Fablet, C; Rose, N; Bernard, C; Messager, I; Piel, Y; Grasland, B
2017-11-01
This study was designed to assess the diagnostic characteristics of two PCV2 ELISAs without a gold standard. Four hundred and sixty-five serum samples from finishing pigs (25 herds) not vaccinated against PCV2 were used. Samples were tested by two ELISAs: an in-house ELISA (I-ELISA) and the commercial SERELISA ® PCV2 Ab Mono Blocking kit (S-ELISA). A ROC curve was used to assess the S-ELISA's optimal threshold by taking the I-ELISA as a reference and using the cut-off previously determined by comparison to an cccmonolayer assay (IPMA). This led to an S-ELISA result ≥170 being considered as positive. The sensitivity (Se) and specificity (Sp) of each ELISA were then estimated without a gold standard using a Bayesian approach. The mean Se and Sp values of the I-ELISA were slightly higher than those of the S-ELISA (mean Se I-ELISA=0.90 vs. mean Se S-ELISA=0.86; mean Sp I-ELISA=0.92 vs. mean Sp S-ELISA=0.85). However, the 95% credibility intervals (CI95%) overlapped (Se I-ELISA CI95%=0.85-0.95 vs. Se S-ELISA CI95%=0.82-0.90; Sp I-ELISA CI95%=0.82-0.98 vs. Sp S-ELISA CI95%=0.75-0.94). Both ELISAs appeared to be valuable tools for detecting PCV2 antibodies. Copyright © 2017 Elsevier B.V. All rights reserved.
Sattler, Tatjana; Wodak, Eveline; Revilla-Fernández, Sandra; Schmoll, Friedrich
2014-12-18
In recent years, several new ELISAs for the detection of antibodies against the porcine reproductive and respiratory disease virus (PRRSV) in pig serum have been developed. To interpret the results, specificity and sensitivity data as well as agreement to a reference ELISA must be available. In this study, three commercial ELISAs (INgezim PRRS 2.0 - ELISA II, Priocheck® PRRSV Ab porcine - ELISA III and CIVTEST suis PRRS E/S PLUS - ELISA IV, detecting PRRSV type 1 antibodies) were compared to a standard ELISA (IDEXX PRRS X3 Ab Test - ELISA I). The serum of three pigs vaccinated with an attenuated PRRSV live vaccine (genotype 2) was tested prior to and several times after the vaccination. Furthermore, serum samples of 245 pigs of PRRSV positive herds, 309 pigs of monitored PRRSV negative herds, 256 fatteners of assumed PRRSV negative herds with unknown herd history and 92 wild boars were tested with all four ELISAs. ELISAs II and III were able to detect seroconversion of vaccinated pigs with a similar reliability. According to kappa coefficient, the results showed an almost perfect agreement between ELISA I as reference and ELISA II and III (kappa > 0.8), and substantial agreement between ELISA I and ELISA IV (kappa = 0.71). Sensitivity of ELISA II, III and IV was 96.0%, 100% and 91.5%, respectively. The specificity of the ELISAs determined in samples of monitored PRRSV negative herds was 99.0%, 95.1% and 96.4%, respectively. In assumed negative farms that were not continually monitored, more positive samples were found with ELISA II to IV. The reference ELISA I had a specificity of 100% in this study. All tested ELISAs were able to detect a PRRSV positive herd. The specificity and sensitivity of the tested commercial ELISAs, however, differed. ELISA II had the highest specificity and ELISA III had the highest sensitivity in comparison to the reference ELISA. ELISA IV had a lower sensitivity and specificity than the other ELISAs.
Decline of maternal antibodies to small ruminant lentivirus in goat kids.
Czopowicz, Michał; Szaluś-Jordanow, Olga; Mickiewicz, Marcin; Moroz, Agata; Witkowski, Lucjan; Markowska-Daniel, Iwona; Reczyńska, Daria; Bagnicka, Emilia; Kaba, Jarosław
2018-06-06
We carried out this study to determine for how long small ruminant lentivirus (SRLV)-specific antibodies can be detected by three commercial ELISA kits in goat kids after suckling infected does in field conditions. Forty-one kids born to SRLV-seropositive asymptomatic does were blood sampled prior to colostrum consumption, and then weekly for 6 months in total. The sera were screened with three commercial ELISA kits: whole-virus ELISA (wELISA), recombinant transmembrane and capsid antigen ELISA (TM/CA-ELISA), and surface antigen ELISA (SU-ELISA). All but one kid were seronegative in all three ELISAs right after birth. At the age of 1 week all kids turned seropositive in wELISA, 39 kids (95%) in TM/CA-ELISA, and 35 kids (85%) in SU-ELISA. All seropositive kids turned seronegative in wELISA by the 15th week, and in SU-ELISA by the 19th week (median of 8 weeks in both ELISA), whereas in TM/CA-ELISA five kids (13% of 39 initially seropositive) were still seropositive at the age of 6 months (median of 11 weeks). Antibody levels at the age of 1 week proved significantly linked to the duration of maternal antibodies in all three ELISAs and could be employed to predict for how long maternal antibodies would remain detectable. © 2018 Japanese Society of Animal Science.
Sugden, E A; Stilwell, K; Rohonczy, E B; Martineau, P
1997-01-01
A competitive enzyme-linked immunosorbent assay (C-ELISA) using M. bovis BCG Tokyo culture filtrate as antigen and anti-MPB70 4C3/17 monoclonal antibody was developed for use in multiple animal species. An analysis of the C-ELISA data for cattle and bison serum panels revealed specificities of 68% to 85% and sensitivities of 85% to 89%. Receiver operator characteristics (ROC) of this data revealed areas of 81% to 92% for C-ELISA and demonstrated that C-ELISA as well as the indirect ELISA protocols, MPB70-ELISA and LAM-ELISA, discriminate M. bovis infected animals from non-infected animals for these particular panels. The kappa statistic values for agreement beyond chance between C-ELISA and MPB70-ELISA were determined after ELISA cutoffs were adjusted to minimize false positives. There were poor to excellent agreements between C-ELISA and MPB70-ELISA in all species tested (Bovidae, Cervidae, and Camelidae) that were consistently higher than the kappa statistic between C-ELISA and LAM-ELISA. The humoral response to one antigen and little or no response to the other in many animals argued for a parallel interpretation of C-ELISA and LAM-ELISA to increase sensitivity. PMID:9008794
Elisa Miller Photo of Elisa Miller Elisa Link-Miller Researcher III-Chemistry Elisa.Miller@nrel.gov | 303-384-6777 Dr. Elisa Miller-Link studies the surface of semiconductors that are applicable for , and other nanocrystalline films. Elisa came to NREL in 2013 as an NREL Director's Fellowship recipient
[Effect evaluation of three ELISA kits in detection of fasciolasis].
Ai, Lin; Chen, Mu-Xin; Chen, Shao-Hong; Chu, Yan-Hong; Cai, Yu-Chun; Zhou, Xiao-Nong; Chen, Jia-Xu
2013-04-01
To evaluate the effect of 3 ELISA kits on detection of human fasciolasis. Twenty-six serum samples from patients with fasciolasis, 180 serum samples from patients with other parasitic diseases as well as 26 serum samples from healthy people were detected by ELISA kits which using soluble antigen of Fasciola gigantica, Fasciola hepatica (Fg-ELISA and Fh-ELISA) as well as IgG antigen ELISA detection kits made by DRG company in Germany. The effects of the 3 kits were evaluated. The sensitivities of Fg-ELISA, Fh-ELISA, and DRG-ELISA were 100.0%, 80.8% (95% CI: 65.7%-95.9%) and 100.0%, respectively; the specificities of the three were 87.9% (95% CI: 83.5%-92.4%), 85.0%(95% CI: 80.1%-89.9%) and 83.5% (95% CI: 78.4%-88.6%), respectively, and Youden indexes of them were 0.88, 0.66 and 0.84, respectively. The detection rate of Fg-ELISA (100%) was significantly higher than that of Fh-ELISA (80.8%) (P < 0.05). The A absolute value (A/CO) of Fg-ELISA was 1.70, which was also significantly higher than the value of Fh-ELISA (1.18) (P < 0.000 1). Fg-ELISA has a good detection effect and low cost, and is more suitable than Fh-ELISA and DRG-ELISA for clinical sample tests as well as massive screening in fasciolasis endemic areas in southwest China.
Morioka, Kazuki; Fukai, Katsuhiko; Sakamoto, Kenichi; Yoshida, Kazuo; Kanno, Toru
2014-01-01
A monoclonal antibody-based sandwich direct ELISA (MSD-ELISA) method was previously developed for foot-and-mouth disease (FMD) viral antigen detection. Here we evaluated the sensitivity and specificity of two FMD viral antigen detection MSD-ELISAs and compared them with conventional indirect sandwich (IS)-ELISA. The MSD-ELISAs were able to detect the antigen in saliva samples of experimentally-infected pigs for a longer term compared to the IS-ELISA. We also used 178 RT-PCR-positive field samples from cattle and pigs affected by the 2010 type-O FMD outbreak in Japan, and we found that the sensitivities of both MSD-ELISAs were about 7 times higher than that of the IS-ELISA against each sample (P<0.01). In terms of the FMD-positive farm detection rate, the sensitivities of the MSD-ELISAs were about 6 times higher than that of the IS-ELISA against each farm (P<0.01). Although it is necessary to conduct further validation study using the other virus strains, MSD-ELISAs could be appropriate as a method to replace IS-ELISA for FMD antigen detection.
Prieto, José M; Balseiro, Ana; Casais, Rosa; Abendaño, Naiara; Fitzgerald, Liam E; Garrido, Joseba M; Juste, Ramon A; Alonso-Hearn, Marta
2014-08-01
The enzyme-linked immunosorbent assay (ELISA) is the diagnostic test most commonly used in efforts to control paratuberculosis in domestic ruminants. However, commercial ELISAs have not been validated for detecting antibodies against Mycobacterium avium subsp. paratuberculosis in wild animals. In this study, we compared the sensitivities and specificities of five ELISAs using individual serum samples collected from 41 fallow deer with or without histopathological lesions consistent with paratuberculosis. Two target antigenic preparations were selected, an ethanol-treated protoplasmic preparation obtained from a fallow deer M. avium subsp. paratuberculosis isolate (ELISAs A and B) and a paratuberculosis protoplasmic antigen (PPA3) (ELISAs C and D). Fallow deer antibodies bound to the immobilized antigens were detected by using a horseradish peroxidase (HRP)-conjugated anti-fallow deer IgG antibody (ELISAs A and C) or HRP-conjugated protein G (ELISAs B and D). A commercially available assay, ELISA-E, which was designed to detect M. avium subsp. paratuberculosis antibodies in cattle, sheep, and goats, was also tested. Although ELISAs A, C, and E had the same sensitivity (72%), ELISAs A and C were more specific (100%) for detecting fallow deer with lesions consistent with paratuberculosis at necropsy than was the ELISA-E (87.5%). In addition, the ELISA-A was particularly sensitive for detecting fallow deer in the latent stages of infection (62.5%). The antibody responses detected with the ELISA-A correlated with both the severity of enteric lesions and the presence of acid-fast bacteria in gut tissue samples. In summary, our study shows that the ELISA-A can be a cost-effective diagnostic tool for preventing the spread of paratuberculosis among fallow deer populations. Copyright © 2014, American Society for Microbiology. All Rights Reserved.
Prieto, José M.; Balseiro, Ana; Casais, Rosa; Abendaño, Naiara; Fitzgerald, Liam E.; Garrido, Joseba M.; Juste, Ramon A.
2014-01-01
The enzyme-linked immunosorbent assay (ELISA) is the diagnostic test most commonly used in efforts to control paratuberculosis in domestic ruminants. However, commercial ELISAs have not been validated for detecting antibodies against Mycobacterium avium subsp. paratuberculosis in wild animals. In this study, we compared the sensitivities and specificities of five ELISAs using individual serum samples collected from 41 fallow deer with or without histopathological lesions consistent with paratuberculosis. Two target antigenic preparations were selected, an ethanol-treated protoplasmic preparation obtained from a fallow deer M. avium subsp. paratuberculosis isolate (ELISAs A and B) and a paratuberculosis protoplasmic antigen (PPA3) (ELISAs C and D). Fallow deer antibodies bound to the immobilized antigens were detected by using a horseradish peroxidase (HRP)-conjugated anti-fallow deer IgG antibody (ELISAs A and C) or HRP-conjugated protein G (ELISAs B and D). A commercially available assay, ELISA-E, which was designed to detect M. avium subsp. paratuberculosis antibodies in cattle, sheep, and goats, was also tested. Although ELISAs A, C, and E had the same sensitivity (72%), ELISAs A and C were more specific (100%) for detecting fallow deer with lesions consistent with paratuberculosis at necropsy than was the ELISA-E (87.5%). In addition, the ELISA-A was particularly sensitive for detecting fallow deer in the latent stages of infection (62.5%). The antibody responses detected with the ELISA-A correlated with both the severity of enteric lesions and the presence of acid-fast bacteria in gut tissue samples. In summary, our study shows that the ELISA-A can be a cost-effective diagnostic tool for preventing the spread of paratuberculosis among fallow deer populations. PMID:24872517
ELISA-BASE: An Integrated Bioinformatics Tool for Analyzing and Tracking ELISA Microarray Data
DOE Office of Scientific and Technical Information (OSTI.GOV)
White, Amanda M.; Collett, James L.; Seurynck-Servoss, Shannon L.
ELISA-BASE is an open-source database for capturing, organizing and analyzing protein enzyme-linked immunosorbent assay (ELISA) microarray data. ELISA-BASE is an extension of the BioArray Soft-ware Environment (BASE) database system, which was developed for DNA microarrays. In order to make BASE suitable for protein microarray experiments, we developed several plugins for importing and analyzing quantitative ELISA microarray data. Most notably, our Protein Microarray Analysis Tool (ProMAT) for processing quantita-tive ELISA data is now available as a plugin to the database.
Pomes, M.L.; Thurman, E.M.; Aga, D.S.; Goolsby, D.A.
1998-01-01
Triazine and chloroacetanilide concentrations in rainfall samples collected from a 23-state region of the United States were analyzed with microtiter-plate enzyme-linked immunosorbent assay (ELISA). Thirty-six percent of rainfall samples (2072 out of 5691) were confirmed using gas chromatography/mass spectrometry (GC/MS) to evaluate the operating performance of ELISA as a screening test. Comparison of ELISA to GC/MS results showed that the two ELISA methods accurately reported GC/MS results (m = 1), but with more variability evident with the triazine than with the chloroacetanilide ELISA. Bayes's rule, a standardized method to report the results of screening tests, indicated that the two ELISA methods yielded comparable predictive values (80%), but the triazine ELISA yielded a false- positive rate of 11.8% and the chloroacetanilide ELISA yielded a false- negative rate of 23.1%. The false-positive rate for the triazine ELISA may arise from cross reactivity with an unknown triazine or metabolite. The false-negative rate of the chloroacetanilide ELISA probably resulted from a combination of low sensitivity at the reporting limit of 0.15 ??g/L and a distribution characterized by 75% of the samples at or below the reporting limit of 0.15 ??g/L.Triazine and chloroacetanilide concentrations in rainfall samples collected from a 23-state region of the United States were analyzed with microtiter-plate enzyme-linked immunosorbent assay (ELISA). Thirty-six percent of rainfall samples (2072 out of 5691) were confirmed using gas chromatography/mass spectrometry (GC/MS) to evaluate the operating performance of ELISA as a screening test. Comparison of ELISA to GC/MS results showed that the two ELISA methods accurately reported GC/MS results (m = 1), but with more variability evident with the triazine than with the chloroacetanilide ELISA. Bayes's rule, a standardized method to report the results of screening tests, indicated that the two ELISA methods yielded comparable predictive values (80%), but the triazine ELISA yielded a false-positive rate of 11.8% and the chloroacetanilide ELISA yielded a false-negative rate of 23.1%. The false-positive rate for the triazine ELISA may arise from cross reactivity with an unknown triazine or metabolite. The false-negative rate of the chloroacetanilide ELISA probably resulted from a combination of low sensitivity at the reporting limit of 0.15 ??g/L and a distribution characterized by 75% of the samples at or below the reporting limit of 0.15 ??g/L.
Mårtensson, Johan; Xu, Shengyuan; Bell, Max; Martling, Claes-Roland; Venge, Per
2012-10-09
The distinction between monomeric human neutrophil lipocalin/neutrophil gelatinase-associated lipocalin (HNL/NGAL), secreted by injured kidney tubular cells, and dimeric HNL/NGAL, released by activated neutrophils, is important to accurately diagnose acute kidney injury (AKI). 132 urine samples from 44 intensive care unit (ICU) patients and five urine samples from non-ICU patients with urinary tract infections (UTIs) were analyzed by two monoclonal enzyme-linked immunosorbent assays (ELISA-1 and ELISA-2). The presence of monomeric and/or dimeric HNL/NGAL in each sample was visualized by Western blotting. The ELISA-1 detected both monomeric and dimeric HNL/NGAL whereas the ELISA-2 almost exclusively detected dimeric HNL/NGAL with an area under the receiver-operating characteristics curve (AuROC) of 0.90. The ELISA-1/ELISA-2 ratio detected the monomeric form with an AuROC of 0.92. In 32 AKI patients, dimer-specific ELISA-2 levels decreased pre-AKI whereas the monomer-specific ELISA-1/ELISA-2 ratio gradually increased beyond AKI diagnosis. High ELISA-2 levels and/or low ELISA-1/ELISA-2 ratios detected a predominance of dimeric HNL/NGAL in urine from the patients with UTIs. In combination, our two ELISAs distinguish monomeric HNL/NGAL, produced by the kidney epithelium, from dimeric HNL/NGAL, released by neutrophils during AKI development, as well as reduce the confounding effect of neutrophil involvement when bacteriuria is present. Copyright © 2012 Elsevier B.V. All rights reserved.
Teimouri, Aref; Modarressi, Mohammad Hossein; Shojaee, Saeedeh; Mohebali, Mehdi; Zouei, Nima; Rezaian, Mostafa; Keshavarz, Hossein
2018-05-08
In the current study, performance of electrochemiluminescence immunoassay (ECLIA) in detection of anti-toxoplasma IgG in human sera was compared with that of enzyme-linked immunosorbent assay (ELISA). Furthermore, performance of an in house Dot-ELISA in detection of anti-toxoplasma IgG was compared with that of ECLIA and ELISA. In total, 219 human sera were tested to detect anti-toxoplasma IgG using Dynex DS2® and Roche Cobas® e411 Automated Analyzers. Discordant results rechecked using immunofluorescence assay (IFA). Then, sera were used in an in house Dot-ELISA to assess toxoplasma-specific IgG. Of the 219 samples, two samples were found undetermined using ECLIA but reactive using ELISA. Using IFA, the two sera were reported unreactive. Furthermore, two samples were found reactive using ECLIA and unreactive using ELISA. These samples were reported reactive using IFA. The overall agreement for the two former methods was 98% (rZ0.98.1; P < 0.001). The intrinsic parameters calculated for in house Dot-ELISA included sensitivity of 79.5, specificity of 78.2, and accuracy of 78.9%, compared to ECLIA and ELISA. Positive and negative predictive values included 82.9 and 74.2%, respectively. A 100% sensitivity was found in in house Dot-ELISA for highly reactive sera in ECLIA and ELISA. ECLIA is appropriate for the first-line serological screening tests and can replace ELISA due to high speed, sensitivity, and specificity, particularly in large laboratories. Dot-ELISA is a rapid, sensitive, specific, cost-effective, user-friendly, and field-portable technique and hence can be used for screening toxoplasmosis, especially in rural fields or less equipped laboratories.
Villa-Mancera, Abel; Molina-Mendoza, Pedro; Hernández-Guzmán, Karina; Olivares-Pérez, Jaime; Sarracent-Pérez, Jorge; Zumaquero-Ríos, José
2016-01-01
The objective of present study was to determine the prevalence of natural caprine fasciolosis in the Mixteca region of Mexico using coproantigen and serum IgG1 ELISA tests for comparative purposes. A total of 1070 serum and faecal samples were analyzed for IgG1 antibodies and coproantigens, using ELISA with E/S products as antigen and a monoclonal antibody-based sandwich ELISA. Prevalence of 73.46% was found using the serological ELISA and a percentage of 77.20 was found for coproantigen ELISA. The diagnostic sensitivity and specificity for serum ELISA were 86.7% and 96.4%, and for the coproantigen ELISA they were 93.1% and 97.8%, respectively. The seropositive samples were further categorized as low, medium, or high positivity. Results show a great proportion of low and medium positive goats when the serum ELISA test was used. Correlation coefficients between coproantigens and seropositivity were statistically significant (P < 0.01) for low seropositivity (r = 0.93) and medium seropositivity (r = 0.84). The accuracy of faecal antigen ELISA was higher compared to indirect ELISA serological test. Two ELISAs were shown to be useful for demonstrating the current status of F. hepatica infection in the endemic areas and can be employed in studies on epidemiology as well as anthelmintics treatment for preventing economic loss and the risk of transmission to humans.
Molina-Mendoza, Pedro; Hernández-Guzmán, Karina; Olivares-Pérez, Jaime; Sarracent-Pérez, Jorge; Zumaquero-Ríos, José
2016-01-01
The objective of present study was to determine the prevalence of natural caprine fasciolosis in the Mixteca region of Mexico using coproantigen and serum IgG1 ELISA tests for comparative purposes. A total of 1070 serum and faecal samples were analyzed for IgG1 antibodies and coproantigens, using ELISA with E/S products as antigen and a monoclonal antibody-based sandwich ELISA. Prevalence of 73.46% was found using the serological ELISA and a percentage of 77.20 was found for coproantigen ELISA. The diagnostic sensitivity and specificity for serum ELISA were 86.7% and 96.4%, and for the coproantigen ELISA they were 93.1% and 97.8%, respectively. The seropositive samples were further categorized as low, medium, or high positivity. Results show a great proportion of low and medium positive goats when the serum ELISA test was used. Correlation coefficients between coproantigens and seropositivity were statistically significant (P < 0.01) for low seropositivity (r = 0.93) and medium seropositivity (r = 0.84). The accuracy of faecal antigen ELISA was higher compared to indirect ELISA serological test. Two ELISAs were shown to be useful for demonstrating the current status of F. hepatica infection in the endemic areas and can be employed in studies on epidemiology as well as anthelmintics treatment for preventing economic loss and the risk of transmission to humans. PMID:27563665
George, Sergio; Mamani, Nora; Lucero, Yalda; Torres, Juan Pablo; Farfán, Mauricio; Lagomarcino, Anne J; Orellana, Andrea; O'Ryan, Miguel
2016-12-01
We previously detected Helicobacter pylori infection by stool antigen ELISA assay in 33-41% of asymptomatic Chilean children between 2-3 years of age, of which 11-20% had a transient infection and 21-22% a persistent infection. A total of 88% of ELISA-positive samples were also rtPCR positive, while 37/133 (33%) of ELISA-negative stool samples were rtPCR positive. The significance of a ELISA-negative/rtPCR-positive sample requires clarification. We aimed to determine whether rtPCR is able to detect persistent infections not detected by ELISA. We selected 36 children with an ELISA-negative/rtPCR-positive stool sample, of which 25 were never H. pylori infected according to ELISA, and 11 had a transient infection with an ELISA-positive sample before or after the discordant sample. At least two additional consecutive ELISA-negative samples per child were tested in duplicate by rtPCR for the 16s rRNA gene. A total of 14 of 78 (17.9%) rtPCR reactions were positive, but only 4/78 (5.1%) were positive in both duplicates, representing a total of 3/36 (8.3%) children with an additional rtPCR-positive sample, only one of whom was persistently negative by ELISA. One child with a transient infection had two positive rtPCR reactions despite negative ELISA samples. In H. pylori noninfected or transiently infected children, as determined by stool ELISA, additional ELISA-negative/rtPCR-positive stool samples were found in 8.3% of children, but a possible persistent infection was only identified in 2.7% of children. Thus, the characterization of infection dynamics in children is not being misrepresented by application of stool ELISA. Furthermore, rtPCR does not significantly improve dynamic characterization. © 2016 John Wiley & Sons Ltd.
Increased Sensitivity of HIV-1 p24 ELISA Using a Photochemical Signal Amplification System.
Bystryak, Simon; Santockyte, Rasa
2015-10-01
In this study we describe a photochemical signal amplification method (PSAM) for increasing of the sensitivity of enzyme-linked immunosorbent assay (ELISA) for determination of HIV-1 p24 antigen. The photochemical signal amplification method is based on an autocatalytic photochemical reaction of a horseradish peroxidase (HRP) substrate, orthophenylenediamine (OPD). To compare the performance of PSAM-boosted ELISA with a conventional colorimetric ELISA for determination of HIV-1 p24 antigen we employed a PerkinElmer HIV-1 p24 ELISA kit, using conventional ELISA alongside ELISA + PSAM. In the present study, we show that PSAM technology allows one to increase the analytical sensitivity and dynamic range of a commercial HIV-1 p24 ELISA kit, with and without immune-complex disruption, by a factor of approximately 40-fold. ELISA + PSAM is compatible with commercially available microtiter plate readers, requires only an inexpensive illumination device, and the PSAM amplification step takes no longer than 15 min. This method can be used for both commercially available and in-house ELISA tests, and has the advantage of being considerably simpler and less costly than alternative signal amplification methods. This method can be used for both commercially available and in-house ELISA tests, and has the advantage of being considerably simpler and less costly than alternative signal amplification methods.
[Evaluation of the Performance of Two Kinds of Anti-TP Enzyme-Linked Immunosorbent Assay].
Gao, Nan; Huang, Li-Qin; Wang, Rui; Jia, Jun-Jie; Wu, Shuo; Zhang, Jing; Ge, Hong-Wei
2018-06-01
To evaluate the accuracy and precision of 2 kinds of anti-treponema pallidum (anti-TP) ELISA reagents in our laboratory for detecting the anti-TP in voluntary blood donors, so as to provide the data support for use of ELISA reagents after introduction of chemiluminescene immunoassay (CLIA). The route detection of anti-TP was performed by using 2 kinds of ELISA reagents, then 546 responsive positive samples detected by anti-TP ELISA were collected, and the infections status of samples confirmed by treponema pallidum particle agglutination (TPPA) test was identified. The confirmed results of responsive samples detected by 2 kinds of anti-TP ELISA reagents were compared, the accuracy of 2 kinds of anti-TP ELISA reagents was analyzed by drawing ROC and comparing area under curve (AUC), and precision of 2 kinds of anti-TP ELISA reagents was compared by statistical analysis of quality control data from 7.1 2016 to 6.30 2017. There were no statistical difference in confirmed positive rate of responsive samples and weak positive samples between 2 kinds of anti-TP ELISA reagents. The responsive samples detected by 2 kinds of anti-TP ELISA reagents accounted for 85.53%(467/546) of all responsive samples, the positive rate confirmed by TPPA test was 82.87%. 44 responsive samples detected by anti-TP ELISA reagent A and 35 responsive samples detected by anti-TP ELISA reagent B were confirmed to be negative by TPPA test. Comparison of AUC showed that the accuracy of 2 kinds of anti-TP ELISA reagents was more high, the difference between 2 reagents was not statistically significant. The coefficient of variation (CV) of anti-TP ELISA reagent A and B was 14.98% and 18.04% respectively, which met the precision requirement of ELISA test. The accuracy and precision of 2 kinds of anti-TP ELISA reagents used in our laboratory are similar, and using any one of anti-TP ELISA reagents all can satisfy the requirements of blood screening.
Nakayasu, Miki; Hirano, Minato; Muto, Memi; Kobayashi, Shintaro; Kariwa, Hiroaki; Yoshii, Kentaro
2018-06-23
Tick-borne encephalitis virus (TBEV) is a zoonotic agent causing severe encephalitis in humans. IgM antibody detection is useful for the serological diagnosis of TBEV infection, because IgM has high specificity for each flavivirus and indicates a recent infection. Commercial IgM-ELISA kits are somewhat expensive and difficulties in their sensitivity have been suggested due to their format and formalin-inactivated antigens. Therefore, the development of an inexpensive IgM-ELISA with high specificity and sensitivity is needed. In this study, a μ-capture ELISA was developed to detect TBEV-specific IgM antibodies using subviral particles (SPs) with strep-tag (strep-SP-IgM-ELISA). The results of our strep-SP-IgM-ELISA were highly correlated with diagnoses made by the neutralization test (sensitivity: 94.1%), and our strep-SP-IgM-ELISA could detect anti-TBEV IgM antibodies in patients who could not be diagnosed with the neutralization test. Besides, 51 of 52 positive samples by a commercial IgM-ELISA were also diagnosed as positive by our strep-SP-IgM-ELISA (98.1%), and our strep-SP-IgM-ELISA could detect anti-TBEV IgM antibodies in all samples that were inconclusive based on the commercial IgM-ELISA. Our strep-SP-IgM-ELISA will be useful for diagnoses in TBE-endemic areas. Copyright © 2018 Elsevier GmbH. All rights reserved.
Katz, David; Shi, Wei; Patrusheva, Irina; Perelygina, Ludmila; Gowda, Manjunath S; Krug, Peter W; Filfili, Chadi N; Ward, John A; Hilliard, Julia K
2012-01-01
B virus (Macacine herpesvirus 1) occurs naturally in macaques and can cause lethal zoonotic infections in humans. Detection of B virus (BV) antibodies in macaques is essential for the development of SPF breeding colonies and for diagnosing infection in macaques that are involved in human exposures. Traditionally, BV infections are monitored for presence of antibodies by ELISA (a screening assay) and western blot analysis (WBA; a confirmatory test). Both tests use lysates of infected cells as antigens. Because WBA often fails to confirm the presence of low-titer serum antibodies detected by ELISA, we examined a recombinant-based ELISA as a potential alternative confirmatory test. We compared a high-throughput ELISA using 384-well plates for simultaneous antibody screening against 4 BV-related, recombinant proteins with the standard ELISA and WBA. The recombinant ELISA results confirmed more ELISA-positive sera than did WBA. The superiority of the recombinant ELISA over WBA was particularly prominent for sera with low (<500 ELISA units) antibody titers. Among low-titer sera, the relative sensitivity of the recombinant ELISA ranged from 36.7% to 45.0% as compared with 3.3% to 10.0% for WBA. In addition, the screening and confirmatory assays can be run simultaneously, providing results more rapidly. We conclude that the recombinant ELISA is an effective replacement for WBA as a confirmatory assay for the evaluation of macaque serum antibodies to BV. PMID:23561887
Reassessing the Detection of B-Virus–Specific Serum Antibodies
Katz, David; Shi, Wei; Wildes, Martin J; Krug, Peter W; Hilliard, Julia K
2012-01-01
B virus, a natural pathogen of macaques, can cause a fatal zoonotic disease in humans. Serologic screening of macaques by titration ELISA (tELISA, screening test) and by Western blot analysis (WBA, confirmatory test) is one of the principle measures to prevent human infection. Here we slightly modified these 2 tests and reevaluated their correlation. We developed a high-throughput tELISA and used it to screen 278 sera simultaneously against the homologous BV antigen and the heterologous antigens of Papiine herpesvirus 2 and Human herpesvirus 1. More sera (35.6%) were positive by the BV-ELISA than by the HVP2-ELISA (21.6%) or HSV1-ELISA (19.8%). The superiority of the homologous tELISA over the heterologous tELISA was prominent in low-titer sera. WBA confirmed only 21% of the tELISA-positive sera with low or intermediate antibody titers. These sera might have contained antibodies to conformational epitopes that could not be detected by WBA, in which denatured antigens are used, but that could be detected by tELISA, which detects both linear and conformational epitopes. WBA confirmed 82% of the tELISA high-titer sera. However, WBA defined the remaining 18% of sera, which were negative by tELISA, as nonnegative. This finding can be attributed to the difficulties encountered with the subjective interpretation of results by WBA. Together, the current results indicate the inadequacy of WBA as a confirmatory assay for sera with low antibody titers. PMID:23561886
Czopowicz, Michał; Szaluś-Jordanow, Olga; Mickiewicz, Marcin; Moroz, Agata; Witkowski, Lucjan; Markowska-Daniel, Iwona; Bagnicka, Emilia; Kaba, Jarosław
2017-09-01
The study was conducted to evaluate influence of the true within-herd prevalence of small ruminant lentivirus (SRLV) infection on agreement beyond chance between three different types of commercial serological ELISAs. Blood samples were collected from 865 goats from 12 dairy goat herds. Serum samples were tested using three commercial ELISA kits: whole-virus indirect ELISA (wELISA), indirect ELISA based on recombined TM and CA antigens (TM/CA-ELISA), and competitive-inhibition ELISA based on SU antigen (SU-ELISA). Herds were classed into three prevalence strata of high (>50%), moderate (10-50%) and low (<10%) true within-herd prevalence of SRLV infection. The latter was estimated on the basis of results of wELISA adjusted by its sensitivity and specificity. Agreement beyond chance between the three ELISAs was assessed at two levels. First, the general agreement was determined using two coefficients corrected for chance-agreement: Cohen's kappa and Gwet's AC 1 . Then, agreement between tests was evaluated using Gwet's AC 1 separately in the three prevalence strata and compared between them by computing 95% confidence intervals for differences with a Bonferroni correction for multiple comparisons. The general agreement between the three tests was very good: wELISA and TM/CA-ELISA - Cohen's kappa of 81.8% (CI 95%: 77.9% to 85.7%), Gwet's AC 1 of 82.7% (CI 95%: 79.0% to 86.4%); wELISA and SU-ELISA - Cohen's kappa of 83.2% (CI 95%: 79.4% to 86.9%), Gwet's AC 1 of 83.9% (CI 95%: 80.4% to 87.5%); TM/CA-ELISA and SU-ELISA - Cohen's kappa of 86.0% (CI 95%: 82.6% to 89.5%), Gwet's AC 1 of 86.9% (CI 95%: 83.6% to 90.1%). However, agreement between ELISAs was significantly related to the within-herd true prevalence - it was significantly lower (although still high) when within-herd true prevalence was moderate (Gwet's AC 1 between 67.2% and 78.7%), whereas remained very high, when true within-herd prevalence was either >50% (Gwet's AC 1 between 91.9% and 98.8%) or <10% (Gwet's AC 1 between 94.7% and 98.4%). Concluding, the three different commercial ELISAs for SRLV infection in goats available on the market yield highly consistent results. However, their agreement is affected by the true within-herd prevalence in a tested population, and the worse (although still high) agreement should be expected, when the percentage of infected goats is moderate. Copyright © 2017 Elsevier B.V. All rights reserved.
van Hoeven, Karen H.; Dale, Connie; Foster, Phil; Body, Barbara
2008-01-01
Accurate determination of the concentrations of immunoglobulin G (IgG) antibody to tetanus toxoid is important in order to evaluate the immunogenicity of tetanus toxoid vaccines, determine immune competence in individual patients, and measure the prevalence of immunity in populations. The performance of three commercially available enzyme-linked immunosorbent assays (ELISAs) for IgG antibodies to tetanus toxoid were evaluated. Serially diluted NIBSC 76/589 and TE-3 human tetanus IgG immunoglobulin international reference standards were analyzed in quadruplicate using ELISAs manufactured by The Binding Site, Inc. (VaccZyme); Scimedx; and Euroimmun. In addition, IgG antibodies to tetanus toxoid were measured in 83 deidentified serum specimens using each manufacturer's ELISA. Each ELISA provided linear results when evaluated with the reference preparations. The Binding Site ELISA provided results that closely corresponded to the reference preparations (y = 1.09x − 0.08), whereas the Scimedx ELISA gave results that were consistently lower (y = 0.21x − 0.07) and the Euroimmun ELISA gave results that were consistently higher (y = 1.5x + 0.30) than the reference preparation concentrations. Using the recommended cutoff for each ELISA (<0.10 IU/ml), the overall agreement of all of the ELISA methods was 78%. Three of eighty-three (3.6%) human serum samples demonstrated inadequate immunity with all three assays. The Binding Site ELISA yielded nonprotective antibody concentrations in only these 3 samples, whereas 19 samples (22.9%) according to the Scimedx ELISA and 6 samples (7.2%) according to the Euroimmun ELISA demonstrated nonprotective concentrations. The performance characteristics of ELISAs for tetanus immunoglobulin titers were manufacturer dependent, and the differences translated into important disparities in reported results. PMID:18845832
Zhao, Hongwei; Nan, Tiegui; Tan, Guiyu; Gao, Wei; Cao, Zhen; Sun, Shuo; Li, Zhaohu; Li, Qing X; Wang, Baomin
2011-09-19
Availability of highly sensitive assays for metal ions can help monitor and manage the environmental and food contamination. In the present study, a monoclonal antibody against Copper(II)-ethylenediaminetetraacetic acid was used to develop two sensitive ELISAs for Cu(II) analysis. Cobalt(II)-EDTA-BSA was the coating antigen in a heterologous indirect competitive ELISA (hicELISA), whereas Co(II)-EDTA-BSA-horseradish peroxidase (HRP) was the enzyme tracer in a heterologous direct competitive ELISA (hdcELISA). Both ELISAs were validated for detecting the content of Cu(II) in environmental waters. The ELISA data agreed well with those from graphite furnace atomic absorption spectroscopy. The methods of developing the Cu(II) hicELISA and hdcELISA are potentially applicable for developing ELISAs for other metals. The chelator-protein complexes such as EDTA-BSA and EDTA-BSA-HRP can form a suite of metal complexes having the consistent hapten density, location and orientation on the conjugates except the difference of the metal core, which can be used as ideal reagents to investigate the relationship between assay sensitivity and antibody affinities for the haptens and the analytes. The strategy of conjugating a haptenated protein directly with HRP can reduce the loss of HRP activity during the conjugation reaction and thus can be applicable for the development of ELISAs for small molecules. Copyright © 2011. Published by Elsevier B.V.
Sharma, Neekun; Hotta, Akitoyo; Yamamoto, Yoshie; Fujita, Osamu; Uda, Akihiko; Morikawa, Shigeru; Yamada, Akio
2013-01-01
A novel competitive enzyme-linked immunosorbent assay (cELISA) was developed and evaluated for detection of antibodies against Francisella tularensis in humans. The assay is based on the ability of serum antibodies to inhibit the binding of monoclonal antibodies (MAbs) directed against F. tularensis lipopolysaccharide antigens. The assay was evaluated using serum samples of tularemia patients, inactivated F. tularensis-immunized rabbits, and F. tularensis-infected mice. Antibodies against F. tularensis were successfully detected in serum samples of tularemia patients as well as the immunized and infected animals. The cELISA method was compared to indirect ELISA (iELISA) and the commonly used microagglutination test (MA) using serum samples of 19 tularemia patients and 50 healthy individuals. The sensitivity and specificity of cELISA were 93.9 and 96.1%, respectively, in comparison to the iELISA. MA was less sensitive than cELISA with a sensitivity and specificity of only 81.8 and 98.0%, respectively. A high degree of correlation (R2 = 0.8226) was observed between cELISA and iELISA results. The novel cELISA developed in this study appears to be highly sensitive and specific for serodiagnosis of human tularemia. The potential of the MAb-based cELISA to be used in both human and animal samples emphasizes its usefulness for serological survey of tularemia among multiple animal species. PMID:23114700
Agreement between commercial assays for haptoglobin and serum amyloid A in goats.
Czopowicz, Michał; Szaluś-Jordanow, Olga; Mickiewicz, Marcin; Moroz, Agata; Witkowski, Lucjan; Markowska-Daniel, Iwona; Reczyńska, Daria; Bagnicka, Emilia; Kaba, Jarosław
2017-10-02
Haptoglobin (Hp) and serum amyloid A (SAA) are considered as the major acute phase proteins (APPs) in goats. These APPs have been investigated in several studies during the last decade. In most studies, a colorimetric assay for Hp and a solid phase sandwich ELISA for SAA have been used for quantification. In 2015, reference intervals for APPs were determined using a new type of assay, the competitive ELISA (cELISA). Results obtained by the cELISA differed significantly from results obtained by previously used assays. The present study aimed to assess the agreement between so far used assays and cELISAs. Sera of 152 female dairy goats of two Polish national breeds were analysed. The concentration of Hp was determined using a colorimetric assay (Hp-CA) and the cELISA (Hp-cELISA), while a solid phase sandwich ELISA (SAA-sELISA) and the cELISA (SAA-cELISA) were used to measure SAA. Agreement between test results was assessed by preparing Bland-Altman plots, and analyzing 95% limits of agreement (LoA). Finally, the assays for Hp and SAA were compared using 147 and 138 serum samples, respectively, as 5 and 14 paired measurements, respectively, were excluded from agreement analyses to avoid extrapolation of Hp and SAA concentration. Measurements obtained by the Hp-CA and Hp-cELISA showed weak positive correlation (r = 0.24, P = 0.003). Limits of agreement (LoA) ranged from + 1.6 (95% CI 1.4 to 1.8) g/L to - 1.5 (95% CI - 1.7 to - 1.3) g/L. Measurements yielded by the SAA-sELISA and SAA-cELISA did not correlate (r = - 0.01, P = 0.855). LoA ranged from + 14.5 mg/L (95% CI 12.9 to 16.1) to - 8.5 mg/L (95% CI - 10.1 to - 6.9). Agreement between the two types of commercial assays for determination of Hp and SAA concentrations in goats is poor and cELISAs tend to underrate both Hp and SAA concentrations.
Scoles, Glen A; Goff, Will L; Lysyk, Timothy J; Lewis, Gregory S; Knowles, Donald P
2008-07-27
A commercially available (cELISA) kit for diagnosing Anaplasma marginale infection in cattle was validated for diagnosing A ovis infection in sheep using the bovine serum controls as supplied by the manufacturer (BcELISA) and sheep serum controls from pathogen-free sheep (OcELISA). True positives were identified using two previously established assays, a nested PCR (nPCR) test and an indirect immunofluorescent assay (IFA). The BcELISA was also applied to sera from various species of wild ruminants, comparing the results with the IFA. Receiver operating characteristic (ROC) analysis indicated that the predicted threshold inhibition for the BcELISA was 19.2. The sensitivity for the BcELISA was 98.2% and the specificity was 96.3%. The predicted threshold inhibition decreased to 14.3 for the OcELISA; the sensitivity was 96.5% and the specificity was 98.1%. There was >/=90% concordance between IFA and nPCR, as well as between the BcELISA at 19% inhibition cutoff and either IFA or PCR. Concordance between the cELISA and IFA using sera from elk, mule deer, bighorn sheep, pronghorn antelope, and black-tailed deer ranged from 64% to 100%. This commercially available cELISA test kit can be used very effectively to test domestic sheep for infection with A. ovis using the kit-supplied controls (i.e. the BcELISA) and a 19% inhibition cutoff; the kit may also be useful for detecting intra-erythrocytic Anaplasma infections in wild ruminants.
Sandwich-dot enzyme-linked immunosorbent assay for the detection of canine distemper virus
Li, Zhi; Zhang, Yanlong; Wang, Huiguo; Jin, Jinhua; Li, Wenzhe
2013-01-01
A sandwich-dot enzyme-linked immunosorbent assay (dot ELISA) was developed for the detection of canine distemper virus (CDV). In 56 dogs suspected to have CD the rates of detection of CDV antigen in samples of blood lymphocytes and palpebral conjunctiva by dot ELISA and ELISA were, respectively, 91% (49/54) and 81% (44/54) for the lymphocyte samples and 88% (28/32) and 75% (24/32) for the conjunctival samples. The CDV detection limits were 10 ng/50 μL for dot ELISA and 40 ng/50 μL for ELISA. The reliability of dot ELISA relative to electron microscopy was 96% with 22 samples: all 21 samples in which CDV particles were observed by electron microscopy yielded positive results with dot ELISA; the single sample in which particles were not observed yielded false-positive results with dot ELISA. The results indicate that the dot ELISA developed can serve as a reliable rapid diagnostic test in suspected cases of CD and also be useful for epidemiologic surveillance of the disease. PMID:24124274
Mason, Kathleen L; Gonzalez, Michael V; Chung, Chungwon; Mousel, Michelle R; White, Stephen N; Taylor, Joshua B; Scoles, Glen A
2017-09-01
An accurate and simple-to-perform new version of a competitive ELISA (cELISA) kit that became commercially available in 2015 for testing of cattle for antibody to Anaplasma marginale was validated for detection of Anaplasma ovis antibody in domestic sheep. True positives and negatives were identified using nested PCR (nPCR) as the gold standard. Negative bovine control sera supplied with the kit were used to calculate % inhibition (%I), designated bovine control ELISA (BcELISA), and this was compared to %I calculated from negative ovine sera derived from hand-raised, pathogen-free sheep, designated ovine control ELISA (OcELISA). The receiver operating characteristics area under the curve was 1.0 with a p value <0.001 regardless of the source of the control sera. The cutoff values for negative BcELISA and OcELISA were <30%I and <27%I, respectively. Our work confirmed that this Anaplasma antibody cELISA kit version 2 can be used with the serum controls supplied in the kit to test for A. ovis antibody in domestic sheep. Furthermore, this work confirmed the historically high infection prevalence (>93%) at the U.S. Sheep Experiment Station (Dubois, Idaho), in spite of efforts to reduce the possibility for iatrogenic transmission there, suggesting high levels of tick-borne transmission.
Sensitive detection of Escherichia coli O157:H7 based on cascade signal amplification in ELISA.
Shan, Shan; Liu, Daofeng; Guo, Qi; Wu, Songsong; Chen, Rui; Luo, Kai; Hu, Liming; Xiong, Yonghua; Lai, Weihua
2016-09-01
In this study, cascade signal amplification in ELISA involving double-antibody sandwich ELISA and indirectly competitive ELISA was established to sensitively detect Escherichia coli O157:H7. In the double-antibody sandwich ELISA, a complex was formed comprising anti-E. coli O157:H7 polyclonal antibody, E. coli O157:H7, biotinylated anti-E. coli O157:H7 monoclonal antibody, streptavidin, and biotinylated β-lactamase. Penicillin solution was then added into the ELISA well and hydrolyzed by β-lactamase. Afterward, the penicillin solution was transferred to indirectly competitive ELISA. The concentration of penicillin can be sensitively detected in indirectly competitive ELISA. In the cascade signal amplification system, increasing the amount of added E. coli O157:H7 resulted in more β-lactamase and less penicillin. The detection sensitivity of E. coli O157:H7, which was 20cfu/mL with the cascade signal amplification in ELISA, was 1,000-fold higher than that of traditional ELISA. Furthermore, the novel method can be used to detect E. coli O157:H7 in milk (2cfu/g). Therefore, this new signaling strategy will facilitate analyses of highly sensitive foodborne pathogens. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Lee, Eui Hyung; Kim, Yeon Hee; Kim, Sinyoung; Kim, Song-ee
2012-01-01
Background Bullous pemphigoid (BP) is an autoimmune subepidermal bullous disease associated with autoantibodies against BP180 and BP230. Enzyme-linked immunosorbent assay (ELISA) is a sensitive tool for the detection of immunoglobulin G (IgG) anti-BP180 and anti-BP230 autoantibodies. Objective The aim of this study was to evaluate the usefulness of ELISA for diagnosing and monitoring the disease activity of BP. Methods We evaluated serum IgG levels of anti-BP180 and anti-BP230 autoantibodies in 47 BP patients, 16 epidermolysis bullosa aquisita patients, and 15 healthy volunteers using ELISA. Through retrospective review of the medical records, the clinical characteristics of BP including disease activity, duration, pruritus severity and peripheral blood eosinophil counts were assessed. Results The sensitivity of BP180 ELISA was 97.9%, BP230 ELISA 72.3%, and a combination of the two was 100%. The specificity of BP180 ELISA was 90.3%, BP230 ELISA 100%, and a combination of the two was 90.3%. BP180 ELISA scores showed strong associations with disease activity, pruritus severity, peripheral blood eosinophil counts, and disease duration, whereas BP230 ELISA scores did not. Conclusion BP180 and BP230 ELISAs are highly sensitive methods for the diagnosis of BP, and BP180 ELISA, in particular, is a sensitive tool for monitoring the disease activity of BP. PMID:22363155
Erickson, J Alan; Grenache, David G
2016-01-15
Routine testing for chromogranin A (CgA) using an established commercial ELISA revealed an apparent high-dose hook effect in approximately 15% of specimens. Investigations found the same effect in two additional ELISAs. We hypothesized that a CgA derived peptide(s) at high concentrations was responsible but experiments were inconclusive. Here we describe the analytical performance characteristics of the Chromoa™ CgA ELISA that did not display the apparent high-dose hook effect. Performance characteristics of the Chromoa ELISA were assessed. The reference interval was established utilizing healthy volunteers. Specimens producing the apparent high-dose hook effect in other assays were evaluated using the Chromoa ELISA. The limit of detection was 8ng/ml. Linearity was acceptable (slope=1.04, intercept=18.1 and r(2)=0.997). CVs were ≤4.6 and ≤9.3% for repeatability and within-laboratory imprecision, respectively. CgA was stable at ambient and refrigerated temperatures for a minimum of two and 14days, respectively. An upper reference interval limit of 95ng/ml was established. Specimens demonstrating the apparent high-dose hook effect in other ELISAs did not exhibit the phenomenon using the Chromoa ELISA. The Chromoa ELISA demonstrates acceptable performance for quantifying serum CgA. The apparent high-dose hook effect exhibited in other ELISAs was absent using the Chromoa assay. Copyright © 2015 Elsevier B.V. All rights reserved.
A Novel Blocking ELISA for Detection of Antibodies against Hepatitis E Virus in Domestic Pigs.
Chen, Yiyang; Zhao, Qin; Liu, Baoyuan; Wang, Lizhen; Sun, Yani; Li, Huixia; Wang, Xinjie; Syed, Shahid Faraz; Zhang, Gaiping; Zhou, En-Min
2016-01-01
Hepatitis E virus (HEV) infects both humans and animals, with an overall human mortality rate generally less than 1%, but as high as 20% among pregnant women. HEV strains fall into 4 major genotypes. Zoonotic genotypes 3 and 4 associate with sporadic human and animal HEV cases in many industrialized countries. To date, collective evidence implicates pigs as the main HEV reservoir, justifying the importance of monitoring HEV infection rates in pig herds to prevent human illness. Due to the lack of a robust in vitro cell culture system for viral propagation, no "gold standard" assay has yet been developed to detect HEV infection in domestic pigs. 1E4, a monoclonal antibody (mAb) specific for the C-terminal 268 amino acids of HEV genotype 4 ORF2 capsid protein (sORF2-C), was generated and conjugated to horseradish peroxidase (HRP) for use in a blocking ELISA (bELISA). Optimal sORF2-C coating antigen concentration (8 μg/ml), HRP-1E4 dilution (1:1000), and test pig serum dilution (1:20) were determined using a checkerboard titration test. A cut-off value of 16.9% was chosen to differentiate between positive vs. negative sera after mean percent inhibition (PI) testing of 230 negative pig sera. Compared with the indirect ELISA (iELISA), western blot, and a commercial ELISA kit for detecting anti-HEV antibodies in human sera, the bELISA showed no statistical differences and statistically high coincidence of 93.23%, 92%, and 95% with the other tests, respectively. A blocking ELISA (bELISA) for detecting anti-HEV antibodies in pig serum samples was developed with high sensitivity and high specificity comparable to that of the indirect ELISA. The bELISA results exhibited high agreement with iELISA, western blot, and a commercial ELISA kit designed to detect human anti-HEV antibodies. Therefore, bELISA should serve as an ideal method for large-scale serological investigation of anti-HEV antibodies in domestic pigs.
Familial associations with paratuberculosis ELISA results in Texas Longhorn cattle.
Osterstock, Jason B; Fosgate, Geoffrey T; Cohen, Noah D; Derr, James N; Manning, Elizabeth J B; Collins, Michael T; Roussel, Allen J
2008-05-25
The objective of this cross-sectional study was to estimate familial associations with paratuberculosis ELISA status in beef cattle. Texas Longhorn cattle (n=715) greater than 2years of age were sampled for paratuberculosis testing using ELISA and fecal culture. Diagnostic test results were indicative of substantial numbers of false-positive serological reactions consistent with environmental exposure to non-MAP Mycobacterium spp. Associations between ancestors and paratuberculosis ELISA status of offspring were assessed using conditional logistic regression. The association between ELISA status of the dam and her offspring was assessed using linear mixed-effect models. Significant associations were identified between some ancestors and offspring ELISA status. The odds of being classified as "suspect" or greater based on ELISA results were 4.6 times greater for offspring of dams with similarly increased S:P ratios. A significant positive linear association was also observed between dam and offspring log-transformed S:P ratios. Results indicate that there is familial aggregation of paratuberculosis ELISA results in beef cattle and suggest that genetic selection based on paratuberculosis ELISA status may decrease seroprevalence. However, genetic selection may have minimal effect on paratuberculosis control in herds with exposure to non-MAP Mycobacterium spp.
Allergen immunoassays--considerations for use of naturally incurred standards.
Taylor, Steve L; Nordlee, Julie A; Niemann, Lynn M; Lambrecht, Debra M
2009-09-01
The enzyme-linked immunosorbent assay (ELISA) offers many advantages for the detection of potentially hazardous allergenic food residues that might become adventitious components of other foods during the course of food production and processing. ELISAs detect proteins, and food allergens are proteins. ELISAs are sufficiently sensitive and specific for detection of food allergen residues. ELISAs can also be produced in formats that are compatible with the industrial food processing environment. However, ELISAs also have disadvantages that should be carefully evaluated and widely recognized. Various food-processing operations can have profound effects on the detectability of allergenic food residues. ELISAs detect intact proteins but protein hydrolysates evade detection in some ELISA formats. The residual proteins present in some ingredients derived from commonly allergenic sources may also not be easily detected with ELISAs because of the nature of the protein residues remaining, e.g. lipophilic. Processing operations can dramatically lower the solubility of proteins. In some food formulations, heat processing, in particular, induces chemical modifications that can affect antibody binding to epitopes in the ELISA. The use of naturally incurred standards where allergenic food residues are incorporated into various representative food matrices and then processed in a manner similar to "real-world" food processing can reveal some of the limitations of allergen ELISAs. Methods for the preparation of naturally incurred standards in chocolate, cookie, muffin, ice cream, pasta, frankfurter, and cream of potato soup are provided as examples.
Tong, Qing-He; Tao, Tao; Xie, Li-Qi; Lu, Hao-Jie
2016-06-15
Detection of low-abundance proteins and their post-translational modifications (PTMs) remains a great challenge. A conventional enzyme-linked immunosorbent assay (ELISA) is not sensitive enough to detect low-abundance PTMs and suffers from nonspecific detection. Herein, a rapid, highly sensitive and specific platform integrating ELISA with a proximity ligation assay (PLA), termed ELISA-PLA, was developed. Using ELISA-PLA, the specificity was improved by the simultaneous and proximate recognition of targets through multiple probes, and the sensitivity was significantly improved by rolling circle amplification (RCA). For GFP, the limit of detection (LOD) was decreased by two orders of magnitude compared to that of ELISA. Using site-specific phospho-antibody and pan-specific phospho-antibody, ELISA-PLA was successfully applied to quantify the phosphorylation dynamics of ERK1/2 and the overall tyrosine phosphorylation level of ERK1/2, respectively. ELISA-PLA was also used to quantify the O-GlcNAcylation of AKT, c-Fos, CREB and STAT3, which is faster and more sensitive than the conventional immunoprecipitation and western blotting (IP-WB) method. As a result, the sample consumption of ELISA-PLA was reduced 40-fold compared to IP-WB. Therefore, ELISA-PLA could be a promising platform for the rapid, sensitive and specific detection of proteins and PTMs. Copyright © 2016 Elsevier B.V. All rights reserved.
Iddawela, D; Ehambaram, K; Kumarasiri, P V; Wijesundera, S
2015-09-01
ELISA is the most widely used form of diagnosis for toxoplasmosis. Several commercial kits are currently used in Sri Lanka. However, these kits are not affordable in resource-limited settings. Objectives Aim of this study was to develop a cost effective in-house ELISA for the detection of Toxoplasma antibody and to estimate the diagnostic accuracy compared to a commercial kit. Vero cell lines were inoculated with tachyzoites and harvested after 2-6 days and sonicated to obtain somatic antigen. The antigen was used as coating material in ELISA to detect antibodies against T. gondii in patient sera. Hundred and three patients' sera were analysed by in-house ELISA and kit ELISA. Optical density (OD) values were analysed statistically. Toxoplasma IgG avidity test was used to determine the chronic and acute phase of infection. The optimum working dilutions for antigen was 0.846 μg/ml and for serum 1 in 100. The optimal cut-off values for the in-house ELISA within the range 0.85 to 0.98 at which the sensitivity was 95.3% and specificity was 98.3. The OD values of in-house ELISA were compared with OD values of kit ELISA and the results showed strong correlation between the two tests. The results of our study demonstrated that our in-house ELISA for detection of T. gondii antibody was as sensitive and specific as the commercial kit used in this study. Thus, the in-house ELISA is a useful, costeffective tool for diagnostic and screening purposes.
Meza-Lucas, Antonio; Pérez-Villagómez, María-Fernanda; Martínez-López, José-Patricio; García-Rodea, Ricardo; Martínez-Castelán, María-Guadalupe; Escobar-Gutiérrez, Alejandro; de-la-Rosa-Arana, Jorge-Luis; Villanueva-Zamudio, Altagracia
2016-09-01
A comparison of DOT-ELISA and Standard-ELISA was made for detection of Vibrio cholerae toxin in culture supernatants of bacteria isolated from human and environmental samples. A total of 293 supernatants were tested in a double blind assay. A correlation of 100 % was obtained between both techniques. The cholera toxin was found in 20 Inaba and 3 Ogawa strains. Positive samples were from seafood (17 samples), potable water (1 sample) and sewage (5 samples). The DOT-ELISA was useful as the standard-ELISA to confirm the presence of cholera toxin in the environmental samples.
Figueroa-Santiago, Olgary; Delgado, Bonnibel; Espino, Ana M.
2011-01-01
An indirect enzyme-linked immunosorbent assay (ELISA) was developed and evaluated for its diagnostic ability to detect human IgG antibodies against Fasciola hepatica saposin-like protein-2. The assay was compared with an indirect ELISA with excretory-secretory products (FhES) from adult F. hepatica. In an analysis of the sera of 37 patients infected with F. hepatica, 40 patients with other parasitic infections, and 50 healthy controls, the sensitivity of both ELISA assays was 100%. However, the FhSAP2-based ELISA was more specific (95.6%) than the FhES-ELISA (91.9%). These results demonstrated that FhSAP2 can be used in the serodiagnosis of chronic human fascioliasis with additional advantage that is relative cheap and easy to produce. Studies are in progress to evaluate this FhSAP2-ELISA assay in a large-scale prevalence surveys in endemic areas. PMID:21683266
Enzyme-linked immunosorbent assay for detection of antibodies to Epstein-Barr virus antigens.
Voevodin, A F; Pácsa, A S
1983-01-01
Enzyme-Linked Immunosorbent Assay (ELISA) was standardized for measurement of antibody activity of reference human and baboon (Papio hamadryas) sera to soluble Epstein-Barr virus (EBV) antigens. A comparison with the immunofluorescent (IF) method showed that ELISA detects antibody specifically and sensitivity. In ELISA, Herpesvirus Papio (HVP) nuclear antigen (HUPNA) positive baboon serum reacted with EBV nuclear antigen (EBNA), as a further indication of the antigenic similarity between HVP and EBV. Forty-two baboon sera were tested with EBV antigens in both ELISA and IF test. The results showed an agreement between the two methods and also that by the use of EBV antigens, ELISA measures anti-HVP activity of baboon sera. ELISA did not reveal significant difference in antibody activity of 23 baboons with lymphoma and that of 24 healthy baboons. Results provide further data that ELISA can be used effectively in the field of EBV serology.
75 FR 57200 - National Poultry Improvement Plan and Auxiliary Provisions
Federal Register 2010, 2011, 2012, 2013, 2014
2010-09-20
... (ELISA) test to confirm the positive results of other serological tests. We are proposing to remove the ELISA test from this list. The ELISA test is a screening assay and should not be used to confirm... status is negative for Mycoplasma. We would amend this paragraph to include the ELISA and the official...
Lauricella, Marta Alicia; Maidana, Cristina Graciela; Frias, Victoria Fragueiro; Romagosa, Carlo M.; Negri, Vanesa; Benedetti, Ruben; Sinagra, Angel J.; Luna, Concepcion; Tartaglino, Lilian; Laucella, Susana; Reed, Steven G.; Riarte, Adelina R.
2016-01-01
Direct observation of Leishmania parasites in tissue aspirates has shown low sensitivity for the detection of canine visceral leishmaniasis (VL). Therefore in the last quarter century immunoenzymatic tests have been developed to improve diagnosis. The purpose of this study was to develop a fast recombinant K28 antigen, naked-eye qualitative enzyme-linked immunosorbent assay (VL Ql-ELISA) and a quantitative version (VL Qt-ELISA), and to display it in a kit format, whose cutoff value (0.156) was selected as the most adequate one to differentiate reactive from nonreactive samples. Considering 167 cases and 300 controls, sensitivity was 91% for both assays and specificity was 100% and 98.7% in Ql-ELISA and Qt-ELISA, respectively. Positive predictive values were 100% and 97.4% for Ql-ELISA and Qt-ELISA, respectively, and negative predictive values were 95.2% for both ELISAs. Reagent stability, reliability studies, including periodic repetitions and retest of samples, cutoff selection, and comparison of rK28 ELISAs with rK39 immunochromatographic test, were the international criteria that supported the quality in both kits. The performance of both ELISA kits in this work confirmed their validity and emphasized their usefulness for low-to-medium complexity laboratories. PMID:27162270
Reiter-Owona, Ingrid; Grüner, Beate; Frosch, Matthias; Hoerauf, Achim; Kern, Peter; Tappe, Dennis
2009-01-01
Sera of 50 patients with either cystic (CE) or alveolar echinococcosis (AE) in different clinical stages were examined for the presence of anti-Echinococcus-antibodies. Antibody-screening was performed with ELISA, IHA and IFAT, and confirmatory testing was done by the commercialized E. multilocularis-specific Em2plus-ELISA versus an in-house E. multilocularis-specific Em10-ELISA. Sera with discrepant confirmatory results were subjected to a commercial Echinococcus IgG Western blot (WB). In sera from patients with CE, the Em2plus-ELISA showed cross-reactions in 23.5%, whereas the Em10-ELISA did not exhibit any cross-reactivity. Cross-reactivity paralleled active infection with high antibody titers in the screening assays. In sera from patients with AE, confirmation by both ELISAs was achieved in 57.6%, mostly in patients with an advanced stage of the disease and high antibody titers in the screening assays. False-negative reactions of both ELISAs occurred in 30.3%, mostly in patients who had low antibody levels in the screening tests. The Em2plus-ELISA exhibited fewer false-negative reactions than the Em10-ELISA. The WB confirmed the positive results of either assay and was the assay with the highest reliability at different stages of CE and AE, followed by the Em2plus-ELISA for AE. High antibody titers in the screening assays will favour the detection of species-specific antibodies in either form.
Liu, Dan; Li, Xingrui; Zhou, Junkai; Liu, Shibo; Tian, Tian; Song, Yanling; Zhu, Zhi; Zhou, Leiji; Ji, Tianhai; Yang, Chaoyong
2017-10-15
Enzyme-linked immunosorbent assay (ELISA) is a popular laboratory technique for detection of disease-specific protein biomarkers with high specificity and sensitivity. However, ELISA requires labor-intensive and time-consuming procedures with skilled operators and spectroscopic instrumentation. Simplification of the procedures and miniaturization of the devices are crucial for ELISA-based point-of-care (POC) testing in resource-limited settings. Here, we present a fully integrated, instrument-free, low-cost and portable POC platform which integrates the process of ELISA and the distance readout into a single microfluidic chip. Based on manipulation using a permanent magnet, the process is initiated by moving magnetic beads with capture antibody through different aqueous phases containing ELISA reagents to form bead/antibody/antigen/antibody sandwich structure, and finally converts the molecular recognition signal into a highly sensitive distance readout for visual quantitative bioanalysis. Without additional equipment and complicated operations, our integrated ELISA-Chip with distance readout allows ultrasensitive quantitation of disease biomarkers within 2h. The ELISA-Chip method also showed high specificity, good precision and great accuracy. Furthermore, the ELISA-Chip system is highly applicable as a sandwich-based platform for the detection of a variety of protein biomarkers. With the advantages of visual analysis, easy operation, high sensitivity, and low cost, the integrated sample-in-answer-out ELISA-Chip with distance readout shows great potential for quantitative POCT in resource-limited settings. Copyright © 2017. Published by Elsevier B.V.
Interpreting dual ELISA and qPCR data for bacterial kidney disease of salmonids.
Nance, Shelly L; Riederer, Michael; Zubkowski, Tyler; Trudel, Marc; Rhodes, Linda D
2010-09-02
Although there are a variety of methods available for the detection of Renibacterium salmoninarum, the causative agent of bacterial kidney disease in salmon and trout, the enzyme-linked immunosorbent assay (ELISA) is probably the most widely used method. However, ELISA measures bacterial antigen, which does not necessarily reflect the number of cells present. We hypothesized that dual analysis of kidney tissue by ELISA and a quantitative real-time polymerase chain reaction assay (qPCR) would provide complementary information about antigen level and the number of bacterial genomes. We found that DNA extracted from the insoluble fraction of the ELISA tissue preparation produced the same qPCR result as DNA extracted directly from frozen tissue, permitting true dual analysis of the same tissue sample. We examined kidney tissue in this manner from individual free-ranging juvenile Chinook salmon and antibiotic-treated captive subadult Chinook salmon and observed 3 different patterns of results. Among the majority of fish, there was a strong correlation between the ELISA value and the qPCR value. However, subsets of fish exhibited either low ELISA values with elevated qPCR values or higher ELISA values with very low qPCR values. These observations suggest a conceptual model that allows inferences about the state of infection of individual fish based on dual ELISA/qPCR results. Although this model requires further assessment through experimental infections and treatments, it may have utility in broodstock selection programs that currently apply egg-culling practices based on ELISA alone.
Enzyme-linked immunosorbent assay for Potomac horse fever disease.
Pretzman, C I; Rikihisa, Y; Ralph, D; Gordon, J C; Bech-Nielsen, S
1987-01-01
An enzyme-linked immunosorbent assay (ELISA) for immunoglobulin G (IgG) and IgM in natural and experimental infections of equids with Ehrlichia risticii was developed. Ehrlichial organisms purified from an infected mouse macrophage cell line were used as the antigen. IgM was separated from serum IgG by the expedient of spun-column chromatography, allowing the use of an indirect ELISA for quantitation of both IgG and IgM in the test sera. Among 16 paired sera from horses exhibiting clinical signs of Potomac horse fever, 8 were positive by the indirect fluorescent-antibody test (IFA), 11 were positive by the IgG ELISA, and 8 were positive by the IgM ELISA. All IFA-positive specimens were positive by the IgG ELISA, which appeared to be more sensitive than the IFA. In all cases, the IgG ELISA alone would have sufficed for diagnosis when acute- and convalescent-phase sera were available. When 26 single acute- or convalescent-phase serum samples were tested, the IFA detected 8, the IgG ELISA detected 10, and the IgM ELISA detected 6 positive serum specimens. The kinetics of IgG and IgM responses as determined by ELISA in two experimentally infected ponies which survived infection and challenges revealed that specific IgM was short-lived, falling to undetectable levels by day 60 postinoculation, whereas specific IgG persisted for more than 1 year. IgM and IgG were detected as early as days 1 and 10, respectively, postinoculation. The results suggest that the ELISA is more sensitive than the IFA and that the IgM ELISA may provide a means for early diagnosis of Potomac horse fever at or before the onset of clinical signs.
Bueno, Ednéia C.; Snege, Miriam; Vaz, Adelaide J.; Leser, Paulo G.
2001-01-01
Neurocysticercosis (NC), caused by the presence of Taenia solium metacestodes in tissues, is a severe parasitic infection of the central nervous system with universal distribution. To determine the efficiency of enzyme-linked immunosorbent assay (ELISA) and immunoblot with antigens of T. crassiceps vesicular fluid (Tcra) compared to standard techniques (indirect immunofluorescence test [IFT] and complement fixation test [CFT]) using T. solium cysticerci (Tso) for the serodiagnosis of NC, we studied serum samples from 24 patients with NC, 30 supposedly healthy individuals, 76 blood bank donors, 45 individuals with other non-NC parasitoses, and 97 samples from individuals screened for cysticercosis serology (SC). The sensitivity observed was 100% for ELISA-Tso and ELISA-Tcra, 91.7% for the IFT, and 87.5% for the CFT. The specificity was 90% for ELISA-Tso, 96.7% for ELISA-Tcra, 50% for IFT, and 63.3% for CFT. The efficiency was highest for ELISA-Tcra, followed by ELISA-Tso, IFT, and CFT. Of the 23 samples from SC group, which were reactive to ELISA-Tso and/or ELISA-Tcra, only 3 were positive to immunblot-Tcra (specific peptides of 14- and 18-kDa) and to glycoprotein peptides purified from Tcra antigen (gp-Tcra), showing the low predictive value of ELISA for screening. None of the samples from the remaining groups showed specific reactivity in immunoblot-Tcra. These results demonstrate that ELISA-Tcra can be used as a screening method for the serodiagnosis of NC and support the need for specific tests for confirmation of the results. The immunoblot can be used as a confirmatory test both with Tcra and gp-Tcra, with the latter having an advantage in terms of visualization of the results. PMID:11687454
Kunita, Satoshi; Chaya, Miyuki; Hagiwara, Kozue; Ishida, Tomoko; Takakura, Akira; Sugimoto, Tatsuya; Iseki, Hiroyoshi; Fuke, Kumiko; Sugiyama, Fumihiro; Yagami, Ken-ichi
2006-04-01
Nucleotide sequences of mouse parvovirus (MPV) isolate, named MPV/UT, and mouse minute virus (MMV) were analyzed and used for expressing recombinant proteins in E. coli. ELISA tests using recombinant major capsid protein (rVP2) and recombinant major non-structural protein (rNS1) as antigens were developed and their performance in serologic detection of rodent parvovirus infection was assessed. MPV-rVP2 and MMV-rVP2 ELISAs reacted specifically with anti-MPV and anti-MMV mouse sera, respectively. MMV-rNS1 antigen had a wide reaction range with antisera to rodent parvoviruses including MPV, MMV, Kilham rat virus (KRV) and H-1 virus. All mice oronasally infected with MPV were seropositive at 4 weeks post-infection in screening by ELISAs using MPV-rVP2 and MMV-rNS1 antigens, but were negative by conventional ELISA using whole MMV antigen. A contact transmission experiment revealed that transmission of MPV occurred up to 4 weeks post-infection, and all cage mates were seropositive in screening with MPV-rVP2 and MMV-rNS1 ELISAs. These results indicate that MPV-rVP2 and MMV-rVP2 are specific ELISA antigens which distinguish between MPV and MVM infection, while MMV-rNS1 antigen can be used in generic ELISA for a variety of rodent parvoviruses. The higher sensitivity of MPV-rVP2 ELISA than conventional ELISA for detecting seroconversion to MPV in oronasally infected mice as well as in cage mates suggests the usefulness of MPV-rVP2 ELISA in quarantine and microbiological monitoring of MPV infection in laboratory mice.
An ELISA Lab-on-a-Chip (ELISA-LOC).
Rasooly, Avraham; Bruck, Hugh A; Kostov, Yordan
2013-01-01
Laminated object manufacturing (LOM) technology using polymer sheets is an easy and affordable method for rapid prototyping of Lab-on-a-Chip (LOC) systems. It has recently been used to fabricate a miniature 96 sample ELISA lab-on-a-chip (ELISA-LOC) by integrating the washing step directly into an ELISA plate. LOM has been shown to be capable of creating complex 3D microfluidics through the assembly of a stack of polymer sheets with features generated by laser micromachining and by bonding the sheets together with adhesive. A six layer ELISA-LOC was fabricated with an acrylic (poly(methyl methacrylate) (PMMA)) core and five polycarbonate layers micromachined by a CO(2) laser with simple microfluidic features including a miniature 96-well sample plate. Immunological assays can be carried out in several configurations (1 × 96 wells, 2 × 48 wells, or 4 × 24 wells). The system includes three main functional elements: (1) a reagent loading fluidics module, (2) an assay and detection wells plate, and (3) a reagent removal fluidics module. The ELISA-LOC system combines several biosensing elements: (1) carbon nanotube (CNT) technology to enhance primary antibody immobilization, (2) sensitive ECL (electrochemiluminescence) detection, and (3) a charge-coupled device (CCD) detector for measuring the light signal generated by ECL. Using a sandwich ELISA assay, the system detected Staphylococcal enterotoxin B (SEB) at concentrations as low as 0.1 ng/ml, a detection level similar to that reported for conventional ELISA. ELISA-LOC can be operated by a syringe and does not require power for operation. This simple point-of-care (POC) system is useful for carrying out various immunological assays and other complex medical assays without the laboratory required for conventional ELISA, and therefore may be more useful for global healthcare delivery.
Measuring Hordein (Gluten) in Beer – A Comparison of ELISA and Mass Spectrometry
Blundell, Malcolm J.; Goswami, Hareshwar P.; Howitt, Crispin A.
2013-01-01
Background Subjects suffering from coeliac disease, gluten allergy/intolerance must adopt a lifelong avoidance of gluten. Beer contains trace levels of hordeins (gluten) which are too high to be safely consumed by most coeliacs. Accurate measurement of trace hordeins by ELISA is problematic. Methods We have compared hordein levels in sixty beers, by sandwich ELISA, with the level determined using multiple reaction monitoring mass spectrometry (MRM-MS). Results Hordein levels measured by ELISA varied by four orders of magnitude, from zero (for known gluten-free beers) to 47,000 µg/mL (ppm; for a wheat-based beer). Half the commercial gluten-free beers were free of hordein by MS and ELISA. Two gluten-free and two low-gluten beers had zero ELISA readings, but contained significant hordein levels (p<0.05), or near average (60–140%) hordein levels, by MS, respectively. Six beers gave false negatives, with zero ELISA readings but near average hordein content by MS. Approximately 20% of commercial beers had ELISA readings less than 1 ppm, but a near average hordein content by MS. Several barley beers also contained undeclared wheat proteins. Conclusions ELISA results did not correlate with the relative content of hordein peptides determined by MS, with all barley based beers containing hordein. We suggest that mass spectrometry is more reliable than ELISA, as ELISA enumerates only the concentration of particular amino-acid epitopes; this may vary between different hordeins and may not be related to the absolute hordein concentration. MS quantification is undertaken using peptides that are specific and unique, enabling the quantification of individual hordein isoforms. This outlines the problem of relying solely on ELISA determination of gluten in beverages such as beer and highlights the need for the development of new sensitive and selective quantitative assay such as MS. PMID:23509606
2011-01-01
Background The entomological inoculation rate (EIR) is an important indicator in estimating malaria transmission and the impact of vector control. To assess the EIR, the enzyme-linked immunosorbent assay (ELISA) to detect the circumsporozoite protein (CSP) is increasingly used. However, several studies have reported false positive results in this ELISA. The false positive results could lead to an overestimation of the EIR. The aim of present study was to estimate the level of false positivity among different anopheline species in Cambodia and Vietnam and to check for the presence of other parasites that might interact with the anti-CSP monoclonal antibodies. Methods Mosquitoes collected in Cambodia and Vietnam were identified and tested for the presence of sporozoites in head and thorax by using CSP-ELISA. ELISA positive samples were confirmed by a Plasmodium specific PCR. False positive mosquitoes were checked by PCR for the presence of parasites belonging to the Haemosporidia, Trypanosomatidae, Piroplasmida, and Haemogregarines. The heat-stability and the presence of the cross-reacting antigen in the abdomen of the mosquitoes were also checked. Results Specimens (N = 16,160) of seven anopheline species were tested by CSP-ELISA for Plasmodium falciparum and Plasmodium vivax (Pv210 and Pv247). Two new vector species were identified for the region: Anopheles pampanai (P. vivax) and Anopheles barbirostris (Plasmodium malariae). In 88% (155/176) of the mosquitoes found positive with the P. falciparum CSP-ELISA, the presence of Plasmodium sporozoites could not be confirmed by PCR. This percentage was much lower (28% or 5/18) for P. vivax CSP-ELISAs. False positive CSP-ELISA results were associated with zoophilic mosquito species. None of the targeted parasites could be detected in these CSP-ELISA false positive mosquitoes. The ELISA reacting antigen of P. falciparum was heat-stable in CSP-ELISA true positive specimens, but not in the false positives. The heat-unstable cross-reacting antigen is mainly present in head and thorax and almost absent in the abdomens (4 out of 147) of the false positive specimens. Conclusion The CSP-ELISA can considerably overestimate the EIR, particularly for P. falciparum and for zoophilic species. The heat-unstable cross-reacting antigen in false positives remains unknown. Therefore it is highly recommended to confirm all positive CSP-ELISA results, either by re-analysing the heated ELISA lysate (100°C, 10 min), or by performing Plasmodium specific PCR followed if possible by sequencing of the amplicons for Plasmodium species determination. PMID:21767376
Kitashoji, Emi; Koizumi, Nobuo; Lacuesta, Talitha Lea V; Usuda, Daisuke; Ribo, Maricel R; Tria, Edith S; Go, Winston S; Kojiro, Maiko; Parry, Christopher M; Dimaano, Efren M; Villarama, Jose B; Ohnishi, Makoto; Suzuki, Motoi; Ariyoshi, Koya
2015-01-01
Leptospirosis is an important but largely under-recognized public health problem in the tropics. Establishment of highly sensitive and specific laboratory diagnosis is essential to reveal the magnitude of problem and to improve treatment. This study aimed to evaluate the diagnostic accuracy of a recombinant LigA protein based IgM ELISA during outbreaks in the clinical-setting of a highly endemic country. A prospective study was conducted from October 2011 to September 2013 at a national referral hospital for infectious diseases in Manila, Philippines. Patients who were hospitalized with clinically suspected leptospirosis were enrolled. Plasma and urine were collected on admission and/or at discharge and tested using the LigA-IgM ELISA and a whole cell-based IgM ELISA. Sensitivity and specificity of these tests were evaluated with cases diagnosed by microscopic agglutination test (MAT), culture and LAMP as the composite reference standard and blood bank donors as healthy controls: the mean+3 standard deviation optical density value of healthy controls was used as the cut-off limit (0.062 for the LigA-IgM ELISA and 0.691 for the whole cell-based IgM ELISA). Of 304 patients enrolled in the study, 270 (89.1%) were male and the median age was 30.5 years; 167 (54.9%) were laboratory confirmed. The sensitivity and ROC curve AUC for the LigA-IgM ELISA was significantly greater than the whole cell-based IgM ELISA (69.5% vs. 54.3%, p<0.01; 0.90 vs. 0.82, p<0.01) on admission, but not at discharge. The specificity of LigA-IgM ELISA and whole cell-based IgM ELISA were not significantly different (98% vs. 97%). Among 158 MAT negative patients, 53 and 28 were positive by LigA- and whole cell-based IgM ELISA, respectively; if the laboratory confirmation was re-defined by LigA-IgM ELISA and LAMP, the clinical findings were more characteristic of leptospirosis than the diagnosis based on MAT/culture/LAMP. The newly developed LigA-IgM ELISA is more sensitive than the whole cell-based IgM based ELISA. Although the final diagnosis must be validated by more specific tests, LigA-IgM ELISA could be a useful diagnostic test in a real clinical-setting, where diagnosis is needed in the early phase of infection.
Kitashoji, Emi; Koizumi, Nobuo; Lacuesta, Talitha Lea V.; Usuda, Daisuke; Ribo, Maricel R.; Tria, Edith S.; Go, Winston S.; Kojiro, Maiko; Parry, Christopher M.; Dimaano, Efren M.; Villarama, Jose B.; Ohnishi, Makoto; Suzuki, Motoi; Ariyoshi, Koya
2015-01-01
Background Leptospirosis is an important but largely under-recognized public health problem in the tropics. Establishment of highly sensitive and specific laboratory diagnosis is essential to reveal the magnitude of problem and to improve treatment. This study aimed to evaluate the diagnostic accuracy of a recombinant LigA protein based IgM ELISA during outbreaks in the clinical-setting of a highly endemic country. Methodology/Principal Findings A prospective study was conducted from October 2011 to September 2013 at a national referral hospital for infectious diseases in Manila, Philippines. Patients who were hospitalized with clinically suspected leptospirosis were enrolled. Plasma and urine were collected on admission and/or at discharge and tested using the LigA-IgM ELISA and a whole cell-based IgM ELISA. Sensitivity and specificity of these tests were evaluated with cases diagnosed by microscopic agglutination test (MAT), culture and LAMP as the composite reference standard and blood bank donors as healthy controls: the mean+3 standard deviation optical density value of healthy controls was used as the cut-off limit (0.062 for the LigA-IgM ELISA and 0.691 for the whole cell-based IgM ELISA). Of 304 patients enrolled in the study, 270 (89.1%) were male and the median age was 30.5 years; 167 (54.9%) were laboratory confirmed. The sensitivity and ROC curve AUC for the LigA-IgM ELISA was significantly greater than the whole cell-based IgM ELISA (69.5% vs. 54.3%, p<0.01; 0.90 vs. 0.82, p<0.01) on admission, but not at discharge. The specificity of LigA-IgM ELISA and whole cell-based IgM ELISA were not significantly different (98% vs. 97%). Among 158 MAT negative patients, 53 and 28 were positive by LigA- and whole cell-based IgM ELISA, respectively; if the laboratory confirmation was re-defined by LigA-IgM ELISA and LAMP, the clinical findings were more characteristic of leptospirosis than the diagnosis based on MAT/culture/LAMP. Conclusions/Significance The newly developed LigA-IgM ELISA is more sensitive than the whole cell-based IgM based ELISA. Although the final diagnosis must be validated by more specific tests, LigA-IgM ELISA could be a useful diagnostic test in a real clinical-setting, where diagnosis is needed in the early phase of infection. PMID:26110604
Parker, A M; House, J K; Hazelton, M S; Bosward, K L; Morton, J M; Sheehy, P A
2017-10-01
In Australia, one of the biosecurity recommendations to help prevent the introduction of Mycoplasma bovis into a dairy herd is to use a PCR assay on bulk tank milk (BTM) samples to evaluate the M. bovis infection status of potential source herds. An alternative approach is to assess the immunological status of the herd with respect to previous exposure to M. bovis via the use of an ELISA that is commercially available for use on cattle milk and serum. The objectives of this study were to (1) evaluate factors potentially associated with variation in the ELISA BTM optical density coefficient (ODC%) in previously exposed herds, (2) evaluate the association between the proportion of cows that are ELISA positive and the BTM ELISA ODC%, (3) assess agreement between the BTM ELISA and PCR and culture, and (4) compare BTM ELISA ODC% between the "hospital" herd and the main lactating herd on the same farm. Bulk tank milk samples (n = 192) were collected from 19 dairy herds with a history of clinical M. bovis disease and from 6 control herds (herds with no known clinical cases of mycoplasmosis). For 28 of the BTM samples collected, blood was also collected from 50 lactating cows contributing to that bulk tank sample. From 1 herd, concurrent paired BTM samples were collected from the main herd and the hospital herd on 16 occasions. All BTM samples were analyzed by ELISA (Bio-X Bio K 302, Bio-X Diagnostics, Rochefort, Belgium), PCR, and culture. The BTM ELISA ODC% was associated with time since initial M. bovis outbreak and time since the start of the herd's calving period. Following an initial outbreak of M. bovis, the BTM ELISA ODC% was highest in the first 8 mo. In split- and seasonal-calving herds, significantly higher BTM ELISA ODC% results were observed 5 to 8 wk after the commencement of the calving period. A significant association was observed between the within-herd seroprevalence for the lactating herd and BTM ELISA ODC%, but within-herd seroprevalence explained little of the variation in BTM ELISA ODC%. When comparing the BTM ELISA with a multiplex probe PCR and culture followed by 16S to 23S rRNA sequencing, there was virtually no agreement above that expected by chance; prevalence-adjusted bias-adjusted kappa values were 0.22 and 0.25 for ELISA category versus PCR category and culture, respectively. Finally, the hospital herd BTM ELISA ODC% mirrored that for the main herd BTM but was significantly higher. This study demonstrates that this commercially available ELISA used on BTM samples may complement the use of BTM PCR or culture in identifying herds from which purchase of animals may pose a higher biosecurity risk for introduction of M. bovis into noninfected herds. Copyright © 2017 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Kumar, Saroj; Ahirwar, Rajesh; Rehman, Ishita; Nahar, Pradip
2017-07-01
Rapid diagnostic tests can be developed using ELISA for detection of diseases in emergency conditions. Conventional ELISA takes 1-2 days, making it unsuitable for rapid diagnostics. Here, we report the effect of reagents mixing via shaking or vortexing on the assay timing of ELISA. A 48-min protocol of ELISA involving 12-min incubations with reagent mixing at 750 rpm for every step was optimized. Contrary to this, time-optimized control ELISA performed without mixing produced similar results in 8 h, leaving a time gain of 7 h using the developed protocol. Collectively, the findings suggest the development of ELISA-based rapid diagnostics. Copyright © 2017 Elsevier Inc. All rights reserved.
Fukushi, Shuetsu; Fukuma, Aiko; Kurosu, Takeshi; Watanabe, Shumpei; Shimojima, Masayuki; Shirato, Kazuya; Iwata-Yoshikawa, Naoko; Nagata, Noriyo; Ohnishi, Kazuo; Ato, Manabu; Melaku, Simenew Keskes; Sentsui, Hiroshi; Saijo, Masayuki
2018-01-01
Since discovering the Middle East respiratory syndrome coronavirus (MERS-CoV) as a causative agent of severe respiratory illness in the Middle East in 2012, serological testing has been conducted to assess antibody responses in patients and to investigate the zoonotic reservoir of the virus. Although the virus neutralization test is the gold standard assay for MERS diagnosis and for investigating the zoonotic reservoir, it uses live virus and so must be performed in high containment laboratories. Competitive ELISA (cELISA), in which a labeled monoclonal antibody (MAb) competes with test serum antibodies for target epitopes, may be a suitable alternative because it detects antibodies in a species-independent manner. In this study, novel MAbs against the spike protein of MERS-CoV were produced and characterized. One of these MAbs was used to develop a cELISA. The cELISA detected MERS-CoV-specific antibodies in sera from MERS-CoV-infected rats and rabbits immunized with the spike protein of MERS-CoV. The MAb-based cELISA was validated using sera from Ethiopian dromedary camels. Relative to the neutralization test, the cELISA detected MERS-CoV-specific antibodies in 66 Ethiopian dromedary camels with a sensitivity and specificity of 98% and 100%, respectively. The cELISA and neutralization test results correlated well (Pearson's correlation coefficients=0.71-0.76, depending on the cELISA serum dilution). This cELISA may be useful for MERS epidemiological investigations on MERS-CoV infection. Copyright © 2017 Elsevier B.V. All rights reserved.
Jaskowski, Troy D; La'ulu, Sonia L; Mahler, Michael; Tebo, Anne E
2017-09-01
We investigated the performance of an ELISA for the detection of 3-hydroxy-3-methyl-glutaryl-coenzyme A reductase (HMGCR) IgG antibodies in immune-mediated necrotizing myopathies (IMNM). Patients positive for HMGCR antibodies (n=61) or negative (n=78) by protein immunoprecipitation (IP), and healthy controls (n=100) were used to evaluate the ELISA. Unique consecutive serum samples (n=155) received at ARUP Laboratories for HMGCR IgG testing by ELISA were also investigated and analysed for serum muscle enzymes (aldolase, creatine kinase, and myoglobin). The ELISA's sensitivity, specificity, and percentage agreement were assessed relative to IP. Correlation between specific muscle enzyme concentration and the presence of HMGCR antibody was determined. Overall agreement between ELISA and IP was 93.4%. Using the IP as reference, the sensitivity and specificity of the ELISA was 95.1%, and 100%, respectively. Inter- and intra-assay coefficient of variation of the ELISA was <10.0%, and ≤15.0%, respectively. In the consecutive cohort, 21 (13.6%) samples tested positive for HMGCR IgG. Concentrations of aldolase, creatine kinase, and myoglobin were significantly higher (all p<0.0001) in patients positive for HMGCR antibodies at the time of evaluation. We confirm significant reliability of HMGCR antibodies as measured by the ELISA for the evaluation of IMNM. Copyright © 2017 Elsevier B.V. All rights reserved.
Detection of liver kidney microsomal type 1 antibody using molecularly based immunoassays
Kerkar, N; Ma, Y; Davies, E T; Cheeseman, P; Mieli-Vergani, G; Vergani, D
2002-01-01
Aims: To assess the diagnostic value of two commercial molecularly based immunoassays detecting liver kidney microsomal type 1 antibody (LKM1). Methods: The performance of Varelisa and LKM1 enzyme linked immunosorbent assay (ELISA) was compared with immunofluorescence, and two validated research techniques—an in house ELISA and a radioligand assay measuring antibodies to P4502D6. Thirty serum samples from three patients with autoimmune hepatitis type 2 covering immunofluorescence titres of 1/10 to 1/10 240 and 55 LKM1 negative controls were tested. Results: All 30 sera that were LKM1 positive by immunofluorescence were positive by the in house ELISA, the radioligand assay, and LKM1-ELISA, and 29 were also positive by Varelisa. None of the 55 sera negative for LKM1 by immunofluorescence was positive by the in house ELISA and radioligand assay, but one was positive by Varelisa and 14 were positive using the LKM1-ELISA. Agreement between immunofluorescence, the in house ELISA, the radioligand assay, and Varelisa was high (κ > 0.8), and agreement between immunofluorescence and LKM1-ELISA was moderate (κ = 0.63). Conclusion: The assay kit marketed as Varelisa allows accurate detection of LKM1. PMID:12461054
Detection of liver kidney microsomal type 1 antibody using molecularly based immunoassays.
Kerkar, N; Ma, Y; Davies, E T; Cheeseman, P; Mieli-Vergani, G; Vergani, D
2002-12-01
To assess the diagnostic value of two commercial molecularly based immunoassays detecting liver kidney microsomal type 1 antibody (LKM1). The performance of Varelisa and LKM1 enzyme linked immunosorbent assay (ELISA) was compared with immunofluorescence, and two validated research techniques-an in house ELISA and a radioligand assay measuring antibodies to P4502D6. Thirty serum samples from three patients with autoimmune hepatitis type 2 covering immunofluorescence titres of 1/10 to 1/10 240 and 55 LKM1 negative controls were tested. All 30 sera that were LKM1 positive by immunofluorescence were positive by the in house ELISA, the radioligand assay, and LKM1-ELISA, and 29 were also positive by Varelisa. None of the 55 sera negative for LKM1 by immunofluorescence was positive by the in house ELISA and radioligand assay, but one was positive by Varelisa and 14 were positive using the LKM1-ELISA. Agreement between immunofluorescence, the in house ELISA, the radioligand assay, and Varelisa was high (kappa > 0.8), and agreement between immunofluorescence and LKM1-ELISA was moderate (kappa = 0.63). The assay kit marketed as Varelisa allows accurate detection of LKM1.
Aydin, Suleyman
2015-10-01
Playing a critical role in the metabolic homeostasis of living systems, the circulating concentrations of peptides/proteins are influenced by a variety of patho-physiological events. These peptide/protein concentrations in biological fluids are measured using various methods, the most common of which is enzymatic immunoassay EIA/ELISA and which guide the clinicians in diagnosing and monitoring diseases that inflict biological systems. All the techniques where enzymes are employed to show antigen-antibody reactions are generally referred to as enzymatic immunoassay EIA/ELISA method. Since the basic principles of EIA and ELISA are the same. The main objective of this review is to present an overview of the historical journey that had led to the invention of EIA/ELISA, an indispensible method for medical and research laboratories, types of ELISA developed after its invention [direct (the first ELISA method invented), indirect, sandwich and competitive methods], problems encountered during peptide/protein analyses (pre-analytical, analytical and post-analytical), rules to be followed to prevent these problems, and our laboratory experience of more than 15 years. Copyright © 2015 Elsevier Inc. All rights reserved.
Homologous ELISA for detection of oligomeric human TNF: properties of the assay.
Petyovka, N; Lyach, L; Voitenok, N N
1995-10-26
In order to quantify oligomeric human tumor necrosis factor-alpha (TNF), we have developed a sensitive homologous enzyme-linked immunosorbent assay (Hm-ELISA) using the same monoclonal antibody (MoAb) for both solid and liquid phase. Different anti-TNF MoAb have been compared in terms of their efficacy in the Hm-ELISA, affinity, neutralization capacity and epitope specificity. The data suggest, that effectiveness in the Hm-ELISA may represent a novel characteristic of MoAb. Of the MoAbs tested, 5 N was capable of recognizing oligomeric TNF in the Hm-ELISA with a detection limit of 15 pg/ml. Furthermore, using Hm-ELISA against human TNF, interleukin-8 (IL-8) and lymphotoxin, we have demonstrated that these cytokines are oligomeric in physiological solutions, but are converted into monomeric forms in the presence of the non-ionic detergent Tween 20. High salt buffer was employed to abrogate a nonspecific false positive reaction in the Hm-ELISA found in nearly half of the plasma samples obtained from healthy subjects. Finally, a good correlation between the Hm-ELISA and the L929 bioassay was observed for natural and recombinant TNF measured in human plasma.
[Use of new immunoglobulin isotype-specific ELISA-systems to detect Salmonella infections in pigs].
Ehlers, Joachim; Alt, Michael; Trepnau, Daniela; Lehmann, Jörg
2006-01-01
In Germany, the program for controlling salmonella infections in pigs is based on tests detecting salmonella-lipopolysaccharide (LPS) induced antibodies in meat-juice or blood. These conventional tests which are based on the technology of enzyme-linked immunosorbent assay (ELISA) detect exclusively or mainly immunoglobulin(lg)G antibodies. Meanwhile, novel ELISA systems (WCE-ELISA, 3-Isotype-Screening-ELISA) have been developed, which additionally detect the antibody classes IgM and IgA.This fact enables the registration of fresh salmonella infections (starting with day 5 p.i.) and thus, the distinction between early and older infections. The results show that animals with early salmonella infections appear significantly more often in herds with a high than with a low prevalence. With the newly developed tests this group of animals can be detected much more efficiently and precisely than with the tests used so far. Due to their clearly improved sensitivity the application of the WCE-ELISA and the 3-Isotype-Screening-ELISA in terms of the QS-Salmonella-Monitoring program can therefore significantly improve the selection of farms with potential salmonella excretors. Additionally, the WCE-ELISA can be applied very suitable for the examination of individual animals.
Evaluating concentration estimation errors in ELISA microarray experiments
DOE Office of Scientific and Technical Information (OSTI.GOV)
Daly, Don S.; White, Amanda M.; Varnum, Susan M.
Enzyme-linked immunosorbent assay (ELISA) is a standard immunoassay to predict a protein concentration in a sample. Deploying ELISA in a microarray format permits simultaneous prediction of the concentrations of numerous proteins in a small sample. These predictions, however, are uncertain due to processing error and biological variability. Evaluating prediction error is critical to interpreting biological significance and improving the ELISA microarray process. Evaluating prediction error must be automated to realize a reliable high-throughput ELISA microarray system. Methods: In this paper, we present a statistical method based on propagation of error to evaluate prediction errors in the ELISA microarray process. Althoughmore » propagation of error is central to this method, it is effective only when comparable data are available. Therefore, we briefly discuss the roles of experimental design, data screening, normalization and statistical diagnostics when evaluating ELISA microarray prediction errors. We use an ELISA microarray investigation of breast cancer biomarkers to illustrate the evaluation of prediction errors. The illustration begins with a description of the design and resulting data, followed by a brief discussion of data screening and normalization. In our illustration, we fit a standard curve to the screened and normalized data, review the modeling diagnostics, and apply propagation of error.« less
Giraldo, Mónica; Portela, Ricardo W. D.; Snege, Mirian; Leser, Paulo G.; Camargo, Mário E.; Mineo, José Roberto; Gazzinelli, Ricardo T.
2002-01-01
In the present study we developed an enzyme-linked immunosorbent assay (ELISA) to measure immunoglobulin M (IgM) specific for glycoinositolphospholipids (GIPL) derived from tachyzoite membrane (IgM-GIPL ELISA). The sensitivity and specificity of the assay were compared with those of commercially available Toxoplasma-specific IgM serological tests, namely, immunofluorescence assay (IFA) with fixed tachyzoites and capture ELISA employing tachyzoite extracts. Our results show that all patients with acute toxoplasmosis, as determined by clinical data and conventional serological tests, were also positive by the IgM-GIPL ELISA. Interestingly, many patients that were classified as indeterminate, who had IgG with high avidity but positive results in the IgM-specific IFA and capture ELISA, were negative by the IgM-GIPL ELISA. Finally, we tested the sera from patients with rheumatoid arthritis and various parasitic infections and found no evidence of false positives in the IgM-GIPL ELISA. PMID:11923364
Optofluidic laser for dual-mode sensitive biomolecular detection with a large dynamic range
NASA Astrophysics Data System (ADS)
Wu, Xiang; Oo, Maung Kyaw Khaing; Reddy, Karthik; Chen, Qiushu; Sun, Yuze; Fan, Xudong
2014-04-01
Enzyme-linked immunosorbent assay (ELISA) is a powerful method for biomolecular analysis. The traditional ELISA employing light intensity as the sensing signal often encounters large background arising from non-specific bindings, material autofluorescence and leakage of excitation light, which deteriorates its detection limit and dynamic range. Here we develop the optofluidic laser-based ELISA, where ELISA occurs inside a laser cavity. The laser onset time is used as the sensing signal, which is inversely proportional to the enzyme concentration and hence the analyte concentration inside the cavity. We first elucidate the principle of the optofluidic laser-based ELISA, and then characterize the optofluidic laser performance. Finally, we present the dual-mode detection of interleukin-6 using commercial ELISA kits, where the sensing signals are simultaneously obtained by the traditional and the optofluidic laser-based ELISA, showing a detection limit of 1 fg ml-1 (38 aM) and a dynamic range of 6 orders of magnitude.
Chung, Chungwon J; Suarez, Carlos E; Bandaranayaka-Mudiyanselage, Carey L; Bandaranayaka-Mudiyanselage, Chandima-Bandara; Rzepka, Joanna; Heiniger, T J; Chung, Grace; Lee, Stephen S; Adams, Ethan; Yun, Grace; Waldron, Susan J
2017-02-13
Cattle persistently infected with Babesia bovis are reservoirs for intra- and inter-herd transmission. Since B. bovis is considered a persistent infection, developing a reliable, high-throughput assay that detects antibody during all stages of the infection could be pivotal for establishing better control protocols. A modified indirect enzyme-linked immunosorbent assay (MI-ELISA) was developed using the spherical body protein-4 (SBP4) of B. bovis to detect antibody against diverse strains through all infection stages in cattle. This SBP4 MI-ELISA was evaluated for sensitivity and specificity against field sera from regions with endemic and non-endemic B. bovis. Sera were also evaluated from cattle infected experimentally with various doses and strains during acute and persistent infection with parasitemia defined by nested PCR. The format variables for SBP4 MI-ELISA were optimized and the cutoff for positive and negative interpretation was determined based on receiver operating characteristic curve analysis using B. bovis positive and negative sera tested in the reference immunofluorescence assay (IFA). The diagnostic specificity of the SBP4 MI-ELISA using IFA-negative sera collected from Texas was 100%, significantly higher than the cELISA (90.4%) based on an epitope in the rhoptry-associated protein-1 (RAP-1 cELISA). The diagnostic sensitivity of the SBP4 MI-ELISA was 98.7% using the IFA-positive sera collected from several areas of Mexico, in contrast to that of the RAP-1 cELISA at 60% using these same sera. In cattle infected with low and high doses of three B. bovis strains, the SBP4 MI-ELISA remained antibody positive for 11 months or more after initial detection at 10 to 13 days post-inoculation. However, the RAP-1 cELISA did not reliably detect antibody after eight months post-inoculation despite the fact that parasitemia was occasionally detectable by PCR. Furthermore, initial antibody detection by RAP-1 cELISA in low-dose infected animals was delayed approximately nine and a half days compared to the SBP4 MI-ELISA. These results demonstrate excellent diagnostic sensitivity and specificity of the novel SBP4 MI-ELISA for cattle with acute and long-term carrier infections. It is posited that use of this assay in countries that have B. bovis-endemic herds may be pivotal in preventing the spread of this disease to non-endemic herds.
Code of Federal Regulations, 2012 CFR
2012-01-01
...) Enzyme-linked immunosorbent assay (ELISA). ELISA must be conducted using test kits approved by the... conducted on all ELISA-positive samples. (B) The AGID test must be conducted using reagents approved by the...
Code of Federal Regulations, 2013 CFR
2013-01-01
...) Enzyme-linked immunosorbent assay (ELISA). ELISA must be conducted using test kits approved by the... conducted on all ELISA-positive samples. (B) The AGID test must be conducted using reagents approved by the...
Code of Federal Regulations, 2010 CFR
2010-01-01
...) Enzyme-linked immunosorbent assay (ELISA). ELISA must be conducted using test kits approved by the... conducted on all ELISA-positive samples. (B) The AGID test must be conducted using reagents approved by the...
Code of Federal Regulations, 2014 CFR
2014-01-01
...) Enzyme-linked immunosorbent assay (ELISA). ELISA must be conducted using test kits approved by the... conducted on all ELISA-positive samples. (B) The AGID test must be conducted using reagents approved by the...
Code of Federal Regulations, 2011 CFR
2011-01-01
...) Enzyme-linked immunosorbent assay (ELISA). ELISA must be conducted using test kits approved by the... conducted on all ELISA-positive samples. (B) The AGID test must be conducted using reagents approved by the...
This paper describes the development of a 96-microwell high sample capacity ELISA method for measuring 2,4-D in urine; the analysis of 2,4-D in real-world urine samples by both ELISA and GC/MS methods; and compares the ELISA and GC/MS results in several key areas: accuracy, preci...
Chemiluminescent optical fiber immunosensor for the detection of anti-West Nile virus IgG.
Herrmann, Sebastien; Leshem, Boaz; Landes, Shimi; Rager-Zisman, Bracha; Marks, Robert S
2005-03-31
An ELISA-based optical fiber methodology developed for the detection of anti-West Nile virus IgG antibodies in serum was compared to standard colorimetric and chemiluminescent ELISA based on microtiter plates. Colorimetric ELISA was the least sensitive, especially at high titer dilutions. The fiber-optic immunosensor based on the same ELISA immunological rationale was the most sensitive technique.
Mwanjali, Gloria; Kihamia, Charles; Kakoko, Deodatus Vitalis Conatus; Lekule, Faustin; Ngowi, Helena; Johansen, Maria Vang; Thamsborg, Stig Milan; Willingham, Arve Lee
2013-01-01
Background Taenia solium cysticercosis/taeniosis is emerging as a serious public health and economic problem in many developing countries. This study was conducted to determine prevalence and risk factors of human T. solium infections in Mbeya Region, Tanzania. Methods and Findings A cross-sectional survey was conducted in 13 villages of Mbozi district in 2009. Sera of 830 people (mean 37.9±11.3 years (SD); 43% females) were tested for circulating cysticerci antigen (Ag-ELISA) and antibody (Ab-ELISA). A subset of persons found seropositive by Ag-ELISA underwent computed tomography (CT) scan of the brain for evidence of neurocysticercosis. Stool samples from 820 of the same participants were tested for taeniosis by copro-antigens (copro-Ag-ELISA) and formol-ether concentration technique. Cases of T. solium taeniosis were confirmed serologically by EITB assay (rES38). A questionnaire was used for identification of risk factors. Active cysticercosis by positive Ag-ELISA was found in 139 (16.7%) persons while anti-cysticercal antibodies were detected in 376 (45.3%) persons by Ab-ELISA. Among 55 persons positive for Ag-ELISA undergoing CT scan, 30 (54.6%) were found to have structures in the brain suggestive of neurocysticercosis. Using faecal analysis, 43 (5.2%) stool samples tested positive for taeniosis by copro-Ag-ELISA while Taenia eggs were detected in 9 (1.1%) stool samples by routine coprology. Antibodies specifically against adult T. solium were detected in 34 copro-Ag-ELISA positive participants by EITB (rES38) indicating T. solium taeniosis prevalence of 4.1%. Increasing age and hand washing by dipping in contrast to using running water, were found associated with Ag-ELISA seropositivity by logistic regression. Gender (higher risk in females) and water source were risk factors associated with Ab-ELISA seropositivity. Reported symptoms of chronic severe headaches and history of epileptic seizures were found associated with positive Ag-ELISA (p≤0.05). Conclusion The present study indicates T. solium infection in humans is highly endemic in the southern highlands of Tanzania. PMID:23516650
Denburg, Michelle R.; Hoofnagle, Andrew N.; Sayed, Samir; Gupta, Jayanta; de Boer, Ian H.; Appel, Lawrence J.; Durazo-Arvizu, Ramon; Whitehead, Krista; Feldman, Harold I.; Leonard, Mary B.
2016-01-01
Studies using vitamin D-binding protein (DBP) concentrations to estimate free and bioavailable vitamin D have increased dramatically in recent years. Combinations of two single-nucleotide polymorphisms produce three major DBP isoforms (Gc1f, Gc1s and Gc2). A recent study showed that DBP concentrations quantified by liquid chromatography-tandem mass spectrometry (LC-MS/MS) did not differ by race, while a widely used monoclonal ELISA quantified DBP differentially by isoform, yielding significantly lower DBP concentrations in black versus white individuals. We compared measurements of serum DBP using a monoclonal ELISA, a polyclonal ELISA, and LC-MS/MS in 125 participants in the Chronic Renal Insufficiency Cohort. Serum free and bioavailable 25OHD were calculated based on DBP concentrations from these three assays in homozygous participants, and race differences were compared. We confirmed that the monoclonal ELISA quantifies DBP differentially by isoform and demonstrated that the polyclonal ELISA is not subject to this bias. While ≤9% of the variability in DBP concentrations quantified using either LC-MS/MS or the polyclonal ELISA was explained by genotype, 85% of the variability in the monoclonal ELISA-based measures was explained by genotypes. DBP concentrations measured by the monoclonal ELISA were disproportionately lower than LC-MS/MS-based results for Gc1f homozygotes [median difference −67%; interquartile range (IQR) −71%, −64%], 95% of whom were black. In contrast, the polyclonal ELISA yielded consistently and similarly higher measurements of DBP than LC-MS/MS, irrespective of genotype, with a median percent difference of +50% [IQR +33%, +65%]. Contrary to findings using the monoclonal ELISA, DBP concentrations did not differ by race, and free and bioavailable 25OHD were significantly lower in black versus white participants based on both the polyclonal ELISA and LC-MS/MS, consistent with their lower total 25OHD. Future studies of DBP and free or bioavailable vitamin D metabolites should employ DBP assays that are not biased by DBP genotype. PMID:27250744
Udomsin, Orapin; Krittanai, Supaluk; Kitisripanya, Tharita; Tanaka, Hiroyuki; Putalun, Waraporn
2017-01-01
Background: Puerarin (PUE) is a phytoestrogen found in Pueraria candollei and Pueraria lobata. These plants are substantial for traditional medicine in various Asian countries. PUE is a key marker that can be found only in the Pueraria species. Objective: To establish the method for determination of PUE content which is required for quality control of pharmaceutical products. Materials and Methods: PUE-cationized bovine serum albumin conjugate was created via Mannich reaction. After the rabbit immunization, the obtain anti-PUE polyclonal antibody (PAb) was used to develop an enzyme-linked immunosorbent assay (ELISA). Results: An anti-PUE PAb possess a great sensitivity and specificity. The cross-reactivity analysis shows no cross-reaction of an established antibody against other substances. In addition, we successfully developed an indirect competitive ELISA (icELISA) for the quantitative analysis of PUE. The result of method validation conforms to acceptance criteria and correlates with high-performance liquid chromatography, the reference method. The icELISA was applied to determine PUE content in Pueraria spp. plant samples and its derived pharmaceutical products. Conclusion: This highly specific immunogen was created from the Mannich reaction. An icELISA can also be applied to other research propose in the further studies. SUMMARY The new immunogen conjugated (puerarin-cBSA) via Mannich reaction was successfully in rising of antibody against puerarin (PUE)The obtained anti-PUE polyclonal antibody (PAb) was high sensitivity and specificity to PUEAn indirect competitive enzyme-linked immunosorbent assay (icELISA) was developed and validated using anti-PUE PAbThe established icELISA was applied to determine PUE content in various tuberous root of Pueraria sppMoreover, icELISA method can be applicable in Pueraria spp. derived products. Abbreviations used: PUE: Puerarin; PAb: Polyclonal antibody; ELISA: Enzyme-linked immunosorbent assay; icELISA: Indirect competitive ELISA; cBSA: Cationized bovine serum albumin. PMID:29491643
Ito, Kaori; Yamamoto, Takayuki; Oyama, Yuriko; Tsuruma, Rieko; Saito, Eriko; Saito, Yoshikazu; Ozu, Takeshi; Honjoh, Tsutomu; Adachi, Reiko; Sakai, Shinobu; Akiyama, Hiroshi; Shoji, Masahiro
2016-09-01
Enzyme-linked immunosorbent assay (ELISA) is commonly used to determine food allergens in food products. However, a significant number of ELISAs give an erroneous result, especially when applied to highly processed food. Accordingly, an improved ELISA, which utilizes an extraction solution comprising the surfactant sodium lauryl sulfate (SDS) and reductant 2-mercaptoethanol (2-ME), has been specially developed to analyze food allergens in highly processed food by enhancing analyte protein extraction. Recently, however, the use of 2-ME has become undesirable. In the present study, a new extraction solution containing a human- and eco-friendly reductant, which is convenient to use at the food manufacturing site, has been established. Among three chemicals with different reducing properties, sodium sulfite, tris(3-hydroxypropyl)phosphine, and mercaptoethylamine sodium sulfite was selected as a 2-ME substitute. The protein extraction ability of SDS/0.1 M sodium sulfite solution was comparable to that of SDS/2-ME solution. Next, the ELISA performance for egg, milk, wheat, peanut, and buckwheat was evaluated by using model-processed foods and commercially available food products. The data showed that the SDS/0.1 M sulfite ELISA significantly correlated with the SDS/2-ME ELISA for all food allergens examined (p < 0.01), thereby establishing the validity of the SDS/0.1 M sulfite ELISA performance. Furthermore, the new SDS/0.1 M sulfite solution was investigated for its applicability to the lateral-flow (LF) test. The result demonstrated the successful analysis of food allergens in processed food, showing consistency with the SDS/0.1 M sulfite ELISA results. Accordingly, a harmonized analysis system for processed food comprising a screening LF test and a quantitative ELISA with identical extraction solution has been established. The ELISA based on the SDS/0.1 M sulfite extraction solution has now been authorized as the revised official method for food allergen analysis in Japan.
ELISA for sulfonamides and its application for screening in water contamination.
Shelver, Weilin L; Shappell, Nancy W; Franek, Milan; Rubio, Fernando R
2008-08-13
Two enzyme-linked immunosorbent assays (ELISAs) were tested for their suitability for detecting sulfonamides in wastewater from various stages in wastewater treatment plants (WWTPs), the river into which the wastewater is discharged, and two swine-rearing facilities. The sulfamethoxazole ELISA cross-reacts with several compounds, achieving detection limits of <0.04 microg/L for sulfamethoxazole (SMX), sulfamethoxypyridine, sulfachloropyridine, and sulfamethoxine, whereas the sulfamethazine (SMZ) ELISA is more compound specific, with a detection limit of <0.03 microg/L. Samples from various stages of wastewater purifications gave 0.6-3.1 microg/L by SMX-ELISA, whereas river samples were approximately 10-fold lower, ranging from below detection to 0.09 microg/L. Swine wastewater samples analyzed by the SMX-ELISA were either at or near detectable limits from one facility, whereas the other facility had concentrations of approximately 0.5 microg/L, although LC-MS/MS did not confirm the presence of SMX. Sulfamethazine ELISA detected no SMZ in either WWTP or river samples. In contrast, wastewater samples from swine facilities analyzed by SMZ-ELISA were found to contain approximately 30 microg/L [piglet (50-100 lb) wastewater] and approximately 7 microg/L (market-weight hog wastewater). Sulfamethazine ELISA analyses of wastewater from another swine facility found concentrations to be near or below detection limits. A solid phase extraction method was used to isolate and concentrate sulfonamides from water samples prior to LC-MS/MS multiresidue confirmatory analysis. The recoveries at 1 microg/L fortification ranged from 42 +/- 4% for SMZ to 88 +/- 4% for SMX ( n = 6). The ELISA results in the WWTPs were confirmed by LC-MS/MS, as sulfonamide multiresidue confirmatory analysis identified SMX, sulfapyridine, and sulfasalazine to be present in the wastewater. Sulfamethazine presence at one swine-rearing facility was also confirmed by LC-MS/MS, demonstrating the usefulness of the ELISA technique as a rapid and high-throughput screening method.
Salgado, Miguel; Kruze, Juan; Collins, Michael T
2007-01-01
Fecal culture has been the primary method used to diagnose paratuberculosis in goats. It is laborious, slow, and expensive. Validation of enzyme-linked immunosorbent assays (ELISAs) on milk samples could make paratuberculosis testing more widely available for goat farmers. The aim of this study was to determine the accuracy of serum and milk ELISAs for paratuberculosis, relative to fecal culture, in Chilean dairy goats. Eight dairy goat herds were selected. Feces, blood, and milk samples were collected from all female goats >2 years old. Fecal samples were cultured using Herrold egg yolk medium with mycobactin J and antibiotics. Serum and milk samples were tested using a commercial ELISA kit for Mycobacterium avium subsp. paratuberculosis antibody detection. A total of 383 goats were tested by ELISA and fecal culture. The sensitivity of ELISA on serum and milk relative to fecal culture was 74.3% (95% CI: 59.8-88.8) and 60% (95% CI: 43.8-76.2), respectively. The corresponding values for ELISA specificity based on the percentage of non- M. avium subsp. paratuberculosis-infected goats testing ELISA-negative were 98.6% (95% CI: 96.6-100) and 99.3% (95% CI: 97.9-100) on serum and milk, respectively. Proportions of positive results for serum and fecal samples were significantly different, whereas the proportions of positive results for milk and fecal samples were not significantly different. The milk ELISA had a moderate level of agreement with fecal culture results (Kappa = 0.57). The paratuberculosis ELISA on goat milk samples may be a cost-effective, accurate alternative to fecal culture.
Evaluation of commercial ELISA kits for the detection of antibodies against bluetongue virus.
Niedbalski, W
2011-01-01
The aim of this study was to estimate the diagnostic value of different commercially available ELISA kits for the detection of bluetongue virus (BTV) antibodies in infected and vaccinated animals. The relative specificity of ELISA kits was evaluated using a panel of sera originating from healthy cattle, never vaccinated nor exposed to BTV. All ELISA kits applied had a high relative specificity (99.3 - 100%). The relative sensitivity of ELISA kits assessed using a panel of sera collected from BTV infected cattle was also high and similar for all the kits (97.3 - 100%). However, the relative sensitivity evaluated on the basis of testing vaccinated animals was different: the highest sensitivity was found for Ingenasa, PrioCHECK and ID VET ELISAs (96.5 - 98.3%). Slightly lower sensitivity was calculated for Pourquier and LSI kits (82.8% and 85.4%, respectively) and much lower sensitivity was found for VMRD ELISA kit (69.5%). The repeatability of BTV ELISA kits was expressed as a coefficient of variation (CV) of results of sera tested 5 times in the same day and in different days by the period of 2 months, by the same person, in the same conditions, and by using the same equipment. The CVs of sera tested in all ELISA kits ranged from 6.1 to 9.8% and were below 10% threshold adopted as a maximum for the acceptable repeatability of the method. In conclusion, it can be stated that the applied ELISA kits can be a valuable diagnostic tool for the serological monitoring studies in the BTV contaminated premises. All the methods are very specific and sensitive when testing BTV infected animals. Nevertheless, the Ingenasa and PrioCHECK can be the most useful in sero-surveillance of livestock following vaccination.
Proksch, A L; Unterer, S; Speck, S; Truyen, U; Hartmann, K
2015-06-01
False negative faecal canine parvovirus (CPV) antigen ELISA results in dogs with CPV infection are common, but the factors that lead to these false negative results are still unknown. The aim of this study was to investigate whether dogs with a false negative faecal CPV antigen ELISA result have milder clinical signs and laboratory changes, a lower faecal virus load, higher faecal and serum CPV antibody titres and a faster recovery than dogs with a positive result. Eighty dogs with CPV infection, confirmed by the presence of clinical signs and a positive faecal CPV polymerase chain reaction (PCR), were assigned to two groups according to their faecal antigen ELISA result. Time until presentation, severity of symptoms, laboratory parameters, faecal virus load, faecal and serum antibody titres, and CPV sequencing data were compared between both groups. In 38/80 dogs that were hospitalised until recovery, the time to recovery, mortality, and the course of the disease were compared between dogs with positive and negative faecal antigen ELISA results. Of the 80 dogs included, 41 (51.3%) had a false negative faecal antigen ELISA result. ELISA-negative dogs had a significantly shorter time until presentation, lower frequency of defaecation, lower faecal virus load, and higher serum antibody concentrations than ELISA-positive dogs. Laboratory changes, CPV shedding, and outcomes were not associated with faecal antigen ELISA results. In conclusion, low faecal CPV load and antibodies binding to CPV antigen in faeces are likely to be important reasons for false negative faecal antigen ELISA results. Dogs with clinical signs of CPV infection should be retested by faecal PCR. Copyright © 2015 Elsevier Ltd. All rights reserved.
Takeuchi, Masahiro; Doi, Tomomitsu; Obayashi, Kunie; Hirai, Ayako; Yoneda, Kazue; Tanaka, Fumihiro; Iwai, Yoshiko
2018-04-01
PD-L1 is one of the important immune checkpoint molecules that can be targeted by cancer immunotherapies. PD-L1 has a soluble form (sPD-L1) and a membrane-bound form (mPD-L1). Conventional enzyme-linked immunosorbent assay (ELISA) systems can detect sPD-L1 using anti-PD-L1 capture antibody through the antigen-antibody reaction, but cannot evaluate the quality and function of sPD-L1. In this study, we developed a novel ELISA system for the detection and quantification of sPD-L1 with PD-1-binding capacity (bsPD-L1). To capture bsPD-L1 through the ligand-receptor reaction, the anti-PD-L1 capture antibody in the conventional ELISA was replaced with PD-1-Ig fusion protein in the new ELISA. The new ELISA could detect bsPD-L1 in 29 out of 75 plasma samples from patients with non-small cell lung cancer (NSCLC), with higher sensitivity and frequency than the conventional ELISA. The western blot analysis showed that sPD-L1 in the plasma was glycosylated. Treatment of the samples with glycosidase reduced the absorbance determined by the new ELISA but had no effect on the absorbance determined by the conventional ELISA. These results suggest that glycosylation of sPD-L1 is important for its binding to the immobilized PD-1 in the new ELISA. Our new ELISA system may be useful for the evaluation of functional sPD-L1 with PD-1-binding capacity in cancer patients. Copyright © 2018 European Federation of Immunological Societies. Published by Elsevier B.V. All rights reserved.
Walraph, J; Zoche-Golob, V; Weber, J; Freick, M
2018-06-01
In cattle, indirect enzyme-linked immunosorbent assay (ELISA) tests are commonly used in serological routine diagnostics. In a longitudinal study design, changes in relative optical density (OD) from drying-off until week 11 after calving were analyzed in blood and milk samples from pluriparous dairy cows (n=21) using a commercial indirect anti-C. burnetii ELISA test. In a second part of this study, changes over time were evaluated in blood and milk samples of 11 of these cows in an indirect ELISA detecting anti-Bovine viral diarrhea virus (BVDV) antibodies. Regarding the cows which were still in the herd at the time of calving, blood serological qualitative changes from positive to negative or indeterminate were demonstrated in 7/20 cows (35%) for the anti-C. burnetii indirect ELISA and in 2/10 cows (20%) for the anti-BVDV indirect ELISA, respectively, during the period from 14days ante partum to calving. Relative OD in the anti-C. burnetii and the anti-BVDV indirect ELISA tests followed basically similar courses over time. In blood serum, relative OD initially increased after drying-off, before a drop around calving was observed. After the colostrum period, relative OD in blood serum showed an increase until week 11 of lactation. In colostrum samples, relative OD levels were higher than in milk samples obtained one day before drying-off. After parturition, relative OD in milk decreased until week 6 of lactation in the anti-C. burnetii indirect ELISA and until week 11 in the anti-BVDV indirect ELISA, respectively. In conclusion, blood serological investigations in periparturient dairy cows using indirect ELISA kits should be avoided. Copyright © 2018 Elsevier Ltd. All rights reserved.
Cubero, África; Durántez, Carlos; Almaraz, Ana; Fernández-Lago, Luis; Gutiérrez, María P; Castro, María J; Bratos, Miguel A; Simarro, María; March, Gabriel A; Orduña, Antonio
2018-04-01
The aim of this work was to ascertain the usefulness of a new commercially-available single-assay chemiluminescence test (CHT) for the diagnosis of human tularemia (Tularaemia VIRCLIA IgG + IgM monotest, Vircell, Santa Fe, Granada, Spain). A total of 773 sera from 773 patients including 364 initial sera from patients with diagnosed tularemia, patients with suspected tularemia not confirmed (100), healthy people (152), patients with serology positive to Brucella (97), patients diagnosed with other infectious diseases (30), and patients diagnosed with autoimmune diseases (30) were included. All sera were tested by CHT, "in-house" microagglutination test (MAT), immunochromatographic test (ICT) (Virapid Tularaemia, Vircell, Santa Fe Granada, Spain), and "in-house" ELISA IgG, and ELISA IgM. Of the total initial sera, 334 (sensitivity 91.8%) were positive in the CHT, 332 (sensitivity 91.2%) in the MAT, 330 (sensitivity 90.7%) in the ICT, and 328 (sensitivity 90.1%) in the ELISA IgG and ELISA IgM tests. The specificity of the CHT was 96.7%; of the MAT, 100%; of the ICT, 98.7%; and of the ELISA IgG and ELISA IgM, 97.4%. In the group of patients with serology positive to Brucella, at least 12.4% of sera were positive in tularemia tests (12.4% in ELISA IgM, 13.4% in MAT, 14.4% in ICT, and 15.5% in CHT and ELISA IgG). In conclusion, CHT presents a sensitivity and specificity in early diagnosis of human tularemia, similar to MAT, ICT, and ELISA IgG and ELISA IgM. Its single assay design allows lower costs, especially in areas of low endemicity or inter-epidemic periods.
Tahk, Hongmin; Lee, Min Hwa; Lee, Kang Bum; Cheon, Doo-Sung; Choi, Changsun
2011-07-01
This study aimed to develop a specific and sensitive duplex reverse transcription polymerase chain reaction enzyme-linked immunosorbent assay (duplex RT-PCR-ELISA) for hepatitis A virus (HAV) and hepatitis E virus (HEV). Duplex RT-PCR-ELISA could detect and differentiate HAV and HEV with specific probes. When ELISA technique was used to detect probe-bound RT-PCR products, duplex RT-PCR-ELISA could detect as little as 0.1 ng/μL HAV and HEV from clinical samples. Human norovirus, enterovirus, poliovirus, murine norovirus and feline calicivirus were used for the specificity test; all were negative. Therefore duplex RT-PCR-ELISA can be used for the simultaneous detection of HAV and HEV in contaminated fecal samples. Copyright © 2011 Elsevier B.V. All rights reserved.
Microchip ELISA coupled with cell phone to detect ovarian cancer HE4 biomarker in urine.
Wang, ShuQi; Akbas, Ragip; Demirci, Utkan
2015-01-01
Ovarian cancer is a leading cause of death from gynecologic cancers in the USA, and early diagnosis can potentially increase 5-year survival rate. Detection of biomarkers derived from hyperplasia of epithelial tissue by enzyme-linked immunosorbent assay (ELISA) proves to be a practical way of early diagnosis of ovarian cancer. However, ELISA is commonly performed in a laboratory setting, and it cannot be used in a clinical setting for on-site consultation. We have shown a microchip ELISA that detects HE4, an ovarian cancer biomarker, from urine using a cell phone integrated with a mobile application for imaging and data analysis. In microchip ELISA, HE4 from urine was first absorbed on the surface; the primary and secondary antibodies were subsequently anchored on the surface via immuno-reaction; and addition of substrate led to color development because of enzymatic labeling. The microchip after color development was imaged using a cell phone, and the color intensity was analyzed by an integrated mobile application. By comparing with an ELISA standard curve, the concentration of HE4 was reported on the cell phone screen. The presented microchip ELISA coupled with a cell phone is portable as opposed to traditional ELISA, and this method can facilitate the detection of ovarian cancer at the point-of-care (POC).
Liu, Shuangshuang; Li, Shasha; Zhang, Yang; Wang, Ye; Zhu, Yumeng; Wang, Bin; Chen, Zhi-Nan
2017-01-01
The immunoglobulin superfamily member CD147 is a widely expressed glycoprotein that occurs in both a membrane-spanning and soluble form. Sandwich ELISA is a powerful tool for analyzing soluble antigens. The aim of the present study was to obtain a highly specific polyclonal antibody against human CD147 that can be used for sandwich ELISA analysis. Expression of recombinant CD147 by a eukaryotic expression system was used to immunize rabbits to obtain antiserum. A highly specific polyclonal antibody that was able to detect soluble CD147 in sandwich ELISA was obtained by antigen-immunoaffinity chromatography purification. The purity of rabbit anti-CD147 polyclonal antibodies was ~99%, and ELISA analysis was able to determine the titer of the rabbit anti-CD147 polyclonal antibodies at 1:512,000. The lowest concentration of the standard CD147 antigen that the sandwich ELISA was able to detect was 31.25 pg/ml. The sandwich ELISA system was composed of anti-hepatoma HAb18 monoclonal antibodies and purified rabbit anti-CD147 polyclonal antibodies. The present study demonstrated that antigen-immunoaffinity chromatography may be a good technique for the purification of polyclonal antibodies, which may be used to detect antigen in sandwich ELISAs. PMID:28487989
Aga, D.S.; Thurman, E.M.
1993-01-01
Solid-phase extraction (SPE) and enzyme-linked immunosorbent assay (ELISA) were coupled for automated trace analysis of pristine water samples containing 2-chloro-4-ethylamino-6-isopropylamine-s-triazine (atrazine) and 2-chloro-2???,6???-diethyl-N-(methoxymethyl)acetanilide (alachlor). The isolation of the two herbicides on a C18-resin involved the selection of an elution solvent that both removes interfering substances and is compatible with ELISA. Ethyl acetate was selected as the elution solvent followed by a solvent exchange with methanol/water (20/80, % v/v). The SPE-ELISA method has a detection limit of 5.0 ng/L (5 ppt), >90% recovery, and a relative standard deviation of ??10%. The performance of a microtiter plate-based ELISA and a magnetic particle-based ELISA coupled to SPE was also evaluated. Although the sensitivity of the two ELISA methods was comparable, the precision using magnetic particles was improved considerably (??10% versus ??20%) because of the faster reaction kinetics provided by the magnetic particles. Finally, SPE-ELISA and isotope dilution gas chromatography/ mass spectrometry correlated well (correlation coefficient of 0.96) for lake-water samples. The SPE-ELISA method is simple and may have broader applications for the inexpensive automated analysis of other contaminants in water at trace levels.
Comparison of ELISA and Microscopy for detection of Cryptosporidium in stool
Sharma, Madhu; Chaudhary, Uma; Yadav, Aparna
2014-01-01
Background: Cryptosporidiosis, a diarrheal disease caused by the protozoan parasite Cryptosporidium spp. has become recognized as one of the most common causes of water borne diseases in humans. Aims and Objectives: To compare the sensitivity of ELISA and Microscopy for detection of Cryptosporidium in stool samples Materials and Methods: The study was conducted in the Department of Microbiology of PT. B.D. Sharma PGIMS Rohtak, between January 2011 to june 2011 on 50 stool samples, which were processed for detection of cryptosporidial antigen by ELISA and detection of cysts by microscopy (Modified Ziehl and Nelsen staining). Study and Design: This was a prospective study conducted in the Department of Microbiology in PT. BD Sharma, PGIMS, Rohtak, India. Result: Out of total, 50 stool samples eighteen (36%) samples were found positive for Cryptosporidium cysts by microscopy in comparison to 3(6%) stool samples which were found positive for cryptosporidial antigen by ELISA. Samples found positive with ELISA were also positive with microscopy. Sensitivity, specificity, positive predictive value and negative predictive value for ELISA was 16.7%, 100%, 100% and 68% respectively. Conclusion: The study concludes that stool microscopic Modified acid fast staining is more sensitive method than ELISA for detection of Cryptosporidium in stool samples but the specificity of ELISA was more than microscopy. PMID:25584216
Chiodini, P L; Hartley, S; Hewitt, P E; Barbara, J A; Lalloo, K; Bligh, J; Voller, A
1997-01-01
Blood donations are often wasted for lack of a satisfactory procedure to evaluate donors potentially exposed to malaria. We evaluated a commercial ELISA for the detection of antibodies to malaria and compared it with an immunofluorescent antibody test (IFAT). When 5,311 sera from routine non-exposed donors were tested, 24 (0.45%) were positive by the ELISA, using a Plasmodium falciparum antigen. Seventeen were subjected to confirmatory testing but none were positive by IFAT. Of 1,000 donors potentially exposed in endemic areas 15 (1.5%) were repeatably reactive by ELISA. 10 of these were tested by IFAT and 2 were positive. When 150 patients attending the Hospital for Tropical Diseases in London with acute malaria were tested, 73% of those infected with P. falciparum were repeatably reactive for malarial antibodies by ELISA and 56% with Plasmodium vivax. Of 88 stored clinical sera tested by both IFAT and ELISA 56 were positive by IFAT and of these 52 (93 degrees/0) were positive by ELISA. The ELISA is sufficiently sensitive and specific to screen at-risk donors. Its use could safely retrieve 40,000 red cell units currently discarded each year in Great Britain.
Detection of Fusarium verticillioides by PCR-ELISA based on FUM21 gene.
Omori, Aline Myuki; Ono, Elisabete Yurie Sataque; Bordini, Jaqueline Gozzi; Hirozawa, Melissa Tiemi; Fungaro, Maria Helena Pelegrinelli; Ono, Mario Augusto
2018-08-01
Fusarium verticillioides is a primary corn pathogen and fumonisin producer which is associated with toxic effects in humans and animals. The traditional methods for detection of fungal contamination based on morphological characteristics are time-consuming and show low sensitivity and specificity. Therefore, the objective of this study was to develop a PCR-ELISA based on the FUM21 gene for F. verticillioides detection. The DNA of the F. verticillioides, Fusarium sp., Aspergillus sp. and Penicillium sp. isolates was analyzed by conventional PCR and PCR-ELISA to determine the specificity. The PCR-ELISA was specific to F. verticillioides isolates, showed a 2.5 pg detection limit and was 100-fold more sensitive than conventional PCR. In corn samples inoculated with F. verticillioides conidia, the detection limit of the PCR-ELISA was 1 × 10 4 conidia/g and was also 100-fold more sensitive than conventional PCR. Naturally contaminated corn samples were analyzed by PCR-ELISA based on the FUM21 gene and PCR-ELISA absorbance values correlated positively (p < 0.05) with Fusarium sp. counts (CFU/g). These results suggest that the PCR-ELISA developed in this study can be useful for F. verticillioides detection in corn samples. Copyright © 2018 Elsevier Ltd. All rights reserved.
Shinozaki, Takashi; Watanabe, Ryuichi; Kawatsu, Kentaro; Sakurada, Kiyonari; Takahi, Shinya; Ueno, Ken-ichi; Matsushima, Ryoji; Suzuki, Toshiyuki
2013-01-01
We investigated the applicability of enzyme-linked immunosorbent assay (PSP-ELISA) using a monoclonal antibody against paralytic shellfish toxins (PST) for screening oysters collected at several coastal areas in Kumamoto prefecture, Japan. Oysters collected between 2007 and 2010 were analyzed by PSP-ELISA. As an alternative calibrant, a naturally contaminated oyster extract was used to quantify toxins in the oyster samples. The toxicity of the calibrant oyster extract determined by the official testing method, mouse bioassay (MBA), was 4 MU/g. Oyster samples collected over 3 years showed a similar toxin profile to the alternative standard, resulting in good agreement between the PSP-ELISA and the MBA. The PSP-ELISA method was better than the MBA in terms of sensitivity, indicating that it may be useful for earlier warning of contamination of oysters by PST in the distinct coastal areas. To use the PSP-ELISA as a screening method prior to MBA, we finally set a screening level at 2 MU/g PSP-ELISA for oyster monitoring in Kumamoto prefecture. We confirmed that there were on samples exceeding the quarantine level (4 MU/g) in MBA among samples quantified as below the screening level by the PSP-ELISA. It was concluded that the use of PSP-ELISA could reduce the numbers of animals needed for MBA testing.
Analysis of High-Throughput ELISA Microarray Data
DOE Office of Scientific and Technical Information (OSTI.GOV)
White, Amanda M.; Daly, Don S.; Zangar, Richard C.
Our research group develops analytical methods and software for the high-throughput analysis of quantitative enzyme-linked immunosorbent assay (ELISA) microarrays. ELISA microarrays differ from DNA microarrays in several fundamental aspects and most algorithms for analysis of DNA microarray data are not applicable to ELISA microarrays. In this review, we provide an overview of the steps involved in ELISA microarray data analysis and how the statistically sound algorithms we have developed provide an integrated software suite to address the needs of each data-processing step. The algorithms discussed are available in a set of open-source software tools (http://www.pnl.gov/statistics/ProMAT).
Yan, B; Ma, J-Z; Yu, T-F; Shao, S-L; Li, M; Fan, X-D
2014-12-01
The aim of this study was to develop an indirect enzyme-linked immunosorbent assay (i-ELISA) based on epitope AA503-509 (RANEPKE), which is on nonstructural protein of Muscovy duck parvovirus (MDPV). Sera (100) from negative and vaccinated Muscovy ducks were compared with infected sera (240) to establish the cut-off value of this i-ELISA. There was a significant difference between the positive and negative populations (P < 0·05). The adoption of this positive-negative threshold value for this i-ELISA assay resulted in specificity of 98·0%. This i-ELISA could be used as a diagnostic tool for differentiating infected Muscovy ducks from Muscovy ducks vaccinated with inactivated virus. In this study, we developed an i-ELISA based on epitope AA503-509 (RANEPKE), which is on nonstructural protein of MDPV. This i-ELISA could be used as a diagnostic tool for differentiating infected Muscovy ducks from Muscovy ducks vaccinated with inactivated virus. © 2014 The Society for Applied Microbiology.
Constraining stellar binary black hole formation scenarios with eLISA eccentricity measurements
NASA Astrophysics Data System (ADS)
Nishizawa, Atsushi; Sesana, Alberto; Berti, Emanuele; Klein, Antoine
2017-03-01
A space-based interferometer such as the evolved Laser Interferometer Space Antenna (eLISA) could observe a few to a few thousands of progenitors of black hole binaries (BHBs) similar to those recently detected by Advanced LIGO. Gravitational radiation circularizes the orbit during inspiral, but some BHBs retain a measurable eccentricity at the low frequencies where eLISA is the most sensitive. The eccentricity of a BHB carries precious information about its formation channel: BHBs formed in the field, in globular clusters, or close to a massive black hole (MBH) have distinct eccentricity distributions in the eLISA band. We generate mock eLISA observations, folding in measurement errors, and using a Bayesian model selection, we study whether eLISA measurements can identify the BHB formation channel. We find that a handful of observations would suffice to tell whether BHBs were formed in the gravitational field of an MBH. Conversely, several tens of observations are needed to tell apart field formation from globular cluster formation. A 5-yr eLISA mission with the longest possible armlength is desirable to shed light on BHB formation scenarios.
Stelzer-Braid, Sacha; Wong, Bruce; Robertson, Peter; Lynch, Garry W; Laurie, Karen; Shaw, Robert; Barr, Ian; Selleck, Paul W; Baleriola, Cristina; Escott, Ros; Katsoulotos, Gregory; Rawlinson, William D
2008-10-01
Commercial serological assays to determine influenza A H5N1 infection are available, although the accuracy and reproducibility of these are not reported in detail. This study aimed to assess the validity of a commercial ELISA H5 hemagglutinin (HA) antibody kit. A commercial ELISA for detection of antibodies towards influenza A H5 HA was evaluated using human sera from vaccinated individuals. The ELISA was used to screen 304 sera with elevated influenza A complement fixation titres collected between the period 1995-2007. The ELISA was found to be accurate for sera with high levels of anti-H5 antibodies, and would be useful in clinical settings where a rapid result is required. Thirteen of the stored sera were positive using the ELISA, but were confirmed as negative for H5N1 exposure using further serological tests. Absorption studies suggested that antibodies towards seasonal H3N2 and H1N1 influenza may cross-react with H5 antigen, giving false positive results with the ELISA.
Collins, Á B; Grant, J; Barrett, D; Doherty, M L; Hallinan, A; Mee, J F
2017-08-01
Schmallenberg virus (SBV) is transmitted by Culicoides spp. biting midges and can cause abortions and congenital malformations in ruminants and milk drop in dairy cattle. Estimating true within-herd seroprevalence is an essential component of efficient and cost-effective SBV surveillance programs. The objectives of this study were: (1) determine the correlation between bulk-tank milk (BTM)-ELISA results and within-herd seroprevalence, (2) evaluate the ability of BTM-ELISA results to predict within-herd seroprevalence and (3) explore the distributions of individual animal serology results using novel statistical methodology. BTM samples (n=24) and blood samples (n=4019) collected from all lactating cows contributing to the BTM in 26 Irish dairy herds (58-444 cows/herd) in 2014 located in a region exposed to SBV in 2012/2013, were analysed for SBV-specific antibodies using IDVet ® ELISA kits. The correlation between BTM-ELISA results and within-herd seroprevalence was determined by calculating Pearson's correlation coefficient. Linear regression models were used to assess the ability of BTM-ELISA results to predict within-herd seroprevalence. The distributions of individual animal serology results were explored by determining the empirical distribution functions (EDF) of the individual animal serum ELISA results in each herd. EDFs were compared pairwise across herds, using the Kolmogorov-Smirnov statistical test. Herds with similar BTM-ELISA results, herds with similar within-herd seroprevalence and herds with similar mean-herd serology ELISA results were stratified in order to explore their respective paired-herd EDF comparisons. Statistical significance was set at p<0.05. Twenty-two herds were BTM-ELISA-positive (within-herd seroprevalence 30.6-100%) and two herds were BTM-ELISA-negative (within-herd seroprevalence 10.7 and 16.2%) indicating BTM-ELISA-negative herds can have seropositive animals present. BTM-ELISA results were highly correlated (r=0.807, p<0.0001) with, and predictive of (R 2 =0.832, p<0.0001) of within-herd seroprevalence. Predictions were most accurate for upper-range BTM-ELISA antibody titres, while they were less accurate at higher and lower antibody titres. This is likely a result of the overall high within-herd seroprevalence. In herds with similar BTM-ELISA results 82% of the paired-herd EDF comparisons were significantly different. In herds with similar within-herd seroprevalence and in herds with similar mean-herd serology ELISA results, 46% and 47% of the paired-herd EDF comparisons were significantly different, respectively. These results demonstrate that BTM antibody titres are highly predictive of within-herd seroprevalence in an SBV exposed region. Furthermore, exploring the serum EDFs revealed that the variation observed in the predicted within-herd seroprevalence in the regression models is likely a result of individual animal variation in serum antibody titres in these herds. Copyright © 2017 Elsevier B.V. All rights reserved.
Detection of Penicillinase in Milk by Sandwich ELISA Based Polyclonal and Monoclonal Antibody.
Zhao, Yinli; Li, Guoxi
2016-01-01
A sandwich ELISA has been developed using polyclonal and monoclonal antibody for the determination of penicillinase in milk. For this purpose, specific polyclonal and monoclonal antibodies against penicillinase were generated and characterized. Using penicillinase standards prepared from 1-128 ng/mL, the method indicated that the detection limit of the sandwich ELISA, as measured in an ELISA plate reader, was as low as 0.86 ng/mL of penicillinase. For determine the accuracy, raw milk containing 2, 8, 32, and 64 ng/mL of penicillinase were tested by sandwich ELISA. Recoveries were from 93-97.5%, and the coefficient of variation [CV (%)] were from 5.55-8.38%. For interassay reproducibility, recoveries were from 89.5-95.1%, the coefficient of variation [CV (%)] were from 5.26-9.58%. This sandwich ELISA provides a useful screening method for quantitative detection of penicillinase in milk.
Schwarz, Norbert Georg; Mertens, Eva; Winter, Doris; Maiga-Ascofaré, Oumou; Dekker, Denise; Jansen, Stephanie; Tappe, Dennis; Randriamampionona, Njary; May, Jürgen; Rakotozandrindrainy, Raphael; Schmidt-Chanasit, Jonas
2017-01-01
It was previously reported that a malaria infection may interfere with the specificity of a commercial ELISA test against Zika virus (ZIKV). We analyzed 1,216 plasma samples from healthy, pregnant women collected in two sites in Madagascar in 2010 for ZIKV antibodies using a commercial ELISA and for Plasmodium infection by PCR. This screen revealed six putative ZIKV-positive samples by ELISA. These results could not be confirmed by indirect immunofluorescence assays or virus neutralization tests. Four of these six samples were also positive for P. falciparum. We noted that the frequency of malaria positivity was higher in ZIKV-ELISA positive samples (50% and 100% in the two study sites) than ZIKV-negative samples (17% and 10%, respectively), suggesting that malaria may have led to false ZIKV-ELISA positives.
Pollard, S J T; Farmer, J G; Knight, D M; Young, P J
2002-01-01
Commercial mono- and polyclonal enzyme-linked immunosorbent assay (ELISA) systems were applied to the on-site analysis of weathered hydrocarbon-contaminated soils at a former integrated steelworks. Comparisons were made between concentrations of solvent extractable matter (SEM) determined gravimetrically by Soxhlet (dichloromethane) extraction and those estimated immunologically by ELISA determination over a concentration range of 2000-330,000 mg SEM/kg soil dry weight. Both ELISA systems tinder-reported for the more weathered soil samples. Results suggest this is due to matrix effects in the sample rather than any inherent bias in the ELISA systems and it is concluded that, for weathered hydrocarbons typical of steelworks and coke production sites, the use of ELISA requires careful consideration as a field technique. Consideration of the target analyte relative to the composition of the hydrocarbon waste encountered appears critical.
Optimization and Validation of ELISA for Pre-Clinical Trials of Influenza Vaccine.
Mitic, K; Muhandes, L; Minic, R; Petrusic, V; Zivkovic, I
2016-01-01
Testing of every new vaccine involves investigation of its immunogenicity, which is based on monitoring its ability to induce specific antibodies in animals. The fastest and most sensitive method used for this purpose is enzyme-linked immunosorbent assay (ELISA). However, commercial ELISA kits with whole influenza virus antigens are not available on the market, and it is therefore essential to establish an adequate assay for testing influenza virusspecific antibodies. We developed ELISA with whole influenza virus strains for the season 2011/2012 as antigens and validated it by checking its specificity, accuracy, linearity, range, precision, and sensitivity. The results show that we developed high-quality ELISA that can be used to test immunogenicity of newly produced seasonal or pandemic vaccines in mice. The pre-existence of validated ELISA enables shortening the time from the process of vaccine production to its use in patients, which is particularly important in the case of a pandemic.
Oral rapid test: an alternative to traditional HIV screening in Chile
Irarrazábal, Lisette Paola; Ferrer, Lilian; Cianelli, Rosina; Lara, Loreto; Reed, Reiley; Levy, Judith; Pérez, Carlos
2016-01-01
Objective To compare the sensitivity and specificity of an Oral Rapid Test (ORT) to that of the Enzyme-Linked Immunosorbent Assay (ELISA) for HIV testing in Santiago, Chile; to track the number of study participants returning for ELISA testing results; and to analyze the participants’ perceptions of the ORT compared to the ELISA. Methods A total of 497 people were recruited in Santiago, Chile: 153 had previously tested positive for HIV, and 344 were of unknown status. Participants were tested for HIV using both the ELISA and the ORT to examine and compare specificity and sensitivity. Qualitative data were collected from 22 participants to compare perceptions of the testing experience with ORT versus ELISA. Results The ELISA reported 184 (37%) of the 497 participants as being “positive” for HIV antibodies; the ORT showed 181 (36.4%) as being “reactive” for HIV. The ORT showed a sensitivity of 98.4% (95.7%–99.9%, 95% Confidence Interval) and specificity of 100%. The Kappa test produced K = 0.983 (P < 0.0001). Of the 344 participants whose HIV status was unknown at the start of the study, 55 failed to return for their ELISA results. Participants positively perceived ORT as having reduced both waiting time and anxiety over obtaining their test results. ORT oral swabbing appeared more practical and less invasive than drawing blood for the ELISA. Conclusions The ORT and ELISA were statistically equal in specificity and sensitivity. ORT provides quicker results, potentially ensuring that more people receive them, and does not require handling of or exposure to potentially hazardous blood products. PMID:23939368
Butler, J E; McGivern, P L; Swanson, P
1978-01-01
A modification of the standard enzyme-linked immunosorbent assay (ELISA) is described which circumvents the requirement for specifically purified antibodies from which antibody-enzyme complexes are made. The assay utilizes the principle of a soluble anti-alkaline phosphatase immune complex (AP-A-AP) and has been called the amplified ELISA. Methods for preparing and evidence for the specificity of rabbit anti-rat gamma-FC, IgM (mu) and IgA (alpha) are presented. These reagents are used to measure anti-DNP antibodies belonging to classes IgG, IgM and IgA in rat serum. Using antiglobulin and anti-enzyme reagents prepared in guinea pigs, anti-ovalbumin antibodies are measured in rabbit serum. Titration curves are similar when the amplified ELISA is compared to the standard ELISA. A change in slope suggesting an effect of saturation of antigen sites, occurs at the same input antibody concentration for both assays. Determination of the anti-DNP concentration of unknown sera by extrapopulation from titration graphs of a known serum suggests that the value is overestimated, i.e., amplified when the amplified ELISA is used. In addition, the amplified ELISA has an improved ability to detect low levels of antibody. Evidence is presented which illustrates how the use of optimally conjugated DNP-proteins, age of conjugates, and optimal dilutions of secondary antiglobulins and the AP-A-AP reduce non-specific binding in the amplified ELISA. The amplified ELISA is capable of detecting 2.4 ng of antibody to ovalbumin in a one: one million dilution of rabbit serum with high reproducibility and low background.
Dhaliwal, G S; Murray, R D; Dobson, H; Montgomery, J; Ellis, W A
1996-03-01
Samples of cervico-vaginal mucus from 163 bulling cows (group 1) and post calving discharges from 59 newly calved cows (group 2) in five dairy herds naturally infected with Leptospira interrogans serovar hardjo were examined for the presence of antigen and IgG and IgA antibodies by using two ELISA systems which were protein or carbohydrate based. Corresponding serum samples were examined for systemic immune responses by using a microscopic agglutination test (MAT) and IgG-ELISA tests. Antigen was detected by direct immunofluorescence in six of the 163 samples of cervico-vaginal mucus. Both IgG and IgA antibodies were detected by ELISA in the genital discharges with a prevalence much higher than that obtained by the MAT but lower than that observed with the serum IgG-ELISA. Combining both groups, none of the MAT-positive cattle was negative by serum-ELISA. By using the protein or carbohydrate fraction serum IgG-ELISA assays, respectively, 29 or 41 per cent of the MAT-negative cows were positive at a titre of at least 1:40. Similarly, eight or 23 samples (10 or 27 per cent) had titres of at least 1:20 in the genital discharge ELISA for IgG and IgA antibodies, respectively. The serum IgG-ELISA was the most efficient in detecting hardjo antibodies, but in group 2 the IgG- and IgA-ELISA of the post calving discharge proved to be equally effective.
Expression of Molecular Markers in Brain, Serum, and Lung Tissues Following Hypobaric Hypoxia
2018-01-01
8 4.2 HIF-1α ELISA Results...9 4.3 Prolyl-4-hydroxylase Alpha Polypeptide I (P4Ha1) ELISA Results...10 4.4 Vascular Endothelial Growth Factor ELISA Results .......................................................12
Hirose, Orie; Itabashi, Mitsuyo; Takei, Takashi; Nitta, Kosaku
2015-03-01
Myeloperoxidase (MPO) anti-neutrophil cytoplasmic antibody (ANCA) represents the serological hallmark of ANCA-associated vasculitis (AAV). We evaluated the analytical and diagnostic accuracy of chemiluminescence enzyme immunoassay (CLEIA) versus enzyme-linked immunosorbent assay (ELISA) for the detection of MPO-ANCA. A total of 242 sera obtained from 51 patients with AAV and 103 patients without AAV were tested for MPO-ANCA by ELISA (NephroScholor MPOANC II) and CLEIA (the STACIA MEBLux test). Disease activity in the patients with AAV was determined based on the Birmingham Vasculitis Activity Score. We analyzed the correlations between the MPO-ANCA titers determined by the CLEIA and those determined by the ELISA, and also between the MPO-ANCA titers and the disease activity. The MPO-ANCA titers determined by the CLEIA (x) were strongly correlated with those determined by the ELISA (y). The correlation could be expressed by the following equation in this study: y = 1.8x + 7.7 (r = 0.96; p < 0.0001). At the cutoff value of 3.5 U/ml, the CLEIA yielded positive test results for MPO-ANCA in 73 of the 242 sera (30.2%), while at the cutoff value of 20 U/ml, ELISA yielded positive test results in 57 of the 242 sera (23.6%). The CLEIA yielded false-positive test results in 4 of the 120 sera obtained from the non-AAV patients (3.3%), whereas the ELISA yielded a false-positive result in only 1 of the 120 sera obtained from the non-AAV patients (0.8%). The sensitivity and specificity of the CLEIA for the diagnosis of AAV were 100% and 96.7%, respectively, while those of the ELISA were 94.3% and 99.2%, respectively. The sensitivity and specificity of the CLEIA for the prediction of active disease were 100% and 64.4%, respectively, while those of the ELISA were 94.3% and 73.6%, respectively. The false positivity rate of the CLEIA for MPO-ANCA tended to be high as compared with that of the ELISA. Also, according to the correlation coefficient between the results of the CLEIA and the ELISA calculated in this study, it is necessary to pay attention to the differences in the sensitivity and specificity between CLEIA and ELISA.
Marangoni, Antonella; Sparacino, Monica; Cavrini, Francesca; Storni, Elisa; Mondardini, Valeria; Sambri, Vittorio; Cevenini, Roberto
2005-04-01
In this study the raising and development of the immune response to Borrelia burgdorferi infection in 45 Italian patients suffering from culture-confirmed Lyme borreliosis erythema migrans was investigated. A total of 95 serially collected serum samples were tested by using three different commercial ELISAs: recomWell Borrelia (Mikrogen), Enzygnost Borreliosis (DADE Behring) and Quick ELISA C6 Borrelia (Immunetics). The sensitivities of the ELISAs were as follows: Enzygnost Borreliosis IgM, 70.5 %; Quick ELISA C6 Borrelia, 62.1 %; recomWell Borrelia IgM, 55.7 %; recomWell Borrelia IgG, 57.9 %; and Enzygnost Borreliosis IgG, 36.8 %. In order to compare the specificity values of the three ELISAs, a panel of sera obtained from blood donors (210 samples coming from a non-endemic area and 24 samples from an endemic area) was tested, as well as sera from patients suffering from some of the most common biological conditions that could result in false-positive reactivity in Lyme disease serology (n = 40). RecomWell Borrelia IgG and recomWell Borrelia IgM were the most specific (97.1 % and 98.9 %, respectively), followed by Quick ELISA C6 Borrelia (96.7 %). Enzygnost Borreliosis IgG and IgM achieved 90.1 % and 92.3 % specificity, respectively. Sera that gave discrepant results when tested by the three ELISAs were further analysed by Western blotting.
Tawfeek, Gihan M; Elwakil, Hala S; El-Hoseiny, Laila; Thabet, Hala S; Sarhan, Rania M; Awad, Nabil S; Anwar, Wagida A
2011-02-01
The diagnosis of patients with cystic echinococcosis (CE) by means of serology has a limited support in clinical practice due to cross-reactivity with other helminthes leading to overestimation of the parasite's true prevalence. A wealth of reports on the diagnostic performance of antigen B (AgB) has been produced. This study was designed to comparatively assess the diagnostic efficacy of crude sheep hydatid cyst fluid (HCF), AgB and its subunit (12 KDa) to detect IgG or IgG4 antibodies in CE patients' sera using enzyme-linked immunosorbent assay (ELISA).The best diagnostic performance was obtained with anti-HCF IgG ELISA which gave 92.4% sensitivity and 92.6% specificity. Despite the low sensitivity of anti AgB IgG ELISA (84%), it gave the best specificity (94.4%) with less cross-reaction with sera of subjects infected with other parasites. In conclusion, it is recommended to use anti-HCF IgG ELISA for initial screening in large seroprevalence studies. Further analysis of positive serum samples with anti AgB IgG ELISA would allow the confirmation of true positives. Specific IgG4 ELISA may represent a complementary assay, useful as secondary confirmatory tests for patients with suspected CE and negative for total IgG ELISA.
Analysis of fenbendazole residues in bovine milk by ELISA.
Brandon, David L; Bates, Anne H; Binder, Ronald G; Montague, William C; Whitehand, Linda C; Barker, Steven A
2002-10-09
Fenbendazole residues in bovine milk were analyzed by ELISAs using two monoclonal antibodies. One monoclonal antibody (MAb 587) bound the major benzimidazole anthelmintic drugs, including fenbendazole, oxfendazole, and fenbendazole sulfone. The other (MAb 591) was more specific for fenbendazole, with 13% cross-reactivity with the sulfone and no significant binding to the sulfoxide metabolite. The limit of detection of the ELISA method in the milk matrix was 7 ppb for MAb 587 and 3 ppb for MAb 591. Fenbendazole was administered in feed, drench, and paste form to three groups of dairy cattle. Milk was collected immediately before dosing and then every 12 h for 5 days. The ELISA indicated that residue levels varied widely among individual cows in each group. Fenbendazole levels peaked at approximately 12-24 h and declined rapidly thereafter. Metabolites were detected at much higher levels than the parent compound, peaked at approximately 24-36 h, and declined gradually. Residue levels were undetectable by 72 h. The ELISA data correlated well with the total residues determined by chromatographic analysis, but the use of the two separate ELISAs did not afford an advantage over ELISA with the single, broadly reactive MAb 587. The ELISA method could be used to flag high-residue samples in on-site monitoring of fenbendazole in milk and is a potential tool for studying drug pharmacokinetics.
Snyder, M H; Banks, S; Murphy, B R
1988-01-01
We modified an existing enzyme-linked immunosorbent assay (ELISA) to be able to use new spectrophotometers which can measure the rate of color development in microtiter wells. This new kinetic-based ELISA (KELISA) required only a single dilution of specimen rather than the multiple dilutions required with endpoint ELISA. In addition, 10- to 100-fold-less specimen was required to perform the KELISA than the ELISA. The level of serum or nasal wash antibody against surface glycoproteins of influenza A or influenza B viruses determined by KELISA was reproducible and correlated highly with the results of endpoint ELISA or hemagglutination inhibition tests. The difference between the KELISA rates, which indicated than an antibody response to infection had occurred, was defined and was analogous to a 2.2-fold rise in titer for serum and a 3.4-fold rise in titer for nasal wash determined by endpoint ELISA. The KELISA was similar to endpoint ELISAs in its ability to detect rises in antibody level in paired serum or nasal wash specimens obtained from volunteers who received live attenuated influenza A reassortant virus vaccines. By eliminating the need for multiple dilutions, the use of KELISA offers the advantage of increasing the number of assays that can be performed by the same personnel compared with endpoint ELISA, while it maintains sensitivity and specificity. PMID:3182992
Gono, Takahisa; Okazaki, Yuka; Murakami, Akihiro; Kuwana, Masataka
2018-04-09
To compare the quantitative performance for measuring anti-MDA5 antibody titer of two enzyme-linked immunosorbent assay (ELISA) systems: an in-house ELISA and the commercial MESACUP TM anti-MDA5 test. Anti-MDA5 antibody titer was measured in sera from 70 patients with dermatomyositis using an in-house ELISA and the MESACUP TM anti-MDA5 test side-by-side. For the commercial ELISA kit, serum samples diluted 1:101 were used according to the manufacturer's protocol, but serial dilutions of sera were also examined to identify the optimal serum dilution for quantification. The anti-MDA5 antibody titers measured by the in-house and commercial ELISAs were positively correlated with each other (r = 0.53, p = .0001), but the antibody titer measured by the commercial ELISA was less sensitive to change after medical treatment, and 37 (80%) of 46 anti-MDA5-positive sera had antibody titer exceeding the quantification range specified by the manufacturer (≥150 index). Experiments using diluted serum samples revealed that diluting the sera 1:5050 improved the quantitative performance of the MESACUP TM anti-MDA5 test, including a better correlation with the in-house ELISA results and an increased sensitivity to change. We improved the ability of the commercial ELISA kit to quantify anti-MDA5 antibody titer by altering its protocol.
Mosadeghi, Parvin; Heydari-Zarnagh, Hafez
2018-04-01
We aimed to develope a peptide-based indirect ELISA to detect antibodies against Human T-lymphotropic virus type I (HTLV-I). Two chimeric peptides (CP-1 and CP-2) were designed using linear immunodominant epitopes of gp-46-I, and gp21-I proteins, according to the sequence from Uniprot database. These peptides were studied initially in the ELISA using infected sera. The most promising peptideCP-1, was used to develop a peptide ELISA for detection of HTLV-I infected sera. The optimal conditions for CP-1ELISA were: the optimum coating buffer was 100mM NaHCO3, pH 9.6; coating peptide concentration was 10 µg/mL; the optimal blocking buffer was5% fetal bovine serum (FBS); the secondary antibody concentration was 1:2000; and serum dilution was 1:20. 20serum samples from HTLV-I infected patients were evaluated by ELISA developed. CP-1 showed high antigenicity while lacking any cross-reactivity with normal human sera. The results of evaluations indicated that in comparison with commercial ELISA, CP-1 ELISA showed good sensitivity and specificity. With further validation, CP-1as described in the present study could be introduced as novel reliable and cost-effective candidates for the high-specific screening of HTLV-I/-II infections in endemic regions.
Thiha, Aung; Ibrahim, Fatimah
2015-05-18
The enzyme-linked Immunosorbent Assay (ELISA) is the gold standard clinical diagnostic tool for the detection and quantification of protein biomarkers. However, conventional ELISA tests have drawbacks in their requirement of time, expensive equipment and expertise for operation. Hence, for the purpose of rapid, high throughput screening and point-of-care diagnosis, researchers are miniaturizing sandwich ELISA procedures on Lab-on-a-Chip and Lab-on-Compact Disc (LOCD) platforms. This paper presents a novel integrated device to detect and interpret the ELISA test results on a LOCD platform. The system applies absorption spectrophotometry to measure the absorbance (optical density) of the sample using a monochromatic light source and optical sensor. The device performs automated analysis of the results and presents absorbance values and diagnostic test results via a graphical display or via Bluetooth to a smartphone platform which also acts as controller of the device. The efficacy of the device was evaluated by performing dengue antibody IgG ELISA on 64 hospitalized patients suspected of dengue. The results demonstrate high accuracy of the device, with 95% sensitivity and 100% specificity in detection when compared with gold standard commercial ELISA microplate readers. This sensor platform represents a significant step towards establishing ELISA as a rapid, inexpensive and automatic testing method for the purpose of point-of-care-testing (POCT) in resource-limited settings.
Zhuo, Xunhui; Sun, Hongchao; Zhang, Zhi; Luo, Jiaqing; Shan, Ying; Du, Aifang
2017-06-01
Serologic tests are widely accepted and applied as means to detect anti- Toxoplasma gondii immunoglobulin G antibodies. In this study, recombinant matrix antigen (rMAG1) was induced by isopropyl-β-d-thiogalactoside and purified by nickel-nitrilotriacetic acid purification system. We then developed and optimized an indirect enzyme-linked immunosorbent assay (ELISA) through checkerboard assays using serial dilutions of antigens and sera to assess the potential use of rMAG1 in serologic detection of T. gondii infection in dogs. Serum samples from 93 domestic dogs were analyzed by western blot and rMAG1-ELISA. The results were compared with those obtained from an ELISA with the soluble Toxoplasma lysate antigens (TLA). We found that although yielding an excellent agreement (96.7%) with western blot data (κ = 0.9659), rMAG1-ELISA produced higher sensitivity (93.9% vs. 87.8%) and specificity (98.3% vs. 96.7%) than TLA-ELISA. In addition, receiver operating characteristic analysis also revealed that rMAG1-ELISA is in more agreement with western blot (area under the curve [AUC] = 0.985) relative to TLA-ELISA (AUC = 0.955). These results indicated that the rMAG1-ELISA established in this study provides a promising and reliable tool for serologic detection of T. gondii infection in dogs.
Ivens, Katherine O; Baumert, Joseph L; Hutkins, Robert L; Taylor, Steve L
2017-11-01
Milk and milk products are among the most important allergenic food ingredients, both in the United States and throughout the world; cheeses are among the most important of these milk products. Milk contains several major antigenic proteins, each with differing susceptibilities to proteolytic enzymes. The extent of proteolysis in cheese varies as a result of conditions during manufacture and ripening. Proteolysis has the potential to degrade antigenic and allergenic epitopes that are important for residue detection and elicitation of allergic reactions. Commercial enzyme-linked immunosorbent assays (ELISAs) are not currently validated for use in detecting residues in hydrolyzed or fermented food products. Eighteen retail cheeses produced using 5 different styles of fermentation were investigated for detectable milk protein residues with 4 commercial ELISA kits. Mozzarella, Swiss, Blue, Limburger, and Brie cheeses were assessed. The Neogen Veratox® Casein and Neogen Veratox® Total Milk kits were capable of detecting milk residues in most cheeses evaluated, including blue-veined cheeses that exhibit extensive proteolysis. The other 2 ELISA kits evaluated, r-Biopharm® Fast Casein and ELISA Systems™ Casein, can detect milk residues in cheeses other than blue-veined varieties. ELISA results cannot be quantitatively compared among kits. The quantitative reliability of ELISA results in detection of cheese residues is questionable, but some methods are sufficiently robust to use as a semi-quantitative indication of proper allergen control for the validation of cleaning programs in industry settings. Many commercially available enzyme-linked immunosorbent assays (ELISAs) are not validated for detection of allergenic residues in fermented or hydrolyzed products. This research seeks to determine if commercial milk ELISAs can detect milk residues in varieties of cheese that have undergone different styles of fermentation and different degrees of proteolysis. Only certain milk ELISA kits are capable of detecting residues in all varieties of cheese. However, commercial milk ELISA kits are capable of semiquantitative detection of cheese residues in foods, or in industry settings for the validation of allergen cleaning programs. © 2017 Institute of Food Technologists®.
van Gorkom, T; Kremer, K; Voet, W; Notermans, D W; Vlaminckx, B J M; Sankatsing, S U C; Thijsen, S F T
2017-11-01
The diagnosis of Lyme borreliosis is challenging because of the often non-specific symptoms and persisting antibodies after infection. We investigated the diagnostic characteristics of two enzyme-linked immunosorbent assays (ELISAs) and an immunoblot for the detection of Borrelia-specific serum antibodies using different test strategies in individuals with and without antibiotic treatment for Lyme borreliosis. This retrospective study included healthy individuals, patients with active Lyme neuroborreliosis and patients treated for Lyme neuroborreliosis. Two ELISAs were compared: the C6 ELISA and the SERION ELISA. Equivocal and positive results were confirmed by immunoblot. We included 174 healthy individuals, of whom 27 (15.5%) were treated for Lyme borreliosis in the past, 36 patients were treated for Lyme neuroborreliosis and 27 patients had active Lyme neuroborreliosis. All the active Lyme neuroborreliosis patients were reactive in both ELISAs (100% sensitivity); less reactivity was seen in the other three groups (range 17.7% to 69.4%). The concordance between the ELISA results was high in active Lyme neuroborreliosis patients (26/27; 96.3%) and healthy individuals (131/147; 89.1%), but lower in treated healthy individuals (18/27; 66.7%) and treated Lyme neuroborreliosis patients (18/36; 50.0%) (p ≤ 0.005). This study showed that antibiotic treatment against Lyme borreliosis was strongly associated with discordant ELISA and test strategy results (odds ratio: 10.52; p < 0.001 and 9.98; p = 0.014, respectively) suggesting antibiotic treatment influences the pace at which the various antibodies directed to the different antigens used in both ELISAs wane. Among treated neuroborreliosis patients, the SERION ELISA stayed positive for a longer period after infection compared to the C6 ELISA. This should be taken into consideration when requesting and/or interpreting Lyme serology.
Yeargan, Michelle; de Assis Rocha, Izabela; Morrow, Jennifer; Graves, Amy; Reed, Stephen M; Howe, Daniel K
2015-05-01
Enzyme-linked immunosorbent assays (ELISAs) based on the SnSAG surface antigens of Sarcocystis neurona provide reliable detection of infection by the parasite. Moreover, accurate serodiagnosis of equine protozoal myeloencephalitis (EPM) is achieved with the SnSAG ELISAs by measuring antibodies in serum and cerebrospinal fluid (CSF) to reveal active infection in the central nervous system. Two independent ELISAs based on recombinant (r)SnSAG2 or a chimeric fusion of SnSAG3 and SnSAG4 (rSnSAG4/3) are currently used together for EPM serodiagnosis to overcome varied antibody responses in different horses. To achieve reliable antibody detection with a single ELISA instead of 2 separate ELISAs, rSnSAG2 was fused with rSnSAG4/3 into a single trivalent protein, designated rSnSAG2/4/3. Paired serum and CSF from 163 horses were tested with all 3 ELISAs. When the consensus antibody titers obtained with the rSnSAG2 and rSnSAG4/3 ELISAs were compared to the single SAG2/4/3 ELISA titers, Spearman rank correlation coefficients of ρ = 0.74 and ρ = 0.90 were obtained for serum and CSF, respectively, indicating strong agreement between the tests. When the rSnSAG2 and rSnSAG4/3 consensus serum-to-CSF titer ratio was compared to the rSnSAG2/4/3 serum-to-CSF titer ratio, the Spearman correlation coefficient was ρ = 0.87, again signifying strong agreement. Importantly, comparing the diagnostic interpretation of the serum-to-CSF titer ratios yielded a Cohen kappa value of 0.77. These findings suggest that the single ELISA based on the trivalent rSnSAG2/4/3 will provide serologic and diagnostic results that are highly comparable to the consensus of the 2 independent ELISAs based on rSnSAG2 and rSnSAG4/3. © 2015 The Author(s).
Curry, Patricia S; Ribble, Carl; Sears, William C; Hutchins, Wendy; Orsel, Karin; Godson, Dale; Lindsay, Robbin; Dibernardo, Antonia; Kutz, Susan J
2014-04-01
We compared Nobuto filter paper (FP) whole-blood samples to serum for detecting antibodies to seven pathogens in reindeer (Rangifer tarandus tarandus). Serum and FP samples were collected from captive reindeer in 2008-2009. Sample pairs (serum and FP eluates) were assayed in duplicate at diagnostic laboratories with the use of competitive enzyme-linked immunosorbent assays (cELISAs) for Neospora caninum and West Nile virus (WNV); indirect ELISA (iELISAs) for bovine herpesvirus type 1 (BHV-1), parainfluenza virus type 3 (PI-3), and bovine respiratory syncytial virus (BRSV); and virus neutralization (VN) for bovine viral diarrhea virus (BVDV) types I and II. Assay thresholds were evidence-based values employed by each laboratory. Comparable performance to serum was defined as FP sensitivity and specificity ≥ 80%. Filter-paper specificity estimates ranged from 92% in the cELISAs for N. caninum and WNV to 98% in the iELISAs for PI-3 and BRSV. Sensitivity was >85% for five tests (most ≥ 95%) but was insufficient (71-82%) for the PI-3 and BRSV iELISAs. Lowering the threshold for FP samples in these two ELISAs raised sensitivity to ≥ 87% and reduced specificity slightly (≥ 90% in three of the four test runs). Sample size limited the precision of some performance estimates. Based on the criteria of sensitivity and specificity ≥ 80%, and using adjusted FP thresholds for PI-3 and BRSV, FP sensitivity and specificity were comparable to serum in all seven assays. A potential limitation of FP is reduced sensitivity in tests that require undiluted serum (i.e., N. caninum cELISA and BVDV VNs). Possible toxicity to the assay cell layer in VN requires investigation. Results suggested that cELISA is superior to iELISA for detecting antibodies in FP samples from reindeer and other Rangifer tarandus subspecies. Our findings expand the potential utility of FP sampling from wildlife.
Khamehchian, S; Madani, R; Rasaee, M J; Golchinfar, F; Kargar, R
2007-06-01
A competitive enzyme-linked immunosorbent assay (C-ELISA) has been developed and standardized for the detection of antibodies to the rinderpest virus (RPV) in sera from cattle, sheep, and goats. The test is specific for rinderpest because it does not detect antibodies to peste-des-petits-ruminants virus (PPRV). The test depends on the ability of the monoclonal antibody (MAb) directed against the hemagglutinin (H) protein of RPV to compete with the binding of RPV antibodies in the positive serum to the H protein of this virus. This MAb recognized a region from amino acids 575 to 583 on the H protein of RPV that is unique to the RPV H protein and is not present on the hemagglutinin-neuraminidase protein of PPRV. Another C-ELISA (peptide C-ELISA) was set up using this specific region as an antigen. A threshold value of 64.4% inhibition was established for the RPV C-ELISA, with 90 known RPV-negative and 30 RPV-positive serum samples. Using common serum samples, a cutoff value of 43.0% inhibition for the peptide C-ELISA was established. Based on statistical analysis, the overall sensitivity and specificity of the RPV C-ELISA, relative to those of a commercial kit, were found to be 90.00% and 103.33%, respectively. However, the sensitivity and specificity of the peptide C-ELISA were found to be 180.00% and 73.33%, respectively. Although a common MAb in 2 new C-ELISA systems was used, variation in their percent inhibition, due to the use of different antigens, was observed. Taking into consideration the difference in percent inhibition of the 2 described assays and the commercial kit (50%), it was found that the RPV C-ELISA and the peptide C-ELISA are more specific and sensitive tools than the commercial kit for assessing herd immune status and for epidemiologic surveillance.
Variability of the QuantiFERON®-TB gold in-tube test using automated and manual methods.
Whitworth, William C; Goodwin, Donald J; Racster, Laura; West, Kevin B; Chuke, Stella O; Daniels, Laura J; Campbell, Brandon H; Bohanon, Jamaria; Jaffar, Atheer T; Drane, Wanzer; Sjoberg, Paul A; Mazurek, Gerald H
2014-01-01
The QuantiFERON®-TB Gold In-Tube test (QFT-GIT) detects Mycobacterium tuberculosis (Mtb) infection by measuring release of interferon gamma (IFN-γ) when T-cells (in heparinized whole blood) are stimulated with specific Mtb antigens. The amount of IFN-γ is determined by enzyme-linked immunosorbent assay (ELISA). Automation of the ELISA method may reduce variability. To assess the impact of ELISA automation, we compared QFT-GIT results and variability when ELISAs were performed manually and with automation. Blood was collected into two sets of QFT-GIT tubes and processed at the same time. For each set, IFN-γ was measured in automated and manual ELISAs. Variability in interpretations and IFN-γ measurements was assessed between automated (A1 vs. A2) and manual (M1 vs. M2) ELISAs. Variability in IFN-γ measurements was also assessed on separate groups stratified by the mean of the four ELISAs. Subjects (N = 146) had two automated and two manual ELISAs completed. Overall, interpretations were discordant for 16 (11%) subjects. Excluding one subject with indeterminate results, 7 (4.8%) subjects had discordant automated interpretations and 10 (6.9%) subjects had discordant manual interpretations (p = 0.17). Quantitative variability was not uniform; within-subject variability was greater with higher IFN-γ measurements and with manual ELISAs. For subjects with mean TB Responses ±0.25 IU/mL of the 0.35 IU/mL cutoff, the within-subject standard deviation for two manual tests was 0.27 (CI95 = 0.22-0.37) IU/mL vs. 0.09 (CI95 = 0.07-0.12) IU/mL for two automated tests. QFT-GIT ELISA automation may reduce variability near the test cutoff. Methodological differences should be considered when interpreting and using IFN-γ release assays (IGRAs).
Serodiagnosis of toxocariasis by ELISA using crude antigen of Toxocara canis larvae.
Jin, Yan; Shen, Chenghua; Huh, Sun; Sohn, Woon-Mok; Choi, Min-Ho; Hong, Sung-Tae
2013-08-01
Toxocariasis is a worldwide zoonosis caused by larvae of ascarid nematodes of dogs or cats, Toxocara canis or T. cati. Diagnosis of human toxocariasis currently relies on serology that uses T. canis excretory-secretory antigen to detect specific IgG antibodies by ELISA. We investigated the serodiagnostic efficacy of ELISA using crude antigen of T. canis larvae (TCLA). Serum specimens of 64 clinically confirmed toxocariasis, 115 healthy controls, and 119 other tissue-invading helminthiases were screened by ELISA using TCLA. The ELISA using TCLA showed 92.2% (59/64 patient samples) sensitivity and 86.6% (103/119) specificity. Its positive diagnostic predictivity was 78.7% and negative predictivity was 97.8%. No serum of healthy controls reacted but that of anisakiasis (45.5%), gnathostomiasis (19.2%), clonorchiasis (15.8%), sparganosis (11.1%), and cysticercosis (6.3%) cross-reacted. Immunoblot analysis on TCLA recognized antigenic proteins of 28- and 30-kDa bands in their dominant protein quantity and strong blotting reactivity. The present results indicate that the ELISA using our TCLA antigen is acceptable by the sensitivity and specificity for serodiagnosis of human toxocariasis. ELISA with TCLA is recommended to make differential diagnosis for patients with any sign of organ infiltration and eosinophilia.
Shirotani, Keiro; Futakawa, Satoshi; Nara, Kiyomitsu; Hoshi, Kyoka; Saito, Toshie; Tohyama, Yuriko; Kitazume, Shinobu; Yuasa, Tatsuhiko; Miyajima, Masakazu; Arai, Hajime; Kuno, Atsushi; Narimatsu, Hisashi; Hashimoto, Yasuhiro
2011-01-01
We have established high-throughput lectin-antibody ELISAs to measure different glycans on transferrin (Tf) in cerebrospinal fluid (CSF) using lectins and an anti-transferrin antibody (TfAb). Lectin blot and precipitation analysis of CSF revealed that PVL (Psathyrella velutina lectin) bound an unique N-acetylglucosamine-terminated N-glycans on “CSF-type” Tf whereas SSA (Sambucus sieboldiana agglutinin) bound α2,6-N-acetylneuraminic acid-terminated N-glycans on “serum-type” Tf. PVL-TfAb ELISA of 0.5 μL CSF samples detected “CSF-type” Tf but not “serum-type” Tf whereas SSA-TfAb ELISA detected “serum-type” Tf but not “CSF-type” Tf, demonstrating the specificity of the lectin-TfAb ELISAs. In idiopathic normal pressure hydrocephalus (iNPH), a senile dementia associated with ventriculomegaly, amounts of the SSA-reactive Tf were significantly higher than in non-iNPH patients, indicating that Tf glycan analysis by the high-throughput lectin-TfAb ELISAs could become practical diagnostic tools for iNPH. The lectin-antibody ELISAs of CSF proteins might be useful for diagnosis of the other neurological diseases. PMID:21876827
Shirotani, Keiro; Futakawa, Satoshi; Nara, Kiyomitsu; Hoshi, Kyoka; Saito, Toshie; Tohyama, Yuriko; Kitazume, Shinobu; Yuasa, Tatsuhiko; Miyajima, Masakazu; Arai, Hajime; Kuno, Atsushi; Narimatsu, Hisashi; Hashimoto, Yasuhiro
2011-01-01
We have established high-throughput lectin-antibody ELISAs to measure different glycans on transferrin (Tf) in cerebrospinal fluid (CSF) using lectins and an anti-transferrin antibody (TfAb). Lectin blot and precipitation analysis of CSF revealed that PVL (Psathyrella velutina lectin) bound an unique N-acetylglucosamine-terminated N-glycans on "CSF-type" Tf whereas SSA (Sambucus sieboldiana agglutinin) bound α2,6-N-acetylneuraminic acid-terminated N-glycans on "serum-type" Tf. PVL-TfAb ELISA of 0.5 μL CSF samples detected "CSF-type" Tf but not "serum-type" Tf whereas SSA-TfAb ELISA detected "serum-type" Tf but not "CSF-type" Tf, demonstrating the specificity of the lectin-TfAb ELISAs. In idiopathic normal pressure hydrocephalus (iNPH), a senile dementia associated with ventriculomegaly, amounts of the SSA-reactive Tf were significantly higher than in non-iNPH patients, indicating that Tf glycan analysis by the high-throughput lectin-TfAb ELISAs could become practical diagnostic tools for iNPH. The lectin-antibody ELISAs of CSF proteins might be useful for diagnosis of the other neurological diseases.
Quantitation of sperm bindable IgA and IgG in seminal fluid.
Howe, S E; Lynch, D M
1986-05-01
Seminal fluid and serum from 95 infertile males were assayed for sperm bindable immunoglobulins using an indirect ELISA with whole target sperm. The ELISA method was compared to seminal fluid and serum immobilization and agglutination assays (functional assays). In this infertile group, the ELISA assay was positive in 22% of seminal fluids (greater than 1.2 fg IgA/sperm and greater than 0.3 fg IgG/sperm). The seminal fluid antibodies were IgA and had an accompanying elevated IgG component in 78% of patients. There was a 96% correlation between negative seminal fluid functional assays and negative ELISA, and a 95% correlation between positive seminal fluid functional assays and positive ELISA. Positive serum sperm antibody tests were found in 71% of the infertile males with positive seminal fluid sperm antibodies, but 29% of the infertile males with strongly positive IgA seminal fluid sperm antibodies showed normal levels of serum sperm antibodies by either ELISA or functional assays. The ELISA method gives reproducible quantitation of sperm antibodies in seminal fluid and correlates well with accepted functional assays. Comparisons with serum sperm antibody assays suggests that seminal fluid sperm antibody analysis complements the serum analysis of sperm antibodies.
Sankar, Surya; Harshan, Hiron M; Somarajan, S R; Srivastava, S K
2010-06-01
A recombinant leptospiral lipoprotein, LigB, was evaluated for use in the diagnosis of bovine leptospirosis by enzyme-linked immunosorbent assay (rLigB IgG ELISA). The standard reference test (Microscopic agglutination test, MAT) of 200 serum samples from cattle suspected of leptospirosis showed that 95 (47.5%) samples had positive agglutination titres, which ranged from 100 to 1600. In rLigB IgG ELISA, 49% of the samples were positive. Sensitivity of IgG ELISA for 95 bovine sera, which had MAT titres of greater than or equal to 100, were 100%. ELISA showed a specificity of 97.1% with 105 bovine sera, which were negative at a 1:50 dilution in MAT for Leptospira interrogans serovars. The results of ELISA and MAT correspond very good. When analytical specificity of IgG ELISA was evaluated using bovine serum samples from animals showing the serum antibodies to other pathogens, no cross-reaction was observed. Thus the recombinant LigB IgG ELISA can be used instead of the MAT as an aid to the diagnosis of bovine leptospirosis. Copyright 2009. Published by Elsevier India Pvt Ltd.
Clavijo, A; Lin, M; Riva, J; Mallory, M; Lin, F; Zhou, E M
2001-02-01
The sequence encoding a truncated E2 glycoprotein of the Alfort/187 strain of classical swine fever virus (CSFV) was expressed in Escherichia coli using the pET expression system and the recombinant product purified by Ni-NTA agarose affinity chromatography. The antigenicity of this recombinant protein was demonstrated by immunoblot using anti- CSFV-specific antibodies. A monoclonal antibody was produced against the truncated E2 protein and used as competitor in an ELISA for the detection of antibodies to CSFV. Specific antibodies were demonstrated by competitive ELISA (C-ELISA) as early as 21 days post-infection (dpi) in experimentally infected pigs. Seroconversion was demonstrated by C-ELISA and neutralising peroxidase-linked assay (NPLA) in all infected animals by 4 weeks. No cross-reaction with antibodies to bovine viral diarrhoea virus (BVDV) was seen in the C-ELISA using sera from experimentally infected pigs. The C-ELISA is not intended as a substitute for the NPLA. However, it is expected it will be useful for monitoring and prevalence studies. It will also assist in testing a large number of samples in the event of an outbreak. Copyright 2001 Harcourt Publishers Ltd.
Development of a Peptide ELISA for the Diagnosis of Aleutian Mink Disease
Wang, Yang; Lu, Rongguang; Hu, Bo; Lv, Shuang; Xue, Xianghong; Li, Xintong; Ling, Mingyu; Fan, Sining; Zhang, Hailing; Yan, Xijun
2016-01-01
Aleutian disease (AD) is a common immunosuppressive disease in mink farms world-wide. Since the 1980s, counterimmunoelectrophoresis (CIEP) has been the main detection method for infection with the Aleutian Mink Disease Virus (AMDV). In this study, six peptides derived from the AMDV structural protein VP2 were designed, synthesized, and used as ELISA antigens to detect anti-AMDV antibodies in the sera of infected minks. Serum samples were collected from 764 minks in farms from five different provinces, and analyzed by both CIEP (a gold standard) and peptide ELISA. A peptide designated P1 (415 aa–433 aa) exhibited good antigenicity. A novel ELISA was developed using ovalbumin-linked peptide P1 to detect anti-AMDV antibodies in mink sera. The sensitivity and specificity of the peptide ELISA was 98.0% and 97.5%, respectively. Moreover, the ELISA also detected 342 early-stage infected samples (negative by CIEP and positive by PCR), of which 43.6% (149/342) were true positives. These results showed that the peptide ELISA had better sensitivity compared with CIEP, and therefore could be preferable over CIEP for detecting anti-AMDV antibodies in serological screening. PMID:27802320
Kondo, Mika; Tsuzuki, Kazuyuki; Hamada, Hiroshi; Yamaguchi Murakami, Yukie; Uchigashima, Mikiko; Saka, Machiko; Watanabe, Eiki; Iwasa, Seiji; Narita, Hiroshi; Miyake, Shiro
2012-02-01
A direct competitive enzyme-linked immunosorbent assay (dc-ELISA) was developed for residue analysis of azoxystrobin in garden crops, for which the maximum residue limits (MRLs) are 0.5-50 mg/kg in Japan. For hapten synthesis, an ethyl carboxyl group was introduced to the 4-position of the 2-cyanophenoxy group in azoxystrobin, and its cyano group was changed to a methyl group. An anti-azoxystrobin monoclonal antibody was prepared from mice immunized with hapten-keyhole limpet hemocyanin conjugate. The dc-ELISA using prepared antibody showed 50-250-fold higher sensitivity compared to the MRLs. The working range of the dc-ELISA was 10-200 ng/mL. The dc-ELISA showed high specificity to azoxystrobin. When methanol extracts from nine kinds of garden crops spiked with azoxystrobin ranging near the MRLs were analyzed, the determined results by the dc-ELISA agreed well with the results of their controls. In addition, azoxystrobin spiked in garden crops homogenates was satisfactorily extracted by methanol solution and easily analyzed. The recovery rate of dc-ELISA was 96-109% and correlated well with the results obtained by HPLC analysis.
Multi-Laboratory Validation of Estrone (E1) ELISA Methods
This project is a round-robin evaluation of commercially available Enzyme-Linked Immunosorbent Assay (ELISA) technology to quantitatively or qualitatively measure the hormone estrone (E1) in combined animal feeding operation (CAFO) receiving streams. ELISA is meant to be a simpl...
Raj, G Dhinakar; Ratnapraba, S; Matheswaran, K; Nachimuthu, K
2004-01-01
A single-serum dilution ELISA for egg drop syndrome (EDS) virus-specific antibodies was developed. In testing 425 chicken sera it was found to have a 93.6% sensitivity and 98.7% specificity relative to a hemagglutination inhibition (HI) test. The correlation coefficient for ELISA and HI titers was 0.793. The ELISA was efficacious in quantification of both vaccinal and infection antibodies and could routinely be used for screening large numbers of field sera.
Kanabagatte Basavarajappa, Mallikarjuna; Song, Haichen; Lamichhane, Chinta
2015-01-01
For detection of infectious laryngotracheitis virus (ILTV) antibody, glycoprotein B-, C-, and D-based enzyme-linked immunosorbent assays (B-, C-, and D-ELISAs, respectively) were developed. The B- and D-ELISAs showed enhanced detection of anti-ILTV antibodies in infected chickens compared to that of the commercial ELISA. Furthermore, the D-ELISA was efficient in detecting seroconversion with vectored vaccine, using recombinant Newcastle disease virus (rNDV) expressing glycoprotein D (gD) as the vaccine vector. PMID:25694519
Anitharaj, Velmurugan; Stephen, Selvaraj; Pradeep, Jothimani; Pooja, Pratheesh; Preethi, Sridharan
2017-01-01
Background: In the recent past, scrub typhus (ST) has been reported from different parts of India, based on Weil-Felix/enzyme-linked immunosorbent assay (ELISA)/indirect immunofluorescence assay (IFA). Molecular tests are applied only by a few researchers. Aims: Evaluation of a new commercial real time polymerase chain reaction (PCR) kit for molecular diagnosis of ST by comparing it with the commonly used IgM ELISA is our aim. Settings and Design: ST has been reported all over India including Puducherry and surrounding Tamil Nadu and identified as endemic for ST. This study was designed to correlate antibody detection by IgM ELISA and Orientia tsutsugamushi DNA in real time PCR. Materials and Methods: ST IgM ELISA (InBios Inc., USA) was carried out for 170 consecutive patients who presented with the symptoms of acute ST during 11 months (November, 2015– September, 2016). All 77 of these patients with IgM ELISA positivity and 49 of 93 IgM ELISA negative patients were subjected to real time PCR (Geno-Sen's ST real time PCR, Himachal Pradesh, India). Statistical Analysis: Statistical analysis for clinical and laboratory results was performed using IBM SPSS Statistics 17 for Windows (SPSS Inc., Chicago, USA). Chi-square test with Yates correction (Fisher's test) was employed for a small number of samples. Results and Conclusion: Among 77 suspected cases of acute ST with IgM ELISA positivity and 49 IgM negative patients, 42 and 7 were positive, respectively, for O. tsutsugamushi 56-kDa type-specific gene in real time PCR kit. Until ST IFA, the gold standard diagnostic test, is properly validated in India, diagnosis of acute ST will depend on both ELISA and quantitative PCR. PMID:28878522
Anitharaj, Velmurugan; Stephen, Selvaraj; Pradeep, Jothimani; Pooja, Pratheesh; Preethi, Sridharan
2017-01-01
In the recent past, scrub typhus (ST) has been reported from different parts of India, based on Weil-Felix/enzyme-linked immunosorbent assay (ELISA)/indirect immunofluorescence assay (IFA). Molecular tests are applied only by a few researchers. Evaluation of a new commercial real time polymerase chain reaction (PCR) kit for molecular diagnosis of ST by comparing it with the commonly used IgM ELISA is our aim. ST has been reported all over India including Puducherry and surrounding Tamil Nadu and identified as endemic for ST. This study was designed to correlate antibody detection by IgM ELISA and Orientia tsutsugamushi DNA in real time PCR. ST IgM ELISA (InBios Inc., USA) was carried out for 170 consecutive patients who presented with the symptoms of acute ST during 11 months (November, 2015- September, 2016). All 77 of these patients with IgM ELISA positivity and 49 of 93 IgM ELISA negative patients were subjected to real time PCR (Geno-Sen's ST real time PCR, Himachal Pradesh, India). Statistical analysis for clinical and laboratory results was performed using IBM SPSS Statistics 17 for Windows (SPSS Inc., Chicago, USA). Chi-square test with Yates correction (Fisher's test) was employed for a small number of samples. Among 77 suspected cases of acute ST with IgM ELISA positivity and 49 IgM negative patients, 42 and 7 were positive, respectively, for O. tsutsugamushi 56-kDa type-specific gene in real time PCR kit. Until ST IFA, the gold standard diagnostic test, is properly validated in India, diagnosis of acute ST will depend on both ELISA and quantitative PCR.
Zheng, Tao; Parkes, John P
2011-12-15
Rabbit haemorrhagic disease (RHD) is an acute fatal disease of domestic and wild European rabbits (Oryctolagus cuniculus) caused by RHD virus (RHDV). Accurate assessment of immunity is of great importance for the conservation and control of wild rabbits. We evaluated a competitive ELISA (cELISA) against isotype ELISAs for assessing the protective immunity against the disease by challenging 50 wild-caught rabbits with a lethal dose of RHDV. Death or survival to the challenge was used as a criterion to determine the performance characteristics of the assay for the assessment of immunity in rabbits. At 1:10 dilution, a serum exhibiting ≥ 25% inhibition (1:10(25)) was regarded as the presence of RHDV-specific antibodies. Eleven of 16 (68.8%) rabbits with antibodies at 1:10(25) (<1:40) died of RHD. When the cut-off was moved from 25% to 50% inhibition (1:10(50)) at 1:10 serum dilution, the assay sensitivity, specificity and accuracy for the protective immunity were improved from 84%, 54.2% and 69.4% to 84%, 100% and 91.8%, respectively. We also demonstrated at the epitope amino acid sequence level why the presence of the RHDV-cross reactive benign rabbit calicivirus, which interfered with isotype ELISAs, had little impact on the specificity of the cELISA for the diagnosis of RHDV infection. The presence of RHDV-specific antibody at 1:10(50) by the cELISA is a reliable indicator for the protective immunity. In contrast to isotype ELISAs, the cELISA is a valuable specific tool for monitoring the herd immunity to RHD for the conservation and management of wild rabbits in the field. Copyright © 2011 Elsevier B.V. All rights reserved.
Validation of 2 commercial Neospora caninum antibody enzyme linked immunosorbent assays
Wu, John T.Y.; Dreger, Sally; Chow, Eva Y.W.; Bowlby, Evelyn E.
2002-01-01
Abstract This is a validation study of 2 commercially available enzyme linked immunosorbent assays (ELISA) for the detection of antibodies against Neospora caninum in bovine serum. The results of the reference sera (n = 30) and field sera from an infected beef herd (n = 150) were tested by both ELISAs and the results were compared statistically. When the immunoblotting results of the reference bovine sera were compared to the ELISA results, the same identity score (96.67%) and kappa values (K) (0.93) were obtained for both ELISAs. The sensitivity and specificity values for the IDEXX test were 100% and 93.33% respectively. For the Biovet test 93.33% and 100% were obtained. The corresponding positive (PV+) and negative predictive (PV−) values for the 2 assays were 93.75% and 100% (IDEXX), and 100% and 93.75% (Biovet). In the 2nd study, competitive inhibition ELISA (c-ELISA) results on bovine sera from an infected herd were compared to the 2 sets of ELISA results. The identity scores of the 2 ELISAs were 98% (IDEXX) and 97.33% (Biovet). The K values calculated were 0.96 (IDEXX) and 0.95 (Biovet). For the IDEXX test the sensitivity and specificity were 97.56% and 98.53%, whereas for the Biovet assay 95.12% and 100% were recorded, respectively. The corresponding PV+ and PV− values were 98.77% and 97.1% (IDEXX), and 100% and 94.44% (Biovet). Our validation results showed that the 2 ELISAs worked equally well and there was no statistically significant difference between the performance of the 2 tests. Both tests showed high reproducibility, repeatability and substantial agreement with results from 2 other laboratories. A quality assurance based on the requirement of the ISO/IEC 17025 standards has been adopted throughout this project for test validation procedures. PMID:12418782
Rodríguez-Cortés, Alhelí; Ojeda, Ana; Todolí, Felicitat; Alberola, Jordi
2013-01-31
Leishmania infantum (syn. Leishmania chagasi) is the etiological agent of a widespread serious zoonotic disease that affects both humans and dogs. Prevalence and incidence of the canine infection are important parameters to determine the risk and the ways to control this reemergent zoonosis. Unfortunately, there is not a gold standard test for Leishmania infection. Our aim was to assess the operative validity of commercial tests used to detect antibodies to Leishmania in serum samples from experimental infections. Three ELISA tests (LEISCAN(®) Leishmania ELISA Test, INGEZIM(®) LEISHMANIA, and INGEZIM(®) LEISHMANIA VET), three immunochromatographic tests (INGEZIM(®) LEISHMACROM, SNAP(®) Leishmania, and WITNESS(®) Leishmania), and one IFAT were evaluated. LEISCAN(®) Leishmania ELISA test achieved the highest sensitivity and accuracy (both 0.98). Specificity was 1 for all tests except for IFAT. All tests but IFAT obtained a positive predictive value of 1, while the maximum negative predictive value was achieved by LEISCAN(®) Leishmania ELISA Test (0.93). The best positive likelihood ratio was obtained by INGEZIM(®) LEISHMANIA VET (30.26), while the best negative likelihood ratio was obtained by LEISCAN(®) Leishmania ELISA Test (0.02). The highest diagnostic odds ratio was achieved by LEISCAN(®) Leishmania ELISA Test (729.00). The largest area under the ROC curve was obtained by LEISCAN(®) Leishmania ELISA Test (0.981). Quantitative ELISA based tests performmed better than qualitative tests ("Rapid Tests"), and the test best suited to detect Leishmania in infected dogs and to provide clinically useful information was LEISCAN(®) Leishmania ELISA Test. This and other results point also to the need of revising the status of IFAT as a gold standard for the diagnosis of leishmaniasis. Copyright © 2012 Elsevier B.V. All rights reserved.
Pannwitz, Gunter; Haas, Bernd; Hoffmann, Bernd; Fischer, Sebastian
2009-01-01
In a closed pig establishment housing about 18,000 pigs, 2895 gilts were tested pre-export for SVD (swine vesicular disease) antibodies using Ceditest/PrioCHECK SVDV-AB ELISA. 130 gilts (4.5%) tested positive. In addition, 561 animals of this farm were sampled per random for SVD serology. One in 241 weaners (0.4%), eight in 150 gilts (5.3%) and 18 in 170 (10.6%) pregnant sows tested ELISA SVD-antibody positive. Of the ELISA positive samples, 23 tested positive in VNT (virus neutralization test). Of these, 20 VNT-positive animals were re-sampled two weeks later and re-tested via ELISA and VNT in different laboratories, displaying falling titres with one to two animals remaining VNT-positive. Epidemiological investigations and clinical examinations on site did not yield any evidence for SVD. 745 faecal samples taken from individual pigs and collected from pens tested negative in SVDV-RNA-PCR. 40 of these samples tested negative in virus isolation on cell culture. Pathological examinations on fallen pigs did not reveal any evidence for SVD either. After comparing our ELISA results with data recorded in the ELISA validation by Chenard et al. (1998), we propose that the published test performance is perhaps not currently applicable for the commercial test. Provided that SVD-antibody negative pigs were tested, a specificity of 99.6% in weaners, 95.5% in gilts and 89.4% in pregnant sows would appear to be more appropriate for the Ceditest/PrioCHECK SVDV-AB ELISA. Details are provided for all examined pigs regarding husbandry, breed, age, weeks pregnant and previous vaccinations. The results of other serological tests on the same sera are given. Possible clusterings of false-positive SVD-ELISA results are discussed.
Anti-signal recognition particle autoantibody ELISA validation and clinical associations.
Aggarwal, Rohit; Oddis, Chester V; Goudeau, Danielle; Fertig, Noreen; Metes, Ilinca; Stephens, Chad; Qi, Zengbiao; Koontz, Diane; Levesque, Marc C
2015-07-01
The aim of this study was to develop and validate a quantitative anti-signal recognition particle (SRP) autoantibody serum ELISA in patients with myositis and longitudinal association with myositis disease activity. We developed a serum ELISA using recombinant purified full-length human SRP coated on ELISA plates and a secondary antibody that bound human IgG to detect anti-SRP binding. Protein immunoprecipitation was used as the gold standard for the presence of anti-SRP. Serum samples from three groups were analysed: SRP(+) myositis subjects by immunoprecipitation, SRP(-) myositis subjects by immunoprecipitation and non-myositis controls. The ELISA's sensitivity, specificity, positive predictive value and negative predictive value were evaluated. Percentage agreement and test-retest reliability were assessed. Serial samples from seven SRP immunoprecipitation-positive subjects were also tested, along with serum muscle enzymes and manual muscle testing. Using immunoprecipitation, we identified 26 SRP(+) myositis patients and 77 SRP(-) controls (including 38 patients with necrotizing myopathy). Non-myositis control patients included SLE (n = 4) and SSc (n = 7) patients. Anti-SRP positivity by ELISA showed strong agreement (97.1%) with immunoprecipitation (κ = 0.94). The sensitivity, specificity, positive predictive value, and negative predictive value of the anti-SRP ELISA were 88, 100, 100 and 96, respectively. The area under the curve was 0.94, and test-retest reliability was strong (r = 0.91, P < 0.001). Serial samples showed that anti-SRP levels paralleled changes in muscle enzymes and manual muscle testing. We developed a quantitative ELISA for detecting serum anti-SRP autoantibodies and validated the assay in myositis. Longitudinal assessment of SRP levels by ELISA may be a useful biomarker for disease activity. © The Author 2014. Published by Oxford University Press on behalf of the British Society for Rheumatology. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Development of in-house serological methods for diagnosis and surveillance of chikungunya.
Galo, Saira Saborío; González, Karla; Téllez, Yolanda; García, Nadezna; Pérez, Leonel; Gresh, Lionel; Harris, Eva; Balmaseda, Ángel
2017-08-21
To develop and evaluate serological methods for chikungunya diagnosis and research in Nicaragua. Two IgM ELISA capture systems (MAC-ELISA) for diagnosis of acute chikungunya virus (CHIKV) infections, and two Inhibition ELISA Methods (IEM) to measure total antibodies against CHIKV were developed using monoclonal antibodies (mAbs) and hyperimmune serum at the National Virology Laboratory of Nicaragua in 2014-2015. The sensitivity, specificity, predictive values, and agreement of the MAC-ELISAs were obtained by comparing the results of 198 samples (116 positive; 82 negative) with the Centers for Disease Control and Prevention's IgM ELISA (Atlanta, Georgia, United States; CDC-MAC-ELISA). For clinical evaluation of the four serological techniques, 260 paired acute and convalescent phase serum samples of suspected chikungunya cases were used. All four assays were standardized by determining the optimal concentrations of the different reagents. Processing times were substantially reduced compared to the CDC-MAC-ELISA. For the MAC-ELISA systems, a sensitivity of 96.6% and 97.4%, and a specificity of 98.8% and 91.5% were obtained using mAb and hyperimmune serum, respectively, compared with the CDC method. Clinical evaluation of the four serological techniques versus the CDC real-time RT-PCR assay resulted in a sensitivity of 95.7% and a specificity of 88.8%-95.9%. Two MAC-ELISA and two IEM systems were standardized, demonstrating very good quality for chikungunya diagnosis and research demands. This will achieve more efficient epidemiological surveillance in Nicaragua, the first country in Central America to produce its own reagents for serological diagnosis of CHIKV. The methods evaluated here can be applied in other countries and will contribute to sustainable diagnostic systems to combat the disease.
Development of in-house serological methods for diagnosis and surveillance of chikungunya
Galo, Saira Saborío; González, Karla; Téllez, Yolanda; García, Nadezna; Pérez, Leonel; Gresh, Lionel; Harris, Eva; Balmaseda, Ángel
2017-01-01
Objective To develop and evaluate serological methods for chikungunya diagnosis and research in Nicaragua. Methods Two IgM ELISA capture systems (MAC-ELISA) for diagnosis of acute chikungunya virus (CHIKV) infections, and two Inhibition ELISA Methods (IEM) to measure total antibodies against CHIKV were developed using monoclonal antibodies (mAbs) and hyperimmune serum at the National Virology Laboratory of Nicaragua in 2014–2015. The sensitivity, specificity, predictive values, and agreement of the MAC-ELISAs were obtained by comparing the results of 198 samples (116 positive; 82 negative) with the Centers for Disease Control and Prevention’s IgM ELISA (Atlanta, Georgia, United States; CDC-MAC-ELISA). For clinical evaluation of the four serological techniques, 260 paired acute and convalescent phase serum samples of suspected chikungunya cases were used. Results All four assays were standardized by determining the optimal concentrations of the different reagents. Processing times were substantially reduced compared to the CDC-MAC-ELISA. For the MAC-ELISA systems, a sensitivity of 96.6% and 97.4%, and a specificity of 98.8% and 91.5% were obtained using mAb and hyperimmune serum, respectively, compared with the CDC method. Clinical evaluation of the four serological techniques versus the CDC real-time RT-PCR assay resulted in a sensitivity of 95.7% and a specificity of 88.8%–95.9%. Conclusion Two MAC-ELISA and two IEM systems were standardized, demonstrating very good quality for chikungunya diagnosis and research demands. This will achieve more efficient epidemiological surveillance in Nicaragua, the first country in Central America to produce its own reagents for serological diagnosis of CHIKV. The methods evaluated here can be applied in other countries and will contribute to sustainable diagnostic systems to combat the disease. PMID:28902269
Development and evaluation of porcine cysticercosis QuickELISA in Triturus EIA analyzer.
Handali, Sukwan; Pattabhi, Sowmya; Lee, Yeuk-Mui; Silva-Ibanez, Maria; Kovalenko, Victor A; Levin, Andrew E; Gonzalez, Armando E; Roberts, Jacquelin M; Garcia, Hector H; Gilman, Robert H; Hancock, Kathy; Tsang, Victor C W
2010-01-01
We evaluated three diagnostic antigens (recombinant GP50, recombinant T24H, and synthetic Ts18var1) for cysticercosis and found that all three performed well in detecting cysticercosis in humans and pigs in several assay formats. These antigens were adapted to a new antibody detection format (QuickELISA). With one single incubation step which involves all reactants except the enzyme substrate, the QuickELISA is particularly suited for automation. We formatted the QuickELISA for the Triturus EIA analyzer for testing large numbers of samples. We found that in QuickELISA formats rGP50 and rT24H have better sensitivity and specificity than sTs18var1 for detecting porcine cysticercosis.
Code of Federal Regulations, 2011 CFR
2011-01-01
... microagglutination test, the enzyme-linked immunosorbent assay test (ELISA), or the rapid serum test for all poultry... react on rapid serum test or enzyme-labeled immunosorbent assay test (ELISA), or blood from birds that... inhibition (HI) test, the microhemagglutination inhibition test, the enzyme-linked immunosorbent assay (ELISA...
USDA-ARS?s Scientific Manuscript database
The antibody is central to the performance of an ELISA providing the basis of analyte selection and detection. It is the interaction of antibody with analyte under defined conditions that dictates the outcome of the ELISA and deviations in those conditions will impact assay performance. The aim of...
BANNAI, Hiroshi; NEMOTO, Manabu; TSUJIMURA, Koji; YAMANAKA, Takashi; MAEDA, Ken; KONDO, Takashi
2015-01-01
To increase the sensitivity of an enzyme-linked immunosorbent assay (ELISA) for equine herpesvirus type 4 (EHV-4) that uses a 12-mer peptide of glycoprotein G (gG4-12-mer: MKNNPIYSEGSL) [4], we used a longer peptide consisting of a 24-mer repeat sequence (gG4-24-mer: MKNNPIYSEGSLMLNVQHDDSIHT) as an antigen. Sera of horses experimentally infected with EHV-4 reacted much more strongly to the gG4-24-mer peptide than to the gG4-12-mer peptide. We used peptide ELISAs to test paired sera from horses naturally infected with EHV-4 (n=40). gG4-24-mer ELISA detected 37 positive samples (92.5%), whereas gG4-12-mer ELISA detected only 28 (70.0%). gG4-24-mer ELISA was much more sensitive than gG4-12-mer ELISA. PMID:26424485
Bannai, Hiroshi; Nemoto, Manabu; Tsujimura, Koji; Yamanaka, Takashi; Maeda, Ken; Kondo, Takashi
2016-02-01
To increase the sensitivity of an enzyme-linked immunosorbent assay (ELISA) for equine herpesvirus type 4 (EHV-4) that uses a 12-mer peptide of glycoprotein G (gG4-12-mer: MKNNPIYSEGSL) [4], we used a longer peptide consisting of a 24-mer repeat sequence (gG4-24-mer: MKNNPIYSEGSLMLNVQHDDSIHT) as an antigen. Sera of horses experimentally infected with EHV-4 reacted much more strongly to the gG4-24-mer peptide than to the gG4-12-mer peptide. We used peptide ELISAs to test paired sera from horses naturally infected with EHV-4 (n=40). gG4-24-mer ELISA detected 37 positive samples (92.5%), whereas gG4-12-mer ELISA detected only 28 (70.0%). gG4-24-mer ELISA was much more sensitive than gG4-12-mer ELISA.
Estimates of Mumps Seroprevalence May Be Influenced by Antibody Specificity and Serologic Method
McGrew, Marcia; Williams, Nobia J.; Sowers, Sun B.; Bellini, William J.; Hickman, Carole J.
2014-01-01
Neutralizing antibodies are assumed to be essential for protection against mumps virus infection, but their measurement is labor- and time-intensive. For this reason, enzyme-linked immunosorbent assays (ELISAs) are typically used to measure mumps-specific IgG levels. However, since there is poor correlation between mumps neutralization titers and ELISAs that measure the presence of mumps-specific IgG levels, ELISAs that better correlate with neutralization are needed. To address this issue, we measured mumps antibody levels by plaque reduction neutralization, by a commercial ELISA (whole-virus antigen), and by ELISAs specific for the mumps nucleoprotein and hemagglutinin. The results indicate that differences in the antibody response to the individual mumps proteins could partially explain the lack of correlation among various serologic tests. Furthermore, the data indicate that some seropositive individuals have low levels of neutralizing antibody. If neutralizing antibody is important for protection, this suggests that previous estimates of immunity based on whole-virus ELISAs may be overstated. PMID:24371258
A comparison of two antigen-detection ELISA for detecting infection of Dirofilaria immitis in dogs.
Euclid, J M; Copeman, D B
1997-09-01
A survey on 87 dogs necropsied in the Townsville region revealed 34 (39%) were infected with Dirofilaria immitis. Infected dogs had an average of 6.1 adult worms in the heart and associated blood vessels. The VetRED assay detected 23 of the 34 infected dogs (sensitivity 65%) and the Og4C3 ELISA detected 27 (sensitivity 80%). Sensitivity of the VetRED and Og4C3 ELISA increased to 88 and 94% respectively in dogs with three or more worms. Both tests detected correctly all uninfected dogs. Despite the higher accuracy of the Og4C3 ELISA, compared to the VetRED assay, it is unlikely to be used widely as a field test for heartworm unless it can be modified from its present plate ELISA format which takes 4 hours, into one which is more rapid and convenient. However, as a reference ELISA, it may well be worthwhile in situations which require considerable accuracy for detecting D. immitis infection.
Iacono-Connors, L C; Novak, J; Rossi, C; Mangiafico, J; Ksiazek, T
1994-01-01
We developed an antigen capture enzyme-linked immunosorbent assay (ELISA) which does not require purified protective antigen (PA) for detection of human antibodies to Bacillus anthracis PA. Lysates of Spodoptera frugiperda (Sf-9) cells infected with recombinant baculovirus containing the PA gene were used as the source of PA to develop the ELISA. Recombinant PA from crude Sf-9 cell lysates or PA purified from B. anthracis Sterne strain was captured by an anti-PA monoclonal antibody coated onto microtiter plates. We demonstrated that human serum antibody titers to PA were identical in the ELISA whether we used crude Sf-9 cell lysates containing recombinant baculovirus-expressed PA or purified Sterne PA. Finally, false-positive results observed in a direct ELISA were eliminated with this antigen capture ELISA. Thus, the antigen capture ELISA with crude preparations of baculovirus-expressed PA is reliable, safe, and inexpensive for determining anti-PA antibody levels in human sera. PMID:7496927
Zhou, Jie; Liao, Yu-xue; Chen, Zhong; Li, Yu-chun; Gao, Lu-Lu; Chen, Yi-xiong; Cai, Lian-gong; Chen, Qing; Yu, Shou-yi
2008-05-01
To develop an simple and sensitive method for detecting anti-coronavirus IgG antibodies in bat sera based on enzyme-linked immunosorbent assay (ELISA). A commercial ELISA kit for detecting SARS-CoV antibody was modified for detecting coronavirus antibodies in bat serum samples. The second antibody in the kit was replaced with horseradish peroxidase-conjugated protein-A (HRP-SPA) based on the characteristics of binding between Staphylococcus aureus protein A (SPA) and mammal IgG Fc fragment. The sera of 55 fulvous fruit bats (Rousettus dasymallus) were tested using the SPA-ELISA. The test results of the positive and negative controls in the kit and the serum samples from convalescent ;patient were consistent with expectation. Coronavirus antibody was detected in 2 out of the 55 bat serum samples. Serum neutralization test confirmed the validity of the SPA-ELISA method. This SPA-ELISA method is applicable for detecting coronavirus antibody in bat sera.
Seroprevalence of Toxoplasma gondii in wild kangaroos using an ELISA
Parameswaran, N.; O'Handley, RM.; Grigg, ME.; Fenwick, SG.; Thompson, RCA.
2009-01-01
Infection with Toxoplasma gondii is a significant problem in Australian marsupials, and can lead to devastating disease and predispose animals to predation. T. gondii infection in kangaroos is also of public health significance due to the kangaroo meat trade. A moderate seroprevalence of T. gondii was observed in a study of western grey kangaroos located in the Perth metropolitan area in Western Australia. Of 219 kangaroos tested, 15.5% (95%CI: 10.7-20.3) were positive for T. gondii antibodies using an ELISA developed to detect T. gondii IgG in macropod marsupials. When compared with the commercially available MAT (modified agglutination test), the ELISA developed was in absolute agreement and yielded a κ coefficient of 1.00. Of 18 kangaroos tested for the presence of T. gondii DNA by PCR, the 9 ELISA positive kangaroos tested PCR positive and the 9 ELISA negative kangaroos tested PCR negative indicating the ELISA protocol was both highly specific and sensitive and correlated 100% with the more labour intensive PCR assay. PMID:19567231
Enzyme-linked immunosorbent assay detection and bioactivity of Cry1Ab protein fragments.
Albright, Vurtice C; Hellmich, Richard L; Coats, Joel R
2016-12-01
The continuing use of transgenic crops has led to an increased interest in the fate of insecticidal crystalline (Cry) proteins in the environment. Enzyme-linked immunosorbent assays (ELISAs) have emerged as the preferred detection method for Cry proteins in environmental matrices. Concerns exist that ELISAs are capable of detecting fragments of Cry proteins, which may lead to an overestimation of the concentration of these proteins in the environment. Five model systems were used to generate fragments of the Cry1Ab protein, which were then analyzed by ELISAs and bioassays. Fragments from 4 of the model systems were not detectable by ELISA and did not retain bioactivity. Fragments from the proteinase K model system were detectable by ELISA and retained bioactivity. In most cases, ELISAs appear to provide an accurate estimation of the amount of Cry proteins in the environment, as detectable fragments retained bioactivity and nondetectable fragments did not retain bioactivity. Environ Toxicol Chem 2016;35:3101-3112. © 2016 SETAC. © 2016 SETAC.
Ivens, Katherine O; Baumert, Joseph L; Taylor, Steve L
2016-07-01
Numerous commercial enzyme-linked immunosorbent assay (ELISA) kits exist to quantitatively detect bovine milk residues in foods. Milk contains many proteins that can serve as ELISA targets including caseins (α-, β-, or κ-casein) and whey proteins (α-lactalbumin or β-lactoglobulin). Nine commercially-available milk ELISA kits were selected to compare the specificity and sensitivity with 5 purified milk proteins and 3 milk-derived ingredients. All of the milk kits were capable of quantifying nonfat dry milk (NFDM), but did not necessarily detect all individual protein fractions. While milk-derived ingredients were detected by the kits, their quantitation may be inaccurate due to the use of different calibrators, reference materials, and antibodies in kit development. The establishment of a standard reference material for the calibration of milk ELISA kits is increasingly important. The appropriate selection and understanding of milk ELISA kits for food analysis is critical to accurate quantification of milk residues and informed risk management decisions. © 2016 Institute of Food Technologists®
Khatami, Alireza; Seyedin, Zahra; Daneshpazhooh, Maryam
2015-01-01
Background. Serum desmoglein enzyme-linked immunosorbent assay (ELISA) is used for the diagnosis and monitoring of pemphigus diseases. Objectives. To compare the diagnostic accuracy of salivary antidesmoglein (Dsg) 1 and 3 ELISA in the diagnosis of pemphigus vulgaris (PV) patients with that of serum desmogleins ELISA. Methods. Eighty-six untreated PV patients and 180 age- and sex-matched PV-free controls were recruited in this case-control study. PV was diagnosed based on clinical, histopathological, and direct immunofluorescence findings. After processing, serum and salivary anti-Dsg 1 and 3 were measured by the ELISA method using Euroimmun kit (Lübeck, Germany). Results. Using the cut-off point of 20 relative units (RU)/mL, the serum anti-Dsg 1 and 3 ELISA were positive in 62 (72.1%) and 83 (96.5%) patients, respectively, and the salivary anti-Dsg 1 and 3 ELISA were positive in 31 (36.1%) and 63 (73.3%) patients, respectively. The specificity of salivary anti-Dsg 1 and anti-Dsg 3 were both 98.9%. Optimal cut-off values of 7.7 and 13.4 RU/mL were determined for the salivary anti-Dsg 1 and anti-Dsg 3 ELISA, respectively. Conclusion. Salivary anti-Dsg 1 and 3 ELISA with high specificities (98.9%) could be suggested as safe and noninvasive methods for the diagnosis of PV when obtaining a blood sample is difficult. PMID:25688364
Thiha, Aung; Ibrahim, Fatimah
2015-01-01
The enzyme-linked Immunosorbent Assay (ELISA) is the gold standard clinical diagnostic tool for the detection and quantification of protein biomarkers. However, conventional ELISA tests have drawbacks in their requirement of time, expensive equipment and expertise for operation. Hence, for the purpose of rapid, high throughput screening and point-of-care diagnosis, researchers are miniaturizing sandwich ELISA procedures on Lab-on-a-Chip and Lab-on-Compact Disc (LOCD) platforms. This paper presents a novel integrated device to detect and interpret the ELISA test results on a LOCD platform. The system applies absorption spectrophotometry to measure the absorbance (optical density) of the sample using a monochromatic light source and optical sensor. The device performs automated analysis of the results and presents absorbance values and diagnostic test results via a graphical display or via Bluetooth to a smartphone platform which also acts as controller of the device. The efficacy of the device was evaluated by performing dengue antibody IgG ELISA on 64 hospitalized patients suspected of dengue. The results demonstrate high accuracy of the device, with 95% sensitivity and 100% specificity in detection when compared with gold standard commercial ELISA microplate readers. This sensor platform represents a significant step towards establishing ELISA as a rapid, inexpensive and automatic testing method for the purpose of point-of-care-testing (POCT) in resource-limited settings. PMID:25993517
ELISA-LOC: lab-on-a-chip for enzyme-linked immunodetection.
Sun, Steven; Yang, Minghui; Kostov, Yordan; Rasooly, Avraham
2010-08-21
A miniature 96 sample ELISA-lab-on-a-chip (ELISA-LOC) was designed, fabricated, and tested for immunological detection of Staphylococcal Enterotoxin B (SEB). The chip integrates a simple microfluidics system into a miniature ninety-six sample plate, allowing the user to carry out an immunological assay without a laboratory. Assay reagents are delivered into the assay plate without the need for separate devices commonly used in immunoassays. The ELISA-LOC was constructed using Laminated Object Manufacturing (LOM) technology to assemble six layers with an acrylic (poly(methyl methacrylate) (PMMA)) core and five polycarbonate layers micromachined by a CO(2) laser. The ELISA-LOC has three main functional elements: reagent loading fluidics, assay and detection wells, and reagent removal fluidics, a simple "surface tension" valve used to control the flow. To enhance assay sensitivity and to perform the assay without a lab, ELISA-LOC detection combines several biosensing elements: (1) carbon nanotube (CNT) technology to enhance primary antibody immobilization, (2) sensitive ECL (electrochemiluminescence) detection, and (3) a charge-coupled device (CCD) detector for measuring the light signal generated by ECL. Using a sandwich ELISA assay, the system detected SEB at concentrations as low as 0.1 ng ml(-1), which is similar to the reported sensitivity of conventional ELISA. The fluidics system can be operated by a syringe and does not require power for operation. This simple point-of-care (POC) system is useful for carrying out various immunological assays and other complex medical assays without a laboratory.
Enzyme-linked immunosorbent assay for ultratrace determination of antibiotics in aqueous samples.
Kumar, Kuldip; Thompson, Anita; Singh, Ashok K; Chander, Yogesh; Gupta, Satish C
2004-01-01
Two commercially available enzyme-linked immunosorbent assay (ELISA) kits that are commonly used for tylosin or tetracycline residues in meat and milk were adapted for ultratrace analysis of these antibiotics in surface and ground waters. These two antibiotics are commonly fed to swine, turkeys, and cattle at subtherapeutic doses for growth promotion purposes. Both ELISA techniques were found to be highly sensitive and selective for the respective antibiotics with detection limits of 0.10 and 0.05 microg L(-1) for tylosin and tetracycline, respectively. The recovery of both tylosin and tetracycline from spiked samples of lake waters, runoff samples, soil saturation extracts, and nanopure water was close to 100%. Tetracycline ELISA was highly specific for tetracycline and chlortetracycline but not for other forms of tetracycline (oxytetracycline, demeclocycline, and doxycycline). Analysis of a few liquid swine manure samples by liquid chromatography-mass spectrometry (LC-MS) showed lower concentrations for chlortetracycline as compared with concentrations obtained using ELISA. However, the concentrations of tylosin from ELISA were comparable with that of LC-MS. The lower concentrations of chlortetracycline obtained by LC-MS in manure samples indicate the presence of other similar or transformed compounds that were detected by ELISA but not determined by LC-MS. These results indicate that both ELISA kits can be useful tools for low-cost screening of tylosin, tetracycline, and chlortetracycline in environmental waters. Furthermore, both ELISA procedures are rapid, portable, and easily adaptable for testing of multiple samples simultaneously.
77 FR 11137 - Government-Owned Inventions; Availability for Licensing
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-24
... nonspecific, and the diagnosis is frequently difficult and delayed. The inventors established a rapid ELISA assay to evaluate biomarker levels in serum. The ELISA assay tests a novel combination of two biomarkers...-invasive ELISA serum assay. Potential for high sensitivity. Cost effective. Development Stage: Pilot. Early...
7 CFR 301.92-12 - Testing protocols.
Code of Federal Regulations, 2012 CFR
2012-01-01
.... The following methodology is approved by APHIS. (a) Optional ELISA Prescreening. An APHIS-approved ELISA may be used to prescreen plant samples to determine the presence of Phytophthora spp. (1) Negative... ELISA prescreening, no further testing is required. The nursery may be considered free of evidence of...
Undergraduate Laboratory Module for Implementing ELISA on the High Performance Microfluidic Platform
ERIC Educational Resources Information Center
Giri, Basant; Peesara, Ravichander R.; Yanagisawa, Naoki; Dutta, Debashis
2015-01-01
Implementing enzyme-linked immunosorbent assays (ELISA) in microchannels offers several advantages over its traditional microtiter plate-based format, including a reduced sample volume requirement, shorter incubation period, and greater sensitivity. Moreover, microfluidic ELISA platforms are inexpensive to fabricate and allow integration of…
A Simple ELISA Exercise for Undergraduate Biology.
ERIC Educational Resources Information Center
Baker, William P.; Moore, Cathy R.
Understanding of immunological techniques such as the Enzyme Linked Immuno Sorbent Assay (ELISA) is an important part of instructional units in human health, developmental biology, microbiology, and biotechnology. This paper describes a simple ELISA exercise for undergraduate biology that effectively simulates the technique using a paper model.…
7 CFR 301.92-12 - Testing protocols.
Code of Federal Regulations, 2013 CFR
2013-01-01
.... The following methodology is approved by APHIS. (a) Optional ELISA Prescreening. An APHIS-approved ELISA may be used to prescreen plant samples to determine the presence of Phytophthora spp. (1) Negative... ELISA prescreening, no further testing is required. The nursery may be considered free of evidence of...
7 CFR 301.92-12 - Testing protocols.
Code of Federal Regulations, 2010 CFR
2010-01-01
.... The following methodology is approved by APHIS. (a) Optional ELISA Prescreening. An APHIS-approved ELISA may be used to prescreen plant samples to determine the presence of Phytophthora spp. (1) Negative... ELISA prescreening, no further testing is required. The nursery may be considered free of evidence of...
7 CFR 301.92-12 - Testing protocols.
Code of Federal Regulations, 2011 CFR
2011-01-01
.... The following methodology is approved by APHIS. (a) Optional ELISA Prescreening. An APHIS-approved ELISA may be used to prescreen plant samples to determine the presence of Phytophthora spp. (1) Negative... ELISA prescreening, no further testing is required. The nursery may be considered free of evidence of...
7 CFR 301.92-12 - Testing protocols.
Code of Federal Regulations, 2014 CFR
2014-01-01
.... The following methodology is approved by APHIS. (a) Optional ELISA Prescreening. An APHIS-approved ELISA may be used to prescreen plant samples to determine the presence of Phytophthora spp. (1) Negative... ELISA prescreening, no further testing is required. The nursery may be considered free of evidence of...
Abstract describes the development of an enzyme-linked immunosorbent assay (ELISA) method for monitoring 2,4-dichlorophenoxyacetic acid (2,4-D exposures). The ELISA is compared with a gas chromatograhy/mass spectrometry procedure. ELISA method development steps and comparative ...
Beaver, A; Cazer, C L; Ruegg, P L; Gröhn, Y T; Schukken, Y H
2016-02-01
Mycobacterium avium ssp. paratuberculosis (MAP), the etiologic agent of Johne's disease in dairy cattle, may enter the bulk tank via environmental contamination or direct excretion into milk. Traditionally, diagnostics to identify MAP in milk target either MAP antibodies (by ELISA) or the organism itself (by culture or PCR). High ELISA titers may be directly associated with excretion of MAP into milk but only indirectly linked to environmental contamination of the bulk tank. Patterns of bulk-milk ELISA and bulk-milk PCR results could therefore provide insight into the routes of contamination and level of infection or environmental burden. Coupled with questionnaire responses pertaining to management, the results of these diagnostic tests could reveal correlations with herd characteristics or on-farm practices that distinguish herds with high and low environmental bulk-tank MAP contamination. A questionnaire on hygiene, management, and Johne's specific parameters was administered to 292 dairy farms in New York, Oregon, and Wisconsin. Bulk-tank samples were collected from each farm for evaluation by real-time PCR and ELISA. Before DNA extraction and testing of the unknown samples, bulk-milk template preparation was optimized with respect to parameters such as MAP fractionation patterns and lysis. Two regression models were developed to explore the relationships among bulk-tank PCR, ELISA, environmental predictors, and herd characteristics. First, ELISA optical density (OD) was designated as the outcome in a linear regression model. Second, the log odds of being PCR positive in the bulk tank were modeled using binary logistic regression with penalized maximum likelihood. The proportion of PCR-positive bulk tanks was highest for New York and for organic farms, providing a clue as to the geographical patterns of MAP-positive bulk-tank samples and relationship to production type. Bulk-milk PCR positivity was also higher for large relative to small herds. The models revealed that bulk-milk PCR result could predict ELISA OD, with PCR-positive results corresponding to high bulk-milk ELISA titers. Similarly, ELISA was a predictor of PCR result, although the association was stronger for organic farms. Despite agreement between high bulk-milk ELISA titers and positive PCR results, a large proportion of high ELISA farms had PCR-negative bulk tanks, suggesting that farms are able to maintain satisfactory hygiene and management despite a presence of MAP in these herds. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
2016-08-01
platforms. 15. SUBJECT TERMS Antibody Antibody Technology Program (ATP) Quality Enzyme-linked immunosorbent assay ( ELISA ) Biosurveillance Single-chain...2.6 Thermal Stress Test............................................................................................4 2.7 ELISA ...3.5 ELISA Results .................................................................................................11 3.6 SPR Results
42 CFR 71.53 - Requirements for importers of nonhuman primates.
Code of Federal Regulations, 2014 CFR
2014-10-01
... Trade in Endangered Species. ELISA means enzyme-linked immunosorbent assay, a type of laboratory test... serum for immunoglobulin G (IgG) antibodies to filovirus by using an ELISA methodology, or other method... for filovirus antigen by using the antigen-capture ELISA method must be submitted to a qualified...
Assessment of an ELISA Laboratory Exercise
ERIC Educational Resources Information Center
Robinson, David L.; Lau, Joann M.
2012-01-01
The enzyme-linked immunosorbent assay (ELISA) is a powerful immunological technique for quantifying small amounts of compounds and has been used in research and clinical settings for years. Although there are laboratory exercises developed to introduce the ELISA technique to students, their ability to promote student learning has not been…
Code of Federal Regulations, 2014 CFR
2014-01-01
... immunosorbent assay test (ELISA), or the rapid serum test for all poultry; and the stained antigen, rapid whole... test or enzyme-labeled immunosorbent assay test (ELISA), or blood from birds that react on the stained... enzyme-linked immunosorbent assay (ELISA) test,3 a polymerase chain reaction (PCR)-based test, or a...
42 CFR 71.53 - Requirements for importers of nonhuman primates.
Code of Federal Regulations, 2013 CFR
2013-10-01
... Trade in Endangered Species. ELISA means enzyme-linked immunosorbent assay, a type of laboratory test... serum for immunoglobulin G (IgG) antibodies to filovirus by using an ELISA methodology, or other method... for filovirus antigen by using the antigen-capture ELISA method must be submitted to a qualified...
76 FR 4920 - Government-Owned Inventions; Availability for Licensing
Federal Register 2010, 2011, 2012, 2013, 2014
2011-01-27
... appear to be distinct from each other. Available for licensing is a Plk1 ELISA assay using peptide... binding property, an easy and reliable ELISA assay has been developed to quantify Plk1 expression levels... sequence. ELISA assay to quantify Plk1 expression and kinase activity. Advantages: Rapid, highly sensitive...
76 FR 15791 - National Poultry Improvement Plan and Auxiliary Provisions
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-22
... microhemagglutination inhibition test, the enzyme-linked immunosorbent assay (ELISA) test,\\3\\ a polymerase chain [[Page... samplings and/or culture of reactors. \\3\\ Procedures for the enzyme-linked immunosorbent assay (ELISA) test... Immunosorbent Assay (ELISA),'' Proceedings, 30th Western Poultry Disease Conference, pp. 63-66, March 1981...
Code of Federal Regulations, 2012 CFR
2012-01-01
... immunosorbent assay test (ELISA), or the rapid serum test for all poultry; and the stained antigen, rapid whole... test or enzyme-labeled immunosorbent assay test (ELISA), or blood from birds that react on the stained... enzyme-linked immunosorbent assay (ELISA) test,3 a polymerase chain reaction (PCR)-based test, or a...
Code of Federal Regulations, 2013 CFR
2013-01-01
... immunosorbent assay test (ELISA), or the rapid serum test for all poultry; and the stained antigen, rapid whole... test or enzyme-labeled immunosorbent assay test (ELISA), or blood from birds that react on the stained... enzyme-linked immunosorbent assay (ELISA) test,3 a polymerase chain reaction (PCR)-based test, or a...
An inhibition enzyme-linked immunosorbent assay (ELISA) was used to determine polychlorinated biphenyls (PCBs) in house dust and soil. Soil and house dust samples were analyzed for PCB by both gas chromatography/electron capture detection (GC/ECD) and ELISA methods. A correlati...
Abstract describes a streamlined ELISA method developed to quantitatively measure 2,4-D in human urine samples. Method development steps and comparison with gas chromatography/mass spectrometry are presented. Results indicated that the ELISA method could be used as a high throu...
Kai, Junhai; Puntambekar, Aniruddha; Santiago, Nelson; Lee, Se Hwan; Sehy, David W; Moore, Victor; Han, Jungyoup; Ahn, Chong H
2012-11-07
In this work we introduce a novel microfluidic enzyme linked immunoassays (ELISA) microplate as the next generation assay platform for unparalleled assay performances. A combination of microfluidic technology with standard SBS-configured 96-well microplate architecture, in the form of microfluidic microplate technology, allows for the improvement of ELISA workflows, conservation of samples and reagents, improved reaction kinetics, and the ability to improve the sensitivity of the assay by multiple analyte loading. This paper presents the design and characterization of the microfluidic microplate, and its application in ELISA.
Parreiras, P M; Sirota, L A; Wagner, L D; Menzies, S L; Arciniega, J L
2009-07-16
Complexities of lethal challenge models have prompted the investigation of immunogenicity assays as potency tests of anthrax vaccines. An ELISA and a lethal toxin neutralization assay (TNA) were used to measure antibody response to Protective Antigen (PA) in mice immunized once with either a commercial or a recombinant PA (rPA) vaccine formulated in-house. Even though ELISA and TNA results showed correlation, ELISA results may not be able to accurately predict TNA results in this single immunization model.
Generation and Characterization of Protective Antibodies to Marburg Virus
2017-04-03
of cells following viral replication of the complex. The macaque developed increasing anti-GP Ab titers as evaluated by ELISA with a titer of 1:12800...those of the author and are not necessarily endorsed by the U.S. Army. SUPPLEMENTAL DATA: Table S-1. ELISA serum titer response following each...x 400 µL at 0.9x109 VRP/mL ELISA Titer (GP) NT >1/316,000 1/500,000 NT ELISA Titer (Live Virus) NT >1/316,000 1/450,000 NT Table S-2
Kanabagatte Basavarajappa, Mallikarjuna; Song, Haichen; Lamichhane, Chinta; Samal, Siba K
2015-05-01
For detection of infectious laryngotracheitis virus (ILTV) antibody, glycoprotein B-, C-, and D-based enzyme-linked immunosorbent assays (B-, C-, and D-ELISAs, respectively) were developed. The B- and D-ELISAs showed enhanced detection of anti-ILTV antibodies in infected chickens compared to that of the commercial ELISA. Furthermore, the D-ELISA was efficient in detecting seroconversion with vectored vaccine, using recombinant Newcastle disease virus (rNDV) expressing glycoprotein D (gD) as the vaccine vector. Copyright © 2015, American Society for Microbiology. All Rights Reserved.
Seroprevalence of Toxoplasma gondii in southern districts of Tamil Nadu using IgG-ELISA.
Sucilathangam, G; Palaniappan, N; Sreekumar, C; Anna, T
2012-10-01
The present study was conducted to assess the seroprevalence of Toxoplasma gondii in and around Tirunelveli by in-house IgG assay using ELISA. Serum samples from 175 immunodeficient and 175 immunocompetent patients were collected at Tirunelveli district, Tamil Nadu from May 2006 to October 2007. They were subjected into in-house IgG assay using enzyme-linked immune sorbent assay (ELISA) in which tachyzoite soluble antigen derived from solubilised whole organisms was used. Out of 350 patients tested by IgG ELISA, 46 patients (13.14%) had antibodies for toxoplasmosis with mean OD value of 0.2 ± 0.073 and the OD value ranged from 0.144 to 0.444. Among the immunocompetent group of 175 patients, 19 patients (10.86%) had antibodies to toxoplasmosis whereas, in immunodeficient group of 175 patients, 27 patients (15.43%) had antibodies for toxoplasmosis. There was no statistical difference (P > 0.05) between the immunocompetent and immunodeficient group. The sensitivity and specificity of IgG ELISA in detecting toxoplasmosis was 90 and 100%, respectively. The overall seroprevalence of toxoplasmosis in and around Tirunelveli district of Tamil Nadu was 13.14% based on IgG ELISA. The study has proved ELISA to be a sensitive and specific procedure for the serodiagnosis of toxoplasmosis.
Serodiagnosis of Toxocariasis by ELISA Using Crude Antigen of Toxocara canis Larvae
Jin, Yan; Shen, Chenghua; Huh, Sun; Sohn, Woon-Mok; Choi, Min-Ho
2013-01-01
Toxocariasis is a worldwide zoonosis caused by larvae of ascarid nematodes of dogs or cats, Toxocara canis or T. cati. Diagnosis of human toxocariasis currently relies on serology that uses T. canis excretory-secretory antigen to detect specific IgG antibodies by ELISA. We investigated the serodiagnostic efficacy of ELISA using crude antigen of T. canis larvae (TCLA). Serum specimens of 64 clinically confirmed toxocariasis, 115 healthy controls, and 119 other tissue-invading helminthiases were screened by ELISA using TCLA. The ELISA using TCLA showed 92.2% (59/64 patient samples) sensitivity and 86.6% (103/119) specificity. Its positive diagnostic predictivity was 78.7% and negative predictivity was 97.8%. No serum of healthy controls reacted but that of anisakiasis (45.5%), gnathostomiasis (19.2%), clonorchiasis (15.8%), sparganosis (11.1%), and cysticercosis (6.3%) cross-reacted. Immunoblot analysis on TCLA recognized antigenic proteins of 28- and 30-kDa bands in their dominant protein quantity and strong blotting reactivity. The present results indicate that the ELISA using our TCLA antigen is acceptable by the sensitivity and specificity for serodiagnosis of human toxocariasis. ELISA with TCLA is recommended to make differential diagnosis for patients with any sign of organ infiltration and eosinophilia. PMID:24039286
Benkirane, S; Nicolas, A; Galteau, M M; Siest, G
1991-06-01
Two immuno-assay methods (RIA and ELISA) have been developed for the accurate and sensitive measurement of cotinine in human body fluids (serum, saliva). RIA uses [3H]cotinine as antigen and charcoal/dextran for separating cotinine-bound antibodies from the free derivative. Another technique (ELISA) was developed to avoid the use of radio-labelled compounds and to determine cotinine in large populations, including passive or non-smokers who usually present very low concentrations. The two techniques were analytically validated. The detection limit was similar (0.1 micrograms/l) and the precision was better than 10% for both techniques. Non-smoker values ranged from 0.1 to 17 micrograms/l by ELISA and 0.1 to 27.5 micrograms/l by RIA, whereas smoker values ranged from 50 to 1000 micrograms/l (ELISA) and from 70 to 800 micrograms/l (RIA). The comparative analysis of cotinine in 96 human sera revealed a good correlation between the two methods (r = 0.97) and a reliable discrimination between the populations of non-smokers and smokers. As usual, the ELISA is more rapid (4 h 30 min) than the RIA (longer than 48 h). ELISA is proposed for use in the epidemiological investigation of the human tobacco risk.
Khan, Mohsin; Dhanwani, Rekha; Kumar, Jyoti S; Rao, P V Lakshmana; Parida, Manmohan
2014-07-01
Despite the fact that Chikungunya resurgence is associated with epidemic of unprecedented magnitude, there are challenges in the field of its clinical diagnosis. However, serological tests in an ELISA format provide a rapid tool for the diagnosis of Chikungunya infection. Indeed, ELISAs based on recombinant proteins hold a great promise as these methods are cost effective and are free from the risk of handling biohazardous material. In this study, the performance of recombinant CHIKV antigens was compared in various ELISA formats for the diagnosis of Chikungunya. Two recombinant antigens derived from the envelope proteins of Chikungunya virus were prepared and evaluated by comparing their competence for detecting circulating antibodies in serum samples of patients infected with CHIKV using MAC-ELISA and indirect IgM-ELISA. The efficacy of the recombinant antigens was also compared with the native antigen. The indirect antibody capture IgM microplate ELISA revealed ≥90% concordance with the native antigen in detecting the CHIKV specific IgM antibodies whereas the recombinant antigen based MAC-ELISA showed 100% specificity. The recombinant antigens used in this study were effective and reliable targets for the diagnosis of CHIKV infection and also provide an alternative for native antigen use which is potentially biohazardous. © 2013 Wiley Periodicals, Inc.
G-protein based ELISA as a potency test for rabies vaccines.
Chabaud-Riou, Martine; Moreno, Nadège; Guinchard, Fabien; Nicolai, Marie Claire; Niogret-Siohan, Elisabeth; Sève, Nicolas; Manin, Catherine; Guinet-Morlot, Françoise; Riou, Patrice
2017-03-01
The NIH test is currently used to assess the potency of rabies vaccine, a key criterion for vaccine release. This test is based on mice immunization followed by intracerebral viral challenge. As part of global efforts to reduce animal experimentation and in the framework of the development of Sanofi Pasteur next generation, highly-purified vaccine, produced without any material of human or animal origin, we developed an ELISA as an alternative to the NIH test. This ELISA is based on monoclonal antibodies recognizing specifically the native form of the viral G-protein, the major antigen that induces neutralizing antibody response to rabies virus. We show here that our ELISA is able to distinguish between potent and different types of sub-potent vaccine lots. Satisfactory agreement was observed between the ELISA and the NIH test in the determination of the vaccine titer and their capacity to discern conform from non-conform batches. Our ELISA meets the criteria for a stability-indicating assay and has been successfully used to develop the new generation of rabies vaccine candidates. After an EPAA international pre-collaborative study, this ELISA was selected as the assay of choice for the EDQM collaborative study aimed at replacing the rabies vaccine NIH in vivo potency test. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.
An enzyme-linked immunosorbent assay for detection of botulinum toxin-antibodies.
Dressler, Dirk; Gessler, Frank; Tacik, Pawel; Bigalke, Hans
2014-09-01
Antibodies against botulinum neurotoxin (BNT-AB) can be detected by the mouse protection assay (MPA), the hemidiaphragm assay (HDA), and by enzyme-linked immunosorbent assays (ELISA). Both MPA and HDA require sacrifice of experimental animals, and they are technically delicate and labor intensive. We introduce a specially developed ELISA for detection of BNT-A-AB and evaluate it against the HDA. Thirty serum samples were tested by HDA and by the new ELISA. Results were compared, and receiver operating characteristic analyses were used to optimize ELISA parameter constellation to obtain either maximal overall accuracy, maximal test sensitivity, or maximal test specificity. When the ELISA is optimized for sensitivity, a sensitivity of 100% and a specificity of 55% can be reached. When it is optimized for specificity, a specificity of 100% and a sensitivity of 90% can be obtained. We present an ELISA for BNT-AB detection that can be-for the first time-customized for special purposes. Adjusted for optimal sensitivity, it reaches the best sensitivity of all BNT-AB tests available. Using the new ELISA together with the HDA as a confirmation test allows testing for BNT-AB in large numbers of patients receiving BT drugs in an economical, fast, and more animal-friendly way. © 2014 International Parkinson and Movement Disorder Society.
Rhee, Jae-Sung; Kim, Bo-Mi; Jeong, Chang-Bum; Leung, Kenneth Mei Yee; Park, Gyung Soo; Lee, Jae-Seong
2013-11-01
To utilize the GST-S protein as a useful biomarker for environmental contamination, we developed a polyclonal antibody-based enzyme-linked immunosorbent assay (ELISA) in the intertidal copepod Tigriopus japonicus. Two polyclonal antibodies, TJ-GST-S1 and TJ-GST-S2, were raised against two TJ-GST-S synthetic peptides. Also a recombinant TJ-GST-S protein was purified as a standard for ELISA development. Each polyclonal antibody was tested by Western blot analysis and indirect ELISA. Of two polyclonal antibodies, TJ-GST-S2 ELISA was further employed due to its wide range of detection and the limit of specificity compared to those of TJ-GST-S1 ELISA system. After exposure to 4 metals (Ag, As, Cd, and Cu) to T. japonicus, the amount of TJ-GST-S protein was significantly elevated in a concentration-dependent manner. Also, TJ-GST-S protein was upregulated at relative high concentrations of B[α]P, PCB, and TBT. In this paper, we suggest that T. japonicas ELISA for TJ-GST-S2 is useful as a potential indicator system for marine contaminants. Copyright © 2013 Elsevier Ltd. All rights reserved.
Kwenti, Tebit Emmanuel; Njunda, Longdoh Anna; Tsamul, Beltine; Nsagha, Shey Dickson; Assob, Nguedia Jules-Clement; Tufon, Kukwah Anthony; Meriki, Dilonga Henry; Orock, Enow George
2017-08-01
In malaria endemic areas, infected blood donors serve as a source of infection to blood recipients, which may adversely affect their prognosis. This necessitates the proper screening of blood to be used for transfusion in these areas. The purpose of this study was to determine the prevalence of malaria parasitaemia in blood donors in Buea, Cameroon, and to evaluate the performance of a rapid diagnostic test (RDT), a malaria antibody enzyme-linked immunosorbent assay (ELISA), and a Plasmodium lactate dehydrogenase (pLDH) ELISA in the detection of asymptomatic malaria parasitaemia in the target population. In a prospective study conducted between September 2015 and June 2016, 1 240 potential blood donors were enrolled. The donors were screened for malaria parasites using Giemsa microscopy (GM) and a RDT. A sub-sample of 184 samples, comprising 88 positive and 96 negative samples, were selected for the evaluation of the pLDH ELISA and the antibody ELISA. The chi-square test and correlation analysis were performed as part of the statistical analyses. The statistical significance cut-off was set at P < 0.05. The prevalence of malaria parasitaemia in this study was found to be 8.1% (95% CI: 6.6 - 9.7). The prevalence was not observed to be dependent on the age or sex of the participants. The RDT had a sensitivity (88.0%), specificity (99.1%), and negative predictive value (99.0%) higher than the ELISAs. The performance of the pLDH ELISA, which demonstrated the highest positive predictive value (91.6%), was generally comparable to the RDT. The sensitivity was lowest with the antibody ELISA (69.9%), which also demonstrated the highest false positive and false negative rates. The detection threshold for the pLDH (three parasites/μl) was lower compared to the RDT (50 - 60 parasites/μl). Non-significant positive correlations were observed between the parasite density and the pLDH titers and malaria antibody titers. Overall, the RDT and the pLDH ELISA demonstrated a perfectly correlated agreement with GM, meanwhile the antibody ELISA demonstrated a substantially correlated agreement with GM. The pLDH is therefore recommended for mass screening of blood (to detect malaria parasitaemia) for transfusions in the study area. However, where this is not feasible, an RDT will suffice.
Sippel, J; Bukhtiari, N; Awan, M B; Krieg, R; Duncan, J F; Karamat, K A; Malik, I A; Igbal, L M; Legters, L
1989-06-01
Sera from 339 adult febrile patients in Pakistan were tested for antibodies to Salmonella typhi lipopolysaccharide by indirect immunoglobulin G (IgG) and IgM enzyme-linked immunosorbent assay (ELISA) and IgM capture ELISA. A total of 55 patients had S. typhi cultured from their blood, 20 had S. typhi cultured from their stool, 24 were blood or stool culture positive for S. paratyphi A, 41 were culture negative but clinically diagnosed as having enteric fever, 41 had gastrointestinal or urinary tract infections, 41 were clinically diagnosed as having malaria, 20 were smear-positive patients with malaria, 58 had respiratory infections, and the remaining 39 individuals were placed in a miscellaneous group who did not have Salmonella infection. The sensitivities of the indirect IgG ELISA, indirect IgM ELISA, and IgM capture ELISA determined with specimens obtained from the blood culture-positive patients with typhoid fever (positive controls) were 80, 64, and 62%, respectively. The specificities of the assays determined with sera from the patients with respiratory infections (negative controls) were 95, 95, and 97%, respectively. The percentage of smear-positive patients with malaria who were positive by these assays was lower than that in the negative control group. The percentages of individuals in the other patient categories who were positive by these tests were between those obtained with the positive and negative controls. Of the positive controls, 26 were positive by both IgM assays, 9 were IgM positive only by indirect ELISA, and 8 were IgM positive only by IgM capture ELISA. A total of 70% of the positive control patients who were tested for O agglutinins by the Widal tube agglutination assay were positive; however, 29% of the negative control patients were also positive. The indirect IgG ELISA was the single most effective test for the serodiagnosis of typhoid fever in this population.
Sippel, J; Bukhtiari, N; Awan, M B; Krieg, R; Duncan, J F; Karamat, K A; Malik, I A; Igbal, L M; Legters, L
1989-01-01
Sera from 339 adult febrile patients in Pakistan were tested for antibodies to Salmonella typhi lipopolysaccharide by indirect immunoglobulin G (IgG) and IgM enzyme-linked immunosorbent assay (ELISA) and IgM capture ELISA. A total of 55 patients had S. typhi cultured from their blood, 20 had S. typhi cultured from their stool, 24 were blood or stool culture positive for S. paratyphi A, 41 were culture negative but clinically diagnosed as having enteric fever, 41 had gastrointestinal or urinary tract infections, 41 were clinically diagnosed as having malaria, 20 were smear-positive patients with malaria, 58 had respiratory infections, and the remaining 39 individuals were placed in a miscellaneous group who did not have Salmonella infection. The sensitivities of the indirect IgG ELISA, indirect IgM ELISA, and IgM capture ELISA determined with specimens obtained from the blood culture-positive patients with typhoid fever (positive controls) were 80, 64, and 62%, respectively. The specificities of the assays determined with sera from the patients with respiratory infections (negative controls) were 95, 95, and 97%, respectively. The percentage of smear-positive patients with malaria who were positive by these assays was lower than that in the negative control group. The percentages of individuals in the other patient categories who were positive by these tests were between those obtained with the positive and negative controls. Of the positive controls, 26 were positive by both IgM assays, 9 were IgM positive only by indirect ELISA, and 8 were IgM positive only by IgM capture ELISA. A total of 70% of the positive control patients who were tested for O agglutinins by the Widal tube agglutination assay were positive; however, 29% of the negative control patients were also positive. The indirect IgG ELISA was the single most effective test for the serodiagnosis of typhoid fever in this population. PMID:2754002
Evaluation of Five Antibody Detection Tests for Diagnosis of Bovine Paratuberculosis
Collins, Michael T.; Wells, Scott J.; Petrini, Kristine R.; Collins, James E.; Schultz, Ronald D.; Whitlock, Robert H.
2005-01-01
Five diagnostic tests based on enzyme-linked immunosorbent assay (ELISA) technology for bovine paratuberculosis were evaluated by using individual serum or milk samples from 359 dairy cattle in seven paratuberculosis-free herds and 2,094 dairy cattle in seven Mycobacterium paratuberculosis-infected dairy herds. Three independent laboratories using three different culture procedures completed fecal cultures for M. paratuberculosis on these cattle and found 417 cows to be shedding M. paratuberculosis in their feces. An animal that was fecal culture positive for M. paratuberculosis by any of the three laboratories was considered a confirmed case of infection. The specificity of three ELISAs (two on serum and one on milk) was ≥99.8%. The specificity of the remaining two ELISAs, both done on serum, was 94.9 and 84.7%. Four of the five ELISAs evaluated produced similar sensitivity in detecting fecal culture-positive cattle (27.8 to 28.9%). Serum ELISA “D” had the lowest specificity (84.7%) and the highest sensitivity (44.5%), but if the cutoff value defining a positive test was changed from 125 to 250% (of the positive control) the sensitivity and specificity, 31.8 and 97.5%, respectively, were comparable to those of the other four assays. If the case definition for M. paratuberculosis infection was based on the culture results of a single laboratory instead of the combined results of three laboratories, ELISA sensitivity estimates were 45.7 to 50.0%. With the exception of ELISA D, assay agreement was high (kappa 0.66 to 0.85) for categorical assay interpretations (positive or negative), but linear regression of quantitative results showed low correlation coefficients (r2 = 0.40 to 0.68) due to the fact that ELISA results for some cows were high in one assay but low in another assay. Likelihood ratio analysis showed a direct relationship between the magnitude of ELISA result and the odds of a cow shedding M. paratuberculosis in its feces. If used judiciously and interpreted quantitatively, these ELISAs are useful tools in support of paratuberculosis control programs in dairy herds. PMID:15939741
Marcondes, Mary; de Lima, Valéria Marçal Félix; de Araújo, Maria de Fátima Lereno; Hiramoto, Roberto Mitsuyoshi; Tolezano, José Eduardo; Vieira, Rafael F C; Biondo, Alexander W
2013-11-08
Development of vaccines against canine visceral leishmaniasis (CVL) may provide a prophylactic barrier, but antibody response detected by standard diagnostic techniques may not separate vaccinated from naturally infected dogs. Moreover, anti-Leishmania antibody levels in vaccinated dogs may be detectable for months. Accordingly, the aim of the present study was to comparatively evaluate an "in-house" ELISA with three serological tests officially adopted by the Brazilian Ministry of Health for the diagnosis of CVL in dogs vaccinated with Leishmune(®). A total of 18 mongrel dogs were submitted to a complete protocol of the vaccine, monitored and evaluated in 5 times (T0-T4) up to 180 days after T0. Twenty-one days after the first dose (T1), 50% of the dogs were seropositive by the "in-house" ELISA and 5.5% by IFAT, while by the official ELISA and DPP(®) CVL rapid test all dogs tested negative. At time T2, 42 days after of the first dose, 100%, 83.3%, 11.1%, and 5.5% of the dogs were seropositive by the "in-house" ELISA, IFAT, official ELISA kit and the DPP(®) CVL rapid test, respectively. Ninety days after the first dose (T3), 100%, 83.3%, 72.2% and 33.3% of the dogs were seropositive by the "in-house" ELISA, official ELISA kit, IFAT, and the DPP(®) CVL rapid test, respectively. Finally, at time T4, 88.8%, 33.3%, 11.1% and 5.5% of the dogs were seropositive by the "in-house" ELISA, official ELISA kit, DPP(®) CVL rapid test and IFAT, respectively. In conclusion, dogs vaccinated with Leishmune(®) cross-react by an "in-house" ELISA and by the three official Brazilian serological tests for the diagnosis of canine visceral leishmaniasis up to six months after the first vaccine dose, and may be mistakenly diagnosed and removed. Copyright © 2013 Elsevier B.V. All rights reserved.
Adlhoch, Cornelia; Kaiser, Marco; Hoehne, Marina; Mas Marques, Andreas; Stefas, Ilias; Veas, Francisco; Ellerbrok, Heinz
2011-02-10
The principle of a capture ELISA is binding of specific capture antibodies (polyclonal or monoclonal) to the surface of a suitable 96 well plate. These immobilized antibodies are capable of specifically binding a virus present in a clinical sample. Subsequently, the captured virus is detected using a specific detection antibody. The drawback of this method is that a capture ELISA can only function for a single virus captured by the primary antibody. Human Apolipoprotein H (ApoH) or β2-glycoprotein 1 is able to poly-specifically bind viral pathogens. Replacing specific capture antibodies by ApoH should allow poly-specific capture of different viruses that subsequently could be revealed using specific detection antibodies. Thus, using a single capture ELISA format different viruses could be analysed depending on the detection antibody that is applied. In order to demonstrate that this is a valid approach we show detection of group A rotaviruses from stool samples as a proof of principle for a new method of capture ELISA that should also be applicable to other viruses. Stool samples of different circulating common human and potentially zoonotic group A rotavirus strains, which were pretested in commercial EIAs and genotyped by PCR, were tested in parallel in an ApoH-ELISA set-up and by quantitative real-time PCR (qPCR). Several control samples were included in the analysis. The ApoH-ELISA was suitable for the capture of rotavirus-particles and the detection down to 1,000 infectious units (TCID(50/ml)). Subsets of diagnostic samples of different G- and P-types were tested positive in the ApoH-ELISA in different dilutions. Compared to the qPCR results, the analysis showed high sensitivity, specificity and low cross-reactivity for the ApoH-ELISA, which was confirmed in receiver operating characteristics (ROC) analysis. In this study the development of a highly sensitive and specific capture ELISA was demonstrated by combining a poly-specific ApoH capture step with specific detection antibodies using group A rotaviruses as an example.
de Azevedo, Priscila Zacarias; Sylvestre, Tatiane Fernanda; Cavalcante, Ricardo de Souza; de Carvalho, Lídia Raquel; Moris, Daniela Vanessa; de Oliveira, Maria Luiza Cotrim Sartor; Mendes, Rinaldo Poncio
2015-01-01
The diagnosis of chronic pulmonary aspergillosis (CPA) depends on the radiologic image and the identification of specific antibodies. The present study aimed to evaluate accuracy parameters of enzyme-linked immunosorbent assay (ELISA) and of the determination of serum galactomannan level in the diagnosis of patients with CPA, comparing these results with the double agar gel immunodiffusion (DID) test. In addition, the prevalence of cross-reactivity and the serological progression after treatment were evaluated by comparing DID and ELISA. Six study groups were formed: G1: 22 patients with CPA, 17 of whom had Aspergillus fungus ball, one chronic cavitary pulmonary aspergillosis (CCPA) and four chronic fibrosing pulmonary aspergillosis (CFPA); G2: 28 patients with pulmonary tuberculosis (TB); G3: 23 patients with histoplasmosis (HST); G4: 50 patients with paracoccidioidomycosis (PCM); G5: 20 patients with cryptococcosis (CRC); and G6: 200 healthy controls. Serum antibodies were measured by DID and ELISA, with two antigen preparations—Aspergillus fumigatus (DID1, ELISA1) and a pool of A. fumigatus, A. flavus and A. niger antigens (DID2, ELISA2). The Platélia Aspergillus Enzyme Immunoassay (EIA) kit was used to measure galactomannan. The cut-off points of ELISA were determined for each antigen preparation and for the 95% and 99% confidence intervals. Despite the low sensitivity, DID was the technique of choice due to its specificity, positive and negative predictive values and positive likelihood ratio–especially with the antigen pool and due to the low frequency of cross-reactivity. ELISA1 and a 0.090 cut-off showed high sensitivity, specificity and negative predictive value, but a high frequency of cross-reactivity with CRC. The best degree of agreement was observed between ELISA1 and ELISA2. The detection of serum galactomannan showed high sensitivity, comparable to ELISA2. The immunodiffusion test showed an excellent relationship with the progression after treatment, which made it the reaction of choice for patient follow-up. PMID:26271000
Panneum, S; Rukkwamsuk, T
2017-03-01
For preventive and control strategies of Caprine Arthritis Encephalitis Virus (CAEV) infection in dairy goats, performance of the available diagnostic tests was described as one of the most important and necessary aspects. The study aimed at evaluating the diagnostic test performance, including PCR, ELISA and viral culture, for CAEV infection in dairy goats in Thailand. Blood samples of 29 dairy goats from five low- to medium-prevalence herds and one very low-prevalence herd were collected for PCR and ELISA methods. The performance of these two diagnostic methods was evaluated by comparing with cytopathic effects (CPE) in the co-cultivation of CAEV and primary synovial cells. Results indicated that sensitivity, specificity were, respectively, 69.6%, 100%, for PCR; and 95.7%, 83.3% for ELISA. The PCR assay tended to have lower sensitivity and higher specificity than ELISA. When multiple tests were applied, parallel testing provided sensitivity and specificity of 98.7% and 83.3%, while series testing showed sensitivity and specificity of 66.6% and 100% respectively. These results indicated that combination of ELISA and PCR provided some advantages and possibly offered optimal methods to detect CAEV-infected goats. Kappa value of the agreement between PCR and ELISA test was 0.34, indicating fair agreement. Regarding the possibility of antigenic variation between CAEV strains used in both PCR and ELISA assays, the actual circulating CAEV strain should be reviewed in order to develop and enhance the diagnostic tests using the CAE viral antigens derived from specific local strains of Thailand.
Van Emon, Jeanette M.; Chuang, Jane C.; Lordo, Robert A.; Schrock, Mary E.; Nichkova, Mikaela; Gee, Shirley J.; Hammock, Bruce D.
2010-01-01
A 96-microwell enzyme-linked immunosorbent assay (ELISA) method was evaluated to determine PCDDs/PCDFs in sediment and soil samples from an EPA Superfund site. Samples were prepared and analyzed by both the ELISA and a gas chromatography/high resolution mass spectrometry (GC/HRMS) method. Comparable method precision, accuracy, and detection level (8 ng kg−1) were achieved by the ELISA method with respect to GC/HRMS. However, the extraction and cleanup method developed for the ELISA requires refinement for the soil type that yielded a waxy residue after sample processing. Four types of statistical analyses (Pearson correlation coefficient, paired t-test, nonparametric tests, and McNemar’s test of association) were performed to determine whether the two methods produced statistically different results. The log-transformed ELISA-derived 2,3,7,8-tetrachlorodibenzo-p-dioxin values and logtransformed GC/HRMS-derived TEQ values were significantly correlated (r = 0.79) at the 0.05 level. The median difference in values between ELISA and GC/HRMS was not significant at the 0.05 level. Low false negative and false positive rates (<10%) were observed for the ELISA when compared to the GC/HRMS at 1000 ng TEQ kg−1. The findings suggest that immunochemical technology could be a complementary monitoring tool for determining concentrations at the 1000 ng TEQ kg−1 action level for contaminated sediment and soil. The ELISA could also be used in an analytical triage approach to screen and rank samples prior to instrumental analysis. PMID:18313102
He, Shengfa; Li, Xin; Gao, Jinyan; Tong, Ping; Chen, Hongbing
2018-01-01
Bovine β-lactoglobulin (BLG) is the major allergen in cows' milk, and the specific epitope plays a key role in food allergy. Developing a method specifically bind to the IgE epitope is necessary for testing BLG and its allergenic residues. The monoclonal antibody (1G9) specific to the IgE linear epitope for BLG was identified as high affinity and specificity. Based on 1G9, a sensitive fluorescent sandwich enzyme-linked immunosorbent assay (sELISA) was successfully developed using catalase-mediated fluorescence quenching of thiolated CdTe quantum dots in the presence of hydrogen peroxide as fluorescent signal output. The fluorescent sELISA showed high sensitivity and specificity, the limit of detection was 0.49 ng mL -1 , which was 16-fold lower than horseradish peroxidase (HRP)-based sELISA. The linear range for BLG detection were 125-4000 ng mL -1 (r = 0.9939) and 0.48-62.5 ng mL -1 (r = 0.9919). The recoveries and coefficients of variation were 94.25-109.83% and 4.38-20.29%, respectively. Allergenic residues were also detected in hydrolysed infant formulas. The results of fluorescent sELISA showed good performance as HRP-based sELISA and commercial sELISA kit. This proposed fluorescent sELISA could be employed to detect BLG and its allergenic residues in food with highly sensitivity, reliability, and recovery. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.
Schraer, S.M.; Shaw, D.R.; Boyette, M.; Coupe, R.H.; Thurman, E.M.
2000-01-01
Enzyme-linked immunosorbent assay (ELISA) data from surface water reconnaissance were compared to data from samples analyzed by gas chromatography for the pesticide residues cyanazine (2-[[4-chloro-6-(ethylamino)-l,3,5-triazin-2-yl]amino]-2-methylpropanenitrile ) and metolachlor (2-chloro-N-(2-ethyl-6-methylphenyl)-N-(2-methoxy-1-methylethyl)acetamide). When ELISA analyses were duplicated, cyanazine and metolachlor detection was found to have highly reproducible results; adjusted R2s were 0.97 and 0.94, respectively. When ELISA results for cyanazine were regressed against gas chromatography results, the models effectively predicted cyanazine concentrations from ELISA analyses (adjusted R2s ranging from 0.76 to 0.81). The intercepts and slopes for these models were not different from 0 and 1, respectively. This indicates that cyanazine analysis by ELISA is expected to give the same results as analysis by gas chromatography. However, regressing ELISA analyses for metolachlor against gas chromatography data provided more variable results (adjusted R2s ranged from 0.67 to 0.94). Regression models for metolachlor analyses had two of three intercepts that were not different from 0. Slopes for all metolachlor regression models were significantly different from 1. This indicates that as metolachlor concentrations increase, ELISA will over- or under-estimate metolachlor concentration, depending on the method of comparison. ELISA can be effectively used to detect cyanazine and metolachlor in surface water samples. However, when detections of metolachlor have significant consequences or implications it may be necessary to use other analytical methods.
Single-Tier Testing with the C6 Peptide ELISA Kit Compared with Two-Tier Testing for Lyme Disease
Wormser, Gary P.; Schriefer, Martin; Aguero-Rosenfeld, Maria E.; Levin, Andrew; Steere, Allen C.; Nadelman, Robert B.; Nowakowski, John; Marques, Adriana; Johnson, Barbara J. B.; Dumler, J. Stephen
2014-01-01
Background The two-tier serologic testing protocol for Lyme disease has a number of shortcomings including low sensitivity in early disease; increased cost, time and labor; and subjectivity in the interpretation of immunoblots. Methods The diagnostic accuracy of a single-tier commercial C6 ELISA kit was compared with two-tier testing. Results The C6 ELISA was significantly more sensitive than two-tier testing with sensitivities of 66.5% (95% C.I.:61.7-71.1) and 35.2% (95%C.I.:30.6-40.1), respectively (p<0.001) in 403 sera from patients with erythema migrans. The C6 ELISA had sensitivity statistically comparable to two-tier testing in sera from Lyme disease patients with early neurological manifestations (88.6% vs. 77.3%, p=0.13) or arthritis (98.3% vs. 95.6%, p= 0.38). Te specificities of C6 ELISA and two-tier testing in over 2200 blood donors, patients with other conditions, and Lyme disease vaccine recipients were found to be 98.9% and 99.5%, respectively (p<0.05, 95% C.I. surrounding the 0.6 percentage point difference of 0.04 to 1.15). Conclusions Using a reference standard of two-tier testing, the C6 ELISA as a single step serodiagnostic test provided increased sensitivity in early Lyme disease with comparable sensitivity in later manifestations of Lyme disease. The C6 ELISA had slightly decreased specificity. Future studies should evaluate the performance of the C6 ELISA compared with two-tier testing in routine clinical practice. PMID:23062467
AN ELISA ASSAY FOR HEME OXYGENASE (HO-1)
An ELISA assay for heme oxygenase (HO-l )
Abstract
A double antibody capture ELISA for the HO-l protein has been developed to separately quantitate HO-I protein. The use of 2.5% NP40 detergent greatly assists in freeing HO-l protein from membranes and/or other cel...
77 FR 7109 - Establishment of User Fees for Filovirus Testing of Nonhuman Primate Liver Samples
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-10
... assay (ELISA) or other appropriate methodology. Each specimen will be held for six months. After six... loss of the only commercially available antigen-detection ELISA filovirus testing facility. Currently... current methodology (ELISA) used to test NHP liver samples. This cost determines the amount of the user...
2016-02-01
Enzyme-linked immunosorbent assay ( ELISA ) Quality Testing MS2 coat protein (MS2CP) 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF... ELISA ................................................................................................................4 2.8 SPR Method...3.5 ELISA Results .................................................................................................11 3.6 SPR Results
75 FR 32184 - Government-Owned Inventions; Availability for Licensing
Federal Register 2010, 2011, 2012, 2013, 2014
2010-06-07
... ELISA for Detection of Serum Levels of Soluble IL-15 Receptor Alpha Description of Invention: The invention is an ELISA based assay that can be used in the clinical setting to detect the presence of soluble...-15R expression. Advantages: The assay is in the industry accepted ELISA format. This non-radioactive...
Host - HIF- 1alpha Pathway And Hypoxia: In Vitro Studies And Mathematical Model
2016-08-30
TERMS mathematical model, signaling pathways, hypoxia, immunohistochemistry, ELISA , inhalation chamber 16. SECURITY CLASSIFICATION OF: U 17...B. HIF-1α ELISA Procedure ........................................................................................27 Appendix C. HIF-1α Model...Quantifying Induction of HIF-1α Expression using ELISA .........................................15 Figure 10. Simulation Outputs from HIF-1α Kinetic
Development of an Indirect ELISA for Serological Diagnosis of Bovine herpesvirus 5
Campos, Fabrício S.; da Rosa, Matheus C.; Finger, Paula F.; de Oliveira, Patricia D.; Conceição, Fabricio R.; Fischer, Geferson; Roehe, Paulo M.; Leite, Fábio P. L.
2016-01-01
Bovine herpesviruses 1 and 5 (BoHV-1 and BoHV-5) are economically important pathogens, associated with a variety of clinical syndromes, including respiratory and genital disease, reproductive failure and meningoencephalitis. The standard serological assay to diagnose BoHV-1 and BoHV-5 infections is the virus neutralization test (VNT), a time consuming procedure that requires manipulation of infectious virus. In the present study a highly sensitive and specific single dilution indirect ELISA was developed using recombinant glycoprotein D from BoHV-5 as antigen (rgD5ELISA). Bovine serum samples (n = 450) were screened by VNT against BoHV-5a and by rgD5ELISA. Compared with the VNT, the rgD5ELISA demonstrated accuracy of 99.8%, with 100% sensitivity, 96.7% specificity and coefficient of agreement between the tests of 0.954. The rgD5ELISA described here shows excellent agreement with the VNT and is shown to be a simple, convenient, specific and highly sensitive virus-free assay for detection of serum antibodies to BoHV-5. PMID:26866923
Gómez-Ojeda, Armando; Jaramillo-Ortíz, Sarahi; Wrobel, Katarzyna; Wrobel, Kazimierz; Barbosa-Sabanero, Gloria; Luevano-Contreras, Claudia; de la Maza, Maria Pia; Uribarri, Jaime; Del Castillo, Ma Dolores; Garay-Sevilla, Ma Eugenia
2018-03-15
N ε -carboxymethyl-lysine (CML) is measured in food, but there is a controversy concerning the most convenient yet reliable method(s) for this task. This work compares three different ELISA assays and HPLC-ESI-ITMS/MS for the analysis of CML in several food items. The four methods showed the same decreasing order of CML concentration: beef, bacon>chicken > fish>dairy products>grain products>fruits/vegetables. HPLC-ESI-ITMS/MS results highly correlated with those obtained by ELISA performed with monoclonal CML-antibody (β=0.98, p<0.0001) whereas My Bio Source® kit results were not correlated with those provided by Lamider®. Small differences of CML concentrations in food items prepared by different culinary treatment were clearly distinguished by HPLC-ESI-ITMS/MS, but could not always be detected by ELISA. This work demonstrates a reasonable relationship between CM determined by ELISA and HPLC-ESI-ITMS/MS and therefore supports the implementation of ELISA in food CML/AGEs screening. Copyright © 2017. Published by Elsevier Ltd.
Guan, Yongguang; Wu, Xinlan; Meng, Hecheng
2013-08-01
In this study, a method for rapid detection of 5-hydroxymethyl-2-furfural (HMF) was investigated. Monoclonal antibody (anti-HMF) was prepared and evaluated by an indirect competitive ELISA (ic-ELISA) format. The optimized standard curve was y=-0.2097x+1.0432 [where x is the logarithm (base 10) of the values of the HMF concentration and y is the absorbance of ic-ELISA results tested at 490 nm] and the linear detection range was 0.008 to 32.768 mg/L. The percentage of cross-reactivity of HMF with 5 major furfural derivatives was less than 2.92%. Finally, the established ic-ELISA format was used to test HMF in milk, and compared with the result obtained by HPLC, which produced an error of about 0.3%. Based on the data in this experiment, we concluded that the established ic-ELISA format was reliable with a high specificity. Copyright © 2013 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Prevalence of Toxoplasma gondii infection in feral cats in Seoul, Korea.
Lee, Sang-Eun; Kim, Neung-Hee; Chae, Hee-Sun; Cho, Shin-Hyeong; Nam, Ho-Woo; Lee, Won-Ja; Kim, Sun-Heung; Lee, Jung-Hark
2011-02-01
The present study assessed the prevalence of Toxoplasma gondii infection in feral cat populations in Seoul using enzyme-linked immunosorbent assay (ELISA) and nested polymerase chain reaction (PCR). A total of 456 feral cats from 17 wards in Seoul was surveyed. The overall prevalence of T. gondii infection was 15.8% (69/456) by ELISA and 17.5% (80/456) by PCR; by gender, 17% (44/259) by ELISA and 16.2% (42/259) by PCR in males and 14.3% (28/196) by ELISA and 19.4% (38/196) by PCR in females. On a baseline of the Han River, prevalence was 15.1% (29/192) by ELISA and 15.6% (30/192) by PCR in the upper region and 16.4% (43/264) by ELISA and 18.9% (50/264) by PCR in the lower area. This suggested that toxoplasmosis is widespread throughout Seoul's feral cat population and it is critical that the city institute policies for the control of the feral cat population to reduce the risk of toxoplasmosis transmission to animals, including humans.
Dickey, Robert W; Plakas, Steven M; Jester, Edward L E; El Said, Kathleen R; Johannessen, Jan N; Flewelling, Leanne J; Scott, Paula; Hammond, Dan G; Van Dolah, Frances M; Leighfield, Tod A; Bottein Dachraoui, Marie-Yasmine; Ramsdell, John S; Pierce, Richard H; Henry, Mike S; Poli, Mark A; Walker, Calvin; Kurtz, Jan; Naar, Jerome; Baden, Daniel G; Musser, Steve M; White, Kevin D; Truman, Penelope; Miller, Aaron; Hawryluk, Timothy P; Wekell, Marleen M; Stirling, David; Quilliam, Michael A; Lee, Jung K
A thirteen-laboratory comparative study tested the performance of four methods as alternatives to mouse bioassay for the determination of brevetoxins in shellfish. The methods were N2a neuroblastoma cell assay, two variations of the sodium channel receptor binding assay, competitive ELISA, and LC/MS. Three to five laboratories independently performed each method using centrally prepared spiked and naturally incurred test samples. Competitive ELISA and receptor binding (96-well format) compared most favorably with mouse bioassay. Between-laboratory relative standard deviations (RSDR) ranged from 10 to 20% for ELISA and 14 to 31% for receptor binding. Within-laboratory (RSDr) ranged from 6 to 15% for ELISA, and 5 to 31% for receptor binding. Cell assay was extremely sensitive but data variation rendered it unsuitable for statistical treatment. LC/MS performed as well as ELISA on spiked test samples but was inordinately affected by lack of toxin-metabolite standards, uniform instrumental parameters, or both, on incurred test samples. The ELISA and receptor binding assay are good alternatives to mouse bioassay for the determination of brevetoxins in shellfish.
Kapur-Ghai, J; Kaur, M; Goel, P
2014-09-01
Root-knot nematodes (Meloidogyne incognita) are obligate, sedentary plant endoparasites that are extremely polyphagous in nature and cause severe economic losses in agriculture. Hence, it is essential to control the parasite at an early stage. For any control strategy to be effective, an early and accurate diagnosis is of paramount importance. Immunoassays have the inherent advantages of sensitivity and specificity; have the potential to identify and quantify these plant-parasitic nematodes. Hence, in the present studies, enzyme-linked immunosorbent assay (ELISA) has been developed for the detection of M.incognita antigens. First an indirect ELISA was developed for detection and titration of anti-M.incognita antibodies. Results indicated as high as 320 K titre of the antisera. Finally competitive inhibition ELISA was developed employing these anti-M.incognita antibodies for detection of M.incognita antigens. Sensitivity of ELISA was 10 fg. Competitive inhibition ELISA developed in the present studies has the potential of being used as an easy, rapid, specific and sensitive diagnostic tool for the detection of M.incognita infection.
Laborde, Juan M; Sguazza, Guillermo H; Fuentealba, Nadia A; Corva, Santiago G; Carbone, Cecilia; Galosi, Cecilia M
In this study we developed an indirect ELISA to detect antibodies against Minute Virus of Mice (MVM) using an antigen produced from BHK-21 cells infected with a prototype strain of the virus. The optimal antigen concentration and serum dilutions were established. In order to analyze variability in the laboratory, reproducibility and repeatability within and between plates were determined. Then, a panel of 460 sera from conventional facilities and previously classified as positive or negative by the indirect fluorescent antibody assay was analyzed. The cutoff value was determined by a receiver operating characteristic (ROC) curve. The results of the indirect ELISA were compared with those of the indirect fluorescent antibody assay. The ELISA assay showed 100% sensitivity and 99% specificity. ELISA is a useful tool to be developed in standard virology laboratories and can be used for screening animals faster than the traditional indirect fluorescent antibody assay. Copyright © 2017 Asociación Argentina de Microbiología. Publicado por Elsevier España, S.L.U. All rights reserved.
Development of a species-specific coproantigen ELISA for human Taenia solium taeniasis.
Guezala, Maria-Claudia; Rodriguez, Silvia; Zamora, Humberto; Garcia, Hector H; Gonzalez, Armando E; Tembo, Alice; Allan, James C; Craig, Philip S
2009-09-01
Taenia solium causes human neurocysticercosis and is endemic in underdeveloped countries where backyard pig keeping is common. Microscopic fecal diagnostic methods for human T. solium taeniasis are not very sensitive, and Taenia saginata and Taenia solium eggs are indistinguishable under the light microscope. Coproantigen (CoAg) ELISA methods are very sensitive, but currently only genus (Taenia) specific. This paper describes the development of a highly species-specific coproantigen ELISA test to detect T. solium intestinal taeniasis. Sensitivity was maintained using a capture antibody of rabbit IgG against T. solium adult whole worm somatic extract, whereas species specificity was achieved by utilization of an enzyme-conjugated rabbit IgG against T. solium adult excretory-secretory (ES) antigen. A known panel of positive and negative human fecal samples was tested with this hybrid sandwich ELISA. The ELISA test gave 100% specificity and 96.4% sensitivity for T. solium tapeworm carriers (N = 28), with a J index of 0.96. This simple ELISA incorporating anti-adult somatic and anti-adult ES antibodies provides the first potentially species-specific coproantigen test for human T. solium taeniasis.
Huang, Yi; Zhu, Youjie; Yang, Mengshi; Zhang, Zhenqing; Song, Donglin; Yuan, Zhiming
2014-12-01
Full-length nucleoproteins from Ebola and Marburg viruses were expressed as His-tagged recombinant proteins in Escherichia coli and nucleoprotein-based enzyme-linked immunosorbent assays (ELISAs) were established for the detection of antibodies specific to Ebola and Marburg viruses. The ELISAs were evaluated by testing antisera collected from rabbit immunized with Ebola and Marburg virus nucleoproteins. Although little cross-reactivity of antibodies was observed in anti-Ebola virus nucleoprotein rabbit antisera, the highest reactions to immunoglobulin G (IgG) were uniformly detected against the nucleoprotein antigens of homologous viruses. We further evaluated the ELISA's ability to detect antibodies to Ebola and Marburg viruses using human sera samples collected from individuals passing through the Guangdong port of entry. With a threshold set at the mean plus three standard deviations of average optical densities of sera tested, the ELISA systems using these two recombinant nucleoproteins have good sensitivity and specificity. These results demonstrate the usefulness of ELISA for diagnostics as well as ecological and serosurvey studies of Ebola and Marburg virus infection.
Intamaso, Uraiwan; Ketkhunthod, Sitthisak
2014-05-01
Hepatitis A virus (HAV) contamination in food can lead to major health problems. We developed a combination reverse transcription (RT) PCR method plus enzyme-linked immunosorbent assay (ELISA) to detect HAV in fresh oysters harvested along the east coast of the Gulf of Thailand. Viral nucleic acid was extracted via the glycine-arginine-polyethylene glycol method followed by RT-PCR amplification with specifically designed primers against HAV and an ELISA to detect the digoxigenin-labeled RT-PCR products. The ELISA in concert with the RT-PCR protocol further increased the detection sensitivity by 100-fold for the HAV genome and 10-fold in artificially contaminated oysters. The overall sensitivity of the RT-PCR in combination with the ELISA was 31.88 pg and 16 PFU/g, respectively. The ELISA increases the specificity of the RT-PCR assay for detecting naturally occurring HAV in oysters. This combined RT-PCR-ELISA approach is a practical and sensitive method for HAV detection and can be utilized in routine screening for HAV in shellfish.
Biffin, A H; Jones, M A; Palmer, S R
1993-07-01
The routine use of ELISA and complement fixation tests in the diagnosis of suspected clinical cases of hydatid disease was evaluated. In the ELISA test, dialysed and filtered sheep cyst fluid was used as antigen and two positive cut-off points--+3SD and +2SD of the mean absorbance values of the control sera--were evaluated. The predictive values of ELISA tests were 82% and 90% for positive tests, and 86% and 82% for negative tests, respectively with the two cut-off points. In a population survey of blood donors and veterinary workers in Powys, 4% and 8%, respectively, had ELISA values above the lower cut-off point. However, it would not be appropriate to use the same test for diagnostic population screening in Wales since the predictive value of the test is likely to be very low in this setting. Serological surveys with the ELISA may be of use in monitoring the progress of the South Powys Hydatid Control Programme. The use of cumulative percentages was found to be a useful method of comparing whole distributions of results in different populations.
Monaci, Linda; Brohée, Marcel; Tregoat, Virginie; van Hengel, Arjon
2011-07-15
Milk allergens are common allergens occurring in foods, therefore raising concern in allergic consumers. Enzyme-linked immunosorbent assay (ELISA) is, to date, the method of choice for the detection of food allergens by the food industry although, the performance of ELISA might be compromised when severe food processing techniques are applied to allergen-containing foods. In this paper we investigated the influence of baking time on the detection of milk allergens by using commercial ELISA kits. Baked cookies were chosen as a model food system and experiments were set up to study the impact of spiking a matrix food either before, or after the baking process. Results revealed clear analytical differences between both spiking methods, which stress the importance of choosing appropriate spiking methodologies for method validation purposes. Finally, since the narrow dynamic range of quantification of ELISA implies that dilution of samples is required, the impact of sample dilution on the quantitative results was investigated. All parameters investigated were shown to impact milk allergen detection by means of ELISA. Copyright © 2011 Elsevier Ltd. All rights reserved.
Is there a risk of filarial infection during long-term missions in Haiti?
Weitzel, Thomas; Rosas, Reinaldo; Fica, Alberto; Dabanch, Jeannette; Polanco, Myriam; Egaña, Alicia; Triantafilo, Vjera; Pfarr, Kenneth; Hoerauf, Achim; Reiter-Owona, Ingrid
2016-01-01
Haiti has the highest prevalence of lymphatic filariasis (Wuchereria bancrofti) in the Western Hemisphere. Still, the risk of filarial infection for long-term visitors such as humanitarian aid workers or military personnel is uncertain. The presented study analyzed the exposure to W. bancrofti in Chilean participants of the UN Stabilization Mission in Haiti (MINUSTAH) in 2011. Blood samples collected from 531 participants were screened for antifilarial antibodies by IgG ELISA, and, if positive, analyzed by immunofluorescence assay (IFA), IgG4 ELISA, Real-Time PCR, and circulating filarial antigen (CFA) card test. ELISA screening was positive in 10 cases. Seroconversion occurred in only two cases (0.38%) based on ELISA values determined in samples taken before and after deployment. Positive IgG ELISA values could not be confirmed by IFA and IgG4 ELISA. Real-Time PCR and CFA testing did not reveal the presence of filaria. Our data indicate that in the examined cohort of MINUSTAH participants in 2011, the risk of filarial exposure or infection was low. Copyright © 2015 Elsevier Ltd. All rights reserved.
Schvartz, Gili; Epp, Tasha; Burgess, Hilary J; Chilton, Neil B; Pearl, David L; Lohmann, Katharina L
2015-06-01
Equine granulocytic anaplasmosis (EGA) and Lyme borreliosis (LB) are an emerging concern in Canada. We estimated the seroprevalence of EGA and equine LB by testing 376 convenience serum samples from 3 provinces using a point-of-care SNAP(®) 4Dx(®) ELISA (IDEXX Laboratories, Westbrook, Maine, USA), and investigated the agreement between the point-of-care ELISA and laboratory-based serologic tests. The estimated seroprevalence for EGA was 0.53% overall (0.49% in Saskatchewan, 0.71% in Manitoba), while the estimated seroprevalence for LB was 1.6% overall (0.49% in Saskatchewan, 2.86% in Manitoba). There was limited agreement between the point-of-care ELISA and an indirect fluorescent antibody test for EGA (kappa 0.1, PABAK 0.47) and an ELISA/Western blot combination for LB (kappa 0.23, PABAK 0.71). While the SNAP(®) 4Dx(®) ELISA yielded expected seroprevalence estimates, further evaluation of serologic tests for the purposes of disease exposure recognition may be needed.
A globotetraosylceramide (Gb₄) receptor-based ELISA for quantitative detection of Shiga toxin 2e.
Togashi, Katsuhiro; Sasaki, Shiho; Sato, Wataru
2015-08-01
Currently, no simple assays are available for routine quantitative detection of Escherichia coli-produced Shiga toxin 2e (Stx2e) that causes porcine edema disease. Here, we present a novel quantitative detection method for Stx2e based on the measurement of Stx2e binding to the specific globotetraosylceramide (Gb4) receptor by ELISA (Gb4-ELISA). No cross-reactivity was found with the other Shiga toxins Stx1 and Stx2, indicating high specificity. When the recombinant Stx2e B subunit (Stx2eB) was used, the absorbance measured by Gb4-ELISA increased linearly with Stx2eB concentration in the range of 20-2,500 ng/ml. The Gb4-ELISA method can be easily performed, suggesting that it would be a useful diagnostic tool for porcine edema disease.
Dombrowski, T.R.; Thurman, E.M.; Mohrman, G.B.
1996-01-01
Pesticide concentrations in ground water at Rocky Mountain Arsenal (RMA) near Denver, Colorado, were determined using solid-phase extraction (SPE) gas chromatography/mass spectrometry (GC/MS) procedures and enzyme-linked immunosorbent assay (ELISA) for cyclodiene insecticides and triazine herbicides. Matrix interferences resulted in inconclusive results for some GC/MS analyses due to baseline disturbances and co-elution, but ELISA analyses consistently gave definitive results in a minimum amount of time. ELISA was used initially as a screening method, and pesticide concentrations and plume extents identified by ELISA were confirmed by SPE-GC/MS. A high degree of correlation was seen between results from GC/MS and ELISA methods for the triazine herbicides (correlation coefficient (R2) = 0.99). All areas with high pesticide concentrations were found to be within the boundaries of RMA.
Sampson, J S; Wilkinson, H W; Tsang, V C; Brake, B J
1983-01-01
A semiautomated, kinetic-dependent, enzyme-linked immunosorbent assay (K-ELISA) was adapted to detect serum antibodies to Legionella pneumophila. In a comparative study, 158 human serum samples (79 pairs) were tested by K-ELISA and the standard indirect immunofluorescence assay for determination of antibody levels to L. pneumophila serogroup 1. K-ELISA determinations were made by using a serogroup-specific antigen or a preparation (unfractionated antigen) which contained both common antigen and serogroup-specific reactivity. There was good correlation between the immunofluorescence assay and the K-ELISA by using either antigen, although greater correlation was achieved with the unfractionated antigen (coefficients of correlation, 0.894 with unfractionated antigen and 0.841 with serogroup-specific antigen). These results indicate that the K-ELISA is a reliable alternative to the immunofluorescence assay for serologically diagnosing legionellosis. PMID:6361052
Sampson, J S; Wilkinson, H W; Tsang, V C; Brake, B J
1983-12-01
A semiautomated, kinetic-dependent, enzyme-linked immunosorbent assay (K-ELISA) was adapted to detect serum antibodies to Legionella pneumophila. In a comparative study, 158 human serum samples (79 pairs) were tested by K-ELISA and the standard indirect immunofluorescence assay for determination of antibody levels to L. pneumophila serogroup 1. K-ELISA determinations were made by using a serogroup-specific antigen or a preparation (unfractionated antigen) which contained both common antigen and serogroup-specific reactivity. There was good correlation between the immunofluorescence assay and the K-ELISA by using either antigen, although greater correlation was achieved with the unfractionated antigen (coefficients of correlation, 0.894 with unfractionated antigen and 0.841 with serogroup-specific antigen). These results indicate that the K-ELISA is a reliable alternative to the immunofluorescence assay for serologically diagnosing legionellosis.
Gabriel, Martin; Adomeh, Donatus I; Ehimuan, Jacqueline; Oyakhilome, Jennifer; Omomoh, Emmanuel O; Ighodalo, Yemisi; Olokor, Thomas; Bonney, Kofi; Pahlmann, Meike; Emmerich, Petra; Lelke, Michaela; Brunotte, Linda; Ölschläger, Stephan; Thomé-Bolduan, Corinna; Becker-Ziaja, Beate; Busch, Carola; Odia, Ikponmwosa; Ogbaini-Emovon, Ephraim; Okokhere, Peter O; Okogbenin, Sylvanus A; Akpede, George O; Schmitz, Herbert; Asogun, Danny A; Günther, Stephan
2018-03-01
The classical method for detection of Lassa virus-specific antibodies is the immunofluorescence assay (IFA) using virus-infected cells as antigen. However, IFA requires laboratories of biosafety level 4 for assay production and an experienced investigator to interpret the fluorescence signals. Therefore, we aimed to establish and evaluate enzyme-linked immunosorbent assays (ELISA) using recombinant Lassa virus nucleoprotein (NP) as antigen. The IgM ELISA is based on capturing IgM antibodies using anti-IgM, and the IgG ELISA is based on capturing IgG antibody-antigen complexes using rheumatoid factor or Fc gamma receptor CD32a. Analytical and clinical evaluation was performed with 880 sera from Lassa fever endemic (Nigeria) and non-endemic (Ghana and Germany) areas. Using the IFA as reference method, we observed 91.5-94.3% analytical accuracy of the ELISAs in detecting Lassa virus-specific antibodies. Evaluation of the ELISAs for diagnosis of Lassa fever on admission to hospital in an endemic area revealed a clinical sensitivity for the stand-alone IgM ELISA of 31% (95% CI 25-37) and for combined IgM/IgG detection of 26% (95% CI 21-32) compared to RT-PCR. The specificity of IgM and IgG ELISA was estimated at 96% (95% CI 93-98) and 100% (95% CI 99-100), respectively, in non-Lassa fever patients from non-endemic areas. In patients who seroconverted during follow-up, Lassa virus-specific IgM and IgG developed simultaneously rather than sequentially. Consistent with this finding, isolated IgM reactivity, i.e. IgM in the absence of IgG, had no diagnostic value. The ELISAs are not equivalent to RT-PCR for early diagnosis of Lassa fever; however, they are of value in diagnosing patients at later stage. The IgG ELISA may be useful for epidemiological studies and clinical trials due its high specificity, and the higher throughput rate and easier operation compared to IFA.
Development of Strongylus vulgaris-specific serum antibodies in naturally infected foals.
Nielsen, M K; Vidyashankar, A N; Gravatte, H S; Bellaw, J; Lyons, E T; Andersen, U V
2014-03-01
Strongylus vulgaris is regarded as the most pathogenic helminth parasite infecting horses. Migrating larvae cause pronounced endarteritis and thrombosis in the cranial mesenteric artery and adjacent branches, and thromboembolism can lead to ischemia and infarction of large intestinal segments. A recently developed serum ELISA allows detection of S. vulgaris-specific antibodies during the six-month-long prepatent period. A population of horses has been maintained at the University of Kentucky without anthelmintic intervention since 1979, and S. vulgaris has been documented to be highly prevalent. In 2012, 12 foals were born in this population, and were studied during a 12-month period (March-March). Weekly serum samples were collected to monitor S. vulgaris specific antibodies with the ELISA. Nine colts underwent necropsy at different time points between 90 and 300 days of age. At necropsy, Strongylus spp. and Parascaris equorum were identified to species and stage and enumerated. Initial statistical findings indicate a significant interaction between foal age and ELISA results (p<0.042). All foals had initial evidence of S. vulgaris-directed maternal antibodies transferred in the colostrum, but then remained ELISA negative during their first three months of life. Foals born in February and March became ELISA positive at about 12 weeks of age, while those born in April and May went positive at about 15 and 21 weeks, respectively. Foal date of birth was significantly associated with ELISA results (p<0.0001). This could be explained by birth date-dependent differences in parasite exposure. One foal remained ELISA-negative throughout the course of 30 weeks during the study. A significant association was found between ELISA values and larval S. vulgaris burdens (p<0.0001) as well as a three-way interaction between S. vulgaris, S. edentatus, and P. equorum burdens (p<0.001). A plateau with a subsequent decline in ELISA values corresponded with S. vulgaris larvae leaving the bloodstream and migrating back to the intestine. Copyright © 2013 Elsevier B.V. All rights reserved.
Demorat, Hubert; Lopes, Amanda; Chopin, Dorothée; Delcey, Véronique; Clevenbergh, Philippe; Simoneau, Guy; Evans, John; Mouly, Stéphane; Bergmann, Jean-François; Sellier, Pierre
2018-02-01
Guidelines recommend routine universal HIV testing in adults to reduce the pool of infected patients unaware of their status, without specific recommendations concerning the method. We compared acceptability and feasibility of HIV testing by ELISA tests or rapid tests from finger-stick whole blood. Prospective randomized multi-center study comparing acceptability and feasibility of routine universal HIV testing by ELISA tests, with a charge, subsequently reimbursed by Social Security for affiliated patients, or rapid tests from finger-stick whole blood, without any charge from the patients or the general practitioner for the study. A single investigator performed all interventions. After consent, all adults (18-70 years old) consulting their general practitioner in Paris, France, unaware of their status, were enrolled. Testing was performed immediately for the patients in the rapid test arm; a prescription was given for testing in a lab for the patients in the ELISA arm. The primary endpoint was acceptability of each method. The secondary endpoint was feasibility of each method, assessed one month after the consultation. Two hundred and seventy patients were enrolled: 133 patients in the ELISA arm, 137 in the rapid test arm. Acceptability of the rapid test (92%) was higher than that of the ELISA (63.9%), P<0.0001. Feasibility of the rapid test (100%) was higher than that of the ELISA (50.5%), P<0.0001. A center effect was shown concerning feasibility of ELISA but not concerning feasibility of rapid tests. Rapid testing from finger-stick whole blood is more acceptable and feasible than ELISA for routine universal HIV testing. A larger use of rapid tests, ideally free of charge, by general practitioners could reduce the pool of infected patients unaware of their status. Copyright © 2018 Elsevier Masson SAS. All rights reserved.
Acute undifferentiated fever in India: a multicentre study of aetiology and diagnostic accuracy.
Mørch, Kristine; Manoharan, Anand; Chandy, Sara; Chacko, Novin; Alvarez-Uria, Gerardo; Patil, Suvarna; Henry, Anil; Nesaraj, Joel; Kuriakose, Cijoy; Singh, Ashita; Kurian, Siby; Gill Haanshuus, Christel; Langeland, Nina; Blomberg, Bjørn; Vasanthan Antony, George; Mathai, Dilip
2017-10-04
The objectives of this study were to determine the proportion of malaria, bacteraemia, scrub typhus, leptospirosis, chikungunya and dengue among hospitalized patients with acute undifferentiated fever in India, and to describe the performance of standard diagnostic methods. During April 2011-November 2012, 1564 patients aged ≥5 years with febrile illness for 2-14 days were consecutively included in an observational study at seven community hospitals in six states in India. Malaria microscopy, blood culture, Dengue rapid NS1 antigen and IgM Combo test, Leptospira IgM ELISA, Scrub typhus IgM ELISA and Chikungunya IgM ELISA were routinely performed at the hospitals. Second line testing, Dengue IgM capture ELISA (MAC-ELISA), Scrub typhus immunofluorescence (IFA), Leptospira Microscopic Agglutination Test (MAT), malaria PCR and malaria immunochromatographic rapid diagnostic test (RDT) Parahit Total™ were performed at the coordinating centre. Convalescence samples were not available. Case definitions were as follows: Leptospirosis: Positive ELISA and positive MAT. Scrub typhus: Positive ELISA and positive IFA. Dengue: Positive RDT and/or positive MAC-ELISA. Chikungunya: Positive ELISA. Bacteraemia: Growth in blood culture excluding those defined as contaminants. Malaria: Positive genus-specific PCR. Malaria was diagnosed in 17% (268/1564) and among these 54% had P. falciparum. Dengue was diagnosed in 16% (244/1564). Bacteraemia was found in 8% (124/1564), and among these Salmonella typhi or S. paratyphi constituted 35%. Scrub typhus was diagnosed in 10%, leptospirosis in 7% and chikungunya in 6%. Fulfilling more than one case definition was common, most frequent in chikungunya where 26% (25/98) also had positive dengue test. Malaria and dengue were the most common causes of fever in this study. A high overlap between case definitions probably reflects high prevalence of prior infections, cross reactivity and subclinical infections, rather than high prevalence of coinfections. Low accuracy of routine diagnostic tests should be taken into consideration when approaching the patient with acute undifferentiated fever in India.
Castillo, Daniela S.
2017-01-01
Cow milk protein allergy (CMPA) is the most common childhood food allergy, which can sometimes persist or can newly develop in adulthood with severe symptoms. CMPA's treatment is complete dietary avoidance of milk proteins. To achieve this task, patients have to be aware of milk proteins found as "hidden allergens" in food commodities. In regard to milk proteins, it has been reported that allergenicity of caseins remains unaffected upon heat treatment. For these reasons, we aimed to obtain monoclonal antibodies (mAbs) against native and denatured β-casein, one of the most abundant and antigenic caseins, in order to develop an indirect competitive ELISA (icELISA) to detect and quantify traces of this milk allergen in raw and processed foodstuffs. We developed two specific hybridoma clones, 1H3 and 6A12, which recognized β-casein in its denatured and native conformations by indirect ELISA (iELISA). Cross-reaction analysis by Western blot and iELISA indicated that these mAbs specifically recognized β-casein from bovine and goat milk extracts, while they did not cross-react with proteins present in other food matrixes. These highly specific mAbs enabled the development of sensitive, reliable and reproducible icELISAs to detect and quantify this milk protein allergen in food commodities. The extraction of β-casein from foodstuff was efficiently carried out at 60°C for 15 minutes, using an extraction buffer containing 1% SDS. The present study establishes a valid 1H3 based-icELISA, which allows the detection and quantification -0.29 ppm and 0.80 ppm, respectively- of small amounts of β-casein in raw and processed foods. Furthermore, we were able to detect milk contamination in incurred food samples with the same sensitivity as a commercial sandwich ELISA thus showing that this icELISA constitutes a reliable analytical method for control strategies in food industry and allergy prevention. PMID:28759641
Castillo, Daniela S; Cassola, Alejandro
2017-01-01
Cow milk protein allergy (CMPA) is the most common childhood food allergy, which can sometimes persist or can newly develop in adulthood with severe symptoms. CMPA's treatment is complete dietary avoidance of milk proteins. To achieve this task, patients have to be aware of milk proteins found as "hidden allergens" in food commodities. In regard to milk proteins, it has been reported that allergenicity of caseins remains unaffected upon heat treatment. For these reasons, we aimed to obtain monoclonal antibodies (mAbs) against native and denatured β-casein, one of the most abundant and antigenic caseins, in order to develop an indirect competitive ELISA (icELISA) to detect and quantify traces of this milk allergen in raw and processed foodstuffs. We developed two specific hybridoma clones, 1H3 and 6A12, which recognized β-casein in its denatured and native conformations by indirect ELISA (iELISA). Cross-reaction analysis by Western blot and iELISA indicated that these mAbs specifically recognized β-casein from bovine and goat milk extracts, while they did not cross-react with proteins present in other food matrixes. These highly specific mAbs enabled the development of sensitive, reliable and reproducible icELISAs to detect and quantify this milk protein allergen in food commodities. The extraction of β-casein from foodstuff was efficiently carried out at 60°C for 15 minutes, using an extraction buffer containing 1% SDS. The present study establishes a valid 1H3 based-icELISA, which allows the detection and quantification -0.29 ppm and 0.80 ppm, respectively- of small amounts of β-casein in raw and processed foods. Furthermore, we were able to detect milk contamination in incurred food samples with the same sensitivity as a commercial sandwich ELISA thus showing that this icELISA constitutes a reliable analytical method for control strategies in food industry and allergy prevention.
Panda, Rakhi; Zoerb, Hans F; Cho, Chung Y; Jackson, Lauren S; Garber, Eric A E
2015-06-01
In 2013 the U.S. Food and Drug Administration (FDA) defined the term ''gluten-free'' and identified a gap in the analytical methodology for detection and quantification of gluten in foods subjected to fermentation and hydrolysis. To ascertain the ability of current enzyme-linked immunosorbent assays (ELISAs) to detect and quantify gluten in fermented and hydrolyzed products, sorghum beer was spiked in the initial phases of production with 0, 20, and 200 μg/ml wheat gluten, and samples were collected throughout the beer production process. The samples were analyzed using five sandwich ELISAs and two competitive ELISAs and by sodium dodecyl sulfate-polyacrylamide gel electrophoresis with Western analysis employing four antibodies (MIoBS, R5, G12, and Skerritt). The sensitivity of the MIoBS ELISA (0.25 ppm) enabled the reliable detection of gluten throughout the manufacturing process, including fermentation, when the initial concentration of 20 μg/ml dropped to 2 μg/ml. The R5 antibody-based and G12 antibody-based sandwich ELISAs were unable to reliably detect gluten, initially at 20 μg/ml, after the onset of production. The Skerritt antibody-based sandwich ELISA overestimated the gluten concentration in all samples. The R5 antibody-based and G12 antibody-based competitive ELISAs were less sensitive than the sandwich ELISAs and did not provide accurate results for quantifying gluten concentration. The Western analyses were able to detect gluten at less than 5 μg/ml in the samples and confirmed the results of the ELISAs. Although further research is necessary before all problems associated with detection and quantification of hydrolyzed and fermented gluten are resolved, the analytical methods recommended by the FDA for regulatory samples can detect ≥ 20 μg/ml gluten that has undergone brewing and fermentation processes associated with the manufacture of beer.
Aspergillus antigen testing in bone marrow transplant recipients
Williamson, E; Oliver, D; Johnson, E; Foot, A; Marks, D; Warnock, D
2000-01-01
Aims—To assess the clinical usefulness of a commercial aspergillus antigen enzyme linked immunosorbent assay (ELISA) in the diagnosis of invasive aspergillosis (IA) in bone marrow transplant recipients, and to compare it with a commercial latex agglutination (LA) test. Methods—In total, 2026 serum samples from 104 bone marrow transplant recipients were tested. These comprised 67 sera from seven patients who had died with confirmed IA, 268 sera from nine patients who had died with suspected IA, and 1691 sera from 88 patients with no clinical, radiological, or microbiological signs of IA. Results—The ELISA was more sensitive than the LA test. All patients who were ELISA positive were also LA positive, and a positive LA result never preceded a positive ELISA. Twelve of 16 patients with confirmed or suspected IA were ELISA positive on two or more occasions, compared with 10 of 15 who were LA positive. ELISA was positive before LA in five patients (range, 2–14 days), and became positive on the same day in the remainder. Aspergillus antigen was detected by ELISA a median of 15 days before death (range, 4–233). Clinical and/or radiological evidence of IA was noted in all patients, and a positive ELISA was never the sole criterion for introduction of antifungal treatment. Two samples (one from each of two patients without IA) gave false positive results. Conclusions—The aspergillus ELISA is a specific indicator of invasive aspergillosis if the criterion of two positive samples is required to confirm the diagnosis. However, the test is insufficiently sensitive to diagnose aspergillosis before other symptoms or signs are apparent, and hence is unlikely to lead to earlier initiation of antifungal treatment. It is therefore unsuitable for screening of asymptomatic patients at risk of invasive aspergillosis, but does have a useful role in confirming the diagnosis in symptomatic patients. Key Words: invasive aspergillosis • aspergillus antigen • Platelia enzyme linked immunosorbent assay PMID:10889818
Shiraishi, Rikiya; Nishiguchi, Akiko; Tsukamoto, Kenji; Muramatsu, Masatake
2012-09-01
We evaluated the utility of 5 commercial enzyme-linked immunosorbent assay (ELISA) kits for detecting antibodies to avian influenza viruses. The sensitivities and specificities of the ELISA kits were compared with those of the agar gel precipitation (AGP) and hemagglutination-inhibition (HI) tests. The results suggest that some ELISA kits might not be suitable for monitoring during the early stages of avian influenza virus infections. Therefore, ELISA kits should only be used in conjunction with a profound knowledge about monitoring of avian influenza.
Apollonio, Luigino G; Whittall, Ian R; Pianca, Dennis J; Kyd, Jennelle M; Maher, William A
2007-05-01
The aim of this study was to evaluate the Bio-Quant Direct ELISA assays for amphetamine and methamphetamine in the routine presumptive screening of biological fluids. Standard concentration curves of the target analytes were assayed to assess sensitivity, and known concentrations of common amphetamine-type substances (ephedrine, pseudoephedrine, phentermine), designer analogues (MDA, MDMA, MDEA, MBDB, PMA, 4-MTA, 2CB), and putrefactive amines (phenylethylamine, putrescine, tryptamine, tyramine) were analyzed to determine cross-reactivity. Results of the standard curve studies show the capacity of both Direct ELISA kits to confidently detect down to 3 ng/mL interday (PBS matrix; CVs 6.3-15.5%). Cross-reactivity relative to that of 50 ng/mL preparations of the target compounds demonstrated that the Direct ELISA kit for amphetamine also detected MDA (282%), PMA (265%), 4-MTA (280%), and phentermine (61%), and the Direct ELISA for methamphetamine also assayed positive for MDMA (73%), MDEA (18%), pseudoephedrine (19%), MBDB (8%), and ephedrine (9%). Matrix studies demonstrated that both ELISA kits could be applied to screening of blood, urine, and saliva to a concentration of 6 ng/mL or lower. In conclusion, the Bio-Quant Direct ELISA kits for amphetamine and methamphetamine are fast and accurate and have demonstrated themselves to be useful tools in routine toxicological testing.
2013-01-01
Quantitative analysis of protein biomarkers in plasma is typically done by ELISA, but this method is limited by the availability of high-quality antibodies. An alternative approach is protein immunoprecipitation combined with multiple reaction monitoring mass spectrometry (IP-MRM). We compared IP-MRM to ELISA for the analysis of six colon cancer biomarker candidates (metalloproteinase inhibitor 1 (TIMP1), cartilage oligomeric matrix protein (COMP), thrombospondin-2 (THBS2), endoglin (ENG), mesothelin (MSLN) and matrix metalloproteinase-9 (MMP9)) in plasma from colon cancer patients and noncancer controls. Proteins were analyzed by multiplex immunoprecipitation from plasma with the ELISA capture antibodies, further purified by SDS-PAGE, digested and analyzed by stable isotope dilution MRM. IP-MRM provided linear responses (r = 0.978–0.995) between 10 and 640 ng/mL for the target proteins spiked into a “mock plasma” matrix consisting of 60 mg/mL bovine serum albumin. Measurement variation (coefficient of variation at the limit of detection) for IP-MRM assays ranged from 2.3 to 19%, which was similar to variation for ELISAs of the same samples. IP-MRM and ELISA measurements for all target proteins except ENG were highly correlated (r = 0.67–0.97). IP-MRM with high-quality capture antibodies thus provides an effective alternative method to ELISA for protein quantitation in biological fluids. PMID:24224610
Sunwoo, Hoon; Gujral, Naiyana; Suresh, Mavanur
2011-01-01
Two effective competitive and double antibody sandwich ELISA based on monoclonal (MAb) and chicken egg yolk IgY antibodies were developed to determine lactoferrin (LF) content in infant and milk formulas. Leghorn laying hens were immunized with purified bovine and human LFs to produce anti-bovine LF and anti-human LF IgY antibody in the egg yolk. After 5-8 weeks of the immunization, anti-LF IgY was extracted and analyzed by ELISA. Specific IgY antibodies against LFs cross reacted with human and bovine LFs, examined by ELISA and western-blot assay. Such cross-reactivity suggested the presence of common antigenic determinants between human and bovine LFs. An indirect competitive ELISA was preferred to quantify LF in milk and infant formulas, since the range of detection is 3.125-50 μg/mL, which is broader compared to the biotinylated ELISA system (5-50 ng/mL). As per the indirect competitive ELISA system, IgY at a concentration of the 150 μg/mL was incubated with various concentrations of bovine LF ranged from 0.003-100 μg/mL. The immunoassay was used to estimate the total bovine LF content in the milk samples and infant formulas, ranging from 49.28-80.96 μg/mL and 29.92-60.00 μg/mL, respectively.
Detection of Bovine IgG Isotypes in a PPA-ELISA for Johne's Disease Diagnosis in Infected Herds
Fernández, Bárbara; Gilardoni, Liliana Rosa; Jolly, Ana; Colavecchia, Silvia Beatriz; Paolicchi, Fernando Alberto; Mundo, Silvia Leonor
2012-01-01
Johne's Disease or Paratuberculosis is a chronic granulomatous enteritis disease affecting ruminants. Detection of subclinically infected animals is difficult, hampering the control of this disease. The aim of this work was to evaluate the performance of detection of IgG isotypes in a PPA-ELISA to improve the recognition of cattle naturally infected with Map in different stages. A total of 108 animals from Tuberculosis-free herds were grouped as follows: exposed (n = 30), subclinically infected (n = 26), clinically infected (n = 14), and healthy controls (n = 38). Receiver-operating characteristic (ROC) curves of isotypes/PPA-ELISAs were constructed and areas under the curves were compared to evaluate the performance of each test. Our study demonstrated that the conventional PPA-ELISA (detecting IgG) is the best to identify clinically infected animals with high sensitivity (92.9%) and specificity (100%). Meanwhile, IgG2/PPA-ELISA improved the number of subclinically infected cattle detected as compared with conventional IgG/PPA-ELISA (53.8 versus 23.1%). In addition, it had the maximum sensitivity (65.0%, taking into account all Map-infected cattle). In conclusion, the combination of IgG and IgG2/PPA-ELISAs may improve the identification of Map-infected cattle in different stages of disease. The usefulness of IgG2 detection in serological tests for Johne's Disease diagnosis should be further evaluated. PMID:22792511
Detection of Bovine IgG Isotypes in a PPA-ELISA for Johne's Disease Diagnosis in Infected Herds.
Fernández, Bárbara; Gilardoni, Liliana Rosa; Jolly, Ana; Colavecchia, Silvia Beatriz; Paolicchi, Fernando Alberto; Mundo, Silvia Leonor
2012-01-01
Johne's Disease or Paratuberculosis is a chronic granulomatous enteritis disease affecting ruminants. Detection of subclinically infected animals is difficult, hampering the control of this disease. The aim of this work was to evaluate the performance of detection of IgG isotypes in a PPA-ELISA to improve the recognition of cattle naturally infected with Map in different stages. A total of 108 animals from Tuberculosis-free herds were grouped as follows: exposed (n = 30), subclinically infected (n = 26), clinically infected (n = 14), and healthy controls (n = 38). Receiver-operating characteristic (ROC) curves of isotypes/PPA-ELISAs were constructed and areas under the curves were compared to evaluate the performance of each test. Our study demonstrated that the conventional PPA-ELISA (detecting IgG) is the best to identify clinically infected animals with high sensitivity (92.9%) and specificity (100%). Meanwhile, IgG2/PPA-ELISA improved the number of subclinically infected cattle detected as compared with conventional IgG/PPA-ELISA (53.8 versus 23.1%). In addition, it had the maximum sensitivity (65.0%, taking into account all Map-infected cattle). In conclusion, the combination of IgG and IgG2/PPA-ELISAs may improve the identification of Map-infected cattle in different stages of disease. The usefulness of IgG2 detection in serological tests for Johne's Disease diagnosis should be further evaluated.
An ELISA using recombinant TmHSP70 for the diagnosis of Taenia multiceps infections in goats.
Wang, Yu; Nie, Huaming; Gu, Xiaobin; Wang, Tao; Huang, Xing; Chen, Lin; Lai, Weimin; Peng, Xuerong; Yang, Guangyou
2015-09-15
Infections with the tapeworm Taenia multiceps are problematic for ruminant farming worldwide. Here we develop a novel and rapid method for serodiagnosis of T. multiceps infections via an indirect ELISA (iELISA) that uses a heat shock protein, namely, TmHSP70. We extracted the total RNA of T. multiceps from the protoscoleces of cysts dissected from the brains of infected goats. Subsequently, we successfully amplified, cloned and expressed the TmHSP70 gene in Escherichia coli BL21 (DE3). Western blot analysis showed that the recombinant protein (∼34 kDa molecular weight) was recognized by the coenurosis positive serum. Given these initial, robust immunogenic properties for recombinant TmHSP protein, we assessed the ELISA-based serodiagnostic potential of this gene. The indirect ELISA was then optimized to 2.70 μg/well dilution for antigen and 1:80 dilution for serum,while the cut-off value is 0.446. We report that our novel TmHSP ELISA detected T. multiceps sera with a sensitivity of 1:10240 and a specificity of 83.3% (5/6). In a preliminary application, this assay correctly confirmed T. multiceps infection in 30 infected goats, consistent with the clinical examination. This study has revealed that our novel iELISA, which uses the rTmHSP protein, provides a rapid test for diagnosing coenurosis. Copyright © 2015 Elsevier B.V. All rights reserved.
Marinović, Branka; Fabris, Zrinka; Lipozencić, Jasna; Stulhofer Buzina, Daska; Lakos Jukić, Ines
2010-01-01
Pemphigus vulgaris (PV) and pemphigus foliaceus (PF) are autoimmune blistering diseases characterized by intraepidermal separation as the result of autoantibodies directed to desmoglein 1 and desmoglein 3, adhesion molecules that have a pathogenic role in blister formation. Both PV and PF are diagnosed according to clinical picture, histopathologic, immunopathologic and molecular biologic features. In the present study, the value of indirect immunofluorescence (IIF) and enzyme linked immunosorbent assay (ELISA) for desmoglein 1 (Dsg 1) and desmoglein 3 (Dsg 3) at baseline visit was compared. The study was performed as a retrospective study that included 22 patients, 19 of them with PV and three with PF. Patient sera were tested with IIF and Dsg 1 and Dsg 3 ELISA. In the group of 19 PV patients, 12 patients had positive IIF, Dsg 3 and Dsg 1 ELISA; two had positive IIF and positive anti Dsg 3 but negative anti Dsg 1; three had negative IIF but positive both Dsg 1 and Dsg 3 antibodies; and two had negative IIF and Dsg 1 but positive Dsg 3 antibodies. In the group of PF patients, all three patients had positive IIF, positive Dsg 1 ELISA and negative Dsg 3 ELISA. Results of our study supported previous reports confirming Dsg 1 and Dsg 3 ELISA to be a sensitive and specific tool for the diagnosis of PV and PF.
He, Haining; Li, Youquan; Liu, Junlong; Liu, Zhijie; Yang, Jifei; Liu, Aihong; Chen, Ze; Ren, Qiaoyun; Guan, Guiquan; Liu, Guangyuan; Luo, Jianxun; Yin, Hong
2016-07-01
Theileria is a tick-borne, intracellular protozoan parasite of worldwide economic and veterinary importance in small ruminants. Here, an enzyme-linked immunosorbent assay (ELISA) was developed based on Theileria luwenshuni recombinant surface protein (rTlSP) and was used in the standardization and validation of an ELISA for the detection of circulating antibodies against ovine and caprine theileriosis. A total of 233 sera samples were used for the calculation of the cut-off value which served as a threshold between the positive and the negative sera. When the positive threshold was chosen as 19% of the specific mean antibody rate, the specificity was 97.9%, and the sensitivity was 97.1%. There was a cross-reaction with sera against Theileria uilenbergi and Theileria ovis, and no cross-reaction with sera against Babesia spp. in the ELISA and Western blotting. Two hundred forty samples collected from sheep in Gansu province were detected with blood smears and ELISA, respectively. The results showed that the positive rate of Theileria infection in Gansu province were 63.75% with rTlSP-ELISA, and 46.67% with blood smears, respectively. Our test proved that the rTlSP ELISA is suitable to diagnose Theileria infection and could be used in serological surveys to map out the prevalence of ovine and caprine theileriosis. Copyright © 2016 Elsevier Inc. All rights reserved.
Investigation of enrofloxacin residues in broiler tissues using ELISA and LC-MS/MS.
Panzenhagen, Pedro Henrique N; Aguiar, Waldemir S; Gouvêa, Raquel; de Oliveira, Andréa M G; Barreto, Fabiano; Pereira, Virgínia L A; Aquino, Maria Helena C
2016-01-01
This study investigated the efficiency of an enrofloxacin ELISA test kit to detect the presence of enrofloxacin residues in broiler tissues compared with LC-MS/MS. Broiler tissues from 72 samples consisting of 60 breast muscle, six pools of livers (500 g each) and six pools of kidneys (500 g each) were obtained from six different slaughterhouses. Breast muscle from 10 carcasses and pools of livers and kidneys from approximately 200 carcasses of the same flock were collected from each slaughterhouse. ELISA and HPLC were used to identify and quantify the contamination of the samples with enrofloxacin. A total of 72% of the analysed samples contained enrofloxacin residues detected by the ELISA and 22.2% were detected by LC-MS/MS. The mean values of enrofloxacin contamination found in chicken breast by ELISA and HPLC were 8.63 and 12.25 μg kg(-1), respectively. None of the samples exceeded the maximum limit of 100 μg kg(-1) by both methods set by the European Union as well as the Brazilian Agriculture Ministry. All positive samples for enrofloxacin residues detected by LC-MS/MS were also positive by ELISA. These data confirm the efficiency of the ELISA test, and suggest its use as a screening method for enrofloxacin residues in poultry tissues due to its quick results, low price and ease of applicability.
USDA-ARS?s Scientific Manuscript database
Food contamination caused by veterinary drug residues is a world-wide public health concern and requires continuous monitoring. In this paper, we describe a biotin–streptavidin-amplified ELISA (BA-ELISA) for detecting pirlimycin residues in beef, milk, and honey. The IC50 value of the BA-ELISA was...
Diagnosis of theileria equi infections in horses in the Azores using cELISA and nested PCR
USDA-ARS?s Scientific Manuscript database
Equine piroplasmosis is a tick-borne disease of equids that is often caused by the parasite Theileria equi. We applied competitive ELISA (cELISA) and nested PCR diagnostic methods to detect this parasite in horses by screening 162 samples from mainland Portugal where the parasite is endemic, and 143...
2016-10-01
Program (ATP) Quality MS2 coat protein (MS2CP) Enzyme-linked immunosorbent assay ( ELISA ) 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF...3 2.6 Thermal Stress Test............................................................................................4 2.7 ELISA ...7 3.4 DSC Results .....................................................................................................10 3.5 ELISA
77 FR 6971 - Establishment of User Fees for Filovirus Testing of Nonhuman Primate Liver Samples
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-10
... (ELISA) or other appropriate methodology. Each specimen will be held for six months. After six months.../CDC's analysis of costs to the Government is based on the current methodology (ELISA) used to test NHP... different methodology or changes in the availability of ELISA reagents will affect the amount of the user...
2016-03-01
performance in an enzyme-linked immunosorbent assay ( ELISA ), with little regard for quantification of the full spectrum of variables affecting antibody...Program (ATP) Quality MS2 coat protein (MS2CP) Enzyme-linked immunosorbent assay ( ELISA ) 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT...5 2.7 ELISA ................................................................................................................5
Suryawanshi, Rahul D; Malik, Satya Veer Singh; Jayarao, Bhushan; Chaudhari, Sandeep P; Savage, Emily; Vergis, Jess; Kurkure, Nitin V; Barbuddhe, Sukhadeo B; Rawool, Deepak B
2017-06-01
The present study for the first time evaluates the serodiagnostic efficacy of two recombinant antigens namely, listeriolysin O (rLLO) and phosphatidyl-inositol phospholipase C (rPI-PLC). Indirect ELISA with the above recombinant antigens was used on samples collected from bovines (n=106), goats (n=138) and pigs (n=92) having either a history of abortion, emaciation and/or apparently healthy animals. Isolation of Listeria was attempted from the blood samples using USDA-FSIS method. On screening of test sera by rLLO-based ELISA, antibodies against anti-listeriolysin O (ALLO) were observed in goats (22.46%), bovines (15.10%) and pigs (16.31%). As advocated, after adsorption of positive serum samples with streptolysin O (SLO), the seropositivity for ALLO was marginally reduced (p>0.05) in goats (21.73%) and bovines (10.38%), whereas, in pigs the reduction (5.43%) was significant (p<0.05). On the contrary, rPI-PLC-based ELISA revealed higher non-specific seropositivity for antilisterial antibodies in goats (45.65%), bovines (31.13%) and pigs (8.69%). Further, on comparing the seropositivity with isolation rate, of the 16 animals that were culturally-positive for L. monocytogenes, 15 showed ALLO positivity in unadsorbed as well as SLO-adsorbed sera by rLLO-based ELISA, however, rPI-PLC-based ELISA could detect seropositivity in only 5 animals. Moreover, rPI-PLC-based ELISA also showed seropositivity in those animals (7/30) that were culturally positive for other Listeria spp. In conclusion, rLLO can serve as a better antigen than rPI-PLC in ELISA for the serodiagnosis of listeriosis in animals; however, prior adsorption of test sera with SLO is required to avoid false positive results. Copyright © 2017 Elsevier B.V. All rights reserved.
Wells, Scott J.; Collins, Michael T.; Faaberg, Kay S.; Wees, Carrie; Tavornpanich, Saraya; Petrini, Kristine R.; Collins, James E.; Cernicchiaro, Natalia; Whitlock, Robert H.
2006-01-01
A high-throughput TaqMan PCR assay for detection of bovine paratuberculosis was evaluated by using fecal samples from 1,808 dairy cattle in seven naturally infected herds and 347 dairy cattle in seven herds considered free of paratuberculosis. Fecal, blood, and milk samples were submitted to laboratories where the PCR-based assay, three different fecal culture procedures for Mycobacterium avium subsp. paratuberculosis (centrifugation, sedimentation, and the BACTEC filter concentration method), two serologic enzyme-linked immunosorbent assays (ELISAs), and one milk ELISA were performed. Results from testing of dairy cattle in herds free of M. avium subsp. paratuberculosis showed that the PCR assay's specificity was 99.7%. Twenty-three percent of the dairy cows that were fecal culture positive by at least one of the three methods were positive by the PCR assay. By Bayesian non-“gold standard” analysis methods, the TaqMan PCR assay had a higher specificity than the serum ELISAs (99.3%; 95% confidence interval [CI] = 98.6 to 99.7%) and a test sensitivity similar to that of the serum ELISAs (29%; 95% CI = 24 to 35%). By classical methods, the estimated relative sensitivity of the fecal PCR assay was 4% for light and moderate fecal shedders (compared to 12 to 13% for the ELISAs) and 76% for heavy fecal shedders (compared to 67% for the milk ELISA). The PCR assay has higher sensitivity for detection of heavy fecal shedders than the evaluated milk ELISA but lower sensitivity than a serum or milk ELISA for detection of light and moderate fecal shedders. This assay can be used as a quick test for detection of cattle with heavy fecal shedding, those cattle with the highest risk of transmitting infection to susceptible cattle. PMID:16928884
Venkataramana, M.; Rashmi, R.; Uppalapati, Siva R.; Chandranayaka, S.; Balakrishna, K.; Radhika, M.; Gupta, Vijai K.; Batra, H. V.
2015-01-01
In the present study, generation and characterization of a highly specific monoclonal antibody (mAb) against Ochratoxin A (OTA) was undertaken. The generated mAb was further used to develop a simple, fast, and sensitive sandwich dot-ELISA (s-dot ELISA) method for detection of OTA from contaminated food grain samples. The limit of detection (LOD) of the developed enzyme-linked immunosorbent assay (ELISA) method was determined as 5.0 ng/mL of OTA. Developed method was more specific toward OTA and no cross reactivity was observed with the other tested mycotoxins such as deoxynivalenol, fumonisin B1, or aflatoxin B1. To assess the utility and reliability of the developed method, several field samples of maize, wheat and rice (n = 195) collected from different geographical regions of southern Karnataka region of India were evaluated for the OTA occurrence. Seventy two out of 195 samples (19 maize, 38 wheat, and 15 rice) were found to be contaminated by OTA by s-dot ELISA. The assay results were further co-evaluated with conventional analytical high-performance liquid chromatography (HPLC) method. Results of the s-dot ELISA are in concordance with HPLC except for three samples that were negative for OTA presence by s-dot ELISA but found positive by HPLC. Although positive by HPLC, the amount of OTA in the three samples was found to be lesser than the accepted levels (>5 μg/kg) of OTA presence in cereals. Therefore, in conclusion, the developed s-dot ELISA is a better alternative for routine cereal based food and feed analysis in diagnostic labs to check the presence of OTA over existing conventional culture based, tedious analytical methods. PMID:26074899
Espirito-Santo, M C C; Sanchez, M C A; Sanchez, A R; Alvarado-Mora, M V; Castilho, V L P; Gonçalves, E M N; Luna, E J A; Gryschek, R C B
2014-12-01
Schistosomiasis is a major public health concern, with 200 million people infected worldwide. In Brazil, this disease has been reported in 19 states, and its prevalence in the city of Barra Mansa in Rio de Janeiro State is 1 %. The parasitological diagnostic methods currently available in these areas lack sensitivity; however, enzyme-linked immunosorbent assays (ELISAs) have been employed successfully for the diagnosis of schistosomiasis by using antibodies against antigens of Schistosoma mansoni adult worms and eggs, and for the detection of circulating antigens. The objective of this study was to determine systematically the prevalence of S. mansoni infection in the peripheral areas of Barra Mansa. A cross-sectional study was conducted from April to December 2011 by using probabilistic sampling that collected 610 fecal samples and 612 serum samples. ELISA-IgG with total extracts and ELISA-IgM with trichloroacetic acid-soluble fractions were employed to detect antibodies against S. mansoni and were compared with the Kato-Katz and Hoffman parasitological techniques. Among the individuals studied, anti-S. mansoni antibodies were detected in 11.16 % (n = 71) by ELISA-IgG and in 20.75 % (n = 132) by ELISA-IgM, while the parasitological techniques showed 0.82 % (n = 5) positivity. The agreement between the two ELISA tests was 85.38 % (n = 543), and 8.65 % (n = 55) of the serum samples showed positive results in both tests. The higher positivity of the ELISA-IgM test corroborates the results of previous reports and indicates that the test may be a useful tool in epidemiological studies, particularly in areas of low endemicity for S. mansoni.
Tanpradist, S; Tharavanij, S; Yamokgul, P; Bualombai, P; Wongchotigul, V; Singhasivanon, P; Patarapotikul, J; Thammapalerd, N; Prasittisuk, C; Tantanasrikul, S
1995-03-01
Monoclonal antibody-based ELISA and QBC (quantitative buffy coat analysis) were tested in two endemic areas with low and high incidence of malaria in Kanchanaburi Province, West Thailand with annual parasite incidence in 1992 of 119 and 5 per 1,000 population, respectively. The numbers of individuals positive by thick blood film examination (TBF) for P. falciparum with or without P. vivax, and P. vivax only were 82 and 69, respectively. The detection limit of ELISA was 10 parasites/10(6) red blood cells (RBC) (0.001% parasitemia). Of 1,095 individuals involved in the study at the beginning of the study, ELISA showed sensitivity, specificity, positive predictive value and negative predictive value of 78.1%, 94.9%, 72% and 98.1%, respectively. Nine of 18 (50%) TBF-positive but ELISA-positive individuals had parasitemia of less than 10 parasites/10(6) RBC. High and low incidence areas did not affect the validity of our result. Regression analysis showed good correlation between log parasitemia and ELISA percent OD increase (Y = 0 + 64.9*logX, r = 0.65), and agreement between TBF and ELISA results was 95.9%. In a fortnightly follow-up, in 82 TBF-positive individuals, both ELISA and TBF positive rates correlatively declined with agreement of 96.3%. With samples taken on the first day of the study, the TBF and QBC results were also correlated with agreement of 95.8% for P. falciparum, 95.6% for P. vivax. During 8 week follow-up involving altogether 191 samples, agreement between TBF and QBC results were 87.4% for P. falciparum. QBC detected more cases with P. falciparum infections but detected smaller number of cases with P. vivax infections.
Cuzzubbo, Andrea J.; Vaughn, David W.; Nisalak, Ananda; Solomon, Tom; Kalayanarooj, Siripen; Aaskov, John; Dung, Nguyen Minh; Devine, Peter L.
1999-01-01
The performances of the MRL dengue fever virus immunoglobulin M (IgM) capture enzyme-linked immunosorbent assay (ELISA) and the PanBio Dengue Duo IgM capture and IgG capture ELISA were compared. Eighty sera from patients with dengue virus infections, 24 sera from patients with Japanese encephalitis (JE), and 78 sera from patients with nonflavivirus infections, such as malaria, typhoid, leptospirosis, and scrub typhus, were used. The MRL test showed superior sensitivity for dengue virus infections (94 versus 89%), while the PanBio test showed superior specificity for JE (79 versus 25%) and other infections (100 versus 91%). The PanBio ELISA showed better overall performance, as assessed by the sum of sensitivity and specificity (F value). When dengue virus and nonflavivirus infections were compared, F values of 189 and 185 were obtained for the PanBio and MRL tests, respectively, while when dengue virus infections and JE were compared, F values of 168 and 119 were obtained. The results obtained with individual sera in the PanBio and MRL IgM ELISAs showed good correlation, but this analysis revealed that the cutoff value of the MRL test was set well below that of the PanBio test. Comparing the sensitivity and specificity of the tests at different cutoff values (receiver-operator analysis) revealed that the MRL and PanBio IgM ELISAs performed similarly in distinguishing dengue virus from nonflavivirus infections, although the PanBio IgM ELISA showed significantly better distinction between dengue virus infections and JE. The implications of these findings for the laboratory diagnosis of dengue are discussed. PMID:10473522
Opriessnig, Tanja; Hemann, Michelle; Johnson, John K; Heinen, Sheila; Giménez-Lirola, Luis G; O'Neill, Kevin C; Hoang, Hai; Yoon, Kyoung-Jin; Gottschalk, Marcelo; Halbur, Patrick G
2013-01-01
Accurate diagnosis of exposure to Actinobacillus pleuropneumoniae is important for maintaining negative farms. In the present study, the ability of a dual-plate complement fixation (CF) assay and 3 commercially available enzyme-linked immunosorbent assays (ELISAs; quad-plate ELISA-1, single-plate ELISA-2, and single-plate ELISA-3) in detecting serological evidence of A. pleuropneumoniae exposure was compared using serum samples of experimentally infected or vaccinated pigs, or field samples from the United States. Forty-two pigs were divided into groups of 2 pigs and were inoculated with 1 of 15 A. pleuropneumoniae strains representing all known serovars of A. pleuropneumoniae, or with Actinobacillus suis, or were vaccinated with a bacterin containing A. pleuropneumoniae serovar 1, 3, 5, or 7. Serum samples collected at the day of inoculation or vaccination and 7, 14, 21, and 28 days later were used to compare the assays. On samples from experimentally infected pigs, the dual-plate CF assay, quad-plate ELISA-1, single-plate ELISA-2, and single-plate ELISA-3 had sensitivities of 0.46, 0.74, 0.13, and 0.13 and specificities of 0.90, 1.0, 1.0, and 1.0, respectively. Vaccinated pigs were identified only by the dual-plate CF assay and the quad-plate ELISA-1. In addition, 90 serum samples with unknown A. pleuropneumoniae exposure collected under field conditions were tested with all assays. The agreement of the 4 assays on field samples was slight to fair. While several assays are available for demonstration of A. pleuropneumoniae exposure, differences in assay targets complicate test choices. Decisions on which assay or combination of assays to use depend on the specific reasons for running the assays.
ELISA assays and alcohol: increasing carbon chain length can interfere with detection of cytokines
von Maltzan, Kristine; Pruett, Stephen B.
2010-01-01
Enzyme-linked immunosorbent assays (ELISA) are frequently used in studies on cytokine production in response to treatment of cell cultures or laboratory animals. When an ELISA assay is performed on cell culture supernatants, samples often contain the treatment agents. The purpose of the present study was to determine if some of the agents evaluated might inhibit cytokine detection by interfering with the ELISA, leaving the question of whether cytokine production was inhibited unanswered. Mouse and human cytokine ELISA kits from BD Biosciences were used according to the manufacturer’s instructions. Cytokine proteins were subjected to one to five carbon alcohols at 86.8 mM (methanol, ethanol, 1-propanol, 2-propanol, n-butanol, and n-pentanol). After treating cell cultures with alcohols of different carbon chain lengths, we found that some of the alcohols interfered with measurement of some cytokines by ELISA, thus making their effects on cytokine production by cells in culture unclear. Increasing carbon chain length of straight chain alcohols positively correlated with their ability to inhibit detection of TNF-α and IL-10, but not with the detection of IL-6, IL-8, and IL-12. To avoid misinterpretation of treatment effects, ELISA assays should be tested with the reference protein and the treatment agent first, before testing biological samples. These results along with other recent results we obtained using circular dichroism indicate that alcohols with 2 or more carbons can directly alter protein conformation enough to disrupt binding in an ELISA (shown in the present study) or to inhibit ligand induced conformational changes (results not shown). Such direct effects have not been given enough consideration as a mechanism of ethanol action in the immune system. PMID:20843633
Chouicha, Nadira; Marks, Stanley L
2006-03-01
Clostridium difficile-associated-diarrhea (CDAD) is a nosocomial infection in dogs. Diagnosis of this infection is dependent on clinical signs of disease supported by laboratory detection of C. difficile toxins A or B, or both, in fecal specimens via enzyme-linked immunosorbent assay (ELISA). Unfortunately, to the authors' knowledge, commercially available ELISAs have not been validated in dogs to date. We evaluated 5 ELISAs done on 143 canine fecal specimens (100 diarrheic and 43 nondiarrheic dogs) and on 29 C. difficile isolates. The results of each ELISA were compared with the cytotoxin B tissue culture assay (CTA). Clostridium difficile was isolated from 23% of the fecal specimens. Eighteen of the 143 fecal specimens were toxin positive (15 diarrheic and 3 nondiarrheic dogs). On the basis of multiplex polymerase chain reaction (PCR) analysis for toxin-A and -B genes, 72% of the isolates were toxigenic. The carriage rate of toxigenic isolates in diarrheic dogs was higher than that in the nondiarrheic dogs; however, these differences were not statistically significant. A good correlation was found between CTA, PCR, and culture results. The ELISAs done on fecal specimens collected from diarrheic dogs had low sensitivity (7-33%). In contrast, ELISA for toxin A or B, or both, performed on toxigenic isolates had high sensitivity (93%). These results suggest that commercially available human ELISAs are inadequate for the diagnosis of canine C. difficile-associated diarrhea when tested on fecal specimens. In contrast, the Premier ToxinA/B and Techlab ToxinA/B ELISAs may be useful for the diagnosis of canine CDAD when used on toxigenic isolates.
Harris, A N; Beatty, S S; Estrada, A H; Winter, B; Bohannon, M; Sosa, I; Hanscom, J; Mainville, C A; Gallagher, A E
2017-07-01
N-terminal prohormone of brain natriuretic peptide (NT-proBNP) concentrations may be increased in cats with various cardiac disorders. The point-of-care (POC) ELISA assay uses the same biologic reagents as the quantitative NT-proBNP ELISA. Previous studies have evaluated the sensitivity and specificity of the POC ELISA in cats with cardiac disease. To prospectively evaluate the diagnostic utility of the POC ELISA in a select population of cats. Thirty-eight client-owned cats presented to the University of Florida Cardiology Service for cardiac evaluation. Fifteen apparently healthy cats recruited as part of another study. Physical examination and echocardiography were performed in all cats. The POC ELISA was assessed visually as either positive or negative by a reader blinded to the echocardiographic findings, and results were analyzed relative to quantitative assay results. Twenty-six cats were diagnosed with underlying cardiac disease, and 27 cats were considered free of cardiac disease. Cats with cardiac disease included: 21 with hypertrophic cardiomyopathy, 2 with unclassified cardiomyopathy, 2 with restrictive cardiomyopathy, and 1 with 3rd degree atrioventricular (AV) block. The POC ELISA differentiated cats with cardiac disease with a sensitivity of 65.4% and specificity of 100%. The POC NT-proBNP ELISA performed moderately well in a selected population of cats. A negative test result cannot exclude the presence of underlying cardiac disease, and a positive test result indicates that cardiac disease likely is present, but further diagnostic investigation would be indicated for a definitive diagnosis. Copyright © 2017 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.
Wang, Linchuan; Tian, Xu-Dong; Yu, Yan; Chen, Wei
2018-04-01
The IGRA-ELISA and T-SPOT.TB are widely used in China. The aim of the study was to evaluate the performance of the two assays in diagnosis Mycobacterium tuberculosis infection. Of the 3727 patients in the study, 204 underwent testing using both the T-SPOT.TB and IGRA-ELISA, 1794 were tested using the T-SPOT.TB only, and 1729 were tested using the IGRA-ELISA only. The positive rate and consistency of the two assays were analyzed, and their sensitivity and specificity for diagnosing active tuberculosis were compared. There were no significant differences in the positive rate between the T-SPOT.TB test (25.8%) and IGRA-ELISA (28.6%), p = .065. The two assays were highly consistent, with a kappa value of 0.852 (p < .0001) and a total coincidence rate of 92.7%. For the diagnosis of active tuberculosis, the sensitivity and specificity values of the T-SPOT.TB test were 82.9% (107/129) and 78.6% (1309/1665), respectively, and those of IGRA-ELISA were 81.7% (94/115) and 75.2% (1214/1614), respectively. There were no significant differences in sensitivity (p > .05), but the specificity of the T-SPOT.TB test was slightly higher than that of IGRA-ELISA (p = .023). Both in terms of diagnosing M. tuberculosis infection and ruling out active tuberculosis, the performance of the IGRA-ELISA-a simple, almost labor-free assay that allows simultaneous processing of a very large number of samples-was well-matched with that of T-SPOT.TB test. However, IGRAs cannot be used as the only test to diagnose active tuberculosis. Copyright © 2018 Elsevier B.V. All rights reserved.
van den Brom, R; van Engelen, E; Luttikholt, S; Moll, L; van Maanen, K; Vellema, P
2012-03-24
In 2007, a human Q fever epidemic started, mainly in the south eastern part of The Netherlands with a suspected indirect relation to dairy goats, and, to a lesser degree, to dairy sheep. This article describes the Q fever prevalences in Dutch dairy goat and dairy sheep bulk tank milk (BTM) samples, using a real-time (RT) PCR and ELISA. Results of BTM PCR and ELISA were compared with the serological status of individual animals, and correlations with a history of Q fever abortion were determined. When compared with ELISA results, the optimal cut-off value for the RT-PCR was 100 bacteria/ml. In 2008, there were 392 farms with more than 200 dairy goats, of which 292 submitted a BTM sample. Of these samples, 96 (32.9 per cent) were PCR positive and 87 (29.8 per cent) were ELISA positive. All farms with a history of Q fever abortion (n=17) were ELISA positive, 16 out of 17 were also PCR positive. BTM PCR or ELISA positive farms had significantly higher within-herd seroprevalences than BTM negative farms. In the south eastern provinces, the area where the human Q fever outbreak started in 2007, a significantly larger proportion of the BTM samples was PCR and ELISA positive compared to the rest of The Netherlands. None of the BTM samples from dairy sheep farms (n=16) were PCR positive but three of these farms were ELISA positive. The higher percentage of BTM positive farms in the area where the human Q fever outbreak started, supports the suspected relation between human cases and infected dairy goat farms.
Kittelberger, R; O'Keefe, J S; Meynell, R; Sewell, M; Rosati, S; Lambert, M; Dufour, P; Pépin, M
2006-02-01
To determine the diagnostic capability of a newly developed Western blot (WB) assay for the detection of serum antibodies against Mycoplasma agalactiae compared with conventional serological tests, and to identify the best test for routine diagnostic use. The serological test methods used were: two commercial indirect enzyme-linked immunosorbent assays (ELISA), viz ELISA-1, using a bacterial antigen preparation, and ELISA-2, using a recombinant protein (lipoprotein p48) antigen; the complement fixation test (CFT); and a newly developed WB assay, the latter both using a bacterial antigen preparation. Thirty sera from goats infected with M. agalactiae and 97 sera from non-infected sheep were tested using all four methods. Staining patterns in the WB were quite variable. An immuno-dominant band of 41 kDa was detected in 63% of sera from infected animals. The same band also appeared, although mostly very weakly, in 10% of sera from non-infected animals. When suspicious or very weak reactors were omitted, the diagnostic sensitivity (DSE) and diagnostic specificity (DSP), respectively, for the four assays were: WB=56.7%, 97.9%; ELISA-1=76.7%, 99.0%; ELISA-2=56.7%, 100%; and CFT=40.0%, 94.8%. ELISA-1 performed best in this comparison. While the WB can be used, it did not have a technical advantage over the ELISA. The CFT should be discouraged as the primary screening method for contagious agalactia and should be replaced by ELISA-1. Results from this study confirm that serological test methods for contagious agalactia are useful for the detection of infected flocks but will not detect every individual infected animal.
Single-tier testing with the C6 peptide ELISA kit compared with two-tier testing for Lyme disease.
Wormser, Gary P; Schriefer, Martin; Aguero-Rosenfeld, Maria E; Levin, Andrew; Steere, Allen C; Nadelman, Robert B; Nowakowski, John; Marques, Adriana; Johnson, Barbara J B; Dumler, J Stephen
2013-01-01
For the diagnosis of Lyme disease, the 2-tier serologic testing protocol for Lyme disease has a number of shortcomings including low sensitivity in early disease; increased cost, time, and labor; and subjectivity in the interpretation of immunoblots. In this study, the diagnostic accuracy of a single-tier commercial C6 ELISA kit was compared with 2-tier testing. The results showed that the C6 ELISA was significantly more sensitive than 2-tier testing with sensitivities of 66.5% (95% confidence interval [CI] 61.7-71.1) and 35.2% (95% CI 30.6-40.1), respectively (P < 0.001) in 403 sera from patients with erythema migrans. The C6 ELISA had sensitivity statistically comparable to 2-tier testing in sera from Lyme disease patients with early neurologic manifestations (88.6% versus 77.3%, P = 0.13) or arthritis (98.3% versus 95.6%, P = 0.38). The specificities of C6 ELISA and 2-tier testing in over 2200 blood donors, patients with other conditions, and Lyme disease vaccine recipients were found to be 98.9% and 99.5%, respectively (P < 0.05, 95% CI surrounding the 0.6 percentage point difference of 0.04 to 1.15). In conclusion, using a reference standard of 2-tier testing, the C6 ELISA as a single-step serodiagnostic test provided increased sensitivity in early Lyme disease with comparable sensitivity in later manifestations of Lyme disease. The C6 ELISA had slightly decreased specificity. Future studies should evaluate the performance of the C6 ELISA compared with 2-tier testing in routine clinical practice. Copyright © 2013 Elsevier Inc. All rights reserved.
Pagnon, Anke; Piras, Fabienne; Gimenez-Fourage, Sophie; Dubayle, Joseline; Arnaud-Barbe, Nadège; Hessler, Catherine; Caillet, Catherine
2017-11-01
In clinical trials of cytomegalovirus (CMV) glycoprotein B (gB) vaccines, CMV infection is detected by first depleting serum of anti-gB antibodies and then measuring anti-CMV antibodies with a commercially available enzyme-linked immunosorbent assay (ELISA) kit, with confirmation of positive findings by immunoblot. Identification of CMV immunoantigens for the development of an ELISA that detects specifically CMV infection in clinical samples from individuals immunized with gB vaccines. Sensitivity and specificity of ELISAs using antigenic regions of CMV proteins UL83/pp65, UL99/pp28, UL44/pp52, UL80a/pp38, UL57, and UL32/pp150 were measured. An IgG ELISA using a UL32/pp150 [862-1048] capture peptide was the most specific (93.7%) and sensitive (96.4%) for detecting CMV-specific antibodies in sera. The ELISA successfully detected CMV-specific antibodies in 22 of 22 sera of subjects who had been vaccinated with a gB vaccine but who had later been infected with CMV. The ELISA was linear over a wide range of CMV concentrations (57-16,814 ELISA units/mL) and was reproducible as indicated by a 5% intra-day and 7% inter-day coefficients of variation. The signal was specifically competed by UL32/pp150 [862-1048] peptide but not by CMV-gB or herpes simplex virus 2 glycoprotein D. Lipid and hemoglobin matrix did not interfere with the assay. The UL32/pp150 [862-1048] IgG ELISA can be used for the sensitive and specific detection of CMV infection in gB-vaccinated individuals. Copyright © 2017 Elsevier B.V. All rights reserved.
Wang, Lei; Wang, Xiaoxia; Li, Ying; Cheng, Zeneng
2016-01-01
Etanercept is the first tumor necrosis factor inhibitor to be approved for rheumatic disease treatment. Its in vivo concentration is usually detected with commercial enzyme-linked immunosorbent assay (ELISA) kits; specifically, previous researchers have mostly used double-antibody sandwich ELISA technology. Double-antibody sandwich ELISA is employed to detect the total etanercept rather than biologically active etanercept, which is more relevant in terms of therapeutic drug monitoring. In this work, a sensitive ELISA that employed its antigen TNF-α to capture biologically active etanercept for concentration detection was established and validated for etanercept pharmacokinetic (PK) study in patients with ankylosing spondylitis (AS). The proposed assay was demonstrated to be precise and accurate over the linear range of 12.5-400pg/mL. The intra- and inter-assay relative standard deviation ranged from 3.9 to 12.2% and 6.2 to 11.1%, respectively, and recovery varied between 90.1 and 99.7%, confirming the assay's reliability. The effectiveness and accuracy of the assay was also validated according to quality samples containing etanercept with different TNF-α concentrations, and with plasma samples from patients with AS. To complete the study, both the proposed assay and double-antibody sandwich ELISA were applied to the PK study of etanercept in patients and compared. The multiple-dose results of both analytical methods were consistent, while the drug exposure of the first dose as-detected by the proposed assay was lower than that detected by double-antibody sandwich ELISA. In conclusion, the proposed ELISA was shown to provide more accurate concentration data for therapeutic drug monitoring in comparison to commercial ELISA kits. Copyright © 2015 Elsevier B.V. All rights reserved.
Abdelwahab, Mohamed; Loa, Chien Chang; Wu, Ching Ching; Lin, Tsang Long
2015-06-01
Nucleocapsid (N) protein gene of turkey coronavirus (TCoV) was expressed in a prokaryotic system and used to develop an enzyme-linked immunosorbent assay (ELISA) for detection of antibody to TCoV. Anti-TCoV hyperimmune turkey serum and normal turkey serum were used as positive or negative controls for optimization of the ELISA. Goat anti-turkey IgG (H+L) conjugated with horseradish peroxidase was used as detector antibody. Three hundred and twenty two turkey sera from the field were used to evaluate the performance of ELISA and determine the cut-off point of ELISA. The established ELISA was also examined with serum samples obtained from turkeys experimentally infected with TCoV. Those serum samples were collected at various time intervals from 1 to 63 days post-infection. The optimum conditions for differentiation between anti-TCoV hyperimmune serum and normal turkey serum were recombinant TCoV N protein concentration at 20 μg/ml, serum dilution at 1:800, and conjugate dilution at 1:10,000. Of the 322 sera from the field, 101 were positive for TCoV by immunofluorescent antibody assay (IFA). The sensitivity and specificity of the ELISA relative to IFA test were 86.0% and 96.8%, respectively, using the optimum cut-off point of 0.2 as determined by logistic regression method. Reactivity of anti-rotavirus, anti-reovirus, anti-adenovirus, or anti-enterovirus antibodies with the recombinant N protein coated on the ELISA plates was not detected. These results indicated that the established antibody-capture ELISA in conjunction with recombinant TCoV N protein as the coating protein can be utilized for detection of antibodies to TCoV in turkey flocks. Copyright © 2015 Elsevier B.V. All rights reserved.
Low-cost and easy-to-use "on-chip ELISA" for developing health-promoting foods.
Hoshino, Fumihiko; Watanabe, Osamu; Wu, Xiaohong; Takimoto, Yosuke; Osawa, Toshihiko
2014-01-01
We have determined that a biological molecule can be physically immobilized on a polymer containing an azobenzene (azopolymer) using irradiating light. We immobilized antibodies and antigens on the surface of an azopolymer coated glass slide (antibody array) to establish "on-chip ELISAs". The assays used the flat-surface of a glass slide and could be applied to both sandwich and competitive ELISAs. The sensitivity and accuracy of the on-chip ELISA were similar to a conventional ELISA using a polystyrene plate. Using the assay system, we proved that representative oxidative-biomarkers could be simultaneously measured from uL of urine. That should realize low-cost study on animal or human, and accelerate development of health-promoting foods. So, this new concept antibody array has promising applications in proteomic studies, and could be used to examine biomarkers to investigate health-promoting food.
Citrullinated Chemokines in Rheumatoid Arthritis
2016-12-01
immunosorbent assay ( ELISA ) in RA and normal (NL) sera and in RA, osteoarthritis (OA), and other inflammatory rheumatic disease (OD) synovial fluids (SFs... ELISA ) Epithelial Neutrophil Chemoattractant Peptide-78 (ENA-78/CXCL5) Monocyte Chemoattractant Protein-1 (MCP-1/CCL2) Macrophage Inflammatory...Citrullinated chemokines are highly expressed in RA sera and SFs. Citrullinated chemokines were measured using an ELISA in which chemokines were captured on
Effects of Early Altitude Exposure Following Traumatic Injury and Hemorrhagic Shock
2017-06-27
chemokines by multiplex enzyme-linked immunosorbent assay ( ELISA ) (Quansys, Logan, UT), including the following: interleukin 1 alpha and beta (IL...Tissue Cytokine Profiles Fourteen cytokines and chemokines were analyzed from serum and intestinal tissues via multiplex ELISA . There were no...2017-3567, 25 Jul 2017. LIST OF ABBREVIATIONS AND ACRONYMS AE aeromedical evacuation BCA bicinchoninic acid ELISA enzyme-linked immunosorbent
Code of Federal Regulations, 2010 CFR
2010-01-01
... enzyme-linked immunosorbent assay (ELISA) or a gpI Particle Concentration Fluorescence Immunoassay (PCFIA... negative; (iv) The date of the gpI ELISA or the gpI PCFIA approved differential pseudorabies test; and (v) The name of the laboratory that conducted the gpI ELISA or the gpI PCFIA approved differential...
Code of Federal Regulations, 2011 CFR
2011-01-01
... enzyme-linked immunosorbent assay (ELISA) or a gpI Particle Concentration Fluorescence Immunoassay (PCFIA... negative; (iv) The date of the gpI ELISA or the gpI PCFIA approved differential pseudorabies test; and (v) The name of the laboratory that conducted the gpI ELISA or the gpI PCFIA approved differential...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-16
...-Mouth Disease 3ABC ELISA Diagnostic Kit AGENCY: Science and Technology Directorate, Plum Island Animal... Center (PIADC), is seeking industry collaborators to aid DHS S&T in developing an ELISA diagnostic test... and Mouth Disease virus (FMDV) non-structural proteins (NSP): 3A, 3B, or 3C. This new FMDV 3ABC ELISA...
Code of Federal Regulations, 2012 CFR
2012-01-01
... enzyme-linked immunosorbent assay (ELISA) or a gpI Particle Concentration Fluorescence Immunoassay (PCFIA... negative; (iv) The date of the gpI ELISA or the gpI PCFIA approved differential pseudorabies test; and (v) The name of the laboratory that conducted the gpI ELISA or the gpI PCFIA approved differential...
Code of Federal Regulations, 2014 CFR
2014-01-01
... enzyme-linked immunosorbent assay (ELISA) or a gpI Particle Concentration Fluorescence Immunoassay (PCFIA... negative; (iv) The date of the gpI ELISA or the gpI PCFIA approved differential pseudorabies test; and (v) The name of the laboratory that conducted the gpI ELISA or the gpI PCFIA approved differential...
Code of Federal Regulations, 2013 CFR
2013-01-01
... enzyme-linked immunosorbent assay (ELISA) or a gpI Particle Concentration Fluorescence Immunoassay (PCFIA... negative; (iv) The date of the gpI ELISA or the gpI PCFIA approved differential pseudorabies test; and (v) The name of the laboratory that conducted the gpI ELISA or the gpI PCFIA approved differential...
Evaluation of Commercially Available Anti–Dengue Virus Immunoglobulin M Tests
Hunsperger, Elizabeth A.; Yoksan, Sutee; Buchy, Philippe; Nguyen, Vinh Chau; Sekaran, Shamala D.; Enria, Delia A.; Pelegrino, Jose L.; Vázquez, Susana; Artsob, Harvey; Drebot, Michael; Gubler, Duane J.; Halstead, Scott B.; Guzmán, María G.; Margolis, Harold S.; Nathanson, Carl-Michael; Lic, Nidia R. Rizzo; Bessoff, Kovi E.; Kliks, Srisakul
2009-01-01
Anti–dengue virus immunoglobulin M kits were evaluated. Test sensitivities were 21%–99% and specificities were 77%–98% compared with reference ELISAs. False-positive results were found for patients with malaria or past dengue infections. Three ELISAs showing strong agreement with reference ELISAs will be included in the World Health Organization Bulk Procurement Scheme. PMID:19239758
[Determination of antiphospholipid antibodies in serum using ELISA].
Fialová, L; Mikulíková, L; Malbohan, I; Průcha, M; Palecková, A; Cerný, V
1994-05-01
The authors compare two ELISA methods for the assessment of antiphospholipid antibodies, classes IgG and IgM, in serum: ELISA Pin Plate System ALPHA DIALAB Co. and the ELISA method developed in the Research Institute of Rheumatic Diseases. Both methods use cardiolipin as antigen. In the Pin Plate test the immunochemical reaction antigen/antibody does not take place at the surface of the pits of the microtitration plates but on the tip of the next plate. The results of examinations of antiphospholipid antibodies obtained by the tested methods are comparable, the Pin Plate test is quicker and more sensitive, but its price limits routine use.
Zaripov, M M; Afanasieva, G V; Glukhova, X A; Trizna, Y A; Glukhov, A S; Beletsky, I P; Prusakova, O V
2015-01-01
A simple and fast method for obtaining biotin-labeled monoclonal antibodies was developed usingcontent of hybridoma culture supernatant sufficient to select antibody pairs in sandwich ELISA. The method consists in chemical biotinylation of antigen-bound antibodies in a well of ELISA plate. Using as an example target Vaccinia virus A27L protein it was shown that the yield of biotinylated reactant is enough to set comprehensive sandwich ELISA for a moderate size panel of up to 25 monoclonal antibodies with an aim to determine candidate pairs. The technique is a cheap and effective solution since it avoids obtaining preparative amounts of antibodies.
Chen, Xiaowei; Song, Cailing; Liu, Yun; Qu, Liandong; Liu, Dafei; Zhang, Yun; Liu, Ming
2016-02-01
For detection of Aleutian mink disease virus (AMDV) antibodies, an enzyme-linked immunosorbent assay (ELISA) was developed using the recombinant VP2332-452 protein as an antigen. Counterimmunoelectrophoresis (CIEP) was used as a reference test to compare the results of the ELISA and Western blotting (WB); the specificity and sensitivity of the VP2332-452 ELISA were 97.9% and 97.3%, respectively, which were higher than those of WB. Therefore, this VP2332-452 ELISA may be a preferable method for detecting antibodies against AMDV. Copyright © 2016, American Society for Microbiology. All Rights Reserved.
Sakata, H; Hishiyama, M; Sugiura, A
1984-01-01
Mumps-specific antibody levels before and after vaccination with live mumps vaccines were determined by enzyme-linked immunosorbent assay (ELISA) and neutralization tests. A correlation was found between neutralization titers and optical density in ELISA. However, postvaccination sera from some vaccinees who failed to seroconvert by neutralization contained significant levels of mumps-specific antibody detectable by ELISA. In some of these serum specimens, the antibody directed to the F polypeptide of mumps virus was predominant. Most sera positive in ELISA neutralized mumps virus upon the addition of fresh guinea pig serum to the virus-serum mixture. Images PMID:6361060
[Development of ELISA-kit of quantitative analysis for Zearalenone].
Wang, Yu-ping; Ji, Rong; Jiang, Tao; Kang, Wei-jun
2006-03-01
To develope a rapid, sensitive, quantitative ELISA-kit for Zearalenone and determine zearalenone in cereals. On the base of monoclonal antibodies against ZEN, apply indirect ELISA to study the performance parameter of the kit. The limited concentration of detection of the ELISA-kit was 1ng/ml, linear range was 1-200 ng/ml, the linear equation was Y = 0.99 - 0.40 x (R2 = 0.99). The inhibition concentration of 50% against ZEN was 16.3 ng/ml. The average recovery rate of spiked corn and wheat was 96.5% and 95.5%, respectively, the coefficient of variant was 13.2% and 10.9%, respectively. The kit can be stored at 4 degrees C over 6 months. The cross reaction rate with the other mycotoxins was less than 1%, and coefficient of variant within-laboratory and between-laboratory was less than 15% and less than 20%, respectively. Detecting the VICAM sample with ELISA method and HPLC method, the results were within the range of the sample, and there was no statistic difference between the two methods. This ELISA-kit was quick, sensitive, stable and specific and can be used to determine ZEN in cereals.
Rapid screening of toxigenic vibrio cholerae O1 strains from south Iran by PCR-ELISA.
Mousavi, Seyed Latif; Nazarian, Shahram; Amani, Jafar; Rahgerdi, Ahmad Karimi
2008-01-01
The ability to sensitively detect Vibrio cholera with PCR-ELISA method represents a considerable advancement over alternative more time-consuming methods for detection of this pathogen. The aim of this research is to evaluate the suitability of a PCR-enzyme-linked immunosorbent assay for sensitive and rapid detection of V. cholera O1. The 398-bp sequence of a gene that codes for the cholera toxin B subunit was amplified by PCR. The digoxigenin-labeled amplified products were coated on microplates and detected by ELISA. The PCR product was also hybridized with biotin labelled probe and detected by ELISA using streptavidin. The specificity of the PCR was determined using 10 bacterial strains and 50 samples from south Iran. The detection limit was 0.5 pg of the genomic DNA and five bacterial cells. Adaptation of PCR into PCR-ELISA assay format facilitates specific and sensitive detection and diagnosis of human cholera disease. We conclude that this PCR-ELISA is a diagnostic method that specifically detects toxin genes in V. cholera O1 strains. It is more rapid and less cumbersome than other diagnostic methods for detection of toxicity in these strains.
2017-01-01
Background Malaria control efforts are limited in rural areas. A low-cost system to monitor response without the use of electricity is needed. Plasmodium aldolase is a malaria biomarker measured using enzyme linked immunosorbent assay (ELISA) techniques. A three-part system using ELISA was developed consisting of a microfluidic chip, hand crank centrifuge, and a smartphone. Methods A circular microfluidic chip was fabricated using clear acrylic and a CO2 laser. A series of passive valves released reagents at precise times based upon centrifugal force. Color change was measured via smartphone camera using an application programmed in Java. The microchip was compared to a standard 96-well sandwich ELISA. Results Results from standard ELISA were compared to microchip at varying concentrations (1–10 ng/mL). Over 15 different microfluidic patterns were tested, and a final prototype of the chip was created. The prototype microchip was compared to standard sandwich ELISA (n = 20) using samples of recombinant aldolase. Color readings of standard ELISA and microfluidic microchip showed similar results. Conclusion A low-cost microfluidic system could detect and follow therapeutic outcomes in rural areas and identify resistant strains. PMID:29057138
Caciagli, P; Verderio, A
2003-06-30
Several aspects of enzyme-linked immunosorbent assay (ELISA) procedures and data analysis have been examined in an attempt to find a rapid and reliable method for discriminating between 'positive' and 'negative' results when testing a large number of samples. A layout of ELISA plates was designed to reduce uncontrolled variation and to optimize the number of negative and positive controls. A transformation using the fourth root (A(1/4)) of the optical density readings corrected for the blank (A) stabilized the variance of most ELISA data examined. Transformed A values were used to calculate the true limits, at a set protection level, for false positive (C) and false negative (D). Methods are discussed to reduce the number of undifferentiated samples, i.e. the samples with response falling between C and D. The whole procedure was set up for use with an electronic spreadsheet. With the addition of few instructions of the type 'if em leader then em leader else' in the spreadsheet, the ELISA results were obtained in the simple trichotomous form 'negative/undefined/positive'. This allowed rapid analysis of more than 1100 maize samples testing for the presence of seven aphid-borne viruses-in fact almost 8000 ELISA samples.
NGUYEN, Thu-Thuy; MOTSIRI, Mono Sophie; TAIOE, Moeti Oriel; MTSHALI, Moses Sibusiso; GOTO, Yasuyuki; KAWAZU, Shin-Ichiro; THEKISOE, Oriel Matlhahane Molifi; INOUE, Noboru
2014-01-01
A total of 231 serum samples were collected from sheep (n=9), goats (n=99) and cattle (n=123) in northeastern KwaZulu-Natal, South Africa. Trypanosome infection was detected using Trypanosoma brucei brucei crude antigen (TbbCA) and T. congolense crude antigen (TcoCA) ELISA assays. Recombinant antigen (T. evansi GM6 which consisted of 4 repeat domains, TeGM6-4r) ELISA and immunochromatographic test (ICT) were also used. Crude antigen ELISA, TeGM6-4r-ELISA and ICT detected 27.3%, 29% and 19.9% of trypanosome seropositive samples, respectively. Trypanosome infection prevalence in cattle and goats was 35.8–46.3% and 0–9.1%, respectively. Out of 9 sheep serum samples, 2–4 sera (22.2–44.4%) were positive. The detection performance of crude and recombinant antigen ELISAs was relatively similar (K=0.6–0.7); both are recommended for reference diagnosis and large scale epidemiological surveys. There is potential application for ICT in on-site diagnosis, but its sensitivity should be improved. PMID:25342634
Competitive and noncompetitive phage immunoassays for the determination of benzothiostrobin.
Hua, Xiude; Zhou, Liangliang; Feng, Lu; Ding, Yuan; Shi, Haiyan; Wang, Limin; Gee, Shirley J; Hammock, Bruce D; Wang, Minghua
2015-08-26
Twenty-three phage-displayed peptides that specifically bind to an anti-benzothiostrobin monoclonal antibody (mAb) in the absence or presence of benzothiostrobin were isolated from a cyclic 8-residue peptide phage library. Competitive and noncompetitive phage enzyme linked immunosorbent assays (ELISAs) for benzothiostrobin were developed by using a clone C3-3 specific to the benzothiostrobin-free mAb and a clone N6-18 specific to the benzothiostrobin immunocomplex, respectively. Under the optimal conditions, the half maximal inhibition concentration (IC50) of the competitive phage ELISA and the concentration of analyte producing 50% saturation of the signal (SC50) of the noncompetitive phage ELISA for benzothiostrobin were 0.94 and 2.27 ng mL(-1), respectively. The noncompetitive phage ELISA showed higher selectivity compared to the competitive. Recoveries of the competitive and the noncompetitive phage ELISAs for benzothiostrobin in cucumber, tomato, pear and rice samples were 67.6-119.6% and 70.4-125.0%, respectively. The amounts of benzothiostrobin in the containing incurred residues samples detected by the two types of phage ELISAs were significantly correlated with that detected by high-performance liquid chromatography (HPLC). Copyright © 2015 Elsevier B.V. All rights reserved.
Martínez-Torrecuadrada, Jorge L.; Lázaro, Beatriz; Rodriguez, José F.; Casal, J. Ignacio
2000-01-01
The routine technique for detecting antibodies specific to infectious bursal disease virus (IBDV) is a serological evaluation by enzyme-linked immunosorbent assay (ELISA) with preparations of whole virions as the antigens. To avoid using complete virus in the standard technique, we have developed two new antigens through the expression of the VPX and VP3 genes in insect cells. VPX and especially VP3 were expressed at high levels in insect cells and simple to purify. The immunogenicity of both proteins was similar to that of the native virus. VPX was able to elicit neutralizing antibodies but VP3 was not. Purified VPX and VP3 were tested in an indirect ELISA with more than 300 chicken sera. There was an excellent correlation between the results of the ELISA using VPX and those of the two commercial kits. VP3 did not perform as well as VPX, and the linear correlation was significantly lower. A comparison with the standard reference technique, seroneutralization, showed that the indirect ELISA was more sensitive. Therefore, VPX-based ELISA is a good alternative to conventional ELISAs that use whole virions. PMID:10882666
Martínez-Torrecuadrada, J L; Lázaro, B; Rodriguez, J F; Casal, J I
2000-07-01
The routine technique for detecting antibodies specific to infectious bursal disease virus (IBDV) is a serological evaluation by enzyme-linked immunosorbent assay (ELISA) with preparations of whole virions as the antigens. To avoid using complete virus in the standard technique, we have developed two new antigens through the expression of the VPX and VP3 genes in insect cells. VPX and especially VP3 were expressed at high levels in insect cells and simple to purify. The immunogenicity of both proteins was similar to that of the native virus. VPX was able to elicit neutralizing antibodies but VP3 was not. Purified VPX and VP3 were tested in an indirect ELISA with more than 300 chicken sera. There was an excellent correlation between the results of the ELISA using VPX and those of the two commercial kits. VP3 did not perform as well as VPX, and the linear correlation was significantly lower. A comparison with the standard reference technique, seroneutralization, showed that the indirect ELISA was more sensitive. Therefore, VPX-based ELISA is a good alternative to conventional ELISAs that use whole virions.
Praet, Nicolas; Verweij, Jaco J; Mwape, Kabemba E; Phiri, Isaac K; Muma, John B; Zulu, Gideon; van Lieshout, Lisette; Rodriguez-Hidalgo, Richar; Benitez-Ortiz, Washington; Dorny, Pierre; Gabriël, Sarah
2013-05-01
To estimate and compare the performances of coprology, copro-Ag ELISA and real-time polymerase chain reaction assay (copro-PCR) for detection of Taenia solium tapeworm carriers. The three diagnostic tests were applied on 817 stool samples collected in two Zambian communities where taeniasis is endemic. A Bayesian approach was used to allow estimation of the test characteristics. Two (0.2%; 95% Confidence Interval (CI): 0-0.8), 67 (8.2%; 95% CI: 6.4-10.3) and 10 (1.2%; 95% CI: 0.5-2.2) samples were positive using coprology, copro-Ag ELISA and copro-PCR, respectively. Specificities of 99.9%, 92.0% and 99.0% were determined for coprology, copro-Ag ELISA and copro-PCR, respectively. Sensitivities of 52.5%, 84.5% and 82.7% were determined for coprology, copro-Ag ELISA and copro-PCR, respectively. We urge for additional studies exploring possible cross-reactions of the copro-Ag ELISA and for the use of more sensitive tests, such as copro-PCR, for the detection of tapeworm carriers, which is a key factor in controlling the parasite in endemic areas. © 2013 Blackwell Publishing Ltd.
Li, Cui; Zhang, Yaoyao; Eremin, Sergei A; Yakup, Omar; Yao, Gang; Zhang, Xiaoying
2017-07-15
Our aim in this study is to show that IgY antibody based immunoassays could be used to detect antibiotic residues in animal-derived food. Briefly, full antigens of gentamicin (Gent) and kanamycin (Kana) were used to immunize the laying chickens to prepare IgY antibodies. Then, these antibodies were evaluated by FPIA and ic-ELISA to detect Gent/Kana in animal-derived samples. The IC 50 of FPIA and ic-ELISA based anti-Gent IgY were 7.70±0.6μg/mL and 0.32±0.06μg/mL, respectively. The IC 50 of FPIA and ic-ELISA based anti-Kana IgY were 7.97±0.9μg/mL and 0.15±0.01μg/mL. The limits of detection (LOD, IC 10 ) for FPIA based anti-Gent/Kana IgY were 0.17 and 0.007μg/mL, respectively. The LOD for ic-ELISA were both 0.001μg/mL. These results indicated that the ic-ELISA might more suitable for antibiotic residues detection than FPIA. Copyright © 2017 Elsevier Ltd. All rights reserved.
Short communication: ELISA system for screening of bovine mastitis caused by Prototheca zopfii.
Kano, Rui; Sato, Ayano; Sobukawa, Hideto; Sato, Yuko; Ito, Takaaki; Suzuki, Kazuyuki; Hasegawa, Atsuhiko; Kamata, Hiroshi
2016-08-01
Prototheca zopfii is an achlorophyllic alga that causes bovine mastitis, resulting in a reduction in milk production and the secretion of thin, watery milk with white flakes. This study evaluated the use of an ELISA system for distinguishing cows with mastitis due to P. zopfii genotype 2 from healthy cows and cows with chronic candidal mastitis. We also investigated the transitional changes of specific antibody titers in healthy cows injected with inactivated P. zopfii genotype 2 cells. The ELISA system exhibited the highest sensitivity (94%) and specificity (100%) for chronic protothecal mastitis when the positive cutoff value was set at 43.4 ELISA units. Anti-protothecal IgG titers were positive in all cows after they were inoculated with inactivated P. zopfii genotype 2 cells. These results indicated that ELISA detection of anti-protothecal IgG in serum provided specificity and sensitivity sufficient for diagnosing protothecal mastitis. Thus, an ELISA system incorporating this specific antiserum is expected to be valuable for definitive field-based diagnosis of bovine mastitis due to P. zopfii genotype 2. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Ji, Mijung; Cho, Byungki; Cho, Young Shik; Park, Song-Yong; Cho, Sang-Nae
2014-01-01
Purpose Tuberculosis (TB) is a major infectious disease and is responsible for two million deaths annually. For the identification and quantitation of Mycobacterium tuberculosis (M. tuberculosis), a causative agent of TB, a sandwich enzyme-linked immunosorbent assay (ELISA) against the MPT64 protein of M. tuberculosis, an antigen marker of the M. tuberculosis complex, was developed. Materials and Methods The MPT64 protein was expressed, and anti-MPT64 monoclonal antibodies were prepared. A sandwich ELISA was established using recombinant MPT64 protein and anti-MPT64 monoclonal antibodies. The sandwich MPT64 ELISA was evaluated using reference and clinical mycobacterial strains. Results The sandwich MPT64 ELISA detected MPT64 protein from 2.1 ng/mL to 250 ng/mL (equivalent to 1.7×104 CFU/mL and 2.0×106 CFU/mL). All 389 clinical M. tuberculosis isolates tested positive in the sandwich MPT64 ELISA (sensitivity, 100%), and the assay showed no cross reactivity to any tested nontuberculous mycobacterial strain (specificity, 100%). Conclusion The sandwich MPT64 ELISA is a highly sensitive and quantitative test for MPT64 protein, which can identify M. tuberculosis. PMID:24719143
Nominal effective immunoreaction volume of magnetic beads at single bead level.
Wang, Rui; Chen, Yuan; Fan, Kai; Ji, Feng; Wu, Jian; Yu, Yong-Hua
Immunomagnetic bead (IMB)-based enzyme-linked immunosorbent assay (ELISA) has been the tool frequently used for protein detection in research and clinical laboratories. For most ELISA reactions the recommended dosage of IMBs is usually according to their weight (mg) or mass fraction (w/v) instead of the bead number. Consequently, the processes occurring in the immediate vicinity of the IMBs have always been ignored by researchers and they cannot be revealed in detail during the ELISA reaction. In this paper, we established the relationship between number of IMBs and colorimetric results, and further proposed a new concept of "nominal effective immunoreaction volume (NEIV)" to characterize a single IMB during ELISA reaction. Results showed that the NEIV of a single IMB has a constant value, which is unrelated to the amount of beads and the concentration of antigen. Optimal results of the colorimetric ELISA are achieved when the incubation volume meets each IMB's NEIV and is no longer enhanced by increasing the incubation volume. Thus, the reliable and relatively precise number of IMBs for ELISA detection during practical application could be determined. Most importantly, a study using IMB's NEIV would lay the foundation for a kinetics analysis of IMBs and antigens for future study.
Multi-analyte validation in heterogeneous solution by ELISA.
Lakshmipriya, Thangavel; Gopinath, Subash C B; Hashim, Uda; Murugaiyah, Vikneswaran
2017-12-01
Enzyme Linked Immunosorbent Assay (ELISA) is a standard assay that has been used widely to validate the presence of analyte in the solution. With the advancement of ELISA, different strategies have shown and became a suitable immunoassay for a wide range of analytes. Herein, we attempted to provide additional evidence with ELISA, to show its suitability for multi-analyte detection. To demonstrate, three clinically relevant targets have been chosen, which include 16kDa protein from Mycobacterium tuberculosis, human blood clotting Factor IXa and a tumour marker Squamous Cell Carcinoma antigen. Indeed, we adapted the routine steps from the conventional ELISA to validate the occurrence of analytes both in homogeneous and heterogeneous solutions. With the homogeneous and heterogeneous solutions, we could attain the sensitivity of 2, 8 and 1nM for the targets 16kDa protein, FIXa and SSC antigen, respectively. Further, the specific multi-analyte validations were evidenced with the similar sensitivities in the presence of human serum. ELISA assay in this study has proven its applicability for the genuine multiple target validation in the heterogeneous solution, can be followed for other target validations. Copyright © 2017 Elsevier B.V. All rights reserved.
A Monoclonal–Monoclonal Antibody Based Capture ELISA for Abrin
Tam, Christina C.; Cheng, Luisa W.; He, Xiaohua; Merrill, Paul; Hodge, David; Stanker, Larry H.
2017-01-01
Abrin, one of the most highly potent toxins in the world, is derived from the plant, Abrus precatorius. Because of its high toxicity, it poses potential bioterror risks. Therefore, a need exists for new reagents and technologies that would be able to rapidly detect abrin contamination as well as lead to new therapeutics. We report here a group of abrin-specific monoclonal antibodies (mAbs) that recognize abrin A-chain, intact A–B chain toxin, and agglutinin by Western blot. Additionally, these mAbs were evaluated for their ability to serve as capture antibodies for a sandwich (capture) ELISA. All possible capture–detector pairs were evaluated and the best antibody pair identified and optimized for a capture ELISA. The capture ELISA based on this capture–detector mAb pair had a limit of detection (L.O.D) of ≈1 ng/mL measured using three independent experiments. The assay did not reveal any false positives with extracts containing other potential ribosome-inactivating proteins (RIPs). Thus, this new capture ELISA uses mAbs for both capture and detection; has no cross-reactivity against other plant RIPs; and has a sensitivity comparable to other reported capture ELISAs using polyclonal antibodies as either capture or detector. PMID:29057799
Song, Ming-Fen; Li, Yun-Shan; Ootsuyama, Yuko; Kasai, Hiroshi; Kawai, Kazuaki; Ohta, Masanori; Eguchi, Yasumasa; Yamato, Hiroshi; Matsumoto, Yuki; Yoshida, Rie; Ogawa, Yasutaka
2009-07-01
Urinary 8-OH-dG is commonly analyzed as a marker of oxidative stress. For its analysis, ELISA and HPLC methods are generally used, although discrepancies in the data obtained by these methods have often been discussed. To clarify this problem, we fractionated human urine by reverse-phase HPLC and assayed each fraction by the ELISA method. In addition to the 8-OH-dG fraction, a positive reaction was observed in the first eluted fraction. The components in this fraction were examined by the ELISA. Urea was found to be the responsible component in this fraction. Urea is present in high concentrations in the urine of mice, rats, and humans, and its level is influenced by many factors. Therefore, certain improvements, such as a correction based on urea content or urease treatment, are required for the accurate analysis of urinary 8-OH-dG by the ELISA method. In addition, performance of the ELISA at 4 degrees C reduced the recognition of urea considerably and improved the 8-OH-dG analysis.
Preparation and Characteristic of Dextran-BSA Antibody and Establishment of its ELISA Immunoassay.
Xie, Zhen-ming; Yu, Lin; Fang, Li-sha
2015-01-01
The enzyme-linked immunosorbent assay (ELISA) is a potential tool for the determination of dextran. In this study, dextran neoglycoprotein antigens were prepared by Reductive Amination method, and were confirmed by SDS-PAGE and free amino detection. The impact factors such as different oxidation degree of dextran, the conjugate reaction time to BSA were investigated. The best preparation conditions were obtained (n(dextran)/n(oxidant) of NaIO4 = 1/120, the reaction time of 24 h), and the antigen with best combination with standard was obtained. The antigens interacted with standard antibody and were evaluated through ELISA. The immunogen was immunized with white rabbits to obtained antibody, respectively. A general and broad class-specific ELISA immunoassay was developed for dextran detection according to ELISA theory. The optimized conditions of assay used coating antigen at 10 μg/mL, reaction time of antibody and rabbit-anti-bovine IgG in 45 min, blocking reagents with 5% calf serum. The developed ELISA detection method with good linear and accuracy was put to use for quantitative analysis of dextran T40 in commercial sugarpractical for detection of dextran.
Ji, Mijung; Cho, Byungki; Cho, Young Shik; Park, Song-Yong; Cho, Sang-Nae; Jeon, Bo-Young; Yoon, Byoung-Su
2014-05-01
Tuberculosis (TB) is a major infectious disease and is responsible for two million deaths annually. For the identification and quantitation of Mycobacterium tuberculosis (M. tuberculosis), a causative agent of TB, a sandwich enzyme-linked immunosorbent assay (ELISA) against the MPT64 protein of M. tuberculosis, an antigen marker of the M. tuberculosis complex, was developed. The MPT64 protein was expressed, and anti-MPT64 monoclonal antibodies were prepared. A sandwich ELISA was established using recombinant MPT64 protein and anti-MPT64 monoclonal antibodies. The sandwich MPT64 ELISA was evaluated using reference and clinical mycobacterial strains. The sandwich MPT64 ELISA detected MPT64 protein from 2.1 ng/mL to 250 ng/mL (equivalent to 1.7×10⁴ CFU/mL and 2.0×10⁶ CFU/mL). All 389 clinical M. tuberculosis isolates tested positive in the sandwich MPT64 ELISA (sensitivity, 100%), and the assay showed no cross reactivity to any tested nontuberculous mycobacterial strain (specificity, 100%). The sandwich MPT64 ELISA is a highly sensitive and quantitative test for MPT64 protein, which can identify M. tuberculosis.
2013-01-01
Background Toxoplasmosis is one of the most common food borne zoonoses worldwide, and can be a serious life-threatening disease in the congenitally infected fetus and in immunosupressed patients. Among food animals, sheep along with goats and pigs possess the highest incidence of T. gondii cysts in meat, and play a major role as a source of human infection. Methods In this study, a new commercial ELISA kit (PrioCHECK® Toxoplasma Ab SR, Prionics Schlieren-Zurich, Switzerland) for the detection of anti-T. gondii antibodies in serum, plasma and meat juice of sheep, was evaluated by comparing it with the indirect fluorescent antibody test (IFAT), indirect haemagglutination test (IHA) and real-time PCR, on samples from experimentally inoculated and naturally exposed sheep. Results The commercial ELISA detected the infection status in 50% and 100% of sheep orally inoculated with 10,000 T. gondii oocysts (n = 6), from two or three weeks post infection (wpi), respectively, both on serum and plasma samples. Meat juice from all experimentally inoculated sheep collected at slaughter (12 wpi) showed positive ELISA values. In naturally exposed sheep (n = 396), the ELISA showed a very good agreement with IFAT (kappa = 0.91-1.0) and IHA (kappa = 0.96-1.0) performed on serum; and a positive correlation was observed between ELISA values and IFAT titers. By a Receiver Operating Characteristics (ROC) curve analysis, the commercial ELISA had relative sensitivities between 93.33% and 100%, and relative specificities between 96.87% and 100% respect to IFAT and IHA, depending on the considered cut-off value and animal groups tested. Furthermore, the ELISA correctly recognized all animals reacting positive in real-time PCR. The ELISA results on meat juice agreed with those on serum samples in all experimentally inoculated animals, and in 94 out of 96 (97.9%) naturally exposed sheep, when meat juice was tested at a 1:10 dilution. Conclusion The commercial ELISA kit evaluated in this study could represent a valuable tool to improve the surveillance and reporting system for T. gondii in sheep populations at the farm level or for diagnosis at the slaughterhouse, contributing to the control of this widespread zoonosis. PMID:23561035
Johnson, J C; Van Emon, J M
1996-01-01
An enzyme-linked immunosorbent assay (ELISA) for the quantitative determination of Aroclors 1242, 1248, 1254, and 1260 in soil and sediments was developed and its performance compared with that of gas chromatography (GC). The detection limits for Aroclors 1242 and 1248 in soil are 10.5 and 9 ng/g, respectively. The assay linear dynamic range is 50-1333 ng/g. Cross-reactivity of the assay with 37 structurally related potential cocontaminants in environmental soil samples was examined; none of the chlorinated anisoles, benzenes, or phenols exhibited >3% cross-reactivity, with <0.1% cross-reactivity being the norm. Soil spike recoveries of 107% and 104% were obtained for Aroclors 1242 and 1248, respectively, for a spike level of 5 mg/kg, with corresponding relative standard deviations of 14% and 17%. One hundred forty-eight environmental soil, sediment, and paper pulp samples, obtained from two EPA listed Superfund sites, were analyzed by ELISA and standard GC methods. Samples were extracted for ELISA analysis by shaking with methanol. Additional extractions of the same samples were performed either with supercritical carbon dioxide or by Soxhlet extraction with methanol. ELISA results for both the supercritical fluid and the Soxhlet extracts were in close agreement with the GC results, while the ELISA results for the methanol shake extracts were not. The data for the environmental samples demonstrated the capability of the ELISA to provide accurate results and reinforced the dependence of any detection method, including ELISA, on appropriate extraction procedures.
Kerkar, N; Ma, Y; Hussain, M; Muratori, L; Targett, C; Williams, R; Bianchi, F B; Mieli-Vergani, G; Vergani, D
1999-03-04
Liver Kidney Microsomal type 1 (LKM1) antibody, the diagnostic marker of autoimmune hepatitis type 2, is also found in a proportion of patients with hepatitis C virus infection (HCV). It is detected conventionally by the subjective immunofluorescence technique. Our aim was to establish a simple and objective enzyme-linked immunosorbent assay (ELISA) that measures antibodies to cytochrome P4502D6 (CYP2D6), the target of LKM1. An indirect ELISA using eukaryotically expressed CYP2D6 was designed. Absorbance values obtained against a reference microsomal preparation were subtracted from those obtained against a microsomal preparation over-expressing CYP2D6, thus removing the non-CYP2D6-specific reaction. Sera from 51 LKM1 positive patients (21 autoimmune hepatitis and 30 with HCV infection), 111 LKM1 negative patients with chronic liver disease (including 20 with HCV infection) and 43 healthy controls were tested. Of 51 patients positive by immunofluorescence, 48 were also positive by ELISA while all the 154 LKM1 negative subjects were also negative by ELISA. There was a high degree of association between IFL and ELISA as demonstrated by a kappa reliability value of 0.96. The absorbance values by ELISA correlated with immunofluorescence LKM1 titres both in autoimmune hepatitis (r = 0.74, p < 0.001) and HCV infection (r = 0.67, p < 0.001). The simple, objective ELISA described has the potential to replace the standard immunofluorescence technique.
Bovine herpesvirus 1: within-herd seroprevalence and antibody levels in bulk-tank milk.
Martínez, S; Yus, E; Sanjuán, M L; Camino, F; Eiras, M C; Arnaiz, I; Diéguez, F J
2016-12-01
The aim of the present study was to establish a relationship between the results obtained with the enzyme-linked immunosorbent assay (ELISA) technique for antibodies (against bovine herpesvirus 1) in serum and those in milk at the herd level. For this purpose, 275 samples of bulk-tank milk were analysed with glycoprotein E (gE) antibody ELISA and 207 more were analysed with glycoprotein B (gB) antibody ELISA (482 in total). All of these samples came from dairy herds whose seroprevalence was also evaluated. The results of this study were then used to analyse the sensitivity of the bulk-tankmilk test in detecting herds with a high risk of active infection (>60% seroprevalence) and its specificity in detecting those with few (<20%) or no seropositive animals. In regard to the reference test (results in blood serum), the sensitivity of the bulk-tankmilk test in detecting herds with >60% seropositive animals was 100% for both gE and gB ELISAs. The specificity figures, for gE and gB ELISAs, respectively, were 88.4% and 99.1% for infection-free herds and 72.6% and 96% for herds with <20% seroprevalence. In a quantitative approach, Pearson's correlation coefficients, reported as a measure of linear association between herd seroprevalences and transformed optical density values recorded in bulk-tank milk, were -0.63 for gE ELISA and 0.67 for gB ELISA. © OIE (World Organisation for Animal Health), 2016.
Hoane, Jessica S; Morrow, Jennifer K; Saville, William J; Dubey, J P; Granstrom, David E; Howe, Daniel K
2005-09-01
Sarcocystis neurona is the primary causative agent of equine protozoal myeloencephalitis (EPM), a common neurologic disease of horses in the Americas. We have developed a set of enzyme-linked immunosorbent assays (ELISAs) based on the four major surface antigens of S. neurona (SnSAGs) to analyze the equine antibody response to S. neurona. The SnSAG ELISAs were optimized and standardized with a sample set of 36 equine sera that had been characterized by Western blotting against total S. neurona parasite antigen, the current gold standard for S. neurona serology. The recombinant SnSAG2 (rSnSAG2) ELISA showed the highest sensitivity and specificity at 95.5% and 92.9%, respectively. In contrast, only 68.2% sensitivity and 71.4% specificity were achieved with the rSnSAG1 ELISA, indicating that this antigen may not be a reliable serological marker for analyzing antibodies against S. neurona in horses. Importantly, the ELISA antigens did not show cross-reactivity with antisera to Sarcocystis fayeri or Neospora hughesi, two other equine parasites. The accuracy and reliability exhibited by the SnSAG ELISAs suggest that these assays will be valuable tools for examining the equine immune response against S. neurona infection, which may help in understanding the pathobiology of this accidental parasite-host interaction. Moreover, with modification and further investigation, the SnSAG ELISAs have potential for use as immunodiagnostic tests to aid in the identification of horses affected by EPM.
Hoane, Jessica S.; Morrow, Jennifer K.; Saville, William J.; Dubey, J. P.; Granstrom, David E.; Howe, Daniel K.
2005-01-01
Sarcocystis neurona is the primary causative agent of equine protozoal myeloencephalitis (EPM), a common neurologic disease of horses in the Americas. We have developed a set of enzyme-linked immunosorbent assays (ELISAs) based on the four major surface antigens of S. neurona (SnSAGs) to analyze the equine antibody response to S. neurona. The SnSAG ELISAs were optimized and standardized with a sample set of 36 equine sera that had been characterized by Western blotting against total S. neurona parasite antigen, the current gold standard for S. neurona serology. The recombinant SnSAG2 (rSnSAG2) ELISA showed the highest sensitivity and specificity at 95.5% and 92.9%, respectively. In contrast, only 68.2% sensitivity and 71.4% specificity were achieved with the rSnSAG1 ELISA, indicating that this antigen may not be a reliable serological marker for analyzing antibodies against S. neurona in horses. Importantly, the ELISA antigens did not show cross-reactivity with antisera to Sarcocystis fayeri or Neospora hughesi, two other equine parasites. The accuracy and reliability exhibited by the SnSAG ELISAs suggest that these assays will be valuable tools for examining the equine immune response against S. neurona infection, which may help in understanding the pathobiology of this accidental parasite-host interaction. Moreover, with modification and further investigation, the SnSAG ELISAs have potential for use as immunodiagnostic tests to aid in the identification of horses affected by EPM. PMID:16148170
Liu, Changqi; Chhabra, Guneet S; Zhao, Jing; Zaffran, Valerie D; Gupta, Sahil; Roux, Kenneth H; Gradziel, Thomas M; Sathe, Shridhar K
2017-10-01
A commercially available monoclonal antibody (mAb)-based direct sandwich enzyme-linked immunosorbent assay (ELISA) kit (BioFront Technologies, Tallahassee, Fla., U.S.A.) was compared with an in-house developed mAb 4C10-based ELISA for almond detection. The assays were comparable in sensitivity (limit of detection < 1 ppm full fat almond, limit of quantification < 5 ppm full fat almond), specificity (no cross-reactivity with 156 tested foods at a concentration of 100000 ppm whole sample), and reproducibility (intra- and interassay variability < 15% CV). The target antigens were stable and detectable in whole almond seeds subjected to autoclaving, blanching, frying, microwaving, and dry roasting. The almond recovery ranges for spiked food matrices were 84.3% to 124.6% for 4C10 ELISA and 81.2% to 127.4% for MonoTrace ELISA. The almond recovery ranges for commercial and laboratory prepared foods with declared/known almond amount were 30.9% to 161.2% for 4C10 ELISA and 38.1% to 207.6% for MonoTrace ELISA. Neither assay registered any false-positive or negative results among the tested commercial and laboratory prepared samples. Ability to detect and quantify trace amounts of almonds is important for improving safety of almond sensitive consumers. Two monoclonal antibody-based ELISAs were compared for almond detection. The information is useful to food industry, regulatory agencies, scientific community, and almond consumers. © 2017 Institute of Food Technologists®.
Galvin, Pamela; Gildea, Sarah; Arkins, Sean; Walsh, Cathal; Cullinane, Ann
2013-12-01
Antibodies against equine influenza virus (EIV) are traditionally quantified by haemagglutination inhibition (HI) or single radial haemolysis (SRH). To evaluate an ELISA for the detection of antibodies against influenza nucleoprotein in the diagnosis and surveillance of equine influenza (EI). The ELISA was compared with the SRH and HI tests. Serial serum samples from 203 naturally and 14 experimentally infected horses, from 60 weanlings following primary vaccination with five different vaccines (two whole inactivated vaccines, two ISCOM-based subunit vaccines and a recombinant canarypox virus vaccine) and from 44 adult horses following annual booster vaccination with six different vaccines were analysed. Fewer seroconversions were detected in clinical samples by ELISA than by SRH or HI but ELISA was more sensitive than SRH in naïve foals post-experimental infection. The ELISA did not detect the antibody response to vaccination with the recombinant canarypox virus vaccine confirming the usefulness of the combination of this kit and vaccine to differentiate between naturally infected and vaccinated horses, that is, DIVA. No DIVA capacity was evident with the other vaccines. The results suggest that this ELISA is a useful supplementary test for the diagnosis of EI although less sensitive than HI or SRH. It is an appropriate test for EI surveillance in a naïve population and may be combined with the recombinant canarypox virus vaccine but not with other commercially available subunit vaccines, in a DIVA strategy. © 2013 Blackwell Publishing Ltd.
Role of specific immunoglobulin E in diagnosis of acute toxoplasma infection and toxoplasmosis.
Wong, S Y; Hajdu, M P; Ramirez, R; Thulliez, P; McLeod, R; Remington, J S
1993-11-01
Toxoplasma immunoglobulin E (IgE) antibodies were evaluated in an immunosorbent agglutination assay (ISAGA) and an enzyme-linked immunosorbent assay (ELISA) to determine their usefulness in the diagnosis of acute infection with Toxoplasma gondii. IgE antibodies were not detected in serum specimens from otherwise seronegative individuals, individuals with chronic toxoplasma infection, or infants without congenital toxoplasmosis. In contrast, they were detected in pregnant women who seroconverted during gestation (100% by ELISA, 63% by ISAGA), patients with toxoplasmic lymphadenopathy (96% by ELISA, 88% by ISAGA), infants with signs of congenital toxoplasmosis which prompted serologic testing in the postnatal period (92% by ELISA, 67% by ISAGA), children and adults with toxoplasmic chorioretinitis (36% by ELISA, 18% by ISAGA), and adult patients with AIDS and toxoplasmic encephalitis (33% by ELISA, 25% by ISAGA). In many of the serum specimens, the titer of IgE antibodies detected by the ISAGA were close to or at the positive cutoff value. The duration of detectable IgE antibodies in patients with acute infections varied considerably among individuals but showed a trend toward a briefer duration by the ISAGA than by the ELISA. These results reveal that recrudescence of IgE antibodies in patients with reactivated chronic infection (toxoplasmic chorioretinitis and toxoplasmic encephalitis) may be useful diagnostically and that demonstration of toxoplasma IgE antibodies is a useful adjunct to currently available serologic tests for the diagnosis of acute toxoplasma infection and toxoplasmosis.
Role of specific immunoglobulin E in diagnosis of acute toxoplasma infection and toxoplasmosis.
Wong, S Y; Hajdu, M P; Ramirez, R; Thulliez, P; McLeod, R; Remington, J S
1993-01-01
Toxoplasma immunoglobulin E (IgE) antibodies were evaluated in an immunosorbent agglutination assay (ISAGA) and an enzyme-linked immunosorbent assay (ELISA) to determine their usefulness in the diagnosis of acute infection with Toxoplasma gondii. IgE antibodies were not detected in serum specimens from otherwise seronegative individuals, individuals with chronic toxoplasma infection, or infants without congenital toxoplasmosis. In contrast, they were detected in pregnant women who seroconverted during gestation (100% by ELISA, 63% by ISAGA), patients with toxoplasmic lymphadenopathy (96% by ELISA, 88% by ISAGA), infants with signs of congenital toxoplasmosis which prompted serologic testing in the postnatal period (92% by ELISA, 67% by ISAGA), children and adults with toxoplasmic chorioretinitis (36% by ELISA, 18% by ISAGA), and adult patients with AIDS and toxoplasmic encephalitis (33% by ELISA, 25% by ISAGA). In many of the serum specimens, the titer of IgE antibodies detected by the ISAGA were close to or at the positive cutoff value. The duration of detectable IgE antibodies in patients with acute infections varied considerably among individuals but showed a trend toward a briefer duration by the ISAGA than by the ELISA. These results reveal that recrudescence of IgE antibodies in patients with reactivated chronic infection (toxoplasmic chorioretinitis and toxoplasmic encephalitis) may be useful diagnostically and that demonstration of toxoplasma IgE antibodies is a useful adjunct to currently available serologic tests for the diagnosis of acute toxoplasma infection and toxoplasmosis. PMID:8263181
Ma, Xiaoyue; Niezgoda, Michael; Blanton, Jesse D; Recuenco, Sergio; Rupprecht, Charles E
2012-08-03
Two major techniques are currently used to estimate rabies virus antibody values: neutralization assays, such as the rapid fluorescent focus inhibition test (RFFIT), and enzyme-linked immunosorbent assays (ELISAs). The RFFIT is considered the gold standard assay and has been used to assess the titer of rabies virus neutralizing antibodies for more than three decades. In the late 1970s, ELISA began to be used to estimate the level of rabies virus antibody and has recently been used by some laboratories as an alternate screening test for animal sera. Although the ELISA appears simpler, safer and more efficient, the assay is less sensitive in detecting low values of rabies virus neutralizing antibodies than neutralization tests. This study was designed to evaluate a new ELISA-based method for detecting rabies virus binding antibody. This new technique uses electro-chemi-luminescence labels and carbon electrode plates to detect binding events. In this comparative study, the RFFIT and the new ELISA-based technique were used to evaluate the level of rabies virus antibodies in human and animal serum samples. By using a conservative approximation of 0.15 IU/ml as a cutoff point, the new ELISA-based technique demonstrated a sensitivity of 100% and a specificity of 95% for human samples and for experimental animal samples. The sensitivity and specificity for field animal samples was 96% and 95%, respectively. The preliminary results from this study appear promising and demonstrate a higher sensitivity than traditional ELISA methods. Published by Elsevier Ltd.
Lee, E.A.; Zimmerman, L.R.; Bhullar, B.S.; Thurman, E.M.
2002-01-01
A novel, sensitive, linker-assisted enzyme-linked immunosorbent assay (L'ELISA) was compared to on-line solidphase extraction (SPE) with high-performance liquid chromatography/mass spectrometry (HPLC/MS) for the analysis of glyphosate in surface water and groundwater samples. The L'ELISA used succinic anhydride to derivatize glyphosate, which mimics the epitotic attachment of glyphosate to horseradish peroxidase hapten. Thus, L'ELISA recognized the derivatized glyphosate more effectively (detection limit of 0.1 μg/L) and with increased sensitivity (10-100 times) over conventional ELISA and showed the potential for other applications. The precision and accuracy of L'ELISA then was compared with on-line SPE/HPLC/MS, which detected glyphosate and its degradate derivatized with 9-fluorenylmethyl chloroformate using negative-ion electrospray (detection limit 0.1 μg/L, relative standard deviation ±15%). Derivatization efficiency and matrix effects were minimized by adding an isotope-labeled glyphosate (2-13C15N). The accuracy of L'ELISA gave a false positive rate of 18% between 0.1 and 1.0 μg/L and a false positive rate of only 1% above 1.0 μg/L. The relative standard deviation was ±20%. The correlation of L'ELISA and HPLC/MS for 66 surface water and groundwater samples was 0.97 with a slope of 1.28, with many detections of glyphosate and its degradate in surface water but not in groundwater.
SUN, Yu-Ling; YEN, Chon-Ho; TU, Ching-Fu
2013-01-01
ABSTRACT Loop-mediated isothermal amplification (LAMP) combined with enzyme-linked immunosorbent assay (LAMP–ELISA) and with lateral flow dipstick (LAMP–LFD) are rapid, sensitive and specific methods for the visual detection of clinical pathogens. In this study, LAMP–ELISA and LAMP–LFD were developed for the visual detection of canine parvovirus (CPV). For LAMP, a set of four primers (biotin-labeled forward inner primers) was designed to specifically amplify a region of the VP2 gene of CPV. The optimum time and temperature for LAMP were 60 min and 65°C, respectively. The specific capture oligonucleotide probes, biotin-labeled CPV probe for LAMP–ELISA and fluorescein isothiocyanate-labeled CPV probe for LAMP–LFD were also designed for hybridization with LAMP amplicons on streptavidin-coated wells and LFD strips, respectively. For the comparison of detection sensitivity, conventional PCR and LAMP for CPV detection were also performed. The CPV detection limits by PCR, PCR–ELISA, LAMP, LAMP–ELISA and LAMP–LFD were 102, 102, 10−1, 10−1 and 10−1 TCID50/ml, respectively. In tests using artificially contaminated dog fecal samples, the samples with CPV inoculation levels of ≥1 TCID50/ml gave positive results by both LAMP–ELISA and LAMP–LFD. Our data indicated that both LAMP–ELISA and LAMP–LFD are promising as rapid, sensitive and specific methods for an efficient diagnosis of CPV infection. PMID:24334855
Torrent, F; Villena, A; Lee, P A; Fuchs, W; Bergmann, S M; Coll, J M
2016-10-01
Recombinantly expressed fragments of the protein encoded by ORF149 (pORF149), a structural protein from the common- and koi-carp-infecting cyprinid herpesvirus-3 (CyHV-3) that was previously shown to be antigenic, were used to obtain evidence that its amino-terminal part contains immunodominant epitopes in fish populations that survived the infection. To obtain such evidence, nonspecific binding of carp serum tetrameric IgM had to be overcome by a novel ELISA protocol (rec2-ELISA). Rec2-ELISA involved pre-adsorption of carp sera with a heterologous recombinant fragment before incubation with pORF149 fragments and detection with anti-carp IgM monoclonal antibodies. Only in this way was it possible to distinguish between sera from uninfected and survivor carp populations. Although IgM from survivors recognised pORF149 fragments to a lesser degree than whole virus, specificity was confirmed by correlation of rec2- and CyHV-3-ELISAs, inhibition of rec2-ELISA by an excess of frgIIORF149, ELISA using IgM-capture, Western blotting, and reduction of reactivity in CyHV-3-ELISA by pre-adsorption of sera with frgIIORF149. The similarity of IgM-binding profiles between frgIORF149 (amino acid residues 42-629) and frgIIORF149 (42-159) and their reactivities with previously described anti-CyHV-3 monoclonal antibodies confirmed that most pORF149 epitopes were localised in its amino-terminal part.
Kulkarni, Diwakar D; Venkatesh, Govindarajalu; Tosh, Chakradhar; Patel, Priyanka; Mashoria, Anita; Gupta, Vandana; Gupta, Sourabh; D, Senthilkumar
2016-01-01
The recombinant viral protein-based indirect enzyme-linked immunosorbent assay (ELISA) is a cost-effective, safe, specific, and rapid tool to diagnose the viral infection. Nipah virus nucleocapsid (NiV-N) protein was expressed in Escherichia coli and purified by histidine tag-based affinity chromatography. The N protein was selected based on its immuno dominance and conservation among different NiV strains. An indirect immunoglobulin G (IgG) enzyme-linked immunosorbent assay (ELISA) for swine sera was optimized using the recombinant NiV-N protein as an antigen along with negative and positive controls. The background reading was blocked using skim milk powder and chicken serum. A total number of 1709 swine serum samples from various states of India were tested with indirect ELISA and Western blot. The test was considered positive only when its total reactivity reading was higher than 0.2 cut-off value and the ratio of the total reactivity to the background reading was more than 2.0. Since specificity is high for Western blotting it was used as standard test for comparison of results of indirect ELISA. Sensitivity and specificity of indirect ELISA was 100% and 98.7%, respectively, in comparison with Western blotting. Recombinant N protein-based ELISA can be used in screening large number of serum samples for epidemiological investigations in developing countries where high containment laboratories are not available to handle this zoonotic virus.
Nimata, Masaomi; Okada, Hideki; Kurihara, Kei; Sugimoto, Tsukasa; Honjoh, Tsutomu; Kuroda, Kazuhiko; Yano, Takeo; Tachibana, Hirofumi; Shoji, Masahiro
2018-01-01
Food allergy is a serious health issue worldwide. Implementing allergen labeling regulations is extremely challenging for regulators, food manufacturers, and analytical kit manufacturers. Here we have developed an "amino acid sequence immunoassay" approach to ELISA. The new ELISA comprises of a monoclonal antibody generated via an analyte specific peptide antigen and sodium lauryl sulfate/sulfite solution. This combination enables the antibody to access the epitope site in unfolded analyte protein. The newly developed ELISA recovered 87.1%-106.4% ovalbumin from ovalbumin-incurred model processed foods, thereby demonstrating its applicability as practical egg allergen determination. Furthermore, the comparison of LC-MS/MS and the new ELISA, which targets the amino acid sequence conforming to the LC-MS/MS detection peptide, showed a good agreement. Consequently the harmonization of two methods was demonstrated. The complementary use of the new ELISA and LC-MS analysis can offer a wide range of practical benefits in terms of easiness, cost, accuracy, and efficiency in food allergen analysis. In addition, the new assay is attractive in respect to its easy antigen preparation and predetermined specificity. Graphical abstract The ELISA composing of the monoclonal antibody targeting the amino acid sequence conformed to LC-MS detection peptide, and the protein conformation unfolding reagent was developed. In ovalbumin determination, the developed ELISA showed a good agreement with LC-MS analysis. Consequently the harmonization of immunoassay with LC-MS analysis by using common target amino acid sequence was demonstrated.
Watanabe, Eiki; Kobara, Yuso; Miyake, Shiro
2013-06-01
With the aim of expanding the applicability of a kit-based enzyme-linked immunosorbent assay (ELISA) for the neonicotinoid insecticide thiamethoxam, the ELISA was newly applied to three kinds of agricultural samples (green pepper, eggplant and spinach). To offer the ELISA as a screening analysis for thiamethoxam residues, a rapid and simple method of extraction by hand-shaking was used, and speed-up and simplification of the sample treatment before the ELISA analysis were examined. Finally, the validity of the ELISA combined with the proposed extraction method was verified against a reference high-performance liquid chromatography (HPLC) method using real-world agricultural samples. There were no marked matrix effects derived from green pepper and eggplant extracts. On the other hand, although the effect due to a pigment in spinach extract on the assay performance was significant, it was effectively avoided by increasing the dilution level of the spinach extract. For thiamethoxam-spiked samples, acceptable recoveries of 97.9-109.1% and coefficients of variation of 0.3-11.5% were obtained. Inspection of the validity of the ELISA by comparison with the reference HPLC method showed that the two analytical results were very similar, and a high correlation was found between them (r>0.997). The evaluated ELISA combined with hand-shaking extraction provided a rapid and simple screening analysis that was quantitative and reliable for the detection of thiamethoxam in complex agricultural products. © 2012 Society of Chemical Industry.
Galkin, O Yu; Besarab, A B; Lutsenko, T N
2017-01-01
The goal of this work was to study sensitivity and specificity of the developed ELISA set for the identification of IgG antibodies against Chlamydia trachomatis HSP-60 (using biotinylated tyramine-based signal amplification system). The study was conducted using a panel of characterized sera, as well as two reference ELISA sets of similar purpose. According to the results of ELISA informative value parameters, the ELISA we have developed showed the highest specificity and sensitivity parameters (no false negative or false positive results were registered). In 4 out of 15 intralaboratory panel serum samples initially identified as negative, anti-HSP-60 IgG-antibodies test result in reference ELISA sets upon dilution changed from negative to positive. The nature of titration curves of false negative sera and commercial monoclonal antibodies А57-В9 against C. trachomatis HSP-60 after incubation for 24 h was indicative of the presence of anti-idiotypic antibodies in these samples. Upon sera dilution, idiotypic-anti-idiotypic complexes dissociated, which caused the change of test result. High informative value of the developed ELISA set for identification of IgG antibodies against C. trachomatis HSP-60 has been proven. Anti-idiotypic antibodies possessing C. trachomatis anti-HSP-60 activity and being one of the causes of false negative results of the relevant ELISA-based tests have been identified in blood sera of individuals infected with chlamydial genitourinary infection agents.
Direct Competitive Enzyme-Linked Immunosorbent Assay (ELISA).
Kohl, Thomas O; Ascoli, Carl A
2017-07-05
The competitive enzyme-linked immunosorbent assay (ELISA) (cELISA; also called an inhibition ELISA) is designed so that purified antigen competes with antigen in the test sample for binding to an antibody that has been immobilized in microtiter plate wells. The same concept works if the immobilized molecule is antigen and the competing molecules are purified labeled antibody versus antibody in a test sample. Direct cELISAs incorporate labeled antigen or antibody, whereas indirect assay configurations use reporter-labeled secondary antibodies. The cELISA is very useful for determining the concentration of small-molecule antigens in complex sample mixtures. In the direct cELISA, antigen-specific capture antibody is adsorbed onto the microtiter plate before incubation with either known standards or unknown test samples. Enzyme-linked antigen (i.e., labeled antigen) is also added, which can bind to the capture antibody only when the antibody's binding site is not occupied by either the antigen standard or antigen in the test samples. Unbound labeled and unlabeled antigens are washed away and substrate is added. The amount of antigen in the standard or the test sample determines the amount of reporter-labeled antigen bound to antibody, yielding a signal that is inversely proportional to antigen concentration within the sample. Thus, the higher the antigen concentration in the test sample, the less labeled antigen is bound to the capture antibody, and hence the weaker is the resultant signal. © 2017 Cold Spring Harbor Laboratory Press.
Exploiting Inhibitory Siglecs to Combat Food Allergies
2017-10-01
such as ELISAs . Shiteng and Kevin Worrell participated in groups meetings, regularly presenting their research updates. Dr. Macauley worked closely...transferred the cells into naïve animals and then immunized with Ara h 2. She also contributed by running some ELISA experiments. Funding Support...procedures and peanut challenges. She also assisted with cellular studies, flow cytometry, and ELISA . Kelly performed the human CD33 basophil assays as
Exploiting Inhibitory Siglecs to Combat Food Allergies
2017-10-01
project including mouse handling, liposome preparation, and in vitro assays, such as ELISAs . Shiteng and Kevin Worrell participated in groups...h 2. She also contributed by running some ELISA experiments. Funding Support: N/A Name: Kelly Orgel Project Role: Graduate Student (UNC...flow cytometry, and ELISA . Kelly performed the human CD33 basophil assays as well. Funding Support: N/A Name: Johanna Smeekens, PhD Project
USDA-ARS?s Scientific Manuscript database
An accurate and simple-to-perform new version of a competitive ELISA (cELISA) kit that became commercially available in 2015 for testing of cattle for antibody to Anaplasma marginale was validated for detection of Anaplasma ovis antibody in domestic sheep. True positives and negatives were identifie...
Gabriel, Martin; Adomeh, Donatus I.; Ehimuan, Jacqueline; Oyakhilome, Jennifer; Omomoh, Emmanuel O.; Ighodalo, Yemisi; Olokor, Thomas; Bonney, Kofi; Pahlmann, Meike; Emmerich, Petra; Lelke, Michaela; Brunotte, Linda; Ölschläger, Stephan; Thomé-Bolduan, Corinna; Becker-Ziaja, Beate; Busch, Carola; Odia, Ikponmwosa; Ogbaini-Emovon, Ephraim; Okokhere, Peter O.; Okogbenin, Sylvanus A.; Akpede, George O.; Schmitz, Herbert; Asogun, Danny A.
2018-01-01
Background The classical method for detection of Lassa virus-specific antibodies is the immunofluorescence assay (IFA) using virus-infected cells as antigen. However, IFA requires laboratories of biosafety level 4 for assay production and an experienced investigator to interpret the fluorescence signals. Therefore, we aimed to establish and evaluate enzyme-linked immunosorbent assays (ELISA) using recombinant Lassa virus nucleoprotein (NP) as antigen. Methodology/Principal findings The IgM ELISA is based on capturing IgM antibodies using anti-IgM, and the IgG ELISA is based on capturing IgG antibody–antigen complexes using rheumatoid factor or Fc gamma receptor CD32a. Analytical and clinical evaluation was performed with 880 sera from Lassa fever endemic (Nigeria) and non-endemic (Ghana and Germany) areas. Using the IFA as reference method, we observed 91.5–94.3% analytical accuracy of the ELISAs in detecting Lassa virus-specific antibodies. Evaluation of the ELISAs for diagnosis of Lassa fever on admission to hospital in an endemic area revealed a clinical sensitivity for the stand-alone IgM ELISA of 31% (95% CI 25–37) and for combined IgM/IgG detection of 26% (95% CI 21–32) compared to RT-PCR. The specificity of IgM and IgG ELISA was estimated at 96% (95% CI 93–98) and 100% (95% CI 99–100), respectively, in non-Lassa fever patients from non-endemic areas. In patients who seroconverted during follow-up, Lassa virus-specific IgM and IgG developed simultaneously rather than sequentially. Consistent with this finding, isolated IgM reactivity, i.e. IgM in the absence of IgG, had no diagnostic value. Conclusions/Significance The ELISAs are not equivalent to RT-PCR for early diagnosis of Lassa fever; however, they are of value in diagnosing patients at later stage. The IgG ELISA may be useful for epidemiological studies and clinical trials due its high specificity, and the higher throughput rate and easier operation compared to IFA. PMID:29596412
Pancreatic Reference Set Application- Ann Killary-MD Anderson (2012) — EDRN Public Portal
ELISA assays. We propose to screen a two gene panel (TNC/TFPI) from functional genomic pathways approaches, by ELISA assays, in a collection of blinded plasma samples with the PCCG. In subsequent years, we will add to this panel additional candidates identified in the parent EDRN grant that are in the migration signature network or the 20q amplicon. For ELISA assays, we will utilize commercially available kits. Plasma levels of the predominant isoform of TNC, TNC-large variant (TNC-L) will be determined using a Human Tenascin-C Large (HMV) (FNIII-B) ELISA kit (IBL-America, Minneapolis, MN), which detects human TNC high molecular weight variant by sandwich ELISA. Plasma TFPI levels will be determined using a commercially available Quantikine Human TFPI ELISA kit (DTFP10) (R&D; Systems, Inc. Minneapolis, MN), which detects predominantly free TFPI and a very small percentage of LDL and HDL-bound TFPI by sandwich ELISA. Additional ELISA assays will be added in years 2-3 using ingenuity network analysis to identify secreted proteins that interact with migration signature proteins identified using functional genomic approaches. In addition, Dr. Sen’s lab has identified candidate biomarkers mapping with the 20q amplicon and which are both amplified and overexpressed as well as are secreted proteins. In years 2-3, we will examine all candidate markers by ELISA to determine 20q pathway markers increase the sensitivity and specificity of the 3p panel. Validation of a 4 miR Panel. For assaying the levels of miRs in plasma, qRT-PCR assays will be performed, as described (9). For the selected panel of miRs, we propose to develop a high throughput qRT-PCR assay by adapting our published method to a 96 well format where the critical steps of purification, such as LiCl precipitation and DNAse treatments will be done in successive steps in the same plates. In years 2-3, additional miRs that target both the 20q amplicon genes as well as miRs that target migration genes in Dr. Killary’
Praud, Anne; Champion, Jean-Luc; Corde, Yannick; Drapeau, Antoine; Meyer, Laurence; Garin-Bastuji, Bruno
2012-07-09
Brucella ovis causes an infectious disease responsible for infertility and subsequent economic losses in sheep production. The standard serological test to detect B. ovis infection in rams is the complement fixation test (CFT), which has imperfect sensitivity and specificity in addition to technical drawbacks. Other available tests include the indirect enzyme-linked immunosorbent assays (I-ELISA) but no I-ELISA kit has been fully evaluated.The study aimed to compare an I-ELISA kit and the standard CFT. Our study was carried out on serum samples from 4599 rams from the South of France where the disease is enzootic. A Bayesian approach was used to estimate tests characteristics (diagnostic sensitivity, Se and diagnostic specificity, Sp). The tests were then studied together in order to optimise testing strategies to detect B. ovis. After optimising the cut-off values in order to avoid doubtful results without deteriorating the concordance between the results of the two tests, the I-ELISA appeared to be slightly more sensitive than CFT (Se I-ELISA=0.917 [0.822; 0.992], 95% Credibility Interval (CrI) compared to Se CFT=0.860 [0.740; 0.967], 95% CrI). However, CFT was slightly more specific than I-ELISA (Sp CFT=0.988 [0.947; 1.0], 95% CrI) compared to Sp I-ELISA =0.952 [0.901; 1.0], 95% CrI).The tests were then associated with two different interpretation schemes. The series association increased the specificity of screening and could be used for pre-movement testing in rams from uninfected flocks. The parallel association increased sequence sensitivity, thus appearing more suitable for eradicating the disease in infected flocks. The high sensitivity and acceptable specificity of this I-ELISA kit support its potential interest to avoid the limitations of CFT. The two tests could also be used together or combined with other diagnostic methods such as semen culture to improve the testing strategy. The choice of test sequence and interpretation criteria depends on the epidemiological context, screening objectives and the financial and practical constraints.
Persichetti, Maria Flaminia; Solano-Gallego, Laia; Vullo, Angela; Masucci, Marisa; Marty, Pierre; Delaunay, Pascal; Vitale, Fabrizio; Pennisi, Maria Grazia
2017-03-13
Anti-Leishmania antibodies are increasingly investigated in cats for epidemiological studies or for the diagnosis of clinical feline leishmaniosis. The immunofluorescent antibody test (IFAT), the enzyme-linked immunosorbent assay (ELISA) and western blot (WB) are the serological tests more frequently used. The aim of the present study was to assess diagnostic performance of IFAT, ELISA and WB to detect anti-L. infantum antibodies in feline serum samples obtained from endemic (n = 76) and non-endemic (n = 64) areas and from cats affected by feline leishmaniosis (n = 21) by a Bayesian approach without a gold standard. Cut-offs were set at 80 titre for IFAT and 40 ELISA units for ELISA. WB was considered positive in presence of at least a 18 KDa band. Statistical analysis was performed through a written routine with MATLAB software in the Bayesian framework. The latent data and observations from the joint posterior were simulated in the Bayesian approach by an iterative Markov Chain Monte Carlo technique using the Gibbs sampler for estimating sensitivity and specificity of the three tests. The median seroprevalence in the sample used for evaluating the performance of tests was estimated at 0.27 [credible interval (CI) = 0.20-0.34]. The median sensitivity of the three different methods was 0.97 (CI: 0.86-1.00), 0.75 (CI: 0.61-0.87) and 0.70 (CI: 0.56-0.83) for WB, IFAT and ELISA, respectively. Median specificity reached 0.99 (CI: 0.96-1.00) with WB, 0.97 (CI: 0.93-0.99) with IFAT and 0.98 (CI: 0.94-1.00) with ELISA. IFAT was more sensitive than ELISA (75 vs 70%) for the detection of subclinical infection while ELISA was better for diagnosing clinical leishmaniosis when compared with IFAT (98 vs 97%). The overall performance of all serological techniques was good and the most accurate test for anti-Leishmania antibody detection in feline serum samples was WB.
Lee, Augustine S; Finkielman, Javier D; Peikert, Tobias; Hummel, Amber M; Viss, Margaret A; Specks, Ulrich
2005-12-20
Testing for antineutrophil cytoplasmic antibodies (ANCA) reacting with proteinase 3 (PR3) is part of the routine diagnostic evaluation of patients with small vessel vasculitis. For PR3-ANCA detection, capture ELISAs are reported to be superior to direct ELISAs. Standard capture ELISAs, in which PR3 is anchored by anti-PR3 monoclonal antibodies (moAB), have two potential disadvantages. First, the capturing moAB may compete for epitopes recognized by some PR3-ANCA, causing occasional false-negative results. Second, the capture of recombinant PR3 mutant molecules becomes unpredictable as modifications of specific conformational epitopes may not only affect the binding of PR3-ANCA, but also the affinity of the capturing anti-PR3 moAB. Here, we describe a new capture ELISA, and its application for PR3-ANCA detection. This new assay is based on the standardized capture of a variety of different carboxy-terminally c-myc tagged recombinant ANCA target antigens using anti-c-myc coated ELISA plates. Antigen used include c-myc tagged human rPR3 variants (mature and pro-form conformations), mouse mature rPR3 and human recombinant neutrophil elastase. This new anti-c-myc-capture ELISA for PR3-ANCA detection has an intra- and inter-assay coefficient of variation of 3.6% to 7.7%, and 15.8% to 18.4%, respectively. The analytical sensitivity and specificity for PR3-ANCA positive serum samples were 93% and 100%, respectively when rPR3 with mature conformation was used as target antigen, and 83% and 100% when the pro-enzyme conformation was employed. In conclusion, this new anti-c-myc capture ELISA compares favorably to our standard capture ELISA for PR3-ANCA detection, enables the unified capture of different ANCA target antigens through binding to a c-myc tag, and allows capture of rPR3 mutants necessary for PR3-ANCA epitope mapping studies.
Determination of PCBs in fish using enzyme-linked immunosorbent assay (ELISA)
Lasrado, J.A.; Santerre, C.R.; Zajicek, J.L.; Stahl, J.R.; Tillitt, D.E.; Deardorff, D.
2003-01-01
Polychlorinated biphenyls (PCBs) were determined in fish tissue using an enzyme-linked immunosorbent assay (ELISA). Standard curves for Aroclor 1248, 1254, and 1260 in catfish tissue were developed with ranges from 0.05 to 0.5 ppm and 0.5 to 5.0 ppm. Wild fish were initially analyzed using gas chromatography/electron-capture detection (GC/ECD) and those having residues within the standard curve ranges were analyzed with ELISA. Results obtained using ELISA and GC/ECD were not significantly different (p < 0.05) from 0.05 to 0.5 ppm. From 0.5 to 5.0 ppm, the standard curve for Aroclor 1254 was the best predictor of total PCB in wild fish samples.
Joseph, Siju; Thomas, Naicy; Thangapandian, E; Singh, Vijendra P; Verma, Rishendra; Srivastava, S K
2012-03-01
A 21-kDa leptospiral lipoprotein (LipL21) was evaluated for its diagnostic potential to detect bovine leptospirosis by ELISA. Both native LipL21 (nLipL21) and recombinant LipL21 (rLipL21) proteins were tested and compared regarding diagnostic efficiency, and no statistically significant difference was observed. The sensitivity of rLipL21 ELISA for 62 microscopic agglutination test (MAT) positive sera was 100% and the specificity with 378 MAT negative sera was 97.09%. Thus, rLipL21 protein-based ELISA could be used as an alternative to MAT for the diagnosis of bovine leptospirosis.
Shafee, Muhammad; Rabbani, Masood; Sheikh, Ali Ahmad; Ahmad, Mansoor Din; Razzaq, Abdul
2011-01-24
A total of 200 milk samples from cattle (n = 86) and buffalo (n = 114) were evaluated using milk ring test (MRT) and indirect enzyme-linked immunosorbent assay (i-ELISA). The overall prevalence was found to be 3% and 8.5% in cattle and buffaloes using MRT and i-ELISA, respectively. The prevalence was 4.6% and 1.7% in cattle and buffalo using MRT, respectively, while i-ELISA exhibited 20% and 0% in cattle and buffalo, respectively. The prevalence was higher in government dairy farm, compared to privately owned dairy farm. This paper points out an alarming situation in the target area with respect to the public health significance.
Shafee, Muhammad; Rabbani, Masood; Sheikh, Ali Ahmad; Ahmad, Mansoor din; Razzaq, Abdul
2011-01-01
A total of 200 milk samples from cattle (n = 86) and buffalo (n = 114) were evaluated using milk ring test (MRT) and indirect enzyme-linked immunosorbent assay (i-ELISA). The overall prevalence was found to be 3% and 8.5% in cattle and buffaloes using MRT and i-ELISA, respectively. The prevalence was 4.6% and 1.7% in cattle and buffalo using MRT, respectively, while i-ELISA exhibited 20% and 0% in cattle and buffalo, respectively. The prevalence was higher in government dairy farm, compared to privately owned dairy farm. This paper points out an alarming situation in the target area with respect to the public health significance. PMID:21331157
Watanabe, Eiki; Miyake, Shiro
2018-06-05
Easy-to-use commercial kit-based enzyme-linked immunosorbent assays (ELISAs) have been used to detect neonicotinoid dinotefuran, clothianidin and imidacloprid in Chinese chives, which are considered a troublesome matrix for chromatographic techniques. Based on their high water solubility, water was used as an extractant. Matrix interference could be avoided substantially just diluting sample extracts. Average recoveries of insecticides from spiked samples were 85-113%, with relative standard deviation of <15%. The concentrations of insecticides detected from the spiked samples with the proposed ELISA methods correlated well with those by the reference high-performance liquid chromatography (HPLC) method. The residues analyzed by the ELISA methods were consistently 1.24 times that found by the HPLC method, attributable to loss of analyte during sample clean-up for HPLC analyses. It was revealed that the ELISA methods can be applied easily to pesticide residue analysis in troublesome matrix such as Chinese chives.
Diagnostic use of recombinant Tha p 2 in the allergy to Thaumetopoea pityocampa.
Rodríguez-Mahillo, A I; Carballeda-Sangiao, N; Vega, J M; García-Ortiz, J C; Roques, A; Moneo, I; González-Muñoz, M
2015-10-01
Thaumetopoea pityocampa causes allergies and skin and ocular lesions. No commercial tools are currently available for the clinical diagnosis of this allergy. We aimed to develop an in vitro method for the diagnosis of this allergy to avoid patients undergoing in vivo tests with insect extracts. Recombinant Tha p 2 was produced and used in an ELISA validated with 15 allergic patients. Subsequently, 42 subjects recruited from a random sampling cross-sectional study were analysed. The ELISA sensitivity and specificity were 93.3% and 100%, respectively, for the allergic patients and 71.4% and 95.3%, respectively, for the epidemiological study. The positive ELISA results correlated with the skin prick test areas with the whole body and the setae extracts. Professional exposure and short latency of symptoms onset were risk factors for a positive result in the ELISA. In conclusion, our ELISA is very useful for T. pityocampa allergy diagnosis and for epidemiologic testing. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Antibody response to experimental Salmonella typhimurium infection in chickens measured by ELISA.
Hassan, J O; Barrow, P A; Mockett, A P; Mcleod, S
1990-05-26
An indirect ELISA has been developed to detect Salmonella typhimurium antibodies in chicken sera, using whole bacterial cell protein, flagellar protein or lipopolysaccharide as antigens. In experimental infections high concentrations of S typhimurium-specific IgG persisted after the faecal excretion of S typhimurium had ceased, whereas the specific IgM response was transitory. Some uninfected chickens placed in contact with experimentally infected birds developed high IgG titres in the absence of detectable faecal excretion. Other S typhimurium strains, which varied in their invasive abilities, also induced high titres of IgG. The ELISA allowed chickens infected experimentally with S typhimurium to be differentiated from chickens infected with 10 other serotypes, including S enteritidis. The use of whole blood in place of serum in the ELISA reduced the titres slightly. The storage of serum dried on to filter paper strips for four weeks produced little change in ELISA antibody titre, and the treatment of such strips with phenol or chloroform vapour had little or no effect on the antibody titre.
The Platelia Aspergillus ELISA in diagnosis of invasive pulmonary aspergilosis (IPA).
Siemann, M; Koch-Dörfler, M
2001-01-01
The sensitivity of a sandwich enzyme-linked immunosorbent assay (ELISA) for detecting Aspergillus galactomannan was evaluated with 66 serum samples and 113 specimens of the respiratory tract obtained from 52 patients with pulmonary diseases. The patients were divided into five groups: proven invasive pulmonary aspergillosis (IPA) (five patients), probable IPA (seven patients), Aspergillus colonization (eight patients) or unlikely Aspergillus infection (27 patients). Another five patients with doubtful diagnostic test results are discussed in detail. The results of the Platelia Aspergillus ELISA (Sanofi Pasteur, Freiburg, Germany) in testing specimens of the respiratory tract were 90% sensitivity in proven (serum 38%), 60% in probable (serum 37%) and 71% in Aspergillus colonization (serum 0%). Furthermore, 85% of the Aspergillus spp. from positive cultures of specimens of the respiratory tract were also detected in the ELISA. A total of 57% of the culture negative specimens of patients with a least one positive culture or proven aspergillosis in a series of specimens were positive in the ELISA.
Dombrowski, T.R.; Thurman, E.M.; Mohrman, G.B.
1996-01-01
A commercially available enzyme-linked immunosorbent assay (ELISA) plate kit for screening of cyclodiene insecticides (aldrin, chlordane, dieldrin, endosulfan, endrin, and heptachlor) was evaluated for sensitivity, cross reactivity, and overall performance using groundwater samples from a contaminated site. Ground-water contaminants included several pesticide compounds and their manufacturing byproducts, as well as many other organic and inorganic compounds. Cross-reactivity studies were carried out for the cyclodiene compounds, and results were compared to those listed by the manufacturer. Data obtained were used to evaluate the sensitivity of the ELISA kit to the cyclodiene compounds in ground water samples with a contaminated matrix. The method quantitation limit for the ELISA kit was 15 ??g/L (as chlordane). Of the 56 ground-water samples analyzed using the ELISA plate kits, more than 85% showed cyclodiene insecticide contamination. The ELISA kit showed excellent potential as a screening tool for sites with suspected groundwater contamination by insecticides.
Lower, K S; Medleau, L M; Hnilica, K; Bigler, B
2001-12-01
Canine scabies is a challenging disease to diagnose because sarcoptic mites are hard to find on skin scrapings. The purpose of this study was to evaluate a serologic enzyme-linked immunosorbent assay (ELISA) as an aid in the diagnosis of canine scabies. In addition, serum samples were obtained post treatment to determine the duration and persistence of circulating scabies antibodies after resolution of natural infection. Nineteen dogs diagnosed with sarcoptic mange and 38 control dogs were tested. Sixteen scabies-infested dogs showed positive pretreatment ELISA results (84.2% sensitivity). Thirty-four control dogs showed negative ELISA results (89.5% specificity). In the 11 scabies dogs from which multiple post treatment serum samples were obtained, detectable antibodies were not present 1 month after treatment in four cases, but were present for 1-4.5 months post treatment in seven dogs. Our results suggest that this scabies ELISA test is useful in the diagnosis of canine scabies.
Singha, Harisankar; Malik, Praveen; Goyal, Sachin K; Khurana, Sandip K; Mukhopadhyay, Chiranjay; Eshwara, Vandana K; Singh, Raj K
2014-01-01
To express truncated TssB protein of Burkholderia mallei and to evaluate its diagnostic efficacy for serological detection of glanders among equines. In an attempt to develop recombinant protein based enzyme-linked immunosorbent assay (ELISA), N-terminal 200 amino acid sequences of B. mallei TssB protein-a type 6 secretory effector protein--were expressed in prokaryotic expression system. Diagnostic potential of recombinant TssB protein was evaluated in indirect ELISA using a panel of glanders positive (n = 49), negative (n = 30), and field serum samples (n = 1811). Cross-reactivity of the assay was assessed with equine disease control serum and human melioidosis positive serum. In comparison to CFT, diagnostic sensitivity and specificity of ELISA were 99.7% and 100%, respectively. The indirect ELISA method using the truncated TssB offered safer and more rapid and efficient means of serodiagnosis of glanders in equines. These data highlight the use of TssB as potential diagnostic antigen for serological diagnosis of glanders.
Li, Ya; Li, Yanqing; Zhao, Junli; Zheng, Xiaojing; Mao, Qinwen; Xia, Haibin
2016-12-01
Enzyme-linked immunosorbent assay (ELISA) has been one of the main methods for detecting an antigen in an aqueous sample for more than four decades. Nowadays, one of the biggest concerns for ELISA is still how to improve the sensitivity of the assay, and the luciferase-luciferin reaction system has been noticed as a new detection method with high sensitivity. In this study, a luciferin-luciferase reaction system was used as the detection method for a sandwich ELISA system. It was shown that this new system led to an increase in the detection sensitivity of at least two times when compared with the traditional horseradish peroxidase (HRP) detection method. Lastly, the serum levels of the human extracellular matrix 1 protein of breast cancer patients were determined by the new system, which were overall similar to the HRP chemiluminescent system. Furthermore, this new luciferase reporter can be implemented into other ELISA systems for the purpose of increasing the assay sensitivity.
Nielsen, Martin K; Vidyashankar, Anand N; Bellaw, Jennifer; Gravatte, Holli S; Cao, Xin; Rubinson, Emily F; Reinemeyer, Craig R
2015-02-01
Strongylus vulgaris is the most pathogenic helminth parasite of horses, causing verminous endarteritis with thromboembolism and infarction. A serum enzyme-linked immunosorbent assay (ELISA) has been validated for detection of antibodies to an antigen produced by migrating larvae of this parasite. The aim was to evaluate ELISA responses to anthelmintic treatment in cohorts of naturally infected horses. Fifteen healthy horses harboring patent S. vulgaris infections were turned out for communal grazing in May 2013 (day 0). On day 55, horses were ranked according to ELISA titers and randomly allocated to the following three groups: no treatment followed by placebo pellets daily; ivermectin on day 60 followed by placebo pellets daily; or ivermectin on day 60 followed by daily pyrantel tartrate. Fecal and serum samples were collected at ∼28-day intervals until study termination on day 231. Increased ELISA values were observed for the first 53 days following ivermectin treatment. Titers were significantly reduced 80 days after ivermectin treatment. Horses receiving daily pyrantel tartrate maintained lower ELISA values from 137 days post ivermectin treatment until trial termination. These results illustrate that a positive ELISA result is indicative of either current or prior exposure to larval S. vulgaris infection within the previous 5 months.
Liu, Ying; Chen, Yu-qing; Zhou, Jing-jing; Han, Jia; Liang, Yu; Li, Xue-ying; Zhang, Hong
2012-04-18
To establish a method of enzyme-linked immunosorbent assay (ELISA) to measure urinary uromodulin and explore the urinary uromudulin level in IgA nephropathy. The rabbit anti-human uromodulin polyclonal antibodies were coated on plates to capture uromodulin and the mouse anti-human uromodulin monoclonal antibody was used as detecting antibody to set up ELISA procedure. The precision and repeatability of this ELISA method were evaluated, and then this method was compared with the commercialized Tamm-Horsfall Glycoprotein ELISA Kit by examining urinary uromodulin levels in 55 individuals. Finally, the urinary uromodulin level in 166 IgA nephropathy patients were detected as well as 48 normal controls with this established method. The detecting range of uromodulin was 0.78-12.5 μg/L by this method. The coefficient of variation within-run was 7.5%, and between-run of coefficient of variation was 7.9%. Correlation of this method and comercialized kit was good (r=0.615, P<0.001). The urinary uromodulin/urinary creatinine ratio in IgA nephropathy was significantly lower than that in normal controls. The established ELISA method is sensitive and repeatable, and can be used in further studies.
Garber, Eric A E; Thole, Joseph
2015-06-11
The utility of microwave irradiation to accelerate the onset of equilibrium and improve ELISA performance was examined using ELISAs for the detection of the plant toxin ricin and gliadin. The ricin ELISA normally requires several one hour incubations at 37 °C, a total assay time of approximately five hours, and employs a complex buffer containing PBS, Tween-20®, and non-fat milk. Different energy levels and pulse designs were compared to the use of abbreviated incubation times at 37 °C for the detection of ricin in food. The use of microwave irradiation had no significant advantage over the application of heat using an oven incubator and performed worse with some foods. In contrast, a gliadin ELISA that relied on 30 min incubation steps at room temperature and a salt-based buffer performed better upon irradiation but also displayed improvement upon incubating the microtiter plate at 37 °C. Whether microwave irradiation was advantageous compared to incubation in an oven was inconclusive. However, by abbreviating the incubation time of the ricin ELISA, it was possible to cut the assay time to less than 2 hours and still display LOD values < 10 ppb and recoveries of 78%-98%.
Development and Validation of Sandwich ELISA Microarrays with Minimal Assay Interference
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gonzalez, Rachel M.; Servoss, Shannon; Crowley, Sheila A.
Sandwich enzyme-linked immunosorbent assay (ELISA) microarrays are emerging as a strong candidate platform for multiplex biomarker analysis because of the ELISA’s ability to quantitatively measure rare proteins in complex biological fluids. Advantages of this platform are high-throughput potential, assay sensitivity and stringency, and the similarity to the standard ELISA test, which facilitates assay transfer from a research setting to a clinical laboratory. However, a major concern with the multiplexing of ELISAs is maintaining high assay specificity. In this study, we systematically determine the amount of assay interference and noise contributed by individual components of the multiplexed 24-assay system. We findmore » that non-specific reagent cross-reactivity problems are relatively rare. We did identify the presence of contaminant antigens in a “purified antigen”. We tested the validated ELISA microarray chip using paired serum samples that had been collected from four women at a 6-month interval. This analysis demonstrated that protein levels typically vary much more between individuals then within an individual over time, a result which suggests that longitudinal studies may be useful in controlling for biomarker variability across a population. Overall, this research demonstrates the importance of a stringent screening protocol and the value of optimizing the antibody and antigen concentrations when designing chips for ELISA microarrays.« less
Hamidi, Ahd; Kreeftenberg, Hans
2014-01-01
Quality control of Hemophilus Influenzae type b (Hib) conjugate vaccines is mainly dependent on physicochemical methods. Overcoming sample matrix interference when using physicochemical tests is very challenging, these tests are therefore only used to test purified samples of polysaccharide, protein, bulk conjugate, and final product. For successful development of a Hib conjugate vaccine, several ELISA (enzyme-linked immunosorbent assay) methods were needed as an additional tool to enable testing of in process (IP) samples. In this paper, three of the ELISA's that have been very valuable during the process development, implementation and scaling up are highlighted. The PRP-ELISA, was a very efficient tool in testing in process (IP) samples generated during the development of the cultivation and purification process of the Hib-polysaccharide. The antigenicity ELISA, was used to confirm the covalent linkage of PRP and TTd in the conjugate. The anti-PRP IgG ELISA was developed as part of the immunogenicity test, used to demonstrate the ability of the Hib conjugate vaccine to elicit a T-cell dependent immune response in mice. ELISA methods are relatively cheap and easy to implement and therefore very useful during the development of polysaccharide conjugate vaccines.
Bomfim, Maria Rosa Quaresma; Ko, Albert; Koury, Matilde Cota
2005-08-10
The recombinant leptospiral protein LipL32 was evaluated for use in the diagnosis of bovine leptospirosis by enzyme-linked immunosorbent assay (rLipL32 IgG ELISA). The microscopic agglutination test (MAT) of 150 serum samples from cattle suspected of leptospirosis showed that 125 (83.3%) samples had positive reciprocal agglutination titres, which ranged from 100 to 1600. The highest titres were observed for the serovars Hardjoprajitno and Bratislava. In the rLipL32 IgG ELISA, 83.3% of the samples were positive. The sensitivity of IgG ELISA for 125 bovine sera, which had MAT titres of greater than or equal to 100, was 100%. ELISA showed a specificity of 100% with 58 bovine sera, which were negative at a 1:50 dilution in the MAT for Leptospira interrogans serovars. When analytical specificity of the IgG ELISA was evaluted using 60 bovine serum samples from animals showing serum antibodies to other pathogens that cause abortion in cattle, such as Babesia sp., Anaplasma sp. and Brucella sp. and no cross-reaction was observed. The recombinant LipL32 IgG ELISA can be an alternative to the MAT for diagnosis of leptospiral infection in cattle.
Mart'ianov, Andrey A; Dzantiev, Boris B; Zherdev, Anatoly V; Eremin, Sergei A; Cespedes, Raquel; Petrovic, Mira; Barcelo, Damia
2005-01-30
Immunoenzyme assay (ELISA) is proposed and characterized for determination of alkylphenol ethoxylates, a primary class of manufactured non-ionic surfactants. The assay is based on the obtained polyclonal antibodies against nonylphenol (NP), the main stable intermediate of the decomposition of nonylphenol ethoxylates. A mixture of non-modified branched isomers of NP was applied as hapten coupled to protein carriers by Mannich reaction with the use of formaldehyde. The proposed ELISA format is based on immobilized NP-(soybean trypsin inhibitor) conjugate as a competitor of antigen molecules contained in the tested sample for binding with specific antibodies indirectly labeled via an anti-species immunoperoxidase conjugate. The developed ELISA allows to reveal NP with the limit of detection about 10ngml(-1) and NP-related compounds such as octylphenol, alkylphenoletoxylates, alkylphenolcarboxylates and their halogenated derivatives. The ELISA was applied for assaying polluted water samples, namely influents and effluents from different wastewater treatment plants (WWTP) and tap water. ELISA and chromatographic data demonstrate good correlation (r = 0.94), while ELISA gives higher values. Due to endocrine disrupting and other toxic activities of some metabolites of alkylphenolic non-ionic surfactants, the developed assay may be effectively used in ecological monitoring and sanitary control.
Lee, Mei-Feng; Chen, Yen-Hsu; Hsu, Hui-Jine; Peng, Chien-Fang
2010-10-01
In this study, we designed a simple and rapid colorimetric detection method, a one-tube loop-mediated isothermal amplification (LAMP)-PCR-hybridization-restriction endonuclease-ELISA [one-tube LAMP-PCR-HY-RE-ELISA] system, to detect resistance to isoniazid, ethambutol and streptomycin in strains of Mycobacterium tuberculosis isolated from clinical specimens. The clinical performance of this method for detecting isoniazid-resistant, ethambutol-resistant and streptomycin-resistant isolates of M. tuberculosis showed 98.9%, 94.3% and 93.8%, respectively. This assay is rapid and convenient that can be performed within one working day. One-tube LAMP-PCR-HY-RE-ELISA system was designed based on hot spot point mutations in target drug-resistant genes, using LAMP-PCR, hybridization, digestion with restriction endonuclease and colorimetric method of ELISA. In this study, LAMP assay was used to amplify DNA from drug-resistant M. tuberculosis, and ELISA was used for colorimetrical determination. This assay will be a useful tool for rapid diagnosis of mutant codons in strains of M. tuberculosis for isoniazid at katG 315 and katG 463, ethambutol at embB 306 and embB 497, and streptomycin at rpsL 43. Crown Copyright © 2010. Published by Elsevier B.V. All rights reserved.
Tian, Zhancheng; Du, Xiaoyue; Du, Junzheng; Gao, Shandian; Yu, Ruiming; Hassan, Muhammad Adeel; Liu, Guangyuan; Luo, Jianxun; Yin, Hong
2018-06-01
Tropical theileriosis, caused by Theileria annulata, is distributed worldwide and causes great economic losses in dairy. The reliable diagnostic method is critical for prevention and control of the disease. In this study, a sporozoite and macroschizont gene 2 (spm2) protein from T. annulata was used to develop an indirect ELISA for tropical theileriosis. Specificity test showed that there were no cross-reactions with antibodies raised against other bovine piroplasm species using ELISA or western blotting. The specificity and sensitivity were 98.4% and 98.7%, respectively, with a threshold of 35.5% of the specific mean antibody rate (AbR). Furthermore, a total of 196 field sera samples collected from Xinjiang and Gansu provinces were detected by the spm2 ELISA and IFA. The results obtained with the spm2 ELISA and IFA in this study had the moderate agreement. The average positive rates of T. annulata sera samples detected in the present study were close to the prevalence of previous reports in these endemic areas. This indicated that the Spm2 ELISA could be used as a reliable diagnostic tool for serological survey of T. annulata infection in areas where Theileria parva is not present. Copyright © 2018 Elsevier B.V. All rights reserved.
Sapozhnikova, Yelena; Simons, Tawana; Lehotay, Steven J
2015-05-13
A simple, fast, and cost-effective sample preparation method, previously developed and validated for the analysis of organic contaminants in fish using low-pressure gas chromatography-tandem mass spectrometry (LPGC-MS/MS), was evaluated for the analysis of polybrominated diphenyl ethers (PBDEs) and dichlorodiphenyltrichloroethane (DDT) pesticides using enzyme-linked immunosorbent assay (ELISA). The sample preparation technique was based on the quick, easy, cheap, rugged, effective, and safe (QuEChERS) approach with filter-vial dispersive solid phase extraction (d-SPE). Incurred PBDEs and DDTs were analyzed in three types of fish with 3-10% lipid content: Pacific croaker, salmon, and National Institute of Standards and Technology (NIST) Standard Reference Material 1947 (Lake Michigan fish tissue). LPGC-MS/MS and ELISA results were in agreement: 108-111 and 65-82% accuracy ELISA versus LPGC-MS/MS results for PBDEs and DDTs, respectively. Similar detection limits were achieved for ELISA and LPGC-MS/MS. Matrix effects (MEs) were significant (e.g., -60%) for PBDE measurement in ELISA, but not a factor in the case of DDT pesticides. This study demonstrated that the sample preparation method can be adopted for semiquantitative screening analysis of fish samples by commercial kits for PBDEs and DDTs.
Angelidou, E; Kostoulas, P; Leontides, L
2014-02-01
We validated a commercial (Idexx Pourquier, Montpellier, France) serum and milk indirect ELISA that detects antibodies against Mycobacterium avium ssp. paratuberculosis (MAP) in Greek dairy goats. Each goat was sampled 4 times, starting from kidding and covering early, mid, and late lactation. A total of 1,268 paired milk (or colostrum) and serum samples were collected during the 7-mo lactation period. Bayesian latent class models, which allow for the continuous interpretation of test results, were used to derive the distribution of the serum and milk ELISA response for healthy and MAP-infected individuals at each lactation stage. Both serum and milk ELISA, in all lactation stages, had average and similar overall discriminatory ability as measured by the area under the curve (AUC). For each test, the smallest overlap between the distribution of the healthy and MAP-infected does was in late lactation. At this stage, the AUC was 0.89 (95% credible interval: 0.70; 0.98) and 0.92 (0.74; 0.99) for the milk and serum ELISA, respectively. Both tests had comparable sensitivities and specificities at the recommended cutoffs across lactation. Lowering the cutoffs led to an increase in sensitivity without serious loss in specificity. In conclusion, the milk ELISA was as accurate as the serum ELISA. Therefore, it could serve as the diagnostic tool of choice, especially during the implementation of MAP control programs that require frequent testing, because milk sampling is a noninvasive, rapid, and easy process. Copyright © 2014 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Koestel, Carole; Simonin, Céline; Belcher, Sandrine
2016-01-01
Abstract Since the early 2000s, labeling of potentially allergenic food components to protect people who suffer from food allergies is compulsory in numerous industrialized countries. In Europe, milk and egg components used during the winemaking process must be indicated on the label since July 1, 2012. Several ELISA procedures have been developed to detect allergenic residues in wines. However, the complexity of the wine matrix can inhibit the immunoenzymatic reaction. The aim of this study was to implement an ELISA assay for the detection of ovalbumin in red wines using commercially available antibodies. The specificity of the acquired antibodies and the absence of cross reactivity were assessed by immunoblotting and ELISA. An ELISA assay with a LOD of 14.2 μg/L and a LOQ of 56.4 μg/L of ovalbumin in aqueous solution was obtained. Differences in ELISA signals were observed when analyzing various fining agents, although reproducible conformation of the antigen could be reached for the comparison of ovalbumin and Ovicolle. The differences between samples in terms of pH could be leveled but the inhibition of the ELISA signal, positively correlated to the tannin content of the wines, could not be suppressed. Thus, standard curves of ovalbumin in several wines were obtained by relative quantification. The control steps and the difficulties encountered presented in this study should be considered by anybody working toward the development of ELISA assays for the detection of allergenic residues in complex food matrices. PMID:27356183
Memon, Atta Muhammad; Bhuyan, Anjuman Ara; Chen, Fangzhou; Guo, Xiaozhen; Menghwar, Harish; Zhu, Yinxing; Ku, Xugang; Chen, Shuhua; Li, Zhonghua; He, Qigai
2017-05-01
Porcine rotavirus-A (PoRVA) is one of the common causes of mild to severe dehydrating diarrhea, leading to losses in weaning and postweaning piglets. A rapid, highly specific, and sensitive antigen-capture enzyme-linked immunosorbent assay (AC-ELISA) was developed for detection of PoRVA, by using VP6 (a highly conserved and antigenic protein of group-A rotavirus)-directed rabbit polyclonal antibodies (capture antibody) and murine monoclonal antibodies (detector antibody). The detection limit of AC-ELISA was found to be equal to that of conventional reverse transcription-polymerase chain reaction (RT-PCR; about 10 2.5 TCID 50 /mL). For validation of the in-house AC-ELISA, 295 porcine fecal/diarrhea samples, collected from different provinces of China, were evaluated and compared with conventional RT-PCR and TaqMan RT-quantitative PCR (qPCR). The sensitivity and specificity of this in-house AC-ELISA relative to RT-qPCR were found to be 91.67% and 100%, respectively, with the strong agreement (kappa = 0.972) between these two techniques. Total detection rate with AC-ELISA, conventional RT-PCR, and RT-qPCR were found to be 11.2%, 11.5%, and 12.2%, respectively, without any statistical significant difference. Moreover, AC-ELISA failed to detect any cross-reactivity with porcine epidemic diarrhea virus, transmissible gastroenteritis virus, pseudorabies virus, and porcine circovirus-2. These results suggested that our developed method was rapid, highly specific, and sensitive, which may help in large-scale surveillance, timely detection, and preventive control of rotavirus infection in porcine farms.
Gaikwad, Seema; Sawant, Sandhya S.; Shastri, Jayanthi S.
2017-01-01
INTRODUCTION: Early diagnosis of dengue is important for appropriate clinical management and vector control. Different serological tests based on the principle of immunochromatography and enzyme-linked immunosorbent assay (ELISA) are commonly used for detection of antigen and antibodies of dengue virus. The performance of these tests depends on the sensitivity and specificity. Hence, the study was undertaken to compare nonstructural protein-1 (NS1) antigen detection by rapid and ELISA with real-time polymerase chain reaction (RT-PCR) for diagnosis of dengue. MATERIALS AND METHODS: Prospective laboratory study was carried out on sera samples (n = 200) from clinically suspected cases of dengue. The sera samples were subjected for NS1 antigen detection test by rapid test, NS1 ELISA, and RT-PCR. The results of rapid and ELISA tests were compared with real Time PCR. RESULTS: The sensitivity, specificity, positive, and negative predictive value of rapid dengue NS1 antigen test were 81.5%, 66.7%, 78.2%, and 71.1%, respectively whereas that of NS1 ELISA were 89.9%, 100%, 100%, and 94%, respectively. Concordance of Rapid NS1 and NS1 ELISA with PCR was 75.5% and 94%. DISCUSSION AND CONCLUSION: NS1 antigen ELISA can be implemented in diagnostic laboratories for diagnosis of dengue in the acute phase of illness. The test also has great potential value for use in epidemic situations, as it could facilitate the early screening of patients and limit disease expansion. PMID:28706387
Dosunmu, Adedoyin Owolabi; Akinbami, Akinsegun Abduljaleel; Ismail, Ayobami Kamal; Olaiya, Modupe Adebimpe; Uche, Ebele Ifeyinwa; Aile, Igbinoba Kingsley
2017-01-01
Blood transfusion practice emphasises safety, efficacy and appropriate use. These require cost-effective programme management. This study focused on the cost of screening for transfusion transmissible infections (TTI). This was a 1 year (2016) analysis of screening in a hospital-based transfusion centre. The cost of screening all blood donors by ELISA was compared to the cost of serial screening starting from rapid kit, taking into account, the estimated cost of blood bags prevented from discard after ELISA screening (attributable cost). The cost of voluntary donor drive plus cost of ELISA screening was compared with the present cost of screening. A total of 5591 donors were screened for HIV, hepatitis B and C using the rapid kit, 291 donors were deferred (5.2%). A total of 5300 units were further screened by ELISA. A total of 435 blood units (8.2%) were discarded due to TTI positivity. TTI positivity rate was 12.98%. Only 2.36% were voluntary donors and among these 9.1% were TTI positive. The attributable cost of serial screening was 55,653.5 USD while that of screening by ELISA only was 55,910 USD. The attributable cost of rapid screening for only hepatitis B and then ELISA was 53,313.9 USD taking into consideration that 187 blood units would be prevented from undue discard. This analysis demonstrated that with proper donor selection, rapid screening for hepatitis B virus only before ELISA screening is more cost-effective. This will also reduce the waiting time for donors and counselling if HIV positive.
Specificity of Toxocara ELISA in tropical populations.
Lynch, N R; Wilkes, L K; Hodgen, A N; Turner, K J
1988-05-01
The diagnosis of human infection by Toxocara canis relies heavily upon serological tests, the specificity of which can be inadequate in regions of endemic helminthiasis. When different population groups of tropical Venezuela were evaluated using ELISA based upon Toxocara excretory-secretory antigen (TcESA), solid-phase adsorption of the sera with extracts of a wide variety of non-homologous parasites revealed the existence of significant cross-reactivity. This was effectively and conveniently overcome when the test sera were incubated in the presence of the soluble parasite extracts in a competitive inhibition ELISA. The mean reduction of ELISA values caused by pre-adsorption of the sera tested was 32.2%, and that caused by competitive inhibition was 42.3%, the effects of these two procedures being strongly correlated (r = 0.83). The magnitude of the reduction was inversely proportional to the actual ELISA value (r = -0.55), and ranged from a mean of 68.0% in sera from apparently healthy individuals of medium-high socio-economic level, down to 28.1% in heavily parasitized Amazon indians. Ascaris showed the greatest degree of cross-reactivity in these tests, although under conditions of competitive inhibition even sera with high levels of antibody against this parasite could be negative in Toxocara ELISA. Western blotting revealed a major 81,400 D component that was shared between Ascaris and TcESA. Our results indicate that the competitive inhibition of cross-reactivity by soluble non-homologous parasite extracts provides a convenient and economical means of increasing the specificity of ELISA for the determination of the seroprevalence of toxocariasis in tropical populations.
Penicillinase-based enzyme-linked immunosorbent assay for the detection of plant viruses.
Sudarshana, M R; Reddy, D V
1989-10-01
A penicillinase (PNC)-based, enzyme-linked immunosorbent assay (ELISA) was standardized to detect maize mosaic virus (MMV) in sorghum leaf extracts, peanut mottle virus (PMV) in pea leaf extracts, and tomato spotted wilt virus (TSWV) in peanut leaf extracts. Rabbit Fc-specific antibodies were conjugated with PNC by a single step glutaraldehyde bridge. Among several indicators tested, bromothymol blue (BTB) was found suitable for measuring PNC activity under simulated conditions. Two reagents, starch-iodine complex (SIC) and a mixed pH indicator, containing bromocresol purple and BTB (2:1) used earlier for the PNC-based ELISA, were compared with BTB for utilization in the PNC-based ELISA. SIC gave a slightly higher virus titre than BTB or the mixed pH indicator, but it often gave nonspecific reactions. Sodium or potassium salts of penicillin-G at 0.5-1.0 mg/ml and BTB at 0.2 mg/ml were found to be suitable as substrate-indicator mixture for PNC-based ELISA. The sensitivity of the PNC system was comparable to those of the alkaline phosphatase (ALP) and horseradish peroxidase (HRP) systems in detecting MMV, PMV, and TSWV. The PNC conjugate could be used at a greater dilution than those of the ALP and HRP conjugates and the BTB substrate mixture was stable for at least 3 weeks at 4 degrees C. Penicillin is readily available in developing countries, and at a substantially lower cost than p-nitrophenyl phosphate, the commonly used substrate for ALP in the plate ELISA. Thus the PNC-based ELISA provides a less expensive means for assaying plant viruses by ELISA.
Gray, Lauren K; Crawford, P Cynda; Levy, Julie K; Dubovi, Edward J
2012-05-01
To compare 2 assays for use in the identification of dogs with a protective antibody titer (PAT) against canine parvovirus (CPV) and canine distemper virus (CDV). Prospective cross-sectional study. 431 dogs admitted to a municipal animal shelter in north central Florida. Blood samples were collected from dogs on the day of admission to the shelter. Serum was obtained, criterion-referenced assays were used to identify dogs that had PATs against CPV (titers ≥ 80; hemagglutination inhibition assay) and CDV (titers ≥ 32; virus neutralization assay), and results were compared with results of a semiquantitative ELISA and an immunofluorescence assay (IFA). For correct identification of dogs that had PATs against viruses, the ELISA had significantly higher specificity for CPV (98%) and CDV (95%) than did the IFA (82% and 70%, respectively) and had significantly lower sensitivity for CDV (88%) than did the IFA (97%); the sensitivity for CPV was similar (ELISA, 98%; IFA, 97%). Overall diagnostic accuracy was significantly greater with the ELISA than with the IFA. Predictive value of a positive result for PATs was significantly higher with the ELISA for CPV (99%) and CDV (93%) than with the IFA (92% and 71%, respectively). The ELISA had fewer false-positive results than did the IFA and could be performed on-site in shelters in < 1 hour. Accuracy and practicality of the ELISA may be useful for identifying the infection risk of dogs exposed during outbreaks attributable to CPV and CDV infections in shelters.
Derouin, F.; Garin, Y. J.; Buffard, C.; Berthelot, F.; Petithory, J. C.
1994-01-01
A collaborative study conducted by the French National Agency for Quality Control in Parasitology (CNQP) and various manufacturers of ELISA kits, represented by the Association of Laboratory Reagent Manufacturers (SFRL) compared the toxoplasmosis IgG antibody titres obtained with different ELISA-IgG kits and determined the relationships between the titres obtained by these techniques and the titre defined in international units (IU). Fifty-one serum samples with toxoplasmosis antibody titres ranging from 0 to 900 IU were tested in two successive studies with 16 ELISA-IgG kits. For the negative sera, false-positive reactions were observed with one kit. For the positive sera, the titres observed in ELISA were generally higher than those expressed in IU. Above 250 IU, the very wide variability of the titres found with the different ELISA kits renders any comparative analysis impossible. For titres below 250 IU, the results are sufficiently homogeneous to permit the use of regression analysis to study how the results for each ELISA kit compare with the mean results for the other kits. The slope of the line of regression shows a tendency to over-titration or under-titration compared with the results of the other manufacturers; the ordinate at the origin reflects the positivity threshold of the reaction and can be used to assess the risk of a lack of sensitivity (high threshold) or of specificity (threshold too low). On the whole, the trends revealed for a given manufacturer are constant from one study to the other. Within this range of titres, regression analysis also reveals the general tendency of ELISA kits to overestimate the titres by comparison with immunofluorescence.(ABSTRACT TRUNCATED AT 250 WORDS) PMID:8205645
2014-01-01
Background Toxoplasmosis, caused by the obligate intracellular parasite Toxoplasma gondii, is an important zoonotic disease worldwide. The precise detection of T. gondii infection in dogs has important public health significance. In this study, recombinant granule antigen proteins GRA1 and GRA7 were evaluated as potential diagnostic markers for T. gondii infection in dogs by an indirect enzyme-linked immunosorbent assay (ELISA). Results GRA1 and GRA7 were cloned and expressed in Escherichia coli, and the recombinant GRA1, GRA7- and Toxoplasma lysate antigen (TLA)-based ELISAs were developed and evaluated using the canine positive and negative serum samples for anti-T. gondii antibodies determined by modified agglutination test (MAT) and indirect fluorescent antibody test (IFAT), showing a seroprevalence of 15.1% by TLA- and GRA1-ELISA, and 15.8% by GRA7-ELISA, and no significant difference was observed (P > 0.05). When compared with the two reference assays, MAT and IFAT, the GRA7-ELISA showed the highest co-positivity and co-negativity rates. Receiver operating characteristic (ROC) analysis revealed a largest area under curve (AUC) of 0.973 (95% CI, 0.955 to 0.991), and a highest relative sensitivity (93.2%) and specificity (94.0%) for a cut-off value of 0.809 in GRA7-ELISA. Conclusions The results of the present study showed that GRA7-ELISA is highly sensitive and specific, and GRA7 is a potential serodiagnostic marker for the detection of T. gondii infection in dogs. PMID:25016474
Horner, Patrick J; Wills, Gillian S; Reynolds, Rosy; Johnson, Anne M; Muir, David A; Winston, Alan; Broadbent, Andrew J; Parker, David; McClure, Myra O
2013-08-01
To investigate what factors influence the detection of Chlamydia trachomatis antibody following genital tract infection. One hundred and sixty-four women with a previous history of C trachomatis infection contributed to an earlier report on the performance of chlamydia antibody ELISA assays. We undertook further analysis to explore how chlamydia antibody assay sensitivity changes with time since infection. Chlamydia antibody was detected in more women soon after the last detection of chlamydia at the lower genital tract than at later times. This holds true for all tests, but the Anilabsystems IgG EIA, Medac pELISA plus ELISA and the Savyon SeroCT-IgG ELISA were less sensitive than the pgp3 ELISA and the Anilabsystems microimmunofluorescence (MIF) assay at all time points except during current infection. Fall in seropositivity in women generally occurred in the early weeks and months following the last episode of chlamydia infection. There was no clear pattern of further reduction in seropositivity after 6 months. Multiple previous episodes were associated with increased seropositivity in the pgp3 assay (two or more vs one, OR 19, p<0.001) and other tests, but the effect was significantly smaller for the Anilabs, Medac and SeroCT MOMP peptide ELISAs, but not for the MIF assay. Chlamydia antibody detection decreases with time since infection and this is most apparent in the first 6 months. In women who have had more than one infection, antibody remained detectable longer for all tests, but this was more marked for the pgp3 ELISA and MIF assay.
Ponterio, Eleonora; Di Bartolo, Ilaria; Orrù, Ginevra; Liciardi, Manuel; Ostanello, Fabio; Ruggeri, Franco Maria
2014-06-16
The hepatitis E virus (HEV) has been detected in both humans and animals, particularly pigs, worldwide. Several evidences, including human infection following consumption of raw contaminated meat, suggest a zoonotic transmission of HEV. In Italy, large circulation of genotype 3 HEV has been reported in swine, and recent studies have confirmed the involvement of this genotype in autochthonous human cases. In this study 111 sera collected from healthy pigs in two Italian regions were tested for anti-HEV IgG antibodies. For specific HEV antibody detection in swine, we developed ELISA and Western blotting methods, using a truncated capsid (ORF2) protein lacking the first 111 amino acids of a swine HEV genotype 3 strain. The ORF2-based ELISA revealed anti-HEV antibodies in 104 out of 111 pigs compared with 102 detected with a commercial ELISA kit. A lower number of sera reacted with the recombinant ORF2 protein in a Western blotting format (81/111). Using a Latent class analysis (LCA), the estimated sensitivities for ELISA-ORF2 and ELISA-kit tests were 0.961 and 0.936, respectively, whereas specificities were 0.599 and 0.475. The estimated sensitivity of Western blotting was 0.775, and the specificity was 0.944. The overall results confirm the high prevalence of HEV seropositive healthy pigs in Italy. Through comparisons with a commercial ELISA test, the swine genotype 3 HEV antigen produced in this study was proven suitable to detect anti-HEV antibodies in pig sera by both ELISA and Western Blotting.
Quinn, Andrea M; Williams, Allison R; Sivilli, Teresa I; Raison, Charles L; Pace, Thaddeus W W
2018-03-13
Circulating concentrations of interleukin (IL)-6, an inflammatory biomarker widely assessed in humans to study the inflammatory response to acute psychological stress, have for decades been quantified using enzyme-linked immunosorbent assay (ELISA). However, biobehavioral researchers are increasingly using cytokine multiplex assays instead of ELISA to measure IL-6 and other cytokines. Despite this trend, multiplex assays have not been directly compared to ELISA for their ability to detect subtle stress-induced changes of IL-6. Here, we tested the prediction that a high-sensitivity multiplex assay (human Magnetic Luminex Performance Assay, R&D Systems, Minneapolis, MN) would detect changes in IL-6 as a result of acute stress challenge in a manner comparable to high-sensitivity ELISA. Blood was collected from 12 healthy adults immediately before and then 90 and 210 min after the start of the Trier Social Stress Test (TSST), an acute laboratory psychosocial stress challenge. In addition to quantifying IL-6 concentrations in plasma with both multiplex and ELISA, we also assessed concentrations of tumor necrosis factor-alpha, IL-8, IL-10, IL-5, and IL-2 with multiplex. The multiplex detected IL-6 in all samples. Concentrations strongly correlated with values determined by ELISA across all samples (r = 0.941, p < .001) as well as among samples collected at individual TSST time points. IL-6 responses to the TSST (i.e. area under the curve) captured by multiplex and ELISA were also strongly correlated (r s = 0.937, p < .001). While other cytokines were detected by multiplex, none changed as a result of TSST challenge at time points examined. These results suggest high-sensitivity magnetic multiplex assay is able to detect changes in plasma concentrations of IL-6 as a result of acute stress in humans.
Maia, Zuinara; Lírio, Monique; Mistro, Sóstenes; Mendes, Carlos Maurício Cardeal; Mehta, Sanjay R.; Badaro, Roberto
2012-01-01
Background The rK39 recombinant protein is derived from a specific antigen produced by the Leishmania donovani complex, and has been used in the last two decades for the serodiagnosis of visceral leishmaniasis. We present here a systematic review and meta-analysis of studies evaluating serologic assays to diagnose visceral leishmaniasis to determine the accuracy of rK39 antigen in comparison to the use of other antigen preparations. Methodology/Principal Findings A systematic review with meta-analysis of the literature was performed to compare the rK39 strip-test and ELISA formats against serological tests using promastigote antigens derived from whole or soluble parasites for Direct Aglutination Test (DAT), Indirect Immunofluorescence test (IFAT) and ELISA with a promastigote antigen preparation (p-ELISA). Gold standard diagnosis was defined by the demonstration of amastigotes on hematological specimens. A database search was performed on Medline, Lilacs, Scopus, Isi Web of Science, and Cochrane Library. Quality of data was assessed using the QUADAS questionnaire. A search of the electronic databases found 352 papers of which only 14 fulfilled the selection criteria. Three evaluated the rK39 ELISA, while 13 evaluated the rK39 immunochromatographic strip test. The summarized sensitivity for the rK39-ELISA was 92% followed by IFAT 88% and p-ELISA 87%. The summarized specificity for the three diagnostic tests was 81%, 90%, and 77%. Studies comparing the rK39 strip test with DAT found a similar sensitivity of 94%, although the DAT had a slightly higher specificity. The rK39 strip test was more sensitive and specific than the IFAT and p-ELISA. We did not detect any difference in the sensitivity and specificity between strips produced by different manufacturers. Conclusions The rK39 protein used either in a strip test or in an ELISA, and the DAT are the best choices for implementation of rapid, easy and efficient test for serodiagnosis of VL. PMID:22303488
Maia, Zuinara; Lírio, Monique; Mistro, Sóstenes; Mendes, Carlos Maurício Cardeal; Mehta, Sanjay R; Badaro, Roberto
2012-01-01
The rK39 recombinant protein is derived from a specific antigen produced by the Leishmania donovani complex, and has been used in the last two decades for the serodiagnosis of visceral leishmaniasis. We present here a systematic review and meta-analysis of studies evaluating serologic assays to diagnose visceral leishmaniasis to determine the accuracy of rK39 antigen in comparison to the use of other antigen preparations. A systematic review with meta-analysis of the literature was performed to compare the rK39 strip-test and ELISA formats against serological tests using promastigote antigens derived from whole or soluble parasites for Direct Aglutination Test (DAT), Indirect Immunofluorescence test (IFAT) and ELISA with a promastigote antigen preparation (p-ELISA). Gold standard diagnosis was defined by the demonstration of amastigotes on hematological specimens. A database search was performed on Medline, Lilacs, Scopus, Isi Web of Science, and Cochrane Library. Quality of data was assessed using the QUADAS questionnaire. A search of the electronic databases found 352 papers of which only 14 fulfilled the selection criteria. Three evaluated the rK39 ELISA, while 13 evaluated the rK39 immunochromatographic strip test. The summarized sensitivity for the rK39-ELISA was 92% followed by IFAT 88% and p-ELISA 87%. The summarized specificity for the three diagnostic tests was 81%, 90%, and 77%. Studies comparing the rK39 strip test with DAT found a similar sensitivity of 94%, although the DAT had a slightly higher specificity. The rK39 strip test was more sensitive and specific than the IFAT and p-ELISA. We did not detect any difference in the sensitivity and specificity between strips produced by different manufacturers. The rK39 protein used either in a strip test or in an ELISA, and the DAT are the best choices for implementation of rapid, easy and efficient test for serodiagnosis of VL.
Schuster, Isolde; Mertens, Marc; Köllner, Bernd; Korytář, Tomáš; Keller, Markus; Hammerschmidt, Bärbel; Müller, Thomas; Tordo, Noël; Marianneau, Philippe; Mroz, Claudia; Rissmann, Melanie; Stroh, Eileen; Dähnert, Lisa; Hammerschmidt, Felicitas; Ulrich, Rainer G; Groschup, Martin H
2016-10-01
Crimean-Congo hemorrhagic fever virus (CCHFV) circulates in many countries of Asia, Africa, and Europe. CCHFV can cause a severe hemorrhagic fever in humans with case-fatality rates of up to 80%. CCHF is considered to be one of the major emerging diseases spreading to and within Europe. Ticks of the genus Hyalomma function as vector as well as natural reservoir of CCHFV. Ticks feed on various domestic animals (e.g. cattle, sheep, goats) and on wildlife (e.g. hares, hedgehogs). Those animal species play an important role in the life cycle of the ticks as well as in amplification of CCHFV. Here we present a competitive ELISA (cELISA) for the species-independent detection of CCHFV-specific antibodies. For this purpose nucleocapsid (N) protein specific monoclonal antibodies (mAbs) were generated against an Escherichia coli (E. coli) expressed CCHFV N-protein. Thirty-three mAbs reacted with homologous and heterologous recombinant CCHFV antigens in ELISA and Western blot test and 20 of those 33 mAbs reacted additionally in an immunofluorescence assay with eukaryotic cells expressing the N-protein. Ten mAbs were further characterized in a prototype of the cELISA and nine of them competed with positive control sera of bovine origin. The cELISA was established by using the mAb with the strongest competition. For the validation, 833 sera from 12 animal species and from humans were used. The diagnostic sensitivity and specificity of the cELISA was determined to be 95% and 99%, respectively, and 2% of the sera gave inconclusive results. This cELISA offers the possibility for future large-scale screening approaches in various animal species to evaluate their susceptibility to CCHFV infection and to identify and monitor the occurrence of CCHFV. Copyright © 2016 Elsevier B.V. All rights reserved.
Zwerink, M; Zomer, T P; van Kooten, B; Blaauw, G; van Bemmel, T; van Hees, B C; Vermeeren, Y M; Landman, G W
2018-03-01
A two-step testing strategy is recommended in serological testing for Lyme borreliosis; positive and indeterminate enzyme-linked immunosorbent assay (ELISA) results are confirmed with immunoblots. Several ELISAs quantify the concentration of antibodies tested, however, no recommendation exists for an upper cut-off value at which an IgG ELISA is sufficient and the immunoblot can be omitted. The study objective was to determine at which IgG antibody level an immunoblot does not have any additional predictive value compared to ELISA results. Data of adult patients who visited a tertiary Lyme centre between 2008 and 2014 were analysed. Both an ELISA (Enzygnost Lyme link VlsE IgG) and immunoblot (recomLine blot Borrelia) were performed. Clinical data were extracted from the patient's digital medical record. Positive predictive values (PPVs) for either previous or active infection with Borrelia burgdorferi s.l. were calculated for different cut-off ELISA IgG antibody levels where the immunoblot was regarded as reference test. In total, 1454 patients were included. According to the two-step test strategy, 486 (33%), 69 (5%) and 899 (62%) patients had positive, indeterminate and negative Borrelia IgG serology, respectively. At IgG levels of 500 IU/ml and higher, all immunoblots were positive, resulting in a 100% PPV (95% CI: 97.0-100). At IgG levels of 200 IU/ml and higher, the PPV was 99.3% (95% CI: 97.4-99.8). In conclusion, at IgG levels of 200 IU/ml and higher, an ELISA was sufficient to detect antibodies to Borrelia burgdorferi s.l. At those IgG levels, a confirmatory immunoblot may be omitted in patients referred to a tertiary Lyme centre. Before these results can be implemented in routine diagnosis of Lyme borreliosis, confirmation of the results is necessary in other patient populations and using other quantitative ELISAs and immunoblots. Copyright © 2017 Elsevier GmbH. All rights reserved.
Carvalho, Fernando R; Silva, Deise A O; Cunha-Júnior, Jair P; Souza, Maria A; Oliveira, Taísa C; Béla, Samantha R; Faria, Gabriele G; Lopes, Carolina S; Mineo, José R
2008-08-01
The present study aimed to evaluate the performance of three monoclonal antibodies (MAbs) in reverse enzyme-linked immunosorbent assays (ELISAs) for detecting immunoglobulin G (IgG), IgM, and IgA antibodies against Toxoplasma gondii in 175 serum samples from patients at different stages of T. gondii infection, as defined by both serological and clinical criteria, as follows: recent (n = 45), transient (n = 40), and chronic (n = 55) infection as well as seronegative subjects (n = 35). The results were compared with those obtained by indirect ELISA using soluble Toxoplasma total antigen (STAg). Our data demonstrated that MAb A3A4 recognizes a conformational epitope in SAG1-related-sequence (SRS) antigens, while A4D12 and 1B8 recognize linear epitopes defined as SAG2A surface antigen and p97 cytoplasmatic antigen, respectively. Reverse ELISA for IgG with A3A4 or A4D12 MAbs was highly correlated with indirect ELISA for anti-STAg IgG, whereas only A4D12 reverse ELISA showed high correlation with indirect ELISA for IgM and IgA isotypes. To our knowledge, this is the first report analyzing the performance of a reverse ELISA for simultaneous detection of IgG, IgM, and IgA isotypes active toward native SAG2A, SRS, and p97 molecules from STAg, using a panel of human sera from patients with recent and chronic toxoplasmosis. Thus, reverse ELISA based on the capture of native SAG2A and SRS antigens of STAg by MAbs could be an additional approach for strengthening the helpfulness of serological tests assessing the stage of infection, particularly in combination with highly sensitive and specific assays that are frequently used nowadays for diagnosis of toxoplasmosis during pregnancy or congenital infection in newborns.
Blacksell, Stuart D.; Tanganuchitcharnchai, Ampai; Jintaworn, Suthatip; Kantipong, Pacharee; Richards, Allen L.; Day, Nicholas P. J.
2016-01-01
The enzyme-linked immunosorbent assay (ELISA) has been proposed as an alternative serologic diagnostic test to the indirect immunofluorescence assay (IFA) for scrub typhus. Here, we systematically determine the optimal sample dilution and cutoff optical density (OD) and estimate the accuracy of IgM ELISA using Bayesian latent class models (LCMs). Data from 135 patients with undifferentiated fever were reevaluated using Bayesian LCMs. Every patient was evaluated for the presence of an eschar and tested with a blood culture for Orientia tsutsugamushi, three different PCR assays, and an IgM IFA. The IgM ELISA was performed for every sample at sample dilutions from 1:100 to 1:102,400 using crude whole-cell antigens of the Karp, Kato, and Gilliam strains of O. tsutsugamushi developed by the Naval Medical Research Center. We used Bayesian LCMs to generate unbiased receiver operating characteristic curves and found that the sample dilution of 1:400 was optimal for the IgM ELISA. With the optimal cutoff OD of 1.474 at a sample dilution of 1:400, the IgM ELISA had a sensitivity of 85.7% (95% credible interval [CrI], 77.4% to 86.7%) and a specificity of 98.1% (95% CrI, 97.2% to 100%) using paired samples. For the ELISA, the OD could be determined objectively and quickly, in contrast to the reading of IFA slides, which was both subjective and labor-intensive. The IgM ELISA for scrub typhus has high diagnostic accuracy and is less subjective than the IgM IFA. We suggest that the IgM ELISA may be used as an alternative reference test to the IgM IFA for the serological diagnosis of scrub typhus. PMID:27008880
Munson, A. Douglas; Elliott, Diane G.; Johnson, Keith
2010-01-01
From the mid-1980s through the early 1990s, outbreaks of bacterial kidney disease (BKD) caused by Renibacterium salmoninarum continued in Chinook salmon Oncorhynchus tshawytscha in Idaho Department of Fish and Game (IDFG) hatcheries despite the use of three control methods: (1) injection of returning adult fish with erythromycin to reduce prespawning BKD mortality and limit vertical transmission of R. salmoninarum, (2) topical disinfection of green eggs with iodophor, and (3) prophylactic treatments of juvenile fish with erythromycin-medicated feed. In addition, programs to manage BKD through measurement of R. salmoninarum antigen levels in kidney tissues from spawning female Chinook salmon by an enzyme-linked immunosorbent assay (ELISA) were tested over 13–15 brood years at three IDFG hatcheries. The ELISA results were used for either (1) segregated rearing of progeny from females with high ELISA optical density (OD) values (usually ≥0.25), which are indicative of high R. salmoninarum antigen levels, or (2) culling of eggs from females with high ELISA OD values. The ELISA-based culling program had the most profound positive effects on the study populations. Mortality of juvenile fish during rearing was significantly lower at each hatchery for brood years derived from culling compared with brood years for which culling was not practiced. The prevalence of R. salmoninarum in juvenile fish, as evidenced by detection of the bacterium in kidney smears by the direct fluorescent antibody test, also decreased significantly at each hatchery. In addition, the proportions of returning adult females with kidney ELISA OD values of 0.25 or more decreased 56–85% for fish reared in brood years during which culling was practiced, whereas the proportions of ELISA-negative adults increased 55–58%. This management strategy may allow IDFG Chinook salmon hatcheries to reduce or eliminate prophylactic erythromycin-medicated feed treatments. We recommend using ELISA-based management of BKD in Chinook salmon hatcheries where it is a concern.
Hermann, Laura L; Thaisomboonsuk, Butsaya; Poolpanichupatam, Yongyuth; Jarman, Richard G; Kalayanarooj, Siripen; Nisalak, Ananda; Yoon, In-Kyu; Fernandez, Stefan
2014-10-01
Currently, no dengue NS1 detection kit has regulatory approval for the diagnosis of acute dengue fever. Here we report the sensitivity and specificity of the InBios DEN Detect NS1 ELISA using a panel of well characterized human acute fever serum specimens. The InBios DENV Detect NS1 ELISA was tested using a panel composed of 334 serum specimens collected from acute febrile patients seeking care in a Bangkok hospital in 2010 and 2011. Of these patients, 314 were found to have acute dengue by either RT-PCR and/or anti-dengue IgM/IgG ELISA. Alongside the InBios NS1 ELISA kit, we compared the performance characteristics of the BioRad Platelia NS1 antigen kit. The InBios NS1 ELISA Ag kit had a higher overall sensitivity (86% vs 72.8%) but equal specificity (100%) compared to the BioRad Platelia kit. The serological status of the patient significantly influenced the outcome. In primary infections, the InBios NS1 kit demonstrated a higher sensitivity (98.8%) than in secondary infections (83.5%). We found significant variation in the sensitivity of the InBios NS1 ELISA kit depending on the serotype of the dengue virus and also found decreasing sensitivity the longer after the onset of illness, showing 100% sensitivity early during illness, but dropping below 50% by Day 7. The InBios NS1 ELISA kit demonstrated high accuracy when compared to the initial clinical diagnosis with greater than 85% agreement when patients were clinically diagnosed with dengue illness. Results presented here suggest the accurate detection of circulating dengue NS1 by the InBios DENV Detect NS1 ELISA can provide clinicians with a useful tool for diagnosis of early dengue infections.
Sonmez, Cemile; Coplu, Nilay; Gozalan, Aysegul; Akin, Lutfu; Esen, Berrin
2017-06-01
Detection of anti-tetanus antibody levels is necessary for both determination of the immune status of individuals and also for planning preventive measures. ELISA is the preferred test among in vitro tests however it can be affected by the cross reacting antibodies. A previously developed in-house ELISA test was found not reliable for the antibody levels ≤1.0IU/ml. A new method was developed to detect low antibody levels correctly. The aim of the present study was to compare the results of the newly developed in-house biotin-avidin tetanus IgG ELISA test with the in vivo mouse neutralization test, for the antibody levels ≤1.0IU/ml. A total of 54 serum samples with the antibody levels of three different levels, =0.01IU/ml, 0.01-0.1IU/ml, 0.1-1IU/ml, which were detected by in vivo mouse neutralization test were studied by the newly developed in-house biotin-avidin tetanus IgG ELISA test. Test was validated by using five different concentrations (0.01IU/ml, 0.06IU/ml, 0.2IU/ml, 0.5IU/ml, 1.0IU/ml). A statistically significant correlation (r 2 =0.9967 p=0,001) between in vivo mouse neutralization test and in-house biotin-avidin tetanus IgG ELISA test, was observed. For the tested concentrations intra-assay, inter-assay, accuracy, sensitivity, specificity and coefficients of variations were determined as ≤15%. In-house biotin-avidin tetanus IgG ELISA test can be an alternative method to in vivo mouse neutralization method for the detection of levels ≤1.0IU/ml. By using in-house biotin-avidin tetanus IgG ELISA test, individuals with non protective levels, will be reliably detected. Copyright © 2017. Published by Elsevier B.V.
Bodjo, Sanne Charles; Baziki, Jean-de-Dieu; Nwankpa, Nick; Chitsungo, Ethel; Koffi, Yao Mathurin; Couacy-Hymann, Emmanuel; Diop, Mariame; Gizaw, Daniel; Tajelser, Idris Badri Adam; Lelenta, Mamadou; Diallo, Adama; Tounkara, Karim
2018-07-01
Peste des petits ruminants (PPR) is a contagious and economically important disease affecting production of small ruminants (i.e., sheep and goats). Taking into consideration the lessons learnt from the Global Rinderpest Eradication Programme (GREP), PPR is now targeted by the international veterinary community as the next animal disease to be eradicated. To support the African continental programme for the control of PPR, the Pan African Veterinary Vaccine Centre of the African Union (AU-PANVAC) is developing diagnostics tools. Here, we describe the development of a blocking enzyme-linked immunosorbent assay (bELISA) that allows testing of a large number of samples for specific detection of antibodies directed against PPR virus in sheep and goat sera. The PPR bELISA uses an anti-haemagglutinin (H) monoclonal antibody (MAb) as a competitor antibody, and tests results are interpreted using the percentage of inhibition (PI) of MAb binding generated by the serum sample. PI values below or equal to 18% (PI ≤ 18%) are negative, PI values greater than or equal to 25% (PI ≥ 25%) are positive, and PI values greater than 18% and below 25% are doubtful. The diagnostic specificity (DSp) and diagnostic sensitivity (DSe) were found to be 100% and 93.74%, respectively. The H-based PPR-bELISA showed good correlation with the virus neutralization test (VNT), the gold standard test, with a kappa value of 0.947. The H-based PPR-bELISA is more specific than the commercial kit ID Screen® PPR Competition (N-based PPR-cELISA) from IDvet (France), but the commercial kit is slightly more sensitive than the H-based PPR-bELISA. The validation process also indicated good repeatability and reproducibility of the H-based PPR-bELISA, making this new test a suitable tool for the surveillance and sero-monitoring of the vaccination campaign.
Murata, Takashi; Tsuzaki, Kokoro; Nirengi, Shinsuke; Watanabe, Tomokazu; Mizutani, Yukako; Okada, Hayami; Tsukamoto, Masami; Odori, Shinji; Nakagawachi, Reiko; Kawaguchi, Yaeko; Yoshioka, Fumi; Yamada, Kazunori; Shimatsu, Akira; Kotani, Kazuhiko; Satoh-Asahara, Noriko; Sakane, Naoki
2017-07-01
The distributer of the anti-glutamic acid decarboxylase antibody assay kit using radioimmunoassay (RIA) recently announced its discontinuation, and proposed an alternative kit using enzyme-linked immunosorbent assay (ELISA). The aim of the present study was to investigate the diagnostic values of the anti-glutamic acid decarboxylase antibody by RIA and ELISA among type 1 diabetes mellitus patients and control participants. A total of 79 type 1 diabetes mellitus patients and 79 age-matched controls were enrolled and assessed using RIA and ELISA. Sensitivity, specificity, positive predictive values and negative predictive values were calculated for cut-off values (RIA = 1.5 U/mL and ELISA = 5.0 U/mL, respectively). Kappa coefficients were used to test for agreements between the RIA and ELISA methods regarding the diagnosis of type 1 diabetes mellitus. The sensitivity, specificity, positive predictive values, and negative predictive values for diagnosing type 1 diabetes mellitus were 57.0, 97.5, 95.7, and 69.4% by RIA, and 60.8, 100.0, 100.0 and 71.8% by ELISA, respectively. The diagnosis of type 1 diabetes mellitus using the RIA and ELISA methods showed substantial agreement with the kappa values of 0.74 for all participants, and of 0.64 for the acute type; however, there was moderate agreement with the kappa value of 0.56 for the slowly progressive type. The present study suggests that both anti-glutamic acid decarboxylase antibody by RIA and ELISA was useful for diagnosing type 1 diabetes mellitus. However, in the slowly progressive type, the degree of agreement of these two kits was poorer compared with those in all participants or in the acute type. © 2016 The Authors. Journal of Diabetes Investigation published by Asian Association for the Study of Diabetes (AASD) and John Wiley & Sons Australia, Ltd.
Belo, Vinícius Silva; Gregório, Eliana Aparecida; Teixeira-Neto, Rafael Gonçalves; da Rocha Lima, Ana Cristina Vianna Mariano; Pereira, Agnes Antônia Sampaio; Marcelino, Andreza Pain; Paz, Gustavo Fontes; da Silva, Eduardo Sérgio
2017-10-01
One of the key components of the Brazilian Program for the Control of Visceral Leishmaniasis (PCLV) is the euthanasia of Leishmania-infected canine reservoirs, the detection of which depends on a screening procedure involving a Dual Path Platform ® (DPP) immunoassay and a confirmatory enzyme-linked immunosorbent assay (ELISA). The aims of the present study were to evaluate the reliability of these techniques in a region of recent transmission of canine VL, to follow up the seroconversion 3-4 months after the initial diagnosis of DPP reactive but ELISA indeterminate or non-reactive dogs, and to identify the species of Leishmania in circulation in the area. Each animal was submitted to DPP under field conditions, performed by municipal health workers using peripheral blood (DPP-field), to DPP under laboratory conditions using serum (DPP-lab) and to ELISA using serum. The agreements between the tests were determined using McNemar's χ 2 test, Cohen's kappa coefficient (k) at the 95% confidence interval and prevalence-adjusted bias-adjusted kappa (PABAK). Of the 1130 dogs examined, 74.2% were non-reactive in all three tests applied. Based on the PCLV positive-infection criterion, seroprevalence was 8.9% (101/1130) with 83.2% (84/101) of infected animals showing reactivity in all three tests while 7.8% (8/101) were reactive in DPP-field and ELISA and 8.9% (9/101) in DPP-lab and ELISA. The proportions of disagreements were substantial in all comparisons. Inter-rater reliability between DPP-field and ELISA (k=0.55; PABAK=0.78) and DPP-lab and ELISA (k=0.59; PABAK=0.81) were considered moderate, while that between DPP-field and DPP-lab (k=0.61; PABAK=0.79) was classified as marginally good. The proportion of seroconversions in DPP reactive animals that were initially ELISA indeterminate was significantly higher than in those that were DPP reactive but initially ELISA non-reactive. Restriction fragment length polymorphism analysis revealed the presence of Leishmania infantum, the etiologic agent of VL, in bone marrow samples from VL-infected animals. Our data showed that the techniques and protocols currently employed in the PCLV screening approach are not entirely reliable. Further consideration should be given to monitoring dogs with undetermined results in ELISA and a better training should be provided for health workers responsible for performing DPP tests applied under field conditions. Copyright © 2017 Elsevier B.V. All rights reserved.
Robertson, D M; Stephenson, T; Pruysers, E; McCloud, P; Tsigos, A; Groome, N; Mamers, P; Burger, H G
2002-02-01
The aim of this study was to characterize the molecular wt forms of inhibins A and B and its free alpha-subunit present in serum from women with ovarian cancer as a basis for developing improved monoclonal antibody-based inhibin assays for monitoring ovarian cancer. Three new inhibin alpha-subunit (alphaC) ELISAs were developed using monoclonal antibodies directed to three nonoverlapping peptide regions of the alphaC region of the inhibin alpha-subunit. To characterize serum inhibin molecular wt forms present in women with ovarian cancer, existing inhibin immunoassays (inhibin A, inhibin B, and pro-alphaC) and the new alphaC ELISAs were applied to sera from women with granulosa cell tumors and mucinous carcinomas previously fractionated using a combined immunoaffinity chromatography, preparative SDS-PAGE, and electroelution procedure. The distribution and molecular size of dimeric inhibins and alpha-subunit detected were consistent with known mol wt forms of inhibins A and B and inhibin alpha-subunit and their precursor forms present in serum and follicular fluid from healthy women. The alphaC ELISAs recognized all known forms of inhibin and the free inhibin alpha-subunit, although differences between alphaC ELISAs were observed in their ability to detect high mol wt forms. To assess which of the alphaC ELISAs was preferred in application to ovarian cancer, the alphaC ELISAs were applied to serum from a range of normal postmenopausal women (n = 61) and postmenopausal women (n = 152) with ovarian (serous, mucinous, endometrioid, clear cell carcinomas, and granulosa cell tumors) and nonovarian (breast and colon) cancers. Despite differences in their ability to detect high mol wt forms of inhibin, the alphaC ELISAs showed similar sensitivity (i.e. proportion of cancer patients correctly detected) and specificity (proportion of controls correctly detected) indexes in the detection of mucinous carcinomas (84% and 95%) and granulosa cell tumors (100% and 95%) compared with earlier inhibin RIA or polyclonal antibody-based immunofluorometric assays. A combination of the alphaC ELISAs with the CA125 assay, an ovarian tumor marker that has a high sensitivity and specificity for other ovarian cancers (serous, clear cell, and endometrioid), resulted in an increase in sensitivity/specificity indexes (95% and 95%) for the all ovarian cancer group. These new monoclonal antibody-based inhibin alphaC ELISAs now provide practical and sensitive assays suitable for evaluation as diagnostic tests for monitoring ovarian cancers.
Validation of ELISAs for the detection of antibodies to Sarcoptes scabiei in pigs.
van der Heijden, H M; Rambags, P G; Elbers, A R; van Maanen, C; Hunneman, W A
2000-03-28
An Enzyme-linked ImmunoSorbent Assay (ELISA) was developed for the detection of antibodies to Sarcoptes scabiei. This 'Animal Health Service'-ELISA (AHS-ELISA) was compared with a commercial test (Checkit(R) Sarcoptest) using experimental and field sera. The experimental study was a contact infestation experiment. Eighty piglets were randomly divided between the experimental and control group. After introduction of three Sarcoptes scabiei var. suis infested pigs in the experimental group, both groups were monitored by determining scratching indices, taking ear scrapings and blood samples in Weeks 0, 2, 4, 6, 8, 12 and 16. Four pigs in the control group were immunised with either Dermatophagoides pteronyssinus (Dp) antigens (n=2), or Acarus siro (As) antigens (n=2). In the control group all (non-immunised) pigs were negative in all tests. In the experimental group only slightly elevated scratching indices were observed, with a maximum in Week 8. After 2 weeks for the first time an ear scraping was positive (2.5%). In Week 8 the highest number of positive ear scrapings were found (25.0%). Positive results in the Sarcoptest were first obtained in Week 12 (10.5% positive), while eventually 29.0% of the finishing pigs were positive after 16 weeks. The AHS-ELISA first detected a serological response after 6 weeks (5. 0% positives), increasing until after 16 weeks a large proportion (74.2%) of the finishing pigs were seropositive, making the AHS-ELISA the most sensitive test. In the AHS-ELISA one As-immunised pig remained seronegative, but the other hyper-immunised pigs crossreacted. In the Sarcoptest, only Dp-immunised pigs had elevated Optical Densities (OD's) albeit below the cut-off level. Although hyper-immunisation is not a representation of field conditions, it cannot be excluded that the AHS-ELISA is not 100% specific.Field samples were taken from 20 sows in 30 herds, classified as mange-free, suspect, or infested. On a herd level there was high agreement among the ELISAs. Both serological tests were suitable to distinguish mange-free herds from infested herds. In one infested herd the decline of maternal antibody in piglets was studied by sampling 40 piglets from 20 different litters. The lowest average OD using the AHS-ELISA was found at 5 weeks of age, followed by a significant increase at 7 weeks. The average OD with the Sarcoptest was at a minimum level at 3 weeks, but no increase was found later. For screening of herds, interference of maternal antibodies is avoided by sampling at an age of 7 weeks or older.
78 FR 6120 - Government-Owned Inventions; Availability for Licensing
Federal Register 2010, 2011, 2012, 2013, 2014
2013-01-29
..., including immunoprecipitation, western blot analysis, immunohistochemistry, ELISA, etc. Competitive... immunoprecipitation, western blot analysis, immunohistochemistry, ELISA, etc. Competitive Advantages: Binding of a new...
A Protein Microarray ELISA for the Detection of Botulinum neurotoxin A
DOE Office of Scientific and Technical Information (OSTI.GOV)
Varnum, Susan M.
An enzyme-linked immunosorbent assay (ELISA) microarray was developed for the specific and sensitive detection of botulinum neurotoxin A (BoNT/A), using high-affinity recombinant monoclonal antibodies against the receptor binding domain of the heavy chain of BoNT/A. The ELISA microarray assay, because of its sensitivity, offers a screening test with detection limits comparable to the mouse bioassay, with results available in hours instead of days.
Identification of Causes and Treatments for Chronic Pain in a Model of Gulf War Illness
2017-10-01
saline delivered. Euthanasia and necropsy at days 5 and 20 post acidic/normal saline, and tissue analysis performed ( ELISA , Western Blot, LC-MS...performed ( ELISA , Western Blot, LC-MS). Milestone 3: the association between GWI-induced musculoskeletal pain and neuroinflammation, as well as the...thresholds. Serum samples analysed by ELISA . Major Task 7: Acidic/normal saline administered 180 days after final DFP injection; pharmacological reversal
DOE Office of Scientific and Technical Information (OSTI.GOV)
Caprini, Chiara, E-mail: chiara.caprini@cea.fr; Hindmarsh, Mark; Huber, Stephan
We investigate the potential for the eLISA space-based interferometer to detect the stochastic gravitational wave background produced by strong first-order cosmological phase transitions. We discuss the resulting contributions from bubble collisions, magnetohydrodynamic turbulence, and sound waves to the stochastic background, and estimate the total corresponding signal predicted in gravitational waves. The projected sensitivity of eLISA to cosmological phase transitions is computed in a model-independent way for various detector designs and configurations. By applying these results to several specific models, we demonstrate that eLISA is able to probe many well-motivated scenarios beyond the Standard Model of particle physics predicting strong first-ordermore » cosmological phase transitions in the early Universe.« less
Rubin, I; Lykkegaard, S; Olsen, A A; Selmer, J; Ballegaard, M
1988-01-01
Monoclonal antibodies were produced against human angiotensinogen. An enzyme linked immunosorbent assay (ELISA) was developed using a high affinity monoclonal antibody as catching antibody and a polyclonal rabbit anti human angiotensinogen antibody as detecting antibody in a "sandwich" ELISA. Linear range of the ELISA was 15-450 pmol/l of human angiotensinogen. Intra- and inter- assay variation coefficients were in the range of 2% to 8%. A correlation coefficient, r = 0.97, (n = 20), with values obtained by radioimmunoassay. This correlation coefficient, obtained by using both normal and pregnant sera, confirmed that the ELISA fulfill the requirements for clinical useful assay. Characterization of the antibodies were performed with respect to affinity constant and epitopes.
Mobile phone based ELISA (MELISA).
Zhdanov, Arsenii; Keefe, Jordan; Franco-Waite, Luis; Konnaiyan, Karthik Raj; Pyayt, Anna
2018-04-30
Enzyme-linked immunosorbent assay (ELISA) is one of the most important technologies for biochemical analysis critical for diagnosis and monitoring of many diseases. Traditional systems for ELISA incubation and reading are expensive and bulky, thus cannot be used at point-of-care or in the field. Here, we propose and demonstrate a new miniature mobile phone based system for ELISA (MELISA). This system can be used to complete all steps of the assay, including incubation and reading. It weighs just 1 pound, can be fabricated at low cost, portable, and can transfer test results via mobile phone. We successfully demonstrated how MELISA can be calibrated for accurate measurements of progesterone and demonstrated successful measurements with the calibrated system. Copyright © 2017 Elsevier B.V. All rights reserved.
Code of Federal Regulations, 2011 CFR
2011-01-01
... Test; Fluorescent Antibody Tissue Section Test; Enzyme-Linked Immunosorbent Assay (ELISA) Test, except for approved differential pseudorabies tests other than the glycoprotein I (gpI) ELISA test; Latex...
Code of Federal Regulations, 2014 CFR
2014-01-01
... Test; Fluorescent Antibody Tissue Section Test; Enzyme-Linked Immunosorbent Assay (ELISA) Test, except for approved differential pseudorabies tests other than the glycoprotein I (gpI) ELISA test; Latex...
Code of Federal Regulations, 2013 CFR
2013-01-01
... Test; Fluorescent Antibody Tissue Section Test; Enzyme-Linked Immunosorbent Assay (ELISA) Test, except for approved differential pseudorabies tests other than the glycoprotein I (gpI) ELISA test; Latex...
Code of Federal Regulations, 2010 CFR
2010-01-01
... Test; Fluorescent Antibody Tissue Section Test; Enzyme-Linked Immunosorbent Assay (ELISA) Test, except for approved differential pseudorabies tests other than the glycoprotein I (gpI) ELISA test; Latex...
Code of Federal Regulations, 2012 CFR
2012-01-01
... Test; Fluorescent Antibody Tissue Section Test; Enzyme-Linked Immunosorbent Assay (ELISA) Test, except for approved differential pseudorabies tests other than the glycoprotein I (gpI) ELISA test; Latex...
Karen, Aly; Sousa, Noelita Melo De; Beckers, Jean-François; Bajcsy, Árpád Csaba; Tibold, János; Mádl, István; Szenci, Ottó
2015-08-01
The present study aimed to compare the accuracy of a commercial PAG-ELISA test (Bovine Preg Test 29) and bovine pregnancy-associated glycoprotein radioimmunoassay (PAG-RIA) for diagnosing pregnancy at Day 28 after insemination in dairy cows. Transrectal ultrasonography (TRUS) was performed in 100 Holstein-Friesian cows at Day 28 after artificial insemination (AI; Day 0) to diagnose pregnancy. After TRUS examination, blood sample was collected from the coccygeal vessels of each cow to measure the concentrations of bPAGs by PAG-RIA test and Bovine Preg Test 29. Milk samples were collected at Days 0, 21 and 28 for measurement of progesterone (P4) by ELISA test. The cows were re-examined by TRUS at Day 42 to confirm the pregnancy diagnoses. The actual gold standard was based on TRUS outcomes at Day 28 that agreed with the outcomes of PAG-RIA test or PAG-ELISA test. If the outcomes of TRUS at Day 28 and PAG-RIA test and PAG-ELISA test did not agree, the gold standard was based on the outcome of TRUS at Day 42. Out of 100 inseminated cows, 41 were confirmed pregnant at Day 28 after AI. Based on the actual gold standard, the sensitivity of TRUS, PAG-ELISA and PAG-RIA tests for diagnosing pregnant cows at Day 28 were 92.7%, 90.2% and 100%, while the specificity of the three tests for diagnosing non-pregnant cows were 91.5%, 98.3% and 94.4%, respectively. The overall accuracy of the three tests were 92%, 95% and 97%, respectively. The degree of agreement (Kappa±S.E.) between PAG-RIA and PAG-ELISA test was 0.90 ±0.04. The degrees of agreement between PAG-RIA and PAG-ELISA and TRUS at Day 28 were 0.80±0.05 and 0.76±0.06, respectively. In conclusion, the commercial PAG-ELISA test is a highly accurate method for diagnosing early pregnancy in dairy cows on Day 28 after AI and may be used as an alternative method to the TRUS and the PAG-RIA test. Copyright © 2015 Elsevier B.V. All rights reserved.
Ledesma, Darién; Berriatua, Eduardo; Thomas, M Carmen; Bernal, Luis Jesús; Ortuño, María; Benitez, Celia; Egui, Adriana; Papasouliotis, Kostas; Tennant, Bryn; Chambers, Julia; Infante, Juan José; López, Manuel Carlos
2017-10-23
Leishmania infantum is a protozoan parasite transmitted by phlebotomine sand flies that causes life-threatening disease in humans and dogs. The dog is the primary reservoir of the parasite and early diagnosis of canine leishmaniosis is crucial at the clinical and epidemiological level. The currently available serological tests for CanL diagnostic show limitations therefore the aim of the present study was to investigate the diagnostic performance of an indirect antibody ELISA based on the Leishmania infantum recombinant antigen PFR1 in asymptomatically infected dogs. One hundred fifty-six dogs including Leishmania-free experimental Beagles and pet dogs from England, Scotland and Leishmania-endemic Murcia in Spain, were tested with the assay. The later were also tested with two commercial L. infantum crude antigen ELISAs (INgezim and Civtest, respectively) and a real-time kinetoplast PCR test. Anti-PFR1 antibodies were detected in the four groups of dogs, and the mean log-transformed optical density (OD) values were lowest in Beagles and in dogs from England and highest among dogs from Murcia (p < 0.05). Using the highest OD in beagles as the PFR1 ELISA cut-off point, the estimated seroprevalence was 27% (14-40%) in dogs from Murcia, 4% (0-9%) in dogs from Scotland and 3% (0-8%) in dogs from England (p < 0.05). Seroprevalence in dogs from Murcia according to the INgezim and Civtest ELISAs were 24% (12-37%) and 31% (18-45%), respectively, whilst the prevalence of infection based on PCR in these dogs was 73% (60-86). The percentages of PFR1-positive dogs that tested negative on the INgezim and Civtest ELISAs were 30% and 35%, respectively, and all of them tested positive on the PCR test. Relative to the PCR, the specificity, sensitivity and area under the ROC curve of the PFR1 ELISA were 100%, 36% and 0.74 (0.63-0.86), respectively. The ability shown by the PFR1 ELISA to detect infected dogs that go undetected by the crude antigen ELISAs is clinically and epidemiologically useful and PFR1 could be considered a candidate for a multi-antigen-based immunoassay for early detection of L. infantum infected dogs.
Code of Federal Regulations, 2013 CFR
2013-01-01
... Immunosorbent Assay (ELISA) Test, except for approved differential pseudorabies tests other than the glycoprotein I (gpI) ELISA test; 5. Latex Agglutination Test (LAT); and 6. Particle Concentration Fluorescence...
Code of Federal Regulations, 2012 CFR
2012-01-01
... Immunosorbent Assay (ELISA) Test, except for approved differential pseudorabies tests other than the glycoprotein I (gpI) ELISA test; 5. Latex Agglutination Test (LAT); and 6. Particle Concentration Fluorescence...
Code of Federal Regulations, 2014 CFR
2014-01-01
... Immunosorbent Assay (ELISA) Test, except for approved differential pseudorabies tests other than the glycoprotein I (gpI) ELISA test; 5. Latex Agglutination Test (LAT); and 6. Particle Concentration Fluorescence...
Code of Federal Regulations, 2011 CFR
2011-01-01
... Immunosorbent Assay (ELISA) Test, except for approved differential pseudorabies tests other than the glycoprotein I (gpI) ELISA test; 5. Latex Agglutination Test (LAT); and 6. Particle Concentration Fluorescence...
Code of Federal Regulations, 2010 CFR
2010-01-01
... Immunosorbent Assay (ELISA) Test, except for approved differential pseudorabies tests other than the glycoprotein I (gpI) ELISA test; 5. Latex Agglutination Test (LAT); and 6. Particle Concentration Fluorescence...
Panda, Rakhi; Boyer, Marc; Garber, Eric A E
2017-12-01
A novel competitive ELISA was developed utilizing the G12, R5, 2D4, MIoBS, and Skerritt antibody-HRP conjugates employed in nine commercial ELISA test kits that are routinely used for gluten detection. This novel multiplex competitive ELISA simultaneously measures gliadin-, deamidated gliadin-, and glutenin-specific epitopes. The assay was used to evaluate 20 wheat beers, 20 barley beers, 6 barley beers processed to reduce gluten, 15 soy sauces, 6 teriyaki sauces, 6 Worcestershire sauces, 6 vinegars, and 8 sourdough breads. For wheat beers, the apparent gluten concentration values obtained by the G12 and Skerritt antibodies were typically higher than those obtained using the R5 antibodies. The sourdough bread samples resulted in higher apparent gluten concentration values with the Skerritt antibody, while the values generated by the G12 and R5 antibodies were comparable. Although the soy-based sauces showed non-specific inhibition with the multiple R5 and G12 antibodies, their overall profile was distinguishable from the other categories of fermented foods. Cluster analysis of the apparent gluten concentration values obtained by the multiplex competitive ELISA, as well as the relative response of the nine gluten-specific antibodies used in the assay to different gluten proteins/peptides, distinguishes among the different categories of fermented-hydrolyzed foods by recognizing the differences in the protein/peptide profiles characteristic of each product. This novel gluten-based multiplex competitive ELISA provides insight into the extent of proteolysis resulting from various fermentation processes, which is essential for accurate gluten quantification in fermented-hydrolyzed foods. Graphical abstract A novel multiplex competitive ELISA for the detection and characterization of gluten in fermented-hydrolyzed foods.
Koestel, Carole; Simonin, Céline; Belcher, Sandrine; Rösti, Johannes
2016-08-01
Since the early 2000s, labeling of potentially allergenic food components to protect people who suffer from food allergies is compulsory in numerous industrialized countries. In Europe, milk and egg components used during the winemaking process must be indicated on the label since July 1, 2012. Several ELISA procedures have been developed to detect allergenic residues in wines. However, the complexity of the wine matrix can inhibit the immunoenzymatic reaction. The aim of this study was to implement an ELISA assay for the detection of ovalbumin in red wines using commercially available antibodies. The specificity of the acquired antibodies and the absence of cross reactivity were assessed by immunoblotting and ELISA. An ELISA assay with a LOD of 14.2 μg/L and a LOQ of 56.4 μg/L of ovalbumin in aqueous solution was obtained. Differences in ELISA signals were observed when analyzing various fining agents, although reproducible conformation of the antigen could be reached for the comparison of ovalbumin and Ovicolle. The differences between samples in terms of pH could be leveled but the inhibition of the ELISA signal, positively correlated to the tannin content of the wines, could not be suppressed. Thus, standard curves of ovalbumin in several wines were obtained by relative quantification. The control steps and the difficulties encountered presented in this study should be considered by anybody working toward the development of ELISA assays for the detection of allergenic residues in complex food matrices. © 2016 The Authors. Journal of Food Science published by Wiley Periodicals, Inc. on behalf of Institute of Food Technologists.
Jefferies, Ryan; Morgan, Eric R; Helm, Jenny; Robinson, Matthew; Shaw, Susan E
2011-12-01
This study reports the development of a real-time PCR assay and an indirect ELISA to improve on current detection of canine Angiostrongylus vasorum infection. A highly specific fluorescent probe-based, real-time PCR assay was developed to target the A. vasorum second internal transcribed spacer region and detected DNA in EDTA blood, lung tissue, broncho-alveolar larvage fluid, endotracheal mucus, pharyngeal swabs and faecal samples. PCR was fast (∼1 h), highly efficient when using EDTA blood samples, consistently detected a single molecule of parasite DNA and did not amplify DNA from other parasitic nematodes or definitive host species. An indirect ELISA was also developed using the soluble protein fraction from adult A. vasorum worms. Some cross-reactive antigen recognition was observed when tested against sera from dogs infected with Crenosoma vulpis (n = 8), Toxocara canis (n = 5) and Dirofilaria immitis (n = 5). This was largely overcome by setting the cut-off for a positive result at an appropriately high level. Field evaluation of the real-time PCR and ELISA was conducted by testing sera and EDTA blood from dogs with suspected A. vasorum infection (n = 148) and compared with the Baermann's larval migration test in faeces. Thirty-one dogs were positive by at least one test. Of these, 20 (65%) were detected by the Baermann method, 18 (58%) by blood PCR, 24 (77%) by ELISA and 28 (90%) by blood PCR and ELISA together. Combined testing using real-time PCR and ELISA therefore improved the detection rate of A. vasorum infection and holds promise for improved clinical diagnosis and epidemiological investigation.
Klaus, Christine; Beer, Martin; Saier, Regine; Schubert, Harald; Bischoff, Sabine; Süss, Jochen
2011-01-01
Tick-borne encephalitis (TBE) in animals is not well understood yet. TBE virus (TBEV) serology in several host species could be valuable for epidemiological analyses in the field as well as for the detection of clinical cases. However, performance and suitability of the available test systems are not well assessed. Therefore, we evaluated two commercial TBEV-ELISA kits in a pilot study and compared them for their suitability in veterinary applications. For this purpose, we tested 163 field collected goat sera and evaluated the results by serum neutralization test (SNT) as "gold standard". Twenty-eight SNT positive sera (17.2%) were detected. The best suited ELISA kit was used for determination of a species-specific cutoff for horses, cattle, sheep, goats, pigs, mice, dogs, rabbits and monkeys with defined sera from animals without known or with improbable contact to TBEV. The level of non-specific ELISA results does not only differ between animal species but may also be influenced by the age of the tested animals. The number of sera which tested false positive by ELISA was higher in older than in young sheep. In order to obtain defined polyclonal sera as references, two dogs, cattle, goats, sheep, rabbits and pigs each, as well as one horse and 90 mice were immunized four times with a commercially available TBEV vaccine. In conclusion, our results demonstrated that commercial TBEV-ELISA kits are suitable for application in veterinary medicine for both, verification of clinical TBE cases and epidemiological screening. However, positive ELISA results should be verified by SNT. Only a very low number of false negative ELISA-results were found.
Skibinska, A; Lee, A; Wylie, M; Smyth, V J; Welsh, M D; Todd, D
2015-01-01
The development of an indirect enzyme-linked immunosorbent assay (ELISA) for the serological diagnosis of Group B chicken astrovirus (CAstV) infections is described. The test was based on the use of an affinity-purified capsid antigen, specific to CAstV isolate 11672, produced as a glutathione-S-transferase N-terminal fusion protein by a recombinant baculovirus. Strongly positive ELISA signals were elicited against experimentally produced antisera raised to CAstVs from Group B (subgroups i and ii) but were negative for antisera raised to a Group A CAstV. Using a panel of 240 selected serum samples, 99% agreement was observed when the results obtained by ELISA were compared to those from an indirect immunofluorescence test for CAstV 11672. The ELISA test was applied to 68 serum sets comprising 1864 samples, which were obtained from parent and grandparent flocks originating mainly in the UK. Of the 52 sets containing ELISA-positive samples, 24 sets had >75% samples positive and nine sets had <25% samples positive and were regarded as having high and low seropositivities, respectively. Of the 1864 serum samples tested 1090 (58.5%) were ELISA positive and of these, 234 sera (21.5%) produced strongly positive signals, whereas moderately positive and weakly positive signals were produced by 562 (51.5%) and 294 (27%) sera. When used for flock screening purposes, this ELISA test can be used to (i) investigate the occurrence of first-time CAstV infections of parent flocks during lay and the possible adverse effects caused by vertically transmitted CAstV infections on broiler hatchability and performance and (ii) diagnose Group B CAstV infections within specific pathogen free flocks.
Monoclonal antibody-based serological methods for detecting Citrus tristeza virus in citrus groves.
Liu, Zhen; Chen, Zhe; Hong, Jian; Wang, Xuefeng; Zhou, Changyong; Zhou, Xueping; Wu, Jianxiang
2016-08-01
Citrus tristeza virus (CTV) is one of the most economically important citrus viruses and harms the citrus industry worldwide. To develop reliable and effective serological detection assays of CTV, the major capsid protein (CP) gene of CTV was expressed in Escherichia coli BL21 (DE3) using the expression vector pET-28a and purified through Ni+-NTA affinity chromatography. The recombinant protein was used to immunize BALB/c mice. Four hybridoma cell lines (14B10, 14H11, 20D5, and 20G12) secreting monoclonal antibodies (MAbs) against CTV were obtained through conventional hybridoma technology. The titers of MAb-containing ascitic fluids secreted by the four hybridoma lines ranged from 10(-6) to 10(-7) in indirect enzyme-linked immunosorbent assay (ELISA). Western blots showed that all four MAbs could specifically react with CTV CP. Using the prepared MAbs, dot-ELISA, Tissue print-ELISA, and triple antibody sandwich (TAS)-ELISA were developed to detect CTV in tree nurseries and epidemiological studies. The developed dot-ELISA and TAS-ELISA methods could detect CTV in crude extracts of infected citrus leaves with dilutions of 1:2560 and 1:10, 240 (w/v, g/mL), respectively. Tissue print-ELISA was particularly useful for large-scale field sample detection, mainly owing to its simplicity and lack of sample preparation requirements. The field survey revealed that CTV is prevalent on citrus trees in the Chongqing Municipality, Jiangxi Province, and Zhejiang Province of China. The coincidence rate of serological and RT-PCR test results reached more than 99.5%. The prepared MAbs against CTV and established sensitive and specific serological assays have a significant role in the detection and prevention and control of CTV in our country.
Usefulness of ELISA Methods for Assessing LPS Interactions with Proteins and Peptides
Martínez-Sernández, Victoria; Orbegozo-Medina, Ricardo A.; Romarís, Fernanda; Paniagua, Esperanza; Ubeira, Florencio M.
2016-01-01
Lipopolysaccharide (LPS), the major constituent of the outer membrane of Gram-negative bacteria, can trigger severe inflammatory responses during bacterial infections, possibly leading to septic shock. One approach to combatting endotoxic shock is to neutralize the most conserved part and major mediator of LPS activity (lipid A) with LPS-binding proteins or peptides. Although several available assays evaluate the biological activity of these molecules on LPS (e.g. inhibition of LPS-induced TNF-α production in macrophages), the development of simple and cost-effective methods that would enable preliminary screening of large numbers of potential candidate molecules is of great interest. Moreover, it would be also desirable that such methods could provide information about the possible biological relevance of the interactions between proteins and LPS, which may enhance or neutralize LPS-induced inflammatory responses. In this study, we designed and evaluated different types of ELISA that could be used to study possible interactions between LPS and any protein or peptide. We also analysed the usefulness and limitations of the different ELISAs. Specifically, we tested the capacity of several proteins and peptides to bind FITC-labeled LPSs from Escherichia coli serotypes O111:B4 and O55:B5 in an indirect ELISA and in two competitive ELISAs including casein hydrolysate (hCAS) and biotinylated polymyxin B (captured by deglycosylated avidin; PMX) as LPS-binding agents in the solid phase. We also examined the influence of pH, detergents and different blocking agents on LPS binding. Our results showed that the competitive hCAS-ELISA performed under mildly acidic conditions can be used as a general method for studying LPS interactions, while the more restrictive PMX-ELISA may help to identify proteins/peptides that are likely to have neutralizing properties in vitro or in vivo. PMID:27249227
Bromage, Sabri; Tselmen, Daria; Bradwin, Gary; Holick, Michael F; Ganmaa, Davaasaambuu
2017-01-01
Assay cost, quality, and availability pose challenges for vitamin D surveys in limited resource settings. This study aimed to validate an inexpensive vitamin D assay (ELISA) under real-world conditions in Mongolia, the northernmost developing country, to characterize the assay's usefulness and inform the design of epidemiologic studies in similar regions. We collected paired summer and winter serum samples from 120 men and women (aged 20-57 years) in urban and rural Mongolia, analyzed each sample for 25(OH)D concentration using both Immunodiagnostic Systems ELISA and DiaSorin LIAISON 25(OH)D TOTAL, and compared the assays using multiple statistics. LIAISON was itself validated by participation in the DEQAS program. Correlation and agreement between assays were higher in summer (Pearson's correlation=0.60, Spearman's rank correlation=0.67, Lin's concordance correlation=0.56) than winter (rP=0.37, rS=0.43, rC=0.33), although ELISA less accurately assigned subjects to sufficiency categories in summer (percent agreement=44%) than winter (58%), during the latter of which most subjects were deficient ([25(OH)D] categories used: >75 nmol/L (optimal), 50-75 nmol/L (adequate), 25-50 nmol/L (inadequate), <25 nmol/L (deficient)). Compared with LIAISON, ELISA tended to indicate higher vitamin D status in both seasons (mean paired difference: 7.0 nmol/L (95% CI: 3.5-10.5) in summer, 5.2 nmol/L (95% CI: 2.9-7.5) in winter). ELISA proved useful for measuring and ranking subjects' vitamin D status in Mongolia during summer, but levels were too low in winter to sensitively discriminate between subjects, and ELISA overestimated status in both seasons. These findings have implications for the timing and interpretation, respectively, of vitamin D surveys in highly deficient populations.
Liang, Cheng-Zhu; Cao, Rui-Bing; Wei, Jian-Chao; Zhu, Lai-Hua; Chen, Pu-Yan
2006-06-01
According to the antigenic analysis of equine arteritis virus (EAV) GL protein, one pair of primers were designed, with which the gene fragment coding the high antigenic domain of EAV GL protein was amplified from the EAV genome. The cloned gene was digested with BamH I and Xho I and then inserted into pET-32a and resulted pET-GL1. The pET-GL1 was transformed into the host cell BL21(DE3) and the expression was optimized including cultivation temperature and concentration of IPTG. The aim protein was highly expressed and the obtained recombinant protein manifested well reactiongenicity as was confirmed by Western blot. The recombinant GL1 protein was purified by the means of His * Bind resin protein purification procedure. Then an indirect ELISA was established to detect antibody against EAV with the purified GL1 protein as the coating antigen. The result showed that the optimal concentration of coated antigen was 9.65 microg/mL and the optimal dilution of serum was 1:80. The positive criterion of this ELISA assay is OD (the tested serum) > 0.4 and OD (the tested serum) /OD (the negative serum) > 2.0. The iGL-ELISA was evaluated versus micro-virus neutralization test. The ELISA was performed on 900 sera from which were preserved by this lab during horse entry/exit inspection, the agreement (94.1%) of these test were considered suitable for individual serological detection. In another test which 180 sera samples were detected by iGL-ELISA and INGEZIM ELISA kit respectively. The agreement ratio between the two methods is 95.6%.
Parween, Shahila; Nahar, Pradip
2013-10-15
In this communication, we report ELISA technique on an activated polypropylene microtest plate (APPµTP) as an illustrative example of a low cost diagnostic assay. Activated test zone in APPµTP binds a capture biomolecule through covalent linkage thereby, eliminating non-specific binding often prevalent in absorption based techniques. Efficacy of APPµTP is demonstrated by detecting human immunoglobulin G (IgG), human immunoglobulin E (IgE) and Aspergillus fumigatus antibody in patient's sera. Detection is done by taking the image of the assay solution by a desktop scanner and analyzing the color of the image. Human IgE quantification by color saturation in the image-based assay shows excellent correlation with absorbance-based assay (Pearson correlation coefficient, r=0.992). Significance of the relationship is seen from its p value which is 4.087e-11. Performance of APPµTP is also checked with respect to microtiter plate and paper-based ELISA. APPµTP can quantify an analyte as precisely as in microtiter plate with insignificant non-specific binding, a necessary prerequisite for ELISA assay. In contrast, paper-ELISA shows high non-specific binding in control sera (false positive). Finally, we have carried out ELISA steps on APPµTP by ultrasound waves on a sonicator bath and the results show that even in 8 min, it can convincingly differentiate a test sample from a control sample. In short, spectrophotometer-free image-based miniaturized ELISA on APPµTP is precise, reliable, rapid, and sensitive and could be a good substitute for conventional immunoassay procedures widely used in clinical and research laboratories. Copyright © 2013 Elsevier B.V. All rights reserved.
Yu, Fuxun; Le, Mai Quynh; Inoue, Shingo; Thai, Hong Thi Cam; Hasebe, Futoshi; Del Carmen Parquet, Maria; Morita, Kouichi
2005-07-01
Severe acute respiratory syndrome (SARS) is a recently emerged human disease associated with pneumonia. Inapparent infection with SARS coronavirus (CoV) is not well characterized. To develop a safe, simple, and reliable screening method for SARS diagnosis and epidemiological study, two recombinant SARS-CoV nucleocapsid proteins (N' protein and (N)Delta(121) protein) were expressed in Escherichia coli, purified by affinity chromatography, and used as antigens for indirect, immunoglobulin G enzyme-linked immunosorbent assays (ELISA). Serum samples collected from healthy volunteers and SARS patients in Vietnam were used to evaluate the newly developed methods. The N' protein-based ELISA showed a highly nonspecific reaction. The (N)Delta(121) protein-based ELISA, with a nonspecific reaction drastically reduced compared to that of the nearly-whole-length N' protein-based ELISA, resulted in higher rates of positive reactions, higher titers, and earlier detection than the SARS-CoV-infected cell lysate-based ELISA. These results indicate that our newly developed SARS-CoV (N)Delta(121) protein-based ELISA is not only safe but also a more specific and more sensitive method to diagnose SARS-CoV infection and hence a useful tool for large-scale epidemiological studies. To identify inapparent SARS-CoV infections, serum samples collected from health care workers (HCWs) in Vietnam were screened by the (N)Delta(121) protein-based ELISA, and positive samples were confirmed by a virus neutralization test. Four out of 149 HCWs were identified to have inapparent SARS-CoV infection in Vietnam, indicating that subclinical SARS-CoV infection in Vietnam is rare but does exist.
Yu, Fuxun; Le, Mai Quynh; Inoue, Shingo; Thai, Hong Thi Cam; Hasebe, Futoshi; del Carmen Parquet, Maria; Morita, Kouichi
2005-01-01
Severe acute respiratory syndrome (SARS) is a recently emerged human disease associated with pneumonia. Inapparent infection with SARS coronavirus (CoV) is not well characterized. To develop a safe, simple, and reliable screening method for SARS diagnosis and epidemiological study, two recombinant SARS-CoV nucleocapsid proteins (N′ protein and NΔ121 protein) were expressed in Escherichia coli, purified by affinity chromatography, and used as antigens for indirect, immunoglobulin G enzyme-linked immunosorbent assays (ELISA). Serum samples collected from healthy volunteers and SARS patients in Vietnam were used to evaluate the newly developed methods. The N′ protein-based ELISA showed a highly nonspecific reaction. The NΔ121 protein-based ELISA, with a nonspecific reaction drastically reduced compared to that of the nearly-whole-length N′ protein-based ELISA, resulted in higher rates of positive reactions, higher titers, and earlier detection than the SARS-CoV-infected cell lysate-based ELISA. These results indicate that our newly developed SARS-CoV NΔ121 protein-based ELISA is not only safe but also a more specific and more sensitive method to diagnose SARS-CoV infection and hence a useful tool for large-scale epidemiological studies. To identify inapparent SARS-CoV infections, serum samples collected from health care workers (HCWs) in Vietnam were screened by the NΔ121 protein-based ELISA, and positive samples were confirmed by a virus neutralization test. Four out of 149 HCWs were identified to have inapparent SARS-CoV infection in Vietnam, indicating that subclinical SARS-CoV infection in Vietnam is rare but does exist. PMID:16002634
Desquesnes, M; Bengaly, Z; Millogo, L; Meme, Y; Sakande, H
2001-03-01
In Africa, the main pathogenic trypanosomes of livestock are Trypanosoma vivax, T. congolense and T. brucei. The geographical distributions and hosts of these three species are very similar. As they differ markedly in pathogenicity and epidemiology, however, a species-specific serological test for infection would be very useful for epidemiological studies. The antibody-ELISA (Ab-ELISA) that have been developed for detecting the Trypanosoma spp. most commonly infecting livestock give satisfactory sensitivity and genus specificity. Unfortunately, they are not species-specific because of strong cross-reactions between the pathogenic Trypanosoma spp. In the present study, carried out in Burkina Faso, the results of standardized Ab-ELISA for T. vivax, T. brucei or T. congolense were compared using 1288 plasma samples from sheep experimentally infected with T. vivax, T. evansi and/or T. congolense. If the results were interpreted, as usual, only using a positivity threshold (PT), the strong cross-reactions observed led to a mean species-specificity of < 30%. However, analysis of the reactions observed in the three types of Ab-ELISA revealed that the homologous reactions were stronger than the heterologous for almost all of the single and mixed infections (98.3% and 99.0%, respectively). In monospecific infections exceeding the PT study of the positivity score produced in each of the three types of Ab-ELISA increased species-specificity to > 96%. It therefore appears that comparison of the strengths of the reactions seen in Ab-ELISA could greatly improve sero-epidemiological surveys of trypanosome infections in domestic ruminants, although the technique remains to be evaluated in experimentally infected cattle.
EVALUATION AND IMPORTANCE OF SELECTED MICROBIOLOGICAL METHODS IN THE DIAGNOSIS OF HUMAN BRUCELLOSIS
Šiširak, Maida; Hukić, Mirsada
2009-01-01
Brucellosis is an important public health problem in Bosnia and Herzegovina. The diagnosis of bru-cellosis in the country without any experiences with this kind of infection may be very difficult. The aim of this study was to evaluate diagnostic methods: Rose Bengal test, blood cultures and ELISA IgM and IgG in the patients with brucellosis. The study included 91 brucellosis patients in the period 2004 to 2007. All the patients were treated at the Clinic for Infectious Diseases, University of Sarajevo Clinics Centre. Blood cultures were positive in 28/91 (30, 8%) patients. This method often needs a long period of incubation and specimens need to be obtained early. These limitations make serology the most useful tool for the laboratory diagnosis of Brucella infection. Rose Bengal is a rapid plate agglutination test, very sensitive irrespective of the stage of the disease. In our study, Rose Bengal test was positive in all patients 91/91 (100, 0%). Brucella IgM antibodies with ELISA were positive in 59/91 (64, 8%). Brucella IgG antibodies with ELISA were positive in 51/91 (56%). In order to determine the diagnostic value of the different tests, we compared the sensitivity among test-methods: Rose Bengal test-100.0%, blood culture-30.8%, ELISA IgM-64.8% and ELISA IgG-56.1%. Sensitivity of test methods was different in the different stages of illness. It is necessary to use combination of different tests such are blood culture, Rose Bengal test and ELISA in order to ensure the diagnosis. Rose Bengal test is excellent for the screening. Blood culture is a method of choice for the diagnosis acute infection. ELISA is a very good method for the diagnostic chronic disease and relapse. PMID:19754473
Silva, Renata K N R; Pacheco, Flávia T F; Martins, Adson S; Menezes, Joelma F; Costa-Ribeiro, Hugo; Ribeiro, Tereza C M; Mattos, Ângela P; Oliveira, Ricardo R; Soares, Neci M; Teixeira, Márcia C A
2016-12-01
Techniques for Giardia diagnosis based on microscopy are usually applied as routine laboratory testing; however, they typically exhibit low sensitivity. This study aimed to evaluate Giardia duodenalis and other intestinal parasitic infections in different pediatric groups, with an emphasis on the comparison of Giardia diagnostic techniques. Feces from 824 children from different groups (diarrheic, malnourished, with cancer and from day care) were examined by microscopy and ELISA for Giardia, Cryptosporidium sp. and Entamoeba histolytica coproantigen detection. Giardia-positive samples from day-care children, identified by either microscopy or ELISA, were further tested by PCR targeting of the β-giardin and Gdh genes. Statistically significant differences (P<0.05) were observed when comparing the frequency of each protozoan among the groups. Giardia duodenalis was more frequent in day-care children and Cryptosporidium sp. in diarrheic and malnourished groups; infections by Entamoeba histolytica were found only in children with diarrhea. Considering positivity for Giardia by at least one method, ELISA was found to be more sensitive than microscopy (97% versus 55%). To examine discrepancies among the diagnostic methods, 71 Giardia-positive stool samples from day-care children were tested by PCR; of these, DNA was amplified from 51 samples (77.4%). Concordance of positivity between microscopy and ELISA was found for 48 samples, with 43 confirmed by PCR. Parasite DNA was amplified from eleven of the 20 Giardia samples (55%) identified only by ELISA. This study shows the higher sensitivity of ELISA over microscopy for Giardia diagnosis when a single sample is analyzed and emphasizes the need for methods based on coproantigen detection to identify this parasite in diarrheic fecal samples. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Gibertoni, Aliandra M.; Montassier, Maria de Fátima S.; Sena, Janete A. D.; Givisiez, Patrícia E. N.; Furuyama, Cibele R. A. G.; Montassier, Hélio J.
2005-01-01
A Saccharomyces cerevisiae-expressed nucleocapsid (N) polypeptide of the M41 strain of infectious bronchitis virus (IBV) was used as antigen in a recombinant yeast-expressed N protein-based enzyme-linked immunosorbent assay (Y-N-ELISA). The Y-N-ELISA was rapid, sensitive, and specific for detecting chicken serum antibodies to IBV, and it compared favorably with a commercial ELISA. PMID:15815038
Adult Stem Cell-Based Enhancement of Nerve Conduit for Peripheral Nerve Repair
2017-10-01
neurotrophically activated cell types and conditioned media (via RT-PCR and ELISA of neurotrophic factors), followed by cell storage Specific objective 9...Mesenchymal Progenitor Cells (NI-MiMPCs) and Mesenchymal Stem Cells (MSCs), quantified via ELISA . MiMPCs and MSCs were cultured in neurotrophic induction...LIF, (E) osteonectin, and (F) clusterin. All ELISA results are expressed in pg/ml or ng/ml produced per million cells. Medium taken from NI-MiMPC
The Thoc1 Ribonucleoprotein as a Novel Biomarker for Prostate Cancer Treatment Assignment
2017-10-01
PI Mohler). Immunostaining of prostate cancer biopsy specimen of patients who qualified for active surveillance is complete (PI Goodrich). ELISA assay...specimens for use in constructing tissue microarrays, developing and optimizing ELISA assays to detect Thoc1 protein and anti-Thoc1 autoantibodies...set of TMAs made from 700 patients available at RPCI has been immunostained for PMP22 (figure 5). ELISA assays for measuring pThoc1 and pThoc1
2016-04-01
streptavidin-phycoerythrin (PE) similar to sandwich enzyme-linked immunosorbent assays ( ELISAs ). The 3 fluorescent markers (2 beads plus PE) allow for...within the kit, this worked out to a set of expensive, problematic, and subjective ELISA . The space on the black-96 well plate was split between cell...ARL US Army Research Laboratory BBB blood–brain barrier CSF cerebral spinal fluid DOD US Department of Defense ELISA enzyme-linked immunosorbent
Follistatin: A Potential Anabolic Treatment for Re-Innervated Muscle
2017-09-01
Observations: ELISA , muscle histology, nerve histology, etc.are pending and no final conclusions can be made. 1. 3-month Protein: a. Muscle Weight: No...and virus needed for the study and also helped in Pilot Study- ELISA . He presented the following abstract in VCU School of Medicine Student Research...denervation groups (1-6): ▪ Follistatin ELISA – Run the assay, collect data, and prepare to present data ▪ Muscle Histology – Process tissue, image the
Impact of Embedded Military Metal Alloys on Skeletal Physiology in an Animal Model
2017-04-04
turnover were completed and statistical comparison performed for each time point. Each ELISA was performed according to the instructions within each kit...expectations for controls. Results of osteocalcin ELISA were evaluated and any results with a coefficient of variation greater than 25% were omitted...Results of TRAP5b ELISA were evaluated and any results with a coefficient of variation greater than 25% were omitted from analysis. Measures of TRAP5b
The Thoc1 Ribonucleoprotein as a Novel Biomarker for Prostate Cancer Treatment Assignment
2016-10-01
patients on active surveillance is ongoing (PI Mohler). Developing ELISA assays for measuring pThoc1 and pThoc1 autoantibodies is complete (PI...assessment of 1146 patient specimens for use in constructing tissue microarrays, developing and optimizing ELISA assays to detect anti-Thoc1 autoantibodies...700 patients available at RPCI has been immunostained for PMP22 (figure 3). ELISA assays for measuring pThoc1 and pThoc1 autoantibodies have been
N-Terminal Tau Fragments as Biomarkers for Alzheimer’s Disease and Neurotrauma
2017-12-01
ratios had significantly higher than average E2- ELISA scores relative to other AD stages, a feature that was most significant among those proteins...Figure 3 Significant correlations exist between Braak stage, E2- ELISA score, upregulation in AD and interactions between tau and Abeta These emerge...from a bioinformatic comparison of CSF proteomes Panel A: E2-/E2+ ELISA ratios (shown as percentE2- scores) of CSF exosome fractions taken from
USDA-ARS?s Scientific Manuscript database
An indirect enzyme-linked immunosorbent assay (ELISA) was developed using baculovirus expressed N1 protein from the A/CK/Indonesia/PA/2003 (H5N1) virus. The specificity of the assay was tested with a panel of chicken anti-sera raised against N1 to N9 virus subtypes. The N1-ELISA was specific for t...
Detection of HIV-1 p24 at Attomole Level by Ultrasensitive ELISA with Thio-NAD Cycling
Nakatsuma, Akira; Kaneda, Mugiho; Kodama, Hiromi; Morikawa, Mika; Watabe, Satoshi; Nakaishi, Kazunari; Yamashita, Masakane; Yoshimura, Teruki; Miura, Toshiaki; Ninomiya, Masaki; Ito, Etsuro
2015-01-01
To reduce the window period between HIV-1 infection and the ability to diagnose it, a fourth-generation immunoassay including the detection of HIV-1 p24 antigen has been developed. However, because the commercially available systems for this assay use special, high-cost instruments to measure, for example, chemiluminescence, it is performed only by diagnostics companies and hub hospitals. To overcome this limitation, we applied an ultrasensitive ELISA coupled with a thio-NAD cycling, which is based on a usual enzyme immunoassay without special instruments, to detect HIV-1 p24. The p24 detection limit by our ultrasensitive ELISA was 0.0065 IU/assay (i.e., ca. 10-18 moles/assay). Because HIV-1 p24 antigen is thought to be present in the virion in much greater numbers than viral RNA copies, the value of 10-18 moles of the p24/assay corresponds to ca. 103 copies of the HIV-1 RNA/assay. That is, our ultrasensitive ELISA is chasing the detection limit (102 copies/assay) obtained by PCR-based nucleic acid testing (NAT) with a margin of only one different order. Further, the detection limit by our ultrasensitive ELISA is less than that mandated for a CE-marked HIV antigen/antibody assay. An additional recovery test using blood supported the reliability of our ultrasensitive ELISA. PMID:26098695
A Sandwich ELISA for Adducts of Polycyclic Aromatic Hydrocarbons with Human Serum Albumin1
Chung, Ming Kei; Riby, Jacques; Li, He; Iavarone, Anthony T.; Williams, Evan R.; Zheng, Yuxin; Rappaport, Stephen M.
2010-01-01
Adducts of benzo[α]pyrene-diolepoxide (BPDE)2 with blood nucleophiles have been used as biomarkers of exposure to polycyclic aromatic hydrocarbons (PAHs). The most popular such assay is a competitive ELISA which employs monoclonal antibody 8E11 to detect benzo[α]pyrene tetrols following hydrolysis of BPDE adducts from lymphocyte DNA or human serum albumin (HSA). Here we use 8E11 as the capture antibody in a sandwich ELISA to detect BPDE-HSA adducts directly in 1 mg samples of HSA or 20 μL of serum/plasma. The assay employs an anti-HSA antibody for detection, which is amplified by an avidin/biotinylated horseradish peroxidase complex. The sandwich ELISA has advantages of specificity and simplicity and is about 10 times more sensitive than the competitive ELISA. To validate the assay, HSA samples were assayed from three populations with known high (coke-oven workers), medium (steel-factory control workers), and low (volunteer subjects) PAH exposures (n = 30). The respective geometric mean levels of BPDE-HSA adducts, i.e., 67.8, 14.7 and 1.93 ng/mg HSA (1,010, 220 and 28.9 fmol BPDE equivalents/mg HSA), were significantly different (p < 0.05). The sandwich ELISA will be useful for screening PAH exposures in large epidemiologic studies and can be extended to other adducts for which capture antibodies are available. PMID:20083082
Trindade, Mirta; Nording, Malin; Nichkova, Mikaela; Spinnel, Erik; Haglund, Peter; Last, Michael S.; Gee, Shirley; Hammock, Bruce; Last, Jerold A.; González-Sapienza, Gualberto; Brena, Beatriz M.
2010-01-01
Uncontrolled combustion due to garbage recycling is a widespread activity among slum dwellers in distressed economy countries and has been indicated as a major source of dioxin contamination. However, because of the high cost and complexity of gas chromatography/high-resolution mass spectrometry (GC-HRMS) analysis, the magnitude of the problem remains largely unknown. The present study describes a first approach toward the use of a dioxin antibody-based enzyme-linked immunosorbent assay (ELISA) as the basis for a sustainable, simple, and low-cost monitoring program to assess the toxicological impact of uncontrolled combustion in slums. A panel of 16 samples was analyzed by GC-HRMS and ELISA on split extracts. Close to 20% of the analyzed samples showed dioxin concentrations up to almost twice the guidance level for residential soil in several countries, pointing out the need for performing a large-scale monitoring program. Despite the potential for variations in dioxin congener distribution due to the mixed nature of the incinerated material, there was a good correlation between the toxic equivalents as determined by GC-HRMS and ELISA. Furthermore, an interlaboratory ELISA validation showed that the capacity to perform the dioxin ELISA was successfully transferred between laboratories. It was concluded that the ELISA method performed very well as a screening tool to prioritize samples for instrumental analysis, which allows cutting down costs significantly. PMID:18522475
A plasmonic ELISA for the naked-eye detection of chromium ions in water samples.
Yao, Cuize; Yu, Shiting; Li, Xiuqing; Wu, Ze; Liang, Jiajie; Fu, Qiangqiang; Xiao, Wei; Jiang, Tianjiu; Tang, Yong
2017-02-01
Here, we describe the development of a triangular silver nanoprism (AgNPR) etching-based plasmonic ELISA for the colorimetric determination of Cr(III) levels in environmental water samples. This involved the creation of a novel signal generation system (substrate reaction solution) for a competitive ELISA in which hydrogen peroxide (H 2 O 2 ) is used to etch triangular AgNPRs, inducing a change in color. This is achieved by controlling the H 2 O 2 concentration that remains after degradation by catalase, which is conjugated to the secondary antibody of the ELISA. Because the degree of color change and the shift in the absorption spectrum of the substrate reaction solution are closely correlated with the Cr(III) concentration, this plasmonic ELISA can be used not only for the quantification of Cr(III) concentrations ranging from 3.13 to 50 ng/mL, with a limit of detection (LOD) of 3.13 ng/mL, but also for the visual detection (indicated by a color change from blue to mauve) of Cr(III) with a sensitivity of 6.25 ng/mL by the naked eye. Therefore, the plasmonic ELISA developed in this work represents a new strategy for heavy metal ion detection and has high potential applicability in resource-constrained areas. Graphical Abstract Schematic diagram of triangular silver nanoprism etching-based signal generation system.
Feng, Xia; Ma, Jun-Wu; Sun, Shi-Qi; Guo, Hui-Chen; Yang, Ya-Min; Jin, Ye; Zhou, Guang-Qing; He, Ji-Jun; Guo, Jian-Hong; Qi, Shu-yun; Lin, Mi; Cai, Hu; Liu, Xiang-Tao
2016-01-01
The efficacy of an inactivated foot-and-mouth disease (FMD) vaccine is mainly dependent on the integrity of the foot-and-mouth disease virus (FMDV) particles. At present, the standard method to quantify the active component, the 146S antigen, of FMD vaccines is sucrose density gradient (SDG) analysis. However, this method is highly operator dependent and difficult to automate. In contrast, the enzyme-linked immunosorbent assay (ELISA) is a time-saving technique that provides greater simplicity and sensitivity. To establish a valid method to detect and quantify the 146S antigen of a serotype O FMD vaccine, a double-antibody sandwich (DAS) ELISA was compared with an SDG analysis. The DAS ELISA was highly correlated with the SDG method (R2 = 0.9215, P<0.01). In contrast to the SDG method, the DAS ELISA was rapid, robust, repeatable and highly sensitive, with a minimum quantification limit of 0.06 μg/mL. This method can be used to determine the effective antigen yields in inactivated vaccines and thus represents an alternative for assessing the potency of FMD vaccines in vitro. But it still needs to be prospectively validated by analyzing a new vaccine preparation and determining the proper protective dose followed by an in vivo vaccination-challenge study to confirm the ELISA findings.
Kaundal, Nirmal; Sarkate, Purva; Prakash, Charu; Rishi, Narayan
2017-06-01
Environmental surveillance of polioviruses has been used as an important tool in monitoring circulation of wild polioviruses and/or Vaccine derived polioviruses in sewage samples. It is important to distinguish Sabin like isolates from non-Sabin like; ELISA & dual stage real time RT-PCR have been used for the same. Current study was carried out on sewage isolates to compare ELISA & RT-PCR with sequencing to distinguish Sabin like from non-Sabin like. Out of 468 sewage specimens, 91 (19.44%) were non-polio enteroviruses positive and 377 (80.56%) were polio positive by virus isolation method. A total of 488 polio virus isolates were detected by L20B and RD route which were further subjected to ELISA and RT-PCR. The results were compared with sequencing. On comparison, the specificity of ELISA was only 66.67% in spite of very low sensitivity (3.43%). The sensitivity of RT-PCR was 97.71% which makes it a good primary screening test for detection of non-Sabin like viruses. However, the specificity was only 33.33%. RT-PCR appears to be a sensitive tool for detecting non-Sabin like viruses however; the isolates which are non-Sabin like by RT-PCR may not necessarily be mutated viruses. ELISA cannot be used for differentiation of Sabin likes from non-Sabin likes due to low sensitivity.
Deplazes, P; Alther, P; Tanner, I; Thompson, R C; Eckert, J
1999-02-01
A sandwich enzyme-linked immunosorbent assay (ELISA) for the detection of Echinococcus multilocularis coproantigens (EM-ELISA) was developed with polyclonal rabbit (solid phase) and chicken egg (catching) antibodies that were directed against E. multilocularis coproantigens and somatic worm antigens, respectively. In experimentally infected dogs and cats, coproantigens were first detectable 6-17 days postinfection (PI) in samples of 8 dogs (worm burdens at necropsy: 6,330-43,200) and from 11 days PI onward in samples of 5 cats infected with 20-6,833 worms. After anthelmintic treatment of 4 dogs and 5 cats at day 20 PI, coproantigen excretion disappeared within 3-5 days. The sensitivity of the ELISA was 83.6% in 55 foxes infected with 4-60,000 E. multilocularis, but reached 93.3% in the 45 foxes harboring more than 20 worms. The EM-ELISA was used in surveys of "normal" dog and cat populations in Switzerland. Among 660 dogs and 263 cats, 5 dogs and 2 cats exhibited a positive reaction. In 2 of these dogs (0.30%) and 1 cat (0.38%), intestinal E. multilocularis infections were confirmed by necropsy, polymerase chain reaction PCR, or both. The specificites of the ELISA in these groups were found to be 99.5% and 99.6%, respectively, if positive ELISA results that could not be confirmed by other methods were classified as "false positive" reactions.
Adaptive Focused Acoustics (AFA) Improves the Performance of Microtiter Plate ELISAs.
Green, David J; Rudd, Edwin A; Laugharn, James A
2014-08-01
We investigated the use of Adaptive Focused Acoustics (AFA) technology to improve the performance of microtiter plate enzyme-linked immunosorbent assays (ELISAs). Experiments were performed with commercially available AFA instrumentation and off-the-shelf 96-well microtiter plate sandwich ELISAs. AFA was applied over a range of acoustic energies, temperatures, and durations to the antigen/antibody binding step of an ELISA for measuring HIV-1 p24 in tissue culture samples. AFA-mediated antigen/antibody binding was enhanced up to 2-fold over passive binding at comparable temperatures and was superior or comparable at low temperature (8-10 °C) to passive binding at 37 °C. Lower nonspecific binding (NSB), lower inter- and intra-assay coefficients of variation (CVs), higher Z' factors, and lower limits of detection (LODs) were measured in AFA-mediated assays compared with conventional passive binding. In a more limited study, AFA enhancement of antigen/antibody binding and lower NSB was measured in an ELISA for measuring IGFBP-3 in human plasma. We conclude from this study that application of AFA to antigen/antibody binding steps in microtiter plate ELISAs can enhance key assay performance parameters, particularly Z' factors and LODs. These features render AFA-mediated binding assays potentially more useful in applications such as high-throughput screening and in vitro diagnostics than assays processed with conventional passive antigen/antibody binding steps. © 2014 Society for Laboratory Automation and Screening.
Feng, Xia; Ma, Jun-Wu; Sun, Shi-Qi; Guo, Hui-Chen; Yang, Ya-Min; Jin, Ye; Zhou, Guang-Qing; He, Ji-Jun; Guo, Jian-Hong; Qi, Shu-yun; Lin, Mi; Cai, Hu; Liu, Xiang-Tao
2016-01-01
The efficacy of an inactivated foot-and-mouth disease (FMD) vaccine is mainly dependent on the integrity of the foot-and-mouth disease virus (FMDV) particles. At present, the standard method to quantify the active component, the 146S antigen, of FMD vaccines is sucrose density gradient (SDG) analysis. However, this method is highly operator dependent and difficult to automate. In contrast, the enzyme-linked immunosorbent assay (ELISA) is a time-saving technique that provides greater simplicity and sensitivity. To establish a valid method to detect and quantify the 146S antigen of a serotype O FMD vaccine, a double-antibody sandwich (DAS) ELISA was compared with an SDG analysis. The DAS ELISA was highly correlated with the SDG method (R2 = 0.9215, P<0.01). In contrast to the SDG method, the DAS ELISA was rapid, robust, repeatable and highly sensitive, with a minimum quantification limit of 0.06 μg/mL. This method can be used to determine the effective antigen yields in inactivated vaccines and thus represents an alternative for assessing the potency of FMD vaccines in vitro. But it still needs to be prospectively validated by analyzing a new vaccine preparation and determining the proper protective dose followed by an in vivo vaccination-challenge study to confirm the ELISA findings. PMID:26930597
Selection of phage-displayed peptides for the detection of imidacloprid in water and soil.
Liu, Zhiping; Liu, Jianfeng; Wang, Kai; Li, Wenhui; Shelver, Weilin L; Li, Qing X; Li, Ji; Xu, Ting
2015-09-15
Imidacloprid is the most widely used neonicotinoid insecticide in the world and shows widespread environment and human exposures. A phage clone designated L7-1 that selectively binds to imidacloprid was selected from a commercial phage display library containing linear 7-mer randomized amino acid residues. Using the clone L7-1, a competitive enzyme-linked immunosorbent assay (ELISA) for imidacloprid was developed. The half-maximum signal inhibition concentration (IC50) and the limit of detection (LOD) of the phage ELISA for imidacloprid were 96 and 2.3 ng ml(-1), respectively. This phage ELISA showed relatively low cross-reactivity with all of the tested compounds structurally similar to imidacloprid, less than 2% with the exception of 6-chloronicotinic acid, a metabolite of imidacloprid that showed 11.5%. The average recoveries of the phage ELISA for imidacloprid in water and soil samples were in the ranges of 74.6 to 86.3% and 72.5 to 93.6%, respectively. The results of the competitive phage ELISA for imidacloprid in the fortified samples agreed well with those of a high-performance liquid chromatography (HPLC) method. The simple phage-displayed peptide technology has been proven to be a convenient and efficient method for the development of an alternative format of ELISA for small molecules. Copyright © 2015 Elsevier Inc. All rights reserved.
Bhattacharya, D; Bhattacharya, R; Dhar, T K
1999-11-19
In an earlier communication we have described a novel signal amplification technology termed Super-CARD, which is able to significantly improve antigen detection sensitivity in conventional Dot-ELISA by approximately 10(5)-fold. The method utilizes hitherto unreported synthesized electron rich proteins containing multiple phenolic groups which, when immobilized over a solid phase as blocking agent, markedly increases the signal amplification capability of the existing CARD method (Bhattacharya, R., Bhattacharya, D., Dhar, T.K., 1999. A novel signal amplification technology based on catalyzed reporter deposition and its application in a Dot-ELISA with ultra high sensitivity. J. Immunol. Methods 227, 31.). In this paper we describe the utilization of this Super-CARD amplification technique in ELISA and its applicability for the rapid determination of aflatoxin B(1) (AFB(1)) in infected seeds. Using this method under identical conditions, the increase in absorbance over the CARD method was approximately 400%. The limit of detection of AFB(1) by this method was 0.1 pg/well, the sensitivity enhancement being 5-fold over the optimized CARD ELISA. Furthermore, the total incubation time was reduced to 16 min compared to 50 min for the CARD method. Assay specificity was not adversely affected and the amount of AFB(1) measured in seed extracts correlated well with the values obtained by conventional ELISA.
A new ELISA for determination of potency in snake antivenoms.
Rial, A; Morais, V; Rossi, S; Massaldi, H
2006-09-15
A competitive ELISA for potency determination of bothropic equine antivenom was developed and compared to the conventional in vivo ED(50) assay, with the aim of partially substituting the in vivo assay in the monitoring of antivenom immunoglobulin levels. On this purpose, blood samples were taken at different times during and after the immunization protocol of the lot of horses used for production of snake antivenom at the Instituto de Higiene, Uruguay. Both the competitive ELISA and the ED(50) assay were performed on those samples. In addition, a group of five commercial pepsin-digested antivenoms were tested by both methods. A significant (P<0.001) correlation (Pearson's r=0.957) was found between the ELISA titres and the corresponding ED(50) values, indicating that the in vitro test can estimate the neutralizing antibody capacity of the sera as well as the in vivo assay. By means of this new ELISA, it was found that the immunized animals maintained good venom antibody titres, in the order of 20-50% of the maximum achieved, even 10 month after the end of the immunization schedule. The main advantage of our ELISA design is its ability to correctly estimate the neutralization capacity of crude hyperimmune plasma and antivenom sera independently of their antibody composition in terms of whole IgG or F(ab')(2) fragment.
Development of an ELISA for the Detection of Azaspiracids.
Samdal, Ingunn A; Løvberg, Kjersti E; Briggs, Lyn R; Kilcoyne, Jane; Xu, Jianyan; Forsyth, Craig J; Miles, Christopher O
2015-09-09
Azaspiracids (AZAs) are a group of biotoxins that cause food poisoning in humans. These toxins are produced by small marine dinoflagellates such as Azadinium spinosum and accumulate in shellfish. Ovine polyclonal antibodies were produced and used to develop an ELISA for quantitating AZAs in shellfish, algal cells, and culture supernatants. Immunizing antigens were prepared from synthetic fragments of the constant region of AZAs, while plate coating antigen was prepared from AZA-1. The ELISA provides a sensitive and rapid analytical method for screening large numbers of samples. It has a working range of 0.45-8.6 ng/mL and a limit of quantitation for total AZAs in whole shellfish at 57 μg/kg, well below the maximum permitted level set by the European Commission. The ELISA has good cross-reactivity to AZA-1-10, -33, and -34 and 37-epi-AZA-1. Naturally contaminated Irish mussels gave similar results whether they were cooked or uncooked, indicating that the ELISA also detects 22-carboxy-AZA metabolites (e.g., AZA-17 and AZA-19). ELISA results showed excellent correlation with LC-MS/MS analysis, both for mussel extract spiked with AZA-1 and for naturally contaminated Irish mussels. The assay is therefore well suited to screening for AZAs in shellfish samples intended for human consumption, as well as for studies on AZA metabolism.
Chen, Rui; Huang, Xiaolin; Xu, Hengyi; Xiong, Yonghua; Li, Yanbin
2015-12-30
Plasmonic enzyme-linked immunosorbent assay (pELISA) based on catalase (CAT)-mediated gold nanoparticle growth exhibits ultrahigh sensitivity for detecting disease-related biomarkers using sandwich formats. However, the limit of detection (LOD) of this strategy for Listeria monocytogenes is only around 10(3) CFU/mL, which considerably exceeds the amount of L. monocytogenes commonly present in food products (<100 CFU/g). Herein, we report an improved pELISA method for detection of L. monocytogenes at ultralow concentrations with the sandwich formats using silica nanoparticles carrying poly(acrylic acid) brushes as a "CAT container" to increase enzyme loading for enhancing the detection signal. Under optimal conditions, the proposed pELISA exhibits good specificity and excellent sensitivity for L. monocytogenes with a LOD of 8 × 10(1) CFU/mL in 0.01 M phosphate-buffered saline, via a reaction that can be discriminated by the naked eye. The LOD obtained by this method was 2 and 5 orders of magnitude lower than that of conventional CAT-based pELISA and horseradish peroxidase (HRP)-based conventional ELISA, respectively. Coupled with large-volume immunomagnetic separation, the LOD for L. monocytogenes-spiked lettuce samples reached 8 × 10(1) CFU/g. The improved pELISA also exhibited a great potential in detecting a single cell of L. monocytogenes in 100 μL of solution.
Singh, Harpal; Shimojima, Masayuki; Fukushi, Shuetsu; Le Van, An; Sugamata, Masami; Yang, Ming
2015-01-01
Enzyme-linked Immunosorbent Assay or ELISA -based diagnostics are considered the gold standard in the demonstration of various immunological reaction including in the measurement of antibody response to infectious diseases and to support pathogen identification with application potential in infectious disease outbreaks and individual patients' treatment and clinical care. The rapid prototyping of ELISA-based diagnostics using available 3D printing technologies provides an opportunity for a further exploration of this platform into immunodetection systems. In this study, a '3D-Well' was designed and fabricated using available 3D printing platforms to have an increased surface area of more than 4 times for protein-surface adsorption compared to those of 96-well plates. The ease and rapidity in designing-product development-feedback cycle offered through 3D printing platforms provided an opportunity for its rapid assessment, in which a chemical etching process was used to make the surface hydrophilic followed by validation through the diagnostic performance of ELISA for infectious disease without modifying current laboratory practices for ELISA. The higher sensitivity of the 3D-Well (3-folds higher) compared to the 96-well ELISA provides a potential for the expansion of this technology towards miniaturization platforms to reduce time, volume of reagents and samples needed for laboratory or field diagnosis of infectious diseases including applications in other disciplines.
Waner, T; Mazar, S; Nachmias, E; Keren-Kornblatt, E; Harrus, S
2003-05-10
A dot ELISA for the detection of immunoglobulin M (IgM) antibodies to canine distemper virus (CDC) and canine parvovirus (CPV) was assessed. The titres of IgM antibodies to CDV and CPV in 100 dogs were measured by the Immunocomb ELISA kit and compared with the results derived from the immunofluorescence assay (IFA). There was a strong correlation between the results of the dot ELISA technique and the IFA (P < 0.001). The dot ELISA kit was also used to assess the changes in the levels of immunoglobulin G (IgG) and IgM antibodies to CPV and CDV in 10 puppies vaccinated with a polyvalent vaccine. High levels of IgM antibodies to CPV were first detected seven days after they were vaccinated, and after nine days all the pups had high titres of IgG antibodies to CPV. High levels of IgM antibodies to CDV were detected after nine days and the highest average titres were recorded after 12 days. IgG antibodies to CDV were present from nine days after vaccination.
Lardeux, Frédéric; Torrico, Gino; Aliaga, Claudia
2016-07-04
In ELISAs, sera of individuals infected by Trypanosoma cruzi show absorbance values above a cut-off value. The cut-off is generally computed by means of formulas that need absorbance readings of negative (and sometimes positive) controls, which are included in the titer plates amongst the unknown samples. When no controls are available, other techniques should be employed such as change-point analysis. The method was applied to Bolivian dog sera processed by ELISA to diagnose T. cruzi infection. In each titer plate, the change-point analysis estimated a step point which correctly discriminated among known positive and known negative sera, unlike some of the six usual cut-off formulas tested. To analyse the ELISAs results, the change-point method was as good as the usual cut-off formula of the form "mean + 3 standard deviation of negative controls". Change-point analysis is therefore an efficient alternative method to analyse ELISA absorbance values when no controls are available.
Chisi, Songelwayo L; Marageni, Yoanda; Naidoo, Prebashni; Zulu, Gloria; Akol, George W; Van Heerden, Henriette
2017-02-28
The diagnostic sensitivity (DSe) of the Rose Bengal test (RBT), the complement fixation test (CFT), the serum agglutination test (SAT), the competitive enzyme-linked immunosorbent assay (cELISA) and the indirect ELISA (iELISA) were determined in naturally infected cattle in KwaZulu-Natal province of South Africa with known infectious status from culture (gold standard). Natural brucellosis infection status of animals was determined by culturing and identification of Brucella abortus biovar 1 from abomasal fluid, milk, hygroma fluid, lymph nodes or uterine discharges samples. The diagnostic specificity (DSp) of the tests mentioned above was determined using samples from known negative herds. There was no statistically significant difference between the tests in their ability to diagnose brucellosis. The RBT and iELISA had the highest DSe of 95.8%, whereas RBT and CFT had the highest DSp of 100%. In South African laboratories, the RBT and CFT serological tests are used, because of the cost efficacy of CFT when compared to the less labour intensive but more expensive iELISA.
Hotomi, Muneki; Togawa, Akihisa; Kono, Masamitsu; Sugita, Gen; Sugita, Rinya; Fujimaki, Yutaka; Kamide, Yosuke; Uchizono, Akihiro; Kanesada, Keiko; Sawada, Shoichi; Okitsu, Naohiro; Masuda, Hisayo; Tanaka, Hideaki; Tanaka, Yumi; Yamanaka, Noboru
2013-01-01
An enzyme-linked immunosorbent assay specific to outer membrane protein P6 (P6-ELISA) was applied for detecting Haemophilus influenzae in middle ear fluids (MEFs) from acute otitis media (AOM) patients and in nasopharyngeal secretions (NPSs) from acute rhinosinusitis patients. P6-ELISA had a sensitivity of 83.3% for MEFs and 71.5% for NPSs and a specificity of 85.6% for MEFs and 92.5% for NPSs, respectively. Real-time PCR exhibited significant differences in the number of ompP1 gene copies among samples determined by P6-ELISA to be positive and negative for H. influenzae. However, because the P6-ELISA test has the reactivity in Haemophilus species include two commensals H. haemolyticus and H. parainfluenzae, it is thus a weak method in order to detect only NTHi correctly. Consequently, diagnosis using the P6-ELISA should be based on an overall evaluation, including the results of other related examinations and clinical symptoms to prevent misleading conclusions in clinical setting. PMID:24015192
Abd-Alla, M D; Wahib, A A; Ravdin, J I
2000-05-01
We performed a prospective field study in the village of Kafer Daoud in Menofia, Egypt to compare the fecal culture method with enzyme linked immuno assay (ELISA) for detection of 170 kDa lectin antigen in feces for diagnosis of asymptomatic Entamoeba histolytica and Entamoeba dispar infection. All subjects with E. histolytica or E. dispar infection detected by culture also had positive ELISA for amebic antigen in their feces and an additional 57 Entameoba infections missed by culture were detected by ELISA (P < 0.001 compared to culture). The presence of fecal anti-lectin IgA antibodies and serum anti-LC3 (recombinant cysteine-rich lectin protein) IgG antibodies were positive predictors for E. histolytica infection (P < 0.03). Of interest, infection with Trichomonas hominis but not Blastocystis hominis was positively associated with E. histolytica infection (P < 0.05). In conclusion, ELISA for detection of fecal lectin antigen is a more sensitive method than fecal culture for detecting asymptomatic E. histolytica infection.
He, Jinxin; Wang, Yuan; Sun, Shiqi; Zhang, Xiaoying
2015-11-01
Immunoglobulin Y (IgY) antibodies were generated against canine parvovirus virus-like particles (CPV-VLPs) antigen using chickens. Anti-CPV-VLPs-IgY was extracted from hen egg yolk and used for developing enzyme-linked immunosorbent assay (ELISA) and immunochromatographic assay (ICA) for the detection of CPV in dog feces. The cutoff negative values for anti-CPV-VLPs-IgY were determined using negative fecal samples (already confirmed by polymerase chain reaction [PCR]). In both ELISA and ICA, there was no cross-reaction with other diarrheal pathogens. Thirty-four fecal samples were collected from dogs with diarrhea, of which 26.47% were confirmed as CPV-positive samples by PCR, while 29.41% and 32.35% of the samples were found to be positive by ELISA and ICA, respectively. The developed ELISA and ICA exhibited 97.06% and 94.12% conformity with PCR. Higher sensitivity and specificity were observed for IgY-based ELISA and ICA. Thus, they could be suitable for routine use in the diagnosis of CPV in dogs.
Kidd, J A; Ross, P; Buntzman, A S; Hess, P R
2015-06-01
Resistance to Escherichia coli l-asparaginase in canine lymphoma occurs frequently with repeated administration, a phenomenon often attributed, without substantiation, to the induction of neutralizing antibodies. To test the hypothesis that treated dogs develop antibodies against the drug, we created an enzyme-linked immunosorbent assay (ELISA) to measure plasma anti-asparaginase immunoglobulin G responses. Using samples from dogs that had received multiple doses, specific reactivity against l-asparaginase was demonstrated, while naïve patients' samples were negative. The optimized ELISA appeared sensitive, with endpoint titers >1 600 000 in positive control dogs. Intra- and inter-assay coefficients of variation were 3.6 and 14.5%. The assay was supported by the observation that ELISA-positive plasma could immunoprecipitate asparaginase activity. When clinical patients were evaluated, 3/10 dogs developed titers after a single injection; with repeated administration, 4/7 dogs were positive. l-asparaginase antibodies showed reduced binding to the PEGylated drug formulation. The ELISA should prove useful in investigating the potential correlation of antibody responses with resistance. © 2012 Blackwell Publishing Ltd.
Kidd, Jason A.; Ross, Peter; Buntzman, Adam S.; Hess, Paul R.
2012-01-01
Resistance to E. coli L-asparaginase in canine lymphoma occurs frequently with repeated administration, a phenomenon often attributed, without substantiation, to the induction of neutralizing antibodies. To test the hypothesis that treated dogs develop antibodies against the drug, we created an ELISA to measure plasma anti-asparaginase IgG responses. Using samples from dogs that had received multiple doses, specific reactivity against L-asparaginase was demonstrated, while naïve patients’ samples were negative. The optimized ELISA appeared sensitive, with endpoint titers >1,600,000 in positive control dogs. Intra- and inter-assay coefficients of variation were 3.6 and 14.5%. The assay was supported by the observation that ELISA-positive plasma could immunoprecipitate asparaginase activity. When clinical patients were evaluated, 3/10 dogs developed titers after a single injection; with repeated administration, 4/7 dogs were positive. L-asparaginase antibodies showed reduced binding to the PEGylated drug formulation. The ELISA should prove useful in investigating the potential correlation of antibody responses with resistance. PMID:23253146
Robinson, Carl; Steward, Karen F; Potts, Nicola; Barker, Colin; Hammond, Toni-ann; Pierce, Karen; Gunnarsson, Eggert; Svansson, Vilhjálmur; Slater, Josh; Newton, J Richard; Waller, Andrew S
2013-08-01
The detection of anti-Streptococcus equi antibodies in the blood serum of horses can assist with the identification of apparently healthy persistently infected carriers and the prevention of strangles outbreaks. The aim of the current study was to use genome sequencing data to develop an indirect enzyme linked immunosorbent assay (iELISA) that targets two S. equi-specific protein fragments. The sensitivity and specificity of the antigen A and antigen C iELISAs were compared to an SeM-based iELISA marketed by IDvet - diagnostic Vétérinaire (IDvet). Individually, each assay compromised specificity in order to achieve sufficient sensitivity (SeM iELISA had a sensitivity of 89.9%, but a specificity of only 77.0%) or sensitivity to achieve high specificity. However, combining the results of the antigen A and antigen C iELISAs permitted optimisation of both sensitivity (93.3%) and specificity (99.3%), providing a robust assay for the identification of horses exposed to S. equi. Copyright © 2013 Elsevier Ltd. All rights reserved.
Hotomi, Muneki; Togawa, Akihisa; Kono, Masamitsu; Sugita, Gen; Sugita, Rinya; Fujimaki, Yutaka; Kamide, Yosuke; Uchizono, Akihiro; Kanesada, Keiko; Sawada, Shoichi; Okitsu, Naohiro; Masuda, Hisayo; Tanaka, Hideaki; Tanaka, Yumi; Yamanaka, Noboru
2013-01-01
An enzyme-linked immunosorbent assay specific to outer membrane protein P6 (P6-ELISA) was applied for detecting Haemophilus influenzae in middle ear fluids (MEFs) from acute otitis media (AOM) patients and in nasopharyngeal secretions (NPSs) from acute rhinosinusitis patients. P6-ELISA had a sensitivity of 83.3% for MEFs and 71.5% for NPSs and a specificity of 85.6% for MEFs and 92.5% for NPSs, respectively. Real-time PCR exhibited significant differences in the number of ompP1 gene copies among samples determined by P6-ELISA to be positive and negative for H. influenzae. However, because the P6-ELISA test has the reactivity in Haemophilus species include two commensals H. haemolyticus and H. parainfluenzae, it is thus a weak method in order to detect only NTHi correctly. Consequently, diagnosis using the P6-ELISA should be based on an overall evaluation, including the results of other related examinations and clinical symptoms to prevent misleading conclusions in clinical setting.
2004-01-01
Abstract A serologic survey was conducted in yearling cattle imported into Alberta feedlots from Montana during October 2001 to estimate the prevalence of antibodies to bluetongue virus (BTV) and Anaplasma marginale in Montana yearling cattle. The apparent prevalence of antibodies to BTV when the competitive enzyme-linked immunosorbent assay (cELISA) was used was 0.37% (21/5608). Test positive cELISA samples were also all positive when tested by virus neutralization (VN) and they reacted to 1 or more BTV serotypes, including 2, 10, 11, 13, and 17. The apparent prevalence of antibodies to A. marginale when a recombinant cELISA (rcELISA) was used with a positive cutoff at 30% inhibition was 1.93% (108/5608). When the rcELISA positive cutoff was at 42% inhibition, the apparent prevalence was 0.73% (41/5608). After the reported sensitivity and specificity of the test had been accounted for, the A. marginale antibody results were consistent with a population that was either free of exposure or had a very low prevalence for A. marginale. PMID:15283518
Zaer, F; Metz, S; Scornik, J C
1997-01-15
The enzyme-linked immunosorbent assay (ELISA) using HLA class I molecules purified from pooled platelets has the potential to detect HLA antibodies with increased efficiency without sacrificing sensitivity or specificity. This test, which was originally developed in our institution, has been independently validated by recent studies and is now commercially available. We now present evidence of its usefulness as a routine HLA antibody screening test for renal transplant patients. A total of 515 patients were tested monthly by ELISA (13.9 tests/patient) and by antiglobulin-enhanced panel reactivity (6.3 tests/patient). In patients found to be unsensitized, the incidence of false-positive results was less for ELISA than for the panel studies. In patients who were highly sensitized, both tests performed equally well, whereas discordant results were registered mainly in cases of mild sensitization. Because 66% of our patients were not sensitized, the ELISA was effective in reducing the number of more involved tests aimed at characterizing the antibodies. These results provide a foundation to use the pooled platelet HLA ELISA on a routine basis for HLA antibody screening.
Applicability of ELISA-based Determination of Pesticides for Groundwater Quality Monitoring
NASA Astrophysics Data System (ADS)
Tsuchihara, Takeo; Yoshimoto, Shuhei; Ishida, Satoshi; Imaizumi, Masayuki
The principals and procedures of ELISA (Enzyme-linked Immunosorbent Assay)-based determination of pesticides (Fenitrothion) in environmental samples were reviewed, and the applicability of the ELISA method for groundwater quality monitoring were validated through the experimental tracer tests in soil columns and the field test in Okinoerabu Island. The test results showed that the ELISA method could be useful not only for screening but also for quantitative analysis of pesticides. In the experimental tracer tests in soil columns, the retardation of pesticides leaching compared with conservative tracers were observed. In the field test, the contamination of the pesticide was detected in groundwater samples in Okinoerabu Island, even though the targeted pesticide was considered to be applied to the upland field 4 months ago. In order to investigate the transport and fate of pesticides in groundwater taking into account retardation from the field to groundwater table and the residue in groundwater, continuous observations of pesticides in groundwater are in a strong need, and the ELISA method is applicable to the long-term quality groundwater monitoring.
Design of a compact disk-like microfluidic platform for enzyme-linked immunosorbent assay.
Lai, Siyi; Wang, Shengnian; Luo, Jun; Lee, L James; Yang, Shang-Tian; Madou, Marc J
2004-04-01
This paper presents an integrated microfluidic device on a compact disk (CD) that performs an enzyme-linked immunosorbent assay (ELISA) for rat IgG from a hybridoma cell culture. Centrifugal and capillary forces were used to control the flow sequence of different solutions involved in the ELISA process. The microfluidic device was fabricated on a plastic CD. Each step of the ELISA process was carried out automatically by controlling the rotation speed of the CD. The work on analysis of rat IgG from hybridoma culture showed that the microchip-based ELISA has the same detection range as the conventional method on the 96-well microtiter plate but has advantages such as less reagent consumption and shorter assay time over the conventional method.
Amperometric IFN-γ immunosensors with commercially fabricated PCB sensing electrodes.
Moschou, Despina; Greathead, Louise; Pantelidis, Panagiotis; Kelleher, Peter; Morgan, Hywel; Prodromakis, Themistoklis
2016-12-15
Lab-on-a-Chip (LoC) technology has the potential to revolutionize medical Point-of-Care diagnostics. Currently, considerable research efforts are focused on innovative production technologies that will make commercial upscaling of lab-on-chip products financially viable. Printed circuit board (PCB) manufacturing techniques have several advantages in this field. In this paper we focus on transferring a complete IFN-γ enzyme-linked immune-sorbent assay (ELISA) onto a commercial PCB electrochemical biosensing platform, We adapted a commercially available ELISA to detect the enzyme product TMB/H2O2 using amperometry, successfully reproducing the colorimetry-obtained ELISA standard curve. The results demonstrate the potential for the integration of these components into an automated, disposable, electronic ELISA Lab-on-PCB diagnostic platform. Copyright © 2016 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Yu, An; Geng, Tingting; Fu, Qiang; Chen, Chao; Cui, Yali
2007-04-01
Using GoldMag (Fe3O4/Au) nanoparticles as a carrier, a biotin-avidin amplified ELISA was developed to detect hepatitis B surface antigen (HBsAg). A specific antibody was labeled with biotin and then used to detect the antigen with an antibody coated on GoldMag nanoparticles by a sandwich ELISA assay. The results showed that 5 mol of biotin were surface bound per mole of antibody. The biotin-avidin amplified ELISA assay has a higher sensitivity than that of the direct ELISA assay. There is 5-fold difference between HBsAg positive and negative serum even at dilution of 1:10000, and the relative standard deviation of the parallel positive serum at dilution of 1:4000 is 5.98% (n=11).
Enzyme-Linked Immunosorbent Assay (ELISA).
Konstantinou, George N
2017-01-01
Food allergy is a public health concern especially after recognizing its constantly increased prevalence and severity. Despite careful reading of food ingredient statements, food allergic individuals may experience reactions caused by "hidden", "masked", or "contaminated" proteins that are known major allergens. Many techniques have been developed to detect even small traces of food allergens, for clinical or laboratory purposes. Enzyme-linked immunosorbent assay (ELISA) is one of the best validated and most routinely used immunoassay in allergy research, in allergy diagnosis in allergy-related quality control in various industries. Although as a technique it has been implemented for the last 45 years, the evolution in biochemistry allowed the development of ultrasensitive ELISA variations that are capable of measuring quantities in the scale of picograms, rendering ELISA attractive, robust, and very famous.
Hou, Fenxia; Xing, Caihong; Li, Bin; Cheng, Juan; Chen, Wei; Zhang, Man
2015-01-01
Allergic contact dermatitis (ACD) is a skin disease characterized by eczema and itching. A considerable proportion of chemicals induce ACD in humans. More than 10,000 substances should be tested for skin sensitization potential under the Registration, Evaluation, Authorization and Restriction of Chemical substances (REACH) regulation. The Local Lymph Node Assay (LLNA) has been designated as the first-choice in vivo assay for sensitization testing by REACH. The LLNA:BrdU-ELISA is a validated non-radioactive modification to the LLNA. For both the LLNA and the LLNA:BrdU-ELISA, CBA/JN mouse is the preferred mouse strain recommended in the regulatory guidelines. However, the availability of CBA/JN mouse in China is only limited to a few animal suppliers, which makes the mouse difficult to obtain. BALB/c mouse, which is widely commercially available, is considered for alternative use but it can only be used in the assay after it has been evaluated by formal validation study. Thus, a validation study was conducted in our laboratory to determine if BALB/c mouse could also be used in the LLNA:BrdU-ELISA. Forty-three test substances including 32 LLNA sensitizers and 11 LLNA non-sensitizers, their vehicles and each concentration used were the same as that used in the formal validation study for the LLNA:BrdU-ELISA using CBA/JN mouse. Female BALB/c mice of 8-10 weeks old were randomly allocated to groups (four mice per group). The test substance (25 μl) or the vehicle alone was applied to the dorsum of both ears daily for 3 consecutive days. A single intraperitoneal injection of 0.5 ml of BrdU (10mg/ml) solution was given on day 5. On day 6, a pair of auricular lymph nodes from each mouse was excised, weighed and stored at -20°C until BrdU-ELISA was conducted. This validation study for the LLNA:BrdU-ELISA using BALB/c mouse correctly identified 30 of 31 sensitizers and 8 of 11 non-sensitizers. The accuracy, sensitivity, specificity, false positive rate, false negative rate, positive predictivity values and negative predictivity values in this study, which could indicate the performance of the LLNA:BrdU-ELISA using BALB/c mouse, were not different statistically from that of the validation study for the LLNA:BrdU-ELISA using CBA/JN mouse. This validation study indicates that BALB/c mouse could be used alternatively in the LLNA:BrdU-ELISA for the prediction of the skin sensitizing potential of chemicals. Copyright © 2015 Elsevier Inc. All rights reserved.
Elverdal, P L; Jørgensen, C S; Krogfelt, K A; Uldum, S A
2013-08-01
The aim of this study was to evaluate the performance of an in-house ELISA for the diagnosis of Legionnaires' disease (LD) by detection of IgM and IgG antibodies against Legionella (L.) pneumophila serogroups (sg) 1, 3 and 6. The evaluation was done throughout a two-year period in a diagnostic routine laboratory. Furthermore, the sensitivity of four different methods, the in-house L. pneumophila antibody test (ELISA), the urinary antigen test (Binax® EIA), an in-house PCR and culture, both alone and in combination was evaluated. From 2008 to 2010, 12,158 serum samples from 10,503 patients were analysed. During the same period, 361 cases of laboratory-confirmed LD cases were recorded in Denmark, but of these only 113 had a serum sample examined. The positive predictive value of the in-house ELISA was calculated to be 12.8 and the negative predictive value was 99.6, using only the confirmed LD cases as true positives. The sensitivity of the in-house ELISA for the detection of IgM and IgG antibodies in the confirmed LD cases was 61% and 36%, respectively. By combining the two ELISA assays the sensitivity increased to 66%. The sensitivity of the Legionella urinary antigen test (Binax® EIA) was 63%, of the in-house PCR 87% and of culture 69%. When all the different methods were combined, a higher sensitivity was calculated--for in-house ELISA (IgM+IgG) and Binax® EIA 91%, in-house ELISA (IgM+IgG) and in-house PCR 93%, in-house ELISA (IgM+IgG) and culture 93%, Binax® EIA and in-house PCR 79%, Binax® EIA and culture 68% and in-house PCR and culture 94%. This study confirms that the detection of IgG and IgM antibodies by ELISA is an important diagnostic tool, also during the initial phase of the disease. Furthermore, we showed that LD in Denmark with or without serum samples collected exhibits the same age and sex distribution and epidemiology, as in the rest of Europe, i.e., mostly men are infected, infections are mostly community acquired, followed by infection from travelling abroad. Apart from patients with notified LD, the patients investigated by serology were evenly distributed in all age groups; there was only a slightly higher ratio of men tested for "atypical pneumonia" in the serology laboratory. Copyright © 2013 Elsevier B.V. All rights reserved.
78 FR 35290 - Government-Owned Inventions; Availability for Licensing
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-12
... tissues. NIH researchers have developed ELISA assays to quantify the amount of midkine and pleiotrophin...-available midkine or pleiotrophin antibodies. Assay relies on proven ELISA detection technology. Development...
... serology is performed for their patients . 11 Several ELISA-based serologic tests are FDA approved and available ... The most commonly used test, HerpeSelect HSV-2 Elisa might be falsely positive at low index values ( ...
Burki, Umar; Straub, Volker
2017-01-01
Determining the concentration of oligonucleotide in biological samples such as tissue lysate and serum is essential for determining the biodistribution and pharmacokinetic profile, respectively. ELISA-based assays have shown far greater sensitivities compared to other methods such as HPLC and LC/MS. Here, we describe a novel ultrasensitive hybridization-based ELISA method for quantitating morpholino oligonucleotides in mouse tissue lysate and serum samples. The assay has a linear detection range of 5-250 pM (R2 > 0.99).
2017-12-01
each group), collecting the sera at weekly intervals and measuring the antibody titers by ELISA and flow cytometry. 2 October 2016 100 percent...collected at weekly intervals and was used for measuring the antibody titers by ELISA using the full length extracellular domain of MICA as capture...antibodies that bind to MICA on tumor cell surface. A. Elisa to determine the antibody titers in mice vaccinated with MICA vaccine consisting of 50µg
Potential Therapeutic Use of Relaxin in Healing Cranial Bone Defects
2017-09-01
to measure circulating concentrations of relaxin during the infusion by ELISA ; 3. sacrifice the mice at 10-12 days after cranial defect; 4. fix the...osmotic pump for 10-12 days, and to measure circulating concentrations of relaxin during the infusion by ELISA . Values of 0.35, 0.69, 1.61, 0.66, 1.99...vehicle-infused mice, because in our previous work, none was detected. This makes sense, because the ELISA we use does not detect mouse relaxin
Sandwich ELISA Microarrays: Generating Reliable and Reproducible Assays for High-Throughput Screens
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gonzalez, Rachel M.; Varnum, Susan M.; Zangar, Richard C.
The sandwich ELISA microarray is a powerful screening tool in biomarker discovery and validation due to its ability to simultaneously probe for multiple proteins in a miniaturized assay. The technical challenges of generating and processing the arrays are numerous. However, careful attention to possible pitfalls in the development of your antibody microarray assay can overcome these challenges. In this chapter, we describe in detail the steps that are involved in generating a reliable and reproducible sandwich ELISA microarray assay.
Novel Small Molecule Inhibitor of Tyk2: Lucrative Therapeutic Target in Lupus
2017-09-01
collected and analyzed by ELISA . mg/kg of SAR20351 (n=12) or vehicle respectively (n=8) for each group. The animals were treated for a total of six...populations in either of the mouse strains. We also performed ELISA on serum collected from these animals at the end of the 6-week study and found...was collected and analyzed by ELISA . MRL/lpr mice is genetically deficient in Fas receptor where immune cells fail to undergo apoptosis and results
A Novel Therapy for Inflammatory Bowel Disease-Dual Regulatory T-Cell Programming
2017-08-01
Subtask 1: to determine 1,25(OH)2D concentration by ELISA in the dLNs following subcutaneous infusion of the different DCs. 1-3 Subtask 2: to...Achieved: 1. Subtask-1: In one experiment, we failed to detect a significant amount of 1,25(OH)2D by ELISA in the dLNs following subcutaneous...injections of the different DCs. Potential reasons include: 1) the ELISA method was not sufficiently sensitive; 2) we had a problem extracting the
Diogenite-like Features in the Spitzer IRS (5-35 micrometers) Spectrum of 956 ELISA
NASA Technical Reports Server (NTRS)
Lim, Lucy F.; Emery, Joshua P.; Moskovitz, Nicholas A.
2009-01-01
We report preliminary results from the Spitzer Infrared Spectrograph (IRS) observations of the V-type asteroid 956 Elisa. Elisa was observed as part of a campaign to measure the 5.2-38 micron spectra of small basaltic asteroids with the Spitzer IRS. Targets include members of the dynamical family of the unique large differentiated asteroid 4 Vesta ("Vesroids"), several outer-main-belt basaltic asteroids whose orbits exclude them from originating on 4 Vesta, and the basaltic near-Earth asteroid 4055 Magellan.
2017-04-03
145 the 7 surviving hamsters on day 28 (end of study), results of a nucleocapsid (N)- ELISA assay 146 indicate that 6 of the hamsters immunosuppressed...magnitude of the antibody response as measured by N- ELISA . 155 However, the results of this experiment do support the hypothesis that longer 156...supports the requirement for including Dex in a 177 combination treatment (Fig. 6D). Furthermore, results of an N- ELISA conducted with sera from 178
Practical colorimeter for direct measurement of microplates in enzyme immunoassay systems.
Clem, T R; Yolken, R H
1978-01-01
A colorimeter capable of measuring results of enzyme-linked immunosorbent assay (ELISA) reactions directly in the wells of a microtiter plate is described. This colorimeter proved to be as accurate as a conventional spectrophotometer in assessing ELISA reactions, but had the advantage of not requiring transfer of the specimen to a separate chamber. With this colorimeter, 96 specimens can be read in approximately 5 min. A practical colorimeter such as this can make the use of ELISA tests more feasible for many laboratories.
Henares, Terence G; Uenoyama, Yuta; Nogawa, Yuto; Ikegami, Ken; Citterio, Daniel; Suzuki, Koji; Funano, Shun-ichi; Sueyoshi, Kenji; Endo, Tatsuro; Hisamoto, Hideaki
2013-06-07
This paper presents a novel rhodamine diphosphate molecule that allows highly sensitive detection of proteins by employing sequential enzyme-linked immunosorbent assay and capillary isoelectric focusing (ELISA-cIEF). Seven-fold improvement in the immunoassay sensitivity and a 1-2 order of magnitude lower detection limit has been demonstrated by taking advantage of the combination of the enzyme-based signal amplification of ELISA and the concentration of enzyme reaction products by cIEF.
77 FR 26294 - Government-Owned Inventions; Availability for Licensing
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-03
... ELISA-like assay entirely to the molecular level, complex macroscopic or microfluidic washing and... for ELISA assays Modify or destroy target molecules, while detecting them Detect genetic diseases in...
Allen, Camryn D; Robbins, Michelle N; Eguchi, Tomoharu; Owens, David W; Meylan, Anne B; Meylan, Peter A; Kellar, Nicholas M; Schwenter, Jeffrey A; Nollens, Hendrik H; LeRoux, Robin A; Dutton, Peter H; Seminoff, Jeffrey A
2015-01-01
Determining sex ratios of endangered populations is important for wildlife management, particularly species subject to sex-specific threats or that exhibit temperature-dependent sex determination. Sea turtle sex is determined by incubation temperature and individuals lack external sex-based traits until sexual maturity. Previous research utilized serum/plasma testosterone radioimmunoassays (RIA) to determine sex in immature/juvenile sea turtles. However, there has been a growing application of enzyme-linked immunosorbent assay (ELISA) for wildlife endocrinology studies, but no study on sea turtles has compared the results of ELISA and RIA. This study provides the first sex ratio for a threatened East Pacific green sea turtle (Chelonia mydas) foraging aggregation, a critical step for future management of this species. Here, we validate a testosterone ELISA and compare results between RIA and ELISA of duplicate samples. The ELISA demonstrated excellent correspondence with the RIA for providing testosterone concentrations for sex determination. Neither assay proved reliable for predicting the sex of reproductively active females with increased testosterone production. We then applied ELISA to examine the sex ratio of 69 green turtles foraging in San Diego Bay, California. Of 45 immature turtles sampled, sex could not be determined for three turtles because testosterone concentrations fell between the ranges for either sex (females: 4.1-113.1 pg/mL, males: 198.4-2,613.0 pg/mL) and these turtles were not subsequently recaptured to enable sex determination; using a Bayesian model to predict probabilities of turtle sex we predicted all three 'unknowns' were female (> 0.86). Additionally, the model assigned all turtles with their correct sex (if determined at recapture) with 100% accuracy. Results indicated a female bias (2.83F:1M) among all turtles in the aggregation; when focusing only on putative immature turtles the sex ratio was 3.5F:1M. With appropriate validation, ELISA sexing could be applied to other sea turtle species, and serve as a crucial conservation tool.
Prevalence and distribution of paratuberculosis (Johne's disease) in cattle herds in Ireland
2009-01-01
A simple random survey was conducted in Ireland during 2005 to estimate the ELISA-prevalence of paratuberculosis, commonly called Johne's disease (JD), in the cattle population. Serum samples were collected from all 20,322 females/breeding bulls over 12 months-of-age in 639 herds. All samples were tested using a commercially available absorbed ELISA. The overall prevalence of infected herds, based on the presence of at least one ELISA-positive animal, was 21.4% (95% CI 18.4%-24.9%). Herd prevalence levels amongst dairy herds (mean 31.5%; 95% CI: 24.6%, 39.3%) was higher than among beef herds (mean 17.9%; 95% CI: 14.6%-21.8%). However, the animal level prevalence was similar. The true prevalence among all animals tested, was calculated to be 2.86% (95%CI: 2.76, 2.97) and for animals >= 2 yrs, it was 3.30% (95%CI: 3.17, 3.43). For animals in beef herds, true prevalence was 3.09% (95%CI: 2.93, 3.24), and for those in dairy herds, 2.74% (95%CI: 2.59, 2.90). The majority of herds had only one ELISA-positive infected animal. Only 6.4% (95% CI 4.7%-8.7%) of all herds had more than one ELISA-positive infected animal; 13.3% (CI 8.7%-19.7%) of dairy herds ranging from two to eight ELISA-positive infected animals; and, 3.9% beef herds (CI 2.4%-6.2%) ranging from two to five ELISA-positive infected animals. The true prevalence of herds infected and shedding Mycobacterium avium subspecies paratuberculosis is estimated to be 9.5% for all herd types; 20.6% for dairy herds; and 7.6% for beef herds. If ELISA positive animals <2-years-of-age are excluded, the true herd prevalene reduces to: 9.3% for all herd types; 19.6% for dairy herds; and 6.3% for beef herds based on a test specificity (Sp) of 99.8% and test sensitivity (Se) (i.e., ability to detect culture-positive, infected animals shedding at any level) of 27.8-28.9%. PMID:21851740
Tankaew, Pallop; Singh-La, Thawatchai; Titaram, Chatchote; Punyapornwittaya, Veerasak; Vongchan, Preeyanat; Sawada, Takuo; Sthitmatee, Nattawooti
2017-03-01
Pasteurella multocida causes haemorrhagic septicemia in livestock and wild animals, including elephants. The disease has been reported in Asian elephants in India and Sri Lanka, but to date there have been no reported cases in Thailand. ELISA or indirect hemagglutination assays (IHA) have been demonstrated to be able to detect the antibody against the disease in cattle, but no data are available for elephants. The present study reports a novel in-house indirect ELISA for antibody detection of haemorrhagic septicemia in Asian elephants, and evaluates the sensitivity and specificity of the method using a Bayesian approach. The characteristics of ELISA and IHA were analyzed using a one population Bayesian model assuming conditional dependence between these two diagnostic tests. The IHA was performed as recommended by the World Organization for Animal Health (OIE) manual for haemorrhagic septicemia. An in-house indirect ELISA was developed with a heat extract antigen of P. multocida strain M-1404 (serovar B:2) as a coating antigen and rabbit anti-immunoglobulin G conjugated with horseradish peroxidase (eIgG-HRP). The checkerboard titration method was done using elephant sera immunized with P. multocida bacterin and negative sera from colostrum-deprived elephant calves. The concentrations of heat extract antigen (160μg/ml), sample serum (1:100), and eIgG-HRP (1:1000) were optimal for the assay. The calculated cut-off value was 0.103. Of the elephant sera, 50.59% (43/85) were considered seropositive by ELISA. The sensitivity of the ELISA test was higher than that of the IHA test [median=86.5%, 95% posterior probability interval (PPI)=52.5-98.9%] while the specificity was lower (median=54.1%, PPI=43.6-64.7%). The median sensitivity and specificity of IHA were 80.5% (PPI=43.8-98.0%) and 78.4% (PPI=69.0-87.0%), respectively. These findings suggest that our in-house indirect ELISA can be used as a tool to detect the antibody against haemorrhagic septicemia in Asian elephants. Copyright © 2017 Elsevier B.V. All rights reserved.
Grandval, Philippe; De Caro, Alain; De Caro, Josiane; Sias, Barbara; Carrière, Frédéric; Verger, Robert; Laugier, René
2004-01-01
Human pancreatic lipases (HPL) include the classical HPL, and two related proteins known as pancreatic lipase-related proteins 1 and 2 (HPLRP1 and 2). The aim of this study was to develop an ELISA for specifically quantifying the classical-HPL level in sera of patients with and without pancreatic disorders. The specific activity of various human (including classical-HPL) and microbial lipases was measured using Lipa Vitros and potentiometric (pH-stat) assays. A double sandwich ELISA was also set up, using an anti-classical-HPL polyclonal antibody and a biotinylated monoclonal antibody (mAb 146-40) specific to the classical-HPL. Sera (n = 53) were collected from patients with and without pancreatic disorders. The lipase concentration was deduced from the measured lipolytic activity and compared with the corresponding classical-HPL concentration, measured with the ELISA. Both the purified HPLRP2 and 3 lipases of microbial origin were found to have a significant and unexpected lipolytic activity under the standard Lipa Vitros assay, whereas the ELISA test developed in the present study was found to be specific for the classical-HPL, due to the absence of cross-reactivity between mAb 146-40, HPLRP1 and HPLRP2. The efficiency of the ELISA was assessed in terms of its reproducibility and accuracy. The lower detection limit of classical-HPL was found to be 0.03 microg/l. A good correlation was found to exist between the lipase concentrations obtained in the ELISA, pH-stat and Lipa Vitros tests, in both the control and pathological groups. This is the first time a specific method of measuring classical-HPL in human serum has been proposed. Using this ELISA, we established with the 53 sera selected in the present study, that the Lipa Vitros assay as well as the pH-stat assay were mostly detecting classical pancreatic lipase. However, it is possible that other lipases such as HPLRP2 or lipases of microbial origin, present in some pathological sera, may well interfere with the Lipa Vitros assay. Copyright 2004 S. Karger AG, Basel and IAP.
ELISA versus PCR for diagnosis of chronic Chagas disease: systematic review and meta-analysis
2010-01-01
Background Most current guidelines recommend two serological tests to diagnose chronic Chagas disease. When serological tests are persistently inconclusive, some guidelines recommend molecular tests. The aim of this investigation was to review chronic Chagas disease diagnosis literature and to summarize results of ELISA and PCR performance. Methods A systematic review was conducted searching remote databases (MEDLINE, LILACS, EMBASE, SCOPUS and ISIWeb) and full texts bibliography for relevant abstracts. In addition, manufacturers of commercial tests were contacted. Original investigations were eligible if they estimated sensitivity and specificity, or reliability -or if their calculation was possible - of ELISA or PCR tests, for chronic Chagas disease. Results Heterogeneity was high within each test (ELISA and PCR) and threshold effect was detected only in a particular subgroup. Reference standard blinding partially explained heterogeneity in ELISA studies, and pooled sensitivity and specificity were 97.7% [96.7%-98.5%] and 96.3% [94.6%-97.6%] respectively. Commercial ELISA with recombinant antigens studied in phase three investigations partially explained heterogeneity, and pooled sensitivity and specificity were 99.3% [97.9%-99.9%] and 97.5% [88.5%-99.5%] respectively. ELISA's reliability was seldom studied but was considered acceptable. PCR heterogeneity was not explained, but a threshold effect was detected in three groups created by using guanidine and boiling the sample before DNA extraction. PCR sensitivity is likely to be between 50% and 90%, while its specificity is close to 100%. PCR reliability was never studied. Conclusions Both conventional and recombinant based ELISA give useful information, however there are commercial tests without technical reports and therefore were not included in this review. Physicians need to have access to technical reports to understand if these serological tests are similar to those included in this review and therefore correctly order and interpret test results. Currently, PCR should not be used in clinical practice for chronic Chagas disease diagnosis and there is no PCR test commercially available for this purpose. Tests limitations and directions for future research are discussed. PMID:21108793
Allen, Camryn D.; Robbins, Michelle N.; Eguchi, Tomoharu; Owens, David W.; Meylan, Anne B.; Meylan, Peter A.; Kellar, Nicholas M.; Schwenter, Jeffrey A.; Nollens, Hendrik H.; LeRoux, Robin A.; Dutton, Peter H.; Seminoff, Jeffrey A.
2015-01-01
Determining sex ratios of endangered populations is important for wildlife management, particularly species subject to sex-specific threats or that exhibit temperature-dependent sex determination. Sea turtle sex is determined by incubation temperature and individuals lack external sex-based traits until sexual maturity. Previous research utilized serum/plasma testosterone radioimmunoassays (RIA) to determine sex in immature/juvenile sea turtles. However, there has been a growing application of enzyme-linked immunosorbent assay (ELISA) for wildlife endocrinology studies, but no study on sea turtles has compared the results of ELISA and RIA. This study provides the first sex ratio for a threatened East Pacific green sea turtle (Chelonia mydas) foraging aggregation, a critical step for future management of this species. Here, we validate a testosterone ELISA and compare results between RIA and ELISA of duplicate samples. The ELISA demonstrated excellent correspondence with the RIA for providing testosterone concentrations for sex determination. Neither assay proved reliable for predicting the sex of reproductively active females with increased testosterone production. We then applied ELISA to examine the sex ratio of 69 green turtles foraging in San Diego Bay, California. Of 45 immature turtles sampled, sex could not be determined for three turtles because testosterone concentrations fell between the ranges for either sex (females: 4.1–113.1 pg/mL, males: 198.4–2,613.0 pg/mL) and these turtles were not subsequently recaptured to enable sex determination; using a Bayesian model to predict probabilities of turtle sex we predicted all three ‘unknowns’ were female (> 0.86). Additionally, the model assigned all turtles with their correct sex (if determined at recapture) with 100% accuracy. Results indicated a female bias (2.83F:1M) among all turtles in the aggregation; when focusing only on putative immature turtles the sex ratio was 3.5F:1M. With appropriate validation, ELISA sexing could be applied to other sea turtle species, and serve as a crucial conservation tool. PMID:26465620
Meyer, D; Fritsche, S; Luo, Y; Engemann, C; Blome, S; Beyerbach, M; Chang, C-Y; Qiu, H-J; Becher, P; Postel, A
2017-12-01
Emergency vaccination with live marker vaccines represents a promising control strategy for future classical swine fever (CSF) outbreaks, and the first live marker vaccine is available in Europe. Successful implementation is dependent on a reliable accompanying diagnostic assay that allows differentiation of infected from vaccinated animals (DIVA). As induction of a protective immune response relies on virus-neutralizing antibodies against E2 protein of CSF virus (CSFV), the most promising DIVA strategy is based on detection of E rns -specific antibodies in infected swine. The aim of this study was to develop and to evaluate a novel E rns -specific prototype ELISA (pigtype CSFV E rns Ab), which may be used for CSF diagnosis including application as an accompanying discriminatory test for CSFV marker vaccines. The concept of a double-antigen ELISA was shown to be a solid strategy to detect E rns -specific antibodies against CSFV isolates of different genotypes (sensitivity: 93.5%; specificity: 99.7%). Furthermore, detection of early seroconversion is advantageous compared with a frequently used CSFV E2 antibody ELISA. Clear differences in reactivity between sera taken from infected animals and animals vaccinated with various marker vaccines were observed. In combination with the marker vaccine CP7_E2alf, the novel ELISA represents a sensitivity of 90.2% and a specificity of 93.8%. However, cross-reactivity with antibodies against ruminant pestiviruses was observed. Interestingly, the majority of samples tested false-positive in other E rns -based antibody ELISAs were identified correctly by the novel prototype E rns ELISA and vice versa. In conclusion, the pigtype CSFV E rns Ab ELISA can contribute to an improvement in routine CSFV antibody screening, particularly for analysis of sera taken at an early time point after infection and is applicable as a DIVA assay. An additional E rns antibody assay is recommended for identification of false-positive results in a pig herd immunized with the licensed CP7_E2alf marker vaccine. © 2017 Blackwell Verlag GmbH.
Jiang, S; Cheng, H W; Hester, P Y; Hou, J-F
2013-08-01
Osteocalcin (OC) is a sensitive biochemical marker for evaluating bone turnover in mammals. The role of avian OC is less clear because of the need for a chicken assay. Our objectives were to develop an assay using indirect competitive ELISA for detecting chicken serum OC and use the assay to examine the effects of perches on bone remodeling in caged hens. Anti-chicken OC polyclonal antibody was produced by immunization of rabbits with a recombinant OC from Escherichia coli. Chicken OC extracted from bone was used as a coated protein, and purified chicken OC was used for calibration. The limit of detection of the developed OC ELISA was 0.13 ng/mL. The intra- and interassay CV were <7 and <12%, respectively. The sensitivity of the developed OC ELISA was compared with a commercial Rat-Mid OC ELISA in laying hens housed in conventional cages with or without perches. Serum samples were collected from 71-wk-old White Leghorn hens subjected to 4 treatments. Treatment 1 was control chickens that never had access to perches during their life cycle. Treatment 2 chickens had perches during the pullet phase (0 to 16.9 wk of age), whereas treatment 3 chickens had perches only during the egg-laying phase of the life cycle (17 to 71 wk of age). Treatment 4 chickens always had access to perches (0 to 71 wk of age). Correlation between the 2 assays was 0.62 (P < 0.0001). Levels of serum OC using the developed chicken ELISA were higher than that detected using the Rat-Mid ELISA (P < 0.0001). Results from the chicken ELISA assay showed that hens with perch access had higher concentrations of serum OC than hens without perches during egg laying (P = 0.04). Pullet access to perches did not affect serum OC levels in 71-wk-old hens (P = 0.15). In conclusion, a chicken OC ELISA has been validated that is sensitive and accurate with adequate discriminatory power for measuring bone remodeling in chickens.
Oplatowska-Stachowiak, Michalina; Sajic, Nermin; Haasnoot, Willem; Campbell, Katrina; Elliott, Christopher T.; Salden, Martin
2017-01-01
T-2 toxin/HT-2 toxin (T-2/HT-2) and ochratoxin A (OTA) are mycotoxins that can contaminate a variety of agricultural commodities. To protect consumers’ health, indicative limits for T-2/HT-2 and maximum limits for OTA have been set by the European Commission, requiring food business operators and controlling agencies to conduct routine checks for the presence of these harmful contaminants. Screening methods are increasingly used for monitoring purposes. Due to the demand for new and improved screening tools, two individual detection methods, T-2/HT-2 and OTA enzyme-linked immunosorbent assays (ELISAs), were developed in this study. The T-2/HT-2 ELISA was based on a T-2 monoclonal antibody with an IC50 (50% inhibitory concentration) of 0.28 ng/mL and 125% cross-reactivity with HT-2. As regards the OTA ELISA, a new sensitive monoclonal antibody specific to OTA with an IC50 of 0.13 ng/mL was produced. Both developed ELISA tests were then validated in agricultural commodities in accordance with the new performance criteria guidelines for the validation of screening methods for mycotoxins included in Commission Regulation (EU) No 519/2014. The T-2/HT-2 ELISA was demonstrated to be suitable for the detection of T-2/HT-2 in cereals and baby food at and above the screening target concentration (STC) of 12.5 μg/kg and 7.5 μg/kg, respectively. The OTA ELISA was shown to be applicable for the detection of OTA in cereals, coffee, cocoa and wine at and above the STC of 2 μg/kg, 2.5 μg/kg, 2.5 μg/kg and 0.4 ng/mL, respectively. The accuracy of both ELISAs was further confirmed by analysing proficiency test and reference samples. The developed methods can be used for sensitive and high-throughput screening for the presence of T-2/HT-2 and OTA in agricultural commodities. PMID:29189752
Oplatowska-Stachowiak, Michalina; Kleintjens, Tim; Sajic, Nermin; Haasnoot, Willem; Campbell, Katrina; Elliott, Christopher T; Salden, Martin
2017-11-30
T-2 toxin/HT-2 toxin (T-2/HT-2) and ochratoxin A (OTA) are mycotoxins that can contaminate a variety of agricultural commodities. To protect consumers' health, indicative limits for T-2/HT-2 and maximum limits for OTA have been set by the European Commission, requiring food business operators and controlling agencies to conduct routine checks for the presence of these harmful contaminants. Screening methods are increasingly used for monitoring purposes. Due to the demand for new and improved screening tools, two individual detection methods, T-2/HT-2 and OTA enzyme-linked immunosorbent assays (ELISAs), were developed in this study. The T-2/HT-2 ELISA was based on a T-2 monoclonal antibody with an IC 50 (50% inhibitory concentration) of 0.28 ng/mL and 125% cross-reactivity with HT-2. As regards the OTA ELISA, a new sensitive monoclonal antibody specific to OTA with an IC 50 of 0.13 ng/mL was produced. Both developed ELISA tests were then validated in agricultural commodities in accordance with the new performance criteria guidelines for the validation of screening methods for mycotoxins included in Commission Regulation (EU) No 519/2014. The T-2/HT-2 ELISA was demonstrated to be suitable for the detection of T-2/HT-2 in cereals and baby food at and above the screening target concentration (STC) of 12.5 μg/kg and 7.5 μg/kg, respectively. The OTA ELISA was shown to be applicable for the detection of OTA in cereals, coffee, cocoa and wine at and above the STC of 2 μg/kg, 2.5 μg/kg, 2.5 μg/kg and 0.4 ng/mL, respectively. The accuracy of both ELISAs was further confirmed by analysing proficiency test and reference samples. The developed methods can be used for sensitive and high-throughput screening for the presence of T-2/HT-2 and OTA in agricultural commodities.
Golden, Allison; Stevens, Eric J; Yokobe, Lindsay; Faulx, Dunia; Kalnoky, Michael; Peck, Roger; Valdez, Melissa; Steel, Cathy; Karabou, Potochoziou; Banla, Méba; Soboslay, Peter T; Adade, Kangi; Tekle, Afework H; Cama, Vitaliano A; Fischer, Peter U; Nutman, Thomas B; Unnasch, Thomas R; de los Santos, Tala; Domingo, Gonzalo J
2016-01-01
Serological assays for human IgG4 to the Onchocerca volvulus antigen Ov16 have been used to confirm elimination of onchocerciasis in much of the Americas and parts of Africa. A standardized source of positive control antibody (human anti-Ov16 IgG4) will ensure the quality of surveillance data using these tests. A recombinant human IgG4 antibody to Ov16 was identified by screening against a synthetic human Fab phage display library and converted into human IgG4. This antibody was developed into different positive control formulations for enzyme-linked immunosorbent assay (ELISA) and rapid diagnostic test (RDT) platforms. Variation in ELISA results and utility as a positive control of the antibody were assessed from multiple laboratories. Temperature and humidity conditions were collected across seven surveillance activities from 2011-2014 to inform stability requirements for RDTs and positive controls. The feasibility of the dried positive control for RDT was evaluated during onchocerciasis surveillance activity in Togo, in 2014. When the anti-Ov16 IgG4 antibody was used as a standard dilution in horseradish peroxidase (HRP) and alkaline phosphatase (AP) ELISAs, the detection limits were approximately 1ng/mL by HRP ELISA and 10ng/mL by AP ELISA. Positive control dilutions and spiked dried blood spots (DBS) produced similar ELISA results. Used as a simple plate normalization control, the positive control antibody may improve ELISA data comparison in the context of inter-laboratory variation. The aggregate temperature and humidity monitor data informed temperature parameters under which the dried positive control was tested and are applicable inputs for testing of diagnostics tools intended for sub-Saharan Africa. As a packaged positive control for Ov16 RDTs, stability of the antibody was demonstrated for over six months at relevant temperatures in the laboratory and for over 15 weeks under field conditions. The recombinant human anti-Ov16 IgG4 antibody-based positive control will benefit inter-laboratory validation of ELISA assays and serve as quality control (QC) reagents for Ov16 RDTs at different points of the supply chain from manufacturer to field use.
Emmerich, Petra; Mika, Angela; von Possel, Ronald; Rackow, Anne; Liu, Yang; Schmitz, Herbert; Sherifi, Kurtesh; Halili, Barie; Jakupi, Xhevat; Berisha, Lindita; Ahmeti, Salih
2018-01-01
As the most widespread tick-borne arbovirus causing infections in numerous countries in Asia, Africa and Europe, Crimean-Congo Hemorrhagic Fever Virus (CCHFV, family Nairoviridae) was included in the WHO priority list of emerging pathogens needing urgent Research & Development attention. To ensure preparedness for potential future outbreak scenarios, reliable diagnostic tools for identification of acute cases as well as for performance of seroprevalence studies are necessary. Here, the CCHFV ortholog of the major bunyavirus antigen, the nucleoprotein (NP), was recombinantly expressed in E.coli, purified and directly labeled with horseradish peroxidase (HRP). Employing this antigen, two serological tests, a μ-capture ELISA for the detection of CCHFV-specific IgM antibodies (BLACKBOX CCHFV IgM) and an IgG immune complex (IC) ELISA for the detection of CCHFV-specific IgG antibodies (BLACKBOX CCHFV IgG), were developed. Test performance was evaluated and compared with both in-house gold standard testing by IgM/IgG indirect immunofluorescence (IIF) and commercially available ELISA tests (VectoCrimean-CHF-IgM/IgG, Vector-Best, Russia) using a serum panel comprising paired samples collected in Kosovo during the years 2013–2016 from 15 patients with an acute, RT-PCR-confirmed CCHFV infection, and 12 follow-up sera of the same patients collected approximately one year after having overcome the infection. Reliably detecting IgM antibodies in all acute phase sera collected later than day 4 after onset of symptoms, both IgM ELISAs displayed excellent diagnostic and analytical sensitivity (100%, 95% confidence interval (CI): 85.2%–100.0%). While both IgG ELISAs readily detected the high IgG titers present in convalescent patients approximately one year after having overcome the infection (sensitivity 100%, 95% CI: 73.5%–100.0%), the newly developed BLACKBOX CCHFV IgG ELISA was superior to the commercial IgG ELISA in detecting the rising IgG titers during the acute phase of the disease. While all samples collected between day 11 and 19 after onset of symptoms tested positive in both the in-house gold standard IIFT and the BLACKBOX CCHFV IgG ELISA (sensitivity 100%, 95% CI: 71.5%–100.0%), only 27% (95% CI: 6.0%–61.0%) of those samples were tested positive in the commercial IgG ELISA. No false positive signals were observed in either IgM/IgG ELISA when analyzing a priori CCHFV IgM/IgG negative serum samples from healthy blood donors, malaria patients and flavivirus infected patients as well as CCHFV IgM/IgG IIFT negative serum samples from healthy Kosovar blood donors (for BLACKBOX CCHFV IgM/IgG: n = 218, 100% specificity, 95% CI: 98.3%–100.0%, for VectoCrimean-CHF-IgM/IgG: n = 113, 100% specificity, 95% CI: 96.8%–100.0%). PMID:29579040
Grantee Spotlight: Elisa Rodriguez, Ph.D., M.S.
Dr. Elisa M. Rodriguez tests the feasibility of community-based participatory research approaches to engaging Hispanics, African Americans, and the medically underserved in the Buffalo, NY area in biospecimen donation for cancer research.
... http://www.beckmancoulter.com . Began, T. (2002 October). Elisa D-Dimer: How Accurate For PE Diagnosis? PulmonaryReviews. ... at http://www.pulmonaryreviews.com/oct02/pr_oct02_ELISA.html through http://www.pulmonaryreviews.com . Cortese Hassett, ...
Improvement of an enzyme immunosorbent assay for detecting antibodies against Dioctophyma renale.
Pedrassani, Daniela; do Nascimento, Adjair Antonio; André, Marcos Rogério; Machado, Rosangela Zacarias
2015-09-15
An available enzyme-linked immunosorbent assay (ELISA) was studied for the detection of anti-Dioctophyma renale antibodies in the sera of dogs using, detection of parasite eggs in urine sediment as a reference test. ELISA uses a soluble antigenic preparation of esophagus of D. renale and the optimal dilutions of the antigen, serum and conjugate were determined by means of checker board titration, using positive (n=13) and negative (n=27) reference serum. The specificity and sensitivity of the ELISA were 93.8% and 92.3% respectively and the kappa index was good (0.76). These results suggest that ELISA described may prove to be an effective serological test for detecting dogs infected and exposed to this parasite mainly dogs that are not eliminating parasite eggs through their urine. Copyright © 2015 Elsevier B.V. All rights reserved.
van Loon, A. M.; van der Logt, J. T.; Heessen, F. W.; Heeren, M. C.; Zoll, J.
1992-01-01
Antibody-capture enzyme-linked immunosorbent assays (AC-ELISA) which use enzyme-labelled antigen were developed for detection of varicella-zoster virus-(VZV) specific IgM, IgA and IgG antibody in patients with varicella or herpes zoster and in sera from healthy individuals. All 18 patients with varicella developed a VZV-IgM and a VZV-IgG response, 17 also a VZV-IgA response. In contrast, all 19 patients with herpes zoster were shown to be positive for VZV-IgA whereas only 13 of these reacted positively for VZV-IgM. A VZV-IgM response was detected in only two sera from 100 healthy individuals and an IgA response in only one. The presence of virus-specific IgA and IgG in the cerebrospinal fluid as determined by AC-ELISA was a useful indicator of VZV infection of the central nervous system. By AC-ELISA, VZV-IgG was detected predominantly in sera from patients with acute or recent VZV infection. Only 14 sera from 100 healthy individuals were positive for VZV-IgG by AC-ELISA, whereas all were positive by an indirect ELISA. These results indicate that AC-ELISA's may be useful assays for determination for acute or recurrent VZV infection, but are not suitable for determination of past infection with this virus. PMID:1312479
Ackermann-Gäumann, Rahel; Tritten, Marie-Lise; Hassan, Mona; Lienhard, Reto
2018-05-01
Tick-borne encephalitis (TBE) is endemic in many parts of Europe and Asia. The diagnosis of this disease is essentially based on the demonstration of specific antibodies. For reasons of simplicity, automatization and quick availability of test results, enzyme-linked immunosorbent assays (ELISAs) are the method of choice for serological diagnosis of TBE. Here, we evaluated three commercially available anti-TBEV IgG and IgM ELISAs using 251 serum samples: the SERION ELISA classic FSME Virus/TBE Virus IgG and IgM kit (Virion\\Serion), the RIDASCREEN ® FSME/TBE IgG and IgM kit (R-Biopharm), and the anti-FSME/TBE virus ELISA "Vienna" IgG/anti-FSME/TBE virus ELISA IgM kit (Euroimmun). In total, discrepant test results for IgG and/or IgM were observed for 37/251 (14.7 %) of tested samples; differences were statistically significant. Reference values defined by serum neutralization test (SNT, n = 25) or results provided by EQA organizers (n = 2) were established for a subset of samples. In relation to these values, false-positive results were observed mainly for Euroimmun Vienna IgG and RIDASCREEN IgG, whereas false-negative results were primarily observed for Virion\\Serion IgG and RIDASCREEN IgM kits. In routine diagnostics, specificity problems are of major relevance and may be addressed by analyzing the respective samples using SNT. Copyright © 2018 Elsevier GmbH. All rights reserved.
He, Fang; Kiener, Tanja K; Lim, Xiao Fang; Tan, Yunrui; Raj, Kattur Venkatachalam Ashok; Tang, Manli; Chow, Vincent T K; Chen, Qingfeng; Kwang, Jimmy
2013-01-01
Human Enterovirus 71 (EV71) is a common cause of hand, foot and mouth disease (HFMD) in young children. It is often associated with severe neurological diseases and mortalities in recent outbreaks across the Asia Pacific region. Currently, there is no efficient universal antibody test available to detect EV71 infections. In the present study, an epitope-blocking ELISA was developed to detect specific antibodies to human EV71 viruses in human or animal sera. The assay relies on a novel monoclonal antibody (Mab 1C6) that specifically binds to capsid proteins in whole EV71 viruses without any cross reaction to any EV71 capsid protein expressed alone. The sensitivity and specificity of the epitope-blocking ELISA for EV71 was evaluated and compared to microneutralization using immunized animal sera to multiple virus genotypes of EV71 and coxsackieviruses. Further, 200 serum sample from human individuals who were potentially infected with EV71 viruses were tested in both the blocking ELISA and microneutralization. Results indicated that antibodies to EV71 were readily detected in immunized animals or human sera by the epitope blocking ELISA whereas specimens with antibodies to other enteroviruses yielded negative results. This assay is not only simpler to perform but also shows higher sensitivity and specificity as compared to microneutralization. The epitope-blocking ELISA based on a unique Mab 1C6 provided highly sensitive and 100% specific detection of antibodies to human EV71 viruses in human sera.
Butterworth, Alice S; Robertson, Alan J; Ho, Mei-Fong; Gatton, Michelle L; McCarthy, James S; Trenholme, Katharine R
2011-04-18
Obtaining single parasite clones is required for many techniques in malaria research. Cloning by limiting dilution using microscopy-based assessment for parasite growth is an arduous and labor-intensive process. An alternative method for the detection of parasite growth in limiting dilution assays is using a commercial ELISA histidine-rich protein II (HRP2) detection kit. Detection of parasite growth was undertaken using HRP2 ELISA and compared to thick film microscopy. An HRP2 protein standard was used to determine the detection threshold of the HRP2 ELISA assay, and a HRP2 release model was used to extrapolate the amount of parasite growth required for a positive result. The HRP2 ELISA was more sensitive than microscopy for detecting parasite growth. The minimum level of HRP2 protein detection of the ELISA was 0.11 ng/ml. Modeling of HRP2 release determined that 2,116 parasites are required to complete a full erythrocytic cycle to produce sufficient HRP2 to be detected by the ELISA. Under standard culture conditions this number of parasites is likely to be reached between 8 to 14 days of culture. This method provides an accurate and simple way for the detection of parasite growth in limiting dilution assays, reducing time and resources required in traditional methods. Furthermore the method uses spent culture media instead of the parasite-infected red blood cells, enabling culture to continue. © 2011 Butterworth et al; licensee BioMed Central Ltd.
Rallabhandi, Prasad; Sharma, Girdhari M; Pereira, Marion; Williams, Kristina M
2015-02-18
Gluten proteins in wheat, rye and barley cause celiac disease, an autoimmune disorder of the small intestine, which affects approximately 1% of the world population. Gluten is comprised of prolamin and glutelin. Since avoidance of dietary gluten is the only option for celiac patients, a sensitive gluten detection and quantitation method is warranted. Most regulatory agencies have set a threshold of 20 ppm gluten in foods labeled gluten-free, based on the currently available ELISA methods. However, these methods may exhibit differences in gluten quantitation from different gluten-containing grains. In this study, prolamin and glutelin fractions were isolated from wheat, rye, barley, oats and corn. Intact and pepsin-trypsin (PT)-digested prolamin and glutelin fractions were used to assess their immunoreactivity and gluten recovery by three sandwich and two competitive ELISA kits. The Western blots revealed varied affinity of ELISA antibodies to gluten-containing grain proteins and no reactivity to oat and corn proteins. ELISA results showed considerable variation in gluten recoveries from both intact and PT-digested gluten fractions among different kits. Prolamin fractions showed higher gluten recovery compared to their respective glutelin fractions. Among prolamins, barley exhibited higher recovery compared to wheat and rye with most of the ELISA kits used. Hydrolysis resulted in reduced gluten recovery of most gluten fractions. These results suggest that the suitability of ELISA for accurate gluten quantitation is dependent upon various factors, such as grain source, antibody specificity, gluten proteins and the level of their hydrolysis in foods.
Roesler, Uwe; Szabo, Istvan; Matthies, Claudia; Albrecht, Kerstin; Leffler, Martin; Scherer, Kathrin; Nöckler, Karsten; Lehmann, Jörg; Methner, Ulrich; Hensel, Andreas; Truyen, Uwe
2011-01-01
The objective of this study was the comparative evaluation of four indirect Salmonella ELISA tests at study time approved in Germany to detect Salmonella infection in pigs.Three tests are based on a LPS-antigen mix and directed against specific IgG antibodies. The fourth test is based on a purified S. Typhimurium whole-cell lysate antigen and discriminates between Salmonella-specific IgM-, IgA-, and IgG- antibodies. In a longitudinal study, two groups of six weeks old hybrid piglets were orally infected with a porcine S. Infantis or S. Derby strain. Clinical and bacteriological parameters were monitored weekly during an observation period of 130 days after infection and serum samples were investigated in parallel with the respective ELISAs. Apparently, the LPS-based ELISA systems used in this study failed to recognize S. Infantis-infected pigs although those animals shed the pathogen in high amounts throughout the study until day 81 post infection (p. i.). In contrast, the isotype-specific Salmonella Typhimurium whole-cell-lysate based ELISA was capable of detecting Salmonella-infected pigs from day ten p. i. at all tested serotypes and revealed the highest sensitivity in detection of S. Infantis-infected pigs. Furthermore, it became apparent that the often used surveillance cut-off value of 40 OD% is not appropriate for intra-vitam detection of S. Infantis- and S. Derby-infected pigs. In contrast, the cut-off values of the ELISAs given by the suppliers result in considerable higher detection rates.
Yang, Mei; Wang, Zhuoya; Hao, Wei; Wang, Yanfang; Huang, Li; Cai, Jianpiao; Jiang, Lingxiao; Che, Xiaoyan; Zhong, Xiaozhu; Yu, Nan
2014-05-01
To establish two double-antigen sandwich ELISA systems to detect anti-Afmp1cr and Afmp2cr antibodies of Aspergillus fumigatus. Recombinant Afmp1cr and Afmp2cr proteins of A.fumigatus expressed in Pichia pastoris were obtained. Double-antigen sandwich ELISA systems for detecting specific anti-Afmp1cr and anti-Afmp2cr antibodies were developed after chessboard titrating to determine the appropriate concentrations of the recombinant proteins and HRP-labeled proteins. The sensitivity of the assay was evaluated using serum samples of rabbits immunized with Afmp1cr and Afmp2cr. The specificity of the assay was evaluated by detecting serum samples from healthy donors and patients with other pathogenic fungal and baterial infections. The performance of the two ELISA kits was furthered evaluated using serum samples from patients with suspected Aspergillus infection. The established ELISA kits were capable of detecting anti-Afmp1cr and anti-Afmp2cr antibodies in immunized rabbit serum at the maximum dilutions of 800 and 3200, respectively. No cross-reactivity was observed in detecting serum from patients with other pathogenic fungal or bactetial infections. Both of the two kits yielded positive results in sera from two established Aspergillus-infected cases and a suspected case. Two antibody-capture ELISA kits were developed for the laboratory diagnosis of A.fumigatus infection and can be potentially useful in the clinical diagnosis of Aspergillosis infections.
Dangoudoubiyam, Sriveny; Vemulapalli, Ramesh; Ndao, Momar; Kazacos, Kevin R.
2011-01-01
Baylisascaris larva migrans is an important zoonotic disease caused by Baylisascaris procyonis, the raccoon roundworm, and is being increasingly considered in the differential diagnosis of eosinophilic meningoencephalitis in children and young adults. Although a B. procyonis excretory-secretory (BPES) antigen-based enzyme-linked immunosorbent assay (ELISA) and a Western blot assay are useful in the immunodiagnosis of this infection, cross-reactivity remains a major problem. Recently, a recombinant B. procyonis antigen, BpRAG1, was reported for use in the development of improved serological assays for the diagnosis of Baylisascaris larva migrans. In this study, we tested a total of 384 human patient serum samples in a BpRAG1 ELISA, including samples from 20 patients with clinical Baylisascaris larva migrans, 137 patients with other parasitic infections (8 helminth and 4 protozoan), and 227 individuals with unknown/suspected parasitic infections. A sensitivity of 85% and a specificity of 86.9% were observed with the BpRAG1 ELISA, compared to only 39.4% specificity with the BPES ELISA. In addition, the BpRAG1 ELISA had a low degree of cross-reactivity with antibodies to Toxocara infection (25%), while the BPES antigen showed 90.6% cross-reactivity. Based on these results, the BpRAG1 antigen has a high degree of sensitivity and specificity and should be very useful and reliable in the diagnosis and seroepidemiology of Baylisascaris larva migrans by ELISA. PMID:21832102
NASA Astrophysics Data System (ADS)
Lin, Margaret; Krawitz, Denise; Callahan, Matthew D.; Deperalta, Galahad; Wecksler, Aaron T.
2018-05-01
We describe epitope mapping data using multiple covalent labeling footprinting-mass spectrometry (MS) techniques coupled with negative stain transmission electron microscopy (TEM) data to analyze the antibody-antigen interactions in a sandwich enzyme-linked immunosorbant assay (ELISA). Our hydroxyl radical footprinting-MS data using fast photochemical oxidation of proteins (FPOP) indicates suppression of labeling across the antigen upon binding either of the monoclonal antibodies (mAbs) utilized in the ELISA. Combining these data with Western blot analysis enabled the identification of the putative epitopes that appeared to span regions containing N-linked glycans. An additional structural mapping technique, carboxyl group footprinting-mass spectrometry using glycine ethyl ester (GEE) labeling, was used to confirm the epitopes. Deglycosylation of the antigen resulted in loss of potency in the ELISA, supporting the FPOP and GEE labeling data by indicating N-linked glycans are necessary for antigen binding. Finally, mapping of the epitopes onto the antigen crystal structure revealed an approximate 90° relative spatial orientation, optimal for a noncompetitive binding ELISA. TEM data shows both linear and diamond antibody-antigen complexes with a similar binding orientation as predicted from the two footprinting-MS techniques. This study is the first of its kind to utilize multiple bottom-up footprinting-MS techniques and TEM visualization to characterize the monoclonal antibody-antigen binding interactions of critical reagents used in a quality control (QC) lot-release ELISA. [Figure not available: see fulltext.
Guo, Lingling; Song, Shanshan; Liu, Liqiang; Peng, Juan; Kuang, Hua; Xu, Chuanlai
2015-09-01
Rapid and sensitive indirect competitive enzyme-linked immunosorbent assays (ic-ELISA) and gold nanoparticle immunochromatographic strip tests were developed to detect thiamphenicol (TAP), florfenicol (FF) and chloramphenicol (CAP) in milk and honey samples. The generic monoclonal antibody for TAP, FF and CAP was prepared based on a hapten [D-threo-1-(4-aminophenyl)-2- dichloroacetylamino-1,3-propanediol], and the haptenwas linked to a carrier protein using the diazotization method. After the optimization of several parameters (coating, pH, sodium chloride content and methanol content), the ic-ELISA was established. The quantitative working range for TAP was 0.11-1.36 ng/mL, with an IC50 of 0.39 ng/mL. The optimized ELISA showed cross-reactivity to CAP (300%) and FF (15.6%), with IC50 values of 0.13 and 2.5 ng/mL, respectively. The analytical recovery of TAP, FF and CAP in milk and honey samples in the ic-ELISA ranged from 81.2 to 112.9%. Based on this monoclonal antibody, a rapid and sensitive immunochromatographic test strip was also developed. This strip had a detection limit of 1 ng/mL for TAP, FF and CAP in milk and honey samples. Moreover, the test was completed within 10 min. Our results showed that the proposed ic-ELISA and immunochromatographic test strip method are highly useful screening tools for TAP, FF and CAP detection in milk and honey samples. Copyright © 2015 John Wiley & Sons, Ltd.
ELISA for detection of variant rabbit haemorrhagic disease virus RHDV2 antigen in liver extracts.
Dalton, K P; Podadera, A; Granda, V; Nicieza, I; Del Llano, D; González, R; de Los Toyos, J R; García Ocaña, M; Vázquez, F; Martín Alonso, J M; Prieto, J M; Parra, F; Casais, R
2018-01-01
The emergence and rapid spread of variant of the rabbit hemorrhagic disease virus (RHDV2) require new diagnostic tools to ensure that efficient control measures are adopted. In the present study, a specific sandwich enzyme-linked immunosorbent assay (ELISA) for detection of RHDV2 antigens in rabbit liver homogenates, based on the use of an RHDV2-specific monoclonal antibody (Mab) 2D9 for antigen capture and an anti-RHDV2 goat polyclonal antibody (Pab), was developed. This ELISA was able to successfully detect RHDV2 and RHDV2 recombinant virions with high sensitivity (100%) and specificity (97.22%). No cross-reactions were detected with RHDV G1 viruses while low cross-reactivity was detected with one of the RHDVa samples analyzed. The ELISA afforded good repeatability and had high analytical sensitivity as it was able to detect a dilution 1:163,640 (6.10ng/mL) of purified RHDV-N11 VLPs, which contained approximately 3.4×10 8 molecules/mL particles. The reliable discrimination between closely related viruses is crucial to understand the epidemiology and the interaction of co-existing pathogens. In the work described here we design and validate an ELISA for laboratory based, specific, sensitive and reliable detection of RHDVb/RHDV2. This ELISA is a valuable, specific virological tool for monitoring virus circulation, which will permit a better control of this disease. Copyright © 2017 Elsevier B.V. All rights reserved.
Wang, ShuQi; Zhao, Xiaohu; Khimji, Imran; Akbas, Ragip; Qiu, Weiliang; Edwards, Dale; Cramer, Daniel W.; Ye, Bin; Demirci, Utkan
2013-01-01
Ovarian cancer is asymptomatic at early stages and most patients present with advanced levels of disease. Lack of cost-effective methods that can achieve frequent, simple and non-invasive testing hinders early detection and causes high mortality in ovarian cancer patients. Here, we report a simple and inexpensive microchip ELISA-based detection module that employs a portable detection system, i.e., a cell phone/charge-coupled device (CCD) to quantify an ovarian cancer biomarker, HE4, in urine. Integration of a mobile application with a cell phone enabled immediate processing of microchip ELISA results, which eliminated the need for a bulky, expensive spectrophotometer. The HE4 level detected by a cell phone or a lensless CCD system was significantly elevated in urine samples from cancer patients (n = 19) than normal healthy controls (n = 20) (p < 0.001). Receiver operating characteristic (ROC) analyses showed that the microchip ELISA coupled with a cell phone running an automated analysis application had a sensitivity of 89.5% at a specificity of 90%. Under the same specificity, the microchip ELISA coupled with a CCD had a sensitivity of 84.2%. In conclusion, integration of microchip ELISA with cell phone/CCD-based colorimetric measurement technology can be used to detect HE4 biomarker at the point-of-care (POC), paving the way to create bedside technologies for diagnostics and treatment monitoring. PMID:21881677
Machado, A A; Martinez, R; Haikal, A A; Rodrigues da Silva, M C
2001-01-01
In occupational accidents involving health professionals handling potentially contaminated material, the decision to start or to continue prophylactic medication against infection by Human Immunodeficiency Virus (HIV) has been based on the ELISA test applied to a blood sample from the source patient. In order to rationalize the prophylactic use of antiretroviral agents, a rapid serologic diagnostic test of HIV infection was tested by the enzymatic immunoabsorption method (SUDS HIV 1+2, MUREX) and compared to conventional ELISA (Abbott HIV-1/ HIV-2 3rd Generation plus EIA). A total of 592 cases of occupational accidents were recorded at the University Hospital of Ribeirão Preto from July 1998 to April 1999. Of these, 109 were simultaneously evaluated by the rapid test and by ELISA HIV. The rapid test was positive in three cases and was confirmed by ELISA and in one the result was inconclusive and later found to be negative by ELISA. In the 106 accidents in which the rapid test was negative no prophylactic medication was instituted, with an estimated reduction in costs of US$ 2,889.35. In addition to this advantage, the good correlation of the rapid test with ELISA, the shorter duration of stress and the absence of exposure of the health worker to the adverse effects of antiretroviral agents suggest the adoption of this test in Programs of Attention to Accidents with Potentially Contaminated Material.
Influenza A virus H5-specific antibodies in mute swans (Cygnus olor) in the USA.
Kistler, Whitney M; Stallknecht, David E; Lebarbenchon, Camille; Pedersen, Kerri; Marks, David R; Mickley, Randy; DeLiberto, Thomas J; Yabsley, Michael J
2015-04-01
The use of serologic assays for influenza A virus (IAV) surveillance in wild birds has increased because of the availability of commercial enzyme-linked immunosorbent assays (ELISAs). Recently, an H5-specific blocking ELISA (bELISA) was shown to reliably detect H5-specific antibodies to low- and high-pathogenic H5 viruses in experimentally infected waterfowl. Mute Swans (Cygnus olor) were frequently associated with highly pathogenic H5N1 outbreaks in Europe and may have a similar role if highly pathogenic H5N1 is introduced into North America. We measured the prevalence of antibodies to the nucleoprotein and H5 protein in Mute Swans using three serologic assays. We collected 340 serum samples from Mute Swans in Michigan, New Jersey, New York, and Rhode Island, US. We detected antibodies to the IAV nucleoprotein in 66.2% (225/340) of the samples. We detected H5-specific antibodies in 62.9% (214/340) and 18.8% (64/340) using a modified H5 bELISA protocol and hemagglutination inhibition (HI) assay, respectively. The modified H5 bELISA protocol detected significantly more positive samples than did the manufacturer's protocol. We also tested 46 samples using virus neutralization. Neutralization results had high agreement with the modified H5 bELISA protocol and detected a higher prevalence than did the HI assay. These results indicate that North American Mute Swans have high nucleoprotein and H5 antibody prevalences.
Cao, Biyun; Yang, Hong; Song, Juan; Chang, Huafang; Li, Shuqun; Deng, Anping
2013-11-15
The adulteration of food products with melamine has led to an urgent requirement for sensitive, specific, rapid and reliable quantitative/screening methods. To enhance the sensitivity and specificity of the enzyme-linked immunosorbent assay (ELISA) for the detection of melamine in milk, milk powder and feed samples, rational hapten modification and heterogeneous antibody/coating antigen combinations were adopted. Three melamine derivatives with different length of carboxylic spacer at the end were synthesized and linked to carrier proteins for the production of immunogens and coating antigens. Monoclonal antibody against melamine was produced by hybridoma technology. Under optimal experimental conditions, the standard curves of the ELISAs for melamine were constructed in range of 0.1-100 ng mL(-1). The sensitivity was 10-300 times enhanced compared to those in the published literatures. The cross-reactivity values of the ELISAs also demonstrated the assays exhibited high specificity. Five samples were spiked with melamine at different concentrations and detected by the ELISA. The recovery rates of 72.8-123.0% and intra-assay coefficients of variation of 0.8-18.9% (n=3) were obtained. The ELISA for milk sample was confirmed by high-performance liquid chromatography with a high correlation coefficient of 0.9902 (n=6). The proposed ELISA was proven to be a feasible quantitative/screening method for melamine analysis. Copyright © 2013 Elsevier B.V. All rights reserved.
Garcia, Hector H; Castillo, Yesenia; Gonzales, Isidro; Bustos, Javier A; Saavedra, Herbert; Jacob, Louis; Del Brutto, Oscar H; Wilkins, Patricia P; Gonzalez, Armando E; Gilman, Robert H
2018-01-01
To evaluate the diagnostic performance of two commercially available ELISA kits, Novalisa ® and Ridascreen ® , for the detection of antibodies to Taenia solium, compared to serological diagnosis of neurocysticercosis (NCC) by LLGP-EITB (electro-immunotransfer blot assay using lentil-lectin purified glycoprotein antigens). Archive serum samples from patients with viable NCC (n = 45) or resolved, calcified NCC (n = 45), as well as sera from patients with other cestode parasites (hymenolepiasis, n = 45 and cystic hydatid disease, n = 45), were evaluated for cysticercosis antibody detection using two ELISA kits, Novalisa ® and Ridascreen ® . All NCC samples had previously tested positive, and all samples from heterologous infections were negative on LLGP-EITB for cysticercosis. Positive rates were calculated by kit and sample group and compared between the two kits. Compared to LLGP-EITB, the sensitivity of both ELISA assays to detect specific antibodies in patients with viable NCC was low (44.4% and 22.2%), and for calcified NCC, it was only 6.7% and 4.5%. Sera from patients with cystic hydatid disease were highly cross-reactive in both ELISA assays (38/45, 84.4%; and 25/45, 55.6%). Sera from patients with hymenolepiasis cross-reacted in five cases in one of the assays (11.1%) and in only one sample with the second assay (2.2%). The performance of Novalisa ® and Ridascreen ® was poor. Antibody ELISA detection cannot be recommended for the diagnosis of neurocysticercosis. © 2017 John Wiley & Sons Ltd.
Desomorphine Screening Using Commercial Enzyme-Linked Immunosorbent Assays.
Winborn, Jessica; Kerrigan, Sarah
2017-06-01
Desomorphine ("Krokodil") is a semi-synthetic opioid that has drawn attention as a recreational drug, particularly in Russia, neighboring former Soviet Republics, Eastern and Central Europe. It has no accepted medicinal uses and is currently a schedule I drug in the United States. In clandestine environments, desomorphine is synthesized from codeine using red phosphorous, hydroiodic acid and gasoline. Residual starting materials in illicit preparations have been associated with severe dermatological effects and extensive tissue necrosis. Desomorphine is not well studied, and there are limited reports concerning its pharmacology or detection in biological matrices. Immunoassays are widely relied upon for both antemortem and postmortem toxicology screening. Although desomorphine is an opioid of the phenanthrene-type, its ability to bind to conventional opioid antibodies has not been described. In this report we describe the cross-reactivity of desomorphine using six commercially available enzyme-linked immunosorbent assays (Immunalysis Opiates Direct ELISA, Immunalysis Oxycodone/Oxymorphone Direct ELISA, Randox Opiate ELISA, OraSure Technologies OTI Opiate Micro-plate EIA, Neogen Opiate Group ELISA and Neogen Oxycodone/Oxymorphone ELISA). Cross-reactivites were highly variable between assays, ranging from 77 to <2.5%. In general, assays directed towards morphine produced greater cross-reactivity with desomorphine than those directed towards oxycodone. The Immunalysis Opiates Direct ELISA produced the greatest cross-reactivity, although several of the assays evaluated produced cross-reactivity of a sufficient magnitude to be effective for desomorphine screening. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Vázquez-Avila, Isidro; Vera-Peralta, Jorge Manuel; Alvarez-Nemegyei, José; Rodríguez-Carvajal, Otilia
2007-01-01
In order to decrease the burden of suffering and the costs derived from confirmatory molecular assays, a better strategy is badly needed to decrease the rate of false positive results of the enzyme-linked immunoassay (ELISA) for detection of hepatitis C virus (HCV) antibodies (Anti). To establish the best cutoff of the S/CO rate in subjects with a positive result of a microparticule, third generation ELISA assay for Anti-HCV, for predicting viremia as detected by polymerase chain reaction (PCR) assay. Using the result of the PCR assay as "gold standard", a ROC curve was build with the results of the S/CO rate values in subjects with a positive result for ELISA HCV assay. Fifty two subjects (30 male, 22 female, 40 +/- 12.5 years old) were included. Thirty four (65.3%) had a positive RNA HCV PCR assay. The area under the curve was 0.99 (95% CI: 0.98-1.0). The optimal cutoff for the S/CO rate was established in 29: sensitivity: 97%; specificity: 100%: PPV: 100%; NPV: 94%. Setting the cutoff of the S/CO in 29 results in a high predictive value for viremia as detected by PCR in subjects with a positive ELISA HVC assay. This knowledge may result in a better decision taking for the clinical follow up of those subjects with a positive result in the ELISA screening assay for HCV infection.
Lin, Margaret; Krawitz, Denise; Callahan, Matthew D; Deperalta, Galahad; Wecksler, Aaron T
2018-05-01
We describe epitope mapping data using multiple covalent labeling footprinting-mass spectrometry (MS) techniques coupled with negative stain transmission electron microscopy (TEM) data to analyze the antibody-antigen interactions in a sandwich enzyme-linked immunosorbant assay (ELISA). Our hydroxyl radical footprinting-MS data using fast photochemical oxidation of proteins (FPOP) indicates suppression of labeling across the antigen upon binding either of the monoclonal antibodies (mAbs) utilized in the ELISA. Combining these data with Western blot analysis enabled the identification of the putative epitopes that appeared to span regions containing N-linked glycans. An additional structural mapping technique, carboxyl group footprinting-mass spectrometry using glycine ethyl ester (GEE) labeling, was used to confirm the epitopes. Deglycosylation of the antigen resulted in loss of potency in the ELISA, supporting the FPOP and GEE labeling data by indicating N-linked glycans are necessary for antigen binding. Finally, mapping of the epitopes onto the antigen crystal structure revealed an approximate 90° relative spatial orientation, optimal for a noncompetitive binding ELISA. TEM data shows both linear and diamond antibody-antigen complexes with a similar binding orientation as predicted from the two footprinting-MS techniques. This study is the first of its kind to utilize multiple bottom-up footprinting-MS techniques and TEM visualization to characterize the monoclonal antibody-antigen binding interactions of critical reagents used in a quality control (QC) lot-release ELISA. Graphical Abstract ᅟ.
Wenzel, Katrin; Schulze-Rothe, Sarah; Müller, Johannes; Wallukat, Gerd; Haberland, Annekathrin
2018-01-01
Cell-based analytics for the detection of the beta1-adrenoceptor autoantibody (beta1-AAB) are functional, yet difficult to handle, and should be replaced by easily applicable, routine lab methods. Endeavors to develop solid-phase-based assays such as ELISA to exploit epitope moieties for trapping autoantibodies are ongoing. These solid-phase-based assays, however, are often unreliable when used with human patient material, in contrast to animal derived autoantibodies. We therefore tested an immunogen peptide-based ELISA for the detection of beta1-AAB, and compared commercially available goat antibodies against the 2nd extracellular loop of human beta1-adrenoceptor (ADRB1-AB) to autoantibodies enriched from patient material. The functionality of these autoantibodies was tested in a cell based assay for comparison and their structural appearance was investigated using 2D gel electrophoresis. The ELISA showed a limit of detection for ADRB1-AB of about 1.5 nmol antibody/L when spiked in human control serum and only about 25 nmol/L when spiked in species identical (goat) matrix material. When applied to samples of human origin, the ELISA failed to identify the specific beta1-AABs. A low concentration of beta1-AAB, together with structural inconsistency of the patient originated samples as seen from the 2D Gel appearance, might contribute to the failure of the peptide based ELISA technology to detect human beta1-AABs.
Abe, Takeo; Tsunoda, Shinichiro; Nishioka, Aki; Azuma, Kouta; Tsuboi, Kazuyuki; Ogita, Chie; Yokoyama, Yuichi; Furukawa, Tetsuya; Maruoka, Momo; Tamura, Masao; Yoshikawa, Takahiro; Saito, Atsushi; Sekiguchi, Masahiro; Azuma, Naoto; Kitano, Masayasu; Matsui, Kiyoshi; Hosono, Yuji; Nakashima, Ran; Ohmura, Koichiro; Mimori, Tsuneyo; Sano, Hajime
2016-01-01
Anti-aminoacyl-tRNA synthetase (ARS) antibody is one of the myositis-specific autoantibodies to make a diagnosis of polymyositis (PM) and dermatomyositis (DM). Recently a new enzyme-linked immunosorbent assay (ELISA) kit of concurrently detected anti-ARS antibodies (anti-Jo-1, anti-PL-7, anti-PL-12, anti-EJ and anti-KS) have become to measure in the clinical setting. To evaluate the reliability of this ELISA kit, we measured anti-ARS antibodies in 75 PM and DM patients using by this ELISA assay and compared them with the results by RNA immunoprecipitation assay. Between the measurements of anti-PL-7, anti-PL-12, anti-EJ and anti-KS autoantibodies by ELISA assay and RNA-IP assay, the concordance rate of reproducibility is 95.1% and the positive agreement rate is 90.9% and negative agreement rate is 96.0% and kappa statistic is 0.841. Between the measurements of existing anti-Jo-1 antibody ELISA kit and anti-ARS antibody ELISA kit, the concordance rate of reproducibility is 96.9%, the positive agreement rate is 100%, negative agreement rate is 96.1% and kappa statistic is 0.909. The lung involvement in patients with PM and DM patients are positive of anti-ARS antibodies and anti-melanoma differentiation associated gene5 (MDA5) antibody at a rate around 70%. Then most life-threatening ILD with anti-MDA5 positive clinically amyopathic dermatomyositis patients could be highly guessed when anti-ARS antibodies are negative.
NASA Astrophysics Data System (ADS)
Lin, Margaret; Krawitz, Denise; Callahan, Matthew D.; Deperalta, Galahad; Wecksler, Aaron T.
2018-03-01
We describe epitope mapping data using multiple covalent labeling footprinting-mass spectrometry (MS) techniques coupled with negative stain transmission electron microscopy (TEM) data to analyze the antibody-antigen interactions in a sandwich enzyme-linked immunosorbant assay (ELISA). Our hydroxyl radical footprinting-MS data using fast photochemical oxidation of proteins (FPOP) indicates suppression of labeling across the antigen upon binding either of the monoclonal antibodies (mAbs) utilized in the ELISA. Combining these data with Western blot analysis enabled the identification of the putative epitopes that appeared to span regions containing N-linked glycans. An additional structural mapping technique, carboxyl group footprinting-mass spectrometry using glycine ethyl ester (GEE) labeling, was used to confirm the epitopes. Deglycosylation of the antigen resulted in loss of potency in the ELISA, supporting the FPOP and GEE labeling data by indicating N-linked glycans are necessary for antigen binding. Finally, mapping of the epitopes onto the antigen crystal structure revealed an approximate 90° relative spatial orientation, optimal for a noncompetitive binding ELISA. TEM data shows both linear and diamond antibody-antigen complexes with a similar binding orientation as predicted from the two footprinting-MS techniques. This study is the first of its kind to utilize multiple bottom-up footprinting-MS techniques and TEM visualization to characterize the monoclonal antibody-antigen binding interactions of critical reagents used in a quality control (QC) lot-release ELISA. [Figure not available: see fulltext.
Sandwich enzyme-linked immunosorbent assay for naringin.
Qu, Huihua; Wang, Xueqian; Qu, Baoping; Kong, Hui; Zhang, Yue; Shan, Wenchao; Cheng, Jinjun; Wang, Qingguo; Zhao, Yan
2016-01-15
Among the currently used immunoassay techniques, sandwich ELISA exhibits higher specificity, lower cross-reactivity, and a wider working range compared to the corresponding competitive assays. However, it is difficult to obtain a pair of antibodies that can simultaneously bind to two epitopes of a molecule with a molecular weight of less than 1000 Da. Naringin (Nar) is a flavonoid with a molecular mass of 580 Da. The main aim of this study was to develop a sandwich ELISA for detecting Nar. Two hybridomas secreting anti-Nar monoclonal antibodies (mAbs) were produced by fusing splenocytes from a mouse immunised against Nar-bovine serum albumin (BSA) conjugated with a hypoxanthine-aminopterin-thymidine (HAT)-sensitive mouse myeloma cell line; a sandwich ELISA for detecting Nar was developed using these two well-characterised anti-Nar mAbs. The performance of the sandwich assay was further evaluated by limit of detection (LOD), limit of quantification (LOQ), recovery, and interference analyses. A dose-response curve to Nar was obtained with an LOD of 6.78 ng mL(-1) and an LOQ of 13.47 ng mL(-1). The inter-assay and intra-assay coefficients of variation were 4.32% and 7.48%, respectively. The recovery rate of Nar from concentrated Fructus aurantii granules was 83.63%. A high correlation was obtained between HPLC and sandwich ELISA. These results demonstrate that the sandwich ELISA method has higher specificity for Nar than indirect competitive ELISA. Copyright © 2015 Elsevier B.V. All rights reserved.
Heida, Anke; Knol, Mariska; Kobold, Anneke Muller; Bootsman, Josette; Dijkstra, Gerard; van Rheenen, Patrick F
2017-11-01
An increasing number of physicians use repeated measurements of stool calprotectin to monitor intestinal inflammation in patients with inflammatory bowel diseases (IBDs). A lateral flow-based rapid test allows patients to measure their own stool calprotectin values at home. The test comes with a software application (IBDoc; Bühlmann Laboratories AG, Schönenbuch, Switzerland) that turns a smartphone camera into a results reader. We compared results from this method with those from the hospital-based reader (Quantum Blue; Bühlmann Laboratories AG) and enzyme-linked immunosorbent assay (ELISA) analysis. In a single-center comparison study, we asked 101 participants (10 years of age or older) in the Netherlands to perform the IBDoc measurement on stool samples collected at home, from June 2015 to October 2016. Participants then sent the residual extraction fluid and a fresh specimen from the same bowel movement to our pediatric and adult IBD center at the University Medical Center Groningen, where the level of calprotectin was measured by the Quantum Blue reader and ELISA analysis, respectively. The primary outcome was the agreement of results between IBDoc and the Quantum Blue and ELISA analyses, determined by Bland-Altman plot analysis. We received 152 IBDoc results, 138 samples of residual extraction fluid for Quantum Blue analysis, and 170 fresh stool samples for ELISA analysis. Spearman's rank correlation coefficient was 0.94 for results obtained by IBDoc vs Quantum Blue and 0.85 for results obtained by IBDoc vs ELISA. At the low range of calprotectin level (<500 μg/g), 91% of IBDoc-Quantum Blue results were within the predefined limits of agreement (±100 μg/g), and 71% of IBDoc-ELISA results were in agreement. At the high range of calprotectin level (≥500 μg/g), 81% of IBDoc-Quantum Blue results were within the predefined limits of agreement (±200 μg/g) and 64% of IBDoc-ELISA results were in agreement. Measurements of fecal levels of calprotectin made with home-based lateral flow method were in agreement with measurements made by Quantum Blue and ELISA, as long as concentrations were <500 μg/g. For patients with concentrations of fecal calprotectin above this level, findings from IBDoc should be confirmed by another method. (Netherlands Trial Registration Number: NTR5133). Copyright © 2017 AGA Institute. Published by Elsevier Inc. All rights reserved.
Bosnjakovic, Admira; Mishra, Manoj K.; Han, Hye Jung; Romero, Roberto; Kannan, Rangaramanujam M.
2012-01-01
A dendrimer-based sandwich type enzyme-linked immunosorbent assay (ELISA) was developed for the improved detection of recombinant human tumor necrosis factor-alpha (TNF-α) for early diagnosis of perinatal diseases. Hydroxyl-terminated generation four poly(amidoamine) dendrimer (G4-OH) was used for the development of a solid phase bio-sensing platform. The surface of the ELISA plate was modified with polyethylene-glycol (PEG) and thiol-functionalized G4-OH was immobilized on the PEG-functionalized plate. A capture antibody was oxidized and covalently immobilized onto the dendrimer-modified ELISA plate, which provides favorable orientation for the antigen binding sites towards the analyte. The dendrimer-modified plate showed enhanced sensitivity, and the detection limit for TNF-α was found to be 0.48 pg mL−1, which is significantly better than the commercially available ELISA kit. The selectivity of the dendrimer-modified ELISA plate was further evaluated with a mixture of cytokines, which showed results for similar to that of TNF-α alone. The modified plate provides a greater opportunity for the detection of a wide range of cytokines and biomarkers. PMID:22365129