NASA Technical Reports Server (NTRS)
Tang, Henry H.; Orndoff, Evelyne S.; Thomas, Gretchen A.
2009-01-01
This paper discusses the effort in evaluating and selecting a light weight impact protection material for the Constellation Space Suit Element (CSSE) Portable Life Support Subsystem (PLSS) conceptual packaging study. A light weight material capable of holding and protecting the components inside the PLSS is required to demonstrate the viability of the flexible PLSS packaging concept. The material needs to distribute, dissipate, and absorb the impact energy of the PLSS falling on the lunar surface. It must also be very robust and function in the extreme lunar thermal vacuum environment for up to one hundred Extravehicular Activity (EVA) missions. This paper documents the performance requirements for selecting a foam protection material, and the methodologies for evaluating commercial off-the-shelf (COTS) foam protection materials. It also presents the materials properties test results and impact drop test results of the various foam materials evaluated in the study. The findings from this study suggest that a foam based flexible protection system is a viable solution for PLSS packaging. However, additional works are needed to optimize COTS foam properties or to develop a composite foam system that will meet all the performance requirements for the CSSE PLSS flexible packaging.
NASA Technical Reports Server (NTRS)
Paul, Heather L.; Jennings, Mallory A.
2009-01-01
The Trace Contaminant Control System (TCCS), located within the ventilation loop of the Portable Life Support System (PLSS) of the Constellation Space Suit Element (CSSE), is responsible for removing hazardous trace contaminants from the space suit ventilation flow. This paper summarizes the results of a trade study that evaluated if trace contaminant control could be accomplished without a TCCS, relying on suit leakage, ullage loss from the carbon dioxide and humidity control system, and other factors. Trace contaminant generation rates were revisited to verify that values reflect the latest designs for CSSE pressure garment materials and PLSS hardware. Additionally, TCCS sizing calculations were performed and a literature survey was conducted to review the latest developments in trace contaminant technologies.
Results of the Trace Contaminant Control Trade Study for Space Suit Life Support Development
NASA Technical Reports Server (NTRS)
Jennings, Mallory A.; Paul, Heather L.
2008-01-01
As the United States plans to return astronauts to the moon, designing the most effective and efficient life support systems is of extreme importance. The trace contaminant control system (TCCS) will be located within the Portable Life Support System (PLSS) of the Constellation Space Suit Element (CSSE), and is responsible for removing contaminants, which at increased levels can be hazardous to a crewmember s health. These contaminants come from several sources including metabolic production of the crewmember (breathing, sweating, etc.) and offgassing of the space suit material layers. This paper summarizes the results of a trade study that investigated TCC technologies used in NASA space suits and vehicles as well as commercial and academic applications, to identify the best technology options for the CSSE PLSS. The trade study also looked at the feasibility of regeneration of TCC technologies, specifically to determine the viability of vacuum regeneration for on-back, realtime EVA.
Results of the Trace Contaminant Control Trade Study for Space Suit Life Support Development
NASA Technical Reports Server (NTRS)
Paul, Heather L.; Jennings, Mallory A.
2009-01-01
As the United States plans to return astronauts to the moon, designing the most effective and efficient life support systems is of extreme importance. The trace contaminant control system (TCCS) will be located within the Portable Life Support System (PLSS) of the Constellation Space Suit Element (CSSE), and is responsible for removing contaminants, which at increased levels can be hazardous to a crewmember's health. These contaminants come from several sources including metabolic production of the crewmember (breathing, sweating, etc.) and offgassing of the space suit material layers. This paper summarizes the results of a trade study that investigated TCC technologies used in NASA space suits and vehicles as well as commercial and academic applications, to identify the best technology options for the CSSE PLSS. The trade study also looked at the feasibility of regeneration of TCC technologies, specifically to determine the viability of vacuum regeneration for on-back, real-time EVA.
Flexible Foam Protection Materials for Portable Life Support System Packaging Study
NASA Technical Reports Server (NTRS)
Tang,Henry H.; Dillon, Paul A.; Thomas, Gretchen A.
2009-01-01
This paper discusses the phase I effort in evaluating and selecting a light weight impact protection material for the Constellation Space Suit Element (CSSE) Portable Life Support System (PLSS) conceptual packaging study. A light weight material capable of holding and protecting the components inside the PLSS is required to demonstrate the viability of the flexible PLSS packaging concept. The material needs to distribute, dissipate, and absorb the impact energy of the PLSS falling on the lunar surface. It must also be robust to consistently perform over several Extravehicular Activity (EVA) missions in the extreme lunar thermal vacuum environment. This paper documents the performance requirements for selecting a foam protection material, and the methodologies for evaluating some commercial off-the-shelf (COTS) foam material candidates. It also presents the mechanical properties and impact drop tests results of the foam material candidates. The results of this study suggest that a foam based flexible protection system is a viable solution for PLSS packaging. However, additional works are needed to optimize COTS foam or to develop a composite foam system that will meet all the performance requirements for the CSSE PLSS flexible packaging.
Flexible Packaging Concept for a Space Suit Portable Life Support Subsystem
NASA Technical Reports Server (NTRS)
Thomas, Gretchen; Dillon, Paul; Oliver, Joe; Zapata, Felipe
2009-01-01
Neither the Shuttle Extravehicular Mobility Unit (EMU), the space suit currently used for space shuttle and International Space Station (ISS) missions, nor the Apollo EMU, the space suit successfully used on previous lunar missions, will satisfy the requirements for the next generation Constellation Program (CxP) lunar suit. The CxP system or Constellation Space Suit Element (CSSE) must be able to tolerate more severe environmental and use conditions than any previous system. These conditions include missions to the severely cold lunar poles and up to 100 Extravehicular Activity (EVA) excursions without ground maintenance. Much effort is focused on decreasing the mass and volume of the Portable Life Support Subsystem (PLSS) over previous suit designs in order to accommodate the required increase in functionality. This paper documents the progress of a conceptual packaging effort of a flexible backpack for the CSSE PLSS. The flexible backpack concept relies on a foam protection system to absorb, distribute, and dissipate the energy from falls on the lunar surface. Testing and analysis of the foam protection system concept that was conducted during this effort indicates that this method of system packaging is a viable solution.
Portable Life Support Subsystem Thermal Hydraulic Performance Analysis
NASA Technical Reports Server (NTRS)
Barnes, Bruce; Pinckney, John; Conger, Bruce
2010-01-01
This paper presents the current state of the thermal hydraulic modeling efforts being conducted for the Constellation Space Suit Element (CSSE) Portable Life Support Subsystem (PLSS). The goal of these efforts is to provide realistic simulations of the PLSS under various modes of operation. The PLSS thermal hydraulic model simulates the thermal, pressure, flow characteristics, and human thermal comfort related to the PLSS performance. This paper presents modeling approaches and assumptions as well as component model descriptions. Results from the models are presented that show PLSS operations at steady-state and transient conditions. Finally, conclusions and recommendations are offered that summarize results, identify PLSS design weaknesses uncovered during review of the analysis results, and propose areas for improvement to increase model fidelity and accuracy.
Implications of Operational Pressure on CSSE PGS Design
NASA Technical Reports Server (NTRS)
Lee, Ryan
2008-01-01
The Constellation Spacesuit Element (CSSE) was required to support crew survival (CS); launch, entry, and abort (LEA) scenarios; zero gravity (0-g) extravehicular activity (EVA) (both unscheduled and contingency); and planetary EVA. Operation of the CSSE in all of these capacities required a pressure garment subsystem (PGS) that would operate efficiently through various pressure profiles. The PGS team initiated a study to determine the appropriate operational pressure profile of the CSSE and how this selection would affect the design of the CSSE PGS. This study included an extensive review of historical PGS operational pressure selection and the operational effects of those pressures, the presentation of four possible pressure paradigm options for use by the CSSE, the risks and design impacts of these options, and the down-selected pressure option.
Regenerative Blower for EVA Suit Ventilation Fan
NASA Technical Reports Server (NTRS)
Izenson, Michael G.; Chen, Weibo; Paul, Heather L.
2010-01-01
Portable life support systems in future space suits will include a ventilation subsystem driven by a dedicated fan. This ventilation fan must meet challenging requirements for pressure rise, flow rate, efficiency, size, safety, and reliability. This paper describes research and development that showed the feasibility of a regenerative blower that is uniquely suited to meet these requirements. We proved feasibility through component tests, blower tests, and design analysis. Based on the requirements for the Constellation Space Suit Element (CSSE) Portable Life Support System (PLSS) ventilation fan, we designed the critical elements of the blower. We measured the effects of key design parameters on blower performance using separate effects tests, and used the results of these tests to design a regenerative blower that will meet the ventilation fan requirements. We assembled a proof-of-concept blower and measured its performance at sub-atmospheric pressures that simulate a PLSS ventilation loop environment. Head/flow performance and maximum efficiency point data were used to specify the design and operating conditions for the ventilation fan. We identified materials for the blower that will enhance safety for operation in a lunar environment, and produced a solid model that illustrates the final design. The proof-of-concept blower produced the flow rate and pressure rise needed for the CSSE ventilation subsystem while running at 5400 rpm, consuming only 9 W of electric power using a non-optimized, commercial motor and controller and inefficient bearings. Scaling the test results to a complete design shows that a lightweight, compact, reliable, and low power regenerative blower can meet the performance requirements for future space suit life support systems.
Results of the Particulate Contamination Control Trade Study for Space Suit Life Support Development
NASA Technical Reports Server (NTRS)
Cognata, Thomas J.; Conger, Bruce; Paul, Heather L.
2009-01-01
As the United States plans to return astronauts to the moon and eventually to Mars, designing the most effective, efficient, and robust space suit life support system that will operate successfully in these dusty environments is vital. There is some knowledge of the contaminants and level of infiltration expected from the Lunar and Mars dust, however risk mitigation strategies and filtration designs to prevent contamination within the space suit life support system are still undefined. A trade study was initiated to identify and address these concerns, and to develop new requirements for the Constellation Space Suit Element (CSSE) Portable Life Support System (PLSS). This trade study investigates historical methods of particulate contamination control in space suits and vehicles, and evaluated the possibility of using commercial technologies for this application. In addition, the trade study examined potential filtration designs. This paper summarizes the results of this trade study.
2013-12-01
include the Command Element (CE), the Aviation Combat Element (ACE), the Ground Combat Element ( GCE ), and the Combat Service Support Element (CSSE) (from...35 Figure 9. The upper level functional architecture for EW12 shows the three primary functions of F1-Assemble the Seabase, F2...Function F2-Perform Assault is decomposed to obtain the lower level specific functions. From this decomposition, the sub-function of F2.2- Gain Entry
Hollow Fiber Space Suit Water Membrane Evaporator Development for Lunar Missions
NASA Technical Reports Server (NTRS)
Bue, Grant C.; Trevino, Luis A.; Hanford, Anthony J.; Mitchell, Keith
2009-01-01
The Space Suit Water Membrane Evaporator (SWME) is the baseline heat rejection technology selected for development for the Constellation lunar suit. The Hollow Fiber (HoFi) SWME is being considered for service in the Constellation Space Suit Element (CSSE) Portable Life Support Subsystem (PLSS) to provide cooling to the thermal loop through water evaporation to the vacuum of space. Previous work described the test methodology and planning to compare the test performance of three commercially available hollow fiber materials as alternatives to the sheet membrane prototype for SWME: 1) porous hydrophobic polypropylene, 2) porous hydrophobic polysulfone, and 3) ion exchange through nonporous hydrophilic modified Nafion. Contamination tests were performed to probe for sensitivities of the candidate SWME elements to organics and non-volative inorganics expected to be found in the target feedwater source, i.e., potable water provided by the vehicle. The resulting presence of precipitate in the coolant water could plug pores and tube channels and affect the SWME performance. From this prior work, a commercial porous hydrophobic hollow fiber was selected to satisfy both the sensitivity question and the need to provide 800 W of heat rejection. This paper describes the trade studies, the design methodology, and the hollow fiber test data used to design a full
2006-09-01
logistical resources necessary to sustain its movement toward assigned objectives while being supported by a CSSE in an expanding maneuver warfare...thesis defines a logistics process and develops a simulation where the GCE consumes logistical resources necessary to sustain its movement toward...the MAGTF is responsible for responding to the logistics needs of the MAGTF Ground Combat Element (GCE) in order to sustain its movement. Yet
Results and Analysis from Space Suit Joint Torque Testing
NASA Technical Reports Server (NTRS)
Matty, Jennifer
2010-01-01
A space suit's mobility is critical to an astronaut's ability to perform work efficiently. As mobility increases, the astronaut can perform tasks for longer durations with less fatigue. Mobility can be broken down into two parts: range of motion (ROM) and torque. These two measurements describe how the suit moves and how much force it takes to move. Two methods were chosen to define mobility requirements for the Constellation Space Suit Element (CSSE). One method focuses on range of motion and the second method centers on joint torque. A joint torque test was conducted to determine a baseline for current advanced space suit joint torques. This test utilized the following space suits: Extravehicular Mobility Unit (EMU), Advanced Crew Escape Suit (ACES), I-Suit, D-Suit, Enhanced Mobility (EM)- ACES, and Mark III (MK-III). Data was collected data from 16 different joint movements of each suit. The results were then reviewed and CSSE joint torque requirement values were selected. The focus of this paper is to discuss trends observed during data analysis.
Spacesuit Water Membrane Evaporator Development for Lunar Missions
NASA Technical Reports Server (NTRS)
Vogel, Matt R.; Peterson, Keith; Zapata, Felipe, III; Dillon, Paul; Trevino, Luis A.
2008-01-01
For future lunar extra-vehicular activities (EVA), one method under consideration for rejecting crew and electronics heat involves evaporating water through a hydrophobic, porous Teflon membrane. A Spacesuit Water Membrane Evaporator (SWME) prototype using the Teflon membrane was tested successfully by Ungar and Thomas (2001) with predicted performance matching test data well. The above referenced work laid the foundation for the design of the SWME development unit, which is being considered for service in the Constellation System Spacesuit Element (CSSE) Portable Life Support System (PLSS). Multiple PLSS SWME configurations were considered on the basis of thermal performance, mass, volume, and performance and manufacturing risk. All configurations were a variation of an alternating concentric water and vapor channel configuration or a stack of alternating rectangular water and vapor channels. Supporting thermal performance trades mapped maximum SWME heat rejection as a function of water channel thickness, vapor channel thickness, channel length, number of water channels, porosity of the membrane structural support, and backpressure valve throat area. Preliminary designs of each configuration were developed to determine total mass and volume as well as to understand manufacturing issues. Review of configurations led to the selection of a concentric annulus configuration that meets the requirements of 800 watts (W) of heat rejection. Detailed design of the SWME development unit will be followed by fabrication of a prototype test unit, with thermal testing expected to start in 2008.
Processing multilevel secure test and evaluation information
NASA Astrophysics Data System (ADS)
Hurlburt, George; Hildreth, Bradley; Acevedo, Teresa
1994-07-01
The Test and Evaluation Community Network (TECNET) is building a Multilevel Secure (MLS) system. This system features simultaneous access to classified and unclassified information and easy access through widely available communications channels. It provides the necessary separation of classification levels, assured through the use of trusted system design techniques, security assessments and evaluations. This system enables cleared T&E users to view and manipulate classified and unclassified information resources either using a single terminal interface or multiple windows in a graphical user interface. TECNET is in direct partnership with the National Security Agency (NSA) to develop and field the MLS TECNET capability in the near term. The centerpiece of this partnership is a state-of-the-art Concurrent Systems Security Engineering (CSSE) process. In developing the MLS TECNET capability, TECNET and NSA are providing members, with various expertise and diverse backgrounds, to participate in the CSSE process. The CSSE process is founded on the concepts of both Systems Engineering and Concurrent Engineering. Systems Engineering is an interdisciplinary approach to evolve and verify an integrated and life cycle balanced set of system product and process solutions that satisfy customer needs (ASD/ENS-MIL STD 499B 1992). Concurrent Engineering is design and development using the simultaneous, applied talents of a diverse group of people with the appropriate skills. Harnessing diverse talents to support CSSE requires active participation by team members in an environment that both respects and encourages diversity.
Closed System Step Etching of CI chondrite Ivuna reveals primordial noble gases in the HF-solubles
NASA Astrophysics Data System (ADS)
Riebe, My E. I.; Busemann, Henner; Wieler, Rainer; Maden, Colin
2017-05-01
We analyzed all the noble gases in HF-soluble phases in the CI chondrite Ivuna by in-vacuum gas release using the "Closed System Step Etching" (CSSE) technique, which allows for direct noble gas measurements of acid-soluble phases. The main motivation was to investigate if there are primordial noble gases in HF-soluble phases in Ivuna, something that has not been done before in CI chondrites, as most primordial noble gases are known to reside in HF-resistant phases. The first steps under mild etching released He, Ne, and Ar with solar-like elemental and isotopic compositions, confirming that Ivuna contains implanted solar wind (SW) noble gases acquired in the parent body regolith. The SW component released in some etch steps was elementally unfractionated. This is unusual as trapped SW noble gases are elementally fractionated in most meteoritic material. In the intermediate etch steps under slightly harsher etching, cosmogenic noble gases were more prominent than SW noble gases. The HF-soluble portion of Ivuna contained primordial Ne and Xe, that was most visible in the last etch steps after all cosmogenic and most SW gases had been released. The primordial Ne and Xe in the HF-solubles have isotopic and elemental ratios readily explained as a mixture of the two most abundant primordial noble gas components in Ivuna bulk samples: HL and Q. Only small fractions of the total HL and Q in Ivuna were released during CSSE analysis; ∼3% of 20NeHL and ∼4% of 132XeQ. HL is known to reside in nanodiamond-rich separates and Q-gases are most likely carried by a carbonaceous phase known as phase Q. Q-gases were likely released from an HF-soluble portion of phase Q. However, nanodiamonds might not be the source of the HL-gases released upon etching, since nanodiamond-rich separates are very HF-resistant and the less tightly bound nanodiamond component P3 was not detected.
3D stromal tissue equivalent affects intestinal epithelium morphogenesis in vitro.
De Gregorio, Vincenza; Imparato, Giorgia; Urciuolo, Francesco; Netti, Paolo A
2018-04-01
Current in vitro models of human intestine commonly fail to mimic the complex intestinal functions and features required for drug development and disease research. Here, we deeply investigate the interaction existing between epithelium and the underneath stroma, and its role in the epithelium morphogenesis. We cultured human intestinal subepithelial myofibroblasts (ISEMFs) in two different 3D configurations: 3D-collagen gel equivalent (3D-CGE) and 3D cell-synthetized stromal equivalent (3D-CSSE). The 3D-CGEs were obtained by means of the traditional collagen-based cell technique and the 3D-CSSE were obtained by bottom-up tissue engineering strategy. The biophysical properties of both 3D models with regard to cell growth and composition (via histological analysis, immunofluorescence, and multiphoton imaging) were assessed. Then, human colorectal adenocarcinoma cell line (CaCo-2) was cultured on both the 3D constructs in order to produce the intestinal model. We identified higher levels of matrix-associated proteins from ISEMFs cultured in 3D-CSSE compared to 3D-CGE. Furthermore, multiphoton investigation revealed differences in the collagen network architecture in both models. At last, the more physiologically relevant stromal environment of the 3D-CSSE drove the CaCo-2 cell differentiation toward the four different type of intestinal epithelial cells (absorptive, mucus-secretory, enteroendocrine, and Paneth) phenotype and promotes, in contrast to the 3D-CGE, the production of the basement membrane. Taken together, these results highlight a fundamental role of the 3D stromal environment in addressing a correct epithelium morphogenesis as well as epithelial-stromal interface establishment. © 2017 Wiley Periodicals, Inc.
A long-term change of the AR/KR/XE fractionation in the solar corpuscular radiation
NASA Technical Reports Server (NTRS)
Wieler, R.; Baur, H.; Signer, P.
1993-01-01
Solar noble gases in an ilmenite separate from breccia 79035 (antiquity greater than 1 Ga) were analyzed by closed system stepped etching (CSSE). All five gases show the familiar two-component structure: first solar-wind (SW) gases are released, followed by gases from solar energetic particles (SEP). Element patterns in 79035 are similar to those of 71501 ilmenite. SW-He-Ne were partly lost, but SEP-He-Ne-Ar are retained (nearly) unfractionated. Constant Ar/Kr/Xe ratios indicate that ilmenites contain an unfractionated sample of the heavy SW-SEP noble gases. Ar/Kr/Xe ratios in the solar corpuscular radiation are, however, different from 'solar system' values, whereby the Kr/Xe difference in 79035 is about twice as large as in 71501. We propose that Xe is less fractionated than Kr and Ar, though its first ionization potential (FIP) is higher than the 'cutoff' at approximately 11.5 eV, above which all elements in SEP are usually assumed to be depleted by a roughly constant factor. SW-Ne may be isotopically slightly heavier in the ancient SW trapped by 79035, as proposed earlier. In this work we extend our previous CSSE studies of solar noble gases including Kr and Xe to a lunar sample irradiated at least 1 Ga ago (breccia 79035, ilmenite separate, 42-64 microns). This sample was particularly gently etched in the first steps. Surprisingly, the first three steps, each releasing less than or equal to 0.5% of the total 36-Ar, showed an SEP-like trapped component plus relatively large concentrations of cosmogenic gases. Steps 4ff contain much less cosmogenic and more solar gas with a SW-like isotope pattern. Thus, a very minor easily etchable phase that has completely lost its SW-gases must be responsible for steps 1-3. We will not discuss these steps here and refer to the actual step 4 as the 'initial' etching step.
Vázquez Pérez, María Luisa; Godoy-Izquierdo, Débora; Godoy, Juan F
2013-03-01
This study evaluated the clinical effects of an intervention aimed at enhancing specific self-efficacy for coping with stress (CSSE) among patients with psychosis. Fourteen patients, 21-60 years old, diagnosed with schizophrenia or schizoaffective disorder voluntarily participated and were randomly assigned to a training and a control group. The Brief Psychiatric Rating Scale-24 was used to assess psychotic symptoms (primary outcomes) at baseline, post-intervention, and three- and six-month follow-ups. The participants also completed self-reports on well-being and satisfaction with intervention outcomes (secondary outcomes) at post-intervention and at the two follow-up assessments. Trained patients showed a significant decrease in all measures of psychotic symptoms (for disorientation, not significant (NS); effect sizes up to d=4.80). This decline in symptoms remained significant at the follow-ups, with clinical enhancements on some of the subscales. By contrast, control participants showed no significant change in their symptoms. Short- and long-term overall well-being and satisfaction with outcomes were higher among the participants who received the training program. Our findings point out the relevance of enhancing CSSE among patients with psychosis, along with enhancing their coping skills for managing their illness. We conclude that CSSE training should be considered in future therapeutic interventions for psychotic disorders.
2016 CSSE L3 Milestone: Deliver In Situ to XTD End Users
DOE Office of Scientific and Technical Information (OSTI.GOV)
Patchett, John M.; Nouanesengsy, Boonthanome; Fasel, Patricia Kroll
This report summarizes the activities in FY16 toward satisfying the CSSE 2016 L3 milestone to deliver in situ to XTD end users of EAP codes. The Milestone was accomplished with ongoing work to ensure the capability is maintained and developed. Two XTD end users used the in situ capability in Rage. A production ParaView capability was created in the HPC and Desktop environment. Two new capabilities were added to ParaView in support of an EAP in situ workflow. We also worked with various support groups at the lab to deploy a production ParaView in the LANL environment for both desktopmore » and HPC systems. . In addition, for this milestone, we moved two VTK based filters from research objects into the production ParaView code to support a variety of standard visualization pipelines for our EAP codes.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kunimura, Shinsuke; Hatakeyama, So; Sasaki, Nobuharu
A portable total reflection X-ray fluorescence (TXRF) spectrometer that we have developed is applied to trace elemental analysis of water solutions. Although a 5 W X-ray tube is used in the portable TXRF spectrometer, detection limits of several ppb are achieved for 3d transition metal elements and trace elements in a leaching solution of soils, a leaching solution of solder, and alcoholic beverages are detected. Portable X-ray fluorescence (XRF) spectromicroscopes with a 1 W X-ray tube and an 8 W X-ray tube are also presented. Using the portable XRF spectromicroscope with the 1 W X-ray tube, 93 ppm of Crmore » is detected with an about 700 {mu}m spatial resolution. Spatially resolved elemental analysis of a mug painted with blue, red, green, and white is performed using the two portable spectromicroscopes, and the difference in elemental composition at each paint is detected.« less
Science Teaching in Science Education
ERIC Educational Resources Information Center
Callahan, Brendan E.; Dopico, Eduardo
2016-01-01
Reading the interesting article "Discerning selective traditions in science education" by Per Sund, which is published in this issue of "CSSE," allows us to open the discussion on procedures for teaching science today. Clearly there is overlap between the teaching of science and other areas of knowledge. However, we must…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hoekstra, Robert J.; Hammond, Simon David; Hemmert, Karl Scott
The presentation documented the technical approach of the team and summary of the results with sufficient detail to demonstrate both the value and the completion of the milestone. A separate SAND report was also generated with more detail to supplement the presentation.
FY17 ASC CSSE L2 Milestone 6018: Power Usage Characteristics of Workloads Running on Trinity.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pedretti, Kevin
The overall goal of this work was to utilize the Advanced Power Management (APM) capabilities of the ATS-1 Trinity platform to understand the power usage behavior of ASC workloads running on Trinity and gain insight into the potential for utilizing power management techniques on future ASC platforms.
ERIC Educational Resources Information Center
Clarke, Marlon
2011-01-01
As organizations have become more dependent on networked information systems (IS) to conduct their business operations, their susceptibility to various threats to information security has also increased. Research has consistently identified the inappropriate security behavior of the users as the most significant of these threats. Various factors…
1984-07-12
with Special Needs (8) Child Abuse /Neglect (9) Guidance for Establishing Babysitting Co-ops A 1. Purpose. To provide policy and guidance for the...guidance techniques; and (12) reporting child abuse (enclosure (8)). 0 Each caregiver without a nationally recognized child development credential...authority of reportable communicable diseases, child abuse and child neglect. (6) Establishment of criteria on a case by csse basis for
Suited Occupant Injury Potential During Dynamic Spacecraft Flight Phases
NASA Technical Reports Server (NTRS)
Dub, Mark O.; McFarland, Shane M.
2010-01-01
In support of the Constellation Space Suit Element [CSSE], a new space-suit architecture will be created for support of Launch, Entry, Abort, Microgravity Extra- Vehicular Activity [EVA], and post-landing crew operations, safety and, under emergency conditions, survival. The space suit is unique in comparison to previous launch, entry, and abort [LEA] suit architectures in that it utilizes rigid mobility elements in the scye (i.e., shoulder) and the upper arm regions. The suit architecture also utilizes rigid thigh disconnect elements to create a quick disconnect approximately located above the knee. This feature allows commonality of the lower portion of the suit (from the thigh disconnect down), making the lower legs common across two suit configurations. This suit must interface with the Orion vehicle seat subsystem, which includes seat components, lateral supports, and restraints. Due to the unique configuration of spacesuit mobility elements, combined with the need to provide occupant protection during dynamic vehicle events, risks have been identified with potential injury due to the suit characteristics described above. To address the risk concerns, a test series has been developed in coordination with the Injury Biomechanics Research Laboratory [IBRL] to evaluate the likelihood and consequences of these potential issues. Testing includes use of Anthropomorphic Test Devices [ATDs; vernacularly referred to as "crash test dummies"], Post Mortem Human Subjects [PMHS], and representative seat/suit hardware in combination with high linear acceleration events. The ensuing treatment focuses on test purpose and objectives; test hardware, facility, and setup; and preliminary results.
ERIC Educational Resources Information Center
Fisher, Donald
2017-01-01
In this commentary, Donald Fisher reports on the history of the "The Canadian Journal of Education" as part of this 40th anniversary issue. Fisher states that the history of the Canadian Society for the Study of Education (CSSE) has been profoundly influenced by changes in the role of the Canadian State. The 1960s and 1970s were a time…
Development of a Compact Efficient Cooling Pump for Space Suit Life Support Systems
NASA Technical Reports Server (NTRS)
vanBoeyen, Roger W.; Reeh, Jonathan A.; Trevino, Luis
2008-01-01
With the increasing demands placed on extravehicular activity (EVA) for the International Space Station (ISS) assembly and maintenance, along with planned lunar and Martian missions, the need for increased human productivity and capability becomes ever more critical. This is most readily achieved by reduction in space suit weight and volume, and increased hardware reliability, durability, and operating lifetime. Considerable progress has been made with each successive generation of space suit design; from the Apollo A7L suit, to the current Shuttle Extravehicular Mobile Unit (EMU) suit, and the next generation Constellation Space Suit Element (CSSE). However, one area of space suit design which has continued to lag is the fluid pump used to drive the water cooling loop of the Primary Life Support System (PLSS). The two main types of fluid pumps typically used in space applications are rotodynamic pumps (pumping is achieved through a rotary vaned impeller) and displacement pumps (which includes rotary and diaphragm pumps). The rotating and moving parts found in the pumps and electric motor add significantly to the susceptibility to wear and friction, thermal mismatch, and complexity of the pumps. Electric motor-driven pumps capable of achieving high operational reliability are necessarily large, heavy, and energy inefficient. This report describes a development effort conducted for NASA by Lynntech, Inc., who recently demonstrated the feasibility of an electrochemically-driven fluid cooling pump. With no electric motor and minimal lightweight components, an electrochemically-driven pump is expected to be significantly smaller, lighter and achieve a longer life time than conventional rotodynamic and displacement pumps. By employing sulfonated polystyrene-based proton exchange membranes, rather than conventional Nafion membranes, a significant reduction in the actuator power consumption was demonstrated. It was also demonstrated that these membranes possess the necessary mechanical strength, durability, and temperature range for long life space operation. The preliminary design for a Phase II prototype pump compares very favorably to the fluid cooling pumps currently used in space suit portable life support systems (PLSS). Characteristics of the electrochemically-driven pump are described and the benefits of the technology as a replacement for electric motor pumps in mechanically pumped single-phase fluid loops (MPFLs) is discussed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Curry, Matthew L.; Ferreira, Kurt Brian; Pedretti, Kevin Thomas Tauke
2012-03-01
This report documents thirteen of Sandia's contributions to the Computational Systems and Software Environment (CSSE) within the Advanced Simulation and Computing (ASC) program between fiscal years 2009 and 2012. It describes their impact on ASC applications. Most contributions are implemented in lower software levels allowing for application improvement without source code changes. Improvements are identified in such areas as reduced run time, characterizing power usage, and Input/Output (I/O). Other experiments are more forward looking, demonstrating potential bottlenecks using mini-application versions of the legacy codes and simulating their network activity on Exascale-class hardware. The purpose of this report is to provemore » that the team has completed milestone 4467-Demonstration of a Legacy Application's Path to Exascale. Cielo is expected to be the last capability system on which existing ASC codes can run without significant modifications. This assertion will be tested to determine where the breaking point is for an existing highly scalable application. The goal is to stretch the performance boundaries of the application by applying recent CSSE RD in areas such as resilience, power, I/O, visualization services, SMARTMAP, lightweight LWKs, virtualization, simulation, and feedback loops. Dedicated system time reservations and/or CCC allocations will be used to quantify the impact of system-level changes to extend the life and performance of the ASC code base. Finally, a simulation of anticipated exascale-class hardware will be performed using SST to supplement the calculations. Determine where the breaking point is for an existing highly scalable application: Chapter 15 presented the CSSE work that sought to identify the breaking point in two ASC legacy applications-Charon and CTH. Their mini-app versions were also employed to complete the task. There is no single breaking point as more than one issue was found with the two codes. The results were that applications can expect to encounter performance issues related to the computing environment, system software, and algorithms. Careful profiling of runtime performance will be needed to identify the source of an issue, in strong combination with knowledge of system software and application source code.« less
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-30
... elemental mercury in portable battery-powered motor-aspirated psychrometers that contain fewer than seven... United States. That one type is a portable, battery-powered, motor-aspirated psychrometer containing less..., distribution in commerce, use, and waste management (landfilling or recycling). At any point in the lifecycle...
NASA Astrophysics Data System (ADS)
Pappalardo, L.; Karydas, A. G.; Kotzamani, N.; Pappalardo, G.; Romano, F. P.; Zarkadas, Ch.
2005-09-01
Gemstones on gold Hellenistic (late 4th century BC, 1st AD) jewelry, exhibited at the Benaki Museum of Athens, were analyzed in situ by means of two non-destructive and portable analytical techniques. The composition of major and minor elements was determined using a new portable PIXE-alpha spectrometer. The analytical features of this spectrometer allow the determination of matrix elements from Na to Zn through the K-lines and the determination of higher atomic number elements via the L- or M-lines. The red stones analyzed were revealed as red garnets, displaying a compositional range from Mg-rich garnet to Fe-rich garnet. The complementary use of a portable XRF spectrometer provided additional information on some trace elements (Cr and Y), which are considered to be important for the chemical separation between different garnet groups. A comparison of our results with recent literature data offers useful indications about the possible geographical provenance of the stones. The analytical techniques, their complementarity and the results obtained are presented and discussed.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-06
... service as of the publication date of this proposed rule and mercury use in portable battery-powered motor... proposal is the ongoing use of mercury in the manufacture, import, or processing of portable battery.... That one type is a portable battery-powered motor-aspirated psychrometer containing fewer than seven...
2016-06-01
an effective system monitoring and display capability. The SOM, C-SSE, and resource managers access MUOS via a web portal called the MUOS Planning...and Provisioning Application (PlanProvApp). This web portal is their window into MUOS and is designed to provide them with a shared understanding of...including page loading errors, partially loaded web pages, incomplete reports, and inaccurate reports. For example, MUOS reported that there were
Facile synthesis of CsPbBr3/PbSe composite clusters
Nguyen, Thang Phan; Ozturk, Abdullah; Park, Jongee; Sohn, Woonbae; Lee, Tae Hyung; Jang, Ho Won; Kim, Soo Young
2018-01-01
Abstract In this work, CsPbBr3 and PbSe nanocomposites were synthesized to protect perovskite material from self-enlargement during reaction. UV absorption and photoluminescence (PL) spectra indicate that the addition of Se into CsPbBr3 quantum dots modified the electronic structure of CsPbBr3, increasing the band gap from 2.38 to 2.48 eV as the Cs:Se ratio increased to 1:3. Thus, the emission color of CsPbBr3 perovskite quantum dots was modified from green to blue by increasing the Se ratio in composites. According to X-ray diffraction patterns, the structure of CsPbBr3 quantum dots changed from cubic to orthorhombic due to the introduction of PbSe at the surface. Transmission electron microscopy and X-ray photoemission spectroscopy confirmed that the atomic distribution in CsPbBr3/PbSe composite clusters is uniform and the composite materials were well formed. The PL intensity of a CsPbBr3/PbSe sample with a 1:1 Cs:Se ratio maintained 50% of its initial intensity after keeping the sample for 81 h in air, while the PL intensity of CsPbBr3 reduced to 20% of its initial intensity. Therefore, it is considered that low amounts of Se could improve the stability of CsPbBr3 quantum dots. PMID:29296127
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pedretti, Kevin
This report summarizes the work performed as part of a FY17 CSSE L2 milestone to in- vestigate the power usage behavior of ASC workloads running on the ATS-1 Trinity plat- form. Techniques were developed to instrument application code regions of interest using the Power API together with the Kokkos profiling interface and Caliper annotation library. Experiments were performed to understand the power usage behavior of mini-applications and the SNL/ATDM SPARC application running on ATS-1 Trinity Haswell and Knights Landing compute nodes. A taxonomy of power measurement approaches was identified and presented, providing a guide for application developers to follow. Controlledmore » scaling study experiments were performed on up to 2048 nodes of Trinity along with smaller scale ex- periments on Trinity testbed systems. Additionally, power and energy system monitoring information from Trinity was collected and archived for post analysis of "in-the-wild" work- loads. Results were analyzed to assess the sensitivity of the workloads to ATS-1 compute node type (Haswell vs. Knights Landing), CPU frequency control, node-level power capping control, OpenMP configuration, Knights Landing on-package memory configuration, and algorithm/solver configuration. Overall, this milestone lays groundwork for addressing the long-term goal of determining how to best use and operate future ASC platforms to achieve the greatest benefit subject to a constrained power budget.« less
Portable modular detection system
Brennan, James S [Rodeo, CA; Singh, Anup [Danville, CA; Throckmorton, Daniel J [Tracy, CA; Stamps, James F [Livermore, CA
2009-10-13
Disclosed herein are portable and modular detection devices and systems for detecting electromagnetic radiation, such as fluorescence, from an analyte which comprises at least one optical element removably attached to at least one alignment rail. Also disclosed are modular detection devices and systems having an integrated lock-in amplifier and spatial filter and assay methods using the portable and modular detection devices.
Toward performance portability of the Albany finite element analysis code using the Kokkos library
DOE Office of Scientific and Technical Information (OSTI.GOV)
Demeshko, Irina; Watkins, Jerry; Tezaur, Irina K.
Performance portability on heterogeneous high-performance computing (HPC) systems is a major challenge faced today by code developers: parallel code needs to be executed correctly as well as with high performance on machines with different architectures, operating systems, and software libraries. The finite element method (FEM) is a popular and flexible method for discretizing partial differential equations arising in a wide variety of scientific, engineering, and industrial applications that require HPC. This paper presents some preliminary results pertaining to our development of a performance portable implementation of the FEM-based Albany code. Performance portability is achieved using the Kokkos library. We presentmore » performance results for the Aeras global atmosphere dynamical core module in Albany. Finally, numerical experiments show that our single code implementation gives reasonable performance across three multicore/many-core architectures: NVIDIA General Processing Units (GPU’s), Intel Xeon Phis, and multicore CPUs.« less
Toward performance portability of the Albany finite element analysis code using the Kokkos library
Demeshko, Irina; Watkins, Jerry; Tezaur, Irina K.; ...
2018-02-05
Performance portability on heterogeneous high-performance computing (HPC) systems is a major challenge faced today by code developers: parallel code needs to be executed correctly as well as with high performance on machines with different architectures, operating systems, and software libraries. The finite element method (FEM) is a popular and flexible method for discretizing partial differential equations arising in a wide variety of scientific, engineering, and industrial applications that require HPC. This paper presents some preliminary results pertaining to our development of a performance portable implementation of the FEM-based Albany code. Performance portability is achieved using the Kokkos library. We presentmore » performance results for the Aeras global atmosphere dynamical core module in Albany. Finally, numerical experiments show that our single code implementation gives reasonable performance across three multicore/many-core architectures: NVIDIA General Processing Units (GPU’s), Intel Xeon Phis, and multicore CPUs.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Roy, Tushar, E-mail: tushar@barc.gov.in; Kashyap, Yogesh; Shukla, Mayank
Associated particle technique (APT) for detection of explosives is well established but has been implemented mostly for fixed portal systems. In certain situations, a portable system is required where the suspect object cannot be moved from site. This paper discusses the development of a portable APT system in single-sided geometry which can be transported to site and requires only one-sided access to the object. The system comprised D-T neutron source and bismuth germanate (BGO) detectors fixed on a portable module. Different aspects of the system have been discussed such as background contribution, time selection, and elemental signatures. The system wasmore » used to detect benign samples and explosive simulants under laboratory condition. The elemental ratios obtained by analyzing the gamma spectra show good match with the theoretical ratios.« less
NASA Technical Reports Server (NTRS)
Mckay, Charles W.; Feagin, Terry; Bishop, Peter C.; Hallum, Cecil R.; Freedman, Glenn B.
1987-01-01
The principle focus of one of the RICIS (Research Institute for Computing and Information Systems) components is computer systems and software engineering in-the-large of the lifecycle of large, complex, distributed systems which: (1) evolve incrementally over a long time; (2) contain non-stop components; and (3) must simultaneously satisfy a prioritized balance of mission and safety critical requirements at run time. This focus is extremely important because of the contribution of the scaling direction problem to the current software crisis. The Computer Systems and Software Engineering (CSSE) component addresses the lifestyle issues of three environments: host, integration, and target.
ERIC Educational Resources Information Center
Marshall, James L.
2000-01-01
Introduces a portable and permanent set of the elemental collection including 87 samples of elements which are, minimum, one gram or more. Demonstrates radioactivity, magnetism, fluorescence, melting solids, spectral analysis, and conduction of heat. Includes a display of minerals associated with the elements. (YDS)
Develop real-time dosimetry concepts and instrumentation for long term missions
NASA Technical Reports Server (NTRS)
Braby, L. A.
1982-01-01
The development of a rugged portable instrument to evaluate dose and dose equivalent is described. A tissue-equivalent proportional counter simulating a 2 micrometer spherical tissue volume was operated satisfactorily for over a year. The basic elements of the electronic system were designed and tested. And finally, the most suitable mathematical technique for evaluating dose equivalent with a portable instrument was selected. Design and fabrication of a portable prototype, based on the previously tested circuits, is underway.
Aeras: A next generation global atmosphere model
Spotz, William F.; Smith, Thomas M.; Demeshko, Irina P.; ...
2015-06-01
Sandia National Laboratories is developing a new global atmosphere model named Aeras that is performance portable and supports the quantification of uncertainties. These next-generation capabilities are enabled by building Aeras on top of Albany, a code base that supports the rapid development of scientific application codes while leveraging Sandia's foundational mathematics and computer science packages in Trilinos and Dakota. Embedded uncertainty quantification (UQ) is an original design capability of Albany, and performance portability is a recent upgrade. Other required features, such as shell-type elements, spectral elements, efficient explicit and semi-implicit time-stepping, transient sensitivity analysis, and concurrent ensembles, were not componentsmore » of Albany as the project began, and have been (or are being) added by the Aeras team. We present early UQ and performance portability results for the shallow water equations.« less
NASA Astrophysics Data System (ADS)
Suresh, Pooja
2014-05-01
Alloy identification of oil-borne wear debris captured on chip detectors, filters and magnetic plugs allows the machinery maintainer to assess the health of the engine or gearbox and identify specific component damage. Today, such identification can be achieved in real time using portable, at-line laser-induced breakdown spectroscopy (LIBS) and Xray fluorescence (XRF) instruments. Both techniques can be utilized in various industries including aviation, marine, railways, heavy diesel and other industrial machinery with, however, some substantial differences in application and instrument performance. In this work, the performances of a LIBS and an XRF instrument are compared based on measurements of a wide range of typical aerospace alloys including steels, titanium, aluminum and nickel alloys. Measurement results were analyzed with a staged correlation technique specifically developed for the purposes of this study - identifying the particle alloy composition using a pre-recorded library of spectral signatures. The analysis is performed in two stages: first, the base element of the alloy is determined by correlation with the stored elemental spectra and then, the alloy is identified by matching the particle's spectral signature using parametric correlation against the stored spectra of all alloys that have the same base element. The correlation analysis has achieved highly repeatable discrimination between alloys of similar composition. Portable LIBS demonstrates higher detection accuracy and better identification of alloys comprising lighter elements as compared to that of the portable XRF system, and reveals a significant reduction in the analysis time over XRF.
NASA Astrophysics Data System (ADS)
Pappalardo, L.; Bracchitta, D.; Palio, O.; Pappalardo, G.; Rizzo, F.
2012-04-01
About 1300 obsidian artefacts coming from various archaeological sites of Sicily were analyzed by using the BSC-XRF (Beam Stability Controlled - X-ray Fluorescence) and PIXE-alpha (Particle Induced X-ray Emission, using low energy alpha particles) portable spectrometers developed at the Landis laboratory at the LNS-INF and IBAM-CNR in Catania (Italy). The portable BSC-XRF system allows the non-destructive analysis of the Rb, Sr, Y, Zr and Nb trace concentrations, which are considered to be characteristic of the obsidian samples and consequently are indicative of the provenance quarries. Quantitative data on Rb, Sr, Y, Zr, Nb trace element concentrations where deduced through the use of a method that makes use of a multi parameter linear regression, previously The portable PIXE-alpha spectrometer allows the quantitative determination of the matrix major elements, from Na to Zn. In the present work the two instrumental devices are presented. The data are from: Milena (Cl), Ustica (Pa), Rocchicella (Ct), Poggio dell'Acquila (Ct), San Marco (Ct), Villaggio del Petraro* (Sr) and Licodia Eubea* (Ct). Results on compositional data for trace elements and major elements allowed to identify Lipari and Pantelleria islands as the only two sources of the analysed samples. Analyses carried out on vitreous artefact found in Rocchicella, showed for the first time that the Palagonite was used as row material. *Preliminary data. Topic of conference: Application of XRS in archaeometry Kind of presentation: oral
Weagant, Scott; Chen, Vivian; Karanassios, Vassili
2011-11-01
A battery-operated, atmospheric pressure, self-igniting, planar geometry Ar-H(2) microplasma for elemental analysis of liquid microsamples is described. The inexpensive microplasma device (MPD) fabricated for this work was a hybrid plastic-quartz structure that was formed on chips with an area (roughly) equal to that of a small-sized postage stamp (MPD footprint, 12.5-mm width by 38-mm length). Plastic substrates were chosen due to their low cost, for rapid prototyping purposes, and for a speedy microplasma device evaluation. To enhance portability, the microplasma was operated from an 18-V rechargeable battery. To facilitate portability even further, it was demonstrated that the battery can be recharged by a portable solar panel. The battery-supplied dc voltage was converted to a high-voltage ac. The ~750-μm (diameter) and 12-mm (long) Ar-H(2) (3% H(2)) microplasma was formed by applying the high-voltage ac between two needle electrodes. Spectral interference from the electrode materials or from the plastic substrate was not observed. Operating conditions were found to be key to igniting and sustaining a microplasma that was simply "warm" to the touch (thus alleviating the need for cooling or other thermal management) and that had a stable background emission. A small-sized (900 μL internal volume) electrothermal vaporization system (40-W max power) was used for microsample introduction. Microplasma background emission in the spectral region between 200 and 850 nm obtained using a portable fiber-optic spectrometer is reported and the effect of the operating conditions is described. Analyte emission from microliter volumes of dilute single-element standard solutions of Cd, Cu, K, Li, Mg, Mn, Na, Pb, and Zn is documented. The majority of spectral lines observed for the elements tested were from neutral atoms. The relative lack of emission from ion lines simplified the spectra, thus facilitating the use of a portable spectrometer. Despite the relative spectral simplicity, some spectral interference effects were noted when running a multi-element solution. An example of how interference in the spectral domain can be resolved in the time domain using selective thermal vaporization is provided. Analytical utility and performance characteristics are reported; for example, K concentrations in diluted (~30 times) bottled water were determined to be 4.1 ± 1.0 μg/mL (4 μg/mL was the stated concentration), precision was about 25%, and the estimated detection limits were in the picogram range (or in nanograms per milliliter in relative units).
Water quality monitor (EMPAX instrument)
NASA Technical Reports Server (NTRS)
Kelliher, Warren C.; Clark, Ben; Thornton, Mike
1991-01-01
The impetus of the Viking Mission to Mars led to the first miniaturization of a X-ray Fluorescence Spectrometer (XRFS). Two units were flown on the Viking Mission and successfully operated for two years analyzing the elemental composition of the Martian soil. Under a Bureau of Mines/NASA Technology Utilization project, this XRFS design was utilized to produce a battery powered, portable unit for elemental analysis of geological samples. This paper will detail design improvements and additional sampling capabilities that were incorporated into a second generation portable XRFS that was funded by the EPA/NASA Technology Utilization project. The unit, Environment Monitoring with Portable Analysis by X-ray (EMPAX), was developed specifically for quantitative determination of the need of EPA and and any industry affected by environmental concerns, the EMPAX fulfills a critical need to provide on-site, real-time analysis of toxic metal contamination. A patent was issued on EMPAX, but a commercial manufacturer is still being sought.
(U) Ristra Next Generation Code Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hungerford, Aimee L.; Daniel, David John
LANL’s Weapons Physics management (ADX) and ASC program office have defined a strategy for exascale-class application codes that follows two supportive, and mutually risk-mitigating paths: evolution for established codes (with a strong pedigree within the user community) based upon existing programming paradigms (MPI+X); and Ristra (formerly known as NGC), a high-risk/high-reward push for a next-generation multi-physics, multi-scale simulation toolkit based on emerging advanced programming systems (with an initial focus on data-flow task-based models exemplified by Legion [5]). Development along these paths is supported by the ATDM, IC, and CSSE elements of the ASC program, with the resulting codes forming amore » common ecosystem, and with algorithm and code exchange between them anticipated. Furthermore, solution of some of the more challenging problems of the future will require a federation of codes working together, using established-pedigree codes in partnership with new capabilities as they come on line. The role of Ristra as the high-risk/high-reward path for LANL’s codes is fully consistent with its role in the Advanced Technology Development and Mitigation (ATDM) sub-program of ASC (see Appendix C), in particular its emphasis on evolving ASC capabilities through novel programming models and data management technologies.« less
NASA Astrophysics Data System (ADS)
Guimarães, Diana; Praamsma, Meredith L.; Parsons, Patrick J.
2016-08-01
X-ray fluorescence spectrometry (XRF) is a rapid, non-destructive multi-elemental analytical technique used for determining elemental contents ranging from percent down to the μg/g level. Although detection limits are much higher for XRF compared to other laboratory-based methods, such as inductively coupled plasma mass spectrometry (ICP-MS), ICP-optical emission spectrometry (OES) and atomic absorption spectrometry (AAS), its portability and ease of use make it a valuable tool, especially for field-based studies. A growing necessity to monitor human exposure to toxic metals and metalloids in consumer goods, cultural products, foods and other sample types while performing the analysis in situ has led to several important developments in portable XRF technology. In this study, a new portable XRF analyzer based on the use of doubly curved crystal optics (HD Mobile®) was evaluated for detecting toxic elements in foods, medicines, cosmetics and spices used in many Asian communities. Two models of the HD Mobile® (a pre-production and a final production unit) were investigated. Performance parameters including accuracy, precision and detection limits were characterized in a laboratory setting using certified reference materials (CRMs) and standard solutions. Bias estimates for key elements of public health significance such as As, Cd, Hg and Pb ranged from - 10% to 11% for the pre-production, and - 14% to 16% for the final production model. Five archived public health samples including herbal medicine products, ethnic spices and cosmetic products were analyzed using both XRF instruments. There was good agreement between the pre-production and final production models for the four key elements, such that the data were judged to be fit-for-purpose for the majority of samples analyzed. Detection of the four key elements of interest using the HD Mobile® was confirmed using archived samples for which ICP-OES data were available based on digested sample materials. The HD Mobile® XRF units were shown to be suitable for rapid screening of samples likely to be encountered in field based studies.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shattan, Michael; Stowe, Ashley; McIntosh, Kathryn
Explore feasibility of portable LIBS and micro-XRF systems as methods of field screening for real debris; Develop a LIBS Capability to rapidly screen beads for production quality control; Complete 3D elemental mapping of surrogate debris to determine uranium and other elemental migration patterns during debris formation
Reflections on the challenges and possibilities of journal publication in science education
NASA Astrophysics Data System (ADS)
Milne, Catherine; Siry, Christina; Mueller, Michael
2015-12-01
In this editorial we reflect on the intersections between the review and publishing policies of Cultural Studies of Science Education (CSSE) and the challenges and possibilities in global science education publishing. In particular we discuss the tensions associated with open or closed review policies, the hegemony of English as a language of publication, and reflect on some of the common challenges experienced by editors and authors from different contexts. We draw on the paper set in this issue consisting of five papers focused on publishing in various contexts, and elaborate several central questions for the field of science education and the dissemination of knowledges.
UNCERTAINTY IN SCALING NUTRIENT EXPORT COEFFICIENTS
The Innov-X XT400 portable XRF analyzer features a miniature, rugged x-ray tube excitation source for analyzing a wide variety of elements and sample materials, including alloys, environmental solids, and other analytical samples. The x-ray tube source and Light Element Analysis...
SEP-Kr and SEP-Xe in Lunar Ilmenite and the Ar/Kr/Xe Ratio in the Solar Wind
NASA Astrophysics Data System (ADS)
Wieler, R.; Baur, H.; Signer, P.
1992-07-01
We analyzed all five noble gases in an ilmenite sample from lunar soil 71501 by closed system stepped etching (CSSE), thus extending our CSSE studies of solar noble gases (Wieler et al., 1986; Benkert et al., 1988) to Kr and Xe. He, Ne, Ar isotopes: We observe the familiar presence of two solar noble gas components: step 1 shows ^4He/^3He = 2250, ^20Ne/^22Ne = 13.8, and ^36Ar/^38Ar=5.46. The first two ratios are essentially identical to modern solar wind values (SWC; Geiss, 1973), indicating an isotopically unfractionated SW noble gas reservoir in lunar ilmenite. The Ne data-points of later steps fall on a straight line and reach the SEP-Ne point (^20Ne/^22Ne = 11.3). The slope of this line indicates mass dependent fractionation between SW-Ne and SEP-Ne. SEP-He (^4He/^3He = 4650 +-100) and SEP-Ar (^36Ar/^38Ar = 4.89+-0.05) are also observed (latter two numbers slightly revised compared to Wieler et al., 1992). Kr, Xe isotopes: Kr in those two steps that release pure SW-Ne is very slightly lighter than atmospheric Kr (^86Kr/^84Kr = 0.3041; see also Wieler et al., 1992). We interpret this to be SW-Kr in soil 71501. Steps containing (isotopically heavier) SEP-Ne likewise release heavier Kr, interpreted accordingly as SEP-Kr (^86Kr/^84Kr = 0.323). Similarly, a light Xe component is released first (SW-Xe, ^136Xe/^132Xe = 0.3003), followed by heavier SEP-Xe (^136Xe/^132Xe = 0.319). The data are consistent with both Kr and Xe in SW and SEP components to be related by mass fractionation. The relation first proposed by Benkert et al. (1988) between a ratio R(m(sub)2,m(sub)1) of two isotopes with masses m(sub)2>m(sub)1 in SW and SEP now holds for all five noble gases: (R(sub)SW-R(sub)SEP)/R(sub)SW = (2+-0.13)*(m(sub)2- m(sub)1)/m(sub)2. Since m(sub)2~m(sub)1, this relation may also be written as: R(sub)SEP/R(sub)SW ~ (m(sub)1/m(sub)2)^2 (Geiss and Bochsler, 1991). Element ratios: ^4He/^36Ar and ^20Ne/^36Ar rise from values several times below SWC to essentially SWC ratios in the steps releasing nearly pure SEP gases, indicating element fractionation between SW-He/Ne, but essentially unfractionated SEP-He/Ne/Ar in lunar ilmenite. In contrast, Kr/Xe stays virtually constant (^84Kr/^132Xe = 8.4+-0.5), except in the first few steps. If the light three noble gases indeed are not fractionated in the SEP dominated steps, we would also expect no fractionation for Kr/Xe. The measured ^84Kr/^132Xe ratio is, however, about 2.4 times lower than the most recent "solar system" ratio (Anders and Grevesse, 1989), albeit only ~30% lower than the "solar" value preferred by Marti and Suess (1988). Kr/Xe ratios similar to those in ilmenites have been found earlier, e.g. in Peysanoe (Marti, 1969). They are often taken to indicate fractionated loss of solar noble gases. Based on the new CSSE results, we propose, instead, that lunar ilmenites retain a faithful record of ^84Kr/^132Xe in SW and SEP (and also ^36Ar/^84Kr(sub)SW = 1750+- 300). If so, this may indicate noble gas fractionation in the solar corpuscular radiation, perhaps depending on first ionization potential or a related parameter. Work supported by the Swiss National Science Foundation. References: Anders, E. and Grevesse, N. (1989) Geochim. Cosmochim. Acta. 53, 197-214. Benkert, J.-P. et al. (1988) Lunar Planet. Sci. (abstract) 19, 59-60. Geiss, J. (1973) Proc. 13th Int. Cosmic Ray Conf. 3375-3398. Geiss, J. and Bochsler, P. (1991) In The Sun in Time (eds. C. P. Sonett, M. S. Giampapa and M.S. Matthews), pp. 98-117. Univ. Arizona Press, Tucson, Arizona. Marti, K. (1969) Science. 166. 1263-1265. Marti, K. and Suess, H. E. (1988) Astrophys. Space Sci. 144. 507-517. Wieler, R. et al. (1986) Geochim. Cosmochim. Acta. 50. 1997-2017. Wieler, R. et al. (1992) Lunar Planet. Sci. (abstract) 23.
PELAN: a pulsed neutron portable probe for UXO and land mine identification
NASA Astrophysics Data System (ADS)
Vourvopoulos, George; Womble, Phillip C.; Paschal, Jonathon
2000-12-01
There has been much work increasing the sensitivity of detecting metallic objects in soils and other environments. This has lead to a problem in discriminating unexploded ordnance (UXO) and landmines form other metallic clutter. PELAN is a small portable system for the detection of explosives. PELAN weights less than 45 kg and is man portable. It is based on the principle that explosives and other contraband contain various chemical elements such as H, C, N, O, etc. in quantities and ratios that differentiate them from other innocuous substances. The pulsed neutrons are produced with a 14 MeV neutron generator. Separate gamma-ray spectra form fast neutron, thermal neutron and activation reactions are accumulated and analyzed to determine elemental content. The data analysis is performed in an automatic manner and a result of whether a threat is present is returned to the operator. PELAN has successfully undergone field demonstrations for explosive detection. In this paper, we will discuss the application of PELAN to the problem of differentiating threats from metallic clutter.
Water analysis via portable X-ray fluorescence spectrometry
NASA Astrophysics Data System (ADS)
Pearson, Delaina; Chakraborty, Somsubhra; Duda, Bogdan; Li, Bin; Weindorf, David C.; Deb, Shovik; Brevik, Eric; Ray, D. P.
2017-01-01
Rapid, in-situ elemental water analysis would be an invaluable tool in studying polluted and/or salt-impacted waters. Analysis of water salinity has commonly used electrical conductance (EC); however, the identity of the elements responsible for the salinity are not revealed using EC. Several studies have established the viability of using portable X-ray fluorescence (PXRF) spectrometry for elemental data analysis of soil, sediment, and other matrices. However, the accuracy of PXRF is known to be affected while scanning moisture-laden soil samples. This study used PXRF elemental data in water samples to predict water EC. A total of 256 water samples, from 10 different countries were collected and analyzed via PXRF, inductively coupled plasma atomic emission spectroscopy (ICP-AES), and a digital salinity bridge. The PXRF detected some elements more effectively than others, but overall results indicated that PXRF can successfully predict water EC via quantifying Cl in water samples (validation R2 and RMSE of 0.77 and 0.95 log μS cm-1, respectively). The findings of this study elucidated the potential of PXRF for future analysis of pollutant and/or metal contaminated waters.
NASA Astrophysics Data System (ADS)
Zeng, Lvming; Liu, Guodong; Yang, Diwu; Ren, Zhong; Huang, Zhen
2008-12-01
A near-infrared photoacoustic glucose monitoring system, which is integrated dual-wavelength pulsed laser diode excitation with eight-element planar annular array detection technique, is designed and fabricated during this study. It has the characteristics of nonivasive, inexpensive, portable, accurate location, and high signal-to-noise ratio. In the system, the exciting source is based on two laser diodes with wavelengths of 905 nm and 1550 nm, respectively, with optical pulse energy of 20 μJ and 6 μJ. The laser beam is optically focused and jointly projected to a confocal point with a diameter of 0.7 mm approximately. A 7.5 MHz 8-element annular array transducer with a hollow structure is machined to capture photoacoustic signal in backward mode. The captured signals excitated from blood glucose are processed with a synthetic focusing algorithm to obtain high signal-to-noise ratio and accurate location over a range of axial detection depth. The custom-made transducer with equal area elements is coaxially collimated with the laser source to improve the photoacoustic excite/receive efficiency. In the paper, we introduce the photoacoustic theory, receive/process technique, and design method of the portable noninvasive photoacoustic glucose monitoring system, which can potentially be developed as a powerful diagnosis and treatment tool for diabetes mellitus.
A demonstration of field portable/mobile technologies for measuring trace elements in soil and sediments was conducted under the U.S. Environmental Protection Agency Superfund Innovative Technology Evaluation (SITE) Program. The demonstration took place from January 24 to 28, 200...
Durable Suit Bladder with Improved Water Permeability for Pressure and Environment Suits
NASA Technical Reports Server (NTRS)
Bue, Grant C.; Kuznetz, Larry; Orndoff, Evelyne; Tang, Henry; Aitchison, Lindsay; Ross, Amy
2009-01-01
Water vapor permeability is shown to be useful in rejecting heat and managing moisture accumulation in launch-and-entry pressure suits. Currently this is accomplished through a porous Gortex layer in the Advanced Crew and Escape Suit (ACES) and in the baseline design of the Constellation Suit System Element (CSSE) Suit 1. Non-porous dense monolithic membranes (DMM) that are available offer potential improvements for water vapor permeability with reduced gas leak. Accordingly, three different pressure bladder materials were investigated for water vapor permeability and oxygen leak: ElasthaneTM 80A (thermoplastic polyether urethane) provided from stock polymer material and two custom thermoplastic polyether urethanes. Water vapor, carbon dioxide and oxygen permeability of the DMM's was measured in a 0.13 mm thick stand-alone layer, a 0.08 mm and 0.05 mm thick layer each bonded to two different nylon and polyester woven reinforcing materials. Additional water vapor permeability and mechanical compression measurements were made with the reinforced 0.05 mm thick layers, further bonded with a polyester wicking and overlaid with moistened polyester fleece thermal underwear .This simulated the pressure from a supine crew person. The 0.05 mm thick nylon reinforced sample with polyester wicking layer was further mechanically tested for wear and abrasion. Concepts for incorporating these materials in launch/entry and Extravehicular Activity pressure suits are presented.
NASA Astrophysics Data System (ADS)
Zhang, X.; Karanassios, V.
2012-06-01
A solar-powered, battery-operated, atmospheric-pressure, self-igniting microplasma the size of a sugar-cube developed on a hybrid, 3d-chip is described. Rapid prototyping of the 3d-chip; some fundamental aspects and a brief characterization of its background spectral emission using a portable, fiber-optic spectrometer are discussed.
Code of Federal Regulations, 2012 CFR
2012-10-01
... external heat. Fusible elements must not be utilized on portable tanks with a test pressure which exceeds 2... conductance of the insulation, in kW m −2 K −1, at 38 °C (100 °F); and t = actual temperature of the hazardous... given in this paragraph (i)(2)(i)(A) for insulated shells may only be used if the insulation is in...
Code of Federal Regulations, 2014 CFR
2014-10-01
... external heat. Fusible elements must not be utilized on portable tanks with a test pressure which exceeds 2... conductance of the insulation, in kW m −2 K −1, at 38 °C (100 °F); and t = actual temperature of the hazardous... given in this paragraph (i)(2)(i)(A) for insulated shells may only be used if the insulation is in...
Code of Federal Regulations, 2013 CFR
2013-10-01
... external heat. Fusible elements must not be utilized on portable tanks with a test pressure which exceeds 2... conductance of the insulation, in kW m −2 K −1, at 38 °C (100 °F); and t = actual temperature of the hazardous... given in this paragraph (i)(2)(i)(A) for insulated shells may only be used if the insulation is in...
Code of Federal Regulations, 2011 CFR
2011-10-01
... external heat. Fusible elements must not be utilized on portable tanks with a test pressure which exceeds 2... conductance of the insulation, in kW m −2 K −1, at 38 °C (100 °F); and t = actual temperature of the hazardous... given in this paragraph (i)(2)(i)(A) for insulated shells may only be used if the insulation is in...
Code of Federal Regulations, 2010 CFR
2010-10-01
... external heat. Fusible elements must not be utilized on portable tanks with a test pressure which exceeds 2... conductance of the insulation, in kW m −2 K −1, at 38 °C (100 °F); and t = actual temperature of the hazardous... given in this paragraph (i)(2)(i)(A) for insulated shells may only be used if the insulation is in...
Proposal for a prototype of portable μXRF spectrometer
NASA Astrophysics Data System (ADS)
Polese, C.; Dabagov, S. B.; Esposito, A.; Liedl, A.; Hampai, D.; Bartùli, C.; Ferretti, M.
2015-07-01
μXRF is a powerful instrument for non-destructive characterization of materials of cultural interest. At the XLab Frascati Laboratory this technique is already well performed thanks to the polyCO set equipment allowing simultaneous μXRF 2D mapping. However, due to the strict demand for in situ analysis in this particular field, a new portable μXRF spectrometer equipped with a full polycapillary lens conjugated with a transmission anode X-ray tube is proposed. Many cultural objects are characterized by elements (Ag, Sn, etc.) with high energy fluorescence K-lines. Thus, the capability of a full lens to deliver a high energy fraction of X-ray spectrum, in order to excite the fluorescence K-lines of such elements, is tested.
Lin, Bingqian; Liu, Dan; Yan, Jinmao; Qiao, Zhi; Zhong, Yunxin; Yan, Jiawei; Zhu, Zhi; Ji, Tianhai; Yang, Chaoyong James
2016-03-23
There is considerable demand for sensitive, selective, and portable detection of disease-associated proteins, particularly in clinical practice and diagnostic applications. Portable devices are highly desired for detection of disease biomarkers in daily life due to the advantages of being simple, rapid, user-friendly, and low-cost. Herein we report an enzyme-encapsulated liposome-linked immunosorbent assay for sensitive detection of proteins using personal glucose meters (PGM) for portable quantitative readout. Liposomes encapsulating a large amount of amyloglucosidase or invertase are surface-coated with recognition elements such as aptamers or antibodies for target recognition. By translating molecular recognition signal into a large amount of glucose with the encapsulated enzyme, disease biomarkers such as thrombin or C-reactive protein (CRP) can be quantitatively detected by a PGM with a high detection limit of 1.8 or 0.30 nM, respectively. With the advantages of portability, ease of use, and low-cost, the method reported here has potential for portable and quantitative detection of various targets for different POC testing scenarios, such as rapid diagnosis in clinic offices, health monitoring at the bedside, and chemical/biochemical safety control in the field.
Code of Federal Regulations, 2010 CFR
2010-10-01
... exchange carrier's switching ports as unbundled network elements under section 251 of the Communications Act, and/or Feature Group A access lines, and resellers of the incumbent local exchange carrier's... network elements under section 251. (iv) The incumbent local exchange carrier shall levelize the monthly...
Portable telepathology: methods and tools.
Alfaro, Luis; Roca, Ma José
2008-07-15
Telepathology is becoming easier to implement in most pathology departments. In fact e-mail image transmit can be done from almost any pathologist as a simplistic telepathology system. We tried to develop a way to improve capabilities of communication among pathologists with the idea that the system should be affordable for everybody. We took the premise that any pathology department would have microscopes and computers with Internet connection, and selected a few elements to convert them into a telepathology station. Needs were reduced to a camera to collect images, a universal microscope adapter for the camera, a device to connect the camera to the computer, and a software for the remote image transmit. We found out a microscope adapter (MaxView Plus) that allowed us connect almost any domestic digital camera to any microscope. The video out signal from the camera was sent to the computer through an Aver Media USB connector. At last, we selected a group of portable applications that were assembled into a USB memory device. Portable applications are computer programs that can be carried generally on USB flash drives, but also in any other portable device, and used on any (Windows) computer without installation. Besides, when unplugging the device, none of personal data is left behind. We selected open-source applications, and based the pathology image transmission to VLC Media Player due to its functionality as streaming server, portability and ease of use and configuration. Audio transmission was usually done through normal phone lines. We also employed alternative videoconferencing software, SightSpeed for bi-directional image transmission from microscopes, and conventional cameras allowing visual communication and also image transmit from gross pathology specimens. All these elements allowed us to install and use a telepathology system in a few minutes, fully prepared for real time image broadcast.
Portable telepathology: methods and tools
Alfaro, Luis; Roca, Ma José
2008-01-01
Telepathology is becoming easier to implement in most pathology departments. In fact e-mail image transmit can be done from almost any pathologist as a simplistic telepathology system. We tried to develop a way to improve capabilities of communication among pathologists with the idea that the system should be affordable for everybody. We took the premise that any pathology department would have microscopes and computers with Internet connection, and selected a few elements to convert them into a telepathology station. Needs were reduced to a camera to collect images, a universal microscope adapter for the camera, a device to connect the camera to the computer, and a software for the remote image transmit. We found out a microscope adapter (MaxView Plus) that allowed us connect almost any domestic digital camera to any microscope. The video out signal from the camera was sent to the computer through an Aver Media USB connector. At last, we selected a group of portable applications that were assembled into a USB memory device. Portable applications are computer programs that can be carried generally on USB flash drives, but also in any other portable device, and used on any (Windows) computer without installation. Besides when unplugging the device, none of personal data is left behind. We selected open-source applications, and based the pathology image transmission to VLC Media Player due to its functionality as streaming server, portability and ease of use and configuration. Audio transmission was usually done through normal phone lines. We also employed alternative videoconferencing software, SightSpeed for bi-directional image transmission from microscopes, and conventional cameras allowing visual communication and also image transmit from gross pathology specimens. All these elements allowed us to install and use a telepathology system in a few minutes, fully prepared for real time image broadcast. PMID:18673507
Exploring microdischarges for portable sensing applications.
Gianchandani, Y B; Wright, S A; Eun, C K; Wilson, C G; Mitra, B
2009-10-01
This paper describes the use of microdischarges as transducing elements in sensors and detectors. Chemical and physical sensing of gases, chemical sensing of liquids, and radiation detection are described. These applications are explored from the perspective of their use in portable microsystems, with emphasis on compactness, power consumption, the ability to operate at or near atmospheric pressure (to reduce pumping challenges), and the ability to operate in an air ambient (to reduce the need for reservoirs of carrier gases). Manufacturing methods and performance results are described for selected examples.
1991-07-01
synchronous machine case study . IEEE T rons. on For the ease nd -nq -2, four time scales trust be used And the A.C, Vol. 36. nul 3, March 1989. damnper... studied . A spot welded(Csse 3) * ss s i* r 0. or a line welded( Case 4) reinforcement plate is attached on the colliding surface of box beams arnd their...phased armature, is given on Figure 1. analytical field calculation in the machine magnetic structure. Il - MAGNETIC STRUCTURE MODELLING: In the case
Normative values for a tablet computer-based application to assess chromatic contrast sensitivity.
Bodduluri, Lakshmi; Boon, Mei Ying; Ryan, Malcolm; Dain, Stephen J
2018-04-01
Tablet computer displays are amenable for the development of vision tests in a portable form. Assessing color vision using an easily accessible and portable test may help in the self-monitoring of vision-related changes in ocular/systemic conditions and assist in the early detection of disease processes. Tablet computer-based games were developed with different levels of gamification as a more portable option to assess chromatic contrast sensitivity. Game 1 was designed as a clinical version with no gaming elements. Game 2 was a gamified version of game 1 (added fun elements: feedback, scores, and sounds) and game 3 was a complete game with vision task nested within. The current study aimed to determine the normative values and evaluate repeatability of the tablet computer-based games in comparison with an established test, the Cambridge Colour Test (CCT) Trivector test. Normally sighted individuals [N = 100, median (range) age 19.0 years (18-56 years)] had their chromatic contrast sensitivity evaluated binocularly using the three games and the CCT. Games 1 and 2 and the CCT showed similar absolute thresholds and tolerance intervals, and game 3 had significantly lower values than games 1, 2, and the CCT, due to visual task differences. With the exception of game 3 for blue-yellow, the CCT and tablet computer-based games showed similar repeatability with comparable 95% limits of agreement. The custom-designed games are portable, rapid, and may find application in routine clinical practice, especially for testing younger populations.
Villaverde Bonilla, Valentín; Ródenas Marín, Isabel; Murcia Mascarós, Sonia
2016-01-01
In this work we analyze the pigments used in the decoration of red and yellow motifs present in the portable art of the Parpalló Cave (Gandía, Spain), one of the most important Palaeolithic sites in the Spanish Mediterranean region. Energy dispersive X-ray fluorescence spectrometry (EDXRF) and spectrophotometry in the visible region (CIEL*a*b*color coordinates and spectral reflectance curves) were used to perform in situ fast analyses of the red and yellow motifs with portable equipment and to characterize their elemental composition and their colorimetric perception, respectively. According to the elemental composition, the intensity of the fluorescence iron signals in red and yellow motifs are higher than average values in the rock substrates. As expected, red motifs possess high values of the chromatic coordinate a* and yellow motifs possess high values of b*. This characterization was complemented with FT-IR analyses of microsamples detached from the red and yellow colored zones of a small set of plaquettes. Our results show that the artists used red and yellow pigments in the decoration likely derived from natural iron oxides as hematite and goethite. PMID:27732605
Roldán García, Clodoaldo; Villaverde Bonilla, Valentín; Ródenas Marín, Isabel; Murcia Mascarós, Sonia
2016-01-01
In this work we analyze the pigments used in the decoration of red and yellow motifs present in the portable art of the Parpalló Cave (Gandía, Spain), one of the most important Palaeolithic sites in the Spanish Mediterranean region. Energy dispersive X-ray fluorescence spectrometry (EDXRF) and spectrophotometry in the visible region (CIEL*a*b*color coordinates and spectral reflectance curves) were used to perform in situ fast analyses of the red and yellow motifs with portable equipment and to characterize their elemental composition and their colorimetric perception, respectively. According to the elemental composition, the intensity of the fluorescence iron signals in red and yellow motifs are higher than average values in the rock substrates. As expected, red motifs possess high values of the chromatic coordinate a* and yellow motifs possess high values of b*. This characterization was complemented with FT-IR analyses of microsamples detached from the red and yellow colored zones of a small set of plaquettes. Our results show that the artists used red and yellow pigments in the decoration likely derived from natural iron oxides as hematite and goethite.
1999-01-01
the previous sortie. 47 Portable Maintenance Data Store (PMDS). The PMDS is a solid state memory device approximately the same size as an...Engine Titanium Consortium Portable Scanner Bridging the gap between rapid imaging and robots is a class of inspection devices called scanners...patterns on the image to change . Thus, a region approximately the size of the sensor element (3 inches in diameter) can be inspected at one time, and an
McComb, Jacqueline Q.; Rogers, Christian; Han, Fengxiang X.; Tchounwou, Paul B.
2014-01-01
With industrialization, great amounts of trace elements and heavy metals have been excavated and released on the surface of the earth and dissipated into the environments. Rapid screening technology for detecting major and trace elements as well as heavy metals in variety of environmental samples is most desired. The objectives of this study were to determine the detection limits, accuracy, repeatability and efficiency of a X-ray fluorescence spectrometer (Niton XRF analyzer) in comparison with the traditional analytical methods, inductively coupled plasma optical emission spectrometer (ICP-OES) and inductively coupled plasma optical emission spectrometer (ICP-MS) in screening of major and trace elements of environmental samples including estuary soils and sediments, contaminated soils, and biological samples. XRF is a fast and non-destructive method in measuring the total concentration of multi--elements simultaneously. Contrary to ICP-OES and ICP-MS, XRF analyzer is characterized by the limited preparation required for solid samples, non-destructive analysis, increased total speed and high throughout, the decreased production of hazardous waste and the low running costs as well as multi-elemental determination and portability in the fields. The current comparative study demonstrates that XRF is a good rapid non-destructive method for contaminated soils, sediments and biological samples containing higher concentrations of major and trace elements. Unfortunately, XRF does not have sensitive detection limits of most major and trace elements as ICP-OES or ICP-MS but it may serve as a rapid screening tool for locating hot spots of uncontaminated field soils and sediments. PMID:25861136
Recent trends in atomic fluorescence spectrometry towards miniaturized instrumentation-A review.
Zou, Zhirong; Deng, Yujia; Hu, Jing; Jiang, Xiaoming; Hou, Xiandeng
2018-08-17
Atomic fluorescence spectrometry (AFS), as one of the common atomic spectrometric techniques with high sensitivity, simple instrumentation, and low acquisition and running cost, has been widely used in various fields for trace elemental analysis, notably the determination of hydride-forming elements by hydride generation atomic fluorescence spectrometry (HG-AFS). In recent years, the soaring demand of field analysis has significantly promoted the miniaturization of analytical atomic spectrometers or at least instrumental components. Various techniques have also been developed to approach the goal of portable/miniaturized AFS instrumentation for field analysis. In this review, potentially portable/miniaturized AFS techniques, primarily involving advanced instrumental components and whole instrumentation with references since 2000, are summarized and discussed. The discussion mainly includes five aspects: radiation source, atomizer, detector, sample introduction, and miniaturized atomic fluorescence spectrometer/system. Copyright © 2018 Elsevier B.V. All rights reserved.
Radioactive sample effects on EDXRF spectra
DOE Office of Scientific and Technical Information (OSTI.GOV)
Worley, Christopher G
2008-01-01
Energy dispersive X-ray fluorescence (EDXRF) is a rapid, straightforward method to determine sample elemental composition. A spectrum can be collected in a few minutes or less, and elemental content can be determined easily if there is adequate energy resolution. Radioactive alpha emitters, however, emit X-rays during the alpha decay process that complicate spectral interpretation. This is particularly noticeable when using a portable instrument where the detector is located in close proximity to the instrument analysis window held against the sample. A portable EDXRF instrument was used to collect spectra from specimens containing plutonium-239 (a moderate alpha emitter) and americium-241 (amore » heavy alpha emitter). These specimens were then analyzed with a wavelength dispersive XRF (WDXRF) instrument to demonstrate the differences to which sample radiation-induced X-ray emission affects the detectors on these two types of XRF instruments.« less
Crime scene investigations using portable, non-destructive space exploration technology
NASA Technical Reports Server (NTRS)
Trombka, Jacob I.; Schweitzer, Jeffrey; Selavka, Carl; Dale, Mark; Gahn, Norman; Floyd, Samuel; Marie, James; Hobson, Maritza; Zeosky, Jerry; Martin, Ken;
2002-01-01
The National Institute of Justice (NIJ) and the National Aeronautics and Space Administration's (NASAs) Goddard Space Flight Center (GSFC) have teamed up to explore the use of NASA developed technologies to help criminal justice agencies and professionals solve crimes. The objective of the program is to produce instruments and communication networks that have application within both NASA's space program and NIJ programs with state and local forensic laboratories. A working group of NASA scientists and law enforcement professionals has been established to develop and implement a feasibility demonstration program. Specifically, the group has focused its efforts on identifying gunpowder and primer residue, blood, and semen at crime scenes. Non-destructive elemental composition identification methods are carried out using portable X-ray fluorescence (XRF) systems. These systems are similar to those being developed for planetary exploration programs. A breadboard model of a portable XRF system has been constructed for these tests using room temperature silicon and cadmium-zinc telluride (CZT) detectors. Preliminary tests have been completed with gunshot residue (GSR), blood-spatter and semen samples. Many of the element composition lines have been identified. Studies to determine the minimum detectable limits needed for the analyses of GSR, blood and semen in the crime scene environment have been initiated and preliminary results obtained. Furthermore, a database made up of the inorganic composition of GSR is being developed. Using data obtained from the open literature of the elemental composition of barium (Ba) and antimony (Sb) in handswipes of GSR, we believe that there may be a unique GSR signature based on the Sb to Ba ratio.
A review of the development of portable laser induced breakdown spectroscopy and its applications
NASA Astrophysics Data System (ADS)
Rakovský, J.; Čermák, P.; Musset, O.; Veis, P.
2014-11-01
In this review, we present person-transportable laser induced breakdown spectroscopy (LIBS) devices that have previously been developed and reported in the literature as well as their applications. They are compared with X-ray fluorescent (XRF) devices, which represent their strongest competition. Although LIBS devices have advantages over XRF devices, such as sensitivity to the light elements, high spatial resolution and the possibility to distinguish between different layers of the sample, there are also disadvantages and both are discussed here. Furthermore, the essential portable LIBS instrumentation (laser, spectrograph and detector) is presented, and published results related to new laser sources (diode-pumped solid-state, microchip and fiber lasers) used in LIBS are overviewed. Compared to conventional compact flashlamp pumped solid-state lasers, the new laser sources provide higher repetition rates, higher efficiency (less power consumption) and higher beam quality, resulting in higher fluences, even for lower energies, and could potentially increase the figure of merit of portable LIBS instruments. Compact spectrometers used in portable LIBS devices and their parts (spectrograph, detector) are also discussed.
Simulation Fidelity Issues for Nuclear Survivability Validation Protocols.
1992-11-01
Explosive MILSTAR Military, Strategic and Tactical Relay satellite NTB National Test Bed PORTS Portable Radiation/Redout Testbed for Sensors RV Reentry...Vehicle SDI Strategic Defense Initiative SE System Element SEP System Element Platform SGEMP System Generated Electromagnetic Pulse S/N Signal-to...ELECTRONIC SCIENCES DIV ATTN: ACTL ATTN: CHIEF SCIENTIST ATTN: DDIR ATTN: DEP DIR RESEARCH ATTN: DFOP ATTN: DIR AEROSPACE & STRATEGIC TECH Dist-1 DNA-TR-92
Preliminary testing of a prototype portable X-ray fluorescence spectrometer
NASA Technical Reports Server (NTRS)
Patten, L. L.; Anderson, N. B.; Stevenson, J. J.
1982-01-01
A portable X-ray fluorescence spectrometer for use as an analyzer in mineral resource investigative work was built and tested. The prototype battery powered spectrometer, measuring 11 by 12 by 5 inches and weighing only about 15 pounds, was designed specifically for field use. The spectrometer has two gas proportional counters and two radioactive sources, Cd (10a) and Fe (55). Preliminary field and laboratory tests on rock specimens and rock pulps have demonstrated the capability of the spectrometer to detect 33 elements to date. Characteristics of the system present some limitations, however, and further improvements are recommended.
A 32 x 32 capacitive micromachined ultrasonic transducer array manufactured in standard CMOS.
Lemmerhirt, David F; Cheng, Xiaoyang; White, Robert; Rich, Collin A; Zhang, Man; Fowlkes, J Brian; Kripfgans, Oliver D
2012-07-01
As ultrasound imagers become increasingly portable and lower cost, breakthroughs in transducer technology will be needed to provide high-resolution, real-time 3-D imaging while maintaining the affordability needed for portable systems. This paper presents a 32 x 32 ultrasound array prototype, manufactured using a CMUT-in-CMOS approach whereby ultrasonic transducer elements and readout circuits are integrated on a single chip using a standard integrated circuit manufacturing process in a commercial CMOS foundry. Only blanket wet-etch and sealing steps are added to complete the MEMS devices after the CMOS process. This process typically yields better than 99% working elements per array, with less than ±1.5 dB variation in receive sensitivity among the 1024 individually addressable elements. The CMUT pulseecho frequency response is typically centered at 2.1 MHz with a -6 dB fractional bandwidth of 60%, and elements are arranged on a 250 μm hexagonal grid (less than half-wavelength pitch). Multiplexers and CMOS buffers within the array are used to make on-chip routing manageable, reduce the number of physical output leads, and drive the transducer cable. The array has been interfaced to a commercial imager as well as a set of custom transmit and receive electronics, and volumetric images of nylon fishing line targets have been produced.
Marchese, N; Cannuli, A; Caccamo, M T; Pace, C
2017-01-01
Neutron sources are increasingly employed in a wide range of research fields. For some specific purposes an alternative to existing large-scale neutron scattering facilities, can be offered by the new generation of portable neutron devices. This review reports an overview for such recently available neutron generators mainly addressed to biophysics applications with specific reference to portable non-stationary neutron generators applied in Neutron Activation Analysis (NAA). The review reports a description of a typical portable neutron generator set-up addressed to biophysics applications. New generation portable neutron devices, for some specific applications, can constitute an alternative to existing large-scale neutron scattering facilities. Deuterium-Deuterium pulsed neutron sources able to generate 2.5MeV neutrons, with a neutron yield of 1.0×10 6 n/s, a pulse rate of 250Hz to 20kHz and a duty factor varying from 5% to 100%, when combined with solid-state photon detectors, show that this kind of compact devices allow rapid and user-friendly elemental analysis. "This article is part of a Special Issue entitled "Science for Life" Guest Editor: Dr. Austen Angell, Dr. Salvatore Magazù and Dr. Federica Migliardo". Copyright © 2016 Elsevier B.V. All rights reserved.
Analysis of metal-laden water via portable X-ray fluorescence spectrometry
NASA Astrophysics Data System (ADS)
Pearson, Delaina; Weindorf, David C.; Chakraborty, Somsubhra; Li, Bin; Koch, Jaco; Van Deventer, Piet; de Wet, Jandre; Kusi, Nana Yaw
2018-06-01
A rapid method for in-situ elemental composition analysis of metal-laden water would be indispensable for studying polluted water. Current analytical lab methods to determine water quality include flame atomic absorption spectrometry (FAAS), atomic absorption spectrophotometry (AAS), electrothermal atomic absorption spectrometry (EAAS), and inductively coupled plasma (ICP) spectroscopy. However only two field methods, colorimetry and absorptiometry, exist for elemental analysis of water. Portable X-ray fluorescence (PXRF) spectrometry is an effective method for elemental analysis of soil, sediment, and other matrices. However, the accuracy of PXRF is known to be affected while scanning moisture-laden soil samples. This study sought to statistically establish PXRF's predictive ability for various elements in water at different concentrations relative to inductively coupled plasma atomic emission spectroscopy (ICP-AES). A total of 390 metal-laden water samples collected from leaching columns of mine tailings in South Africa were analyzed via PXRF and ICP-AES. The PXRF showed differential effectiveness in elemental quantification. For the collected water samples, the best relationships between ICP and PXRF elemental data were obtained for K and Cu (R2 = 0.92). However, when scanning ICP calibration solutions with elements in isolation, PXRF results indicated near perfect agreement; Ca, K, Fe, Cu and Pb produced an R2 of 0.99 while Zn and Mn produced an R2 of 1.00. The utilization of multiple PXRF (stacked) beams produced stronger correlation to ICP relative to the use of a single beam in isolation. The results of this study demonstrated the PXRF's ability to satisfactorily predict the composition of metal-laden water as reported by ICP for several elements. Additionally this study indicated the need for a "Water Mode" calibration for the PXRF and demonstrates the potential of PXRF for future study of polluted or contaminated waters.
Appel, Michael Y; Nachshon, Liat; Elizur, Arnon; Levy, Michael B; Katz, Yitzhak; Goldberg, Michael R
2018-05-14
The prevalence of sesame food allergy (SFA) has increased over recent years, with the potential of anaphylactic reactions upon exposure. Oral food challenge (OFC) remains the diagnostic standard, yet its implementation may be risky. Commercial skin prick tests (SPT) have a low sensitivity. Investigation of alternate diagnostic methods is warranted. To evaluate the utility of SPT and the basophil activation test (BAT) for SFA diagnosis. Eighty-two patients with suspected SFA completed an open OFC to sesame or reported a recent confirmed reaction. Patients were administered skin prick tests (SPT) with commercial sesame seed extract (CSSE), and a high protein concentration sesame extract (HPSE) (100 mg/ml protein). Whole blood from eighty patients was stimulated with sesame seed extract (40-10000 ng/ml protein) for BAT), assessing CD63 and CD203c as activation markers. Sixty patients (73%) had IgE-mediated reactions to sesame, and 22 (27%) did not react. Receiver operating characteristic (ROC) curve analysis demonstrated an area under the curve (AUC) of 0.87 for HPSE-SPT, and 0.66 for CSSE-SPT. At 1000 ng/ml of sesame protein, induction of CD63 and CD203c was weakly but significantly associated with OFC eliciting dose by rank (Spearman's rho= -0.42 (P<0.01) and -0.35 (P<0.05) for CD63 and CD203c, respectively). By ROC analysis, the AUC for CD63 was 0.86, and was 0.81 for CD203c sesame-induced basophil expression. Using HPSE-SPT as a first test to definitively diagnose (n=24) or rule out (n=5) SFA and BAT as a second test to diagnose the remainder, results in the correct classification of 73/80 (91%) patients, leaving one false negative and four false positive patients. Two BAT non-responders remain unclassified by this algorithm. While prospective cohort validation is necessary, joint utilization of BAT and SPT with HPSE extract may obviate the need for OFC in most SFA patients. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Watts, Winthrop F.; Gladis, David D.; Schumacher, Matthew F.; Ragatz, Adam C.; Kittelson, David B.
2010-01-01
A low cost, battery-operated, portable, real-time aerosol analyzer is not available for monitoring diesel particulate matter (DPM) concentrations in underground mines. This study summarizes a field evaluation conducted at an underground limestone mine to evaluate the potential of the TSI AM 510 portable photometer (equipped with a Dorr-Oliver cyclone and 1.0-μm impactor) to qualitatively track time-weighted average mass and elemental, organic, and total carbon (TC) measurements associated with diesel emissions. The calibration factor corrected correlation coefficient (R2) between the underground TC and photometer measurements was 0.93. The main issues holding back the use of a photometer for real-time estimation of DPM in an underground mine are the removal of non-DPM-associated particulate matter from the aerosol stream using devices, such as a cyclone and/or impactor and calibration of the photometer to mine-specific aerosol. PMID:20410071
NASA Astrophysics Data System (ADS)
Udeigwe, T. K.; Young, J.; Kandakji, T.; Weindorf, D. C.; Mahmoud, M. A.; Stietiya, M. H.
2015-04-01
This study extends the application of the portable X-ray fluorescence (PXRF) spectrometry to the examination of elements in semi-arid urban landscapes of the Southern High Plains (SHP) of the United States, focusing on golf courses. The complex environmental challenges of this region and the unique management practices at golf course facilities could lead to differences in concentration and in the chemistry of elements between managed (irrigated) and non-managed (non-irrigated) portions of these facilities. Soil samples were collected at depths of 0-10, 10-20, and 20-30 cm from managed and non-managed areas of seven different facilities in the city of Lubbock, Texas, and analyzed for a suite of soil properties. Total elemental quantification was conducted using a PXRF spectrometer. Findings mostly indicated no significant differences in the concentration of examined elements between the managed and non-managed areas of the facilities. However, strong positive relationships (R = 0.82-0.91, p < 0.001) were observed among elements (e.g., Fe on the one hand and Cr, Mn, Ni, and As on the other; Cu and Zn; As and Cr) and between these elements and soil constituents or properties such as clay, calcium carbonate, organic matter, and pH. The strengths of these relationships were mostly higher in the non-managed areas, suggesting a possible alteration in the chemistry of these elements by anthropogenic influences in the managed areas. Principal component and correlation analyses within the managed areas suggested that As, Cr, Fe, Mn, and Ni could be of lithogenic origin, while Cu, Pb, and Zn could have anthropogenic influences. Only one possible, likely lithogenic, source of the elements was identified within the non-managed areas. As evidenced by the study, the PXRF spectrometer can be a valuable tool for elemental quantification and rapid investigation of elemental interaction and source apportionment in semi-arid climates.
NASA Astrophysics Data System (ADS)
Udeigwe, T. K.; Young, J.; Kandakji, T.; Weindorf, D. C.; Mahmoud, M. A.; Stietiya, M. H.
2015-01-01
This study extends the application of the portable x-ray fluorescence (PXRF) spectrometry to examination of elements in semi-arid urban landscapes of the Southern High Plains (SHP) of the United States (US), focusing on golf courses. The complex environmental challenges of this region and the unique management practices at golf course facilities could lead to differences in concentration and chemistry of elements between managed (irrigated) and non-managed (non-irrigated) portions of these facilities. Soil samples were collected at the depths of 0-10, 10-20, and 20-30 cm from managed and non-managed areas of seven different facilities in the city of Lubbock, Texas, and analyzed for a suite of soil properties. Total elemental quantification was conducted using PXRF. Findings mostly indicated no significant differences in concentration of examined elements between the managed and non-managed areas of the facilities. However, strong positive relationships (R2 = 0.82-0.91, p < 0.001) were observed among elements (e.g. Fe and each of Cr, Mn, Ni, and As; Cu and Zn; As and Cr) and between these elements and soil constituents or properties such as clay, calcium carbonate, organic matter, and pH. The strengths of these relationships were mostly higher in the non-managed areas, suggesting possible alteration in the chemistry of these elements by anthropogenic influences. Principal component analyses (PCA) and correlation analyses within the managed areas suggested that As, Cr, Fe, Mn, and Ni could be of lithogenic origin, while Cu, Pb, and Zn were attributed to anthropogenic influences. Only one possible source of element, likely lithogenic, was identified within non-managed areas. As evidenced from the study, the PXRF can be a valuable tool for elemental quantification, and rapid investigation of elemental interaction and source apportionment in semi-arid climates.
NASA Astrophysics Data System (ADS)
Hark, R. R.; Harmon, R. S.; Remus, J. J.; East, L. J.; Wise, M. A.; Tansi, B. M.; Shughrue, K. M.; Dunsin, K. S.; Liu, C.
2012-04-01
Laser-induced breakdown spectroscopy (LIBS) offers a means of rapidly distinguishing different places of origin for a mineral because the LIBS plasma emission spectrum provides the complete chemical composition (i.e. geochemical fingerprint) of a mineral in real-time. An application of this approach with potentially significant commercial and political importance is the spectral fingerprinting of the 'conflict minerals' columbite-tantalite ("coltan"). Following a successful pilot study of three columbite-tantalite suites from the United States and Canada, a more geographically diverse set of samples from 37 locations worldwide were analyzed using a commercial laboratory LIBS system and a subset of samples also analyzed using a prototype broadband field-portable system. The spectral range from 250-490 nm was chosen for the laboratory analysis to encompass many of the intense emission lines for the major elements (Ta, Nb, Fe, Mn) and the significant trace elements (e.g., W, Ti, Zr, Sn, U, Sb, Ca, Zn, Pb, Y, Mg, and Sc) known to commonly substitute in the columbite-tantalite solid solution series crystal structure and in the columbite group minerals. The field-portable instrument offered an increased spectral range (198-1005 nm), over which all elements have spectral emission lines, and higher resolution than the laboratory instrument. In both cases, the LIBS spectra were analyzed using advanced multivariate statistical signal processing techniques. Partial Least Squares Discriminant Analysis (PLSDA) resulted in a correct place-level geographic classification at success rates between 90 and 100%. The possible role of rare-earth elements (REE's) as a factor contributing to the high levels of sample discrimination was explored. Given the fact that it can be deployed as a man-portable analytical technology, these results lend additional evidence that LIBS has the potential to be utilized in the field as a real-time tool to discriminate between columbite-tantalite ores of different provenance.
78 FR 78939 - 36(b)(1) Arms Sales Notification
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-27
... Quantity or Quantities of Articles or Services under Consideration for Purchase: C-130J technical, engineering and software support; software updates and patches; familiarization training for Portable Flight... and contractor technical support services; and other related elements of logistics and program support...
NASA Astrophysics Data System (ADS)
Ergenç, Duygu; Freire, David; Fort, Rafael
2016-04-01
The chemical characterization of lime mortars used in Roman period has a great significance and plays a key role in the acquisition of knowledge with respect to construction technology, raw materials and, accordingly, in its conservation works. When it comes to cultural heritage studies, sampling is always complicated since the minimum damage is the primary concern. The use of non-destructive techniques and direct measurements with portable devices reduce the amount of samples and time consumed in analyses, consequently it could be stated that such techniques are extremely useful in conservation and restoration works. In this study, the portable XRF device was used to determine the composition of chemical elements which compose the Roman lime mortars in the archaeological site of Complutum, Alcalá de Henares (Madrid, Spain) which is listed as a World Heritage Site by UNESCO since 1998. Portable XRF devices have some detection limits below the ones of the laboratory equipment that are immovable and require sampling. In order to correlate the results, sampling and grinding were initially done to prepare the powders for the laboratory XRF analysis with the following elements: Si, Al, Fe, Ca, Mg, K, Ti, Nb, Zr, Sr, Rb, Pb, Zn and Cr. The analyses of the powdered samples were conducted with the laboratory equipment PHILIPS Magix Pro (PW-2440) from the Centre of Scientific Instrumentation CIC in the University of Granada, and the results were compared to the results gathered with X Ray Florescence (EDTRX) THERMO NITON model XL3T from the Petrophysics Laboratory Geosciences Institute IGEO (CSIC-UCM). Analyses were performed on the surfaces of the samples -without any previous preparation-, and on the powdered samples to compare the variations between both traditional XRF analyses and the portable XRF. A good correlation was found among the results obtained by the laboratory equipment, the portable device as well as the surface measurements. The results of this study enable to differentiate the types of lime mortars used in the site (Caementicium and Signinum) and in different buildings that form the Roman city. Acknowledgements: Thanks to the project CLIMORTEC (BIA2014-53911-R), to CEI-Moncloa of UCM-UPM-UCM and to Madrid Community for funding the Geomateriales2 (P2013/MIT2914) program
Lawryk, Nicholas J; Feng, H Amy; Chen, Bean T
2009-07-01
Recent advances in field-portable X-ray fluorescence (FP XRF) spectrometer technology have made it a potentially valuable screening tool for the industrial hygienist to estimate worker exposures to airborne metals. Although recent studies have shown that FP XRF technology may be better suited for qualitative or semiquantitative analysis of airborne lead in the workplace, these studies have not extensively addressed its ability to measure other elements. This study involved a laboratory-based evaluation of a representative model FP XRF spectrometer to measure elements commonly encountered in workplace settings that may be collected on air sample filter media, including chromium, copper, iron, manganese, nickel, lead, and zinc. The evaluation included assessments of (1) response intensity with respect to location on the probe window, (2) limits of detection for five different filter media, (3) limits of detection as a function of analysis time, and (4) bias, precision, and accuracy estimates. Teflon, polyvinyl chloride, polypropylene, and mixed cellulose ester filter media all had similarly low limits of detection for the set of elements examined. Limits of detection, bias, and precision generally improved with increasing analysis time. Bias, precision, and accuracy estimates generally improved with increasing element concentration. Accuracy estimates met the National Institute for Occupational Safety and Health criterion for nearly all the element and concentration combinations. Based on these results, FP XRF spectrometry shows potential to be useful in the assessment of worker inhalation exposures to other metals in addition to lead.
NASA Astrophysics Data System (ADS)
Tykot, Robert
A portable, hand-held X-ray fluorescence spectrometer has been used for a decade to elementally analyze prehistoric obsidian artifacts in the Mediterranean. Nearly 400 geological obsidian samples and 7500 obsidian artifacts have been analyzed. The pXRF can distinguish all individual sources, as well as assign artifacts specifically to most subsources. For the island sources of Lipari, Pantelleria, Sardinia, and Melos, it is important to address the usage of obsidian from specific subsources due to human selection based on physical properties of the raw material and their production practices, which may have changed over time from the Early Neolithic to the Bronze Age. The analysis of 50 or more artifacts from 60 different archaeological sites allows for statistical comparison between sites, and their contexts, geographic areas (e.g. coastal/inland, highland/lowland) and distance from geological sources. The frequency of transport between island sources and mainland sites is suggestive of maritime capabilities also for the transport of domesticated animals, ceramics, and other materials. This presentation will specifically address potential limitations of the portable XRF, including non-destructive surface analysis of potentially heterogeneous materials, and limited trace element detection compared to other analytical methods, versus its highly beneficial ``package'' of analyzing great numbers of artifacts non-destructively and rapidly without needing to export them from museums and facilities in many countries.
Portable x-ray fluorescence spectrometer for environmental monitoring of inorganic pollutants
NASA Technical Reports Server (NTRS)
Clark, III, Benton C. (Inventor); Thornton, Michael G. (Inventor)
1991-01-01
A portable x-ray fluorescence spectrometer has a portable sensor unit containing a battery, a high voltage power supply, an x-ray tube which produces a beam x-ray radiation directed toward a target sample, and a detector for fluorescent x-rays produced by the sample. If a silicon-lithium detector is used, the sensor unit also contains either a thermoelectric or thermochemical cooler, or a small dewar flask containing liquid nitrogen to cool the detector. A pulse height analyzer (PHA) generates a spectrum of data for each sample consisting of the number of fluorescent x-rays detected as a function of their energy level. The PHA can also store spectrum data for a number of samples in the field. A processing unit can be attached to the pulse height analyzer to upload and analyze the stored spectrum data for each sample. The processing unit provides a graphic display of the spectrum data for each sample, and provides qualitative and/or quantitative analysis of the elemental composition of the sample by comparing the peaks in the sample spectrum against known x-ray energies for various chemical elements. An optional filtration enclosure can be used to filter particles from a sample suspension, either in the form of a natural suspension or a chemically created precipitate. The sensor unit is then temporarily attached to the filtration unit to analyze the particles collected by the filter medium.
Rapid determination of lead for industrial hygiene surveys
NASA Astrophysics Data System (ADS)
Schneider, E. W.; Hill, R. F.
1982-02-01
Emphasis on the continued reduction of personnel exposure to airborne lead has led to the development and evaluation of portable instrumentation for the rapid determination of microgram quantities of lead collected on air filter samples. The instrumentation is based on radioisotope-induced X-ray fluorescence; a cadmium-109 radioisotope source is used for sample excitation, and the characteristic lead X-rays emitted are measured by a proportional detector. The effects of excitation source geometry, particle size, and interferences from other elements were investigated. This type of portable instrumentation appears ideally suited for in-plant measurements intended to monitor lead and evaluate new control measures.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Ying, E-mail: liu.ying.48r@st.kyoto-u.ac.jp; Imashuku, Susumu; Sasaki, Nobuharu
In this study, a portable total reflection x-ray fluorescence (TXRF) spectrometer was used to analyze unknown laboratory hazards that precipitated on exterior surfaces of cooling pipes and fume hood pipes in chemical laboratories. With the aim to examine the accuracy of TXRF analysis for the determination of elemental composition, analytical results were compared with those of wavelength-dispersive x-ray fluorescence spectrometry, scanning electron microscope and energy-dispersive x-ray spectrometry, energy-dispersive x-ray fluorescence spectrometry, inductively coupled plasma atomic emission spectrometry, x-ray diffraction spectrometry (XRD), and x-ray photoelectron spectroscopy (XPS). Detailed comparison of data confirmed that the TXRF method itself was not sufficient tomore » determine all the elements (Z > 11) contained in the samples. In addition, results suggest that XRD should be combined with XPS in order to accurately determine compound composition. This study demonstrates that at least two analytical methods should be used in order to analyze the composition of unknown real samples.« less
Neff, Hector; Bigney, Scott J; Sakai, Sachiko; Burger, Paul R; Garfin, Timothy; George, Richard G; Culleton, Brendan J; Kennett, Douglas J
2016-01-01
Archaeological sediments from mounds within the mangrove zone of far-southern Pacific coastal Chiapas, Mexico, are characterized in order to test the hypothesis that specialized pyro-technological activities of the region's prehistoric inhabitants (salt and ceramic production) created the accumulations visible today. Fourier transform infrared spectroscopy (FT-IR) is used to characterize sediment mineralogy, while portable X-ray fluorescence (pXRF) is used to determine elemental concentrations. Elemental characterization of natural sediments by both instrumental neutron activation analysis (INAA) and pXRF also contribute to understanding of processes that created the archaeological deposits. Radiocarbon dates combined with typological analysis of ceramics indicate that pyro-industrial activity in the mangrove zone peaked during the Late Formative and Terminal Formative periods, when population and monumental activity on the coastal plain and piedmont were also at their peaks. © The Author(s) 2015.
Lightweight Phase-Change Material For Solar Power
NASA Technical Reports Server (NTRS)
Stark, Philip
1993-01-01
Lightweight panels containing phase-change materials developed for use as heat-storage elements of compact, lightweight, advanced solar dynamic power system. During high insolation, heat stored in panels via latent heat of fusion of phase-change material; during low insolation, heat withdrawn from panels. Storage elements consist mainly of porous carbon-fiber structures imbued with germanium. Developed for use aboard space station in orbit around Earth, also adapted to lightweight, compact, portable solar-power systems for use on Earth.
Laohaudomchok, Wisanti; Cavallari, Jennifer M.; Fang, Shona C.; Lin, Xihong; Herrick, Robert F.; Christiani, David C.; Weisskopf, Marc G.
2011-01-01
Elemental analysis of welding fume samples can be done using several laboratory-based techniques. However, portable measurement techniques could offer several advantages. In this study, we sought to determine whether the portable X-ray fluorescence spectrometer (XRF) is suitable for analysis of five metals (manganese, iron, zinc, copper, and chromium) on 37-mm polytetrafluoroethylene filters. Using this filter fitted on a cyclone in line with a personal pump, gravimetric samples were collected from a group of boilermakers exposed to welding fumes. We assessed the assumption of uniform deposition of these metals on the filters, and the relationships between measurement results of each metal obtained from traditional laboratory-based XRF and the portable XRF. For all five metals of interest, repeated measurements with the portable XRF at the same filter area showed good consistency (reliability ratios are equal or close to 1.0 for almost all metals). The portable XRF readings taken from three different areas of each filter were not significantly different (p-values = 0.77 to 0.98). This suggested that the metal rich PM2.5 deposits uniformly on the samples collected using this gravimetric method. For comparison of the two XRFs, the results from the portable XRF were well correlated and highly predictive of those from the laboratory XRF. The Spearman correlation coefficients were from 0.325 for chromium, to 0.995 for manganese and 0.998 for iron. The mean differences as a percent of the mean laboratory XRF readings were also small (<5%) for manganese, iron, and copper. The differences were greater for zinc and chromium, which were present at very low amounts in our samples and below the limits of detection of the portable XRF for many of the samples. These five metals were moderately to strongly correlated with the total fine particle fraction on filters (Spearman ρ = 0.41 for zinc to 0.97 for iron). Such strong correlations and comparable results suggested that the portable XRF could be used as an effective and reliable tool for exposure assessment in many studies. PMID:20526948
Laohaudomchok, Wisanti; Cavallari, Jennifer M; Fang, Shona C; Lin, Xihong; Herrick, Robert F; Christiani, David C; Weisskopf, Marc G
2010-08-01
Elemental analysis of welding fume samples can be done using several laboratory-based techniques. However, portable measurement techniques could offer several advantages. In this study, we sought to determine whether the portable X-ray fluorescence spectrometer (XRF) is suitable for analysis of five metals (manganese, iron, zinc, copper, and chromium) on 37-mm polytetrafluoroethylene filters. Using this filter fitted on a cyclone in line with a personal pump, gravimetric samples were collected from a group of boilermakers exposed to welding fumes. We assessed the assumption of uniform deposition of these metals on the filters, and the relationships between measurement results of each metal obtained from traditional laboratory-based XRF and the portable XRF. For all five metals of interest, repeated measurements with the portable XRF at the same filter area showed good consistency (reliability ratios are equal or close to 1.0 for almost all metals). The portable XRF readings taken from three different areas of each filter were not significantly different (p-values = 0.77 to 0.98). This suggested that the metal rich PM(2.5) deposits uniformly on the samples collected using this gravimetric method. For comparison of the two XRFs, the results from the portable XRF were well correlated and highly predictive of those from the laboratory XRF. The Spearman correlation coefficients were from 0.325 for chromium, to 0.995 for manganese and 0.998 for iron. The mean differences as a percent of the mean laboratory XRF readings were also small (<5%) for manganese, iron, and copper. The differences were greater for zinc and chromium, which were present at very low amounts in our samples and below the limits of detection of the portable XRF for many of the samples. These five metals were moderately to strongly correlated with the total fine particle fraction on filters (Spearman rho = 0.41 for zinc to 0.97 for iron). Such strong correlations and comparable results suggested that the portable XRF could be used as an effective and reliable tool for exposure assessment in many studies.
Development of a Portable Taste Sensor with a Lipid/Polymer Membrane
Tahara, Yusuke; Nakashi, Kenichi; Ji, Ke; Ikeda, Akihiro; Toko, Kiyoshi
2013-01-01
We have developed a new portable taste sensor with a lipid/polymer membrane and conducted experiments to evaluate the sensor's performance. The fabricated sensor consists of a taste sensor chip (40 mm × 26 mm × 2.2 mm) with working and reference electrodes and a portable sensor device (80 mm × 25 mm × 20 mm). The working electrode consists of a taste-sensing site comprising a poly(hydroxyethyl)methacrylate (pHEMA) hydrogel layer with KCl as the electrolyte layer and a lipid/polymer membrane as the taste sensing element. The reference electrode comprises a polyvinyl chloride (PVC) membrane layer with a small hole and a pHEMA layer with KCl. The whole device is the size of a USB memory stick, making it suitable for portable use. The sensor's response to tannic acid as the standard astringency substance showed good accuracy and reproducibility, and was comparable with the performance of a commercially available taste sensing system. Thus, it is possible for this sensor to be used for in-field evaluations and it can make a significant contribution to the food industry, as well as in various fields of research. PMID:23325168
Use of nuclear techniques to determine the fill of found unexploded ordnance.
Steward, Scott; Forsht, Denice
2005-01-01
The PELAN is a man-portable device that uses pulsed neutrons to interrogate objects in order to determine their filler. The neutrons initiate several types of nuclear reactions within the object under scrutiny, which result in the formation of gamma rays. The energy of the resulting gamma rays provides information about the elements (carbon, hydrogen, oxygen, nitrogen) contained within the object; in addition the number of gamma rays detected provides information about how much of each element is present. An analysis of the elements present and their ratios to one another allows for identification of the filler material.
49 CFR 236.587 - Departure test.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 49 Transportation 4 2014-10-01 2014-10-01 false Departure test. 236.587 Section 236.587..., Train Control and Cab Signal Systems Inspection and Tests; Locomotive § 236.587 Departure test. (a) The...: (1) Operation over track elements; (2) Operation over test circuit; (3) Use of portable test...
49 CFR 236.587 - Departure test.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 4 2010-10-01 2010-10-01 false Departure test. 236.587 Section 236.587..., Train Control and Cab Signal Systems Inspection and Tests; Locomotive § 236.587 Departure test. (a) The...: (1) Operation over track elements; (2) Operation over test circuit; (3) Use of portable test...
47 CFR 51.5 - Terms and definitions.
Code of Federal Regulations, 2012 CFR
2012-10-01
... number portability in conjunction with other functions and services. Enhanced extended link. An enhanced..., together with any facilities, equipment, or functions necessary to combine those network elements.... For the purposes of section 251(c)(3) of the Act, the equipment used to gain access to an incumbent...
Methods for identification and verification using vacuum XRF system
NASA Technical Reports Server (NTRS)
Kaiser, Bruce (Inventor); Schramm, Fred (Inventor)
2005-01-01
Apparatus and methods in which one or more elemental taggants that are intrinsically located in an object are detected by x-ray fluorescence analysis under vacuum conditions to identify or verify the object's elemental content for elements with lower atomic numbers. By using x-ray fluorescence analysis, the apparatus and methods of the invention are simple and easy to use, as well as provide detection by a non line-of-sight method to establish the origin of objects, as well as their point of manufacture, authenticity, verification, security, and the presence of impurities. The invention is extremely advantageous because it provides the capability to measure lower atomic number elements in the field with a portable instrument.
Reduced size fuel cell for portable applications
NASA Technical Reports Server (NTRS)
Narayanan, Sekharipuram R. (Inventor); Valdez, Thomas I. (Inventor); Clara, Filiberto (Inventor); Frank, Harvey A. (Inventor)
2004-01-01
A flat pack type fuel cell includes a plurality of membrane electrode assemblies. Each membrane electrode assembly is formed of an anode, an electrolyte, and an cathode with appropriate catalysts thereon. The anode is directly into contact with fuel via a wicking element. The fuel reservoir may extend along the same axis as the membrane electrode assemblies, so that fuel can be applied to each of the anodes. Each of the fuel cell elements is interconnected together to provide the voltage outputs in series.
Hagen, R. W.; Ambos, H. D.; Browder, M. W.; Roloff, W. R.; Thomas, L. J.
1979-01-01
The Clinical Physiologic Research System (CPRS) developed from our experience in applying computers to medical instrumentation problems. This experience revealed a set of applications with a commonality in data acquisition, analysis, input/output, and control needs that could be met by a portable system. The CPRS demonstrates a practical methodology for integrating commercial instruments with distributed modular elements of local design in order to make facile responses to changing instrumentation needs in clinical environments. ImagesFigure 3
49 CFR 173.411 - Industrial packages.
Code of Federal Regulations, 2014 CFR
2014-10-01
...) Each Type IP-1 package must meet the general design requirements prescribed in § 173.410. (2) Each Type IP-2 package must meet the general design requirements prescribed in § 173.410 and when subjected to...), “Requirements for the Design, Construction, Inspection and Testing of Portable Tanks and Multiple-Element Gas...
LCD Projectors: An Evaluation of Features and Utilization for Educators.
ERIC Educational Resources Information Center
Fawson, Curtis E.
1990-01-01
Describes liquid crystal display (LCD) projectors and discusses their use in educational settings. Highlights include rear screen projection; LCD projectors currently available and the number of pixel elements in each; and examples of instructional applications, including portable setups, and use with videocassette recorders (VCRs), computers, and…
40 CFR 59.680 - What definitions apply to this subpart?
Code of Federal Regulations, 2011 CFR
2011-07-01
... design that controls or reduces the regulated evaporative emissions from. Emission-data unit means a... PRODUCTS Control of Evaporative Emissions From New and In-Use Portable Fuel Containers Definitions and... amended, 42 U.S.C. 7401-7671q. Adjustable parameter means any device, system, or element of design that...
NASA Technical Reports Server (NTRS)
Rodriquez, Branelle; Graf, John; Carlile, Christie; Young, GIna
2012-01-01
The National Aeronautics and Space Administration (NASA) is developing a Fine Water Mist (FWM) Portable Fire Extinguisher (PFE) for use on the International Space Station (ISS). The ISS presently uses two different types of fire extinguishers: a water foam extinguisher in the Russian Segment, and a carbon dioxide extinguisher in the United States Orbital Segments, which include Columbus and Kibo pressurized elements. Currently, there are operational concerns with the emergency breathing equipment and the carbon dioxide extinguisher. The toxicity of the carbon dioxide requires the crew members to have an oxygen supply present during a fire event, therefore inherently creating an unsafe environment. The FWM PFE extinguishes a fire without creating a hazardous breathing environment for crew members. The following paper will discuss the unique functional and performance requirements that have been levied on the FWM PFE, identify unique microgravity design considerations for liquid and gas systems, as well as discuss the NASA ISS specific fire standards that were developed to establish an acceptable portable fire extinguisher s performance.
Portable Imagery Quality Assessment Test Field for Uav Sensors
NASA Astrophysics Data System (ADS)
Dąbrowski, R.; Jenerowicz, A.
2015-08-01
Nowadays the imagery data acquired from UAV sensors are the main source of all data used in various remote sensing applications, photogrammetry projects and in imagery intelligence (IMINT) as well as in other tasks as decision support. Therefore quality assessment of such imagery is an important task. The research team from Military University of Technology, Faculty of Civil Engineering and Geodesy, Geodesy Institute, Department of Remote Sensing and Photogrammetry has designed and prepared special test field- The Portable Imagery Quality Assessment Test Field (PIQuAT) that provides quality assessment in field conditions of images obtained with sensors mounted on UAVs. The PIQuAT consists of 6 individual segments, when combined allow for determine radiometric, spectral and spatial resolution of images acquired from UAVs. All segments of the PIQuAT can be used together in various configurations or independently. All elements of The Portable Imagery Quality Assessment Test Field were tested in laboratory conditions in terms of their radiometry and spectral reflectance characteristics.
DEMONSTRATION AND QUALITY ASSURANCE PROJECT ...
A demonstration of field portable/mobile technologies for measuring trace elements in soil and sediments was conducted under the U.S. Environmental Protection Agency Superfund Innovative Technology Evaluation (SITE) Program. The demonstration took place from January 24 to 28, 2005, at the Kennedy Athletic, Recreational and Social Park at Kennedy Space Center on Merritt Island, Florida. The purpose of the demonstration was to verify the performance of various instruments that employ X-ray fluorescence (XRF) measurement technologies for the determination of 13 toxic elements in a variety of soil and sediment samples. Instruments from the technology developers listed below were demonstrated. o Innov-X Systems, Inc.o NITON LLC (2 instruments ) o Oxford Instruments Portable Division (formerly Metorex, Inc.) .Oxford Instruments Analytical .Rigaku, Inc.o RONTEC USA Inc.o Xcalibur XRF Services Inc. (Division of Elvatech Ltd. ) This demonstration plan describes the procedures that will be used to verify the performance and cost of the XRF instruments provided by these technology developers. The plan incorporates the quality assurance and quality control elements needed to generate data of sufficient quality to perform this verification. A separate innovative technology verification report (ITVR) will be prepared for each instrument. The objective of this program is to promote the acceptance and use of innovative field technologies by providing well-documented perfor
NASA Astrophysics Data System (ADS)
Bártová, H.; Trojek, T.; Čechák, T.; Šefců, R.; Chlumská, Š.
2017-10-01
The presence of heavy chemical elements in old pigments is possible to identify in historical paintings using X-ray fluorescence analysis (XRF). This is a non-destructive analytical method frequently used in examination of objects that require in situ analysis, where it is necessary to avoid damaging the object by taking samples. Different modalities are available, such as microanalysis, scanning selected areas, or depth profiling techniques. Surface scanning is particularly profitable since 2D element distribution maps are much more understandable than the results of individual analyses. Information on the layered structure of the painting can be also obtained by handheld portable systems. Results presented in our paper combine 2D element distribution maps obtained by scanning analysis, and depth profiling using conventional XRF. The latter is very suitable for objects of art, as it can be evaluated from data measured with portable XRF device. Depth profiling by conventional XRF is based on the differences in X-ray absorption in paint layers. The XRF technique was applied for analysis of panel paintings of the Master of the St George Altarpiece who was active in Prague in the 1470s and 1480s. The results were evaluated by taking micro-samples and performing a material analysis.
A miniature fuel reformer system for portable power sources
NASA Astrophysics Data System (ADS)
Dolanc, Gregor; Belavič, Darko; Hrovat, Marko; Hočevar, Stanko; Pohar, Andrej; Petrovčič, Janko; Musizza, Bojan
2014-12-01
A miniature methanol reformer system has been designed and built to technology readiness level exceeding a laboratory prototype. It is intended to feed fuel cells with electric power up to 100 W and contains a complete setup of the technological elements: catalytic reforming and PROX reactors, a combustor, evaporators, actuation and sensing elements, and a control unit. The system is engineered not only for performance and quality of the reformate, but also for its lightweight and compact design, seamless integration of elements, low internal electric consumption, and safety. In the paper, the design of the system is presented by focussing on its miniaturisation, integration, and process control.
NASA Astrophysics Data System (ADS)
Van de Voorde, Lien; Vandevijvere, Melissa; Vekemans, Bart; Van Pevenage, Jolien; Caen, Joost; Vandenabeele, Peter; Van Espen, Piet; Vincze, Laszlo
2014-12-01
The most unique and only known 16th century Antwerp majolica tile floor in Belgium is situated in a tower of the Rameyenhof castle (Gestel, Belgium). This exceptional work of art has recently been investigated in situ by using X-ray fluorescence (XRF) and Raman spectroscopy in order to study the material characteristics. This study reports on the result of the analyses based on the novel combination of non-destructive and portable instrumentation, including a handheld XRF spectrometer for obtaining elemental information and a mobile Raman spectrometer for retrieving structural and molecular information on the floor tiles in the Rameyenhof castle and on a second, similar medallion, which is stored in the Rubens House museum in Antwerp (Belgium). The investigated material, majolica, is a type of ceramic, which fascinated many people and potters throughout history by its beauty and colourful appearance. In this study the characteristic major/minor and trace element signature of 16th century Antwerp majolica is determined and the pigments used for the colourful paintings present on the floor are identified. Furthermore, based on the elemental fingerprint of the white glaze, and in particular on the presence of zinc in the tiles - an element that was not used for making 16th century majolica - valuable information about the originality of the chapel floor and the two central medallions is acquired.
Drop-in Security for Distributed and Portable Computing Elements.
ERIC Educational Resources Information Center
Prevelakis, Vassilis; Keromytis, Angelos
2003-01-01
Proposes the use of a special purpose drop-in firewall/VPN gateway called Sieve, that can be inserted between the mobile workstation and the network to provide individualized security services for that particular station. Discusses features and advantages of the system and demonstrates how Sieve was used in various application areas such as at…
Volatile metal species in coal combustion flue gas.
Pavageau, Marie-Pierre; Pécheyran, Christophe; Krupp, Eva M; Morin, Anne; Donard, Olivier F X
2002-04-01
Metals are released in effluents of most of combustion processes and are under intensive regulations. To improve our knowledge of combustion process and their resulting emission of metal to the atmosphere, we have developed an approach allowing usto distinguish between gaseous and particulate state of the elements emitted. This study was conducted on the emission of volatile metallic species emitted from a coal combustion plant where low/medium volatile coal (high-grade ash) was burnt. The occurrence of volatile metal species emission was investigated by cryofocusing sampling procedure and detection using low-temperature packed-column gas chromatography coupled with inductively coupled plasma-mass spectrometry as multielement detector (LT-GC/ICP-MS). Samples were collected in the stack through the routine heated sampling line of the plant downstream from the electrostatic precipitator. The gaseous samples were trapped with a cryogenic device and analyzed by LT-GC/ICP-MS. During the combustion process, seven volatile metal species were detected: three for Se, one for Sn, two for Hg, and one for Cu. Thermodynamic calculations and experimental metal species spiking experiments suggest that the following volatile metal species are present in the flue gas during the combustion process: COSe, CSSe, CSe2, SeCl2, Hg0, HgCl2, CuO-CuSO4 or CuSO4 x H2O, and SnO2 or SnCl2. The quantification of volatile species was compared to results traditionally obtained by standardized impinger-based sampling and analysis techniques recommended for flue gas combustion characterization. Results showed that concentrations obtained with the standard impinger approach are at least 10 times higher than obtained with cryogenic sampling, suggesting the trapping microaerosols in the traditional methods. Total metal concentrations in particles are also reported and discussed.
Jian, Wen-Shan; Hsu, Chien-Yeh; Hao, Te-Hui; Wen, Hsyien-Chia; Hsu, Min-Huei; Lee, Yen-Liang; Li, Yu-Chuan; Chang, Polun
2007-11-01
Traditional electronic health record (EHR) data are produced from various hospital information systems. They could not have existed independently without an information system until the incarnation of XML technology. The interoperability of a healthcare system can be divided into two dimensions: functional interoperability and semantic interoperability. Currently, no single EHR standard exists that provides complete EHR interoperability. In order to establish a national EHR standard, we developed a set of local EHR templates. The Taiwan Electronic Medical Record Template (TMT) is a standard that aims to achieve semantic interoperability in EHR exchanges nationally. The TMT architecture is basically composed of forms, components, sections, and elements. Data stored in the elements which can be referenced by the code set, data type, and narrative block. The TMT was established with the following requirements in mind: (1) transformable to international standards; (2) having a minimal impact on the existing healthcare system; (3) easy to implement and deploy, and (4) compliant with Taiwan's current laws and regulations. The TMT provides a basis for building a portable, interoperable information infrastructure for EHR exchange in Taiwan.
Rapid Analysis of Copper Ore in Pre-Smelter Head Flow Slurry by Portable X-ray Fluorescence.
Burnett, Brandon J; Lawrence, Neil J; Abourahma, Jehad N; Walker, Edward B
2016-05-01
Copper laden ore is often concentrated using flotation. Before the head flow slurry can be smelted, it is important to know the concentration of copper and contaminants. The concentration of copper and other elements fluctuate significantly in the head flow, often requiring modification of the concentrations in the slurry prior to smelting. A rapid, real-time analytical method is needed to support on-site optimization of the smelter feedstock. A portable, handheld X-ray fluorescence spectrometer was utilized to determine the copper concentration in a head flow suspension at the slurry origin. The method requires only seconds and is reliable for copper concentrations of 2.0-25%, typically encountered in such slurries. © The Author(s) 2016.
NASA Astrophysics Data System (ADS)
Gärtner, Claudia; Sewart, René; Klemm, Richard; Becker, Holger
2014-06-01
A portable analytical system for the characterization of liquid environmental samples and beverages in food control was realized. The key element is the implementation of contactless conductivity detection on lab-on-a-chip basis ensuring the system to be operated in a label free mode. Typical target molecules such as small ionic species like Li+, Na+, K+, SO4 2- or NO3-, organic acids in wine whose concentration and ratio to each other documents the wine quality, or caffeine or phosphate in coke were detected. Results from sample matrices like various beverages as water, cola, tea, wine and milk, water from heaters, environmental samples and blood will be presented.
NASA Astrophysics Data System (ADS)
Duan, Yixiang; Su, Yongxuan; Jin, Zhe; Abeln, Stephen P.
2000-03-01
The development of a highly sensitive, field portable, low-powered instrument for on-site, real-time liquid waste stream monitoring is described in this article. A series of factors such as system sensitivity and portability, plasma source, sample introduction, desolvation system, power supply, and the instrument configuration, were carefully considered in the design of the portable instrument. A newly designed, miniature, modified microwave plasma source was selected as the emission source for spectroscopy measurement, and an integrated small spectrometer with a charge-coupled device detector was installed for signal processing and detection. An innovative beam collection system with optical fibers was designed and used for emission signal collection. Microwave plasma can be sustained with various gases at relatively low power, and it possesses high detection capabilities for both metal and nonmetal pollutants, making it desirable to use for on-site, real-time, liquid waste stream monitoring. An effective in situ sampling system was coupled with a high efficiency desolvation device for direct-sampling liquid samples into the plasma. A portable computer control system is used for data processing. The new, integrated instrument can be easily used for on-site, real-time monitoring in the field. The system possesses a series of advantages, including high sensitivity for metal and nonmetal elements; in situ sampling; compact structure; low cost; and ease of operation and handling. These advantages will significantly overcome the limitations of previous monitoring techniques and make great contributions to environmental restoration and monitoring.
Elemental assessment of vegetation via portable X-ray fluorescence (PXRF) spectrometry.
McGladdery, Candice; Weindorf, David C; Chakraborty, Somsubhra; Li, Bin; Paulette, Laura; Podar, Dorina; Pearson, Delaina; Kusi, Nana Yaw O; Duda, Bogdan
2018-03-15
Elemental concentrations in vegetation are of critical importance, whether establishing plant essential element concentrations (toxicity vs. deficiency) or investigating deleterious elements (e.g., heavy metals) differentially extracted from the soil by plants. Traditionally, elemental analysis of vegetation has been facilitated by acid digestion followed by quantification via inductively coupled plasma (ICP) or atomic absorption (AA) spectroscopy. Previous studies have utilized portable X-ray fluorescence (PXRF) spectroscopy to quantify elements in soils, but few have evaluated the vegetation. In this study, a PXRF spectrometer was employed to scan 228 organic material samples (thatch, deciduous leaves, grasses, tree bark, and herbaceous plants) from smelter-impacted areas of Romania, as well as National Institute of Standards and Technology (NIST) certified reference materials, to demonstrate the application of PXRF for elemental determination in vegetation. Samples were scanned in three conditions: as received from the field (moist), oven dry (70 °C), and dried and powdered to pass a 2 mm sieve. Performance metrics of PXRF models relative to ICP atomic emission spectroscopy were developed to asses optimal scanning conditions. Thatch and bark samples showed the highest mean PXRF and ICP concentrations (e.g., Zn, Pb, Cd, Fe), with the exceptions of K and Cl. Validation statistics indicate that the stable validation predictive capacity of PXRF increased in the following order: oven dry intact < field moist < oven dried and powdered. Even under field moist conditions, PXRF could reasonably be used for the determination of Zn (coefficient of determination, R 2 val 0.86; residual prediction deviation, RPD 2.72) and Cu (R 2 val 0.77; RPD 2.12), while dried and powdered samples allowed for stable validation prediction of Pb (R 2 val 0.90; RPD 3.29), Fe (R 2 val 0.80; RPD 2.29), Cd (R 2 val 0.75; RPD 2.07) and Cu (R 2 val 0.98; RPD of 8.53). Summarily, PXRF was shown to be a useful approach for quickly assessing the elemental concentration in vegetation. Future PXRF/vegetation research should explore additional elements and investigate its usefulness in evaluating phytoremediation effectiveness. Copyright © 2018 Elsevier Ltd. All rights reserved.
A portable bioluminescence engineered cell-based biosensor for on-site applications.
Roda, Aldo; Cevenini, Luca; Michelini, Elisa; Branchini, Bruce R
2011-04-15
We have developed a portable biosensing device based on genetically engineered bioluminescent (BL) cells. Cells were immobilized on a 4 × 3 multiwell cartridge using a new biocompatible matrix that preserved their vitality. Using a fiber optic taper, the cartridge was placed in direct contact with a cooled CCD sensor to image and quantify the BL signals. Yeast and bacterial cells were engineered to express recognition elements, whose interaction with the analyte led to luciferase expression, via reporter gene technology. Three different biosensors were developed. The first detects androgenic compounds using yeast cells carrying a green-emitting P. pyralis luciferase regulated by the human androgen receptor and a red mutant of the same species as internal vitality control. The second biosensor detects two classes of compounds (androgens and estrogens) using yeast strains engineered to express green-or red-emitting mutant firefly luciferases in response to androgens or estrogens, respectively. The third biosensor detects lactose analogue isopropyl β-d-1-thiogalactopyranoside using two E. coli strains. One strain exploits the lac operon as recognition element for the expression of P. pyralis luciferase. The other strain serves as a vitality control expressing Gaussia princeps luciferase, which requires a different luciferin substrate. The immobilized cells were stable for up to 1 month. The analytes could be detected at nanomolar levels with good precision and accuracy when the specific signal was corrected using the internal vitality control. This portable device can be used for on-site multiplexed bioassays for different compound classes. Copyright © 2011 Elsevier B.V. All rights reserved.
One-port portable SAW sensor system
NASA Astrophysics Data System (ADS)
Hoa Nguyen, Vu; Peters, Oliver; Schnakenberg, Uwe
2018-01-01
A portable device using the SAW-based impedance sensor type based on one interdigital transducer simultaneously as SAW generator and sensor element (1-port approach) is introduced. As a novelty, the so far required expensive vector network analyzer (VNA) is replaced by a hand-held device to measure the impedance spectrum of the SAW sensor by RF-gain-phase meters. Hence, some of the best features from the conventional oscillator and VNA approaches are combined to develop a low-cost and self-contained measurement system, including signal in- and output ability for real-time measurements. The pivotal aspect of the portable system is the transfer of the sophisticated high frequency approach into a quasi-static one. This enables the use of simple lumped electronics without the need of impedance matching circuits. Proof-of-concept was carried out by measuring conductivities of phosphate-buffered solutions and viscosities of glycerin. Sensitivities for temperature of 0.3%/°C, viscosity of 10.1% (mPa s)-1 and conductivity of 0.5% (S cm)-1 have been determined, respectively, which are competitive results compared to the benchmark approaches.
ERIC Educational Resources Information Center
Palmer, Peter T.
2011-01-01
Portable Energy-Dispersive X-Ray Fluorescence (XRF) analyzers have undergone significant improvements over the past decade. Salient advantages of XRF for elemental analysis include minimal sample preparation, multielement analysis capabilities, detection limits in the low parts per million (ppm) range, and analysis times on the order of 1 min.…
X-ray chemical analyzer for field applications
Gamba, Otto O. M.
1977-01-01
A self-supporting portable field multichannel X-ray chemical analyzer system comprising a lightweight, flexibly connected, remotely locatable, radioisotope-excited sensing probe utilizing a cryogenically-cooled solid state semi-conductor crystal detector for fast in situ non-destructive, qualitative and quantitative analysis of elements in solid, powder, liquid or slurried form, utilizing an X-ray energy dispersive spectrometry technique.
ERIC Educational Resources Information Center
Morra, Linda G.
A study reviewed eight standards and certification systems for occupations that required less than a bachelor's degree for entry-level employment. Common elements among systems included industry ownership and control, recertification requirements to keep certificate holders' skills current, national portability of credentials, and integration of…
Origin of the Chemical Elements and Their Discoveries [added 1/2007] National Laboratories and Other to the content of DOE R&D Accomplishments. Celebrating Einstein - series of articles about Albert Einstein and his work [added 3/2005] Compact Portable Electric Power Sources [added 1/2007] History of the
USDA-ARS?s Scientific Manuscript database
The use of field effect transistors (FETs) as the transduction element for the detection of DNA amplification reactions will enable portable and inexpensive nucleic acid analysis. Transistors used as biological sensors,or BioFETs, minimize the cost and size of detection platforms by leveraging fabri...
NASA Astrophysics Data System (ADS)
Mohamed, Walid Tawfik Y.
2008-02-01
Laser-induced breakdown spectroscopy (LIBS) is a laser-based technique that can provide non-intrusive, qualitative and quantitative measurement of metals in various environments. LIBS uses the plasma generated by a high-energy laser beam to prepare and excite the sample in one step. In the present work, LIBS has been applied to perform elemental analysis of six trace elements simultaneously in aluminum alloy targets. The plasma is generated by focusing a pulsed Nd:YAG laser on the target in air at atmospheric pressure. LIBS limit of detection (LOD) is affected by many experimental parameters such as interferences, self-absorption, spectral overlap and matrix effect. We aimed to improve the LIBS LOD by optimizing these experimental parameters as possible. In doing so, a portable Echelle spectrometer with intensified CCD camera was used to detect the LIBS plasma emission. This advanced Echelle spectrometer provides a constant spectral resolution (CSR) of 7500 corresponding to 4 pixels FWHM over a wavelength range 200-1000 nm displayable in a single spectrum. Then, the calibration curves for iron, beryllium, magnesium, silicon, manganese and copper as minor elements were achieved with linear regression coefficients between 98-99% on average in aluminum standard sample alloys. New LOD values were achieved in the ppm range with high precision (RSD 3-8%). From the application view point, improving LIBS LOD is very important in the on-line industrial process control to follow-up multi-elements for the correct alloying in metals.
NASA Astrophysics Data System (ADS)
Jordan, B.
2016-12-01
Field-based petrologic research projects often involve multiple field seasons, with geochemical analysis of samples collected in one season informing aspects of subsequent field seasons. To simulate this approach in the Iceland Volcanology Field Camp (South Dakota School of Mines & Technology) a portable X-ray fluorescence spectrometer (pXRF) was employed to provide "laboratory analyses" in support of a course mapping project. The project was conducted in the Árnes central volcano in the Neogene plateau lava succession in the West Fjords of northwestern Iceland. The field area has a wide compositional spectrum from basalt to rhyolite, with abundant intermediates. The pXRF is particularly helpful in the study of these kinds of rocks in Iceland because lithologies can be quite similar across a wide range of compositions (often lacking diagnostic macroscopic phenocryst assemblages, and having similar groundmass characteristics). A Bruker Tracer III-SD pXRF was utilized, operating at 40 KeV and 11.2 μA with no filter. Analyses were conducted at basecamp in the evenings on relatively flat fresh surfaces, with three 30 s analyses of different spots for each sample. A basic empirical calibration was generated with six aphyric samples previously analyzed by laboratory XRF. Light elements Na, Mg, and Al were not determined directly, but were estimated based on linear or polynomial correlations with other elements or elemental ratios (K, Ca, and Sr/Y respectively) determined from a previously obtained laboratory XRF data set for this central volcano. The resulting chemical analyses (normalized to sum to 100%) provided full major and minor element compositions to be used for classification, and several trace elements (V, Sr, Y, Zr) that could potentially distinguish different lavas of similar major element composition. The approach is coarse, and has pitfalls particularly regarding porphyritic rocks, but serves the objectives of the field camp project.
A USB-2 based portable data acquisition system for detector development and nuclear research
NASA Astrophysics Data System (ADS)
Jiang, Hao; Ojaruega, M.; Becchetti, F. D.; Griffin, H. C.; Torres-Isea, R. O.
2011-10-01
A highly portable high-speed CAMAC data acquisition system has been developed using Kmax software (Sparrow, Inc.) for Macintosh laptop and tower computers. It uses a USB-2 interface to the CAMAC crate controller with custom-written software drivers. Kmax permits 2D parameter gating and specific algorithms have been developed to facilitate the rapid evaluation of various multi-element nuclear detectors for energy and time-of-flight measurements. This includes tests using neutrons from 252Cf and a 2.5 MeV neutron generator as well as standard gamma calibration sources such as 60Co and 137Cs. In addition, the system has been used to measure gamma-gamma coincidences over extended time periods using radioactive sources (e.g., Ra-228, Pa-233, Np-237, and Am-243).
A Portable Diode Array Spectrophotometer.
Stephenson, David
2016-05-01
A cheap portable visible light spectrometer is presented. The spectrometer uses readily sourced items and could be constructed by anyone with a knowledge of electronics. The spectrometer covers the wavelength range 450-725 nm with a resolution better than 5 nm. The spectrometer uses a diffraction grating to separate wavelengths, which are detected using a 128-element diode array, the output of which is analyzed using a microprocessor. The spectrum is displayed on a small liquid crystal display screen and can be saved to a micro SD card for later analysis. Battery life (2 × AAA) is estimated to be 200 hours. The overall dimensions of the unit are 120 × 65 × 60 mm, and it weighs about 200 g. © The Author(s) 2016.
NASA Astrophysics Data System (ADS)
Abbaszadeh, Shiva; Karim, Karim S.; Karanassios, Vassili
2013-05-01
Traditionally, samples are collected on-site (i.e., in the field) and are shipped to a lab for chemical analysis. An alternative is offered by using portable chemical analysis instruments that can be used on-site (i.e., in the field). Many analytical measurements by optical emission spectrometry require use of light-sources and of spectral lines that are in the Ultra-Violet (UV, ~200 nm - 400 nm wavelength) region of the spectrum. For such measurements, a portable, battery-operated, fiber-optic spectrometer equipped with an un-cooled, linear, solid-state detector may be used. To take full advantage of the advanced measurement capabilities offered by state-of-the-art solid-state detectors, cooling of the detector is required. But cooling and other thermal management hamper portability and use on-site because they add size and weight and they increase electrical power requirements. To address these considerations, an alternative was implemented, as described here. Specifically, a microfabricated solid-state detector for measurement of UV photons will be described. Unlike solid-state detectors developed on crystalline Silicon, this miniaturized and low-cost detector utilizes amorphous Selenium (a-Se) as its photosensitive material. Due to its low dark current, this detector does not require cooling, thus it is better suited for portable use and for chemical measurements on-site. In this paper, a microplasma will be used as a light-source of UV photons for the a-Se detector. For example, spectra acquired using a microplasma as a light-source will be compared with those obtained with a portable, fiber-optic spectrometer equipped with a Si-based 2080-element detector. And, analytical performance obtained by introducing ng-amounts of analytes into the microplasma will be described.
Portable kit for the assessment of gait parameters in daily telerehabilitation.
Giansanti, Daniele; Morelli, Sandra; Maccioni, Giovanni; Grigioni, Mauro
2013-03-01
When designing a complete process of daily telerehabilitation, it should be borne in mind that patients should be furnished with properly designed methodologies for executing specific motion tasks and the assessment of the relevant parameters. In general, such a process should comprehend three basic elements in both the hospital and the home: (a) instrumented walkways, (b) walking aids or supports, and (c) equipment for the assessment of parameters. The objective, with gait being the focus, of this study was thus to design a simple, portable kit-as an alternative to the complex and expensive instruments currently used-to be easily interfaced or integrated with the instrumented walkways and aids/supports both for self-monitoring while patients are exercising with their own aids and for clinical reporting. The proposed system is a portable kit that furnishes useful parameters with feedback to both the patient and the trainer/therapist. Capable of being integrated with the most common mechanical tools used in motion rehabilitation (handrail, scales, walkways, etc.), it constantly monitors and quantitatively assesses progress in rehabilitation care. It is composed of one step counter, photo-emitter detectors, one central unit for collecting and processing the telemetrically transmitted data, and a software interface. The system has been successfully validated on 16 subjects at the second level of the Tinetti test in a clinical application for both home and the hospital. The portable kit can be used with different rehabilitation tools and on varying ground rugosity. Advantages include (a) very low cost, when compared with optoelectronic solutions or other portable devices, (b) very high accuracy, also for subjects with imbalance problems, compared with other commercial solutions, and (c) integration (compatibility) with any rehabilitative tool.
Development of an ultra-portable echo device connected to USB port.
Saijo, Yoshifumi; Nitta, Shin-ichi; Kobayashi, Kazuto; Arai, Hitoshi; Nemoto, Yukiko
2004-04-01
In practical cardiology, a stethoscope based auscultation has been used to reveal the patient's clinical status. Recently, several hand-held echo devices are going on market and they are expected to play a role as "visible" auscultation instead of stethoscope. We have developed a portable and inexpensive echo device which can be used for screening of cardiac function. Two single element transducers were attached 180 degrees apart to a rotor with 14-mm diameter. The mechanical scanner, integrated circuits for transmitting and receiving ultrasonic signals and an A/D converter were encapsulated in a 150 x 40 mm probe weighing 200 g. The scan was started and the image was displayed on a Windows based personal computer (PC) as soon as the probe was connected to USB 2.0 port of the PC. The central frequency was available between 2.5 and 7.5 MHz, the image depth was 15 cm and the frame rate was 30/s. The estimated price of this ultra-portable ultrasound is about 3000 US dollars with software. For 69 cardiac patients with informed consent, image quality was compared with those obtained with basic range diagnostic echo machines. Left ventricular ejection fraction (EF) derived from normal M-mode image of standard machines (EFm) were compared with visual EF of the ultra-portable ultrasound device (EFv). The image quality was comparable to the basic range diagnostic echo machines although short axis view of aortic root was not clearly visualized because the probe was too large for intercostal approach. EFv agreed well with EFm. The ultra-portable ultrasound may provide useful information on screening and health care.
Quick-Connect, Self-Alining Latch
NASA Technical Reports Server (NTRS)
Burns, G. C.; Williams, E. J.
1983-01-01
Sturdy latch tolerates 10 degrees of angular mismatch in joining structural elements. Hexagonal passive plate nests in active plate, guided by capture plates and alinement keys and grooves. Center hole in both active and passive plates is 1 meter in diameter. Latch has possible uses a pipe joint, connector for parts of portable structures, and fitting for marine risers on offshore drilling rigs.
Development of an alpha scattering instrument for heavy element detection in surface materials
NASA Technical Reports Server (NTRS)
Turkevich, A. L.; Economou, T.; Blume, E.; Anderson, W.
1974-01-01
The development and characteristics of a portable instrument for detecting and measuring the amounts of lead in painted surfaces are discussed. The instrument is based on the ones used with the alpha scattering experiment on the Surveyor lunar missions. The principles underlying the instrument are described. It is stated that the performance tests of the instrument were satisfactory.
Code of Federal Regulations, 2011 CFR
2011-07-01
... inspections b. Portable mercury vapor analyzer—ultraviolet light absorption detector A sample of gas is drawn... detector A sample of gas is drawn through a detection cell containing a gold film detector. Elemental mercury amalgamates with the gold film, changing the resistance of the detector in proportion to the...
Code of Federal Regulations, 2012 CFR
2012-07-01
... inspections b. Portable mercury vapor analyzer—ultraviolet light absorption detector A sample of gas is drawn... detector A sample of gas is drawn through a detection cell containing a gold film detector. Elemental mercury amalgamates with the gold film, changing the resistance of the detector in proportion to the...
NAVAIR Portable Source Initiative (NPSI) Standard for Reusable Source Dataset Metadata (RSDM) V2.4
2012-09-26
defining a raster file format: <RasterFileFormat> <FormatName>TIFF</FormatName> <Order>BIP</Order> < DataType >8-BIT_UNSIGNED</ DataType ...interleaved by line (BIL); Band interleaved by pixel (BIP). element RasterFileFormatType/ DataType diagram type restriction of xsd:string facets
Graph-based layout analysis for PDF documents
NASA Astrophysics Data System (ADS)
Xu, Canhui; Tang, Zhi; Tao, Xin; Li, Yun; Shi, Cao
2013-03-01
To increase the flexibility and enrich the reading experience of e-book on small portable screens, a graph based method is proposed to perform layout analysis on Portable Document Format (PDF) documents. Digital born document has its inherent advantages like representing texts and fractional images in explicit form, which can be straightforwardly exploited. To integrate traditional image-based document analysis and the inherent meta-data provided by PDF parser, the page primitives including text, image and path elements are processed to produce text and non text layer for respective analysis. Graph-based method is developed in superpixel representation level, and page text elements corresponding to vertices are used to construct an undirected graph. Euclidean distance between adjacent vertices is applied in a top-down manner to cut the graph tree formed by Kruskal's algorithm. And edge orientation is then used in a bottom-up manner to extract text lines from each sub tree. On the other hand, non-textual objects are segmented by connected component analysis. For each segmented text and non-text composite, a 13-dimensional feature vector is extracted for labelling purpose. The experimental results on selected pages from PDF books are presented.
Luo, Mingzhang; Li, Weijie; Wang, Bo; Fu, Qingqing; Song, Gangbing
2017-02-23
Rock bolts, as a type of reinforcing element, are widely adopted in underground excavations and civil engineering structures. Given the importance of rock bolts, the research outlined in this paper attempts to develop a portable non-destructive evaluation method for assessing the length of installed rock bolts for inspection purposes. Traditionally, piezoelectric elements or hammer impacts were used to perform non-destructive evaluation of rock bolts. However, such methods suffered from many major issues, such as the weak energy generated and the requirement for permanent installation for piezoelectric elements, and the inconsistency of wave generation for hammer impact. In this paper, we proposed a portable device for the non-destructive evaluation of rock bolt conditions based on a giant magnetostrictive (GMS) actuator. The GMS actuator generates enough energy to ensure multiple reflections of the stress waves along the rock bolt and a lead zirconate titantate (PZT) sensor is used to detect the reflected waves. A new integrated procedure that involves correlation analysis, wavelet denoising, and Hilbert transform was proposed to process the multiple reflection signals to determine the length of an installed rock bolt. The experimental results from a lab test and field tests showed that, by analyzing the instant phase of the periodic reflections of the stress wave generated by the GMS transducer, the length of an embedded rock bolt can be accurately determined.
Luo, Mingzhang; Li, Weijie; Wang, Bo; Fu, Qingqing; Song, Gangbing
2017-01-01
Rock bolts, as a type of reinforcing element, are widely adopted in underground excavations and civil engineering structures. Given the importance of rock bolts, the research outlined in this paper attempts to develop a portable non-destructive evaluation method for assessing the length of installed rock bolts for inspection purposes. Traditionally, piezoelectric elements or hammer impacts were used to perform non-destructive evaluation of rock bolts. However, such methods suffered from many major issues, such as the weak energy generated and the requirement for permanent installation for piezoelectric elements, and the inconsistency of wave generation for hammer impact. In this paper, we proposed a portable device for the non-destructive evaluation of rock bolt conditions based on a giant magnetostrictive (GMS) actuator. The GMS actuator generates enough energy to ensure multiple reflections of the stress waves along the rock bolt and a lead zirconate titantate (PZT) sensor is used to detect the reflected waves. A new integrated procedure that involves correlation analysis, wavelet denoising, and Hilbert transform was proposed to process the multiple reflection signals to determine the length of an installed rock bolt. The experimental results from a lab test and field tests showed that, by analyzing the instant phase of the periodic reflections of the stress wave generated by the GMS transducer, the length of an embedded rock bolt can be accurately determined. PMID:28241503
NASA Astrophysics Data System (ADS)
Pla, D.; Sánchez-González, A.; Garbayo, I.; Salleras, M.; Morata, A.; Tarancón, A.
2015-10-01
The inherent limited capacity of current battery technology is not sufficient for covering the increasing power requirements of widely extended portable devices. Among other promising alternatives, recent advances in the field of micro-Solid Oxide Fuel Cells (μ-SOFCs) converted this disruptive technology into a serious candidate to power next generations of portable devices. However, the implementation of single cells in real devices, i.e. μ-SOFC stacks coupled to the required balance-of-plant elements like fuel reformers or post combustors, still remains unexplored. This work aims addressing this system-level research by proposing a new compact design of a vertically stacked device fuelled with ethanol. The feasibility and design optimization for achieving a thermally self-sustained regime and a rapid and low-power consuming start-up is studied by finite volume analysis. An optimal thermal insulation strategy is defined to maintain the steady-state operation temperature of the μ-SOFC at 973 K and an external temperature lower than 323 K. A hybrid start-up procedure, based on heaters embedded in the μ-SOFCs and heat released by chemical reactions in the post-combustion unit, is analyzed allowing start-up times below 1 min and energy consumption under 500 J. These results clearly demonstrate the feasibility of high temperature μ-SOFC power systems fuelled with hydrocarbons for portable applications, therefore, anticipating a new family of mobile and uninterrupted power generators.
NASA Astrophysics Data System (ADS)
Assael, Marc J.; Antoniadis, Konstantinos D.; Metaxa, Ifigeneia N.; Mylona, Sofia K.; Assael, John-Alexander M.; Wu, Jiangtao; Hu, Miaomiao
2015-11-01
A new portable absolute Transient Hot-Wire instrument for measuring the thermal conductivity of solids over a range of 0.2 { W}{\\cdot }m^{-1}{\\cdot }{K}^{-1} to 4 { W}{\\cdot }m^{-1}{\\cdot }{K}^{-1} is presented. The new instrument is characterized by three novelties: (a) an innovative two-wires sensor which provides robustness and portability, while at the same time employs a soft silicone layer to eliminate the effect of the contact resistance between the wires and the sample, (b) a newly designed compact portable printed electronic board employing an FPGA architecture CPU to the control output voltage and data processing—the new board replaces the traditional, large in size Wheatstone-type bridge system required to perform the experimental measurements, and (c) a cutting-edge software suite, developed for the mesh describing the structure of the sensor, and utilizing the Finite Elements Method to model the heat flow. The estimation of thermal conductivity is modeled as a minimization problem and is solved using Bayesian Optimization. Our revolutionizing proposed methodology exhibits radical speedups of up to × 120, compared to previous approaches, and considerably reduces the number of simulations performed, achieving convergence only in a few minutes. The new instrument was successfully employed to measure, at room temperature, the thermal conductivity of two thermal conductivity reference materials, Pyroceram 9606 and Pyrex 7740, and two possible candidate glassy solids, PMMA and BK7, with an absolute low uncertainty of 2 %.
Development of the International Space Station Fine Water Mist Portable Fire Extinguisher
NASA Technical Reports Server (NTRS)
Rodriquez, Branelle; Young, GIna
2013-01-01
The National Aeronautics and Space Administration (NASA) is developing a Fine Water Mist (FWM) Portable Fire Extinguisher (PFE) for use on the International Space Station (ISS). The ISS presently uses two different types of fire extinguishers: a water foam extinguisher in the Russian Segments, and a carbon dioxide extinguisher in the United States Orbital Segments, which include Columbus and Kibo pressurized elements. Currently, there are operational and compatibility concerns with the emergency breathing equipment and the carbon dioxide extinguisher. ISS emergency response breathing equipment does not filter carbon dioxide; therefore, crew members are required to have an oxygen supply present during a fire event since the carbon dioxide PFE creates an unsafe breathing environment. The ISS program recommended a nontoxic fire extinguisher to mitigate this operational risk. The FWM PFE can extinguish a fire without creating a hazardous breathing environment for crewmembers. This paper will discuss the unique functional and performance requirements that have been levied on the FWM PFE, identify unique microgravity design considerations for liquid and gas systems, and discuss the NASA ISS specific fire standards that were developed to establish an acceptable portable fire extinguisher s performance.
Martínez-Arkarazo, I; Sarmiento, A; Maguregui, M; Castro, K; Madariaga, J M
2010-08-01
Any restoration performed on cultural heritage artworks must guarantee a low impact on the treated surfaces. Although completely risk-free methods do not exist, the use of tailor-made procedures and the continuous monitoring by portable instrumentation is surely one of the best approaches to conduct a modern restoration process. In this work, a portable Raman monitoring, combined sometimes with spectroscopic techniques providing the elemental composition, is the key analysis technique in the three-step restoration protocol proposed: (a) in situ analysis of the surface to be treated (original composition and degradation products/pollutants) and the cleaning agents used as extractants, (b) the thermodynamic study of the species involved in the treatment in order to design a suitable restoration method and (c) application and monitoring of the treatment. Two cleaning operations based on new technologies were studied and applied to two artworks on mineral supports: a wall painting affected by nitrate impact, and a black crusted stone (chalk) altarpiece. Raman bands of nitrate and gypsum, respectively, decreased after the step-by-step operations in each case, which helped restorers to decide when the treatment was concluded, thus avoiding any further damage to the treated surface of the artworks.
Jia, Xiaofang; Dong, Shaojun; Wang, Erkang
2016-02-15
Electrochemical biosensors have played active roles at the forefront of bioanalysis because they have the potential to achieve sensitive, specific and low-cost detection of biomolecules and many others. Engineering the electrochemical sensing interface with functional nanomaterials leads to novel electrochemical biosensors with improved performances in terms of sensitivity, selectivity, stability and simplicity. Functional nanomaterials possess good conductivity, catalytic activity, biocompatibility and high surface area. Coupled with bio-recognition elements, these features can amplify signal transduction and biorecognition events, resulting in highly sensitive biosensing. Additionally, microfluidic electrochemical biosensors have attracted considerable attention on account of their miniature, portable and low-cost systems as well as high fabrication throughput and ease of scaleup. For example, electrochemical enzymetic biosensors and aptamer biosensors (aptasensors) based on the integrated microchip can be used for portable point-of-care diagnostics and environmental monitoring. This review is a summary of our recent progress in the field of electrochemical biosensors, including aptasensors, cytosensors, enzymatic biosensors and self-powered biosensors based on biofuel cells. We presented the advantages that functional nanomaterials and microfluidic chip technology bring to the electrochemical biosensors, together with future prospects and possible challenges. Copyright © 2015 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Díaz-Michelena, M.; de Frutos, J.; Ordóñez, A. A.; Rivero, M. A.; Mesa, J. L.; González, L.; Lavín, C.; Aroca, C.; Sanz, M.; Maicas, M.; Prieto, J. L.; Cobos, P.; Pérez, M.; Kilian, R.; Baeza, O.; Langlais, B.; Thébault, E.; Grösser, J.; Pappusch, M.
2017-09-01
In space instrumentation, there is currently no instrument dedicated to susceptibly or complete magnetization measurements of rocks. Magnetic field instrument suites are generally vector (or scalar) magnetometers, which locally measure the magnetic field. When mounted on board rovers, the electromagnetic perturbations associated with motors and other elements make it difficult to reap the benefits from the inclusion of such instruments. However, magnetic characterization is essential to understand key aspects of the present and past history of planetary objects. The work presented here overcomes the limitations currently existing in space instrumentation by developing a new portable and compact multi-sensor instrument for ground breaking high-resolution magnetic characterization of planetary surfaces and sub-surfaces. This new technology introduces for the first time magnetic susceptometry (real and imaginary parts) as a complement to existing compact vector magnetometers for planetary exploration. This work aims to solve the limitations currently existing in space instrumentation by means of providing a new portable and compact multi-sensor instrument for use in space, science and planetary exploration to solve some of the open questions on the crustal and more generally planetary evolution within the Solar System.
Scalable Trust of Next-Generation Management (STRONGMAN)
2004-10-01
remote logins might be policy controlled to allow only strongly encrypted IPSec tunnels to log in remotely, to access selected files, etc. The...and Angelos D. Keromytis. Drop-in Security for Distributed and Portable Computing Elements. Emerald Journal of Internet Research. Electronic...Security and Privacy, pp. 17-31, May 1999. [2] S. M. Bellovin. Distributed Firewalls. ; login : magazine, special issue on security, November 1999. [3] M
Portable Chemical Agent Detection System: Differential Reflectometer and Light Scattering Approaches
2005-02-15
possible to conduct elemental analysis on modified capillaries because of the polymer coating. Instead, measurements of electroosmotic flow were used...design There are several essential requirements for a sensitive chemiluminescence cell (Figure 1); good reagent/analyte mixing for maximum photon yield...Cutaway of Chemiluminescence cell the cooled pint housing. In our design, the concentric inlets will increase photon collection due to better mixing of
Frade, A; Vilar, D
1991-05-01
The article on sex education in Portugal covers background, the educational system, the clashes of the 1960's over sex education, the Committee for the Study of Sexuality and Education (CSSE), the policies, politics and social movements during the period 1974 - 1984, the discussions in Parliament, the 1988 Reform of the Educational System, the Family Planning Association (FPA) and sex education, and the future role of the FPA. It was not until the institution of the multiparity parliamentary system in 1974 that discussing social and political changes was possible, culminating in 1984 with new legislation on abortion, family planning, and sex education. School reform came in 1987/8 with the Ministry of Education primarily responsible for curricula. The 1960's brought with it the influence of the Catholic Church. Change came in the form of progressivism among Catholics who replaced dogma with dialogue and listening. Sex education was considered as preparation for marriage, but masturbation, contraception, and prostitution were also discussed. In addition, the founder of FPA chaired the CSSE in 1971 and opened up debate on sex issues and drafted a bill to establish co-education in Portuguese schools. The revolution of 1974 brought an end to censorship and brought forth a policy of developing family planning. Changed in the Family Code gave women greater equality. UNFPA supported teacher training in non-sexist education. With human reproduction included in the natural sciences, there was still no school sex education policy and contraception was only sometimes represented in the biology curriculum. The focus of FPA was on contraception and abortion. Finally in the 1980's, the first sex education programs were developed for out-of-school youth. Even though in the 1970's there were leftists groups promoting sex education, it took leftist parliamentary power to get legislation on sex education in the schools adopted. The Ministry of Education however was pressured by the Catholic Church. As in 1973, committees were formed but no action was taken. Sex education activity increased nonetheless - the first FPA document on school education prepared. In 1986 Personal and Social Education was approved by parliament providing an alternative (due to the Catholic Church) to Religious Education, but even with FPA support documents, the implementation did not begin until the end of 1990. In brief the FPA's emphasis was on the body, sexuality, sex and interpersonal relationships, and sexual reproduction. The role of FPA continues at the grass roots level in stimulating discussion; cooperating with schools, students and parents; and acting as a resource center.
Han, Jian; Liu, Juan; Yao, Xincheng; Wang, Yongtian
2015-02-09
A compact waveguide display system integrating freeform elements and volume holograms is presented here for the first time. The use of freeform elements can broaden the field of view, which limits the applications of a holographic waveguide. An optimized system can achieve a diagonal field of view of 45° when the thickness of the waveguide planar is 3mm. Freeform-elements in-coupler and the volume holograms out-coupler were designed in detail in our study, and the influence of grating configurations on diffraction efficiency was analyzed thoroughly. The off-axis aberrations were well compensated by the in-coupler and the diffraction efficiency of the optimized waveguide display system could reach 87.57%. With integrated design, stability and reliability of this monochromatic display system were achieved and the alignment of the system was easily controlled by the record of the volume holograms, which makes mass production possible.
Han, Jian; Liu, Juan; Yao, Xincheng; Wang, Yongtian
2015-01-01
A compact waveguide display system integrating freeform elements and volume holograms is presented here for the first time. The use of freeform elements can broaden the field of view, which limits the applications of a holographic waveguide. An optimized system can achieve a diagonal field of view of 45° when the thickness of the waveguide planar is 3mm. Freeform-elements in-coupler and the volume holograms out-coupler were designed in detail in our study, and the influence of grating configurations on diffraction efficiency was analyzed thoroughly. The off-axis aberrations were well compensated by the in-coupler and the diffraction efficiency of the optimized waveguide display system could reach 87.57%. With integrated design, stability and reliability of this monochromatic display system were achieved and the alignment of the system was easily controlled by the record of the volume holograms, which makes mass production possible. PMID:25836207
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hoekstra, Robert J.; Hammond, Simon David; Richards, David
2017-09-01
This milestone is a tri-lab deliverable supporting ongoing Co-Design efforts impacting applications in the Integrated Codes (IC) program element Advanced Technology Development and Mitigation (ATDM) program element. In FY14, the trilabs looked at porting proxy application to technologies of interest for ATS procurements. In FY15, a milestone was completed evaluating proxy applications in multiple programming models and in FY16, a milestone was completed focusing on the migration of lessons learned back into production code development. This year, the co-design milestone focuses on extracting the knowledge gained and/or code revisions back into production applications.
A Portable Impedance Immunosensing System for Rapid Detection of Salmonella Typhimurium
Wen, Tao; Wang, Ronghui; Sotero, America; Li, Yanbin
2017-01-01
Salmonella Typhimurium is one of the most dangerous foodborne pathogens and poses a significant threat to human health. The objective of this study was to develop a portable impedance immunosensing system for rapid and sensitive detection of S. Typhimurium in poultry. The developed portable impedance immunosensing system consisted of a gold interdigitated array microelectrode (IDAM), a signal acquisitive interface and a laptop computer with LabVIEW software. The IDAM was first functionalized with 16-Mercaptohexadecanoic acid, and streptavidin was immobilized onto the electrode surface through covalent bonding. Then, biotin-labelled S. Typhimurium-antibody was immobilized onto the IDAM surface. Samples were dropped on the surface of the IDAM and the S. Typhimurium cells in the samples were captured by the antibody on the IDAM. This resulted in impedance changes that were measured and displayed with the LabVIEW software. An equivalent circuit of the immunosensor demonstrated that the largest change in impedance was due to the electron-transfer resistance. The equivalent circuit showed an increase of 35% for the electron-transfer resistance value compared to the negative control. The calibration result indicated that the portable impedance immunosensing system could be used to measure the standard impedance elements, and it had a maximum error of measurement of approximately 13%. For pure culture detection, the system had a linear relationship between the impedance change and the logarithmic value of S. Typhimurium cells ranging from 76 to 7.6 × 106 CFU (colony-forming unit) (50 μL)−1. The immunosensor also had a correlation coefficient of 0.98, and a high specificity for detection of S. Typhimurium cells with a limit of detection (LOD) of 102 CFU (50 μL)−1. The detection time from the moment a sample was introduced to the display of the results was 1 h. To conclude, the portable impedance immunosensing system for detection of S. Typhimurium achieved an LOD that is comparable with commercial electrochemical impedance instruments. The developed impedance immunosensor has advantages in portability, low cost, rapid detection and label-free features showing a great potential for in-field detection of foodborne pathogens. PMID:28846643
A Portable Impedance Immunosensing System for Rapid Detection of Salmonella Typhimurium.
Wen, Tao; Wang, Ronghui; Sotero, America; Li, Yanbin
2017-08-28
Salmonella Typhimurium is one of the most dangerous foodborne pathogens and poses a significant threat to human health. The objective of this study was to develop a portable impedance immunosensing system for rapid and sensitive detection of S . Typhimurium in poultry. The developed portable impedance immunosensing system consisted of a gold interdigitated array microelectrode (IDAM), a signal acquisitive interface and a laptop computer with LabVIEW software. The IDAM was first functionalized with 16-Mercaptohexadecanoic acid, and streptavidin was immobilized onto the electrode surface through covalent bonding. Then, biotin-labelled S . Typhimurium -antibody was immobilized onto the IDAM surface. Samples were dropped on the surface of the IDAM and the S . Typhimurium cells in the samples were captured by the antibody on the IDAM. This resulted in impedance changes that were measured and displayed with the LabVIEW software. An equivalent circuit of the immunosensor demonstrated that the largest change in impedance was due to the electron-transfer resistance. The equivalent circuit showed an increase of 35% for the electron-transfer resistance value compared to the negative control. The calibration result indicated that the portable impedance immunosensing system could be used to measure the standard impedance elements, and it had a maximum error of measurement of approximately 13%. For pure culture detection, the system had a linear relationship between the impedance change and the logarithmic value of S . Typhimurium cells ranging from 76 to 7.6 × 10⁶ CFU (colony-forming unit) (50 μL) -1 . The immunosensor also had a correlation coefficient of 0.98, and a high specificity for detection of S . Typhimurium cells with a limit of detection (LOD) of 10² CFU (50 μL) -1 . The detection time from the moment a sample was introduced to the display of the results was 1 h. To conclude, the portable impedance immunosensing system for detection of S . Typhimurium achieved an LOD that is comparable with commercial electrochemical impedance instruments. The developed impedance immunosensor has advantages in portability, low cost, rapid detection and label-free features showing a great potential for in-field detection of foodborne pathogens.
Temperature programmable microfabricated gas chromatography column
Manginell, Ronald P.; Frye-Mason, Gregory C.
2003-12-23
A temperature programmable microfabricated gas chromatography column enables more efficient chemical separation of chemical analytes in a gas mixture by the integration of a resistive heating element and temperature sensing on the microfabricated column. Additionally, means are provided to thermally isolate the heated column from their surroundings. The small heat capacity and thermal isolation of the microfabricated column improves the thermal time response and power consumption, both important factors for portable microanalytical systems.
NASA Astrophysics Data System (ADS)
Rehse, Steven; Trojand, Daniel; Putnam, Russell; Gillies, Derek; Woodman, Ryan; Sheikh, Khadija; Daabous, Andrew
2013-05-01
There is a well-known and urgent need in the fields of medicine, environmental health and safety, food-processing, and defense/security to develop new 21st Century technologies for the rapid and sensitive identification of bacterial pathogens. In only the last five years, the use of a real-time elemental (atomic) analysis performed with laser-induced breakdown spectroscopy (LIBS) has made tremendous progress in becoming a viable technology for rapid bacterial pathogen detection and identification. In this talk we will show how this laser-based optical emission spectroscopic technique is able to sensitively assay the elemental composition of bacterial cells in situ. We will also present the latest achievements of our lab to fully develop LIBS-based bacterial sensing including simulation of a rapid urinary tract infection diagnosis and investigation of a variety of autonomous multivariate analysis algorithms. Lastly, we will show how this technology is now ready to be transitioned from the laboratory to field-portable and potentially man-portable instrumentation. The introduction of such a technology into popular use could very well transform the field of bacterial biosensing - a market valued at approximately 10 billion/year world-wide. Funding for this project was provided in part by a Natural Sciences and Engineering Research Council of Canada Discovery Grant.
NASA Astrophysics Data System (ADS)
Elznicova, Jitka; Sikora, Martin; Slaba, Eva; Popelka, Jan; Hosek, Michal; Matys Grygar, Tomas
2015-04-01
The Ploucnice River (the Czech Republic) was contaminated by uranium mining in the areas of Hamr na Jezere and Straz pod Ralskem mainly in 1971-1987. The pollutants are now deposited all over the floodplain of the river. In 2005 the aerial mapping of radioactive pollution in the floodplain of the Ploucnice River was performed at a height of 80 m above the ground in grid 250 x 250 m. That survey showed uneven, highly localised deposition of gamma-emitting nuclides along nearly the entire reach of the Ploucnice River. We studied several of those radioactivity hotspots 10-25 km downstream from the uranium mining area in aim to understand the reasons for that heterogeneity. The contamination of the floodplain was analysed mainly by two portable (handheld) instruments. The gamma-spectrometer DISA 400A was used for measuring the total surface gamma activity (main target nuclide was Ra-226). Very effective was also the use of portable X-ray fluorescence spectrometer (XRF) Olympus Innov-X (DELTA Premium), which provides fast analysis of more than 30 elements, such as pollutants (Ba, Ni, Pb, U and Zn) and grain-size sensitive lithogenic elements (Al, Si, Zr, Rb). Besides pollution mapping, XRF also allows for mapping sediment lithology using Al/Si or Rb/Zr element ratios (both proportional to the percentage of fine fraction). The field gamma spectrometry and XRF was performed with points 2-30 meters spaced, which revealed that hotspots according to low resolution (250 m) aerial mapping is composed of one or several strongly polluted areas with sizes up to several tens of metres. Similarly heterogeneous was also the distribution of sediment lithology in the floodplain. In some cases, micromorphology of the floodplain, formed mainly by the past meander abandonments and channel shifts was responsible for the heterogeneity of the pollution. To understand the floodplain development we used old maps and aerial photographs. The Czech Republic has an extensive archive of historical aerial photos from 1938 and then from 1953 to the present with 5 or 10 years intervals. The maximal contamination was found in places where there was a meander cuts shortly after a flood (>Q50) in1981. Additionally we used digital elevation model (DEM), created from a laser scanning (LIDAR) dataset DMR 5G obtained in 2010 with nominal altitudinal precision of 0.18 m in open terrain and 0.3 in forested terrain. Our study demonstrated that very detailed, high-resolution analysis of pollution distribution in the floodplain, achievable by portable analytical instruments and interpreted on the base of micro-geomorphology analysis, help to better understand the sedimentation patterns and sediment reworking in fluvial systems.
Evaluation of modified portable digital camera for screening of diabetic retinopathy.
Chalam, Kakarla V; Brar, Vikram S; Keshavamurthy, Ravi
2009-01-01
To describe a portable wide-field noncontact digital camera for posterior segment photography. The digital camera has a compound lens consisting of two optical elements (a 90-dpt and a 20-dpt lens) attached to a 7.2-megapixel camera. White-light-emitting diodes are used to illuminate the fundus and reduce source reflection. The camera settings are set to candlelight mode, the optic zoom standardized to x2.4 and the focus is manually set to 3.0 m. The new technique provides quality wide-angle digital images of the retina (60 degrees ) in patients with dilated pupils, at a fraction of the cost of established digital fundus photography. The modified digital camera is a useful alternative technique to acquire fundus images and provides a tool for screening posterior segment conditions, including diabetic retinopathy in a variety of clinical settings.
Portable XRF and principal component analysis for bill characterization in forensic science.
Appoloni, C R; Melquiades, F L
2014-02-01
Several modern techniques have been applied to prevent counterfeiting of money bills. The objective of this study was to demonstrate the potential of Portable X-ray Fluorescence (PXRF) technique and the multivariate analysis method of Principal Component Analysis (PCA) for classification of bills in order to use it in forensic science. Bills of Dollar, Euro and Real (Brazilian currency) were measured directly at different colored regions, without any previous preparation. Spectra interpretation allowed the identification of Ca, Ti, Fe, Cu, Sr, Y, Zr and Pb. PCA analysis separated the bills in three groups and subgroups among Brazilian currency. In conclusion, the samples were classified according to its origin identifying the elements responsible for differentiation and basic pigment composition. PXRF allied to multivariate discriminate methods is a promising technique for rapid and no destructive identification of false bills in forensic science. Copyright © 2013 Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Paul, Heather L.; Sompayrac, Robert; Conger, Bruce; Chamberlain, Mateo
2009-01-01
As development of the Constellation Space Suit Element progresses, designing the most effective and efficient life support systems is critical. The baseline schematic analysis for the Portable Life Support System (PLSS) indicates that the ventilation loop will need some method of heat exchange and humidification prior to entering the helmet. A trade study was initiated to identify the challenges associated with conditioning the spacesuit breathing gas stream for temperature and water vapor control, to survey technological literature and resources on heat exchanger and humidifiers to provide solutions to the problems of conditioning the spacesuit breathing gas stream, and to propose potential candidate technologies to perform the heat exchanger and humidifier functions. This paper summarizes the results of this trade study and also describes the conceptual designs that NASA developed to address these issues.
NASA Technical Reports Server (NTRS)
Paul, Heather L.; Conger, Bruce; Sompyrac, Robert; Chamberlain, Mateo
2008-01-01
As development of the Constellation Space Suit Element progresses, designing the most effective and efficient life support systems is critical. The baseline schematic analysis for the Portable Life Support System (PLSS) indicates that the ventilation loop will need some method of heat exchange and humidification prior to entering the helmet. A trade study was initiated to identify the challenges associated with conditioning the spacesuit breathing gas stream for temperature and water vapor control, to survey technological literature and resources on heat exchanger and humidifiers to provide solutions to the problems of conditioning the spacesuit breathing gas stream, and to propose potential candidate technologies to perform the heat exchanger and humidifier functions. This paper summarizes the results of this trade study and also describes the conceptual designs that NASA developed to address these issues.
Tykot, Robert H
2016-01-01
Elemental analysis is a fundamental method of analysis on archaeological materials to address their overall composition or identify the source of their geological components, yet having access to instrumentation, its often destructive nature, and the time and cost of analyses have limited the number and/or size of archaeological artifacts tested. The development of portable X-ray fluorescence (pXRF) instruments over the past decade, however, has allowed nondestructive analyses to be conducted in museums around the world, on virtually any size artifact, producing data for up to several hundred samples per day. Major issues have been raised, however, about the sensitivity, precision, and accuracy of these devices, and the limitation of performing surface analysis on potentially heterogeneous objects. The advantages and limitations of pXRF are discussed here regarding archaeological studies of obsidian, ceramics, metals, bone, and painted materials. © The Author(s) 2015.
Kaigala, Govind V; Hoang, Viet N; Backhouse, Christopher J
2008-07-01
Microvalves are key in realizing portable miniaturized diagnostic platforms. We present a scalable microvalve that integrates well with standard lab on a chip (LOC) implementations, yet which requires essentially no external infrastructure for its operation. This electrically controlled, phase-change microvalve is used to integrate genetic amplification and analysis via capillary electrophoresis--the basis of many diagnostics. The microvalve is actuated using a polymer (polyethylene glycol, PEG) that exhibits a large volumetric change between its solid and liquid phases. Both the phase change of the PEG and the genetic amplification via polymerase chain reaction (PCR) are thermally controlled using thin film resistive elements that are patterned using standard microfabrication methods. By contrast with many other valve technologies, these microvalves and their control interface scale down in size readily. The novelty here lies in the use of fully integrated microvalves that require only electrical connections to realize a portable and inexpensive genetic analysis platform.
Wireless Data Acquisition of Transient Signals for Mobile Spectrometry Applications.
Trzcinski, Peter; Weagant, Scott; Karanassios, Vassili
2016-05-01
Wireless data acquisition using smartphones or handhelds offers increased mobility, it provides reduced size and weight, it has low electrical power requirements, and (in some cases) it has an ability to access the internet. Thus, it is well suited for mobile spectrometry applications using miniaturized, field-portable spectrometers, or detectors for chemical analysis in the field (i.e., on-site). There are four main wireless communications standards that can be used for wireless data acquisition, namely ZigBee, Bluetooth, Wi-Fi, and UWB (ultra-wide band). These are briefly reviewed and are evaluated for applicability to data acquisition of transient signals (i.e., time-domain) in the field (i.e., on-site) from a miniaturized, field-portable photomultiplier tube detector and from a photodiode array detector installed in a miniaturized, field-portable fiber optic spectrometer. These are two of the most widely used detectors for optical measurements in the ultraviolet-visible range of the spectrum. A miniaturized, 3D-printed, battery-operated microplasma-on-a-chip was used for generation of transient optical emission signals. Elemental analysis from liquid microsamples, a microplasma, and a handheld or a smartphone will be used as examples. Development and potential applicability of wireless data acquisition of transient optical emission signals for taking part of the lab to the sample types of mobile, field-portable spectrometry applications will be discussed. The examples presented are drawn from past and ongoing work in the authors' laboratory. A handheld or a smartphone were used as the mobile computing devices of choice. © The Author(s) 2016.
A portable microscopy system for fluorescence, polarized, and brightfield imaging
NASA Astrophysics Data System (ADS)
Gordon, Paul; Wattinger, Rolla; Lewis, Cody; Venancio, Vinicius Paula; Mertens-Talcott, Susanne U.; Coté, Gerard
2018-02-01
The use of mobile phones to conduct diagnostic microscopy at the point-of-care presents intriguing possibilities for the advancement of high-quality medical care in remote settings. However, it is challenging to create a single device that can adapt to the ever-varying camera technologies in phones or that can image with the customization that multiple modalities require for applications such as malaria diagnosis. A portable multi-modal microscope system is presented that utilizes a Raspberry Pi to collect and transmit data wirelessly to a myriad of electronic devices for image analysis. The microscopy system is capable of providing to the user correlated brightfield, polarized, and fluorescent images of samples fixed on traditional microscopy slides. The multimodal diagnostic capabilities of the microscope were assessed by measuring parasitemia of Plasmodium falciparum-infected thin blood smears. The device is capable of detecting fluorescently-labeled DNA using FITC excitation (490 nm) and emission (525 nm), the birefringent P. falciparum byproduct hemozoin, and detecting brightfield absorption with a resolution of 0.78 micrometers (element 9-3 of a 1951 Air Force Target). This microscopy system is a novel portable imaging tool that may be a viable candidate for field implementation if challenges of system durability, cost considerations, and full automation can be overcome.
A Z-axis recumbent rotating device for use in parabolic flight
NASA Technical Reports Server (NTRS)
Graybiel, A.; Miller, E. F., II
1976-01-01
A prototype apparatus for exposing persons to rotation about their Z-axis in parabolic flight is described. Although it resembles earth-horizontal axis devices, added features are its strength and portability, and the fiber glass 'couch' with adjustable elements providing support and restraint. Even under ground-based conditions, this device provides unique opportunities for investigations involving not only canalicular and macular mechanoreceptors, but also touch, pressure, and kinesthetic receptor systems.
Mobile Learning Panel (Briefing Slides)
2010-08-12
00-2010 4 . TITLE AND SUBTITLE Mobile Learning Panel 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) 5d. PROJECT...the Air Force and draw information from an enterprise knowledge base. • Self-paced individual training • Mandatory annual training • Classroom...iPhone • Sony Playstation Portable • Sony e-Reader • HTC, Palm, and Android CONTACT Leeescoemobile@conus.army.mil EVENT FACEBOOK Fort Lee
Target contrast considerations in millimeter wave radiometry for airborne navigation
NASA Technical Reports Server (NTRS)
Mayer, A.
1971-01-01
Target signal requirements for aircraft navigation systems that use radiometric receivers which map thermally emitted power radiated by terrain or power radiated by ground-based beacons are discussed. For selected millimeter wavelength bands, microwaves suffer relatively little degradation by absorption or scattering on passage through the atmosphere, despite extreme weather variations. Interest centers on 8-millimeter waves because of component availability, portability (small size), high image resolution, and all-weather capability at this wavelength. The idea of radiometric airborne navigation is introduced. Elements of radiometry, terrain radiation, and atmospheric transmission characteristics are reviewed. Data pertaining to these elements at 8 mm wavelength are collected. Calculation of radiometric contrasts is discussed for some simple models of terrain targets.
Superhydrophobic surfaces generated by one-pot spray-coating of chitosan-based nanoparticles.
Wang, Shuangfei; Sha, Jiulong; Wang, Wei; Qin, Chengrong; Li, Wei; Qin, Caiqin
2018-09-01
Superhydrophobic surfaces have attracted great attention due to their attractive properties. Biopolymer-based low-cost and environmentally-friendly superhydrophobic coatings with easy-to-perform fabrication methods are always desirable. Herein, we report superhydrophobic surfaces using a one-step spray-coating of chitosan-based nanoparticles. The particles were easily prepared by a nanoprecipitation strategy using synthesized organosoluble chitosan stearoyl ester (CSSE). The resulting particles had an average size of 165 ∼ 235 nm depending on the applied concentration. Subsequently, spray-coating of such particles onto silicon wafer generated a surface with a water contact angle of 155 ± 1°. SEM and AFM images exhibited a nano/microscaled roughness appeared on the coated surface. The superhydrophobic surfaces showed a stable superhydrophobic performance even after storage for 15 days, pH stability between pH 1 to pH 11 and thermal stability until a temperature no more than 50 °C. These properties would broaden the application fields of superhydrophobic surfaces as well as the chitosan itself. Copyright © 2018 Elsevier Ltd. All rights reserved.
Two-lattice models of trace element behavior: A response
NASA Astrophysics Data System (ADS)
Ellison, Adam J. G.; Hess, Paul C.
1990-08-01
Two-lattice melt components of Bottinga and Weill (1972), Nielsen and Drake (1979), and Nielsen (1985) are applied to major and trace element partitioning between coexisting immiscible liquids studied by RYERSON and Hess (1978) and Watson (1976). The results show that (1) the set of components most successful in one system is not necessarily portable to another system; (2) solution non-ideality within a sublattice severely limits applicability of two-lattice models; (3) rigorous application of two-lattice melt components may yield effective partition coefficients for major element components with no physical interpretation; and (4) the distinction between network-forming and network-modifying components in the sense of the two-lattice models is not clear cut. The algebraic description of two-lattice models is such that they will most successfully limit the compositional dependence of major and trace element solution behavior when the effective partition coefficient of the component of interest is essentially the same as the bulk partition coefficient of all other components within its sublattice.
Giansanti, Daniele; Morelli, Sandra; Maccioni, Giovanni; Brocco, Monica
2013-10-01
When designing a complete system of daily-telerehabilitation it should be borne in mind that properly designed methodologies should be furnished for patients to execute specific motion tasks and for care givers to assess the relevant parameters. Whether in hospital or at home, the system should feature two basic elements: (a) instrumented and walking aids or supports, (b) equipment for the assessment of parameters. Being gait the focus, the idea was to design, construct and validate - as an alternative to the complex and expensive instruments currently used - a simple, portable kit that may be easily interfaced/integrated with the most common mechanical tools used in motion rehabilitation (instrumented walkways, aids, supports), with feedback to both patient for self-monitoring and trainer/therapist (present or remote) for clinical reporting. The proposed system consists of: one step-counter, three couples of photo-emitter detectors, one central unit for collecting and processing the telemetrically transmitted data; a software interface on a dedicated PC and a network adapter. The system has been successfully validated in a clinical application on two groups of 16 subjects at the 1st and 2nd level of the Tinetti test. The degree of acceptance by subjects and care-givers was high. The system was also successfully compared with an Inertial Measurement Unit, a de facto standard. The portable kit can be used with different rehabilitation tools and different ground rugosity. The advantages are: (a) very low costs when compared with optoelectronic solutions and other portable solutions; (b) very high accuracy, also for subjects with imbalance problems; (c) good compatibility with any rehabilitative tool. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
Biogeological Analysis of Desert Varnish Using Portable Raman Spectrometers.
Malherbe, Cedric; Ingley, Richard; Hutchinson, Ian; Edwards, Howell; Carr, Andrew S; Harris, Liam; Boom, Arnoud
2015-06-01
Desert varnishes are thin, dark mineral coatings found on some rocks in arid or semi-arid environments on Earth. Microorganisms may play an active role in their formation, which takes many hundreds of years. Their mineral matrix may facilitate the preservation of organic matter and is therefore of great relevance to martian exploration. Miniaturized Raman spectrometers (which allow nondestructive analysis of the molecular composition of a specimen) will equip rovers in forthcoming planetary exploration missions. In that context, and for the first time, portable Raman spectrometers operating in the green visible (532 nm as currently baselined for flight) and in the near-infrared (785 nm) were used in this study to investigate the composition (and substrate) of several samples of desert varnish. Rock samples that were suspected (and later confirmed) to be coated with desert varnish were recovered from two sites in the Mojave Desert, USA. The portable spectrometers were operated in flight-representative acquisition modes to identify the key molecular components of the varnish. The results demonstrate that the coatings typically comprise silicate minerals such as quartz, plagioclase feldspars, clays, ferric oxides, and hydroxides and that successful characterization of the samples can be achieved by using flightlike portable spectrometers for both the 532 and 785 nm excitation sources. In the context of searching for spectral signatures and identifying molecules that indicate the presence of extant and/or extinct life, we also report the detection of β-carotene in some of the samples. Analysis complications caused by the presence of rare earth element photoluminescence (which overlaps with and overwhelms the organic Raman signal when a 785 nm laser is employed) are also discussed.
Rugged, portable tungsten coil atomic emission spectrometer.
Gu, Jiyan; Oliveira, Silvana R; Donati, George L; Gomes Neto, José Anchieta; Jones, Bradley T
2011-04-01
Tungsten coil atomic emission spectrometry is an ideal technique for field applications because of its simplicity, low cost, low power requirement, and independence from cooling systems. A new, portable, compact design is reported here. The tungsten coil is extracted from an inexpensive 24 V, 250 W commercial light bulb. The coil is housed in a small, aluminum cell. The emission signal exits from a small aperture in the cell, while the bulk of the blackbody emission from the tungsten coil is blocked. The resulting spectra exhibit extremely low background signals. The atomization cell, a single lens, and a hand-held charge coupled device (CCD) spectrometer are fixed on a 1 × 6 × 30 cm ceramic base. The resulting system is robust and easily transported. A programmable, miniature 400 W solid-state constant current power supply controls the temperature of the coil. Fifteen elements are determined with the system (Ba, Cs, Li, Rb, Cr, Sr, Eu, Yb, Mn, Fe, Cu, Mg, V, Al, and Ga). The precision ranges from 4.3% to 8.4% relative standard deviation for repetitive measurements of the same solution. Detection limits are in the 0.04 to 1500 μg/L range. Accuracy is tested using standard reference materials for polluted water, peach leaves, and tomato leaves. For those elements present above the detection limit, recoveries range from 72% to 147%.
Carr, Ramona; Zhang, Chaosheng; Moles, Norman; Harder, Marie
2008-02-01
Heavy metals in urban soils continue to attract attention because of their potential long-term effects on human health. During a previous investigation of urban soils in Galway City, Ireland, a pollution hotspot of Pb, Cu, Zn and As was identified in the sports ground of South Park in the Claddagh. The sports ground was formerly a rubbish dumping site for both municipal and industrial wastes. In the present study, a portable X-ray fluorescence (PXRF) analyser was used to obtain rapid in-situ elemental analyses of the topsoil (depth: about 5-10 cm) at 200 locations on a 20 x 20-m grid in South Park. Extremely high values of the pollutants were found, with maximum values of Pb, Zn, Cu and As of 10,297, 24,716, 2224 and 744 mg/kg soil, respectively. High values occur particularly where the topsoil cover is thin, whereas lower values were found in areas where imported topsoil covers the polluted substrate. Geographic Information Systems (GIS) techniques were applied to the dataset to create elemental spatial distribution maps, three-dimensional images and interpretive hazard maps of the pollutants in the study area. Immediate action to remediate the contaminated topsoil is recommended to safeguard the health of children who play at the sports ground.
Geochemical prospecting for rare earth elements using termite mound materials
NASA Astrophysics Data System (ADS)
Horiuchi, Yu; Ohno, Tetsuji; Hoshino, Mihoko; Shin, Ki-Cheol; Murakami, Hiroyasu; Tsunematsu, Maiko; Watanabe, Yasushi
2014-12-01
The Blockspruit fluorite prospect, located in North West State of the Republic of South Africa, occurs within an actinolite rock zone that was emplaced into the Kenkelbos-type granite of Proterozoic age. There are a large number of termite mounds in the prospect. For geochemical prospecting for rare earth elements (REEs), in total, 200 samples of termite mound material were collected from actinolite rock and granite zones in the prospect. Geochemical analyses of these termite mound materials were conducted by two methods: portable X-ray fluorescence (XRF) spectrometry and inductively coupled plasma-mass spectrometry (ICP-MS). Comparison of the two methods broadly indicates positive correlations of REEs (La, Ce, Pr, Nd, and Y), in particular Y and La having a strong correlation. As the result of modal abundance analyses, the actinolite rock at surface mainly consists of ferro-actinolite (89.89 wt%) and includes xenotime (0.26 wt%) and monazite (0.21 wt%) grains as REE minerals. Termite mound materials from actinolite rock also contain xenotime (0.27 wt%) and monazite (0.41 wt%) grains. In addition, termite mound materials from the actinolite rock zone have high hematite and Fe silicate contents compared to those from granite zone. These relationships suggest that REE minerals in termite mound materials originate form actinolite rock. Geochemical anomaly maps of Y, La, and Fe concentrations drawn based on the result of the portable XRF analyses show that high concentrations of these elements trend from SW to NE which broadly correspond to occurrences of actinolite body. These results indicate that termite mounds are an effective tool for REE geochemical prospection in the study area for both light REEs and Y, but a more detailed survey is required to establish the distribution of the actinolite rock body.
Simulation of a circular phased array for a portable ultrasonic polar scan
NASA Astrophysics Data System (ADS)
Daemen, Jannes; Kersemans, Mathias; Martens, Arvid; Verboven, Erik; Delrue, Steven; Van Paepegem, Wim; Degrieck, Joris; Van Den Abeele, Koen
2018-04-01
The development of new composite materials, often anisotropic in nature, requires intricate approaches to characterize these materials and to detect internal defects. The Ultrasonic Polar Scan (UPS) is able to achieve both goals. During an UPS experiment, a material spot is insonified at several angles Ψ(θ,ϕ), after which the reflected or transmitted signal is recorded. While excellent results have been obtained using an in-house developed 5-axis scanner, UPS measurements with the current set-up are too lengthy and cumbersome for in-situ industrial application. Therefore, we propose to replace the complex mechanical steering of the transducers by a hemispherical phased array consisting of small PZT elements. This allows to create a compact and portable setup without compromising the current data quality. By successively activating a specific set of elements of the array and choosing appropriate inter-element time delays, the beam can be electronically steered from any angle to a fixed position on the targeted sample. Consequently, UPS reflection measurements can be performed at this position from a wide range of angles in a timeframe of seconds. Additionally, by using apodization windows, it is possible to efficiently reduce the intensity of unwanted side lobes and to create a phase profile which closely resembles that of a bounded plane wave, leading to an easier interpretation of the recorded data. The appropriate time delays and apodization parameters can be found though a multi-objective inverse problem in which both the phase profile and the side lobe reduction are optimized. This approach enables the creation of an effective beam profile to be used during UPS experiments for the characterization and inspection of composite materials. Our simulation approach is a crucial step towards a next-generation UPS device for industrial applications and in-field measurements.
Iles, Irina A; Egnoto, Michael J; Fisher Liu, Brooke; Ackerman, Gary; Roberts, Holly; Smith, Daniel
2017-11-01
After the 9/11 terrorist attacks, the U.S. government initiated several national security technology adoption programs. The American public, however, has been skeptical about these initiatives and adoption of national security technologies has been mandated, rather than voluntary. We propose and test a voluntary behavioral intention formation model for the adoption of one type of new security technology: portable radiation detectors. Portable radiation detectors are an efficient way of detecting radiological and nuclear threats and could potentially prevent loss of life and damage to individuals' health. However, their functioning requires that a critical mass of individuals use them on a daily basis. We combine the explanatory advantages of diffusion of innovation with the predictive power of two volitional behavior frameworks: the theory of reasoned action and the health belief model. A large sample survey (N = 1,482) investigated the influence of factors identified in previous diffusion of innovation research on portable radiation detector adoption intention. Results indicated that nonfinancial incentives, as opposed to financial incentives, should be emphasized in persuasive communications aimed at fostering adoption. The research provides a new integration of diffusion of innovation elements with determinants of volitional behavior from persuasion literature, and offers recommendations on effective communication about new security technologies to motivate public adoption and enhance national safety. © 2017 Society for Risk Analysis.
NASA Astrophysics Data System (ADS)
Maiwald, M.; Müller, A.; Sumpf, B.
2017-02-01
In-situ shifted excitation Raman difference spectroscopy (SERDS) experiments are presented using a portable sensor system. Key elements of this system are an in-house developed handheld probe with an implemented dual-wavelength diode laser at 785 nm. An optical power of 120 mW is achieved ex probe. Raman experiments are carried out in the laboratory for qualification using polystyrene as test sample. Here, a shot-noise limited signal-to-noise ratio (SNR) of 120 is achieved. Stability tests were performed and show a stable position of the Raman line under study within 0.1 cm-1 and a stable Raman intensity better +/- 2% mainly limited by shot noise interference. SERDS experiments are carried out in an apple orchard for demonstration. Green apple leafs are used as test samples. The Raman spectra show huge background interferences by fluorescence and ambient daylight which almost obscure Raman signals from green leafs. The selected excitation power is 50 mW and the exposure time is 0.2 s to avoid detector saturation. SERDS efficiently separates the Raman signals from fluorescence and daylight contributions and generates an 11-fold improvement of the signal-to-background noise with respect to the measured Raman signals. The results demonstrate the capability of the portable SERDS system and enable rapid in-situ and undisturbed Raman investigations under daylight conditions.
NASA Astrophysics Data System (ADS)
Shaked, Natan T.; Girshovitz, Pinhas; Frenklach, Irena
2014-06-01
We present our recent advances in the development of compact, highly portable and inexpensive wide-field interferometric modules. By a smart design of the interferometric system, including the usage of low-coherence illumination sources and common-path off-axis geometry of the interferometers, spatial and temporal noise levels of the resulting quantitative thickness profile can be sub-nanometric, while processing the phase profile in real time. In addition, due to novel experimentally-implemented multiplexing methods, we can capture low-coherence off-axis interferograms with significantly extended field of view and in faster acquisition rates. Using these techniques, we quantitatively imaged rapid dynamics of live biological cells including sperm cells and unicellular microorganisms. Then, we demonstrated dynamic profiling during lithography processes of microscopic elements, with thicknesses that may vary from several nanometers to hundreds of microns. Finally, we present new algorithms for fast reconstruction (including digital phase unwrapping) of off-axis interferograms, which allow real-time processing in more than video rate on regular single-core computers.
NASA Astrophysics Data System (ADS)
Varady, M. J.; McLeod, L.; Meacham, J. M.; Degertekin, F. L.; Fedorov, A. G.
2007-09-01
Portable fuel cells are an enabling technology for high efficiency and ultra-high density distributed power generation, which is essential for many terrestrial and aerospace applications. A key element of fuel cell power sources is the fuel processor, which should have the capability to efficiently reform liquid fuels and produce high purity hydrogen that is consumed by the fuel cells. To this end, we are reporting on the development of two novel MEMS hydrogen generators with improved functionality achieved through an innovative process organization and system integration approach that exploits the advantages of transport and catalysis on the micro/nano scale. One fuel processor design utilizes transient, reverse-flow operation of an autothermal MEMS microreactor with an intimately integrated, micromachined ultrasonic fuel atomizer and a Pd/Ag membrane for in situ hydrogen separation from the product stream. The other design features a simpler, more compact planar structure with the atomized fuel ejected directly onto the catalyst layer, which is coupled to an integrated hydrogen selective membrane.
Augmenting your own reality: student authoring of science-based augmented reality games.
Klopfer, Eric; Sheldon, Josh
2010-01-01
Augmented Reality (AR) simulations superimpose a virtual overlay of data and interactions onto a real-world context. The simulation engine at the heart of this technology is built to afford elements of game play that support explorations and learning in students' natural context--their own community and surroundings. In one of the more recent games, TimeLab 2100, players role-play citizens of the early 22nd century when global climate change is out of control. Through AR, they see their community as it might be nearly one hundred years in the future. TimeLab and other similar AR games balance location specificity and portability--they are games that are tied to a location and games that are movable from place to place. Focusing students on developing their own AR games provides the best of both virtual and physical worlds: a more portable solution that deeply connects young people to their own surroundings. A series of initiatives has focused on technical and pedagogical solutions to supporting students authoring their own games.
Witinski, Mark F; Blanchard, Romain; Pfluegl, Christian; Diehl, Laurent; Li, Biao; Krishnamurthy, Kalyani; Pein, Brandt C; Azimi, Masud; Chen, Peili; Ulu, Gokhan; Vander Rhodes, Greg; Howle, Chris R; Lee, Linda; Clewes, Rhea J; Williams, Barry; Vakhshoori, Daryoosh
2018-04-30
This article presents new spectroscopic results in standoff chemical detection that are enabled by monolithic arrays of Distributed Feedback (DFB) Quantum Cascade Lasers (QCLs), with each array element at a slightly different wavelength than its neighbor. The standoff analysis of analyte/substrate pairs requires a laser source with characteristics offered uniquely by a QCL Array. This is particularly true for time-evolving liquid chemical warfare agent (CWA) analysis. In addition to describing the QCL array source developed for long wave infrared coverage, a description of an integrated prototype standoff detection system is provided. Experimental standoff detection results using the man-portable system for droplet examination from 1.3 meters are presented using the CWAs VX and T-mustard as test cases. Finally, we consider three significant challenges to working with droplets and liquid films in standoff spectroscopy: substrate uptake of the analyte, time-dependent droplet spread of the analyte, and variable substrate contributions to retrieved signals.
A standard library for modeling satellite orbits on a microcomputer
NASA Astrophysics Data System (ADS)
Beutel, Kenneth L.
1988-03-01
Introductory students of astrodynamics and the space environment are required to have a fundamental understanding of the kinematic behavior of satellite orbits. This thesis develops a standard library that contains the basic formulas for modeling earth orbiting satellites. This library is used as a basis for implementing a satellite motion simulator that can be used to demonstrate orbital phenomena in the classroom. Surveyed are the equations of orbital elements, coordinate systems and analytic formulas, which are made into a standard method for modeling earth orbiting satellites. The standard library is written in the C programming language and is designed to be highly portable between a variety of computer environments. The simulation draws heavily on the standards established by the library to produce a graphics-based orbit simulation program written for the Apple Macintosh computer. The simulation demonstrates the utility of the standard library functions but, because of its extensive use of the Macintosh user interface, is not portable to other operating systems.
Inertial impaction air sampling device
Dewhurst, Katharine H.
1990-01-01
An inertial impactor to be used in an air sampling device for collection of respirable size particles in ambient air which may include a graphite furnace as the impaction substrate in a small-size, portable, direct analysis structure that gives immediate results and is totally self-contained allowing for remote and/or personal sampling. The graphite furnace collects suspended particles transported through the housing by means of the air flow system, and these particles may be analyzed for elements, quantitatively and qualitatively, by atomic absorption spectrophotometry.
Technology Assessment of Field Portable Instrumentation for Use at Rocky Mountain Arsenal
1988-07-01
masking the original valence state of the element. In cases where the valence state is important to the relative toxicity of the species, ( chromium VI vs... chromium III, or metallic mercury vs. organo alkyl mercury), this is an unfortunate consequence. However, there are some practical reasons as to why...interest or co-precipitate them with an added metal ion with a suitable reagent. If chromium and arsenic were adjusted to a valance of +3, then it should
2012-12-01
identity operation SIMD Single instruction, multiple datastream parallel computing Scala A byte-compiled programming language featuring dynamic type...Specific Languages 5a. CONTRACT NUMBER FA8750-10-1-0191 5b. GRANT NUMBER N/A 5c. PROGRAM ELEMENT NUMBER 61101E 6. AUTHOR(S) Armando Fox 5d...application performance, but usually must rely on efficiency programmers who are experts in explicit parallel programming to achieve it. Since such efficiency
Inertial impaction air sampling device
Dewhurst, K.H.
1987-12-10
An inertial impactor to be used in an air sampling device for collection of respirable size particles in ambient air which may include a graphite furnace as the impaction substrate in a small-size, portable, direct analysis structure that gives immediate results and is totally self-contained allowing for remote and/or personal sampling. The graphite furnace collects suspended particles transported through the housing by means of the air flow system, and these particles may be analyzed for elements, quantitatively and qualitatively, by atomic absorption spectrophotometry. 3 figs.
Portable Android Dari and Pashto Soft Keyboard
2013-08-01
with a collection of information if it does not display a currently valid OMB control number . PLEASE DO NOT RETURN YOUR FORM TO THE ABOVE ADDRESS. 1...Dari and Pashto Soft Keyboard 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) Michael Lee 5d. PROJECT NUMBER R...0006163.9 5e. TASK NUMBER 5f. WORK UNIT NUMBER 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) U.S. Army Research Laboratory ATTN: RDRL
Portable Multi Hydrophone Array for Field and Laboratory Measurements of Odontocete Acoustic Signals
2015-09-30
bottlenose dolphin and a false killer whale as well as other species such as the Risso’s dolphin . We are currently comparing various file types and methods...echolocation abilities of a Risso’s dolphin are currently being reviewed for publication. 3 The hook detection study recordings are being analyzed for basic...element array in order to obtain horizontal and vertical beam patterns of acoustic signals of a false killer whale and a bottlenose dolphin . The data
GEODIS: A Portable Ocean Bottom Very Broadband Seismic Station
NASA Astrophysics Data System (ADS)
KARCZEWSKI, J.; MONTAGNER, J.; BEGUERY, L.; STUTZMANN, E.; ROULT, G.; LOGNONNE, P.; CACHO, S.; KOENIG, J.; SAVARY, J.
2001-12-01
The last ten years have seen the simultaneous development of a global seismic network coordinated through the FDSN (Federation of Digital Seismograph Networks) and of portable broadband seismic arrays. The same approach can be followed for improving our scientific understanding of the Earth processes below oceanic areas. Both components of ocean bottom geophysical networks, will be coordinated by ION (international Ocean Network). They are complementary since they enable to investigate the Earth structure and processes at different spatial and temporal scales. Geophysical Ocean bottom observatories (hereafter referred as GOBO) and portable seismic stations are sharing common technological problems. However, the issues of power supply and real-time data transmission are more crucial for a GOBO than for a portable temporary station. Since 1999, our group is developing a new "portable" geophysical ocean bottom autonomous station, named GEODIS. This station might be a basic element for a GOBO. It relies on the use of adapted VBB sensors issued from space experiments and technology and on improved electronics compared with previous ocean bottom experiments (SISMOBS/OFM 1992; MOISE 1997). The main characteristics of GEODIS are the following: - 3 axes VBB seismic sensors with a classical flat velocity response 360-0.2s. at 2500V/m/s (intrinsic noise level smaller than LNM). - Automatic (under software control) installation, levelling, centring of the 3 component seismic sensors. - 24 bit digitiser recording at 20sps, 3 seismic component and 1 infrasonic sensor. - Recording by a 16 bit converter at 1sps of the sea temperature in the vicinity of the instrument and housekeeping parameters (temperature, inclinations, power,...). - 1 year autonomy by using Lithium batteries. - Storage of data on Flash card and recording on hard disk every day. - Weight of GEODIS: 186kg in air and 110kg in water. - Overall dimensions: 930 x 930 x 440 mm. GEODIS can be easily installed by a small oceanographic vessel. Therefore, GEODIS has been designed in order to be reliable, with a low power consumption, to be financially affordable, to have excellent performances of sensors, to be easy to install and to recover.
NASA Technical Reports Server (NTRS)
Clements, Anna L.
2011-01-01
NASA is developing a Fine Water Mist Portable Fire Extinguisher for use on the International Space Station. The International Space Station presently uses two different types of fire extinguishers: a water foam extinguisher in the Russian Segment, and a carbon dioxide extinguisher in the US Segment and Columbus and Kibo pressurized elements. Changes in emergency breathing equipment make Fine Water Mist operationally preferable. Supplied oxygen breathing systems allow for safe discharge of a carbon dioxide fire extinguisher, without concerns of the crew inhaling unsafe levels of carbon dioxide. But the Portable Breathing Apparatus (PBA) offers no more than 15 minutes of capability, and continued use of hose based supplied oxygen system increases the oxygen content in a fire situation. NASA has developed a filtering respirator cartridge for use in a fire environment. It is qualified to provide up to 90 minutes of capability, and because it is a filtering respirator it does not add oxygen to the environment. The fire response respirator cartridge does not filter carbon dioxide (CO2), so a crew member discharging a CO2 fire extinguisher while wearing this filtering respirator would be at risk of inhaling unsafe levels of CO2. Fine Water Mist extinguishes a fire without creating a large volume of air with reduced oxygen and elevated CO2. From a flight hardware design perspective, the fine water mist fire extinguisher has two major elements: (1) the nozzle and crew interface, and (2) the tank. The nozzle and crew interface has been under development for several years. It has gone through several design iterations, and has been part of more than 400 fire challenge and spray characterizations. The crew and vehicle interface aspects of the design will use the heritage of the CO2 based Portable Fire Extinguisher, to minimize the disruption to the crew and integration impacts to the ISS. The microgravity use environment of the system poses a set of unique design requirements specifically for the tank. The nozzle requirements drive a tank pressure that is 2-5 times higher than any commercially available water mist systems. Microgravity requires deliberate separation of gas and water, facilitated by a bladder, a diaphragm, a piston, or separate tanks. This paper will describe the design details of the tank and the nozzle, and discuss the trade studies that informed the decisions to select the tank and nozzle configuration.
A 24-GHz portable FMCW radar with continuous beam steering phased array (Conference Presentation)
NASA Astrophysics Data System (ADS)
Peng, Zhengyu; Li, Changzhi
2017-05-01
A portable 24-GHz frequency-modulated continuous-wave (FMCW) radar with continuous beam steering phased array is presented. This board-level integrated radar system consists of a phased array antenna, a radar transceiver and a baseband. The phased array used by the receiver is a 4-element linear array. The beam of the phased array can be continuously steered with a range of ±30° on the H-plane through an array of vector controllers. The vector controller is based on the concept of vector sum with binary-phase-shift attenuators. Each vector controller is capable of independently controlling the phase and the amplitude of each element of the linear array. The radar transceiver is based on the six-port technique. A free-running voltage controlled oscillator (VCO) is controlled by an analog "sawtooth" voltage generator to produce frequency-modulated chirp signal. This chirp signal is used as the transmitter signal, as well as the local oscillator (LO) signal to drive the six-port circuit. The transmitter antenna is a single patch antenna. In the baseband, the beat signal of the FMCW radar is detected by the six-port circuit and then processed by a laptop in real time. Experiments have been performed to reveal the capabilities of the proposed radar system for applications including indoor inverse synthetic aperture radar (ISAR) imaging, vital sign detection, and short-range navigation, etc. (This abstract is for the profiles session.)
Gaudiuso, Rosalba; Dell’Aglio, Marcella; De Pascale, Olga; Senesi, Giorgio S.; De Giacomo, Alessandro
2010-01-01
Analytical applications of Laser Induced Breakdown Spectroscopy (LIBS), namely optical emission spectroscopy of laser-induced plasmas, have been constantly growing thanks to its intrinsic conceptual simplicity and versatility. Qualitative and quantitative analysis can be performed by LIBS both by drawing calibration lines and by using calibration-free methods and some of its features, so as fast multi-elemental response, micro-destructiveness, instrumentation portability, have rendered it particularly suitable for analytical applications in the field of environmental science, space exploration and cultural heritage. This review reports and discusses LIBS achievements in these areas and results obtained for soils and aqueous samples, meteorites and terrestrial samples simulating extraterrestrial planets, and cultural heritage samples, including buildings and objects of various kinds. PMID:22163611
Gaudiuso, Rosalba; Dell'Aglio, Marcella; De Pascale, Olga; Senesi, Giorgio S; De Giacomo, Alessandro
2010-01-01
Analytical applications of Laser Induced Breakdown Spectroscopy (LIBS), namely optical emission spectroscopy of laser-induced plasmas, have been constantly growing thanks to its intrinsic conceptual simplicity and versatility. Qualitative and quantitative analysis can be performed by LIBS both by drawing calibration lines and by using calibration-free methods and some of its features, so as fast multi-elemental response, micro-destructiveness, instrumentation portability, have rendered it particularly suitable for analytical applications in the field of environmental science, space exploration and cultural heritage. This review reports and discusses LIBS achievements in these areas and results obtained for soils and aqueous samples, meteorites and terrestrial samples simulating extraterrestrial planets, and cultural heritage samples, including buildings and objects of various kinds.
EDXRF analysis of the Pentecost Triptych from the "São Pedro de Miragaia" church (Porto, Portugal)
NASA Astrophysics Data System (ADS)
Roldán, Clodoaldo; Ferrero, José; Juanes, David; Carballo, Jorgelina; Calvo, Ana; Aguiar, Maria
2013-01-01
EDXRF spectrometry was used to determine the pigment composition of the Pentecost Triptych, a Flemish masterpiece located at the Church of São Pedro de Miragaia (Porto, Portugal). The triptych was restored at the beginning of the 20th century and presents a great number of zones with repaints and colour alterations that can be observed on the whole of their surface. The identification of the original pigments and restoration pigments was based on their characteristic colour and the correlation between the detected elements and the named "key elements" of ancient pigments (Ca, Fe, Cu, Hg, Pb,…) and modern pigments (Ti, Ba, Cr, Zn, Co, Cd,…). The analysis of the triptych has been carried out in situ by means of portable instrumentation.
46 CFR 119.458 - Portable fuel systems.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false Portable fuel systems. 119.458 Section 119.458 Shipping... Machinery Requirements § 119.458 Portable fuel systems. (a) Portable fuel systems, including portable tanks and related fuel lines and accessories, are prohibited except where used for portable dewatering pumps...
46 CFR 119.458 - Portable fuel systems.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Portable fuel systems. 119.458 Section 119.458 Shipping... Machinery Requirements § 119.458 Portable fuel systems. (a) Portable fuel systems, including portable tanks and related fuel lines and accessories, are prohibited except where used for portable dewatering pumps...
Manard, Benjamin T.; Wylie, E. Miller; Willson, Stephen P.
2018-05-22
In this paper, a portable handheld laser-induced breakdown spectroscopy (HH LIBS) instrument was evaluated as a rapid method to qualitatively analyze rare earth elements in a uranium oxide matrix. This research is motivated by the need for development of a method to perform rapid, at-line chemical analysis in a nuclear facility, particularly to provide a rapid first pass analysis to determine if additional actions or measurements are warranted. This will result in the minimization of handling and transport of radiological and nuclear material and subsequent exposure to their associated hazards. In this work, rare earth elements (Eu, Nd, and Yb)more » were quantitatively spiked into a uranium oxide powder and analyzed by the HH LIBS instrumentation. This method demonstrates the ability to rapidly identify elemental constituents in sub-percent levels in a uranium matrix. Preliminary limits of detection (LODs) were determined with values on the order of hundredths of a percent. Validity of this methodology was explored by employing a National Institute of Standards and Technology (NIST) standard reference materials (SRM) 610 and 612 (Trace Elements in Glass). Finally, it was determined that the HH LIBS method was able to clearly discern the rare earths elements of interest in the glass or uranium matrices.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Manard, Benjamin T.; Wylie, E. Miller; Willson, Stephen P.
In this paper, a portable handheld laser-induced breakdown spectroscopy (HH LIBS) instrument was evaluated as a rapid method to qualitatively analyze rare earth elements in a uranium oxide matrix. This research is motivated by the need for development of a method to perform rapid, at-line chemical analysis in a nuclear facility, particularly to provide a rapid first pass analysis to determine if additional actions or measurements are warranted. This will result in the minimization of handling and transport of radiological and nuclear material and subsequent exposure to their associated hazards. In this work, rare earth elements (Eu, Nd, and Yb)more » were quantitatively spiked into a uranium oxide powder and analyzed by the HH LIBS instrumentation. This method demonstrates the ability to rapidly identify elemental constituents in sub-percent levels in a uranium matrix. Preliminary limits of detection (LODs) were determined with values on the order of hundredths of a percent. Validity of this methodology was explored by employing a National Institute of Standards and Technology (NIST) standard reference materials (SRM) 610 and 612 (Trace Elements in Glass). Finally, it was determined that the HH LIBS method was able to clearly discern the rare earths elements of interest in the glass or uranium matrices.« less
Manard, Benjamin T; Wylie, E Miller; Willson, Stephen P
2018-01-01
A portable handheld laser-induced breakdown spectroscopy (HH LIBS) instrument was evaluated as a rapid method to qualitatively analyze rare earth elements in a uranium oxide matrix. This research is motivated by the need for development of a method to perform rapid, at-line chemical analysis in a nuclear facility, particularly to provide a rapid first pass analysis to determine if additional actions or measurements are warranted. This will result in the minimization of handling and transport of radiological and nuclear material and subsequent exposure to their associated hazards. In this work, rare earth elements (Eu, Nd, and Yb) were quantitatively spiked into a uranium oxide powder and analyzed by the HH LIBS instrumentation. This method demonstrates the ability to rapidly identify elemental constituents in sub-percent levels in a uranium matrix. Preliminary limits of detection (LODs) were determined with values on the order of hundredths of a percent. Validity of this methodology was explored by employing a National Institute of Standards and Technology (NIST) standard reference materials (SRM) 610 and 612 (Trace Elements in Glass). It was determined that the HH LIBS method was able to clearly discern the rare earths elements of interest in the glass or uranium matrices.
30 CFR 75.1100-2 - Quantity and location of firefighting equipment.
Code of Federal Regulations, 2012 CFR
2012-07-01
...-trip car, or personnel carrier shall be equipped with one portable fire extinguisher. (e) Electrical... loading point is provided with one of the following: (i) Two portable water cars; or (ii) Two portable chemical cars; or (iii) One portable water car or one portable chemical car, and either (a) a portable foam...
30 CFR 75.1100-2 - Quantity and location of firefighting equipment.
Code of Federal Regulations, 2013 CFR
2013-07-01
...-trip car, or personnel carrier shall be equipped with one portable fire extinguisher. (e) Electrical... loading point is provided with one of the following: (i) Two portable water cars; or (ii) Two portable chemical cars; or (iii) One portable water car or one portable chemical car, and either (a) a portable foam...
30 CFR 75.1100-2 - Quantity and location of firefighting equipment.
Code of Federal Regulations, 2014 CFR
2014-07-01
...-trip car, or personnel carrier shall be equipped with one portable fire extinguisher. (e) Electrical... loading point is provided with one of the following: (i) Two portable water cars; or (ii) Two portable chemical cars; or (iii) One portable water car or one portable chemical car, and either (a) a portable foam...
30 CFR 75.1100-2 - Quantity and location of firefighting equipment.
Code of Federal Regulations, 2010 CFR
2010-07-01
...-trip car, or personnel carrier shall be equipped with one portable fire extinguisher. (e) Electrical... loading point is provided with one of the following: (i) Two portable water cars; or (ii) Two portable chemical cars; or (iii) One portable water car or one portable chemical car, and either (a) a portable foam...
30 CFR 75.1100-2 - Quantity and location of firefighting equipment.
Code of Federal Regulations, 2011 CFR
2011-07-01
...-trip car, or personnel carrier shall be equipped with one portable fire extinguisher. (e) Electrical... loading point is provided with one of the following: (i) Two portable water cars; or (ii) Two portable chemical cars; or (iii) One portable water car or one portable chemical car, and either (a) a portable foam...
Improved Spacecraft Tracking and Navigation Using a Portable Radio Science Receiver
NASA Technical Reports Server (NTRS)
Soriano, Melissa; Jacobs, Christopher; Navarro, Robert; Naudet, Charles; Rogstad, Stephen; White, Leslie; Finley, Susan; Goodhart, Charles; Sigman, Elliott; Trinh, Joseph
2013-01-01
The Portable Radio Science Receiver (PRSR) is a suitcase-sized open-loop digital receiver designed to be small and easy to transport so that it can be deployed quickly and easily anywhere in the world. The PRSR digitizes, downconverts, and filters using custom hardware, firmware, and software. Up to 16 channels can be independently configured and recorded with a total data rate of up to 256 Mbps. The design and implementation of the system's hardware, firmware, and software is described. To minimize costs and time to deployment, our design leveraged elements of the hardware, firmware, and software designs from the existing full-sized operational (non-portable) Radio Science Receivers (RSR) and Wideband VLBI Science Receivers (WVSR), which have successfully supported flagship NASA deep space missions at all Deep Space Network (DSN) sites. We discuss a demonstration of the PRSR using VLBI, with one part per billion angular resolution: 1 nano-radian / 200 ?as synthesized beam. This is the highest resolution astronomical instrument ever operated solely from the Southern Hemisphere. Preliminary results from two sites are presented, including the European Space Agency (ESA) sites at Cebreros, Spain and Malargue, Argentina. Malargue's South American location is of special interest because it greatly improves the geometric coverage for spacecraft navigation in the Southern Hemisphere and will for the first time provide coverage to the 1/4 of the range of declination that has been excluded from reference frame work at Ka-band.
Portable apparatus for separating sample and detecting target analytes
Renzi, Ronald F.; Wally, Karl; Crocker, Robert W.; Stamps, James F.; Griffiths; Stewart K. ,; Fruetel, Julia A.; Horn, Brent A.; Shokair, Isaac R.; Yee, Daniel D.; VanderNoot, Victoria A.; Wiedenman, Boyd J.; West, Jason A. A.; Ferko, Scott M.
2008-11-18
Portable devices and methods for determining the presence of a target analyte using a portable device are provided. The portable device is preferably hand-held. A sample is injected to the portable device. A microfluidic separation is performed within the portable device and at least one separated component detected by a detection module within the portable device, in embodiments of the invention. A target analyte is identified, based on the separated component, and the presence of the target analyte is indicated on an output interface of the portable device, in accordance with embodiments of the invention.
NASA Technical Reports Server (NTRS)
Young, K. E.; Hodges, K. V.; Evans, C. A.
2012-01-01
While large-footprint X-ray fluorescence (XRF) instruments are reliable providers of elemental information about geologic samples, handheld XRF instruments are currently being developed that enable the collection of geochemical data in the field in short time periods (approx.60 seconds) [1]. These detectors are lightweight (1.3kg) and can provide elemental abundances of major rock forming elements heavier than Na. While handheld XRF detectors were originally developed for use in mining, we are working with commercially available instruments as prototypes to explore how portable XRF technology may enable planetary field science [2,3,4]. If an astronaut or robotic explorer visited another planetary surface, the ability to obtain and evaluate geochemical data in real-time would be invaluable, especially in the high-grading of samples to determine which should be returned to Earth. We present our results on the evaluation of handheld XRF technology as a geochemical tool in the context of planetary exploration.
Effect of bleaching gel in Ca, P and Zn content in tooth enamel evaluated by μ-EDXRF
NASA Astrophysics Data System (ADS)
Godinho, J.; Silveira, J.; Mata, A.; Carvalho, M. L.; Pessanha, S.
2014-10-01
The purpose of this in vitro study is to assess whether the elemental content of P, Ca and Zn in tooth enamel is altered when bleaching the teeth with bleaching gel. In order to perform this evaluation, sound vestibular surfaces of six anterior healthy teeth, extracted for periodontal or orthodontic reasons were used. Cuts were made in order to obtain 8 × 2 mm samples. Samples were then treated with the bleaching product (Opalescence PF 10%) accordingly to manufacturer instructions and stocked in artificial saliva between each application. The elemental content of each sample, before and after treatment was obtained by a portable micro Energy Dispersive X-ray Spectrometry (μ-EDXRF), making use of a polycapillary optic to obtain a focal spot of 100 μm for Fe-Kα. Quantitative calculations were obtained by WinAXIL compare mode method, using four standard reference materials. The obtained results show that no significant statistic differences were observed for the studied elements.
46 CFR 98.30-6 - Lifting a portable tank.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Lifting a portable tank. 98.30-6 Section 98.30-6... CONSTRUCTION, ARRANGEMENT, AND OTHER PROVISIONS FOR CERTAIN DANGEROUS CARGOES IN BULK Portable Tanks § 98.30-6 Lifting a portable tank. No person may lift a portable tank with another portable tank. [CGD 73-172, 39 FR...
Bassel, Léna; Motto-Ros, Vincent; Trichard, Florian; Pelascini, Frédéric; Ammari, Faten; Chapoulie, Rémy; Ferrier, Catherine; Lacanette, Delphine; Bousquet, Bruno
2017-01-01
Cave walls are affected by different kinds of alterations involving preservative issues in the case of ornate caves, in particular regarding the rock art covering the walls. In this context, coralloids correspond to a facies with popcorn-like aspect belonging to the speleothem family, mostly composed of calcium carbonate. The elemental characterization indicates the presence of elements that might be linked to the diagenesis and the expansion of the alterations as demonstrated by prior analyses on stalagmites. In this study, we report the use of laser-induced breakdown spectroscopy (LIBS) to characterize the elemental composition of one coralloid sample with a portable instrument allowing punctual measurements and a laboratory mapping setup delivering elemental images with spatial resolution at the micrometric scale, being particularly attentive to Mg, Sr, and Si identified as elements of interest. The complementarity of both instruments allows the determination of the internal structure of the coralloid. Although a validation based on a reference technique is necessary, LIBS data reveal that the external layer of the coralloid is composed of laminations correlated to variations of the LIBS signal of Si. In addition, an interstitial layer showing high LIBS signals for Fe, Al, and Si is interpreted to be a detrital clay interface between the external and the internal part of the coralloid. These preliminary results sustain a possible formation scenario of the coralloid by migration of the elements from the bedrock.
Ion beam analysis in cultural heritage studies: Milestones and perspectives
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dran, Jean-Claude; Calligaro, Thomas
2013-07-18
For three decades, ion beam analysis (IBA) in external mode was considered as the best choice for the characterisation of cultural heritage materials, as it combines excellent analytical performance and non-invasive character. However, in recent years, other analytical techniques arose as serious competitors, such as those based on synchrotron radiation (X-ray absorption, fluorescence or diffraction) or those using portable instruments (XRF, micro-Raman). It is shown that nevertheless IBA remains unmatched thanks to two unique features, namely the analysis of light elements and the high-resolution 3D chemical imaging.
NASA Astrophysics Data System (ADS)
Zelazny, Amy; Benson, Robert; Deegan, John; Walsh, Ken; Schmidt, W. David; Howe, Russell
2013-06-01
We describe the benefits to camera system SWaP-C associated with the use of aspheric molded glasses and optical polymers in the design and manufacture of optical components and elements. Both camera objectives and display eyepieces, typical for night vision man-portable EO/IR systems, are explored. We discuss optical trade-offs, system performance, and cost reductions associated with this approach in both visible and non-visible wavebands, specifically NIR and LWIR. Example optical models are presented, studied, and traded using this approach.
Dielectric Spectroscopy of Human Blood
NASA Astrophysics Data System (ADS)
Bernal-Alvarado, J.; Sosa, M.; Morales, L.; Hernández, L. C.; Hernández-Cabrera, F.; Palomares, P.; Juárez, P.; Ramírez, R.
2003-09-01
Using reactive strips of the Bayer's portable glucometer, as a container, the electric impedance spectrum of human blood was obtained. The results were fitted using the distributed element of the Cole-Cole model and the corresponding parameters were obtained. Several samples were studied and the result for the electric parameters, of the equivalent circuit, are reported -average value and standard deviation-. The samples were obtained from donors at the Guanajuato State Transfusion Center, at México; people were adult individuals in an aleatory sampling from healthy donors, they were free of hepatitis, and other diseases.
Evaluation of Lightweight, Relocatable Structures for Use in Theaters of Operations.
1982-05-01
ADA117 02& CONSTRUCTION ENGINEERING RESEARCH LAB (ARMY) CHAMPAIGN IL F/6 13/2EVALUATION OF LI HThEISHT, RELOCATABLE STRUCTURES FOR USE IN TH-ETC(U...NUMBER(s) M. Frisch J. LambertM._ Ptak 9. PERFORMING ORGANIZATION NAME AND ADDRESS 10. PROGRAM ELEMENT. PROJECT, TASK U.S. ARMY 4A 6 - T CONSTRUCTION ...System prefabricated buildings portable shelters 24L A2rRACT (C60901we S ,ewInd efb nOee -e and ldenif 7 by block numbe) The U.S. Army Construction
Optofluidics for handling and analysis of single living cells
NASA Astrophysics Data System (ADS)
Perozziello, Gerardo; Candeloro, Patrizio; Coluccio, Maria Laura; Di Fabrizio, Enzo
2017-11-01
Optofluidics is a field with important applications in areas such as biotechnology, chemical synthesis and analytical chemistry. Optofluidic devices combine optical elements into microfluidic devices in ways that increase portability and sensitivity of analysis for diagnostic or screening purposes .In fact in these devices fluids give fine adaptability, mobility and accessibility to nanoscale photonic devices which otherwise could not be realized using conventional devices. This review describes several cases inwhich optical or microfluidic approaches are used to trap single cells in proximity of integrated optical sensor for being analysed.
Inertial impaction air sampling device
Dewhurst, K.H.
1990-05-22
An inertial impactor is designed which is to be used in an air sampling device for collection of respirable size particles in ambient air. The device may include a graphite furnace as the impaction substrate in a small-size, portable, direct analysis structure that gives immediate results and is totally self-contained allowing for remote and/or personal sampling. The graphite furnace collects suspended particles transported through the housing by means of the air flow system, and these particles may be analyzed for elements, quantitatively and qualitatively, by atomic absorption spectrophotometry. 3 figs.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 49 Transportation 2 2014-10-01 2014-10-01 false Portable tanks, IM portable tanks, IBCs, Large Packagings, cargo tanks, and multi-unit tank car tanks. 174.63 Section 174.63 Transportation Other....63 Portable tanks, IM portable tanks, IBCs, Large Packagings, cargo tanks, and multi-unit tank car...
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 2 2010-10-01 2010-10-01 false Portable tanks, IM portable tanks, IBCs, Large Packagings, cargo tanks, and multi-unit tank car tanks. 174.63 Section 174.63 Transportation Other....63 Portable tanks, IM portable tanks, IBCs, Large Packagings, cargo tanks, and multi-unit tank car...
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 2 2011-10-01 2011-10-01 false Portable tanks, IM portable tanks, IBCs, Large Packagings, cargo tanks, and multi-unit tank car tanks. 174.63 Section 174.63 Transportation Other....63 Portable tanks, IM portable tanks, IBCs, Large Packagings, cargo tanks, and multi-unit tank car...
Code of Federal Regulations, 2013 CFR
2013-10-01
... 49 Transportation 2 2013-10-01 2013-10-01 false Portable tanks, IM portable tanks, IBCs, Large Packagings, cargo tanks, and multi-unit tank car tanks. 174.63 Section 174.63 Transportation Other....63 Portable tanks, IM portable tanks, IBCs, Large Packagings, cargo tanks, and multi-unit tank car...
Code of Federal Regulations, 2012 CFR
2012-10-01
... 49 Transportation 2 2012-10-01 2012-10-01 false Portable tanks, IM portable tanks, IBCs, Large Packagings, cargo tanks, and multi-unit tank car tanks. 174.63 Section 174.63 Transportation Other....63 Portable tanks, IM portable tanks, IBCs, Large Packagings, cargo tanks, and multi-unit tank car...
47 CFR 52.26 - NANC Recommendations on Local Number Portability Administration.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Portability Administration. 52.26 Section 52.26 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED... Number Portability Administration. (a) Local number portability administration shall comply with the... prepared by the NANC's Local Number Portability Administration Selection Working Group, dated April 25...
47 CFR 52.26 - NANC Recommendations on Local Number Portability Administration.
Code of Federal Regulations, 2013 CFR
2013-10-01
... Portability Administration. 52.26 Section 52.26 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED... Number Portability Administration. (a) Local number portability administration shall comply with the... prepared by the NANC's Local Number Portability Administration Selection Working Group, dated April 25...
A portable MPI-based parallel vector template library
NASA Technical Reports Server (NTRS)
Sheffler, Thomas J.
1995-01-01
This paper discusses the design and implementation of a polymorphic collection library for distributed address-space parallel computers. The library provides a data-parallel programming model for C++ by providing three main components: a single generic collection class, generic algorithms over collections, and generic algebraic combining functions. Collection elements are the fourth component of a program written using the library and may be either of the built-in types of C or of user-defined types. Many ideas are borrowed from the Standard Template Library (STL) of C++, although a restricted programming model is proposed because of the distributed address-space memory model assumed. Whereas the STL provides standard collections and implementations of algorithms for uniprocessors, this paper advocates standardizing interfaces that may be customized for different parallel computers. Just as the STL attempts to increase programmer productivity through code reuse, a similar standard for parallel computers could provide programmers with a standard set of algorithms portable across many different architectures. The efficacy of this approach is verified by examining performance data collected from an initial implementation of the library running on an IBM SP-2 and an Intel Paragon.
A Portable MPI-Based Parallel Vector Template Library
NASA Technical Reports Server (NTRS)
Sheffler, Thomas J.
1995-01-01
This paper discusses the design and implementation of a polymorphic collection library for distributed address-space parallel computers. The library provides a data-parallel programming model for C + + by providing three main components: a single generic collection class, generic algorithms over collections, and generic algebraic combining functions. Collection elements are the fourth component of a program written using the library and may be either of the built-in types of c or of user-defined types. Many ideas are borrowed from the Standard Template Library (STL) of C++, although a restricted programming model is proposed because of the distributed address-space memory model assumed. Whereas the STL provides standard collections and implementations of algorithms for uniprocessors, this paper advocates standardizing interfaces that may be customized for different parallel computers. Just as the STL attempts to increase programmer productivity through code reuse, a similar standard for parallel computers could provide programmers with a standard set of algorithms portable across many different architectures. The efficacy of this approach is verified by examining performance data collected from an initial implementation of the library running on an IBM SP-2 and an Intel Paragon.
Maruo, Yasuko Yamada; Nakamura, Jiro
2011-09-30
We have developed a portable device for formaldehyde monitoring with both high sensitivity and high temporal resolution, and carried out indoor air formaldehyde concentration analysis. The absorbance difference of the sensor element was measured in the monitoring device at regular intervals of, for example, one hour or 30 min, and the result was converted into the formaldehyde concentration. This was possible because we found that the lutidine derivative that was formed as a yellow product of the reaction between 1-phenyl-1,3-butandione and formaldehyde was stable in porous glass for at least six months. We estimated the reaction rate and to be 0.049 min(-1) and the reaction occurred quickly enough for us to monitor hourly changes in the formaldehyde concentration. The detection limit was 5 μg m(-3) h. We achieved hourly formaldehyde monitoring using the developed device under several indoor conditions, and estimated the air exchange rate and formaldehyde adsorption rate, which we adopted as a new term in the mass balance equation for formaldehyde, in one office. Copyright © 2011 Elsevier B.V. All rights reserved.
Development and testing of a portable wind sensitive directional air sampler
NASA Technical Reports Server (NTRS)
Deyo, J.; Toma, J.; King, R. B.
1975-01-01
A portable wind sensitive directional air sampler was developed as part of an air pollution source identification system. The system is designed to identify sources of air pollution based on the directional collection of field air samples and their analysis for TSP and trace element characteristics. Sources can be identified by analyzing the data on the basis of pattern recognition concepts. The unit, designated Air Scout, receives wind direction signals from an associated wind vane. Air samples are collected on filter slides using a standard high volume air sampler drawing air through a porting arrangement which tracks the wind direction and permits collection of discrete samples. A preset timer controls the length of time each filter is in the sampling position. At the conclusion of the sampling period a new filter is automatically moved into sampling position displacing the previous filter to a storage compartment. Thus the Air Scout may be set up at a field location, loaded with up to 12 filter slides, and left to acquire air samples automatically, according to the wind, at any timer interval desired from 1 to 30 hours.
NASA Astrophysics Data System (ADS)
Cannon, B. D.
1993-10-01
Isotopically-selective excitation of uranium atoms by diode lasers can be the basis for a portable instrument to perform uranium isotopic assays in the field. Such an instrument would improve the ability of on-site inspections to detect and deter nuclear proliferation. Published and unpublished spectroscopic data on atomic uranium were examined to identify candidate transitions for isotopically-selective laser excitation with diode lasers. Eleven candidate transitions were identified and evaluated for their potential usefulness for a portable uranium assay instrument. Eight of these transitions are suitable for laser induced fluorescence using different excitation and detection wavelengths, which will improve sensitivity and elemental selectivity. Data sheets on the 25 uranium transitions in the wavelength range 629 nm to 1,000 nm that originate in the ground or first excited states of neutral atomic uranium are included. Each data sheet provides the wavelength, upper and lower energy levels, angular momentum quantum numbers, U-235 isotope shift (relative to U-238, and high-resolution spectra of weapons-grade uranium (93% U-235 and 7% U-238).
Rapid cable tension estimation using dynamic and mechanical properties
NASA Astrophysics Data System (ADS)
Martínez-Castro, Rosana E.; Jang, Shinae; Christenson, Richard E.
2016-04-01
Main tension elements are critical to the overall stability of cable-supported bridges. A dependable and rapid determination of cable tension is desired to assess the state of a cable-supported bridge and evaluate its operability. A portable smart sensor setup is presented to reduce post-processing time and deployment complexity while reliably determining cable tension using dynamic characteristics extracted from spectral analysis. A self-recording accelerometer is coupled with a single-board microcomputer that communicates wirelessly with a remote host computer. The portable smart sensing device is designed such that additional algorithms, sensors and controlling devices for various monitoring applications can be installed and operated for additional structural assessment. The tension-estimating algorithms are based on taut string theory and expand to consider bending stiffness. The successful combination of cable properties allows the use of a cable's dynamic behavior to determine tension force. The tension-estimating algorithms are experimentally validated on a through-arch steel bridge subject to ambient vibration induced by passing traffic. The tension estimation is determined in well agreement with previously determined tension values for the structure.
NASA Astrophysics Data System (ADS)
Siozos, Panagiotis; Philippidis, Aggelos; Anglos, Demetrios
2017-11-01
A novel, portable spectrometer, combining two analytical techniques, laser-induced breakdown spectroscopy (LIBS) and diffuse reflectance spectroscopy, was developed with the aim to provide an enhanced instrumental and methodological approach with regard to the analysis of pigments in objects of cultural heritage. Technical details about the hybrid spectrometer and its operation are presented and examples are given relevant to the analysis of paint materials. Both LIBS and diffuse reflectance spectra in the visible and part of the near infrared, corresponding to several neat mineral pigment samples, were recorded and the complementary information was used to effectively distinguish different types of pigments even if they had similar colour or elemental composition. The spectrometer was also employed in the analysis of different paints on the surface of an ancient pottery sherd demonstrating the capabilities of the proposed hybrid diagnostic approach. Despite its instrumental simplicity and compact size, the spectrometer is capable of supporting analytical campaigns relevant to archaeological, historical or art historical investigations, particularly when quick data acquisition is required in the context of surveys of large numbers of objects and samples.
47 CFR 90.1333 - Restrictions on the operation of mobile and portable stations.
Code of Federal Regulations, 2010 CFR
2010-10-01
... transmitted by a base station. (b) Any mobile/portable stations may communicate with any other mobile/portable... by a base station. (c) Airborne operations by mobile/portable stations is prohibited. ... portable stations. 90.1333 Section 90.1333 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED...
46 CFR 182.458 - Portable fuel systems.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 7 2013-10-01 2013-10-01 false Portable fuel systems. 182.458 Section 182.458 Shipping...) MACHINERY INSTALLATION Specific Machinery Requirements § 182.458 Portable fuel systems. (a) Portable fuel systems, including portable tanks and related fuel lines and accessories, are prohibited except where used...
46 CFR 182.458 - Portable fuel systems.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 7 2010-10-01 2010-10-01 false Portable fuel systems. 182.458 Section 182.458 Shipping...) MACHINERY INSTALLATION Specific Machinery Requirements § 182.458 Portable fuel systems. (a) Portable fuel systems, including portable tanks and related fuel lines and accessories, are prohibited except where used...
46 CFR 182.458 - Portable fuel systems.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 7 2011-10-01 2011-10-01 false Portable fuel systems. 182.458 Section 182.458 Shipping...) MACHINERY INSTALLATION Specific Machinery Requirements § 182.458 Portable fuel systems. (a) Portable fuel systems, including portable tanks and related fuel lines and accessories, are prohibited except where used...
46 CFR 169.743 - Portable magazine chests.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 7 2010-10-01 2010-10-01 false Portable magazine chests. 169.743 Section 169.743... Vessel Control, Miscellaneous Systems, and Equipment Markings § 169.743 Portable magazine chests. Portable magazine chests must be marked in letters at least 3 inches high: “PORTABLE MAGAZINE CHEST...
30 CFR 18.35 - Portable (trailing) cables and cords.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Portable (trailing) cables and cords. 18.35... and Design Requirements § 18.35 Portable (trailing) cables and cords. (a) Portable cables and cords... a portable (trailing) cable shall not exceed 500 feet. Where the method of mining requires the...
46 CFR 195.11-30 - Portable tanks.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 7 2014-10-01 2014-10-01 false Portable tanks. 195.11-30 Section 195.11-30 Shipping... AND MISCELLANEOUS SYSTEMS AND EQUIPMENT Portable Vans and Tanks § 195.11-30 Portable tanks. (a) All portable tanks, whether hazardous or nonhazardous commodities, shall be loaded and stowed in accordance...
46 CFR 195.11-30 - Portable tanks.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 7 2013-10-01 2013-10-01 false Portable tanks. 195.11-30 Section 195.11-30 Shipping... AND MISCELLANEOUS SYSTEMS AND EQUIPMENT Portable Vans and Tanks § 195.11-30 Portable tanks. (a) All portable tanks, whether hazardous or nonhazardous commodities, shall be loaded and stowed in accordance...
46 CFR 195.11-30 - Portable tanks.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 7 2010-10-01 2010-10-01 false Portable tanks. 195.11-30 Section 195.11-30 Shipping... AND MISCELLANEOUS SYSTEMS AND EQUIPMENT Portable Vans and Tanks § 195.11-30 Portable tanks. (a) All portable tanks, whether hazardous or nonhazardous commodities, shall be loaded and stowed in accordance...
46 CFR 195.11-30 - Portable tanks.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 7 2011-10-01 2011-10-01 false Portable tanks. 195.11-30 Section 195.11-30 Shipping... AND MISCELLANEOUS SYSTEMS AND EQUIPMENT Portable Vans and Tanks § 195.11-30 Portable tanks. (a) All portable tanks, whether hazardous or nonhazardous commodities, shall be loaded and stowed in accordance...
46 CFR 195.11-30 - Portable tanks.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 7 2012-10-01 2012-10-01 false Portable tanks. 195.11-30 Section 195.11-30 Shipping... AND MISCELLANEOUS SYSTEMS AND EQUIPMENT Portable Vans and Tanks § 195.11-30 Portable tanks. (a) All portable tanks, whether hazardous or nonhazardous commodities, shall be loaded and stowed in accordance...
49 CFR 180.603 - Qualification of portable tanks.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 49 Transportation 3 2013-10-01 2013-10-01 false Qualification of portable tanks. 180.603 Section... MAINTENANCE OF PACKAGINGS Qualification and Maintenance of Portable Tanks § 180.603 Qualification of portable tanks. (a) Each portable tank used for the transportation of hazardous materials must be an authorized...
46 CFR 2.75-25 - Portable fire extinguishers.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 1 2010-10-01 2010-10-01 false Portable fire extinguishers. 2.75-25 Section 2.75-25... Personnel § 2.75-25 Portable fire extinguishers. (a) The portable fire extinguishers listed and labeled as..., inclusive. (b) The procedures for manufacturers to follow and the requirements governing portable fire...
21 CFR 868.5655 - Portable liquid oxygen unit.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Portable liquid oxygen unit. 868.5655 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5655 Portable liquid oxygen unit. (a) Identification. A portable liquid oxygen unit is a portable, thermally insulated container of liquid oxygen that...
21 CFR 868.5655 - Portable liquid oxygen unit.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Portable liquid oxygen unit. 868.5655 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5655 Portable liquid oxygen unit. (a) Identification. A portable liquid oxygen unit is a portable, thermally insulated container of liquid oxygen that...
21 CFR 868.5655 - Portable liquid oxygen unit.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Portable liquid oxygen unit. 868.5655 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5655 Portable liquid oxygen unit. (a) Identification. A portable liquid oxygen unit is a portable, thermally insulated container of liquid oxygen that...
21 CFR 868.5655 - Portable liquid oxygen unit.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Portable liquid oxygen unit. 868.5655 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5655 Portable liquid oxygen unit. (a) Identification. A portable liquid oxygen unit is a portable, thermally insulated container of liquid oxygen that...
21 CFR 868.5655 - Portable liquid oxygen unit.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Portable liquid oxygen unit. 868.5655 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5655 Portable liquid oxygen unit. (a) Identification. A portable liquid oxygen unit is a portable, thermally insulated container of liquid oxygen that...
46 CFR 108.651 - Portable magazine chests.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Portable magazine chests. 108.651 Section 108.651... AND EQUIPMENT Equipment Markings and Instructions § 108.651 Portable magazine chests. Each portable magazine chest must be marked: “PORTABLE MAGAZINE CHEST—FLAMMABLE—KEEP LIGHTS AND FIRE AWAY” in letters at...
47 CFR 80.1189 - Portable ship earth stations.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 5 2010-10-01 2010-10-01 false Portable ship earth stations. 80.1189 Section....1189 Portable ship earth stations. (a) Portable ship earth stations are authorized to operate on board more than one ship. Portable ship earth stations are also authorized to be operated on board fixed...
47 CFR 80.1189 - Portable ship earth stations.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 47 Telecommunication 5 2011-10-01 2011-10-01 false Portable ship earth stations. 80.1189 Section....1189 Portable ship earth stations. (a) Portable ship earth stations are authorized to operate on board more than one ship. Portable ship earth stations are also authorized to be operated on board fixed...
47 CFR 80.1189 - Portable ship earth stations.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 47 Telecommunication 5 2014-10-01 2014-10-01 false Portable ship earth stations. 80.1189 Section....1189 Portable ship earth stations. (a) Portable ship earth stations are authorized to operate on board more than one ship. Portable ship earth stations are also authorized to be operated on board fixed...
47 CFR 80.1189 - Portable ship earth stations.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 47 Telecommunication 5 2013-10-01 2013-10-01 false Portable ship earth stations. 80.1189 Section....1189 Portable ship earth stations. (a) Portable ship earth stations are authorized to operate on board more than one ship. Portable ship earth stations are also authorized to be operated on board fixed...
47 CFR 80.1189 - Portable ship earth stations.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 47 Telecommunication 5 2012-10-01 2012-10-01 false Portable ship earth stations. 80.1189 Section....1189 Portable ship earth stations. (a) Portable ship earth stations are authorized to operate on board more than one ship. Portable ship earth stations are also authorized to be operated on board fixed...
29 CFR 1915.172 - Portable air receivers and other unfired pressure vessels.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 29 Labor 7 2012-07-01 2012-07-01 false Portable air receivers and other unfired pressure vessels... SHIPYARD EMPLOYMENT Portable, Unfired Pressure Vessels, Drums and Containers, Other Than Ship's Equipment § 1915.172 Portable air receivers and other unfired pressure vessels. (a) Portable, unfired pressure...
29 CFR 1915.172 - Portable air receivers and other unfired pressure vessels.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 29 Labor 7 2013-07-01 2013-07-01 false Portable air receivers and other unfired pressure vessels... SHIPYARD EMPLOYMENT Portable, Unfired Pressure Vessels, Drums and Containers, Other Than Ship's Equipment § 1915.172 Portable air receivers and other unfired pressure vessels. (a) Portable, unfired pressure...
29 CFR 1915.172 - Portable air receivers and other unfired pressure vessels.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 29 Labor 7 2014-07-01 2014-07-01 false Portable air receivers and other unfired pressure vessels... SHIPYARD EMPLOYMENT Portable, Unfired Pressure Vessels, Drums and Containers, Other Than Ship's Equipment § 1915.172 Portable air receivers and other unfired pressure vessels. (a) Portable, unfired pressure...
NASA Technical Reports Server (NTRS)
Clements, Anna L.; Carlile, Christie; Graf, John; Young, Gina
2011-01-01
NASA is developing a Fine Water Mist (FWM) Portable Fire Extinguisher (PFE) for use on the International Space Station. The International Space Station presently uses two different types of fire extinguishers: a water foam extinguisher in the Russian Segment, and a carbon dioxide extinguisher in the US Segment and Columbus and Kibo pressurized elements. Changes in emergency breathing equipment make Fine Water Mist operationally preferable. Supplied oxygen breathing systems allow for safe discharge of a carbon dioxide fire extinguisher, without concerns of the crew inhaling unsafe levels of carbon dioxide. But the Portable Breathing Apparatus (PBA) offers no more than 15 minutes of capability, and continued use of hose based supplied oxygen system increases the oxygen content in a fire situation. NASA has developed a filtering respirator cartridge for use in a fire environment. It is qualified to provide up to 90 minutes of capability, and because it is a filtering respirator it does not add oxygen to the environment. The fire response respirator cartridge does not filter carbon dioxide (CO2), so a crew member discharging a CO2 fire extinguisher while wearing this filtering respirator would be at risk of inhaling unsafe levels of CO2. FWM extinguishes a fire without creating a large volume of air with reduced oxygen and elevated CO2. The following paper will discuss the unique functional and performance requirements that have been levied on the FWM PFE. In addition, the NASA ISS specific fire standards will be described which were developed to establish acceptable extinguisher performance. The paper will also discuss the flight hardware design. The fin e water mist fire extinguisher has two major elements: (1) the nozzle and crew interface, and (2) the tank. The nozzle and crew interface have been under development for several years. They have gone through several design iterations, and have been part of more than 400 fire challenge and spray characterizations. The crew and vehicle interface aspects of the design will use the heritage of the CO2 based Portable Fire Extinguisher, to minimize the disruption to the crew and integration impacts to the ISS. The microgravity use environment of the system poses a set of unique design requirements specifically for the tank. The nozzle requirements drive a tank pressure that is 2-5 times higher than any commercially available water mist systems. Microgravity requires deliberate separation of gas and water, facilitated by a bladder, a diaphragm, a piston, or separate tanks. This paper will describe status of the project to date, the design details of the tank and the nozzle, and discuss the trade studies that informed the decisions to select the tank and nozzle configuration.
Analysis of Thick Sandwich Shells with Embedded Ceramic Tiles
NASA Technical Reports Server (NTRS)
Davila, Carlos G.; Smith, C.; Lumban-Tobing, F.
1996-01-01
The Composite Armored Vehicle (CAV) is an advanced technology demonstrator of an all-composite ground combat vehicle. The CAV upper hull is made of a tough light-weight S2-glass/epoxy laminate with embedded ceramic tiles that serve as armor. The tiles are bonded to a rubber mat with a carefully selected, highly viscoelastic adhesive. The integration of armor and structure offers an efficient combination of ballistic protection and structural performance. The analysis of this anisotropic construction, with its inherent discontinuous and periodic nature, however, poses several challenges. The present paper describes a shell-based 'element-layering' technique that properly accounts for these effects and for the concentrated transverse shear flexibility in the rubber mat. One of the most important advantages of the element-layering technique over advanced higher-order elements is that it is based on conventional elements. This advantage allows the models to be portable to other structural analysis codes, a prerequisite in a program that involves the computational facilities of several manufacturers and government laboratories. The element-layering technique was implemented into an auto-layering program that automatically transforms a conventional shell model into a multi-layered model. The effects of tile layer homogenization, tile placement patterns, and tile gap size on the analysis results are described.
NASA Astrophysics Data System (ADS)
Van de Voorde, Lien; Van Pevenage, Jolien; De Langhe, Kaat; De Wolf, Robin; Vekemans, Bart; Vincze, Laszlo; Vandenabeele, Peter; Martens, Maximiliaan P. J.
2014-07-01
"Mad Meg", a figure of Flemish folklore, is the subject of a famous oil-on-panel painting by the Flemish renaissance artist Pieter Bruegel the Elder, exhibited in the Museum Mayer van den Bergh (Antwerp, Belgium). This article reports on the in situ chemical characterization of this masterpiece by using currently available state-of-the-art portable analytical instruments. The applied non-destructive analytical approach involved the use of a) handheld X-ray fluorescence instrumentation for retrieving elemental information and b) portable X-ray fluorescence/X-ray diffraction instrumentation and laser-based Raman spectrometers for obtaining structural/molecular information. Next to material characterization of the used pigments and of the different preparation layers of the painting, also the verification of two important historical iconographic hypotheses is performed concerning the economic way of painting by Brueghel, and whether or not he used blue smalt pigment for painting the boat that appears towards the top of the painting. The pigments identified are smalt pigment (65% SiO2 + 15% K2O + 10% CoO + 5% Al2O3) for the blue color present in all blue areas of the painting, probably copper resinate for the green colors, vermillion (HgS) as red pigment and lead white is used to form different colors. The comparison of blue pigments used on different areas of the painting gives no differences in the elemental fingerprint which confirms the existing hypothesis concerning the economic painting method by Bruegel.
NASA Astrophysics Data System (ADS)
Nikitczuk, Jason; Weinberg, Brian; Mavroidis, Constantinos
2006-03-01
In this paper we present the design and control algorithms for novel electro-rheological fluid based torque generation elements that will be used to drive the joint of a new type of portable and controllable Active Knee Rehabilitation Orthotic Device (AKROD) for gait retraining in stroke patients. The AKROD is composed of straps and rigid components for attachment to the leg, with a central hinge mechanism where a gear system is connected. The key features of AKROD include: a compact, lightweight design with highly tunable torque capabilities through a variable damper component, full portability with on board power, control circuitry, and sensors (encoder and torque), and real-time capabilities for closed loop computer control for optimizing gait retraining. The variable damper component is achieved through an electro-rheological fluid (ERF) element that connects to the output of the gear system. Using the electrically controlled rheological properties of ERFs, compact brakes capable of supplying high resistive and controllable torques, are developed. A preliminary prototype for AKROD v.2 has been developed and tested in our laboratory. AKROD's v.2 ERF resistive actuator was tested in laboratory experiments using our custom made ERF Testing Apparatus (ETA). ETA provides a computer controlled environment to test ERF brakes and actuators in various conditions and scenarios including emulating the interaction between human muscles involved with the knee and AKROD's ERF actuators / brakes. In our preliminary results, AKROD's ERF resistive actuator was tested in closed loop torque control experiments. A hybrid (non-linear, adaptive) Proportional-Integral (PI) torque controller was implemented to achieve this goal.
NASA Astrophysics Data System (ADS)
Papadopoulou, D. N.; Zachariadis, G. A.; Anthemidis, A. N.; Tsirliganis, N. C.; Stratis, J. A.
2004-12-01
Two multielement instrumental methods of analysis, micro X-ray fluorescence spectrometry (micro-XRF) and inductively coupled plasma atomic emission spectrometry (ICP-AES) were applied for the analysis of 7th and 5th century B.C. ancient ceramic sherds in order to evaluate the above two methods and to assess the potential to use the current compact and portable micro-XRF instrument for the in situ analysis of ancient ceramics. The distinguishing factor of interest is that micro-XRF spectrometry offers the possibility of a nondestructive analysis, an aspect of primary importance in the compositional analysis of cultural objects. Micro-XRF measurements were performed firstly directly on the ceramic sherds with no special pretreatment apart from surface cleaning (micro-XRF on sherds) and secondly on pressed pellet disks which were prepared for each ceramic sherd (micro-XRF on pellet). For the ICP-AES determination of elements, test solutions were prepared by the application of a microwave-assisted decomposition procedure in closed high-pressure PFA vessels. Also, the standard reference material SARM 69 was used for the efficiency calibration of the micro-XRF instrument and was analysed by both methods. In order to verify the calibration, the standard reference materials NCS DC 73332 and SRM620 as well as the reference materials AWI-1 and PRI-1 were analysed by micro-XRF. Elemental concentrations determined by the three analytical procedures (ICP-AES, micro-XRF on sherds and micro-XRF on pellets) were statistically treated by correlation analysis and Student's t-test (at the 95% confidence level).
Ferenchick, Gary; Solomon, David; Durning, Steven J
2010-01-01
Portable computers are widely used by medical trainees, but there is a lack of data on how these devices are used in clinical education programs. The objective is to define the current use of portable computing in internal medicine clerkships and to determine medicine clerkship directors' perceptions of the current value and future importance of portable computing. A 2006 national survey of institutional members of the Clerkship Directors in Internal Medicine. Eighty-three of 110 (75%) of institutional members responded. An institutional requirement for portable computing was reported by 32 schools (39%), whereas only 13 (16%) provided students with a portable computer. Between 10 and 31 institutions (12-37%) reported student use for patient care activities (i.e. order entry, writing patient notes) and only 2 to 4 institutions (2-5%) required such use. The majority of respondents (59-95%) reported portable computer use for educational activities (i.e., tracking patient problems, knowledge resource), however, only in 5 to 19 (6-23%) were such educational uses required. Fifty-six respondents (68%) reported that portable computer's "added value" for teaching and 61 (73%) reported that portable computers would be important in meeting clerkship objectives in the next 3 years. Of interest, even among the institutions requiring portable computers, only 50% recommended or required specific software. Portable computing is required at 39% of allopathic medical schools in the United States. However required portable computing for specific patient care or educational tasks is uncommon. In addition, guidance on specific software exists in only one half of school requiring portable computers, suggesting informal or unstructured uses of required portable computer's in the remaining half. The educational impact of formal institutional requirements for software versus informal "user-defined" applications is unknown.
29 CFR 1917.119 - Portable ladders.
Code of Federal Regulations, 2011 CFR
2011-07-01
... (CONTINUED) MARINE TERMINALS Terminal Facilities § 1917.119 Portable ladders. (a) Scope and applicability... Requirements for Portable Reinforced Plastic Ladders (d) Standards for job-made portable ladders. Job-made...
49 CFR 173.32 - Requirements for the use of portable tanks.
Code of Federal Regulations, 2014 CFR
2014-10-01
... portable tanks. (1) The bursting strength of any piping and fittings must be at least four times the design... specified portable tank must meet the same design profile; for example, a DOT Specification 51 portable tank... manufactured portable tanks must conform to the requirements for the design, construction and approval of UN...
40 CFR 59.615 - How must I label and identify the portable fuel containers I produce?
Code of Federal Regulations, 2010 CFR
2010-07-01
... portable fuel containers I produce? 59.615 Section 59.615 Protection of Environment ENVIRONMENTAL... FOR CONSUMER AND COMMERCIAL PRODUCTS Control of Evaporative Emissions From New and In-Use Portable... portable fuel containers I produce? This section describes how you must label your portable fuel containers...
46 CFR 78.47-70 - Portable magazine chests.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 3 2010-10-01 2010-10-01 false Portable magazine chests. 78.47-70 Section 78.47-70... Fire and Emergency Equipment, Etc. § 78.47-70 Portable magazine chests. (a) Portable magazine chest shall be marked in letters of at least 3 inches high “PORTABLE MAGAZINE CHEST—FLAMMABLE—KEEP LIGHTS AND...
46 CFR 97.37-47 - Portable magazine chests.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Portable magazine chests. 97.37-47 Section 97.37-47... OPERATIONS Markings for Fire and Emergency Equipment, Etc. § 97.37-47 Portable magazine chests. (a) Portable magazine chests shall be marked in letters at least 3 inches high: “PORTABLE MAGAZINE CHEST—FLAMMABLE—KEEP...
46 CFR 196.37-47 - Portable magazine chests.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 7 2010-10-01 2010-10-01 false Portable magazine chests. 196.37-47 Section 196.37-47... Markings for Fire and Emergency Equipment, etc. § 196.37-47 Portable magazine chests. (a) Portable magazine chests shall be marked in letters at least 3 inches high: PORTABLE MAGAZINE CHEST — FLAMMABLE — KEEP...
Design criteria for portable timber bridge systems : static versus dynamic loads
John M. Franklin; S. E. Taylor; Paul A. Morgan; M. A. Ritter
1999-01-01
Design criteria are needed specifically for portable bridges to insure that they are safe and cost effective. This paper discusses different portable bridge categories and their general design criteria. Specific emphasis is given to quantifying the effects of dynamic live loads on portable bridge design. Results from static and dynamic load tests of two portable timber...
Assessing arsenic and selenium in a single nail clipping using portable X-ray fluorescence.
Fleming, David E B; Nader, Michel N; Foran, Kelly A; Groskopf, Craig; Reno, Michael C; Ware, Chris S; Tehrani, Mina; Guimarães, Diana; Parsons, Patrick J
2017-02-01
The feasibility of measuring arsenic and selenium contents in a single nail clipping was investigated using a small-focus portable X-ray fluorescence (XRF) instrument with monochromatic excitation beams. Nail clipping phantoms supplemented with arsenic and selenium to produce materials with 0, 5, 10, 15, and 20µg/g were used for calibration purposes. In total, 10 different clippings were analyzed at two different measurement positions. Energy spectra were fit with detection peaks for arsenic K α , selenium K α , arsenic K β , selenium K β , and bromine K α characteristic X-rays. Data analysis was performed under two distinct conditions of fitting constraint. Calibration lines were established from the amplitude of each of the arsenic and selenium peaks as a function of the elemental contents in the clippings. The slopes of the four calibration lines were consistent between the two conditions of analysis. The calculated minimum detection limit (MDL) of the method, when considering the K α peak only, ranged from 0.210±0.002µg/g selenium under one condition of analysis to 0.777±0.009µg/g selenium under another. Compared with previous portable XRF nail clipping studies, MDLs were substantially improved for both arsenic and selenium. The new measurement technique had the additional benefits of being short in duration (~3min) and requiring only a single nail clipping. The mass of the individual clipping used did not appear to play a major role in signal strength, but positioning of the clipping is important. Copyright © 2016 Elsevier Ltd. All rights reserved.
40 CFR 59.653 - How do I test portable fuel containers?
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 6 2012-07-01 2012-07-01 false How do I test portable fuel containers... Families § 59.653 How do I test portable fuel containers? You must test the portable fuel container as.... Perform a slosh test by filling the portable fuel container to 40 percent of its capacity with the fuel...
40 CFR 59.653 - How do I test portable fuel containers?
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 6 2013-07-01 2013-07-01 false How do I test portable fuel containers... Families § 59.653 How do I test portable fuel containers? You must test the portable fuel container as.... Perform a slosh test by filling the portable fuel container to 40 percent of its capacity with the fuel...
40 CFR 59.653 - How do I test portable fuel containers?
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 6 2014-07-01 2014-07-01 false How do I test portable fuel containers... Families § 59.653 How do I test portable fuel containers? You must test the portable fuel container as.... Perform a slosh test by filling the portable fuel container to 40 percent of its capacity with the fuel...
Method and apparatus for multiple-projection, dual-energy x-ray absorptiometry scanning
NASA Technical Reports Server (NTRS)
Feldmesser, Howard S. (Inventor); Magee, Thomas C. (Inventor); Charles, Jr., Harry K. (Inventor); Beck, Thomas J. (Inventor)
2007-01-01
Methods and apparatuses for advanced, multiple-projection, dual-energy X-ray absorptiometry scanning systems include combinations of a conical collimator; a high-resolution two-dimensional detector; a portable, power-capped, variable-exposure-time power supply; an exposure-time control element; calibration monitoring; a three-dimensional anti-scatter-grid; and a gantry-gantry base assembly that permits up to seven projection angles for overlapping beams. Such systems are capable of high precision bone structure measurements that can support three dimensional bone modeling and derivations of bone strength, risk of injury, and efficacy of countermeasures among other properties.
NASA Astrophysics Data System (ADS)
Jackson, Gerald P.
The production of commercial quantities of antiprotons has been a reality for many years now. The deceleration and trapping of antiprotons is a relatively new activity, but has been sufficiently proven to be translated into a business enterprise. Now that NASA has a portable Penning trap for transporting antiprotons, all the elements are in place to begin the commercial distribution of antiprotons. The list of potential customers for antiprotons is continuously growing, with detailed market analyses already performed on some medical and propulsion applications. In this paper these applications are reviewed, along with their appetite for antiprotons and the steps needed to bring them to market.
Quantitative measuring system for combustible gas with audible tick rate
DOE Office of Scientific and Technical Information (OSTI.GOV)
Batz, J.E.
1979-09-04
Northern Illinois Gas Co.'s new gas-detection instrument is lightweight, portable, easy to use, and in compliance with industry standards as an intrinsically safe device. The instrument uses a semiconductor gas-sensor element energyzed with the regulated voltage source. Placed in the atmosphere to be tested, the detector generates a signal representative of the concentration of natural gas in the air. A meter displays the signal to determine whether the area is hazardous; a variable-repetition-rate blocking oscillator feeding a speaker responds to the signal, generating an audible tick rate useful in locating a leak.
Volatile organic compound sensor system
Schabron, John F [Laramie, WY; Rovani, Jr., Joseph F.; Bomstad, Theresa M [Laramie, WY; Sorini-Wong, Susan S [Laramie, WY
2009-02-10
Generally, this invention relates to the development of field monitoring methodology for new substances and sensing chemical warfare agents (CWAs) and terrorist substances. It also relates to a portable test kit which may be utilized to measure concentrations of halogenated volatile organic compounds (VOCs) in the field. Specifically it relates to systems for reliably field sensing the potential presence of such items while also distinguishing them from other elements potentially present. It also relates to overall systems and processes for sensing, reacting, and responding to an indicated presence of such substance, including modifications of existing halogenated sensors and arrayed sensing systems and methods.
Volatile organic compound sensor system
Schabron, John F.; Rovani, Jr., Joseph F.; Bomstad, Theresa M.; Sorini-Wong, Susan S.; Wong, Gregory K.
2011-03-01
Generally, this invention relates to the development of field monitoring methodology for new substances and sensing chemical warfare agents (CWAs) and terrorist substances. It also relates to a portable test kit which may be utilized to measure concentrations of halogenated volatile organic compounds (VOCs) in the field. Specifically it relates to systems for reliably field sensing the potential presence of such items while also distinguishing them from other elements potentially present. It also relates to overall systems and processes for sensing, reacting, and responding to an indicated presence of such substance, including modifications of existing halogenated sensors and arrayed sensing systems and methods.
Portable Medical Laboratory Applications Software
Silbert, Jerome A.
1983-01-01
Portability implies that a program can be run on a variety of computers with minimal software revision. The advantages of portability are outlined and design considerations for portable laboratory software are discussed. Specific approaches for achieving this goal are presented.
Classifying threats with a 14-MeV neutron interrogation system.
Strellis, Dan; Gozani, Tsahi
2005-01-01
SeaPODDS (Sea Portable Drug Detection System) is a non-intrusive tool for detecting concealed threats in hidden compartments of maritime vessels. This system consists of an electronic neutron generator, a gamma-ray detector, a data acquisition computer, and a laptop computer user-interface. Although initially developed to detect narcotics, recent algorithm developments have shown that the system is capable of correctly classifying a threat into one of four distinct categories: narcotic, explosive, chemical weapon, or radiological dispersion device (RDD). Detection of narcotics, explosives, and chemical weapons is based on gamma-ray signatures unique to the chemical elements. Elements are identified by their characteristic prompt gamma-rays induced by fast and thermal neutrons. Detection of RDD is accomplished by detecting gamma-rays emitted by common radioisotopes and nuclear reactor fission products. The algorithm phenomenology for classifying threats into the proper categories is presented here.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cushman, R. M.; Hildebrand, S. G.; Strand, R. H.
1977-06-01
Data are tabulated on the toxicity to freshwater biota of 35 trace elements with the potential for release to the environment from coal conversion effluents. The entire data base is presented on a microfiche appended to the document, in the interest of portability and accessibility. The data were gathered from a variety of research papers, compendia, and reviews. Details of water chemistry and test conditions are presented when available from the documents consulted. The data base may be used by referring directly to the tabulated data as they appear on the microfiche, or, with appropriate computer facilities, by manipulation (sorting,more » subsetting, or merging) of the data to meet the particular needs of the investigator. The data may be used as they appear in the data base, or the data base may be used to index the cited original papers.« less
NASA Technical Reports Server (NTRS)
Loftin, Karin C.; Ly, Bebe; Webster, Laurie; Verlander, James; Taylor, Gerald R.; Riley, Gary; Culbert, Chris
1992-01-01
One of NASA's goals for long duration space flight is to maintain acceptable levels of crew health, safety, and performance. One way of meeting this goal is through BRAIN, an integrated network of both human and computer elements. BRAIN will function as an advisor to mission managers by assessing the risk of inflight biomedical problems and recommending appropriate countermeasures. Described here is a joint effort among various NASA elements to develop BRAIN and the Infectious Disease Risk Assessment (IDRA) prototype. The implementation of this effort addresses the technological aspects of knowledge acquisition, integration of IDRA components, the use of expert systems to automate the biomedical prediction process, development of a user friendly interface, and integration of IDRA and ExerCISys systems. Because C language, CLIPS and the X-Window System are portable and easily integrated, they were chosen ss the tools for the initial IDRA prototype.
NASA Astrophysics Data System (ADS)
Wang, Han; Gou, Chao; Luo, Kai
2017-04-01
This paper presents a fully on-chip NMOS low-dropout regulator (LDO) for portable applications with quasi floating gate pass element and fast transient response. The quasi floating gate structure makes the gate of the NMOS transistor only periodically charged or refreshed by the charge pump, which allows the charge pump to be a small economical circuit with small silicon area. In addition, a variable reference circuit is introduced enlarging the dynamic range of error amplifier during load transient. The proposed LDO has been implemented in a 0.35 μm BCD process. From experimental results, the regulator can operate with a minimum dropout voltage of 250 mV at a maximum 1 A load and {I}{{Q}} of 395 μA. Under full-range load current step, the voltage undershoot and overshoot of the proposed LDO are reduced to 50 and 26 mV, respectively.
NASA Astrophysics Data System (ADS)
Latif, A. Afiff; Ibrahim, M. Rasidi; Rahim, E. A.; Cheng, K.
2017-04-01
The conventional milling has many difficulties in the processing of hard and brittle material. Hence, ultrasonic vibration assisted milling (UVAM) was proposed to overcome this problem. The objective of this research is to study the behavior of compliance mechanism (CM) as the critical part affect the performance of the UVAM. The design of the CM was investigated and focuses on 1-Dimensional. Experimental result was obtained from a portable laser digital vibrometer. While the 1-Dimensional value such as safety factor, deformation of hinges and stress analysis are obtained from finite elements simulation. Finally, the findings help to find the best design judging from the most travelled distance of the piezoelectric actuators. In addition, this paper would provide a clear picture the behavior of the CM embedded in the UVAM, which can provide good data and to improve the machining on reducing tool wear, and lower cutting force on the workpiece surface roughness.
Elemental investigation on Spanish dinosaur bones by x-ray fluorescence
NASA Astrophysics Data System (ADS)
Brunetti, Antonio; Piga, Giampaolo; Lasio, Barbara; Golosio, Bruno; Oliva, Piernicola; Stegel, Giovanni; Enzo, Stefano
2013-07-01
In this paper we examine the chemical composition results obtained on a collection of 18 dinosaur fossil bones from Spain studied using a portable x-ray fluorescence spectrometer together with a reverse Monte Carlo numerical technique of data analysis. This approach is applied to the hypothesis of arbitrarily rough surfaces in order to account for the influence of the surface state of specimens on the chemical content evaluation. It is confirmed that the chemical content of elements is essential for understanding the changes brought about by diagenetic and taphonomic processes. However, for precise knowledge of what changes fossil bones have undergone after animal life and burial, it is necessary to use a multi-technique approach making use of other instruments like x-ray diffraction in order to describe accurately the transformations undergone by the mineralogical and bioinorganic phases and the properties of specific molecular groups.
Uludağ, Yildiz; Piletsky, Sergey A; Turner, Anthony P F; Cooper, Matthew A
2007-11-01
Biomimetic recognition elements employed for the detection of analytes are commonly based on proteinaceous affibodies, immunoglobulins, single-chain and single-domain antibody fragments or aptamers. The alternative supra-molecular approach using a molecularly imprinted polymer now has proven utility in numerous applications ranging from liquid chromatography to bioassays. Despite inherent advantages compared with biochemical/biological recognition (which include robustness, storage endurance and lower costs) there are few contributions that describe quantitative analytical applications of molecularly imprinted polymers for relevant small molecular mass compounds in real-world samples. There is, however, significant literature describing the use of low-power, portable piezoelectric transducers to detect analytes in environmental monitoring and other application areas. Here we review the combination of molecularly imprinted polymers as recognition elements with piezoelectric biosensors for quantitative detection of small molecules. Analytes are classified by type and sample matrix presentation and various molecularly imprinted polymer synthetic fabrication strategies are also reviewed.
Integrated computer-aided design using minicomputers
NASA Technical Reports Server (NTRS)
Storaasli, O. O.
1980-01-01
Computer-Aided Design/Computer-Aided Manufacturing (CAD/CAM), a highly interactive software, has been implemented on minicomputers at the NASA Langley Research Center. CAD/CAM software integrates many formerly fragmented programs and procedures into one cohesive system; it also includes finite element modeling and analysis, and has been interfaced via a computer network to a relational data base management system and offline plotting devices on mainframe computers. The CAD/CAM software system requires interactive graphics terminals operating at a minimum of 4800 bits/sec transfer rate to a computer. The system is portable and introduces 'interactive graphics', which permits the creation and modification of models interactively. The CAD/CAM system has already produced designs for a large area space platform, a national transonic facility fan blade, and a laminar flow control wind tunnel model. Besides the design/drafting element analysis capability, CAD/CAM provides options to produce an automatic program tooling code to drive a numerically controlled (N/C) machine. Reductions in time for design, engineering, drawing, finite element modeling, and N/C machining will benefit productivity through reduced costs, fewer errors, and a wider range of configuration.
47 CFR 51.203 - Number portability.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 3 2010-10-01 2010-10-01 false Number portability. 51.203 Section 51.203 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) COMMON CARRIER SERVICES (CONTINUED) INTERCONNECTION Obligations of All Local Exchange Carriers § 51.203 Number portability. The rules governing number portability...
47 CFR 51.203 - Number portability.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 47 Telecommunication 3 2012-10-01 2012-10-01 false Number portability. 51.203 Section 51.203 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) COMMON CARRIER SERVICES (CONTINUED) INTERCONNECTION Obligations of All Local Exchange Carriers § 51.203 Number portability. The rules governing number portability...
47 CFR 51.203 - Number portability.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 47 Telecommunication 3 2014-10-01 2014-10-01 false Number portability. 51.203 Section 51.203 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) COMMON CARRIER SERVICES (CONTINUED) INTERCONNECTION Obligations of All Local Exchange Carriers § 51.203 Number portability. The rules governing number portability...
47 CFR 51.203 - Number portability.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 47 Telecommunication 3 2011-10-01 2011-10-01 false Number portability. 51.203 Section 51.203 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) COMMON CARRIER SERVICES (CONTINUED) INTERCONNECTION Obligations of All Local Exchange Carriers § 51.203 Number portability. The rules governing number portability...
47 CFR 51.203 - Number portability.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 47 Telecommunication 3 2013-10-01 2013-10-01 false Number portability. 51.203 Section 51.203 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) COMMON CARRIER SERVICES (CONTINUED) INTERCONNECTION Obligations of All Local Exchange Carriers § 51.203 Number portability. The rules governing number portability...
2011-12-01
Suitcase Portable Charger (SPC), Vehicle - Mounted Charger (VMC), Solar Portable Power System (SPACES) 15. NUMBER OF PAGES 77 16. PRICE CODE 17...battery (MCCOC, 2010): the Soldier Portable Charger (SPC), the Vehicle Mounted Charger (VMC), and the Solar Portable Alternative Communication Energy...Suitcase Portable Charger TO&E Table of Organization and Equipment UHF Ultra High Frequency VHF Very High Frequency VMC Vehicle Mounted
Operations manual for portable profiler : installing and using the portable profiler.
DOT National Transportation Integrated Search
2010-06-01
This manual is divided into two sections. The first is using the UTA-Profiler Program : with the portable profiler for generating surface profilers. The second is installing the : portable profiler module on a typical van or truck. The calibration an...
77 FR 4219 - FAA-Approved Portable Oxygen Concentrators; Technical Amendment
Federal Register 2010, 2011, 2012, 2013, 2014
2012-01-27
...-1343; Amdt. No. 121-358] FAA-Approved Portable Oxygen Concentrators; Technical Amendment AGENCY... amending regulations relating to operating rules for FAA approved portable oxygen concentrators (POC... Certain Portable Oxygen Concentrator Devices Onboard Aircraft'' (70 FR 40156). SFAR 106 permits passengers...
48 CFR 1837.170 - Pension portability.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 48 Federal Acquisition Regulations System 6 2010-10-01 2010-10-01 true Pension portability. 1837... ADMINISTRATION SPECIAL CATEGORIES OF CONTRACTING SERVICE CONTRACTING Service Contracts-General 1837.170 Pension portability. (a) It is NASA's policy not to require pension portability in service contracts. However, pension...
49 CFR 178.255 - Specification 60; steel portable tanks.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 49 Transportation 3 2014-10-01 2014-10-01 false Specification 60; steel portable tanks. 178.255 Section 178.255 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND... PACKAGINGS Specifications for Portable Tanks § 178.255 Specification 60; steel portable tanks. ...
49 CFR 178.255 - Specification 60; steel portable tanks.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 49 Transportation 3 2013-10-01 2013-10-01 false Specification 60; steel portable tanks. 178.255 Section 178.255 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND... PACKAGINGS Specifications for Portable Tanks § 178.255 Specification 60; steel portable tanks. ...
49 CFR 178.255 - Specification 60; steel portable tanks.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 3 2011-10-01 2011-10-01 false Specification 60; steel portable tanks. 178.255 Section 178.255 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND... PACKAGINGS Specifications for Portable Tanks § 178.255 Specification 60; steel portable tanks. ...
49 CFR 178.255 - Specification 60; steel portable tanks.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 49 Transportation 3 2012-10-01 2012-10-01 false Specification 60; steel portable tanks. 178.255 Section 178.255 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND... PACKAGINGS Specifications for Portable Tanks § 178.255 Specification 60; steel portable tanks. ...
NASA Astrophysics Data System (ADS)
Li, X.; Li, S. W.
2012-07-01
In this paper, an efficient global optimization algorithm in the field of artificial intelligence, named Particle Swarm Optimization (PSO), is introduced into close range photogrammetric data processing. PSO can be applied to obtain the approximate values of exterior orientation elements under the condition that multi-intersection photography and a small portable plane control frame are used. PSO, put forward by an American social psychologist J. Kennedy and an electrical engineer R.C. Eberhart, is a stochastic global optimization method based on swarm intelligence, which was inspired by social behavior of bird flocking or fish schooling. The strategy of obtaining the approximate values of exterior orientation elements using PSO is as follows: in terms of image coordinate observed values and space coordinates of few control points, the equations of calculating the image coordinate residual errors can be given. The sum of absolute value of each image coordinate is minimized to be the objective function. The difference between image coordinate observed value and the image coordinate computed through collinear condition equation is defined as the image coordinate residual error. Firstly a gross area of exterior orientation elements is given, and then the adjustment of other parameters is made to get the particles fly in the gross area. After iterative computation for certain times, the satisfied approximate values of exterior orientation elements are obtained. By doing so, the procedures like positioning and measuring space control points in close range photogrammetry can be avoided. Obviously, this method can improve the surveying efficiency greatly and at the same time can decrease the surveying cost. And during such a process, only one small portable control frame with a couple of control points is employed, and there are no strict requirements for the space distribution of control points. In order to verify the effectiveness of this algorithm, two experiments are carried out. In the first experiment, images of a standard grid board are taken according to multi-intersection photography using digital camera. Three points or six points which are located on the left-down corner of the standard grid are regarded as control points respectively, and the exterior orientation elements of each image are computed through PSO, and compared with these elements computed through bundle adjustment. In the second experiment, the exterior orientation elements obtained from the first experiment are used as approximate values in bundle adjustment and then the space coordinates of other grid points on the board can be computed. The coordinate difference of grid points between these computed space coordinates and their known coordinates can be used to compute the accuracy. The point accuracy computed in above experiments are ±0.76mm and ±0.43mm respectively. The above experiments prove the effectiveness of PSO used in close range photogrammetry to compute approximate values of exterior orientation elements, and the algorithm can meet the requirement of higher accuracy. In short, PSO can get better results in a faster, cheaper way compared with other surveying methods in close range photogrammetry.
Black manganese-rich crusts on a Gothic cathedral
NASA Astrophysics Data System (ADS)
Macholdt, Dorothea S.; Herrmann, Siegfried; Jochum, Klaus Peter; Kilcoyne, A. L. David; Laubscher, Thomas; Pfisterer, Jonas H. K.; Pöhlker, Christopher; Schwager, Beate; Weber, Bettina; Weigand, Markus; Domke, Katrin F.; Andreae, Meinrat O.
2017-12-01
Black manganese-rich crusts are found worldwide on the façades of historical buildings. In this study, they were studied exemplarily on the façade of the Freiburger Münster (Freiburg Minster), Germany, and measured in-situ by portable X-ray fluorescence (XRF). The XRF was calibrated to allow the conversion from apparent mass fractions to Mn surface density (Mn mass per area), to compensate for the fact that portable XRF mass fraction measurements from thin layers violate the assumption of a homogeneous measurement volume. Additionally, 200-nm femtosecond laser ablation-inductively coupled plasma-mass spectrometry (fs LA-ICP-MS) measurements, scanning transmission X-ray microscopy-near edge X-ray absorption fine structure spectroscopy (STXM-NEXAFS), Raman spectroscopy, and imaging by light microscopy were conducted to obtain further insight into the crust material, such as potential biogenic contributions, element distributions, trace element compositions, and organic functional groups. While black crusts of various types are present at many places on the minster's facade, crusts rich in Mn (with a Mn surface density >150 μg cm-2) are restricted to a maximum height of about 7 m. The only exceptions are those developed on the Renaissance-Vorhalle (Renaissance Portico) at a height of about 8 m. This part of the façade had been cleaned and treated with a silicon resin as recently as 2003. These crusts thus accumulated over a period of only 12 years. Yet, they are exceptionally Mn-rich with a surface density of 1200 μg cm-2, and therefore require an accumulation rate of about 100 μg cm-2 Mn per year. Trace element analyses support the theory that vehicle emissions are responsible for most of the Mn supply. Lead, barium, and zinc correlate with manganese, indicating that tire material, brake pads, and resuspended road dust are likely to be the element sources. Microscopic investigations show no organisms on or in the Mn-rich crusts. In contrast, Mn-free black crusts sampled at greater heights (>8 m) exhibited fungal and cyanobacterial encrustation. Carbon-rich spots were found by STXM-NEXAFS underneath one of the Mn-rich crusts. However, these carbon occurrences originate from soot and polycyclic aromatic hydrocarbons (PAHs) deposited on top of the crust, rather than from organisms responsible for the crust's formation, as shown by STXM-NEXAFS and Raman spectroscopic measurements. Our results suggest that the crusts develop abiogenically, with vehicle emissions as dominant element sources.
76 FR 31798 - Airworthiness Directives; L'Hotellier Portable Halon 1211 Fire Extinguishers
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-02
... Airworthiness Directives; L'Hotellier Portable Halon 1211 Fire Extinguishers AGENCY: Federal Aviation... directive (AD) for the specified fire extinguishers. This action requires replacing each unairworthy portable fire extinguisher with an airworthy portable fire extinguisher. This amendment is prompted by an...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-09-21
... Devices, Portable Music and Data Processing Devices, Computers, and Components Thereof; Institution of... communication devices, portable music and data processing devices, computers, and components thereof by reason... certain wireless communication devices, portable music and data processing devices, computers, and...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-10
..., Including Wireless Communication Devices, Portable Music and Data Processing Devices, and Tablet Computers... importing wireless communication devices, portable music and data processing devices, and tablet computers... certain electronic devices, including wireless communication devices, portable music and data processing...
49 CFR 178.255 - Specification 60; steel portable tanks.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 2 2010-10-01 2010-10-01 false Specification 60; steel portable tanks. 178.255 Section 178.255 Transportation Other Regulations Relating to Transportation PIPELINE AND HAZARDOUS... FOR PACKAGINGS Specifications for Portable Tanks § 178.255 Specification 60; steel portable tanks. ...
Wang, Sihong; Lin, Long; Wang, Zhong Lin
2012-12-12
Harvesting energy from our living environment is an effective approach for sustainable, maintenance-free, and green power source for wireless, portable, or implanted electronics. Mechanical energy scavenging based on triboelectric effect has been proven to be simple, cost-effective, and robust. However, its output is still insufficient for sustainably driving electronic devices/systems. Here, we demonstrated a rationally designed arch-shaped triboelectric nanogenerator (TENG) by utilizing the contact electrification between a polymer thin film and a metal thin foil. The working mechanism of the TENG was studied by finite element simulation. The output voltage, current density, and energy volume density reached 230 V, 15.5 μA/cm(2), and 128 mW/cm(3), respectively, and an energy conversion efficiency as high as 10-39% has been demonstrated. The TENG was systematically studied and demonstrated as a sustainable power source that can not only drive instantaneous operation of light-emitting diodes (LEDs) but also charge a lithium ion battery as a regulated power module for powering a wireless sensor system and a commercial cell phone, which is the first demonstration of the nanogenerator for driving personal mobile electronics, opening the chapter of impacting general people's life by nanogenerators.
A portable meter for measuring low frequency currents in the human body.
Niple, J C; Daigle, J P; Zaffanella, L E; Sullivan, T; Kavet, R
2004-07-01
A portable meter has been developed for measuring low frequency currents that flow in the human body. Although the present version of the meter was specifically designed to measure 50/60 Hz "contact currents," the principles involved can be used with other low frequency body currents. Contact currents flow when the human body provides a conductive path between objects in the environment with different electrical potentials. The range of currents the meter detects is approximately 0.4-800 microA. This provides measurements of currents from the threshold of human perception (approximately 500 microA(RMS)) down to single microampere levels. The meter has a unique design, which utilizes the human subject's body impedance as the sensing element. Some of the advantages of this approach are high sensitivity, the ability to measure current flow in the majority of the body, and relative insensitivity to the current path connection points. Current measurement accuracy varies with the accuracy of the body impedance (resistance) measurement and different techniques can be used to obtain a desired level of accuracy. Techniques are available to achieve an estimated +/-20% accuracy. Copyright 2004 Wiley-Liss, Inc.
Spatial mapping and analysis of aerosols during a forest fire using computational mobile microscopy
NASA Astrophysics Data System (ADS)
Wu, Yichen; Shiledar, Ashutosh; Luo, Yi; Wong, Jeffrey; Chen, Cheng; Bai, Bijie; Zhang, Yibo; Tamamitsu, Miu; Ozcan, Aydogan
2018-02-01
Forest fires are a major source of particulate matter (PM) air pollution on a global scale. The composition and impact of PM are typically studied using only laboratory instruments and extrapolated to real fire events owing to a lack of analytical techniques suitable for field-settings. To address this and similar field test challenges, we developed a mobilemicroscopy- and machine-learning-based air quality monitoring platform called c-Air, which can perform air sampling and microscopic analysis of aerosols in an integrated portable device. We tested its performance for PM sizing and morphological analysis during a recent forest fire event in La Tuna Canyon Park by spatially mapping the PM. The result shows that with decreasing distance to the fire site, the PM concentration increases dramatically, especially for particles smaller than 2 µm. Image analysis from the c-Air portable device also shows that the increased PM is comparatively strongly absorbing and asymmetric, with an aspect ratio of 0.5-0.7. These PM features indicate that a major portion of the PM may be open-flame-combustion-generated element carbon soot-type particles. This initial small-scale experiment shows that c-Air has some potential for forest fire monitoring.
The Software Element of the NASA Portable Electronic Device Radiated Emissions Investigation
NASA Technical Reports Server (NTRS)
Koppen, Sandra V.; Williams, Reuben A. (Technical Monitor)
2002-01-01
NASA Langley Research Center's (LaRC) High Intensity Radiated Fields Laboratory (HIRF Lab) recently conducted a series of electromagnetic radiated emissions tests under a cooperative agreement with Delta Airlines and an interagency agreement with the FAA. The frequency spectrum environment at a commercial airport was measured on location. The environment survey provides a comprehensive picture of the complex nature of the electromagnetic environment present in those areas outside the aircraft. In addition, radiated emissions tests were conducted on portable electronic devices (PEDs) that may be brought onboard aircraft. These tests were performed in both semi-anechoic and reverberation chambers located in the HIRF Lab. The PEDs included cell phones, laptop computers, electronic toys, and family radio systems. The data generated during the tests are intended to support the research on the effect of radiated emissions from wireless devices on aircraft systems. Both tests systems relied on customized control and data reduction software to provide test and instrument control, data acquisition, a user interface, real time data reduction, and data analysis. The software executed on PC's running MS Windows 98 and 2000, and used Agilent Pro Visual Engineering Environment (VEE) development software, Common Object Model (COM) technology, and MS Excel.
Semi-Quantitative Evaluation of Secondary Carbonates via Portable X-ray Fluorescence Spectrometry
NASA Astrophysics Data System (ADS)
Chakraborty, Somsubhra; Weindorf, David; Weindorf, Camille; Duda, Bogdan; Pennington, Sarah; Ortiz, Rebekah
2017-04-01
Secondary calcium carbonate commonly occurs in subsoils of semi-arid soils worldwide. In US Soil Taxonomy, such horizons are frequently described as Bk, Bkk, Bkm, Bkkm, or Ck horizons at variable stages of development. Specifically, the Soil Survey Staff uses a qualitative scale of one through six to indicate differential developmental stages. However, considerable disagreement exists even among experienced soil scientists. Evaluating 75 soil samples from across four US states, a portable X-ray fluorescence (PXRF) spectrometer was used to quantify the total soil Ca content and compare it to average developmental stage scores as determined by a panel of Soil Survey Staff personnel. Samples were evaluated both as intact aggregates as well as ground (<2 mm), homogenized powders. PXRF readings of total soil Ca concentration steadily increased under both conditions as developmental stage progressed. However, minimal difference was observed between stage five and six carbonate accumulation. Stage three showed the widest variability in total soil Ca. Given than PXRF cannot distinguish between primary and secondary CaCO3 in soils, interpretation by the analyst remains essential. Nonetheless, PXRF provides an important tool for assessing carbonate laden subsoils providing elemental differentiation beyond that perceived by the human eye.
Dos Reis, Laura L; Tuttle, R Michael; Alon, Eran; Bergman, Donald A; Bernet, Victor; Brett, Elise M; Cobin, Rhoda; Doherty, Gerard; Harris, Jeffrey R; Klopper, Joshua; Lee, Stephanie L; Lupo, Mark; Milas, Mira; Machac, Josef; Mechanick, Jeffrey I; Orloff, Lisa; Randolph, Gregory; Ross, Douglas S; Smallridge, Robert C; Terris, David James; Tufano, Ralph P; Mehra, Saral; Scherl, Sophie; Clain, Jason B; Urken, Mark L
2014-10-01
Appropriate management of well-differentiated thyroid cancer requires treating clinicians to have access to critical elements of the patient's presentation, surgical management, postoperative course, and pathologic assessment. Electronic health records (EHRs) provide an effective method for the storage and transmission of patient information, although most commercially available EHRs are not intended to be disease-specific. In addition, there are significant challenges for the sharing of relevant clinical information when providers involved in the care of a patient with thyroid cancer are not connected by a common EHR. In 2012, the American Thyroid Association (ATA) defined the critical elements for optimal interclinician communication in a position paper entitled, "The Essential Elements of Interdisciplinary Communication of Perioperative Information for Patients Undergoing Thyroid Cancer Surgery." We present a field-by-field comparison of the ATA's essential elements as applied to three contemporary electronic reporting systems: the Thyroid Surgery e-Form from Memorial Sloan-Kettering Cancer Center (MSKCC), the Alberta WebSMR from the University of Calgary, and the Thyroid Cancer Care Collaborative (TCCC). The MSKCC e-form fulfills 21 of 32 intraoperative fields and includes an additional 14 fields not specifically mentioned in the ATA's report. The Alberta WebSMR fulfills 45 of 82 preoperative and intraoperative fields outlined by the ATA and includes 13 additional fields. The TCCC fulfills 117 of 120 fields outlined by the ATA and includes 23 additional fields. Effective management of thyroid cancer is a highly collaborative, multidisciplinary effort. The patient information that factors into clinical decisions about thyroid cancer is complex. For these reasons, EHRs are particularly favorable for the management of patients with thyroid cancer. The MSKCC Thyroid Surgery e-Form, the Alberta WebSMR, and the TCCC each meet all of the general recommendations for effective reporting of the specific domains that they cover in the management of thyroid cancer, as recommended by the ATA. However, the TCCC format is the most comprehensive. The TCCC is a new Web-based disease-specific database to enhance communication of patient information between clinicians in a Health Insurance Portability and Accountability Act (HIPAA)-compliant manner. We believe the easy-to-use TCCC format will enhance clinician communication while providing portability of thyroid cancer information for patients.
New conceptual design of portable bamboo bridge for emergency purposes
NASA Astrophysics Data System (ADS)
Musthaffa, A. A.; Nor, N. M.; Yusof, M. A.; Yuhazri, M. Y.
2018-02-01
Portable bridges serve as routes for troops during the military operations and the disaster relief operation. Nowadays, bamboo has been regarded as one of the alternative construction materials for building and bridge structures. This paper presents the conceptual design of the portable bridge. Several types of portable bridges and bamboo bridges are reviewed in the current work. The characteristics, capability and method of construction of each bridge are discussed. Finally, the conceptual of the portable bamboo bridge for emergency purposes is presented. The idea of producing portable bridge is proposed in the current work as it is crucial for providing route for communities affected by natural disasters.
[Advances of portable electrocardiogram monitor design].
Ding, Shenping; Wang, Yinghai; Wu, Weirong; Deng, Lingli; Lu, Jidong
2014-06-01
Portable electrocardiogram monitor is an important equipment in the clinical diagnosis of cardiovascular diseases due to its portable, real-time features. It has a broad application and development prospects in China. In the present review, previous researches on the portable electrocardiogram monitors have been arranged, analyzed and summarized. According to the characteristics of the electrocardiogram (ECG), this paper discusses the ergonomic design of the portable electrocardiogram monitor, including hardware and software. The circuit components and software modules were parsed from the ECG features and system functions. Finally, the development trend and reference are provided for the portable electrocardiogram monitors and for the subsequent research and product design.
Huang, Lu-Chou; Chu, Huei-Chung; Lien, Chung-Yueh; Hsiao, Chia-Hung; Kao, Tsair
2009-09-01
As patients face the possibility of copying and keeping their electronic health records (EHRs) through portable storage media, they will encounter new risks to the protection of their private information. In this study, we propose a method to preserve the privacy and security of patients' portable medical records in portable storage media to avoid any inappropriate or unintentional disclosure. Following HIPAA guidelines, the method is designed to protect, recover and verify patient's identifiers in portable EHRs. The results of this study show that our methods are effective in ensuring both information security and privacy preservation for patients through portable storage medium.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-04-29
..., Including Mobile Phones, Mobile Tablets, Portable Music Players, and Computers, and Components Thereof... certain electronic devices, including mobile phones, mobile tablets, portable music players, and computers... mobile phones, mobile tablets, portable music players, and computers, and components thereof that...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-01
..., Including Wireless Communication Devices, Portable Music and Data Processing Devices, and Tablet Computers... electronic devices, including wireless communication devices, portable music and data processing devices, and... electronic devices, including wireless communication devices, portable music and data processing devices, and...
21 CFR 868.5440 - Portable oxygen generator.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Portable oxygen generator. 868.5440 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5440 Portable oxygen generator. (a) Identification. A portable oxygen generator is a device that is intended to release oxygen for respiratory...
21 CFR 868.5440 - Portable oxygen generator.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Portable oxygen generator. 868.5440 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5440 Portable oxygen generator. (a) Identification. A portable oxygen generator is a device that is intended to release oxygen for respiratory...
21 CFR 868.5440 - Portable oxygen generator.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Portable oxygen generator. 868.5440 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5440 Portable oxygen generator. (a) Identification. A portable oxygen generator is a device that is intended to release oxygen for respiratory...
21 CFR 868.5440 - Portable oxygen generator.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Portable oxygen generator. 868.5440 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5440 Portable oxygen generator. (a) Identification. A portable oxygen generator is a device that is intended to release oxygen for respiratory...
21 CFR 868.5440 - Portable oxygen generator.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Portable oxygen generator. 868.5440 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5440 Portable oxygen generator. (a) Identification. A portable oxygen generator is a device that is intended to release oxygen for respiratory...
Lee, Hyeongyu; Choi, Yosoon; Suh, Jangwon; Lee, Seung-Ho
2016-01-01
Understanding spatial variation of potentially toxic trace elements (PTEs) in soil is necessary to identify the proper measures for preventing soil contamination at both operating and abandoned mining areas. Many studies have been conducted worldwide to explore the spatial variation of PTEs and to create soil contamination maps using geostatistical methods. However, they generally depend only on inductively coupled plasma atomic emission spectrometry (ICP–AES) analysis data, therefore such studies are limited by insufficient input data owing to the disadvantages of ICP–AES analysis such as its costly operation and lengthy period required for analysis. To overcome this limitation, this study used both ICP–AES and portable X-ray fluorescence (PXRF) analysis data, with relatively low accuracy, for mapping copper and lead concentrations at a section of the Busan abandoned mine in Korea and compared the prediction performances of four different approaches: the application of ordinary kriging to ICP–AES analysis data, PXRF analysis data, both ICP–AES and transformed PXRF analysis data by considering the correlation between the ICP–AES and PXRF analysis data, and co-kriging to both the ICP–AES (primary variable) and PXRF analysis data (secondary variable). Their results were compared using an independent validation data set. The results obtained in this case study showed that the application of ordinary kriging to both ICP–AES and transformed PXRF analysis data is the most accurate approach when considers the spatial distribution of copper and lead contaminants in the soil and the estimation errors at 11 sampling points for validation. Therefore, when generating soil contamination maps for an abandoned mine, it is beneficial to use the proposed approach that incorporates the advantageous aspects of both ICP–AES and PXRF analysis data. PMID:27043594
Lee, Hyeongyu; Choi, Yosoon; Suh, Jangwon; Lee, Seung-Ho
2016-03-30
Understanding spatial variation of potentially toxic trace elements (PTEs) in soil is necessary to identify the proper measures for preventing soil contamination at both operating and abandoned mining areas. Many studies have been conducted worldwide to explore the spatial variation of PTEs and to create soil contamination maps using geostatistical methods. However, they generally depend only on inductively coupled plasma atomic emission spectrometry (ICP-AES) analysis data, therefore such studies are limited by insufficient input data owing to the disadvantages of ICP-AES analysis such as its costly operation and lengthy period required for analysis. To overcome this limitation, this study used both ICP-AES and portable X-ray fluorescence (PXRF) analysis data, with relatively low accuracy, for mapping copper and lead concentrations at a section of the Busan abandoned mine in Korea and compared the prediction performances of four different approaches: the application of ordinary kriging to ICP-AES analysis data, PXRF analysis data, both ICP-AES and transformed PXRF analysis data by considering the correlation between the ICP-AES and PXRF analysis data, and co-kriging to both the ICP-AES (primary variable) and PXRF analysis data (secondary variable). Their results were compared using an independent validation data set. The results obtained in this case study showed that the application of ordinary kriging to both ICP-AES and transformed PXRF analysis data is the most accurate approach when considers the spatial distribution of copper and lead contaminants in the soil and the estimation errors at 11 sampling points for validation. Therefore, when generating soil contamination maps for an abandoned mine, it is beneficial to use the proposed approach that incorporates the advantageous aspects of both ICP-AES and PXRF analysis data.
Renner, Lars D.; Zan, Jindong; Hu, Linda I.; Martinez, Manuel; Resto, Pedro J.; Siegel, Adam C.; Torres, Clint; Hall, Sara B.; Slezak, Tom R.
2016-01-01
ABSTRACT An estimated 1.5 billion microbial infections occur globally each year and result in ∼4.6 million deaths. A technology gap associated with commercially available diagnostic tests in remote and underdeveloped regions prevents timely pathogen identification for effective antibiotic chemotherapies for infected patients. The result is a trial-and-error approach that is limited in effectiveness, increases risk for patients while contributing to antimicrobial drug resistance, and reduces the lifetime of antibiotics. This paper addresses this important diagnostic technology gap by describing a low-cost, portable, rapid, and easy-to-use microfluidic cartridge-based system for detecting the ESKAPE (Enterococcus faecium, Staphylococcus aureus, Klebsiella pneumoniae, Acinetobacter baumannii, Pseudomonas aeruginosa, and Enterobacter spp.) bacterial pathogens that are most commonly associated with antibiotic resistance. The point-of-care molecular diagnostic system consists of a vacuum-degassed microfluidic cartridge preloaded with lyophilized recombinase polymerase amplification (RPA) assays and a small portable battery-powered electronic incubator/reader. The isothermal RPA assays detect the targeted ESKAPE pathogens with high sensitivity (e.g., a limit of detection of ∼10 nucleic acid molecules) that is comparable to that of current PCR-based assays, and they offer advantages in power consumption, engineering, and robustness, which are three critical elements required for the point-of-care setting. IMPORTANCE This paper describes a portable system for rapidly identifying bacteria in resource-limited environments; we highlight the capabilities of the technology by detecting different pathogens within the ESKAPE collection, which cause nosocomial infections. The system is designed around isothermal DNA-based assays housed within an autonomous plastic cartridge that are designed with the end user in mind, who may have limited technological training. Displaying excellent sensitivity and specificity, the assay systems that we demonstrate may enable future diagnoses of bacterial infection to guide the development of effective chemotherapies and may have a role in areas beyond health where rapid detection is valuable, including in industrial processing and manufacturing, food security, agriculture, and water quality testing. PMID:27986722
Renner, Lars D; Zan, Jindong; Hu, Linda I; Martinez, Manuel; Resto, Pedro J; Siegel, Adam C; Torres, Clint; Hall, Sara B; Slezak, Tom R; Nguyen, Tuan H; Weibel, Douglas B
2017-02-15
An estimated 1.5 billion microbial infections occur globally each year and result in ∼4.6 million deaths. A technology gap associated with commercially available diagnostic tests in remote and underdeveloped regions prevents timely pathogen identification for effective antibiotic chemotherapies for infected patients. The result is a trial-and-error approach that is limited in effectiveness, increases risk for patients while contributing to antimicrobial drug resistance, and reduces the lifetime of antibiotics. This paper addresses this important diagnostic technology gap by describing a low-cost, portable, rapid, and easy-to-use microfluidic cartridge-based system for detecting the ESKAPE (Enterococcus faecium, Staphylococcus aureus, Klebsiella pneumoniae, Acinetobacter baumannii, Pseudomonas aeruginosa, and Enterobacter spp.) bacterial pathogens that are most commonly associated with antibiotic resistance. The point-of-care molecular diagnostic system consists of a vacuum-degassed microfluidic cartridge preloaded with lyophilized recombinase polymerase amplification (RPA) assays and a small portable battery-powered electronic incubator/reader. The isothermal RPA assays detect the targeted ESKAPE pathogens with high sensitivity (e.g., a limit of detection of ∼10 nucleic acid molecules) that is comparable to that of current PCR-based assays, and they offer advantages in power consumption, engineering, and robustness, which are three critical elements required for the point-of-care setting. This paper describes a portable system for rapidly identifying bacteria in resource-limited environments; we highlight the capabilities of the technology by detecting different pathogens within the ESKAPE collection, which cause nosocomial infections. The system is designed around isothermal DNA-based assays housed within an autonomous plastic cartridge that are designed with the end user in mind, who may have limited technological training. Displaying excellent sensitivity and specificity, the assay systems that we demonstrate may enable future diagnoses of bacterial infection to guide the development of effective chemotherapies and may have a role in areas beyond health where rapid detection is valuable, including in industrial processing and manufacturing, food security, agriculture, and water quality testing. Copyright © 2017 Renner et al.
NASA Astrophysics Data System (ADS)
Hermoso, J. L. Navarro; Espinosa-Rueda, Guillermo; Martinez, Noelia; Heras, Carlos; Osta, Marta
2016-05-01
The performance of parabolic trough (PT) receiver tubes (RT) has a direct impact on Solar Thermal Energy (STE) plant production. As a result, one major need of operation and maintenance (O&M) in STE plants is to monitor the state of the receiver tube as a key element in the solar field. However the lack of specific devices so far has limited the proper evaluation of operating receiver tubés thermal performance. As a consequence non-accurate approximations have been accepted until now using infrared thermal images of the glass outer tube. In order to fulfill this need, Abengoa has developed a unique portable device for evaluating the thermal performance and vacuum state of parabolic trough receiver tubes placed in the field. The novel device described in this paper, simultaneously provides the temperature of both the inner steel tube and the outer glass tube enabling a check on manufacturers specifications. The on-field evaluation of any receiver tube at any operating temperature has become possible thanks to this new measuring device. The features and usability of this new measurement system as a workable portable device in operating solar fields provide a very useful tool for all companies in the sector contributing to technology progress. The originality of the device, patent pending P201431969, is not limited to the CSP sector, also having scientific significance in the general measuring instruments field. This paper presents the work carried out to develop and validate the device, also detailing its functioning properties and including the excellent results obtained in the laboratory to determine its accuracy and standard deviation. This information was validated with data collected by O&M teams using this instrument in a commercial CSP plant. The relevance of the device has been evidenced by evaluating a wide sample of RT and the results are discussed in this paper. Finally, all the on field collected data is used to demonstrate the high impact that using this unique portable device will have on a parabolic trough solar power plant.
29 CFR 1910.25 - Portable wood ladders.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 29 Labor 5 2013-07-01 2013-07-01 false Portable wood ladders. 1910.25 Section 1910.25 Labor... OCCUPATIONAL SAFETY AND HEALTH STANDARDS Walking-Working Surfaces § 1910.25 Portable wood ladders. (a... for the construction, care, and use of the common types of portable wood ladders, in order to insure...
29 CFR 1910.25 - Portable wood ladders.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 29 Labor 5 2014-07-01 2014-07-01 false Portable wood ladders. 1910.25 Section 1910.25 Labor... OCCUPATIONAL SAFETY AND HEALTH STANDARDS Walking-Working Surfaces § 1910.25 Portable wood ladders. (a... for the construction, care, and use of the common types of portable wood ladders, in order to insure...
46 CFR 98.33-5 - Portable tanks authorized.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false Portable tanks authorized. 98.33-5 Section 98.33-5... CONSTRUCTION, ARRANGEMENT, AND OTHER PROVISIONS FOR CERTAIN DANGEROUS CARGOES IN BULK Portable Tanks for Certain Grade E Combustible Liquids and Other Regulated Materials § 98.33-5 Portable tanks authorized. The...
46 CFR 98.33-5 - Portable tanks authorized.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Portable tanks authorized. 98.33-5 Section 98.33-5... CONSTRUCTION, ARRANGEMENT, AND OTHER PROVISIONS FOR CERTAIN DANGEROUS CARGOES IN BULK Portable Tanks for Certain Grade E Combustible Liquids and Other Regulated Materials § 98.33-5 Portable tanks authorized. The...
49 CFR 172.326 - Portable tanks.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 49 Transportation 2 2012-10-01 2012-10-01 false Portable tanks. 172.326 Section 172.326... SECURITY PLANS Marking § 172.326 Portable tanks. (a) Shipping name. No person may offer for transportation or transport a portable tank containing a hazardous material unless it is legibly marked on two...
49 CFR 172.326 - Portable tanks.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 49 Transportation 2 2013-10-01 2013-10-01 false Portable tanks. 172.326 Section 172.326... SECURITY PLANS Marking § 172.326 Portable tanks. (a) Shipping name. No person may offer for transportation or transport a portable tank containing a hazardous material unless it is legibly marked on two...
49 CFR 172.326 - Portable tanks.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 49 Transportation 2 2014-10-01 2014-10-01 false Portable tanks. 172.326 Section 172.326... SECURITY PLANS Marking § 172.326 Portable tanks. (a) Shipping name. No person may offer for transportation or transport a portable tank containing a hazardous material unless it is legibly marked on two...
49 CFR 172.326 - Portable tanks.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 2 2011-10-01 2011-10-01 false Portable tanks. 172.326 Section 172.326... SECURITY PLANS Marking § 172.326 Portable tanks. (a) Shipping name. No person may offer for transportation or transport a portable tank containing a hazardous material unless it is legibly marked on two...
78 FR 33393 - Petition Requesting a Ban or Standard on Adult Portable Bed Rails
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-04
... Standard on Adult Portable Bed Rails AGENCY: Consumer Product Safety Commission. ACTION: Notice. SUMMARY... adult portable bed rails pose an unreasonable risk of injury and initiate related rulemaking under... that adult portable bed rails pose an unreasonable risk of injury and initiate related rulemaking under...
21 CFR 868.6250 - Portable air compressor.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Portable air compressor. 868.6250 Section 868.6250...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Miscellaneous § 868.6250 Portable air compressor. (a) Identification. A portable air compressor is a device intended to provide compressed air for medical purposes, e...
47 CFR 73.1530 - Portable test stations [Definition].
Code of Federal Regulations, 2014 CFR
2014-10-01
... 47 Telecommunication 4 2014-10-01 2014-10-01 false Portable test stations [Definition]. 73.1530 Section 73.1530 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES RADIO BROADCAST SERVICES Rules Applicable to All Broadcast Stations § 73.1530 Portable test stations [Definition]. A portable test station is one...
47 CFR 73.1530 - Portable test stations [Definition].
Code of Federal Regulations, 2012 CFR
2012-10-01
... 47 Telecommunication 4 2012-10-01 2012-10-01 false Portable test stations [Definition]. 73.1530 Section 73.1530 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES RADIO BROADCAST SERVICES Rules Applicable to All Broadcast Stations § 73.1530 Portable test stations [Definition]. A portable test station is one...
30 CFR 47.44 - Temporary, portable containers.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Temporary, portable containers. 47.44 Section... TRAINING HAZARD COMMUNICATION (HazCom) Container Labels and Other Forms of Warning § 47.44 Temporary, portable containers. (a) The operator does not have to label a temporary, portable container if he or she...
21 CFR 868.6250 - Portable air compressor.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Portable air compressor. 868.6250 Section 868.6250...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Miscellaneous § 868.6250 Portable air compressor. (a) Identification. A portable air compressor is a device intended to provide compressed air for medical purposes, e...
21 CFR 868.6250 - Portable air compressor.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Portable air compressor. 868.6250 Section 868.6250...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Miscellaneous § 868.6250 Portable air compressor. (a) Identification. A portable air compressor is a device intended to provide compressed air for medical purposes, e...
Code of Federal Regulations, 2012 CFR
2012-10-01
... Recovery of carrier-specific costs directly related to providing long-term number portability. (a... related to providing long-term number portability. 52.33 Section 52.33 Telecommunication FEDERAL... long-term number portability by establishing in tariffs filed with the Federal Communications...
Code of Federal Regulations, 2013 CFR
2013-10-01
... Recovery of carrier-specific costs directly related to providing long-term number portability. (a... related to providing long-term number portability. 52.33 Section 52.33 Telecommunication FEDERAL... long-term number portability by establishing in tariffs filed with the Federal Communications...
Code of Federal Regulations, 2014 CFR
2014-10-01
... Recovery of carrier-specific costs directly related to providing long-term number portability. (a... related to providing long-term number portability. 52.33 Section 52.33 Telecommunication FEDERAL... long-term number portability by establishing in tariffs filed with the Federal Communications...
Code of Federal Regulations, 2011 CFR
2011-10-01
... Recovery of carrier-specific costs directly related to providing long-term number portability. (a... related to providing long-term number portability. 52.33 Section 52.33 Telecommunication FEDERAL... long-term number portability by establishing in tariffs filed with the Federal Communications...
29 CFR 1915.132 - Portable electric tools.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 29 Labor 7 2013-07-01 2013-07-01 false Portable electric tools. 1915.132 Section 1915.132 Labor... § 1915.132 Portable electric tools. The provisions of this section shall apply to ship repairing... frames of portable electric tools and appliances, except double insulated tools approved by Underwriters...
29 CFR 1915.132 - Portable electric tools.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 29 Labor 7 2012-07-01 2012-07-01 false Portable electric tools. 1915.132 Section 1915.132 Labor... § 1915.132 Portable electric tools. The provisions of this section shall apply to ship repairing... frames of portable electric tools and appliances, except double insulated tools approved by Underwriters...
29 CFR 1915.132 - Portable electric tools.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 29 Labor 7 2014-07-01 2014-07-01 false Portable electric tools. 1915.132 Section 1915.132 Labor... § 1915.132 Portable electric tools. The provisions of this section shall apply to ship repairing... frames of portable electric tools and appliances, except double insulated tools approved by Underwriters...
29 CFR 1915.132 - Portable electric tools.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 29 Labor 7 2011-07-01 2011-07-01 false Portable electric tools. 1915.132 Section 1915.132 Labor... § 1915.132 Portable electric tools. The provisions of this section shall apply to ship repairing... frames of portable electric tools and appliances, except double insulated tools approved by Underwriters...
29 CFR 1915.132 - Portable electric tools.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 29 Labor 7 2010-07-01 2010-07-01 false Portable electric tools. 1915.132 Section 1915.132 Labor... § 1915.132 Portable electric tools. The provisions of this section shall apply to ship repairing... frames of portable electric tools and appliances, except double insulated tools approved by Underwriters...
47 CFR 80.53 - Application for a portable ship station license.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 5 2010-10-01 2010-10-01 false Application for a portable ship station license... a portable ship station license. The Commission may grant a license permitting operation of a portable ship station aboard different vessels of the United States. [63 FR 68956, Dec. 14, 1998] ...
47 CFR 80.53 - Application for a portable ship station license.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 47 Telecommunication 5 2011-10-01 2011-10-01 false Application for a portable ship station license... a portable ship station license. The Commission may grant a license permitting operation of a portable ship station aboard different vessels of the United States. [63 FR 68956, Dec. 14, 1998] ...
47 CFR 80.53 - Application for a portable ship station license.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 47 Telecommunication 5 2013-10-01 2013-10-01 false Application for a portable ship station license... a portable ship station license. The Commission may grant a license permitting operation of a portable ship station aboard different vessels of the United States. [63 FR 68956, Dec. 14, 1998] ...
47 CFR 80.53 - Application for a portable ship station license.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 47 Telecommunication 5 2012-10-01 2012-10-01 false Application for a portable ship station license... a portable ship station license. The Commission may grant a license permitting operation of a portable ship station aboard different vessels of the United States. [63 FR 68956, Dec. 14, 1998] ...
47 CFR 80.53 - Application for a portable ship station license.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 47 Telecommunication 5 2014-10-01 2014-10-01 false Application for a portable ship station license... a portable ship station license. The Commission may grant a license permitting operation of a portable ship station aboard different vessels of the United States. [63 FR 68956, Dec. 14, 1998] ...
Enabling Logistics With Portable and Wireless Technology Study. Volume 1
2004-08-06
Project”, Ubiquitous Computing Group Microsoft Research, 2001. 102 Enabling Logistics with Portable and Wireless Technology Study ...Enabling Logistics with Portable and Wireless Technology Study Final Report FINAL REPORT...Volume I) Enabling Logistics with Portable and Wireless Technology Study AUTHORS School of Industrial Engineering Dr. Soundar Kumara
14 CFR 135.144 - Portable electronic devices.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 14 Aeronautics and Space 3 2014-01-01 2014-01-01 false Portable electronic devices. 135.144... Equipment § 135.144 Portable electronic devices. (a) Except as provided in paragraph (b) of this section, no... portable electronic device on any of the following U.S.-registered civil aircraft operating under this part...
14 CFR 135.144 - Portable electronic devices.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Portable electronic devices. 135.144... Equipment § 135.144 Portable electronic devices. (a) Except as provided in paragraph (b) of this section, no... portable electronic device on any of the following U.S.-registered civil aircraft operating under this part...
14 CFR 125.204 - Portable electronic devices.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Portable electronic devices. 125.204... Equipment Requirements § 125.204 Portable electronic devices. (a) Except as provided in paragraph (b) of... operation of, any portable electronic device on any U.S.-registered civil aircraft operating under this part...
14 CFR 125.204 - Portable electronic devices.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 3 2011-01-01 2011-01-01 false Portable electronic devices. 125.204... Equipment Requirements § 125.204 Portable electronic devices. (a) Except as provided in paragraph (b) of... operation of, any portable electronic device on any U.S.-registered civil aircraft operating under this part...
14 CFR 125.204 - Portable electronic devices.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 14 Aeronautics and Space 3 2013-01-01 2013-01-01 false Portable electronic devices. 125.204... Equipment Requirements § 125.204 Portable electronic devices. (a) Except as provided in paragraph (b) of... operation of, any portable electronic device on any U.S.-registered civil aircraft operating under this part...
14 CFR 125.204 - Portable electronic devices.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 14 Aeronautics and Space 3 2014-01-01 2014-01-01 false Portable electronic devices. 125.204... Equipment Requirements § 125.204 Portable electronic devices. (a) Except as provided in paragraph (b) of... operation of, any portable electronic device on any U.S.-registered civil aircraft operating under this part...
14 CFR 135.144 - Portable electronic devices.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 3 2011-01-01 2011-01-01 false Portable electronic devices. 135.144... Equipment § 135.144 Portable electronic devices. (a) Except as provided in paragraph (b) of this section, no... portable electronic device on any of the following U.S.-registered civil aircraft operating under this part...
14 CFR 135.144 - Portable electronic devices.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 14 Aeronautics and Space 3 2012-01-01 2012-01-01 false Portable electronic devices. 135.144... Equipment § 135.144 Portable electronic devices. (a) Except as provided in paragraph (b) of this section, no... portable electronic device on any of the following U.S.-registered civil aircraft operating under this part...
14 CFR 125.204 - Portable electronic devices.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 14 Aeronautics and Space 3 2012-01-01 2012-01-01 false Portable electronic devices. 125.204... Equipment Requirements § 125.204 Portable electronic devices. (a) Except as provided in paragraph (b) of... operation of, any portable electronic device on any U.S.-registered civil aircraft operating under this part...
14 CFR 135.144 - Portable electronic devices.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 14 Aeronautics and Space 3 2013-01-01 2013-01-01 false Portable electronic devices. 135.144... Equipment § 135.144 Portable electronic devices. (a) Except as provided in paragraph (b) of this section, no... portable electronic device on any of the following U.S.-registered civil aircraft operating under this part...
Code of Federal Regulations, 2014 CFR
2014-10-01
... channels on which the Mode I device, but not the fixed device, may operate. (d) Geo-location capability.../portable device. A personal/portable TVBD that does not use an internal geo-location capability and access.../portable device. A personal/portable TVBD that uses an internal geo-location capability and access to a TV...
33 CFR 127.203 - Portable gas detectors.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 33 Navigation and Navigable Waters 2 2012-07-01 2012-07-01 false Portable gas detectors. 127.203... Waterfront Facilities Handling Liquefied Natural Gas Equipment § 127.203 Portable gas detectors. The marine transfer area for LNG must have at least two portable gas detectors capable of measuring 0-100% of the...
33 CFR 127.203 - Portable gas detectors.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false Portable gas detectors. 127.203... Waterfront Facilities Handling Liquefied Natural Gas Equipment § 127.203 Portable gas detectors. The marine transfer area for LNG must have at least two portable gas detectors capable of measuring 0-100% of the...
33 CFR 127.203 - Portable gas detectors.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 33 Navigation and Navigable Waters 2 2014-07-01 2014-07-01 false Portable gas detectors. 127.203... Waterfront Facilities Handling Liquefied Natural Gas Equipment § 127.203 Portable gas detectors. The marine transfer area for LNG must have at least two portable gas detectors capable of measuring 0-100% of the...
33 CFR 127.203 - Portable gas detectors.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 33 Navigation and Navigable Waters 2 2013-07-01 2013-07-01 false Portable gas detectors. 127.203... Waterfront Facilities Handling Liquefied Natural Gas Equipment § 127.203 Portable gas detectors. The marine transfer area for LNG must have at least two portable gas detectors capable of measuring 0-100% of the...
33 CFR 127.203 - Portable gas detectors.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Portable gas detectors. 127.203... Waterfront Facilities Handling Liquefied Natural Gas Equipment § 127.203 Portable gas detectors. The marine transfer area for LNG must have at least two portable gas detectors capable of measuring 0-100% of the...
48 CFR 1852.237-71 - Pension portability.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 48 Federal Acquisition Regulations System 6 2010-10-01 2010-10-01 true Pension portability. 1852... 1852.237-71 Pension portability. As prescribed at 1837.110-70(b), insert the following clause: Pension Portability (JAN 1997) (a) In order for pension costs attributable to employees assigned to this contract to...
46 CFR 183.430 - Portable lights
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 7 2010-10-01 2010-10-01 false Portable lights 183.430 Section 183.430 Shipping COAST...) ELECTRICAL INSTALLATION Lighting Systems § 183.430 Portable lights Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and...
46 CFR 183.430 - Portable lights
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 7 2011-10-01 2011-10-01 false Portable lights 183.430 Section 183.430 Shipping COAST...) ELECTRICAL INSTALLATION Lighting Systems § 183.430 Portable lights Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and...
46 CFR 183.430 - Portable lights
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 7 2013-10-01 2013-10-01 false Portable lights 183.430 Section 183.430 Shipping COAST...) ELECTRICAL INSTALLATION Lighting Systems § 183.430 Portable lights Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and...
46 CFR 183.430 - Portable lights
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 7 2014-10-01 2014-10-01 false Portable lights 183.430 Section 183.430 Shipping COAST...) ELECTRICAL INSTALLATION Lighting Systems § 183.430 Portable lights Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and...
46 CFR 183.430 - Portable lights
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 7 2012-10-01 2012-10-01 false Portable lights 183.430 Section 183.430 Shipping COAST...) ELECTRICAL INSTALLATION Lighting Systems § 183.430 Portable lights Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and...
DASTCOM5: A Portable and Current Database of Asteroid and Comet Orbit Solutions
NASA Astrophysics Data System (ADS)
Giorgini, Jon D.; Chamberlin, Alan B.
2014-11-01
A portable direct-access database containing all NASA/JPL asteroid and comet orbit solutions, with the software to access it, is available for download (ftp://ssd.jpl.nasa.gov/pub/xfr/dastcom5.zip; unzip -ao dastcom5.zip). DASTCOM5 contains the latest heliocentric IAU76/J2000 ecliptic osculating orbital elements for all known asteroids and comets as determined by a least-squares best-fit to ground-based optical, spacecraft, and radar astrometric measurements. Other physical, dynamical, and covariance parameters are included when known. A total of 142 parameters per object are supported within DASTCOM5. This information is suitable for initializing high-precision numerical integrations, assessing orbit geometry, computing trajectory uncertainties, visual magnitude, and summarizing physical characteristics of the body. The DASTCOM5 distribution is updated as often as hourly to include newly discovered objects or orbit solution updates. It includes an ASCII index of objects that supports look-ups based on name, current or past designation, SPK ID, MPC packed-designations, or record number. DASTCOM5 is the database used by the NASA/JPL Horizons ephemeris system. It is a subset exported from a larger MySQL-based relational Small-Body Database ("SBDB") maintained at JPL. The DASTCOM5 distribution is intended for programmers comfortable with UNIX/LINUX/MacOSX command-line usage who need to develop stand-alone applications. The goal of the implementation is to provide small, fast, portable, and flexibly programmatic access to JPL comet and asteroid orbit solutions. The supplied software library, examples, and application programs have been verified under gfortran, Lahey, Intel, and Sun 32/64-bit Linux/UNIX FORTRAN compilers. A command-line tool ("dxlook") is provided to enable database access from shell or script environments.
Blasim: A computational tool to assess ice impact damage on engine blades
NASA Astrophysics Data System (ADS)
Reddy, E. S.; Abumeri, G. H.; Chamis, C. C.
1993-04-01
A portable computer called BLASIM was developed at NASA LeRC to assess ice impact damage on aircraft engine blades. In addition to ice impact analyses, the code also contains static, dynamic, resonance margin, and supersonic flutter analysis capabilities. Solid, hollow, superhybrid, and composite blades are supported. An optional preprocessor (input generator) was also developed to interactively generate input for BLASIM. The blade geometry can be defined using a series of airfoils at discrete input stations or by a finite element grid. The code employs a coarse, fixed finite element mesh containing triangular plate finite elements to minimize program execution time. Ice piece is modeled using an equivalent spherical objective that has a high velocity opposite that of the aircraft and parallel to the engine axis. For local impact damage assessment, the impact load is considered as a distributed force acting over a region around the impact point. The average radial strain of the finite elements along the leading edge is used as a measure of the local damage. To estimate damage at the blade root, the impact is treated as an impulse and a combined stress failure criteria is employed. Parametric studies of local and root ice impact damage, and post-impact dynamics are discussed for solid and composite blades.
5 CFR 870.1205 - Electing portability for Option B.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 5 Administrative Personnel 2 2010-01-01 2010-01-01 false Electing portability for Option B. 870... portability for Option B. (a) The employing agency must notify the employee/assignee(s) of the loss of coverage and the right to elect portability for Option B either before or immediately after the event...
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 4 2014-10-01 2014-10-01 false Servicing of hand portable fire extinguishers, semi-portable fire extinguishers and fixed fire extinguishing systems. 107.235 Section 107.235 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS INSPECTION AND...
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Servicing of hand portable fire extinguishers, semi-portable fire extinguishers and fixed fire-extinguishing systems. 107.235 Section 107.235 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS INSPECTION AND...
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Servicing of hand portable fire extinguishers, semi-portable fire extinguishers and fixed fire-extinguishing systems. 107.235 Section 107.235 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS INSPECTION AND...
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Servicing of hand portable fire extinguishers, semi-portable fire extinguishers and fixed fire extinguishing systems. 107.235 Section 107.235 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS INSPECTION AND...
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false Servicing of hand portable fire extinguishers, semi-portable fire extinguishers and fixed fire extinguishing systems. 107.235 Section 107.235 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS INSPECTION AND...
Engineering Resilience Into The Marine Expeditionary Units Resupply System Through Military Foraging
2017-09-01
19 Figure 7. Solar Portable Alternative Communications Energy System ( SPACES ) Source...sustained operations ashore SPACES solar portable alternative communications energy system STOM ship-to-objective maneuver STSM ship-to-shore movement... Communications Energy System Solar Portable Alternative Communications Energy System ( SPACES ) is a man-portable energy generation system for mounted
30 CFR 77.601 - Trailing cables or portable cables; temporary splices.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Trailing cables or portable cables; temporary... OF UNDERGROUND COAL MINES Trailing Cables § 77.601 Trailing cables or portable cables; temporary splices. Temporary splices in trailing cables or portable cables shall be made in a workmanlike manner and...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-12-14
... (VOC) from Consumer and Commercial Products, Section 3.0--Portable Fuel Containers. This amendment will... Organic Compounds from Consumer and Commercial Products, Section 3.0--Portable Fuel Containers). I... Products, Section 3.0--Portable Fuel Containers is concerned specifically with the use of portable fuel...
Code of Federal Regulations, 2013 CFR
2013-01-01
... 14 Aeronautics and Space 3 2013-01-01 2013-01-01 false Rules for use of portable oxygen... portable oxygen concentrator systems on board aircraft Section 1. Applicability—This rule prescribes special operating rules for the use of portable oxygen concentrator units on board civil aircraft. This...
Code of Federal Regulations, 2014 CFR
2014-01-01
... 14 Aeronautics and Space 3 2014-01-01 2014-01-01 false Rules for use of portable oxygen... portable oxygen concentrator systems on board aircraft Section 1. Applicability—This rule prescribes special operating rules for the use of portable oxygen concentrator units on board civil aircraft. This...
Portable Tablets in Science Museum Learning: Options and Obstacles
ERIC Educational Resources Information Center
Gronemann, Sigurd Trolle
2017-01-01
Despite the increasing use of portable tablets in learning, their impact has received little attention in research. In five different projects, this media-ethnographic and design-based analysis of the use of portable tablets as a learning resource in science museums investigates how young people's learning with portable tablets matches the…
46 CFR 120.430 - Portable lights.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Portable lights. 120.430 Section 120.430 Shipping COAST... Systems § 120.430 Portable lights. Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access...
46 CFR 120.430 - Portable lights.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false Portable lights. 120.430 Section 120.430 Shipping COAST... Systems § 120.430 Portable lights. Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access...
46 CFR 120.430 - Portable lights.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Portable lights. 120.430 Section 120.430 Shipping COAST... Systems § 120.430 Portable lights. Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access...
46 CFR 120.430 - Portable lights.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 4 2014-10-01 2014-10-01 false Portable lights. 120.430 Section 120.430 Shipping COAST... Systems § 120.430 Portable lights. Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access...
46 CFR 120.430 - Portable lights.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Portable lights. 120.430 Section 120.430 Shipping COAST... Systems § 120.430 Portable lights. Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access...
NASA Astrophysics Data System (ADS)
Kaiser, J.; Novotný, K.; Hrdlička, A.; Malina, R.; Novotný, J.; Prochazka, D.; Petrilak, M.; Krajcarová, L.; Vítková, G.; Kučerová, P.
2010-12-01
Here we report on the recent developments and upgrades of our Laser-Induced Breakdown Spectroscopy setups and their different modification for high-resolution mapping. Mapping capabilities of Laser-Induced Breakdown Spectroscopy (LIBS) and Laser Ablation Inductively Coupled Plasma Mass Spectrometry are compared. The applied improvements as an autofocus algorithm, together with the realization of double-pulse LIBS or combination of LIBS by Laser-Induced Fluorescence Spectroscopy (LIFS) with technique are detailed. The signal enhancement obtained by double-pulse approach is demonstrated. The state of the art on development of portable remote LIBS apparatus is also presented.
NASA Astrophysics Data System (ADS)
Grahmann, Jan; Merten, André; Ostendorf, Ralf; Fontenot, Michael; Bleh, Daniela; Schenk, Harald; Wagner, Hans-Joachim
2014-03-01
In situ process information in the chemical, pharmaceutical or food industry as well as emission monitoring, sensitive trace detection and biological sensing applications would increasingly rely on MIR-spectroscopic analysis in the 3 μm - 12 μm wavelength range. However, cost effective, portable, low power consuming and fast spectrometers with a wide tuning range are not available so far. To provide these MIR-spectrometer properties, the combination of quantum cascade lasers with a MOEMS scanning grating as wavelength selective element in the external cavity is addressed to provide a very compact and fast tunable laser source for spectroscopic analysis.
NASA Technical Reports Server (NTRS)
1982-01-01
A compact, lightweight electrolytic water sterilizer available through Ambassador Marketing, generates silver ions in concentrations of 50 to 100 parts per billion in water flow system. The silver ions serve as an effective bactericide/deodorizer. Tap water passes through filtering element of silver that has been chemically plated onto activated carbon. The silver inhibits bacterial growth and the activated carbon removes objectionable tastes and odors caused by addition of chlorine and other chemicals in municipal water supply. The three models available are a kitchen unit, a "Tourister" unit for portable use while traveling and a refrigerator unit that attaches to the ice cube water line. A filter will treat 5,000 to 10,000 gallons of water.
Lunar mission safety and rescue: Escape/rescue analysis and plan
NASA Technical Reports Server (NTRS)
1971-01-01
The results are presented of the technical analysis of escape/rescue/survival situations, crew survival techniques, alternate escape/rescue approaches and vehicles, and the advantages and disadvantages of each for advanced lunar exploration. Candidate escape/rescue guidelines are proposed and elements of a rescue plan developed. The areas of discussions include the following: lunar arrival/departure operations, lunar orbiter operations, lunar surface operations, lunar surface base escape/rescue analysis, lander tug location operations, portable airlock, emergency pressure suit, and the effects of no orbiting lunar station, no lunar surface base, and no foreign lunar orbit/surface operations on the escape/rescue plan.
NASA Technical Reports Server (NTRS)
Bayes, Stephen A.; Trevino, Luis A.; Dinsmore, Craig E.
1988-01-01
This paper outlines the selection, design, and testing of a prototype nonventing regenerable astronaut cooling system for extravehicular activity space suit applications, for mission durations of four hours or greater. The selected system consists of the following key elements: a radiator assembly which serves as the exterior shell of the portable life support subsystem backpack; a layer of phase change thermal storage material, n-hexadecane paraffin, which acts as a regenerable thermal capacitor; a thermoelectric heat pump; and an automatic temperature control system. The capability for regeneration of thermal storage capacity with and without the aid of electric power is provided.
2012-04-05
C la ss ifi ca tio n TY PE D ep th (M ) A zi m ut h (D eg re es ) D ip (D eg re es ) 1 2 3...Naval Research Laboratory Washington, DC 20375-5320 NRL/MR/ 6110 --12-9401 TEMTADS Adjunct Sensor Systems Hand-held EMI Sensor for Cued UXO...NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 5d. PROJECT NUMBER 5e. TASK NUMBER 5f. WORK UNIT NUMBER 2 . REPORT TYPE1. REPORT DATE (DD-MM-YYYY) 4
2012-06-27
notes and team orienteering functions. Data collection with the MP system at the former Camp Beale, CA is shown in Figure 5- 2 (right). 5.3.3...Naval Research Laboratory Washington, DC 20375-5320 NRL/MR/ 6110 --12-9424 TEMTADS Adjunct Sensor Systems Hand-held EMI Sensor for Cued UXO...CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 5d. PROJECT NUMBER 5e. TASK NUMBER 5f. WORK UNIT NUMBER 2 . REPORT TYPE1. REPORT DATE (DD
Mobile Sensor Technologies Being Developed
NASA Technical Reports Server (NTRS)
Greer, Lawrence C.; Oberle, Lawrence G.
2003-01-01
The NASA Glenn Research Center is developing small mobile platforms for sensor placement, as well as methods for communicating between roving platforms and a central command location. The first part of this project is to use commercially available equipment to miniaturize an existing sensor platform. We developed a five-circuit-board suite, with an average board size of 1.5 by 3 cm. Shown in the preceding photograph, this suite provides all motor control, direction finding, and communications capabilities for a 27- by 21- by 40-mm prototype mobile platform. The second part of the project is to provide communications between mobile platforms, and also between multiple platforms and a central command location. This is accomplished with a low-power network labeled "SPAN," Sensor Platform Area Network, a local area network made up of proximity elements. In practice, these proximity elements are composed of fixed- and mobile-sensor-laden science packages that communicate to each other via radiofrequency links. Data in the network will be shared by a central command location that will pass information into and out of the network through its access to a backbone element. The result will be a protocol portable to general purpose microcontrollers satisfying a host of sensor networking tasks. This network will enter the gap somewhere between television remotes and Bluetooth but, unlike 802.15.4, will not specify a physical layer, thus allowing for many data rates over optical, acoustical, radiofrequency, hardwire, or other media. Since the protocol will exist as portable C-code, developers may be able to embed it in a host of microcontrollers from commercial to space grade and, of course, to design it into ASICs. Unlike in 802.15.4, the nodes will relate to each other as peers. A demonstration of this protocol using the two test bed platforms was recently held. Two NASA modified, commercially available, mobile platforms communicated and shared data with each other and a central command location. Web-based control and interrogation of similar mobile sensor platforms have also been demonstrated. Expected applications of this technology include robotic planetary exploration, astronaut-to-equipment communication, and remote aerospace engine inspections.
The sonic window: second generation results
NASA Astrophysics Data System (ADS)
Walker, William F.; Fuller, Michael I.; Brush, Edward V.; Eames, Matthew D. C.; Owen, Kevin; Ranganathan, Karthik; Blalock, Travis N.; Hossack, John A.
2006-03-01
Medical Ultrasound Imaging is widely used clinically because of its relatively low cost, portability, lack of ionizing radiation, and real-time nature. However, even with these advantages ultrasound has failed to permeate the broad array of clinical applications where its use could be of value. A prime example of this untapped potential is the routine use of ultrasound to guide intravenous access. In this particular application existing systems lack the required portability, low cost, and ease-of-use required for widespread acceptance. Our team has been working for a number of years to develop an extremely low-cost, pocket-sized, and intuitive ultrasound imaging system that we refer to as the "Sonic Window." We have previously described the first generation Sonic Window prototype that was a bench-top device using a 1024 element, fully populated array operating at a center frequency of 3.3 MHz. Through a high degree of custom front-end integration combined with multiplexing down to a 2 channel PC based digitizer this system acquired a full set of RF data over a course of 512 transmit events. While initial results were encouraging, this system exhibited limitations resulting from low SNR, relatively coarse array sampling, and relatively slow data acquisition. We have recently begun assembling a second-generation Sonic Window system. This system uses a 3600 element fully sampled array operating at 5.0 MHz with a 300 micron element pitch. This system extends the integration of the first generation system to include front-end protection, pre-amplification, a programmable bandpass filter, four sample and holds, and four A/D converters for all 3600 channels in a set of custom integrated circuits with a combined area smaller than the 1.8 x 1.8 cm footprint of the transducer array. We present initial results from this front-end and present benchmark results from a software beamformer implemented on the Analog Devices BF-561 DSP. We discuss our immediate plans for further integration and testing. This second prototype represents a major reduction in size and forms the foundation of a fully functional, fully integrated, pocket sized prototype.
Portable Chemical Sterilizer (PCS) for Surgical Instruments
2004-12-01
PORTABLE CHEMICAL STERILIZER (PCS) FOR SURGICAL INSTRUMENTS CJ Doona*, FE Feeherry, MA Curtin‡, K Kustin‡, S Kandlikar‡ U.S. Army-Soldier...denotes Contractors) Biomedical Technologies ABSTRACT A novel device called the Portable Chemical Sterilizer (PCS) has been developed for the...rapid, safe, portable, power-free, and convenient sterilization of objects or surfaces contaminated with pathogenic microorganisms that cause
46 CFR 98.30-9 - Stowage of portable tanks.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false Stowage of portable tanks. 98.30-9 Section 98.30-9... CONSTRUCTION, ARRANGEMENT, AND OTHER PROVISIONS FOR CERTAIN DANGEROUS CARGOES IN BULK Portable Tanks § 98.30-9 Stowage of portable tanks. (a) No person may operate a vessel to which this subpart applies unless each...
46 CFR 98.30-9 - Stowage of portable tanks.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Stowage of portable tanks. 98.30-9 Section 98.30-9... CONSTRUCTION, ARRANGEMENT, AND OTHER PROVISIONS FOR CERTAIN DANGEROUS CARGOES IN BULK Portable Tanks § 98.30-9 Stowage of portable tanks. (a) No person may operate a vessel to which this subpart applies unless each...
NASA Astrophysics Data System (ADS)
Van Hoose, A. E.; Wolff, J.; Conrey, R.
2013-12-01
Advances in portable X-Ray fluorescence (pXRF) analytical technology have made it possible for high-quality, quantitative data to be collected in a fraction of the time required by standard, non-portable analytical techniques. Not only do these advances reduce analysis time, but data may also be collected in the field in conjunction with sampling. Rhyolitic pumice, being primarily glass, is an excellent material to be analyzed with this technology. High-quality, quantitative data for elements that are tracers of magmatic differentiation (e.g. Rb, Sr, Y, Nb) can be collected for whole, individual pumices and subsamples of larger pumices in 4 minutes. We have developed a calibration for powdered rhyolite pumice from the Otowi Member of the Bandelier Tuff analyzed with the Bruker Tracer IV pXRF using Bruker software and influence coefficients for pumice, which measures the following 19 oxides and elements: SiO2, TiO2, Al2O3, FeO*, MnO, CaO, K2O, P2O5, Zn, Ga, Rb, Sr, Y, Zr, Nb, Ba, Ce, Pb, and Th. With this calibration for the pXRF and thousands of individual powdered pumice samples, we have generated an unparalleled data set for any single eruptive unit with known trace element zonation. The Bandelier Tuff of the Valles-Toledo Caldera Complex, Jemez Mountains, New Mexico, is divided into three main eruptive events. For this study, we have chosen the 1.61 Ma, 450 km3 Otowi Member as it is primarily unwelded and pumice samples are easily accessible. The eruption began with a plinian phase from a single source located near center of the current caldera and deposited the Guaje Pumice Bed. The initial Unit A of the Guaje is geochemically monotonous, but Units B through E, co-deposited with ignimbrite show very strong chemical zonation in trace elements, progressing upwards through the deposits from highly differentiated compositions (Rb ~350 ppm, Nb ~200 ppm) to less differentiated (Rb ~100 ppm, Nb ~50 ppm). Co-erupted ignimbrites emplaced during column collapse show similar trace element zonation. The eruption culminated in caldera collapse after transitioning from a single central vent to ring fracture vents. Ignimbrites deposited at this time have lithic breccias and chaotic geochemical profiles. The geochemical discrepancy between early and late deposits warrants detailed, high-resolution sampling and analysis in order to fully understand the dynamics behind zonation processes. Samples were collected from locations that circumvent the caldera and prepared and analyzed in the field and the laboratory with the pXRF. Approximately 2,000 pumice samples will complete this unprecedented data set, allowing detailed reconstruction of trace element zonation around all sides of the Valles Caldera. These data are then used to constrain models of magma chamber processes that produce trace element zonation and how it is preserved in the deposits after a catastrophic, caldera-forming eruption.
Choi, Jong Hwan; Choi, Jae Hyuk; Lee, Yoo Jin; Lee, Hyung Ki; Choi, Wang Yong; Kim, Eun Soo; Park, Kyung Sik; Cho, Kwang Bum; Jang, Byoung Kuk; Chung, Woo Jin; Hwang, Jae Seok
2014-07-07
To compare outcomes using the novel portable endoscopy with that of nasogastric (NG) aspiration in patients with gastrointestinal bleeding. Patients who underwent NG aspiration for the evaluation of upper gastrointestinal (UGI) bleeding were eligible for the study. After NG aspiration, we performed the portable endoscopy to identify bleeding evidence in the UGI tract. Then, all patients underwent conventional esophagogastroduodenoscopy as the gold-standard test. The sensitivity, specificity, and accuracy of the portable endoscopy for confirming UGI bleeding were compared with those of NG aspiration. In total, 129 patients who had GI bleeding signs or symptoms were included in the study (age 64.46 ± 13.79, 91 males). The UGI tract (esophagus, stomach, and duodenum) was the most common site of bleeding (81, 62.8%) and the cause of bleeding was not identified in 12 patients (9.3%). Specificity for identifying UGI bleeding was higher with the portable endoscopy than NG aspiration (85.4% vs 68.8%, P = 0.008) while accuracy was comparable. The accuracy of the portable endoscopy was significantly higher than that of NG in the subgroup analysis of patients with esophageal bleeding (88.2% vs 75%, P = 0.004). Food material could be detected more readily by the portable endoscopy than NG tube aspiration (20.9% vs 9.3%, P = 0.014). No serious adverse effect was observed during the portable endoscopy. The portable endoscopy was not superior to NG aspiration for confirming UGI bleeding site. However, this novel portable endoscopy device might provide a benefit over NG aspiration in patients with esophageal bleeding.
Portable monitoring for the diagnosis of obstructive sleep apnea.
Collop, Nancy A
2008-11-01
The demand for expedient diagnosis of suspected obstructive sleep apnea (OSA) has increased due to improved awareness of sleep disorders. Polysomnography (PSG) is the current preferred diagnostic modality but is relatively inconvenient, expensive and inefficient. Portable monitoring has been developed and is widely used in countries outside the United States as an alternative approach. A portable monitor records fewer physiologic variables but is typically unattended and can be performed in the home. Numerous portable monitor studies have been performed over the past two to three decades. The US government and medical societies have extensively reviewed this literature several times in an attempt to determine if portable monitoring should be more broadly used for diagnosing OSA. In March 2008, the US Centers for Medicare and Medicaid Services released a statement allowing the use of portable monitoring to diagnose OSA and prescribe continuous positive airway pressure. This has potentially opened the door for more widespread use of these devices. This review will focus on the literature that has examined portable monitoring as a diagnostic tool for OSA. It is anticipated that portable monitoring as a diagnostic modality for OSA will be used more frequently in the United States following the Centers for Medicare and Medicaid Services ruling. Physicians and others considering the use of portable monitors should thoroughly understand the advantages and limitations of this technology.
30 CFR Appendix I to Subpart D of... - Appendix I to Subpart D of Part 18
Code of Federal Regulations, 2012 CFR
2012-07-01
... LIST OF TABLES Table No. Title 1 Portable power cable ampacities—600 volts. 2 Portable cord ampacities—600 volts. 3 Portable power cable ampacities—601 to 5,000 volts. 4 Normal diameter of round cables... diameter of three-conductor portable power cables with tolerances in inches—601 to 5,000 volts. 8 Fuse...
30 CFR Appendix I to Subpart D of... - Appendix I to Subpart D of Part 18
Code of Federal Regulations, 2014 CFR
2014-07-01
... LIST OF TABLES Table No. Title 1 Portable power cable ampacities—600 volts. 2 Portable cord ampacities—600 volts. 3 Portable power cable ampacities—601 to 5,000 volts. 4 Normal diameter of round cables... diameter of three-conductor portable power cables with tolerances in inches—601 to 5,000 volts. 8 Fuse...
Leary, Pauline E; Dobson, Gareth S; Reffner, John A
2016-05-01
Portable gas chromatography-mass spectrometry (GC-MS) systems are being deployed for field use, and are designed with this goal in mind. Performance characteristics of instruments that are successful in the field are different from those of equivalent technologies that are successful in a laboratory setting. These field-portable systems are extending the capabilities of the field user, providing investigative leads and confirmatory identifications in real time. Many different types of users benefit from the availability of this technology including emergency responders, the military, and law-enforcement organizations. This manuscript describes performance characteristics that are important for field-portable instruments, especially field-portable GC-MS systems, and demonstrates the value of this equipment to the disciplines of explosives investigations, fire investigations, and counterfeit-drug detection. This paper describes the current state of portable GC-MS technology, including a review of the development of portable GC-MS, as well as a demonstration of the value of this capability using different examples. © The Author(s) 2016.
Satellite sound broadcasting system, portable reception
NASA Technical Reports Server (NTRS)
Golshan, Nasser; Vaisnys, Arvydas
1990-01-01
Studies are underway at JPL in the emerging area of Satellite Sound Broadcast Service (SSBS) for direct reception by low cost portable, semi portable, mobile and fixed radio receivers. This paper addresses the portable reception of digital broadcasting of monophonic audio with source material band limited to 5 KHz (source audio comparable to commercial AM broadcasting). The proposed system provides transmission robustness, uniformity of performance over the coverage area and excellent frequency reuse. Propagation problems associated with indoor portable reception are considered in detail and innovative antenna concepts are suggested to mitigate these problems. It is shown that, with the marriage of proper technologies a single medium power satellite can provide substantial direct satellite audio broadcast capability to CONUS in UHF or L Bands, for high quality portable indoor reception by low cost radio receivers.
Diaz, Javier; Arrizabalaga, Saioa; Bustamante, Paul; Mesa, Iker; Añorga, Javier; Goya, Jon
2013-01-01
Portable systems and global communications open a broad spectrum for new health applications. In the framework of electrophysiological applications, several challenges are faced when developing portable systems embedded in Cloud computing services. In order to facilitate new developers in this area based on our experience, five areas of interest are presented in this paper where strategies can be applied for improving the performance of portable systems: transducer and conditioning, processing, wireless communications, battery and power management. Likewise, for Cloud services, scalability, portability, privacy and security guidelines have been highlighted.
Embedded Data Processor and Portable Computer Technology testbeds
NASA Technical Reports Server (NTRS)
Alena, Richard; Liu, Yuan-Kwei; Goforth, Andre; Fernquist, Alan R.
1993-01-01
Attention is given to current activities in the Embedded Data Processor and Portable Computer Technology testbed configurations that are part of the Advanced Data Systems Architectures Testbed at the Information Sciences Division at NASA Ames Research Center. The Embedded Data Processor Testbed evaluates advanced microprocessors for potential use in mission and payload applications within the Space Station Freedom Program. The Portable Computer Technology (PCT) Testbed integrates and demonstrates advanced portable computing devices and data system architectures. The PCT Testbed uses both commercial and custom-developed devices to demonstrate the feasibility of functional expansion and networking for portable computers in flight missions.
46 CFR 162.028-5 - Independent laboratories: Listing.
Code of Federal Regulations, 2014 CFR
2014-10-01
... MATERIALS: SPECIFICATIONS AND APPROVAL ENGINEERING EQUIPMENT Extinguishers, Fire, Portable, Marine Type... or tests of portable fire extinguishers: (a) For dry chemical, CO2, water and foam type portable fire...
46 CFR 162.028-5 - Independent laboratories: Listing.
Code of Federal Regulations, 2011 CFR
2011-10-01
... MATERIALS: SPECIFICATIONS AND APPROVAL ENGINEERING EQUIPMENT Extinguishers, Fire, Portable, Marine Type... or tests of portable fire extinguishers: (a) For dry chemical, CO2, water and foam type portable fire...
46 CFR 162.028-5 - Independent laboratories: Listing.
Code of Federal Regulations, 2013 CFR
2013-10-01
... MATERIALS: SPECIFICATIONS AND APPROVAL ENGINEERING EQUIPMENT Extinguishers, Fire, Portable, Marine Type... or tests of portable fire extinguishers: (a) For dry chemical, CO2, water and foam type portable fire...
46 CFR 162.028-5 - Independent laboratories: Listing.
Code of Federal Regulations, 2010 CFR
2010-10-01
... MATERIALS: SPECIFICATIONS AND APPROVAL ENGINEERING EQUIPMENT Extinguishers, Fire, Portable, Marine Type... or tests of portable fire extinguishers: (a) For dry chemical, CO2, water and foam type portable fire...
46 CFR 162.028-5 - Independent laboratories: Listing.
Code of Federal Regulations, 2012 CFR
2012-10-01
... MATERIALS: SPECIFICATIONS AND APPROVAL ENGINEERING EQUIPMENT Extinguishers, Fire, Portable, Marine Type... or tests of portable fire extinguishers: (a) For dry chemical, CO2, water and foam type portable fire...
Surface Plasmon Resonance Biosensor Based on Smart Phone Platforms
NASA Astrophysics Data System (ADS)
Liu, Yun; Liu, Qiang; Chen, Shimeng; Cheng, Fang; Wang, Hanqi; Peng, Wei
2015-08-01
We demonstrate a fiber optic surface plasmon resonance (SPR) biosensor based on smart phone platforms. The light-weight optical components and sensing element are connected by optical fibers on a phone case. This SPR adaptor can be conveniently installed or removed from smart phones. The measurement, control and reference channels are illuminated by the light entering the lead-in fibers from the phone’s LED flash, while the light from the end faces of the lead-out fibers is detected by the phone’s camera. The SPR-sensing element is fabricated by a light-guiding silica capillary that is stripped off its cladding and coated with 50-nm gold film. Utilizing a smart application to extract the light intensity information from the camera images, the light intensities of each channel are recorded every 0.5 s with refractive index (RI) changes. The performance of the smart phone-based SPR platform for accurate and repeatable measurements was evaluated by detecting different concentrations of antibody binding to a functionalized sensing element, and the experiment results were validated through contrast experiments with a commercial SPR instrument. This cost-effective and portable SPR biosensor based on smart phones has many applications, such as medicine, health and environmental monitoring.
Surface Plasmon Resonance Biosensor Based on Smart Phone Platforms.
Liu, Yun; Liu, Qiang; Chen, Shimeng; Cheng, Fang; Wang, Hanqi; Peng, Wei
2015-08-10
We demonstrate a fiber optic surface plasmon resonance (SPR) biosensor based on smart phone platforms. The light-weight optical components and sensing element are connected by optical fibers on a phone case. This SPR adaptor can be conveniently installed or removed from smart phones. The measurement, control and reference channels are illuminated by the light entering the lead-in fibers from the phone's LED flash, while the light from the end faces of the lead-out fibers is detected by the phone's camera. The SPR-sensing element is fabricated by a light-guiding silica capillary that is stripped off its cladding and coated with 50-nm gold film. Utilizing a smart application to extract the light intensity information from the camera images, the light intensities of each channel are recorded every 0.5 s with refractive index (RI) changes. The performance of the smart phone-based SPR platform for accurate and repeatable measurements was evaluated by detecting different concentrations of antibody binding to a functionalized sensing element, and the experiment results were validated through contrast experiments with a commercial SPR instrument. This cost-effective and portable SPR biosensor based on smart phones has many applications, such as medicine, health and environmental monitoring.
29 CFR 1917.119 - Portable ladders.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Requirements for Portable Reinforced Plastic Ladders (d) Standards for job-made portable ladders. Job-made... usage. (1) Ladders made by fastening rungs or devices across a single rail are prohibited. (2) Ladders...
Wygant, Ira O; Jamal, Nafis S; Lee, Hyunjoo J; Nikoozadeh, Amin; Oralkan, Omer; Karaman, Mustafa; Khuri-Yakub, Butrus T
2009-10-01
State-of-the-art 3-D medical ultrasound imaging requires transmitting and receiving ultrasound using a 2-D array of ultrasound transducers with hundreds or thousands of elements. A tight combination of the transducer array with integrated circuitry eliminates bulky cables connecting the elements of the transducer array to a separate system of electronics. Furthermore, preamplifiers located close to the array can lead to improved receive sensitivity. A combined IC and transducer array can lead to a portable, high-performance, and inexpensive 3-D ultrasound imaging system. This paper presents an IC flip-chip bonded to a 16 x 16-element capacitive micromachined ultrasonic transducer (CMUT) array for 3-D ultrasound imaging. The IC includes a transmit beamformer that generates 25-V unipolar pulses with programmable focusing delays to 224 of the 256 transducer elements. One-shot circuits allow adjustment of the pulse widths for different ultrasound transducer center frequencies. For receiving reflected ultrasound signals, the IC uses the 32-elements along the array diagonals. The IC provides each receiving element with a low-noise 25-MHz-bandwidth transimpedance amplifier. Using a field-programmable gate array (FPGA) clocked at 100 MHz to operate the IC, the IC generated properly timed transmit pulses with 5-ns accuracy. With the IC flip-chip bonded to a CMUT array, we show that the IC can produce steered and focused ultrasound beams. We present 2-D and 3-D images of a wire phantom and 2-D orthogonal cross-sectional images (Bscans) of a latex heart phantom.
Choi, Jong Hwan; Choi, Jae Hyuk; Lee, Yoo Jin; Lee, Hyung Ki; Choi, Wang Yong; Kim, Eun Soo; Park, Kyung Sik; Cho, Kwang Bum; Jang, Byoung Kuk; Chung, Woo Jin; Hwang, Jae Seok
2014-01-01
AIM: To compare outcomes using the novel portable endoscopy with that of nasogastric (NG) aspiration in patients with gastrointestinal bleeding. METHODS: Patients who underwent NG aspiration for the evaluation of upper gastrointestinal (UGI) bleeding were eligible for the study. After NG aspiration, we performed the portable endoscopy to identify bleeding evidence in the UGI tract. Then, all patients underwent conventional esophagogastroduodenoscopy as the gold-standard test. The sensitivity, specificity, and accuracy of the portable endoscopy for confirming UGI bleeding were compared with those of NG aspiration. RESULTS: In total, 129 patients who had GI bleeding signs or symptoms were included in the study (age 64.46 ± 13.79, 91 males). The UGI tract (esophagus, stomach, and duodenum) was the most common site of bleeding (81, 62.8%) and the cause of bleeding was not identified in 12 patients (9.3%). Specificity for identifying UGI bleeding was higher with the portable endoscopy than NG aspiration (85.4% vs 68.8%, P = 0.008) while accuracy was comparable. The accuracy of the portable endoscopy was significantly higher than that of NG in the subgroup analysis of patients with esophageal bleeding (88.2% vs 75%, P = 0.004). Food material could be detected more readily by the portable endoscopy than NG tube aspiration (20.9% vs 9.3%, P = 0.014). No serious adverse effect was observed during the portable endoscopy. CONCLUSION: The portable endoscopy was not superior to NG aspiration for confirming UGI bleeding site. However, this novel portable endoscopy device might provide a benefit over NG aspiration in patients with esophageal bleeding. PMID:25009396
Capillary Optics Based X-Ray Micro-Imaging Elemental Analysis
NASA Astrophysics Data System (ADS)
Hampai, D.; Dabagov, S. B.; Cappuccio, G.; Longoni, A.; Frizzi, T.; Cibin, G.
2010-04-01
A rapidly developed during the last few years micro-X-ray fluorescence spectrometry (μXRF) is a promising multi-elemental technique for non-destructive analysis. Typically it is rather hard to perform laboratory μXRF analysis because of the difficulty of producing an original small-size X-ray beam as well as its focusing. Recently developed for X-ray beam focusing polycapillary optics offers laboratory X-ray micro probes. The combination of polycapillary lens and fine-focused micro X-ray tube can provide high intensity radiation flux on a sample that is necessary in order to perform the elemental analysis. In comparison to a pinhole, an optimized "X-ray source-op tics" system can result in radiation density gain of more than 3 orders by the value. The most advanced way to get that result is to use the confocal configuration based on two X-ray lenses, one for the fluorescence excitation and the other for the detection of secondary emission from a sample studied. In case of X-ray capillary microfocusing a μXRF instrument designed in the confocal scheme allows us to obtain a 3D elemental mapping. In this work we will show preliminary results obtained with our prototype, a portable X-ray microscope for X-ray both imaging and fluorescence analysis; it enables μXRF elemental mapping simultaneously with X-ray imaging. A prototype of compact XRF spectrometer with a spatial resolution less than 100 μm has been designed.
Ivory, James D; Magee, Robert G
2009-06-01
Portable media consoles are becoming extremely popular devices for viewing a number of different types of media content, both for entertainment and for educational purposes. Given the increasingly heavy use of portable consoles as an alternative to traditional television-style monitors, it is important to investigate how physiological and psychological effects of portable consoles may differ from those of television-based consoles, because such differences in physiological and psychological responses may precipitate differences in the delivered content's effectiveness. Because portable consoles are popular as a delivery system for multiple types of media content, such as movies and video games, it is also important to investigate whether differences between the effects of portable and television-based consoles are consistent across multiple types of media. This article reports a 2 x 2 (console: portable or television-based x medium: video game or movie) mixed factorial design experiment with physiological arousal and self-reported flow experience as dependent variables, designed to explore whether console type affects media experiences and whether these effects are consistent across different media. Results indicate that portable media consoles evoke lower levels of physiological arousal and flow experience and that this effect is consistent for both video games and movies. These findings suggest that even though portable media consoles are often convenient compared to television-based consoles, the convenience may come at a cost in terms of the user experience.
A wireless sequentially actuated microvalve system
NASA Astrophysics Data System (ADS)
Baek, Seung-Ki; Yoon, Yong-Kyu; Jeon, Hye-Seon; Seo, Soonmin; Park, Jung-Hwan
2013-04-01
A wireless microvalve system was fabricated based on induction heating for flow control in microfluidics by sequential valve opening. In this approach, we used paraffin wax as a flow plug, which can be changed from solid to liquid with adjacent heating elements operated by induction heating. Programmable opening of valves was devised by using different thermal responses of metal discs to a magnetic field. Copper and nickel discs with a diameter of 2.5 mm and various thicknesses (50, 100 and 200 µm) were prepared as heating elements by a laser cutting method, and they were integrated in the microfluidic channel as part of the microvalve. A calorimetric test was used to measure the thermal properties of the discs in terms of kinds of metal and disc thickness. Sequential openings of the microvalves were performed using the difference in the thermal response of 100 µm thick copper disc and 50 µm thick nickel disc for short-interval openings and 200 µm thick copper disc and 100-µm-thick nickel disc for long-interval openings. The thermal effect on fluid samples as a result of induction heating of the discs was studied by investigating lysozyme denaturation. More heat was generated in heating elements made of copper than in those made of nickel, implying differences in the thermal response of heating elements made of copper and nickel. Also, the thickness of the heating elements affected the thermal response in the elements. Valve openings for short intervals of 1-5 s and long intervals of 15-23 s were achieved by using two sets of heating elements. There was no significant change in lysozyme activity by increasing the temperature of the heating discs. This study demonstrates that a wireless sequentially actuated microvalve system can provide programmed valve opening, portability, ease of fabrication and operation, disposability, and low cost.
NASA Astrophysics Data System (ADS)
Baranova, A. A.; Khokhlov, K. O.
2014-11-01
The aim of this study was to design a device for explosives detection. The study design is based on excited steady-state luminescence quenching registration. Sensor's material luminescence intensity reduction occurs due to an interaction of explosives vapours contained in the air. The decrease rate of the luminescence intensity indicates the concentration of vapours. To study the luminescent properties of the sensor element, its luminescence spectra excited by photons with energies in the range 280 - 425 nm were measured. The excitation photoluminescence spectra for luminescence bands of the sensor element were also measured. Excitation source was light emitting diode (375 nm) and luminescent signal receiver was a photodiode (430 - 650 nm) in device designed. The device is operated under control of a program. The algorithm provides multiple operating modes (configuration, calibration, measurement etc.). Thus this device is referred to the class of devices with increased sensitivity to the explosives vapors. The advantages of device are autonomic power, small weight and sizes, simplicity of device operation for measurements.
NASA Technical Reports Server (NTRS)
Kempel, Leo C.
1994-01-01
The Finite Element-Boundary Integral (FE-BI) technique was used to analyze the scattering and radiation properties of cavity-backed patch antennas recessed in a metallic groundplane. A program, CAVITY3D, was written and found to yield accurate results for large arrays without the usual high memory and computational demand associated with competing formulations. Recently, the FE-BI approach was extended to cavity-backed antennas recessed in an infinite, metallic circular cylinder. EXCALIBUR is a computer program written in the Radiation Laboratory of the University of Michigan which implements this formulation. This user manual gives a brief introduction to EXCALIBUR and some hints as to its proper use. As with all computational electromagnetics programs (especially finite element programs), skilled use and best performance are only obtained through experience. However, several important aspects of the program such as portability, geometry generation, interpretation of results, and custom modification are addressed.
Nguyen, Thi Anh Huong; Nguyen, Van Ri; Le, Duc Dung; Nguyen, Thi Thanh Binh; Cao, Van Hoang; Nguyen, Thi Kim Dung; Sáiz, Jorge; Hauser, Peter C; Mai, Thanh Duc
2016-07-29
The employment of an in-house-made capillary electrophoresis (CE) instrument with capacitively coupled contactless conductivity detection (C(4)D) as a simple and inexpensive solution for simultaneous determination of many rare earth elements (REEs) in ore samples from Vietnam, as well as in anti-corrosion coating samples is reported. 14 REEs (La, Ce, Pr, Nd, Sm, Eu, Gd, Tb, Dy, Ho, Er, Tm, Yb and Lu) were determined using an electrolyte composed of 20mM arginine and 10mM α-hydroxyisobutyric acid adjusted to pH 4.2 with acetic acid. The best detection limit achieved was 0.24mg/L using the developed CE-C(4)D method. Good agreement between results from CE-C(4)D and the confirmation method (ICP-MS) was achieved, with a coefficient of determination (r(2)) for the two pairs of data of 0.998. Copyright © 2016 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Ferrero, J. L.; Roldán, C.; Ardid, M.; Navarro, E.
1999-02-01
XRF analysis has allowed a quick and precise detection and identification of the inorganic elements that compose the yellow pigments in altarpieces of the XV and XVI centuries painted by the Valencian artists Miguel Alcañiz, Vicente Macip, Juan de Juanes, Hernando Yáñez de la Almedina and Hernando Llanos. The analyses have been carried out with an XRF portable system that consists of a tube of X-rays and detectors of Si(Li) and cadmium zinc telluride. This system has enabled a non-aggressive and non-destructive analysis of many pieces at the Museo de Bellas Artes of Valencia (Spain). Among the yellow pigments we have identified a pigment composed by lead and tin oxides named lead-tin yellow (Pb 2SnO 4), frequently used in European paintings from the XIV century until the first half of the XVIII century. This fact demonstrates the influence of elements and pictorial techniques from Europe to the region of Valencia.
2004-06-10
Microextraction and Analysis using Field-Portable Gas Chromatography-Mass Spectrometry Name of Candidate: CPT Michael J. Nack...and Analysis using Field-Portable Gas Chromatography-Mass Spectrometry Beyond brief excerpts is with the permission of the copyright owner, and...Pesticides in Environmental Waters with Solid Phase Microextraction and Analysis using Field-Portable Gas Chromatography-Mass Spectrometry
Portable classroom leads to partnership.
Le Ber, Jeanne Marie; Lombardo, Nancy T; Weber, Alice; Bramble, John
2004-01-01
Library faculty participation on the School of Medicine Curriculum Steering Committee led to a unique opportunity to partner technology and teaching utilizing the library's portable wireless classroom. The pathology lab course master expressed a desire to revise the curriculum using patient cases and direct access to the Web and library resources. Since the pathology lab lacked computers, the library's portable wireless classroom provided a solution. Originally developed to provide maximum portability and flexibility, the wireless classroom consists of ten laptop computers configured with wireless cards and an access point. While the portable wireless classroom led to a partnership with the School of Medicine, there were additional benefits and positive consequences for the library.
Portable Instrumentation for Real-Time Measurement of Scour at Bridges
DOT National Transportation Integrated Search
2000-12-01
Portable scour-measuring systems were developed to meet the requirements of three different applications: bridge inspections, limited-detail data collection, and detailed data collection. A portable scour-measuring system consists of four components:...
49 CFR 172.326 - Portable tanks.
Code of Federal Regulations, 2010 CFR
2010-10-01
... petroleum gas (LPG) that is unodorized as authorized in § 173.315(b)(1) unless it is legibly marked NON... the portable tank are not visible. (d) NON-ODORIZED marking on portable tanks containing LPG. After...
Bagworm bags as portable armour against invertebrate predators.
Sugiura, Shinji
2016-01-01
Some animals have evolved the use of environmental materials as "portable armour" against natural enemies. Portable bags that bagworm larvae (Lepidoptera: Psychidae) construct using their own silk and plant parts are generally believed to play an important role as a physical barrier against natural enemies. However, no experimental studies have tested the importance of bags as portable armour against predators. To clarify the defensive function, I studied the bagworm Eumeta minuscula and a potential predator Calosoma maximoviczi (Coleoptera: Carabidae). Under laboratory conditions, all bagworm larvae were attacked by carabid adults, but successfully defended themselves against the predators' mandibles using their own bags. The portable bags, which are composed mainly of host plant twigs, may function as a physical barrier against predator mandibles. To test this hypothesis, I removed the twig bags and replaced some with herb leaf bags; all bag-removed larvae were easily caught and predated by carabids, while all bag-replaced larvae could successfully defend themselves against carabid attacks. Therefore, various types of portable bags can protect bagworm larvae from carabid attacks. This is the first study to test the defensive function of bagworm portable bags against invertebrate predators.
Vogel, Michael W; Giorni, Andrea; Vegh, Viktor; Pellicer-Guridi, Ruben; Reutens, David C
2016-01-01
We studied the feasibility of generating the variable magnetic fields required for ultra-low field nuclear magnetic resonance relaxometry with dynamically adjustable permanent magnets. Our motivation was to substitute traditional electromagnets by distributed permanent magnets, increasing system portability. The finite element method (COMSOL®) was employed for the numerical study of a small permanent magnet array to calculate achievable magnetic field strength, homogeneity, switching time and magnetic forces. A manually operated prototype was simulated and constructed to validate the numerical approach and to verify the generated magnetic field. A concentric small permanent magnet array can be used to generate strong sample pre-polarisation and variable measurement fields for ultra-low field relaxometry via simple prescribed magnet rotations. Using the array, it is possible to achieve a pre-polarisation field strength above 100 mT and variable measurement fields ranging from 20-50 μT with 200 ppm absolute field homogeneity within a field-of-view of 5 x 5 x 5 cubic centimetres. A dynamic small permanent magnet array can generate multiple highly homogeneous magnetic fields required in ultra-low field nuclear magnetic resonance (NMR) and magnetic resonance imaging (MRI) instruments. This design can significantly reduce the volume and energy requirements of traditional systems based on electromagnets, improving portability considerably.
A Practical Cryogen-Free CO2 Purification and Freezing Technique for Stable Isotope Analysis.
Sakai, Saburo; Matsuda, Shinichi
2017-04-18
Since isotopic analysis by mass spectrometry began in the early 1900s, sample gas for light-element isotopic measurements has been purified by the use of cryogens and vacuum-line systems. However, this conventional purification technique can achieve only certain temperatures that depend on the cryogens and can be sustained only as long as there is a continuous cryogen supply. Here, we demonstrate a practical cryogen-free CO 2 purification technique using an electrical operated cryocooler for stable isotope analysis. This approach is based on portable free-piston Stirling cooling technology and controls the temperature to an accuracy of 0.1 °C in a range from room temperature to -196 °C (liquid-nitrogen temperature). The lowest temperature can be achieved in as little as 10 min. We successfully purified CO 2 gas generated by carbonates and phosphoric acid reaction and found its sublimation point to be -155.6 °C at 0.1 Torr in the vacuum line. This means that the temperature required for CO 2 trapping is much higher than the liquid-nitrogen temperature. Our portable cooling system offers the ability to be free from the inconvenience of cryogen use for stable isotope analysis. It also offers a new cooling method applicable to a number of fields that use gas measurements.
Computational Analysis of a Thermoelectric Generator for Waste-Heat Harvesting in Wearable Systems
NASA Astrophysics Data System (ADS)
Kossyvakis, D. N.; Vassiliadis, S. G.; Vossou, C. G.; Mangiorou, E. E.; Potirakis, S. M.; Hristoforou, E. V.
2016-06-01
Over recent decades, a constantly growing interest in the field of portable electronic devices has been observed. Recent developments in the scientific areas of integrated circuits and sensing technologies have enabled realization and design of lightweight low-power wearable sensing systems that can be of great use, especially for continuous health monitoring and performance recording applications. However, to facilitate wide penetration of such systems into the market, the issue of ensuring their seamless and reliable power supply still remains a major concern. In this work, the performance of a thermoelectric generator, able to exploit the temperature difference established between the human body and the environment, has been examined computationally using ANSYS 14.0 finite-element modeling (FEM) software, as a means for providing the necessary power to various portable electronic systems. The performance variation imposed due to different thermoelement geometries has been estimated to identify the most appropriate solution for the considered application. Furthermore, different ambient temperature and heat exchange conditions between the cold side of the generator and the environment have been investigated. The computational analysis indicated that power output in the order of 1.8 mW can be obtained by a 100-cm2 system, if specific design criteria can be fulfilled.
Honrado, Carlos; Dong, Tao
2014-01-01
Incidence of urinary tract infections (UTIs) is the second highest among all infections; thus, there is a high demand for bacteriuria detection. Escherichia coli are the main cause of UTIs, with microscopy methods and urine culture being the detection standard of these bacteria. However, the urine sampling and analysis required for these methods can be both time-consuming and complex. This work proposes a capacitive touch screen sensor (CTSS) concept as feasible alternative for a portable UTI detection device. Finite element method (FEM) simulations were conducted with a CTSS model. An exponential response of the model to increasing amounts of E. coli and liquid samples was observed. A measurable capacitance change due to E. coli presence and a tangible difference in the response given to urine and water samples were also detected. Preliminary experimental studies were also conducted on a commercial CTSS using liquid solutions with increasing amounts of dissolved ions. The CTSS was capable of distinguishing different volumes of liquids, also giving an exponential response. Furthermore, the CTSS gave higher responses to solutions with a superior amount of ions. Urine samples gave the top response among tested liquids. Thus, the CTSS showed the capability to differentiate solutions by their ionic content. PMID:25196109
NASA Astrophysics Data System (ADS)
Stremtan, Ciprian; Ashkanani, Hasan; Tykot, Robert H.
2013-04-01
The study of bi-phase (i.e. matrix and clasts) geochemical composition of ceramic artifacts is a very powerful tool in fingerprinting the raw materials used by ancient manufacturers (clay sources, tempering materials, coloring agents, etc.), as well as in understanding the physical parameters of the manufacturing techniques. Reliable datasets often require the deployment of destructive techniques that will irremediably damage the artifact. Recent advances in portable X-ray fluorescence instrumentation (pXRF) allow for quick measurements of a range of chemical elements that not too long ago were available only through complicated and often destructive means of analytical chemistry (instrumental neutron activation analysis - INAA, inductively coupled plasma mass spectrometry - ICP-MS, direct coupled plasma-optical emission spectroscopy - DCP-OES etc.). In this contribution we present a comparison of datasets acquired by means of pXRF, DCP-OES, and ICP-MS on Bronze Age ceramics from Failaka Island (Kuwait) and Bahrain. The samples chosen for this study are fine grained, with very well sorted mineral components, and lack any visible organic material fragments. The sample preparation for ICP-MS and DCP-OES analyses was carried out on powdered samples, by using LiBO2 flux fusion and Ge (for the DCP-OES) and In (for ICP-MS) were used as internal standards. The measurements were calibrated against certified reference materials ranging from shales to rhyolites (SGR-1, SDo-1, JA-2, and JR-1) and performed at Univerity of South Florida's Center for Geochemical Analyses. The analytical errors for major elements was smaller than 5 %, while for selected trace elements the error was usually smaller than 3 %. The same set of elements was measured on the same samples at University of South Florida's Anthropology Department using a pXRF device equipped with obsidian filter. Each sample was measured three times and the values were averaged. Two certified reference materials (NIST-612 glass and MACS-3 pressed powder) were also measured to check for accuracy and precision. Our preliminary data shows that most of the major and trace elemental data acquired by both methods are consistent. Some transition metals (e.g. Y, Fe, and Mn) yielded overall lower values when measured with pXRF device (ranging from 27 to 60 % difference), while Ni and Ba showed systematically higher values (20 to 53 %). If samples are chosen properly for pXRF measurements (i.e. thoroughly cleaned, fine grained, well sorted) and the device is properly calibrated, the results are comparable with DCP-OES and ICP-MS data, thus being suitable to use for geochemical fingerprinting
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-11
... Hydrostatic Testing Provision of the Portable Fire Extinguishers Standard; Extension of the Office of... the information collection requirements contained in the Hydrostatic Testing provision of the Portable... 48729
NASA Technical Reports Server (NTRS)
1984-01-01
A low cost, low power, self-contained portable welding gun designed for joining thermoplastics which become soft when heated and harden when cooled was developed originally by NASA's Langley Research Center for repairing helicopter windshields. Welder has a broad range of applications for joining both thermoplastic materials in the aerospace, automotive, appliance, and construction industries. Welders portability and low power requirement allow its use on-site in any type of climate, with power supplied by a variety of portable sources.
Precise time dissemination via portable atomic clocks
NASA Technical Reports Server (NTRS)
Putkovich, K.
1982-01-01
The most precise operational method of time dissemination over long distances presently available to the Precise Time and Time Interval (PTTI) community of users is by means of portable atomic clocks. The Global Positioning System (GPS), the latest system showing promise of replacing portable clocks for global PTTI dissemination, was evaluated. Although GPS has the technical capability of providing superior world-wide dissemination, the question of present cost and future accessibility may require a continued reliance on portable clocks for a number of years. For these reasons a study of portable clock operations as they are carried out today was made. The portable clock system that was utilized by the U.S. Naval Observatory (NAVOBSY) in the global synchronization of clocks over the past 17 years is described and the concepts on which it is based are explained. Some of its capabilities and limitations are also discussed.
Harper, Martin; Pacolay, Bruce; Hintz, Patrick; Bartley, David L; Slaven, James E; Andrew, Michael E
2007-11-01
This paper concludes a five-year program on research into the use of a portable X-ray fluorescence (XRF) analyzer for analyzing lead in air sampling filters from different industrial environments, including mining, manufacturing and recycling. The results from four of these environments have already been reported. The results from two additional metal processes are presented here. At both of these sites, lead was a minor component of the total airborne metals and interferences from other elements were minimal. Nevertheless, only results from the three sites where lead was the most abundant metal were used in the overall calculation of method accuracy. The XRF analyzer was used to interrogate the filters, which were then subjected to acid digestion and analysis by inductively-coupled plasma optical-emission spectroscopy (ICP-OES). The filter samples were collected using different filter-holders or "samplers" where the size (diameter), depth and homogeneity of aerosol deposit varied from sampler to sampler. The aerosol collection efficiencies of the samplers were expected to differ, especially for larger particles. The distribution of particles once having entered the sampler was also expected to differ between samplers. Samplers were paired to allow the between-sampler variability to be addressed, and, in some cases, internal sampler wall deposits were evaluated and compared to the filter catch. It was found, rather surprisingly, that analysis of the filter deposits (by ICP-OES) of all the samplers gave equivalent results. It was also found that deposits on some of the sampler walls, which in some protocols are considered part of the sample, could be significant in comparison to the filter deposit. If it is concluded that wall-deposits should be analyzed, then XRF analysis of the filter can only give a minimum estimate of the concentration. Techniques for the statistical analysis of field data were also developed as part of this program and have been reported elsewhere. The results, based on data from the three workplaces where lead was the major element present in the samples, are summarized here. A limit of detection and a limit of quantitation are provided. Analysis of some samples using a second analyzer with a different X-ray source technology indicated reasonable agreement for some metals (but this was not evaluated for lead). Provided it is only necessary to analyze the filters, most personal samplers will provide acceptable results when used with portable XRF analysis for lead around applicable limit values.
Installing Portable Classrooms With Good Air Quality.
ERIC Educational Resources Information Center
Godfrey, Ray
2000-01-01
Discusses the advantages of modular classrooms and improvements made in indoor air quality, including the pros and cons of portables, challenges districts face when planning and installing portables, and cost considerations. Concluding comments highlight system costs and maintenance required. (GR)
Portable bathtub: technology for bed bath in bedridden patients.
Backes, Dirce Stein; Gomes, Carine Alves; Pereira, Simone Barbosa; Teles, Noelucy Ferreira; Backes, Marli Terezinha Stein
2017-04-01
determine the benefits of the Portable Bathtub as technology for bed bath in bedridden patients. qualitative research of exploratory-descriptive character, whose data were collected by means of 30 interviews with patients, family members and professionals directly involved in bed bath, carried out with Portable Bathtub, in bedridden patients of a medical clinic, from July to December 2015. from the data encoded by thematic content analysis resulted two categories: Portable Bathtub: from morphine to the patient's rekindled eyes; From mechanized practice to unique, transforming care. we concluded that the Portable Bathtub constitutes enhancing technology, as it enables clinical improvement of the patient's general condition and transcends traditional mechanized practices by the reach of advanced nursing care practices.
Technology assessment of portable energy RDT and P, phase 1
NASA Technical Reports Server (NTRS)
Spraul, J. R. (Compiler)
1975-01-01
A technological assessment of portable energy research, development, technology, and production was undertaken to assess the technical, economic, environmental, and sociopolitical issues associated with portable energy options. Those courses of action are discussed which would impact aviation and air transportation research and technology. Technology assessment workshops were held to develop problem statements. The eighteen portable energy problem statements are discussed in detail along with each program's objective, approach, task description, and estimates of time and costs.
Nickerson, Jillian; Lee, Euny; Nedelman, Michael; Aurora, R Nisha; Krieger, Ana; Horowitz, Carol R
2015-01-01
Portable sleep monitors may offer a convenient method to expand detection of obstructive sleep apnea (OSA), yet few studies have evaluated this technology in vulnerable populations. We therefore aimed to assess the feasibility and acceptability of portable sleep monitors for detection of OSA in a prediabetic, urban minority population. We recruited a convenience sample of participants at their 12-month follow-up for a community-partnered, peer-led lifestyle intervention aimed to prevent diabetes in prediabetic and overweight patients in this prospective mixed-methods pilot study. All participants wore portable sleep monitors overnight at home. We qualitatively explored perceptions about OSA and portable monitors in a subset of participants. We tested 72 people, predominantly non-White, female, Spanish speaking, uninsured, and of low income. Use of portable sleep monitors was feasible: 100% of the monitors were returned and all participants received results. We detected OSA in 49% (defined as an Apnea-Hypopnea Index [AHI] >5) and moderate-severe OSA in 14% (AHI >15) requiring treatment in 14%. In 21 qualitative interviews, participants supported increased use of portable sleep monitors in their community, were appropriately concerned that OSA could cause progression to diabetes, and thought weight loss could prevent or improve OSA. Portable sleep monitors may represent a feasible method for detecting OSA in high-risk urban minority populations. © Copyright 2015 by the American Board of Family Medicine.
Training Laparoscopic Skills at Home: Residents' Opinion of a New Portable Tablet Box Trainer.
van der Aa, Jessica E; Schreuder, Henk W R
2016-04-01
To determine residents' opinion about a new portable box trainer, to see if they would be interested in using this for training at home, and to give an overview of the box trainers that could be used at home. An expert opinion study was performed among 27 gynecology residents to determine the value of the portable box trainer in training their laparoscopic skills and the value of using it at home. Their opinions were scored on a 5-point Likert scale. Gynecology residents very much appreciated the portable box trainer in its design, size, visualization, light source, ability to record, and instruments (all median 4). They felt that the portable box trainer would be effective in training laparoscopic skills in general; in training hand-eye coordination, 3D perception, and tying knots (all median 4); and especially in training basic skills (median 5). Almost all residents would use the portable box trainer if they had one at home (median 5). The literature supports the hypothesis that training laparoscopic skills at home using a box trainer may be effective in acquiring and maintaining laparoscopic skills. Training laparoscopic skills at home using a portable box trainer may be of added value in the laparoscopic training of surgical residents. Residents feel positive about using the new portable box trainer that is presented and appreciate the possibility of training at home. © The Author(s) 2015.
Development of a hybrid molecular beam epitaxy deposition system for in situ surface x-ray studies
NASA Astrophysics Data System (ADS)
Andersen, Tassie K.; Cook, Seyoung; Benda, Erika; Hong, Hawoong; Marks, Laurence D.; Fong, Dillon D.
2018-03-01
A portable metalorganic gas delivery system designed and constructed to interface with an existing molecular beam epitaxy chamber at beamline 33-ID-E of the Advanced Photon Source is described. This system offers the ability to perform in situ X-ray measurements of complex oxide growth via hybrid molecular beam epitaxy. The performance of the hybrid molecular beam epitaxy system while delivering metalorganic source materials is described. The high-energy X-ray scattering capabilities of the hybrid molecular beam epitaxy system are demonstrated both on oxide films grown solely from the metalorganic source and ABO3 oxide perovskites containing elements from both the metalorganic source and a traditional effusion cell.
NASA Astrophysics Data System (ADS)
Khazaaleh, Shadi; Saeed, Numan; Taha, Inas; Madzik, Mateusz T.; Viegas, Jaime
2017-02-01
In this work, we present the experimental results of a new wafer-level production platform for aluminum nitride based piezoelectric micromachined ultrasonic transducers (PMUTs), operated by lower than 10 V peak-to-peak signals, and covering ultrasonic frequency ranges from 200 kHz up to 10 MHz, with measured axial displacements ranging from a few nanometers up to 600 nm. The fabricated devices have a low footprint of (130x130) μm2. The experimental results are in excellent agreement with finite-element method simulations. The small footprint and driving voltages of these piezo-microactuators are well suited for the development of micropump and micromixer designs for portable microfluidics applications.
Differential-damper topologies for actuators in rehabilitation robotics.
Tucker, Michael R; Gassert, Roger
2012-01-01
Differential-damper (DD) elements can provide a high bandwidth means for decoupling a high inertia, high friction, non-backdrivable actuator from its output and can enable high fidelity force control. In this paper, a port-based decomposition is used to analyze the energetic behavior of such actuators in various physical domains. The general concepts are then applied to a prototype DD actuator for illustration and discussion. It is shown that, within physical bounds, the output torque from a DD actuator can be controlled independently from the input speed. This concept holds the potential to be scaled up and integrated in a compact and lightweight package powerful enough for incorporation with a portable lower limb orthotic or prosthetic device.
NASA Technical Reports Server (NTRS)
Chien, Andrew A.; Karamcheti, Vijay; Plevyak, John; Sahrawat, Deepak
1993-01-01
Concurrent object-oriented languages, particularly fine-grained approaches, reduce the difficulty of large scale concurrent programming by providing modularity through encapsulation while exposing large degrees of concurrency. Despite these programmability advantages, such languages have historically suffered from poor efficiency. This paper describes the Concert project whose goal is to develop portable, efficient implementations of fine-grained concurrent object-oriented languages. Our approach incorporates aggressive program analysis and program transformation with careful information management at every stage from the compiler to the runtime system. The paper discusses the basic elements of the Concert approach along with a description of the potential payoffs. Initial performance results and specific plans for system development are also detailed.
Environmental concept for engineering software on MIMD computers
NASA Technical Reports Server (NTRS)
Lopez, L. A.; Valimohamed, K.
1989-01-01
The issues related to developing an environment in which engineering systems can be implemented on MIMD machines are discussed. The problem is presented in terms of implementing the finite element method under such an environment. However, neither the concepts nor the prototype implementation environment are limited to this application. The topics discussed include: the ability to schedule and synchronize tasks efficiently; granularity of tasks; load balancing; and the use of a high level language to specify parallel constructs, manage data, and achieve portability. The objective of developing a virtual machine concept which incorporates solutions to the above issues leads to a design that can be mapped onto loosely coupled, tightly coupled, and hybrid systems.
An update on the BQCD Hybrid Monte Carlo program
NASA Astrophysics Data System (ADS)
Haar, Taylor Ryan; Nakamura, Yoshifumi; Stüben, Hinnerk
2018-03-01
We present an update of BQCD, our Hybrid Monte Carlo program for simulating lattice QCD. BQCD is one of the main production codes of the QCDSF collaboration and is used by CSSM and in some Japanese finite temperature and finite density projects. Since the first publication of the code at Lattice 2010 the program has been extended in various ways. New features of the code include: dynamical QED, action modification in order to compute matrix elements by using Feynman-Hellman theory, more trace measurements (like Tr(D-n) for K, cSW and chemical potential reweighting), a more flexible integration scheme, polynomial filtering, term-splitting for RHMC, and a portable implementation of performance critical parts employing SIMD.
Hermansen, Peter; MacKay, Scott; Wishart, David; Jie Chen
2016-08-01
Microfabricated interdigitated electrode chips have been designed for use in a unique gold-nanoparticle based biosensor system. The use of these electrodes will allow for simple, accurate, inexpensive, and portable biosensing, with potential applications in diagnostics, medical research, and environmental testing. To determine the optimal design for these electrodes, finite element analysis simulations were carried out using COMSOL Multiphysics software. The results of these simulations determined some of the optimal design parameters for microfabricating interdigitated electrodes as well as predicting the effects of different electrode materials. Finally, based on the results of these simulations two different kinds of interdigitated electrode chips were made using photolithography.
A portable infrasound generator.
Park, Joseph; Robertson, James
2009-04-01
The rotary subwoofer is a novel low frequency transducer capable of efficiently generating infrasound from a compact source. A field-deployable version of this device may find application as a calibration source for infrasound arrays of the International Monitoring System (IMS) [(2001). The Global Verification Regime and the International Monitoring System (CTBTO Preparatory Commission Vienna International Centre, Vienna, Austria)]. A prototype tested at the IMS infrasound array I59US demonstrated the ability to insonify all elements of the array from a standoff distance of 3.8 km. Signal-to-noise ratios of continuous wave signals ranged from 5 to 15 dB, indicating the utility of this source to transmit controllable infrasound signals over distances of 5 km.
Optofluidic platforms based on surface-enhanced Raman scattering.
Lim, Chaesung; Hong, Jongin; Chung, Bong Geun; deMello, Andrew J; Choo, Jaebum
2010-05-01
We report recent progress in the development of surface-enhanced Raman scattering (SERS)-based optofluidic platforms for the fast and sensitive detection of chemical and biological analytes. In the current context, a SERS-based optofluidic platform is defined as an integrated analytical device composed of a microfluidic element and a sensitive Raman spectrometer. Optofluidic devices for SERS detection normally involve nanocolloid-based microfluidic systems or metal nanostructure-embedded microfluidic systems. In the current review, recent advances in both approaches are surveyed and assessed. Additionally, integrated real-time sensing systems that combine portable Raman spectrometers with microfluidic devices are also reviewed. Such real-time sensing systems have significant utility in environmental monitoring, forensic science and homeland defense applications.
Developing Standards to Qualify a Fine Water Mist Fire Extinguisher for Human Spaceflight
NASA Technical Reports Server (NTRS)
Graf, John
2011-01-01
NASA is developing a Fine Water Mist Portable Fire Extinguisher for use on the International Space Station. The International Space Station presently uses two different types of fire extinguishers: a water foam extinguisher in the Russian Segment, and a carbon dioxide extinguisher in the US Segment and Columbus and Kibo pressurized elements. Changes in emergency breathing equipment make Fine Water Mist operationally preferable. Supplied oxygen breathing systems allow for safe discharge of a carbon dioxide fire extinguisher, without concerns of the crew inhaling unsafe levels of carbon dioxide. But the Portable Breathing Apparatus offers no more than 15 minutes of capability, and continued use of hose based supplied oxygen systems increases the oxygen content in a fire situation. NASA has developed a filtering respirator cartridge for use in a fire environment. It is qualified to provide up to 90 minutes of capability, and because it is a filtering respirator it does not add oxygen to the environment. The fire response respirator cartridge does not filter carbon dioxide, so a crew member discharging a CO2 fire extinguisher while wearing this filtering respirator would be at risk of inhaling unsafe levels of CO2. Fine Water Mist extinguishes a fire without creating a large volume of air with reduced oxygen and elevated CO2. Compared to the carbon dioxide based Portable Fire Extinguisher, the flight qualification of Fine Water Mist systems requires special care. Qualification of the CO2 based Portable Fire Extinguisher began with the assumption that any fire on ISS would be extinguished if the air in the fire environment reached a critical concentration of CO2. Qualification of a CO2 based system requires the developers to make assertions and assumptions about vehicle geometry and the ability of the extinguisher to deliver CO2 in different geometric configurations, but the developers did not need to make assertions or assumptions about the size of the fire, the temperature, or the heat generation rate. Fine Water Mist systems extinguish a fire predominantly by removing heat -- so qualification standards must evaluate geometry, but also temperature, heat transfer, and heat generation rate. This paper outlines and describes the methods used to develop standards used to qualify Fine Water Mist systems for a human spaceflight environment.
Bagworm bags as portable armour against invertebrate predators
2016-01-01
Some animals have evolved the use of environmental materials as “portable armour” against natural enemies. Portable bags that bagworm larvae (Lepidoptera: Psychidae) construct using their own silk and plant parts are generally believed to play an important role as a physical barrier against natural enemies. However, no experimental studies have tested the importance of bags as portable armour against predators. To clarify the defensive function, I studied the bagworm Eumeta minuscula and a potential predator Calosoma maximoviczi (Coleoptera: Carabidae). Under laboratory conditions, all bagworm larvae were attacked by carabid adults, but successfully defended themselves against the predators’ mandibles using their own bags. The portable bags, which are composed mainly of host plant twigs, may function as a physical barrier against predator mandibles. To test this hypothesis, I removed the twig bags and replaced some with herb leaf bags; all bag-removed larvae were easily caught and predated by carabids, while all bag-replaced larvae could successfully defend themselves against carabid attacks. Therefore, various types of portable bags can protect bagworm larvae from carabid attacks. This is the first study to test the defensive function of bagworm portable bags against invertebrate predators. PMID:26893969
47 CFR 80.271 - Technical requirements for portable survival craft radiotelephone transceivers.
Code of Federal Regulations, 2010 CFR
2010-10-01
... craft radiotelephone transceivers. 80.271 Section 80.271 Telecommunication FEDERAL COMMUNICATIONS... Authorization for Compulsory Ships § 80.271 Technical requirements for portable survival craft radiotelephone transceivers. (a) Portable survival craft radiotelephone transceivers must comply with the following: (1) The...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-06
... INTERNATIONAL TRADE COMMISSION [Docket No 2958] Certain Portable Electronic Communications Devices, Including Mobile Phones and Components Thereof; Correction to Notice of Receipt of Complaint; Solicitation... of complaint entitled Certain Portable Electronic Communications Devices, Including Mobile Phones and...
Portable direct methanol fuel cell systems
NASA Technical Reports Server (NTRS)
Narayanan, S. R.; Valdez, T. I.
2002-01-01
This article includes discussion of the specific power and power density requirements for various portable system applications, the status of stack technology, progress in the implementation of balance-of-plant designs, and a summary of the characteristics of various DMFC portable power source demonstrations.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-03-19
... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-794] Certain Electronic Devices, Including Wireless Communication Devices, Portable Music and Data Processing Devices, and Tablet Computers... certain electronic devices, including wireless communication devices, portable music and data processing...
Code of Federal Regulations, 2010 CFR
2010-10-01
...: SPECIFICATIONS AND APPROVAL LIFESAVING EQUIPMENT Magazine Chests, Portable, for Merchant Vessels § 160.038-5 Marking. (a) Portable magazine chests used for the stowage of pyrotechnic signals, rockets, and powder for...: “Portable Magazine Chest, Inflammable—Keep Lights and Fire Away.” (b) [Reserved] ...
NASA Technical Reports Server (NTRS)
Weddendorf, Bruce (Inventor)
1994-01-01
A portable seat lift that can help individuals either (1) lower themselves to a sitting position or (2) raise themselves to a standing position is presented. The portable seat lift consists of a seat mounted on a base with two levers, which are powered by a drive unit.
The Economics of Educational Software Portability.
ERIC Educational Resources Information Center
Oliveira, Joao Batista Araujo e
1990-01-01
Discusses economic issues that affect the portability of educational software. Topics discussed include economic reasons for portability, including cost effectiveness; the nature and behavior of educational computer software markets; the role of producers, buyers, and consumers; potential effects of government policies; computer piracy; and…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gałuszka, Agnieszka, E-mail: Agnieszka.Galuszka@ujk.edu.pl; Migaszewski, Zdzisław M.; Namieśnik, Jacek
The recent rapid progress in technology of field portable instruments has increased their applications in environmental sample analysis. These instruments offer a possibility of cost-effective, non-destructive, real-time, direct, on-site measurements of a wide range of both inorganic and organic analytes in gaseous, liquid and solid samples. Some of them do not require the use of reagents and do not produce any analytical waste. All these features contribute to the greenness of field portable techniques. Several stationary analytical instruments have their portable versions. The most popular ones include: gas chromatographs with different detectors (mass spectrometer (MS), flame ionization detector, photoionization detector),more » ultraviolet–visible and near-infrared spectrophotometers, X-ray fluorescence spectrometers, ion mobility spectrometers, electronic noses and electronic tongues. The use of portable instruments in environmental sample analysis gives a possibility of on-site screening and a subsequent selection of samples for routine laboratory analyses. They are also very useful in situations that require an emergency response and for process monitoring applications. However, quantification of results is still problematic in many cases. The other disadvantages include: higher detection limits and lower sensitivity than these obtained in laboratory conditions, a strong influence of environmental factors on the instrument performance and a high possibility of sample contamination in the field. This paper reviews recent applications of field portable instruments in environmental sample analysis and discusses their analytical capabilities. - Highlights: • Field portable instruments are widely used in environmental sample analysis. • Field portable instruments are indispensable for analysis in emergency response. • Miniaturization of field portable instruments reduces resource consumption. • In situ analysis is in agreement with green analytical chemistry principles. • Performance requirements in field analysis stimulate technological progress.« less
Advances in Materials and System Technology for Portable Fuel Cells
NASA Technical Reports Server (NTRS)
Narayanan, Sekharipuram R.
2007-01-01
This viewgraph presentation describes the materials and systems engineering used for portable fuel cells. The contents include: 1) Portable Power; 2) Technology Solution; 3) Portable Hydrogen Systems; 4) Direct Methanol Fuel Cell; 5) Direct Methanol Fuel Cell System Concept; 6) Overview of DMFC R&D at JPL; 7) 300-Watt Portable Fuel Cell for Army Applications; 8) DMFC units from Smart Fuel Cell Inc, Germany; 9) DMFC Status and Prospects; 10) Challenges; 11) Rapid Screening of Well-Controlled Catalyst Compositions; 12) Screening of Ni-Zr-Pt-Ru alloys; 13) Issues with New Membranes; 14) Membranes With Reduced Methanol Crossover; 15) Stacks; 16) Hybrid DMFC System; 17) Small Compact Systems; 18) Durability; and 19) Stack and System Parameters for Various Applications.
46 CFR 162.028-7 - Procedure for listing and labeling.
Code of Federal Regulations, 2010 CFR
2010-10-01
... and motorboats may make application for listing and labeling as a marine-type portable fire..., AND MATERIALS: SPECIFICATIONS AND APPROVAL ENGINEERING EQUIPMENT Extinguishers, Fire, Portable, Marine Type § 162.028-7 Procedure for listing and labeling. (a) Manufacturers having a marine-type portable...
40 CFR 59.660 - Exemption from the standards.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Control of Evaporative Emissions From New and In-Use Portable Fuel Containers Special Compliance Provisions § 59.660 Exemption from the standards. In certain circumstances, we may exempt portable fuel.... Submit your request for an exemption to the Designated Compliance Officer. (a) Portable fuel containers...
David Anna
2017-12-09
The National Energy Technology Laboratory developed the idea of a portable joint information center AKA JIC in-a-box. This video discribes some of the equipment in the portable JIC as well as some of the methodology that NETL developed as a result of this portable JIC concept.
30 CFR 75.1703 - Portable electric lamps.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Portable electric lamps. 75.1703 Section 75... HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Miscellaneous § 75.1703 Portable electric lamps. [Statutory Provisions] Persons underground shall use only permissible electric lamps approved by the...
30 CFR 75.1703 - Portable electric lamps.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Portable electric lamps. 75.1703 Section 75... HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Miscellaneous § 75.1703 Portable electric lamps. [Statutory Provisions] Persons underground shall use only permissible electric lamps approved by the...
30 CFR 75.1703 - Portable electric lamps.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Portable electric lamps. 75.1703 Section 75... HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Miscellaneous § 75.1703 Portable electric lamps. [Statutory Provisions] Persons underground shall use only permissible electric lamps approved by the...
30 CFR 75.1703 - Portable electric lamps.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Portable electric lamps. 75.1703 Section 75... HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Miscellaneous § 75.1703 Portable electric lamps. [Statutory Provisions] Persons underground shall use only permissible electric lamps approved by the...
30 CFR 75.1703 - Portable electric lamps.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Portable electric lamps. 75.1703 Section 75... HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Miscellaneous § 75.1703 Portable electric lamps. [Statutory Provisions] Persons underground shall use only permissible electric lamps approved by the...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-04
... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-794] Certain Electronic Devices, Including Wireless Commmunication Devices, Portable Music and Data Processing Devices, and Tablet Computers... communication devices, portable music and data processing devices, and tablet computers, imported by Apple Inc...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-26
... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-745] Certain Wireless Communication Devices, Portable Music and Data Processing Devices, Computers and Components Thereof; Commission Decision... importation of certain wireless communication devices, portable music and data processing devices, computers...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-02-25
... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-745] Certain Wireless Communication Devices, Portable Music and Data Processing Devices, Computers and Components Thereof; Commission Decision... importation of certain wireless communication devices, portable music and data processing devices, computers...
Portable Tablets in Science Museum Learning: Options and Obstacles
NASA Astrophysics Data System (ADS)
Gronemann, Sigurd Trolle
2017-06-01
Despite the increasing use of portable tablets in learning, their impact has received little attention in research. In five different projects, this media-ethnographic and design-based analysis of the use of portable tablets as a learning resource in science museums investigates how young people's learning with portable tablets matches the intentions of the museums. By applying media and information literacy (MIL) components as analytical dimensions, a pattern of discrepancies between young people's expectations, their actual learning and the museums' approaches to framing such learning is identified. It is argued that, paradoxically, museums' decisions to innovate by introducing new technologies, such as portable tablets, and new pedagogies to support them conflict with many young people's traditional ideas of museums and learning. The assessment of the implications of museums' integration of portable tablets indicates that in making pedagogical transformations to accommodate new technologies, museums risk opposing didactic intention if pedagogies do not sufficiently attend to young learners' systemic expectations to learning and to their expectations to the digital experience influenced by their leisure use.
Solid Sampling with a Diode Laser for Portable Ambient Mass Spectrometry
2017-01-01
A hand-held diode laser is implemented for solid sampling in portable ambient mass spectrometry (MS). Specifically, a pseudocontinuous wave battery-powered surgical laser diode is employed for portable laser diode thermal desorption (LDTD) at 940 nm and compared with nanosecond pulsed laser ablation at 2940 nm. Postionization is achieved in both cases using atmospheric pressure photoionization (APPI). The laser ablation atmospheric pressure photoionization (LAAPPI) and LDTD-APPI mass spectra of sage leaves (Salvia officinalis) using a field-deployable quadrupole ion trap MS display many similar ion peaks, as do the mass spectra of membrane grown biofilms of Pseudomonas aeruginosa. These results indicate that LDTD-APPI method should be useful for in-field sampling of plant and microbial communities, for example, by portable ambient MS. The feasibility of many portable MS applications is facilitated by the availability of relatively low cost, portable, battery-powered diode lasers. LDTD could also be coupled with plasma- or electrospray-based ionization for the analysis of a variety of solid samples. PMID:28632988
Solid Sampling with a Diode Laser for Portable Ambient Mass Spectrometry.
Yung, Yeni P; Wickramasinghe, Raveendra; Vaikkinen, Anu; Kauppila, Tiina J; Veryovkin, Igor V; Hanley, Luke
2017-07-18
A hand-held diode laser is implemented for solid sampling in portable ambient mass spectrometry (MS). Specifically, a pseudocontinuous wave battery-powered surgical laser diode is employed for portable laser diode thermal desorption (LDTD) at 940 nm and compared with nanosecond pulsed laser ablation at 2940 nm. Postionization is achieved in both cases using atmospheric pressure photoionization (APPI). The laser ablation atmospheric pressure photoionization (LAAPPI) and LDTD-APPI mass spectra of sage leaves (Salvia officinalis) using a field-deployable quadrupole ion trap MS display many similar ion peaks, as do the mass spectra of membrane grown biofilms of Pseudomonas aeruginosa. These results indicate that LDTD-APPI method should be useful for in-field sampling of plant and microbial communities, for example, by portable ambient MS. The feasibility of many portable MS applications is facilitated by the availability of relatively low cost, portable, battery-powered diode lasers. LDTD could also be coupled with plasma- or electrospray-based ionization for the analysis of a variety of solid samples.