Sample records for elisa microarray assay

  1. Sandwich ELISA Microarrays: Generating Reliable and Reproducible Assays for High-Throughput Screens

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gonzalez, Rachel M.; Varnum, Susan M.; Zangar, Richard C.

    The sandwich ELISA microarray is a powerful screening tool in biomarker discovery and validation due to its ability to simultaneously probe for multiple proteins in a miniaturized assay. The technical challenges of generating and processing the arrays are numerous. However, careful attention to possible pitfalls in the development of your antibody microarray assay can overcome these challenges. In this chapter, we describe in detail the steps that are involved in generating a reliable and reproducible sandwich ELISA microarray assay.

  2. ELISA-BASE: An Integrated Bioinformatics Tool for Analyzing and Tracking ELISA Microarray Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    White, Amanda M.; Collett, James L.; Seurynck-Servoss, Shannon L.

    ELISA-BASE is an open-source database for capturing, organizing and analyzing protein enzyme-linked immunosorbent assay (ELISA) microarray data. ELISA-BASE is an extension of the BioArray Soft-ware Environment (BASE) database system, which was developed for DNA microarrays. In order to make BASE suitable for protein microarray experiments, we developed several plugins for importing and analyzing quantitative ELISA microarray data. Most notably, our Protein Microarray Analysis Tool (ProMAT) for processing quantita-tive ELISA data is now available as a plugin to the database.

  3. Protein microarray with horseradish peroxidase chemiluminescence for quantification of serum α-fetoprotein.

    PubMed

    Zhao, Yuanshun; Zhang, Yonghong; Lin, Dongdong; Li, Kang; Yin, Chengzeng; Liu, Xiuhong; Jin, Boxun; Sun, Libo; Liu, Jinhua; Zhang, Aiying; Li, Ning

    2015-10-01

    To develop and evaluate a protein microarray assay with horseradish peroxidase (HRP) chemiluminescence for quantification of α-fetoprotein (AFP) in serum from patients with hepatocellular carcinoma (HCC). A protein microarray assay for AFP was developed. Serum was collected from patients with HCC and healthy control subjects. AFP was quantified using protein microarray and enzyme-linked immunosorbent assay (ELISA). Serum AFP concentrations determined via protein microarray were positively correlated (r = 0.973) with those determined via ELISA in patients with HCC (n = 60) and healthy control subjects (n = 30). Protein microarray showed 80% sensitivity and 100% specificity for HCC diagnosis. ELISA had 83.3% sensitivity and 100% specificity. Protein microarray effectively distinguished between patients with HCC and healthy control subjects (area under ROC curve 0.974; 95% CI 0.000, 1.000). Protein microarray is a rapid, simple and low-cost alternative to ELISA for detecting AFP in human serum. © The Author(s) 2015.

  4. Development and Validation of Sandwich ELISA Microarrays with Minimal Assay Interference

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gonzalez, Rachel M.; Servoss, Shannon; Crowley, Sheila A.

    Sandwich enzyme-linked immunosorbent assay (ELISA) microarrays are emerging as a strong candidate platform for multiplex biomarker analysis because of the ELISA’s ability to quantitatively measure rare proteins in complex biological fluids. Advantages of this platform are high-throughput potential, assay sensitivity and stringency, and the similarity to the standard ELISA test, which facilitates assay transfer from a research setting to a clinical laboratory. However, a major concern with the multiplexing of ELISAs is maintaining high assay specificity. In this study, we systematically determine the amount of assay interference and noise contributed by individual components of the multiplexed 24-assay system. We findmore » that non-specific reagent cross-reactivity problems are relatively rare. We did identify the presence of contaminant antigens in a “purified antigen”. We tested the validated ELISA microarray chip using paired serum samples that had been collected from four women at a 6-month interval. This analysis demonstrated that protein levels typically vary much more between individuals then within an individual over time, a result which suggests that longitudinal studies may be useful in controlling for biomarker variability across a population. Overall, this research demonstrates the importance of a stringent screening protocol and the value of optimizing the antibody and antigen concentrations when designing chips for ELISA microarrays.« less

  5. A Protein Microarray ELISA for the Detection of Botulinum neurotoxin A

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Varnum, Susan M.

    An enzyme-linked immunosorbent assay (ELISA) microarray was developed for the specific and sensitive detection of botulinum neurotoxin A (BoNT/A), using high-affinity recombinant monoclonal antibodies against the receptor binding domain of the heavy chain of BoNT/A. The ELISA microarray assay, because of its sensitivity, offers a screening test with detection limits comparable to the mouse bioassay, with results available in hours instead of days.

  6. Analysis of High-Throughput ELISA Microarray Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    White, Amanda M.; Daly, Don S.; Zangar, Richard C.

    Our research group develops analytical methods and software for the high-throughput analysis of quantitative enzyme-linked immunosorbent assay (ELISA) microarrays. ELISA microarrays differ from DNA microarrays in several fundamental aspects and most algorithms for analysis of DNA microarray data are not applicable to ELISA microarrays. In this review, we provide an overview of the steps involved in ELISA microarray data analysis and how the statistically sound algorithms we have developed provide an integrated software suite to address the needs of each data-processing step. The algorithms discussed are available in a set of open-source software tools (http://www.pnl.gov/statistics/ProMAT).

  7. Evaluating concentration estimation errors in ELISA microarray experiments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Daly, Don S.; White, Amanda M.; Varnum, Susan M.

    Enzyme-linked immunosorbent assay (ELISA) is a standard immunoassay to predict a protein concentration in a sample. Deploying ELISA in a microarray format permits simultaneous prediction of the concentrations of numerous proteins in a small sample. These predictions, however, are uncertain due to processing error and biological variability. Evaluating prediction error is critical to interpreting biological significance and improving the ELISA microarray process. Evaluating prediction error must be automated to realize a reliable high-throughput ELISA microarray system. Methods: In this paper, we present a statistical method based on propagation of error to evaluate prediction errors in the ELISA microarray process. Althoughmore » propagation of error is central to this method, it is effective only when comparable data are available. Therefore, we briefly discuss the roles of experimental design, data screening, normalization and statistical diagnostics when evaluating ELISA microarray prediction errors. We use an ELISA microarray investigation of breast cancer biomarkers to illustrate the evaluation of prediction errors. The illustration begins with a description of the design and resulting data, followed by a brief discussion of data screening and normalization. In our illustration, we fit a standard curve to the screened and normalized data, review the modeling diagnostics, and apply propagation of error.« less

  8. Performance of seven serological assays for diagnosing tularemia

    PubMed Central

    2014-01-01

    Background Tularemia is a rare zoonotic disease caused by the Gram-negative bacterium Francisella tularensis. Serology is frequently the preferred diagnostic approach, because the pathogen is highly infectious and difficult to cultivate. The aim of this retrospective study was to determine the diagnostic accuracy of tularemia specific tests. Methods The Serazym®Anti-Francisella tularensis ELISA, Serion ELISA classic Francisella tularensis IgG/IgM, an in-house ELISA, the VIRapid® Tularemia immunochromatographic test, an in-house antigen microarray, and a Western Blot (WB) assay were evaluated. The diagnosis tularemia was established using a standard micro-agglutination assay. In total, 135 sera from a series of 110 consecutive tularemia patients were tested. Results The diagnostic sensitivity and diagnostic specificity of the tests were VIRapid (97.0% and 84.0%), Serion IgG (96.3% and 96.8%), Serion IgM (94.8% and 96.8%), Serazym (97.0% and 91.5%), in-house ELISA (95.6% and 76.6%), WB (93.3% and 83.0%), microarray (91.1% and 97.9%). Conclusions The diagnostic value of the commercial assays was proven, because the diagnostic accuracy was >90%. The diagnostic sensitivity of the in-house ELISA and the WB were acceptable, but the diagnostic accuracy was <90%. Interestingly, the antigen microarray test was very specific and had a very good positive predictive value. PMID:24885274

  9. The Thoc1 Ribonucleoprotein as a Novel Biomarker for Prostate Cancer Treatment Assignment

    DTIC Science & Technology

    2017-10-01

    PI Mohler). Immunostaining of prostate cancer biopsy specimen of patients who qualified for active surveillance is complete (PI Goodrich). ELISA assay...specimens for use in constructing tissue microarrays, developing and optimizing ELISA assays to detect Thoc1 protein and anti-Thoc1 autoantibodies...set of TMAs made from 700 patients available at RPCI has been immunostained for PMP22 (figure 5). ELISA assays for measuring pThoc1 and pThoc1

  10. The Thoc1 Ribonucleoprotein as a Novel Biomarker for Prostate Cancer Treatment Assignment

    DTIC Science & Technology

    2016-10-01

    patients on active surveillance is ongoing (PI Mohler). Developing ELISA assays for measuring pThoc1 and pThoc1 autoantibodies is complete (PI...assessment of 1146 patient specimens for use in constructing tissue microarrays, developing and optimizing ELISA assays to detect anti-Thoc1 autoantibodies...700 patients available at RPCI has been immunostained for PMP22 (figure 3). ELISA assays for measuring pThoc1 and pThoc1 autoantibodies have been

  11. Predicting protein concentrations with ELISA microarray assays, monotonic splines and Monte Carlo simulation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Daly, Don S.; Anderson, Kevin K.; White, Amanda M.

    Background: A microarray of enzyme-linked immunosorbent assays, or ELISA microarray, predicts simultaneously the concentrations of numerous proteins in a small sample. These predictions, however, are uncertain due to processing error and biological variability. Making sound biological inferences as well as improving the ELISA microarray process require require both concentration predictions and creditable estimates of their errors. Methods: We present a statistical method based on monotonic spline statistical models, penalized constrained least squares fitting (PCLS) and Monte Carlo simulation (MC) to predict concentrations and estimate prediction errors in ELISA microarray. PCLS restrains the flexible spline to a fit of assay intensitymore » that is a monotone function of protein concentration. With MC, both modeling and measurement errors are combined to estimate prediction error. The spline/PCLS/MC method is compared to a common method using simulated and real ELISA microarray data sets. Results: In contrast to the rigid logistic model, the flexible spline model gave credible fits in almost all test cases including troublesome cases with left and/or right censoring, or other asymmetries. For the real data sets, 61% of the spline predictions were more accurate than their comparable logistic predictions; especially the spline predictions at the extremes of the prediction curve. The relative errors of 50% of comparable spline and logistic predictions differed by less than 20%. Monte Carlo simulation rendered acceptable asymmetric prediction intervals for both spline and logistic models while propagation of error produced symmetric intervals that diverged unrealistically as the standard curves approached horizontal asymptotes. Conclusions: The spline/PCLS/MC method is a flexible, robust alternative to a logistic/NLS/propagation-of-error method to reliably predict protein concentrations and estimate their errors. The spline method simplifies model selection and fitting, and reliably estimates believable prediction errors. For the 50% of the real data sets fit well by both methods, spline and logistic predictions are practically indistinguishable, varying in accuracy by less than 15%. The spline method may be useful when automated prediction across simultaneous assays of numerous proteins must be applied routinely with minimal user intervention.« less

  12. Fluorescence-based bioassays for the detection and evaluation of food materials.

    PubMed

    Nishi, Kentaro; Isobe, Shin-Ichiro; Zhu, Yun; Kiyama, Ryoiti

    2015-10-13

    We summarize here the recent progress in fluorescence-based bioassays for the detection and evaluation of food materials by focusing on fluorescent dyes used in bioassays and applications of these assays for food safety, quality and efficacy. Fluorescent dyes have been used in various bioassays, such as biosensing, cell assay, energy transfer-based assay, probing, protein/immunological assay and microarray/biochip assay. Among the arrays used in microarray/biochip assay, fluorescence-based microarrays/biochips, such as antibody/protein microarrays, bead/suspension arrays, capillary/sensor arrays, DNA microarrays/polymerase chain reaction (PCR)-based arrays, glycan/lectin arrays, immunoassay/enzyme-linked immunosorbent assay (ELISA)-based arrays, microfluidic chips and tissue arrays, have been developed and used for the assessment of allergy/poisoning/toxicity, contamination and efficacy/mechanism, and quality control/safety. DNA microarray assays have been used widely for food safety and quality as well as searches for active components. DNA microarray-based gene expression profiling may be useful for such purposes due to its advantages in the evaluation of pathway-based intracellular signaling in response to food materials.

  13. Fluorescence-Based Bioassays for the Detection and Evaluation of Food Materials

    PubMed Central

    Nishi, Kentaro; Isobe, Shin-Ichiro; Zhu, Yun; Kiyama, Ryoiti

    2015-01-01

    We summarize here the recent progress in fluorescence-based bioassays for the detection and evaluation of food materials by focusing on fluorescent dyes used in bioassays and applications of these assays for food safety, quality and efficacy. Fluorescent dyes have been used in various bioassays, such as biosensing, cell assay, energy transfer-based assay, probing, protein/immunological assay and microarray/biochip assay. Among the arrays used in microarray/biochip assay, fluorescence-based microarrays/biochips, such as antibody/protein microarrays, bead/suspension arrays, capillary/sensor arrays, DNA microarrays/polymerase chain reaction (PCR)-based arrays, glycan/lectin arrays, immunoassay/enzyme-linked immunosorbent assay (ELISA)-based arrays, microfluidic chips and tissue arrays, have been developed and used for the assessment of allergy/poisoning/toxicity, contamination and efficacy/mechanism, and quality control/safety. DNA microarray assays have been used widely for food safety and quality as well as searches for active components. DNA microarray-based gene expression profiling may be useful for such purposes due to its advantages in the evaluation of pathway-based intracellular signaling in response to food materials. PMID:26473869

  14. A Protein Microarray for the Rapid Screening of Patients Suspected of Infection with Various Food-Borne Helminthiases

    PubMed Central

    Ai, Lin; Chen, Jun-Hu; Chen, Shao-Hong; Zhang, Yong-Nian; Cai, Yu-Chun; Zhu, Xing-Quan; Zhou, Xiao-Nong

    2012-01-01

    Background Food-borne helminthiases (FBHs) have become increasingly important due to frequent occurrence and worldwide distribution. There is increasing demand for developing more sensitive, high-throughput techniques for the simultaneous detection of multiple parasitic diseases due to limitations in differential clinical diagnosis of FBHs with similar symptoms. These infections are difficult to diagnose correctly by conventional diagnostic approaches including serological approaches. Methodology/Principal Findings In this study, antigens obtained from 5 parasite species, namely Cysticercus cellulosae, Angiostrongylus cantonensis, Paragonimus westermani, Trichinella spiralis and Spirometra sp., were semi-purified after immunoblotting. Sera from 365 human cases of helminthiasis and 80 healthy individuals were assayed with semi-purified antigens by both a protein microarray and the enzyme-linked immunosorbent assay (ELISA). The sensitivity, specificity and simplicity of each test for the end-user were evaluated. The specificity of the tests ranged from 97.0% (95% confidence interval (CI): 95.3–98.7%) to 100.0% (95% CI: 100.0%) in the protein microarray and from 97.7% (95% CI: 96.2–99.2%) to 100.0% (95% CI: 100.0%) in ELISA. The sensitivity varied from 85.7% (95% CI: 75.1–96.3%) to 92.1% (95% CI: 83.5–100.0%) in the protein microarray, while the corresponding values for ELISA were 82.0% (95% CI: 71.4–92.6%) to 92.1% (95% CI: 83.5–100.0%). Furthermore, the Youden index spanned from 0.83 to 0.92 in the protein microarray and from 0.80 to 0.92 in ELISA. For each parasite, the Youden index from the protein microarray was often slightly higher than the one from ELISA even though the same antigen was used. Conclusions/Significance The protein microarray platform is a convenient, versatile, high-throughput method that can easily be adapted to massive FBH screening. PMID:23209851

  15. ELISA microarray technology as a high-throughput system for cancer biomarker validation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zangar, Richard C.; Daly, Don S.; White, Amanda M.

    A large gap currently exists between the ability to discover potential biomarkers and the ability to assess the real value of these proteins for cancer screening. One major challenge in biomarker validation is the inherent variability in biomarker levels. This variability stems from the diversity across the human population and the considerable molecular heterogeneity between individual tumors, even those that originate from a single tissue. Another major challenge with cancer screening is that most cancers are rare in the general population, meaning that the specificity of an assay must be very high if the number of false positive is notmore » going to be much greater than the number of true positives. Because of these challenges with biomarker validation, it is necessary to analysis of thousands of samples before a clear idea of the utility of a screening assay can be determined. Enzyme-linked immunosorbent assay (ELISA) microarray technology can simultaneously quantify levels of multiple proteins and has the potential to accelerate biomarker validation. In this review, we discuss current ELISA microarray technology and the enabling advances needed to achieve the reproducibility and throughput that are required to evaluate cancer biomarkers.« less

  16. A Quick and Parallel Analytical Method Based on Quantum Dots Labeling for ToRCH-Related Antibodies

    NASA Astrophysics Data System (ADS)

    Yang, Hao; Guo, Qing; He, Rong; Li, Ding; Zhang, Xueqing; Bao, Chenchen; Hu, Hengyao; Cui, Daxiang

    2009-12-01

    Quantum dot is a special kind of nanomaterial composed of periodic groups of II-VI, III-V or IV-VI materials. Their high quantum yield, broad absorption with narrow photoluminescence spectra and high resistance to photobleaching, make them become a promising labeling substance in biological analysis. Here, we report a quick and parallel analytical method based on quantum dots for ToRCH-related antibodies including Toxoplasma gondii, Rubella virus, Cytomegalovirus and Herpes simplex virus type 1 (HSV1) and 2 (HSV2). Firstly, we fabricated the microarrays with the five kinds of ToRCH-related antigens and used CdTe quantum dots to label secondary antibody and then analyzed 100 specimens of randomly selected clinical sera from obstetric outpatients. The currently prevalent enzyme-linked immunosorbent assay (ELISA) kits were considered as “golden standard” for comparison. The results show that the quantum dots labeling-based ToRCH microarrays have comparable sensitivity and specificity with ELISA. Besides, the microarrays hold distinct advantages over ELISA test format in detection time, cost, operation and signal stability. Validated by the clinical assay, our quantum dots-based ToRCH microarrays have great potential in the detection of ToRCH-related pathogens.

  17. Profiling Humoral Immune Responses to Clostridium difficile-Specific Antigens by Protein Microarray Analysis.

    PubMed

    Negm, Ola H; Hamed, Mohamed R; Dilnot, Elizabeth M; Shone, Clifford C; Marszalowska, Izabela; Lynch, Mark; Loscher, Christine E; Edwards, Laura J; Tighe, Patrick J; Wilcox, Mark H; Monaghan, Tanya M

    2015-09-01

    Clostridium difficile is an anaerobic, Gram-positive, and spore-forming bacterium that is the leading worldwide infective cause of hospital-acquired and antibiotic-associated diarrhea. Several studies have reported associations between humoral immunity and the clinical course of C. difficile infection (CDI). Host humoral immune responses are determined using conventional enzyme-linked immunosorbent assay (ELISA) techniques. Herein, we report the first use of a novel protein microarray assay to determine systemic IgG antibody responses against a panel of highly purified C. difficile-specific antigens, including native toxins A and B (TcdA and TcdB, respectively), recombinant fragments of toxins A and B (TxA4 and TxB4, respectively), ribotype-specific surface layer proteins (SLPs; 001, 002, 027), and control proteins (tetanus toxoid and Candida albicans). Microarrays were probed with sera from a total of 327 individuals with CDI, cystic fibrosis without diarrhea, and healthy controls. For all antigens, precision profiles demonstrated <10% coefficient of variation (CV). Significant correlation was observed between microarray and ELISA in the quantification of antitoxin A and antitoxin B IgG. These results indicate that microarray is a suitable assay for defining humoral immune responses to C. difficile protein antigens and may have potential advantages in throughput, convenience, and cost. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  18. Profiling Humoral Immune Responses to Clostridium difficile-Specific Antigens by Protein Microarray Analysis

    PubMed Central

    Negm, Ola H.; Hamed, Mohamed R.; Dilnot, Elizabeth M.; Shone, Clifford C.; Marszalowska, Izabela; Lynch, Mark; Loscher, Christine E.; Edwards, Laura J.; Tighe, Patrick J.; Wilcox, Mark H.

    2015-01-01

    Clostridium difficile is an anaerobic, Gram-positive, and spore-forming bacterium that is the leading worldwide infective cause of hospital-acquired and antibiotic-associated diarrhea. Several studies have reported associations between humoral immunity and the clinical course of C. difficile infection (CDI). Host humoral immune responses are determined using conventional enzyme-linked immunosorbent assay (ELISA) techniques. Herein, we report the first use of a novel protein microarray assay to determine systemic IgG antibody responses against a panel of highly purified C. difficile-specific antigens, including native toxins A and B (TcdA and TcdB, respectively), recombinant fragments of toxins A and B (TxA4 and TxB4, respectively), ribotype-specific surface layer proteins (SLPs; 001, 002, 027), and control proteins (tetanus toxoid and Candida albicans). Microarrays were probed with sera from a total of 327 individuals with CDI, cystic fibrosis without diarrhea, and healthy controls. For all antigens, precision profiles demonstrated <10% coefficient of variation (CV). Significant correlation was observed between microarray and ELISA in the quantification of antitoxin A and antitoxin B IgG. These results indicate that microarray is a suitable assay for defining humoral immune responses to C. difficile protein antigens and may have potential advantages in throughput, convenience, and cost. PMID:26178385

  19. Development and application of a fluorescence protein microarray for detecting serum alpha-fetoprotein in patients with hepatocellular carcinoma.

    PubMed

    Zhang, Aiying; Yin, Chengzeng; Wang, Zhenshun; Zhang, Yonghong; Zhao, Yuanshun; Li, Ang; Sun, Huanqin; Lin, Dongdong; Li, Ning

    2016-12-01

    Objective To develop a simple, effective, time-saving and low-cost fluorescence protein microarray method for detecting serum alpha-fetoprotein (AFP) in patients with hepatocellular carcinoma (HCC). Method Non-contact piezoelectric print techniques were applied to fluorescence protein microarray to reduce the cost of prey antibody. Serum samples from patients with HCC and healthy control subjects were collected and evaluated for the presence of AFP using a novel fluorescence protein microarray. To validate the fluorescence protein microarray, serum samples were tested for AFP using an enzyme-linked immunosorbent assay (ELISA). Results A total of 110 serum samples from patients with HCC ( n = 65) and healthy control subjects ( n = 45) were analysed. When the AFP cut-off value was set at 20 ng/ml, the fluorescence protein microarray had a sensitivity of 91.67% and a specificity of 93.24% for detecting serum AFP. Serum AFP quantified via fluorescence protein microarray had a similar diagnostic performance compared with ELISA in distinguishing patients with HCC from healthy control subjects (area under receiver operating characteristic curve: 0.906 for fluorescence protein microarray; 0.880 for ELISA). Conclusion A fluorescence protein microarray method was developed for detecting serum AFP in patients with HCC.

  20. Development and application of a fluorescence protein microarray for detecting serum alpha-fetoprotein in patients with hepatocellular carcinoma

    PubMed Central

    Zhang, Aiying; Yin, Chengzeng; Wang, Zhenshun; Zhang, Yonghong; Zhao, Yuanshun; Li, Ang; Sun, Huanqin; Lin, Dongdong

    2016-01-01

    Objective To develop a simple, effective, time-saving and low-cost fluorescence protein microarray method for detecting serum alpha-fetoprotein (AFP) in patients with hepatocellular carcinoma (HCC). Method Non-contact piezoelectric print techniques were applied to fluorescence protein microarray to reduce the cost of prey antibody. Serum samples from patients with HCC and healthy control subjects were collected and evaluated for the presence of AFP using a novel fluorescence protein microarray. To validate the fluorescence protein microarray, serum samples were tested for AFP using an enzyme-linked immunosorbent assay (ELISA). Results A total of 110 serum samples from patients with HCC (n = 65) and healthy control subjects (n = 45) were analysed. When the AFP cut-off value was set at 20 ng/ml, the fluorescence protein microarray had a sensitivity of 91.67% and a specificity of 93.24% for detecting serum AFP. Serum AFP quantified via fluorescence protein microarray had a similar diagnostic performance compared with ELISA in distinguishing patients with HCC from healthy control subjects (area under receiver operating characteristic curve: 0.906 for fluorescence protein microarray; 0.880 for ELISA). Conclusion A fluorescence protein microarray method was developed for detecting serum AFP in patients with HCC. PMID:27885040

  1. Comparison of mucosal lining fluid sampling methods and influenza-specific IgA detection assays for use in human studies of influenza immunity.

    PubMed

    de Silva, Thushan I; Gould, Victoria; Mohammed, Nuredin I; Cope, Alethea; Meijer, Adam; Zutt, Ilse; Reimerink, Johan; Kampmann, Beate; Hoschler, Katja; Zambon, Maria; Tregoning, John S

    2017-10-01

    We need greater understanding of the mechanisms underlying protection against influenza virus to develop more effective vaccines. To do this, we need better, more reproducible methods of sampling the nasal mucosa. The aim of the current study was to compare levels of influenza virus A subtype-specific IgA collected using three different methods of nasal sampling. Samples were collected from healthy adult volunteers before and after LAIV immunization by nasal wash, flocked swabs and Synthetic Absorptive Matrix (SAM) strips. Influenza A virus subtype-specific IgA levels were measured by haemagglutinin binding ELISA or haemagglutinin binding microarray and the functional response was assessed by microneutralization. Nasosorption using SAM strips lead to the recovery of a more concentrated sample of material, with a significantly higher level of total and influenza H1-specific IgA. However, an equivalent percentage of specific IgA was observed with all sampling methods when normalized to the total IgA. Responses measured using a recently developed antibody microarray platform, which allows evaluation of binding to multiple influenza strains simultaneously with small sample volumes, were compared to ELISA. There was a good correlation between ELISA and microarray values. Material recovered from SAM strips was weakly neutralizing when used in an in vitro assay, with a modest correlation between the level of IgA measured by ELISA and neutralization, but a greater correlation between microarray-measured IgA and neutralizing activity. In conclusion we have tested three different methods of nasal sampling and show that flocked swabs and novel SAM strips are appropriate alternatives to traditional nasal washes for assessment of mucosal influenza humoral immunity. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Development of an ELISA microarray assay for the sensitive and simultaneous detection of ten biodefense toxins.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jenko, Kathryn; Zhang, Yanfeng; Kostenko, Yulia

    Plant and microbial toxins are considered bioterrorism threat agents because of their extreme toxicity and/or ease of availability. Additionally, some of these toxins are increasingly responsible for accidental food poisonings. The current study utilized an ELISA-based protein antibody microarray for the multiplexed detection of ten biothreat toxins, botulinum neurotoxins (BoNT) A, B, C, D, E, F, ricin, shiga toxins 1 and 2 (Stx), and staphylococcus enterotoxin B (SEB), in buffer and complex biological matrices. The multiplexed assay displayed a sensitivity of 1.3 pg/mL (BoNT/A, BoNT/B, SEB, Stx-1 and Stx-2), 3.3 pg/mL (BoNT/C, BoNT/E, BoNT/F) and 8.2 pg/mL (BoNT/D, ricin). Allmore » assays demonstrated high accuracy (75-120 percent recovery) and reproducibility (most coefficients of variation < 20%). Quantification curves for the ten toxins were also evaluated in clinical samples (serum, plasma, nasal fluid, saliva, stool, and urine) and environmental samples (apple juice, milk and baby food) with overall minimal matrix effects. The multiplex assays were highly specific, with little crossreactivity observed between the selected toxin antibodies. The results demonstrate a multiplex microarray that improves current immunoassay sensitivity for biological warfare agents in buffer, clinical, and environmental samples.« less

  3. Simultaneous and sensitive detection of six serotypes of botulinum neurotoxin using enzyme-linked immunosorbent assay-based protein antibody microarrays

    PubMed Central

    Zhang, Yanfeng; Lou, Jianlong; Jenko, Kathy L.; Marks, James D.; Varnum, Susan M.

    2012-01-01

    Botulinum neurotoxins (BoNTs), produced by Clostridium botulinum, are a group of seven (A–G) immunologically distinct proteins and cause the paralytic disease botulism. These toxins are the most poisonous substances known to humans and are potential bioweapon agents. Therefore, it is necessary to develop highly sensitive assays for the detection of BoNTs in both clinical and environmental samples. In the current study, we have developed an enzyme-linked immunosorbent assay (ELISA)-based protein antibody microarray for the sensitive and simultaneous detection of BoNT serotypes A, B, C, D, E, and F. With engineered high-affinity antibodies, the BoNT assays have sensitivities in buffer ranging from 1.3 fM (0.2 pg/ml) to 14.7 fM (2.2 pg/ml). Using clinical and food matrices (serum and milk), the microarray is capable of detecting BoNT serotypes A to F to similar levels as in standard buffer. Cross-reactivity between assays for individual serotype was also analyzed. These simultaneous, rapid, and sensitive assays have the potential to measure botulinum toxins in a high-throughput manner in complex clinical, food, and environmental samples. PMID:22935296

  4. Inkjet-printed point-of-care immunoassay on a nanoscale polymer brush enables subpicomolar detection of analytes in blood

    NASA Astrophysics Data System (ADS)

    Joh, Daniel Y.; Hucknall, Angus M.; Wei, Qingshan; Mason, Kelly A.; Lund, Margaret L.; Fontes, Cassio M.; Hill, Ryan T.; Blair, Rebecca; Zimmers, Zackary; Achar, Rohan K.; Tseng, Derek; Gordan, Raluca; Freemark, Michael; Ozcan, Aydogan; Chilkoti, Ashutosh

    2017-08-01

    The ELISA is the mainstay for sensitive and quantitative detection of protein analytes. Despite its utility, ELISA is time-consuming, resource-intensive, and infrastructure-dependent, limiting its availability in resource-limited regions. Here, we describe a self-contained immunoassay platform (the “D4 assay”) that converts the sandwich immunoassay into a point-of-care test (POCT). The D4 assay is fabricated by inkjet printing assay reagents as microarrays on nanoscale polymer brushes on glass chips, so that all reagents are “on-chip,” and these chips show durable storage stability without cold storage. The D4 assay can interrogate multiple analytes from a drop of blood, is compatible with a smartphone detector, and displays analytical figures of merit that are comparable to standard laboratory-based ELISA in whole blood. These attributes of the D4 POCT have the potential to democratize access to high-performance immunoassays in resource-limited settings without sacrificing their performance.

  5. Simultaneous and sensitive detection of six serotypes of botulinum neurotoxin using enzyme-linked immunosorbent assay-based protein antibody microarrays

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Yanfeng; Lou, Jianlong; Jenko, Kathryn L.

    2012-11-15

    Botulinum neurotoxins (BoNTs), produced by Clostridium botulinum, are a group of seven (A-G) immunologically distinct proteins and cause the paralytic disease botulism. These toxins are the most poisonous substances known to humans and are potential bioweapon agents. Therefore, it is necessary to develop highly sensitive assays for the detection of BoNTs in both clinical and environmental samples. In the present study, we have developed an ELISA-based protein antibody microarray for the sensitive and simultaneous detection of BoNT serotype A, B, C, D, E and F. With engineered high-affinity antibodies, the assays have sensitivities in buffer of 8 fM (1.2 pg/mL)more » for serotypes A and B, and 32 fM (4.9 pg/mL) for serotypes C, D, E, and F. Using clinical and environmental samples (serum and milk), the microarray is capable of detecting BoNT/A-F to the same levels as in standard buffer. Cross reactivity between assays for individual serotype was also analyzed. These simultaneous, rapid, and sensitive assays have the potential to measure botulinum toxins in a high-throughput manner in complex clinical or environmental samples.« less

  6. A novel piezoelectric quartz micro-array immunosensor for detection of immunoglobulinE.

    PubMed

    Yao, Chunyan; Chen, Qinghai; Chen, Ming; Zhang, Bo; Luo, Yang; Huang, Qing; Huang, Junfu; Fu, Weiling

    2006-12-01

    A novel multi-channel 2 x 5 model of piezoelectric (PZ) micro-array immunosensor has been developed for quantitative detection of human immunoglobulinE (IgE) in serum. Every crystal unit of the fabricated piezoelectric IgE micro-array immunosensor can oscillate without interfering each other. A multi-channel 2 x 5 model micro-array immunosensor as compared with the traditional one-channel immunosensor can provide eight times higher detection speeds for IgE assay. The anti-IgE antibody is deposited on the gold electrode's surface of 10 MHz AT-cut quartz crystals by SPA (staphylococcal protein A), and serves as an antibody recognizing layer. The highly ordered antibody monolayers ensure well-controlled surface structure and offer many advantages to the performance of the sensor. The uniform amount of antibody monolayer coated by the SPA is good, and non-specific reaction caused by other immunoglobulin in sample is found. The fabricated PZ immunosensor can be used for human IgE determination in the range of 5-300 IU/ml with high precision (CV is 4%). 50 human serum samples were detected by the micro-array immunosensor, and the results agreed well with those given by the commercially ELISA test kits. The correlation coefficient is 0.94 between ELISA and PZ immunosensor. After regeneration with NaOH the coated immunosensor can be reused 6 times without appreciable loss of activity.

  7. Identification of new autoantigens for primary biliary cirrhosis using human proteome microarrays.

    PubMed

    Hu, Chao-Jun; Song, Guang; Huang, Wei; Liu, Guo-Zhen; Deng, Chui-Wen; Zeng, Hai-Pan; Wang, Li; Zhang, Feng-Chun; Zhang, Xuan; Jeong, Jun Seop; Blackshaw, Seth; Jiang, Li-Zhi; Zhu, Heng; Wu, Lin; Li, Yong-Zhe

    2012-09-01

    Primary biliary cirrhosis (PBC) is a chronic cholestatic liver disease of unknown etiology and is considered to be an autoimmune disease. Autoantibodies are important tools for accurate diagnosis of PBC. Here, we employed serum profiling analysis using a human proteome microarray composed of about 17,000 full-length unique proteins and identified 23 proteins that correlated with PBC. To validate these results, we fabricated a PBC-focused microarray with 21 of these newly identified candidates and nine additional known PBC antigens. By screening the PBC microarrays with additional cohorts of 191 PBC patients and 321 controls (43 autoimmune hepatitis, 55 hepatitis B virus, 31 hepatitis C virus, 48 rheumatoid arthritis, 45 systematic lupus erythematosus, 49 systemic sclerosis, and 50 healthy), six proteins were confirmed as novel PBC autoantigens with high sensitivities and specificities, including hexokinase-1 (isoforms I and II), Kelch-like protein 7, Kelch-like protein 12, zinc finger and BTB domain-containing protein 2, and eukaryotic translation initiation factor 2C, subunit 1. To facilitate clinical diagnosis, we developed ELISA for Kelch-like protein 12 and zinc finger and BTB domain-containing protein 2 and tested large cohorts (297 PBC and 637 control sera) to confirm the sensitivities and specificities observed in the microarray-based assays. In conclusion, our research showed that a strategy using high content protein microarray combined with a smaller but more focused protein microarray can effectively identify and validate novel PBC-specific autoantigens and has the capacity to be translated to clinical diagnosis by means of an ELISA-based method.

  8. A Rational Approach for Discovering and Validating Cancer Markers in Very Small Samples Using Mass Spectrometry and ELISA Microarrays

    DOE PAGES

    Zangar, Richard C.; Varnum, Susan M.; Covington, Chandice Y.; ...

    2004-01-01

    Identifying useful markers of cancer can be problematic due to limited amounts of sample. Some samples such as nipple aspirate fluid (NAF) or early-stage tumors are inherently small. Other samples such as serum are collected in larger volumes but archives of these samples are very valuable and only small amounts of each sample may be available for a single study. Also, given the diverse nature of cancer and the inherent variability in individual protein levels, it seems likely that the best approach to screen for cancer will be to determine the profile of a battery of proteins. As a result,more » a major challenge in identifying protein markers of disease is the ability to screen many proteins using very small amounts of sample. In this review, we outline some technological advances in proteomics that greatly advance this capability. Specifically, we propose a strategy for identifying markers of breast cancer in NAF that utilizes mass spectrometry (MS) to simultaneously screen hundreds or thousands of proteins in each sample. The best potential markers identified by the MS analysis can then be extensively characterized using an ELISA microarray assay. Because the microarray analysis is quantitative and large numbers of samples can be efficiently analyzed, this approach offers the ability to rapidly assess a battery of selected proteins in a manner that is directly relevant to traditional clinical assays.« less

  9. Proteome Analysis and Serological Characterization of Surface-Exposed Proteins of Rickettsia heilongjiangensis

    PubMed Central

    Qi, Yong; Xiong, Xiaolu; Wang, Xile; Duan, Changsong; Jia, Yinjun; Jiao, Jun; Gong, Wenping; Wen, Bohai

    2013-01-01

    Background Rickettsia heilongjiangensis, the agent of Far-Eastern spotted fever (FESF), is an obligate intracellular bacterium. The surface-exposed proteins (SEPs) of rickettsiae are involved in rickettsial adherence to and invasion of host cells, intracellular bacterial growth, and/or interaction with immune cells. They are also potential molecular candidates for the development of diagnostic reagents and vaccines against rickettsiosis. Methods R. heilongjiangensis SEPs were identified by biotin-streptavidin affinity purification and 2D electrophoreses coupled with ESI-MS/MS. Recombinant SEPs were probed with various sera to analyze their serological characteristics using a protein microarray and an enzyme-linked immune sorbent assay (ELISA). Results Twenty-five SEPs were identified, most of which were predicted to reside on the surface of R. heilongjiangensis cells. Bioinformatics analysis suggests that these proteins could be involved in bacterial pathogenesis. Eleven of the 25 SEPs were recognized as major seroreactive antigens by sera from R. heilongjiangensis-infected mice and FESF patients. Among the major seroreactive SEPs, microarray assays and/or ELISAs revealed that GroEL, OmpA-2, OmpB-3, PrsA, RplY, RpsB, SurA and YbgF had modest sensitivity and specificity for recognizing R. heilongjiangensis infection and/or spotted fever. Conclusions Many of the SEPs identified herein have potentially important roles in R. heilongjiangensis pathogenicity. Some of them have potential as serodiagnostic antigens or as subunit vaccine antigens against the disease. PMID:23894656

  10. Protein Microarray Analysis in Patients With Asthma*

    PubMed Central

    Kim, Hyo-Bin; Kim, Chang-Keun; Iijima, Koji; Kobayashi, Takao; Kita, Hirohito

    2010-01-01

    Background Microarray technology offers a new opportunity to gain insight into global gene and protein expression profiles in asthma. To identify novel factors produced in the asthmatic airway, we analyzed sputum samples by using a membrane-based human cytokine microarray technology in patients with bronchial asthma (BA). Methods Induced sputum was obtained from 28 BA subjects, 20 nonasthmatic atopic control (AC) subjects, and 38 nonasthmatic nonatopic normal control (NC) subjects. The microarray samples of subjects were randomly selected from nine BA subjects, three AC subjects, and six NC subjects. Sputum supernatants were analyzed using a custom human cytokine array (RayBio Custom Human Cytokine Array; RayBiotech; Norcross, GA) designed to analyze 79 specific cytokines simultaneously. The levels of growth-regulated oncogene (GRO)-α, eotaxin-2, and pulmonary and activation-regulated chemokine (PARC)/CCL18 were measured by sandwich enzyme-linked immunosorbent assays (ELISAs), and eosinophil-derived neurotoxin (EDN) was measured by radioimmunoassay. Results By microarray, the signal intensities for GRO-α, eotaxin-2, and PARC were significantly higher in BA subjects than in AC and NC subjects (p = 0.036, p = 0.042, and p = 0.033, respectively). By ELISA, the sputum PARC protein levels were significantly higher in BA subjects than in AC and NC subjects (p < 0.0001). Furthermore, PARC levels correlated significantly with sputum eosinophil percentages (r = 0.570, p < 0.0001) and the levels of EDN(r = 0.633, p < 0.0001), the regulated upon activation, normal T cell expressed and secreted cytokine (r = 0.440, p < 0.001), interleukin-4 (r = 0.415, p < 0.01), and interferon-γ (r = 0.491, p < 0.001). Conclusions By a nonbiased screening approach, a chemokine, PARC, is elevated in sputum specimens from patients with asthma. PARC may play important roles in development of airway eosinophilic inflammation in asthma. PMID:19017877

  11. Generation of Antigen Microarrays to Screen for Autoantibodies in Heart Failure and Heart Transplantation.

    PubMed

    Chruscinski, Andrzej; Huang, Flora Y Y; Nguyen, Albert; Lioe, Jocelyn; Tumiati, Laura C; Kozuszko, Stella; Tinckam, Kathryn J; Rao, Vivek; Dunn, Shannon E; Persinger, Michael A; Levy, Gary A; Ross, Heather J

    2016-01-01

    Autoantibodies directed against endogenous proteins including contractile proteins and endothelial antigens are frequently detected in patients with heart failure and after heart transplantation. There is evidence that these autoantibodies contribute to cardiac dysfunction and correlate with clinical outcomes. Currently, autoantibodies are detected in patient sera using individual ELISA assays (one for each antigen). Thus, screening for many individual autoantibodies is laborious and consumes a large amount of patient sample. To better capture the broad-scale antibody reactivities that occur in heart failure and post-transplant, we developed a custom antigen microarray technique that can simultaneously measure IgM and IgG reactivities against 64 unique antigens using just five microliters of patient serum. We first demonstrated that our antigen microarray technique displayed enhanced sensitivity to detect autoantibodies compared to the traditional ELISA method. We then piloted this technique using two sets of samples that were obtained at our institution. In the first retrospective study, we profiled pre-transplant sera from 24 heart failure patients who subsequently received heart transplants. We identified 8 antibody reactivities that were higher in patients who developed cellular rejection (2 or more episodes of grade 2R rejection in first year after transplant as defined by revised criteria from the International Society for Heart and Lung Transplantation) compared with those who did have not have rejection episodes. In a second retrospective study with 31 patients, we identified 7 IgM reactivities that were higher in heart transplant recipients who developed antibody-mediated rejection (AMR) compared with control recipients, and in time course studies, these reactivities appeared prior to overt graft dysfunction. In conclusion, we demonstrated that the autoantibody microarray technique outperforms traditional ELISAs as it uses less patient sample, has increased sensitivity, and can detect autoantibodies in a multiplex fashion. Furthermore, our results suggest that this autoantibody array technology may help to identify patients at risk of rejection following heart transplantation and identify heart transplant recipients with AMR.

  12. Generation of Antigen Microarrays to Screen for Autoantibodies in Heart Failure and Heart Transplantation

    PubMed Central

    Chruscinski, Andrzej; Huang, Flora Y. Y.; Nguyen, Albert; Lioe, Jocelyn; Tumiati, Laura C.; Kozuszko, Stella; Tinckam, Kathryn J.; Rao, Vivek; Dunn, Shannon E.; Persinger, Michael A.; Levy, Gary A.; Ross, Heather J.

    2016-01-01

    Autoantibodies directed against endogenous proteins including contractile proteins and endothelial antigens are frequently detected in patients with heart failure and after heart transplantation. There is evidence that these autoantibodies contribute to cardiac dysfunction and correlate with clinical outcomes. Currently, autoantibodies are detected in patient sera using individual ELISA assays (one for each antigen). Thus, screening for many individual autoantibodies is laborious and consumes a large amount of patient sample. To better capture the broad-scale antibody reactivities that occur in heart failure and post-transplant, we developed a custom antigen microarray technique that can simultaneously measure IgM and IgG reactivities against 64 unique antigens using just five microliters of patient serum. We first demonstrated that our antigen microarray technique displayed enhanced sensitivity to detect autoantibodies compared to the traditional ELISA method. We then piloted this technique using two sets of samples that were obtained at our institution. In the first retrospective study, we profiled pre-transplant sera from 24 heart failure patients who subsequently received heart transplants. We identified 8 antibody reactivities that were higher in patients who developed cellular rejection (2 or more episodes of grade 2R rejection in first year after transplant as defined by revised criteria from the International Society for Heart and Lung Transplantation) compared with those who did have not have rejection episodes. In a second retrospective study with 31 patients, we identified 7 IgM reactivities that were higher in heart transplant recipients who developed antibody-mediated rejection (AMR) compared with control recipients, and in time course studies, these reactivities appeared prior to overt graft dysfunction. In conclusion, we demonstrated that the autoantibody microarray technique outperforms traditional ELISAs as it uses less patient sample, has increased sensitivity, and can detect autoantibodies in a multiplex fashion. Furthermore, our results suggest that this autoantibody array technology may help to identify patients at risk of rejection following heart transplantation and identify heart transplant recipients with AMR. PMID:26967734

  13. A High-Throughput, Precipitating Colorimetric Sandwich ELISA Microarray for Shiga Toxins

    PubMed Central

    Gehring, Andrew; He, Xiaohua; Fratamico, Pina; Lee, Joseph; Bagi, Lori; Brewster, Jeffrey; Paoli, George; He, Yiping; Xie, Yanping; Skinner, Craig; Barnett, Charlie; Harris, Douglas

    2014-01-01

    Shiga toxins 1 and 2 (Stx1 and Stx2) from Shiga toxin-producing E. coli (STEC) bacteria were simultaneously detected with a newly developed, high-throughput antibody microarray platform. The proteinaceous toxins were immobilized and sandwiched between biorecognition elements (monoclonal antibodies) and pooled horseradish peroxidase (HRP)-conjugated monoclonal antibodies. Following the reaction of HRP with the precipitating chromogenic substrate (metal enhanced 3,3-diaminobenzidine tetrahydrochloride or DAB), the formation of a colored product was quantitatively measured with an inexpensive flatbed page scanner. The colorimetric ELISA microarray was demonstrated to detect Stx1 and Stx2 at levels as low as ~4.5 ng/mL within ~2 h of total assay time with a narrow linear dynamic range of ~1–2 orders of magnitude and saturation levels well above background. Stx1 and/or Stx2 produced by various strains of STEC were also detected following the treatment of cultured cells with mitomycin C (a toxin-inducing antibiotic) and/or B-PER (a cell-disrupting, protein extraction reagent). Semi-quantitative detection of Shiga toxins was demonstrated to be sporadic among various STEC strains following incubation with mitomycin C; however, further reaction with B-PER generally resulted in the detection of or increased detection of Stx1, relative to Stx2, produced by STECs inoculated into either axenic broth culture or culture broth containing ground beef. PMID:24921195

  14. Development and application of antibody microarray for lymphocystis disease virus detection in fish.

    PubMed

    Sheng, Xiuzhen; Xu, Xiaoli; Zhan, Wenbin

    2013-05-01

    Lymphocystis disease virus (LCDV) is the causative agent of lymphocystis disease affecting marine and freshwater fish worldwide. Here an antibody microarray was developed and employed to detect LCDV in fish. Rabbit anti-LCDV serum was arrayed on agarose gel-modified slides as capture antibody, and Cy3-conjugated anti-LCDV monoclonal antibody (MAbs) was added as detection antibody. The signals were imaged with a laser chip scanner and analyzed by corresponding software. To improve the sensitivity, different substrate binders (poly-L-lysine, MPTS, aldehyde, APES and agarose gel modified slides, and commercially available amino-modified slides), markers (fluorescein isothiocyanate, Cy3, horseradish peroxidase, biotin or colloidal gold) conjugated to anti-LCDV Mabs, and storage time of the antibody were assessed. The results showed that the antibody microarrays based on agarose gel-modified slides gave a lower detection limit of 0.55μg/ml of LCDV when Cy3 and HRP conjugated anti-LCDV MAbs were used as detection antibody; and the lowest detectable LCDV protein concentration was 0.0686 μg/ml when streptavidin-biotin conjugated to anti-LCDV MAbs served as detection antibody. The developed antibody microarray proved to have a high specificity for LCDV detection and a shelf-life of more than 8 months at -20°C. Furthermore, the LCDV detection results of the microarray in fish gills or fins (n=50) presented a concordance rate of 100% with enzyme-linked immunosorbent assay (ELISA) and 98% with immunofluorescence assay technique (IFAT). These results revealed that the developed antibody microarray could serve as an effective tool for diagnostic and epidemiological studies of LCDV in fish. Copyright © 2013 Elsevier B.V. All rights reserved.

  15. Comparison of printed glycan array, suspension array and ELISA in the detection of human anti-glycan antibodies.

    PubMed

    Pochechueva, Tatiana; Jacob, Francis; Goldstein, Darlene R; Huflejt, Margaret E; Chinarev, Alexander; Caduff, Rosemarie; Fink, Daniel; Hacker, Neville; Bovin, Nicolai V; Heinzelmann-Schwarz, Viola

    2011-12-01

    Anti-glycan antibodies represent a vast and yet insufficiently investigated subpopulation of naturally occurring and adaptive antibodies in humans. Recently, a variety of glycan-based microarrays emerged, allowing high-throughput profiling of a large repertoire of antibodies. As there are no direct approaches for comparison and evaluation of multi-glycan assays we compared three glycan-based immunoassays, namely printed glycan array (PGA), fluorescent microsphere-based suspension array (SA) and ELISA for their efficacy and selectivity in profiling anti-glycan antibodies in a cohort of 48 patients with and without ovarian cancer. The ABO blood group glycan antigens were selected as well recognized ligands for sensitivity and specificity assessments. As another ligand we selected P(1), a member of the P blood group system recently identified by PGA as a potential ovarian cancer biomarker. All three glyco-immunoassays reflected the known ABO blood groups with high performance. In contrast, anti-P(1) antibody binding profiles displayed much lower concordance. Whilst anti-P(1) antibody levels between benign controls and ovarian cancer patients were significantly discriminated using PGA (p=0.004), we got only similar results using SA (p=0.03) but not for ELISA. Our findings demonstrate that whilst assays were largely positively correlated, each presents unique characteristic features and should be validated by an independent patient cohort rather than another array technique. The variety between methods presumably reflects the differences in glycan presentation and the antigen/antibody ratio, assay conditions and detection technique. This indicates that the glycan-antibody interaction of interest has to guide the assay selection. © The Author(s) 2011. This article is published with open access at Springerlink.com

  16. Recombinant blood group proteins for use in antibody screening and identification tests.

    PubMed

    Seltsam, Axel; Blasczyk, Rainer

    2009-11-01

    The present review elucidates the potentials of recombinant blood group proteins (BGPs) for red blood cell (RBC) antibody detection and identification in pretransfusion testing and the achievements in this field so far. Many BGPs have been eukaryotically and prokaryotically expressed in sufficient quantity and quality for RBC antibody testing. Recombinant BGPs can be incorporated in soluble protein reagents or solid-phase assays such as ELISA, color-coded microsphere and protein microarray chip-based techniques. Because novel recombinant protein-based assays use single antigens, a positive reaction of a serum with the recombinant protein directly indicates the presence and specificity of the target antibody. Inversely, conventional RBC-based assays use panels of human RBCs carrying a huge number of blood group antigens at the same time and require negative reactions of samples with antigen-negative cells for indirect determination of antibody specificity. Because of their capacity for single-step, direct RBC antibody determination, recombinant protein-based assays may greatly facilitate and accelerate the identification of common and rare RBC antibodies.

  17. Integrated poly(dimethysiloxane) with an intrinsic nonfouling property approaching "absolute" zero background in immunoassays.

    PubMed

    Ma, Hongwei; Wu, Yuanzi; Yang, Xiaoli; Liu, Xing; He, Jianan; Fu, Long; Wang, Jie; Xu, Hongke; Shi, Yi; Zhong, Renqian

    2010-08-01

    The key to achieve a highly sensitive and specific protein microarray assay is to prevent nonspecific protein adsorption to an "absolute" zero level because any signal amplification method will simultaneously amplify signal and noise. Here, we develop a novel solid supporting material, namely, polymer coated initiator integrated poly(dimethysiloxane) (iPDMS), which was able to achieve such "absolute" zero (i.e., below the detection limit of instrument). The implementation of this iPDMS enables practical and high-quality multiplexed enzyme-linked immunosorbent assay (ELISA) of 11 tumor markers. This iPDMS does not need any blocking steps and only require mild washing conditions. It also uses on an average 8-fold less capture antibodies compared with the mainstream nitrocellulose (NC) film. Besides saving time and materials, iPDMS achieved a limit-of-detection (LOD) as low as 19 pg mL(-1), which is sufficiently low for most current clinical diagnostic applications. We expect to see an immediate impact of this iPDMS on the realization of the great potential of protein microarray in research and practical uses such as large scale and high-throughput screening, clinical diagnosis, inspection, and quarantine.

  18. Comparative study of the diagnostic and prognostic value of antibodies against chimeric citrullinated synthetic peptides and CCP3/CCP3.1 assays.

    PubMed

    Gómara, María J; Rodríguez, Javier; Bleda, María J; Salvador, Juan P; Sanmartí, Raimon; Haro, Isabel

    2018-01-26

    The objective of the study was to compare the diagnostic yield of home-made ELISA tests based on synthetic chimeric fibrin/filaggrin citrullinated peptides (CFFCPs) with CCP3 and CCP3.1 commercial tests to detect anti-citrullinated protein/peptide antibodies (ACPAs) in rheumatoid arthritis (RA) patients. The prognostic value is also studied in a cohort of patients with early RA. Moreover, we transfer immunological assays from microtiter plates to microarray formats to allow the simultaneous analysis of several peptide sequences and reduce the volume of serum from patients. The diagnostic study includes: 100 RA patients who fulfilled the 1987 ACR criteria; 100 healthy blood donors; 35 patients with SLE according ACR criteria; 35 patients with PsA fulfilling the Wright and Moll criteria and 30 patients with HCV infection. The prognostic value study includes 50 patients with early RA with follow-up data available. All samples are from outpatients attending the Rheumatology Department of the Hospital Clinic of Barcelona. Similar sensitivity, specificity and predictive values for the diagnosis of RA of CCFCPs compared to CCP3/CCP3.1 were obtained. Although a high concordance is observed between anti-CFFCPs and anti-CCP3/CCP3.1 in the early patients that rendered Larsen radiographic progression, CFFCPs could be a better marker of radiographic outcome. Strong correlations between the microarray and ELISA results were found for individual CFFCPs peptides. The development of multiplexing techniques combining a different spectrum of markers in a single analysis, including CFFCP peptides, could allow a more detailed analysis of the autoantibodies reactivity found in the sera of patients suffering of this heterogeneous disease.

  19. A High Throughput Protein Microarray Approach to Classify HIV Monoclonal Antibodies and Variant Antigens

    PubMed Central

    Dotsey, Emmanuel Y.; Gorlani, Andrea; Ingale, Sampat; Achenbach, Chad J.; Forthal, Donald N.; Felgner, Philip L.; Gach, Johannes S.

    2015-01-01

    In recent years, high throughput discovery of human recombinant monoclonal antibodies (mAbs) has been applied to greatly advance our understanding of the specificity, and functional activity of antibodies against HIV. Thousands of antibodies have been generated and screened in functional neutralization assays, and antibodies associated with cross-strain neutralization and passive protection in primates, have been identified. To facilitate this type of discovery, a high throughput-screening tool is needed to accurately classify mAbs, and their antigen targets. In this study, we analyzed and evaluated a prototype microarray chip comprised of the HIV-1 recombinant proteins gp140, gp120, gp41, and several membrane proximal external region peptides. The protein microarray analysis of 11 HIV-1 envelope-specific mAbs revealed diverse binding affinities and specificities across clades. Half maximal effective concentrations, generated by our chip analysis, correlated significantly (P<0.0001) with concentrations from ELISA binding measurements. Polyclonal immune responses in plasma samples from HIV-1 infected subjects exhibited different binding patterns, and reactivity against printed proteins. Examining the totality of the specificity of the humoral response in this way reveals the exquisite diversity, and specificity of the humoral response to HIV. PMID:25938510

  20. Diagnosis of Zika Virus Infection by Peptide Array and Enzyme-Linked Immunosorbent Assay

    PubMed Central

    Caciula, Adrian; Price, Adam; Thakkar, Riddhi; Ng, James; Chauhan, Lokendra V.; Jain, Komal; Che, Xiaoyu; Espinosa, Diego A.; Montoya Cruz, Magelda; Balmaseda, Angel; Sullivan, Eric H.; Patel, Jigar J.; Jarman, Richard G.; Rakeman, Jennifer L.; Egan, Christina T.; Reusken, Chantal B. E. M.; Koopmans, Marion P. G.; Harris, Eva; Tokarz, Rafal; Briese, Thomas

    2018-01-01

    ABSTRACT Zika virus (ZIKV) is implicated in fetal stillbirth, microcephaly, intracranial calcifications, and ocular anomalies following vertical transmission from infected mothers. In adults, infection may trigger autoimmune inflammatory polyneuropathy. Transmission most commonly follows the bite of infected Aedes mosquitoes but may also occur through sexual intercourse or receipt of blood products. Definitive diagnosis through detection of viral RNA is possible in serum or plasma within 10 days of disease onset, in whole blood within 3 weeks of onset, and in semen for up to 3 months. Serological diagnosis is nonetheless critical because few patients have access to molecular diagnostics during the acute phase of infection and infection may be associated with only mild or inapparent disease that does not prompt molecular testing. Serological diagnosis is confounded by cross-reactivity of immune sera with other flaviviruses endemic in the areas where ZIKV has recently emerged. Accordingly, we built a high-density microarray comprising nonredundant 12-mer peptides that tile, with one-residue overlap, the proteomes of Zika, dengue, yellow fever, West Nile, Ilheus, Oropouche, and chikungunya viruses. Serological analysis enabled discovery of a ZIKV NS2B 20-residue peptide that had high sensitivity (96.0%) and specificity (95.9%) versus natural infection with or vaccination against dengue, chikungunya, yellow fever, West Nile, tick-borne encephalitis, or Japanese encephalitis virus in a microarray assay and an enzyme-linked immunosorbent assay (ELISA) of early-convalescent-phase sera (2 to 3 weeks after onset of symptomatic infection). PMID:29511073

  1. Quantitation of sperm bindable IgA and IgG in seminal fluid.

    PubMed

    Howe, S E; Lynch, D M

    1986-05-01

    Seminal fluid and serum from 95 infertile males were assayed for sperm bindable immunoglobulins using an indirect ELISA with whole target sperm. The ELISA method was compared to seminal fluid and serum immobilization and agglutination assays (functional assays). In this infertile group, the ELISA assay was positive in 22% of seminal fluids (greater than 1.2 fg IgA/sperm and greater than 0.3 fg IgG/sperm). The seminal fluid antibodies were IgA and had an accompanying elevated IgG component in 78% of patients. There was a 96% correlation between negative seminal fluid functional assays and negative ELISA, and a 95% correlation between positive seminal fluid functional assays and positive ELISA. Positive serum sperm antibody tests were found in 71% of the infertile males with positive seminal fluid sperm antibodies, but 29% of the infertile males with strongly positive IgA seminal fluid sperm antibodies showed normal levels of serum sperm antibodies by either ELISA or functional assays. The ELISA method gives reproducible quantitation of sperm antibodies in seminal fluid and correlates well with accepted functional assays. Comparisons with serum sperm antibody assays suggests that seminal fluid sperm antibody analysis complements the serum analysis of sperm antibodies.

  2. Evaluation of diagnostic assays for the serological detection of Actinobacillus pleuropneumoniae on samples of known or unknown exposure.

    PubMed

    Opriessnig, Tanja; Hemann, Michelle; Johnson, John K; Heinen, Sheila; Giménez-Lirola, Luis G; O'Neill, Kevin C; Hoang, Hai; Yoon, Kyoung-Jin; Gottschalk, Marcelo; Halbur, Patrick G

    2013-01-01

    Accurate diagnosis of exposure to Actinobacillus pleuropneumoniae is important for maintaining negative farms. In the present study, the ability of a dual-plate complement fixation (CF) assay and 3 commercially available enzyme-linked immunosorbent assays (ELISAs; quad-plate ELISA-1, single-plate ELISA-2, and single-plate ELISA-3) in detecting serological evidence of A. pleuropneumoniae exposure was compared using serum samples of experimentally infected or vaccinated pigs, or field samples from the United States. Forty-two pigs were divided into groups of 2 pigs and were inoculated with 1 of 15 A. pleuropneumoniae strains representing all known serovars of A. pleuropneumoniae, or with Actinobacillus suis, or were vaccinated with a bacterin containing A. pleuropneumoniae serovar 1, 3, 5, or 7. Serum samples collected at the day of inoculation or vaccination and 7, 14, 21, and 28 days later were used to compare the assays. On samples from experimentally infected pigs, the dual-plate CF assay, quad-plate ELISA-1, single-plate ELISA-2, and single-plate ELISA-3 had sensitivities of 0.46, 0.74, 0.13, and 0.13 and specificities of 0.90, 1.0, 1.0, and 1.0, respectively. Vaccinated pigs were identified only by the dual-plate CF assay and the quad-plate ELISA-1. In addition, 90 serum samples with unknown A. pleuropneumoniae exposure collected under field conditions were tested with all assays. The agreement of the 4 assays on field samples was slight to fair. While several assays are available for demonstration of A. pleuropneumoniae exposure, differences in assay targets complicate test choices. Decisions on which assay or combination of assays to use depend on the specific reasons for running the assays.

  3. Agreement between commercial assays for haptoglobin and serum amyloid A in goats.

    PubMed

    Czopowicz, Michał; Szaluś-Jordanow, Olga; Mickiewicz, Marcin; Moroz, Agata; Witkowski, Lucjan; Markowska-Daniel, Iwona; Reczyńska, Daria; Bagnicka, Emilia; Kaba, Jarosław

    2017-10-02

    Haptoglobin (Hp) and serum amyloid A (SAA) are considered as the major acute phase proteins (APPs) in goats. These APPs have been investigated in several studies during the last decade. In most studies, a colorimetric assay for Hp and a solid phase sandwich ELISA for SAA have been used for quantification. In 2015, reference intervals for APPs were determined using a new type of assay, the competitive ELISA (cELISA). Results obtained by the cELISA differed significantly from results obtained by previously used assays. The present study aimed to assess the agreement between so far used assays and cELISAs. Sera of 152 female dairy goats of two Polish national breeds were analysed. The concentration of Hp was determined using a colorimetric assay (Hp-CA) and the cELISA (Hp-cELISA), while a solid phase sandwich ELISA (SAA-sELISA) and the cELISA (SAA-cELISA) were used to measure SAA. Agreement between test results was assessed by preparing Bland-Altman plots, and analyzing 95% limits of agreement (LoA). Finally, the assays for Hp and SAA were compared using 147 and 138 serum samples, respectively, as 5 and 14 paired measurements, respectively, were excluded from agreement analyses to avoid extrapolation of Hp and SAA concentration. Measurements obtained by the Hp-CA and Hp-cELISA showed weak positive correlation (r = 0.24, P = 0.003). Limits of agreement (LoA) ranged from + 1.6 (95% CI 1.4 to 1.8) g/L to - 1.5 (95% CI - 1.7 to - 1.3) g/L. Measurements yielded by the SAA-sELISA and SAA-cELISA did not correlate (r = - 0.01, P = 0.855). LoA ranged from + 14.5 mg/L (95% CI 12.9 to 16.1) to - 8.5 mg/L (95% CI - 10.1 to - 6.9). Agreement between the two types of commercial assays for determination of Hp and SAA concentrations in goats is poor and cELISAs tend to underrate both Hp and SAA concentrations.

  4. ELISA-LOC: lab-on-a-chip for enzyme-linked immunodetection.

    PubMed

    Sun, Steven; Yang, Minghui; Kostov, Yordan; Rasooly, Avraham

    2010-08-21

    A miniature 96 sample ELISA-lab-on-a-chip (ELISA-LOC) was designed, fabricated, and tested for immunological detection of Staphylococcal Enterotoxin B (SEB). The chip integrates a simple microfluidics system into a miniature ninety-six sample plate, allowing the user to carry out an immunological assay without a laboratory. Assay reagents are delivered into the assay plate without the need for separate devices commonly used in immunoassays. The ELISA-LOC was constructed using Laminated Object Manufacturing (LOM) technology to assemble six layers with an acrylic (poly(methyl methacrylate) (PMMA)) core and five polycarbonate layers micromachined by a CO(2) laser. The ELISA-LOC has three main functional elements: reagent loading fluidics, assay and detection wells, and reagent removal fluidics, a simple "surface tension" valve used to control the flow. To enhance assay sensitivity and to perform the assay without a lab, ELISA-LOC detection combines several biosensing elements: (1) carbon nanotube (CNT) technology to enhance primary antibody immobilization, (2) sensitive ECL (electrochemiluminescence) detection, and (3) a charge-coupled device (CCD) detector for measuring the light signal generated by ECL. Using a sandwich ELISA assay, the system detected SEB at concentrations as low as 0.1 ng ml(-1), which is similar to the reported sensitivity of conventional ELISA. The fluidics system can be operated by a syringe and does not require power for operation. This simple point-of-care (POC) system is useful for carrying out various immunological assays and other complex medical assays without a laboratory.

  5. Detection of liver kidney microsomal type 1 antibody using molecularly based immunoassays

    PubMed Central

    Kerkar, N; Ma, Y; Davies, E T; Cheeseman, P; Mieli-Vergani, G; Vergani, D

    2002-01-01

    Aims: To assess the diagnostic value of two commercial molecularly based immunoassays detecting liver kidney microsomal type 1 antibody (LKM1). Methods: The performance of Varelisa and LKM1 enzyme linked immunosorbent assay (ELISA) was compared with immunofluorescence, and two validated research techniques—an in house ELISA and a radioligand assay measuring antibodies to P4502D6. Thirty serum samples from three patients with autoimmune hepatitis type 2 covering immunofluorescence titres of 1/10 to 1/10 240 and 55 LKM1 negative controls were tested. Results: All 30 sera that were LKM1 positive by immunofluorescence were positive by the in house ELISA, the radioligand assay, and LKM1-ELISA, and 29 were also positive by Varelisa. None of the 55 sera negative for LKM1 by immunofluorescence was positive by the in house ELISA and radioligand assay, but one was positive by Varelisa and 14 were positive using the LKM1-ELISA. Agreement between immunofluorescence, the in house ELISA, the radioligand assay, and Varelisa was high (κ > 0.8), and agreement between immunofluorescence and LKM1-ELISA was moderate (κ = 0.63). Conclusion: The assay kit marketed as Varelisa allows accurate detection of LKM1. PMID:12461054

  6. Detection of liver kidney microsomal type 1 antibody using molecularly based immunoassays.

    PubMed

    Kerkar, N; Ma, Y; Davies, E T; Cheeseman, P; Mieli-Vergani, G; Vergani, D

    2002-12-01

    To assess the diagnostic value of two commercial molecularly based immunoassays detecting liver kidney microsomal type 1 antibody (LKM1). The performance of Varelisa and LKM1 enzyme linked immunosorbent assay (ELISA) was compared with immunofluorescence, and two validated research techniques-an in house ELISA and a radioligand assay measuring antibodies to P4502D6. Thirty serum samples from three patients with autoimmune hepatitis type 2 covering immunofluorescence titres of 1/10 to 1/10 240 and 55 LKM1 negative controls were tested. All 30 sera that were LKM1 positive by immunofluorescence were positive by the in house ELISA, the radioligand assay, and LKM1-ELISA, and 29 were also positive by Varelisa. None of the 55 sera negative for LKM1 by immunofluorescence was positive by the in house ELISA and radioligand assay, but one was positive by Varelisa and 14 were positive using the LKM1-ELISA. Agreement between immunofluorescence, the in house ELISA, the radioligand assay, and Varelisa was high (kappa > 0.8), and agreement between immunofluorescence and LKM1-ELISA was moderate (kappa = 0.63). The assay kit marketed as Varelisa allows accurate detection of LKM1.

  7. Isolation of RNA From Peripheral Blood Cells: A Validation Study for Molecular Diagnostics by Microarray and Kinetic RT-PCR Assays - Application in Aerospace Medicine

    DTIC Science & Technology

    2004-01-01

    of RNA From Peripheral Blood Cells: A Validation Study for Molecular Diagnostics by Microarray and Kinetic RT-PCR Assays  Application in...VALIDATION STUDY FOR MOLECULAR DIAGNOSTICS BY MICROARRAY AND KINETIC RT-PCR ASSAYS  APPLICATION IN AEROSPACE MEDICINE INTRODUCTION Extraction of cellular

  8. Immunoglobulin M (IgM)-Glycoinositolphospholipid Enzyme-Linked Immunosorbent Assay: an Immunoenzymatic Assay for Discrimination between Patients with Acute Toxoplasmosis and Those with Persistent Parasite-Specific IgM Antibodies

    PubMed Central

    Giraldo, Mónica; Portela, Ricardo W. D.; Snege, Mirian; Leser, Paulo G.; Camargo, Mário E.; Mineo, José Roberto; Gazzinelli, Ricardo T.

    2002-01-01

    In the present study we developed an enzyme-linked immunosorbent assay (ELISA) to measure immunoglobulin M (IgM) specific for glycoinositolphospholipids (GIPL) derived from tachyzoite membrane (IgM-GIPL ELISA). The sensitivity and specificity of the assay were compared with those of commercially available Toxoplasma-specific IgM serological tests, namely, immunofluorescence assay (IFA) with fixed tachyzoites and capture ELISA employing tachyzoite extracts. Our results show that all patients with acute toxoplasmosis, as determined by clinical data and conventional serological tests, were also positive by the IgM-GIPL ELISA. Interestingly, many patients that were classified as indeterminate, who had IgG with high avidity but positive results in the IgM-specific IFA and capture ELISA, were negative by the IgM-GIPL ELISA. Finally, we tested the sera from patients with rheumatoid arthritis and various parasitic infections and found no evidence of false positives in the IgM-GIPL ELISA. PMID:11923364

  9. 9 CFR 145.14 - Testing.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... microagglutination test, the enzyme-linked immunosorbent assay test (ELISA), or the rapid serum test for all poultry... react on rapid serum test or enzyme-labeled immunosorbent assay test (ELISA), or blood from birds that... inhibition (HI) test, the microhemagglutination inhibition test, the enzyme-linked immunosorbent assay (ELISA...

  10. Serological confirmatory testing of alveolar and cystic echinococcosis in clinical practice: results of a comparative study with commercialized and in-house assays.

    PubMed

    Reiter-Owona, Ingrid; Grüner, Beate; Frosch, Matthias; Hoerauf, Achim; Kern, Peter; Tappe, Dennis

    2009-01-01

    Sera of 50 patients with either cystic (CE) or alveolar echinococcosis (AE) in different clinical stages were examined for the presence of anti-Echinococcus-antibodies. Antibody-screening was performed with ELISA, IHA and IFAT, and confirmatory testing was done by the commercialized E. multilocularis-specific Em2plus-ELISA versus an in-house E. multilocularis-specific Em10-ELISA. Sera with discrepant confirmatory results were subjected to a commercial Echinococcus IgG Western blot (WB). In sera from patients with CE, the Em2plus-ELISA showed cross-reactions in 23.5%, whereas the Em10-ELISA did not exhibit any cross-reactivity. Cross-reactivity paralleled active infection with high antibody titers in the screening assays. In sera from patients with AE, confirmation by both ELISAs was achieved in 57.6%, mostly in patients with an advanced stage of the disease and high antibody titers in the screening assays. False-negative reactions of both ELISAs occurred in 30.3%, mostly in patients who had low antibody levels in the screening tests. The Em2plus-ELISA exhibited fewer false-negative reactions than the Em10-ELISA. The WB confirmed the positive results of either assay and was the assay with the highest reliability at different stages of CE and AE, followed by the Em2plus-ELISA for AE. High antibody titers in the screening assays will favour the detection of species-specific antibodies in either form.

  11. 77 FR 11137 - Government-Owned Inventions; Availability for Licensing

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-24

    ... nonspecific, and the diagnosis is frequently difficult and delayed. The inventors established a rapid ELISA assay to evaluate biomarker levels in serum. The ELISA assay tests a novel combination of two biomarkers...-invasive ELISA serum assay. Potential for high sensitivity. Cost effective. Development Stage: Pilot. Early...

  12. Fasciola hepatica saposin-like-2 protein based ELISA for the serodiagnosis of chronic human fascioliasis

    PubMed Central

    Figueroa-Santiago, Olgary; Delgado, Bonnibel; Espino, Ana M.

    2011-01-01

    An indirect enzyme-linked immunosorbent assay (ELISA) was developed and evaluated for its diagnostic ability to detect human IgG antibodies against Fasciola hepatica saposin-like protein-2. The assay was compared with an indirect ELISA with excretory-secretory products (FhES) from adult F. hepatica. In an analysis of the sera of 37 patients infected with F. hepatica, 40 patients with other parasitic infections, and 50 healthy controls, the sensitivity of both ELISA assays was 100%. However, the FhSAP2-based ELISA was more specific (95.6%) than the FhES-ELISA (91.9%). These results demonstrated that FhSAP2 can be used in the serodiagnosis of chronic human fascioliasis with additional advantage that is relative cheap and easy to produce. Studies are in progress to evaluate this FhSAP2-ELISA assay in a large-scale prevalence surveys in endemic areas. PMID:21683266

  13. 9 CFR 145.14 - Testing.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... immunosorbent assay test (ELISA), or the rapid serum test for all poultry; and the stained antigen, rapid whole... test or enzyme-labeled immunosorbent assay test (ELISA), or blood from birds that react on the stained... enzyme-linked immunosorbent assay (ELISA) test,3 a polymerase chain reaction (PCR)-based test, or a...

  14. 76 FR 4920 - Government-Owned Inventions; Availability for Licensing

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-01-27

    ... appear to be distinct from each other. Available for licensing is a Plk1 ELISA assay using peptide... binding property, an easy and reliable ELISA assay has been developed to quantify Plk1 expression levels... sequence. ELISA assay to quantify Plk1 expression and kinase activity. Advantages: Rapid, highly sensitive...

  15. 76 FR 15791 - National Poultry Improvement Plan and Auxiliary Provisions

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-22

    ... microhemagglutination inhibition test, the enzyme-linked immunosorbent assay (ELISA) test,\\3\\ a polymerase chain [[Page... samplings and/or culture of reactors. \\3\\ Procedures for the enzyme-linked immunosorbent assay (ELISA) test... Immunosorbent Assay (ELISA),'' Proceedings, 30th Western Poultry Disease Conference, pp. 63-66, March 1981...

  16. 9 CFR 145.14 - Testing.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... immunosorbent assay test (ELISA), or the rapid serum test for all poultry; and the stained antigen, rapid whole... test or enzyme-labeled immunosorbent assay test (ELISA), or blood from birds that react on the stained... enzyme-linked immunosorbent assay (ELISA) test,3 a polymerase chain reaction (PCR)-based test, or a...

  17. 9 CFR 145.14 - Testing.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... immunosorbent assay test (ELISA), or the rapid serum test for all poultry; and the stained antigen, rapid whole... test or enzyme-labeled immunosorbent assay test (ELISA), or blood from birds that react on the stained... enzyme-linked immunosorbent assay (ELISA) test,3 a polymerase chain reaction (PCR)-based test, or a...

  18. A novel microfluidic microplate as the next generation assay platform for enzyme linked immunoassays (ELISA).

    PubMed

    Kai, Junhai; Puntambekar, Aniruddha; Santiago, Nelson; Lee, Se Hwan; Sehy, David W; Moore, Victor; Han, Jungyoup; Ahn, Chong H

    2012-11-07

    In this work we introduce a novel microfluidic enzyme linked immunoassays (ELISA) microplate as the next generation assay platform for unparalleled assay performances. A combination of microfluidic technology with standard SBS-configured 96-well microplate architecture, in the form of microfluidic microplate technology, allows for the improvement of ELISA workflows, conservation of samples and reagents, improved reaction kinetics, and the ability to improve the sensitivity of the assay by multiple analyte loading. This paper presents the design and characterization of the microfluidic microplate, and its application in ELISA.

  19. Evaluation of a Rapid Fecal PCR Test for Detection of Mycobacterium avium subsp. paratuberculosis in Dairy Cattle▿

    PubMed Central

    Wells, Scott J.; Collins, Michael T.; Faaberg, Kay S.; Wees, Carrie; Tavornpanich, Saraya; Petrini, Kristine R.; Collins, James E.; Cernicchiaro, Natalia; Whitlock, Robert H.

    2006-01-01

    A high-throughput TaqMan PCR assay for detection of bovine paratuberculosis was evaluated by using fecal samples from 1,808 dairy cattle in seven naturally infected herds and 347 dairy cattle in seven herds considered free of paratuberculosis. Fecal, blood, and milk samples were submitted to laboratories where the PCR-based assay, three different fecal culture procedures for Mycobacterium avium subsp. paratuberculosis (centrifugation, sedimentation, and the BACTEC filter concentration method), two serologic enzyme-linked immunosorbent assays (ELISAs), and one milk ELISA were performed. Results from testing of dairy cattle in herds free of M. avium subsp. paratuberculosis showed that the PCR assay's specificity was 99.7%. Twenty-three percent of the dairy cows that were fecal culture positive by at least one of the three methods were positive by the PCR assay. By Bayesian non-“gold standard” analysis methods, the TaqMan PCR assay had a higher specificity than the serum ELISAs (99.3%; 95% confidence interval [CI] = 98.6 to 99.7%) and a test sensitivity similar to that of the serum ELISAs (29%; 95% CI = 24 to 35%). By classical methods, the estimated relative sensitivity of the fecal PCR assay was 4% for light and moderate fecal shedders (compared to 12 to 13% for the ELISAs) and 76% for heavy fecal shedders (compared to 67% for the milk ELISA). The PCR assay has higher sensitivity for detection of heavy fecal shedders than the evaluated milk ELISA but lower sensitivity than a serum or milk ELISA for detection of light and moderate fecal shedders. This assay can be used as a quick test for detection of cattle with heavy fecal shedding, those cattle with the highest risk of transmitting infection to susceptible cattle. PMID:16928884

  20. Kinetic-dependent enzyme-linked immunosorbent assay for detection of antibodies to Legionella pneumophila.

    PubMed Central

    Sampson, J S; Wilkinson, H W; Tsang, V C; Brake, B J

    1983-01-01

    A semiautomated, kinetic-dependent, enzyme-linked immunosorbent assay (K-ELISA) was adapted to detect serum antibodies to Legionella pneumophila. In a comparative study, 158 human serum samples (79 pairs) were tested by K-ELISA and the standard indirect immunofluorescence assay for determination of antibody levels to L. pneumophila serogroup 1. K-ELISA determinations were made by using a serogroup-specific antigen or a preparation (unfractionated antigen) which contained both common antigen and serogroup-specific reactivity. There was good correlation between the immunofluorescence assay and the K-ELISA by using either antigen, although greater correlation was achieved with the unfractionated antigen (coefficients of correlation, 0.894 with unfractionated antigen and 0.841 with serogroup-specific antigen). These results indicate that the K-ELISA is a reliable alternative to the immunofluorescence assay for serologically diagnosing legionellosis. PMID:6361052

  1. Kinetic-dependent enzyme-linked immunosorbent assay for detection of antibodies to Legionella pneumophila.

    PubMed

    Sampson, J S; Wilkinson, H W; Tsang, V C; Brake, B J

    1983-12-01

    A semiautomated, kinetic-dependent, enzyme-linked immunosorbent assay (K-ELISA) was adapted to detect serum antibodies to Legionella pneumophila. In a comparative study, 158 human serum samples (79 pairs) were tested by K-ELISA and the standard indirect immunofluorescence assay for determination of antibody levels to L. pneumophila serogroup 1. K-ELISA determinations were made by using a serogroup-specific antigen or a preparation (unfractionated antigen) which contained both common antigen and serogroup-specific reactivity. There was good correlation between the immunofluorescence assay and the K-ELISA by using either antigen, although greater correlation was achieved with the unfractionated antigen (coefficients of correlation, 0.894 with unfractionated antigen and 0.841 with serogroup-specific antigen). These results indicate that the K-ELISA is a reliable alternative to the immunofluorescence assay for serologically diagnosing legionellosis.

  2. An Automated Microfluidic Assay for Photonic Crystal Enhanced Detection and Analysis of an Antiviral Antibody Cancer Biomarker in Serum

    DOE PAGES

    Race, Caitlin M.; Kwon, Lydia E.; Foreman, Myles T.; ...

    2017-11-24

    Here, we report on the implementation of an automated platform for detecting the presence of an antibody biomarker for human papillomavirus-associated oropharyngeal cancer from a single droplet of serum, in which a nanostructured photonic crystal surface is used to amplify the output of a fluorescence-linked immunosorbent assay. The platform is comprised of a microfluidic cartridge with integrated photonic crystal chips that interfaces with an assay instrument that automates the introduction of reagents, wash steps, and surface drying. Upon assay completion, the cartridge interfaces with a custom laser-scanning instrument that couples light into the photonic crystal at the optimal resonance conditionmore » for fluorescence enhancement. The instrument is used to measure the fluorescence intensity values of microarray spots corresponding to the biomarkers of interest, in addition to several experimental controls that verify correct functioning of the assay protocol. In this work, we report both dose-response characterization of the system using anti-E7 antibody introduced at known concentrations into serum and characterization of a set of clinical samples from which results were compared with a conventional enzyme-linked immunosorbent assay (ELISA) performed in microplate format. Finally, the demonstrated capability represents a simple, rapid, automated, and high-sensitivity method for multiplexed detection of protein biomarkers from a low-volume test sample.« less

  3. An Automated Microfluidic Assay for Photonic Crystal Enhanced Detection and Analysis of an Antiviral Antibody Cancer Biomarker in Serum

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Race, Caitlin M.; Kwon, Lydia E.; Foreman, Myles T.

    Here, we report on the implementation of an automated platform for detecting the presence of an antibody biomarker for human papillomavirus-associated oropharyngeal cancer from a single droplet of serum, in which a nanostructured photonic crystal surface is used to amplify the output of a fluorescence-linked immunosorbent assay. The platform is comprised of a microfluidic cartridge with integrated photonic crystal chips that interfaces with an assay instrument that automates the introduction of reagents, wash steps, and surface drying. Upon assay completion, the cartridge interfaces with a custom laser-scanning instrument that couples light into the photonic crystal at the optimal resonance conditionmore » for fluorescence enhancement. The instrument is used to measure the fluorescence intensity values of microarray spots corresponding to the biomarkers of interest, in addition to several experimental controls that verify correct functioning of the assay protocol. In this work, we report both dose-response characterization of the system using anti-E7 antibody introduced at known concentrations into serum and characterization of a set of clinical samples from which results were compared with a conventional enzyme-linked immunosorbent assay (ELISA) performed in microplate format. Finally, the demonstrated capability represents a simple, rapid, automated, and high-sensitivity method for multiplexed detection of protein biomarkers from a low-volume test sample.« less

  4. Development of a sensitive enzyme-linked immunosorbent assay for the measurement of biologically active etanercept in patients with ankylosing spondylitis.

    PubMed

    Wang, Lei; Wang, Xiaoxia; Li, Ying; Cheng, Zeneng

    2016-01-01

    Etanercept is the first tumor necrosis factor inhibitor to be approved for rheumatic disease treatment. Its in vivo concentration is usually detected with commercial enzyme-linked immunosorbent assay (ELISA) kits; specifically, previous researchers have mostly used double-antibody sandwich ELISA technology. Double-antibody sandwich ELISA is employed to detect the total etanercept rather than biologically active etanercept, which is more relevant in terms of therapeutic drug monitoring. In this work, a sensitive ELISA that employed its antigen TNF-α to capture biologically active etanercept for concentration detection was established and validated for etanercept pharmacokinetic (PK) study in patients with ankylosing spondylitis (AS). The proposed assay was demonstrated to be precise and accurate over the linear range of 12.5-400pg/mL. The intra- and inter-assay relative standard deviation ranged from 3.9 to 12.2% and 6.2 to 11.1%, respectively, and recovery varied between 90.1 and 99.7%, confirming the assay's reliability. The effectiveness and accuracy of the assay was also validated according to quality samples containing etanercept with different TNF-α concentrations, and with plasma samples from patients with AS. To complete the study, both the proposed assay and double-antibody sandwich ELISA were applied to the PK study of etanercept in patients and compared. The multiple-dose results of both analytical methods were consistent, while the drug exposure of the first dose as-detected by the proposed assay was lower than that detected by double-antibody sandwich ELISA. In conclusion, the proposed ELISA was shown to provide more accurate concentration data for therapeutic drug monitoring in comparison to commercial ELISA kits. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. Detection of Francisella tularensis-Specific Antibodies in Patients with Tularemia by a Novel Competitive Enzyme-Linked Immunosorbent Assay

    PubMed Central

    Sharma, Neekun; Hotta, Akitoyo; Yamamoto, Yoshie; Fujita, Osamu; Uda, Akihiko; Morikawa, Shigeru; Yamada, Akio

    2013-01-01

    A novel competitive enzyme-linked immunosorbent assay (cELISA) was developed and evaluated for detection of antibodies against Francisella tularensis in humans. The assay is based on the ability of serum antibodies to inhibit the binding of monoclonal antibodies (MAbs) directed against F. tularensis lipopolysaccharide antigens. The assay was evaluated using serum samples of tularemia patients, inactivated F. tularensis-immunized rabbits, and F. tularensis-infected mice. Antibodies against F. tularensis were successfully detected in serum samples of tularemia patients as well as the immunized and infected animals. The cELISA method was compared to indirect ELISA (iELISA) and the commonly used microagglutination test (MA) using serum samples of 19 tularemia patients and 50 healthy individuals. The sensitivity and specificity of cELISA were 93.9 and 96.1%, respectively, in comparison to the iELISA. MA was less sensitive than cELISA with a sensitivity and specificity of only 81.8 and 98.0%, respectively. A high degree of correlation (R2 = 0.8226) was observed between cELISA and iELISA results. The novel cELISA developed in this study appears to be highly sensitive and specific for serodiagnosis of human tularemia. The potential of the MAb-based cELISA to be used in both human and animal samples emphasizes its usefulness for serological survey of tularemia among multiple animal species. PMID:23114700

  6. Porous Silicon Antibody Microarrays for Quantitative Analysis: Measurement of Free and Total PSA in Clinical Plasma Samples

    PubMed Central

    Tojo, Axel; Malm, Johan; Marko-Varga, György; Lilja, Hans; Laurell, Thomas

    2014-01-01

    The antibody microarrays have become widespread, but their use for quantitative analyses in clinical samples has not yet been established. We investigated an immunoassay based on nanoporous silicon antibody microarrays for quantification of total prostate-specific-antigen (PSA) in 80 clinical plasma samples, and provide quantitative data from a duplex microarray assay that simultaneously quantifies free and total PSA in plasma. To further develop the assay the porous silicon chips was placed into a standard 96-well microtiter plate for higher throughput analysis. The samples analyzed by this quantitative microarray were 80 plasma samples obtained from men undergoing clinical PSA testing (dynamic range: 0.14-44ng/ml, LOD: 0.14ng/ml). The second dataset, measuring free PSA (dynamic range: 0.40-74.9ng/ml, LOD: 0.47ng/ml) and total PSA (dynamic range: 0.87-295ng/ml, LOD: 0.76ng/ml), was also obtained from the clinical routine. The reference for the quantification was a commercially available assay, the ProStatus PSA Free/Total DELFIA. In an analysis of 80 plasma samples the microarray platform performs well across the range of total PSA levels. This assay might have the potential to substitute for the large-scale microtiter plate format in diagnostic applications. The duplex assay paves the way for a future quantitative multiplex assay, which analyses several prostate cancer biomarkers simultaneously. PMID:22921878

  7. A Halotyrosine Antibody that Detects Increased Protein Modifications in Asthma Patients

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jin, Hongjun; Hallstrand, Teal S.; Daly, Don S.

    Background-Airway inflammation plays an important pathophysiological role in asthma. Eosinophils produce hypobromite and bromotyrosine while neutrophils produce hypochlorite and chlorotyrosine. Objective-To evaluate halotyrosine modifications of individual airway proteins as a marker of inflammation in asthma using an antibody-based assay. Methods-We developed a novel monoclonal antibody (BTK-94C) that binds halogenated tyrosine residues, and used this antibody in a custom enzyme-linked immunosorbent assay (ELISA) microarray platform to examine halotyrosine levels in 23 proteins in three independent sets of sputum samples (52 samples total). Results-In 15 subjects with either no asthma, or with asthma characterized by high or low sputum eosinophil counts, wemore » found associations between increased halotyrosine levels of at least three proteins and severity of airway hyperresponsiveness (AHR). Treatment with mepolizumab in 17 patients with sputum eosinophilia markedly reduced the sputum eosinophilia and significantly reduced halotyrosine levels in one sputum protein. Further analysis of 10 subjects with neutrophilic asthma and 10 health controls demonstrated a broad increase in halotyrosine in the patients with airway neutrophilia. Conclusions-Significantly higher levels of halotyrosine are associated with asthma in the asthma phenotypes we examined. The halotyrosine levels correlated with indirect AHR in the form of exercise-induced bronchoconstriction. Clinical Implication-An antibody-based assay for tyrosine halogenation in specific proteins may prove useful for assessing airway inflammation in asthma. Capsule Summary-An antibody to measure protein monobrominated tyrosine and other halotyrosine modifications was developed and used to evaluate halogenation in specific proteins in the airways for the first time. Associations were found between levels of halotyrosine and exercise-induced bronchoconstriction, and eosinophil and neutrophil inflammation in sputum from asthma patients. The ELISA developed here can be easily translated into a clinical test.« less

  8. Development and Comparison of Two Assay Formats for Parallel Detection of Four Biothreat Pathogens by Using Suspension Microarrays

    PubMed Central

    Janse, Ingmar; Bok, Jasper M.; Hamidjaja, Raditijo A.; Hodemaekers, Hennie M.; van Rotterdam, Bart J.

    2012-01-01

    Microarrays provide a powerful analytical tool for the simultaneous detection of multiple pathogens. We developed diagnostic suspension microarrays for sensitive and specific detection of the biothreat pathogens Bacillus anthracis, Yersinia pestis, Francisella tularensis and Coxiella burnetii. Two assay chemistries for amplification and labeling were developed, one method using direct hybridization and the other using target-specific primer extension, combined with hybridization to universal arrays. Asymmetric PCR products for both assay chemistries were produced by using a multiplex asymmetric PCR amplifying 16 DNA signatures (16-plex). The performances of both assay chemistries were compared and their advantages and disadvantages are discussed. The developed microarrays detected multiple signature sequences and an internal control which made it possible to confidently identify the targeted pathogens and assess their virulence potential. The microarrays were highly specific and detected various strains of the targeted pathogens. Detection limits for the different pathogen signatures were similar or slightly higher compared to real-time PCR. Probit analysis showed that even a few genomic copies could be detected with 95% confidence. The microarrays detected DNA from different pathogens mixed in different ratios and from spiked or naturally contaminated samples. The assays that were developed have a potential for application in surveillance and diagnostics. PMID:22355407

  9. Development and comparison of two assay formats for parallel detection of four biothreat pathogens by using suspension microarrays.

    PubMed

    Janse, Ingmar; Bok, Jasper M; Hamidjaja, Raditijo A; Hodemaekers, Hennie M; van Rotterdam, Bart J

    2012-01-01

    Microarrays provide a powerful analytical tool for the simultaneous detection of multiple pathogens. We developed diagnostic suspension microarrays for sensitive and specific detection of the biothreat pathogens Bacillus anthracis, Yersinia pestis, Francisella tularensis and Coxiella burnetii. Two assay chemistries for amplification and labeling were developed, one method using direct hybridization and the other using target-specific primer extension, combined with hybridization to universal arrays. Asymmetric PCR products for both assay chemistries were produced by using a multiplex asymmetric PCR amplifying 16 DNA signatures (16-plex). The performances of both assay chemistries were compared and their advantages and disadvantages are discussed. The developed microarrays detected multiple signature sequences and an internal control which made it possible to confidently identify the targeted pathogens and assess their virulence potential. The microarrays were highly specific and detected various strains of the targeted pathogens. Detection limits for the different pathogen signatures were similar or slightly higher compared to real-time PCR. Probit analysis showed that even a few genomic copies could be detected with 95% confidence. The microarrays detected DNA from different pathogens mixed in different ratios and from spiked or naturally contaminated samples. The assays that were developed have a potential for application in surveillance and diagnostics.

  10. An ELISA Lab-on-a-Chip (ELISA-LOC).

    PubMed

    Rasooly, Avraham; Bruck, Hugh A; Kostov, Yordan

    2013-01-01

    Laminated object manufacturing (LOM) technology using polymer sheets is an easy and affordable method for rapid prototyping of Lab-on-a-Chip (LOC) systems. It has recently been used to fabricate a miniature 96 sample ELISA lab-on-a-chip (ELISA-LOC) by integrating the washing step directly into an ELISA plate. LOM has been shown to be capable of creating complex 3D microfluidics through the assembly of a stack of polymer sheets with features generated by laser micromachining and by bonding the sheets together with adhesive. A six layer ELISA-LOC was fabricated with an acrylic (poly(methyl methacrylate) (PMMA)) core and five polycarbonate layers micromachined by a CO(2) laser with simple microfluidic features including a miniature 96-well sample plate. Immunological assays can be carried out in several configurations (1 × 96 wells, 2 × 48 wells, or 4 × 24 wells). The system includes three main functional elements: (1) a reagent loading fluidics module, (2) an assay and detection wells plate, and (3) a reagent removal fluidics module. The ELISA-LOC system combines several biosensing elements: (1) carbon nanotube (CNT) technology to enhance primary antibody immobilization, (2) sensitive ECL (electrochemiluminescence) detection, and (3) a charge-coupled device (CCD) detector for measuring the light signal generated by ECL. Using a sandwich ELISA assay, the system detected Staphylococcal enterotoxin B (SEB) at concentrations as low as 0.1 ng/ml, a detection level similar to that reported for conventional ELISA. ELISA-LOC can be operated by a syringe and does not require power for operation. This simple point-of-care (POC) system is useful for carrying out various immunological assays and other complex medical assays without the laboratory required for conventional ELISA, and therefore may be more useful for global healthcare delivery.

  11. Molecular Diversity of Macrophages in Allergic Reaction: Comparison between the Allergenic Modes; Th1- and -Th2-Derived Immune Conditions.

    PubMed

    Bagheri, Mozhdeh; Dong, Yupeng; Ono, Masao

    2015-06-01

    Activated macrophages have been classified into classical (M1) and alternative (M2) macrophages. We aimed to establish a method to yield enough number of macrophages to analyze their molecular, biological and immunological functions. We used drugs; adjuvant albumin from chicken egg whites--Imject Alum (OVA-Alum) and OVA Complete Freund Adjuvant (OVA-CFA), to induce macrophages to M2 and M1 respectively. We analyzed the phenotype of purified macrophages induced under these immune conditions, using flow cytometry (FACS) to detect cell-surface molecules and the enzyme-linked immunosorbent assay (ELISA) was used to detect cytokines. The cDNA microarray was employed to measure changes in expression level of cell surface protein between M1 and M2 macrophages. Phenotype analysis of purified macrophages, induced under these immune conditions, showed macrophages induced by OVA-Alum was almost M2 while the proportion of M1 macrophages induced by OVA-CFA was significantly higher. The results also showed higher expression level of macrophage galactose N- acetyl-galactosamine specific lectin-2 protein (MGL1/2-PE), a known M2 macrophage marker, on the surface of Alum-induced macrophages. On the basis of these preliminary data, ELISA results revealed that after macrophage stimulation with lipopolysaccharides (LPS), the level of interleukin (IL)-10 produced by Alum- induced macrophages was higher than the level of IL-10 produced by CFA-induced macrophages. In contrast, the level of tumor necrosis factor-alpha (TNF-α) produced by CFA-induced macrophages was higher than Alum-induced macrophages. The cDNA microarray confirmed previous results and suggest immunoglobulin-like type 2 receptor alpha (Pilra) as a new marker for M1, macrophage galactose N-acetylgalactosamine-specific lectin 2 (Mgl2) as M2 macrophages marker.

  12. A comparison of the sensitivity, specificity, and molecular weight accuracy of three different commercially available Hyaluronan ELISA-like assays.

    PubMed

    Haserodt, Sarah; Aytekin, Metin; Dweik, Raed A

    2011-02-01

    Hyaluronan (HA) is a glycosaminoglycan found in the extracellular matrix and ranges from several thousand to millions of daltons in size. HA has importance in various pathological conditions and is known to be elevated in several diseases. Three commonly used, commercially available HA enzyme-linked immunosorbent assay (ELISA)-like assays (from Corgenix, Echelon and R&D) were compared on the basis of accuracy, sample variability and ability to measure a range of HA sizes. The Corgenix HA ELISA-like assay displayed the lowest intra-assay variability [coefficient of variation (CV) = 11.7 ± 3.6%], followed by R&D (CV = 12.3 ± 4.6%) and Echelon (CV = 18.9 ± 9.2%). Interassay variability was also lowest for the Corgenix assay (CV = 6.0%), intermediate for the Echelon assay (9.5%) and highest for the R&D assay (CV = 34.1%). The high interassay variability seen for the R&D assay may have been due to the effect of dilution, since the dilution-independent interassay variability was 15.5%. The concentration of the standard HA was overestimated by the Echelon assay by 85% and underestimated by the R&D and Corgenix assays by 34 and 32%, respectively. The Echelon HA ELISA-like assay was the most effective at measuring all sizes of HA tested (2 MDa and 132, 66 and 6.4 kDa), whereas the Corgenix and R&D assays were unable to detect 6.4 kDa HA. These findings suggest that the Echelon HA ELISA-like assay is better suited for size-sensitive HA measurements but has a relatively high variability. The Corgenix and R&D HA ELISA-like assays have low variability and high accuracy but are not suitable for detecting low-molecular-weight HA.

  13. Functionalization and Characterization of Metal Oxide Coatings of Stainless Steel and Silica Nanoparticles

    NASA Astrophysics Data System (ADS)

    Slaney, Anne Margaret

    The development of tolerogens, fabricated devices eliciting tolerance toward incompatible donor ABO antigens in implant patients, is the ultimate goal of this project. This would permit ABO incompatible organ transplants, increase the donor pool for patients, increase efficiency in the use of available organs, reduce waitlist times and reduce mortality rates of patients. Stainless steel stents and silica nanoparticles were chosen as platforms for the stationary and circulating tolerogens. Stainless steel was coated with silica by solgel dip-coating, electrodeposition, and atomic layer deposition (ALD). The coatings were evaluated by CV, EIS, SEM, AFM, VASE, FTIR, XPS, and AES. Of the silica films, those deposited by ALD provided superior insulating, conformal, and thin coatings. These silica ALD films outperformed even titania ALD films upon stressing. Silica ALD films were subsequently functionalized with mixtures of silane derivatives of poly(ethylene glycol) (PEG), to prevent nonspecific protein binding, and monosaccharides (MS) or trisaccharide and tetrasaccharide (TS) antigens. Functionalizations were characterized by FTIR, XPS and UV-Vis following enzyme-linked lectin assays (ELLAs) or enzyme-linked immunosorbent assays (ELISAs). Effective functionalization allowing biological availability and activity even after incubation in blood plasma was confirmed. Microarray microscope slides were similarly developed with all ABO antigen subtypes, characterized by ToF-SIMS and ELISA, and proved useful in detecting antibodies in human blood samples. Silica nanoparticles, including fluorescent and magnetic varieties, in a range of sizes were prepared by sol-gel synthesis. The nanoparticles were evaluated by SEM, DLS, zeta potential measurements, fluorescence imaging, flow cytometry, two-photon excitation fluorescence correlation spectroscopy and TEM. Different dye incorporation methods were used for effective detection of NPs, and additional silica layers improved fluorophore characteristics. Functionalization of the nanoparticles with PEG and MS or TS were determined successful using three different methods as characterized by FTIR, XPS and ELLA or ELISA and UV-Vis or flow cytometry. The most cost-effective method involved functionalizing nanoparticles with amine, which was optimized using an assay. The amine-terminated nanoparticles were used to tether a PEG linker molecule for covalent binding of PnP derivatives of MSs and TSs.

  14. Detection of HIV-1 p24 at Attomole Level by Ultrasensitive ELISA with Thio-NAD Cycling

    PubMed Central

    Nakatsuma, Akira; Kaneda, Mugiho; Kodama, Hiromi; Morikawa, Mika; Watabe, Satoshi; Nakaishi, Kazunari; Yamashita, Masakane; Yoshimura, Teruki; Miura, Toshiaki; Ninomiya, Masaki; Ito, Etsuro

    2015-01-01

    To reduce the window period between HIV-1 infection and the ability to diagnose it, a fourth-generation immunoassay including the detection of HIV-1 p24 antigen has been developed. However, because the commercially available systems for this assay use special, high-cost instruments to measure, for example, chemiluminescence, it is performed only by diagnostics companies and hub hospitals. To overcome this limitation, we applied an ultrasensitive ELISA coupled with a thio-NAD cycling, which is based on a usual enzyme immunoassay without special instruments, to detect HIV-1 p24. The p24 detection limit by our ultrasensitive ELISA was 0.0065 IU/assay (i.e., ca. 10-18 moles/assay). Because HIV-1 p24 antigen is thought to be present in the virion in much greater numbers than viral RNA copies, the value of 10-18 moles of the p24/assay corresponds to ca. 103 copies of the HIV-1 RNA/assay. That is, our ultrasensitive ELISA is chasing the detection limit (102 copies/assay) obtained by PCR-based nucleic acid testing (NAT) with a margin of only one different order. Further, the detection limit by our ultrasensitive ELISA is less than that mandated for a CE-marked HIV antigen/antibody assay. An additional recovery test using blood supported the reliability of our ultrasensitive ELISA. PMID:26098695

  15. Development of a nanogold slot blot inhibition assay for the detection of antibodies against bovine herpesvirus type 1.

    PubMed

    Japolla, Greice; Cunha-Junior, Jair Pereira; Pajuaba, Ana Claudia Arantes Marquez; Taketomi, Ernesto Akio; Bührer-Sékula, Samira; Bataus, Luiz Artur Mendes; de Souza, Guilherme Rocha Lino

    2018-06-01

    Bovine herpesvirus type 1 (BoHV-1) is recognized as an important pathogen causing respiratory, reproductive, and neurological disorders in cattle and is associated with economic losses to animal industry. Accurate diagnostic methods are needed for prevention of disease transmission. While the virus neutralization test is considered the gold standard method, it requires maintenance of the virus and cell cultures, which is time consuming and expensive. Serological techniques such as enzyme-linked immunosorbent assay (ELISA) are widely applied, as these are easy to perform and provide quick results. In the present study, a nanogold slot blot inhibition assay was developed for the serological diagnosis of BoHV-1 and compared with standard ELISA and horseradish peroxidase (HRP) slot blot assays. Of 42 serum samples tested by ELISA, 32 (76.2%) were positive and 10 (23.8%), were negative. The sensitivity and specificity of the nanogold slot blot inhibition assay was similar to that observed for ELISA and HRP slot blot assays, and a strong correlation was observed between the tests. Thus, the nanogold slot blot inhibition assay may serve as an efficient and rapid alternative to ELISA in settings, where plate-reading equipment is lacking.

  16. [Efficacy of absorbance ratio of ELISA antibodies [corrected] for hepatitis C virus of 3th generation in the prediction of viremia evaluated by PCR].

    PubMed

    Vázquez-Avila, Isidro; Vera-Peralta, Jorge Manuel; Alvarez-Nemegyei, José; Rodríguez-Carvajal, Otilia

    2007-01-01

    In order to decrease the burden of suffering and the costs derived from confirmatory molecular assays, a better strategy is badly needed to decrease the rate of false positive results of the enzyme-linked immunoassay (ELISA) for detection of hepatitis C virus (HCV) antibodies (Anti). To establish the best cutoff of the S/CO rate in subjects with a positive result of a microparticule, third generation ELISA assay for Anti-HCV, for predicting viremia as detected by polymerase chain reaction (PCR) assay. Using the result of the PCR assay as "gold standard", a ROC curve was build with the results of the S/CO rate values in subjects with a positive result for ELISA HCV assay. Fifty two subjects (30 male, 22 female, 40 +/- 12.5 years old) were included. Thirty four (65.3%) had a positive RNA HCV PCR assay. The area under the curve was 0.99 (95% CI: 0.98-1.0). The optimal cutoff for the S/CO rate was established in 29: sensitivity: 97%; specificity: 100%: PPV: 100%; NPV: 94%. Setting the cutoff of the S/CO in 29 results in a high predictive value for viremia as detected by PCR in subjects with a positive ELISA HVC assay. This knowledge may result in a better decision taking for the clinical follow up of those subjects with a positive result in the ELISA screening assay for HCV infection.

  17. EVALUATION OF AN ENZYME-LINKED IMMUNOSORBENT ASSAY FOR BIOLOGICAL MONITORING OF 3-PHENOXYBENZOIC ACID IN URINE

    EPA Science Inventory

    Abstract describes the development of an enzyme-linked immunosorbent assay (ELISA) method for monitoring 2,4-dichlorophenoxyacetic acid (2,4-D exposures). The ELISA is compared with a gas chromatograhy/mass spectrometry procedure. ELISA method development steps and comparative ...

  18. Autoantigen microarrays reveal autoantibodies associated with proliferative nephritis and active disease in pediatric systemic lupus erythematosus.

    PubMed

    Haddon, D James; Diep, Vivian K; Price, Jordan V; Limb, Cindy; Utz, Paul J; Balboni, Imelda

    2015-06-17

    Pediatric systemic lupus erythematosus (pSLE) patients often initially present with more active and severe disease than adults, including a higher frequency of lupus nephritis. Specific autoantibodies, including anti-C1q, anti-DNA and anti-alpha-actinin, have been associated with kidney involvement in SLE, and DNA antibodies are capable of initiating early-stage lupus nephritis in severe combined immunodeficiency (SCID) mice. Over 100 different autoantibodies have been described in SLE patients, highlighting the need for comprehensive autoantibody profiling. Knowledge of the antibodies associated with pSLE and proliferative nephritis will increase the understanding of SLE pathogenesis, and may aid in monitoring patients for renal flare. We used autoantigen microarrays composed of 140 recombinant or purified antigens to compare the serum autoantibody profiles of new-onset pSLE patients (n = 45) to healthy controls (n = 17). We also compared pSLE patients with biopsy-confirmed class III or IV proliferative nephritis (n = 23) and without significant renal involvement (n = 18). We performed ELISA with selected autoantigens to validate the microarray findings. We created a multiple logistic regression model, based on the ELISA and clinical information, to predict whether a patient had proliferative nephritis, and used a validation cohort (n = 23) and longitudinal samples (88 patient visits) to test its accuracy. Fifty autoantibodies were at significantly higher levels in the sera of pSLE patients compared to healthy controls, including anti-B cell-activating factor (BAFF). High levels of anti-BAFF were associated with active disease. Thirteen serum autoantibodies were present at significantly higher levels in pSLE patients with proliferative nephritis than those without, and we confirmed five autoantigens (dsDNA, C1q, collagens IV and X and aggrecan) by ELISA. Our model, based on ELISA measurements and clinical variables, correctly identified patients with proliferative nephritis with 91 % accuracy. Autoantigen microarrays are an ideal platform for identifying autoantibodies associated with both pSLE and specific clinical manifestations of pSLE. Using multiple regression analysis to integrate autoantibody and clinical data permits accurate prediction of clinical manifestations with complex etiologies in pSLE.

  19. Therapeutic drug monitoring of infliximab: performance evaluation of three commercial ELISA kits.

    PubMed

    Schmitz, Ellen M H; van de Kerkhof, Daan; Hamann, Dörte; van Dongen, Joost L J; Kuijper, Philip H M; Brunsveld, Luc; Scharnhorst, Volkher; Broeren, Maarten A C

    2016-07-01

    Therapeutic drug monitoring (TDM) of infliximab (IFX, Remicade®) can aid to optimize therapy efficacy. Many assays are available for this purpose. However, a reference standard is lacking. Therefore, we evaluated the analytical performance, agreement and clinically relevant differences of three commercially available IFX ELISA kits on an automated processing system. The kits of Theradiag (Lisa Tracker Infliximab), Progenika (Promonitor IFX) and apDia (Infliximab ELISA) were implemented on an automated processing system. Imprecision was determined by triplicate measurements of patient samples on five days. Agreement was evaluated by analysis of 30 patient samples and four spiked samples by the selected ELISA kits and the in-house IFX ELISA of Sanquin Diagnostics (Amsterdam, The Netherlands). Therapeutic consequences were evaluated by dividing patients into four treatment groups using cut-off levels of 1, 3 and 7 μg/mL and determining assay concordance. Within-run and between-run imprecision were acceptable (≤12% and ≤17%, respectively) within the quantification range of the selected ELISA kits. The apDia assay had the best precision and agreement to target values. Statistically significant differences were found between all assays except between Sanquin Diagnostics and the Lisa Tracker assay. The Promonitor assay measured the lowest IFX concentrations, the apDia assay the highest. When patients were classified in four treatment categories, 70% concordance was achieved. Although all assays are suitable for TDM, significant differences were observed in both imprecision and agreement. Therapeutic consequences were acceptable when patients were divided in treatment categories, but this could be improved by assay standardization.

  20. Microarray-integrated optoelectrofluidic immunoassay system

    PubMed Central

    Han, Dongsik

    2016-01-01

    A microarray-based analytical platform has been utilized as a powerful tool in biological assay fields. However, an analyte depletion problem due to the slow mass transport based on molecular diffusion causes low reaction efficiency, resulting in a limitation for practical applications. This paper presents a novel method to improve the efficiency of microarray-based immunoassay via an optically induced electrokinetic phenomenon by integrating an optoelectrofluidic device with a conventional glass slide-based microarray format. A sample droplet was loaded between the microarray slide and the optoelectrofluidic device on which a photoconductive layer was deposited. Under the application of an AC voltage, optically induced AC electroosmotic flows caused by a microarray-patterned light actively enhanced the mass transport of target molecules at the multiple assay spots of the microarray simultaneously, which reduced tedious reaction time from more than 30 min to 10 min. Based on this enhancing effect, a heterogeneous immunoassay with a tiny volume of sample (5 μl) was successfully performed in the microarray-integrated optoelectrofluidic system using immunoglobulin G (IgG) and anti-IgG, resulting in improved efficiency compared to the static environment. Furthermore, the application of multiplex assays was also demonstrated by multiple protein detection. PMID:27190571

  1. Microarray-integrated optoelectrofluidic immunoassay system.

    PubMed

    Han, Dongsik; Park, Je-Kyun

    2016-05-01

    A microarray-based analytical platform has been utilized as a powerful tool in biological assay fields. However, an analyte depletion problem due to the slow mass transport based on molecular diffusion causes low reaction efficiency, resulting in a limitation for practical applications. This paper presents a novel method to improve the efficiency of microarray-based immunoassay via an optically induced electrokinetic phenomenon by integrating an optoelectrofluidic device with a conventional glass slide-based microarray format. A sample droplet was loaded between the microarray slide and the optoelectrofluidic device on which a photoconductive layer was deposited. Under the application of an AC voltage, optically induced AC electroosmotic flows caused by a microarray-patterned light actively enhanced the mass transport of target molecules at the multiple assay spots of the microarray simultaneously, which reduced tedious reaction time from more than 30 min to 10 min. Based on this enhancing effect, a heterogeneous immunoassay with a tiny volume of sample (5 μl) was successfully performed in the microarray-integrated optoelectrofluidic system using immunoglobulin G (IgG) and anti-IgG, resulting in improved efficiency compared to the static environment. Furthermore, the application of multiplex assays was also demonstrated by multiple protein detection.

  2. Pertussis serology: assessment of IgG anti-PT ELISA for replacement of the CHO cell assay*

    PubMed Central

    DALBY, TINE; SØRENSEN, CHARLOTTE; PETERSEN, JESPER WESTPHAL; KROGFELT, KAREN ANGELIKI

    2010-01-01

    Dalby T, Sørensen C, Petersen JW, Krogfelt KA. Pertussis serology: assessment of IgG anti-PT ELISA for replacement of the CHO cell assay. APMIS 2010; 118: 968–72. Two types of serological assays are commonly used for the assessment of pertussis vaccine-induced antibodies; the Chinese hamster ovary cell (CHO cell) assay and the immunoglobulin G (IgG) anti pertussis toxin (PT) enzyme-linked immunosorbent assay (IgG anti-PT ELISA). Recently, both the techniques have been modified to improve performance with sera with interfering activity (CHO cell assay) or with heat-treated sera (IgG anti-PT ELISA). These two improved techniques were compared by the analysis of 100 individual serum samples from a previous clinical trial and 213 sera from a longitudinal serum collection from 20 Danish adults recently vaccinated with the Danish acellular pertussis vaccine. The comparison showed a significant linear correlation between the results of the two assays with a p-value of <0.0001 for the 100 individual samples. We, therefore, conclude that the improved IgG anti-PT ELISA can be used as a replacement for the often troublesome and time-consuming CHO cell assay for the measurement of vaccine-induced human antibodies to PT. PMID:21091778

  3. Use of diagnostic accuracy as a metric for evaluating laboratory proficiency with microarray assays using mixed-tissue RNA reference samples.

    PubMed

    Pine, P S; Boedigheimer, M; Rosenzweig, B A; Turpaz, Y; He, Y D; Delenstarr, G; Ganter, B; Jarnagin, K; Jones, W D; Reid, L H; Thompson, K L

    2008-11-01

    Effective use of microarray technology in clinical and regulatory settings is contingent on the adoption of standard methods for assessing performance. The MicroArray Quality Control project evaluated the repeatability and comparability of microarray data on the major commercial platforms and laid the groundwork for the application of microarray technology to regulatory assessments. However, methods for assessing performance that are commonly applied to diagnostic assays used in laboratory medicine remain to be developed for microarray assays. A reference system for microarray performance evaluation and process improvement was developed that includes reference samples, metrics and reference datasets. The reference material is composed of two mixes of four different rat tissue RNAs that allow defined target ratios to be assayed using a set of tissue-selective analytes that are distributed along the dynamic range of measurement. The diagnostic accuracy of detected changes in expression ratios, measured as the area under the curve from receiver operating characteristic plots, provides a single commutable value for comparing assay specificity and sensitivity. The utility of this system for assessing overall performance was evaluated for relevant applications like multi-laboratory proficiency testing programs and single-laboratory process drift monitoring. The diagnostic accuracy of detection of a 1.5-fold change in signal level was found to be a sensitive metric for comparing overall performance. This test approaches the technical limit for reliable discrimination of differences between two samples using this technology. We describe a reference system that provides a mechanism for internal and external assessment of laboratory proficiency with microarray technology and is translatable to performance assessments on other whole-genome expression arrays used for basic and clinical research.

  4. Screening for Protein-DNA Interactions by Automatable DNA-Protein Interaction ELISA

    PubMed Central

    Schüssler, Axel; Kolukisaoglu, H. Üner; Koch, Grit; Wallmeroth, Niklas; Hecker, Andreas; Thurow, Kerstin; Zell, Andreas; Harter, Klaus; Wanke, Dierk

    2013-01-01

    DNA-binding proteins (DBPs), such as transcription factors, constitute about 10% of the protein-coding genes in eukaryotic genomes and play pivotal roles in the regulation of chromatin structure and gene expression by binding to short stretches of DNA. Despite their number and importance, only for a minor portion of DBPs the binding sequence had been disclosed. Methods that allow the de novo identification of DNA-binding motifs of known DBPs, such as protein binding microarray technology or SELEX, are not yet suited for high-throughput and automation. To close this gap, we report an automatable DNA-protein-interaction (DPI)-ELISA screen of an optimized double-stranded DNA (dsDNA) probe library that allows the high-throughput identification of hexanucleotide DNA-binding motifs. In contrast to other methods, this DPI-ELISA screen can be performed manually or with standard laboratory automation. Furthermore, output evaluation does not require extensive computational analysis to derive a binding consensus. We could show that the DPI-ELISA screen disclosed the full spectrum of binding preferences for a given DBP. As an example, AtWRKY11 was used to demonstrate that the automated DPI-ELISA screen revealed the entire range of in vitro binding preferences. In addition, protein extracts of AtbZIP63 and the DNA-binding domain of AtWRKY33 were analyzed, which led to a refinement of their known DNA-binding consensi. Finally, we performed a DPI-ELISA screen to disclose the DNA-binding consensus of a yet uncharacterized putative DBP, AtTIFY1. A palindromic TGATCA-consensus was uncovered and we could show that the GATC-core is compulsory for AtTIFY1 binding. This specific interaction between AtTIFY1 and its DNA-binding motif was confirmed by in vivo plant one-hybrid assays in protoplasts. Thus, the value and applicability of the DPI-ELISA screen for de novo binding site identification of DBPs, also under automatized conditions, is a promising approach for a deeper understanding of gene regulation in any organism of choice. PMID:24146751

  5. ANALYSIS OF SOIL AND DUST SAMPLES FOR POLYCHLORINATED BIPHENYLS BY ENZYME LINKED IMMUNOSORBENT ASSAY (ELISA)

    EPA Science Inventory

    An inhibition enzyme-linked immunosorbent assay (ELISA) was used to determine polychlorinated biphenyls (PCBs) in house dust and soil. Soil and house dust samples were analyzed for PCB by both gas chromatography/electron capture detection (GC/ECD) and ELISA methods. A correlati...

  6. Monoclonal antibodies against human angiotensinogen, their characterization and use in an angiotensinogen enzyme linked immunosorbent assay.

    PubMed

    Rubin, I; Lykkegaard, S; Olsen, A A; Selmer, J; Ballegaard, M

    1988-01-01

    Monoclonal antibodies were produced against human angiotensinogen. An enzyme linked immunosorbent assay (ELISA) was developed using a high affinity monoclonal antibody as catching antibody and a polyclonal rabbit anti human angiotensinogen antibody as detecting antibody in a "sandwich" ELISA. Linear range of the ELISA was 15-450 pmol/l of human angiotensinogen. Intra- and inter- assay variation coefficients were in the range of 2% to 8%. A correlation coefficient, r = 0.97, (n = 20), with values obtained by radioimmunoassay. This correlation coefficient, obtained by using both normal and pregnant sera, confirmed that the ELISA fulfill the requirements for clinical useful assay. Characterization of the antibodies were performed with respect to affinity constant and epitopes.

  7. Comparison and Correlation of Neisseria meningitidis Serogroup B Immunologic Assay Results and Human Antibody Responses following Three Doses of the Norwegian Meningococcal Outer Membrane Vesicle Vaccine MenBvac

    PubMed Central

    Findlow, Jamie; Taylor, Stephen; Aase, Audun; Horton, Rachel; Heyderman, Robert; Southern, Jo; Andrews, Nick; Barchha, Rita; Harrison, Ewan; Lowe, Ann; Boxer, Emma; Heaton, Charlotte; Balmer, Paul; Kaczmarski, Ed; Oster, Philipp; Gorringe, Andrew; Borrow, Ray; Miller, Elizabeth

    2006-01-01

    The prediction of efficacy of Neisseria meningitidis serogroup B (MenB) vaccines is currently hindered due to the lack of an appropriate correlate of protection. For outer membrane vesicle (OMV) vaccines, immunogenicity has primarily been determined by the serum bactericidal antibody (SBA) assay and OMV enzyme-linked immunosorbent assay (ELISA). However, the opsonophagocytic assay (OPA), surface labeling assay, whole blood assay (WBA), and salivary antibody ELISA have been developed although correlation with protection is presently undetermined. Therefore, the aim of the study was to investigate further the usefulness of, and relationships between, MenB immunologic assays. A phase II trial of the OMV vaccine, MenBvac, with proven efficacy was initiated to compare immunologic assays incorporating the vaccine and six heterologous strains. Correlations were achieved between the SBA assay, OMV ELISA, and OPA using human polymorphonuclear leukocytes and human complement but not between an OPA using HL60 phagocytic cells and baby rabbit complement. Correlations between the surface labeling assay, the SBA assay, and the OMV ELISA were promising, although target strain dependent. Correlations between the salivary antibody ELISA and other assays were poor. Correlations to the WBA were prevented since many samples had results greater than the range of the assay. The study confirmed the immunogenicity and benefit of a third dose of MenBvac against the homologous vaccine strain using a variety of immunologic assays. These results emphasize the need for standardized methodologies that would allow a more robust comparison of assays between laboratories and promote their further evaluation as correlates of protection against MenB disease. PMID:16861642

  8. A multiplex reverse transcription PCR and automated electronic microarray assay for detection and differentiation of seven viruses affecting swine.

    PubMed

    Erickson, A; Fisher, M; Furukawa-Stoffer, T; Ambagala, A; Hodko, D; Pasick, J; King, D P; Nfon, C; Ortega Polo, R; Lung, O

    2018-04-01

    Microarray technology can be useful for pathogen detection as it allows simultaneous interrogation of the presence or absence of a large number of genetic signatures. However, most microarray assays are labour-intensive and time-consuming to perform. This study describes the development and initial evaluation of a multiplex reverse transcription (RT)-PCR and novel accompanying automated electronic microarray assay for simultaneous detection and differentiation of seven important viruses that affect swine (foot-and-mouth disease virus [FMDV], swine vesicular disease virus [SVDV], vesicular exanthema of swine virus [VESV], African swine fever virus [ASFV], classical swine fever virus [CSFV], porcine respiratory and reproductive syndrome virus [PRRSV] and porcine circovirus type 2 [PCV2]). The novel electronic microarray assay utilizes a single, user-friendly instrument that integrates and automates capture probe printing, hybridization, washing and reporting on a disposable electronic microarray cartridge with 400 features. This assay accurately detected and identified a total of 68 isolates of the seven targeted virus species including 23 samples of FMDV, representing all seven serotypes, and 10 CSFV strains, representing all three genotypes. The assay successfully detected viruses in clinical samples from the field, experimentally infected animals (as early as 1 day post-infection (dpi) for FMDV and SVDV, 4 dpi for ASFV, 5 dpi for CSFV), as well as in biological material that were spiked with target viruses. The limit of detection was 10 copies/μl for ASFV, PCV2 and PRRSV, 100 copies/μl for SVDV, CSFV, VESV and 1,000 copies/μl for FMDV. The electronic microarray component had reduced analytical sensitivity for several of the target viruses when compared with the multiplex RT-PCR. The integration of capture probe printing allows custom onsite array printing as needed, while electrophoretically driven hybridization generates results faster than conventional microarrays that rely on passive hybridization. With further refinement, this novel, rapid, highly automated microarray technology has potential applications in multipathogen surveillance of livestock diseases. © 2017 Her Majesty the Queen in Right of Canada • Transboundary and Emerging Diseases.

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hsia, Chu Chieh; Chizhikov, Vladimir E.; Yang, Amy X.

    Hepatitis B virus (HBV), hepatitis C virus (HCV), and human immunodeficiency virus type-1 (HIV-1) are transfusion-transmitted human pathogens that have a major impact on blood safety and public health worldwide. We developed a microarray multiplex assay for the simultaneous detection and discrimination of these three viruses. The microarray consists of 16 oligonucleotide probes, immobilized on a silylated glass slide. Amplicons from multiplex PCR were labeled with Cy-5 and hybridized to the microarray. The assay detected 1 International Unit (IU), 10 IU, 20 IU of HBV, HCV, and HIV-1, respectively, in a single multiplex reaction. The assay also detected and discriminatedmore » the presence of two or three of these viruses in a single sample. Our data represent a proof-of-concept for the possible use of highly sensitive multiplex microarray assay to screen and confirm the presence of these viruses in blood donors and patients.« less

  10. Detection of fish antigens aerosolized during fish processing using newly developed immunoassays.

    PubMed

    Lopata, Andreas L; Jeebhay, Mohamed F; Reese, Gerald; Fernandes, Joshua; Swoboda, Ines; Robins, Thomas G; Lehrer, Samuel B

    2005-09-01

    Aerosolization of fish proteins during seafood processing has been identified as a potential route for allergic sensitization and occupational asthma among workers involved in high-risk activities. The aim of this study was to develop immunological assays for the quantification of aerosolized fish antigens in a fish-processing factory. Polyclonal antibodies to the main fish species processed in the factory (anchovy and pilchard) were generated in rabbits and compared by ELISA inhibition assay and immunoblotting. These antisera were utilized to develop ELISA assays for the detection of fish antigens. The ELISA inhibition assays were evaluated by analyzing environmental air samples collected from three areas in a fish-processing factory: pilchard canning, fish meal production and lobster processing. By immunoblotting, the rabbit polyclonal antibodies demonstrated IgG antibody binding patterns comparable with IgE antibodies of fish-sensitized patients, particularly in regard to the major fish allergens parvalbumins. The sensitivity of the fish-specific ELISA assays developed was 0.5 microg/ml. The ELISA inhibition assays were able to differentiate between the two different fish species of interest but did not recognize a crustacean species. Notable differences in exposure levels to canned pilchard and anchovy antigens were demonstrated in the three different working areas of the factory, with assays having a detection limit as low as 105 ng/m(3). These ELISA-based assays are sensitive and specific to quantify differential exposure levels to fish antigens produced during fish processing, making it possible to investigate exposure-disease response relationships among workers in this industry. Copyright (c) 2005 S. Karger AG, Basel.

  11. AN ELISA ASSAY FOR HEME OXYGENASE (HO-1)

    EPA Science Inventory

    An ELISA assay for heme oxygenase (HO-l )

    Abstract

    A double antibody capture ELISA for the HO-l protein has been developed to separately quantitate HO-I protein. The use of 2.5% NP40 detergent greatly assists in freeing HO-l protein from membranes and/or other cel...

  12. 75 FR 32184 - Government-Owned Inventions; Availability for Licensing

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-07

    ... ELISA for Detection of Serum Levels of Soluble IL-15 Receptor Alpha Description of Invention: The invention is an ELISA based assay that can be used in the clinical setting to detect the presence of soluble...-15R expression. Advantages: The assay is in the industry accepted ELISA format. This non-radioactive...

  13. Multi-Laboratory Study of Five Methods for the Determination of Brevetoxins in Shellfish Tissue Extracts.

    PubMed

    Dickey, Robert W; Plakas, Steven M; Jester, Edward L E; El Said, Kathleen R; Johannessen, Jan N; Flewelling, Leanne J; Scott, Paula; Hammond, Dan G; Van Dolah, Frances M; Leighfield, Tod A; Bottein Dachraoui, Marie-Yasmine; Ramsdell, John S; Pierce, Richard H; Henry, Mike S; Poli, Mark A; Walker, Calvin; Kurtz, Jan; Naar, Jerome; Baden, Daniel G; Musser, Steve M; White, Kevin D; Truman, Penelope; Miller, Aaron; Hawryluk, Timothy P; Wekell, Marleen M; Stirling, David; Quilliam, Michael A; Lee, Jung K

    A thirteen-laboratory comparative study tested the performance of four methods as alternatives to mouse bioassay for the determination of brevetoxins in shellfish. The methods were N2a neuroblastoma cell assay, two variations of the sodium channel receptor binding assay, competitive ELISA, and LC/MS. Three to five laboratories independently performed each method using centrally prepared spiked and naturally incurred test samples. Competitive ELISA and receptor binding (96-well format) compared most favorably with mouse bioassay. Between-laboratory relative standard deviations (RSDR) ranged from 10 to 20% for ELISA and 14 to 31% for receptor binding. Within-laboratory (RSDr) ranged from 6 to 15% for ELISA, and 5 to 31% for receptor binding. Cell assay was extremely sensitive but data variation rendered it unsuitable for statistical treatment. LC/MS performed as well as ELISA on spiked test samples but was inordinately affected by lack of toxin-metabolite standards, uniform instrumental parameters, or both, on incurred test samples. The ELISA and receptor binding assay are good alternatives to mouse bioassay for the determination of brevetoxins in shellfish.

  14. Indirect ELISA (iELISA) for routine detection of antibodies against Minute Virus of Mice (MVM) in mice colonies.

    PubMed

    Laborde, Juan M; Sguazza, Guillermo H; Fuentealba, Nadia A; Corva, Santiago G; Carbone, Cecilia; Galosi, Cecilia M

    In this study we developed an indirect ELISA to detect antibodies against Minute Virus of Mice (MVM) using an antigen produced from BHK-21 cells infected with a prototype strain of the virus. The optimal antigen concentration and serum dilutions were established. In order to analyze variability in the laboratory, reproducibility and repeatability within and between plates were determined. Then, a panel of 460 sera from conventional facilities and previously classified as positive or negative by the indirect fluorescent antibody assay was analyzed. The cutoff value was determined by a receiver operating characteristic (ROC) curve. The results of the indirect ELISA were compared with those of the indirect fluorescent antibody assay. The ELISA assay showed 100% sensitivity and 99% specificity. ELISA is a useful tool to be developed in standard virology laboratories and can be used for screening animals faster than the traditional indirect fluorescent antibody assay. Copyright © 2017 Asociación Argentina de Microbiología. Publicado por Elsevier España, S.L.U. All rights reserved.

  15. Adaptive Focused Acoustics (AFA) Improves the Performance of Microtiter Plate ELISAs.

    PubMed

    Green, David J; Rudd, Edwin A; Laugharn, James A

    2014-08-01

    We investigated the use of Adaptive Focused Acoustics (AFA) technology to improve the performance of microtiter plate enzyme-linked immunosorbent assays (ELISAs). Experiments were performed with commercially available AFA instrumentation and off-the-shelf 96-well microtiter plate sandwich ELISAs. AFA was applied over a range of acoustic energies, temperatures, and durations to the antigen/antibody binding step of an ELISA for measuring HIV-1 p24 in tissue culture samples. AFA-mediated antigen/antibody binding was enhanced up to 2-fold over passive binding at comparable temperatures and was superior or comparable at low temperature (8-10 °C) to passive binding at 37 °C. Lower nonspecific binding (NSB), lower inter- and intra-assay coefficients of variation (CVs), higher Z' factors, and lower limits of detection (LODs) were measured in AFA-mediated assays compared with conventional passive binding. In a more limited study, AFA enhancement of antigen/antibody binding and lower NSB was measured in an ELISA for measuring IGFBP-3 in human plasma. We conclude from this study that application of AFA to antigen/antibody binding steps in microtiter plate ELISAs can enhance key assay performance parameters, particularly Z' factors and LODs. These features render AFA-mediated binding assays potentially more useful in applications such as high-throughput screening and in vitro diagnostics than assays processed with conventional passive antigen/antibody binding steps. © 2014 Society for Laboratory Automation and Screening.

  16. Diagnosis of Zika Virus Infection by Peptide Array and Enzyme-Linked Immunosorbent Assay.

    PubMed

    Mishra, Nischay; Caciula, Adrian; Price, Adam; Thakkar, Riddhi; Ng, James; Chauhan, Lokendra V; Jain, Komal; Che, Xiaoyu; Espinosa, Diego A; Montoya Cruz, Magelda; Balmaseda, Angel; Sullivan, Eric H; Patel, Jigar J; Jarman, Richard G; Rakeman, Jennifer L; Egan, Christina T; Reusken, Chantal B E M; Koopmans, Marion P G; Harris, Eva; Tokarz, Rafal; Briese, Thomas; Lipkin, W Ian

    2018-03-06

    Zika virus (ZIKV) is implicated in fetal stillbirth, microcephaly, intracranial calcifications, and ocular anomalies following vertical transmission from infected mothers. In adults, infection may trigger autoimmune inflammatory polyneuropathy. Transmission most commonly follows the bite of infected Aedes mosquitoes but may also occur through sexual intercourse or receipt of blood products. Definitive diagnosis through detection of viral RNA is possible in serum or plasma within 10 days of disease onset, in whole blood within 3 weeks of onset, and in semen for up to 3 months. Serological diagnosis is nonetheless critical because few patients have access to molecular diagnostics during the acute phase of infection and infection may be associated with only mild or inapparent disease that does not prompt molecular testing. Serological diagnosis is confounded by cross-reactivity of immune sera with other flaviviruses endemic in the areas where ZIKV has recently emerged. Accordingly, we built a high-density microarray comprising nonredundant 12-mer peptides that tile, with one-residue overlap, the proteomes of Zika, dengue, yellow fever, West Nile, Ilheus, Oropouche, and chikungunya viruses. Serological analysis enabled discovery of a ZIKV NS2B 20-residue peptide that had high sensitivity (96.0%) and specificity (95.9%) versus natural infection with or vaccination against dengue, chikungunya, yellow fever, West Nile, tick-borne encephalitis, or Japanese encephalitis virus in a microarray assay and an enzyme-linked immunosorbent assay (ELISA) of early-convalescent-phase sera (2 to 3 weeks after onset of symptomatic infection). IMPORTANCE The emergence of Zika virus (ZIKV) as a teratogen is a profound challenge to global public health. Molecular diagnosis of infection is straightforward during the 3-week period when patients are viremic. However, serological diagnosis thereafter of historical exposure has been confounded by cross-reactivity. Using high-density peptide arrays that tile the proteomes of a selection of flaviviruses to identify a ZIKV-specific peptide, we established two assays that enable sensitive and specific diagnosis of exposure to ZIKV. These assays may be useful in guiding clinical management of mothers at risk for potential exposure to ZIKV and enable insights into the epidemiology of ZIKV infections.

  17. Multiplex array proteomics detects increased MMP-8 in CSF after spinal cord injury.

    PubMed

    Light, Matthew; Minor, Kenneth H; DeWitt, Peter; Jasper, Kyle H; Davies, Stephen J A

    2012-06-11

    A variety of methods have been used to study inflammatory changes in the acutely injured spinal cord. Recently novel multiplex assays have been used in an attempt to overcome limitations in numbers of available targets studied in a single experiment. Other technical challenges in developing pre-clinical rodent models to investigate biomarkers in cerebrospinal fluid (CSF) include relatively small volumes of sample and low concentrations of target proteins. The primary objective of this study was to characterize the inflammatory profile present in CSF at a subacute time point in a clinically relevant rodent model of traumatic spinal cord injury (SCI). Our other aim was to test a microarray proteomics platform specifically for this application. A 34 cytokine sandwich ELISA microarray was used to study inflammatory changes in CSF samples taken 12 days post-cervical SCI in adult rats. The difference between the median foreground signal and the median background signal was measured. Bonferroni and Benjamini-Hochburg multiple testing corrections were applied to limit the False Discovery Rate (FDR), and a linear mixed model was used to account for repeated measures in the array. We report a novel subacute SCI biomarker, elevated levels of matrix metalloproteinase-8 protein in CSF, and discuss application of statistical models designed for multiplex testing. Major advantages of this assay over conventional methods include high-throughput format, good sensitivity, and reduced sample consumption. This method can be useful for creating comprehensive inflammatory profiles, and biomarkers can be used in the clinic to assess injury severity and to objectively grade response to therapy.

  18. The plasma interleukin-6 response to acute psychosocial stress in humans is detected by a magnetic multiplex assay: comparison to high-sensitivity ELISA.

    PubMed

    Quinn, Andrea M; Williams, Allison R; Sivilli, Teresa I; Raison, Charles L; Pace, Thaddeus W W

    2018-03-13

    Circulating concentrations of interleukin (IL)-6, an inflammatory biomarker widely assessed in humans to study the inflammatory response to acute psychological stress, have for decades been quantified using enzyme-linked immunosorbent assay (ELISA). However, biobehavioral researchers are increasingly using cytokine multiplex assays instead of ELISA to measure IL-6 and other cytokines. Despite this trend, multiplex assays have not been directly compared to ELISA for their ability to detect subtle stress-induced changes of IL-6. Here, we tested the prediction that a high-sensitivity multiplex assay (human Magnetic Luminex Performance Assay, R&D Systems, Minneapolis, MN) would detect changes in IL-6 as a result of acute stress challenge in a manner comparable to high-sensitivity ELISA. Blood was collected from 12 healthy adults immediately before and then 90 and 210 min after the start of the Trier Social Stress Test (TSST), an acute laboratory psychosocial stress challenge. In addition to quantifying IL-6 concentrations in plasma with both multiplex and ELISA, we also assessed concentrations of tumor necrosis factor-alpha, IL-8, IL-10, IL-5, and IL-2 with multiplex. The multiplex detected IL-6 in all samples. Concentrations strongly correlated with values determined by ELISA across all samples (r = 0.941, p < .001) as well as among samples collected at individual TSST time points. IL-6 responses to the TSST (i.e. area under the curve) captured by multiplex and ELISA were also strongly correlated (r s   = 0.937, p < .001). While other cytokines were detected by multiplex, none changed as a result of TSST challenge at time points examined. These results suggest high-sensitivity magnetic multiplex assay is able to detect changes in plasma concentrations of IL-6 as a result of acute stress in humans.

  19. Development of an Assay for the Detection of PrPres in Blood and Urine Based on PMCA Assay and ELISA Methods

    DTIC Science & Technology

    2008-09-01

    the Origen Analyzer (BioVeris), the DELFIA (Wallac/PE) and the MPD ELISA ( BioTraces ). BioTraces had the most sensitive assay in which 125I was used...investigations we decided to abandon the BioTraces assay and focused on a more practical and also sensitive assay provided by the Origen Analyzer

  20. Comparison of two assays for detection of antibodies against canine parvovirus and canine distemper virus in dogs admitted to a Florida animal shelter.

    PubMed

    Gray, Lauren K; Crawford, P Cynda; Levy, Julie K; Dubovi, Edward J

    2012-05-01

    To compare 2 assays for use in the identification of dogs with a protective antibody titer (PAT) against canine parvovirus (CPV) and canine distemper virus (CDV). Prospective cross-sectional study. 431 dogs admitted to a municipal animal shelter in north central Florida. Blood samples were collected from dogs on the day of admission to the shelter. Serum was obtained, criterion-referenced assays were used to identify dogs that had PATs against CPV (titers ≥ 80; hemagglutination inhibition assay) and CDV (titers ≥ 32; virus neutralization assay), and results were compared with results of a semiquantitative ELISA and an immunofluorescence assay (IFA). For correct identification of dogs that had PATs against viruses, the ELISA had significantly higher specificity for CPV (98%) and CDV (95%) than did the IFA (82% and 70%, respectively) and had significantly lower sensitivity for CDV (88%) than did the IFA (97%); the sensitivity for CPV was similar (ELISA, 98%; IFA, 97%). Overall diagnostic accuracy was significantly greater with the ELISA than with the IFA. Predictive value of a positive result for PATs was significantly higher with the ELISA for CPV (99%) and CDV (93%) than with the IFA (92% and 71%, respectively). The ELISA had fewer false-positive results than did the IFA and could be performed on-site in shelters in < 1 hour. Accuracy and practicality of the ELISA may be useful for identifying the infection risk of dogs exposed during outbreaks attributable to CPV and CDV infections in shelters.

  1. Effect of time since exposure to Chlamydia trachomatis on chlamydia antibody detection in women: a cross-sectional study.

    PubMed

    Horner, Patrick J; Wills, Gillian S; Reynolds, Rosy; Johnson, Anne M; Muir, David A; Winston, Alan; Broadbent, Andrew J; Parker, David; McClure, Myra O

    2013-08-01

    To investigate what factors influence the detection of Chlamydia trachomatis antibody following genital tract infection. One hundred and sixty-four women with a previous history of C trachomatis infection contributed to an earlier report on the performance of chlamydia antibody ELISA assays. We undertook further analysis to explore how chlamydia antibody assay sensitivity changes with time since infection. Chlamydia antibody was detected in more women soon after the last detection of chlamydia at the lower genital tract than at later times. This holds true for all tests, but the Anilabsystems IgG EIA, Medac pELISA plus ELISA and the Savyon SeroCT-IgG ELISA were less sensitive than the pgp3 ELISA and the Anilabsystems microimmunofluorescence (MIF) assay at all time points except during current infection. Fall in seropositivity in women generally occurred in the early weeks and months following the last episode of chlamydia infection. There was no clear pattern of further reduction in seropositivity after 6 months. Multiple previous episodes were associated with increased seropositivity in the pgp3 assay (two or more vs one, OR 19, p<0.001) and other tests, but the effect was significantly smaller for the Anilabs, Medac and SeroCT MOMP peptide ELISAs, but not for the MIF assay. Chlamydia antibody detection decreases with time since infection and this is most apparent in the first 6 months. In women who have had more than one infection, antibody remained detectable longer for all tests, but this was more marked for the pgp3 ELISA and MIF assay.

  2. Immunoenzyme assay of nonylphenol: study of selectivity and detection of alkylphenolic non-ionic surfactants in water samples.

    PubMed

    Mart'ianov, Andrey A; Dzantiev, Boris B; Zherdev, Anatoly V; Eremin, Sergei A; Cespedes, Raquel; Petrovic, Mira; Barcelo, Damia

    2005-01-30

    Immunoenzyme assay (ELISA) is proposed and characterized for determination of alkylphenol ethoxylates, a primary class of manufactured non-ionic surfactants. The assay is based on the obtained polyclonal antibodies against nonylphenol (NP), the main stable intermediate of the decomposition of nonylphenol ethoxylates. A mixture of non-modified branched isomers of NP was applied as hapten coupled to protein carriers by Mannich reaction with the use of formaldehyde. The proposed ELISA format is based on immobilized NP-(soybean trypsin inhibitor) conjugate as a competitor of antigen molecules contained in the tested sample for binding with specific antibodies indirectly labeled via an anti-species immunoperoxidase conjugate. The developed ELISA allows to reveal NP with the limit of detection about 10ngml(-1) and NP-related compounds such as octylphenol, alkylphenoletoxylates, alkylphenolcarboxylates and their halogenated derivatives. The ELISA was applied for assaying polluted water samples, namely influents and effluents from different wastewater treatment plants (WWTP) and tap water. ELISA and chromatographic data demonstrate good correlation (r = 0.94), while ELISA gives higher values. Due to endocrine disrupting and other toxic activities of some metabolites of alkylphenolic non-ionic surfactants, the developed assay may be effectively used in ecological monitoring and sanitary control.

  3. Pancreatic Reference Set Application- Ann Killary-MD Anderson (2012) — EDRN Public Portal

    Cancer.gov

    ELISA assays. We propose to screen a two gene panel (TNC/TFPI) from functional genomic pathways approaches, by ELISA assays, in a collection of blinded plasma samples with the PCCG. In subsequent years, we will add to this panel additional candidates identified in the parent EDRN grant that are in the migration signature network or the 20q amplicon. For ELISA assays, we will utilize commercially available kits. Plasma levels of the predominant isoform of TNC, TNC-large variant (TNC-L) will be determined using a Human Tenascin-C Large (HMV) (FNIII-B) ELISA kit (IBL-America, Minneapolis, MN), which detects human TNC high molecular weight variant by sandwich ELISA. Plasma TFPI levels will be determined using a commercially available Quantikine Human TFPI ELISA kit (DTFP10) (R&D; Systems, Inc. Minneapolis, MN), which detects predominantly free TFPI and a very small percentage of LDL and HDL-bound TFPI by sandwich ELISA. Additional ELISA assays will be added in years 2-3 using ingenuity network analysis to identify secreted proteins that interact with migration signature proteins identified using functional genomic approaches. In addition, Dr. Sen’s lab has identified candidate biomarkers mapping with the 20q amplicon and which are both amplified and overexpressed as well as are secreted proteins. In years 2-3, we will examine all candidate markers by ELISA to determine 20q pathway markers increase the sensitivity and specificity of the 3p panel. Validation of a 4 miR Panel. For assaying the levels of miRs in plasma, qRT-PCR assays will be performed, as described (9). For the selected panel of miRs, we propose to develop a high throughput qRT-PCR assay by adapting our published method to a 96 well format where the critical steps of purification, such as LiCl precipitation and DNAse treatments will be done in successive steps in the same plates. In years 2-3, additional miRs that target both the 20q amplicon genes as well as miRs that target migration genes in Dr. Killary’

  4. 78 FR 35290 - Government-Owned Inventions; Availability for Licensing

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-12

    ... tissues. NIH researchers have developed ELISA assays to quantify the amount of midkine and pleiotrophin...-available midkine or pleiotrophin antibodies. Assay relies on proven ELISA detection technology. Development...

  5. COMPARISONS OF ELISA AND WESTERN BLOT ASSAYS FOR DETECTION OF CRYPTOSPORIDIUM ANTIBODY

    EPA Science Inventory

    A seroprevalence survey was conducted using ELISA and Western blot (WB) assays for antibody to three Cryptosporidium antigens on 380 blood donors in Jackson County, Oregon. The purpose was to determine if either assay could detect serological evidence of an outbreak which occurre...

  6. BIOPHYSICAL PROPERTIES OF NUCLEIC ACIDS AT SURFACES RELEVANT TO MICROARRAY PERFORMANCE.

    PubMed

    Rao, Archana N; Grainger, David W

    2014-04-01

    Both clinical and analytical metrics produced by microarray-based assay technology have recognized problems in reproducibility, reliability and analytical sensitivity. These issues are often attributed to poor understanding and control of nucleic acid behaviors and properties at solid-liquid interfaces. Nucleic acid hybridization, central to DNA and RNA microarray formats, depends on the properties and behaviors of single strand (ss) nucleic acids (e.g., probe oligomeric DNA) bound to surfaces. ssDNA's persistence length, radius of gyration, electrostatics, conformations on different surfaces and under various assay conditions, its chain flexibility and curvature, charging effects in ionic solutions, and fluorescent labeling all influence its physical chemistry and hybridization under assay conditions. Nucleic acid (e.g., both RNA and DNA) target interactions with immobilized ssDNA strands are highly impacted by these biophysical states. Furthermore, the kinetics, thermodynamics, and enthalpic and entropic contributions to DNA hybridization reflect global probe/target structures and interaction dynamics. Here we review several biophysical issues relevant to oligomeric nucleic acid molecular behaviors at surfaces and their influences on duplex formation that influence microarray assay performance. Correlation of biophysical aspects of single and double-stranded nucleic acids with their complexes in bulk solution is common. Such analysis at surfaces is not commonly reported, despite its importance to microarray assays. We seek to provide further insight into nucleic acid-surface challenges facing microarray diagnostic formats that have hindered their clinical adoption and compromise their research quality and value as genomics tools.

  7. BIOPHYSICAL PROPERTIES OF NUCLEIC ACIDS AT SURFACES RELEVANT TO MICROARRAY PERFORMANCE

    PubMed Central

    Rao, Archana N.; Grainger, David W.

    2014-01-01

    Both clinical and analytical metrics produced by microarray-based assay technology have recognized problems in reproducibility, reliability and analytical sensitivity. These issues are often attributed to poor understanding and control of nucleic acid behaviors and properties at solid-liquid interfaces. Nucleic acid hybridization, central to DNA and RNA microarray formats, depends on the properties and behaviors of single strand (ss) nucleic acids (e.g., probe oligomeric DNA) bound to surfaces. ssDNA’s persistence length, radius of gyration, electrostatics, conformations on different surfaces and under various assay conditions, its chain flexibility and curvature, charging effects in ionic solutions, and fluorescent labeling all influence its physical chemistry and hybridization under assay conditions. Nucleic acid (e.g., both RNA and DNA) target interactions with immobilized ssDNA strands are highly impacted by these biophysical states. Furthermore, the kinetics, thermodynamics, and enthalpic and entropic contributions to DNA hybridization reflect global probe/target structures and interaction dynamics. Here we review several biophysical issues relevant to oligomeric nucleic acid molecular behaviors at surfaces and their influences on duplex formation that influence microarray assay performance. Correlation of biophysical aspects of single and double-stranded nucleic acids with their complexes in bulk solution is common. Such analysis at surfaces is not commonly reported, despite its importance to microarray assays. We seek to provide further insight into nucleic acid-surface challenges facing microarray diagnostic formats that have hindered their clinical adoption and compromise their research quality and value as genomics tools. PMID:24765522

  8. DARPA Antibody Technology Program Standardized Test Bed for Antibody Characterization: Characterization of an MS2 ScFv Antibody

    DTIC Science & Technology

    2016-03-01

    performance in an enzyme-linked immunosorbent assay ( ELISA ), with little regard for quantification of the full spectrum of variables affecting antibody...Program (ATP) Quality MS2 coat protein (MS2CP) Enzyme-linked immunosorbent assay ( ELISA ) 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT...5 2.7 ELISA ................................................................................................................5

  9. Randomized controlled ferret study to assess the direct impact of 2008-09 trivalent inactivated influenza vaccine on A(H1N1)pdm09 disease risk.

    PubMed

    Skowronski, Danuta M; Hamelin, Marie-Eve; De Serres, Gaston; Janjua, Naveed Z; Li, Guiyun; Sabaiduc, Suzana; Bouhy, Xavier; Couture, Christian; Leung, Anders; Kobasa, Darwyn; Embury-Hyatt, Carissa; de Bruin, Erwin; Balshaw, Robert; Lavigne, Sophie; Petric, Martin; Koopmans, Marion; Boivin, Guy

    2014-01-01

    During spring-summer 2009, several observational studies from Canada showed increased risk of medically-attended, laboratory-confirmed A(H1N1)pdm09 illness among prior recipients of 2008-09 trivalent inactivated influenza vaccine (TIV). Explanatory hypotheses included direct and indirect vaccine effects. In a randomized placebo-controlled ferret study, we tested whether prior receipt of 2008-09 TIV may have directly influenced A(H1N1)pdm09 illness. Thirty-two ferrets (16/group) received 0.5 mL intra-muscular injections of the Canadian-manufactured, commercially-available, non-adjuvanted, split 2008-09 Fluviral or PBS placebo on days 0 and 28. On day 49 all animals were challenged (Ch0) with A(H1N1)pdm09. Four ferrets per group were randomly selected for sacrifice at day 5 post-challenge (Ch+5) and the rest followed until Ch+14. Sera were tested for antibody to vaccine antigens and A(H1N1)pdm09 by hemagglutination inhibition (HI), microneutralization (MN), nucleoprotein-based ELISA and HA1-based microarray assays. Clinical characteristics and nasal virus titers were recorded pre-challenge then post-challenge until sacrifice when lung virus titers, cytokines and inflammatory scores were determined. Baseline characteristics were similar between the two groups of influenza-naïve animals. Antibody rise to vaccine antigens was evident by ELISA and HA1-based microarray but not by HI or MN assays; virus challenge raised antibody to A(H1N1)pdm09 by all assays in both groups. Beginning at Ch+2, vaccinated animals experienced greater loss of appetite and weight than placebo animals, reaching the greatest between-group difference in weight loss relative to baseline at Ch+5 (7.4% vs. 5.2%; p = 0.01). At Ch+5 vaccinated animals had higher lung virus titers (log-mean 4.96 vs. 4.23pfu/mL, respectively; p = 0.01), lung inflammatory scores (5.8 vs. 2.1, respectively; p = 0.051) and cytokine levels (p>0.05). At Ch+14, both groups had recovered. Findings in influenza-naïve, systematically-infected ferrets may not replicate the human experience. While they cannot be considered conclusive to explain human observations, these ferret findings are consistent with direct, adverse effect of prior 2008-09 TIV receipt on A(H1N1)pdm09 illness. As such, they warrant further in-depth investigation and search for possible mechanistic explanations.

  10. 77 FR 26294 - Government-Owned Inventions; Availability for Licensing

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-03

    ... ELISA-like assay entirely to the molecular level, complex macroscopic or microfluidic washing and... for ELISA assays Modify or destroy target molecules, while detecting them Detect genetic diseases in...

  11. Indirect immunoglobulin G (IgG) and IgM enzyme-linked immunosorbent assays (ELISAs) and IgM capture ELISA for detection of antibodies to lipopolysaccharide in adult typhoid fever patients in Pakistan.

    PubMed

    Sippel, J; Bukhtiari, N; Awan, M B; Krieg, R; Duncan, J F; Karamat, K A; Malik, I A; Igbal, L M; Legters, L

    1989-06-01

    Sera from 339 adult febrile patients in Pakistan were tested for antibodies to Salmonella typhi lipopolysaccharide by indirect immunoglobulin G (IgG) and IgM enzyme-linked immunosorbent assay (ELISA) and IgM capture ELISA. A total of 55 patients had S. typhi cultured from their blood, 20 had S. typhi cultured from their stool, 24 were blood or stool culture positive for S. paratyphi A, 41 were culture negative but clinically diagnosed as having enteric fever, 41 had gastrointestinal or urinary tract infections, 41 were clinically diagnosed as having malaria, 20 were smear-positive patients with malaria, 58 had respiratory infections, and the remaining 39 individuals were placed in a miscellaneous group who did not have Salmonella infection. The sensitivities of the indirect IgG ELISA, indirect IgM ELISA, and IgM capture ELISA determined with specimens obtained from the blood culture-positive patients with typhoid fever (positive controls) were 80, 64, and 62%, respectively. The specificities of the assays determined with sera from the patients with respiratory infections (negative controls) were 95, 95, and 97%, respectively. The percentage of smear-positive patients with malaria who were positive by these assays was lower than that in the negative control group. The percentages of individuals in the other patient categories who were positive by these tests were between those obtained with the positive and negative controls. Of the positive controls, 26 were positive by both IgM assays, 9 were IgM positive only by indirect ELISA, and 8 were IgM positive only by IgM capture ELISA. A total of 70% of the positive control patients who were tested for O agglutinins by the Widal tube agglutination assay were positive; however, 29% of the negative control patients were also positive. The indirect IgG ELISA was the single most effective test for the serodiagnosis of typhoid fever in this population.

  12. Indirect immunoglobulin G (IgG) and IgM enzyme-linked immunosorbent assays (ELISAs) and IgM capture ELISA for detection of antibodies to lipopolysaccharide in adult typhoid fever patients in Pakistan.

    PubMed Central

    Sippel, J; Bukhtiari, N; Awan, M B; Krieg, R; Duncan, J F; Karamat, K A; Malik, I A; Igbal, L M; Legters, L

    1989-01-01

    Sera from 339 adult febrile patients in Pakistan were tested for antibodies to Salmonella typhi lipopolysaccharide by indirect immunoglobulin G (IgG) and IgM enzyme-linked immunosorbent assay (ELISA) and IgM capture ELISA. A total of 55 patients had S. typhi cultured from their blood, 20 had S. typhi cultured from their stool, 24 were blood or stool culture positive for S. paratyphi A, 41 were culture negative but clinically diagnosed as having enteric fever, 41 had gastrointestinal or urinary tract infections, 41 were clinically diagnosed as having malaria, 20 were smear-positive patients with malaria, 58 had respiratory infections, and the remaining 39 individuals were placed in a miscellaneous group who did not have Salmonella infection. The sensitivities of the indirect IgG ELISA, indirect IgM ELISA, and IgM capture ELISA determined with specimens obtained from the blood culture-positive patients with typhoid fever (positive controls) were 80, 64, and 62%, respectively. The specificities of the assays determined with sera from the patients with respiratory infections (negative controls) were 95, 95, and 97%, respectively. The percentage of smear-positive patients with malaria who were positive by these assays was lower than that in the negative control group. The percentages of individuals in the other patient categories who were positive by these tests were between those obtained with the positive and negative controls. Of the positive controls, 26 were positive by both IgM assays, 9 were IgM positive only by indirect ELISA, and 8 were IgM positive only by IgM capture ELISA. A total of 70% of the positive control patients who were tested for O agglutinins by the Widal tube agglutination assay were positive; however, 29% of the negative control patients were also positive. The indirect IgG ELISA was the single most effective test for the serodiagnosis of typhoid fever in this population. PMID:2754002

  13. Evaluation of Five Antibody Detection Tests for Diagnosis of Bovine Paratuberculosis

    PubMed Central

    Collins, Michael T.; Wells, Scott J.; Petrini, Kristine R.; Collins, James E.; Schultz, Ronald D.; Whitlock, Robert H.

    2005-01-01

    Five diagnostic tests based on enzyme-linked immunosorbent assay (ELISA) technology for bovine paratuberculosis were evaluated by using individual serum or milk samples from 359 dairy cattle in seven paratuberculosis-free herds and 2,094 dairy cattle in seven Mycobacterium paratuberculosis-infected dairy herds. Three independent laboratories using three different culture procedures completed fecal cultures for M. paratuberculosis on these cattle and found 417 cows to be shedding M. paratuberculosis in their feces. An animal that was fecal culture positive for M. paratuberculosis by any of the three laboratories was considered a confirmed case of infection. The specificity of three ELISAs (two on serum and one on milk) was ≥99.8%. The specificity of the remaining two ELISAs, both done on serum, was 94.9 and 84.7%. Four of the five ELISAs evaluated produced similar sensitivity in detecting fecal culture-positive cattle (27.8 to 28.9%). Serum ELISA “D” had the lowest specificity (84.7%) and the highest sensitivity (44.5%), but if the cutoff value defining a positive test was changed from 125 to 250% (of the positive control) the sensitivity and specificity, 31.8 and 97.5%, respectively, were comparable to those of the other four assays. If the case definition for M. paratuberculosis infection was based on the culture results of a single laboratory instead of the combined results of three laboratories, ELISA sensitivity estimates were 45.7 to 50.0%. With the exception of ELISA D, assay agreement was high (kappa 0.66 to 0.85) for categorical assay interpretations (positive or negative), but linear regression of quantitative results showed low correlation coefficients (r2 = 0.40 to 0.68) due to the fact that ELISA results for some cows were high in one assay but low in another assay. Likelihood ratio analysis showed a direct relationship between the magnitude of ELISA result and the odds of a cow shedding M. paratuberculosis in its feces. If used judiciously and interpreted quantitatively, these ELISAs are useful tools in support of paratuberculosis control programs in dairy herds. PMID:15939741

  14. An enzyme-linked immunosorbent assay for detection of botulinum toxin-antibodies.

    PubMed

    Dressler, Dirk; Gessler, Frank; Tacik, Pawel; Bigalke, Hans

    2014-09-01

    Antibodies against botulinum neurotoxin (BNT-AB) can be detected by the mouse protection assay (MPA), the hemidiaphragm assay (HDA), and by enzyme-linked immunosorbent assays (ELISA). Both MPA and HDA require sacrifice of experimental animals, and they are technically delicate and labor intensive. We introduce a specially developed ELISA for detection of BNT-A-AB and evaluate it against the HDA. Thirty serum samples were tested by HDA and by the new ELISA. Results were compared, and receiver operating characteristic analyses were used to optimize ELISA parameter constellation to obtain either maximal overall accuracy, maximal test sensitivity, or maximal test specificity. When the ELISA is optimized for sensitivity, a sensitivity of 100% and a specificity of 55% can be reached. When it is optimized for specificity, a specificity of 100% and a sensitivity of 90% can be obtained. We present an ELISA for BNT-AB detection that can be-for the first time-customized for special purposes. Adjusted for optimal sensitivity, it reaches the best sensitivity of all BNT-AB tests available. Using the new ELISA together with the HDA as a confirmation test allows testing for BNT-AB in large numbers of patients receiving BT drugs in an economical, fast, and more animal-friendly way. © 2014 International Parkinson and Movement Disorder Society.

  15. Blood collected on filter paper for wildlife serology: detecting antibodies to Neospora caninum, West Nile virus, and five bovine viruses in reindeer.

    PubMed

    Curry, Patricia S; Ribble, Carl; Sears, William C; Hutchins, Wendy; Orsel, Karin; Godson, Dale; Lindsay, Robbin; Dibernardo, Antonia; Kutz, Susan J

    2014-04-01

    We compared Nobuto filter paper (FP) whole-blood samples to serum for detecting antibodies to seven pathogens in reindeer (Rangifer tarandus tarandus). Serum and FP samples were collected from captive reindeer in 2008-2009. Sample pairs (serum and FP eluates) were assayed in duplicate at diagnostic laboratories with the use of competitive enzyme-linked immunosorbent assays (cELISAs) for Neospora caninum and West Nile virus (WNV); indirect ELISA (iELISAs) for bovine herpesvirus type 1 (BHV-1), parainfluenza virus type 3 (PI-3), and bovine respiratory syncytial virus (BRSV); and virus neutralization (VN) for bovine viral diarrhea virus (BVDV) types I and II. Assay thresholds were evidence-based values employed by each laboratory. Comparable performance to serum was defined as FP sensitivity and specificity ≥ 80%. Filter-paper specificity estimates ranged from 92% in the cELISAs for N. caninum and WNV to 98% in the iELISAs for PI-3 and BRSV. Sensitivity was >85% for five tests (most ≥ 95%) but was insufficient (71-82%) for the PI-3 and BRSV iELISAs. Lowering the threshold for FP samples in these two ELISAs raised sensitivity to ≥ 87% and reduced specificity slightly (≥ 90% in three of the four test runs). Sample size limited the precision of some performance estimates. Based on the criteria of sensitivity and specificity ≥ 80%, and using adjusted FP thresholds for PI-3 and BRSV, FP sensitivity and specificity were comparable to serum in all seven assays. A potential limitation of FP is reduced sensitivity in tests that require undiluted serum (i.e., N. caninum cELISA and BVDV VNs). Possible toxicity to the assay cell layer in VN requires investigation. Results suggested that cELISA is superior to iELISA for detecting antibodies in FP samples from reindeer and other Rangifer tarandus subspecies. Our findings expand the potential utility of FP sampling from wildlife.

  16. Sensitive and specific enzyme-linked immunosorbent assay for detecting serum antibodies against Mycobacterium avium subsp. paratuberculosis in fallow deer.

    PubMed

    Prieto, José M; Balseiro, Ana; Casais, Rosa; Abendaño, Naiara; Fitzgerald, Liam E; Garrido, Joseba M; Juste, Ramon A; Alonso-Hearn, Marta

    2014-08-01

    The enzyme-linked immunosorbent assay (ELISA) is the diagnostic test most commonly used in efforts to control paratuberculosis in domestic ruminants. However, commercial ELISAs have not been validated for detecting antibodies against Mycobacterium avium subsp. paratuberculosis in wild animals. In this study, we compared the sensitivities and specificities of five ELISAs using individual serum samples collected from 41 fallow deer with or without histopathological lesions consistent with paratuberculosis. Two target antigenic preparations were selected, an ethanol-treated protoplasmic preparation obtained from a fallow deer M. avium subsp. paratuberculosis isolate (ELISAs A and B) and a paratuberculosis protoplasmic antigen (PPA3) (ELISAs C and D). Fallow deer antibodies bound to the immobilized antigens were detected by using a horseradish peroxidase (HRP)-conjugated anti-fallow deer IgG antibody (ELISAs A and C) or HRP-conjugated protein G (ELISAs B and D). A commercially available assay, ELISA-E, which was designed to detect M. avium subsp. paratuberculosis antibodies in cattle, sheep, and goats, was also tested. Although ELISAs A, C, and E had the same sensitivity (72%), ELISAs A and C were more specific (100%) for detecting fallow deer with lesions consistent with paratuberculosis at necropsy than was the ELISA-E (87.5%). In addition, the ELISA-A was particularly sensitive for detecting fallow deer in the latent stages of infection (62.5%). The antibody responses detected with the ELISA-A correlated with both the severity of enteric lesions and the presence of acid-fast bacteria in gut tissue samples. In summary, our study shows that the ELISA-A can be a cost-effective diagnostic tool for preventing the spread of paratuberculosis among fallow deer populations. Copyright © 2014, American Society for Microbiology. All Rights Reserved.

  17. Sensitive and Specific Enzyme-Linked Immunosorbent Assay for Detecting Serum Antibodies against Mycobacterium avium subsp. paratuberculosis in Fallow Deer

    PubMed Central

    Prieto, José M.; Balseiro, Ana; Casais, Rosa; Abendaño, Naiara; Fitzgerald, Liam E.; Garrido, Joseba M.; Juste, Ramon A.

    2014-01-01

    The enzyme-linked immunosorbent assay (ELISA) is the diagnostic test most commonly used in efforts to control paratuberculosis in domestic ruminants. However, commercial ELISAs have not been validated for detecting antibodies against Mycobacterium avium subsp. paratuberculosis in wild animals. In this study, we compared the sensitivities and specificities of five ELISAs using individual serum samples collected from 41 fallow deer with or without histopathological lesions consistent with paratuberculosis. Two target antigenic preparations were selected, an ethanol-treated protoplasmic preparation obtained from a fallow deer M. avium subsp. paratuberculosis isolate (ELISAs A and B) and a paratuberculosis protoplasmic antigen (PPA3) (ELISAs C and D). Fallow deer antibodies bound to the immobilized antigens were detected by using a horseradish peroxidase (HRP)-conjugated anti-fallow deer IgG antibody (ELISAs A and C) or HRP-conjugated protein G (ELISAs B and D). A commercially available assay, ELISA-E, which was designed to detect M. avium subsp. paratuberculosis antibodies in cattle, sheep, and goats, was also tested. Although ELISAs A, C, and E had the same sensitivity (72%), ELISAs A and C were more specific (100%) for detecting fallow deer with lesions consistent with paratuberculosis at necropsy than was the ELISA-E (87.5%). In addition, the ELISA-A was particularly sensitive for detecting fallow deer in the latent stages of infection (62.5%). The antibody responses detected with the ELISA-A correlated with both the severity of enteric lesions and the presence of acid-fast bacteria in gut tissue samples. In summary, our study shows that the ELISA-A can be a cost-effective diagnostic tool for preventing the spread of paratuberculosis among fallow deer populations. PMID:24872517

  18. Low sensitivity and frequent cross-reactions in commercially available antibody detection ELISA assays for Taenia solium cysticercosis.

    PubMed

    Garcia, Hector H; Castillo, Yesenia; Gonzales, Isidro; Bustos, Javier A; Saavedra, Herbert; Jacob, Louis; Del Brutto, Oscar H; Wilkins, Patricia P; Gonzalez, Armando E; Gilman, Robert H

    2018-01-01

    To evaluate the diagnostic performance of two commercially available ELISA kits, Novalisa ® and Ridascreen ® , for the detection of antibodies to Taenia solium, compared to serological diagnosis of neurocysticercosis (NCC) by LLGP-EITB (electro-immunotransfer blot assay using lentil-lectin purified glycoprotein antigens). Archive serum samples from patients with viable NCC (n = 45) or resolved, calcified NCC (n = 45), as well as sera from patients with other cestode parasites (hymenolepiasis, n = 45 and cystic hydatid disease, n = 45), were evaluated for cysticercosis antibody detection using two ELISA kits, Novalisa ® and Ridascreen ® . All NCC samples had previously tested positive, and all samples from heterologous infections were negative on LLGP-EITB for cysticercosis. Positive rates were calculated by kit and sample group and compared between the two kits. Compared to LLGP-EITB, the sensitivity of both ELISA assays to detect specific antibodies in patients with viable NCC was low (44.4% and 22.2%), and for calcified NCC, it was only 6.7% and 4.5%. Sera from patients with cystic hydatid disease were highly cross-reactive in both ELISA assays (38/45, 84.4%; and 25/45, 55.6%). Sera from patients with hymenolepiasis cross-reacted in five cases in one of the assays (11.1%) and in only one sample with the second assay (2.2%). The performance of Novalisa ® and Ridascreen ® was poor. Antibody ELISA detection cannot be recommended for the diagnosis of neurocysticercosis. © 2017 John Wiley & Sons Ltd.

  19. Reliability and clinical utility of Enzyme-linked immunosorbent assay for detection of anti-aminoacyl-tRNA synthetase antibody.

    PubMed

    Abe, Takeo; Tsunoda, Shinichiro; Nishioka, Aki; Azuma, Kouta; Tsuboi, Kazuyuki; Ogita, Chie; Yokoyama, Yuichi; Furukawa, Tetsuya; Maruoka, Momo; Tamura, Masao; Yoshikawa, Takahiro; Saito, Atsushi; Sekiguchi, Masahiro; Azuma, Naoto; Kitano, Masayasu; Matsui, Kiyoshi; Hosono, Yuji; Nakashima, Ran; Ohmura, Koichiro; Mimori, Tsuneyo; Sano, Hajime

    2016-01-01

    Anti-aminoacyl-tRNA synthetase (ARS) antibody is one of the myositis-specific autoantibodies to make a diagnosis of polymyositis (PM) and dermatomyositis (DM). Recently a new enzyme-linked immunosorbent assay (ELISA) kit of concurrently detected anti-ARS antibodies (anti-Jo-1, anti-PL-7, anti-PL-12, anti-EJ and anti-KS) have become to measure in the clinical setting. To evaluate the reliability of this ELISA kit, we measured anti-ARS antibodies in 75 PM and DM patients using by this ELISA assay and compared them with the results by RNA immunoprecipitation assay. Between the measurements of anti-PL-7, anti-PL-12, anti-EJ and anti-KS autoantibodies by ELISA assay and RNA-IP assay, the concordance rate of reproducibility is 95.1% and the positive agreement rate is 90.9% and negative agreement rate is 96.0% and kappa statistic is 0.841. Between the measurements of existing anti-Jo-1 antibody ELISA kit and anti-ARS antibody ELISA kit, the concordance rate of reproducibility is 96.9%, the positive agreement rate is 100%, negative agreement rate is 96.1% and kappa statistic is 0.909. The lung involvement in patients with PM and DM patients are positive of anti-ARS antibodies and anti-melanoma differentiation associated gene5 (MDA5) antibody at a rate around 70%. Then most life-threatening ILD with anti-MDA5 positive clinically amyopathic dermatomyositis patients could be highly guessed when anti-ARS antibodies are negative.

  20. Development of a Digital Microarray with Interferometric Reflectance Imaging

    NASA Astrophysics Data System (ADS)

    Sevenler, Derin

    This dissertation describes a new type of molecular assay for nucleic acids and proteins. We call this technique a digital microarray since it is conceptually similar to conventional fluorescence microarrays, yet it performs enumerative ('digital') counting of the number captured molecules. Digital microarrays are approximately 10,000-fold more sensitive than fluorescence microarrays, yet maintain all of the strengths of the platform including low cost and high multiplexing (i.e., many different tests on the same sample simultaneously). Digital microarrays use gold nanorods to label the captured target molecules. Each gold nanorod on the array is individually detected based on its light scattering, with an interferometric microscopy technique called SP-IRIS. Our optimized high-throughput version of SP-IRIS is able to scan a typical array of 500 spots in less than 10 minutes. Digital DNA microarrays may have utility in applications where sequencing is prohibitively expensive or slow. As an example, we describe a digital microarray assay for gene expression markers of bacterial drug resistance.

  1. Glycoprotein-Based Enzyme-Linked Immunosorbent Assays for Serodiagnosis of Infectious Laryngotracheitis

    PubMed Central

    Kanabagatte Basavarajappa, Mallikarjuna; Song, Haichen; Lamichhane, Chinta

    2015-01-01

    For detection of infectious laryngotracheitis virus (ILTV) antibody, glycoprotein B-, C-, and D-based enzyme-linked immunosorbent assays (B-, C-, and D-ELISAs, respectively) were developed. The B- and D-ELISAs showed enhanced detection of anti-ILTV antibodies in infected chickens compared to that of the commercial ELISA. Furthermore, the D-ELISA was efficient in detecting seroconversion with vectored vaccine, using recombinant Newcastle disease virus (rNDV) expressing glycoprotein D (gD) as the vaccine vector. PMID:25694519

  2. SNAP Assay Technology.

    PubMed

    O'Connor, Thomas P

    2015-12-01

    The most widely used immunoassay configuration is the enzyme-linked immunosorbent assay (ELISA) because the procedure produces highly sensitive and specific results and generally is easy to use. By definition, ELISAs are immunoassays used to detect a substance (typically an antigen or antibody) in which an enzyme is attached (conjugated) to one of the reactants and an enzymatic reaction is used to amplify the signal if the substance is present. Optimized ELISAs include several steps that are performed in sequence using a defined protocol that typically includes application of sample and an enzyme-conjugated antibody or antigen to an immobilized reagent, followed by wash and enzyme reaction steps. The SNAP assay is an in-clinic device that performs each of the ELISA steps in a timed sequential fashion with little consumer interface. The components and mechanical mechanism of the assay device are described. Detailed descriptions of features of the assay, which minimize nonspecific binding and enhance the ability to read results from weak-positive samples, are given. Basic principles used in assays with fundamentally different reaction mechanisms, namely, antigen-detection, antibody-detection, and competitive assays are given. Applications of ELISA technology, which led to the development of several multianalyte SNAP tests capable of testing for up to 6 analytes using a single-sample and a single-SNAP device are described. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

  3. An Automated ELISA Using Recombinant Antigens for Serologic Diagnosis of B Virus Infections in Macaques

    PubMed Central

    Katz, David; Shi, Wei; Patrusheva, Irina; Perelygina, Ludmila; Gowda, Manjunath S; Krug, Peter W; Filfili, Chadi N; Ward, John A; Hilliard, Julia K

    2012-01-01

    B virus (Macacine herpesvirus 1) occurs naturally in macaques and can cause lethal zoonotic infections in humans. Detection of B virus (BV) antibodies in macaques is essential for the development of SPF breeding colonies and for diagnosing infection in macaques that are involved in human exposures. Traditionally, BV infections are monitored for presence of antibodies by ELISA (a screening assay) and western blot analysis (WBA; a confirmatory test). Both tests use lysates of infected cells as antigens. Because WBA often fails to confirm the presence of low-titer serum antibodies detected by ELISA, we examined a recombinant-based ELISA as a potential alternative confirmatory test. We compared a high-throughput ELISA using 384-well plates for simultaneous antibody screening against 4 BV-related, recombinant proteins with the standard ELISA and WBA. The recombinant ELISA results confirmed more ELISA-positive sera than did WBA. The superiority of the recombinant ELISA over WBA was particularly prominent for sera with low (<500 ELISA units) antibody titers. Among low-titer sera, the relative sensitivity of the recombinant ELISA ranged from 36.7% to 45.0% as compared with 3.3% to 10.0% for WBA. In addition, the screening and confirmatory assays can be run simultaneously, providing results more rapidly. We conclude that the recombinant ELISA is an effective replacement for WBA as a confirmatory assay for the evaluation of macaque serum antibodies to BV. PMID:23561887

  4. Image-based ELISA on an activated polypropylene microtest plate--a spectrophotometer-free low cost assay technique.

    PubMed

    Parween, Shahila; Nahar, Pradip

    2013-10-15

    In this communication, we report ELISA technique on an activated polypropylene microtest plate (APPµTP) as an illustrative example of a low cost diagnostic assay. Activated test zone in APPµTP binds a capture biomolecule through covalent linkage thereby, eliminating non-specific binding often prevalent in absorption based techniques. Efficacy of APPµTP is demonstrated by detecting human immunoglobulin G (IgG), human immunoglobulin E (IgE) and Aspergillus fumigatus antibody in patient's sera. Detection is done by taking the image of the assay solution by a desktop scanner and analyzing the color of the image. Human IgE quantification by color saturation in the image-based assay shows excellent correlation with absorbance-based assay (Pearson correlation coefficient, r=0.992). Significance of the relationship is seen from its p value which is 4.087e-11. Performance of APPµTP is also checked with respect to microtiter plate and paper-based ELISA. APPµTP can quantify an analyte as precisely as in microtiter plate with insignificant non-specific binding, a necessary prerequisite for ELISA assay. In contrast, paper-ELISA shows high non-specific binding in control sera (false positive). Finally, we have carried out ELISA steps on APPµTP by ultrasound waves on a sonicator bath and the results show that even in 8 min, it can convincingly differentiate a test sample from a control sample. In short, spectrophotometer-free image-based miniaturized ELISA on APPµTP is precise, reliable, rapid, and sensitive and could be a good substitute for conventional immunoassay procedures widely used in clinical and research laboratories. Copyright © 2013 Elsevier B.V. All rights reserved.

  5. Engineered Antibodies for Monitoring of Polynuclear Aromatic Hydrocarbons

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Alexander E. Karu Ph.D; Victoria A. Roberts Ph.D.; Qing X. Li, Ph.D.

    2002-01-17

    This project was undertaken to fill needs in ODE's human and ecosystem health effects research, site remediation, rapid emergency response, and regulatory compliance monitoring programs. Doe has greatly stimulated development and validation of antibody-based, rapid, field-portable detection systems for small hazardous compounds. These range from simple dipsticks, microplate enzyme-linked immunosorbent assays (ELISAs), and hand-held colorimeters, to ultrasensitive microfluidic reactors, fiber-optic sensors and microarrays that can identify multiple analytes from patterns of cross-reactivity. Unfortunately, the technology to produce antibodies with the most desirable properties did not keep pace. Lack of antibodies remains a limiting factor in production and practical use ofmore » such devices. The goals of our project were to determine the chemical and structural bases for the antibody-analyte binding interactions using advanced computational chemistry, and to use this information to create useful new binding properties through in vitro genetic engineering and combinatorial library methods.« less

  6. Evaluation of the performance of two tuberculosis interferon gamma release assays (IGRA-ELISA and T-SPOT.TB) for diagnosing Mycobacterium tuberculosis infection.

    PubMed

    Wang, Linchuan; Tian, Xu-Dong; Yu, Yan; Chen, Wei

    2018-04-01

    The IGRA-ELISA and T-SPOT.TB are widely used in China. The aim of the study was to evaluate the performance of the two assays in diagnosis Mycobacterium tuberculosis infection. Of the 3727 patients in the study, 204 underwent testing using both the T-SPOT.TB and IGRA-ELISA, 1794 were tested using the T-SPOT.TB only, and 1729 were tested using the IGRA-ELISA only. The positive rate and consistency of the two assays were analyzed, and their sensitivity and specificity for diagnosing active tuberculosis were compared. There were no significant differences in the positive rate between the T-SPOT.TB test (25.8%) and IGRA-ELISA (28.6%), p = .065. The two assays were highly consistent, with a kappa value of 0.852 (p < .0001) and a total coincidence rate of 92.7%. For the diagnosis of active tuberculosis, the sensitivity and specificity values of the T-SPOT.TB test were 82.9% (107/129) and 78.6% (1309/1665), respectively, and those of IGRA-ELISA were 81.7% (94/115) and 75.2% (1214/1614), respectively. There were no significant differences in sensitivity (p > .05), but the specificity of the T-SPOT.TB test was slightly higher than that of IGRA-ELISA (p = .023). Both in terms of diagnosing M. tuberculosis infection and ruling out active tuberculosis, the performance of the IGRA-ELISA-a simple, almost labor-free assay that allows simultaneous processing of a very large number of samples-was well-matched with that of T-SPOT.TB test. However, IGRAs cannot be used as the only test to diagnose active tuberculosis. Copyright © 2018 Elsevier B.V. All rights reserved.

  7. An rK28-Based Immunoenzymatic Assay for the Diagnosis of Canine Visceral Leishmaniasis in Latin America

    PubMed Central

    Lauricella, Marta Alicia; Maidana, Cristina Graciela; Frias, Victoria Fragueiro; Romagosa, Carlo M.; Negri, Vanesa; Benedetti, Ruben; Sinagra, Angel J.; Luna, Concepcion; Tartaglino, Lilian; Laucella, Susana; Reed, Steven G.; Riarte, Adelina R.

    2016-01-01

    Direct observation of Leishmania parasites in tissue aspirates has shown low sensitivity for the detection of canine visceral leishmaniasis (VL). Therefore in the last quarter century immunoenzymatic tests have been developed to improve diagnosis. The purpose of this study was to develop a fast recombinant K28 antigen, naked-eye qualitative enzyme-linked immunosorbent assay (VL Ql-ELISA) and a quantitative version (VL Qt-ELISA), and to display it in a kit format, whose cutoff value (0.156) was selected as the most adequate one to differentiate reactive from nonreactive samples. Considering 167 cases and 300 controls, sensitivity was 91% for both assays and specificity was 100% and 98.7% in Ql-ELISA and Qt-ELISA, respectively. Positive predictive values were 100% and 97.4% for Ql-ELISA and Qt-ELISA, respectively, and negative predictive values were 95.2% for both ELISAs. Reagent stability, reliability studies, including periodic repetitions and retest of samples, cutoff selection, and comparison of rK28 ELISAs with rK39 immunochromatographic test, were the international criteria that supported the quality in both kits. The performance of both ELISA kits in this work confirmed their validity and emphasized their usefulness for low-to-medium complexity laboratories. PMID:27162270

  8. Application of Protein Microarrays for Multiplexed Detection of Antibodies to Tumor Antigens in Breast Cancer

    PubMed Central

    Anderson, Karen S.; Ramachandran, Niroshan; Wong, Jessica; Raphael, Jacob V.; Hainsworth, Eugenie; Demirkan, Gokhan; Cramer, Daniel; Aronzon, Diana; Hodi, F. Stephen; Harris, Lyndsay; Logvinenko, Tanya; LaBaer, Joshua

    2012-01-01

    There is strong preclinical evidence that cancer, including breast cancer, undergoes immune surveillance. This continual monitoring, by both the innate and the adaptive immune systems, recognizes changes in protein expression, mutation, folding, glycosylation, and degradation. Local immune responses to tumor antigens are amplified in draining lymph nodes, and then enter the systemic circulation. The antibody response to tumor antigens, such as p53 protein, are robust, stable, and easily detected in serum, may exist in greater concentrations than their cognate antigens, and are potential highly specific biomarkers for cancer. However, antibodies have limited sensitivities as single analytes, and differences in protein purification and assay characteristics have limited their clinical application. For example, p53 autoantibodies in the sera are highly specific for cancer patients, but are only detected in the sera of 10-20% of patients with breast cancer. Detection of p53 autoantibodies is dependent on tumor burden, p53 mutation, rapidly decreases with effective therapy, but is relatively independent of breast cancer subtype. Although antibodies to hundreds of other tumor antigens have been identified in the sera of breast cancer patients, very little is known about the specificity and clinical impact of the antibody immune repertoire to breast cancer. Recent advances in proteomic technologies have the potential for rapid identification of immune response signatures for breast cancer diagnosis and monitoring. We have adapted programmable protein microarrays for the specific detection of autoantibodies in breast cancer. Here, we present the first demonstration of the application of programmable protein microarray ELISAs for the rapid identification of breast cancer autoantibodies. PMID:18311903

  9. Amplification of the enzyme-linked immunosorbent assay (ELISA) in the detection of class-specific antibodies.

    PubMed

    Butler, J E; McGivern, P L; Swanson, P

    1978-01-01

    A modification of the standard enzyme-linked immunosorbent assay (ELISA) is described which circumvents the requirement for specifically purified antibodies from which antibody-enzyme complexes are made. The assay utilizes the principle of a soluble anti-alkaline phosphatase immune complex (AP-A-AP) and has been called the amplified ELISA. Methods for preparing and evidence for the specificity of rabbit anti-rat gamma-FC, IgM (mu) and IgA (alpha) are presented. These reagents are used to measure anti-DNP antibodies belonging to classes IgG, IgM and IgA in rat serum. Using antiglobulin and anti-enzyme reagents prepared in guinea pigs, anti-ovalbumin antibodies are measured in rabbit serum. Titration curves are similar when the amplified ELISA is compared to the standard ELISA. A change in slope suggesting an effect of saturation of antigen sites, occurs at the same input antibody concentration for both assays. Determination of the anti-DNP concentration of unknown sera by extrapopulation from titration graphs of a known serum suggests that the value is overestimated, i.e., amplified when the amplified ELISA is used. In addition, the amplified ELISA has an improved ability to detect low levels of antibody. Evidence is presented which illustrates how the use of optimally conjugated DNP-proteins, age of conjugates, and optimal dilutions of secondary antiglobulins and the AP-A-AP reduce non-specific binding in the amplified ELISA. The amplified ELISA is capable of detecting 2.4 ng of antibody to ovalbumin in a one: one million dilution of rabbit serum with high reproducibility and low background.

  10. Molecular Approaches for High Throughput Detection and Quantification of Genetically Modified Crops: A Review

    PubMed Central

    Salisu, Ibrahim B.; Shahid, Ahmad A.; Yaqoob, Amina; Ali, Qurban; Bajwa, Kamran S.; Rao, Abdul Q.; Husnain, Tayyab

    2017-01-01

    As long as the genetically modified crops are gaining attention globally, their proper approval and commercialization need accurate and reliable diagnostic methods for the transgenic content. These diagnostic techniques are mainly divided into two major groups, i.e., identification of transgenic (1) DNA and (2) proteins from GMOs and their products. Conventional methods such as PCR (polymerase chain reaction) and enzyme-linked immunosorbent assay (ELISA) were routinely employed for DNA and protein based quantification respectively. Although, these Techniques (PCR and ELISA) are considered as significantly convenient and productive, but there is need for more advance technologies that allow for high throughput detection and the quantification of GM event as the production of more complex GMO is increasing day by day. Therefore, recent approaches like microarray, capillary gel electrophoresis, digital PCR and next generation sequencing are more promising due to their accuracy and precise detection of transgenic contents. The present article is a brief comparative study of all such detection techniques on the basis of their advent, feasibility, accuracy, and cost effectiveness. However, these emerging technologies have a lot to do with detection of a specific event, contamination of different events and determination of fusion as well as stacked gene protein are the critical issues to be addressed in future. PMID:29085378

  11. Evaluation of ethanol vortex ELISA for detection of bovine tuberculosis in cattle and deer

    USDA-ARS?s Scientific Manuscript database

    Background The use of serological assays for diagnosis of bovine tuberculosis (TB) has been intensively studied and use of specific antigens have aided in improving the diagnostic accuracy of the assays. In the present study, we report an in-house enzyme linked immunosorbent assay (ELISA), developed...

  12. International ring trial to detect anti-Trichinella IgG by ELISA on pig sera.

    USDA-ARS?s Scientific Manuscript database

    In the present study, the sensitivity and specificity of the ELISA assay determined by the CRLP validation was 100% and 98.29%, respectively. The assay was reproducible, moreover, based on the receiver-operator characteristic (ROC) curve, the sensitivity and specificity of the assay reached 97.5% an...

  13. Comparison of the performance of IFA, CFA, and ELISA assays for the serodiagnosis of acute Q fever by quality assessment.

    PubMed

    Herremans, Tineke; Hogema, Boris M; Nabuurs, Marrigje; Peeters, Marcel; Wegdam-Blans, Marjolijn; Schneeberger, Peter; Nijhuis, Carla; Notermans, Daan W; Galama, Joep; Horrevorts, Anton; van Loo, Inge H M; Vlaminckx, Bart; Zaaijer, Hans L; Koopmans, Marion P; Berkhout, Hanneke; Socolovschi, Cristina; Raoult, Didier; Stenos, John; Nicholson, William; Bijlmer, Henk

    2013-01-01

    The indirect immunofluorescence assay (IFA) is considered the reference method for diagnosing Q fever, but serology is also performed by complement fixation assay (CFA) or enzyme-linked immunosorbent assay (ELISA). However, comparability between these assays is not clear, and therefore a quality assessment was performed. A total of 25 serum samples from negative controls, Q fever patients, and a serial diluted high-positive sample were analyzed in 10 Dutch laboratories. Six laboratories performed CFA, 5 performed IFA, and 5 performed ELISAs. Three international reference laboratories from Australia, France, and the USA also participated in this study. Qualitative values between laboratories using the same methods were within close range, and all 3 methods correctly identified acute Q fever patients. The IFA, ELISA, and CFA are all suitable serodiagnostic assays to diagnose acute Q fever, but the IFA remains an important tool in the follow-up of patients and in identifying patients at risk for developing chronic Q fever. Copyright © 2013 Elsevier Inc. All rights reserved.

  14. Comparability of the effect of storage time and temperature on serum anti-Müllerian hormone measurement between original and modified enzyme-linked immunosorbent assay.

    PubMed

    Yue, Chao-Yan; Ying, Chun-Mei

    2017-01-01

    To explore the effect of modified enzyme-linked immunosorbent assay on the AMH results is increased or decreased, and to investigate the effect of storage time and temperature on AMH measurements with and without sample premixing assay buffer using the Kangrun ELISA method. Serum AMH concentration were measured by ELISA, consistency between two kits, and comparability between original and the modified assay under different stored conditions were analyzed by Passing-Bablok regression analysis and Bland-Altman bias evaluation. There was a strong consistency between AMH concentrations measured in Kangrun ELISA and Ansh Labs ultra-sensitive AMH ELISA. Pre-mixing serum specimens with assay buffer gave consistent results compared with original assay. Modified protocol can reduce the amplitude of increase affected by sample aged and give the most consistent results regardless of storage conditions. Pre-mixing protocol did not influence the results of fresh serum or frozen serum incubation <3days at 4°C and -80°C, but when specimens detected after collection and stored in other storage conditions, should be pre-mixed with assay buffer to insure its accuracy. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. High Frequency of Chlamydia trachomatis Mixed Infections Detected by Microarray Assay in South American Samples.

    PubMed

    Gallo Vaulet, Lucía; Entrocassi, Carolina; Portu, Ana I; Castro, Erica; Di Bartolomeo, Susana; Ruettger, Anke; Sachse, Konrad; Rodriguez Fermepin, Marcelo

    2016-01-01

    Chlamydia trachomatis is one of the most common sexually transmitted infections worldwide. Based on sequence variation in the ompA gene encoding the major outer membrane protein, the genotyping scheme distinguishes 17 recognized genotypes, i.e. A, B, Ba, C, D, Da, E, F, G, H, I, Ia, J, K, L1, L2, and L3. Genotyping is an important tool for epidemiological tracking of C. trachomatis infections, including the revelation of transmission pathways and association with tissue tropism and pathogenicity. Moreover, genotyping can be useful for clinicians to establish the correct treatment when LGV strains are detected. Recently a microarray assay was described that offers several advantages, such as rapidity, ease of standardization and detection of mixed infections. The aim of this study was to evaluate the performance of the DNA microarray-based assay for C. trachomatis genotyping of clinical samples already typed by PCR-RFLP from South America. The agreement between both typing techniques was 90.05% and the overall genotype distribution obtained with both techniques was similar. Detection of mixed-genotype infections was significantly higher using the microarray assay (8.4% of cases) compared to PCR-RFLP (0.5%). Among 178 samples, the microarray assay identified 10 ompA genotypes, i.e. D, Da, E, F, G, H, I, J, K and L2. The most predominant type was genotype E, followed by D and F.

  16. Development of 316v antibody enzyme-linked immunosorbent assay for detection of paratuberculosis in sheep.

    PubMed

    Gurung, R B; Begg, D J; Purdie, A C; Eamens, G J; Whittington, R J

    2015-12-01

    An enzyme-linked immunosorbent assay (ELISA) was developed and optimised using a Mycobacterium avium subspecies paratuberculosis (MAP) antigen prepared from a C strain (316v) passed through a French press. The optimised assay was evaluated with a panel of sera from MAP infected (n = 66) and uninfected (n = 1,092) sheep. Animals in the MAP infected category were positive on either tissue culture or histopathology but were of unknown serum antibody status. The diagnostic performance and cost of the assay were compared with those of a commercial ELISA (IDEXX). At 99.8% diagnostic specificity the assay showed a diagnostic sensitivity of 23% (95% CI: 15.1-35.8) compared with 36.4% (95% CI: 25.8-48.4) for the commercial ELISA (McNemar's test: chi-square 5.82, p < 0.05). The sensitivities were 5.9% (95% CI: 1-26.9), 27.9% (95% CI: 14.7-45.7) and 35% (95% CI: 18.1-56.7), for low grade, paucibacillary and multibacillary lesion grades, respectively. The cost of the commercial assay kit was 2.7 to 5.2 times greater than that of the 316v ELISA for an equivalent number of tests, the multiple depending on the number of plates processed per run. For flock-level surveillance, to account for the lower sensitivity of the 316v ELISA compared with the commercial ELISA, sample sizes would be increased but the test cost would still be lower. The 316v assay will be useful for diagnosis of Johne's disease in sheep flocks, particularly in developing countries where labour costs are low relative to the cost of consumables.

  17. Exploiting Inhibitory Siglecs to Combat Food Allergies

    DTIC Science & Technology

    2017-10-01

    project including mouse handling, liposome preparation, and in vitro assays, such as ELISAs . Shiteng and Kevin Worrell participated in groups...h 2. She also contributed by running some ELISA experiments. Funding Support: N/A Name: Kelly Orgel Project Role: Graduate Student (UNC...flow cytometry, and ELISA . Kelly performed the human CD33 basophil assays as well. Funding Support: N/A Name: Johanna Smeekens, PhD Project

  18. Development and evaluation of a blocking enzyme-linked immunosorbent assay and virus neutralization assay to detect antibodies to viral hemorrhagic septicemia virus

    USGS Publications Warehouse

    Wilson, Anna; Goldberg, Tony; Marcquenski, Susan; Olson, Wendy; Goetz, Frederick; Hershberger, Paul; Hart, Lucas M.; Toohey-Kurth, Kathy

    2014-01-01

    Viral hemorrhagic septicemia virus (VHSV) is a target of surveillance by many state and federal agencies in the United States. Currently, the detection of VHSV relies on virus isolation, which is lethal to fish and indicates only the current infection status. A serological method is required to ascertain prior exposure. Here, we report two serologic tests for VHSV that are nonlethal, rapid, and species independent, a virus neutralization (VN) assay and a blocking enzyme-linked immunosorbent assay (ELISA). The results show that the VN assay had a specificity of 100% and sensitivity of 42.9%; the anti-nucleocapsid-blocking ELISA detected nonneutralizing VHSV antibodies at a specificity of 88.2% and a sensitivity of 96.4%. The VN assay and ELISA are valuable tools for assessing exposure to VHSV.

  19. Matrix effect and cross-reactivity of select amphetamine-type substances, designer analogues, and putrefactive amines using the Bio-Quant direct ELISA presumptive assays for amphetamine and methamphetamine.

    PubMed

    Apollonio, Luigino G; Whittall, Ian R; Pianca, Dennis J; Kyd, Jennelle M; Maher, William A

    2007-05-01

    The aim of this study was to evaluate the Bio-Quant Direct ELISA assays for amphetamine and methamphetamine in the routine presumptive screening of biological fluids. Standard concentration curves of the target analytes were assayed to assess sensitivity, and known concentrations of common amphetamine-type substances (ephedrine, pseudoephedrine, phentermine), designer analogues (MDA, MDMA, MDEA, MBDB, PMA, 4-MTA, 2CB), and putrefactive amines (phenylethylamine, putrescine, tryptamine, tyramine) were analyzed to determine cross-reactivity. Results of the standard curve studies show the capacity of both Direct ELISA kits to confidently detect down to 3 ng/mL interday (PBS matrix; CVs 6.3-15.5%). Cross-reactivity relative to that of 50 ng/mL preparations of the target compounds demonstrated that the Direct ELISA kit for amphetamine also detected MDA (282%), PMA (265%), 4-MTA (280%), and phentermine (61%), and the Direct ELISA for methamphetamine also assayed positive for MDMA (73%), MDEA (18%), pseudoephedrine (19%), MBDB (8%), and ephedrine (9%). Matrix studies demonstrated that both ELISA kits could be applied to screening of blood, urine, and saliva to a concentration of 6 ng/mL or lower. In conclusion, the Bio-Quant Direct ELISA kits for amphetamine and methamphetamine are fast and accurate and have demonstrated themselves to be useful tools in routine toxicological testing.

  20. Functional expression of BMP7 receptors in oral epithelial cells. Interleukin-17F production in response to BMP7.

    PubMed

    Nishio, Kensuke; Ozawa, Yasumasa; Ito, Hisanori; Kifune, Takashi; Narita, Tatsuya; Iinuma, Toshimitsu; Gionhaku, Nobuhito; Asano, Masatake

    2017-10-01

    Bone morphogenetic proteins (BMPs) are members of the transforming growth factor-β (TGF-β) superfamily. Recently, BMP7 has been demonstrated to be produced by salivary glands and contribute to embryonic branching in mice. The BMP7 in saliva is thought to be delivered to the oral cavity and is expected to contact with stratified squamous epithelial cells which line the surface of oral mucosa. In this study, we attempted to investigate the effects of BMP7 on oral epithelial cells. The expression of BMP receptors was examined by reverse transcriptase-polymerase chain reaction (RT-PCR). OSCCs were stimulated with human recombinant BMP7 (hrBMP7) and the phosphorylation status of Smad1/5/8 was examined by western blotting. For microarray analysis, Ca9-22 cells were stimulated with 100 ng/mL of hrBMP7 and total RNA was extracted and subjected to real-time PCR. The 5'-untranslated region (5'-UTR) of IL-17 F gene was cloned to pGL4-basic vector and used for luciferase assay. Ca9-22 cells were pre-incubated with DM3189, a specific inhibitor of Smad1/5/8, for inhibition assay. All isoforms of type I and type II BMP receptors were expressed in both Ca9-22 and HSC3 cells and BMP7 stimulation resulted in the phosphorylation of Smad1/5/8 in both cell lines. The microarray analysis revealed the induction of interleukin-17 F (IL-17 F), netrin G2 (NTNG2) and hyaluronan synthase 1 (HAS1). Luciferase assay using the 5'-UTR of the IL-17 F gene revealed transcriptional regulation. Induced IL-17 F production was further confirmed at the protein level by ELISA. Smad1/5/8 inhibitor pretreatment decreased IL-17 F expression levels in the cells.

  1. Moderate reagent mixing on an orbital shaker reduces the incubation time of enzyme-linked immunosorbent assay.

    PubMed

    Kumar, Saroj; Ahirwar, Rajesh; Rehman, Ishita; Nahar, Pradip

    2017-07-01

    Rapid diagnostic tests can be developed using ELISA for detection of diseases in emergency conditions. Conventional ELISA takes 1-2 days, making it unsuitable for rapid diagnostics. Here, we report the effect of reagents mixing via shaking or vortexing on the assay timing of ELISA. A 48-min protocol of ELISA involving 12-min incubations with reagent mixing at 750 rpm for every step was optimized. Contrary to this, time-optimized control ELISA performed without mixing produced similar results in 8 h, leaving a time gain of 7 h using the developed protocol. Collectively, the findings suggest the development of ELISA-based rapid diagnostics. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Evaluation of Chicken IgY Generated Against Canine Parvovirus Viral-Like Particles and Development of Enzyme-Linked Immunosorbent Assay and Immunochromatographic Assay for Canine Parvovirus Detection.

    PubMed

    He, Jinxin; Wang, Yuan; Sun, Shiqi; Zhang, Xiaoying

    2015-11-01

    Immunoglobulin Y (IgY) antibodies were generated against canine parvovirus virus-like particles (CPV-VLPs) antigen using chickens. Anti-CPV-VLPs-IgY was extracted from hen egg yolk and used for developing enzyme-linked immunosorbent assay (ELISA) and immunochromatographic assay (ICA) for the detection of CPV in dog feces. The cutoff negative values for anti-CPV-VLPs-IgY were determined using negative fecal samples (already confirmed by polymerase chain reaction [PCR]). In both ELISA and ICA, there was no cross-reaction with other diarrheal pathogens. Thirty-four fecal samples were collected from dogs with diarrhea, of which 26.47% were confirmed as CPV-positive samples by PCR, while 29.41% and 32.35% of the samples were found to be positive by ELISA and ICA, respectively. The developed ELISA and ICA exhibited 97.06% and 94.12% conformity with PCR. Higher sensitivity and specificity were observed for IgY-based ELISA and ICA. Thus, they could be suitable for routine use in the diagnosis of CPV in dogs.

  3. Combining two serological assays optimises sensitivity and specificity for the identification of Streptococcus equi subsp. equi exposure.

    PubMed

    Robinson, Carl; Steward, Karen F; Potts, Nicola; Barker, Colin; Hammond, Toni-ann; Pierce, Karen; Gunnarsson, Eggert; Svansson, Vilhjálmur; Slater, Josh; Newton, J Richard; Waller, Andrew S

    2013-08-01

    The detection of anti-Streptococcus equi antibodies in the blood serum of horses can assist with the identification of apparently healthy persistently infected carriers and the prevention of strangles outbreaks. The aim of the current study was to use genome sequencing data to develop an indirect enzyme linked immunosorbent assay (iELISA) that targets two S. equi-specific protein fragments. The sensitivity and specificity of the antigen A and antigen C iELISAs were compared to an SeM-based iELISA marketed by IDvet - diagnostic Vétérinaire (IDvet). Individually, each assay compromised specificity in order to achieve sufficient sensitivity (SeM iELISA had a sensitivity of 89.9%, but a specificity of only 77.0%) or sensitivity to achieve high specificity. However, combining the results of the antigen A and antigen C iELISAs permitted optimisation of both sensitivity (93.3%) and specificity (99.3%), providing a robust assay for the identification of horses exposed to S. equi. Copyright © 2013 Elsevier Ltd. All rights reserved.

  4. Comparisons of VLP-Based ELISA, Neutralization Assays with Native HPV, and Neutralization Assays with PsV in Detecting HPV Antibody Responses in HIV-Infected Women

    PubMed Central

    Du, Ping; Brendle, Sarah; Milici, Janice; Camacho, Fabian; Zurlo, John; Christensen, Neil; Meyers, Craig

    2015-01-01

    Objective Human papillomavirus (HPV)-associated cancers are important public health problems in HIV-infected people. Assays based on HPV virus-like particles (VLP) and pseudoviruses (PsV) are commonly used to examine HPV antibody responses in HIV-infected people, but neutralization assays with native HPV have not been utilized and a comparison of these three assays is lacking. We evaluated the agreement of assays using VLP, native HPV and PsV in detecting HPV16 and 18 antibodies in HIV-infected women. Methods The VLP-based ELISA (VLP-ELISA) was used to detect antibody responses to HPV16 and 18 and cottontail rabbit papillomavirus (CRPV) VLP antigens. Neutralization assays with native HPV (NA-HPV) and with PsV (NA-PsV) were conducted to examine HPV16 or 18 neutralizing antibodies. Intra class correlation coefficients (ICC) and kappa coefficients were used to assess the agreements of seropositivity between the assays. Results The seroprevalence detected by the VLP-ELISA, NA-HPV and NA-PsV in 94 HIV-infected women was 35%, 51% and 27% for HPV16 and 14%, 44% and 21% for HPV18. Cross-reactivity between HPV16 and HPV18 was 0.35, 0.04 and 0.33 (kappa coefficients) for the VLP-ELISA, NA-HPV and NA-PsV. The agreements of seropositivity between the three assays were low. Six women who were HPV16 DNA positive were seropositive by the NA-HPV but only two were HPV16 seropositive by the VLP-ELISA or NA-PsV. One HPV18 DNA positive woman was seropositive by all three assays. Repeated tests indicated excellent reproducibility of the NA-HPV. Conclusion HPV serology results vary across different assays. The NA-HPV appears to be a sensitive and reliable approach in detecting natural HPV antibodies in HIV-infected women. The NA-HPV can be applied in both HPV natural history studies and vaccine studies in HIV-infected people. PMID:26085957

  5. Comparability of ELISA and toxin neutralization to measure immunogenicity of Protective Antigen in mice, as part of a potency test for anthrax vaccines.

    PubMed

    Parreiras, P M; Sirota, L A; Wagner, L D; Menzies, S L; Arciniega, J L

    2009-07-16

    Complexities of lethal challenge models have prompted the investigation of immunogenicity assays as potency tests of anthrax vaccines. An ELISA and a lethal toxin neutralization assay (TNA) were used to measure antibody response to Protective Antigen (PA) in mice immunized once with either a commercial or a recombinant PA (rPA) vaccine formulated in-house. Even though ELISA and TNA results showed correlation, ELISA results may not be able to accurately predict TNA results in this single immunization model.

  6. Glycoprotein-based enzyme-linked immunosorbent assays for serodiagnosis of infectious laryngotracheitis.

    PubMed

    Kanabagatte Basavarajappa, Mallikarjuna; Song, Haichen; Lamichhane, Chinta; Samal, Siba K

    2015-05-01

    For detection of infectious laryngotracheitis virus (ILTV) antibody, glycoprotein B-, C-, and D-based enzyme-linked immunosorbent assays (B-, C-, and D-ELISAs, respectively) were developed. The B- and D-ELISAs showed enhanced detection of anti-ILTV antibodies in infected chickens compared to that of the commercial ELISA. Furthermore, the D-ELISA was efficient in detecting seroconversion with vectored vaccine, using recombinant Newcastle disease virus (rNDV) expressing glycoprotein D (gD) as the vaccine vector. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  7. Development of a Multianalyte Enzyme-Linked Immunosorbent Assay for Permethrin and Aroclors and Its Implementation for Analysis of Soil/Sediment and House Dust ExtractsExtracts

    EPA Science Inventory

    Development of a multianalyte enzyme-linked immunosorbent assay (ELISA) for detection of permethrin and aroclors 1248 or 1254, and implementation of the assay for analysis of soil/sediment samples are described. The feasibility of using the multianalyte ELISA to monitor aroclors ...

  8. Development and evaluation of ELISA and qRT-PCR for identification of Squash vein yellowing virus in cucurbits

    USDA-ARS?s Scientific Manuscript database

    Enzyme linked-immunosorbent assay (ELISA) and quantitative reverse transcription-PCR (qRT-PCR) assays were developed for identification of Squash vein yellowing virus (SqVYV), the cause of viral watermelon vine decline. Both assays were capable of detecting SqVYV in a wide range of cucurbit hosts. ...

  9. Competitive and indirect enzyme-linked immunosorbent assays for Mycobacterium bovis infections based on MPB70 and lipoarabinomannan antigens.

    PubMed Central

    Sugden, E A; Stilwell, K; Rohonczy, E B; Martineau, P

    1997-01-01

    A competitive enzyme-linked immunosorbent assay (C-ELISA) using M. bovis BCG Tokyo culture filtrate as antigen and anti-MPB70 4C3/17 monoclonal antibody was developed for use in multiple animal species. An analysis of the C-ELISA data for cattle and bison serum panels revealed specificities of 68% to 85% and sensitivities of 85% to 89%. Receiver operator characteristics (ROC) of this data revealed areas of 81% to 92% for C-ELISA and demonstrated that C-ELISA as well as the indirect ELISA protocols, MPB70-ELISA and LAM-ELISA, discriminate M. bovis infected animals from non-infected animals for these particular panels. The kappa statistic values for agreement beyond chance between C-ELISA and MPB70-ELISA were determined after ELISA cutoffs were adjusted to minimize false positives. There were poor to excellent agreements between C-ELISA and MPB70-ELISA in all species tested (Bovidae, Cervidae, and Camelidae) that were consistently higher than the kappa statistic between C-ELISA and LAM-ELISA. The humoral response to one antigen and little or no response to the other in many animals argued for a parallel interpretation of C-ELISA and LAM-ELISA to increase sensitivity. PMID:9008794

  10. Performance evaluation of FlowCytomix assays to quantify cytokines in patients with rheumatoid arthritis

    PubMed Central

    Wang, Xuefeng; Dong, Liyang; Liang, Yong; Ni, Hongchang; Tang, Jun; Xu, Chengcheng; Zhou, Yuepeng; Su, Yuting; Wang, Jun; Chen, Deyu; Mao, Chaoming

    2015-01-01

    Objectives: To compare the cytokine profile in RA patients and healthy control by using two methods-FlowCytomix assay and traditional ELISA. Methods: Cytokine levels were evaluated by FlowCytomix assay and ELISA in serum and supernatants of peripheral blood mononuclear cells (PBMC) cultures with and without stimulation by phytohaemagglutinin (PHA). Results: The levels of IL-6, IL-1β, and TNF-α were significantly higher in sera of RA patients than those of healthy controls. The levels of IL-22, IL-6, IL-1β, TNF-α, and IL-10 were higher in unstimulated PBMC culture supernatant of RA patients than those of healthy controls. PHA stimulation significantly increased the production of proinflammatory cytokines from PBMC with RA patients. Compared with detectable cytokine levels in sera, cytokine concentration in the supernatant of PBMCs was remarkably higher. FlowCytomix and ELISA showed significant correlation in detecting cytokines. However, the FlowCytomix assay detected more cytokines than ELISA. Conclusion: The supernatant of PBMCs provide a fine condition for the study of cytokine production because of the lack of interference factors in sera. The FlowCytomix assay is more sensitive than ELISA in detecting cytokines from RA patients. Multiple cytokine signatures using FlowCytomix assay may represent a more realistic approach in the future of personalized medicine in RA. PMID:26629129

  11. Validation of 2 commercial Neospora caninum antibody enzyme linked immunosorbent assays

    PubMed Central

    Wu, John T.Y.; Dreger, Sally; Chow, Eva Y.W.; Bowlby, Evelyn E.

    2002-01-01

    Abstract This is a validation study of 2 commercially available enzyme linked immunosorbent assays (ELISA) for the detection of antibodies against Neospora caninum in bovine serum. The results of the reference sera (n = 30) and field sera from an infected beef herd (n = 150) were tested by both ELISAs and the results were compared statistically. When the immunoblotting results of the reference bovine sera were compared to the ELISA results, the same identity score (96.67%) and kappa values (K) (0.93) were obtained for both ELISAs. The sensitivity and specificity values for the IDEXX test were 100% and 93.33% respectively. For the Biovet test 93.33% and 100% were obtained. The corresponding positive (PV+) and negative predictive (PV−) values for the 2 assays were 93.75% and 100% (IDEXX), and 100% and 93.75% (Biovet). In the 2nd study, competitive inhibition ELISA (c-ELISA) results on bovine sera from an infected herd were compared to the 2 sets of ELISA results. The identity scores of the 2 ELISAs were 98% (IDEXX) and 97.33% (Biovet). The K values calculated were 0.96 (IDEXX) and 0.95 (Biovet). For the IDEXX test the sensitivity and specificity were 97.56% and 98.53%, whereas for the Biovet assay 95.12% and 100% were recorded, respectively. The corresponding PV+ and PV− values were 98.77% and 97.1% (IDEXX), and 100% and 94.44% (Biovet). Our validation results showed that the 2 ELISAs worked equally well and there was no statistically significant difference between the performance of the 2 tests. Both tests showed high reproducibility, repeatability and substantial agreement with results from 2 other laboratories. A quality assurance based on the requirement of the ISO/IEC 17025 standards has been adopted throughout this project for test validation procedures. PMID:12418782

  12. Comparison of Three Enzyme-Linked Immunosorbent Assays for Detection of Immunoglobulin G Antibodies to Tetanus Toxoid with Reference Standards and the Impact on Clinical Practice▿

    PubMed Central

    van Hoeven, Karen H.; Dale, Connie; Foster, Phil; Body, Barbara

    2008-01-01

    Accurate determination of the concentrations of immunoglobulin G (IgG) antibody to tetanus toxoid is important in order to evaluate the immunogenicity of tetanus toxoid vaccines, determine immune competence in individual patients, and measure the prevalence of immunity in populations. The performance of three commercially available enzyme-linked immunosorbent assays (ELISAs) for IgG antibodies to tetanus toxoid were evaluated. Serially diluted NIBSC 76/589 and TE-3 human tetanus IgG immunoglobulin international reference standards were analyzed in quadruplicate using ELISAs manufactured by The Binding Site, Inc. (VaccZyme); Scimedx; and Euroimmun. In addition, IgG antibodies to tetanus toxoid were measured in 83 deidentified serum specimens using each manufacturer's ELISA. Each ELISA provided linear results when evaluated with the reference preparations. The Binding Site ELISA provided results that closely corresponded to the reference preparations (y = 1.09x − 0.08), whereas the Scimedx ELISA gave results that were consistently lower (y = 0.21x − 0.07) and the Euroimmun ELISA gave results that were consistently higher (y = 1.5x + 0.30) than the reference preparation concentrations. Using the recommended cutoff for each ELISA (<0.10 IU/ml), the overall agreement of all of the ELISA methods was 78%. Three of eighty-three (3.6%) human serum samples demonstrated inadequate immunity with all three assays. The Binding Site ELISA yielded nonprotective antibody concentrations in only these 3 samples, whereas 19 samples (22.9%) according to the Scimedx ELISA and 6 samples (7.2%) according to the Euroimmun ELISA demonstrated nonprotective concentrations. The performance characteristics of ELISAs for tetanus immunoglobulin titers were manufacturer dependent, and the differences translated into important disparities in reported results. PMID:18845832

  13. Wnt modulates MCL1 to control cell survival in triple negative breast cancer

    PubMed Central

    2014-01-01

    Background Triple negative breast cancer (TNBC) has higher rates of recurrence and distant metastasis, and poorer outcome as compared to non-TNBC. Aberrant activation of WNT signaling has been detected in TNBC, which might be important for triggering oncogenic conversion of breast epithelial cell. Therefore, we directed our focus on identifying the WNT ligand and its underlying mechanism in TNBC cells. Methods We performed large-scale analysis of public microarray data to screen the WNT ligands and the clinical significance of the responsible ligand in TNBC. WNT5B was identified and its overexpression in TNBC was confirmed by immunohistochemistry staining, Western blot and ELISA. ShRNA was used to knockdown WNT5B expression (shWNT5B). Cellular functional alteration with shWNT5B treatment was determined by using wound healing assay, mammosphere assay; while cell cycle and apoptosis were examined by flowcytometry. Mitochondrial morphology was photographed by electron microscope. Biological change of mitochondria was detected by RT-PCR and oxygen consumption assay. Activation of WNT pathway and its downstream targets were evaluated by liciferase assay, immunohistochemistry staining and immunoblot analysis. Statistical methods used in the experiments besides microarray analysis was two-tailed t-test. Results WNT5B was elevated both in the tumor and the patients’ serum. Suppression of WNT5B remarkably impaired cell growth, migration and mammosphere formation. Additionally, G0/G1 cell cycle arrest and caspase-independent apoptosis was observed. Study of the possible mechanism indicated that these effects occurred through suppression of mitochondrial biogenesis, as evidenced by reduced mitochondrial DNA (MtDNA) and compromised oxidative phosphorylation (OXPHOS). In Vivo and in vitro data uncovered that WNT5B modulated mitochondrial physiology was mediated by MCL1, which was regulated by WNT/β-catenin responsive gene, Myc. Clinic data analysis revealed that both WNT5B and MCL1 are associated with enhanced metastasis and decreased disease-free survival. Conclusions All our findings suggested that WNT5B/MCL1 cascade is critical for TNBC and understanding its regulatory apparatus provided valuable insight into the pathogenesis of the tumor development and the guidance for targeting therapeutics. PMID:24564888

  14. Serum biomarkers of Burkholderia mallei infection elucidated by proteomic imaging of skin and lung abscesses.

    PubMed

    Glaros, Trevor G; Blancett, Candace D; Bell, Todd M; Natesan, Mohan; Ulrich, Robert G

    2015-01-01

    The bacterium Burkholderia mallei is the etiological agent of glanders, a highly contagious, often fatal zoonotic infectious disease that is also a biodefense concern. Clinical laboratory assays that analyze blood or other biological fluids are the highest priority because these specimens can be collected with minimal risk to the patient. However, progress in developing sensitive assays for monitoring B. mallei infection is hampered by a shortage of useful biomarkers. Reasoning that there should be a strong correlation between the proteomes of infected tissues and circulating serum, we employed imaging mass spectrometry (IMS) of thin-sectioned tissues from Chlorocebus aethiops (African green) monkeys infected with B. mallei to localize host and pathogen proteins that were associated with abscesses. Using laser-capture microdissection of specific regions identified by IMS and histology within the tissue sections, a more extensive proteomic analysis was performed by a technique that combined the physical separation capabilities of liquid chromatography (LC) with the sensitive mass analysis capabilities of mass spectrometry (LC-MS/MS). By examining standard formalin-fixed, paraffin-embedded tissue sections, this strategy resulted in the identification of several proteins that were associated with lung and skin abscesses, including the host protein calprotectin and the pathogen protein GroEL. Elevated levels of calprotectin detected by ELISA and antibody responses to GroEL, measured by a microarray of the bacterial proteome, were subsequently detected in the sera of C. aethiops, Macaca mulatta, and Macaca fascicularis primates infected with B. mallei. Our results demonstrate that a combination of multidimensional MS analysis of traditional histology specimens with high-content protein microarrays can be used to discover lead pairs of host-pathogen biomarkers of infection that are identifiable in biological fluids.

  15. Cross-validation of commercial enzyme-linked immunosorbent assay and radioimmunoassay for porcine C-peptide concentration measurements in non-human primate serum.

    PubMed

    Gresch, Sarah C; Mutch, Lucas A; Janecek, Jody L; Hegstad-Davies, Rebecca L; Graham, Melanie L

    2017-09-01

    C-peptide concentration is widely used as a marker of insulin secretion and is especially relevant in evaluating islet graft function following transplantation, because its measurement is not confounded by the presence of exogenous insulin. To address the shortage of human islet donors, the use of porcine islets has been proposed as a possible solution and the stringent pig-to-non-human primate (NHP) model is often the most relevant for pre-clinical evaluation of the potential for diabetes reversal resulting from an islet xenograft. The Millipore radioimmunoassay (RIA) was exclusively used to measure porcine C-peptide (PCP) until 2013 when the assay was discontinued and subsequently a commercially available enzyme-linked immunosorbent assay (ELISA) from Mercodia has been widely adopted. Both assays have been used in pre-clinical trials evaluating the therapeutic potential of xenograft products in reversing diabetes in the pig-to-NHP model, to interpret data in a comparable way it may be useful to perform a harmonization of C-peptide measurements. We performed a method comparison by determining the PCP concentration in 620 serum samples collected from 20 diabetic cynomolgus macaques transplanted with adult porcine islets. All analyses were performed according to manufacturer instructions. With both assays, we demonstrated an acceptable detection limit, precision, and recovery. Linearity of the ELISA met acceptance criteria at all concentrations tested while linearity of the RIA only met acceptance criteria at five of the eight concentrations tested. The RIA had a detection limit of 0.16 ng/mL, and recovery ranged from 82% to 96% and met linearity acceptance criteria at 0.35 ng/mL and from 0.78 to 2.33 ng/mL. The ELISA had a detection limit of 0.03 ng/mL, and recovery ranged from 81% to 115% and met linearity acceptance criteria from 0.08 to 0.85 ng/mL. Both assays had intra-assay precision <11% and inter-assay precision <14%. PCP concentration measured by ELISA demonstrated a significant correlation with RIA (R 2 =.9721, P<.0001). This strong correlation supports use of the regression equation y=2.029x+0.0897 to transform ELISA data to RIA or inversely y=0.4930x-0.0456 to convert RIA data to ELISA for direct comparison between assays in the concentration range of 0-3.0 ng/mL. Measured C-peptide concentration was lower with the ELISA than with the RIA; individual measurements plotted against the averages of the pair demonstrated that the variability from the mean strongly depended on increasing concentration. Porcine C-peptide can be reliably measured in NHP serum using the Mercodia ELISA, making this assay interchangeable with the Millipore RIA. Inherent differences in antibody affinity and calibration factors may explain the lower ELISA values as compared to the RIA; however without access to a traceable reference standard, it is not possible to determine which assay is most accurate. Regression modeling resulted in a correction factor appropriate for conversion of ELISA data to RIA-equivalent data facilitating comparison of assay results longitudinally and between groups. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  16. Novel calibration tools and validation concepts for microarray-based platforms used in molecular diagnostics and food safety control.

    PubMed

    Brunner, C; Hoffmann, K; Thiele, T; Schedler, U; Jehle, H; Resch-Genger, U

    2015-04-01

    Commercial platforms consisting of ready-to-use microarrays printed with target-specific DNA probes, a microarray scanner, and software for data analysis are available for different applications in medical diagnostics and food analysis, detecting, e.g., viral and bacteriological DNA sequences. The transfer of these tools from basic research to routine analysis, their broad acceptance in regulated areas, and their use in medical practice requires suitable calibration tools for regular control of instrument performance in addition to internal assay controls. Here, we present the development of a novel assay-adapted calibration slide for a commercialized DNA-based assay platform, consisting of precisely arranged fluorescent areas of various intensities obtained by incorporating different concentrations of a "green" dye and a "red" dye in a polymer matrix. These dyes present "Cy3" and "Cy5" analogues with improved photostability, chosen based upon their spectroscopic properties closely matching those of common labels for the green and red channel of microarray scanners. This simple tool allows to efficiently and regularly assess and control the performance of the microarray scanner provided with the biochip platform and to compare different scanners. It will be eventually used as fluorescence intensity scale for referencing of assays results and to enhance the overall comparability of diagnostic tests.

  17. Influenza A virus H5-specific antibodies in mute swans (Cygnus olor) in the USA.

    PubMed

    Kistler, Whitney M; Stallknecht, David E; Lebarbenchon, Camille; Pedersen, Kerri; Marks, David R; Mickley, Randy; DeLiberto, Thomas J; Yabsley, Michael J

    2015-04-01

    The use of serologic assays for influenza A virus (IAV) surveillance in wild birds has increased because of the availability of commercial enzyme-linked immunosorbent assays (ELISAs). Recently, an H5-specific blocking ELISA (bELISA) was shown to reliably detect H5-specific antibodies to low- and high-pathogenic H5 viruses in experimentally infected waterfowl. Mute Swans (Cygnus olor) were frequently associated with highly pathogenic H5N1 outbreaks in Europe and may have a similar role if highly pathogenic H5N1 is introduced into North America. We measured the prevalence of antibodies to the nucleoprotein and H5 protein in Mute Swans using three serologic assays. We collected 340 serum samples from Mute Swans in Michigan, New Jersey, New York, and Rhode Island, US. We detected antibodies to the IAV nucleoprotein in 66.2% (225/340) of the samples. We detected H5-specific antibodies in 62.9% (214/340) and 18.8% (64/340) using a modified H5 bELISA protocol and hemagglutination inhibition (HI) assay, respectively. The modified H5 bELISA protocol detected significantly more positive samples than did the manufacturer's protocol. We also tested 46 samples using virus neutralization. Neutralization results had high agreement with the modified H5 bELISA protocol and detected a higher prevalence than did the HI assay. These results indicate that North American Mute Swans have high nucleoprotein and H5 antibody prevalences.

  18. Desomorphine Screening Using Commercial Enzyme-Linked Immunosorbent Assays.

    PubMed

    Winborn, Jessica; Kerrigan, Sarah

    2017-06-01

    Desomorphine ("Krokodil") is a semi-synthetic opioid that has drawn attention as a recreational drug, particularly in Russia, neighboring former Soviet Republics, Eastern and Central Europe. It has no accepted medicinal uses and is currently a schedule I drug in the United States. In clandestine environments, desomorphine is synthesized from codeine using red phosphorous, hydroiodic acid and gasoline. Residual starting materials in illicit preparations have been associated with severe dermatological effects and extensive tissue necrosis. Desomorphine is not well studied, and there are limited reports concerning its pharmacology or detection in biological matrices. Immunoassays are widely relied upon for both antemortem and postmortem toxicology screening. Although desomorphine is an opioid of the phenanthrene-type, its ability to bind to conventional opioid antibodies has not been described. In this report we describe the cross-reactivity of desomorphine using six commercially available enzyme-linked immunosorbent assays (Immunalysis Opiates Direct ELISA, Immunalysis Oxycodone/Oxymorphone Direct ELISA, Randox Opiate ELISA, OraSure Technologies OTI Opiate Micro-plate EIA, Neogen Opiate Group ELISA and Neogen Oxycodone/Oxymorphone ELISA). Cross-reactivites were highly variable between assays, ranging from 77 to <2.5%. In general, assays directed towards morphine produced greater cross-reactivity with desomorphine than those directed towards oxycodone. The Immunalysis Opiates Direct ELISA produced the greatest cross-reactivity, although several of the assays evaluated produced cross-reactivity of a sufficient magnitude to be effective for desomorphine screening. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  19. Sandwich enzyme-linked immunosorbent assay for naringin.

    PubMed

    Qu, Huihua; Wang, Xueqian; Qu, Baoping; Kong, Hui; Zhang, Yue; Shan, Wenchao; Cheng, Jinjun; Wang, Qingguo; Zhao, Yan

    2016-01-15

    Among the currently used immunoassay techniques, sandwich ELISA exhibits higher specificity, lower cross-reactivity, and a wider working range compared to the corresponding competitive assays. However, it is difficult to obtain a pair of antibodies that can simultaneously bind to two epitopes of a molecule with a molecular weight of less than 1000 Da. Naringin (Nar) is a flavonoid with a molecular mass of 580 Da. The main aim of this study was to develop a sandwich ELISA for detecting Nar. Two hybridomas secreting anti-Nar monoclonal antibodies (mAbs) were produced by fusing splenocytes from a mouse immunised against Nar-bovine serum albumin (BSA) conjugated with a hypoxanthine-aminopterin-thymidine (HAT)-sensitive mouse myeloma cell line; a sandwich ELISA for detecting Nar was developed using these two well-characterised anti-Nar mAbs. The performance of the sandwich assay was further evaluated by limit of detection (LOD), limit of quantification (LOQ), recovery, and interference analyses. A dose-response curve to Nar was obtained with an LOD of 6.78 ng mL(-1) and an LOQ of 13.47 ng mL(-1). The inter-assay and intra-assay coefficients of variation were 4.32% and 7.48%, respectively. The recovery rate of Nar from concentrated Fructus aurantii granules was 83.63%. A high correlation was obtained between HPLC and sandwich ELISA. These results demonstrate that the sandwich ELISA method has higher specificity for Nar than indirect competitive ELISA. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. Development and validation of a Luminex assay for detection of a predictive biomarker for PROSTVAC-VF therapy

    PubMed Central

    Lucas, Julie L.; Tacheny, Erin A.; Ferris, Allison; Galusha, Michelle; Srivastava, Apurva K.; Ganguly, Aniruddha; Williams, P. Mickey; Sachs, Michael C.; Thurin, Magdalena; Tricoli, James V.; Ricker, Winnie; Gildersleeve, Jeffrey C.

    2017-01-01

    Cancer therapies can provide substantially improved survival in some patients while other seemingly similar patients receive little or no benefit. Strategies to identify patients likely to respond well to a given therapy could significantly improve health care outcomes by maximizing clinical benefits while reducing toxicities and adverse effects. Using a glycan microarray assay, we recently reported that pretreatment serum levels of IgM specific to blood group A trisaccharide (BG-Atri) correlate positively with overall survival of cancer patients on PROSTVAC-VF therapy. The results suggested anti-BG-Atri IgM measured prior to treatment could serve as a biomarker for identifying patients likely to benefit from PROSTVAC-VF. For continued development and clinical application of serum IgM specific to BG-Atri as a predictive biomarker, a clinical assay was needed. In this study, we developed and validated a Luminex-based clinical assay for measuring serum IgM specific to BG-Atri. IgM levels were measured with the Luminex assay and compared to levels measured using the microarray for 126 healthy individuals and 77 prostate cancer patients. This assay provided reproducible and consistent results with low %CVs, and tolerance ranges were established for the assay. IgM levels measured using the Luminex assay were found to be highly correlated to the microarray results with R values of 0.93–0.95. This assay is a Laboratory Developed Test (LDT) and is suitable for evaluating thousands of serum samples in CLIA certified laboratories that have validated the assay. In addition, the study demonstrates that discoveries made using neoglycoprotein-based microarrays can be readily migrated to a clinical assay. PMID:28771597

  1. Development and Evaluation of a Blocking Enzyme-Linked Immunosorbent Assay and Virus Neutralization Assay To Detect Antibodies to Viral Hemorrhagic Septicemia Virus

    PubMed Central

    Wilson, Anna; Goldberg, Tony; Marcquenski, Susan; Olson, Wendy; Goetz, Frederick; Hershberger, Paul; Hart, Lucas

    2014-01-01

    Viral hemorrhagic septicemia virus (VHSV) is a target of surveillance by many state and federal agencies in the United States. Currently, the detection of VHSV relies on virus isolation, which is lethal to fish and indicates only the current infection status. A serological method is required to ascertain prior exposure. Here, we report two serologic tests for VHSV that are nonlethal, rapid, and species independent, a virus neutralization (VN) assay and a blocking enzyme-linked immunosorbent assay (ELISA). The results show that the VN assay had a specificity of 100% and sensitivity of 42.9%; the anti-nucleocapsid-blocking ELISA detected nonneutralizing VHSV antibodies at a specificity of 88.2% and a sensitivity of 96.4%. The VN assay and ELISA are valuable tools for assessing exposure to VHSV. PMID:24429071

  2. Design of a compact disk-like microfluidic platform for enzyme-linked immunosorbent assay.

    PubMed

    Lai, Siyi; Wang, Shengnian; Luo, Jun; Lee, L James; Yang, Shang-Tian; Madou, Marc J

    2004-04-01

    This paper presents an integrated microfluidic device on a compact disk (CD) that performs an enzyme-linked immunosorbent assay (ELISA) for rat IgG from a hybridoma cell culture. Centrifugal and capillary forces were used to control the flow sequence of different solutions involved in the ELISA process. The microfluidic device was fabricated on a plastic CD. Each step of the ELISA process was carried out automatically by controlling the rotation speed of the CD. The work on analysis of rat IgG from hybridoma culture showed that the microchip-based ELISA has the same detection range as the conventional method on the 96-well microtiter plate but has advantages such as less reagent consumption and shorter assay time over the conventional method.

  3. Biotin avidin amplified magnetic immunoassay for hepatitis B surface antigen detection using GoldMag nanoparticles

    NASA Astrophysics Data System (ADS)

    Yu, An; Geng, Tingting; Fu, Qiang; Chen, Chao; Cui, Yali

    2007-04-01

    Using GoldMag (Fe3O4/Au) nanoparticles as a carrier, a biotin-avidin amplified ELISA was developed to detect hepatitis B surface antigen (HBsAg). A specific antibody was labeled with biotin and then used to detect the antigen with an antibody coated on GoldMag nanoparticles by a sandwich ELISA assay. The results showed that 5 mol of biotin were surface bound per mole of antibody. The biotin-avidin amplified ELISA assay has a higher sensitivity than that of the direct ELISA assay. There is 5-fold difference between HBsAg positive and negative serum even at dilution of 1:10000, and the relative standard deviation of the parallel positive serum at dilution of 1:4000 is 5.98% (n=11).

  4. Evaluation of a sensitive reverse transcription PCR-enzymelinked immunosorbent assay for detection of hepatitis A virus in oysters (Saccostrea glomerata) on the east coast of the Gulf of Thailand.

    PubMed

    Intamaso, Uraiwan; Ketkhunthod, Sitthisak

    2014-05-01

    Hepatitis A virus (HAV) contamination in food can lead to major health problems. We developed a combination reverse transcription (RT) PCR method plus enzyme-linked immunosorbent assay (ELISA) to detect HAV in fresh oysters harvested along the east coast of the Gulf of Thailand. Viral nucleic acid was extracted via the glycine-arginine-polyethylene glycol method followed by RT-PCR amplification with specifically designed primers against HAV and an ELISA to detect the digoxigenin-labeled RT-PCR products. The ELISA in concert with the RT-PCR protocol further increased the detection sensitivity by 100-fold for the HAV genome and 10-fold in artificially contaminated oysters. The overall sensitivity of the RT-PCR in combination with the ELISA was 31.88 pg and 16 PFU/g, respectively. The ELISA increases the specificity of the RT-PCR assay for detecting naturally occurring HAV in oysters. This combined RT-PCR-ELISA approach is a practical and sensitive method for HAV detection and can be utilized in routine screening for HAV in shellfish.

  5. DEVELOPMENT OF DIOXIN TOXICITY EVALUATION METHOD IN HUMAN MILK BY ENZYME-LINKED IMMUNOSORBENT ASSAY-ASSAY VALIDATION FOR HUMAN MILK. (R825433)

    EPA Science Inventory

    In this study, the development of a toxicity evaluation method for dioxins in human milk by enzyme-linked immunosorbent assay (ELISA) was reported. A total of 17 human milk samples were tested by ELISA and by gas chromatography/mass spectrometry (GC/MS) to assess whether the E...

  6. A monoclonal antibody based elisa for quantitation of human leukaemia inhibitory factor.

    PubMed

    Taupin, J L; Gualde, N; Moreau, J F

    1997-02-01

    The authors report on the development of a new sandwich enzyme-linked immunoabsorbent assay (ELISA) for the quantitation of the human cytokine leukaemia inhibitory factor/human interleukin for DA cells (LIF/HILDA) with high accuracy and sensitivity (23 pg/ml), in less than 5 h and in various biological fluids. The antibodies used in this assay were raised against recombinant glycosylated LIF expressed in vivo following inoculation of recombinant vaccinia viruses, and screened with the biologically active cytokine in a flow cytometry assay using cells expressing a membrane-bound form of LIF. Furthermore, this home-made assay was compared with two commercially available ELISA kits. The results led to the conclusion that these three assays are far from being equivalent between each other, in terms of sensitivity towards non-glycosylated vs glycosylated LIF. Two major parameters must be incriminated: the glycosylation status of the LIF molecule used as the calibrator, and the binding characteristics of the monoclonal antibodies used to set up these assays toward LIF derived from Escherichia coli or from eukaryotic cells. This points out the importance of these parameters for the design of ELISAs meant for the quantitation of glycosylated cytokines in biological fluids.

  7. Validation of summer and winter ELISA measurements of serum 25-hydroxyvitamin D concentrations in Mongolia.

    PubMed

    Bromage, Sabri; Tselmen, Daria; Bradwin, Gary; Holick, Michael F; Ganmaa, Davaasaambuu

    2017-01-01

    Assay cost, quality, and availability pose challenges for vitamin D surveys in limited resource settings. This study aimed to validate an inexpensive vitamin D assay (ELISA) under real-world conditions in Mongolia, the northernmost developing country, to characterize the assay's usefulness and inform the design of epidemiologic studies in similar regions. We collected paired summer and winter serum samples from 120 men and women (aged 20-57 years) in urban and rural Mongolia, analyzed each sample for 25(OH)D concentration using both Immunodiagnostic Systems ELISA and DiaSorin LIAISON 25(OH)D TOTAL, and compared the assays using multiple statistics. LIAISON was itself validated by participation in the DEQAS program. Correlation and agreement between assays were higher in summer (Pearson's correlation=0.60, Spearman's rank correlation=0.67, Lin's concordance correlation=0.56) than winter (rP=0.37, rS=0.43, rC=0.33), although ELISA less accurately assigned subjects to sufficiency categories in summer (percent agreement=44%) than winter (58%), during the latter of which most subjects were deficient ([25(OH)D] categories used: >75 nmol/L (optimal), 50-75 nmol/L (adequate), 25-50 nmol/L (inadequate), <25 nmol/L (deficient)). Compared with LIAISON, ELISA tended to indicate higher vitamin D status in both seasons (mean paired difference: 7.0 nmol/L (95% CI: 3.5-10.5) in summer, 5.2 nmol/L (95% CI: 2.9-7.5) in winter). ELISA proved useful for measuring and ranking subjects' vitamin D status in Mongolia during summer, but levels were too low in winter to sensitively discriminate between subjects, and ELISA overestimated status in both seasons. These findings have implications for the timing and interpretation, respectively, of vitamin D surveys in highly deficient populations.

  8. Dynex: multiplex ELISA technology

    USDA-ARS?s Scientific Manuscript database

    Conventional enzyme linked immunosorbent assay (ELISA) is a gold standard for screening antibodies and testing for protein or antigen presence. A significant limitation of this assay resides in the fact that only one analyte can be assessed per microplate well. Here, we describe and investigate a ne...

  9. Cryopreservation induces macrophage colony stimulating factor from human periodontal ligament cells in vitro.

    PubMed

    Rhim, E-M; Ahn, S-J; Kim, J-Y; Chang, Y-R; Kim, K-H; Lee, H-W; Jung, S-H; Kim, E-C; Park, S-H

    2013-10-01

    Cryopreservation is used to protect vital periodontal ligaments during the transplantation of teeth. We investigated which gene products implicated in root resorption are upregulated in human periodontal ligament cells by cryopreservation, and whether cryopreservation affects the expression of macrophage-colony stimulating factor (M-CSF) in human periodontal ligament cells. We used customized microarrays to compare gene expression in human periodontal ligament cells cultured from teeth immediately after extraction and from cryopreserved teeth. Based on the result of these assays, we examined M-CSF expression in periodontal ligament cells from the immediately extracted tooth and cryopreserved teeth by real-time PCR, enzyme-linked immunosorbent assay (ELISA), Western blot analysis, and immunofluorescence. We also investigated whether human bone marrow cells differentiate into tartrate-resistant acid phosphatase (TRAP) positive osteoclasts when stimulated with RANKL (Receptor Activator for Nuclear Factor κ B Ligand) together with any secreted M-CSF present in the supernatants of the periodontal ligament cells cultured from the various groups of teeth. M-CSF was twofold higher in the periodontal ligament cells from the rapid freezing teeth than in those from the immediately extracted group (p < 0.05). Cryopreservation increased M-CSF expression in the periodontal ligament cells when analyzed by real time PCR, ELISA, Western blotting, and immunofluorescence (p < 0.05). TRAP positive osteoclasts were formed in response to RANKL and the secreted M-CSF present in the supernatants of all the experimental groups except negative control. These results demonstrate that cryopreservation promotes the production of M-CSF, which plays an important role in root resorption by periodontal ligament cells. Copyright © 2013 Elsevier Inc. All rights reserved.

  10. Enhanced Enzyme-Linked Immunosorbent Assay for Detection of Antibodies to Virus-Like Particles of Human Papillomavirus

    PubMed Central

    Studentsov, Yevgeniy Y.; Schiffman, Mark; Strickler, Howard D.; Ho, Gloria Y. F.; Pang, Yuk-Ying Susana; Schiller, John; Herrero, Rolando; Burk, Robert D.

    2002-01-01

    Measurement of antibodies to human papillomavirus (HPV) is complicated by many factors. Although enzyme-linked immunosorbent assays (ELISAs) that use virus-like particles (VLPs) have proved useful, the assays have, in general, had moderate sensitivities and low signal-to-noise ratios. To enhance the performance of the assay, a systematic investigation was undertaken to examine key variables used in ELISAs for the detection of antibodies to VLPs of HPV. Incorporation of two vinyl polymers, polyvinyl alcohol (molecular weight, 50,000) (PVA-50) and polyvinylpyrrolidone (molecular weight, 360,000) (PVP-360), was found to increase the sensitivity as well as the specificity of the assay for the detection of antibodies to VLPs of HPV. In particular, the addition of PVA-50 to the blocking solution reduced the amount of nonspecific binding of antibodies to VLPs and the microplate surface, whereas the addition of PVP-360 increased the sensitivity of antibody detection. The new ELISA demonstrated increased sensitivity and specificity for the detection of cervical HPV type 16 infection compared to those of a prototype assay with coded clinical serum samples from women with known cervicovaginal HPV infection status. It is anticipated that the enhanced ELISA conditions will have wide application to a large number of clinical diagnostic assays. PMID:11980956

  11. Enzyme-linked immunosorbent assay for detection of antibodies to Epstein-Barr virus antigens.

    PubMed

    Voevodin, A F; Pácsa, A S

    1983-01-01

    Enzyme-Linked Immunosorbent Assay (ELISA) was standardized for measurement of antibody activity of reference human and baboon (Papio hamadryas) sera to soluble Epstein-Barr virus (EBV) antigens. A comparison with the immunofluorescent (IF) method showed that ELISA detects antibody specifically and sensitivity. In ELISA, Herpesvirus Papio (HVP) nuclear antigen (HUPNA) positive baboon serum reacted with EBV nuclear antigen (EBNA), as a further indication of the antigenic similarity between HVP and EBV. Forty-two baboon sera were tested with EBV antigens in both ELISA and IF test. The results showed an agreement between the two methods and also that by the use of EBV antigens, ELISA measures anti-HVP activity of baboon sera. ELISA did not reveal significant difference in antibody activity of 23 baboons with lymphoma and that of 24 healthy baboons. Results provide further data that ELISA can be used effectively in the field of EBV serology.

  12. Quantitative enzyme-linked immunosorbent assay for determination of polychlorinated biphenyls in environmental soil and sediment samples.

    PubMed

    Johnson, J C; Van Emon, J M

    1996-01-01

    An enzyme-linked immunosorbent assay (ELISA) for the quantitative determination of Aroclors 1242, 1248, 1254, and 1260 in soil and sediments was developed and its performance compared with that of gas chromatography (GC). The detection limits for Aroclors 1242 and 1248 in soil are 10.5 and 9 ng/g, respectively. The assay linear dynamic range is 50-1333 ng/g. Cross-reactivity of the assay with 37 structurally related potential cocontaminants in environmental soil samples was examined; none of the chlorinated anisoles, benzenes, or phenols exhibited >3% cross-reactivity, with <0.1% cross-reactivity being the norm. Soil spike recoveries of 107% and 104% were obtained for Aroclors 1242 and 1248, respectively, for a spike level of 5 mg/kg, with corresponding relative standard deviations of 14% and 17%. One hundred forty-eight environmental soil, sediment, and paper pulp samples, obtained from two EPA listed Superfund sites, were analyzed by ELISA and standard GC methods. Samples were extracted for ELISA analysis by shaking with methanol. Additional extractions of the same samples were performed either with supercritical carbon dioxide or by Soxhlet extraction with methanol. ELISA results for both the supercritical fluid and the Soxhlet extracts were in close agreement with the GC results, while the ELISA results for the methanol shake extracts were not. The data for the environmental samples demonstrated the capability of the ELISA to provide accurate results and reinforced the dependence of any detection method, including ELISA, on appropriate extraction procedures.

  13. Comparison of Laboratory-Developed and Commercial Monoclonal Antibody-Based Sandwich Enzyme-Linked Immunosorbent Assays for Almond (Prunus dulcis) Detection and Quantification.

    PubMed

    Liu, Changqi; Chhabra, Guneet S; Zhao, Jing; Zaffran, Valerie D; Gupta, Sahil; Roux, Kenneth H; Gradziel, Thomas M; Sathe, Shridhar K

    2017-10-01

    A commercially available monoclonal antibody (mAb)-based direct sandwich enzyme-linked immunosorbent assay (ELISA) kit (BioFront Technologies, Tallahassee, Fla., U.S.A.) was compared with an in-house developed mAb 4C10-based ELISA for almond detection. The assays were comparable in sensitivity (limit of detection < 1 ppm full fat almond, limit of quantification < 5 ppm full fat almond), specificity (no cross-reactivity with 156 tested foods at a concentration of 100000 ppm whole sample), and reproducibility (intra- and interassay variability < 15% CV). The target antigens were stable and detectable in whole almond seeds subjected to autoclaving, blanching, frying, microwaving, and dry roasting. The almond recovery ranges for spiked food matrices were 84.3% to 124.6% for 4C10 ELISA and 81.2% to 127.4% for MonoTrace ELISA. The almond recovery ranges for commercial and laboratory prepared foods with declared/known almond amount were 30.9% to 161.2% for 4C10 ELISA and 38.1% to 207.6% for MonoTrace ELISA. Neither assay registered any false-positive or negative results among the tested commercial and laboratory prepared samples. Ability to detect and quantify trace amounts of almonds is important for improving safety of almond sensitive consumers. Two monoclonal antibody-based ELISAs were compared for almond detection. The information is useful to food industry, regulatory agencies, scientific community, and almond consumers. © 2017 Institute of Food Technologists®.

  14. Evaluation of a new serological technique for detecting rabies virus antibodies following vaccination.

    PubMed

    Ma, Xiaoyue; Niezgoda, Michael; Blanton, Jesse D; Recuenco, Sergio; Rupprecht, Charles E

    2012-08-03

    Two major techniques are currently used to estimate rabies virus antibody values: neutralization assays, such as the rapid fluorescent focus inhibition test (RFFIT), and enzyme-linked immunosorbent assays (ELISAs). The RFFIT is considered the gold standard assay and has been used to assess the titer of rabies virus neutralizing antibodies for more than three decades. In the late 1970s, ELISA began to be used to estimate the level of rabies virus antibody and has recently been used by some laboratories as an alternate screening test for animal sera. Although the ELISA appears simpler, safer and more efficient, the assay is less sensitive in detecting low values of rabies virus neutralizing antibodies than neutralization tests. This study was designed to evaluate a new ELISA-based method for detecting rabies virus binding antibody. This new technique uses electro-chemi-luminescence labels and carbon electrode plates to detect binding events. In this comparative study, the RFFIT and the new ELISA-based technique were used to evaluate the level of rabies virus antibodies in human and animal serum samples. By using a conservative approximation of 0.15 IU/ml as a cutoff point, the new ELISA-based technique demonstrated a sensitivity of 100% and a specificity of 95% for human samples and for experimental animal samples. The sensitivity and specificity for field animal samples was 96% and 95%, respectively. The preliminary results from this study appear promising and demonstrate a higher sensitivity than traditional ELISA methods. Published by Elsevier Ltd.

  15. Prevalence of antibodies to type A influenza virus in wild avian species using two serologic assays

    USGS Publications Warehouse

    Brown, Justin D.; Luttrell, M. Page; Berghaus, Roy D.; Kistler, Whitney; Keeler, Shamus P.; Howey, Andrea; Wilcox, Benjamin; Hall, Jeffrey S.; Niles, Larry; Dey, Amanda; Knutsen, Gregory; Fritz, Kristen; Stallknecht, David E.

    2010-01-01

    Serologic testing to detect antibodies to avian influenza (AI) virus has been an underused tool for the study of these viruses in wild bird populations, which traditionally has relied on virus isolation and reverse transcriptase-polymerase chain reaction (RT-PCR). In a preliminary study, a recently developed commercial blocking enzyme-linked immunosorbent assay (bELISA) had sensitivity and specificity estimates of 82% and 100%, respectively, for detection of antibodies to AI virus in multiple wild bird species after experimental infection. To further evaluate the efficacy of this commercial bELISA and the agar gel immunodiffusion (AGID) test for AI virus antibody detection in wild birds, we tested 2,249 serum samples collected from 62 wild bird species, representing 10 taxonomic orders. Overall, the bELISA detected 25.4% positive samples, whereas the AGID test detected 14.8%. At the species level, the bELISA detected as many or more positive serum samples than the AGID in all 62 avian species. The majority of positive samples, detected by both assays, were from species that use aquatic habitats, with the highest prevalence from species in the orders Anseriformes and Charadriiformes. Conversely, antibodies to AI virus were rarely detected in the terrestrial species. The serologic data yielded by both assays are consistent with the known epidemiology of AI virus in wild birds and published reports of host range based on virus isolation and RT-PCR. The results of this research are also consistent with the aforementioned study, which evaluated the performance of the bELISA and AGID test on experimental samples. Collectively, the data from these two studies indicate that the bELISA is a more sensitive serologic assay than the AGID test for detecting prior exposure to AI virus in wild birds. Based on these results, the bELISA is a reliable species-independent assay with potentially valuable applications for wild bird AI surveillance.

  16. Comparison of commercial enzyme-linked immunosorbent assay kits with agar gel precipitation and hemagglutination-inhibition tests for detecting antibodies to avian influenza viruses.

    PubMed

    Shiraishi, Rikiya; Nishiguchi, Akiko; Tsukamoto, Kenji; Muramatsu, Masatake

    2012-09-01

    We evaluated the utility of 5 commercial enzyme-linked immunosorbent assay (ELISA) kits for detecting antibodies to avian influenza viruses. The sensitivities and specificities of the ELISA kits were compared with those of the agar gel precipitation (AGP) and hemagglutination-inhibition (HI) tests. The results suggest that some ELISA kits might not be suitable for monitoring during the early stages of avian influenza virus infections. Therefore, ELISA kits should only be used in conjunction with a profound knowledge about monitoring of avian influenza.

  17. 9 CFR 146.13 - Testing.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ...) Enzyme-linked immunosorbent assay (ELISA). ELISA must be conducted using test kits approved by the... conducted on all ELISA-positive samples. (B) The AGID test must be conducted using reagents approved by the...

  18. 9 CFR 146.13 - Testing.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ...) Enzyme-linked immunosorbent assay (ELISA). ELISA must be conducted using test kits approved by the... conducted on all ELISA-positive samples. (B) The AGID test must be conducted using reagents approved by the...

  19. 9 CFR 146.13 - Testing.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ...) Enzyme-linked immunosorbent assay (ELISA). ELISA must be conducted using test kits approved by the... conducted on all ELISA-positive samples. (B) The AGID test must be conducted using reagents approved by the...

  20. 9 CFR 146.13 - Testing.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ...) Enzyme-linked immunosorbent assay (ELISA). ELISA must be conducted using test kits approved by the... conducted on all ELISA-positive samples. (B) The AGID test must be conducted using reagents approved by the...

  1. 9 CFR 146.13 - Testing.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ...) Enzyme-linked immunosorbent assay (ELISA). ELISA must be conducted using test kits approved by the... conducted on all ELISA-positive samples. (B) The AGID test must be conducted using reagents approved by the...

  2. Critical evaluation of a specific ELISA and two enzymatic assays of pancreatic lipases in human sera.

    PubMed

    Grandval, Philippe; De Caro, Alain; De Caro, Josiane; Sias, Barbara; Carrière, Frédéric; Verger, Robert; Laugier, René

    2004-01-01

    Human pancreatic lipases (HPL) include the classical HPL, and two related proteins known as pancreatic lipase-related proteins 1 and 2 (HPLRP1 and 2). The aim of this study was to develop an ELISA for specifically quantifying the classical-HPL level in sera of patients with and without pancreatic disorders. The specific activity of various human (including classical-HPL) and microbial lipases was measured using Lipa Vitros and potentiometric (pH-stat) assays. A double sandwich ELISA was also set up, using an anti-classical-HPL polyclonal antibody and a biotinylated monoclonal antibody (mAb 146-40) specific to the classical-HPL. Sera (n = 53) were collected from patients with and without pancreatic disorders. The lipase concentration was deduced from the measured lipolytic activity and compared with the corresponding classical-HPL concentration, measured with the ELISA. Both the purified HPLRP2 and 3 lipases of microbial origin were found to have a significant and unexpected lipolytic activity under the standard Lipa Vitros assay, whereas the ELISA test developed in the present study was found to be specific for the classical-HPL, due to the absence of cross-reactivity between mAb 146-40, HPLRP1 and HPLRP2. The efficiency of the ELISA was assessed in terms of its reproducibility and accuracy. The lower detection limit of classical-HPL was found to be 0.03 microg/l. A good correlation was found to exist between the lipase concentrations obtained in the ELISA, pH-stat and Lipa Vitros tests, in both the control and pathological groups. This is the first time a specific method of measuring classical-HPL in human serum has been proposed. Using this ELISA, we established with the 53 sera selected in the present study, that the Lipa Vitros assay as well as the pH-stat assay were mostly detecting classical pancreatic lipase. However, it is possible that other lipases such as HPLRP2 or lipases of microbial origin, present in some pathological sera, may well interfere with the Lipa Vitros assay. Copyright 2004 S. Karger AG, Basel and IAP.

  3. Development of an enzyme-linked immunosorbent assay for detection of chicken osteocalcin and its use in evaluation of perch effects on bone remodeling in caged White Leghorns.

    PubMed

    Jiang, S; Cheng, H W; Hester, P Y; Hou, J-F

    2013-08-01

    Osteocalcin (OC) is a sensitive biochemical marker for evaluating bone turnover in mammals. The role of avian OC is less clear because of the need for a chicken assay. Our objectives were to develop an assay using indirect competitive ELISA for detecting chicken serum OC and use the assay to examine the effects of perches on bone remodeling in caged hens. Anti-chicken OC polyclonal antibody was produced by immunization of rabbits with a recombinant OC from Escherichia coli. Chicken OC extracted from bone was used as a coated protein, and purified chicken OC was used for calibration. The limit of detection of the developed OC ELISA was 0.13 ng/mL. The intra- and interassay CV were <7 and <12%, respectively. The sensitivity of the developed OC ELISA was compared with a commercial Rat-Mid OC ELISA in laying hens housed in conventional cages with or without perches. Serum samples were collected from 71-wk-old White Leghorn hens subjected to 4 treatments. Treatment 1 was control chickens that never had access to perches during their life cycle. Treatment 2 chickens had perches during the pullet phase (0 to 16.9 wk of age), whereas treatment 3 chickens had perches only during the egg-laying phase of the life cycle (17 to 71 wk of age). Treatment 4 chickens always had access to perches (0 to 71 wk of age). Correlation between the 2 assays was 0.62 (P < 0.0001). Levels of serum OC using the developed chicken ELISA were higher than that detected using the Rat-Mid ELISA (P < 0.0001). Results from the chicken ELISA assay showed that hens with perch access had higher concentrations of serum OC than hens without perches during egg laying (P = 0.04). Pullet access to perches did not affect serum OC levels in 71-wk-old hens (P = 0.15). In conclusion, a chicken OC ELISA has been validated that is sensitive and accurate with adequate discriminatory power for measuring bone remodeling in chickens.

  4. Optimal Cutoff and Accuracy of an IgM Enzyme-Linked Immunosorbent Assay for Diagnosis of Acute Scrub Typhus in Northern Thailand: an Alternative Reference Method to the IgM Immunofluorescence Assay

    PubMed Central

    Blacksell, Stuart D.; Tanganuchitcharnchai, Ampai; Jintaworn, Suthatip; Kantipong, Pacharee; Richards, Allen L.; Day, Nicholas P. J.

    2016-01-01

    The enzyme-linked immunosorbent assay (ELISA) has been proposed as an alternative serologic diagnostic test to the indirect immunofluorescence assay (IFA) for scrub typhus. Here, we systematically determine the optimal sample dilution and cutoff optical density (OD) and estimate the accuracy of IgM ELISA using Bayesian latent class models (LCMs). Data from 135 patients with undifferentiated fever were reevaluated using Bayesian LCMs. Every patient was evaluated for the presence of an eschar and tested with a blood culture for Orientia tsutsugamushi, three different PCR assays, and an IgM IFA. The IgM ELISA was performed for every sample at sample dilutions from 1:100 to 1:102,400 using crude whole-cell antigens of the Karp, Kato, and Gilliam strains of O. tsutsugamushi developed by the Naval Medical Research Center. We used Bayesian LCMs to generate unbiased receiver operating characteristic curves and found that the sample dilution of 1:400 was optimal for the IgM ELISA. With the optimal cutoff OD of 1.474 at a sample dilution of 1:400, the IgM ELISA had a sensitivity of 85.7% (95% credible interval [CrI], 77.4% to 86.7%) and a specificity of 98.1% (95% CrI, 97.2% to 100%) using paired samples. For the ELISA, the OD could be determined objectively and quickly, in contrast to the reading of IFA slides, which was both subjective and labor-intensive. The IgM ELISA for scrub typhus has high diagnostic accuracy and is less subjective than the IgM IFA. We suggest that the IgM ELISA may be used as an alternative reference test to the IgM IFA for the serological diagnosis of scrub typhus. PMID:27008880

  5. Hybridization chain reaction amplification for highly sensitive fluorescence detection of DNA with dextran coated microarrays.

    PubMed

    Chao, Jie; Li, Zhenhua; Li, Jing; Peng, Hongzhen; Su, Shao; Li, Qian; Zhu, Changfeng; Zuo, Xiaolei; Song, Shiping; Wang, Lianhui; Wang, Lihua

    2016-07-15

    Microarrays of biomolecules hold great promise in the fields of genomics, proteomics, and clinical assays on account of their remarkably parallel and high-throughput assay capability. However, the fluorescence detection used in most conventional DNA microarrays is still limited by sensitivity. In this study, we have demonstrated a novel universal and highly sensitive platform for fluorescent detection of sequence specific DNA at the femtomolar level by combining dextran-coated microarrays with hybridization chain reaction (HCR) signal amplification. Three-dimensional dextran matrix was covalently coated on glass surface as the scaffold to immobilize DNA recognition probes to increase the surface binding capacity and accessibility. DNA nanowire tentacles were formed on the matrix surface for efficient signal amplification by capturing multiple fluorescent molecules in a highly ordered way. By quantifying microscopic fluorescent signals, the synergetic effects of dextran and HCR greatly improved sensitivity of DNA microarrays, with a detection limit of 10fM (1×10(5) molecules). This detection assay could recognize one-base mismatch with fluorescence signals dropped down to ~20%. This cost-effective microarray platform also worked well with samples in serum and thus shows great potential for clinical diagnosis. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Diagnosis of murine mycoplasmal infections by enzyme-linked immunosorbent assay (ELISA).

    PubMed

    Davis, J; Cassell, G H; Gambill, G; Cox, N; Watson, H; Davidson, M

    1987-06-01

    ELISA is the currently accepted method for screening rodent colonies for Mycoplasma pulmonis infection. While this assay has greatly improved mycoplasmal detection, it suffers from major defects. Cross-reactions with M. arthritidis are the major technical problem, and prevent definitive diagnosis. Current methods for obtaining a definitive diagnosis are accurate in about 80% of cases, and include ELISA testing for both organisms, immunoblot analysis, and blocking of the murine reaction with heterologous serum. Another technical difficulty is the inherent variability in the assay, which can be overcome by rigid quality control measures and careful attention to detail. The difficulties that arise from the natural history of mycoplasmal infection in barrier-maintained colonies, i.e., low incidence of infected animals and delayed antibody response in animals infected with low numbers of organisms, seriously limit the usefulness of the ELISA. While the assay can be extremely useful in screening breeding colonies and in eliminating mycoplasmas from such colonies, it cannot easily be used to screen potential sources of weanling animals for experimental use.

  7. Development of a Sensitive Luciferase-Based Sandwich ELISA System for the Detection of Human Extracellular Matrix 1 Protein.

    PubMed

    Li, Ya; Li, Yanqing; Zhao, Junli; Zheng, Xiaojing; Mao, Qinwen; Xia, Haibin

    2016-12-01

    Enzyme-linked immunosorbent assay (ELISA) has been one of the main methods for detecting an antigen in an aqueous sample for more than four decades. Nowadays, one of the biggest concerns for ELISA is still how to improve the sensitivity of the assay, and the luciferase-luciferin reaction system has been noticed as a new detection method with high sensitivity. In this study, a luciferin-luciferase reaction system was used as the detection method for a sandwich ELISA system. It was shown that this new system led to an increase in the detection sensitivity of at least two times when compared with the traditional horseradish peroxidase (HRP) detection method. Lastly, the serum levels of the human extracellular matrix 1 protein of breast cancer patients were determined by the new system, which were overall similar to the HRP chemiluminescent system. Furthermore, this new luciferase reporter can be implemented into other ELISA systems for the purpose of increasing the assay sensitivity.

  8. An ELISA DYRK1A non-radioactive kinase assay suitable for the characterization of inhibitors

    PubMed Central

    Liu, Yong; Adayev, Tatyana; Hwang, Yu-Wen

    2017-01-01

    The DYRK1A (dual specificity tyrosine phosphorylation-regulated kinase 1A) gene encodes a proline-directed Ser/Thr kinase. Elevated expression and/or altered distribution of the kinase have been implicated in the neurological impairments associated with Down syndrome (DS) and Alzheimer’s disease (AD). Consequently, DYRK1A inhibition has been of significant interest as a potential strategy for therapeutic intervention of DS and AD. Many classes of novel inhibitors have been described in the past decade. Although non-radioactive methods for analyzing DYRK1A inhibition have been developed, methods employing radioactive tracers are still commonly used for quantitative characterization of DYRK1A inhibitors. Here, we present a non-radioactive ELISA assay based on the detection of DYRK1A-phosphorylated dynamin 1a fragment using a phosphorylation site-specific antibody. The assay was verified by the use of two well-characterized DYRK1A inhibitors, epigallocatechin gallate (EGCG) and harmine. The IC 50s for EGCG and harmine determined by the ELISA method were found to be comparable to those previously measured by radioactive tracing methods.  Furthermore, we determined the mode of inhibition for EGCG and harmine by a modification of the ELISA assay. This assay confirms the mode of inhibition of EGCG (non-ATP-competitive) and harmine (ATP-competitive), as previously determined. We conclude that the ELISA platform demonstrated here is a viable alternative to the traditional radioactive tracer assays for analyzing DYRK1A inhibitors. PMID:28163906

  9. A lactate dehydrogenase ELISA-based assay for the in vitro determination of Plasmodium berghei sensitivity to anti-malarial drugs.

    PubMed

    Orjuela-Sánchez, Pamela; Duggan, Erika; Nolan, John; Frangos, John A; Carvalho, Leonardo Jm

    2012-11-05

    Plasmodium berghei rodent malaria is a well-known model for the investigation of anti-malarial drug efficacy in vivo. However, the availability of drug in vitro assays in P. berghei is reduced when compared with the spectrum of techniques existing for Plasmodium falciparum. New alternatives to the current manual or automated methods described for P. berghei are attractive. The present study reports a new ELISA drug in vitro assay for P. berghei using two monoclonal antibodies against the parasite lactate dehydrogenase (pLDH). This procedure includes a short-in vitro culture, the purification of schizonts and the further generation of synchronized mice infections. Early stages of the parasite are then incubated against different concentrations of anti-malarial drugs using micro-plates. The novelty of this procedure in P. berghei relies on the quantification of the drug activity derived from the amount of pLDH estimated by an ELISA assay using two monoclonal antibodies: 14C1 and 19G7. The IC₅₀s obtained through the ELISA assay were compared with those from the micro-test. The initial parameters of the synchronized samples used in the in vitro assays were a parasitaemia of 0.5% and haematocrit of 1%, with an incubation period of 22 hours at 36.5°C. pLDH detection using a 14C1 coating at 10 μg/ml and 19G7 at 2.5 × 10⁻³ μg/ml provided good readouts of optical densities with low background in negative controls and specific detection levels for all parasite stages. IC₅₀s values derived from the ELISA assay for artesunate, chloroquine, amodiaquine and quinine were: 15, 7, 2, and 144 nM, respectively. When artesunate and chloroquine IC₅₀s were evaluated using the micro-test similar values were obtained. This ELISA-based in vitro drug assay is easy to implement, fast, and avoids the use radioisotopes or expensive equipment. The utility of this simple assay for screening anti-malarial drug activity against P. berghei in vitro is demonstrated.

  10. Determination of antibody response to influenza virus surface glycoproteins by kinetic enzyme-linked immunosorbent assay.

    PubMed Central

    Snyder, M H; Banks, S; Murphy, B R

    1988-01-01

    We modified an existing enzyme-linked immunosorbent assay (ELISA) to be able to use new spectrophotometers which can measure the rate of color development in microtiter wells. This new kinetic-based ELISA (KELISA) required only a single dilution of specimen rather than the multiple dilutions required with endpoint ELISA. In addition, 10- to 100-fold-less specimen was required to perform the KELISA than the ELISA. The level of serum or nasal wash antibody against surface glycoproteins of influenza A or influenza B viruses determined by KELISA was reproducible and correlated highly with the results of endpoint ELISA or hemagglutination inhibition tests. The difference between the KELISA rates, which indicated than an antibody response to infection had occurred, was defined and was analogous to a 2.2-fold rise in titer for serum and a 3.4-fold rise in titer for nasal wash determined by endpoint ELISA. The KELISA was similar to endpoint ELISAs in its ability to detect rises in antibody level in paired serum or nasal wash specimens obtained from volunteers who received live attenuated influenza A reassortant virus vaccines. By eliminating the need for multiple dilutions, the use of KELISA offers the advantage of increasing the number of assays that can be performed by the same personnel compared with endpoint ELISA, while it maintains sensitivity and specificity. PMID:3182992

  11. Development and Application of an Indirect Enzyme-Linked Immunosorbent Assay Using Recombinant Mag1 for Serodiagnosis of Toxoplasma gondii In Dogs.

    PubMed

    Zhuo, Xunhui; Sun, Hongchao; Zhang, Zhi; Luo, Jiaqing; Shan, Ying; Du, Aifang

    2017-06-01

    Serologic tests are widely accepted and applied as means to detect anti- Toxoplasma gondii immunoglobulin G antibodies. In this study, recombinant matrix antigen (rMAG1) was induced by isopropyl-β-d-thiogalactoside and purified by nickel-nitrilotriacetic acid purification system. We then developed and optimized an indirect enzyme-linked immunosorbent assay (ELISA) through checkerboard assays using serial dilutions of antigens and sera to assess the potential use of rMAG1 in serologic detection of T. gondii infection in dogs. Serum samples from 93 domestic dogs were analyzed by western blot and rMAG1-ELISA. The results were compared with those obtained from an ELISA with the soluble Toxoplasma lysate antigens (TLA). We found that although yielding an excellent agreement (96.7%) with western blot data (κ = 0.9659), rMAG1-ELISA produced higher sensitivity (93.9% vs. 87.8%) and specificity (98.3% vs. 96.7%) than TLA-ELISA. In addition, receiver operating characteristic analysis also revealed that rMAG1-ELISA is in more agreement with western blot (area under the curve [AUC] = 0.985) relative to TLA-ELISA (AUC = 0.955). These results indicated that the rMAG1-ELISA established in this study provides a promising and reliable tool for serologic detection of T. gondii infection in dogs.

  12. Development and Application of a Saccharomyces cerevisiae-Expressed Nucleocapsid Protein-Based Enzyme-Linked Immunosorbent Assay for Detection of Antibodies against Infectious Bronchitis Virus

    PubMed Central

    Gibertoni, Aliandra M.; Montassier, Maria de Fátima S.; Sena, Janete A. D.; Givisiez, Patrícia E. N.; Furuyama, Cibele R. A. G.; Montassier, Hélio J.

    2005-01-01

    A Saccharomyces cerevisiae-expressed nucleocapsid (N) polypeptide of the M41 strain of infectious bronchitis virus (IBV) was used as antigen in a recombinant yeast-expressed N protein-based enzyme-linked immunosorbent assay (Y-N-ELISA). The Y-N-ELISA was rapid, sensitive, and specific for detecting chicken serum antibodies to IBV, and it compared favorably with a commercial ELISA. PMID:15815038

  13. Comparison of 2 Luminex-based Multiplexed Protein Assays for Quantifying Microglia Activation and Inflammatory Proteins

    DTIC Science & Technology

    2016-04-01

    streptavidin-phycoerythrin (PE) similar to sandwich enzyme-linked immunosorbent assays ( ELISAs ). The 3 fluorescent markers (2 beads plus PE) allow for...within the kit, this worked out to a set of expensive, problematic, and subjective ELISA . The space on the black-96 well plate was split between cell...ARL US Army Research Laboratory BBB blood–brain barrier CSF cerebral spinal fluid DOD US Department of Defense ELISA enzyme-linked immunosorbent

  14. Development and evaluation of an avian influenza (AI) neuraminidase subtype 1 (N1) based serological ELISA for poultry using the differentiation of infected and vaccinated animals (DIVA)approach

    USDA-ARS?s Scientific Manuscript database

    An indirect enzyme-linked immunosorbent assay (ELISA) was developed using baculovirus expressed N1 protein from the A/CK/Indonesia/PA/2003 (H5N1) virus. The specificity of the assay was tested with a panel of chicken anti-sera raised against N1 to N9 virus subtypes. The N1-ELISA was specific for t...

  15. A Sandwich ELISA for Adducts of Polycyclic Aromatic Hydrocarbons with Human Serum Albumin1

    PubMed Central

    Chung, Ming Kei; Riby, Jacques; Li, He; Iavarone, Anthony T.; Williams, Evan R.; Zheng, Yuxin; Rappaport, Stephen M.

    2010-01-01

    Adducts of benzo[α]pyrene-diolepoxide (BPDE)2 with blood nucleophiles have been used as biomarkers of exposure to polycyclic aromatic hydrocarbons (PAHs). The most popular such assay is a competitive ELISA which employs monoclonal antibody 8E11 to detect benzo[α]pyrene tetrols following hydrolysis of BPDE adducts from lymphocyte DNA or human serum albumin (HSA). Here we use 8E11 as the capture antibody in a sandwich ELISA to detect BPDE-HSA adducts directly in 1 mg samples of HSA or 20 μL of serum/plasma. The assay employs an anti-HSA antibody for detection, which is amplified by an avidin/biotinylated horseradish peroxidase complex. The sandwich ELISA has advantages of specificity and simplicity and is about 10 times more sensitive than the competitive ELISA. To validate the assay, HSA samples were assayed from three populations with known high (coke-oven workers), medium (steel-factory control workers), and low (volunteer subjects) PAH exposures (n = 30). The respective geometric mean levels of BPDE-HSA adducts, i.e., 67.8, 14.7 and 1.93 ng/mg HSA (1,010, 220 and 28.9 fmol BPDE equivalents/mg HSA), were significantly different (p < 0.05). The sandwich ELISA will be useful for screening PAH exposures in large epidemiologic studies and can be extended to other adducts for which capture antibodies are available. PMID:20083082

  16. A new ELISA for determination of potency in snake antivenoms.

    PubMed

    Rial, A; Morais, V; Rossi, S; Massaldi, H

    2006-09-15

    A competitive ELISA for potency determination of bothropic equine antivenom was developed and compared to the conventional in vivo ED(50) assay, with the aim of partially substituting the in vivo assay in the monitoring of antivenom immunoglobulin levels. On this purpose, blood samples were taken at different times during and after the immunization protocol of the lot of horses used for production of snake antivenom at the Instituto de Higiene, Uruguay. Both the competitive ELISA and the ED(50) assay were performed on those samples. In addition, a group of five commercial pepsin-digested antivenoms were tested by both methods. A significant (P<0.001) correlation (Pearson's r=0.957) was found between the ELISA titres and the corresponding ED(50) values, indicating that the in vitro test can estimate the neutralizing antibody capacity of the sera as well as the in vivo assay. By means of this new ELISA, it was found that the immunized animals maintained good venom antibody titres, in the order of 20-50% of the maximum achieved, even 10 month after the end of the immunization schedule. The main advantage of our ELISA design is its ability to correctly estimate the neutralization capacity of crude hyperimmune plasma and antivenom sera independently of their antibody composition in terms of whole IgG or F(ab')(2) fragment.

  17. Production of a monoclonal antibody against serum immunoglobulin M of South American camelids and assessment of its suitability in two immunoassays.

    PubMed

    Friedrich, Adrián; Ledesma, Martín; Landone, Ignacio; Ferrari, Alejandro; Leoni, Juliana

    2014-09-01

    A monoclonal antibody (mAb) was produced against immunoglobulin M (IgM) of South American camelids. A single radial immunodiffusion (SRID) assay and a competitive enzyme-linked immunosorbent assay (ELISA) were developed to measure IgM in serum samples. Isotype and specificity of the mAb were assessed. The performance of the SRID assay was preliminarily evaluated in terms of working range, plate stability over a 4-week period, and initial intra- and interassay variation. The concentration of IgM was determined in 55 samples by SRID assay and ELISA, and results were not significantly different by t-test (0.64 ± 0.19 mg/ml for the SRID assay, and 0.58 ± 0.24 mg/ml for ELISA; P = 0.1489). The mAb was shown to be stable over the 4-week evaluation period, and the SRID assay was reproducible when tested in triplicate for intra-assay variability and in quadruplicate for interassay variability, with a percentage coefficient of variation of less than or equal to 5%. Also, the SRID assay proved to be sensitive enough to measure IgM levels in undiluted serum samples, and had a good correlation with ELISA. The current study is intended to submit a preliminary report of a mAb against IgM of South American camelids, and suggest the future potential of the mAb developed for diagnostic application, including use in the SRID assay. © 2014 The Author(s).

  18. ELISA assays and alcohol: increasing carbon chain length can interfere with detection of cytokines

    PubMed Central

    von Maltzan, Kristine; Pruett, Stephen B.

    2010-01-01

    Enzyme-linked immunosorbent assays (ELISA) are frequently used in studies on cytokine production in response to treatment of cell cultures or laboratory animals. When an ELISA assay is performed on cell culture supernatants, samples often contain the treatment agents. The purpose of the present study was to determine if some of the agents evaluated might inhibit cytokine detection by interfering with the ELISA, leaving the question of whether cytokine production was inhibited unanswered. Mouse and human cytokine ELISA kits from BD Biosciences were used according to the manufacturer’s instructions. Cytokine proteins were subjected to one to five carbon alcohols at 86.8 mM (methanol, ethanol, 1-propanol, 2-propanol, n-butanol, and n-pentanol). After treating cell cultures with alcohols of different carbon chain lengths, we found that some of the alcohols interfered with measurement of some cytokines by ELISA, thus making their effects on cytokine production by cells in culture unclear. Increasing carbon chain length of straight chain alcohols positively correlated with their ability to inhibit detection of TNF-α and IL-10, but not with the detection of IL-6, IL-8, and IL-12. To avoid misinterpretation of treatment effects, ELISA assays should be tested with the reference protein and the treatment agent first, before testing biological samples. These results along with other recent results we obtained using circular dichroism indicate that alcohols with 2 or more carbons can directly alter protein conformation enough to disrupt binding in an ELISA (shown in the present study) or to inhibit ligand induced conformational changes (results not shown). Such direct effects have not been given enough consideration as a mechanism of ethanol action in the immune system. PMID:20843633

  19. Comparison of four diagnostic tests for the identification of serum antibodies in small ruminants infected with Mycoplasma agalactiae.

    PubMed

    Kittelberger, R; O'Keefe, J S; Meynell, R; Sewell, M; Rosati, S; Lambert, M; Dufour, P; Pépin, M

    2006-02-01

    To determine the diagnostic capability of a newly developed Western blot (WB) assay for the detection of serum antibodies against Mycoplasma agalactiae compared with conventional serological tests, and to identify the best test for routine diagnostic use. The serological test methods used were: two commercial indirect enzyme-linked immunosorbent assays (ELISA), viz ELISA-1, using a bacterial antigen preparation, and ELISA-2, using a recombinant protein (lipoprotein p48) antigen; the complement fixation test (CFT); and a newly developed WB assay, the latter both using a bacterial antigen preparation. Thirty sera from goats infected with M. agalactiae and 97 sera from non-infected sheep were tested using all four methods. Staining patterns in the WB were quite variable. An immuno-dominant band of 41 kDa was detected in 63% of sera from infected animals. The same band also appeared, although mostly very weakly, in 10% of sera from non-infected animals. When suspicious or very weak reactors were omitted, the diagnostic sensitivity (DSE) and diagnostic specificity (DSP), respectively, for the four assays were: WB=56.7%, 97.9%; ELISA-1=76.7%, 99.0%; ELISA-2=56.7%, 100%; and CFT=40.0%, 94.8%. ELISA-1 performed best in this comparison. While the WB can be used, it did not have a technical advantage over the ELISA. The CFT should be discouraged as the primary screening method for contagious agalactia and should be replaced by ELISA-1. Results from this study confirm that serological test methods for contagious agalactia are useful for the detection of infected flocks but will not detect every individual infected animal.

  20. DNA Microarray Detection of 18 Important Human Blood Protozoan Species

    PubMed Central

    Chen, Jun-Hu; Feng, Xin-Yu; Chen, Shao-Hong; Cai, Yu-Chun; Lu, Yan; Zhou, Xiao-Nong; Chen, Jia-Xu; Hu, Wei

    2016-01-01

    Background Accurate detection of blood protozoa from clinical samples is important for diagnosis, treatment and control of related diseases. In this preliminary study, a novel DNA microarray system was assessed for the detection of Plasmodium, Leishmania, Trypanosoma, Toxoplasma gondii and Babesia in humans, animals, and vectors, in comparison with microscopy and PCR data. Developing a rapid, simple, and convenient detection method for protozoan detection is an urgent need. Methodology/Principal Findings The microarray assay simultaneously identified 18 species of common blood protozoa based on the differences in respective target genes. A total of 20 specific primer pairs and 107 microarray probes were selected according to conserved regions which were designed to identify 18 species in 5 blood protozoan genera. The positive detection rate of the microarray assay was 91.78% (402/438). Sensitivity and specificity for blood protozoan detection ranged from 82.4% (95%CI: 65.9% ~ 98.8%) to 100.0% and 95.1% (95%CI: 93.2% ~ 97.0%) to 100.0%, respectively. Positive predictive value (PPV) and negative predictive value (NPV) ranged from 20.0% (95%CI: 2.5% ~ 37.5%) to 100.0% and 96.8% (95%CI: 95.0% ~ 98.6%) to 100.0%, respectively. Youden index varied from 0.82 to 0.98. The detection limit of the DNA microarrays ranged from 200 to 500 copies/reaction, similar to PCR findings. The concordance rate between microarray data and DNA sequencing results was 100%. Conclusions/Significance Overall, the newly developed microarray platform provides a convenient, highly accurate, and reliable clinical assay for the determination of blood protozoan species. PMID:27911895

  1. A Multiplex Microsphere-Based Immunoassay Increases the Sensitivity of SIV-Specific Antibody Detection in Serum Samples and Mucosal Specimens Collected from Rhesus Macaques Infected with SIVmac239.

    PubMed

    Powell, Rebecca L R; Ouellette, Ian; Lindsay, Ross W; Parks, Christopher L; King, C Richter; McDermott, Adrian B; Morrow, Gavin

    2013-06-01

    Results from recent HIV-1 vaccine studies have indicated that high serum antibody (Ab) titers may not be necessary for Ab-mediated protection, and that Abs localized to mucosal sites might be critical for preventing infection. Enzyme-linked immunosorbent assay (ELISA) has been used for decades as the gold standard for Ab measurement, though recently, highly sensitive microsphere-based assays have become available, with potential utility for improved detection of Abs. In this study, we assessed the Bio-Plex(®) Suspension Array System for the detection of simian immunodeficiency virus (SIV)-specific Abs in rhesus macaques (RMs) chronically infected with SIV, whose serum or mucosal SIV-specific Ab titers were negative by ELISA. We developed a SIVmac239-specific 4-plex bead array for the simultaneous detection of Abs binding to Env, Gag, Pol, and Nef. The 4-plex assay was used to quantify SIV-specific serum IgG and rectal swab IgA titers from control (SIV-naive) and SIVmac239-infected RMs. The Bio-Plex assay specifically detected anti-SIV Abs in specimens from SIV-infected animals for all four analytes when compared to SIV-naive control samples (p≤0.04). Furthermore, in 70% of Env and 79% of Gag ELISA-negative serum samples, specific Ab was detected using the Bio-Plex assay. Similarly, 71% of Env and 48% of Gag ELISA-negative rectal swab samples were identified as positive using the Bio-Plex assay. Importantly, assay specificity (i.e., probability of true positives) was comparable to ELISA (94%-100%). The results reported here indicate that microsphere-based methods provide a substantial improvement over ELISA for the detection of Ab responses, aid in detecting specific Abs when analyzing samples containing low levels of Abs, such as during the early stages of a vaccine trial, and may be valuable in attempts to link protective efficacy of vaccines with induced Ab responses.

  2. Sandwich-dot enzyme-linked immunosorbent assay for the detection of canine distemper virus

    PubMed Central

    Li, Zhi; Zhang, Yanlong; Wang, Huiguo; Jin, Jinhua; Li, Wenzhe

    2013-01-01

    A sandwich-dot enzyme-linked immunosorbent assay (dot ELISA) was developed for the detection of canine distemper virus (CDV). In 56 dogs suspected to have CD the rates of detection of CDV antigen in samples of blood lymphocytes and palpebral conjunctiva by dot ELISA and ELISA were, respectively, 91% (49/54) and 81% (44/54) for the lymphocyte samples and 88% (28/32) and 75% (24/32) for the conjunctival samples. The CDV detection limits were 10 ng/50 μL for dot ELISA and 40 ng/50 μL for ELISA. The reliability of dot ELISA relative to electron microscopy was 96% with 22 samples: all 21 samples in which CDV particles were observed by electron microscopy yielded positive results with dot ELISA; the single sample in which particles were not observed yielded false-positive results with dot ELISA. The results indicate that the dot ELISA developed can serve as a reliable rapid diagnostic test in suspected cases of CD and also be useful for epidemiologic surveillance of the disease. PMID:24124274

  3. Seroprevalence of Toxoplasma gondii in southern districts of Tamil Nadu using IgG-ELISA.

    PubMed

    Sucilathangam, G; Palaniappan, N; Sreekumar, C; Anna, T

    2012-10-01

    The present study was conducted to assess the seroprevalence of Toxoplasma gondii in and around Tirunelveli by in-house IgG assay using ELISA. Serum samples from 175 immunodeficient and 175 immunocompetent patients were collected at Tirunelveli district, Tamil Nadu from May 2006 to October 2007. They were subjected into in-house IgG assay using enzyme-linked immune sorbent assay (ELISA) in which tachyzoite soluble antigen derived from solubilised whole organisms was used. Out of 350 patients tested by IgG ELISA, 46 patients (13.14%) had antibodies for toxoplasmosis with mean OD value of 0.2 ± 0.073 and the OD value ranged from 0.144 to 0.444. Among the immunocompetent group of 175 patients, 19 patients (10.86%) had antibodies to toxoplasmosis whereas, in immunodeficient group of 175 patients, 27 patients (15.43%) had antibodies for toxoplasmosis. There was no statistical difference (P > 0.05) between the immunocompetent and immunodeficient group. The sensitivity and specificity of IgG ELISA in detecting toxoplasmosis was 90 and 100%, respectively. The overall seroprevalence of toxoplasmosis in and around Tirunelveli district of Tamil Nadu was 13.14% based on IgG ELISA. The study has proved ELISA to be a sensitive and specific procedure for the serodiagnosis of toxoplasmosis.

  4. Plasma osteopontin levels in patients with head and neck cancer and cervix cancer are critically dependent on the choice of ELISA system.

    PubMed

    Vordermark, Dirk; Said, Harun M; Katzer, Astrid; Kuhnt, Thomas; Hänsgen, Gabriele; Dunst, Jürgen; Flentje, Michael; Bache, Matthias

    2006-08-15

    The tumor-associated glycoprotein osteopontin (OPN) is discussed as a plasma surrogate marker of tumor hypoxia and as an indicator of the presence of pleural mesothelioma in asbestos-exposed individuals. The clinical introduction of plasma OPN measurements requires the availability of a reliable enzyme-linked immunosorbence assay (ELISA). We compared previously described and currently available ELISA systems on 88 archival plasma samples obtained from patients with head and neck or cervix cancer between 20 days before and 171 after the start of radiotherapy. Median (range) plasma OPN levels were 667 (148.8-2095) ng/ml and 9.8 (3.5-189.5) ng/ml for a previously described and a newly marketed assay, respectively. Although results for different assays were significantly correlated (r = 0.38, p < 0.05, Spearman rank test), between-assay factors ranged from 2.0 to 217.9 (median 74.6) in individual patients. OPN levels in cervix cancer patients were comparable to those of head and neck cancer patients. Commercially available OPN ELISA systems produce different absolute plasma OPN levels, compromising a comparison of individual patient data with published results. However, different assays appear to have a similar capacity to rank patients according to plasma OPN level. A review of literature data suggests that plasma OPN levels measured even with identical ELISA systems can only be compared with caution.

  5. Enzyme-linked immunosorbent assay detection and bioactivity of Cry1Ab protein fragments

    USDA-ARS?s Scientific Manuscript database

    Enzyme-linked immunosorbent assay (ELISA) has emerged as the preferred detection method for Cry proteins in environmental matrices. Concerns exist that ELISAs are capable of detecting fragments of Cry proteins, which may lead to an over-estimation of the concentration of these proteins in the enviro...

  6. A review of Cry protein detection with enzyme-linked immunosorbent assays

    USDA-ARS?s Scientific Manuscript database

    Several detection methods are available to monitor the fate of Cry proteins in the environment, enzyme-linked immunosorbent assays (ELISAs) have emerged as the preferred detection method, due to their cost-effectiveness, ease of use, and rapid results. Validation of ELISAs is necessary to ensure acc...

  7. Environmental Technology Verification Report for Abraxis Ecologenia® 17β-Estradiol (E2) Microplate Enzyme-Linked Immunosorbent Assay (ELISA) Test Kits

    EPA Science Inventory

    This verification test was conducted according to procedures specifiedin the Test/QA Planfor Verification of Enzyme-Linked Immunosorbent Assay (ELISA) Test Kis for the Quantitative Determination of Endocrine Disrupting Compounds (EDCs) in Aqueous Phase Samples. Deviations to the...

  8. Implementation of an Enzyme Linked Immunosorbent Assay for the Quantification of Allergenic Egg Residues in Red Wines Using Commercially Available Antibodies

    PubMed Central

    Koestel, Carole; Simonin, Céline; Belcher, Sandrine

    2016-01-01

    Abstract Since the early 2000s, labeling of potentially allergenic food components to protect people who suffer from food allergies is compulsory in numerous industrialized countries. In Europe, milk and egg components used during the winemaking process must be indicated on the label since July 1, 2012. Several ELISA procedures have been developed to detect allergenic residues in wines. However, the complexity of the wine matrix can inhibit the immunoenzymatic reaction. The aim of this study was to implement an ELISA assay for the detection of ovalbumin in red wines using commercially available antibodies. The specificity of the acquired antibodies and the absence of cross reactivity were assessed by immunoblotting and ELISA. An ELISA assay with a LOD of 14.2 μg/L and a LOQ of 56.4 μg/L of ovalbumin in aqueous solution was obtained. Differences in ELISA signals were observed when analyzing various fining agents, although reproducible conformation of the antigen could be reached for the comparison of ovalbumin and Ovicolle. The differences between samples in terms of pH could be leveled but the inhibition of the ELISA signal, positively correlated to the tannin content of the wines, could not be suppressed. Thus, standard curves of ovalbumin in several wines were obtained by relative quantification. The control steps and the difficulties encountered presented in this study should be considered by anybody working toward the development of ELISA assays for the detection of allergenic residues in complex food matrices. PMID:27356183

  9. Development of an Enzyme-Linked Immunosorbent Assay Based on Fusion VP2332-452 Antigen for Detecting Antibodies against Aleutian Mink Disease Virus.

    PubMed

    Chen, Xiaowei; Song, Cailing; Liu, Yun; Qu, Liandong; Liu, Dafei; Zhang, Yun; Liu, Ming

    2016-02-01

    For detection of Aleutian mink disease virus (AMDV) antibodies, an enzyme-linked immunosorbent assay (ELISA) was developed using the recombinant VP2332-452 protein as an antigen. Counterimmunoelectrophoresis (CIEP) was used as a reference test to compare the results of the ELISA and Western blotting (WB); the specificity and sensitivity of the VP2332-452 ELISA were 97.9% and 97.3%, respectively, which were higher than those of WB. Therefore, this VP2332-452 ELISA may be a preferable method for detecting antibodies against AMDV. Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  10. Enzyme-linked immunosorbent assay compared with neutralization tests for evaluation of live mumps vaccines.

    PubMed Central

    Sakata, H; Hishiyama, M; Sugiura, A

    1984-01-01

    Mumps-specific antibody levels before and after vaccination with live mumps vaccines were determined by enzyme-linked immunosorbent assay (ELISA) and neutralization tests. A correlation was found between neutralization titers and optical density in ELISA. However, postvaccination sera from some vaccinees who failed to seroconvert by neutralization contained significant levels of mumps-specific antibody detectable by ELISA. In some of these serum specimens, the antibody directed to the F polypeptide of mumps virus was predominant. Most sera positive in ELISA neutralized mumps virus upon the addition of fresh guinea pig serum to the virus-serum mixture. Images PMID:6361060

  11. Development of a Quantitative Sandwich Enzyme-Linked Immunosorbent Assay for Detecting the MPT64 Antigen of Mycobacterium tuberculosis

    PubMed Central

    Ji, Mijung; Cho, Byungki; Cho, Young Shik; Park, Song-Yong; Cho, Sang-Nae

    2014-01-01

    Purpose Tuberculosis (TB) is a major infectious disease and is responsible for two million deaths annually. For the identification and quantitation of Mycobacterium tuberculosis (M. tuberculosis), a causative agent of TB, a sandwich enzyme-linked immunosorbent assay (ELISA) against the MPT64 protein of M. tuberculosis, an antigen marker of the M. tuberculosis complex, was developed. Materials and Methods The MPT64 protein was expressed, and anti-MPT64 monoclonal antibodies were prepared. A sandwich ELISA was established using recombinant MPT64 protein and anti-MPT64 monoclonal antibodies. The sandwich MPT64 ELISA was evaluated using reference and clinical mycobacterial strains. Results The sandwich MPT64 ELISA detected MPT64 protein from 2.1 ng/mL to 250 ng/mL (equivalent to 1.7×104 CFU/mL and 2.0×106 CFU/mL). All 389 clinical M. tuberculosis isolates tested positive in the sandwich MPT64 ELISA (sensitivity, 100%), and the assay showed no cross reactivity to any tested nontuberculous mycobacterial strain (specificity, 100%). Conclusion The sandwich MPT64 ELISA is a highly sensitive and quantitative test for MPT64 protein, which can identify M. tuberculosis. PMID:24719143

  12. Multi-analyte validation in heterogeneous solution by ELISA.

    PubMed

    Lakshmipriya, Thangavel; Gopinath, Subash C B; Hashim, Uda; Murugaiyah, Vikneswaran

    2017-12-01

    Enzyme Linked Immunosorbent Assay (ELISA) is a standard assay that has been used widely to validate the presence of analyte in the solution. With the advancement of ELISA, different strategies have shown and became a suitable immunoassay for a wide range of analytes. Herein, we attempted to provide additional evidence with ELISA, to show its suitability for multi-analyte detection. To demonstrate, three clinically relevant targets have been chosen, which include 16kDa protein from Mycobacterium tuberculosis, human blood clotting Factor IXa and a tumour marker Squamous Cell Carcinoma antigen. Indeed, we adapted the routine steps from the conventional ELISA to validate the occurrence of analytes both in homogeneous and heterogeneous solutions. With the homogeneous and heterogeneous solutions, we could attain the sensitivity of 2, 8 and 1nM for the targets 16kDa protein, FIXa and SSC antigen, respectively. Further, the specific multi-analyte validations were evidenced with the similar sensitivities in the presence of human serum. ELISA assay in this study has proven its applicability for the genuine multiple target validation in the heterogeneous solution, can be followed for other target validations. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Development of a quantitative sandwich enzyme-linked immunosorbent assay for detecting the MPT64 antigen of Mycobacterium tuberculosis.

    PubMed

    Ji, Mijung; Cho, Byungki; Cho, Young Shik; Park, Song-Yong; Cho, Sang-Nae; Jeon, Bo-Young; Yoon, Byoung-Su

    2014-05-01

    Tuberculosis (TB) is a major infectious disease and is responsible for two million deaths annually. For the identification and quantitation of Mycobacterium tuberculosis (M. tuberculosis), a causative agent of TB, a sandwich enzyme-linked immunosorbent assay (ELISA) against the MPT64 protein of M. tuberculosis, an antigen marker of the M. tuberculosis complex, was developed. The MPT64 protein was expressed, and anti-MPT64 monoclonal antibodies were prepared. A sandwich ELISA was established using recombinant MPT64 protein and anti-MPT64 monoclonal antibodies. The sandwich MPT64 ELISA was evaluated using reference and clinical mycobacterial strains. The sandwich MPT64 ELISA detected MPT64 protein from 2.1 ng/mL to 250 ng/mL (equivalent to 1.7×10⁴ CFU/mL and 2.0×10⁶ CFU/mL). All 389 clinical M. tuberculosis isolates tested positive in the sandwich MPT64 ELISA (sensitivity, 100%), and the assay showed no cross reactivity to any tested nontuberculous mycobacterial strain (specificity, 100%). The sandwich MPT64 ELISA is a highly sensitive and quantitative test for MPT64 protein, which can identify M. tuberculosis.

  14. Molecular biological identification of Babesia, Theileria, and Anaplasma species in cattle in Egypt using PCR assays, gene sequence analysis and a novel DNA microarray.

    PubMed

    El-Ashker, Maged; Hotzel, Helmut; Gwida, Mayada; El-Beskawy, Mohamed; Silaghi, Cornelia; Tomaso, Herbert

    2015-01-30

    In this preliminary study, a novel DNA microarray system was tested for the diagnosis of bovine piroplasmosis and anaplasmosis in comparison with microscopy and PCR assay results. In the Dakahlia Governorate, Egypt, 164 cattle were investigated for the presence of piroplasms and Anaplasma species. All investigated cattle were clinically examined. Blood samples were screened for the presence of blood parasites using microscopy and PCR assays. Seventy-one animals were acutely ill, whereas 93 were apparently healthy. In acutely ill cattle, Babesia/Theileria species (n=11) and Anaplasma marginale (n=10) were detected. Mixed infections with Babesia/Theileria spp. and A. marginale were present in two further cases. A. marginale infections were also detected in apparently healthy subjects (n=23). The results of PCR assays were confirmed by DNA sequencing. All samples that were positive by PCR for Babesia/Theileria spp. gave also positive results in the microarray analysis. The microarray chips identified Babesia bovis (n=12) and Babesia bigemina (n=2). Cattle with babesiosis were likely to have hemoglobinuria and nervous signs when compared to those with anaplasmosis that frequently had bloody feces. We conclude that clinical examination in combination with microscopy are still very useful in diagnosing acute cases of babesiosis and anaplasmosis, but a combination of molecular biological diagnostic assays will detect even asymptomatic carriers. In perspective, parallel detection of Babesia/Theileria spp. and A. marginale infections using a single microarray system will be a valuable improvement. Copyright © 2015 The Authors. Published by Elsevier B.V. All rights reserved.

  15. Ultrasensitive Hybridization-Based ELISA Method for the Determination of Phosphorodiamidate Morpholino Oligonucleotides in Biological samples.

    PubMed

    Burki, Umar; Straub, Volker

    2017-01-01

    Determining the concentration of oligonucleotide in biological samples such as tissue lysate and serum is essential for determining the biodistribution and pharmacokinetic profile, respectively. ELISA-based assays have shown far greater sensitivities compared to other methods such as HPLC and LC/MS. Here, we describe a novel ultrasensitive hybridization-based ELISA method for quantitating morpholino oligonucleotides in mouse tissue lysate and serum samples. The assay has a linear detection range of 5-250 pM (R2 > 0.99).

  16. Novel fluorescent probe for highly sensitive bioassay using sequential enzyme-linked immunosorbent assay-capillary isoelectric focusing (ELISA-cIEF).

    PubMed

    Henares, Terence G; Uenoyama, Yuta; Nogawa, Yuto; Ikegami, Ken; Citterio, Daniel; Suzuki, Koji; Funano, Shun-ichi; Sueyoshi, Kenji; Endo, Tatsuro; Hisamoto, Hideaki

    2013-06-07

    This paper presents a novel rhodamine diphosphate molecule that allows highly sensitive detection of proteins by employing sequential enzyme-linked immunosorbent assay and capillary isoelectric focusing (ELISA-cIEF). Seven-fold improvement in the immunoassay sensitivity and a 1-2 order of magnitude lower detection limit has been demonstrated by taking advantage of the combination of the enzyme-based signal amplification of ELISA and the concentration of enzyme reaction products by cIEF.

  17. Performance Evaluation of Protein Chip Assay for Rapid Diagnosis of Hepatitis C Virus Infection in Injection Drug Abusers.

    PubMed

    Dai, Zhiyan; Shu, Xin; Li, Gang; Xi, Weidong

    2018-04-01

    We evaluated the performance of a protein chip assay for the detection of antibodies to hepatitis C virus (HCV) peptides among injection drug abusers (IDAs) by comparing the assay with existing methods, including enzyme-linked immunosorbent assay (ELISA), reverse transcription-polymerase chain reaction (RT-PCR), and recombinant immunoblot assay (RIBA). Seventy serum samples collected from IDAs were analyzed by protein chip assay. ELISA, RT-PCR, and RIBA assay were used to validate the results. The protein chips could detect different peptides' antibodies against HCV-C, HCV-NS3, HCV-NS4, HCV-NS5, and HCV-mix antigen; no cross reactivity between antigens was observed. Results of the protein-chip assay were compared with those of ELISA. Any inconsistency in results was validated by both RT-PCR and RIBA. Concordance between the results of the protein-chip assay and ELISA was 96.3% for positive samples and 100% for negative samples. The protein chip had a higher specificity than ELISA, a higher sensitivity than RTPCR, and similar specificity and sensitivity as compared to RIBA. The limit of detection of HCV antibodies in the protein chip assay was examined and calculated by incubation of model array with different dilutions. The protein chip assay required smaller amounts of both samples and reagents; it detected serum antibody in sample quantity as low as 3 ng/mL and at antibody dilution as low as 1:1000; its cost was low as well. The positive rates in the antiC, anti-NS3, anti-NS4, and anti-NS5 groups were significantly associated with levels of HCV RNA and the viral load. The HCV RNA and protein chip positive rate in the injection equipment-sharing group was higher than that in the non-injection equipment-sharing group. The protein chip assay is a faster and simpler approach to simultaneously screen for all HCV peptide antibodies accurately and to provide a rapid diagnosis of HCV infection in IDAs. The dominant positive HCV peptide antibodies were significantly associated with HCV RNA load, especially in the injection equipment-sharing group.

  18. Performance Evaluation of a Novel Chemiluminescence Assay Detecting Treponema Pallidum Antibody as a Syphilis Screening Method.

    PubMed

    Chen, Qixia; An, Jingna; Rao, Chenli; Wang, Tingting; Li, Dongdong; Feng, Shu; Tao, Chuanmin

    2016-01-01

    Syphilis is a major concern to global public health with increasing incidence. So its screening test should have sufficient sensitivity and specificity. We evaluated the performance of the Lumipulse G TP-N assay detection for syphilis screening and compared it with the InTec ELISA test kit for TP, which is widely used. Samples of several patient groups including 133 clinical and serologically characterized syphilitic sera, 175 samples containing potentially interfering agents, and 2290 unselected samples submitted for routine screening were detected by both the Lumipulse G TP-N assay and the InTec ELISA test kit for TP. Inconsistent samples were confirmed by RecomLine Treponema IgG, IgM immunoblot. Coefficient of variations of the Lumipulseo G TP-N assay at both levels were below 5% and of the InTec ELISA test kit for TP both over 5%. The sensitivity of the Lumipulse G TP-N assay and the InTec ELISA test kit for TP were 100% for all stages of syphilis. The two methods had consistent analytical specificity of 100% (95% CI: 97.21 - 100.00), while the clinical specificity was 100% (95% CI: 99.79 - 100.00) and 99.82% (95% CI: 99.51 - 99.94), respectively. Between them, Spearman's correlation coefficient was 0.455 and kappa value was 0.986. The overall sensitivity and specificity of the Lumipulse G TP-N assay was higher than the InTec ELISA test kit for TP (sensitivity: 100.0 versus 99.5, specificity: 100.0 versus 99.8). The automated Lumipulse G TP-N assay demonstrated excellent diagnostic sensitivity and specificity when evaluated as a screening test for syphilis. Thus, it can be an alternative to the treponemal screening test.

  19. Analytical validation of a reference laboratory ELISA for the detection of feline leukemia virus p27 antigen.

    PubMed

    Buch, Jesse S; Clark, Genevieve H; Cahill, Roberta; Thatcher, Brendon; Smith, Peter; Chandrashekar, Ramaswamy; Leutenegger, Christian M; O'Connor, Thomas P; Beall, Melissa J

    2017-09-01

    Feline leukemia virus (FeLV) is an oncogenic retrovirus of cats. Immunoassays for the p27 core protein of FeLV aid in the detection of FeLV infections. Commercial microtiter-plate ELISAs have rapid protocols and visual result interpretation, limiting their usefulness in high-throughput situations. The purpose of our study was to validate the PetChek FeLV 15 ELISA, which is designed for the reference laboratory, and incorporates sequential, orthogonal screening and confirmatory protocols. A cutoff for the screening assay was established with 100% accuracy using 309 feline samples (244 negative, 65 positive) defined by the combined results of FeLV PCR and an independent reference p27 antigen ELISA. Precision of the screening assay was measured using a panel of 3 samples (negative, low-positive, and high-positive). The intra-assay coefficient of variation (CV) was 3.9-7.9%; the inter-assay CV was 6.0-8.6%. For the confirmatory assay, the intra-assay CV was 3.0-4.7%, and the inter-assay CV was 7.4-9.7%. The analytical sensitivity for p27 antigen was 3.7 ng/mL for inactivated whole FeLV and 1.2 ng/mL for purified recombinant FeLV p27. Analytical specificity was demonstrated based on the absence of cross-reactivity to related retroviruses. No interference was observed for samples containing added bilirubin, hemoglobin, or lipids. Based on these results, the new high-throughput design of the PetChek FeLV 15 ELISA makes it suitable for use in reference laboratory settings and maintains overall analytical performance.

  20. Optimization and Validation of ELISA for Pre-Clinical Trials of Influenza Vaccine.

    PubMed

    Mitic, K; Muhandes, L; Minic, R; Petrusic, V; Zivkovic, I

    2016-01-01

    Testing of every new vaccine involves investigation of its immunogenicity, which is based on monitoring its ability to induce specific antibodies in animals. The fastest and most sensitive method used for this purpose is enzyme-linked immunosorbent assay (ELISA). However, commercial ELISA kits with whole influenza virus antigens are not available on the market, and it is therefore essential to establish an adequate assay for testing influenza virusspecific antibodies. We developed ELISA with whole influenza virus strains for the season 2011/2012 as antigens and validated it by checking its specificity, accuracy, linearity, range, precision, and sensitivity. The results show that we developed high-quality ELISA that can be used to test immunogenicity of newly produced seasonal or pandemic vaccines in mice. The pre-existence of validated ELISA enables shortening the time from the process of vaccine production to its use in patients, which is particularly important in the case of a pandemic.

  1. Effective surveillance for early classical swine fever virus detection will utilize both virus and antibody detection capabilities.

    PubMed

    Panyasing, Yaowalak; Kedkovid, Roongtham; Thanawongnuwech, Roongroje; Kittawornrat, Apisit; Ji, Ju; Giménez-Lirola, Luis; Zimmerman, Jeffrey

    2018-03-01

    Early recognition and rapid elimination of infected animals is key to controlling incursions of classical swine fever virus (CSFV). In this study, the diagnostic characteristics of 10 CSFV assays were evaluated using individual serum (n = 601) and/or oral fluid (n = 1417) samples collected from -14 to 28 days post inoculation (DPI). Serum samples were assayed by virus isolation (VI), 2 commercial antigen-capture enzyme-linked immunosorbent assays (ELISA), virus neutralization (VN), and 3 antibody ELISAs. Both serum and oral fluid samples were tested with 3 commercial real-time reverse transcription-polymerase chain reaction (rRT-PCR) assays. One or more serum samples was positive by VI from DPIs 3 to 21 and by antigen-capture ELISAs from DPIs 6 to 17. VN-positive serum samples were observed at DPIs ≥ 7 and by antibody ELISAs at DPIs ≥ 10. CSFV RNA was detected in serum samples from DPIs 2 to 28 and in oral fluid samples from DPIs 4 to 28. Significant differences in assay performance were detected, but most importantly, no single combination of sample and assay was able to dependably identify CSFV-inoculated pigs throughout the 4-week course of the study. The results show that effective surveillance for CSFV, especially low virulence strains, will require the use of PCR-based assays for the detection of early infections (<14 days) and antibody-based assays, thereafter. Copyright © 2018 Elsevier B.V. All rights reserved.

  2. Usefulness of a single-assay chemiluminescence test (Tularaemia VIRCLIA IgG + IgM monotest) for the diagnosis of human tularemia. Comparison of five serological tests.

    PubMed

    Cubero, África; Durántez, Carlos; Almaraz, Ana; Fernández-Lago, Luis; Gutiérrez, María P; Castro, María J; Bratos, Miguel A; Simarro, María; March, Gabriel A; Orduña, Antonio

    2018-04-01

    The aim of this work was to ascertain the usefulness of a new commercially-available single-assay chemiluminescence test (CHT) for the diagnosis of human tularemia (Tularaemia VIRCLIA IgG + IgM monotest, Vircell, Santa Fe, Granada, Spain). A total of 773 sera from 773 patients including 364 initial sera from patients with diagnosed tularemia, patients with suspected tularemia not confirmed (100), healthy people (152), patients with serology positive to Brucella (97), patients diagnosed with other infectious diseases (30), and patients diagnosed with autoimmune diseases (30) were included. All sera were tested by CHT, "in-house" microagglutination test (MAT), immunochromatographic test (ICT) (Virapid Tularaemia, Vircell, Santa Fe Granada, Spain), and "in-house" ELISA IgG, and ELISA IgM. Of the total initial sera, 334 (sensitivity 91.8%) were positive in the CHT, 332 (sensitivity 91.2%) in the MAT, 330 (sensitivity 90.7%) in the ICT, and 328 (sensitivity 90.1%) in the ELISA IgG and ELISA IgM tests. The specificity of the CHT was 96.7%; of the MAT, 100%; of the ICT, 98.7%; and of the ELISA IgG and ELISA IgM, 97.4%. In the group of patients with serology positive to Brucella, at least 12.4% of sera were positive in tularemia tests (12.4% in ELISA IgM, 13.4% in MAT, 14.4% in ICT, and 15.5% in CHT and ELISA IgG). In conclusion, CHT presents a sensitivity and specificity in early diagnosis of human tularemia, similar to MAT, ICT, and ELISA IgG and ELISA IgM. Its single assay design allows lower costs, especially in areas of low endemicity or inter-epidemic periods.

  3. 75 FR 57200 - National Poultry Improvement Plan and Auxiliary Provisions

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-09-20

    ... (ELISA) test to confirm the positive results of other serological tests. We are proposing to remove the ELISA test from this list. The ELISA test is a screening assay and should not be used to confirm... status is negative for Mycoplasma. We would amend this paragraph to include the ELISA and the official...

  4. An improved method for undertaking limiting dilution assays for in vitro cloning of Plasmodium falciparum parasites.

    PubMed

    Butterworth, Alice S; Robertson, Alan J; Ho, Mei-Fong; Gatton, Michelle L; McCarthy, James S; Trenholme, Katharine R

    2011-04-18

    Obtaining single parasite clones is required for many techniques in malaria research. Cloning by limiting dilution using microscopy-based assessment for parasite growth is an arduous and labor-intensive process. An alternative method for the detection of parasite growth in limiting dilution assays is using a commercial ELISA histidine-rich protein II (HRP2) detection kit. Detection of parasite growth was undertaken using HRP2 ELISA and compared to thick film microscopy. An HRP2 protein standard was used to determine the detection threshold of the HRP2 ELISA assay, and a HRP2 release model was used to extrapolate the amount of parasite growth required for a positive result. The HRP2 ELISA was more sensitive than microscopy for detecting parasite growth. The minimum level of HRP2 protein detection of the ELISA was 0.11 ng/ml. Modeling of HRP2 release determined that 2,116 parasites are required to complete a full erythrocytic cycle to produce sufficient HRP2 to be detected by the ELISA. Under standard culture conditions this number of parasites is likely to be reached between 8 to 14 days of culture. This method provides an accurate and simple way for the detection of parasite growth in limiting dilution assays, reducing time and resources required in traditional methods. Furthermore the method uses spent culture media instead of the parasite-infected red blood cells, enabling culture to continue. © 2011 Butterworth et al; licensee BioMed Central Ltd.

  5. Recombinant Antigen-Based Enzyme-Linked Immunosorbent Assay for Diagnosis of Baylisascaris procyonis Larva Migrans ▿

    PubMed Central

    Dangoudoubiyam, Sriveny; Vemulapalli, Ramesh; Ndao, Momar; Kazacos, Kevin R.

    2011-01-01

    Baylisascaris larva migrans is an important zoonotic disease caused by Baylisascaris procyonis, the raccoon roundworm, and is being increasingly considered in the differential diagnosis of eosinophilic meningoencephalitis in children and young adults. Although a B. procyonis excretory-secretory (BPES) antigen-based enzyme-linked immunosorbent assay (ELISA) and a Western blot assay are useful in the immunodiagnosis of this infection, cross-reactivity remains a major problem. Recently, a recombinant B. procyonis antigen, BpRAG1, was reported for use in the development of improved serological assays for the diagnosis of Baylisascaris larva migrans. In this study, we tested a total of 384 human patient serum samples in a BpRAG1 ELISA, including samples from 20 patients with clinical Baylisascaris larva migrans, 137 patients with other parasitic infections (8 helminth and 4 protozoan), and 227 individuals with unknown/suspected parasitic infections. A sensitivity of 85% and a specificity of 86.9% were observed with the BpRAG1 ELISA, compared to only 39.4% specificity with the BPES ELISA. In addition, the BpRAG1 ELISA had a low degree of cross-reactivity with antibodies to Toxocara infection (25%), while the BPES antigen showed 90.6% cross-reactivity. Based on these results, the BpRAG1 antigen has a high degree of sensitivity and specificity and should be very useful and reliable in the diagnosis and seroepidemiology of Baylisascaris larva migrans by ELISA. PMID:21832102

  6. Sensitivity and specificity enhanced enzyme-linked immunosorbent assay by rational hapten modification and heterogeneous antibody/coating antigen combinations for the detection of melamine in milk, milk powder and feed samples.

    PubMed

    Cao, Biyun; Yang, Hong; Song, Juan; Chang, Huafang; Li, Shuqun; Deng, Anping

    2013-11-15

    The adulteration of food products with melamine has led to an urgent requirement for sensitive, specific, rapid and reliable quantitative/screening methods. To enhance the sensitivity and specificity of the enzyme-linked immunosorbent assay (ELISA) for the detection of melamine in milk, milk powder and feed samples, rational hapten modification and heterogeneous antibody/coating antigen combinations were adopted. Three melamine derivatives with different length of carboxylic spacer at the end were synthesized and linked to carrier proteins for the production of immunogens and coating antigens. Monoclonal antibody against melamine was produced by hybridoma technology. Under optimal experimental conditions, the standard curves of the ELISAs for melamine were constructed in range of 0.1-100 ng mL(-1). The sensitivity was 10-300 times enhanced compared to those in the published literatures. The cross-reactivity values of the ELISAs also demonstrated the assays exhibited high specificity. Five samples were spiked with melamine at different concentrations and detected by the ELISA. The recovery rates of 72.8-123.0% and intra-assay coefficients of variation of 0.8-18.9% (n=3) were obtained. The ELISA for milk sample was confirmed by high-performance liquid chromatography with a high correlation coefficient of 0.9902 (n=6). The proposed ELISA was proven to be a feasible quantitative/screening method for melamine analysis. Copyright © 2013 Elsevier B.V. All rights reserved.

  7. Epitope-blocking enzyme-linked immunosorbent assay for detection of antibodies to Ross River virus in vertebrate sera.

    PubMed

    Oliveira, Nidia M M; Broom, Annette K; Mackenzie, John S; Smith, David W; Lindsay, Michael D A; Kay, Brian H; Hall, Roy A

    2006-07-01

    We describe the development of an epitope-blocking enzyme-linked immunosorbent assay (ELISA) for the sensitive and rapid detection of antibodies to Ross River virus (RRV) in human sera and known vertebrate host species. This ELISA provides an alternative method for the serodiagnosis of RRV infections.

  8. A Direct, Competitive Enzyme-Linked Immunosorbent Assay (ELISA) as a Quantitative Technique for Small Molecules

    ERIC Educational Resources Information Center

    Powers, Jennifer L.; Rippe, Karen Duda; Imarhia, Kelly; Swift, Aileen; Scholten, Melanie; Islam, Naina

    2012-01-01

    ELISA (enzyme-linked immunosorbent assay) is a widely used technique with applications in disease diagnosis, detection of contaminated foods, and screening for drugs of abuse or environmental contaminants. However, published protocols with a focus on quantitative detection of small molecules designed for teaching laboratories are limited. A…

  9. Comparison of six commercial tick-borne encephalitis IgM and IgG ELISA kits and the molecular characterization of their antigenic design.

    PubMed

    Velay, Aurélie; Solis, Morgane; Barth, Heidi; Sohn, Véronique; Moncollin, Anne; Neeb, Amandine; Wendling, Marie-Josée; Fafi-Kremer, Samira

    2018-04-01

    Tick-borne encephalitis virus (TBEV) diagnosis is mainly based on the detection of viral-specific antibodies in serum. Several commercial assays are available, but published data on their performance remain unclear. We assessed six IgM and six IgG commercial enzyme-linked immunosorbent assay (ELISA) kits (ELISA-1 through ELISA-6) using 94 samples, including precharacterized TBEV-positive samples (n=50) and -negative samples (n=44). The six manufacturers showed satisfactory sensitivity and specificity and high overall agreement for both IgM and IgG. Three manufacturers showed better reproducibility and were the most sensitive (100%) and specific (95.5-98.1%) for both IgM and IgG. Two of them were also in agreement with the clinical interpretation in more than 90% of the cases. All the assays use inactivated virus as antigen, with strains showing approximately 94% homology at the amino acid level. The antigenic format of the assays was discussed to further improve this TBEV diagnostic tool. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. A novel modified-indirect ELISA based on spherical body protein 4 for detecting antibody during acute and long-term infections with diverse Babesia bovis strains.

    PubMed

    Chung, Chungwon J; Suarez, Carlos E; Bandaranayaka-Mudiyanselage, Carey L; Bandaranayaka-Mudiyanselage, Chandima-Bandara; Rzepka, Joanna; Heiniger, T J; Chung, Grace; Lee, Stephen S; Adams, Ethan; Yun, Grace; Waldron, Susan J

    2017-02-13

    Cattle persistently infected with Babesia bovis are reservoirs for intra- and inter-herd transmission. Since B. bovis is considered a persistent infection, developing a reliable, high-throughput assay that detects antibody during all stages of the infection could be pivotal for establishing better control protocols. A modified indirect enzyme-linked immunosorbent assay (MI-ELISA) was developed using the spherical body protein-4 (SBP4) of B. bovis to detect antibody against diverse strains through all infection stages in cattle. This SBP4 MI-ELISA was evaluated for sensitivity and specificity against field sera from regions with endemic and non-endemic B. bovis. Sera were also evaluated from cattle infected experimentally with various doses and strains during acute and persistent infection with parasitemia defined by nested PCR. The format variables for SBP4 MI-ELISA were optimized and the cutoff for positive and negative interpretation was determined based on receiver operating characteristic curve analysis using B. bovis positive and negative sera tested in the reference immunofluorescence assay (IFA). The diagnostic specificity of the SBP4 MI-ELISA using IFA-negative sera collected from Texas was 100%, significantly higher than the cELISA (90.4%) based on an epitope in the rhoptry-associated protein-1 (RAP-1 cELISA). The diagnostic sensitivity of the SBP4 MI-ELISA was 98.7% using the IFA-positive sera collected from several areas of Mexico, in contrast to that of the RAP-1 cELISA at 60% using these same sera. In cattle infected with low and high doses of three B. bovis strains, the SBP4 MI-ELISA remained antibody positive for 11 months or more after initial detection at 10 to 13 days post-inoculation. However, the RAP-1 cELISA did not reliably detect antibody after eight months post-inoculation despite the fact that parasitemia was occasionally detectable by PCR. Furthermore, initial antibody detection by RAP-1 cELISA in low-dose infected animals was delayed approximately nine and a half days compared to the SBP4 MI-ELISA. These results demonstrate excellent diagnostic sensitivity and specificity of the novel SBP4 MI-ELISA for cattle with acute and long-term carrier infections. It is posited that use of this assay in countries that have B. bovis-endemic herds may be pivotal in preventing the spread of this disease to non-endemic herds.

  11. Development of an ELISA to detect circulating anti-asparaginase antibodies in dogs with lymphoid neoplasia treated with Escherichia coli l-asparaginase.

    PubMed

    Kidd, J A; Ross, P; Buntzman, A S; Hess, P R

    2015-06-01

    Resistance to Escherichia coli l-asparaginase in canine lymphoma occurs frequently with repeated administration, a phenomenon often attributed, without substantiation, to the induction of neutralizing antibodies. To test the hypothesis that treated dogs develop antibodies against the drug, we created an enzyme-linked immunosorbent assay (ELISA) to measure plasma anti-asparaginase immunoglobulin G responses. Using samples from dogs that had received multiple doses, specific reactivity against l-asparaginase was demonstrated, while naïve patients' samples were negative. The optimized ELISA appeared sensitive, with endpoint titers >1 600 000 in positive control dogs. Intra- and inter-assay coefficients of variation were 3.6 and 14.5%. The assay was supported by the observation that ELISA-positive plasma could immunoprecipitate asparaginase activity. When clinical patients were evaluated, 3/10 dogs developed titers after a single injection; with repeated administration, 4/7 dogs were positive. l-asparaginase antibodies showed reduced binding to the PEGylated drug formulation. The ELISA should prove useful in investigating the potential correlation of antibody responses with resistance. © 2012 Blackwell Publishing Ltd.

  12. Enzyme-linked immunosorbent assays for determination of plasma aldosterone using highly specific polyclonal antibodies.

    PubMed

    Schwartz, F; Hadas, E; Harnik, M; Solomon, B

    1990-01-01

    Two enzyme-linked immunosorbent assays were established and compared for the estimation of plasma aldosterone. In the first method immobilized aldosterone-protein complexes on the ELISA plates compete with aldosterone to be determined for the binding of certain amount of anti-aldosterone antibodies. The sensitivity of this method depends on the protein carrier used to conjugate with aldosterone. In the second method, anti-aldosterone antibodies adsorbed on ELISA plates compete for binding of known amount of the enzyme-labeled aldosterone and aldosterone to be determined. The highly specific rabbit anti-aldosterone antibodies were obtained by injection of aldosterone-oxime thyroglobulin. The detection limit of aldosterone in both methods ranged between 2-20 pg. The proposed assays are suitable for the determination of aldosterone in biological fluids compared with other reported ELISA assays, as well as with RIA.

  13. Monoclonal antibodies against colonization factor antigen I pili from enterotoxigenic Escherichia coli.

    PubMed

    Worobec, E A; Shastry, P; Smart, W; Bradley, R; Singh, B; Paranchych, W

    1983-09-01

    Hybridomas secreting monoclonal antibodies directed against intact colonization factor antigen I pili have been produced by the fusion of spleen cells from immunized BALB/c mice with NS1/SP2 myeloma cells. The four monoclones with the highest antibody titer, as detected by enzyme-linked immunosorbant assay (ELISA), were chosen for antibody amplification by production of mouse ascitic fluid. These four were examined for antibody specificity by ELISA and immunoblot assays, using six different pilus types. Three of the four monoclonal isolates were specific for only colonization factor antigen I pili in both assays, whereas the remaining isolate showed a distinct cross-reactivity with K99 pili in the ELISA assay but not in immunoblot analysis. These results indicate that this monoclone may be recognizing a common structural element between the two adhesive pilus types.

  14. Monoclonal antibodies against colonization factor antigen I pili from enterotoxigenic Escherichia coli.

    PubMed Central

    Worobec, E A; Shastry, P; Smart, W; Bradley, R; Singh, B; Paranchych, W

    1983-01-01

    Hybridomas secreting monoclonal antibodies directed against intact colonization factor antigen I pili have been produced by the fusion of spleen cells from immunized BALB/c mice with NS1/SP2 myeloma cells. The four monoclones with the highest antibody titer, as detected by enzyme-linked immunosorbant assay (ELISA), were chosen for antibody amplification by production of mouse ascitic fluid. These four were examined for antibody specificity by ELISA and immunoblot assays, using six different pilus types. Three of the four monoclonal isolates were specific for only colonization factor antigen I pili in both assays, whereas the remaining isolate showed a distinct cross-reactivity with K99 pili in the ELISA assay but not in immunoblot analysis. These results indicate that this monoclone may be recognizing a common structural element between the two adhesive pilus types. Images PMID:6136463

  15. Clinical Utility of an Enzyme-Linked Immunosorbent Assay for Detecting Anti-Melanoma Differentiation-Associated Gene 5 Autoantibodies

    PubMed Central

    Sato, Shinji; Murakami, Akihiro; Kuwajima, Akiko; Takehara, Kazuhiko; Mimori, Tsuneyo; Kawakami, Atsushi; Mishima, Michiaki; Suda, Takafumi; Seishima, Mariko; Fujimoto, Manabu; Kuwana, Masataka

    2016-01-01

    Objective Autoantibodies to melanoma differentiation-associated gene 5 (MDA5) are specifically expressed in patients with dermatomyositis (DM) and are associated with a subset of DM patients with rapidly progressive interstitial lung disease (RP-ILD). Here, we examined the clinical utility of a newly developed enzyme-linked immunosorbent assay (ELISA) system for detecting these antibodies. Methods Here we developed an improved ELISA for detecting anti-MDA5 antibodies. We then performed a multicenter clinical study involving 8 medical centers and enrolled 242 adult patients with polymyositis (PM)/DM, 190 with non-PM/DM connective tissue disease (CTD), 154 with idiopathic interstitial pneumonia (IIP), and 123 healthy controls. Anti-MDA5 antibodies in the patients’ serum samples were quantified using our newly developed ELISA, and the results were compared to those obtained using the gold-standard immunoprecipitation (IP) assay. In addition, correlations between the ELISA-quantified anti-MDA5 antibodies and clinical characteristics were evaluated. Results In patients with PM/DM, the anti-MDA5 antibody measurements obtained from the ELISA and IP assay were highly concordant; the ELISA exhibited an analytical sensitivity of 98.2%, specificity of 100%, positive predictive value of 100%, and negative predictive value of 99.5% (compared to the IP assay). Anti-MDA5 antibodies were detected in 22.7% of the DM patients, but not in any of the patients with PM, non-PM/DM CTD, or IIP. Clinically amyopathic DM, RP-ILD, arthritis, and fever were more prevalent in DM patients who were anti-MDA5 antibody-positive than in those who were antibody-negative (P ≤ 0.0002 for all comparisons). In addition, anti-MDA5 antibody-positive patients with RP-ILD exhibited higher antibody levels than those without RP-ILD (P = 0.006). Conclusion Our newly developed ELISA can detect anti-MDA5 antibodies as efficiently as the gold standard IP assay and has the potential to facilitate the routine clinical measurement of anti-MDA5 antibodies in patients who suspected to have DM. PMID:27115353

  16. Clinical Utility of an Enzyme-Linked Immunosorbent Assay for Detecting Anti-Melanoma Differentiation-Associated Gene 5 Autoantibodies.

    PubMed

    Sato, Shinji; Murakami, Akihiro; Kuwajima, Akiko; Takehara, Kazuhiko; Mimori, Tsuneyo; Kawakami, Atsushi; Mishima, Michiaki; Suda, Takafumi; Seishima, Mariko; Fujimoto, Manabu; Kuwana, Masataka

    2016-01-01

    Autoantibodies to melanoma differentiation-associated gene 5 (MDA5) are specifically expressed in patients with dermatomyositis (DM) and are associated with a subset of DM patients with rapidly progressive interstitial lung disease (RP-ILD). Here, we examined the clinical utility of a newly developed enzyme-linked immunosorbent assay (ELISA) system for detecting these antibodies. Here we developed an improved ELISA for detecting anti-MDA5 antibodies. We then performed a multicenter clinical study involving 8 medical centers and enrolled 242 adult patients with polymyositis (PM)/DM, 190 with non-PM/DM connective tissue disease (CTD), 154 with idiopathic interstitial pneumonia (IIP), and 123 healthy controls. Anti-MDA5 antibodies in the patients' serum samples were quantified using our newly developed ELISA, and the results were compared to those obtained using the gold-standard immunoprecipitation (IP) assay. In addition, correlations between the ELISA-quantified anti-MDA5 antibodies and clinical characteristics were evaluated. In patients with PM/DM, the anti-MDA5 antibody measurements obtained from the ELISA and IP assay were highly concordant; the ELISA exhibited an analytical sensitivity of 98.2%, specificity of 100%, positive predictive value of 100%, and negative predictive value of 99.5% (compared to the IP assay). Anti-MDA5 antibodies were detected in 22.7% of the DM patients, but not in any of the patients with PM, non-PM/DM CTD, or IIP. Clinically amyopathic DM, RP-ILD, arthritis, and fever were more prevalent in DM patients who were anti-MDA5 antibody-positive than in those who were antibody-negative (P ≤ 0.0002 for all comparisons). In addition, anti-MDA5 antibody-positive patients with RP-ILD exhibited higher antibody levels than those without RP-ILD (P = 0.006). Our newly developed ELISA can detect anti-MDA5 antibodies as efficiently as the gold standard IP assay and has the potential to facilitate the routine clinical measurement of anti-MDA5 antibodies in patients who suspected to have DM.

  17. A DNA microarray-based assay to detect dual infection with two dengue virus serotypes.

    PubMed

    Díaz-Badillo, Alvaro; Muñoz, María de Lourdes; Perez-Ramirez, Gerardo; Altuzar, Victor; Burgueño, Juan; Mendoza-Alvarez, Julio G; Martínez-Muñoz, Jorge P; Cisneros, Alejandro; Navarrete-Espinosa, Joel; Sanchez-Sinencio, Feliciano

    2014-04-25

    Here; we have described and tested a microarray based-method for the screening of dengue virus (DENV) serotypes. This DNA microarray assay is specific and sensitive and can detect dual infections with two dengue virus serotypes and single-serotype infections. Other methodologies may underestimate samples containing more than one serotype. This technology can be used to discriminate between the four DENV serotypes. Single-stranded DNA targets were covalently attached to glass slides and hybridised with specific labelled probes. DENV isolates and dengue samples were used to evaluate microarray performance. Our results demonstrate that the probes hybridized specifically to DENV serotypes; with no detection of unspecific signals. This finding provides evidence that specific probes can effectively identify single and double infections in DENV samples.

  18. A DNA Microarray-Based Assay to Detect Dual Infection with Two Dengue Virus Serotypes

    PubMed Central

    Díaz-Badillo, Alvaro; de Lourdes Muñoz, María; Perez-Ramirez, Gerardo; Altuzar, Victor; Burgueño, Juan; Mendoza-Alvarez, Julio G.; Martínez-Muñoz, Jorge P.; Cisneros, Alejandro; Navarrete-Espinosa, Joel; Sanchez-Sinencio, Feliciano

    2014-01-01

    Here; we have described and tested a microarray based-method for the screening of dengue virus (DENV) serotypes. This DNA microarray assay is specific and sensitive and can detect dual infections with two dengue virus serotypes and single-serotype infections. Other methodologies may underestimate samples containing more than one serotype. This technology can be used to discriminate between the four DENV serotypes. Single-stranded DNA targets were covalently attached to glass slides and hybridised with specific labelled probes. DENV isolates and dengue samples were used to evaluate microarray performance. Our results demonstrate that the probes hybridized specifically to DENV serotypes; with no detection of unspecific signals. This finding provides evidence that specific probes can effectively identify single and double infections in DENV samples. PMID:24776933

  19. Multipotent human stromal cells improve cardiac function after myocardial infarction in mice without long-term engraftment.

    PubMed Central

    Iso, Yoshitaka; Spees, Jeffrey L.; Serrano, Claudia; Bakondi, Benjamin; Pochampally, Radhika; Song, Yao-Hua; Sobel, Burton E.; Delafontaine, Patrick; Prockop, Darwin J.

    2007-01-01

    The aim of this study was to determine whether intravenously-administered multipotent stromal cells from human bone marrow (hMSCs) can improve cardiac function after myocardial infarction (MI) without long-term engraftment and therefore whether transitory paracrine effects or secreted factors are responsible for the benefit conferred. hMSCs were injected systemically into immunodeficient mice with acute MI. Cardiac function and fibrosis after MI in the hMSC-treated group was significantly improved compared with that in controls. However, despite the cardiac improvement, there was no evident hMSC engraftment in the heart 3 weeks after MI. Microarray assays and ELISAs demonstrated that multiple protective factors were expressed and secreted from the hMSCs in culture. Factors secreted by hMSCs prevented cell death of cultured cardiomyocytes and endothelial cells under conditions that mimicked tissue ischemia. The favorable effects of hMSCs appear to reflect the impact of secreted factors rather than engraftment, differentiation, or cell fusion. PMID:17257581

  20. Multiplex DNA detection of food allergens on a digital versatile disk.

    PubMed

    Tortajada-Genaro, Luis A; Santiago-Felipe, Sara; Morais, Sergi; Gabaldón, José Antonio; Puchades, Rosa; Maquieira, Ángel

    2012-01-11

    The development of a DNA microarray method on a digital versatile disk (DVD) is described for the simultaneous detection of traces of hazelnut ( Corylus avellana L.), peanut ( Arachis hypogaea ), and soybean ( Glycine max ) in foods. After DNA extraction, multiplex PCR was set up using 5'-labeled specific primers for Cor a 1, Ar h 2, and Le genes, respectively. Digoxin-labeled PCR products were detected by hybridization with 5'-biotinylated probes immobilized on a streptavidin-modified DVD surface. The reaction product attenuates the signal intensity of the laser that reached the DVD drive used as detector, correlating well with the amount of amplified sequence. Analytical performances showed a detection limit of 1 μg/g and good assay reproducibility (RSD 8%), suitable for the simultaneous detection of the three targeted allergens. The developed methodology was tested with several commercially available foodstuffs, demonstrating its applicability. The results were in good agreement, in terms of sensitivity and reproducibility, with those obtained with ELISA, PCR-gel agarose electrophoresis, and RT-PCR.

  1. Detection of Antibodies to the Biofilm Exopolysaccharide of Histophilus somni following Infection in Cattle by Enzyme-Linked Immunosorbent Assay

    PubMed Central

    Pan, Yu; Fisher, Taylor; Olk, Christina

    2014-01-01

    An enzyme-linked immunosorbent assay (ELISA) was developed to detect bovine antibodies to Histophilus somni exopolysaccharide (EPS), which is created during biofilm formation. When an index value of 0.268 was used, the sensitivity of the assay for infected calves was 90.5% at 3 weeks postinfection, but the number of positive animals increased by week 4. The specificity of the assay for healthy calves was 92.5%. The EPS ELISA may aid in identifying calves with H. somni diseases. PMID:25143338

  2. Using an enzyme linked immunosorbent assay (ELISA) and a protein phosphatase inhibition assay (PPIA) for the detection of microcystins and nodularins.

    PubMed

    Carmichael, W W; An, J

    1999-01-01

    Cyanotoxins produced by cyanobacteria (blue-green algae) include potent neurotoxins and hepatotoxins. The hepatotoxins include cyclic peptide microcystins and nodularins plus the alkaloid cylindrospermopsins. Among the cyanotoxins the microcystins have proven to be the most widespread, and are most often implicated in animal and human poisonings. This paper presents a practical guide to two widely used methods for detecting and quantifying microcystins and nodularins in environmental samples-the enzyme linked immunosorbant assay (ELISA) and the protein phosphatase inhibition assay (PPIA).

  3. [Assessment Method of Remnant α-1, 3-galactosyle Epitopes in Animal Tissue-derived Biomaterials].

    PubMed

    Shan, Yongqiang; Xu, Liming; Ke, Linnan; Lu, Yan; Shao, Anliang; Zhang, Na; Zeng, Bixin

    2015-06-01

    The aim of this study was to establish an assessment method for determining α-Gal (α-1, 3-galactosyle) epitopes contained in animal tissue or animal tissue-derived biological materials with ELISA inhibition assay. Firstly, a 96 well plate was coated with Gal α-1, 3-Gal/bovine serum albumin (BSA) as a solid phase antigen and meanwhile, the anti-α-Gal M86 was used to react with α-Gal antigens which contained in the test materials. Then, the residual antibodies (M86) in the supernatant of M86-Gal reaction mixture were measured using ELISA inhibition assay by the α-Gal coating plate. The inhibition curve of the ELISA inhibition assay, the R2 = 0.999, was well established. Checking using both α-Gal positive materials (rat liver tissues) and α-Gal negative materials (human placenta tissues) showed a good sensitivity and specificity. Based on the presently established method, the α-Gal expression profile of rat tissues, decellular animal tissue-derived biological materials and porcine dermal before and after decellular treatment were determined. The M86 ELISA inhibition assay method, which can quantitatively determine the α-Gal antigens contained in animal tissues or animal tissue-derived biomaterials, was refined. This M86 specific antibody based-ELISA inhibition assay established in the present study has good sensitivity and specificity, and could be a useful method for determining remnant α-1, 3Gal antigens in animal tissue-derived biomaterials.

  4. Synergistic Use of Gold Nanoparticles (AuNPs) and “Capillary Enzyme-Linked Immunosorbent Assay (ELISA)” for High Sensitivity and Fast Assays

    PubMed Central

    Kim, Wan-Joong; Cho, Hyo Young; Jeong, Bongjin; Byun, Sangwon; Huh, JaeDoo; Kim, Young Jun

    2017-01-01

    Using gold nanoparticles (AuNPs) on “capillary enzyme-linked immunosorbent assay (ELISA)”, we produced highly sensitive and rapid assays, which are the major attributes for point-of-care applications. First, in order to understand the size effect of AuNPs, AuNPs of varying diameters (5 nm, 10 nm, 15 nm, 20 nm, 30 nm, and 50 nm) conjugated with Horseradish Peroxidase (HRP)-labeled anti-C reactive protein (antiCRP) (AuNP•antiCRP-HRP) were used for well-plate ELISA. AuNP of 10 nm produced the largest optical density, enabling detection of 0.1 ng/mL of CRP with only 30 s of incubation, in contrast to 10 ng/mL for the ELISA run in the absence of AuNP. Then, AuNP of 10 nm conjugated with antiCRP-HRP (AuNP•antiCRP-HRP) was used for “capillary ELISA” to detect as low as 0.1 ng/mL of CRP. Also, kinetic study on both 96-well plates and in a capillary tube using antiCRP-HRP or AuNP•antiCRP-HRP showed a synergistic effect between AuNP and the capillary system, in which the fastest assay was observed from the “AuNP capillary ELISA”, with its maximum absorbance reaching 2.5 min, while the slowest was the typical well-plate ELISA with its maximum absorbance reaching in 13.5 min. PMID:29278402

  5. Development of a Microsphere-based Immunoassay for Serological Detection of African Horse Sickness Virus and Comparison with Other Diagnostic Techniques.

    PubMed

    Sánchez-Matamoros, A; Beck, C; Kukielka, D; Lecollinet, S; Blaise-Boisseau, S; Garnier, A; Rueda, P; Zientara, S; Sánchez-Vizcaíno, J M

    2016-12-01

    African horse sickness (AHS) is a viral disease that causes high morbidity and mortality rates in susceptible Equidae and therefore significant economic losses. More rapid, sensitive and specific assays are required by diagnostic laboratories to support effective surveillance programmes. A novel microsphere-based immunoassay (Luminex assay) in which beads are coated with recombinant AHS virus (AHSV) structural protein 7 (VP7) has been developed for serological detection of antibodies against VP7 of any AHSV serotype. The performance of this assay was compared with that of a commercial enzyme-linked immunosorbent assay (ELISA) and commercial lateral flow assay (LFA) on a large panel of serum samples from uninfected horses (n = 92), from a reference library of all AHSV serotypes (n = 9), on samples from horses experimentally infected with AHSV (n = 114), and on samples from West African horses suspected of having AHS (n = 85). The Luminex assay gave the same negative results as ELISA when used to test the samples from uninfected horses. Both assays detected antibodies to all nine AHSV serotypes. In contrast, the Luminex assay detected a higher rate of anti-VP7 positivity in the West African field samples than did ELISA or LFA. The Luminex assay detected anti-VP7 positivity in experimentally infected horses at 7 days post-infection, compared to 13 days for ELISA. This novel immunoassay provides a platform for developing multiplex assays, in which the presence of antibodies against multiple ASHV antigens can be detected simultaneously. This would be useful for serotyping or for differentiating infected from vaccinated animals. © 2015 Blackwell Verlag GmbH.

  6. Determination of PCBs in fish using enzyme-linked immunosorbent assay (ELISA)

    USGS Publications Warehouse

    Lasrado, J.A.; Santerre, C.R.; Zajicek, J.L.; Stahl, J.R.; Tillitt, D.E.; Deardorff, D.

    2003-01-01

    Polychlorinated biphenyls (PCBs) were determined in fish tissue using an enzyme-linked immunosorbent assay (ELISA). Standard curves for Aroclor 1248, 1254, and 1260 in catfish tissue were developed with ranges from 0.05 to 0.5 ppm and 0.5 to 5.0 ppm. Wild fish were initially analyzed using gas chromatography/electron-capture detection (GC/ECD) and those having residues within the standard curve ranges were analyzed with ELISA. Results obtained using ELISA and GC/ECD were not significantly different (p < 0.05) from 0.05 to 0.5 ppm. From 0.5 to 5.0 ppm, the standard curve for Aroclor 1254 was the best predictor of total PCB in wild fish samples.

  7. Implementation of an Enzyme Linked Immunosorbent Assay for the Quantification of Allergenic Egg Residues in Red Wines Using Commercially Available Antibodies.

    PubMed

    Koestel, Carole; Simonin, Céline; Belcher, Sandrine; Rösti, Johannes

    2016-08-01

    Since the early 2000s, labeling of potentially allergenic food components to protect people who suffer from food allergies is compulsory in numerous industrialized countries. In Europe, milk and egg components used during the winemaking process must be indicated on the label since July 1, 2012. Several ELISA procedures have been developed to detect allergenic residues in wines. However, the complexity of the wine matrix can inhibit the immunoenzymatic reaction. The aim of this study was to implement an ELISA assay for the detection of ovalbumin in red wines using commercially available antibodies. The specificity of the acquired antibodies and the absence of cross reactivity were assessed by immunoblotting and ELISA. An ELISA assay with a LOD of 14.2 μg/L and a LOQ of 56.4 μg/L of ovalbumin in aqueous solution was obtained. Differences in ELISA signals were observed when analyzing various fining agents, although reproducible conformation of the antigen could be reached for the comparison of ovalbumin and Ovicolle. The differences between samples in terms of pH could be leveled but the inhibition of the ELISA signal, positively correlated to the tannin content of the wines, could not be suppressed. Thus, standard curves of ovalbumin in several wines were obtained by relative quantification. The control steps and the difficulties encountered presented in this study should be considered by anybody working toward the development of ELISA assays for the detection of allergenic residues in complex food matrices. © 2016 The Authors. Journal of Food Science published by Wiley Periodicals, Inc. on behalf of Institute of Food Technologists.

  8. Conversion of a Capture ELISA to a Luminex xMAP Assay using a Multiplex Antibody Screening Method

    PubMed Central

    Baker, Harold N.; Murphy, Robin; Lopez, Erica; Garcia, Carlos

    2012-01-01

    The enzyme-linked immunosorbent assay (ELISA) has long been the primary tool for detection of analytes of interest in biological samples for both life science research and clinical diagnostics. However, ELISA has limitations. It is typically performed in a 96-well microplate, and the wells are coated with capture antibody, requiring a relatively large amount of sample to capture an antigen of interest . The large surface area of the wells and the hydrophobic binding of capture antibody can also lead to non-specific binding and increased background. Additionally, most ELISAs rely upon enzyme-mediated amplification of signal in order to achieve reasonable sensitivity. Such amplification is not always linear and can thus skew results. In the past 15 years, a new technology has emerged that offers the benefits of the ELISA, but also enables higher throughput, increased flexibility, reduced sample volume, and lower cost, with a similar workflow 1, 2. Luminex xMAP Technology is a microsphere (bead) array platform enabling both monoplex and multiplex assays that can be applied to both protein and nucleic acid applications 3-5. The beads have the capture antibody covalently immobilized on a smaller surface area, requiring less capture antibody and smaller sample volumes, compared to ELISA, and non-specific binding is significantly reduced. Smaller sample volumes are important when working with limiting samples such as cerebrospinal fluid, synovial fluid, etc. 6. Multiplexing the assay further reduces sample volume requirements, enabling multiple results from a single sample. Recent improvements by Luminex include: the new MAGPIX system, a smaller, less expensive, easier-to-use analyzer; Low-Concentration Magnetic MagPlex Microspheres which eliminate the need for expensive filter plates and come in a working concentration better suited for assay development and low-throughput applications; and the xMAP Antibody Coupling (AbC) Kit, which includes a protocol, reagents, and consumables necessary for coupling beads to the capture antibody of interest. (See Materials section for a detailed list of kit contents.) In this experiment, we convert a pre-optimized ELISA assay for TNF-alpha cytokine to the xMAP platform and compare the performance of the two methods 7-11. TNF-alpha is a biomarker used in the measurement of inflammatory responses in patients with autoimmune disorders. We begin by coupling four candidate capture antibodies to four different microsphere sets or regions. When mixed together, these four sets allow for the simultaneous testing of all four candidates with four separate detection antibodies to determine the best antibody pair, saving reagents, sample and time. Two xMAP assays are then constructed with the two most optimal antibody pairs and their performance is compared to that of the original ELISA assay in regards to signal strength, dynamic range, and sensitivity. PMID:22806215

  9. A Simple Method to Quantitate IP-10 in Dried Blood and Plasma Spots

    PubMed Central

    Aabye, Martine G.; Eugen-Olsen, Jesper; Werlinrud, Anne Marie; Holm, Line Lindebo; Tuuminen, Tamara; Ravn, Pernille; Ruhwald, Morten

    2012-01-01

    Background Antigen specific release of IP-10 is an established marker for infection with M.tuberculosis. Compared to IFN-γ, IP-10 is released in 100-fold higher concentrations enabling the development of novel assays for detection. Dried blood spots are a convenient sample for high throughput newborn screening. Aim To develop a robust and sensitive ELISA-based assay for IP-10 detection in plasma, dried blood spots (DBS) and dried plasma spots (DPS); to validate the ELISA in clinically relevant samples; and to assess the performance of the assay for detection of Cytomegalovirus (CMV) and M.tuberculosis specific immune responses. Method We raised mice and rat monoclonal antibodies against human IP-10 and developed an ELISA. The assay was validated and applied to the detection of CMV and M.tuberculosis specific responses in 18 patients with immune reactivity towards M.tuberculosis and 32 healthy controls of which 22 had immune reactivity towards CMV and none towards M.tuberculosis. We compared the performance of this new assay to IFN-γ. Results The ELISA was reliable for IP-10 detection in both plasma and filter paper samples. The linear range of the ELISA was 2.5–600 pg/ml. IFN-γ was not readily detectable in DPS samples. IP-10 was stabile in filter paper samples for at least 4 weeks at 37°C. The correlation between IP-10 detected in plasma, DPS and DBS samples was excellent (r2>0.97). Conclusions This newly developed assay is reliable for IP-10 quantification in plasma, DBS and DPS samples from antigen stimulated and non-stimulated whole blood. The filter paper assays enable easy sample acquisition and transport at ambient temperature e.g. via the postal system. The system can potentially simplify diagnostic assays for M.tuberculosis and CMV infection. PMID:22761744

  10. Development of Prototype Filovirus Recombinant Antigen Immunoassays

    PubMed Central

    Boisen, Matt L.; Oottamasathien, Darin; Jones, Abigail B.; Millett, Molly M.; Nelson, Diana S.; Bornholdt, Zachary A.; Fusco, Marnie L.; Abelson, Dafna M.; Oda, Shun-ichiro; Hartnett, Jessica N.; Rowland, Megan M.; Heinrich, Megan L.; Akdag, Marjan; Goba, Augustine; Momoh, Mambu; Fullah, Mohammed; Baimba, Francis; Gbakie, Michael; Safa, Sadiki; Fonnie, Richard; Kanneh, Lansana; Cross, Robert W.; Geisbert, Joan B.; Geisbert, Thomas W.; Kulakosky, Peter C.; Grant, Donald S.; Shaffer, Jeffery G.; Schieffelin, John S.; Wilson, Russell B.; Saphire, Erica Ollmann; Branco, Luis M.; Garry, Robert F.; Khan, S. Humarr; Pitts, Kelly R.

    2015-01-01

    Background. Throughout the 2014–2015 Ebola outbreak in West Africa, major gaps were exposed in the availability of validated rapid diagnostic platforms, protective vaccines, and effective therapeutic agents. These gaps potentiated the development of prototype rapid lateral flow immunodiagnostic (LFI) assays that are true point-of-contact platforms, for the detection of active Ebola infections in small blood samples. Methods. Recombinant Ebola and Marburg virus matrix VP40 and glycoprotein (GP) antigens were used to derive a panel of monoclonal and polyclonal antibodies. Antibodies were tested using a multivariate approach to identify antibody-antigen combinations suitable for enzyme-linked immunosorbent assay (ELISA) and LFI assay development. Results. Polyclonal antibodies generated in goats were superior reagents for capture and detection of recombinant VP40 in test sample matrices. These antibodies were optimized for use in antigen-capture ELISA and LFI assay platforms. Prototype immunoglobulin M (IgM)/immunoglobulin G (IgG) ELISAs were similarly developed that specifically detect Ebola virus–specific antibodies in the serum of experimentally infected nonhuman primates and in blood samples obtained from patients with Ebola from Sierra Leone. Conclusions. The prototype recombinant Ebola LFI assays developed in these studies have sensitivities that are useful for clinical diagnosis of acute ebolavirus infections. The antigen-capture and IgM/IgG ELISAs provide additional confirmatory assay platforms for detecting VP40 and other ebolavirus-specific immunoglobulins. PMID:26232440

  11. One-tube loop-mediated isothermal amplification combined with restriction endonuclease digestion and ELISA for colorimetric detection of resistance to isoniazid, ethambutol and streptomycin in Mycobacterium tuberculosis isolates.

    PubMed

    Lee, Mei-Feng; Chen, Yen-Hsu; Hsu, Hui-Jine; Peng, Chien-Fang

    2010-10-01

    In this study, we designed a simple and rapid colorimetric detection method, a one-tube loop-mediated isothermal amplification (LAMP)-PCR-hybridization-restriction endonuclease-ELISA [one-tube LAMP-PCR-HY-RE-ELISA] system, to detect resistance to isoniazid, ethambutol and streptomycin in strains of Mycobacterium tuberculosis isolated from clinical specimens. The clinical performance of this method for detecting isoniazid-resistant, ethambutol-resistant and streptomycin-resistant isolates of M. tuberculosis showed 98.9%, 94.3% and 93.8%, respectively. This assay is rapid and convenient that can be performed within one working day. One-tube LAMP-PCR-HY-RE-ELISA system was designed based on hot spot point mutations in target drug-resistant genes, using LAMP-PCR, hybridization, digestion with restriction endonuclease and colorimetric method of ELISA. In this study, LAMP assay was used to amplify DNA from drug-resistant M. tuberculosis, and ELISA was used for colorimetrical determination. This assay will be a useful tool for rapid diagnosis of mutant codons in strains of M. tuberculosis for isoniazid at katG 315 and katG 463, ethambutol at embB 306 and embB 497, and streptomycin at rpsL 43. Crown Copyright © 2010. Published by Elsevier B.V. All rights reserved.

  12. Effects of canine parvovirus strain variations on diagnostic test results and clinical management of enteritis in dogs.

    PubMed

    Markovich, Jessica E; Stucker, Karla M; Carr, Alaina H; Harbison, Carole E; Scarlett, Janet M; Parrish, Colin R

    2012-07-01

    To estimate the prevalence of canine parvovirus (CPV) strains among dogs with enteritis admitted to a referral hospital in the southwestern United States during an 11-month period and to compare diagnostic test results, disease severity, and patient outcome among CPV strains. Prospective observational study. 72 dogs with histories and clinical signs of parvoviral enteritis. For each dog, a fecal sample or rectal swab specimen was evaluated for CPV antigen via an ELISA. Subsequently, fecal samples (n = 42 dogs) and pharyngeal swab specimens (16) were obtained and tested for CPV antigen via an ELISA and CPV DNA via a PCR assay. For specimens with CPV-positive results via PCR assay, genetic sequencing was performed to identify the CPV strain. 56 dogs tested positive for CPV via ELISA or PCR assay. For 42 fecal samples tested via both ELISA and PCR assay, 27 had positive results via both assays, whereas 6 had positive PCR assay results only. Ten pharyngeal swab specimens yielded positive PCR assay results. Genetic sequencing was performed on 34 fecal or pharyngeal swab specimens that had CPV-positive PCR assay results; 25 (73.5%) were identified as containing CPV type-2c, and 9 (26.5%) were identified as containing CPV type-2b. No association was found between CPV strain and disease severity or clinical outcome. CPV type-2b and CPV type-2c posed similar health risks for dogs; therefore, genetic sequencing of CPV does not appear necessary for clinical management of infected patients. The diagnostic tests used could detect CPV type-2c.

  13. Immunological Tools: Engaging Students in the Use and Analysis of Flow Cytometry and Enzyme-linked Immunosorbent Assay (ELISA)

    ERIC Educational Resources Information Center

    Ott, Laura E.; Carson, Susan

    2014-01-01

    Flow cytometry and enzyme-linked immunosorbent assay (ELISA) are commonly used techniques associated with clinical and research applications within the immunology and medical fields. The use of these techniques is becoming increasingly valuable in many life science and engineering disciplines as well. Herein, we report the development and…

  14. AN ENZYME LINKED IMMUNOSORBENT ASSAY (ELISA) METHOD FOR THE URINARY BIOMONITORING OF 2,4-DICHLOROPHRENOCYACETIC ACID (2,4-D)

    EPA Science Inventory

    An enzyme-linked immunosorbent assay (ELISA) method was developed to quantitatively measure 2,4-dichlorophenoyacetic acid (2,4-D) in human urine. Samples were diluted (1:5) with phosphate-buffered saline, 0.05% Tween 20, with 0.02% sodium azide, and analyzed by a 96-microwekk pl...

  15. A false positive food chain error associated with a generic predator gut content ELISA

    USDA-ARS?s Scientific Manuscript database

    Conventional prey-specific gut content ELISA and PCR assays are useful for identifying predators of insect pests in nature. However, these assays are prone to yielding certain types of food chain errors. For instance, it is possible that prey remains can pass through the food chain as the result of ...

  16. A sensitive monoclonal antibody-based enzyme-linked immunosorbent assay for chlorpyrifos residue determination in Chinese agricultural smaples

    USDA-ARS?s Scientific Manuscript database

    A monoclonal antibody-based competitive antibody-coated enzyme-linked immunosorbent assay (ELISA) was developed and optimized for determining chlorpyrifos residue in agricultural products. The IC50 and IC10 of this ELISA were 3.3 ng/mL and 0.1 ng/mL respectively. The average recoveries recovery rate...

  17. Multi-Laboratory Validation of Estrone (E1) ELISA Methods

    EPA Science Inventory

    This project is a round-robin evaluation of commercially available Enzyme-Linked Immunosorbent Assay (ELISA) technology to quantitatively or qualitatively measure the hormone estrone (E1) in combined animal feeding operation (CAFO) receiving streams. ELISA is meant to be a simpl...

  18. Simultaneous detection of antibodies to five Actinobacillus pleuropneumoniae serovars using bead-based multiplex analysis.

    PubMed

    Berger, Sanne Schou; Lauritsen, Klara Tølbøll; Boas, Ulrik; Lind, Peter; Andresen, Lars Ole

    2017-11-01

    We developed and made a preliminary validation of a bead-based multiplexed immunoassay for simultaneous detection of porcine serum antibodies to Actinobacillus pleuropneumoniae serovars 1, 2, 6, 7, and 12. Magnetic fluorescent beads were coupled with A. pleuropneumoniae antigens and tested with a panel of serum samples from experimentally infected pigs and with serum samples from uninfected and naturally infected pigs. The multiplex assay was compared to in-house ELISAs and complement fixation (CF) tests, which have been used for decades as tools for herd classification in the Danish Specific Pathogen Free system. Assay specificities and sensitivities as well as the corresponding cutoff values were determined using receiver operating characteristic (ROC) curve analysis, and the A. pleuropneumoniae multiplex assay showed good correlation with the in-house ELISAs and CF tests with areas under ROC curves ≥ 0.988. Benefits of multiplexed assays compared to ELISAs and CF tests include reduced serum sample volumes needed for analysis, less labor, and shorter assay time.

  19. Evaluation of microtiter-plate enzyme-linked immunosorbent assay for the analysis of triazine and chloroacetanilide herbicides in rainfall

    USGS Publications Warehouse

    Pomes, M.L.; Thurman, E.M.; Aga, D.S.; Goolsby, D.A.

    1998-01-01

    Triazine and chloroacetanilide concentrations in rainfall samples collected from a 23-state region of the United States were analyzed with microtiter-plate enzyme-linked immunosorbent assay (ELISA). Thirty-six percent of rainfall samples (2072 out of 5691) were confirmed using gas chromatography/mass spectrometry (GC/MS) to evaluate the operating performance of ELISA as a screening test. Comparison of ELISA to GC/MS results showed that the two ELISA methods accurately reported GC/MS results (m = 1), but with more variability evident with the triazine than with the chloroacetanilide ELISA. Bayes's rule, a standardized method to report the results of screening tests, indicated that the two ELISA methods yielded comparable predictive values (80%), but the triazine ELISA yielded a false- positive rate of 11.8% and the chloroacetanilide ELISA yielded a false- negative rate of 23.1%. The false-positive rate for the triazine ELISA may arise from cross reactivity with an unknown triazine or metabolite. The false-negative rate of the chloroacetanilide ELISA probably resulted from a combination of low sensitivity at the reporting limit of 0.15 ??g/L and a distribution characterized by 75% of the samples at or below the reporting limit of 0.15 ??g/L.Triazine and chloroacetanilide concentrations in rainfall samples collected from a 23-state region of the United States were analyzed with microtiter-plate enzyme-linked immunosorbent assay (ELISA). Thirty-six percent of rainfall samples (2072 out of 5691) were confirmed using gas chromatography/mass spectrometry (GC/MS) to evaluate the operating performance of ELISA as a screening test. Comparison of ELISA to GC/MS results showed that the two ELISA methods accurately reported GC/MS results (m = 1), but with more variability evident with the triazine than with the chloroacetanilide ELISA. Bayes's rule, a standardized method to report the results of screening tests, indicated that the two ELISA methods yielded comparable predictive values (80%), but the triazine ELISA yielded a false-positive rate of 11.8% and the chloroacetanilide ELISA yielded a false-negative rate of 23.1%. The false-positive rate for the triazine ELISA may arise from cross reactivity with an unknown triazine or metabolite. The false-negative rate of the chloroacetanilide ELISA probably resulted from a combination of low sensitivity at the reporting limit of 0.15 ??g/L and a distribution characterized by 75% of the samples at or below the reporting limit of 0.15 ??g/L.

  20. Parallel human genome analysis: microarray-based expression monitoring of 1000 genes.

    PubMed Central

    Schena, M; Shalon, D; Heller, R; Chai, A; Brown, P O; Davis, R W

    1996-01-01

    Microarrays containing 1046 human cDNAs of unknown sequence were printed on glass with high-speed robotics. These 1.0-cm2 DNA "chips" were used to quantitatively monitor differential expression of the cognate human genes using a highly sensitive two-color hybridization assay. Array elements that displayed differential expression patterns under given experimental conditions were characterized by sequencing. The identification of known and novel heat shock and phorbol ester-regulated genes in human T cells demonstrates the sensitivity of the assay. Parallel gene analysis with microarrays provides a rapid and efficient method for large-scale human gene discovery. Images Fig. 1 Fig. 2 Fig. 3 PMID:8855227

  1. Direct replacement of antibodies with molecularly imprinted polymer nanoparticles in ELISA--development of a novel assay for vancomycin.

    PubMed

    Chianella, Iva; Guerreiro, Antonio; Moczko, Ewa; Caygill, J Sarah; Piletska, Elena V; De Vargas Sansalvador, Isabel M Perez; Whitcombe, Michael J; Piletsky, Sergey A

    2013-09-03

    A simple and straightforward technique for coating microplate wells with molecularly imprinted polymer nanoparticles (nanoMIPs) to develop assays similar to the enzyme-linked immunosorbent assay (ELISA) is presented here for the first time. NanoMIPs were synthesized by a solid-phase approach with an immobilized vancomycin (template) and characterized using Biacore 3000, dynamic light scattering, and electron microscopy. Immobilization, blocking, and washing conditions were optimized in microplate format. The detection of vancomycin was achieved in competitive binding experiments with a horseradish peroxidase-vancomycin conjugate. The assay was capable of measuring vancomycin in buffer and in blood plasma within the range of 0.001-70 nM with a detection limit of 0.0025 nM (2.5 pM). The sensitivity of the assay was 3 orders of magnitude better than a previously described ELISA based on antibodies. In these experiments, nanoMIPs have shown high affinity and minimal interference from blood plasma components. Immobilized nanoMIPs were stored for 1 month at room temperature without any detrimental effects to their binding properties. The high affinity of nanoMIPs and the lack of a requirement for cold chain logistics make them an attractive alternative to traditional antibodies used in ELISA.

  2. Comparison of innovative molecular approaches and standard spore assays for assessment of surface cleanliness.

    PubMed

    Cooper, Moogega; La Duc, Myron T; Probst, Alexander; Vaishampayan, Parag; Stam, Christina; Benardini, James N; Piceno, Yvette M; Andersen, Gary L; Venkateswaran, Kasthuri

    2011-08-01

    A bacterial spore assay and a molecular DNA microarray method were compared for their ability to assess relative cleanliness in the context of bacterial abundance and diversity on spacecraft surfaces. Colony counts derived from the NASA standard spore assay were extremely low for spacecraft surfaces. However, the PhyloChip generation 3 (G3) DNA microarray resolved the genetic signatures of a highly diverse suite of microorganisms in the very same sample set. Samples completely devoid of cultivable spores were shown to harbor the DNA of more than 100 distinct microbial phylotypes. Furthermore, samples with higher numbers of cultivable spores did not necessarily give rise to a greater microbial diversity upon analysis with the DNA microarray. The findings of this study clearly demonstrated that there is not a statistically significant correlation between the cultivable spore counts obtained from a sample and the degree of bacterial diversity present. Based on these results, it can be stated that validated state-of-the-art molecular techniques, such as DNA microarrays, can be utilized in parallel with classical culture-based methods to further describe the cleanliness of spacecraft surfaces.

  3. A New Highly Selective and Specific Anti-puerarin polyclonal Antibody for Determination of Puerarin Using a Mannich Reaction Hapten Conjugate

    PubMed Central

    Udomsin, Orapin; Krittanai, Supaluk; Kitisripanya, Tharita; Tanaka, Hiroyuki; Putalun, Waraporn

    2017-01-01

    Background: Puerarin (PUE) is a phytoestrogen found in Pueraria candollei and Pueraria lobata. These plants are substantial for traditional medicine in various Asian countries. PUE is a key marker that can be found only in the Pueraria species. Objective: To establish the method for determination of PUE content which is required for quality control of pharmaceutical products. Materials and Methods: PUE-cationized bovine serum albumin conjugate was created via Mannich reaction. After the rabbit immunization, the obtain anti-PUE polyclonal antibody (PAb) was used to develop an enzyme-linked immunosorbent assay (ELISA). Results: An anti-PUE PAb possess a great sensitivity and specificity. The cross-reactivity analysis shows no cross-reaction of an established antibody against other substances. In addition, we successfully developed an indirect competitive ELISA (icELISA) for the quantitative analysis of PUE. The result of method validation conforms to acceptance criteria and correlates with high-performance liquid chromatography, the reference method. The icELISA was applied to determine PUE content in Pueraria spp. plant samples and its derived pharmaceutical products. Conclusion: This highly specific immunogen was created from the Mannich reaction. An icELISA can also be applied to other research propose in the further studies. SUMMARY The new immunogen conjugated (puerarin-cBSA) via Mannich reaction was successfully in rising of antibody against puerarin (PUE)The obtained anti-PUE polyclonal antibody (PAb) was high sensitivity and specificity to PUEAn indirect competitive enzyme-linked immunosorbent assay (icELISA) was developed and validated using anti-PUE PAbThe established icELISA was applied to determine PUE content in various tuberous root of Pueraria sppMoreover, icELISA method can be applicable in Pueraria spp. derived products. Abbreviations used: PUE: Puerarin; PAb: Polyclonal antibody; ELISA: Enzyme-linked immunosorbent assay; icELISA: Indirect competitive ELISA; cBSA: Cationized bovine serum albumin. PMID:29491643

  4. [Comparison between anti-ouabain egg yolk(IgY) and rabbit antibody(IgG) in enzyme-linked immunosorbent assay].

    PubMed

    Zhang, Ming-juan; Yang, Jun; Ge, Heng; Qiang, Lei; Duan, Zong-ming; Wang, Cong-xia; Wang, Rong; Lu, Zhuo-rern

    2007-11-01

    To improve specificity and accuracy of endogenous ouabain measurement assay. Anti-ouabain polyclonal antibody egg yolk (IgY) and anti-ouabain rabbit antibody (IgG) were prepared respectively. In the presence of two kinds of antibody, then the specificity and accuracy of enzyme-linked immunosorbent assay (ELISA) were compared. The ELISA, in the presence of IgY, provided a sensitivity of the average intraassay coefficient of variation(CV) was 2.03%, and the inter-assay CV was 2.34% respectively. In contrast, IgG were 2.83% and 3.29%. No significant interferences were observed with hydrocortisone and dexamethasone. There was 3.45% vs. 5.95%, 3.20% vs. 5.20% of crossreaction with cedilanid and digoxin. The specificity and accuracy of ELISA, in which IgY was used, were more better than IgG.

  5. Evaluation of enzyme-linked immunosorbent and alternative assays for detection of HIV antibodies using panels of Brazilian sera.

    PubMed

    Ivo-Dos-Santos, J; Mello, D L; Couto-Fernandez, J C; Passos, R M; Dias-Carneiro, L A; Castilho, E A; Galvão-Castro, B

    1990-01-01

    Sera from 472 Brazilian subjects, confirmed to be either positive or negative for HIV antibodies and comprising the total clinical spectrum of HIV infection, were utilized in the evaluation of six commercially available enzyme-linked immunosorbent assays (ELISA), as well as of four alternative assays, namely indirect immunofluorescence (IIF), passive hemagglutination (PHA), dot blot and Karpas AIDS cell test. The sensitivities ranged from 100% (Abbott and Roche ELISA) to 84.2% (PHA) and the specificities ranged from 99.3% (IIF) to 80.2% (PHA). The sensitivity and specificity of the PHA and the sensitivity of the Karpas cell test were significantly lower than those of the other tests. Although the IFF and dot blot had good sensitivities and specificities, the six ELISA were more attractive than those tests when other parameters such as ease of reading and duration of assay were considered.

  6. Development of two highly sensitive immunoassays for detection of copper ions and a suite of relevant immunochemicals.

    PubMed

    Zhao, Hongwei; Nan, Tiegui; Tan, Guiyu; Gao, Wei; Cao, Zhen; Sun, Shuo; Li, Zhaohu; Li, Qing X; Wang, Baomin

    2011-09-19

    Availability of highly sensitive assays for metal ions can help monitor and manage the environmental and food contamination. In the present study, a monoclonal antibody against Copper(II)-ethylenediaminetetraacetic acid was used to develop two sensitive ELISAs for Cu(II) analysis. Cobalt(II)-EDTA-BSA was the coating antigen in a heterologous indirect competitive ELISA (hicELISA), whereas Co(II)-EDTA-BSA-horseradish peroxidase (HRP) was the enzyme tracer in a heterologous direct competitive ELISA (hdcELISA). Both ELISAs were validated for detecting the content of Cu(II) in environmental waters. The ELISA data agreed well with those from graphite furnace atomic absorption spectroscopy. The methods of developing the Cu(II) hicELISA and hdcELISA are potentially applicable for developing ELISAs for other metals. The chelator-protein complexes such as EDTA-BSA and EDTA-BSA-HRP can form a suite of metal complexes having the consistent hapten density, location and orientation on the conjugates except the difference of the metal core, which can be used as ideal reagents to investigate the relationship between assay sensitivity and antibody affinities for the haptens and the analytes. The strategy of conjugating a haptenated protein directly with HRP can reduce the loss of HRP activity during the conjugation reaction and thus can be applicable for the development of ELISAs for small molecules. Copyright © 2011. Published by Elsevier B.V.

  7. Anti-telomere antibodies in systemic lupus erythematosus (SLE): a comparison with five antinuclear antibody assays in 430 patients with SLE and other rheumatic diseases.

    PubMed

    Salonen, E M; Miettinen, A; Walle, T K; Koskenmies, S; Kere, J; Julkunen, H

    2004-10-01

    To investigate the prevalence and diagnostic significance of antibodies against telomeric DNA in systemic lupus erythematosus (SLE) and other autoimmune rheumatic diseases, and to make comparisons with five conventional anti-DNA or anti-nuclear antibody (ANA) assays. Antibodies to telomeres, which are highly repetitive sequences of DNA (TTAGGG/CCCTAA) at the end of eukaryotic chromosomes, were measured by an enzyme linked immunosorbent assay (ELISA) in 305 patients with SLE and 125 patients with other autoimmune rheumatic diseases (78 rheumatoid arthritis, 32 primary Sjögren's syndrome, eight mixed connective tissue disease, seven miscellaneous rheumatic diseases). Other assays used were two commercial ELISA assays for anti-dsDNA using calf thymus as antigen, Crithidialuciliae immunofluorescence, and radioimmunoassay (RIA) for anti-dsDNA and immunofluorescence using Hep-2 cells for ANA. The prevalence of anti-telomere in SLE was 60%, v 5% in rheumatoid arthritis and 18% in other autoimmune rheumatic diseases. Specificity of anti-telomere for SLE was 91%; positive and negative predictive values were 95% and 46%, respectively. For anti-dsDNA by two ELISA assays using calf thymus as antigen, sensitivities were 69% and 29% and specificities 66% and 96%, respectively. Other anti-dsDNA assays had low sensitivities (RIA 43%, Crithidia immunofluorescence 13%). The association of anti-telomere with a history of nephritis in patients with SLE was stronger (p = 0.005) than by any other assay (p = 0.006-0.999). The correlations between the different assays were good (p<0.001 for all comparisons). The new ELISA for anti-telomere antibodies using standardised human dsDNA as antigen is a sensitive and highly specific test for SLE.

  8. Development of an indirect ELISA with epitope on nonstructural protein of Muscovy duck parvovirus for differentiating between infected and vaccinated Muscovy ducks.

    PubMed

    Yan, B; Ma, J-Z; Yu, T-F; Shao, S-L; Li, M; Fan, X-D

    2014-12-01

    The aim of this study was to develop an indirect enzyme-linked immunosorbent assay (i-ELISA) based on epitope AA503-509 (RANEPKE), which is on nonstructural protein of Muscovy duck parvovirus (MDPV). Sera (100) from negative and vaccinated Muscovy ducks were compared with infected sera (240) to establish the cut-off value of this i-ELISA. There was a significant difference between the positive and negative populations (P < 0·05). The adoption of this positive-negative threshold value for this i-ELISA assay resulted in specificity of 98·0%. This i-ELISA could be used as a diagnostic tool for differentiating infected Muscovy ducks from Muscovy ducks vaccinated with inactivated virus. In this study, we developed an i-ELISA based on epitope AA503-509 (RANEPKE), which is on nonstructural protein of MDPV. This i-ELISA could be used as a diagnostic tool for differentiating infected Muscovy ducks from Muscovy ducks vaccinated with inactivated virus. © 2014 The Society for Applied Microbiology.

  9. Antigen-capture blocking enzyme-linked immunosorbent assay based on a baculovirus recombinant antigen to differentiate Transmissible gastroenteritis virus from Porcine respiratory coronavirus antibodies.

    PubMed

    López, Lissett; Venteo, Angel; García, Marga; Camuñas, Ana; Ranz, Ana; García, Julia; Sarraseca, Javier; Anaya, Carmen; Rueda, Paloma

    2009-09-01

    A new commercially available antigen-capture, blocking enzyme-linked immunosorbent assay (antigen-capture b-ELISA), based on baculovirus truncated-S recombinant protein of Transmissible gastroenteritis virus (TGEV) and 3 specific monoclonal antibodies, was developed and evaluated by examining a panel of 453 positive Porcine respiratory coronavirus (PRCoV), 31 positive TGEV, and 126 negative field sera by using another commercially available differential coronavirus b-ELISA as the reference technique to differentiate TGEV- from PRCoV-induced antibodies. The recombinant S protein-based ELISA appeared to be 100% sensitive for TGEV and PRCoV detection and highly specific for TGEV and PRCoV detection (100% and 92.06%, respectively), when qualitative results (positive or negative) were compared with those of the reference technique. In variability experiments, the ELISA gave consistent results when the same serum was evaluated on different wells and different plates. These results indicated that truncated recombinant S protein is a suitable alternative to the complete virus as antigen in ELISA assays. The use of recombinant S protein as antigen offers great advantages because it is an easy-to-produce, easy-to-standardize, noninfectious antigen that does not require further purification or concentration. Those advantages represent an important improvement for antigen preparation, in comparison with other assays in which an inactivated virus from mammalian cell cultures is used.

  10. ELISA: Methods and Protocols

    USDA-ARS?s Scientific Manuscript database

    The antibody is central to the performance of an ELISA providing the basis of analyte selection and detection. It is the interaction of antibody with analyte under defined conditions that dictates the outcome of the ELISA and deviations in those conditions will impact assay performance. The aim of...

  11. Improvement of an enzyme-linked immunosorbent assay for equine herpesvirus type 4 by using a synthetic-peptide 24-mer repeat sequence of glycoprotein G as an antigen

    PubMed Central

    BANNAI, Hiroshi; NEMOTO, Manabu; TSUJIMURA, Koji; YAMANAKA, Takashi; MAEDA, Ken; KONDO, Takashi

    2015-01-01

    To increase the sensitivity of an enzyme-linked immunosorbent assay (ELISA) for equine herpesvirus type 4 (EHV-4) that uses a 12-mer peptide of glycoprotein G (gG4-12-mer: MKNNPIYSEGSL) [4], we used a longer peptide consisting of a 24-mer repeat sequence (gG4-24-mer: MKNNPIYSEGSLMLNVQHDDSIHT) as an antigen. Sera of horses experimentally infected with EHV-4 reacted much more strongly to the gG4-24-mer peptide than to the gG4-12-mer peptide. We used peptide ELISAs to test paired sera from horses naturally infected with EHV-4 (n=40). gG4-24-mer ELISA detected 37 positive samples (92.5%), whereas gG4-12-mer ELISA detected only 28 (70.0%). gG4-24-mer ELISA was much more sensitive than gG4-12-mer ELISA. PMID:26424485

  12. Improvement of an enzyme-linked immunosorbent assay for equine herpesvirus type 4 by using a synthetic-peptide 24-mer repeat sequence of glycoprotein G as an antigen.

    PubMed

    Bannai, Hiroshi; Nemoto, Manabu; Tsujimura, Koji; Yamanaka, Takashi; Maeda, Ken; Kondo, Takashi

    2016-02-01

    To increase the sensitivity of an enzyme-linked immunosorbent assay (ELISA) for equine herpesvirus type 4 (EHV-4) that uses a 12-mer peptide of glycoprotein G (gG4-12-mer: MKNNPIYSEGSL) [4], we used a longer peptide consisting of a 24-mer repeat sequence (gG4-24-mer: MKNNPIYSEGSLMLNVQHDDSIHT) as an antigen. Sera of horses experimentally infected with EHV-4 reacted much more strongly to the gG4-24-mer peptide than to the gG4-12-mer peptide. We used peptide ELISAs to test paired sera from horses naturally infected with EHV-4 (n=40). gG4-24-mer ELISA detected 37 positive samples (92.5%), whereas gG4-12-mer ELISA detected only 28 (70.0%). gG4-24-mer ELISA was much more sensitive than gG4-12-mer ELISA.

  13. A comparison of two antigen-detection ELISA for detecting infection of Dirofilaria immitis in dogs.

    PubMed

    Euclid, J M; Copeman, D B

    1997-09-01

    A survey on 87 dogs necropsied in the Townsville region revealed 34 (39%) were infected with Dirofilaria immitis. Infected dogs had an average of 6.1 adult worms in the heart and associated blood vessels. The VetRED assay detected 23 of the 34 infected dogs (sensitivity 65%) and the Og4C3 ELISA detected 27 (sensitivity 80%). Sensitivity of the VetRED and Og4C3 ELISA increased to 88 and 94% respectively in dogs with three or more worms. Both tests detected correctly all uninfected dogs. Despite the higher accuracy of the Og4C3 ELISA, compared to the VetRED assay, it is unlikely to be used widely as a field test for heartworm unless it can be modified from its present plate ELISA format which takes 4 hours, into one which is more rapid and convenient. However, as a reference ELISA, it may well be worthwhile in situations which require considerable accuracy for detecting D. immitis infection.

  14. Enzyme-linked immunosorbent assay using a recombinant baculovirus-expressed Bacillus anthracis protective antigen (PA): measurement of human anti-PA antibodies.

    PubMed Central

    Iacono-Connors, L C; Novak, J; Rossi, C; Mangiafico, J; Ksiazek, T

    1994-01-01

    We developed an antigen capture enzyme-linked immunosorbent assay (ELISA) which does not require purified protective antigen (PA) for detection of human antibodies to Bacillus anthracis PA. Lysates of Spodoptera frugiperda (Sf-9) cells infected with recombinant baculovirus containing the PA gene were used as the source of PA to develop the ELISA. Recombinant PA from crude Sf-9 cell lysates or PA purified from B. anthracis Sterne strain was captured by an anti-PA monoclonal antibody coated onto microtiter plates. We demonstrated that human serum antibody titers to PA were identical in the ELISA whether we used crude Sf-9 cell lysates containing recombinant baculovirus-expressed PA or purified Sterne PA. Finally, false-positive results observed in a direct ELISA were eliminated with this antigen capture ELISA. Thus, the antigen capture ELISA with crude preparations of baculovirus-expressed PA is reliable, safe, and inexpensive for determining anti-PA antibody levels in human sera. PMID:7496927

  15. Enzyme-linked immunosorbent assay detection and bioactivity of Cry1Ab protein fragments.

    PubMed

    Albright, Vurtice C; Hellmich, Richard L; Coats, Joel R

    2016-12-01

    The continuing use of transgenic crops has led to an increased interest in the fate of insecticidal crystalline (Cry) proteins in the environment. Enzyme-linked immunosorbent assays (ELISAs) have emerged as the preferred detection method for Cry proteins in environmental matrices. Concerns exist that ELISAs are capable of detecting fragments of Cry proteins, which may lead to an overestimation of the concentration of these proteins in the environment. Five model systems were used to generate fragments of the Cry1Ab protein, which were then analyzed by ELISAs and bioassays. Fragments from 4 of the model systems were not detectable by ELISA and did not retain bioactivity. Fragments from the proteinase K model system were detectable by ELISA and retained bioactivity. In most cases, ELISAs appear to provide an accurate estimation of the amount of Cry proteins in the environment, as detectable fragments retained bioactivity and nondetectable fragments did not retain bioactivity. Environ Toxicol Chem 2016;35:3101-3112. © 2016 SETAC. © 2016 SETAC.

  16. Commercial Milk Enzyme-Linked Immunosorbent Assay (ELISA) Kit Reactivities to Purified Milk Proteins and Milk-Derived Ingredients.

    PubMed

    Ivens, Katherine O; Baumert, Joseph L; Taylor, Steve L

    2016-07-01

    Numerous commercial enzyme-linked immunosorbent assay (ELISA) kits exist to quantitatively detect bovine milk residues in foods. Milk contains many proteins that can serve as ELISA targets including caseins (α-, β-, or κ-casein) and whey proteins (α-lactalbumin or β-lactoglobulin). Nine commercially-available milk ELISA kits were selected to compare the specificity and sensitivity with 5 purified milk proteins and 3 milk-derived ingredients. All of the milk kits were capable of quantifying nonfat dry milk (NFDM), but did not necessarily detect all individual protein fractions. While milk-derived ingredients were detected by the kits, their quantitation may be inaccurate due to the use of different calibrators, reference materials, and antibodies in kit development. The establishment of a standard reference material for the calibration of milk ELISA kits is increasingly important. The appropriate selection and understanding of milk ELISA kits for food analysis is critical to accurate quantification of milk residues and informed risk management decisions. © 2016 Institute of Food Technologists®

  17. Production and Characterization of Monoclonal Antibody against Recombinant Virus Coat Protein CP42.

    PubMed

    Shibaei, Naeimeh; Majidi, Jafar; Razavi, Khadijeh; Karkhane, Ali Asghar; Sokhandan-Bashir, Nemat; Aghebati-Maleki, Leili

    2017-02-01

    There are many studies related to the production of a ELISA kit for diagnosing virus infections. However, production of most kits depends on purification of whole virus particles, which involves the use of costly equipment and reagents. The purpose of this study was to check out if the anti-CP42 antibodies could be used as a diagnostic assay for detection of Grapevine fanleaf Virus (GFLV). In this study, recombinant GFLV coat protein gene related to selected antigenic determinants was inserted into pET-28a bacterial expression vector and the construct (pET-28a CP42) was cloned into E. coli strain (DE3). Expressed protein was verified with western blotting assay by the use of commercially available anti-GFLV antibody. The recombinant protein was purified using nickel-nitrilotriacetic acid (Ni-NTA) resin. Balb/c mice were immunized with purified protein and splenocytes of hyperimmunized mice were fused with murine myeloma Sp2/0 cells. Positive hybridomas were selected by ELISA using CP42 as coating antigen. The results showed that monoclonal antibody (MAb) specific to CP42 has been successfully generated. Efficiency of produced antibody was analyzed by ELISA and western blotting assay using some confirmed grapevine samples. The infection was confirmed previously based on morphological features and ELISA assay, performed using commercial anti-GFLV antibody. The monoclonal antibody reacted with antigen in ELISA and immunoblot method. Our results demonstrated that anti recombinant CP42 monoclonal antibodies are able to diagnose whole virus in infected grapevine sample using ELISA test.

  18. Accurate Determination of Soluble Axl by Enzyme-Linked Immunosorbent Assay.

    PubMed

    Dengler, Mirko; Huber, Heidemarie; Müller, Christian J; Zellmer, Angela; Rauch, Peter; Mikulits, Wolfgang

    2016-11-01

    Levels of soluble Axl (sAxl) are routinely assessed in human sera by sandwich enzyme-linked immunosorbent assay (ELISA). Although sAxl values are suggested to diagnose different types of disorders, no uniform ELISA method is available, allowing the reliable interassay comparison between results. Furthermore, little is known about the stability of sAxl under storage conditions, which is a relevant parameter for biomedical trials. The evaluation of sAxl stability under various stress conditions and the determination of proper conditions to use the sAxl ELISA for routine clinical applications are of great interest. In this study, serum samples were subjected to freeze-thaw cycles and incubation at different temperatures to analyze the stability of sAxl by ELISA. Dilution and spike-in experiments were carried out to examine the impact of serum and diluent components on the ELISA performance. Various diluents and media were employed to resolve masking effects of the serum. The assay components were further optimized for long-term usability by treatment with stabilizers and validation under temperature stress. Indeed, sAxl showed long-term stability in serum during freeze-thaw cycles and incubation under temperature stress conditions. The dilution experiments revealed that unknown components in the serum caused masking effects that can be reduced by proper dilutions. The assay performance was further increased by using a standardized buffer system to dilute serum samples. Stabilization of coated plates and of streptavidin-horseradish peroxidase allowed long-term storage for up to 6 months. In sum, our data demonstrate proper ELISA conditions, allowing the accurate analysis of sAxl levels in human serum.

  19. Development and potential applications of microarrays based on fluorescent nanocrystal-encoded beads for multiplexed cancer diagnostics

    NASA Astrophysics Data System (ADS)

    Brazhnik, Kristina; Grinevich, Regina; Efimov, Anton E.; Nabiev, Igor; Sukhanova, Alyona

    2014-05-01

    Advanced multiplexed assays have recently become an indispensable tool for clinical diagnostics. These techniques provide simultaneous quantitative determination of multiple biomolecules in a single sample quickly and accurately. The development of multiplex suspension arrays is currently of particular interest for clinical applications. Optical encoding of microparticles is the most available and easy-to-use technique. This technology uses fluorophores incorporated into microbeads to obtain individual optical codes. Fluorophore-encoded beads can be rapidly analyzed using classical flow cytometry or microfluidic techniques. We have developed a new generation of highly sensitive and specific diagnostic systems for detection of cancer antigens in human serum samples based on microbeads encoded with fluorescent quantum dots (QDs). The designed suspension microarray system was validated for quantitative detection of (1) free and total prostate specific antigen (PSA) in the serum of patients with prostate cancer and (2) carcinoembryonic antigen (CEA) and cancer antigen 15-3 (CA 15-3) in the serum of patients with breast cancer. The serum samples from healthy donors were used as a control. The antigen detection is based on the formation of an immune complex of a specific capture antibody (Ab), a target antigen (Ag), and a detector Ab on the surface of the encoded particles. The capture Ab is bound to the polymer shell of microbeads via an adapter molecule, for example, protein A. Protein A binds a monoclonal Ab in a highly oriented manner due to specific interaction with the Fc-region of the Ab molecule. Each antigen can be recognized and detected due to a specific microbead population carrying the unique fluorescent code. 100 and 231 serum samples from patients with different stages of prostate cancer and breast cancer, respectively, and those from healthy donors were examined using the designed suspension system. The data were validated by comparing with the results of the "gold standard" enzyme-linked immunosorbent assay (ELISA). They have shown that our approach is a good alternative to the diagnostics of cancer markers using conventional assays, especially in early diagnostic applications.

  20. Homologous ELISA for detection of oligomeric human TNF: properties of the assay.

    PubMed

    Petyovka, N; Lyach, L; Voitenok, N N

    1995-10-26

    In order to quantify oligomeric human tumor necrosis factor-alpha (TNF), we have developed a sensitive homologous enzyme-linked immunosorbent assay (Hm-ELISA) using the same monoclonal antibody (MoAb) for both solid and liquid phase. Different anti-TNF MoAb have been compared in terms of their efficacy in the Hm-ELISA, affinity, neutralization capacity and epitope specificity. The data suggest, that effectiveness in the Hm-ELISA may represent a novel characteristic of MoAb. Of the MoAbs tested, 5 N was capable of recognizing oligomeric TNF in the Hm-ELISA with a detection limit of 15 pg/ml. Furthermore, using Hm-ELISA against human TNF, interleukin-8 (IL-8) and lymphotoxin, we have demonstrated that these cytokines are oligomeric in physiological solutions, but are converted into monomeric forms in the presence of the non-ionic detergent Tween 20. High salt buffer was employed to abrogate a nonspecific false positive reaction in the Hm-ELISA found in nearly half of the plasma samples obtained from healthy subjects. Finally, a good correlation between the Hm-ELISA and the L929 bioassay was observed for natural and recombinant TNF measured in human plasma.

  1. Mobile phone based ELISA (MELISA).

    PubMed

    Zhdanov, Arsenii; Keefe, Jordan; Franco-Waite, Luis; Konnaiyan, Karthik Raj; Pyayt, Anna

    2018-04-30

    Enzyme-linked immunosorbent assay (ELISA) is one of the most important technologies for biochemical analysis critical for diagnosis and monitoring of many diseases. Traditional systems for ELISA incubation and reading are expensive and bulky, thus cannot be used at point-of-care or in the field. Here, we propose and demonstrate a new miniature mobile phone based system for ELISA (MELISA). This system can be used to complete all steps of the assay, including incubation and reading. It weighs just 1 pound, can be fabricated at low cost, portable, and can transfer test results via mobile phone. We successfully demonstrated how MELISA can be calibrated for accurate measurements of progesterone and demonstrated successful measurements with the calibrated system. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Enzyme-linked immunosorbent assays for detection of equine antibodies specific to Sarcocystis neurona surface antigens.

    PubMed

    Hoane, Jessica S; Morrow, Jennifer K; Saville, William J; Dubey, J P; Granstrom, David E; Howe, Daniel K

    2005-09-01

    Sarcocystis neurona is the primary causative agent of equine protozoal myeloencephalitis (EPM), a common neurologic disease of horses in the Americas. We have developed a set of enzyme-linked immunosorbent assays (ELISAs) based on the four major surface antigens of S. neurona (SnSAGs) to analyze the equine antibody response to S. neurona. The SnSAG ELISAs were optimized and standardized with a sample set of 36 equine sera that had been characterized by Western blotting against total S. neurona parasite antigen, the current gold standard for S. neurona serology. The recombinant SnSAG2 (rSnSAG2) ELISA showed the highest sensitivity and specificity at 95.5% and 92.9%, respectively. In contrast, only 68.2% sensitivity and 71.4% specificity were achieved with the rSnSAG1 ELISA, indicating that this antigen may not be a reliable serological marker for analyzing antibodies against S. neurona in horses. Importantly, the ELISA antigens did not show cross-reactivity with antisera to Sarcocystis fayeri or Neospora hughesi, two other equine parasites. The accuracy and reliability exhibited by the SnSAG ELISAs suggest that these assays will be valuable tools for examining the equine immune response against S. neurona infection, which may help in understanding the pathobiology of this accidental parasite-host interaction. Moreover, with modification and further investigation, the SnSAG ELISAs have potential for use as immunodiagnostic tests to aid in the identification of horses affected by EPM.

  3. Enzyme-Linked Immunosorbent Assays for Detection of Equine Antibodies Specific to Sarcocystis neurona Surface Antigens†

    PubMed Central

    Hoane, Jessica S.; Morrow, Jennifer K.; Saville, William J.; Dubey, J. P.; Granstrom, David E.; Howe, Daniel K.

    2005-01-01

    Sarcocystis neurona is the primary causative agent of equine protozoal myeloencephalitis (EPM), a common neurologic disease of horses in the Americas. We have developed a set of enzyme-linked immunosorbent assays (ELISAs) based on the four major surface antigens of S. neurona (SnSAGs) to analyze the equine antibody response to S. neurona. The SnSAG ELISAs were optimized and standardized with a sample set of 36 equine sera that had been characterized by Western blotting against total S. neurona parasite antigen, the current gold standard for S. neurona serology. The recombinant SnSAG2 (rSnSAG2) ELISA showed the highest sensitivity and specificity at 95.5% and 92.9%, respectively. In contrast, only 68.2% sensitivity and 71.4% specificity were achieved with the rSnSAG1 ELISA, indicating that this antigen may not be a reliable serological marker for analyzing antibodies against S. neurona in horses. Importantly, the ELISA antigens did not show cross-reactivity with antisera to Sarcocystis fayeri or Neospora hughesi, two other equine parasites. The accuracy and reliability exhibited by the SnSAG ELISAs suggest that these assays will be valuable tools for examining the equine immune response against S. neurona infection, which may help in understanding the pathobiology of this accidental parasite-host interaction. Moreover, with modification and further investigation, the SnSAG ELISAs have potential for use as immunodiagnostic tests to aid in the identification of horses affected by EPM. PMID:16148170

  4. Direct Competitive Enzyme-Linked Immunosorbent Assay (ELISA).

    PubMed

    Kohl, Thomas O; Ascoli, Carl A

    2017-07-05

    The competitive enzyme-linked immunosorbent assay (ELISA) (cELISA; also called an inhibition ELISA) is designed so that purified antigen competes with antigen in the test sample for binding to an antibody that has been immobilized in microtiter plate wells. The same concept works if the immobilized molecule is antigen and the competing molecules are purified labeled antibody versus antibody in a test sample. Direct cELISAs incorporate labeled antigen or antibody, whereas indirect assay configurations use reporter-labeled secondary antibodies. The cELISA is very useful for determining the concentration of small-molecule antigens in complex sample mixtures. In the direct cELISA, antigen-specific capture antibody is adsorbed onto the microtiter plate before incubation with either known standards or unknown test samples. Enzyme-linked antigen (i.e., labeled antigen) is also added, which can bind to the capture antibody only when the antibody's binding site is not occupied by either the antigen standard or antigen in the test samples. Unbound labeled and unlabeled antigens are washed away and substrate is added. The amount of antigen in the standard or the test sample determines the amount of reporter-labeled antigen bound to antibody, yielding a signal that is inversely proportional to antigen concentration within the sample. Thus, the higher the antigen concentration in the test sample, the less labeled antigen is bound to the capture antibody, and hence the weaker is the resultant signal. © 2017 Cold Spring Harbor Laboratory Press.

  5. Low-cost and easy-to-use "on-chip ELISA" for developing health-promoting foods.

    PubMed

    Hoshino, Fumihiko; Watanabe, Osamu; Wu, Xiaohong; Takimoto, Yosuke; Osawa, Toshihiko

    2014-01-01

    We have determined that a biological molecule can be physically immobilized on a polymer containing an azobenzene (azopolymer) using irradiating light. We immobilized antibodies and antigens on the surface of an azopolymer coated glass slide (antibody array) to establish "on-chip ELISAs". The assays used the flat-surface of a glass slide and could be applied to both sandwich and competitive ELISAs. The sensitivity and accuracy of the on-chip ELISA were similar to a conventional ELISA using a polystyrene plate. Using the assay system, we proved that representative oxidative-biomarkers could be simultaneously measured from uL of urine. That should realize low-cost study on animal or human, and accelerate development of health-promoting foods. So, this new concept antibody array has promising applications in proteomic studies, and could be used to examine biomarkers to investigate health-promoting food.

  6. Application of 3D Printing Technology in Increasing the Diagnostic Performance of Enzyme-Linked Immunosorbent Assay (ELISA) for Infectious Diseases

    PubMed Central

    Singh, Harpal; Shimojima, Masayuki; Shiratori, Tomomi; An, Le Van; Sugamata, Masami; Yang, Ming

    2015-01-01

    Enzyme-linked Immunosorbent Assay (ELISA)-based diagnosis is the mainstay for measuring antibody response in infectious diseases and to support pathogen identification of potential use in infectious disease outbreaks and clinical care of individual patients. The development of laboratory diagnostics using readily available 3D printing technologies provides a timely opportunity for further expansion of this technology into immunodetection systems. Utilizing available 3D printing platforms, a ‘3D well’ was designed and developed to have an increased surface area compared to those of 96-well plates. The ease and rapidity of the development of the 3D well prototype provided an opportunity for its rapid validation through the diagnostic performance of ELISA in infectious disease without modifying current laboratory practices for ELISA. The improved sensitivity of the 3D well of up to 2.25-fold higher compared to the 96-well ELISA provides a potential for the expansion of this technology towards miniaturization and Lab-On-a-Chip platforms to reduce time, volume of reagents and samples needed for such assays in the laboratory diagnosis of infectious and other diseases including applications in other disciplines. PMID:26184194

  7. Application of 3D Printing Technology in Increasing the Diagnostic Performance of Enzyme-Linked Immunosorbent Assay (ELISA) for Infectious Diseases.

    PubMed

    Singh, Harpal; Shimojima, Masayuki; Shiratori, Tomomi; An, Le Van; Sugamata, Masami; Yang, Ming

    2015-07-08

    Enzyme-linked Immunosorbent Assay (ELISA)-based diagnosis is the mainstay for measuring antibody response in infectious diseases and to support pathogen identification of potential use in infectious disease outbreaks and clinical care of individual patients. The development of laboratory diagnostics using readily available 3D printing technologies provides a timely opportunity for further expansion of this technology into immunodetection systems. Utilizing available 3D printing platforms, a '3D well' was designed and developed to have an increased surface area compared to those of 96-well plates. The ease and rapidity of the development of the 3D well prototype provided an opportunity for its rapid validation through the diagnostic performance of ELISA in infectious disease without modifying current laboratory practices for ELISA. The improved sensitivity of the 3D well of up to 2.25-fold higher compared to the 96-well ELISA provides a potential for the expansion of this technology towards miniaturization and Lab-On-a-Chip platforms to reduce time, volume of reagents and samples needed for such assays in the laboratory diagnosis of infectious and other diseases including applications in other disciplines.

  8. A sensitive epitope-blocking ELISA for the detection of Chikungunya virus-specific antibodies in patients.

    PubMed

    Goh, Lucas Y H; Kam, Yiu-Wing; Metz, Stefan W; Hobson-Peters, Jody; Prow, Natalie A; McCarthy, Suzi; Smith, David W; Pijlman, Gorben P; Ng, Lisa F P; Hall, Roy A

    2015-09-15

    Chikungunya fever (CHIKF) has re-emerged as an arboviral disease that mimics clinical symptoms of other diseases such as dengue, malaria, as well as other alphavirus-related illnesses leading to problems with definitive diagnosis of the infection. Herein we describe the development and evaluation of a sensitive epitope-blocking ELISA (EB-ELISA) capable of specifically detecting anti-chikungunya virus (CHIKV) antibodies in clinical samples. The assay uses a monoclonal antibody (mAb) that binds an epitope on the E2 protein of CHIKV and does not exhibit cross-reactivity to other related alphaviruses. We also demonstrated the use of recombinant CHIK virus-like particles (VLPs) as a safe alternative antigen to infectious virions in the assay. Based on testing of 60 serum samples from patients in the acute or convalescent phase of CHIKV infection, the EB-ELISA provided us with 100% sensitivity, and exhibited 98.5% specificity when Ross River virus (RRV)- or Barmah Forest virus (BFV)-immune serum samples were included. This assay meets the public health demands of a rapid, robust, sensitive and specific, yet simple assay for specifically diagnosing CHIK-infections in humans. Copyright © 2015. Published by Elsevier B.V.

  9. Influence of the incubation temperature and the batch components on the sensitivity of an enzyme-linked immunosorbent assay to detect Aujeszky's disease virus glycoprotein E (gE).

    PubMed

    Cay, A B; Van der Stede, Y

    2010-12-01

    Although licensed batches of an enzyme-linked immunosorbent assay (ELISA) for Aujeszky's disease virus (ADV) were used, and the assays were performed within an ISO/IEC 17025 accredited quality control system, certain routine runs of the ADV ELISA were not validated using the quality system criteria, even when all technical parameters were controlled. Incubation at different temperatures and batch composition were identified as parameters that could result in non-validated assays/runs. Therefore, the effect of incubation temperature and batch composition on the analytical sensitivity of the ELISA was investigated. The World Organisation for Animal Health (OIE) standard reference serum ADV1 was diluted 1:8 and tested in 94 different glycoprotein E ELISA runs performed with different batches and different incubation temperatures. The incubation temperature and batch components had a significant influence on the qualitative result for the OIE standard reference serum. An incubation temperature of at least 22 degrees C was recommended, based on the results of this analysis. Which of the batch components caused these differences in sensitivity was not investigated further.

  10. An Evaluation Study of Enzyme-Linked Immunosorbent Assay (ELISA) Using Recombinant Protein Pap31 for Detection of Antibody against Bartonella bacilliformis Infection among the Peruvian Population

    PubMed Central

    Angkasekwinai, Nasikarn; Atkins, Erin H.; Romero, Sofia; Grieco, John; Chao, Chien Chung; Ching, Wei Mei

    2014-01-01

    Reliable laboratory testing is of great importance to detect Bartonella bacilliformis infection. We evaluated the sensitivity and specificity of the enzyme-linked immunosorbent assay (ELISA) using recombinant protein Pap31 (rPap31) for the detection of antibodies against B. bacilliformis as compared with immunofluorescent assay (IFA). Of the 302 sera collected between 1997 and 2000 among an at-risk Peruvian population, 103 and 34 samples tested positive for IFA-immunoglobulin G (IgG) and IFA-IgM, respectively. By using Youden's index, the cutoff values of ELISA-IgG at 0.915 gave a sensitivity of 84.5% and specificity of 94%. The cutoff values of ELISA-IgM at 0.634 gave a sensitivity of 88.2% and specificity of 85.1%. Using latent class analysis, estimates of sensitivity and specificity of almost all the assays were slightly higher than those of a conventional method of calculation. The test is proved beneficial for discriminating between infected and non-infected individuals with the advantage of low-cost and high-throughput capability. PMID:24515944

  11. Direct replacement of antibodies with molecularly imprinted polymer (MIP) nanoparticles in ELISA – development of a novel assay for vancomycin

    PubMed Central

    Chianella, Iva; Guerreiro, Antonio; Moczko, Ewa; Caygill, J. Sarah; Piletska, Elena V.; Perez De Vargas Sansalvador, Isabel M.; Whitcombe, Michael J.; Piletsky, Sergey A.

    2016-01-01

    A simple and straightforward technique for coating microplate wells with molecularly imprinted polymer nanoparticles (nanoMIPs) to develop ELISA type assays is presented here for the first time. NanoMIPs were synthesized by a solid phase approach with immobilized vancomycin (template) and characterized using Biacore 3000, dynamic light scattering and electron microscopy. Immobilization, blocking and washing conditions were optimized in microplate format. The detection of vancomycin was achieved in competitive binding experiments with a HRP-vancomycin conjugate. The assay was capable of measuring vancomycin in buffer and in blood plasma within the range 0.001-70 nM with a detection limit of 0.0025 nM (2.5 pM). The sensitivity of the assay was three orders of magnitude better than a previously described ELISA based on antibodies. In these experiments nanoMIPs have shown high affinity and minimal interference from blood plasma components. Immobilized nanoMIPs were stored for 1 month at room temperature without any detrimental effects to their binding properties. The high affinity of nanoMIPs and the lack of a requirement for cold chain logistics make them an attractive alternative to traditional antibodies used in ELISA. PMID:23947402

  12. 9 CFR 52.1 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... Test; Fluorescent Antibody Tissue Section Test; Enzyme-Linked Immunosorbent Assay (ELISA) Test, except for approved differential pseudorabies tests other than the glycoprotein I (gpI) ELISA test; Latex...

  13. 9 CFR 52.1 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... Test; Fluorescent Antibody Tissue Section Test; Enzyme-Linked Immunosorbent Assay (ELISA) Test, except for approved differential pseudorabies tests other than the glycoprotein I (gpI) ELISA test; Latex...

  14. 9 CFR 52.1 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... Test; Fluorescent Antibody Tissue Section Test; Enzyme-Linked Immunosorbent Assay (ELISA) Test, except for approved differential pseudorabies tests other than the glycoprotein I (gpI) ELISA test; Latex...

  15. 9 CFR 52.1 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Test; Fluorescent Antibody Tissue Section Test; Enzyme-Linked Immunosorbent Assay (ELISA) Test, except for approved differential pseudorabies tests other than the glycoprotein I (gpI) ELISA test; Latex...

  16. 9 CFR 52.1 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... Test; Fluorescent Antibody Tissue Section Test; Enzyme-Linked Immunosorbent Assay (ELISA) Test, except for approved differential pseudorabies tests other than the glycoprotein I (gpI) ELISA test; Latex...

  17. Undergraduate Laboratory Module for Implementing ELISA on the High Performance Microfluidic Platform

    ERIC Educational Resources Information Center

    Giri, Basant; Peesara, Ravichander R.; Yanagisawa, Naoki; Dutta, Debashis

    2015-01-01

    Implementing enzyme-linked immunosorbent assays (ELISA) in microchannels offers several advantages over its traditional microtiter plate-based format, including a reduced sample volume requirement, shorter incubation period, and greater sensitivity. Moreover, microfluidic ELISA platforms are inexpensive to fabricate and allow integration of…

  18. A Simple ELISA Exercise for Undergraduate Biology.

    ERIC Educational Resources Information Center

    Baker, William P.; Moore, Cathy R.

    Understanding of immunological techniques such as the Enzyme Linked Immuno Sorbent Assay (ELISA) is an important part of instructional units in human health, developmental biology, microbiology, and biotechnology. This paper describes a simple ELISA exercise for undergraduate biology that effectively simulates the technique using a paper model.…

  19. Immunoproteomic analysis of antibody in lymphocyte supernatant in patients with typhoid fever in Bangladesh.

    PubMed

    Charles, Richelle C; Liang, Li; Khanam, Farhana; Sayeed, M Abu; Hung, Chris; Leung, Daniel T; Baker, Stephen; Ludwig, Albrecht; Harris, Jason B; Larocque, Regina C; Calderwood, Stephen B; Qadri, Firdausi; Felgner, Philip L; Ryan, Edward T

    2014-03-01

    We have previously shown that an assay based on detection of anti-Salmonella enterica serotype Typhi antibodies in supernatant of lymphocytes harvested from patients presenting with typhoid fever (antibody in lymphocyte supernatant [ALS] assay) can identify 100% of patients with blood culture-confirmed typhoid fever in Bangladesh. In order to define immunodominant proteins within the S. Typhi membrane preparation used as antigen in these prior studies and to identify potential biomarkers unique to S. Typhi bacteremic patients, we probed microarrays containing 2,724 S. Typhi proteins with ALS collected at the time of clinical presentation from 10 Bangladeshis with acute typhoid fever. We identified 62 immunoreactive antigens when evaluating both the IgG and IgA responses. Immune responses to 10 of these antigens discriminated between individuals with acute typhoid infection and healthy control individuals from areas where typhoid infection is endemic, as well as Bangladeshi patients presenting with fever who were subsequently confirmed to have a nontyphoid illness. Using an ALS enzyme-linked immunosorbent assay (ELISA) format and purified antigen, we then confirmed that immune responses against the antigen with the highest immunoreactivity (hemolysin E [HlyE]) correctly identified individuals with acute typhoid or paratyphoid fever in Dhaka, Bangladesh. These observations suggest that purified antigens could be used with ALS and corresponding acute-phase activated B lymphocytes in diagnostic platforms to identify acutely infected patients, even in areas where enteric fever is endemic.

  20. Microarray Detection of Duplex and Triplex DNA Binders with DNA-Modified Gold Nanoparticles

    PubMed Central

    Lytton-Jean, Abigail K. R.; Han, Min Su; Mirkin, Chad A.

    2008-01-01

    We have designed a chip-based assay, using microarray technology, for determining the relative binding affinities of duplex and triplex DNA binders. This assay combines the high discrimination capabilities afforded by DNA-modified Au nanoparticles with the high-throughput capabilities of DNA microarrays. The detection and screening of duplex DNA binders are important because these molecules, in many cases, are potential anticancer agents as well as toxins. Triplex DNA binders are also promising drug candidates. These molecules, in conjunction with triplex forming oligonucleotides, could potentially be used to achieve control of gene expression by interfering with transcription factors that bind to DNA. Therefore, the ability to screen for these molecules in a high-throughput fashion could dramatically improve the drug screening process. The assay reported here provides excellent discrimination between strong, intermediate, and weak duplex and triplex DNA binders in a high-throughput fashion. PMID:17614366

  1. High-performance liquid chromatography-tandem mass spectrometry as a reference for analysis of tacrolimus to assess two immunoassays in patients with liver and renal transplants.

    PubMed

    Salm, P; Taylor, P J; Clark, A; Balderson, G A; Grygotis, A; Norris, R L; Lynch, S V; Shaw, L M; Pond, S M

    1997-12-01

    The accuracy and imprecision of three assays used for therapeutic monitoring of tacrolimus were tested using blood-containing weighed-in amounts of the drug, an enzyme-linked immunosorbent assay (ELISA), a microparticle enzyme immunoassay (MEIA I), and a high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS2) assay. Accuracy was acceptable for the HPLC-MS2 assay at all concentrations tested (< 10% deviation) and for the ELISA at 1.0 and 4.0 microg/l. Accuracy was not acceptable for the ELISA at 15.0 and 50.0 microg/l or for the MEIA I at all concentrations tested. Imprecision was acceptable for the HPLC-MS2 assay at all concentrations tested (coefficient of variation < 10%), for the ELISA at 15.0 and 50.0 microg/l, and for the MEIA I at 15.0 and 50.0 microg/l. Imprecision was not acceptable for the ELISA at 1.0 and 4.0 microg/l or for the MEIA I at 1.0 and 4.0 microg/l. This assessment with weighed-in amounts of tacrolimus verified the HPLC-MS2 assay as a reference method. The performance of the two immunoassays with HPLC-MS2 was then compared in the clinical setting using blood from patients with liver (n = 30) and renal (n = 37) transplants. In the liver transplant group (127 samples), the range of tacrolimus concentrations measured by HPLC-MS2, ELISA, and MEIA I was 1.9 to 31.8, 2.1 to 35.0, and less than 0.1 to 36.5 mg/l, respectively. In the renal transplant group (129 samples), the ranges were 1.7 to 26.1, 1.9 to 24.4, and 0.9 to 28.5 microg/l, respectively. Compared with the HPLC-MS2, the ELISA had minimal bias (0.1 to 0.2 microg/l) but unacceptable variability in values (SD > 13%). The MEIA I had unacceptable bias (1.7-1.8 microg/l) and variability (SD > 23%). These data indicated that neither the ELISA nor MEIA I is interchangeable with HPLC-MS2. Moreover, in view of the current trend to reduce the therapeutic dose of tacrolimus, quantitative results using the MEIA I would not be obtainable during therapeutic drug monitoring in some patients in whom effective therapeutic concentrations can be less than 5.0 microg/l.

  2. ELISA-PLA: A novel hybrid platform for the rapid, highly sensitive and specific quantification of proteins and post-translational modifications.

    PubMed

    Tong, Qing-He; Tao, Tao; Xie, Li-Qi; Lu, Hao-Jie

    2016-06-15

    Detection of low-abundance proteins and their post-translational modifications (PTMs) remains a great challenge. A conventional enzyme-linked immunosorbent assay (ELISA) is not sensitive enough to detect low-abundance PTMs and suffers from nonspecific detection. Herein, a rapid, highly sensitive and specific platform integrating ELISA with a proximity ligation assay (PLA), termed ELISA-PLA, was developed. Using ELISA-PLA, the specificity was improved by the simultaneous and proximate recognition of targets through multiple probes, and the sensitivity was significantly improved by rolling circle amplification (RCA). For GFP, the limit of detection (LOD) was decreased by two orders of magnitude compared to that of ELISA. Using site-specific phospho-antibody and pan-specific phospho-antibody, ELISA-PLA was successfully applied to quantify the phosphorylation dynamics of ERK1/2 and the overall tyrosine phosphorylation level of ERK1/2, respectively. ELISA-PLA was also used to quantify the O-GlcNAcylation of AKT, c-Fos, CREB and STAT3, which is faster and more sensitive than the conventional immunoprecipitation and western blotting (IP-WB) method. As a result, the sample consumption of ELISA-PLA was reduced 40-fold compared to IP-WB. Therefore, ELISA-PLA could be a promising platform for the rapid, sensitive and specific detection of proteins and PTMs. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. A novel double recognition enzyme-linked immunosorbent assay based on the nucleocapsid protein for early detection of European porcine reproductive and respiratory syndrome virus infection.

    PubMed

    Venteo, A; Rebollo, B; Sarraseca, J; Rodriguez, M J; Sanz, A

    2012-04-01

    Precise and rapid detection of porcine reproductive respiratory syndrome virus (PRRSV) infection in swine farms is critical. Improvement of control procedures, such as testing incoming gilt and surveillance of seronegative herds requires more rapid and sensitive methods. However, standard serological techniques detect mainly IgG antibodies. A double recognition enzyme-linked immunosorbent assay (DR-ELISA) was developed for detection of antibodies specific to European PRRSV. This new assay can recognize both IgM and IgG antibodies to PRSSV which might be useful for detecting in routine surveillance assays pigs that are in the very early stages of infection and missed by conventional assays detecting only IgG antibodies. DR-ELISA is based on the double recognition of antigen by antibody. In this study, the recombinant nucleocapsid protein (N) of PRRSV was used both as the coating and the enzyme-conjugated antigen. To evaluate the sensitivity of the assay at early stages of the infection, sera from 69 pigs infected with PRRSV were collected during successive days post infection (pi) and tested. While standard methods showed low sensitivity rates before day 14 pi, DR-ELISA detected 88.4% seropositive samples at day 7 showing greater sensitivity at early stages of the infection. Further studies were carried out to assess the efficiency of the new assay, and the results showed DR-ELISA to be a sensitive and accurate method for early diagnosis of EU-PRRSV infection. Copyright © 2012 Elsevier B.V. All rights reserved.

  4. 9 CFR 85.1 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... Immunosorbent Assay (ELISA) Test, except for approved differential pseudorabies tests other than the glycoprotein I (gpI) ELISA test; 5. Latex Agglutination Test (LAT); and 6. Particle Concentration Fluorescence...

  5. 9 CFR 85.1 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... Immunosorbent Assay (ELISA) Test, except for approved differential pseudorabies tests other than the glycoprotein I (gpI) ELISA test; 5. Latex Agglutination Test (LAT); and 6. Particle Concentration Fluorescence...

  6. 9 CFR 85.1 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... Immunosorbent Assay (ELISA) Test, except for approved differential pseudorabies tests other than the glycoprotein I (gpI) ELISA test; 5. Latex Agglutination Test (LAT); and 6. Particle Concentration Fluorescence...

  7. 9 CFR 85.1 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... Immunosorbent Assay (ELISA) Test, except for approved differential pseudorabies tests other than the glycoprotein I (gpI) ELISA test; 5. Latex Agglutination Test (LAT); and 6. Particle Concentration Fluorescence...

  8. 9 CFR 85.1 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Immunosorbent Assay (ELISA) Test, except for approved differential pseudorabies tests other than the glycoprotein I (gpI) ELISA test; 5. Latex Agglutination Test (LAT); and 6. Particle Concentration Fluorescence...

  9. Quantum dot-linked immunosorbent assay (QLISA) using orientation-directed antibodies.

    PubMed

    Suzuki, Miho; Udaka, Hikari; Fukuda, Takeshi

    2017-09-05

    An approach similar to the enzyme-linked immunosorbent assay (ELISA), with the advantage of saving time and effort but exhibiting high performance, was developed using orientation-directed half-part antibodies immobilized on CdSe/ZnS quantum dots. ELISA is a widely accepted assay used to detect the presence of a target substance. However, it takes time to quantify the target with specificity and sensitivity owing to signal amplification. In this study, CdSe/ZnS quantum dots are introduced as bright and photobleaching-tolerant fluorescent materials. Since hydrophilic surface coating of quantum dots rendered biocompatibility and functional groups for chemical reactions, the quantum dots were modified with half-sized antibodies after partial reduction. The half-sized antibody could be bound to a quantum dot through a unique thiol site to properly display the recognition domain for the core process of ELISA, which is an antigen-antibody interaction. The reducing conditions were investigated to generate efficient conjugates of quantum dots and half-sized antibodies. This was applied to IL-6 detection, as the quantification of IL-6 is significant owing to its close relationships with various biomedical phenomena that cause different diseases. An ELISA-like assay with CdSe/ZnS quantum dot institution (QLISA; Quantum dot-linked immunosorbent assay) was developed to detect 0.05ng/mL IL-6, which makes it sufficiently sensitive as an immunosorbent assay. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Development of 2 types of competitive enzyme-linked immunosorbent assay for detecting antibodies to the rinderpest virus using a monoclonal antibody for a specific region of the hemagglutinin protein.

    PubMed

    Khamehchian, S; Madani, R; Rasaee, M J; Golchinfar, F; Kargar, R

    2007-06-01

    A competitive enzyme-linked immunosorbent assay (C-ELISA) has been developed and standardized for the detection of antibodies to the rinderpest virus (RPV) in sera from cattle, sheep, and goats. The test is specific for rinderpest because it does not detect antibodies to peste-des-petits-ruminants virus (PPRV). The test depends on the ability of the monoclonal antibody (MAb) directed against the hemagglutinin (H) protein of RPV to compete with the binding of RPV antibodies in the positive serum to the H protein of this virus. This MAb recognized a region from amino acids 575 to 583 on the H protein of RPV that is unique to the RPV H protein and is not present on the hemagglutinin-neuraminidase protein of PPRV. Another C-ELISA (peptide C-ELISA) was set up using this specific region as an antigen. A threshold value of 64.4% inhibition was established for the RPV C-ELISA, with 90 known RPV-negative and 30 RPV-positive serum samples. Using common serum samples, a cutoff value of 43.0% inhibition for the peptide C-ELISA was established. Based on statistical analysis, the overall sensitivity and specificity of the RPV C-ELISA, relative to those of a commercial kit, were found to be 90.00% and 103.33%, respectively. However, the sensitivity and specificity of the peptide C-ELISA were found to be 180.00% and 73.33%, respectively. Although a common MAb in 2 new C-ELISA systems was used, variation in their percent inhibition, due to the use of different antigens, was observed. Taking into consideration the difference in percent inhibition of the 2 described assays and the commercial kit (50%), it was found that the RPV C-ELISA and the peptide C-ELISA are more specific and sensitive tools than the commercial kit for assessing herd immune status and for epidemiologic surveillance.

  11. DARPA Antibody Technology Program. Standardized Test Bed for Antibody Characterization: Characterization of an MS2 ScFv Antibody Produced by Illumina

    DTIC Science & Technology

    2016-08-01

    platforms. 15. SUBJECT TERMS Antibody Antibody Technology Program (ATP) Quality Enzyme-linked immunosorbent assay ( ELISA ) Biosurveillance Single-chain...2.6 Thermal Stress Test............................................................................................4 2.7 ELISA ...3.5 ELISA Results .................................................................................................11 3.6 SPR Results

  12. 42 CFR 71.53 - Requirements for importers of nonhuman primates.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Trade in Endangered Species. ELISA means enzyme-linked immunosorbent assay, a type of laboratory test... serum for immunoglobulin G (IgG) antibodies to filovirus by using an ELISA methodology, or other method... for filovirus antigen by using the antigen-capture ELISA method must be submitted to a qualified...

  13. Assessment of an ELISA Laboratory Exercise

    ERIC Educational Resources Information Center

    Robinson, David L.; Lau, Joann M.

    2012-01-01

    The enzyme-linked immunosorbent assay (ELISA) is a powerful immunological technique for quantifying small amounts of compounds and has been used in research and clinical settings for years. Although there are laboratory exercises developed to introduce the ELISA technique to students, their ability to promote student learning has not been…

  14. 42 CFR 71.53 - Requirements for importers of nonhuman primates.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Trade in Endangered Species. ELISA means enzyme-linked immunosorbent assay, a type of laboratory test... serum for immunoglobulin G (IgG) antibodies to filovirus by using an ELISA methodology, or other method... for filovirus antigen by using the antigen-capture ELISA method must be submitted to a qualified...

  15. AN ENZYME LINKED IMMUNOSORBENT ASSAY (ELISA) METHOD FOR MONITORING 2,4 DICHLOROPHENOXYACETIC ACID (2,4-D) EXPOSURES

    EPA Science Inventory

    Abstract describes a streamlined ELISA method developed to quantitatively measure 2,4-D in human urine samples. Method development steps and comparison with gas chromatography/mass spectrometry are presented. Results indicated that the ELISA method could be used as a high throu...

  16. Comparison of the presence of Shiga toxin 1 in food matrices as determined by an enzyme-linked immunosorbent assay and a biological activity assay.

    PubMed

    Lumor, Stephen E; Fredrickson, Neal R; Ronningen, Ian; Deen, Bronwyn D; Smith, Kenneth; Diez-Gonzalez, Francisco; Labuza, Theodore P

    2012-06-01

    This study was conducted to compare the identification of Shiga toxin 1 (Stx1) based on its specific biological activity and based on results of a commercial enzyme-linked immunosorbent assay (ELISA) kit. Stx1 was thermally treated for various periods in phosphate-buffered saline, milk, and orange juice. The residual Stx1 concentration was determined with the commercial ELISA kit, and its residual enzymatic activity (amount of adenine released from a 2,551-bp DNA substrate) was determined with a biological activity assay (BAA). Regression analysis indicated that the inactivation of Stx1 as a function of time followed first-order kinetics. The half-lives determined at 60, 65, 70, 75, 80, and 85°C were 9.96, 3.19, 2.67, 0.72, 0.47, and 0.29 min, respectively, using the BAA. The half-lives determined by the ELISA with thermal treatments at 70, 75, 80, and 85°C were 40.47, 11.03, 3.64, and 1.40 min, respectively. The Z, Q(10), and Arrhenius activation energy values derived by both assays were dissimilar, indicating that the rate of inactivation of the active site of Stx1 was less sensitive to temperature change than was denaturation of the epitope(s) used in the ELISA. These values were 10.28°C and 9.40 and 54.70 kcal/mol, respectively, with the ELISA and 16°C and 4.11 and 34 kcal/mol, respectively, with the BAA. Orange juice enhanced Stx1 inactivation as a function of increasing temperature, whereas inactivation in 2% milk was not very much different from that in phosphate-buffered saline. Our investigation indicates that the ELISA would be a reliable method for detecting the residual toxicity of heat-treated Stx1 because the half-lives determined with the ELISA were greater than those determined with the BAA (faster degradation) at all temperatures and were highly correlated (R(2) = 0.994) with those determined with the BAA.

  17. Rapid Spoligotyping of Mycobacterium tuberculosis Complex Bacteria by Use of a Microarray System with Automatic Data Processing and Assignment

    PubMed Central

    Ruettger, Anke; Nieter, Johanna; Skrypnyk, Artem; Engelmann, Ines; Ziegler, Albrecht; Moser, Irmgard; Monecke, Stefan; Ehricht, Ralf

    2012-01-01

    Membrane-based spoligotyping has been converted to DNA microarray format to qualify it for high-throughput testing. We have shown the assay's validity and suitability for direct typing from tissue and detecting new spoligotypes. Advantages of the microarray methodology include rapidity, ease of operation, automatic data processing, and affordability. PMID:22553239

  18. Rapid spoligotyping of Mycobacterium tuberculosis complex bacteria by use of a microarray system with automatic data processing and assignment.

    PubMed

    Ruettger, Anke; Nieter, Johanna; Skrypnyk, Artem; Engelmann, Ines; Ziegler, Albrecht; Moser, Irmgard; Monecke, Stefan; Ehricht, Ralf; Sachse, Konrad

    2012-07-01

    Membrane-based spoligotyping has been converted to DNA microarray format to qualify it for high-throughput testing. We have shown the assay's validity and suitability for direct typing from tissue and detecting new spoligotypes. Advantages of the microarray methodology include rapidity, ease of operation, automatic data processing, and affordability.

  19. Microarray-based screening of heat shock protein inhibitors.

    PubMed

    Schax, Emilia; Walter, Johanna-Gabriela; Märzhäuser, Helene; Stahl, Frank; Scheper, Thomas; Agard, David A; Eichner, Simone; Kirschning, Andreas; Zeilinger, Carsten

    2014-06-20

    Based on the importance of heat shock proteins (HSPs) in diseases such as cancer, Alzheimer's disease or malaria, inhibitors of these chaperons are needed. Today's state-of-the-art techniques to identify HSP inhibitors are performed in microplate format, requiring large amounts of proteins and potential inhibitors. In contrast, we have developed a miniaturized protein microarray-based assay to identify novel inhibitors, allowing analysis with 300 pmol of protein. The assay is based on competitive binding of fluorescence-labeled ATP and potential inhibitors to the ATP-binding site of HSP. Therefore, the developed microarray enables the parallel analysis of different ATP-binding proteins on a single microarray. We have demonstrated the possibility of multiplexing by immobilizing full-length human HSP90α and HtpG of Helicobacter pylori on microarrays. Fluorescence-labeled ATP was competed by novel geldanamycin/reblastatin derivatives with IC50 values in the range of 0.5 nM to 4 μM and Z(*)-factors between 0.60 and 0.96. Our results demonstrate the potential of a target-oriented multiplexed protein microarray to identify novel inhibitors for different members of the HSP90 family. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. Evaluation of a broad-ranging and convenient enzyme-linked immunosorbent assay using the lysate of infected cells with five serotypes of Orientia tsutsugamushi, a causative agent of scrub typhus.

    PubMed

    Ogawa, Motohiko; Satoh, Masaaki; Saijo, Masayuki; Ando, Shuji

    2017-01-05

    Scrub typhus is a mite-borne rickettsiosis caused by infection of Orientia tsutsugamushi, which is endemic to several Asia-Pacific Rim countries, including Japan. Although micro-indirect immunofluorescent assay (micro-IFA) is the standard method for the serological diagnosis of scrub typhus, enzyme-linked immunosorbent assay (ELISA) is considered to be more objective, by providing digitized results as opposed to being subject to the judgment of the evaluator as in micro-IFA. Therefore, the aim of this study was to develop a broad-ranging ELISA using the five major prevalent serotypes of O. tsutsugamushi in Japan as the antigens. Furthermore, in contrast to previous studies that used purified microorganisms via ultracentrifugation, we directly used the infected cells, and evaluated the diagnostic accuracy of this simplified method to that of micro-IFA. Evaluation of paired patient sera against the five serotypes showed that the accuracy of ELISA relative to micro-IFA was 87.4 and 79.5% for immunoglobulin (Ig)M and IgG assays, respectively, at the optimized cut-off value. Further evaluation of patient sera against the expected serotype of the infecting strain showed that the accuracy of ELISA compared to micro-IFA increased to 100 and 97.4% in the IgM and IgG assays, respectively. This suggests that use of the five prevalent serotypes contributed to the increase of the accuracy of ELISA. When applying the criteria of serological diagnosis for paired sera samples to ELISA, all 19 patients were diagnosed as positive; a ≥4-fold elevation of the antibody titer was observed in 15 of 19 patients that were positive, and very high antibody titers were observed in both paired sera samples of the remaining four patients. In addition, all samples of healthy subjects and patients with other types of rickettsiosis were diagnosed as negative using these criteria. Our results suggest the excellent performance of the new broad-ranging and convenient ELISA, which appears to be applicable for the diagnosis of scrub typhus patients infected with the wide variety of prevalent strains in Japan. Furthermore, the ELISA is more objective than the micro-IFA, and can therefore provide more accurate diagnoses in Japan.

  1. Usefulness of Enzyme-linked Immunosorbent Assay Using Recombinant BP180 and BP230 for Serodiagnosis and Monitoring Disease Activity of Bullous Pemphigoid

    PubMed Central

    Lee, Eui Hyung; Kim, Yeon Hee; Kim, Sinyoung; Kim, Song-ee

    2012-01-01

    Background Bullous pemphigoid (BP) is an autoimmune subepidermal bullous disease associated with autoantibodies against BP180 and BP230. Enzyme-linked immunosorbent assay (ELISA) is a sensitive tool for the detection of immunoglobulin G (IgG) anti-BP180 and anti-BP230 autoantibodies. Objective The aim of this study was to evaluate the usefulness of ELISA for diagnosing and monitoring the disease activity of BP. Methods We evaluated serum IgG levels of anti-BP180 and anti-BP230 autoantibodies in 47 BP patients, 16 epidermolysis bullosa aquisita patients, and 15 healthy volunteers using ELISA. Through retrospective review of the medical records, the clinical characteristics of BP including disease activity, duration, pruritus severity and peripheral blood eosinophil counts were assessed. Results The sensitivity of BP180 ELISA was 97.9%, BP230 ELISA 72.3%, and a combination of the two was 100%. The specificity of BP180 ELISA was 90.3%, BP230 ELISA 100%, and a combination of the two was 90.3%. BP180 ELISA scores showed strong associations with disease activity, pruritus severity, peripheral blood eosinophil counts, and disease duration, whereas BP230 ELISA scores did not. Conclusion BP180 and BP230 ELISAs are highly sensitive methods for the diagnosis of BP, and BP180 ELISA, in particular, is a sensitive tool for monitoring the disease activity of BP. PMID:22363155

  2. A chromogranin A ELISA absent of an apparent high-dose hook effect observed in other chromogranin A ELISAs.

    PubMed

    Erickson, J Alan; Grenache, David G

    2016-01-15

    Routine testing for chromogranin A (CgA) using an established commercial ELISA revealed an apparent high-dose hook effect in approximately 15% of specimens. Investigations found the same effect in two additional ELISAs. We hypothesized that a CgA derived peptide(s) at high concentrations was responsible but experiments were inconclusive. Here we describe the analytical performance characteristics of the Chromoa™ CgA ELISA that did not display the apparent high-dose hook effect. Performance characteristics of the Chromoa ELISA were assessed. The reference interval was established utilizing healthy volunteers. Specimens producing the apparent high-dose hook effect in other assays were evaluated using the Chromoa ELISA. The limit of detection was 8ng/ml. Linearity was acceptable (slope=1.04, intercept=18.1 and r(2)=0.997). CVs were ≤4.6 and ≤9.3% for repeatability and within-laboratory imprecision, respectively. CgA was stable at ambient and refrigerated temperatures for a minimum of two and 14days, respectively. An upper reference interval limit of 95ng/ml was established. Specimens demonstrating the apparent high-dose hook effect in other ELISAs did not exhibit the phenomenon using the Chromoa ELISA. The Chromoa ELISA demonstrates acceptable performance for quantifying serum CgA. The apparent high-dose hook effect exhibited in other ELISAs was absent using the Chromoa assay. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Novel lectin-independent approach to detect galactose-deficient IgA1 in IgA nephropathy.

    PubMed

    Yasutake, Junichi; Suzuki, Yusuke; Suzuki, Hitoshi; Hiura, Naoko; Yanagawa, Hiroyuki; Makita, Yuko; Kaneko, Etsuji; Tomino, Yasuhiko

    2015-08-01

    Galactose-deficient IgA1 (Gd-IgA1) is a critical effector molecule in the pathogenesis of IgA nephropathy (IgAN). Although many researchers have measured serum levels of Gd-IgA1 using snail helix aspersa agglutinin (HAA) lectin-based assay, the lectin-dependent assay has some serious problems in robustness. In this study, we aimed to establish a more robust and stable enzyme-linked immunosorbent assay (ELISA) method that uses a specific monoclonal antibody to recognize a hinge region in human Gd-IgA1 (Gd-IgA1 ELISA). Rats were immunized with human Gd-IgA1 hinge region peptide to obtain Gd-IgA1-specific monoclonal antibody KM55. Gd-IgA1 ELISA for specifically detecting serum Gd-IgA1 was consequently constructed. Serum Gd-IgA1 concentrations in human subjects were measured using KM55 ELISA assay. To further confirm specificity of the Gd-IgA1-specific antibody, KM55 was also applied for immunofluorescence staining of glomerular Gd-IgA1 in paraffin-embedded sections of renal biopsy specimens. Measurement of serum levels of Gd-IgA1 in human subjects by Gd-IgA1 ELISA revealed increased serum Gd-IgA1 level in patients with IgAN compared with patients with other renal diseases or non-renal diseases. Importantly, the results obtained from Gd-IgA1 ELISA positively correlated with those from the HAA lectin-based assay (R = 0.75). Immunofluorescence staining of renal biopsy specimens with KM55 detected glomerular co-localization of Gd-IgA1 and IgA. This novel lectin-independent method with KM55 for measuring serum levels of Gd-IgA1 can pave the way for more convincing diagnosis and activity assessment of IgAN, and can expedite clinical research to better understand this difficult disease. © The Author 2015. Published by Oxford University Press on behalf of ERA-EDTA.

  4. Novel lectin-independent approach to detect galactose-deficient IgA1 in IgA nephropathy

    PubMed Central

    Yasutake, Junichi; Suzuki, Yusuke; Suzuki, Hitoshi; Hiura, Naoko; Yanagawa, Hiroyuki; Makita, Yuko; Kaneko, Etsuji; Tomino, Yasuhiko

    2015-01-01

    Background Galactose-deficient IgA1 (Gd-IgA1) is a critical effector molecule in the pathogenesis of IgA nephropathy (IgAN). Although many researchers have measured serum levels of Gd-IgA1 using snail helix aspersa agglutinin (HAA) lectin-based assay, the lectin-dependent assay has some serious problems in robustness. In this study, we aimed to establish a more robust and stable enzyme-linked immunosorbent assay (ELISA) method that uses a specific monoclonal antibody to recognize a hinge region in human Gd-IgA1 (Gd-IgA1 ELISA). Methods Rats were immunized with human Gd-IgA1 hinge region peptide to obtain Gd-IgA1-specific monoclonal antibody KM55. Gd-IgA1 ELISA for specifically detecting serum Gd-IgA1 was consequently constructed. Serum Gd-IgA1 concentrations in human subjects were measured using KM55 ELISA assay. To further confirm specificity of the Gd-IgA1-specific antibody, KM55 was also applied for immunofluorescence staining of glomerular Gd-IgA1 in paraffin-embedded sections of renal biopsy specimens. Results Measurement of serum levels of Gd-IgA1 in human subjects by Gd-IgA1 ELISA revealed increased serum Gd-IgA1 level in patients with IgAN compared with patients with other renal diseases or non-renal diseases. Importantly, the results obtained from Gd-IgA1 ELISA positively correlated with those from the HAA lectin-based assay (R = 0.75). Immunofluorescence staining of renal biopsy specimens with KM55 detected glomerular co-localization of Gd-IgA1 and IgA. Conclusion This novel lectin-independent method with KM55 for measuring serum levels of Gd-IgA1 can pave the way for more convincing diagnosis and activity assessment of IgAN, and can expedite clinical research to better understand this difficult disease. PMID:26109484

  5. Evaluation of five enzyme immunoassays compared with the cytotoxicity assay for diagnosis of Clostridium difficile-associated diarrhea in dogs.

    PubMed

    Chouicha, Nadira; Marks, Stanley L

    2006-03-01

    Clostridium difficile-associated-diarrhea (CDAD) is a nosocomial infection in dogs. Diagnosis of this infection is dependent on clinical signs of disease supported by laboratory detection of C. difficile toxins A or B, or both, in fecal specimens via enzyme-linked immunosorbent assay (ELISA). Unfortunately, to the authors' knowledge, commercially available ELISAs have not been validated in dogs to date. We evaluated 5 ELISAs done on 143 canine fecal specimens (100 diarrheic and 43 nondiarrheic dogs) and on 29 C. difficile isolates. The results of each ELISA were compared with the cytotoxin B tissue culture assay (CTA). Clostridium difficile was isolated from 23% of the fecal specimens. Eighteen of the 143 fecal specimens were toxin positive (15 diarrheic and 3 nondiarrheic dogs). On the basis of multiplex polymerase chain reaction (PCR) analysis for toxin-A and -B genes, 72% of the isolates were toxigenic. The carriage rate of toxigenic isolates in diarrheic dogs was higher than that in the nondiarrheic dogs; however, these differences were not statistically significant. A good correlation was found between CTA, PCR, and culture results. The ELISAs done on fecal specimens collected from diarrheic dogs had low sensitivity (7-33%). In contrast, ELISA for toxin A or B, or both, performed on toxigenic isolates had high sensitivity (93%). These results suggest that commercially available human ELISAs are inadequate for the diagnosis of canine C. difficile-associated diarrhea when tested on fecal specimens. In contrast, the Premier ToxinA/B and Techlab ToxinA/B ELISAs may be useful for the diagnosis of canine CDAD when used on toxigenic isolates.

  6. Optimized enzyme-linked immunosorbent assay for detecting cytomegalovirus infections during clinical trials of recombinant vaccines.

    PubMed

    Pagnon, Anke; Piras, Fabienne; Gimenez-Fourage, Sophie; Dubayle, Joseline; Arnaud-Barbe, Nadège; Hessler, Catherine; Caillet, Catherine

    2017-11-01

    In clinical trials of cytomegalovirus (CMV) glycoprotein B (gB) vaccines, CMV infection is detected by first depleting serum of anti-gB antibodies and then measuring anti-CMV antibodies with a commercially available enzyme-linked immunosorbent assay (ELISA) kit, with confirmation of positive findings by immunoblot. Identification of CMV immunoantigens for the development of an ELISA that detects specifically CMV infection in clinical samples from individuals immunized with gB vaccines. Sensitivity and specificity of ELISAs using antigenic regions of CMV proteins UL83/pp65, UL99/pp28, UL44/pp52, UL80a/pp38, UL57, and UL32/pp150 were measured. An IgG ELISA using a UL32/pp150 [862-1048] capture peptide was the most specific (93.7%) and sensitive (96.4%) for detecting CMV-specific antibodies in sera. The ELISA successfully detected CMV-specific antibodies in 22 of 22 sera of subjects who had been vaccinated with a gB vaccine but who had later been infected with CMV. The ELISA was linear over a wide range of CMV concentrations (57-16,814 ELISA units/mL) and was reproducible as indicated by a 5% intra-day and 7% inter-day coefficients of variation. The signal was specifically competed by UL32/pp150 [862-1048] peptide but not by CMV-gB or herpes simplex virus 2 glycoprotein D. Lipid and hemoglobin matrix did not interfere with the assay. The UL32/pp150 [862-1048] IgG ELISA can be used for the sensitive and specific detection of CMV infection in gB-vaccinated individuals. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Recombinant nucleocapsid protein-based enzyme-linked immunosorbent assay for detection of antibody to turkey coronavirus.

    PubMed

    Abdelwahab, Mohamed; Loa, Chien Chang; Wu, Ching Ching; Lin, Tsang Long

    2015-06-01

    Nucleocapsid (N) protein gene of turkey coronavirus (TCoV) was expressed in a prokaryotic system and used to develop an enzyme-linked immunosorbent assay (ELISA) for detection of antibody to TCoV. Anti-TCoV hyperimmune turkey serum and normal turkey serum were used as positive or negative controls for optimization of the ELISA. Goat anti-turkey IgG (H+L) conjugated with horseradish peroxidase was used as detector antibody. Three hundred and twenty two turkey sera from the field were used to evaluate the performance of ELISA and determine the cut-off point of ELISA. The established ELISA was also examined with serum samples obtained from turkeys experimentally infected with TCoV. Those serum samples were collected at various time intervals from 1 to 63 days post-infection. The optimum conditions for differentiation between anti-TCoV hyperimmune serum and normal turkey serum were recombinant TCoV N protein concentration at 20 μg/ml, serum dilution at 1:800, and conjugate dilution at 1:10,000. Of the 322 sera from the field, 101 were positive for TCoV by immunofluorescent antibody assay (IFA). The sensitivity and specificity of the ELISA relative to IFA test were 86.0% and 96.8%, respectively, using the optimum cut-off point of 0.2 as determined by logistic regression method. Reactivity of anti-rotavirus, anti-reovirus, anti-adenovirus, or anti-enterovirus antibodies with the recombinant N protein coated on the ELISA plates was not detected. These results indicated that the established antibody-capture ELISA in conjunction with recombinant TCoV N protein as the coating protein can be utilized for detection of antibodies to TCoV in turkey flocks. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. Evaluation of the technical performance of novel holotranscobalamin (holoTC) assays in a multicenter European demonstration project.

    PubMed

    Morkbak, Anne L; Heimdal, Randi M; Emmens, Kathleen; Molloy, Anne; Hvas, Anne-Mette; Schneede, Joern; Clarke, Robert; Scott, John M; Ueland, Per M; Nexo, Ebba

    2005-01-01

    A commercially available holotranscobalamin (holo-TC) radioimmunoassay (RIA) (Axis-Shield, Dundee, Scotland) was evaluated in four laboratories and compared with a holoTC ELISA run in one laboratory. The performance of the holoTC RIA assay was comparable in three of the four participating laboratories. The results from these three laboratories, involving at least 20 initial runs of "low", "medium" and "high" serum-based controls (mean holoTC concentrations 34, 60 and 110 pmol/L, respectively) yielded an intra-laboratory imprecision of 6-10%. No systematic inter-laboratory deviations were observed on runs involving 72 patient samples (holoTC concentration range 10-160 pmol/L). A fourth laboratory demonstrated higher assay imprecision for control samples and systematic deviation of results for the patient samples. Measurement of holoTC by ELISA showed an imprecision of 4-5%, and slightly higher mean values for the controls (mean holoTC concentrations 40, 70 and 114 pmol/L, respectively). Comparable results were obtained for the patient samples. The long-term intra-laboratory imprecision was 12% for the holoTC RIA and 6% for the ELISA. In conclusion, it would be prudent to check the calibration and precision prior to starting to use these holoTC assays in research or clinical practice. The results obtained using the holoTC RIA were similar to those obtained using the holoTC ELISA assay.

  9. Evaluation of a caprine arthritis-encephalitis virus/maedi-visna virus indirect enzyme-linked immunosorbent assay in the serological diagnosis of ovine progressive pneumonia virus in U.S. sheep

    USDA-ARS?s Scientific Manuscript database

    Serological diagnostic testing of sheep and goats using enzyme immunosorbent assays (ELISAs) is the most common method of determining small ruminant lentivirus (SRLV) infection. A caprine arthritis-encephalitis virus (CAEV)/maedi-visna virus (MVV) indirect (i) ELISA, which utilizes MVV EV1 capsid a...

  10. Validation of an indirect ELISA to detect antibodies against BoHV-1 in bovine and guinea-pig serum samples using ISO/IEC 17025 standards.

    PubMed

    Parreño, Viviana; Romera, S Alejandra; Makek, Lucia; Rodriguez, Daniela; Malacari, Darío; Maidana, Silvina; Compaired, Diego; Combessies, Gustavo; Vena, María Marta; Garaicoechea, Lorena; Wigdorovitz, Andrés; Marangunich, Laura; Fernandez, Fernando

    2010-10-01

    Two ELISAs to quantify antibodies to BoHV-1 in the sera of cattle and immunized guinea pigs were developed and validated using ISO/IEC 17025 standards. The cut-off value of the assay was established at 20% positivity of a high positive control for screening of cattle. Using this threshold, the assay properly classified the OIE bovine reference sera EU1, EU2 and EU3. For vaccine potency testing, a cut-off of 40% was selected for both species. The reliability of the assays, given by their diagnostic sensitivity and specificity, using the threshold of 40% was 89.7% and 100%, respectively, for bovines and 94.9% and 100% for guinea pigs, respectively. There was almost perfect agreement between the ELISA and virus neutralization results. In addition, after vaccination, there was a good correlation between the neutralizing and ELISA antibody titers of the serum from the same bovine or guinea pig, sampled at 60 and 30 days post-vaccination, respectively (R(bovine)=0.88, R(guinea pig)=0.92; p<0.0001). A similar correlation was observed when analyzing the mean antibody titers of groups of vaccinated animals (R(bovine)=0.95 and R(guinea pig)=0.97; p<0.0001), indicating the relevance of the ELISAs for batch to batch vaccine potency testing in the target species and in the laboratory animal model. The intermediate precision of the assays expressed as the relative coefficient of variation (CV) of the positive control assayed over a 3-year period in the same laboratory was 22.2% for bovines and 23.1% for guinea pigs. The reproducibility of both techniques obtained in inter-laboratory assays was CV=12.4% for bovines and CV approximately 0 for guinea pigs, which met the requirements of the OIE (CV<30%). The validated ELISAs represent important methods for vaccine potency testing and for controlling BoHV-1 infections. Copyright (c) 2010 Elsevier B.V. All rights reserved.

  11. Detection of toxoplasma-specific immunoglobulin G in human sera: performance comparison of in house Dot-ELISA with ECLIA and ELISA.

    PubMed

    Teimouri, Aref; Modarressi, Mohammad Hossein; Shojaee, Saeedeh; Mohebali, Mehdi; Zouei, Nima; Rezaian, Mostafa; Keshavarz, Hossein

    2018-05-08

    In the current study, performance of electrochemiluminescence immunoassay (ECLIA) in detection of anti-toxoplasma IgG in human sera was compared with that of enzyme-linked immunosorbent assay (ELISA). Furthermore, performance of an in house Dot-ELISA in detection of anti-toxoplasma IgG was compared with that of ECLIA and ELISA. In total, 219 human sera were tested to detect anti-toxoplasma IgG using Dynex DS2® and Roche Cobas® e411 Automated Analyzers. Discordant results rechecked using immunofluorescence assay (IFA). Then, sera were used in an in house Dot-ELISA to assess toxoplasma-specific IgG. Of the 219 samples, two samples were found undetermined using ECLIA but reactive using ELISA. Using IFA, the two sera were reported unreactive. Furthermore, two samples were found reactive using ECLIA and unreactive using ELISA. These samples were reported reactive using IFA. The overall agreement for the two former methods was 98% (rZ0.98.1; P < 0.001). The intrinsic parameters calculated for in house Dot-ELISA included sensitivity of 79.5, specificity of 78.2, and accuracy of 78.9%, compared to ECLIA and ELISA. Positive and negative predictive values included 82.9 and 74.2%, respectively. A 100% sensitivity was found in in house Dot-ELISA for highly reactive sera in ECLIA and ELISA. ECLIA is appropriate for the first-line serological screening tests and can replace ELISA due to high speed, sensitivity, and specificity, particularly in large laboratories. Dot-ELISA is a rapid, sensitive, specific, cost-effective, user-friendly, and field-portable technique and hence can be used for screening toxoplasmosis, especially in rural fields or less equipped laboratories.

  12. Lipase member H is a novel secreted protein selectively upregulated in human lung adenocarcinomas and bronchioloalveolar carcinomas

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Seki, Yasuhiro; Research Center for Stem Cell Engineering, National Institute of Advanced Industrial Science and Technology; Yoshida, Yukihiro

    2014-01-24

    Highlights: • Most of the adenocarcinomas and bronchioloalveolar carcinomas were LIPH-positive. • LIPH is necessary for the proliferation of lung cancer cells in vitro. • A high level of LIPH in serum is correlated with better survival in early phase lung-cancer patients after surgery. - Abstract: Lung cancer is one of the most frequent causes of cancer-related death worldwide. However, molecular markers for lung cancer have not been well established. To identify novel genes related to lung cancer development, we surveyed publicly available DNA microarray data on lung cancer tissues. We identified lipase member H (LIPH, also known as mPA-PLA1)more » as one of the significantly upregulated genes in lung adenocarcinoma. LIPH was expressed in several adenocarcinoma cell lines when they were analyzed by quantitative real-time polymerase chain reaction (qPCR), western blotting, and sandwich enzyme-linked immunosorbent assay (ELISA). Immunohistochemical analysis detected LIPH expression in most of the adenocarcinomas and bronchioloalveolar carcinomas tissue sections obtained from lung cancer patients. LIPH expression was also observed less frequently in the squamous lung cancer tissue samples. Furthermore, LIPH protein was upregulated in the serum of early- and late-phase lung cancer patients when they were analyzed by ELISA. Interestingly, high serum level of LIPH was correlated with better survival in early phase lung cancer patients after surgery. Thus, LIPH may be a novel molecular biomarker for lung cancer, especially for adenocarcinoma and bronchioloalveolar carcinoma.« less

  13. Enzyme-Linked Immunosorbent Assay (ELISA).

    PubMed

    Konstantinou, George N

    2017-01-01

    Food allergy is a public health concern especially after recognizing its constantly increased prevalence and severity. Despite careful reading of food ingredient statements, food allergic individuals may experience reactions caused by "hidden", "masked", or "contaminated" proteins that are known major allergens. Many techniques have been developed to detect even small traces of food allergens, for clinical or laboratory purposes. Enzyme-linked immunosorbent assay (ELISA) is one of the best validated and most routinely used immunoassay in allergy research, in allergy diagnosis in allergy-related quality control in various industries. Although as a technique it has been implemented for the last 45 years, the evolution in biochemistry allowed the development of ultrasensitive ELISA variations that are capable of measuring quantities in the scale of picograms, rendering ELISA attractive, robust, and very famous.

  14. Development and preliminary application of an indirect ELISA for detecting antibodies against Avian Influenza Virus.

    PubMed

    Wang, G; Ding, J; Hu, S; Yang, X

    2012-10-01

    Fragment of 759 bp DNA spanning the Matrix 1 (M1) gene of Avian Influenza Virus (AIV) was inserted into an expression vector pET28c to construct a recombinant plasmid pET28c-M1. The pET28c-M1 plasmid was transformed into the Escherichia coli BL21 (DE3) competent cell to produce a recombinant strain E. coli 21 (DE3). After being induced by Isopropyl-b-D-galactopyranoside (IPTG), E. coli 21 (DE3) expressed a 28-kDa fusion protein at a high level. This protein can bind anti-AIV (H5N1) positive serum by Western-blot analysis. After being denatured, renatured, and purified by Ni(2+)-column, the fusion protein was used as an antigen to develop Matrix 1 Enzyme-Linked Immunosorbent Assay (M1-ELISA) for detecting antibodies against AIV from chicken serum. We found that this indirect M1-ELISA was sensitive for differentiating antisera against AIV and antisera against other six kinds of avian viruses apart from AIV and this method is more sensitive than Hemagglutination Inhibition (HI) test. When compared with HI test and ELISA (IDEXX) in evaluating 581 serum samples from field vaccinated chickens, this assay showed 93.3% agreement ratio with the HI test, as well as 96.0% agreement ratio with ELISA (IDEXX). In a preliminary application, the assay successfully detected 19 AIVs from 51 nonvaccinated chicken lungs. It concludes that an indirect ELISA was successfully developed for detecting AIV. The assay is specific and sensitive. The application will greatly contribute to the long-term prevention and control of avian influenza in China. Copyright © 2011 Elsevier Ltd. All rights reserved.

  15. Expression, purification of metallothionein genes from freshwater crab (Sinopotamon yangtsekiense) and development of an anti-metallothionein ELISA

    PubMed Central

    Zhang, Hao; Zhou, Hui

    2017-01-01

    Using the phoA-fusion technology, the recombinant metallothionein (MT) from freshwater crab (Sinopotamon yangtsekiense) has been successfully produced in Escherichia coli. MT purified from the bacterial suspension showed one polypeptide with a molecular weight of 7 kDa by tricine-sodium dodecyl sulfate-polyacrylamide gel electrophoresis (Tricine-SDS-PAGE). Western-blotting confirmed the polypeptides had a specific reactivity with mouse polyclonal MT anti-serum. Based on the purified MT and MT anti-serum, the reaction parameters for an enzyme-linked immunosorbent assay (ELISA) were developed. The direct coating ELISA showed a higher linear relationship compared to antibody sandwich coating ELISA. The optimal dilution rates of purified MT anti-serum and coating period were shown to be 1:160,000 and 12 hours at 4°C. At 37°C, the appropriate reaction duration of the first antibody and the second antibody were 2 hours and 1 hour, respectively. According to these optimal parameters, the standard linear equation, y = 0.0032x + 0.1769 (R2 = 0.9779, x, y representing MT concentration and OD450 value), was established for the determination of MT concentration with a valid range of 3.9–500 ng/ml. In verification experiments, the mean coefficients of variation of the intra-assay and inter-assay were 3.260% and 3.736%, respectively. According to the result of MT recovery, ELISA with an approaching 100% MT recovery was more reliable and sensitive than the Cd saturation assay. In conclusion, the newly developed ELISA of this study was precise, stable and repeatable, and could be used as a biomarker tool to monitor pollution by heavy metals. PMID:28350826

  16. Use of the Falcon assay screening test--enzyme-linked immunosorbent assay (FAST-ELISA) and the enzyme-linked immunoelectrotransfer blot (EITB) to determine the prevalence of human fascioliasis in the Bolivian Altiplano.

    PubMed

    Hillyer, G V; Soler de Galanes, M; Rodriguez-Perez, J; Bjorland, J; Silva de Lagrava, M; Ramirez Guzman, S; Bryan, R T

    1992-05-01

    A collaborative study between the University of Puerto Rico School of Medicine, the Centers for Disease Control, the Bolivian Ministry of Health, and private voluntary organizations (Foster Parents Plan International and Danchurchaid) working in Bolivia has identified a region in the northwestern Altiplano of Bolivia near Lake Titicaca as harboring the highest prevalence of human fascioliasis in the world reported to date. Two serologic techniques (the Falcon assay screening test-enzyme-linked immunosorbent assay [FAST-ELISA] and the enzyme-linked immunoelectrotransfer blot [EITB]) were used in the determination of its prevalence. One hundred serum samples and 73 stool samples were obtained from Aymara Indians from Corapata, Bolivia. Antibody absorbance levels to Fasciola hepatica excretion-secretion antigens were compared with EITB banding patterns using the same antigen preparation. A positive FAST-ELISA result was defined as an absorbance value greater than the mean plus three standard deviations of two sets of normal negative controls (Puerto Rican and Bolivian). Using this criterion, 53 of 100 sera tested were found positive by this technique. Within this group, 19 (95%) of 20 individuals who were parasite positive were also positive by FAST-ELISA. An additional 24 individuals who were negative for F. hepatica eggs and 10 individuals for whom no specimens were received were also positive by FAST-ELISA. Among the 53 individuals negative for F. hepatica eggs, 29 were also negative by FAST-ELISA. The EITB analysis of the sera from confirmed infected individuals revealed at least three F. hepatica (Fh) bands with molecular weights of 12, 17, and 63 kD, respectively.(ABSTRACT TRUNCATED AT 250 WORDS)

  17. Development of a direct competitive enzyme-linked immunosorbent assay for parathion residue in food samples.

    PubMed

    Gui, Wen-Jun; Liu, Yi-Hua; Wang, Chun-Mei; Liang, Xiao; Zhu, Guo-Nian

    2009-10-01

    A heterologous direct competitive enzyme-linked immunosorbent assay (ELISA) for parathion residue determination is described based on a monoclonal antibody and a new competitor. The effects of several physicochemical factors, such as methanol concentration, ionic strength, pH value, and sample matrix, on the performance of the ELISA were optimized for the sake of obtaining a satisfactory assay sensitivity. Results showed that when the assay medium was in the optimized condition (phosphate buffer solution [PBS] containing 10% [v/v] methanol and 0.2 mol/L NaCl at a pH value of 5.0), the sensitivity (estimated as the IC(50) value) and the limit of detection (LOD, estimated as the IC(10) value) were 1.19 and 0.08 ng/ml, respectively. The precision investigation indicated that the intraassay precision values all were below 10% and that the interassay precision values ranged from 4.89 to 19.12%. In addition, the developed ELISA showed a good linear correlation (r(2)=0.9962) to gas chromatography within the analyte's concentration range of 0.1 to 16 ng/ml. When applied to the fortified samples (parathion adding level: 5-15 microg/kg), the developed ELISA presented mean recoveries of 127.46, 122.52, 91.92, 124.01, 129.72, 99.37, and 87.17% for tomato, cucumber, banana, apple, orange, pear, and sugarcane, respectively. Results indicated that the established ELISA is a potential tool for parathion residue determination.

  18. How should a district general hospital immunology service screen for anti-nuclear antibodies? An ‘in-the-field’ audit

    PubMed Central

    Hira-Kazal, R; Shea-Simonds, P; Peacock, J L; Maher, J

    2015-01-01

    Anti-nuclear antibody (ANA) testing assists in the diagnosis of several immune-mediated disorders. The gold standard method for detection of these antibodies is by indirect immunofluorescence testing on human epidermoid laryngeal carcinoma (HEp-2) cells. However, many laboratories test for these antibodies using solid-phase assays such as enzyme-linked immunosorbent assay (ELISA), which allows for higher throughput testing at reduced cost. In this study, we have audited the performance of a previously established ELISA assay to screen for ANA, making comparison with the gold standard HEp-2 immunofluorescence test. A prospective and unselected sample of 89 consecutive ANA test requests by consultant rheumatologists were evaluated in parallel over a period of 10 months using both tests. ELISA and HEp-2 screening assays yielded 40 (45%) and 72 (81%) positive test results, respectively, demonstrating lack of concordance between test methods. Using standard and clinical samples, it was demonstrated that the ELISA method did not detect several ANA with nucleolar, homogeneous and speckled immunofluorescence patterns. None of these ELISANEG HEp-2POS ANA were reactive with a panel of six extractable nuclear antigens or with double-stranded DNA. Nonetheless, 13 of these samples (15%) originated from patients with recognized ANA-associated disease (n = 7) or Raynaud's phenomenon (n = 6). We conclude that ELISA screening may fail to detect clinically relevant ANA that lack defined specificity for antigen. PMID:25412573

  19. Enzyme-linked immunosorbent assay for total sennosides using anti-sennside A and anti-sennoside B monoclonal antibodies.

    PubMed

    Morinaga, Osamu; Uto, Takuhiro; Sakamoto, Seiichi; Tanaka, Hiroyuki; Shoyama, Yukihiro

    2009-01-01

    Total sennosides concentration is a very important factor when rhubarb and senna will be used as crude drugs. However, one-step analytical technique for total sennosides has not been reported except HPLC. An enzyme-linked immunosorbent assay (ELISA) for total sennosides concentration by using the combination of anti-sennoside A (SA) and anti-sennoside B (SB) monoclonal antibodies (MAbs) in a single assay has been investigated. Total sennosides concentration in rhubarb and senna samples determined by newly developed assay system showed good agreement with those analyzed by ELISA using anti-SA MAb and anti-SB MAb, respectively.

  20. Validation of an Anaplasma marginale cELISA for use in the diagnosis of A. ovis infections in domestic sheep and Anaplasma spp. in wild ungulates.

    PubMed

    Scoles, Glen A; Goff, Will L; Lysyk, Timothy J; Lewis, Gregory S; Knowles, Donald P

    2008-07-27

    A commercially available (cELISA) kit for diagnosing Anaplasma marginale infection in cattle was validated for diagnosing A ovis infection in sheep using the bovine serum controls as supplied by the manufacturer (BcELISA) and sheep serum controls from pathogen-free sheep (OcELISA). True positives were identified using two previously established assays, a nested PCR (nPCR) test and an indirect immunofluorescent assay (IFA). The BcELISA was also applied to sera from various species of wild ruminants, comparing the results with the IFA. Receiver operating characteristic (ROC) analysis indicated that the predicted threshold inhibition for the BcELISA was 19.2. The sensitivity for the BcELISA was 98.2% and the specificity was 96.3%. The predicted threshold inhibition decreased to 14.3 for the OcELISA; the sensitivity was 96.5% and the specificity was 98.1%. There was >/=90% concordance between IFA and nPCR, as well as between the BcELISA at 19% inhibition cutoff and either IFA or PCR. Concordance between the cELISA and IFA using sera from elk, mule deer, bighorn sheep, pronghorn antelope, and black-tailed deer ranged from 64% to 100%. This commercially available cELISA test kit can be used very effectively to test domestic sheep for infection with A. ovis using the kit-supplied controls (i.e. the BcELISA) and a 19% inhibition cutoff; the kit may also be useful for detecting intra-erythrocytic Anaplasma infections in wild ruminants.

  1. Comparative evaluation of non-structural protein-antibody detecting ELISAs for foot-and-mouth disease sero-surveillance under intensive vaccination.

    PubMed

    Sharma, Gaurav Kumar; Mohapatra, Jajati Keshari; Mahajan, Sonalika; Matura, Rakesh; Subramaniam, Saravanan; Pattnaik, Bramhadev

    2014-10-01

    Foot-and-mouth disease is a highly infectious and contagious disease of livestock animals with transboundary and economical importance. Animals in the endemic settings are regularly vaccinated in addition to intensive surveillance for control of the disease. Under intensive vaccination, detection of infected animals among the vaccinated population is essential to monitor the infection and to track down the virus movement. Sero-surveillance and retrospective disease diagnosis is performed primarily by detecting antibodies against non-structural proteins (NSPs) of FMD virus which are usually absent in the inactivated vaccine formulations. The study was conducted with an objective to compare simultaneously performance of six NSP ELISAs in detecting infected animals in the areas covered under intensive vaccination, and to assess their fit-for-purpose attribute for sero-surveillance of FMD in India. A panel of bovine serum samples consisting of samples collected from infected with FMDV, vaccinated and naive animals were constituted. In addition, samples collected at random from areas having varied FMD situation and vaccination coverage were tested simultaneously by the six NSP ELISAs to compare their performances. The four indigenous assays showed varying degrees of correlation with the two commercial kits. The study validated that, in all the groups of samples, the indigenous assays were equally sensitive and specific as the two commercial kits. Among all the six assays, PrioCheck and in-house 3ABC I-ELISAs showed maximum sensitivity for detection of infected animals, whereas 3AB3 I-ELISA and 3ABC C-ELISA showed maximum specificity. The study concluded that the in-house available assays are equally capable as the commercially available kits for differentiation of infected animals under intensive vaccination and identifies the 3AB3 I-ELISA with optimum sensitivity and specificity for the purpose of sero-surveillance in India. Copyright © 2014 Elsevier B.V. All rights reserved.

  2. Assessing the cleanliness of surfaces: Innovative molecular approaches vs. standard spore assays

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cooper, M.; Duc, M.T. La; Probst, A.

    2011-04-01

    A bacterial spore assay and a molecular DNA microarray method were compared for their ability to assess relative cleanliness in the context of bacterial abundance and diversity on spacecraft surfaces. Colony counts derived from the NASA standard spore assay were extremely low for spacecraft surfaces. However, the PhyloChip generation 3 (G3) DNA microarray resolved the genetic signatures of a highly diverse suite of microorganisms in the very same sample set. Samples completely devoid of cultivable spores were shown to harbor the DNA of more than 100 distinct microbial phylotypes. Furthermore, samples with higher numbers of cultivable spores did not necessarilymore » give rise to a greater microbial diversity upon analysis with the DNA microarray. The findings of this study clearly demonstrated that there is not a statistically significant correlation between the cultivable spore counts obtained from a sample and the degree of bacterial diversity present. Based on these results, it can be stated that validated state-of-the-art molecular techniques, such as DNA microarrays, can be utilized in parallel with classical culture-based methods to further describe the cleanliness of spacecraft surfaces.« less

  3. Evaluation of a recombinant LigB protein of Leptospira interrogans serovar Canicola in an enzyme-linked immunosorbent assay for the serodiagnosis of bovine leptospirosis.

    PubMed

    Sankar, Surya; Harshan, Hiron M; Somarajan, S R; Srivastava, S K

    2010-06-01

    A recombinant leptospiral lipoprotein, LigB, was evaluated for use in the diagnosis of bovine leptospirosis by enzyme-linked immunosorbent assay (rLigB IgG ELISA). The standard reference test (Microscopic agglutination test, MAT) of 200 serum samples from cattle suspected of leptospirosis showed that 95 (47.5%) samples had positive agglutination titres, which ranged from 100 to 1600. In rLigB IgG ELISA, 49% of the samples were positive. Sensitivity of IgG ELISA for 95 bovine sera, which had MAT titres of greater than or equal to 100, were 100%. ELISA showed a specificity of 97.1% with 105 bovine sera, which were negative at a 1:50 dilution in MAT for Leptospira interrogans serovars. The results of ELISA and MAT correspond very good. When analytical specificity of IgG ELISA was evaluated using bovine serum samples from animals showing the serum antibodies to other pathogens, no cross-reaction was observed. Thus the recombinant LigB IgG ELISA can be used instead of the MAT as an aid to the diagnosis of bovine leptospirosis. Copyright 2009. Published by Elsevier India Pvt Ltd.

  4. Development of an enzyme-linked immunosorbent assay (ELISA) for residue analysis of the fungicide azoxystrobin in agricultural products.

    PubMed

    Kondo, Mika; Tsuzuki, Kazuyuki; Hamada, Hiroshi; Yamaguchi Murakami, Yukie; Uchigashima, Mikiko; Saka, Machiko; Watanabe, Eiki; Iwasa, Seiji; Narita, Hiroshi; Miyake, Shiro

    2012-02-01

    A direct competitive enzyme-linked immunosorbent assay (dc-ELISA) was developed for residue analysis of azoxystrobin in garden crops, for which the maximum residue limits (MRLs) are 0.5-50 mg/kg in Japan. For hapten synthesis, an ethyl carboxyl group was introduced to the 4-position of the 2-cyanophenoxy group in azoxystrobin, and its cyano group was changed to a methyl group. An anti-azoxystrobin monoclonal antibody was prepared from mice immunized with hapten-keyhole limpet hemocyanin conjugate. The dc-ELISA using prepared antibody showed 50-250-fold higher sensitivity compared to the MRLs. The working range of the dc-ELISA was 10-200 ng/mL. The dc-ELISA showed high specificity to azoxystrobin. When methanol extracts from nine kinds of garden crops spiked with azoxystrobin ranging near the MRLs were analyzed, the determined results by the dc-ELISA agreed well with the results of their controls. In addition, azoxystrobin spiked in garden crops homogenates was satisfactorily extracted by methanol solution and easily analyzed. The recovery rate of dc-ELISA was 96-109% and correlated well with the results obtained by HPLC analysis.

  5. Coupling solid-phase extraction and enzyme-linked immunosorbent assay for ultratrace determination of herbicides in pristine water

    USGS Publications Warehouse

    Aga, D.S.; Thurman, E.M.

    1993-01-01

    Solid-phase extraction (SPE) and enzyme-linked immunosorbent assay (ELISA) were coupled for automated trace analysis of pristine water samples containing 2-chloro-4-ethylamino-6-isopropylamine-s-triazine (atrazine) and 2-chloro-2???,6???-diethyl-N-(methoxymethyl)acetanilide (alachlor). The isolation of the two herbicides on a C18-resin involved the selection of an elution solvent that both removes interfering substances and is compatible with ELISA. Ethyl acetate was selected as the elution solvent followed by a solvent exchange with methanol/water (20/80, % v/v). The SPE-ELISA method has a detection limit of 5.0 ng/L (5 ppt), >90% recovery, and a relative standard deviation of ??10%. The performance of a microtiter plate-based ELISA and a magnetic particle-based ELISA coupled to SPE was also evaluated. Although the sensitivity of the two ELISA methods was comparable, the precision using magnetic particles was improved considerably (??10% versus ??20%) because of the faster reaction kinetics provided by the magnetic particles. Finally, SPE-ELISA and isotope dilution gas chromatography/ mass spectrometry correlated well (correlation coefficient of 0.96) for lake-water samples. The SPE-ELISA method is simple and may have broader applications for the inexpensive automated analysis of other contaminants in water at trace levels.

  6. [Shellfish monitoring system for paralytic shellfish toxins using enzyme-linked immunosorbent assay].

    PubMed

    Shinozaki, Takashi; Watanabe, Ryuichi; Kawatsu, Kentaro; Sakurada, Kiyonari; Takahi, Shinya; Ueno, Ken-ichi; Matsushima, Ryoji; Suzuki, Toshiyuki

    2013-01-01

    We investigated the applicability of enzyme-linked immunosorbent assay (PSP-ELISA) using a monoclonal antibody against paralytic shellfish toxins (PST) for screening oysters collected at several coastal areas in Kumamoto prefecture, Japan. Oysters collected between 2007 and 2010 were analyzed by PSP-ELISA. As an alternative calibrant, a naturally contaminated oyster extract was used to quantify toxins in the oyster samples. The toxicity of the calibrant oyster extract determined by the official testing method, mouse bioassay (MBA), was 4 MU/g. Oyster samples collected over 3 years showed a similar toxin profile to the alternative standard, resulting in good agreement between the PSP-ELISA and the MBA. The PSP-ELISA method was better than the MBA in terms of sensitivity, indicating that it may be useful for earlier warning of contamination of oysters by PST in the distinct coastal areas. To use the PSP-ELISA as a screening method prior to MBA, we finally set a screening level at 2 MU/g PSP-ELISA for oyster monitoring in Kumamoto prefecture. We confirmed that there were on samples exceeding the quarantine level (4 MU/g) in MBA among samples quantified as below the screening level by the PSP-ELISA. It was concluded that the use of PSP-ELISA could reduce the numbers of animals needed for MBA testing.

  7. Penicillinase-based enzyme-linked immunosorbent assay for the detection of plant viruses.

    PubMed

    Sudarshana, M R; Reddy, D V

    1989-10-01

    A penicillinase (PNC)-based, enzyme-linked immunosorbent assay (ELISA) was standardized to detect maize mosaic virus (MMV) in sorghum leaf extracts, peanut mottle virus (PMV) in pea leaf extracts, and tomato spotted wilt virus (TSWV) in peanut leaf extracts. Rabbit Fc-specific antibodies were conjugated with PNC by a single step glutaraldehyde bridge. Among several indicators tested, bromothymol blue (BTB) was found suitable for measuring PNC activity under simulated conditions. Two reagents, starch-iodine complex (SIC) and a mixed pH indicator, containing bromocresol purple and BTB (2:1) used earlier for the PNC-based ELISA, were compared with BTB for utilization in the PNC-based ELISA. SIC gave a slightly higher virus titre than BTB or the mixed pH indicator, but it often gave nonspecific reactions. Sodium or potassium salts of penicillin-G at 0.5-1.0 mg/ml and BTB at 0.2 mg/ml were found to be suitable as substrate-indicator mixture for PNC-based ELISA. The sensitivity of the PNC system was comparable to those of the alkaline phosphatase (ALP) and horseradish peroxidase (HRP) systems in detecting MMV, PMV, and TSWV. The PNC conjugate could be used at a greater dilution than those of the ALP and HRP conjugates and the BTB substrate mixture was stable for at least 3 weeks at 4 degrees C. Penicillin is readily available in developing countries, and at a substantially lower cost than p-nitrophenyl phosphate, the commonly used substrate for ALP in the plate ELISA. Thus the PNC-based ELISA provides a less expensive means for assaying plant viruses by ELISA.

  8. Comparison of three multiplex cytokine analysis systems: Luminex, SearchLight and FAST Quant.

    PubMed

    Lash, Gendie E; Scaife, Paula J; Innes, Barbara A; Otun, Harry A; Robson, Steven C; Searle, Roger F; Bulmer, Judith N

    2006-02-20

    Multiplex cytokine analysis technologies have become readily available in the last five years. Two main formats exist: multiplex sandwich ELISA and bead based assays. While these have each been compared to individual ELISAs, there has been no direct comparison between the two formats. We report here the comparison of two multiplex sandwich ELISA procedures (FAST Quant and SearchLight) and a bead based assay (UpState Luminex). All three kits differed from each other for different analytes and there was no clear pattern of one system giving systematically different results than another for any analyte studied. We suggest that each system has merits and several factors including range of analytes available, prospect of development of new analytes, dynamic range of the assay, sensitivity of the assay, cost of equipment, cost of consumables, ease of use and ease of data analysis need to be considered when choosing a system for use. We also suggest that results obtained from different systems cannot be combined.

  9. 77 FR 7109 - Establishment of User Fees for Filovirus Testing of Nonhuman Primate Liver Samples

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-10

    ... assay (ELISA) or other appropriate methodology. Each specimen will be held for six months. After six... loss of the only commercially available antigen-detection ELISA filovirus testing facility. Currently... current methodology (ELISA) used to test NHP liver samples. This cost determines the amount of the user...

  10. DARPA Antibody Technology Program Standardized Test Bed for Antibody Characterization: Characterization of an MS2 Human IgG Antibody Produced by AnaptysBio, Inc.

    DTIC Science & Technology

    2016-02-01

    Enzyme-linked immunosorbent assay ( ELISA ) Quality Testing MS2 coat protein (MS2CP) 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF... ELISA ................................................................................................................4 2.8 SPR Method...3.5 ELISA Results .................................................................................................11 3.6 SPR Results

  11. Development and evaluation of flow through assay for detection of antibodies against porcine cysticercosis.

    PubMed

    Sreedevi, C; Hafeez, Md; Subramanyam, K V; Anand Kumar, P; Chengalva Rayulu, V

    2011-04-01

    A flow through assay (FTA) was developed on cellulose acetate membrane for the serodiagnosis of porcine cysticercosis using cyst fluid (CFA) and whole cyst antigens (WCA) of Taenia solium metacestode. The assay consisted of antigen of T. solium metacestode coated onto membrane, mounted on a flow-through test device to provide assay capture matrix. The optimum concentration of coating antigen was 250 ng. The protein A colloidal gold conjugate served as antigen-antibody detecting reagent. A total of 225 serum samples were tested using two antigens. Results were better with CFA (96.0% sensitivity; 96.0% specificity) compared to WCA (92.0% sensitivity; 96.0% specificity). The test was also compared with enzyme-linked immunosorbent assay. The ELISA showed 96 per cent sensitivity with both the antigens whereas; the specificity was 96 and 92 per cent with CFA and WCA respectively. The sensitivity and specificity of flow through assay agrees closely with those of the ELISA. The cross-reaction was observed in one out of eight hydatidosis positive pigs (12.5%) with CFA by both the assays. The highest diagnostic accuracy (96%) was obtained with CFA-FTA and CFA-ELISA. For its high sensitivity and sporadic cross-reactions, CFA-FTA appears to be suitable for practical use at field level without instrumentation.

  12. Development of an Indirect ELISA for Serological Diagnosis of Bovine herpesvirus 5

    PubMed Central

    Campos, Fabrício S.; da Rosa, Matheus C.; Finger, Paula F.; de Oliveira, Patricia D.; Conceição, Fabricio R.; Fischer, Geferson; Roehe, Paulo M.; Leite, Fábio P. L.

    2016-01-01

    Bovine herpesviruses 1 and 5 (BoHV-1 and BoHV-5) are economically important pathogens, associated with a variety of clinical syndromes, including respiratory and genital disease, reproductive failure and meningoencephalitis. The standard serological assay to diagnose BoHV-1 and BoHV-5 infections is the virus neutralization test (VNT), a time consuming procedure that requires manipulation of infectious virus. In the present study a highly sensitive and specific single dilution indirect ELISA was developed using recombinant glycoprotein D from BoHV-5 as antigen (rgD5ELISA). Bovine serum samples (n = 450) were screened by VNT against BoHV-5a and by rgD5ELISA. Compared with the VNT, the rgD5ELISA demonstrated accuracy of 99.8%, with 100% sensitivity, 96.7% specificity and coefficient of agreement between the tests of 0.954. The rgD5ELISA described here shows excellent agreement with the VNT and is shown to be a simple, convenient, specific and highly sensitive virus-free assay for detection of serum antibodies to BoHV-5. PMID:26866923

  13. Comparative evaluation of three different ELISA assays and HPLC-ESI-ITMS/MS for the analysis of Nε-carboxymethyl lysine in food samples.

    PubMed

    Gómez-Ojeda, Armando; Jaramillo-Ortíz, Sarahi; Wrobel, Katarzyna; Wrobel, Kazimierz; Barbosa-Sabanero, Gloria; Luevano-Contreras, Claudia; de la Maza, Maria Pia; Uribarri, Jaime; Del Castillo, Ma Dolores; Garay-Sevilla, Ma Eugenia

    2018-03-15

    N ε -carboxymethyl-lysine (CML) is measured in food, but there is a controversy concerning the most convenient yet reliable method(s) for this task. This work compares three different ELISA assays and HPLC-ESI-ITMS/MS for the analysis of CML in several food items. The four methods showed the same decreasing order of CML concentration: beef, bacon>chicken > fish>dairy products>grain products>fruits/vegetables. HPLC-ESI-ITMS/MS results highly correlated with those obtained by ELISA performed with monoclonal CML-antibody (β=0.98, p<0.0001) whereas My Bio Source® kit results were not correlated with those provided by Lamider®. Small differences of CML concentrations in food items prepared by different culinary treatment were clearly distinguished by HPLC-ESI-ITMS/MS, but could not always be detected by ELISA. This work demonstrates a reasonable relationship between CM determined by ELISA and HPLC-ESI-ITMS/MS and therefore supports the implementation of ELISA in food CML/AGEs screening. Copyright © 2017. Published by Elsevier Ltd.

  14. Development of enzyme linked immunosorbent assay (ELISA) for the detection of root-knot nematode Meloidogyne incognita.

    PubMed

    Kapur-Ghai, J; Kaur, M; Goel, P

    2014-09-01

    Root-knot nematodes (Meloidogyne incognita) are obligate, sedentary plant endoparasites that are extremely polyphagous in nature and cause severe economic losses in agriculture. Hence, it is essential to control the parasite at an early stage. For any control strategy to be effective, an early and accurate diagnosis is of paramount importance. Immunoassays have the inherent advantages of sensitivity and specificity; have the potential to identify and quantify these plant-parasitic nematodes. Hence, in the present studies, enzyme-linked immunosorbent assay (ELISA) has been developed for the detection of M.incognita antigens. First an indirect ELISA was developed for detection and titration of anti-M.incognita antibodies. Results indicated as high as 320 K titre of the antisera. Finally competitive inhibition ELISA was developed employing these anti-M.incognita antibodies for detection of M.incognita antigens. Sensitivity of ELISA was 10 fg. Competitive inhibition ELISA developed in the present studies has the potential of being used as an easy, rapid, specific and sensitive diagnostic tool for the detection of M.incognita infection.

  15. Nucleoprotein-based indirect enzyme-linked immunosorbent assay (indirect ELISA) for detecting antibodies specific to Ebola virus and Marbug virus.

    PubMed

    Huang, Yi; Zhu, Youjie; Yang, Mengshi; Zhang, Zhenqing; Song, Donglin; Yuan, Zhiming

    2014-12-01

    Full-length nucleoproteins from Ebola and Marburg viruses were expressed as His-tagged recombinant proteins in Escherichia coli and nucleoprotein-based enzyme-linked immunosorbent assays (ELISAs) were established for the detection of antibodies specific to Ebola and Marburg viruses. The ELISAs were evaluated by testing antisera collected from rabbit immunized with Ebola and Marburg virus nucleoproteins. Although little cross-reactivity of antibodies was observed in anti-Ebola virus nucleoprotein rabbit antisera, the highest reactions to immunoglobulin G (IgG) were uniformly detected against the nucleoprotein antigens of homologous viruses. We further evaluated the ELISA's ability to detect antibodies to Ebola and Marburg viruses using human sera samples collected from individuals passing through the Guangdong port of entry. With a threshold set at the mean plus three standard deviations of average optical densities of sera tested, the ELISA systems using these two recombinant nucleoproteins have good sensitivity and specificity. These results demonstrate the usefulness of ELISA for diagnostics as well as ecological and serosurvey studies of Ebola and Marburg virus infection.

  16. Development of an Antigen Capture Enzyme-Linked Immunosorbent Assay for Virus Detection Based on Porcine Epidemic Diarrhea Virus Monoclonal Antibodies

    PubMed Central

    Wang, Zanyu; Jiyuan, Yin; Su, Chen; Xinyuan, Qiao

    2015-01-01

    Abstract Porcine epidemic diarrhea virus (PEDV), a coronavirus, can cause acute diarrhea and dehydration in pigs. In the current study, two positive monoclonal cell lines (5D7 and 3H4) specific for PEDV were established, and the immunoreactivity of the monoclonal antibodies was confirmed by immunofluorescence and dot-immunobinding assays. A method, termed antigen capture enzyme-linked immunosorbent assay (AC-ELISA), which used the monoclonal antibody 5D7 as the detecting antibody and rabbit antiserum of PEDV protein S as the capture antibody, was developed. Compared with the reverse transcription polymerase chain reaction method of detecting PEDV in fecal samples, AC-ELISA showed similar sensitivity and specificity. These results suggested that AC-ELISA would be useful for the diagnosis and epidemiological studies of PEDV. PMID:25658793

  17. The Effect of Different Methods of Fermentation on the Detection of Milk Protein Residues in Retail Cheese by Enzyme-Linked Immunosorbent Assay (ELISA).

    PubMed

    Ivens, Katherine O; Baumert, Joseph L; Hutkins, Robert L; Taylor, Steve L

    2017-11-01

    Milk and milk products are among the most important allergenic food ingredients, both in the United States and throughout the world; cheeses are among the most important of these milk products. Milk contains several major antigenic proteins, each with differing susceptibilities to proteolytic enzymes. The extent of proteolysis in cheese varies as a result of conditions during manufacture and ripening. Proteolysis has the potential to degrade antigenic and allergenic epitopes that are important for residue detection and elicitation of allergic reactions. Commercial enzyme-linked immunosorbent assays (ELISAs) are not currently validated for use in detecting residues in hydrolyzed or fermented food products. Eighteen retail cheeses produced using 5 different styles of fermentation were investigated for detectable milk protein residues with 4 commercial ELISA kits. Mozzarella, Swiss, Blue, Limburger, and Brie cheeses were assessed. The Neogen Veratox® Casein and Neogen Veratox® Total Milk kits were capable of detecting milk residues in most cheeses evaluated, including blue-veined cheeses that exhibit extensive proteolysis. The other 2 ELISA kits evaluated, r-Biopharm® Fast Casein and ELISA Systems™ Casein, can detect milk residues in cheeses other than blue-veined varieties. ELISA results cannot be quantitatively compared among kits. The quantitative reliability of ELISA results in detection of cheese residues is questionable, but some methods are sufficiently robust to use as a semi-quantitative indication of proper allergen control for the validation of cleaning programs in industry settings. Many commercially available enzyme-linked immunosorbent assays (ELISAs) are not validated for detection of allergenic residues in fermented or hydrolyzed products. This research seeks to determine if commercial milk ELISAs can detect milk residues in varieties of cheese that have undergone different styles of fermentation and different degrees of proteolysis. Only certain milk ELISA kits are capable of detecting residues in all varieties of cheese. However, commercial milk ELISA kits are capable of semiquantitative detection of cheese residues in foods, or in industry settings for the validation of allergen cleaning programs. © 2017 Institute of Food Technologists®.

  18. Development of a rapid microarray-based DNA subtyping assay for the alleles of Shiga toxins 1 and 2 of Escherichia coli.

    PubMed

    Geue, Lutz; Stieber, Bettina; Monecke, Stefan; Engelmann, Ines; Gunzer, Florian; Slickers, Peter; Braun, Sascha D; Ehricht, Ralf

    2014-08-01

    In this study, we developed a new rapid, economic, and automated microarray-based genotyping test for the standardized subtyping of Shiga toxins 1 and 2 of Escherichia coli. The microarrays from Alere Technologies can be used in two different formats, the ArrayTube and the ArrayStrip (which enables high-throughput testing in a 96-well format). One microarray chip harbors all the gene sequences necessary to distinguish between all Stx subtypes, facilitating the identification of single and multiple subtypes within a single isolate in one experiment. Specific software was developed to automatically analyze all data obtained from the microarray. The assay was validated with 21 Shiga toxin-producing E. coli (STEC) reference strains that were previously tested by the complete set of conventional subtyping PCRs. The microarray results showed 100% concordance with the PCR results. Essentially identical results were detected when the standard DNA extraction method was replaced by a time-saving heat lysis protocol. For further validation of the microarray, we identified the Stx subtypes or combinations of the subtypes in 446 STEC field isolates of human and animal origin. In summary, this oligonucleotide array represents an excellent diagnostic tool that provides some advantages over standard PCR-based subtyping. The number of the spotted probes on the microarrays can be increased by additional probes, such as for novel alleles, species markers, or resistance genes, should the need arise. Copyright © 2014, American Society for Microbiology. All Rights Reserved.

  19. Hydrogel droplet microarrays with trapped antibody-functionalized beads for multiplexed protein analysis.

    PubMed

    Li, Huiyan; Leulmi, Rym Feriel; Juncker, David

    2011-02-07

    Antibody microarrays are a powerful tool for rapid, multiplexed profiling of proteins. 3D microarray substrates have been developed to improve binding capacity, assay sensitivity, and mass transport, however, they often rely on photopolymers which are difficult to manufacture and have a small pore size that limits mass transport and demands long incubation time. Here, we present a novel 3D antibody microarray format based on the entrapment of antibody-coated microbeads within alginate droplets that were spotted onto a glass slide using an inkjet. Owing to the low concentration of alginate used, the gels were highly porous to proteins, and together with the 3D architecture helped enhance mass transport during the assays. The spotting parameters were optimized for the attachment of the alginate to the substrate. Beads with 0.2 µm, 0.5 µm and 1 µm diameter were tested and 1 µm beads were selected based on their superior retention within the hydrogel. The beads were found to be distributed within the entire volume of the gel droplet using confocal microscopy. The assay time and the concentration of beads in the gels were investigated for maximal binding signal using one-step immunoassays. As a proof of concept, six proteins including cytokines (TNFα, IL-8 and MIP/CCL4), breast cancer biomarkers (CEA and HER2) and one cancer-related protein (ENG) were profiled in multiplex using sandwich assays down to pg mL(-1) concentrations with 1 h incubation without agitation in both buffer solutions and 10% serum. These results illustrate the potential of beads-in-gel microarrays for highly sensitive and multiplexed protein analysis.

  20. Enzyme-linked immunosorbent assay for Escherichia coli heat-stable enterotoxin type II.

    PubMed Central

    Handl, C; Rönnberg, B; Nilsson, B; Olsson, E; Jonsson, H; Flock, J I

    1988-01-01

    The gene for Escherichia coli heat-stable enterotoxin type II (STII) was fused to the genes for protein A from Staphylococcus aureus and beta-galactosidase in two different expression systems. Antibodies raised in rabbits against the protein A-STII fusion protein recognized the beta-galactosidase-STII fusion protein. The latter fusion protein was used as the immobilized antigen in an enzyme-linked immunosorbent assay (ELISA) for detection of STII. The correlation between the results of the ELISA and the intestinal loop test in piglets was 95%, suggesting that the ELISA can be used to reliably detect STII. Images PMID:3049659

  1. Interpreting dual ELISA and qPCR data for bacterial kidney disease of salmonids.

    PubMed

    Nance, Shelly L; Riederer, Michael; Zubkowski, Tyler; Trudel, Marc; Rhodes, Linda D

    2010-09-02

    Although there are a variety of methods available for the detection of Renibacterium salmoninarum, the causative agent of bacterial kidney disease in salmon and trout, the enzyme-linked immunosorbent assay (ELISA) is probably the most widely used method. However, ELISA measures bacterial antigen, which does not necessarily reflect the number of cells present. We hypothesized that dual analysis of kidney tissue by ELISA and a quantitative real-time polymerase chain reaction assay (qPCR) would provide complementary information about antigen level and the number of bacterial genomes. We found that DNA extracted from the insoluble fraction of the ELISA tissue preparation produced the same qPCR result as DNA extracted directly from frozen tissue, permitting true dual analysis of the same tissue sample. We examined kidney tissue in this manner from individual free-ranging juvenile Chinook salmon and antibiotic-treated captive subadult Chinook salmon and observed 3 different patterns of results. Among the majority of fish, there was a strong correlation between the ELISA value and the qPCR value. However, subsets of fish exhibited either low ELISA values with elevated qPCR values or higher ELISA values with very low qPCR values. These observations suggest a conceptual model that allows inferences about the state of infection of individual fish based on dual ELISA/qPCR results. Although this model requires further assessment through experimental infections and treatments, it may have utility in broodstock selection programs that currently apply egg-culling practices based on ELISA alone.

  2. Development of an enzyme-linked immunosorbent assay for residue analysis of the insecticide emamectin benzoate in agricultural products.

    PubMed

    Kondo, Mika; Yamashita, Hiroshi; Uchigashima, Mikiko; Kono, Takeshi; Takemoto, Toshihide; Fujita, Masahiro; Saka, Machiko; Iwasa, Seiji; Ito, Shigekazu; Miyake, Shiro

    2009-01-28

    A direct competitive enzyme-linked immunosorbent assay (dc-ELISA) for the analysis of emamectin residues in agricultural products was developed using a prepared mouse monoclonal antibody. The working range was 0.3-3.0 ng/mL, and the 50% inhibition concentration (IC(50)) was 1.0 ng/mL. The assay was sufficiently sensitive for analysis of the maximum residue limits in agricultural products in Japan (>0.1 microg/g). Emamectin residues contain the following metabolites: the 4''-epi-amino analogue, the 4''-epi-(N-formyl)amino analogue, the 4''-epi-(N-formyl-N-methyl)amino analogue, and the 8,9-Z isomer. The dc-ELISA reacted with these compounds at ratios of 113, 55, 38, and 9.1% of the IC(50) value of emamectin benzoate. Seven kinds of vegetables were spiked with emamectin benzoate at concentrations of 15-300 ng/g, and the recoveries were 91-117% in the dc-ELISA. The dc-ELISA results agreed reasonably well with results obtained by liquid chromatography-tandem mass spectrometry (LC-MS/MS) using spiked samples and actual (incurred) samples. The results indicate that the dc-ELISA was useful for the analysis of emamectin benzoate residues in agricultural products.

  3. Development of an epitope-blocking-enzyme-linked immunosorbent assay to differentiate between animals infected with and vaccinated against foot-and-mouth disease virus.

    PubMed

    Oem, Jae Ku; Chang, Byung Sik; Joo, Hoo Don; Yang, Mi Young; Kim, Gwang Jae; Park, Jee Yong; Ko, Young Joon; Kim, Yong Ju; Park, Jong Hyeon; Joo, Yi Seok

    2007-06-01

    An epitope-blocking ELISA (EB-ELISA) was developed to distinguish animals infected with foot-and-mouth-disease (FMDV) from those immunized with commercial vaccines. The assay used monoclonal antibodies to target the 3B core repeat motif (QKPLK) and purified recombinant 3AB proteins from the major B cell line epitopes of FMDV. Sera from uninfected and regularly vaccinated cattle, pigs, goats, and sheep (raised in FMDV free areas) were screened to evaluate the specificity of the EB-ELISA. The specificity scores of the assays were 99.8-100% and 100%, respectively. Reference sera from cattle, pigs, goats, and sheep experimentally infected with FMDV tested positive, with only a single exception. Antibodies formed in response to FMDV 3B appeared 1 week after infection and persisted at high levels for more than 8 weeks within the sera collected from serial bleeding of animals infected with FMDV O/SKR/2000. The EB-ELISA was used to differentiate between farms vaccinated against and those infected with FMDV (FMDV Asia serotype) during the 2005 epidemic in Mongolia by detecting antibodies against the FMDV Asia serotype in outbreak farms. This EB-ELISA method shows promise as an effective tool for FMDV control and eradication.

  4. [Trypanosoma cruzi in triatomines from Nuevo Leon, Mexico].

    PubMed

    Molina-Garza, Zinnia Judith; Rosales-Encina, José Luis; Galaviz-Silva, Lucio; Molina-Garza, Daniel

    2007-01-01

    To determine the prevalence of Trypanosoma cruzi in triatomines from Nuevo León using the standardization of an improved enzyme-linked immunosorbent assay test. From July to September 2005, 52 triatomines were captured in General Terán, a municipality located in Nuevo León. They were analyzed using optical microscopy (OM) and a polymerase chain reaction (PCR), as standards of reference, to develop a technique for detecting the parasite using enzyme-linked immunosorbent assay (ELISA). Using OM and PCR, 31 triatomines were found to be positive and 21 negative. Using ELISA, 27 samples were identified as positive and 25 negative (specificity 100%, sensitivity 87%, negative predictive value 84%, and positive predictive value 100%). The prevalence of infected triatomines was 59.61% with OM and PCR, and 51.92% with ELISA. Our data confirm that the ELISA assay in triatomines is a fast, reliable and useful tool. Since it was possible to simultaneously analyze a large number of samples with high sensibility and specificity values, the ELISA test proves to be useful for new epidemiologic studies having a high number of vectors. It is also less expensive than PCR. It is therefore recommended for epidemiological and preventive surveillance programs as a first screening test before conducting a confirmatory test using PCR.

  5. Development of antibodies to protective antigen and lethal factor components of anthrax toxin in humans and guinea pigs and their relevance to protective immunity.

    PubMed Central

    Turnbull, P C; Broster, M G; Carman, J A; Manchee, R J; Melling, J

    1986-01-01

    A competitive inhibition enzyme-linked immunosorbent assay (ELISA) was developed to detect antibodies in serum to the protective antigen (PA) and lethal factor (LF) components of anthrax toxin. Current human vaccination schedules with an acellular vaccine induce predictable and lasting antibody titers to PA and, when present in the vaccine, to LF. Live spore vaccine administered to guinea pigs in a single dose conferred significantly better protection than the human vaccines (P less than 0.001), although they elicited significantly lower (P less than 0.0005) anti-PA and anti-LF titers at time of challenge with virulent Bacillus anthracis. Substantial anti-PA and anti-LF titers may not, therefore, indicate solid protective immunity against anthrax infection. The ELISA system was also shown to be capable of detecting anti-PA and anti-LF antibodies in the sera of individuals with histories of clinical anthrax. The advantage of ELISA over the Ouchterlony gel diffusion test and indirect microhemagglutination assay are demonstrated. There was a highly significant degree of correlation between ELISA and the indirect microhemagglutination assay (P less than 0.0005); but ELISA was markedly superior in terms of reproducibility, reliability, specificity, and simplicity in performance and stability of the bound antigen. PMID:3084381

  6. Proactive therapeutic drug monitoring of infliximab: a comparative study of a new point-of-care quantitative test with two established ELISA assays.

    PubMed

    Afonso, J; Lopes, S; Gonçalves, R; Caldeira, P; Lago, P; Tavares de Sousa, H; Ramos, J; Gonçalves, A R; Ministro, P; Rosa, I; Vieira, A I; Dias, C C; Magro, F

    2016-10-01

    Therapeutic drug monitoring is a powerful strategy known to improve the clinical outcomes and to optimise the healthcare resources in the treatment of autoimmune diseases. Currently, most of the methods commercially available for the quantification of infliximab (IFX) are ELISA-based, with a turnaround time of approximately 8 h, and delaying the target dosage adjustment to the following infusion. To validate the first point-of-care IFX quantification device available in the market - the Quantum Blue Infliximab assay (Buhlmann, Schonenbuch, Switzerland) - by comparing it with two well-established methods. The three methods were used to assay the IFX concentration of spiked samples and of the serum of 299 inflammatory bowel diseases (IBD) patients undergoing IFX therapy. The point-of-care assay had an average IFX recovery of 92%, being the most precise among the tested methods. The Intraclass Correlation Coefficients of the point-of-care IFX assay vs. the two ELISA-based established methods were 0.889 and 0.939. Moreover, the accuracy of the point-of-care IFX compared with each of the two reference methods was 77% and 83%, and the kappa statistics revealed a substantial agreement (0.648 and 0.738). The Quantum Blue IFX assay can successfully replace the commonly used ELISA-based IFX quantification kits. This point-of-care IFX assay is able to deliver the results within 15 min makes it ideal for an immediate target concentration adjusted dosing. Moreover, it is a user-friendly desktop device that does not require specific laboratory facilities or highly specialised personnel. © 2016 John Wiley & Sons Ltd.

  7. A highly rapid and simple competitive enzyme-linked immunosorbent assay for monitoring paralytic shellfish poisoning toxins in shellfish.

    PubMed

    Kawatsu, Kentaro; Kanki, Masashi; Harada, Tetsuya; Kumeda, Yuko

    2014-11-01

    Using a streptavidin-coated well plate, a biotin-labelled anti-gonyautoxin 2/3 monoclonal antibody GT-13A, and a decarbamoyl saxitoxin-peroxidase conjugate, a direct competitive enzyme-linked immunosorbent assay (PSP-ELISA) was developed for monitoring paralytic shellfish poisoning (PSP) toxins in shellfish. This assay is simple to perform and can be completed in approximately 20 min. The PSP-ELISA was compared to the mouse bioassay (MBA) for the detection of PSP toxins in shellfish samples (n=83) collected from the coast of Osaka Prefecture, Japan. When positive and negative results were indicated based on the regulatory limit for PSP toxins (4 mouse unit(MU)/g of shellfish meat), the PSP-ELISA results showed a sensitivity of 100% (25 of 25) and a specificity of 89.7% (52 of 58 samples) compared to the MBA results. These results suggest that the PSP-ELISA could be used as a rapid and simple screening method prior to the MBA. Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. Development and evaluation of antibody-capture immunoassays for detection of Lassa virus nucleoprotein-specific immunoglobulin M and G.

    PubMed

    Gabriel, Martin; Adomeh, Donatus I; Ehimuan, Jacqueline; Oyakhilome, Jennifer; Omomoh, Emmanuel O; Ighodalo, Yemisi; Olokor, Thomas; Bonney, Kofi; Pahlmann, Meike; Emmerich, Petra; Lelke, Michaela; Brunotte, Linda; Ölschläger, Stephan; Thomé-Bolduan, Corinna; Becker-Ziaja, Beate; Busch, Carola; Odia, Ikponmwosa; Ogbaini-Emovon, Ephraim; Okokhere, Peter O; Okogbenin, Sylvanus A; Akpede, George O; Schmitz, Herbert; Asogun, Danny A; Günther, Stephan

    2018-03-01

    The classical method for detection of Lassa virus-specific antibodies is the immunofluorescence assay (IFA) using virus-infected cells as antigen. However, IFA requires laboratories of biosafety level 4 for assay production and an experienced investigator to interpret the fluorescence signals. Therefore, we aimed to establish and evaluate enzyme-linked immunosorbent assays (ELISA) using recombinant Lassa virus nucleoprotein (NP) as antigen. The IgM ELISA is based on capturing IgM antibodies using anti-IgM, and the IgG ELISA is based on capturing IgG antibody-antigen complexes using rheumatoid factor or Fc gamma receptor CD32a. Analytical and clinical evaluation was performed with 880 sera from Lassa fever endemic (Nigeria) and non-endemic (Ghana and Germany) areas. Using the IFA as reference method, we observed 91.5-94.3% analytical accuracy of the ELISAs in detecting Lassa virus-specific antibodies. Evaluation of the ELISAs for diagnosis of Lassa fever on admission to hospital in an endemic area revealed a clinical sensitivity for the stand-alone IgM ELISA of 31% (95% CI 25-37) and for combined IgM/IgG detection of 26% (95% CI 21-32) compared to RT-PCR. The specificity of IgM and IgG ELISA was estimated at 96% (95% CI 93-98) and 100% (95% CI 99-100), respectively, in non-Lassa fever patients from non-endemic areas. In patients who seroconverted during follow-up, Lassa virus-specific IgM and IgG developed simultaneously rather than sequentially. Consistent with this finding, isolated IgM reactivity, i.e. IgM in the absence of IgG, had no diagnostic value. The ELISAs are not equivalent to RT-PCR for early diagnosis of Lassa fever; however, they are of value in diagnosing patients at later stage. The IgG ELISA may be useful for epidemiological studies and clinical trials due its high specificity, and the higher throughput rate and easier operation compared to IFA.

  9. Validation of an enzyme-linked immunosorbent assay developed for measuring cortisol concentration in human saliva and serum for its applicability to analyze cortisol in pig saliva.

    PubMed

    Thomsson, Ola; Ström-Holst, Bodil; Sjunnesson, Ylva; Bergqvist, Ann-Sofi

    2014-09-06

    The purpose of this study was to validate a commercially available enzyme-linked immunosorbent assay (ELISA) developed for measuring free cortisol in human saliva and total cortisol concentration in diluted human serum, for its applicability in measuring cortisol concentration in pig saliva. Collection of saliva is less stressful than e.g. blood sampling, and is a non-invasive method. Saliva was collected by allowing sows to chew on cotton swabs held by forceps. Thereafter, the swabs were centrifuged to retrieve the saliva. The ELISA was performed according to instructions provided by the manufacturer. To validate the ELISA, determination of the intra-assay coefficient of variation (CV), inter-assay CV, recovery, linearity and parallelism was performed. The intra-assay CV was below 10% and inter-assay CV below 15% for samples of high, medium and low cortisol concentrations. The mean recovery was 117% and the linearity and parallelism showed an r2-value of 0.994 and 0.993, respectively. For biological assessment of induced social stress, two saliva samples were collected in the morning from 6 primiparous and 21 multiparous sows. One sample was collected when the sows were individually housed in a farrowing pen and a second sample was collected when the sows were group housed. The primiparous sows had a significant higher cortisol concentration compared to the multiparous sows when group housed. The results obtained in this validation study indicate that the ELISA is suitable for measuring cortisol concentration in porcine saliva.

  10. A First Application of Enzyme-Linked Immunosorbent Assay for Screening Cyclodiene Insecticides in Ground Water

    USGS Publications Warehouse

    Dombrowski, T.R.; Thurman, E.M.; Mohrman, G.B.

    1996-01-01

    A commercially available enzyme-linked immunosorbent assay (ELISA) plate kit for screening of cyclodiene insecticides (aldrin, chlordane, dieldrin, endosulfan, endrin, and heptachlor) was evaluated for sensitivity, cross reactivity, and overall performance using groundwater samples from a contaminated site. Ground-water contaminants included several pesticide compounds and their manufacturing byproducts, as well as many other organic and inorganic compounds. Cross-reactivity studies were carried out for the cyclodiene compounds, and results were compared to those listed by the manufacturer. Data obtained were used to evaluate the sensitivity of the ELISA kit to the cyclodiene compounds in ground water samples with a contaminated matrix. The method quantitation limit for the ELISA kit was 15 ??g/L (as chlordane). Of the 56 ground-water samples analyzed using the ELISA plate kits, more than 85% showed cyclodiene insecticide contamination. The ELISA kit showed excellent potential as a screening tool for sites with suspected groundwater contamination by insecticides.

  11. Evaluation of an enzyme-linked immunosorbent assay (ELISA) for the serological diagnosis of sarcoptic mange in dogs.

    PubMed

    Lower, K S; Medleau, L M; Hnilica, K; Bigler, B

    2001-12-01

    Canine scabies is a challenging disease to diagnose because sarcoptic mites are hard to find on skin scrapings. The purpose of this study was to evaluate a serologic enzyme-linked immunosorbent assay (ELISA) as an aid in the diagnosis of canine scabies. In addition, serum samples were obtained post treatment to determine the duration and persistence of circulating scabies antibodies after resolution of natural infection. Nineteen dogs diagnosed with sarcoptic mange and 38 control dogs were tested. Sixteen scabies-infested dogs showed positive pretreatment ELISA results (84.2% sensitivity). Thirty-four control dogs showed negative ELISA results (89.5% specificity). In the 11 scabies dogs from which multiple post treatment serum samples were obtained, detectable antibodies were not present 1 month after treatment in four cases, but were present for 1-4.5 months post treatment in seven dogs. Our results suggest that this scabies ELISA test is useful in the diagnosis of canine scabies.

  12. Optimization and validation of indirect ELISA using truncated TssB protein for the serodiagnosis of glanders amongst equines.

    PubMed

    Singha, Harisankar; Malik, Praveen; Goyal, Sachin K; Khurana, Sandip K; Mukhopadhyay, Chiranjay; Eshwara, Vandana K; Singh, Raj K

    2014-01-01

    To express truncated TssB protein of Burkholderia mallei and to evaluate its diagnostic efficacy for serological detection of glanders among equines. In an attempt to develop recombinant protein based enzyme-linked immunosorbent assay (ELISA), N-terminal 200 amino acid sequences of B. mallei TssB protein-a type 6 secretory effector protein--were expressed in prokaryotic expression system. Diagnostic potential of recombinant TssB protein was evaluated in indirect ELISA using a panel of glanders positive (n = 49), negative (n = 30), and field serum samples (n = 1811). Cross-reactivity of the assay was assessed with equine disease control serum and human melioidosis positive serum. In comparison to CFT, diagnostic sensitivity and specificity of ELISA were 99.7% and 100%, respectively. The indirect ELISA method using the truncated TssB offered safer and more rapid and efficient means of serodiagnosis of glanders in equines. These data highlight the use of TssB as potential diagnostic antigen for serological diagnosis of glanders.

  13. Improvement of an enzyme immunosorbent assay for detecting antibodies against Dioctophyma renale.

    PubMed

    Pedrassani, Daniela; do Nascimento, Adjair Antonio; André, Marcos Rogério; Machado, Rosangela Zacarias

    2015-09-15

    An available enzyme-linked immunosorbent assay (ELISA) was studied for the detection of anti-Dioctophyma renale antibodies in the sera of dogs using, detection of parasite eggs in urine sediment as a reference test. ELISA uses a soluble antigenic preparation of esophagus of D. renale and the optimal dilutions of the antigen, serum and conjugate were determined by means of checker board titration, using positive (n=13) and negative (n=27) reference serum. The specificity and sensitivity of the ELISA were 93.8% and 92.3% respectively and the kappa index was good (0.76). These results suggest that ELISA described may prove to be an effective serological test for detecting dogs infected and exposed to this parasite mainly dogs that are not eliminating parasite eggs through their urine. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Antibody-capture enzyme-linked immunosorbent assays that use enzyme-labelled antigen for detection of virus-specific immunoglobulin M, A and G in patients with varicella or herpes zoster.

    PubMed Central

    van Loon, A. M.; van der Logt, J. T.; Heessen, F. W.; Heeren, M. C.; Zoll, J.

    1992-01-01

    Antibody-capture enzyme-linked immunosorbent assays (AC-ELISA) which use enzyme-labelled antigen were developed for detection of varicella-zoster virus-(VZV) specific IgM, IgA and IgG antibody in patients with varicella or herpes zoster and in sera from healthy individuals. All 18 patients with varicella developed a VZV-IgM and a VZV-IgG response, 17 also a VZV-IgA response. In contrast, all 19 patients with herpes zoster were shown to be positive for VZV-IgA whereas only 13 of these reacted positively for VZV-IgM. A VZV-IgM response was detected in only two sera from 100 healthy individuals and an IgA response in only one. The presence of virus-specific IgA and IgG in the cerebrospinal fluid as determined by AC-ELISA was a useful indicator of VZV infection of the central nervous system. By AC-ELISA, VZV-IgG was detected predominantly in sera from patients with acute or recent VZV infection. Only 14 sera from 100 healthy individuals were positive for VZV-IgG by AC-ELISA, whereas all were positive by an indirect ELISA. These results indicate that AC-ELISA's may be useful assays for determination for acute or recurrent VZV infection, but are not suitable for determination of past infection with this virus. PMID:1312479

  15. Difference between beta1-adrenoceptor autoantibodies of human and animal origin-Limitations detecting beta1-adrenoceptor autoantibodies using peptide based ELISA technology.

    PubMed

    Wenzel, Katrin; Schulze-Rothe, Sarah; Müller, Johannes; Wallukat, Gerd; Haberland, Annekathrin

    2018-01-01

    Cell-based analytics for the detection of the beta1-adrenoceptor autoantibody (beta1-AAB) are functional, yet difficult to handle, and should be replaced by easily applicable, routine lab methods. Endeavors to develop solid-phase-based assays such as ELISA to exploit epitope moieties for trapping autoantibodies are ongoing. These solid-phase-based assays, however, are often unreliable when used with human patient material, in contrast to animal derived autoantibodies. We therefore tested an immunogen peptide-based ELISA for the detection of beta1-AAB, and compared commercially available goat antibodies against the 2nd extracellular loop of human beta1-adrenoceptor (ADRB1-AB) to autoantibodies enriched from patient material. The functionality of these autoantibodies was tested in a cell based assay for comparison and their structural appearance was investigated using 2D gel electrophoresis. The ELISA showed a limit of detection for ADRB1-AB of about 1.5 nmol antibody/L when spiked in human control serum and only about 25 nmol/L when spiked in species identical (goat) matrix material. When applied to samples of human origin, the ELISA failed to identify the specific beta1-AABs. A low concentration of beta1-AAB, together with structural inconsistency of the patient originated samples as seen from the 2D Gel appearance, might contribute to the failure of the peptide based ELISA technology to detect human beta1-AABs.

  16. Evaluation of high throughput gene expression platforms using a genomic biomarker signature for prediction of skin sensitization.

    PubMed

    Forreryd, Andy; Johansson, Henrik; Albrekt, Ann-Sofie; Lindstedt, Malin

    2014-05-16

    Allergic contact dermatitis (ACD) develops upon exposure to certain chemical compounds termed skin sensitizers. To reduce the occurrence of skin sensitizers, chemicals are regularly screened for their capacity to induce sensitization. The recently developed Genomic Allergen Rapid Detection (GARD) assay is an in vitro alternative to animal testing for identification of skin sensitizers, classifying chemicals by evaluating transcriptional levels of a genomic biomarker signature. During assay development and biomarker identification, genome-wide expression analysis was applied using microarrays covering approximately 30,000 transcripts. However, the microarray platform suffers from drawbacks in terms of low sample throughput, high cost per sample and time consuming protocols and is a limiting factor for adaption of GARD into a routine assay for screening of potential sensitizers. With the purpose to simplify assay procedures, improve technical parameters and increase sample throughput, we assessed the performance of three high throughput gene expression platforms--nCounter®, BioMark HD™ and OpenArray®--and correlated their performance metrics against our previously generated microarray data. We measured the levels of 30 transcripts from the GARD biomarker signature across 48 samples. Detection sensitivity, reproducibility, correlations and overall structure of gene expression measurements were compared across platforms. Gene expression data from all of the evaluated platforms could be used to classify most of the sensitizers from non-sensitizers in the GARD assay. Results also showed high data quality and acceptable reproducibility for all platforms but only medium to poor correlations of expression measurements across platforms. In addition, evaluated platforms were superior to the microarray platform in terms of cost efficiency, simplicity of protocols and sample throughput. We evaluated the performance of three non-array based platforms using a limited set of transcripts from the GARD biomarker signature. We demonstrated that it was possible to achieve acceptable discriminatory power in terms of separation between sensitizers and non-sensitizers in the GARD assay while reducing assay costs, simplify assay procedures and increase sample throughput by using an alternative platform, providing a first step towards the goal to prepare GARD for formal validation and adaption of the assay for industrial screening of potential sensitizers.

  17. Serodiagnosis of Echinococcus spp. Infection: Explorative Selection of Diagnostic Antigens by Peptide Microarray

    PubMed Central

    List, Claudia; Qi, Weihong; Maag, Eva; Gottstein, Bruno; Müller, Norbert; Felger, Ingrid

    2010-01-01

    Background Production of native antigens for serodiagnosis of helminthic infections is laborious and hampered by batch-to-batch variation. For serodiagnosis of echinococcosis, especially cystic disease, most screening tests rely on crude or purified Echinococcus granulosus hydatid cyst fluid. To resolve limitations associated with native antigens in serological tests, the use of standardized and highly pure antigens produced by chemical synthesis offers considerable advantages, provided appropriate diagnostic sensitivity and specificity is achieved. Methodology/Principal Findings Making use of the growing collection of genomic and proteomic data, we applied a set of bioinformatic selection criteria to a collection of protein sequences including conceptually translated nucleotide sequence data of two related tapeworms, Echinococcus multilocularis and Echinococcus granulosus. Our approach targeted alpha-helical coiled-coils and intrinsically unstructured regions of parasite proteins potentially exposed to the host immune system. From 6 proteins of E. multilocularis and 5 proteins of E. granulosus, 45 peptides between 24 and 30 amino acids in length were designed. These peptides were chemically synthesized, spotted on microarrays and screened for reactivity with sera from infected humans. Peptides reacting above the cut-off were validated in enzyme-linked immunosorbent assays (ELISA). Peptides identified failed to differentiate between E. multilocularis and E. granulosus infection. The peptide performing best reached 57% sensitivity and 94% specificity. This candidate derived from Echinococcus multilocularis antigen B8/1 and showed strong reactivity to sera from patients infected either with E. multilocularis or E. granulosus. Conclusions/Significance This study provides proof of principle for the discovery of diagnostically relevant peptides by bioinformatic selection complemented with screening on a high-throughput microarray platform. Our data showed that a single peptide cannot provide sufficient diagnostic sensitivity whereas pooling several peptide antigens improved sensitivity; thus combinations of several peptides may lead the way to new diagnostic tests that replace, or at least complement conventional immunodiagnosis of echinococcosis. Our strategy could prove useful for diagnostic developments in other pathogens. PMID:20689813

  18. Analysis of pirlimycin residues in beef muscle, milk and honey by a biotin-streptavidin-amplified enzyme-linked immunosorbent assay

    USDA-ARS?s Scientific Manuscript database

    Food contamination caused by veterinary drug residues is a world-wide public health concern and requires continuous monitoring. In this paper, we describe a biotin–streptavidin-amplified ELISA (BA-ELISA) for detecting pirlimycin residues in beef, milk, and honey. The IC50 value of the BA-ELISA was...

  19. DARPA Antibody Technology Program Standardized Test Bed for Antibody Characterization: Characterization of an MS2 sdAb Produced by U.S. Naval Research Laboratory

    DTIC Science & Technology

    2016-10-01

    Program (ATP) Quality MS2 coat protein (MS2CP) Enzyme-linked immunosorbent assay ( ELISA ) 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF...3 2.6 Thermal Stress Test............................................................................................4 2.7 ELISA ...7 3.4 DSC Results .....................................................................................................10 3.5 ELISA

  20. Microarray profiles reveal that circular RNA hsa_circ_0007385 functions as an oncogene in non-small cell lung cancer tumorigenesis.

    PubMed

    Jiang, Ming-Ming; Mai, Zhi-Tao; Wan, Shan-Zhi; Chi, Yu-Min; Zhang, Xin; Sun, Bao-Hua; Di, Qing-Guo

    2018-04-01

    Circular RNAs (circRNAs) are a novel class of non-protein-coding RNA. Emerging evidence indicates that circRNAs participate in the regulation of many pathophysiological processes. This study aims to explore the expression profiles and pathological effects of circRNAs in non-small cell lung cancer (NSCLC). Human circRNAs microarray analysis was performed to screen the expression profile of circRNAs in NSCLC tissue. Expressions of circRNA and miRNA in NSCLC tissues and cells were quantified by qRTPCR. Functional experiments were performed to investigate the biological functions of circRNA, including CCK-8 assay, colony formation assay, transwell assay and xenograft in vivo assay. Human circRNAs microarray revealed a total 957 abnormally expressed circRNAs (> twofold, P < 0.05) in NSCLC tissue compared with adjacent normal tissue. In further studies, hsa_circ_0007385 was significantly up regulated in NSCLC tissue and cells. In vitro experiments with hsa_circ_0007385 knockdown resulted in significant suppression of the proliferation, migration and invasion of NSCLC cells. In vivo xenograft assay using hsa_circ_0007385 knockdown, significantly reduced tumor growth. Bioinformatics analysis and luciferase reporter assay verified the potential target miR-181, suggesting a possible regulatory pathway for hsa_circ_0007385. In summary, results suggest hsa_circ_0007385 plays a role in NSCLC tumorigenesis, providing a potential therapeutic target for NSCLC.

  1. Selected reaction monitoring (SRM) mass spectrometry without isotope labeling can be used for rapid protein quantification

    PubMed Central

    Zhi, Wenbo; Wang, Meiyao

    2014-01-01

    The validation of putative biomarker candidates has become the major bottle-neck in protein biomarker development. Conventional immunoaffinity methods are limited by the availability of antibodies and kits. Here we demonstrated the feasibility of using the selected reaction monitoring (SRM) without isotope labeling to achieve fast and reproducible quantification of serum proteins. The SRM/MRM assays for three standard serum proteins, including ceruloplasmin (CP), serum aymloid A (SAA) and sex hormone binding globulin (SHBG) have good linear ranges, generally 103 – 104. There are almost perfect correlations between SRM intensities and the loaded peptide amounts (R2 is usually ~0.99). Our data suggest that SRM/MRM is able to quantify proteins at 0.2 – 2 fmol level, which are comparable to the commercial ELISA/LUMINEX kits for these proteins. Excellent correlations between SRM/MRM and ELISA/LUMINEX assays were observed for SAA and SHBG (R2 = 0.928 and 0.851 respectively). The correlation between SRM/MRM and ELISA for CP is less desirable (R2 = 0.565). The reproducibility for SRM/MRM assays is generally very good but may depend on the proteins/peptides (R2 = 0.931 and 0.882 for SAA and SHBG, and 0.723 for CP). SRM/MRM assay without isotope labeling is a rapid and useful method for protein biomarker validation in a modest number of samples and is especially useful when other assays such as ELISA or Luminex beads are not available. PMID:21594933

  2. Establishment and optimization of monoclonal antibody-based heterologous dcELISA for 19-nortestosterone residue in bovine edible tissue.

    PubMed

    Jiang, Jinqing; Zhang, Haitang; Li, Guangling; Yang, Xuefeng; Li, Renfeng; Wang, Ziliang; Wang, Jianhua

    2012-04-01

    This paper presents the generation of monoclonal antibodies (mAbs) with high specificity against 19-nortestosterone (NT) through cell fusion procedures, and the development of mAb-based heterologous direct competitive enzyme-linked immunoabsorbent assay (dcELISA) methods to detect NT residue using one of these hybridomas (clone 3B8-E6). Under optimal experimental conditions, this assay exhibited a working range of 0.004 to 19 ng/mL with IC₅₀ and limit of detection values of 0.28 and 0.002 ng/mL, respectively, when it was run in 0.01M phosphate-buffered saline (pH 7.4). Except for minor cross-reactivity with β-boldenone (6.9%) and trenbolone (1.2%), other interference to the assay was negligible (<0.05%). No significant differences (P > 0.05) were found for IC₅₀ values when the pH of the assay buffer ranged from 6 to 8 and phosphate ion concentration was less than 20 mM. The dcELISA can tolerate higher concentrations of methanol than other organic solvents tested. When applied to bovine sample, the correlation coefficients (R) of the dcELISA and GC-MS data were 0.9918 in muscle, 0.9834 in liver, and 0.9976 in kidney. Therefore, this assay has the potential to be incorporated into a quantitative monitoring program for the rapid screening of NT residue in food. © 2012 Institute of Food Technologists®

  3. Biomarkers of Selenium Action in Prostate Cancer

    DTIC Science & Technology

    2006-03-01

    without BPH) transition zone tissue of a 42-year-old man ac- cording to previously described methods [4]. The pre- sence of contaminating epithelial...protein secreted by cells using a sensitive ELISA method . Replicating the conditions used for the microarray analyses, cells were fed fresh medium...4 Introduction Biomarkers of selenium actions in prostate tissue would be of great value in stratifying patients

  4. A Novel Pan-Flavivirus Detection and Identification Assay Based on RT-qPCR and Microarray

    PubMed Central

    Sachse, Konrad; Ziegler, Ute; Keller, Markus

    2017-01-01

    The genus Flavivirus includes arthropod-borne viruses responsible for a large number of infections in humans and economically important animals. While RT-PCR protocols for specific detection of most Flavivirus species are available, there has been also a demand for a broad-range Flavivirus assay covering all members of the genus. It is particularly challenging to balance specificity at genus level with equal sensitivity towards each target species. In the present study, a novel assay combining a SYBR Green-based RT-qPCR with a low-density DNA microarray has been developed. Validation experiments confirmed that the RT-qPCR exhibited roughly equal sensitivity of detection and quantification for all flaviviruses tested. These PCR products are subjected to hybridization on a microarray carrying 84 different oligonucleotide probes that represent all known Flavivirus species. This assay has been used as a screening and confirmation tool for Flavivirus presence in laboratory and field samples, and it performed successfully in international External Quality Assessment of NAT studies. Twenty-six Flavivirus strains were tested with the assay, showing equivalent or superior characteristics compared with the original or even with species-specific RT-PCRs. As an example, test results on West Nile virus detection in a panel of 340 mosquito pool samples from Greece are presented. PMID:28626758

  5. Development of an enzyme-linked immunosorbent assay and a beta-1 adrenergic receptor-based assay for monitoring the drug atenolol.

    PubMed

    Sapir, A; Shalev, A Hariton; Skalka, N; Bronshtein, A; Altstein, M

    2013-03-01

    Two approaches for monitoring atenolol (ATL) were applied: an immunochemical assay and a competitive-binding assay, based on the interaction between ATL and its target receptor, β1 adrenergic receptor (β1AR). Polyclonal antibodies (Abs) for ATL were generated, and a highly specific microplate immunochemical assay, that is, an enzyme-linked immunosorbent assay (ELISA), for its detection was developed. The ATL ELISA exhibited I50 and limit of detection (I20) values of 0.15 ± 0.048 and 0.032 ± 0.016 ng/ml, respectively, and the Abs did not cross-react with any of the tested beta-blocker drugs. Furthermore, a human β1AR (h-β1AR) was stably expressed in Spodoptera frugiperda cells (Sf9). The receptor was employed to develop a competitive-binding assay that monitored binding of ATL in the presence of isoproteranol by quantification of secondary messenger, cyclic adenosine monophosphate (cAMP), levels in the transfected cells. The assay showed that the recombinant h-β1AR was functional, could bind the agonistic ligand isoproterenol as well as the antagonist ATL, as indicated by a dose-dependent elevation of cAMP in the presence of isoproteranol, and decrease after ATL addition. The highly efficient and sensitive ELISA and the receptor assay represent two methods suitable for efficient and cost-effective large-scale, high-throughput monitoring of ATL in environmental, agricultural, and biological samples. Copyright © 2012 SETAC.

  6. Characterization of inhibin forms and their measurement by an inhibin alpha-subunit ELISA in serum from postmenopausal women with ovarian cancer.

    PubMed

    Robertson, D M; Stephenson, T; Pruysers, E; McCloud, P; Tsigos, A; Groome, N; Mamers, P; Burger, H G

    2002-02-01

    The aim of this study was to characterize the molecular wt forms of inhibins A and B and its free alpha-subunit present in serum from women with ovarian cancer as a basis for developing improved monoclonal antibody-based inhibin assays for monitoring ovarian cancer. Three new inhibin alpha-subunit (alphaC) ELISAs were developed using monoclonal antibodies directed to three nonoverlapping peptide regions of the alphaC region of the inhibin alpha-subunit. To characterize serum inhibin molecular wt forms present in women with ovarian cancer, existing inhibin immunoassays (inhibin A, inhibin B, and pro-alphaC) and the new alphaC ELISAs were applied to sera from women with granulosa cell tumors and mucinous carcinomas previously fractionated using a combined immunoaffinity chromatography, preparative SDS-PAGE, and electroelution procedure. The distribution and molecular size of dimeric inhibins and alpha-subunit detected were consistent with known mol wt forms of inhibins A and B and inhibin alpha-subunit and their precursor forms present in serum and follicular fluid from healthy women. The alphaC ELISAs recognized all known forms of inhibin and the free inhibin alpha-subunit, although differences between alphaC ELISAs were observed in their ability to detect high mol wt forms. To assess which of the alphaC ELISAs was preferred in application to ovarian cancer, the alphaC ELISAs were applied to serum from a range of normal postmenopausal women (n = 61) and postmenopausal women (n = 152) with ovarian (serous, mucinous, endometrioid, clear cell carcinomas, and granulosa cell tumors) and nonovarian (breast and colon) cancers. Despite differences in their ability to detect high mol wt forms of inhibin, the alphaC ELISAs showed similar sensitivity (i.e. proportion of cancer patients correctly detected) and specificity (proportion of controls correctly detected) indexes in the detection of mucinous carcinomas (84% and 95%) and granulosa cell tumors (100% and 95%) compared with earlier inhibin RIA or polyclonal antibody-based immunofluorometric assays. A combination of the alphaC ELISAs with the CA125 assay, an ovarian tumor marker that has a high sensitivity and specificity for other ovarian cancers (serous, clear cell, and endometrioid), resulted in an increase in sensitivity/specificity indexes (95% and 95%) for the all ovarian cancer group. These new monoclonal antibody-based inhibin alphaC ELISAs now provide practical and sensitive assays suitable for evaluation as diagnostic tests for monitoring ovarian cancers.

  7. Performance of commercial dengue NS1 ELISA and molecular analysis of NS1 gene of dengue viruses obtained during surveillance in Indonesia.

    PubMed

    Aryati, Aryati; Trimarsanto, Hidayat; Yohan, Benediktus; Wardhani, Puspa; Fahri, Sukmal; Sasmono, R Tedjo

    2013-12-29

    Early diagnosis of dengue infection is crucial for better management of the disease. Diagnostic tests based on the detection of dengue virus (DENV) Non Structural Protein 1 (NS1) antigen are commercially available with different sensitivities and specificities observed in various settings. Dengue is endemic in Indonesia and clinicians are increasingly using the NS1 detection for dengue confirmation. This study described the performance of Panbio Dengue Early NS1 and IgM Capture ELISA assays for dengue detection during our surveillance in eight cities in Indonesia as well as the genetic diversity of DENV NS1 genes and its relationship with the NS1 detection. The NS1 and IgM/IgG ELISA assays were used for screening and confirmation of dengue infection during surveillance in 2010-2012. Collected serum samples (n = 440) were subjected to RT-PCR and virus isolation, in which 188 samples were confirmed for dengue infection. The positivity of the ELISA assays were correlated with the RT-PCR results to obtain the sensitivity of the assays. The NS1 genes of 48 Indonesian virus isolates were sequenced and their genetic characteristics were studied. Using molecular data as gold standard, the sensitivity of NS1 ELISA assay for samples from Indonesia was 56.4% while IgM ELISA was 73.7%. When both NS1 and IgM results were combined, the sensitivity increased to 89.4%. The NS1 sensitivity varied when correlated with city/geographical origins and DENV serotype, in which the lowest sensitivity was observed for DENV-4 (19.0%). NS1 sensitivity was higher in primary (67.6%) compared to secondary infection (48.2%). The specificity of NS1 assay for non-dengue samples were 100%. The NS1 gene sequence analysis of 48 isolates revealed the presence of polymorphisms of the NS1 genes which apparently did not influence the NS1 sensitivity. We observed a relatively low sensitivity of NS1 ELISA for dengue detection on RT-PCR-positive dengue samples. The detection rate increased significantly when NS1 data was combined with IgM. In our study, the low sensitivity of NS1 antigen detection did not relate to NS1 genetic diversity. Rather, the performance of the NS1 antigen test was affected by the infection status of patients and geographical origin of samples.

  8. The feasibility of harmonizing gluten ELISA measurements.

    PubMed

    Rzychon, Malgorzata; Brohée, Marcel; Cordeiro, Fernando; Haraszi, Reka; Ulberth, Franz; O'Connor, Gavin

    2017-11-01

    Many publications have highlighted that routine ELISA methods do not give rise to equivalent gluten content measurement results. In this study, we assess this variation between results and its likely impact on the enforcement of the EU gluten-free legislation. This study systematically examines the feasibility of harmonizing gluten ELISA assays by the introduction of: a common extraction procedure; a common calibrator, such as a pure gluten extract and an incurred matrix material. The comparability of measurements is limited by a weak correlation between kit results caused by differences in the selectivity of the methods. This lack of correlation produces bias that cannot be corrected by using reference materials alone. The use of a common calibrator reduced the between-assay variability to some extent, but variation due to differences in selectivity of the assays was unaffected. Consensus on robust markers and their conversion to "gluten content" are required. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  9. Sensitive, fast, and specific immunoassays for methyltestosterone detection.

    PubMed

    Kong, Na; Song, Shanshan; Peng, Juan; Liu, Liqiang; Kuang, Hua; Xu, Chuanlai

    2015-04-29

    An indirect competitive enzyme-linked immunosorbent assay (icELISA) and an immunochromatographic strip assay using a highly specific monoclonal antibody, were developed to detect methyltestosterone (MT) residues in animal feed. The optimized icELISA had a half-inhibition concentration value of 0.26 ng/mL and a limit of detection value of 0.045 ng/mL. There was no cross-reactivity with eight analogues, revealing high specificity for MT. Based on icELISA results, the recovery rate of MT in animal feed was 82.4%-100.6%. The results were in accordance with those obtained by gas chromatography-mass spectrometry. The developed immunochromatographic strip assay, as the first report for MT detection, had a visual cut-off value of 1 ng/mL in PBS, 2.5 ng/g in fish feed, and 2.5 ng/g in pig feed. Therefore, these immunoassays are useful and fast tools for MT residue detection in animal feed.

  10. Monoclonal antibody-based serological assays and immunocapture-RT-PCR for detecting Rice dwarf virus in field rice plants and leafhopper vectors.

    PubMed

    Wu, Jianxiang; Ni, Yuequn; Liu, Huan; Ding, Ming; Zhou, Xueping

    2014-01-01

    Rice dwarf virus (RDV) causes Rice dwarf disease, which leads to considerable losses in rice production in Asia. Purified RDV virions were used as the immunogen to prepare monoclonal antibodies (mAbs). Three murine mAbs against RDV were prepared. Plate-trapped antigen enzyme-linked immunosorbent assay (PTA-ELISA), dot enzyme-linked immunosorbent assay (dot-ELISA) and immunocapture-RT-PCR (IC-RT-PCR) were then developed for sensitive, specific, and rapid detection of RDV in rice and leafhopper samples obtained in the field using the mAbs. The PTA-ELISA, dot-ELISA and IC-RT-PCR detected the virus in infected tissue crude extracts diluted at 1:81,920, 1:10,240 and 1:655,360 (w/v, g mL(-1)), in individual viruliferous rice green leafhopper crude extracts diluted at 1:25,600, 1:6400 and 1:3,276,800 (individual leafhopper/μL), respectively. 878 rice field samples and 531 leafhopper field samples from ten provinces of China were screened for the presence of RDV using the two serological assays and the IC-RT-PCR and the results indicated that 37 of the 878 rice samples and 22 of the 531 leafhopper samples were infected by RDV. All positive samples were from Yunnan Province, indicating that RDV is prevalent in this province, but not in the other nine provinces. The dot-ELISA is suitable for routine detection of large-scale rice and leafhopper samples in field surveys. Copyright © 2013 Elsevier B.V. All rights reserved.

  11. A novel in-cell ELISA method for screening of compounds inhibiting TRKA phosphorylation, using KM12 cell line harboring TRKA rearrangement.

    PubMed

    Pandre, Manoj Kumar; Shaik, Shama; Satya Pratap, Veera Venkata Valluri; Yadlapalli, Prasad; Yanamandra, Mahesh; Mitra, Sayan

    2018-03-15

    Tropomyosin-related kinase A (TRKA) fusion was originally detected in colorectal carcinoma that had resulted in expression of the oncogenic chimeric protein TPM3-TRKA. Lately, many more rearrangements in TRK family of kinases generating oncogenic fusion proteins have been identified. These genetic rearrangements usually result in fusion of cytoplasmic kinase domain of TRK to another gene of interest resulting in constitutive kinase activity. Estimation of TRK inhibitor potency in a cellular context is required for drug discovery programs and is measured by receptor phosphorylation levels upon compound administration. However, since a large chunk of the TRK protein is lost in this rearrangement, it's difficult to set up sandwich ELISA for detection of receptor phosphorylation in any cell assay harboring these fusion proteins. In order to address this issue, we developed a novel and robust in-cell ELISA method which quantifies the phosphorylation of TRK kinase (Tyr 674/675) within the KM12 cells. This cell based method is more versatile & economical than conventional ELISA using engineered overexpressing cell line and/or western blot methods. Performance reliability & robustness for the validated assay were determined by %CV and Z factor in assays with reference molecule larotrectinib. This in-cell ELISA method can be used with any TRKA rearranged oncogenic fusion cell type and can be extended to other TRK isoforms as well. We have used this assay to screen novel molecules in KM12 cells and to study pharmacodynamic properties of compounds in TRKA signaling. Copyright © 2018 Elsevier Inc. All rights reserved.

  12. Development of a highly sensitive and specific monoclonal antibody based enzyme-linked immunosorbent assay for the detection of a new β-agonist, phenylethanolamine A, in food samples.

    PubMed

    Jiang, Danni; Cao, Biyun; Wang, Meiyu; Yang, Hong; Zhao, Kang; Li, Jianguo; Li, Mingxin; Sun, Lulu; Deng, Anping

    2017-02-01

    All β-agonists are banned as feed additives for growth promotion in animals due to toxic effects on humans after consuming the β-agonist contaminated meats. Phenylethanolamine A (PA) is a newly emerged β-agonist. Thus there is a need to develop highly sensitive and specific analytical methods for the detection of PA in food samples. In this study, the monoclonal antibody (mAb) against PA was produced by hybridoma technology and used for the development of enzyme-linked immunosorbent assay (ELISA). The IC 50 values and limits of detection (LODs) of the ELISA using homogeneous combination of coating antigen/antibody for PA were 0.16 ng mL -1 and 0.011 ng mL -1 , respectively. The cross-reactive (CR) values of the assay with 14 structurally related β-agonists were lower than 0.59%. Swine liver and meat samples were spiked with PA at different content and analysed by ELISA. Acceptable recovery rates of 91.40-105.51% and intra-assay coefficients of variation of 1.56-9.92% (n = 3) were obtained. The ELISA for seven spiked samples was confirmed by LC-MS/MS with a high correlation coefficient of 0.9881. The proposed mAb-based ELISA was highly sensitive and specific for PA and could be used as a quantitative/screening method for PA analysis in food samples. © 2016 Society of Chemical Industry. © 2016 Society of Chemical Industry.

  13. Undercarboxylated osteocalcin measured with a specific immunoassay predicts hip fracture in elderly women: the EPIDOS Study.

    PubMed

    Vergnaud, P; Garnero, P; Meunier, P J; Bréart, G; Kamihagi, K; Delmas, P D

    1997-03-01

    Increased levels of circulating undercarboxylated osteocalcin (ucOC), measured indirectly with the hydroxyapatite (HAP) binding assay, have been shown to predict hip fracture risk in a small group of elderly institutionalized women. The aim of this study was to confirm these findings in a prospective cohort study (EPIDOS prospective study) of 7598 healthy, independently living women over 75 yr of age. One hundred and four women who sustained a hip fracture during a 22-month follow-up period were age matched with 255 controls who did not fracture. Baseline samples were collected before hip fracture for measurement of total OC and ucOC, assessed either with the HAP binding assay or directly with a new enzyme-linked immunosorbent assay (ELISA). This direct ELISA uses human recombinant noncarboxylated OC as a standard and two monoclonal antibodies, one of which was raised against the 14-30 Glu synthetic peptide. We found that the intra- and interassay variations are less than 11%, and this assay exhibits a 5% cross-reactivity with purified human bone OC, used as a source of carboxylated OC. ucOC levels measured with this ELISA correlated well with the HAP binding assay in the population of 359 elderly women (r = 0.82; P < 0.0001). We estimated the risk of hip fracture for women with levels of ucOC in the highest quartile of values for the 255 controls. We found that increased levels of ucOC measured by ELISA were associated with increased hip fracture risk with an odds ratio (OR) of 1.9 (95% confidence interval, 1.2-3.0), and the ELISA had a greater sensitivity than the HAP assay. In contrast, total OC was not associated with hip fracture risk. After adjustment for femoral neck bone mineral density (BMD) and mobility status assessed by gait speed, ucOC still predicted hip fracture with an OR of 1.8 (1.0-3.0). Women with both femoral neck BMD in the lowest quartile and ucOC in the highest quartile were at higher risk of hip fracture, with an OR of 5.5 (2.7-11.2), than those with only low BMD or high ucOC levels. In conclusion, we have developed a new specific ELISA for serum ucOC, with low cross-reactivity with carboxylated OC and increased specificity and sensitivity over the HAP assay. Using this new ELISA, we found that ucOC, but not total OC, predicts hip fracture risk independently of femoral neck BMD in elderly women drawn from the general population. Thus, ucOC measurement could be combined with bone mass determination to improve the assessment of hip fracture risk in elderly women.

  14. 9 CFR 147.7 - Standard test procedures for mycoplasma. 5

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... plate agglutination test, the tube agglutination test, and the enzyme-linked immunosorbent assay (ELISA... accurate however, and are useful in evaluating serum samples that react with the ELISA, plate, and/or tube...

  15. 9 CFR 147.7 - Standard test procedures for mycoplasma. 5

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... plate agglutination test, the tube agglutination test, and the enzyme-linked immunosorbent assay (ELISA... accurate however, and are useful in evaluating serum samples that react with the ELISA, plate, and/or tube...

  16. 9 CFR 147.7 - Standard test procedures for mycoplasma. 5

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... plate agglutination test, the tube agglutination test, and the enzyme-linked immunosorbent assay (ELISA... accurate however, and are useful in evaluating serum samples that react with the ELISA, plate, and/or tube...

  17. The Dot Blot ELISA.

    ERIC Educational Resources Information Center

    Gerbig, Donald G., Jr.; Fenk, Christopher J.; Goodhart, Amy S.

    2000-01-01

    Uses two laboratory techniques, Enzyme Linked Immunosorbent Assay (ELISA) and Western Blot, to demonstrate antibody-antigen binding concepts. Includes a list of required materials and directions for the procedure, and makes suggestions for classroom applications. (Contains 13 references.) (YDS)

  18. 9 CFR 147.6 - Procedure for determining the status of flocks reacting to tests for Mycoplasma gallisepticum...

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... agglutination test, enzyme-labeled immunosorbent assay (ELISA), official molecular examination procedure, or... the tube agglutination, ELISA, or serum plate test is positive, the hemaglutination inhibition (HI...

  19. 9 CFR 147.6 - Procedure for determining the status of flocks reacting to tests for Mycoplasma gallisepticum...

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... agglutination test, enzyme-labeled immunosorbent assay (ELISA), official molecular examination procedure, or... the tube agglutination, ELISA, or serum plate test is positive, the hemaglutination inhibition (HI...

  20. 9 CFR 147.7 - Standard test procedures for mycoplasma. 5

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... plate agglutination test, the tube agglutination test, and the enzyme-linked immunosorbent assay (ELISA... accurate however, and are useful in evaluating serum samples that react with the ELISA, plate, and/or tube...

  1. 9 CFR 147.6 - Procedure for determining the status of flocks reacting to tests for Mycoplasma gallisepticum...

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... agglutination test, enzyme-labeled immunosorbent assay (ELISA), official molecular examination procedure, or... the tube agglutination, ELISA, or serum plate test is positive, the hemaglutination inhibition (HI...

  2. 9 CFR 147.7 - Standard test procedures for mycoplasma. 5

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... plate agglutination test, the tube agglutination test, and the enzyme-linked immunosorbent assay (ELISA... accurate however, and are useful in evaluating serum samples that react with the ELISA, plate, and/or tube...

  3. Monoclonal antibody-based serological methods for detecting Citrus tristeza virus in citrus groves.

    PubMed

    Liu, Zhen; Chen, Zhe; Hong, Jian; Wang, Xuefeng; Zhou, Changyong; Zhou, Xueping; Wu, Jianxiang

    2016-08-01

    Citrus tristeza virus (CTV) is one of the most economically important citrus viruses and harms the citrus industry worldwide. To develop reliable and effective serological detection assays of CTV, the major capsid protein (CP) gene of CTV was expressed in Escherichia coli BL21 (DE3) using the expression vector pET-28a and purified through Ni+-NTA affinity chromatography. The recombinant protein was used to immunize BALB/c mice. Four hybridoma cell lines (14B10, 14H11, 20D5, and 20G12) secreting monoclonal antibodies (MAbs) against CTV were obtained through conventional hybridoma technology. The titers of MAb-containing ascitic fluids secreted by the four hybridoma lines ranged from 10(-6) to 10(-7) in indirect enzyme-linked immunosorbent assay (ELISA). Western blots showed that all four MAbs could specifically react with CTV CP. Using the prepared MAbs, dot-ELISA, Tissue print-ELISA, and triple antibody sandwich (TAS)-ELISA were developed to detect CTV in tree nurseries and epidemiological studies. The developed dot-ELISA and TAS-ELISA methods could detect CTV in crude extracts of infected citrus leaves with dilutions of 1:2560 and 1:10, 240 (w/v, g/mL), respectively. Tissue print-ELISA was particularly useful for large-scale field sample detection, mainly owing to its simplicity and lack of sample preparation requirements. The field survey revealed that CTV is prevalent on citrus trees in the Chongqing Municipality, Jiangxi Province, and Zhejiang Province of China. The coincidence rate of serological and RT-PCR test results reached more than 99.5%. The prepared MAbs against CTV and established sensitive and specific serological assays have a significant role in the detection and prevention and control of CTV in our country.

  4. Multi-Gene Detection and Identification of Mosquito-Borne RNA Viruses Using an Oligonucleotide Microarray

    PubMed Central

    Grubaugh, Nathan D.; McMenamy, Scott S.; Turell, Michael J.; Lee, John S.

    2013-01-01

    Background Arthropod-borne viruses are important emerging pathogens world-wide. Viruses transmitted by mosquitoes, such as dengue, yellow fever, and Japanese encephalitis viruses, infect hundreds of millions of people and animals each year. Global surveillance of these viruses in mosquito vectors using molecular based assays is critical for prevention and control of the associated diseases. Here, we report an oligonucleotide DNA microarray design, termed ArboChip5.1, for multi-gene detection and identification of mosquito-borne RNA viruses from the genera Flavivirus (family Flaviviridae), Alphavirus (Togaviridae), Orthobunyavirus (Bunyaviridae), and Phlebovirus (Bunyaviridae). Methodology/Principal Findings The assay utilizes targeted PCR amplification of three genes from each virus genus for electrochemical detection on a portable, field-tested microarray platform. Fifty-two viruses propagated in cell-culture were used to evaluate the specificity of the PCR primer sets and the ArboChip5.1 microarray capture probes. The microarray detected all of the tested viruses and differentiated between many closely related viruses such as members of the dengue, Japanese encephalitis, and Semliki Forest virus clades. Laboratory infected mosquitoes were used to simulate field samples and to determine the limits of detection. Additionally, we identified dengue virus type 3, Japanese encephalitis virus, Tembusu virus, Culex flavivirus, and a Quang Binh-like virus from mosquitoes collected in Thailand in 2011 and 2012. Conclusions/Significance We demonstrated that the described assay can be utilized in a comprehensive field surveillance program by the broad-range amplification and specific identification of arboviruses from infected mosquitoes. Furthermore, the microarray platform can be deployed in the field and viral RNA extraction to data analysis can occur in as little as 12 h. The information derived from the ArboChip5.1 microarray can help to establish public health priorities, detect disease outbreaks, and evaluate control programs. PMID:23967358

  5. Comparative analysis of the diagnostic performance of crude sheep hydatid cyst fluid, purified antigen B and its subunit (12 Kda), assessed by ELISA, in the diagnosis of human cystic echinococcosis.

    PubMed

    Tawfeek, Gihan M; Elwakil, Hala S; El-Hoseiny, Laila; Thabet, Hala S; Sarhan, Rania M; Awad, Nabil S; Anwar, Wagida A

    2011-02-01

    The diagnosis of patients with cystic echinococcosis (CE) by means of serology has a limited support in clinical practice due to cross-reactivity with other helminthes leading to overestimation of the parasite's true prevalence. A wealth of reports on the diagnostic performance of antigen B (AgB) has been produced. This study was designed to comparatively assess the diagnostic efficacy of crude sheep hydatid cyst fluid (HCF), AgB and its subunit (12 KDa) to detect IgG or IgG4 antibodies in CE patients' sera using enzyme-linked immunosorbent assay (ELISA).The best diagnostic performance was obtained with anti-HCF IgG ELISA which gave 92.4% sensitivity and 92.6% specificity. Despite the low sensitivity of anti AgB IgG ELISA (84%), it gave the best specificity (94.4%) with less cross-reaction with sera of subjects infected with other parasites. In conclusion, it is recommended to use anti-HCF IgG ELISA for initial screening in large seroprevalence studies. Further analysis of positive serum samples with anti AgB IgG ELISA would allow the confirmation of true positives. Specific IgG4 ELISA may represent a complementary assay, useful as secondary confirmatory tests for patients with suspected CE and negative for total IgG ELISA.

  6. Improved quantification of a commercial enzyme-linked immunosorbent assay kit for measuring anti-MDA5 antibody.

    PubMed

    Gono, Takahisa; Okazaki, Yuka; Murakami, Akihiro; Kuwana, Masataka

    2018-04-09

    To compare the quantitative performance for measuring anti-MDA5 antibody titer of two enzyme-linked immunosorbent assay (ELISA) systems: an in-house ELISA and the commercial MESACUP TM anti-MDA5 test. Anti-MDA5 antibody titer was measured in sera from 70 patients with dermatomyositis using an in-house ELISA and the MESACUP TM anti-MDA5 test side-by-side. For the commercial ELISA kit, serum samples diluted 1:101 were used according to the manufacturer's protocol, but serial dilutions of sera were also examined to identify the optimal serum dilution for quantification. The anti-MDA5 antibody titers measured by the in-house and commercial ELISAs were positively correlated with each other (r = 0.53, p = .0001), but the antibody titer measured by the commercial ELISA was less sensitive to change after medical treatment, and 37 (80%) of 46 anti-MDA5-positive sera had antibody titer exceeding the quantification range specified by the manufacturer (≥150 index). Experiments using diluted serum samples revealed that diluting the sera 1:5050 improved the quantitative performance of the MESACUP TM anti-MDA5 test, including a better correlation with the in-house ELISA results and an increased sensitivity to change. We improved the ability of the commercial ELISA kit to quantify anti-MDA5 antibody titer by altering its protocol.

  7. A Colorimetric Enzyme-Linked Immunosorbent Assay (ELISA) Detection Platform for a Point-of-Care Dengue Detection System on a Lab-on-Compact-Disc.

    PubMed

    Thiha, Aung; Ibrahim, Fatimah

    2015-05-18

    The enzyme-linked Immunosorbent Assay (ELISA) is the gold standard clinical diagnostic tool for the detection and quantification of protein biomarkers. However, conventional ELISA tests have drawbacks in their requirement of time, expensive equipment and expertise for operation. Hence, for the purpose of rapid, high throughput screening and point-of-care diagnosis, researchers are miniaturizing sandwich ELISA procedures on Lab-on-a-Chip and Lab-on-Compact Disc (LOCD) platforms. This paper presents a novel integrated device to detect and interpret the ELISA test results on a LOCD platform. The system applies absorption spectrophotometry to measure the absorbance (optical density) of the sample using a monochromatic light source and optical sensor. The device performs automated analysis of the results and presents absorbance values and diagnostic test results via a graphical display or via Bluetooth to a smartphone platform which also acts as controller of the device. The efficacy of the device was evaluated by performing dengue antibody IgG ELISA on 64 hospitalized patients suspected of dengue. The results demonstrate high accuracy of the device, with 95% sensitivity and 100% specificity in detection when compared with gold standard commercial ELISA microplate readers. This sensor platform represents a significant step towards establishing ELISA as a rapid, inexpensive and automatic testing method for the purpose of point-of-care-testing (POCT) in resource-limited settings.

  8. Evaluation of Multiple Immunoassay Technology Platforms to Select the Anti-Drug Antibody Assay Exhibiting the Most Appropriate Drug and Target Tolerance

    PubMed Central

    Collet-Brose, Justine

    2016-01-01

    The aim of this study was, at the assay development stage and thus with an appropriate degree of rigor, to select the most appropriate technology platform and sample pretreatment procedure for a clinical ADA assay. Thus, ELISA, MSD, Gyrolab, and AlphaLISA immunoassay platforms were evaluated in association with target depletion and acid dissociation sample pretreatment steps. An acid dissociation step successfully improved the drug tolerance for all 4 technology platforms and the required drug tolerance was achieved with the Gyrolab and MSD platforms. The target tolerance was shown to be better for the ELISA format, where an acid dissociation treatment step alone was sufficient to achieve the desired target tolerance. However, inclusion of a target depletion step in conjunction with the acid treatment raised the target tolerance to the desired level for all of the technologies. A higher sensitivity was observed for the MSD and Gyrolab assays and the ELISA, MSD, and Gyrolab all displayed acceptable interdonor variability. This study highlights the usefulness of evaluating the performance of different assay platforms at an early stage in the assay development process to aid in the selection of the best fit-for-purpose technology platform and sample pretreatment steps. PMID:27243038

  9. Immunocapture loop-mediated isothermal amplification assays for the detection of canine parvovirus.

    PubMed

    Sun, Yu-Ling; Yen, Chon-Ho; Tu, Ching-Fu

    2017-11-01

    A loop-mediated isothermal amplification (LAMP) assay was used for rapid canine parvovirus (CPV) diagnosis. To reduce the time required and increase the sensitivity of the assay, an immunocapture (IC) technique was developed in this study to exclude the DNA extraction step in molecular diagnostic procedures for CPV. A polyclonal rabbit anti-CPV serum was produced against VP2-EpC that was cloned via DNA recombination. The polyclonal anti-VP2-EpC serum was used for virus capture to prepare microtubes. IC-LAMP was performed to amplify a specific CPV target gene sequence from the CPV viral particles that were captured on the microtubes, and the amplicons were analyzed using agarose electrophoresis or enzyme-linked immunosorbent assay (IC-LAMP-ELISA) and lateral-flow dipstick (IC-LAMP-LFD). The detection sensitivities of IC-LAMP, IC-LAMP-ELISA, and IC-LAMP-LFD were 10 -1 , 10 -1 , and 10 -1 TCID 50 /mL, respectively. Using the IC-LAMP-ELISA and IC-LAMP-LFD assays, the complete CPV diagnostic process can be achieved within 1.5h. Both of the developed IC-LAMP-based assays are simple, direct visual and efficient techniques that are applicable to the detection of CPV. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Poly(acrylic acid) brushes pattern as a 3D functional biosensor surface for microchips

    NASA Astrophysics Data System (ADS)

    Wang, Yan-Mei; Cui, Yi; Cheng, Zhi-Qiang; Song, Lu-Sheng; Wang, Zhi-You; Han, Bao-Hang; Zhu, Jin-Song

    2013-02-01

    Poly(acrylic acid) (PAA) brushes, a novel three dimensional (3D) precursor layer of biosensor or protein microarrays, possess high protein loading level and low non-specific protein adsorption. In this article, we describe a simple and convenient way to fabricate 3D PAA brushes pattern by microcontact printing (μCP) and characterize it with FT-IR and optical microscopy. The carboxyl groups of PAA brushes can be applied to covalently immobilize protein for immunoassay. Thriving 3D space made by patterning PAA brushes thin film is available to enhance protein immobilization, which is confirmed by measuring model protein interaction between human immunoglobulin G (H-IgG) and goat anti-H-IgG (G-H-IgG) with fluorescence microscopy and surface plasmon resonance imaging (SPRi). As expected, the SPRi signals of H-IgG coating on 3D PAA brushes pattern and further measuring specific binding with G-H-IgG are all larger than that of 3D PAA brushes without pattern and 2D bare gold surface. We further revealed that this surface can be used for high-throughput screening and clinical diagnosis by label-free assaying of Hepatitis-B-Virus surface antibody (HBsAb) with Hepatitis-B-Virus surface antigen (HBsAg) concentration array chip. The linearity range for HBsAb assay is wider than that of conventional ELISA method.

  11. Highly sensitive immuno-assays for the determination of cotinine in serum and saliva. Comparison between RIA and an avidin-biotin ELISA.

    PubMed

    Benkirane, S; Nicolas, A; Galteau, M M; Siest, G

    1991-06-01

    Two immuno-assay methods (RIA and ELISA) have been developed for the accurate and sensitive measurement of cotinine in human body fluids (serum, saliva). RIA uses [3H]cotinine as antigen and charcoal/dextran for separating cotinine-bound antibodies from the free derivative. Another technique (ELISA) was developed to avoid the use of radio-labelled compounds and to determine cotinine in large populations, including passive or non-smokers who usually present very low concentrations. The two techniques were analytically validated. The detection limit was similar (0.1 micrograms/l) and the precision was better than 10% for both techniques. Non-smoker values ranged from 0.1 to 17 micrograms/l by ELISA and 0.1 to 27.5 micrograms/l by RIA, whereas smoker values ranged from 50 to 1000 micrograms/l (ELISA) and from 70 to 800 micrograms/l (RIA). The comparative analysis of cotinine in 96 human sera revealed a good correlation between the two methods (r = 0.97) and a reliable discrimination between the populations of non-smokers and smokers. As usual, the ELISA is more rapid (4 h 30 min) than the RIA (longer than 48 h). ELISA is proposed for use in the epidemiological investigation of the human tobacco risk.

  12. G-protein based ELISA as a potency test for rabies vaccines.

    PubMed

    Chabaud-Riou, Martine; Moreno, Nadège; Guinchard, Fabien; Nicolai, Marie Claire; Niogret-Siohan, Elisabeth; Sève, Nicolas; Manin, Catherine; Guinet-Morlot, Françoise; Riou, Patrice

    2017-03-01

    The NIH test is currently used to assess the potency of rabies vaccine, a key criterion for vaccine release. This test is based on mice immunization followed by intracerebral viral challenge. As part of global efforts to reduce animal experimentation and in the framework of the development of Sanofi Pasteur next generation, highly-purified vaccine, produced without any material of human or animal origin, we developed an ELISA as an alternative to the NIH test. This ELISA is based on monoclonal antibodies recognizing specifically the native form of the viral G-protein, the major antigen that induces neutralizing antibody response to rabies virus. We show here that our ELISA is able to distinguish between potent and different types of sub-potent vaccine lots. Satisfactory agreement was observed between the ELISA and the NIH test in the determination of the vaccine titer and their capacity to discern conform from non-conform batches. Our ELISA meets the criteria for a stability-indicating assay and has been successfully used to develop the new generation of rabies vaccine candidates. After an EPAA international pre-collaborative study, this ELISA was selected as the assay of choice for the EDQM collaborative study aimed at replacing the rabies vaccine NIH in vivo potency test. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  13. Development of enzyme-linked immunosorbent assay (ELISA) for glutathione S-transferase (GST-S) protein in the intertidal copepod Tigriopus japonicus and its application for environmental monitoring.

    PubMed

    Rhee, Jae-Sung; Kim, Bo-Mi; Jeong, Chang-Bum; Leung, Kenneth Mei Yee; Park, Gyung Soo; Lee, Jae-Seong

    2013-11-01

    To utilize the GST-S protein as a useful biomarker for environmental contamination, we developed a polyclonal antibody-based enzyme-linked immunosorbent assay (ELISA) in the intertidal copepod Tigriopus japonicus. Two polyclonal antibodies, TJ-GST-S1 and TJ-GST-S2, were raised against two TJ-GST-S synthetic peptides. Also a recombinant TJ-GST-S protein was purified as a standard for ELISA development. Each polyclonal antibody was tested by Western blot analysis and indirect ELISA. Of two polyclonal antibodies, TJ-GST-S2 ELISA was further employed due to its wide range of detection and the limit of specificity compared to those of TJ-GST-S1 ELISA system. After exposure to 4 metals (Ag, As, Cd, and Cu) to T. japonicus, the amount of TJ-GST-S protein was significantly elevated in a concentration-dependent manner. Also, TJ-GST-S protein was upregulated at relative high concentrations of B[α]P, PCB, and TBT. In this paper, we suggest that T. japonicas ELISA for TJ-GST-S2 is useful as a potential indicator system for marine contaminants. Copyright © 2013 Elsevier Ltd. All rights reserved.

  14. Determination of the folate content in cladodes of nopal (Opuntia ficus indica) by microbiological assay utilizing Lactobacillus casei (ATCC 7469) and enzyme-linked immunosorbent assay.

    PubMed

    Ortiz-Escobar, Tania Breshkovskaya; Valverde-González, Maria Elena; Paredes-López, Octavio

    2010-05-26

    Prickly pear cactus has been an important food source in Mexico since ancient times due to its economical and ecological benefits and potential nutraceutical value. Nevertheless, studies on the nutritional aspects and health benefits have been scarce. The purpose of this study was to assess, apparently for the first time, the folate contents of cladodes of nopal by a microbiological assay, using Lactobacillus casei (ATCC 7469) in extracts that were enzymatically treated to release the bound vitamin, employing single, dual, and trienzymatic procedures, and using the enzyme-linked immunosorbent assay (ELISA). We used Opuntia cladodes of different length sizes. The microbiological assay showed some differences among enzyme treatments and sizes of nopal; the trienzyme treatment (alpha-amylase-protease-conjugase) was more efficient in determining the folate content in nopal, giving 5.0 ng/g in the small size cladodes at 54 h of testing time, while ELISA showed no significant differences in the folate content among sizes of cladodes (5.5-5.62 ng/g at 0 min testing time). Both techniques may be used for the assessment of folate content in cladodes, but ELISA is more rapid and reliable.

  15. Simple Identification of Human Taenia Species by Multiplex Loop-Mediated Isothermal Amplification in Combination with Dot Enzyme-Linked Immunosorbent Assay

    PubMed Central

    Nkouawa, Agathe; Sako, Yasuhito; Okamoto, Munehiro; Ito, Akira

    2016-01-01

    For differential detection of Taenia solium, Taenia saginata, and Taenia asiatica, loop-mediated isothermal amplification (LAMP) assay targeting the cytochrome c oxidase subunit 1 gene has been recently developed and shown to be sensitive, specific, and effective. However, to achieve differential identification, one specimen requires three reaction mixtures containing a primer set of each Taenia species separately, which is complex and time consuming and increases the risk of cross-contamination. In this study, we developed a simple differential identification of human Taenia species using multiplex LAMP (mLAMP) in combination with dot enzyme-linked immunosorbent assay (dot-ELISA). Forward inner primers of T. solium, T. saginata, and T. asiatica labeled with fluorescein isothiocyanate (FITC), digoxigenin (DIG), and tetramethylrhodamine (TAMRA), respectively, and biotin-labeled backward inner primers were used in mLAMP. The mLAMP assay succeeded in specific amplification of each respective target gene in a single tube. Furthermore, the mLAMP product from each species was easily distinguished by dot-ELISA with an antibody specific for FITC, DIG, or TAMRA. The mLAMP assay in combination with dot-ELISA will make identification of human Taenia species simpler, easier, and more practical. PMID:27044566

  16. An integrated target sequence and signal amplification assay, reverse transcriptase-PCR-enzyme-linked immunosorbent assay, to detect and characterize flaviviruses.

    PubMed Central

    Chang, G J; Trent, D W; Vorndam, A V; Vergne, E; Kinney, R M; Mitchell, C J

    1994-01-01

    We previously described a reverse transcriptase-PCR using flavivirus genus-conserved and virus species-specific amplimers (D. W. Trent and G. J. Chang, p. 355-371, in Y. Becker and C. Darai; ed., Frontiers of Virology, vol. 1, 1992). Target amplification was improved by redesigning the amplimers, and a sensitive enzyme-linked immunosorbent assay (ELISA) technique has been developed to detect amplified digoxigenin (DIG)-modified DNA. A single biotin motif and multiple DIG motifs were incorporated into each amplicon, which permitted amplicon capture by a biotin-streptavidin interaction and detection with DIG-specific antiserum in a colorimetric ELISA. We evaluated the utility of this assay for detecting St. Louis encephalitis (SLE) viral RNA in infected mosquitoes and dengue viral RNA in human serum specimens. The reverse transcriptase-PCR-ELISA was as sensitive as isolation of SLE virus by cell culture in detecting SLE viral RNA in infected mosquitoes. The test was 89% specific and 95 to 100% sensitive for identification of dengue viral RNA in serum specimens compared with isolation of virus by Aedes albopictus C6/36 cell culture and identification by the indirect immunofluorescence assay. PMID:7512096

  17. An integrated target sequence and signal amplification assay, reverse transcriptase-PCR-enzyme-linked immunosorbent assay, to detect and characterize flaviviruses.

    PubMed

    Chang, G J; Trent, D W; Vorndam, A V; Vergne, E; Kinney, R M; Mitchell, C J

    1994-02-01

    We previously described a reverse transcriptase-PCR using flavivirus genus-conserved and virus species-specific amplimers (D. W. Trent and G. J. Chang, p. 355-371, in Y. Becker and C. Darai; ed., Frontiers of Virology, vol. 1, 1992). Target amplification was improved by redesigning the amplimers, and a sensitive enzyme-linked immunosorbent assay (ELISA) technique has been developed to detect amplified digoxigenin (DIG)-modified DNA. A single biotin motif and multiple DIG motifs were incorporated into each amplicon, which permitted amplicon capture by a biotin-streptavidin interaction and detection with DIG-specific antiserum in a colorimetric ELISA. We evaluated the utility of this assay for detecting St. Louis encephalitis (SLE) viral RNA in infected mosquitoes and dengue viral RNA in human serum specimens. The reverse transcriptase-PCR-ELISA was as sensitive as isolation of SLE virus by cell culture in detecting SLE viral RNA in infected mosquitoes. The test was 89% specific and 95 to 100% sensitive for identification of dengue viral RNA in serum specimens compared with isolation of virus by Aedes albopictus C6/36 cell culture and identification by the indirect immunofluorescence assay.

  18. Computer-assisted enzyme immunoassays and simplified immunofluorescence assays: applications for the diagnostic laboratory and the veterinarian's office.

    PubMed

    Jacobson, R H; Downing, D R; Lynch, T J

    1982-11-15

    A computer-assisted enzyme-linked immunosorbent assay (ELISA) system, based on kinetics of the reaction between substrate and enzyme molecules, was developed for testing large numbers of sera in laboratory applications. Systematic and random errors associated with conventional ELISA technique were identified leading to results formulated on a statistically validated, objective, and standardized basis. In a parallel development, an inexpensive system for field and veterinary office applications contained many of the qualities of the computer-assisted ELISA. This system uses a fluorogenic indicator (rather than the enzyme-substrate interaction) in a rapid test (15 to 20 minutes' duration) which promises broad application in serodiagnosis.

  19. Immunochromatographic assay using gold nanoparticles for measuring salivary secretory IgA in dogs as a stress marker

    NASA Astrophysics Data System (ADS)

    Takahashi, Aki; Uchiyama, Shigeru; Kato, Yuya; Yuhi, Teruko; Ushijima, Hiromi; Takezaki, Makoto; Tominaga, Toshihiro; Moriyama, Yoshiko; Takeda, Kunio; Miyahara, Toshiro; Nagatani, Naoki

    2009-06-01

    The concentration of salivary secretory immunoglobulin A (sIgA) is a well-known stress marker for humans. The concentration of salivary sIgA in dogs has also been reported as a useful stress marker. In addition, salivary sIgA in dogs has been used to determine the adaptive ability of dogs for further training. There are conventional procedures based on enzyme-linked immunosorbent assay (ELISA) for measuring salivary sIgA in dogs. However, ELISA requires long assay time, complicated operations and is costly. In the present study, we developed an immunochromatographic assay for measuring salivary sIgA in dogs using a dilution buffer containing a non-ionic surfactant. We determined 2500-fold dilution as the optimum condition for dog saliva using a phosphate buffer (50 mM, pH 7.2) containing non-ionic surfactant (3 wt% Tween 20). The results obtained from the saliva samples of three dogs using immunochromatographic assay were compared with those obtained from ELISA. It was found that the immunochromatographic assay is applicable to judge the change in salivary sIgA in each dog. The immunochromatographic assay for salivary sIgA in dogs is a promising tool, which should soon become commercially available for predicting a dog's psychological condition and estimating adaptive ability for training as guide or police dogs.

  20. Assay optimisation and technology transfer for multi-site immuno-monitoring in vaccine trials

    PubMed Central

    Harris, Stephanie A.; Satti, Iman; Bryan, Donna; Walker, K. Barry; Dockrell, Hazel M.; McShane, Helen; Ho, Mei Mei

    2017-01-01

    Cellular immunological assays are important tools for the monitoring of responses to T-cell-inducing vaccine candidates. As these bioassays are often technically complex and require considerable experience, careful technology transfer between laboratories is critical if high quality, reproducible data that allows comparison between sites, is to be generated. The aim of this study, funded by the European Union Framework Program 7-funded TRANSVAC project, was to optimise Standard Operating Procedures and the technology transfer process to maximise the reproducibility of three bioassays for interferon-gamma responses: enzyme-linked immunosorbent assay (ELISA), ex-vivo enzyme-linked immunospot and intracellular cytokine staining. We found that the initial variability in results generated across three different laboratories reduced following a combination of Standard Operating Procedure harmonisation and the undertaking of side-by-side training sessions in which assay operators performed each assay in the presence of an assay ‘lead’ operator. Mean inter-site coefficients of variance reduced following this training session when compared with the pre-training values, most notably for the ELISA assay. There was a trend for increased inter-site variability at lower response magnitudes for the ELISA and intracellular cytokine staining assays. In conclusion, we recommend that on-site operator training is an essential component of the assay technology transfer process and combined with harmonised Standard Operating Procedures will improve the quality, reproducibility and comparability of data produced across different laboratories. These data may be helpful in ongoing discussions of the potential risk/benefit of centralised immunological assay strategies for large clinical trials versus decentralised units. PMID:29020010

  1. Dual function of the hemagglutinin H5 fused to chicken CD154 in a potential strategy of DIVA against avian influenza disease: preliminary study.

    PubMed

    Pose, A G; Rodríguez, E S; Méndez, A C; Gómez, J N; Redondo, A V; Rodríguez, E R; Ramos, E M G; Gutiérrez, A Á; Moltó, M P R; Roche, D G; Ugalde, Y S; López, A M

    2015-01-01

    In this study we demonstrated that the vaccine candidate against avian influenza virus H5N1 based on the hemagglutinin H5 (HA) fused to the chicken CD154 (HACD) can also be used for differentiating infected from vaccinated animals (DIVA). As the strategy of DIVA requires at least two proteins, we obtained a variant of the nucleoprotein (NP49-375) in E. coli. After its purification by IMAC, the competence of the proteins NP49-375 and HACD as coating antigens in indirect ELISA assays were tested by using the sera of chickens immunized with the proteins HA and HACD and the reference sera from several avian influenza subtypes. Together with these sera, the sera from different species of birds and the sera of chickens infected with other avian viral diseases were analyzed by competition ELISA assays coated with the proteins NP49-375 and HACD. The results showed that the segment CD154 in the chimeric protein HACD did not interfere with the recognition of the molecule HA by its specific antibodies. Also, we observed variable detection levels when the reference sera were analyzed in the ELISA plates coated with the protein NP49-375. Moreover, only the antibodies of the reference serum subtype H5 were detected in the ELISA plates coated with the protein HACD. The competition ELISA assays showed percentages of inhibition of 88-91% for the positives sera and less than 20% for the negative sera. We fixed the cut-off value of these assays at 25%. No antibody detection was observed in the sera from different species of birds or the sera of chickens infected with other avian viral diseases. This study supported the fact that the ELISA assays using the proteins NP49-375 and HACD could be valuable tools for avian influenza surveillance and as a strategy of DIVA for counteracting the highly pathogenic avian influenza virus H5N1 outbreaks.

  2. Comparative analysis of toxin detection in biological and enviromental samples

    NASA Astrophysics Data System (ADS)

    Ogert, Robert A.; Burans, James; O'Brien, Tom; Ligler, Frances S.

    1994-03-01

    The basic recognition schemes underlying the principles of standard enzyme-linked immunosorbent assay (ELISA) and radioimmunoassay (RIA) protocols are increasingly being adapted for use with new detection devices. A direct comparison was made using a fiber optic biosensor that employs evanescent wave detection and an ELISA using avidin-biotin. The assays were developed for the detection of Ricinus communis agglutinin II, also known as ricin or RCA60. Detection limits between the two methods were comparable for ricin in phosphate buffered saline (PBS), however results in complex samples differed slightly. In PBS, sensitivity for ricin was 1 ng/ml using the fiber optic device and 500 pg/ml using the ELISA. The fiber optic sensor could not detect ricin directly in urine or serum spiked with 5 ng/ml ricin, however, the ELISA showed detection but at reduced levels to the PBS control.

  3. Evaluation of a Commercial Sandwich Enzyme-Linked Immunosorbent Assay for the Quantification of Beta-Casomorphin 7 in Yogurt Using Solid-Phase Extraction Coupled to Liquid Chromatography-Tandem Mass Spectrometry as the "Gold Standard" Method.

    PubMed

    Nguyen, Duc Doan; Busetti, Francesco; Johnson, Stuart Keith; Solah, Vicky Ann

    2018-03-01

    This study investigated beta-casomorphin 7 (BCM7) in yogurt by means of LC-tandem MS (MS/MS) and enzyme-linked immunosorbent assay (ELISA) and use LC-MS/MS as the "gold standard" method to evaluate the applicability of a commercial ELISA. The level of BCM7 in milk obtained from ELISA analysis was much lower than that obtained by LC-MS/MS analysis and trended to increase during fermentation and storage of yogurt. Meanwhile, the results obtained from LC-MS/MS showed that BCM7 degraded during stages of yogurt processing, and its degradation may have been caused by X-prolyl dipeptidyl aminopeptidase activity. As a result, the commercial sandwich ELISA kit was not suitable for the quantification of BCM7 in fermented dairy milk.

  4. Citrullinated Chemokines in Rheumatoid Arthritis

    DTIC Science & Technology

    2016-12-01

    immunosorbent assay ( ELISA ) in RA and normal (NL) sera and in RA, osteoarthritis (OA), and other inflammatory rheumatic disease (OD) synovial fluids (SFs... ELISA ) Epithelial Neutrophil Chemoattractant Peptide-78 (ENA-78/CXCL5) Monocyte Chemoattractant Protein-1 (MCP-1/CCL2) Macrophage Inflammatory...Citrullinated chemokines are highly expressed in RA sera and SFs. Citrullinated chemokines were measured using an ELISA in which chemokines were captured on

  5. Effects of Early Altitude Exposure Following Traumatic Injury and Hemorrhagic Shock

    DTIC Science & Technology

    2017-06-27

    chemokines by multiplex enzyme-linked immunosorbent assay ( ELISA ) (Quansys, Logan, UT), including the following: interleukin 1 alpha and beta (IL...Tissue Cytokine Profiles Fourteen cytokines and chemokines were analyzed from serum and intestinal tissues via multiplex ELISA . There were no...2017-3567, 25 Jul 2017. LIST OF ABBREVIATIONS AND ACRONYMS AE aeromedical evacuation BCA bicinchoninic acid ELISA enzyme-linked immunosorbent

  6. 9 CFR 85.6 - Interstate movement of pseudorabies vaccinate swine, except swine from qualified negative gene...

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... enzyme-linked immunosorbent assay (ELISA) or a gpI Particle Concentration Fluorescence Immunoassay (PCFIA... negative; (iv) The date of the gpI ELISA or the gpI PCFIA approved differential pseudorabies test; and (v) The name of the laboratory that conducted the gpI ELISA or the gpI PCFIA approved differential...

  7. 9 CFR 85.6 - Interstate movement of pseudorabies vaccinate swine, except swine from qualified negative gene...

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... enzyme-linked immunosorbent assay (ELISA) or a gpI Particle Concentration Fluorescence Immunoassay (PCFIA... negative; (iv) The date of the gpI ELISA or the gpI PCFIA approved differential pseudorabies test; and (v) The name of the laboratory that conducted the gpI ELISA or the gpI PCFIA approved differential...

  8. 9 CFR 85.6 - Interstate movement of pseudorabies vaccinate swine, except swine from qualified negative gene...

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... enzyme-linked immunosorbent assay (ELISA) or a gpI Particle Concentration Fluorescence Immunoassay (PCFIA... negative; (iv) The date of the gpI ELISA or the gpI PCFIA approved differential pseudorabies test; and (v) The name of the laboratory that conducted the gpI ELISA or the gpI PCFIA approved differential...

  9. 9 CFR 85.6 - Interstate movement of pseudorabies vaccinate swine, except swine from qualified negative gene...

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... enzyme-linked immunosorbent assay (ELISA) or a gpI Particle Concentration Fluorescence Immunoassay (PCFIA... negative; (iv) The date of the gpI ELISA or the gpI PCFIA approved differential pseudorabies test; and (v) The name of the laboratory that conducted the gpI ELISA or the gpI PCFIA approved differential...

  10. 9 CFR 85.6 - Interstate movement of pseudorabies vaccinate swine, except swine from qualified negative gene...

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... enzyme-linked immunosorbent assay (ELISA) or a gpI Particle Concentration Fluorescence Immunoassay (PCFIA... negative; (iv) The date of the gpI ELISA or the gpI PCFIA approved differential pseudorabies test; and (v) The name of the laboratory that conducted the gpI ELISA or the gpI PCFIA approved differential...

  11. Rapid screening of toxigenic vibrio cholerae O1 strains from south Iran by PCR-ELISA.

    PubMed

    Mousavi, Seyed Latif; Nazarian, Shahram; Amani, Jafar; Rahgerdi, Ahmad Karimi

    2008-01-01

    The ability to sensitively detect Vibrio cholera with PCR-ELISA method represents a considerable advancement over alternative more time-consuming methods for detection of this pathogen. The aim of this research is to evaluate the suitability of a PCR-enzyme-linked immunosorbent assay for sensitive and rapid detection of V. cholera O1. The 398-bp sequence of a gene that codes for the cholera toxin B subunit was amplified by PCR. The digoxigenin-labeled amplified products were coated on microplates and detected by ELISA. The PCR product was also hybridized with biotin labelled probe and detected by ELISA using streptavidin. The specificity of the PCR was determined using 10 bacterial strains and 50 samples from south Iran. The detection limit was 0.5 pg of the genomic DNA and five bacterial cells. Adaptation of PCR into PCR-ELISA assay format facilitates specific and sensitive detection and diagnosis of human cholera disease. We conclude that this PCR-ELISA is a diagnostic method that specifically detects toxin genes in V. cholera O1 strains. It is more rapid and less cumbersome than other diagnostic methods for detection of toxicity in these strains.

  12. Detection of Plasmodium Aldolase Using a Smartphone and Microfluidic Enzyme Linked Immunosorbent Assay

    PubMed Central

    2017-01-01

    Background Malaria control efforts are limited in rural areas. A low-cost system to monitor response without the use of electricity is needed. Plasmodium aldolase is a malaria biomarker measured using enzyme linked immunosorbent assay (ELISA) techniques. A three-part system using ELISA was developed consisting of a microfluidic chip, hand crank centrifuge, and a smartphone. Methods A circular microfluidic chip was fabricated using clear acrylic and a CO2 laser. A series of passive valves released reagents at precise times based upon centrifugal force. Color change was measured via smartphone camera using an application programmed in Java. The microchip was compared to a standard 96-well sandwich ELISA. Results Results from standard ELISA were compared to microchip at varying concentrations (1–10 ng/mL). Over 15 different microfluidic patterns were tested, and a final prototype of the chip was created. The prototype microchip was compared to standard sandwich ELISA (n = 20) using samples of recombinant aldolase. Color readings of standard ELISA and microfluidic microchip showed similar results. Conclusion A low-cost microfluidic system could detect and follow therapeutic outcomes in rural areas and identify resistant strains. PMID:29057138

  13. Preparation and Characteristic of Dextran-BSA Antibody and Establishment of its ELISA Immunoassay.

    PubMed

    Xie, Zhen-ming; Yu, Lin; Fang, Li-sha

    2015-01-01

    The enzyme-linked immunosorbent assay (ELISA) is a potential tool for the determination of dextran. In this study, dextran neoglycoprotein antigens were prepared by Reductive Amination method, and were confirmed by SDS-PAGE and free amino detection. The impact factors such as different oxidation degree of dextran, the conjugate reaction time to BSA were investigated. The best preparation conditions were obtained (n(dextran)/n(oxidant) of NaIO4 = 1/120, the reaction time of 24 h), and the antigen with best combination with standard was obtained. The antigens interacted with standard antibody and were evaluated through ELISA. The immunogen was immunized with white rabbits to obtained antibody, respectively. A general and broad class-specific ELISA immunoassay was developed for dextran detection according to ELISA theory. The optimized conditions of assay used coating antigen at 10 μg/mL, reaction time of antibody and rabbit-anti-bovine IgG in 45 min, blocking reagents with 5% calf serum. The developed ELISA detection method with good linear and accuracy was put to use for quantitative analysis of dextran T40 in commercial sugarpractical for detection of dextran.

  14. Enzyme-linked immunosorbent assay for Potomac horse fever disease.

    PubMed

    Pretzman, C I; Rikihisa, Y; Ralph, D; Gordon, J C; Bech-Nielsen, S

    1987-01-01

    An enzyme-linked immunosorbent assay (ELISA) for immunoglobulin G (IgG) and IgM in natural and experimental infections of equids with Ehrlichia risticii was developed. Ehrlichial organisms purified from an infected mouse macrophage cell line were used as the antigen. IgM was separated from serum IgG by the expedient of spun-column chromatography, allowing the use of an indirect ELISA for quantitation of both IgG and IgM in the test sera. Among 16 paired sera from horses exhibiting clinical signs of Potomac horse fever, 8 were positive by the indirect fluorescent-antibody test (IFA), 11 were positive by the IgG ELISA, and 8 were positive by the IgM ELISA. All IFA-positive specimens were positive by the IgG ELISA, which appeared to be more sensitive than the IFA. In all cases, the IgG ELISA alone would have sufficed for diagnosis when acute- and convalescent-phase sera were available. When 26 single acute- or convalescent-phase serum samples were tested, the IFA detected 8, the IgG ELISA detected 10, and the IgM ELISA detected 6 positive serum specimens. The kinetics of IgG and IgM responses as determined by ELISA in two experimentally infected ponies which survived infection and challenges revealed that specific IgM was short-lived, falling to undetectable levels by day 60 postinoculation, whereas specific IgG persisted for more than 1 year. IgM and IgG were detected as early as days 1 and 10, respectively, postinoculation. The results suggest that the ELISA is more sensitive than the IFA and that the IgM ELISA may provide a means for early diagnosis of Potomac horse fever at or before the onset of clinical signs.

  15. Reverse enzyme-linked immunosorbent assay using monoclonal antibodies against SAG1-related sequence, SAG2A, and p97 antigens from Toxoplasma gondii to detect specific immunoglobulin G (IgG), IgM, and IgA antibodies in human sera.

    PubMed

    Carvalho, Fernando R; Silva, Deise A O; Cunha-Júnior, Jair P; Souza, Maria A; Oliveira, Taísa C; Béla, Samantha R; Faria, Gabriele G; Lopes, Carolina S; Mineo, José R

    2008-08-01

    The present study aimed to evaluate the performance of three monoclonal antibodies (MAbs) in reverse enzyme-linked immunosorbent assays (ELISAs) for detecting immunoglobulin G (IgG), IgM, and IgA antibodies against Toxoplasma gondii in 175 serum samples from patients at different stages of T. gondii infection, as defined by both serological and clinical criteria, as follows: recent (n = 45), transient (n = 40), and chronic (n = 55) infection as well as seronegative subjects (n = 35). The results were compared with those obtained by indirect ELISA using soluble Toxoplasma total antigen (STAg). Our data demonstrated that MAb A3A4 recognizes a conformational epitope in SAG1-related-sequence (SRS) antigens, while A4D12 and 1B8 recognize linear epitopes defined as SAG2A surface antigen and p97 cytoplasmatic antigen, respectively. Reverse ELISA for IgG with A3A4 or A4D12 MAbs was highly correlated with indirect ELISA for anti-STAg IgG, whereas only A4D12 reverse ELISA showed high correlation with indirect ELISA for IgM and IgA isotypes. To our knowledge, this is the first report analyzing the performance of a reverse ELISA for simultaneous detection of IgG, IgM, and IgA isotypes active toward native SAG2A, SRS, and p97 molecules from STAg, using a panel of human sera from patients with recent and chronic toxoplasmosis. Thus, reverse ELISA based on the capture of native SAG2A and SRS antigens of STAg by MAbs could be an additional approach for strengthening the helpfulness of serological tests assessing the stage of infection, particularly in combination with highly sensitive and specific assays that are frequently used nowadays for diagnosis of toxoplasmosis during pregnancy or congenital infection in newborns.

  16. Comparison of in-house biotin-avidin tetanus IgG enzyme-linked-immunosorbent assay (ELISA) with gold standard in vivo mouse neutralization test for the detection of low level antibodies.

    PubMed

    Sonmez, Cemile; Coplu, Nilay; Gozalan, Aysegul; Akin, Lutfu; Esen, Berrin

    2017-06-01

    Detection of anti-tetanus antibody levels is necessary for both determination of the immune status of individuals and also for planning preventive measures. ELISA is the preferred test among in vitro tests however it can be affected by the cross reacting antibodies. A previously developed in-house ELISA test was found not reliable for the antibody levels ≤1.0IU/ml. A new method was developed to detect low antibody levels correctly. The aim of the present study was to compare the results of the newly developed in-house biotin-avidin tetanus IgG ELISA test with the in vivo mouse neutralization test, for the antibody levels ≤1.0IU/ml. A total of 54 serum samples with the antibody levels of three different levels, =0.01IU/ml, 0.01-0.1IU/ml, 0.1-1IU/ml, which were detected by in vivo mouse neutralization test were studied by the newly developed in-house biotin-avidin tetanus IgG ELISA test. Test was validated by using five different concentrations (0.01IU/ml, 0.06IU/ml, 0.2IU/ml, 0.5IU/ml, 1.0IU/ml). A statistically significant correlation (r 2 =0.9967 p=0,001) between in vivo mouse neutralization test and in-house biotin-avidin tetanus IgG ELISA test, was observed. For the tested concentrations intra-assay, inter-assay, accuracy, sensitivity, specificity and coefficients of variations were determined as ≤15%. In-house biotin-avidin tetanus IgG ELISA test can be an alternative method to in vivo mouse neutralization method for the detection of levels ≤1.0IU/ml. By using in-house biotin-avidin tetanus IgG ELISA test, individuals with non protective levels, will be reliably detected. Copyright © 2017. Published by Elsevier B.V.

  17. Diagnostic accuracy of the anti-glutamic acid decarboxylase antibody in type 1 diabetes mellitus: Comparison between radioimmunoassay and enzyme-linked immunosorbent assay.

    PubMed

    Murata, Takashi; Tsuzaki, Kokoro; Nirengi, Shinsuke; Watanabe, Tomokazu; Mizutani, Yukako; Okada, Hayami; Tsukamoto, Masami; Odori, Shinji; Nakagawachi, Reiko; Kawaguchi, Yaeko; Yoshioka, Fumi; Yamada, Kazunori; Shimatsu, Akira; Kotani, Kazuhiko; Satoh-Asahara, Noriko; Sakane, Naoki

    2017-07-01

    The distributer of the anti-glutamic acid decarboxylase antibody assay kit using radioimmunoassay (RIA) recently announced its discontinuation, and proposed an alternative kit using enzyme-linked immunosorbent assay (ELISA). The aim of the present study was to investigate the diagnostic values of the anti-glutamic acid decarboxylase antibody by RIA and ELISA among type 1 diabetes mellitus patients and control participants. A total of 79 type 1 diabetes mellitus patients and 79 age-matched controls were enrolled and assessed using RIA and ELISA. Sensitivity, specificity, positive predictive values and negative predictive values were calculated for cut-off values (RIA = 1.5 U/mL and ELISA = 5.0 U/mL, respectively). Kappa coefficients were used to test for agreements between the RIA and ELISA methods regarding the diagnosis of type 1 diabetes mellitus. The sensitivity, specificity, positive predictive values, and negative predictive values for diagnosing type 1 diabetes mellitus were 57.0, 97.5, 95.7, and 69.4% by RIA, and 60.8, 100.0, 100.0 and 71.8% by ELISA, respectively. The diagnosis of type 1 diabetes mellitus using the RIA and ELISA methods showed substantial agreement with the kappa values of 0.74 for all participants, and of 0.64 for the acute type; however, there was moderate agreement with the kappa value of 0.56 for the slowly progressive type. The present study suggests that both anti-glutamic acid decarboxylase antibody by RIA and ELISA was useful for diagnosing type 1 diabetes mellitus. However, in the slowly progressive type, the degree of agreement of these two kits was poorer compared with those in all participants or in the acute type. © 2016 The Authors. Journal of Diabetes Investigation published by Asian Association for the Study of Diabetes (AASD) and John Wiley & Sons Australia, Ltd.

  18. Serodiagnosis of sporotrichosis infection in cats by enzyme-linked immunosorbent assay using a specific antigen, SsCBF, and crude exoantigens.

    PubMed

    Fernandes, Geisa Ferreira; Lopes-Bezerra, Leila Maria; Bernardes-Engemann, Andréa Reis; Schubach, Tânia Maria Pacheco; Dias, Maria Adelaide Galvão; Pereira, Sandro Antonio; de Camargo, Zoilo Pires

    2011-01-27

    The main objective of this study is to standardize an ELISA for the diagnosis of feline sporotrichosis. Sporothrix schenckii is the etiological agent of human and animal sporotrichosis. Cats may act as reservoirs for S. schenckii and can transmit the infection to humans by a bite or scratch. There are few methods for the serological diagnosis of fungal diseases in animals. In this paper, an ELISA test for the diagnosis of cat sporotrichosis is proposed, which detects S. schenckii-specific antibodies in feline sera. Two different kinds of antigens were used: "SsCBF", a specific molecule from S. schenckii that consists of a Con A-binding fraction derived from a peptido-rhamnomannan component of the cell wall, and a S. schenckii crude exoantigen preparation. The ELISA was developed, optimized, and evaluated using sera from 30 cats with proven sporotrichosis (by culture isolation); 22 sera from healthy feral cats from a zoonosis center were used as negative controls. SsCBF showed 90% sensitivity and 96% specificity in ELISA; while crude exoantigens demonstrated 96% sensitivity and 98% specificity. The ELISA assay described here would be a valuable screening tool for the detection of specific S. schenckii antibodies in cats with sporotrichosis. The assay is inexpensive, quick to perform, easy to interpret, and permits the diagnosis of feline sporotrichosis. Copyright © 2010 Elsevier B.V. All rights reserved.

  19. Testing for Soluble ST2 in Heart Failure Patients: Reliability of a Point of Care Method.

    PubMed

    Gruson, Damien; Ferracin, Benjamin; Ahn, Sylvie A; Rousseau, Michel F

    2017-01-01

    Our objective was to determine soluble ST2 (sST2) concentrations in heart failure (HF) patients with a point-of-care (POCT) assay. sST2 levels were measured in 71 HF patients with both POCT and ELISA methods. The concentrations of sST2 were correlated to HF severity and to some established biomarkers of cardiovascular risk. sST2 levels measured with the ASPECT-PLUS POCT method were significantly correlated with the comparison ELISA assay (r = 0.94, p < 0.01) and were related to HF severity. Levels of sST2 measured with the POCT assay were significantly correlated to NT-proBNP (r = 0.57, p < 0.001), BNP (r = 0.75, p < 0.001), Galectin-3 (r = 0.40, p < 0.01) and PTH (1-84) (r = 0.39, p < 0.01). POCT and ELISA methods for sST2 testing were significantly correlated, and our results confirmed also the clinical reliability of the sST2 POCT assay. Furthermore, the POCT method allows a faster delivery of results to physicians.

  20. Biotin-streptavidin enzyme-linked immunosorbent assay for detecting Tetrabromobisphenol A in electronic waste.

    PubMed

    Bu, Dan; Zhuang, Huisheng; Zhou, Xinchu; Yang, Guangxin

    2014-03-01

    Tetrabromobisphenol A (TBBPA) is a widely used brominated flame retardant. A sensitive and selective indirect competitive biotin-streptavidin-amplified enzyme-linked immunosorbent assay (BA-ELISA) was developed for detecting TBBPA. The optimal hapten of TBBPA was 2-(2,6-dibromo-4-(2-(3,5-dibromo-4-hydroxyphenly)propan-2-yl)) acetic acid. Several physiochemical factors that influence assay performance, such as optimal coupling concentration of immunogen and antibody, organic solvent, ionic strength, and pH, were studied and optimized. The limit of detection (IC10) was 0.027 ng/mL and the median inhibitory concentration (IC50) was 0.58 ng/mL. The BA-ELISA was highly selective, with low cross-reactivity with TBBPA analogs. Finally, the assay was used to detect TBBPA in electronic waste samples. The results are consistent with those using liquid chromatography, which proves that the proposed immunoassay is accurate and receptive. This BA-ELISA method is suitable for the rapid and sensitive screening of TBBPA in environmental monitoring. © 2013 Published by Elsevier B.V.

  1. An ELISA method detecting the active form of suPAR.

    PubMed

    Zhou, Xiaolei; Xu, Mingming; Huang, Hailong; Mazar, Andrew; Iqbal, Zafar; Yuan, Cai; Huang, Mingdong

    2016-11-01

    Urokinase plasminogen activator receptor (uPAR) exists in a number of formats in human plasma, including soluble uPAR (suPAR) and uPAR fragments. We developed an ELISA method to detect specifically the active form suPAR, which binds to its natural ligand uPA. The intra CV and inter CV of this ELISA assay is 8.5% and 9.6% respectively, and the assay can recover 99.74% of added recombinant suPAR from 10% plasma. This assay is quite sensitive, capable of detecting down to 15pg/ml of suPAR, and can measure suPAR concentrations in the range of 0.031-8ng/ml with high linear relationship. Plasma samples from pregnant women were also measured for the active form of suPAR with this assay, giving an averaged level of 1.39ng/ml, slightly higher than the level of pooled plasma from healthy donors (0.96ng/ml). This study demonstrates the feasibility to measure the active form of suPAR, which will likely have value in clinical applications. Copyright © 2016. Published by Elsevier B.V.

  2. Microbubble Enzyme-Linked Immunosorbent Assay for the Detection of Targeted Microbubbles in in Vitro Static Binding Assays.

    PubMed

    Wischhusen, Jennifer; Padilla, Frederic

    2017-07-01

    Targeted microbubbles (MBs) are ultrasound contrast agents that are functionalized with a ligand for ultrasound molecular imaging of endothelial markers. Novel targeted MBs are characterized in vitro by incubation in protein-coated wells, followed by binding quantification by microscopy or ultrasound imaging. Both methods provide operator-dependent results: Between 3 and 20 fields of view from a heterogeneous sample are typically selected for analysis by microscopy, and in ultrasound imaging, different acoustic settings affect signal intensities. This study proposes a new method to reproducibly quantify MB binding based on enzyme-linked immunosorbent assay (ELISA), in which bound MBs are revealed with an enzyme-linked antibody. MB-ELISA was adapted to in vitro static binding assays, incubating the MBs in inverted position or by agitation, and compared with microscopy. The specificity and sensitivity of MB-ELISA enable the reliable quantification of MB binding in a rapid, high-throughput and whole-well analysis, facilitating the characterization of new targeted contrast agents. Copyright © 2017 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  3. Absorption of p,p'-dichlorodiphenyldichloroethylene and dieldrin in largemouth bass from a 60-D slow-release pellet and detection using a novel enzyme-linked immunosorbent assay method for blood plasma

    USGS Publications Warehouse

    Muller, Jennifer K.; Sepulveda, Maria S.; Borgert, Christopher J.; Gross, Timothy S.

    2005-01-01

    This work describes the uptake of two organochlorine pesticides from slow-release pellets by largemouth bass and the utility of a blood plasma enzyme-linked immunosorbent assay (ELISA) method for exposure verification. We measured blood and tissue levels by gas chromatography/mass spectrometry and by a novel ELISA method, and present a critical comparison of the results.

  4. Development and evaluation of an avian influenza, neuraminidase subtype 1, indirect enzyme-linked immunosorbent assay for poultry using the differentiation of infected from vaccinated animals control strategy

    USDA-ARS?s Scientific Manuscript database

    An indirect ELISA was developed using baculovirus expressed N1 protein from the A/chicken/Indonesia/7/2003 (H5N1) virus. The specificity of the assay was tested with a panel of chicken antisera raised against N1 to N9 virus subtypes. The N1-ELISA was specific for the detection of N1 antibodies in ...

  5. Development of a Recombinant Protein-Based Enzyme-Linked Immunosorbent Assay for Diagnosis of Mycoplasma bovis Infection in Cattle

    PubMed Central

    Wawegama, Nadeeka K.; Kanci, Anna; Marenda, Marc S.; Markham, Philip F.

    2014-01-01

    Mycoplasma bovis causes a range of diseases in cattle, including mastitis, arthritis, and pneumonia. However, accurate serological diagnosis of infection remains problematic. The studies described here aimed to identify an antigen that might be used to develop a more specific and sensitive diagnostic assay. A 226-kDa immunogenic protein was consistently detected in Western blots by antibodies in sera from calves experimentally infected with M. bovis. This protein was shown to be a membrane protein with lipase activity and was named mycoplasma immunogenic lipase A (MilA). Different regions of MilA were expressed in Escherichia coli as glutathione S-transferase (GST) fusion proteins and recombinant products from the amino-terminal end shown to have strong immunoreactivity with M. bovis-specific bovine sera. The most immunoreactive fusion protein, GST-MilA-ab, was used to develop indirect IgM and IgG enzyme-linked immunosorbent assays (ELISAs). The IgM ELISA detected M. bovis-specific IgM antibody 2 weeks after infection with 97.1% sensitivity and had a specificity of 63.3%, while the IgG ELISA detected M. bovis-specific IgG 3 weeks after infection with 92.86% sensitivity and had a specificity of 98.7%, demonstrating that the IgG ELISA has potential for use as a sensitive and specific assay for detecting infection in cattle. PMID:24334686

  6. A digital enzyme-linked immunosorbent assay for ultrasensitive measurement of amyloid-β 1-42 peptide in human plasma with utility for studies of Alzheimer's disease therapeutics.

    PubMed

    Song, Linan; Lachno, D Richard; Hanlon, David; Shepro, Adam; Jeromin, Andreas; Gemani, Dipika; Talbot, Jayne A; Racke, Margaret M; Dage, Jeffrey L; Dean, Robert A

    2016-12-15

    Amyloid-β 1-42 peptide (Aβ 1-42 ) is associated with plaque formation in the brain of patients with Alzheimer's disease (AD). Pharmacodynamic studies of AD therapeutics that lower the concentrations of Aβ 1-42 in peripheral blood require highly sensitive assays for its measurement. A digital enzyme-linked immunosorbent assay (ELISA) using single molecule array (Simoa) technology has been developed that provides improved sensitivity compared with conventional ELISA methods using the same antibody reagents. A sensitive digital ELISA for measurement of Aβ 1-42 using antibodies 3D6 and 21F12 was developed. Assay performance was evaluated by repeated testing of pooled human plasma and buffer diluent quality control samples to determine relative accuracy, intra- and inter-assay precision, limit of detection (LOD), lower limit of quantification (LLOQ), dilutional linearity, and spike recovery. The optimized assay was used to quantify Aβ 1-42 in clinical samples from patients treated with the β-site amyloid precursor protein cleaving enzyme 1 inhibitor LY2886721. The prototype assay measured Aβ 1-42 with an LOD of 0.3 pg/ml and an LLOQ of 2.8 pg/ml in plasma, calibrated using an Aβ 1-42 peptide standard from Fujirebio. Assay precision was acceptable with intra- and inter-assay coefficients of variation both being ≤10%. Dilutional linearity was demonstrated in sample diluent and immunodepleted human plasma. Analyte spike recovery ranged from 51% to 93% with a mean of 80%. This assay was able to quantify Aβ 1-42 in all of the 84 clinical samples tested. A rapid reduction in levels of Aβ 1-42 was detected within 1 h after drug treatment, and a dose-dependent decrease of Aβ 1-42 levels was also observed over the time course of sample collection. This digital ELISA has potential utility in clinical applications for quantification of Aβ 1-42 in plasma where high sensitivity and precision are required.

  7. Immunodiagnosis of Fasciola gigantica Infection Using Monoclonal Antibody-Based Sandwich ELISA and Immunochromatographic Assay for Detection of Circulating Cathepsin L1 Protease

    PubMed Central

    Anuracpreeda, Panat; Chawengkirttikul, Runglawan; Sobhon, Prasert

    2016-01-01

    Background Tropical fasciolosis caused by Fasciola gigantica infection is one of the major diseases infecting ruminants in the tropical regions of Africa and Asia including Thailand. Parasitological diagnosis of fasciolosis is often unreliable and possesses low sensitivity. Therefore, the detection of circulating parasite antigens is thought to be a better alternative for diagnosis of fasciolosis, as it reflects the real parasite burden. Methods In this study, we have produced a monoclonal antibody (MoAb) against recombinant F. gigantica cathepsin L1 (rFgCatL1), and developed both sandwich enzyme-linked immunosorbent assay (sandwich ELISA) and immunochromatographic (IC) test for rapid detection of circulating cathepsin L1 protease (CatL1) in the sera from mice experimentally and cattle naturally infected with Fasciola gigantica. MoAb 4E3 and biotinylated rabbit anti-recombinant CatL1 antibody were selected due to their high reactivities and specificities. Results The lower detection limits of sandwich ELISA and IC test were 3 pg/ml and 0.256 ng/ml, respectively. Sandwich ELISA and IC test could detect F. gigantica infection from day 1 to 35 post infection. In experimental mice, the sensitivity, specificity and accuracy were 95%, 100% and 98.6% (for sandwich ELISA), and 93%, 100% and 98.2% (for IC test), while in natural cattle they were 98.3%, 100% and 99.5% (for sandwich ELISA), and 96.7%, 100% and 99.1% (for IC test). Conclusions These two assay methods showed high efficiencies and precisions for diagnosis of fasciolosis by F. gigantica. PMID:26731402

  8. Immunodiagnosis of Fasciola gigantica Infection Using Monoclonal Antibody-Based Sandwich ELISA and Immunochromatographic Assay for Detection of Circulating Cathepsin L1 Protease.

    PubMed

    Anuracpreeda, Panat; Chawengkirttikul, Runglawan; Sobhon, Prasert

    2016-01-01

    Tropical fasciolosis caused by Fasciola gigantica infection is one of the major diseases infecting ruminants in the tropical regions of Africa and Asia including Thailand. Parasitological diagnosis of fasciolosis is often unreliable and possesses low sensitivity. Therefore, the detection of circulating parasite antigens is thought to be a better alternative for diagnosis of fasciolosis, as it reflects the real parasite burden. In this study, we have produced a monoclonal antibody (MoAb) against recombinant F. gigantica cathepsin L1 (rFgCatL1), and developed both sandwich enzyme-linked immunosorbent assay (sandwich ELISA) and immunochromatographic (IC) test for rapid detection of circulating cathepsin L1 protease (CatL1) in the sera from mice experimentally and cattle naturally infected with Fasciola gigantica. MoAb 4E3 and biotinylated rabbit anti-recombinant CatL1 antibody were selected due to their high reactivities and specificities. The lower detection limits of sandwich ELISA and IC test were 3 pg/ml and 0.256 ng/ml, respectively. Sandwich ELISA and IC test could detect F. gigantica infection from day 1 to 35 post infection. In experimental mice, the sensitivity, specificity and accuracy were 95%, 100% and 98.6% (for sandwich ELISA), and 93%, 100% and 98.2% (for IC test), while in natural cattle they were 98.3%, 100% and 99.5% (for sandwich ELISA), and 96.7%, 100% and 99.1% (for IC test). These two assay methods showed high efficiencies and precisions for diagnosis of fasciolosis by F. gigantica.

  9. Performance and diagnostic usefulness of commercially available enzyme linked immunosorbent assay and rapid kits for detection of HIV, HBV and HCV in India.

    PubMed

    Maity, Susmita; Nandi, Srijita; Biswas, Subrata; Sadhukhan, Salil Kumar; Saha, Malay Kumar

    2012-11-26

    HIV, HBV and HCV pose a major public health problem throughout the world. Detection of infection markers for these agents is a major challenge for testing laboratories in a resource poor setting. As blood transfusion is an important activity saving millions of live every year, it also carries a risk of transfusion transmissible infections caused by these fatal blood borne pathogens if the quality of testing is compromised. Conventional ELISA is regarded as the mostly used screening technique but due to limitations like high cost, unavailability in many blood banks and testing sites, involvement of costly instruments, time taking nature and requirement of highly skilled personnel for interpretation, rapid tests are gaining more importance and warrants comparison of performance. A comparative study between these two techniques has been performed using commercially available diagnostic kits to assess their efficacy for detection of HIV, HBV and HCV infections. Rapid kits were more efficient in specificity with synthetic antigens along with high PPV than ELISA in most cases. Comparison between different ELISA kits revealed that Microlisa HIV and Hepalisa (J. Mitra & Co. Pvt. Ltd.); ERBA LISA HIV1 + 2, ERBA LISA Hepatitis B and ERBA LISA HCV (Transasia Bio-medicals Ltd.) gives uniform result with good performance in terms of sensitivity, specificity, PPV, NPV and efficiency, whereas, Microlisa HCV (J. Mitra & Co. Pvt. Ltd.), Microscreen HBsAg ELISA and INNOVA HCV (Span Diagnostics Ltd.) did not perform well. Rapid kits were also having high degree of sensitivity and specificity (100%) except in HIV Comb and HCV Comb (J. Mitra & Co. Pvt. Ltd.). The kit efficiency didn't vary significantly among different companies and lots in all the cases except for HCV ELISA showing statistically significant variation (p < 0.01) among three kit types. ELISA is a good screening assay for markers of HIV, HBV and HCV infections. Rapid tests are useful for further detection of false positive samples. ELISA seems the appropriate assay in blood bank. For availability of quality commercial diagnostic assays, evaluation of kit may be helpful.

  10. Performance and diagnostic usefulness of commercially available enzyme linked immunosorbent assay and rapid kits for detection of HIV, HBV and HCV in India

    PubMed Central

    2012-01-01

    Background HIV, HBV and HCV pose a major public health problem throughout the world. Detection of infection markers for these agents is a major challenge for testing laboratories in a resource poor setting. As blood transfusion is an important activity saving millions of live every year, it also carries a risk of transfusion transmissible infections caused by these fatal blood borne pathogens if the quality of testing is compromised. Conventional ELISA is regarded as the mostly used screening technique but due to limitations like high cost, unavailability in many blood banks and testing sites, involvement of costly instruments, time taking nature and requirement of highly skilled personnel for interpretation, rapid tests are gaining more importance and warrants comparison of performance. Results A comparative study between these two techniques has been performed using commercially available diagnostic kits to assess their efficacy for detection of HIV, HBV and HCV infections. Rapid kits were more efficient in specificity with synthetic antigens along with high PPV than ELISA in most cases. Comparison between different ELISA kits revealed that Microlisa HIV and Hepalisa (J. Mitra & Co. Pvt. Ltd.); ERBA LISA HIV1 + 2, ERBA LISA Hepatitis B and ERBA LISA HCV (Transasia Bio-medicals Ltd.) gives uniform result with good performance in terms of sensitivity, specificity, PPV, NPV and efficiency, whereas, Microlisa HCV (J. Mitra & Co. Pvt. Ltd.), Microscreen HBsAg ELISA and INNOVA HCV (Span Diagnostics Ltd.) did not perform well. Rapid kits were also having high degree of sensitivity and specificity (100%) except in HIV Comb and HCV Comb (J. Mitra & Co. Pvt. Ltd.). The kit efficiency didn’t vary significantly among different companies and lots in all the cases except for HCV ELISA showing statistically significant variation (p < 0.01) among three kit types. Conclusions ELISA is a good screening assay for markers of HIV, HBV and HCV infections. Rapid tests are useful for further detection of false positive samples. ELISA seems the appropriate assay in blood bank. For availability of quality commercial diagnostic assays, evaluation of kit may be helpful. PMID:23181517

  11. A New Sandwich ELISA for Quantification of Thymidine Kinase 1 Protein Levels in Sera from Dogs with Different Malignancies Can Aid in Disease Management

    PubMed Central

    Jagarlamudi, Kiran Kumar; Moreau, Laura; Westberg, Sara; Rönnberg, Henrik; Eriksson, Staffan

    2015-01-01

    Thymidine kinase 1 (TK1) is a DNA precursor enzyme whose expression is closely correlated with cell proliferation and cell turnover. Sensitive serum TK1 activity assays have been used for monitoring and prognosis of hematological malignancies in both humans and dogs. Here we describe the development of a specific sandwich TK1-ELISA for the quantification of TK1 protein levels in sera from dogs with different malignancies. A combination of rabbit polyclonal anti-dog TK1 antibody and a mouse monoclonal anti-human TK1 antibody was used. Different concentrations of recombinant canine TK1 was used as standard. Clinical evaluation of the ELISA was done by using sera from 42 healthy dogs, 43 dogs with hematological tumors and 55 with solid tumors. An established [3H]-dThd phosphorylation assay was used to determine the TK1 activity levels in the same sera. The mean TK1 activities in dogs with hematological tumors were significantly higher than those found in healthy dogs. In agreement with earlier studies, no significant difference was observed in serum TK1 activities between healthy dogs and dogs with solid tumors. However, the mean TK1 protein levels determined by new TK1-ELISA were significantly higher not only in hematological tumors but also in solid tumors compared to healthy dogs (mean ± SD = 1.30 ± 1.16, 0.67 ± 0.55 and 0.27± 0.10 ng/mL, respectively). Moreover, TK1-ELISA had significantly higher ability to distinguish lymphoma cases from healthy based on receiver operating characteristic analyses (area under the curve, AUC, of 0.96) to that of the activity assay (AUC, 0.84). Furthermore, fluctuations in TK1 protein levels during the course of chemotherapy in dogs with lymphoma closely associated with clinical outcome. Overall, the TK1-ELISA showed significant linear correlation with the TK1 activity assay (r s = 0.6, p<0.0001). Thus, the new TK1-ELISA has sufficient sensitivity and specificity for routine clinical use in veterinary oncology. PMID:26366881

  12. A competitive ELISA to detect brevetoxins from Karenia brevis (formerly Gymnodinium breve) in seawater, shellfish, and mammalian body fluid.

    PubMed Central

    Naar, Jerome; Bourdelais, Andrea; Tomas, Carmelo; Kubanek, Julia; Whitney, Philip L; Flewelling, Leanne; Steidinger, Karen; Lancaster, Johnny; Baden, Daniel G

    2002-01-01

    We developed a competitive enzyme-linked immunosorbent assay (ELISA) to analyze brevetoxins, using goat anti-brevetoxin antibodies obtained after immunization with keyhole limpet hemocyanin-brevetoxin conjugates, in combination with a three-step signal amplification process. The procedure, which used secondary biotinylated antibodies, streptavidine-horseradish peroxidase conjugate, and chromogenic enzyme substrate, was useful in reducing nonspecific background signals commonly observed with complex matrices. This competitive ELISA detected brevetoxins in seawater, shellfish extract and homogenate, and mammalian body fluid such as urine and serum without pretreatment, dilution, or purification. We investigated the application of this technique for shellfish monitoring by spiking shellfish meat with brevetoxins and by analyzing oysters from two commercial shellfish beds in Florida that were exposed to a bloom of Karenia brevis (formerly Gymnodinium breve). We performed brevetoxin analysis of shellfish extracts and homogenates by ELISA and compared it with the mouse bioassay and receptor binding assay. The detection limit for brevetoxins in spiked oysters was 2.5 microg/100 g shellfish meat. This assay appears to be a useful tool for neurotoxic shellfish poisoning monitoring in shellfish and seawater, and for mammalian exposure diagnostics, and significantly reduces the time required for analyses. PMID:11836147

  13. Immunological detection of Fusarium species in cornmeal.

    PubMed

    Iyer, M S; Cousin, M A

    2003-03-01

    An indirect enzyme-linked immunosorbent assay (ELISA) was developed to detect Fusarium species in foods. Antibodies to proteins extracted from the mycelia of Fusarium graminearum and Fusarium moniliforme (verticillioides) were produced in New Zealand white rabbits. These antibodies detected 13 Fusarium species in addition to the producer strains. Levels of Fusarium semitectum and Fusarium tricinctum strains were below the detection threshold. The specificity of the assay was tested against 70 molds and yeasts belonging to 23 genera. One strain of Monascus species and one strain of Phoma exigua were detected; however, these two molds are not common contaminants of cereal grains or foods and should not interfere with the assay. The indirect ELISA's detection limits for F. graminearum and F. moniliforme were 0.1 and 1 microg of mold mycelium per ml of a cornmeal mixture, respectively. When spores of each mold were added individually to cornmeal mixtures (at ca. 10 spores per g) and incubated at 25 degrees C, these spores were detected by the indirect ELISA when they reached levels of 10(2) to 10(3) CFU/ml after 24 to 36 h. The indirect ELISA developed here shows promise for the detection of Fusarium species in grains or foods.

  14. Development and Evaluation of a Sensitive and Specific Assay for Diagnosis of Human Toxocariasis by Use of Three Recombinant Antigens (TES-26, TES-30USM, and TES-120)▿

    PubMed Central

    Mohamad, Suharni; Azmi, Norhaida Che; Noordin, Rahmah

    2009-01-01

    Diagnosis of human toxocariasis currently relies on serologic tests that use Toxocara excretory-secretory (TES) antigen to detect immunoglobulin G (IgG) antibodies to the larvae. In general, however, these assays do not have adequate specificity for use in countries in which other soil-transmitted helminths are endemic. The use of recombinant antigens in these assays, however, is promising for improving the specificity of the diagnosis of toxocariasis. Toward this goal, we developed an IgG4 enzyme-linked immunosorbent assay (ELISA) involving three recombinant antigens: rTES-30USM (previously produced), rTES-26, and rTES-120. The latter two antigens were produced by reverse transcription-PCR cloning; subcloned into glutathione S-transferase (GST)-tagged and His-tagged prokaryotic expression vectors, respectively; and expressed in Escherichia coli. The recombinant proteins were subsequently purified by affinity chromatography using GST and His-Trap resins. The diagnostic potential of each purified recombinant antigen was tested with various immunoglobulin classes (IgG, IgM, and IgE) and IgG subclasses. The IgG4 ELISA was determined to have the highest specificity and was further evaluated using a panel of serum samples. The rTES-26 IgG4 ELISA showed 80.0% (24/30 samples positive) sensitivity, and both the rTES-30USM IgG4 ELISA and rTES-120 IgG4 ELISA had 93.0% (28/30) sensitivity. Combined use of rTES-120 and rTES-30 IgG4 ELISA for the diagnosis of toxocariasis provided 100% sensitivity. The specificities of rTES-26, rTES-30USM, and rTES-120 antigens were 96.2%, 93.9%, and 92.0%, respectively. These results indicate that the development of a diagnostic test using the three recombinant antigens will allow for more-accurate detection of toxocariasis. PMID:19369434

  15. Development and evaluation of a sensitive and specific assay for diagnosis of human toxocariasis by use of three recombinant antigens (TES-26, TES-30USM, and TES-120).

    PubMed

    Mohamad, Suharni; Azmi, Norhaida Che; Noordin, Rahmah

    2009-06-01

    Diagnosis of human toxocariasis currently relies on serologic tests that use Toxocara excretory-secretory (TES) antigen to detect immunoglobulin G (IgG) antibodies to the larvae. In general, however, these assays do not have adequate specificity for use in countries in which other soil-transmitted helminths are endemic. The use of recombinant antigens in these assays, however, is promising for improving the specificity of the diagnosis of toxocariasis. Toward this goal, we developed an IgG4 enzyme-linked immunosorbent assay (ELISA) involving three recombinant antigens: rTES-30USM (previously produced), rTES-26, and rTES-120. The latter two antigens were produced by reverse transcription-PCR cloning; subcloned into glutathione S-transferase (GST)-tagged and His-tagged prokaryotic expression vectors, respectively; and expressed in Escherichia coli. The recombinant proteins were subsequently purified by affinity chromatography using GST and His-Trap resins. The diagnostic potential of each purified recombinant antigen was tested with various immunoglobulin classes (IgG, IgM, and IgE) and IgG subclasses. The IgG4 ELISA was determined to have the highest specificity and was further evaluated using a panel of serum samples. The rTES-26 IgG4 ELISA showed 80.0% (24/30 samples positive) sensitivity, and both the rTES-30USM IgG4 ELISA and rTES-120 IgG4 ELISA had 93.0% (28/30) sensitivity. Combined use of rTES-120 and rTES-30 IgG4 ELISA for the diagnosis of toxocariasis provided 100% sensitivity. The specificities of rTES-26, rTES-30USM, and rTES-120 antigens were 96.2%, 93.9%, and 92.0%, respectively. These results indicate that the development of a diagnostic test using the three recombinant antigens will allow for more-accurate detection of toxocariasis.

  16. Limits of diagnostic accuracy of anti-hepatitis C virus antibodies detection by ELISA and immunoblot assay.

    PubMed

    Suslov, Anatoly P; Kuzin, Stanislav N; Golosova, Tatiana V; Shalunova, Nina V; Malyshev, Nikolai A; Sadikova, Natalia V; Vavilova, Lubov M; Somova, Anna V; Musina, Elena E; Ivanova, Maria V; Kipor, Tatiana T; Timonin, Igor M; Kuzina, Lubov E; Godkov, Mihail A; Bajenov, Alexei I; Nesterenko, Vladimir G

    2002-07-01

    When human sera samples are tested for anti-hepatitis C virus (HCV) antibodies using different ELISA kits as well as immunoblot assay kits discrepant results often occur. As a result the diagnostics of HCV infection in such sera remains unclear. The purpose of this investigation is to define the limits of HCV serodiagnostics. Overall 7 different test kits of domestic and foreign manufacturers were used for the sampled sera testing. Preliminary comparative study, using seroconversion panels PHV905, PHV907, PHV908 was performed and reference kit was chosen (Murex anti-HCV version 4) as the most sensitive kit on the base of this study results. Overall 1640 sera samples have been screened using different anti-HCV ELISA kits and 667 of them gave discrepant results in at least two kits. These sera were then tested using three anti-HCV ELISA kits (first set of 377 samples) or four anti-HCV ELISA kits (second set of 290 samples) at the conditions of reference laboratory. In the first set 17.2% samples remained discrepant and in the second set - 13.4%. "Discrepant" sera were further tested in RIBA 3.0 and INNO-LIA immunoblot confirmatory assays, but approximately 5-7% of them remained undetermined after all the tests. For the samples with signal-to-cutoff ratio higher than 3.0 high rate of result consistency by reference, ELISA routing and INNO-LIA immunoblot assay was observed. On the other hand the results of tests 27 "problematic" sera in RIBA 3.0 and INNO-LIA were consistent only in 55.5% cases. Analysis of the antigen spectrum reactive with antibodies in "problematic" sera, demonstrated predominance of Core, NS3 and NS4 antigens for sera, positive in RIBA 3.0 and Core and NS3 antigens for sera, positive in INNO-LIA. To overcome the problem of undetermined sera, methods based on other principles, as well as alternative criteria of HCV infection diagnostics are discussed.

  17. Development of a highly sensitive and specific enzyme-linked immunosorbent assay (ELISA) for the detection of phenylethanolamine A in tissue and feed samples and confirmed by liquid chromatography tandem mass spectrometry (LC-MS/MS).

    PubMed

    Cao, Biyun; He, Guangzhao; Yang, Hong; Chang, Huafang; Li, Shuqun; Deng, Anping

    2013-10-15

    Phenylethanolamine A (PA) is a new emerged β-adrenergic agonist illegally used as feed additives for growth promotion. In this study, a highly sensitive and specific indirect competitive enzyme-linked immunosorbent assay (ELISA) for the detection of PA in tissue and feed samples was developed and confirmed by liquid chromatography tandem mass spectrometry (LC-MS/MS). By reduction of nitryl group to amino group, the PA derivative was synthesized and coupled to carrier proteins with diazobenzidine method. The antisera obtained from four immunized rabbits were characterized in terms of sensitivity and specificity. All antisera displayed high sensitivity with IC50 values lower than 0.48 ng mL(-1). The most sensitive ELISA was established with IC50 and limit of detection (LOD) values of 0.049 ng mL(-1) and 0.003 ng mL(-1), respectively. The cross-reactivity (CR) values of the antisera with three frequently used β-adrenergic agonists (clenbuterol, salbutamol and ractopamine) were lesser than 0.39%; there was no CR of the antisera with other six compounds including two structurally related substances (isoproterenol, phenylephrine). To investigate the accuracy and precision of the assay, swine kidney, liver, meat and feed samples were fortified with PA at different content and analyzed by ELISA. Acceptable recovery rates of 92.2-113.7% and intra-assay coefficients of variation of 3.8-10.9% (n=3) were achieved. Seven spiked samples were simultaneously analyzed by ELISA and LC-MS/MS. There was a high correlation coefficient of 0.9956 (n=7) between the two methods. The proposed ELISA proven to be a feasible quantitative/screening method for PA analysis in tissue and feed samples with the properties of high sensitivity and specificity, high sample throughput and low expensive. © 2013 Elsevier B.V. All rights reserved.

  18. Comparing Assay Performance of ELISA and Chemiluminescence Immunoassay in Detecting Antibodies to Hepatitis B Surface Antigen

    PubMed Central

    Sagar, Siddharth; Vishwanath, Shashidhar; Banerjee, Barnini; Eshwara, Vandana Kalwaje; Chawla, Kiran

    2016-01-01

    Introduction Antibodies to Hepatitis B surface Antigen (Anti-HBs) levels are measured as markers for immune response to vaccination and in decision making for post-exposure prophylaxis against Hepatitis-B. Several immunoassay formats are used to measure Anti-HBs, thus carrying the possibility of variation in measured levels between different assays. This study compares the performance of Chemiluminescence Immunoassay (CLIA) against Enzyme-linked Immunosorbent Assay (ELISA) in measuring Anti-HBs titer by looking into concordance between the two test reports. Aim To compare the agreement between ELISA and CLIA in measurement of Anti–HBs antibody titers. Materials and Methods This prospective comparative study conducted at Kasturba Medical College, Manipal measured consecutive serum samples (69) sent for anti-HBs levels during May-June 2016 using both CLIA (Abbott Architect) and ELISA (Bio-Rad). Anti-HBs values of ≤10mIU/ml was considered as non-protective and >10mIU/ml as protective. The agreement between the tests in classifying the antibody titers as non-protective or protective was computed using Kappa coefficient, and the difference in individual titer values between the tests compared using Bland-Altman plot on SPSS (v.15). Results Out of the 69 samples analysed, 18 samples (26.1%) were of health-care personnel and remaining of patients. Agreement between ELISA and CLIA in identifying the antibody titers as protective and non-protective were 96.5% and 90.9% respectively, resulting in an agreement of 0.84. The coefficient-of-variation of ELISA and CLIA were 74.5% and 113.1%, respectively. Three value based discordant results were noted; two samples deemed protective by ELISA were reported as non-protective by CLIA. One non-protective titer by ELISA was reported as protective by CLIA. Conclusion Analytical agreement is good between the two immunoassays. However there are some discrepancies in quantitative measurement. This may have been due the variation in the standard calibrators used in each assay. Though CLIA showed more variation in the values, it has the advantage of being automated test with low turn around time. Therefore, both the test methodologies can be reliably used in place of each other for detection of Anti- HBs titer. PMID:28050368

  19. Development and evaluation of an enzyme-linked immunosorbent assay (ELISA) method for the measurement of 2,4-dichlorophenoxyacetic acid in human urine.

    PubMed

    Chuang, Jane C; Emon, Jeanette M Van; Durnford, Joyce; Thomas, Kent

    2005-09-15

    An enzyme-linked immunosorbent assay (ELISA) method was developed to quantitatively measure 2,4-dichlorophenoxyacetic acid (2,4-D) in human urine. Samples were diluted (1:5) with phosphate-buffered saline containing 0.05% Tween and 0.02% sodium azide, with analysis by a 96-microwell plate immunoassay format. No clean up was required as dilution step minimized sample interferences. Fifty urine samples were received without identifiers from a subset of pesticide applicators and their spouses in an EPA pesticide exposure study (PES) and analyzed by the ELISA method and a conventional gas chromatography/mass spectrometry (GC/MS) procedure. For the GC/MS analysis, urine samples were extracted with acidic dichloromethane (DCM); methylated by diazomethane and fractionated by a Florisil solid phase extraction (SPE) column prior to GC/MS detection. The percent relative standard deviation (%R.S.D.) of the 96-microwell plate triplicate assays ranged from 1.2 to 22% for the urine samples. Day-to-day variation of the assay results was within +/-20%. Quantitative recoveries (>70%) of 2,4-D were obtained for the spiked urine samples by the ELISA method. Quantitative recoveries (>80%) of 2,4-D were also obtained for these samples by the GC/MS procedure. The overall method precision of these samples was within +/-20% for both the ELISA and GC/MS methods. The estimated quantification limit for 2,4-D in urine was 30ng/mL by ELISA and 0.2ng/mL by GC/MS. A higher quantification limit for the ELISA method is partly due to the requirement of a 1:5 dilution to remove the urine sample matrix effect. The GC/MS method can accommodate a 10:1 concentration factor (10mL of urine converted into 1mL organic solvent for analysis) but requires extraction, methylation and clean up on a solid phase column. The immunoassay and GC/MS data were highly correlated, with a correlation coefficient of 0.94 and a slope of 1.00. Favorable results between the two methods were achieved despite the vast differences in sample preparation. Results indicated that the ELISA method could be used as a high throughput, quantitative monitoring tool for human urine samples to identify individuals with exposure to 2,4-D above the typical background levels.

  20. Biomarkers of Selenium Action in Prostate Cancer

    DTIC Science & Technology

    2005-01-01

    secretory by conventional methods according to published literature. In addition, we have determined the similarities and differences in global gene...transition zone tissue of a 42-year-old man ac- arrays in the resulting data tables were ordered by their cording to previously described methods [4]. The pre...hundred fifteen genes identified by ELISA method . Replicating the conditions used for the SAM analysis showed significant differential expres- microarray

  1. Development and Validation of a High Throughput System for Discovery of Antigens for Autoantibody Detection

    PubMed Central

    Macdonald, Isabel K.; Allen, Jared; Murray, Andrea; Parsy-Kowalska, Celine B.; Healey, Graham F.; Chapman, Caroline J.; Sewell, Herbert F.; Robertson, John F. R.

    2012-01-01

    An assay employing a panel of tumor-associated antigens has been validated and is available commercially (EarlyCDT®-Lung) to aid the early detection of lung cancer by measurement of serum autoantibodies. The high throughput (HTP) strategy described herein was pursued to identify new antigens to add to the EarlyCDT-Lung panel and to assist in the development of new panels for other cancers. Two ligation-independent cloning vectors were designed and synthesized, producing fusion proteins suitable for the autoantibody ELISA. We developed an abridged HTP version of the validated autoantibody ELISA, determining that results reflected the performance of the EarlyCDT assay, by comparing results on both formats. Once validated this HTP ELISA was utilized to screen multiple fusion proteins prepared on small-scale, by a HTP expression screen. We determined whether the assay performance for these HTP protein batches was an accurate reflection of the performance of R&D or commercial batches. A HTP discovery platform for the identification and optimal production of tumor- associated antigens which detects autoantibodies has been developed and validated. The most favorable conditions for the exposure of immunogenic epitopes were assessed to produce discriminatory proteins for use in a commercial ELISA. This process is rapid and cost-effective compared to standard cloning and screening technologies and enables rapid advancement in the field of autoantibody assay discovery. This approach will significantly reduce timescale and costs for developing similar panels of autoantibody assays for the detection of other cancer types with the ultimate aim of improved overall survival due to early diagnosis and treatment. PMID:22815807

  2. Expression and Refolding of Truncated Recombinant Major Outer Membrane Protein Antigen (r56) of Orientia tsutsugamushi and Its Use in Enzyme-Linked Immunosorbent Assays

    PubMed Central

    Ching, W.-M.; Wang, H.; Eamsila, C.; Kelly, D. J.; Dasch, G. A.

    1998-01-01

    The variable 56-kDa major outer membrane protein of Orientia tsutsugamushi is the immunodominant antigen in human scrub typhus infections. The gene encoding this protein from Karp strain was cloned into the expression vector pET11a. The recombinant protein (r56) was expressed as a truncated nonfusion protein (amino acids 80 to 456 of the open reading frame) which formed an inclusion body when expressed in Escherichia coli BL21. Refolded r56 was purified and compared to purified whole-cell lysate of the Karp strain of O. tsutsugamushi by immunoglobulin G (IgG) enzyme-linked immunosorbent assay (ELISA) for reactivity with rabbit sera prepared against eight antigenic prototypes of O. tsutsugamushi as well as several other species of Rickettsiales and nonrickettsial antigens. Refolded r56 exhibited broad reactivity with the rabbit antisera against the Orientia prototypes, and the ELISA reactions with the r56 and Karp whole-cell lysate antigens correlated well (r = 0.81, n = 22, sensitivity compared to that of standard ELISA of 91%). Refolded r56 did not react with most antisera against other rickettsial species or control antigens (specificity = 92%, n = 13) using a positive cutoff value determined with eight uninfected rabbit sera. Refolded r56 was evaluated further by ELISA, using 128 sera obtained from patients with suspected scrub typhus from Korat, Thailand, and 74 serum specimens from healthy Thai soldiers. By using the indirect immunoperoxidase assay as the reference assay, the recombinant antigen exhibited a sensitivity and specificity of 93% or greater for detection of both IgG and IgM in the ELISA at 1:400 serum dilution. These results strongly suggest that purified r56 is a suitable candidate for replacing the density gradient-purified, rickettsia-derived, whole-cell antigen currently used in the commercial dipstick assay available in the United States. PMID:9665960

  3. Expression and refolding of truncated recombinant major outer membrane protein antigen (r56) of Orientia tsutsugamushi and its use in enzyme-linked immunosorbent assays.

    PubMed

    Ching, W M; Wang, H; Eamsila, C; Kelly, D J; Dasch, G A

    1998-07-01

    The variable 56-kDa major outer membrane protein of Orientia tsutsugamushi is the immunodominant antigen in human scrub typhus infections. The gene encoding this protein from Karp strain was cloned into the expression vector pET11a. The recombinant protein (r56) was expressed as a truncated nonfusion protein (amino acids 80 to 456 of the open reading frame) which formed an inclusion body when expressed in Escherichia coli BL21. Refolded r56 was purified and compared to purified whole-cell lysate of the Karp strain of O. tsutsugamushi by immunoglobulin G (IgG) enzyme-linked immunosorbent assay (ELISA) for reactivity with rabbit sera prepared against eight antigenic prototypes of O. tsutsugamushi as well as several other species of Rickettsiales and nonrickettsial antigens. Refolded r56 exhibited broad reactivity with the rabbit antisera against the Orientia prototypes, and the ELISA reactions with the r56 and Karp whole-cell lysate antigens correlated well (r = 0.81, n = 22, sensitivity compared to that of standard ELISA of 91%). Refolded r56 did not react with most antisera against other rickettsial species or control antigens (specificity = 92%, n = 13) using a positive cutoff value determined with eight uninfected rabbit sera. Refolded r56 was evaluated further by ELISA, using 128 sera obtained from patients with suspected scrub typhus from Korat, Thailand, and 74 serum specimens from healthy Thai soldiers. By using the indirect immunoperoxidase assay as the reference assay, the recombinant antigen exhibited a sensitivity and specificity of 93% or greater for detection of both IgG and IgM in the ELISA at 1:400 serum dilution. These results strongly suggest that purified r56 is a suitable candidate for replacing the density gradient-purified, rickettsia-derived, whole-cell antigen currently used in the commercial dipstick assay available in the United States.

  4. Development of an Enzyme-Linked Immunosorbent Assay Using a Recombinant LigA Fragment Comprising Repeat Domains 4 to 7.5 as an Antigen for Diagnosis of Equine Leptospirosis

    PubMed Central

    Yan, Weiwei; Saleem, Muhammad Hassan; McDonough, Patrick; McDonough, Sean P.; Divers, Thomas J.

    2013-01-01

    Leptospira immunoglobulin (Ig)-like (Lig) proteins are a novel family of surface-associated proteins in which the N-terminal 630 amino acids are conserved. In this study, we truncated the LigA conserved region into 7 fragments comprising the 1st to 3rd (LigACon1-3), 4th to 7.5th (LigACon4-7.5), 4th (LigACon4), 4.5th to 5.5th (LigACon4.5–5.5), 5.5th to 6.5th (LigACon5.5–6.5), 4th to 5th (LigACon4-5), and 6th to 7.5th (LigACon6-7.5) repeat domains. All 7 recombinant Lig proteins were screened using a slot-shaped dot blot assay for the diagnosis of equine leptospirosis. Our results showed that LigACon4-7.5 is the best candidate diagnostic antigen in a slot-shaped dot blot assay. LigACon4-7.5 was further evaluated as an indirect enzyme-linked immunosorbent assay (ELISA) antigen for the detection of Leptospira antibodies in equine sera. This assay was evaluated with equine sera (n = 60) that were microscopic agglutination test (MAT) negative and sera (n = 220) that were MAT positive to the 5 serovars that most commonly cause equine leptospirosis. The indirect ELISA results showed that at a single serum dilution of 1:250, the sensitivity and specificity of ELISA were 80.0% and 87.2%, respectively, compared to those of MAT. In conclusion, an indirect ELISA was developed utilizing a recombinant LigA fragment comprising the 4th to 7.5th repeat domain (LigACon4-7.5) as a diagnostic antigen for equine leptospirosis. This ELISA was found to be sensitive and specific, and it yielded results that concurred with those of the standard MAT. PMID:23720368

  5. An Application of Outer Membrane Protein P6-Specific Enzyme-Linked Immunosorbent Assay for Detection of Haemophilus influenzae in Middle Ear Fluids and Nasopharyngeal Secretions

    PubMed Central

    Hotomi, Muneki; Togawa, Akihisa; Kono, Masamitsu; Sugita, Gen; Sugita, Rinya; Fujimaki, Yutaka; Kamide, Yosuke; Uchizono, Akihiro; Kanesada, Keiko; Sawada, Shoichi; Okitsu, Naohiro; Masuda, Hisayo; Tanaka, Hideaki; Tanaka, Yumi; Yamanaka, Noboru

    2013-01-01

    An enzyme-linked immunosorbent assay specific to outer membrane protein P6 (P6-ELISA) was applied for detecting Haemophilus influenzae in middle ear fluids (MEFs) from acute otitis media (AOM) patients and in nasopharyngeal secretions (NPSs) from acute rhinosinusitis patients. P6-ELISA had a sensitivity of 83.3% for MEFs and 71.5% for NPSs and a specificity of 85.6% for MEFs and 92.5% for NPSs, respectively. Real-time PCR exhibited significant differences in the number of ompP1 gene copies among samples determined by P6-ELISA to be positive and negative for H. influenzae. However, because the P6-ELISA test has the reactivity in Haemophilus species include two commensals H. haemolyticus and H. parainfluenzae, it is thus a weak method in order to detect only NTHi correctly. Consequently, diagnosis using the P6-ELISA should be based on an overall evaluation, including the results of other related examinations and clinical symptoms to prevent misleading conclusions in clinical setting. PMID:24015192

  6. Development of an ELISA to detect circulating anti-asparaginase antibodies in dogs with lymphoid neoplasia treated with E. coli L-asparaginase*

    PubMed Central

    Kidd, Jason A.; Ross, Peter; Buntzman, Adam S.; Hess, Paul R.

    2012-01-01

    Resistance to E. coli L-asparaginase in canine lymphoma occurs frequently with repeated administration, a phenomenon often attributed, without substantiation, to the induction of neutralizing antibodies. To test the hypothesis that treated dogs develop antibodies against the drug, we created an ELISA to measure plasma anti-asparaginase IgG responses. Using samples from dogs that had received multiple doses, specific reactivity against L-asparaginase was demonstrated, while naïve patients’ samples were negative. The optimized ELISA appeared sensitive, with endpoint titers >1,600,000 in positive control dogs. Intra- and inter-assay coefficients of variation were 3.6 and 14.5%. The assay was supported by the observation that ELISA-positive plasma could immunoprecipitate asparaginase activity. When clinical patients were evaluated, 3/10 dogs developed titers after a single injection; with repeated administration, 4/7 dogs were positive. L-asparaginase antibodies showed reduced binding to the PEGylated drug formulation. The ELISA should prove useful in investigating the potential correlation of antibody responses with resistance. PMID:23253146

  7. An application of outer membrane protein p6-specific enzyme-linked immunosorbent assay for detection of haemophilus influenzae in middle ear fluids and nasopharyngeal secretions.

    PubMed

    Hotomi, Muneki; Togawa, Akihisa; Kono, Masamitsu; Sugita, Gen; Sugita, Rinya; Fujimaki, Yutaka; Kamide, Yosuke; Uchizono, Akihiro; Kanesada, Keiko; Sawada, Shoichi; Okitsu, Naohiro; Masuda, Hisayo; Tanaka, Hideaki; Tanaka, Yumi; Yamanaka, Noboru

    2013-01-01

    An enzyme-linked immunosorbent assay specific to outer membrane protein P6 (P6-ELISA) was applied for detecting Haemophilus influenzae in middle ear fluids (MEFs) from acute otitis media (AOM) patients and in nasopharyngeal secretions (NPSs) from acute rhinosinusitis patients. P6-ELISA had a sensitivity of 83.3% for MEFs and 71.5% for NPSs and a specificity of 85.6% for MEFs and 92.5% for NPSs, respectively. Real-time PCR exhibited significant differences in the number of ompP1 gene copies among samples determined by P6-ELISA to be positive and negative for H. influenzae. However, because the P6-ELISA test has the reactivity in Haemophilus species include two commensals H. haemolyticus and H. parainfluenzae, it is thus a weak method in order to detect only NTHi correctly. Consequently, diagnosis using the P6-ELISA should be based on an overall evaluation, including the results of other related examinations and clinical symptoms to prevent misleading conclusions in clinical setting.

  8. Antibody screening by enzyme-linked immunosorbent assay using pooled soluble HLA in renal transplant candidates.

    PubMed

    Zaer, F; Metz, S; Scornik, J C

    1997-01-15

    The enzyme-linked immunosorbent assay (ELISA) using HLA class I molecules purified from pooled platelets has the potential to detect HLA antibodies with increased efficiency without sacrificing sensitivity or specificity. This test, which was originally developed in our institution, has been independently validated by recent studies and is now commercially available. We now present evidence of its usefulness as a routine HLA antibody screening test for renal transplant patients. A total of 515 patients were tested monthly by ELISA (13.9 tests/patient) and by antiglobulin-enhanced panel reactivity (6.3 tests/patient). In patients found to be unsensitized, the incidence of false-positive results was less for ELISA than for the panel studies. In patients who were highly sensitized, both tests performed equally well, whereas discordant results were registered mainly in cases of mild sensitization. Because 66% of our patients were not sensitized, the ELISA was effective in reducing the number of more involved tests aimed at characterizing the antibodies. These results provide a foundation to use the pooled platelet HLA ELISA on a routine basis for HLA antibody screening.

  9. Fiber-optic microarray for simultaneous detection of multiple harmful algal bloom species.

    PubMed

    Ahn, Soohyoun; Kulis, David M; Erdner, Deana L; Anderson, Donald M; Walt, David R

    2006-09-01

    Harmful algal blooms (HABs) are a serious threat to coastal resources, causing a variety of impacts on public health, regional economies, and ecosystems. Plankton analysis is a valuable component of many HAB monitoring and research programs, but the diversity of plankton poses a problem in discriminating toxic from nontoxic species using conventional detection methods. Here we describe a sensitive and specific sandwich hybridization assay that combines fiber-optic microarrays with oligonucleotide probes to detect and enumerate the HAB species Alexandrium fundyense, Alexandrium ostenfeldii, and Pseudo-nitzschia australis. Microarrays were prepared by loading oligonucleotide probe-coupled microspheres (diameter, 3 mum) onto the distal ends of chemically etched imaging fiber bundles. Hybridization of target rRNA from HAB cells to immobilized probes on the microspheres was visualized using Cy3-labeled secondary probes in a sandwich-type assay format. We applied these microarrays to the detection and enumeration of HAB cells in both cultured and field samples. Our study demonstrated a detection limit of approximately 5 cells for all three target organisms within 45 min, without a separate amplification step, in both sample types. We also developed a multiplexed microarray to detect the three HAB species simultaneously, which successfully detected the target organisms, alone and in combination, without cross-reactivity. Our study suggests that fiber-optic microarrays can be used for rapid and sensitive detection and potential enumeration of HAB species in the environment.

  10. Validation of a KHV antibody enzyme-linked immunosorbent assay (ELISA).

    PubMed

    Bergmann, S M; Wang, Q; Zeng, W; Li, Y; Wang, Y; Matras, M; Reichert, M; Fichtner, D; Lenk, M; Morin, T; Olesen, N J; Skall, H F; Lee, P-Y; Zheng, S; Monaghan, S; Reiche, S; Fuchs, W; Kotler, M; Way, K; Bräuer, G; Böttcher, K; Kappe, A; Kielpinska, J

    2017-11-01

    Koi herpesvirus (KHV) causes KHV disease (KHVD). The virus is highly contagious in carp or koi and can induce a high mortality. Latency and, in some cases, a lack of signs presents a challenge for virus detection. Appropriate immunological detection methods for anti-KHV antibodies have not yet been fully validated for KHV. Therefore, it was developed and validated an enzyme-linked immunosorbent assay (ELISA) to detect KHV antibodies. The assay was optimized with respect to plates, buffers, antigens and assay conditions. It demonstrated high diagnostic and analytical sensitivity and specificity and was particularly useful at the pond or farm levels. Considering the scale of the carp and koi industry worldwide, this assay represents an important practical tool for the indirect detection of KHV, also in the absence of clinical signs. © 2017 John Wiley & Sons Ltd.

  11. Detection of Shiga toxin-producing Escherichia coli by sandwich enzyme-linked immunosorbent assay using chicken egg yolk IgY antibodies

    PubMed Central

    Parma, Y. R.; Chacana, P. A.; Lucchesi, P. M. A.; Rogé, A.; Granobles Velandia, C. V.; Krüger, A.; Parma, A. E.; Fernández-Miyakawa, M. E.

    2012-01-01

    Enterohemorrhagic Escherichia coli (EHEC), a subset of Shiga toxin producing E. coli (STEC) is associated with a spectrum of diseases that includes diarrhea, hemorrhagic colitis and a life-threatening hemolytic-uremic syndrome (HUS). Regardless of serotype, Shiga toxins (Stx1 and/or Stx2) are uniformly expressed by all EHEC, and so exploitable targets for laboratory diagnosis of these pathogens. In this study, a sandwich ELISA for determination of Shiga toxin (Stx) was developed using anti-Stx2B subunit antibodies and its performance was compared with that of the Vero cell assay and a commercial immunoassay kit. Chicken IgY was used as capture antibody and a HRP-conjugated rabbit IgG as the detection antibody. The anti-Stx2B IgY was harvested from eggs laid by hens immunized with a recombinant protein fragment. Several parameters were tested in order to optimize the sandwich ELISA assay, including concentration of antibodies, type and concentration of blocking agent, and incubation temperatures. Supernatants from 42 STEC strains of different serotypes and stx variants, including stx2EDL933, stx2vha, stx2vhb, stx2g, stx1EDL933, and stx1d were tested. All Stx variants were detected by the sandwich ELISA, with a detection limit of 115 ng/ml Stx2. Twenty three strains negative for stx genes, including different bacteria species, showed no activity in Vero cell assay and produced negative results in ELISA, except for two strains. Our results show that anti-Stx2B IgY sandwich ELISA could be used in routine diagnosis as a rapid, specific and economic method for detection of Shiga toxin-producing E. coli. PMID:22919675

  12. rTES-30USM: cloning via assembly PCR, expression, and evaluation of usefulness in the detection of toxocariasis.

    PubMed

    Norhaida, A; Suharni, M; Liza Sharmini, A T; Tuda, J; Rahmah, N

    2008-03-01

    Currently, the laboratory diagnosis of toxocariasis, caused by Toxocara canis or T. cati, mainly relies on serological tests. Unfortunately, however, the specificities of most of the commercial tests that are available for the serodiagnosis of this disease are not very high and this may cause problems, especially in tropical countries where co-infections with other helminths are common. In an effort to develop a serological assay with improved specificity for the detection of Toxocara infection, an IgG(4)-ELISA based on a recombinant version (rTES-30USM) of the 30-kDa Toxocara excretory-secretory antigen (TES-30) has recently been developed. To produce the antigen, the TES-30 gene was cloned via assembly PCR, subcloned into a His-tagged prokaryotic expression vector, and purified by affinity chromatography using Ni(2+)-nitrilotriacetic-acid (Ni-NTA) resin. The performance of the ELISA based on the recombinant antigen was then compared with that of commercial kit, based on an IgG-ELISA, for the serodiagnosis of toxocariasis (Toxocara IgG-ELISA; Cypress Diagnostics, Langdorp, Belgium). Both assays were used to test 338 serum samples, including 26 samples from probable cases of toxocariasis. Assuming that all the probable cases were true cases, the assay based on rTES-30USM demonstrated a sensitivity of 92.3% (24/26) and a specificity of 89.6% (103/115) whereas the commercial kit exhibited a sensitivity of 100% (26/26) but a specificity of only 55.7% (64/115). The high sensitivity and specificity exhibited by the new IgG(4)-ELISA should make the assay a good choice for use in tropical countries and any other area where potentially cross-reactive helminthic infections are common.

  13. Development of Two Antibody Detection Enzyme-Linked Immunosorbent Assays for Serodiagnosis of Human Chronic Fascioliasis

    PubMed Central

    Cabán-Hernández, Kimberly; Gaudier, José F.; Ruiz-Jiménez, Caleb

    2014-01-01

    Coprological examination based on egg detection in stool samples is currently used as the gold standard for the diagnosis of human fascioliasis. However, this method is not effective during the acute phase of the disease and has poor sensitivity during the chronic phase. Serodiagnosis has become an excellent alternative to coprological examination in efforts to combat the effects of fascioliasis on human and animal health. Two novel recombinant Fasciola hepatica proteins, i.e., a ferritin (FhFtn-1) and a tegument-associated protein (FhTP16.5), were used as antigens to develop in-house enzyme-linked immunosorbent assay (ELISA) methods. The assays were optimized and validated using 152 serum samples from humans with a known infection status, including healthy subjects, patients with chronic fascioliasis, and patients with other parasitic diseases. The FhFtn-1 ELISA was shown to be 96.6% sensitive and 95.7% specific; the respective parameters for the FhTP16.5 ELISA were 91.4% and 92.4%. The performances of the FhFtn-1 and FhTP16.5 ELISAs were compared with that of an available commercial test (the DRG test) using a subset of serum samples. Our in-house tests were slightly more sensitive than the DRG test in detecting antibodies against F. hepatica, but the differences were not statistically significant. In conclusion, the present study provides evidence for the potential of the FhFtn-1 and FhTP16.5 ELISAs as diagnostic tools for human fascioliasis, as might be implemented in conjunction with standard assays for large-scale screenings in areas where the disease is endemic and for the detection of occasional cases in clinical laboratories. PMID:24353000

  14. Evaluation of a novel Dot-ELISA assay utilizing a recombinant protein for the effective diagnosis of Taenia pisiformis larval infections.

    PubMed

    Chen, Lin; Yang, Deying; Gu, Xiaobin; Peng, Xuerong; Yang, Guangyou

    2014-08-29

    Cysticercosis, caused by the larvae of Taenia pisiformis, is a common disease in domestic breeds of the rabbit Oryctolagus cuniculus that results in economic losses. At present, there is no convenient and effective method for the rapid detection of T. pisiformis larvae. Here, we developed and tested the efficacy of a Dot-ELISA assay for the diagnosis of T. pisiformis larval infections in rabbits, based on the expression of the recombinant fusion protein (rTp1) from the Tp1 gene. Rapid amplification of cDNA ends (RACE) was used to amplify the 3' ends of the Tp1 gene, based on the unigene similar to Ts1 gene (EU009656.1) which comes from transcriptome sequencing of T. pisiformis. The Tp1 gene was successfully amplified, cloned and expressed in BL21 (DE3). Western blot analysis revealed that the recombinant Tp1 protein is specifically recognized by rabbit T. pisiformis cysticercosis antisera. This purified recombinant fusion protein, rTp1, was probed by Dot-ELISA with sera from rabbits infected with T. pisiformis larvae and with other parasitic infections. Results showed that this Dot-ELISA assay had both high sensitivity (92.9-97.6%) and specificity (95.2-98.4%) to detect T. pisiformis larval infections. We also found very low levels of cross-reaction with other parasitic infections. This study has revealed that our novel Dot-ELISA assay utilizing the recombinant fusion protein, rTp1, has a strong potential for the effective diagnosis of T. pisiformis infections in rabbits. Copyright © 2014 Elsevier B.V. All rights reserved.

  15. Development of two antibody detection enzyme-linked immunosorbent assays for serodiagnosis of human chronic fascioliasis.

    PubMed

    Cabán-Hernández, Kimberly; Gaudier, José F; Ruiz-Jiménez, Caleb; Espino, Ana M

    2014-03-01

    Coprological examination based on egg detection in stool samples is currently used as the gold standard for the diagnosis of human fascioliasis. However, this method is not effective during the acute phase of the disease and has poor sensitivity during the chronic phase. Serodiagnosis has become an excellent alternative to coprological examination in efforts to combat the effects of fascioliasis on human and animal health. Two novel recombinant Fasciola hepatica proteins, i.e., a ferritin (FhFtn-1) and a tegument-associated protein (FhTP16.5), were used as antigens to develop in-house enzyme-linked immunosorbent assay (ELISA) methods. The assays were optimized and validated using 152 serum samples from humans with a known infection status, including healthy subjects, patients with chronic fascioliasis, and patients with other parasitic diseases. The FhFtn-1 ELISA was shown to be 96.6% sensitive and 95.7% specific; the respective parameters for the FhTP16.5 ELISA were 91.4% and 92.4%. The performances of the FhFtn-1 and FhTP16.5 ELISAs were compared with that of an available commercial test (the DRG test) using a subset of serum samples. Our in-house tests were slightly more sensitive than the DRG test in detecting antibodies against F. hepatica, but the differences were not statistically significant. In conclusion, the present study provides evidence for the potential of the FhFtn-1 and FhTP16.5 ELISAs as diagnostic tools for human fascioliasis, as might be implemented in conjunction with standard assays for large-scale screenings in areas where the disease is endemic and for the detection of occasional cases in clinical laboratories.

  16. Exploiting Inhibitory Siglecs to Combat Food Allergies

    DTIC Science & Technology

    2017-10-01

    such as ELISAs . Shiteng and Kevin Worrell participated in groups meetings, regularly presenting their research updates. Dr. Macauley worked closely...transferred the cells into naïve animals and then immunized with Ara h 2. She also contributed by running some ELISA experiments. Funding Support...procedures and peanut challenges. She also assisted with cellular studies, flow cytometry, and ELISA . Kelly performed the human CD33 basophil assays as

  17. Development and evaluation of antibody-capture immunoassays for detection of Lassa virus nucleoprotein-specific immunoglobulin M and G

    PubMed Central

    Gabriel, Martin; Adomeh, Donatus I.; Ehimuan, Jacqueline; Oyakhilome, Jennifer; Omomoh, Emmanuel O.; Ighodalo, Yemisi; Olokor, Thomas; Bonney, Kofi; Pahlmann, Meike; Emmerich, Petra; Lelke, Michaela; Brunotte, Linda; Ölschläger, Stephan; Thomé-Bolduan, Corinna; Becker-Ziaja, Beate; Busch, Carola; Odia, Ikponmwosa; Ogbaini-Emovon, Ephraim; Okokhere, Peter O.; Okogbenin, Sylvanus A.; Akpede, George O.; Schmitz, Herbert; Asogun, Danny A.

    2018-01-01

    Background The classical method for detection of Lassa virus-specific antibodies is the immunofluorescence assay (IFA) using virus-infected cells as antigen. However, IFA requires laboratories of biosafety level 4 for assay production and an experienced investigator to interpret the fluorescence signals. Therefore, we aimed to establish and evaluate enzyme-linked immunosorbent assays (ELISA) using recombinant Lassa virus nucleoprotein (NP) as antigen. Methodology/Principal findings The IgM ELISA is based on capturing IgM antibodies using anti-IgM, and the IgG ELISA is based on capturing IgG antibody–antigen complexes using rheumatoid factor or Fc gamma receptor CD32a. Analytical and clinical evaluation was performed with 880 sera from Lassa fever endemic (Nigeria) and non-endemic (Ghana and Germany) areas. Using the IFA as reference method, we observed 91.5–94.3% analytical accuracy of the ELISAs in detecting Lassa virus-specific antibodies. Evaluation of the ELISAs for diagnosis of Lassa fever on admission to hospital in an endemic area revealed a clinical sensitivity for the stand-alone IgM ELISA of 31% (95% CI 25–37) and for combined IgM/IgG detection of 26% (95% CI 21–32) compared to RT-PCR. The specificity of IgM and IgG ELISA was estimated at 96% (95% CI 93–98) and 100% (95% CI 99–100), respectively, in non-Lassa fever patients from non-endemic areas. In patients who seroconverted during follow-up, Lassa virus-specific IgM and IgG developed simultaneously rather than sequentially. Consistent with this finding, isolated IgM reactivity, i.e. IgM in the absence of IgG, had no diagnostic value. Conclusions/Significance The ELISAs are not equivalent to RT-PCR for early diagnosis of Lassa fever; however, they are of value in diagnosing patients at later stage. The IgG ELISA may be useful for epidemiological studies and clinical trials due its high specificity, and the higher throughput rate and easier operation compared to IFA. PMID:29596412

  18. A NASBA on microgel-tethered molecular-beacon microarray for real-time microbial molecular diagnostics.

    PubMed

    Ma, Y; Dai, X; Hong, T; Munk, G B; Libera, M

    2016-12-19

    Despite their many advantages and successes, molecular beacon (MB) hybridization probes have not been extensively used in microarray formats because of the complicating probe-substrate interactions that increase the background intensity. We have previously shown that tethering to surface-patterned microgels is an effective means for localizing MB probes to specific surface locations in a microarray format while simultaneously maintaining them in as water-like an environment as possible and minimizing probe-surface interactions. Here we extend this approach to include both real-time detection together with integrated NASBA amplification. We fabricate small (∼250 μm × 250 μm) simplex, duplex, and five-plex assays with microarray spots of controllable size (∼20 μm diameter), position, and shape to detect bacteria and fungi in a bloodstream-infection model. The targets, primers, and microgel-tethered probes can be combined in a single isothermal reaction chamber with no post-amplification labelling. We extract total RNA from clinical blood samples and differentiate between Gram-positive and Gram-negative bloodstream infection in a duplex assay to detect RNA- amplicons. The sensitivity based on our current protocols in a simplex assay to detect specific ribosomal RNA sequences within total RNA extracted from S. aureus and E. coli cultures corresponds to tens of bacteria per ml. We furthermore show that the platform can detect RNA- amplicons from synthetic target DNA with 1 fM sensitivity in sample volumes that contain about 12 000 DNA molecules. These experiments demonstrate an alternative approach that can enable rapid and real-time microarray-based molecular diagnostics.

  19. Comparison of DOT-ELISA and Standard-ELISA for Detection of the Vibrio cholerae Toxin in Culture Supernatants of Bacteria Isolated from Human and Environmental Samples.

    PubMed

    Meza-Lucas, Antonio; Pérez-Villagómez, María-Fernanda; Martínez-López, José-Patricio; García-Rodea, Ricardo; Martínez-Castelán, María-Guadalupe; Escobar-Gutiérrez, Alejandro; de-la-Rosa-Arana, Jorge-Luis; Villanueva-Zamudio, Altagracia

    2016-09-01

    A comparison of DOT-ELISA and Standard-ELISA was made for detection of Vibrio cholerae toxin in culture supernatants of bacteria isolated from human and environmental samples. A total of 293 supernatants were tested in a double blind assay. A correlation of 100 % was obtained between both techniques. The cholera toxin was found in 20 Inaba and 3 Ogawa strains. Positive samples were from seafood (17 samples), potable water (1 sample) and sewage (5 samples). The DOT-ELISA was useful as the standard-ELISA to confirm the presence of cholera toxin in the environmental samples.

  20. DNA methylation profiling using HpaII tiny fragment enrichment by ligation-mediated PCR (HELP)

    PubMed Central

    Suzuki, Masako; Greally, John M.

    2010-01-01

    The HELP assay is a technique that allows genome-wide analysis of cytosine methylation. Here we describe the assay, its relative strengths and weaknesses, and the transition of the assay from a microarray to massively-parallel sequencing-based foundation. PMID:20434563

  1. Validation of an enzyme-linked immunosorbent assay that detects Histoplasma capsulatum antigenuria in Colombian patients with AIDS for diagnosis and follow-up during therapy.

    PubMed

    Caceres, Diego H; Scheel, Christina M; Tobón, Angela M; Ahlquist Cleveland, Angela; Restrepo, Angela; Brandt, Mary E; Chiller, Tom; Gómez, Beatriz L

    2014-09-01

    We validated an antigen capture enzyme-linked immunosorbent assay (ELISA) in Colombian persons with AIDS and proven histoplasmosis and evaluated the correlation between antigenuria and clinical improvement during follow-up. The sensitivity of the Histoplasma capsulatum ELISA was 86%, and the overall specificity was 94%. The antigen test successfully monitored the response to therapy. Copyright © 2014, American Society for Microbiology. All Rights Reserved.

  2. A semi-automated multiplex high-throughput assay for measuring IgG antibodies against Plasmodium falciparum erythrocyte membrane protein 1 (PfEMP1) domains in small volumes of plasma.

    PubMed

    Cham, Gerald K K; Kurtis, Jonathan; Lusingu, John; Theander, Thor G; Jensen, Anja T R; Turner, Louise

    2008-06-12

    The level of antibodies against PfEMP1 is routinely quantified by the conventional microtitre enzyme-linked immunosorbent assay (ELISA). However, ELISA only measures one analyte at a time and requires a relatively large plasma volume if the complete antibody profile of the sample is to be obtained. Furthermore, assay-to-assay variation and the problem of storage of antigen can influence ELISA results. The bead-based assay described here uses the BioPlex100 (BioRad, Hercules, CA, USA) system which can quantify multiple antibodies simultaneously in a small plasma volume. A total of twenty nine PfEMP1 domains were PCR amplified from 3D7 genomic DNA, expressed in the Baculovirus system and purified by metal-affinity chromatography. The antibody reactivity level to the recombinant PfEMP1 proteins in human hyper-immune plasma was measured by ELISA. In parallel, these recombinant PfEMP1 proteins were covalently coupled onto beads each having its own unique detection signal and the human hyper-immune plasma reactivity was detected for each individual protein using a BioPlex100 system. Protein-coupled beads were analysed at two time points seven months apart, before and after lyophilization and the results compared to determine the effect of storage and lyophilization respectively on the beads. Multiplexed protein-coupled beads from twenty eight unique bead populations were evaluated on the BioPlex100 system against pooled human hyper-immune plasma before and after lyophilization. The bead-based assay was sensitive, accurate and reproducible. Four recombinant PfEMP1 proteins C17, D5, D9 and D12, selected on the basis that they showed a spread of median fluorescent intensity (MFI) values from low to high when analysed by the bead-based assay were analysed by ELISA and the results from both analyses were highly correlated. The Spearman's rank correlation coefficients (Rho) were > or = 0.86, (P < 0.0001) for all comparisons. Bead-based assays gave similar results regardless of whether they were performed on individual beads or on multiplexed beads; lyophilization had no impact on the assay performance. Spearman's rank correlation coefficients (Rho) were > or = 0.97, (P < 0.0001) for all comparisons. Importantly, the reactivity of protein-coupled non-lyophilized beads decreased with long term storage at 4 degrees C in the dark. Using this lyophilized multiplex assay, antibody reactivity levels to twenty eight different recombinant PfEMP1 proteins were simultaneously measured using a single microliter of plasma. Thus, the assay reported here provides a useful tool for rapid and efficient quantification of antibody reactivity against PfEMP1 variants in human plasma.

  3. Salivary Desmoglein Enzyme-Linked Immunosorbent Assay for Diagnosis of Pemphigus Vulgaris: A Noninvasive Alternative Test to Serum Assessment

    PubMed Central

    Khatami, Alireza; Seyedin, Zahra; Daneshpazhooh, Maryam

    2015-01-01

    Background. Serum desmoglein enzyme-linked immunosorbent assay (ELISA) is used for the diagnosis and monitoring of pemphigus diseases. Objectives. To compare the diagnostic accuracy of salivary antidesmoglein (Dsg) 1 and 3 ELISA in the diagnosis of pemphigus vulgaris (PV) patients with that of serum desmogleins ELISA. Methods. Eighty-six untreated PV patients and 180 age- and sex-matched PV-free controls were recruited in this case-control study. PV was diagnosed based on clinical, histopathological, and direct immunofluorescence findings. After processing, serum and salivary anti-Dsg 1 and 3 were measured by the ELISA method using Euroimmun kit (Lübeck, Germany). Results. Using the cut-off point of 20 relative units (RU)/mL, the serum anti-Dsg 1 and 3 ELISA were positive in 62 (72.1%) and 83 (96.5%) patients, respectively, and the salivary anti-Dsg 1 and 3 ELISA were positive in 31 (36.1%) and 63 (73.3%) patients, respectively. The specificity of salivary anti-Dsg 1 and anti-Dsg 3 were both 98.9%. Optimal cut-off values of 7.7 and 13.4 RU/mL were determined for the salivary anti-Dsg 1 and anti-Dsg 3 ELISA, respectively. Conclusion. Salivary anti-Dsg 1 and 3 ELISA with high specificities (98.9%) could be suggested as safe and noninvasive methods for the diagnosis of PV when obtaining a blood sample is difficult. PMID:25688364

  4. A Colorimetric Enzyme-Linked Immunosorbent Assay (ELISA) Detection Platform for a Point-of-Care Dengue Detection System on a Lab-on-Compact-Disc

    PubMed Central

    Thiha, Aung; Ibrahim, Fatimah

    2015-01-01

    The enzyme-linked Immunosorbent Assay (ELISA) is the gold standard clinical diagnostic tool for the detection and quantification of protein biomarkers. However, conventional ELISA tests have drawbacks in their requirement of time, expensive equipment and expertise for operation. Hence, for the purpose of rapid, high throughput screening and point-of-care diagnosis, researchers are miniaturizing sandwich ELISA procedures on Lab-on-a-Chip and Lab-on-Compact Disc (LOCD) platforms. This paper presents a novel integrated device to detect and interpret the ELISA test results on a LOCD platform. The system applies absorption spectrophotometry to measure the absorbance (optical density) of the sample using a monochromatic light source and optical sensor. The device performs automated analysis of the results and presents absorbance values and diagnostic test results via a graphical display or via Bluetooth to a smartphone platform which also acts as controller of the device. The efficacy of the device was evaluated by performing dengue antibody IgG ELISA on 64 hospitalized patients suspected of dengue. The results demonstrate high accuracy of the device, with 95% sensitivity and 100% specificity in detection when compared with gold standard commercial ELISA microplate readers. This sensor platform represents a significant step towards establishing ELISA as a rapid, inexpensive and automatic testing method for the purpose of point-of-care-testing (POCT) in resource-limited settings. PMID:25993517

  5. Enzyme-linked immunosorbent assay for ultratrace determination of antibiotics in aqueous samples.

    PubMed

    Kumar, Kuldip; Thompson, Anita; Singh, Ashok K; Chander, Yogesh; Gupta, Satish C

    2004-01-01

    Two commercially available enzyme-linked immunosorbent assay (ELISA) kits that are commonly used for tylosin or tetracycline residues in meat and milk were adapted for ultratrace analysis of these antibiotics in surface and ground waters. These two antibiotics are commonly fed to swine, turkeys, and cattle at subtherapeutic doses for growth promotion purposes. Both ELISA techniques were found to be highly sensitive and selective for the respective antibiotics with detection limits of 0.10 and 0.05 microg L(-1) for tylosin and tetracycline, respectively. The recovery of both tylosin and tetracycline from spiked samples of lake waters, runoff samples, soil saturation extracts, and nanopure water was close to 100%. Tetracycline ELISA was highly specific for tetracycline and chlortetracycline but not for other forms of tetracycline (oxytetracycline, demeclocycline, and doxycycline). Analysis of a few liquid swine manure samples by liquid chromatography-mass spectrometry (LC-MS) showed lower concentrations for chlortetracycline as compared with concentrations obtained using ELISA. However, the concentrations of tylosin from ELISA were comparable with that of LC-MS. The lower concentrations of chlortetracycline obtained by LC-MS in manure samples indicate the presence of other similar or transformed compounds that were detected by ELISA but not determined by LC-MS. These results indicate that both ELISA kits can be useful tools for low-cost screening of tylosin, tetracycline, and chlortetracycline in environmental waters. Furthermore, both ELISA procedures are rapid, portable, and easily adaptable for testing of multiple samples simultaneously.

  6. Multiplexing T- and B-Cell FLUOROSPOT Assays: Experimental Validation of the Multi-Color ImmunoSpot® Software Based on Center of Mass Distance Algorithm.

    PubMed

    Karulin, Alexey Y; Megyesi, Zoltán; Caspell, Richard; Hanson, Jodi; Lehmann, Paul V

    2018-01-01

    Over the past decade, ELISPOT has become a highly implemented mainstream assay in immunological research, immune monitoring, and vaccine development. Unique single cell resolution along with high throughput potential sets ELISPOT apart from flow cytometry, ELISA, microarray- and bead-based multiplex assays. The necessity to unambiguously identify individual T and B cells that do, or do not co-express certain analytes, including polyfunctional cytokine producing T cells has stimulated the development of multi-color ELISPOT assays. The success of these assays has also been driven by limited sample/cell availability and resource constraints with reagents and labor. There are few commercially available test kits and instruments available at present for multi-color FLUOROSPOT. Beyond commercial descriptions of competing systems, little is known about their accuracy in experimental settings detecting individual cells that secrete multiple analytes vs. random overlays of spots. Here, we present a theoretical and experimental validation study for three and four color T- and B-cell FLUOROSPOT data analysis. The ImmunoSpot ® Fluoro-X™ analysis system we used includes an automatic image acquisition unit that generates individual color images free of spectral overlaps and multi-color spot counting software based on the maximal allowed distance between centers of spots of different colors or Center of Mass Distance (COMD). Using four color B-cell FLUOROSPOT for IgM, IgA, IgG1, IgG3; and three/four color T-cell FLUOROSPOT for IL-2, IFN-γ, TNF-α, and GzB, in serial dilution experiments, we demonstrate the validity and accuracy of Fluoro-X™ multi-color spot counting algorithms. Statistical predictions based on the Poisson spatial distribution, coupled with scrambled image counting, permit objective correction of true multi-color spot counts to exclude randomly overlaid spots.

  7. 77 FR 6471 - Bacillus thuringiensis Cry2Ae Protein in Cotton; Exemption from the Requirement of a Tolerance

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-08

    ... analytical method using enzyme- linked immunosorbent assay (ELISA) analyses for the qualitative detection of... study conducted by an independent third party laboratory to evaluate the ELISA test kit's performance as...

  8. Sandwich enzyme-linked immunosorbent assay (ELISA) for measuring the concentration of, and detection of antibodies to, Aujeszky's disease virus.

    PubMed

    Kardi, V; Szegletes, E; Perényi, T; Pergel, I; Smal, Z

    1990-01-01

    A double antibody sandwich enzyme-linked immunosorbent assay (ELISA) was developed for measuring Aujeszky's disease virus (ADV) antigen concentration and an inhibition technique based on the former was developed for detection of antibodies to ADV. The results were checked by determining the cytopathic and serum neutralization titres. The correlation was satisfactory in both cases, with correlation coefficients above 0.8. When measuring ADV antigen concentration, the lower limit of detection was 10(3) TCID 50/0.2 ml. The sensitivity of ELISA in detecting antibodies to ADV was found to be superior to that of the serum neutralization test and, thus, enabled the testing of rabbit and guinea-pig sera.

  9. LDRD final report on microencapsulated immunoreagents for development of one-step ELISA

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Henderson, C.C.; Singh, A.K.

    1997-08-01

    Microencapsulation of biological macromolecules was investigated as a method for incorporating the necessary immunoreagents into an improved enzyme-linked immunosorbant assay (ELISA) package that would self-develop. This self-contained ELISA package would eliminate the need for a trained technician to perform multiple additions of immunoreagent to the assay. Microencapsulation by insolution drying was selected from the many available microencapsulation methods, and two satisfactory procedures for microencapsulation of proteins were established. The stability and potential for rapid release of protein from these microencapsulates was then evaluated. The results suggest that the chosen method for protein entrapment produces microcapsules with a considerable amount ofmore » protein in the walls making these particular microcapsules unsuitable for their intended use.« less

  10. An alternative method to amplify RNA without loss of signal conservation for expression analysis with a proteinase DNA microarray in the ArrayTube format.

    PubMed

    Schüler, Susann; Wenz, Ingrid; Wiederanders, B; Slickers, P; Ehricht, R

    2006-06-12

    Recent developments in DNA microarray technology led to a variety of open and closed devices and systems including high and low density microarrays for high-throughput screening applications as well as microarrays of lower density for specific diagnostic purposes. Beside predefined microarrays for specific applications manufacturers offer the production of custom-designed microarrays adapted to customers' wishes. Array based assays demand complex procedures including several steps for sample preparation (RNA extraction, amplification and sample labelling), hybridization and detection, thus leading to a high variability between several approaches and resulting in the necessity of extensive standardization and normalization procedures. In the present work a custom designed human proteinase DNA microarray of lower density in ArrayTube format was established. This highly economic open platform only requires standard laboratory equipment and allows the study of the molecular regulation of cell behaviour by proteinases. We established a procedure for sample preparation and hybridization and verified the array based gene expression profile by quantitative real-time PCR (QRT-PCR). Moreover, we compared the results with the well established Affymetrix microarray. By application of standard labelling procedures with e.g. Klenow fragment exo-, single primer amplification (SPA) or In Vitro Transcription (IVT) we noticed a loss of signal conservation for some genes. To overcome this problem we developed a protocol in accordance with the SPA protocol, in which we included target specific primers designed individually for each spotted oligomer. Here we present a complete array based assay in which only the specific transcripts of interest are amplified in parallel and in a linear manner. The array represents a proof of principle which can be adapted to other species as well. As the designed protocol for amplifying mRNA starts from as little as 100 ng total RNA, it presents an alternative method for detecting even low expressed genes by microarray experiments in a highly reproducible and sensitive manner. Preservation of signal integrity is demonstrated out by QRT-PCR measurements. The little amounts of total RNA necessary for the analyses make this method applicable for investigations with limited material as in clinical samples from, for example, organ or tumour biopsies. Those are arguments in favour of the high potential of our assay compared to established procedures for amplification within the field of diagnostic expression profiling. Nevertheless, the screening character of microarray data must be mentioned, and independent methods should verify the results.

  11. Application of BALB/c mouse in the local lymph node assay:BrdU-ELISA for the prediction of the skin sensitizing potential of chemicals.

    PubMed

    Hou, Fenxia; Xing, Caihong; Li, Bin; Cheng, Juan; Chen, Wei; Zhang, Man

    2015-01-01

    Allergic contact dermatitis (ACD) is a skin disease characterized by eczema and itching. A considerable proportion of chemicals induce ACD in humans. More than 10,000 substances should be tested for skin sensitization potential under the Registration, Evaluation, Authorization and Restriction of Chemical substances (REACH) regulation. The Local Lymph Node Assay (LLNA) has been designated as the first-choice in vivo assay for sensitization testing by REACH. The LLNA:BrdU-ELISA is a validated non-radioactive modification to the LLNA. For both the LLNA and the LLNA:BrdU-ELISA, CBA/JN mouse is the preferred mouse strain recommended in the regulatory guidelines. However, the availability of CBA/JN mouse in China is only limited to a few animal suppliers, which makes the mouse difficult to obtain. BALB/c mouse, which is widely commercially available, is considered for alternative use but it can only be used in the assay after it has been evaluated by formal validation study. Thus, a validation study was conducted in our laboratory to determine if BALB/c mouse could also be used in the LLNA:BrdU-ELISA. Forty-three test substances including 32 LLNA sensitizers and 11 LLNA non-sensitizers, their vehicles and each concentration used were the same as that used in the formal validation study for the LLNA:BrdU-ELISA using CBA/JN mouse. Female BALB/c mice of 8-10 weeks old were randomly allocated to groups (four mice per group). The test substance (25 μl) or the vehicle alone was applied to the dorsum of both ears daily for 3 consecutive days. A single intraperitoneal injection of 0.5 ml of BrdU (10mg/ml) solution was given on day 5. On day 6, a pair of auricular lymph nodes from each mouse was excised, weighed and stored at -20°C until BrdU-ELISA was conducted. This validation study for the LLNA:BrdU-ELISA using BALB/c mouse correctly identified 30 of 31 sensitizers and 8 of 11 non-sensitizers. The accuracy, sensitivity, specificity, false positive rate, false negative rate, positive predictivity values and negative predictivity values in this study, which could indicate the performance of the LLNA:BrdU-ELISA using BALB/c mouse, were not different statistically from that of the validation study for the LLNA:BrdU-ELISA using CBA/JN mouse. This validation study indicates that BALB/c mouse could be used alternatively in the LLNA:BrdU-ELISA for the prediction of the skin sensitizing potential of chemicals. Copyright © 2015 Elsevier Inc. All rights reserved.

  12. Comparison of Protein Immunoprecipitation-Multiple Reaction Monitoring with ELISA for Assay of Biomarker Candidates in Plasma

    PubMed Central

    2013-01-01

    Quantitative analysis of protein biomarkers in plasma is typically done by ELISA, but this method is limited by the availability of high-quality antibodies. An alternative approach is protein immunoprecipitation combined with multiple reaction monitoring mass spectrometry (IP-MRM). We compared IP-MRM to ELISA for the analysis of six colon cancer biomarker candidates (metalloproteinase inhibitor 1 (TIMP1), cartilage oligomeric matrix protein (COMP), thrombospondin-2 (THBS2), endoglin (ENG), mesothelin (MSLN) and matrix metalloproteinase-9 (MMP9)) in plasma from colon cancer patients and noncancer controls. Proteins were analyzed by multiplex immunoprecipitation from plasma with the ELISA capture antibodies, further purified by SDS-PAGE, digested and analyzed by stable isotope dilution MRM. IP-MRM provided linear responses (r = 0.978–0.995) between 10 and 640 ng/mL for the target proteins spiked into a “mock plasma” matrix consisting of 60 mg/mL bovine serum albumin. Measurement variation (coefficient of variation at the limit of detection) for IP-MRM assays ranged from 2.3 to 19%, which was similar to variation for ELISAs of the same samples. IP-MRM and ELISA measurements for all target proteins except ENG were highly correlated (r = 0.67–0.97). IP-MRM with high-quality capture antibodies thus provides an effective alternative method to ELISA for protein quantitation in biological fluids. PMID:24224610

  13. Comparison of diagnostic value of indirect immunofluorescence assay and desmoglein ELISA in the diagnosis of pemphigus.

    PubMed

    Marinović, Branka; Fabris, Zrinka; Lipozencić, Jasna; Stulhofer Buzina, Daska; Lakos Jukić, Ines

    2010-01-01

    Pemphigus vulgaris (PV) and pemphigus foliaceus (PF) are autoimmune blistering diseases characterized by intraepidermal separation as the result of autoantibodies directed to desmoglein 1 and desmoglein 3, adhesion molecules that have a pathogenic role in blister formation. Both PV and PF are diagnosed according to clinical picture, histopathologic, immunopathologic and molecular biologic features. In the present study, the value of indirect immunofluorescence (IIF) and enzyme linked immunosorbent assay (ELISA) for desmoglein 1 (Dsg 1) and desmoglein 3 (Dsg 3) at baseline visit was compared. The study was performed as a retrospective study that included 22 patients, 19 of them with PV and three with PF. Patient sera were tested with IIF and Dsg 1 and Dsg 3 ELISA. In the group of 19 PV patients, 12 patients had positive IIF, Dsg 3 and Dsg 1 ELISA; two had positive IIF and positive anti Dsg 3 but negative anti Dsg 1; three had negative IIF but positive both Dsg 1 and Dsg 3 antibodies; and two had negative IIF and Dsg 1 but positive Dsg 3 antibodies. In the group of PF patients, all three patients had positive IIF, positive Dsg 1 ELISA and negative Dsg 3 ELISA. Results of our study supported previous reports confirming Dsg 1 and Dsg 3 ELISA to be a sensitive and specific tool for the diagnosis of PV and PF.

  14. HPV16 seropositivity and subsequent HPV16 infection risk in a naturally infected population: comparison of serological assays.

    PubMed

    Lin, Shih-Wen; Ghosh, Arpita; Porras, Carolina; Markt, Sarah C; Rodriguez, Ana Cecilia; Schiffman, Mark; Wacholder, Sholom; Kemp, Troy J; Pinto, Ligia A; Gonzalez, Paula; Wentzensen, Nicolas; Esser, Mark T; Matys, Katie; Meuree, Ariane; Quint, Wim; van Doorn, Leen-Jan; Herrero, Rolando; Hildesheim, Allan; Safaeian, Mahboobeh

    2013-01-01

    Several serological assays have been developed to detect antibodies elicited against infections with oncogenic human papillomavirus (HPV) type 16. The association between antibody levels measured by various assays and subsequent HPV infection risk may differ. We compared HPV16-specific antibody levels previously measured by a virus-like particle (VLP)-based direct enzyme-linked immunoassay (ELISA) with levels measured by additional assays and evaluated the protection against HPV16 infection conferred at different levels of the assays. Replicate enrollment serum aliquots from 388 unvaccinated women in the control arm of the Costa Rica HPV vaccine trial were measured for HPV16 seropositivity using three serological assays: a VLP-based direct ELISA; a VLP-based competitive Luminex immunoassay (cLIA); and a secreted alkaline phosphatase protein neutralization assay (SEAP-NA). We assessed the association of assay seropositivity and risk of subsequent HPV16 infection over four years of follow-up by calculating sampling-adjusted odds ratios (OR) and HPV16 seropositivity based on standard cutoff from the cLIA was significantly associated with protection from subsequent HPV16 infection (OR = 0.48, CI = 0.27-0.86, compared with seronegatives). Compared with seronegatives, the highest seropositive tertile antibody levels from the direct ELISA (OR = 0.53, CI = 0.28-0.90) as well as the SEAP-NA (OR = 0.20, CI = 0.06, 0.64) were also significantly associated with protection from HPV16 infection. Enrollment HPV16 seropositivity by any of the three serological assays evaluated was associated with protection from subsequent infection, although cutoffs for immune protection were different. We defined the assays and seropositivity levels after natural infection that better measure and translate to protective immunity.

  15. Quantification of the activity of biomolecules in microarrays obtained by direct laser transfer.

    PubMed

    Dinca, V; Ranella, A; Farsari, M; Kafetzopoulos, D; Dinescu, M; Popescu, A; Fotakis, C

    2008-10-01

    The direct-writing technique laser-induced forward transfer has been employed for the micro-array printing of liquid solutions of the enzyme horseradish peroxidase and the protein Titin on nitrocellulose solid surfaces. The effect of two UV laser pulse lengths, femtosecond and nanosecond has been studied in relation with maintaining the activity of the transferred biomolecules. The quantification of the active biomolecules after transfer has been carried out using Bradford assay, quantitative colorimetric enzymatic assay and fluorescence techniques. Spectrophotometric measurements of the HRP and the Titin activity as well as chromatogenic and fluorescence assay studies have revealed a connection between the properties of the deposited, biologically active biomolecules, the experimental conditions and the target composition. The bioassays have shown that up to 78% of the biomolecules remained active after femtosecond laser transfer, while this value reduced to 54% after nanosecond laser transfer. The addition of glycerol in a percentage up to 70% in the solution to be transferred has contributed to the stabilization of the micro-array patterns and the increase of their resolution.

  16. A microplate assay to measure classical and alternative complement activity.

    PubMed

    Puissant-Lubrano, Bénédicte; Fortenfant, Françoise; Winterton, Peter; Blancher, Antoine

    2017-05-01

    We developed and validated a kinetic microplate hemolytic assay (HA) to quantify classical and alternative complement activity in a single dilution of human plasma or serum. The assay is based on monitoring hemolysis of sensitized sheep (or uncoated rabbit) red blood cells by means of a 96-well microplate reader. The activity of the calibrator was evaluated by reference to 200 healthy adults. The conversion of 50% hemolysis time into a percentage of activity was obtained using a calibration curve plotted daily. The linearity of the assay as well as interference (by hemolysis, bilrubinemia and lipemia) was assessed for classical pathway (CP). The within-day and the between-day precision was satisfactory regarding the performance of commercially available liposome immunoassay (LIA) and ELISA. Patients with hereditary or acquired complement deficiencies were detected (activity was measured <30%). We also provided a reference range obtained from 200 blood donors. The agreement of CP evaluated on samples from 48 patients was 94% with LIA and 87.5% with ELISA. The sensitivity of our assay was better than that of LIA, and the cost was lower than either LIA or ELISA. In addition, this assay was less time consuming than previously reported HAs. This assay allows the simultaneous measurement of 36 samples in duplicate per run of a 96-well plate. The use of a daily calibration curve allows standardization of the method and leads to good reproducibility. The same technique was also adapted for the quantification of alternative pathway (AP) activity.

  17. Validation of 2 commercially available enzyme-linked immunosorbent assays for adiponectin determination in canine serum samples.

    PubMed

    Tvarijonaviciute, Asta; Martínez-Subiela, Silvia; Ceron, José J

    2010-10-01

    The aim of this study was to validate 2 commercially available enzyme-linked immunosorbent assays (ELISAs) for adiponectin in dogs, 1 canine-specific and 1 originally designed for measurements in humans. Intra-assay and interassay precision was evaluated by multiple measurements in canine serum samples, and assay accuracy was indirectly determined by linearity under dilution. Interference caused by hemolysis and lipemia was also studied. Both assays were subsequently used for measuring adiponectin concentrations in clinically healthy dogs and those with different grades of obesity. The intra-assay and inter-assay precision was less than 7.5% and 13.5% in serum samples with low and high adiponectin concentrations, respectively. Lipemia and hemolysis did not affect the results of any of the assays. Both assays were able to differentiate lean dogs from those that were overweight or obese on the basis of the measured adiponectin concentrations. From these results it can be concluded that canine adiponectin concentrations can be measured reliably by means of the 2 ELISAs evaluated in this study.

  18. Validation of 2 commercially available enzyme-linked immunosorbent assays for adiponectin determination in canine serum samples

    PubMed Central

    Tvarijonaviciute, Asta; Martínez-Subiela, Silvia; Ceron, José J.

    2010-01-01

    The aim of this study was to validate 2 commercially available enzyme-linked immunosorbent assays (ELISAs) for adiponectin in dogs, 1 canine-specific and 1 originally designed for measurements in humans. Intra-assay and interassay precision was evaluated by multiple measurements in canine serum samples, and assay accuracy was indirectly determined by linearity under dilution. Interference caused by hemolysis and lipemia was also studied. Both assays were subsequently used for measuring adiponectin concentrations in clinically healthy dogs and those with different grades of obesity. The intra-assay and inter-assay precision was less than 7.5% and 13.5% in serum samples with low and high adiponectin concentrations, respectively. Lipemia and hemolysis did not affect the results of any of the assays. Both assays were able to differentiate lean dogs from those that were overweight or obese on the basis of the measured adiponectin concentrations. From these results it can be concluded that canine adiponectin concentrations can be measured reliably by means of the 2 ELISAs evaluated in this study. PMID:21197228

  19. Variability in assays used for detection of lentiviral infection in bobcats (Lynx rufus), pumas (Puma concolor), and ocelots (Leopardus pardalis)

    USGS Publications Warehouse

    Franklin, S.P.; Troyer, J.L.; TerWee, J.A.; Lyren, L.M.; Kays, R.W.; Riley, S.P.D.; Boyce, W.M.; Crooks, K.R.; VandeWoude, S.

    2007-01-01

    Although lentiviruses similar to feline immunodeficiency virus (FIV) are known to infect numerous felid species, the relative utility of assays used for detecting lentiviral infection has not been compared for many of these hosts. We tested bobcats (Lynx rufus), pumas (Felis concolor), and ocelots (Leopardus pardalis) for exposure to lentivirus using five different assays: puma lentivirus (PLV), African lion lentivirus (LLV), and domestic cat FIV-based immunoblots, a commercially available enzyme-linked immunosorbent assay (ELISA) kit, and nested polymerase chain reaction (PCR). Puma lentivirus immunoblots identified more seropositive individuals than the other antibody-detection assays. The commercial ELISA provided a fair ability to recognize seropositive samples when compared with PLV immunoblot for screening bobcats and ocelots, but not pumas. Polymerase chain reaction identified fewer positive samples than PLV immunoblot for all three species. Immunoblot results were equivalent whether the sample tested was serum, plasma, or whole blood. The results from this study and previous investigations suggest that the PLV immunoblot has the greatest ability to detect reactive samples when screening wild felids of North America and is unlikely to produce false positive results. However, the commercial ELISA kit may provide ap adequate alternative for screening of some species and is more easily adapted to field conditions. ?? Wildlife Disease Association 2007.

  20. Simple Identification of Human Taenia Species by Multiplex Loop-Mediated Isothermal Amplification in Combination with Dot Enzyme-Linked Immunosorbent Assay.

    PubMed

    Nkouawa, Agathe; Sako, Yasuhito; Okamoto, Munehiro; Ito, Akira

    2016-06-01

    For differential detection of Taenia solium, Taenia saginata, and Taenia asiatica, loop-mediated isothermal amplification (LAMP) assay targeting the cytochrome c oxidase subunit 1 gene has been recently developed and shown to be sensitive, specific, and effective. However, to achieve differential identification, one specimen requires three reaction mixtures containing a primer set of each Taenia species separately, which is complex and time consuming and increases the risk of cross-contamination. In this study, we developed a simple differential identification of human Taenia species using multiplex LAMP (mLAMP) in combination with dot enzyme-linked immunosorbent assay (dot-ELISA). Forward inner primers of T. solium, T. saginata, and T. asiatica labeled with fluorescein isothiocyanate (FITC), digoxigenin (DIG), and tetramethylrhodamine (TAMRA), respectively, and biotin-labeled backward inner primers were used in mLAMP. The mLAMP assay succeeded in specific amplification of each respective target gene in a single tube. Furthermore, the mLAMP product from each species was easily distinguished by dot-ELISA with an antibody specific for FITC, DIG, or TAMRA. The mLAMP assay in combination with dot-ELISA will make identification of human Taenia species simpler, easier, and more practical. © The American Society of Tropical Medicine and Hygiene.

Top