Sample records for eliminating background interference

  1. Eliminate background interference from latent fingerprints using ultraviolet multispectral imaging

    NASA Astrophysics Data System (ADS)

    Huang, Wei; Xu, Xiaojing; Wang, Guiqiang

    2014-02-01

    Fingerprints are the most important evidence in crime scene. The technology of developing latent fingerprints is one of the hottest research areas in forensic science. Recently, multispectral imaging which has shown great capability in fingerprints development, questioned document detection and trace evidence examination is used in detecting material evidence. This paper studied how to eliminate background interference from non-porous and porous surface latent fingerprints by rotating filter wheel ultraviolet multispectral imaging. The results approved that background interference could be removed clearly from latent fingerprints by using multispectral imaging in ultraviolet bandwidth.

  2. Apparatus for eliminating background interference in fluorescence measurements

    DOEpatents

    Martin, J.C.; Jett, J.H.

    1984-01-06

    The disclosure is directed to an apparatus for eliminating background interference during fluorescence measurements in a multiple laser flow cytometer. A biological particle stained with fluorescent dyes is excited by a laser. A fluorescence detector detects the fluorescence. The particle scatters light and a gate signal is generated and delayed until the biological particle reaches the next laser. The delayed signal turns on this next laser which excites a different stained component of the same biological particle.

  3. Apparatus for eliminating background interference in fluorescence measurements

    DOEpatents

    Martin, John C.; Jett, James H.

    1986-01-01

    The disclosure is directed to an apparatus for eliminating background interference during fluorescence measurements in a multiple laser flow cytometer. A biological particle stained with fluorescent dyes is excited by a laser. A fluorescence detector detects the fluorescence. The particle scatters light and a gate signal is generated and delayed until the biological particle reaches the next laser. The delayed signal turns on this next laser, which excites a different stained component of the same biological particle.

  4. Apparatus for eliminating background interference in fluorescence measurements

    DOEpatents

    Martin, J.C.; Jett, J.H.

    1986-03-04

    The disclosure is directed to an apparatus for eliminating background interference during fluorescence measurements in a multiple laser flow cytometer. A biological particle stained with fluorescent dyes is excited by a laser. A fluorescence detector detects the fluorescence. The particle scatters light and a gate signal is generated and delayed until the biological particle reaches the next laser. The delayed signal turns on this next laser, which excites a different stained component of the same biological particle. 8 figs.

  5. The European experience.

    PubMed

    Bisgaard, N

    2001-06-01

    This article presents an overview of past and current experiences with time division multiple assess-based (Global System for Mobil Communication) mobile telephones in Europe as seen by the European Hearing Instrument Manufacturers Association. Initial fear of widespread interference problems for hearing aid users in general owing to use of a new generation of mobile telephones seems unjustified. The background for the International Electrotechnical Commission 118-13 standard for measuring interference is described. No solution to complete elimination of interference problems resulting from direct contact between hearing aids and mobile telephones has yet been found. Several reports on the subjects are cited, and new work on measurement standards for near-field situations is mentioned.

  6. [An Algorithm to Eliminate Power Frequency Interference in ECG Using Template].

    PubMed

    Shi, Guohua; Li, Jiang; Xu, Yan; Feng, Liang

    2017-01-01

    Researching an algorithm to eliminate power frequency interference in ECG. The algorithm first creates power frequency interference template, then, subtracts the template from the original ECG signals, final y, the algorithm gets the ECG signals without interference. Experiment shows the algorithm can eliminate interference effectively and has none side effect to normal signal. It’s efficient and suitable for practice.

  7. Interference from familiar natural distractors is not eliminated by high perceptual load.

    PubMed

    He, Chunhong; Chen, Antao

    2010-05-01

    A crucial prediction of perceptual load theory is that high perceptual load can eliminate interference from distractors. However, Lavie et al. (Psychol Sci 14:510-515, 2003) found that high perceptual load did not eliminate interference when the distractor was a face. The current experiments examined the interaction between familiarity and perceptual load in modulating interference in a name search task. The data reveal that high perceptual load eliminated the interference effect for unfamiliar distractors that were faces or objects, but did not eliminate the interference for familiar distractors that were faces or objects. Based on these results, we proposed that the processing of familiar and natural stimuli may be immune to the effect of perceptual load.

  8. An improved algorithm of laser spot center detection in strong noise background

    NASA Astrophysics Data System (ADS)

    Zhang, Le; Wang, Qianqian; Cui, Xutai; Zhao, Yu; Peng, Zhong

    2018-01-01

    Laser spot center detection is demanded in many applications. The common algorithms for laser spot center detection such as centroid and Hough transform method have poor anti-interference ability and low detection accuracy in the condition of strong background noise. In this paper, firstly, the median filtering was used to remove the noise while preserving the edge details of the image. Secondly, the binarization of the laser facula image was carried out to extract target image from background. Then the morphological filtering was performed to eliminate the noise points inside and outside the spot. At last, the edge of pretreated facula image was extracted and the laser spot center was obtained by using the circle fitting method. In the foundation of the circle fitting algorithm, the improved algorithm added median filtering, morphological filtering and other processing methods. This method could effectively filter background noise through theoretical analysis and experimental verification, which enhanced the anti-interference ability of laser spot center detection and also improved the detection accuracy.

  9. Determination of 18 kinds of trace impurities in the vanadium battery grade vanadyl sulfate by ICP-OES

    NASA Astrophysics Data System (ADS)

    Yong, Cheng

    2018-03-01

    The method that direct determination of 18 kinds of trace impurities in the vanadium battery grade vanadyl sulfate by inductively coupled plasma atomic emission spectrometry (ICP-OES) was established, and the detection range includes 0.001% ∼ 0.100% of Fe, Cr, Ni, Cu, Mn, Mo, Pb, As, Co, P, Ti, Zn and 0.005% ∼ 0.100% of K, Na, Ca, Mg, Si, Al. That the influence of the matrix effects, spectral interferences and background continuum superposition in the high concentrations of vanadium ions and sulfate coexistence system had been studied, and then the following conclusions were obtained: the sulfate at this concentration had no effect on the determination, but the matrix effects or continuous background superposition which were generated by high concentration of vanadium ions had negative interference on the determination of potassium and sodium, and it produced a positive interference on the determination of the iron and other impurity elements, so that the impacts of high vanadium matrix were eliminated by the matrix matching and combining synchronous background correction measures. Through the spectral interference test, the paper classification summarized the spectral interferences of vanadium matrix and between the impurity elements, and the analytical lines, the background correction regions and working parameters of the spectrometer were all optimized. The technical performance index of the analysis method is that the background equivalent concentration -0.0003%(Na)~0.0004%(Cu), the detection limit of the element is 0.0001%∼ 0.0003%, RSD<10% when the element content is in the range from 0.001% to 0.007%, RSD< 20% even if the element content is in the range from 0.0001% to 0.001% that is beyond the scope of the method of detection, recoveries is 91.0% ∼ 110.0%.

  10. Two techniques for eliminating luminol interference material and flow system configurations for luminol and firefly luciferase systems

    NASA Technical Reports Server (NTRS)

    Thomas, R. R.

    1976-01-01

    Two methods for eliminating luminol interference materials are described. One method eliminates interference from organic material by pre-reacting a sample with dilute hydrogen peroxide. The reaction rate resolution method for eliminating inorganic forms of interference is also described. The combination of the two methods makes the luminol system more specific for bacteria. Flow system designs for both the firefly luciferase and luminol bacteria detection systems are described. The firefly luciferase flow system incorporating nitric acid extraction and optimal dilutions has a functional sensitivity of 3 x 100,000 E. coli/ml. The luminol flow system incorporates the hydrogen peroxide pretreatment and the reaction rate resolution techniques for eliminating interference. The functional sensitivity of the luminol flow system is 1 x 10,000 E. coli/ml.

  11. Interference-free gas-phase thermometry at elevated pressure using hybrid femtosecond/picosecond rotational coherent anti-Stokes Raman scattering.

    PubMed

    Miller, Joseph D; Dedic, Chloe E; Roy, Sukesh; Gord, James R; Meyer, Terrence R

    2012-02-27

    Rotational-level-dependent dephasing rates and nonresonant background can lead to significant uncertainties in coherent anti-Stokes Raman scattering (CARS) thermometry under high-pressure, low-temperature conditions if the gas composition is unknown. Hybrid femtosecond/picosecond rotational CARS is employed to minimize or eliminate the influence of collisions and nonresonant background for accurate, frequency-domain thermometry at elevated pressure. The ability to ignore these interferences and achieve thermometric errors of <5% is demonstrated for N2 and O2 at pressures up to 15 atm. Beyond 15 atm, the effects of collisions cannot be ignored but can be minimized using a short probe delay (~6.5 ps) after Raman excitation, thereby improving thermometric accuracy with a time- and frequency-resolved theoretical model.

  12. A most spectrum-efficient duplexing system: CDD

    NASA Astrophysics Data System (ADS)

    Lee, William C. Y.

    2001-10-01

    The game to play in wireless communications when it comes to increasing spectrum efficiency is to eliminate interference. Currently, all cellular systems use FDD (Frequency Division Duplexing) in an attempt to eliminate the interference from the adjacent cells. Through the use of many technologies only one type of interference remains and that is the adjacent base-tohome mobile interference. TDD (Time Division Duplexing) has not been used for mobile cellular systems, not only because of the adjacent base-to-home mobile interference, but also because of the additional adjacent base-to-home base interference, and adjacent mobile-to-home mobile interference. Therefore, TDD can only be used for small, confined area systems. CDD (Code Division Duplexing) can eliminate all three kinds of interference; the adjacent base-to-home mobile, the adjacent baseto-home base, and the adjacent mobile- to- home in cellular systems. Eliminating each of these interferences makes CDD the most spectrum efficient duplexing system. This talk will elaborate on a set of smart codes, which will make an efficient CDD system a reality.

  13. Single fiber temperature probe configuration using anti-Stokes luminescence from Cr:GdAlO3

    NASA Astrophysics Data System (ADS)

    Eldridge, Jeffrey I.

    2018-06-01

    Single-photon excitation of anti-Stokes-shifted emission from a thermographic phosphor allows operation of a luminescence decay-based single fiber temperature probe with negligible interference from background fiber-generated Raman scattering. While single fiber probe configurations for luminescence-based fiber optic thermometers offer advantages of simple design, compactness, and superior emission light collection efficiency, their effective use has been limited by interference from Raman scattering in the fiber probe and excitation delivery fiber that produces distortion of the luminescence decay that follows the excitation pulse. The near elimination of interference by background fiber-generated Raman scattering was demonstrated by incorporating a Cr-doped GdAlO3 (Cr:GdAlO3) thermographic phosphor as the sensing element at the end of a single fiber luminescence decay-based thermometer and detecting anti-Stokes-shifted luminescence centered at 542 or 593 nm produced by 695 nm excitation. Measurements were performed using both silica (up to 1150 °C) and single-crystal YAG (up to 1200 °C) fiber-based thermometers. Selection of emission detection centered at 542 nm greatly benefited the YAG fiber probe measurements by practically eliminating detection of otherwise significant luminescence from Cr3+ impurities in the YAG fiber. For both the silica and YAG fiber probes, the relative benefit of adopting single-photon excitation of anti-Stokes-shifted luminescence was evaluated by comparison with results obtained by conventional 532 nm excitation of Stokes-shifted luminescence.

  14. Handling of uncertainty due to interference fringe in FT-NIR transmittance spectroscopy - Performance comparison of interference elimination techniques using glucose-water system

    NASA Astrophysics Data System (ADS)

    Beganović, Anel; Beć, Krzysztof B.; Henn, Raphael; Huck, Christian W.

    2018-05-01

    The applicability of two elimination techniques for interferences occurring in measurements with cells of short pathlength using Fourier transform near-infrared (FT-NIR) spectroscopy was evaluated. Due to the growing interest in the field of vibrational spectroscopy in aqueous biological fluids (e.g. glucose in blood), aqueous solutions of D-(+)-glucose were prepared and split into a calibration set and an independent validation set. All samples were measured with two FT-NIR spectrometers at various spectral resolutions. Moving average smoothing (MAS) and fast Fourier transform filter (FFT filter) were applied to the interference affected FT-NIR spectra in order to eliminate the interference pattern. After data pre-treatment, partial least squares regression (PLSR) models using different NIR regions were constructed using untreated (interference affected) spectra and spectra treated with MAS and FFT filter. The prediction of the independent validation set revealed information about the performance of the utilized interference elimination techniques, as well as the different NIR regions. The results showed that the combination band of water at approx. 5200 cm-1 is of great importance since its performance was superior to the one of the so-called first overtone of water at approx. 6800 cm-1. Furthermore, this work demonstrated that MAS and FFT filter are fast and easy-to-use techniques for the elimination of interference fringes in FT-NIR transmittance spectroscopy.

  15. Initial Results from a Search for Lunar Radio Emission from Interactions of >= 10(exp 19) eV Neutrinos and Cosmic Rays

    NASA Technical Reports Server (NTRS)

    Gorham, P. W.; Liewer, K. M.; Naudet, C. J.

    2000-01-01

    Using the NASA Goldstone 70m antenna DSS 14 both singly and in coincidence with the 34 m antenna DSS 13 (21.7 km to the southeast), we have acquired approximately 12 hrs of livetime in a search for predicted pulsed radio emission from extremely-high energy cascades induced by neutrinos or cosmic rays in the lunar regolith. In about 4 hrs of single antenna observations, we reduced our sensitivity to impulsive terrestrial interference to a negligible level by use of a veto afforded by the unique capability of DSS 14. In the 8 hrs of dual-antenna observations, terrestrial interference is eliminated as a background. In both observing modes the thermal noise floor limits the sensitivity. We detected no events above statistical background. We report here initial limits based on these data which begin to constrain several predictions of the flux of EHE neutrinos.

  16. Meaning and the Elimination of Sensory Interference

    ERIC Educational Resources Information Center

    Nelson, Douglas L.; And Others

    1976-01-01

    Research has indicated that interference produced by the sharing of sensory features of paired-associate stimulus words was not eliminated by processing the pairs at the meaning level. These experiments were intended to extend the range of conditions under which the sensory interference effect might persist, and to incorporate the findings within…

  17. Removal of power line interference of space bearing vibration signal based on the morphological filter and blind source separation

    NASA Astrophysics Data System (ADS)

    Dong, Shaojiang; Sun, Dihua; Xu, Xiangyang; Tang, Baoping

    2017-06-01

    Aiming at the problem that it is difficult to extract the feature information from the space bearing vibration signal because of different noise, for example the running trend information, high-frequency noise and especially the existence of lot of power line interference (50Hz) and its octave ingredients of the running space simulated equipment in the ground. This article proposed a combination method to eliminate them. Firstly, the EMD is used to remove the running trend item information of the signal, the running trend that affect the signal processing accuracy is eliminated. Then the morphological filter is used to eliminate high-frequency noise. Finally, the components and characteristics of the power line interference are researched, based on the characteristics of the interference, the revised blind source separation model is used to remove the power line interferences. Through analysis of simulation and practical application, results suggest that the proposed method can effectively eliminate those noise.

  18. Electrochemical sample matrix elimination for trace-level potentiometric detection with polymeric membrane ion-selective electrodes.

    PubMed

    Chumbimuni-Torres, Karin Y; Calvo-Marzal, Percy; Wang, Joseph; Bakker, Eric

    2008-08-01

    Potentiometric sensors are today sufficiently well understood and optimized to reach ultratrace level (subnanomolar) detection limits for numerous ions. In many cases of practical relevance, however, a high electrolyte background hampers the attainable detection limits. A particularly difficult sample matrix for potentiometric detection is seawater, where the high saline concentration forms a major interfering background and reduces the activity of most trace metals by complexation. This paper describes for the first time a hyphenated system for the online electrochemically modulated preconcentration and matrix elimination of trace metals, combined with a downstream potentiometric detection with solid contact polymeric membrane ion-selective microelectrodes. Following the preconcentration at the bismuth-coated electrode, the deposited metals are oxidized and released to a medium favorable to potentiometric detection, in this case calcium nitrate. Matrix interferences arising from the saline sample medium are thus circumvented. This concept is successfully evaluated with cadmium as a model trace element and offers potentiometric detection down to low parts per billion levels in samples containing 0.5 M NaCl background electrolyte.

  19. Electrochemical Sample Matrix Elimination for Trace Level Potentiometric Detection with Polymeric Membrane Ion-Selective Electrodes

    PubMed Central

    Chumbimuni-Torres, Karin Y.; Calvo-Marzal, Percy; Wang, Joseph; Bakker, Eric

    2008-01-01

    Potentiometric sensors are today sufficiently well understood and optimized to reach ultra-trace level (sub-nanomolar) detection limits for numerous ions. In many cases of practical relevance, however, a high electrolyte background hampers the attainable detection limits. A particularly difficult sample matrix for potentiometric detection is seawater, where the high saline concentration forms a major interfering background and reduces the activity of most trace metals by complexation. This paper describes for the first time a hyphenated system for the online electrochemically modulated preconcentration and matrix elimination (EMPM) of trace metals, combined with a downstream potentiometric detection with solid contact polymeric membrane ion-selective microelectrodes. Following the preconcentration at the bismuth coated electrodes, the deposited metals are oxidized and released to a medium favorable to potentiometric detection, in this case calcium nitrate. Matrix interferences arising from the saline sample medium are thus circumvented. This concept is successfully evaluated with cadmium as a model trace element and offers potentiometric detection down to low parts per billion levels in samples containing 0.5 M NaCl background electrolyte. PMID:18570385

  20. Development of a Technique for Separating Raman Scattering Signals from Background Emission with Single-Shot Measurement Potential

    NASA Technical Reports Server (NTRS)

    Hartfield, Roy

    1996-01-01

    Raman scattering is a powerful technique for quantitatively probing high temperature and high speed flows. However, this technique has typically been limited to clean hydrogen flames because of the broadband fluorescence interference which occurs in hydrocarbon flames. Fluorescence can also interfere with the Raman signal in clean hydrogen flames when broadband UV lasers are used as the scattering source. A solution to this problem has been demonstrated. The solution to the fluorescence interference lies in the fact that the vibrational Q-branch Raman signal is highly polarized for 90 deg. signal collection and the fluorescence background is essentially unpolarized. Two basic schemes are available for separating the Raman from the background. One scheme involves using a polarized laser and collecting a signal with both horizontal and vertical laser polarizations separately. The signal with the vertical polarization will contain both the Raman and the fluorescence while the signal with the horizontal polarization will contain only the fluorescence. The second scheme involves polarization discrimination on the collection side of the optical setup. For vertical laser polarization, the scattered Q-branch Raman signal will be vertically polarized; hence the two polarizations can be collected separately and the difference between the two is the Raman signal. This approach has been used for the work found herein and has the advantage of allowing the data to be collected from the same laser shot(s). This makes it possible to collect quantitative Raman data with single shot resolution in conditions where interference cannot otherwise be eliminated.

  1. SERS substrates fabricated using ceramic filters for the detection of bacteria: Eliminating the citrate interference

    NASA Astrophysics Data System (ADS)

    Mosier-Boss, P. A.; Sorensen, K. C.; George, R. D.; Sims, P. C.; O'braztsova, A.

    2017-06-01

    It was found that spectra obtained for bacteria on SERS substrates fabricated by filtering citrate-generated Ag nanoparticles (NPs) onto rigid, ceramic filters exhibited peaks due to citrate as well as the bacteria. In many cases the citrate spectrum overwhelmed that of the bacteria. Given the simplicity of the method to prepare these substrates, means of eliminating this citrate interference were explored. It was found that allowing a mixture of bacteria suspension and citrate-generated Ag NPs to incubate prior to filtering onto the ceramic filter eliminated this interference.

  2. Elimination of interference from water in KBr disk FT-IR spectra of solid biomaterials by chemometrics solved with kinetic modeling.

    PubMed

    Gordon, Sherald H; Harry-O'kuru, Rogers E; Mohamed, Abdellatif A

    2017-11-01

    Infrared analysis of proteins and polysaccharides by the well known KBr disk technique is notoriously frustrated and defeated by absorbed water interference in the important amide and hydroxyl regions of spectra. This interference has too often been overlooked or ignored even when the resulting distortion is critical or even fatal, as in quantitative analyses of protein secondary structure, because the water has been impossible to measure or eliminate. Therefore, a new chemometric method was devised that corrects spectra of materials in KBr disks by mathematically eliminating the water interference. A new concept termed the Beer-Lambert law absorbance ratio (R-matrix) model was augmented with water concentration ratios computed via an exponential decay kinetic model of the water absorption process in KBr, which rendered the otherwise indeterminate system of linear equations determinate and thus possible to solve in a formal analytic manner. Consequently, the heretofore baffling KBr water elimination problem is now solved once and for all. Using the new formal solution, efforts to eliminate water interference from KBr disks in research will be defeated no longer. Resulting spectra of protein were much more accurate than attenuated total reflection (ATR) spectra corrected using the well-accepted Advanced ATR Correction Algorithm. Published by Elsevier B.V.

  3. SERS substrates fabricated using ceramic filters for the detection of bacteria: Eliminating the citrate interference.

    PubMed

    Mosier-Boss, P A; Sorensen, K C; George, R D; Sims, P C; O'braztsova, A

    2017-06-05

    It was found that spectra obtained for bacteria on SERS substrates fabricated by filtering citrate-generated Ag nanoparticles (NPs) onto rigid, ceramic filters exhibited peaks due to citrate as well as the bacteria. In many cases the citrate spectrum overwhelmed that of the bacteria. Given the simplicity of the method to prepare these substrates, means of eliminating this citrate interference were explored. It was found that allowing a mixture of bacteria suspension and citrate-generated Ag NPs to incubate prior to filtering onto the ceramic filter eliminated this interference. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Advanced experimental techniques for transonic wind tunnels - Final lecture

    NASA Technical Reports Server (NTRS)

    Kilgore, Robert A.

    1987-01-01

    A philosophy of experimental techniques is presented, suggesting that in order to be successful, one should like what one does, have the right tools, stick to the job, avoid diversions, work hard, interact with people, be informed, keep it simple, be self sufficient, and strive for perfection. Sources of information, such as bibliographies, newsletters, technical reports, and technical contacts and meetings are recommended. It is pointed out that adaptive-wall test sections eliminate or reduce wall interference effects, and magnetic suspension and balance systems eliminate support-interference effects, while the problem of flow quality remains with all wind tunnels. It is predicted that in the future it will be possible to obtain wind tunnel results at the proper Reynolds number, and the effects of flow unsteadiness, wall interference, and support interference will be eliminated or greatly reduced.

  5. Vanishing dual-task interference after practice: has the bottleneck been eliminated or is it merely latent?

    NASA Technical Reports Server (NTRS)

    Ruthruff, Eric; Johnston, James C.; Van Selst, Mark; Whitsell, Shelly; Remington, Roger

    2003-01-01

    Practice can, in some cases, largely eliminate measured dual-task interference. Does this absence of interference indicate the absence of a processing bottleneck (defined as an inability to carry out certain stages in parallel)? The authors show that a bottleneck need not produce any observable interference, provided that there is no temporal overlap in the demand for bottleneck stages on the 2 tasks. Such a "latent" bottleneck is especially likely after practice, when central stages are short. The authors provide new evidence that a latent bottleneck occurred for a participant who produced no interference in M. Van Selst, E. Ruthruff, and J. C. Johnston (1999). These findings demonstrate that the absence of dual-task interference does not necessarily indicate the absence of a processing bottleneck.

  6. An efficient background modeling approach based on vehicle detection

    NASA Astrophysics Data System (ADS)

    Wang, Jia-yan; Song, Li-mei; Xi, Jiang-tao; Guo, Qing-hua

    2015-10-01

    The existing Gaussian Mixture Model(GMM) which is widely used in vehicle detection suffers inefficiency in detecting foreground image during the model phase, because it needs quite a long time to blend the shadows in the background. In order to overcome this problem, an improved method is proposed in this paper. First of all, each frame is divided into several areas(A, B, C and D), Where area A, B, C and D are decided by the frequency and the scale of the vehicle access. For each area, different new learning rate including weight, mean and variance is applied to accelerate the elimination of shadows. At the same time, the measure of adaptive change for Gaussian distribution is taken to decrease the total number of distributions and save memory space effectively. With this method, different threshold value and different number of Gaussian distribution are adopted for different areas. The results show that the speed of learning and the accuracy of the model using our proposed algorithm surpass the traditional GMM. Probably to the 50th frame, interference with the vehicle has been eliminated basically, and the model number only 35% to 43% of the standard, the processing speed for every frame approximately has a 20% increase than the standard. The proposed algorithm has good performance in terms of elimination of shadow and processing speed for vehicle detection, it can promote the development of intelligent transportation, which is very meaningful to the other Background modeling methods.

  7. Modified zirconium-eriochrome cyanine R determination of fluoride

    USGS Publications Warehouse

    Thatcher, L.L.

    1957-01-01

    The Eriochrome Cyanine R method for determining fluoride in natural water has been modified to provide a single, stable reagent solution, eliminate interference from oxidizing agents, extend the concentration range to 3 p.p.m., and extend the phosphate tolerance. Temperature effect was minimized; sulfate error was eliminated by precipitation. The procedure is sufficiently tolerant to interferences found in natural and polluted waters to permit the elimination of prior distillation for most samples. The method has been applied to 500 samples.

  8. Test techniques: A survey paper on cryogenic tunnels, adaptive wall test sections, and magnetic suspension and balance systems

    NASA Technical Reports Server (NTRS)

    Kilgore, Robert A.; Dress, David A.; Wolf, Stephen W. D.; Britcher, Colin P.

    1989-01-01

    The ability to get good experimental data in wind tunnels is often compromised by things seemingly beyond our control. Inadequate Reynolds number, wall interference, and support interference are three of the major problems in wind tunnel testing. Techniques for solving these problems are available. Cryogenic wind tunnels solve the problem of low Reynolds number. Adaptive wall test sections can go a long way toward eliminating wall interference. A magnetic suspension and balance system (MSBS) completely eliminates support interference. Cryogenic tunnels, adaptive wall test sections, and MSBS are surveyed. A brief historical overview is given and the present state of development and application in each area is described.

  9. Gold in natural water: A method of determination by solvent extraction and electrothermal atomization

    USGS Publications Warehouse

    McHugh, J.B.

    1984-01-01

    A method has been developed using electrothermal atomization to effectively determine the amount of gold in natural water within the nanogram range. The method has four basic steps: (1) evaporating a 1-L sample; (2) putting it in hydrobromic acid-bromine solution; (3) extracting the sample with methyl-isobutyl-ketone; and (4) determining the amount of gold using an atomic absorption spectrophotometer. The limit of detection is 0.001 ??g gold per liter. Results from three studies indicate, respectively, that the method is precise, effective, and free of interference. Specifically, a precision study indicates that the method has a relative standard deviation of 16-18%; a recovery study indicates that the method recovers gold at an average of 93%; and an interference study indicates that the interference effects are eliminated with solvent extraction and background correction techniques. Application of the method to water samples collected from 41 sites throughout the Western United States and Alaska shows a gold concentration range of < 0.001 to 0.036 ??g gold per liter, with an average of 0.005 ??g/L. ?? 1984.

  10. [Pretreatment of Aluminum-Lithium Alloy Sample and Determination of Argentum and Lithium by Spectral Analysis].

    PubMed

    Zhou, Hui; Tan, Qian; Gao, Ya-ling; Sang, Shi-hua; Chen, Wen

    2015-10-01

    Inductively Coupled Plasma Optical Emission Spectrometry (ICP-OES), Flame Atomic Absorption Spectrometry (FAAS) and Visible Spectrometry (VS) was applied for determination of Ag and Li in lithium-aluminium alloy standard sample and test sample, their respective advantages and disadvantages were compared, the excellent selectivity of ICP-OES was confirmed by analyses of certified standard sample. Three different sample digestion methods were compared and discussed in this study. It was found that the better accuracy would be obtained by digesting sample with chloroazotic acid while the content of Li was measured by FAAS, and it was better to digest sample with hydrochloric acid and hydrogen peroxide while determining Ag and Li by ICP-OES simultaneously and determining Ag by FAAS and VS. The interference of co-existing elements and elimination methods was detailedly discussed. Ammonium hydroxide was added to adjust the sample solution into alkalescent and Al, Ti, Zr was precipitated by forming hydroxide precipitation, Mg and Cu was formed complex precipitation with 8-hydroxyquinoline in this condition, then the interference from matrix element to determinate Ag by FAAS was eliminated. In addition, phosphate was used to precipitate Ti to eliminate its interference for determination of Li by FAAS. The same treatment of determination for Ag by FAAS was used to eliminate the interference of matrix element for determination of Ag by VS, the excess of nitrate was added into sample and heated to release Ag+ from silver chloride complex, and the color of 8-hydroxyquinoline was eliminated because of decomposed by heating. The accuracy of analysis result for standard sample was conspicuously improved which confirms the efficient of the method to eliminate interference in this study. The optimal digestion method and eliminate interference method was applied to lithium-aluminium alloy samples. The recovery of samples was from 100.39% to 103.01% by ICP-OES determination for Ag, and from 100.42% to 103.01% by ICP-OES determination for Li. The recovery ranged from 95.91% to 99.98% by FAAS determination for Ag, and ranged from 98.04% to 99.98% for FAAS determination of Li. The recovery was from 98.00% to 101.00 by VS determination for Ag, the analysis results all meet the analysis requirement.

  11. Wind tunnel wall interference investigations in NAE/NRC High Reynolds Number 2D Facility and NASA Langley 0.3m Transonic Cryogenic Tunnel

    NASA Technical Reports Server (NTRS)

    Chan, Y. Y.; Nishimura, Y.; Mineck, R. E.

    1989-01-01

    Results are reported from a NAE/NRC and NASA cooperative program on two-dimensional wind-tunnel wall-interference research, aimed at developing the technology for correcting or eliminating wall interference effects in two-dimensional transonic wind-tunnel investigations. Both NASA Langley and NAE facilities are described, along with a NASA-designed and fabricated airfoil model. It is shown that data from the NAE facility, corrected for wall interference, agree with those obtained from the NASA tunnel, which has adaptive walls; the comparison of surface pressure data shows that the flowfield conditions in which the model is investigated appear to be nearly identical under most conditions. It is concluded that both approaches, posttest correction and an adaptive wall, adequately eliminate the tunnel-wall interference effects.

  12. Quantitative polarized light microscopy using spectral multiplexing interferometry.

    PubMed

    Li, Chengshuai; Zhu, Yizheng

    2015-06-01

    We propose an interferometric spectral multiplexing method for measuring birefringent specimens with simple configuration and high sensitivity. The retardation and orientation of sample birefringence are simultaneously encoded onto two spectral carrier waves, generated interferometrically by a birefringent crystal through polarization mixing. A single interference spectrum hence contains sufficient information for birefringence determination, eliminating the need for mechanical rotation or electrical modulation. The technique is analyzed theoretically and validated experimentally on cellulose film. System simplicity permits the possibility of mitigating system birefringence background. Further analysis demonstrates the technique's exquisite sensitivity as high as ∼20  pm for retardation measurement.

  13. Experiments in a three-dimensional adaptive-wall wind tunnel

    NASA Technical Reports Server (NTRS)

    Schairer, E. T.

    1983-01-01

    Three dimensional adaptive-wall experiments were performed in the Ames Research Center (ARC) 25- by 13-cm indraft wind tunnel. A semispan wing model was mounted to one sidewall of a test section with solid sidewalls, and slotted top and bottom walls. The test section had separate top and bottom plenums which were divided into streamwise and cross-stream compartments. An iterative procedure was demonstrated for measuring wall interference and for adjusting the plenum compartment pressures to eliminate such interference. The experiments were conducted at a freestream Mach number of 0.60 and model angles of attack between 0 and 6 deg. Although in all the experiments wall interference was reduced after the plenum pressures were adjusted, interference could not be completely eliminated.

  14. 47 CFR 18.115 - Elimination and investigation of harmful interference.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... interference. 18.115 Section 18.115 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL INDUSTRIAL... by the Commission's Engineer in Charge (EIC) that operation of such equipment is endangering the... causing harmful interference, the operator or manufacturer shall arrange for an engineer skilled in...

  15. 47 CFR 18.115 - Elimination and investigation of harmful interference.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... interference. 18.115 Section 18.115 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL INDUSTRIAL... by the Commission's Engineer in Charge (EIC) that operation of such equipment is endangering the... causing harmful interference, the operator or manufacturer shall arrange for an engineer skilled in...

  16. Monochloramine-sensitive amperometric microelectrode: optimization of gold, platinum, and carbon fiber sensing materials for removal of dissolved oxygen interference

    EPA Science Inventory

    Amperometric monochloramine detection using newly fabricated gold, platinum, and carbon-fiber microsensors was investigated to optimize sensor operation and eliminate oxygen interference. Gold and platinum microsensors exhibited no oxygen interference during monochloramine measu...

  17. Control techniques to improve Space Shuttle solid rocket booster separation

    NASA Technical Reports Server (NTRS)

    Tomlin, D. D.

    1983-01-01

    The present Space Shuttle's control system does not prevent the Orbiter's main engines from being in gimbal positions that are adverse to solid rocket booster separation. By eliminating the attitude error and attitude rate feedback just prior to solid rocket booster separation, the detrimental effects of the Orbiter's main engines can be reduced. In addition, if angular acceleration feedback is applied, the gimbal torques produced by the Orbiter's engines can reduce the detrimental effects of the aerodynamic torques. This paper develops these control techniques and compares the separation capability of the developed control systems. Currently with the worst case initial conditions and each Shuttle system dispersion aligned in the worst direction (which is more conservative than will be experienced in flight), the solid rocket booster has an interference with the Shuttle's external tank of 30 in. Elimination of the attitude error and attitude rate feedback reduces that interference to 19 in. Substitution of angular acceleration feedback reduces the interference to 6 in. The two latter interferences can be eliminated by atess conservative analysis techniques, that is, by using a root sum square of the system dispersions.

  18. Differential optical absorption spectrometer for measurement of tropospheric pollutants

    NASA Astrophysics Data System (ADS)

    Evangelisti, F.; Baroncelli, A.; Bonasoni, P.; Giovanelli, G.; Ravegnani, F.

    1995-05-01

    Our institute has recently developed a differential optical absorption spectrometry system called the gas analyzer spectrometer correlating optical absorption differences (GASCOAD), which features as a detector a linear image sensor that uses an artificial light source for long-path tropospheric-pollution monitoring. The GASCOAD, its method of eliminating interference from background sky light, and subsequent spectral analysis are reported and discussed. The spectrometer was used from 7 to 22 February 1993 in Milan, a heavily polluted metropolitan area, to measure the concentrations of SO2, NO2, O3, and HNO2 averaged over a 1.7-km horizontal light path. The findings are reported and briefly discussed.

  19. Small Business Innovation Research (SBIR) Program, FY 1992. Program Solicitation 92.1, Closing Date: 10 January 1992

    DTIC Science & Technology

    1991-01-01

    12, 17, 53, 59, 63, 65, 67, 93 instrumentation ............................................................... 48, 59, 74, 79 interference ...capable of containing phase holograms (phase gratings) which are induced (written) by incident optical interference patterns (spatially varying incident...automation must work in the presence of clutter, false returns, and other interference and must eliminate as much of the interference as possible. The MSS

  20. Negative interference by rheumatoid factor in alpha-fetoprotein chemiluminescent microparticle immunoassay.

    PubMed

    Wang, Hui; Bi, Xiaohui; Xu, Lei; Li, Yirong

    2017-01-01

    Background Rheumatoid factor causes positive interference in multiple immunoassays. Recently, negative interference has also been found in immunoassays in the presence of rheumatoid factor. The chemiluminescent microparticle immunoassay is widely used to determine serum alpha-fetoprotein. However, it is not clear whether the presence of rheumatoid factor in the serum causes interference in the chemiluminescent microparticle immunoassay of alpha-fetoprotein. Methods Serum alpha-fetoprotein was determined using the ARCHITECT alpha-fetoprotein assay. The estimation of alpha-fetoprotein recovery was carried out in samples prepared by diluting high-concentration alpha-fetoprotein serum with rheumatoid factor-positive or rheumatoid factor-negative serum. Paramagnetic microparticles coated with hepatitis B surface antigen-anti-HBs complexes were used to remove rheumatoid factor from the serum. Results The average recovery of alpha-fetoprotein was 88.4% and 93.8% in the rheumatoid factor-positive and rheumatoid factor-negative serum samples, respectively. The recovery of alpha-fetoprotein was significantly lower in the rheumatoid factor-positive serum samples than in the rheumatoid factor-negative serum samples. In two of five rheumatoid factor-positive samples, a large difference was found (9.8%) between the average alpha-fetoprotein recoveries in the serially diluted and initial recoveries. Fourteen rheumatoid factor-positive serum samples were pretreated with hepatitis B surface antigen-anti-HBs complex-coated paramagnetic microparticles. The alpha-fetoprotein concentrations measured in the pretreated samples increased significantly. Conclusions It was concluded that the alpha-fetoprotein chemiluminescent microparticle immunoassay is susceptible to interference by rheumatoid factor, leading to significantly lower results. Eliminating the incidence of negative interference from rheumatoid factor should be an important goal for immunoassay providers. In the meantime, laboratorians must remain alert to the negative interference by rheumatoid factor, and in some cases, pretreat rheumatoid factor-positive samples with blocking or absorbing reagents.

  1. Novel method of detecting movement of the interference fringes using one-dimensional PSD.

    PubMed

    Wang, Qi; Xia, Ji; Liu, Xu; Zhao, Yong

    2015-06-02

    In this paper, a method of using a one-dimensional position-sensitive detector (PSD) by replacing charge-coupled device (CCD) to measure the movement of the interference fringes is presented first, and its feasibility is demonstrated through an experimental setup based on the principle of centroid detection. Firstly, the centroid position of the interference fringes in a fiber Mach-Zehnder (M-Z) interferometer is solved in theory, showing it has a higher resolution and sensitivity. According to the physical characteristics and principles of PSD, a simulation of the interference fringe's phase difference in fiber M-Z interferometers and PSD output is carried out. Comparing the simulation results with the relationship between phase differences and centroid positions in fiber M-Z interferometers, the conclusion that the output of interference fringes by PSD is still the centroid position is obtained. Based on massive measurements, the best resolution of the system is achieved with 5.15, 625 μm. Finally, the detection system is evaluated through setup error analysis and an ultra-narrow-band filter structure. The filter structure is configured with a one-dimensional photonic crystal containing positive and negative refraction material, which can eliminate background light in the PSD detection experiment. This detection system has a simple structure, good stability, high precision and easily performs remote measurements, which makes it potentially useful in material small deformation tests, refractivity measurements of optical media and optical wave front detection.

  2. Elimination of the acetaminophen interference in an implantable glucose sensor.

    PubMed

    Zhang, Y; Hu, Y; Wilson, G S; Moatti-Sirat, D; Poitout, V; Reach, G

    1994-04-01

    Acetaminophen has been one of the most serious electrochemical interferences to oxidase-based amperometric biosensors that measure H2O2. A study was carried out to investigate various polymer materials for their selectivity as the sensor inner membrane. A composite membrane of cellulose acetate and Nafion was found to eliminate acetaminophen and other electrochemical interferences effectively while at the same time maintaining reasonable diffusivity for hydrogen peroxide. The excellent in vivo performance of the sensor was attributed not only to significantly reduced steady-state sensitivity to acetaminophen but also to very slow acetaminophen response. These features, combined with rapid acetaminophen clearance pharmacokinetics, led to the decreased response as demonstrated in the rat.

  3. Importance of resonance interference effects in multigroup self-shielding calculation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stachowski, R.E.; Protsik, R.

    1995-12-31

    The impact of the resonance interference method (RIF) on multigroup neutron cross sections is significant for major isotopes in the fuel, indicating the importance of resonance interference in the computation of gadolinia burnout and plutonium buildup. The self-shielding factor method with the RIF method effectively eliminates shortcomings in multigroup resonance calculations.

  4. Elimination of interference from water in KBr disk FT-IR spectra of solid biomaterials by chemometrics solved with kinetic modeling

    USDA-ARS?s Scientific Manuscript database

    Infrared analysis of proteins and polysaccharides by the well known KBr disk technique is notoriously frustrated and defeated by absorbed water interference in the important amide and hydroxyl regions of spectra. This interference has too often been overlooked or ignored even when the resulting dist...

  5. Effects of Practice on Task Architecture: Combined Evidence from Interference Experiments and Random-Walk Models of Decision Making

    ERIC Educational Resources Information Center

    Kamienkowski, Juan E.; Pashler, Harold; Dehaene, Stanislas; Sigman, Mariano

    2011-01-01

    Does extensive practice reduce or eliminate central interference in dual-task processing? We explored the reorganization of task architecture with practice by combining interference analysis (delays in dual-task experiment) and random-walk models of decision making (measuring the decision and non-decision contributions to RT). The main delay…

  6. Concept and properties of an infrared hybrid single-beam spectrum and its application to eliminate solvent bands and other background interferences.

    PubMed

    Chen, Yujing; Wang, Hai-Shui; Morisawa, Yusuke; Ozaki, Yukihiro

    2014-02-01

    For infrared (IR) spectral measurements, if a quality single-beam background spectrum with desired intensity could be obtained, the contributions from solvent and other background components could be completely suppressed and their bands would not appear in a final transmittance/absorbance spectrum. In order to achieve this ideal but difficult goal, the concept of hybrid single-beam spectrum is introduced in this paper. The hybrid single-beam spectrum (φ h) is defined as a mixture of two single-beam spectra (φ b1 and φ b2) of the same sample but with different pathlengths (b1 and b2), namely, φ h = αφ b1+(1-α)φ b2, where α (0 ≤ α ≤ 1) is the component factor. The properties of the hybrid spectrum have been investigated. Under conditions of b2 > b1 ≥ 0.7 b2 and A max ≤ 0.60 (Amax is the maximum absorbance of b2 sample in the spectral range of interest), all the synthesized hybrid spectra are free from significant distortion regardless of the component factor. Therefore, the hybrid single-beam spectrum with desired intensity can be easily obtained simply by choosing an appropriate component factor. The proposed methodology has been demonstrated experimentally by the complete removal of the interference from the atmospheric water vapor and solvent. © 2013 Elsevier B.V. All rights reserved.

  7. Live-Cell Pyrophosphate Imaging by in Situ Hot-Spot Generation.

    PubMed

    Li, Mingmin; Li, Jin; Di, Huixia; Liu, Huiqiao; Liu, Dingbin

    2017-03-21

    Controlling the electromagnetic hot-spot generation is essential for surface-enhanced Raman scattering (SERS) assays. Current hot-spot-based SERS assays have been extensively studied in solutions or on substrates. However, probing biospecies by controlling the hot-spot assembly in living systems has not been demonstrated thus far. Herein, we report a background-free SERS probe for imaging pyrophosphate (PPi), a biochemically significant anion, in living cells. Intracellular PPi is able to induce the nanoparticle dimerization, thus creating an intense electromagnetic hot spot and dramatically enhancing the signal of the Raman reporters residing in the hot spot. More impressively, the reporter we used in this study provides a strong and sharp single peak in the cellular Raman-silent region (1800-2800 cm -1 ), thus eliminating the possible background interference. This strategy could be readily extended to detect other biomarkers by only replacing the recognition ligands.

  8. Public access defibrillation: Suppression of 16.7 Hz interference generated by the power supply of the railway systems

    PubMed Central

    Christov, Ivaylo I; Iliev, Georgi L

    2005-01-01

    Background A specific problem using the public access defibrillators (PADs) arises at the railway stations. Some countries as Germany, Austria, Switzerland, Norway and Sweden are using AC railroad net power-supply system with rated 16.7 Hz frequency modulated from 15.69 Hz to 17.36 Hz. The power supply frequency contaminates the electrocardiogram (ECG). It is difficult to be suppressed or eliminated due to the fact that it considerably overlaps the frequency spectra of the ECG. The interference impedes the automated decision of the PADs whether a patient should be (or should not be) shocked. The aim of this study is the suppression of the 16.7 Hz interference generated by the power supply of the railway systems. Methods Software solution using adaptive filtering method was proposed for 16.7 Hz interference suppression. The optimal performance of the filter is achieved, embedding a reference channel in the PADs to record the interference. The method was tested with ECGs from AHA database. Results The method was tested with patients of normal sinus rhythms, symptoms of tachycardia and ventricular fibrillation. Simulated interference with frequency modulation from 15.69 Hz to 17.36 Hz changing at a rate of 2% per second was added to the ECGs, and then processed by the suggested adaptive filtering. The method totally suppresses the noise with no visible distortions of the original signals. Conclusion The proposed adaptive filter for noise suppression generated by the power supply of the railway systems has a simple structure requiring a low level of computational resources, but a good reference signal as well. PMID:15766390

  9. Integrated Raman spectroscopy and trimodal wide-field imaging techniques for real-time in vivo tissue Raman measurements at endoscopy.

    PubMed

    Huang, Zhiwei; Teh, Seng Khoon; Zheng, Wei; Mo, Jianhua; Lin, Kan; Shao, Xiaozhuo; Ho, Khek Yu; Teh, Ming; Yeoh, Khay Guan

    2009-03-15

    We report an integrated Raman spectroscopy and trimodal (white-light reflectance, autofluorescence, and narrow-band) imaging techniques for real-time in vivo tissue Raman measurements at endoscopy. A special 1.8 mm endoscopic Raman probe with filtering modules is developed, permitting effective elimination of interference of fluorescence background and silica Raman in fibers while maximizing tissue Raman collections. We demonstrate that high-quality in vivo Raman spectra of upper gastrointestinal tract can be acquired within 1 s or subseconds under the guidance of wide-field endoscopic imaging modalities, greatly facilitating the adoption of Raman spectroscopy into clinical research and practice during routine endoscopic inspections.

  10. Intersystem Interference Reduction for Overlaid HAPS-Terrestrial CDMA System

    NASA Astrophysics Data System (ADS)

    Huang, Jeng-Ji; Wang, Wei-Ting; Li, Mingfu; Shiung, David; Ferng, Huei-Wen

    In this letter, we propose that directional antennas, combined with power management, be incorporated to reduce intersystem interference in a shared band overlaid high altitude platform station (HAPS)-terrestrial code division multiple access (CDMA) system. To eliminate the HAPS to terrestrial interference, the HAPS is accessed only via directional antennas under the proposed scheme. By doing so, the uplink power to the HAPS can accordingly be increased, so that the terrestrial to HAPS interference is also effectively suppressed.

  11. Interfering lipoproteins in magnetic field-assisted agglutination of superparamagnetic particles immunoassay.

    PubMed

    Cauet, Gilles; Daynès, Aurélien; Temurok, Nevzat

    2016-04-01

    The technology of magnetic field-assisted immuno-agglutination of superparamagnetic particles allows sensitive detection of biomarkers in whole blood. However, we observed non-specific agglutination (NSA), due to interfering plasma proteins, that negatively affects C-reactive protein immunoassay. The objective of the study was to identify the plasma proteins involved and to eliminate these interferences. Plasma was fractionated by size exclusion HPLC and each fraction was tested for non-specific agglutination. In addition, plasma proteins bound to magnetic particles were analyzed by SDS-gel electrophoresis and identified by mass spectrometry. We found that NSA was due to the binding of some lipoproteins to the particles. NSA was observed in the presence of purified LDL and VLDL but not HDL. NSA was mediated by the binding of ApoB100 to magnetic particles through its heparin binding sites. These interferences could be eliminated by addition of heparin or other polyanions like dextran sulfate to the assay buffer. NSA results from the binding of some plasma lipoproteins to magnetic particles. The use of a polyanion to eliminate these interferences allows the formulation of a stable reagent.

  12. New Possibilities for the Accurate in Situ Determination of Chalcophile and Siderophile Trace Elements by Laser Ablation Collision and Reaction Cell ICP-MS

    NASA Astrophysics Data System (ADS)

    Mason, P. R.

    2004-05-01

    Our knowledge of how chalcophile and siderophile elements partition in minerals is limited, mainly due to the lack of suitable techniques for their accurate in situ determination. Host minerals (e.g. sulphides) are typically of small size (<30 μ m) and highly heterogeneous in composition, requiring analysis of high spatial resolution. Concentrations of chalcophile elements in silicates and oxides are low (sub μ gg-1) and thus challenging to measure. Laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS), offering high sensitivity and good spatial resolution (10-100 μ m) is thus highly suited for this purpose. Unfortunately, the widespread use of this technique has been limited by enhanced problems specific to chalcophile and siderophile elements. These include inaccuracy due to the presence of spectral interferences, elemental fractionation during ablation/ionization and the lack of suitable calibration standards. Polyatomic spectral interferences, present either as a background component (e.g. O2+, ArAr+) or based around the recombination of matrix elements with argon (e.g. ArS+, ArNi+) hinder accurate analysis. These depend upon the relative concentrations of major matrix components and trace elements to be measured and are significant in many relevant minerals (e.g. sulphides). The use of a collision and reaction cells in ICP-MS is a new method for selective interference attenuation, significantly improving detection limits for elements such as Fe, S and Se by between 1 and 4 orders of magnitude. ArNi+ and ArCu+ interferences in sulphides can be attenuated by at least an order of magnitude leading to improved accuracy for the measurement of the Platinum Group elements Rh and Ru. Sulphur isotopes can be measured interference-free at m/z=32 and 34 by eliminating background O2+. These improvements open up new possibilities for the use of LA-ICP-MS in trace element and isotopic studies at the lowest concentration levels or where sample preparation creates additional problems (e.g. NiS fire assay beads). I will give examples of applications for this technique in the study of ore minerals, meteorites and precipitates from hydrothermal vents.

  13. RNA Interference Therapies for an HIV-1 Functional Cure.

    PubMed

    Scarborough, Robert J; Gatignol, Anne

    2017-12-27

    HIV-1 drug therapies can prevent disease progression but cannot eliminate HIV-1 viruses from an infected individual. While there is hope that elimination of HIV-1 can be achieved, several approaches to reach a functional cure (control of HIV-1 replication in the absence of drug therapy) are also under investigation. One of these approaches is the transplant of HIV-1 resistant cells expressing anti-HIV-1 RNAs, proteins or peptides. Small RNAs that use RNA interference pathways to target HIV-1 replication have emerged as competitive candidates for cell transplant therapy and have been included in all gene combinations that have so far entered clinical trials. Here, we review RNA interference pathways in mammalian cells and the design of therapeutic small RNAs that use these pathways to target pathogenic RNA sequences. Studies that have been performed to identify anti-HIV-1 RNA interference therapeutics are also reviewed and perspectives on their use in combination gene therapy to functionally cure HIV-1 infection are provided.

  14. Classification of normal and malignant human gastric mucosa tissue with confocal Raman microspectroscopy and wavelet analysis

    NASA Astrophysics Data System (ADS)

    Hu, Yaogai; Shen, Aiguo; Jiang, Tao; Ai, Yong; Hu, Jiming

    2008-02-01

    Thirty-two samples from the human gastric mucosa tissue, including 13 normal and 19 malignant tissue samples were measured by confocal Raman microspectroscopy. The low signal-to-background ratio spectra from human gastric mucosa tissues were obtained by this technique without any sample preparation. Raman spectral interferences include a broad featureless sloping background due to fluorescence and noise. They mask most Raman spectral feature and lead to problems with precision and quantitation of the original spectral information. A preprocessed algorithm based on wavelet analysis was used to reduce noise and eliminate background/baseline of Raman spectra. Comparing preprocessed spectra of malignant gastric mucosa tissues with those of counterpart normal ones, there were obvious spectral changes, including intensity increase at ˜1156 cm -1 and intensity decrease at ˜1587 cm -1. The quantitative criterion based upon the intensity ratio of the ˜1156 and ˜1587 cm -1 was extracted for classification of the normal and malignant gastric mucosa tissue samples. This could result in a new diagnostic method, which would assist the early diagnosis of gastric cancer.

  15. Noise reduction in digital holography based on a filtering algorithm

    NASA Astrophysics Data System (ADS)

    Zhang, Wenhui; Cao, Liangcai; Zhang, Hua; Jin, Guofan; Brady, David

    2018-02-01

    Holography is a tool to record the object wavefront by interference. Complex amplitude of the object wave is coded into a two dimensional hologram. Unfortunately, the conjugate wave and background wave would also appear at the object plane during reconstruction, as noise, which blurs the reconstructed object. From the perspective of wave, we propose a filtering algorithm to get a noise-reduced reconstruction. Due to the fact that the hologram is a kind of amplitude grating, three waves would appear when reconstruction, which are object wave, conjugate wave and background wave. The background is easy to eliminate by frequency domain filtering. The object wave and conjugate wave are signals to be dealt with. These two waves, as a whole, propagate in the space. However, when detected at the original object plane, the object wave would diffract into a sparse pattern while the conjugate wave would diffract into a diffused pattern forming the noise. Hence, the noise can be reduced based on these difference with a filtering algorithm. Both amplitude and phase distributions are truthfully retrieved in our simulation and experimental demonstration.

  16. ARSENIC DETERMINATION BY THE SILVER DIETHYLDITHIOCARBAMATE METHOD AND THE ELIMINATION OF METAL ION INTERFERENCE

    EPA Science Inventory

    The interference of metals with the determination of arsenic by the silver diethyldithiocarbamate (SDDC) Method was investigated. Low recoveries of arsenic are obtained when cobalt, chromium, molybdenum, nitrate, nickel or phosphate are at concentrations of 7 mg/l or above (indiv...

  17. Development of gas fire detection system using tunable diode laser absorption spectroscopy

    NASA Astrophysics Data System (ADS)

    Jiang, Y. L.; Li, G.; Yang, T.; Wang, J. J.

    2017-01-01

    The conventional fire detection methods mainly produce an alarm through detecting the changes in smoke concentration, flame radiation, heat and other physical parameters in the environment, but are unable to provide an early warning of a fire emergency. We have designed a gas fire detection system with a high detection sensitivity and high selectivity using the tunable semiconductor diode laser as a light source and combining wavelength modulation and harmonic detection technology. This system can invert the second harmonic signal obtained to obtain the concentration of carbon monoxide gas (a fire characteristic gas) so as to provide an early warning of fire. We reduce the system offset noise and the background noise generated due to the laser interference by deducting the system background spectrum lines from the second harmonic signal. This can also eliminate the interference of other gas spectral lines to a large extent. We detected the concentration of the carbon monoxide gas generated in smoldering sandalwood fire and open beech wood fire with the homemade fire simulator, and tested the lowest detectable limit of system. The test results show that the lowest detectable limit can reach 5×10-6 the system can maintain stable operation for a long period of time and can automatically trigger a water mist fire extinguishing system, which can fully meet the needs of early fire warning.

  18. A Novel Complex-Coefficient In-Band Interference Suppression Algorithm for Cognitive Ultra-Wide Band Wireless Sensors Networks.

    PubMed

    Xiong, Hailiang; Zhang, Wensheng; Xu, Hongji; Du, Zhengfeng; Tang, Huaibin; Li, Jing

    2017-05-25

    With the rapid development of wireless communication systems and electronic techniques, the limited frequency spectrum resources are shared with various wireless devices, leading to a crowded and challenging coexistence circumstance. Cognitive radio (CR) and ultra-wide band (UWB), as sophisticated wireless techniques, have been considered as significant solutions to solve the harmonious coexistence issues. UWB wireless sensors can share the spectrum with primary user (PU) systems without harmful interference. The in-band interference of UWB systems should be considered because such interference can severely affect the transmissions of UWB wireless systems. In order to solve the in-band interference issues for UWB wireless sensor networks (WSN), a novel in-band narrow band interferences (NBIs) elimination scheme is proposed in this paper. The proposed narrow band interferences suppression scheme is based on a novel complex-coefficient adaptive notch filter unit with a single constrained zero-pole pair. Moreover, in order to reduce the computation complexity of the proposed scheme, an adaptive complex-coefficient iterative method based on two-order Taylor series is designed. To cope with multiple narrow band interferences, a linear cascaded high order adaptive filter and a cyclic cascaded high order matrix adaptive filter (CCHOMAF) interference suppression algorithm based on the basic adaptive notch filter unit are also presented. The theoretical analysis and numerical simulation results indicate that the proposed CCHOMAF algorithm can achieve better performance in terms of average bit error rate for UWB WSNs. The proposed in-band NBIs elimination scheme can significantly improve the reception performance of low-cost and low-power UWB wireless systems.

  19. A Novel Complex-Coefficient In-Band Interference Suppression Algorithm for Cognitive Ultra-Wide Band Wireless Sensors Networks

    PubMed Central

    Xiong, Hailiang; Zhang, Wensheng; Xu, Hongji; Du, Zhengfeng; Tang, Huaibin; Li, Jing

    2017-01-01

    With the rapid development of wireless communication systems and electronic techniques, the limited frequency spectrum resources are shared with various wireless devices, leading to a crowded and challenging coexistence circumstance. Cognitive radio (CR) and ultra-wide band (UWB), as sophisticated wireless techniques, have been considered as significant solutions to solve the harmonious coexistence issues. UWB wireless sensors can share the spectrum with primary user (PU) systems without harmful interference. The in-band interference of UWB systems should be considered because such interference can severely affect the transmissions of UWB wireless systems. In order to solve the in-band interference issues for UWB wireless sensor networks (WSN), a novel in-band narrow band interferences (NBIs) elimination scheme is proposed in this paper. The proposed narrow band interferences suppression scheme is based on a novel complex-coefficient adaptive notch filter unit with a single constrained zero-pole pair. Moreover, in order to reduce the computation complexity of the proposed scheme, an adaptive complex-coefficient iterative method based on two-order Taylor series is designed. To cope with multiple narrow band interferences, a linear cascaded high order adaptive filter and a cyclic cascaded high order matrix adaptive filter (CCHOMAF) interference suppression algorithm based on the basic adaptive notch filter unit are also presented. The theoretical analysis and numerical simulation results indicate that the proposed CCHOMAF algorithm can achieve better performance in terms of average bit error rate for UWB WSNs. The proposed in-band NBIs elimination scheme can significantly improve the reception performance of low-cost and low-power UWB wireless systems. PMID:28587085

  20. The Ranschburg Effect: Tests of the Guessing-Bias and Proactive Interference Hypotheses

    ERIC Educational Resources Information Center

    Walsh, Michael F.; Schwartz, Marian

    1977-01-01

    The guessing-bias and proactive interference hypotheses of the Ranschburg Effect were investigated by giving three groups different instructions as to guessing during recall. Results failed to support the prediction that the effect should be reduced or eliminated on shift trials. Neither hypothesis received significant support. (CHK)

  1. A flow system for the spectrophotometric determination of lead in different types of waters using ion-exchange for pre-concentration and elimination of interferences.

    PubMed

    Mesquita, Raquel B R; Fernandes, Sílvia M V; Rangel, António O S S

    2004-02-06

    A flow system for the spectrophotometric determination of lead in natural and waste waters is proposed. The determination is based on the colorimetric reaction between malachite green and iodide, followed by the formation of a ternary complex between those reagents and lead cations. The developed flow system includes a lead pre-concentration step in a column packed with a cationic resin (Chelex 100) operating in a sequential injection mode. To improve the mixture of sample and reagents, a flow injection approach was adopted for the colorimetric determination. This way a hybrid flow system, involving both sequential and flow injection concepts was designed. Another feature of the proposed system is the efficient elimination of major interferent species, such as cadmium and copper. The elimination of cadmium interference is obtained by complexing Cd(2+) with chloride and retaining the formed negatively charged complexes in an anionic resin, AG1 X-8. As for copper, with the presence of both ionic resins as well as the conditions for cadmium elimination, it no longer acts as an interferent. Different ranges of lead concentration (50-300 and 300-1000mugl(-1)) can be determined with minor changes in the controlling software, useful for application to both natural and waste waters. Therefore, a detection limit of 25mugl(-1) was achieved. Repeatability was evaluated from 10 consecutive determinations being the results better than 4%. The recoveries of lead spikes added to the samples ranged from 93 to 102%. The sampling frequency was 17 and 24 determinations per hour, for 50-300 and 300-1000mugl(-1) ranges, respectively.

  2. Elimination of interference component in Wigner-Ville distribution for the signal with 1/f spectral characteristic.

    PubMed

    Chan, H L; Lin, J L; Huang, H H; Wu, C P

    1997-09-01

    A new technique for interference-term suppression in Wigner-Ville distribution (WVD) is proposed for the signal with 1/f spectrum shape. The spectral characteristic of the signal is altered by f alpha filtering before time-frequency analysis and compensated after analysis. With the utilization of the proposed technique in smoothed pseudo Wigner-Ville distribution, an excellent suppression of interference component can be achieved.

  3. Effect of residual ascorbate on determination of nitrite in commercial cured meat products.

    PubMed

    Fox, J B; Doerr, R C; Gates, R

    1984-01-01

    Residual ascorbate in cured meat slurries results in different amounts of pigment being produced from different Griess reagent combinations. The phenomenon was used to study residual ascorbate in commercial cured meat products which had a variety of textures, acidities, moisture and meat content, fat, homogeneity, initial nitrite, and processing conditions. Diluting and heating the samples according to the AOAC procedure did not completely eliminate the ascorbate interference, but making the sample alkaline did. Determining nitrite separately in supernate and precipitate from the first dilution showed the effect of heating to be the elimination of interferences and solubilization or extraction of nitrite from the precipitate.

  4. [Determination of paraquat and diquat in drinking water and environmental water by high performance liquid chromatography coupled with on-line clean-up and solid phase extraction].

    PubMed

    Chen, Jing; Liu, Zhaojin; An, Baochao; Lu, Yan; Xu, Qun

    2012-10-01

    An on-line solid phase extraction (SPE) system was used to eliminate the interferences sufficiently and fulfill the simple and sensitive determination of diquat and paraquat in tap and pond water. This on-line SPE system used two SPE cartridges. One was an Acclaim Mixed-Mode WAX-1 cartridge for the elimination of anionic interferences; the other one was an Acclaim Mixed-Mode WCX-1 cartridge for the enrichment of diquat and paraquat and the elimination of co-enriched cationic interferences. The baseline separation of diquat and paraquat was achieved on an Acclaim Trinity P1 column. A dual-gradient high performance liquid chromatographic (HPLC) system provided an efficient platform to fulfill the on-line SPE and separation, and the system operated under automatic control of chromatography data system software. The complete analysis only required 16 min, and the detection limits of the method were 0.12 microg/L for diquat and 0.10 microg/L for paraquat. The method is simple, rapid and sensitive, and can be applied to the determination of diquat and paraquat in drinking water and environmental water.

  5. Time-resolved determination of Fe(II) ions using cysteine-bridged Mn-doped ZnS quantum dots as a phosphorimetric probe.

    PubMed

    Jing, Wenjie; Lu, Yuexiang; Wang, Feiyang; He, Liuying; Sun, Jingwei; Liu, Yueying

    2018-05-12

    A time-resolved phosphorescence (TRP) is applied to the highly sensitive determination of Fe(II) ions. The method is based on the use of a phosphorescent probe consisting of cysteine-bridged Mn-doped ZnS quantum dots (Mn/ZnS QDs). The presence of cysteine enhances the phosphorescence of the QDs and also increases the efficiency of quenching caused by Fe(II) ions. This results in strongly improved selectivity for Fe(II). The linear response is obtained in the concentration range of 50-1000 nM with a 19 nM detection limit. Phosphorescence is recorded at excitation/emission peaks of 301/602 nm. The interference of short-lived fluorescent and scattering background from the biological fluids is eliminated by using the TRP mode with a delay time of 200 μs. The determination of Fe(II) in human serum samples spiked at a 150 nM level gave a 92.4% recovery when using the TRP mode, but only 52.4% when using steady-state phosphorescence. This demonstrates that this probe along with TRP detection enables highly sensitive and accurate determination of Fe(II) in serum. Graphical abstract Schematic of a novel phosphorescent method for the detection of Fe 2+ ions based on cysteine-bridged Mn-doped ZnS quantum dots. The sensitivity of this assay greatly increases due to the addition of cysteine. Interferences by short-lived auto-fluorescence and the scattering light from the biological fluids is eliminated by using time-resolved phosphorescence mode.

  6. Fingerprint extraction from interference destruction terahertz spectrum.

    PubMed

    Xiong, Wei; Shen, Jingling

    2010-10-11

    In this paper, periodic peaks in a terahertz absorption spectrum are confirmed to be induced from interference effects. Theoretically, we explained the periodic peaks and calculated the locations of them. Accordingly, a technique was suggested, with which the interference peaks in a terahertz spectrum can be eliminated and therefore a real terahertz absorption spectrum can be obtained. Experimentally, a sample, Methamphetamine, was investigated and its terahertz fingerprint was successfully extracted from its interference destruction spectrum. This technique is useful in getting samples' terahertz fingerprint spectra, and furthermore provides a fast nondestructive testing method using a large size terahertz beam to identify materials.

  7. Proactive Interference Slows Recognition by Eliminating Fast Assessments of Familiarity

    ERIC Educational Resources Information Center

    Oztekin, Ilke; McElree, Brian

    2007-01-01

    The response-signal speed-accuracy tradeoff (SAT) procedure was used to investigate how proactive interference (PI) affects retrieval from working memory. Participants were presented with 6-item study lists, followed immediately by a recognition probe. A variant of a release from PI design was used: All items in a list were from the same semantic…

  8. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hoffmeister, Kathryn N. Gabet; Guildenbecher, Daniel Robert; Kearney, Sean P.

    We report the application of ultrafast rotational coherent anti-Stokes Raman scattering (CARS) for temperature and relative oxygen concentration measurements in the plume emanating from a burning aluminized ammonium perchlorate propellant strand. Combustion of these metal-based propellants is a particularly hostile environment for laserbased diagnostics, with intense background luminosity, scattering and beam obstruction from hot metal particles that can be as large as several hundred microns in diameter. CARS spectra that were previously obtained using nanosecond pulsed lasers in an aluminumparticle- seeded flame are examined and are determined to be severely impacted by nonresonant background, presumably as a result of themore » plasma formed by particulateenhanced laser-induced breakdown. Introduction of fs/ps laser pulses enables CARS detection at reduced pulse energies, decreasing the likelihood of breakdown, while simultaneously providing time-gated elimination of any nonresonant background interference. Temperature probability densities and temperature/oxygen correlations were constructed from ensembles of several thousand single-laser-shot measurements from the fs/ps rotational CARS measurement volume positioned within 3 mm or less of the burning propellant surface. Preliminary results in canonical flames are presented using a hybrid fs/ps vibrational CARS system to demonstrate our progress towards acquiring vibrational CARS measurements for more accurate temperatures in the very high temperature propellant burns.« less

  9. Frequent video game players resist perceptual interference.

    PubMed

    Berard, Aaron V; Cain, Matthew S; Watanabe, Takeo; Sasaki, Yuka

    2015-01-01

    Playing certain types of video games for a long time can improve a wide range of mental processes, from visual acuity to cognitive control. Frequent gamers have also displayed generalized improvements in perceptual learning. In the Texture Discrimination Task (TDT), a widely used perceptual learning paradigm, participants report the orientation of a target embedded in a field of lines and demonstrate robust over-night improvement. However, changing the orientation of the background lines midway through TDT training interferes with overnight improvements in overall performance on TDT. Interestingly, prior research has suggested that this effect will not occur if a one-hour break is allowed in between the changes. These results have suggested that after training is over, it may take some time for learning to become stabilized and resilient against interference. Here, we tested whether frequent gamers have faster stabilization of perceptual learning compared to non-gamers and examined the effect of daily video game playing on interference of training of TDT with one background orientation on perceptual learning of TDT with a different background orientation. As a result, we found that non-gamers showed overnight performance improvement only on one background orientation, replicating previous results with the interference in TDT. In contrast, frequent gamers demonstrated overnight improvements in performance with both background orientations, suggesting that they are better able to overcome interference in perceptual learning. This resistance to interference suggests that video game playing not only enhances the amplitude and speed of perceptual learning but also leads to faster and/or more robust stabilization of perceptual learning.

  10. Low level perceptual, not attentional, processes modulate distractor interference in high perceptual load displays: evidence from neglect/extinction.

    PubMed

    Mevorach, Carmel; Tsal, Yehoshua; Humphreys, Glyn W

    2014-01-10

    According to perceptual load theory (Lavie, 2005) distractor interference is determined by the availability of attentional resources. If target processing does not exhaust resources (with low perceptual load) distractor processing will take place resulting in interference with a primary task; however, when target processing uses-up attentional capacity (with high perceptual load) interference can be avoided. An alternative account (Tsal and Benoni, 2010a) suggests that perceptual load effects can be based on distractor dilution by the mere presence of additional neutral items in high-load displays so that the effect is not driven by the amount of attention resources required for target processing. Here we tested whether patients with unilateral neglect or extinction would show dilution effects from neutral items in their contralesional (neglected/extinguished) field, even though these items do not impose increased perceptual load on the target and at the same time attract reduced attentional resources compared to stimuli in the ipsilesional field. Thus, such items do not affect the amount of attention resources available for distractor processing. We found that contralesional neutral elements can eliminate distractor interference as strongly as centrally presented ones in neglect/extinction patients, despite contralesional items being less well attended. The data are consistent with an account in terms of perceptual dilution of distracters rather than available resources for distractor processing. We conclude that distractor dilution can underlie the elimination of distractor interference in visual displays.

  11. Multiuser TOA Estimation Algorithm in DS-CDMA Sparse Channel for Radiolocation

    NASA Astrophysics Data System (ADS)

    Kim, Sunwoo

    This letter considers multiuser time delay estimation in a sparse channel environment for radiolocation. The generalized successive interference cancellation (GSIC) algorithm is used to eliminate the multiple access interference (MAI). To adapt GSIC to sparse channels the alternating maximization (AM) algorithm is considered, and the continuous time delay of each path is estimated without requiring a priori known data sequences.

  12. Cognitive control of familiarity: directed forgetting reduces proactive interference in working memory.

    PubMed

    Festini, Sara B; Reuter-Lorenz, Patricia A

    2014-03-01

    Proactive interference (PI) occurs when previously learned information interferes with new learning. In a working memory task, PI induces longer response times and more errors to recent negative probes than to new probes, presumably because the recent probe's familiarity invites a "yes" response. Warnings, longer intertrial intervals, and the increased contextual salience of the probes can reduce but not eliminate PI, suggesting that cognitive control over PI is limited. Here we tested whether control exerted in the form of intentional forgetting performed during working memory can reduce the magnitude of PI. In two experiments, participants performed a working memory task with directed-forgetting instructions and the occasional presentation of recent probes. Surprise long-term memory testing indicated better memory for to-be-remembered than for to-be-forgotten items, documenting the classic directed-forgetting effect. Critically, in working memory, PI was virtually eliminated for recent probes from prior to-be-forgotten lists, as compared to recent probes from prior to-be-remembered lists. Thus cognitive control, when executed via directed forgetting, can reduce the adverse and otherwise persistent interference from familiarity, an effect that we attribute to attenuated memory representations of the to-be-forgotten items.

  13. A Location-Based Duplex Scheme for Cost Effective Rural Broadband Connectivity Using IEEE 802.22 Cognitive Radio Based Wireless Regional Area Networks

    NASA Astrophysics Data System (ADS)

    Kalidoss, R.; Bhagyaveni, M. A.; Vishvaksenan, K. S.

    2014-08-01

    The search for a method of utilizing the scarce spectrum in an efficient manner is an active area of research in both academic and industrial communities. IEEE 802.22 is a standard for wireless regional area network (WRAN) based on cognitive radio (CR) that operates over underutilized portions of TV bands (54-862 MHz). Time division duplex (TDD)-based WRAN cells have such advantages as dynamic traffic allocation, traffic asymmetry to users and ease of spectrum allocation. However, these cells suffer from severe cross time slot (CTS) interference when the frames of the cells are not synchronized with adjacent WRAN cells. In this paper, we evaluate the location-based duplex (LBD) scheme for eliminating the CTS interference. The proposed LBD system is much more flexible and efficient in providing asymmetric data service and eliminating CTS interference by exploiting the advantages of both TDD and frequency division duplex (FDD) schemes. We also compare the performance of LBD systems with virtual cell concepts. Furthermore, our simulation results reveal that LBD-based systems outperform the virtual cell approach in terms of the low signal-to-interference (SIR) ratio requirement by mitigating the effects of CTS.

  14. [Determination of Heavy Metal Elements in Diatomite Filter Aid by Inductively Coupled Plasma Mass Spectrometry].

    PubMed

    Nie, Xi-du; Fu, Liang

    2015-11-01

    This study established a method for determining Be, Cr, Ni, As, Cd, Sb, Sn, Tl, Hg and Pb, total 10 heavy metals in diatomite filter aid. The diatomite filter aid was digested by using the mixture acid of HNO₃ + HF+ H₃PO₄ in microwave system, 10 heavy metals elements were determined by inductively coupled plasma mass spectrometry (ICP-MS). The interferences of mass spectrometry caused by the high silicon substrate were optimized, first the equipment parameters and isotopes of test metals were selected to eliminate these interferences, the methane was selected as reactant gas, and the mass spectral interferences were eliminated by dynamic reaction cell (DRC). Li, Sc, Y, In and Bi were selected as the internal standard elements to correct the interferences caused by matrix and the drift of sensitivity. The results show that the detection limits for analyte is in the range of 3.29-15.68 ng · L⁻¹, relative standard deviations (RSD) is less than 4.62%, and the recovery is in the range of 90.71%-107.22%. The current method has some advantages such as, high sensitivity, accurate, and precision, which can be used in diatomite filter aid quality control and safety estimations.

  15. Phase shifting interferometry based on a vibration sensor - feasibility study on elimination of the depth degeneracy

    NASA Astrophysics Data System (ADS)

    Lee, Seung Seok; Kim, Ju Ha; Choi, Eun Seo

    2017-04-01

    We proposed novel phase-shifting interferometry using a fiber-optic vibration sensor. The Doppler shift in the coiled fiber caused by vibrations can be used to detect the vibrations by using a fiber-optic interferometer. The principle can be applied to induce phase shifts. While applying vibrations to the coiled fiber at various vibration frequencies, we recorded the variations in the interference fringes. The interference fringe moved to longer wavelengths when a vibration frequency was increased from 38.00 to 38.40 kHz. Phase variations of 3.59 rad/kHz were obtained. The ability to accurately control the phase by using the vibrations in the coiled fiber was demonstrated by the elimination of the depth degeneracy using the complex signal generated by the phase-shifted interference fringes. Using vibrations to control phase shifting can be an acceptable alternative to conventional methods and can be applied to resolve the depth ambiguity in Fourier domain optical coherence tomography.

  16. The functional determinants of short-term memory: Evidence from perceptual-motor interference in verbal serial recall.

    PubMed

    Hughes, Robert W; Marsh, John E

    2017-04-01

    A functional, perceptual-motor, account of serial short-term memory (STM) is examined by investigating the way in which an irrelevant spoken sequence interferes with verbal serial recall. Even with visual list-presentation, verbal serial recall is particularly susceptible to disruption by irrelevant spoken stimuli that have the same identity as-but that are order-incongruent with-the to-be-remembered items. We test the view that such interference is because of the obligatory perceptual organization of the spoken stimuli yielding a sequence that competes with a subvocal motor-plan assembled to support the reproduction of the to-be-remembered list. In support of this view, the interference can be eliminated without changing either the identities or objective serial order of the spoken stimuli but merely by promoting a subjective perceptual organization that strips them of their order-incongruent relation to the to-be-remembered list (Experiment 1). The interference is also eliminated if subvocal motor sequence-planning is impeded via articulatory suppression (Experiment 2). The results are in line with the view that performance-limits in verbal serial STM are because of having to exploit perceptual and motor processes for purposes for which they did not evolve, not the inherently limited capacity of structures or mechanisms dedicated to storage. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  17. Defining the molecular profile of planarian pluripotent stem cells using a combinatorial RNA-seq, RNA interference and irradiation approach

    PubMed Central

    2012-01-01

    Background Planarian stem cells, or neoblasts, drive the almost unlimited regeneration capacities of freshwater planarians. Neoblasts are traditionally described by their morphological features and by the fact that they are the only proliferative cell type in asexual planarians. Therefore, they can be specifically eliminated by irradiation. Irradiation, however, is likely to induce transcriptome-wide changes in gene expression that are not associated with neoblast ablation. This has affected the accurate description of their specific transcriptomic profile. Results We introduce the use of Smed-histone-2B RNA interference (RNAi) for genetic ablation of neoblast cells in Schmidtea mediterranea as an alternative to irradiation. We characterize the rapid, neoblast-specific phenotype induced by Smed-histone-2B RNAi, resulting in neoblast ablation. We compare and triangulate RNA-seq data after using both irradiation and Smed-histone-2B RNAi over a time course as means of neoblast ablation. Our analyses show that Smed-histone-2B RNAi eliminates neoblast gene expression with high specificity and discrimination from gene expression in other cellular compartments. We compile a high confidence list of genes downregulated by both irradiation and Smed-histone-2B RNAi and validate their expression in neoblast cells. Lastly, we analyze the overall expression profile of neoblast cells. Conclusions Our list of neoblast genes parallels their morphological features and is highly enriched for nuclear components, chromatin remodeling factors, RNA splicing factors, RNA granule components and the machinery of cell division. Our data reveal that the regulation of planarian stem cells relies on posttranscriptional regulatory mechanisms and suggest that planarians are an ideal model for this understudied aspect of stem cell biology. PMID:22439894

  18. [Efficiency evaluation of capsaicinoids to discriminate bio-waste oils from edible vegetable oils].

    PubMed

    Mao, Lisha; Liu, Honghe; Kang, Li; Jiang, Jie; Liao, Shicheng; Liu, Guihua; Deng, Pingjian

    2014-07-01

    To evaluate the efficiency of capsaicinoids to discriminate bio-waste oil from edible vegetable oil. 14 raw vegetable oils, 24 fried waste oils, 34 kitchen-waste oils, 32 edible non-peanut vegetable oil, 32 edible peanuts oil, 16 edible oil add flavorand and 11 refined bio-waste oils were prepared and examined for capsaicinoids including capsaicin, dihydrocapsaicin and nonylic acid vanillylamide. The detection results of the above samples were statistically tested based on sample category to assessment identify the effectiveness of the bio-waste oils with capsaicinoids. As a indicator, capsaincin was possessed of high detection sensitivity and has the highest efficiency to discern kitchen-waste oils and refined bio-waste oils samples from edible non-peanut vegetable oil correctly. The accuracy rate of identification were 100% and 90.1% respectively. There is the background in peanut oil. CONCLUSION Capsaicin added in cooking process can be retained in the refining process and hardly be removed in the refining process. In the case of fully eliminating the background interference, capsaicinoids can effectively identify bio-waste oils and edible vegetable oil in combination.

  19. Integration of promoters, inverted repeat sequences and proteomic data into a model for high silencing efficiency of coeliac disease related gliadins in bread wheat

    PubMed Central

    2013-01-01

    Background Wheat gluten has unique nutritional and technological characteristics, but is also a major trigger of allergies and intolerances. One of the most severe diseases caused by gluten is coeliac disease. The peptides produced in the digestive tract by the incomplete digestion of gluten proteins trigger the disease. The majority of the epitopes responsible reside in the gliadin fraction of gluten. The location of the multiple gliadin genes in blocks has to date complicated their elimination by classical breeding techniques or by the use of biotechnological tools. As an approach to silence multiple gliadin genes we have produced 38 transgenic lines of bread wheat containing combinations of two endosperm-specific promoters and three different inverted repeat sequences to silence three fractions of gliadins by RNA interference. Results The effects of the RNA interference constructs on the content of the gluten proteins, total protein and starch, thousand seed weights and SDSS quality tests of flour were analyzed in these transgenic lines in two consecutive years. The characteristics of the inverted repeat sequences were the main factor that determined the efficiency of silencing. The promoter used had less influence on silencing, although a synergy in silencing efficiency was observed when the two promoters were used simultaneously. Genotype and the environment also influenced silencing efficiency. Conclusions We conclude that to obtain wheat lines with an optimum reduction of toxic gluten epitopes one needs to take into account the factors of inverted repeat sequences design, promoter choice and also the wheat background used. PMID:24044767

  20. FastICA peel-off for ECG interference removal from surface EMG.

    PubMed

    Chen, Maoqi; Zhang, Xu; Chen, Xiang; Zhu, Mingxing; Li, Guanglin; Zhou, Ping

    2016-06-13

    Multi-channel recording of surface electromyographyic (EMG) signals is very likely to be contaminated by electrocardiographic (ECG) interference, specifically when the surface electrode is placed on muscles close to the heart. A novel fast independent component analysis (FastICA) based peel-off method is presented to remove ECG interference contaminating multi-channel surface EMG signals. Although demonstrating spatial variability in waveform shape, the ECG interference in different channels shares the same firing instants. Utilizing the firing information estimated from FastICA, ECG interference can be separated from surface EMG by a "peel off" processing. The performance of the method was quantified with synthetic signals by combining a series of experimentally recorded "clean" surface EMG and "pure" ECG interference. It was demonstrated that the new method can remove ECG interference efficiently with little distortion to surface EMG amplitude and frequency. The proposed method was also validated using experimental surface EMG signals contaminated by ECG interference. The proposed FastICA peel-off method can be used as a new and practical solution to eliminating ECG interference from multichannel EMG recordings.

  1. Utility of high-resolution accurate MS to eliminate interferences in the bioanalysis of ribavirin and its phosphate metabolites.

    PubMed

    Wei, Cong; Grace, James E; Zvyaga, Tatyana A; Drexler, Dieter M

    2012-08-01

    The polar nucleoside drug ribavirin (RBV) combined with IFN-α is a front-line treatment for chronic hepatitis C virus infection. RBV acts as a prodrug and exerts its broad antiviral activity primarily through its active phosphorylated metabolite ribavirin 5´-triphosphate (RTP), and also possibly through ribavirin 5´-monophosphate (RMP). To study RBV transport, diffusion, metabolic clearance and its impact on drug-metabolizing enzymes, a LC-MS method is needed to simultaneously quantify RBV and its phosphorylated metabolites (RTP, ribavirin 5´-diphosphate and RMP). In a recombinant human UGT1A1 assay, the assay buffer components uridine and its phosphorylated derivatives are isobaric with RBV and its phosphorylated metabolites, leading to significant interference when analyzed by LC-MS with the nominal mass resolution mode. Presented here is a LC-MS method employing LC coupled with full-scan high-resolution accurate MS analysis for the simultaneous quantitative determination of RBV, RMP, ribavirin 5´-diphosphate and RTP by differentiating RBV and its phosphorylated metabolites from uridine and its phosphorylated derivatives by accurate mass, thus avoiding interference. The developed LC-high-resolution accurate MS method allows for quantitation of RBV and its phosphorylated metabolites, eliminating the interferences from uridine and its phosphorylated derivatives in recombinant human UGT1A1 assays.

  2. Temperature measurements in metalized propellant combustion using hybrid fs/ps coherent anti-Stokes Raman scattering.

    PubMed

    Kearney, Sean P; Guildenbecher, Daniel R

    2016-06-20

    We apply ultrafast pure-rotational coherent anti-Stokes Raman scattering (CARS) for temperature and relative oxygen concentration measurements in the plume emanating from a burning, aluminized ammonium-perchlorate propellant strand. Combustion of these metal-based propellants is a particularly hostile environment for laser-based diagnostics, with intense background luminosity and scattering from hot metal particles as large as several hundred micrometers in diameter. CARS spectra that were previously obtained using nanosecond pulsed lasers in an aluminum-particle-seeded flame are examined and are determined to be severely impacted by nonresonant background, presumably as a result of the plasma formed by particulate-enhanced laser-induced breakdown. Introduction of femtosecond/picosecond (fs/ps) laser pulses improves CARS detection by providing time-gated elimination of strong nonresonant background interference. Single-laser-shot fs/ps CARS spectra were acquired from the burning propellant plume, with picosecond probe-pulse delays of 0 and 16 ps from the femtosecond pump and Stokes pulses. At zero delay, nonresonant background overwhelms the Raman-resonant spectroscopic features. Time-delayed probing results in the acquisition of background-free spectra that were successfully fit for temperature and relative oxygen content. Temperature probability densities and temperature/oxygen correlations were constructed from ensembles of several thousand single-laser-shot measurements with the CARS measurement volume positioned within 3 mm or less of the burning propellant surface. The results show that ultrafast CARS is a potentially enabling technology for probing harsh, particle-laden flame environments.

  3. Temperature measurements in metalized propellant combustion using hybrid fs/ps coherent anti-Stokes Raman scattering

    DOE PAGES

    Kearney, Sean P.; Guildenbecher, Daniel R.

    2016-06-20

    We apply ultrafast pure-rotational coherent anti-Stokes Raman scattering (CARS) for temperature and relative oxygen concentration measurements in the plume emanating from a burning, aluminized ammonium-perchlorate propellant strand. Combustion of these metal-based propellants is a particularly hostile environment for laser-based diagnostics, with intense background luminosity and scattering from hot metal particles as large as several hundred micrometers in diameter. CARS spectra that were previously obtained using nanosecond pulsed lasers in an aluminum-particle-seeded flame are examined and are determined to be severely impacted by nonresonant background, presumably as a result of the plasma formed by particulate-enhanced laser-induced breakdown. Introduction of femtosecond/picosecond (fs/ps)more » laser pulses improves CARS detection by providing time-gated elimination of strong nonresonant background interference. Single-laser-shot fs/ps CARS spectra were acquired from the burning propellant plume, with picosecond probe-pulse delays of 0 and 16 ps from the femtosecond pump and Stokes pulses. At zero delay, nonresonant background overwhelms the Raman-resonant spectroscopic features. Time-delayed probing results in the acquisition of background-free spectra that were successfully fit for temperature and relative oxygen content. Temperature probability densities and temperature/oxygen correlations were constructed from ensembles of several thousand single-laser-shot measurements with the CARS measurement volume positioned within 3 mm or less of the burning propellant surface. Lastly, the results show that ultrafast CARS is a potentially enabling technology for probing harsh, particle-laden flame environments.« less

  4. Temperature measurements in metalized propellant combustion using hybrid fs/ps coherent anti-Stokes Raman scattering

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kearney, Sean P.; Guildenbecher, Daniel R.

    We apply ultrafast pure-rotational coherent anti-Stokes Raman scattering (CARS) for temperature and relative oxygen concentration measurements in the plume emanating from a burning, aluminized ammonium-perchlorate propellant strand. Combustion of these metal-based propellants is a particularly hostile environment for laser-based diagnostics, with intense background luminosity and scattering from hot metal particles as large as several hundred micrometers in diameter. CARS spectra that were previously obtained using nanosecond pulsed lasers in an aluminum-particle-seeded flame are examined and are determined to be severely impacted by nonresonant background, presumably as a result of the plasma formed by particulate-enhanced laser-induced breakdown. Introduction of femtosecond/picosecond (fs/ps)more » laser pulses improves CARS detection by providing time-gated elimination of strong nonresonant background interference. Single-laser-shot fs/ps CARS spectra were acquired from the burning propellant plume, with picosecond probe-pulse delays of 0 and 16 ps from the femtosecond pump and Stokes pulses. At zero delay, nonresonant background overwhelms the Raman-resonant spectroscopic features. Time-delayed probing results in the acquisition of background-free spectra that were successfully fit for temperature and relative oxygen content. Temperature probability densities and temperature/oxygen correlations were constructed from ensembles of several thousand single-laser-shot measurements with the CARS measurement volume positioned within 3 mm or less of the burning propellant surface. Lastly, the results show that ultrafast CARS is a potentially enabling technology for probing harsh, particle-laden flame environments.« less

  5. Speech Enhancement of Mobile Devices Based on the Integration of a Dual Microphone Array and a Background Noise Elimination Algorithm.

    PubMed

    Chen, Yung-Yue

    2018-05-08

    Mobile devices are often used in our daily lives for the purposes of speech and communication. The speech quality of mobile devices is always degraded due to the environmental noises surrounding mobile device users. Regretfully, an effective background noise reduction solution cannot easily be developed for this speech enhancement problem. Due to these depicted reasons, a methodology is systematically proposed to eliminate the effects of background noises for the speech communication of mobile devices. This methodology integrates a dual microphone array with a background noise elimination algorithm. The proposed background noise elimination algorithm includes a whitening process, a speech modelling method and an H ₂ estimator. Due to the adoption of the dual microphone array, a low-cost design can be obtained for the speech enhancement of mobile devices. Practical tests have proven that this proposed method is immune to random background noises, and noiseless speech can be obtained after executing this denoise process.

  6. Hybrid fs/ps CARS for Sooting and Particle-laden Flames

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hoffmeister, Kathryn N. Gabet; Guildenbecher, Daniel Robert; Kearney, Sean P.

    2015-12-01

    We report the application of ultrafast rotational coherent anti-Stokes Raman scattering (CARS) for temperature and relative oxygen concentration measurements in the plume emanating from a burning aluminized ammonium perchlorate propellant strand. Combustion of these metal-based propellants is a particularly hostile environment for laserbased diagnostics, with intense background luminosity, scattering and beam obstruction from hot metal particles that can be as large as several hundred microns in diameter. CARS spectra that were previously obtained using nanosecond pulsed lasers in an aluminumparticle- seeded flame are examined and are determined to be severely impacted by nonresonant background, presumably as a result of themore » plasma formed by particulateenhanced laser-induced breakdown. Introduction of fs/ps laser pulses enables CARS detection at reduced pulse energies, decreasing the likelihood of breakdown, while simultaneously providing time-gated elimination of any nonresonant background interference. Temperature probability densities and temperature/oxygen correlations were constructed from ensembles of several thousand single-laser-shot measurements from the fs/ps rotational CARS measurement volume positioned within 3 mm or less of the burning propellant surface. Preliminary results in canonical flames are presented using a hybrid fs/ps vibrational CARS system to demonstrate our progress towards acquiring vibrational CARS measurements for more accurate temperatures in the very high temperature propellant burns.« less

  7. Acoustic holograms of active regions

    NASA Astrophysics Data System (ADS)

    Chou, Dean-Yi

    2008-10-01

    We propose a method to study solar magnetic regions in the solar interior with the principle of optical holography. A magnetic region in the solar interior scatters the solar background acoustic waves. The scattered waves and background waves could form an interference pattern on the solar surface. We investigate the feasibility of detecting this interference pattern on the solar surface, and using it to construct the three-dimensional scattered wave from the magnetic region with the principle of optical holography. In solar acoustic holography, the background acoustic waves play the role of reference wave; the magnetic region plays the role of the target object; the interference pattern, acoustic power map, on the solar surface plays the role of the hologram.

  8. Intelligent magnetometer with photoelectric sampler

    NASA Astrophysics Data System (ADS)

    Wang, Defang; Xu, Yan; Zhu, Minjun

    1991-08-01

    The magnetometer described in this paper introduces a photoelectric sampler and a single-chip microcomputer, thus eliminating the error that is not eliminated in the analog circuit. The application of the photoelectric segregator and the voltage-to-frequency convertor have suppressed the interference significantly. According to the requirement of measuring the magnetic field, the function of automatic searching the latching is added. The intelligent magnetometer has higher accuracy and good temperature stability.

  9. False Negatives, Canter's Background Interference Procedure, the Trail Making Test, and Epileptics.

    ERIC Educational Resources Information Center

    McKinzey, Ronald K.; And Others

    1985-01-01

    Results of correlation studies of 141 adult epileptics' scores on the Background Interference Procedure (BIP) indicated that the BIP often does not agree with abnormal neurological diagnoses but often does agree with psychiatric diagnoses of Organic Brain Syndrome (OBS). Suggests that future BIP validity studies include a behavioral measure of OBS…

  10. Lions, tigers, and bears, oh sh!t: Semantics versus tabooness in speech production.

    PubMed

    White, Katherine K; Abrams, Lise; Koehler, Sarah M; Collins, Richard J

    2017-04-01

    While both semantic and highly emotional (i.e., taboo) words can interfere with speech production, different theoretical mechanisms have been proposed to explain why interference occurs. Two experiments investigated these theoretical approaches by comparing the magnitude of these two types of interference and the stages at which they occur during picture naming. Participants named target pictures superimposed with semantic, taboo, or unrelated distractor words that were presented at three different stimulus-onset asynchronies (SOA): -150 ms, 0 ms, or +150 ms. In addition, the duration of distractor presentation was manipulated across experiments, with distractors appearing for the duration of the picture (Experiment 1) or for 350 ms (Experiment 2). Taboo distractors interfered more than semantic distractors, i.e., slowed target naming times, at all SOAs. While distractor duration had no effect on type of interference at -150 or 0 SOAs, briefly presented distractors eliminated semantic interference but not taboo interference at +150 SOA. Discussion focuses on how existing speech production theories can explain interference from emotional distractors and the unique role that attention may play in taboo interference.

  11. Lifting wavelet method of target detection

    NASA Astrophysics Data System (ADS)

    Han, Jun; Zhang, Chi; Jiang, Xu; Wang, Fang; Zhang, Jin

    2009-11-01

    Image target recognition plays a very important role in the areas of scientific exploration, aeronautics and space-to-ground observation, photography and topographic mapping. Complex environment of the image noise, fuzzy, all kinds of interference has always been to affect the stability of recognition algorithm. In this paper, the existence of target detection in real-time, accuracy problems, as well as anti-interference ability, using lifting wavelet image target detection methods. First of all, the use of histogram equalization, the goal difference method to obtain the region, on the basis of adaptive threshold and mathematical morphology operations to deal with the elimination of the background error. Secondly, the use of multi-channel wavelet filter wavelet transform of the original image de-noising and enhancement, to overcome the general algorithm of the noise caused by the sensitive issue of reducing the rate of miscarriage of justice will be the multi-resolution characteristics of wavelet and promotion of the framework can be designed directly in the benefits of space-time region used in target detection, feature extraction of targets. The experimental results show that the design of lifting wavelet has solved the movement of the target due to the complexity of the context of the difficulties caused by testing, which can effectively suppress noise, and improve the efficiency and speed of detection.

  12. Development and characterization of a FIA system for selective assay of L-ascorbic acid in food samples.

    PubMed

    Vig, Attila; Igloi, Attila; Adanyi, Nora; Gyemant, Gyongyi; Csutoras, Csaba; Kiss, Attila

    2010-10-01

    An amperometric detector and an enzymatic reaction were combined for the measurement of L-ascorbic acid. The enzyme cell (containing immobilized ascorbate oxidase) was connected to a flow injection analyzer (FIA) system with a glassy carbon electrode as an amperometric detector. During optimization and measurements two sample injectors were used, one before and one after the enzyme cell, thus eliminating the background interferences. Subtraction of the signal area given in the presence of enzyme from the one given in the absence of enzyme was applied for measuring analyte concentrations and calibration at 400 mV. Analysis capacity of system is 25 samples/hour. The relative standard deviation (RSD) was below 5% (5 times repeated, 400 μmol/L conc.), linearity up to 400 μmol/L, limit of detection (LOD) 5 μmol/L, fitting of calibration curve in 25-400 μmol/L range was R (2) = 0.99.

  13. Miniaturized time-resolved Raman spectrometer for planetary science based on a fast single photon avalanche diode detector array.

    PubMed

    Blacksberg, Jordana; Alerstam, Erik; Maruyama, Yuki; Cochrane, Corey J; Rossman, George R

    2016-02-01

    We present recent developments in time-resolved Raman spectroscopy instrumentation and measurement techniques for in situ planetary surface exploration, leading to improved performance and identification of minerals and organics. The time-resolved Raman spectrometer uses a 532 nm pulsed microchip laser source synchronized with a single photon avalanche diode array to achieve sub-nanosecond time resolution. This instrument can detect Raman spectral signatures from a wide variety of minerals and organics relevant to planetary science while eliminating pervasive background interference caused by fluorescence. We present an overview of the instrument design and operation and demonstrate high signal-to-noise ratio Raman spectra for several relevant samples of sulfates, clays, and polycyclic aromatic hydrocarbons. Finally, we present an instrument design suitable for operation on a rover or lander and discuss future directions that promise great advancement in capability.

  14. Time-Resolved Detection of Fingermarks on Non-Porous and Semi-Porous Substrates Using Sr2MgSi2O7:Eu2+, Dy3+ Phosphors.

    PubMed

    Xiong, Xiaobo; Yuan, Ximing; Song, Jiangqi; Yin, Guoxiang

    2016-06-01

    Eu(2+), Dy(3+) co-doped strontium-magnesium silicate phosphors, Sr2MgSi2O7:Eu(2+), Dy(3+) (SMSEDs), have shown great potential in optoelectronic device due to their unique luminescent property. However, their potential applications in forensic science, latent fingermark detection in particular, are still being investigated. In this contribution, SMSEDs were successfully employed to latent fingermarks on a variety of non-porous and semi-porous surfaces, including aluminum foil, porcelain, glass, painted wood, colored paper, and leather. All the results illustrated that this luminescent powder, as a long-lasting phosphorescence material (LLP), was an ideal time-resolved detection reagent of fingermark for elimination of background interferences from various difficult substrates, and offered a good contrast to allow their identification without the need to enhance the results compared to nanosized organic fluorescent powder. © The Author(s) 2016.

  15. EDC EXPOSURE METHODS

    EPA Science Inventory

    Endocrine disrupter compounds (EDCs) are exogenous agents that interfere with the production, release, transport, metabolism, binding action, or elimination of the natural hormones in the body responsible for the maintenance of homeostasis and regulation of developmental processe...

  16. An evaluation in a modern wind tunnel of the transonic adaptive wall adjustment strategy developed by NPL in the 1940's

    NASA Technical Reports Server (NTRS)

    Lewis, M. C.

    1988-01-01

    The first documented wind tunnel employing a flexible walled test section for the purpose of eliminating wall interference was constructed in England by the National Physical Laboratory (NPL) during the late 1930's. The tunnel was transonic and designed for two-dimensional testing. In an attempt to eliminate the top and bottom wall interference effects on the model NPL developed a strategy to adjust two flexible walls to streamlined shapes. This report covers an evaluation of the NPL wall adjustment strategy in a modern wind tunnel, e.g., the Transonic Self-Streamlining Wind Tunnel (TSWT) at the University of Southampton, England. The evaluation took the form of performance comparisons with other modern strategies which have been developed for use in, and proven in, the TSWT.

  17. [The algorithm based on wavelet for canceling muscle electricity and wide range frequency of power line hum in ECG].

    PubMed

    Zhao, Jie; Hua, Mei

    2004-06-01

    To develop a wavelet noise canceller that cancels muscle electricity and power line hum in wide range of frequency. According to the feature that the QRS complex has higher frequency components, and the T, P wave have lower frequency components, the biorthogonal wavelet was selected to decompose the original signals. An interference-eliminated signal ECG was formed by reconstruction from the changed coefficients of wavelet. By using the canceller, muscle electricity and power line interference between 49 Hz and 61 Hz were eliminated from the ECG signals. This canceller works well in canceling muscle electricity, and basic and harmonic frequencies of power line hum. The canceller is also insensitive to the frequency change of power line, the same procedure is good for both 50 and 60 Hz power line hum.

  18. Proactive interference from items previously stored in visual working memory.

    PubMed

    Makovski, Tal; Jiang, Yuhong V

    2008-01-01

    This study investigates the fate of information that was previously stored in visual working memory but that is no longer needed. Previous research has found inconsistent results, with some showing effective release of irrelevant information and others showing proactive interference. Using change detection tasks of colors or shapes, we show that participants tend to falsely classify a changed item as "no change" if it matches one of the memory items on the preceding trial. The interference is spatially specific: Memory for the preceding trial interferes more if it matches the feature value and the location of a test item than if it does not. Interference results from retaining information in visual working memory, since it is absent when items on the preceding trials are passively viewed, or are attended but not memorized. We conclude that people cannot fully eliminate unwanted visual information from current working memory tasks.

  19. Single- and dual-carrier microwave noise abatement in the deep space network. [microwave antennas

    NASA Technical Reports Server (NTRS)

    Bathker, D. A.; Brown, D. W.; Petty, S. M.

    1975-01-01

    The NASA/JPL Deep Space Network (DSN) microwave ground antenna systems are presented which simultaneously uplink very high power S-band signals while receiving very low level S- and X-band downlinks. Tertiary mechanisms associated with elements give rise to self-interference in the forms of broadband noise burst and coherent intermodulation products. A long-term program to reduce or eliminate both forms of interference is described in detail. Two DSN antennas were subjected to extensive interference testing and practical cleanup program; the initial performance, modification details, and final performance achieved at several planned stages are discussed. Test equipment and field procedures found useful in locating interference sources are discussed. Practices deemed necessary for interference-free operations in the DSN are described. Much of the specific information given is expected to be easily generalized for application in a variety of similar installations. Recommendations for future investigations and individual element design are given.

  20. Effect of Chinese medicines Chan Su, Asian ginseng, Siberian ginseng, and American ginseng on a new digoxin immunoassay based on luminescent oxygen channeling technology.

    PubMed

    Dasgupta, Amitava; Syklawer, Erica; Johnson, Myrtle; Hwang, Shen-An; Boyd, Sydney A; Actor, Jeffrey K

    2011-10-01

    Chan Su, Asian ginseng, Siberian ginseng, and American ginseng are known to interfere with various digoxin immunoassays. Recently, a homogeneous sequential chemiluminescent assay for digoxin based on the luminescent oxygen channeling technology (LOCI digoxin) for application on the Dimension and Vista platform has been introduced into the market. The effects of interference by Chan Su and various ginsengs on this new immunoassay have not yet been reported. Aliquots of a drug-free serum pool were supplemented with Chan Su, Asian ginseng, Siberian ginseng, and American ginseng representing the expected in vivo concentrations after normal usage and cases of overdose. Serum digoxin concentrations were measured using the LOCI digoxin assay on the Vista 1500 analyzer. We also prepared 3 digoxin pools from patients receiving digoxin. Two digoxin pools were supplemented with these traditional medicines to investigate their effect on serum digoxin measurements. Mice were fed Chan Su extract to determine the potential of in vivo derived interfering factors. The possibility of eliminating interference of Chan Su on serum digoxin measurement was also investigated, by measuring free digoxin concentration after supplementing aliquots of the third digoxin pool with various amounts of Chan Su extract. A clinically significant interference by Chan Su with serum digoxin measurement was observed using the LOCI digoxin assay. The various ginsengs demonstrated negligible effects. In addition, apparent digoxin concentrations were observed in sera of mice after feeding them with Chan Su; the half-life of digoxin-like immunoreactive components was approximately 1 hour. Moreover, serum digoxin concentrations were significantly elevated in the presence of Chan Su, whereas the various ginsengs exhibited no effect. Monitoring free digoxin can only partly eliminate the interference of Chan Su in serum digoxin measurement. Chan Su interferes with serum digoxin measurement using the LOCI Digoxin, whereas the ginsengs demonstrated no measurable interference at clinically relevant concentrations.

  1. An Improved Time-Frequency Analysis Method in Interference Detection for GNSS Receivers

    PubMed Central

    Sun, Kewen; Jin, Tian; Yang, Dongkai

    2015-01-01

    In this paper, an improved joint time-frequency (TF) analysis method based on a reassigned smoothed pseudo Wigner–Ville distribution (RSPWVD) has been proposed in interference detection for Global Navigation Satellite System (GNSS) receivers. In the RSPWVD, the two-dimensional low-pass filtering smoothing function is introduced to eliminate the cross-terms present in the quadratic TF distribution, and at the same time, the reassignment method is adopted to improve the TF concentration properties of the auto-terms of the signal components. This proposed interference detection method is evaluated by experiments on GPS L1 signals in the disturbing scenarios compared to the state-of-the-art interference detection approaches. The analysis results show that the proposed interference detection technique effectively overcomes the cross-terms problem and also preserves good TF localization properties, which has been proven to be effective and valid to enhance the interference detection performance of the GNSS receivers, particularly in the jamming environments. PMID:25905704

  2. A biotin-drug extraction and acid dissociation (BEAD) procedure to eliminate matrix and drug interference in a protein complex anti-drug antibody (ADA) isotype specific assay.

    PubMed

    Niu, Hongmei; Klem, Thomas; Yang, Jinsong; Qiu, Yongchang; Pan, Luying

    2017-07-01

    Monitoring anti-drug antibody (ADA) responses in patients receiving protein therapeutics treatment is an important safety assessment for regulatory agencies, drug manufacturers, clinicians and patients. Recombinant human IGF-1/IGFBP-3 (rhIGF-1/rhIGFBP-3) is a 1:1 formulation of naturally occurring protein complex. The individual IGF-1 and IGFBP-3 proteins have multiple binding partners in serum matrix with high binding affinity to each other, which presents challenges in ADA assay development. We have developed a biotin-drug extraction with acid dissociation (BEAD) procedure followed by an electrochemiluminescence (ECL) direct assay to overcome matrix and drug interference. The method utilizes two step acid dissociation and excess biotin-drug to extract total ADA, which are further captured by soluble biotin-drug and detected in an ECL semi-homogeneous direct assay format. The pre-treatment method effectively eliminates interference by serum matrix and free drug, and enhances assay sensitivity. The assays passed acceptance criteria for all validation parameters, and have been used for clinical sample Ab testing. This method principle exemplifies a new approach for anti-isotype ADA assays, and could be an effective strategy for neutralizing antibody (NAb), pharmacokinetic (PK) and biomarker analysis in need of overcoming interference factors. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Where have we gone wrong? Perceptual load does not affect selective attention.

    PubMed

    Benoni, Hanna; Tsal, Yehoshua

    2010-06-18

    The theory of perceptual load (Lavie & Tsal, 1994) proposes that with low load in relevant processing left over resources spill over to process irrelevant distractors. Interference could only be prevented under High-Load Conditions where relevant processing exhausts attentional resources. The theory is based primarily on the finding that distractor interference obtained in low load displays, when the target appears alone, is eliminated in high load displays when it is embedded among neutral letters. However, a possible alternative interpretation of this effect is that the distractor is similarly processed in both displays, yet its interference in the large displays is diluted by the presence of the neutral letters. We separated the possible effects of load and dilution by adding dilution displays that were high in dilution and low in perceptual load. In the first experiment these displays contained as many letters as the high load displays, but their neutral letters were clearly distinguished from the target, thereby allowing for a low load processing mode. In the second experiment we presented identical multicolor displays in the Dilution and High-Load Conditions. However, in the former the target color was known in advance (thereby preserving a low load processing mode) whereas in the latter it was not. In both experiments distractor interference was completely eliminated under the Dilution Condition. Thus, it is dilution not perceptual load affecting distractor processing. 2010 Elsevier Ltd. All rights reserved.

  4. Matrix precipitation: a general strategy to eliminate matrix interference for pharmaceutical toxic impurities analysis.

    PubMed

    Yang, Xiaojing; Xiong, Xuewu; Cao, Ji; Luan, Baolei; Liu, Yongjun; Liu, Guozhu; Zhang, Lei

    2015-01-30

    Matrix interference, which can lead to false positive/negative results, contamination of injector or separation column, incompatibility between sample solution and the selected analytical instrument, and response inhibition or even quenching, is commonly suffered for the analysis of trace level toxic impurities in drug substance. In this study, a simple matrix precipitation strategy is proposed to eliminate or minimize the above stated matrix interference problems. Generally, a sample of active pharmaceutical ingredients (APIs) is dissolved in an appropriate solvent to achieve the desired high concentration and then an anti-solvent is added to precipitate the matrix substance. As a result, the target analyte is extracted into the mixed solution with very less residual of APIs. This strategy has the characteristics of simple manipulation, high recovery and excellent anti-interference capability. It was found that the precipitation ratio (R, representing the ability to remove matrix substance) and the proportion of solvent (the one used to dissolve APIs) in final solution (P, affecting R and also affecting the method sensitivity) are two important factors of the precipitation process. The correlation between R and P was investigated by performing precipitation with various APIs in different solvent/anti-solvent systems. After a detailed mathematical reasoning process, P=20% was proved to be an effective and robust condition to perform the precipitation strategy. The precipitation method with P=20% can be used as a general strategy for toxic impurity analysis in APIs. Finally, several typical examples are described in this article, where the challenging matrix interference issues have been resolved successfully. Copyright © 2014 Elsevier B.V. All rights reserved.

  5. Modified RF coaxial connector ends vacuum chamber wiring problem

    NASA Technical Reports Server (NTRS)

    Weiner, D.

    1964-01-01

    A standard radio frequency coaxial connector is modified so that a plastic insulating sleeve can be mounted in the wall of a vacuum chamber. This eliminates ground loops and interference from cable connections.

  6. Interferometric rotation sensor

    NASA Technical Reports Server (NTRS)

    Walsh, T. M.

    1972-01-01

    Sensor generates interference fringes varying in number (horizontally and vertically) as a function of the total angular deviation relative to the line-of-sight axis. Device eliminates errors from zero or null shift due to lack of electrical circuitry stability.

  7. The Stroop Revisited: A Meta-Analysis of Interference Control in AD/HD

    ERIC Educational Resources Information Center

    Van Mourik, Rosa; Oosterlaan, Jaap; Sergeant, Joseph A.

    2005-01-01

    Background: An inhibition deficit, including poor interference control, has been implicated as one of the core deficits in AD/HD. Interference control is clinically measured by the Stroop Colour-Word Task. The aim of this meta-analysis was to investigate the strength of an interference deficit in AD/HD as measured by the Stroop Colour-Word Task…

  8. [Evaluation of Sugar Content of Huanghua Pear on Trees by Visible/Near Infrared Spectroscopy].

    PubMed

    Liu, Hui-jun; Ying, Yi-bin

    2015-11-01

    A method of ambient light correction was proposed to evaluate the sugar content of Huanghua pears on tree by visible/near infrared diffuse reflectance spectroscopy (Vis/NIRS). Due to strong interference of ambient light, it was difficult to collect the efficient spectral of pears on tree. In the field, covering the fruits with a bag blocking ambient light can get better results, but the efficiency is fairly low, the instrument corrections of dark and reference spectra may help to reduce the error of the model, however, the interference of the ambient light cannot be eliminated effectively. In order to reduce the effect of ambient light, a shutter was attached to the front of probe. When opening shutter, the spot spectrum were obtained, on which instrument light and ambient light acted at the same time. While closing shutter, background spectra were obtained, on which only ambient light acted, then the ambient light spectra was subtracted from spot spectra. Prediction models were built using data on tree (before and after ambient light correction) and after harvesting by partial least square (PLS). The results of the correlation coefficient (R) are 0.1, 0.69, 0.924; the root mean square error of prediction (SEP) are 0. 89°Brix, 0.42°Brix, 0.27°Brix; ratio of standard deviation (SD) to SEP (RPD) are 0.79, 1.69, 2.58, respectively. The results indicate that, method of background correction used in the experiment can reduce the effect of ambient lighting on spectral acquisition of Huanghua pears in field, efficiently. This method can be used to collect the visible/near infrared spectrum of fruits in field, and may give full play to visible/near-infrared spectroscopy in preharvest management and maturity testing of fruits in the field.

  9. Weak beacon detection for air-to-ground optical wireless link establishment.

    PubMed

    Han, Yaoqiang; Dang, Anhong; Tang, Junxiong; Guo, Hong

    2010-02-01

    In an air-to-ground free-space optical communication system, strong background interference seriously affects the beacon detection, which makes it difficult to establish the optical link. In this paper, we propose a correlation beacon detection scheme under strong background interference conditions. As opposed to traditional beacon detection schemes, the beacon is modulated by an m-sequence at the transmitting terminal with a digital differential matched filter (DDMF) array introduced at the receiving end to detect the modulated beacon. This scheme is capable of suppressing both strong interference and noise by correlation reception of the received image sequence. In addition, the DDMF array enables each pixel of the image sensor to have its own DDMF of the same structure to process its received image sequence in parallel, thus it makes fast beacon detection possible. Theoretical analysis and an outdoor experiment have been demonstrated and show that the proposed scheme can realize fast and effective beacon detection under strong background interference conditions. Consequently, the required beacon transmission power can also be reduced dramatically.

  10. Heterophilic antibody interference affecting multiple hormone assays: Is it due to rheumatoid factor?

    PubMed

    Mongolu, Shiva; Armston, Annie E; Mozley, Erin; Nasruddin, Azraai

    2016-01-01

    Assay interference with heterophilic antibodies has been well described in literature. Rheumatoid factor is known to cause similar interference leading to falsely elevated hormone levels when measured by immunometric methods like enzyme-linked immunosorbent assay (ELISA) or multiplex immunoasays (MIA). We report a case of a 60-year-old male patient with a history of rheumatoid arthritis referred to our endocrine clinic for investigation of hypogonadism and was found to have high serum levels of LH, FSH, SHBG, Prolactin, HCG and TSH. We suspected assay interference and further tests were performed. We used Heteroblock tubes and PEG precipitation to eliminate the interference and the hormone levels post treatment were in the normal range. We believe the interference was caused by high serum levels of rheumatoid factor. Although he was treated with thyroxine for 3 years, we believe he may have been treated inappropriately as his Free T4 level was always normal despite high TSH due to assay interference. Our case illustrates the phenomenon of heterophilic antibody interference likely due to high levels of rheumatoid factor. It is essential for clinicians and endocrinologists in particular to be aware of this possibility when making treatment decisions in these groups of patients.

  11. The development of a self-streamlining flexible walled transonic test section

    NASA Technical Reports Server (NTRS)

    Goodyer, M. J.; Wolf, S. W. D.

    1980-01-01

    This design eliminates the uncertainties in data from conventional transonic test sections. Sidewalls are rigid, and the flexible floor and ceiling are positioned by motorized jacks controlled by on-line computer to minimize run times. The tunnel-computer combination is self-streamlining without reference to the model. Data is taken from the model only when the walls are good streamlines, and is corrected for the small, known but inevitable residual interferences. Two-dimensional validation testing in the Mach range up to about 0.85 where the walls are just supercritical shows good agreement with reference data using a height:chord ratio of 1.5. Techniques are under development to extend Mach number above 1. This work has demonstrated the feasibility of almost eliminating wall interferences, improving flow quality, and reducing power requirements or increasing Reynolds number. Extensions to three-dimensional testing are outlined.

  12. RELATIONSHIP BETWEEN PERCEPTION AND LEARNING IN THE MENTALLY RETARDED.

    ERIC Educational Resources Information Center

    JOHNSON, G. ORVILLE

    SUPPORTIVE EVIDENCE IS GIVEN AGAINST PERCEPTUAL DISORDERS CREATING INTERFERENCE IN LEARNING. THE CONTENTION THAT A PERCEPTUAL FIGURE GROUND DISTURBANCE NECESSARILY INTERFERES WITH THE LEARNING PROCESS IS NOT SUPPORTED BY THE EVIDENCE. THERE ARE INDICATIONS, HOWEVER, THAT BACKGROUND INTERFERENCE SEEMS TO AFFECT SOME CHILDREN MORE THAN OTHERS. TWO…

  13. Rapid method for protein quantitation by Bradford assay after elimination of the interference of polysorbate 80.

    PubMed

    Cheng, Yongfeng; Wei, Haiming; Sun, Rui; Tian, Zhigang; Zheng, Xiaodong

    2016-02-01

    Bradford assay is one of the most common methods for measuring protein concentrations. However, some pharmaceutical excipients, such as detergents, interfere with Bradford assay even at low concentrations. Protein precipitation can be used to overcome sample incompatibility with protein quantitation. But the rate of protein recovery caused by acetone precipitation is only about 70%. In this study, we found that sucrose not only could increase the rate of protein recovery after 1 h acetone precipitation, but also did not interfere with Bradford assay. So we developed a method for rapid protein quantitation in protein drugs even if they contained interfering substances. Copyright © 2015 Elsevier Inc. All rights reserved.

  14. Nonlinear transonic Wall-Interference Assessment/Correction (WIAC) procedures and application to cast-10 airfoil results from the NASA 0.3-m TCT 8- by 24-inch Slotted Wall Test Section (SWTS)

    NASA Technical Reports Server (NTRS)

    Gumbert, Clyde R.; Green, Lawrence L.; Newman, Perry A.

    1989-01-01

    From the time that wind tunnel wall interference was recognized to be significant, researchers have been developing methods to alleviate or account for it. Despite the best effort so far, it appears that no method is available which completely eliminates the effects due to the wind tunnel walls. This report discusses procedures developed for slotted wall and adaptive wall test sections of the Langley 0.3-m Transonic Cryogenic Tunnel (TCT) to assess and correct for the residual interference by methods consistent with the transonic nature of the tests.

  15. 77 FR 12053 - Information Collection Being Reviewed by the Federal Communications Commission Under Delegated...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-28

    ...; (c) ways to enhance the quality, utility, and clarity of the information collected; (d) ways to... an applicant agrees to eliminate any harmful interference caused by the operation to TV reception on...

  16. An electron impact emission spectroscopy flux sensor for monitoring deposition rate at high background gas pressure with improved accuracy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lu, C.; Blissett, C. D.; Diehl, G.

    2008-07-15

    Electron impact emission spectroscopy (EIES) has been proven to be a critical tool for film composition control during codeposition processes for the fabrication of multicomponent thin film materials including the high-efficiency copper-indium-gallium-diselenide photovoltaic cells. This technique is highly specific to atomic species because the emission spectrum of each element is unique, and the typical width of atomic emission lines is very narrow. Noninterfering emission lines can generally be allocated to different atomic species. However, the electron impact emission spectra of many molecular species are often broadband in nature. When the optical emission from an EIES sensor is measured by usingmore » a wavelength selection device with a modest resolution, such as an optical filter or monochromator, the emissions from common residual gases may interfere with that from the vapor flux and cause erroneous flux measurement. The interference is most pronounced when measuring low flux density with the presence of gases such as in reactive deposition processes. This problem is solved by using a novel EIES sensor that has two electron impact excitation sources in separate compartments but with one common port for optical output. The vapor flux is allowed to pass through one compartment only. Using a tristate excitation scheme and appropriate signal processing technique, the interfering signals from residual gases can be completely eliminated from the output signal of the EIES monitor for process control. Data obtained from Cu and Ga evaporations with the presence of common residual gases such as CO{sub 2} and H{sub 2}O are shown to demonstrate the improvement in sensor performance. The new EIES sensor is capable of eliminating the effect of interfering residual gases with pressure as high as in the upper 10{sup -5} Torr range.« less

  17. Double-modulation spectroscopy of molecular ions - Eliminating the background in velocity-modulation spectroscopy

    NASA Technical Reports Server (NTRS)

    Lan, Guang; Tholl, Hans Dieter; Farley, John W.

    1991-01-01

    Velocity-modulation spectroscopy is an established technique for performing laser absorption spectroscopy of molecular ions in a discharge. However, such experiments are often plagued by a coherent background signal arising from emission from the discharge or from electronic pickup. Fluctuations in the background can obscure the desired signal. A simple technique using amplitude modulation of the laser and two lock-in amplifiers in series to detect the signal is demonstrated. The background and background fluctuations are thereby eliminated, facilitating the detection of molecular ions.

  18. Coherent amplification of X-ray scattering from meso-structures

    DOE PAGES

    Lhermitte, Julien R.; Stein, Aaron; Tian, Cheng; ...

    2017-07-10

    Small-angle X-ray scattering (SAXS) often includes an unwanted background, which increases the required measurement time to resolve the sample structure. This is undesirable in all experiments, and may make measurement of dynamic or radiation-sensitive samples impossible. Here, we demonstrate a new technique, applicable when the scattering signal is background-dominated, which reduces the requisite exposure time. Our method consists of exploiting coherent interference between a sample with a designed strongly scattering `amplifier'. A modified angular correlation function is used to extract the symmetry of the interference term; that is, the scattering arising from the interference between the amplifier and the sample.more » This enables reconstruction of the sample's symmetry, despite the sample scattering itself being well below the intensity of background scattering. Thus, coherent amplification is used to generate a strong scattering term (well above background), from which sample scattering is inferred. We validate this method using lithographically defined test samples.« less

  19. A method of reducing background fluctuation in tunable diode laser absorption spectroscopy

    NASA Astrophysics Data System (ADS)

    Yang, Rendi; Dong, Xiaozhou; Bi, Yunfeng; Lv, Tieliang

    2018-03-01

    Optical interference fringe is the main factor that leads to background fluctuation in gas concentration detection based on tunable diode laser absorption spectroscopy. The interference fringes are generated by multiple reflections or scatterings upon optical surfaces in optical path and make the background signal present an approximated sinusoidal oscillation. To reduce the fluctuation of the background, a method that combines dual tone modulation (DTM) with vibration reflector (VR) is proposed in this paper. The combination of DTM and VR can make the unwanted periodic interference fringes to be averaged out and the effectiveness of the method in reducing background fluctuation has been verified by simulation and real experiments in this paper. In the detection system based on the proposed method, the standard deviation (STD) value of the background signal is decreased to 0.0924 parts per million (ppm), which is reduced by a factor of 16 compared with that of wavelength modulation spectroscopy. The STD value of 0.0924 ppm corresponds to the absorption of 4 . 328 × 10-6Hz - 1 / 2 (with effective optical path length of 4 m and integral time of 0.1 s). Moreover, the proposed method presents a better stable performance in reducing background fluctuation in long time experiments.

  20. Fizeau simultaneous phase-shifting interferometry based on extended source

    NASA Astrophysics Data System (ADS)

    Wang, Shanshan; Zhu, Qiudong; Hou, Yinlong; Cao, Zheng

    2016-09-01

    Coaxial Fizeau simultaneous phase-shifting interferometer plays an important role in many fields for its characteristics of long optical path, miniaturization, and elimination of reference surface high-frequency error. Based on the matching of coherence between extended source and interferometer, orthogonal polarization reference wave and measurement wave can be obtained by Fizeau interferometry with Michelson interferometer preposed. Through matching spatial coherence length between preposed interferometer and primary interferometer, high contrast interference fringes can be obtained and additional interference fringes can be eliminated. Thus, the problem of separation of measurement and reference surface in the common optical path Fizeau interferometer is solved. Numerical simulation and principle experiment is conducted to verify the feasibility of extended source interferometer. Simulation platform is established by using the communication technique of DDE (dynamic data exchange) to connect Zemax and Matlab. The modeling of the extended source interferometer is realized by using Zemax. Matlab codes are programmed to automatically rectify the field parameters of the optical system and conveniently calculate the visibility of interference fringes. Combined with the simulation, the experimental platform of the extended source interferometer is established. After experimental research on the influence law of scattering screen granularity to interference fringes, the granularity of scattering screen is determined. Based on the simulation platform and experimental platform, the impacts on phase measurement accuracy of the imaging system aberration and collimation system aberration of the interferometer are analyzed. Compared the visibility relation curves between experimental measurement and simulation result, the experimental result is in line with the theoretical result.

  1. Evaluation of on-line desalter-inductively coupled plasma-mass spectrometry system for determination of Cr(III), Cr(VI), and total chromium concentrations in natural water and urine samples

    NASA Astrophysics Data System (ADS)

    Sun, Y. C.; Lin, C. Y.; Wu, S. F.; Chung, Y. T.

    2006-02-01

    We have developed a simple and convenient method for the determination of Cr(III), Cr(VI), and the total chromium concentrations in natural water and urine samples that use a flow injection on-line desalter-inductively coupled plasma-mass spectrometry system. When using aqueous ammonium chloride (pH 8) as the stripping solution, the severe interference from sodium in the matrix can be eliminated prior to inductively coupled plasma-mass spectrometry measurement, and the Cr(VI) level can be determined directly. To determine the total concentration of Cr in natural water and urine samples, we used H 2O 2 or HNO 3 to decompose the organic matter and convert all chromium species into the Cr(VI) oxidation state. To overcome the spectral interference caused by the matrix chloride ion in the resulting solutions, we employed cool plasma to successfully suppress chloride-based molecular ion interference during the inductively coupled plasma-mass spectrometry measurement. By significantly eliminating interference from the cationic and anionic components in the matrices prior to the inductively coupled plasma-mass spectrometry measurement, we found that the detection limit reached 0.18 μg L - 1 (based on 3 sigma). We validated this method through the analysis of the total chromium content in two reference materials (NIST 1643c and 2670E) and through measuring the recovery in spiked samples.

  2. Interference effects for Higgs boson mediated Z -pair plus jet production

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Campbell, John M.; Ellis, R. Keith; Furlan, Elisabetta

    2014-11-25

    Here, we study interference effects in the production channel ZZ + jet, in particular focusing on the role of the Higgs boson. This production channel receives contributions both from Higgs boson mediated diagrams via the decay H → ZZ (signal diagrams), as well as from diagrams where the Z bosons couple directly to a quark loop (background diagrams). We consider the partonic processes gggZZ and gqmore » $$\\bar{q}$$ZZ in which interference between signal and background diagrams first occurs. Since interference is primarily an off-resonant effect for the Higgs boson, we treat the Z bosons as on shell. Thus our analysis is limited to the region above threshold, where the invariant mass of the Z-pair mZZ satisfies the condition m ZZ>2m Z. In the region m ZZ > 300 GeV we find that the interference in the ZZ + jet channel is qualitatively similar to interference in the inclusive ZZ channel. Moreover, the rates are sufficient to study these effects at the LHC once jet-binned data become available.« less

  3. Effects of Bleaching by Nitrogen Deficiency on the Quantum Yield of Photosystem II in Synechocystis sp. PCC 6803 Revealed by Chl Fluorescence Measurements.

    PubMed

    Ogawa, Takako; Sonoike, Kintake

    2016-03-01

    Estimation of photosynthesis by Chl fluorescence measurement of cyanobacteria is always problematic due to the interference from respiratory electron transfer and from phycocyanin fluorescence. The interference from respiratory electron transfer could be avoided by the use of DCMU or background illumination by blue light, which oxidizes the plastoquinone pool that tends to be reduced by respiration. On the other hand, the precise estimation of photosynthesis in cells with a different phycobilisome content by Chl fluorescence measurement is difficult. By subtracting the basal fluorescence due to the phycobilisome and PSI, it becomes possible to estimate the precise maximum quantum yield of PSII in cyanobacteria. Estimated basal fluorescence accounted for 60% of the minimum fluorescence, resulting in a large difference between the 'apparent' yield and 'true' yield under high phycocyanin conditions. The calculated value of the 'true' maximum quantum yield of PSII was around 0.8, which was similar to the value observed in land plants. The results suggest that the cause of the apparent low yield reported in cyanobacteria is mainly ascribed to the interference from phycocyanin fluorescence. We also found that the 'true' maximum quantum yield of PSII decreased under nitrogen-deficient conditions, suggesting the impairment of the PSII reaction center, while the 'apparent' maximum quantum yield showed a marginal change under the same conditions. Due to the high contribution of phycocyanin fluorescence in cyanobacteria, it is essential to eliminate the influence of the change in phycocyanin content on Chl fluorescence measurement and to evaluate the 'true' photosynthetic condition. © The Author 2016. Published by Oxford University Press on behalf of Japanese Society of Plant Physiologists. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  4. Adaptive receiver structures for asynchronous CDMA systems

    NASA Astrophysics Data System (ADS)

    Rapajic, Predrag B.; Vucetic, Branka S.

    1994-05-01

    Adaptive linear and decision feedback receiver structures for coherent demodulation in asynchronous code division multiple access (CDMA) systems are considered. It is assumed that the adaptive receiver has no knowledge of the signature waveforms and timing of other users. The receiver is trained by a known training sequence prior to data transmission and continuously adjusted by an adaptive algorithm during data transmission. The proposed linear receiver is as simple as a standard single-user detector receiver consisting of a matched filter with constant coefficients, but achieves essential advantages with respect to timing recovery, multiple access interference elimination, near/far effect, narrowband and frequency-selective fading interference suppression, and user privacy. An adaptive centralized decision feedback receiver has the same advantages of the linear receiver but, in addition, achieves a further improvement in multiple access interference cancellation at the expense of higher complexity. The proposed receiver structures are tested by simulation over a channel with multipath propagation, multiple access interference, narrowband interference, and additive white Gaussian noise.

  5. SAPT units turn-on in an interference-dominant environment. [Stand Alone Pressure Transducer

    NASA Technical Reports Server (NTRS)

    Peng, W.-C.; Yang, C.-C.; Lichtenberg, C.

    1990-01-01

    A stand alone pressure transducer (SAPT) is a credit-card-sized smart pressure sensor inserted between the tile and the aluminum skin of a space shuttle. Reliably initiating the SAPT units via RF signals in a prelaunch environment is a challenging problem. Multiple-source interference may exist if more than one GSE (ground support equipment) antenna is turned on at the same time to meet the simultaneity requirement of 10 ms. A polygon model for orbiter, external tank, solid rocket booster, and tail service masts is used to simulate the prelaunch environment. Geometric optics is then applied to identify the coverage areas and the areas which are vulnerable to multipath and/or multiple-source interference. Simulation results show that the underside areas of an orbiter have incidence angles exceeding 80 deg. For multipath interference, both sides of the cargo bay areas are found to be vulnerable to a worst-case multipath loss exceeding 20 dB. Multiple-source interference areas are also identified. Mitigation methods for the coverage and interference problem are described. It is shown that multiple-source interference can be eliminated (or controlled) using the time-division-multiplexing method or the time-stamp approach.

  6. Integrating the ECG power-line interference removal methods with rule-based system.

    PubMed

    Kumaravel, N; Senthil, A; Sridhar, K S; Nithiyanandam, N

    1995-01-01

    The power-line frequency interference in electrocardiographic signals is eliminated to enhance the signal characteristics for diagnosis. The power-line frequency normally varies +/- 1.5 Hz from its standard value of 50 Hz. In the present work, the performances of the linear FIR filter, Wave digital filter (WDF) and adaptive filter for the power-line frequency variations from 48.5 to 51.5 Hz in steps of 0.5 Hz are studied. The advantage of the LMS adaptive filter in the removal of power-line frequency interference even if the frequency of interference varies by +/- 1.5 Hz from its normal value of 50 Hz over other fixed frequency filters is very well justified. A novel method of integrating rule-based system approach with linear FIR filter and also with Wave digital filter are proposed. The performances of Rule-based FIR filter and Rule-based Wave digital filter are compared with the LMS adaptive filter.

  7. Analysis of interference of QPSK and QDPSK modulation signals by mathematical

    NASA Astrophysics Data System (ADS)

    Li, Dairuo; Xu, Kai

    2017-03-01

    In today's society, with the rapid development and extensive application of the information technology of the network central station and the integrated information system technology, information plays an important role in the military communication, mastering the information right to the competition Important role, how to protect one's own security, smooth access to and transmission of information, and to maximize the elimination of interference has become an important issue at home and abroad. QPSK modulation and its improved QPSK modulation as the mainstream signal modulation, the most widely used. In this paper, the principle of QPSK and QDPSK modulation and demodulation are introduced in this paper. Then, how to interfere with QPSK modulation signal is analyzed, and the interference of QPSK modulation signal is simulated by Matlab scripting program, which can be used in the next step. And to study the next step of anti-jamming measures provided the basis and preparatory work.

  8. Study of the Efficiency of the Polarization-Diversity Reception of a Very Low Frequency Signal Against the Background of Atmospheric Noise and Jamming in the Communication-Channel Model

    NASA Astrophysics Data System (ADS)

    Metelev, S. A.; Lvov, A. V.

    2017-12-01

    We propose a model of forming the signals and interference in the very low frequency wave range. Using this model, we determine the potentials of the space-polarization interference compensators in a communication channel with natural interference and jamming.

  9. Experimental and computational characterization of photosensitized conformational effects mediated by protoporphyrin ligands on human serum albumin.

    PubMed

    Hu, Jie; Allen, Ryan; Rozinek, Sarah; Brancaleon, Lorenzo

    2017-05-17

    When investigating the interaction between proteins and protoporphyrins in aqueous solution, one typically has to contend with the tendency of the latter to form polydispersed aggregates. The interference of aggregated protoporphyrins manifests, at least, at two levels: aggregates sequester the majority of the protoporphyrin molecules in solution and prevent their interaction with the proteins, but also their presence interferes with optical experiments such as absorption and fluorescence spectroscopy. In this study we present a protocol which uses dialysis and centrifugation to eliminate the aggregates and yield solutions dominated by non-covalent complexes of albumin (HSA) and protoporphyrins. The elimination of the aggregates enabled us to observe effects which had not been previously observed such as eliminating the discrepancy between the binding constants obtained through the quenching of HSA fluorescence and the one obtained through the emission of the protoporphyrins. Moreover the elimination of the aggregated protoporphyrins enabled us to reveal the occurrence of fluorescence resonance energy transfer (FRET) between the Trp214 residue of HSA and the porphyrin ligands. FRET data were then used to estimate the location of metal free as well as Zn-protoporphyrin IX relative to the well-known location of Trp214. This information was used to refine docking simulations to find the best binding site for the two protoporphyrins. In addition we observed that the irradiation of the protoporphyrins in the visible region prompts small conformational changes in HSA that appear to be largely due to tertiary modifications.

  10. Monte Carlo source simulation technique for solution of interference reactions in INAA experiments: a preliminary report

    NASA Astrophysics Data System (ADS)

    Allaf, M. Athari; Shahriari, M.; Sohrabpour, M.

    2004-04-01

    A new method using Monte Carlo source simulation of interference reactions in neutron activation analysis experiments has been developed. The neutron spectrum at the sample location has been simulated using the Monte Carlo code MCNP and the contributions of different elements to produce a specified gamma line have been determined. The produced response matrix has been used to measure peak areas and the sample masses of the elements of interest. A number of benchmark experiments have been performed and the calculated results verified against known values. The good agreement obtained between the calculated and known values suggests that this technique may be useful for the elimination of interference reactions in neutron activation analysis.

  11. Gas-phase mercury reduction to measure total mercury in the flue gas of a coal-fired boiler.

    PubMed

    Meischen, Sandra J; Van Pelt, Vincent J; Zarate, Eugene A; Stephens, Edward A

    2004-01-01

    Gaseous elemental and total (elemental + oxidized) mercury (Hg) in the flue gas from a coal-fired boiler was measured by a modified ultraviolet (UV) spectrometer. Challenges to Hg measurement were the spectral interferences from other flue gas components and that UV measures only elemental Hg. To eliminate interference from flue gas components, a cartridge filled with gold-coated sand removed elemental Hg from a flue gas sample. The Hg-free flue gas was the reference gas, eliminating the spectral interferences. To measure total Hg by UV, oxidized Hg underwent a gas-phase, thermal-reduction in a quartz cell heated to 750 degrees C. Simultaneously, hydrogen was added to flash react with the oxygen present forming water vapor and preventing Hg re-oxidation as it exits the cell. Hg concentration results are in parts per billion by volume Hg at the flue gas oxygen concentration. The modified Hg analyzer and the Ontario Hydro method concurrently measured Hg at a field test site. Measurements were made at a 700-MW steam turbine plant with scrubber units and selective catalytic reduction. The flue gas sampled downstream of the selective catalytic reduction contained 2100 ppm SO2 and 75 ppm NOx. Total Hg measured by the Hg analyzer was within 20% of the Ontario Hydro results.

  12. Eliminating the influence of source spectrum of white light scanning interferometry through time-delay estimation algorithm

    NASA Astrophysics Data System (ADS)

    Zhou, Yunfei; Cai, Hongzhi; Zhong, Liyun; Qiu, Xiang; Tian, Jindong; Lu, Xiaoxu

    2017-05-01

    In white light scanning interferometry (WLSI), the accuracy of profile measurement achieved with the conventional zero optical path difference (ZOPD) position locating method is closely related with the shape of interference signal envelope (ISE), which is mainly decided by the spectral distribution of illumination source. For a broadband light with Gaussian spectral distribution, the corresponding shape of ISE reveals a symmetric distribution, so the accurate ZOPD position can be achieved easily. However, if the spectral distribution of source is irregular, the shape of ISE will become asymmetric or complex multi-peak distribution, WLSI cannot work well through using ZOPD position locating method. Aiming at this problem, we propose time-delay estimation (TDE) based WLSI method, in which the surface profile information is achieved by using the relative displacement of interference signal between different pixels instead of the conventional ZOPD position locating method. Due to all spectral information of interference signal (envelope and phase) are utilized, in addition to revealing the advantage of high accuracy, the proposed method can achieve profile measurement with high accuracy in the case that the shape of ISE is irregular while ZOPD position locating method cannot work. That is to say, the proposed method can effectively eliminate the influence of source spectrum.

  13. Measurement of type-I edge localized mode pulse propagation in scrape-off layer using optical system of motional Stark effect diagnostics in JT-60U

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Suzuki, T.; Oyama, N.; Asakura, N.

    2010-04-15

    Propagation of plasma ejected by type-I edge localized mode (ELM) has been measured in scrape-off layer (SOL) of the JT-60U tokamak, using optical system of motional Stark effect (MSE) diagnostics as beam emission spectroscopy (BES) diagnostics through a new technique developed. This MSE/BES system measures D{alpha} emission from heating neutral beam excited by collisions with the ejected plasma, as well as background light (e.g., bremsstrahlung). While spatio-temporal change in the beam emission gives information on propagation of the ejected plasma, the background light that is observed simultaneously in all spatial channels veils the information. In order to separate the beammore » emission and the background light, a two-wavelength detector is newly introduced into the MSE/BES system. The detector observes simultaneously at the same spatial point in two distinct wavelengths using two photomultiplier tubes through two interference filters. One of the filters is adjusted to the central wavelength of the beam emission for the MSE diagnostics, and the other is outside the beam emission spectrum. Eliminating the background light, temporal change in the net beam emission in the SOL has been evaluated. Comparing conditionally averaged beam emission with respect to 594 ELMs in a discharge at five spatial channels (0.02-0.3 m outside the main plasma near equatorial plane), radial velocity of the ELM pulse propagation in SOL is evaluated to be 0.8-1.8 km/s ({approx}1.4 km/s for least-mean-squared fitting).« less

  14. Single-shot gas-phase thermometry using pure-rotational hybrid femtosecond/picosecond coherent anti-Stokes Raman scattering.

    PubMed

    Miller, Joseph D; Roy, Sukesh; Slipchenko, Mikhail N; Gord, James R; Meyer, Terrence R

    2011-08-01

    High-repetition-rate, single-laser-shot measurements are important for the investigation of unsteady flows where temperature and species concentrations can vary significantly. Here, we demonstrate single-shot, pure-rotational, hybrid femtosecond/picosecond coherent anti-Stokes Raman scattering (fs/ps RCARS) thermometry based on a kHz-rate fs laser source. Interferences that can affect nanosecond (ns) and ps CARS, such as nonresonant background and collisional dephasing, are eliminated by selecting an appropriate time delay between the 100-fs pump/Stokes pulses and the pulse-shaped 8.4-ps probe. A time- and frequency-domain theoretical model is introduced to account for rotational-level dependent collisional dephasing and indicates that the optimal probe-pulse time delay is 13.5 ps to 30 ps. This time delay allows for uncorrected best-fit N2-RCARS temperature measurements with ~1% accuracy. Hence, the hybrid fs/ps RCARS approach can be performed with kHz-rate laser sources while avoiding corrections that can be difficult to predict in unsteady flows.

  15. Single-shot gas-phase thermometry using pure-rotational hybrid femtosecond/picosecond coherent anti-Stokes Raman scattering

    NASA Astrophysics Data System (ADS)

    Miller, Joseph D.; Roy, Sukesh; Slipchenko, Mikhail N.; Gord, James R.; Meyer, Terrence R.

    2011-08-01

    High-repetition-rate, single-laser-shot measurements are important for the investigation of unsteady flows where temperature and species concentrations can vary significantly. Here, we demonstrate single-shot, pure-rotational, hybrid femtosecond/picosecond coherent anti-Stokes Raman scattering (fs/ps RCARS) thermometry based on a kHz-rate fs laser source. Interferences that can affect nanosecond (ns) and ps CARS, such as nonresonant background and collisional dephasing, are eliminated by selecting an appropriate time delay between the 100-fs pump/Stokes pulses and the pulse-shaped 8.4-ps probe. A time- and frequency-domain theoretical model is introduced to account for rotational-level dependent collisional dephasing and indicates that the optimal probe-pulse time delay is 13.5 ps to 30 ps. This time delay allows for uncorrected best-fit N2-RCARS temperature measurements with ~1% accuracy. Hence, the hybrid fs/ps RCARS approach can be performed with kHz-rate laser sources while avoiding corrections that can be difficult to predict in unsteady flows.

  16. On-Plate Self-Desalting and Matrix-Free LDI MS Analysis of Peptides With a Surface Patterned Sample Support

    NASA Astrophysics Data System (ADS)

    Zeng, Zhoufang; Wang, Yandong; Guo, Xinhua; Wang, Ling; Lu, Nan

    2014-05-01

    A hydrophobic-hydrophilic-hydrophobic pattern has been produced on the surface of a silicon substrate for selective enrichment, self-desalting, and matrix-free analysis of peptides in a single step. Upon sample application, the sample solution is first confined in a small area by a hydrophobic F-SAM outer area, after which salt contaminants and peptides are selectively enriched in the hydrophilic and hydrophobic areas, respectively. Simultaneously, matrix background noise is significantly reduced or eliminated because of immobilization of matrix molecules. As a result, the detection sensitivity is enhanced 20-fold compared with that obtained using the usual MALDI plate, and interference-free detection is achieved in the low m/z range. In addition, peptide ions can be identified unambiguously in the presence of NH4HCO3 (100 mM), urea (1 M), and NaCl (1 M). When the device was applied to the analysis of BSA digests, the peptide recovery and protein identification confidence were greatly improved.

  17. Tracking the engraftment and regenerative capabilities of transplanted lung stem cells using fluorescent nanodiamonds

    NASA Astrophysics Data System (ADS)

    Wu, Tsai-Jung; Tzeng, Yan-Kai; Chang, Wei-Wei; Cheng, Chi-An; Kuo, Yung; Chien, Chin-Hsiang; Chang, Huan-Cheng; Yu, John

    2013-09-01

    Lung stem/progenitor cells are potentially useful for regenerative therapy, for example in repairing damaged or lost lung tissue in patients. Several optical imaging methods and probes have been used to track how stem cells incorporate and regenerate themselves in vivo over time. However, these approaches are limited by photobleaching, toxicity and interference from background tissue autofluorescence. Here we show that fluorescent nanodiamonds, in combination with fluorescence-activated cell sorting, fluorescence lifetime imaging microscopy and immunostaining, can identify transplanted CD45-CD54+CD157+ lung stem/progenitor cells in vivo, and track their engraftment and regenerative capabilities with single-cell resolution. Fluorescent nanodiamond labelling did not eliminate the cells' properties of self-renewal and differentiation into type I and type II pneumocytes. Time-gated fluorescence imaging of tissue sections of naphthalene-injured mice indicates that the fluorescent nanodiamond-labelled lung stem/progenitor cells preferentially reside at terminal bronchioles of the lungs for 7 days after intravenous transplantation.

  18. Method and apparatus for detecting dilute concentrations of radioactive xenon in samples of xenon extracted from the atmosphere

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Warburton, William K.; Hennig, Wolfgang G.

    A method and apparatus for measuring the concentrations of radioxenon isotopes in a gaseous sample wherein the sample cell is surrounded by N sub-detectors that are sensitive to both electrons and to photons from radioxenon decays. Signal processing electronics are provided that can detect events within the sub-detectors, measure their energies, determine whether they arise from electrons or photons, and detect coincidences between events within the same or different sub-detectors. The energies of detected two or three event coincidences are recorded as points in associated two or three-dimensional histograms. Counts within regions of interest in the histograms are then usedmore » to compute estimates of the radioxenon isotope concentrations. The method achieves lower backgrounds and lower minimum detectable concentrations by using smaller detector crystals, eliminating interference between double and triple coincidence decay branches, and segregating double coincidences within the same sub-detector from those occurring between different sub-detectors.« less

  19. Analytical Protocol (GC/ECNIMS) for OSWER's Response to OIG Report (2005-P-00022) on Toxaphene Analysis

    EPA Science Inventory

    The research approached the large number and complexity of the analytes as four separate groups: technical toxaphene, toxaphene congeners (eight in number), chlordane, and organochlorine pesticides. This approach was advantageous because it eliminated potential interferences amon...

  20. The Psychology of Coercion: Merging Airpower and Prospect Theory

    DTIC Science & Technology

    1998-06-01

    that a fourth airpower strategy for coercion exists in airlift, where goods and services may be provided to interfere with the adversary’s objectives...objectives; decapitation or attempts to limit/eliminate decisionmaker control; and airlift or provision of goods and services to either complicate

  1. Highlights of experience with a flexible walled test section in the NASA Langley 0.3-meter transonic cryogenic tunnel

    NASA Technical Reports Server (NTRS)

    Wolf, Stephen W. D.; Ray, Edward J.

    1988-01-01

    The unique combination of adaptive wall technology with a contonuous flow cryogenic wind tunnel is described. This powerful combination allows wind tunnel users to carry out 2-D tests at flight Reynolds numbers with wall interference essentially eliminated. Validation testing was conducted to support this claim using well tested symmetrical and cambered airfoils at transonic speeds and high Reynolds numbers. The test section hardware has four solid walls, with the floor and ceiling flexible. The method of adapting/shaping the floor and ceiling to eliminate top and bottom wall interference at its source is outlined. Data comparisons for different size models tested and others in several sophisticated 2-D wind tunnels are made. In addition, the effects of Reynolds number, testing at high lift with associated large flexible wall movements, the uniqueness of the adapted wall shapes, and the effects of sidewall boundary layer control are examined. The 0.3-m TCT is now the most advanced 2-D research facility anywhere.

  2. Improved multi-beam laser interference lithography system by vibration analysis model

    NASA Astrophysics Data System (ADS)

    Lin, Te Hsun; Yang, Yin-Kuang; Mai, Hsuan-Ying; Fu, Chien-Chung

    2017-03-01

    This paper has developed the multi-beam laser interference lithography (LIL) system for nano/micro pattern sapphire substrate process (PSS/NPSS). However, the multi-beam LIL system is very sensitive to the light source and the vibration. When there is a vibration source in the exposure environment, the standing wave distribution on the substrate will be affected by the vibration and move in a certain angle. As a result, Moiré fringe defects occur on the exposure result. In order to eliminate the effect of the vibration, we use the software ANSYS to analyze the resonant frequencies of our multi-beam LIL system. Therefore, we need to design new multi-beam LIL system to raise the value of resonant frequencies. The new design of the multi-beam LIL system has higher resonant frequencies and successfully eliminates the bending and rotating effect of the resonant frequencies. As a result, the new multi-beam LIL system can fabricate large area and defects free period structures.

  3. Research on infrared ship detection method in sea-sky background

    NASA Astrophysics Data System (ADS)

    Tang, Da; Sun, Gang; Wang, Ding-he; Niu, Zhao-dong; Chen, Zeng-ping

    2013-09-01

    An approach to infrared ship detection based on sea-sky-line(SSL) detection, ROI extraction and feature recognition is proposed in this paper. Firstly, considering that far ships are expected to be adjacent to the SSL, SSL is detected to find potential target areas. Radon transform is performed on gradient image to choose candidate SSLs, and detection result is given by fuzzy synthetic evaluation values. Secondly, in view of recognizable condition that there should be enough differences between target and background in infrared image, two gradient masks have been created and improved as practical guidelines in eliminating false alarm. Thirdly, extract ROI near the SSL by using multi-grade segmentation and fusion method after image sharpening, and unsuitable candidates are screened out according to the gradient masks and ROI shape. Finally, we segment the rest of ROIs by two-stage modified OTSU, and calculate target confidence as a standard measuring the facticity of target. Compared with other ship detection methods, proposed method is suitable for bipolar targets, which offers a good practicability and accuracy, and achieves a satisfying detection speed. Detection experiments with 200 thousand frames show that the proposed method is widely applicable, powerful in resistance to interferences and noises with a detection rate of above 95%, which satisfies the engineering needs commendably.

  4. Elimination Rates of Dioxin Congeners in Former Chlorophenol Workers from Midland, Michigan

    PubMed Central

    Collins, James J.; Bodner, Kenneth M.; Wilken, Michael; Bodnar, Catherine M.

    2012-01-01

    Background: Exposure reconstructions and risk assessments for 2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD) and other dioxins rely on estimates of elimination rates. Limited data are available on elimination rates for congeners other than TCDD. Objectives: We estimated apparent elimination rates using a simple first-order one-compartment model for selected dioxin congeners based on repeated blood sampling in a previously studied population. Methods: Blood samples collected from 56 former chlorophenol workers in 2004–2005 and again in 2010 were analyzed for dioxin congeners. We calculated the apparent elimination half-life in each individual for each dioxin congener and examined factors potentially influencing elimination rates and the impact of estimated ongoing background exposures on rate estimates. Results: Mean concentrations of all dioxin congeners in the sampled participants declined between sampling times. Median apparent half-lives of elimination based on changes in estimated mass in the body were generally consistent with previous estimates and ranged from 6.8 years (1,2,3,7,8,9-hexachlorodibenzo-p-dioxin) to 11.6 years (pentachlorodibenzo-p-dioxin), with a composite half-life of 9.3 years for TCDD toxic equivalents. None of the factors examined, including age, smoking status, body mass index or change in body mass index, initial measured concentration, or chloracne diagnosis, was consistently associated with the estimated elimination rates in this population. Inclusion of plausible estimates of ongoing background exposures decreased apparent half-lives by approximately 10%. Available concentration-dependent toxicokinetic models for TCDD underpredicted observed elimination rates for concentrations < 100 ppt. Conclusions: The estimated elimination rates from this relatively large serial sampling study can inform occupational and environmental exposure and serum evaluations for dioxin compounds. PMID:23063871

  5. Inductive Interference in Rapid Transit Signaling Systems. Volume 1. Theory and Background.

    DOT National Transportation Integrated Search

    1986-05-01

    This report describes the mechanism of inductive interference to audio frequency (AF) signaling systems used in rail transit operations, caused by rail transit vehicles with chopper propulsion control. Choppers are switching circuits composed of high...

  6. Interference correction by extracting the information of interference dominant regions: Application to near-infrared spectra

    NASA Astrophysics Data System (ADS)

    Bi, Yiming; Tang, Liang; Shan, Peng; Xie, Qiong; Hu, Yong; Peng, Silong; Tan, Jie; Li, Changwen

    2014-08-01

    Interference such as baseline drift and light scattering can degrade the model predictability in multivariate analysis of near-infrared (NIR) spectra. Usually interference can be represented by an additive and a multiplicative factor. In order to eliminate these interferences, correction parameters are needed to be estimated from spectra. However, the spectra are often mixed of physical light scattering effects and chemical light absorbance effects, making it difficult for parameter estimation. Herein, a novel algorithm was proposed to find a spectral region automatically that the interesting chemical absorbance and noise are low, that is, finding an interference dominant region (IDR). Based on the definition of IDR, a two-step method was proposed to find the optimal IDR and the corresponding correction parameters estimated from IDR. Finally, the correction was performed to the full spectral range using previously obtained parameters for the calibration set and test set, respectively. The method can be applied to multi target systems with one IDR suitable for all targeted analytes. Tested on two benchmark data sets of near-infrared spectra, the performance of the proposed method provided considerable improvement compared with full spectral estimation methods and comparable with other state-of-art methods.

  7. Event models and the fan effect.

    PubMed

    Radvansky, G A; O'Rear, Andrea E; Fisher, Jerry S

    2017-08-01

    The current study explored the persistence of event model organizations and how this influences the experience of interference during retrieval. People in this study memorized lists of sentences about objects in locations, such as "The potted palm is in the hotel." Previous work has shown that such information can either be stored in separate event models, thereby producing retrieval interference, or integrated into common event models, thereby eliminating retrieval interference. Unlike prior studies, the current work explored the impact of forgetting up to 2 weeks later on this pattern of performance. We explored three possible outcomes across the various retention intervals. First, consistent with research showing that longer delays reduce proactive and retroactive interference, any retrieval interference effects of competing event models could be reduced over time. Second, the binding of information into events models may weaken over time, causing interference effects to emerge when they had previously been absent. Third, and finally, the organization of information into event models could remain stable over long periods of time. The results reported here are most consistent with the last outcome. While there were some minor variations across the various retention intervals, the basic pattern of event model organization remained preserved over the two-week retention period.

  8. EVALUATION OF SUPERCRITICAL FLUID EXTRACTION FOR ELIMINATING INTERFERENCES DURING MULTIRESIDUE PATRICIDE ANALYSIS. (R825549C011)

    EPA Science Inventory

    The perspectives, information and conclusions conveyed in research project abstracts, progress reports, final reports, journal abstracts and journal publications convey the viewpoints of the principal investigator and may not represent the views and policies of ORD and EPA. Concl...

  9. Determining thin film properties by fitting optical transmittance

    NASA Astrophysics Data System (ADS)

    Klein, J. D.; Yen, A.; Cogan, S. F.

    1990-08-01

    The optical transmission spectra of rf sputtered tungsten oxide films on glass substrates were modeled to determine absorption edge behavior, film thickness, and index of refraction. Removal of substrate reflection and absorption phenomena from the experimental spectra allowed direct examination of thin film optical characteristics. The interference fringe pattern allows determination of the film thickness and the dependence of the real index of refraction on wavelength. Knowledge of the interference fringe behavior in the vicinity of the absorption edge was found essential to unambiguous determination of the optical band gap. In particular, the apparently random deviations commonly observed in the extrapolation of as-acquired data are eliminated by explicitly considering interference fringe phenomena. The multivariable optimization fitting scheme employed allows air-film-substrate reflection losses to be compensated without making reflectance measurements.

  10. Azomethine H colorimetric method for determining dissolved boron in water

    USGS Publications Warehouse

    Spencer, R.R.; Erdmann, D.E.

    1979-01-01

    An automated colorimetric method for determining dissolved boron in water is described. The boron is complexed with azomethine H, which is readily available as the condensation product of H acid (8-amino-1-naphthol-3,6-disulfonic acid) and salicylaldehyde. The absorbance of the yellow complex formed is then measured colorimetrically at 410 nm. Interference effects from other dissolved species are minimized by the addition of diethylenetriaminepentaacetic acid (DTPA); however, iron, zinc, and bicarbonate interfere at concentrations above 400 ??g/L, 2000 ??g/L, and 200 mg/L, respectively. The bicarbonate interference can be eliminated by careful acidification of the sample with concentrated HCl to a pH between 5 and 6. Thirty samples per hour can be routinely analyzed over the range of from 10 to 400 ??g/L, boron.

  11. ETP-0474: Evaluation of Electroless Nickel Coatings to Achieve Interference Fit in the RSRM Without Fretting

    NASA Technical Reports Server (NTRS)

    Schaffnit, William O.

    1997-01-01

    Part of the redesign of the SRMs for the Space Shuttle involved the substitution of three new capture cylinders for three of the previously used cylinders. These new cylinders mate with the old standard case segments in each of the three field joints. The new capture cylinders contain an integral capture latch on the tang end which mates with a case clevis during stackup at KSC. The capture cylinders also contain a groove in the capture latch to provide for a third 0-ring in the joint and are designed to achieve a metal-to- metal interference fit between the capture latch and the mating clevis. An unexpected fretting problem has occurred on the tang capture feature and the inner clevis leg interference fit surfaces on flight hardware since STS-26. Varying degrees of fretting damage have been found on the case segments from different flight motors. Fretting is a wear phenomena that occurs when two tightly fitting metal surfaces are subject to cyclic relative motion of extremely small amplitudes (generally less than 0.010-inch) in the absence of adequate lubrication. It is adhesive ("cold" - welding) in nature and vibration is its essential causative factor. This problem has manifested itself on the flight motors as a series of pits and axial gouges on the inside diameter (ID) surfaces of the inner clevis legs and the outside diameter (OD) surfaces of the tang capture features. The problem occurs in varying degrees of severity in all of the field joints. It is not believed that fretting is a flight safety issue. However, it could become a reusability issue if left unattended. Fretting has been encountered in other industries for many years and measures that will prevent or reduce it have been devised. These include: elimination or reduction of vibration (amplitudes and/or frequencies), elimination of slip, improved lubrication between parts, increased surface separation, increased interference, inducing residual compressive stresses in the surfaces of the mating parts, and employing non-fretting interference shims. Looking at each of these separately; vibration and slip occur in varying degrees and magnitudes in the field joints (as part of the roll-out, launch, flight, splashdown, flotation, and/or tow back) and are difficult to define or eliminate. Improved lubrication is something that was evaluated since it would be the simplest change to incorporate, but little or no improvement was found. Increasing surface separation would defeat the purpose of the interference fit. The effect of increasing the interference fit is unknown. Additional shot peening and/or surface rolling to impart residual compressive stresses in the joints undoubtedly would alter the characteristics and finish of the sealing surfaces of the motor cases. Also, experimental data' indicate that the tangs and clevises already have residual compressive stress fields on their surfaces yet fretting occurs. These stresses probably result from the case machining and the glass beading used to clean these surfaces.

  12. Mathematical Modelling of Allelopathy: IV. Assessment of Contributions of Competition and Allelopathy to Interference by Barley

    PubMed Central

    Liu, De Li; An, Min; Johnson, I.R.; Lovett, J.V.

    2005-01-01

    One of the main challenges to the research on allelopathy is technically the separation of allelopathic effect from competition, and quantitatively, the assessment of the contribution of each component to overall interference. A simple mathematical model is proposed to calculate the contribution of allelopathy and competition to interference. As an example of applying the quantitative model to interference by barley (Hordeum vulgare cv. Triumph), the approach used was an addition of allelopathic effect, by an equivalent amount, to the environment of the test plant (white mustard, Sinapis alba), rather than elimination of competition. Experiments were conducted in glasshouse to determine the magnitude of the contributions of allelopathy and competition to interference by barley. The leachates of living barley roots significantly reduced the total dry weight of white mustard. The model involved the calculation of adjusted densities to an equivalent basis for modelling the contribution of allelopathy and competition to total interference. The results showed that allelopathy contributed 40%, 37% and 43% to interference by barley at 6, 12 and 18 white mustard pot−1. The consistency in magnitude of the calculated contribution of allelopathic effect by barley across various densities of receiver plant suggested that the adjusted equivalent density is effective and that the model is able to assess the contribution of each component of interference regardless of the density of receiver plant. PMID:19330162

  13. Power line interference attenuation in multi-channel sEMG signals: Algorithms and analysis.

    PubMed

    Soedirdjo, S D H; Ullah, K; Merletti, R

    2015-08-01

    Electromyogram (EMG) recordings are often corrupted by power line interference (PLI) even though the skin is prepared and well-designed instruments are used. This study focuses on the analysis of some of the recent and classical existing digital signal processing approaches have been used to attenuate, if not eliminate, the power line interference from EMG signals. A comparison of the signal to interference ratio (SIR) of the output signals is presented, for four methods: classical notch filter, spectral interpolation, adaptive noise canceller with phase locked loop (ANC-PLL) and adaptive filter, applied to simulated multichannel monopolar EMG signals with different SIR. The effect of each method on the shape of the EMG signals is also analyzed. The results show that ANC-PLL method gives the best output SIR and lowest shape distortion compared to the other methods. Classical notch filtering is the simplest method but some information might be lost as it removes both the interference and the EMG signals. Thus, it is obvious that notch filter has the lowest performance and it introduces distortion into the resulting signals.

  14. A two-dimensional adaptive-wall test section with ventilated walls in the Ames 2- by 2-foot transonic wind tunnel

    NASA Technical Reports Server (NTRS)

    Schairer, Edward T.; Lee, George; Mcdevitt, T. Kevin

    1989-01-01

    The first tests conducted in the adaptive-wall test section of the Ames Research Center's 2- by 2-Foot Transonic Wind Tunnel are described. A procedure was demonstrated for reducing wall interference in transonic flow past a two-dimensional airfoil by actively controlling flow through the slotted walls of the test section. Flow through the walls was controlled by adjusting pressures in compartments of plenums above and below the test section. Wall interference was assessed by measuring (with a laser velocimeter) velocity distributions along a contour surrounding the model, and then checking those measurements for their compatibility with free-air far-field boundary conditions. Plenum pressures for minimum wall interference were determined from empirical influence coefficients. An NACA 0012 airfoil was tested at angles of attach of 0 and 2, and at Mach numbers between 0.70 and 0.85. In all cases the wall-setting procedure greatly reduced wall interference. Wall interference, however, was never completely eliminated, primarily because the effect of plenum pressure changes on the velocities along the contour could not be accurately predicted.

  15. Ranitidine interference with standard amphetamine immunoassay.

    PubMed

    Liu, Li; Wheeler, Sarah E; Rymer, Jacqueline A; Lower, Darla; Zona, Jayne; Peck Palmer, Octavia M; Tamama, Kenichi

    2015-01-01

    We recently encountered several cases of possible false positive results of amphetamine on the Beckman Coulter AMPH assay, but not on the Siemens EMIT II Plus assay. Our clinical chart review suggested that ranitidine interference may be responsible for the false positive results of the AMPH assays. Blank urine specimens spiked with ranitidine concentrations ranging from 5μg/ml to 5mg/ml were analyzed on both the AMPH and EMIT II Plus assays. To examine if the false positive results were due to assay specific reagent/sample ratios, we prepared 3 different sample to reagent ratios and analyzed them for amphetamine reaction rates on both assays. Ranitidine at 160μg/ml caused a positive interference on the AMPH assay. No interference was observed by ranitidine on the EMIT II Plus assay. Specifically, the sample to reagent ratios tested neither eliminated the positive inference on the AMP assay nor introduced an interference on the EMIT II Plus assay. Unlike the EMIT II Plus assay, the AMPH assay has cross-activity with ranitidine, which is independent of sample to reagent ratio. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. Generation of wideband chaos with suppressed time-delay signature by delayed self-interference.

    PubMed

    Wang, Anbang; Yang, Yibiao; Wang, Bingjie; Zhang, Beibei; Li, Lei; Wang, Yuncai

    2013-04-08

    We demonstrate experimentally and numerically a method using the incoherent delayed self-interference (DSI) of chaotic light from a semiconductor laser with optical feedback to generate wideband chaotic signal. The results show that, the DSI can eliminate the domination of laser relaxation oscillation existing in the chaotic laser light and therefore flatten and widen the power spectrum. Furthermore, the DSI depresses the time-delay signature induced by external cavity modes and improves the symmetry of probability distribution by more than one magnitude. We also experimentally show that this DSI signal is beneficial to the random number generation.

  17. Interference elimination in digital controllers of automation systems of oil and gas complex

    NASA Astrophysics Data System (ADS)

    Solomentsev, K. Yu; Fugarov, D. D.; Purchina, O. A.; Poluyan, A. Y.; Nesterchuk, V. V.; Petrenkova, S. B.

    2018-05-01

    The given article considers the problems arising in the process of digital governors development for the systems of automatic control. In the case of interference, and also in case of high frequency of digitization, digital differentiation gives a big error. The problem is that the derivative is calculated as the difference of two close variables. The method of differentiation is offered to reduce this error, when there is a case of averaging the difference quotient of the series of meanings. The structure chart for the implementation of this differentiation method is offered in the case of governors construction.

  18. Miniaturized compact water-cooled pitot-pressure probe for flow-field surveys in hypersonic wind tunnels

    NASA Technical Reports Server (NTRS)

    Ashby, George C.

    1988-01-01

    An experimental investigation of the design of pitot probes for flowfield surveys in hypersonic wind tunnels is reported. The results show that a pitot-pressure probe can be miniaturized for minimum interference effects by locating the transducer in the probe support body and water-cooling it so that the pressure-settling time and transducer temperature are compatible with hypersonic tunnel operation and flow conditions. Flowfield surveys around a two-to-one elliptical cone model in a 20-inch Mach 6 wind tunnel using such a probe show that probe interference effects are essentially eliminated.

  19. Determination of triclosan in antiperspirant gels by first-order derivative spectrophotometry.

    PubMed

    Du, Lina; Li, Miao; Jin, Yiguang

    2011-10-01

    A first-order derivative UV spectrophotometric method was developed to determine triclosan, a broad-spectrum antimicrobial agent, in health care products containing fragrances which could interfere the determination as impurities. Different extraction methods were compared. Triclosan was extracted with chloroform and diluted with ethanol followed by the derivative spectrophotometric measurement. The interference of fragrances was completely eliminated. The calibration graph was found to be linear in the range of 7.5-45 microg x mL(-1). The method is simple, rapid, sensitive and proper to determine triclosan in fragrance-containing health care products.

  20. Wing-Fuselage Interference, Tail Buffeting, and Air Flow About the Tail of a Low-Wing Monoplane

    NASA Technical Reports Server (NTRS)

    White, James A; Hood, Manley J

    1935-01-01

    This report presents the results of wind tunnel tests on a Mcdonnell Douglas airplane to determine the wing-fuselage interference of a low-wing monoplane. The tests included a study of tail buffeting and the air flow in the region of the tail. The airplane was tested with and without the propeller slipstream, both in the original condition and with several devices designed to reduce or eliminate tail buffeting. The devices used were wing-fuselage fillets, a NACA cowling, reflexed trailing edge of the wing, and stub auxiliary airfoils.

  1. CRT Monitors: Do They Interfere with Learning?

    ERIC Educational Resources Information Center

    Garland, Kate J.; Noyes, Jan M.

    2004-01-01

    Research suggests screen reading is slower and possibly less accurate than reading from paper. Six study and test sessions over 10 months examined correct scores and retrieval responses for learning material presented via these two media. Correct scores did not differ suggesting that close matching of material can eliminate any decrement in…

  2. Methods for Detecting Low-Frequency Signals in the Presence of Strong Winds

    DTIC Science & Technology

    1990-05-01

    34Two-Hydrophone Method of Eliminating the Effects of Nonacoustic Noise Interference in Measurements of Infra - sonic Ambient Noise Levels," J... Infrasonic Gradient Micro- phones and Windscreens," J. Acoustical Soc. Am., Vol 44 (November 1968), pp 1428-36. 9. M. Strasberg, "Dimensional Analysis of

  3. Is There a Genetic Basis to the Development of Alcoholism among Native Americans?

    ERIC Educational Resources Information Center

    Gill, Kathryn

    1992-01-01

    Studies of families, twins, and adoptees support a genetic predisposition to alcoholism. Alcohol metabolism may affect the regulation of alcohol intake, because interference with production or elimination of the alcohol metabolite acetaldehyde has behavioral effects. Ongoing research is examining individual and tribal differences in alcohol…

  4. Low-inductance bus lines

    NASA Technical Reports Server (NTRS)

    Kernick, A.

    1977-01-01

    Laminated bus strips and bifilar litz cable connectors for high-power rectifiers, thrisistors, and transistors provide low inductance and eliminate electromagnetic interference in high-power circuits. These techniques offer significant cost advantages because of ease of assembly and consistent high quality of product. Effectiveness makes general usage in static power conversion likely.

  5. Enzyme activity assay of glycoprotein enzymes based on a boronate affinity molecularly imprinted 96-well microplate.

    PubMed

    Bi, Xiaodong; Liu, Zhen

    2014-12-16

    Enzyme activity assay is an important method in clinical diagnostics. However, conventional enzyme activity assay suffers from apparent interference from the sample matrix. Herein, we present a new format of enzyme activity assay that can effectively eliminate the effects of the sample matrix. The key is a 96-well microplate modified with molecularly imprinted polymer (MIP) prepared according to a newly proposed method called boronate affinity-based oriented surface imprinting. Alkaline phosphatase (ALP), a glycoprotein enzyme that has been routinely used as an indicator for several diseases in clinical tests, was taken as a representative target enzyme. The prepared MIP exhibited strong affinity toward the template enzyme (with a dissociation constant of 10(-10) M) as well as superb tolerance for interference. Thus, the enzyme molecules in a complicated sample matrix could be specifically captured and cleaned up for enzyme activity assay, which eliminated the interference from the sample matrix. On the other hand, because the boronate affinity MIP could well retain the enzymatic activity of glycoprotein enzymes, the enzyme captured by the MIP was directly used for activity assay. Thus, additional assay time and possible enzyme or activity loss due to an enzyme release step required by other methods were avoided. Assay of ALP in human serum was successfully demonstrated, suggesting a promising prospect of the proposed method in real-world applications.

  6. Aerofoil testing in a self-streamlining flexible walled wind tunnel. Ph.D. Thesis - Jul. 1987

    NASA Technical Reports Server (NTRS)

    Lewis, Mark Charles

    1988-01-01

    Two-dimensional self-streamlining flexible walled test sections eliminate, as far as experimentally possible, the top and bottom wall interference effects in transonic airfoil testing. The test section sidewalls are rigid, while the impervious top and bottom walls are flexible and contoured to streamline shapes by a system of jacks, without reference to the airfoil model. The concept of wall contouring to eliminate or minimize test section boundary interference in 2-D testing was first demonstrated by NPL in England during the early 40's. The transonic streamlining strategy proposed, developed and used by NPL has been compared with several modern strategies. The NPL strategy has proved to be surprisingly good at providing a wall interference-free test environment, giving model performance indistinguishable from that obtained using the modern strategies over a wide range of test conditions. In all previous investigations the achievement of wall streamlining in flexible walled test sections has been limited to test sections up to those resulting in the model's shock just extending to a streamlined wall. This work however, has also successfully demonstrated the feasibility of 2-D wall streamlining at test conditions where both model shocks have reached and penetrated through their respective flexible walls. Appropriate streamlining procedures have been established and are uncomplicated, enabling flexible walled test sections to cope easily with these high transonic flows.

  7. TDM/FM/FDMA - A modulation technique for multiple-beam satellites which precludes cochannel interference and allows non-uniform geographic distribution of user channels

    NASA Technical Reports Server (NTRS)

    Springett, J. C.

    1982-01-01

    The technique outlined in this paper is intended to eliminate the problems of cochannel interference and uniform geographic distribution of user channels which arise in conventional designs for a multiple spot beam communication satellite to serve mobile telephony users across the CONUS. By time multiplexing FM/FDMA signal ensembles so that only those beams operating on distinct frequency subbands are allowed to transmit concurrently, cochannel interference arising from simultaneous frequency subband reuse is precluded. Thus, time disjoint frequency reuse is accomplished over a repetitive sequence of fixed time slots. By assigning different size subbands to each time slot, a market of nonuniform users can be accommodated. The technique results in a greatly simplified antenna feed system design for the satellite, at a cost of imposing the need for time slot synchronization on the mobile FM receivers whose ability for rejecting adjacent channel interference is somewhat diminished.

  8. An FPGA-based DS-CDMA multiuser demodulator employing adaptive multistage parallel interference cancellation

    NASA Astrophysics Data System (ADS)

    Li, Xinhua; Song, Zhenyu; Zhan, Yongjie; Wu, Qiongzhi

    2009-12-01

    Since the system capacity is severely limited, reducing the multiple access interfere (MAI) is necessary in the multiuser direct-sequence code division multiple access (DS-CDMA) system which is used in the telecommunication terminals data-transferred link system. In this paper, we adopt an adaptive multistage parallel interference cancellation structure in the demodulator based on the least mean square (LMS) algorithm to eliminate the MAI on the basis of overviewing various of multiuser dectection schemes. Neither a training sequence nor a pilot signal is needed in the proposed scheme, and its implementation complexity can be greatly reduced by a LMS approximate algorithm. The algorithm and its FPGA implementation is then derived. Simulation results of the proposed adaptive PIC can outperform some of the existing interference cancellation methods in AWGN channels. The hardware setup of mutiuser demodulator is described, and the experimental results based on it demonstrate that the simulation results shows large performance gains over the conventional single-user demodulator.

  9. TDM/FM/FDMA - A modulation technique for multiple-beam satellites which precludes cochannel interference and allows non-uniform geographic distribution of user channels

    NASA Astrophysics Data System (ADS)

    Springett, J. C.

    The technique outlined in this paper is intended to eliminate the problems of cochannel interference and uniform geographic distribution of user channels which arise in conventional designs for a multiple spot beam communication satellite to serve mobile telephony users across the CONUS. By time multiplexing FM/FDMA signal ensembles so that only those beams operating on distinct frequency subbands are allowed to transmit concurrently, cochannel interference arising from simultaneous frequency subband reuse is precluded. Thus, time disjoint frequency reuse is accomplished over a repetitive sequence of fixed time slots. By assigning different size subbands to each time slot, a market of nonuniform users can be accommodated. The technique results in a greatly simplified antenna feed system design for the satellite, at a cost of imposing the need for time slot synchronization on the mobile FM receivers whose ability for rejecting adjacent channel interference is somewhat diminished.

  10. Spectral and non-spectral interferences in the determination of thallium in environmental materials using electrothermal atomization and vaporization techniques—a case study

    NASA Astrophysics Data System (ADS)

    Vale, Maria Goreti R.; Welz, Bernhard

    2002-12-01

    The literature on the determination of Tl in environmental samples using electrothermal atomization (ETA) and vaporization (ETV) techniques has been reviewed with special attention devoted to potential interferences and their control. Chloride interference, which is due to the formation of the volatile monochloride in the condensed phase, is the most frequently observed problem. Due to its high dissociation energy (88 kcal/mol), TlCl is difficult to dissociate in the gas phase and is easily lost. The best means of controlling this interference in ETA is atomization under isothermal conditions according to the stabilized temperature platform furnace concept, and the use of reduced palladium as a modifier. An alternative approach appears to be the 'fast furnace' concept, wherein both the use of a modifier and the pyrolysis stage are omitted. This concept requires an efficient background correction system, and high-resolution continuum-source atomic absorption spectrometry (HR-CS AAS) appears to offer the best results. This chloride interference can also cause significant problems when ETV techniques are used. Among the spectral interferences found in the determination of thallium are those due to Pd, the most efficient modifier, and Fe, which is frequently found at high concentrations in environmental samples. Both interferences are due to nearby atomic lines, and are observed only when deuterium background correction and relatively high atomization temperatures are used. A more serious spectral interference is that due to the molecular absorption spectrum of SO 2, which has a maximum around the Tl line and exhibits a pronounced rotational fine structure. HR-CS AAS again showed the best performance in coping with this interference.

  11. Wind Tunnel Interference on Wings, Bodies and Airscrews

    DTIC Science & Technology

    1933-09-13

    jet usually issues from a eliminated by designing tie wiand tunnel with a slight expanson closed cylindrical mouth immediately in front of the model...pressilre at the boundary. This type of constraiA 16 \\1 h 3/. would occur under the ideal conditions of a perfect fluid, and it is I Eperimental confirmation

  12. Processing fissile material mixtures containing zirconium and/or carbon

    DOEpatents

    Johnson, Michael Ernest; Maloney, Martin David

    2013-07-02

    A method of processing spent TRIZO-coated nuclear fuel may include adding fluoride to complex zirconium present in a dissolved TRIZO-coated fuel. Complexing the zirconium with fluoride may reduce or eliminate the potential for zirconium to interfere with the extraction of uranium and/or transuranics from fission materials in the spent nuclear fuel.

  13. Basin F Overburden and Soil Sampling and Analysis Study, Rocky Mountain Arsenal

    DTIC Science & Technology

    1982-05-01

    boring sites will be es:ablished via standard :and surveyinS procedures. 3.3 Bor-ng/ Samaling Procidures Upon staking/marking of the bore holes, the folloi...procedure until the interferences have been eliminated. 3.2.2 Samale Testing Step OC (6) (Procedure Blank) The procedure blank consists of the

  14. Interspecific competition between Solenopsis invicta and two native ant species, Pheidole fervens and Monomorium chinense.

    PubMed

    Chen, Yin-Cheng; Kafle, Lekhnath; Shih, Cheng-Jen

    2011-04-01

    This study was designed to understand the effects of the interspecific competition between red imported fire ant, Solenopsis invicta Buren and two native ant species, Pheidole fervens Smith and Monomorium chinense Santschi, by conducting colony interference and individual confrontation tests under laboratory conditions. The colony interference test showed that both native ant species, owing to their numerical advantage, killed the Solenopsis invicta virus-1 (SINV-1)-infected or healthy queens of S. invicta. Significantly less time was required for M. chinense to kill all SINV-1-infected S. invicta compared with the time required to kill the healthy S. invicta. Compared with healthy S. invicta, SINV-1-infected S. invicta spent a longer time eliminating the P. fervens colonies. In confrontation tests, M. chinense killed a significantly higher number of infected S. invicta minors than they did healthy minors, but the number of S. invicta majors (either infected or healthy) killed was substantially less. This study found that the viral infection weakened the competitive ability of S. invicta and made them prone to be eliminated by M. chinense but not by P. fervens.

  15. Multiview point clouds denoising based on interference elimination

    NASA Astrophysics Data System (ADS)

    Hu, Yang; Wu, Qian; Wang, Le; Jiang, Huanyu

    2018-03-01

    Newly emerging low-cost depth sensors offer huge potentials for three-dimensional (3-D) modeling, but existing high noise restricts these sensors from obtaining accurate results. Thus, we proposed a method for denoising registered multiview point clouds with high noise to solve that problem. The proposed method is aimed at fully using redundant information to eliminate the interferences among point clouds of different views based on an iterative procedure. In each iteration, noisy points are either deleted or moved to their weighted average targets in accordance with two cases. Simulated data and practical data captured by a Kinect v2 sensor were tested in experiments qualitatively and quantitatively. Results showed that the proposed method can effectively reduce noise and recover local features from highly noisy multiview point clouds with good robustness, compared to truncated signed distance function and moving least squares (MLS). Moreover, the resulting low-noise point clouds can be further smoothed by the MLS to achieve improved results. This study provides the feasibility of obtaining fine 3-D models with high-noise devices, especially for depth sensors, such as Kinect.

  16. Structural health monitoring using DOG multi-scale space: an approach for analyzing damage characteristics

    NASA Astrophysics Data System (ADS)

    Guo, Tian; Xu, Zili

    2018-03-01

    Measurement noise is inevitable in practice; thus, it is difficult to identify defects, cracks or damage in a structure while suppressing noise simultaneously. In this work, a novel method is introduced to detect multiple damage in noisy environments. Based on multi-scale space analysis for discrete signals, a method for extracting damage characteristics from the measured displacement mode shape is illustrated. Moreover, the proposed method incorporates a data fusion algorithm to further eliminate measurement noise-based interference. The effectiveness of the method is verified by numerical and experimental methods applied to different structural types. The results demonstrate that there are two advantages to the proposed method. First, damage features are extracted by the difference of the multi-scale representation; this step is taken such that the interference of noise amplification can be avoided. Second, a data fusion technique applied to the proposed method provides a global decision, which retains the damage features while maximally eliminating the uncertainty. Monte Carlo simulations are utilized to validate that the proposed method has a higher accuracy in damage detection.

  17. Triethylamine-assisted Mg(OH)2 coprecipitation/preconcentration for determination of trace metals and rare earth elements in seawater by inductively coupled plasma mass spectrometry (ICP-MS).

    PubMed

    Arslan, Zikri; Oymak, Tulay; White, Jeremy

    2018-05-30

    In this paper, we report an improved magnesium hydroxide, Mg(OH) 2 , coprecipitation method for the determination of 16 trace elements (Al, V, Cr, Mn, Mn, Fe, Co, Ni, Cu, Zn, Ga, As, Se, Sb, Sn and Pb) and 18 rare earth elements (REEs), including Sc, Y, U and Th in seawater and estuarine water samples. The procedure involves coprecipitation of the trace elements and REEs on Mg(OH) 2 upon addition of a small volume of triethylamine (TEA) followed by analysis of the dissolved pellet solutions by inductively coupled plasma mass spectrometry (ICP-MS). Three-step sequential coprecipitation was carried out on 10 mL aliquots of seawater to eliminate the matrix ions and to preconcentrate the analytes of interest into a 1 mL final volume. Spike recoveries varied from 85% (Th) to 105% (Y). Calcium (Ca), sodium (Na) and potassium (K) matrices were virtually eliminated from the analysis solutions. Collision reaction interface (CRI) technology utilizing H 2 and He gases was employed to determine its effectiveness in removing the spectral interferences originating from the residual Mg matrix, TEA and plasma gases. H 2 was more effective than He in reducing spectral interferences from TEA and plasma gases. Limits of detection (LODs) ranged from 0.01 ng L -1 (Ho) to 72 ng L -1  (Al). The method was validated by using certified seawater (CASS-4) and estuarine water (SLEW-3) reference materials. Precision for five (n = 5) replicate measurements were between 1.2% (Pr) and 18% (Lu). Fe, Pb, Sn, and Zn impurities in TEA were significant in comparison to the levels in CASS-4 and SLEW-3, while relatively high background signals impacted determinations of low levels of Sc and Th. The effects of these hurdles on precision and accuracy were alleviated by measuring these elements in spiked CASS-4 and SLEW-3. Copyright © 2018 Elsevier B.V. All rights reserved.

  18. Photometer for detection of sodium day airglow.

    NASA Technical Reports Server (NTRS)

    Mcmahon, D. J.; Manring, E. R.; Patty, R. R.

    1973-01-01

    Description of a photometer for daytime ground-based measurements of sodium airglow emission. The photometer described can be characterized by the following principal features: (1) a narrow (4.5-A) interference filter for initial discrimination; (2) cooled photomultiplier detector to reduce noise from dark current fluctuations and chopping to eliminate the average dark current; (3) a sodium vapor resonance cell to provide an effective bandpass comparable to the Doppler line width; (4) separate detection of all light transmitted by the interference filter to evaluate the Rayleigh and Mie components within the Doppler width of the resonance cell; and (5) temperature quenching of the resonance cell to evaluate and account for instrumental imperfections.

  19. Targeted Elimination of Peroxisomes During Viral Infection: Lessons from HIV and Other Viruses.

    PubMed

    Wong, Cheung Pang; Xu, Zaikun; Power, Christopher; Hobman, Tom C

    2018-05-01

    Peroxisomes are membrane-bound organelles that are best known for their roles in lipid metabolism. Mounting evidence indicates that they are also important nodes for antiviral signaling. While research over the past few decades has revealed effective viral strategies to block antiviral signalling pathways from the plasma membrane, mitochondria and/or the nucleus, until recently, very little was known about how viruses interfere with peroxisome-based antiviral signaling. In this essay, we review how viruses use a variety of strategies to interfere with peroxisome biogenesis, a phenomenon that has implications for evasion of the host immune system as well as pathogenesis.

  20. Zadoff-Chu sequence-based hitless ranging scheme for OFDMA-PON configured 5G fronthaul uplinks

    NASA Astrophysics Data System (ADS)

    Reza, Ahmed Galib; Rhee, June-Koo Kevin

    2017-05-01

    A Zadoff-Chu (ZC) sequence-based low-complexity hitless upstream time synchronization scheme is proposed for an orthogonal frequency division multiple access passive optical network configured cloud radio access network fronthaul. The algorithm is based on gradual loading of the ZC sequences, where the phase discontinuity due to the cyclic prefix is alleviated by a frequency domain phase precoder, eliminating the requirements of guard bands to mitigate intersymbol interference and inter-carrier interference. Simulation results for uncontrolled-wavelength asynchronous transmissions from four concurrent transmitting optical network units are presented to demonstrate the effectiveness of the proposed scheme.

  1. A Multipath Mitigation Algorithm for vehicle with Smart Antenna

    NASA Astrophysics Data System (ADS)

    Ji, Jing; Zhang, Jiantong; Chen, Wei; Su, Deliang

    2018-01-01

    In this paper, the antenna array adaptive method is used to eliminate the multipath interference in the environment of GPS L1 frequency. Combined with the power inversion (PI) algorithm and the minimum variance no distortion response (MVDR) algorithm, the anti-Simulation and verification of the antenna array, and the program into the FPGA, the actual test on the CBD road, the theoretical analysis of the LCMV criteria and PI and MVDR algorithm principles and characteristics of MVDR algorithm to verify anti-multipath interference performance is better than PI algorithm, The satellite navigation in the field of vehicle engineering practice has some guidance and reference.

  2. Photonic-based liquid level transmitter using Mach-Zehnder interferometer for industrial application

    NASA Astrophysics Data System (ADS)

    Singh, Yadvendra; Raghuwanshi, Sanjeev K.; Kumar, Manish

    2018-02-01

    In the present scenario the process control industries mainly uses 1-5 Volt or 4-20 mA protocol for transmitting the measured signal to remote location operators. These types of protocol prone to interference and limited data transfer rate. To overcome these types of limitation we proposed photonic based transmitter for liquid level measurement which will enhance data transfer rate and interference reduction to eliminate noise signal in the channel during transmission to make transmission more reliable, accurate and consistent in performance. The required mathematical derivation and the principle of operation of the transmitter are shown in the paper.

  3. Experimental evaluation of blockage ratio and plenum evacuation system flow effects on pressure distribution for bodies of revolution in 0.1 scale model test section of NASA Lewis Research Center's proposed altitude wind tunnel

    NASA Technical Reports Server (NTRS)

    Burley, Richard R.; Harrington, Douglas E.

    1987-01-01

    An experimental investigation was conducted in the slotted test section of the 0.1-scale model of the proposed Altitude Wind Tunnel to evaluate wall interference effects at tunnel Mach numbers from 0.70 to 0.95 on bodies of revolution with blockage rates of 0.43, 3, 6, and 12 percent. The amount of flow that had to be removed from the plenum chamber (which surrounded the slotted test section) by the plenum evacuation system (PES) to eliminate wall interference effects was determined. The effectiveness of tunnel reentry flaps in removing flow from the plenum chamber was examined. The 0.43-percent blockage model was the only one free of wall interference effects with no PES flow. Surface pressures on the forward part of the other models were greater than interference-free results and were not influenced by PES flow. Interference-free results were achieved on the aft part of the 3- and 6-percent blockage models with the proper amount of PES flow. The required PES flow was substantially reduced by opening the reentry flaps.

  4. A New Reassigned Spectrogram Method in Interference Detection for GNSS Receivers.

    PubMed

    Sun, Kewen; Jin, Tian; Yang, Dongkai

    2015-09-02

    Interference detection is very important for Global Navigation Satellite System (GNSS) receivers. Current work on interference detection in GNSS receivers has mainly focused on time-frequency (TF) analysis techniques, such as spectrogram and Wigner-Ville distribution (WVD), where the spectrogram approach presents the TF resolution trade-off problem, since the analysis window is used, and the WVD method suffers from the very serious cross-term problem, due to its quadratic TF distribution nature. In order to solve the cross-term problem and to preserve good TF resolution in the TF plane at the same time, in this paper, a new TF distribution by using a reassigned spectrogram has been proposed in interference detection for GNSS receivers. This proposed reassigned spectrogram method efficiently combines the elimination of the cross-term provided by the spectrogram itself according to its inherent nature and the improvement of the TF aggregation property achieved by the reassignment method. Moreover, a notch filter has been adopted in interference mitigation for GNSS receivers, where receiver operating characteristics (ROCs) are used as metrics for the characterization of interference mitigation performance. The proposed interference detection method by using a reassigned spectrogram is evaluated by experiments on GPS L1 signals in the disturbing scenarios in comparison to the state-of-the-art TF analysis approaches. The analysis results show that the proposed interference detection technique effectively overcomes the cross-term problem and also keeps good TF localization properties, which has been proven to be valid and effective to enhance the interference Sensors 2015, 15 22168 detection performance; in addition, the adoption of the notch filter in interference mitigation has shown a significant acquisition performance improvement in terms of ROC curves for GNSS receivers in jamming environments.

  5. A New Reassigned Spectrogram Method in Interference Detection for GNSS Receivers

    PubMed Central

    Sun, Kewen; Jin, Tian; Yang, Dongkai

    2015-01-01

    Interference detection is very important for Global Navigation Satellite System (GNSS) receivers. Current work on interference detection in GNSS receivers has mainly focused on time-frequency (TF) analysis techniques, such as spectrogram and Wigner–Ville distribution (WVD), where the spectrogram approach presents the TF resolution trade-off problem, since the analysis window is used, and the WVD method suffers from the very serious cross-term problem, due to its quadratic TF distribution nature. In order to solve the cross-term problem and to preserve good TF resolution in the TF plane at the same time, in this paper, a new TF distribution by using a reassigned spectrogram has been proposed in interference detection for GNSS receivers. This proposed reassigned spectrogram method efficiently combines the elimination of the cross-term provided by the spectrogram itself according to its inherent nature and the improvement of the TF aggregation property achieved by the reassignment method. Moreover, a notch filter has been adopted in interference mitigation for GNSS receivers, where receiver operating characteristics (ROCs) are used as metrics for the characterization of interference mitigation performance. The proposed interference detection method by using a reassigned spectrogram is evaluated by experiments on GPS L1 signals in the disturbing scenarios in comparison to the state-of-the-art TF analysis approaches. The analysis results show that the proposed interference detection technique effectively overcomes the cross-term problem and also keeps good TF localization properties, which has been proven to be valid and effective to enhance the interference detection performance; in addition, the adoption of the notch filter in interference mitigation has shown a significant acquisition performance improvement in terms of ROC curves for GNSS receivers in jamming environments. PMID:26364637

  6. Conversion of umbilical arterial Doppler waveforms to cardiac cycle triggering signals: a preparatory study for online motion-gated three-dimensional fetal echocardiography.

    PubMed

    Deng, J; Birkett, A G; Kalache, K D; Hanson, M A; Peebles, D M; Linney, A D; Lees, W R; Rodeck, C H

    2001-01-01

    To remove motion artefacts, a device was built to convert "noisy" umbilical arterial Doppler waveforms (UADWs) from an ultrasound (US) system into sharp ECG R-wave-like cardiac cycle triggering signals (CCTSs). These CCTSs were then used to gate a simultaneous (online) 3-D acquisition of sectional fetal echocardiograms from another US system. To test the conversion performance, a study was carried out in sheep fetal twins. Pulmonary arterial flow waveforms (PAFWs) from implanted probes were traced, in the meantime, to determine the reference cardiac cycle. Interference caused by running the two nonsynchronised US systems was controlled to three degrees (not-noticeable, moderate, and severe), together with high (> or = 40 cm/s) and low (< 40) flow velocities on UADWs. The conversion efficiency, assessed by the percentage of UADWs converted into CCTSs, was in the range of 83% to 100% for not-noticeable and moderate interference, and 0% to 71% for severe interference. The triggering accuracy, assessed by [(time lag mean between the onsets of PAFWs and corresponding CCTSs) -- (its 99% confidence level)] / the mean, was 90% to 96% for the not-noticeable interference high- and low-flow groups and for the moderate interference high-flow group; 19% to 93% for the moderate interference low-flow group; and from not obtainable up to 90% for the severe interference groups. The results show that UADWs can be used as a satisfactory online motion-gating source even in the presence of moderate interference. The major problems are from severe interference or moderate interference with low-flow velocity, which can be minimised/eliminated by the integration of the individual systems involved.

  7. Matter-wave coherence limit owing to cosmic gravitational wave background

    NASA Astrophysics Data System (ADS)

    Steane, Andrew M.

    2017-12-01

    We study matter-wave interferometry in the presence of a stochastic background of gravitational waves. It is shown that if the background has a scale-invariant spectrum over a wide bandwidth (which is expected in a class of inflationary models of Big Bang cosmology), then separated-path interference cannot be observed for a lump of matter of size above a limit which is very insensitive to the strength and bandwidth of the fluctuations, unless the interferometer is servo-controlled or otherwise protected. For ordinary solid matter this limit is of order 1-10 mm. A servo-controlled or cross-correlated device would also exhibit limits to the observation of macroscopic interference, which we estimate for ordinary matter moving at speeds small compared to c.

  8. Social priming of dyslexia and reduction of the Stroop effect: what component of the Stroop effect is actually reduced?

    PubMed

    Augustinova, Maria; Ferrand, Ludovic

    2014-03-01

    Recently, Goldfarb, Aisenberg, and Henik (2011) showed that in a manual format of the Stroop task, dyslexia priming eliminates the normal magnitude of the interference-based Stroop-like findings otherwise exhibited by individuals participating in such research. Goldfarb et al. (2011) consequently concluded that the effect of word reading in a Stroop task (i.e., one automatic behavior) can be effectively controlled through an automatic instruction "do not read" (i.e., another automatic behavior). The present study further investigated these ideas by examining when and how dyslexia priming controls different processes involved in a Stroop task. To this end, the original finding was first replicated (Experiment 1) and subsequently extended to the vocal (instead of manual) response modality to examine whether previously reported eliminations of the Stroop effect persist with this response format (i.e., format producing larger Stroop effects). Since past work (e.g., Augustinova & Ferrand, 2012a; Brown, Joneleit et al., 2002; Ferrand & Augustinova, 2013) had suggested that various interventions were likely to reduce (rather than eliminate) the interference-based Stroop-like findings with vocal responses, a further aim of these experiments was to identify the component of these findings that dyslexia priming actually reduces. To this end, the effects of this intervention were examined in a more fine-grained variant of the Stroop task that distinguished between interference resulting from task-irrelevant processes involved in computing the lexical and semantic representations of the word (i.e., a written distractor to ignore) and task-relevant processes involved in the selection of a response (i.e., a color target to name) that are both involved in this task. In line with our past work (e.g., Augustinova & Ferrand, 2012a; Ferrand & Augustinova, 2013), the results of two experiments (Experiments 2 and 3) showed that in the vocal format, dyslexia priming reduces but does not eliminate the normal magnitude of the interference-based Stroop-like findings and that this reduction is solely due to the control of processes involved in the selection of a response (i.e., a color target to name) - processes that are known to be controllable in this format (Ferrand & Augustinova, 2013). Given that in this format, dyslexia priming had no effect on task-irrelevant processes involved in computing the lexical and semantic representations of a written distractor to be ignored - processes that are known to be automatic - further implications for the control of automatic processes via dyslexia priming are considered and an interpretation in terms of a unitary control mechanism for both the manual and vocal formats is proposed. Copyright © 2013 Elsevier B.V. All rights reserved.

  9. [Determination of heavy metals for RoHS compliance by ICP-OES spectrometry coupled with microwave extraction system].

    PubMed

    Hua, Li; Wu, Yi-Ping; An, Bing; Lai, Xiao-Wei

    2008-11-01

    The harm of heavy metals contained in electronic and electrical equipment (EEE) on environment is of high concern by human. Aiming to handle the great challenge of RoHS compliance, the determinations of trace or ultratrace chromium (Cr), cadmium (Cd), mercury (Hg) and lead (Pb) by inductively coupled plasma optical emission spectrometry (ICP-OES) was performed in the present paper, wherein, microwave extraction technology was used to prepare the sample solutions. In addition, the precision, recovery, repeatability and interference issues of this method were also discussed. The results exhibited that using the microwave extraction system to prepare samples is more quick, lossless, contamination-free in comparison with the conventional extraction methods such as dry ashing, wet-oven extraction etc. By analyzing the recoveries of these four heavy metals over different working time and wavelengths, the good recovery range between 85% and 115% showed that there was only tiny loss or contamination during the process of microwave extraction, sample introduction and ICP detection. Repeatability experiments proved that ICP plasma had a good stability during the working time and the matrix effect was small. Interference was a problem troublesome for atomic absorption spectrometry (AAS), however, the techniques of standard additions or inter-element correction (IEC) method can effectively eliminated the interferences of Ni, As, Fe etc. with the Cd determination. By employing the multi-wavelengths and two correction point methods, the issues of background curve sloping shift and spectra overlap were successfully overcome. Besides, for the determinations of trace heavy metal elements, the relative standard deviation (RSD) was less than 3% and the detection limits were less than 1 microg x L(-10 (3sigma, n = 5) for samples, standard solutions, and standard additions, which proved that ICP-OES has a good precision and high reliability. This provided a reliable technique support for electronic and electrical (EE) industries to comply with RoHS directive.

  10. Analysis of OFDMA receiver with carrier frequency offset and common carrier frequency offset (CCFO)

    NASA Astrophysics Data System (ADS)

    Gauni, Sabitha; Kumar, R.

    2013-01-01

    The technique of Orthogonal frequency multiplexing (OFDM) is used to mitigate the multipath effects and to achieve better data rate. When these systems are extended to enable multiple access wireless multimedia communications they are more beneficial. The performance of the OFDM systems degrades with frequency offset and phase offset. The OFDM multiple access (OFDMA) technology allots groups of the OFDM subcarriers allocated to different users for transmission. In this paper we study the interference effects of the individual subcarriers with the neighbouring subcarriers which also plays a role in the system degradation is termed as Multiuser Interference (MUI). The effect of Carrier frequency offset (CFO) on these systems is also taken in account. There are conventional CFO compensation methods for OFDMA systems the CFOs are usually compensated by directly eliminating the intercarrier interference (ICI) caused by the residual CFOs for individual users.

  11. THE DETERMINATION OF TRACES OF BORON IN ZIRCONIUM METAL AND ZIRCONIUM ALLOYS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hayes, M.R.; Metcalfe, J.

    1962-01-01

    A general procedure is given for the determination of B, down to 0.2 ppm, in Zr and Zr alloys. Separation of the B is not necessary, the B-curcumin complex being formed directly in an aliquot of the metal sulfate solution. An interference effect has been noted when analyzing Zr alloys containing Sn. The interference is caused by an insoluble compound of curcumin which separates and has similar properties to the B-curcumin complex. This source of interference is, however, readily eliminated during the procedure for the determination of B. The procedure has been applied to the determination of B in puremore » Zr, zr--0.5% Cu-- 0.5% MO, and Zr--1.5% Sn--0.1% Fe--0.1% Cr--0.05% Ni alloys. Results are comparable with those obtained by methods requiring the separation of the B as methyl borate. (auth)« less

  12. Arsenic species analysis in porewaters and sediments using hydride generation atomic fluorescence spectrometry.

    PubMed

    Liao, Meng-xia; Deng, Tian-long

    2006-01-01

    It was observed that the atomic fluorescence emission due to As(V) could has a 10% to 40% of fluorescence emission signal during the determination of As(III) in the mixture of As(III) and As(V). Besides, interferes from heavy metals such as Pb(lIl), Cu(ll) can cause severe increase of the signals as compared to the insignificant effects caused by Cd(II), Zn(ll), Mn(II) and Fe(Ill). On the basis of further studies, the masking agent of 8-hydroxyquinoline was used as an efficient agent to eliminate interference of As(V) emission and the heavy metal of Cu2+ and Pb2+ in the measurements of arsenic species. After a series standard additions and CRM researches, a sensitive and interference-free analytical procedure was developed for the speciation of arsenic in samples of porewaters and sediments in Poyang Lake, China.

  13. A methodology to enhance electromagnetic compatibility in joint military operations

    NASA Astrophysics Data System (ADS)

    Buckellew, William R.

    The development and validation of an improved methodology to identify, characterize, and prioritize potential joint EMI (electromagnetic interference) interactions and identify and develop solutions to reduce the effects of the interference are discussed. The methodology identifies potential EMI problems using results from field operations, historical data bases, and analytical modeling. Operational expertise, engineering analysis, and testing are used to characterize and prioritize the potential EMI problems. Results can be used to resolve potential EMI during the development and acquisition of new systems and to develop engineering fixes and operational workarounds for systems already employed. The analytic modeling portion of the methodology is a predictive process that uses progressive refinement of the analysis and the operational electronic environment to eliminate noninterfering equipment pairs, defer further analysis on pairs lacking operational significance, and resolve the remaining EMI problems. Tests are conducted on equipment pairs to ensure that the analytical models provide a realistic description of the predicted interference.

  14. Examination of in vivo tear film stability after eye blink and eye drying

    NASA Astrophysics Data System (ADS)

    Szczesna, Dorota H.; Kulas, Zbigniew; Kasprzak, Henryk T.; Stenevi, Ulf

    2007-07-01

    The purpose of this study is to investigate the kinetics of precorneal tear film stabilization process after eye blink and the process of creating the break-up of the tear film layer. The tear film of patients were examined in vivo by used the lateral shearing interferometer. The information about the distribution and stability of the tear film over the cornea is carried by the wave front reflected from the surface of tears and coded in interference fringes. Smooth and regular fringes indicate the smooth surface of tears over the cornea. Immediately after eye blink the interference fringes are observed on background of bright and dark areas. The contrast of this structure fades with time slowly and after 1-3 sec the background of interference fringes becomes uniform. The vertical orientation and instability of this structure suggests connection with eyelid movement and the spread of tears. If the eye is kept open for a long time, bright lines appear in the background of fringes after a dozen seconds. The slowly appearing structure might signify the tear film break-up. In case of eyes after a LASIK surgery the shape of the background structure has different nature and might be stable in time suggesting the stability of the corneal surface irregularities.

  15. Sample processing approach for detection of ricin in surface samples.

    PubMed

    Kane, Staci; Shah, Sanjiv; Erler, Anne Marie; Alfaro, Teneile

    2017-12-01

    With several ricin contamination incidents reported over the past decade, rapid and accurate methods are needed for environmental sample analysis, especially after decontamination. A sample processing method was developed for common surface sampling devices to improve the limit of detection and avoid false negative/positive results for ricin analysis. Potential assay interferents from the sample matrix (bleach residue, sample material, wetting buffer), including reference dust, were tested using a Time-Resolved Fluorescence (TRF) immunoassay. Test results suggested that the sample matrix did not cause the elevated background fluorescence sometimes observed when analyzing post-bleach decontamination samples from ricin incidents. Furthermore, sample particulates (80mg/mL Arizona Test Dust) did not enhance background fluorescence or interfere with ricin detection by TRF. These results suggested that high background fluorescence in this immunoassay could be due to labeled antibody quality and/or quantity issues. Centrifugal ultrafiltration devices were evaluated for ricin concentration as a part of sample processing. Up to 30-fold concentration of ricin was observed by the devices, which serve to remove soluble interferents and could function as the front-end sample processing step to other ricin analytical methods. The procedure has the potential to be used with a broader range of environmental sample types and with other potential interferences and to be followed by other ricin analytical methods, although additional verification studies would be required. Published by Elsevier B.V.

  16. Sodium Chloride Crystal-Induced SERS Platform for Controlled Highly Sensitive Detection of Illicit Drugs.

    PubMed

    Yu, Borong; Li, Pan; Zhou, Binbin; Tang, Xianghu; Li, Shaofei; Yang, Liangbao

    2018-04-03

    A sodium chloride crystal-driven spontaneous 'hot spot' structure was demonstrated as a SERS-active platform, to get reproducible SERS signals, and eliminate the need for mapping large areas, in comparison with solution phase testing. During the process of solvent evaporation, the crystals produced induced silver aggregates to assemble around themselves. The micro-scale crystals can also act as a template to obtain an optical position, such that the assembled hot area is conveniently located during SERS measurements. More importantly, the chloride ions added in colloids can also replace the citrate and on the surface of the silver sol, and further decrease the background interference. High quality SERS spectra from heroin, methamphetamine (MAMP), and cocaine have been obtained on the crystal-driven hot spot structure with high sensitivity and credible reproducibility. This approach can not only bring the nanoparticles to form plasmonic hot spots in a controlled way, and thus provide high sensitivity, but also potentially be explored as an active substrate for label-free detection of other illicit drugs or additives. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Cytotoxicity screening of 23 engineered nanomaterials using a test matrix of ten cell lines and three different assays

    PubMed Central

    2011-01-01

    Background Engineered nanomaterials display unique properties that may have impact on human health, and thus require a reliable evaluation of their potential toxicity. Here, we performed a standardized in vitro screening of 23 engineered nanomaterials. We thoroughly characterized the physicochemical properties of the nanomaterials and adapted three classical in vitro toxicity assays to eliminate nanomaterial interference. Nanomaterial toxicity was assessed in ten representative cell lines. Results Six nanomaterials induced oxidative cell stress while only a single nanomaterial reduced cellular metabolic activity and none of the particles affected cell viability. Results from heterogeneous and chemically identical particles suggested that surface chemistry, surface coating and chemical composition are likely determinants of nanomaterial toxicity. Individual cell lines differed significantly in their response, dependent on the particle type and the toxicity endpoint measured. Conclusion In vitro toxicity of the analyzed engineered nanomaterials cannot be attributed to a defined physicochemical property. Therefore, the accurate identification of nanomaterial cytotoxicity requires a matrix based on a set of sensitive cell lines and in vitro assays measuring different cytotoxicity endpoints. PMID:21345205

  18. High-contrast fluorescence imaging based on the polarization dependence of the fluorescence enhancement using an optical interference mirror slide.

    PubMed

    Yasuda, Mitsuru; Akimoto, Takuo

    2015-01-01

    High-contrast fluorescence imaging using an optical interference mirror (OIM) slide that enhances the fluorescence from a fluorophore located on top of the OIM surface is reported. To enhance the fluorescence and reduce the background light of the OIM, transverse-electric-polarized excitation light was used as incident light, and the transverse-magnetic-polarized fluorescence signal was detected. As a result, an approximate 100-fold improvement in the signal-to-noise ratio was achieved through a 13-fold enhancement of the fluorescence signal and an 8-fold reduction of the background light.

  19. JPRS Report, East Europe.

    DTIC Science & Technology

    1988-05-25

    eliminated from economic life by every means for entire decades. Therefore, a decisive majority of decisionmakers and manufacturers must learn it nearly...Administrative Reforms Explained 21 Political, Economic Needs Interfere With Nomenklatura Practices 22 Kalisz, Stavropol TU’s, Industries Cooperation Noted...24 Enterprises Criticized for Not Controlling Wage Increases 24 PZPR Voivodship Plenum Views Unemployment, Production Levels 25 Economic System

  20. 46 CFR 173.085 - General subdivision requirements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... elimination of the required inner bottom is allowed if— (1) The inner bottom would interfere with the mission.... (k) Each port light in a space located below the freeboard deck, as defined in § 42.13-15(i) of this chapter, or in a space within an enclosed superstructure must be fitted with a hinged inside dead cover...

  1. 46 CFR 173.085 - General subdivision requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... elimination of the required inner bottom is allowed if— (1) The inner bottom would interfere with the mission.... (k) Each port light in a space located below the freeboard deck, as defined in § 42.13-15(i) of this chapter, or in a space within an enclosed superstructure must be fitted with a hinged inside dead cover...

  2. 46 CFR 173.085 - General subdivision requirements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... elimination of the required inner bottom is allowed if— (1) The inner bottom would interfere with the mission.... (k) Each port light in a space located below the freeboard deck, as defined in § 42.13-15(i) of this chapter, or in a space within an enclosed superstructure must be fitted with a hinged inside dead cover...

  3. 46 CFR 173.085 - General subdivision requirements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... elimination of the required inner bottom is allowed if— (1) The inner bottom would interfere with the mission.... (k) Each port light in a space located below the freeboard deck, as defined in § 42.13-15(i) of this chapter, or in a space within an enclosed superstructure must be fitted with a hinged inside dead cover...

  4. 46 CFR 173.085 - General subdivision requirements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... elimination of the required inner bottom is allowed if— (1) The inner bottom would interfere with the mission.... (k) Each port light in a space located below the freeboard deck, as defined in § 42.13-15(i) of this chapter, or in a space within an enclosed superstructure must be fitted with a hinged inside dead cover...

  5. Skin-Friction Measurements at Subsonic and Transonic Mach Numbers with Embedded-Wire Gages

    DTIC Science & Technology

    1981-01-01

    Model ................................... 17 9. Boundary-Layer Rake Installation on EBOR Model...boundary-layer total pressure rake eliminates this bulky mechanism and the long data acquisition time, but it introduces interferences which affect the...its construction. Further, boundary-layer rakes are restricted to measurements in thick boundary layers. Surface pressure probes such as Stanton tubes

  6. Characterization and elimination of undesirable protein residues in plant cell walls for enhancing lignin analysis by solution-state 2D gel-NMR methods

    USDA-ARS?s Scientific Manuscript database

    Proteins exist in every plant cell wall. Certain protein residues interfere with lignin characterization and quantification. The current solution-state 2D-NMR technique (gel-NMR) for whole plant cell wall structural profiling provides detailed information regarding cell walls and proteins. However, ...

  7. 47 CFR 74.861 - Technical requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... prescribed in paragraphs (c) through (e) of this section. (c) Low power auxiliary transmitters not required... bands—50 mW (ii) 470-608 and 614-698 MHz bands—250 mW (2) Transmitters may be either crystal controlled... eliminate the interference. (Sec. 5, 48 Stat. 1068; 47 U.S.C. 155) [43 FR 13576, Mar. 31, 1978, as amended...

  8. A Novel Transient Fault Current Sensor Based on the PCB Rogowski Coil for Overhead Transmission Lines

    PubMed Central

    Liu, Yadong; Xie, Xiaolei; Hu, Yue; Qian, Yong; Sheng, Gehao; Jiang, Xiuchen

    2016-01-01

    The accurate detection of high-frequency transient fault currents in overhead transmission lines is the basis of malfunction detection and diagnosis. This paper proposes a novel differential winding printed circuit board (PCB) Rogowski coil for the detection of transient fault currents in overhead transmission lines. The interference mechanism of the sensor surrounding the overhead transmission line is analyzed and the guideline for the interference elimination is obtained, and then a differential winding printed circuit board (PCB) Rogowski coil is proposed, where the branch and return line of the PCB coil were designed to be strictly symmetrical by using a joining structure of two semi-rings and collinear twisted pair differential windings in each semi-ring. A serial test is conducted, including the frequency response, linearity, and anti-interference performance as well as a comparison with commercial sensors. Results show that a PCB Rogowski coil has good linearity and resistance to various external magnetic field interferences, thus enabling it to be widely applied in fault-current-collecting devices. PMID:27213402

  9. Inhibition of vemurafenib-resistant melanoma by interference with pre-mRNA splicing

    PubMed Central

    Salton, Maayan; Kasprzak, Wojciech K.; Voss, Ty; Shapiro, Bruce A.; Poulikakos, Poulikos I.; Misteli, Tom

    2015-01-01

    Mutations in the serine/threonine kinase BRAF are found in more than 60% of melanomas. The most prevalent melanoma mutation is BRAF(V600E), which constitutively activates downstream MAPK signaling. Vemurafenib is a potent RAF kinase inhibitor with remarkable clinical activity in BRAF(V600E)-positive melanoma tumors. However, patients rapidly develop resistance to vemurafenib treatment. One resistance mechanism is the emergence of BRAF alternative splicing isoforms leading to elimination of the RAS-binding domain. Here we identify interference with pre-mRNA splicing as a mechanism to combat vemurafenib resistance. We find that small molecule pre-mRNA splicing modulators reduce BRAF3-9 production and limit in-vitro cell growth of vemurafenib-resistant cells. In xenograft models, interference with pre-mRNA splicing prevents tumor formation and slows growth of vemurafenib-resistant tumors. Our results identify an intronic mutation as a molecular basis for RNA splicing-mediated RAF inhibitor resistance and we identify pre-mRNA splicing interference as a potential therapeutic strategy for drug resistance in BRAF melanoma. PMID:25971842

  10. Inhibition of vemurafenib-resistant melanoma by interference with pre-mRNA splicing.

    PubMed

    Salton, Maayan; Kasprzak, Wojciech K; Voss, Ty; Shapiro, Bruce A; Poulikakos, Poulikos I; Misteli, Tom

    2015-05-14

    Mutations in the serine/threonine kinase BRAF are found in more than 60% of melanomas. The most prevalent melanoma mutation is BRAF(V600E), which constitutively activates downstream MAPK signalling. Vemurafenib is a potent RAF kinase inhibitor with remarkable clinical activity in BRAF(V600E)-positive melanoma tumours. However, patients rapidly develop resistance to vemurafenib treatment. One resistance mechanism is the emergence of BRAF alternative splicing isoforms leading to elimination of the RAS-binding domain. Here we identify interference with pre-mRNA splicing as a mechanism to combat vemurafenib resistance. We find that small-molecule pre-mRNA splicing modulators reduce BRAF3-9 production and limit in-vitro cell growth of vemurafenib-resistant cells. In xenograft models, interference with pre-mRNA splicing prevents tumour formation and slows growth of vemurafenib-resistant tumours. Our results identify an intronic mutation as the molecular basis for a RNA splicing-mediated RAF inhibitor resistance mechanism and we identify pre-mRNA splicing interference as a potential therapeutic strategy for drug resistance in BRAF melanoma.

  11. The Intention Interference Effect: The Difficulty of Ignoring What You Intend to Do

    PubMed Central

    Cohen, Anna-Lisa; Kantner, Justin; Dixon, Roger A.; Lindsay, D. Stephen

    2013-01-01

    Intentions have been shown to be more accessible (e.g., more quickly and accurately recalled) compared to other sorts of to-be-remembered information; a result termed an intention superiority effect (Goschke & Kuhl, 1993). In the current study, we demonstrate an intention interference effect (IIE) in which colour-naming performance in a Stroop task was slower for words belonging to an intention that participants had to remember to carry out (Do the Task condition) versus an intention that did not have to be executed (Ignore the Task condition). In previous work (e.g., Cohen et al., 2005), having a prospective intention in mind was confounded with carrying a memory load. In Experiment 1, we added a digit-retention task to control for effects of cognitive load. In Experiment 2, we eliminated the memory confound in a new way, by comparing intention-related and control words within each trial. Results from both Experiments 1 and 2 revealed an intention interference effect suggesting that interference is very specific to the intention, not just to a memory load. PMID:21592940

  12. The locus of taboo context effects in picture naming.

    PubMed

    Hansen, Samuel J; McMahon, Katie L; Burt, Jennifer S; de Zubicaray, Greig I

    2016-07-20

    Speakers respond more slowly when naming pictures presented with taboo (i.e., offensive/embarrassing) than with neutral distractor words in the picture-word interference paradigm. Over four experiments, we attempted to localize the processing stage at which this effect occurs during word production and determine whether it reflects the socially offensive/embarrassing nature of the stimuli. Experiment 1 demonstrated taboo interference at early stimulus onset asynchronies of -150 ms and 0 ms although not at 150 ms. In Experiment 2, taboo distractors sharing initial phonemes with target picture names eliminated the interference effect. Using additive factors logic, Experiment 3 demonstrated that taboo interference and phonological facilitation effects do not interact, indicating that the two effects originate at different processing levels within the speech production system. In Experiment 4, interference was observed for masked taboo distractors, including those sharing initial phonemes with the target picture names, indicating that the effect cannot be attributed to a processing level involving responses in an output buffer. In two of the four experiments, the magnitude of the interference effect correlated significantly with arousal ratings of the taboo words. However, no significant correlations were found for either offensiveness or valence ratings. These findings are consistent with a locus for the taboo interference effect prior to the processing stage responsible for word form encoding. We propose a pre-lexical account in which taboo distractors capture attention at the expense of target picture processing due to their high arousal levels.

  13. A Rapid Convergent Low Complexity Interference Alignment Algorithm for Wireless Sensor Networks.

    PubMed

    Jiang, Lihui; Wu, Zhilu; Ren, Guanghui; Wang, Gangyi; Zhao, Nan

    2015-07-29

    Interference alignment (IA) is a novel technique that can effectively eliminate the interference and approach the sum capacity of wireless sensor networks (WSNs) when the signal-to-noise ratio (SNR) is high, by casting the desired signal and interference into different signal subspaces. The traditional alternating minimization interference leakage (AMIL) algorithm for IA shows good performance in high SNR regimes, however, the complexity of the AMIL algorithm increases dramatically as the number of users and antennas increases, posing limits to its applications in the practical systems. In this paper, a novel IA algorithm, called directional quartic optimal (DQO) algorithm, is proposed to minimize the interference leakage with rapid convergence and low complexity. The properties of the AMIL algorithm are investigated, and it is discovered that the difference between the two consecutive iteration results of the AMIL algorithm will approximately point to the convergence solution when the precoding and decoding matrices obtained from the intermediate iterations are sufficiently close to their convergence values. Based on this important property, the proposed DQO algorithm employs the line search procedure so that it can converge to the destination directly. In addition, the optimal step size can be determined analytically by optimizing a quartic function. Numerical results show that the proposed DQO algorithm can suppress the interference leakage more rapidly than the traditional AMIL algorithm, and can achieve the same level of sum rate as that of AMIL algorithm with far less iterations and execution time.

  14. 75 FR 76759 - Self-Regulatory Organizations; NYSE Amex LLC; Notice of Filing and Immediate Effectiveness of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-09

    ... To Eliminate Market and Stop Orders in Nasdaq-Listed Securities Traded on the Exchange December 2...--NYSE Amex Equities to eliminate Market and Stop Orders in Nasdaq-listed securities traded on the... eliminate Market and Stop Orders in Nasdaq-listed securities traded on the Exchange. Background Rules 500...

  15. Design, Fabrication and Characterization of a MEMS-Based Three-Dimensional Electric Field Sensor with Low Cross-Axis Coupling Interference

    PubMed Central

    Ling, Biyun; Peng, Chunrong; Ren, Ren; Chu, Zhaozhi; Zhang, Zhouwei; Lei, Hucheng; Xia, Shanhong

    2018-01-01

    One of the major concerns in the development of three-dimensional (3D) electric field sensors (EFSs) is their susceptibility to cross-axis coupling interference. The output signal for each sensing axis of a 3D EFS is often coupled by electric field components from the two other orthogonal sensing axes. In this paper, a one-dimensional (1D) electric field sensor chip (EFSC) with low cross-axis coupling interference is presented. It is designed to be symmetrical, forming a pair of in-plane symmetrically-located sensing structures. Using a difference circuit, the 1D EFSC is capable of sensing parallel electric fields along symmetrical structures and eliminating cross-axis coupling interference, which is contrast to previously reported 1D EFSCs designed for perpendicular electric field component measurement. Thus, a 3D EFS with low cross-axis coupling interference can be realized using three proposed 1D EFSCs. This 3D EFS has the advantages of low cross-axis coupling interference, small size, and high integration. The testing and calibration systems of the proposed 3D EFS were developed. Experimental results show that in the range of 0–120 kV/m, cross-axis sensitivities are within 5.48%, and the total measurement errors of this 3D EFS are within 6.16%. PMID:29543744

  16. TPH detection in groundwater: Identification and elimination of positive interferences

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zemo, D.A.; Synowiec, K.A.

    1996-01-01

    Groundwater assessment programs frequently require total petroleum hydrocarbon (TPH) analyses (Methods 8015M and 418.1). TPH analyses are often unreliable indicators of water quality because these methods are not constituent-specific and are vulnerable to significant sources of positive interferences. These positive interferences include: (a) non-dissolved petroleum constituents; (b) soluble, non-petroleum hydrocarbons (e.g., biodegradation products); and (c) turbidity, commonly introduced into water samples during sample collection. In this paper, we show that the portion of a TPH concentration not directly the result of water-soluble petroleum constituents can be attributed solely to these positive interferences. To demonstrate the impact of these interferences, wemore » conducted a field experiment at a site affected by degraded crude oil. Although TPH was consistently detected in groundwater samples, BTEX was not detected. PNAs were not detected, except for very low concentrations of fluorene (<5 ug/1). Filtering and silica gel cleanup steps were added to sampling and analyses to remove particulates and biogenic by-products. Results showed that filtering lowered the Method 8015M concentrations and reduced the Method 418.1 concentrations to non-detectable. Silica gel cleanup reduced the Method 8015M concentrations to non-detectable. We conclude from this study that the TPH results from groundwater samples are artifacts of positive interferences caused by both particulates and biogenic materials and do not represent dissolved-phase petroleum constituents.« less

  17. TPH detection in groundwater: Identification and elimination of positive interferences

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zemo, D.A.; Synowiec, K.A.

    1996-12-31

    Groundwater assessment programs frequently require total petroleum hydrocarbon (TPH) analyses (Methods 8015M and 418.1). TPH analyses are often unreliable indicators of water quality because these methods are not constituent-specific and are vulnerable to significant sources of positive interferences. These positive interferences include: (a) non-dissolved petroleum constituents; (b) soluble, non-petroleum hydrocarbons (e.g., biodegradation products); and (c) turbidity, commonly introduced into water samples during sample collection. In this paper, we show that the portion of a TPH concentration not directly the result of water-soluble petroleum constituents can be attributed solely to these positive interferences. To demonstrate the impact of these interferences, wemore » conducted a field experiment at a site affected by degraded crude oil. Although TPH was consistently detected in groundwater samples, BTEX was not detected. PNAs were not detected, except for very low concentrations of fluorene (<5 ug/1). Filtering and silica gel cleanup steps were added to sampling and analyses to remove particulates and biogenic by-products. Results showed that filtering lowered the Method 8015M concentrations and reduced the Method 418.1 concentrations to non-detectable. Silica gel cleanup reduced the Method 8015M concentrations to non-detectable. We conclude from this study that the TPH results from groundwater samples are artifacts of positive interferences caused by both particulates and biogenic materials and do not represent dissolved-phase petroleum constituents.« less

  18. Sources of interference in item and associative recognition memory.

    PubMed

    Osth, Adam F; Dennis, Simon

    2015-04-01

    A powerful theoretical framework for exploring recognition memory is the global matching framework, in which a cue's memory strength reflects the similarity of the retrieval cues being matched against the contents of memory simultaneously. Contributions at retrieval can be categorized as matches and mismatches to the item and context cues, including the self match (match on item and context), item noise (match on context, mismatch on item), context noise (match on item, mismatch on context), and background noise (mismatch on item and context). We present a model that directly parameterizes the matches and mismatches to the item and context cues, which enables estimation of the magnitude of each interference contribution (item noise, context noise, and background noise). The model was fit within a hierarchical Bayesian framework to 10 recognition memory datasets that use manipulations of strength, list length, list strength, word frequency, study-test delay, and stimulus class in item and associative recognition. Estimates of the model parameters revealed at most a small contribution of item noise that varies by stimulus class, with virtually no item noise for single words and scenes. Despite the unpopularity of background noise in recognition memory models, background noise estimates dominated at retrieval across nearly all stimulus classes with the exception of high frequency words, which exhibited equivalent levels of context noise and background noise. These parameter estimates suggest that the majority of interference in recognition memory stems from experiences acquired before the learning episode. (c) 2015 APA, all rights reserved).

  19. When Delays Improve Memory: Stabilizing Memory in Children May Require Time.

    PubMed

    Darby, Kevin P; Sloutsky, Vladimir M

    2015-12-01

    Memory is critical for learning, cognition, and cognitive development. Recent work has suggested that preschool-age children are vulnerable to catastrophic levels of memory interference, in which new learning dramatically attenuates memory for previously acquired knowledge. In the work reported here, we investigated the effects of consolidation on children's memory by introducing a 48-hr delay between learning and testing. In Experiment 1, the delay improved children's memory and eliminated interference. Results of Experiment 2 suggest that the benefit of this delay is limited to situations in which children are given enough information to form complex memory structures. These findings have important implications for understanding consolidation processes and memory development. © The Author(s) 2015.

  20. Reference-Frame-Independent and Measurement-Device-Independent Quantum Key Distribution Using One Single Source

    NASA Astrophysics Data System (ADS)

    Li, Qian; Zhu, Changhua; Ma, Shuquan; Wei, Kejin; Pei, Changxing

    2018-04-01

    Measurement-device-independent quantum key distribution (MDI-QKD) is immune to all detector side-channel attacks. However, practical implementations of MDI-QKD, which require two-photon interferences from separated independent single-photon sources and a nontrivial reference alignment procedure, are still challenging with current technologies. Here, we propose a scheme that significantly reduces the experimental complexity of two-photon interferences and eliminates reference frame alignment by the combination of plug-and-play and reference frame independent MDI-QKD. Simulation results show that the secure communication distance can be up to 219 km in the finite-data case and the scheme has good potential for practical MDI-QKD systems.

  1. Digital optical conversion module

    DOEpatents

    Kotter, D.K.; Rankin, R.A.

    1988-07-19

    A digital optical conversion module used to convert an analog signal to a computer compatible digital signal including a voltage-to-frequency converter, frequency offset response circuitry, and an electrical-to-optical converter. Also used in conjunction with the digital optical conversion module is an optical link and an interface at the computer for converting the optical signal back to an electrical signal. Suitable for use in hostile environments having high levels of electromagnetic interference, the conversion module retains high resolution of the analog signal while eliminating the potential for errors due to noise and interference. The module can be used to link analog output scientific equipment such as an electrometer used with a mass spectrometer to a computer. 2 figs.

  2. Digital optical conversion module

    DOEpatents

    Kotter, Dale K.; Rankin, Richard A.

    1991-02-26

    A digital optical conversion module used to convert an analog signal to a computer compatible digital signal including a voltage-to-frequency converter, frequency offset response circuitry, and an electrical-to-optical converter. Also used in conjunction with the digital optical conversion module is an optical link and an interface at the computer for converting the optical signal back to an electrical signal. Suitable for use in hostile environments having high levels of electromagnetic interference, the conversion module retains high resolution of the analog signal while eliminating the potential for errors due to noise and interference. The module can be used to link analog output scientific equipment such as an electrometer used with a mass spectrometer to a computer.

  3. Crew Quarters (CQ) and Electromagnetic Interference (EMI) Measurement Facility Combined Impedance Study

    NASA Technical Reports Server (NTRS)

    Scully, Robert C.

    2011-01-01

    This report documents an investigation into observed failures associated with conducted susceptibility testing of Crew Quarters (CQ) hardware in the Johnson Space Center (JSC) Electromagnetic Interference (EMI) Measurement Facility, and the work accomplished to identify the source of the observed behavior. Investigation led to the conclusion that the hardware power input impedance was interacting with the facility power impedance leading to instability at the observed frequencies of susceptibility. Testing performed in other facilities did not show this same behavior, pointing back to the EMI Measurement Facility power as the potential root cause. A LISN emulating the Station power bus impedance was inserted into the power circuit, and the susceptibility was eliminated from the measurements.

  4. Interference competition and invasion: spatial structure, novel weapons and resistance zones.

    PubMed

    Allstadt, Andrew; Caraco, Thomas; Molnár, F; Korniss, G

    2012-08-07

    Certain invasive plants may rely on interference mechanisms (e.g., allelopathy) to gain competitive superiority over native species. But expending resources on interference presumably exacts a cost in another life-history trait, so that the significance of interference competition for invasion ecology remains uncertain. We model ecological invasion when combined effects of preemptive and interference competition govern interactions at the neighborhood scale. We consider three cases. Under "novel weapons," only the initially rare invader exercises interference. For "resistance zones" only the resident species interferes, and finally we take both species as interference competitors. Interference increases the other species' mortality, opening space for colonization. However, a species exercising greater interference has reduced propagation, which can hinder its colonization of open sites. Interference never enhances a rare invader's growth in the homogeneously mixing approximation to our model. But interference can significantly increase an invader's competitiveness, and its growth when rare, if interactions are structured spatially. That is, interference can increase an invader's success when colonization of open sites depends on local, rather than global, species densities. In contrast, interference enhances the common, resident species' resistance to invasion independently of spatial structure, unless the propagation-cost is too great. The particular combination of propagation and interference producing the strongest biotic resistance in a resident species depends on the shape of the tradeoff between the two traits. Increases in background mortality (i.e., mortality not due to interference) always reduce the effectiveness of interference competition. Copyright © 2012 Elsevier Ltd. All rights reserved.

  5. Recovering fNIRS brain signals: physiological interference suppression with independent component analysis

    NASA Astrophysics Data System (ADS)

    Zhang, Y.; Shi, M.; Sun, J.; Yang, C.; Zhang, Yajuan; Scopesi, F.; Makobore, P.; Chin, C.; Serra, G.; Wickramasinghe, Y. A. B. D.; Rolfe, P.

    2015-02-01

    Brain activity can be monitored non-invasively by functional near-infrared spectroscopy (fNIRS), which has several advantages in comparison with other methods, such as flexibility, portability, low cost and fewer physical restrictions. However, in practice fNIRS measurements are often contaminated by physiological interference arising from cardiac contraction, breathing and blood pressure fluctuations, thereby severely limiting the utility of the method. Hence, further improvement is necessary to reduce or eliminate such interference in order that the evoked brain activity information can be extracted reliably from fNIRS data. In the present paper, the multi-distance fNIRS probe configuration has been adopted. The short-distance fNIRS measurement is treated as the virtual channel and the long-distance fNIRS measurement is treated as the measurement channel. Independent component analysis (ICA) is employed for the fNIRS recordings to separate the brain signals and the interference. Least-absolute deviation (LAD) estimator is employed to recover the brain activity signals. We also utilized Monte Carlo simulations based on a five-layer model of the adult human head to evaluate our methodology. The results demonstrate that the ICA algorithm has the potential to separate physiological interference in fNIRS data and the LAD estimator could be a useful criterion to recover the brain activity signals.

  6. Adaptive wall research with two- and three-dimensional models in low speed and transonic tunnels

    NASA Technical Reports Server (NTRS)

    Lewis, M. C.; Neal, G.; Goodyer, M. J.

    1988-01-01

    This paper summarises recent research at the University of Southampton into adaptive wall technology and outlines the direction of current efforts. The work is aimed at developing techniques for use in test sections where the top and bottom walls may be adjusted in single curvature. Wall streamlining eliminates, as far as experimentally possible, the top and bottom wall interference in low speed and transonic aerofoil testing. A streamlining technique has been developed for low speeds which allows the testing of swept wing panels in low interference environments. At higher speeds, a comparison of several two-dimensional transonic streamlining algorithms has been made and a technique for streamlining with a choked test section has also been developed. Three-dimensional work has mainly concentrated on tests of sidewall mounted half-wings and the development of the software packages required to assess interference and to adjust the flexible walls. It has been demonstrated that two-dimensional wall adaptation can significantly modify the level of wall interference around relatively large three-dimensional models. The residual interferences are small and are probably amenable to standard post-test correction methods. Tests on a calibrated wing-body model are planned in the near future to further validate the proposed streamlining technique.

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Deng, Dr. Yanhua; McCandless, Andrew Bascom

    The main objective of this project is to improve the performance and reliability of sensor networks in the smart grid through an active interference cancellation technique that can effectively eliminate broadband electromagnetic interference (EMI) and radio frequency interference (RFI). This noise cancellation provides real-time monitoring the RF environment and automatically optimization of the signal fidelity. To determine the feasibility of the proposed technique and quantify the level of improvement in key system parameters, such as data rate, signal bandwidth, and cost saving, the tasks carried out during Phase I were 1) defining the problem statement, 2) developing a design thatmore » will solve the sensors’ reliably problem, 3) carrying out initial testing with a prototype, and 4) developing an integrated photonic chip version that could be built in a follow-on Phase II effort. The technology demonstration was successfully proven the feasibility of a mission assured photonic sensor system (MAPSS) that will address a major interference problem in smart grid deployments. The significant results demonstrated from bench-top testing show that the technology is capable of maintaining the error free communication link in the presence of various type of interference. The technology’s wideband performance in GHz is also verified and would be suitable for sensors deploying throughout the smart grid system.« less

  8. Depth Profiles of Mg, Si, and Zn Implants in GaN by Trace Element Accelerator Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Ravi Prasad, G. V.; Pelicon, P.; Mitchell, L. J.; McDaniel, F. D.

    2003-08-01

    GaN is one of the most promising electronic materials for applications requiring high-power, high frequencies, or high-temperatures as well as opto-electronics in the blue to ultraviolet spectral region. We have recently measured depth profiles of Mg, Si, and Zn implants in GaN substrates by the TEAMS particle counting method for both matrix and trace elements, using a gas ionization chamber. Trace Element Accelerator Mass Spectrometry (TEAMS) is a combination of Secondary Ion Mass Spectrometry (SIMS) and Accelerator Mass Spectrometry (AMS) to measure trace elements at ppb levels. Negative ions from a SIMS like source are injected into a tandem accelerator. Molecular interferences inherent with the SIMS method are eliminated in the TEAMS method. Negative ion currents are extremely low with GaN as neither gallium nor nitrogen readily forms negative ions making the depth profile measurements more difficult. The energies of the measured ions are in the range of 4-8 MeV. A careful selection of mass/charge ratios of the detected ions combined with energy-loss behavior of the ions in the ionization chamber eliminated molecular interferences.

  9. Experimental analysis in recording transmission and reflection holograms at the same time and location.

    PubMed

    Toishi, Mitsuru; Tanaka, Tomiji; Watanabe, Kenjiro

    2006-09-01

    Holographic recording media with a reflection layer are useful because they make it possible to maintain backward compatibility with CDs and DVDs, and a conventional servo system is easily attachable. The incident beam is fed back to the recording layer by the reflection layer, so there are four beam pairs to record the transmission and reflection holograms. We analyze the basic property of the transmission and reflection holograms and evaluate the problem when the transmission and reflection holograms are recorded at the same time. It is shown that the shrinkage in the photopolymer medium has a different effect on each hologram, so the readout image from the two holograms is misaligned. Those diffraction beams make the interference pattern, and the signal-to-noise ratio (SNR) of the output image decreased. Taking into account the difference in wavelength selectivity between the transmission and the reflection holograms, we propose a way to select one hologram to get the diffraction beam and eliminate the interference pattern using the tuning readout wavelength. By using this method, we can eliminate the diffraction beam from the reflection hologram and keep a high SNR.

  10. 27nt-RNAs guide histone variant deposition via 'RNA-induced DNA replication interference' and thus transmit parental genome partitioning in Stylonychia.

    PubMed

    Postberg, Jan; Jönsson, Franziska; Weil, Patrick Philipp; Bulic, Aneta; Juranek, Stefan Andreas; Lipps, Hans-Joachim

    2018-06-12

    During sexual reproduction in the unicellular ciliate Stylonychia somatic macronuclei differentiate from germline micronuclei. Thereby, programmed sequence reduction takes place, leading to the elimination of > 95% of germline sequences, which priorly adopt heterochromatin structure via H3K27me3. Simultaneously, 27nt-ncRNAs become synthesized from parental transcripts and are bound by the Argonaute protein PIWI1. These 27nt-ncRNAs cover sequences destined to the developing macronucleus and are thought to protect them from degradation. We provide evidence and propose that RNA/DNA base-pairing guides PIWI1/27nt-RNA complexes to complementary macronucleus-destined DNA target sequences, hence transiently causing locally stalled replication during polytene chromosome formation. This spatiotemporal delay enables the selective deposition of temporarily available histone H3.4K27me3 nucleosomes at all other sequences being continuously replicated, thus dictating their prospective heterochromatin structure before becoming developmentally eliminated. Concomitantly, 27nt-RNA-covered sites remain protected. We introduce the concept of 'RNA-induced DNA replication interference' and explain how the parental functional genome partition could become transmitted to the progeny.

  11. Addressing EO-1 Spacecraft Pulsed Plasma Thruster EMI Concerns

    NASA Technical Reports Server (NTRS)

    Zakrzwski, C. M.; Davis, Mitch; Sarmiento, Charles; Bauer, Frank H. (Technical Monitor)

    2001-01-01

    The Pulsed Plasma Thruster (PPT) Experiment on the Earth Observing One (EO-1) spacecraft has been designed to demonstrate the capability of a new generation PPT to perform spacecraft attitude control. Results from PPT unit level radiated electromagnetic interference (EMI) tests led to concerns about potential interference problems with other spacecraft subsystems. Initial plans to address these concerns included firing the PPT at the spacecraft level both in atmosphere, with special ground support equipment. and in vacuum. During the spacecraft level tests, additional concerns where raised about potential harm to the Advanced Land Imager (ALI). The inadequacy of standard radiated emission test protocol to address pulsed electromagnetic discharges and the lack of resources required to perform compatibility tests between the PPT and an ALI test unit led to changes in the spacecraft level validation plan. An EMI shield box for the PPT was constructed and validated for spacecraft level ambient testing. Spacecraft level vacuum tests of the PPT were deleted. Implementation of the shield box allowed for successful spacecraft level testing of the PPT while eliminating any risk to the ALI. The ALI demonstration will precede the PPT demonstration to eliminate any possible risk of damage of ALI from PPT operation.

  12. D-METHIONINE REDUCES TOBRAMYCIN-INDUCED OTOTOXICITY WITHOUT ANTIMICROBIAL INTERFERENCE IN ANIMAL MODELS

    PubMed Central

    Fox, Daniel J.; Cooper, Morris D.; Speil, Cristian A.; Roberts, Melissa H.; Yanik, Susan C.; Meech, Robert P.; Hargrove, Tim L.; Verhulst, Steven J.; Rybak, Leonard P.; Campbell, Kathleen C. M.

    2015-01-01

    Background Tobramycin is a critical cystic fibrosis treatment however it causes ototoxicity. This study tested D-methionine protection from tobramycin-induced ototoxicity and potential antimicrobial interference. Methods Auditory brainstem responses (ABR) and outer hair cell (OHC) quantifications measured protection in guinea pigs treated with tobramycin and a range of D-methionine doses. In vitro antimicrobial interference studies tested inhibition and post antibiotic effect assays. In vivo antimicrobial interference studies tested normal and neutropenic E. coli murine survival and intraperitoneal lavage bacterial counts. Results D-methionine conferred significant ABR threshold shift reductions. OHC protection was less robust but significant at 20 kHz in the 420 mg/kg/day group. In vitro studies did not detect D-methionine-induced antimicrobial interference. In vivo studies did not detect D-methionine-induced interference in normal or neutropenic mice. Conclusions D-methionine protects from tobramycin-induced ototoxicity without antimicrobial interference. The study results suggest D-met as a potential otoprotectant from clinical tobramycin use in cystic fibrosis patients. PMID:26166286

  13. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Roberson, G P; Logan, C M

    We have estimated interference from external background radiation for a computed tomography (CT) scanner. Our intention is to estimate the interference that would be expected for the high-resolution SkyScan 1072 desk-top x-ray microtomography system. The SkyScan system uses a Microfocus x-ray source capable of a 10-{micro}m focal spot at a maximum current of 0.1 mA and a maximum energy of 130 kVp. All predictions made in this report assume using the x-ray source at the smallest spot size, maximum energy, and operating at the maximum current. Some of the systems basic geometry that is used for these estimates are: (1)more » Source-to-detector distance: 250 mm, (2) Minimum object-to-detector distance: 40 mm, and (3) Maximum object-to-detector distance: 230 mm. This is a first-order, rough estimate of the quantity of interference expected at the system detector caused by background radiation. The amount of interference is expressed by using the ratio of exposure expected at the detector of the CT system. The exposure values for the SkyScan system are determined by scaling the measured values of an x-ray source and the background radiation adjusting for the difference in source-to-detector distance and current. The x-ray source that was used for these measurements was not the SkyScan Microfocus x-ray tube. Measurements were made using an x-ray source that was operated at the same applied voltage but higher current for better statistics.« less

  14. [The validation of the effect of correcting spectral background changes based on floating reference method by simulation].

    PubMed

    Wang, Zhu-lou; Zhang, Wan-jie; Li, Chen-xi; Chen, Wen-liang; Xu, Ke-xin

    2015-02-01

    There are some challenges in near-infrared non-invasive blood glucose measurement, such as the low signal to noise ratio of instrument, the unstable measurement conditions, the unpredictable and irregular changes of the measured object, and etc. Therefore, it is difficult to extract the information of blood glucose concentrations from the complicated signals accurately. Reference measurement method is usually considered to be used to eliminate the effect of background changes. But there is no reference substance which changes synchronously with the anylate. After many years of research, our research group has proposed the floating reference method, which is succeeded in eliminating the spectral effects induced by the instrument drifts and the measured object's background variations. But our studies indicate that the reference-point will changes following the changing of measurement location and wavelength. Therefore, the effects of floating reference method should be verified comprehensively. In this paper, keeping things simple, the Monte Carlo simulation employing Intralipid solution with the concentrations of 5% and 10% is performed to verify the effect of floating reference method used into eliminating the consequences of the light source drift. And the light source drift is introduced through varying the incident photon number. The effectiveness of the floating reference method with corresponding reference-points at different wavelengths in eliminating the variations of the light source drift is estimated. The comparison of the prediction abilities of the calibration models with and without using this method shows that the RMSEPs of the method are decreased by about 98.57% (5%Intralipid)and 99.36% (10% Intralipid)for different Intralipid. The results indicate that the floating reference method has obvious effect in eliminating the background changes.

  15. Adaptive detection of noise signal according to Neumann-Pearson criterion

    NASA Astrophysics Data System (ADS)

    Padiryakov, Y. A.

    1985-03-01

    Optimum detection according to the Neumann-Pearson criterion is considered in the case of a random Gaussian noise signal, stationary during measurement, and a stationary random Gaussian background interference. Detection is based on two samples, their statistics characterized by estimates of their spectral densities, it being a priori known that sample A from the signal channel is either the sum of signal and interference or interference alone and sample B from the reference interference channel is an interference with the same spectral density as that of the interference in sample A for both hypotheses. The probability of correct detection is maximized on the average, first in the 2N-dimensional space of signal spectral density and interference spectral density readings, by fixing the probability of false alarm at each point so as to stabilize it at a constant level against variation of the interference spectral density. Deterministic decision rules are established. The algorithm is then reduced to equivalent detection in the N-dimensional space of the ratio of sample A readings to sample B readings.

  16. Method and apparatus for removing unwanted reflections from an interferometer

    NASA Technical Reports Server (NTRS)

    Steimle, Lawrence J. (Inventor); Thiessen, David L. (Inventor)

    1994-01-01

    A device for eliminating unwanted reflections from refractive optical elements in an optical system is provided. The device operates to prevent desired multiple fringe patterns from being obscured by reflections from refractive elements positioned in proximity to a focal plane of the system. The problem occurs when an optical beam is projected into, and reflected back out of, the optical system. Surfaces of the refractive elements reflect portions of the beam which interfere with portions of the beam which are transmitted through the refractive elements. Interference between the reflected and transmitted portions of the beam produce multiple fringe sets which tend to obscure desired interference fringes. With the refractive optical element in close proximity to the focal plane of the system, the undesired reflected light reflects at an angle 180 degrees opposite from the desired transmitted beam. The device exploits the 180-degree offset, or rotational shear, of the undesired reflected light by providing an optical stop for blocking one-half of the cross-section of the test beam. By blocking one-half of the test beam, the undesired offset beam is blocked, while the returning transmitted beam passes into the optical system unaffected. An image is thereby produced from only the desired transmitted beam. In one configuration, the blocking device includes a semicircular aperture which is caused to rotate about the axis of the test beam. By rotating, all portions of the test beam are cyclically projected into the optical system to thereby produce a complete test image. The rotating optical stop is preferably caused to rotate rapidly to eliminate flicker in the resulting image.

  17. Immunodominance: a new hypothesis to explain parasite escape and host/parasite equilibrium leading to the chronic phase of Chagas' disease?

    PubMed

    Rodrigues, M M; Alencar, B C G de; Claser, C; Tzelepis, F

    2009-03-01

    Intense immune responses are observed during human or experimental infection with the digenetic protozoan parasite Trypanosoma cruzi. The reasons why such immune responses are unable to completely eliminate the parasites are unknown. The survival of the parasite leads to a parasite-host equilibrium found during the chronic phase of chagasic infection in most individuals. Parasite persistence is recognized as the most likely cause of the chagasic chronic pathologies. Therefore, a key question in Chagas' disease is to understand how this equilibrium is established and maintained for a long period. Understanding the basis for this equilibrium may lead to new approaches to interventions that could help millions of individuals at risk for infection or who are already infected with T. cruzi. Here, we propose that the phenomenon of immunodominance may be significant in terms of regulating the host-parasite equilibrium observed in Chagas' disease. T. cruzi infection restricts the repertoire of specific T cells generating, in some cases, an intense immunodominant phenotype and in others causing a dramatic interference in the response to distinct epitopes. This immune response is sufficiently strong to maintain the host alive during the acute phase carrying them to the chronic phase where transmission usually occurs. At the same time, immunodominance interferes with the development of a higher and broader immune response that could be able to completely eliminate the parasite. Based on this, we discuss how we can interfere with or take advantage of immunodominance in order to provide an immunotherapeutic alternative for chagasic individuals.

  18. Application of enhanced gas chromatography/triple quadrupole mass spectrometry for monitoring petroleum weathering and forensic source fingerprinting in samples impacted by the Deepwater Horizon oil spill.

    PubMed

    Adhikari, Puspa L; Wong, Roberto L; Overton, Edward B

    2017-10-01

    Accurate characterization of petroleum hydrocarbons in complex and weathered oil residues is analytically challenging. This is primarily due to chemical compositional complexity of both the oil residues and environmental matrices, and the lack of instrumental selectivity due to co-elution of interferences with the target analytes. To overcome these analytical selectivity issues, we used an enhanced resolution gas chromatography coupled with triple quadrupole mass spectrometry in Multiple Reaction Monitoring (MRM) mode (GC/MS/MS-MRM) to eliminate interferences within the ion chromatograms of target analytes found in environmental samples. This new GC/MS/MS-MRM method was developed and used for forensic fingerprinting of deep-water and marsh sediment samples containing oily residues from the Deepwater Horizon oil spill. The results showed that the GC/MS/MS-MRM method increases selectivity, eliminates interferences, and provides more accurate quantitation and characterization of trace levels of alkyl-PAHs and biomarker compounds, from weathered oil residues in complex sample matrices. The higher selectivity of the new method, even at low detection limits, provides greater insights on isomer and homolog compositional patterns and the extent of oil weathering under various environmental conditions. The method also provides flat chromatographic baselines for accurate and unambiguous calculation of petroleum forensic biomarker compound ratios. Thus, this GC/MS/MS-MRM method can be a reliable analytical strategy for more accurate and selective trace level analyses in petroleum forensic studies, and for tacking continuous weathering of oil residues. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Validity, cut-points, and minimally important differences for two hot flash-related daily interference scales.

    PubMed

    Carpenter, Janet S; Bakoyannis, Giorgos; Otte, Julie L; Chen, Chen X; Rand, Kevin L; Woods, Nancy; Newton, Katherine; Joffe, Hadine; Manson, JoAnn E; Freeman, Ellen W; Guthrie, Katherine A

    2017-08-01

    To conduct psychometric analyses to condense the Hot Flash-Related Daily Interference Scale (HFRDIS) into a shorter form termed the Hot Flash Interference (HFI) scale; evaluate cut-points for both scales; and establish minimally important differences (MIDs) for both scales. We analyzed baseline and postrandomization patient-reported data pooled across three randomized trials aimed at reducing vasomotor symptoms (VMS) in 899 midlife women. Trials were conducted across five MsFLASH clinical sites between July 2009 and October 2012. We eliminated HFRDIS items based on experts' content validity ratings and confirmatory factor analysis, and evaluated cut-points and established MIDs by mapping HFRDIS and HFI to other measures. The three-item HFI (interference with sleep, mood, and concentration) demonstrated strong internal consistency (alphas of 0.830 and 0.856), showed good fit to the unidimensional "hot flash interference factor," and strong convergent validity with HFRDIS scores, diary VMS, and menopausal quality of life. For both scales, cut-points of mild (0-3.9), moderate (4-6.9), and severe (7-10) interference were associated with increasing diary VMS ratings, sleep, and anxiety. The average MID was 1.66 for the HFRDIS and 2.34 for the HFI. The HFI is a brief assessment of VMS interference and will be useful in busy clinics to standardize VMS assessment or in research studies where response burden may be an issue. The scale cut-points and MIDs should prove useful in targeting those most in need of treatment, monitoring treatment response, and interpreting existing and future research findings.

  20. Shared and Disorder-Specific Prefrontal Abnormalities in Boys with Pure Attention-Deficit/Hyperactivity Disorder Compared to Boys with Pure CD during Interference Inhibition and Attention Allocation

    ERIC Educational Resources Information Center

    Rubia, Katya; Halari, Rozmin; Smith, Anna B.; Mohammad, Majeed; Scott, Stephen; Brammer, Michael J.

    2009-01-01

    Background: Inhibitory and attention deficits have been suggested to be shared problems of disruptive behaviour disorders. Patients with attention deficit hyperactivity disorder (ADHD) and patients with conduct disorder (CD) show deficits in tasks of attention allocation and interference inhibition. However, functional magnetic resonance imaging…

  1. Increased Sensitivity to Proactive and Retroactive Interference in Amnestic Mild Cognitive Impairment: New Insights

    ERIC Educational Resources Information Center

    Hanseeuw, Bernard J.; Seron, Xavier; Ivanoiu, Adrian

    2012-01-01

    Background: Increased sensitivity to proactive (PI) and retroactive (RI) interference has been observed in amnestic mild cognitive impairment (aMCI). PI and RI are often explained as being the result of a response competition mechanism. However, patients with aMCI are supposed to suffer mostly from encoding deficits. We hypothesized that in aMCI…

  2. The location and recognition of anti-counterfeiting code image with complex background

    NASA Astrophysics Data System (ADS)

    Ni, Jing; Liu, Quan; Lou, Ping; Han, Ping

    2017-07-01

    The order of cigarette market is a key issue in the tobacco business system. The anti-counterfeiting code, as a kind of effective anti-counterfeiting technology, can identify counterfeit goods, and effectively maintain the normal order of market and consumers' rights and interests. There are complex backgrounds, light interference and other problems in the anti-counterfeiting code images obtained by the tobacco recognizer. To solve these problems, the paper proposes a locating method based on Susan operator, combined with sliding window and line scanning,. In order to reduce the interference of background and noise, we extract the red component of the image and convert the color image into gray image. For the confusing characters, recognition results correction based on the template matching method has been adopted to improve the recognition rate. In this method, the anti-counterfeiting code can be located and recognized correctly in the image with complex background. The experiment results show the effectiveness and feasibility of the approach.

  3. Interference of medical contrast media on laboratory testing.

    PubMed

    Lippi, Giuseppe; Daves, Massimo; Mattiuzzi, Camilla

    2014-01-01

    The use of contrast media such as organic iodine molecules and gadolinium contrast agents is commonplace in diagnostic imaging. Although there is widespread perception that side effects and drug interactions may be the leading problems caused by these compounds, various degrees of interference with some laboratory tests have been clearly demonstrated. Overall, the described interference for iodinate contrast media include inappropriate gel barrier formation in blood tubes, the appearance of abnormal peaks in capillary zone electrophoresis of serum proteins, and a positive bias in assessment of cardiac troponin I with one immunoassay. The interference for gadolinium contrast agents include negative bias in calcium assessment with ortho-cresolphthalein colorimetric assays and occasional positive bias using some Arsenazo reagents, negative bias in measurement of angiotensin converting enzyme (ACE) and zinc (colorimetric assay), as well as positive bias in creatinine (Jaffe reaction), total iron binding capacity (TIBC, ferrozine method), magnesium (calmagite reagent) and selenium (mass spectrometry) measurement. Interference has also been reported in assessment of serum indices, pulse oximetry and methaemoglobin in samples of patients receiving Patent Blue V. Under several circumstances the interference was absent from manufacturer-supplied information and limited to certain type of reagents and/or analytes, so that local verification may be advisable to establish whether or not the test in use may be biased. Since the elimination half-life of these compounds is typically lower than 2 h, blood collection after this period may be a safer alternative in patients who have received contrast media for diagnostic purposes.

  4. Interference of medical contrast media on laboratory testing

    PubMed Central

    Lippi, Giuseppe; Daves, Massimo; Mattiuzzi, Camilla

    2014-01-01

    The use of contrast media such as organic iodine molecules and gadolinium contrast agents is commonplace in diagnostic imaging. Although there is widespread perception that side effects and drug interactions may be the leading problems caused by these compounds, various degrees of interference with some laboratory tests have been clearly demonstrated. Overall, the described interference for iodinate contrast media include inappropriate gel barrier formation in blood tubes, the appearance of abnormal peaks in capillary zone electrophoresis of serum proteins, and a positive bias in assessment of cardiac troponin I with one immunoassay. The interference for gadolinium contrast agents include negative bias in calcium assessment with ortho-cresolphthalein colorimetric assays and occasional positive bias using some Arsenazo reagents, negative bias in measurement of angiotensin converting enzyme (ACE) and zinc (colorimetric assay), as well as positive bias in creatinine (Jaffe reaction), total iron binding capacity (TIBC, ferrozine method), magnesium (calmagite reagent) and selenium (mass spectrometry) measurement. Interference has also been reported in assessment of serum indices, pulse oximetry and methaemoglobin in samples of patients receiving Patent Blue V. Under several circumstances the interference was absent from manufacturer-supplied information and limited to certain type of reagents and/or analytes, so that local verification may be advisable to establish whether or not the test in use may be biased. Since the elimination half-life of these compounds is typically lower than 2 h, blood collection after this period may be a safer alternative in patients who have received contrast media for diagnostic purposes. PMID:24627717

  5. Active elimination of radio frequency interference for improved signal-to-noise ratio for in-situ NMR experiments in strong magnetic field gradients

    NASA Astrophysics Data System (ADS)

    Ibrahim, M.; Pardi, C. I.; Brown, T. W. C.; McDonald, P. J.

    2018-02-01

    Improvement in the signal-to-noise ratio of Nuclear Magnetic Resonance (NMR) systems may be achieved either by increasing the signal amplitude or by decreasing the noise. The noise has multiple origins - not all of which are strictly "noise": incoherent thermal noise originating in the probe and pre-amplifiers, probe ring down or acoustic noise and coherent externally broadcast radio frequency transmissions. The last cannot always be shielded in open access experiments. In this paper, we show that pulsed, low radio-frequency data communications are a significant source of broadcast interference. We explore two signal processing methods of de-noising short T2∗ NMR experiments corrupted by these communications: Linear Predictive Coding (LPC) and the Discrete Wavelet Transform (DWT). Results are shown for numerical simulations and experiments conducted under controlled conditions with pseudo radio frequency interference. We show that both the LPC and DWT methods have merit.

  6. Endocrine Disrupting Chemicals and Disease Susceptibility

    PubMed Central

    Schug, Thaddeus T.; Janesick, Amanda; Blumberg, Bruce; Heindel, Jerrold J.

    2011-01-01

    Environmental chemicals have significant impacts on biological systems. Chemical exposures during early stages of development can disrupt normal patterns of development and thus dramatically alter disease susceptibility later in life. Endocrine disrupting chemicals (EDCs) interfere with the body's endocrine system and produce adverse developmental, reproductive, neurological, cardiovascular, metabolic and immune effects in humans. A wide range of substances, both natural and man-made, are thought to cause endocrine disruption, including pharmaceuticals, dioxin and dioxin-like compounds, polychlorinated biphenyls, DDT and other pesticides, and components of plastics such as bisphenol A (BPA) and phthalates. EDCs are found in many everyday products– including plastic bottles, metal food cans, detergents, flame retardants, food additives, toys, cosmetics, and pesticides. EDCs interfere with the synthesis, secretion, transport, activity, or elimination of natural hormones. This interference can block or mimic hormone action, causing a wide range of effects. This review focuses on the mechanisms and modes of action by which EDCs alter hormone signaling. It also includes brief overviews of select disease endpoints associated with endocrine disruption. PMID:21899826

  7. Endocrine disrupting chemicals and disease susceptibility.

    PubMed

    Schug, Thaddeus T; Janesick, Amanda; Blumberg, Bruce; Heindel, Jerrold J

    2011-11-01

    Environmental chemicals have significant impacts on biological systems. Chemical exposures during early stages of development can disrupt normal patterns of development and thus dramatically alter disease susceptibility later in life. Endocrine disrupting chemicals (EDCs) interfere with the body's endocrine system and produce adverse developmental, reproductive, neurological, cardiovascular, metabolic and immune effects in humans. A wide range of substances, both natural and man-made, are thought to cause endocrine disruption, including pharmaceuticals, dioxin and dioxin-like compounds, polychlorinated biphenyls, DDT and other pesticides, and components of plastics such as bisphenol A (BPA) and phthalates. EDCs are found in many everyday products--including plastic bottles, metal food cans, detergents, flame retardants, food additives, toys, cosmetics, and pesticides. EDCs interfere with the synthesis, secretion, transport, activity, or elimination of natural hormones. This interference can block or mimic hormone action, causing a wide range of effects. This review focuses on the mechanisms and modes of action by which EDCs alter hormone signaling. It also includes brief overviews of select disease endpoints associated with endocrine disruption. Published by Elsevier Ltd.

  8. Spectrum-averaged Harmonic Path (SHAPA) algorithm for non-contact vital sign monitoring with ultra-wideband (UWB) radar.

    PubMed

    Van Nguyen; Javaid, Abdul Q; Weitnauer, Mary Ann

    2014-01-01

    We introduce the Spectrum-averaged Harmonic Path (SHAPA) algorithm for estimation of heart rate (HR) and respiration rate (RR) with Impulse Radio Ultrawideband (IR-UWB) radar. Periodic movement of human torso caused by respiration and heart beat induces fundamental frequencies and their harmonics at the respiration and heart rates. IR-UWB enables capture of these spectral components and frequency domain processing enables a low cost implementation. Most existing methods of identifying the fundamental component either in frequency or time domain to estimate the HR and/or RR lead to significant error if the fundamental is distorted or cancelled by interference. The SHAPA algorithm (1) takes advantage of the HR harmonics, where there is less interference, and (2) exploits the information in previous spectra to achieve more reliable and robust estimation of the fundamental frequency in the spectrum under consideration. Example experimental results for HR estimation demonstrate how our algorithm eliminates errors caused by interference and produces 16% to 60% more valid estimates.

  9. Experimental investigation of wall shock cancellation and reduction of wall interference in transonic testing

    NASA Technical Reports Server (NTRS)

    Ferri, A.; Roffe, G.

    1975-01-01

    A series of experiments were performed to evaluate the effectiveness of a three-dimensional land and groove wall geometry and a variable permeability distribution to reduce the interference produced by the porous walls of a supercritical transonic test section. The three-dimensional wall geometry was found to diffuse the pressure perturbations caused by small local mismatches in wall porosity permitting the use of a relatively coarse wall porosity control to reduce or eliminate wall interference effects. The wall porosity distribution required was found to be a sensitive function of Mach number requiring that the Mach number repeatability characteristics of the test apparatus be quite good. The effectiveness of a variable porosity wall is greatest in the upstream region of the test section where the pressure differences across the wall are largest. An effective variable porosity wall in the down stream region of the test section requires the use of a slightly convergent test section geometry.

  10. The intention interference effect.

    PubMed

    Cohen, Anna-Lisa; Kantner, Justin; Dixon, Roger A; Lindsay, D Stephen

    2011-01-01

    Intentions have been shown to be more accessible (e.g., more quickly and accurately recalled) compared to other sorts of to-be-remembered information; a result termed an intention superiority effect (Goschke & Kuhl, 1993). In the current study, we demonstrate an intention interference effect (IIE) in which color-naming performance in a Stroop task was slower for words belonging to an intention that participants had to remember to carry out (Do-the-Task condition) versus an intention that did not have to be executed (Ignore-the-Task condition). In previous work (e.g., Cohen et al., 2005), having a prospective intention in mind was confounded with carrying a memory load. In Experiment 1, we added a digit-retention task to control for effects of cognitive load. In Experiment 2, we eliminated the memory confound in a new way, by comparing intention-related and control words within each trial. Results from both Experiments 1 and 2 revealed an IIE suggesting that interference is very specific to the intention, not just to a memory load.

  11. Noise correction on LANDSAT images using a spline-like algorithm

    NASA Technical Reports Server (NTRS)

    Vijaykumar, N. L. (Principal Investigator); Dias, L. A. V.

    1985-01-01

    Many applications using LANDSAT images face a dilemma: the user needs a certain scene (for example, a flooded region), but that particular image may present interference or noise in form of horizontal stripes. During automatic analysis, this interference or noise may cause false readings of the region of interest. In order to minimize this interference or noise, many solutions are used, for instane, that of using the average (simple or weighted) values of the neighboring vertical points. In the case of high interference (more than one adjacent line lost) the method of averages may not suit the desired purpose. The solution proposed is to use a spline-like algorithm (weighted splines). This type of interpolation is simple to be computer implemented, fast, uses only four points in each interval, and eliminates the necessity of solving a linear equation system. In the normal mode of operation, the first and second derivatives of the solution function are continuous and determined by data points, as in cubic splines. It is possible, however, to impose the values of the first derivatives, in order to account for shapr boundaries, without increasing the computational effort. Some examples using the proposed method are also shown.

  12. Viagra warning re "poppers" and notice re protease inhibitors.

    PubMed

    James, J S

    1998-05-01

    Pfizer, Inc., manufacturer of Viagra (sildenafil), is warning patients that Viagra is contraindicated with nitrate inhalers (poppers). Nitrates in any form or nitric oxide donors can potentially cause hypotension. Pfizer also recommends that patients using protease inhibitors, particularly ritonavir, use a lower dose of Viagra (25 mg) because they interfere with the elimination of Viagra. This interaction does not pose a significant risk to the patient.

  13. The determination of copper in biological materials by flame spectrophotometry

    PubMed Central

    Newman, G. E.; Ryan, M.

    1962-01-01

    A method for the determination of the copper content of biological materials by flame spectrophotometry is described. The effects of interference by ions such as sodium and phosphate were eliminated by isolating copper as the dithizonate in CCl4. Results obtained for the urinary excretion of copper by a patient with Wilson's disease before and after treatment with penicillamine are reported. PMID:14479334

  14. Weakly Deleterious Mutations and Low Rates of Recombination Limit the Impact of Natural Selection on Bacterial Genomes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Price, Morgan N.; Arkin, Adam P.

    Free-living bacteria are usually thought to have large effective population sizes, and so tiny selective differences can drive their evolution. However, because recombination is infrequent, “background selection” against slightly deleterious alleles should reduce the effective population size (N e) by orders of magnitude. For example, for a well-mixed population with 10 12 individuals and a typical level of homologous recombination (r/m= 3, i.e., nucleotide changes due to recombination [r] occur at 3 times the mutation rate [m]), we predict that N e is<10 7. An argument for high N e values for bacteria has been the high genetic diversity withinmore » many bacterial “species,” but this diversity may be due to population structure: diversity across subpopulations can be far higher than diversity within a subpopulation, which makes it difficult to estimate N e correctly. Given an estimate ofN e, standard population genetics models imply that selection should be sufficient to drive evolution if N e ×s is >1, where s is the selection coefficient. We found that this remains approximately correct if background selection is occurring or when population structure is present. Overall, we predict that even for free-living bacteria with enormous populations, natural selection is only a significant force ifs is above 10 -7 or so. Because bacteria form huge populations with trillions of individuals, the simplest theoretical prediction is that the better allele at a site would predominate even if its advantage was just 10 -9 per generation. In other words, virtually every nucleotide would be at the local optimum in most individuals. A more sophisticated theory considers that bacterial genomes have millions of sites each and selection events on these many sites could interfere with each other, so that only larger effects would be important. However, bacteria can exchange genetic material, and in principle, this exchange could eliminate the interference between the evolution of the sites. In conclusion, we used simulations to confirm that during multisite evolution with realistic levels of recombination, only larger effects are important. We propose that advantages of less than 10 -7are effectively neutral.« less

  15. Weakly Deleterious Mutations and Low Rates of Recombination Limit the Impact of Natural Selection on Bacterial Genomes

    DOE PAGES

    Price, Morgan N.; Arkin, Adam P.

    2015-12-15

    Free-living bacteria are usually thought to have large effective population sizes, and so tiny selective differences can drive their evolution. However, because recombination is infrequent, “background selection” against slightly deleterious alleles should reduce the effective population size (N e) by orders of magnitude. For example, for a well-mixed population with 10 12 individuals and a typical level of homologous recombination (r/m= 3, i.e., nucleotide changes due to recombination [r] occur at 3 times the mutation rate [m]), we predict that N e is<10 7. An argument for high N e values for bacteria has been the high genetic diversity withinmore » many bacterial “species,” but this diversity may be due to population structure: diversity across subpopulations can be far higher than diversity within a subpopulation, which makes it difficult to estimate N e correctly. Given an estimate ofN e, standard population genetics models imply that selection should be sufficient to drive evolution if N e ×s is >1, where s is the selection coefficient. We found that this remains approximately correct if background selection is occurring or when population structure is present. Overall, we predict that even for free-living bacteria with enormous populations, natural selection is only a significant force ifs is above 10 -7 or so. Because bacteria form huge populations with trillions of individuals, the simplest theoretical prediction is that the better allele at a site would predominate even if its advantage was just 10 -9 per generation. In other words, virtually every nucleotide would be at the local optimum in most individuals. A more sophisticated theory considers that bacterial genomes have millions of sites each and selection events on these many sites could interfere with each other, so that only larger effects would be important. However, bacteria can exchange genetic material, and in principle, this exchange could eliminate the interference between the evolution of the sites. In conclusion, we used simulations to confirm that during multisite evolution with realistic levels of recombination, only larger effects are important. We propose that advantages of less than 10 -7are effectively neutral.« less

  16. Film and Visual Perception

    ERIC Educational Resources Information Center

    Giltrow, David

    1978-01-01

    One practical method which development film makers can adopt to increase comprehension of important scenes is to eliminate extraneous background information by putting it out of focus, or by shooting against plain backgrounds. (Author/STS)

  17. Rare Earth Fluorescent Nanomaterials for Enhanced Development of Latent Fingerprints.

    PubMed

    Wang, Meng; Li, Ming; Yu, Aoyang; Wu, Jian; Mao, Chuanbin

    2015-12-30

    The most commonly found fingerprints at crime scenes are latent and, thus, an efficient method for detecting latent fingerprints is very important. However, traditional developing techniques have drawbacks such as low developing sensitivity, high background interference, complicated operation, and high toxicity. To tackle this challenge, we have synthesized two kinds of rare earth fluorescent nanomaterials, including the fluoresce red-emitting YVO4:Eu nanocrystals and green-emitting LaPO4:Ce,Tb nanobelts, and then used them as fluorescent labels for the development of latent fingerprints with high sensitivity, high contrast, high selectivity, high efficiency, and low background interference, on various substrates including noninfiltrating materials, semi-infiltrating materials, and infiltrating materials.

  18. Matrix interference from Fc-Fc interactions in immunoassays for detecting human IgG4 therapeutics.

    PubMed

    Partridge, Michael A; Karayusuf, Elif Kabuloglu; Dhulipala, Gangadhar; Dreyer, Robert; Daly, Thomas; Sumner, Giane; Pyles, Erica; Torri, Albert

    2015-01-01

    An assay measuring an IgG4 biotherapeutic in human serum used a drug-specific monoclonal antibody (mAb) capture reagent and an antihuman IgG4 mAb as detection reagent. However, serum IgG4 binding to the capture mAb via Fc-interactions was detected by the anti-IgG4 mAb, causing high background. Two approaches were developed to minimize background; incorporating a mild acid sample preparation step or using the Fab of the capture antibody. Either strategy improved signal:noise dramatically, increasing assay sensitivity >20-fold. Biophysical analyses of antibody domains indicated that noncovalent Fc oligomers could inhibit the background. Matrix interference from human IgG4 binding to the capture mAb was reduced with a Fab fragment of the drug-specific capture antibody or by incorporating a mild acid sample treatment into the assay.

  19. Modulated Fourier Transform Raman Fiber-Optic Spectroscopy

    NASA Technical Reports Server (NTRS)

    Jensen, Brian J. (Inventor); Cooper, John B. (Inventor); Wise, Kent L. (Inventor)

    2000-01-01

    A modification to a commercial Fourier Transform (FT) Raman spectrometer is presented for the elimination of thermal backgrounds in the FT Raman spectra. The modification involves the use of a mechanical optical chopper to modulate the continuous wave laser, remote collection of the signal via fiber optics, and connection of a dual-phase digital-signal-processor (DSP) lock-in amplifier between the detector and the spectrometer's collection electronics to demodulate and filter the optical signals. The resulting Modulated Fourier Transform Raman Fiber-Optic Spectrometer is capable of completely eliminating thermal backgrounds at temperatures exceeding 300 C.

  20. Identification of algae which interfere with the detection of Giardia cysts and Cryptosporidium oocysts and a method for alleviating this interference.

    PubMed Central

    Rodgers, M R; Flanigan, D J; Jakubowski, W

    1995-01-01

    Fifty-four algal species were tested for cross-reaction in the American Society for Testing and Materials Giardia/Cryptosporidium indirect immunofluorescence assay, and 24 showed some degree of fluorescence. Two species, Navicula minima and Synechococcus elongatus, exhibited a bright apple green fluorescence. The addition of goat serum to the assay mixture blocked the fluorescence of most nontarget organisms tested and also decreased the background fluorescence. Goat serum did not interfere with the fluorescence of Giardia cysts or Cryptosporidium oocysts or the identification of cyst and oocyst internal structures. PMID:7487013

  1. Measurements of a potential interference with laser-induced fluorescence measurements of ambient OH from the ozonolysis of biogenic alkenes

    NASA Astrophysics Data System (ADS)

    Rickly, Pamela; Stevens, Philip S.

    2018-01-01

    Reactions of the hydroxyl radical (OH) play a central role in the chemistry of the atmosphere, and measurements of its concentration can provide a rigorous test of our understanding of atmospheric oxidation. Several recent studies have shown large discrepancies between measured and modeled OH concentrations in forested areas impacted by emissions of biogenic volatile organic compounds (BVOCs), where modeled concentrations were significantly lower than measurements. A potential reason for some of these discrepancies involves interferences associated with the measurement of OH using the laser-induced fluorescence-fluorescence assay by gas expansion (LIF-FAGE) technique in these environments. In this study, a turbulent flow reactor operating at atmospheric pressure was coupled to a LIF-FAGE cell and the OH signal produced from the ozonolysis of α-pinene, β-pinene, ocimene, isoprene, and 2-methyl-3-buten-2-ol (MBO) was measured. To distinguish between OH produced from the ozonolysis reactions and any OH artifact produced inside the LIF-FAGE cell, an external chemical scrubbing technique was used, allowing for the direct measurement of any interference. An interference under high ozone (between 2 × 1013 and 10 × 1013 cm-3) and BVOC concentrations (between approximately 0.1 × 1012 and 40 × 1012 cm-3) was observed that was not laser generated and was independent of the ozonolysis reaction time. For the ozonolysis of α- and β-pinene, the observed interference accounted for approximately 40 % of the total OH signal, while for the ozonolysis of ocimene the observed interference accounted for approximately 70 % of the total OH signal. Addition of acetic acid to the reactor eliminated the interference, suggesting that the source of the interference in these experiments involved the decomposition of stabilized Criegee intermediates (SCIs) inside the FAGE detection cell. Extrapolation of these measurements to ambient concentrations suggests that these interferences should be below the detection limit of the instrument.

  2. How resonance-continuum interference changes 750 GeV diphoton excess: Signal enhancement and peak shift

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jung, Sunghoon; Song, Jeonghyeon; Yoon, Yeo Woong

    2016-05-02

    A hypothetical new scalar resonance, a candidate explanation for the recently observed 750 GeV diphoton excess at the LHC 13 TeV, necessarily interferes with the continuum background gg → γγ. The interference has two considerable effects: (1) enhancing or suppressing diphoton signal rate due to the imaginary-part interference and (2) distorting resonance shape due to the real-part interference. We study them based on the best-fit analysis of two benchmark models: two Higgs doublets with ~50 GeV width (exhibiting the imaginary-part interference effect) and a singlet scalar with 5 GeV width (exhibiting the real-part one), both extended with vector-like fermions. Furthermore,more » we find that the resonance contribution can be enhanced by a factor of 2 (1.6) for 3 (6) fb signal rate, or the 68% CL allowed mass region is shifted by O (1) GeV. If the best-fit excess rate decreases in the future data, the interference effects will become more significant.« less

  3. Interference effects between memory systems in the acquisition of a skill.

    PubMed

    Gagné, Marie-Hélène; Cohen, Henri

    2016-10-01

    There is now converging evidence that the declarative memory system (hippocampus dependent) contributes to sequential motor learning in concert with the procedural memory system (striatum dependent). Because of the competition for shared neuronal resources, introducing a declarative memory task can impair learning of a new motor sequence and interference may occur during the procedural consolidation process. Here, we investigated the extent to which interference effects between memory systems are seen at the retrieval phase of skill learning. Healthy participants were assigned to a control (n = 15) or a declarative condition (n = 15) and trained on a sequence of finger movements (FOS task). Both groups showed similar improvement at the end of the practice session on the first day. Twenty-four hours later, controls were tested solely on the FOS task, while subjects in the declarative condition first engaged in a visuospatial task. Additional offline gains in performance were observed only in the control condition. The introduction of a visuospatial memory task just before retrieval of the motor skill was sufficient to eliminate these gains. This suggests that interference between procedural and declarative memory systems may also occur during subsequent motor recall. It is proposed that the interference effects are linked, in part, to the spatial nature of the motor and declarative tasks, which specifically depends upon hippocampal involvement.

  4. Progress toward accurate high spatial resolution actinide analysis by EPMA

    NASA Astrophysics Data System (ADS)

    Jercinovic, M. J.; Allaz, J. M.; Williams, M. L.

    2010-12-01

    High precision, high spatial resolution EPMA of actinides is a significant issue for geochronology, resource geochemistry, and studies involving the nuclear fuel cycle. Particular interest focuses on understanding of the behavior of Th and U in the growth and breakdown reactions relevant to actinide-bearing phases (monazite, zircon, thorite, allanite, etc.), and geochemical fractionation processes involving Th and U in fluid interactions. Unfortunately, the measurement of minor and trace concentrations of U in the presence of major concentrations of Th and/or REEs is particularly problematic, especially in complexly zoned phases with large compositional variation on the micro or nanoscale - spatial resolutions now accessible with modern instruments. Sub-micron, high precision compositional analysis of minor components is feasible in very high Z phases where scattering is limited at lower kV (15kV or less) and where the beam diameter can be kept below 400nm at high current (e.g. 200-500nA). High collection efficiency spectrometers and high performance electron optics in EPMA now allow the use of lower overvoltage through an exceptional range in beam current, facilitating higher spatial resolution quantitative analysis. The U LIII edge at 17.2 kV precludes L-series analysis at low kV (high spatial resolution), requiring careful measurements of the actinide M series. Also, U-La detection (wavelength = 0.9A) requires the use of LiF (220) or (420), not generally available on most instruments. Strong peak overlaps of Th on U make highly accurate interference correction mandatory, with problems compounded by the ThMIV and ThMV absorption edges affecting peak, background, and interference calibration measurements (especially the interference of the Th M line family on UMb). Complex REE bearing phases such as monazite, zircon, and allanite have particularly complex interference issues due to multiple peak and background overlaps from elements present in the activation volume, as well as interferences from fluorescence at a distance from adjacent phases or distinct compositional domains in the same phase. Interference corrections for elements detected during boundary fluorescence are further complicated by X-ray focusing geometry considerations. Additional complications arise from the high current densities required for high spatial resolution and high count precision, such as fluctuations in internal charge distribution and peak shape changes as satellite production efficiency varies from calibration to analysis. No flawless method has yet emerged. Extreme care in interference corrections, especially where multiple and sometime mutual overlaps are present, and maximum care (and precision) in background characterization to account for interferences and curvature (e.g., WDS scan or multipoint regression), are crucial developments. Calibration curves from multiple peak and interference calibration measurements at different concentrations, and iterative software methodologies for incorporating absorption edge effects, and non-linearities in interference corrections due to peak shape changes and off-axis X-ray defocussing during boundary fluorescence at a distance, are directions with significant potential.

  5. 76 FR 22399 - Proposed Data Collections Submitted for Public Comment and Recommendations

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-21

    ... Severe Adverse Events Associated with Treatment of Latent Tuberculosis Infection--(0920-0773 exp. 04/31/ 2011)--Reinstatement with change--Division of Tuberculosis Elimination (DTBE), National Center for HIV... Prevention (CDC). Background and Brief Description As part of the national tuberculosis (TB) elimination...

  6. An Evolving Genetic Architecture Interacts with Hill–Robertson Interference to Determine the Benefit of Sex

    PubMed Central

    Whitlock, Alexander O. B.; Peck, Kayla M.; Azevedo, Ricardo B. R.; Burch, Christina L.

    2016-01-01

    Sex is ubiquitous in the natural world, but the nature of its benefits remains controversial. Previous studies have suggested that a major advantage of sex is its ability to eliminate interference between selection on linked mutations, a phenomenon known as Hill–Robertson interference. However, those studies may have missed both important advantages and important disadvantages of sexual reproduction because they did not allow the distributions of mutational effects and interactions (i.e., the genetic architecture) to evolve. Here we investigate how Hill–Robertson interference interacts with an evolving genetic architecture to affect the evolutionary origin and maintenance of sex by simulating evolution in populations of artificial gene networks. We observed a long-term advantage of sex—equilibrium mean fitness of sexual populations exceeded that of asexual populations—that did not depend on population size. We also observed a short-term advantage of sex—sexual modifier mutations readily invaded asexual populations—that increased with population size, as was observed in previous studies. We show that the long- and short-term advantages of sex were both determined by differences between sexual and asexual populations in the evolutionary dynamics of two properties of the genetic architecture: the deleterious mutation rate (Ud) and recombination load (LR). These differences resulted from a combination of selection to minimize LR, which is experienced only by sexuals, and Hill–Robertson interference experienced primarily by asexuals. In contrast to the previous studies, in which Hill–Robertson interference had only a direct impact on the fitness advantages of sex, the impact of Hill–Robertson interference in our simulations was mediated additionally by an indirect impact on the efficiency with which selection acted to reduce Ud. PMID:27098911

  7. Effect of electrode design on crosstalk between neighboring organic field-effect transistors based on one single crystal

    NASA Astrophysics Data System (ADS)

    Li, Mengjie; Tang, Qingxin; Tong, Yanhong; Zhao, Xiaoli; Zhou, Shujun; Liu, Yichun

    2018-03-01

    The design of high-integration organic circuits must be such that the interference between neighboring devices is eliminated. Here, rubrene crystals were used to study the effect of the electrode design on crosstalk between neighboring organic field-effect transistors (OFETs). Results show that a decreased source/drain interval and gate electrode width can decrease the diffraction distance of the current, and therefore can weaken the crosstalk. In addition, the inherent low carrier concentration in organic semiconductors can create a high-resistance barrier at the space between gate electrodes of neighboring devices, limiting or even eliminating the crosstalk as a result of the gate electrode width being smaller than the source/drain electrode width.

  8. The role of atomic absorption spectrometry in geochemical exploration

    USGS Publications Warehouse

    Viets, J.G.; O'Leary, R. M.

    1992-01-01

    In this paper we briefly describe the principles of atomic absorption spectrometry (AAS) and the basic hardware components necessary to make measurements of analyte concentrations. Then we discuss a variety of methods that have been developed for the introduction of analyte atoms into the light path of the spectrophotometer. This section deals with sample digestion, elimination of interferences, and optimum production of ground-state atoms, all critical considerations when choosing an AAS method. Other critical considerations are cost, speed, simplicity, precision, and applicability of the method to the wide range of materials sampled in geochemical exploration. We cannot attempt to review all of the AAS methods developed for geological materials but instead will restrict our discussion to some of those appropriate for geochemical exploration. Our background and familiarity are reflected in the methods we discuss, and we have no doubt overlooked many good methods. Our discussion should therefore be considered a starting point in finding the right method for the problem, rather than the end of the search. Finally, we discuss the future of AAS relative to other instrumental techniques and the promising new directions for AAS in geochemical exploration. ?? 1992.

  9. Characterization of Polymer Blends: Optical Microscopy (*Polarized, Interference and Phase Contrast Microscopy*) and Confocal Microscopy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ramanathan, Nathan Muruganathan; Darling, Seth B.

    2015-01-01

    Chapter 15 surveys the characterization of macro, micro and meso morphologies of polymer blends by optical microscopy. Confocal Microscopy offers the ability to view the three dimensional morphology of polymer blends, popular in characterization of biological systems. Confocal microscopy uses point illumination and a spatial pinhole to eliminate out-of focus light in samples that are thicker than the focal plane.

  10. Air and Bone Conduction Thresholds of Deaf and Normal Hearing Subjects before and during the Elimination of Cutaneous-Tactile Interference with Anesthesia. Final Report.

    ERIC Educational Resources Information Center

    Nober, E. Harris

    The study investigated whether low frequency air and bone thresholds elicited at high intensity levels from deaf children with a sensory-neural diagnosis reflect valid auditory sensitivity or are mediated through cutaneous-tactile receptors. Subjects were five totally deaf (mean age 17.0) yielding vibrotactile thresholds but with no air and bone…

  11. A sensitive chemiluminescence enzyme immunoassay based on molecularly imprinted polymers solid-phase extraction of parathion.

    PubMed

    Chen, Ge; Jin, Maojun; Du, Pengfei; Zhang, Chan; Cui, Xueyan; Zhang, Yudan; She, Yongxin; Shao, Hua; Jin, Fen; Wang, Shanshan; Zheng, Lufei; Wang, Jing

    2017-08-01

    The chemiluminescence enzyme immunoassay (CLEIA) method responds differently to various sample matrices because of the matrix effect. In this work, the CLEIA method was coupled with molecularly imprinted polymers (MIPs) synthesized by precipitation polymerization to study the matrix effect. The sample recoveries ranged from 72.62% to 121.89%, with a relative standard deviation (RSD) of 3.74-18.14%.The ratio of the sample matrix-matched standard curve slope rate to the solvent standard curve slope was 1.21, 1.12, 1.17, and 0.85 for apple, rice, orange and cabbage in samples pretreated with the mixture of PSA and C 18 . However, the ratio of sample (apple, rice, orange, and cabbage) matrix-matched standard-MIPs curve slope rate to the solvent standard curve was 1.05, 0.92, 1.09, and 1.05 in samples pretreated with MIPs, respectively. The results demonstrated that the matrices of the samples greatly interfered with the detection of parathion residues by CLEIA. The MIPs bound specifically to the parathion in the samples and eliminated the matrix interference effect. Therefore, the CLEIA method have successfully applied MIPs in sample pretreatment to eliminate matrix interference effects and provided a new sensitive assay for agro-products. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Reduced background autofluorescence for cell imaging using nanodiamonds and lanthanide chelates.

    PubMed

    Cordina, Nicole M; Sayyadi, Nima; Parker, Lindsay M; Everest-Dass, Arun; Brown, Louise J; Packer, Nicolle H

    2018-03-14

    Bio-imaging is a key technique in tracking and monitoring important biological processes and fundamental biomolecular interactions, however the interference of background autofluorescence with targeted fluorophores is problematic for many bio-imaging applications. This study reports on two novel methods for reducing interference with cellular autofluorescence for bio-imaging. The first method uses fluorescent nanodiamonds (FNDs), containing nitrogen vacancy centers. FNDs emit at near-infrared wavelengths typically higher than most cellular autofluorescence; and when appropriately functionalized, can be used for background-free imaging of targeted biomolecules. The second method uses europium-chelating tags with long fluorescence lifetimes. These europium-chelating tags enhance background-free imaging due to the short fluorescent lifetimes of cellular autofluorescence. In this study, we used both methods to target E-selectin, a transmembrane glycoprotein that is activated by inflammation, to demonstrate background-free fluorescent staining in fixed endothelial cells. Our findings indicate that both FND and Europium based staining can improve fluorescent bio-imaging capabilities by reducing competition with cellular autofluorescence. 30 nm nanodiamonds coated with the E-selectin antibody was found to enable the most sensitive detective of E-selectin in inflamed cells, with a 40-fold increase in intensity detected.

  13. Digital simulation of hybrid loop operation in RFI backgrounds.

    NASA Technical Reports Server (NTRS)

    Ziemer, R. E.; Nelson, D. R.

    1972-01-01

    A digital computer model for Monte-Carlo simulation of an imperfect second-order hybrid phase-locked loop (PLL) operating in radio-frequency interference (RFI) and Gaussian noise backgrounds has been developed. Characterization of hybrid loop performance in terms of cycle slipping statistics and phase error variance, through computer simulation, indicates that the hybrid loop has desirable performance characteristics in RFI backgrounds over the conventional PLL or the costas loop.

  14. Influence of detector noise and background noise on detection-system

    NASA Astrophysics Data System (ADS)

    Song, Yiheng; Wang, Zhiyong

    2018-02-01

    Study the noise by detectors and background light ,we find that the influence of background noise on the detection is more than that of itself. Therefore, base on the fiber coupled beam splitting technique, the small area detector is used to replace the large area detector. It can achieve high signal-to-noise ratio (SNR) and reduce the speckle interference of the background light. This technique is expected to solve the bottleneck of large field of view and high sensitivity.

  15. Public access defibrillation: suppression of 16.7 Hz interference generated by the power supply of the railway systems.

    PubMed

    Christov, Ivaylo I; Iliev, Georgi L

    2005-03-15

    A specific problem using the public access defibrillators (PADs) arises at the railway stations. Some countries as Germany, Austria, Switzerland, Norway and Sweden are using AC railroad net power-supply system with rated 16.7 Hz frequency modulated from 15.69 Hz to 17.36 Hz. The power supply frequency contaminates the electrocardiogram (ECG). It is difficult to be suppressed or eliminated due to the fact that it considerably overlaps the frequency spectra of the ECG. The interference impedes the automated decision of the PADs whether a patient should be (or should not be) shocked. The aim of this study is the suppression of the 16.7 Hz interference generated by the power supply of the railway systems. Software solution using adaptive filtering method was proposed for 16.7 Hz interference suppression. The optimal performance of the filter is achieved, embedding a reference channel in the PADs to record the interference. The method was tested with ECGs from AHA database. The method was tested with patients of normal sinus rhythms, symptoms of tachycardia and ventricular fibrillation. Simulated interference with frequency modulation from 15.69 Hz to 17.36 Hz changing at a rate of 2% per second was added to the ECGs, and then processed by the suggested adaptive filtering. The method totally suppresses the noise with no visible distortions of the original signals. The proposed adaptive filter for noise suppression generated by the power supply of the railway systems has a simple structure requiring a low level of computational resources, but a good reference signal as well.

  16. Biodegradable lipids enabling rapidly eliminated lipid nanoparticles for systemic delivery of RNAi therapeutics.

    PubMed

    Maier, Martin A; Jayaraman, Muthusamy; Matsuda, Shigeo; Liu, Ju; Barros, Scott; Querbes, William; Tam, Ying K; Ansell, Steven M; Kumar, Varun; Qin, June; Zhang, Xuemei; Wang, Qianfan; Panesar, Sue; Hutabarat, Renta; Carioto, Mary; Hettinger, Julia; Kandasamy, Pachamuthu; Butler, David; Rajeev, Kallanthottathil G; Pang, Bo; Charisse, Klaus; Fitzgerald, Kevin; Mui, Barbara L; Du, Xinyao; Cullis, Pieter; Madden, Thomas D; Hope, Michael J; Manoharan, Muthiah; Akinc, Akin

    2013-08-01

    In recent years, RNA interference (RNAi) therapeutics, most notably with lipid nanoparticle-based delivery systems, have advanced into human clinical trials. The results from these early clinical trials suggest that lipid nanoparticles (LNPs), and the novel ionizable lipids that comprise them, will be important materials in this emerging field of medicine. A persistent theme in the use of materials for biomedical applications has been the incorporation of biodegradability as a means to improve biocompatibility and/or to facilitate elimination. Therefore, the aim of this work was to further advance the LNP platform through the development of novel, next-generation lipids that combine the excellent potency of the most advanced lipids currently available with biodegradable functionality. As a representative example of this novel class of biodegradable lipids, the lipid evaluated in this work displays rapid elimination from plasma and tissues, substantially improved tolerability in preclinical studies, while maintaining in vivo potency on par with that of the most advanced lipids currently available.

  17. Dual function microscope for quantitative DIC and birefringence imaging

    NASA Astrophysics Data System (ADS)

    Li, Chengshuai; Zhu, Yizheng

    2016-03-01

    A spectral multiplexing interferometry (SXI) method is presented for integrated birefringence and phase gradient measurement on label-free biological specimens. With SXI, the retardation and orientation of sample birefringence are simultaneously encoded onto two separate spectral carrier waves, generated by a crystal retarder oriented at a specific angle. Thus sufficient information for birefringence determination can be obtained from a single interference spectrum, eliminating the need for multiple acquisitions with mechanical rotation or electrical modulation. In addition, with the insertion of a Nomarski prism, the setup can then acquire quantitative differential interference contrast images. Red blood cells infected by malaria parasites are imaged for birefringence retardation as well as phase gradient. The results demonstrate that the SXI approach can achieve both quantitative phase imaging and birefringence imaging with a single, high-sensitivity system.

  18. Charge qubit coupled to an intense microwave electromagnetic field in a superconducting Nb device: evidence for photon-assisted quasiparticle tunneling.

    PubMed

    de Graaf, S E; Leppäkangas, J; Adamyan, A; Danilov, A V; Lindström, T; Fogelström, M; Bauch, T; Johansson, G; Kubatkin, S E

    2013-09-27

    We study a superconducting charge qubit coupled to an intensive electromagnetic field and probe changes in the resonance frequency of the formed dressed states. At large driving strengths, exceeding the qubit energy-level splitting, this reveals the well known Landau-Zener-Stückelberg interference structure of a longitudinally driven two-level system. For even stronger drives, we observe a significant change in the Landau-Zener-Stückelberg pattern and contrast. We attribute this to photon-assisted quasiparticle tunneling in the qubit. This results in the recovery of the qubit parity, eliminating effects of quasiparticle poisoning, and leads to an enhanced interferometric response. The interference pattern becomes robust to quasiparticle poisoning and has a good potential for accurate charge sensing.

  19. Bayesian modelling of the emission spectrum of the Joint European Torus Lithium Beam Emission Spectroscopy system.

    PubMed

    Kwak, Sehyun; Svensson, J; Brix, M; Ghim, Y-C

    2016-02-01

    A Bayesian model of the emission spectrum of the JET lithium beam has been developed to infer the intensity of the Li I (2p-2s) line radiation and associated uncertainties. The detected spectrum for each channel of the lithium beam emission spectroscopy system is here modelled by a single Li line modified by an instrumental function, Bremsstrahlung background, instrumental offset, and interference filter curve. Both the instrumental function and the interference filter curve are modelled with non-parametric Gaussian processes. All free parameters of the model, the intensities of the Li line, Bremsstrahlung background, and instrumental offset, are inferred using Bayesian probability theory with a Gaussian likelihood for photon statistics and electronic background noise. The prior distributions of the free parameters are chosen as Gaussians. Given these assumptions, the intensity of the Li line and corresponding uncertainties are analytically available using a Bayesian linear inversion technique. The proposed approach makes it possible to extract the intensity of Li line without doing a separate background subtraction through modulation of the Li beam.

  20. Co-detection: ultra-reliable nanoparticle-based electrical detection of biomolecules in the presence of large background interference.

    PubMed

    Liu, Yang; Gu, Ming; Alocilja, Evangelyn C; Chakrabartty, Shantanu

    2010-11-15

    An ultra-reliable technique for detecting trace quantities of biomolecules is reported. The technique called "co-detection" exploits the non-linear redundancy amongst synthetically patterned biomolecular logic circuits for deciphering the presence or absence of target biomolecules in a sample. In this paper, we verify the "co-detection" principle on gold-nanoparticle-based conductimetric soft-logic circuits which use a silver-enhancement technique for signal amplification. Using co-detection, we have been able to demonstrate a great improvement in the reliability of detecting mouse IgG at concentration levels that are 10(5) lower than the concentration of rabbit IgG which serves as background interference. Copyright © 2010 Elsevier B.V. All rights reserved.

  1. Far-field detection of sub-wavelength Tetris without extra near-field metal parts based on phase prints of time-reversed fields with intensive background interference.

    PubMed

    Chen, Yingming; Wang, Bing-Zhong

    2014-07-14

    Time-reversal (TR) phase prints are first used in far-field (FF) detection of sub-wavelength (SW) deformable scatterers without any extra metal structure positioned in the vicinity of the target. The 2D prints derive from discrete short-time Fourier transform of 1D TR electromagnetic (EM) signals. Because the time-invariant intensive background interference is effectively centralized by TR technique, the time-variant weak indication from FF SW scatterers can be highlighted. This method shows a different use of TR technique in which the focus peak of TR EM waves is unusually removed and the most useful information is conveyed by the other part.

  2. An Efficient Multistrategy DNA Decontamination Procedure of PCR Reagents for Hypersensitive PCR Applications

    PubMed Central

    Pruvost, Mélanie; Bennett, E. Andrew; Grange, Thierry; Geigl, Eva-Maria

    2010-01-01

    Background PCR amplification of minute quantities of degraded DNA for ancient DNA research, forensic analyses, wildlife studies and ultrasensitive diagnostics is often hampered by contamination problems. The extent of these problems is inversely related to DNA concentration and target fragment size and concern (i) sample contamination, (ii) laboratory surface contamination, (iii) carry-over contamination, and (iv) contamination of reagents. Methodology/Principal Findings Here we performed a quantitative evaluation of current decontamination methods for these last three sources of contamination, and developed a new procedure to eliminate contaminating DNA contained in PCR reagents. We observed that most current decontamination methods are either not efficient enough to degrade short contaminating DNA molecules, rendered inefficient by the reagents themselves, or interfere with the PCR when used at doses high enough to eliminate these molecules. We also show that efficient reagent decontamination can be achieved by using a combination of treatments adapted to different reagent categories. Our procedure involves γ- and UV-irradiation and treatment with a mutant recombinant heat-labile double-strand specific DNase from the Antarctic shrimp Pandalus borealis. Optimal performance of these treatments is achieved in narrow experimental conditions that have been precisely analyzed and defined herein. Conclusions/Significance There is not a single decontamination method valid for all possible contamination sources occurring in PCR reagents and in the molecular biology laboratory and most common decontamination methods are not efficient enough to decontaminate short DNA fragments of low concentration. We developed a versatile multistrategy decontamination procedure for PCR reagents. We demonstrate that this procedure allows efficient reagent decontamination while preserving the efficiency of PCR amplification of minute quantities of DNA. PMID:20927390

  3. Quantitative interference by cysteine and N-acetylcysteine metabolites during the LC-MS/MS bioanalysis of a small molecule.

    PubMed

    Barricklow, Jason; Ryder, Tim F; Furlong, Michael T

    2009-08-01

    During LC-MS/MS quantification of a small molecule in human urine samples from a clinical study, an unexpected peak was observed to nearly co-elute with the analyte of interest in many study samples. Improved chromatographic resolution revealed the presence of at least 3 non-analyte peaks, which were identified as cysteine metabolites and N-acetyl (mercapturic acid) derivatives thereof. These metabolites produced artifact responses in the parent compound MRM channel due to decomposition in the ionization source of the mass spectrometer. Quantitative comparison of the analyte concentrations in study samples using the original chromatographic method and the improved chromatographic separation method demonstrated that the original method substantially over-estimated the analyte concentration in many cases. The substitution of electrospray ionization (ESI) for atmospheric pressure chemical ionization (APCI) nearly eliminated the source instability of these metabolites, which would have mitigated their interference in the quantification of the analyte, even without chromatographic separation. These results 1) demonstrate the potential for thiol metabolite interferences during the quantification of small molecules in pharmacokinetic samples, and 2) underscore the need to carefully evaluate LC-MS/MS methods for molecules that can undergo metabolism to thiol adducts to ensure that they are not susceptible to such interferences during quantification.

  4. On-line removal of redox-active interferents by a porous electrode before amperometric blood glucose determination.

    PubMed

    Deng, Chunyan; Peng, Yong; Su, Lei; Liu, You-Nian; Zhou, Feimeng

    2012-03-16

    A porous reticulated vitreous carbon (RVC) electrode and a disk electrode coupled in tandem in an electrochemical flow cell has been used for electrolytic removal of interferents before amperometric glucose detection. The electrolytic efficiency at the upstream RVC electrode is 100% at a flow rate of 0.1 mL min(-1) or lower. Potential interferents such as acetaminophen, ascorbic acid, and uric acid can be completely eliminated by electrolysis at the RVC electrode. A mixed monolayer comprising glucose oxidase (GOD) and ferrocenyl-1-undecanethiol preformed at the downstream gold disk electrode was used as a mediator-based amperometric glucose sensor. The dependence of the amperometric current on the glucose concentration exhibits good linearity across over three orders of magnitude. The glucose measurements were also found to be reproducible (RSD<3.5%) and accurate. Unlike the chemiluminescence method, this device obviates the use of carcinogenic substrates and the glucose sensor performance is independent of the oxygen present in sample. On the basis that the RVC electrode requires minimal cleanup and the GOD-modified electrode remains stable for a week, the electrochemical flow cell should be amenable for automated on-line removal of redox interferents for other types of enzyme-based biosensors. Copyright © 2012 Elsevier B.V. All rights reserved.

  5. Declarations of War and Authorizations for the Use of Military Force: Historical Background and Legal Implications

    DTIC Science & Technology

    2006-08-11

    the prohibition on recalling certain categories of retired officers to active duty “ in time of war or of national emergency...tend to endanger the security of naval operations in the war, or would tend to interfere with those operations, all further proceedings in the suit...manner that would interfere with their use “ in time of war or national emergency, by other units of the armed

  6. Discrimination of Biological and Chemical Threat Simulants in Residue Mixtures on Multiple Substrates

    DTIC Science & Technology

    2011-02-18

    environmental interferents selected for this study included dolomitic limestone (Lime, NIST Standard Reference Materials, Catalog No. SRM 88b) and ovalbumin...emission lines due solely to substrates or interferents can be ignored. As in previous studies by our group, the background-corrected peak ...calculated by adding the intensi- ties of the emission lines at 486 and 656 nm); the summed intensities were normalized to the total peak intensity of the

  7. Automatic circuit interrupter

    NASA Technical Reports Server (NTRS)

    Dwinell, W. S.

    1979-01-01

    In technique, voice circuits connecting crew's cabin to launch station through umbilical connector disconnect automatically unused, or deadened portion of circuits immediately after vehicle is launched, eliminating possibility that unused wiring interferes with voice communications inside vehicle or need for manual cutoff switch and its associated wiring. Technique is applied to other types of electrical actuation circuits, also launch of mapped vehicles, such as balloons, submarines, test sleds, and test chambers-all requiring assistance of ground crew.

  8. Eliminating Late Recurrence to Eradicate Breast Cancer

    DTIC Science & Technology

    2015-09-01

    induction of autophagy and antioxidant responses in Drosophila melanogaster . PLoS Genet. 9, e1003664 34 Rouschop, K.M. et al. (2010) The unfolded protein... genomic editing in human cells [8]. In contrast to RNA interference, CRISPR results in stable genetic changes in cell lines. We have generated the ...upcoming year. Since subtask 1d was delayed to pursue studies in the   Fig 2. CRISP/Cas9-Mediated Genomic Deletion of cATGs. Top: Construct

  9. Application of a simple column-switching ion chromatography technique for removal of matrix interferences and sensitive fluorescence determination of acidic compounds (pharmaceutical drugs) in complex samples.

    PubMed

    Muhammad, Nadeem; Subhani, Qamar; Wang, Fenglian; Guo, Dandan; Zhao, Qiming; Wu, Shuchao; Zhu, Yan

    2017-09-15

    This work illustrates the introduction of a simple, rugged and flexible column-switching ion chromatography (IC) technique for an automated on-line QuEChERS extracted samples extracts washing followed by sensitive fluorescence (FLD) determination of five acidic pharmaceutical drugs namely; clofibric acid (CLO), ibuprofen (IBU), aspirin (ASP), naproxen (NAP) and flurobrofen (FLU) in three complex samples (spinach, apple and hospital sewage sludge). An old anion exchange column IonPac ® AS11-HC was utilized as a pre-treatment column for on-line washing of inorganic and organic interferences followed by isocratic separation of five acidic drugs with another anion exchange IonPac ® AS12A analytical column by exploiting the column-switching technique. This novel method exhibited good linearity with correlation coefficients (r 2 ) for all drugs were in the range 0.976-0.996. The limit of detection and quantification of all five acidic drugs were in the range 0.024μg/kg to 8.70μg/kg and 0.082μg/kg to 0.029mg/kg, respectively, and better recoveries in the range 81.17-112.5% with percentage relative standard deviations (RSDs) less than 17.8% were obtained. This on-line sample pre-treatment method showed minimum matrix effect in the range of 0.87-1.25 except for aspirin. This simple rugged and flexible column-switching system required only 28min for maximum elimination of matrices and interferences in three complex samples extracts, isocratic separation of five acidic drugs and for the continuous regeneration of pre-treatment column prior to every subsequent analysis. Finally, this simple automated IC system was appeared so rugged and flexible, which can eliminate and wash out most of interference, impurities and matrices in complex samples, simply by adjusting the NaOH and acetonitrile concentration in washing mobile phase with maximum recoveries of acidic analytes of interest. Copyright © 2017. Published by Elsevier B.V.

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carena, Marcela; Liu, Zhen

    Heavy scalar and pseudoscalar resonance searches through themore » $$gg\\rightarrow S\\rightarrow t\\bar t$$ process are challenging due to the peculiar behavior of the large interference effects with the standard model $$t\\bar t$$ background. Such effects generate non-trivial lineshapes from additional relative phases between the signal and background amplitudes. We provide the analytic expressions for the differential cross sections to understand the interference effects in the heavy scalar signal lineshapes. We extend our study to the case of CP-violation and further consider the effect of bottom quarks in the production and decay processes. We also evaluate the contributions from additional particles to the gluon fusion production process, such as stops and vector-like quarks, that could lead to significant changes in the behavior of the signal lineshapes. Taking into account the large interference effects, we perform lineshape searches at the LHC and discuss the importance of the systematic uncertainties and smearing effects. Lastly, we present projected sensitivities for two LHC performance scenarios to probe the $$gg\\rightarrow S \\rightarrow t\\bar t$$ channel in various models.« less

  11. Accelerator mass spectrometry of strontium-90 for homeland security, environmental monitoring and human health

    NASA Astrophysics Data System (ADS)

    Tumey, Scott J.; Brown, Thomas A.; Hamilton, Terry E.; Hillegonds, Darren J.

    2008-05-01

    Strontium-90 is one of the most hazardous materials managed by agencies charged with protecting the public from radiation. Traditional radiometric methods have been limited by low sample throughput and slow turnaround times. Mass spectrometry offers the advantage of shorter analysis times and the ability to measure samples immediately after processing, however conventional mass spectrometric techniques are susceptible to molecular isobaric interferences that limit their overall sensitivity. In contrast, accelerator mass spectrometry is insensitive to molecular interferences and we have therefore begun developing a method for determination of 90Sr by accelerator mass spectrometry. Despite a pervasive interference from 90Zr, our initial development has yielded an instrumental background of ∼108 atoms (75 mBq) per sample. Further refinement of our system (e.g. redesign of our detector, use of alternative target materials) is expected to push the background below 106 atoms, close to the theoretical limit for AMS. Once we have refined our system and developed suitable sample preparation protocols, we will utilize our capability in applications to homeland security, environmental monitoring and human health.

  12. Matrix isolation with an ion transfer device for interference-free simultaneous spectrophotometric determinations of hexavalent and trivalent chromium in a flow-based system.

    PubMed

    Ohira, Shin-Ichi; Nakamura, Koretaka; Chiba, Mitsuki; Dasgupta, Purnendu K; Toda, Kei

    2017-03-01

    Chromium speciation by spectrophotometric determination of hexavalent chromium (Cr(VI)) with diphenylcarbazide (DPC) has several problems. These include: (1) the inability to directly detect trivalent chromium (Cr(III)) with DPC, (2) positive interference in Cr(VI) determination by other metal cations and (3) negative interference by any reducing agent present in the sample. These are addressed with an ion transfer device (ITD) in a flow injection analysis system. We previously developed the ITD for electrodialytic separations. Here we separate oppositely charged Cr(III) and Cr(VI) species by the ITD into two different acceptor solutions within ~5 s. The acceptor solutions consist of buffered H 2 O 2 to oxidize the Cr(III) to Cr(VI). Then DPC is added to either acceptor to measure Cr(III) and Cr(VI) spectrophotometrically. The system was optimized to provide the same response for Cr(VI) and Cr(III) with limits of detection (LODs, S/N=3) of 0.5 μg L -1 for each and a throughput rate of 30 samples h -1 . The ITD separation was also effective for matrix isolation and reduction of interferences. Potential cationic interferences were not transferred into the anionic Cr(VI) acceptor stream. Much of the organic compounds in soil extracts were also eliminated as evidenced from standard addition and recovery studies. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. High-sensitivity interference-free diagnostic for measurement of methane in shock tubes

    NASA Astrophysics Data System (ADS)

    Sur, Ritobrata; Wang, Shengkai; Sun, Kai; Davidson, David F.; Jeffries, Jay B.; Hanson, Ronald K.

    2015-05-01

    A sensitive CW laser absorption diagnostic for in-situ measurement of methane mole fraction at high temperatures is developed. The selected transitions for the diagnostic are a cluster of lines near 3148.8 cm-1 from the R-branch of the ν3 band of the CH4 absorption spectrum. The selected transitions have 2-3 times more sensitivity to CH4 concentration than the P-branch in the 3.3 μm region, lower interference from major interfering intermediate species in most hydrocarbon reactions, and applicability over a wide range of pressures and temperatures. Absorption cross-sections for a broad collection of hydrocarbons were simulated to evaluate interference absorption, and were generally found to be negligible near 3148.8 cm-1. However, minor interference from hot bands of C2H2 and C2H4 was observed and was characterized experimentally, revealing a weak dependence on wavelength. To eliminate such interferences, a two-color on-line and off-line measurement scheme is proposed to determine CH4 concentration. The colors selected, i.e., for on-line (3148.81 cm-1) and off-line (3148.66 cm-1), are characterized between 0.2-4 atm and 500 K-2100 K by absorption coefficient measurements in a shock tube. Minimum detectable levels of CH4 in shock tube experiments are reported for this range of temperatures and pressures. An example measurement is shown for sensitive detection of CH4 in a shock tube chemical kinetics experiment.

  14. Elimination of 'ghost'-effect-related systematic error in metrology of X-ray optics with a long trace profiler

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yashchuk, Valeriy V.; Irick, Steve C.; MacDowell, Alastair A.

    2005-04-28

    A data acquisition technique and relevant program for suppression of one of the systematic effects, namely the ''ghost'' effect, of a second generation long trace profiler (LTP) is described. The ''ghost'' effect arises when there is an unavoidable cross-contamination of the LTP sample and reference signals into one another, leading to a systematic perturbation in the recorded interference patterns and, therefore, a systematic variation of the measured slope trace. Perturbations of about 1-2 {micro}rad have been observed with a cylindrically shaped X-ray mirror. Even stronger ''ghost'' effects show up in an LTP measurement with a mirror having a toroidal surfacemore » figure. The developed technique employs separate measurement of the ''ghost''-effect-related interference patterns in the sample and the reference arms and then subtraction of the ''ghost'' patterns from the sample and the reference interference patterns. The procedure preserves the advantage of simultaneously measuring the sample and reference signals. The effectiveness of the technique is illustrated with LTP metrology of a variety of X-ray mirrors.« less

  15. Solid cation exchange phase to remove interfering anthocyanins in the analysis of other bioactive phenols in red wine.

    PubMed

    da Silva, Letícia Flores; Guerra, Celito Crivellaro; Klein, Diandra; Bergold, Ana Maria

    2017-07-15

    Bioactive phenols (BPs) are often targets in red wine analysis. However, other compounds interfere in the liquid chromatography methods used for this analysis. Here, purification procedures were tested to eliminate anthocyanin interference during the determination of 19 red-wine BPs. Liquid chromatography, coupled to a diode array detector (HPLC-DAD) and a mass spectrometer (UPLC-MS), was used to compare the direct injection of the samples with solid-phase extractions: reversed-phase (C18) and strong cation-exchange (SCX). The HPLC-DAD method revealed that, out of 13BPs, only six are selectively analyzed with or without C18 treatment, whereas SCX enabled the detection of all BPs. The recovery with SCX was above 86.6% for eight BPs. Moreover, UPLC-MS demonstrated the potential of SCX sample preparation for the determination of 19BPs. The developed procedure may be extended to the analysis of other red wine molecules or to other analytical methods where anthocyanins may interfere. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Catalytic determination of vanadium in water

    USGS Publications Warehouse

    Fishman, M. J.; Skougstad, M.W.

    1964-01-01

    A rapid, accurate, and sensitive spectrophotometric method for the quantitative determination of trace amounts of vanadium in water is based on the catalytic effect of vanadium on the rate of oxidation of gallic acid by persulfate in acid solution. Under given conditions of concentrations of reactants, temperature, and reaction time, the extent of oxidation of gallic acid is proportional to the concentration of vanadium present. Vanadium is determined by measuring the absorbance of the sample at 415 m?? and comparison with standard solutions treated in an identical manner. Concentrations in the range of from 0.1 to 8.0 ??g. per liter may be determined with a standard deviation of 0.2 or less. By reducing the reaction time, the method may be extended to cover the range from 1 to 100 ??g. with a standard deviation of 0.8 or less. Several substances interfere, including chloride above 100 p.p.m., and bromide and iodide in much lower concentrations. Interference from the halides is eliminated or minimized by the addition of mercuric nitrate solution. Most other substances do not interfere at the concentration levels at which they commonly occur in natural waters.

  17. Silencing the hsp25 Gene Eliminates Migration Capability of the Highly Metastatic Murine 4T1 Breast Adenocarcinoma Cell

    PubMed Central

    Bausero, Maria A.; Bharti, Ajit; Page, Diana T.; Perez, Kristen D.; Eng, Jason W.-L.; Ordonez, Susana L.; Jantschitsch, Christian; Kindas-Muegge, Ingela; Ciocca, Daniel; Asea, Alexzander

    2006-01-01

    The 25-kDa heat shock protein (Hsp25) is associated with various malignancies and is expressed at high levels in biopsies as well as circulating in the serum of breast cancer patients. In this study, we used RNA interference technology to silence the hsp25 gene in 4T1 breast adenocarcinoma cells, known as a poorly immunogenic, highly metastatic cell line. We demonstrate that transfection of 4T1 cells with short interference RNA-Hsp25 dramatically inhibits proliferation as compared with control transfected cells. In addition, we show that 4T1 cells transfected with short interference RNA-Hsp25 abrogates tumor migration potential by a mechanism that is in part due to the repression of matrix metalloproteinase 9 expression and a concomitant upregulation of its antagonist, tissue inhibitor metalloproteinase 1. Taken together, these findings provide a model system for the study of metastatic potential of tumors and are suggestive of an earlier unrecognized role for Hsp25 in tumor migration. PMID:16340246

  18. Silencing the hsp25 gene eliminates migration capability of the highly metastatic murine 4T1 breast adenocarcinoma cell.

    PubMed

    Bausero, Maria A; Bharti, Ajit; Page, Diana T; Perez, Kristen D; Eng, Jason W-L; Ordonez, Susana L; Asea, Edwina E; Jantschitsch, Christian; Kindas-Muegge, Ingela; Ciocca, Daniel; Asea, Alexzander

    2006-01-01

    The 25-kDa heat shock protein (Hsp25) is associated with various malignancies and is expressed at high levels in biopsies as well as circulating in the serum of breast cancer patients. In this study, we used RNA interference technology to silence the hsp25 gene in 4T1 breast adenocarcinoma cells, known as a poorly immunogenic, highly metastatic cell line. We demonstrate that transfection of 4T1 cells with short interference RNA-Hsp25 dramatically inhibits proliferation as compared with control transfected cells. In addition, we show that 4T1 cells transfected with short interference RNA-Hsp25 abrogates tumor migration potential by a mechanism that is in part due to the repression of matrix metalloproteinase 9 expression and a concomitant upregulation of its antagonist, tissue inhibitor metalloproteinase 1. Taken together, these findings provide a model system for the study of metastatic potential of tumors and are suggestive of an earlier unrecognized role for Hsp25 in tumor migration. Copyright 2006 S. Karger AG, Basel.

  19. Effect of temporal and spectral noise features on gap detection behavior by calling green treefrogs.

    PubMed

    Höbel, Gerlinde

    2014-10-01

    Communication plays a central role in the behavioral ecology of many animals, yet the background noise generated by large breeding aggregations may impair effective communication. A common behavioral strategy to ameliorate noise interference is gap detection, where signalers display primarily during lulls in the background noise. When attempting gap detection, signalers have to deal with the fact that the spacing and duration of silent gaps is often unpredictable, and that noise varies in its spectral composition and may thus vary in the degree in which it impacts communication. I conducted playback experiments to examine how male treefrogs deal with the problem that refraining from calling while waiting for a gap to appear limits a male's ability to attract females, yet producing calls during noise also interferes with effective sexual communication. I found that the temporal structure of noise (i.e., duration of noise and silent gap segments) had a stronger effect on male calling behavior than the spectral composition. Males placed calls predominantly during silent gaps and avoided call production during short, but not long, noise segments. This suggests that male treefrogs use a calling strategy that maximizes the production of calls without interference, yet allows for calling to persist if lulls in the background noise are infrequent. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. Interference in the gg→h→γγ On-Shell Rate and the Higgs Boson Total Width.

    PubMed

    Campbell, John; Carena, Marcela; Harnik, Roni; Liu, Zhen

    2017-11-03

    We consider interference between the Higgs signal and QCD background in gg→h→γγ and its effect on the on-shell Higgs rate. The existence of sizable strong phases leads to destructive interference of about 2% of the on-shell cross section in the standard model. This effect can be enhanced by beyond the standard model physics. In particular, since it scales differently from the usual rates, the presence of interference allows indirect limits to be placed on the Higgs width in a novel way, using on-shell rate measurements. Our study motivates further QCD calculations to reduce uncertainties. We discuss possible width-sensitive observables, both using total and differential rates and find that the HL-LHC can potentially indirectly constrain widths of order tens of MeV.

  1. Sinning against nature: the theory of background conditions

    PubMed Central

    Blackford, R

    2006-01-01

    Debates about the moral and political acceptability of particular sexual practices and new technologies often include appeals to a supposed imperative to follow nature. If nature is understood as the totality of all phenomena or as those things that are not artificial, there is little prospect of developing a successful argument to impugn interference with it or sinning against it. At the same time, there are serious difficulties with approaches that seek to identify "proper" human functioning. An alternative approach is to understand interference with nature as acting in a manner that threatens basic background conditions to human choice. Arguably, the theory of background conditions helps explain much of the hostility to practices and technologies that allegedly sin against nature. The theory does not, however, entail that appeals to nature are relevant or rational. Such appeals should be subjected to sceptical scrutiny. Indeed, the theory suggests that arguments against practices and technologies that can be seen as contrary to nature sometimes exercise a psychological attraction that is disproportional to their actual cogency. PMID:17074819

  2. In vivo chemical and structural analysis of plant cuticular waxes using stimulated Raman scattering microscopy.

    PubMed

    Littlejohn, George R; Mansfield, Jessica C; Parker, David; Lind, Rob; Perfect, Sarah; Seymour, Mark; Smirnoff, Nicholas; Love, John; Moger, Julian

    2015-05-01

    The cuticle is a ubiquitous, predominantly waxy layer on the aerial parts of higher plants that fulfils a number of essential physiological roles, including regulating evapotranspiration, light reflection, and heat tolerance, control of development, and providing an essential barrier between the organism and environmental agents such as chemicals or some pathogens. The structure and composition of the cuticle are closely associated but are typically investigated separately using a combination of structural imaging and biochemical analysis of extracted waxes. Recently, techniques that combine stain-free imaging and biochemical analysis, including Fourier transform infrared spectroscopy microscopy and coherent anti-Stokes Raman spectroscopy microscopy, have been used to investigate the cuticle, but the detection sensitivity is severely limited by the background signals from plant pigments. We present a new method for label-free, in vivo structural and biochemical analysis of plant cuticles based on stimulated Raman scattering (SRS) microscopy. As a proof of principle, we used SRS microscopy to analyze the cuticles from a variety of plants at different times in development. We demonstrate that the SRS virtually eliminates the background interference compared with coherent anti-Stokes Raman spectroscopy imaging and results in label-free, chemically specific confocal images of cuticle architecture with simultaneous characterization of cuticle composition. This innovative use of the SRS spectroscopy may find applications in agrochemical research and development or in studies of wax deposition during leaf development and, as such, represents an important step in the study of higher plant cuticles. © 2015 American Society of Plant Biologists. All Rights Reserved.

  3. Effects of interior aircraft noise on speech intelligibility and annoyance

    NASA Technical Reports Server (NTRS)

    Pearsons, K. S.; Bennett, R. L.

    1977-01-01

    Recordings of the aircraft ambiance from ten different types of aircraft were used in conjunction with four distinct speech interference tests as stimuli to determine the effects of interior aircraft background levels and speech intelligibility on perceived annoyance in 36 subjects. Both speech intelligibility and background level significantly affected judged annoyance. However, the interaction between the two variables showed that above an 85 db background level the speech intelligibility results had a minimal effect on annoyance ratings. Below this level, people rated the background as less annoying if there was adequate speech intelligibility.

  4. Declarations of War and Authorizations for the Use of Military Force: Historical Background and Legal Implications

    DTIC Science & Technology

    2007-03-08

    recalled to active duty and the prohibition on recalling certain categories of retired officers to active duty “ in time of war or of national...suit would tend to endanger the security of naval operations in the war, or would tend to interfere with those operations, all further proceedings in ...reserves in any manner that would interfere with their use “ in time of war or national emergency, by other

  5. Cellular chromosome DNA interferes with fluorescence quantitative real-time PCR detection of HBV DNA in culture medium.

    PubMed

    Pan, Xiao-Ben; Wei, Lai; Han, Jin-Chao; Gao, Yan

    2008-01-01

    Fluorescence quantitative real-time PCR (FQ-PCR) is a recently developed technique increasingly used for clinical diagnosis by detection of hepatitis B virus (HBV) DNA in serum. FQ-PCR is also used in scientific research for detection of HBV DNA in cell culture. Understanding potential FQ-PCR interference factors can improve the accuracy of HBV DNA quantification in cell culture medium. HBV positive serum was diluted with culture medium to produce three test groups with HBV DNA levels of 5 x 10(7) copies/ml (high), 5 x 10(5) copies/ml (medium), and 5 x 10(3) copies/ml (low). Chromosome DNA was extracted from HepG2 cells and then added to high, medium, and low group samples at final concentrations of 0, 12.5, 25, 50, and 100 microg/ml. The samples were quantified by FQ-PCR and data were evaluated using statistical software. No marked changes were seen in the quantitative curves for high level HBV DNA samples when the samples were supplemented with 0-100 microg/ml of chromosome DNA. Interference was observed in medium level samples when 50 and 100 microg/ml of chromosome DNA was added. Interference was also observed in low level HBV DNA samples when the concentration of added chromosome DNA was greater than 25 microg/ml. The interference was eliminated when samples were digested by DNase I prior to PCR detection. In Conclusions, the presence of cellular chromosome DNA can interfere with the detection of HBV DNA by FQ-PCR. Removal of cellular chromosome DNA from culture media prior to FQ-PCR is necessary for reliable HBV DNA quantitative detection. (c) 2007 Wiley-Liss, Inc.

  6. Determination of intracellular nitrate.

    PubMed Central

    Romero, J M; Lara, C; Guerrero, M G

    1989-01-01

    A sensitive procedure has been developed for the determination of intracellular nitrate. The method includes: (i) preparation of cell lysates in 2 M-H3PO4 after separation of cells from the outer medium by rapid centrifugation through a layer of silicone oil, and (ii) subsequent nitrate analysis by ion-exchange h.p.l.c. with, as mobile phase, a solution containing 50 mM-H3PO4 and 2% (v/v) tetrahydrofuran, adjusted to pH 1.9 with NaOH. The determination of nitrate is subjected to interference by chloride and sulphate when present in the samples at high concentrations. Nitrite also interferes, but it is easily eliminated by treatment of the samples with sulphamic acid. The method has been successfully applied to the study of nitrate transport in the unicellular cyanobacterium Anacystis nidulans. PMID:2497740

  7. Potentiometric determination of saccharin in dietary products using mercurous nitrate as titrant.

    PubMed

    Fo, O F; Moraes, A J; Dos Santos, G

    1993-05-01

    A rapid, precise and low cost method for saccharin determination in dietary products is proposed. Saccharin in several samples is potentiometrically titrated with mercurous nitrate solution using a silver wire coated with a metallic mercury film as the working electrode, and the end point was found using a Gran's plot. The detection limit of sodium saccharin was 0.5 mg/ml and the best pH range was from 2.0 to 3.5. Sucrose, glucose, aspartame, sodium cyclamate, sorbitol, fructose, benzoic acid, salicylic acid and lactose do not interfere even in significant amounts. The interference due to the presence of chloride and/or phosphate ions can be eliminated by previous solvent extraction of this sweetener. Recovery of saccharin from various dietary products gave from 95.2 to 103.2% of the label claim.

  8. Spectrophotometric determination of titanium with tannin and thioglycollic acid and its application to titanium-treated steels and ferrous and non-ferrous alloys.

    PubMed

    Banerjee, S

    1986-04-01

    A sensitive spectrophotometric method for the determination of titanium by formation of its complex with tannin and thioglycollic acid at pH 4 has been developed. The intense yellow colour is measured at 400 nm and the system obeys Beer's law over the range 0.2-5 ppm titanium in the solution measured. The method is applicable to titanium-treated steels, stainless steels, permanent magnet alloys and duralumin alloys. The interference of Co, Ni, Cr, Mn, V, Mo and W can be eliminated by prior separation of titanium by controlled addition of cupferron in the presence of thioglycollic acid (TGA). Copper can be quantitatively separated by precipitation with TGA and determined complexometrically with EDTA, with PAN as indicator. Niobium interferes even in traces.

  9. [A cloud detection algorithm for MODIS images combining Kmeans clustering and multi-spectral threshold method].

    PubMed

    Wang, Wei; Song, Wei-Guo; Liu, Shi-Xing; Zhang, Yong-Ming; Zheng, Hong-Yang; Tian, Wei

    2011-04-01

    An improved method for detecting cloud combining Kmeans clustering and the multi-spectral threshold approach is described. On the basis of landmark spectrum analysis, MODIS data is categorized into two major types initially by Kmeans method. The first class includes clouds, smoke and snow, and the second class includes vegetation, water and land. Then a multi-spectral threshold detection is applied to eliminate interference such as smoke and snow for the first class. The method is tested with MODIS data at different time under different underlying surface conditions. By visual method to test the performance of the algorithm, it was found that the algorithm can effectively detect smaller area of cloud pixels and exclude the interference of underlying surface, which provides a good foundation for the next fire detection approach.

  10. Analysis of interference performance of tactical radio network

    NASA Astrophysics Data System (ADS)

    Nie, Hao; Cai, Xiaoxia; Chen, Hong

    2017-08-01

    Mobile Ad hoc network has a strong military background for its development as the core technology of the backbone network of US tactical Internet. And which tactical radio network, is the war in today's tactical use of the Internet more mature form of networking, mainly used in brigade and brigade following forces. This paper analyzes the typical protocol AODV in the tactical radio network, and then carries on the networking. By adding the interference device to the whole network, the battlefield environment is simulated, and then the throughput, delay and packet loss rate are analyzed, and the performance of the whole network and the single node before and after the interference is obtained.

  11. Determination of small amounts of molybdenum in tungsten and molybdenum ores

    USGS Publications Warehouse

    Grimaldi, F.S.; Wells, R.C.

    1943-01-01

    A rapid method has been developed for the determination of small amounts of molybdenum in tungsten and molybdenum ores. After removing iron and other major constituents the molybdenum thiocyanate color is developed in water-acetone solutions, using ammonium citrate to eliminate the interference of tungsten. Comparison is made by titrating a blank with a standard molybdenum solution. Aliquots are adjusted to deal with amounts of molybdenum ranging from 0.01 to 1.30 mg.

  12. Development of a sensitive monitor for hydrazine

    NASA Technical Reports Server (NTRS)

    Eiceman, Gary A.; Limero, Thomas; James, John T.

    1991-01-01

    The development of hand-held, ambient-temperature instruments that utilize ion mobility spectrometry (IMS) in the detection of hydrazine and monomethylhydrazine is reviewed. A development effort to eliminate ammonia interference through altering the ionization chemistry, based on adding 5-nonanone as dopant in the ionization region of the IMS, is presented. Calibration of this instrument conducted before and after STS-37 revealed no more than a 5 percent difference between calibration curves, without any appreciable loss of equipment function.

  13. Tunable geometric Fano resonances in a metal/insulator stack

    NASA Astrophysics Data System (ADS)

    Grotewohl, Herbert

    We present a theoretical analysis of surface-plasmon-mediated mode-coupling in a planar thin film metal/insulator stack. The spatial overlap of a surface plasmon polariton (SPP) and a waveguide mode results in a Fano interference analog. Tuning of the material parameters effects the modes and output fields of the system. Lastly, the intensity and phase sensitivity of the system are compared to a standard surface plasmon resonance (SPR). We begin with background information on Fano interference, an interference effect between two indistinguishable pathways. Originally described for autoionization, we discuss the analogs in other systems. We discuss the features of Fano interference in the mode diagrams, and the Fano resonance observed in the output field. The idea of a geometric Fano resonance (GFR) occurring in the angular domain is presented. Background information on surface plasmon polaritons is covered next. The dielectric properties of metals and how they relate to surface plasmons is first reviewed. The theoretical background of SPPs on an infinite planar surface is covered. The modes of a two planar interface metal/insulator stack are reviewed and the leaky properties of the waveguide are shown in the reflectance. We solve for modes of a three interface metal/insulator stack and shows an avoided crossing in the modes indicative of Fano interference. We observe the asymmetric Fano resonance in the angular domain in the reflectance. The tunability of the material parameters tunes the GFR of the system. The GFR tuning is explored and different Fano lineshapes are observed. We also observe a reversal of the asymmetry Fano lineshape, attributed to the relate phase interactions of the non-interacting modes. The phase of the GFR is calculated and discussed for the variations of the parameters. The reflected field is explored as the insulator permittivities are varied. As the waveguide permittivity is varied, we show there is little response from the system. As the exterior permittivity is varied, the reflectance exhibits the geometric Fano resonance and the tunability of the lineshape is explored. Finally, we calculate the sensitivities of our metal/insulator stack to changes in the permittivity and compare them to the sensitivities of SPRs.

  14. Interference in the g g → h → γ γ On-Shell Rate and the Higgs Boson Total Width

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Campbell, John; Carena, Marcela; Harnik, Roni

    We consider interference between the Higgs signal and QCD background inmore » $$gg\\rightarrow h \\rightarrow \\gamma\\gamma$$ and its effect on the on-shell Higgs rate. The existence of sizable strong phases leads to destructive interference of about 2% of the on-shell cross section in the Standard Model. This effect can be enhanced by beyond the standard model physics. In particular, since it scales differently from the usual rates, the presence of interference allows indirect limits to be placed on the Higgs width in a novel way, using on-shell rate measurements. Our study motivates further QCD calculations to reduce uncertainties. We discuss potential width-sensitive observables, both using total and differential rates and find that the HL-LHC can potentially indirectly probe widths of order tens of MeV.« less

  15. Contextual interference processing during fast categorisations of facial expressions.

    PubMed

    Frühholz, Sascha; Trautmann-Lengsfeld, Sina A; Herrmann, Manfred

    2011-09-01

    We examined interference effects of emotionally associated background colours during fast valence categorisations of negative, neutral and positive expressions. According to implicitly learned colour-emotion associations, facial expressions were presented with colours that either matched the valence of these expressions or not. Experiment 1 included infrequent non-matching trials and Experiment 2 a balanced ratio of matching and non-matching trials. Besides general modulatory effects of contextual features on the processing of facial expressions, we found differential effects depending on the valance of target facial expressions. Whereas performance accuracy was mainly affected for neutral expressions, performance speed was specifically modulated by emotional expressions indicating some susceptibility of emotional expressions to contextual features. Experiment 3 used two further colour-emotion combinations, but revealed only marginal interference effects most likely due to missing colour-emotion associations. The results are discussed with respect to inherent processing demands of emotional and neutral expressions and their susceptibility to contextual interference.

  16. Semiclassical description of photoionization microscopy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bordas, Ch.; Lepine, F.; Nicole, C.

    2003-07-01

    Recently, experiments have been reported where a geometrical interference pattern was observed when photoelectrons ejected in the threshold photoionization of xenon were detected in a velocity-map imaging apparatus [C. Nicole et al., Phys. Rev. Lett. 88, 133001 (2002)]. This technique, called photoionization microscopy, relies on the existence of interferences between various trajectories by which the electron moves from the atom to the plane of observation. Unlike previous predictions relevant to the hydrogenic case, the structure of the interference pattern evolves smoothly with the excess energy above the saddle point and is only weakly affected by the presence of continuum Starkmore » resonances. In this paper, we describe a semiclassical analysis of this process and present numerical simulations in excellent agreement with the experimental results. It is shown that the background contribution dominates in the observations, as opposed to the behavior expected for hydrogenic systems where the interference pattern is qualitatively different on quasidiscrete Stark resonances.« less

  17. Research on cloud background infrared radiation simulation based on fractal and statistical data

    NASA Astrophysics Data System (ADS)

    Liu, Xingrun; Xu, Qingshan; Li, Xia; Wu, Kaifeng; Dong, Yanbing

    2018-02-01

    Cloud is an important natural phenomenon, and its radiation causes serious interference to infrared detector. Based on fractal and statistical data, a method is proposed to realize cloud background simulation, and cloud infrared radiation data field is assigned using satellite radiation data of cloud. A cloud infrared radiation simulation model is established using matlab, and it can generate cloud background infrared images for different cloud types (low cloud, middle cloud, and high cloud) in different months, bands and sensor zenith angles.

  18. Extracorporeal virus elimination for the treatment of severe Ebola virus disease--first experience with lectin affinity plasmapheresis.

    PubMed

    Büttner, Stefan; Koch, Benjamin; Dolnik, Olga; Eickmann, Markus; Freiwald, Tilo; Rudolf, Sarah; Engel, Jürgen; Becker, Stephan; Ronco, Claudio; Geiger, Helmut

    2014-01-01

    Therapeutic options for Ebola virus disease (EVD) are currently limited to (1) best supportive care, and (2) evolving virus-specific therapies, resulting from decades of analyzing one of the world's deadliest diseases. Supportive care ranges from oral or intravenous rehydration therapy and anti-emetics in developing countries to much more extensive life-support interventions in resource-rich countries. Current EVD-specific therapies attempt to either interfere with the earliest steps of viral replication or to elicit a strong immune response against the virus. An entirely new approach is the extracorporeal elimination of viruses and viral glycoproteins by lectin affinity plasmapheresis. Herein, we report for the first time the successful and safe use of lectin affinity plasmapheresis in a patient with severe Ebola virus disease. © 2015 S. Karger AG, Basel.

  19. Differential phase-shift keying and channel equalization in free space optical communication system

    NASA Astrophysics Data System (ADS)

    Zhang, Dai; Hao, Shiqi; Zhao, Qingsong; Wan, Xiongfeng; Xu, Chenlu

    2018-01-01

    We present the performance benefits of differential phase-shift keying (DPSK) modulation in eliminating influence from atmospheric turbulence, especially for coherent free space optical (FSO) communication with a high communication rate. Analytic expression of detected signal is derived, based on which, homodyne detection efficiency is calculated to indicate the performance of wavefront compensation. Considered laser pulses always suffer from atmospheric scattering effect by clouds, intersymbol interference (ISI) in high-speed FSO communication link is analyzed. Correspondingly, the channel equalization method of a binormalized modified constant modulus algorithm based on set-membership filtering (SM-BNMCMA) is proposed to solve the ISI problem. Finally, through the comparison with existing channel equalization methods, its performance benefits of both ISI elimination and convergence speed are verified. The research findings have theoretical significance in a high-speed FSO communication system.

  20. Multi-path interferometric Josephson directional amplifier for qubit readout

    NASA Astrophysics Data System (ADS)

    Abdo, Baleegh; Bronn, Nicholas T.; Jinka, Oblesh; Olivadese, Salvatore; Brink, Markus; Chow, Jerry M.

    2018-04-01

    We realize and characterize a quantum-limited, directional Josephson amplifier suitable for qubit readout. The device consists of two nondegenerate, three-wave-mixing amplifiers that are coupled together in an interferometric scheme, embedded in a printed circuit board. Nonreciprocity is generated by applying a phase gradient between the same-frequency pumps feeding the device, which plays the role of the magnetic field in a Faraday medium. Directional amplification and reflection-gain elimination are induced via wave interference between multiple paths in the system. We measure and discuss the main figures of merit of the device and show that the experimental results are in good agreement with theory. An improved version of this directional amplifier is expected to eliminate the need for bulky, off-chip isolation stages that generally separate quantum systems and preamplifiers in high-fidelity, quantum-nondemolition measurement setups.

  1. The economic benefits of malaria elimination: do they include increases in tourism?

    PubMed Central

    2012-01-01

    Background Policy makers have speculated that one of the economic benefits of malaria elimination includes increases in foreign direct investment, particularly tourism. Methods This study examines the empirical relationship between the demand for travel and malaria cases in two countries with large tourism industries around the time in which they carried out malaria-elimination campaigns. In Mauritius, this analysis examines historical, yearly tourist arrivals and malaria cases from 1978–1999, accounting for the background secular trend of increasing international travel. In Dominican Republic, a country embarking upon malaria elimination, it employs a time-series analysis of the monthly, international tourist arrivals from 1998–2010 to determine whether the timing of significant deviations in tourist arrivals coincides with malaria outbreaks. Results While naïve relationships exist in both cases, the results show that the relationships between tourist arrivals and malaria cases are relatively weak and statistically insignificant once secular confounders are accounted for. Conclusions This suggests that any economic benefits from tourism that may be derived from actively pursuing elimination in countries that have high tourism potential are likely to be small when measured at a national level. Rather, tourism benefits are likely to be experienced with greater impact in more concentrated tourist areas within countries, and future studies should seek to assess these relationships at a regional or local level. PMID:22839351

  2. The Effect of Aging on the Dynamics of Reactive and Proactive Cognitive Control of Response Interference

    PubMed Central

    Xiang, Ling; Zhang, Baoqiang; Wang, Baoxi; Jiang, Jun; Zhang, Fenghua; Hu, Zhujing

    2016-01-01

    A prime-target interference task was used to investigate the effects of cognitive aging on reactive and proactive control after eliminating frequency confounds and feature repetitions from the cognitive control measures. We used distributional analyses to explore the dynamics of the two control functions by distinguishing the strength of incorrect response capture and the efficiency of suppression control. For reactive control, within-trial conflict control and between-trial conflict adaption were analyzed. The statistical analysis showed that there were no reliable between-trial conflict adaption effects for either young or older adults. For within-trial conflict control, the results revealed that older adults showed larger interference effects on mean RT and mean accuracy. Distributional analyses showed that the decline mainly stemmed from inefficient suppression rather than from stronger incorrect responses. For proactive control, older adults showed comparable proactive conflict resolution to young adults on mean RT and mean accuracy. Distributional analyses showed that older adults were as effective as younger adults in adjusting their responses based on congruency proportion information to minimize automatic response capture and actively suppress the direct response activation. The results suggest that older adults were less proficient at suppressing interference after conflict was detected but can anticipate and prevent inference in response to congruency proportion manipulation. These results challenge earlier views that older adults have selective deficits in proactive control but intact reactive control. PMID:27847482

  3. The Effect of Aging on the Dynamics of Reactive and Proactive Cognitive Control of Response Interference.

    PubMed

    Xiang, Ling; Zhang, Baoqiang; Wang, Baoxi; Jiang, Jun; Zhang, Fenghua; Hu, Zhujing

    2016-01-01

    A prime-target interference task was used to investigate the effects of cognitive aging on reactive and proactive control after eliminating frequency confounds and feature repetitions from the cognitive control measures. We used distributional analyses to explore the dynamics of the two control functions by distinguishing the strength of incorrect response capture and the efficiency of suppression control. For reactive control, within-trial conflict control and between-trial conflict adaption were analyzed. The statistical analysis showed that there were no reliable between-trial conflict adaption effects for either young or older adults. For within-trial conflict control, the results revealed that older adults showed larger interference effects on mean RT and mean accuracy. Distributional analyses showed that the decline mainly stemmed from inefficient suppression rather than from stronger incorrect responses. For proactive control, older adults showed comparable proactive conflict resolution to young adults on mean RT and mean accuracy. Distributional analyses showed that older adults were as effective as younger adults in adjusting their responses based on congruency proportion information to minimize automatic response capture and actively suppress the direct response activation. The results suggest that older adults were less proficient at suppressing interference after conflict was detected but can anticipate and prevent inference in response to congruency proportion manipulation. These results challenge earlier views that older adults have selective deficits in proactive control but intact reactive control.

  4. Spectral Interferences Manganese (Mn) - Europium (Eu) Lines in X-Ray Fluorescence Spectrometry Spectrum

    NASA Astrophysics Data System (ADS)

    Tanc, Beril; Kaya, Mustafa; Gumus, Lokman; Kumral, Mustafa

    2016-04-01

    X-ray fluorescence (XRF) spectrometry is widely used for quantitative and semi quantitative analysis of many major, minor and trace elements in geological samples. Some advantages of the XRF method are; non-destructive sample preparation, applicability for powder, solid, paste and liquid samples and simple spectrum that are independent from chemical state. On the other hand, there are some disadvantages of the XRF methods such as poor sensitivity for low atomic number elements, matrix effect (physical matrix effects, such as fine versus course grain materials, may impact XRF performance) and interference effect (the spectral lines of elements may overlap distorting results for one or more elements). Especially, spectral interferences are very significant factors for accurate results. In this study, semi-quantitative analyzed manganese (II) oxide (MnO, 99.99%) was examined. Samples were pelleted and analyzed with XRF spectrometry (Bruker S8 Tiger). Unexpected peaks were obtained at the side of the major Mn peaks. Although sample does not contain Eu element, in results 0,3% Eu2O3 was observed. These result can occur high concentration of MnO and proximity of Mn and Eu lines. It can be eliminated by using correction equation or Mn concentration can confirm with other methods (such as Atomic absorption spectroscopy). Keywords: Spectral Interferences; Manganese (Mn); Europium (Eu); X-Ray Fluorescence Spectrometry Spectrum.

  5. An Improved Fungal Mounting Technique for Nomarski Microscopy.

    ERIC Educational Resources Information Center

    Fairclough, Andrew; And Others

    1985-01-01

    Conventional sellotape techniques for fungal mounting produce interference patterns when using Normarsky microscopy. A technique is described which overcomes this problem and produces a permanent mount with a completely clear background. (Author/JN)

  6. Toward high value sensing: monolayer-protected metal nanoparticles in multivariable gas and vapor sensors.

    PubMed

    Potyrailo, Radislav A

    2017-08-29

    For detection of gases and vapors in complex backgrounds, "classic" analytical instruments are an unavoidable alternative to existing sensors. Recently a new generation of sensors, known as multivariable sensors, emerged with a fundamentally different perspective for sensing to eliminate limitations of existing sensors. In multivariable sensors, a sensing material is designed to have diverse responses to different gases and vapors and is coupled to a multivariable transducer that provides independent outputs to recognize these diverse responses. Data analytics tools provide rejection of interferences and multi-analyte quantitation. This review critically analyses advances of multivariable sensors based on ligand-functionalized metal nanoparticles also known as monolayer-protected nanoparticles (MPNs). These MPN sensing materials distinctively stand out from other sensing materials for multivariable sensors due to their diversity of gas- and vapor-response mechanisms as provided by organic and biological ligands, applicability of these sensing materials for broad classes of gas-phase compounds such as condensable vapors and non-condensable gases, and for several principles of signal transduction in multivariable sensors that result in non-resonant and resonant electrical sensors as well as material- and structure-based photonic sensors. Such features should allow MPN multivariable sensors to be an attractive high value addition to existing analytical instrumentation.

  7. Ratiometric Phosphorescent Probe for Thallium in Serum, Water, and Soil Samples Based on Long-Lived, Spectrally Resolved, Mn-Doped ZnSe Quantum Dots and Carbon Dots.

    PubMed

    Lu, Xiaomei; Zhang, Jinyi; Xie, Ya-Ni; Zhang, Xinfeng; Jiang, Xiaoming; Hou, Xiandeng; Wu, Peng

    2018-02-20

    Thallium (Tl) is an extremely toxic heavy metal and exists in very low concentrations in the environment, but its sensing is largely underexplored as compared to its neighboring elements in the periodic table (especially mercury and lead). In this work, we developed a ratiometric phosphorescent nanoprobe for thallium detection based on Mn-doped ZnSe quantum dots (QDs) and water-soluble carbon dots (C-dots). Upon excitation with 360 nm, Mn-doped ZnSe QDs and C-dots can emit long-lived and spectrally resolved phosphorescence at 580 and 440 nm, respectively. In the presence of thallium, the phosphorescence emission from Mn-doped ZnSe QDs could be selectively quenched, while that from C-dots retained unchanged. Therefore, a ratiometric phosphorescent probe was thus developed, which can eliminate the potential influence from both background fluorescence and other analyte-independent external environment factors. Several other heavy metal ions caused interferences to thallium detection but could be efficiently masked with EDTA. The proposed method offered a detection limit of 1 μg/L, which is among the most sensitive probes ever reported. Successful application of this method for thallium detection in biological serum as well as in environmental water and soil samples was demonstrated.

  8. Challenges and opportunities for heavy scalar searches in the tt¯ channel at the LHC

    DOE PAGES

    Carena, Marcela; Liu, Zhen

    2016-11-25

    Heavy scalar and pseudoscalar resonance searches through themore » $$gg\\rightarrow S\\rightarrow t\\bar t$$ process are challenging due to the peculiar behavior of the large interference effects with the standard model $$t\\bar t$$ background. Such effects generate non-trivial lineshapes from additional relative phases between the signal and background amplitudes. We provide the analytic expressions for the differential cross sections to understand the interference effects in the heavy scalar signal lineshapes. We extend our study to the case of CP-violation and further consider the effect of bottom quarks in the production and decay processes. We also evaluate the contributions from additional particles to the gluon fusion production process, such as stops and vector-like quarks, that could lead to significant changes in the behavior of the signal lineshapes. Taking into account the large interference effects, we perform lineshape searches at the LHC and discuss the importance of the systematic uncertainties and smearing effects. Lastly, we present projected sensitivities for two LHC performance scenarios to probe the $$gg\\rightarrow S \\rightarrow t\\bar t$$ channel in various models.« less

  9. Accelerator mass spectrometry of Strontium-90 for homeland security, environmental monitoring, and human health

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tumey, S J; Brown, T A; Hamilton, T F

    2008-03-03

    Strontium-90 is one of the most hazardous materials managed by agencies charged with protecting the public from radiation. Traditional radiometric methods have been limited by low sample throughput and slow turnaround times. Mass spectrometry offers the advantage of shorter analysis times and the ability to measure samples immediately after processing, however conventional mass spectrometric techniques are susceptible to molecular isobaric interferences that limit their overall sensitivity. In contrast, accelerator mass spectrometry is insensitive to molecular interferences and we have therefore begun developing a method for determination of {sup 90}Sr by accelerator mass spectrometry. Despite a pervasive interference from {sup 90}Zr,more » our initial development has yielded an instrumental background of {approx} 10{sup 8} atoms (75 mBq) per sample. Further refinement of our system (e.g., redesign of our detector, use of alternative target materials) is expected to push the background below 10{sup 6} atoms, close to the theoretical limit for AMS. Once we have refined our system and developed suitable sample preparation protocols, we will utilize our capability in applications to homeland security, environmental monitoring, and human health.« less

  10. A novel Kalman filter based video image processing scheme for two-photon fluorescence microscopy

    NASA Astrophysics Data System (ADS)

    Sun, Wenqing; Huang, Xia; Li, Chunqiang; Xiao, Chuan; Qian, Wei

    2016-03-01

    Two-photon fluorescence microscopy (TPFM) is a perfect optical imaging equipment to monitor the interaction between fast moving viruses and hosts. However, due to strong unavoidable background noises from the culture, videos obtained by this technique are too noisy to elaborate this fast infection process without video image processing. In this study, we developed a novel scheme to eliminate background noises, recover background bacteria images and improve video qualities. In our scheme, we modified and implemented the following methods for both host and virus videos: correlation method, round identification method, tree-structured nonlinear filters, Kalman filters, and cell tracking method. After these procedures, most of noises were eliminated and host images were recovered with their moving directions and speed highlighted in the videos. From the analysis of the processed videos, 93% bacteria and 98% viruses were correctly detected in each frame on average.

  11. Moderated histogram equalization, an automatic means of enhancing the contrast in digital light micrographs reversibly.

    PubMed

    Entwistle, A

    2004-06-01

    A means for improving the contrast in the images produced from digital light micrographs is described that requires no intervention by the experimenter: zero-order, scaling, tonally independent, moderated histogram equalization. It is based upon histogram equalization, which often results in digital light micrographs that contain regions that appear to be saturated, negatively biased or very grainy. Here a non-decreasing monotonic function is introduced into the process, which moderates the changes in contrast that are generated. This method is highly effective for all three of the main types of contrast found in digital light micrography: bright objects viewed against a dark background, e.g. fluorescence and dark-ground or dark-field image data sets; bright and dark objects sets against a grey background, e.g. image data sets collected with phase or Nomarski differential interference contrast optics; and darker objects set against a light background, e.g. views of absorbing specimens. Moreover, it is demonstrated that there is a single fixed moderating function, whose actions are independent of the number of elements of image data, which works well with all types of digital light micrographs, including multimodal or multidimensional image data sets. The use of this fixed function is very robust as the appearance of the final image is not altered discernibly when it is applied repeatedly to an image data set. Consequently, moderated histogram equalization can be applied to digital light micrographs as a push-button solution, thereby eliminating biases that those undertaking the processing might have introduced during manual processing. Finally, moderated histogram equalization yields a mapping function and so, through the use of look-up tables, indexes or palettes, the information present in the original data file can be preserved while an image with the improved contrast is displayed on the monitor screen.

  12. A Background of a Volatile Plant Compound Alters Neural and Behavioral Responses to the Sex Pheromone Blend in a Moth.

    PubMed

    Dupuy, Fabienne; Rouyar, Angéla; Deisig, Nina; Bourgeois, Thomas; Limousin, Denis; Wycke, Marie-Anne; Anton, Sylvia; Renou, Michel

    2017-01-01

    Recognition of intra-specific olfactory signals within a complex environment of plant-related volatiles is crucial for reproduction in male moths. Sex pheromone information is detected by specific olfactory receptor neurons (Phe-ORNs), highly abundant on the male antenna. The information is then transmitted to the pheromone processing macroglomerular complex (MGC) within the primary olfactory center, the antennal lobe, where it is processed by local interneurons and projection neurons. Ultimately a behavioral response, orientation toward the pheromone source, is elicited. Volatile plant compounds (VPCs) are detected by other functional types of olfactory receptor neurons (ORNs) projecting in another area of the antennal lobe. However, Phe-ORNs also respond to some VPCs. Female-produced sex pheromones are emitted within a rich environment of VPCs, some of which have been shown to interfere with the detection and processing of sex pheromone information. As interference between the different odor sources might depend on the spatial and temporal features of the two types of stimuli, we investigated here behavioral and neuronal responses to a brief sex pheromone blend pulse in a VPC background as compared to a control background in the male noctuid moth Agrotis ipsilon . We observed male orientation behavior in a wind tunnel and recorded responses of Phe-ORNs and MGC neurons to a brief sex pheromone pulse within a background of individual VPCs. We also recorded the global input signal to the MGC using in vivo calcium imaging with the same stimulation protocol. We found that VPCs eliciting a response in Phe-ORNs and MGC neurons masked responses to the pheromone and decreased the contrast between background odor and the sex pheromone at both levels, whereas α-pinene did not interfere with first order processing. The calcium signal produced in response to a VPC background was tonic, lasting longer than the VPC stimulus duration, and masked entirely the pheromone response. One percent heptanal and linalool, in addition to the masking effect, caused a clear delay in responses of MGC neurons to the sex pheromone. Upwind flight toward the pheromone in a wind tunnel was also delayed but otherwise not altered by different doses of heptanal.

  13. How to maintain chain drives

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wright, J.L.

    1992-06-18

    Properly selected and maintained chain drives can be expected to give thousands of hours of reliable service. Selection is usually done just once. This paper reports on good maintenance which must be done regularly to keep the drive operating. An effective maintenance program for roller chain should include correct type and adequate amounts of lubrication, replacement of worn chains and sprockets, and elimination of drive interferences. It is important to set u a lubrication and inspection/correction schedule to ensure that all required maintenance is carried out.

  14. Biological water quality monitoring using chemiluminescent and bioluminescent techniques

    NASA Technical Reports Server (NTRS)

    Thomas, R. R.

    1978-01-01

    Automated chemiluminescence and bioluminescence sensors were developed for the continuous monitoring of microbial levels in water supplies. The optimal chemical procedures were determined for the chemiluminescence system to achieve maximum sensitivity. By using hydrogen peroxide, reaction rate differentiation, ethylene diamine tetraacetic acid (EDTA), and carbon monoxide pretreatments, factors which cause interference were eliminated and specificity of the reaction for living and dead bacteria was greatly increased. By employing existing technology with some modifications, a sensitive and specific bioluminescent system was developed.

  15. Highly-reliable fly-by-light/power-by-wire technology

    NASA Technical Reports Server (NTRS)

    Pitts, Felix L.

    1993-01-01

    This paper presents in viewgraph format an overview of the program at NASA Langley Research Center to develop fly-by-light/power-by-wire (FBL/PBW) technology. Benefits of FBL/PBW include intrinsic electromagnetic interference (EMI) immunity and lifetime immunity to signal EMI of optics; simplified certification; the elimination of hydraulics, engine bleed air, and variable speed, constant frequency drive; and weight and volume reduction. The paper summarizes a study on the electromagnetic environmental effects on FBL/PBW systems. The paper concludes with FY 1993 plans.

  16. A joint precoding scheme for indoor downlink multi-user MIMO VLC systems

    NASA Astrophysics Data System (ADS)

    Zhao, Qiong; Fan, Yangyu; Kang, Bochao

    2017-11-01

    In this study, we aim to improve the system performance and reduce the implementation complexity of precoding scheme for visible light communication (VLC) systems. By incorporating the power-method algorithm and the block diagonalization (BD) algorithm, we propose a joint precoding scheme for indoor downlink multi-user multi-input-multi-output (MU-MIMO) VLC systems. In this scheme, we apply the BD algorithm to eliminate the co-channel interference (CCI) among users firstly. Secondly, the power-method algorithm is used to search the precoding weight for each user based on the optimal criterion of signal to interference plus noise ratio (SINR) maximization. Finally, the optical power restrictions of VLC systems are taken into account to constrain the precoding weight matrix. Comprehensive computer simulations in two scenarios indicate that the proposed scheme always has better bit error rate (BER) performance and lower computation complexity than that of the traditional scheme.

  17. Separation and preconcentration of the rare-earth elements and yttrium from geological materials by ion-exchange and sequential acid elution

    USGS Publications Warehouse

    Crock, J.G.; Lichte, F.E.; Riddle, G.O.; Beech, C.L.

    1986-01-01

    The abundance of rare-earth elements (REE) and yttrium in geological materials is generally low, and most samples contain elements that interfere in the determination of the REE and Y, so a separation and/or preconcentration step is often necessary. This is often achieved by ion-exchange chromatography with either nitric or hydrochloric acid. It is advantageous, however, to use both acids sequentially. The final solution thus obtained contains only the REE and Y, with minor amounts of Al, Ba, Ca, Sc, Sr and Ti. Elements that potentially interfere, such as Be, Co, Cr, Fe, Mn, Th, U, V and Zr, are virtually eliminated. Inductively-coupled argon plasma atomic-emission spectroscopy can then be used for a final precise and accurate measurement. The method can also be used with other instrumental methods of analysis. ?? 1986.

  18. Low-cost, high-fidelity, adaptive cancellation of periodic 60 Hz noise.

    PubMed

    Wesson, Kyle D; Ochshorn, Robert M; Land, Bruce R

    2009-12-15

    A common method to eliminate unwanted power line interference in neurobiology laboratories where sensitive electronic signals are measured is with a notch filter. However a fixed-frequency notch filter cannot remove all power line noise contamination since inherent frequency and phase variations exist in the contaminating signal. One way to overcome the limitations of a fixed-frequency notch filter is with adaptive noise cancellation. Adaptive noise cancellation is an active approach that uses feedback to create a signal that when summed with the contaminated signal destructively interferes with the noise component leaving only the desired signal. We have implemented an optimized least mean square adaptive noise cancellation algorithm on a low-cost 16 MHz, 8-bit microcontroller to adaptively cancel periodic 60 Hz noise. In our implementation, we achieve between 20 and 25 dB of cancellation of the fundamental 60 Hz noise component.

  19. Method and system to synchronize acoustic therapy with ultrasound imaging

    NASA Technical Reports Server (NTRS)

    Hossack, James (Inventor); Owen, Neil (Inventor); Bailey, Michael R. (Inventor)

    2009-01-01

    Interference in ultrasound imaging when used in connection with high intensity focused ultrasound (HIFU) is avoided by employing a synchronization signal to control the HIFU signal. Unless the timing of the HIFU transducer is controlled, its output will substantially overwhelm the signal produced by ultrasound imaging system and obscure the image it produces. The synchronization signal employed to control the HIFU transducer is obtained without requiring modification of the ultrasound imaging system. Signals corresponding to scattered ultrasound imaging waves are collected using either the HIFU transducer or a dedicated receiver. A synchronization processor manipulates the scattered ultrasound imaging signals to achieve the synchronization signal, which is then used to control the HIFU bursts so as to substantially reduce or eliminate HIFU interference in the ultrasound image. The synchronization processor can alternatively be implemented using a computing device or an application-specific circuit.

  20. Electromagnetic interference modeling and suppression techniques in variable-frequency drive systems

    NASA Astrophysics Data System (ADS)

    Yang, Le; Wang, Shuo; Feng, Jianghua

    2017-11-01

    Electromagnetic interference (EMI) causes electromechanical damage to the motors and degrades the reliability of variable-frequency drive (VFD) systems. Unlike fundamental frequency components in motor drive systems, high-frequency EMI noise, coupled with the parasitic parameters of the trough system, are difficult to analyze and reduce. In this article, EMI modeling techniques for different function units in a VFD system, including induction motors, motor bearings, and rectifierinverters, are reviewed and evaluated in terms of applied frequency range, model parameterization, and model accuracy. The EMI models for the motors are categorized based on modeling techniques and model topologies. Motor bearing and shaft models are also reviewed, and techniques that are used to eliminate bearing current are evaluated. Modeling techniques for conventional rectifierinverter systems are also summarized. EMI noise suppression techniques, including passive filter, Wheatstone bridge balance, active filter, and optimized modulation, are reviewed and compared based on the VFD system models.

  1. An interference-based optical authentication scheme using two phase-only masks with different diffraction distances

    NASA Astrophysics Data System (ADS)

    Lu, Dajiang; He, Wenqi; Liao, Meihua; Peng, Xiang

    2017-02-01

    A new method to eliminate the security risk of the well-known interference-based optical cryptosystem is proposed. In this method, which is suitable for security authentication application, two phase-only masks are separately placed at different distances from the output plane, where a certification image (public image) can be obtained. To further increase the security and flexibility of this authentication system, we employ one more validation image (secret image), which can be observed at another output plane, for confirming the identity of the user. Only if the two correct masks are properly settled at their positions one could obtain two significant images. Besides, even if the legal users exchange their masks (keys), the authentication process will fail and the authentication results will not reveal any information. Numerical simulations are performed to demonstrate the validity and security of the proposed method.

  2. High-order corrections on the laser cooling limit in the Lamb-Dicke regime.

    PubMed

    Yi, Zhen; Gu, Wen-Ju

    2017-01-23

    We investigate corrections on the cooling limit of high-order Lamb-Dicke (LD) parameters in the double electromagnetically induced transparency (EIT) cooling scheme. Via utilizing quantum interferences, the single-phonon heating mechanism vanishes and the system evolves to a double dark state, from which we will obtain the mechanical occupation on the single-phonon excitation state. In addition, the further correction induced by two-phonon heating transitions is included to achieve a more accurate cooling limit. There exist two pathways of two-phonon heating transitions: direct two-phonon excitation from the dark state and further excitation from the single-phonon excited state. By adding up these two parts of correction, the obtained analytical predictions show a well consistence with numerical results. Moreover, we find that the two pathways can destructively interfere with each other, leading to the elimination of two-phonon heating transitions and achieving a lower cooling limit.

  3. Fiber optic TV direct

    NASA Technical Reports Server (NTRS)

    Kassak, John E.

    1991-01-01

    The objective of the operational television (OTV) technology was to develop a multiple camera system (up to 256 cameras) for NASA Kennedy installations where camera video, synchronization, control, and status data are transmitted bidirectionally via a single fiber cable at distances in excess of five miles. It is shown that the benefits (such as improved video performance, immunity from electromagnetic interference and radio frequency interference, elimination of repeater stations, and more system configuration flexibility) can be realized if application of the proven fiber optic transmission concept is used. The control system will marry the lens, pan and tilt, and camera control functions into a modular based Local Area Network (LAN) control network. Such a system does not exist commercially at present since the Television Broadcast Industry's current practice is to divorce the positional controls from the camera control system. The application software developed for this system will have direct applicability to similar systems in industry using LAN based control systems.

  4. The effects on cruise drag of installing long-duct refan-engine nacelles on the McDonnell Douglas DC-8-50 and -61

    NASA Technical Reports Server (NTRS)

    Callaghan, J. T.; Donelson, J. E.; Morelli, J. P.

    1973-01-01

    A high-speed wind tunnel test was conducted to determine the effect on cruise performance of installing long-duct refan-engine nacelles on the DC-8-50 and -61 models. Drag data and wing/pylon/nacelle channel pressure data are presented. At a typical cruise condition there exists a very small interference drag penalty of less than one-percent of total cruise data for the Refan installation. Pressure data indicate that some supersonic flow is present in the inboard channel of the inboard refan nacelle installation, but it is not sufficient to cause any wave drag on boundary layer separation. One pylon modification, which takes the form of pylon bumps, was tested. It resulted in a drag penalty, because its design goal of eliminating shock-related interference drag was not required and the bump thus became a source of additional parasite drag.

  5. Signal to background interference in p p →t H-→t W-b b ¯ at the LHC Run II

    NASA Astrophysics Data System (ADS)

    Arhrib, Abdesslam; Benbrik, Rachid; Moretti, Stefano; Santos, Rui; Sharma, Pankaj

    2018-04-01

    We investigate in the Large Hadron Collider (LHC) environment the possibility that sizeable interference effects between a heavy charged Higgs boson signal produced via b g →t H- (+c .c . ) scattering and decaying via H-→W-A →W-b b ¯ (+c .c . ) and the irreducible background given by b g →t W-b b ¯ topologies could spoil current search approaches where the former and latter channels are treated separately. The rationale for this comes from the fact that a heavy charged Higgs state can have a large width, which can also happen for the C P -odd neutral Higgs state emerging in the ensuing decays, which in turn enables such interferences. We conclude that effects are very significant, both at the inclusive and exclusive level (i.e., both before and after H± selection cuts are enforced, respectively) and typically of a destructive nature. This, therefore, implies that currently established LHC reaches for heavy charged Higgs bosons require some level of rescaling. However, this is possible a posteriori, as the aforementioned H± selection cuts shape the interference contributions at the differential level in a way similar to that of the isolated H± signal, so there is no need to reassess the efficiency of the individual cuts. We show such effects quantitatively by borrowing benchmark points from different Yukawa types of a 2-Higgs doublet model parameter space for H± values starting from around 200 GeV.

  6. Elimination of N,O-bis(trimethylsilyl)trifluoroacetamide interference by base treatment in derivatization gas chromatography mass spectrometry determination of parts per billion of alcohols in a food additive.

    PubMed

    Zhu, Koudi; Gu, Binghe; Kerry, Michael; Mintert, Markus; Luong, Jim; Pursch, Matthias

    2017-03-24

    A novel base treatment followed by liquid-liquid extraction was developed to remove the interference of excess derivatization reagent BSTFA [N,O-Bis(trimethylsilyl)trifluoroacetamide] and its byproducts for trace determination of 1-chloro-2-propanol and 2-chloro-1-propanol in a food additive. The corresponding trimethylsilyl derivatives were analyzed by gas chromatography mass spectrometry (GC/MS) detection in selective ion monitoring mode. Due to a large volume splitless injection needed for achieving the required sensitivity, excess BSTFA in the derivatization sample solution interfered with the trimethylsilyl derivatives of the analytes of interest, making their quantitation not attainable. Efforts were made to decompose BSTFA while keeping the trimethylsilyl derivatives intact. Water or aqueous sulfuric acid treatment converted BSTFA into mainly N-trimethylsilyltrifluoroacetamide, which partitions between aqueous and organic layers. In contrast, aqueous sodium hydroxide decomposed BSTFA into trifluoroacetic acid, which went entirely into the aqueous layer. No BSTFA or its byproduct N-trimethylsilyltrifluoroacetamide or trifluroacetamide was found in the organic layer where the derivatized alcohols existed, which in turn completely eliminated their interference, enabling accurate and precise determination of parts per billion of the short-chain alcohols in the food additive. Contrary to the conventional wisdom that a trimethylsilyl derivative is susceptible to hydrolysis, the derivatized short-chain alcohols were found stable even in the presence of 0.17N aqueous sodium hydroxide as the improved GC/MS method was validated successfully, with a satisfactory linearity response in the concentration range of 10-400ng/g (regression coefficient greater than 0.999), good method precision (<4%), good recovery (90-98%), and excellent limit of detection (3ng/g) and limit of quantitation (10ng/g). Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Centralized Routing and Scheduling Using Multi-Channel System Single Transceiver in 802.16d

    NASA Astrophysics Data System (ADS)

    Al-Hemyari, A.; Noordin, N. K.; Ng, Chee Kyun; Ismail, A.; Khatun, S.

    This paper proposes a cross-layer optimized strategy that reduces the effect of interferences from neighboring nodes within a mesh networks. This cross-layer design relies on the routing information in network layer and the scheduling table in medium access control (MAC) layer. A proposed routing algorithm in network layer is exploited to find the best route for all subscriber stations (SS). Also, a proposed centralized scheduling algorithm in MAC layer is exploited to assign a time slot for each possible node transmission. The cross-layer optimized strategy is using multi-channel single transceiver and single channel single transceiver systems for WiMAX mesh networks (WMNs). Each node in WMN has a transceiver that can be tuned to any available channel for eliminating the secondary interference. Among the considered parameters in the performance analysis are interference from the neighboring nodes, hop count to the base station (BS), number of children per node, slot reuse, load balancing, quality of services (QoS), and node identifier (ID). Results show that the proposed algorithms significantly improve the system performance in terms of length of scheduling, channel utilization ratio (CUR), system throughput, and average end to end transmission delay.

  8. Eye tracking reveals the cost of switching between self and other perspectives in a visual perspective-taking task.

    PubMed

    Ferguson, Heather J; Apperly, Ian; Cane, James E

    2017-08-01

    Previous studies have shown that while people can rapidly and accurately compute their own and other people's visual perspectives, they experience difficulty ignoring the irrelevant perspective when the two perspectives differ. We used the "avatar" perspective-taking task to examine the mechanisms that underlie these egocentric (i.e., interference from their own perspective) and altercentric (i.e., interference from the other person's perspective) tendencies. Participants were eye-tracked as they verified the number of discs in a visual scene according to either their own or an on-screen avatar's perspective. Crucially in some trials the two perspectives were inconsistent (i.e., each saw a different number of discs), while in others they were consistent. To examine the effect of perspective switching, performance was compared for trials that were preceded with the same versus a different perspective cue. We found that altercentric interference can be reduced or eliminated when participants stick with their own perspective across consecutive trials. Our eye-tracking analyses revealed distinct fixation patterns for self and other perspective taking, suggesting that consistency effects in this paradigm are driven by implicit mentalizing of what others can see, and not automatic directional cues from the avatar.

  9. [Application of single-band brightness variance ratio to the interference dissociation of cloud for satellite data].

    PubMed

    Qu, Wei-ping; Liu, Wen-qing; Liu, Jian-guo; Lu, Yi-huai; Zhu, Jun; Qin, Min; Liu, Cheng

    2006-11-01

    In satellite remote-sensing detection, cloud as an interference plays a negative role in data retrieval. How to discern the cloud fields with high fidelity thus comes as a need to the following research. A new method rooting in atmospheric radiation characteristics of cloud layer, in the present paper, presents a sort of solution where single-band brightness variance ratio is used to detect the relative intensity of cloud clutter so as to delineate cloud field rapidly and exactly, and the formulae of brightness variance ratio of satellite image, image reflectance variance ratio, and brightness temperature variance ratio of thermal infrared image are also given to enable cloud elimination to produce data free from cloud interference. According to the variance of the penetrating capability for different spectra bands, an objective evaluation is done on cloud penetration of them with the factors that influence penetration effect. Finally, a multi-band data fusion task is completed using the image data of infrared penetration from cirrus nothus. Image data reconstruction is of good quality and exactitude to show the real data of visible band covered by cloud fields. Statistics indicates the consistency of waveband relativity with image data after the data fusion.

  10. A supercritical airfoil experiment

    NASA Technical Reports Server (NTRS)

    Mateer, G. G.; Seegmiller, H. L.; Hand, L. A.; Szodruck, J.

    1994-01-01

    The purpose of this investigation is to provide a comprehensive data base for the validation of numerical simulations. The objective of the present paper is to provide a tabulation of the experimental data. The data were obtained in the two-dimensional, transonic flowfield surrounding a supercritical airfoil. A variety of flows were studied in which the boundary layer at the trailing edge of the model was either attached or separated. Unsteady flows were avoided by controlling the Mach number and angle of attack. Surface pressures were measured on both the model and wind tunnel walls, and the flowfield surrounding the model was documented using a laser Doppler velocimeter (LDV). Although wall interference could not be completely eliminated, its effect was minimized by employing the following techniques. Sidewall boundary layers were reduced by aspiration, and upper and lower walls were contoured to accommodate the flow around the model and the boundary-layer growth on the tunnel walls. A data base with minimal interference from a tunnel with solid walls provides an ideal basis for evaluating the development of codes for the transonic speed range because the codes can include the wall boundary conditions more precisely than interference connections can be made to the data sets.

  11. Polymeric mercaptosilane-modified platinum electrodes for elimination of interferants in glucose biosensors.

    PubMed

    Jung, S K; Wilson, G S

    1996-02-15

    An oxidase-based glucose sensor has been developed that uses a mercaptosilane-modified platinum electrode to achieve selectivity of electrochemical interferants. A platinum-iridium (9:1) wire (0.178 mm o.d., sensing area of 1.12 mm2) is modified with (3-mercaptopropyl)trimethoxysilane. The modified sensors show excellent operational stability for more than 5 days. Glucose oxidase is immobilized on the modified surface (i) by using 3-maleimidopropionic acid as a linker or (ii) by cross-liking with bovine serum albumin using glutaraldehyde. Sensitivities in the range of 9.97 nA/mM glucose are observed when the enzyme is immobilized by method ii. Lower sensitivities (1.13 x 10(-1) nA/mM glucose) are observed when immobilization method i is employed. In terms of linear response range, the sensor enzyme-immobilized by method i is superior to that immobilized by method ii. The linearity is improved upon coating the enzyme layer with polyurethane. The sensor immobilized by method ii and coated with polyurethane exhibits a linear range to 15 mM glucose and excellent selectivity to glucose (0.47 nA/mM) against interferants such as ascorbic acid, uric acid, and acetaminophen.

  12. Research Review: The Role of Diet in the Treatment of Attention-Deficit/Hyperactivity Disorder--An Appraisal of the Evidence on Efficacy and Recommendations on the Design of Future Studies

    ERIC Educational Resources Information Center

    Stevenson, Jim; Buitelaar, Jan; Cortese, Samuele; Ferrin, Maite; Konofal, Eric; Lecendreux, Michel; Simonoff, Emily; Wong, Ian C. K.; Sonuga-Barke, Edmund

    2014-01-01

    Background: The efficacy of three dietary treatments for ADHD has been repeatedly tested in randomized controlled trials (RCTs). These interventions are restricted elimination diets (RED), artificial food colour elimination (AFCE) and supplementation with free fatty acids (SFFA). There have been three systematic reviews and associated…

  13. Suppression of AC railway power-line interference in ECG signals recorded by public access defibrillators

    PubMed Central

    Dotsinsky, Ivan

    2005-01-01

    Background Public access defibrillators (PADs) are now available for more efficient and rapid treatment of out-of-hospital sudden cardiac arrest. PADs are used normally by untrained people on the streets and in sports centers, airports, and other public areas. Therefore, automated detection of ventricular fibrillation, or its exclusion, is of high importance. A special case exists at railway stations, where electric power-line frequency interference is significant. Many countries, especially in Europe, use 16.7 Hz AC power, which introduces high level frequency-varying interference that may compromise fibrillation detection. Method Moving signal averaging is often used for 50/60 Hz interference suppression if its effect on the ECG spectrum has little importance (no morphological analysis is performed). This approach may be also applied to the railway situation, if the interference frequency is continuously detected so as to synchronize the analog-to-digital conversion (ADC) for introducing variable inter-sample intervals. A better solution consists of rated ADC, software frequency measuring, internal irregular re-sampling according to the interference frequency, and a moving average over a constant sample number, followed by regular back re-sampling. Results The proposed method leads to a total railway interference cancellation, together with suppression of inherent noise, while the peak amplitudes of some sharp complexes are reduced. This reduction has negligible effect on accurate fibrillation detection. Conclusion The method is developed in the MATLAB environment and represents a useful tool for real time railway interference suppression. PMID:16309558

  14. Corner detection and sorting method based on improved Harris algorithm in camera calibration

    NASA Astrophysics Data System (ADS)

    Xiao, Ying; Wang, Yonghong; Dan, Xizuo; Huang, Anqi; Hu, Yue; Yang, Lianxiang

    2016-11-01

    In traditional Harris corner detection algorithm, the appropriate threshold which is used to eliminate false corners is selected manually. In order to detect corners automatically, an improved algorithm which combines Harris and circular boundary theory of corners is proposed in this paper. After detecting accurate corner coordinates by using Harris algorithm and Forstner algorithm, false corners within chessboard pattern of the calibration plate can be eliminated automatically by using circular boundary theory. Moreover, a corner sorting method based on an improved calibration plate is proposed to eliminate false background corners and sort remaining corners in order. Experiment results show that the proposed algorithms can eliminate all false corners and sort remaining corners correctly and automatically.

  15. Ambient Background Particulate Compositiion Outdoor Natural Background: Interferents/Clutter

    DTIC Science & Technology

    2011-08-01

    FIGURES 1. Map of UK Sampling Locations, Lizard, Pershore, Birmingham, Lichfield 10 2. Mean UK Airborne Pollen , Fungi, and Bacteria and/or their Sum...routinely other than for health effects. Allergy caused by pollen (>15 urn) and mold is monitored for health effects by National Allergy 9...occurrence. To achieve this, measurement of pollens , bacteria, and fungal spores and dust particulates were undertaken for weekly periods at four

  16. Direct Detection of Nucleic Acid with Minimizing Background and Improving Sensitivity Based on a Conformation-Discriminating Indicator.

    PubMed

    Zhu, Lixuan; Qing, Zhihe; Hou, Lina; Yang, Sheng; Zou, Zhen; Cao, Zhong; Yang, Ronghua

    2017-08-25

    As is well-known, the nucleic acid indicator-based strategy is one of the major approaches to monitor the nucleic acid hybridization-mediated recognition events in biochemical analysis, displaying obvious advantages including simplicity, low cost, convenience, and generality. However, conventional indicators either hold strong self-fluorescence or can be lighted by both ssDNA and dsDNA, lacking absolute selectivity for a certain conformation, always with high background interference and low sensitivity in sensing; and additional processing (e.g., nanomaterial-mediated background suppression, and enzyme-catalyzed signal amplification) is generally required to improve the detection performance. In this work, a carbazole derivative, EBCB, has been synthesized and screened as a dsDNA-specific fluorescent indicator. Compared with conventional indicators under the same conditions, EBCB displayed a much higher selective coefficient for dsDNA, with little self-fluorescence and negligible effect from ssDNA. Based on its superior capability in DNA conformation-discrimination, high sensitivity with minimizing background interference was demonstrated for direct detection of nucleic acid, and monitoring nucleic acid-based circuitry with good reversibity, resulting in low detection limit and high capability for discriminating base-mismatching. Thus, we expect that this highly specific DNA conformation-discriminating indicator will hold good potential for application in biochemical sensing and molecular logic switching.

  17. Selection of fluorescence lidar operating parameters for SNR maximization

    NASA Technical Reports Server (NTRS)

    Heaps, W. S.

    1981-01-01

    Fluorescence lidar when applicable offers one of the most sensitive methods for measuring the concentration of trace constituents of the atmosphere. In the conduct of a fluorescence lidar experiment, a number of parameters which can be used to optimize the SNR can be controlled. In this paper the optimum division of laser pulses centered on and off the fluorescence excitation wavelength is calculated as a function of the ratio of the fluorescence signal strength to the strength of fluorescence from interfering species. For strong interference signals the time should be divided equally on and off the line. For strong fluorescence signals the time on line is proportional to the square root of the on-line off-line signal ratio. The optimization of the integration time for varying values of signal-to-background and signal-to-interference ratios, atmospheric attenuation, laser energy variations, background measurement time, and on-line off-line time division is also considered.

  18. Pulsed Multiple Reaction Monitoring Approach to Enhancing Sensitivity of a Tandem Quadrupole Mass Spectrometer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Belov, Mikhail E.; Prasad, Satendra; Prior, David C.

    2011-02-23

    Liquid chromatography (LC)-triple quadrupole mass spectrometers operating in a Multiple Reaction Monitoring (MRM) mode are increasingly used for quantitative analysis of low abundance analytes in highly complex biochemical matrices. After development and selection of optimum MRM transition, sensitivity and data quality limitations are largely related to mass spectral peak interferences from sample or matrix constituents and statistical limitations at low number of ions reaching the detector. Herein, we report a new approach to enhancing MRM sensitivity by converting the continuous stream of ions from the ion source into a pulsed ion beam through the use of an Ion Funnel Trapmore » (IFT). Evaluation of the pulsed MRM approach was performed with a tryptic digest of Shewanella oneidensis strain MR-1 spiked with several reference peptides. The sensitivity improvement observed with the IFT coupled to the triple quadrupole instrument is based on several unique features. First, ion accumulation in the radio frequency (RF) ion trap facilitates improved droplet desolvation, which is manifested in the reduced background ion noise at the detector. Second, signal amplitude for a given transition is enhanced because of an order-of-magnitude increase in the ion charge density per unit time compared to a continuous mode of operation. Third, signal detection at the full duty cycle is obtained, as the trap use eliminates dead times between transitions, which are inevitable with continuous ion streams. In comparison with the conventional approach, the pulsed MRM signals showed up to 5-fold enhanced peak amplitude and 2-3 fold reduced chemical background, resulting in an improvement in the limit of detection (LOD) by a factor of ~ 4 to ~ 8.« less

  19. The Fallacy of the Longevity Elixir: Negligible Senescence May be Achieved, but Not by Using Something Physical.

    PubMed

    Kyriazis, Marios; Apostolides, Andreas

    2015-01-01

    The process of aging is a continuum of degeneration which eventually leads to loss of function and clinically manifest disease. Yet, in the purely therapeutic sense, there is a distinct clinical and practical separation between age-related degenerative diseases and the background process of aging itself. It is quite possible that biomedical technologies will prove invaluable in treating or alleviating the impact of distinct age-related degenerative diseases such as cardiovascular disease, arthritis or dementia. However, when it comes to addressing the fundamental, background stochastic nature of aging, it is unlikely that regenerative biotechnologies will have any appreciable impact in continually counteracting the process. In this paper we discuss some essential conceptual obstacles, both functional and translational, which will prove overwhelming and which preclude the notion that aging can be eliminated by using physical therapies. Our reasoning is two-fold: 1. Disruptive regenerative biotechnologies interfere with the complex, dynamic topological architecture of the human organism, in a manner that will render them unsuitable for clinical use against all age-related degeneration. 2. Even if some regenerative biotechnological treatments are developed in the laboratory, the translational issues will be insurmountable, and the treatments will thus be practically unusable by the general public at large. Predictions about the near or mid-term development of rejuvenating biotechnologies are not sufficiently grounded, and do not provide a framework for effective practical achievement of negligible senescence. Instead, the answer must lie in more global and abstract methods which align well with evolutionary mechanisms based on techno-cultural societal necessities. These are likely to operate in a way which ultimately may downgrade the importance of human aging and make it an evolutionarily unnecessary process.

  20. Interval Between Infections and Viral Hierarchy Are Determinants of Viral Interference Following Influenza Virus Infection in a Ferret Model

    PubMed Central

    Laurie, Karen L.; Guarnaccia, Teagan A.; Carolan, Louise A.; Yan, Ada W. C.; Aban, Malet; Petrie, Stephen; Cao, Pengxing; Heffernan, Jane M.; McVernon, Jodie; Mosse, Jennifer; Kelso, Anne; McCaw, James M.; Barr, Ian G.

    2015-01-01

    Background. Epidemiological studies suggest that, following infection with influenza virus, there is a short period during which a host experiences a lower susceptibility to infection with other influenza viruses. This viral interference appears to be independent of any antigenic similarities between the viruses. We used the ferret model of human influenza to systematically investigate viral interference. Methods. Ferrets were first infected then challenged 1–14 days later with pairs of influenza A(H1N1)pdm09, influenza A(H3N2), and influenza B viruses circulating in 2009 and 2010. Results. Viral interference was observed when the interval between initiation of primary infection and subsequent challenge was <1 week. This effect was virus specific and occurred between antigenically related and unrelated viruses. Coinfections occurred when 1 or 3 days separated infections. Ongoing shedding from the primary virus infection was associated with viral interference after the secondary challenge. Conclusions. The interval between infections and the sequential combination of viruses were important determinants of viral interference. The influenza viruses in this study appear to have an ordered hierarchy according to their ability to block or delay infection, which may contribute to the dominance of different viruses often seen in an influenza season. PMID:25943206

  1. The development of performance-monitoring function in the posterior medial frontal cortex

    PubMed Central

    Fitzgerald, Kate Dimond; Perkins, Suzanne C.; Angstadt, Mike; Johnson, Timothy; Stern, Emily R.; Welsh, Robert C.; Taylor, Stephan F.

    2009-01-01

    Background Despite its critical role in performance-monitoring, the development of posterior medial prefrontal cortex (pMFC) in goal-directed behaviors remains poorly understood. Performance monitoring depends on distinct, but related functions that may differentially activate the pMFC, such as monitoring response conflict and detecting errors. Developmental differences in conflict- and error-related activations, coupled with age-related changes in behavioral performance, may confound attempts to map the maturation of pMFC functions. To characterize the development of pMFC-based performance monitoring functions, we segregated interference and error-processing, while statistically controlling for performance. Methods Twenty-one adults and 23 youth performed an event-related version of the Multi-Source Interference Task during functional magnetic resonance imaging (fMRI). Linear modeling of interference and error contrast estimates derived from the pMFC were regressed on age, while covarying for performance. Results Interference- and error-processing were associated with robust activation of the pMFC in both youth and adults. Among youth, interference- and error-related activation of the pMFC increased with age, independent of performance. Greater accuracy associated with greater pMFC activity during error commission in both groups. Discussion Increasing pMFC response to interference and errors occurs with age, likely contributing to the improvement of performance monitoring capacity during development. PMID:19913101

  2. Olfaction in Parkin carriers in Chinese patients with Parkinson disease.

    PubMed

    Wang, Ying; Wu, Jian-Jun; Liu, Feng-Tao; Chen, Kui; Chen, Chen; Luo, Su-Shan; Wang, Yi-Xuan; Li, Da-Ke; Guan, Rong-Yuan; Yang, Yu-Jie; An, Yu; Wang, Jian; Sun, Yi-Min

    2017-05-01

    Olfactory identification was reported to be better among PD (Parkinson disease) patients with Parkin mutations, but previous studies didn't eliminate the interference of other PD related genes on olfaction, and whether olfaction of Parkin mutations patients was better in Chinese population was still unknown. To assess olfaction function among PD patients with Parkin mutations in Chinese population. A total of 226 PD patients with a positive family history or an early-onset age (<50 years) were enrolled for genetic testing of PD related genes by target sequencing and multiple ligation-dependent probe amplification. The clinical data including olfactory function test were investigated. Linear regression was performed to adjust for the covariates between all groups. There were 68 patients found having a negative result in PD genetic testing and 43 patients carrying homozygous or compound heterozygous Parkin mutations. Among them, 49 PD panel negative patients and 33 PD- Parkin patients had results of olfactory assessment. PD -Parkin patients performed significantly better on the Sniffin' Sticks tests than panel negative patients (8.0 ± 1.7 vs. 5.7 ± 1.9, p  <   .001), but still worse compared to healthy controls (9.4 ± 1.5, p  =   .003). These differences persisted after adjusting for confounders. Among Chinese population, PD -Parkin patients had relatively preserved olfaction compared to PD panel negative patients after eliminating the interference of other PD related genes, but were still worse than healthy controls.

  3. Detection of total and A1c-glycosylated hemoglobin in human whole blood using sandwich immunoassays on polydimethylsiloxane-based antibody microarrays.

    PubMed

    Chen, Huang-Han; Wu, Chih-Hsing; Tsai, Mei-Ling; Huang, Yi-Jing; Chen, Shu-Hui

    2012-10-16

    The percentage of glycosylated hemoglobin A1c (%GHbA1c) in human whole blood indicates the average plasma glucose concentration over a prolonged period of time and is used to diagnose diabetes. However, detecting GHbA1c in the whole blood using immunoassays has limited detection sensitivity due to its low percentage in total hemoglobin (tHb) and interference from various glycan moieties in the sample. We have developed a sandwich immunoassay using an antibody microarray on a polydimethylsiloxane (PDMS) substrate modified with fluorinated compounds to detect tHb and glycosylated hemoglobin A1c (GHbA1c) in human whole blood without sample pretreatment. A polyclonal antibody against hemoglobin (Hb) immobilized on PDMS is used as a common capture probe to enrich all forms of Hb followed by detection via monoclonal anti-Hb and specific monoclonal anti-GHbA1c antibodies for tHb and GHbA1c detection, respectively. This method prevents the use of glycan binding molecules and dramatically reduces the background interference, yielding a detection limit of 3.58 ng/mL for tHb and 0.20 ng/mL for GHbA1c. The fluorinated modification on PDMS is superior to the glass substrate and eliminates the need for the blocking step which is required in commercial enzyme linked immunosorbent assay (ELISA) kits. Moreover, the detection sensitivity for GHbA1c is 4-5 orders of magnitude higher, but the required sample amount is 25 times less than the commercial method. On the basis of patient sample data, a good linear correlation between %GHbA1c values determined by our method and the certified high performance liquid chromatography (HPLC) standard method is shown with R(2) > 0.98, indicating the great promise of the developed method for clinical applications.

  4. Planetary Surface Exploration Using Raman Spectroscopy on Rovers and Landers

    NASA Astrophysics Data System (ADS)

    Blacksberg, Jordana; Alerstam, E.; Maruyama, Y.; Charbon, E.; Rossman, G. R.

    2013-10-01

    Planetary surface exploration using laser induced breakdown spectroscopy (LIBS) to probe the composition of rocks has recently become a reality with the operation of the mast-mounted ChemCam instrument onboard the Curiosity rover. Following this success, Raman spectroscopy has steadily gained support as a means for using laser spectroscopy to identify not just composition but mineral phases, without the need for sample preparation. The RLS Raman Spectrometer is included on the payload for the ExoMars mission, and a Raman spectrometer has been included in an example strawman payload for NASA’s Mars 2020 mission. Raman spectroscopy has been identified by the community as a feasible means for pre-selection of samples on Mars for subsequent return to Earth. We present a next-generation instrument that builds on the widely used green-Raman technique to provide a means for performing Raman spectroscopy without the background noise that is often generated by fluorescence of minerals and organics. Microscopic Raman spectroscopy with a laser spot size smaller than the grains of interest can provide surface mapping of mineralogy while preserving morphology. A very small laser spot size 1 µm) is often necessary to identify minor phases that are often of greater interest than the matrix phases. In addition to the difficulties that can be posed by fine-grained material, fluorescence interference from the very same material is often problematic. This is particularly true for many of the minerals of interest that form in environments of aqueous alteration and can be highly fluorescent. We use time-resolved laser spectroscopy to eliminate fluorescence interference that can often make it difficult or impossible to obtain Raman spectra. We will discuss significant advances leading to the feasibility of a compact time-resolved spectrometer, including the development of a new solid-state detector capable of sub-ns time resolution. We will present results on planetary analog minerals to demonstrate the instrument performance including fluorescence rejection.

  5. Optimization of collision/reaction gases for determination of 90Sr in atmospheric particulate matter by inductively coupled plasma tandem mass spectrometry after direct introduction of air via a gas-exchange device

    NASA Astrophysics Data System (ADS)

    Suzuki, Yoshinari; Ohara, Ryota; Matsunaga, Kirara

    2017-09-01

    Nuclear power plant accidents release radioactive strontium 90 (90Sr) into the environment. Monitoring of 90Sr, although important, is difficult and time consuming because it emits only beta radiation. We have developed a new analytical system that enables real-time analysis of 90Sr in atmospheric particulate matter with an analytical run time of only 10 min. Briefly, after passage of an air sample through an impactor, a small fraction of the sample is introduced into a gas-exchange device, where the air is replaced by Ar. Then the sample is directly introduced into an inductively coupled plasma tandem mass spectrometry (ICP-MS/MS) system equipped with a collision/reaction cell to eliminate isobaric interferences on 90Sr from 90Zr+, 89Y1H+, and 90Y+. Experiments with various reaction gas conditions revealed that these interferences could be minimized under the following optimized conditions: 1.0 mL min- 1 O2, 10.0 mL min- 1 H2, and 1.0 mL min- 1 NH3. The estimated background equivalent concentration and estimated detection limit of the system were 9.7 × 10- 4 and 3.6 × 10- 4 ng m- 3, respectively, which are equivalent to 4.9 × 10- 6 and 1.8 × 10- 6 Bq cm- 3. Recoveries of Sr in PM2.5 measured by real-time analysis compared to those obtained by simultaneously collection on filter was 53 ± 23%, and using this recovery, the detection limit as PM2.5 was estimated to be 3.4 ± 1.5 × 10- 6 Bq cm- 3. That is, this system enabled detection of 90Sr at concentrations < 5 × 10- 6 Bq cm- 3 even considering the insufficient fusion/vaporization/ionization efficiency of Sr in PM2.5.

  6. Chemical-mechanical polishing of recessed microelectromechanical devices

    DOEpatents

    Barron, Carole C.; Hetherington, Dale L.; Montague, Stephen

    1999-01-01

    A method is disclosed for micromachining recessed layers (e.g. sacrificial layers) of a microelectromechanical system (MEMS) device formed in a cavity etched into a semiconductor substrate. The method uses chemical-mechanical polishing (CMP) with a resilient polishing pad to locally planarize one or more of the recessed layers within the substrate cavity. Such local planarization using the method of the present invention is advantageous for improving the patterning of subsequently deposited layers, for eliminating mechanical interferences between functional elements (e.g. linkages) of the MEMS device, and for eliminating the formation of stringers. After the local planarization of one or more of the recessed layers, another CMP step can be provided for globally planarizing the semiconductor substrate to form a recessed MEMS device which can be integrated with electronic circuitry (e.g. CMOS, BiCMOS or bipolar circuitry) formed on the surface of the substrate.

  7. Spectrophotometric analyses of hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) in water.

    PubMed

    Shi, Cong; Xu, Zhonghou; Smolinski, Benjamin L; Arienti, Per M; O'Connor, Gregory; Meng, Xiaoguang

    2015-07-01

    A simple and accurate spectrophotometric method for on-site analysis of royal demolition explosive (RDX) in water samples was developed based on the Berthelot reaction. The sensitivity and accuracy of an existing spectrophotometric method was improved by: replacing toxic chemicals with more stable and safer reagents; optimizing the reagent dose and reaction time; improving color stability; and eliminating the interference from inorganic nitrogen compounds in water samples. Cation and anion exchange resin cartridges were developed and used for sample pretreatment to eliminate the effect of ammonia and nitrate on RDX analyses. The detection limit of the method was determined to be 100 μg/L. The method was used successfully for analysis of RDX in untreated industrial wastewater samples. It can be used for on-site monitoring of RDX in wastewater for early detection of chemical spills and failure of wastewater treatment systems. Copyright © 2015. Published by Elsevier B.V.

  8. Chemical-mechanical polishing of recessed microelectromechanical devices

    DOEpatents

    Barron, C.C.; Hetherington, D.L.; Montague, S.

    1999-07-06

    A method is disclosed for micromachining recessed layers (e.g. sacrificial layers) of a microelectromechanical system (MEMS) device formed in a cavity etched into a semiconductor substrate. The method uses chemical-mechanical polishing (CMP) with a resilient polishing pad to locally planarize one or more of the recessed layers within the substrate cavity. Such local planarization using the method of the present invention is advantageous for improving the patterning of subsequently deposited layers, for eliminating mechanical interferences between functional elements (e.g. linkages) of the MEMS device, and for eliminating the formation of stringers. After the local planarization of one or more of the recessed layers, another CMP step can be provided for globally planarizing the semiconductor substrate to form a recessed MEMS device which can be integrated with electronic circuitry (e.g., CMOS, BiCMOS or bipolar circuitry) formed on the surface of the substrate. 23 figs.

  9. Elimination of the asymmetric modes in a Ka-band super overmoded coaxial Cerenkov oscillator

    NASA Astrophysics Data System (ADS)

    Bai, Zhen; Zhang, Jun; Zhong, Huihuang; Zhao, Xuelong; Yang, Fuxiang

    2017-12-01

    The issue of asymmetric modes output of a Ka-band super overmoded coaxial Cerenkov oscillator is analyzed in this paper. Due to serious passband overlapping in a super overmoded coaxial slow wave structure (SWS), the asymmetric competition mode EH11 can hardly be suppressed thoroughly by the methods adopted in moderately overmoded devices, especially in the startup of oscillation. If the output structures reflect the asymmetric modes, the asymmetric mode competition in SWS will be aggravated and the normal operation state will be destroyed. In order to solve this problem, a taper waveguide is inserted at a specific position to achieve the destructive interference of the reflected TM11, and a special support structure is designed to avoid reflection of TE11. With these methods, asymmetric mode competition can be successfully eliminated, and the oscillator is capable of achieving a steady fundamental mode operation performance.

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Campbell, John; Carena, Marcela; Harnik, Roni

    We consider interference between the Higgs signal and QCD background inmore » $$gg\\rightarrow h \\rightarrow \\gamma\\gamma$$ and its effect on the on-shell Higgs rate. The existence of sizable strong phases leads to destructive interference of about 2% of the on-shell cross section in the Standard Model. This effect can be enhanced by beyond the standard model physics. In particular, since it scales differently from the usual rates, the presence of interference allows indirect limits to be placed on the Higgs width in a novel way, using on-shell rate measurements. Our study motivates further QCD calculations to reduce uncertainties. We discuss potential width-sensitive observables, both using total and differential rates and find that the HL-LHC can potentially indirectly probe widths of order tens of MeV.« less

  11. Visual Working Memory Capacity and Proactive Interference

    PubMed Central

    Hartshorne, Joshua K.

    2008-01-01

    Background Visual working memory capacity is extremely limited and appears to be relatively immune to practice effects or the use of explicit strategies. The recent discovery that visual working memory tasks, like verbal working memory tasks, are subject to proactive interference, coupled with the fact that typical visual working memory tasks are particularly conducive to proactive interference, suggests that visual working memory capacity may be systematically under-estimated. Methodology/Principal Findings Working memory capacity was probed behaviorally in adult humans both in laboratory settings and via the Internet. Several experiments show that although the effect of proactive interference on visual working memory is significant and can last over several trials, it only changes the capacity estimate by about 15%. Conclusions/Significance This study further confirms the sharp limitations on visual working memory capacity, both in absolute terms and relative to verbal working memory. It is suggested that future research take these limitations into account in understanding differences across a variety of tasks between human adults, prelinguistic infants and nonlinguistic animals. PMID:18648493

  12. Clinical laboratory verification of thyroglobulin concentrations in the presence of autoantibodies to thyroglobulin: comparison of EIA, radioimmunoassay and LC MS/MS measurements in an Urban Hospital.

    PubMed

    Wheeler, Sarah E; Liu, Li; Blair, Harry C; Sivak, Richard; Longo, Nancy; Tischler, Jeffery; Mulvey, Kathryn; Palmer, Octavia M Peck

    2017-12-08

    Thyroglobulin (Tg) measurements assess recurrence in post-thyroidectomy thyroid cancer patients. Tg measurements by enzyme immunoassays (EIA) can be falsely elevated by interference from Tg autoantibodies (TgAb). Radioimmunoassay (RIA) is less susceptible to TgAb interference and has been the standard-of-care test for TgAb positive patients. Recently developed liquid chromatography tandem mass spectrometry (LC-MS/MS) methods may eliminate TgAb interference. We assessed the performance of Tg measurements by EIA, RIA and LC-MS/MS to evaluate TgAb interference differences. We measured TgAb and Tg in 50 plasma samples from 40 patients in whom Tg measurement was part of their routine follow-up and 10 healthy volunteers. Discrepancy between EIA and both LC-MS/MS and RIA was observed at low Tg concentrations (≤ 7.55 ng/mL) in TgAb positive specimens (LC-MS/MS = 1.9 * EIA - 0.03, r = 0.68). RIA and LC-MS/MS Tg measurements in TgAb positive specimens with low Tg concentrations had improved correlation but demonstrated bias (LC MS/MS = 0.6 * RIA - 1.4, r = 0.90). Disagreement between methods may be attributed to LC-MS/MS reported Tg concentrations as undetectable compared to RIA. It seems likely that most discrepant cases are falsely elevated in RIA due to TgAb interference, however, some cases appear below the detection limit of LC-MS/MS; implementation of LC-MS/MS by clinicians will require lower detection limits.

  13. Dual-wavelength recording, a simple algorithm to eliminate interferences due to UV-absorbing substances in capillary electrophoresis.

    PubMed

    Seaux, Liesbeth; Van Houcke, Sofie; Dumoulin, Els; Fiers, Tom; Lecocq, Elke; Delanghe, Joris R

    2014-08-01

    Analytical interferences have been described due to the presence of various exogenous UV-absorbing substances in serum. Iodine-based X-ray contrast agents and various antibiotics have been reported to interfere with interpretation of serum protein pherograms, resulting in false diagnosis of paraproteinemia. In the present study, we have explored the possibility of measuring UV absorbance at two distinct wavelengths (210 and 246 nm) to distinguish between true and false paraproteins on a Helena V8 clinical electrophoresis instrument. This study demonstrates that most substances potentially interfering with serum protein electrophoresis show UV-absorption spectra that are distinct from those of serum proteins. Scanning at 246 nm allows detection of all described interfering agents. Comparing pherograms recorded at both wavelengths (210 and 246 nm) enables to distinguish paraproteins from UV-absorbing substances. In case of a true paraprotein, the peak with an electrophoretic mobility in the gamma-region decreases, whereas the X-ray contrast media and antibiotics show an increased absorption when compared to the basic setting (210 nm). The finding of iodine-containing contrast media interfering with serum protein electrophoresis is not uncommon. In a clinical series, interference induced by contrast media was reported in 54 cases (of 13 237 analyses), corresponding with a prevalence of 0.4%. In the same series, 1631 true paraproteins (12.3%) were detected. Implementation of the proposed algorithm may significantly improve the interpretation of routine electrophoresis results. However, attention should still be paid to possible interference due to presence of atypical proteins fractions (e.g., tumor markers, C3). © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Adaptive suppression of power line interference in ultra-low field magnetic resonance imaging in an unshielded environment

    NASA Astrophysics Data System (ADS)

    Huang, Xiaolei; Dong, Hui; Qiu, Yang; Li, Bo; Tao, Quan; Zhang, Yi; Krause, Hans-Joachim; Offenhäusser, Andreas; Xie, Xiaoming

    2018-01-01

    Power-line harmonic interference and fixed-frequency noise peaks may cause stripe-artifacts in ultra-low field (ULF) magnetic resonance imaging (MRI) in an unshielded environment and in a conductively shielded room. In this paper we describe an adaptive suppression method to eliminate these artifacts in MRI images. This technique utilizes spatial correlation of the interference from different positions, and is realized by subtracting the outputs of the reference channel(s) from those of the signal channel(s) using wavelet analysis and the least squares method. The adaptive suppression method is first implemented to remove the image artifacts in simulation. We then experimentally demonstrate the feasibility of this technique by adding three orthogonal superconducting quantum interference device (SQUID) magnetometers as reference channels to compensate the output of one 2nd-order gradiometer. The experimental results show great improvement in the imaging quality in both 1D and 2D MRI images at two common imaging frequencies, 1.3 kHz and 4.8 kHz. At both frequencies, the effective compensation bandwidth is as high as 2 kHz. Furthermore, we examine the longitudinal relaxation times of the same sample before and after compensation, and show that the MRI properties of the sample did not change after applying adaptive suppression. This technique can effectively increase the imaging bandwidth and be applied to ULF MRI detected by either SQUIDs or Faraday coil in both an unshielded environment and a conductively shielded room.

  15. Immediate Judgments of Learning are Insensitive to Implicit Interference Effects at Retrieval

    PubMed Central

    Eakin, Deborah K.; Hertzog, Christopher

    2013-01-01

    We conducted three experiments to determine whether metamemory predictions at encoding, immediate judgments of learning (IJOLs) are sensitive to implicit interference effects that will occur at retrieval. Implicit interference was manipulated by varying the association set size of the cue (Exps. 1 & 2) or the target (Exp. 3). The typical finding is that memory is worse for large-set-size cues and targets, but only when the target is studied alone and later prompted with a related cue (extralist). When the pairs are studied together (intralist), recall is the same regardless of set size; set-size effects are eliminated. Metamemory predictions at retrieval, such as delayed JOLs (DJOLs) and feeling of knowing (FOK) judgments accurately reflect implicit interference effects (e.g., Eakin & Hertzog, 2006). In Experiment 1, we contrasted cue-set-size effects on IJOLs, DJOLs, and FOKs. After wrangling with an interesting methodological conundrum related to set size effects (Exp. 2), we found that whereas DJOLs and FOKs accurately predicted set size effects on retrieval, a comparison between IJOLs and no-cue IJOLs demonstrated that immediate judgments did not vary with set size. In Experiment 3, we confirmed this finding by manipulating target set size. Again, IJOLs did not vary with set size whereas DJOLs and FOKs did. The findings provide further evidence for the inferential view regarding the source of metamemory predictions, as well as indicate that inferences are based on different sources depending on when in the memory process predictions are made. PMID:21915761

  16. Heterophilic interference in specimens yielding false-reactive results on the Abbott 4th generation ARCHITECT HIV Ag/Ab Combo assay.

    PubMed

    Lavoie, S; Caswell, D; Gill, M J; Kadkhoda, K; Charlton, C L; Levett, P N; Hatchette, T; Garceau, R; Maregmen, J; Mazzulli, T; Needle, R; Kadivar, K; Kim, J

    2018-07-01

    False-reactivity in HIV-negative specimens has been detected in HIV fourth-generation antigen/antibody or 'combo' assays which are able to detect both anti-HIV-1/HIV-2 antibodies and HIV-1 antigen. We sought to characterize these specimens and determine the effect of heterophilic interference. Specimens previously testing as false-reactive on the Abbott ARCHITECT HIV Ag/Ab combo assay and re-tested on a different (Siemens ADVIA Centaur HIV Ag/Ab) assay. A subset of these specimens were also pre-treated with heterophilic blocking agents and re-tested on the Abbott assay. Here we report that 95% (252/264) of clinical specimens that were repeatedly reactive on the Abbott ARCHITECT HIV Ag/Ab combo assay (S/Co range, 0.94-678) were negative when re-tested on a different fourth generation HIV combo assay (Siemens ADVIA Centaur HIV Ag/Ab). All 264 samples were subsequently confirmed to be HIV negative. On a small subset (57) of specimens with available volume, pre-treatment with two different reagents (HBT; Heterophilic Blocking Tube, NABT; Non-Specific Blocking Tube) designed to block heterophilic antibody interference either eliminated (HBT) or reduced (NABT) the false reactivity when re-tested on the ARCHITECT HIV Ag/Ab combo assay. Our results suggest that the Abbott ARCHITECT HIV Ag/Ab combo assay can be prone to heterophilic antibody interference. Crown Copyright © 2018. Published by Elsevier B.V. All rights reserved.

  17. A masked least-squares smoothing procedure for artifact reduction in scanning-EMG recordings.

    PubMed

    Corera, Íñigo; Eciolaza, Adrián; Rubio, Oliver; Malanda, Armando; Rodríguez-Falces, Javier; Navallas, Javier

    2018-01-11

    Scanning-EMG is an electrophysiological technique in which the electrical activity of the motor unit is recorded at multiple points along a corridor crossing the motor unit territory. Correct analysis of the scanning-EMG signal requires prior elimination of interference from nearby motor units. Although the traditional processing based on the median filtering is effective in removing such interference, it distorts the physiological waveform of the scanning-EMG signal. In this study, we describe a new scanning-EMG signal processing algorithm that preserves the physiological signal waveform while effectively removing interference from other motor units. To obtain a cleaned-up version of the scanning signal, the masked least-squares smoothing (MLSS) algorithm recalculates and replaces each sample value of the signal using a least-squares smoothing in the spatial dimension, taking into account the information of only those samples that are not contaminated with activity of other motor units. The performance of the new algorithm with simulated scanning-EMG signals is studied and compared with the performance of the median algorithm and tested with real scanning signals. Results show that the MLSS algorithm distorts the waveform of the scanning-EMG signal much less than the median algorithm (approximately 3.5 dB gain), being at the same time very effective at removing interference components. Graphical Abstract The raw scanning-EMG signal (left figure) is processed by the MLSS algorithm in order to remove the artifact interference. Firstly, artifacts are detected from the raw signal, obtaining a validity mask (central figure) that determines the samples that have been contaminated by artifacts. Secondly, a least-squares smoothing procedure in the spatial dimension is applied to the raw signal using the not contaminated samples according to the validity mask. The resulting MLSS-processed scanning-EMG signal (right figure) is clean of artifact interference.

  18. New shielding configurations for a simultaneous PET/MRI scanner at 7T

    PubMed Central

    Peng, Bo J.; Wu, Yibao; Cherry, Simon R.; Walton, Jeffrey H.

    2014-01-01

    Understanding sources of electromagnetic interference are important in designing any electronic system. This is especially true when combining positron emission tomography (PET) and magnetic resonance imaging (MRI) in a multimodality system as coupling between the subsystems can degrade the performance of either modality. For this reason, eliminating radio frequency (RF) interference and gradient-induced eddy currents have been major challenges in building simultaneous hybrid PET/MRI systems. MRI requires negligible RF interference at the Larmor resonance frequency, while RF interference at almost any frequency may corrupt PET data. Moreover, any scheme that minimizes these interactions would, ideally, not compromise the performance of either subsystem. This paper lays out a plan to resolve these problems. A carbon fiber composite material is found to be a good RF shield at the Larmor frequency (300 MHz in this work) while introducing negligible gradient eddy currents. This carbon fiber composite also provides excellent structural support for the PET detector components. Low frequency electromagnetic radiation (81 kHz here) from the switching power supplies of the gradient amplifiers was also found to interfere with the PET detector. Placing the PET detector module between two carbon fiber tubes and grounding the inner carbon fiber tube to the PET detector module ground reduced this interference. Further reductions were achieved by adding thin copper (Cu) foil on the outer carbon fiber case and electrically grounding the PET detector module so that all 3 components had a common ground, i.e. with the PET detector in an electrostatic cage. Finally, gradient switching typical in MRI sequences can result in count losses in the particular PET detector design studied. Moreover, the magnitude of this effect depends on the location of the detector within the magnet bore and which MRI gradient is being switched. These findings have a bearing on future designs of PET/MRI systems. PMID:24380812

  19. A colorimetric sensor based on anodized aluminum oxide (AAO) substrate for the detection of nitroaromatics.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Y.; Wang, H. H.; Indacochea, J. E.

    2011-12-15

    Simple and low cost colorimetric sensors for explosives detection were explored and developed. Anodized aluminum oxide (AAO) with large surface area through its porous structure and light background color was utilized as the substrate for colorimetric sensors. Fabricated thin AAO films with thickness less than {approx} 500 nm allowed us to observe interference colors which were used as the background color for colorimetric detection. AAO thin films with various thickness and pore-to-pore distance were prepared through anodizing aluminum foils at different voltages and times in dilute sulfuric acid. Various interference colors were observed on these samples due to their differencemore » in structures. Accordingly, suitable anodization conditions that produce AAO samples with desired light background colors for optical applications were obtained. Thin film interference model was applied to analyze the UV-vis reflectance spectra and to estimate the thickness of the AAO membranes. We found that the thickness of produced AAO films increased linearly with anodization time in sulfuric acid. In addition, the growth rate was higher for AAO anodized using higher voltages. The thin film interference formulism was further validated with a well established layer by layer deposition technique. Coating poly(styrene sulfonate) sodium salt (PSS) and poly(allylamine hydrochloride) (PAH) layer by layer on AAO thin film consistently shifted its surface color toward red due to the increase in thickness. The red shift of UV-vis reflectance was correlated quantitatively to the number of layers been assembled. This sensitive red shift due to molecular attachment (increase in thickness) on AAO substrate was applied toward nitroaromatics detection. Aminopropyltrimethoxysilane (APTS) which can be attached onto AAO nanowells covalently through silanization and attract TNT molecules was coated and applied for TNT detection. UV-vis spectra of AAO with APTS shifted to the longer wavelength side due to TNT attachment. This red shift implied AAO thickness increased and positive detection of TNT molecules. It was also observed that both APTS and polyethyleneimine (PEI) were electron rich polymers which formed Meisenheimer complexes with TNT in solution and changed its color abruptly. This strong color change due to chemical reaction was applied as another approach for direct TNT detection. Commercial AAO films with long pores (60 {mu}m) and white background color were coated with APTS or PEI and then exposed to TNT in solution. These membranes turned to pink rapidly and eventually became visibly orange after a few hours with a strong absorption around 500 nm that was consistent with the formation of Meisenheimer complexes. The visible color change can be observed by unaided eyes and is suitable for nitroaromatics detection at higher concentration while interference color red shift in AAO thin film is designed for nitroaromatics detection at monolayer (nm) level.« less

  20. Self-Orientation Modulates the Neural Correlates of Global and Local Processing

    PubMed Central

    Liddell, Belinda J.; Das, Pritha; Battaglini, Eva; Malhi, Gin S.; Felmingham, Kim L.; Whitford, Thomas J.; Bryant, Richard A.

    2015-01-01

    Differences in self-orientation (or “self-construal”) may affect how the visual environment is attended, but the neural and cultural mechanisms that drive this remain unclear. Behavioral studies have demonstrated that people from Western backgrounds with predominant individualistic values are perceptually biased towards local-level information; whereas people from non-Western backgrounds that support collectivist values are preferentially focused on contextual and global-level information. In this study, we compared two groups differing in predominant individualistic (N = 15) vs collectivistic (N = 15) self-orientation. Participants completed a global/local perceptual conflict task whilst undergoing functional Magnetic Resonance Imaging (fMRI) scanning. When participants high in individualistic values attended to the global level (ignoring the local level), greater activity was observed in the frontoparietal and cingulo-opercular networks that underpin attentional control, compared to the match (congruent) baseline. Participants high in collectivistic values activated similar attentional control networks o only when directly compared with global processing. This suggests that global interference was stronger than local interference in the conflict task in the collectivistic group. Both groups showed increased activity in dorsolateral prefrontal regions involved in resolving perceptual conflict during heightened distractor interference. The findings suggest that self-orientation may play an important role in driving attention networks to facilitate interaction with the visual environment. PMID:26270820

  1. Self-Orientation Modulates the Neural Correlates of Global and Local Processing.

    PubMed

    Liddell, Belinda J; Das, Pritha; Battaglini, Eva; Malhi, Gin S; Felmingham, Kim L; Whitford, Thomas J; Bryant, Richard A

    2015-01-01

    Differences in self-orientation (or "self-construal") may affect how the visual environment is attended, but the neural and cultural mechanisms that drive this remain unclear. Behavioral studies have demonstrated that people from Western backgrounds with predominant individualistic values are perceptually biased towards local-level information; whereas people from non-Western backgrounds that support collectivist values are preferentially focused on contextual and global-level information. In this study, we compared two groups differing in predominant individualistic (N = 15) vs collectivistic (N = 15) self-orientation. Participants completed a global/local perceptual conflict task whilst undergoing functional Magnetic Resonance Imaging (fMRI) scanning. When participants high in individualistic values attended to the global level (ignoring the local level), greater activity was observed in the frontoparietal and cingulo-opercular networks that underpin attentional control, compared to the match (congruent) baseline. Participants high in collectivistic values activated similar attentional control networks o only when directly compared with global processing. This suggests that global interference was stronger than local interference in the conflict task in the collectivistic group. Both groups showed increased activity in dorsolateral prefrontal regions involved in resolving perceptual conflict during heightened distractor interference. The findings suggest that self-orientation may play an important role in driving attention networks to facilitate interaction with the visual environment.

  2. Design principles of the LVT-2 model laser instrument for the measurement of visual characteristics

    NASA Astrophysics Data System (ADS)

    Sun, Wende

    1989-10-01

    As far as the LVT-2 model laser visual acuity measuring instrument, after its model improvement, is concerned, it not only is capable of measuring the visual acuity of retina (LVA), but also capable of measuring the MTF of retina. The light path system of the instrument has three sections. One is a double light bundle common path interference system making use of double Dufu prisms to divide bundles. In conjunction with this, it uses the movement of a reflection lens M2 in order to change the interval distance of the two mutually interfering bundles. As a result of this, it changes the spacial frequency of the interference bands. This acts as the light path to measure LVA. The second is the background light set composed of such components as the tungsten filament lamp T sub L, the interference filter optical plate OF, and the polarization lens P2. It is used in order to form, on the retina, a uniform background base light. In conjunction with this, through adjustments of the dispersion prism B in the light path, adjustments are made in the degree of contrast change I sub O/I sub u measuring the MTF of the retina.

  3. The design of an experiment to detect low energy antiprotons

    NASA Technical Reports Server (NTRS)

    Lloyd-Evans, J.; Acharya, B. S.; Balasubrahmanyan, V. K.; Ormes, J. F.; Streitmatter, R. E.; Stephens, S. A.

    1985-01-01

    The techniques to be used in a balloon borne experiment APEX to detect 220 MeV antiprotons are described, paying particular attention to potential sources of background. Event time history is shown to be very effective in eliminating this background. Results of laboratory tests on the timing resolution which may be achieved are presented.

  4. Multimodal technique to eliminate humidity interference for specific detection of ethanol.

    PubMed

    Jalal, Ahmed Hasnain; Umasankar, Yogeswaran; Gonzalez, Pablo J; Alfonso, Alejandro; Bhansali, Shekhar

    2017-01-15

    Multimodal electrochemical technique incorporating both open circuit potential (OCP) and amperometric techniques have been conceptualized and implemented to improve the detection of specific analyte in systems where more than one analyte is present. This approach has been demonstrated through the detection of ethanol while eliminating the contribution of water in a micro fuel cell sensor system. The sensor was interfaced with LMP91000 potentiostat, controlled through MSP430F5529LP microcontroller to implement an auto-calibration algorithm tailored to improve the detection of alcohol. The sensor was designed and fabricated as a three electrode system with Nafion as a proton exchange membrane (PEM). The electrochemical signal of the interfering phase (water) was eliminated by implementing the multimodal electrochemical detection technique. The results were validated by comparing sensor and potentiostat performances with a commercial sensor and potentiostat respectively. The results suggest that such a sensing system can detect ethanol at concentrations as low as 5ppm. The structure and properties such as low detection limit, selectivity and miniaturized size enables potential application of this device in wearable transdermal alcohol measurements. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Impact of substrate etching on plasmonic elements and metamaterials: preventing red shift and improving refractive index sensitivity.

    PubMed

    Moritake, Yuto; Tanaka, Takuo

    2018-02-05

    We propose and demonstrate the elimination of substrate influence on plasmon resonance by using selective and isotropic etching of substrates. Preventing the red shift of the resonance due to substrates and improving refractive index sensitivity were experimentally demonstrated by using plasmonic nanostructures fabricated on silicon substrates. Applying substrate etching decreases the effective refractive index around the metal nanostructures, resulting in elimination of the red shift. Improvement of sensitivity to the refractive index environment was demonstrated by using plasmonic metamaterials with Fano resonance based on far field interference. Change in quality factors (Q-factors) of the Fano resonance by substrate etching was also investigated in detail. The presence of a closely positioned substrate distorts the electric field distribution and degrades the Q-factors. Substrate etching dramatically increased the refractive index sensitivity reaching to 1532 nm/RIU since the electric fields under the nanostructures became accessible through substrate etching. The FOM was improved compared to the case without the substrate etching. The method presented in this paper is applicable to a variety of plasmonic structures to eliminate the influence of substrates for realizing high performance plasmonic devices.

  6. Pain Intensity Moderates the Relationship Between Age and Pain Interference in Chronic Orofacial Pain Patients.

    PubMed

    Boggero, Ian A; Geiger, Paul J; Segerstrom, Suzanne C; Carlson, Charles R

    2015-01-01

    BACKGROUND/STUDY CONTEXT: Chronic pain is associated with increased interference in daily functioning that becomes more pronounced as pain intensity increases. Based on previous research showing that older adults maintain well-being in the face of pain as well as or better than their younger counterparts, the current study examined the interaction of age and pain intensity on interference in a sample of chronic orofacial pain patients. Data were obtained from the records of 508 chronic orofacial pain patients being seen for an initial evaluation from 2008 to 2012. Collected data included age (range: 18-78) and self-reported measures of pain intensity and pain interference. Bivariate correlations and regression models were used to assess for statistical interactions. Regression analyses revealed that pain intensity positively predicted pain interference (R(2) = .35, B = 10.40, SE = 0.62, t(507) = 16.70, p < .001). A significant interaction supported the primary hypothesis that aging was associated with reduced interference at high levels of pain intensity (ΔR(2) = .01, B = -1.31, SE = 0.63, t(505) = -2.90, p = .04). At high levels of pain intensity, interference decreased with age, although the age by pain intensity interaction effect was small. This evidence converges with aging theories, including socioemotional selectivity theory, which posits that as people age, they become more motivated to maximize positive emotions and minimize negative ones. The results highlight the importance of studying the mechanisms older adults use to successfully cope with pain.

  7. Fundamentals of electrochemical detection techniques for CE and MCE.

    PubMed

    Kubán, Pavel; Hauser, Peter C

    2009-10-01

    The electroanalytical techniques of amperometry, conductometry and potentiometry match well with the instrumental simplicity of CE. Indeed, all three detection approaches have been reported for electrophoretic separations. However, the characteristics of the three methods are quite distinct and these are not related to the optical methods more commonly employed. A detailed discussion of the underlying principles of each is given. The issue of possible effects of the separation voltage on the electrochemical detection techniques is considered in depth, and approaches to the elimination of such interferences are also discussed for each case.

  8. Method for rapidly determining a pulp kappa number using spectrophotometry

    DOEpatents

    Chai, Xin-Sheng; Zhu, Jun Yong

    2002-01-01

    A system and method for rapidly determining the pulp kappa number through direct measurement of the potassium permanganate concentration in a pulp-permanganate solution using spectrophotometry. Specifically, the present invention uses strong acidification to carry out the pulp-permanganate oxidation reaction in the pulp-permanganate solution to prevent the precipitation of manganese dioxide (MnO.sub.2). Consequently, spectral interference from the precipitated MnO.sub.2 is eliminated and the oxidation reaction becomes dominant. The spectral intensity of the oxidation reaction is then analyzed to determine the pulp kappa number.

  9. Readout for phase qubits without Josephson junctions

    NASA Astrophysics Data System (ADS)

    Steffen, Matthias; Kumar, Shwetank; DiVincenzo, David; Keefe, George; Ketchen, Mark; Rothwell, Mary Beth; Rozen, Jim

    2010-03-01

    We present a readout scheme for phase qubits which eliminates the read-out superconducting quantum interference device so that the entire qubit and measurement circuitry only require a single Josephson junction. Our scheme capacitively couples the phase qubit directly to a transmission line and detects its state after the measurement pulse by determining a frequency shift observable in the forward scattering parameter of the readout microwaves. This readout is extendable to multiple phase qubits coupled to a common readout line and can in principle be used for other flux biased qubits having two quasistable readout configurations.

  10. Electronic heterodyne recording and processing of optical holograms using phase modulated reference waves

    NASA Technical Reports Server (NTRS)

    Decker, A. J.; Pao, Y.-H.; Claspy, P. C.

    1978-01-01

    The use of a phase-modulated reference wave for the electronic heterodyne recording and processing of a hologram is described. Heterodyne recording is used to eliminate the self-interference terms of a hologram and to create a Leith-Upatnieks hologram with coaxial object and reference waves. Phase modulation is also shown to be the foundation of a multiple-view hologram system. When combined with hologram scale transformations, heterodyne recording is the key to general optical processing. Spatial filtering is treated as an example.

  11. TRAIL-induced programmed necrosis as a novel approach to eliminate tumor cells

    PubMed Central

    2014-01-01

    Background The cytokine TRAIL represents one of the most promising candidates for the apoptotic elimination of tumor cells, either alone or in combination therapies. However, its efficacy is often limited by intrinsic or acquired resistance of tumor cells to apoptosis. Programmed necrosis is an alternative, molecularly distinct mode of programmed cell death that is elicited by TRAIL under conditions when the classical apoptosis machinery fails or is actively inhibited. The potential of TRAIL-induced programmed necrosis in tumor therapy is, however, almost completely uncharacterized. We therefore investigated its impact on a panel of tumor cell lines of wide-ranging origin. Methods Cell death/viability was measured by flow cytometry/determination of intracellular ATP levels/crystal violet staining. Cell surface expression of TRAIL receptors was detected by flow cytometry, expression of proteins by Western blot. Ceramide levels were quantified by high-performance thin layer chromatography and densitometric analysis, clonogenic survival of cells was determined by crystal violet staining or by soft agarose cloning. Results TRAIL-induced programmed necrosis killed eight out of 14 tumor cell lines. Clonogenic survival was reduced in all sensitive and even one resistant cell lines tested. TRAIL synergized with chemotherapeutics in killing tumor cell lines by programmed necrosis, enhancing their effect in eight out of 10 tested tumor cell lines and in 41 out of 80 chemotherapeutic/TRAIL combinations. Susceptibility/resistance of the investigated tumor cell lines to programmed necrosis seems to primarily depend on expression of the pro-necrotic kinase RIPK3 rather than the related kinase RIPK1 or cell surface expression of TRAIL receptors. Furthermore, interference with production of the lipid ceramide protected all tested tumor cell lines. Conclusions Our study provides evidence that TRAIL-induced programmed necrosis represents a feasible approach for the elimination of tumor cells, and that this treatment may represent a promising new option for the future development of combination therapies. Our data also suggest that RIPK3 expression may serve as a potential predictive marker for the sensitivity of tumor cells to programmed necrosis and extend the previously established role of ceramide as a key mediator of death receptor-induced programmed necrosis (and thus as a potential target for future therapies) also to the tumor cell lines examined here. PMID:24507727

  12. Heterodyne effect in Hybrid CARS

    NASA Astrophysics Data System (ADS)

    Wang, Xi; Zhang, Aihua; Zhi, Miaochan; Sokolov, Alexei; Welch, George; Scully, Marlan

    2009-10-01

    We study the interaction between the resonant Raman signal and non-Raman field, either the concomitant nonresonant four-wave-mixing (FWM) background or an applied external field, in our recently developed scheme of coherent Anti-Stokes Raman scattering, a hybrid CARS. Our technique combines instantaneous coherent excitation of several characteristic molecular vibrations with subsequent probing of these vibrations by an optimally shaped, time-delayed, narrowband laser pulse. This pulse configuration mitigates the non-resonant FWM background while maximizing the Raman-resonant signal, and allows rapid and highly specific detection even in the presence of multiple scattering. We apply this method to non-invasive monitoring of blood glucose levels. Under certain conditions we find that the measured signal is linearly proportional to the glucose concentration due to optical interference with the residual background light, which allows reliable detection of spectral signatures down to medically-relevant glucose levels. We also study the interference between the CARS field and an external field (the local oscillator) by controlling their relative phase and amplitude. This control allows direct observation of the real and imaginary components of the third-order nonlinear susceptibility (χ^(3)) of the sample. We demonstrate that the heterodyne method can be used to amplify the signal and thus increase detection sensitivity.

  13. Probing the Higgs couplings to photons in h→4ℓ at the LHC.

    PubMed

    Chen, Yi; Harnik, Roni; Vega-Morales, Roberto

    2014-11-07

    We explore the sensitivity of the Higgs decay to four leptons, the so-called golden channel, to higher dimensional loop-induced couplings of the Higgs boson to ZZ, Zγ, and γγ pairs, allowing for general CP mixtures. The larger standard model tree level coupling hZ(μ)Z(μ) is the dominant "background" for the loop-induced couplings. However, this large background interferes with the smaller loop-induced couplings, enhancing the sensitivity. We perform a maximum likelihood analysis based on analytic expressions of the fully differential decay width for h→4ℓ (4ℓ≡2e2μ,4e,4μ), including all interference effects. We find that the spectral shapes induced by Higgs couplings to photons are particularly different than the hZ(μ)Z(μ) background leading to enhanced sensitivity to these couplings. We show that even if the h→γγ and h→4ℓ rates agree with that predicted by the standard model, the golden channel has the potential to probe both the CP nature as well as the overall sign of the Higgs coupling to photons well before the end of a high-luminosity LHC.

  14. A Narrow-Linewidth Atomic Line Filter for Free Space Quantum Key Distribution under Daytime Atmospheric Conditions

    NASA Astrophysics Data System (ADS)

    Brown, Justin; Woolf, David; Hensley, Joel

    2016-05-01

    Quantum key distribution can provide secure optical data links using the established BB84 protocol, though solar backgrounds severely limit the performance through free space. Several approaches to reduce the solar background include time-gating the photon signal, limiting the field of view through geometrical design of the optical system, and spectral rejection using interference filters. Despite optimization of these parameters, the solar background continues to dominate under daytime atmospheric conditions. We demonstrate an improved spectral filter by replacing the interference filter (Δν ~ 50 GHz) with an atomic line filter (Δν ~ 1 GHz) based on optical rotation of linearly polarized light through a warm Rb vapor. By controlling the magnetic field and the optical depth of the vapor, a spectrally narrow region can be transmitted between crossed polarizers. We find that the transmission is more complex than a single peak and evaluate peak transmission as well as a ratio of peak transmission to average transmission of the local spectrum. We compare filters containing a natural abundance of Rb with those containing isotopically pure 87 Rb and 85 Rb. A filter providing > 95 % transmission and Δν ~ 1.1 GHz is achieved.

  15. Exploiting vibrational resonance in weak-signal detection

    NASA Astrophysics Data System (ADS)

    Ren, Yuhao; Pan, Yan; Duan, Fabing; Chapeau-Blondeau, François; Abbott, Derek

    2017-08-01

    In this paper, we investigate the first exploitation of the vibrational resonance (VR) effect to detect weak signals in the presence of strong background noise. By injecting a series of sinusoidal interference signals of the same amplitude but with different frequencies into a generalized correlation detector, we show that the detection probability can be maximized at an appropriate interference amplitude. Based on a dual-Dirac probability density model, we compare the VR method with the stochastic resonance approach via adding dichotomous noise. The compared results indicate that the VR method can achieve a higher detection probability for a wider variety of noise distributions.

  16. Pressure Measurements Using an Airborne Differential Absorption Lidar. Part 1; Analysis of the Systematic Error Sources

    NASA Technical Reports Server (NTRS)

    Flamant, Cyrille N.; Schwemmer, Geary K.; Korb, C. Laurence; Evans, Keith D.; Palm, Stephen P.

    1999-01-01

    Remote airborne measurements of the vertical and horizontal structure of the atmospheric pressure field in the lower troposphere are made with an oxygen differential absorption lidar (DIAL). A detailed analysis of this measurement technique is provided which includes corrections for imprecise knowledge of the detector background level, the oxygen absorption fine parameters, and variations in the laser output energy. In addition, we analyze other possible sources of systematic errors including spectral effects related to aerosol and molecular scattering interference by rotational Raman scattering and interference by isotopic oxygen fines.

  17. Exploiting vibrational resonance in weak-signal detection.

    PubMed

    Ren, Yuhao; Pan, Yan; Duan, Fabing; Chapeau-Blondeau, François; Abbott, Derek

    2017-08-01

    In this paper, we investigate the first exploitation of the vibrational resonance (VR) effect to detect weak signals in the presence of strong background noise. By injecting a series of sinusoidal interference signals of the same amplitude but with different frequencies into a generalized correlation detector, we show that the detection probability can be maximized at an appropriate interference amplitude. Based on a dual-Dirac probability density model, we compare the VR method with the stochastic resonance approach via adding dichotomous noise. The compared results indicate that the VR method can achieve a higher detection probability for a wider variety of noise distributions.

  18. Fraunhofer filters to reduce solar background for optical communications

    NASA Technical Reports Server (NTRS)

    Kerr, E. L.

    1986-01-01

    A wavelength that lies within a spectral interval of reduced solar emission (a Fraunhofer line) can carry optical communications with reduced interference from direct or reflected background sunlight. Suitable Fraunhofer lines are located within the tuning range of good candidate lasers. The laser should be tunable dynamically to track Doppler shifts in the sunlight incident on any solar system body that may appear in the background as viewed by the receiver. A Fraunhofer filter used with a direct-detection receiver should be tuned to match the Doppler shifts of the source and background. The required tuning calculated here for various situations is also required if, instead, one uses a heterodyne receiver with limited post-detection bandwidth.

  19. The PRP Effect Following Callosotomy: Residual Interference Despite Uncoupling of Lateralized Response Codes

    NASA Technical Reports Server (NTRS)

    Ivry, Richard B.; Franz, Elizabeth A.; Kingstone, Alan; Johnston, James C.; Null, Cynthia H. (Technical Monitor)

    1995-01-01

    A callosotomy patient was tested in two dual-task experiments requiring successive speeded responses to lateralized stimuli. In accord with the recent findings of Pashler, O'Brien, Luck, Hillyard, Mangun, and Gazzaniga (in press), the patient showed a robust psychological refractory period effect (PRP) responses on Task 2 were inversely related to the stimulus-onset asynchrony (SOA). However, three aspects of our data indicated that the processing limitations for the patient were different than those observed with control subjects. First, the split-brain patient did not show an increase in reaction time when the two tasks required responses from a common output system (i.e., both manual responses) in comparison to when different output systems were used (i.e., manual-vocal). Second, inconsistent stimulus-response mappings for the two tasks greatly inflated response latencies for the control subjects, but had minimal effect on the performance of the split-brain patient. Third, the consistency manipulation was underadditive with SOA for only the patient, suggesting a later bottleneck in processing following callosotomy than was observed for the control subjects. It is proposed that sectioning the corpus callosum eliminates interference resulting from competing stimulus response codes. Nonetheless, dual-task interference persists for the split-brain subject because a subcortical gate constrains when selected responses can be implemented.

  20. Development and evaluation of optical fiber NH3 sensors for application in air quality monitoring

    NASA Astrophysics Data System (ADS)

    Huang, Yu; Wieck, Lucas; Tao, Shiquan

    2013-02-01

    Ammonia is a major air pollutant emitted from agricultural practices. Sources of ammonia include manure from animal feeding operations and fertilizer from cropping systems. Sensor technologies with capability of continuous real time monitoring of ammonia concentration in air are needed to qualify ammonia emissions from agricultural activities and further evaluate human and animal health effects, study ammonia environmental chemistry, and provide baseline data for air quality standard. We have developed fiber optic ammonia sensors using different sensing reagents and different polymers for immobilizing sensing reagents. The reversible fiber optic sensors have detection limits down to low ppbv levels. The response time of these sensors ranges from seconds to tens minutes depending on transducer design. In this paper, we report our results in the development and evaluation of fiber optic sensor technologies for air quality monitoring. The effect of change of temperature, humidity and carbon dioxide concentration on fiber optic ammonia sensors has been investigated. Carbon dioxide in air was found not interfere the fiber optic sensors for monitoring NH3. However, the change of humidity can cause interferences to some fiber optic NH3 sensors depending on the sensor's transducer design. The sensitivity of fiber optic NH3 sensors was found depends on temperature. Methods and techniques for eliminating these interferences have been proposed.

  1. Decoupling control of vehicle chassis system based on neural network inverse system

    NASA Astrophysics Data System (ADS)

    Wang, Chunyan; Zhao, Wanzhong; Luan, Zhongkai; Gao, Qi; Deng, Ke

    2018-06-01

    Steering and suspension are two important subsystems affecting the handling stability and riding comfort of the chassis system. In order to avoid the interference and coupling of the control channels between active front steering (AFS) and active suspension subsystems (ASS), this paper presents a composite decoupling control method, which consists of a neural network inverse system and a robust controller. The neural network inverse system is composed of a static neural network with several integrators and state feedback of the original chassis system to approach the inverse system of the nonlinear systems. The existence of the inverse system for the chassis system is proved by the reversibility derivation of Interactor algorithm. The robust controller is based on the internal model control (IMC), which is designed to improve the robustness and anti-interference of the decoupled system by adding a pre-compensation controller to the pseudo linear system. The results of the simulation and vehicle test show that the proposed decoupling controller has excellent decoupling performance, which can transform the multivariable system into a number of single input and single output systems, and eliminate the mutual influence and interference. Furthermore, it has satisfactory tracking capability and robust performance, which can improve the comprehensive performance of the chassis system.

  2. Image grating metrology using phase-stepping interferometry in scanning beam interference lithography

    NASA Astrophysics Data System (ADS)

    Li, Minkang; Zhou, Changhe; Wei, Chunlong; Jia, Wei; Lu, Yancong; Xiang, Changcheng; Xiang, XianSong

    2016-10-01

    Large-sized gratings are essential optical elements in laser fusion and space astronomy facilities. Scanning beam interference lithography is an effective method to fabricate large-sized gratings. To minimize the nonlinear phase written into the photo-resist, the image grating must be measured to adjust the left and right beams to interfere at their waists. In this paper, we propose a new method to conduct wavefront metrology based on phase-stepping interferometry. Firstly, a transmission grating is used to combine the two beams to form an interferogram which is recorded by a charge coupled device(CCD). Phase steps are introduced by moving the grating with a linear stage monitored by a laser interferometer. A series of interferograms are recorded as the displacement is measured by the laser interferometer. Secondly, to eliminate the tilt and piston error during the phase stepping, the iterative least square phase shift method is implemented to obtain the wrapped phase. Thirdly, we use the discrete cosine transform least square method to unwrap the phase map. Experiment results indicate that the measured wavefront has a nonlinear phase around 0.05 λ@404.7nm. Finally, as the image grating is acquired, we simulate the print-error written into the photo-resist.

  3. Spectroscopic detection

    DOEpatents

    Woskov, Paul P.; Hadidi, Kamal

    2003-01-01

    In embodiments, spectroscopic monitor monitors modulated light signals to detect low levels of contaminants and other compounds in the presence of background interference. The monitor uses a spectrometer that includes a transmissive modulator capable of causing different frequency ranges to move onto and off of the detector. The different ranges can include those with the desired signal and those selected to subtract background contributions from those with the desired signal. Embodiments of the system are particularly useful for monitoring metal concentrations in combustion effluent.

  4. The Use of Pre-Lectures in a University Biology Course--Eliminating the Need for Prerequisites

    ERIC Educational Resources Information Center

    da Silva, Karen Burke; Hunter, Narelle

    2009-01-01

    First year biology students at Flinders University with no prior biology background knowledge fail at almost twice the rate as those with a background. To remedy this discrepancy we enabled students to attend a weekly series of pre-lectures aimed at providing basic biological concepts, thereby removing the need for students to complete a…

  5. The Efficacy of the Canter Background Interference Procedure in Identifying Children with Cerebral Dysfunction

    ERIC Educational Resources Information Center

    Adams, Jerry; Kenny, Thomas J.

    1973-01-01

    In this study, BIP records previously reported by Kenny (1971) were reused to determine the accuracy of identification of children with cerebral dysfunction and to update the results of using the revised BIP scoring system. (Author)

  6. Measurement of 224Ra and 226Ra activities in natural waters using a radon-in-air monitor

    USGS Publications Warehouse

    Kim, G.; Burnett, W.C.; Dulaiova, H.; Swarzenski, P.W.; Moore, W.S.

    2001-01-01

    We report a simple new technique for measuring low-level radium isotopes (224Ra and 226Ra) in natural waters. The radium present in natural waters is first preconcentrated onto MnO2-coated acrylic fiber (Mn fiber) in a column mode. The radon produced from the adsorbed radium is then circulated through a closed air-loop connected to a commercial radon-in-air monitor. The monitor counts alpha decays of radon daughters (polonium isotopes) which are electrostatically collected onto a silicon semiconductor detector. Count data are collected in energy-specific windows, which eliminate interference and maintain very low backgrounds. Radium-224 is measured immediately after sampling via 220Rn (216Po), and 226Ra is measured via 222Rn (218Po) after a few days of ingrowth of 222Rn. This technique is rapid, simple, and accurate for measurements of low-level 224Ra and 226Ra activities without requiring any wet chemistry. Rapid measurements of short-lived 222Rn and 224Ra, along with long-lived 226Ra, may thus be made in natural waters using a single portable system for environmental monitoring of radioactivity as well as tracing of various geochemical and geophysical processes. The technique could be especially useful for the on-site rapid determination of 224Ra which has recently been found to occur at elevated activities in some groundwater wells.

  7. Lab-on-a-bubble: direct and indirect assays with portable Raman instrumentation

    NASA Astrophysics Data System (ADS)

    Carron, Keith; Schmit, Virginia; Scott, Brandon; Martoglio, Richard

    2012-10-01

    Lab-on-a-Bubble (LoB) is a new method for SERS (Surface Enhanced Raman Scattering) assays that combines separationand concentration of the assay results. A direct LoB assay is comprised of gold nanoparticles coupled directly to the ~30 μm diameter buoyant silica bubble. The direct LoB method was evaluated with cyanide and 5,5'-dithiobis(2-nitrobenzoic acid) (DTNB). An indirect assay uses the same ~ 30 μm diameter buoyant silica bubble and a silica coated SERS reporter. Both the bubble and SERS reporter are coated with a coupling agent for the analyte. The assay measures the amount of SERS reporter coupled to the bubble through a sandwich created by the analyte. The couling agent could consist of an immunological coupling agent (antibody) or a nucleic acid coupling agent (single strand DNA). The indirect LoB method was examined with Cholera toxin (CT) and antibodies against the β subunit. An LOD of ~ 170 pptrillion was measured for cyanide and a limit of detection of 1100 ng was found for CT. Instrumentation for the assay and a novel technique of dynamic SERS (DSERS) will also be discussed. The instrument is a small hand-held Raman device called the CBEx (Chemical Biological Explosive) with a novel raster system to detect heterogeneous or light sensitive materials. DSERS is a mathematical algorithm which eliminates background interference in SERS measurements with colloidal nanoparticles.

  8. Electron-excited energy dispersive X-ray spectrometry at high speed and at high resolution: silicon drift detectors and microcalorimeters.

    PubMed

    Newbury, Dale E

    2006-12-01

    Two recent developments in X-ray spectrometer technology provide dramatic improvements in analytical capabilities that impact the frontiers of electron microscopy. Silicon drift detectors (SDD) use the same physics as silicon (lithium) energy dispersive spectrometers [Si(Li) EDS] but differ in design: only 10% of the thickness of the Si(Li) EDS with an anode area below 0.1 mm2 and a complex rear surface electrode pattern that creates a lateral internal charge collection field. The SDD equals or betters the Si(Li) EDS in most measures of performance. For output versus input count rate, the SDD exceeds the Si(Li) EDS by a factor of 5 to 10 for the same resolution. This high throughput can benefit analytical measurements that are count limited, such as X-ray mapping and trace measurements. The microcalorimeter EDS determines the X-ray energy by measuring the temperature rise in a metal absorber. Operating at 100 mK, the microcalorimeter EDS achieves resolution of 2-5 eV over a photon energy range of 200 eV to 10 keV in energy dispersive operation, eliminating most peak interference situations and providing high peak-to-background to detect low fluorescence yield peaks. Chemical bonding effects on low energy (< 2 keV) peak shapes can be measured.

  9. Enzyme-modified carbon-fiber microelectrode for the quantification of dynamic fluctuations of nonelectroactive analytes using fast-scan cyclic voltammetry.

    PubMed

    Lugo-Morales, Leyda Z; Loziuk, Philip L; Corder, Amanda K; Toups, J Vincent; Roberts, James G; McCaffrey, Katherine A; Sombers, Leslie A

    2013-09-17

    Neurotransmission occurs on a millisecond time scale, but conventional methods for monitoring nonelectroactive neurochemicals are limited by slow sampling rates. Despite a significant global market, a sensor capable of measuring the dynamics of rapidly fluctuating, nonelectroactive molecules at a single recording site with high sensitivity, electrochemical selectivity, and a subsecond response time is still lacking. To address this need, we have enabled the real-time detection of dynamic glucose fluctuations in live brain tissue using background-subtracted, fast-scan cyclic voltammetry. The novel microbiosensor consists of a simple carbon fiber surface modified with an electrodeposited chitosan hydrogel encapsulating glucose oxidase. The selectivity afforded by voltammetry enables quantitative and qualitative measurements of enzymatically generated H2O2 without the need for additional strategies to eliminate interfering agents. The microbiosensors possess a sensitivity and limit of detection for glucose of 19.4 ± 0.2 nA mM(-1) and 13.1 ± 0.7 μM, respectively. They are stable, even under deviations from physiological normoxic conditions, and show minimal interference from endogenous electroactive substances. Using this approach, we have quantitatively and selectively monitored pharmacologically evoked glucose fluctuations with unprecedented chemical and spatial resolution. Furthermore, this novel biosensing strategy is widely applicable to the immobilization of any H2O2 producing enzyme, enabling rapid monitoring of many nonelectroactive enzyme substrates.

  10. Photoswitching Near-Infrared Fluorescence from Polymer Nanoparticles Catapults Signals over the Region of Noises and Interferences for Enhanced Sensitivity.

    PubMed

    Wang, Jie; Lv, Yanlin; Wan, Wei; Wang, Xuefei; Li, Alexander D Q; Tian, Zhiyuan

    2016-02-01

    As a very sensitive technique, photoswitchable fluorescence not only gains ultrasensitivity but also imparts many novel and unexpected applications. Applications of near-infrared (NIR) fluorescence have demonstrated low background noises, high tissue-penetrating ability, and an ability to reduce photodamage to live cells. Because of these desired features, NIR-fluorescent dyes have been the premium among fluorescent dyes, and probes with photoswitchable NIR fluorescence are even more desirable for enhanced signal quality in the emerging optical imaging modalities but rarely used because they are extremely challenging to design and construct. Using a spiropyran derivative functioning as both a photoswitch and a fluorophore to launch its periodically modulated red fluorescence excitation energy into a NIR acceptor, we fabricated core-shell polymer nanoparticles exhibiting a photoswitchable fluorescence signal within the biological window (∼700-1000 nm) with a peak maximum of 776 nm. Live cells constantly synthesize new molecules, including fluorescent molecules, and also endocytose exogenous particles, including fluorescent particles. Upon excitation at different wavelengths, these fluorescent species bring about background noises and interferences covering nearly the whole visible region and therefore render many intracellular targets unaddressable. The oscillating NIR fluorescence signal with an on/off ratio of up to 67 that the polymer nanoparticles display is beyond the typical background noises and interferences, thus producing superior sharpness, reliability, and signal-to-noise ratios in cellular imaging. Taking these salient features, we anticipate that these types of nanoparticles will be useful for in vivo imaging of biological tissue and other complex specimens, where two-photon activation and excitation are used in combination with NIR-fluorescence photoswitching.

  11. Restoration of longitudinal laser tomography target image from inhomogeneous medium degradation under common conditions.

    PubMed

    Yi, WenJun; Wang, Ping; Fu, MeiCheng; Tan, JiChun; Zhu, Jubo; Li, XiuJian

    2017-07-10

    In order to overcome the shortages of the target image restoration method for longitudinal laser tomography using self-calibration, a more general restoration method through backscattering medium images associated with prior parameters is developed for common conditions. The system parameters are extracted from pre-calibration, and the LIDAR ratio is estimated according to the medium types. Assisted by these prior parameters, the degradation caused by inhomogeneous turbid media can be established with the backscattering medium images, which can further be used for removal of the interferences of turbid media. The results of simulations and experiments demonstrate that the proposed image restoration method can effectively eliminate the inhomogeneous interferences of turbid media and achieve exactly the reflectivity distribution of targets behind inhomogeneous turbid media. Furthermore, the restoration method can work beyond the limitation of the previous method that only works well under the conditions of localized turbid attenuations and some types of targets with fairly uniform reflectivity distributions.

  12. A 4-channel coil array interconnection by analog direct modulation optical link for 1.5-T MRI.

    PubMed

    Yuan, Jing; Wei, Juan; Shen, Gary X

    2008-10-01

    Optical glass fiber shows great advantages over coaxial cables in terms of electromagnetic interference, thus, it should be considered a potential alternative for magnetic resonance imaging (MRI) receive coil interconnection, especially for a large number coil array at high field. In this paper, we propose a 4-channel analog direct modulation optical link for a 1.5-T MRI coil array interconnection. First, a general direct modulated optical link is compared to an external modulated optical link. And then the link performances of the proposed direct modulated optical link, including power gain, frequency response, and dynamic range, are analyzed and measured. Phantom and in vivo head images obtained using this optical link are demonstrated for comparison with those obtained by cable connections. The signal-to-noise (SNR) analysis shows that the optical link achieves 6%-8% SNR a improvement over coaxial cables by elimination of electrical interference between cables during MR signal transmission.

  13. Optical-fiber-coupled inferometric measurement of tympanic membrane temperature: a new diagnostic tool for acute otitis media

    NASA Astrophysics Data System (ADS)

    DeRowe, Ari; Ophir, Eyal; Sade, Sharon; Fishman, Gadi; Ophir, Dov; Grankin, Mila; Katzir, Abraham

    1998-07-01

    A novel infrared (IR) transparent optical fiber coupled to a hand held otoscope and a radiometer was constructed and used to measure the temperatures of the tympanic membrane (TM) and to distinguish between diseased and healthy middle ears. A greater temperature difference between TM readings was found when Acute Otitis Media (AOM) existed in one of the ears examined. This supports the hypothesis that acute inflammation of the middle ear will result in elevated local temperature when measured in such a way that the reading is taken only from the TM without interference of the external canal. The use of an optical fiber enabled temperature measurements of the TM with high spatial resolution eliminating the external ear canal interference. A small patient population was examined and the initial results were statistically significant. In the hands of the primary care physician, this tool would prevent misdiagnosis of AOM preventing indiscriminate use of antibiotics and avoiding complications by early diagnosis.

  14. Coordinate interferometric system for measuring the position of a sample with infrared telecom laser diode

    NASA Astrophysics Data System (ADS)

    Holá, Miroslava; Lazar, Josef; Čížek, Martin; Hucl, Václav; Řeřucha, Šimon; Číp, Ondřej

    2016-11-01

    We report on a design of an interferometric position measuring system for control of a sample stage in an e-beam writer with reproducibility of the position on nanometer level and resolution below nanometer. We introduced differential configuration of the interferometer where the position is measured with respect to a central reference point to eliminate deformations caused by thermal and pressure effects on the vacuum chamber. The reference is here the electron gun of the writer. The interferometer is designed to operate at infrared, telecommunication wavelength due to the risk of interference of stray light with sensitive photodetectors in the chamber. The laser source is here a narrow-linewidth DFB laser diode with electronics of our own design offering precision and stability of temperature and current, low-noise, protection from rf interference, and high-frequency modulation. Detection of the interferometric signal relies on a novel derivative technique utilizing hf frequency modulation and phase-sensitive detection.

  15. Theoretical and Experimental Study on Wide Range Optical Fiber Turbine Flow Sensor.

    PubMed

    Du, Yuhuan; Guo, Yingqing

    2016-07-15

    In this paper, a novel fiber turbine flow sensor was proposed and demonstrated for liquid measurement with optical fiber, using light intensity modulation to measure the turbine rotational speed for converting to flow rate. The double-circle-coaxial (DCC) fiber probe was introduced in frequency measurement for the first time. Through the divided ratio of two rings light intensity, the interference in light signals acquisition can be eliminated. To predict the characteristics between the output frequency and flow in the nonlinear range, the turbine flow sensor model was built. Via analyzing the characteristics of turbine flow sensor, piecewise linear equations were achieved in expanding the flow measurement range. Furthermore, the experimental verification was tested. The results showed that the flow range ratio of DN20 turbine flow sensor was improved 2.9 times after using piecewise linear in the nonlinear range. Therefore, combining the DCC fiber sensor and piecewise linear method, it can be developed into a strong anti-electromagnetic interference(anti-EMI) and wide range fiber turbine flowmeter.

  16. Encryption of QR code and grayscale image in interference-based scheme with high quality retrieval and silhouette problem removal

    NASA Astrophysics Data System (ADS)

    Qin, Yi; Wang, Hongjuan; Wang, Zhipeng; Gong, Qiong; Wang, Danchen

    2016-09-01

    In optical interference-based encryption (IBE) scheme, the currently available methods have to employ the iterative algorithms in order to encrypt two images and retrieve cross-talk free decrypted images. In this paper, we shall show that this goal can be achieved via an analytical process if one of the two images is QR code. For decryption, the QR code is decrypted in the conventional architecture and the decryption has a noisy appearance. Nevertheless, the robustness of QR code against noise enables the accurate acquisition of its content from the noisy retrieval, as a result of which the primary QR code can be exactly regenerated. Thereafter, a novel optical architecture is proposed to recover the grayscale image by aid of the QR code. In addition, the proposal has totally eliminated the silhouette problem existing in the previous IBE schemes, and its effectiveness and feasibility have been demonstrated by numerical simulations.

  17. Application of derivative spectrophotometry under orthogonal polynomial at unequal intervals: determination of metronidazole and nystatin in their pharmaceutical mixture.

    PubMed

    Korany, Mohamed A; Abdine, Heba H; Ragab, Marwa A A; Aboras, Sara I

    2015-05-15

    This paper discusses a general method for the use of orthogonal polynomials for unequal intervals (OPUI) to eliminate interferences in two-component spectrophotometric analysis. In this paper, a new approach was developed by using first derivative D1 curve instead of absorbance curve to be convoluted using OPUI method for the determination of metronidazole (MTR) and nystatin (NYS) in their mixture. After applying derivative treatment of the absorption data many maxima and minima points appeared giving characteristic shape for each drug allowing the selection of different number of points for the OPUI method for each drug. This allows the specific and selective determination of each drug in presence of the other and in presence of any matrix interference. The method is particularly useful when the two absorption spectra have considerable overlap. The results obtained are encouraging and suggest that the method can be widely applied to similar problems. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. The self streamlining wind tunnel. [wind tunnel walls

    NASA Technical Reports Server (NTRS)

    Goodyer, M. J.

    1975-01-01

    A two dimensional test section in a low speed wind tunnel capable of producing flow conditions free from wall interference is presented. Flexible top and bottom walls, and rigid sidewalls from which models were mounted spanning the tunnel are shown. All walls were unperforated, and the flexible walls were positioned by screw jacks. To eliminate wall interference, the wind tunnel itself supplied the information required in the streamlining process, when run with the model present. Measurements taken at the flexible walls were used by the tunnels computer check wall contours. Suitable adjustments based on streamlining criteria were then suggested by the computer. The streamlining criterion adopted when generating infinite flowfield conditions was a matching of static pressures in the test section at a wall with pressures computed for an imaginary inviscid flowfield passing over the outside of the same wall. Aerodynamic data taken on a cylindrical model operating under high blockage conditions are presented to illustrate the operation of the tunnel in its various modes.

  19. Artifact removal from EEG signals using adaptive filters in cascade

    NASA Astrophysics Data System (ADS)

    Garcés Correa, A.; Laciar, E.; Patiño, H. D.; Valentinuzzi, M. E.

    2007-11-01

    Artifacts in EEG (electroencephalogram) records are caused by various factors, like line interference, EOG (electro-oculogram) and ECG (electrocardiogram). These noise sources increase the difficulty in analyzing the EEG and to obtaining clinical information. For this reason, it is necessary to design specific filters to decrease such artifacts in EEG records. In this paper, a cascade of three adaptive filters based on a least mean squares (LMS) algorithm is proposed. The first one eliminates line interference, the second adaptive filter removes the ECG artifacts and the last one cancels EOG spikes. Each stage uses a finite impulse response (FIR) filter, which adjusts its coefficients to produce an output similar to the artifacts present in the EEG. The proposed cascade adaptive filter was tested in five real EEG records acquired in polysomnographic studies. In all cases, line-frequency, ECG and EOG artifacts were attenuated. It is concluded that the proposed filter reduces the common artifacts present in EEG signals without removing significant information embedded in these records.

  20. The DELTA MONSTER: An RPV designed to investigate the aerodynamics of a delta wing platform

    NASA Technical Reports Server (NTRS)

    Connolly, Kristen; Flynn, Mike; Gallagher, Randy; Greek, Chris; Kozlowski, Marc; Mcdonald, Brian; Mckenna, Matt; Sellar, Rich; Shearon, Andy

    1989-01-01

    The mission requirements for the performance of aerodynamic tests on a delta wind planform posed some problems, these include aerodynamic interference; structural support; data acquisition and transmission instrumentation; aircraft stability and control; and propulsion implementation. To eliminate the problems of wall interference, free stream turbulence, and the difficulty of achieving dynamic similarity between the test and actual flight aircraft that are associated with aerodynamic testing in wind tunnels, the concept of the remotely piloted vehicle which can perform a basic aerodynamic study on a delta wing was the main objective for the Green Mission - the Delta Monster. The basic aerodynamic studies were performed on a delta wing with a sweep angle greater than 45 degrees. These tests were performed at various angles of attack and Reynolds numbers. The delta wing was instrumented to determine the primary leading edge vortex formation and location, using pressure measurements and/or flow visualization. A data acquisition system was provided to collect all necessary data.

  1. High resolution x-ray diffraction analysis of annealed low-temperature gallium arsenide

    NASA Astrophysics Data System (ADS)

    Matyi, R. J.; Melloch, M. R.; Woodall, J. M.

    1992-05-01

    High resolution x-ray diffraction methods have been used to characterize GaAs grown at low substrate temperatures by molecular beam epitaxy and to examine the effects of post-growth annealing on the structure of the layers. Double crystal rocking curves from the as-deposited epitaxial layer show well-defined interference fringes, indicating a high level of structural perfection despite the presence of excess arsenic. Annealing at temperatures from 700 to 900 °C resulted in a decrease in the perpendicular lattice mismatch between the GaAs grown at low temperature and the substrate from 0.133% to 0.016% and a decrease (but not total elimination) of the visibility of the interference fringes. Triple-crystal diffraction scans around the 004 point in reciprocal space exhibited an increase in the apparent mosaic spread of the epitaxial layer with increasing anneal temperature. The observations are explained in terms of the growth of arsenic precipitates in the epitaxial layer.

  2. Theoretical and Experimental Study on Wide Range Optical Fiber Turbine Flow Sensor

    PubMed Central

    Du, Yuhuan; Guo, Yingqing

    2016-01-01

    In this paper, a novel fiber turbine flow sensor was proposed and demonstrated for liquid measurement with optical fiber, using light intensity modulation to measure the turbine rotational speed for converting to flow rate. The double-circle-coaxial (DCC) fiber probe was introduced in frequency measurement for the first time. Through the divided ratio of two rings light intensity, the interference in light signals acquisition can be eliminated. To predict the characteristics between the output frequency and flow in the nonlinear range, the turbine flow sensor model was built. Via analyzing the characteristics of turbine flow sensor, piecewise linear equations were achieved in expanding the flow measurement range. Furthermore, the experimental verification was tested. The results showed that the flow range ratio of DN20 turbine flow sensor was improved 2.9 times after using piecewise linear in the nonlinear range. Therefore, combining the DCC fiber sensor and piecewise linear method, it can be developed into a strong anti-electromagnetic interference(anti-EMI) and wide range fiber turbine flowmeter. PMID:27428976

  3. Rapid Detection of Pathogenic Bacteria from Fresh Produce by Filtration and Surface-Enhanced Raman Spectroscopy

    NASA Astrophysics Data System (ADS)

    Wu, Xiaomeng; Han, Caiqin; Chen, Jing; Huang, Yao-Wen; Zhao, Yiping

    2016-04-01

    The detection of Salmonella Poona from cantaloupe cubes and E. coli O157:H7 from lettuce has been explored by using a filtration method and surface-enhanced Raman spectroscopy (SERS) based on vancomycin-functionalized silver nanorod array substrates. It is found that with a two-step filtration process, the limit of detection (LOD) of Salmonella Poona from cantaloupe cubes can be as low as 100 CFU/mL in less than 4 h, whereas the chlorophyll in the lettuce causes severe SERS spectral interference. To improve the LOD of lettuce, a three-step filtration method with a hydrophobic filter is proposed. The hydrophobic filter can effectively eliminate the interferences from chlorophyll and achieve a LOD of 1000 CFU/mL detection of E. coli O157:H7 from lettuce samples within 5 h. With the low LODs and rapid detection time, the SERS biosensing platform has demonstrated its potential as a rapid, simple, and inexpensive means for pathogenic bacteria detection from fresh produce.

  4. Back-extraction of trace elements from organometallic-halide extracts for determination by flameless atomic absorption spectrometry

    USGS Publications Warehouse

    Clark, J.R.; Viets, J.G.

    1981-01-01

    The Methyl isobutyl ketone-Amine synerGistic Iodkte Complex (MAGIC) extraction system offers the advantage that a large number of trace elements can be rapidly determined with a single sample preparation procedure. However, many of the elements extracted by the MAGIC system form volatile organometallic halide salts when the organic extract is heated in the graphite furnace. High concentrations of some elements such as Cu and Zn extracted by the system from anomalous geological samples produce serious interferences when certain other elements are determined by flameless atomic absorption. Stripping systems have been developed using solutions of HNO3, H2SO4, and CH3COOH individually or combined with H2O2 in order to circumvent these problems. With these systems most of the elements in the organic extract can be sequentially stripped into an aqueous phase. Organometallic volatilization and the most serious interelement interferences, therefore, can be eliminated by stripping with various combinations of reagents in a series of steps.

  5. Standing wave contributions to the linear interference effect in stratosphere-troposphere coupling

    NASA Astrophysics Data System (ADS)

    Watt-Meyer, Oliver; Kushner, Paul

    2014-05-01

    A body of literature by Hayashi and others [Hayashi 1973, 1977, 1979; Pratt, 1976] developed a decomposition of the wavenumber-frequency spectrum into standing and travelling waves. These techniques directly decompose the power spectrum—that is, the amplitudes squared—into standing and travelling parts. This, incorrectly, does not allow for a term representing the covariance between these waves. We propose a simple decomposition based on the 2D Fourier transform which allows one to directly compute the variance of the standing and travelling waves, as well as the covariance between them. Applying this decomposition to geopotential height anomalies in the Northern Hemisphere winter, we show the dominance of standing waves for planetary wavenumbers 1 through 3, especially in the stratosphere, and that wave-1 anomalies have a significant westward travelling component in the high-latitude (60N to 80N) troposphere. Variations in the relative zonal phasing between a wave anomaly and the background climatological wave pattern—the "linear interference" effect—are known to explain a large part of the planetary wave driving of the polar stratosphere in both hemispheres. While the linear interference effect is robust across observations, models of varying degrees of complexity, and in response to various types of perturbations, it is not well understood dynamically. We use the above-described decomposition into standing and travelling waves to investigate the drivers of linear interference. We find that the linear part of the wave activity flux is primarily driven by the standing waves, at all vertical levels. This can be understood by noting that the longitudinal positions of the antinodes of the standing waves are typically close to being aligned with the maximum and minimum of the background climatology. We discuss implications for predictability of wave activity flux, and hence polar vortex strength variability.

  6. Rapid, simultaneous and interference-free determination of three rhodamine dyes illegally added into chilli samples using excitation-emission matrix fluorescence coupled with second-order calibration method.

    PubMed

    Chang, Yue-Yue; Wu, Hai-Long; Fang, Huan; Wang, Tong; Liu, Zhi; Ouyang, Yang-Zi; Ding, Yu-Jie; Yu, Ru-Qin

    2018-06-15

    In this study, a smart and green analytical method based on the second-order calibration algorithm coupled with excitation-emission matrix (EEM) fluorescence was developed for the determination of rhodamine dyes illegally added into chilli samples. The proposed method not only has the advantage of high sensitivity over the traditional fluorescence method but also fully displays the "second-order advantage". Pure signals of analytes were successfully extracted from severely interferential EEMs profiles via using alternating trilinear decomposition (ATLD) algorithm even in the presence of common fluorescence problems such as scattering, peak overlaps and unknown interferences. It is worth noting that the unknown interferents can denote different kinds of backgrounds, not only refer to a constant background. In addition, the method using interpolation method could avoid the information loss of analytes of interest. The use of "mathematical separation" instead of complicated "chemical or physical separation" strategy can be more effective and environmentally friendly. A series of statistical parameters including figures of merit and RSDs of intra- (≤1.9%) and inter-day (≤6.6%) were calculated to validate the accuracy of the proposed method. Furthermore, the authoritative method of HPLC-FLD was adopted to verify the qualitative and quantitative results of the proposed method. Compared with the two methods, it also showed that the ATLD-EEMs method has the advantages of accuracy, rapidness, simplicity and green, which is expected to be developed as an attractive alternative method for simultaneous and interference-free determination of rhodamine dyes illegally added into complex matrices. Copyright © 2018. Published by Elsevier B.V.

  7. Finite fringe hologram

    NASA Technical Reports Server (NTRS)

    Heflinger, L. O.

    1970-01-01

    In holographic interferometry a small movement of apparatus between exposures causes the background of the reconstructed scene to be covered with interference fringes approximately parallel to each other. The three-dimensional quality of the holographic image is allowable since a mathematical model will give the location of the fringes.

  8. Developmental exposure to polychlorinated biphenyls (PCBs) interferes with experience-dependent dendritic plasticity and ryanodine receptor expression in weanling rats.

    EPA Science Inventory

    BACKGROUND: Neurodevelopmental disorders are associated with altered patterns of neuronal connectivity. A critical determinant of neuronal connectivity is the dendritic morphology of individual neurons, which is shaped by experience. The identification of environmental exposures ...

  9. Acousto-optic filtering of lidar signals

    NASA Technical Reports Server (NTRS)

    Kolarov, G.; Deleva, A.; Mitsev, TS.

    1992-01-01

    The predominant part of the noise in lidar receivers is created by the background radiation; therefore, one of the most important elements of the receiving optics is a spectrally selecting filter placed in front of the photodetector. Interference filters are usually used to transmit a given wavelength. Specific properties of the interference filters, such as simple design, reliability, small size, and large aperture, combined with high transmission coefficient and narrow spectral band, make them the preferred spectral device in many cases. However, problems arise in applications such as the Differential Absorption Lidar (DIAL) technique, where fast tuning within a wide spectral region is necessary. Tunable acousto-optical filters (TAOF), used recently in astrophysical observations to suppress the background radiation, can be employed with success in lidar sounding. They are attractive due to the possibility for fast spectral scanning with a narrow transmission band. The TAOF's advantages are fully evident in DIAL lidars where one must simultaneously receive signals at two laser frequencies.

  10. Adaptive suppression of power line interference in ultra-low field magnetic resonance imaging in an unshielded environment.

    PubMed

    Huang, Xiaolei; Dong, Hui; Qiu, Yang; Li, Bo; Tao, Quan; Zhang, Yi; Krause, Hans-Joachim; Offenhäusser, Andreas; Xie, Xiaoming

    2018-01-01

    Power-line harmonic interference and fixed-frequency noise peaks may cause stripe-artifacts in ultra-low field (ULF) magnetic resonance imaging (MRI) in an unshielded environment and in a conductively shielded room. In this paper we describe an adaptive suppression method to eliminate these artifacts in MRI images. This technique utilizes spatial correlation of the interference from different positions, and is realized by subtracting the outputs of the reference channel(s) from those of the signal channel(s) using wavelet analysis and the least squares method. The adaptive suppression method is first implemented to remove the image artifacts in simulation. We then experimentally demonstrate the feasibility of this technique by adding three orthogonal superconducting quantum interference device (SQUID) magnetometers as reference channels to compensate the output of one 2nd-order gradiometer. The experimental results show great improvement in the imaging quality in both 1D and 2D MRI images at two common imaging frequencies, 1.3 kHz and 4.8 kHz. At both frequencies, the effective compensation bandwidth is as high as 2 kHz. Furthermore, we examine the longitudinal relaxation times of the same sample before and after compensation, and show that the MRI properties of the sample did not change after applying adaptive suppression. This technique can effectively increase the imaging bandwidth and be applied to ULF MRI detected by either SQUIDs or Faraday coil in both an unshielded environment and a conductively shielded room. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. Determination of trace elements in dolomite and gypsum by atomic absorption spectrometry: overcoming the matrix interference by flotation separation

    NASA Astrophysics Data System (ADS)

    Stafilov, Trajče; Zendelovska, Dragica; Pavlovska, Gorica; Čundeva, Katarina

    2002-05-01

    The interferences of Ca and Mg as matrix elements in dolomite and gypsum on Ag, Cd, Cr, Mn, Tl and Zn absorbances during their electrothermal atomic absorption spectrometric (ETAAS) determination are investigated. The results reveal that Ca and Mg do not interfere on Zn and Mn, tend to decrease absorbances of Ag, Cd and Cr, while Tl suffers the most significant influence. A flotation separation method is proposed to eliminate matrix interferences. Hydrated iron(III) oxide, Fe 2O 3· xH 2O, and iron(III) hexamethylenedithiocarbamate, Fe(HMDTC) 3, are applied as flotation collectors. The influence of hydrophobic dithiocarbamate anion, HMDTC, on flotation recoveries of each analyte is studied. The most suitable concentrations of dolomite and gypsum solutions for flotation are determined. To avoid flotation suppression due to the reaction of Ca 2+ and Mg 2+ with surfactant ions, a fit foaming agent was selected. The elements present in dolomite and gypsum as traces have been analyzed by ETAAS. Their ETAAS limits of detection following flotation are found to be 0.021 μg·g -1 for Ag, 0.019 μg·g -1 for Cd, 0.014 μg·g -1 for Cr and 0.11 μg·g -1 for Tl. The determination of Mn and Zn can be performed by flame AAS (FAAS). The limit of detection for Mn is 1.5 μg·g -1, while for Zn 0.8 μg·g -1.

  12. 21 CFR 876.1735 - Electrogastrography system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... accessories. (b) Classification. Class II (Special Controls). The special controls are as follows: (1) The... describe how background data should be gathered and used to eliminate artifact in the data signal; (iii) To...

  13. 21 CFR 876.1735 - Electrogastrography system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... accessories. (b) Classification. Class II (Special Controls). The special controls are as follows: (1) The... describe how background data should be gathered and used to eliminate artifact in the data signal; (iii) To...

  14. 21 CFR 876.1735 - Electrogastrography system.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... accessories. (b) Classification. Class II (Special Controls). The special controls are as follows: (1) The... describe how background data should be gathered and used to eliminate artifact in the data signal; (iii) To...

  15. 21 CFR 876.1735 - Electrogastrography system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... accessories. (b) Classification. Class II (Special Controls). The special controls are as follows: (1) The... describe how background data should be gathered and used to eliminate artifact in the data signal; (iii) To...

  16. PAIN INTENSITY MODERATES THE RELATIONSHIP BETWEEN AGE AND PAIN INTERFERENCE IN CHRONIC OROFACIAL PAIN PATIENTS

    PubMed Central

    Boggero, Ian A.; Geiger, Paul J.; Segerstrom, Suzanne C.; Carlson, Charles R.

    2015-01-01

    Background/Study Context Chronic pain is associated with increased interference in daily functioning that becomes more pronounced as pain intensity increases. Based on previous research showing that older adults maintain well-being in the face of pain as well as or better than their younger counterparts, the current study examined the interaction of age and pain intensity on interference in a sample of chronic orofacial pain patients. Methods Data were obtained from the records of 508 chronic orofacial pain patients being seen for an initial evaluation from 2008 to 2012. Collected data included age (range: 18–78) and self-reported measures of pain intensity and pain interference. Bivariate correlations and regression models were used to assess for statistical interactions. Results Regression analyses revealed that pain intensity positively predicted pain interference (R2 = .35, B = 10.40, SE = 0.62, t(507) = 16.70, p < .001). A significant interaction supported the primary hypothesis that aging was associated with reduced interference at high levels of pain intensity (ΔR2 = .01, B = −1.31, SE = 0.63, t(505) = −2.90, p = .04). Conclusion At high levels of pain intensity, interference decreased with age, although the age by pain intensity interaction effect was small. This evidence converges with aging theories, including socioemotional selectivity theory, which posits that as people age, they become more motivated to maximize positive emotions and minimize negative ones. The results highlight the importance of studying the mechanisms older adults use to successfully cope with pain. PMID:26214102

  17. Detecting paraprotein interference on a direct bilirubin assay by reviewing the photometric reaction data.

    PubMed

    García-González, Elena; Aramendía, Maite; González-Tarancón, Ricardo; Romero-Sánchez, Naiara; Rello, Luis

    2017-07-26

    The direct bilirubin (D-Bil) assay on the AU Beckman Coulter instrumentation can be interfered by paraproteins, which may result in spurious D-Bil results. In a previous work, we took advantage of this fact to detect this interference, thus helping with the identification of patients with unsuspected monoclonal gammopathies. In this work, we investigate the possibility to detect interference based on the review of the photometric reactions, regardless of the D-Bil result. The D-Bil assay was carried out in a set of 2164 samples. It included a group of 164 samples with paraproteins (67 of which caused interference on the assay), as well as different groups of samples for which high absorbance background readings could also be expected (i.e. hemolyzed, lipemic, or icteric samples). Photometric reaction data were reviewed and receiver operating characteristics (ROC) curves were used to establish a cut-off for absorbance that best discriminates interference. The best cut-off was 0.0100 for the absorbance at the first photometric point of the complementary wavelength in the blank cuvette. Once the optimal cut-off for probable interference was selected, all samples analyzed in our laboratory that provided absorbance values above this cut-off were further investigated to try to discover paraproteins. During a period of 6 months, we detected 44 samples containing paraproteins, five of which belonged to patients with non-diagnosed monoclonal gammopathies. Review of the photometric reaction data permits the systematic detection of paraprotein interference on the D-Bil AU assay, even for samples for which reasonable results are obtained.

  18. Efficient source separation algorithms for acoustic fall detection using a microsoft kinect.

    PubMed

    Li, Yun; Ho, K C; Popescu, Mihail

    2014-03-01

    Falls have become a common health problem among older adults. In previous study, we proposed an acoustic fall detection system (acoustic FADE) that employed a microphone array and beamforming to provide automatic fall detection. However, the previous acoustic FADE had difficulties in detecting the fall signal in environments where interference comes from the fall direction, the number of interferences exceeds FADE's ability to handle or a fall is occluded. To address these issues, in this paper, we propose two blind source separation (BSS) methods for extracting the fall signal out of the interferences to improve the fall classification task. We first propose the single-channel BSS by using nonnegative matrix factorization (NMF) to automatically decompose the mixture into a linear combination of several basis components. Based on the distinct patterns of the bases of falls, we identify them efficiently and then construct the interference free fall signal. Next, we extend the single-channel BSS to the multichannel case through a joint NMF over all channels followed by a delay-and-sum beamformer for additional ambient noise reduction. In our experiments, we used the Microsoft Kinect to collect the acoustic data in real-home environments. The results show that in environments with high interference and background noise levels, the fall detection performance is significantly improved using the proposed BSS approaches.

  19. Pulse Tube Interference in Cryogenic Sensor Resonant Circuits - Final Paper

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lam, Tyler

    2015-08-27

    Transition edge sensors (TES) are extremely sensitive superconducting sensors, operating at 100 mK, which can be used to detect X-rays and Cosmic Microwave Background. The goal of our project is to design the electronics to read out an array of 10000 of these sensors by using microwave signals. However, we noticed the pulse tube used to maintain cryogenic temperatures caused interference in our readout. To determine the cause of the signal distortions, we used a detector with a 370 MHz sampling rate to collect and analyze sensor data. Although this data provided little information towards the nature of the noise,more » it was determined through a maintenance procedure than the 0.3 mm stainless steel wires were being vibrated due to acoustic waves, which distorted the signal. Replacing this wire appeared to cease the interference from the sensor data.« less

  20. Pulse Tube Interference in Cryogenic Sensors - Oral Presentation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lam, Tyler

    2015-08-24

    Transition edge sensors (TES) are extremely sensitive superconducting sensors, operating at 100 mK, which can be used to detect X-rays and Cosmic Microwave Background. The goal of our project is to design the electronics to read out an array of 10000 of these sensors by using microwave signals. However, we noticed the pulse tube used to maintain cryogenic temperatures caused interference in our readout. To determine the cause of the signal distortions, we used a detector with a 370 MHz sampling rate to collect and analyze sensor data. Although this data provided little information towards the nature of the noise,more » it was determined through a maintenance procedure than the 0.3 mm stainless steel wires were being vibrated due to acoustic waves, which distorted the signal. Replacing this wire appeared to cease the interference from the sensor data.« less

  1. Resonance--Continuum Interference in Light Higgs Boson Production at a Photon Collider

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dixon, Lance J.; Sofianatos, Yorgos; /SLAC /Stanford U., Phys. Dept.

    2009-01-06

    We study the effect of interference between the Standard Model Higgs boson resonance and the continuum background in the process {gamma}{gamma} {yields} H {yields} b{bar b} at a photon collider. Taking into account virtual gluon exchange between the final-state quarks, we calculate the leading corrections to the height of the resonance for the case of a light (m{sub H} < 160 GeV) Higgs boson. We find that the interference is destructive and around 0.1-0.2% of the peak height, depending on the mass of the Higgs and the scattering angle. This suppression is smaller by an order of magnitude than themore » anticipated experimental accuracy at a photon collider. However, the fractional suppression can be significantly larger if the Higgs coupling to b quarks is increased by physics beyond the Standard Model.« less

  2. Bi-dimensional empirical mode decomposition based fringe-like pattern suppression in polarization interference imaging spectrometer

    NASA Astrophysics Data System (ADS)

    Ren, Wenyi; Cao, Qizhi; Wu, Dan; Jiang, Jiangang; Yang, Guoan; Xie, Yingge; Wang, Guodong; Zhang, Sheqi

    2018-01-01

    Many observers using interference imaging spectrometer were plagued by the fringe-like pattern(FP) that occurs for optical wavelengths in red and near-infrared region. It brings us more difficulties in the data processing such as the spectrum calibration, information retrieval, and so on. An adaptive method based on the bi-dimensional empirical mode decomposition was developed to suppress the nonlinear FP in polarization interference imaging spectrometer. The FP and corrected interferogram were separated effectively. Meanwhile, the stripes introduced by CCD mosaic was suppressed. The nonlinear interferogram background removal and the spectrum distortion correction were implemented as well. It provides us an alternative method to adaptively suppress the nonlinear FP without prior experimental data and knowledge. This approach potentially is a powerful tool in the fields of Fourier transform spectroscopy, holographic imaging, optical measurement based on moire fringe, etc.

  3. Iconic Native Culture Cues Inhibit Second Language Production in a Non-immigrant Population: Evidence from Bengali-English Bilinguals.

    PubMed

    Roychoudhuri, Kesaban S; Prasad, Seema G; Mishra, Ramesh K

    2016-01-01

    We examined if iconic pictures belonging to one's native culture interfere with second language production in bilinguals in an object naming task. Bengali-English bilinguals named pictures in both L1 and L2 against iconic cultural images representing Bengali culture or neutral images. Participants named in both "Blocked" and "Mixed" language conditions. In both conditions, participants were significantly slower in naming in English when the background was an iconic Bengali culture picture than a neutral image. These data suggest that native language culture cues lead to activation of the L1 lexicon that competed against L2 words creating an interference. These results provide further support to earlier observations where such culture related interference has been observed in bilingual language production. We discuss the results in the context of cultural influence on the psycholinguistic processes in bilingual object naming.

  4. Age-Group Differences in Interference from Young and Older Emotional Faces.

    PubMed

    Ebner, Natalie C; Johnson, Marcia K

    2010-11-01

    Human attention is selective, focusing on some aspects of events at the expense of others. In particular, angry faces engage attention. Most studies have used pictures of young faces, even when comparing young and older age groups. Two experiments asked (1) whether task-irrelevant faces of young and older individuals with happy, angry, and neutral expressions disrupt performance on a face-unrelated task, (2) whether interference varies for faces of different ages and different facial expressions, and (3) whether young and older adults differ in this regard. Participants gave speeded responses on a number task while irrelevant faces appeared in the background. Both age groups were more distracted by own than other-age faces. In addition, young participants' responses were slower for angry than happy faces, whereas older participants' responses were slower for happy than angry faces. Factors underlying age-group differences in interference from emotional faces of different ages are discussed.

  5. Distribution of fixed beneficial mutations and the rate of adaptation in asexual populations

    PubMed Central

    Good, Benjamin H.; Rouzine, Igor M.; Balick, Daniel J.; Hallatschek, Oskar; Desai, Michael M.

    2012-01-01

    When large asexual populations adapt, competition between simultaneously segregating mutations slows the rate of adaptation and restricts the set of mutations that eventually fix. This phenomenon of interference arises from competition between mutations of different strengths as well as competition between mutations that arise on different fitness backgrounds. Previous work has explored each of these effects in isolation, but the way they combine to influence the dynamics of adaptation remains largely unknown. Here, we describe a theoretical model to treat both aspects of interference in large populations. We calculate the rate of adaptation and the distribution of fixed mutational effects accumulated by the population. We focus particular attention on the case when the effects of beneficial mutations are exponentially distributed, as well as on a more general class of exponential-like distributions. In both cases, we show that the rate of adaptation and the influence of genetic background on the fixation of new mutants is equivalent to an effective model with a single selection coefficient and rescaled mutation rate, and we explicitly calculate these effective parameters. We find that the effective selection coefficient exactly coincides with the most common fixed mutational effect. This equivalence leads to an intuitive picture of the relative importance of different types of interference effects, which can shift dramatically as a function of the population size, mutation rate, and the underlying distribution of fitness effects. PMID:22371564

  6. Integrable optical-fiber source of polarization-entangled photon pairs in the telecom band

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li Xiaoying; Liang Chuang; Fook Lee, Kim

    We demonstrate an optical-fiber-based source of polarization-entangled photon pairs with improved quality and efficiency, which has been integrated with off-the-shelf telecom components and is, therefore, well suited for quantum communication applications in the 1550-nm telecom band. Polarization entanglement is produced by simultaneously pumping a loop of standard dispersion-shifted fiber with two orthogonally polarized pump pulses, one propagating in the clockwise and the other in the counterclockwise direction. We characterize this source by investigating two-photon interference between the generated signal-idler photon pairs under various conditions. The experimental parameters are carefully optimized to maximize the generated photon-pair correlation and to minimize contaminationmore » of the entangled photon pairs from extraneously scattered background photons that are produced by the pump pulses for two reasons: (i) spontaneous Raman scattering causes uncorrelated photons to be emitted in the signal and idler bands and (ii) broadening of the pump-pulse spectrum due to self-phase modulation causes pump photons to leak into the signal and idler bands. We obtain two-photon interference with visibility >90% without subtracting counts caused by the background photons (only dark counts of the detectors are subtracted), when the mean photon number in the signal (idler) channel is about 0.02/pulse, while no interference is observed in direct detection of either the signal or idler photons.« less

  7. Protein and cell wall polysaccharide carbonyl determination by a neutral pH 2,4-dinitrophenylhydrazine-based photometric assay.

    PubMed

    Georgiou, Christos D; Zisimopoulos, Dimitrios; Argyropoulou, Vasiliki; Kalaitzopoulou, Electra; Salachas, George; Grune, Tilman

    2018-04-10

    A new 2,4-dinitrophenylhydrazine (DNPH)-based photometric assay is developed for the quantification of carbonyls in protein samples from any biological source by protein carbonyl-DNPH hydrazone formation at acidic pH in the presence of denaturing urea, and subsequent hydrazone solubilization in the presence of SDS and stabilization from acid hydrolysis at pH 7.0. At this neutral (ntr) pH, interfering unreacted DNPH is uncharged and its thus increased hydrophobicity permits its 100% effective removal from the solubilizate with ethyl acetate/hexane wash. The ntrDNPH assay is more reliable and sensitive than the standard (std) DNPH photometric assay because it eliminates its main limitations: (i) interfering unreacted DNPH (pKa 1.55) that is nonspecifically bound to the TCA (pKa 0.7)-protein pellet is not effectively removed after wash with EtOH: ethyl acetate because it is positively charged, (ii) acid (TCA-induced) hydrolysis of the protein carbonyl-DNPH hydrazone, (iii) sample protein concentration re-determination, (iv) loss of sample acid (TCA)-soluble proteins, (v) DNA interference, and (vi) requires high protein quantity samples (≥ 1 mg). Considering ntrDNPH assay's very low protein limit (1 µg), its cumulative and functional sensitivities are 2600- and 2000-fold higher than those of the stdDNPH assay, respectively. The present study elucidates the DNA interference mechanism on the stdDNPH assay, and also develops a standardized protocol for sample protein treatment and fractionation (into cytoplasmic/aqueous, membrane/lipid-bound, and histone/DNA-bound proteins; see Supplement section V) in order to ensure reproducible carbonyl determination on defined cell protein fractions, and to eliminate assay interference from protein samples containing (i) Cys sulfenic acid groups (via their neutralization with dithiothreitol), and (ii) DNA (via its removal by streptomycin sulfate precipitation). Lastly, the ntrDNPH assay determines carbonyl groups on cell wall polysaccharides, thus paving the way on studies to investigate cell walls acting as antioxidant defense in plants, fungi, bacteria and lichens. Copyright © 2018. Published by Elsevier B.V.

  8. Let Them Blow Bubbles.

    ERIC Educational Resources Information Center

    Korenic, Eileen

    1988-01-01

    Describes a series of activities and demonstrations involving the science of soap bubbles. Starts with a recipe for bubble solution and gives instructions for several activities on topics such as density, interference colors, optics, static electricity, and galaxy formation. Contains some background information to help explain some of the effects.…

  9. Direct Evidence of Acetaminophen Interference with Subcutaneous Glucose Sensing in Humans: A Pilot Study

    PubMed Central

    Basu, Ananda; Veettil, Sona; Dyer, Roy; Peyser, Thomas

    2016-01-01

    Abstract Background: Recent advances in accuracy and reliability of continuous glucose monitoring (CGM) devices have focused renewed interest on the use of such technology for therapeutic dosing of insulin without the need for independent confirmatory blood glucose meter measurements. An important issue that remains is the susceptibility of CGM devices to erroneous readings in the presence of common pharmacologic interferences. We report on a new method of assessing CGM sensor error to pharmacologic interferences using the example of oral administration of acetaminophen. Materials and Methods: We examined the responses of several different Food and Drug Administration–approved and commercially available CGM systems (Dexcom [San Diego, CA] Seven® Plus™, Medtronic Diabetes [Northridge, CA] Guardian®, and Dexcom G4® Platinum) to oral acetaminophen in 10 healthy volunteers without diabetes. Microdialysis catheters were placed in the abdominal subcutaneous tissue. Blood and microdialysate samples were collected periodically and analyzed for glucose and acetaminophen concentrations before and after oral ingestion of 1 g of acetaminophen. We compared the response of CGM sensors with the measured acetaminophen concentrations in the blood and interstitial fluid. Results: Although plasma glucose concentrations remained constant at approximately 90 mg/dL (approximately 5 mM) throughout the study, CGM glucose measurements varied between approximately 85 to 400 mg/dL (from approximately 5 to 22 mM) due to interference from the acetaminophen. The temporal profile of CGM interference followed acetaminophen concentrations measured in interstitial fluid (ISF). Conclusions: This is the first direct measurement of ISF concentrations of putative CGM interferences with simultaneous measurements of CGM performance in the presence of the interferences. The observed interference with glucose measurements in the tested CGM devices coincided temporally with appearance of acetaminophen in the ISF. The method applied here can be used to determine the susceptibility of current and future CGM systems to interference from acetaminophen or other exogenous pharmacologic agents. PMID:26784129

  10. Exploring Ramsey-coherent population trapping atomic clock realized with pulsed microwave modulated laser

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yang, Jing; Yun, Peter; Tian, Yuan

    2014-03-07

    A scheme for a Ramsey-coherent population trapping (CPT) atomic clock that eliminates the acousto-optic modulator (AOM) is proposed and experimentally studied. Driven by a periodically microwave modulated current, the vertical-cavity surface-emitting laser emits a continuous beam that switches between monochromatic and multichromatic modes. Ramsey-CPT interference has been studied with this mode-switching beam. In eliminating the AOM, which is used to generate pulsed laser in conventional Ramsey-CPT atomic clock, the physics package of the proposed scheme is virtually the same as that of a conventional compact CPT atomic clock, although the resource budget for the electronics will slightly increase as amore » microwave switch should be added. By evaluating and comparing experimentally recorded signals from the two Ramsey-CPT schemes, the short-term frequency stability of the proposed scheme was found to be 46% better than the scheme with AOM. The experimental results suggest that the implementation of a compact Ramsey-CPT atomic clock promises better frequency stability.« less

  11. Awareness Becomes Necessary Between Adaptive Pattern Coding of Open and Closed Curvatures

    PubMed Central

    Sweeny, Timothy D.; Grabowecky, Marcia; Suzuki, Satoru

    2012-01-01

    Visual pattern processing becomes increasingly complex along the ventral pathway, from the low-level coding of local orientation in the primary visual cortex to the high-level coding of face identity in temporal visual areas. Previous research using pattern aftereffects as a psychophysical tool to measure activation of adaptive feature coding has suggested that awareness is relatively unimportant for the coding of orientation, but awareness is crucial for the coding of face identity. We investigated where along the ventral visual pathway awareness becomes crucial for pattern coding. Monoptic masking, which interferes with neural spiking activity in low-level processing while preserving awareness of the adaptor, eliminated open-curvature aftereffects but preserved closed-curvature aftereffects. In contrast, dichoptic masking, which spares spiking activity in low-level processing while wiping out awareness, preserved open-curvature aftereffects but eliminated closed-curvature aftereffects. This double dissociation suggests that adaptive coding of open and closed curvatures straddles the divide between weakly and strongly awareness-dependent pattern coding. PMID:21690314

  12. Adaptive array antenna for satellite cellular and direct broadcast communications

    NASA Technical Reports Server (NTRS)

    Horton, Charles R.; Abend, Kenneth

    1993-01-01

    Adaptive phased-array antennas provide cost-effective implementation of large, light weight apertures with high directivity and precise beamshape control. Adaptive self-calibration allows for relaxation of all mechanical tolerances across the aperture and electrical component tolerances, providing high performance with a low-cost, lightweight array, even in the presence of large physical distortions. Beam-shape is programmable and adaptable to changes in technical and operational requirements. Adaptive digital beam-forming eliminates uplink contention by allowing a single electronically steerable antenna to service a large number of receivers with beams which adaptively focus on one source while eliminating interference from others. A large, adaptively calibrated and fully programmable aperture can also provide precise beam shape control for power-efficient direct broadcast from space. Advanced adaptive digital beamforming technologies are described for: (1) electronic compensation of aperture distortion, (2) multiple receiver adaptive space-time processing, and (3) downlink beam-shape control. Cost considerations for space-based array applications are also discussed.

  13. Matrix-elimination with steam distillation for determination of short-chain fatty acids in hypersaline waters from pre-salt layer by ion-exclusion chromatography.

    PubMed

    Ferreira, Fernanda N; Carneiro, Manuel C; Vaitsman, Delmo S; Pontes, Fernanda V M; Monteiro, Maria Inês C; Silva, Lílian Irene D da; Neto, Arnaldo Alcover

    2012-02-03

    A method for determination of formic, acetic, propionic and butyric acids in hypersaline waters by ion-exclusion chromatography (IEC), using steam distillation to eliminate matrix-interference, was developed. The steam distillation variables such as type of solution to collect the distillate, distillation time and volume of the 50% v/v H₂SO₄ solution were optimized. The effect of the addition of NaCl different concentrations to the calibration standards on the carboxylic acid recovery was also investigated. Detection limits of 0.2, 0.5, 0.3 and 1.5 mg L⁻¹ were obtained for formic, acetic, propionic and butyric acids, respectively. Produced waters from petroleum reservoirs in the Brazilian pre-salt layer containing about 19% m/v of NaCl were analyzed. Good recoveries (99-108%) were obtained for all acids in spiked produced water samples. Copyright © 2011 Elsevier B.V. All rights reserved.

  14. Large-mirror testing facility at the National Optical Astronomy Observatories.

    NASA Astrophysics Data System (ADS)

    Barr, L. D.; Coudé du Foresto, V.; Fox, J.; Poczulp, G. A.; Richardson, J.; Roddier, C.; Roddier, F.

    1991-09-01

    A method for testing the surfaces of large mirrors has been developed to be used even when conditions of vibration and thermal turbulence in the light path cannot be eliminated. The full aperture of the mirror under test is examined by means of a scatterplate interferometer that has the property of being a quasi-common-path method, although any means for obtaining interference fringes will do. The method uses a remotely operated CCD camera system to record the fringe pattern from the workpiece. The typical test is done with a camera exposure of about a millisecond to "freeze" the fringe pattern on the detector. Averaging up to 10 separate exposures effectively eliminates the turbulence effects. The method described provides the optician with complete numerical information and visual plots for the surface under test and the diffracted image the method will produce, all within a few minutes, to an accuracy of 0.01 μm measured peak-to-valley.

  15. Sector-Based Detection for Hands-Free Speech Enhancement in Cars

    NASA Astrophysics Data System (ADS)

    Lathoud, Guillaume; Bourgeois, Julien; Freudenberger, Jürgen

    2006-12-01

    Adaptation control of beamforming interference cancellation techniques is investigated for in-car speech acquisition. Two efficient adaptation control methods are proposed that avoid target cancellation. The "implicit" method varies the step-size continuously, based on the filtered output signal. The "explicit" method decides in a binary manner whether to adapt or not, based on a novel estimate of target and interference energies. It estimates the average delay-sum power within a volume of space, for the same cost as the classical delay-sum. Experiments on real in-car data validate both methods, including a case with[InlineEquation not available: see fulltext.] km/h background road noise.

  16. Energetic Charged Particle Emission from Hydrogen-Loaded pd and ti Cathodes and its Enhancement by He-4 Implantation

    NASA Astrophysics Data System (ADS)

    Lipson, A. G.; Miley, G. H.; Lipson, A. G.; Lyakhov, B. F.; Roussetski, A. S.

    2006-02-01

    In this paper, we demonstrate reproducible emissions of energetic alphas and protons appearing in an energy range where both cosmic ray interference and possible alpha emissions from contamination (e.g., radon) is assumed to be negligible. We also show that He4 doping of Pd and Ti cathodes leads to a significant enhancement of the energetic charged particles emission (ECPE). This measurement of the emissions of energetic (MeV) particles, in a region of low background interference plus their enhancement by He4 doping provides very strong support for the existence of LENR processes in the crystalline lattice of deuterated metals.

  17. A Novel Fabry-Perot Cavity Fiber Sensor

    NASA Astrophysics Data System (ADS)

    Lin, Chun; Huang, Yuan Qing; Lei, Wang; Ye, Xiao Juan

    Fabry-Perot (F-P) cavity fiber sensors are often used in acceleration, vibration and pressure measurement. When the structure of sensors are similar, there are the same disadvantages exist. A novel design of Fabry-Perot (F-P) cavity fiber sensor is described in this paper, which is composed by a non-coating end-face and a holophote. Triple beams interference is formed in the sensor and shows higher sensitivity. In order to demodulate interference signal in great background noise, two photodiodes are connected in series to form short circuit current which delimits the common mode signal. Experimental results are described for the sensor signal responding to the vibration excited by PZT.^p

  18. Modulated FT- Raman Fiber-Optic Spectroscopy: A technique for Remotely Monitoring High-Temperature Reactions in Real-Time

    NASA Technical Reports Server (NTRS)

    Cooper, John B.; Wise, Kent L.; Jensen, Brian J.

    1997-01-01

    A modification to a commercial FT-Raman spectrometer is presented for the elimination of thermal backgrounds in FT-Raman spectra. The modification involves the use of a mechanical chopper to modulate the CW laser, remote collection of the signal via fiber optics, and connection of a dual-phase digital signal processor lock-in amplifier between the detector and the spectrometer's collection electronics to demodulate and filter the optical signals. The resulting modulated FT-Raman fiber-optic spectrometer is capable of completely eliminating thermal backgrounds at temperatures exceeding 370 C. In addition, the signal/noise of generated Raman spectra is greater than for spectra collected with the conventional FT-Raman under identical conditions and incident laser power. This is true for both room-temperature and hot samples. The method allows collection of data using preexisting spectrometer software. The total cost of the modification (excluding fiber optics) is approximately $3000 and requires less than 2 h to implement. This is the first report of Fr-Raman spectra collected at temperatures in excess of 300 C in the absence of thermal backgrounds.

  19. Spectral interferences in the determination of rhenium in molybdenum and copper concentrates by inductively coupled plasma optical emission spectrometry (ICP-OES)

    NASA Astrophysics Data System (ADS)

    Karadjov, Metody; Velitchkova, Nikolaya; Veleva, Olga; Velichkov, Serafim; Markov, Pavel; Daskalova, Nonka

    2016-05-01

    This paper deals with spectral interferences of complex matrix containing Mo, Al, Ti, Fe, Mg, Ca and Cu in the determination of rhenium in molybdenum and copper concentrates by inductively coupled plasma optical emission spectrometry (ICP-OES). By radial viewing 40.68 MHz ICP equipped with a high resolution spectrometer (spectral bandwidth = 5 pm) the hyperfine structure (HFS) of the most prominent lines of rhenium (Re II 197.248 nm, Re II 221.426 nm and Re II 227.525 nm) was registered. The HFS components under high resolution conditions were used as separate prominent line in order to circumvent spectral interferences. The Q-concept was applied for quantification of spectral interferences. The quantitative databases for the type and the magnitude of the spectral interferences in the presence of above mentioned matrix constituents were obtained by using a radial viewing 40.68 MHz ICP with high resolution and an axial viewing 27.12 MHz ICP with middle resolution. The data for the both ICP-OES systems were collected chiefly with a view to spectrochemical analysis for comparing the magnitude of line and wing (background) spectral interference and the true detection limits with spectroscopic apparatus with different spectral resolution. The sample pretreatment methods by sintering with magnesium oxide and oxidizing agents as well as a microwave acid digestion were applied. The feasibility, accuracy and precision of the analytical results were experimentally demonstrated by certified reference materials.

  20. Laser-induced volatilization and ionization of microparticles

    NASA Technical Reports Server (NTRS)

    Sinha, M. P.

    1984-01-01

    A method for the laser vaporization and ionization of individual micron-size particles is presented whereby a particle is ionized by a laser pulse while in flight in the beam. Ionization in the beam offers a real-time analytical capability and eliminates any possible substrate-sample interferences during an analysis. An experimental arrangement using a high-energy Nd-YAG laser is described, and results are presented for ions generated from potassium biphthalate particles (1.96 micron in diameter). The method proposed here is useful for the chemical analysis of aerosol particles by mass spectrometry and for other spectroscopic and chemical kinetic studies.

  1. Astronaut George Nelson working on Comet Halley Active monitoring program

    NASA Image and Video Library

    1986-01-14

    61C-05-026 (14 Jan. 1986) --- Astronaut George D. Nelson smiles for a fellow crew man's 35mm camera exposure while participating in the Comet Halley active monitoring program (CHAMP). Camera equipment and a protective shroud used to eliminate all cabin light interference surround the mission specialist. This is the first of three 1986 missions which are scheduled to monitor the rare visit by the comet. The principal investigators for CHAMP are S. Alan Stern of the Laboratory for Atmospheric and Space Physics at the University of Colorado; and Dr. Stephen Mende of Lockheed Palo Alto Research Laboratory.

  2. Design of a Pressure Sensor Based on Optical Fiber Bragg Grating Lateral Deformation

    PubMed Central

    Urban, Frantisek; Kadlec, Jaroslav; Vlach, Radek; Kuchta, Radek

    2010-01-01

    This paper describes steps involved in the design and realization of a new type of pressure sensor based on the optical fiber Bragg grating. A traditional pressure sensor has very limited usage in heavy industrial environments, particularly in explosive or electromagnetically noisy environments. Utilization of optics in these environments eliminates all surrounding influences. An initial motivation for our development was the research, experimental validation, and realization of a complex smart pressure sensor based on the optical principle. The main benefit of this solution consists of increasing sensitivity, resistance to electromagnetic interference, dimensions, and potential increased accuracy. PMID:22163521

  3. Transport characteristics of μ-SQUIDs for probing magnetism

    NASA Astrophysics Data System (ADS)

    Biswas, Sourav; Paul, Sagar; Parashari, Harsh; Winkelmann, Clemens B.; Courtois, Hervé; Gupta, Anjan K.

    2018-04-01

    We study the transport properties of niobium (Nb) based micron sized superconducting quantum interference devices (μ-SQUID), which are designed to eliminate thermal hysteresis down to 1.3 K. Current-voltage characteristics are non-hysterestic at the lowest temperature. Large voltage oscillations with magnetic field are observed for a wide range of bias currents with good flux sensitivity and reduced flux noise. However, devices with fins and devices on sapphire substrate show hysteresis for wide range of bath temperature. We have also been able to see the sign of magnetic response from a single micron size ferromagnetic permalloy ellipse using the μ-SQUID.

  4. Cutoff-mesa isolated rib optical waveguide for III-V heterostructure photonic integrated circuits

    DOEpatents

    Vawter, Gregory A.; Smith, Robert E.

    1998-01-01

    A cutoff mesa rib waveguide provides single-mode performance regardless of any deep etches that might be used for electrical isolation between integrated electrooptic devices. Utilizing a principle of a cutoff slab waveguide with an asymmetrical refractive index profile, single mode operation is achievable with a wide range of rib widths and does not require demanding etch depth tolerances. This new waveguide design eliminates reflection effects, or self-interference, commonly seen when conventional rib waveguides are combined with deep isolation etches and thereby reduces high order mode propagation and crosstalk compared to the conventional rib waveguides.

  5. Cutoff-mesa isolated rib optical waveguide for III-V heterostructure photonic integrated circuits

    DOEpatents

    Vawter, G.A.; Smith, R.E.

    1998-04-28

    A cutoff mesa rib waveguide provides single-mode performance regardless of any deep etches that might be used for electrical isolation between integrated electrooptic devices. Utilizing a principle of a cutoff slab waveguide with an asymmetrical refractive index profile, single mode operation is achievable with a wide range of rib widths and does not require demanding etch depth tolerances. This new waveguide design eliminates reflection effects, or self-interference, commonly seen when conventional rib waveguides are combined with deep isolation etches and thereby reduces high order mode propagation and crosstalk compared to the conventional rib waveguides. 7 figs.

  6. Method for shallow junction formation

    DOEpatents

    Weiner, K.H.

    1996-10-29

    A doping sequence is disclosed that reduces the cost and complexity of forming source/drain regions in complementary metal oxide silicon (CMOS) integrated circuit technologies. The process combines the use of patterned excimer laser annealing, dopant-saturated spin-on glass, silicide contact structures and interference effects creates by thin dielectric layers to produce source and drain junctions that are ultrashallow in depth but exhibit low sheet and contact resistance. The process utilizes no photolithography and can be achieved without the use of expensive vacuum equipment. The process margins are wide, and yield loss due to contact of the ultrashallow dopants is eliminated. 8 figs.

  7. Method for shallow junction formation

    DOEpatents

    Weiner, Kurt H.

    1996-01-01

    A doping sequence that reduces the cost and complexity of forming source/drain regions in complementary metal oxide silicon (CMOS) integrated circuit technologies. The process combines the use of patterned excimer laser annealing, dopant-saturated spin-on glass, silicide contact structures and interference effects creates by thin dielectric layers to produce source and drain junctions that are ultrashallow in depth but exhibit low sheet and contact resistance. The process utilizes no photolithography and can be achieved without the use of expensive vacuum equipment. The process margins are wide, and yield loss due to contact of the ultrashallow dopants is eliminated.

  8. Detection of elemental mercury by multimode diode laser correlation spectroscopy.

    PubMed

    Lou, Xiutao; Somesfalean, Gabriel; Svanberg, Sune; Zhang, Zhiguo; Wu, Shaohua

    2012-02-27

    We demonstrate a method for elemental mercury detection based on correlation spectroscopy employing UV laser radiation generated by sum-frequency mixing of two visible multimode diode lasers. Resonance matching of the multimode UV laser is achieved in a wide wavelength range and with good tolerance for various operating conditions. Large mode-hops provide an off-resonance baseline, eliminating interferences from other gas species with broadband absorption. A sensitivity of 1 μg/m3 is obtained for a 1-m path length and 30-s integration time. The performance of the system shows promise for mercury monitoring in industrial applications.

  9. The SUMO Pathway Is Developmentally Regulated and Required for Programmed DNA Elimination in Paramecium tetraurelia† ‡

    PubMed Central

    Matsuda, Atsushi; Forney, James D.

    2006-01-01

    Extensive genome-wide remodeling occurs during the formation of the somatic macronuclei from the germ line micronuclei in ciliated protozoa. This process is limited to sexual reproduction and includes DNA amplification, chromosome fragmentation, and the elimination of internal segments of DNA. Our efforts to define the pathways regulating these events revealed a gene encoding a homologue of ubiquitin activating enzyme 2 (UBA2) that is upregulated at the onset of macronuclear development in Paramecium tetraurelia. Uba2 enzymes are known to activate the protein called small ubiquitin-related modifier (SUMO) that is covalently attached to target proteins. Consistent with this relationship, Northern analysis showed increased abundance of SUMO transcripts during sexual reproduction in Paramecium. RNA interference (RNAi) against UBA2 or SUMO during vegetative growth had little effect on cell survival or fission rates. In contrast, RNAi of mating cells resulted in failure to form a functional macronucleus. Despite normal amplification of the genome, excision of internal eliminated sequences was completely blocked. Additional experiments showed that the homologous UBA2 and SUMO genes in Tetrahymena thermophila are also upregulated during conjugation. These results provide evidence for the developmental regulation of the SUMO pathway in ciliates and suggest a key role for the pathway in controlling genome remodeling. PMID:16682458

  10. Elimination of endogenous aberrant kappa chain transcripts from sp2/0-derived hybridoma cells by specific ribozyme cleavage: utility in genetic therapy of HIV-1 infections.

    PubMed Central

    Duan, L; Pomerantz, R J

    1994-01-01

    The pooled degenerate-primer polymerase chain reaction (PCR) technology is now widely used in the amplification and cloning of murine hybridoma-specific immunoglobulin gene cDNAs. The design of primers is mainly based on the highly conserved 5' terminus of immunoglobulin gene variable regions and the constant region in the 3' terminus. Of note, most murine hybridoma cell lines are derived from the Sp2/0 cell line, which is demonstrated to express endogenous aberrant kappa chains (abV kappa). This high-level endogenous abV kappa mixes with specific kappa chains in the hybridomas and interferes with the efficiency of the reverse transcriptase (RT)-PCR cloning strategy. In this report, during the cloning of murine anti-human immunodeficiency virus type I (HIV-1) hybridoma immunoglobulin cDNAs, a specific primer-PCR screening system was developed, based on the abV kappa complementarity-defining region (CDR), to eliminate abV kappa-carrying plasmids. Furthermore, an abV kappa sequence-specific derived ribozyme was developed and packaged in a retroviral expression vector system. This abV kappa ribozyme can be transduced into different murine hybridomas, and expressed intracellularly to potently eliminate endogenous abV kappa RNA. Images PMID:7816635

  11. Discourse on malaria elimination: where do forcibly displaced persons fit in these discussions?

    PubMed Central

    2013-01-01

    Background Individuals forcibly displaced are some of the poorest people in the world, living in areas where infrastructure and services are at a bare minimum. Out of a total of 10,549,686 refugees protected and assisted by the United Nations High Commissioner for Refugees globally, 6,917,496 (65.6%) live in areas where malaria is transmitted. Historically, national malaria control programmes have excluded displaced populations. Results The current discourse on malaria elimination rarely includes discussion of forcibly displaced persons who reside within malaria-eliminating countries. Of the 100 malaria-endemic countries, 64 are controlling malaria and 36 are in some stage of elimination. Of these, 30 malaria-controlling countries and 13 countries in some phase of elimination host displaced populations of ≥50,000, even though 13 of the 36 (36.1%) malaria-elimination countries host displaced populations of ≥50,000 people. Discussion Now is the time for the malaria community to incorporate forcibly displaced populations residing within malarious areas into malaria control activities. Beneficiaries, whether they are internally displaced persons or refugees, should be viewed as partners in the delivery of malaria interventions and not simply as recipients. Conclusion Until equitable and sustainable malaria control includes everyone residing in an endemic area, the goal of malaria elimination will not be met. PMID:23575209

  12. Thermodynamic measurements in a high pressure hydrogen-oxygen flame using Raman scattering from a broadband excimer laser

    NASA Technical Reports Server (NTRS)

    Hartfield, Roy, Jr.

    1996-01-01

    Raman scattering is an inelastic molecular scattering process in which incident radiation is reemitted at a fixed change in frequency. Raman spectroscopy can be used to measure the number density and temperature of the irradiated species. The strength of the Raman signal is inversely proportional to the wavelength raised to the fourth power. Consequently, high signal to noise ratios are obtained by using ultraviolet (UV) excitation sources. Using UV sources for Raman Spectroscopy in flames is complicated by the fact that some of the primary constituents in hydrogen-oxygen combustion absorb and reemit light in the UV and these fluorescence processes interfere with the Raman signals. This problem has been handled in atmospheric pressure flames in some instances by using a narrowband tunable excimer laser as a source. This allows for detuning from absorption transitions and the elimination of interfering fluorescence signals at the Raman wavelengths. This approach works well in the atmospheric pressure flame; however, it has two important disadvantages. First, injection-locked narrowband tunable excimer lasers are very expensive. More importantly, however, is the fact that at the high pressures characteristic of rocket engine combustion chambers, the absorption transitions are broadened making it difficult to tune to a spectral location at which substantial absorption would not occur. The approach taken in this work is to separate the Raman signal from the fluorescence background by taking advantage of the fact that Raman signal has nonisotropic polarization characteristics while the fluorescence signals are unpolarized. Specifically, for scattering at right angles to the excitation beam path, the Raman signal is completely polarized. The Raman signal is separated from the fluorescence background by collecting both horizontally and vertically polarized signals separately. One of the polarizations has both the Raman signal and the fluorescence background while the other has only the fluorescence signal. The Raman scatter is the difference between the signals. By choosing an appropriate optical setup, both signals can be obtained simultaneously with the same monochromator; hence, time resolved measurements are possible using this approach.

  13. Comparison of UAV and WorldView-2 imagery for mapping leaf area index of mangrove forest

    NASA Astrophysics Data System (ADS)

    Tian, Jinyan; Wang, Le; Li, Xiaojuan; Gong, Huili; Shi, Chen; Zhong, Ruofei; Liu, Xiaomeng

    2017-09-01

    Unmanned Aerial Vehicle (UAV) remote sensing has opened the door to new sources of data to effectively characterize vegetation metrics at very high spatial resolution and at flexible revisit frequencies. Successful estimation of the leaf area index (LAI) in precision agriculture with a UAV image has been reported in several studies. However, in most forests, the challenges associated with the interference from a complex background and a variety of vegetation species have hindered research using UAV images. To the best of our knowledge, very few studies have mapped the forest LAI with a UAV image. In addition, the drawbacks and advantages of estimating the forest LAI with UAV and satellite images at high spatial resolution remain a knowledge gap in existing literature. Therefore, this paper aims to map LAI in a mangrove forest with a complex background and a variety of vegetation species using a UAV image and compare it with a WorldView-2 image (WV2). In this study, three representative NDVIs, average NDVI (AvNDVI), vegetated specific NDVI (VsNDVI), and scaled NDVI (ScNDVI), were acquired with UAV and WV2 to predict the plot level (10 × 10 m) LAI. The results showed that AvNDVI achieved the highest accuracy for WV2 (R2 = 0.778, RMSE = 0.424), whereas ScNDVI obtained the optimal accuracy for UAV (R2 = 0.817, RMSE = 0.423). In addition, an overall comparison results of the WV2 and UAV derived LAIs indicated that UAV obtained a better accuracy than WV2 in the plots that were covered with homogeneous mangrove species or in the low LAI plots, which was because UAV can effectively eliminate the influence from the background and the vegetation species owing to its high spatial resolution. However, WV2 obtained a slightly higher accuracy than UAV in the plots covered with a variety of mangrove species, which was because the UAV sensor provides a negative spectral response function(SRF) than WV2 in terms of the mangrove LAI estimation.

  14. Synthesis and study of the roadside vegetation establishment process.

    DOT National Transportation Integrated Search

    2011-05-01

    The Texas Pollutant Discharge Elimination System (TPDES), which is administered and enforced by the : Texas Commission on Environmental Quality (TCEQ), requires perennial vegetation to 70 percent of native : or adjacent background vegetation before a...

  15. The role of figure-ground segregation in change blindness.

    PubMed

    Landman, Rogier; Spekreijse, Henk; Lamme, Victor A F

    2004-04-01

    Partial report methods have shown that a large-capacity representation exists for a few hundred milliseconds after a picture has disappeared. However, change blindness studies indicate that very limited information remains available when a changed version of the image is presented subsequently. What happens to the large-capacity representation? New input after the first image may interfere, but this is likely to depend on the characteristics of the new input. In our first experiment, we show that a display containing homogeneous image elements between changing images does not render the large-capacity representation unavailable. Interference occurs when these new elements define objects. On that basis we introduce a new method to produce change blindness: The second experiment shows that change blindness can be induced by redefining figure and background, without an interval between the displays. The local features (line segments) that defined figures and background were swapped, while the contours of the figures remained where they were. Normally, changes are easily detected when there is no interval. However, our paradigm results in massive change blindness. We propose that in a change blindness experiment, there is a large-capacity representation of the original image when it is followed by a homogeneous interval display, but that change blindness occurs whenever the changed image forces resegregation of figures from the background.

  16. A perforated diamond anvil cell for high-energy x-ray diffraction of liquids and amorphous solids at high pressure.

    PubMed

    Soignard, Emmanuel; Benmore, Chris J; Yarger, Jeffery L

    2010-03-01

    Diamond anvil cells (DACs) are widely used for the study of materials at high pressure. The typical diamonds used are between 1 and 3 mm thick, while the sample contained within the opposing diamonds is often just a few microns in thickness. Hence, any absorbance or scattering from diamond can cause a significant background or interference when probing a sample in a DAC. By perforating the diamond to within 50-100 microm of the sample, the amount of diamond and the resulting background or interference can be dramatically reduced. The DAC presented in this article is designed to study amorphous materials at high pressure using high-energy x-ray scattering (>60 keV) using laser-perforated diamonds. A small diameter perforation maintains structural integrity and has allowed us to reach pressures >50 GPa, while dramatically decreasing the intensity of the x-ray diffraction background (primarily Compton scattering) when compared to studies using solid diamonds. This cell design allows us for the first time measurement of x-ray scattering from light (low Z) amorphous materials. Here, we present data for two examples using the described DAC with one and two perforated diamond geometries for the high-pressure structural studies of SiO(2) glass and B(2)O(3) glass.

  17. Probing the Higgs Couplings to Photons in h→4l at the LHC

    DOE PAGES

    Chen, Yi; Harnik, Roni; Vega-Morales, Roberto

    2014-11-01

    We explore the sensitivity of the Higgs decay to four leptons, the so-called golden channel, to higher dimensional loop-induced couplings of the Higgs boson tomore » $ZZ$, $$Z\\gamma$$, and $$\\gamma\\gamma$$, allowing for general CP mixtures. The larger standard model tree level coupling $$hZ^\\mu Z_\\mu$$ is the dominant "background" for the loop induced couplings. However this large background interferes with the smaller loop induced couplings, enhancing the sensitivity. We perform a maximum likelihood analysis based on analytic expressions of the fully differential decay width for $$h\\to 4\\ell$$ ($$4\\ell \\equiv 2e2\\mu, 4e, 4\\mu$$) including all interference effects. We find that the spectral shapes induced by Higgs couplings to photons are particularly different than the $$hZ^\\mu Z_\\mu$$ background leading to enhanced sensitivity to these couplings. We show that even if the $$h\\to\\gamma\\gamma$$ and $$h\\to 4\\ell$$ rates agree with that predicted by the Standard Model, the golden channel has the potential to probe both the CP nature as well as the overall sign of the Higgs coupling to photons well before the end of high-luminosity LHC running ($$\\sim$$3 ab$$^{-1}$$).« less

  18. DETERMINATION OF PERCHLORATE AT PARTS-PER-BILLION LEVELS IN PLANTS BY ION CHROMATOGRAPHY

    EPA Science Inventory

    A method for the analysis of perchlorate in plants was developed, based on dry weight, and applied to the analysis of plant organs, foodstuffs, and plant products. The method reduced greatly the ionic interferences in water extracts of plant materials. The high background conduct...

  19. Measurement of Infrasound from the Marine Environment

    DTIC Science & Technology

    2015-09-01

    ocean heave, which are due to the change in the background atmospheric pressure as the sensor moves up and down. An external inertial measurement unit ... inertial measurement unit (IMU) was used to estimate the heave, and was highly correlated with the pressure interference signal. Mission area... MEASUREMENT UNIT ..................................................... 13 ADAPTIVE NOISE CANCELATION

  20. Wavelength modulated surface enhanced (resonance) Raman scattering for background-free detection.

    PubMed

    Praveen, Bavishna B; Steuwe, Christian; Mazilu, Michael; Dholakia, Kishan; Mahajan, Sumeet

    2013-05-21

    Spectra in surface-enhanced Raman scattering (SERS) are always accompanied by a continuum emission called the 'background' which complicates analysis and is especially problematic for quantification and automation. Here, we implement a wavelength modulation technique to eliminate the background in SERS and its resonant version, surface-enhanced resonance Raman scattering (SERRS). This is demonstrated on various nanostructured substrates used for SER(R)S. An enhancement in the signal to noise ratio for the Raman bands of the probe molecules is also observed. This technique helps to improve the analytical ability of SERS by alleviating the problem due to the accompanying background and thus making observations substrate independent.

  1. Tripolar-cuff deviation from ideal model: assessment by bioelectric field simulations and saline-bath experiments.

    PubMed

    Triantis, Iasonas F; Demosthenous, Andreas

    2008-06-01

    Ideally, interference in neural measurements due to signals from nearby muscles can be completely eliminated with the use of tripolar cuffs, in combination with appropriate amplifier configurations, such as the quasi-tripole (QT) and the true-tripole (TT). The operation of these amplifiers, is based on the theoretical property of the nerve cuff to produce a linear relationship of potential versus distance along its length, internally, when external potentials appear between its ends. Thus, in principle, electroneurogram (ENG) recordings from an ideal tripolar cuff would be free from electromyogram (EMG) interference generated by nearby muscles. However, in practice the cuff exhibits non-ideal behaviour leading to "cuff imbalance". The main focus of this paper is to investigate the causes of cuff imbalance, to demonstrate that it should be incorporated as a main parameter in the theoretical ENG-recording cuff electrode model. In addition to cuff asymmetry and tissue growth, the proximity of the interference source to the cuff is shown to result in cuff imbalance. The influence of proximity imbalance on the performance of the QT and TT amplifiers is also considered. Proximity imbalance is studied using bioelectric field simulations and saline-bath experiments. Variation is observed with both distance (40 mm and 70 mm was examined) and orientation (0-180 degrees), with the latter causing a more severe effect especially when the source dipole and the cuff are vertical to each other. The simulations and measurements are in close agreement. Tissue growth imbalance and asymmetry imbalance are also investigated in vitro. Finally, the signal-to-interference ratio (SIR; ENG/EMG) of the QT and TT amplifiers is examined in the presence of cuff imbalance. It is shown that proximity imbalance results in their SIR to peak only at certain cuff orientation values. This important finding offers an insight as to why in practice ENG recordings using these amplifiers have been widely reported to be degraded by EMG interference.

  2. Elimination of residual amplitude modulation in tunable diode laser wavelength modulation spectroscopy using an optical fiber delay line.

    PubMed

    Chakraborty, Arup Lal; Ruxton, Keith; Johnstone, Walter; Lengden, Michael; Duffin, Kevin

    2009-06-08

    A new fiber-optic technique to eliminate residual amplitude modulation in tunable diode laser wavelength modulation spectroscopy is presented. The modulated laser output is split to pass in parallel through the gas measurement cell and an optical fiber delay line, with the modulation frequency / delay chosen to introduce a relative phase shift of pi between them. The two signals are balanced using a variable attenuator and recombined through a fiber coupler. In the absence of gas, the direct laser intensity modulation cancels, thereby eliminating the high background. The presence of gas induces a concentration-dependent imbalance at the coupler's output from which the absolute absorption profile is directly recovered with high accuracy using 1f detection.

  3. Nonuniform distribution of phase noise in distributed acoustic sensing based on phase-sensitive OTDR

    NASA Astrophysics Data System (ADS)

    Yu, Zhijie; Lu, Yang; Meng, Zhou

    2017-10-01

    A phase-sensitive optical time-domain reflectometry (∅-OTDR) implements distributed acoustic sensing (DAS) due to its ability for high sensitivity vibration measurement. Phase information of acoustic vibration events can be acquired by interrogation of the vibration-induced phase change between coherent Rayleigh scattering light from two points of the sensing fiber. And DAS can be realized when applying phase generated carrier (PGC) algorithm to the whole sensing fiber while the sensing fiber is transformed into a series of virtual sensing channels. Minimum detectable vibration of a ∅-OTDR is limited by phase noise level. In this paper, nonuniform distribution of phase noise of virtual sensing channels in a ∅-OTDR is investigated theoretically and experimentally. Correspondence between the intensity of Rayleigh scattering light and interference fading as well as polarization fading is analyzed considering inner interference of coherent Rayleigh light scattered from a multitude of scatters within pulse duration, and intensity noise related to the intensity of Rayleigh scattering light can be converted to phase noise while measuring vibration-induced phase change. Experiments are performed and the results confirm the predictions of the theoretical analysis. This study is essential for acquiring insight into nonuniformity of phase noise in DAS based on a ∅-OTDR, and would put forward some feasible methods to eliminate the effect of interference fading and polarization fading and optimize the minimum detectable vibration of a ∅-OTDR.

  4. Differential effect of blood collection tubes on total free fatty acids (FFA) and total triiodothyronine (TT3) concentration: a model for studying interference from tube constituents.

    PubMed

    Bowen, Raffick A R; Vu, Chi; Remaley, Alan T; Hortin, Glen L; Csako, Gyorgy

    2007-03-01

    Besides total triiodothyronine (TT3), total free fatty acids (FFA) concentrations were higher with serum separator tube (SST) than Vacuette tubes. The effects of surfactant, rubber stopper, and separator gel from various tubes were investigated on FFA, beta-hydroxybutyrate (beta-HB), and TT3 with 8 different tube types in blood specimens of apparently healthy volunteers. Compared to Vacuette tubes, serum FFA and TT3 concentrations were significantly higher in SST than glass tubes. Reformulated SST eliminated the increase in TT3 but not FFA. No significant difference was observed for beta-HB concentration among tube types. Surfactant and rubber stoppers from the different tube types significantly increased TT3 but not FFA and beta-HB concentrations. Agitation of whole blood but not serum or plasma specimens with separator gel from SST, reformulated SST and plasma preparation tube (PPT) tubes compared to Vacuette tubes gave higher FFA but not beta-HB levels. Unidentified component(s) from the separator gel in SST, reformulated SST and PPT tubes cause falsely high FFA concentration. In contrast to TT3, falsely high FFA results require exposure of whole blood and not serum to tube constituent(s). The approach employed here may serve as a model for assessing interference(s) from tube constituent(s).

  5. Understanding decimal proportions: discrete representations, parallel access, and privileged processing of zero.

    PubMed

    Varma, Sashank; Karl, Stacy R

    2013-05-01

    Much of the research on mathematical cognition has focused on the numbers 1, 2, 3, 4, 5, 6, 7, 8, and 9, with considerably less attention paid to more abstract number classes. The current research investigated how people understand decimal proportions--rational numbers between 0 and 1 expressed in the place-value symbol system. The results demonstrate that proportions are represented as discrete structures and processed in parallel. There was a semantic interference effect: When understanding a proportion expression (e.g., "0.29"), both the correct proportion referent (e.g., 0.29) and the incorrect natural number referent (e.g., 29) corresponding to the visually similar natural number expression (e.g., "29") are accessed in parallel, and when these referents lead to conflicting judgments, performance slows. There was also a syntactic interference effect, generalizing the unit-decade compatibility effect for natural numbers: When comparing two proportions, their tenths and hundredths components are processed in parallel, and when the different components lead to conflicting judgments, performance slows. The results also reveal that zero decimals--proportions ending in zero--serve multiple cognitive functions, including eliminating semantic interference and speeding processing. The current research also extends the distance, semantic congruence, and SNARC effects from natural numbers to decimal proportions. These findings inform how people understand the place-value symbol system, and the mental implementation of mathematical symbol systems more generally. Copyright © 2013 Elsevier Inc. All rights reserved.

  6. Validity threats: overcoming interference with proposed interpretations of assessment data.

    PubMed

    Downing, Steven M; Haladyna, Thomas M

    2004-03-01

    Factors that interfere with the ability to interpret assessment scores or ratings in the proposed manner threaten validity. To be interpreted in a meaningful manner, all assessments in medical education require sound, scientific evidence of validity. The purpose of this essay is to discuss 2 major threats to validity: construct under-representation (CU) and construct-irrelevant variance (CIV). Examples of each type of threat for written, performance and clinical performance examinations are provided. The CU threat to validity refers to undersampling the content domain. Using too few items, cases or clinical performance observations to adequately generalise to the domain represents CU. Variables that systematically (rather than randomly) interfere with the ability to meaningfully interpret scores or ratings represent CIV. Issues such as flawed test items written at inappropriate reading levels or statistically biased questions represent CIV in written tests. For performance examinations, such as standardised patient examinations, flawed cases or cases that are too difficult for student ability contribute CIV to the assessment. For clinical performance data, systematic rater error, such as halo or central tendency error, represents CIV. The term face validity is rejected as representative of any type of legitimate validity evidence, although the fact that the appearance of the assessment may be an important characteristic other than validity is acknowledged. There are multiple threats to validity in all types of assessment in medical education. Methods to eliminate or control validity threats are suggested.

  7. The Whorfian time warp: Representing duration through the language hourglass.

    PubMed

    Bylund, Emanuel; Athanasopoulos, Panos

    2017-07-01

    How do humans construct their mental representations of the passage of time? The universalist account claims that abstract concepts like time are universal across humans. In contrast, the linguistic relativity hypothesis holds that speakers of different languages represent duration differently. The precise impact of language on duration representation is, however, unknown. Here, we show that language can have a powerful role in transforming humans' psychophysical experience of time. Contrary to the universalist account, we found language-specific interference in a duration reproduction task, where stimulus duration conflicted with its physical growth. When reproducing duration, Swedish speakers were misled by stimulus length, and Spanish speakers were misled by stimulus size/quantity. These patterns conform to preferred expressions of duration magnitude in these languages (Swedish: long/short time; Spanish: much/small time). Critically, Spanish-Swedish bilinguals performing the task in both languages showed different interference depending on language context. Such shifting behavior within the same individual reveals hitherto undocumented levels of flexibility in time representation. Finally, contrary to the linguistic relativity hypothesis, language interference was confined to difficult discriminations (i.e., when stimuli varied only subtly in duration and growth), and was eliminated when linguistic cues were removed from the task. These results reveal the malleable nature of human time representation as part of a highly adaptive information processing system. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  8. Is it relevant? Influence of trial manipulations of prospective memory context on task interference.

    PubMed

    Lourenço, Joana S; Maylor, Elizabeth A

    2014-01-01

    Prospective memory (PM) research has often investigated if having an intention interferes with ongoing activities, but rarely by linking the intention to a particular context. We examined effects of trial-by-trial changes in whether the context (defined by colour) was relevant for the nonfocal PM task. The ongoing task involved speeded decisions about the position (left/right) of the upper-case letter in a pair, and the PM task consisted of pressing an additional key if the upper-case and lower-case letters were in a specified colour and the same letter. Trials switched between two colours either randomly or predictably in eight-trial blocks. We also manipulated the presence/absence of occasional same-letter pairs in the irrelevant context. Results showed higher cost of having a nonfocal PM task when ongoing stimuli matched than when they mismatched the target's colour. Moreover, cost for intention-irrelevant stimuli was minimized, though never eliminated, by blocking match/mismatch trials. These findings highlight the role that local changes in intention-related context play in task interference and support a view of monitoring as a flexible mechanism. Additionally, the study introduced a novel way of embedding intention-related events in the irrelevant context shortly before the occurrence of PM targets, with results tentatively suggesting that such events might impair target detection.

  9. Understanding pave-IR : background, use, and advanced techniques

    DOT National Transportation Integrated Search

    2010-01-01

    Why Has TxDOT Implemented Pave-IR? : Promote more uniform, higher quality pavements : Minimize/eliminate thermal segregation : Expand range of weather conditions for paving : Special Provision 341-024 : Contains option for contractor to use Pave-IR :...

  10. Influence of trabecular bone quality and implantation direction on press-fit mechanics.

    PubMed

    Damm, Niklas B; Morlock, Michael M; Bishop, Nicholas E

    2017-02-01

    Achieving primary stability of uncemented press-fit prostheses in patients with poor quality bone can involve axial implantation forces large enough to cause bone fracture. Radial implantation eliminates intraoperative impaction forces and could prevent this damage. Platens of two commercial implant surfaces ("Beaded" and "Flaked") were implanted onto trabecular bone specimens of varying quality in a press-fit simulator. Samples were implanted with varying interference, either axially (shear) or radially (normal). Push-in and pull-out forces were measured to assess stability. Microstructural changes in the bone were determined from μCT analysis. For force-defined implantation analysis, push-in and pull-out forces both increased proportionally with increasing radial force, independent of implantation direction, bone quality or implant surface. For position-defined implantation analysis, pull-out forces were generally found to increase with interference and to be greater for radial than axial implantation direction, and to be lower for poor quality bone. Bone density increased locally at the tested interface due to implantation, in particular for the Beaded surface under axial implantation. If a safe radial stress can be determined for cortical bone in a particular patient, the associated implantation force, and pull-out force which represents primary stability, can be directly derived, regardless of implantation direction, bone quality or implant surface. Radial implantation delivers primary stability that is no worse than that for axial implantation and may eliminate potentially damaging impaction forces. Development of implant designs based on this principal might improve implant fixation. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:224-233, 2017. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  11. Defining the molecular profile of planarian pluripotent stem cells using a combinatorial RNAseq, RNA interference and irradiation approach.

    PubMed

    Solana, Jordi; Kao, Damian; Mihaylova, Yuliana; Jaber-Hijazi, Farah; Malla, Sunir; Wilson, Ray; Aboobaker, Aziz

    2012-01-01

    Planarian stem cells, or neoblasts, drive the almost unlimited regeneration capacities of freshwater planarians. Neoblasts are traditionally described by their morphological features and by the fact that they are the only proliferative cell type in asexual planarians. Therefore, they can be specifically eliminated by irradiation. Irradiation, however, is likely to induce transcriptome-wide changes in gene expression that are not associated with neoblast ablation. This has affected the accurate description of their specific transcriptomic profile. We introduce the use of Smed-histone-2B RNA interference (RNAi) for genetic ablation of neoblast cells in Schmidtea mediterranea as an alternative to irradiation. We characterize the rapid, neoblast-specific phenotype induced by Smed-histone-2B RNAi, resulting in neoblast ablation. We compare and triangulate RNA-seq data after using both irradiation and Smed-histone-2B RNAi over a time course as means of neoblast ablation. Our analyses show that Smed-histone-2B RNAi eliminates neoblast gene expression with high specificity and discrimination from gene expression in other cellular compartments. We compile a high confidence list of genes downregulated by both irradiation and Smed-histone-2B RNAi and validate their expression in neoblast cells. Lastly, we analyze the overall expression profile of neoblast cells. Our list of neoblast genes parallels their morphological features and is highly enriched for nuclear components, chromatin remodeling factors, RNA splicing factors, RNA granule components and the machinery of cell division. Our data reveal that the regulation of planarian stem cells relies on posttranscriptional regulatory mechanisms and suggest that planarians are an ideal model for this understudied aspect of stem cell biology.

  12. [Screening and identification of apolipoprotein A-I as a potential marker for hepatoblastoma in children].

    PubMed

    Guo, Li-Hua; Zhao, Wei; Zhang, Jun-Jie; Zhang, Qian; Fan, Ying-Zhong; Wang, Jia-Xiang

    2016-12-01

    To screen and identify serum biomarkers for childhood hepatoblastoma (HB). The serum samples from 30 children with hepatoblastoma (HB), 20 children with systemic inflammatory response syndrome, and 20 normal children were treated with magnetic bead-based weak cation exchange chromatography. The platform of surface-enhanced laser desorption/ionization-time of flight-mass spectrometry (SELDI-TOF-MS) was used to eliminate the interference of inflammatory factors and to screen out the differentially expressed proteins in serum between tumor group and normal group. After the purification and separation of target proteins were performed using sodium dodecyl sulfate-polyacrylamide gel electrophoresis, matrix-assisted laser desorption/ionization-time of flight-mass spectrometry was used to determine their amino acid sequences. The SwissProt database was searched for matched proteins. Finally, real-time PCR and ELISA were used to verify and measure the expression of target proteins. After SELDI-TOF-MS was used for screening and elimination of the interference of inflammatory factors, a differentially expression protein with a mass-to-charge ratio of 9 348 Da was found in serum between HB group and normal group, and the HB group had significantly lower expression of this protein than the normal group (p<0.05). This protein was identified as apolipoprotein A-1 (Apo A-I). Real-time PCR and ELISA verified the low mRNA and protein expression of Apo A-I in serum in the HB group and high expression in serum in the normal group. Apo A-I can be used as a non-inflammatory protein marker for HB and has a certain value in the early diagnosis of HB.

  13. Ultrasensitive determination of cadmium in seawater by hollow fiber supported liquid membrane extraction coupled with graphite furnace atomic absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Peng, Jin-feng; Liu, Rui; Liu, Jing-fu; He, Bin; Hu, Xia-lin; Jiang, Gui-bin

    2007-05-01

    A new procedure, based on hollow fiber supported liquid membrane preconcentration coupled with graphite furnace atomic absorption spectrometry (GFAAS) detection, was developed for the determination of trace Cd in seawater samples. With 1-octanol that contained a mixture of dithizone (carrier) and oleic acid immobilized in the pores of the polypropylene hollow fiber as a liquid membrane, Cd was selectively extracted from water samples into 0.05 M HNO 3 that filled the lumen of the hollow fiber as a stripping solution. The main extraction related parameters were optimized, and the effects of salinity and some coexisting interferants were also evaluated. Under the optimum extraction conditions, an enrichment factor of 387 was obtained for a 100-mL sample solution. In combination with graphite furnace atomic absorption spectrometry, a very low detection limit (0.8 ng L - 1 ) and a relative standard deviation (2.5% at 50 ng L - 1 level) were achieved. Five seawater samples were analyzed by the proposed method without dilution, with detected Cd concentration in the range of 56.4-264.8 ng L - 1 and the relative spiked recoveries over 89%. For comparison, these samples were also analyzed by the Inductively Coupled Plasma Mass Spectrometry (ICP-MS) method after a 10-fold dilution for matrix effect elimination. Statistical analysis with a one-way ANOVA shows no significant differences (at 0.05 level) between the results obtained by the proposed and ICP-MS methods. Additionally, analysis of certified reference materials (GBW (E) 080040) shows good agreement with the certified value. These results indicate that this present method is very sensitive and reliable, and can effectively eliminate complex matrix interferences in seawater samples.

  14. Validation and Application of the MD Anderson Symptom Inventory for Traditional Chinese Medicine (MDASI-TCM).

    PubMed

    Li, Zhandong; Shi, Qiuling; Liu, Meng; Jia, Liqun; He, Bin; Yang, Yufei; Liu, Jie; Lin, Hongsheng; Lin, Huei-Kai; Li, Pingping; Wang, Xin Shelley

    2017-11-01

    The MD Anderson Symptom Inventory (MDASI) is a brief, yet thorough, patient-reported outcomes measure for assessing the severity of common cancer-related symptoms and their interference with daily functioning. We report the development of an MDASI version tailored for use with Traditional Chinese Medicine in China (the MDASI-TCM). Chinese-speaking patients with mixed cancer types (n = 317) participated in the study. The development and validation process included four steps: 1) identify candidate TCM-specific items, with input from patients, oncologists, and TCM specialists; 2) eliminate candidate TCM items lacking relevance, based on patient report; 3) psychometrically examine the MDASI-TCM's validity and reliability in cancer patients receiving TCM-based care; and 4) cognitively debrief patients to assess the MDASI-TCM's relevance, understandability, and acceptability. Seven TCM-specific symptom items (sweating, feeling cold, constipation, bitter taste, coughing, palpitations, and heat in palms/soles) were clinically and psychometrically meaningful to add to the core MDASI. Approximately 61% of patients had moderate to severe symptoms (rated ≥5 on the MDASI-TCM's 0-10 scale). Cronbach α coefficients were .90 for symptom-severity items and .93 for interference items, indicating internal consistency reliability. Known-group validity was substantiated by the MDASI-TCM's detection of differences in symptom severity according to performance status (P < .001) and interference levels by cancer stage (P < .05). Cognitive debriefing indicated that patients found the MDASI-TCM to be an understandable, easy-to-use tool. The Chinese MDASI-TCM is a valid, reliable, and concise measure of symptom severity and interference that can be used to assess Chinese cancer patients and survivors receiving TCM-based care. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  15. Multielement extraction system for determining 19 trace elements in gold exploration samples

    USGS Publications Warehouse

    Clark, J. Robert; Viets, John G.; ,

    1990-01-01

    A multielement extraction system is being used successfully to provide essentially interference-free geochemical analyses to aid in gold exploration. The Methyl isobutyl ketone-Amine synerGistic Iodide Complex (MAGIC) extraction system separates Ag, As, Au, Bi, Cd, Cu, Ga, Hg, In, Mo, Pb, Pd, Pt, Sb, Se, Sn, Te, Tl, and Zn from interfering geological matrices. Quantitative extraction of these elements is accomplished over a broad range of acid normality making it possible to economically determine all 19 elements from a single digestion or leach solution. The resulting organic extracts are amenable to analysis by inductively coupled plasma atomic emission spectroscopy (ICP-AES) and flame atomic absorption spectroscopy (FAAS). For many years the principal shortcoming of ICP-AES was the complex spectral and stray-light interferences that were caused by the extreme variability of components such as Fe, Na, and Ca in common geological matrices. The MAGIC extraction allows determination of the extracted elements with enhanced sensitivity, from a virtually uniform matrix, by ICP-AES and FAAS. Because of its simultaneous multichannel capabilities, ICP-AES is the ideal instrumental technique for determining these 19 extracted elements. Ultratrace (sub-part-per-billion) determinations of Au and many of the other extracted elements can be made by graphite furnace atomic absorption spectroscopy (GFAAS), following back stripping of the extracts. The combination of the extraction followed by stripping of the organic phase eliminates 99.999% of potential interferences for Au. Gold determination by GFAAS from these extracts under the specified conditions yields a fourfold improvement in sensitivity over conventional GFAAS methods. This sensitivity enhancement and the interference-free matrix allow highly reliable determinations well into the parts-per-trillion range.

  16. Norm-Referenced Tests and Race-Blind Admissions: The Case for Eliminating the SAT and ACT at the University of California. Research & Occasional Paper Series: CSHE.15.17

    ERIC Educational Resources Information Center

    Geiser, Saul

    2017-01-01

    Of all college admission criteria, scores on nationally normed tests like the SAT and ACT are most affected by the socioeconomic background of the student. The effect of socioeconomic background on test scores has grown substantially at University of California over the past two decades, and tests have become more of a barrier to admission of…

  17. Scalar production and decay to top quarks including interference effects at NLO in QCD in an EFT approach

    DOE PAGES

    Franzosi, Diogo Buarque; Vryonidou, Eleni; Zhang, Cen

    2017-10-13

    Scalar and pseudo-scalar resonances decaying to top quarks are common predictions in several scenarios beyond the standard model (SM) and are extensively searched for by LHC experiments. Challenges on the experimental side require optimising the strategy based on accurate predictions. Firstly, QCD corrections are known to be large both for the SM QCD background and for the pure signal scalar production. Secondly, leading order and approximate next-to-leading order (NLO) calculations indicate that the interference between signal and background is large and drastically changes the lineshape of the signal, from a simple peak to a peak-dip structure. Therefore, a robust predictionmore » of this interference at NLO accuracy in QCD is necessary to ensure that higher-order corrections do not alter the lineshapes. We compute the exact NLO corrections, assuming a point-like coupling between the scalar and the gluons and consistently embedding the calculation in an effective field theory within an automated framework, and present results for a representative set of beyond the SM benchmarks. The results can be further matched to parton shower simulation, providing more realistic predictions. We find that NLO corrections are important and lead to a significant reduction of the uncertainties. We also discuss how our computation can be used to improve the predictions for physics scenarios where the gluon-scalar loop is resolved and the effective approach is less applicable.« less

  18. Background reduction in 236U/238U measurements

    NASA Astrophysics Data System (ADS)

    Buompane, Raffaele; De Cesare, Mario; De Cesare, Nicola; Di Leva, Antonino; D'Onofrio, Antonio; Fifield, L. Keith; Fröhlich, Michaela; Gialanella, Lucio; Marzaioli, Fabio; Sabbarese, Carlo; Terrasi, Filippo; Tims, Stephen; Wallner, Anton

    2015-10-01

    The measurements of actinide isotopic ratios, in particular 236U/238U, in environmental samples requires high sensitivity. In particular, special effort must be devoted to the suppression of interfering nuclides, such as 235,238U, when measuring 236U. At the AMS facility of CIRCE, isotopic ratios down to ∼10-10 are currently measured using a gas E - ΔE detector. In order to push this limit lower towards natural levels, a time-of-flight system is used, featuring a micro-channel plate start detector and a Si stop detector. As the mass resolution of the latter is limited by the layout, an attempt to reduce the abundant isotope interference by other means has been undertaken. In this study, we report preliminary results on the characterization of the presence of molecular interferences when using UO-, UC- and UC2- as injected molecular ions. In particular the possibility to stabilize the current yield from carbide cathodes has been investigated: it was found that the best cathode preparation procedure is obtained pressing U salts baked at 800 °C mixed with graphite and Al powder. Moreover, the 238U background in 236U measurements is strongly reduced injecting UC- ions, as verified using a time-of-flight detection system. On the other hand, 235U interference is larger with respect to UO- injection, but this increase is smaller than expected on the basis of abundances of 13C and 17O in UC and UC2 molecules on one side and UO, on the other.

  19. Scalar production and decay to top quarks including interference effects at NLO in QCD in an EFT approach

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Franzosi, Diogo Buarque; Vryonidou, Eleni; Zhang, Cen

    Scalar and pseudo-scalar resonances decaying to top quarks are common predictions in several scenarios beyond the standard model (SM) and are extensively searched for by LHC experiments. Challenges on the experimental side require optimising the strategy based on accurate predictions. Firstly, QCD corrections are known to be large both for the SM QCD background and for the pure signal scalar production. Secondly, leading order and approximate next-to-leading order (NLO) calculations indicate that the interference between signal and background is large and drastically changes the lineshape of the signal, from a simple peak to a peak-dip structure. Therefore, a robust predictionmore » of this interference at NLO accuracy in QCD is necessary to ensure that higher-order corrections do not alter the lineshapes. We compute the exact NLO corrections, assuming a point-like coupling between the scalar and the gluons and consistently embedding the calculation in an effective field theory within an automated framework, and present results for a representative set of beyond the SM benchmarks. The results can be further matched to parton shower simulation, providing more realistic predictions. We find that NLO corrections are important and lead to a significant reduction of the uncertainties. We also discuss how our computation can be used to improve the predictions for physics scenarios where the gluon-scalar loop is resolved and the effective approach is less applicable.« less

  20. [Wireless human body communication technology].

    PubMed

    Sun, Lei; Zhang, Xiaojuan

    2014-12-01

    The Wireless Body Area Network (WBAN) is a key part of the wearable monitoring technologies, which has many communication technologies to choose from, like Bluetooth, ZigBee, Ultra Wideband, and Wireless Human Body Communication (WHBC). As for the WHBC developed in recent years, it is worthy to be further studied. The WHBC has a strong momentum of growth and a natural advantage in the formation of WBAN. In this paper, we first briefly describe the technical background of WHBC, then introduce theoretical model of human-channel communication and digital transmission machine based on human channel. And finally we analyze various of the interference of the WHBC and show the AFH (Adaptive Frequency Hopping) technology which can effectively deal with the interference.

Top