Sample records for element facility risk

  1. Societal-Equity-Enhancing Criteria and Facility-Host Incentives Supporting Five Key Elements in the January 2012 Blue Ribbon Commission Report - 13015

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eriksson, Leif G.; Dials, George E.; George, Critz H.

    2013-07-01

    In February 2009, the Obama Administration announced it would abandon USA's only candidate SNF/HLW-disposal facility since 1987. In 2010, all related activities were stopped and the Blue Ribbon Commission on America's Nuclear Future was established 'to recommend a new strategy for managing the back end of the nuclear fuel cycle', which it did in January 2012, emphasizing eight key elements. However, Key Element 1, 'A new, consent-based approach to siting future nuclear facilities', is qualitative/indeterminate rather than quantitative/measurable. It is thus highly-susceptible to semantic permutations that could extend rather than, as intended, expedite the siting of future nuclear facilities unlessmore » it also defines: a) Whose consent is needed?; and b) What constitutes consent? The following 'generic', radiation-risk- and societal-equity-based criteria address these questions: 1. Identify areas affected by projected radiation and other health risks from: a. The proposed nuclear facility (facility stakeholders); and b. The related nuclear-materials-transportation routes (transportation stakeholders); then 2. Surround each stakeholder area with a buffer zone and use this enlarged foot print to identify: a. Stakeholder hosts; and b. Areas not hosting any stakeholder category (interested parties). 3. Define 'consent-based' as being at least 60 percent of the 'population' in the respective stakeholder category and apply this yardstick to both 'in favor' and 'against' votes. Although criteria 1 and 2 also need facility-based definitions to make Key Element 1 measurable, the described siting approach, augmented by related facility-host incentives, would expedite the schedule and reduce the cost for achieving Key Elements 4-6 and 8, politics permitting. (authors)« less

  2. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yates, K.R.; Schreiber, A.M.; Rudolph, A.W.

    The US Nuclear Regulatory Commission has initiated the Fuel Cycle Risk Assessment Program to provide risk assessment methods for assistance in the regulatory process for nuclear fuel cycle facilities other than reactors. Both the once-through cycle and plutonium recycle are being considered. A previous report generated by this program defines and describes fuel cycle facilities, or elements, considered in the program. This report, the second from the program, describes the survey and computer compilation of fuel cycle risk-related literature. Sources of available information on the design, safety, and risk associated with the defined set of fuel cycle elements were searchedmore » and documents obtained were catalogued and characterized with respect to fuel cycle elements and specific risk/safety information. Both US and foreign surveys were conducted. Battelle's computer-based BASIS information management system was used to facilitate the establishment of the literature compilation. A complete listing of the literature compilation and several useful indexes are included. Future updates of the literature compilation will be published periodically. 760 annotated citations are included.« less

  3. Quantitative Estimation of Risks for Production Unit Based on OSHMS and Process Resilience

    NASA Astrophysics Data System (ADS)

    Nyambayar, D.; Koshijima, I.; Eguchi, H.

    2017-06-01

    Three principal elements in the production field of chemical/petrochemical industry are (i) Production Units, (ii) Production Plant Personnel and (iii) Production Support System (computer system introduced for improving productivity). Each principal element has production process resilience, i.e. a capability to restrain disruptive signals occurred in and out of the production field. In each principal element, risk assessment is indispensable for the production field. In a production facility, the occupational safety and health management system (Hereafter, referred to as OSHMS) has been introduced to reduce a risk of accidents and troubles that may occur during production. In OSHMS, a risk assessment is specified to reduce a potential risk in the production facility such as a factory, and PDCA activities are required for a continual improvement of safety production environments. However, there is no clear statement to adopt the OSHMS standard into the production field. This study introduces a metric to estimate the resilience of the production field by using the resilience generated by the production plant personnel and the result of the risk assessment in the production field. A method for evaluating how OSHMS functions are systematically installed in the production field is also discussed based on the resilience of the three principal elements.

  4. Security culture for nuclear facilities

    NASA Astrophysics Data System (ADS)

    Gupta, Deeksha; Bajramovic, Edita

    2017-01-01

    Natural radioactive elements are part of our environment and radioactivity is a natural phenomenon. There are numerous beneficial applications of radioactive elements (radioisotopes) and radiation, starting from power generation to usages in medical, industrial and agriculture applications. But the risk of radiation exposure is always attached to operational workers, the public and the environment. Hence, this risk has to be assessed and controlled. The main goal of safety and security measures is to protect human life, health, and the environment. Currently, nuclear security considerations became essential along with nuclear safety as nuclear facilities are facing rapidly increase in cybersecurity risks. Therefore, prevention and adequate protection of nuclear facilities from cyberattacks is the major task. Historically, nuclear safety is well defined by IAEA guidelines while nuclear security is just gradually being addressed by some new guidance, especially the IAEA Nuclear Security Series (NSS), IEC 62645 and some national regulations. At the overall level, IAEA NSS 7 describes nuclear security as deterrence and detection of, and response to, theft, sabotage, unauthorized access, illegal transfer or other malicious acts involving nuclear, other radioactive substances and their associated facilities. Nuclear security should be included throughout nuclear facilities. Proper implementation of a nuclear security culture leads to staff vigilance and a high level of security posture. Nuclear security also depends on policy makers, regulators, managers, individual employees and members of public. Therefore, proper education and security awareness are essential in keeping nuclear facilities safe and secure.

  5. Identification of elements at risk for a credible tsunami event for Istanbul

    NASA Astrophysics Data System (ADS)

    Hancilar, U.

    2012-01-01

    Physical and social elements at risk are identified for a credible tsunami event for Istanbul. For this purpose, inundation maps resulting from probabilistic tsunami hazard analysis for a 10% probability of exceedance in 50 yr are utilised in combination with the geo-coded inventories of building stock, lifeline systems and demographic data. The built environment on Istanbul's shorelines that is exposed to tsunami inundation comprises residential, commercial, industrial, public (governmental/municipal, schools, hospitals, sports and religious), infrastructure (car parks, garages, fuel stations, electricity transformer buildings) and military buildings, as well as piers and ports, gas tanks and stations and other urban elements (e.g., recreational facilities). Along the Marmara Sea shore, Tuzla shipyards and important port and petrochemical facilities at Ambarlı are expected to be exposed to tsunami hazard. Significant lifeline systems of the city of Istanbul such as natural gas, electricity, telecommunication and sanitary and waste-water transmission, are also under the threat of tsunamis. In terms of social risk, it is estimated that there are about 32 000 inhabitants exposed to tsunami hazard.

  6. LLRW disposal facility siting approaches: Connecticut`s innovative volunteer approach

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Forcella, D.; Gingerich, R.E.; Holeman, G.R.

    1994-12-31

    The Connecticut Hazardous Waste Management Service (CHWMS) has embarked on a volunteer approach to siting a LLRW disposal facility in Connecticut. This effort comes after an unsuccessful effort to site a facility using a step-wise, criteria-based site screening process that was a classic example of the decide/announce/defend approach. While some of the specific features of the CHWMS` volunteer process reflect the unique challenge presented by the state`s physical characteristics, political structure and recent unsuccessful siting experience, the basic elements of the process are applicable to siting LLRW disposal facilities in many parts of the United States. The CHWMS` volunteer processmore » is structured to reduce the {open_quotes}outrage{close_quotes} dimension of two of the variables that affect the public`s perception of risk. The two variables are the degree to which the risk is taken on voluntarily (voluntary risks are accepted more readily than those that are imposed) and the amount of control one has over the risk (risks under individual control are accepted more readily than those under government control). In the volunteer process, the CHWMS will only consider sites that have been been voluntarily offered by the community in which they are located and the CHWMS will share control over the development and operation of the facility with the community. In addition to these elements which have broad applicability, the CHWMS has tailored the volunteer approach to take advantage of the unique opportunities made possible by the earlier statewide site screening process. Specifically, the approach presents a {open_quotes}win-win{close_quotes} situation for elected officials in many communities if they decide to participate in the process.« less

  7. Workplace Violence Training Programs for Health Care Workers: An Analysis of Program Elements.

    PubMed

    Arbury, Sheila; Hodgson, Michael; Zankowski, Donna; Lipscomb, Jane

    2017-06-01

    Commercial workplace violence (WPV) prevention training programs differ in their approach to violence prevention and the content they present. This study reviews 12 such programs using criteria developed from training topics in the Occupational Safety and Health Administration's (OSHA) Guidelines for Preventing Workplace Violence for Healthcare and Social Service Workers and a review of the WPV literature. None of the training programs addressed all the review criteria. The most significant gap in content was the lack of attention to facility-specific risk assessment and policies. To fill this gap, health care facilities should supplement purchased training programs with specific training in organizational policies and procedures, emergency action plans, communication, facility risk assessment, and employee post-incident debriefing and monitoring. Critical to success is a dedicated program manager who understands risk assessment, facility clinical operations, and program management and evaluation.

  8. [Risk management of hospital infections as a supporting tool for the improvement of hospital quality - some European examples].

    PubMed

    Sitek, Mateusz; Witczak, Izabela; Kiedik, Dorota

    Prevention and control of nosocomial infections is one of the main pillars of security in each medical facility. This affects the quality of services and helps to minimize the economic losses incurred as a result of such infections. (Prolonged hospitalization, expensive antibiotic therapies, court costs of damages). Nosocomial infections occur in every medical facility in the hospitals in terms of risk of infection compared to other medicinal entities are at greater risk of environmental (number of hospitalizations for one bed, the amount of disinfectants, etc.). The number and diverse category of employment of medical and auxiliary, which should meet certain standards for the prevention of hospital infections, has an impact on the incidence of infection. It is impossible to eliminate hospital-acquired infections, but can be limited by appropriate measures, ranging from monitoring through the use of risk management methods, which are one of the elements supporting the improvement of the quality of medical entities. Hospital infection is a threat not only for patients but also for workers exposed to the risk of so-called occupational exposure. A comprehensive approach including elements of active surveillance and effective monitoring can help to minimize the risk of nosocomial infections.

  9. Taking Risk Assessment and Management to the Next Level: Program-Level Risk Analysis to Enable Solid Decision-Making on Priorities and Funding

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nelson, J. G.; Morton, R. L.; Castillo, C.

    2011-02-01

    A multi-level (facility and programmatic) risk assessment was conducted for the facilities in the Nevada National Security Site (NNSS) Readiness in Technical Base and Facilities (RTBF) Program and results were included in a new Risk Management Plan (RMP), which was incorporated into the fiscal year (FY) 2010 Integrated Plans. Risks, risk events, probability, consequence(s), and mitigation strategies were identified and captured, for most scope areas (i.e., risk categories) during the facilitated risk workshops. Risk mitigations (i.e., efforts in addition to existing controls) were identified during the facilitated risk workshops when the risk event was identified. Risk mitigation strategies fell intomore » two broad categories: threats or opportunities. Improvement projects were identified and linked to specific risks they mitigate, making the connection of risk reduction through investments for the annual Site Execution Plan. Due to the amount of that was collected, analysis to be performed, and reports to be generated, a Risk Assessment/ Management Tool (RAMtool) database was developed to analyze the risks in real-time, at multiple levels, which reinforced the site-level risk management process and procedures. The RAMtool database was developed and designed to assist in the capturing and analysis of the key elements of risk: probability, consequence, and impact. The RAMtool calculates the facility-level and programmatic-level risk factors to enable a side-by-side comparison to see where the facility manager and program manager should focus their risk reduction efforts and funding. This enables them to make solid decisions on priorities and funding to maximize the risk reduction. A more active risk management process was developed where risks and opportunities are actively managed, monitored, and controlled by each facility more aggressively and frequently. risk owners have the responsibility and accountability to manage their assigned risk in real-time, using the RAMtool database.« less

  10. Elemental Concentrations in Urban Green Stormwater Infrastructure Soils.

    PubMed

    Kondo, Michelle C; Sharma, Raghav; Plante, Alain F; Yang, Yunwen; Burstyn, Igor

    2016-01-01

    Green stormwater infrastructure (GSI) is designed to capture stormwater for infiltration, detention, evapotranspiration, or reuse. Soils play a key role in stormwater interception at these facilities. It is important to assess whether contamination is occurring in GSI soils because urban stormwater drainage areas often accumulate elements of concern. Soil contamination could affect hydrologic and ecosystem functions. Maintenance workers and the public may also be exposed to GSI soils. We investigated soil elemental concentrations, categorized as macro- and micronutrients, heavy metals, and other elements, at 59 GSI sites in the city of Philadelphia. Non-GSI soil samples 3 to 5 m upland of GSI sites were used for comparison. We evaluated differences in elemental composition in GSI and non-GSI soils; the comparisons were corrected for the age of GSI facility, underlying soil type, street drainage, and surrounding land use. Concentrations of Ca and I were greater than background levels at GSI sites. Although GSI facilities appear to accumulate Ca and I, these elements do not pose a significant human health risk. Elements of concern to human health, including Cd, Hg, and Pb, were either no different or were lower in GSI soils compared with non-GSI soils. However, mean values found across GSI sites were up to four times greater than soil cleanup objectives for residential use. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.

  11. Risk assessment for physical and cyber attacks on critical infrastructures.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smith, Bryan J.; Sholander, Peter E.; Phelan, James M.

    2005-08-01

    Assessing the risk of malevolent attacks against large-scale critical infrastructures requires modifications to existing methodologies. Existing risk assessment methodologies consider physical security and cyber security separately. As such, they do not accurately model attacks that involve defeating both physical protection and cyber protection elements (e.g., hackers turning off alarm systems prior to forced entry). This paper presents a risk assessment methodology that accounts for both physical and cyber security. It also preserves the traditional security paradigm of detect, delay and respond, while accounting for the possibility that a facility may be able to recover from or mitigate the results ofmore » a successful attack before serious consequences occur. The methodology provides a means for ranking those assets most at risk from malevolent attacks. Because the methodology is automated the analyst can also play 'what if with mitigation measures to gain a better understanding of how to best expend resources towards securing the facilities. It is simple enough to be applied to large infrastructure facilities without developing highly complicated models. Finally, it is applicable to facilities with extensive security as well as those that are less well-protected.« less

  12. OEM Emergency Prevention and Mitigation Information

    EPA Pesticide Factsheets

    The Office of Emergency Management maintains information relevant to preventing emergencies before they occur, and/or mitigating the effects of emergency when they do occur. A principal element of this data asset is the information managed by the System for Risk Management Plans (SRMP), which compiles risk management plans submitted by facilities in accordance with the Clean Air Act, Section 112(r). Affected facilities are to develop risk management programs which will prevent and minimize consequences of accidental releases of certain hazardous chemicals that could harm public health and the environment.Another component of this data asset are the results generated by the Priority Assessment Model (PAM), which analyzes information concerning low-level chronic emissions from facilities and sets priorities (low, medium, high) for proactive controls on releases that do not necessarily pose imminent threats, but which may under adverse circumstances create unacceptable health or ecological risks.Also included are inspection records compiled by the Oil Inspection Program. Under the Clean Water Act Section 311, EPA regulates oil storage that meets a specific regulatory threshold. Facilities that store oil and meet the regulatory threshold need to prepare and implement a Spill Prevention, Control, and Countermeasures (SPCC) Plan which needs to be reviewed and approved by a professional engineer. Additionally, facilities with larger oil storage capacity may have to pre

  13. Injector element characterization methodology

    NASA Technical Reports Server (NTRS)

    Cox, George B., Jr.

    1988-01-01

    Characterization of liquid rocket engine injector elements is an important part of the development process for rocket engine combustion devices. Modern nonintrusive instrumentation for flow velocity and spray droplet size measurement, and automated, computer-controlled test facilities allow rapid, low-cost evaluation of injector element performance and behavior. Application of these methods in rocket engine development, paralleling their use in gas turbine engine development, will reduce rocket engine development cost and risk. The Alternate Turbopump (ATP) Hot Gas Systems (HGS) preburner injector elements were characterized using such methods, and the methodology and some of the results obtained will be shown.

  14. [Information and facilities recommendations concerning trial of labour in the context of scarred womb].

    PubMed

    Gallot, D; Delabaere, A; Desvignes, F; Vago, C; Accoceberry, M; Lémery, D

    2012-12-01

    To precise key elements concerning facilities and patient information prior to trial of labour in the context of scarred womb. Bibliographic search restricted to French and English languages using Medline database and recommendations of medical societies. Only expert's opinions are available. Patient information should present both trial of labour and elective cesarean section. Counselling should be influenced by individual risk of failed vaginal birth and uterine rupture. Mode of delivery should be planned the latest at 8 months of gestation. Patient should be aware of obstetrical and anesthetic facilities. Trial of labour should be presented as the first option for patients with no additional risk factors. Immediate presence of obstetrician and anesthesiologist is not required except in the context of increased risk for failed trial of labour or uterine rupture. Elective cesarean section on maternal request is acceptable after extensive counselling and delay of reflexion. Individual patient information should be initiated early and mode of delivery should be planned at 8 months of gestation. Resources and facilities recommendations aim to facilitate prompt cesarean section. Copyright © 2012 Elsevier Masson SAS. All rights reserved.

  15. A Strategy to Safely Live and Work in the Space Radiation Environment

    NASA Technical Reports Server (NTRS)

    Corbin, Barbara J.; Sulzman, Frank M.; Krenek, Sam

    2006-01-01

    The goal of the National Aeronautics and Space Agency and the Space Radiation Project is to ensure that astronauts can safely live and work in the space radiation environment. The space radiation environment poses both acute and chronic risks to crew health and safety, but unlike some other aspects of space travel, space radiation exposure has clinically relevant implications for the lifetime of the crew. The term safely means that risks are sufficiently understood such that acceptable limits on mission, post-mission and multi-mission consequences (for example, excess lifetime fatal cancer risk) can be defined. The Space Radiation Project strategy has several elements. The first element is to use a peer-reviewed research program to increase our mechanistic knowledge and genetic capabilities to develop tools for individual risk projection, thereby reducing our dependency on epidemiological data and population-based risk assessment. The second element is to use the NASA Space Radiation Laboratory to provide a ground-based facility to study the understanding of health effects/mechanisms of damage from space radiation exposure and the development and validation of biological models of risk, as well as methods for extrapolation to human risk. The third element is a risk modeling effort that integrates the results from research efforts into models of human risk to reduce uncertainties in predicting risk of carcinogenesis, central nervous system damage, degenerative tissue disease, and acute radiation effects. To understand the biological basis for risk, we must also understand the physical aspects of the crew environment. Thus the fourth element develops computer codes to predict radiation transport properties, evaluate integrated shielding technologies and provide design optimization recommendations for the design of human space systems. Understanding the risks and determining methods to mitigate the risks are keys to a successful radiation protection strategy.

  16. A developmental perspective on high power laser facility technology for ICF

    NASA Astrophysics Data System (ADS)

    Zhu, Jianqiang; Sun, Mingying; Liu, Chong; Guo, Yajing; Yang, Lin; Yang, Pengqian; Zhang, Yanli; Wang, Bingyan; Liu, Cheng; Li, Yangshuai; Ren, Zhiyuan; Liu, Dean; Liu, Zhigang; Jiao, Zhaoyang; Ren, Lei; Zhang, Guowen; Fan, Quantang; Feng, Tao; Lin, Zunqi

    2018-02-01

    The latest progress on high power laser facilities in NLHPLP was reported. Based on a high power laser prototype, damage behavior of 3ω optics was experimentally tested, and the key influencing factors contributed to laser-induced damage in optics were deeply analyzed. The latest experimental results of advanced precision measurement for optical quality applied in the high power laser facility were introduced. At last, based on the accumulated works of 3ω elements damage behavior status in our laboratory, beam expanding scheme was presented to increase the total maximum output 3ω energy properly and decrease the laser induced damage risking of ω optics simultaneously.

  17. Potential metal recovery from waste streams

    USGS Publications Warehouse

    Smith, Kathleen S.; Hageman, Philip L.; Plumlee, Geoffrey S.; Budahn, James R.; Bleiwas, Donald I.

    2015-01-01

    ‘Waste stream’ is a general term that describes the total flow of waste from homes, businesses, industrial facilities, and institutions that are recycled, burned or isolated from the environment in landfills or other types of storage, or dissipated into the environment. The recovery and reuse of chemical elements from waste streams have the potential to decrease U.S. reliance on primary resources and imports, and to lessen unwanted dispersion of some potentially harmful elements into the environment. Additional benefits might include reducing disposal or treatment costs and decreasing the risk of future environmental liabilities for waste generators. Elemental chemistry and mineralogical residences of the elements are poorly documented for many types of waste streams.

  18. NASA Strategy to Safely Live and Work in the Space Radiation Environment

    NASA Technical Reports Server (NTRS)

    Cucinotta, Francis A.; Wu, Honglu; Corbin, Barbara J.; Sulzman, Frank M.; Krenek, Sam

    2007-01-01

    In space, astronauts are constantly bombarded with energetic particles. The goal of the National Aeronautics and Space Agency and the NASA Space Radiation Project is to ensure that astronauts can safely live and work in the space radiation environment. The space radiation environment poses both acute and chronic risks to crew health and safety, but unlike some other aspects of space travel, space radiation exposure has clinically relevant implications for the lifetime of the crew. Among the identified radiation risks are cancer, acute and late CNS damage, chronic and degenerative tissue decease, and acute radiation syndrome. The term "safely" means that risks are sufficiently understood such that acceptable limits on mission, post-mission and multi-mission consequences can be defined. The NASA Space Radiation Project strategy has several elements. The first element is to use a peer-reviewed research program to increase our mechanistic knowledge and genetic capabilities to develop tools for individual risk projection, thereby reducing our dependency on epidemiological data and population-based risk assessment. The second element is to use the NASA Space Radiation Laboratory to provide a ground-based facility to study the health effects/mechanisms of damage from space radiation exposure and the development and validation of biological models of risk, as well as methods for extrapolation to human risk. The third element is a risk modeling effort that integrates the results from research efforts into models of human risk to reduce uncertainties in predicting the identified radiation risks. To understand the biological basis for risk, we must also understand the physical aspects of the crew environment. Thus, the fourth element develops computer algorithms to predict radiation transport properties, evaluate integrated shielding technologies and provide design optimization recommendations for the design of human space systems. Understanding the risks and determining methods to mitigate the risks are keys to a successful radiation protection strategy.

  19. Autonomous rendezvous and capture development infrastructure

    NASA Technical Reports Server (NTRS)

    Bryan, Thomas C.; Roe, Fred; Coker, Cindy; Nelson, Pam; Johnson, B.

    1991-01-01

    In the development of the technology for autonomous rendezvous and docking, key infrastructure capabilities must be used for effective and economical development. This involves facility capabilities, both equipment and personnel, to devise, develop, qualify, and integrate ARD elements and subsystems into flight programs. One effective way of reducing technical risks in developing ARD technology is the use of the ultimate test facility, using a Shuttle-based reusable free-flying testbed to perform a Technology Demonstration Test Flight which can be structured to include a variety of additional sensors, control schemes, and operational approaches. This conceptual testbed and flight demonstration will be used to illustrate how technologies and facilities at MSFC can be used to develop and prove an ARD system.

  20. Increasing the provision of preventive care by community healthcare services: a stepped wedge implementation trial.

    PubMed

    Wiggers, John; McElwaine, Kathleen; Freund, Megan; Campbell, Libby; Bowman, Jenny; Wye, Paula; Wolfenden, Luke; Tremain, Danika; Barker, Daniel; Slattery, Carolyn; Gillham, Karen; Bartlem, Kate

    2017-08-22

    Although clinical guidelines recommend the provision of care to reduce client chronic disease risk behaviours, such care is provided sub-optimally by primary healthcare providers. A study was undertaken to determine the effectiveness of an intervention in increasing community-based clinician implementation of multiple elements of recommended preventive care for four risk behaviours. A three-group stepped-wedge trial was undertaken with all 56 community-based primary healthcare facilities in one health district in New South Wales, Australia. A 12-month implementation intervention was delivered sequentially in each of three geographically and administratively defined groups of facilities. The intervention consisted of six key strategies: leadership and consensus processes, enabling systems, educational meetings and training, audit and feedback, practice change support, and practice change information and resources. Client-reported receipt of three elements of preventive care: assessment; brief advice; referral for four behavioural risks: smoking, inadequate fruit and/or vegetable consumption, alcohol overconsumption, and physical inactivity, individually, and for all such risks combined were collected for 56 months (October 2009-May 2014). Segmented logistic regression models were developed to assess intervention effectiveness. A total of 5369 clients participated in data collection. Significant increases were found for receipt of four of five assessment outcomes (smoking OR 1.53; fruit and/or vegetable intake OR 2.18; alcohol consumption OR 1.69; all risks combined OR 1.78) and two of five brief advice outcomes (fruit and/or vegetable intake OR 2.05 and alcohol consumption OR 2.64). No significant increases in care delivery were observed for referral for any risk behaviour, or for physical inactivity. The implementation intervention was effective in enhancing assessment of client risk status but less so for elements of care that could reduce client risk: provision of brief advice and referral. The intervention was ineffective in increasing care addressing physical inactivity. Further research is required to identify barriers to the provision of preventive care and the effectiveness of practice change interventions in increasing its provision. Australian Clinical Trials Registry ACTRN12611001284954 . Registered 15 December 2011. Retrospectively registered.

  1. Autonomous rendezvous and capture development infrastructure

    NASA Technical Reports Server (NTRS)

    Bryan, Thomas C.

    1991-01-01

    In the development of the technology for autonomous rendezvous and docking, key infrastructure capabilities must be used for effective and economical development. This need involves facility capabilities, both equipment and personnel, to devise, develop, qualify, and integrate ARD elements and subsystems into flight programs. One effective way of reducing technical risks in developing ARD technology is the use of the Low Earth Orbit test facility. Using a reusable free-flying testbed carried in the Shuttle, as a technology demonstration test flight, can be structured to include a variety of sensors, control schemes, and operational approaches. This testbed and flight demonstration concept will be used to illustrate how technologies and facilities at MSFC can be used to develop and prove an ARD system.

  2. The relationship between the availability of the supporting elements of pedestrian with pedestrian crossing facility usage based on user preferences (Case Study corridor of Sumbersari Street, Gajayana Street, MT. Haryono Street, Malang City)

    NASA Astrophysics Data System (ADS)

    Soetrisno, D. P.

    2017-06-01

    Pedestrian crossing facilities are effective enough to avoid pedestrians with vehicles, but its utilization is still quite low. It indicated that safety is not the only factor that influences a person to utilize the pedestrian crossing facilities. In addition, the availability of supporting elements of the pedestrian is still not quite attention, which is also became a factor that causes the pedestrians doesn’t utilize the pedestrian crossing facilities. Therefore, this research was structured to examine the relationship between the availability of the supporting elements of the pedestrian with pedestrian crossing facility usage based on user preferences. Data collection method used is primary survey consist of observation and the questionnaire. Sampling techniques used is purposive sampling with the number of respondents as many as 211 respondents by using questionnaire with ordinal scales to identify respondents’ consideration level of supporting elements pedestrian and crossing facility utilization factors. The survey is done on 15 crossing facilities area in 3 different locations with the same characteristics of land use in the form of higher education area (university area) and trades and services activities area. The analysis technique used is frequency distribution analysis in order to identify preference pedestrian on the availability of supporting elements of pedestrian and pedestrian crossing facility utilization factors, and chi square analysis is used to analyze the relationship between the availability of the supporting elements of the pedestrian with pedestrian crossing facility utilization. Based on the chi square analysis results with significance 5 % obtained the result that there are six supporting elements of pedestrian having correlation to the factors of pedestrian crossing facility utilization consist of the availability of sidewalk, pedestrian lights, Street Lighting Lamps, Pedestrian Crossing Markings Facilities, Sign Crossings Facilities, vegetation, and dustbin. So the result of this research can be considered for the government as main stakehoder especially the local government in preparing policy to provide supporting elements of pedestrian that should be on the area of pedestrian crossing facilities.

  3. 20 CFR 655.1116 - Element VI-What notification must facilities provide to registered nurses?

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... provide to registered nurses? 655.1116 Section 655.1116 Employees' Benefits EMPLOYMENT AND TRAINING... Requirements Must a Facility Meet to Employ H-1C Nonimmigrant Workers as Registered Nurses? § 655.1116 Element VI—What notification must facilities provide to registered nurses? (a) The sixth attestation element...

  4. 20 CFR 655.1116 - Element VI-What notification must facilities provide to registered nurses?

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... provide to registered nurses? 655.1116 Section 655.1116 Employees' Benefits EMPLOYMENT AND TRAINING... Requirements Must a Facility Meet to Employ H-1C Nonimmigrant Workers as Registered Nurses? § 655.1116 Element VI—What notification must facilities provide to registered nurses? (a) The sixth attestation element...

  5. Application of quality risk management to set viable environmental monitoring frequencies in biotechnology processing and support areas.

    PubMed

    Sandle, Tim

    2012-01-01

    Environmental monitoring programs are essential for pharmaceutical facilities in order to assess the level of environmental control. For biotechnology facilities there is little advice as to the frequency at which viable environmental monitoring should be conducted. This paper outlines an approach, based on the principles of quality risk management, for the development of a framework from which monitoring frequencies can be determined. This involved the identification of common hazards and the evaluation those hazards in terms of the severity of contamination and the probability of contamination occurring. These elements of risk were evaluated for different cleanrooms and the relative risks ranked. Once the risk scores were calculated, the methods for detecting risks within the cleanrooms were assessed. Risk filtering was then used to group different cleanrooms based on their relative risks and detection methods against predetermined monitoring frequencies. Through use of case study examples, the paper presents the model and describes how appropriate frequencies for the environmental monitoring of cleanrooms can be set. Cleanrooms in which biotechnology pharmaceutical processing takes place are subject to environmental monitoring. The frequency at which such monitoring should be performed can be difficult to determine. This paper uses quality risk assessment methods to construct a framework for determining monitoring frequencies and illustrates the suitability of the framework through a case study.

  6. Concentrations of trace elements and PCDD/Fs around a municipal solid waste incinerator in Girona (Catalonia, Spain). Human health risks for the population living in the neighborhood.

    PubMed

    Rovira, Joaquim; Nadal, Martí; Schuhmacher, Marta; Domingo, José L

    2018-07-15

    Previously to the modernization of the municipal solid waste incinerator (MSWI) of Campdorà (Girona, Catalonia, Spain) two sampling campaigns (2015 and 2016) were conducted. In each campaign, 8 soil and 4 air samples (PM 10 and total particle phase and gas phase) were collected. The levels of As, Cd, Co, Cr, Cu, Hg, Mn, Ni, Pb, Sb, Sn, Tl and V, and PCDD/Fs were analysed at different distances and wind directions around the MSWI. Environmental levels of trace elements and PCDD/Fs were used to assess exposure and health risks (carcinogenic and non-carcinogenic) for the population living around the facility. In soils, no significant differences were observed for trace elements and PCDD/Fs between both campaigns. In air, significant higher levels of As, Cd, Co, Mn, Ni, Pb, Tl and V were detected in 2016. Regarding soil levels, only Cd (distances) and As, Cu, Mn, and Ni (wind directions) showed significant differences. No differences were noted in the concentrations of trace elements and PCDD/Fs in air levels with respect to distances and directions to the MSWI. No differences were registered in air levels (elements and PCDD/Fs) between points influenced by MSWI emissions and background point. However some differences in congener profile were noted regarding from where back-trajectories come from (HYSPLIT model results), pointing some influence of Barcelona metropolitan area. The concentrations of trace elements and PCDD/Fs were similar -or even lower- than those reported around other MSWIs in Catalonia and various countries. Non-carcinogenic risks were below the safety limit (HQ<1). In turn, carcinogenic risks due to exposure to trace elements and PCDD/Fs were in acceptable ranges, according to national and international standard regulations. Copyright © 2018 Elsevier B.V. All rights reserved.

  7. Remedial Investigation/Feasibility Study (RI/FS) process, elements and techniques guidance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    This manual provides detailed guidance on Remedial Investigation/Feasibility Studies (RI/FSs) conducted pursuant to the Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) at Department of Energy (DOE) facilities. The purpose of the RI/FS, to assess the risk posed by a hazardous waste site and to determine the best way to reduce that risk, and its structure (site characterization, risk assessment, screening and detailed analysis of alternatives, etc.) is defined in the National Oil and Hazardous Substances Pollution Contingency Plan (NCP) and further explained in the Environmental Protection Agency`s (EPA`s) Guidance for Conducting Remedial Investigations and Feasibility Studies Under CERCLA (Interimmore » Final) 540/G-89/004, OSWER Directive 9355.3-01, October 1988. Though issued in 1988, the EPA guidance remains an excellent source of information on the conduct and structure of an RI/FS. This document makes use of supplemental RI/FS-related guidance that EPA has developed since its initial document was issued in 1988, incorporates practical lessons learned in more than 12 years of experience in CERCLA hazardous site remediation, and drawing on those lessons, introduces the Streamlined Approach For Environmental Restoration (SAFER), developed by DOE as a way to proceed quickly and efficiently through the RI/FS process at DOE facilities. Thus as its title implies, this guidance is intended to describe in detail the process and component elements of an RI/FS, as well as techniques to manage the RI/FS effectively.« less

  8. A Review of Events That Expose Children to Elemental Mercury in the United States

    PubMed Central

    Lee, Robin; Middleton, Dan; Caldwell, Kathleen; Dearwent, Steve; Jones, Steven; Lewis, Brian; Monteilh, Carolyn; Mortensen, Mary Ellen; Nickle, Richard; Orloff, Kenneth; Reger, Meghan; Risher, John; Rogers, Helen Schurz; Watters, Michelle

    2009-01-01

    Objective Concern for children exposed to elemental mercury prompted the Agency for Toxic Substances and Disease Registry and the Centers for Disease Control and Prevention to review the sources of elemental mercury exposures in children, describe the location and proportion of children affected, and make recommendations on how to prevent these exposures. In this review, we excluded mercury exposures from coal-burning facilities, dental amalgams, fish consumption, medical waste incinerators, or thimerosal-containing vaccines. Data sources We reviewed federal, state, and regional programs with information on mercury releases along with published reports of children exposed to elemental mercury in the United States. We selected all mercury-related events that were documented to expose (or potentially expose) children. We then explored event characteristics (i.e., the exposure source, location). Data synthesis Primary exposure locations were at home, at school, and at other locations such as industrial property not adequately remediated or medical facilities. Exposure to small spills from broken thermometers was the most common scenario; however, reports of such exposures are declining. Discussion and conclusions Childhood exposures to elemental mercury often result from inappropriate handling or cleanup of spilled mercury. The information reviewed suggests that most releases do not lead to demonstrable harm if the exposure period is short and the mercury is properly cleaned up. Recommendations Primary prevention should include health education and policy initiatives. For larger spills, better coordination among existing surveillance systems would assist in understanding the risk factors and in developing effective prevention efforts. PMID:19590676

  9. 20 CFR 655.1113 - Element III-What does “facility wage rate” mean?

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... Facility Meet to Employ H-1C Nonimmigrant Workers as Registered Nurses? § 655.1113 Element III—What does... for registered nurses similarly employed by the facility.” (b) The facility must pay the higher of the...., prevailing wage). (c) Wage obligations for H-1C nurses in nonproductive status—(1) Circumstances where wages...

  10. 20 CFR 655.1113 - Element III-What does “facility wage rate” mean?

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... Facility Meet to Employ H-1C Nonimmigrant Workers as Registered Nurses? § 655.1113 Element III—What does... for registered nurses similarly employed by the facility.” (b) The facility must pay the higher of the...., prevailing wage). (c) Wage obligations for H-1C nurses in nonproductive status—(1) Circumstances where wages...

  11. A New Large Vibration Test Facility Concept for the James Webb Space Telescope

    NASA Technical Reports Server (NTRS)

    Ross, Brian P.; Johnson, Eric L.; Hoksbergen, Joel; Lund, Doug

    2014-01-01

    The James Webb Space Telescope consists of three main components, the Integrated Science Instrument Module (ISIM) Element, the Optical Telescope Element (OTE), and the Spacecraft Element. The ISIM and OTE are being assembled at the National Aeronautics and Space Administration's Goddard Spaceflight Center (GSFC). The combined OTE and ISIM Elements, called OTIS, will undergo sine vibration testing before leaving Goddard. OTIS is the largest payload ever tested at Goddard and the existing GSFC vibration facilities are incapable of performing a sine vibration test of the OTIS payload. As a result, a new large vibration test facility is being designed. The new facility will consist of a vertical system with a guided head expander and a horizontal system with a hydrostatic slip table. The project is currently in the final design phase with installation to begin in early 2015 and the facility is expected to be operational by late 2015. This paper will describe the unique requirements for a new large vibration test facility and present the selected final design concepts.

  12. Tuberculosis in the workplace: OSHA's compliance experience.

    PubMed

    McDiarmid, M; Gamponia, M J; Ryan, M A; Hirshon, J M; Gillen, N A; Cox, M

    1996-03-01

    Inspections of 272 facilities were performed between May 1992 and October 1994 to determine compliance with applicable Occupational Safety and Health Administration (OSHA) requirements for prevention of tuberculosis (TB) transmission. Retrospective record review of two data sources: (1) OSHA's Computerized Integrated Management Information System and (2) an inspector-completed questionnaire on inspection results. Inspections of five types of facilities: healthcare institutions, correctional facilities, homeless shelters, long-term-care facilities for the elderly, and others, including drug treatment centers that the Centers for Disease Control and Prevention (CDC) identified as having a higher than expected rate of TB. The OSHA Compliance Memorandum, based on the 1990 CDC Guidelines, which outlined elements of a TB prevention program, was used in performing 272 inspections of facilities between May 1992 and October 1994. Elements of compliance were recorded and reviewed from the IMIS database and inspectors' questionnaires. Regulated facilities were not fully compliant with OSHA guidance. Generally, healthcare facilities performed better than other facilities. Most facilities (79%) were compliant with administrative elements of a comprehensive TB control program, such as early identification of known or suspected infectious TB patients and skin testing of workers. Only 29% of inspected facilities were found to have acceptable respiratory protection programs for the prevention of occupational TB. Facilities have not been fully compliant with the OSHA memorandum describing protection of workers from TB. Facility compliance was better with some traditionally recognized TB infection control elements, but was weaker in the area of respiratory protection programs. This may reflect a lack of familiarity with the latter type of hazard protection.

  13. Environmental risk assessment of cobalt and manganese from industrial sources in an estuarine system.

    PubMed

    Barrio-Parra, F; Elío, J; De Miguel, E; García-González, J E; Izquierdo, M; Álvarez, R

    2018-04-01

    A total of 74 samples of soil, sediment, industrial sludge, and surface water were collected in a Mediterranean estuarine system in order to assess the potential ecological impact of elevated concentrations of Co and Mn associated with a Terephthalic (PTA) and Isophthalic (PIPA) acids production plant. Samples were analyzed for elemental composition (37 elements), pH, redox potential, organic carbon, and CaCO 3 content, and a group of 16 selected samples were additionally subjected to a Tessier sequential extraction. Co and Mn soil concentrations were significantly higher inside the industrial facility and around its perimeter than in background samples, and maximum dissolved Co and Mn concentrations were found in a creek near the plant's discharge point, reaching values 17,700 and 156 times higher than their respective background concentrations. The ecological risk was evaluated as a function of Co and Mn fractionation and bioavailability which were controlled by the environmental conditions generated by the advance of seawater into the estuarine system during high tide. Co appeared to precipitate near the river mouth due to the pH increase produced by the influence of seawater intrusion, reaching hazardous concentrations in sediments. In terms of their bioavailability and the corresponding risk assessment code, both Co and Mn present sediment concentrations that result in medium to high ecological risk whereas water concentrations of both elements reach values that more than double their corresponding Secondary Acute Values.

  14. Proposal for a new categorization of aseptic processing facilities based on risk assessment scores.

    PubMed

    Katayama, Hirohito; Toda, Atsushi; Tokunaga, Yuji; Katoh, Shigeo

    2008-01-01

    Risk assessment of aseptic processing facilities was performed using two published risk assessment tools. Calculated risk scores were compared with experimental test results, including environmental monitoring and media fill run results, in three different types of facilities. The two risk assessment tools used gave a generally similar outcome. However, depending on the tool used, variations were observed in the relative scores between the facilities. For the facility yielding the lowest risk scores, the corresponding experimental test results showed no contamination, indicating that these ordinal testing methods are insufficient to evaluate this kind of facility. A conventional facility having acceptable aseptic processing lines gave relatively high risk scores. The facility showing a rather high risk score demonstrated the usefulness of conventional microbiological test methods. Considering the significant gaps observed in calculated risk scores and in the ordinal microbiological test results between advanced and conventional facilities, we propose a facility categorization based on risk assessment. The most important risk factor in aseptic processing is human intervention. When human intervention is eliminated from the process by advanced hardware design, the aseptic processing facility can be classified into a new risk category that is better suited for assuring sterility based on a new set of criteria rather than on currently used microbiological analysis. To fully benefit from advanced technologies, we propose three risk categories for these aseptic facilities.

  15. Nanominerals, fullerene aggregates, and hazardous elements in coal and coal combustion-generated aerosols: An environmental and toxicological assessment.

    PubMed

    Saikia, Jyotilima; Narzary, Bardwi; Roy, Sonali; Bordoloi, Manobjyoti; Saikia, Prasenjit; Saikia, Binoy K

    2016-12-01

    Studies on coal-derived nanoparticles as well as nano-minerals are important in the context of the human health and the environment. The coal combustion-generated aerosols also affect human health and environmental quality aspects in any coal-fired station. In this study, the feed coals and their combustion-generated aerosols from coal-fired boilers of two tea industry facilities were investigated for the presence of nanoparticles/nano minerals, fullerene aggregates, and potentially hazardous elements (PHEs). The samples were characterized by using X-ray diffraction (XRD), Time-of-flight secondary ion mass spectroscopy (TOF-SIMS), High resolution-transmission electron microscopy/energy dispersive spectroscopy (HR-TEM/EDS) and Ultra Violet-visible spectroscopy (UV-Vis) to know their extent of environmental risks to the human health when present in coals and aerosols. The feed coals contain mainly clay minerals, whilst glass fragments, spinel, quartz, and other minerals occur in lesser quantities. The PM samples contain potentially hazardous elements (PHEs) like As, Pb, Cd and Hg. Enrichment factor of the trace elements in particulate matters (PMs) was calculated to determine their sources. The aerosol samples were also found to contain nanomaterials and ultrafine particles. The fullerene aggregates along with potentially hazardous elements were also detected in the aerosol samples. The cytotoxicity studies on the coal combustion-generated PM samples show their potential risk to the human health. This detailed investigation on the inter-relationship between the feed coals and their aerosol chemistry will be useful for understanding the extent of environmental hazards and related human health risk. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. Space Radiation Program Element Tissue Sharing Initiative

    NASA Technical Reports Server (NTRS)

    Wu, H.; Huff, J. L.; Simonsen, L. C.

    2014-01-01

    Over the years, a large number of animal experiments have been conducted at the NASA Space Radiation Laboratory and other facilities under the support of the NASA Space Radiation Program Element (SRPE). Studies using rodents and other animal species to address the space radiation risks will remain a significant portion of the research portfolio of the Element. In order to maximize scientific return of the animal studies, SRPE is taking the initiative to promote tissue sharing among the scientists in the space radiation research community. This initiative is enthusiastically supported by the community members as voiced in the responses to a recent survey. For retrospective tissue samples, an online platform will be established for the PIs to post a list of the available samples, and to exchange information with the potential recipients. For future animal experiments, a tissue sharing policy is being developed by SRPE.

  17. Walkthrough screening evaluation field guide. Natural phenomena hazards at Department of Energy facilities: Revision 2

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eder, S.J.; Eli, M.W.; Salmon, M.W.

    1993-11-01

    The US Department of Energy (DOE) has a large inventory of existing facilities. Many of these facilities were not designed and constructed to current natural phenomena hazard (NPH) criteria. The NPH events include earthquakes, extreme winds and tornadoes, and floods. DOE Order 5480.28 establishes policy and requirements for NPH mitigation for DOE facilities. DOE is conducting a multiyear project to develop evaluation guidelines for assessing the condition and determining the need for upgrades at DOE facilities. One element of the NPH evaluation guidelines` development involves the existing systems and components at DOE facilities. This effort is described in detail inmore » a cited reference. In the interim period prior to availability of the final guidelines, DOE facilities are encouraged to implement an NPH walk through screening evaluation process by which systems and components that need attention can be rapidly identified. Guidelines for conducting the walk through screening evaluations are contained herein. The result of the NPH walk through screening evaluation should be a prioritized list of systems and components that need further action. Simple and inexpensive fixes for items identified in the walk through as marginal or inadequate should be implemented without further study. By implementing an NPH walk through screening evaluation, DOE facilities may realize significant reduction in risk from NPH in the short term.« less

  18. Elemental quantification, chemistry, and source apportionment in golf course facilities in a semi-arid urban landscape using a portable X-ray fluorescence spectrometer

    NASA Astrophysics Data System (ADS)

    Udeigwe, T. K.; Young, J.; Kandakji, T.; Weindorf, D. C.; Mahmoud, M. A.; Stietiya, M. H.

    2015-04-01

    This study extends the application of the portable X-ray fluorescence (PXRF) spectrometry to the examination of elements in semi-arid urban landscapes of the Southern High Plains (SHP) of the United States, focusing on golf courses. The complex environmental challenges of this region and the unique management practices at golf course facilities could lead to differences in concentration and in the chemistry of elements between managed (irrigated) and non-managed (non-irrigated) portions of these facilities. Soil samples were collected at depths of 0-10, 10-20, and 20-30 cm from managed and non-managed areas of seven different facilities in the city of Lubbock, Texas, and analyzed for a suite of soil properties. Total elemental quantification was conducted using a PXRF spectrometer. Findings mostly indicated no significant differences in the concentration of examined elements between the managed and non-managed areas of the facilities. However, strong positive relationships (R = 0.82-0.91, p < 0.001) were observed among elements (e.g., Fe on the one hand and Cr, Mn, Ni, and As on the other; Cu and Zn; As and Cr) and between these elements and soil constituents or properties such as clay, calcium carbonate, organic matter, and pH. The strengths of these relationships were mostly higher in the non-managed areas, suggesting a possible alteration in the chemistry of these elements by anthropogenic influences in the managed areas. Principal component and correlation analyses within the managed areas suggested that As, Cr, Fe, Mn, and Ni could be of lithogenic origin, while Cu, Pb, and Zn could have anthropogenic influences. Only one possible, likely lithogenic, source of the elements was identified within the non-managed areas. As evidenced by the study, the PXRF spectrometer can be a valuable tool for elemental quantification and rapid investigation of elemental interaction and source apportionment in semi-arid climates.

  19. Elemental quantification, chemistry, and source apportionment in golf course facilities in semi-arid urban landscape using portable x-ray fluorescence spectrometer

    NASA Astrophysics Data System (ADS)

    Udeigwe, T. K.; Young, J.; Kandakji, T.; Weindorf, D. C.; Mahmoud, M. A.; Stietiya, M. H.

    2015-01-01

    This study extends the application of the portable x-ray fluorescence (PXRF) spectrometry to examination of elements in semi-arid urban landscapes of the Southern High Plains (SHP) of the United States (US), focusing on golf courses. The complex environmental challenges of this region and the unique management practices at golf course facilities could lead to differences in concentration and chemistry of elements between managed (irrigated) and non-managed (non-irrigated) portions of these facilities. Soil samples were collected at the depths of 0-10, 10-20, and 20-30 cm from managed and non-managed areas of seven different facilities in the city of Lubbock, Texas, and analyzed for a suite of soil properties. Total elemental quantification was conducted using PXRF. Findings mostly indicated no significant differences in concentration of examined elements between the managed and non-managed areas of the facilities. However, strong positive relationships (R2 = 0.82-0.91, p < 0.001) were observed among elements (e.g. Fe and each of Cr, Mn, Ni, and As; Cu and Zn; As and Cr) and between these elements and soil constituents or properties such as clay, calcium carbonate, organic matter, and pH. The strengths of these relationships were mostly higher in the non-managed areas, suggesting possible alteration in the chemistry of these elements by anthropogenic influences. Principal component analyses (PCA) and correlation analyses within the managed areas suggested that As, Cr, Fe, Mn, and Ni could be of lithogenic origin, while Cu, Pb, and Zn were attributed to anthropogenic influences. Only one possible source of element, likely lithogenic, was identified within non-managed areas. As evidenced from the study, the PXRF can be a valuable tool for elemental quantification, and rapid investigation of elemental interaction and source apportionment in semi-arid climates.

  20. Lunar base launch and landing facilities conceptual design

    NASA Technical Reports Server (NTRS)

    Phillips, Paul G.; Simonds, Charles H.; Stump, William R.

    1992-01-01

    The purpose of this study was to perform a first look at the requirements for launch and landing facilities for early lunar bases and to prepared conceptual designs for some of these facilities. The emphasis of the study is on the facilities needed from the first manned landing until permanent occupancy, the Phase 2 lunar base. Factors including surface characteristics, navigation system, engine blast effects, and expected surface operations are used to develop landing pad designs, and definitions fo various other elements of the launch and landing facilities. Finally, the dependence of the use of these elements and the evolution of the facilities are established.

  1. Requirements for Simulating Space Radiation With Particle Accelerators

    NASA Technical Reports Server (NTRS)

    Schimmerling, W.; Wilson, J. W.; Cucinotta, F.; Kim, M-H Y.

    2004-01-01

    Interplanetary space radiation consists of fully ionized nuclei of atomic elements with high energy for which only the few lowest energy ions can be stopped in shielding materials. The health risk from exposure to these ions and their secondary radiations generated in the materials of spacecraft and planetary surface enclosures is a major limiting factor in the management of space radiation risk. Accurate risk prediction depends on a knowledge of basic radiobiological mechanisms and how they are modified in the living tissues of a whole organism. To a large extent, this knowledge is not currently available. It is best developed at ground-based laboratories, using particle accelerator beams to simulate the components of space radiation. Different particles, in different energy regions, are required to study different biological effects, including beams of argon and iron nuclei in the energy range 600 to several thousand MeV/nucleon and carbon beams in the energy range of approximately 100 MeV/nucleon to approximately 1000 MeV/nucleon. Three facilities, one each in the United States, in Germany and in Japan, currently have the partial capability to satisfy these constraints. A facility has been proposed using the Brookhaven National Laboratory Booster Synchrotron in the United States; in conjunction with other on-site accelerators, it will be able to provide the full range of heavy ion beams and energies required. International cooperation in the use of these facilities is essential to the development of a safe international space program.

  2. Concentrations of Radionuclides and Trace Elements in Environmantal Media arond te Dual-Axis Radiographic Hydrodynamic Test Facilit at Los Alamos National Laboratory during 2005

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    G.J.Gonzales; P.R. Fresquez; C.D.Hathcock

    2006-05-15

    The Mitigation Action Plan (MAP) for the Dual-Axis Radiographic Hydrodynamic Test (DARHT) facility at Los Alamos National Laboratory requires that samples of biotic and abiotic media be collected after operations began to determine if there are any human health or environmental impacts. The DARHT facility is the Laboratory's principal explosive test facility. To this end, samples of soil and sediment, vegetation, bees, and birds were collected around the facility in 2005 and analyzed for concentrations of {sup 3}H, {sup 137}Cs, {sup 90}Sr, {sup 238}Pu, {sup 239,240}Pu, {sup 241}Am, {sup 234}U, {sup 235}U, {sup 238}U, Ag, As, Ba, Be, Cd, Cr,more » Cu, Hg, Ni, Pb, Sb, Se, and Tl. Bird populations have also been monitored. Contaminant results, which represent up to six sample years since the start of operations, were compared with (1) baseline statistical reference levels (BSRLs) established over a four-year preoperational period before DARHT facility operations, (2) screening levels (SLs), and (3) regulatory standards. Most radionuclides and trace elements were below BSRLs and those few samples that contained radionuclides and trace elements above BSRLs were below SLs. Concentrations of radionuclides and nonradionuclides in biotic and abiotic media around the DARHT facility do not pose a significant human health hazard. The total number of birds captured and number of species represented were similar in 2003 and 2004, but both of these parameters increased substantially in 2005. Periodic interruption of the scope and schedule identified in the MAP generally should have no impact on meeting the intent of the MAP. The risk of not sampling one of the five media in any given year is that if a significant impact to contaminant levels were to occur there would exist a less complete understanding of the extent of the change to the baseline for these media and to the ecosystem as a whole. Since the MAP is a requirement that was established under the regulatory framework of the National Environmental Policy Act, any changes to the monitoring requirements in the MAP must be negotiated with and ultimately approved by the U.S. Department of Energy.« less

  3. 47 CFR 69.124 - Interconnection charge.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) COMMON CARRIER SERVICES (CONTINUED) ACCESS CHARGES..., facilities-based rate elements in the future, from the part 69 transport revenue requirement, and dividing by... local exchange carrier anticipates will be reassigned to other, facilities-based rate elements in the...

  4. Fine particulate matter (PM2.5) in a compost facility: heavy metal contaminations and health risk assessment, Tehran, Iran.

    PubMed

    Kermani, Majid; Farzadkia, Mahdi; Kalantari, Roshanak Rezaei; Bahmani, Zohreh

    2018-06-01

    The aim of this study was to evaluate the concentration of PM 2.5 particles, potential sources, and determination of health risk assessment of heavy metals in various parts of composting facilities of Tehran's Kahrizak. A total of 60 PM 2.5 particle samples were collected every 3 days from January to March 2016. To analyze the heavy metals, inductively coupled plasma atomic emission spectroscopy (ICP-AES) was applied. SEM-EDX analysis indicated that metals of Al, Si, Mg, Na, Au, S, Ca, K, and Co were dominant in the structure of particles. The concentration of PM 2.5 was found to be the highest in the final processing site (c), followed by primary processing site (a) and the aerated site (b). The mean concentrations of Al and Fe in all sampling sites of a, b, and c were 7.46 ± 2.73, 1.48 ± 0.59, 24.30 ± 8.23 μg/m 3 and 4.97 ± 2.83, 1.33 ± 0.48, 16.48 ± 7.36, respectively. The enrichment factor order of the trace elements was as follows: Cd > As > Pb > Zn > Cu > V > Cr > Ni > Mn > Fe > Al, with the highest EF value exceeding 10,000 for Cd at the a site. For all sampling sites in composting facilities, the cancer risk was more than > 1 × 10 -4 as posed by the total of five carcinogenic metals (Pb, Cr, As, Ni, and Cd), indicating that risk factors were not negligible.

  5. 20 CFR 655.1118 - Element VIII-What are the limitations as to where the H-1C nonimmigrant may be employed?

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... STATES What Requirements Must a Facility Meet to Employ H-1C Nonimmigrant Workers as Registered Nurses... eighth attestation element requires that the facility attest that it will not authorize any H-1C nurse to perform services at any worksite not controlled by the facility or transfer any H-1C nurse from one...

  6. 20 CFR 655.1118 - Element VIII-What are the limitations as to where the H-1C nonimmigrant may be employed?

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... STATES What Requirements Must a Facility Meet to Employ H-1C Nonimmigrant Workers as Registered Nurses... eighth attestation element requires that the facility attest that it will not authorize any H-1C nurse to perform services at any worksite not controlled by the facility or transfer any H-1C nurse from one...

  7. The Prompt Gamma Neutron Activation Analysis Facility at ICN—Pitesti

    NASA Astrophysics Data System (ADS)

    Bǎrbos, D.; Pǎunoiu, C.; Mladin, M.; Cosma, C.

    2008-08-01

    PGNAA is a very widely applicable technique for determining the presence and amount of many elements simultaneously in samples ranging in size from micrograms to many grams. PGNAA is characterized by its capability for nondestructive multi-elemental analysis and its ability to analyse elements that cannot be determined by INAA. By means of this PGNAA method we are able to increase the performace of INAA method. A facility has been developed at Institute for Nuclear Research—Piteşti so that the unique features of prompt gamma-ray neutron activation analysis can be used to measure trace and major elements in samples. The facility is linked at the radial neutron beam tube at ACPR-TRIGA reactor. During the PGNAA—facility is in use the ACPR reactor will be operated in steady-state mode at 250 KW maximum power. The facility consists of a radial beam-port, external sample position with shielding, and induced prompt gamma-ray counting system. Thermal neutron flux with energy lower than cadmium cut-off at the sample position was measured using thin gold foil is: φscd = 1.106 n/cm2/s with a cadmium ratio of:80. The gamma-ray detection system consist of an HpGe detector of 16% efficiency (detector model GC1518) with 1.85 keV resolution capability. The HpGe is mounted with its axis at 90° with respect to the incident neutron beam at distance about 200mm from the sample position. To establish the performance capabilities of the facility, irradiation of pure element or sample compound standards were performed to identify the gama-ray energies from each element and their count rates.

  8. Elemental mercury contamination survey in a chlor-alkali plant by the use of transplanted Spanish moss, Tillandsia usneoides (L.).

    PubMed

    Calasans, C F; Malm, O

    1997-12-22

    Atmospheric Hg0 contamination and the potential risk of occupational exposure were evaluated in a chlor-alkali facility by the use of transplanted Tillandsia usneoides. This plant species was selected since it presents some features that makes it useful for air monitoring purposes. After short-term exposure (15 days), control plants showed a mean concentration of 0.2 microgram Hg.g-1 whereas Hg values in transplants ranged from 1 to 10,400 micrograms.g-1. This latter value was observed near an elemental Hg spillage. Even after exposure to toxic conditions plant metabolism was still operative, allowing the transplant technique to be employed to assess both Hg taken up through the stomata and Hg associated with particles deposited on the biomonitor.

  9. Numerical aerodynamic simulation facility preliminary study, volume 1

    NASA Technical Reports Server (NTRS)

    1977-01-01

    A technology forecast was established for the 1980-1985 time frame and the appropriateness of various logic and memory technologies for the design of the numerical aerodynamic simulation facility was assessed. Flow models and their characteristics were analyzed and matched against candidate processor architecture. Metrics were established for the total facility, and housing and support requirements of the facility were identified. An overview of the system is presented, with emphasis on the hardware of the Navier-Stokes solver, which is the key element of the system. Software elements of the system are also discussed.

  10. Ground test facility for SEI nuclear rocket engines

    NASA Astrophysics Data System (ADS)

    Harmon, Charles D.; Ottinger, Cathy A.; Sanchez, Lawrence C.; Shipers, Larry R.

    1992-07-01

    Nuclear (fission) thermal propulsion has been identified as a critical technology for a manned mission to Mars by the year 2019. Facilities are required that will support ground tests to qualify the nuclear rocket engine design, which must support a realistic thermal and neutronic environment in which the fuel elements will operate at a fraction of the power for a flight weight reactor/engine. This paper describes the design of a fuel element ground test facility, with a strong emphasis on safety and economy. The details of major structures and support systems of the facility are discussed, and a design diagram of the test facility structures is presented.

  11. Senator Doug Jones (D-AL) Tour of MSFC Facilities

    NASA Image and Video Library

    2018-02-22

    Senator Doug Jones (D-AL.) and wife, Louise, tour Marshall Space Flight facilities. Steve Doering, manager, Stages Element, Space Launch System (SLS) program at MSFC, views the test stand 4693 where key SLS structural elements will be subjected to stress testing simulating space flight.

  12. Heavy metals in industrially emitted particulate matter in Ile-Ife, Nigeria.

    PubMed

    Ogundele, Lasun T; Owoade, Oyediran K; Hopke, Philip K; Olise, Felix S

    2017-07-01

    Iron and steel smelting facilities generate large quantities of airborne particulate matter (PM) through their various activities and production processes. The resulting PM that contains a variety of heavy metals has potentially detrimental impacts on human health and the environment. This study was conducted to assess the potential health effects of the pollution from the heavy metals in the airborne PM sampled in the vicinity of secondary smelting operations in Ile-Ife, Nigeria. X-ray fluorescence (XRF) was used to determine the elemental concentration of Pb, Cr, Cd, Zn, Mn, As, Fe, Cu, and Ni in the size-segregated PM samples. Pollution Indices (PI) consisting of Contamination Factor (CF), Degree of Contamination (DC) and Pollution Index Load (PLI) and Target Hazard Quotient (THQ) were employed to assess the pollution risk associated with the heavy metals in the PM. CF, DC and PLI values were 3< CF <6, >32 and >1, respectively for the three sites, indicating deterioration of the ambient air quality in the vicinity of the smelter. The heavy metals in the airborne PM pose a severe health risk to people living in vicinity of the facility and to its workers. The diminished air quality with the associated health risks directly depends on the industrial emissions from steel production and control measures are recommended to mitigate the likely risks. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Automated rendezvous and capture development infrastructure

    NASA Technical Reports Server (NTRS)

    Bryan, Thomas C.; Roe, Fred; Coker, Cynthia

    1992-01-01

    The facilities at Marshall Space Flight Center and JSC to be utilized to develop and test an autonomous rendezvous and capture (ARC) system are described. This includes equipment and personnel facility capabilities to devise, develop, qualify, and integrate ARC elements and subsystems into flight programs. Attention is given to the use of a LEO test facility, the current concept and unique system elements of the ARC, and the options available to develop ARC technology.

  14. New Concepts and Fermilab Facilities for Antimatter Research

    NASA Astrophysics Data System (ADS)

    Jackson, Gerald

    2008-04-01

    There has long been significant interest in continuing antimatter research at the Fermi National Accelerator Laboratory. Beam kinetic energies ranging from 10 GeV all the way down to the eV scale and below are of interest. There are three physics missions currently being developed: the continuation of charmonium physics utilizing an internal target; atomic physics with in-flight generated antihydrogen atoms; and deceleration to thermal energies and paasage of antiprotons through a grating system to determine their gravitation acceleration. Non-physics missions include the study of medical applications, tests of deep-space propulsion concepts, low-risk testing of nuclear fuel elements, and active interrogation for smuggled nuclear materials in support of homeland security. This paper reviews recent beam physics and accelerator technology innovations in the development of methods and new Fermilab facilities for the above missions.

  15. Data Element Dictionary: Facilities. Second Edition.

    ERIC Educational Resources Information Center

    Martin, James S.

    This document is intended to serve as a guide for institutions in the development of data bases to support the implementation of planning and management systems. This publication serves to identify and describe those facilities-related data elements: (1) required to support current National Center for Higher Education Management Systems (NCHEMS)…

  16. Studies in a transonic rotor aerodynamics and noise facility

    NASA Technical Reports Server (NTRS)

    Wright, S. E.; Lee, D. J.; Crosby, W.

    1984-01-01

    The design, construction and testing of a transonic rotor aerodynamics and noise facility was undertaken, using a rotating arm blade element support technique. This approach provides a research capability intermediate between that of a stationary element in a moving flow and that of a complete rotating blade system, and permits the acoustic properties of blade tip elements to be studied in isolation. This approach is an inexpensive means of obtaining data at high subsonic and transonic tip speeds on the effect of variations in tip geometry. The facility may be suitable for research on broad band noise and discrete noise in addition to high-speed noise. Initial tests were conducted over the Mach number range 0.3 to 0.93 and confirmed the adequacy of the acoustic treatment used in the facility to avoid reflection from the enclosure.

  17. Systematic risk assessment methodology for critical infrastructure elements - Oil and Gas subsectors

    NASA Astrophysics Data System (ADS)

    Gheorghiu, A.-D.; Ozunu, A.

    2012-04-01

    The concern for the protection of critical infrastructure has been rapidly growing in the last few years in Europe. The level of knowledge and preparedness in this field is beginning to develop in a lawfully organized manner, for the identification and designation of critical infrastructure elements of national and European interest. Oil and gas production, refining, treatment, storage and transmission by pipelines facilities, are considered European critical infrastructure sectors, as per Annex I of the Council Directive 2008/114/EC of 8 December 2008 on the identification and designation of European critical infrastructures and the assessment of the need to improve their protection. Besides identifying European and national critical infrastructure elements, member states also need to perform a risk analysis for these infrastructure items, as stated in Annex II of the above mentioned Directive. In the field of risk assessment, there are a series of acknowledged and successfully used methods in the world, but not all hazard identification and assessment methods and techniques are suitable for a given site, situation, or type of hazard. As Theoharidou, M. et al. noted (Theoharidou, M., P. Kotzanikolaou, and D. Gritzalis 2009. Risk-Based Criticality Analysis. In Critical Infrastructure Protection III. Proceedings. Third Annual IFIP WG 11.10 International Conference on Critical Infrastructure Protection. Hanover, New Hampshire, USA, March 23-25, 2009: revised selected papers, edited by C. Palmer and S. Shenoi, 35-49. Berlin: Springer.), despite the wealth of knowledge already created, there is a need for simple, feasible, and standardized criticality analyses. The proposed systematic risk assessment methodology includes three basic steps: the first step (preliminary analysis) includes the identification of hazards (including possible natural hazards) for each installation/section within a given site, followed by a criterial analysis and then a detailed analysis step. The criterial evaluation is used as a ranking system in order to establish the priorities for the detailed risk assessment. This criterial analysis stage is necessary because the total number of installations and sections on a site can be quite large. As not all installations and sections on a site contribute significantly to the risk of a major accident occurring, it is not efficient to include all installations and sections in the detailed risk assessment, which can be time and resource consuming. The selected installations are then taken into consideration in the detailed risk assessment, which is the third step of the systematic risk assessment methodology. Following this step, conclusions can be drawn related to the overall risk characteristics of the site. The proposed methodology can as such be successfully applied to the assessment of risk related to critical infrastructure elements falling under the energy sector of Critical Infrastructure, mainly the sub-sectors oil and gas. Key words: Systematic risk assessment, criterial analysis, energy sector critical infrastructure elements

  18. Space Radiation Program Element Tissue Sharing Forum

    NASA Technical Reports Server (NTRS)

    Wu, H.; Mayeaux, B M.; Huff, J. L.; Simonsen, L. C.

    2016-01-01

    Over the years, a large number of animal experiments have been conducted at the NASA Space Radiation Laboratory and other facilities under the support of the NASA Space Radiation Program Element (SRPE). Studies using rodents and other animal species to address the space radiation risks will remain a significant portion of the research portfolio of the Element. In order to maximize scientific return of the animal studies, the SRPE has recently released the Space Radiation Tissue Sharing Forum. The Forum provides access to an inventory of investigator-stored tissue samples and enables both NASA SRPE members and NASA-funded investigators to exchange information regarding stored and future radiobiological tissues available for sharing. Registered users may review online data of available tissues, inquire about tissues posted, or request tissues for an upcoming study using an online form. Investigators who have upcoming sacrifices are also encouraged to post the availability of samples using the discussion forum. A brief demo of the forum will be given during the presentation

  19. Suited Occupant Injury Potential During Dynamic Spacecraft Flight Phases

    NASA Technical Reports Server (NTRS)

    Dub, Mark O.; McFarland, Shane M.

    2010-01-01

    In support of the Constellation Space Suit Element [CSSE], a new space-suit architecture will be created for support of Launch, Entry, Abort, Microgravity Extra- Vehicular Activity [EVA], and post-landing crew operations, safety and, under emergency conditions, survival. The space suit is unique in comparison to previous launch, entry, and abort [LEA] suit architectures in that it utilizes rigid mobility elements in the scye (i.e., shoulder) and the upper arm regions. The suit architecture also utilizes rigid thigh disconnect elements to create a quick disconnect approximately located above the knee. This feature allows commonality of the lower portion of the suit (from the thigh disconnect down), making the lower legs common across two suit configurations. This suit must interface with the Orion vehicle seat subsystem, which includes seat components, lateral supports, and restraints. Due to the unique configuration of spacesuit mobility elements, combined with the need to provide occupant protection during dynamic vehicle events, risks have been identified with potential injury due to the suit characteristics described above. To address the risk concerns, a test series has been developed in coordination with the Injury Biomechanics Research Laboratory [IBRL] to evaluate the likelihood and consequences of these potential issues. Testing includes use of Anthropomorphic Test Devices [ATDs; vernacularly referred to as "crash test dummies"], Post Mortem Human Subjects [PMHS], and representative seat/suit hardware in combination with high linear acceleration events. The ensuing treatment focuses on test purpose and objectives; test hardware, facility, and setup; and preliminary results.

  20. Nutritional strategies to boost immunity and prevent infection in elderly individuals.

    PubMed

    High, K P

    2001-12-01

    Older adults are at risk for malnutrition, which may contribute to their increased risk of infection. Nutritional supplementation strategies can reduce this risk and reverse some of the immune dysfunction associated with advanced age. This review discusses nutritional interventions that have been examined in clinical trials of older adults. The data support use of a daily multivitamin or trace-mineral supplement that includes zinc (elemental zinc, >20 mg/day) and selenium (100 microg/day), with additional vitamin E, to achieve a daily dosage of 200 mg/day. Specific syndromes may also be addressed by nutritional interventions (for example, cranberry juice consumption to reduce urinary tract infections) and may reduce antibiotic use in older adults, particularly those living in long-term care facilities. Drug-nutrient interactions are common in elderly individuals, and care providers should be aware of these interactions. Future research should evaluate important clinical end points rather than merely surrogate markers of immunity.

  1. 137Cs Radiological risk estimation of NSD facility at Karawang site by using RESRAD onsite application: effect of cover thickness

    NASA Astrophysics Data System (ADS)

    Setiawan, B.; Prihastuti, S.; Moersidik, S. S.

    2018-02-01

    The operational of near surface disposal facility during waste packages loading activity into the facility, or in a monitoring activity around disposal facility at Karawang area is predicted to give a radiological risk to radiation workers. The thickness of disposal facility cover system affected the number of radiological risk of workers. Due to this reason, a radiological risk estimation needs to be considered. RESRAD onsite code is applied for this purpose by analyse the individual accepted dose and radiological risk data of radiation workers. The obtained results and then are compared with radiation protection reference in accordance with national regulation. In this case, the data from the experimental result of Karawang clay as host of disposal facility such as Kd value of 137Cs was used. Results showed that the thickness of the cover layer of disposal facility affected to the radiological risk which accepted by workers in a near surface disposal facility.

  2. Spent nuclear fuel assembly inspection using neutron computed tomography

    NASA Astrophysics Data System (ADS)

    Pope, Chad Lee

    The research presented here focuses on spent nuclear fuel assembly inspection using neutron computed tomography. Experimental measurements involving neutron beam transmission through a spent nuclear fuel assembly serve as benchmark measurements for an MCNP simulation model. Comparison of measured results to simulation results shows good agreement. Generation of tomography images from MCNP tally results was accomplished using adapted versions of built in MATLAB algorithms. Multiple fuel assembly models were examined to provide a broad set of conclusions. Tomography images revealing assembly geometric information including the fuel element lattice structure and missing elements can be obtained using high energy neutrons. A projection difference technique was developed which reveals the substitution of unirradiated fuel elements for irradiated fuel elements, using high energy neutrons. More subtle material differences such as altering the burnup of individual elements can be identified with lower energy neutrons provided the scattered neutron contribution to the image is limited. The research results show that neutron computed tomography can be used to inspect spent nuclear fuel assemblies for the purpose of identifying anomalies such as missing elements or substituted elements. The ability to identify anomalies in spent fuel assemblies can be used to deter diversion of material by increasing the risk of early detection as well as improve reprocessing facility operations by confirming the spent fuel configuration is as expected or allowing segregation if anomalies are detected.

  3. Organizational- and individual-level correlates of posttreatment substance use: a multilevel analysis.

    PubMed

    Ghose, Toorjo

    2008-03-01

    In addressing the need to study the effects of organizational factors on individual-level treatment outcomes, this study used hierarchical models to examine the organizational- and individual-level correlates of posttreatment substance use. Risk for posttreatment use varied significantly across organizations. Factors in the external institutional environment of facilities significantly influenced risk for use: managed care regulation increased the risk, whereas Joint Commission on the Accreditation of Healthcare Organizations accreditation decreased it (p < .01 for both). On the individual level, longer treatment episodes and treatment completion reduced the risk (p < .01 for both) after controlling for client characteristics. The benefits of length of stay in treatment were modified by elements of the external institutional environment and organizational treatment technology. The ameliorative effects of prolonged treatment were reduced by higher levels of managed care regulation, organizational monitoring, caseload size (p < .01 for all), and proportion of degreed staff (p < .05). The results highlight the influence of organizational factors on posttreatment use.

  4. 40 CFR 61.121 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Elemental Phosphorus Plants § 61.121 Definitions. (a) Elemental phosphorus plant or plant means any facility that processes phosphate rock to produce elemental phosphorus. A plant includes all buildings...

  5. 40 CFR 61.121 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Elemental Phosphorus Plants § 61.121 Definitions. (a) Elemental phosphorus plant or plant means any facility that processes phosphate rock to produce elemental phosphorus. A plant includes all buildings...

  6. Nuclear Thermal Rocket Element Environmental Simulator (NTREES) Upgrade Activities

    NASA Technical Reports Server (NTRS)

    Emrich, William J. Jr.; Moran, Robert P.; Pearson, J. Boise

    2012-01-01

    To support the on-going nuclear thermal propulsion effort, a state-of-the-art non nuclear experimental test setup has been constructed to evaluate the performance characteristics of candidate fuel element materials and geometries in representative environments. The facility to perform this testing is referred to as the Nuclear Thermal Rocket Element Environment Simulator (NTREES). This device can simulate the environmental conditions (minus the radiation) to which nuclear rocket fuel components will be subjected during reactor operation. Test articles mounted in the simulator are inductively heated in such a manner so as to accurately reproduce the temperatures and heat fluxes which would normally occur as a result of nuclear fission and would be exposed to flowing hydrogen. Initial testing of a somewhat prototypical fuel element has been successfully performed in NTREES and the facility has now been shutdown to allow for an extensive reconfiguration of the facility which will result in a significant upgrade in its capabilities

  7. How to develop a Standard Operating Procedure for sorting unfixed cells

    PubMed Central

    Schmid, Ingrid

    2012-01-01

    Written Standard Operating Procedures (SOPs) are an important tool to assure that recurring tasks in a laboratory are performed in a consistent manner. When the procedure covered in the SOP involves a high-risk activity such as sorting unfixed cells using a jet-in-air sorter, safety elements are critical components of the document. The details on sort sample handling, sorter set-up, validation, operation, troubleshooting, and maintenance, personal protective equipment (PPE), and operator training, outlined in the SOP are to be based on careful risk assessment of the procedure. This review provides background information on the hazards associated with sorting of unfixed cells and the process used to arrive at the appropriate combination of facility design, instrument placement, safety equipment, and practices to be followed. PMID:22381383

  8. Groundwater contamination from waste management sites: The interaction between risk-based engineering design and regulatory policy: 1. Methodology

    NASA Astrophysics Data System (ADS)

    Massmann, Joel; Freeze, R. Allan

    1987-02-01

    This paper puts in place a risk-cost-benefit analysis for waste management facilities that explicitly recognizes the adversarial relationship that exists in a regulated market economy between the owner/operator of a waste management facility and the government regulatory agency under whose terms the facility must be licensed. The risk-cost-benefit analysis is set up from the perspective of the owner/operator. It can be used directly by the owner/operator to assess alternative design strategies. It can also be used by the regulatory agency to assess alternative regulatory policy, but only in an indirect manner, by examining the response of an owner/operator to the stimuli of various policies. The objective function is couched in terms of a discounted stream of benefits, costs, and risks over an engineering time horizon. Benefits are in the form of revenues for services provided; costs are those of construction and operation of the facility. Risk is defined as the cost associated with the probability of failure, with failure defined as the occurrence of a groundwater contamination event that violates the licensing requirements established for the facility. Failure requires a breach of the containment structure and contaminant migration through the hydrogeological environment to a compliance surface. The probability of failure can be estimated on the basis of reliability theory for the breach of containment and with a Monte-Carlo finite-element simulation for the advective contaminant transport. In the hydrogeological environment the hydraulic conductivity values are defined stochastically. The probability of failure is reduced by the presence of a monitoring network operated by the owner/operator and located between the source and the regulatory compliance surface. The level of reduction in the probability of failure depends on the probability of detection of the monitoring network, which can be calculated from the stochastic contaminant transport simulations. While the framework is quite general, the development in this paper is specifically suited for a landfill in which the primary design feature is one or more synthetic liners in parallel. Contamination is brought about by the release of a single, inorganic nonradioactive species into a saturated, high-permeability, advective, steady state horizontal flow system which can be analyzed with a two-dimensional analysis. It is possible to carry out sensitivity analyses for a wide variety of influences on this system, including landfill size, liner design, hydrogeological parameters, amount of exploration, extent of monitoring network, nature of remedial schemes, economic factors, and regulatory policy.

  9. Risk management study for the retired Hanford Site facilities: Qualitative risk evaluation for the retired Hanford Site facilities. Volume 3

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Coles, G.A.; Shultz, M.V.; Taylor, W.E.

    1993-09-01

    This document provides a risk evaluation of the 100 and 200 Area retired, surplus facilities on the Hanford Site. Also included are the related data that were compiled by the risk evaluation team during investigations performed on the facilities. Results are the product of a major effort performed in fiscal year 1993 to produce qualitative information that characterizes certain risks associated with these facilities. The retired facilities investigated for this evaluation are located in the 100 and 200 Areas of the 1,450-km{sup 2} (570-mi{sup 2}) Hanford Site. The Hanford Site is a semiarid tract of land in southeastern Washington State.more » The nearest population center is Richland, Washington, (population 32,000) 30-km (20 mi) southeast of the 200 Area. During walkdown investigations of these facilities, data on real and potential hazards that threatened human health or safety or created potential environmental release issues were identified by the risk evaluation team. Using these findings, the team categorized the identified hazards by facility and evaluated the risk associated with each hazard. The factors contributing to each risk, and the consequence and likelihood of harm associated with each hazard also are included in this evaluation.« less

  10. Site-wide seismic risk model for Savannah River Site nuclear facilities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eide, S.A.; Shay, R.S.; Durant, W.S.

    1993-09-01

    The 200,000 acre Savannah River Site (SRS) has nearly 30 nuclear facilities spread throughout the site. The safety of each facility has been established in facility-specific safety analysis reports (SARs). Each SAR contains an analysis of risk from seismic events to both on-site workers and the off-site population. Both radiological and chemical releases are considered, and air and water pathways are modeled. Risks to the general public are generally characterized by evaluating exposure to the maximally exposed individual located at the SRS boundary and to the off-site population located within 50 miles. Although the SARs are appropriate methods for studyingmore » individual facility risks, there is a class of accident initiators that can simultaneously affect several of all of the facilities, Examples include seismic events, strong winds or tornados, floods, and loss of off-site electrical power. Overall risk to the off-site population from such initiators is not covered by the individual SARs. In such cases multiple facility radionuclide or chemical releases could occur, and off-site exposure would be greater than that indicated in a single facility SAR. As a step towards an overall site-wide risk model that adequately addresses multiple facility releases, a site-wide seismic model for determining off-site risk has been developed for nuclear facilities at the SRS. Risk from seismic events up to the design basis earthquake (DBE) of 0.2 g (frequency of 2.0E-4/yr) is covered by the model. Present plans include expanding the scope of the model to include other types of initiators that can simultaneously affect multiple facilities.« less

  11. FACILITY LAYOUT OF FUEL STORAGE BUILDING (CPP603) SHOWING STORAGE BASINS, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    FACILITY LAYOUT OF FUEL STORAGE BUILDING (CPP-603) SHOWING STORAGE BASINS, FUEL ELEMENT CUTTING FACILITY, AND DRY GRAPHITE STORAGE FACILITY. INL DRAWING NUMBER 200-0603-00-030-056329. - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID

  12. Antibiotic Stewardship Programs in U.S. Acute Care Hospitals: Findings From the 2014 National Healthcare Safety Network Annual Hospital Survey.

    PubMed

    Pollack, Lori A; van Santen, Katharina L; Weiner, Lindsey M; Dudeck, Margaret A; Edwards, Jonathan R; Srinivasan, Arjun

    2016-08-15

    The National Action Plan to Combat Antibiotic Resistant Bacteria calls for all US hospitals to improve antibiotic prescribing as a key prevention strategy for resistance and Clostridium difficile Antibiotic stewardship programs (ASPs) will be important in this effort but implementation is not well understood. We analyzed the 2014 National Healthcare Safety Network Annual Hospital Survey to describe ASPs in US acute care hospitals as defined by the Center for Disease Control and Prevention's (CDC) Core Elements for Hospital ASPs. Univariate analyses were used to assess stewardship infrastructure and practices by facility characteristics and a multivariate model determined factors associated with meeting all ASP core elements. Among 4184 US hospitals, 39% reported having an ASP that met all 7 core elements. Although hospitals with greater than 200 beds (59%) were more likely to have ASPs, 1 in 4 (25%) of hospitals with less than 50 beds reported achieving all 7 CDC-defined core elements of a comprehensive ASP. The percent of hospitals in each state that reported all seven elements ranged from 7% to 58%. In the multivariate model, written support (adjusted relative risk [RR] 7.2 [95% confidence interval [CI], 6.2-8.4]; P < .0001) or salary support (adjusted RR 1.5 [95% CI, 1.4-1.6]; P < .0001) were significantly associated with having a comprehensive ASP. Our findings show that ASP implementation varies across the United States and provide a baseline to monitor progress toward national goals. Comprehensive ASPs can be established in facilities of any size and hospital leadership support for antibiotic stewardship appears to drive the establishment of ASPs. Published by Oxford University Press for the Infectious Diseases Society of America 2016. This work is written by (a) US Government employee(s) and is in the public domain in the US.

  13. R2 TRI facilities with 1999-2011 risk related estimates throughout the census blockgroup

    EPA Pesticide Factsheets

    This dataset delineates the distribution of estimate risk from the TRI facilities for 1999 - 2011 throughout the census blockgroup of the region using Office of Pollution, Prevention & Toxics (OPPT)'s Risk-Screening Environmental Indicators model (RSEI). The model uses the reported quantities of TRI releases of chemicals to estimate the impacts associated with each type of air release or transfer by every TRI facility.The RSEI was run to generate the estimate risk for each TRI facility in the region. The result from the model is joined to the TRI spatial data. Estimate risk values for each census block group were calculated based on the inverse distance of all the facilities which are within a 50 km radius of the census block group centroid. The estimate risk value for each census block group thus is an aggregated value that takes into account the estimate potential risk of all the facilities within the searching radius (50km).

  14. Contamination by trace elements at e-waste recycling sites in Bangalore, India.

    PubMed

    Ha, Nguyen Ngoc; Agusa, Tetsuro; Ramu, Karri; Tu, Nguyen Phuc Cam; Murata, Satoko; Bulbule, Keshav A; Parthasaraty, Peethmbaram; Takahashi, Shin; Subramanian, Annamalai; Tanabe, Shinsuke

    2009-06-01

    The recycling and disposal of electronic waste (e-waste) in developing countries is causing an increasing concern due to its effects on the environment and associated human health risks. To understand the contamination status, we measured trace elements (TEs) in soil, air dust, and human hair collected from e-waste recycling sites (a recycling facility and backyard recycling units) and the reference sites in Bangalore and Chennai in India. Concentrations of Cu, Zn, Ag, Cd, In, Sn, Sb, Hg, Pb, and Bi were higher in soil from e-waste recycling sites compared to reference sites. For Cu, Sb, Hg, and Pb in some soils from e-waste sites, the levels exceeded screening values proposed by US Environmental Protection Agency (EPA). Concentrations of Cr, Mn, Co, Cu, In, Sn, Sb, Tl, Pb and Bi in air from the e-waste recycling facility were relatively higher than the levels in Chennai city. High levels of Cu, Mo, Ag, Cd, In, Sb, Tl, and Pb were observed in hair of male workers from e-waste recycling sites. Our results suggest that e-waste recycling and its disposal may lead to the environmental and human contamination by some TEs. To our knowledge, this is the first study on TE contamination at e-waste recycling sites in Bangalore, India.

  15. Research of energy characteristics of power amplifier containing KNFS Nd:phosphate glass slabs and MIRO Silver foil reflectors at the “Luch” facility

    NASA Astrophysics Data System (ADS)

    Belov, I. A.; Bel'kov, S. A.; Voronich, I. N.; Garanin, S. G.; Derkach, V. N.; Koshechkin, S. V.; Lysov, M. I.; Markov, S. S.; Savkin, S. V.

    2016-09-01

    The amplifier elements upgrade at the “Luch” laser facility was carried out. Measurements showed that the upgrade of the amplifier elements resulted in the amplifier's small signal gain coefficient K0 increase from 12.9% to 14.3% depending on the capacitor charging voltage; the linear gain coefficient increase was about g0 ≈ (6-8)%. Full-scale laser experiments at the facility showed the power amplifier gain coefficient increase consistent with active medium gain coefficient measurement results.

  16. 20 CFR 655.1115 - Element V-What does “no strike/lockout or layoff” mean?

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... Facility Meet to Employ H-1C Nonimmigrant Workers as Registered Nurses? § 655.1115 Element V—What does “no... not lay off a registered nurse employed by the facility within the period beginning 90 days before and... intended or designated to influence an election for a bargaining representative for registered nurses of...

  17. 20 CFR 655.1115 - Element V-What does “no strike/lockout or layoff” mean?

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... Facility Meet to Employ H-1C Nonimmigrant Workers as Registered Nurses? § 655.1115 Element V—What does “no... not lay off a registered nurse employed by the facility within the period beginning 90 days before and... intended or designated to influence an election for a bargaining representative for registered nurses of...

  18. Who delivers where? The effect of obstetric risk on facility delivery in East Africa.

    PubMed

    Virgo, Sandra; Gon, Giorgia; Cavallaro, Francesca L; Graham, Wendy; Woodd, Susannah

    2017-09-01

    Skilled attendance at birth is key for the survival of pregnant women. This study investigates whether women at increased risk of maternal and newborn complications in four East African countries are more likely to deliver in a health facility than those at lower risk. Demographic and Health Survey data for Kenya 2014, Rwanda 2014-15, Tanzania 2015-16 and Uganda 2011 were used to study women with a live birth in the three years preceding the survey. A three-level obstetric risk index was created using known risk factors. Generalised linear Poisson regression was used to investigate the association between obstetric risk and facility delivery. We analysed data from 13 119 women across the four countries of whom 42-45% were considered at medium risk and 12-17% at high risk, and the remainder were at low risk. In Rwanda, 93% of all women delivered in facilities but this was lower (59-66%) in the other three countries. There was no association between a woman's obstetric risk level and her place of delivery in any country; greater wealth and more education were, however, independently strongly associated with facility delivery. In four East African countries, women at higher obstetric risk were not more likely to deliver in a facility than those with lower risk. This calls for a renewed focus on antenatal risk screening and improved communication on birth planning to ensure women with an increased chance of maternal and newborn complications are supported to deliver in facilities with skilled care. © 2017 John Wiley & Sons Ltd.

  19. Facility-Level Characteristics Associated with Serious Suicide Attempts and Deaths from Suicide in Juvenile Justice Residential Facilities

    ERIC Educational Resources Information Center

    Gallagher, Catherine A.; Dobrin, Adam

    2006-01-01

    Little is known about how facility-level characteristics affect the risk of suicide and suicide attempts in juvenile justice residential facilities. This leaves facility administrators and mental health providers without evidence-based guidance on how the facility itself affects risks. The current study uses data from two recently developed…

  20. Environmental review of Potomac Electric Power Company's proposed Station H Element I

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1990-04-01

    The report has been conducted to evaluate the potential impacts to environmental and cultural resources from the proposed construction and operation of Element I (the combustion turbine portion) of the Station H power plant facility at Potomac Electric Power Company's Dickerson site. This review also presents an evaluation of air quality impacts of Elements I and II (combustion turbine and combined cycle components of the facility) and an assessment of compliance with state and Federal air quality regulations (primarily the ambient air quality standards and the air quality impact requirements of PSD regulations). Results of the Environmental Review analysis aremore » used as the basis for establishing preliminary recommended licensing conditions for operating the proposed facility. These recommendations are also included in the report.« less

  1. Fifth anniversary of the first element of the International Spac

    NASA Image and Video Library

    2003-12-03

    In the Space Station Processing Facility, (from left) David Bethay, Boeing/ISS Florida Operations; Charlie Precourt, deputy manager of the International Space Station Program; and Tip Talone, director of Space Station and Payload Processing, give an overview of Space Station processing for the media. Members of the media were invited to commemorate the fifth anniversary of the launch of the first element of the International Space Station by touring the Space Station Processing Facility (SSPF) at KSC. Reporters also had the opportunity to see Space Station hardware that is being processed for deployment once the Space Shuttles return to flight. The facility tour also included an opportunity for reporters to talk with NASA and Boeing mission managers about the various hardware elements currently being processed for flight.

  2. James Webb Space Telescope (JWST) Integrated Science Instruments Module (ISIM) Cryo-Vacuum (CV) Test Campaign Summary

    NASA Technical Reports Server (NTRS)

    Yew, Calinda; Lui, Yan; Whitehouse, Paul; Banks, Kimberly

    2016-01-01

    JWST Integrated Science Instruments Module (ISIM) completed its system-level space simulation testing program at the NASA Goddard Space Flight Center (GSFC). In March 2016, ISIM was successfully delivered to the next level of integration with the Optical Telescope Element (OTE), to form OTIS (OTE + ISIM), after concluding a series of three cryo-vacuum (CV) tests. During these tests, the complexity of the mission has generated challenging requirements that demand highly reliable system performance and capabilities from the Space Environment Simulator (SES) vacuum chamber. The first test served as a risk reduction test; the second test provided the initial verification of the fully-integrated flight instruments; and the third test verified the system in its final flight configuration following mechanical environmental tests (vibration and acoustics). From one test to the next, shortcomings of the facility were uncovered and associated improvements in operational capabilities and reliability of the facility were required to enable the project to verify system-level requirements. This paper: (1) provides an overview of the integrated mechanical and thermal facility systems required to achieve the objectives of JWST ISIM testing, (2) compares the overall facility performance and instrumentation results from the three ISIM CV tests, and (3) summarizes lessons learned from the ISIM testing campaign.

  3. Environmental justice: frequency and severity of US chemical industry accidents and the socioeconomic status of surrounding communities.

    PubMed

    Elliott, M R; Wang, Y; Lowe, R A; Kleindorfer, P R

    2004-01-01

    The Clean Air Act Amendments of 1990 requires that chemical facilities in the US with specified quantities of certain toxic or flammable chemicals file a five year history of accidents. This study considers the relation between the reported accidents and surrounding community characteristics. This study is a retrospective analysis of the association between the demographics of counties in which facilities are located and the risk of accidental chemical release and resulting injuries at those facilities. The "location risk" (the risk that a facility having large volumes of hazardous chemicals is located in a community) and "operations risk" (the risk of an accident itself) are investigated. 1994-2000 accident history data from 15 083 US industrial facilities using one or more of 140 flammable or toxic substances above a threshold level. Demographic makeup of 2333 counties surrounding these facilities was determined from the 1990 US census. Larger and more chemical intensive facilities tend to be located in counties with larger African-American populations and in counties with both higher median incomes and high levels of income inequality. Even after adjusting for location risk there is greater risk of accidents for facilities in heavily African-American counties (OR of accident = 1.9, 95% CI = 1.5 to 2.4). Further research and policy interventions are required to reduce the probability of locating facilities in an inequitable fashion, as well as health surveillance, and regulatory monitoring and enforcement activities to ensure that hazardous facilities in minority communities prepare and prevent accidental chemical releases to the same standards as elsewhere.

  4. Nuclear Thermal Rocket Element Environmental Simulator (NTREES) Phase II Upgrade Activities

    NASA Technical Reports Server (NTRS)

    Emrich, William J.; Moran, Robert P.; Pearson, J. Bose

    2013-01-01

    To support the on-going nuclear thermal propulsion effort, a state-of-the-art non nuclear experimental test setup has been constructed to evaluate the performance characteristics of candidate fuel element materials and geometries in representative environments. The facility to perform this testing is referred to as the Nuclear Thermal Rocket Element Environment Simulator (NTREES). This device can simulate the environmental conditions (minus the radiation) to which nuclear rocket fuel components will be subjected during reactor operation. Test articles mounted in the simulator are inductively heated in such a manner so as to accurately reproduce the temperatures and heat fluxes which would normally occur as a result of nuclear fission and would be exposed to flowing hydrogen. Initial testing of a somewhat prototypical fuel element has been successfully performed in NTREES and the facility has now been shutdown to allow for an extensive reconfiguration of the facility which will result in a significant upgrade in its capabilities. Keywords: Nuclear Thermal Propulsion, Simulator

  5. 30 CFR 254.3 - May I cover more than one facility in my response plan?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ..., DEPARTMENT OF THE INTERIOR OFFSHORE OIL-SPILL RESPONSE REQUIREMENTS FOR FACILITIES LOCATED SEAWARD OF THE... Plans must address all the elements required for a response plan in Subpart B, Oil Spill Response Plans for Outer Continental Shelf Facilities, or Subpart D, Oil Spill Response Requirements for Facilities...

  6. 30 CFR 254.3 - May I cover more than one facility in my response plan?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ..., DEPARTMENT OF THE INTERIOR OFFSHORE OIL-SPILL RESPONSE REQUIREMENTS FOR FACILITIES LOCATED SEAWARD OF THE... Plans must address all the elements required for a response plan in Subpart B, Oil Spill Response Plans for Outer Continental Shelf Facilities, or Subpart D, Oil Spill Response Requirements for Facilities...

  7. 30 CFR 254.3 - May I cover more than one facility in my response plan?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ..., DEPARTMENT OF THE INTERIOR OFFSHORE OIL-SPILL RESPONSE REQUIREMENTS FOR FACILITIES LOCATED SEAWARD OF THE... Plans must address all the elements required for a response plan in Subpart B, Oil Spill Response Plans for Outer Continental Shelf Facilities, or Subpart D, Oil Spill Response Requirements for Facilities...

  8. How to develop a standard operating procedure for sorting unfixed cells.

    PubMed

    Schmid, Ingrid

    2012-07-01

    Written standard operating procedures (SOPs) are an important tool to assure that recurring tasks in a laboratory are performed in a consistent manner. When the procedure covered in the SOP involves a high-risk activity such as sorting unfixed cells using a jet-in-air sorter, safety elements are critical components of the document. The details on sort sample handling, sorter set-up, validation, operation, troubleshooting, and maintenance, personal protective equipment (PPE), and operator training, outlined in the SOP are to be based on careful risk assessment of the procedure. This review provides background information on the hazards associated with sorting of unfixed cells and the process used to arrive at the appropriate combination of facility design, instrument placement, safety equipment, and practices to be followed. Copyright © 2012 Elsevier Inc. All rights reserved.

  9. Spacelab Data Processing Facility (SLDPF) quality assurance expert systems development

    NASA Technical Reports Server (NTRS)

    Kelly, Angelita C.; Basile, Lisa; Ames, Troy; Watson, Janice; Dallam, William

    1987-01-01

    Spacelab Data Processing Facility (SLDPF) expert system prototypes were developed to assist in the quality assurance of Spacelab and/or Attached Shuttle Payload (ASP) processed telemetry data. The SLDPF functions include the capturing, quality monitoring, processing, accounting, and forwarding of mission data to various user facilities. Prototypes for the two SLDPF functional elements, the Spacelab Output Processing System and the Spacelab Input Processing Element, are described. The prototypes have produced beneficial results including an increase in analyst productivity, a decrease in the burden of tedious analyses, the consistent evaluation of data, and the providing of concise historical records.

  10. Spacelab Data Processing Facility (SLDPF) quality assurance expert systems development

    NASA Technical Reports Server (NTRS)

    Kelly, Angelita C.; Basile, Lisa; Ames, Troy; Watson, Janice; Dallam, William

    1987-01-01

    Spacelab Data Processing Facility (SLDPF) expert system prototypes have been developed to assist in the quality assurance of Spacelab and/or Attached Shuttle Payload (ASP) processed telemetry data. SLDPF functions include the capturing, quality monitoring, processing, accounting, and forwarding of mission data to various user facilities. Prototypes for the two SLDPF functional elements, the Spacelab Output Processing System and the Spacelab Input Processing Element, are described. The prototypes have produced beneficial results including an increase in analyst productivity, a decrease in the burden of tedious analyses, the consistent evaluation of data, and the providing of concise historical records.

  11. Fabless company mask technology approach: fabless but not fab-careless

    NASA Astrophysics Data System (ADS)

    Hisamura, Toshiyuki; Wu, Xin

    2009-10-01

    There are two different foundry-fabless working models in the aspect of mask. Some foundries have in-house mask facility while others contract with merchant mask vendors. Significant progress has been made in both kinds of situations. Xilinx as one of the pioneers of fabless semiconductor companies has been continually working very closely with both merchant mask vendors and mask facilities of foundries in past many years, contributed well in both technology development and benefited from corporations. Our involvement in manufacturing is driven by the following three elements: The first element is to understand the new fabrication and mask technologies and then find a suitable design / layout style to better utilize these new technologies and avoid potential risks. Because Xilinx has always been involved in early stage of advanced technology nodes, this early understanding and adoption is especially important. The second element is time to market. Reduction in mask and wafer manufacturing cycle-time can ensure faster time to market. The third element is quality. Commitment to quality is our highest priority for our customers. We have enough visibility on any manufacturing issues affecting the device functionality. Good correlation has consistently been observed between FPGA speed uniformity and the poly mask Critical Dimension (CD) uniformity performance. To achieve FPGA speed uniformity requirement, the manufacturing process as well as the mask and wafer CD uniformity has to be monitored. Xilinx works closely with the wafer foundries and mask suppliers to improve productivity and the yield from initial development stage of mask making operations. As an example, defect density reduction is one of the biggest challenges for mask supplier in development stage to meet the yield target satisfying the mask cost and mask turn-around-time (TAT) requirement. Historically, masks were considered to be defect free but at these advanced process nodes, that assumption no longer holds true. There is a need to be flexible enough on unrepairable defect at early stage but also a need for efficient risk management system on mask defect waivers. Mask defects are often waived in low design criticality area in favor of scrapping the mask and delaying the mask and wafer schedule. Xilinx's involvement in mask manufacturing has contributed significantly to our success in past many nodes and will continue.

  12. RCRA Facility Investigation/Remedial Investigation Report with Baseline Risk Assessment for the Fire Department Hose Training Facility (904-113G)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Palmer, E.

    1997-04-01

    This report documents the Resource Conservation and Recovery Act (RCRA) Facility Investigation/Remedial Investigation/Baseline Risk Assessment (RFI/RI/BRA) for the Fire Department Hose Training Facility (FDTF) (904-113G).

  13. Final Long-Term Management and Storage of Elemental Mercury Environmental Impact Statement Volume1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    2011-01-01

    Pursuant to the Mercury Export Ban Act of 2008 (P.L. 110-414), DOE was directed to designate a facility or facilities for the long-term management and storage of elemental mercury generated within the United States. Therefore, DOE has analyzed the storage of up to 10,000 metric tons (11,000 tons) of elemental mercury in a facility(ies) constructed and operated in accordance with the Solid Waste Disposal Act, as amended by the Resource Conservation and Recovery Act (74 FR 31723).DOE prepared this Final Mercury Storage EIS in accordance with the National Environmental Policy Act of 1969 (NEPA), as amended (42 U.S.C. 4321 etmore » seq.), the Council on Environmental Quality (CEQ) implementing regulations (40 CFR 1500–1508), and DOE’s NEPA implementing procedures (10 CFR 1021) to evaluate reasonable alternatives for a facility(ies) for the long-term management and storage of elemental mercury. This Final Mercury Storage EIS analyzes the potential environmental, human health, and socioeconomic impacts of elemental mercury storage at seven candidate locations:Grand Junction Disposal Site near Grand Junction, Colorado; Hanford Site near Richland, Washington; Hawthorne Army Depot near Hawthorne, Nevada; Idaho National Laboratory near Idaho Falls, Idaho;Kansas City Plant in Kansas City, Missouri; Savannah River Site near Aiken, South Carolina; and Waste Control Specialists, LLC, site near Andrews, Texas. As required by CEQ NEPA regulations, the No Action Alternative was also analyzed as a basis for comparison. DOE intends to decide (1) where to locate the elemental mercury storage facility(ies) and (2) whether to use existing buildings, new buildings, or a combination of existing and new buildings. DOE’s Preferred Alternative for the long-term management and storage of mercury is the Waste Control Specialists, LLC, site near Andrews, Texas.« less

  14. Final Long-Term Management and Storage of Elemental Mercury Environmental Impact Statement Volume 2

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    Pursuant to the Mercury Export Ban Act of 2008 (P.L. 110-414), DOE was directed to designate a facility or facilities for the long-term management and storage of elemental mercury generated within the United States. Therefore, DOE has analyzed the storage of up to 10,000 metric tons (11,000 tons) of elemental mercury in a facility(ies) constructed and operated in accordance with the Solid Waste Disposal Act, as amended by the Resource Conservation and Recovery Act (74 FR 31723). DOE prepared this Final Mercury Storage EIS in accordance with the National Environmental Policy Act of 1969 (NEPA), as amended (42 U.S.C. 4321more » et seq.), the Council on Environmental Quality (CEQ) implementing regulations (40 CFR 1500–1508), and DOE’s NEPA implementing procedures (10 CFR 1021) to evaluate reasonable alternatives for a facility(ies) for the long-term management and storage of elemental mercury. This Final Mercury Storage EIS analyzes the potential environmental, human health, and socioeconomic impacts of elemental mercury storage at seven candidate locations: Grand Junction Disposal Site near Grand Junction, Colorado; Hanford Site near Richland, Washington; Hawthorne Army Depot near Hawthorne, Nevada; Idaho National Laboratory near Idaho Falls, Idaho; Kansas City Plant in Kansas City, Missouri; Savannah River Site near Aiken, South Carolina; and Waste Control Specialists, LLC, site near Andrews, Texas. As required by CEQ NEPA regulations, the No Action Alternative was also analyzed as a basis for comparison. DOE intends to decide (1) where to locate the elemental mercury storage facility(ies) and (2) whether to use existing buildings, new buildings, or a combination of existing and new buildings. DOE’s Preferred Alternative for the long-term management and storage of mercury is the Waste Control Specialists, LLC, site near Andrews, Texas.« less

  15. Identifying elements of the health care environment that contribute to wayfinding.

    PubMed

    Pati, Debajyoti; Harvey, Thomas E; Willis, Douglas A; Pati, Sipra

    2015-01-01

    Identify aspects of the physical environment that inform wayfinding for visitors. Compare and contrast the identified elements in frequency of use. Gain an understanding of the role the different elements and attributes play in the wayfinding process. Wayfinding by patients and visitors is a documented problem in healthcare facilities. The few studies that have been conducted have identified some of the environmental elements that influence wayfinding. Moreover, literatures comparing different design strategies are absent. Currently there is limited knowledge to inform prioritization of strategies to optimize wayfinding within capital budget. A multi-method, non-experimental, qualitative, exploratory study design was adopted. The study was conducted in a large, acute care facility in Texas. Ten healthy adults in five age groups, representing both sexes, participated in the study as simulated visitors. Data collection included (a) verbal protocols during navigation; (b) questionnaire; and (c) verbal directions from hospital employees. Data were collected during Fall 2013. Physical design elements contributing to wayfinding include signs, architectural features, maps, interior elements (artwork, display boards, information counters, etc.), functional clusters, interior elements pairing, structural elements, and furniture. The information is used in different ways - some for primary navigational information, some for supporting navigational information, and some as familiarity markers. The physical environment has a critical role in aiding navigation in healthcare facilities. Architectural feature is the top contributor in the domain of architecture. Artwork (painting, sculpture, etc.) is the top contributor in the domain of interior design. © The Author(s) 2015.

  16. Health and safety programs for art and theater schools.

    PubMed

    McCann, M

    2001-01-01

    A wide variety of health and safety hazards exist in schools and colleges of art and theater due to a lack of formal health and safety programs and a failure to include health and safety concerns during planning of new facilities and renovation of existing facilities. This chapter discusses the elements of a health and safety program as well as safety-related structural and equipment needs that should be in the plans for any school of art or theater. These elements include curriculum content, ventilation, storage, housekeeping, waste management, fire and explosion prevention, machine and tool safety, electrical safety, noise, heat stress, and life safety and emergency procedures and equipment. Ideally, these elements should be incorporated into the plans for any new facilities, but ongoing programs can also benefit from a review of existing health and safety programs.

  17. Physical, chemical, and biological characteristics of the Boise River from Veterans Memorial Parkway, Boise to Star, Idaho, October 1987 to March 1988

    USGS Publications Warehouse

    Frenzel, S.A.

    1988-01-01

    Physical, chemical, and biological characteristics of the Boise River were examined from October 1987 to March 1988 to determine whether trace elements in effluents from two Boise wastewater treatment facilities were detrimental to aquatic communities. Cadmium, chromium, hexavalent chromium, cyanide, lead, nickel, and silver concentrations in the Boise River were less than or near analytical detection levels and were less than chronic toxicity criteria when detectable. Arsenic, copper, and zinc were detected in concentrations less than chronic toxicity criteria. Concentrations of trace elements in bottom material generally were small and could not be attributed to effluents from wastewater treatment facilities. From October to December 1987, mean density of benthic invertebrates colonizing artificial substrates was from 6,100 individuals/substrate downstream from the West Boise wastewater treatment facility to 14,000 individuals per substrate downstream from the Lander Street wastewater treatment facility. From January to March 1988 , mean density of benthic invertebrates colonizing artificial substrates was from 7,100 individuals per substrate downstream from the West Boise facility to 10,000 individuals per substrate near Star. Insect communities upstream and downstream from the wastewater treatment facilities were strongly associated, and coeffients of community loss indicated that effluents had benign enriching effects. Distribution of mayflies indicates that trace-element concentrations in effluents did not adversely affect intolerant organisms in the Boise River. Condition factor of whitefish was significantly increased downstream from the Lander Street wastewater treatment facility and was significantly decreased downstream from the West Boise wastewater treatment facility.

  18. Environmental justice: frequency and severity of US chemical industry accidents and the socioeconomic status of surrounding communities

    PubMed Central

    Elliott, M; Wang, Y; Lowe, R; Kleindorfer, P

    2004-01-01

    Study objectives: The Clean Air Act Amendments of 1990 requires that chemical facilities in the US with specified quantities of certain toxic or flammable chemicals file a five year history of accidents. This study considers the relation between the reported accidents and surrounding community characteristics. Design: This study is a retrospective analysis of the association between the demographics of counties in which facilities are located and the risk of accidental chemical release and resulting injuries at those facilities. The "location risk" (the risk that a facility having large volumes of hazardous chemicals is located in a community) and "operations risk" (the risk of an accident itself) are investigated. Setting:1994–2000 accident history data from 15 083 US industrial facilities using one or more of 140 flammable or toxic substances above a threshold level. Demographic makeup of 2333 counties surrounding these facilities was determined from the 1990 US census. Main results: Larger and more chemical intensive facilities tend to be located in counties with larger African-American populations and in counties with both higher median incomes and high levels of income inequality. Even after adjusting for location risk there is greater risk of accidents for facilities in heavily African-American counties (OR of accident = 1.9, 95% CI = 1.5 to 2.4). Conclusions: Further research and policy interventions are required to reduce the probability of locating facilities in an inequitable fashion, as well as health surveillance, and regulatory monitoring and enforcement activities to ensure that hazardous facilities in minority communities prepare and prevent accidental chemical releases to the same standards as elsewhere. PMID:14684723

  19. The confusion in complying with good manufacturing practice requirements in Malaysia

    NASA Astrophysics Data System (ADS)

    Jali, Mohd Bakri; Ghani, Maaruf Abdul; Nor, Norazmir Md

    2016-11-01

    Food manufacturing operations need to fulfil regulatory requirements related to hygiene and good manufacturing practices (GMP) to successfully market their products as safe and quality products. GMP based on its ten elements used as guidelines to ensure control over biological, chemical and physical hazards. This study aims to investigate the confusion for design and facilities elements among food industries. Both qualitative and quantitative techniques are used as systematic tools. Design and facilities elements lay a firm foundation for good manufacturing practice to ensure food hygiene and should be used in conjunction with each specific code of hygiene practice and guidelines.

  20. Fifth anniversary of the first element of the International Spac

    NASA Image and Video Library

    2003-12-03

    In the Space Station Processing Facility (SSPF), Charles J. Precourt, deputy manager of NASA's International Space Station Program, is interviewed by a reporter from a local television station. Representatives from the media were invited to commemorate the fifth anniversary of the launch of the first element of the Station with a tour of the facility and had the opportunity to see Space Station hardware that is being processed for deployment once the Space Shuttles return to flight. NASA and Boeing mission managers were on hand to talk about the various hardware elements currently being processed for flight.

  1. [Evolution of work duties in manufacturing activities].

    PubMed

    Guerra, F

    2001-01-01

    The present work deals with duties' evolution according to the aspect of the investment's increase in facilities and equipment for employ, of industry-wide agreement, of cost accounting, of added value, of plant lay-out, of job competence and of production technologies. The mutual relation between duties and risk of cumulative trauma disorders is studied in qualitative and quantitative way making use of active and waiting labour time allotment during the labour cycle, rest and fatigue factor, labour losses, collective and individual breaks, high repeated work and worked items' variability. In conclusion the paper presents elements and examples about investments in automation and organisation with relay-out.

  2. AIAA Aerospace America Magazine - Year in Review Article, 2010

    NASA Technical Reports Server (NTRS)

    Figueroa, Fernando

    2010-01-01

    NASA Stennis Space Center has implemented a pilot operational Integrated System Health Management (ISHM) capability. The implementation was done for the E-2 Rocket Engine Test Stand and a Chemical Steam Generator (CSG) test article; and validated during operational testing. The CSG test program is a risk mitigation activity to support building of the new A-3 Test Stand, which will be a highly complex facility for testing of engines in high altitude conditions. The foundation of the ISHM capability are knowledge-based integrated domain models for the test stand and CSG, with physical and model-based elements represented by objects the domain models enable modular and evolutionary ISHM functionality.

  3. ART Attrition across Health Facilities Implementing Option B+ in Haiti.

    PubMed

    Myrtil, Martine Pamphile; Puttkammer, Nancy; Gloyd, Stephen; Robinson, Julia; Yuhas, Krista; Domercant, Jean Wysler; Honoré, Jean Guy; Francois, Kesner

    2018-01-01

    Describing factors related to high attrition is important in order to improve the implementation of the Option B+ strategy in Haiti. We conducted a retrospective cohort study to describe the variability of antiretroviral therapy (ART) retention across health facilities among pregnant and lactating women and assess for differences in ART retention between Option B+ clients and other ART patients. There were 1989 Option B+ clients who initiated ART in 45 health facilities. The percentage of attrition varied from 9% to 81% across the facilities. The largest health facilities had 38% higher risk of attrition (relative risk [RR]: 1.38, 95% confidence interval [CI]: 1.08-1.77, P = .009). Private institutions had 18% less risk of attrition (RR: 0.82, 95% CI: 0.70-0.96, P = .020). Health facilities located in the West department and the South region had lower risk of attrition. Being on treatment in a large or public health facility or a facility located in the North region was a significant risk factor associated with high attrition among Option B+ clients. The implementation of the Option B+ strategy must be reevaluated in order to effectively eliminate mother-to-child HIV transmission.

  4. Government conceptual estimating for contracting and management

    NASA Technical Reports Server (NTRS)

    Brown, J. A.

    1986-01-01

    The use of the Aerospace Price Book, a cost index, and conceptual cost estimating for cost-effective design and construction of space facilities is discussed. The price book consists of over 200 commonly used conceptual elements and 100 systems summaries of projects such as launch pads, processing facilities, and air locks. The cost index is composed of three divisions: (1) bid summaries of major Shuttle projects, (2) budget cost data sheets, and (3) cost management summaries; each of these divisions is described. Conceptual estimates of facilities and ground support equipment are required to provide the most probable project cost for budget, funding, and project approval purposes. Similar buildings, systems, and elements already designed are located in the cost index in order to make the best rough order of magnitude conceptual estimates for development of Space Shuttle facilities. An example displaying the applicability of the conceptual cost estimating procedure for the development of the KSC facilities is presented.

  5. Personnel reliability impact on petrochemical facilities monitoring system's failure skipping probability

    NASA Astrophysics Data System (ADS)

    Kostyukov, V. N.; Naumenko, A. P.

    2017-08-01

    The paper dwells upon urgent issues of evaluating impact of actions conducted by complex technological systems operators on their safe operation considering application of condition monitoring systems for elements and sub-systems of petrochemical production facilities. The main task for the research is to distinguish factors and criteria of monitoring system properties description, which would allow to evaluate impact of errors made by personnel on operation of real-time condition monitoring and diagnostic systems for machinery of petrochemical facilities, and find and objective criteria for monitoring system class, considering a human factor. On the basis of real-time condition monitoring concepts of sudden failure skipping risk, static and dynamic error, monitoring systems, one may solve a task of evaluation of impact that personnel's qualification has on monitoring system operation in terms of error in personnel or operators' actions while receiving information from monitoring systems and operating a technological system. Operator is considered as a part of the technological system. Although, personnel's behavior is usually a combination of the following parameters: input signal - information perceiving, reaction - decision making, response - decision implementing. Based on several researches on behavior of nuclear powers station operators in USA, Italy and other countries, as well as on researches conducted by Russian scientists, required data on operator's reliability were selected for analysis of operator's behavior at technological facilities diagnostics and monitoring systems. The calculations revealed that for the monitoring system selected as an example, the failure skipping risk for the set values of static (less than 0.01) and dynamic (less than 0.001) errors considering all related factors of data on reliability of information perception, decision-making, and reaction fulfilled is 0.037, in case when all the facilities and error probability are under control - not more than 0.027. In case when only pump and compressor units are under control, the failure skipping risk is not more than 0.022, when the probability of error in operator's action is not more than 0.011. The work output shows that on the basis of the researches results an assessment of operators' reliability can be made in terms of almost any kind of production, but considering only technological capabilities, since operators' psychological and general training considerable vary in different production industries. Using latest technologies of engineering psychology and design of data support systems, situation assessment systems, decision-making and responding system, as well as achievement in condition monitoring in various production industries one can evaluate hazardous condition skipping risk probability considering static, dynamic errors and human factor.

  6. Elemental properties of coal slag and measured airborne exposures at two coal slag processing facilities

    PubMed Central

    Mugford, Christopher; Boylstein, Randy; Gibbs, Jenna L

    2017-01-01

    In 1974, the National Institute for Occupational Safety and Health recommended a ban on the use of silica sand abrasives containing >1% silica due to the risk of silicosis. This gave rise to substitutes including coal slag. An Occupational Safety and Health Administration investigation in 2010 uncovered a case cluster of suspected pneumoconiosis in four former workers at a coal slag processing facility in Illinois, possibly attributable to occupational exposure to coal slag dust. This article presents the results from a National Institute for Occupational Safety and Health industrial hygiene survey at the same coal slag processing facility and a second facility. The industrial hygiene survey consisted of the collection of: a) bulk samples of unprocessed coal slag, finished granule product, and settled dust for metals and silica; b) full-shift area air samples for dust, metals, and crystalline silica; and c) full-shift personal air samples for dust, metals, and crystalline silica. Bulk samples consisted mainly of iron, manganese, titanium, and vanadium. Some samples had detectable levels of arsenic, beryllium, cadmium, and cobalt. Unprocessed coal slags from Illinois and Kentucky contained 0.43–0.48% (4,300–4,800 mg/kg) silica. Full-shift area air samples identified elevated total dust levels in the screen (2–38 mg/m3) and bag house (21 mg/m3) areas. Full-shift area air samples identified beryllium, chromium, cobalt, copper, iron, nickel, manganese, and vanadium. Overall, personal air samples for total and respirable dust (0.1–6.6 mg/m3 total; and 0.1–0.4 mg/m3 respirable) were lower than area air samples. All full-shift personal air samples for metals and silica were below published occupational exposure limits. All bulk samples of finished product granules contained less than 1% silica, supporting the claim coal slag may present less risk for silicosis than silica sand. We note that the results presented here are solely from two coal slag processing facilities, and more in-depth air monitoring is needed to better characterize occupational exposure to coal slag dust, metals, and silica at similar facilities. PMID:27808662

  7. Elemental properties of coal slag and measured airborne exposures at two coal slag processing facilities.

    PubMed

    Mugford, Christopher; Boylstein, Randy; Gibbs, Jenna L

    2017-05-01

    In 1974, the National Institute for Occupational Safety and Health recommended a ban on the use of silica sand abrasives containing >1% silica due to the risk of silicosis. This gave rise to substitutes including coal slag. An Occupational Safety and Health Administration investigation in 2010 uncovered a case cluster of suspected pneumoconiosis in four former workers at a coal slag processing facility in Illinois, possibly attributable to occupational exposure to coal slag dust. This article presents the results from a National Institute for Occupational Safety and Health industrial hygiene survey at the same coal slag processing facility and a second facility. The industrial hygiene survey consisted of the collection of: (a) bulk samples of unprocessed coal slag, finished granule product, and settled dust for metals and silica; (b) full-shift area air samples for dust, metals, and crystalline silica; and (c) full-shift personal air samples for dust, metals, and crystalline silica. Bulk samples consisted mainly of iron, manganese, titanium, and vanadium. Some samples had detectable levels of arsenic, beryllium, cadmium, and cobalt. Unprocessed coal slags from Illinois and Kentucky contained 0.43-0.48% (4,300-4,800 mg/kg) silica. Full-shift area air samples identified elevated total dust levels in the screen (2-38 mg/m 3 ) and bag house (21 mg/m 3 ) areas. Full-shift area air samples identified beryllium, chromium, cobalt, copper, iron, nickel, manganese, and vanadium. Overall, personal air samples for total and respirable dust (0.1-6.6 mg/m 3 total; and 0.1-0.4 mg/m 3 respirable) were lower than area air samples. All full-shift personal air samples for metals and silica were below published occupational exposure limits. All bulk samples of finished product granules contained less than 1% silica, supporting the claim coal slag may present less risk for silicosis than silica sand. We note that the results presented here are solely from two coal slag processing facilities, and more in-depth air monitoring is needed to better characterize occupational exposure to coal slag dust, metals, and silica at similar facilities.

  8. Capacity planning for electronic waste management facilities under uncertainty: multi-objective multi-time-step model development.

    PubMed

    Poonam Khanijo Ahluwalia; Nema, Arvind K

    2011-07-01

    Selection of optimum locations for locating new facilities and decision regarding capacities at the proposed facilities is a major concern for municipal authorities/managers. The decision as to whether a single facility is preferred over multiple facilities of smaller capacities would vary with varying priorities to cost and associated risks such as environmental or health risk or risk perceived by the society. Currently management of waste streams such as that of computer waste is being done using rudimentary practices and is flourishing as an unorganized sector, mainly as backyard workshops in many cities of developing nations such as India. Uncertainty in the quantification of computer waste generation is another major concern due to the informal setup of present computer waste management scenario. Hence, there is a need to simultaneously address uncertainty in waste generation quantities while analyzing the tradeoffs between cost and associated risks. The present study aimed to address the above-mentioned issues in a multi-time-step, multi-objective decision-support model, which can address multiple objectives of cost, environmental risk, socially perceived risk and health risk, while selecting the optimum configuration of existing and proposed facilities (location and capacities).

  9. Finite Element Analysis of a NASA National Transonic Facility Wind Tunnel Balance

    NASA Technical Reports Server (NTRS)

    Lindell, Michael C.

    1996-01-01

    This paper presents the results of finite element analyses and correlation studies performed on a NASA National Transonic Facility (NTF) Wind Tunnel balance. In the past NASA has relied primarily on classical hand analyses, coupled with relatively large safety factors, for predicting maximum stresses in wind tunnel balances. Now, with the significant advancements in computer technology and sophistication of general purpose analysis codes, it is more reasonable to pursue finite element analyses of these balances. The correlation studies of the present analyses show very good agreement between the analyses and data measured with strain gages and therefore the studies give higher confidence for using finite element analyses to analyze and optimize balance designs in the future.

  10. Finite Element Analysis of a NASA National Transonic Facility Wide Tunnel Balance

    NASA Technical Reports Server (NTRS)

    Lindell, Michael C. (Editor)

    1999-01-01

    This paper presents the results of finite element analyses and correlation studies performed on a NASA National Transonic Facility (NTF) Wind Tunnel balance. In the past NASA has relied primarily on classical hand analyses, coupled with relatively large safety factors, for predicting maximum stresses in wind tunnel balances. Now, with the significant advancements in computer technology and sophistication of general purpose analysis codes, it is more reasonable to pursue finite element analyses of these balances. The correlation studies of the present analyses show very good agreement between the analyses and data measured with strain gages and therefore the studies give higher confidence for using finite element analyses to analyze and optimize balance designs in the future.

  11. Design and Implementation of a Centralized Model of Clinical Education Within a Statewide Health System.

    PubMed

    Elzy, Pamela Smith

    2016-01-01

    Today's dynamic health care environment is exceedingly complex, and health care facilities across the United States are struggling to respond to changes in technology, health care reimbursement, the Affordable Care Act, and the much-anticipated nursing shortage. Mergers, acquisitions, and integrations are the current health care reality. These are proposed to increase efficiency, efficacy, quality, satisfaction, and safety while effectively reducing cost to the consumer and stabilizing the economy of the health care system. Many of these projects fail to achieve objectives, even years after the formal change in status. Clinical education departments in merged organizations are often operated in the single-facility mindset, or contain an element of the shared services model. They are not truly integrated. Development of skills in complex analysis of current state, identification of desired scope of service and expectations of performance, and articulation of the benefits of the desired future state are all essential to nursing executive practice. This article describes an experience integrating 3 legacy education departments across 21 facilities into a centralized education system. The complexity of integration activities is illustrated and outcome measures of success are discussed. Barriers, facilitators, and risks of the project are identified and evaluated.

  12. Impact of Breast Density Legislation on Breast Cancer Risk Assessment and Supplemental Screening: A Survey of 110 Radiology Facilities.

    PubMed

    Nayak, Lina; Miyake, Kanae K; Leung, Jessica W T; Price, Elissa R; Liu, Yueyi I; Joe, Bonnie N; Sickles, Edward A; Thomas, William R; Lipson, Jafi A; Daniel, Bruce L; Hargreaves, Jonathan; Brenner, R James; Bassett, Lawrence W; Ojeda-Fournier, Haydee; Lindfors, Karen K; Feig, Stephen A; Ikeda, Debra M

    2016-09-01

    Breast density notification laws, passed in 19 states as of October 2014, mandate that patients be informed of their breast density. The purpose of this study is to assess the impact of this legislation on radiology practices, including performance of breast cancer risk assessment and supplemental screening studies. A 20-question anonymous web-based survey was emailed to radiologists in the Society of Breast Imaging between August 2013 and March 2014. Statistical analysis was performed using Fisher's exact test. Around 121 radiologists from 110 facilities in 34 USA states and 1 Canadian site responded. About 50% (55/110) of facilities had breast density legislation, 36% of facilities (39/109) performed breast cancer risk assessment (one facility did not respond). Risk assessment was performed as a new task in response to density legislation in 40% (6/15) of facilities in states with notification laws. However, there was no significant difference in performing risk assessment between facilities in states with a law and those without (p < 0.831). In anticipation of breast density legislation, 33% (16/48), 6% (3/48), and 6% (3/48) of facilities in states with laws implemented handheld whole breast ultrasound (WBUS), automated WBUS, and tomosynthesis, respectively. The ratio of facilities offering handheld WBUS was significantly higher in states with a law than in states without (p < 0.001). In response to breast density legislation, more than 33% of facilities are offering supplemental screening with WBUS and tomosynthesis, and many are performing formal risk assessment for determining patient management. © 2016 Wiley Periodicals, Inc.

  13. Mercury and other trace elements in Ohio River fish collected near coal-fired power plants: Interspecific patterns and consideration of consumption risks.

    PubMed

    Reash, Robin J; Brown, Lauren; Merritt, Karen

    2015-07-01

    Many coal-fired electric generating facilities in the United States are discharging higher loads of Hg, Se, and other chemicals to receiving streams due to the installation of flue gas desulfurization (FGD) air pollution control units. There are regulatory concerns about the potential increased uptake of these bioaccumulative trace elements into food webs. We evaluated the concentrations of As, total Hg (THg), methylmercury (MeHg), and Se in Ohio River fish collected proximal to coal-fired power plants, of which 75% operate FGD systems. Fillet samples (n = 50) from 6 fish species representing 3 trophic levels were analyzed. Geometric mean fillet concentrations of THg (wet wt), MeHg (wet wt), and Se (dry wt) in 3 species were 0.136, 0.1181, and 3.19 mg/kg (sauger); 0.123, 0.1013, and 1.56 mg/kg (channel catfish); and 0.127, 0.0914, and 3.30 mg/kg (hybrid striped bass). For all species analyzed, only 3 fillet samples (6% of total) had MeHg concentrations that exceeded the US Environmental Protection Agency (USEPA) human health criterion (0.3 mg/kg wet wt); all of these were freshwater drum aged ≥ 19 y. None of the samples analyzed exceeded the USEPA proposed muscle and whole body Se thresholds for protection against reproductive effects in freshwater fish. All but 8 fillet samples had a total As concentration less than 1.0 mg/kg dry wt. Mean Se health benefit values (HBVSe ) for all species were ≥ 4, indicating that potential Hg-related health risks associated with consumption of Ohio River fish are likely to be offset by adequate Se concentrations. Overall, we observed no measurable evidence of enhanced trace element bioaccumulation associated with proximity to power plant FGD facilities, however, some enhanced bioaccumulation could have occurred in the wastewater mixing zones. Furthermore, available evidence indicates that, due to hydraulic and physical factors, the main stem Ohio River appears to have low net Hg methylation potential. © 2015 SETAC.

  14. 6 CFR 27.200 - Information regarding security risk for a chemical facility.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 6 Domestic Security 1 2010-01-01 2010-01-01 false Information regarding security risk for a chemical facility. 27.200 Section 27.200 Domestic Security DEPARTMENT OF HOMELAND SECURITY, OFFICE OF THE SECRETARY CHEMICAL FACILITY ANTI-TERRORISM STANDARDS Chemical Facility Security Program § 27.200 Information...

  15. 47 CFR 69.114 - Special access.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) COMMON CARRIER SERVICES (CONTINUED) ACCESS CHARGES... of equipment or facilities that are assigned to the Special Access element for purposes of... requirement for the Special Access element. (c) Charges for an individual element shall be assessed upon all...

  16. Analyses in support of risk-informed natural gas vehicle maintenance facility codes and standards :

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ekoto, Isaac W.; Blaylock, Myra L.; LaFleur, Angela Christine

    2014-03-01

    Safety standards development for maintenance facilities of liquid and compressed gas fueled large-scale vehicles is required to ensure proper facility design and operation envelopes. Standard development organizations are utilizing risk-informed concepts to develop natural gas vehicle (NGV) codes and standards so that maintenance facilities meet acceptable risk levels. The present report summarizes Phase I work for existing NGV repair facility code requirements and highlights inconsistencies that need quantitative analysis into their effectiveness. A Hazardous and Operability study was performed to identify key scenarios of interest. Finally, scenario analyses were performed using detailed simulations and modeling to estimate the overpressure hazardsmore » from HAZOP defined scenarios. The results from Phase I will be used to identify significant risk contributors at NGV maintenance facilities, and are expected to form the basis for follow-on quantitative risk analysis work to address specific code requirements and identify effective accident prevention and mitigation strategies.« less

  17. Risk assessment of CST-7 proposed waste treatment and storage facilities Volume I: Limited-scope probabilistic risk assessment (PRA) of proposed CST-7 waste treatment & storage facilities. Volume II: Preliminary hazards analysis of proposed CST-7 waste storage & treatment facilities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sasser, K.

    1994-06-01

    In FY 1993, the Los Alamos National Laboratory Waste Management Group [CST-7 (formerly EM-7)] requested the Probabilistic Risk and Hazards Analysis Group [TSA-11 (formerly N-6)] to conduct a study of the hazards associated with several CST-7 facilities. Among these facilities are the Hazardous Waste Treatment Facility (HWTF), the HWTF Drum Storage Building (DSB), and the Mixed Waste Receiving and Storage Facility (MWRSF), which are proposed for construction beginning in 1996. These facilities are needed to upgrade the Laboratory`s storage capability for hazardous and mixed wastes and to provide treatment capabilities for wastes in cases where offsite treatment is not availablemore » or desirable. These facilities will assist Los Alamos in complying with federal and state requlations.« less

  18. 33 CFR 127.1205 - Emergency shutdown.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...) WATERFRONT FACILITIES WATERFRONT FACILITIES HANDLING LIQUEFIED NATURAL GAS AND LIQUEFIED HAZARDOUS GAS Waterfront Facilities Handling Liquefied Hazardous Gas Equipment § 127.1205 Emergency shutdown. (a) Each... elements that melt at less than 105 °C (221 °F) and activate the emergency shutdown, or have a sensor that...

  19. 33 CFR 127.1205 - Emergency shutdown.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) WATERFRONT FACILITIES WATERFRONT FACILITIES HANDLING LIQUEFIED NATURAL GAS AND LIQUEFIED HAZARDOUS GAS Waterfront Facilities Handling Liquefied Hazardous Gas Equipment § 127.1205 Emergency shutdown. (a) Each... elements that melt at less than 105 °C (221 °F) and activate the emergency shutdown, or have a sensor that...

  20. 20 CFR 655.1117 - Element VII-What are the limitations as to the number of H-1C nonimmigrants that a facility may...

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... Registered Nurses? § 655.1117 Element VII—What are the limitations as to the number of H-1C nonimmigrants... it will not, at any time, employ a number of H-1C nurses that exceeds 33% of the total number of registered nurses employed by the facility. The calculation of the population of nurses for purposes of this...

  1. Air Vehicles Division Computational Structural Analysis Facilities Policy and Guidelines for Users

    DTIC Science & Technology

    2005-05-01

    34 Thermal " as appropriate and the tolerance set to "default". b) Create the model geometry. c) Create the finite elements. d) Create the...linear, non-linear, dynamic, thermal , acoustic analysis. The modelling of composite materials, creep, fatigue and plasticity are also covered...perform professional, high quality finite element analysis (FEA). FE analysts from many tasks within AVD are using the facilities to conduct FEA with

  2. 20 CFR 655.1117 - Element VII-What are the limitations as to the number of H-1C nonimmigrants that a facility may...

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... the number of H-1C nonimmigrants that a facility may employ? 655.1117 Section 655.1117 Employees... Registered Nurses? § 655.1117 Element VII—What are the limitations as to the number of H-1C nonimmigrants... it will not, at any time, employ a number of H-1C nurses that exceeds 33% of the total number of...

  3. 20 CFR 655.1117 - Element VII-What are the limitations as to the number of H-1C nonimmigrants that a facility may...

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... the number of H-1C nonimmigrants that a facility may employ? 655.1117 Section 655.1117 Employees... Registered Nurses? § 655.1117 Element VII—What are the limitations as to the number of H-1C nonimmigrants... it will not, at any time, employ a number of H-1C nurses that exceeds 33% of the total number of...

  4. 20 CFR 655.1117 - Element VII-What are the limitations as to the number of H-1C nonimmigrants that a facility may...

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... the number of H-1C nonimmigrants that a facility may employ? 655.1117 Section 655.1117 Employees... Registered Nurses? § 655.1117 Element VII—What are the limitations as to the number of H-1C nonimmigrants... it will not, at any time, employ a number of H-1C nurses that exceeds 33% of the total number of...

  5. 20 CFR 655.1117 - Element VII-What are the limitations as to the number of H-1C nonimmigrants that a facility may...

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... the number of H-1C nonimmigrants that a facility may employ? 655.1117 Section 655.1117 Employees... Registered Nurses? § 655.1117 Element VII—What are the limitations as to the number of H-1C nonimmigrants... it will not, at any time, employ a number of H-1C nurses that exceeds 33% of the total number of...

  6. Challenges Associated With Managing Suicide Risk in Long-Term Care Facilities.

    PubMed

    O'Riley, Alisa; Nadorff, Michael R; Conwell, Yeates; Edelstein, Barry

    2013-06-01

    Little information about suicidal ideation and behavior in long-term care (LTC) facilities is available. Nonetheless, the implementation of the Minimum Data Set 3.0 requires that LTC facilities screen their residents for suicide risk and have protocols in place to effectively manage residents' responses. In this article, the authors briefly discuss the risk factors of suicide in the elderly and the problems that suicidal ideation and behavior pose in the LTC environment. The authors explain issues that arise when trying to manage suicide risk in the elderly LTC population with general, traditional approaches. These inherent issues make it difficult to develop an effective protocol for managing suicide risk in LTC facilities, leading the authors to propose their own framework for assessing and managing suicide risk in the LTC setting.

  7. Beam-Dynamics Analysis of Long-Range Wakefield Effects on the SCRF Cavities at the Fast Facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shin, Young-Min; Bishofberger, Kip; Carlsten, Bruce

    Long-range wakefields in superconducting RF (SCRF) cavities create complicated effects on beam dynamics in SCRF-based FEL beamlines. The driving bunch excites effectively an infinite number of structure modes (including HOMs) which oscillate within the SCRF cavity. Couplers with loads are used to damp the HOMs. However, these HOMs can persist for long periods of time in superconducting structures, which leads to long-range wakefields. Clear understanding of the long-range wakefield effects is a critical element for risk mitigation of future SCRF accelerators such as XFEL at DESY, LCLS-II XFEL, and MaRIE XFEL. We are currently developing numerical tools for simulating long-rangemore » wakefields in SCRF accelerators and plan to experimentally verify the tools by measuring these wakefields at the Fermilab Accelerator Science and Technology (FAST) facility. This paper previews the experimental conditions at the FAST 50 MeV beamline based on the simulation results.« less

  8. Preschool Facilities: Are States Providing Adequate Guidance?

    ERIC Educational Resources Information Center

    Lea, Dennis R.; Polster, Patty Poppe

    2010-01-01

    The preschool facility is a critical element of an effective preschool program. The recent economic downturn in the United States makes it difficult for states and individual school districts to consider developing new preschool programs or enhancing current programs or facilities. Yet many Americans still agree that public investment in preschool…

  9. 36 CFR 1234.10 - What are the facility requirements for all records storage facilities?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... the HVAC systems, fire alarm and fire protection systems. Manual switching between sources of service... elements are protected by a properly installed, properly maintained wet-pipe automatic sprinkler system, as... must provide documentation that the facility has a fire suppression system specifically designed to...

  10. Education Facilities Sector-Specific Plan: An Annex to the Government Facilities Sector-Specific Plan

    ERIC Educational Resources Information Center

    US Department of Homeland Security, 2010

    2010-01-01

    Critical infrastructure and key resources (CIKR) provide the essential services that support basic elements of American society. Compromise of these CIKR could disrupt key government and industry activities, facilities, and systems, producing cascading effects throughout the Nation's economy and society and profoundly affecting the national…

  11. 28 CFR 36.402 - Alterations.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... affect the usability of the building or facility or any part thereof. (1) Alterations include, but are... the usability of the building or facility. (2) If existing elements, spaces, or common areas are...

  12. 28 CFR 36.402 - Alterations.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... affect the usability of the building or facility or any part thereof. (1) Alterations include, but are... the usability of the building or facility. (2) If existing elements, spaces, or common areas are...

  13. 28 CFR 36.402 - Alterations.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... affect the usability of the building or facility or any part thereof. (1) Alterations include, but are... the usability of the building or facility. (2) If existing elements, spaces, or common areas are...

  14. 28 CFR 36.402 - Alterations.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... affect the usability of the building or facility or any part thereof. (1) Alterations include, but are... the usability of the building or facility. (2) If existing elements, spaces, or common areas are...

  15. 28 CFR 36.402 - Alterations.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... affect the usability of the building or facility or any part thereof. (1) Alterations include, but are... the usability of the building or facility. (2) If existing elements, spaces, or common areas are...

  16. 20 CFR 655.310 - Attestations.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... original Form ETA 9029, containing the required attestation elements and the original signature of the... addition, (A) If the facility is a nursing contractor, the special attestation element in paragraph (j) of... nurses only through a nursing contractor, the special attestation element in paragraph (k) of this...

  17. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Han, Bo-Young; Choi, Daewoong; Park, Se Hwan

    Korea Atomic Energy Research Institute (KAERI) have been developing the design and deployment methodology of Laser- Induced Breakdown Spectroscopy (LIBS) instrument for safeguards application within the argon hot cell environment at Advanced spent fuel Conditioning Process Facility (ACPF), where ACPF is a facility being refurbished for the laboratory-scaled demonstration of advanced spent fuel conditioning process. LIBS is an analysis technology used to measure the emission spectra of excited elements in the local plasma of a target material induced by a laser. The spectra measured by LIBS are analyzed to verify the quality and quantity of the specific element in themore » target matrix. Recently LIBS has been recognized as a promising technology for safeguards purposes in terms of several advantages including a simple sample preparation and in-situ analysis capability. In particular, a feasibility study of LIBS to remotely monitor the nuclear material in a high radiation environment has been carried out for supporting the IAEA safeguards implementation. Fiber-Optic LIBS (FO-LIBS) deployment was proposed by Applied Photonics Ltd because the use of fiber optics had benefited applications of LIBS by delivering the laser energy to the target and by collecting the plasma light. The design of FO-LIBS instrument for the measurement of actinides in the spent fuel and high temperature molten salt at ACPF had been developed in cooperation with Applied Photonics Ltd. FO-LIBS has some advantages as followings: the detectable plasma light wavelength range is not limited by the optical properties of the thick lead-glass shield window and the potential risk of laser damage to the lead-glass shield window is not considered. The remote LIBS instrument had been installed at ACPF and then the feasibility study for monitoring actinide elements such as uranium, plutonium, and curium in process materials has been carried out. (authors)« less

  18. Reducing the Risk of Human Space Missions with INTEGRITY

    NASA Technical Reports Server (NTRS)

    Jones, Harry W.; Dillon-Merill, Robin L.; Tri, Terry O.; Henninger, Donald L.

    2003-01-01

    The INTEGRITY Program will design and operate a test bed facility to help prepare for future beyond-LEO missions. The purpose of INTEGRITY is to enable future missions by developing, testing, and demonstrating advanced human space systems. INTEGRITY will also implement and validate advanced management techniques including risk analysis and mitigation. One important way INTEGRITY will help enable future missions is by reducing their risk. A risk analysis of human space missions is important in defining the steps that INTEGRITY should take to mitigate risk. This paper describes how a Probabilistic Risk Assessment (PRA) of human space missions will help support the planning and development of INTEGRITY to maximize its benefits to future missions. PRA is a systematic methodology to decompose the system into subsystems and components, to quantify the failure risk as a function of the design elements and their corresponding probability of failure. PRA provides a quantitative estimate of the probability of failure of the system, including an assessment and display of the degree of uncertainty surrounding the probability. PRA provides a basis for understanding the impacts of decisions that affect safety, reliability, performance, and cost. Risks with both high probability and high impact are identified as top priority. The PRA of human missions beyond Earth orbit will help indicate how the risk of future human space missions can be reduced by integrating and testing systems in INTEGRITY.

  19. Magnetohydrodynamics (MHD) Engineering Test Facility (ETF) 200 MWe power plant. Conceptual Design Engineering Report (CDER). Volume 1: Executive summary

    NASA Astrophysics Data System (ADS)

    1981-09-01

    Main elements of the design are identified and explained, and the rationale behind them was reviewed. Major systems and plant facilities are listed and discussed. Construction cost and schedule estimates are presented, and the engineering issues that should be reexamined are identified. The latest (1980-1981) information from the MHD technology program is integrated with the elements of a conventional steam power electric generating plant.

  20. Magnetohydrodynamics (MHD) Engineering Test Facility (ETF) 200 MWe power plant. Conceptual Design Engineering Report (CDER). Volume 1: Executive summary

    NASA Technical Reports Server (NTRS)

    1981-01-01

    Main elements of the design are identified and explained, and the rationale behind them was reviewed. Major systems and plant facilities are listed and discussed. Construction cost and schedule estimates are presented, and the engineering issues that should be reexamined are identified. The latest (1980-1981) information from the MHD technology program is integrated with the elements of a conventional steam power electric generating plant.

  1. Engineering Evaluation/Cost Analysis (EE/CA) for Decommissioning of TAN-607 Hot Shop Area

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    J. P. Floerke

    Test Area North (TAN) -607, the Technical Support Facility, is located at the north end of the Idaho National Laboratory (INL) Site. U.S. Department of Energy Idaho Operations Office (DOE-ID) is proposing to decommission the northern section of the TAN-607 facility, hereinafter referred to as TAN-607 Hot Shop Area, under a Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) non-time-critical removal action (NTCRA). Despite significant efforts by the United States (U.S.) Department of Energy (DOE) to secure new business, no future mission has been identified for the TAN-607 Hot Shop Area. Its disposition has been agreed to by the Idahomore » State Historical Preservation Office documented in the Memorandum of Agreement signed October 2005 and it is therefore considered a surplus facility. A key element in DOE's strategy for surplus facilities is decommissioning to the maximum extent possible to ensure risk and building footprint reduction and thereby eliminating operations and maintenance cost. In addition, the DOE's 2006 Strategic Plan is ''complete cleanup of the contaminated nuclear weapons manufacturing and testing sites across the United States. DOE is responsible for the risk reduction and cleanup of the environmental legacy of the Nation's nuclear weapons program, one of the largest, most diverse, and technically complex environmental programs in the world. The Department will successfully achieve this strategic goal by ensuring the safety of the DOE employees and U.S. citizens, acquiring the best resources to complete the complex tasks, and managing projects throughout the United States in the most efficient and effective manner.'' TAN-607 is designated as a historical Signature Property by DOE Headquarters Advisory Council on Historic Preservation and, as such, public participation is required to determine the final disposition of the facility. The decommissioning action will place the TAN-607 Hot Shop Area in a final configuration that will be protective of human health and the environment. Decommissioning the TAN-607 Hot Shop Area is consistent with the joint DOE and U.S. Environmental Protection Agency (EPA) Policy on Decommissioning of Department of Energy Facilities Under the Comprehensive Environmental Response, Compensation and Liability Act, which establishes the CERCLA NTCRA process as the preferred approach for decommissioning surplus DOE facilities. Under this policy, a NTCRA may be taken when DOE determines that the action will prevent, minimize, stabilize, or eliminate a risk to human health and/or the environment. When DOE determines that a CERCLA NTCRA is necessary, DOE is authorized to evaluate, select, and implement the removal action that DOE determines is most appropriate to address the potential risk posed by the release or threat of release. This action is taken in accordance with applicable authorities and in conjunction with EPA and the State of Idaho pursuant to Section 5.3 of the Federal Facility Agreement and Consent Order. In keeping with the joint policy, this engineering evaluation/cost analysis (EE/CA) was developed in accordance with CERCLA as amended by the ''Superfund Amendments and Reauthorization Act of 1986'' and in accordance with the ''National Oil and Hazardous Substances Pollution Contingency Plan.'' This EE/CA is consistent with the remedial action objectives (RAOs) of the Final Record of Decision, Test Area North, Operable Unit 1-10 and supports the overall remediation goals established through the Federal Facility Agreement and Consent Order for Waste Area Group 1. Waste Area Group 1 is located at TAN.« less

  2. Nosocomial infections in geriatric long-term-care and rehabilitation facilities: exploration in the development of a risk index for epidemiological surveillance.

    PubMed

    Golliot, F; Astagneau, P; Cassou, B; Okra, N; Rothan-Tondeur, M; Brücker, G

    2001-12-01

    To compute a risk index for nosocomial infection (NI) surveillance in geriatric long-term-care facilities (LTCFs) and rehabilitation facilities. Analysis of data collected during the French national prevalence survey on NIs conducted in 1996. Risk indices were constructed based on the patient case-mix defined according to risk factors for NIs identified in the elderly. 248 geriatric units in 77 hospitals located in northern France. All hospital inpatients on the day of the survey were included. Data from 11,254 patients were recorded. The overall rate of infected patients was 9.9%. Urinary tract, respiratory tract, and skin were the most common infection sites in both rehabilitation facilities and LTCFs. Eleven risk indices, categorizing patients in 3 to 7 levels of increasing NI risk, ranging from 2.7% to 36.2%, were obtained. Indices offered risk adjustment according to NI rate stratification and clinical relevance of risk factors such as indwelling devices, open bedsores, swallowing disorders, sphincter incontinence, lack of mobility, immunodeficiency, or rehabilitation activity. The optimal index should be tailored to the strategy selected for NI surveillance in geriatric facilities in view of available financial and human resources.

  3. 6 CFR 27.205 - Determination that a chemical facility “presents a high level of security risk.”

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 6 Domestic Security 1 2010-01-01 2010-01-01 false Determination that a chemical facility âpresents a high level of security risk.â 27.205 Section 27.205 Domestic Security DEPARTMENT OF HOMELAND SECURITY, OFFICE OF THE SECRETARY CHEMICAL FACILITY ANTI-TERRORISM STANDARDS Chemical Facility Security...

  4. Medical Isotope Production Analyses In KIPT Neutron Source Facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Talamo, Alberto; Gohar, Yousry

    Medical isotope production analyses in Kharkov Institute of Physics and Technology (KIPT) neutron source facility were performed to include the details of the irradiation cassette and the self-shielding effect. An updated detailed model of the facility was used for the analyses. The facility consists of an accelerator-driven system (ADS), which has a subcritical assembly using low-enriched uranium fuel elements with a beryllium-graphite reflector. The beryllium assemblies of the reflector have the same outer geometry as the fuel elements, which permits loading the subcritical assembly with different number of fuel elements without impacting the reflector performance. The subcritical assembly is drivenmore » by an external neutron source generated from the interaction of 100-kW electron beam with a tungsten target. The facility construction was completed at the end of 2015, and it is planned to start the operation during the year of 2016. It is the first ADS in the world, which has a coolant system for removing the generated fission power. Argonne National Laboratory has developed the design concept and performed extensive design analyses for the facility including its utilization for the production of different radioactive medical isotopes. 99Mo is the parent isotope of 99mTc, which is the most commonly used medical radioactive isotope. Detailed analyses were performed to define the optimal sample irradiation location and the generated activity, for several radioactive medical isotopes, as a function of the irradiation time.« less

  5. Engineering directorate technical facilities catalog

    NASA Technical Reports Server (NTRS)

    Maloy, Joseph E.

    1993-01-01

    The Engineering Directorate Technical Facilities Catalog is designed to provide an overview of the technical facilities available within the Engineering Directorate at the National Aeronautics and Space Administration (NASA), Lyndon B. Johnson Space Center (JSC) in Houston, Texas. The combined capabilities of these engineering facilities are essential elements of overall JSC capabilities required to manage and perform major NASA engineering programs. The facilities are grouped in the text by chapter according to the JSC division responsible for operation of the facility. This catalog updates the facility descriptions for the JSC Engineering Directorate Technical Facilities Catalog, JSC 19295 (August 1989), and supersedes the Engineering Directorate, Principle test and Development Facilities, JSC, 19962 (November 1984).

  6. An Application of Business Process Management to Health Care Facilities.

    PubMed

    Hassan, Mohsen M D

    The purpose of this article is to help health care facility managers and personnel identify significant elements of their facilities to address, and steps and actions to follow, when applying business process management to them. The ABPMP (Association of Business Process Management Professionals) life-cycle model of business process management is adopted, and steps from Lean, business process reengineering, and Six Sigma, and actions from operations management are presented to implement it. Managers of health care facilities can find in business process management a more comprehensive approach to improving their facilities than Lean, Six Sigma, business process reengineering, and ad hoc approaches that does not conflict with them because many of their elements can be included under its umbrella. Furthermore, the suggested application of business process management can guide and relieve them from selecting among these approaches, as well as provide them with specific steps and actions that they can follow. This article fills a gap in the literature by presenting a much needed comprehensive application of business process management to health care facilities that has specific steps and actions for implementation.

  7. Developing tourism facilities based on geotourism in Silalahi Village, Geopark Toba Caldera

    NASA Astrophysics Data System (ADS)

    Ginting, Nurlisa; Sasmita, Anggun

    2018-03-01

    Toba Caldera is one of the biggest lakes in Indonesia with supervolcano geology phenomenon, and its result amazing natural resources. It makes Toba Lake become the number one tourism in North Sumatera. However, tourism in Toba Lake is still needed development. Geotourism is one of the concept that suitable for this case. It is because geotourism is a new development tourism concept that focuses on the natural and geological phenomenon. Silalahi Village is one of the areas in Toba Caldera that still needs development, especially in tourism facilities sector. This research aims to investigation the facilities concept based on geotourism in Silalahi Village that would be analyzed by three element of tourism facilities namely, accommodation, support facilities and tourism auxiliary facilities. The method used for this research is mixed methods by distributing 100 questionnaires, observations directly to the area and interviews with three informants related parties interested in tourism, such as local people, government, and academics. The data would be processed and analyzed with techniques of exploration. The result shows that the three elements of tourism facilities are still lacking and needs to improve to increase the economy and tourism in the area.

  8. KSC-01pp0479

    NASA Image and Video Library

    2001-03-13

    Workers in the Spacecraft Assembly and Encapsulation Facility (SAEF 2) reattach the solar panel on the 2001 Mars Odyssey Orbiter in order to conduct illumination testing. Scheduled for launch April 7, 2001, the orbiter contains three science instruments: THEMIS, the Gamma Ray Spectrometer (GRS), and the Mars Radiation Environment Experiment (MARIE). THEMIS will map the mineralogy and morphology of the Martian surface using a high-resolution camera and a thermal infrared imaging spectrometer. The GRS will achieve global mapping of the elemental composition of the surface and determine the abundance of hydrogen in the shallow subsurface. The MARIE will characterize aspects of the near-space radiation environment with regards to the radiation-related risk to human explorers

  9. KSC-01pp0482

    NASA Image and Video Library

    2001-03-13

    In the Spacecraft Assembly and Encapsulation Facility (SAEF 2), workers get ready to open the panels of the solar array on the 2001 Mars Odyssey Orbiter in order to conduct illumination testing. Scheduled for launch April 7, 2001, the orbiter contains three science instruments: THEMIS, the Gamma Ray Spectrometer (GRS), and the Mars Radiation Environment Experiment (MARIE). THEMIS will map the mineralogy and morphology of the Martian surface using a high-resolution camera and a thermal infrared imaging spectrometer. The GRS will achieve global mapping of the elemental composition of the surface and determine the abundance of hydrogen in the shallow subsurface. The MARIE will characterize aspects of the near-space radiation environment with regards to the radiation-related risk to human explorers

  10. KSC-01pp0481

    NASA Image and Video Library

    2001-03-13

    Workers in the Spacecraft Assembly and Encapsulation Facility (SAEF 2) reattach the solar panel on the 2001 Mars Odyssey Orbiter in order to conduct illumination testing. Scheduled for launch April 7, 2001, the orbiter contains three science instruments: THEMIS, the Gamma Ray Spectrometer (GRS), and the Mars Radiation Environment Experiment (MARIE). THEMIS will map the mineralogy and morphology of the Martian surface using a high-resolution camera and a thermal infrared imaging spectrometer. The GRS will achieve global mapping of the elemental composition of the surface and determine the abundance of hydrogen in the shallow subsurface. The MARIE will characterize aspects of the near-space radiation environment with regards to the radiation-related risk to human explorers

  11. KSC-01pp0483

    NASA Image and Video Library

    2001-03-13

    In the Spacecraft Assembly and Encapsulation Facility (SAEF 2), workers stand back as the panels of the solar array on the 2001 Mars Odyssey Orbiter open. The array will undergo illumination testing. Scheduled for launch April 7, 2001, the orbiter contains three science instruments: THEMIS, the Gamma Ray Spectrometer (GRS), and the Mars Radiation Environment Experiment (MARIE). THEMIS will map the mineralogy and morphology of the Martian surface using a high-resolution camera and a thermal infrared imaging spectrometer. The GRS will achieve global mapping of the elemental composition of the surface and determine the abundance of hydrogen in the shallow subsurface. The MARIE will characterize aspects of the near-space radiation environment with regards to the radiation-related risk to human explorers

  12. KSC-01pp0485

    NASA Image and Video Library

    2001-03-13

    A worker in the Spacecraft Assembly and Encapsulation Facility (SAEF 2) checks the underside of the extended solar array panels on the 2001 Mars Odyssey Orbiter. The array will undergo illumination testing. Scheduled for launch April 7, 2001, the orbiter contains three science instruments: THEMIS, the Gamma Ray Spectrometer (GRS), and the Mars Radiation Environment Experiment (MARIE). THEMIS will map the mineralogy and morphology of the Martian surface using a high-resolution camera and a thermal infrared imaging spectrometer. The GRS will achieve global mapping of the elemental composition of the surface and determine the abundance of hydrogen in the shallow subsurface. The MARIE will characterize aspects of the near-space radiation environment with regards to the radiation-related risk to human explorers

  13. Trace element partitioning in ashes from boilers firing pure wood or mixtures of solid waste with respect to fuel composition, chlorine content and temperature.

    PubMed

    Saqib, Naeem; Bäckström, Mattias

    2014-12-01

    Trace element partitioning in solid waste (household waste, industrial waste, waste wood chips and waste mixtures) incineration residues was investigated. Samples of fly ash and bottom ash were collected from six incineration facilities across Sweden including two grate fired and four fluidized bed incinerators, to have a variation in the input fuel composition (from pure biofuel to mixture of waste) and different temperature boiler conditions. As trace element concentrations in the input waste at the same facilities have already been analyzed, the present study focuses on the concentration of trace elements in the waste fuel, their distribution in the incineration residues with respect to chlorine content of waste and combustion temperature. Results indicate that Zn, Cu and Pb are dominating trace elements in the waste fuel. Highly volatile elements mercury and cadmium are mainly found in fly ash in all cases; 2/3 of lead also end up in fly ash while Zn, As and Sb show a large variation in distribution with most of them residing in the fly ash. Lithophilic elements such as copper and chromium are mainly found in bottom ash from grate fired facilities while partition mostly into fly ash from fluidized bed incinerators, especially for plants fuelled by waste wood or ordinary wood chips. There is no specific correlation between input concentration of an element in the waste fuel and fraction partitioned to fly ash. Temperature and chlorine content have significant effects on partitioning characteristics by increasing the formation and vaporization of highly volatile metal chlorides. Zinc and cadmium concentrations in fly ash increase with the incineration temperature. Copyright © 2014 Elsevier Ltd. All rights reserved.

  14. KENNEDY SPACE CENTER, FLA. - In the Space Station Processing Facility, Executive Director of NASDA Koji Yamamoto points to other Space Station elements. Behind him is the Japanese Experiment Module (JEM)/pressurized module. Mr. Yamamoto is at KSC for a welcome ceremony involving the arrival of JEM.

    NASA Image and Video Library

    2003-06-12

    KENNEDY SPACE CENTER, FLA. - In the Space Station Processing Facility, Executive Director of NASDA Koji Yamamoto points to other Space Station elements. Behind him is the Japanese Experiment Module (JEM)/pressurized module. Mr. Yamamoto is at KSC for a welcome ceremony involving the arrival of JEM.

  15. Reducing drinking water supply chemical contamination: risks from underground storage tanks.

    PubMed

    Enander, Richard T; Hanumara, R Choudary; Kobayashi, Hisanori; Gagnon, Ronald N; Park, Eugene; Vallot, Christopher; Genovesi, Richard

    2012-12-01

    Drinking water supplies are at risk of contamination from a variety of physical, chemical, and biological sources. Ranked among these threats are hazardous material releases from leaking or improperly managed underground storage tanks located at municipal, commercial, and industrial facilities. To reduce human health and environmental risks associated with the subsurface storage of hazardous materials, government agencies have taken a variety of legislative and regulatory actions--which date back more than 25 years and include the establishment of rigorous equipment/technology/operational requirements and facility-by-facility inspection and enforcement programs. Given a history of more than 470,000 underground storage tank releases nationwide, the U.S. Environmental Protection Agency continues to report that 7,300 new leaks were found in federal fiscal year 2008, while nearly 103,000 old leaks remain to be cleaned up. In this article, we report on an alternate evidence-based intervention approach for reducing potential releases from the storage of petroleum products (gasoline, diesel, kerosene, heating/fuel oil, and waste oil) in underground tanks at commercial facilities located in Rhode Island. The objective of this study was to evaluate whether a new regulatory model can be used as a cost-effective alternative to traditional facility-by-facility inspection and enforcement programs for underground storage tanks. We conclude that the alternative model, using an emphasis on technical assistance tools, can produce measurable improvements in compliance performance, is a cost-effective adjunct to traditional facility-by-facility inspection and enforcement programs, and has the potential to allow regulatory agencies to decrease their frequency of inspections among low risk facilities without sacrificing compliance performance or increasing public health risks. © 2012 Society for Risk Analysis.

  16. Centrifuge Facility Conceptual System Study. Volume 1: Facility overview and habitats

    NASA Technical Reports Server (NTRS)

    Synnestvedt, Robert (Editor)

    1990-01-01

    The results are presented for a NASA Phase 1 study conducted from mid 1987 through mid 1989 at Ames Research Center. The Centrifuge Facility is the major element of the biological research facility for the implementation of NASA's Life Science Research Program on Space Station Freedom using non-human specimens (such as small primates, rodents, plants, insects, cell tissues). Five systems are described which comprise the Facility: habitats, holding units, centrifuge, glovebox, and service unit. Volume 1 presents a facility overview and describes the habitats - modular units which house living specimens.

  17. 42 CFR 136.105 - Project elements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Project elements. 136.105 Section 136.105 Public... Facilities and Services § 136.105 Project elements. A project supported under this subpart must: (a) Have sufficient, adequately trained staff in relation to the scope of the project. (b) Maintain a mechanism for...

  18. 42 CFR 136.105 - Project elements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 1 2013-10-01 2013-10-01 false Project elements. 136.105 Section 136.105 Public... Facilities and Services § 136.105 Project elements. A project supported under this subpart must: (a) Have sufficient, adequately trained staff in relation to the scope of the project. (b) Maintain a mechanism for...

  19. 42 CFR 136.105 - Project elements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 1 2014-10-01 2014-10-01 false Project elements. 136.105 Section 136.105 Public... Facilities and Services § 136.105 Project elements. A project supported under this subpart must: (a) Have sufficient, adequately trained staff in relation to the scope of the project. (b) Maintain a mechanism for...

  20. 42 CFR 136.105 - Project elements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 1 2012-10-01 2012-10-01 false Project elements. 136.105 Section 136.105 Public... Facilities and Services § 136.105 Project elements. A project supported under this subpart must: (a) Have sufficient, adequately trained staff in relation to the scope of the project. (b) Maintain a mechanism for...

  1. 42 CFR 136.105 - Project elements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Project elements. 136.105 Section 136.105 Public... Facilities and Services § 136.105 Project elements. A project supported under this subpart must: (a) Have sufficient, adequately trained staff in relation to the scope of the project. (b) Maintain a mechanism for...

  2. Analysis of local acceptance of a radioactive waste disposal facility.

    PubMed

    Chung, Ji Bum; Kim, Hong-Kew; Rho, Sam Kew

    2008-08-01

    Like many other countries in the world, Korea has struggled to site a facility for radioactive waste for almost 30 years because of the strong opposition from local residents. Finally, in 2005, Gyeongju was established as the first Korean site for a radioactive waste facility. The objectives of this research are to verify Gyeongju citizens' average level of risk perception of a radioactive waste disposal facility as compared to other risks, and to explore the best model for predicting respondents' acceptance level using variables related to cost-benefit, risk perception, and political process. For this purpose, a survey is conducted among Gyeongju residents, the results of which are as follows. First, the local residents' risk perception of an accident in a radioactive waste disposal facility is ranked seventh among a total of 13 risks, which implies that nuclear-related risk is not perceived very highly by Gyeongju residents; however, its characteristics are still somewhat negative. Second, the comparative regression analyses show that the cost-benefit and political process models are more suitable for explaining the respondents' level of acceptance than the risk perception model. This may be the result of the current economic depression in Gyeongju, residents' familiarity with the nuclear industry, or cultural characteristics of risk tolerance.

  3. KSC ground operations planning for Space Station

    NASA Technical Reports Server (NTRS)

    Lyon, J. R.; Revesz, W., Jr.

    1993-01-01

    At the Kennedy Space Center (KSC) in Florida, processing facilities are being built and activated to support the processing, checkout, and launch of Space Station elements. The generic capability of these facilities will be utilized to support resupply missions for payloads, life support services, and propellants for the 30-year life of the program. Special Ground Support Equipment (GSE) is being designed for Space Station hardware special handling requirements, and a Test, Checkout, and Monitoring System (TCMS) is under development to verify that the flight elements are ready for launch. The facilities and equipment used at KSC, along with the testing required to accomplish the mission, are described in detail to provide an understanding of the complexity of operations at the launch site. Assessments of hardware processing flows through KSC are being conducted to minimize the processing flow times for each hardware element. Baseline operations plans and the changes made to improve operations and reduce costs are described, recognizing that efficient ground operations are a major key to success of the Space Station.

  4. Neutral atoms facility for space sensors characterization and BepiColombo/ELENA development instrument's progresses.

    NASA Astrophysics Data System (ADS)

    de Angelis, E.; di Lellis, A. M.; Orsini, S.; Zanza, V.; Maggi, M.; Vertolli, N.; D'Amicis, R.; Tilia, B.; Sibio, A.

    2003-04-01

    An Energetic Neutral Atoms facility to test and calibrate Neutral Atoms Analyzers has been developed in the Scientific Technical Unit of Fusion at the ENEA Research Center in Frascati (Rome-Italy). In the last years a collaboration with IFSI (Interplanetary Space and Physics Institute, CNR-Rome-Italy) has allowed to use this facility for space sensors and for characterization of crucial instruments elements. The ENA beam is realized with an ion source and a neutralization cell, and allows to test any instrument in the energy range 300eV-110keV with the available masses of Hydrogen, Deuterium or Helium. At the moment, the critical elements of ELENA (Emitted Low Energy Neutral Atoms) instrument proposed for BepiColombo ESA cornerstone mission to Mercury is under development testing. The facility, its potentiality and the instrument characterization progresses are presented.

  5. Harbors.

    DTIC Science & Technology

    1981-07-01

    CONTRACT OR GRANT NUMBER(e) Naval Facilities Engineering Command 200 Stovall Street r Alexandria, VA 22332 (Code 0453) s. PERFORMING ORGANIZATION NAME...AND ADDRESS 10. PROGRAM ELEMENT. PROJECT. TASK • Naval Facilities Engineering Command AREA & WORK UNIT NUMBERS < 200 Stovall Street Engineering and...Design Alexandria, VA 22332 It. CONTROLLING OFFICE NAME AND ADDRESS 12. REPORT DATE ~ Naval Facilities Engineering Command (Code10432) July 1981 200

  6. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hamilton, T F

    Rongelap Atoll experienced close-in ''local fallout'' from nuclear weapons tests conducted by the United States (1946-58) in the northern Marshall Islands. Most of the radiation dose delivered to Rongelap Island residents during the 1950s was from radioactive elements that quickly decayed into non-radioactive elements. Since 1985, the Lawrence Livermore National Laboratory (LLNL) has continued to provide monitoring of radioactive elements from bomb testing in the terrestrial and marine environment of Rongelap Atoll. The only remaining radioactive elements of environmental importance at the atoll are radioactive cesium (cesium-137), radioactive strontium (strontium-90), different types (isotopes) of plutonium, and americium (americium-241). Cesium- 137more » and strontium-90 dissolve in seawater and are continually flushed out of the lagoon into the open ocean. The small amount of residual radioactivity from nuclear weapons tests remaining in the lagoon does not concentrate through the marine food chain. Elevated levels of cesium-137 and strontium-90 are still present in island soils and pose a potential health risk if certain types of local plants and coconut crabs are eaten in large quantities. Cesium-137 is taken up from the soil into plants and edible food products, and may end up in the body of people living on the islands and consuming local food. The presence of cesium-137 in the human body can be detected using a device called a whole body counter. A person relaxes in a chair for a few minutes while counts or measurements are taken using a detector a few inches away from the body. The whole body counting program on Rongelap Island was established in 1999 under a cooperative agreement between the Rongelap Atoll Local Government (RALG), the Republic of the Marshall Islands and the U.S. Department of Energy (DOE). Local technicians from Rongelap continue to operate the facility under supervision of scientists from LLNL. The facility permits resettlement workers living on Rongelap Island to check the amount of cesium-137 in their bodies. The amount of cesium-137 detected in resettlement workers living on Rongelap Island over the past three years is well below the level of radiation exposure considered safe by the Nuclear Claims Tribunal. Returning residents and visitors to Rongelap will also be able to receive a whole body count free of charge to check the level of cesium in their bodies. There is also a very low health risk from exposure to external sources of radiation from visiting or walking around any of the islands on the atoll.« less

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    MATALUCCI,RUDOLPH V.; O'CONNOR,SHARON

    The mission of the Architectural Surety{trademark} program at Sandia National Laboratories is to assure the performance of buildings, facilities, and other infrastructure systems under normal, abnormal, and malevolent threat conditions. Through educational outreach efforts in the classroom, at conferences, and presentations such as this one, public and professional awareness of the need to defuse and mitigate such threats is increased. Buildings, airports, utilities, and other kinds of infrastructure deteriorate over time, as evidenced most dramatically by the crumbling cities and aging buildings, bridges, and other facility systems. Natural disasters such as tornadoes, earthquakes, hurricanes, and flooding also stress the materialsmore » and structural elements of the built environment. In addition, criminals, vandals, and terrorists attack federal buildings, dams, bridges, tunnels, and other public and private facilities. Engineers and architects are beginning to systematically consider these threats during the design, construction, and retrofit phases of buildings and infrastructures and are recommending advanced research in new materials and techniques. Existing building codes and standards do not adequately address nor protect the infrastructure or the public from many of these emerging threats. The activities in Sandia National Laboratories' Architectural Surety{trademark} efforts take a risk management approach to enhancing the safety, security, and reliability of the constructed environment. The technologies and techniques developed during Sandia's 50 years as the nation's lead laboratory for nuclear weapons surety are now being applied to assessing and reducing the vulnerability of dams, to enhancing the safety and security of staff in foreign embassies, and assuring the reliability of other federal facilities. High consequence surety engineering and design brings together technological advancements, new material requirements, systems integration, and risk management to improve the safety, security, and reliability of the as-built environment. The thrust of this paper is the role that new materials can play in protecting the infrastructure. Retrofits of existing buildings, innovative approaches to the design and construction of new facilities, and the mitigation of consequences in the event of an unpreventable disaster are some of the areas that new construction materials can benefit the Architectural Surety{trademark} of the constructed environment.« less

  8. Cancer risks near nuclear facilities: the importance of research design and explicit study hypotheses.

    PubMed

    Wing, Steve; Richardson, David B; Hoffmann, Wolfgang

    2011-04-01

    In April 2010, the U.S. Nuclear Regulatory Commission asked the National Academy of Sciences to update a 1990 study of cancer risks near nuclear facilities. Prior research on this topic has suffered from problems in hypothesis formulation and research design. We review epidemiologic principles used in studies of generic exposure-response associations and in studies of specific sources of exposure. We then describe logical problems with assumptions, formation of testable hypotheses, and interpretation of evidence in previous research on cancer risks near nuclear facilities. Advancement of knowledge about cancer risks near nuclear facilities depends on testing specific hypotheses grounded in physical and biological mechanisms of exposure and susceptibility while considering sample size and ability to adequately quantify exposure, ascertain cancer cases, and evaluate plausible confounders. Next steps in advancing knowledge about cancer risks near nuclear facilities require studies of childhood cancer incidence, focus on in utero and early childhood exposures, use of specific geographic information, and consideration of pathways for transport and uptake of radionuclides. Studies of cancer mortality among adults, cancers with long latencies, large geographic zones, and populations that reside at large distances from nuclear facilities are better suited for public relations than for scientific purposes.

  9. Numerical Simulations of Instabilities in Single-Hole Office Elements

    NASA Technical Reports Server (NTRS)

    Ahuja, Vineet; Hosangadi, Ashvin; Hitt, Matthew A.; Lineberry, David M.

    2013-01-01

    An orifice element is commonly used in liquid rocket engine test facilities either as a flow metering device, a damper for acoustic resonance or to provide a large reduction in pressure over a very small distance in the piping system. While the orifice as a device is largely effective in stepping down pressure, it is also susceptible to a wake-vortex type instability that generates pressure fluctuations that propagate downstream and interact with other elements of the test facility resulting in structural vibrations. Furthermore in piping systems an unstable feedback loop can exist between the vortex shedding and acoustic perturbations from upstream components resulting in an amplification of the modes convecting downstream. Such was the case in several tests conducted at NASA as well as in the Ariane 5 strap-on P230 engine in a static firing test where pressure oscillations of 0.5% resulted in 5% thrust oscillations. Exacerbating the situation in cryogenic test facilities, is the possibility of the formation of vapor clouds when the pressure in the wake falls below the vapor pressure leading to a cavitation instability that has a lower frequency than the primary wake-vortex instability. The cavitation instability has the potential for high amplitude fluctuations that can cause catastrophic damage in the facility. In this paper high-fidelity multi-phase numerical simulations of an orifice element are used to characterize the different instabilities, understand the dominant instability mechanisms and identify the tonal content of the instabilities.

  10. Strategic Defense Initiative Demonstration/Validation Program Environmental Assessment. Space-Based Surveillance and Tracking System (SSTS),

    DTIC Science & Technology

    1987-08-01

    take place in both contractor and government facilities. The on-orbit evaluation could utilize modified launch facilities depending on the launch...technological issues : o Telescope Optics: Verify that the distortions associated vith large optical elements satisfy detection and tracking requirements; verify...Validation program vould be car- ried out at contractor facilities that 1’ave not been identified and at six government facilities (Arnold Engineering

  11. James Webb Space Telescope (JWST) Integrated Science Instruments Module (ISIM) Cryo-Vacuum (CV) Test Campaign Summary

    NASA Technical Reports Server (NTRS)

    Yew, Calinda; Whitehouse, Paul; Lui, Yan; Banks, Kimberly

    2016-01-01

    JWST Integrated Science Instruments Module (ISIM) has completed its system-level testing program at the NASA Goddard Space Flight Center (GSFC). In March 2016, ISIM was successfully delivered for integration with the Optical Telescope Element (OTE) after the successful verification of the system through a series of three cryo-vacuum (CV) tests. The first test served as a risk reduction test; the second test provided the initial verification of the fully-integrated flight instruments; and the third test verified the system in its final flight configuration. The complexity of the mission has generated challenging requirements that demand highly reliable system performance and capabilities from the Space Environment Simulator (SES) vacuum chamber. As JWST progressed through its CV testing campaign, deficiencies in the test configuration and support equipment were uncovered from one test to the next. Subsequent upgrades and modifications were implemented to improve the facility support capabilities required to achieve test requirements. This paper: (1) provides an overview of the integrated mechanical and thermal facility systems required to achieve the objectives of JWST ISIM testing, (2) compares the overall facility performance and instrumentation results from the three ISIM CV tests, and (3) summarizes lessons learned from the ISIM testing campaign.

  12. An Architecture for Intelligent Systems Based on Smart Sensors

    NASA Technical Reports Server (NTRS)

    Schmalzel, John; Figueroa, Fernando; Morris, Jon; Mandayam, Shreekanth; Polikar, Robi

    2004-01-01

    Based on requirements for a next-generation rocket test facility, elements of a prototype Intelligent Rocket Test Facility (IRTF) have been implemented. A key component is distributed smart sensor elements integrated using a knowledgeware environment. One of the specific goals is to imbue sensors with the intelligence needed to perform self diagnosis of health and to participate in a hierarchy of health determination at sensor, process, and system levels. The preliminary results provide the basis for future advanced development and validation using rocket test stand facilities at Stennis Space Center (SSC). We have identified issues important to further development of health-enabled networks, which should be of interest to others working with smart sensors and intelligent health management systems.

  13. Magnetohydrodynamics (MHD) Engineering Test Facility (ETF) 200 MWe power plant. Conceptual Design Engineering Report (CDER). Volume 4: Supplementary engineering data

    NASA Astrophysics Data System (ADS)

    1981-09-01

    The reference conceptual design of the Magnetohydrodynamic Engineering Test Facility (ETF), a prototype 200 MWe coal-fired electric generating plant designed to demonstrate the commercial feasibility of open cycle MHD is summarized. Main elements of the design are identified and explained, and the rationale behind them is reviewed. Major systems and plant facilities are listed and discussed. Construction cost and schedule estimates, and identification of engineering issues that should be reexamined are also given. The latest (1980-1981) information from the MHD technology program are integrated with the elements of a conventional steam power electric generating plant. Supplementary Engineering Data (Issues, Background, Performance Assurance Plan, Design Details, System Design Descriptions and Related Drawings) is presented.

  14. Magnetohydrodynamics (MHD) Engineering Test Facility (ETF) 200 MWe power plant. Conceptual Design Engineering Report (CDER). Volume 4: Supplementary engineering data

    NASA Technical Reports Server (NTRS)

    1981-01-01

    The reference conceptual design of the Magnetohydrodynamic Engineering Test Facility (ETF), a prototype 200 MWe coal-fired electric generating plant designed to demonstrate the commercial feasibility of open cycle MHD is summarized. Main elements of the design are identified and explained, and the rationale behind them is reviewed. Major systems and plant facilities are listed and discussed. Construction cost and schedule estimates, and identification of engineering issues that should be reexamined are also given. The latest (1980-1981) information from the MHD technology program are integrated with the elements of a conventional steam power electric generating plant. Supplementary Engineering Data (Issues, Background, Performance Assurance Plan, Design Details, System Design Descriptions and Related Drawings) is presented.

  15. Models and finite element approximations for interacting nanosized piezoelectric bodies and acoustic medium

    NASA Astrophysics Data System (ADS)

    Nasedkin, A. V.

    2017-01-01

    This research presents the new size-dependent models of piezoelectric materials oriented to finite element applications. The proposed models include the facilities of taking into account different mechanisms of damping for mechanical and electric fields. The coupled models also incorporate the equations of the theory of acoustics for viscous fluids. In particular cases, these models permit to use the mode superposition method with full separation of the finite element systems into independent equations for the independent modes for transient and harmonic problems. The main boundary conditions were supplemented with the facilities of taking into account the coupled surface effects, allowing to explore the nanoscale piezoelectric materials in the framework of theories of continuous media with surface stresses and their generalizations. For the considered problems we have implemented the finite element technologies and various numerical algorithms to maintain a symmetrical structure of the finite element quasi-definite matrices (matrix structure for the problems with a saddle point).

  16. Initial Operation and Shakedown of the Nuclear Thermal Rocket Element Environmental Simulator (NTREES)

    NASA Technical Reports Server (NTRS)

    Emrich, William J., Jr.

    2014-01-01

    To support the on-going nuclear thermal propulsion effort, a state-of-the-art non nuclear experimental test setup has been constructed to evaluate the performance characteristics of candidate fuel element materials and geometries in representative environments. The facility to perform this testing is referred to as the Nuclear Thermal Rocket Element Environment Simulator (NTREES). This device can simulate the environmental conditions (minus the radiation) to which nuclear rocket fuel components will be subjected during reactor operation. Prototypical fuel elements mounted in the simulator are inductively heated in such a manner so as to accurately reproduce the temperatures and heat fluxes which would normally occur as a result of nuclear fission in addition to being exposed to flowing hydrogen. Recent upgrades to NTREES now allow power levels 24 times greater than those achievable in the previous facility configuration. This higher power operation will allow near prototypical power densities and flows to finally be achieved in most prototypical fuel elements.

  17. Practice variation in the structure of stroke rehabilitation in four rehabilitation centres in the Netherlands.

    PubMed

    Groeneveld, Iris F; Meesters, Jorit J L; Arwert, Henk J; Roux-Otter, Nienke; Ribbers, Gerard M; van Bennekom, Coen A M; Goossens, Paulien H; Vliet Vlieland, Thea P M

    2016-03-01

    To describe practice variation in the structure of stroke rehabilitation in 4 specialized multidisciplinary rehabilitation centres in the Netherlands. A multidisciplinary expert group formulated a set of 23 elements concerning the structure of inpatient and outpatient stroke rehabilitation, categorized into 4 domains: admission-related (n = 7), treatment-related (n = 10), client involvement-related (n = 2), and facilities-related (n = 4). In a cross-sectional study in 4 rehabilitation centres data on the presence and content of these elements were abstracted from treatment programmes and protocols. In a structured expert meeting consensus was reached on the presence of practice variation per element. Practice variation was observed in 22 of the 23 structure elements. The element "strategies for patient involvement" appeared similar in all rehabilitation centres, whereas differences were found in the elements regarding admission, exclusion and discharge criteria, patient subgroups, care pathways, team meetings, clinical assessments, maximum time to admission, aftercare and return to work modules, health professionals, treatment facilities, and care-giver involvement. Practice variation was found in a wide range of aspects of the structure of stroke rehabilitation.

  18. 75 FR 81337 - Interim Final Regulation Deferring the Reporting Date for Certain Data Elements Required Under...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-27

    ... Meat processing facilities. 311411 Frozen fruit, juice, and vegetable manufacturing facilities. 311421... volume conversion factor. Y 98.256(m)(3) Only total quantity of crude oil plus the quantity of...

  19. Chemical facility vulnerability assessment project.

    PubMed

    Jaeger, Calvin D

    2003-11-14

    Sandia National Laboratories, under the direction of the Office of Science and Technology, National Institute of Justice, conducted the chemical facility vulnerability assessment (CFVA) project. The primary objective of this project was to develop, test and validate a vulnerability assessment methodology (VAM) for determining the security of chemical facilities against terrorist or criminal attacks (VAM-CF). The project also included a report to the Department of Justice for Congress that in addition to describing the VAM-CF also addressed general observations related to security practices, threats and risks at chemical facilities and chemical transport. In the development of the VAM-CF Sandia leveraged the experience gained from the use and development of VAs in other areas and the input from the chemical industry and Federal agencies. The VAM-CF is a systematic, risk-based approach where risk is a function of the severity of consequences of an undesired event, the attack potential, and the likelihood of adversary success in causing the undesired event. For the purpose of the VAM-CF analyses Risk is a function of S, L(A), and L(AS), where S is the severity of consequence of an event, L(A) is the attack potential and L(AS) likelihood of adversary success in causing a catastrophic event. The VAM-CF consists of 13 basic steps. It involves an initial screening step, which helps to identify and prioritize facilities for further analysis. This step is similar to the prioritization approach developed by the American Chemistry Council (ACC). Other steps help to determine the components of the risk equation and ultimately the risk. The VAM-CF process involves identifying the hazardous chemicals and processes at a chemical facility. It helps chemical facilities to focus their attention on the most critical areas. The VAM-CF is not a quantitative analysis but, rather, compares relative security risks. If the risks are deemed too high, recommendations are developed for measures to reduce the risk. This paper will briefly discuss the CFVA project and VAM-CF process.

  20. Aerosol Emission Monitoring and Assessment of Potential Exposure to Multi-walled Carbon Nanotubes in the Manufacture of Polymer Nanocomposites

    PubMed Central

    Thompson, Drew; Chen, Sheng-Chieh; Wang, Jing; Pui, David Y.H.

    2015-01-01

    Recent animal studies have shown that carbon nanotubes (CNTs) may pose a significant health risk to those exposed in the workplace. To further understand this potential risk, effort must be taken to measure the occupational exposure to CNTs. Results from an assessment of potential exposure to multi-walled carbon nanotubes (MWCNTs) conducted at an industrial facility where polymer nanocomposites were manufactured by an extrusion process are presented. Exposure to MWCNTs was quantified by the thermal-optical analysis for elemental carbon (EC) of respirable dust collected by personal sampling. All personal respirable samples collected (n = 8) had estimated 8-h time weighted average (TWA) EC concentrations below the limit of detection for the analysis which was about one-half of the recommended exposure limit for CNTs, 1 µg EC/m3 as an 8-h TWA respirable mass concentration. Potential exposure sources were identified and characterized by direct-reading instruments and area sampling. Area samples analyzed for EC yielded quantifiable mass concentrations inside an enclosure where unbound MWCNTs were handled and near a pelletizer where nanocomposite was cut, while those analyzed by electron microscopy detected the presence of MWCNTs at six locations throughout the facility. Through size selective area sampling it was identified that the airborne MWCNTs present in the workplace were in the form of large agglomerates. This was confirmed by electron microscopy where most of the MWCNT structures observed were in the form of micrometer-sized ropey agglomerates. However, a small fraction of single, free MWCNTs was also observed. It was found that the high number concentrations of nanoparticles, ~200000 particles/cm3, present in the manufacturing facility were likely attributable to polymer fumes produced in the extrusion process. PMID:26209597

  1. Summary of Plutonium-238 Production Alternatives Analysis Final Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    James Werner; Wade E. Bickford; David B. Lord

    The Team implemented a two-phase evaluation process. During the first phase, a wide variety of past and new candidate facilities and processing methods were assessed against the criteria established by DOE for this assessment. Any system or system element selected for consideration as an alternative within the project to reestablish domestic production of Pu-238 must meet the following minimum criteria: Any required source material must be readily available in the United States, without requiring the development of reprocessing technologies or investments in systems to separate material from identified sources. It must be cost, schedule, and risk competitive with existing baselinemore » technology. Any identified facilities required to support the concept must be available to the program for the entire project life cycle (notionally 35 years, unless the concept is so novel as to require a shorter duration). It must present a solution that can generate at least 1.5 Kg of Pu-238 oxide per year, for at least 35 years. It must present a low-risk, near-term solution to the National Aeronautics and Space Administration’s urgent mission need. DOE has implemented this requirement by eliminating from project consideration any alternative with key technologies at less than Technology Readiness Level 5. The Team evaluated the options meeting these criteria using a more detailed assessment of the reasonable facility variations and compared them to the preferred option, which consists of target irradiation at the Advanced Test Reactor (ATR) and the High Flux Isotope Reactor (HFIR), target fabrication and chemical separations processing at the ORNL Radiochemical Engineering Development Center, and neptunium 237 storage at the Materials and Fuels Complex at INL. This preferred option is consistent with the Records of Decision from the earlier National Environmental Policy Act (NEPA) documentation« less

  2. Site specific risk assessment of an energy-from-waste thermal treatment facility in Durham Region, Ontario, Canada. Part A: Human health risk assessment.

    PubMed

    Ollson, Christopher A; Knopper, Loren D; Whitfield Aslund, Melissa L; Jayasinghe, Ruwan

    2014-01-01

    The regions of Durham and York in Ontario, Canada have partnered to construct an energy-from-waste thermal treatment facility as part of a long term strategy for the management of their municipal solid waste. This paper presents the results of a comprehensive human health risk assessment for this facility. This assessment was based on extensive sampling of baseline environmental conditions (e.g., collection and analysis of air, soil, water, and biota samples) as well as detailed site specific modeling to predict facility-related emissions of 87 identified contaminants of potential concern. Emissions were estimated for both the approved initial operating design capacity of the facility (140,000 tonnes per year) and for the maximum design capacity (400,000 tonnes per year). For the 140,000 tonnes per year scenario, this assessment indicated that facility-related emissions are unlikely to cause adverse health risks to local residents, farmers, or other receptors (e.g., recreational users). For the 400,000 tonnes per year scenarios, slightly elevated risks were noted with respect to inhalation (hydrogen chloride) and infant consumption of breast milk (dioxins and furans), but only during predicted 'upset conditions' (i.e. facility start-up, shutdown, and loss of air pollution control) that represent unusual and/or transient occurrences. However, current provincial regulations require that additional environmental screening would be mandatory prior to expansion of the facility beyond the initial approved capacity (140,000 tonnes per year). Therefore, the potential risks due to upset conditions for the 400,000 tonnes per year scenario should be more closely investigated if future expansion is pursued. © 2013.

  3. Risk element immobilization/stabilization potential of fungal-transformed dry olive residue and arbuscular mycorrhizal fungi application in contaminated soils.

    PubMed

    García-Sánchez, Mercedes; Stejskalová, Tereza; García-Romera, Inmaculada; Száková, Jiřina; Tlustoš, Pavel

    2017-10-01

    The use of biotransformed dry olive residue (DOR) as organic soil amendment has recently been proposed due to its high contents of stabilized organic matter and nutrients. The potential of biotransformed DOR to immobilize risk elements in contaminated soils might qualify DOR as a potential risk element stabilization agent for in situ soil reclamation practices. In this experiment, the mobility of risk elements in response to Penicillium chrysogenum-10-transformed DOR, Funalia floccosa-transformed DOR, Bjerkandera adusta-transformed DOR, and Chondrostereum purpureum-transformed DOR as well as arbuscular mycorrhizal fungi (AMF), Funneliformis mosseae, inoculation was investigated. We evaluated the effect of these treatments on risk element uptake by wheat (Triticum aestivum L.) plants in a pot experiment with Cd, Pb, and Zn contaminated soil. The results showed a significant impact of the combined treatment (biotransformed DOR and AMF inoculation) on wheat plant growth and element mobility. The mobile proportions of elements in the treated soils were related to soil pH; with increasing pH levels, Cd, Cu, Fe, Mn, P, Pb, and Zn mobility decreased significantly (r values between -0.36 and -0.46), while Ca and Mg mobility increased (r = 0.63, and r = 0.51, respectively). The application of biotransformed DOR decreased risk element levels (Cd, Zn), and nutrient concentrations (Ca, Cu, Fe, Mg, Mn) in the aboveground biomass, where the elements were retained in the roots. Thus, biotransformed DOR in combination with AMF resulted in a higher capacity of wheat plants to grow under detrimental conditions, being able to accumulate high amounts of risk elements in the roots. However, risk element reduction was insufficient for safe crop production in the extremely contaminated soil. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. 40 CFR 61.121 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS National Emission Standards for Radionuclide Emissions From Elemental Phosphorus Plants § 61.121 Definitions. (a) Elemental phosphorus plant or plant means any facility...

  5. Site specific risk assessment of an energy-from-waste/thermal treatment facility in Durham Region, Ontario, Canada. Part B: Ecological risk assessment.

    PubMed

    Ollson, Christopher A; Whitfield Aslund, Melissa L; Knopper, Loren D; Dan, Tereza

    2014-01-01

    The regions of Durham and York in Ontario, Canada have partnered to construct an energy-from-waste (EFW) thermal treatment facility as part of a long term strategy for the management of their municipal solid waste. In this paper we present the results of a comprehensive ecological risk assessment (ERA) for this planned facility, based on baseline sampling and site specific modeling to predict facility-related emissions, which was subsequently accepted by regulatory authorities. Emissions were estimated for both the approved initial operating design capacity of the facility (140,000 tonnes per year) and the maximum design capacity (400,000 tonnes per year). In general, calculated ecological hazard quotients (EHQs) and screening ratios (SRs) for receptors did not exceed the benchmark value (1.0). The only exceedances noted were generally due to existing baseline media concentrations, which did not differ from those expected for similar unimpacted sites in Ontario. This suggests that these exceedances reflect conservative assumptions applied in the risk assessment rather than actual potential risk. However, under predicted upset conditions at 400,000 tonnes per year (i.e., facility start-up, shutdown, and loss of air pollution control), a potential unacceptable risk was estimated for freshwater receptors with respect to benzo(g,h,i)perylene (SR=1.1), which could not be attributed to baseline conditions. Although this slight exceedance reflects a conservative worst-case scenario (upset conditions coinciding with worst-case meteorological conditions), further investigation of potential ecological risk should be performed if this facility is expanded to the maximum operating capacity in the future. © 2013.

  6. Facilities Information Management: A Guide for State and Local Education Agencies. NCES 2003-400

    ERIC Educational Resources Information Center

    National Center for Education Statistics (ED), Washington, DC.

    This Guide has been developed to provide a framework for decision makers, school facility managers, and the public to identify a basic set of school facilities data elements, including definitions that will meet their information needs. Chapter 1 describes the purpose, scope, and intended audience for this guide. Chapter 2 describes how to use the…

  7. Complementary Microorganisms in Highly Corrosive Biofilms from an Offshore Oil Production Facility.

    PubMed

    Vigneron, Adrien; Alsop, Eric B; Chambers, Brian; Lomans, Bartholomeus P; Head, Ian M; Tsesmetzis, Nicolas

    2016-04-01

    Offshore oil production facilities are frequently victims of internal piping corrosion, potentially leading to human and environmental risks and significant economic losses. Microbially influenced corrosion (MIC) is believed to be an important factor in this major problem for the petroleum industry. However, knowledge of the microbial communities and metabolic processes leading to corrosion is still limited. Therefore, the microbial communities from three anaerobic biofilms recovered from the inside of a steel pipe exhibiting high corrosion rates, iron oxide deposits, and substantial amounts of sulfur, which are characteristic of MIC, were analyzed in detail. Bacterial and archaeal community structures were investigated by automated ribosomal intergenic spacer analysis, multigenic (16S rRNA and functional genes) high-throughput Illumina MiSeq sequencing, and quantitative PCR analysis. The microbial community analysis indicated that bacteria, particularly Desulfovibrio species, dominated the biofilm microbial communities. However, other bacteria, such as Pelobacter, Pseudomonas, and Geotoga, as well as various methanogenic archaea, previously detected in oil facilities were also detected. The microbial taxa and functional genes identified suggested that the biofilm communities harbored the potential for a number of different but complementary metabolic processes and that MIC in oil facilities likely involves a range of microbial metabolisms such as sulfate, iron, and elemental sulfur reduction. Furthermore, extreme corrosion leading to leakage and exposure of the biofilms to the external environment modify the microbial community structure by promoting the growth of aerobic hydrocarbon-degrading organisms. Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  8. Complementary Microorganisms in Highly Corrosive Biofilms from an Offshore Oil Production Facility

    PubMed Central

    Alsop, Eric B.; Chambers, Brian; Lomans, Bartholomeus P.; Head, Ian M.; Tsesmetzis, Nicolas

    2016-01-01

    Offshore oil production facilities are frequently victims of internal piping corrosion, potentially leading to human and environmental risks and significant economic losses. Microbially influenced corrosion (MIC) is believed to be an important factor in this major problem for the petroleum industry. However, knowledge of the microbial communities and metabolic processes leading to corrosion is still limited. Therefore, the microbial communities from three anaerobic biofilms recovered from the inside of a steel pipe exhibiting high corrosion rates, iron oxide deposits, and substantial amounts of sulfur, which are characteristic of MIC, were analyzed in detail. Bacterial and archaeal community structures were investigated by automated ribosomal intergenic spacer analysis, multigenic (16S rRNA and functional genes) high-throughput Illumina MiSeq sequencing, and quantitative PCR analysis. The microbial community analysis indicated that bacteria, particularly Desulfovibrio species, dominated the biofilm microbial communities. However, other bacteria, such as Pelobacter, Pseudomonas, and Geotoga, as well as various methanogenic archaea, previously detected in oil facilities were also detected. The microbial taxa and functional genes identified suggested that the biofilm communities harbored the potential for a number of different but complementary metabolic processes and that MIC in oil facilities likely involves a range of microbial metabolisms such as sulfate, iron, and elemental sulfur reduction. Furthermore, extreme corrosion leading to leakage and exposure of the biofilms to the external environment modify the microbial community structure by promoting the growth of aerobic hydrocarbon-degrading organisms. PMID:26896143

  9. Fifth anniversary of the first element of the International Spac

    NASA Image and Video Library

    2003-12-03

    Members of the media (at left) were invited to commemorate the fifth anniversary of the launch of the first element of the International Space Station by touring the Space Station Processing Facility (SSPF) at KSC. Giving an overview of Space Station processing are, at right, David Bethay (white shirt), Boeing/ISS Florida Operations; Charlie Precourt, deputy manager of the International Space Station Program; and Tip Talone, director of Space Station and Payload Processing at KSC. Reporters also had the opportunity to see Space Station hardware that is being processed for deployment once the Space Shuttles return to flight. The facility tour also included an opportunity for reporters to talk with NASA and Boeing mission managers about the various hardware elements currently being processed for flight.

  10. The "Nursing Home Compare" measure of urinary/fecal incontinence: cross-sectional variation, stability over time, and the impact of case mix.

    PubMed

    Li, Yue; Schnelle, John; Spector, William D; Glance, Laurent G; Mukamel, Dana B

    2010-02-01

    To assess the impact of facility case mix on cross-sectional variations and short-term stability of the "Nursing Home Compare" incontinence quality measure (QM) and to determine whether multivariate risk adjustment can minimize such impacts. Retrospective analyses of the 2005 national minimum data set (MDS) that included approximately 600,000 long-term care residents in over 10,000 facilities in each quarterly sample. Mixed logistic regression was used to construct the risk-adjusted QM (nonshrinkage estimator). Facility-level ordinary least-squares models and adjusted R(2) were used to estimate the impact of case mix on cross-sectional and short-term longitudinal variations of currently published and risk-adjusted QMs. At least 50 percent of the cross-sectional variation and 25 percent of the short-term longitudinal variation of the published QM are explained by facility case mix. In contrast, the cross-sectional and short-term longitudinal variations of the risk-adjusted QM are much less susceptible to case-mix variations (adjusted R(2)<0.10), even for facilities with more extreme or more unstable outcome. Current "Nursing Home Compare" incontinence QM reflects considerable case-mix variations across facilities and over time, and therefore it may be biased. This issue can be largely addressed by multivariate risk adjustment using risk factors available in the MDS.

  11. CFD Simulation on the J-2X Engine Exhaust in the Center-Body Diffuser and Spray Chamber at the B-2 Facility

    NASA Technical Reports Server (NTRS)

    Wang, Xiao-Yen; Wey, Thomas; Buehrle, Robert

    2009-01-01

    A computational fluid dynamic (CFD) code is used to simulate the J-2X engine exhaust in the center-body diffuser and spray chamber at the Spacecraft Propulsion Facility (B-2). The CFD code is named as the space-time conservation element and solution element (CESE) Euler solver and is very robust at shock capturing. The CESE results are compared with independent analysis results obtained by using the National Combustion Code (NCC) and show excellent agreement.

  12. Control of large flexible structures - An experiment on the NASA Mini-Mast facility

    NASA Technical Reports Server (NTRS)

    Hsieh, Chen; Kim, Jae H.; Liu, Ketao; Zhu, Guoming; Skelton, Robert E.

    1991-01-01

    The output variance constraint controller design procedure is integrated with model reduction by modal cost analysis. A procedure is given for tuning MIMO controller designs to find the maximal rms performance of the actual system. Controller designs based on a finite-element model of the system are compared with controller designs based on an identified model (obtained using the Q-Markov Cover algorithm). The identified model and the finite-element model led to similar closed-loop performance, when tested in the Mini-Mast facility at NASA Langley.

  13. Autonomous Electrothermal Facility for Oil Recovery Intensification Fed by Wind Driven Power Unit

    NASA Astrophysics Data System (ADS)

    Belsky, Aleksey A.; Dobush, Vasiliy S.

    2017-10-01

    This paper describes the structure of autonomous facility fed by wind driven power unit for intensification of viscous and heavy crude oil recovery by means of heat impact on productive strata. Computer based service simulation of this facility was performed. Operational energy characteristics were obtained for various operational modes of facility. The optimal resistance of heating element of the downhole heater was determined for maximum operating efficiency of wind power unit.

  14. The care of Filipino juvenile offenders in residential facilities evaluated using the risk-need-responsivity model.

    PubMed

    Spruit, Anouk; Wissink, Inge B; Stams, Geert Jan J M

    2016-01-01

    According to the risk-need-responsivity model of offender, assessment and rehabilitation treatment should target specific factors that are related to re-offending. This study evaluates the residential care of Filipino juvenile offenders using the risk-need-responsivity model. Risk analyses and criminogenic needs assessments (parenting style, aggression, relationships with peers, empathy, and moral reasoning) have been conducted using data of 55 juvenile offenders in four residential facilities. The psychological care has been assessed using a checklist. Statistical analyses showed that juvenile offenders had a high risk of re-offending, high aggression, difficulties in making pro-social friends, and a delayed socio-moral development. The psychological programs in the residential facilities were evaluated to be poor. The availability of the psychological care in the facilities fitted poorly with the characteristics of the juvenile offenders and did not comply with the risk-need-responsivity model. Implications for research and practice are discussed. Copyright © 2016 Elsevier Ltd. All rights reserved.

  15. 40 CFR 61.31 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... associated elements. (b) Extraction plant means a facility chemically processing beryllium ore to beryllium..., electrochemical machining, etching, or other similar operations. (e) Ceramic plant means a manufacturing plant... which contains more than 0.1 percent beryllium by weight. (k) Propellant plant means any facility...

  16. 40 CFR 61.31 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... associated elements. (b) Extraction plant means a facility chemically processing beryllium ore to beryllium..., electrochemical machining, etching, or other similar operations. (e) Ceramic plant means a manufacturing plant... which contains more than 0.1 percent beryllium by weight. (k) Propellant plant means any facility...

  17. [Potential vulnerability to flooding at public health facilities in four northern regions of Peru].

    PubMed

    Hernández-Vásquez, Akram; Arroyo-Hernández, Hugo; Bendezú-Quispe, Guido; Díaz-Seijas, Deysi; Vilcarromero, Stalin; Rubilar-González, Juan; Gutierrez-Lagos, Edith

    2016-03-01

    In order to determine the potential vulnerability of public health facilities in four northern regions of Peru to the possible effects of El Niño-Southern Oscillation (ENSO) phenomenon. An exploratory spatial analysis was performed using the geo-referenced points for at-risk areas based on the activation of gullies that were reported by the National Water Authority, and the location of the four regional public health facilities of the Ministry of Health. Concentric areas of influence were simulate from the points of risk towards the public health facilities using radii of 200, 1000 and 1500 meters. The Tumbes region would be the most affected with 37.2% of its health facilities being affected by floods and landslides. The I-2 and I-3 categories of health facilities appeared to be the most affected with 28.9% and 31.6% respectively. Therefore, public health facilities near the risk zones may be affected by the ENSO.

  18. Soil Sample Report in Support of the Site 300 EWTF Ecological Risk Assessment and Permit Renewal-September 2012

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Terusaki, Stanley; Gallegos, Gretchen; MacQueen, Donald

    2012-10-02

    LLNL Site 300 has applied to renew the permits for its Explosives Waste Treatment Facility (EWTF), Explosives Waste Storage Facility (EWSF) and Building 883 Storage Facility. As a part of the permit renewal process, the Department of Toxic Substances Control (DTSC) requested LLNL to obtain soil samples in order to conduct a scoping-level ecological risk assessment pursuant to the Department of Toxic Substances Control, Guidance for Ecological Risk Assessment at Hazardous Waste Sites and Permitted Facilities, Part A: Overview, July 4, 1996. As stated in the guidance document, the scoping-level ecological risk assessment provides a framework to determine the potentialmore » interaction ecological receptors and chemicals of concern from hazardous waste treatment operations in the area of EWTF.« less

  19. Biopsychosocial Causes of Suicide and Suicide Prevention Outcome Studies in Juvenile Detention Facilities: A Review.

    PubMed

    Joshi, Kshamta; Billick, Stephen Bates

    2017-03-01

    To identify various biopsychosocial risk factors associated with suicidality in juvenile detention facilities and the effectiveness of suicide prevention protocols currently in use. Medical literature searches were conducted using databases like Pub Med, Ovid, and Google Scholar to identify studies conducted in and outside of United States. The prevalence of suicide among youth imprisoned at detention facilities has risen. Psychiatric disorders are common among such population, making them vulnerable to suicidal tendencies. Suicide risk screening within first 24 h of admission to the detention facility has shown to lower the risk of suicide. Identification of high risk individuals and their further psychiatric assessment is advocated. Much of work with regards to screening tools and instruments is underway and further study is required to get a better understanding.

  20. Space simulation facilities providing a stable thermal vacuum facility

    NASA Technical Reports Server (NTRS)

    Tellalian, Martin L.

    1990-01-01

    CBI has recently constructed the Intermediate Thermal Vacuum Facility. Built as a corporate facility, the installation will first be used on the Boost Surveillance and Tracking System (BSTS) program. It will also be used to develop and test other sensor systems. The horizontal chamber has a horseshoe shaped cross section and is supported on pneumatic isolators for vibration isolation. The chamber structure was designed to meet stability and stiffness requirements. The design process included measurement of the ambient ground vibrations, analysis of various foundation test article support configurations, design and analysis of the chamber shell and modal testing of the chamber shell. A detailed 3-D finite element analysis was made in the design stage to predict the lowest three natural frequencies and mode shapes and to identify local vibrating components. The design process is described and the results are compared of the finite element analysis to the results of the field modal testing and analysis for the 3 lowest natural frequencies and mode shapes. Concepts are also presented for stiffening large steel structures along with methods to improve test article stability in large space simulation facilities.

  1. The U.S. Geological Survey's TRIGA® reactor

    USGS Publications Warehouse

    DeBey, Timothy M.; Roy, Brycen R.; Brady, Sally R.

    2012-01-01

    The U.S. Geological Survey (USGS) operates a low-enriched uranium-fueled, pool-type reactor located at the Federal Center in Denver, Colorado. The mission of the Geological Survey TRIGA® Reactor (GSTR) is to support USGS science by providing information on geologic, plant, and animal specimens to advance methods and techniques unique to nuclear reactors. The reactor facility is supported by programs across the USGS and is organizationally under the Associate Director for Energy and Minerals, and Environmental Health. The GSTR is the only facility in the United States capable of performing automated delayed neutron analyses for detecting fissile and fissionable isotopes. Samples from around the world are submitted to the USGS for analysis using the reactor facility. Qualitative and quantitative elemental analyses, spatial elemental analyses, and geochronology are performed. Few research reactor facilities in the United States are equipped to handle the large number of samples processed at the GSTR. Historically, more than 450,000 sample irradiations have been performed at the USGS facility. Providing impartial scientific information to resource managers, planners, and other interested parties throughout the world is an integral part of the research effort of the USGS.

  2. Can-AMS: The New Accelerator Mass Spectrometry Facility At The University Of Ottawa

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kieser, W. E.; Zhao, X.-L.; Clark, I. D.

    2011-06-01

    The Canadian Centre for Accelerator Mass Spectrometry (AMS) at the University of Ottawa will be equipped with a new, 3 MV tandem accelerator with peripheral equipment for the analysis of elements ranging from tritium to the actinides. This facility, along with a wide array of support instrumentation recently funded by the Canada Foundation for Innovation, will be located in a new science building on the downtown campus of the University of Ottawa. In addition to providing the standard AMS measurements on {sup 14}C, {sup 10}Be, {sup 26}Al, {sup 36}Cl and {sup 129}I for earth, environmental, cultural and biomedical sciences, thismore » facility will incorporate the new technologies of anion isobar separation at low energies using RFQ chemical reaction cells for {sup 36}Cl and new heavy element applications, integrated sample combustion and gas ion source for biomedical and environmental {sup 14}C analysis and the use of novel target matrices for expanding the range of applicable elements and simplifying sample preparation, all currently being developed at IsoTrace. This paper will outline the design goals for the new facility, present some details of the new AMS technologies, in particular the Isobar Separator for Anions and discuss the design of the AMS system resulting from these requirements.« less

  3. Radioactively Contaminated Sites | RadTown USA | US EPA

    EPA Pesticide Factsheets

    2018-01-12

    If radioactive materials are used or disposed of improperly, they can contaminate buildings and the environment. Every site requiring cleanup is different depending on the type of facility, the radioactive elements involved and the concentration of the radioactive elements.

  4. Trace Elements: The Little Things that Count

    ERIC Educational Resources Information Center

    Evans, Gary W.

    1977-01-01

    Examines recent findings regarding the importance of trace elements to good health. Copper, chromium, and zinc are discussed. Described also are multi-disciplinary experiments in progress at the Human Nutrition Laboratory, a federal facility in Grand Forks, North Dakota. (CS)

  5. Cancer Risks near Nuclear Facilities: The Importance of Research Design and Explicit Study Hypotheses

    PubMed Central

    Wing, Steve; Richardson, David B.; Hoffmann, Wolfgang

    2011-01-01

    Background In April 2010, the U.S. Nuclear Regulatory Commission asked the National Academy of Sciences to update a 1990 study of cancer risks near nuclear facilities. Prior research on this topic has suffered from problems in hypothesis formulation and research design. Objectives We review epidemiologic principles used in studies of generic exposure–response associations and in studies of specific sources of exposure. We then describe logical problems with assumptions, formation of testable hypotheses, and interpretation of evidence in previous research on cancer risks near nuclear facilities. Discussion Advancement of knowledge about cancer risks near nuclear facilities depends on testing specific hypotheses grounded in physical and biological mechanisms of exposure and susceptibility while considering sample size and ability to adequately quantify exposure, ascertain cancer cases, and evaluate plausible confounders. Conclusions Next steps in advancing knowledge about cancer risks near nuclear facilities require studies of childhood cancer incidence, focus on in utero and early childhood exposures, use of specific geographic information, and consideration of pathways for transport and uptake of radionuclides. Studies of cancer mortality among adults, cancers with long latencies, large geographic zones, and populations that reside at large distances from nuclear facilities are better suited for public relations than for scientific purposes. PMID:21147606

  6. Successful Completion of the JWST OGSE2 Cryogenic Test at JSC Chamber-A While Managing Numerous Challenges

    NASA Technical Reports Server (NTRS)

    Park, Sang C.; Brinckerhoff, Pamela; Franck, Randy; Schweickart, Rusty; Thomson, Shaun; Burt, Bill; Ousley, Wes

    2016-01-01

    The James Webb Space Telescope (JWST) Optical Telescope Element (OTE) assembly is the largest optically stable infrared-optimized telescope currently being manufactured and assembled, and scheduled for launch in 2018. The JWST OTE, including the primary mirrors, secondary mirror, and the Aft Optics Subsystems (AOS) are designed to be passively cooled and operate at near 45 degrees Kelvin. Due to the size of its large sunshield in relation to existing test facilities, JWST cannot be optically or thermally tested as a complete observatory-level system at flight temperatures. As a result, the telescope portion along with its instrument complement will be tested as a single unit very late in the program, and on the program schedule critical path. To mitigate schedule risks, a set of 'pathfinder' cryogenic tests will be performed to reduce program risks by demonstrating the optical testing capabilities of the facility, characterizing telescope thermal performance, and allowing project personnel to learn valuable testing lessons off-line. This paper describes the 'pathfinder' cryogenic test program, focusing on the recently completed second test in the series called the Optical Ground Support Equipment 2 (OGSE2) test. The JWST OGSE2 was successfully completed within the allocated project schedule while faced with numerous conflicting thermal requirements during cool-down to the final cryogenic operational temperatures, and during warm-up after the cryo-stable optical tests. The challenges include developing a pre-test cool-down and warm-up profiles without a reliable method to predict the thermal behaviors in a rarified helium environment, and managing the test article hardware safety driven by the project Limits and Constraints (L&C's). Furthermore, OGSE2 test included the time critical Aft Optics Subsystem (AOS), a part of the flight Optical Telescope Element that would need to be placed back in the overall telescope assembly integrations. The OGSE2 test requirements included the strict adherence of the project contamination controls due to the presence of the contamination sensitive flight optical elements. The test operations required close coordination of numerous personnel while they being exposed and trained for the 'final' combined OTE and instrument cryo-test in 2017. This paper will also encompass the OGSE2 thermal data look-back review.

  7. Systematic, appropriate, and cost-effective application of security technologies in U.S. public schools to reduce crime, violence, and drugs

    NASA Astrophysics Data System (ADS)

    Green, Mary W.

    1997-01-01

    As problems of violence and crime become more prevalent in our schools, more and more school districts will elect to use security technologies to control these problems. While the desired change in student and community attitudes will require significant systemic change through intense US social programs, security technologies can greatly augment school staff today by providing services similar to having extra adults present. Technologies such as cameras, sensors, drug detection, biometric and personnel identification, lighting, barriers, weapon and explosives detection, anti- graffiti methods, and duress alarms can all be effective, given they are used in appropriate applications, with realistic expectations and an understanding of limitations. Similar to a high-risk government facility, schools must consider a systems approach to security, which includes the use of personnel and procedures as well as security technologies, such that the synergy created by all these elements together contributes more tot he general 'order maintenance' of the facility than could be achieved by separate measures not integrated or related.

  8. Prioritization methodology for the decommissioning of nuclear facilities: a study case on the Iraq former nuclear complex.

    PubMed

    Jarjies, Adnan; Abbas, Mohammed; Monken Fernandes, Horst; Wong, Melanie; Coates, Roger

    2013-05-01

    There are a number of sites in Iraq which have been used for nuclear activities and which contain potentially significant amounts of radioactive waste. The principal nuclear site being Al-Tuwaitha. Many of these sites suffered substantial physical damage during the Gulf Wars and have been subjected to subsequent looting. All require decommissioning in order to ensure both radiological and non-radiological safety. However, it is not possible to undertake the decommissioning of all sites and facilities at the same time. Therefore, a prioritization methodology has been developed in order to aid the decision-making process. The methodology comprises three principal stages of assessment: i) a quantitative surrogate risk assessment ii) a range of sensitivity analyses and iii) the inclusion of qualitative modifying factors. A group of Tuwaitha facilities presented the highest risk among the evaluated ones, followed by a middle ranking grouping of Tuwaitha facilities and some other sites, and a relatively large group of lower risk facilities and sites. The initial order of priority is changed when modifying factors are taken into account. It has to be considered the Iraq's isolation from the international nuclear community over the last two decades and the lack of experienced personnel. Therefore it is appropriate to initiate decommissioning operations on selected low risk facilities at Tuwaitha in order to build capacity and prepare for work to be carried out in more complex and potentially high hazard facilities. In addition it is appropriate to initiate some prudent precautionary actions relating to some of the higher risk facilities. Copyright © 2012 Elsevier Ltd. All rights reserved.

  9. High energy forming facility

    NASA Technical Reports Server (NTRS)

    Ciurlionis, B.

    1967-01-01

    Watertight, high-explosive forming facility, 25 feet in diameter and 15 feet deep, withstands repeated explosions of 10 pounds of TNT equivalent. The shell is fabricated of high strength steel and allows various structural elements to deform or move elastically and independently while retaining structural integrity.

  10. Senator Doug Jones (D-AL) Tour of MSFC Facilities

    NASA Image and Video Library

    2018-02-22

    Senator Doug Jones (D-AL.) and wife, Louise, tour Marshall Space Flight facilities. Steve Doering, manager, Stages Element, Space Launch System (SLS) program at MSFC, along with Senator and Mrs. Jones, viewed the MSFC campus from the top of test stand 4693.

  11. Environmental monitoring and research at the John F. Kennedy Space Center

    NASA Technical Reports Server (NTRS)

    Hall, C. R.; Hinkle, C. R.; Knott, W. M.; Summerfield, B. R.

    1992-01-01

    The Biomedical Operations and Research Office at the NASA John F. Kennedy Space Center has been supporting environmental monitoring and research since the mid-1970s. Program elements include monitoring of baseline conditions to document natural variability in the ecosystem, assessments of operations and construction of new facilities, and ecological research focusing on wildlife habitat associations. Information management is centered around development of a computerized geographic information system that incorporates remote sensing and digital image processing technologies along with traditional relational data base management capabilities. The proactive program is one in which the initiative is to anticipate potential environmental concerns before they occur and, by utilizing in-house expertise, develop impact minimization or mitigation strategies to reduce environmental risk.

  12. KSC-01pp0488

    NASA Image and Video Library

    2001-03-13

    Arrays of lights (left) in the Spacecraft Assembly and Encapsulation Facility (SAEF 2) are used for illumination testing on the solar array panels at right. The panels are part of on the 2001 Mars Odyssey Orbiter. Scheduled for launch April 7, 2001, the orbiter contains three science instruments: THEMIS, the Gamma Ray Spectrometer (GRS), and the Mars Radiation Environment Experiment (MARIE). THEMIS will map the mineralogy and morphology of the Martian surface using a high-resolution camera and a thermal infrared imaging spectrometer. The GRS will achieve global mapping of the elemental composition of the surface and determine the abundance of hydrogen in the shallow subsurface. The MARIE will characterize aspects of the near-space radiation environment with regards to the radiation-related risk to human explorers

  13. KSC-01pp0490

    NASA Image and Video Library

    2001-03-13

    Workers testing in the Spacecraft Assembly and Encapsulation Facility (SAEF 2) stand alongside the 2001 Mars Odyssey Orbiter and behind its solar array panels. The arrays of lights (right) focus on the panels during illumination testing. Scheduled for launch April 7, 2001, the orbiter contains three science instruments: THEMIS, the Gamma Ray Spectrometer (GRS), and the Mars Radiation Environment Experiment (MARIE). THEMIS will map the mineralogy and morphology of the Martian surface using a high-resolution camera and a thermal infrared imaging spectrometer. The GRS will achieve global mapping of the elemental composition of the surface and determine the abundance of hydrogen in the shallow subsurface. The MARIE will characterize aspects of the near-space radiation environment with regards to the radiation-related risk to human explorers

  14. Thermal/structural design verification strategies for large space structures

    NASA Technical Reports Server (NTRS)

    Benton, David

    1988-01-01

    Requirements for space structures of increasing size, complexity, and precision have engendered a search for thermal design verification methods that do not impose unreasonable costs, that fit within the capabilities of existing facilities, and that still adequately reduce technical risk. This requires a combination of analytical and testing methods. This requires two approaches. The first is to limit thermal testing to sub-elements of the total system only in a compact configuration (i.e., not fully deployed). The second approach is to use a simplified environment to correlate analytical models with test results. These models can then be used to predict flight performance. In practice, a combination of these approaches is needed to verify the thermal/structural design of future very large space systems.

  15. 6 CFR 27.205 - Determination that a chemical facility “presents a high level of security risk.”

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... a high level of security risk.â 27.205 Section 27.205 Domestic Security DEPARTMENT OF HOMELAND... Program § 27.205 Determination that a chemical facility “presents a high level of security risk.” (a... a high level of security risk based on any information available (including any information...

  16. TREE Simulation Facilities, Second Edition, Revision 2

    DTIC Science & Technology

    1979-01-01

    included radiation effects on propellants , ordnance, electronics and chemicals, vehicle shielding, neutron radiography , dosimetry, and health physics...Special Capabilities 2.11.10.1 Radiography Facility 2.11.10.2 Flexo-Rabbit System Support Capabilities 2.11.11.1 Staff 2.11.11.2 Electronics...5,400-MW pulsing operation (experimental dosimetry values for a typical core loading of 94 fuel elements). 2-156 2-46 ACPR radiography facility

  17. DEVELOPMENT OF THE METAL FINISHING FACILITY RISK SCREENING TOOL (MFFRST)

    EPA Science Inventory

    Recently the US EPA completed the development of the first version of the Metal Finishing Facility Risk Screening Tool (MFFRST) and has made this product available to the general public. MFFRST calculates the air emissions from a metal plating line and determines the risk to bot...

  18. Strategic avionics technology definition studies. Subtask 3-1A3: Electrical Actuation (ELA) Systems Test Facility

    NASA Technical Reports Server (NTRS)

    Rogers, J. P.; Cureton, K. L.; Olsen, J. R.

    1994-01-01

    Future aerospace vehicles will require use of the Electrical Actuator systems for flight control elements. This report presents a proposed ELA Test Facility for dynamic evaluation of high power linear Electrical Actuators with primary emphasis on Thrust Vector Control actuators. Details of the mechanical design, power and control systems, and data acquisition capability of the test facility are presented. A test procedure for evaluating the performance of the ELA Test Facility is also included.

  19. Differences in Colonoscopy Quality Among Facilities: Development of a Post-Colonoscopy Risk-Standardized Rate of Unplanned Hospital Visits.

    PubMed

    Ranasinghe, Isuru; Parzynski, Craig S; Searfoss, Rana; Montague, Julia; Lin, Zhenqiu; Allen, John; Vender, Ronald; Bhat, Kanchana; Ross, Joseph S; Bernheim, Susannah; Krumholz, Harlan M; Drye, Elizabeth E

    2016-01-01

    Colonoscopy is a common procedure, yet little is known about variations in colonoscopy quality among outpatient facilities. We developed an outcome measure to profile outpatient facilities by estimating risk-standardized rates of unplanned hospital visits within 7 days of colonoscopy. We used a 20% sample of 2010 Medicare outpatient colonoscopy claims (331,880 colonoscopies performed at 8140 facilities) from patients ≥65 years or older, and developed a patient-level logistic regression model to estimate the risk of unplanned hospital visits (ie, emergency department visits, observation stays, and inpatient admissions) within 7 days of colonoscopy. We then used the patient-level risk model variables and hierarchical logistic regression to estimate facility rates of risk-standardized unplanned hospital visits using data from the Healthcare Cost and Utilization Project (325,811 colonoscopies at 992 facilities), from 4 states containing 100% of colonoscopies per facility. Outpatient colonoscopies were followed by 5412 unplanned hospital visits within 7 days (16.3/1000 colonoscopies). Hemorrhage, abdominal pain, and perforation were the most common causes of unplanned hospital visits. Fifteen variables were independently associated with unplanned hospital visits (c = 0.67). A history of fluid and electrolyte imbalance (odds ratio [OR] = 1.43; 95% confidence interval [CI]: 1.29-1.58), psychiatric disorders (OR = 1.34; 95% CI: 1.22-1.46), and, in the absence of prior arrhythmia, increasing age past 65 years (aged >85 years vs 65-69 years: OR = 1.87; 95% CI: 1.54-2.28) were most strongly associated. The facility risk-standardized unplanned hospital visits calculated using Healthcare Cost and Utilization Project data showed significant variation (median 12.3/1000; 5th-95th percentile, 10.5-14.6/1000). Median risk-standardized unplanned hospital visits were comparable between ambulatory surgery centers and hospital outpatient departments (each was 10.2/1000), and ranged from 16.1/1000 in the Northeast to 17.2/1000 in the Midwest. We calculated a risk-adjusted measure of outpatient colonoscopy quality, which shows important variation in quality among outpatient facilities. This measure can make transparent the extent to which patients require follow-up hospital care, help inform patient choices, and assist in quality-improvement efforts. Copyright © 2016 AGA Institute. Published by Elsevier Inc. All rights reserved.

  20. Validation of a model for ranking aquaculture facilities for risk-based disease surveillance.

    PubMed

    Diserens, Nicolas; Falzon, Laura Cristina; von Siebenthal, Beat; Schüpbach-Regula, Gertraud; Wahli, Thomas

    2017-09-15

    A semi-quantitative model for risk ranking of aquaculture facilities in Switzerland with regard to the introduction and spread of Viral Haemorrhagic Septicaemia (VHS) and Infectious Haematopoietic Necrosis (IHN) was developed in a previous study (Diserens et al., 2013). The objective of the present study was to validate this model using data collected during field visits on aquaculture sites in four Swiss cantons compared to data collected through a questionnaire in the previous study. A discrepancy between the values obtained with the two different methods was found in 32.8% of the parameters, resulting in a significant difference (p<0.001) in the risk classification of the facilities. As data gathered exclusively by means of a questionnaire are not of sufficient quality to perform a risk-based surveillance of aquaculture facilities a combination of questionnaires and farm inspections is proposed. A web-based reporting system could be advantageous for the factors which were identified as being more likely to vary over time, in particular for factors considering fish movements, which showed a marginally significant difference in their risk scores (p≥0.1) within a six- month period. Nevertheless, the model proved to be stable over the considered period of time as no substantial fluctuations in the risk categorisation were observed (Kappa agreement of 0.77).Finally, the model proved to be suitable to deliver a reliable risk ranking of Swiss aquaculture facilities according to their risk of getting infected with or spreading of VHS and IHN, as the five facilities that tested positive for these diseases in the last ten years were ranked as medium or high risk. Moreover, because the seven fish farms that were infected with Infectious Pancreatic Necrosis (IPN) during the same period also belonged to the risk categories medium and high, the classification appeared to correlate with the occurrence of this third viral fish disease. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Industrial Control Systems/SCADA systems risk assessment in the energy sector

    NASA Astrophysics Data System (ADS)

    Falodun, Babatunde

    The energy sector is one of the most critical components of our national infrastructure. It not only provides the electrical power and petroleum required to run day-to-day operations and mechanisms in society, it's also an important element that directly impacts the economy with regard to growth and stability. Industrial Control Systems (ICS) /Supervisory Control and Data Acquisition Systems (SCADA) are computerized mechanisms, they are both software and hardware that are used to control real time processes and operations in power plants and oil production facilities. A significant attack on these control systems that leads to widespread disruption of energy could result in catastrophic consequences for any major city and even the nation. This research paper explores cyber threats and vulnerabilities faced by ICS/SCADA systems in the energy sector and also highlights possible outcomes of a successful breach. Furthermore, the research underscores mitigation strategies that could be used to prevent and respond to an attack. Keywords: Cybersecurity, SCADA, Cyber Attacks, Threats, Vulnerabilities, Risk Assessment, Dr. Albert Orbinati.

  2. Drug-nutrient interactions in three long-term-care facilities.

    PubMed

    Lewis, C W; Frongillo, E A; Roe, D A

    1995-03-01

    To assess the risk of drug-nutrient interactions (DNIs) in three long-term-care facilities. Retrospective audit of charts. Three long-term-care facilities in central New York State. Fifty-three patients selected randomly from each facility. Data were collected from the medical record of each patient for a period of 6 months. A computerized algorithm was used to assess the risk for DNIs. Mean drug use, most frequently consumed drugs, incidence of potential DNIs, and the most commonly observed potential DNIs are reported. In facilities A, B, and C, respectively, patients consumed a mean of 4.86, 4.04, and 5.27 drugs per patient per month and were at risk for a mean of 1.43, 2.69, and 1.43 potential DNIs per patient per month. The most commonly observed potential DNIs were gastrointestinal interactions affecting drug bioavailability and interactions affecting electrolyte status. Patients in long-term-care facilities, who are primarily elderly and chronically ill and who consume multiple medications, are at notable risk for certain DNIs. Efforts need to be made to ensure appropriate pharmacologic and nutrition therapies as well as adequate and timely monitoring of patients in these facilities. Dietitians can play an important role in training other health professionals and in designing policies to prevent DNIs.

  3. The Study Elements and Indicators of Risk Management System for Secondary Schools in Thailand

    ERIC Educational Resources Information Center

    Wandee, Methenan; Sirisuthi, Chaiyuth; Leamvijarn, Subunn

    2017-01-01

    The purposes of this research aimed 1) to study the elements and indicators of risk management system for secondary schools in Thailand. 2) to study suitable the elements and indicators of the risk management system for secondary schools in Thailand. 3) to study the results of CFA (Confirmatory Factors Analysis) risk management process of risk…

  4. Fact Sheet for Friction Materials Manufacturing Facilities Residual Risk and Technology Review

    EPA Pesticide Factsheets

    proposed amendments to the National Emission Standards for Hazardous Air Pollutants (NESHAP) for Friction Materials Manufacturing Facilities to address the results of the residual risk and technology review

  5. Risk assessment and optimization (ALARA) analysis for the environmental remediation of Brookhaven National Laboratory`s hazardous waste management facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dionne, B.J.; Morris, S.C. III; Baum, J.W.

    1998-01-01

    The Department of Energy`s (DOE) Office of Environment, Safety, and Health (EH) sought examples of risk-based approaches to environmental restoration to include in their guidance for DOE nuclear facilities. Extensive measurements of radiological contamination in soil and ground water have been made at Brookhaven National Laboratory`s Hazardous Waste Management Facility (HWMF) as part of a Comprehensive Environmental Response, Compensation and Liability Act (CERCLA) remediation process. This provided an ideal opportunity for a case study. This report provides a risk assessment and an {open_quotes}As Low as Reasonably Achievable{close_quotes} (ALARA) analysis for use at other DOE nuclear facilities as an example ofmore » a risk-based decision technique. This document contains the Appendices for the report.« less

  6. Intermodal Freight Plan: The Goods Movement Element of the DVRPC Year 2020 Plan

    DOT National Transportation Integrated Search

    1995-06-01

    The focus of this plan is the twenty-three significant intermodal facilities in the Delaware Valley region where freight is exchanged between modes of transport en route to its final destination. A catalogue of these facilities and their supporting n...

  7. 78 FR 74106 - Announcement of Federal Interagency Competition, Fiscal Year 2014 Investing in Manufacturing...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-10

    ... training facilities and services; community facilities and other community development projects. In REDLG a... assistance offered by IMCP participating agencies. Some Manufacturing Communities, as discussed in the... integrated investments and relationships among the following elements: Workforce and training; Supplier...

  8. Senator Doug Jones (D-AL) Tour of MSFC Facilities

    NASA Image and Video Library

    2018-02-22

    Senator Doug Jones (D-AL.) and wife, Louise, tour Marshall Space Flight facilities. Steve Doering, manager, Stages Element, Space Launch System (SLS) program at MSFC, explains the stages of the SLS rocket with the scale model rocket located in the lobby of building 4200.

  9. The development of the Canadian Mobile Servicing System Kinematic Simulation Facility

    NASA Technical Reports Server (NTRS)

    Beyer, G.; Diebold, B.; Brimley, W.; Kleinberg, H.

    1989-01-01

    Canada will develop a Mobile Servicing System (MSS) as its contribution to the U.S./International Space Station Freedom. Components of the MSS will include a remote manipulator (SSRMS), a Special Purpose Dexterous Manipulator (SPDM), and a mobile base (MRS). In order to support requirements analysis and the evaluation of operational concepts related to the use of the MSS, a graphics based kinematic simulation/human-computer interface facility has been created. The facility consists of the following elements: (1) A two-dimensional graphics editor allowing the rapid development of virtual control stations; (2) Kinematic simulations of the space station remote manipulators (SSRMS and SPDM), and mobile base; and (3) A three-dimensional graphics model of the space station, MSS, orbiter, and payloads. These software elements combined with state of the art computer graphics hardware provide the capability to prototype MSS workstations, evaluate MSS operational capabilities, and investigate the human-computer interface in an interactive simulation environment. The graphics technology involved in the development and use of this facility is described.

  10. KENNEDY SPACE CENTER, FLA. - NASA Manager Steve Cain explains aspects of Space Shuttle processing to Consul General of Japan Ko Kodaira and his family in the Orbiter Processing Facility during their visit to Kennedy Space Center (KSC). From left are Kodaira's wife Marie, his daughter Reiko, Kodaira, and Cain, Senior Future International Space Station Element Manager. Kodaira is touring the facilities at KSC at the invitation of the local office of the National Space Development Agency of Japan (NASDA) to acquaint him with KSC's unique processing capabilities.

    NASA Image and Video Library

    2003-08-26

    KENNEDY SPACE CENTER, FLA. - NASA Manager Steve Cain explains aspects of Space Shuttle processing to Consul General of Japan Ko Kodaira and his family in the Orbiter Processing Facility during their visit to Kennedy Space Center (KSC). From left are Kodaira's wife Marie, his daughter Reiko, Kodaira, and Cain, Senior Future International Space Station Element Manager. Kodaira is touring the facilities at KSC at the invitation of the local office of the National Space Development Agency of Japan (NASDA) to acquaint him with KSC's unique processing capabilities.

  11. Preliminary impact assessment of effusive eruptions at Etna volcano

    NASA Astrophysics Data System (ADS)

    Cappello, Annalisa; Michaud-Dubuy, Audrey; Branca, Stefano; De Beni, Emanuela; Del Negro, Ciro

    2016-04-01

    Lava flows are a recurring and widespread form of volcanic activity that threaten people and property around the world. The growing demographic congestion around volcanic structures increases the potential risks and costs that lava flows represent, and leads to a pressing need for faster and more accurate assessment of lava flow impact. To fully evaluate potential effects and losses that an effusive eruption may cause to society, property and environment, it is necessary to consider the hazard, the distribution of the exposed elements at stake and the associated vulnerability. Lava flow hazard assessment is at an advanced state, whereas comprehensive vulnerability assessment is lacking. Cataloguing and analyzing volcanic impacts provide insight on likely societal and physical vulnerabilities during future eruptions. Here we quantify the lava flow impact of two past main effusive eruptions of Etna volcano: the 1669, which is the biggest and destructive flank eruption to have occurred on Etna in historical time, and the 1981, lasting only 6 days, but characterized by an intense eruptive dynamics. Different elements at stake are considered, including population, hospitals, critical facilities, buildings of historic value, industrial infrastructures, gas and electricity networks, railways, roads, footways and finally land use. All these elements were combined with the 1669 and 1981 lava flow fields to quantify the social damage and economic loss.

  12. Sources, behaviour, and environmental and human health risks of high-technology rare earth elements as emerging contaminants.

    PubMed

    Gwenzi, Willis; Mangori, Lynda; Danha, Concilia; Chaukura, Nhamo; Dunjana, Nothando; Sanganyado, Edmond

    2018-04-26

    Recent studies show that high-technology rare earth elements (REEs) of anthropogenic origin occur in the environment including in aquatic systems, suggesting REEs are contaminants of emerging concern. However, compared to organic contaminants, there is a lack of comprehensive reviews on the anthropogenic sources, environmental behaviour, and public and ecological health risks of REEs. The current review aims to: (1) identify anthropogenic sources, transfer mechanisms, and environmental behaviour of REEs; (2) highlight the human and ecological health risks of REEs and propose mitigation measures; and (3) identify knowledge gaps and future research directions. Out of the 17 REEs, La, Gd, Ce and Eu are the most studied. The main sources of anthropogenic REE include; medical facilities, petroleum refining, mining and technology industries, fertilizers, livestock feeds, and electronic wastes and recycling plants. REEs are mobilized and transported in the environment by hydrological and wind-driven processes. Ecotoxicological effects include reduced plant growth, function and nutritional quality, genotoxicity and neurotoxicity in animals, trophic bioaccumulation, chronic and acute toxicities in soil organisms. Human exposure to REEs occurs via ingestion of contaminated water and food, inhalation, and direct intake during medical administration. REEs have been detected in human hair, nails, and biofluids. In humans, REEs cause nephrogenic systemic fibrosis and severe damage to nephrological systems associated with Gd-based contrast agents, dysfunctional neurological disorder, fibrotic tissue injury, oxidative stress, pneumoconiosis, cytotoxicity, anti-testicular effects, and male sterility. Barring REEs in medical devices, epidemiological evidence directly linking REEs in the environment to human health conditions remains weak. To minimize health risks, a conceptual framework and possible mitigation measures are highlighted. Future research is needed to better understand sources, environmental behaviour, ecotoxicology, and human epidemiology. Moreover, research on REEs in developing regions, including Africa, is needed given prevailing conditions predisposing humans to health risks (e.g., untreated drinking water). Copyright © 2018 Elsevier B.V. All rights reserved.

  13. NENIMF: Northeast National Ion Microprobe Facility - A Multi-User Facility for SIMS Microanalysis

    NASA Astrophysics Data System (ADS)

    Layne, G. D.; Shimizu, N.

    2002-12-01

    The MIT-Brown-Harvard Regional Ion Microprobe Facility was one of the earliest multi-user facilities enabled by Dan Weill's Instrumentation and Facilities Program - and began with the delivery of a Cameca IMS 3f ion microprobe to MIT in 1978. The Northeast National Ion Microprobe Facility (NENIMF) is the direct descendant of this original facility. Now housed at WHOI, the facility incorporates both the original IMS 3f, and a new generation, high transmission-high resolution instrument - the Cameca IMS 1270. Purchased with support from NSF, and from a consortium of academic institutions in the Northeast (The American Museum of Natural History, Brown University, The Lamont-Doherty Earth Observatory, MIT, Rensselaer Polytechnic Institute, WHOI) - this latest instrument was delivered and installed during 1996. NENIMF continues to be supported by NSF EAR I&F as a multi-user facility for geochemical research. Work at NENIMF has extended the original design strength of the IMS 1270 for microanalytical U-Pb zircon geochronology to a wide variety of novel and improved techniques for geochemical research. Isotope microanalysis for studies in volcanology and petrology is currently the largest single component of facility activity. This includes the direct measurement of Pb isotopes in melt inclusions, an application developed at NENIMF, which is making an increasingly significant contribution to our understanding of basalt petrogenesis. This same technique has also been extended to the determination of Pb isotopes in detrital feldspar grains, for the study of sedimentary provenance and tectonics of the Himalayas and other terrains. The determination of δ11B in volcanic melt inclusions has also proven to be a powerful tool in the modeling of subduction-related magmatism. The recent development of δ34S and δ37Cl determination in glasses is being applied to studies of the behavior of these volatile elements in both natural and experimental systems. Other recent undertakings have included development of high precision 232Th/230Th for U-series disequilibrium studies of young volcanic rocks, and the implementation and refinement of U-Th-Pb dating of individual monazite crystals. The facility is also developing an expanding number of applications in the general field of biogeochemistry. Examples include; δ18O in biogenic carbonates for climate and paleotemperature studies, determination of δ13C in graphite microfossils for early life studies, and determination of δ13C and trace metal concentrations in bacterial cultures in support of studies of natural microbial ecosystems. The IMS 3f instrument - now in its 25th year of operation - continues to be a productive resource for trace element and rare earth element determinations in natural and experimental materials. It has also become an important component of ongoing research in the derivation of paleotemperatures from marine biomineralization using trace element ratios of biogenic aragonite.

  14. Centrifuge facility conceptual system study. Volume 2: Facility systems and study summary

    NASA Technical Reports Server (NTRS)

    Synnestvedt, Robert (Editor); Blair, Patricia; Cartledge, Alan; Garces-Porcile, Jorge; Garin, Vladimir; Guerrero, Mike; Haddeland, Peter; Horkachuck, Mike; Kuebler, Ulrich; Nguyen, Frank

    1991-01-01

    The Centrifuge Facility is a major element of the biological research facility for the implementation of NASA's Life Science Research Program on Space Station Freedom using nonhuman species (small primates, rodents, plants, insects, cell tissues, etc.). The Centrifuge Facility consists of a variable gravity Centrifuge to provide artificial gravity up to 2 earth G's' a Holding System to maintain specimens at microgravity levels, a Glovebox, and a Service Unit for servicing specimen chambers. The following subject areas are covered: (1) Holding System; (2) Centrifuge System; (3) Glovebox System; (4) Service System; and (5) system study summary.

  15. Are environmental risk estimations linked to the actual environmental impact? Application to an oil handling facility (NE Spain).

    PubMed

    Valdor, Paloma F; Puente, Araceli; Gómez, Aina G; Ondiviela, Bárbara; Juanes, José A

    2017-01-30

    The environmental risk analysis of aquatic systems includes the evaluation of the likelihood that adverse ecological effects may occur as a result of exposure to one or more stressors. In harbor areas, pollution is provided by a complex mixture of substances with different levels of toxicity, persistence and bioaccumulation, which complicates the hazards characterization and their multiple effects. A study of the relationship between the environmental impact and the environmental risk assessment at a specific isolated oil handling facility was undertaken. The environmental risk of the oil handling facility, considering the consequences of specific pollutants, was estimated and the associated environmental impact was quantified based on a 'weights of evidence' approach. The contamination quantified at the potentially affected area around the monobuoy of Tarragona has proved to be related with environmental risk estimations but the lines of evidence obtained do not allow us to assert that the activity developed at this facility has an associated environmental impact. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. Initial research program for the National Transonic Facility

    NASA Technical Reports Server (NTRS)

    Gloss, B. B.

    1984-01-01

    The construction and checkout of the National Transonic Facility (NTF) have been completed, and detailed calibration is now in progress. The initial NTF research program covers a wide range of study areas falling into three major elements: (1) the assessment of Reynolds number sensitivities for a broad range of configurations and flow phenomena; (2) validation of the ability of NTF to simulate full-scale aerodynamics; and (3) the development of test techniques for improved test simulations in existing wind tunnels. This paper, therefore, is a status report on these various elements of the initial NTF research program.

  17. Guide to Permitting Hydrogen Motor Fuel Dispensing Facilities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rivkin, Carl; Buttner, William; Burgess, Robert

    2016-03-28

    The purpose of this guide is to assist project developers, permitting officials, code enforcement officials, and other parties involved in developing permit applications and approving the implementation of hydrogen motor fuel dispensing facilities. The guide facilitates the identification of the elements to be addressed in the permitting of a project as it progresses through the approval process; the specific requirements associated with those elements; and the applicable (or potentially applicable) codes and standards by which to determine whether the specific requirements have been met. The guide attempts to identify all applicable codes and standards relevant to the permitting requirements.

  18. Addressing social aspects associated with wastewater treatment facilities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Padilla-Rivera, Alejandro; Morgan-Sagastume, Juan Manuel; Noyola, Adalberto

    In wastewater treatment facilities (WWTF), technical and financial aspects have been considered a priority, while other issues, such as social aspects, have not been evaluated seriously and there is not an accepted methodology for assessing it. In this work, a methodology focused on social concerns related to WWTF is presented. The methodology proposes the use of 25 indicators as a framework for measuring social performance to evaluate the progress in moving towards sustainability. The methodology was applied to test its applicability and effectiveness in two WWTF in Mexico (urban and rural). This evaluation helped define the key elements, stakeholders andmore » barriers in the facilities. In this context, the urban facility showed a better overall performance, a result that may be explained mainly by the better socioeconomic context of the urban municipality. Finally, the evaluation of social aspects using the semi-qualitative approach proposed in this work allows for a comparison between different facilities and for the identification of strengths and weakness, and it provides an alternative tool for achieving and improving wastewater management. - Highlights: • The methodology proposes 25 indicators as a framework for measuring social performance in wastewater treatment facilities. • The evaluation helped to define the key elements, stakeholders and barriers in the wastewater treatment facilities. • The evaluation of social aspects allows the identification of strengths and weakness for improving wastewater management. • It provides a social profile of the facility that highlights the best and worst performances.« less

  19. Environmental Assessment: Proposed Training Facilities, Hill Air Force Base, Utah

    DTIC Science & Technology

    2013-08-08

    FA8201-09-D-0002 Facilities, Hill Air Force Base, Utah 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) Klein, Randal 5d...PERFORMING ORGANIZATION REPORT NUMBER Streamline Consulting, LLC 1713 N. Sweetwater Lane Farmington, Utah 84025...proposes to construct new training facilities at Hill Air Force Base, Utah . The findings of this EA indicate that the proposed action would not have

  20. Numerical aerodynamic simulation facility preliminary study: Executive study

    NASA Technical Reports Server (NTRS)

    1977-01-01

    A computing system was designed with the capability of providing an effective throughput of one billion floating point operations per second for three dimensional Navier-Stokes codes. The methodology used in defining the baseline design, and the major elements of the numerical aerodynamic simulation facility are described.

  1. Exploring the elements of narrative that emerge in the interactions between an 8-year-old child who uses an AAC device and her teacher.

    PubMed

    Soto, Gloria; Hartmann, Elizabeth; Wilkins, David P

    2006-12-01

    Narrative abilities have been identified as a link to successful school achievement and, in particular, to the acquisition of literacy. Children who use AAC may be at risk of impaired narrative facility due to the differences in their language learning experiences, limitation of their AAC systems, and limitations from constrained access to physical and social environments. In this study, the elements of narrative that emerged in the interactions between an 8-year-old child who used an AAC device and her teacher are described. This assessment was achieved through use of the Narrative Assessment Profile (Bliss, McCabe, & Miranda, 1998) in the context of five tasks designed to elicit a spectrum of narrative features. Results indicate that the interactions between the child and her teacher made it difficult to assess whether or not the child had control of certain features of narrative. From a purely structural analysis, most narrative discourse dimensions appeared to be severely compromised and therefore in need of immediate intervention. Discussion includes aspects of narrative intervention and suggested topics for further research.

  2. Can facility delivery reduce the risk of intrapartum complications-related perinatal mortality? Findings from a cohort study.

    PubMed

    Khanam, Rasheda; Baqui, Abdullah H; Syed, Mamun Ibne Moin; Harrison, Meagan; Begum, Nazma; Quaiyum, Abdul; Saha, Samir K; Ahmed, Saifuddin

    2018-06-01

    Intrapartum complications increase the risk of perinatal deaths. However, population-based data from developing countries assessing the contribution of intrapartum complications to perinatal deaths is scarce. Using data from a cohort of pregnant women followed between 2011 and 2013 in Bangladesh, this study examined the rate and types of intrapartum complications, the association of intrapartum complications with perinatal mortality, and if facility delivery modified the risk of intrapartum-related perinatal deaths. Trained community health workers (CHWs) made two-monthly home visits to identify pregnant women, visited them twice during pregnancy and 10 times in the first two months postpartum. During prenatal visits, CHWs collected data on women's prior obstetric history, socio-demographic status, and complications during pregnancy. They collected data on intrapartum complications, delivery care, and pregnancy outcome during the first postnatal visit within 7 days of delivery. We examined the association of intrapartum complications and facility delivery with perinatal mortality by estimating odds ratios (OR) and 95% confidence intervals (CI) adjusting for covariates using multivariable logistic regression analysis. The overall facility delivery rate was low (3922/24 271; 16.2%). Any intrapartum complications among pregnant women were 20.9% (5,061/24,271) and perinatal mortality was 64.7 per 1000 birth. Compared to women who delivered at home, the risk of perinatal mortality was 2.4 times higher (OR = 2.40; 95% CI = 2.08-2.76) when delivered in a public health facility and 1.3 times higher (OR = 1.32, 95% CI = 1.06-1.64) when delivered in a private health facility. Compared to women who had no intrapartum complications and delivered at home, women with intrapartum complications who delivered at home had a substantially higher risk of perinatal mortality (OR = 3.45; 95% CI = 3.04-3.91). Compared to women with intrapartum complications who delivered at home, the risk of perinatal mortality among women with intrapartum complications was 43.0% lower for women who delivered in a public health facility (OR = 0.57; 95% CI = 0.42-0.78) and 58.0% lower when delivered in a private health facility (OR = 0.42; 95% CI = 0.28-0.63). Maternal health programs need to promote timely recognition of intrapartum complications and delivery in health facilities to improve perinatal outcomes, particularly in populations where overall facility delivery rates are low. The differential risk between public and private health facilities may be due to differences in quality of care. Efforts should be made to improve the quality of care in all health facilities.

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mathews, M.A.; Bowman, H.R.; Huang, L., H.

    A low radioactivity calibration facility has been constructed at the Nevada Test Site (NTS). This facility has four calibration models of natural stone that are 3 ft in diameter and 6 ft long, with a 12 in. cored borehole in the center of each model and a lead-shielded run pipe below each model. These models have been analyzed by laboratory natural gamma ray spectroscopy (NGRS) and neutron activation analysis (NAA) for their K, U, and Th content. Also, 42 other elements were analyzed in the NAA. The /sup 222/Rn emanation data were collected. Calibrating the spectral gamma tool in thismore » low radioactivity calibration facility allows the spectral gamma log to accurately aid in the recognition and mapping of subsurface stratigraphic units and alteration features associated with unusual concentrations of these radioactive elements, such as clay-rich zones.« less

  4. Walla Walla River Fish Passage Operations Project : Annual Progress Report October 2007 - September 2008.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bronson, James P.; Duke, Bill; Loffink, Ken

    2008-12-30

    In the late 1990s, the Confederated Tribes of the Umatilla Indian Reservation, Oregon Department of Fish and Wildlife, and Washington Department of Fish and Wildlife, along with many other agencies, began implementing fisheries restoration activities in the Walla Walla Basin. An integral part of these efforts is to alleviate the inadequate fish migration conditions in the basin. Migration concerns are being addressed by removing diversion structures, constructing fish passage facilities, implementing minimum instream flow requirements, and providing trap and haul efforts when needed. The objective of the Walla Walla River Fish Passage Operations Project is to increase the survival ofmore » migrating adult and juvenile salmonids in the Walla Walla River basin. The project is responsible for coordinating operation and maintenance of ladders, screen sites, bypasses, trap facilities, and transportation equipment. In addition, the project provides technical input on passage and trapping facility design, operation, and criteria. Operation of the various passage facilities and passage criteria guidelines are outlined in an annual operations plan that the project develops. Beginning in March of 2007, two work elements from the Walla Walla Fish Passage Operations Project were transferred to other projects. The work element Enumeration of Adult Migration at Nursery Bridge Dam is now conducted under the Walla Walla Basin Natural Production Monitoring and Evaluation Project and the work element Provide Transportation Assistance is conducted under the Umatilla Satellite Facilities Operation and Maintenance Project. Details of these activities can be found in those project's respective annual reports.« less

  5. How Common is Common Use Facilities at Airports

    NASA Astrophysics Data System (ADS)

    Barbeau, Addison D.

    This study looked at common use airports across the country and at the implementation of common use facailities at airports. Common use consists of several elements that maybe installed at an airport. One of the elements is the self-service kiosks that allow passengers to have a faster check-in process, therefore moving them more quickly within the airport. Another element is signage and the incorporation of each airline's logo. Another aspect of common useis an airport regaining control of terminal gates by reducing the number of gates that are exclusively leased to a specific air carrier. This research focused on the current state of the common use facilities across the United States and examines the advantages and disadvantages of this approach. The research entailed interviews with personnel at a wide range of airports and found that each airport is in a different stage of implementation; some have fully implemented the common use concept while others are in the beginning stages of implementation. The questions were tailored to determine what the advantages and disadvantages are of a common use facility. The most common advantages reported included flexibility and cost. In the commom use system the airport reserves the right to move any airline to a different gate at any time for any reason. In turn, this helps reduce gates delays at that facility. For the airports that were interviewed no major disadvantages were reported. One down side of common use facilities for the airport involved is the major capital cost that is required to move to a common use system.

  6. Elements of Conjunctive Use Water Supply.

    DTIC Science & Technology

    1988-03-01

    180 ENVIRONMENTAL EFFECTS ............ oee-eesessese..........182 EFFECTS OF FACILITIES...184 EFFECTS OF APPLICATION OF WATER .................. 191 EFFECTS OF GROUNDWATER PUMPING ........................ 197 AIR QUALITY, NOISE...those involved in conjunctive use planning to more effectively and quickly focus on the necessary tasks. The major elements are described and important

  7. 47 CFR 69.307 - General support facilities.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ....307 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) COMMON CARRIER SERVICES (CONTINUED... computer investment used in the provision of the Line Information Database sub-element at § 69.120(b) shall be assigned to that sub-element. (b) General purpose computer investment used in the provision of the...

  8. 47 CFR 69.307 - General support facilities.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ....307 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) COMMON CARRIER SERVICES (CONTINUED... computer investment used in the provision of the Line Information Database sub-element at § 69.120(b) shall be assigned to that sub-element. (b) General purpose computer investment used in the provision of the...

  9. 47 CFR 69.307 - General support facilities.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ....307 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) COMMON CARRIER SERVICES (CONTINUED... computer investment used in the provision of the Line Information Database sub-element at § 69.120(b) shall be assigned to that sub-element. (b) General purpose computer investment used in the provision of the...

  10. 47 CFR 69.307 - General support facilities.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ....307 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) COMMON CARRIER SERVICES (CONTINUED... computer investment used in the provision of the Line Information Database sub-element at § 69.120(b) shall be assigned to that sub-element. (b) General purpose computer investment used in the provision of the...

  11. 47 CFR 69.307 - General support facilities.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ....307 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) COMMON CARRIER SERVICES (CONTINUED... computer investment used in the provision of the Line Information Database sub-element at § 69.120(b) shall be assigned to that sub-element. (b) General purpose computer investment used in the provision of the...

  12. Geostationary platform study: Advanced ESGP/evolutionary SSF accommodation study

    NASA Technical Reports Server (NTRS)

    1990-01-01

    The implications on the evolutionary space station of accommodating geosynchronous Earth Orbit (GEO) facilities including unmanned satellites and platforms, manned elements, and transportation and servicing vehicles/elements. The latest existing definitions of typical unmanned GEO facilities and transportation and servicing vehicles/elements are utilized. The physical design, functional design, and operations implications at the space station are determined. Various concepts of the space station from past studies are utilized ranging from the IOC Multifunction Space Station to a branched transportation node space station, and the implications of the accommodation the GEO infrastructure of each type are assessed. Where possible, parametric data are provided to show the implications of variations in sizes and quantities of elements, launch rates, crew sizes, etc. The use of advanced automation, robotics equipment, and an efficient mix of manned/automated support for accomplishing necessary activities at the space station are identified and assessed. The products of this study are configuration sketches, resource requirements, trade studies, and parametric data.

  13. Bioaerosol releases from compost facilities: Evaluating passive and active source terms at a green waste facility for improved risk assessments

    NASA Astrophysics Data System (ADS)

    Taha, M. P. M.; Drew, G. H.; Longhurst, P. J.; Smith, R.; Pollard, S. J. T.

    The passive and active release of bioaerosols during green waste composting, measured at source is reported for a commercial composting facility in South East (SE) England as part of a research programme focused on improving risk assessments at composting facilities. Aspergillus fumigatus and actinomycetes concentrations of 9.8-36.8×10 6 and 18.9-36.0×10 6 cfu m -3, respectively, measured during the active turning of green waste compost, were typically 3-log higher than previously reported concentrations from static compost windrows. Source depletion curves constructed for A. fumigatus during compost turning and modelled using SCREEN3 suggest that bioaerosol concentrations could reduce to background concentrations of 10 3 cfu m -3 within 100 m of this site. Authentic source term data produced from this study will help to refine the risk assessment methodologies that support improved permitting of compost facilities.

  14. Energy Conscious Design: Educational Facilities. [Brief No.] 1.

    ERIC Educational Resources Information Center

    American Inst. of Architects, Washington, DC.

    An energy task group of the American Institute of Architects discusses design features and options that educational facility designers can use to create an energy efficient school building. Design elements cover the building envelope, energy storage system, hydronic heating/cooling systems, solar energy collection, building orientation and shape,…

  15. Battery Second Use for Plug-In Electric Vehicles Analysis | Transportation

    Science.gov Websites

    batteries, and how much will it cost? NREL's investigation found that regional repurposing facilities . As technician labor is the primary cost element of such an operation, repurposing facilities are /kilowatt-hour (kWh)-nameplate. NREL's repurposing cost calculator is available freely for download

  16. Senator Doug Jones (D-AL) Tour of MSFC Facilities

    NASA Image and Video Library

    2018-02-22

    Senator Doug Jones (D-AL.) and wife, Louise, tour Marshall Space Flight facilities. Steve Doering, manager, Stages Element, Space Launch System (SLS) program at MSFC, also tour the Payload Operations Integration Center (POIC) where Marshall controllers oversee stowage requirements aboard the International Space Station (ISS) as well as scientific experiments.

  17. Profile of hepatitis B and C virus infection in prisoners in Lubuk Pakam correctional facilities

    NASA Astrophysics Data System (ADS)

    Rey, I.; Saragih, R. H.; Effendi-YS, R.; Sembiring, J.; Siregar, G. A.; Zain, L. H.

    2018-03-01

    Prisoners in correctional facilities are predisposed to chronic viral infections because of their high-risk behaviors or unsafe lifestyle. The economic and public health burden of chronic hepatitis B and C and its sequelae need to be addressed, such as by finding the risk factors and therefore reducing the spread of HCV and HBV infection in prisons. This study aimed to see the profile of Hepatitis B and C Virus Infection in prisoners in Lubuk Pakam Correctional Facilities. This cross-sectional study was in Lubuk Pakam Correctional Facilities in 2016. From 1114 prisoners in Lubuk Pakam correctional facility, we randomly examined 120 prisoners for HBV and HCV serology markers. From 120 prisoners, six prisoners were HBV positive, 21 prisoners were HCV positive and one prisoner positive for both HCV and HBV infection. The most common risk factors for prisoners getting HBV infection are tattoos and free sex (36.4% and 36.4%, respectively). The most common risk factors for HCV infection in prisoners are tattoos and free sex (40% and 35%, respectively).

  18. Space-Based Space Surveillance Logistics Case Study: A Qualitative Product Support Element Analysis

    DTIC Science & Technology

    2017-12-01

    Facilities and Infrastructure. Product Support Management and Design Interface are also covered, but only in a general manner. Conclusions from the study...core analysis, with the overarching two elements ( Design Interface and Product Support Management) mentioned briefly. G. THESIS STATEMENT This...were implemented. The two overarching elements of Product Support Management and Design Interface will be discussed briefly in the findings section

  19. Trace element partitioning in ashes from boilers firing pure wood or mixtures of solid waste with respect to fuel composition, chlorine content and temperature

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Saqib, Naeem, E-mail: naeem.saqib@oru.se; Bäckström, Mattias, E-mail: mattias.backstrom@oru.se

    Highlights: • Different solids waste incineration is discussed in grate fired and fluidized bed boilers. • We explained waste composition, temperature and chlorine effects on metal partitioning. • Excessive chlorine content can change oxide to chloride equilibrium partitioning the trace elements in fly ash. • Volatility increases with temperature due to increase in vapor pressure of metals and compounds. • In Fluidized bed boiler, most metals find themselves in fly ash, especially for wood incineration. - Abstract: Trace element partitioning in solid waste (household waste, industrial waste, waste wood chips and waste mixtures) incineration residues was investigated. Samples of flymore » ash and bottom ash were collected from six incineration facilities across Sweden including two grate fired and four fluidized bed incinerators, to have a variation in the input fuel composition (from pure biofuel to mixture of waste) and different temperature boiler conditions. As trace element concentrations in the input waste at the same facilities have already been analyzed, the present study focuses on the concentration of trace elements in the waste fuel, their distribution in the incineration residues with respect to chlorine content of waste and combustion temperature. Results indicate that Zn, Cu and Pb are dominating trace elements in the waste fuel. Highly volatile elements mercury and cadmium are mainly found in fly ash in all cases; 2/3 of lead also end up in fly ash while Zn, As and Sb show a large variation in distribution with most of them residing in the fly ash. Lithophilic elements such as copper and chromium are mainly found in bottom ash from grate fired facilities while partition mostly into fly ash from fluidized bed incinerators, especially for plants fuelled by waste wood or ordinary wood chips. There is no specific correlation between input concentration of an element in the waste fuel and fraction partitioned to fly ash. Temperature and chlorine content have significant effects on partitioning characteristics by increasing the formation and vaporization of highly volatile metal chlorides. Zinc and cadmium concentrations in fly ash increase with the incineration temperature.« less

  20. Association between access to accelerated partial breast irradiation and use of adjuvant radiotherapy.

    PubMed

    Wang, Elyn H; Park, Henry S; Rutter, Charles E; Gross, Cary P; Soulos, Pamela R; Yu, James B; Evans, Suzanne B

    2017-02-01

    The current study was performed to determine whether access to facilities performing accelerated partial breast irradiation (APBI) is associated with differences in the use of adjuvant radiotherapy (RT). Using the National Cancer Data Base, the authors performed a retrospective study of women aged ≥50 years who were diagnosed with early-stage breast cancer between 2004 and 2013 and treated with breast-conserving surgery (BCS). Facilities performing APBI in ≥10% of their eligible patients within a given year were defined as APBI facilities whereas those not performing APBI were defined as non-APBI facilities. All other facilities were excluded. The authors identified independent factors associated with RT use using multivariable logistic regression with clustering in the overall sample as well as in subsets of patients with standard-risk invasive cancer, low-risk invasive cancer, and ductal carcinoma in situ. Among 222,544 patients, 76.6% underwent BCS plus RT and 23.4% underwent BCS alone. The likelihood of RT receipt in the overall sample did not appear to differ significantly between APBI and non-APBI facilities (adjusted odds ratio [AOR], 1.02; P = .61). Subgroup multivariable analysis demonstrated that among patients with standard-risk invasive cancer, there was no association between evaluation at an APBI facility and receipt of RT (AOR, 0.98; P = .69). However, patients with low-risk invasive cancer were found to be significantly more likely to receive RT (54.4% vs 59.5%; AOR, 1.22 [P<.001]), whereas patients with ductal carcinoma in situ were less likely to receive RT (56.9% vs 55.3%; AOR, 0.89 [P = .04]) at APBI facilities. Patients who were eligible for observation were more likely to receive RT in APBI facilities but no difference was observed among patients with standard-risk invasive cancer who would most benefit from RT. Cancer 2017;123:502-511. © 2016 American Cancer Society. © 2016 American Cancer Society.

  1. Beyond Ebola treatment units: severe infection temporary treatment units as an essential element of Ebola case management during an outbreak.

    PubMed

    Janke, Christian; Heim, Katrin Moira; Steiner, Florian; Massaquoi, Moses; Gbanya, Miatta Zenabu; Frey, Claudia; Froeschl, Guenter

    2017-02-06

    In the course of the Ebola outbreak in West Africa that was witnessed since early 2014, the response mechanisms showed deficits in terms of timeliness, volume and adequacy. The authors were deployed in the Ebola campaign in the West African country Liberia, where by September 2014 the changing epidemiological pattern made reconsiderations of guidelines and adopted procedures necessary. A temporary facility set up as a conventional Ebola Treatment Unit in the Liberian capital Monrovia was re-dedicated into a Severe Infections Temporary Treatment Unit. This facility allowed for stratification based on the nosocomial risk of exposure to Ebola virus for a growing subgroup of admitted patients that in the end would turn out as Ebola negative cases. At the same time, adequate diagnostic measures and treatment for the non-Ebola conditions of these patients could be provided without compromising work safety of the employed staff. The key elements of the new unit comprised a Suspect Cases Area similar to that of conventional Ebola treatment units for newly arriving patients, an Unlikely Cases Area for patients with a first negative Ebola PCR result, and a Confirmed Negative Cases Area for patients in whom Ebola could be ruled out. The authors, comprising representatives of the Liberian Ministry of Health and Social Welfare, as well as infectious disease specialists from the German Ebola Task Force are presenting key features of the adapted concept, and are highlighting its relevance in raising acceptance for outbreak counter-measures within the population at stake.

  2. Comparative research on NIMBY risk acceptability between Chinese and Japanese college students.

    PubMed

    Wu, Yunqing; Zhai, Guofang; Li, Shasha; Ren, Chongqiang; Tsuchida, Shoji

    2014-10-01

    Along with the progressive acceleration of urbanization, the need to identify potentially troublesome "Not In My Back Yard" (NIMBY) facilities in the city is inevitable. To resolve NIMBY conflict, it is important to know people's NIMBY risk acceptability for these facilities. A questionnaire survey was used among Chinese and Japanese college students to identify NIMBY risk acceptability. LISREL was used to construct a structural equation model to analyze the difference in NIMBY risk acceptability between the Chinese and Japanese college students. Factors that may affect NIMBY risk acceptability were analyzed: "perceiving utility," "perceiving risk," "trust in government," "reasonable compensation," and "procedural justice." The findings show that Japanese students' concerns were greater than Chinese students' concerns. Perceiving utility and perceiving risk were the most important factors that affect people's NIMBY risk acceptability, followed by procedural justice, trust in government, and reasonable compensation. There is a difference between the different cultural backgrounds in confronting the risk: Chinese students focus more on the reputation and value of real estate, while Japanese students pay more attention to environmental pollution and damage to health. Furthermore, cultural influences play a role in students' risk perception. To improve the risk acceptability for NIMBY facilities and provide a basis for resolving NIMBY conflicts, it is necessary to ensure the benefits of the NIMBY facility while reducing environmental pollution. The findings of this study may be of interest for policy makers and practitioners to devise future NIMBY strategies.

  3. Study on the flood simulation techniques for estimation of health risk in Dhaka city, Bangladesh

    NASA Astrophysics Data System (ADS)

    Hashimoto, M.; Suetsugi, T.; Sunada, K.; ICRE

    2011-12-01

    Although some studies have been carried out on the spread of infectious disease with the flooding, the relation between flooding and the infectious expansion has not been clarified yet. The improvement of the calculation precision of inundation and its relation with the infectious disease, surveyed epidemiologically, are therefore investigated in a case study in Dhaka city, Bangladesh. The inundation was computed using a flood simulation model that is numerical 2D-model. The "sensitivity to inundation" of hydraulic factors such as drainage channel, dike, and the building occupied ratio was examined because of the lack of digital data set related to flood simulation. Each element in the flood simulation model was incorporated progressively and results were compared with the calculation result as inspection materials by the inundation classification from the existing study (Mollah et al., 2007). The results show that the influences by ''dyke'' and "drainage channel" factors are remarkable to water level near each facility. The inundation level and duration have influence on wide areas when "building occupied ratio" is also considered. The correlation between maximum inundation depth and health risk (DALY, Mortality, Morbidity) was found, but the validation of the inundation model for this case has not been performed yet. The flood simulation model needs to be validated by observed inundation depth. The drainage facilities such as sewer network or the pumping system will be also considered in the further research to improve the precision of the inundation model.

  4. Conceptual design of the MHD Engineering Test Facility

    NASA Technical Reports Server (NTRS)

    Bents, D. J.; Bercaw, R. W.; Burkhart, J. A.; Mroz, T. S.; Rigo, H. S.; Pearson, C. V.; Warinner, D. K.; Hatch, A. M.; Borden, M.; Giza, D. A.

    1981-01-01

    The reference conceptual design of the MHD engineering test facility, a prototype 200 MWe coal-fired electric generating plant designed to demonstrate the commerical feasibility of open cycle MHD is summarized. Main elements of the design are identified and explained, and the rationale behind them is reviewed. Major systems and plant facilities are listed and discussed. Construction cost and schedule estimates are included and the engineering issues that should be reexamined are identified.

  5. Internationalization of the Space Station

    NASA Technical Reports Server (NTRS)

    Lottmann, R. V.

    1985-01-01

    Attention is given to the NASA Space Station system elements whose production is under consideration by potential foreign partners. The ESA's Columbus Program declaration encompasses studies of pressurized modules, unmanned payload carriers, and ground support facilities. Canada has expressed interest in construction and servicing facilities, solar arrays, and remote sensing facilities. Japanese studies concern a multipurpose experimental module concept. Each of these foreign investments would expand Space Station capabilities and lay the groundwork for long term partnerships.

  6. Holifield Heavy-Ion Research Facility at Oak Ridge

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jones, C.M.

    1977-01-01

    A new heavy-ion accelerator facility is now under construction at the Oak Ridge National Laboratory. A brief description of the scope and schedule of this project is given, and the new large tandem accelerator, which will be a major element of the facility is discussed in some detail. Several studies which have been made or are in progress in Oak Ridge in preparation for operation of the tandem accelerator are briefly described.

  7. Assessment of Colorado Department of Transportation rest areas for sustainability improvements and highway corridors and facilities for alternative energy use

    DOT National Transportation Integrated Search

    2011-03-01

    The research project focused on two sustainability based elements associated with the Colorado Department of Transportation : (CDOT) Maintenance operations, namely rest areas and right-of-way (ROW) utilization. For the first element, a sustainability...

  8. Sports Fields: A Manual for Design Construction and Maintenance.

    ERIC Educational Resources Information Center

    Puhalla, Jim; Krans, Jeff; Goatley, Mike

    Comprehensive technical reference information is provided for those responsible for the design, construction, renovation, or maintenance of sports grounds. Chapters illustrate specific design elements of all popular sports facilities, and explain how those elements are integrated in a successful project; explore commonly encountered sports field…

  9. Spatial Distribution and Fuzzy Health Risk Assessment of Trace Elements in Surface Water from Honghu Lake.

    PubMed

    Li, Fei; Qiu, Zhenzhen; Zhang, Jingdong; Liu, Chaoyang; Cai, Ying; Xiao, Minsi

    2017-09-04

    Previous studies revealed that Honghu Lake was polluted by trace elements due to anthropogenic activities. This study investigated the spatial distribution of trace elements in Honghu Lake, and identified the major pollutants and control areas based on the fuzzy health risk assessment at screening level. The mean total content of trace elements in surface water decreased in the order of Zn (18.04 μg/L) > Pb (3.42 μg/L) > Cu (3.09 μg/L) > Cr (1.63 μg/L) > As (0.99 μg/L) > Cd (0.14 μg/L), within limits of Drinking Water Guidelines. The results of fuzzy health risk assessment indicated that there was no obvious non-carcinogenic risk to human health, while carcinogenic risk was observed in descending order of As > Cr > Cd > Pb. As was regarded to have the highest carcinogenic risk among selected trace elements because it generally accounted for 64% of integrated carcinogenic risk. Potential carcinogenic risk of trace elements in each sampling site was approximately at medium risk level (10 -5 to 10 -4 ). The areas in the south (S4, S13, and S16) and northeast (S8, S18, and S19) of Honghu Lake were regarded as the risk priority control areas. However, the corresponding maximum memberships of integrated carcinogenic risk in S1, S3, S10-S13, S15, and S18 were of relatively low credibility (50-60%), and may mislead the decision-makers in identifying the risk priority areas. Results of fuzzy assessment presented the subordinate grade and corresponding reliability of risk, and provided more full-scale results for decision-makers, which made up for the deficiency of certainty assessment to a certain extent.

  10. Spatial Distribution and Fuzzy Health Risk Assessment of Trace Elements in Surface Water from Honghu Lake

    PubMed Central

    Qiu, Zhenzhen; Zhang, Jingdong; Liu, Chaoyang; Cai, Ying; Xiao, Minsi

    2017-01-01

    Previous studies revealed that Honghu Lake was polluted by trace elements due to anthropogenic activities. This study investigated the spatial distribution of trace elements in Honghu Lake, and identified the major pollutants and control areas based on the fuzzy health risk assessment at screening level. The mean total content of trace elements in surface water decreased in the order of Zn (18.04 μg/L) > Pb (3.42 μg/L) > Cu (3.09 μg/L) > Cr (1.63 μg/L) > As (0.99 μg/L) > Cd (0.14 μg/L), within limits of Drinking Water Guidelines. The results of fuzzy health risk assessment indicated that there was no obvious non-carcinogenic risk to human health, while carcinogenic risk was observed in descending order of As > Cr > Cd > Pb. As was regarded to have the highest carcinogenic risk among selected trace elements because it generally accounted for 64% of integrated carcinogenic risk. Potential carcinogenic risk of trace elements in each sampling site was approximately at medium risk level (10−5 to 10−4). The areas in the south (S4, S13, and S16) and northeast (S8, S18, and S19) of Honghu Lake were regarded as the risk priority control areas. However, the corresponding maximum memberships of integrated carcinogenic risk in S1, S3, S10–S13, S15, and S18 were of relatively low credibility (50–60%), and may mislead the decision-makers in identifying the risk priority areas. Results of fuzzy assessment presented the subordinate grade and corresponding reliability of risk, and provided more full-scale results for decision-makers, which made up for the deficiency of certainty assessment to a certain extent. PMID:28869576

  11. Risk Factors for Pressure Ulcers Including Suspected Deep Tissue Injury in Nursing Home Facility Residents: Analysis of National Minimum Data Set 3.0.

    PubMed

    Ahn, Hyochol; Cowan, Linda; Garvan, Cynthia; Lyon, Debra; Stechmiller, Joyce

    2016-04-01

    To provide information on risk factors associated with pressure ulcers (PrUs), including suspected deep tissue injury (sDTI), in nursing home residents in the United States. This continuing education activity is intended for physicians and nurses with an interest in skin and wound care. After participating in this educational activity, the participant should be better able to:1. Examine the literature related to risk factors for the development of PrUs.2. Compare risk factors associated with the prevalence of PrUs and sDTI from the revised Minimum Data Set 3.0 2012 using a modified Defloor's conceptual model of PrUs as a theoretical framework. This study aims to characterize and compare risk factors associated with pressure ulcers (PrUs), including suspected deep tissue injury (sDTI), in nursing home (NH) residents in the United States. Secondary analysis of the 2012 Minimum Data Set (MDS 3.0). Medicare- or Medicaid-certified NHs in the United States. Nursing home residents (n = 2,936,146) 18 years or older with complete PrU data, who received comprehensive assessments from January to December 2012. Pressure ulcer by stage was the outcome variable. Explanatory variables (age, gender, race and ethnicity, body mass index, skin integrity, system failure, disease, infection, mobility, and cognition) from the MDS 3.0 were aligned with the 4 elements of Defloor's conceptual model: compressive forces, shearing forces, tissue tolerance for pressure, and tissue tolerance for oxygen. Of 2,936,146 NH residents who had complete data for PrU, 89.9% had no PrU; 8.4% had a Stage 2, 3, or 4 or unstagable PrU; and 1.7% had an sDTI. The MDS variables corresponding to the 4 elements of Defloor's model were significantly predictive of both PrU and sDTI. Black residents had the highest risk of any-stage PrU, and Hispanic residents had the highest risk of sDTI. Skin integrity, system failure, infection, and disease risk factors had larger effect sizes for sDTI than for other PrU stages. The MDS data support Defloor's model and inform clinicians, educators, researchers, and policymakers on risk factors associated with PrUs and sDTI in NH residents in the United States participating in Medicare and Medicaid.

  12. Residential proximity to industrial combustion facilities and risk of non-Hodgkin lymphoma: a case–control study

    PubMed Central

    2013-01-01

    Background Residence near municipal solid waste incinerators, a major historical source of dioxin emissions, has been associated with increased risk of non-Hodgkin lymphoma (NHL) in European studies. The aim of our study was to evaluate residence near industrial combustion facilities and estimates of dioxin emissions in relation to NHL risk in the United States. Methods We conducted a population-based case–control study of NHL (1998–2000) in four National Cancer Institute-Surveillance Epidemiology and End Results centers (Detroit, Iowa, Los Angeles, Seattle). Residential histories 15 years before diagnosis (similar date for controls) were linked to an Environmental Protection Agency database of dioxin-emitting facilities for 969 cases and 749 controls. We evaluated proximity (3 and 5 km) to 10 facility types that accounted for >85% of U.S. emissions and a distance-weighted average emission index (AEI [ng toxic equivalency quotient (TEQ)/year]). Results Proximity to any dioxin-emitting facility was not associated with NHL risk (3 km OR = 1.0, 95% CI 0.8-1.3). Risk was elevated for residence near cement kilns (5 km OR = 1.7, 95% CI 0.8-3.3; 3 km OR = 3.8, 95% CI 1.1-14.0) and reduced for residence near municipal solid waste incinerators (5 km OR = 0.5, 95% CI 0.3-0.9; 3 km OR = 0.3, 95% CI 0.1-1.4). The AEI was not associated with risk of NHL overall. Risk for marginal zone lymphoma was increased for the highest versus lowest quartile (5 km OR = 2.6, 95% CI 1.0-6.8; 3 km OR = 3.0, 95% CI 1.1-8.3). Conclusions Overall, we found no association with residential exposure to dioxins and NHL risk. However, findings for high emissions and marginal zone lymphoma and for specific facility types and all NHL provide some evidence of an association and deserve future study. PMID:23433489

  13. Integrated assessment of urban vulnerability and resilience. Case study: Targu Ocna town, Romania

    NASA Astrophysics Data System (ADS)

    Grozavu, Adrian; Bănică, Alexandru

    2015-04-01

    Vulnerability assessment frequently emphasizes the internal fragility of a system in relation to a given hazard, when compared to similar systems or to a reference standard. This internal fragility, either biophysical or structural, may affect the ability to predict, to prepare for and cope with or to recover from the manifestation of a risk phenomenon. Thus, the vulnerability is highly related to resilience and adaptability. There is no single methodology for vulnerability and resilience analysis, their assessment can only be made by identifying and integrating indicators which are compatible with the analysis level and the geographic, economic and social features of a certain area. An integrated model of evaluating vulnerability and resilience capacity is being proposed in this paper for Targu Ocna, a small mining settlement in the Eastern Carpathians of Romania, that became in the last years a tourist town and acts within the surrounding territory as a dynamic local pole. Methodologically, the following steps and operations were considered: identifying potential hazards, identifying elements at risk, identifying proper indicators and integrating them in order to evaluate the general vulnerability and resilience. The inventory of elements at risk (the number of people potentially affected, residential or other functionalities buildings, roads and other infrastructure elements etc.) was made based on General Urban Plan, topographic maps (scale 1:5000), ortophotos from 2003 and 2008 and field mapping and researches. Further on, several vulnerability indicators were identified and included within the analytical approach: dependency ratio, income, quality of the habitat and technical urban facilities, environment quality showing differentiated sensitivity. Issues such as preparedness and preventive measures (priority areas within the risk prevention plans), coping ability (networks' geometry and connectivity, emergency utilities and services accessibility) and the recovering capacity (the time needed to reestablish functions after a disastrous event) were also taken into account. The selected indicators were mathematically processed (standardized and normalized) in order to maximize their relevance and to unitary express the results in the spread 0-1. Then a grid with a cell size of 100 x 100 m was created in order to spatialize vulnerability indicators, that were calculated as the average vulnerability of the exposed elements in each cell. All identified indicators have been processed within a cluster analysis that permitted the identification of similar areas in terms of vulnerabilities. Finally, a general index was obtained by the integration of all vulnerability factors in an equation based on the geometric mean. The results of the study could provide a reference basis to substantiate local correctly prioritized decisions for reducing vulnerability by mitigation and adaptation measures in order to avoid significant damages when risks materialise.

  14. Development of risk-based decision methodology for facility design.

    DOT National Transportation Integrated Search

    2014-06-01

    This report develops a methodology for CDOT to use in the risk analysis of various types of facilities and provides : illustrative examples for the use of the proposed framework. An overview of the current practices and applications to : illustrate t...

  15. Earthquakes and building design: a primer for the laboratory animal professional.

    PubMed

    Vogelweid, Catherine M; Hill, James B; Shea, Robert A; Johnson, Daniel B

    2005-01-01

    Earthquakes can occur in most regions of the United States, so it might be necessary to reinforce vulnerable animal facilities to better protect research animals during these unpredictable events. A risk analysis should include an evaluation of the seismic hazard risk at the proposed building site balanced against the estimated consequences of losses. Risk analysis can help in better justifying and recommending to building owners the costs of incorporating additional seismic reinforcements. The planning team needs to specify the level of post-earthquake building function that is desired in the facility, and then design the facility to it.

  16. Integration of Biosafety into Core Facility Management

    PubMed Central

    Fontes, Benjamin

    2013-01-01

    This presentation will discuss the implementation of biosafety policies for small, medium and large core laboratories with primary shared objectives of ensuring the control of biohazards to protect core facility operators and assure conformity with applicable state and federal policies, standards and guidelines. Of paramount importance is the educational process to inform core laboratories of biosafety principles and policies and to illustrate the technology and process pathways of the core laboratory for biosafety professionals. Elevating awareness of biohazards and the biosafety regulatory landscape among core facility operators is essential for the establishment of a framework for both project and material risk assessment. The goal of the biohazard risk assessment process is to identify the biohazard risk management parameters to conduct the procedure safely and in compliance with applicable regulations. An evaluation of the containment, protective equipment and work practices for the procedure for the level of risk identified is facilitated by the establishment of a core facility registration form for work with biohazards and other biological materials with potential risk. The final step in the biocontainment process is the assumption of Principal Investigator role with full responsibility for the structure of the site-specific biosafety program plan by core facility leadership. The presentation will provide example biohazard protocol reviews and accompanying containment measures for core laboratories at Yale University.

  17. Initial Operation of the Nuclear Thermal Rocket Element Environmental Simulator

    NASA Technical Reports Server (NTRS)

    Emrich, William J., Jr.; Pearson, J. Boise; Schoenfeld, Michael P.

    2015-01-01

    The Nuclear Thermal Rocket Element Environmental Simulator (NTREES) facility is designed to perform realistic non-nuclear testing of nuclear thermal rocket (NTR) fuel elements and fuel materials. Although the NTREES facility cannot mimic the neutron and gamma environment of an operating NTR, it can simulate the thermal hydraulic environment within an NTR fuel element to provide critical information on material performance and compatibility. The NTREES facility has recently been upgraded such that the power capabilities of the facility have been increased significantly. At its present 1.2 MW power level, more prototypical fuel element temperatures nay now be reached. The new 1.2 MW induction heater consists of three physical units consisting of a transformer, rectifier, and inverter. This multiunit arrangement facilitated increasing the flexibility of the induction heater by more easily allowing variable frequency operation. Frequency ranges between 20 and 60 kHz can accommodated in the new induction heater allowing more representative power distributions to be generated within the test elements. The water cooling system was also upgraded to so as to be capable of removing 100% of the heat generated during testing In this new higher power configuration, NTREES will be capable of testing fuel elements and fuel materials at near-prototypic power densities. As checkout testing progressed and as higher power levels were achieved, several design deficiencies were discovered and fixed. Most of these design deficiencies were related to stray RF energy causing various components to encounter unexpected heating. Copper shielding around these components largely eliminated these problems. Other problems encountered involved unexpected movement in the coil due to electromagnetic forces and electrical arcing between the coil and a dummy test article. The coil movement and arcing which were encountered during the checkout testing effectively destroyed the induction coil in use at the time and resulted in NTREES being out of commission for a couple of months while a new stronger coil was procured. The new coil includes several additional pieces of support structure to prevent coil movement in the future. In addition, new insulating test article support components have been fabricated to prevent unexpected arcing to the test articles. Additional activities are also now underway to address ways in which the radial temperature profiles across test articles may be controlled such that they are more prototypical of what they would encounter in an operating nuclear engine. The causes of the temperature distribution problem are twofold. First, the fuel element test article is isolated in NTREES as opposed to being in the midst of many other mostly identical fuel elements in a nuclear engine. As a result, the fuel element heat flux boundary conditions in NTREES are far from adiabatic as would normally be the case in a reactor. Second, induction heating skews the power distribution such that power is preferentially deposited near the outside of the fuel element. Nuclear heating, conversely, deposits its power much more uniformly throughout the fuel element. Current studies are now looking at various schemes to adjust the amount of thermal radiation emitted from the fuel element surface so as to essentially vary the thermal boundary conditions on the test article. It is hoped that by properly adjusting the thermal boundary conditions on the fuel element test article, it may be possible to substantially correct for the inappropriate radial power distributions resulting from the induction heating so as to yield a more nearly correct temperature distribution throughout the fuel element.

  18. The Effect of Dialysis Chains on Mortality among Patients Receiving Hemodialysis

    PubMed Central

    Zhang, Yi; Cotter, Dennis J; Thamer, Mae

    2011-01-01

    Objective To examine the association between dialysis facility chain affiliation and patient mortality. Study Setting Medicare dialysis population. Study Design Data from the United States Renal Data System (USRDS) were used to identify 3,601 free-standing dialysis facilities and 34,914 Medicare patients' incidence to end-stage renal disease (ESRD) in 2004. Mixed-effect regression models were used to estimate patient mortality by dialysis facility chain and profit status during the 2-year follow-up. Data Collection USRDS data were matched with facility, cost, and census data. Principle Findings Of the five largest dialysis chains, the lowest mortality risk was observed among patients dialyzed at nonprofit (NP) Chain 5 facilities. Compared with Chain 5, hazard ratios were 19 percent higher (95 percent CI 1.06–1.34) and 24 percent higher (95 percent CI 1.10–1.40) for patients dialyzed at for-profit (FP) Chain 1 and Chain 2 facilities, respectively. In addition, patients at FP facilities had a 13 percent higher risk of mortality than those in NP facilities (95 percent CI 1.06–1.22). Conclusions Large chain affiliation is an independent risk factor for ESRD mortality in the United States. Given the movement toward further consolidation of large FP chains, reasons behind the increase in mortality require scrutiny. PMID:21143480

  19. Element Material Exposure Experiment by EFFU

    NASA Technical Reports Server (NTRS)

    Hashimoto, Yoshihiro; Ito, Masaaki; Ishii, Masahiro

    1992-01-01

    The National Space Development Agency of Japan (NASDA) is planning to perform an 'Element Material Exposure Experiment' using the Exposed Facility Flyer Unit (EFFU). This paper presents an initial design of experiments proposed for this project by our company. The EFFU is installed on the Space Flyer Unit (SFU) as a partial model of the Space Station JEM exposed facility. The SFU is scheduled to be launched by H-2 rocket in January or February of 1994, then various tests will be performed for three months, on orbit of 500 km altitude, and it will be retrieved by the U.S. Space Shuttle and returned to the ground. The mission sequence is shown.

  20. A smart end-effector for assembly of space truss structures

    NASA Technical Reports Server (NTRS)

    Doggett, William R.; Rhodes, Marvin D.; Wise, Marion A.; Armistead, Maurice F.

    1992-01-01

    A unique facility, the Automated Structures Research Laboratory, is being used to investigate robotic assembly of truss structures. A special-purpose end-effector is used to assemble structural elements into an eight meter diameter structure. To expand the capabilities of the facility to include construction of structures with curved surfaces from straight structural elements of different lengths, a new end-effector has been designed and fabricated. This end-effector contains an integrated microprocessor to monitor actuator operations through sensor feedback. This paper provides an overview of the automated assembly tasks required by this end-effector and a description of the new end-effector's hardware and control software.

  1. Wakefield Computations for the CLIC PETS using the Parallel Finite Element Time-Domain Code T3P

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Candel, A; Kabel, A.; Lee, L.

    In recent years, SLAC's Advanced Computations Department (ACD) has developed the high-performance parallel 3D electromagnetic time-domain code, T3P, for simulations of wakefields and transients in complex accelerator structures. T3P is based on advanced higher-order Finite Element methods on unstructured grids with quadratic surface approximation. Optimized for large-scale parallel processing on leadership supercomputing facilities, T3P allows simulations of realistic 3D structures with unprecedented accuracy, aiding the design of the next generation of accelerator facilities. Applications to the Compact Linear Collider (CLIC) Power Extraction and Transfer Structure (PETS) are presented.

  2. Solar and Heliospheric Observatory (SOHO) Experimenters' Operations Facility (EOF)

    NASA Technical Reports Server (NTRS)

    Larduinat, Eliane; Potter, William

    1994-01-01

    This paper describes the SOHO Instrumenters' Operations Facility (EOF) project. The EOF is the element of the SOHO ground system at the Goddard Space Flight Center that provides the interface between the SOHO scientists and the other ground system elements. This paper first describes the development context of the SOHO EOF. It provides an overview of the SOHO mission within the International Solar-Terrestrial Physics (ISTP) project, and discusses the SOHO scientific objectives. The second part of this paper presents the implementation of the SOHO EOF, its innovative features, its possible applications to other missions, and its potential for use as part of a fully integrated ground control system.

  3. Factors Affecting Discharge to Home of Geriatric Intermediate Care Facility Residents in Japan.

    PubMed

    Morita, Kojiro; Ono, Sachiko; Ishimaru, Miho; Matsui, Hiroki; Naruse, Takashi; Yasunaga, Hideo

    2018-04-01

    To investigate factors associated with lower likelihood of discharge to home from geriatric intermediate care facilities in Japan. Retrospective cohort study. We used data from the nationwide long-term care (LTC) insurance claims database (April 2012-March 2014). Study participants were 342,758 individuals newly admitted to 3,459 geriatric intermediate care facilities during the study period. The primary outcome was discharge to home. We performed a multivariable competing-risk Cox regression with adjustment for resident-, facility-, and region-level characteristics. Resident level of care needs and several medical conditions were included as time-varying covariates. Death, admission to a hospital, and admission to another LTC facility were treated as competing risks. During the 2-year follow-up period, 19% of participants were discharged to home. In the multivariable competing-risk Cox regression, the following factors were significantly associated with lower likelihood of discharge to home: older age, higher level of care need, having several medical conditions, private ownership of the facility, more beds in the facility, and more LTC facility beds per 1,000 adults aged 65 and older in the region. Only 19% of residents were discharged to home. Our results are useful for policy-makers to promote discharge to home of older adults in geriatric intermediate care facilities. © 2018, Copyright the Authors Journal compilation © 2018, The American Geriatrics Society.

  4. The Zwicky Transient Facility Camera

    NASA Astrophysics Data System (ADS)

    Dekany, Richard; Smith, Roger M.; Belicki, Justin; Delacroix, Alexandre; Duggan, Gina; Feeney, Michael; Hale, David; Kaye, Stephen; Milburn, Jennifer; Murphy, Patrick; Porter, Michael; Reiley, Daniel J.; Riddle, Reed L.; Rodriguez, Hector; Bellm, Eric C.

    2016-08-01

    The Zwicky Transient Facility Camera (ZTFC) is a key element of the ZTF Observing System, the integrated system of optoelectromechanical instrumentation tasked to acquire the wide-field, high-cadence time-domain astronomical data at the heart of the Zwicky Transient Facility. The ZTFC consists of a compact cryostat with large vacuum window protecting a mosaic of 16 large, wafer-scale science CCDs and 4 smaller guide/focus CCDs, a sophisticated vacuum interface board which carries data as electrical signals out of the cryostat, an electromechanical window frame for securing externally inserted optical filter selections, and associated cryo-thermal/vacuum system support elements. The ZTFC provides an instantaneous 47 deg2 field of view, limited by primary mirror vignetting in its Schmidt telescope prime focus configuration. We report here on the design and performance of the ZTF CCD camera cryostat and report results from extensive Joule-Thompson cryocooler tests that may be of broad interest to the instrumentation community.

  5. Standardisation of the ion beam facility at Chandigarh cyclotron for simultaneous PIXE and PESA analysis

    NASA Astrophysics Data System (ADS)

    Verma, Shivcharan; Mohanty, Biraja P.; Singh, Karn P.; Kumar, Ashok

    2018-02-01

    The proton beam facility at variable energy cyclotron (VEC) Panjab University, Chandigarh, India is being used for Particle Induced X-ray Emission (PIXE) analysis of different environmental, biological and industrial samples. The PIXE method, however, does not provide any information of low Z elements like carbon, nitrogen, oxygen and fluorine. As a result of the increased need for rapid and multi-elemental analysis of biological and environmental samples, the PIXE facility was upgraded and standardized to facilitate simultaneous measurements using PIXE and Proton Elastic Scattering Analysis (PESA). Both PIXE and PESA techniques were calibrated and standardized individually. Finally, the set up was tested by carrying out simultaneous PIXE and PESA measurements using a 2 mm diameter proton beam of 2.7 MeV on few multilayered thin samples. The results obtained show excellent agreement between PIXE and PESA measurements and confirm adequate sensitivity and precision of the experimental set up.

  6. A large-scale computer facility for computational aerodynamics

    NASA Technical Reports Server (NTRS)

    Bailey, F. R.; Ballhaus, W. F., Jr.

    1985-01-01

    As a result of advances related to the combination of computer system technology and numerical modeling, computational aerodynamics has emerged as an essential element in aerospace vehicle design methodology. NASA has, therefore, initiated the Numerical Aerodynamic Simulation (NAS) Program with the objective to provide a basis for further advances in the modeling of aerodynamic flowfields. The Program is concerned with the development of a leading-edge, large-scale computer facility. This facility is to be made available to Government agencies, industry, and universities as a necessary element in ensuring continuing leadership in computational aerodynamics and related disciplines. Attention is given to the requirements for computational aerodynamics, the principal specific goals of the NAS Program, the high-speed processor subsystem, the workstation subsystem, the support processing subsystem, the graphics subsystem, the mass storage subsystem, the long-haul communication subsystem, the high-speed data-network subsystem, and software.

  7. Potential advantages associated with implementing a risk-based inspection program by a nuclear facility

    NASA Astrophysics Data System (ADS)

    McNeill, Alexander, III; Balkey, Kenneth R.

    1995-05-01

    The current inservice inspection activities at a U.S. nuclear facility are based upon the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code, Section XI. The Code selects examination locations based upon a sampling criteria which includes component geometry, stress, and usage among other criteria. This can result in a significant number of required examinations. As a result of regulatory action each nuclear facility has conducted probabilistic risk assessments (PRA) or individual plant examinations (IPE), producing plant specific risk-based information. Several initiatives have been introduced to apply this new plant risk information. Among these initiatives is risk-based inservice inspection. A code case has been introduced for piping inspections based upon this new risk- based technology. This effort brought forward to the ASME Section XI Code committee, has been initiated and championed by the ASME Research Task Force on Risk-Based Inspection Guidelines -- LWR Nuclear Power Plant Application. Preliminary assessments associated with the code case have revealed that potential advantages exist in a risk-based inservice inspection program with regard to a number of exams, risk, personnel exposure, and cost.

  8. Intensive Hemodialysis and Mortality Risk in Australian and New Zealand Populations.

    PubMed

    Marshall, Mark R; Polkinghorne, Kevan R; Kerr, Peter G; Hawley, Carmel M; Agar, John W M; McDonald, Stephen P

    2016-04-01

    Intensive hemodialysis (HD) is characterized by increased frequency and/or session length compared to conventional HD. Previous analyses from Australia and New Zealand did not suggest benefit with intensive HD, although recent research suggests that relationships have changed. We present updated analyses. Observational cohort study using marginal structural modeling to adjust for changes in renal replacement modality and time-varying medical comorbid conditions. Adults initiating renal replacement therapy since March 31, 1996, followed up through December 31, 2012; this analysis included 40,842 patients over 2,187,689 patient-months. Time-varying renal replacement modality: conventional facility HD (≤3 times per week, ≤6 hours per session), quasi-intensive facility HD (between conventional and intensive), intensive facility HD (≥5 times per week, any hours per session), conventional home HD, quasi-intensive home HD, intensive home HD, peritoneal dialysis, deceased donor kidney transplantation, and living donor kidney transplantation. Patient mortality, with a 3-month lag in primary analyses and 6- and 12-month lags in sensitivity analyses. Conventional facility HD was the reference group. Conventional home HD had a similar mortality risk. For quasi-intensive home HD, mortality risk was lower (HR, 0.56; 95% CI, 0.44-0.73). For intensive home HD, mortality risk was nonsignificantly lower in primary analyses and significantly lower using a 6-month lag (HR, 0.41; 95% CI, 0.20-0.85), but not using a 12-month lag. For quasi-intensive facility HD, mortality risk was nonsignificantly lower in primary analyses, although significantly lower using 6- (HR, 0.41; 95% CI, 0.20-0.85) and 12-month lags (HR, 0.59; 95% CI, 0.44-0.80). Mortality risk was similar between intensive and conventional facility HD. For peritoneal dialysis, mortality risk was greater than for conventional facility HD (HR, 1.07; 95% CI, 1.03-1.12). Kidney transplantation had the lowest mortality risk. Potential residual confounding from limited collection of comorbid condition, socioeconomic, and medication data. There is an emerging HD dose-effect in Australia and New Zealand, with lower mortality risks associated with some of the more intensive HD regimens in these countries. Copyright © 2016 National Kidney Foundation, Inc. Published by Elsevier Inc. All rights reserved.

  9. Elemental Concentrations in Urban Green Stormwater Infrastructure Soils

    Treesearch

    Michelle C. Kondo; Raghav Sharma; Alain F. Plante; Yunwen Yang; Igor Burstyn

    2016-01-01

    Green stormwater infrastructure (GSI) is designed to capture stormwater for infiltration, detention, evapotranspiration, or reuse. Soils play a key role in stormwater interception at these facilities. It is important to assess whether contamination is occurring in GSI soils because urban stormwater drainage areas often accumulate elements of concern. Soil contamination...

  10. Evaluating the Existing School Plant. Educational Facilities Digest 2.

    ERIC Educational Resources Information Center

    Piele, Philip; Wright, Darrell

    In general, the guides for evaluating existing school buildings list the various elements of the building and its properties. The elements commonly listed include site, which embraces the adequacy of size, location, and natural environment; internal environment, which is commonly divided into space, visual qualities, thermal qualities, and sonic…

  11. ECONOMIC AND ENVIRONMENTAL ANALYSIS OF TECHNOLOGIES TO TREAT MERCURY AND DISPOSE IN A WASTE CONTAINMENT FACILITY

    EPA Science Inventory

    This report is intended to describe an economic and environmental analysis of a number of technologies for the treatment and disposal of elemental mercury. The analysis considers three treatment technologies that convert elemental mercury into a stable form of mercury. The techno...

  12. PERSONAL EXPOSURE TO PM2.5 MASS AND TRACE ELEMENTS IN BALTIMORE, MD, USA

    EPA Science Inventory

    In a recent study, EPA found significant relationships between PM2.5 mass measurements at a community site and personal exposure samples in a Towson, MD retirement facility. This manuscript builds upon these results by evaluating the exposure relationships with the elemental c...

  13. 77 FR 9681 - Federal Property Suitable as Facilities To Assist the Homeless

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-17

    ... Property-Duk Property Olympic Nat'l Park Clallam WA 98326 Landholding Agency: Interior Property Number.../environmental elements Lake Quinault Lapham Olympic Nat'l Park Quinault WA 98575 Landholding Agency: Interior.../environmental elements House 574-Ozettee Ranger Resid Olympic Nat'l Park Clallam WA 98326 Landholding Agency...

  14. Measurement of Irradiated Pyroprocessing Samples via Laser Induced Breakdown Spectroscopy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Phongikaroon, Supathorn

    The primary objective of this research is to develop an applied technology and provide an assessment to remotely measure and analyze the real time or near real time concentrations of used nuclear fuel (UNF) dissolute in electrorefiners. Here, Laser-Induced Breakdown Spectroscopy (LIBS), in UNF pyroprocessing facilities will be investigated. LIBS is an elemental analysis method, which is based on the emission from plasma generated by focusing a laser beam into the medium. This technology has been reported to be applicable in the media of solids, liquids (includes molten metals), and gases for detecting elements of special nuclear materials. The advantagesmore » of applying the technology for pyroprocessing facilities are: (i) Rapid real-time elemental analysis|one measurement/laser pulse, or average spectra from multiple laser pulses for greater accuracy in < 2 minutes; (ii) Direct detection of elements and impurities in the system with low detection limits|element specific, ranging from 2-1000 ppm for most elements; and (iii) Near non-destructive elemental analysis method (about 1 g material). One important challenge to overcome is achieving high-resolution spectral analysis to quantitatively analyze all important fission products and actinides. Another important challenge is related to accessibility of molten salt, which is heated in a heavily insulated, remotely operated furnace in a high radiation environment with an argon atmosphere.« less

  15. The Asian clam Corbicula fluminea as a biomonitor of trace element contamination: Accounting for different sources of variation using an hierarchical linear model

    USGS Publications Warehouse

    Shoults-Wilson, W. A.; Peterson, J.T.; Unrine, J.M.; Rickard, J.; Black, M.C.

    2009-01-01

    In the present study, specimens of the invasive clam, Corbicula fluminea, were collected above and below possible sources of potentially toxic trace elements (As, Cd, Cr, Cu, Hg, Pb, and Zn) in the Altamaha River system (Georgia, USA). Bioaccumulation of these elements was quantified, along with environmental (water and sediment) concentrations. Hierarchical linear models were used to account for variability in tissue concentrations related to environmental (site water chemistry and sediment characteristics) and individual (growth metrics) variables while identifying the strongest relations between these variables and trace element accumulation. The present study found significantly elevated concentrations of Cd, Cu, and Hg downstream of the outfall of kaolin-processing facilities, Zn downstream of a tire cording facility, and Cr downstream of both a nuclear power plant and a paper pulp mill. Models of the present study indicated that variation in trace element accumulation was linked to distance upstream from the estuary, dissolved oxygen, percentage of silt and clay in the sediment, elemental concentrations in sediment, shell length, and bivalve condition index. By explicitly modeling environmental variability, the Hierarchical linear modeling procedure allowed the identification of sites showing increased accumulation of trace elements that may have been caused by human activity. Hierarchical linear modeling is a useful tool for accounting for environmental and individual sources of variation in bioaccumulation studies. ?? 2009 SETAC.

  16. Societal acceptance of controversial facilities: The role of two public participation strategies---negotiation and risk communication

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wolfe, A.K.

    Public participation in decision making about the siting of controversial facilities is viewed in contradictory ways by different groups of people. Some see public participation as an impediment, while others think it is an important mechanism in gaining societal acceptance for eventual siting. This paper discusses two strategies for obtaining societal acceptance--- negotiation and risk communication---in light of the extent to which they (1) involve members of the public; (2) focus on risk-related issues; and (3) contribute to decisions to site controversial facilities. The paper presents an integrated conceptual model for public participation in siting decisions that incorporates risk asmore » well as social, political, and historical contexts. 20 refs., 1 fig.« less

  17. A macro environmental risk assessment methodology for establishing priorities among risks to human health and the environment in the Philippines

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gernhofer, S.; Oliver, T.J.; Vasquez, R.

    1994-12-31

    A macro environmental risk assessment (ERA) methodology was developed for the Philippine Department of Environment and Natural Resources (DENR) as part of the US Agency for International Development Industrial Environmental Management Project. The DENR allocates its limited resources to mitigate those environmental problems that pose the greatest threat to human health and the environment. The National Regional Industry Prioritization Strategy (NRIPS) methodology was developed as a risk assessment tool to establish a national ranking of industrial facilities. The ranking establishes regional and national priorities, based on risk factors, that DENR can use to determine the most effective allocation of itsmore » limited resources. NRIPS is a systematic framework that examines the potential risk to human health and the environment from hazardous substances released from a facility, and, in doing so, generates a relative numerical score that represents that risk. More than 3,300 facilities throughout the Philippines were evaluated successfully with the NRIPS.« less

  18. Concept synthesis of an equipment manipulation and transportation system EMATS

    NASA Technical Reports Server (NTRS)

    Depeuter, W.; Waffenschmidt, E.

    1989-01-01

    The European Columbus Scenario is established. One of the Columbus Elements, the Man Tended Free Flyer will be designed for fully autonomous operation in order to provide the environment for micro gravity facilities. The Concept of an autonomous automation system which perform servicing of facilities and deals with related logistic tasks is discussed.

  19. 32 CFR 643.122 - Reserve facilities-Air Force and Navy use.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 32 National Defense 4 2010-07-01 2010-07-01 true Reserve facilities-Air Force and Navy use. 643... Force and Navy use. MACOM may approve local agreements with other Army, DOD, and Reserve elements... Force or Navy Reserve, or which involve a transfer of funds between services for other than minor...

  20. 76 FR 14812 - Final Regulation Extending the Reporting Deadline for Year 2010 Data Elements Required Under the...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-18

    .... Suppliers of Natural Gas and 221210 Natural gas Natural Gas Liquids. distribution facilities. 211112 Natural gas liquid extraction facilities. Suppliers of Industrial 325120 Industrial gas Greenhouse Gases..., 75 FR Natural Gas Liquids. 66434, 75 FR 79092. Suppliers of Industrial OO 74 FR 56260, 75 FR...

  1. Federal Guidelines - Operation and Maintenance of Wastewater Treatment Facilities.

    ERIC Educational Resources Information Center

    Environmental Protection Agency, Washington, DC. Office of Water Programs.

    This document contains the federal guidelines for meeting the specific requirements of the Federal Water Pollution Control Act Amendments of 1972. These guidelines are also intended to assist in meeting the regulations for grant assisted facility construction and to provide information on the key elements to be included in the operation plans for…

  2. The Super Separator Spectrometer S3 and the associated detection systems: SIRIUS & LEB-REGLIS3

    NASA Astrophysics Data System (ADS)

    Déchery, F.; Savajols, H.; Authier, M.; Drouart, A.; Nolen, J.; Ackermann, D.; Amthor, A. M.; Bastin, B.; Berryhill, A.; Boutin, D.; Caceres, L.; Coffey, M.; Delferrière, O.; Dorvaux, O.; Gall, B.; Hauschild, K.; Hue, A.; Jacquot, B.; Karkour, N.; Laune, B.; Le Blanc, F.; Lecesne, N.; Lopez-Martens, A.; Lutton, F.; Manikonda, S.; Meinke, R.; Olivier, G.; Payet, J.; Piot, J.; Pochon, O.; Prince, V.; Souli, M.; Stelzer, G.; Stodel, C.; Stodel, M.-H.; Sulignano, B.; Traykov, E.; Uriot, D.; S3, Sirius; Leb-Reglis3 Collaboration

    2016-06-01

    The Super Separator Spectrometer (S3) facility is developed in the framework of the SPIRAL2 project [1]. S3 has been designed to extend the capability of the facility to perform experiments with extremely low cross sections, taking advantage of the very high intensity stable beams of the superconducting linear accelerator of SPIRAL2. It will mainly use fusion-evaporation reactions to reach extreme regions of the nuclear chart: new opportunities will be opened for super-heavy element studies and spectroscopy at and beyond the driplines. In addition to our previous article (Déchery et al. [2]) introducing the optical layout of the spectrometer and the expected performances, this article will present the current status of the main elements of the facility: the target station, the superconducting multipole, and the magnetic and electric dipoles, with a special emphasis on the status of the detection system SIRIUS and on the low-energy branch which includes the REGLIS3 system. S3 will also be a source of low energy radioactive isotopes for delivery to the DESIR facility.

  3. 77 FR 48970 - Sunshine Act Notice

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-15

    ... DEFENSE NUCLEAR FACILITIES SAFETY BOARD Sunshine Act Notice AGENCY: Defense Nuclear Facilities... given of the Defense Nuclear Facilities Safety Board's (Board) public meeting and hearing described... (NNSA) efforts to mitigate risks to public and worker safety posed by aging defense nuclear facilities...

  4. Fire Hazard Assessment in Supporting Fire Protection System Design of a Chemical Process Facility

    DTIC Science & Technology

    1996-08-01

    CSDP/Studies/FireHaz –i– 3/28/97 FIRE HAZARD ASSESSMENT IN SUPPORTING FIRE PROTECTION SYSTEM DESIGN OF A CHEMICAL PROCESS FACILITY Ali Pezeshk...Joseph Chang, Dwight Hunt, and Peter Jahn Parsons Infrastructure & Technology Group, Inc. Pasadena, California 91124 ABSTRACT Because fires in a chemical ...Assessment in Supporting Fire Protection System Design of a Chemical Process Facility 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6

  5. Assessment of Volatile Organic Compounds (VOCs) in indooor parking facilities at Houston, Texas

    NASA Astrophysics Data System (ADS)

    Kristanto, Gabriel Andari

    This dissertation identified the types, magnitudes, sources, and assessed risk exposure of VOCs in different types of indoor parking facilities. VOCs are ones of major pollutants emitted from automobiles. The indoor parking facilities included were attached garages, grounds, and underground parking. Modification of method TO15 by EPA had been applied for identifying types and magnitudes of VOCs. Results of these identifications are presented. Eight most abundant VOCs could be identified in every sampling location with toluene as the most abundant compound followed by m,p-xylene, ethylbenzene and benzene. Compare to ground and underground parking, attached garages have the highest concentration of TVOCs. For sources identification, BTEX, m,p-xylene and benzene, and toluene and benzene ratios are calculated. BTEX ratios for ground and underground parking are similar compare to attached garage due to the similar pattern of driving speed and the content of gasoline fuel. On the other hand the ratios of m,p-xylene and benzene and toluene and benzene in attached garage are higher compare to the same ratios for ground and underground parking due to other significant contributor of VOCs such as solvent, household cleanings stored. Cancer and noncancer risk assessment were also calculated. Results showed that cancer and noncancer risk due human exposures to VOC in indoor parking facilities were relatively low. However the risk of the human exposure to VOCs from indoor parking facilities has to be considered as a part of total risks of VOC exposures on human during their daily activities. When people in Houston have already exposed to high VOC concentrations from outdoor environment activities such as traffic and refineries and petrochemical facilities, additional activities causing VOC exposures will add the risk significantly.

  6. Launch Pad Flame Trench Refractory Materials

    NASA Technical Reports Server (NTRS)

    Calle, Luz M.; Hintze, Paul E.; Parlier, Christopher R.; Bucherl, Cori; Sampson, Jeffrey W.; Curran, Jerome P.; Kolody, Mark; Perusich, Steve; Whitten, Mary

    2010-01-01

    The launch complexes at NASA's John F. Kennedy Space Center (KSC) are critical support facilities for the successful launch of space-based vehicles. These facilities include a flame trench that bisects the pad at ground level. This trench includes a flame deflector system that consists of an inverted, V-shaped steel structure covered with a high temperature concrete material five inches thick that extends across the center of the flame trench. One side of the "V11 receives and deflects the flames from the orbiter main engines; the opposite side deflects the flames from the solid rocket boosters. There are also two movable deflectors at the top of the trench to provide additional protection to shuttle hardware from the solid rocket booster flames. These facilities are over 40 years old and are experiencing constant deterioration from launch heat/blast effects and environmental exposure. The refractory material currently used in launch pad flame deflectors has become susceptible to failure, resulting in large sections of the material breaking away from the steel base structure and creating high-speed projectiles during launch. These projectiles jeopardize the safety of the launch complex, crew, and vehicle. Post launch inspections have revealed that the number and frequency of repairs, as well as the area and size of the damage, is increasing with the number of launches. The Space Shuttle Program has accepted the extensive ground processing costs for post launch repair of damaged areas and investigations of future launch related failures for the remainder of the program. There currently are no long term solutions available for Constellation Program ground operations to address the poor performance and subsequent failures of the refractory materials. Over the last three years, significant liberation of refractory material in the flame trench and fire bricks along the adjacent trench walls following Space Shuttle launches have resulted in extensive investigations of failure mechanisms, load response, ejected material impact evaluation, and repair design analysis (environmental and structural assessment, induced environment from solid rocket booster plume, loads summary, and repair integrity), assessment of risk posture for flame trench debris, and justification of flight readiness rationale. Although the configuration of the launch pad, water and exhaust direction, and location of the Mobile Launcher Platform between the flame trench and the flight hardware should protect the Space Vehicle from debris exposure, loss of material could cause damage to a major element of the ground facility (resulting in temporary usage loss); and damage to other facility elements is possible. These are all significant risks that will impact ground operations for Constellation and development of new refractory material systems is necessary to reduce the likelihood of the foreign object debris hazard during launch. KSC is developing an alternate refractory material for the launch pad flame trench protection system, including flame deflector and flame trench walls, that will withstand launch conditions without the need for repair after every launch, as is currently the case. This paper will present a summary of the results from industry surveys, trade studies, life cycle cost analysis, and preliminary testing that have been performed to support and validate the development, testing, and qualification of new refractory materials.

  7. Burn-center quality improvement: are burn outcomes dependent on admitting facilities and is there a volume-outcome "sweet-spot"?

    PubMed

    Hranjec, Tjasa; Turrentine, Florence E; Stukenborg, George; Young, Jeffrey S; Sawyer, Robert G; Calland, James F

    2012-05-01

    Risk factors of mortality in burn patients such as inhalation injury, patient age, and percent of total body surface area (%TBSA) burned have been identified in previous publications. However, little is known about the variability of mortality outcomes between burn centers and whether the admitting facilities or facility volumes can be recognized as predictors of mortality. De-identified data from 87,665 acute burn observations obtained from the National Burn Repository between 2003 and 2007 were used to estimate a multivariable logistic regression model that could predict patient mortality with reference to the admitting burn facility/facility volume, adjusted for differences in age, inhalation injury, %TBSA burned, and an additional factor, percent full thickness burn (%FTB). As previously reported, all three covariates (%TBSA burned, inhalation injury, and age) were found to be highly statistically significant risk factors of mortality in burn patients (P value < 0.0001). The additional variable, %FTB, was also found to be a statistically significant determinant, although it did not greatly improve the multivariable model. The treatment/admitting facility was found to be an independent mortality predictor, with certain hospitals having increased odds of death and others showing a protective effect (decreased odds ratio). Hospitals with high burn volumes had the highest risk of mortality. Mortality outcomes of patients with similar risk factors (%TBSA burned, inhalation injury, age, and %FTB) are significantly affected by the treating facility and their admission volumes.

  8. Petroleum and hazardous material releases from industrial facilities associated with Hurricane Katrina.

    PubMed

    Santella, Nicholas; Steinberg, Laura J; Sengul, Hatice

    2010-04-01

    Hurricane Katrina struck an area dense with industry, causing numerous releases of petroleum and hazardous materials. This study integrates information from a number of sources to describe the frequency, causes, and effects of these releases in order to inform analysis of risk from future hurricanes. Over 200 onshore releases of hazardous chemicals, petroleum, or natural gas were reported. Storm surge was responsible for the majority of petroleum releases and failure of storage tanks was the most common mechanism of release. Of the smaller number of hazardous chemical releases reported, many were associated with flaring from plant startup, shutdown, or process upset. In areas impacted by storm surge, 10% of the facilities within the Risk Management Plan (RMP) and Toxic Release Inventory (TRI) databases and 28% of SIC 1311 facilities experienced accidental releases. In areas subject only to hurricane strength winds, a lower fraction (1% of RMP and TRI and 10% of SIC 1311 facilities) experienced a release while 1% of all facility types reported a release in areas that experienced tropical storm strength winds. Of industrial facilities surveyed, more experienced indirect disruptions such as displacement of workers, loss of electricity and communication systems, and difficulty acquiring supplies and contractors for operations or reconstruction (55%), than experienced releases. To reduce the risk of hazardous material releases and speed the return to normal operations under these difficult conditions, greater attention should be devoted to risk-based facility design and improved prevention and response planning.

  9. Risk Management Technique for design and operation of facilities and equipment

    NASA Technical Reports Server (NTRS)

    Fedor, O. H.; Parsons, W. N.; Coutinho, J. De S.

    1975-01-01

    The Risk Management System collects information from engineering, operating, and management personnel to identify potentially hazardous conditions. This information is used in risk analysis, problem resolution, and contingency planning. The resulting hazard accountability system enables management to monitor all identified hazards. Data from this system are examined in project reviews so that management can decide to eliminate or accept these risks. This technique is particularly effective in improving the management of risks in large, complex, high-energy facilities. These improvements are needed for increased cooperation among industry, regulatory agencies, and the public.

  10. Effect of Community Engagement Interventions on Patient Safety and Risk Reduction Efforts in Primary Health Facilities: Evidence from Ghana

    PubMed Central

    Alhassan, Robert Kaba; Nketiah-Amponsah, Edward; Spieker, Nicole; Arhinful, Daniel Kojo; Ogink, Alice; van Ostenberg, Paul; Rinke de Wit, Tobias F.

    2015-01-01

    Background Patient safety and quality care remain major challenges to Ghana’s healthcare system. Like many health systems in Africa, this is largely because demand for healthcare is outstripping available human and material resource capacity of healthcare facilities and new investment is insufficient. In the light of these demand and supply constraints, systematic community engagement (SCE) in healthcare quality assessment can be a feasible and cost effective option to augment existing quality improvement interventions. SCE entails structured use of existing community groups to assess healthcare quality in health facilities. Identified quality gaps are discussed with healthcare providers, improvements identified and rewards provided if the quality gaps are closed. Purpose This paper evaluates whether or not SCE, through the assessment of health service quality, improves patient safety and risk reduction efforts by staff in healthcare facilities. Methods A randomized control trail was conducted in 64 primary healthcare facilities in the Greater Accra and Western regions of Ghana. Patient risk assessments were conducted in 32 randomly assigned intervention and control facilities. Multivariate multiple regression test was used to determine effect of the SCE interventions on staff efforts towards reducing patient risk. Spearman correlation test was used to ascertain associations between types of community groups engaged and risk assessment scores of healthcare facilities. Findings Clinic staff efforts towards increasing patient safety and reducing risk improved significantly in intervention facilities especially in the areas of leadership/accountability (Coef. = 10.4, p<0.05) and staff competencies (Coef. = 7.1, p<0.05). Improvement in service utilization and health resources could not be attributed to the interventions because these were outside the control of the study and might have been influenced by institutional or national level developments between the baseline and follow-up period. Community groups that were gender balanced, religious/faith-based, and had structured leadership appeared to be better options for effective SCE in healthcare quality assessment. Conclusion Community engagement in healthcare quality assessment is a feasible client-centered quality improvement option that should be discussed for possible scale-up in Ghana and other resource poor countries in Africa. PMID:26619143

  11. Effect of Community Engagement Interventions on Patient Safety and Risk Reduction Efforts in Primary Health Facilities: Evidence from Ghana.

    PubMed

    Alhassan, Robert Kaba; Nketiah-Amponsah, Edward; Spieker, Nicole; Arhinful, Daniel Kojo; Ogink, Alice; van Ostenberg, Paul; Rinke de Wit, Tobias F

    2015-01-01

    Patient safety and quality care remain major challenges to Ghana's healthcare system. Like many health systems in Africa, this is largely because demand for healthcare is outstripping available human and material resource capacity of healthcare facilities and new investment is insufficient. In the light of these demand and supply constraints, systematic community engagement (SCE) in healthcare quality assessment can be a feasible and cost effective option to augment existing quality improvement interventions. SCE entails structured use of existing community groups to assess healthcare quality in health facilities. Identified quality gaps are discussed with healthcare providers, improvements identified and rewards provided if the quality gaps are closed. This paper evaluates whether or not SCE, through the assessment of health service quality, improves patient safety and risk reduction efforts by staff in healthcare facilities. A randomized control trail was conducted in 64 primary healthcare facilities in the Greater Accra and Western regions of Ghana. Patient risk assessments were conducted in 32 randomly assigned intervention and control facilities. Multivariate multiple regression test was used to determine effect of the SCE interventions on staff efforts towards reducing patient risk. Spearman correlation test was used to ascertain associations between types of community groups engaged and risk assessment scores of healthcare facilities. Clinic staff efforts towards increasing patient safety and reducing risk improved significantly in intervention facilities especially in the areas of leadership/accountability (Coef. = 10.4, p<0.05) and staff competencies (Coef. = 7.1, p<0.05). Improvement in service utilization and health resources could not be attributed to the interventions because these were outside the control of the study and might have been influenced by institutional or national level developments between the baseline and follow-up period. Community groups that were gender balanced, religious/faith-based, and had structured leadership appeared to be better options for effective SCE in healthcare quality assessment. Community engagement in healthcare quality assessment is a feasible client-centered quality improvement option that should be discussed for possible scale-up in Ghana and other resource poor countries in Africa.

  12. NASA Reactor Facility Hazards Summary. Volume 1

    NASA Technical Reports Server (NTRS)

    1959-01-01

    The Lewis Research Center of the National Aeronautics and Space Administration proposes to build a nuclear research reactor which will be located in the Plum Brook Ordnance Works near Sandusky, Ohio. The purpose of this report is to inform the Advisory Committee on Reactor Safeguards of the U. S. Atomic Energy Commission in regard to the design Lq of the reactor facility, the characteristics of the site, and the hazards of operation at this location. The purpose of this research reactor is to make pumped loop studies of aircraft reactor fuel elements and other reactor components, radiation effects studies on aircraft reactor materials and equipment, shielding studies, and nuclear and solid state physics experiments. The reactor is light water cooled and moderated of the MTR-type with a primary beryllium reflector and a secondary water reflector. The core initially will be a 3 by 9 array of MTR-type fuel elements and is designed for operation up to a power of 60 megawatts. The reactor facility is described in general terms. This is followed by a discussion of the nuclear characteristics and performance of the reactor. Then details of the reactor control system are discussed. A summary of the site characteristics is then presented followed by a discussion of the larger type of experiments which may eventually be operated in this facility. The considerations for normal operation are concluded with a proposed method of handling fuel elements and radioactive wastes. The potential hazards involved with failures or malfunctions of this facility are considered in some detail. These are examined first from the standpoint of preventing them or minimizing their effects and second from the standpoint of what effect they might have on the reactor facility staff and the surrounding population. The most essential feature of the design for location at the proposed site is containment of the maximum credible accident.

  13. Space Radiation Program Element

    NASA Technical Reports Server (NTRS)

    Krenek, Sam

    2008-01-01

    This poster presentation shows the various elements of the Space Radiation Program. It reviews the program requirements: develop and validate standards, quantify space radiation human health risks, mitigate risks through countermeasures and technologies, and treat and monitor unmitigated risks.

  14. Ergonomics and simulation-based approach in improving facility layout

    NASA Astrophysics Data System (ADS)

    Abad, Jocelyn D.

    2018-02-01

    The use of the simulation-based technique in facility layout has been a choice in the industry due to its convenience and efficient generation of results. Nevertheless, the solutions generated are not capable of addressing delays due to worker's health and safety which significantly impact overall operational efficiency. It is, therefore, critical to incorporate ergonomics in facility design. In this study, workstation analysis was incorporated into Promodel simulation to improve the facility layout of a garment manufacturing. To test the effectiveness of the method, existing and improved facility designs were measured using comprehensive risk level, efficiency, and productivity. Results indicated that the improved facility layout generated a decrease in comprehensive risk level and rapid upper limb assessment score; an increase of 78% in efficiency and 194% increase in productivity compared to existing design and thus proved that the approach is effective in attaining overall facility design improvement.

  15. Fuel shipment experience, fuel movements from the BMI-1 transport cask

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bauer, Thomas L.; Krause, Michael G

    1986-07-01

    The University of Texas at Austin received two shipments of irradiated fuel elements from Northrup Aircraft Corporation on April 11 and 16, 1985. A total of 59 elements consisting of standard and instrumented TRIGA fuel were unloaded from the BMI-1 shipping cask. At the time of shipment, the Northrup core burnup was approximately 50 megawatt days with fuel element radiation levels, after a cooling time of three months, of approximately 1.75 rem/hr at 3 feet. In order to facilitate future planning of fuel shipment at the UT facility and other facilities, a summary of the recent transfer process including severalmore » factors which contributed to its success are presented. Numerous color slides were made of the process for future reference by UT and others involved in fuel transfer and handling of the BMI-1 cask.« less

  16. Ambient concentrations of total suspended particulate matter and its elemental constituents at the wider area of the mining facilities of TVX Hellas in Chalkidiki, Greece.

    PubMed

    Gaidajis, George

    2003-01-01

    To assess ambient air quality at the wider area of TVX Hellas mining facilities, the Total Suspended Particulate matter (TSP) and its content in characteristic elements, i.e., As, Cd, Cu, Fe, Mn, Pb, Zn are being monitored for more than thirty months as part of the established Environmental Monitoring Program. High Volume air samplers equipped with Tissue Quartz filters were employed for the collection of TSP. Analyses were effected after digestion of the suspended particulate with an HNO3-HCl solution and determination of elemental concentrations with an Atomic Absorption Spectroscopy equipped with graphite furnace. The sampling stations were selected to record representatively the existing ambient air quality in the vicinity of the facilities and at remote sites not affected from industrial activities. Monitoring data indicated that the background TSP concentrations ranged from 5-60 microg/m3. Recorded TSP concentrations at the residential sites close to the facilities ranged between 20-100 microg/m3, indicating only a minimal influence from the mining and milling activities. Similar spatial variation was observed for the TSP constituents and specifically for Pb and Zn. To validate the monitoring procedures, a parallel sampling campaign took place with different High Volume samplers at days where low TSP concentrations were expected. The satisfactory agreement (+/- 11%) at low concentrations (50-100 microg/m3) clearly supported the reproducibility of the techniques employed specifically at the critical range of lower concentrations.

  17. The importance of public sector health facility-level data for monitoring changes in maternal mortality risks among communities: the case of pakistan.

    PubMed

    Jain, Anrudh K; Sathar, Zeba; Salim, Momina; Shah, Zakir Hussain

    2013-09-01

    This paper illustrates the importance of monitoring health facility-level information to monitor changes in maternal mortality risks. The annual facility-level maternal mortality ratios (MMRs), complications to live births ratios and case fatality ratios (CFRs) were computed from data recorded during 2007 and 2009 in 31 upgraded public sector health facilities across Pakistan. The facility-level MMR declined by about 18%; both the number of Caesarean sections and the episodes of complications as a percentage of live births increased; and CFR based on Caesarean sections and episodes of complications declined by 29% and 37%, respectively. The observed increases in the proportion of women with complications among those who come to these facilities point to a reduction in the delay in reaching facilities (first and second delays; Thaddeus & Maine, 1994); the decrease in CFRs points to improvements in treating obstetric complications and a reduction in the delay in receiving treatment once at facilities (the third delay). These findings point to a decline in maternal mortality risks among communities served by these facilities. A system of woman-level data collection instituted at health facilities with comprehensive emergency obstetric care is essential to monitor changes in the effects of any reduction in the three delays and any improvement in quality of care or the effectiveness of treating pregnancy-related complications among women reaching these facilities. Such a system of information gathering at these health facilities would also help policymakers and programme mangers to measure and improve the effectiveness of safe-motherhood initiatives and to monitor progress being made toward achieving the fifth Millennium Development Goal.

  18. Academic status does not affect outcome following complex hepato-pancreato-biliary procedures.

    PubMed

    Altieri, Maria S; Yang, Jie; Groves, Donald; Yin, Donglei; Cagino, Kristen; Talamini, Mark; Pryor, Aurora

    2018-05-01

    There is a growing debate regarding outcomes following complex hepato-pancreato-biliary (HPB) procedures. The purpose of our study is to examine if facility type has any impact on complications, readmission rates, emergency department (ED) visit rates, and length of stay (LOS) for patients undergoing HPB surgery. The SPARCS administrative database was used to identify patients undergoing complex HPB procedures between 2012 and 2014 in New York. Univariate generalized linear mixed models were fit to estimate the marginal association between outcomes such as overall/severe complication rates, 30-day and 1-year readmission rates, 30-day and 1-year ED-visit rates, and potential risk factors. Univariate linear mixed models were used to estimate the marginal association between possible risk factors and LOS. Facility type, as well as any variables found to be significant in our univariate analysis (p = 0.05), was further included in the multivariable regression models. There were 4122 complex HPB procedures performed. Academic facilities were more likely to have a higher hospital volume (p < 0001). Surgery at academic facilities were less likely to have coexisting comorbidities; however, they were more likely to have metastatic cancer and/or liver disease (p = 0.0114, < 0. 0001, and = 0.0299, respectively). Postoperatively, patients at non-academic facilities experienced higher overall complication rates, and higher severe complication rates, when compared to those at academic facilities (p < 0.0001 and = 0.0018, respectively). Further analysis via adjustment for possible confounding factors, however, revealed no significant difference in the risk of severe complications between the two facility types. Such adjustment also demonstrated higher 30-day readmission risk in patients who underwent their surgery at an academic facility. No significant difference was found when comparing the outcomes of academic and non-academic facilities, after adjusting for age, gender, race, region, insurance, and hospital volume. Patients from academic facilities were more likely to be readmitted within the first 30-days after surgery.

  19. Waste to energy--key element for sustainable waste management.

    PubMed

    Brunner, Paul H; Rechberger, Helmut

    2015-03-01

    Human activities inevitably result in wastes. The higher the material turnover, and the more complex and divers the materials produced, the more challenging it is for waste management to reach the goals of "protection of men and environment" and "resource conservation". Waste incineration, introduced originally for volume reduction and hygienic reasons, went through a long and intense development. Together with prevention and recycling measures, waste to energy (WTE) facilities contribute significantly to reaching the goals of waste management. Sophisticated air pollution control (APC) devices ensure that emissions are environmentally safe. Incinerators are crucial and unique for the complete destruction of hazardous organic materials, to reduce risks due to pathogenic microorganisms and viruses, and for concentrating valuable as well as toxic metals in certain fractions. Bottom ash and APC residues have become new sources of secondary metals, hence incineration has become a materials recycling facility, too. WTE plants are supporting decisions about waste and environmental management: They can routinely and cost effectively supply information about chemical waste composition as well as about the ratio of biogenic to fossil carbon in MSW and off-gas. Copyright © 2014 Elsevier Ltd. All rights reserved.

  20. Systematic, appropriate, and cost-effective application of security technologies in U.S. public schools to reduce crime, violence, and drugs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Green, M.W.

    As problems of violence and crime become more prevalent in our schools (or at least the perception of their prevalence), more and more school districts will elect to use security technologies to control these problems. While the desired change in student and community attitudes will require significant systemic change through intense U.S. social programs, security technologies can greatly augment school staff today by providing services similar to having extra adults present. Technologies such as cameras, sensors, drug detection, biometric and personnel identification, lighting, barriers, weapon and explosives detection, anti-graffiti methods, and duress alarms can all be effective, given they aremore » used in appropriate applications, with realistic expectations and an understanding of limitations. Similar to a high-risk government facility, schools must consider a systems (`big picture`) approach to security, which includes the use of personnel and procedures as well as security technologies, such that the synergy created by all these elements together contributes more to the general `order maintenance` of the facility than could be achieved by separate measures not integrated or related.« less

  1. Dose and Dose Risk Caused by Natural Phenomena - Proposed Powder Metallurgy Core Manufacturing Facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Holmes, W.G.

    2001-08-16

    The offsite radiological effects from high velocity straight winds, tornadoes, and earthquakes have been estimated for a proposed facility for manufacturing enriched uranium fuel cores by powder metallurgy. Projected doses range up to 30 mrem/event to the maximum offsite individual for high winds and up to 85 mrem/event for very severe earthquakes. Even under conservative assumptions on meteorological conditions, the maximum offsite dose would be about 20 per cent of the DOE limit for accidents involving enriched uranium storage facilities. The total dose risk is low and is dominated by the risk from earthquakes. This report discusses this test.

  2. Trace elements contamination and human health risk assessment in drinking water from Shenzhen, China.

    PubMed

    Lu, Shao-You; Zhang, Hui-Min; Sojinu, Samuel O; Liu, Gui-Hua; Zhang, Jian-Qing; Ni, Hong-Gang

    2015-01-01

    The levels of seven essential trace elements (Mn, Co, Ni, Cu, Zn, Se, and Mo) and six non-essential trace elements (Cr, As, Cd, Sb, Hg, and Pb) in a total of 89 drinking water samples collected in Shenzhen, China were determined using inductively coupled plasma mass spectrometry (ICP-MS) in the present study. Both the essential and non-essential trace elements were frequently detectable in the different kinds of drinking waters assessed. Remarkable temporal and spatial variations were observed among most of the trace elements in the tap water collected from two tap water treatment plants. Meanwhile, potential human health risk from these non-essential trace elements in the drinking water for local residents was also assessed. The median values of cancer risks associated with exposure to carcinogenic metals via drinking water consumption were estimated to be 6.1 × 10(-7), 2.1 × 10(-8), and 2.5 × 10(-7) for As, Cd, and Cr, respectively; the median values of incremental lifetime for non-cancer risks were estimated to be 6.1 × 10(-6), 4.4 × 10(-5), and 2.2 × 10(-5) for Hg, Pb, and Sb, respectively. The median value of total incremental lifetime health risk induced by the six non-essential trace elements for the population was 3.5 × 10(-5), indicating that the potential health risks from non-carcinogenic trace elements in drinking water also require some attention. Sensitivity analysis indicates that the most important factor for health risk assessment should be the levels of heavy metal in drinking water.

  3. Oil sands development and its impact on atmospheric wet deposition of air pollutants to the Athabasca Oil Sands Region, Alberta, Canada.

    PubMed

    Lynam, Mary M; Dvonch, J Timothy; Barres, James A; Morishita, Masako; Legge, Allan; Percy, Kevin

    2015-11-01

    Characterization of air pollutant deposition resulting from Athabasca oil sands development is necessary to assess risk to humans and the environment. To investigate this we collected event-based wet deposition during a pilot study in 2010-2012 at the AMS 6 site 30 km from the nearest upgrading facility in Fort McMurray, AB, Canada. Sulfate, nitrate and ammonium deposition was (kg/ha) 1.96, 1.60 and 1.03, respectively. Trace element pollutant deposition ranged from 2 × 10(-5) - 0.79 and exhibited the trend Hg < Se < As < Cd < Pb < Cu < Zn < S. Crustal element deposition ranged from 1.4 × 10(-4) - 0.46 and had the trend: La < Ce < Sr < Mn < Al < Fe < Mg. S, Se and Hg demonstrated highest median enrichment factors (130-2020) suggesting emissions from oil sands development, urban activities and forest fires were deposited. High deposition of the elements Sr, Mn, Fe and Mg which are tracers for soil and crustal dust implies land-clearing, mining and hauling emissions greatly impacted surrounding human settlements and ecosystems. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. Surface-Cycling of Rhenium and its Isotopes

    DTIC Science & Technology

    2009-06-01

    Fisher Scientific) in the WHOI plasma facility. Samples were introduced using a PFA MicroFlow nebulizer (Elemental Scientific Incorporated), a quartz...Samples were introduced using a PFA MicroFlow nebulizer (Elemental Scientific Incorporated), a quartz spray chamber, and regular cones. Analyses are done in...189Os. Samples dissolved in 1 mL of 0.5 molL−1 HNO3 are introduced using a PFA MicroFlow nebulizer (Elemental Scientific Incorporated), a quartz spray

  5. Hurricane risk mitigation - High Pressure Gas Facility

    NASA Image and Video Library

    2008-07-29

    A worker pours concrete as part of a nitrogen risk mitigation project at the High Pressure Gas Facility at Stennis Space Center. The concrete slab will provide the foundation needed to place new pumps at the site and is part of ongoing hurricane-related mitigation work at Stennis.

  6. Medical Waste Management Implications for Small Medical Facilities.

    ERIC Educational Resources Information Center

    Byrns, George; Burke, Thomas

    1992-01-01

    Discusses the implications of the Medical Waste Management Act of 1988 for small medical facilities, public health, and the environment. Reviews health and environmental risks associated with medical waste, current regulatory approaches, and classifications. Concludes that the health risk of medical wastes has been overestimated; makes…

  7. Hurricane risk mitigation - High Pressure Gas Facility

    NASA Technical Reports Server (NTRS)

    2008-01-01

    A worker pours concrete as part of a nitrogen risk mitigation project at the High Pressure Gas Facility at Stennis Space Center. The concrete slab will provide the foundation needed to place new pumps at the site and is part of ongoing hurricane-related mitigation work at Stennis.

  8. THE USEPA'S METAL FINISHING FACILITY RISK SCREENING TOOL (MFFRST)

    EPA Science Inventory

    The US Environmetal ProtectionAgenccy's Metal Finishing
    Facility Risk Screening Tool (MFFRST)

    William M. Barrett Jr, Ph.D. , P.E. ; Paul Harten, Ph.D.1, and Matthew Lorber

    The US Environmental Protection Agency completed the development of the first version of...

  9. 78 FR 48029 - Improving Chemical Facility Safety and Security

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-07

    ... responding to risks in chemical facilities (including during pre-inspection, inspection execution, post.... Sec. 2. Establishment of the Chemical Facility Safety and Security Working Group. (a) There is established a Chemical Facility Safety and Security Working Group (Working Group) co-chaired by the Secretary...

  10. Nuclear Cryogenic Propulsion Stage (NCPS) Fuel Element Testing in the Nuclear Thermal Rocket Element Environmental Simulator (NTREES)

    NASA Technical Reports Server (NTRS)

    Emrich, William J., Jr.

    2017-01-01

    To support the on-going nuclear thermal propulsion effort, a state-of-the-art non nuclear experimental test setup has been constructed to evaluate the performance characteristics of candidate fuel element materials and geometries in representative environments. The facility to perform this testing is referred to as the Nuclear Thermal Rocket Element Environment Simulator (NTREES). Last year NTREES was successfully used to satisfy a testing milestone for the Nuclear Cryogenic Propulsion Stage (NCPS) project and met or exceeded all required objectives.

  11. Magnetohydrodynamics (MHD) Engineering Test Facility (ETF) 200 MWe power plant Conceptual Design Engineering Report (CDER)

    NASA Technical Reports Server (NTRS)

    1981-01-01

    The reference conceptual design of the magnetohydrodynamic (MHD) Engineering Test Facility (ETF), a prototype 200 MWe coal-fired electric generating plant designed to demonstrate the commercial feasibility of open cycle MHD, is summarized. Main elements of the design, systems, and plant facilities are illustrated. System design descriptions are included for closed cycle cooling water, industrial gas systems, fuel oil, boiler flue gas, coal management, seed management, slag management, plant industrial waste, fire service water, oxidant supply, MHD power ventilating

  12. DESIGN CRITERIA FOR FUEL DISSOLUTION SYSTEMS AND ASSOCIATED SERVICE FACILITIES. PLANT MODIFICATIONS FOR REPROCESSING NON-PRODUCTION REACTOR FUELS. PROJECT CGC-830

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bierman, S.R.; Graf, W.A.; Kass, M.

    1960-07-29

    Design panameters are presented for phases of the facility to reprocess low-enrichment fuels from nonproduction reactors. Included are plant flowsheets and equipment layouts for fuel element dissolution, centrifugation, solution adjustment, and waste handling. Also included are the basic design criteria for the supporting facilities which service these phases and all other facilites located in the vicinity of the selected building (Bldg. 221-U). (J.R.D.)

  13. Magnetohydrodynamics (MHD) Engineering Test Facility (ETF) 200 MWe power plant Conceptual Design Engineering Report (CDER)

    NASA Astrophysics Data System (ADS)

    1981-09-01

    The reference conceptual design of the magnetohydrodynamic (MHD) Engineering Test Facility (ETF), a prototype 200 MWe coal-fired electric generating plant designed to demonstrate the commercial feasibility of open cycle MHD, is summarized. Main elements of the design, systems, and plant facilities are illustrated. System design descriptions are included for closed cycle cooling water, industrial gas systems, fuel oil, boiler flue gas, coal management, seed management, slag management, plant industrial waste, fire service water, oxidant supply, MHD power ventilating

  14. An oxidation and erosion test facility for cooled panels

    NASA Technical Reports Server (NTRS)

    Swartwout, W. H.; Erdos, J. I.; Engers, R. J.; Prescott, C.

    1992-01-01

    The Panel Oxidation and Erosion Testbed (POET) facility under construction at GASL to provide the required test environment is described. The POET facility comprises three major element including a vitiated air heater, a supersonic nozzle, and a test section. A hydrogen-fueld vitiated air heater will provide the oxidizing and erosive environment. The flow through the test section characterized by low supersonic speed and Mach number of 1.4 will maximize the local heat transfer rate and the local surface shear stress.

  15. Reference earth orbital research and applications investigations (blue book). Volume 8: Life sciences

    NASA Technical Reports Server (NTRS)

    1971-01-01

    The functional program element for the life sciences facilities to operate aboard manned space stations is presented. The life sciences investigations will consist of the following subjects: (1) medical research, (2) vertebrate research, (3) plant research, (4) cells and tissue research, (5) invertebrate research, (6) life support and protection, and (7) man-system integration. The equipment required to provide the desired functional capability for the research facilities is defined. The goals and objectives of each research facility are described.

  16. Extraterrestrial processing and manufacturing of large space systems. Volume 3: Executive summary

    NASA Technical Reports Server (NTRS)

    Miller, R. H.; Smith, D. B. S.

    1979-01-01

    Facilities and equipment are defined for refining processes to commercial grade of lunar material that is delivered to a 'space manufacturing facility' in beneficiated, primary processed quality. The manufacturing facilities and the equipment for producing elements of large space systems from these materials and providing programmatic assessments of the concepts are also defined. In-space production processes of solar cells (by vapor deposition) and arrays, structures and joints, conduits, waveguides, RF equipment radiators, wire cables, converters, and others are described.

  17. Reference earth orbital research and applications investigations (blue book). Volume 4: Earth observations

    NASA Technical Reports Server (NTRS)

    1971-01-01

    The earth observations capability of the space station and space shuttle program definition is discussed. The stress in the functional program element has been to update the sensor specifications and to shift some of the emphasis from sensors to experiments to be done aboard the facility. The earth observations facility will include provisions for data acquisition, sensor control and display, data analysis, and maintenance and repair. The facility is research and development in nature with a potential for operational applications.

  18. Sandia QIS Capabilities.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Muller, Richard P.

    2017-07-01

    Sandia National Laboratories has developed a broad set of capabilities in quantum information science (QIS), including elements of quantum computing, quantum communications, and quantum sensing. The Sandia QIS program is built atop unique DOE investments at the laboratories, including the MESA microelectronics fabrication facility, the Center for Integrated Nanotechnologies (CINT) facilities (joint with LANL), the Ion Beam Laboratory, and ASC High Performance Computing (HPC) facilities. Sandia has invested $75 M of LDRD funding over 12 years to develop unique, differentiating capabilities that leverage these DOE infrastructure investments.

  19. Empirical estimation of the conditional probability of natech events within the United States.

    PubMed

    Santella, Nicholas; Steinberg, Laura J; Aguirra, Gloria Andrea

    2011-06-01

    Natural disasters are the cause of a sizeable number of hazmat releases, referred to as "natechs." An enhanced understanding of natech probability, allowing for predictions of natech occurrence, is an important step in determining how industry and government should mitigate natech risk. This study quantifies the conditional probabilities of natechs at TRI/RMP and SICS 1311 facilities given the occurrence of hurricanes, earthquakes, tornadoes, and floods. During hurricanes, a higher probability of releases was observed due to storm surge (7.3 releases per 100 TRI/RMP facilities exposed vs. 6.2 for SIC 1311) compared to category 1-2 hurricane winds (5.6 TRI, 2.6 SIC 1311). Logistic regression confirms the statistical significance of the greater propensity for releases at RMP/TRI facilities, and during some hurricanes, when controlling for hazard zone. The probability of natechs at TRI/RMP facilities during earthquakes increased from 0.1 releases per 100 facilities at MMI V to 21.4 at MMI IX. The probability of a natech at TRI/RMP facilities within 25 miles of a tornado was small (∼0.025 per 100 facilities), reflecting the limited area directly affected by tornadoes. Areas inundated during flood events had a probability of 1.1 releases per 100 facilities but demonstrated widely varying natech occurrence during individual events, indicating that factors not quantified in this study such as flood depth and speed are important for predicting flood natechs. These results can inform natech risk analysis, aid government agencies responsible for planning response and remediation after natural disasters, and should be useful in raising awareness of natech risk within industry. © 2011 Society for Risk Analysis.

  20. 77 FR 12076 - Final Programmatic Environmental Impact Statement and Integrated Water Resource Management Plan...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-28

    ..., Systems Modification, and Water Supply) which are comprised of seven elements (listed below). The Habitat... existing facilities and operations in order to improve conditions for fish and to improve water supply. The... elements. The third component, Water Supply, is intended to improve water supply for agricultural and...

  1. 10 CFR Appendix I to Part 110 - Illustrative List of Reprocessing Plant Components Under NRC Export Licensing Authority

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... transuranic elements. Different technical processes can accomplish this separation. However, over the years Purex has become the most commonly used and accepted process. Purex involves the dissolution of... facilities have process functions similar to each other, including: irradiated fuel element chopping, fuel...

  2. Floating Double Deck Pier Fenders

    DTIC Science & Technology

    2011-07-01

    Center FDDP Floating Double Deck Pier FEM Finite Element Model MHP Modular Hybrid Pier NAVFAC Naval Facilities RDT&E Research, Development, Testing...4. FEM Performance of MV1000x900B Elements ........................................................ 14 Figure 4-5. Biaxial UE1200x1200E3.1 Fender...Deflection .......................................................... 15 Figure 4-6. FEM Performance of Biaxial UE Fender

  3. Exobiology and life science

    NASA Technical Reports Server (NTRS)

    Mckay, C. P.

    1987-01-01

    The following types of experiments for a proposed Space Station Microgravity Particle Research Facility are described: (1) biogenic elements in the interstellar medium; (2) organic material in the solar nebula; (3) volatiles in comets and icy planetesimals; (4) pre-biotic atmospheric chemistry; (5) analysis of cosmic dust particles; and (6) microbial exposure. The required capabilities and desired hardware for the facility are detailed.

  4. Nuclear Security Objectives of an NMAC System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    West, Rebecca Lynn

    After completing this module, you should be able to: Describe the role of Nuclear Material Accounting and Control (NMAC) in comprehensive nuclear security at a facility; Describe purpose of NMAC; Identify differences between the use of NMAC for IAEA safeguards and for facility nuclear security; List NMAC elements and measures; and Describe process for resolution of irregularities

  5. The differential associations of preexisting conditions with trauma-related outcomes in the presence of competing risks.

    PubMed

    Calvo, Richard Yee; Lindsay, Suzanne P; Edland, Steven D; Macera, Caroline A; Wingard, Deborah L; Ohno-Machado, Lucila; Sise, Michael J

    2016-03-01

    Pre-existing chronic conditions (PECs) pose a unique problem for the care of aging trauma populations. However, the relationships between specific conditions and outcomes after injury are relatively unknown. Evaluation of trauma patients is further complicated by their discharge to care facilities, where mortality risk remains high. Traditional approaches for evaluating in-hospital mortality do not account for the discharge of at-risk patients, which constitutes a competing risk event to death. The objective of this study was to evaluate associations between 40 PECs and two clinical outcomes in the context of competing risks among older trauma patients. This retrospective study evaluated blunt-injured patients aged 55 years and older admitted to a level I trauma centre in 2006-2012. Outcomes were hospital length of stay (HLOS) and in-hospital mortality. Survivors were classified as discharges home or discharges to care facilities. Competing risks regression was used to evaluate each PEC with in-hospital mortality, accounting for discharges to care facilities as competing events. Competing risk estimates were compared to Cox model estimates, for which all survivors to discharge were non-events. Analyses were stratified using injury-based mortality risk at a 50% cutpoint (high versus low). Among 4653 patients, 176 died in-hospital, 3059 were discharged home, and 1418 were discharged to a care facility. Most patients (98%) were classified with a low mortality risk. Only haemophilia and coagulopathy were consistently associated with longer HLOS. In the low-risk subgroup, in-hospital mortality was most strongly associated with liver diseases, haemophilia, and coagulopathy. In the high-risk group, Parkinson's disease, depression, and cancers showed the strongest associations. Accounting for the competing event altered estimates for 12 of 19 significant conditions. Excess mortality among patients expected to survive their injuries may be attributable to complications resulting from PECs. Discharges to care facilities constitute a bias in the evaluation of in-hospital mortality and should be considered for the accurate calculation of risk. In conjunction with injury measures, consideration of PECs provides physicians with a foundation to plan clinical decisions in older trauma patients. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. Cast Coil Transformer Fire Susceptibility and Reliability Study

    DTIC Science & Technology

    1991-04-01

    transformers reduce risk to the user compared to liquid-filled units, eliminate environmental impacts, are more efficient than most transformer designs, and...filled units, eliminate environmental impacts, arc more efficient than most transformer designs, and add minimal risk to the facility in a fire situation...add minimal risk to the facility in a fire situation. Cast coil transformers have a long record of operation and have proven to be reliable and

  7. Indoor air quality investigation and health risk assessment at correctional institutions.

    PubMed

    Ofungwu, Joseph

    2005-04-01

    A comprehensive indoor air-quality (IAQ) investigation was conducted at a state correctional facility in New Jersey, USA with a lengthy history of IAQ problems. The IAQ investigation comprised preliminary indoor air screening using direct readout instrumentation, indoor air/surface wipe sampling and laboratory analysis, as well as a heating, ventilation, and air-conditioning system evaluation, and a building envelope survey. In addition to air sampling, a human health risk assessment was performed to evaluate the potential for exposure to site-related air contaminants with respect to the inmate and worker populations. The risk assessment results for the prison facility indicated the potential for significant health risks for the inmate population, possibly reflecting the effects of their confinement and extended exposure to indoor air contaminants, as compared to the prison guard and worker population. Based on the results of the risk assessment, several mitigation measures are recommended to minimize prison population health risks and improve indoor air quality at prison facilities.

  8. Risk assessment associated to possible concrete degradation of a near surface disposal facility

    NASA Astrophysics Data System (ADS)

    Capra, B.; Billard, Y.; Wacquier, W.; Gens, R.

    2013-07-01

    This article outlines a risk analysis of possible concrete degradation performed in the framework of the preparation of the Safety Report of ONDRAF/NIRAS, the Belgian Agency for Radioactive Waste and Enriched Fissile Materials, for the construction and operation of a near surface disposal facility of category A waste - short-lived low and intermediate level waste - in Dessel. The main degradation mechanism considered is the carbonation of different concrete components over different periods (from the building phase up to 2000 years), which induces corrosion of the rebars. A dedicated methodology mixing risk analysis and numerical modeling of concrete carbonation has been developed to assess the critical risks of the disposal facility at different periods. According to the results obtained, risk mapping was used to assess the impact of carbonation of concrete on the different components at the different stages. The most important risk is related to an extreme situation with complete removal of the earth cover and side embankment.

  9. Risk Assessment Terminology: Risk Communication Part 2

    PubMed Central

    Bentley, Stefano; Giacometti, Federica; Piva, Silvia; Serraino, Andrea

    2016-01-01

    The paper describes the terminology of risk communication in the view of food safety: different aspects of risk perception (perceived risk, media triggers, the psychometric paradigm, fright factors and cultural determinants of risk perception) are described. The risk profile elements are illustrated in the manuscript: hazard-food commodity combination(s) of concern; description of the public health problem; food production, processing, distribution and consumption; needs and questions for the risk assessors; available information and major knowledge gaps and other risk profile elements. PMID:27800443

  10. Metrics for Success: Strategies for Enabling Core Facility Performance and Assessing Outcomes

    PubMed Central

    Hockberger, Philip E.; Meyn, Susan M.; Nicklin, Connie; Tabarini, Diane; Auger, Julie A.

    2016-01-01

    Core Facilities are key elements in the research portfolio of academic and private research institutions. Administrators overseeing core facilities (core administrators) require assessment tools for evaluating the need and effectiveness of these facilities at their institutions. This article discusses ways to promote best practices in core facilities as well as ways to evaluate their performance across 8 of the following categories: general management, research and technical staff, financial management, customer base and satisfaction, resource management, communications, institutional impact, and strategic planning. For each category, we provide lessons learned that we believe contribute to the effective and efficient overall management of core facilities. If done well, we believe that encouraging best practices and evaluating performance in core facilities will demonstrate and reinforce the importance of core facilities in the research and educational mission of institutions. It will also increase job satisfaction of those working in core facilities and improve the likelihood of sustainability of both facilities and personnel. PMID:26848284

  11. Metrics for Success: Strategies for Enabling Core Facility Performance and Assessing Outcomes.

    PubMed

    Turpen, Paula B; Hockberger, Philip E; Meyn, Susan M; Nicklin, Connie; Tabarini, Diane; Auger, Julie A

    2016-04-01

    Core Facilities are key elements in the research portfolio of academic and private research institutions. Administrators overseeing core facilities (core administrators) require assessment tools for evaluating the need and effectiveness of these facilities at their institutions. This article discusses ways to promote best practices in core facilities as well as ways to evaluate their performance across 8 of the following categories: general management, research and technical staff, financial management, customer base and satisfaction, resource management, communications, institutional impact, and strategic planning. For each category, we provide lessons learned that we believe contribute to the effective and efficient overall management of core facilities. If done well, we believe that encouraging best practices and evaluating performance in core facilities will demonstrate and reinforce the importance of core facilities in the research and educational mission of institutions. It will also increase job satisfaction of those working in core facilities and improve the likelihood of sustainability of both facilities and personnel.

  12. Human health risk characterization of petroleum coke calcining facility emissions.

    PubMed

    Singh, Davinderjit; Johnson, Giffe T; Harbison, Raymond D

    2015-12-01

    Calcining processes including handling and storage of raw petroleum coke may result in Particulate Matter (PM) and gaseous emissions. Concerns have been raised over the potential association between particulate and aerosol pollution and adverse respiratory health effects including decrements in lung function. This risk characterization evaluated the exposure concentrations of ambient air pollutants including PM10 and gaseous pollutants from a petroleum coke calciner facility. The ambient air pollutant levels were collected through monitors installed at multiple locations in the vicinity of the facility. The measured and modeled particulate levels in ambient air from the calciner facility were compared to standards protective of public health. The results indicated that exposure levels were, on occasions at sites farther from the facility, higher than the public health limit of 150 μg/m(3) 24-h average for PM10. However, the carbon fraction demonstrated that the contribution from the calciner facility was de minimis. Exposure levels of the modeled SO2, CO, NOx and PM10 concentrations were also below public health air quality standards. These results demonstrate that emissions from calcining processes involving petroleum coke, at facilities that are well controlled, are below regulatory standards and are not expected to produce a public health risk. Copyright © 2015 Elsevier Inc. All rights reserved.

  13. The physical vulnerability of elements at risk: a methodology based on fluid and classical mechanics

    NASA Astrophysics Data System (ADS)

    Mazzorana, B.; Fuchs, S.; Levaggi, L.

    2012-04-01

    The impacts of the flood events occurred in autumn 2011 in the Italian regions Liguria and Tuscany revived the engagement of the public decision makers to enhance in synergy flood control and land use planning. In this context, the design of efficient flood risk mitigation strategies and their subsequent implementation critically relies on a careful vulnerability analysis of both, the immobile and mobile elements at risk potentially exposed to flood hazards. Based on fluid and classical mechanics notions we developed computation schemes enabling for a dynamic vulnerability and risk analysis facing a broad typological variety of elements at risk. The methodological skeleton consists of (1) hydrodynamic computation of the time-varying flood intensities resulting for each element at risk in a succession of loading configurations; (2) modelling the mechanical response of the impacted elements through static, elasto-static and dynamic analyses; (3) characterising the mechanical response through proper structural damage variables and (4) economic valuation of the expected losses as a function of the quantified damage variables. From a computational perspective we coupled the description of the hydrodynamic flow behaviour and the induced structural modifications of the elements at risk exposed. Valuation methods, suitable to support a correct mapping from the value domains of the physical damage variables to the economic loss values are discussed. In such a way we target to complement from a methodological perspective the existing, mainly empirical, vulnerability and risk assessment approaches to refine the conceptual framework of the cost-benefit analysis. Moreover, we aim to support the design of effective flood risk mitigation strategies by diminishing the main criticalities within the systems prone to flood risk.

  14. 49 CFR 1155.27 - Board determinations under 49 U.S.C. 10909.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... determines that the facility at the existing or proposed location would not pose an unreasonable risk to... risk to public health, safety, or the environment, the Board shall weigh the particular facility's... comply with an environmental, public health, or public safety standard that falls under the traditional...

  15. Guidelines for Automatic Data Processing Physical Security and Risk Management. Federal Information Processing Standards Publication 31.

    ERIC Educational Resources Information Center

    National Bureau of Standards (DOC), Washington, DC.

    These guidelines provide a handbook for use by federal organizations in structuring physical security and risk management programs for their automatic data processing facilities. This publication discusses security analysis, natural disasters, supporting utilities, system reliability, procedural measures and controls, off-site facilities,…

  16. Webinar Presentation: Environmental Exposures and Health Risks in California Child Care Facilities: First Steps to Improve Environmental Health where Children Spend Time

    EPA Pesticide Factsheets

    This presentation, Environmental Exposures and Health Risks in California Child Care Facilities: First Steps to Improve Environmental Health where Children Spend Time, was given at the NIEHS/EPA Children's Centers 2016 Webinar Series: Exposome.

  17. Mistreatment in Assisted Living Facilities: Complaints, Substantiations, and Risk Factors

    ERIC Educational Resources Information Center

    Phillips, Linda R.; Guo, Guifang

    2011-01-01

    Purpose of the Study: Use archived public data from Arizona to explore relationships among selected institutional and resident risk and situation-specific factors and complaints and substantiated allegations of various types of mistreatment in assisted living facilities (ALFs). Design and Methods: An exploratory/descriptive 2-group design was…

  18. THE USEPA'S METAL FINISHING FACILITY RISK SCREENING TOOL (MFFRST) AND POLLUTION PREVENTION TOOL (MFFP2T)

    EPA Science Inventory

    This presentation will provide an overview of the USEPA's Metal Finishing Facility Risk Screening Tool, including a discussion of the models used and outputs. The tool is currently being expanded to include pollution prevention considerations as part of the model. The current st...

  19. Hazardous waste management system design under population and environmental impact considerations.

    PubMed

    Yilmaz, Ozge; Kara, Bahar Y; Yetis, Ulku

    2017-12-01

    This paper presents a multi objective mixed integer location/routing model that aims to minimize transportation cost and risks for large-scale hazardous waste management systems (HWMSs). Risks induced by hazardous wastes (HWs) on both public and the environment are addressed. For this purpose, a new environmental impact definition is proposed that considers the environmentally vulnerable elements including water bodies, agricultural areas, coastal regions and forestlands located within a certain bandwidth around transportation routes. The solution procedure yields to Pareto optimal curve for two conflicting objectives. The conceptual model developed prior to mathematical formulation addresses waste-to-technology compatibility and HW processing residues to assure applicability of the model to real-life HWMSs. The suggested model was used in a case study targeting HWMS in Turkey. Based on the proposed solution, it was possible to identify not only the transportation routes but also a set of information on HW handling facilities including the types, locations, capacities, and investment/operational cost. The HWMS of this study can be utilized both by public authorities and private sector investors for planning purposes. Copyright © 2016 Elsevier Ltd. All rights reserved.

  20. Hanford Site Asbestos Abatement Plan. Revision 1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mewes, B.S.

    The Hanford Site Asbestos Abatement Plan (Plan) lists priorities for asbestos abatement activities to be conducted in Hanford Site facilities. The Plan is based on asbestos assessment information gathered in fiscal year 1989 that evaluated all Hanford Site facilities for the presence and condition of asbestos. Of those facilities evaluated, 414 contain asbestos-containing materials and are classified according to the potential risk of asbestos exposure to building personnel. The Plan requires that asbestos condition update reports be prepared for all affected facilities. The reporting is completed by the asbestos coordinator for each of the 414 affected facilities and transmitted tomore » the Plan manager annually. The Plan manager uses this information to reprioritize future project lists. Currently, five facilities are determined to be Class Al, indicating a high potential for asbestos exposure. Class Al and B1 facilities are the highest priority for asbestos abatement. Abatement of the Class A1 and Bl facilities is scheduled through fiscal year 1997. Removal of asbestos in B1 facilities will reduce the risk for further Class ``A`` conditions to arise.« less

  1. Safety analysis, risk assessment, and risk acceptance criteria

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jamali, K.; Stack, D.W.; Sullivan, L.H.

    1997-08-01

    This paper discusses a number of topics that relate safety analysis as documented in the Department of Energy (DOE) safety analysis reports (SARs), probabilistic risk assessments (PRA) as characterized primarily in the context of the techniques that have assumed some level of formality in commercial nuclear power plant applications, and risk acceptance criteria as an outgrowth of PRA applications. DOE SARs of interest are those that are prepared for DOE facilities under DOE Order 5480.23 and the implementing guidance in DOE STD-3009-94. It must be noted that the primary area of application for DOE STD-3009 is existing DOE facilities andmore » that certain modifications of the STD-3009 approach are necessary in SARs for new facilities. Moreover, it is the hazard analysis (HA) and accident analysis (AA) portions of these SARs that are relevant to the present discussions. Although PRAs can be qualitative in nature, PRA as used in this paper refers more generally to all quantitative risk assessments and their underlying methods. HA as used in this paper refers more generally to all qualitative risk assessments and their underlying methods that have been in use in hazardous facilities other than nuclear power plants. This discussion includes both quantitative and qualitative risk assessment methods. PRA has been used, improved, developed, and refined since the Reactor Safety Study (WASH-1400) was published in 1975 by the Nuclear Regulatory Commission (NRC). Much debate has ensued since WASH-1400 on exactly what the role of PRA should be in plant design, reactor licensing, `ensuring` plant and process safety, and a large number of other decisions that must be made for potentially hazardous activities. Of particular interest in this area is whether the risks quantified using PRA should be compared with numerical risk acceptance criteria (RACs) to determine whether a facility is `safe.` Use of RACs requires quantitative estimates of consequence frequency and magnitude.« less

  2. Application of the API/NPRA SVA methodology to transportation security issues.

    PubMed

    Moore, David A

    2006-03-17

    Security vulnerability analysis (SVA) is becoming more prevalent as the issue of chemical process security is of greater concern. The American Petroleum Institute (API) and the National Petrochemical and Refiner's Association (NPRA) have developed a guideline for conducting SVAs of petroleum and petrochemical facilities in May 2003. In 2004, the same organizations enhanced the guidelines by adding the ability to evaluate transportation security risks (pipeline, truck, and rail). The importance of including transportation and value chain security in addition to fixed facility security in a SVA is that these issues may be critically important to understanding the total risk of the operation. Most of the SVAs done using the API/NPRA SVA and other SVA methods were centered on the fixed facility and the operations within the plant fence. Transportation interfaces alone are normally studied as a part of the facility SVA, and the entire transportation route impacts and value chain disruption are not commonly considered. Particularly from a national, regional, or local infrastructure analysis standpoint, understanding the interdependencies is critical to the risk assessment. Transportation risks may include weaponization of the asset by direct attack en route, sabotage, or a Trojan Horse style attack into a facility. The risks differ in the level of access control and the degree of public exposures, as well as the dynamic nature of the assets. The public exposures along the transportation route need to be carefully considered. Risks may be mitigated by one of many strategies including internment, staging, prioritization, conscription, or prohibition, as well as by administrative security measures and technology for monitoring and isolating the assets. This paper illustrates how these risks can be analyzed by the API/NPRA SVA methodology. Examples are given of a pipeline operation, and other examples are found in the guidelines.

  3. [Harm related to medical device use - legal and organisational risks].

    PubMed

    Hölscher, U M

    2014-12-01

    The effectiveness of the risk management systems established by medical device manufacturers and health-care facilities is clearly mitigated by European and national legal provisions. Laws, regulations and authorities prevent the systematic exchange of much safety-relevant information. The obligation to report adverse events is suspended for many relevant risks associated with medical device use. Reporting into the vigilance system is of little avail for users. Reporting even may endanger the information provider. The federal fragmentation of the German vigilance system poses a risk for patients. Risk management in health-care facilities without risk policy is dangerously incomplete. © Georg Thieme Verlag KG Stuttgart · New York.

  4. LSST summit facility construction progress report: reacting to design refinements and field conditions

    NASA Astrophysics Data System (ADS)

    Barr, Jeffrey D.; Gressler, William; Sebag, Jacques; Seriche, Jaime; Serrano, Eduardo

    2016-07-01

    The civil work, site infrastructure and buildings for the summit facility of the Large Synoptic Survey Telescope (LSST) are among the first major elements that need to be designed, bid and constructed to support the subsequent integration of the dome, telescope, optics, camera and supporting systems. As the contracts for those other major subsystems now move forward under the management of the LSST Telescope and Site (T and S) team, there has been inevitable and beneficial evolution in their designs, which has resulted in significant modifications to the facility and infrastructure. The earliest design requirements for the LSST summit facility were first documented in 2005, its contracted full design was initiated in 2010, and construction began in January, 2015. During that entire development period, and extending now roughly halfway through construction, there continue to be necessary modifications to the facility design resulting from the refinement of interfaces to other major elements of the LSST project and now, during construction, due to unanticipated field conditions. Changes from evolving interfaces have principally involved the telescope mount, the dome and mirror handling/coating facilities which have included significant variations in mass, dimensions, heat loads and anchorage conditions. Modifications related to field conditions have included specifying and testing alternative methods of excavation and contending with the lack of competent rock substrate where it was predicted to be. While these and other necessary changes are somewhat specific to the LSST project and site, they also exemplify inherent challenges related to the typical timeline for the design and construction of astronomical observatory support facilities relative to the overall development of the project.

  5. Requirements based system risk modeling

    NASA Technical Reports Server (NTRS)

    Meshkat, Leila; Cornford, Steven; Feather, Martin

    2004-01-01

    The problem that we address in this paper is assessing the expected degree of success of the system or mission based on the degree to which each requirement is satisfied and the relative weight of the requirements. We assume a complete list of the requirements, the relevant risk elements and their probability of occurrence and the quantified effect of the risk elements on the requirements. In order to assess the degree to which each requirement is satisfied, we need to determine the effect of the various risk elements on the requirement.

  6. INCINERATION RESEARCH FACILITY

    EPA Science Inventory

    The Cincinnati-based Risk Reduction Engineering Laboratory, ORD, U.S. EPA operates the Incineration Research Facility *IRF) in Jefferson, Arkansas. This facility's pilot-scale experimental incineration systems include a Rotary Kiln System and a Liquid Injection System. Each syste...

  7. Estimating earthquake-induced failure probability and downtime of critical facilities.

    PubMed

    Porter, Keith; Ramer, Kyle

    2012-01-01

    Fault trees have long been used to estimate failure risk in earthquakes, especially for nuclear power plants (NPPs). One interesting application is that one can assess and manage the probability that two facilities - a primary and backup - would be simultaneously rendered inoperative in a single earthquake. Another is that one can calculate the probabilistic time required to restore a facility to functionality, and the probability that, during any given planning period, the facility would be rendered inoperative for any specified duration. A large new peer-reviewed library of component damageability and repair-time data for the first time enables fault trees to be used to calculate the seismic risk of operational failure and downtime for a wide variety of buildings other than NPPs. With the new library, seismic risk of both the failure probability and probabilistic downtime can be assessed and managed, considering the facility's unique combination of structural and non-structural components, their seismic installation conditions, and the other systems on which the facility relies. An example is offered of real computer data centres operated by a California utility. The fault trees were created and tested in collaboration with utility operators, and the failure probability and downtime results validated in several ways.

  8. Effectiveness of an automatic manual wheelchair braking system in the prevention of falls.

    PubMed

    Martorello, Laura; Swanson, Edward

    2006-01-01

    The purpose of this study was to evaluate the effectiveness of an automatic manual wheelchair braking system in the reduction of falls for patients at high risk of falls while transferring to and from a manual wheelchair. The study design was a normative survey carried out through the use of a written questionnaire sent to 60 skilled nursing facilities to collect data from the medical charts, which identified patients at high risk for falls who used an automatic wheelchair braking system. The facilities participating in the study identified a frequency of falls of high-risk patients while transferring to and from the wheelchair ranging from 2 to 10 per year, with a median fall rate per facility of 4 falls. One year after the installation of the automatic wheelchair braking system, participating facilities demonstrated a reduction of zero to three falls during transfers by high-risk patients, with a median fall rate of zero falls. This represents a statistically significant reduction of 78% in the fall rate of high-risk patients while transferring to and from the wheelchair, t (18) = 6.39, p < .0001. Incident reports of falls to and from manual wheelchairs were reviewed retrospectively for a 1-year period. This study suggests that high-risk fallers transferring to or from manual wheelchairs sustained significantly fewer falls when the Steddy Mate automatic braking system for manual wheelchairs was installed. The application of the automatic braking system allows clients, families/caregivers, and facility personnel an increased safety factor for the reduction of falls from the wheelchair.

  9. Suicide risk in long-term care facilities: a systematic review.

    PubMed

    Mezuk, Briana; Rock, Andrew; Lohman, Matthew C; Choi, Moon

    2014-12-01

    Suicide risk is highest in later life; however, little is known about the risk of suicide among older adults in long-term care facilities (e.g., nursing homes and assisted living facilities). The goal of this paper is to review and synthesize the descriptive and analytic epidemiology of suicide in long-term care settings over the past 25 years. Four databases (PubMed, CINAHL Plus, Web of Knowledge, and EBSCOHost Academic Search Complete) were searched for empirical studies of suicide risk in nursing homes, assisted living, and other residential facilities from 1985 to 2013. Of the 4073 unique research articles identified, 37 were selected for inclusion in this review. Of the included reports, 21 were cross-sectional, 8 cohort, 3 qualitative, and 5 intervention studies. Most studies indicate that suicidal thoughts (active and passive) are common among residents (prevalence in the past month: 5-33%), although completed suicide is rare. Correlates of suicidal thoughts among long-term care residents include depression, social isolation, loneliness, and functional decline. Most studies examined only individual-level correlates of suicide, although there is suggestive evidence that organizational characteristics (e.g., bed size and staffing) may also be relevant. Existing research on suicide risk in long-term care facilities is limited but suggests that this is an important issue for clinicians and medical directors to be aware of and address. Research is needed on suicide risk in assisted living and other non-nursing home residential settings, as well as the potential role of organizational characteristics on emotional well-being for residents. Copyright © 2014 John Wiley & Sons, Ltd.

  10. Suicide risk in long-term care facilities: A systematic review

    PubMed Central

    Mezuk, Briana; Rock, Andrew; Lohman, Matthew C.; Choi, Moon

    2014-01-01

    Objective Suicide risk is highest in later life, however, little is known about the risk of suicide among older adults in long-term care facilities (e.g., nursing homes, assisted living facilities). The goal of this paper is to review and synthesize the descriptive and analytic epidemiology of suicide in long-term care settings over the past 25 years. Methods Four databases (PubMed, CINAHL Plus, Web of Knowledge, and EBSCOHost) were searched for empirical studies of suicide risk in nursing homes, assisted living, and other residential facilities from 1985 to 2013. Of the 4,073 unique research articles identified, 36 were selected for inclusion in this review. Results Of the included reports, 20were cross-sectional, 10 were longitudinal, three qualitative, and five were intervention studies. Most studies indicate that suicidal thoughts (active and passive) are common among residents (prevalence in the past month: 5 – 33%), although completed suicide is rare. Correlates of suicidal thoughts among long-term care residents include depression, social isolation, loneliness, and functional decline. Most studies examined only individual-level correlates of suicide, although there is suggestive evidence that organizational characteristics (e.g., bed size, staffing) may also be relevant. Conclusions Existing research on suicide risk in long-term care facilities is limited, but suggests that this is an important issue for clinicians and medical directors to be aware of and address. Research is needed on suicide risk in assisted living and other non-nursing home residential settings, as well as the potential role of organizational characteristics on emotional well-being for residents. PMID:24854089

  11. Comparison of elemental composition in two wild and cultured marine fish and potential risks to human health.

    PubMed

    Marengo, Michel; Durieux, Eric D H; Ternengo, Sonia; Lejeune, Pierre; Degrange, Elise; Pasqualini, Vanina; Gobert, Sylvie

    2018-08-30

    Among all available species, fish are a powerful model for risk-benefit assessments to study the effects of contaminants on human health. Gilthead seabream (Sparus aurata, Linnaeus 1758) and european seabass (Dicentrarchus labrax, Linnaeus 1758) are two species of great economic importance, representing very large production volumes in the Mediterranean. The objective of this study is (1) to analyze the concentrations of Trace Elements (TE) between wild and cultured seabream and seabass specimens, (2) to compare the determined concentrations with other studies, and (3) to increase the data about the potential risks to human health. Our results point to significant intra- and interspecies-specific differences between wild and cultured fish for several trace elements. Several strong and moderate inter-elemental correlations in fish muscle were observed through correlation analysis. In our study, the mean levels of trace elements were still below the standard safety values for fish intended for human consumption. The same results were reached for all the parameters analyzed (international legal limits, estimated weekly intake, provisional tolerable weekly intake, target hazard quotient, target cancer risk), with trace element levels in fish below those that could pose a risk to human health. Consequently, these fish can be considered safe for human consumption. A better understanding of the levels of trace elements in fish would also better inform consumers about the potential risks of exposure to contaminants. Copyright © 2018 Elsevier Inc. All rights reserved.

  12. NSR&D Program Fiscal Year (FY) 2015 Call for Proposals Mitigation of Seismic Risk at Nuclear Facilities using Seismic Isolation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Coleman, Justin

    2015-02-01

    Seismic isolation (SI) has the potential to drastically reduce seismic response of structures, systems, or components (SSCs) and therefore the risk associated with large seismic events (large seismic event could be defined as the design basis earthquake (DBE) and/or the beyond design basis earthquake (BDBE) depending on the site location). This would correspond to a potential increase in nuclear safety by minimizing the structural response and thus minimizing the risk of material release during large seismic events that have uncertainty associated with their magnitude and frequency. The national consensus standard America Society of Civil Engineers (ASCE) Standard 4, Seismic Analysismore » of Safety Related Nuclear Structures recently incorporated language and commentary for seismically isolating a large light water reactor or similar large nuclear structure. Some potential benefits of SI are: 1) substantially decoupling the SSC from the earthquake hazard thus decreasing risk of material release during large earthquakes, 2) cost savings for the facility and/or equipment, and 3) applicability to both nuclear (current and next generation) and high hazard non-nuclear facilities. Issue: To date no one has evaluated how the benefit of seismic risk reduction reduces cost to construct a nuclear facility. Objective: Use seismic probabilistic risk assessment (SPRA) to evaluate the reduction in seismic risk and estimate potential cost savings of seismic isolation of a generic nuclear facility. This project would leverage ongoing Idaho National Laboratory (INL) activities that are developing advanced (SPRA) methods using Nonlinear Soil-Structure Interaction (NLSSI) analysis. Technical Approach: The proposed study is intended to obtain an estimate on the reduction in seismic risk and construction cost that might be achieved by seismically isolating a nuclear facility. The nuclear facility is a representative pressurized water reactor building nuclear power plant (NPP) structure. Figure 1: Project activities The study will consider a representative NPP reinforced concrete reactor building and representative plant safety system. This study will leverage existing research and development (R&D) activities at INL. Figure 1 shows the proposed study steps with the steps in blue representing activities already funded at INL and the steps in purple the activities that would be funded under this proposal. The following results will be documented: 1) Comparison of seismic risk for the non-seismically isolated (non-SI) and seismically isolated (SI) NPP, and 2) an estimate of construction cost savings when implementing SI at the site of the generic NPP.« less

  13. Evaluation of biodiesel’s impact on real-world occupational and environmental particulate matter exposures at a municipal facility in Keene, NH

    PubMed Central

    Thelen, Brett Amy; Ingalls, Jaime Kathryn; Treadwell, Melinda Dawn

    2016-01-01

    Many organizations are interested in biodiesel as a renewable, domestic energy source for use in transportation and heavy-duty equipment. Although numerous biodiesel emission studies exist, biodiesel exposure studies are nearly absent from the literature. This study compared the impact of petroleum diesel fuel and a B20 blend (20% soy-based biodiesel/80% petroleum diesel) on occupational and environmental exposures at a rural municipal facility in Keene, NH. For each fuel type, we measured concentrations of fine particulate matter (PM2.5), elemental carbon (EC), and organic carbon (OC) at multiple locations (in-cabin, work area, and near-field) at a materials recovery facility utilizing non-road equipment. B20 fuel use resulted in significant reductions in PM2.5 mass (56–76%), reductions in EC (5–29%), and increases in OC (294–467%). Concentrations of PM2.5 measured during petroleum diesel use were up to four times higher than PM2.5 concentrations during B20 use. Further analysis of the EC and OC fractions of total carbon also indicated substantial differences between fuels. Our results demonstrate that biodiesel blends significantly reduced PM2.5 exposure compared to petroleum diesel fuel in a workplace utilizing non-road construction-type equipment. While this suggests that biodiesel may reduce health risks associated with exposure to fine particulate matter mass, more exposure research is needed to better understand biodiesel-related changes in particulate matter composition and other exposure metrics.

  14. Exposure and Emissions Monitoring during Carbon Nanofiber Production—Part I: Elemental Carbon and Iron–Soot Aerosols

    PubMed Central

    Birch, M. Eileen; Ku, Bon-Ki; Evans, Douglas E.; Ruda-Eberenz, Toni A.

    2015-01-01

    Production of carbon nanofibers and nanotubes (CNFs/CNTs) and their composite products is increasing globally. High volume production may increase the exposure risks for workers who handle these materials. Though health effects data for CNFs/CNTs are limited, some studies raise serious health concerns. Given the uncertainty about their potential hazards, there is an immediate need for toxicity data and field studies to assess exposure to CNFs/CNTs. An extensive study was conducted at a facility that manufactures and processes CNFs. Filter, sorbent, cascade impactor, bulk, and microscopy samples, combined with direct-reading instruments, provided complementary information on air contaminants. Samples were analyzed for organic carbon (OC) and elemental carbon (EC), metals, and polycyclic aromatic hydrocarbons (PAHs), with EC as a measure of CNFs. Transmission electron microscopy with energy-dispersive X-ray spectroscopy also was applied. Fine/ultrafine iron-rich soot, PAHs, and carbon monoxide were production byproducts. Direct-reading instrument results were reported previously [Evans DE et al. (Aerosol monitoring during carbon nanofiber production: mobile direct-reading sampling. Ann Occup Hyg 2010;54:514–31.)] Results for time-integrated samples are reported as companion papers in this Issue. OC and EC, metals, and microscopy results are reported here, in Part I, while results for PAHs are reported in Part II [Birch ME. (Exposure and Emissions Monitoring during Carbon Nanofiber Production—Part II: Polycyclic Aromatic Hydrocarbons. Ann. Occup. Hyg 2011; 55: 1037–47.)]. Respirable EC area concentrations inside the facility were about 6–68 times higher than outdoors, while personal breathing zone samples were up to 170 times higher. PMID:21965464

  15. Study protocol: the Adherence and Intensification of Medications (AIM) study--a cluster randomized controlled effectiveness study.

    PubMed

    Heisler, Michele; Hofer, Timothy P; Klamerus, Mandi L; Schmittdiel, Julie; Selby, Joe; Hogan, Mary M; Bosworth, Hayden B; Tremblay, Adam; Kerr, Eve A

    2010-10-12

    Many patients with diabetes have poor blood pressure (BP) control. Pharmacological therapy is the cornerstone of effective BP treatment, yet there are high rates both of poor medication adherence and failure to intensify medications. Successful medication management requires an effective partnership between providers who initiate and increase doses of effective medications and patients who adhere to the regimen. In this cluster-randomized controlled effectiveness study, primary care teams within sites were randomized to a program led by a clinical pharmacist trained in motivational interviewing-based behavioral counseling approaches and authorized to make BP medication changes or to usual care. This study involved the collection of data during a 14-month intervention period in three Department of Veterans Affairs facilities and two Kaiser Permanente Northern California facilities. The clinical pharmacist was supported by clinical information systems that enabled proactive identification of, and outreach to, eligible patients identified on the basis of poor BP control and either medication refill gaps or lack of recent medication intensification. The primary outcome is the relative change in systolic blood pressure (SBP) measurements over time. Secondary outcomes are changes in Hemoglobin A1c, low-density lipoprotein cholesterol (LDL), medication adherence determined from pharmacy refill data, and medication intensification rates. Integration of the three intervention elements--proactive identification, adherence counseling and medication intensification--is essential to achieve optimal levels of control for high-risk patients. Testing the effectiveness of this intervention at the team level allows us to study the program as it would typically be implemented within a clinic setting, including how it integrates with other elements of care. The ClinicalTrials.gov registration number is NCT00495794.

  16. Integration of site-specific health information: Agency for Toxic Substances and Disease Registry health assessments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lesperance, A.M.; Siegel, M.R.

    The Agency for Toxic Substances and Disease Registry is required to conduct a health assessment of any site that is listed on or proposed for the US Environmental Protection Agency's National Priorities List. Sixteen US Department of Energy (DOE) sites currently fall into this category. Health assessments contain a qualitative description of impacts to public health and the environment from hazardous waste sites, as well as recommendations for actions to mitigate or eliminate risk. Because these recommendations may have major impacts on compliance activities at DOE facilities, the health assessments are an important source of information for the monitoring activitiesmore » of DOE's Office of Environmental Compliance (OEC). This report provides an overview of the activities involved in preparing the health assessment, its role in environmental management, and its key elements.« less

  17. Experimental facility for testing nuclear instruments for planetary landing missions

    NASA Astrophysics Data System (ADS)

    Golovin, Dmitry; Mitrofanov, Igor; Litvak, Maxim; Kozyrev, Alexander; Sanin, Anton; Vostrukhin, Andrey

    2017-04-01

    The experimental facility for testing and calibration of nuclear planetology instruments has been built in the frame of JINR and Space Research Institute (Moscow) cooperation. The Martian soil model from silicate glass with dimensions 3.82 x 3.21 m and total weight near 30 tons has been assembled in the facility. The glass material was chosen for imitation of dry Martian regolith. The heterogeneous model has been proposed and developed to achieve the most possible similarity with Martian soil in part of the average elemental composition by adding layers of necessary materials, such as iron, aluminum, and chlorine. The presence of subsurface water ice is simulated by adding layers of polyethylene at different depths inside glass model assembly. Neutron generator was used as a neutron source to induce characteristic gamma rays for testing active neutron and gamma spectrometers to define elements composition of the model. The instrumentation was able to detect gamma lines attributed to H, O, Na, Mg, Al, Si, Cl, K, Ca and Fe. The identified elements compose up to 95 wt % of total mass of the planetary soil model. This results will be used for designing scientific instruments to performing experiments of active neutron and gamma ray spectroscopy on the surface of the planets during Russian and international missions Luna-Glob, Luna-Resource and ExoMars-2020.

  18. Development of a tritium recovery system from CANDU tritium removal facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Draghia, M.; Pasca, G.; Porcariu, F.

    2015-03-15

    The main purpose of the Tritium Recovery System (TRS) is to reduce to a maximum possible extent the release of tritium from the facility following a tritium release in confinement boundaries and also to have provisions to recover both elemental and vapors tritium from the purging gases during maintenance and components replacement from various systems processing tritium. This work/paper proposes a configuration of Tritium Recovery System wherein elemental tritium and water vapors are recovered in a separated, parallel manner. The proposed TRS configuration is a combination of permeators, a platinum microreactor (MR) and a trickle bed reactor (TBR) and consistsmore » of two branches: one branch for elemental tritium recovery from tritiated deuterium gas and the second one for tritium recovery from streams containing a significant amount of water vapours but a low amount, below 5%, of tritiated gas. The two branches shall work in a complementary manner in such a way that the bleed stream from the permeators shall be further processed in the MR and TBR in view of achieving the required decontamination level. A preliminary evaluation of the proposed TRS in comparison with state of the art tritium recovery system from tritium processing facilities is also discussed. (authors)« less

  19. Development of an integrated transuranic waste management system for a large research facility: NUCEF

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mineo, Hideaki; Matsumura, Tatsuro; Takeshita, Isao

    1997-03-01

    The Nuclear Fuel Cycle Safety Engineering Research Facility (NUCEF) is a large complex of research facilities where transuranic (TRU) elements are used. Liquid and solid waste containing TRU elements is generated mainly in the treatment of fuel for critical experiments and in the research of reprocessing and TRU waste management in hot cells and glove boxes. The rational management of TRU wastes is a very important issue not only for NUCEF but also for Japan. An integrated TRU waste management system is being developed with NUCEF as the test bed. The basic policy for establishing the system is to classifymore » wastes by TRU concentration, to reduce waste volume, and to maximize reuse of TRU elements. The principal approach of the development program is to apply the outcomes of the research carried out in NUCEF. Key technologies are TRU measurement for classification of solid wastes and TRU separation and volume reduction for organic and aqueous wastes. Some technologies required for treating the wastes specific to the research activities in NUCEF need further development. Specifically, the separation and stabilization technologies for americium recovery from concentrated aqueous waste, which is generated in dissolution of mixed oxide when preparing fuel for critical experiments, needs further research.« less

  20. A Site Characterization Protocol for Evaluating the Potential for Triggered or Induced Seismicity Resulting from Wastewater Injection and Hydraulic Fracturing

    NASA Astrophysics Data System (ADS)

    Walters, R. J.; Zoback, M. D.; Gupta, A.; Baker, J.; Beroza, G. C.

    2014-12-01

    Regulatory and governmental agencies, individual companies and industry groups and others have recently proposed, or are developing, guidelines aimed at reducing the risk associated with earthquakes triggered by waste water injection or hydraulic fracturing. While there are a number of elements common to the guidelines proposed, not surprisingly, there are also some significant differences among them and, in a number of cases, important considerations that are not addressed. The goal of this work is to develop a comprehensive protocol for site characterization based on a rigorous scientific understanding of the responsible processes. Topics addressed will include the geologic setting (emphasizing faults that might be affected), historical seismicity, hydraulic characterization of injection and adjacent intervals, geomechanical characterization to identify potentially active faults, plans for seismic monitoring and reporting, plans for monitoring and reporting injection (pressure, volumes, and rates), other factors contributing to risk (potentially affected population centers, structures, and facilities), and implementing a modified Probabilistic Seismic Hazard Analysis (PSHA). The guidelines will be risk based and adaptable, rather than prescriptive, for a proposed activity and region of interest. They will be goal oriented and will rely, to the degree possible, on established best practice procedures, referring to existing procedures and recommendations. By developing a risk-based site characterization protocol, we hope to contribute to the development of rational and effective measures for reducing the risk posed by activities that potentially trigger earthquakes.

  1. Expanding the Crisis Planning Function: Introducing Elements of Risk Communication to Crisis Communication Practice.

    ERIC Educational Resources Information Center

    Williams, David E.; Olaniran, Bolanle A.

    1998-01-01

    Suggests use of elements of risk communication by crisis communication practitioners facing increasing industrial reliance on new technologies which might be associated with potential health/environment harm. Studies a small company crisis which reveals that elements of anticipation, public involvement/trust, technological comparison, and media…

  2. Assessment of radiological protection systems among diagnostic radiology facilities in North East India.

    PubMed

    Singh, Thokchom Dewan; Jayaraman, T; Arunkumar Sharma, B

    2017-03-01

    This study aims to assess the adequacy level of radiological protection systems available in the diagnostic radiology facilities located in three capital cities of North East (NE) India. It further attempts to understand, using a multi-disciplinary approach, how the safety codes/standards in diagnostic radiology framed by the Atomic Energy Regulatory Board (AERB) and the International Atomic Energy Agency (IAEA) to achieve adequate radiological protection in facilities, have been perceived, conceptualized, and applied accordingly in these facilities. About 30 diagnostic radiology facilities were randomly selected from three capitals of states in NE India; namely Imphal (Manipur), Shillong (Meghalaya) and Guwahati (Assam). A semi-structured questionnaire developed based on a multi-disciplinary approach was used for this study. It was observed that radiological practices undertaken in these facilities were not exactly in line with safety codes/standards in diagnostic radiology of the AERB and the IAEA. About 50% of the facilities had registered/licensed x-ray equipment with the AERB. More than 80% of the workers did not use radiation protective devices, although these devices were available in the facilities. About 85% of facilities had no institutional risk management system. About 70% of the facilities did not carry out periodic quality assurance testing of their x-ray equipment or surveys of radiation leakage around the x-ray room, and did not display radiation safety indicators in the x-ray rooms. Workers in these facilities exhibited low risk perception about the risks associated with these practices. The majority of diagnostic radiology facilities in NE India did not comply with the radiological safety codes/standards framed by the AERB and IAEA. The study found inadequate levels of radiological protection systems in the majority of facilities. This study suggests a need to establish firm measures that comply with the radiological safety codes/standards of the AERB and IAEA to protect patients, workers and the public of this region.

  3. Analyses in Support of Risk-Informed Natural Gas Vehicle Maintenance Facility Codes and Standards: Phase II.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Blaylock, Myra L.; LaFleur, Chris Bensdotter; Muna, Alice Baca

    Safety standards development for maintenance facilities of liquid and compressed natural gas fueled vehicles is required to ensure proper facility design and operating procedures. Standard development organizations are utilizing risk-informed concepts to develop natural gas vehicle (NGV) codes and standards so that maintenance facilities meet acceptable risk levels. The present report summarizes Phase II work for existing NGV repair facility code requirements and highlights inconsistencies that need quantitative analysis into their effectiveness. A Hazardous and Operability study was performed to identify key scenarios of interest using risk ranking. Detailed simulations and modeling were performed to estimate the location and behaviormore » of natural gas releases based on these scenarios. Specific code conflicts were identified, and ineffective code requirements were highlighted and resolutions proposed. These include ventilation rate basis on area or volume, as well as a ceiling offset which seems ineffective at protecting against flammable gas concentrations. ACKNOWLEDGEMENTS The authors gratefully acknowledge Bill Houf (SNL -- Retired) for his assistance with the set-up and post-processing of the numerical simulations. The authors also acknowledge Doug Horne (retired) for his helpful discussions. We would also like to acknowledge the support from the Clean Cities program of DOE's Vehicle Technology Office.« less

  4. Water safety in healthcare facilities. The Vieste Charter.

    PubMed

    Bonadonna, L; Cannarozzi de Grazia, M; Capolongo, S; Casini, B; Cristina, M L; Daniele, G; D'Alessandro, D; De Giglio, O; Di Benedetto, A; Di Vittorio, G; Ferretti, E; Frascolla, B; La Rosa, G; La Sala, L; Lopuzzo, M G; Lucentini, L; Montagna, M T; Moscato, U; Pasquarella, C; Prencipe, R; Ricci, M L; Romano Spica, V; Signorelli, C; Veschetti, E

    2017-01-01

    The Study Group on Hospital Hygiene of the Italian Society of Hygiene, Preventive Medicine and Public Health (GISIO-SItI) and the Local Health Authority of Foggia, Apulia, Italy, after the National Convention "Safe water in healthcare facilities" held in Vieste-Pugnochiuso on 27-28 May 2016, present the "Vieste Charter", drawn up in collaboration with experts from the National Institute of Health and the Ministry of Health. This paper considers the risk factors that may affect the water safety in healthcare facilities and reports the current regulatory frameworks governing the management of installations and the quality of the water. The Authors promote a careful analysis of the risks that characterize the health facilities, for the control of which specific actions are recommended in various areas, including water safety plans; approval of treatments; healthcare facilities responsibility, installation and maintenance of facilities; multidisciplinary approach; education and research; regional and national coordination; communication.

  5. Automatic vertebral bodies detection of x-ray images using invariant multiscale template matching

    NASA Astrophysics Data System (ADS)

    Sharifi Sarabi, Mona; Villaroman, Diane; Beckett, Joel; Attiah, Mark; Marcus, Logan; Ahn, Christine; Babayan, Diana; Gaonkar, Bilwaj; Macyszyn, Luke; Raghavendra, Cauligi

    2017-03-01

    Lower back pain and pathologies related to it are one of the most common results for a referral to a neurosurgical clinic in the developed and the developing world. Quantitative evaluation of these pathologies is a challenge. Image based measurements of angles/vertebral heights and disks could provide a potential quantitative biomarker for tracking and measuring these pathologies. Detection of vertebral bodies is a key element and is the focus of the current work. From the variety of medical imaging techniques, MRI and CT scans have been typically used for developing image segmentation methods. However, CT scans are known to give a large dose of x-rays, increasing cancer risk [8]. MRI can be substituted for CTs when the risk is high [8] but are difficult to obtain in smaller facilities due to cost and lack of expertise in the field [2]. X-rays provide another option with its ability to control the x-ray dosage, especially for young people, and its accessibility for smaller facilities. Hence, the ability to create quantitative biomarkers from x-ray data is especially valuable. Here, we develop a multiscale template matching, inspired by [9], to detect centers of vertebral bodies from x-ray data. The immediate application of such detection lies in developing quantitative biomarkers and in querying similar images in a database. Previously, shape similarity classification methods have been used to address this problem, but these are challenging to use in the presence of variation due to gross pathology and even subtle effects [1].

  6. Microgravity research in NASA ground-based facilities

    NASA Technical Reports Server (NTRS)

    Lekan, Jack

    1989-01-01

    An overview of reduced gravity research performed in NASA ground-based facilities sponsored by the Microgravity Science and Applications Program of the NASA Office of Space Science and Applications is presented. A brief description and summary of the operations and capabilities of each of these facilities along with an overview of the historical usage of them is included. The goals and program elements of the Microgravity Science and Applications programs are described and the specific programs that utilize the low gravity facilities are identified. Results from two particular investigations in combustion (flame spread over solid fuels) and fluid physics (gas-liquid flows at microgravity conditions) are presented.

  7. The Microgravity Isolation Mount (MGIM): A Columbus facility for improving the microgravity quality of payloads

    NASA Technical Reports Server (NTRS)

    Owen, R. G.; Jones, D. I.; Owens, A. R.; Roberts, G.; Hadfield, P.

    1992-01-01

    The Microgravity Isolation Mount (MGIM) is a facility for providing active vibration isolation for sensitive experiments on the Columbus Attached Laboratory and the Columbus Free-Flying Laboratory. The facility is designed to be accommodated in a standard Columbus rack, and it iterfaces with existing rack utility services. The design is based on a non-contact strategy, whereby the payload 'floats' inside the rack, and its position is controlled by a number of magnetic actuators. The main advantage of using this non-contact strategy is the improved microgravity quality available. The overall design of the facility and a description of its elements are given.

  8. Spatial characterization, risk assessment, and statistical source identification of the dissolved trace elements in the Ganjiang River-feeding tributary of the Poyang Lake, China.

    PubMed

    Zhang, Hua; Jiang, Yinghui; Wang, Min; Wang, Peng; Shi, Guangxun; Ding, Mingjun

    2017-01-01

    Surface water samples were collected from 20 sampling sites throughout the Ganjiang River during pre-monsoon, monsoon, and post-monsoon seasons, and the concentrations of dissolved trace elements were determined by inductively coupled plasma-mass spectrometry (ICP-MS) for the spatial and seasonal variations, risk assessment, source identification, and categorization for risk area. The result demonstrated that concentrations of the elements exhibited significant seasonality. The high total element concentrations were detected at sites close to the intensive mining and urban activities. The concentrations of the elements were under the permissible limits as prescribed by related standards with a few exceptions. The most of heavy metal pollution index (HPI) values were lower than the critical index limit, indicating the basically clean water used as habitat for aquatic life. As was identified as the priority pollutant of non-carcinogenic and carcinogenic concerns, and the inhabitants ingesting the surface water at particular site might be subjected to the integrated health risks for exposure to the mixed trace elements. Multivariate statistical analyses confirmed that Zn, As, Cd, and Tl were derived from mining and urban activities; V, Cd, and Pb exhibited mixed origin; and Co, Ni, and Cu mainly resulted from natural processes. Three categorized risk areas corresponded to high, moderate, and low risks, respectively. As a whole, the upstream of the Ganjiang River was identified as the high-risk area relatively.

  9. DEVELOPMENT OF THE METAL FINISHING FACILITY RISK SCREENING TOOL

    EPA Science Inventory

    Enhancement of the US Environmental Protection Agency's
    Metal Finishing Facility Risk Screening Tool (MFFRST)

    William M. Barrett Jr, Ph.D., P.E. , P.E.; Paul Harten, Ph.D.1, Matt Lorber , Charles Peck , and Steve Schwartz, P.E., Q.E.P.3

    Recently, the US Environ...

  10. Risk and Resilience: Girls' Experiences Navigating Space and Relationships in a Secure Residential Facility

    ERIC Educational Resources Information Center

    Simonsen, Amy E.

    2010-01-01

    The purpose of this qualitative study was to examine how adolescent girls with diagnosed learning and emotional disabilities described themselves as they negotiated various environments and relationships within a secure residential facility. The goal was to explore how conditions and interactions in these environments promoted both risk and…

  11. Preliminary risk assessment for nuclear waste disposal in space, volume 2

    NASA Technical Reports Server (NTRS)

    Rice, E. E.; Denning, R. S.; Friedlander, A. L.

    1982-01-01

    Safety guidelines are presented. Waste form, waste processing and payload fabrication facilities, shipping casks and ground transport vehicles, payload primary container/core, radiation shield, reentry systems, launch site facilities, uprooted space shuttle launch vehicle, Earth packing orbits, orbit transfer systems, and space destination are discussed. Disposed concepts and risks are then discussed.

  12. Evaluating Potential Human Health Risks Associated with the Development of Utility-Scale Solar Energy Facilities on Contaminated Sites

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cheng, J. -J.; Chang, Y. -S.; Hartmann, H.

    2013-09-01

    This report presents a general methodology for obtaining preliminary estimates of the potential human health risks associated with developing a utility-scale solar energy facility on a contaminated site, based on potential exposures to contaminants in soils (including transport of those contaminants into the air).

  13. The initial electrocardiogram during admission for myocardial infarction. Use as a predictor of clinical course and facility utilization.

    PubMed

    Stark, M E; Vacek, J L

    1987-05-01

    The first electrocardiogram obtained on presentation for suspected myocardial infarction was examined for its usefulness in predicting clinical course and facility use. We studied 221 patients consecutively admitted to a nonuniversity hospital coronary care unit. High-risk patients were identified if the electrocardiographic diagnoses included myocardial infarction, ischemia, left ventricular hypertrophy, left bundle-branch block, or paced rhythm. These 63 patients (29% of total) had significantly greater incidences of serious events, need for procedures, and death than low-risk patients whose initial electrocardiograms did not carry the above diagnoses. Patients with a low-risk initial electrocardiogram may not require the facilities of a coronary care unit and perhaps could be safely observed in an intermediate care area. However, many hospitals do not have an intermediate care facility available, and in those that do, daily costs may not be markedly different than for treatment in a coronary care unit. Whether these low-risk patients could be safely treated in general medicine beds, where potential cost savings would be much greater, is unknown.

  14. Barriers to management of cardiovascular risk in a low-resource setting using hypertension as an entry point.

    PubMed

    Mendis, Shanthi; Abegunde, Dele; Oladapo, Olulola; Celletti, Francesca; Nordet, Porfirio

    2004-01-01

    Assess capacity of health-care facilities in a low-resource setting to implement the absolute risk approach for assessment of cardiovascular risk in hypertensive patients and effective management of hypertension. A descriptive cross-sectional study in Egbeda and Oluyole local government areas of Oyo State in Nigeria in 56 randomly selected primary- (n = 42) and secondary-level (n = 2) health-care and private health-care (n = 12) facilities. One thousand consecutive, known hypertensives attending the selected facilities for follow-up, and health-care providers working in the above randomly selected facilities, were interviewed. About two-thirds of hypertensives utilized primary-care centers both for diagnosis and for follow-up. Laboratory and other investigations to exclude secondary hypertension or to assess target organ damage were not available in the majority of facilities, particularly in primary care. A considerable knowledge and awareness gap related to hypertension and its complications was found, both among patients and health-care providers. Blood pressure control rates were poor (28% with systolic blood pressure (SBP) < 140 mmHg and diastolic blood pressure (DBP) < 90 mmHg] and drug prescription patterns were not evidence based and cost effective. The majority of patients (73%) in this low socio-economic group (mean monthly income 73 US dollars) had to pay fully, out of their own pocket, for consultations and medications. If the absolute risk approach for assessment of risk and effective management of hypertension is to be implemented in low-resource settings, appropriate policy measures need to be taken to improve the competency of health-care providers, to provide basic laboratory facilities and to develop affordable financing mechanisms.

  15. Element material experiment by EFFU

    NASA Technical Reports Server (NTRS)

    Hashimoto, Yoshihiro; Ichikawa, Masaaki; Takei, Mitsuru; Torii, Yoshihiro; Ota, Kazuo

    1995-01-01

    National Space Development Agency of JAPAN (NASDA) is planning to perform Element Material Exposure Experiment using Exposed Facility Flyer Unit (EFFU). Several materials which will be used on JEM (Japanese Experiment Module for the space station) will be exposed. Space environment monitoring is also planned in this experiment. Several ground based tests are now being performed and getting useful data.

  16. Toxicity and bioavailability of metals in the Missouri River adjacent to a lead refinery

    USGS Publications Warehouse

    Chapman, Duane C.; Allert, Ann L.; Fairchild, James F.; May, Thomas W.; Schmitt, Christopher J.; Callahan, Edward V.

    2001-01-01

    This study is an evaluation of the potential environmental impacts of contaminated groundwater from the ASARCO metals refining facility adjacent to the Missouri River in Omaha, Nebraska. Surface waters, sediments, and sediment pore waters were collected from the Burt-Izard drain, which transects the facility, and from the Missouri River adjacent to the facility. Groundwater was also collected from the facility. Waters and sediments were analyzed for inorganic contaminants, and the toxicity of the waters was evaluated with the Ceriodaphnia dubia 7-day test. Concentrations of several elemental contaminants were highly elevated in the groundwater, but not in river sediment pore waters. Lead concentrations were moderately elevated in whole sediment at one site, but lead concentrations in pore waters were low due to apparent sequestration by acid-volatile sulfides. The groundwater sample was highly toxic to C. dubia, causing 100% mortality. Even at the lowest groundwater concentration tested (6.25%) C. dubia survival was reduced; however, at that concentration, reproduction was not significantly different from upstream porewater reference samples. Sediment pore waters were not toxic, except reproduction in pore water collected from one downstream site was somewhat reduced. The decrease in reproduction could not be attributed to measured elemental contaminants.

  17. Discharge documentation of patients discharged to subacute facilities: a three-year quality improvement process across an integrated health care system.

    PubMed

    Gandara, Esteban; Ungar, Jonathan; Lee, Jason; Chan-Macrae, Myrna; O'Malley, Terrence; Schnipper, Jeffrey L

    2010-06-01

    Effective communication among physicians during hospital discharge is critical to patient care. Partners Healthcare (Boston) has been engaged in a multi-year process to measure and improve the quality of documentation of all patients discharged from its five acute care hospitals to subacute facilities. Partners first engaged stakeholders to develop a consensus set of 12 required data elements for all discharges to subacute facilities. A measurement process was established and later refined. Quality improvement interventions were then initiated to address measured deficiencies and included education of physicians and nurses, improvements in information technology, creation of or improvements in discharge documentation templates, training of hospitalists to serve as role models, feedback to physicians and their service chiefs regarding reviewed cases, and case manager review of documentation before discharge. To measure improvement in quality as a result of these efforts, rates of simultaneous inclusion of all 12 applicable data elements ("defect-free rate") were analyzed over time. Some 3,101 discharge documentation packets of patients discharged to subacute facilities from January 1, 2006, through September 2008 were retrospectively studied. During the 11 monitored quarters, the defect-free rate increased from 65% to 96% (p < .001 for trend). The largest improvements were seen in documentation of preadmission medication lists, allergies, follow-up, and warfarin information. Institution of rigorous measurement, feedback, and multidisciplinary, multimodal quality improvement processes improved the inclusion of data elements in discharge documentation required for safe hospital discharge across a large integrated health care system.

  18. Risk, media, and stigma at Rocky Flats

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Flynn, J.; Peters, E.; Mertz, C.K.

    1998-12-01

    Public responses to nuclear technologies are often strongly negative. Events, such as accidents or evidence of unsafe conditions at nuclear facilities, receive extensive and dramatic coverage by the news media. These news stories affect public perceptions of nuclear risks and the geographic areas near nuclear facilities. One result of these perceptions, avoidance behavior, is a form of technological stigma that leads to losses in property values near nuclear facilities. The social amplification of risk is a conceptual framework that attempts to explain how stigma is created through media transmission of information about hazardous places and public perceptions and decisions. Thismore » paper examines stigma associated with the US Department of energy`s Rocky Flats facility, a major production plant in the nation`s nuclear weapons complex, located near Denver, Colorado. This study, based upon newspaper analyses and a survey of Denver area residents, finds that the social amplification theory provides a reasonable framework for understanding the events and public responses that took place in regard to Rocky Flats during a 6-year period, beginning with an FBI raid of the facility in 1989.« less

  19. Use of personal protective equipment for respiratory protection.

    PubMed

    Sargent, Edward V; Gallo, Frank

    2003-01-01

    Management of hazards in biomedical research facilities requires the application of the traditional industrial hygiene responsibilities of anticipation, recognition, evaluation, and control to characterize the work environment, evaluate tasks and equipment, identify hazards, define exposure groups, and recommend controls. Generally, the diversity and unique characteristics of hazards faced by laboratory and animal facility employees and the short-term and low-level nature of the exposures factor into the selection of proper exposure control measures in the laboratory. The proper selection of control measures is based on a hierarchy of elimination and minimization by engineering controls, followed last by personal protective equipment when exposures cannot be eliminated. Once it is decided that personal protective equipment is needed, specific regulations and guidelines define safety standards for research facilities, including the elements of a sound respiratory protection program. These elements include respirator selection (including appropriate protection factors), medical evaluation, fit testing, training, inspection, maintenance and care, quality, quantity and flow of breathing air, and routine and emergency use procedures.

  20. Potential human health risk from consumption of metallic elements-contaminated benthic mollusks from Don Hoi Lot sandbar, Thailand.

    PubMed

    Khidkhan, Kraisiri; Imsilp, Kanjana; Poapolathep, Amnart; Poapolathep, Saranya; Tanhan, Phanwimol

    2017-04-15

    Environmental pollutants have raised more concerns for human health risk, especially via consumption of contaminated food. Terrestrial as well as aquatic animals are capable of bioaccumulation a variety of toxic substances including metallic elements. With increasing anthropogenic activities along the coastal areas, living organisms have more chances to be exposed to released contaminants. In this study, seven metallic elements (Cd, Cu, Fe, Mn, Ni, Pb and Zn) were determined in sediments and water from Don Hoi Lot sandbar, Samutsongkharm province, Thailand. Potential human health risks via the consumption of two benthic bivalves Solen corneus (Larmarck, 1818) and Meretrix meretrix (Linnaeus, 1758) were also estimated using the target hazard quotients (THQs). The variations of metallic element concentrations were apparent between wet and dry season. Fe was the predominate metallic element in the sediment and the remaining were Mn>Pb>Zn>Ni>Cu>Cd. Whereas metallic element concentrations in water were Pb>Ni>Fe>Zn>Cu>Mn>Cd. PCA analysis confirmed that the contaminations of these metallic elements were from Mae Klong river surface water. Most Pb THQ values in both S. corneus and M. meretrix were >1 indicating that human health risk is of concern. However, the sum of THQs of an individual metallic element should also be considered since multiple metallic elements exposure is so common. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. An analysis of human exposure to trace elements from deliberate soil ingestion and associated health risks.

    PubMed

    Ngole-Jeme, Veronica M; Ekosse, Georges-Ive E; Songca, Sandile P

    2018-01-01

    Fifty-seven samples of soils commonly ingested in South Africa, Swaziland, Democratic Republic of Congo (DRC), and Togo were analyzed for the concentrations of arsenic (As), cadmium (Cd), cobalt (Co), chromium (Cr), copper (Cu), lead (Pb), manganese (Mn), nickel (Ni), and zinc (Zn) and their bioaccessibility in the human gastrointestinal tract. Bioaccessibility values were used to calculate daily intake, and hazard quotient of each trace element, and chronic hazard index (CHI) of each sample. Carcinogenic risk associated with As and Ni exposure were also calculated. Mean pseudo-total concentrations of trace elements in all samples were 7.2, 83.3, 77.1, 15.4, 28.6, 24.9, 56.1, 2.8, and 26.5 mg/kg for As, Cr, Mn, Co, Ni, Cu, Zn, Cd, and Pb, respectively. Percent bioaccessibility of Pb (13-49%) and Zn (38-56%) were highest among trace elements studied. Average daily intake values were lower than their respective reference doses for ell elements except for Pb in selected samples. Samples from DRC presented the highest health risks associated with trace element exposure with most of the samples having CHI values between 0.5 and 1.0. Some samples had higher than unacceptable values of carcinogenic risk associated with As and Ni exposure. Results indicate low trace element exposure risk from ingesting most of the soil samples.

  2. Finite element probabilistic risk assessment of transmission line insulation flashovers caused by lightning strokes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bacvarov, D.C.

    1981-01-01

    A new method for probabilistic risk assessment of transmission line insulation flashovers caused by lightning strokes is presented. The utilized approach of applying the finite element method for probabilistic risk assessment is demonstrated to be very powerful. The reasons for this are two. First, the finite element method is inherently suitable for analysis of three dimensional spaces where the parameters, such as three variate probability densities of the lightning currents, are non-uniformly distributed. Second, the finite element method permits non-uniform discretization of the three dimensional probability spaces thus yielding high accuracy in critical regions, such as the area of themore » low probability events, while at the same time maintaining coarse discretization in the non-critical areas to keep the number of grid points and the size of the problem to a manageable low level. The finite element probabilistic risk assessment method presented here is based on a new multidimensional search algorithm. It utilizes an efficient iterative technique for finite element interpolation of the transmission line insulation flashover criteria computed with an electro-magnetic transients program. Compared to other available methods the new finite element probabilistic risk assessment method is significantly more accurate and approximately two orders of magnitude computationally more efficient. The method is especially suited for accurate assessment of rare, very low probability events.« less

  3. Heap leach cyanide irrigation and risk to wildlife: Ramifications for the international cyanide management code.

    PubMed

    Donato, D B; Madden-Hallett, D M; Smith, G B; Gursansky, W

    2017-06-01

    Exposed cyanide-bearing solutions associated with gold and silver recovery processes in the mining industry pose a risk to wildlife that interact with these solutions. This has been documented with cyanide-bearing tailings storage facilities, however risks associated with heap leach facilities are poorly documented, monitored and audited. Gold and silver leaching heap leach facilities use cyanide, pH-stabilised, at concentrations deemed toxic to wildlife. Their design and management are known to result in exposed cyanide-bearing solutions that are accessible to and present a risk to wildlife. Monitoring of the presence of exposed solutions, wildlife interaction, interpretation of risks and associated wildlife deaths are poorly documented. This paper provides a list of critical monitoring criteria and attempts to predict wildlife guilds most at risk. Understanding the significance of risks to wildlife from exposed cyanide solutions is complex, involving seasonality, relative position of ponding, temporal nature of ponding, solution palatability, environmental conditions, in situ wildlife species inventory and provision of alternative drinking sources for wildlife. Although a number of heap leach operations are certified as complaint with the International Cyanide Management Code (Cyanide Code), these criteria are not considered by auditors nor has systematic monitoring regime data been published. Without systematic monitoring and further knowledge, wildlife deaths on heap leach facilities are likely to remain largely unrecorded. This has ramifications for those operations certified as compliance with the Cyanide Code. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Understanding the impact of supervision on reducing medication risks: an interview study in long-term elderly care.

    PubMed

    Vermeulen, J A; Kleefstra, S M; Zijp, E M; Kool, R B

    2017-07-06

    In 2009, the Dutch Health Care Inspectorate (IGZ) observed several serious risks to safety involving medication within elderly care facilities. However, by 2011, high risks had been reduced in almost all the organisations we visited. And yet the IGZ analysed too the alarming increase in the number of incidents arising in the self-reported national indicator of medication safety between 2009 and 2010. The aim of this study was to understand the factors that can explain this contradiction between the increase in self-reported medication incidents and the observation of the IGZ in reducing the risks to medication safety through supervision. We interviewed health care professionals of ten care facilities, visited by the IGZ, who were involved in, or responsible for, the improvement of medication safety in their institutions. As outcome measures we used the rate of medication safety risk per facility; the perceptions of the participant with regard to the reports of medication incidents; the level of medication safety of the facility; the measures used to improve medication safety; and the supervision of medication safety. This was a mixed methods study, qualitative in that we used semi-structured interviews, and quantitative, by calculating risks for the different organisations we visited. The findings from both study methods resulted in a comprehensive view and an in-depth understanding of this contradiction. The contradiction between the increase in self-reported medication incidents and the observation of reduced risks was explained by three themes: activities designed to improve medication safety, the reporting of medication incidents, and, lastly, the impact of supervision. The focus of the IGZ on issues of medication safety stimulated most elderly care facilities to reduce medication risks. Also, a change in the culture of reporting incidents caused an increase in the number of reported incidents. Supervision contributed to an improvement in actions geared towards reducing the risks associated with the safety of medication. It also increased a willingness to report such incidents. The more incidents reported are therefore not necessarily a sign of an increase in the risks, but can also be considered as a sign of a safer culture.

  5. Extraterrestrial processing and manufacturing of large space systems, volume 2, chapters 7-14 and appendices

    NASA Technical Reports Server (NTRS)

    Miller, R. H.; Smith, D. B. S.

    1979-01-01

    Production and support equipment specifications are described for the space manufacturing facility (SMF). Defined production equipment includes electromagnetic pumps for liquid metal, metal alloying furnaces, die casters, electron beam welders and cutters, glass forming for structural elements, and rolling. A cost analysis is presented which includes the development, the aquisition of all SMF elements, initial operating cost, maintenance and logistics cost, cost of terrestrial materials, and transportation cost for each major element. Computer program listings and outputs are appended.

  6. Trace Elements Contamination and Human Health Risk Assessment in Drinking Water from the Agricultural and Pastoral Areas of Bay County, Xinjiang, China.

    PubMed

    Turdi, Muyessar; Yang, Linsheng

    2016-09-23

    Tap water samples were collected from 180 families in four agricultural (KYR: Keyir, KRW: Kariwak, YTR: Yatur, DW: Dawanqi) and two pastoral areas (B: Bulong and Y: Yangchang) in Bay County, Xinjiang, China, and levels of seven trace elements (Cd, Cr, As Ni, Pb, Zn, Se) were analyzed using inductively-coupled plasma mass spectrometry (ICP-MS) to assess potential health risks. Remarkable spatial variations of contamination were observed. Overall, the health risk was more severe for carcinogenic versus non-carcinogenic pollutants due to heavy metal. The risk index was greater for children overall (Cr > As > Cd and Zn > Se for carcinogenic and non-carcinogenic elements, respectively). The total risk index was greater in agricultural areas (DW > KYR > YTR > KRW > B > Y). Total risk indices were greater where well water was the source versus fountain water; for the latter, the total health risk index was greater versus glacier water. Main health risk factors were Cr and As in DW, KYR, YTR, KRW, and B, and Zn, Cr, and As in the Y region. Overall, total trace element-induced health risk (including for DW adults) was higher than acceptable (10(-6)) and lower than priority risk levels (10(-4)) (KYR, YTR, KRW, Y, and B). For DW children, total health risk reached 1.08 × 10(-4), higher than acceptable and priority risk levels (10(-4)).

  7. Nuclotron-Based Ion Collider Facility (nica)

    NASA Astrophysics Data System (ADS)

    Meshkov, I.; Sissakian, A.; Sorin, A.

    2008-09-01

    The project of an ion collider accelerator complex NICA that is under development at JINR is presented. The article is based on the Conceptual Design Report (CDR)1 of the NICA project delivered in January 2008. The article contains NICA facility scheme, the facility operation scenario, its elements parameters, the proposed methods of intense ion beam acceleration and achievement of the required luminosity of the collider. The symmetric mode of the collider operation is considered here and most attention is concentrated on the luminosity provision in collisions of uranium ions (nuclei).

  8. The target vacuum storage facility at iThemba LABS

    NASA Astrophysics Data System (ADS)

    Neveling, R.; Kheswa, N. Y.; Papka, P.

    2018-05-01

    A number of nuclear physics experiments at iThemba LABS require target foils that consist of specific isotopes of elements which are reactive in air. Not only is it important to prepare these targets in a suitable environment to prevent oxidation, but consideration should also be given to the long term storage and handling facilities of such targets. The target vacuum storage facility at iThemba LABS, as well as additional hardware necessary to transport and install the target foils in the experimental chamber, will be discussed.

  9. Facility-level association of preoperative stress testing and postoperative adverse cardiac events.

    PubMed

    Valle, Javier A; Graham, Laura; Thiruvoipati, Thejasvi; Grunwald, Gary; Armstrong, Ehrin J; Maddox, Thomas M; Hawn, Mary T; Bradley, Steven M

    2018-06-22

    Despite limited indications, preoperative stress testing is often used prior to non-cardiac surgery. Patient-level analyses of stress testing and outcomes are limited by case mix and selection bias. Therefore, we sought to describe facility-level rates of preoperative stress testing for non-cardiac surgery, and to determine the association between facility-level preoperative stress testing and postoperative major adverse cardiac events (MACE). We identified patients undergoing non-cardiac surgery within 2 years of percutaneous coronary intervention in the Veterans Affairs (VA) Health Care System, from 2004 to 2011, facility-level rates of preoperative stress testing and postoperative MACE (death, myocardial infarction (MI) or revascularisation within 30 days). We determined risk-standardised facility-level rates of stress testing and postoperative MACE, and the relationship between facility-level preoperative stress testing and postoperative MACE. Among 29 937 patients undergoing non-cardiac surgery at 131 VA facilities, the median facility rate of preoperative stress testing was 13.2% (IQR 9.7%-15.9%; range 6.0%-21.5%), and 30-day postoperative MACE was 4.0% (IQR 2.4%-5.4%). After risk standardisation, the median facility-level rate of stress testing was 12.7% (IQR 8.4%-17.4%) and postoperative MACE was 3.8% (IQR 2.3%-5.6%). There was no correlation between risk-standardised stress testing and composite MACE at the facility level (r=0.022, p=0.81), or with individual outcomes of death, MI or revascularisation. In a national cohort of veterans undergoing non-cardiac surgery, we observed substantial variation in facility-level rates of preoperative stress testing. Facilities with higher rates of preoperative stress testing were not associated with better postoperative outcomes. These findings suggest an opportunity to reduce variation in preoperative stress testing without sacrificing patient outcomes. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  10. Quantitative comparison between PGNAA measurements and MCNP calculations in view of the characterization of radioactive wastes in Germany and France

    NASA Astrophysics Data System (ADS)

    Mauerhofer, E.; Havenith, A.; Carasco, C.; Payan, E.; Kettler, J.; Ma, J. L.; Perot, B.

    2013-04-01

    The Forschungszentrum Jülich GmbH (FZJ), together with the Aachen University Rheinisch-Westfaelische Technische Hochschule (RWTH) and the French Alternative Energies and Atomic Energy Commission (CEA Cadarache) are involved in a cooperation aiming at characterizing toxic and reactive elements in radioactive waste packages by means of Prompt Gamma Neutron Activation Analysis (PGNAA) [1]. The French and German waste management agencies have indeed defined acceptability limits concerning these elements in view of their projected geological repositories. A first measurement campaign was performed in the new Prompt Gamma Neutron Activation Analysis (PGNAA) facility called MEDINA, at FZJ, to assess the capture gamma-ray signatures of some elements of interest in large samples up to waste drums with a volume of 200 liter. MEDINA is the acronym for Multi Element Detection based on Instrumental Neutron Activation. This paper presents MCNP calculations of the MEDINA facility and quantitative comparison between measurement and simulation. Passive gamma-ray spectra acquired with a high purity germanium detector and calibration sources are used to qualify the numerical model of the crystal. Active PGNAA spectra of a sodium chloride sample measured with MEDINA then allow for qualifying the global numerical model of the measurement cell. Chlorine indeed constitutes a usual reference with reliable capture gamma-ray production data. The goal is to characterize the entire simulation protocol (geometrical model, nuclear data, and postprocessing tools) which will be used for current measurement interpretation, extrapolation of the performances to other types of waste packages or other applications, as well as for the study of future PGNAA facilities.

  11. Fifth anniversary of the first element of the International Spac

    NASA Image and Video Library

    2003-12-03

    Members of the media (at right) were invited to commemorate the fifth anniversary of the launch of the International Space Station by touring the Space Station Processing Facility (SSPF) at KSC. Giving an overview of Space Station processing are, at left, David Bethay (white shirt), Boeing/ISS Florida Operations; Charlie Precourt, deputy manager of the International Space Station Program; and Tip Talone, director of Space Station and Payload Processing at KSC. Reporters also had the opportunity to see Space Station hardware that is being processed for deployment once the Space Shuttles return to flight. The facility tour also included an opportunity for reporters to talk with NASA and Boeing mission managers about the various hardware elements currently being processed for flight.

  12. Risk prioritisation using the analytic hierarchy process

    NASA Astrophysics Data System (ADS)

    Sum, Rabihah Md.

    2015-12-01

    This study demonstrated how to use the Analytic Hierarchy Process (AHP) to prioritise risks of an insurance company. AHP is a technique to structure complex problems by arranging elements of the problems in a hierarchy, assigning numerical values to subjective judgements on the relative importance of the elements and synthesizing the judgements to determine which elements have the highest priority. The study is motivated by wide application of AHP as a prioritisation technique in complex problems. It aims to show AHP is able to minimise some limitations of risk assessment technique using likelihood and impact. The study shows AHP is able to provide consistency check on subjective judgements, organise a large number of risks into a structured framework, assist risk managers to make explicit risk trade-offs, and provide an easy to understand and systematic risk assessment process.

  13. Risk assessment as standard work in design.

    PubMed

    Morrill, Patricia W

    2013-01-01

    This case study article examines a formal risk assessment as part of the decision making process for design solutions in high risk areas. The overview of the Failure Modes and Effects Analysis (FMEA) tool with examples of its application in hospital building projects will demonstrate the benefit of those structured conversations. This article illustrates how two hospitals used FMEA when integrating operational processes with building projects: (1) adjacency decision for Intensive Care Unit (ICU); and (2) distance concern for handling of specimens from Surgery to Lab. Both case studies involved interviews that exposed facility solution concerns. Just-in-time studies using the FMEA followed the same risk assessment process with the same workshop facilitator involving structured conversations in analyzing risks. In both cases, participants uncovered key areas of risk enabling them to take the necessary next steps. While the focus of this article is not the actual design solution, it is apparent that the risk assessment brought clarity to the situations resulting in prompt decision making about facility solutions. Hospitals are inherently risky environments; therefore, use of the formal risk assessment process, FMEA, is an opportunity for design professionals to apply more rigor to design decision making when facility solutions impact operations in high risk areas. Case study, decision making, hospital, infection control, strategy, work environment.

  14. 6 CFR 27.215 - Security vulnerability assessments.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 6 Domestic Security 1 2010-01-01 2010-01-01 false Security vulnerability assessments. 27.215... FACILITY ANTI-TERRORISM STANDARDS Chemical Facility Security Program § 27.215 Security vulnerability...-risk, the facility must complete a Security Vulnerability Assessment. A Security Vulnerability...

  15. RELEASE OF DRIED RADIOACTIVE WASTE MATERIALS TECHNICAL BASIS DOCUMENT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    KOZLOWSKI, S.D.

    2007-05-30

    This technical basis document was developed to support RPP-23429, Preliminary Documented Safety Analysis for the Demonstration Bulk Vitrification System (PDSA) and RPP-23479, Preliminary Documented Safety Analysis for the Contact-Handled Transuranic Mixed (CH-TRUM) Waste Facility. The main document describes the risk binning process and the technical basis for assigning risk bins to the representative accidents involving the release of dried radioactive waste materials from the Demonstration Bulk Vitrification System (DBVS) and to the associated represented hazardous conditions. Appendices D through F provide the technical basis for assigning risk bins to the representative dried waste release accident and associated represented hazardous conditionsmore » for the Contact-Handled Transuranic Mixed (CH-TRUM) Waste Packaging Unit (WPU). The risk binning process uses an evaluation of the frequency and consequence of a given representative accident or represented hazardous condition to determine the need for safety structures, systems, and components (SSC) and technical safety requirement (TSR)-level controls. A representative accident or a represented hazardous condition is assigned to a risk bin based on the potential radiological and toxicological consequences to the public and the collocated worker. Note that the risk binning process is not applied to facility workers because credible hazardous conditions with the potential for significant facility worker consequences are considered for safety-significant SSCs and/or TSR-level controls regardless of their estimated frequency. The controls for protection of the facility workers are described in RPP-23429 and RPP-23479. Determination of the need for safety-class SSCs was performed in accordance with DOE-STD-3009-94, Preparation Guide for US. Department of Energy Nonreactor Nuclear Facility Documented Safety Analyses, as described below.« less

  16. Reducing the Risk of Dangerous Chemicals Getting into the Wrong Hands

    ERIC Educational Resources Information Center

    Matthews, Nancy

    2008-01-01

    Under the Department of Homeland Security (DHS) Appropriations Act of 2007, DHS has the authority and funding to regulate security at facilities storing chemicals considered to be high-risk (P. L. 109-295, Section 550). This article discusses the Department's efforts to enhance the security of facilities that store chemicals that could be stolen…

  17. Data development technical support document for the aircraft crash risk analysis methodology (ACRAM) standard

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kimura, C.Y.; Glaser, R.E.; Mensing, R.W.

    1996-08-01

    The Aircraft Crash Risk Analysis Methodology (ACRAM) Panel has been formed by the US Department of Energy Office of Defense Programs (DOE/DP) for the purpose of developing a standard methodology for determining the risk from aircraft crashes onto DOE ground facilities. In order to accomplish this goal, the ACRAM panel has been divided into four teams, the data development team, the model evaluation team, the structural analysis team, and the consequence team. Each team, consisting of at least one member of the ACRAM plus additional DOE and DOE contractor personnel, specializes in the development of the methodology assigned to thatmore » team. This report documents the work performed by the data development team and provides the technical basis for the data used by the ACRAM Standard for determining the aircraft crash frequency. This report should be used to provide the generic data needed to calculate the aircraft crash frequency into the facility under consideration as part of the process for determining the aircraft crash risk to ground facilities as given by the DOE Standard Aircraft Crash Risk Assessment Methodology (ACRAM). Some broad guidance is presented on how to obtain the needed site-specific and facility specific data but this data is not provided by this document.« less

  18. A Collaborative Study of Disproportionate Chemical Risks in Seven Delaware Communities

    NASA Astrophysics Data System (ADS)

    Dryden, O.; Goldman, G. T.; White, R.; Moore, D.; Roberts, M.; Thomas, J.; Johnson, C.

    2017-12-01

    Studies have found that, compared to national averages, a significantly greater percentage of Blacks (African-Americans), Latinos (Hispanics), and people at or near poverty levels tend to live near industrial facilities that use large quantities of toxic chemicals and present a risk of major chemical disasters with potentially severe consequences for nearby communities. The Union of Concerned Scientists, the Environmental Justice Health Alliance for Chemical Policy Reform, and Delaware Concerned Residents for Environmental Justice collaborated on a study to examine the potential for cumulative impacts from health and safety risks for seven Delaware communities with a percentage of people of color and/or poverty levels greater than the Delaware average located along an industrial corridor in the northern portion of Delaware's New Castle County. These risks include close proximity to major industrial sources, as well as facilities that use large quantities of toxic, flammable or explosive chemicals and pose a high risk of a major chemical release or catastrophic incident. Additionally, proximity to contaminated waste sites was assessed, as well as the risk of cancer and potential for respiratory disease impacts from exposure to toxic air pollution. We found that people in these seven communities face a substantial cumulative health risk from exposure to toxic air pollution, proximity to polluting industrial facilities and hazardous chemical facilities, as well as contaminated waste sites. These health risks are substantially greater when compared to a wealthier and predominantly White Delaware community and for Delaware as a whole. Significant and expedited improvements in regulatory and public policy are needed at the national, state, and municipal levels to address the health and well-being of at-risk communities in Delaware and elsewhere.

  19. Development of an external beam nuclear microprobe on the Aglae facility of the Louvre museum

    NASA Astrophysics Data System (ADS)

    Calligaro, T.; Dran, J.-C.; Ioannidou, E.; Moignard, B.; Pichon, L.; Salomon, J.

    2000-03-01

    The external beam line of our facility has been recently equipped with the focusing system previously mounted on a classical nuclear microprobe. When using a 0.1 μm thick Si 3N 4 foil for the exit window and flowing helium on the sample under analysis, a beam spot as small as 10 μm is attainable at a distance of 3 mm from the window. Elemental micromapping is performed by mechanical scanning. An electronic device has been designed which allows XY scanning by moving the sample under the beam by steps down to 0.1 μm. Beam monitoring is carried out by means of the weak X-ray signal emitted by the exit foil and detected by a specially designed Si(Li) detector cooled by Peltier effect. The characteristics of external beams of protons and alpha particles are evaluated by means of resonance scanning and elemental mapping of a grid. An example of application is presented, dealing with elemental micro-mapping of inclusions in gemstones.

  20. PIXE analysis of historical paintings: Is the gain worth the risk?

    NASA Astrophysics Data System (ADS)

    Calligaro, T.; Gonzalez, V.; Pichon, L.

    2015-11-01

    The PIXE analysis of easel paintings constitutes a challenging task. Despite recognized merits and a few emblematic applications, PIXE has never been routinely applied to these fragile, complex and precious targets. The present work discusses the place of PIXE in the study of easel paintings and opens up perspectives for a more systematic usage of this analytical technique. Progress achieved since decades in the implementation of PIXE to study such fragile cultural heritage artefacts is reviewed, notably at the LABEC laboratory in Italy and at the AGLAE facility of the C2RMF in France. Two specific techniques developed for paintings are detailed and exemplified on Renaissance painting masterpieces: differential PIXE for paint layers depth profiling and multi-scale elemental mapping for the imaging of pigment distribution. Beam-induced damage, a major concern, notably depends on the employed beam fluence in particle/cm2 or μC/cm2. After recalling previous works on damage induced in chemical products comparable to pigments, we present the behaviour under different fluences of protons of a few MeV (1-300 μC/cm2) of targets having high resemblance to historical easel paintings: pellets of specially synthesized lead white pigments, layers of lead white mixed with linseed oil and areas containing lead white of two 19th century paintworks. The results shed new lights on the behaviour of paintworks under the beam and pave the way to strategies for damage mitigation. In particular, the lowering of PIXE performance induced by the decrease of the beam fluence sets a trade-off between risk of damage and gained information which also impacts the PIXE scanning protocol for paintings. As an illustration of an adequate adjustment of this balance, we report the exploratory application of PIXE mapping to a large area of a 19th century easel painting without damage. The recorded elemental maps are compared to elemental maps collected on the same area using laboratory-based scanning XRF.

  1. Fire safety knowledge and practices among residents of an assisted living facility.

    PubMed

    Jaslow, David; Ufberg, Jacob; Yoon, Russell; McQueen, Clay; Zecher, Derek; Jakubowski, Greg

    2005-01-01

    Assisted living facilities (ALFs) pose unique fire risks to the elderly that may be linked to specific fire safety (FS) practices. To evaluate self-reported FS practices among ALF residents. All residents of a small ALF were surveyed regarding actual and hypothetical FS behaviors, self-perceived fire risk, and FS preparedness. Fifty-eight ALF residents completed the survey. Thirty-three (58%) individuals reported one or more disabilities. Seven (12%) residents ignored the fire alarm and 21 (35%) could not hear it clearly. Sixteen (28%) residents would attempt to locate the source of a fire rather than escape from the building. Only 24 (42%) residents were familiar with the building fire plan. Twenty-three (40%) people surveyed believed that they were not at risk of fire in the study facility. Residents of an ALF may be at increased fire injury risk due to their FS practices and disabilities.

  2. Terrorism-related risk management for health care facilities.

    PubMed

    Reid, Daniel J; Reid, William H

    2005-01-01

    Clinicians should have a basic understanding of the physical and financial risk to mental health facilities related to external threat, such as (but not necessarily limited to) terrorism. Patient care and accessibility to mental health services rest not only on clinical skills, but on a place to practice them and an organized system supported by staff, physical facilities and funding. Clinicians who have some familiarity with the non-clinical requirements for care are in a position to support non-clinical staff in preventing care from being interrupted by external threats or events such as terrorist activity, and/or serving at the interface of facility operations and direct clinical care. Readers should note that this article is an introduction to the topic and cannot address all local, state, and national standards for hospital safety, or insurance providers' individual facility requirements.

  3. Senator Doug Jones (D-AL) Tour of MSFC Facilities

    NASA Image and Video Library

    2018-02-22

    Senator Doug Jones (D-AL.) and wife, Louise, tour Marshall Space Flight facilities. Steve Doering, manager, Stages Element, Space Launch System (SLS) program at MSFC, also tour the Payload Operations Integration Center (POIC) where Marshall controllers oversee stowage requirements aboard the International Space Station (ISS) as well as scientific experiments. Different positions in the room are explained to Senator Jones by MSFC controller Beau Simpson.

  4. Australian DefenceScience. Volume 15, Number 4, Summer

    DTIC Science & Technology

    2007-01-01

    components, the magnesium alloy gear box case and numerous connectors in the avionics systems, that are susceptible. “When considering ways to alleviate...with associated structural properties . The elements are linked to each other by mathematical equations that determine the response to ANZACS...intellectual property , secondment of industry staff to the JDSSC and ways of making network connections with industry facilities. The facility is

  5. FRS Download Summary and Data Element Dictionary ...

    EPA Pesticide Factsheets

    ECHO, Enforcement and Compliance History Online, provides compliance and enforcement information for approximately 800,000 EPA-regulated facilities nationwide. ECHO includes permit, inspection, violation, enforcement action, and penalty information about facilities regulated under the Clean Air Act (CAA) Stationary Source Program, Clean Water Act (CWA) National Pollutant Elimination Discharge System (NPDES), and/or Resource Conservation and Recovery Act (RCRA). Information also is provided on surrounding demographics when available.

  6. ICIS-NPDES Download Summary and Data Element ...

    EPA Pesticide Factsheets

    ECHO, Enforcement and Compliance History Online, provides compliance and enforcement information for approximately 800,000 EPA-regulated facilities nationwide. ECHO includes permit, inspection, violation, enforcement action, and penalty information about facilities regulated under the Clean Air Act (CAA) Stationary Source Program, Clean Water Act (CWA) National Pollutant Elimination Discharge System (NPDES), and/or Resource Conservation and Recovery Act (RCRA). Information also is provided on surrounding demographics when available.

  7. RCRAInfo Download Summary and Data Element Dictionary ...

    EPA Pesticide Factsheets

    ECHO, Enforcement and Compliance History Online, provides compliance and enforcement information for approximately 800,000 EPA-regulated facilities nationwide. ECHO includes permit, inspection, violation, enforcement action, and penalty information about facilities regulated under the Clean Air Act (CAA) Stationary Source Program, Clean Water Act (CWA) National Pollutant Elimination Discharge System (NPDES), and/or Resource Conservation and Recovery Act (RCRA). Information also is provided on surrounding demographics when available.

  8. 40 CFR Appendix A to Subpart A of... - Tables

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... precursor of PM2.5. Table 2a to Appendix A of Subpart A—Data Elements for Reporting on Emissions From Point Sources, Where Required by 40 CFR 51.30 Data elements Every-yearreporting Three-yearreporting (1... phone number ✓ ✓ (6) FIPS code ✓ ✓ (7) Facility ID codes ✓ ✓ (8) Unit ID code ✓ ✓ (9) Process ID code...

  9. 33 CFR Appendix D to Part 154 - Training Elements for Oil Spill Response Plans

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Response Plans D Appendix D to Part 154 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) POLLUTION FACILITIES TRANSFERRING OIL OR HAZARDOUS MATERIAL IN BULK Pt. 154, App. D Appendix D to Part 154—Training Elements for Oil Spill Response Plans 1. General 1.1The portion of the plan...

  10. DEVELOPMENT AND DEMONSTRATION OF A PILOT SCALE FACILITY FOR FABRICATION AND MARKETING OF LIGHTWEIGHT-COAL COMBUSTION BYPRODUCTS-BASED SUPPORTS AND MINE VENTILATION BLOCKS FOR UNDERGROUND MINES

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yoginder P. Chugh

    2002-10-01

    The overall goal of this program was to develop a pilot scale facility, and design, fabricate, and market CCBs-based lightweight blocks for mine ventilation control devices, and engineered crib elements and posts for use as artificial supports in underground mines to replace similar wooden elements. This specific project was undertaken to (1) design a pilot scale facility to develop and demonstrate commercial production techniques, and (2) provide technical and marketing support to Fly Lite, Inc to operate the pilot scale facility. Fly Lite, Inc is a joint venture company of the three industrial cooperators who were involved in research intomore » the development of CCBs-based structural materials. The Fly-Lite pilot scale facility is located in McLeansboro, Illinois. Lightweight blocks for use in ventilation stoppings in underground mines have been successfully produced and marketed by the pilot-scale facility. To date, over 16,000 lightweight blocks (30-40 pcf) have been sold to the mining industry. Additionally, a smaller width (6-inch) full-density block was developed in August-September 2002 at the request of a mining company. An application has been submitted to Mine Safety and Health Administration for the developed block approval for use in mines. Commercialization of cribs and posts has also been accomplished. Two generations of cribs have been developed and demonstrated in the field. MSHA designated them suitable for use in mines. To date, over 2,000 crib elements have been sold to mines in Illinois. Two generations of posts were also demonstrated in the field and designated as suitable for use in mines by MSHA. Negotiations are currently underway with a mine in Illinois to market about 1,000 posts per year based on a field demonstration in their mine. It is estimated that 4-5 million tons CCBs (F-fly ash or FBC fly ash) may be utilized if the developed products can be commercially implemented in U.S. coal and non-coal mines.« less

  11. Incorporating elements of social franchising in government health services improves the quality of infant and young child feeding counselling services at commune health centres in Vietnam.

    PubMed

    Nguyen, Phuong H; Kim, Sunny S; Keithly, Sarah C; Hajeebhoy, Nemat; Tran, Lan M; Ruel, Marie T; Rawat, Rahul; Menon, Purnima

    2014-12-01

    Although social franchising has been shown to enhance the quality of reproductive health services in developing countries, its effect on nutrition services remains unexamined. This study assessed the effects of incorporating elements of social franchising on shaping the quality of infant and young child feeding (IYCF) counselling facilities and services in Vietnam. Process-related data collected 12 months after the launch of the first franchises were used to compare randomly assigned Alive & Thrive-supported health facilities (AT-F, n = 20) with standard facilities (SF, n = 12) across three dimensions of service quality: 'structure', 'process' and 'outcome' that capture the quality of facilities, service delivery, and client perceptions and use, respectively. Data collection included facility assessments (n = 32), staff surveys (n = 96), counselling observations (n = 137), client exit interviews (n = 137) and in-depth interviews with mothers (n = 48). Structure: AT-F were more likely to have an unshared, well-equipped room for nutrition counselling than SF (65.0% vs 10.0%). Compared with SF providers, AT-F staff had better IYCF knowledge (mean score 9.9 vs 8.8, range 0-11 for breastfeeding; mean score 3.6 vs 3.2, range 0-4 for complementary feeding). AT-F providers also demonstrated significantly better interpersonal communication skills (score 9.6 vs 5.1, range 0-13) and offered more comprehensive counselling sessions. Overall utilization of franchises was low (10%). A higher proportion of pregnant women utilized franchise services (48.9%), compared with mothers with children 6-23.9 months (1.4%). There was no quantitative difference in client satisfaction with counselling services between AT-F and SF, but franchise users praised the AT-F for problem solving related to child feeding. Incorporating elements of social franchising significantly enhances the quality of IYCF counselling services within government primary healthcare facilities, particularly their structural and process attributes. Provided that service utilization is improved through demand generation, this model has the potential to impact IYCF practices and child nutrition. Published by Oxford University Press in association with The London School of Hygiene and Tropical Medicine © The Author 2013; all rights reserved.

  12. 32 CFR 766.5 - Conditions governing use of aviation facilities by civil aircraft.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 32 National Defense 5 2012-07-01 2012-07-01 false Conditions governing use of aviation facilities... OF THE NAVY MISCELLANEOUS RULES USE OF DEPARTMENT OF THE NAVY AVIATION FACILITIES BY CIVIL AIRCRAFT § 766.5 Conditions governing use of aviation facilities by civil aircraft. (a) Risk. The use of Navy or...

  13. 32 CFR 766.5 - Conditions governing use of aviation facilities by civil aircraft.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 32 National Defense 5 2014-07-01 2014-07-01 false Conditions governing use of aviation facilities... OF THE NAVY MISCELLANEOUS RULES USE OF DEPARTMENT OF THE NAVY AVIATION FACILITIES BY CIVIL AIRCRAFT § 766.5 Conditions governing use of aviation facilities by civil aircraft. (a) Risk. The use of Navy or...

  14. 32 CFR 766.5 - Conditions governing use of aviation facilities by civil aircraft.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 32 National Defense 5 2013-07-01 2013-07-01 false Conditions governing use of aviation facilities... OF THE NAVY MISCELLANEOUS RULES USE OF DEPARTMENT OF THE NAVY AVIATION FACILITIES BY CIVIL AIRCRAFT § 766.5 Conditions governing use of aviation facilities by civil aircraft. (a) Risk. The use of Navy or...

  15. Risk-based Prioritization of Facility Decommissioning and Environmental Restoration Projects in the National Nuclear Legacy Liabilities Program at the Chalk River Laboratory - 13564

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nelson, Jerel G.; Kruzic, Michael; Castillo, Carlos

    2013-07-01

    Chalk River Laboratory (CRL), located in Ontario Canada, has a large number of remediation projects currently in the Nuclear Legacy Liabilities Program (NLLP), including hundreds of facility decommissioning projects and over one hundred environmental remediation projects, all to be executed over the next 70 years. Atomic Energy of Canada Limited (AECL) utilized WorleyParsons to prioritize the NLLP projects at the CRL through a risk-based prioritization and ranking process, using the WorleyParsons Sequencing Unit Prioritization and Estimating Risk Model (SUPERmodel). The prioritization project made use of the SUPERmodel which has been previously used for other large-scale site prioritization and sequencing ofmore » facilities at nuclear laboratories in the United States. The process included development and vetting of risk parameter matrices as well as confirmation/validation of project risks. Detailed sensitivity studies were also conducted to understand the impacts that risk parameter weighting and scoring had on prioritization. The repeatable prioritization process yielded an objective, risk-based and technically defendable process for prioritization that gained concurrence from all stakeholders, including Natural Resources Canada (NRCan) who is responsible for the oversight of the NLLP. (authors)« less

  16. Use of geographic information systems technology to track critical health code violations in retail facilities available to populations of different socioeconomic status and demographics.

    PubMed

    Darcey, Valerie L; Quinlan, Jennifer J

    2011-09-01

    Research shows that community socioeconomic status (SES) predicts, based on food service types available, whether a population has access to healthy food. It is not known, however, if a relationship exists between SES and risk for foodborne illness (FBI) at the community level. Geographic information systems (GIS) give researchers the ability to pinpoint health indicators to specific geographic locations and detect resulting environmental gradients. It has been used extensively to characterize the food environment, with respect to access to healthy foods. This research investigated the utility of GIS in determining whether community SES and/or demographics relate to access to safe food, as measured by food service critical health code violations (CHV) as a proxy for risk for FBI. Health inspection records documenting CHV for 10,859 food service facilities collected between 2005 and 2008 in Philadelphia, PA, were accessed. Using an overlay analysis through GIS, CHV were plotted over census tracts of the corresponding area. Census tracts (n = 368) were categorized into quintiles, based on poverty level. Overall, food service facilities in higher poverty areas had a greater number of facilities (with at least one CHV) and had more frequent inspections than facilities in lower poverty areas. The facilities in lower poverty areas, however, had a higher average number of CHV per inspection. Analysis of CHV rates in census tracts with high concentrations of minority populations found Hispanic facilities had more CHV than other demographics, and Hispanic and African American facilities had fewer days between inspections. This research demonstrates the potential for utilization of GIS mapping for tracking risks for FBI. Conversely, it sheds light on the subjective nature of health inspections, and indicates that underlying factors might be affecting inspection frequency and identification of CHV, such that CHV might not be a true proxy for risk for FBI.

  17. Does closure of children's medical home impact their immunization coverage?

    PubMed

    Kolasa, M S; Stevenson, J; Ossa, A; Lutz, J

    2014-12-01

    Little is known about the impact closing a health care facility has on immunization coverage of children utilizing that facility as a medical home. The authors assessed the impact of closing a Medicaid managed care facility in Philadelphia on immunization coverage of children, primarily low income children from racial/ethnic minority groups, utilizing that facility for routine immunizations. Observational longitudinal cohort case study. Eligible children were born 03/01/05-06/30/07, present in Philadelphia's immunization information system (IIS), and were active clients of the facility before it closed in September 2007. IIS-recorded immunization coverage at ages 5, 7, 13, 16 and 19 months through January 2009 was compared between clinic children age-eligible to receive specific vaccines before clinic closing (preclosure cohorts) and children not age-eligible to receive those vaccines prior to closing (postclosure cohorts). Of 630 eligible children, 99 (16%) had no additional IIS-recorded immunizations. Third dose DTaP vaccine coverage at age seven months among preclosure cohorts was 54.4% vs. 40.3% among postclosure cohorts [risk ratio 1.31 (1.15,1.49)]. Fourth dose DTaP coverage at 19 months was 65.9% vs. 57.7% [risk ratio 1.24 (1.08,1.42)]. MMR coverage at 16 months was 79.5% vs. 69.9% [risk ratio 1.47 (1.22, 1.76)]. Coverage for the 431331 vaccination series at 19 months was 63.8% vs. 53.8% [risk ratio 1.28 (1.12,1.88)]. Immunization coverage declined at key age milestones for active clients of a Medicaid managed care that closed as compared with preclosure cohorts of clients from the same facility. When a primary health care facility closes, efforts should be made to ensure that children who had received vaccinations at that facility quickly establish a new medical home. Published by Elsevier Ltd.

  18. Facility-Level Variation in Hospitalization, Mortality, and Costs in the 30 Days After Percutaneous Coronary Intervention: Insights on Short-Term Healthcare Value From the Veterans Affairs Clinical Assessment, Reporting, and Tracking System (VA CART) Program.

    PubMed

    Bradley, Steven M; O'Donnell, Colin I; Grunwald, Gary K; Liu, Chuan-Fen; Hebert, Paul L; Maddox, Thomas M; Jesse, Robert L; Fihn, Stephan D; Rumsfeld, John S; Ho, P Michael

    2015-07-14

    Policies to reduce unnecessary hospitalizations after percutaneous coronary intervention (PCI) are intended to improve healthcare value by reducing costs while maintaining patient outcomes. Whether facility-level hospitalization rates after PCI are associated with cost of care is unknown. We studied 32,080 patients who received PCI at any 1 of 62 Veterans Affairs hospitals from 2008 to 2011. We identified facility outliers for 30-day risk-standardized hospitalization, mortality, and cost. Compared with the risk-standardized average, 2 hospitals (3.2%) had a lower-than-expected hospitalization rate, and 2 hospitals (3.2%) had a higher-than-expected hospitalization rate. We observed no statistically significant variation in facility-level risk-standardized mortality. The facility-level unadjusted median per patient 30-day total cost was $23,820 (interquartile range, $19,604-$29,958). Compared with the risk-standardized average, 17 hospitals (27.4%) had lower-than-expected costs, and 14 hospitals (22.6%) had higher-than-expected costs. At the facility level, the index PCI accounted for 83.1% of the total cost (range, 60.3%-92.2%), whereas hospitalization after PCI accounted for only 5.8% (range, 2.0%-12.7%) of the 30-day total cost. Facilities with higher hospitalization rates were not more expensive (Spearman ρ=0.16; 95% confidence interval, -0.09 to 0.39; P=0.21). In this national study, hospitalizations in the 30 day after PCI accounted for only 5.8% of 30-day cost, and facility-level cost was not correlated with hospitalization rates. This challenges the focus on reducing hospitalizations after PCI as an effective means of improving healthcare value. Opportunities remain to improve PCI value by reducing the variation in total cost of PCI without compromising patient outcomes. © 2015 American Heart Association, Inc.

  19. Mitigating risks related to facilities management.

    PubMed

    O'Neill, Daniel P; Scarborough, Sydney

    2013-07-01

    By looking at metrics focusing on the functionality, age, capital investment, transparency, and sustainability (FACTS) of their organizations' facilities, facilities management teams can build potential business cases to justify upgrading the facilities. A FACTS analysis can ensure that capital spent on facilities will produce a higher or more certain ROI than alternatives. A consistent process for managing spending helps to avoid unexpected spikes that cost the enterprise more in the long run.

  20. Mental Health Disorders, Suicide Risk, and Treatment seeking among Formerly Deployed National Guardand Reserve Service Member seen in Non VA Facilities

    DTIC Science & Technology

    2016-10-01

    1 AWARD NUMBER: W81XWH-15-1-0506 TITLE: Mental Health Disorders, Suicide Risk, and Treatment seeking among Formerly Deployed National Guard... Suicide Risk, and Treatment seeking among Formerly Deployed National Guard and Reserve Service Member seen in Non-VA Facilities 5b. GRANT NUMBER W81XWH...and Reserve veterans. The prevalence of current PTSD was 7% (95% CI = 5.7-8.5). Preliminary analyses indicated that PTSD, depression , mental health

  1. NASA's Agency-Wide Strategy for Environmental Regulatory Risk Analysis and Communication

    NASA Technical Reports Server (NTRS)

    Scroggins, Sharon

    2008-01-01

    NASA's Agency-wide.resource for identifying and managing risks associated with changing environmental regulations Goals of the RRAC PC: 1) Proactively. detect, analyze and communicate environmental regulatory risks to NASA Programs and facilities; 2) Communicate with regulators and participate in the mitigation of such risks; and 3) Provide centralized support on emerging regulations to NASA HQ Environmental Management Division. When significant regulatory changes are identified, timely communication is essential. Communication of changing requirements to the regulatory stakeholders - NASA Programs and Facilities. Communication of potential issues to management and, when appropriate, back to the regulating agency.

  2. Animal research facility for Space Station Freedom

    NASA Technical Reports Server (NTRS)

    Bonting, Sjoerd L.

    1992-01-01

    An integrated animal research facility is planned by NASA for Space Station Freedom which will permit long-term, man-tended experiments on the effects of space conditions on vertebrates. The key element in this facility is a standard type animal habitat which supports and maintains the animals under full bioisolation during transport and during the experiment. A holding unit accommodates the habitats with animals to be maintained at zero gravity; and a centrifuge, those to be maintained at artificial gravity for control purposes or for gravity threshold studies. A glovebox permits handling of the animals for experimental purposes and for transfer to a clean habitat. These facilities are described, and the aspects of environmental control, monitoring, and bioisolation are discussed.

  3. Safety climate and workplace violence prevention in state-run residential addiction treatment centers.

    PubMed

    Lipscomb, Jane A; London, M; Chen, Y M; Flannery, K; Watt, M; Geiger-Brown, J; Johnson, J V; McPhaul, K

    2012-01-01

    To examine the association between violence prevention safety climate measures and self reported violence toward staff in state-run residential addiction treatment centers. In mid-2006, 409 staff from an Eastern United States state agency that oversees a system of thirteen residential addiction treatment centers (ATCs) completed a self-administered survey as part of a comprehensive risk assessment. The survey was undertaken to identify and measure facility-level risk factors for violence, including staff perceptions of the quality of existing US Occupational Safety and Health Administration (OSHA) program elements, and ultimately to guide violence prevention programming. Key informant interviews and staff focus groups provided researchers with qualitative data with which to understand safety climate and violence prevention efforts within these work settings. The frequency with which staff reported experiencing violent behavior ranged from 37% for "clients raised their voices in a threatening way to you" to 1% for "clients pushed, hit, kicked, or struck you". Findings from the staff survey included the following significant predictors of violence: "client actively resisting program" (OR=2.34, 95% CI=1.35, 4.05), "working with clients for whom the history of violence is unknown" (OR=1.91, 95% CI=1.18, 3.09) and "management commitment to violence prevention" reported as "never/hardly ever" and "seldom or sometimes" (OR=4.30 and OR=2.31 respectively), while controlling for other covariates. We utilized a combination of qualitative and quantitative research methods to begin to describe the risk and potential for violence prevention in this setting. The prevalence of staff physical violence within the agency's treatment facilities was lower than would be predicted. Possible explanations include the voluntary nature of treatment programs; strong policies and consequences for resident behavior and ongoing quality improvement efforts. Quantitative data identified low management commitment to violence prevention as a significant predictor of staff reported violence.

  4. Proliferation resistance assessments during the design phase of a recycling facility as a means of reducing proliferation risks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lindell, M.A.; Grape, S.; Haekansson, A.

    The sustainability criterion for Gen IV nuclear energy systems inherently presumes the availability of efficient fuel recycling capabilities. One area for research on advanced fuel recycling concerns safeguards aspects of this type of facilities. Since a recycling facility may be considered as sensitive from a non-proliferation perspective, it is important to address these issues early in the design process, according to the principle of Safeguards By Design. Presented in this paper is a mode of procedure, where assessments of the proliferation resistance (PR) of a recycling facility for fast reactor fuel have been performed so as to identify the weakestmore » barriers to proliferation of nuclear material. Two supplementing established methodologies have been applied; TOPS (Technological Opportunities to increase Proliferation resistance of nuclear power Systems) and PR-PP (Proliferation Resistance and Physical Protection evaluation methodology). The chosen fuel recycling facility belongs to a small Gen IV lead-cooled fast reactor system that is under study in Sweden. A schematic design of the recycling facility, where actinides are separated using solvent extraction, has been examined. The PR assessment methodologies make it possible to pinpoint areas in which the facility can be improved in order to reduce the risk of diversion. The initial facility design may then be slightly modified and/or safeguards measures may be introduced to reduce the total identified proliferation risk. After each modification of design and/or safeguards implementation, a new PR assessment of the revised system can then be carried out. This way, each modification can be evaluated and new ways to further enhance the proliferation resistance can be identified. This type of iterative procedure may support Safeguards By Design in the planning of new recycling plants and other nuclear facilities. (authors)« less

  5. Bioavailability and health risk assessment of potentially toxic elements in Thriasio Plain, near Athens, Greece.

    PubMed

    Antoniadis, Vasileios; Golia, Evangelia E; Shaheen, Sabry M; Rinklebe, Jörg

    2017-04-01

    Elevated concentrations of potentially toxic elements (PTEs) are usually found in areas of intense industrial activity. Thriasio Plain is a plain near Athens, Greece, where most of the heavy industry of the country has been situated for decades, but it also is a residential and horticultural area. We aimed at measuring the levels of PTEs in soils and indigenous plant species and assessing the health risk associated with direct soil ingestion. Samples of soils at roadsides and growing plants were collected from 31 sites of that area. Concentrations of Al, As, Cd, Co, Cr, Cu, Fe, Mn, Mo, Ni, Pb, V and Zn were measured in both soils (as pseudo-total) and aerial plant tissues. We found that As, Cd, Cr, Cu, Ni, Pb and Zn were higher than maximum regulatory limits. Element concentrations in plants were rather lower than expected, probably because indigenous plants have developed excluder behaviour over time. Copper and Zn soil-to-plant coefficients were highest among the other elements; for Cu this was unexpected, and probably associated with recent Cu-releasing industrial activity. Risk assessment analysis indicated that As was the element contributing more than 50 % of the health risk related to direct soil ingestion, followed by Cr, Pb, and, surprisingly, Mn. We concluded that in a multi-element contamination situation, elevated risk of PTEs (such as As, Cr and Pb) may reduce the tolerance limits of exposure to less-toxic elements (here, Mn).

  6. Hospitalizations Among Nursing Home Residents in the Last Year of Life: Nursing Home Characteristics and Variation in Potentially Avoidable Hospitalizations

    PubMed Central

    Xing, Jingping; Mukamel, Dana B.; Temkin-Greener, Helena

    2013-01-01

    Objectives 1) To examine the incidence, variations, and costs in potentially avoidable hospitalizations (PAHs) among nursing home (NH) residents at the end-of-life. 2) To identify the association between NH characteristics and a facility-level quality measure (QM) for PAH. Design Retrospective study. Setting Hospitalizations originating from NHs. Participants Long-term care NH residents who died in 2007. Measurements We constructed a risk-adjusted QM for PAH. Poisson regression model was used to predict the count of PAH given residents’ risk factors. For each facility, the QM was defined as the difference between the observed facility-specific rate (per 1,000 person-years) of PAH (O) and the expected risk-adjusted rate (E). We then fit a logistic regression model with state fixed-effects to examine the association between facility characteristics and the likelihood of having higher than expected rates of PAH (O-E>0). QM values higher than 0 indicate worse than average quality. Results Almost 50% of hospital admissions for NH residents in their last year of life were for potentially avoidable diagnoses, costing Medicare $1billion. Five conditions were responsible for over 80% of PAHs. PAH QM across facilities showed significant variation (mean=11.96; std dev=142.26; range: −399.48-398.09). Chain and hospital-based facilities were more likely to exhibit better performance (O-E<0). Facilities with higher nursing staffing were more likely to have better performance, as did facilities with higher skilled staff ratio, facilities with nurse practitioners/physician assistants, and those with on-site x-ray services. Conclusion Variations in facility-level PAHs suggest that a potential for reducing hospital admissions for these conditions may exist. Presence of modifiable facility characteristics associated with PAH performance provides insights into possible interventions for reducing PAHs at the end-of-life. PMID:24219191

  7. Association of hematological variables and castration status at the time of arrival at a research facility with the risk of bovine respiratory disease in beef calves

    USDA-ARS?s Scientific Manuscript database

    The objective of this study was to analyze the association between hematological parameters (CBC) and gender at stocker receiving facility arrival and the risk of subsequent clinical bovine respiratory disease (BRD) diagnosis, and (2) to determine and evaluate the accuracy of CBC parameter threshold...

  8. Risk factors for fecal colonization with multiple distinct strains of Escherichia coli among long-term care facility residents.

    PubMed

    Lautenbach, Ebbing; Tolomeo, Pam; Black, Nicole; Maslow, Joel N

    2009-05-01

    Of 49 long-term care facility residents, 21 (43%) were colonized with 2 or more distinct strains of Escherichia coli. There were no significant risk factors for colonization with multiple strains of E. coli. These results suggest that future efforts to efficiently identify the diversity of colonizing strains will be challenging.

  9. Risk Factors for Fecal Colonization with Multiple Distinct Strains of Escherichia coli Among Long-Term Care Facility Residents

    PubMed Central

    Lautenbach, Ebbing; Tolomeo, Pam; Black, Nicole; Maslow, Joel N.

    2009-01-01

    Of 49 long-term care facility residents, 21 (43%) were colonized with two or more distinct strains of Escherichia coli. There were no significant risk factors for colonization with multiple strains of E. coli. These results suggest future efforts to efficiently identify diversity of colonizing strains will be challenging. PMID:19292660

  10. An assessment of risk posed by a Campylobacter-positive puppy living in an Australian residential aged-care facility.

    PubMed

    Moffatt, Cameron; Appuhamy, Ranil; Andrew, Will; Wynn, Sandy; Roberts, Jan; Kennedy, Karina

    2014-01-01

    In April and June 2012, two outbreaks of Campylobacter gastroenteritis were investigated in an Australian aged-care facility (ACF); a Campylobacter-positive puppy was identified as a potential source of infection. An expert panel was convened to assess transmission risk from the puppy to elderly residents and to guide further public health action. Criteria considered as part of the panel's assessment included the puppy's infectivity, the bacterium's transmissibility, puppy-resident contact, infection control and cleaning practices and animal management at the facility. A literature review was used to assist the panel, with a final risk being determined using a likelihood and consequence matrix. The panel determined that the setting and low infective dose made transmission likely despite varying degrees of contact between the puppy and cases. While infection control practices were generally appropriate, the facility's animal policy did not adequately address potential zoonotic risk. In summary, puppies should not be considered as companion animals in ACFs due to high rates of Campylobacter carriage and the underlying susceptibility of the elderly. Infection control and animal policies in ACFs should reflect an awareness of zoonotic disease potential.

  11. Concept definition study for an extremely large aerophysics range facility

    NASA Technical Reports Server (NTRS)

    Swift, H.; Witcofski, R.

    1992-01-01

    The development of a large aerophysical ballistic range facility is considered to study large-scale hypersonic flows at high Reynolds numbers for complex shapes. A two-stage light gas gun is considered for the hypervelocity launcher, and the extensive range tankage is discussed with respect to blast suppression, model disposition, and the sabot impact tank. A layout is given for the large aerophysics facility, and illustrations are provided for key elements such as the guide rail. The paper shows that such a facility could be used to launch models with diameters approaching 250 mm at velocities of 6.5 km/s with peak achievable accelerations of not more than 85.0 kgs. The envisioned range would provide gas-flow facilities capable of controlling the modeled quiescent atmospheric conditions. The facility is argued to be a feasible and important step in the investigation and experiment of such hypersonic vehicles as the National Aerospace Plane.

  12. Removal site evaluation report for the Isotope Facilities at Oak Ridge National Laboratory, Oak Ridge, Tennessee

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    This removal site evaluation (RmSE) report of the Isotope Facilities at Oak Ridge National Laboratory (ORNL) was prepared to provide the Environmental Restoration Program with information necessary to evaluate whether hazardous and/or radiological contaminants in and around the Isotopes Facility pose a substantial risk to human health or the environment and if remedial site evaluations (RSEs) or removal actions are required. The scope of the project included: (1) a review of historical evidence regarding operations and use of the facility; (2) interviews with facility personnel concerning current and past operating practices; (3) a site inspection; and (4) identification of hazardmore » areas requiring maintenance, removal, or remedial actions. The results of RmSE indicate that no substantial risks exist from contaminants present in the Isotope Facilities because adequate controls and practices exist to protect human health and the environment. The recommended correction from the RmSE are being conducted as maintenance actions; accordingly, this RmSE is considered complete and terminated.« less

  13. WARP3D-Release 10.8: Dynamic Nonlinear Analysis of Solids using a Preconditioned Conjugate Gradient Software Architecture

    NASA Technical Reports Server (NTRS)

    Koppenhoefer, Kyle C.; Gullerud, Arne S.; Ruggieri, Claudio; Dodds, Robert H., Jr.; Healy, Brian E.

    1998-01-01

    This report describes theoretical background material and commands necessary to use the WARP3D finite element code. WARP3D is under continuing development as a research code for the solution of very large-scale, 3-D solid models subjected to static and dynamic loads. Specific features in the code oriented toward the investigation of ductile fracture in metals include a robust finite strain formulation, a general J-integral computation facility (with inertia, face loading), an element extinction facility to model crack growth, nonlinear material models including viscoplastic effects, and the Gurson-Tver-gaard dilatant plasticity model for void growth. The nonlinear, dynamic equilibrium equations are solved using an incremental-iterative, implicit formulation with full Newton iterations to eliminate residual nodal forces. The history integration of the nonlinear equations of motion is accomplished with Newmarks Beta method. A central feature of WARP3D involves the use of a linear-preconditioned conjugate gradient (LPCG) solver implemented in an element-by-element format to replace a conventional direct linear equation solver. This software architecture dramatically reduces both the memory requirements and CPU time for very large, nonlinear solid models since formation of the assembled (dynamic) stiffness matrix is avoided. Analyses thus exhibit the numerical stability for large time (load) steps provided by the implicit formulation coupled with the low memory requirements characteristic of an explicit code. In addition to the much lower memory requirements of the LPCG solver, the CPU time required for solution of the linear equations during each Newton iteration is generally one-half or less of the CPU time required for a traditional direct solver. All other computational aspects of the code (element stiffnesses, element strains, stress updating, element internal forces) are implemented in the element-by- element, blocked architecture. This greatly improves vectorization of the code on uni-processor hardware and enables straightforward parallel-vector processing of element blocks on multi-processor hardware.

  14. Assessing the risks of trace elements in environmental materials under selected greenhouse vegetable production systems of China.

    PubMed

    Chen, Yong; Huang, Biao; Hu, Wenyou; Weindorf, David C; Liu, Xiaoxiao; Niedermann, Silvana

    2014-02-01

    The risk assessment of trace elements of different environmental media in conventional and organic greenhouse vegetable production systems (CGVPS and OGVPS) can reveal the influence of different farming philosophy on the trace element accumulations and their effects on human health. These provide important basic data for the environmental protection and human health. This paper presents trace element accumulation characteristics of different land uses; reveals the difference of soil trace element accumulation both with and without consideration of background levels; compares the trace element uptake by main vegetables; and assesses the trace element risks of soils, vegetables, waters and agricultural inputs, using two selected greenhouse vegetable systems in Nanjing, China as examples. Results showed that greenhouse vegetable fields contained significant accumulations of Zn in CGVPS relative to rice-wheat rotation fields, open vegetable fields, and geochemical background levels, and this was the case for organic matter in OGVPS. The comparative analysis of the soil medium in two systems with consideration of geochemical background levels and evaluation of the geo-accumulation pollution index achieved a more reasonable comparison and accurate assessment relative to the direct comparison analysis and the evaluation of the Nemerow pollution index, respectively. According to the Chinese food safety standards and the value of the target hazard quotient or hazard index, trace element contents of vegetables were safe for local residents in both systems. However, the spatial distribution of the estimated hazard index for producers still presented certain specific hotspots which may cause potential risk for human health in CGVPS. The water was mainly influenced by nitrogen, especially for CGVPS, while the potential risk of Cd and Cu pollution came from sediments in OGVPS. The main inputs for trace elements were fertilizers which were relatively safe based on relevant standards; but excess application caused trace element accumulations in the environmental media. Copyright © 2013 Elsevier B.V. All rights reserved.

  15. Spatiotemporal Characteristics and Health Risk Assessment of Heavy Metals in PM2.5 in Zhejiang Province

    PubMed Central

    Wang, Xiaofeng; He, Shengliang; Chen, Shuchang; Zhang, Yongli; Wang, Aihong; Luo, Jinbin; Ye, Xialiang; Mo, Zhe; Wu, Lizhi; Xu, Peiwei; Cai, Gaofeng; Chen, Zhijian; Lou, Xiaoming

    2018-01-01

    The spatiotemporal characteristics and human health risks of 12 heavy metals (Al, As, Be, Cd, Cr, Hg, Mn, Ni, Pb, Sb, Se, and Tl) in fine particulate matter (PM2.5) in Zhejiang Province were investigated. The annual average PM2.5 concentration was 58.83 µg/m3 in 2015 in Zhejiang. Element contents in PM2.5 varied greatly with the season and locations. Al, Pb, and Mn were the most abundant elements among the studied metal(loid)s in PM2.5. The non-carcinogenic risks of the 12 elements through inhalation and dermal contact exposure were lower than the safe level for children and adults. However, there were potential non-carcinogenic risks of Tl, As, and Sb for children and Tl for adults through ingestion exposure. The carcinogenic risks from As, Be, Cd, Cr, Pb, and Ni through inhalation exposure were less than the acceptable level (1 × 10−4) for children and adults. Pb may carry a potential carcinogenic risk for both children and adults through ingestion. More attention should be paid to alleviate non-carcinogenic and carcinogenic health risks posed by particle-bound toxic elements through ingestion exposure. PMID:29587346

  16. Pressure ulcer prevention in long-term-care facilities: a pilot study implementing standardized nurse aide documentation and feedback reports.

    PubMed

    Horn, Susan D; Sharkey, Siobhan S; Hudak, Sandra; Gassaway, Julie; James, Roberta; Spector, William

    2010-03-01

    To design and facilitate implementation of practice-based evidence changes associated with decreases in pressure ulcer (PrU) development in long-term-care (LTC) facilities and promote these practices as part of routine care. Pre/post observational study. Frail older adult residents in 11 US LTC facilities. Project facilitators assisted frontline multidisciplinary teams (certified nurse aides [CNAs], nurses, and dietitians/dietary aides) to develop streamlined standardized CNA documentation and weekly reports to identify high-risk residents and to integrate clinical reports into day-to-day practice and clinical decision making. The program was called "Real-Time Optimal Care Plans for Nursing Home QI" (Real-Time). Prevalence of PrUs using Centers for Medicare & Medicaid Services (CMS) quality measures (QMs), number of in-house-acquired PrUs, and number and completeness of CNA documentation forms. Seven study LTC facilities that reported data to CMS experienced a combined 33% (SD, 36.1%) reduction in the CMS high-risk PrU QM in 18 months and reduction in newly occurring PrUs (number of ulcers in the fourth quarter of 2003: range, 2-19; and in the third quarter of 2005: range, 1-6). Five of these LTC facilities that fully implemented Real-Time experienced a combined 48.1% (SD, 23.4%) reduction in the CMS high-risk PrU QM. Ten facilities reduced by an average of 2 to 5 their number of CNA documentation forms; CNA weekly documentation completeness reached a consistent level of 90% to 95%, and 8 facilities integrated the use of 2 to 4 weekly project reports in routine clinical decision making. Quality improvement efforts that provide access to focused and timely clinical information, facilitate change, and promote staff working together in multidisciplinary teams impacted clinical outcomes. Prevention of PrUs showed a trend of improvement in facilities that fully integrated tools to identify high-risk residents into day-to-day practice. CNA documentation facilitated better information for clinical decision making. More than 70 additional LTC facilities across the United States are implementing this QI program.

  17. Marketing in the long-term care continuum.

    PubMed

    Laurence, J Nathan; Kash, Bita A

    2010-04-01

    Today, long-term care facilities are composed of independent, assisted living, and skilled nursing facilities along with many variations of those themes in between. The clientele for these various types of facilities differ because of the level of care the facility provides as well as the amenities long-term care consumers are looking for. However, there many similarities and common approaches to how reaching the target audience through effective marketing activities. Knowing who the target audience is, how to reach them, and how to communicate with them will serve any facility well in this competitive market. Developing marketing strategies for long-term care settings is as important as understanding what elements of care can be marketed individually as a niche market. Determining the market base for a facility is equally crucial since the target populations differ among the three types of facilities. By reviewing current marketing articles and applying marketing practices, we have crafted some general principles for which each facility type can learn from. Finally, we will discuss the types of marketing and how they related to the spectrum of long-term care facilities.

  18. 40 CFR 1400.5 - Internet access to certain off-site consequence analysis data elements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... AGENCY AND DEPARTMENT OF JUSTICE ACCIDENTAL RELEASE PREVENTION REQUIREMENTS; RISK MANAGEMENT PROGRAMS... elements in the risk management plan database available on the Internet: (a) The concentration of the...

  19. [Considering the current state of fire safety in Taiwan's care environment from the perspective of the nation's worst recent hospital fire].

    PubMed

    Tseng, Wei-Wen; Shih, Chung-Liang; Chien, Shen-Wen

    2013-04-01

    Taiwan's worst hospital fire in history on October 23rd, 2012 at Sinying Hospital's Bei-Men Branch resulted in 13 elderly patient deaths and over 70 injuries. The heavy casualties were due in part to the serious condition of patients. Some patients on life-support machines were unable to move or be moved. This disaster highlights the issue of fire safety in small-scale hospitals that have transformed existing hospital space into special care environments for elderly patients. Compared with medical centers and general hospitals, these small-scale health facilities are ill equipped to deal properly with fire safety management and emergency response issues due to inadequate fire protection facilities, fire safety equipment, and human resources. Small-scale facilities that offer health care and medical services to mostly immobile patients face fire risks that differ significantly from general health care facilities. This paper focuses on fire risks in small-scale facilities and suggests a strategy for fire prevention and emergency response procedures, including countermeasures for fire risk assessment, management, and emergency response, in order to improve fire safety at these institutions in Taiwan.

  20. Suicide Risk in Nursing Homes and Assisted Living Facilities: 2003-2011.

    PubMed

    Mezuk, Briana; Lohman, Matthew; Leslie, Marc; Powell, Virginia

    2015-07-01

    We investigated the epidemiology of suicide among adults aged 50 years and older in nursing homes and assisted living facilities and whether anticipating transitioning into long-term care (LTC) is a risk factor for suicide. Data come from the Virginia Violent Death Reporting System (2003-2011). We matched locations of suicides (n = 3453) against publicly available resource registries of nursing homes (n = 285) and assisted living facilities (n = 548). We examined individual and organizational correlates of suicide by logistic regression. We identified decedents anticipating entry into LTC through qualitative text analysis. Incidence of suicide was 14.16 per 100 000 in nursing homes and 15.66 in the community. Better performance on Nursing Home Compare quality metrics was associated with higher odds of suicide in nursing homes (odds ratio [OR] = 1.95; 95% confidence interval [CI] = 1.21, 3.14). Larger facility size was associated with higher suicide risk in assisted living facilities (OR = 1.01; 95% CI = 1.00, 1.01). Text narratives identified 38 decedents anticipating transitioning into LTC and 16 whose loved one recently transitioned or resided in LTC. LTC may be an important point of engagement in suicide prevention.

  1. Health Care Facilities Resilient to Climate Change Impacts

    PubMed Central

    Paterson, Jaclyn; Berry, Peter; Ebi, Kristie; Varangu, Linda

    2014-01-01

    Climate change will increase the frequency and magnitude of extreme weather events and create risks that will impact health care facilities. Health care facilities will need to assess climate change risks and adopt adaptive management strategies to be resilient, but guidance tools are lacking. In this study, a toolkit was developed for health care facility officials to assess the resiliency of their facility to climate change impacts. A mixed methods approach was used to develop climate change resiliency indicators to inform the development of the toolkit. The toolkit consists of a checklist for officials who work in areas of emergency management, facilities management and health care services and supply chain management, a facilitator’s guide for administering the checklist, and a resource guidebook to inform adaptation. Six health care facilities representing three provinces in Canada piloted the checklist. Senior level officials with expertise in the aforementioned areas were invited to review the checklist, provide feedback during qualitative interviews and review the final toolkit at a stakeholder workshop. The toolkit helps health care facility officials identify gaps in climate change preparedness, direct allocation of adaptation resources and inform strategic planning to increase resiliency to climate change. PMID:25522050

  2. Fluids and Combustion Facility: Combustion Integrated Rack Modal Model Correlation

    NASA Technical Reports Server (NTRS)

    McNelis, Mark E.; Suarez, Vicente J.; Sullivan, Timothy L.; Otten, Kim D.; Akers, James C.

    2005-01-01

    The Fluids and Combustion Facility (FCF) is a modular, multi-user, two-rack facility dedicated to combustion and fluids science in the US Laboratory Destiny on the International Space Station. FCF is a permanent facility that is capable of accommodating up to ten combustion and fluid science investigations per year. FCF research in combustion and fluid science supports NASA's Exploration of Space Initiative for on-orbit fire suppression, fire safety, and space system fluids management. The Combustion Integrated Rack (CIR) is one of two racks in the FCF. The CIR major structural elements include the International Standard Payload Rack (ISPR), Experiment Assembly (optics bench and combustion chamber), Air Thermal Control Unit (ATCU), Rack Door, and Lower Structure Assembly (Input/Output Processor and Electrical Power Control Unit). The load path through the rack structure is outlined. The CIR modal survey was conducted to validate the load path predicted by the CIR finite element model (FEM). The modal survey is done by experimentally measuring the CIR frequencies and mode shapes. The CIR model was test correlated by updating the model to represent the test mode shapes. The correlated CIR model delivery is required by NASA JSC at Launch-10.5 months. The test correlated CIR flight FEM is analytically integrated into the Shuttle for a coupled loads analysis of the launch configuration. The analysis frequency range of interest is 0-50 Hz. A coupled loads analysis is the analytical integration of the Shuttle with its cargo element, the Mini Payload Logistics Module (MPLM), in the Shuttle cargo bay. For each Shuttle launch configuration, a verification coupled loads analysis is performed to determine the loads in the cargo bay as part of the structural certification process.

  3. KSC01pp0413

    NASA Image and Video Library

    2001-02-19

    In the Spacecraft Assembly and Encapsulation Facility 2, a Russian scientist (SAEF-2) looks over the High Energy Neutron Detector (HEND), part of the Gamma Ray Spectrometer (GRS), after its removal from the 2001 Mars Odyssey Orbiter. The HEND was built by Russia’s Space Research Institute (IKI). The GRS will achieve global mapping of the elemental composition of the surface and determine the abundance of hydrogen in the shallow subsurface. The orbiter will carry two other science instruments: THEMIS and the Mars Radiation Environment Experiment (MARIE). THEMIS will map the mineralogy and morphology of the Martian surface using a high-resolution camera and a thermal infrared imaging spectrometer. The MARIE will characterize aspects of the near-space radiation environment with regards to the radiation-related risk to human explorers. The Mars Odyssey Orbiter is scheduled for launch April 7, 2001, aboard a Delta 7925 rocket from Launch Pad 17-A, Cape Canaveral Air Force Station

  4. KSC01pp0412

    NASA Image and Video Library

    2001-02-19

    In the Spacecraft Assembly and Encapsulation Facility 2 (SAEF-2), a worker removes the High Energy Neutron Detector (HEND), part of the Gamma Ray Spectrometer (GRS), from the 2001 Mars Odyssey Orbiter. The HEND was built by Russia’s Space Research Institute (IKI). The GRS will achieve global mapping of the elemental composition of the surface and determine the abundance of hydrogen in the shallow subsurface. The orbiter will carry two other science instruments: THEMIS and the Mars Radiation Environment Experiment (MARIE). THEMIS will map the mineralogy and morphology of the Martian surface using a high-resolution camera and a thermal infrared imaging spectrometer. The MARIE will characterize aspects of the near-space radiation environment with regards to the radiation-related risk to human explorers. The Mars Odyssey Orbiter is scheduled for launch April 7, 2001, aboard a Delta 7925 rocket from Launch Pad 17-A, Cape Canaveral Air Force Station

  5. KSC01pp0411

    NASA Image and Video Library

    2001-02-19

    In the Spacecraft Assembly and Encapsulation Facility 2 (SAEF-2), workers prepare to remove the High Energy Neutron Detector (HEND), part of the Gamma Ray Spectrometer (GRS), from the 2001 Mars Odyssey Orbiter. The HEND was built by Russia’s Space Research Institute (IKI). The GRS will achieve global mapping of the elemental composition of the surface and determine the abundance of hydrogen in the shallow subsurface. The orbiter will carry two other science instruments: THEMIS and the Mars Radiation Environment Experiment (MARIE). THEMIS will map the mineralogy and morphology of the Martian surface using a high-resolution camera and a thermal infrared imaging spectrometer. The MARIE will characterize aspects of the near-space radiation environment with regards to the radiation-related risk to human explorers. The Mars Odyssey Orbiter is scheduled for launch April 7, 2001, aboard a Delta 7925 rocket from Launch Pad 17-A, Cape Canaveral Air Force Station

  6. Recommended techniques for effective maintainability. A continuous improvement initiative of the NASA Reliability and Maintainability Steering Committee

    NASA Technical Reports Server (NTRS)

    1994-01-01

    This manual presents a series of recommended techniques that can increase overall operational effectiveness of both flight and ground based NASA systems. It provides a set of tools that minimizes risk associated with: (1) restoring failed functions (both ground and flight based); (2) conducting complex and highly visible maintenance operations; and (3) sustaining a technical capability to support the NASA mission using aging equipment or facilities. It considers (1) program management - key elements of an effective maintainability effort; (2) design and development - techniques that have benefited previous programs; (3) analysis and test - quantitative and qualitative analysis processes and testing techniques; and (4) operations and operational design techniques that address NASA field experience. This document is a valuable resource for continuous improvement ideas in executing the systems development process in accordance with the NASA 'better, faster, smaller, and cheaper' goal without compromising safety.

  7. Requirements for significant problem reporting and trend analysis

    NASA Technical Reports Server (NTRS)

    1988-01-01

    This handbook supplements policies, requirements, and procedures of NMI 8070.3 to ensure that NASA management at each organizational level is: fully aware of trends affecting both the level of safety and the potential for mission success established for both NASA manned space programs and its supporting institutions; fully and independently informed of problems that represent significant risk to the safety of all personnel (including the general populace) and to the success of a mission or operation through a program mechanism herein defined as Significant Problem Reporting; and in full agreement with the level of elimination of these problems through the closed-loop accounting of corrective actions. The requirements of this handbook are supportive of the agency's safety, reliability, maintainability, and quality assurance (SRM&QA) program objectives and are applicable to all organizational elements of NASA connected with or supporting developmental or operational manned space program/projects (including associated payloads) and the related institutional facilities.

  8. KSC01pp0158

    NASA Image and Video Library

    2001-01-09

    Workers in the Spacecraft Assembly & Encapsulation Facility -2 open the solar array panels from the 2001 Mars Odyssey Orbiter, allowing inspection of the panels and giving them access to other components. The Mars Odyssey carries three science instruments: the Thermal Emission Imaging System (THEMIS), the Gamma Ray Spectrometer (GRS), and the Mars Radiation Environment Experiment (MARIE). THEMIS will map the mineralogy and morphology of the Martian surface using a high-resolution camera and a thermal infrared imaging spectrometer. The GRS will achieve global mapping of the elemental composition of the surface and determine the abundance of hydrogen in the shallow subsurface. [The GRS is a rebuild of the instrument lost with the Mars Observer mission.] The MARIE will characterize aspects of the near-space radiation environment as related to the radiation-related risk to human explorers. The Mars Odyssey Orbiter is scheduled for launch on April 7, 2001, aboard a Delta 7925 rocket from Launch Pad 17-A, Cape Canaveral Air Force Station

  9. How to implement security controls for an information security program at CBRN facilities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lenaeus, Joseph D.; O'Neil, Lori Ross; Leitch, Rosalyn M.

    This document was prepared by PNNL within the framework of Project 19 of the European Union Chemical Biological Radiological and Nuclear Risk Mitigation Centres of Excellence Initiative entitled, ''Development of procedures and guidelines to create and improve secure information management systems and data exchange mechanisms for CBRN materials under regulatory control.'' It provides management and workers at CBRN facilities, parent organization managers responsible for those facilities, and regulatory agencies (governmental and nongovernmental) with guidance on the best practices for protecting information security. The security mitigation approaches presented in this document were chosen because they present generally accepted guidance in anmore » easy-to-understand manner, making it easier for facility personnel to grasp key concepts and envision how security controls could be implemented by the facility. This guidance is presented from a risk management perspective.« less

  10. Buffet test in the National Transonic Facility

    NASA Technical Reports Server (NTRS)

    Young, Clarence P., Jr.; Hergert, Dennis W.; Butler, Thomas W.; Herring, Fred M.

    1992-01-01

    A buffet test of a commercial transport model was accomplished in the National Transonic Facility at the NASA Langley Research Center. This aeroelastic test was unprecedented for this wind tunnel and posed a high risk for the facility. Presented here are the test results from a structural dynamics and aeroelastic response point of view. The activities required for the safety analysis and risk assessment are described. The test was conducted in the same manner as a flutter test and employed on-board dynamic instrumentation, real time dynamic data monitoring, and automatic and manual tunnel interlock systems for protecting the model.

  11. Medicare and Medicaid: long-term care survey--HCFA. Final rule.

    PubMed

    1988-06-17

    This final rule amends the Medicare and Medicaid regulations to require that the State survey agencies use the survey methods and procedures prescribed by HCFA and forms contained in regulations. The regulations define the principles on which Medicare and Medicaid survey methodologies are based and the required elements of a skilled nursing facility (SNF) or intermediate care facility (ICF) survey. This rule is in response to a court order.

  12. ICIS-Air Download Summary and Data Element Dictionary ...

    EPA Pesticide Factsheets

    ECHO, Enforcement and Compliance History Online, provides compliance and enforcement information for approximately 800,000 EPA-regulated facilities nationwide. ECHO includes permit, inspection, violation, enforcement action, and penalty information about facilities regulated under the Clean Air Act (CAA) Stationary Source Program, Clean Water Act (CWA) National Pollutant Elimination Discharge System (NPDES), and/or Resource Conservation and Recovery Act (RCRA). Information also is provided on surrounding demographics when available.

  13. ICIS-FE&C Download Summary and Data Element Dictionary ...

    EPA Pesticide Factsheets

    ECHO, Enforcement and Compliance History Online, provides compliance and enforcement information for approximately 800,000 EPA-regulated facilities nationwide. ECHO includes permit, inspection, violation, enforcement action, and penalty information about facilities regulated under the Clean Air Act (CAA) Stationary Source Program, Clean Water Act (CWA) National Pollutant Elimination Discharge System (NPDES), and/or Resource Conservation and Recovery Act (RCRA). Information also is provided on surrounding demographics when available.

  14. US Naval Facilities Engineering Service Center Environmental Program on Climate Change

    DTIC Science & Technology

    2008-09-01

    of environmental issues related to climate change . There is a growing recognition that the Navy will need to perform its national security mission in... climate change -related technology work at the Naval Facilities Engineering Service Center (NAVFAC ESC) in Port Hueneme, California. NAVFAC ESC...categorized technologies that can be applied to climate change as mitigation, adaptation, and intervention. An essential element of the Navy’s response to

  15. ICIS-NPDES Limit Summary and Data Element Dictionary ...

    EPA Pesticide Factsheets

    ECHO, Enforcement and Compliance History Online, provides compliance and enforcement information for approximately 800,000 EPA-regulated facilities nationwide. ECHO includes permit, inspection, violation, enforcement action, and penalty information about facilities regulated under the Clean Air Act (CAA) Stationary Source Program, Clean Water Act (CWA) National Pollutant Elimination Discharge System (NPDES), and/or Resource Conservation and Recovery Act (RCRA). Information also is provided on surrounding demographics when available.

  16. ICIS-NPDES DMR Summary and Data Element Dictionary ...

    EPA Pesticide Factsheets

    ECHO, Enforcement and Compliance History Online, provides compliance and enforcement information for approximately 800,000 EPA-regulated facilities nationwide. ECHO includes permit, inspection, violation, enforcement action, and penalty information about facilities regulated under the Clean Air Act (CAA) Stationary Source Program, Clean Water Act (CWA) National Pollutant Elimination Discharge System (NPDES), and/or Resource Conservation and Recovery Act (RCRA). Information also is provided on surrounding demographics when available.

  17. KENNEDY SPACE CENTER, FLA. - Members of the STS-114 crew take a look at the Japanese Experiment Module (JEM) pressure module in the Space Station Processing Facility. A research laboratory, the pressurized module is the first element of the JEM, named "Kibo" (Hope), to be delivered to KSC. The National Space Development Agency of Japan (NASDA) developed the laboratory at the Tsukuba Space Center near Tokyo and is Japan's primary contribution to the Station. The JEM also includes an exposed facility (platform) for space environment experiments, a robotic manipulator system, and two logistics modules. The various JEM components will be assembled in space over the course of three Shuttle missions.

    NASA Image and Video Library

    2003-06-09

    KENNEDY SPACE CENTER, FLA. - Members of the STS-114 crew take a look at the Japanese Experiment Module (JEM) pressure module in the Space Station Processing Facility. A research laboratory, the pressurized module is the first element of the JEM, named "Kibo" (Hope), to be delivered to KSC. The National Space Development Agency of Japan (NASDA) developed the laboratory at the Tsukuba Space Center near Tokyo and is Japan's primary contribution to the Station. The JEM also includes an exposed facility (platform) for space environment experiments, a robotic manipulator system, and two logistics modules. The various JEM components will be assembled in space over the course of three Shuttle missions.

  18. User satisfaction level of parking space facility: a case of Faculty of Geography, Universitas Gadjah Mada, Indonesia

    NASA Astrophysics Data System (ADS)

    Budiani, S. R.; Iffani, M.; Novianti, I.; Alfana, M. A. F.; Harini, R.; Rofi, A.

    2018-04-01

    Every vehicular trip starts and finishes at a parking lot. Therefore, the availability of parking space has to meet the demand of vehicle users so that their activities can be performed smoothly and in time. The needs for parking space in Faculty of Geography tend to increase from year to year due to the increasing use of private vehicles in the faculty. This research aimed to identify the user satisfaction level of the parking space in Faculty of geography and to understand the influence of the parking facility on user satisfaction level. It was survey research because it took samples from a population and used a list of questions as a data collection tool. The data was analyzed quantitatively with descriptive statistics. The satisfaction level was calculated according to an existing regulation, namely the Decree of the Indonesian Minister of Administrative and Bureaucratic Reform No. Kep/25/M.PAN/2004 about General Guidelines for the Assessment of Community Satisfaction Index of Public Service Unit. The results showed that the mean user satisfaction level of the parking facility and each of its elements were good. In other words, the parking facility was already good in each element. Therefore, the faculty should focus the improvement on making it better.

  19. The MHOST finite element program: 3-D inelastic analysis methods for hot section components. Volume 3: Systems' manual

    NASA Technical Reports Server (NTRS)

    Nakazawa, Shohei

    1989-01-01

    The internal structure is discussed of the MHOST finite element program designed for 3-D inelastic analysis of gas turbine hot section components. The computer code is the first implementation of the mixed iterative solution strategy for improved efficiency and accuracy over the conventional finite element method. The control structure of the program is covered along with the data storage scheme and the memory allocation procedure and the file handling facilities including the read and/or write sequences.

  20. Japanese experiment module (JEM)

    NASA Technical Reports Server (NTRS)

    Kato, T.

    1986-01-01

    Japanese hardware elements studied during the definition phase of phase B are described. The hardware is called JEM (Japanese Experiment Module) and will be attached to the Space Station core. JEM consists of a pressurized module, an exposed facility, a scientific/equipment airlock, a local remote manipulator, and experimental logistic module. With all those hardware elements JEM will accommodate general scientific and technology development research (some of the elements are to utilize the advantage of the microgravity environment), and also accommodate control panels for the Space Station Mobile Remote Manipulator System and attached payloads.

  1. Aerial photos of KSC

    NASA Technical Reports Server (NTRS)

    2000-01-01

    Looking northeast, several elements of the Shuttle Landing Facility (SLF) can be seen. The road on the bottom left corner is the tow-way road, connecting the Orbiter Processing Facility with the landing strip, seen at upper left. The building in the center is the remote launch vehicle (RLV) hangar, still under construction, at the south end of the SLF. Next to the multi- purpose RLV hangar are facilities for related ground support equipment and administrative/technical support. Beyond them is the parking tarmac with its mate-demate device. The lush grounds of the Merritt Island National Wildlife Refuge, which shares a boundary with KSC, extend beyond.

  2. Occurrence and health risk assessment of selected metals in drinking water from two typical remote areas in China.

    PubMed

    Geng, Menghan; Qi, Hongjuan; Liu, Xuelin; Gao, Bo; Yang, Zhan; Lu, Wei; Sun, Rubao

    2016-05-01

    The potential contaminations of 16 trace elements (Cr, Mn, Ni, Cu, Zn, As, Cd, Sb, Ba, Pb, Co, Be, V, Ti, Tl, Al) in drinking water collected in two remote areas in China were analyzed. The average levels of the trace elements were lower than the allowable concentrations set by national agencies, except for several elements (As, Sb, Mn, and Be) in individual samples. A health risk assessment model was conducted and carcinogenic and non-carcinogenic risks were evaluated separately. The results indicated that the total carcinogenic risks were higher than the maximum allowed risk level set by most organizations (1 × 10(-6)). Residents in both study areas were at risk of carcinogenic effects from exposure to Cr, which accounted for 80-90 % of the total carcinogenic risks. The non-carcinogenic risks (Cu, Zn, Ni) were lower than the maximum allowance levels. Among the four population groups, infants incurred the highest health risks and required special attention. Correlation analysis revealed significant positive associations among most trace elements, indicating the likelihood of a common source. The results of probabilistic health risk assessment of Cr based on Monte-Carlo simulation revealed that the uncertainty of system parameters does not affect the decision making of pollution prevention and control. Sensitivity analysis revealed that ingestion rate of water and concentration of Cr showed relatively high sensitivity to the health risks.

  3. Sanitation and Hygiene-Specific Risk Factors for Moderate-to-Severe Diarrhea in Young Children in the Global Enteric Multicenter Study, 2007-2011: Case-Control Study.

    PubMed

    Baker, Kelly K; O'Reilly, Ciara E; Levine, Myron M; Kotloff, Karen L; Nataro, James P; Ayers, Tracy L; Farag, Tamer H; Nasrin, Dilruba; Blackwelder, William C; Wu, Yukun; Alonso, Pedro L; Breiman, Robert F; Omore, Richard; Faruque, Abu S G; Das, Sumon Kumar; Ahmed, Shahnawaz; Saha, Debasish; Sow, Samba O; Sur, Dipika; Zaidi, Anita K M; Quadri, Fahreen; Mintz, Eric D

    2016-05-01

    Diarrheal disease is the second leading cause of disease in children less than 5 y of age. Poor water, sanitation, and hygiene conditions are the primary routes of exposure and infection. Sanitation and hygiene interventions are estimated to generate a 36% and 48% reduction in diarrheal risk in young children, respectively. Little is known about whether the number of households sharing a sanitation facility affects a child's risk of diarrhea. The objective of this study was to describe sanitation and hygiene access across the Global Enteric Multicenter Study (GEMS) sites in Africa and South Asia and to assess sanitation and hygiene exposures, including shared sanitation access, as risk factors for moderate-to-severe diarrhea (MSD) in children less than 5 y of age. The GEMS matched case-control study was conducted between December 1, 2007, and March 3, 2011, at seven sites in Basse, The Gambia; Nyanza Province, Kenya; Bamako, Mali; Manhiça, Mozambique; Mirzapur, Bangladesh; Kolkata, India; and Karachi, Pakistan. Data was collected for 8,592 case children aged <5 y old experiencing MSD and for 12,390 asymptomatic age, gender, and neighborhood-matched controls. An MSD case was defined as a child with a diarrheal illness <7 d duration comprising ≥3 loose stools in 24 h and ≥1 of the following: sunken eyes, skin tenting, dysentery, intravenous (IV) rehydration, or hospitalization. Site-specific conditional logistic regression models were used to explore the association between sanitation and hygiene exposures and MSD. Most households at six sites (>93%) had access to a sanitation facility, while 70% of households in rural Kenya had access to a facility. Practicing open defecation was a risk factor for MSD in children <5 y old in Kenya. Sharing sanitation facilities with 1-2 or ≥3 other households was a statistically significant risk factor for MSD in Kenya, Mali, Mozambique, and Pakistan. Among those with a designated handwashing area near the home, soap or ash were more frequently observed at control households and were significantly protective against MSD in Mozambique and India. This study suggests that sharing a sanitation facility with just one to two other households can increase the risk of MSD in young children, compared to using a private facility. Interventions aimed at increasing access to private household sanitation facilities may reduce the burden of MSD in children. These findings support the current World Health Organization/ United Nations Children's Emergency Fund (UNICEF) system that categorizes shared sanitation as unimproved.

  4. Evaluation of the use of oseltamivir prophylaxis in the control of influenza outbreaks in long-term care facilities in Alberta, Canada: a retrospective provincial database analysis

    PubMed Central

    Ye, Ming; Jacobs, Angela; Khan, Muhammad Naeem; Jaipaul, Joy; Oda, Joanna; Johnson, Marcia; Doroshenko, Alexander

    2016-01-01

    Objectives To evaluate the impact of oseltamivir prophylaxis in the management and control of influenza outbreaks in long-term care facilities in Alberta, Canada. Setting and participants Long-term care facilities where 127 influenza outbreaks were reported to public health authorities in Alberta, Canada, during two influenza seasons from 2013 to 2015. Design and outcome measures Using routinely collected surveillance and administrative data, we examined the association between decision-making time for oseltamivir recommendation as prophylaxis strategy for influenza outbreaks in long-term care facilities (explanatory variable) and the duration of an influenza outbreak, the postprophylaxis risk of influenza-like illness and hospitalisation among residents of long-term care facilities in Alberta (outcome variables) using multivariable linear and Poisson regression models. Results Oseltamivir prophylaxis decision-making time was positively associated with the postintervention duration of an outbreak, with a 1-day delay in making decision on oseltamivir prophylaxis associated with 2.22 (95% CI 1.37 to 3.06) more days of the duration of an outbreak after controlling for potential confounding effect of the number of residents at risk at intervention, outbreak progression time, prevalence of influenza-like illness during outbreak progression, facility location, presence of mixed strain and based on optimal timing of oseltamivir prophylaxis. Although not statistically significant, a 1-day delay in making decision on oseltamivir prophylaxis was associated with a 5% (95% CI −1% to 11%) increase in the postintervention risk of influenza-like illness, and a 6% (95% CI −8% to 22%) increase in the postintervention risk of hospitalisation after controlling for the same potential confounders. Conclusions Our study demonstrated benefits of using oseltamivir prophylaxis to shorten the duration of influenza outbreaks; however, there were no significant differences in the influenza-like illness and hospitalisation risk occurring after the intervention. Surveillance data may offer means of rapid evaluation of oseltamivir prophylaxis in long-term care facilities as a public health measure. PMID:27381211

  5. Evaluation of the use of oseltamivir prophylaxis in the control of influenza outbreaks in long-term care facilities in Alberta, Canada: a retrospective provincial database analysis.

    PubMed

    Ye, Ming; Jacobs, Angela; Khan, Muhammad Naeem; Jaipaul, Joy; Oda, Joanna; Johnson, Marcia; Doroshenko, Alexander

    2016-07-05

    To evaluate the impact of oseltamivir prophylaxis in the management and control of influenza outbreaks in long-term care facilities in Alberta, Canada. Long-term care facilities where 127 influenza outbreaks were reported to public health authorities in Alberta, Canada, during two influenza seasons from 2013 to 2015. Using routinely collected surveillance and administrative data, we examined the association between decision-making time for oseltamivir recommendation as prophylaxis strategy for influenza outbreaks in long-term care facilities (explanatory variable) and the duration of an influenza outbreak, the postprophylaxis risk of influenza-like illness and hospitalisation among residents of long-term care facilities in Alberta (outcome variables) using multivariable linear and Poisson regression models. Oseltamivir prophylaxis decision-making time was positively associated with the postintervention duration of an outbreak, with a 1-day delay in making decision on oseltamivir prophylaxis associated with 2.22 (95% CI 1.37 to 3.06) more days of the duration of an outbreak after controlling for potential confounding effect of the number of residents at risk at intervention, outbreak progression time, prevalence of influenza-like illness during outbreak progression, facility location, presence of mixed strain and based on optimal timing of oseltamivir prophylaxis. Although not statistically significant, a 1-day delay in making decision on oseltamivir prophylaxis was associated with a 5% (95% CI -1% to 11%) increase in the postintervention risk of influenza-like illness, and a 6% (95% CI -8% to 22%) increase in the postintervention risk of hospitalisation after controlling for the same potential confounders. Our study demonstrated benefits of using oseltamivir prophylaxis to shorten the duration of influenza outbreaks; however, there were no significant differences in the influenza-like illness and hospitalisation risk occurring after the intervention. Surveillance data may offer means of rapid evaluation of oseltamivir prophylaxis in long-term care facilities as a public health measure. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  6. Quantitative comparison between PGNAA measurements and MCNP calculations in view of the characterization of radioactive wastes in Germany and France

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mauerhofer, E.; Havenith, A.; Kettler, J.

    The Forschungszentrum Juelich GmbH (FZJ), together with the Aachen University Rheinisch-Westfaelische Technische Hochschule (RWTH) and the French Alternative Energies and Atomic Energy Commission (CEA Cadarache) are involved in a cooperation aiming at characterizing toxic and reactive elements in radioactive waste packages by means of Prompt Gamma Neutron Activation Analysis (PGNAA). The French and German waste management agencies have indeed defined acceptability limits concerning these elements in view of their projected geological repositories. A first measurement campaign was performed in the new Prompt Gamma Neutron Activation Analysis (PGNAA) facility called MEDINA, at FZJ, to assess the capture gamma-ray signatures of somemore » elements of interest in large samples up to waste drums with a volume of 200 liter. MEDINA is the acronym for Multi Element Detection based on Instrumental Neutron Activation. This paper presents MCNP calculations of the MEDINA facility and quantitative comparison between measurement and simulation. Passive gamma-ray spectra acquired with a high purity germanium detector and calibration sources are used to qualify the numerical model of the crystal. Active PGNAA spectra of a sodium chloride sample measured with MEDINA then allow for qualifying the global numerical model of the measurement cell. Chlorine indeed constitutes a usual reference with reliable capture gamma-ray production data. The goal is to characterize the entire simulation protocol (geometrical model, nuclear data, and postprocessing tools) which will be used for current measurement interpretation, extrapolation of the performances to other types of waste packages or other applications, as well as for the study of future PGNAA facilities.« less

  7. The uses of synchrotron radiation sources for elemental and chemical microanalysis

    USGS Publications Warehouse

    Chen, J.R.; Chao, E.C.T.; Minkin, J.A.; Back, J.M.; Jones, K.W.; Rivers, M.L.; Sutton, S.R.

    1990-01-01

    Synchrotron radiation sources offer important features for the analysis of a material. Among these features is the ability to determine both the elemental composition of the material and the chemical state of its elements. For microscopic analysis synchrotron X-ray fluorescence (SXRF) microprobes now offer spatial resolutions of 10 ??m with minimum detection limits in the 1-10 ppm range depending on the nature of the sample and the synchrotron source used. This paper describes the properties of synchrotron radiation and their importance for elemental analysis, existing synchrotron facilities and those under construction that are optimum for SXRF microanalysis, and a number of applications including the high energy excitation of the K lines of heavy elements, microtomography, and XANES and EXAFS spectroscopies. ?? 1990.

  8. Ambient air quality at the wider area of an industrial mining facility at Stratoni, Chalkidiki, Greece.

    PubMed

    Gaidajis, Georgios; Angelakoglou, Komninos; Gazea, Emmy

    2012-01-01

    To assess ambient air quality at the wider area of a mining-industrial facility in Chalkidiki, Greece, the particulate matter with an aerodynamic diameter of 10 μm (PM(10)) and its content in characteristic elements, i.e., As, Cd, Cu, Fe, Mn, Pb, Zn were monitored for a period of three years (2008-2010). Gravimetric air samplers were employed for the particulate matter sampling at three sampling stations located in the immediate vicinity of the industrial facility and at a neighbouring residential site. Monitoring data indicated that the 3-year median PM(10) concentrations were 23.3 μg/m(3) at the residential site close to the facility and 28.7 μg/m(3) at the site within the facility indicating a minimal influence from the industrial activities to the air quality of the neighbouring residential area. Both annual average and median PM(10) concentration levels were below the indicative European standards, whereas similar spatial and temporal variation was observed for the PM(10) constituents. The average Pb concentrations measured for the three sampling sites were 0.2, 0.146 and 0.174 μg/m(3) respectively, well below the indicative limit of 0.5 μg/m(3). The quantitative and qualitative comparison of PM(10) concentrations and its elemental constituent for the three sampling stations did not indicate any direct influence of the mining-industrial activities to the air quality of the Stratoni residential area.

  9. Evaluating and understanding fish health risks and their consequences in propagated and free-ranging fish populations

    USGS Publications Warehouse

    Moffitt, C.M.; Haukenes, A.H.; Williams, C.J.

    2005-01-01

    Fishery managers and resource conservationists are increasingly interested in understanding the fish health and disease risks of free-ranging fishes and whether propagated fishes or features and practices used at fish culture facilities pose a health risk to free-ranging populations. Disease agents are present in most both captive and all free-ranging fish populations, but the consequences and extent of infections in free-ranging populations are often difficult to measure, control, and understand. Sampling methods, protocols, and assay techniques developed to assess the health of captive populations are not as applicable for assessments of free-ranging fishes. The use of chemicals and therapeutics to control diseases and parasites in propagated fishes likely reduces the risk of introducing specific pathogens into the environment, but control measures may have localized effects on the environment surrounding fish culture facilities. To understand health risks of propagated and free ranging fishes, we must consider fish populations, culture facilities, fish releases, and their interactions within the greater geospatial features of the aquatic environment. ?? 2004 by the American Fisheries Society.

  10. Preliminary Assessment of Health Risks of Potentially Toxic Elements in Settled Dust over Beijing Urban Area

    PubMed Central

    Wan, Dejun; Zhan, Changlin; Yang, Guanglin; Liu, Xingqi; Yang, Jinsong

    2016-01-01

    To examine levels, health risks, sources, and spatial distributions of potentially toxic elements in settled dust over Beijing urban area, 62 samples were collected mostly from residential building outdoor surfaces, and their <63 μm fractions were measured for 12 potentially toxic elements. The results show that V, Cr, Mn, Co, Ni, and Ba in dust are from predominantly natural sources, whereas Cu, Zn, As, Cd, Sb, and Pb mostly originate from anthropogenic sources. Exposure to these elements in dust has significant non-cancer risks to children but insignificant to adults. Cancer risks of Cr, Co, Ni, As, and Cd via inhalation and dermal contact are below the threshold of 10−6–10−4 but As via dust ingestion shows a tolerable risk. The non-cancer risks to children are contributed mainly (75%) by As, Pb, and Sb, and dominantly (92%) via dust ingestion, with relatively higher risks mainly occurring in the eastern and northeastern Beijing urban areas. Although Cd, Zn, and Cu in dust are heavily affected by anthropogenic sources, their health risks are insignificant. Source appointments suggest that coal burning emissions, the dominant source of As, are likely the largest contributors to the health risk, and traffic-related and industrial emissions are also important because they contribute most of the Pb and Sb in dust. PMID:27187427

  11. Active Commuting to School, Weight Status, and Cardiometabolic Risk in Children from Rural Areas: The Cuenca Study

    ERIC Educational Resources Information Center

    Gutiérrez-Zornoza, Myriam; Sánchez-López, Mairena; García-Hermoso, Antonio; González-García, Alberto; Chillón, Palma; Martínez-Vizcaíno, Vicente

    2015-01-01

    Purpose: The aim of this study was to examine (a) whether distance from home to school is a determinant of active commuting to school (ACS), (b) the relationship between distance from home to heavily used facilities (school, green spaces, and sports facilities) and the weight status and cardiometabolic risk categories, and (c) whether ACS has a…

  12. Flood disaster preparedness: a retrospect from Grand Forks, North Dakota.

    PubMed

    Siders, C; Jacobson, R

    1998-01-01

    Natural disasters often come without warning. The clinical, financial, and business risks can be enormous. Grand Forks' (ND) healthcare systems experienced a flooding disaster of unprecedented proportions in April of 1997. Planned and practiced disaster and evacuation procedures can significantly reduce a healthcare facilities' risk to life, health, and safety. This article retrospectively analyzes disaster preparation and the complete evacuation of the facilities' patients.

  13. Asset Management: Roof Maintenance and Facility Energy Retrofits

    DTIC Science & Technology

    2012-03-01

    vapor low emission coatings. Floor finishes completed in ceramic stone tile were the most efficient floor coverings. Fixed insulated fiberglass window...been coined Asset Management which utilizes organizational levels of service, business case analysis, and risk analysis to address urgent...Force have left a number of facility systems such as roofs at risk to disrepair due to a lack of maintenance. Under the principles of asset

  14. The impact of transportation infrastructure on bicycling injuries and crashes: a review of the literature

    PubMed Central

    2009-01-01

    Background Bicycling has the potential to improve fitness, diminish obesity, and reduce noise, air pollution, and greenhouse gases associated with travel. However, bicyclists incur a higher risk of injuries requiring hospitalization than motor vehicle occupants. Therefore, understanding ways of making bicycling safer and increasing rates of bicycling are important to improving population health. There is a growing body of research examining transportation infrastructure and the risk of injury to bicyclists. Methods We reviewed studies of the impact of transportation infrastructure on bicyclist safety. The results were tabulated within two categories of infrastructure, namely that at intersections (e.g. roundabouts, traffic lights) or between intersections on "straightaways" (e.g. bike lanes or paths). To assess safety, studies examining the following outcomes were included: injuries; injury severity; and crashes (collisions and/or falls). Results The literature to date on transportation infrastructure and cyclist safety is limited by the incomplete range of facilities studied and difficulties in controlling for exposure to risk. However, evidence from the 23 papers reviewed (eight that examined intersections and 15 that examined straightaways) suggests that infrastructure influences injury and crash risk. Intersection studies focused mainly on roundabouts. They found that multi-lane roundabouts can significantly increase risk to bicyclists unless a separated cycle track is included in the design. Studies of straightaways grouped facilities into few categories, such that facilities with potentially different risks may have been classified within a single category. Results to date suggest that sidewalks and multi-use trails pose the highest risk, major roads are more hazardous than minor roads, and the presence of bicycle facilities (e.g. on-road bike routes, on-road marked bike lanes, and off-road bike paths) was associated with the lowest risk. Conclusion Evidence is beginning to accumulate that purpose-built bicycle-specific facilities reduce crashes and injuries among cyclists, providing the basis for initial transportation engineering guidelines for cyclist safety. Street lighting, paved surfaces, and low-angled grades are additional factors that appear to improve cyclist safety. Future research examining a greater variety of infrastructure would allow development of more detailed guidelines. PMID:19845962

  15. Life Sciences Centrifuge Facility assessment

    NASA Technical Reports Server (NTRS)

    Benson, Robert H.

    1994-01-01

    This report provides an assessment of the status of the Centrifuge Facility being developed by ARC for flight on the International Space Station Alpha. The assessment includes technical status, schedules, budgets, project management, performance of facility relative to science requirements, and identifies risks and issues that need to be considered in future development activities.

  16. Indicators of Dysphagia in Aged Care Facilities

    ERIC Educational Resources Information Center

    Pu, Dai; Murry, Thomas; Wong, May C. M.; Yiu, Edwin M. L.; Chan, Karen M. K.

    2017-01-01

    Purpose: The current cross-sectional study aimed to investigate risk factors for dysphagia in elderly individuals in aged care facilities. Method: A total of 878 individuals from 42 aged care facilities were recruited for this study. The dependent outcome was speech therapist-determined swallowing function. Independent factors were Eating…

  17. Risk-based decision making for terrorism applications.

    PubMed

    Dillon, Robin L; Liebe, Robert M; Bestafka, Thomas

    2009-03-01

    This article describes the anti-terrorism risk-based decision aid (ARDA), a risk-based decision-making approach for prioritizing anti-terrorism measures. The ARDA model was developed as part of a larger effort to assess investments for protecting U.S. Navy assets at risk and determine whether the most effective anti-terrorism alternatives are being used to reduce the risk to the facilities and war-fighting assets. With ARDA and some support from subject matter experts, we examine thousands of scenarios composed of 15 attack modes against 160 facility types on two installations and hundreds of portfolios of 22 mitigation alternatives. ARDA uses multiattribute utility theory to solve some of the commonly identified challenges in security risk analysis. This article describes the process and documents lessons learned from applying the ARDA model for this application.

  18. The cost risk implementation on design-build project of integrated public spaces child friendly in capital of Jakarta

    NASA Astrophysics Data System (ADS)

    Mardiaman, Mubarok, Abdul

    2017-11-01

    Jakarta area of 662.33 km2 with a population of 10,075,030 inhabitants and green open spaces 9.98%. The Jakarta government built a child-friendly integrated open space as facilities for playing. Providing of facilities was hoped suitable with time, cost, quality, accountability and proper financial governance. Based on the PU ministerial regulation number 19/PRT/M/2015 on the standards and guidelines for procurement the design and construction work on the integrated build and the PU ministerial regulation No. 07/PRT/M/2011 on standards and guidelines for procurement of construction works and consulting services of public works and the ministry of housing. RPTRA development at 123 locations in Jakarta was implemented base on the contract of design and build. The design study was influenced by the cost elements; the main strength (expert), skilled personnel, support personnel, major equipment and support. The construction fee relies on; expert implementation, hardware implementation, preparation work, land, buildings, courtyards, fences, complementary and governance capabilities for human resources in completing the construction activities to minimize the cost risk. Montecarlo simulations was conducted to determine the average unit price, model and analyze systems. In the cost contract, the percentage of design work stipulated 2.5%, build 97.5%. Base on regulation the minister of public work for design work cost 2.72%, build 97.28%. Then, actual cost for design 2.67% and build 97.33%. From the three reference was shown that there are differentiation one another. The acceleration of planning able to make the cost and time more efficient that impact on the implementation margin.

  19. NCDOT : bridge policy

    DOT National Transportation Integrated Search

    1994-11-01

    NCDOTs Bridge Policy establishes controlling design elements for new and reconstructed bridges on the state road system. It includes information to address sidewalks and bicycle facilities on bridges, including minimum handrail heights and sidewal...

  20. Risks to health care workers from nano-enabled medical products.

    PubMed

    Murashov, Vladimir; Howard, John

    2015-01-01

    Nanotechnology is rapidly expanding into the health care industry. However, occupational safety and health risks of nano-enabled medical products have not been thoroughly assessed. This manuscript highlights occupational risk mitigation practices for nano-enabled medical products throughout their life cycle for all major workplace settings including (1) medical research laboratories, (2) pharmaceutical manufacturing facilities, (3) clinical dispensing pharmacies, (4) health care delivery facilities, (5) home health care, (6) health care support, and (7) medical waste management. It further identifies critical research needs for ensuring worker protection in the health care industry.

Top