Sample records for elution process solutions

  1. Analysis of the effects of stirring condition of separation of thorium in the elution process of monazite partial solution by solvent impregnated resin method

    NASA Astrophysics Data System (ADS)

    Prassanti, R.; Putra, D. S.; Kusuma, B. P.; Nawawi, F. W.

    2018-01-01

    Monazite is a natural mineral which contains abundant valuable element such as Radioactive Element and Rare Earth Element(REE). In this experiment, it is proven that solution of residual Thorium Sulfate from Monazite mineral process, can be seperated selectively by using extracting method of Solvent Impregnated Resin(SIR), with the elutant solution HNO3. In the earlier process, Thorium solution is conditioned at PH 1 by using H2SO4. Then REE, Thorium and Uranium elements are seperated. This seperation is conducted by using adsorption method by Amberlite XAD-16 Resin, which has been impregnated by Tributhyl Phosphate extractant. It is continued with elution process, which is aimed to obtain Thorium solution of a higher level of concentration. This elution process is conducted by using HNO3, with the elution variables of the lenght of mixing and amount concentration elutant. Based on this experiment, SIR extracting method is able to dissolve Thorium solution until 63,2%grade and a higher level of %grade about 92,40%. It can be concluded that this SIR method can extracted Thorium elements selectively, improve extracting process recovery, and determine optimum stripping condition in the 45th minutes with elutant concentration of 1,0M HNO3.

  2. ION EXCHANGE ADSORPTION PROCESS FOR PLUTONIUM SEPARATION

    DOEpatents

    Boyd, G.E.; Russell, E.R.; Taylor, M.D.

    1961-07-11

    Ion exchange processes for the separation of plutonium from fission products are described. In accordance with these processes an aqueous solution containing plutonium and fission products is contacted with a cation exchange resin under conditions favoring adsorption of plutonium and fission products on the resin. A portion of the fission product is then eluted with a solution containing 0.05 to 1% by weight of a carboxylic acid. Plutonium is next eluted with a solution containing 2 to 8 per cent by weight of the same carboxylic acid, and the remaining fission products on the resin are eluted with an aqueous solution containing over 10 per cent by weight of sodium bisulfate.

  3. Analysis of solute-protein interactions and solute-solute competition by zonal elution affinity chromatography.

    PubMed

    Tao, Pingyang; Poddar, Saumen; Sun, Zuchen; Hage, David S; Chen, Jianzhong

    2018-02-02

    Many biological processes involve solute-protein interactions and solute-solute competition for protein binding. One method that has been developed to examine these interactions is zonal elution affinity chromatography. This review discusses the theory and principles of zonal elution affinity chromatography, along with its general applications. Examples of applications that are examined include the use of this method to estimate the relative extent of solute-protein binding, to examine solute-solute competition and displacement from proteins, and to measure the strength of these interactions. It is also shown how zonal elution affinity chromatography can be used in solvent and temperature studies and to characterize the binding sites for solutes on proteins. In addition, several alternative applications of zonal elution affinity chromatography are discussed, which include the analysis of binding by a solute with a soluble binding agent and studies of allosteric effects. Other recent applications that are considered are the combined use of immunoextraction and zonal elution for drug-protein binding studies, and binding studies that are based on immobilized receptors or small targets. Copyright © 2018 Elsevier Inc. All rights reserved.

  4. ELUTION OF URANIUM VALUES FROM ION EXCHANGE RESINS

    DOEpatents

    Kennedy, R.H.

    1959-11-24

    A process is described for eluting complex uranium ions absorbed on ion exchange resins. The resin is subjected to the action of an aqueous eluting solution contuining sulfuric acid and an alkali metal, ammonium, or magnesium chloride or nitrate, the elution being carried out until the desired amount of the uranium is removed from the resin.

  5. Multiple dual mode counter-current chromatography with variable duration of alternating phase elution steps.

    PubMed

    Kostanyan, Artak E; Erastov, Andrey A; Shishilov, Oleg N

    2014-06-20

    The multiple dual mode (MDM) counter-current chromatography separation processes consist of a succession of two isocratic counter-current steps and are characterized by the shuttle (forward and back) transport of the sample in chromatographic columns. In this paper, the improved MDM method based on variable duration of alternating phase elution steps has been developed and validated. The MDM separation processes with variable duration of phase elution steps are analyzed. Basing on the cell model, analytical solutions are developed for impulse and non-impulse sample loading at the beginning of the column. Using the analytical solutions, a calculation program is presented to facilitate the simulation of MDM with variable duration of phase elution steps, which can be used to select optimal process conditions for the separation of a given feed mixture. Two options of the MDM separation are analyzed: 1 - with one-step solute elution: the separation is conducted so, that the sample is transferred forward and back with upper and lower phases inside the column until the desired separation of the components is reached, and then each individual component elutes entirely within one step; 2 - with multi-step solute elution, when the fractions of individual components are collected in over several steps. It is demonstrated that proper selection of the duration of individual cycles (phase flow times) can greatly increase the separation efficiency of CCC columns. Experiments were carried out using model mixtures of compounds from the GUESSmix with solvent systems hexane/ethyl acetate/methanol/water. The experimental results are compared to the predictions of the theory. A good agreement between theory and experiment has been demonstrated. Copyright © 2014 Elsevier B.V. All rights reserved.

  6. ANIONIC EXCHANGE PROCESS FOR THE RECOVERY OF URANIUM AND VANADIUM FROM CARBONATE SOLUTIONS

    DOEpatents

    Bailes, R.H.; Ellis, D.A.; Long, R.S.

    1958-12-16

    Uranium and vanadium can be economically purified and recovered from non- salt roast carbonate leach liquors by adsorption on a strongly basic anionic exchange resin and subsequent selective elution by one of three alternative methods. Method 1 comprises selectively eluting uranium from the resin with an ammonium sulfate solution followed by eluting vanadium from the resin with either 5 M NaCl, saturated (NH/sub 4/)/sub 2/CO/sub 3/, saturated NaHCO/sub 3/, 1 M NaOH, or saturated S0/sub 2/ solutions. Method II comprises selectively eluting vanadium from the resin with either concentrated NaCl or S0/sub 2/ solutions subsequent to pretreatment of the column with either S0/sub 2/ gas, 1 N HCl, or 0.1 N H/sub 2/8O/sub 4/ followed by eluting uranium from the resin with solutions containing 0.9 M NH/sub 4/Cl or NaCl and 0.1 Cl. Method III comprises flowing the carbonate leac solutlon through a first column of a strongly basic anlonlc exchange resin untll vanadium breakthrough occurs, so that the effluent solution is enriched ln uranium content and the vanadium is chiefly retalned by the resln, absorbing the uranlum from the enriched effluent solution on a second column of a strongly basic anionic exchange resin, pretreating the first column with either 0.1 N HCl, 0.1 H/sub 2/SO/sub 4/, C0/sub 2/ gas, or ammonium sulfate, selectively eluting the vanadlum from the column with saturated S0/sub 2/ solution, pretreatlng the second column with either 0.1 N HCl or S0/sub 2/ gas, selectively eluting residual vanadium from the column with saturated S0/sub 2/ solution, and then eluting the uranium from the column with either 0.1 N HCl and 1 N NaCl orO.l N HCl and 1 N NH/sub 4/Cl.

  7. ADSORPTION PROCEDURE IN PREPARING U$sup 23$$sup 3$

    DOEpatents

    Stoughton, R.W.

    1958-10-14

    A process is presented for the separation of protoactinium and thorium from an aqueous nitric acid solution containing these metals. It comprises contacting the solution with a cation exchange phenol-formaldehyde resin containing sulfonic acid groups, and eluting the adsorbed thorium from the resin by means of aqueous nitric acid. Thereafter the adsorbed protoactinium is eluted from the resin by means of an aqueous solution of ammonium fluoride.

  8. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brown, Garrett N.; Russell, Renee L.; Peterson, Reid A.

    This report summarizes the work performed to evaluate multiple, cesium loading, and elution cycles for small columns containing SRF resin using a simple, high-level waste (HLW) simulant. Cesium ion exchange loading and elution curves were generated for a nominal 5 M Na, 2.4E-05 M Cs, 0.115 M Al loading solution traced with 134Cs followed by elution with variable HNO3 (0.02, 0.07, 0.15, 0.23, and 0.28 M) containing variable CsNO3 (5.0E-09, 5.0E-08, and 5.0E-07 M) and traced with 137Cs. The ion exchange system consisted of a pump, tubing, process solutions, and a single, small ({approx}15.7 mL) bed of SRF resin withmore » a water-jacketed column for temperature-control. The columns were loaded with approximately 250 bed volumes (BVs) of feed solution at 45 C and at 1.5 to 12 BV per hour (0.15 to 1.2 cm/min). The columns were then eluted with 29+ BVs of HNO3 processed at 25 C and at 1.4 BV/h. The two independent tracers allowed analysis of the on-column cesium interaction between the loading and elution solutions. The objective of these tests was to improve the correlation between the spent resin cesium content and cesium leached out of the resin in subsequent loading cycles (cesium leakage) to help establish acid strength and purity requirements.« less

  9. Investigation of Processes Controlling Elution of Solutes from Nonaqueous Phase Liquid (NAPL) Pools into Groundwater

    NASA Astrophysics Data System (ADS)

    Seyedabbasi, M.; Pirestani, K.; Holland, S. B.; Imhoff, P. T.

    2005-12-01

    Two major processes influencing the elution of solutes from porous media contaminated with nonaqueous phase liquids (NAPLs) are external mass transfer between the NAPL and groundwater and internal diffusion through NAPL ganglia and pools. There is a relatively large body of literature on the dissolution of single-species NAPLs. Less is known about the rates of elution of compounds dissolving from multicomponent NAPLs. We examined the mass transfer of one solute, 2,3-dimethyl-2-butanol (DMB) - a partitioning tracer, between groundwater and a dense NAPL - trichloroethylene (TCE). Diffusion cell experiments were used to measure the molecular diffusion coefficient of DMB in pure TCE and in porous media contaminated with a TCE pool. Measured diffusion coefficients were compared with empirical correlations (pure TCE) and a parallel resistance model (TCE pool). Based on the results from these analyses, a dimensionless Biot number was derived to express the ratio of the external rate of mass transfer from a NAPL pool to the internal rate of diffusion within the pool, which varies with NAPL saturation and NAPL-water partition coefficient. Biot numbers were then estimated for several laboratory scale experiments involving DMB transport between NAPL pools and groundwater. The estimated Biot numbers were in good agreement with experimental results. The expression for the Biot number developed here may be used to assess the processes controlling the elution of solutes from NAPL pools, which has implications on long-term predictions of solute dissolution from NAPLs in the field.

  10. Innovative Elution Processes for Recovering Uranium and Transition Metals from Amidoxime-based Adsorbents

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wai, Chien M.

    Amidoxime-based polymer fibers are considered one of the most promising materials for sequestering uranium from seawater. The high-surface-area polymer fibers containing amidoxime and carboxylate groups synthesized by Oak Ridge National Lab (ORNL-AF1) show very high uranium adsorption capacities known in the literature. Effective elution of uranium and repeated use of the adsorbent are important factors affecting the cost of producing uranium from seawater using this material. Traditional acid leaching of uranium followed by KOH conditioning of the fiber causes chemical changes and physical damage to the ORNL-AF1 adsorbent. Two alkaline solution leaching methods were developed by this project, one usesmore » a highly concentrated (3 M) potassium bicarbonate solution at pH 8.3 and 40 °C; the other uses a mixture of sodium carbonate and hydrogen peroxide at pH 10.4. Both elution methods do not require KOH conditioning prior to reusing the fiber adsorbent. The conditions of eluting uranium from the amidoxime-based adsorbent using these alkaline solutions are confirmed by thermodynamic calculations. The bicarbonate elution method is selective for uranium recovery compared to other elution methods and causes no chemical change to the fiber material based on FTIR spectroscopy« less

  11. Concentration of perrhenate and pertechnetate solutions

    DOEpatents

    Knapp, F.F.; Beets, A.L.; Mirzadeh, S.; Guhlke, S.

    1998-03-17

    A method is described for preparing a concentrated solution of a carrier-free radioisotope which includes the steps of: (a) providing a generator column loaded with a composition containing a parent radioisotope; (b) eluting the generator column with an eluent solution which includes a salt of a weak acid to elute a target daughter radioisotope from the generator column in a first eluate; (c) eluting a cation-exchange column with the first eluate to exchange cations of the salt for hydrogen ions and to elute the target daughter radioisotope and a weak acid in a second eluate; (d) eluting an anion-exchange column with the second eluate to trap and concentrate the target daughter radioisotope and to elute the weak acid solution therefrom; and (e) eluting the concentrated target daughter radioisotope from the anion-exchange column with a saline solution. 1 fig.

  12. Concentration of perrhenate and pertechnetate solutions

    DOEpatents

    Knapp, Furn F.; Beets, Arnold L.; Mirzadeh, Saed; Guhlke, Stefan

    1998-01-01

    A method of preparing a concentrated solution of a carrier-free radioisotope which includes the steps of: a. providing a generator column loaded with a composition containing a parent radioisotope; b. eluting the generator column with an eluent solution which includes a salt of a weak acid to elute a target daughter radioisotope from the generator column in a first eluate. c. eluting a cation-exchange column with the first eluate to exchange cations of the salt for hydrogen ions and to elute the target daughter radioisotope and a weak acid in a second eluate; d. eluting an anion-exchange column with the second eluate to trap and concentrate the target daughter radioisotope and to elute the weak acid solution therefrom; and e. eluting the concentrated target daughter radioisotope from the anion-exchange column with a saline solution.

  13. Influence of amount of oxidizing slag discharged from stainless steelmaking process of electric arc furnace on elution behavior into fresh water

    NASA Astrophysics Data System (ADS)

    Yokoyama, S.; Shimomura, T.; Hisyamudin, M. N. N.; Takahashi, T.; Izaki, M.

    2012-03-01

    Fundamental study was carried out for provision for acidification of soil due to acid rain. The influence of weight of the additive slag on elution behavior of the slag into water was studied in this study. Elution experiment was carried out on a basis of JIS K 0058-1. Generally, the pH in the aqueous solution increased with an increase in weight of the additive slag. The pH converged to approximately eight. Calcium, magnesium and manganese, which were essential elements for plants, were eluted from the slag irrespective to elution condition. The eluted concentrations of Ca and Mg increased with an increase in weight of the additive slag. Silicon and zinc were also eluted depending on the conditions. Aluminum that was harmful for plants was not eluted from the used slag.

  14. Bicarbonate Elution of Uranium from Amidoxime-Based Polymer Adsorbents for Sequestering Uranium from Seawater

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pan, Horng-Bin; Wai, Chien M.; Kuo, Li-Jung

    Uranium adsorbed on amidoxime-based polyethylene fibers in simulated seawater can be quantitatively eluted using 3 M KHCO3 at 40°C. Thermodynamic calculations are in agreement with the experimental observation that at high bicarbonate concentrations (3 M) uranyl ions bound to amidoxime molecules are converted to uranyl tris-carbonato complex in the aqueous solution. The elution process is basically the reverse reaction of the uranium adsorption process which occurs at a very low bicarbonate concentration (~10-3 M) in seawater. In real seawater experiments, the bicarbonate elution is followed by a NaOH treatment to remove natural organic matter adsorbed on the polymer adsorbent. Usingmore » the sequential bicarbonate and NaOH elution, the adsorbent is reusable after rinsing with deionized water and the recycled adsorbent shows no loss of uranium loading capacity based on real seawater experiments.« less

  15. Bicarbonate Elution of Uranium from Amidoxime-Based Polymer Adsorbents for Sequestering Uranium from Seawater

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pan, Horng-Bin; Wai, Chien M.; Kuo, Li-Jung

    Uranium adsorbed on amidoxime-based polyethylene fibers in simulated seawater can be quantitatively eluted using 3 M KHCO 3 at 40°C. Thermodynamic calculations are in agreement with the experimental observation that at high bicarbonate concentrations (3 M) uranyl ions bound to amidoxime molecules are converted to uranyl tris-carbonato complex in the aqueous solution. The elution process is basically the reverse reaction of the uranium adsorption process which occurs at a very low bicarbonate concentration (~10 -3 M) in seawater. The bicarbonate elution is followed by a NaOH treatment to remove natural organic matter adsorbed on the polymer adsorbent, in real seawatermore » experiments. Furthermore, by using the sequential bicarbonate and NaOH elution, the adsorbent is reusable after rinsing with deionized water and the recycled adsorbent shows no loss of uranium loading capacity based on real seawater experiments.« less

  16. Bicarbonate Elution of Uranium from Amidoxime-Based Polymer Adsorbents for Sequestering Uranium from Seawater

    DOE PAGES

    Pan, Horng-Bin; Wai, Chien M.; Kuo, Li-Jung; ...

    2017-05-02

    Uranium adsorbed on amidoxime-based polyethylene fibers in simulated seawater can be quantitatively eluted using 3 M KHCO 3 at 40°C. Thermodynamic calculations are in agreement with the experimental observation that at high bicarbonate concentrations (3 M) uranyl ions bound to amidoxime molecules are converted to uranyl tris-carbonato complex in the aqueous solution. The elution process is basically the reverse reaction of the uranium adsorption process which occurs at a very low bicarbonate concentration (~10 -3 M) in seawater. The bicarbonate elution is followed by a NaOH treatment to remove natural organic matter adsorbed on the polymer adsorbent, in real seawatermore » experiments. Furthermore, by using the sequential bicarbonate and NaOH elution, the adsorbent is reusable after rinsing with deionized water and the recycled adsorbent shows no loss of uranium loading capacity based on real seawater experiments.« less

  17. CATIONIC EXCHANGE PROCESS FOR THE SEPARATION OF RARE EARTHS

    DOEpatents

    Choppin, G.R.; Thompson, S.G.; Harvey, B.G.

    1960-02-16

    A process for separating mixtures of elements in the lanthanum and actinium series of the periodic table is described. The mixture of elements is dissolved in 0.05 M HCI, wherein the elements exist as tripositive ions. The resulting solution is then transferred to a column of cationic exchange resin and the column eluted with 0.1 to 0.6 M aqueous ammonium alpha hydroxy isobutyrate solution of pH 3.8 to 5.0. The use of ammonium alpha hydroxy isobutyrate as an eluting agent results in sharper and more rapid separations than previously obtainable with eluants such as citric, tartaric, glycolic, and lactic acids.

  18. REMOVAL OF CESIUM BY SORPTION FROM AQUEOUS SOLUTIONS

    DOEpatents

    Ames, L.L.

    1962-01-16

    ABS>A process is given for selectively removing cesium from acid aqueous solutions containing cesium in microquantities and other cations in macroquantities by absorption on clinoptilolite. The cesium can be eluted from the clinoptilolite with a solution of ammonia, potassium hydroxide, or rubidium hydroxide. (AEC)

  19. Regeneration of pilot-scale ion exchange columns for hexavalent chromium removal.

    PubMed

    Korak, Julie A; Huggins, Richard; Arias-Paic, Miguel

    2017-07-01

    Due to stricter regulations, some drinking water utilities must implement additional treatment processes to meet potable water standards for hexavalent chromium (Cr(VI)), such as the California limit of 10 μg/L. Strong base anion exchange is effective for Cr(VI) removal, but efficient resin regeneration and waste minimization are important for operational, economic and environmental considerations. This study compared multiple regeneration methods on pilot-scale columns on the basis of regeneration efficiency, waste production and salt usage. A conventional 1-Stage regeneration using 2 N sodium chloride (NaCl) was compared to 1) a 2-Stage process with 0.2 N NaCl followed by 2 N NaCl and 2) a mixed regenerant solution with 2 N NaCl and 0.2 N sodium bicarbonate. All methods eluted similar cumulative amounts of chromium with 2 N NaCl. The 2-Stage process eluted an additional 20-30% of chromium in the 0.2 N fraction, but total resin capacity is unaffected if this fraction is recycled to the ion exchange headworks. The 2-Stage approach selectively eluted bicarbonate and sulfate with 0.2 N NaCl before regeneration using 2 N NaCl. Regeneration approach impacted the elution efficiency of both uranium and vanadium. Regeneration without co-eluting sulfate and bicarbonate led to incomplete uranium elution and potential formation of insoluble uranium hydroxides that could lead to long-term resin fouling, decreased capacity and render the resin a low-level radioactive solid waste. Partial vanadium elution occurred during regeneration due to co-eluting sulfate suppressing vanadium release. Waste production and salt usage were comparable for the 1- and 2-Stage regeneration processes with similar operational setpoints with respect to chromium or nitrate elution. Published by Elsevier Ltd.

  20. Immunoglobulin G elution in protein A chromatography employing the method of chromatofocusing for reducing the co-elution of impurities.

    PubMed

    Pinto, Nuno D S; Uplekar, Shaunak D; Moreira, Antonio R; Rao, Govind; Frey, Douglas D

    2017-01-01

    Purification processes for monoclonal Immunoglobulin G (IgG) typically employ protein A chromatography as a capture step to remove most of the impurities. One major concern of the post-protein A chromatography processes is the co-elution of some of the host cell proteins (HCPs) with IgG in the capture step. In this work, a novel method for IgG elution in protein A chromatography that reduces the co-elution of HCPs is presented where a two-step pH gradient is self-formed inside a protein A chromatography column. The complexities involved in using an internally produced pH gradient in a protein A chromatography column employing adsorbed buffering species are discussed though equation-based modeling. Under the conditions employed, ELISA assays show a 60% reduction in the HCPs co-eluting with the IgG fraction when using the method as compared to conventional protein A elution without affecting the IgG yield. Evidence is also obtained which indicates that the amount of leached protein A present in free solution in the purified product is reduced by the new method. Biotechnol. Bioeng. 2017;114: 154-162. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  1. LARGE SCALE METHOD FOR THE PRODUCTION AND PURIFICATION OF CURIUM

    DOEpatents

    Higgins, G.H.; Crane, W.W.T.

    1959-05-19

    A large-scale process for production and purification of Cm/sup 242/ is described. Aluminum slugs containing Am are irradiated and declad in a NaOH-- NaHO/sub 3/ solution at 85 to 100 deg C. The resulting slurry filtered and washed with NaOH, NH/sub 4/OH, and H/sub 2/O. Recovery of Cm from filtrate and washings is effected by an Fe(OH)/sub 3/ precipitation. The precipitates are then combined and dissolved ln HCl and refractory oxides centrifuged out. These oxides are then fused with Na/sub 2/CO/sub 3/ and dissolved in HCl. The solution is evaporated and LiCl solution added. The Cm, rare earths, and anionic impurities are adsorbed on a strong-base anfon exchange resin. Impurities are eluted with LiCl--HCl solution, rare earths and Cm are eluted by HCl. Other ion exchange steps further purify the Cm. The Cm is then precipitated as fluoride and used in this form or further purified and processed. (T.R.H.)

  2. TREATMENT FOR IMPROVING THE OPERATION OF STRONG BASE ANION EXCHANGE RESINS

    DOEpatents

    Stevenson, P.C.

    1960-11-29

    A process is offered for improving quaternary ammonium type strongly basic anion exchange resins so that centain zinc and cadmium residues, which normally stick to and "poison" this type of resin, can be removed by elution. Specifically, the resin as obtained commercially is treated with an aqueous solution of sodium hydroxide of about 1 to 4 M concentration by heating therein and periodically adding small amounts of oxidizing agent selected from hydrogen peroxide, sodium peroxide and hypochlorite. Zinc and cadmium values may then be adsorbed onto the resin from a 0.1 to 3 M HCl and thereafter eluted therefrom with very dilute HCl solutions.

  3. Radiopharmaceutical composition containing tantalum-178 and process therefor

    DOEpatents

    Neirinckx, Rudi D.; Holman, B. Leonard; Davis, Michael A.; Harris, Gale I.

    1989-05-16

    A physiologically acceptable solution of tantalum-178 having an activity of 0.1 to 200 millicuries per milliliter of tantalum-178 solution is provided. The solution is obtained from tungsten-178 bound to a column of an anion exchange resin which forms tantalum-178 in situ by eluting the column with a hydrochloric acid solution containing hydrogen peroxide to form an acidic solution of tantalum-178. The acidic solution of tantalum-178 then is neutralized.

  4. Expressions of the fundamental equation of gradient elution and a numerical solution of these equations under any gradient profile.

    PubMed

    Nikitas, P; Pappa-Louisi, A

    2005-09-01

    The original work carried out by Freiling and Drake in gradient liquid chromatography is rewritten in the current language of reversed-phase liquid chromatography. This allows for the rigorous derivation of the fundamental equation for gradient elution and the development of two alternative expressions of this equation, one of which is free from the constraint that the holdup time must be constant. In addition, the above derivation results in a very simple numerical solution of the various equations of gradient elution under any gradient profile. The theory was tested using eight catechol-related solutes in mobile phases modified with methanol, acetonitrile, or 2-propanol. It was found to be a satisfactory prediction of solute gradient retention behavior even if we used a simple linear description for the isocratic elution of these solutes.

  5. Development of a high performance (188)W/(188)Re generator by using a synthetic alumina.

    PubMed

    Lee, Jun Sig; Lee, Jong-Soup; Park, Ul-Jae; Son, Kwang-Jae; Han, Hyon-Soo

    2009-01-01

    A synthetic alumina functionalized with a sulfate moiety has been developed as the column material of (99)Mo/(99m)Tc and (188)W/(188)Re generators. This material is synthesized by a sol-gel processing. In order to characterize the adsorbent for the (188)W/(188)Re separation, both batch and column contact experiments were conducted. As a result of the experiments, it is found that the maximum capacity of the adsorbent for tungsten is higher than 450mg/g. Hence it is possible to produce approximately 3Ci (188)W/(188)Re generator with only 1g of the adsorbent from (188)W solutions supplied from ORNL, USA or RIAR, Russia. A demonstration study was conducted to show the performance of an (188)W/(188)Re generator column. In this study, 1Ci of (188)W purchased from RIAR, Russia, is loaded on a 0.9cm ID column packed with 0.7g of the adsorbent. Elution of (188)Re is performed every 4-7 days by using the saline solution for more than three months. Nearly 100% of tungsten is loaded by passing 5ml of the (188)W solution (pH=8) through the dry packed column at a 1ml/min flow rate. Elution efficiency of (188)Re is 70-90% by using 5ml of the saline solution. The ratio of (188)W/(188)Re in the eluted solution is 0.002-0.003%. When a Sep-Pak containing 0.26g of acid alumina is installed as a tandem column, the ratio is decreased to less than 10(-3)%. Thin layer chromatography for the eluted (188)Re solution shows 100% radiochemical purity. Also, alumina content in the eluted solution shows less than 10ppm. Through this study, the performance of this adsorbent was successfully demonstrated. By using the developed adsorbent, minimization of the generator column and consequently the volume of eluant could be possible while maintaining the quality of (188)Re just as much as that available in the market.

  6. Application of acidic elution to virus concentration using electropositive filters.

    PubMed

    Haramoto, Eiji; Katayama, Hiroyuki

    2013-03-01

    The effect of the type and pH of an elution solution on the recovery of poliovirus from water by a virus concentration method using an electropositive filter was evaluated. The experimental results obtained indicated the potential usefulness of H2SO4 (pH 1.5-3.5) as a novel solution for virus elution.

  7. METHOD OF SEPARATING RARE EARTHS BY ION EXCHANGE

    DOEpatents

    Spedding, F.H.; Powell, J.E.

    1960-10-18

    A process is given for separating yttrium and rare earth values having atomic numbers of from 57 through 60 and 68 through 71 from an aqueous solution whose pH value can range from 1 to 9. All rare earths and yttrium are first adsorbed on a cation exchange resin, and they are then eluted with a solution of N-hydroxyethylethylenediaminetriacetic acid (HEDTA) in the order of decreasing atomic number, yttrium behaving like element 61; the effluents are collected in fractions. The HEDTA is recovered by elution with ammonia solution and the resin is regenerated with sulfuric acid. Rare earths are precipitated from the various effluents with oxalic acid, and each supernatant is passed over cation exchange resin for adsorption of HEDTA and nonprecipitated rare earths: the oxalic acid is not retained by the resin.

  8. Aluminum elution and precipitation in glass vials: effect of pH and buffer species.

    PubMed

    Ogawa, Toru; Miyajima, Makoto; Wakiyama, Naoki; Terada, Katsuhide

    2015-02-01

    Inorganic extractables from glass vials may cause particle formation in the drug solution. In this study, the ability of eluting Al ion from borosilicate glass vials, and tendencies of precipitation containing Al were investigated using various pHs of phosphate, citrate, acetate and histidine buffer. Through heating, all of the buffers showed that Si and Al were eluted from glass vials in ratios almost the same as the composition of borosilicate glass, and the amounts of Al and Si from various buffer solutions at pH 7 were in the following order: citrate > phosphate > acetate > histidine. In addition, during storage after heating, the Al concentration at certain pHs of phosphate and acetate buffer solution decreased, suggesting the formation of particles containing Al. In citrate buffer, Al did not decrease in spite of the high elution amount. Considering that the solubility profile of aluminum oxide and the Al eluting profile of borosilicate glass were different, it is speculated that Al ion may be forced to leach into the buffer solution according to Si elution on the surface of glass vials. When Al ions were added to the buffer solutions, phosphate, acetate and histidine buffer showed a decrease of Al concentration during storage at a neutral range of pHs, indicating the formation of particles containing Al. In conclusion, it is suggested that phosphate buffer solution has higher possibility of forming particles containing Al than other buffer solutions.

  9. Separation and Recovery of Cobalt from Copper Leach Solutions

    NASA Astrophysics Data System (ADS)

    Jeffers, T. H.

    1985-01-01

    Significant amounts of cobalt, a strategic and critical metal, are present in readily accessible copper recycling leach solutions. However, cost-effective technology is not available to separate and recover the cobalt from this low-grade domestic source. The Bureau of Mines has developed a procedure using a chelating ion-exchange resin from Dow Chemical Co. to successfully extract cobalt from a pH 3.0 copper recycling solution containing only 30 mg/1 cobalt. Cyclic tests with the commercial resin XFS-4195 in 4-ft-high by 1-in.-diameter columns gave an average cobalt extraction of 95% when 65 bed volumes of solution were processed at a flow rate of 4 gpm/ft.2 Elution of the cobalt using a 50 g/l H2SO4 solution yielded an eluate containing 0.5 gli Co. Selective elution of the loaded resin and solvent extraction procedures using di-2-ethylhexyl phosphoric acid (D2EHPA) and Cyanex 272 removed the impurities and produced a cobalt sulfate solution containing 25 g/l Co.

  10. Separation of thorium and uranium in nitric acid solution using silica based anion exchange resin.

    PubMed

    Chen, Yanliang; Wei, Yuezhou; He, Linfeng; Tang, Fangdong

    2016-09-30

    To separate thorium and uranium in nitric acid solution using anion exchange process, a strong base silica-based anion exchange resin (SiPyR-N4) was synthesized. Batch experiments were conducted and the separation factor of thorium and uranium in 9M nitric acid was about 10. Ion exchange chromatography was applied to separate thorium and uranium in different ratios. Uranium could be eluted by 9M nitric acid and thorium was eluted by 0.1M nitric acid. It was proved that thorium and uranium can be separated and recovered successfully by this method. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Carbonate-H2O2 Leaching for Sequestering Uranium from Seawater

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pan, Horng-Bin; Weisheng, Liao; Wai, Chien

    Uranium adsorbed on amidoxime-based polyethylene fiber in simulated seawater can be quantitatively eluted at room temperature using 1M Na2CO3 containing 0.1 M H2O2. This efficient elution process is probably due to formation of an extremely stable uranyl-peroxo-carbonato complex in the carbonate solution. After washing with water, the sorbent can be reused with little loss of uranium loading capacity. Possible existence of this stable uranyl species in ocean water is also discussed.

  12. Carbonate-H₂O₂ leaching for sequestering uranium from seawater.

    PubMed

    Pan, Horng-Bin; Liao, Weisheng; Wai, Chien M; Oyola, Yatsandra; Janke, Christopher J; Tian, Guoxin; Rao, Linfeng

    2014-07-28

    Uranium adsorbed on amidoxime-based polyethylene fiber in simulated seawater can be quantitatively eluted at room temperature using 1 M Na2CO3 containing 0.1 M H2O2. This efficient elution process is probably due to the formation of an extremely stable uranyl-peroxo-carbonato complex in the carbonate solution. After washing with water, the sorbent can be reused with minimal loss of uranium loading capacity. Possible existence of this stable uranyl species in ocean water is also discussed.

  13. Time-Fractional Advection-Dispersion Equation (tFADE) to Quantify Aqueous Phase Contaminant Elution from a Trichloroethene (TCE) NAPL Source Zone in Sand Columns

    NASA Astrophysics Data System (ADS)

    Tick, G. R.; Wei, S.; Sun, H.; Zhang, Y.

    2016-12-01

    Pore-scale heterogeneity, NAPL distribution, and sorption/desorption processes can significantly affect aqueous phase elution and mass flux in porous media systems. The application of a scale-independent fractional derivative model (tFADE) was used to simulate elution curves for a series of columns (5 cm, 7 cm, 15 cm, 25 cm, and 80 cm) homogeneously packed with 20/30-mesh sand and distributed with uniform saturations (7-24%) of NAPL phase trichloroethene (TCE). An additional set of columns (7 cm and 25 cm) were packed with a heterogeneous distribution of quartz sand upon which TCE was emplaced by imbibing the immiscible liquid, under stable displacement conditions, to simulate a spill-type process. The tFADE model was able to better represent experimental elution behavior for systems that exhibited extensive long-term concentration tailing requiring much less parameters compared to typical multi-rate mass transfer models (MRMT). However, the tFADE model was not able to effectively simulate the entire elution curve for such systems with short concentration tailing periods since it assumes a power-law distribution for the dissolution rate for TCE. Such limitations may be solved using the tempered fractional derivative model, which can capture the single-rate mass transfer process and therefore the short elution concentration tailing behavior. Numerical solution for the tempered fractional-derivative model in bounded domains however remains a challenge and therefore requires further study. However, the tFADE model shows excellent promise for understanding impacts on concentration elution behavior for systems in which physical heterogeneity, non-uniform NAPL distribution, and pronounced sorption-desorption effects dominate or are present.

  14. Technetium-99m generator system

    DOEpatents

    Mirzadeh, Saed; Knapp, Jr., Furn F.; Collins, Emory D.

    1998-01-01

    A .sup.99 Mo/.sup.99m Tc generator system includes a sorbent column loaded with a composition containing .sup.99 Mo. The sorbent column has an effluent end in fluid communication with an anion-exchange column for concentrating .sup.99m Tc eluted from the sorbent column. A method of preparing a concentrated solution of .sup.99m Tc includes the general steps of: a. providing a sorbent column loaded with a composition containing .sup.99 Mo, the sorbent column having an effluent end in fluid communication with an anion-exchange column; b. eluting the sorbent column with a salt solution to elute .sup.99m Tc from the sorbent and to trap and concentrate the eluted .sup.99m Tc on the ion-exchange column; and c. eluting the concentrated .sup.99m Tc from the ion-exchange column with a solution comprising a reductive complexing agent.

  15. Technetium-99m generator system

    DOEpatents

    Mirzadeh, S.; Knapp, F.F. Jr.; Collins, E.D.

    1998-06-30

    A {sup 99}Mo/{sup 99m}Tc generator system includes a sorbent column loaded with a composition containing {sup 99}Mo. The sorbent column has an effluent end in fluid communication with an anion-exchange column for concentrating {sup 99m}Tc eluted from the sorbent column. A method of preparing a concentrated solution of {sup 99m}Tc includes the general steps of: (a) providing a sorbent column loaded with a composition containing {sup 99}Mo, the sorbent column having an effluent end in fluid communication with an anion-exchange column; (b) eluting the sorbent column with a salt solution to elute {sup 99m}Tc from the sorbent and to trap and concentrate the eluted {sup 99m}Tc on the ion-exchange column; and (c) eluting the concentrated {sup 99m}Tc from the ion-exchange column with a solution comprising a reductive complexing agent. 1 fig.

  16. Retention prediction of highly polar ionizable solutes under gradient conditions on a mixed-mode reversed-phase and weak anion-exchange stationary phase.

    PubMed

    Balkatzopoulou, P; Fasoula, S; Gika, H; Nikitas, P; Pappa-Louisi, A

    2015-05-29

    In the present work the retention of three highly polar and ionizable solutes - uric acid, nicotinic acid and ascorbic acid - was investigated on a mixed-mode reversed-phase and weak anion-exchange (RP/WAX) stationary phase in buffered aqueous acetonitrile (ACN) mobile phases. A U-shaped retention behavior was observed for all solutes with respect to the eluent organic modifier content studied in a range of 5-95% (v/v). This retention behavior clearly demonstrates the presence of a HILIC-type retention mechanism at ACN-rich hydro-organic eluents and an RP-like retention at aqueous-rich hydro-organic eluents. Hence, this column should be promising for application under both RP and HILIC gradient elution modes. For this reason, a series of programmed elution runs were carried out with increasing (RP) and decreasing (HILIC) organic solvent concentration in the mobile phase. This dual gradient process was successfully modeled by two retention models exhibiting a quadratic or a cubic dependence of the logarithm of the solute retention factor (lnk) upon the organic modifier volume fraction (φ). It was found that both models produced by gradient retention data allow the prediction of solute retention times for both types of programmed elution on the mixed-mode column. Four, in the case of the quadratic model, or five, in the case of the cubic model, initial HILIC- and RP-type gradient runs gave satisfactory retention predictions of any similar kind elution program, even with different flow rate, with an overall error of only 2.5 or 1.7%, respectively. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. [Fast optimization of stepwise gradient conditions for ternary mobile phase in reversed-phase high performance liquid chromatography].

    PubMed

    Shan, Yi-chu; Zhang, Yu-kui; Zhao, Rui-huan

    2002-07-01

    In high performance liquid chromatography, it is necessary to apply multi-composition gradient elution for the separation of complex samples such as environmental and biological samples. Multivariate stepwise gradient elution is one of the most efficient elution modes, because it combines the high selectivity of multi-composition mobile phase and shorter analysis time of gradient elution. In practical separations, the separation selectivity of samples can be effectively adjusted by using ternary mobile phase. For the optimization of these parameters, the retention equation of samples must be obtained at first. Traditionally, several isocratic experiments are used to get the retention equation of solute. However, it is time consuming especially for the separation of complex samples with a wide range of polarity. A new method for the fast optimization of ternary stepwise gradient elution was proposed based on the migration rule of solute in column. First, the coefficients of retention equation of solute are obtained by running several linear gradient experiments, then the optimal separation conditions are searched according to the hierarchical chromatography response function which acts as the optimization criterion. For each kind of organic modifier, two initial linear gradient experiments are used to obtain the primary coefficients of retention equation of each solute. For ternary mobile phase, only four linear gradient runs are needed to get the coefficients of retention equation. Then the retention times of solutes under arbitrary mobile phase composition can be predicted. The initial optimal mobile phase composition is obtained by resolution mapping for all of the solutes. A hierarchical chromatography response function is used to evaluate the separation efficiencies and search the optimal elution conditions. In subsequent optimization, the migrating distance of solute in the column is considered to decide the mobile phase composition and sustaining time of the latter steps until all the solutes are eluted out. Thus the first stepwise gradient elution conditions are predicted. If the resolution of samples under the predicted optimal separation conditions is satisfactory, the optimization procedure is stopped; otherwise, the coefficients of retention equation are adjusted according to the experimental results under the previously predicted elution conditions. Then the new stepwise gradient elution conditions are predicted repeatedly until satisfactory resolution is obtained. Normally, the satisfactory separation conditions can be found only after six experiments by using the proposed method. In comparison with the traditional optimization method, the time needed to finish the optimization procedure can be greatly reduced. The method has been validated by its application to the separation of several samples such as amino acid derivatives, aromatic amines, in which satisfactory separations were obtained with predicted resolution.

  18. Improved production and processing of ⁸⁹Zr using a solution target.

    PubMed

    Pandey, Mukesh K; Bansal, Aditya; Engelbrecht, Hendrik P; Byrne, John F; Packard, Alan B; DeGrado, Timothy R

    2016-01-01

    The objectives of the present work were to improve the cyclotron production yield of (89)Zr using a solution target, develop a practical synthesis of the hydroxamate resin used to process the target, and develop a biocompatible medium for (89)Zr elution from the hydroxamate resin. A new solution target (BMLT-2) with enhanced heat dissipation capabilities was designed by using helium-cooled dual foils (0.2 mm Al and 25 μ Havar) and an enhanced water-cooled, elongated solution cavity in the target insert. Irradiations were performed with 14 MeV protons on a 2M solution of yttrium nitrate in 1.25 M nitric acid at 40-μA beam current for 2 h in a closed system. Zirconium-89 was separated from Y by use of a hydroxamate resin. A one-pot synthesis of hydroxamate resin was accomplished by activating the carboxylate groups on a carboxymethyl cation exchange resin using methyl chloroformate followed by reaction with hydroxylamine hydrochloride. After trapping of (89)Zr on hydroxamate resin and rinsing the resin with HCl and water to release Y, (89)Zr was eluted with 1.2 M K2HPO4/KH2PO4 buffer (pH3.5). ICP-MS was used to measure metal contaminants in the final (89)Zr solution. The BMLT-2 target produced 349±49 MBq (9.4±1.2 mCi) of (89)Zr at the end of irradiation with a specific activity of 1.18±0.79 GBq/μg. The hydroxamate resin prepared using the new synthesis method showed a trapping efficiency of 93% with a 75 mg resin bed and 96-97% with a 100-120 mg resin bed. The elution efficiency of (89)Zr with 1.2M K2HPO4/KH2PO4 solution was found to be 91.7±3.7%, compared to >95% for 1 M oxalic acid. Elution with phosphate buffer gave very small levels of metal contaminants: Al=0.40-0.86 μg (n=2), Fe=1.22±0.71 μg (n=3), Y=0.29 μg (n=1). The BMLT-2 target allowed doubling of the beam current for production of (89)Zr, resulting in a greater than 2-fold increase in production yield in comparison with a conventional liquid target. The new one-pot synthesis of hydroxamate resin provides a simpler synthesis method for the (89)Zr trapping resin. Finally, phosphate buffer elutes the (89)Zrfrom the hydroxamate resin in high efficiency while at the same time providing a more biocompatible medium for subsequent use of (89)Zr. Copyright © 2015 Elsevier Inc. All rights reserved.

  19. COLUMBIC OXIDE ADSORPTION PROCESS FOR SEPARATING URANIUM AND PLUTONIUM IONS

    DOEpatents

    Beaton, R.H.

    1959-07-14

    A process is described for separating plutonium ions from a solution of neutron irradiated uranium in which columbic oxide is used as an adsorbert. According to the invention the plutonium ion is selectively adsorbed by Passing a solution containing the plutonium in a valence state not higher than 4 through a porous bed or column of granules of hydrated columbic oxide. The adsorbed plutonium is then desorbed by elution with 3 N nitric acid.

  20. Counter-current chromatography: simple process and confusing terminology.

    PubMed

    Conway, Walter D

    2011-09-09

    The origin of counter-current chromatography is briefly stated, followed by a description of the mechanism of elution of solutes, which illustrates the elegance and simplicity of the technique. The CCC retention equation can be mentally derived from three facts; that a substance with a distribution coefficient of 0 elutes at the mobile phase solvent front (one mobile phase volume); and one with a distribution coefficient of 1 elutes at the column volume of mobile phase; and solutes with higher distribution coefficients elute at additional multiples of the stationary phase volume. The pattern corresponds to the classical solute retention equation for chromatography, V(R)=V(M)+K(C)V(S), K(C) not being limited to integer values. This allows the entire pattern of solute retention to be visualized on the chromatogram. The high volume fraction of stationary phase in CCC greatly enhances resolution. A survey of the names, symbols and definitions of several widely used chromatography and liquid-liquid distribution parameters in the IUPAC Gold Book and in a recent summary in LC-GC by Majors and Carr revealed numerous conflicts in both names and definitions. These will retard accurate dissemination of CCC research unless the discordance is resolved. It is proposed that the chromatography retention parameter, K(C), be called the distribution coefficient and that a new biphasic distribution parameter, K(Δ(A)), be defined for CCC and be called the species partition ratio. The definition of V(M) should be clarified. V(H) is suggested to represent the holdup volume and V(X) is suggested for the extra-column volume. H(V) and H(L) are suggested to represent the volume and length of a theoretical plate in CCC. Definitions of the phase ratio, β, conflict and should be clarified. Copyright © 2011 Elsevier B.V. All rights reserved.

  1. Process for removing metals from water

    DOEpatents

    Napier, John M.; Hancher, Charles M.; Hackett, Gail D.

    1989-01-01

    A process for removing metals from water including the steps of prefiltering solids from the water, adjusting the pH to between about 2 and 3, reducing the amount of dissolved oxygen in the water, increasing the pH to between about 6 and 8, adding water-soluble sulfide to precipitate insoluble sulfide- and hydroxide-forming metals, adding a flocculating agent, separating precipitate-containing floc, and postfiltering the resultant solution. The postfiltered solution may optionally be eluted through an ion exchange resin to remove residual metal ions.

  2. Process for removing metals from water

    DOEpatents

    Napier, J.M.; Hancher, C.M.; Hackett, G.D.

    1987-06-29

    A process for removing metals from water including the steps of prefiltering solids from the water, adjusting the pH to between about 2 and 3, reducing the amount of dissolved oxygen in the water, increasing the pH to between about 6 and 8, adding water-soluble sulfide to precipitate insoluble sulfide- and hydroxide-forming metals, adding a containing floc, and postfiltering the resultant solution. The postfiltered solution may optionally be eluted through an ion exchange resin to remove residual metal ions. 2 tabs.

  3. [Application of general retention time formula for gradient liquid chromatography in the studies of ladder-like gradient elution].

    PubMed

    Sun, Xiaoli; Hao, Weiqiang; Wang, Junde; Di, Bin; Chen, Qiang; Zhuang, Wei; Yu, Qiang; Zhang, Peipei

    2013-08-01

    By not explicitly specifying the type of solvent strength model, the features of ladder-like gradient elution were studied based on the general retention time formula that was derived in our previous work. For the case where the solute is eluted at like gradient, we derived the expression that connects the mobile phase composition (phiR), at which the solute is eluted from the column, with the gradient slope (B). It was shown that phiR will increase with the increase of B in this case. For the case where the solute is eluted at the last isocratic segment of the ladder-like gradient, it was proven that the retention time (tR) will correlate linearly with the reciprocal of the gradient slope (1/B) when the initial and final mobile phase compositions are set to be constant. In experiments, by taking biphenyl as the sample, the values of retention time in isocratic and gradient elution were measured on a C18 column by using a mixture of methanol and water as the mobile phase. The experimental values were found to be well consistent with the theoretical values that were calculated from the expressions. These expressions will be helpful to understand the features of the ladder-like gradient in practice.

  4. Liquid-liquid phase separation causes high turbidity and pressure during low pH elution process in Protein A chromatography.

    PubMed

    Luo, Haibin; Lee, Nacole; Wang, Xiangyang; Li, Yuling; Schmelzer, Albert; Hunter, Alan K; Pabst, Timothy; Wang, William K

    2017-03-10

    Turbid elution pools and high column back pressure are common during elution of monoclonal antibodies (mAbs) by acidic pH in Protein A chromatography. This phenomenon has been historically attributed to acid-induced precipitation of incorrectly folded or pH-sensitive mAbs and host cell proteins (HCPs). In this work, we propose a new mechanism that may account for some observations of elution turbidity in Protein A chromatography. We report several examples of turbidity and high column back pressure occurring transiently under a short course of neutral conditions during Protein A elution. A systematic study of three mAbs displaying this behavior revealed phase separation characterized by liquid drops under certain conditions including neutral pH, low ionic strength, and high protein concentration. These liquid droplets caused solution turbidity and exhibited extremely high viscosity, resulting in high column back pressure. We found out that the droplets were formed through liquid-liquid phase separation (LLPS) as a result of protein self-association. We also found multiple factors, including pH, temperature, ionic strength, and protein concentration can affect LLPS behaviors. Careful selection of process parameters during protein A elution, including temperature, flow rate, buffer, and salt can inhibit formation of a dense liquid phase, reducing both turbidity (by 90%) and column back pressure (below 20 pounds per square inch). These findings provide both mechanistic insight and practical mitigation strategies for Protein A chromatography induced LLPS. Copyright © 2017 The Author(s). Published by Elsevier B.V. All rights reserved.

  5. Method for regeneration of electroless nickel plating solution

    DOEpatents

    Eisenmann, Erhard T.

    1997-01-01

    An electroless nickel(EN)/hypophosphite plating bath is provided employing acetic acid/acetate as a buffer and which is, as a result, capable of perpetual regeneration while avoiding the production of hazardous waste. A regeneration process is provided to process the spent EN plating bath solution. A concentrated starter and replenishment solution is provided for ease of operation of the plating bath. The regeneration process employs a chelating ion exchange system to remove nickel cations from spent EN plating solution. Phosphites are then removed from the solution by precipitation. The nickel cations are removed from the ion exchange system by elution with hypophosphorous acid and the nickel concentration of the eluate adjusted by addition of nickel salt. The treated solution and adjusted eluate are combined, stabilizer added, and the volume of resulting solution reduced by evaporation to form the bath starter and replenishing solution.

  6. Method for regeneration of electroless nickel plating solution

    DOEpatents

    Eisenmann, E.T.

    1997-03-11

    An electroless nickel(EN)/hypophosphite plating bath is provided employing acetic acid/acetate as a buffer and which is, as a result, capable of perpetual regeneration while avoiding the production of hazardous waste. A regeneration process is provided to process the spent EN plating bath solution. A concentrated starter and replenishment solution is provided for ease of operation of the plating bath. The regeneration process employs a chelating ion exchange system to remove nickel cations from spent EN plating solution. Phosphites are then removed from the solution by precipitation. The nickel cations are removed from the ion exchange system by elution with hypophosphorus acid and the nickel concentration of the eluate adjusted by addition of nickel salt. The treated solution and adjusted eluate are combined, stabilizer added, and the volume of resulting solution reduced by evaporation to form the bath starter and replenishing solution. 1 fig.

  7. BARIUM RECOVERY PROCESS

    DOEpatents

    Blanco, R.E.

    1959-07-21

    A method of separating barium from nuclear fission products is described. In accordance with the invention, barium may be recovered from an acidic solution of neutron-irradiated fissionable material by carrying ihe barium cut of solution as a sulfate with lead as a carrier and then dissolving the barium-containing precipitate in an aqueous solution of an aliphatic diamine chelating reagent. The barium values together with certain other metallic values present in the diamine solution are then absorbed onto a cation exchange resin and the barium is selectively eluted from the resin bed with concentrated nitric acid.

  8. Recovery of boric acid from ion exchangers

    DOEpatents

    Pollock, Charles W.

    1976-01-01

    The recovery of boric acid from an anion exchange resin is improved by eluting the boric acid with an aqueous solution of ammonium bicarbonate. The boric acid can be readily purified and concentrated by distilling off the water and ammonium bicarbonate. This process is especially useful for the recovery of boric acid containing a high percentage of .sup.10 B which may be found in some nuclear reactor coolant solutions.

  9. Method for aqueous gold thiosulfate extraction using copper-cyanide pretreated carbon adsorption

    DOEpatents

    Young, Courtney; Melashvili, Mariam; Gow, Nicholas V

    2013-08-06

    A gold thiosulfate leaching process uses carbon to remove gold from the leach liquor. The activated carbon is pretreated with copper cyanide. A copper (on the carbon) to gold (in solution) ratio of at least 1.5 optimizes gold recovery from solution. To recover the gold from the carbon, conventional elution technology works but is dependent on the copper to gold ratio on the carbon.

  10. Use of laterite for the removal of fluoride from contaminated drinking water.

    PubMed

    Sarkar, Mitali; Banerjee, Aparna; Pramanick, Partha Pratim; Sarkar, Asit R

    2006-10-15

    The effects of different operational variables on the mechanistic function of laterite in removal of fluoride have been investigated. Thermodynamic parameters such as free energy change, enthalpy, and entropy of the process, as well as the sorption isotherm, were evaluated. The extent of solute removal is determined by initial solute concentration, operational conditions, laterite dose, and solution pH. For a fixed set of experimental conditions, a model equation is developed from which the percent removal corresponding to each load of fluoride is determined. The mechanism of fluoride adsorption is governed by the zero point charge of laterite and follows a first-order rate equation. pH has a vital role influencing the surface characteristics of laterite. To simulate the flow dynamics, fluoride solution was run through a fixed bed column. The pattern of breakthrough curves for different influent fluoride concentration, pH, and column bed height was characterized. The column efficiency was tested from the bed depth-service time model. The elution of the retained fluoride was studied and the effectiveness of column operation was determined by the retention-elution cycles.

  11. CATION EXCHANGE METHOD FOR THE RECOVERY OF PROTACTINIUM

    DOEpatents

    Studier, M.H.; Sullivan, J.C.

    1959-07-14

    A cation exchange prccess is described for separating protactinium values from thorium values whereby they are initially adsorbed together from an aqueous 0.1 to 2 N hydrochloric acid on a cation exchange resin in a column. Then selectively eluting the thorium by an ammonium sulfate solution and subsequently eluting the protactinium by an oxalate solution.

  12. PROCESS OF PRODUCING Cm$sup 244$ AND Cm$sup 24$$sup 5$

    DOEpatents

    Manning, W.M.; Studier, M.H.; Diamond, H.; Fields, P.R.

    1958-11-01

    A process is presented for producing Cm and Cm/sup 245/. The first step of the process consists in subjecting Pu/sup 2339/ to a high neutron flux and subsequently dissolving the irradiated material in HCl. The plutonium is then oxidized to at least the tetravalent state and the solution is contacted with an anion exchange resin, causing the plutonium values to be absorbed while the fission products and transplutonium elements remain in the effluent solution. The effluent solution is then contacted with a cation exchange resin causing the transplutonium, values to be absorbed while the fission products remain in solution. The cation exchange resin is then contacted with an aqueous citrate solution and tbe transplutonium elements are thereby differentially eluted in order of decreasing atomic weight, allowing collection of the desired fractions.

  13. Preparative electrophoresis with on-column optical fiber monitoring and direct elution into a minimized volume.

    PubMed

    Jackson, George W; Willson, Richard

    2005-11-01

    A "column-format" preparative electrophoresis device which obviates the need for gel extraction or secondary electro-elution steps is described. Separated biomolecules are continuously detected and eluted directly into a minimal volume of free solution for subsequent use. An optical fiber allows the species of interest to be detected just prior to elution from the gel column, and a small collection volume is created by addition of an ion-exchange membrane near the end of the column.

  14. ION EXCHANGE PROCESS FOR THE RECOVERY AND PURIFICATION OF MATERIALS

    DOEpatents

    Long, R.S.; Bailes, R.H.

    1958-04-15

    A process for the recovery of certain metallic ions from aqueous solutions by ion exchange techniques is described. It is applicable to elements such as vanadium, chromium, nnanganese, and the like, which are capable of forming lower valent cations soluble in aqueous solutions and which also form ldgher valent anions soluble in aqueous acidic solutions. For example, small amounts of vanadium occurring in phosphoric acid prepared from phosphate rock may be recovered by reducing the vanadium to a trivalent cation adsorbing; the vanadium in a cationic exchange resin, then treating the resin with a suitable oxidizing agent to convert the adsorbed vanadium to a higher valent state, and finally eluting; the vanadium as an anion from the resin by means of an aqueous acidic solution.

  15. Elution of lead from lead zirconate titanate ceramics to acid rain

    NASA Astrophysics Data System (ADS)

    Tsurumi, Takaaki; Takezawa, Shuhei; Hoshina, Takuya; Takeda, Hiroaki

    2017-10-01

    The amount of lead that eluted from lead zirconate titanate (PZT) ceramics to artificial acid rain was evaluated. Four kinds of PZT ceramics, namely, pure PZT at MPB composition, CuO-added PZT, PZT with 10 mol % substitution of Ba for Pb, and CuO-added PZT with 10 mol % substitution of Ba for Pb, were used as samples of the elution test. These PZT ceramics of 8 mm2 and 1.1-1.2 mm thickness were suspended in 300 ml of H2SO4 solution of pH 4.0. The concentration of lead eluted from PZT was in the range from 0.2 to 0.8 ppm. It was found that both liquid phase formation by the addition of CuO and the substitution of Ba for Pb were effective to reduce the amount of lead that eluted. By fitting the leaching out curve with a classical equation, a master curve assuming no sampling effect was obtained. The lead concentration evaluated from the amount of lead that eluted from a commercial PZT plate to H2SO4 solution of pH 5.3 was almost the same as the limit in city water. It is concluded that PZT is not harmful to health and the environment and the amount of lead that eluted from PZT can be controlled by modifying PZT composition.

  16. URANIUM RECOVERY AND PURIFICATION PROCESS AND PRODUCTION OF HIGH PURITY URANIUM TETRAFLUORIDE

    DOEpatents

    Bailes, R.H.; Long, R.S.; Grinstead, R.R.

    1957-09-17

    A process is described wherein an anionic exchange technique is employed to separate uramium from a large variety of impurities. Very efficient and economical purification of contamimated uranium can be achieved by treatment of the contaminated uranium to produce a solution containing a high concentration of chloride. Under these conditions the uranium exists as an aniomic chloride complex. Then the uranium chloride complex is adsorbed from the solution on an aniomic exchange resin, whereby a portion of the impurities remain in the solution and others are retained with the uramium by the resin. The adsorbed impurities are then removed by washing the resin with pure concentrated hydrochloric acid, after which operation the uranium is eluted with pure water yielding an acidic uranyl chloride solution of high purity.

  17. Ultrasonic atomization and subsequent desolvation for monoclonal antibody (mAb) to the glycoprotein (GP) IIIa receptor into drug eluting stent.

    PubMed

    Wang, G X; Luo, L L; Yin, T Y; Li, Y; Jiang, T; Ruan, C G; Guidoin, R; Chen, Y P; Guzman, R

    2010-01-01

    An eluting-stent system with mAb dispersed in the PLLA (poly (L-lactic acid)) was validated in vitro. Specifically designed spray equipment based on the principle of ultrasonic atomization was used to produce a thin continuous PLLA (poly (L-lactic acid)) polymer coating incorporating monoclonal antibody (mAb). This PLLA coating was observed in light microscopy (LM) and scanning electron microscopy (SEM). The concentration of the monoclonal antibody (mAb) to the platelet glycoprotein (GP) IIIa receptor and the eluting rate were then measured by a radioisotope technique with (125)I-labelled GP IIIa mAb. An in vitro perfusion circuit was designed to evaluate the release rates at different velocities (10 or 20 ml min(-1)). The PLLA coating was thin and transparent, uniformly distributed on the surface of the stent. Three factors influenced its thickness: PLLA concentration, duration and gas pressure. The concentration of mAb was influenced by the duration of absorption and the concentration of the mAb solution; the maximum was 1662.23 + or - 38.83 ng. The eluting rate was fast for the first 2 h, then decreased slowly and attained 80% after 2 weeks. This ultrasonic atomization spray equipment and technological process to prepare protein eluting-stents were proved to be effective and reliable.

  18. Leach of the weathering crust elution-deposited rare earth ore for low environmental pollution with a combination of (NH4)2SO4 and EDTA.

    PubMed

    Tang, Jie; Qiao, Jiyang; Xue, Qiang; Liu, Fei; Chen, Honghan; Zhang, Guochen

    2018-05-01

    High concentration of ammonium sulfate, a typical leaching agent, was often used in the mining process of the weathering crust elution-deposited rare earth ore. After mining, a lot of ammonia nitrogen and labile heavy metal fractions were residual in tailings, which may result in a huge potential risk to the environment. In this study, in order to achieve the maximum extraction of rare earth elements and reduce the labile heavy metal, extraction effect and fraction changes of lanthanum (La) and lead (Pb) in the weathering crust elution-deposited rare earth ore were studied by using a compound agent of (NH 4 ) 2 SO 4 -EDTA. The extraction efficiency of La was more than 90% by using 0.2% (NH 4 ) 2 SO 4 -0.005 M EDTA, which was almost same with that by using 2.0% (NH 4 ) 2 SO 4 solution. In contrast, the extraction efficiency of Pb was 62.3% when use 0.2% (NH 4 ) 2 SO 4 -0.005 M EDTA, which is much higher than that (16.16%) achieved by using 2.0% (NH 4 ) 2 SO 4 solution. The released Pb fractions were mainly acid extractable and reducible fractions, and the content of reducible fraction being leached accounted for 70.45% of the total reducible fraction. Therefore, the use of 0.2% (NH 4 ) 2 SO 4 -0.005 M EDTA can not only reduce the amount of (NH 4 ) 2 SO 4 , but also decrease the labile heavy metal residues in soil, which provides a new way for efficient La extraction with effective preventing and controlling environmental pollution in the process of mining the weathering crust elution-deposited rare earth ore. Copyright © 2018 Elsevier Ltd. All rights reserved.

  19. RECOVERY OF PROTACTINIUM

    DOEpatents

    Kraus, K.A.; Moore, G.E.

    1959-02-01

    A process is presented for the separation of protactinium values from an aqueous solution containing Pa and Th values comprising establishing in the solution a HCl concentration of from 4 to 11 molar, contacting the resulting solution with an anion-exchange adsorbent, such as a polystyrene divinyl benzene polymer with quatenary amines as the active exchange group, to effect the adsorption of Pa values upon the adsorbent while leaving Th values in the solution, and then washlng the separated Pa bearing adsorbent with an aqueous solution of HCl of less than 4M to exclusively elute Pa values from the adsorbent. If hexavalent U values are contained in the original solution thcy are adsorbed on the resin together with Pa. A separation is offected chromatographically by percolating the resin with aqueous HCl.

  20. METHOD OF RECOVERING URANIUM COMPOUNDS

    DOEpatents

    Poirier, R.H.

    1957-10-29

    S>The recovery of uranium compounds which have been adsorbed on anion exchange resins is discussed. The uranium and thorium-containing residues from monazite processed by alkali hydroxide are separated from solution, and leached with an alkali metal carbonate solution, whereby the uranium and thorium hydrorides are dissolved. The carbonate solution is then passed over an anion exchange resin causing the uranium to be adsorbed while the thorium remains in solution. The uranium may be recovered by contacting the uranium-holding resin with an aqueous ammonium carbonate solution whereby the uranium values are eluted from the resin and then heating the eluate whereby carbon dioxide and ammonia are given off, the pH value of the solution is lowered, and the uranium is precipitated.

  1. Development of a bi-functional silica monolith for electro-osmotic pumping and DNA clean-up/extraction using gel-supported reagents in a microfluidic device.

    PubMed

    Oakley, Jennifer A; Shaw, Kirsty J; Docker, Peter T; Dyer, Charlotte E; Greenman, John; Greenway, Gillian M; Haswell, Stephen J

    2009-06-07

    A silica monolith used to support both electro-osmotic pumping (EOP) and the extraction/elution of DNA coupled with gel-supported reagents is described. The benefits of the combined EOP extraction/elution system were illustrated by combining DNA extraction and gene amplification using the polymerase chain reaction (PCR) process. All the reagents necessary for both processes were supported within pre-loaded gels that allow the reagents to be stored at 4 degrees C for up to four weeks in the microfluidic device. When carrying out an analysis the crude sample only needed to be hydrodynamically introduced into the device which was connected to an external computer controlled power supply via platinum wire electrodes. DNA was extracted with 65% efficiency after loading lysed cells onto a silica monolith. Ethanol contained within an agarose gel matrix was then used to wash unwanted debris away from the sample by EOP (100 V cm(-1) for 5 min). The retained DNA was subsequently eluted from the monolith by water contained in a second agarose gel, again by EOP using an electric field of 100 V cm(-1) for 5 min, and transferred into the PCR reagent containing gel. The eluted DNA in solution was successfully amplified by PCR, confirming that the concept of a complete self-contained microfluidic device could be realised for DNA sample clean up and amplification, using a simple pumping and on-chip reagent storage methodology.

  2. Method and apparatus for chromatographic quantitative analysis

    DOEpatents

    Fritz, James S.; Gjerde, Douglas T.; Schmuckler, Gabriella

    1981-06-09

    An improved apparatus and method for the quantitative analysis of a solution containing a plurality of anion species by ion exchange chromatography which utilizes a single eluent and a single ion exchange bed which does not require periodic regeneration. The solution containing the anions is added to an anion exchange resin bed which is a low capacity macroreticular polystyrene-divinylbenzene resin containing quarternary ammonium functional groups, and is eluted therefrom with a dilute solution of a low electrical conductance organic acid salt. As each anion species is eluted from the bed, it is quantitatively sensed by conventional detection means such as a conductivity cell.

  3. SEPARATING HAFNIUM FROM ZIRCONIUM

    DOEpatents

    Lister, B.A.J.; Duncan, J.F.; Hutcheon, J.M.

    1956-08-21

    Substantially complete separation of zirconium from hafnium may be obtained by elution of ion exchange material, on which compounds of the elements are adsorbed, with an approximately normal solution of sulfuric acid. Preferably the acid concentration is between 0.8 N amd 1.2 N, amd should not exceed 1.5 N;. Increasing the concentration of sulfate ion in the eluting solution by addition of a soluble sulfate, such as sodium sulfate, has been found to be advantageous. The preferred ion exchange materials are sulfonated polystyrene resins such as Dowex 50,'' and are preferably arranged in a column through which the solutions are passed.

  4. Electrophoretic fractional elution apparatus employing a rotational seal fraction collector

    NASA Technical Reports Server (NTRS)

    Bier, M. (Inventor)

    1977-01-01

    Electrophoretic fractional elution apparatus which has a column with a rotating seal joint is described. A thin jet of eluting buffer is directed across the lumen of the electrophoretic column in a direction perpendicular to that of electrophoretic migration. Either the content of the column is rotated with respect to the stationary jet, or the jet is rotated with respect to the column. The system may employ electrophoresis either in free solution or in packed columns.

  5. [Safety verification for reuse of PET and glass bottles].

    PubMed

    Hayashi, Eiichi; Imai, Toshio; Niimi, Hiroji

    2011-01-01

    In order to verify the safety associated with reusing PET and glass bottles, a challenge test was conducted with five surrogate contaminants: 1,1,1-trichloroethane, chlorobenzene, toluene, benzophenone and phenyl cyclohexane. Bottles were filled with a cocktail solution of these contaminants and stored at 50 °C for 7 days, then washed with water and alkaline solutions. Material and migration tests were conducted at each step. The material test results showed that 430-1,440 µg/g of the contaminants were retained after water washing, and that even after washing with a 3.5% NaOH solution, 225-925 µg/g of the contaminants were retained. The migration tests revealed that 0.095-7.35 µg/mL of the contaminants were eluted. Similar tests were conducted with a soft drink ingredient, limonene. The results revealed that 48 µg/g of limonene was retained even after washing with NaOH solution, and that 0.16 µg/mL of limonene was eluted. Conversely, no contaminants were eluted from glass bottles after washing with the NaOH solution. Thus, from the viewpoint of safety and the preservation of content quality, PET bottles are not considered suitable for reuse when compared with glass bottles.

  6. Recursion equations in predicting band width under gradient elution.

    PubMed

    Liang, Heng; Liu, Ying

    2004-06-18

    The evolution of solute zone under gradient elution is a typical problem of non-linear continuity equation since the local diffusion coefficient and local migration velocity of the mass cells of solute zones are the functions of position and time due to space- and time-variable mobile phase composition. In this paper, based on the mesoscopic approaches (Lagrangian description, the continuity theory and the local equilibrium assumption), the evolution of solute zones in space- and time-dependent fields is described by the iterative addition of local probability density of the mass cells of solute zones. Furthermore, on macroscopic levels, the recursion equations have been proposed to simulate zone migration and spreading in reversed-phase high-performance liquid chromatography (RP-HPLC) through directly relating local retention factor and local diffusion coefficient to local mobile phase concentration. This new approach differs entirely from the traditional theories on plate concept with Eulerian description, since band width recursion equation is actually the accumulation of local diffusion coefficients of solute zones to discrete-time slices. Recursion equations and literature equations were used in dealing with same experimental data in RP-HPLC, and the comparison results show that the recursion equations can accurately predict band width under gradient elution.

  7. Centrifugal precipitation chromatography

    PubMed Central

    Ito, Yoichiro; Lin, Qi

    2009-01-01

    Centrifugal precipitation chromatography separates analytes according their solubility in ammonium sulfate (AS) solution and other precipitants. The separation column is made from a pair of long spiral channels partitioned with a semipermeable membrane. In a typical separation, concentrated ammonium sulfate is eluted through one channel while water is eluted through the other channel in the opposite direction. The countercurrent process forms an exponential AS concentration gradient through the water channel. Consequently, protein samples injected into the water channel is subjected to a steadily increasing AS concentration and at the critical AS concentration they are precipitated and deposited in the channel bed by the centrifugal force. Then the chromatographic separation is started by gradually reducing the AS concentration in the AS channel which lowers the AS gradient concentration in the water channel. This results in dissolution of deposited proteins which are again precipitated at an advanced critical point as they move through the channel. Consequently, proteins repeat precipitation and dissolution through a long channel and finally eluted out from the column in the order of their solubility in the AS solution. The present method has been successfully applied to a number of analytes including human serum proteins, recombinant ketosteroid isomerase, carotenoid cleavage enzymes, plasmid DNA, polysaccharide, polymerized pigments, PEG-protein conjugates, etc. The method is capable to single out the target species of proteins by affinity ligand or immunoaffinity separation. PMID:19541553

  8. PROCESS FOR SEPARATING IODINE-132 FROM FISSION PRODUCTS

    DOEpatents

    Greene, M.W.; Tucker, W.D.; Samos, G.

    1960-06-28

    A process is given for isolating I/sup 132/ in substantially pure form. Te/sup 132/, which is the radioactive parent of I/sup 132/, is adsorbed on a finely divided mass of a chromatographic grade of refractory metal oxide. i.e., alumina, zirconia, titania, and ceria. After a period of time is allowed for the Te/sup 132/ to decay, a 0.001 to 0.01 molar solution of ammonium hydroxide is passed over the finely divided oxides and the I/sup 132/ values are eluted.

  9. Improved method and apparatus for chromatographic quantitative analysis

    DOEpatents

    Fritz, J.S.; Gjerde, D.T.; Schmuckler, G.

    An improved apparatus and method are described for the quantitative analysis of a solution containing a plurality of anion species by ion exchange chromatography which utilizes a single element and a single ion exchange bed which does not require periodic regeneration. The solution containing the anions is added to an anion exchange resin bed which is a low capacity macroreticular polystyrene-divinylbenzene resin containing quarternary ammonium functional groups, and is eluted therefrom with a dilute solution of a low electrical conductance organic acid salt. As each anion species is eluted from the bed, it is quantitatively sensed by conventional detection means such as a conductivity cell.

  10. Efficiency for unretained solutes in packed column supercritical fluid chromatography. I. Theory for isothermal conditions and correction factors for carbon dioxide.

    PubMed

    Poe, Donald P

    2005-06-17

    A general theory for efficiency of nonuniform columns with compressible mobile phase fluids is applied to the elution of an unretained solute in packed-column supercritical fluid chromatography (pSFC). The theoretical apparent plate height under isothermal conditions is given by the Knox equation multiplied by a compressibility correction factor f1, which is equal to the ratio of the temporal-to-spatial average densities of the mobile phase. If isothermal conditions are maintained, large pressure drops in pSFC should not result in excessive efficiency losses for elution of unretained solutes.

  11. Chemical Modification of the Olfactory Receptor Epithelium of Vertebrate Species

    DTIC Science & Technology

    1990-06-28

    Pre-column Derivatization Procedure: 1.0 mL of the Jeffamine solution was mixed with 1.0 mL of NaCN, 5.0 mL of phosphate buffer pH 9.5 followed by 1.0...running buffer. All the unprotonated components elute at the same time because their rate of elution is controlled only by the rate of electroosmotic ...elecarosomotic mobility under our experimental conditions. Using an average elution time of 22.2 min the measured electroosmotic mobility is 1.3 x 10-4 cm2

  12. Investigation of Mercury Reduction in Gold Stripping Process at Elevated Temperature

    NASA Astrophysics Data System (ADS)

    Pramudya, Irawan

    Mercury is present in many gold ores. By processing these ores, there is a potential of emitting mercury to the environment. Carbon regeneration kiln stacks have been observed as one of the primary source of mercury emission into the atmosphere. Before it is recycled back into the carbon in leach (CIL) or carbon in columns (CIC), carbon used in the gold extraction process needs to be reactivated thermally. Emission of mercury can be minimized by keeping the mercury left in the carbon low before it goes to the carbon regeneration kiln stacks. The objective of this study is establishing the optimum elution conditions of mercury cyanide from loaded carbon (which includes the eluent, concentration, temperature and elution time) with respect to gold stripping. Several methods such as acid washing (UNR-100, HCl or ethanol/UNR-100) were investigated prior to the stripping process. Furthermore, conventional pressurized Zadra and modified Zadra were also studied with regards to mercury concentration in the solution and vapor state as well as maximizing the gold stripping from industrial loaded carbon. 7% UNR-100 acid washing of loaded carbon at 80°C was able to wash out approximately 90% of mercury while maintaining the gold adsorption on the carbon (selective washing). The addition of alcohol in the UNR-100 acid washing solution was able to enhance mercury washing from 90% to 97%. Furthermore, mercury stripping using conventional pressurized (cyanide-alkaline) Zadra was best performed at 80°C (minimal amount of mercury reduced and volatilized) whereas using the same process only 40% of gold was stripped, which makes this process not viable. When alcohol was added to the stripping solution, at 80°C, 95% of gold was detected in the solution while keeping the reduction and volatilization of mercury low. The outcome of this study provides a better understanding of mercury behavior during the acid washing and stripping processes so that the risk of mercury exposure and contamination can be minimized while maximizing the gold overall recovery.

  13. Systematic interpolation method predicts protein chromatographic elution with salt gradients, pH gradients and combined salt/pH gradients.

    PubMed

    Creasy, Arch; Barker, Gregory; Carta, Giorgio

    2017-03-01

    A methodology is presented to predict protein elution behavior from an ion exchange column using both individual or combined pH and salt gradients based on high-throughput batch isotherm data. The buffer compositions are first optimized to generate linear pH gradients from pH 5.5 to 7 with defined concentrations of sodium chloride. Next, high-throughput batch isotherm data are collected for a monoclonal antibody on the cation exchange resin POROS XS over a range of protein concentrations, salt concentrations, and solution pH. Finally, a previously developed empirical interpolation (EI) method is extended to describe protein binding as a function of the protein and salt concentration and solution pH without using an explicit isotherm model. The interpolated isotherm data are then used with a lumped kinetic model to predict the protein elution behavior. Experimental results obtained for laboratory scale columns show excellent agreement with the predicted elution curves for both individual or combined pH and salt gradients at protein loads up to 45 mg/mL of column. Numerical studies show that the model predictions are robust as long as the isotherm data cover the range of mobile phase compositions where the protein actually elutes from the column. Copyright © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. LITERATURE REVIEWS TO SUPPORT ION EXCHANGE TECHNOLOGY SELECTION FOR MODULAR SALT PROCESSING

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    King, W

    2007-11-30

    This report summarizes the results of literature reviews conducted to support the selection of a cesium removal technology for application in a small column ion exchange (SCIX) unit supported within a high level waste tank. SCIX is being considered as a technology for the treatment of radioactive salt solutions in order to accelerate closure of waste tanks at the Savannah River Site (SRS) as part of the Modular Salt Processing (MSP) technology development program. Two ion exchange materials, spherical Resorcinol-Formaldehyde (RF) and engineered Crystalline Silicotitanate (CST), are being considered for use within the SCIX unit. Both ion exchange materials havemore » been studied extensively and are known to have high affinities for cesium ions in caustic tank waste supernates. RF is an elutable organic resin and CST is a non-elutable inorganic material. Waste treatment processes developed for the two technologies will differ with regard to solutions processed, secondary waste streams generated, optimum column size, and waste throughput. Pertinent references, anticipated processing sequences for utilization in waste treatment, gaps in the available data, and technical comparisons will be provided for the two ion exchange materials to assist in technology selection for SCIX. The engineered, granular form of CST (UOP IE-911) was the baseline ion exchange material used for the initial development and design of the SRS SCIX process (McCabe, 2005). To date, in-tank SCIX has not been implemented for treatment of radioactive waste solutions at SRS. Since initial development and consideration of SCIX for SRS waste treatment an alternative technology has been developed as part of the River Protection Project Waste Treatment Plant (RPP-WTP) Research and Technology program (Thorson, 2006). Spherical RF resin is the baseline media for cesium removal in the RPP-WTP, which was designed for the treatment of radioactive waste supernates and is currently under construction in Hanford, WA. Application of RF for cesium removal in the Hanford WTP does not involve in-riser columns but does utilize the resin in large scale column configurations in a waste treatment facility. The basic conceptual design for SCIX involves the dissolution of saltcake in SRS Tanks 1-3 to give approximately 6 M sodium solutions and the treatment of these solutions for cesium removal using one or two columns supported within a high level waste tank. Prior to ion exchange treatment, the solutions will be filtered for removal of entrained solids. In addition to Tanks 1-3, solutions in two other tanks (37 and 41) will require treatment for cesium removal in the SCIX unit. The previous SCIX design (McCabe, 2005) utilized CST for cesium removal with downflow supernate processing and included a CST grinder following cesium loading. Grinding of CST was necessary to make the cesium-loaded material suitable for vitrification in the SRS Defense Waste Processing Facility (DWPF). Because RF resin is elutable (and reusable) and processing requires conversion between sodium and hydrogen forms using caustic and acidic solutions more liquid processing steps are involved. The WTP baseline process involves a series of caustic and acidic solutions (downflow processing) with water washes between pH transitions across neutral. In addition, due to resin swelling during conversion from hydrogen to sodium form an upflow caustic regeneration step is required. Presumably, one of these basic processes (or some variation) will be utilized for MSP for the appropriate ion exchange technology selected. CST processing involves two primary waste products: loaded CST and decontaminated salt solution (DSS). RF processing involves three primary waste products: spent RF resin, DSS, and acidic cesium eluate, although the resin is reusable and typically does not require replacement until completion of multiple treatment cycles. CST processing requires grinding of the ion exchange media, handling of solids with high cesium loading, and handling of liquid wash and conditioning solutions. RF processing requires handling and evaporation of cesium eluates, disposal of spent organic resin, and handling of the various liquid wash and regenerate solutions used. In both cases, the DSS will be immobilized in a low activity waste form. It appears that both technologies are mature, well studied, and generally suitable for this application. Technology selection will likely be based on downstream impacts or preferences between the various processing options for the two materials rather than on some unacceptable performance property identified for one material. As a result, the following detailed technical review and summary of the two technologies should be useful to assist in technology selection for SCIX.« less

  15. ADSORPTION METHOD FOR SEPARATING THORIUM VALUES FROM URANIUM VALUES

    DOEpatents

    Boyd, G.E.; Russell, E.R.; Schubert, J.

    1959-08-01

    An improved ion exchange method is described for recovery of uranium and thorium values as separate functions from an aqueous acidic solution containing less than 10/sup -3/ M thorium ions and between 0.1 and 1 M uranyl ions. The solution is passed through a bed of cation exchange resin in the acid form to adsorb all the thorium ions and a portion of the uranyl ions. The uranium is eluted by means of aqueous 0.1 to 0.4 M sulfuric acid. The thorium may then be stripped from the resin by elution with aqueous 0.5 M oxalic acid.

  16. ADSORPTION METHOD FOR SEPARATING THORIUM VALUES FROM URANIUM VALUES

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Boyd, G.E.; Russell, E.R.; Schubert, J.

    An improved ion exchange method is described for recovery of uranium and thorium values as separate functions from an aqueous acidic solution containing less than 10/sup -3/ M thorium ions and between 0.1 and 1 M uranyl ions. The solution is passed through a bed of cation exchange resin in the acid form to adsorb all the thorium ions and a portion of the uranyl ions. The uranium is eluted by means of aqueous 0.1 to 0.4 M sulfuric acid. The thorium may then be stripped from the resin by elution with aqueous 0.5 M oxalic acid.

  17. Application of chitosan and its N-heterocyclic derivatives for preconcentration of noble metal ions and their determination using atomic absorption spectrometry.

    PubMed

    Azarova, Yu A; Pestov, A V; Ustinov, A Yu; Bratskaya, S Yu

    2015-12-10

    Chitosan and its N-heterocyclic derivatives N-2-(2-pyridyl)ethylchitosan (2-PEC), N-2-(4-pyridyl) ethylchitosan (4-PEC), and N-(5-methyl-4-imidazolyl) methylchitosan (IMC) have been applied in group preconcentration of gold, platinum, and palladium for subsequent determination by atomic absorption spectroscopy (AAS) in solutions with high background concentrations of iron and sodium ions. It has been shown that the sorption mechanism, which was elucidated by XPS, significantly influences the sorption capacity of materials, the efficiency of metal ions elution after preconcentration, and, as a result, the accuracy of metal determination by AAS. We have shown that native chitosan was not suitable for preconcentration of Au(III), if the elution step was used as a part of the analysis scheme. The group preconcentration of Au(III), Pd(II), and Pt(IV) with subsequent quantitative elution using 0.1M HCl/1M thiourea solution was possible only on IMC and 4-PEC. Application of IMC for analysis of the national standard quartz ore sample proved that gold could be accurately determined after preconcentration/elution with the recovery above 80%. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. Characterization and antibacterial performance of electrodeposited chitosan-vancomycin composite coatings for prevention of implant-associated infections.

    PubMed

    Ordikhani, F; Tamjid, E; Simchi, A

    2014-08-01

    Orthopaedic implant-associated infections are one of the most serious complications in orthopaedic surgery and a major cause of implant failure. In the present work, drug-eluting coatings based on chitosan containing various amounts of vancomycin were prepared by a cathodic electrophoretic deposition process on titanium foils. A three-step release mechanism of the antibiotic from the films in a phosphate-buffered saline solution was noticed. At the early stage, physical encapsulation of the drug in the hydrogel network controlled the release rate. At the late stage, however, in vitro degradation/deattachment of chitosan was responsible for the controlled release. Cytotoxicity evaluation of the drug-eluting coatings via culturing in human osteosarcoma cells (MG-63 osteoblast-like cell line) showed no adverse effect on the biocompatibility. Antibacterial tests against Gram-positive Staphylococcus aureus also demonstrated that the infection risk of titanium foils was significantly reduced due to the antibiotic release. Additionally, in vitro electrochemical corrosion studies by polarization technique revealed that the corrosion current density was significantly lower for the titanium foils with drug-eluting coatings compared to that of uncoated titanium. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. SEPARATION OF BARIUM VALUES FROM URANYL NITRATE SOLUTIONS

    DOEpatents

    Tompkins, E.R.

    1959-02-24

    The separation of radioactive barium values from a uranyl nitrate solution of neutron-irradiated uranium is described. The 10 to 20% uranyl nitrate solution is passed through a flrst column of a cation exchange resin under conditions favoring the adsorption of barium and certain other cations. The loaded resin is first washed with dilute sulfuric acid to remove a portion of the other cations, and then wash with a citric acid solution at pH of 5 to 7 to recover the barium along with a lesser amount of the other cations. The PH of the resulting eluate is adjusted to about 2.3 to 3.5 and diluted prior to passing through a smaller second column of exchange resin. The loaded resin is first washed with a citric acid solution at a pH of 3 to elute undesired cations and then with citric acid solution at a pH of 6 to eluts the barium, which is substantially free of undesired cations.

  20. Evaluation of a new solid media specimen transport card for high risk HPV detection and cervical cancer prevention.

    PubMed

    Maurer, Kathryn; Luo, Hongxue; Shen, Zhiyong; Wang, Guixiang; Du, Hui; Wang, Chun; Liu, Xiaobo; Wang, Xiamen; Qu, Xinfeng; Wu, Ruifang; Belinson, Jerome

    2016-03-01

    Solid media transport can be used to design adaptable cervical cancer screening programs but currently is limited by one card with published data. To develop and evaluate a solid media transport card for use in high-risk human papillomavirus detection (HR-HPV). The Preventative Oncology International (POI) card was constructed using PK 226 paper(®) treated with cell-lysing solution and indicating dye. Vaginal samples were applied to the POI card and the indicating FTA (iFTA) elute card. A cervical sample was placed in liquid media. All specimens were tested for HR-HPV. Color change was assessed at sample application and at card processing. Stability of the POI card and iFTA elute card was tested at humidity. 319 women were enrolled. Twelve women had at least one insufficient sample with no difference between media (p=0.36). Compared to liquid samples, there was good agreement for HR-HPV detection with kappa of 0.81 (95% CI 0.74-0.88) and 0.71 (95% CI 0.62-0.79) for the POI and iFTA elute card respectively. Sensitivity for ≥CIN2 was 100% (CI 100-100%), 95.1% (CI 92.7-97.6%), and 93.5% (CI 90.7-96.3%) for the HR-HPV test from the liquid media, POI card, and iFTA elute card respectively. There was no color change of the POI card noted in humidity but the iFTA elute card changed color at 90% humidity. The POI card is suitable for DNA transport and HR-HPV testing. This card has the potential to make cervical cancer screening programs more affordable worldwide. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. Size Exclusion Chromatography Studies of the Initial Self-Association Steps of Chicken Egg White Lysozyme Nucleation

    NASA Technical Reports Server (NTRS)

    Ewing, Felecia; Donovan, David; Pusey, Marc

    2000-01-01

    Nucleation is one of the least understood aspects of crystallogenesis. In the case of macromolecule nucleation, this understanding is further hampered by uncertainty over what precisely is being discussed. We define the process of solute self-association (aggregation, oligomerization, interaction, clustering, etc.) whereby n-mers (n > or = 2) having a crystallographic or nascent crystallographic arrangement leading to the critical nucleus reversibly form in the solution, to be part of the nucleation process. This reversible self-association process is a fundamental part of the nucleation process, and occurs as a function of the solute concentration. In the case of chicken egg white lysozyme, a considerable body of experimental evidence leads us to the conclusion that it also forms the crystal growth units. Size exclusion chromatography is a simple and direct method for determining the equilibrium constants for the self-association process. A Pharmacia FPLC system was used to provide accurate solution flow rates. The column, injection valve, and sample loop were all mounted within a temperature-controlled chamber. Chromatographically re-purified lysozyme was first dialyzed against the column equilibration buffer, with injection onto the column after several hours pre-incubation at the running temperature. Preliminary experiments, were carried out using a Toyopearl HW-50F column (1 x 50cm), equilibrated with 0.1 M sodium acetate, 5% sodium chloride, pH 4.6, at 15C. Protein concentrations from 0.1 to 4 mg/ml were employed (C(sub sat) = 1.2 mg/ml). The data from several different protein preparations consistently shows a progressively decreasing elution volume with increasing protein concentration, indicating that reversible self-association is occurring. The dotted line indicates the monomeric lysozyme elution volume. However, lysozyme interacts with the column matrix in these experiments, which complicates data analysis.Accordingly, we are testing silica-based HPLC columns in an effort to eliminate this problem and substantially reduce the column volume and experimental run time. The results and data analysis from these and subsequent experiments will be presented.

  2. Numerical modeling of the elution peak profiles of retained solutes in supercritical fluid chromatography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kaczmarski, Krzysztof; Guiochon, Georges A

    2011-01-01

    In supercritical fluid chromatography (SFC), the significant expansion of the mobile phase along the column causes the formation of axial and radial gradients of temperature. Due to these gradients, the mobile phase density, its viscosity, its velocity, its diffusion coefficients, etc. are not constant throughout the column. This results in a nonuniform flow velocity distribution, itself causing a loss of column efficiency in certain cases, even at low flow rates, as they do in HPLC. At high flow rates, an important deformation of the elution profiles of the sample components may occur. The model previously used to account satisfactorily formore » the retention of an unsorbed solute in SFC is applied to the modeling of the elution peak profiles of retained compounds. The numerical solution of the combined heat and mass balance equations provides the temperature and the pressure profiles inside the column and values of the retention time and the band profiles of retained compounds that are in excellent agreement with independent experimental data for large value of mobile phase reduced density. At low reduced densities, the band profiles can strongly depend on the column axial distribution of porosity.« less

  3. Separation of both fibrous and globular proteins on the basis of molecular weight using high-performance size exclusion chromatography.

    PubMed

    Barden, J A

    1983-11-01

    A high-performance size exclusion liquid chromatographic system has been used to separate proteins with different shapes solely on the basis of their molecular weights. After the effects of ionic and hydrophobic interactions with the stationary phase have been overcome, protein elution is normally governed by their effective size in solution. Conditions are described under which proteins, with isoelectric points within the normal operating pH range of the columns, are eluted independent of their Stokes' radii. Even fibrous proteins with axial ratios of 50 elute according to their known molecular weights over the range 2000-2,000,000.

  4. [Investigation on the process of sapindus saponin purified with macroporous adsorption resin and screening of its bacteriostasis].

    PubMed

    Fu, Yong; Lei, Peng; Han, Yu-mei; Yan, Dan

    2010-02-01

    To study the technological parameters of the purification process of saponins with macroporous adsorption resin. The adsorptive characteristics and elutive parameters of the process were studied by taking the elutive and purified ratio of saponins as markers. Bacteriostasis activity of each parts eluted was evaluated by the mean of cup-plate method. 13.6 mL of the extraction of sapindus saponin (crude drugs 0.01 g/mL) was purified with a column of macroporous adsorption resin (phi15 mm x H90 mm, dry weight 2.5 g) and washed with 3BV of distilled water, then eluted with 3BV of 30% ethanol and 3BV of 70% ethanol, most of saponins were collected in the 70% ethanol. With macroporous adsorption resin adsorbing and purifying, the elutive ratio of saponins was 93.8% and the purity reached 250.1%. So this process of applying macroporous adsorption resin to adsorb and purify saponins is feasible, and supplies reference to the purification of other types of saponin.

  5. Current manufacturing processes of drug-eluting sutures.

    PubMed

    Champeau, Mathilde; Thomassin, Jean-Michel; Tassaing, Thierry; Jérôme, Christine

    2017-11-01

    Drug-eluting sutures represent the next generation of surgical sutures since they fulfill their mechanical functions but also deliver the drug in their vicinity after implantation. These implants are produced by a variety of manufacturing processes. Drug-eluting sutures represent the next generation of surgical sutures since they fulfill their mechanical functions but also deliver the drug in their vicinity after implantation. These implants are produced by a variety of manufacturing processes. Two general approaches can be followed: (i) the ones that add the API into the material during the manufacturing process of the suture and (ii) the ones that load the API to an already manufactured suture. Areas covered: This review provides an overview of the current manufacturing processes for drug-eluting suture production and discusses their benefits and drawbacks depending on the type of drugs. The mechanical properties and the drug delivery profile of drug-eluting sutures are highlighted since these implants must fulfill both criteria. Expert opinion: For limited drug contents, melt extrusion and electrospinning are the emerging processes since the drug is added during the suture manufacture process. Advantageously, the drug release profile can be tuned by controlling the processing parameters specific to each process and the composition of the drug-containing polymer. If high drug content is targeted, the coating or grafting of a drug layer on a pre-manufactured suture allows for preservation of the tensile strength requirements of the suture.

  6. Multiwalled carbon nanotubes as a sorbent material for the solid phase extraction of lead from urine and subsequent determination by electrothermal atomic absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Peña Crecente, Rosa M.; Lovera, Carlha Gutiérrez; García, Julia Barciela; Méndez, Jennifer Álvarez; Martín, Sagrario García; Latorre, Carlos Herrero

    2014-11-01

    The determination of lead in urine is a way of monitoring the chemical exposure to this metal. In the present paper, a new method for the Pb determination by electrothermal atomic absorption spectrometry (ETAAS) in urine at low levels has been developed. Lead was separated from the undesirable urine matrix by means of a solid phase extraction (SPE) procedure. Oxidized multiwalled carbon nanotubes have been used as a sorbent material. Lead from urine was retained at pH 4.0 and was quantitatively eluted using a 0.7 M nitric acid solution and was subsequently measured by ETAAS. The effects of parameters that influence the adsorption-elution process (such as pH, eluent volume and concentration, sampling and elution flow rates) and the atomic spectrometry conditions have been studied by means of different factorial design strategies. Under the optimized conditions, the detection and quantification limits obtained were 0.08 and 0.26 μg Pb L- 1, respectively. The results demonstrate the absence of a urine matrix effect and this is the consequence of the SPE process carried out. Therefore, the developed method is useful for the analysis of Pb at low levels in real samples without the influence of other urine components. The proposed method was applied to the determination of lead in urine samples of unexposed healthy people and satisfactory results were obtained (in the range 3.64-22.9 μg Pb L- 1).

  7. Simple new method for effective concentration of 188Re solutions from alumina-based 188W-188Re generator.

    PubMed

    Guhlke, S; Beets, A L; Oetjen, K; Mirzadeh, S; Biersack, H J; Knapp, F F

    2000-07-01

    (188)Re is a useful generator-produced radioisotope currently under evaluation for a variety of therapeutic applications, including bone pain palliation and intravascular radiation therapy. Because the (188)W parent is available only in a relatively low specific activity (<0.15-0.19 GBq/mg) from reactor irradiation of enriched (186)W, relatively large volumes of 0.9% saline (>15 mL) are required for elution of the (188)Re daughter from traditional alumina-based (188)W-(188)Re generators. Because these large bolus volumes result in solutions with a relatively low specific volume activity of (188)Re (<1 GBq/mL for the 18.5-GBq generator), the availability of effective methods for eluent concentration is important. Our new approach is based on the use of 0.3 mol/L ammonium acetate as a representative salt of a weak acid instead of saline for generator elution. After generator elution, the ammonium acetate generator eluent (15-20 mL) is passed through a tandem IC-H Plus cation (Dowex-H)-anion (QMA Light) column system. Exchange of ammonium cations with hydrogen ions on the cation column forms an acetic acid solution containing perrhenate anions from which the macroscopic levels of the acetate anion of the eluent have been effectively removed. Because perrhenic acid is fully dissociated at this pH, the QMA Light column specifically traps the (188)Re-perrhenate, which is subsequently eluted with a low volume (<1 mL) of saline. Concentration ratios greater than 20:1 are readily achieved with this method. A typical clinical-scale generator loaded with 19.2 GBq (188)W was used to validate the approach. Saline elution provided (188)Re in a 75%-80% yield. Although elution with 0.15 mol/L NH4OAc gave lower yields (55%-60%), use of 0.3 mol/L NH4OAc provided yields comparable with those of saline (70%-75%). (188)W parent breakthrough was not detected after passage of the bolus through the tandem concentration system. Bolus volumes of 15-20 mL, which initially contained as much as 11.1-14.8 GBq (188)Re, were readily concentrated to less than 1 mL saline using QMA Light cartridges. The generator was evaluated for more than 3 mo with no decrease in performance. This approach represents a simple, rapid, and effective method using inexpensive disposable components of concentrating solutions of (188)Re for preparation of therapeutic agents.

  8. Sequential elution process

    DOEpatents

    Kingsley, I.S.

    1987-01-06

    A process and apparatus are disclosed for the separation of complex mixtures of carbonaceous material by sequential elution with successively stronger solvents. In the process, a column containing glass beads is maintained in a fluidized state by a rapidly flowing stream of a weak solvent, and the sample is injected into this flowing stream such that a portion of the sample is dissolved therein and the remainder of the sample is precipitated therein and collected as a uniform deposit on the glass beads. Successively stronger solvents are then passed through the column to sequentially elute less soluble materials. 1 fig.

  9. [Hemapheresis using vesicular plant separation materials].

    PubMed

    Mavrina, L; Ehwald, R; Matthes, G; Stamminger, G

    1990-01-01

    The present paper deals with the separation of cells from soluble compounds of blood by means of exclusion chromatography using a recently described vesicular packing material made from the cell wall framework of the small duckweed Wolffia arrhiza. The cells of the periphere blood are hardly retarded in passing through a packing of the vesicular material and eluted as sharp peak at an elution volume which is near to 30% of the column volume. The behavior of cells is similar to that of the excluded high molecular weight plasma proteins (e.g. serumalbumin). Low molecular weight solutes (e.g. salts, glucose, urea, kreatinin), but also substances of considerable molecular weight (e.g. myoglobin and Vitamin B12) which are usually difficult to separate by dialysis from serum, are eluted at nearly 100% of the packing volume and may be separated completely from cells and high molecular weight proteins. In vitro-Tests did not show a reduced vitality of eluted blood cells.

  10. [Studies on the process of Herba Clinopodii saponins purified with macroporous adsorption resin].

    PubMed

    Zhang, Yi; Yan, Dan; Han, Yumei

    2005-10-01

    To study the technological parameters of the purification process of saponins with macroporous adsorption resin. The adsorptive characteristics and elutive parameters of the process were studied by taking the elutive and purified ratio of saponins as markers. 11.4 ml of the extraction of Herba Clinopodii (crude drugs 0.2 g/ml) was purified with a column of macroporous adsorption resin (phi15 mm x H90 mm, dry weight 2.5 g) and washed with 3BV of distilled water, then eluted with 3BV of 30% ethanol and 3BV of 70% ethanol. Most of saponins were collected in the 70% ethanol. With macroporous adsorption resin adsorbing and purifying,the elutive ratio of saponins is 86.8% and the purity reaches 153.2%. So this process of applying macroporous adsorption resin to adsorb and purify Saponins is feasible.

  11. The detection of Rh antigens (D,C,c,E,e) on bloodstains by a micro-elution technique using low ionic strength solution (LISS) and papain-treated red cells.

    PubMed

    Bargagna, M; Sabelli, M; Giacomelli, C

    1982-01-01

    Ninety experimental bloodstains, were examined, with the intention of detecting the principal Rh antigens, by using a micro-elution method improved by the use of low ionic strength solution (LISS) and papain-treated red cells. This method makes it possible to employ most commercially produced sera in routine forensic haematology laboratory work. The antigens could regularly be detected in stains of the following ages: D, C and c in stains of at least 6 months, E in stains of at least 4 months, and e in stains of at least 2 months.

  12. Indigenous technology development and standardization of the process for obtaining ready to use sterile sodium pertechnetate-Tc-99m solution from Geltech generator

    PubMed Central

    Sarkar, Sishir Kumar; Kothalkar, Chetan; Naskar, Prabhakar; Joshi, Sangeeta; Saraswathy, Padmanabhan; Dey, Arun Chandra; Vispute, Gunvant Leeladhar; Murhekar, Vishwas Vinayak; Pilkhwal, Neelam

    2013-01-01

    Purpose of the Study: The indigenous design and technology development for processing large scale zirconium molybdate-Mo-99 (ZrMo-99) Geltech generator was successfully commissioned in Board of Radiation and Isotope Technology (BRIT), India, in 2006. The generator production facility comprises of four shielded plant facilities equipped with tongs and special process gadgets amenable for remote operations for radiochemical processing of ZrMo-99 gel. Results: Over 2800 Geltech generators have been processed and supplied to user hospitals during the period 2006-2013. Geltech generator supplied by BRIT was initially not sterile. Simple elution of Tc-99m is performed by a sterile evacuated vial with sterile and pyrogen free 0.9% NaCl solution to obtain sodium (Tc-99m) pertechnetate solution. A special type online 0.22 μm membrane filter has been identified and adapted in Geltech generator. Conclusions: The online filtration of Tc-99m from Geltech generator; thus, provided sterile Tc-99m sodium pertechnetate solution. Generators assembled with modified filter assembly were supplied to local hospital in Mumbai Radiation Medicine Centre (RMC) and S.G.S. Medical College and KEM Hospital) and excellent performances were reported by users. PMID:24163509

  13. Interference-free determination of trace copper in freshly ripened honeys by flame atomic absorption spectrometry following a preconcentration by solid-phase extraction and a two-step elution process.

    PubMed

    Pohl, Pawel; Stecka, Helena; Jamroz, Piotr

    2014-02-01

    A fast and straightforward procedure aimed at separating copper (Cu) ions from monosacharides and preconcentrating their traces before flame atomic absorption spectrometry (FAAS) measurements was developed, and its suitability was evaluated by the analysis of freshly ripened honeys on the content of this environmentally and physiologically relevant element. This procedure included the passage (at 20 mL/min) of 10 % (m/v) solutions of honeys (100 mL) through resin beds of Dowex 50 W × 8-400 to retain Cu by solid-phase extraction (SPE) and separate it from the glucose and fructose matrix. In turn, SPE columns were rinsed at 20 mL/min with 20 mL of water and subsequently washed with 20 mL of a 0.5 mol/L HNO3 solution (at 2.0 mL/min) to elute potassium and sodium. Preconcentrated Cu was stripped (at 2.0 mL/min) with 5.0 mL of a 2.0 mol/L HCl solution and determined by FAAS. The proposed procedure was used for the analysis of six ripened monoflower and multiflower honeys, enabling the measurement of Cu within the range of 0.17-0.42 μg/g and with a precision of 3-10%. Recoveries of Cu added to respective honey solutions were within 94-102%, proving the good accuracy of this procedure. The detection limit of Cu achieved with this SPE preconcentration/separation procedure and FAAS detection was 3.6 ng/g.

  14. Generator for ionic gallium-68 based on column chromatography

    DOEpatents

    Neirinckx, Rudi D.; Davis, Michael A.

    1981-01-01

    A physiologically acceptable solution of gallium-68 fluorides, having an activity of 0.1 to 50 millicuries per milliliter of solution is provided. The solution is obtained from a generator comprising germanium-68 hexafluoride bound to a column of an anion exchange resin which forms gallium-68 in situ by eluting the column with an acid solution to form a solution containing .sup.68 Ga-fluorides. The solution then is neutralized prior to administration.

  15. Inhibition of plaque neovascularization and intimal hyperplasia by specific targeting vascular endothelial growth factor with bevacizumab-eluting stent: an experimental study.

    PubMed

    Stefanadis, Christodoulos; Toutouzas, Konstantinos; Stefanadi, Elli; Lazaris, Andreas; Patsouris, Efstratios; Kipshidze, Nicholas

    2007-12-01

    Neovascularization is associated with destabilization of atheromatic plaques. Increased expression of vascular endothelial growth factor (VEGF) is important in the process of neovascularization. We assessed the effect of bevacizumab, a monoclonal antibody specific for VEGF, on neovascularization. We used 12 New Zealand rabbits under atherogenic diet for 3 weeks. We immersed a phosphorycholine coated stent into a solution of 4 ml bevacizumab according to previous studies. Twelve eluting stents and 12 non-eluting stents were implanted in the middle segment of the rabbit's iliac arteries. Follow-up angiography was performed at 4 weeks and tissues were obtained for histological analysis. The procedure of stent loading with bevacizumab and stent implantation was successful. There was no difference in angiographic measurements before, after implantation and at follow-up between the two groups. mean neointimal thickness (0.09+/-0.02 versus 0.12+/-0.02 mm, p<0.01), and mean neointimal area (1.08+/-0.09 versus 1.20+/-0.12 mm(2), p<0.01) were less in the bevacizumab treated segments. bevacizumab-treated arterial segments demonstrated significantly decreased microvessel density compared with the control group (1.69+/-0.06 CI: 1.65-1.73 versus 15.68+/-0.56 CI: 15.32-16.04 vessels per mm(2), p<0.001) and vegf expression was decreased in the media and adventitia of bevacizumab group. Endothelialization, inflammation and injury scores were similar between the two groups. These results suggest that bevacizumab-eluting stent implantation in rabbit iliac arteries is safe, and inhibits neovascularization without affecting the endothelialization.

  16. Simultaneous speciation analysis of chromate, molybdate, tungstate and vanadate in welding fume alkaline extracts by HPLC-ICP-MS.

    PubMed

    Ščančar, Janez; Berlinger, Balázs; Thomassen, Yngvar; Milačič, Radmila

    2015-09-01

    A novel analytical procedure was developed for the simultaneous speciation analysis of chromate, molybdate, tungstate and vanadate by anion-exchange high performance liquid chromatography hyphenated to inductively coupled plasma mass spectrometry (HPLC-ICP-MS). Linear gradient elution from 100% water to 100% 0.7 M NaCl was applied for chromatographic separation of metal species. In standard aqueous solution at neutral pH molybdate, tungstate and vanadate exist in several aqueous species, while chromate is present as a single CrO4(2-) species. Consequently, only chromate can be separated from this solution in a sharp chromatographic peak. For obtaining sharp chromatographic peaks for molybdate, tungstate and vanadate, the pH of aqueous standard solutions was raised to 12. At highly alkaline conditions single CrO4(2-), MoO4(2-) and WO4(2-) are present and were eluted in sharp chromatographic peaks, while VO4(3-) species, which predominates at pH 12 was eluted in slightly broaden peak. In a mixture of aqueous standard solutions (pH 12) chromate, molybdate, tungstate and vanadate were eluted at retention times from 380 to 420 s, 320 to 370 s, 300 to 350 s and 240 to 360 s, respectively. Eluted species were simultaneously detected on-line by ICP-MS recording m/z 52, 95, 182 and 51. The developed procedure was successfully applied to the analysis of leachable concentrations of chromate, molybdate, tungstate and vanadate in alkaline extracts (2% NaOH+3% Na2CO3) of manual metal arc (MMA) welding fumes loaded on filters. Good repeatability and reproducibility of measurement (RSD±3.0%) for the investigated species were obtained in both aqueous standard solutions (pH 12) and in alkaline extracts of welding fumes. Low limits of detection (LODs) were found for chromate (0.02 ng Cr mL(-1)), molybdate (0.1 ng Mo mL(-1)), tungstate (0.1 ng W mL(-1)) and vanadate (0.2 ng V mL(-1)). The accuracy of analytical procedure for the determination of chromate was checked by analysis of CRM 545, Cr(VI) in welding dust loaded on a filter. Good agreement between determined and reported certified values was obtained. For molybdate, tungstate and vanadate the assessment of accuracy was performed by spiking welding fume filters. Good recoveries for all investigated species (98-101%) confirmed the accuracy of the analytical procedure. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. a bare Nanocapillary for DNA Separation and Genotyping analysis in Gel-Free solutions without application of external electric field

    PubMed Central

    Wang, Xiayan; Wang, Shili; Veerappan, Vijaykumar; Byun, Chang Kyu; Nguyen, Han; Gendhar, Brina; Allen, Randy D.; Liu, Shaorong

    2009-01-01

    In this work, we demonstrate DNA separation and genotyping analysis in gel-free solutions using a nanocapillary under pressure-driven conditions without application of an external electric field. The nanocapillary is a ~50-cm-long and 500-nm-radius bare fused silica capillary. After a DNA sample is injected, the analytes are eluted out in a chromatographic separation format. The elution order of DNA molecules follows strictly with their sizes, with the longer DNA being eluted out faster than the shorter ones. High resolutions are obtained for both short (a few bases) and long (tens of thousands of base pairs) DNA fragments. Effects of key experimental parameters, such as eluent composition and elution pressure, on separation efficiency and resolution are investigated. We also apply this technique for DNA separations of real-world genotyping samples to demonstrate its feasibility in biological applications. PCR products (without any purification) amplified from Arabidopsis plant genomic DNA crude preparations are directly injected into the nanocapillary, and PCR-amplified DNA fragments are well resolved, allowing for unambiguous identification of samples from heterozygous and homozygous individuals. Since the capillaries used to conduct the separations are uncoated, column lifetime is virtually unlimited. The only material that is consumed in these assays is the eluent, and hence the operation cost is low. PMID:18500828

  18. Characterization of long-term elution of platinum from carboplatin-impregnated calcium sulfate hemihydrate beads in vitro by two distinct sample collection methods.

    PubMed

    Tulipan, Rachel J; Phillips, Heidi; Garrett, Laura D; Dirikolu, Levent; Mitchell, Mark A

    2017-05-01

    OBJECTIVE To characterize long-term elution of platinum from carboplatin-impregnated calcium sulfate hemihydrate (CI-CSH) beads in vitro by comparing 2 distinct sample collection methods designed to mimic 2 in vivo environments. SAMPLES 162 CI-CSH beads containing 4.6 mg of carboplatin (2.4 mg of platinum/bead). PROCEDURES For method 1, which mimicked an in vivo environment with rapid and complete fluid exchange, each of 3 plastic 10-mL conical tubes contained 3 CI-CSH beads and 5 mL of PBS solution. Eluent samples were obtained by evacuation of all fluid at 1, 2, 3, 6, 9, and 12 hours and 1, 2, 3, 6, 9, 12, 15, 18, 22, 26, and 30 days. Five milliliters of fresh PBS solution was then added to each tube. For method 2, which mimicked an in vivo environment with no fluid exchange, each of 51 tubes (ie, 3 tubes/17 sample collection times) contained 3 CI-CSH beads and 5 mL of PBS solution. Eluent samples were obtained from the assigned tubes for each time point. All samples were analyzed for platinum content by inductively coupled plasma-mass spectrometry. RESULTS Platinum was released from CI-CSH beads for 22 to 30 days. Significant differences were found in platinum concentration and percentage of platinum eluted from CI-CSH beads over time for each method. Platinum concentrations and elution percentages in method 2 samples were significantly higher than those of method 1 samples, except for the first hour measurements. CONCLUSIONS AND CLINICAL RELEVANCE Sample collection methods 1 and 2 may provide estimates of the minimum and maximum platinum release, respectively, from CI-CSH beads in vivo.

  19. Influence of septic system wastewater treatment on titanium dioxide nanoparticle subsurface transport mechanisms.

    PubMed

    Waller, Travis; Marcus, Ian M; Walker, Sharon L

    2018-06-04

    Engineered nanomaterials (ENMs) are commonly incorporated into food and consumer applications to enhance a specific product aspect (i.e., optical properties). Life cycle analyses revealed ENMs can be released from products during usage and reach wastewater treatment plants (WWTPs), with titanium dioxide (TiO 2 ) accounting for a large fraction. As such, food grade (FG) TiO 2 , a more common form of TiO 2 in wastewater, was used in this study. Nanomaterials in WWTPs have been well characterized, although the problematic septic system has been neglected. Elution and bioaccumulation of TiO 2 ENMs from WTTPs in downriver sediments and microorganisms has been observed; however, little is known about mechanisms governing the elution of FG TiO 2 from the septic drainage system. This study characterized the transport behavior and mechanisms of FG TiO 2 particles in porous media conditions after septic waste treatment. FG and industrial grade (IG) TiO 2 (more commonly studied) were introduced to septic tank effluent and low-ionic strength electrolyte solutions prior to column transport experiments. Results indicate that FG TiO 2 aggregate size (200-400 nm) remained consistent across solutions. Additionally, elution of FG and IG TiO 2 was greatest in septic effluent at the higher nanoparticle concentration (100 ppm). FG TiO 2 was well retained at the low (2 ppm) concentration in septic effluent, suggesting that particles that escape the septic system may still be retained in drainage field before reaching the groundwater system, although eluted particles are highly stabilized. Findings provide valuable insight into the significance of the solution environment at mediating differences observed between uniquely engineered nanomaterials. Graphical abstract.

  20. Stent Coating Integrity of Durable and Biodegradable Coated Drug Eluting Stents.

    PubMed

    Yazdani, Saami K; Sheehy, Alexander; Pacetti, Stephen; Rittlemeyer, Brandon; Kolodgie, Frank D; Virmani, Renu

    2016-10-01

    Coatings consisting of a polymer and drug are widely used in drug-eluting stents (DES) and are essential in providing programmable drug release kinetics. Among other factors, stent coating technologies can influence blood compatibility, affect acute and sub-acute healing, and potentially trigger a chronic inflammatory response. The aim of this study was to investigate the short-term (7 and 28 days) and long-term (90 and 180 days) coating integrity of the Xience Prime Everolimus-Eluting Stent (EES), Resolute Zotarolimus-Eluting Stent (ZES), Taxus Paclitaxel-Eluting Stent (PES), and Nobori Biolimus A9-Eluting Stent (BES) in a rabbit ilio-femoral stent model. Stented arteries (n = 48) were harvested and the tissue surrounding the implanted stents digested away with an enzymatic solution. Results demonstrated that the majority of struts of EES were without any coating defects with a few struts showing minor defects. Similarly, for the ZES, most of the struts were without coating defects at all time points except at 180 days. The majority of PES demonstrated mostly webbing and uneven coating. In the BES group, the majority of strut coating showed polymer cracking. Overall, the EES and ZES had fewer coating defects than the PES and BES. Coating defects, however increase over time for the ZES, whereas the percent of coating irregularities remained constant for the EES. These results provide, for the first time, a comparison of the long-term durability of these drug-eluting stent coatings in vivo. © 2016, Wiley Periodicals, Inc.

  1. Buoyancy-induced mixing during wash and elution steps in expanded bed adsorption.

    PubMed

    Fee, C J; Liten, A D

    2001-01-01

    Buoyancy-induced mixing occurs during expanded bed adsorption processes when the feed stream entering the bottom of the system has a lower density than that of the fluid above it. In the absence of a headspace, mixing in the expanded bed can be modeled as a single, well-mixed vessel, with first-order dynamics. In the presence of a headspace, the system exhibits second-order dynamics for the densities typically encountered in protein chromatography, and can be modeled as two well-mixed vessels (the expanded bed and the headspace) arranged in series. In this paper, the mixing dynamics of the expanded bed are described and a mathematical model of the system is presented. Experimental measurements of density changes during the dilution of sucrose and salt solutions in a STREAMLINE 25 column are presented. These show excellent agreement with predictions using the model. A number of strategies for wash and elution in expanded mode, both in the presence and absence of headspace, are discussed.

  2. ELUTION OF ORGANIC SOLUTES FROM DIFFERENT POLARITY SORBENTS USING SUBCRITICAL WATER. (R825394)

    EPA Science Inventory

    The intermolecular interactions between organic solutes and sorbent matrices under subcritical water conditions have been investigated at a pressure of 50 bar and temperatures ranging from 50 to 250°C. Both polar and nonpolar organics (chlorophenols, amines, n-alkanes...

  3. An easy-to-use calculating machine to simulate steady state and non-steady-state preparative separations by multiple dual mode counter-current chromatography with semi-continuous loading of feed mixtures.

    PubMed

    Kostanyan, Artak E; Shishilov, Oleg N

    2018-06-01

    Multiple dual mode counter-current chromatography (MDM CCC) separation processes with semi-continuous large sample loading consist of a succession of two counter-current steps: with "x" phase (first step) and "y" phase (second step) flow periods. A feed mixture dissolved in the "x" phase is continuously loaded into a CCC machine at the beginning of the first step of each cycle over a constant time with the volumetric rate equal to the flow rate of the pure "x" phase. An easy-to-use calculating machine is developed to simulate the chromatograms and the amounts of solutes eluted with the phases at each cycle for steady-state (the duration of the flow periods of the phases is kept constant for all the cycles) and non-steady-state (with variable duration of alternating phase elution steps) separations. Using the calculating machine, the separation of mixtures containing up to five components can be simulated and designed. Examples of the application of the calculating machine for the simulation of MDM CCC processes are discussed. Copyright © 2018 Elsevier B.V. All rights reserved.

  4. Liquid chromatographic extraction medium

    DOEpatents

    Horwitz, E. Philip; Dietz, Mark L.

    1994-01-01

    A method and apparatus for extracting strontium and technetium values from biological, industrial and environmental sample solutions using a chromatographic column is described. An extractant medium for the column is prepared by generating a solution of a diluent containing a Crown ether and dispersing the solution on a resin substrate material. The sample solution is highly acidic and is introduced directed to the chromatographic column and strontium or technetium is eluted using deionized water.

  5. An improved filter elution and cell culture assay procedure for evaluating public groundwater systems for culturable enteroviruses.

    PubMed

    Dahling, Daniel R

    2002-01-01

    Large-scale virus studies of groundwater systems require practical and sensitive procedures for both sample processing and viral assay. Filter adsorption-elution procedures have traditionally been used to process large-volume water samples for viruses. In this study, five filter elution procedures using cartridge filters were evaluated for their effectiveness in processing samples. Of the five procedures tested, the third method, which incorporated two separate beef extract elutions (one being an overnight filter immersion in beef extract), recovered 95% of seeded poliovirus compared with recoveries of 36 to 70% for the other methods. For viral enumeration, an expanded roller bottle quantal assay was evaluated using seeded poliovirus. This cytopathic-based method was considerably more sensitive than the standard plaque assay method. The roller bottle system was more economical than the plaque assay for the evaluation of comparable samples. Using roller bottles required less time and manipulation than the plaque procedure and greatly facilitated the examination of large numbers of samples. The combination of the improved filter elution procedure and the roller bottle assay for viral analysis makes large-scale virus studies of groundwater systems practical. This procedure was subsequently field tested during a groundwater study in which large-volume samples (exceeding 800 L) were processed through the filters.

  6. DNA adsorption to and elution from silica surfaces: influence of amino acid buffers.

    PubMed

    Vandeventer, Peter E; Mejia, Jorge; Nadim, Ali; Johal, Malkiat S; Niemz, Angelika

    2013-09-19

    Solid phase extraction and purification of DNA from complex samples typically requires chaotropic salts that can inhibit downstream polymerase amplification if carried into the elution buffer. Amino acid buffers may serve as a more compatible alternative for modulating the interaction between DNA and silica surfaces. We characterized DNA binding to silica surfaces, facilitated by representative amino acid buffers, and the subsequent elution of DNA from the silica surfaces. Through bulk depletion experiments, we found that more DNA adsorbs to silica particles out of positively compared to negatively charged amino acid buffers. Additionally, the type of the silica surface greatly influences the amount of DNA adsorbed and the final elution yield. Quartz crystal microbalance experiments with dissipation monitoring (QCM-D) revealed multiphasic DNA adsorption out of stronger adsorbing conditions such as arginine, glycine, and glutamine, with DNA more rigidly bound during the early stages of the adsorption process. The DNA film adsorbed out of glutamate was more flexible and uniform throughout the adsorption process. QCM-D characterization of DNA elution from the silica surface indicates an uptake in water mass during the initial stage of DNA elution for the stronger adsorbing conditions, which suggests that for these conditions the DNA film is partly dehydrated during the prior adsorption process. Overall, several positively charged and polar neutral amino acid buffers show promise as an alternative to methods based on chaotropic salts for solid phase DNA extraction.

  7. Integrated microwave processing system for the extraction of organophosphorus pesticides in fresh vegetables.

    PubMed

    Wu, Lijie; Song, Ying; Hu, Mingzhu; Xu, Xu; Zhang, Hanqi; Yu, Aimin; Ma, Qiang; Wang, Ziming

    2015-03-01

    A simple and efficient integrated microwave processing system (IMPS) was firstly assembled and validated for the extraction of organophosphorus pesticides in fresh vegetables. Two processes under microwave irradiation, dynamic microwave-assisted extraction (DMAE) and microwave-accelerated solvent elution (MASE), were integrated for simplifying the pretreatment of the sample. Extraction, separation, enrichment and elution were finished in a simple step. The organophosphorus pesticides were extracted from the fresh vegetables into hexane with DMAE, and then the extract was directly introduced into the enrichment column packed with active carbon fiber (ACF). Subsequently, the organophosphorus pesticides trapped on the ACF were eluted with ethyl acetate under microwave irradiation. No further filtration or cleanup was required before analysis of the eluate by gas chromatography-mass spectrometry. Some experimental parameters affecting extraction efficiency were investigated and optimized, such as microwave output power, kind and volume of extraction solvent, extraction time, amount of sorbent, elution microwave power, kind and volume of elution solvent, elution solvent flow rate. Under the optimized conditions, the recoveries were in the range of 71.5-105.2%, and the relative standard deviations were lower than 11.6%. The experiment results prove that the present method is a simple and effective sample preparation method for the determination of pesticides in solid samples. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. Solid-phase extraction sorbent consisting of alkyltrimethylammonium surfactants immobilized onto strong cation-exchange polystyrene resin.

    PubMed

    Reid, Kendra R; Kennedy, Lonnie J; Crick, Eric W; Conte, Eric D

    2002-10-25

    Presented is a solid-phase extraction sorbent material composed of cationic alkyltrimethylammonium surfactants attached to a strong cation-exchange resin via ion-exchange. The original hydrophilic cation-exchange resin is made hydrophobic by covering the surface with alkyl chains from the hydrophobic portion of the surfactant. The sorbent material now has a better ability to extract hydrophobic molecules from aqueous samples. The entire stationary phase (alkyltrimethylammonium surfactant) is removed along with the analyte during the elution step. The elution step requires a mild elution solvent consisting of 0.25 M Mg2+ in a 50% 2-propanol solution. The main advantage of using a removable stationary phase is that traditionally utilized toxic elution solvents such as methylene chloride, which are necessary to efficiently release strongly hydrophobic species from SPE stationary phases, may now be avoided. Also, the final extract is directly compatible with reversed-phase liquid chromatography. The performance of this procedure is presented using pyrene as a test molecule.

  9. Separation of protactinum, actinium, and other radionuclides from proton irradiated thorium target

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fassbender, Michael E.; Radchenko, Valery

    Protactinium, actinium, radium, radiolanthanides and other radionuclide fission products were separated and recovered from a proton-irradiated thorium target. The target was dissolved in concentrated HCl, which formed anionic complexes of protactinium but not with thorium, actinium, radium, or radiolanthanides. Protactinium was separated from soluble thorium by loading a concentrated HCl solution of the target onto a column of strongly basic anion exchanger resin and eluting with concentrated HCl. Actinium, radium and radiolanthanides elute with thorium. The protactinium that is retained on the column, along with other radionuclides, is eluted may subsequently treated to remove radionuclide impurities to afford a fractionmore » of substantially pure protactinium. The eluate with the soluble thorium, actinium, radium and radiolanthanides may be subjected to treatment with citric acid to form anionic thorium, loaded onto a cationic exchanger resin, and eluted. Actinium, radium and radiolanthanides that are retained can be subjected to extraction chromatography to separate the actinium from the radium and from the radio lanthanides.« less

  10. [Purification Technology Optimization for Saponins from Ziziphi Spinosae Semen with Macroporous Adsorption Resin by Box-Behnken Design-Response Surface Methodology].

    PubMed

    Zhao, Hui-ru; Ren, Zao; Liu, Chun-ye

    2015-04-01

    To compare the purification effect of saponins from Ziziphi Spinosae Semen with different types of macroporous adsorption resin, and to optimize its purification technology. The type of macroporous resins was optimized by static adsorption method. The optimum technological conditions of saponins from Ziziphi Spinosae Semen was screened by single factor test and Box-Behnken Design-Response Surface Methodology. AB-8 macroporous resin had better purification effect of total saponins than other resins, optimum technological parameters were as follows: column height-diameter ratio was 5: 1, the concentration of sample solution was 2. 52 mg/mL, resin adsorption quantity was 8. 915 mg/g, eluted by 3 BV water, flow rate of adsorption and elution was 2 BV/h, elution solvent was 75% ethanol, elution solvent volume was 5 BV. AB-8 macroporous resin has a good purification effect on jujuboside A. The optimized technology is stable and feasible.

  11. Method for liquid chromatographic extraction of strontium from acid solutions

    DOEpatents

    Horwitz, E. Philip; Dietz, Mark L.

    1992-01-01

    A method and apparatus for extracting strontium and technetium values from biological, industrial and environmental sample solutions using a chromatographic column is described. An extractant medium for the column is prepared by generating a solution of a diluent containing a Crown ether and dispersing the solution on a resin substrate material. The sample solution is highly acidic and is introduced directed to the chromatographic column and strontium or technetium is eluted using deionized water.

  12. Liquid chromatographic extraction medium

    DOEpatents

    Horwitz, E.P.; Dietz, M.L.

    1994-09-13

    A method and apparatus are disclosed for extracting strontium and technetium values from biological, industrial and environmental sample solutions using a chromatographic column. An extractant medium for the column is prepared by generating a solution of a diluent containing a Crown ether and dispersing the solution on a resin substrate material. The sample solution is highly acidic and is introduced directed to the chromatographic column and strontium or technetium is eluted using deionized water. 1 fig.

  13. The Resin-in-pulp Process and Its Application to Ores from Brosses "BRS 10"; LE PROCEDE "RESIN IN PULP" ET SON APPLICATION AUX MINERAIS DES BROSSES "BRS 10"

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kremer, M.

    1959-03-01

    The resin-in-pulp process is a technical variant of the recovery process of uranium in dilute solution by means of ion exchange resins. An anion resin, XE 123, of a welldefined grain size is placed in direct contact with the pulp produced by sulfuric acid attack on ore with a low uranium content. This process is of particular value in the treatment of pulps that cannot be filtered or decanted, such as those obtained with ore from Brosses. The preparation of the pulp, the elution of the uranium, and its fixation, as well as the various factors encountered in these operations,more » are discussed. (auth)« less

  14. In Situ Analysis of Organics with a Portable Mass Spectrometer

    NASA Technical Reports Server (NTRS)

    Soparawalla, Santosh

    2011-01-01

    The search for extra-terrestrial life starts at home. In order to find life on other planets, we start by examining life processes we understand on the earth. Though it may not be possible to see the life in the form of macroscopic organisms, telltale signs of life can exist in the form of small organic molecules such as peptides and amino acids. Our overall goal is to test a portable mass spectrometer (MS) system, the Mini 10.5, for astrobiological applications including in situ hydrocarbon analysis and sediments analysis using an additional automated sample processing system (ASPS). The collaborative research focuses on two current projects in the field of astrobiology. Both projects are geared towards examining organics distributed in extreme environments. One portion of study attempts to qualitatively analyze the effect of volatile organic compounds (VOC) produced by diesel exhaust on lichens growing in the desert. This requires measurements to be taken by bringing the instrument to the Mojave Desert and monitoring atmospheric composition of VOCs in situ. The second project is to evaluate the miniature MS system as a detector for the ASPS extraction system. A major obstacle of any chemometric in situ analysis is the suppression of analyte signal by concomitant signal from the surrounding environment. The ASPS extraction device has been developed at JPL to extract amino acids from sediment samples and elute them in solution. The solution is eluted at a high pH and needs to be conditioned to a more neutral pH so that dissolved amino acids can be readily protonated and subsequently analyzed by electrospray MS.

  15. DNA Adsorption to and Elution from Silica Surfaces: Influence of Amino Acid Buffers

    PubMed Central

    Vandeventer, Peter E.; Mejia, Jorge; Nadim, Ali; Johal, Malkiat S.; Niemz, Angelika

    2014-01-01

    Solid phase extraction and purification of DNA from complex samples typically requires chaotropic salts that can inhibit downstream polymerase amplification if carried into the elution buffer. Amino acid buffers may serve as a more compatible alternative for modulating the interaction between DNA and silica surfaces. We characterized DNA binding to silica surfaces, facilitated by representative amino acid buffers, and the subsequent elution of DNA from the silica surfaces. Through bulk depletion experiments, we found that more DNA adsorbs to silica particles out of positively compared to negatively charged amino acid buffers. Additionally, the type of the silica surface greatly influences the amount of DNA adsorbed, and the final elution yield. Quartz crystal microbalance experiments with dissipation monitoring (QCM-D) revealed multiphasic DNA adsorption out of stronger adsorbing conditions such as arginine, glycine, and glutamine, with DNA more rigidly bound during the early stages of the adsorption process. The DNA film adsorbed out of glutamate was more flexible and uniform throughout the adsorption process. QCM-D characterization of DNA elution from the silica surface indicates an uptake in water mass during the initial stage of DNA elution for the stronger adsorbing conditions, which suggests that for these conditions the DNA film is partly dehydrated during the prior adsorption process. Overall, several positively charged and polar neutral amino acid buffers show promise as an alternative to methods based on chaotropic salts for solid phase DNA extraction. PMID:23931415

  16. Overloaded elution band profiles of ionizable compounds in reversed-phase liquid chromatography: Influence of the competition between the neutral and the ionic species

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gritti, Fabrice; Guiochon, Georges A

    2008-01-01

    The parameters that affect the shape of the band profiles of acido-basic compounds under moderately overloaded conditions (sample size less than 500 nmol for a conventional column) in RPLC are discussed. Only analytes that have a single pK{sub a} are considered. In the buffer mobile phase used for their elution, their dissociation may, under certain conditions, cause a significant pH perturbation during the passage of the band. Two consecutive injections (3.3 and 10 {micro}L) of each one of three sample solutions (0.5, 5, and 50 mM) of ten compounds were injected on five C{sub 18}-bonded packing materials, including the 5more » {micro}m Xterra-C{sub 18} (121 {angstrom}), 5 {micro}m Gemini-C{sub 18} (110 {angstrom}), 5 {micro}m Luna-C{sub 18}(2) (93 {angstrom}), 3.5 {micro}m Extend-C{sub 18} (80 {angstrom}), and 2.7 {micro}m Halo-C{sub 18} (90 {angstrom}). The mobile phase was an aqueous solution of methanol buffered at a constant {sub W}{sup W}pH of 6, with a phosphate buffer. The total concentration of the phosphate groups was constant at 50 mM. The methanol concentration was adjusted to keep all the retention factors between 1 and 10. The compounds injected were phenol, caffeine, 3-phenyl 1-propanol, 2-phenyl butyric acid, amphetamine, aniline, benzylamine, p-toluidine, procainamidium chloride, and propranololium chloride. Depending on the relative values of the analyte pK{sub a} and the buffer solution pH, these analytes elute as the neutral, the cationic, or the anionic species. The influence of structural parameters such as the charge, the size, and the hydrophobicity of the analytes on the shape of its overloaded band profile is discussed. Simple but general rules predict these shapes. An original adsorption model is proposed that accounts for the unusual peak shapes observed when the analyte is partially dissociated in the buffer solution during its elution.« less

  17. Sorption of uranium in uranyl nitrate solutions on strong cationic resins and its elution with ammonium sulfate. II. Effects of EDTA on thorium decontamination; Estudos de sorpcao de uranio contido em solucoes de nitrato de uranilo por resina cationica forte e sua eluicao com sulfato de amonio. Parte II: efeito de EDTA na descontaminacao do torio (in Portuguese)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ribas, Antonio G.S.; Abrao, Alcidio

    1970-05-15

    This paper describes the studies of decontamination of thorium present as impurity in uranyl nitrate solutions, which was carried out through strong cationic resin where the thorium was partially retained. Then, the final decontamination was performed percolating the uranyl solution on a second cationic resin, after complexation of thorium (and other impurities) with EDTA. The thorium decontamination and the uranium retention were studied as a function of EDTA/U ratio, uranium concentration and acidity of the influent uranyl nitrate. The elution conditions were also studied as a function of eluent flow rate, concentration and acidity. Several tables and graphs showing themore » final results are included. (tr-auth)« less

  18. Enhanced performance of magnesium alloy for drug-eluting vascular scaffold application

    NASA Astrophysics Data System (ADS)

    Dong, Hongzhou; Li, Daikun; Mao, Daoyong; Bai, Ningning; Chen, Yashi; Li, Qing

    2018-03-01

    Bio-absorbable magnesium alloys drug-eluting vascular scaffold was developed to resolve the defect of permanent metal and drug-eluting stents, most notably a chronic vessel wall inflammation and the risk of stent thrombosis. Nevertheless, violent chemical reaction and rapid degradation under physiological conditions limits their application. Furthermore, multifunctional drug-eluting stents which could reduce the formation of thrombus and repair the damaged vessels need more attention to fundamentally cure the coronary artery disease. Herein, a drug delivery system (Mg/MgO/PLA-FA) which can realize sustainable release of ferulaic acid was designed via anodic oxidation process and dip coating process. Electrochemical tests and immersion experiments showed that the superior anticorrosion behavior, it is due to the dense MgO-PLA composite layer. The released ferulaic acid can effectively decrease platelets adhesion and aggregation during the early stage of implantation. Besides, hemolysis tests showed that the composite coatings endowed the Mg alloy with a low hemolysis ratio. The Mg/MgO/PLA-FA composite materials may be appropriate for applications on biodegradable Mg alloys drug-eluting stents.

  19. Ultra preconcentration of polycyclic aromatic hydrocarbons in smoked bacon by a combination of SPE and DLLME.

    PubMed

    Liu, Xiaofang; Zhou, Shu; Zhu, Quanfei; Ye, Yong; Chen, Huaixia

    2014-09-01

    A sample pretreatment method, solid-phase extraction combined with dispersive liquid-liquid microextraction (SPE-DLLME), was established for the sensitive determination of polycyclic aromatic hydrocarbons (PAHs) in smoked bacon samples. In the SPE-DLLME process, three PAHs including naphthalene (Naph), phenanthrene (Phen) and pyrene (Pyr) were extracted from samples and transferred into C18 SPE cartridge. The target analytes were subsequently eluted with 1.2 ml of acetonitrile-dichloromethane (5:1, v/v) mixture solution. The eluent was injected directly into the 5.0 ml ultrapure water in the subsequent DLLME procedure. The sedimented phase was concentrated under a gentle nitrogen flow to 120.0 µl. Finally, the analytes in the extraction solvent were determined by high-performance liquid chromatography with a ultra-violet detector. Some important extraction parameters affecting the performance, such as the sample solution flow rate, breakthrough volume, salt addition as well as the type and volume of the elution solvent were optimized. The developed method provided an ultra enrichment factors for PAHs ranged from 3478 to 3824. The method was applied for the selective extraction and sensitive determination of PAHs in smoked bacon samples. The limits of detection (S/N = 3) were 0.05, 0.01, 0.02 μg kg(-1) for Naph, Phen, Pyr, respectively. © The Author [2013]. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  20. Fast Gradient Elution Reversed-Phase HPLC with Diode-Array Detection as a High Throughput Screening Method for Drugs of Abuse

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Peter W. Carr; K.M. Fuller; D.R. Stoll

    A new approach has been developed by modifying a conventional gradient elution liquid chromatograph for the high throughput screening of biological samples to detect the presence of regulated intoxicants. The goal of this work was to improve the speed of a gradient elution screening method over current approaches by optimizing the operational parameters of both the column and the instrument without compromising the reproducibility of the retention times, which are the basis for the identification. Most importantly, the novel instrument configuration substantially reduces the time needed to re-equilibrate the column between gradient runs, thereby reducing the total time for eachmore » analysis. The total analysis time for each gradient elution run is only 2.8 minutes, including 0.3 minutes for column reequilibration between analyses. Retention times standard calibration solutes are reproducible to better than 0.002 minutes in consecutive runs. A corrected retention index was adopted to account for day-to-day and column-to-column variations in retention time. The discriminating power and mean list length were calculated for a library of 47 intoxicants and compared with previous work from other laboratories to evaluate fast gradient elution HPLC as a screening tool.« less

  1. An optimized method for elution of enteroviral RNA from a cellulose-based substrate.

    PubMed

    Li, Yan; Yoshida, Hiromu; Wang, Lu; Tao, Zexin; Wang, Haiyan; Lin, Xiaojuan; Xu, Aiqiang

    2012-12-01

    The Flinders Technology Australia (FTA) Elute Card is a commercial product that facilitates the collection, transport, archiving and processing of nucleic acids from a wide variety of biological samples at room temperature. While the cards have been designed so that sterile/deionized water can elute DNA easily, they are not suitable for some less stable RNAs. This study was undertaken to determine the optimal conditions such as the buffer type, buffer pH and incubation temperature for the elution of enteroviral RNA from FTA Elute Cards prior to quantitative analysis using real-time PCR (qPCR) or consensus degenerate hybrid oligonucleotide primer VP1 RT-semi nested PCR (CODEHOP VP1 RT-snPCR). TE-1 (pH 8.0), rather than sterile water, was the best buffer for high efficiency elution of enteroviral RNA at 95°C. However, as the estimated recovery rate of viral RNA eluted from the cards averaged to be only 6.1%, enterovirus assays using FTA elution should be considered qualitative, especially at low virus titers, and therefore the results of the assay should be interpreted carefully. Copyright © 2012 Elsevier B.V. All rights reserved.

  2. Forced-flow chromatographic determination of calcium and magnesium with continuous spectrophotometric detection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Arguello, M.D.

    1977-12-01

    Modifications to the forced-flow chromatograph include a flow-through pH monitor to continuously monitor the pH of the final effluent and an active low-pass filter to eliminate noise in the spectrophotometric detector. All separations are performed using partially sulfonated XAD-2 as the ion exchanger. Elution of calcium and magnesium is accomplished using ammonium chloride and ethylenediammonium chloride solutions. Calcium and magnesium are detected by means of Arsenazo I and PAR-ZnEDTA color-forming reagents. Other metal ions are detected by means of PAR and Chromazurol S color-forming reagents. Calcium and magnesium distribution coefficients on partially sulfonated XAD-2 as functions of ammonium chloride andmore » ethylenediammonium chloride concentration are given together with distribution coefficients of other metal ions. Methods for the selective elution of interfering metal ions prior to the elution of calcium and magnesium are described. Beryllium and aluminum are selectively eluted with sulfosalicylic acid. Those elements forming anionic chloride complexes are selectively eluted with HCl-acetone. Nickel is selectively eluted with HCl-acetone-dimethylglyoxime. Synthetic samples containing calcium and magnesium, both alone and in combination with alkali metals, strontium, barium, beryllium, aluminum, transition metals, and rare earths, are analyzed. Hard water samples are analyzed for calcium and magnesium and the results compared to those obtained by EDTA titration, atomic absorption spectroscopy, and plasma emission spectroscopy. Several clinical serum samples are analyzed for calcium and magnesium and the results compared to those obtained by atomic absorption spectroscopy.« less

  3. Determination of Chromium(III), Chromium(VI), and Chromium(III) acetylacetonate in water by ion-exchange disk extraction/metal furnace atomic absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Kamakura, Nao; Inui, Tetsuo; Kitano, Masaru; Nakamura, Toshihiro

    A new method for the separate determination of Chromium(III) (Cr(III)), Chromium(VI) (Cr(VI)), and Cr(III) acetylacetonate (Cr(acac)3) in water was developed using a cation-exchange extraction disk (CED) and an anion-exchange extraction disk (AED) combined with metal furnace atomic absorption spectrometry (MFAAS). A 100-mL water sample was adjusted to pH 5.6 and passed through the CED placed on the AED. Cr(acac)3 and Cr(III) were adsorbed on the CED, and Cr(VI) was adsorbed on the AED. The adsorbed Cr(acac)3 was eluted with 50 mL of carbon tetrachloride, followed by the elution of Cr(III) with 50 mL of 3 mol L- 1 nitric acid. Cr(VI) was eluted with 50 mL of 3 mol L- 1 nitric acid. The chemical species of Cr eluted from the CED with carbon tetrachloride was identified as Cr(acac)3 using infrared spectroscopy. The eluate of Cr(acac)3 was diluted to 100 mL with carbon tetrachloride, and those of Cr(III) and Cr(VI) were diluted to 100 mL with deionized water. All of the solutions were subsequently analyzed by MFAAS. The calibration curve for the Cr(acac)3 aqueous solutions exhibited good linearity in the range of 0.1 to 1 ng. The detection limit of Cr, which corresponded to three times the standard deviation (n = 10) of the blank values, was 20 pg. The recovery test for Cr(III), Cr(VI), and Cr(acac)3 exhibited desirable results (96.0%-107%) when 5 μg of each species (50 μg L- 1) was added to 100 mL water samples (i.e., tap water, rainwater, and bottled drinking water). In a humic acid solution, Cr(acac)3 was quantitatively recovered (103%), but Cr(III) and Cr(VI) exhibited poor recoveries (i.e., 84.8% and 78.4%, respectively).

  4. Elution of Re-188 from W-188/Re-188 generators with salts of weak acids permits efficient concentration to low volumes using a new tandem cation/anion exchange system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Guhlke, S.; Beets, A.L.; Knapp, F.F. Jr.

    1997-05-01

    Re-188, available from a W-188/Re-188 generator, is an important therapeutic radioisotope for bone pain palliation, cancer therapy and intravascular brachytherapy, etc. Because of the relatively low specific activity of reactor-produced W-188 (ORNL HFIR, 296-370 MBq mCi/mg W-186 for 2 cycles), methods of concentrating the Re-188 bolus (10-12 mL) from clinical scale (18.5-37 BGq W-188) generators (5-6 gm alumina) are thus very important. We demonstrate for the first time a new strategy of generator elution with salts of weak acids and specific perrhenate anion {open_quotes}trapping{close_quotes} with QMA anion columns. Re-188 perrhenate is efficiently eluted (65-75%) from the alumina-based generator with 0.15-0.3more » M ammonium acetate. An acetic acid solution of Re-188 perrhenic acid is obtained by subsequent on-line passage of the generator eluant through a DOWEX AG 50Wx8 (200-400 mesh, H{sup +} form) column. Since acetic acid is not ionized (< 0.001%) at this pH (< pK{sub a} = 4.76) the perrhenate anion is then specifically trapped on a QMA {open_quotes}Light{close_quotes} anion extraction column. QMA elution with 0.9% NaCl, provides Re-188 perrhenate solution in <1 mL. Concentration of 10-20 mL of Re-188 solution (> 15 BGq) in <1 mL has been demonstrated using this simple new approach, which is also effective for concentration of Tc-99m from low specific activity Mo-99 (n,y) generators. The cation/anion tandem system is inexpensive and disposable and use can be easily automated. The availability of this very simple, efficient system is important for broad use of rhenium-188.« less

  5. Methods for the separation of rhenium, osmium and molybdenum applicable to isotope geochemistry

    USGS Publications Warehouse

    Morgan, J.W.; Golightly, D.W.; Dorrzapf, A.F.

    1991-01-01

    Effective methods are described for the chemical separation of rhenium, osmium and molybdenum. The methods are based on distillation and anion-exchange chromatography, and have been the basis for rhenium-osmium isotope studies of ore deposits and meteorites. Successful anion-exchange separation of osmium requires both recognition and careful control of the osmium species in solution; thus, distillation of osmium tetroxide from a mixture of sulfuric acid and hydrogen peroxide is preferred to anion-exchange. Distribution coefficients measured for perrhenate in sulfuric acid media are sufficiently high (Kd > 500) for rhenium to be directly loaded onto an ion-exchange column from a distillation residue and subsequently eluted with nitric acid. Polymerization of molybdenum species during elution is prevented by use of a solution that is 1M in hydrochloric acid and 1M in sodium chloride. ?? 1991.

  6. Evaluation of human papillomavirus detection by Abbott m2000 system on samples collected by FTA Elute™ Card in a Chinese HIV-1 positive population.

    PubMed

    Qin, Yu; Zhang, Hongyun; Marlowe, Natalia; Fei, Mandong; Yu, Judy; Lei, Xiaoqin; Yu, Lulu; Zhang, Jia; Cao, Di; Ma, Li; Chen, Wen

    2016-12-01

    HIV+/AIDS women have an increased risk of developing into CIN and cervical cancer compared to the general population. Limited medical resource and the lack of AIDS relevant knowledge impair the coverage and efficiency of cervical cancer screening. To compare the clinical performance of self-collected dry storage medium (FTA Elute card) and physician-collected PreservCyt medium in detection of high risk human papillomavirus (HR HPV) among HIV-1 positive population. Three hundred HIV-1 positive women (aged 25-65) were recruited from Yunnan infectious hospital. Two cervicovaginal samples were collected from each participant: one was collected by the women themselves and applied on a FTA Elute card; the other one was collected by a physician and stored in PreservCyt solution. All the samples were tested for 14 HR HPV using Abbott RealTime High Risk HPV assay. Biopsies were taken for histological diagnosis if any abnormal impression was noticed under colposcopy. 291 (97.0%) of participants were eligible for this study. 101 (34.70%) participants were found HR HPV positive in both FTA card and PreservCyt samples, and 19 (6.53%) women were diagnosed as CIN2+. The HR HPV positive rate on samples collected by FTA Elute card and PreservCyt solution was 42.61% and 39.86%, respectively. The overall agreement was 87% (kappa=0.731) between FTA card and PreservCyt. The clinical sensitivity and specificity of FTA card and PreservCyt were 100%, 61.39% and 100%, 64.33%, respectively. In this study, FTA Elute card demonstrated a good performance on self-collected sample for HR HPV detection in HIV-1 positive population. For the women from low-resource area with HIV-1 infection, FTA Elute card could be an attractive sample collection method for cervical cancer screening. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. [Influences of the mobile phase constitution, salt concentration and pH value on retention characters of proteins on the metal chelate column].

    PubMed

    Li, R; Di, Z M; Chen, G L

    2001-09-01

    The effects of the nature and concentration of salts, pH value and competitive eluent in the mobile phase on the protein retention have been systematically investigated. A mathematical expression describing the protein retention in metal chelate chromatography has been derived. It is proposed that the eluting power of the salt solution can be expressed by the eluent strength exponent epsilon. According to the retention characters of protein under different chromatographic conditions, the interaction between the various metal chelate ligands and proteins is discussed. The protein retention on the metal chelate column is a cooperative interactions of coordination, electrostatic and hydrophobic interaction. For the strong combined metal column with proteins such as IDA-Cu, the coordination is the most important, and the electrostatic interaction is secondary in chromatographic process. However, for the weak combined metal columns with proteins such as IDA-Ni, IDA-Co and IDA-Zn, the electrostatic interaction between the metal chelate ligands and proteins is the chief one, while the coordination is the next in importance. When the mobile phase contains high concentration of salt which can't form complex with the immobilized metal, the hydrophobic interaction between the protein and stationary phase will be increased. As the interaction between the metal chelate ligand and proteins relates to chromatographic operating conditions closely, different elution processes may be selected for different metal chelate columns. The gradient elution is generally performed by the low concentration of salt or different pH for weakly combined columns with proteins, however the competitive elution procedure is commonly utilized for strongly combined column. The experiment showed that NH3 is an excellent competitive eluent. It isn't only give the efficient separation of proteins, but also has the advantages of cheapness, less bleeding of the immobilized metals and ease of controlling NH3 concentration. The interaction between the metal chelate ligand and proteins and the selectivity of metal chelate chromatography can be changed through changing chromatographic conditions.

  8. Purification and labeling strategies for (68)Ga from (68)Ge/ (68)Ga generator eluate.

    PubMed

    Mueller, Dirk; Klette, Ingo; Baum, Richard P

    2013-01-01

    For successful labeling, (68)Ge/(68)Ga generator eluate has to be concentrated (from 10 mL or more to less than 1 mL) and to be purified of metallic impurities, especially Fe(III), and (68)Ge breakthrough. Anionic, cationic and fractional elution methods are well known. We describe two new methods: (1) a combined cationic-anionic purification and (2) an easy-to-use and reliable cationic purification with NaCl solution. Using the first method, (68)Ga from 10 mL generator eluate was collected on a SCX cartridge, then eluted with 1.0 mL 5.5 M HCl directly on an anion exchanger (30 mg AG1X8). After drying with a stream of helium, (68)Ga was eluted with 0.4 mL water into the reaction vial. We provide as an example labeling of BPAMD. Using the second method, (68)Ga from 10 mL generator eluate was collected on a SCX cartridge, then eluted with a hydrochloric solution of sodium chloride (0.5 mL 5 M NaCl, 12.5 μL 5.5 M HCl) into the reaction vial, containing 40 μg DOTATOC and 0.5 mL 1 M ammonium acetate buffer pH 4.5. After heating for 7 min at 90°C, the reaction was finished. Radiochemical purity was higher than 95% without further purification. No (68)Ge breakthrough was found in the final product.

  9. Use of entrapment and high-performance affinity chromatography to compare the binding of drugs and site-specific probes with normal and glycated human serum albumin

    PubMed Central

    Jackson, Abby J.; Anguizola, Jeanethe; Pfaunmiller, Erika L.; Hage, David S.

    2013-01-01

    Protein entrapment and high-performance affinity chromatography were used with zonal elution to examine the changes in binding that occurred for site-specific probes and various sulfonylurea drugs with normal and glycated forms of human serum albumin (HSA). Samples of this protein in a soluble form were physically entrapped within porous silica particles by using glycogen-capped hydrazide-activated silica; these supports were then placed into 1.0 cm × 2.1 mm inner diameter columns. Initial zonal elution studies were performed using (R)-warfarin and L-tryptophan as probes for Sudlow sites I and II (i.e., the major drug binding sites of HSA), giving quantitative measures of binding affinities in good agreement with literature values. It was also found for solutes with multisite binding to the same proteins, such as many sulfonylurea drugs, that this method could be used to estimate the global affinity of the solute for the entrapped protein. This entrapment and zonal approach provided retention information with precisions of ±0.1–3.3% (± one standard deviation) and elution within 0.50–3.00 min for solutes with binding affinities of 1 × 104–3 × 105 M−1. Each entrapped-protein column was used for many binding studies, which decreased the cost and amount of protein needed per injection (e.g., the equivalent of only 125–145 pmol of immobilized HSA or glycated HSA per injection over 60 sample application cycles). This method can be adapted for use with other proteins and solutes and should be valuable in high-throughput screening or quantitative studies of drug–protein binding or related biointeractions. PMID:23657448

  10. Gradient elution moving boundary electrophoresis enables rapid analysis of acids in complex biomass-derived streams

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Munson, Matthew S.; Karp, Eric M.; Nimlos, Claire T.

    Biomass conversion processes such as pretreatment, liquefaction, and pyrolysis often produce complex mixtures of intermediates that are a substantial challenge to analyze rapidly and reliably. To characterize these streams more comprehensively and efficiently, new techniques are needed to track species through biomass deconstruction and conversion processes. Here, we present the application of an emerging analytical method, gradient elution moving boundary electrophoresis (GEMBE), to quantify a suite of acids in a complex, biomass-derived streams from alkaline pretreatment of corn stover. GEMBE offers distinct advantages over common chromatography-spectrometry analytical approaches in terms of analysis time, sample preparation requirements, and cost of equipment.more » As demonstrated here, GEMBE is able to track 17 distinct compounds (oxalate, formate, succinate, malate, acetate, glycolate, protocatechuate, 3-hydroxypropanoate, lactate, glycerate, 2-hydroxybutanoate, 4-hydroxybenzoate, vanillate, p-coumarate, ferulate, sinapate, and acetovanillone). The lower limit of detection was compound dependent and ranged between 0.9 and 3.5 umol/L. Results from GEMBE were similar to recent results from an orthogonal method based on GCxGC-TOF/MS. Altogether, GEMBE offers a rapid, robust approach to analyze complex biomass-derived samples, and given the ease and convenience of deployment, may offer an analytical solution for online tracking of multiple types of biomass streams.« less

  11. Gradient elution moving boundary electrophoresis enables rapid analysis of acids in complex biomass-derived streams

    DOE PAGES

    Munson, Matthew S.; Karp, Eric M.; Nimlos, Claire T.; ...

    2016-09-27

    Biomass conversion processes such as pretreatment, liquefaction, and pyrolysis often produce complex mixtures of intermediates that are a substantial challenge to analyze rapidly and reliably. To characterize these streams more comprehensively and efficiently, new techniques are needed to track species through biomass deconstruction and conversion processes. Here, we present the application of an emerging analytical method, gradient elution moving boundary electrophoresis (GEMBE), to quantify a suite of acids in a complex, biomass-derived streams from alkaline pretreatment of corn stover. GEMBE offers distinct advantages over common chromatography-spectrometry analytical approaches in terms of analysis time, sample preparation requirements, and cost of equipment.more » As demonstrated here, GEMBE is able to track 17 distinct compounds (oxalate, formate, succinate, malate, acetate, glycolate, protocatechuate, 3-hydroxypropanoate, lactate, glycerate, 2-hydroxybutanoate, 4-hydroxybenzoate, vanillate, p-coumarate, ferulate, sinapate, and acetovanillone). The lower limit of detection was compound dependent and ranged between 0.9 and 3.5 umol/L. Results from GEMBE were similar to recent results from an orthogonal method based on GCxGC-TOF/MS. Altogether, GEMBE offers a rapid, robust approach to analyze complex biomass-derived samples, and given the ease and convenience of deployment, may offer an analytical solution for online tracking of multiple types of biomass streams.« less

  12. Generator for gallium-68 and compositions obtained therefrom

    DOEpatents

    Neirinckx, Rudi D.; Davis, Michael A.

    1981-01-01

    A generator for obtaining radioactive gallium-68 from germanium-68 bound in a resin containing unsubstituted phenolic hydroxyl groups. The germanium-68 is loaded into the resin from an aqueous solution of the germanium-68. A physiologically acceptable solution of gallium-68 having an activity of 0.1 to 50 millicuries per milliliter of gallium-68 solution is obtained. The solution is obtained from the bound germanium-68 which forms gallium-68 in situ by eluting the column with a hydrochloric acid solution to form an acidic solution of gallium-68. The acidic solution of gallium-68 can be neutralized.

  13. Cation exchange concentraion of the Americium product from TRUEX

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barney, G.S.; Cooper, T.D.; Fisher, F.D.

    1991-06-01

    A transuranic extraction (TRUEX) process has been developed to separate and recover plutonium, americium, and other transuranic (TRU) elements from acid wastes. The main objective of the process is to reduce the effluent to below the TRU limit for actinide concentrations (<100 nCi/g of material) so it can be disposed of inexpensively. The process yields a dilute nitric acid stream containing low concentrations of the extracted americium product. This solution also contains residual plutonium and trace amounts of iron. The americium will be absorbed into a cation exchange resin bed to concentrate it for disposal or for future use. Themore » overall objective of these laboratory tests was to determine the performance of the cation exchange process under expected conditions of the TRUEX process. Effects of acid, iron, and americium concentrations on americium absorption on the resin were determined. Distribution coefficients for americium absorption from acide solutions on the resin were measured using batch equilibrations. Batch equilibrations were also used to measure americium absorption in the presence of complexants. This data will be used to identify complexants and solution conditions that can be used to elute the americium from the columns. The rate of absorption was measured by passing solutions containing americium through small columns of resin, varying the flowrates, and measuring the concentrations of americium in the effluent. The rate data will be used to estimate the minimum bed size of the columns required to concentrate the americium product. 11 refs. , 10 figs., 2 tabs.« less

  14. Effective removal of cesium from wastewater solutions using an innovative low-cost adsorbent developed from sewage sludge molten slag.

    PubMed

    Khandaker, Shahjalal; Toyohara, Yusaku; Kamida, Seiya; Kuba, Takahiro

    2018-06-01

    This study investigates the effective removal of cesium (Cs) from aqueous solution using sewage sludge molten (SSM) slag that has undergone the surface modification with alkali (NaOH) hydrothermal treatment. The raw and modified slags were characterised systematically using the BET method, the FESEM, the XRF, the XRD spectroscopy and the CEC analysis to understand the physicochemical changes of the materials, and its sensitivity to Cs ions adsorption. Batch adsorption experiments were carried out to investigate the effects of adsorbent dose, contact time, solution pH, different initial Cs concentrations, temperature and the effect of competitive ions on Cs adsorption. The adsorption isotherm, kinetic and thermodynamic studies were also evaluated based on the experimental results. A higher Cs removal efficiency of almost 100% (for 20-100 mg/L of initial concentration) was achieved by the modified SSM slag, and the maximum adsorption capacity was found to be 52.36 mg/g. Several types of synthetic zeolites such as zeolite X, zeolite Y, zeolite A, and sodalite were formed on surface of the modified slag through the modification process which might be enhanced the Cs adsorption capacity. Kinetic parameters were fitted by the pseudo-second order model. The adsorption isotherms data of modified slag were well-fitted to the Langmuir (R 2  = 0.989) and Freundlich isotherms (R 2  = 0.988). The thermodynamic studies indicated that the adsorption process by the modified slag was spontaneous and exothermic. In the competitive ions effect, the modified slag effectively captured the Cs ion in the presence of Na + and K + , especially at their lower concentrations. Moreover, the modified slag was reused for several cycles after the successful elution process with an appropriate eluting agent (0.5 M H 2 SO 4 ), without deterioration of its original performance. Therefore, the SSM modified slag could be effectively used as a low-cost potential adsorbent for high Cs adsorption from wastewater. Copyright © 2018 Elsevier Ltd. All rights reserved.

  15. The design of a new concept chromatography column.

    PubMed

    Camenzuli, Michelle; Ritchie, Harald J; Ladine, James R; Shalliker, R Andrew

    2011-12-21

    Active Flow Management is a new separation technique whereby the flow of mobile phase and the injection of sample are introduced to the column in a manner that allows migration according to the principles of the infinite diameter column. A segmented flow outlet fitting allows for the separation of solvent or solute that elutes along the central radial section of the column from that of the sample or solvent that elutes along the wall region of the column. Separation efficiency on the analytical scale is increased by 25% with an increase in sensitivity by as much as 52% compared to conventional separations.

  16. Assessment study of ion-exchange chromatography combined with solution X-ray scattering measurement for protein characterization.

    PubMed

    Watanabe, Yasushi

    2018-03-02

    The performance of ion-exchange chromatography combined with small-angle X-ray scattering measurement was evaluated by characterization of the hen egg white lysozyme as a model protein. The X-ray transmittance was estimated using a micro-ionization chamber equipped with a sample cell holder for the real-time monitoring of the X-ray beam strength through the salt gradient elution. The radius of gyration of the eluted protein was estimated to be 1.50 ± 0.06 (n = 3) nm and 1.4 ± 0.1 nm as the value at the zero protein concentration. By using the X-ray transmittance values for the scattering intensity correction, the molecular weight of the eluted protein was estimated to be 15,200 ± 500 (n = 3) and 14,400 ± 200 as the value at the zero protein concentration. These values are close to those of the monomer of this protein. The ion-exchange chromatography combined with the small-angle X-ray scattering measurement system equipped with the X-ray transmittance monitor is a reliable method for protein characterization in solution. Copyright © 2018 Elsevier B.V. All rights reserved.

  17. The group separation of the rare-earth elements and yttrium from geologic materials by cation-exchange chromatography

    USGS Publications Warehouse

    Crock, J.G.; Lichte, F.E.; Wildeman, T.R.

    1984-01-01

    Demand is increasing for the determination of the rare-earth elements (REE) and yttrium in geologic materials. Due to their low natural abundance in many materials and the interferences that occur in many methods of determination, a separation procedure utilizing gradient strong-acid cation-exchange chromatography is often used to preconcentrate and isolate these elements from the host-rock matrix. Two separate gradient strong-acid cation-exchange procedures were characterized and the major elements as well as those elements thought to provide the greatest interference for the determination of the REE in geologic materials were tested for separation from the REE. Simultaneous inductively coupled argon plasma-atomic emission spectroscopy (ICAP-AES) measurements were used to construct the chromatograms for the elution studies, allowing the elution patterns of all the elements of interest to be determined in a single fraction of eluent. As a rock matrix, U.S. Geological Survey standard reference BCR-1 basalt was digested using both an acid decomposition procedure and a lithium metaborate fusion. Hydrochloric and nitric acids were tested as eluents and chromatograms were plotted using the ICAP-AES data; and we observed substantial differences in the elution patterns of the REE and as well as in the solution patterns of Ba, Ca, Fe and Sr. The nitric acid elution required substantially less eluent to elute the REE and Y as a group when compared to the hydrochloric acid elution, and provided a clearer separation of the REE from interfering and matrix elements. ?? 1984.

  18. Elution of monomer from different bulk fill dental composite resins.

    PubMed

    Cebe, Mehmet Ata; Cebe, Fatma; Cengiz, Mehmet Fatih; Cetin, Ali Rıza; Arpag, Osman Fatih; Ozturk, Bora

    2015-07-01

    The purpose of this study was to evaluate the elution of Bis-GMA, TEGDMA, HEMA, and Bis-EMA monomers from six bulk fill composite resins over four different time periods, using HPLC. Six different composite resin materials were used in the present study: Tetric Evo Ceram Bulk Fill (Ivoclar Vivadent, Amherst, NY), X-tra Fill (VOCO, Cuxhaven, Germany), Sonic Fill (Kerr, Orange, CA, USA), Filtek Bulk Fill (3M ESPE Dental Product, St. Paul, MN), SDR (Dentsply, Konstanz, Germany), EQUIA (GC America INC, Alsip, IL). The samples (4mm thickness, 5mm diameter) were prepared and polymerized for 20s with a light emitted diode unit. After fabrication, each sample was immediately immersed in 75wt% ethanol/water solution used as extraction fluid and stored in the amber colored bottles at room temperature. Ethanol/water samples were taken (0.5mL) at predefined time intervals:10m (T1), 1h (T2), 24h (T3) and 30 days (T4). These samples were analyzed by HPLC. The obtained data were analyzed with one-way ANOVA and Tukey HSD at significance level of p<0.05. Amount of eluted Bis-EMA and Bis-GMA from Tetric Evo Ceram Bulk Fill and amount of eluted TEGDMA and HEMA from X-tra Fill higher than others composites (p<0.05). Residual monomers were eluted from bulk fill composite resins in all time periods and the amount of eluted monomers was increased with time. Copyright © 2015 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  19. Dithizone-functionalized solid phase extraction-displacement elution-high performance liquid chromatography-inductively coupled plasma mass spectrometry for mercury speciation in water samples.

    PubMed

    Yin, Yong-guang; Chen, Ming; Peng, Jin-feng; Liu, Jing-fu; Jiang, Gui-bin

    2010-06-15

    A novel and simple solid phase extraction (SPE)-high performance liquid chromatography (HPLC)-inductively coupled plasma mass spectrometry (ICP-MS) method was developed for determination of inorganic mercury (IHg), methylmercury MeHg and ethylmercury (EtHg) in water samples in the present work. The procedure involves pre-functionalization of the commercially available C18 SPE column with dithizone, loading water sample, displacement elution of mercury species by Na(2)S(2)O(3) solution, followed by HPLC-ICP-MS determination. Characterization and optimization of operation parameters of this new SPE procedure were discussed, including eluting reagent selection, concentration of eluting reagent, volume of eluting reagent, effect of NaCl and humic acid in sample matrix. At optimized conditions, the detection limits of mercury species for 100mL water sample were about 3ngL(-1) and the average recoveries were 93.7, 83.4, and 71.7% for MeHg, IHg and EtHg, respectively, by spiking 0.2microgL(-1) mercury species into de-ion water. Stability experiment reveals that both the dithizone-functionalized SPE cartridge and the mercury species incorporated were stable in the storage procedure. These results obtained demonstrate that SPE-HPLC-ICP-MS is a simple and sensitive technique for the determination of mercury species at trace level in water samples with high reproducibility and accuracy.

  20. ZIRCONIUM PHOSPHATE ADSORPTION METHOD

    DOEpatents

    Russell, E.R.; Adamson, A.S.; Schubert, J.; Boyd, G.E.

    1958-11-01

    A method is presented for separating plutonium values from fission product values in aqueous acidic solution. This is accomplished by flowing the solutlon containing such values through a bed of zirconium orthophosphate. Any fission products adsorbed can subsequently be eluted by washing the column with a solution of 2N HNO/sub 3/ and O.lN H/sub 3/PO/sub 4/. Plutonium values may subsequently be desorbed by contacting the column with a solution of 7N HNO/sub 3/ .

  1. Elution of Uranium and Transition Metals from Amidoxime-Based Polymer Adsorbents for Sequestering Uranium from Seawater

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pan, Horng-Bin; Kuo, Li-Jung; Wai, Chien M.

    2015-11-30

    High-surface-area amidoxime and carboxylic acid grafted polymer adsorbents developed at Oak Ridge National Laboratory were tested for sequestering uranium in a flowing seawater flume system at the PNNL-Marine Sciences Laboratory. FTIR spectra indicate that a KOH conditioning process is necessary to remove the proton from the carboxylic acid and make the sorbent effective for sequestering uranium from seawater. The alkaline conditioning process also converts the amidoxime groups to carboxylate groups in the adsorbent. Both Na 2CO 3-H 2O 2 and hydrochloric acid elution methods can remove ~95% of the uranium sequestered by the adsorbent after 42 days of exposure inmore » real seawater. The Na 2CO 3-H 2O 2 elution method is more selective for uranium than conventional acid elution. Iron and vanadium are the two major transition metals competing with uranium for adsorption to the amidoxime-based adsorbents in real seawater.« less

  2. Production of all trans-beta-carotene by using impinging flow of supercritical carbon dioxide anti-solvent pulverization.

    PubMed

    Shen, Yi-Chen; Chng, Lee-Muei; Wang, Yuan-Chuen; Shieh, Chwen-Jen; Lin, Kuo-Li; Hsu, Shih-Lan; Chou, Hong-Nong; Chang, Chieh-Ming J

    2012-12-28

    This work investigated column elution chromatography coupled with supercritical anti-solvent precipitation to produce carotenoid rich microsized particulates from microalgal Dunaliella salina species. The extract contained carotenoids ranging from 61.3 mg/g(salina) to 72.5 mg/g(salina) using ultrasonic stirred ethyl ether or tetrahydrofuran (THF) extraction. When 10 L of ethyl alcohol was employed to elute the THF extract, purity of trans-β-carotene is 823.6 mg/g with a recovery of 86.2%. It was found that the supercritical anti-solvent of THF solution at 160 bar and 318 K produced powdered particulates with a purity of carotenoids above 90%. Subsequently, a central composite response surface design method was used to design supercritical anti-solvent precipitation of carotenoid-rich THF solution. This was accomplished by increasing the pressure from 140 bar to 180 bar and the time from 40 min to 60 min at a feed flow rate of 0.2 mL/min. A CO(2) flow rate of 15 L/min and a temperature of 318 K were also used to determine the effects on purity and recovery of trans-β-carotene. The combined process produced micronized precipitates with a mean particle size ranging from 3.5 μm to 19 μm and the purity of trans-β-carotene attained was 926.8 mg/g with a recovery of 54%. Copyright © 2012 Elsevier B.V. All rights reserved.

  3. Adsorptive separation in bioprocess engineering

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huang, E.W.Y.

    1987-01-01

    The invention and development of an energy-efficient separation technique for recovery of desired chemicals from biomass conversion would greatly enhance the economic viability of this bioprocess. Adsorptive separation of several chemicals from aqueous solution was studied in this thesis. The desired species were recovered from the dilute aqueous solution by using crosslinked polyvinylpyridine resin to effect selective sorption. The sorbed chemicals were then removed from the resin by either thermal regeneration or elution with some appropriate desorbents. The effects of temperature, pH value, and solute concentration on resin swelling were investigated. The adsorption equilibrium isotherms, resin capacities and resin selectivitiesmore » of methanol, ethanol, 1-propanol, isopropanol, glycerol, acetone, 1-butanol, tert-butanol, and 2,3-butanediol were determined to study the homologies. Furthermore, acetic acid, butyric acid, hydrochloric acid, lactic acid, and sulfuric acid were recovered from very dilute aqueous solutions. The concentration of the sorbed chemical in the stationary phase can be many times higher than in the mobile phase for some acids. Finally, different types of equilibrium isotherms were used to fit the experimental data. A mathematical model was developed by using the theory of interference to predict the breakthrough curves and the process efficiency to provide information for large-scale process design and development.« less

  4. Method for preparing high specific activity 177Lu

    DOEpatents

    Mirzadeh, Saed; Du, Miting; Beets, Arnold L.; Knapp, Jr., Furn F.

    2004-04-06

    A method of separating lutetium from a solution containing Lu and Yb, particularly reactor-produced .sup.177 Lu and .sup.177 Yb, includes the steps of: providing a chromatographic separation apparatus containing LN resin; loading the apparatus with a solution containing Lu and Yb; and eluting the apparatus to chromatographically separate the Lu and the Yb in order to produce high-specific-activity .sup.177 Yb.

  5. Gas amplified ionization detector for gas chromatography

    DOEpatents

    Huston, Gregg C.

    1992-01-01

    A gas-amplified ionization detector for gas chromatrography which possesses increased sensitivity and a very fast response time. Solutes eluding from a gas chromatographic column are ionized by UV photoionization of matter eluting therefrom. The detector is capable of generating easily measured voltage signals by gas amplification/multiplication of electron products resulting from the UV photoionization of at least a portion of each solute passing through the detector.

  6. Uranium chemistry in stack solutions and leachates of phosphogypsum disposed at a coastal area in Cyprus.

    PubMed

    Lysandrou, M; Pashalidis, I

    2008-02-01

    The effect of the matrix composition (main constituents) on the concentration and chemical behavior of uranium in phosphogypsum stack solutions and leachates has been investigated. Solid and aqueous samples were taken from three different sub-areas of a phosphogypsum stack at a coastal area in Vasilikos (Cyprus). The sub-areas are characterized whether by their acidity (e.g. "aged" and "non-aged" phosphogypsum) or by their salt content, originating from pulping water during wet stacking or (after deposition) from the adjacent sea. Measurements in stack solutions and leachates showed that phosphogypsum characteristics affect both, the concentration and the chemical behavior of uranium in solution. Uranium concentration in solutions of increased salinity is up to three orders of magnitude higher than in solutions of low salinity and this is attributed to the effect of ionic strength on the solubility of phosphogypsum. Modelling showed that uranium in stack solutions is predominantly present in the form of uranium(VI) phosphate complexes (e.g. UO(2)(H(2)PO(4))(2), UO(2)HPO(4)), whereas in leachates uranium(VI) fluoro complexes (e.g. UO(2)F(2), UO(2)F(3)(-)) are predominant in solution. The latter indicates that elution of uranium from phosphogypsum takes places most probably in the form of fluoro complexes. Both, effective elution by saline water and direct migration of uranium to the sea, where it forms very stable uranium(VI) carbonato complexes, indicate that the adjacent sea will be the final receptor of uranium released from Vasilikos phosphogypsum.

  7. Preparation of paclitaxel/chitosan co-assembled core-shell nanofibers for drug-eluting stent

    NASA Astrophysics Data System (ADS)

    Tang, Jing; Liu, Yongjia; Zhu, Bangshang; Su, Yue; Zhu, Xinyuan

    2017-01-01

    The paclitaxel/chitosan (PTX/CS) core-shell nanofibers (NFs) are easily prepared by co-assembly of PTX and CS and used in drug-eluting stent. The mixture solution of PTX (dissolved in ethanol) and CS (dissolved in 1% acetic acid water solution) under sonication will make the formation of NFs, in which small molecule PTX co-assembles with biomacromolecular CS through non-covalent interactions. The obtained NFs are tens to hundreds nanometers in diameter and millimeter level in length. Furthermore, the structure of PTX/CS NFs was characterized by confocal laser scanning microscopy (CLSM), zeta potential, X-ray photoelectron spectroscopy (XPS) and nanoscale infra-red (nanoIR), which provided evidences demonstrated that PTX/CS NFs are core-shell structures. The 'shell' of CS wrapped outside of the NFs, while PTX is located in the core. Thus it resulted in high drug loading content (>40 wt.%). The well-controlled drug release, low cytotoxicity and good haemocompatibility were also found in drug carrier system of PTX/CS NFs. In addition, the hydrophilic and flexible properties of NFs make them easily coating and filming on stent to prepare drug-eluting stent (DES). Therefore, this study provides a convenient method to prepare high PTX loaded NFs, which is a promising nano-drug carrier used for DES and other biomedical applications. The possible molecular mechanism of PTX and CS co-assembly and core-shell nanofiber formation is also explored.

  8. Uncertainty Estimation for the Determination of Ni, Pb and Al in Natural Water Samples by SPE-ICP-OES

    NASA Astrophysics Data System (ADS)

    Ghorbani, A.; Farahani, M. Mahmoodi; Rabbani, M.; Aflaki, F.; Waqifhosain, Syed

    2008-01-01

    In this paper we propose uncertainty estimation for the analytical results we obtained from determination of Ni, Pb and Al by solidphase extraction and inductively coupled plasma optical emission spectrometry (SPE-ICP-OES). The procedure is based on the retention of analytes in the form of 8-hydroxyquinoline (8-HQ) complexes on a mini column of XAD-4 resin and subsequent elution with nitric acid. The influence of various analytical parameters including the amount of solid phase, pH, elution factors (concentration and volume of eluting solution), volume of sample solution, and amount of ligand on the extraction efficiency of analytes was investigated. To estimate the uncertainty of analytical result obtained, we propose assessing trueness by employing spiked sample. Two types of bias are calculated in the assessment of trueness: a proportional bias and a constant bias. We applied Nested design for calculating proportional bias and Youden method to calculate the constant bias. The results we obtained for proportional bias are calculated from spiked samples. In this case, the concentration found is plotted against the concentration added and the slop of standard addition curve is an estimate of the method recovery. Estimated method of average recovery in Karaj river water is: (1.004±0.0085) for Ni, (0.999±0.010) for Pb and (0.987±0.008) for Al.

  9. Application and comparison of high performance liquid chromatography and high speed counter-current chromatography in enantioseparation of (±)-2-phenylpropionic acid.

    PubMed

    Tong, Shengqiang; Zheng, Ye; Yan, Jizhong

    2013-03-15

    High performance liquid chromatography (HPLC) and high speed counter-current chromatography (HSCCC) were applied and compared in enantioseparation of 2-phenylpropionic acid (2-PPA) when hydroxypropyl-β-cyclodextrin (HP-β-CD) was used as chiral mobile phase additive. For HPLC, the enantioseparation was achieved on ODS C(18) reverse phase column and the mobile phase was 25 mmol L(-1) HP-β-CD aqueous buffer solution (pH 4.0, adjusted with triethylamine): methanol: glacial acetic acid (85:15:0.5 (v/v/v)). For HSCCC, the two-phase solvent system was composed of n-hexane-ethyl acetate-0.1 mol L(-1) phosphate buffer solution pH2.67 (5:5:10 for isocratic elution and 8:2:10 for recycling elution (v/v/v)) added with 0.1 mol L(-1) HP-β-CD. The key parameters, such as a substitution degree of HP-β-CD, the concentration of HP-β-CD, pH value of the aqueous phase and the temperature were optimized for both separation methods. Using the optimum conditions a complete HSCCC enantioseparation of 40 mg of 2-propylpropionic acid in a recycling elution mode gave 15-18 mg of (+)-2-PPA and (-)-2-PPA enantiomers with 95-98% purity and 85-93% recovery. Copyright © 2013 Elsevier B.V. All rights reserved.

  10. Towards enhanced automated elution systems for waterborne protozoa using megasonic energy.

    PubMed

    Horton, B; Katzer, F; Desmulliez, M P Y; Bridle, H L

    2018-02-01

    Continuous and reliable monitoring of water sources for human consumption is imperative for public health. For protozoa, which cannot be multiplied efficiently in laboratory settings, concentration and recovery steps are key to a successful detection procedure. Recently, the use of megasonic energy was demonstrated to recover Cryptosporidium from commonly used water industry filtration procedures, forming thereby a basis for a simplified and cost effective method of elution of pathogens. In this article, we report the benefits of incorporating megasonic sonication into the current methodologies of Giardia duodenalis elution from an internationally approved filtration and elution system used within the water industry, the Filta-Max®. Megasonic energy assisted elution has many benefits over current methods since a smaller final volume of eluent allows removal of time-consuming centrifugation steps and reduces manual involvement resulting in a potentially more consistent and more cost-effective method. We also show that megasonic sonication of G. duodenalis cysts provides the option of a less damaging elution method compared to the standard Filta-Max® operation, although the elution from filter matrices is not currently fully optimised. A notable decrease in recovery of damaged cysts was observed in megasonic processed samples, potentially increasing the abilities of further genetic identification options upon isolation of the parasite from a filter sample. This work paves the way for the development of a fully automated and more cost-effective elution method of Giardia from water samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Strategies for the depyrogenation of contaminated immunoglobulin G solutions by histidine-immobilized hollow fiber membrane.

    PubMed

    Legallais, C; Anspach, F B; Bueno, S M; Haupt, K; Vijayalakshmi, M A

    1997-03-28

    The depyrogenation of different IgG solutions using the histidine-linked hollow fiber membrane developed in our laboratory is presented here. Three strategies for endotoxin (ET) removal were investigated according to the immobilized histidine's ability to bind different immunoglobulins: (1) ET removal from 1 mg/ml non histidine-binding mouse monoclonal IgG1 (MabCD4) solution was achieved in the presence of acetate buffer (pH 5.0) without any protein loss. (2) For contaminated human IgG, combined adsorption of ET and IgG in the presence of MOPS of Tris buffer was tested, followed by differential elution using increasing salt concentrations. This attempt was not successful since ET were quantitatively found in the IgG elution fraction. (3) Alternatively, it was proposed to adsorb selectively ET in the presence of acetate buffer (pH 5.0) under non binding conditions for human IgG. Human IgG could then be purified if necessary with the same membrane in the presence of MOPS buffer (pH 6.5). With a 1 m2 histidine-PEVA module under these operating conditions, it is estimated that the depyrogenation of 3 l of 1 mg/ml IgG (human or murine) solution containing 80 EU/ml of ET should be possible.

  12. An Engineering Evaluation of Spherical Resorcinol Formaldehyde Resin

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Birdwell Jr, Joseph F; Lee, Denise L; Taylor, Paul Allen

    2010-09-01

    A small column ion exchange (SCIX) system has been proposed for removal of cesium from caustic, supernatant, and dissolved salt solutions stored or generated from high-level tank wastes at the US Department of Energy (DOE) Hanford Site and Savannah River Sites. In both instances, deployment of SCIX systems, either in-tank or near-tank, is a means of expediting waste pretreatment and dispositioning with minimal or no new infrastructure requirements. Conceptually, the treatment approach can utilize a range of ion exchange media. Previously, both crystalline silicotitanate (CST), an inorganic, nonelutable sorbent, and resorcinol-formaldehyde (RF), an organic, elutable resin, have been considered formore » cesium removal from tank waste. More recently, Pacific Northwest National Laboratory (PNNL) evaluated use of SuperLig{reg_sign} 644, an elutable ion exchange medium, for the subject application. Results of testing indicate hydraulic limitations of the SuperLig{reg_sign} resin, specifically a high pressure drop through packed ion exchange columns. This limitation is likely the result of swelling and shrinkage of the irregularly shaped (granular) resin during repeated conversions between sodium and hydrogen forms as the resin is first loaded then eluted. It is anticipated that a similar flow limitation would exist in columns packed with conventional, granular RF resin. However, use of spherical RF resin is a likely means of mitigating processing limitations due to excessive pressure drop. Although size changes occur as the spherical resin is cycled through loading and elution operations, the geometry of the resin is expected to effectively mitigate the close packing that leads to high pressure drops across ion exchange columns. Multiple evaluations have been performed to determine the feasibility of using spherical RF resin and to obtain data necessary for design of an SCIX process. The work performed consisted of examination of radiation effects on resin performance, quantification of cesium adsorption performance as a function of operating temperature and pH, and evaluation of sodium uptake (titration) as function of pH and counteranion concentration. The results of these efforts are presented in this report. Hydraulic performance of the resin and the use of eluant alternatives to nitric acid have also been evaluated and have been reported elsewhere (Taylor 2009, Taylor and Johnson 2009).« less

  13. Corrosive effects of fluoride on titanium under artificial biofilm.

    PubMed

    Fukushima, Azusa; Mayanagi, Gen; Sasaki, Keiichi; Takahashi, Nobuhiro

    2018-01-01

    This study aimed to investigate the effect of sodium fluoride (NaF) on titanium corrosion using a biofilm model, taking environmental pH into account. Streptococcus mutans cells were used as the artificial biofilm, and pH at the bacteria-titanium interface was monitored after the addition of 1% glucose with NaF (0, 225 or 900ppmF) at 37°C for 90min. In an immersion test, the titanium samples were immersed in the NaF solution (0, 225 or 900ppm F; pH 4.2 or 6.5) for 30 or 90min. Before and after pH monitoring or immersion test, the electrochemical properties of the titanium surface were measured using a potentiostat. The amount of titanium eluted into the biofilm or the immersion solution was measured using inductively coupled plasma mass spectrometry. The color difference (ΔE*ab) and gloss of the titanium surface were determined using a spectrophotometer. After incubation with biofilm, pH was maintained at around 6.5 in the presence of NaF. There was no significant change in titanium surface and elution, regardless of the concentration of NaF. After immersion in 900ppm NaF solution at pH 4.2, corrosive electrochemical change was induced on the surface, titanium elution and ΔE*ab were increased, and gloss was decreased. NaF induces titanium corrosion in acidic environment in vitro, while NaF does not induce titanium corrosion under the biofilm because fluoride inhibits bacterial acid production. Neutral pH fluoridated agents may still be used to protect the remaining teeth, even when titanium-based prostheses are worn. Copyright © 2017 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  14. Secretory immunoglobulin purification from whey by chromatographic techniques.

    PubMed

    Matlschweiger, Alexander; Engelmaier, Hannah; Himmler, Gottfried; Hahn, Rainer

    2017-08-15

    Secretory immunoglobulins (SIg) are a major fraction of the mucosal immune system and represent potential drug candidates. So far, platform technologies for their purification do not exist. SIg from animal whey was used as a model to develop a simple, efficient and potentially generic chromatographic purification process. Several chromatographic stationary phases were tested. A combination of two anion-exchange steps resulted in the highest purity. The key step was the use of a small-porous anion exchanger operated in flow-through mode. Diffusion of SIg into the resin particles was significantly hindered, while the main impurities, IgG and serum albumin, were bound. In this step, initial purity was increased from 66% to 89% with a step yield of 88%. In a second anion-exchange step using giga-porous material, SIg was captured and purified by step or linear gradient elution to obtain fractions with purities >95%. For the step gradient elution step yield of highly pure SIg was 54%. Elution of SIgA and SIgM with a linear gradient resulted in a step yield of 56% and 35%, respectively. Overall yields for both anion exchange steps were 43% for the combination of flow-through and step elution mode. Combination of flow-through and linear gradient elution mode resulted in a yield of 44% for SIgA and 39% for SIgM. The proposed process allows the purification of biologically active SIg from animal whey in preparative scale. For future applications, the process can easily be adopted for purification of recombinant secretory immunoglobulin species. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Optimization of Immobilized Gallium (III) Ion Affinity Chromatography for Selective Binding and Recovery of Phosphopeptides from Protein Digests

    PubMed Central

    Aryal, Uma K.; Olson, Douglas J.H.; Ross, Andrew R.S.

    2008-01-01

    Although widely used in proteomics research for the selective enrichment of phosphopeptides from protein digests, immobilized metal-ion affinity chromatography (IMAC) often suffers from low specificity and differential recovery of peptides carrying different numbers of phosphate groups. By systematically evaluating and optimizing different loading, washing, and elution conditions, we have developed an efficient and highly selective procedure for the enrichment of phosphopeptides using a commercially available gallium(III)-IMAC column (PhosphoProfile, Sigma). Phosphopeptide enrichment using the reagents supplied with the column is incomplete and biased toward the recovery and/or detection of smaller, singly phosphorylated peptides. In contrast, elution with base (0.4 M ammonium hydroxide) gives efficient and balanced recovery of both singly and multiply phosphorylated peptides, while loading peptides in a strong acidic solution (1% trifluoracetic acid) further increases selectivity toward phosphopeptides, with minimal carryover of nonphosphorylated peptides. 2,5-Dihydroxybenzoic acid, a matrix commonly used when analyzing phosphopeptides by matrix-assisted laser desorption/ionization mass spectrometry was also evaluated as an additive in loading and eluting solvents. Elution with 50% acetonitrile containing 20 mg/mL dihydroxybenzoic acid and 1% phosphoric acid gave results similar to those obtained using ammonium hydroxide as the eluent, although the latter showed the highest specificity for phosphorylated peptides. PMID:19183793

  16. DETECTION BY PCR OF HUMAN ENTERIC VIRUSES CONCENTRATED FROM LARGE VOLUMES OF WATER

    EPA Science Inventory

    Viruses are recovered and concentrated from water by passage through a positively charged cartridge filter. Following virus elution from the cartridge filter with beef extract and concentration of the beef extract solution, viruses are usually assayed by cell culture. However...

  17. Determination of 99Tc in fresh water using TRU resin by ICP-MS.

    PubMed

    Guérin, Nicolas; Riopel, Remi; Kramer-Tremblay, Sheila; de Silva, Nimal; Cornett, Jack; Dai, Xiongxin

    2017-10-02

    Technetium-99 ( 99 Tc) determination at trace level by inductively coupled plasma mass spectrometry (ICP-MS) is challenging because there is no readily available appropriate Tc isotopic tracer. A new method using Re as a recovery tracer to determine 99 Tc in fresh water samples, which does not require any evaporation step, was developed. Tc(VII) and Re(VII) were pre-concentrated on a small anion exchange resin (AER) cartridge from one litre of water sample. They were then efficiently eluted from the AER using a potassium permanganate (KMnO 4 ) solution. After the reduction of KMnO 4 in 2 M sulfuric acid solution, the sample was passed through a small TRU resin cartridge. Tc(VII) and Re(VII) retained on the TRU resin were eluted using near boiling water, which can be directly used for the ICP-MS measurement. The results for method optimisation, validation and application were reported. Crown Copyright © 2017. Published by Elsevier B.V. All rights reserved.

  18. Insights in understanding aggregate formation and dissociation in cation exchange chromatography for a structurally unstable Fc-fusion protein.

    PubMed

    Chen, Zhiqiang; Huang, Chao; Chennamsetty, Naresh; Xu, Xuankuo; Li, Zheng Jian

    2016-08-19

    Cation-exchange chromatography (CEX) of a structurally unstable Fc-fusion protein exhibited multi-peak elution profile upon a salt-step elution due to protein aggregation during intra-column buffer transition where low pH and high salt coexisted. The protein exhibited a single-peak elution behavior during a pH-step elution; nevertheless, the levels of soluble aggregates (i.e. high molecular weight species, HMW) in the CEX eluate were still found up to 12-fold higher than that for the load material. The amount of the aggregates formed upon the pH-step elution was dependent on column loading with maximum HMW achieved at intermediate loading levels, supporting the hypothesis that the aggregation was the result of both the conformational changes of the bound protein and the solution concentration of the aggregation-susceptible proteins during elution. Factors such as high load pH, short protein/resin contact time, hydrophilic resin surface, and weak ionizable ligand were effective, to some extent, to reduce aggregate formation by improving the structural integrity of the bound protein. An orthogonal technique, differential scanning fluorimetry (DSF) using Sypro Orange dye confirmed that the bound protein exposed more hydrophobic area than the native molecule in free solution, especially in the pH 4-5 range. The Sypro Orange dye study of resin surface property also demonstrated that the poly[styrene-divinylbenzene]-based Poros XS with polyhydroxyl surface coating is more hydrophobic compared to the agarose-based CM Sepharose FF and SP Sepharose FF. The hydrophobic property of Poros XS contributed to stronger interactions with the partially unfolded bound protein and consequently to the higher aggregate levels seen in Poros XS eluate. This work also investigates the aggregation reversibility in CEX eluate where up to 66% of the aggregates were observed to dissociate into native monomers over a period of 120h, and links the aggregate stability to such conditions as resin surface properties and charged ligand type. Experimental data was correlated semi-quantitatively with theoretical protein charge and hydrophobicity calculations using homology modeling within the BIOVIA Discovery Studio software. Finally, an arginine-sulphopropyl (Arg-SP) agarose resin immobilized with multi-functional ligands was prepared to verify the proposed hypothesis and to eliminate the aggregate formation. The findings of this work provide general insights in understanding aggregate formation and dissociation for structurally unstable proteins in the CEX step. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Application of Snyder-Dolan classification scheme to the selection of "orthogonal" columns for fast screening of illicit drugs and impurity profiling of pharmaceuticals--I. Isocratic elution.

    PubMed

    Fan, Wenzhe; Zhang, Yu; Carr, Peter W; Rutan, Sarah C; Dumarey, Melanie; Schellinger, Adam P; Pritts, Wayne

    2009-09-18

    Fourteen judiciously selected reversed phase columns were tested with 18 cationic drug solutes under the isocratic elution conditions advised in the Snyder-Dolan (S-D) hydrophobic subtraction method of column classification. The standard errors (S.E.) of the least squares regressions of logk' vs. logk'(REF) were obtained for a given column against a reference column and used to compare and classify columns based on their selectivity. The results are consistent with those obtained with a study of the 16 test solutes recommended by Snyder and Dolan. To the extent these drugs are representative, these results show that the S-D classification scheme is also generally applicable to pharmaceuticals under isocratic conditions. That is, those columns judged to be similar based on the 16 S-D solutes were similar based on the 18 drugs; furthermore those columns judged to have significantly different selectivities based on the 16 S-D probes appeared to be quite different for the drugs as well. Given that the S-D method has been used to classify more than 400 different types of reversed phases the extension to cationic drugs is a significant finding.

  20. Separation of copper, iron, and zinc from complex aqueous solutions for isotopic measurement

    USGS Publications Warehouse

    Borrok, D.M.; Wanty, R.B.; Ridley, W.I.; Wolf, R.; Lamothe, P.J.; Adams, M.

    2007-01-01

    The measurement of Cu, Fe, and Zn isotopes in natural samples may provide valuable information about biogeochemical processes in the environment. However, the widespread application of stable Cu, Fe, and Zn isotope chemistry to natural water systems remains limited by our ability to efficiently separate these trace elements from the greater concentrations of matrix elements. In this study, we present a new method for the isolation of Cu, Fe, and Zn from complex aqueous solutions using a single anion-exchange column with hydrochloric acid media. Using this method we are able to quantitatively separate Cu, Fe, and Zn from each other and from matrix elements in a single column elution. Elution of the elements of interest, as well as all other elements, through the anion-exchange column is a function of the speciation of each element in the various concentrations of HCl. We highlight the column chemistry by comparing our observations with published studies that have investigated the speciation of Cu, Fe, and Zn in chloride solutions. The functionality of the column procedure was tested by measuring Cu, Fe, and Zn isotopes in a variety of stream water samples impacted by acid mine drainage. The accuracy and precision of Zn isotopic measurements was tested by doping Zn-free stream water with the Zn isotopic standard. The reproducibility of the entire column separation process and the overall precision of the isotopic measurements were also evaluated. The isotopic results demonstrate that the Cu, Fe, and Zn column separates from the tested stream waters are of sufficient purity to be analyzed directly using a multicollector inductively coupled plasma mass spectrometer (MC-ICP-MS), and that the measurements are fully-reproducible, accurate, and precise. Although limited in scope, these isotopic measurements reveal significant variations in ??65Cu (- 1.41 to + 0.30???), ??56Fe (- 0.56 to + 0.34???), and ??66Zn (0.31 to 0.49???) among samples collected from different abandoned mines within a single watershed. Hence, Cu, Fe, and Zn isotopic measurements may be a powerful tool for fingerprinting specific metal sources and/or examining biogeochemical reactions within fresh water systems.

  1. Recovery of ammonia from domestic wastewater effluents as liquid fertilizers by integration of natural zeolites and hollow fibre membrane contactors.

    PubMed

    Sancho, I; Licon, E; Valderrama, C; de Arespacochaga, N; López-Palau, S; Cortina, J L

    2017-04-15

    The integration of up-concentration processes to increase the efficiency of primary sedimentation, as a solution to achieve energy neutral wastewater treatment plants, requires further post-treatment due to the missing ammonium removal stage. This study evaluated the use of zeolites as a post-treatment step, an alternative to the biological removal process. A natural granular clinoptilolite zeolite was evaluated as a sorbent media to remove low levels (up to 100mg-N/L) of ammonium from treated wastewater using batch and fixed bed columns. After being activated to the Na-form (Z-Na), the granular zeolite shown an ammonium exchange capacity of 29±0.8mgN-NH 4 + /g in single ammonium solutions and 23±0.8mgN-NH 4 + /g in treated wastewater simulating up-concentration effluent at pH=8. The equilibrium removal data were well described by the Langmuir isotherm. The ammonium adsorption into zeolites is a very fast process when compared with polymeric materials (zeolite particle diffusion coefficient around 3×10 -12 m 2 /s). Column experiments with solutions containing 100mgN-NH 4 + /L provide effective sorption and elution rates with concentration factors between 20 and 30 in consecutive operation cycles. The loaded zeolite was regenerated using 2g NaOH/L solution and the rich ammonium/ammonia concentrates 2-3g/L in NaOH were used in a liquid-liquid membrane contactor system in a closed-loop configuration with nitric and phosphoric acid as stripping solutions. The ammonia recovery ratio exceeded 98%. Ammonia nitrate and di-ammonium phosphate concentrated solutions reached up to 2-5% wt. of N. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Chromatographic extraction with di(2-ethylhexyl)orthophosphoric acid for production and purification of promethium-147

    DOEpatents

    Boll, Rose A [Knoxville, TN; Mirzadeh, Saed [Knoxville, TN

    2008-10-14

    A method of producing and purifying promethium-147 including the steps of: irradiating a target material including neodymium-146 with neutrons to produce promethium-147 within the irradiated target material; dissolving the irradiated target material to form an acidic solution; loading the acidic solution onto a chromatographic separation apparatus containing HDEHP; and eluting the apparatus to chromatographically separate the promethium-147 from the neodymium-146.

  3. [The bioresorbable coronary stent: a revolution].

    PubMed

    Koegler, Flora; De Benedetti, Edoardo

    2013-04-10

    Coronary angioplasty has undergone several technological revolutions: starting with balloon angioplasty, then with bare metal stent and finally with drug eluting stent (DES), this technique is now mature. However, once we thought the problem of instent restenosis solved with DES, new concerns arise with late and very late stent thrombosis. Should we therefore proscribe DES? How long should be the duration of dual antiplatelet therapy? And how should we manage the patients who need a surgery and are at high risk of bleeding? Are bioresorbable stents the final solution with their initial mechanical properties, then with their drug eluting effect against intra-stent restenosis, and finally with their complete resorption which leaves the artery free of any foreign material?

  4. Liquid-chromatographic determination of cephalosporins and chloramphenicol in serum.

    PubMed

    Danzer, L A

    1983-05-01

    A "high-performance" liquid-chromatographic technique involving a radial compression module is used for measuring chloramphenicol and five cephalosporin antibiotics: cefotaxime, cefoxitin, cephapirin, and cefamandol. Serum proteins are precipitated with acetonitrile solution containing 4'-nitroacetanilide as the internal standard. The drugs are eluted with a mobile phase of methanol/acetate buffer (30/70 by vol), pH 5.5. Absorbance of the cephalosporins is monitored at 254 nm. Standard curves are linear to at least 100 mg/L. The absorbance of chloramphenicol is monitored at 254 nm and 280 nm, and its standard curve is linear to at least 50 mg/L. The elution times for various other drugs were also determined, to check for potential interferents.

  5. Fast and Cost-Effective Biochemical Spectrophotometric Analysis of Solution of Insect "Blood" and Body Surface Elution.

    PubMed

    Łoś, Aleksandra; Strachecka, Aneta

    2018-05-09

    Using insect hemolymph ("blood") and insect body surface elutions, researchers can perform rapid and cheap biochemical analyses to determine the insect's immunology status. The authors of this publication describe a detailed methodology for a quick marking of the concentration of total proteins and evaluation of the proteolytic system activity (acid, neutral, and alkaline proteases and protease inhibitors), as well as a methodology for quick "liver" tests in insects: alanine aminotransferase (ALT), aspartate aminotransferase (AST), alkaline phosphatase (ALP), and urea and glucose concentration analyses. The meaning and examples of an interpretation of the results of the presented methodology for biochemical parameter determination are described for the example of honey bees.

  6. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schmehl, Joerg, E-mail: joerg.schmehl@med.uni-tuebingen.de; Ruhr, Juergen von der; Dobratz, Markus

    Purpose. The efficacy of drug-eluting balloons has been demonstrated in clinical trials. The drug predominantly used is paclitaxel because of its lipophilic properties and the rapid onset of action. The aim of the investigation was to evaluate the feasibility and efficacy of an alternative balloon coating with rapamycin that can be applied on site.MethodsThe balloon coating (3.0/18 and 3.0/12 mm, Cathy No. 4, Translumina GmbH) with rapamycin was conducted with a coating machine (Translumina GmbH). Concentrations were 2, 2 Multiplication-Sign 2, 3, and 4 %. Measurements regarding the amount of substance released to the vessel wall were carried out onmore » explanted porcine coronaries by means of ultraviolet and visible-light spectroscopy. Inflation time varied between 30 and 120 s. The biological effect of the coating was evaluated in a porcine peripheral overstretch and stent implantation model. Results. The amount of rapamycin on the balloon surface ranged from 558 {+-} 108 {mu}g for the 2 % solution to 1,441 {+-} 228 {mu}g in the 4 % solution. An amount of 95 {+-} 63-193 {+-} 113 {mu}g was released into the vessel wall. The quantitative measurements of the angiographic examinations 4 weeks after treatment revealed a reduction of diameter stenosis from 20.6 {+-} 17.4 % in the control group to 11.6 {+-} 5.5 % in the drug-eluting balloon group. Conclusion. A balloon coating with rapamycin omitting an excipient is possible with a dose-adjustable coating machine. However, the biological effects are moderate, which make further optimization of the coating process and evaluation of appropriate excipients necessary.« less

  7. ANALYSIS OF ELECTROLESS NICKEL SOLUTIONS BY ANION CHROMATOGRAPHY

    EPA Science Inventory

    The principal appeal of ion chromatography (IC) as analytical technique lies in the ability to rapidly analyze a mixture of ions of widely varying concentrations and properties in a single elution. It is therefore not surprising that IC has been hampered by the similar ion exchan...

  8. Elution of uranium and transition metals from amidoxime-based polymer adsorbents for sequestering uranium from seawater

    DOE PAGES

    Pan, Horng-Bin; Kuo, Li-Jung; Miyamoto, Naomi; ...

    2015-11-30

    High-surface-area amidoxime and carboxylic acid grafted polymer adsorbents developed at Oak Ridge National Laboratory were tested for sequestering uranium in a flowing seawater flume system at the PNNL-Marine Sciences Laboratory. FTIR spectra indicate that a KOH conditioning process is necessary to remove the proton from the carboxylic acid and make the sorbent effective for sequestering uranium from seawater. The alkaline conditioning process also converts the amidoxime groups to carboxylate groups in the adsorbent. Both Na 2CO 3 H 2O 2 and hydrochloric acid elution methods can remove ~95% of the uranium sequestered by the adsorbent after 42 days of exposuremore » in real seawater. The Na 2CO 3 H 2O 2 elution method is more selective for uranium than conventional acid elution. Iron and vanadium are the two major transition metals competing with uranium for adsorption to the amidoxime-based adsorbents in real seawater. Tiron (4,5-Dihydroxy-1,3-benzenedisulfonic acid disodium salt, 1 M) can remove iron from the adsorbent very effectively at pH around 7. The coordination between vanadium (V) and amidoxime is also discussed based on our 51V NMR data.« less

  9. RECOVERY OF ALUMINUM FROM FISSION PRODUCTS

    DOEpatents

    Blanco, R.E.; Higgins, I.R.

    1962-11-20

    A method is given for recovertng aluminum values from aqueous solutions containing said values together with fission products. A mixture of Fe/sub 2/O/ sub 3/ and MnO/sub 2/ is added to a solution containing aluminum and fission products. The resulting aluminum-containing supernatant is then separated from the fission product-bearing metal oxide precipitate and is contacted with a cation exchange resin. The aluminum sorbed on the resin is then eluted and recovered. (AEC)

  10. Fast "hyperlayer" separation development in sedimentation field flow fractionation.

    PubMed

    Kassab, James R; Cardot, Philippe J P; Zahoransky, Richard A; Battu, Serge

    2005-11-05

    Specific prototypes of sedimentation field flow fractionation devices (SdFFF) have been developed with relative success for cell sorting. However, no data are available to compare these apparatus with commercial ones. In order to compare with other devices mainly used for non-biological species, biocompatible systems were used for standard particle (latex: 3-10 microm of different size dispersities) separation development. In order to enhance size dependent separations, channels of reduced thickness were used (80 and 100 microm) and channel/carrier-phase equilibration procedures were necessary. For sample injection, the use of inlet tubing linked to the FFF accumulation wall, common for cell sorting, can be extended to latex species when they are eluted in the Steric Hyperlayer elution mode. It avoids any primary relaxation steps (stop flow injection procedure) simplifying series of elution processing. Mixtures composed of four different monodispersed latex beads can be eluted in 6 min with 100 microm channel thickness.

  11. Ultrasound-assisted leaching of rare earths from the weathered crust elution-deposited ore using magnesium sulfate without ammonia-nitrogen pollution.

    PubMed

    Yin, Shaohua; Pei, Jiannan; Jiang, Feng; Li, Shiwei; Peng, Jinhui; Zhang, Libo; Ju, Shaohua; Srinivasakannan, Chandrasekar

    2018-03-01

    The in situ leaching process of China's unique ion-adsorption rare earth ores has caused severe environmental damages due to the use of (NH 4 ) 2 SO 4 solution. This study reports that magnesium sulfate (MgSO 4 ) as a leaching agent would replace (NH 4 ) 2 SO 4 by ultrasonically assisted leaching to deal with the ammonia-nitrogen pollution problem and enhance leaching process. At leaching conditions of 3wt% MgSO 4 concentration, 3:1L/S ratio and 30min, the total rare earth leaching efficiency reaches 75.5%. Ultrasound-assisted leaching experiments show that the leaching efficiency of rare earths is substantially increased by introducing ultrasound, and nearly completely leached out after two stage leaching process. Thus, ultrasonic-assisted leaching process with MgSO 4 is not only effective but also environmentally friendly, and beneficial to leach rare earths at laboratory scale. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Residual HEMA and TEGDMA Release and Cytotoxicity Evaluation of Resin-Modified Glass Ionomer Cement and Compomers Cured with Different Light Sources

    PubMed Central

    Botsali, Murat Selim; Kuşgöz, Adem; Altintaş, Subutay Han; Ülker, Hayriye Esra; Kiliç, Serdar; Başak, Feridun; Ülker, Mustafa

    2014-01-01

    The purpose of this study was first to evaluate the elution of 2-hydroxyethyl methacrylate (HEMA) and triethylene glycol dimethacrylate (TEGDMA) monomers from resin-modified glass ionomer cement (RMGIC) and compomers cured with halogen and light-emitting diode (LED) light-curing units (LCUs). The effect of cured materials on the viability of L929 fibroblast cells was also evaluated. One RMGIC (Ketac N100) and two compomers (Dyract Extra and Twinkystar) were tested. Materials were prepared in teflon disks and light-cured with LED or halogen LCUs. The residual monomers of resin materials in solution were identified using high-performance liquid chromatography. The fibroblast cells' viability was analyzed using MTT assay. The type of LCU did not have a significant effect on the elution of HEMA and TEGDMA. A greater amount of HEMA than TEGMDA was eluted. The amount of TEGDMA eluted from Twinkystar was greater than Dyract Extra (P < 0.05) when cured with a halogen LCU. All material-LCU combinations decreased the fibroblast cells' viability more than the control group (P < 0.01), except for Dyract Extra cured with a halogen LCU (P > 0.05). Curing with the LED LCU decreased the cells' viability more than curing with the halogen LCU for compomers. For Ketac N100, the halogen LCU decreased the cells' viability more than the LED LCU. PMID:24592149

  13. Fibrinogen species as resolved by HPLC-SAXS data processing within the UltraScan Solution Modeler (US-SOMO) enhanced SAS module.

    PubMed

    Brookes, Emre; Pérez, Javier; Cardinali, Barbara; Profumo, Aldo; Vachette, Patrice; Rocco, Mattia

    2013-12-01

    Fibrinogen is a large heterogeneous aggregation/degradation-prone protein playing a central role in blood coagulation and associated pathologies, whose structure is not completely resolved. When a high-molecular-weight fraction was analyzed by size-exclusion high-performance liquid chromatography/small-angle X-ray scattering (HPLC-SAXS), several composite peaks were apparent and because of the stickiness of fibrinogen the analysis was complicated by severe capillary fouling. Novel SAS analysis tools developed as a part of the UltraScan Solution Modeler ( US-SOMO ; http://somo.uthscsa.edu/), an open-source suite of utilities with advanced graphical user interfaces whose initial goal was the hydrodynamic modeling of biomacromolecules, were implemented and applied to this problem. They include the correction of baseline drift due to the accumulation of material on the SAXS capillary walls, and the Gaussian decomposition of non-baseline-resolved HPLC-SAXS elution peaks. It was thus possible to resolve at least two species co-eluting under the fibrinogen main monomer peak, probably resulting from in-column degradation, and two others under an oligomers peak. The overall and cross-sectional radii of gyration, molecular mass and mass/length ratio of all species were determined using the manual or semi-automated procedures available within the US-SOMO SAS module. Differences between monomeric species and linear and sideways oligomers were thus identified and rationalized. This new US-SOMO version additionally contains several computational and graphical tools, implementing functionalities such as the mapping of residues contributing to particular regions of P ( r ), and an advanced module for the comparison of primary I ( q ) versus q data with model curves computed from atomic level structures or bead models. It should be of great help in multi-resolution studies involving hydrodynamics, solution scattering and crystallographic/NMR data.

  14. Microchip electrospray: improvements in spray and signal stability during gradient elution by an inverted postcolumn makeup flow.

    PubMed

    Jung, Stephanie; Effelsberg, Uwe; Tallarek, Ulrich

    2011-12-01

    Dynamic changes in mobile phase composition during high-performance liquid chromatography (HPLC) gradient elution coupled to mass spectrometry (MS) sensitively affect electrospray modes. We investigate the impact of the eluent composition on spray stability and MS response by infusion and injection experiments with a small tetrapeptide in water-acetonitrile mixtures. The employed HPLC/electrospray (ESI)-MS configuration uses a microchip equipped with an enrichment column, a separation column, and a makeup flow (MUF) channel. One nano pump is connected to the separation column, while a second one delivers solvent of exactly inverted composition to the MUF channel. Both solvent streams are united behind the separation column, before the ESI tip, such that the resulting electrosprayed solution always has identical composition during a gradient elution. Analyte peak parameters without and with MUF compensation are determined and discussed with respect to the electrospray mode and eluent composition. The postcolumn MUF significantly improves spray and signal stability over the entire solvent gradient, without compromising the performance of the HPLC separation column. It can also be conveniently implemented on microchip platforms.

  15. In vivo performance of a drug-eluting contact lens to treat glaucoma for a month

    PubMed Central

    Ciolino, Joseph B.; Stefanescu, Cristina F.; Ross, Amy E.; Salvador-Culla, Borja; Cortez, Priscila; Ford, Eden M.; Wymbs, Kate A.; Sprague, Sarah L.; Mascoop, Daniel R.; Rudina, Shireen S.; Trauger, Sunia A.; Cade, Fabiano; Kohane, Daniel S.

    2013-01-01

    For nearly half a century, contact lenses have been proposed as a means of ocular drug delivery, but achieving controlled drug release has been a significant challenge. We have developed a drug-eluting contact lens designed for prolonged delivery of latanoprost for the treatment of glaucoma, the leading cause of irreversible blindness worldwide. Latanoprost-eluting contact lenses were created by encapsulating latanoprost–poly(lactic-co-glycolic acid) films in methafilcon by ultraviolet light polymerization. In vitro and in vivo studies showed an early burst of drug release followed by sustained release for one month. Contact lenses containing thicker drug–polymer films demonstrated released a greater amount of drug after the initial burst. In vivo, single contact lenses were able to achieve, for at least one month, latanoprost concentrations in the aqueous humor that were comparable to those achieved with topical latanoprost solution, the current first-line treatment for glaucoma. The lenses appeared safe in cell culture and animal studies. This contact lens design can potentially be used as a treatment for glaucoma and as a platform for other ocular drug delivery applications. PMID:24094935

  16. Method for the analysis of triadimefon and ethofumesate from dislodgeable foliar residues on turfgrass by solid-phase extraction and in-vial elution.

    PubMed

    Runes, H B; Jenkins, J J; Field, J A

    1999-08-01

    Triadimefon, a fungicide, and ethofumesate, an herbicide, are commonly applied to turfgrass in the Pacific Northwest, resulting in foliar residues. A simple and rapid method was developed to determine triadimefon and ethofumesate concentrations from dislodgeable foliar residues on turfgrass. Turfgrass samples were washed, and wash water containing surfactant (a 0.126% solution) was collected for residue analysis. This analytical method utilizes a 25 mm C(8) Empore disk and in-vial elution to quantitatively determine triadimefon and ethofumesate in 170 mL aqueous samples. The analytes were eluted by placing the disk in a 2 mL autosampler vial with 980 microL of ethyl acetate and 20 microL of 2-chlorolepidine, the internal standard, for analysis by GC/MS. The method quantitation limits are 0.29 microg/L for ethofumesate and 0.59 microg/L for triadimefon. The method detection limits are 0.047 microg/L and 0.29 microg/L for ethofumesate and triadimefon, respectively. Concentrations of triadimefon and ethofumesate from dislodgeable foliar residues from a field study are reported.

  17. Comparison between sensitivity of a viscometric method and sensitivity of the alkaline elution assay for the determination of DNA damage induced by dimethylsulfate in vitro.

    PubMed

    Parodi, S; Balbi, C; Taningher, M; Abelmoschi, M L; Pala, M; Parodi, G; Santi, L

    1982-03-01

    DNA damage induced by dimethylsulfate (DMS) was measured with a new oscillating crucible viscometer, having a U-shaped circular channel. Rat liver nuclei were treated in vitro. Viscosity was measured by lysing nuclei in an aklaline lysing solution (pH 12.5; 25 degrees C). Nuclei were lysed immediately in the viscometer and released DNA started to uncoil. In control samples the viscosity increased very slowly with time, reaching a maximum only after about 8 h. A progressively more rapid increase in viscosity was seen with increasing concentrations of DMS. The time of DNA disentanglement was sensitive to about 30 times less breaks than the alkaline elution assay.

  18. [Determination of six main components in compound theophylline tablet by convolution curve method after prior separation by column partition chromatography

    NASA Technical Reports Server (NTRS)

    Zhang, S. Y.; Wang, G. F.; Wu, Y. T.; Baldwin, K. M. (Principal Investigator)

    1993-01-01

    On a partition chromatographic column in which the support is Kieselguhr and the stationary phase is sulfuric acid solution (2 mol/L), three components of compound theophylline tablet were simultaneously eluted by chloroform and three other components were simultaneously eluted by ammonia-saturated chloroform. The two mixtures were determined by computer-aided convolution curve method separately. The corresponding average recovery and relative standard deviation of the six components were as follows: 101.6, 1.46% for caffeine; 99.7, 0.10% for phenacetin; 100.9, 1.31% for phenobarbitone; 100.2, 0.81% for theophylline; 99.9, 0.81% for theobromine and 100.8, 0.48% for aminopyrine.

  19. Development of a real-world direct interface for integrated DNA extraction and amplification in a microfluidic device.

    PubMed

    Shaw, Kirsty J; Joyce, Domino A; Docker, Peter T; Dyer, Charlotte E; Greenway, Gillian M; Greenman, John; Haswell, Stephen J

    2011-02-07

    Integrated DNA extraction and amplification have been carried out in a microfluidic device using electro-osmotic pumping (EOP) for fluidic control. All the necessary reagents for performing both DNA extraction and polymerase chain reaction (PCR) amplification were pre-loaded into the microfluidic device following encapsulation in agarose gel. Buccal cells were collected using OmniSwabs [Whatman™, UK] and manually added to a chaotropic binding/lysis solution pre-loaded into the microfluidic device. The released DNA was then adsorbed onto a silica monolith contained within the DNA extraction chamber and the microfluidic device sealed using polymer electrodes. The washing and elution steps for DNA extraction were carried out using EOP, resulting in transfer of the eluted DNA into the PCR chamber. Thermal cycling, achieved using a Peltier element, resulted in amplification of the Amelogenin locus as confirmed using conventional capillary gel electrophoresis. It was demonstrated that the PCR reagents could be stored in the microfluidic device for at least 8 weeks at 4 °C with no significant loss of activity. Such methodology lends itself to the production of 'ready-to-use' microfluidic devices containing all the necessary reagents for sample processing, with many obvious applications in forensics and clinical medicine.

  20. Analysis of isothiazolinone biocides in paper for food packaging by ultra-high-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Lin, Q-B; Wang, T-J; Song, H; Li, B

    2010-12-01

    A novel and simple method to detect isothiazolinone-type biocides (2-methyl-3-isothiazolinone (MI), 5-chloro-2-methyl-3-isothiazolinone (CMI), 1,2-benzisothiazolinone (BIT) and 2-octyl-3-isothiazolinone (OIT)) in paper used for food packaging by ultrasonic extraction coupled with UPLC-MS/MS was developed. Parameters affecting process efficiency such as extraction solvents, UPLC mobile phase, gradient elution procedure and MS/MS conditions were studied to optimise the operating conditions. Using the optimised gradient elution procedure, the retention time was less than 6 min. The limits of detection (LODs) were found to be between 0.001 and 0.010 mg kg⁻¹, which was validated using actual concentrations. After diluting the standard solution with a blank matrix, the linear calibration curve ranges were 0.002-1.000 mg kg⁻¹ for BIT and OIT, 0.005-1.000 mg kg⁻¹ for MI, and 0.020-1.000 mg kg⁻¹ for CMI, with correlation coefficients higher than 0.9985 (n = 6). A good level of precision with a mean recovery greater than 81.3% and a relative standard deviation (RSD) less than 6.2% were also obtained. A methodology has been proposed for the analysis of isothiazolinones in paper.

  1. Development of Customized [18F]Fluoride Elution Techniques for the Enhancement of Copper-Mediated Late-Stage Radiofluorination

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mossine, Andrew V.; Brooks, Allen F.; Ichiishi, Naoko

    In a relatively short period of time, transition metal-mediated radiofluorination reactions have changed the PET radiochemistry landscape. These reactions have enabled the radiofluorination of a wide range of substrates, facilitating access to radiopharmaceuticals that were challenging to synthesize using traditional fluorine-18 radiochemistry. However, the process of adapting these new reactions for automated radiopharmaceutical production has revealed limitations in fitting them into the confines of traditional radiochemistry systems. In particular, the presence of bases (e.g. K 2CO 3) and/or phase transfer catalysts (PTC) (e.g. kryptofix 2.2.2) associated with fluorine-18 preparation has been found to be detrimental to reaction yields. We hypothesizedmore » that these limitations could be addressed through the development of alternate techniques for preparing [18F]fluoride. This approach also opens the possibility that an eluent can be individually tailored to meet the specific needs of a metal-catalyzed reaction of interest. In this communication, we demonstrate that various solutions of copper salts, bases, and ancillary ligands can be utilized to elute [ 18F]fluoride from ion exchange cartridges. The new procedures we present here are effective for fluorine-18 radiochemistry and, as proof of concept, have been used to optimize an otherwise base-sensitive copper-mediated radiofluorination reaction.« less

  2. Development of Customized [18F]Fluoride Elution Techniques for the Enhancement of Copper-Mediated Late-Stage Radiofluorination

    DOE PAGES

    Mossine, Andrew V.; Brooks, Allen F.; Ichiishi, Naoko; ...

    2017-03-22

    In a relatively short period of time, transition metal-mediated radiofluorination reactions have changed the PET radiochemistry landscape. These reactions have enabled the radiofluorination of a wide range of substrates, facilitating access to radiopharmaceuticals that were challenging to synthesize using traditional fluorine-18 radiochemistry. However, the process of adapting these new reactions for automated radiopharmaceutical production has revealed limitations in fitting them into the confines of traditional radiochemistry systems. In particular, the presence of bases (e.g. K 2CO 3) and/or phase transfer catalysts (PTC) (e.g. kryptofix 2.2.2) associated with fluorine-18 preparation has been found to be detrimental to reaction yields. We hypothesizedmore » that these limitations could be addressed through the development of alternate techniques for preparing [18F]fluoride. This approach also opens the possibility that an eluent can be individually tailored to meet the specific needs of a metal-catalyzed reaction of interest. In this communication, we demonstrate that various solutions of copper salts, bases, and ancillary ligands can be utilized to elute [ 18F]fluoride from ion exchange cartridges. The new procedures we present here are effective for fluorine-18 radiochemistry and, as proof of concept, have been used to optimize an otherwise base-sensitive copper-mediated radiofluorination reaction.« less

  3. Evaluation of in vitro serial antibiotic elution from meropenem-impregnated polymethylmethacrylate beads after ethylene oxide gas and autoclave sterilization.

    PubMed

    Báez, L A; Langston, C; Givaruangsawat, S; McLaughlin, R

    2011-01-01

    To determine the elution properties of meropenem and to compare the elutions of meropenem-impregnated polymethylmethacrylate (PMMA) beads without sterilization (P-M-C) to those sterilized with steam (P-M-A) and ethylene oxide gas (P-M-EO). A commercial bead mould was used to produce four groups of beads: one group without antibiotic (negative control), and three groups of meropenem-impregnated beads: P-M-C, P-M-A, and P-M-EO. The beads were placed in a phosphate buffered solution and eluent samples were collected. Concentrations of the antibiotic in eluent samples from the two sterilized groups and the control beads were determined using a microbiological assay at 1, 3, 6 and 12 hours and at 1, 2, 3, 6, 9, 12, 15, 18, 22, 26, and 30 days. The microbiological assay resulted in no zone of inhibition at all time periods for the P-M-A samples and the samples of PMMA without antimicrobial. The meropenem concentration on the eluent remained above 4 mcg/ml for 15 days in the P-M-C group and until day 18 for P-M-EO group. There was no statistical difference in AUC0-∞ (p<0.318), however significance did occur for MRT (p<0.005) when comparing P-M-C and P-M-EO with the later being higher. The meropenem incorporated in the PMMA beads eluted effectively and gradually decreased after the 24 hour peak, but remained above the concentration level of 4 mcg/ml for 15 days in the P-M-C group and until day 18 for P-M-EO group. Ethylene oxide does not adversely affect meropenem's elution from PMMA beads.

  4. Numerical modeling of elution peak profiles in supercritical fluid chromatography. Part I--elution of an unretained tracer.

    PubMed

    Kaczmarski, Krzysztof; Poe, Donald P; Guiochon, Georges

    2010-10-15

    When chromatography is carried out with high-density carbon dioxide as the main component of the mobile phase (a method generally known as "supercritical fluid chromatography" or SFC), the required pressure gradient along the column is moderate. However, this mobile phase is highly compressible and, under certain experimental conditions, its density may decrease significantly along the column. Such an expansion absorbs heat, cooling the column, which absorbs heat from the outside. The resulting heat transfer causes the formation of axial and radial gradients of temperature that may become large under certain conditions. Due to these gradients, the mobile phase velocity and most physico-chemical parameters of the system (viscosity, diffusion coefficients, etc.) are no longer constant throughout the column, resulting in a loss of column efficiency, even at low flow rates. At high flow rates and in serious cases, systematic variations of the retention factors and the separation factors with increasing flow rates and important deformations of the elution profiles of all sample components may occur. The model previously used to account satisfactorily for the effects of the viscous friction heating of the mobile phase in HPLC is adapted here to account for the expansion cooling of the mobile phase in SFC and is applied to the modeling of the elution peak profiles of an unretained compound in SFC. The numerical solution of the combined heat and mass balance equations provides temperature and pressure profiles inside the column, and values of the retention time and efficiency for elution of this unretained compound that are in excellent agreement with independent experimental data. Copyright © 2010 Elsevier B.V. All rights reserved.

  5. Suppression of scarring in peripheral nerve implants by drug elution.

    PubMed

    FitzGerald, James J

    2016-04-01

    Medical implants made of non-biological materials provoke a chronic inflammatory response, resulting in the deposition of a collagenous scar tissue (ST) layer on their surface, that gradually thickens over time. This is a critical problem for neural interfaces. Scar build-up on electrodes results in a progressive decline in signal level because the scar tissue gradually separates axons away from the recording contacts. In regenerative sieves and microchannel electrodes, progressive scar deposition will constrict and may eventually choke off the sieve hole or channel lumen. Interface designs need to address this issue if they are to be fit for long term use. This study examines a novel method of inhibiting the formation and thickening of the fibrous scar. Research to date has mainly focused on methods of preventing stimulation of the foreign body response by implant surface modification. In this paper a pharmacological approach using drug elution to suppress chronic inflammation is introduced. Microchannel implants made of silicone doped with the steroid drug dexamethasone were implanted in the rat sciatic nerve for periods of up to a year. Tissue from within the microchannels was compared to that from control devices that did not release any drug. In the drug eluting implants the scar layer was significantly thinner at all timepoints, and unlike the controls it did not continue to thicken after 6 months. Control implants supported axon regeneration well initially, but axon counts fell rapidly at later timepoints as scar thickened. Axon counts in drug eluting devices were initially much lower, but increased rather than declined and by one year were significantly higher than in controls. Drug elution offers a potential long term solution to the problem of performance degradation due to scarring around neural implants.

  6. Suppression of scarring in peripheral nerve implants by drug elution

    NASA Astrophysics Data System (ADS)

    FitzGerald, James J.

    2016-04-01

    Objective. Medical implants made of non-biological materials provoke a chronic inflammatory response, resulting in the deposition of a collagenous scar tissue (ST) layer on their surface, that gradually thickens over time. This is a critical problem for neural interfaces. Scar build-up on electrodes results in a progressive decline in signal level because the scar tissue gradually separates axons away from the recording contacts. In regenerative sieves and microchannel electrodes, progressive scar deposition will constrict and may eventually choke off the sieve hole or channel lumen. Interface designs need to address this issue if they are to be fit for long term use. This study examines a novel method of inhibiting the formation and thickening of the fibrous scar. Approach. Research to date has mainly focused on methods of preventing stimulation of the foreign body response by implant surface modification. In this paper a pharmacological approach using drug elution to suppress chronic inflammation is introduced. Microchannel implants made of silicone doped with the steroid drug dexamethasone were implanted in the rat sciatic nerve for periods of up to a year. Tissue from within the microchannels was compared to that from control devices that did not release any drug. Main results. In the drug eluting implants the scar layer was significantly thinner at all timepoints, and unlike the controls it did not continue to thicken after 6 months. Control implants supported axon regeneration well initially, but axon counts fell rapidly at later timepoints as scar thickened. Axon counts in drug eluting devices were initially much lower, but increased rather than declined and by one year were significantly higher than in controls. Significance. Drug elution offers a potential long term solution to the problem of performance degradation due to scarring around neural implants.

  7. Fate of process solution cyanide and nitrate at three nevada gold mines inferred from stable carbon and nitrogen isotope measurements

    USGS Publications Warehouse

    Johnson, C.A.; Grimes, D.J.; Rye, R.O.

    2000-01-01

    Stable isotope methods have been used to identify the mechanisms responsible for cyanide consumption at three heap-leach operations that process Carlin-type gold ores in Nevada, U.S.A. The reagent cyanide had ??15N values ranging from -5 to -2??? and ??13C values from -60 to -35???. The wide ??13C range reflects the use by different suppliers of isotopically distinct natural-gas feedstocks and indicates that isotopes may be useful in environmental studies where there is a need to trace cyanide sources. In heap-leach circuits displaying from 5 to 98% consumption of cyanide, barren-solution and pregnant-solution cyanide were isotopically indistinguishable. The similarity is inconsistent with cyanide loss predominantly by HCN offgassing (a process that in laboratory experiments caused substantial isotopic changes), but it is consistent with cyanide retention within the heaps as solids, a process that caused minimal isotopic changes in laboratory simulations, or with cyanide oxidation, which also appears to cause minimal changes. In many pregnant solutions cyanide was carried entirely as metal complexes, which is consistent with ferrocyanides having precipitated or cyanocomplexes having been adsorbed within the heaps. It is inferred that gaseous cyanide emissions from operations of this type are less important than has generally been thought and that the dissolution or desorption kinetics of solid species is an important control on cyanide elution when the spent heaps undergo rinsing. Nitrate, nitrite and ammonium had ??15N values of 1-16???. The data reflect isotopic fractionation during ammonia offgassing or denitrification of nitrate - particularly in reclaim ponds - but do not indicate the extent to which nitrate is derived from cyanide or from explosive residues. ?? The Institution of Mining and Metallurgy 2000.

  8. A novel method for the determination of synthetic colors in ice cream samples.

    PubMed

    Tripathi, Meenakshi; Khanna, Subhash K; Das, Mukul

    2004-01-01

    A simple method has been developed for the extraction, separation, and determination of synthetic colors in ice cream samples. The process involves the breakdown of emulsion by neutral detergents (Triton X-100 and Tween 20) followed by extraction with petroleum ether for removal of fat. The aqueous colored solution obtained is treated with 5% acetic acid, and the uptake of color is carried out by a wool-dyeing technique. The color is eluted from the wool with 5% ammonia solution, the solution is evaporated to dryness, and the residue is dissolved in 60% ethanol for paper chromatography using trisodium citrate-ammonia-water (2 + 5 + 95, w/v/v) as the mobile phase. The colored spots from the paper chromatogram are cut and eluted with 60% ethanol, and the absorbance is measured at the respective lambda maximum corresponding to the Rf value of the appropriate standard. The recoveries of 6 colors, including sunset yellow FCF (SSYFCF), tartrazine, carmoisine, ponceau 4R, brilliant blue FCF (BBFCF), and fast green FCF from spiked samples with either detergent were found to be >90%. However, recoveries of erythrosine were 21 and 65% with Triton X-100 and Tween 20, respectively. Indigo carmine could not be recovered at all because of its fugitive property in 5% ammonia solution, which is used to strip the color from the wool. The sensitivity of the method with the use of Tween 20 is 1 ppm (1 microg/g) for the colors in spiked ice cream samples. With this method, we analyzed samples of 20 branded colored ice cream. The results showed the presence of tartrazine (8.4-43.3 ppm), SSYFCF (23.5-117.6 ppm), carmoisine (traces-53.2 ppm), erythrosine (3.5 ppm), and BBFCF (4.1 ppm) in the ice cream samples. Apart from 2 samples of tuttifruity, all of the ice cream samples showed the presence of permitted synthetic colors below the permissible level of 100 ppm established by the Prevention of Food Adulteration Act of India.

  9. Method for dissolving plutonium oxide with HI and separating plutonium

    DOEpatents

    Vondra, Benedict L.; Tallent, Othar K.; Mailen, James C.

    1979-01-01

    PuO.sub.2 -containing solids, particularly residues from incomplete HNO.sub.3 dissolution of irradiated nuclear fuels, are dissolved in aqueous HI. The resulting solution is evaporated to dryness and the solids are dissolved in HNO.sub.3 for further chemical reprocessing. Alternatively, the HI solution containing dissolved Pu values, can be contacted with a cation exchange resin causing the Pu values to load the resin. The Pu values are selectively eluted from the resin with more concentrated HI.

  10. Tungsten-188/carrier-free rhenium-188 perrhenic acid generator system

    DOEpatents

    Knapp, Jr., Furn F.; Lisic, Edward C.; Mirzadeh, Saed; Callahan, Alvin P.

    1993-01-01

    A generator system for providing a carrier-free radioisotope in the form of an acid comprises a chromatography column in tandem fluid connection with an ion exchange column, the chromatography column containing a charge of a radioactive parent isotope. The chromatography column, charged with a parent isotope, is eluted with an alkali metal salt solution to generate the radioisotope in the form of an intermediate solution, which is passed through the ion-exchange column to convert the radioisotope to a carrier-free acid form.

  11. Tungsten-188/carrier-free rhenium-188 perrhenic acid generator system

    DOEpatents

    Knapp, F.F. Jr.; Lisic, E.C.; Mirzadeh, S.; Callahan, A.P.

    1993-02-16

    A generator system for providing a carrier-free radioisotope in the form of an acid comprises a chromatography column in tandem fluid connection with an ion exchange column, the chromatography column containing a charge of a radioactive parent isotope. The chromatography column, charged with a parent isotope, is eluted with an alkali metal salt solution to generate the radioisotope in the form of an intermediate solution, which is passed through the ion-exchange column to convert the radioisotope to a carrier-free acid form.

  12. Tungsten-188/carrier-free rhenium-188 perrhenic acid generator system

    DOEpatents

    Knapp, Jr., Furn F.; Lisic, Edward C.; Mirzadeh, Saed; Callahan, Alvin P.

    1994-01-01

    A generator system for providing a carrier-free radioisotope in the form of an acid comprises a chromatography column in tandem fluid connection with an ion exchange column, the chromatography column containing a charge of a radioactive parent isotope. The chromatography column, charged with a parent isotope, is eluted with an alkali metal salt solution to generate the radioisotope in the form of an intermediate solution, which is passed through the ion-exchange column to convert the radioisotope to a carrier-free acid form.

  13. Application of Snyder-Dolan Classification Scheme to the Selection of “Orthogonal” Columns for Fast Screening for Illicit Drugs and Impurity Profiling of Pharmaceuticals - I. Isocratic Elution

    PubMed Central

    Fan, Wenzhe; Zhang, Yu; Carr, Peter W.; Rutan, Sarah C.; Dumarey, Melanie; Schellinger, Adam P.; Pritts, Wayne

    2011-01-01

    Fourteen judiciously selected reversed-phase columns were tested with 18 cationic drug solutes under the isocratic elution conditions advised in the Snyder-Dolan (S-D) hydrophobic subtraction method of column classification. The standard errors (S.E.) of the least squares regressions of log k′ vs. log k′REF were obtained for a given column against a reference column and used to compare and classify columns based on their selectivity. The results are consistent with those obtained with a study of the 16 test solutes recommended by Snyder and Dolan. To the extent that these drugs are representative these results show that the S-D classification scheme is also generally applicable to pharmaceuticals under isocratic conditions. That is, those columns judged to be similar based on the S-D 16 solutes were similar based on the 18 drugs; furthermore those columns judged to have significantly different selectivities based on the 16 S-D probes appeared to be quite different for the drugs as well. Given that the S-D method has been used to classify more than 400 different types of reversed phases the extension to cationic drugs is a significant finding. PMID:19698948

  14. Determination of picomole quantities of acetylcholine and choline in physiologic salt solutions.

    PubMed

    Gilberstadt, M L; Russell, J A

    1984-04-01

    An assay capable of detecting tens-of-picomole quantities of choline and acetylcholine in milliliter volumes of a physiological salt solution has been developed. Silica column chromatography was used to bind and separate 10-3000 pmol [14C]choline and [14C]acetylcholine standards made up in 3 ml of a bicarbonate-buffered Krebs-Ringer solution. The silica columns bound 95-98% of both choline and acetylcholine. Of the bound choline 84-87% was eluted in 1.5 ml of 0.075 N HCl, whereas 95-98% of the bound acetylcholine was eluted in a subsequent wash with 1.5 ml of 0.030 N HCl in 10% 2-butanone. Vacuum centrifugation of the eluants yielded small white pellets with losses of choline and acetylcholine of only 1%. Dried pellets of unlabeled choline and acetylcholine standards were assayed radioenzymatically using [gamma-32P]ATP, choline kinase, and acetylcholinesterase. The net disintegrations per minute of choline[32P]phosphate product was proportional to both the acetylcholine (10-3000 pmol) and choline (30-3000 pmol) standards. The "limit sensitivity" was 8.5 pmol for acetylcholine and 11.4 pmol for choline. Cross-contamination of the choline assay by acetylcholine averaged 1.3%, whereas contamination of the acetylcholine assay by choline averaged 3.1%.

  15. Ion-exclusion chromatography with conductimetric detection of aliphatic carboxylic acids on a weakly acidic cation-exchange resin by elution with benzoic acid-beta-cyclodextrin.

    PubMed

    Tanaka, Kazuhiko; Mori, Masanobu; Xu, Qun; Helaleh, Murad I H; Ikedo, Mikaru; Taoda, Hiroshi; Hu, Wenzhi; Hasebe, Kiyoshi; Fritz, James S; Haddad, Paul R

    2003-05-16

    In this study, an aqueous solution consisting of benzoic acid with low background conductivity and beta-cyclodextrin (beta-CD) of hydrophilic nature and the inclusion effect to benzoic acid were used as eluent for the ion-exclusion chromatographic separation of aliphatic carboxylic acids with different pKa values and hydrophobicity on a polymethacrylate-based weakly acidic cation-exchange resin in the H+ form. With increasing concentration of beta-cyclodextrin in the eluent, the retention times of the carboxylic acids decreased due to the increased hydrophilicity of the polymethacrylate-based cation-exchange resin surface from the adsorption of OH groups of beta-cyclodextrin. Moreover, the eluent background conductivity decreased with increasing concentration of beta-cyclodextrin in 1 mM benzoic acid, which could result in higher sensitivity for conductimetric detection. The ion-exclusion chromatographic separation of carboxylic acids with high resolution and sensitivity was accomplished successfully by elution with a 1 mM benzoic acid-10 mM cyclodextrin solution without chemical suppression.

  16. Ion exchange treatment of rinse water generated in the galvanizing process.

    PubMed

    Marañón, Elena; Fernández, Yolanda; Castrillón, Leonor

    2005-01-01

    A study was conducted of the viability of using the cationic exchange resins Amberlite IR-120 and Lewatit SP-112 to treat rinse water generated in the galvanizing process as well as acidic wastewater containing zinc (Zn) and iron (Fe). Solutions containing either 100 mg/L of Zn at pH 5.6 (rinse water) or Fe and Zn at concentrations of 320 and 200 mg/L at pH 1.5 (acidic water), respectively, were percolated through packed beds until the resins were exhausted. Breakthrough capacities obtained ranged between 1.1 and 1.5 meq metal/mL resin. The elution of metal and the regeneration of resins were performed with hydrochloric acid. The influence of the flowrate used during the loading stage was also studied, with 0.5 bed volumes/min (3.2 cm/min) found to be the optimum flowrate.

  17. Highly porous drug-eluting structures

    PubMed Central

    Elsner, Jonathan J.; Kraitzer, Amir; Grinberg, Orly; Zilberman, Meital

    2012-01-01

    For many biomedical applications, there is need for porous implant materials. The current article focuses on a method for preparation of drug-eluting porous structures for various biomedical applications, based on freeze drying of inverted emulsions. This fabrication process enables the incorporation of any drug, to obtain an “active implant” that releases drugs to the surrounding tissue in a controlled desired manner. Examples for porous implants based on this technique are antibiotic-eluting mesh/matrix structures used for wound healing applications, antiproliferative drug-eluting composite fibers for stent applications and local cancer treatment, and protein-eluting films for tissue regeneration applications. In the current review we focus on these systems. We show that the release profiles of both types of drugs, water-soluble and water-insoluble, are affected by the emulsion's formulation parameters. The former's release profile is affected mainly through the emulsion stability and the resulting porous microstructure, whereas the latter's release mechanism occurs via water uptake and degradation of the host polymer. Hence, appropriate selection of the formulation parameters enables to obtain desired controllable release profile of any bioactive agent, water-soluble or water-insoluble, and also fit its physical properties to the application. PMID:23507890

  18. Selective concentration of aromatic bases from water with a resin adsorbent

    USGS Publications Warehouse

    Stuber, H.A.; Leenheer, J.A.

    1983-01-01

    Aromatic bases are concentrated from water on columns of a resin adsorbent and recovered by aqueous-acid elution. The degree of concentration attainable depends on the ratio of the capacity factor (k) of the neutral form of the amine to that of the ionized form. Capacity factors of ionic forms of amines on XAD-8 resin (a methylacrylic ester polymer) are greater than zero, ranging from 20 to 250 times lower than those of their neutral forms; they increase with increasing hydrophobicity of the amine. Thus, desorption by acid is an edition (k during desorption >0) rather than a displacement (k during desorption = 0) process. The degree of concentration attainable on XAD-8 resin varies with the hydrophobicity of the amine, being limited for hydrophilic solutes (for example, pyridine) by small neutral-form k's, reaching a maximum for amines of intermediate hydrophobicity (for example, quinoline), and decreasing for more hydrophobc solutes (for example, acridine) because of their large ionic-form k's.

  19. Measurement of variation in soil solute tracer concentration across a range of effective pore sizes

    USGS Publications Warehouse

    Harvey, Judson W.

    1993-01-01

    Solute transport concepts in soil are based on speculation that solutes are distributed nonuniformly within large and small pores. Solute concentrations have not previously been measured across a range of pore sizes and examined in relation to soil hydrological properties. For this study, modified pressure cells were used to measure variation in concentration of a solute tracer across a range of pore sizes. Intact cores were removed from the site of a field tracer experiment, and soil water was eluted from 10 or more discrete classes of pore size. Simultaneous changes in water content and unsaturated hydraulic conductivity were determined on cores using standard pressure cell techniques. Bromide tracer concentration varied by as much as 100% across the range of pore sizes sampled. Immediately following application of the bromide tracer on field plots, bromide was most concentrated in the largest pores; concentrations were lower in pores of progressively smaller sizes. After 27 days, bromide was most dilute in the largest pores and concentrations were higher in the smaller pores. A sharp, threefold decrease in specific water capacity during elution indicated separation of two major pore size classes at a pressure of 47 cm H2O and a corresponding effective pore diameter of 70 μm. Variation in tracer concentration, on the other hand, was spread across the entire range of pore sizes investigated in this study. A two-porosity characterization of the transport domain, based on water retention criteria, only broadly characterized the pattern of variation in tracer concentration across pore size classes during transport through a macroporous soil.

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sonoda, Akinaga, E-mail: akinagasonoda@yahoo.co.jp; Nitta, Norihisa; Yamamoto, Takefumi

    PurposeWe investigated the possibility of shortening the time required for loading epirubicin into calibrated polyvinyl alcohol-based hydrogel beads (DC Beads{sup ®}) to be used for transarterial chemoembolization.MethodAfter separating the beads suspended in phosphate-buffered saline (PBS) solution by the use of a sieve (clearance 75 µm), epirubicin hydrochloride (EH) was loaded for 20, 30, or 60 s under vibration into DC beads. The EH loading rate into conventionally prepared (control) beads, i.e., beads loaded for 30 min without vibration, and vibration-loaded beads were calculated from the residual EH concentration in the bead-depleted EH solution. The amount of EH eluted from conventionally and vibration-loadedmore » samples into a PBS solution (pH 7.0) was measured at 15 and 30 min and 1, 2, 6, 12, and 24 h. We also recorded the inhibitory effect of the PBS solution on the loading time. Using frozen sections, the EH load in the beads was evaluated visually under a fluorescence microscope.ResultsSpectrophotometry (495 nm) showed that the loading rate was 98.98 ± 0.34, 99.02 ± 0.32, and 99.50 ± 0.11 % with 20-, 30-, and 60-s vibration, respectively. The eluted rate was statistically similar between vibration- and statically loaded (control) beads. The PBS solution hampered EH loading into the beads. Visually, the distribution of EH in conventionally and vibration-loaded DC beads was similar.DiscussionThe use of vibration and the removal of PBS solution when epirubicin hydrochloride was loaded into DC beads dramatically shortened the loading time of epirubicin hydrochloride into DC beads.« less

  1. An Attempt to Shorten Loading Time of Epirubicin into DC Beads® Using Vibration and a Sieve.

    PubMed

    Sonoda, Akinaga; Nitta, Norihisa; Yamamoto, Takefumi; Tomozawa, Yuki; Ohta, Shinichi; Watanabe, Shobu; Murata, Kiyoshi

    2017-04-01

    We investigated the possibility of shortening the time required for loading epirubicin into calibrated polyvinyl alcohol-based hydrogel beads (DC Beads ® ) to be used for transarterial chemoembolization. After separating the beads suspended in phosphate-buffered saline (PBS) solution by the use of a sieve (clearance 75 µm), epirubicin hydrochloride (EH) was loaded for 20, 30, or 60 s under vibration into DC beads. The EH loading rate into conventionally prepared (control) beads, i.e., beads loaded for 30 min without vibration, and vibration-loaded beads were calculated from the residual EH concentration in the bead-depleted EH solution. The amount of EH eluted from conventionally and vibration-loaded samples into a PBS solution (pH 7.0) was measured at 15 and 30 min and 1, 2, 6, 12, and 24 h. We also recorded the inhibitory effect of the PBS solution on the loading time. Using frozen sections, the EH load in the beads was evaluated visually under a fluorescence microscope. Spectrophotometry (495 nm) showed that the loading rate was 98.98 ± 0.34, 99.02 ± 0.32, and 99.50 ± 0.11 % with 20-, 30-, and 60-s vibration, respectively. The eluted rate was statistically similar between vibration- and statically loaded (control) beads. The PBS solution hampered EH loading into the beads. Visually, the distribution of EH in conventionally and vibration-loaded DC beads was similar. The use of vibration and the removal of PBS solution when epirubicin hydrochloride was loaded into DC beads dramatically shortened the loading time of epirubicin hydrochloride into DC beads.

  2. Elution of Labile Fluorescent Dye from Nanoparticles during Biological Use

    PubMed Central

    Tenuta, Tiziana; Monopoli, Marco P.; Kim, JongAh; Salvati, Anna; Dawson, Kenneth A.; Sandin, Peter; Lynch, Iseult

    2011-01-01

    Cells act as extremely efficient filters for elution of unbound fluorescent tags or impurities associated with nanoparticles, including those that cannot be removed by extensive cleaning. This has consequences for quantification of nanoparticle uptake and sub-cellular localization in vitro and in vivo as a result of the presence of significant amount of labile dye even following extensive cleaning by dialysis. Polyacrylamide gel electrophoresis (PAGE) can be used to monitor the elution of unbound fluorescent probes from nanoparticles, either commercially available or synthesized in-house, and to ensure their complete purification for biological studies, including cellular uptake and sub-cellular localisation. Very different fluorescence distribution within cells is observed after short dialysis times versus following extensive dialysis against a solvent in which the free dye is more soluble, due to the contribution from free dye. In the absence of an understanding of the presence of residual free dye in (most) labeled nanoparticle solutions, the total fluorescence intensity in cells following exposure to nanoparticle solutions could be mis-ascribed to the presence of nanoparticles through the cell, rather than correctly assigned to either a combination of free-dye and nanoparticle-bound dye, or even entirely to free dye depending on the exposure conditions (i.e. aggregation of the particles etc). Where all of the dye is nanoparticle-bound, the particles are highly localized in sub-cellular organelles, likely lysosomes, whereas in a system containing significant amounts of free dye, the fluorescence is distributed through the cell due to the free diffusion of the molecule dye across all cellular barriers and into the cytoplasm. PMID:21998668

  3. Application of a chromatography model with linear gradient elution experimental data to the rapid scale-up in ion-exchange process chromatography of proteins.

    PubMed

    Ishihara, Takashi; Kadoya, Toshihiko; Yamamoto, Shuichi

    2007-08-24

    We applied the model described in our previous paper to the rapid scale-up in the ion exchange chromatography of proteins, in which linear flow velocity, column length and gradient slope were changed. We carried out linear gradient elution experiments, and obtained data for the peak salt concentration and peak width. From these data, the plate height (HETP) was calculated as a function of the mobile phase velocity and iso-resolution curve (the separation time and elution volume relationship for the same resolution) was calculated. The scale-up chromatography conditions were determined by the iso-resolution curve. The scale-up of the linear gradient elution from 5 to 100mL and 2.5L column sizes was performed both by the separation of beta-lactoglobulin A and beta-lactoglobulin B with anion-exchange chromatography and by the purification of a recombinant protein with cation-exchange chromatography. Resolution, recovery and purity were examined in order to verify the proposed method.

  4. Flow optimization study of a batch microfluidics PET tracer synthesizing device

    PubMed Central

    Elizarov, Arkadij M.; Meinhart, Carl; van Dam, R. Michael; Huang, Jiang; Daridon, Antoine; Heath, James R.; Kolb, Hartmuth C.

    2010-01-01

    We present numerical modeling and experimental studies of flow optimization inside a batch microfluidic micro-reactor used for synthesis of human-scale doses of Positron Emission Tomography (PET) tracers. Novel techniques are used for mixing within, and eluting liquid out of, the coin-shaped reaction chamber. Numerical solutions of the general incompressible Navier Stokes equations along with time-dependent elution scalar field equation for the three dimensional coin-shaped geometry were obtained and validated using fluorescence imaging analysis techniques. Utilizing the approach presented in this work, we were able to identify optimized geometrical and operational conditions for the micro-reactor in the absence of radioactive material commonly used in PET related tracer production platforms as well as evaluate the designed and fabricated micro-reactor using numerical and experimental validations. PMID:21072595

  5. Effect of layer thickness on the elution of bulk-fill composite components.

    PubMed

    Rothmund, Lena; Reichl, Franz-Xaver; Hickel, Reinhard; Styllou, Panorea; Styllou, Marianthi; Kehe, Kai; Yang, Yang; Högg, Christof

    2017-01-01

    An increment layering technique in a thickness of 2mm or less has been the standard to sufficiently convert (co)monomers. Bulk fill resin composites were developed to accelerate the restoration process by enabling up to 4mm thick increments to be cured in a single step. The aim of the present study is to investigate the effect of layer thickness on the elution of components from bulk fill composites. The composites ELS Bulk fill, SDR Bulk fill and Venus Bulkfill were polymerized according to the instruction of the manufacturers. For each composite three groups with four samples each (n=4) were prepared: (1) samples with a layer thickness of 2mm; (2) samples with a layer thickness of 4mm and (3) samples with a layer thickness of 6mm. The samples were eluted in methanol and water for 24h and 7 d. The eluates were analyzed by gas chromatography/mass spectrometry (GC/MS). A total of 11 different elutable substances have been identified from the investigated composites. Following methacrylates showed an increase of elution at a higher layer thickness: TEGDMA (SDR Bulk fill, Venus Bulk fill), EGDMA (Venus Bulk fill). There was no significant difference in the elution of HEMA regarding the layer thickness. The highest concentration of TEGDMA was 146μg/mL for SDR Bulk fill at a layer thickness of 6mm after 7 d in water. The highest HEMA concentration measured at 108μg/mL was detected in the methanol eluate of Venus Bulk fill after 7 d with a layer thickness of 6mm. A layer thickness of 4mm or more can lead to an increased elution of some bulk fill components, compared to the elution at a layer thickness of 2mm. Copyright © 2016 The Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  6. Paper-based assay for red blood cell antigen typing by the indirect antiglobulin test.

    PubMed

    Yeow, Natasha; McLiesh, Heather; Guan, Liyun; Shen, Wei; Garnier, Gil

    2016-07-01

    A rapid and simple paper-based elution assay for red blood cell antigen typing by the indirect antiglobulin test (IAT) was established. This allows to type blood using IgG antibodies for the important blood groups in which IgM antibodies do not exist. Red blood cells incubated with IgG anti-D were washed with saline and spotted onto the paper assay pre-treated with anti-IgG. The blood spot was eluted with an elution buffer solution in a chromatography tank. Positive samples were identified by the agglutinated and fixed red blood cells on the original spotting area, while red blood cells from negative samples completely eluted away from the spot of origin. Optimum concentrations for both anti-IgG and anti-D were identified to eliminate the washing step after the incubation phase. Based on the no-washing procedure, the critical variables were investigated to establish the optimal conditions for the paper-based assay. Two hundred ten donor blood samples were tested in optimal conditions for the paper test with anti-D and anti-Kell. Positive and negative samples were clearly distinguished. This assay opens up new applications of the IAT on paper including antibody detection and blood donor-recipient crossmatching and extends its uses into non-blood typing applications with IgG antibody-based diagnostics. Graphical abstract A rapid and simple paper-based assay for red blood cell antigen typing by the indirect antiglobulin test.

  7. DC bead: in vitro characterization of a drug-delivery device for transarterial chemoembolization.

    PubMed

    Lewis, Andrew L; Gonzalez, M Victoria; Lloyd, Andrew W; Hall, Brenda; Tang, Yiqing; Willis, Sean L; Leppard, Simon W; Wolfenden, Laura C; Palmer, Rosemary R; Stratford, Peter W

    2006-02-01

    The purpose of this investigation is to present the in vitro characterization and detailed drug-loading procedure for DC Bead, a microsphere product that can be loaded with chemotherapeutic agents for embolization. DC Bead is an embolic microsphere product that is capable of being loaded with anthracycline drugs such as doxorubicin just before administration in a transarterial chemoembolization (TACE) procedure. Beads can be loaded from solutions prepared from doxorubicin powder or the doxorubicin HCl formulation. In this evaluation, bead sizes were measured by optical microscopy with video imaging. Gravimetric analysis demonstrated the effect of drug loading on bead water content, and its consequent impact on bead compressibility was determined. The subsequent deliverability of the beads was assessed by mixing the beads with contrast medium and saline solution and passing the beads through an appropriately sized microcatheter. A T-cell apparatus was used to monitor the in vitro elution of the drug from the beads over a period of 24 hours in various elution media. DC Bead spheres could be easily loaded with doxorubicin to a recommended level of 25 mg/mL of hydrated beads by immersion of the beads in the drug solution for 10-120 minutes depending on microsphere size. Other commercial embolic microspheres were shown not to load doxorubicin to the same extent or release it in the same fashion and were considered unsuitable for local drug delivery. Maximum theoretic capacity for DC Bead was approximately 45 mg/mL. Increase in doxorubicin loading resulted in a concomitant decrease in water content and consequential increase in bead resistance to compression force. Drug loading also resulted in a decrease in the average size of the beads, which was dependent on bead size and drug dose. This did not impact bead delivery at any drug loading level to a maximum of 37.5 mg/mL. Beads 100-700 microm in size could be delivered through 2.7-F microcatheters, whereas the 700-900-microm range required 3-F catheters. Modeling of the kinetics of drug elution from the beads in vitro at a loading dose of 25 mg/mL yielded calculated half-lives of 150 hours for the 100-300-microm range to a maximum of 1,730 hours for the 700-900-microm size range, which was dependent on the ionic strength of the elution medium. For comparison, there was a rapid loss of drug from an unstable Lipiodol emulsion with a half-life of approximately 1 hour. DC Bead can be loaded with doxorubicin to provide an accurate dosage of drug per unit volume of beads. Drug elution is dependent on ion exchange with the surrounding environment and is controlled and sustained, unlike the rapid separation of the drug from Lipiodol. Drug loading has no impact on the handling and deliverability of the beads, making them suitable for superselective TACE.

  8. Local Drug Delivery to Prevent Restenosis

    PubMed Central

    Seedial, Stephen M.; Ghosh, Soumojit; Saunders, R. Scott; Suwanabol, Pasithorn A.; Shi, Xudong; Liu, Bo; Kent, K. Craig

    2013-01-01

    Introduction Despite significant advances in vascular biology, bioengineering and pharmacology, restenosis remains a limitation to the overall efficacy of vascular reconstructions, both percutaneous and open. Although the pathophysiology of intimal hyperplasia is complex, a number of drugs and/or molecular tools have been identified that can prevent restenosis. Moreover, the focal nature of this process lends itself to treatment with local drug administration. In this article we provide a broad overview of current and future techniques for local drug delivery that have been developed to prevent restenosis following vascular intervention. Methods A systematic electronic literature search using PubMed was performed for all accessible published articles through September 2012. In an effort to remain current, additional searches were performed for abstracts presented at relevant societal meetings, filed patents, clinical trials and funded NIH awards. Results The efficacy of local drug delivery has been demonstrated in the coronary circulation with the current clinical use of drug-eluting stents (DES). Until recently, however, DES were not found to be efficacious in the peripheral circulation. Further pursuit of intraluminal devices has led to the development of balloon-based technologies with a recent surge in trials involving drug-eluting balloons. Early data appears encouraging, particularly for treatment of lesions in the superficial femoral artery, with several devices having recently received the CE mark in Europe. Investigators have also explored periadventitial application of biomaterials containing anti-restenotic drugs, an approach that could be particularly useful for surgical bypass or endarterectomy. In the past systemic drug delivery has been unsuccessful, however, there has been recent exploration of intravenous delivery of drugs designed specifically to target injured or reconstructed arteries. Our review revealed a multitude of additional interesting strategies including more than 65 new patents issued over the past two years for approaches to local drug delivery focused on preventing restenosis. Conclusion Restenosis following intraluminal or open vascular reconstruction remains an important clinical problem. Success in the coronary circulation has not translated into solutions for the peripheral arteries. However, our review of the literature reveals a number of promising approaches including drug-eluting balloons, periadventitial drug delivery as well as targeted systemic therapies. These innovations as well as others suggest that the future is bright and a solution for preventing restenosis in peripheral vessels will soon be at hand. PMID:23601595

  9. Bare metal stents, durable polymer drug eluting stents, and biodegradable polymer drug eluting stents for coronary artery disease: mixed treatment comparison meta-analysis

    PubMed Central

    Toklu, Bora; Amoroso, Nicholas; Fusaro, Mario; Kumar, Sunil; Hannan, Edward L; Faxon, David P; Feit, Frederick

    2013-01-01

    Objective To compare the efficacy and safety of biodegradable polymer drug eluting stents with those of bare metal stents and durable polymer drug eluting stents. Design Mixed treatment comparison meta-analysis of 258 544 patient years of follow-up from randomized trials. Data sources and study selection PubMed, Embase, and Central were searched for randomized trials comparing any of the Food and Drug Administration approved durable polymer drug eluting stents (sirolimus eluting, paclitaxel eluting, cobalt chromium everolimus eluting, platinum chromium everolimus eluting, zotarolimus eluting-Endeavor, and zotarolimus eluting-Resolute) or biodegradable polymer drug eluting stents, with each other or against bare metal stents. Outcomes Long term efficacy (target vessel revascularization, target lesion revascularization) and safety (death, myocardial infarction, stent thrombosis). Landmark analysis at more than one year was evaluated to assess the potential late benefit of biodegradable polymer drug eluting stents. Results From 126 randomized trials and 258 544 patient years of follow-up, for long term efficacy (target vessel revascularization), biodegradable polymer drug eluting stents were superior to paclitaxel eluting stents (rate ratio 0.66, 95% credibility interval 0.57 to 0.78) and zotarolimus eluting stent-Endeavor (0.69, 0.56 to 0.84) but not to newer generation durable polymer drug eluting stents (for example: 1.03, 0.89 to 1.21 versus cobalt chromium everolimus eluting stents). Similarly, biodegradable polymer drug eluting stents were superior to paclitaxel eluting stents (rate ratio 0.61, 0.37 to 0.89) but inferior to cobalt chromium everolimus eluting stents (2.04, 1.27 to 3.35) for long term safety (definite stent thrombosis). In the landmark analysis after one year, biodegradable polymer drug eluting stents were superior to sirolimus eluting stents for definite stent thrombosis (rate ratio 0.29, 0.10 to 0.82) but were associated with increased mortality compared with cobalt chromium everolimus eluting stents (1.52, 1.02 to 2.22). Overall, among all stent types, the newer generation durable polymer drug eluting stents (zotarolimus eluting stent-Resolute, cobalt chromium everolimus eluting stents, and platinum chromium everolimus eluting stents) were the most efficacious (lowest target vessel revascularization rate) stents, and cobalt chromium everolimus eluting stents were the safest with significant reductions in definite stent thrombosis (rate ratio 0.35, 0.21 to 0.53), myocardial infarction (0.65, 0.55 to 0.75), and death (0.72, 0.58 to 0.90) compared with bare metal stents. Conclusions Biodegradable polymer drug eluting stents are superior to first generation durable polymer drug eluting stents but not to newer generation durable polymer stents in reducing target vessel revascularization. Newer generation durable polymer stents, and especially cobalt chromium everolimus eluting stents, have the best combination of efficacy and safety. The utility of biodegradable polymer stents in the context of excellent clinical outcomes with newer generation durable polymer stents needs to be proven. PMID:24212107

  10. Recovery of Uranium from Sodium Carbonate Solutions with Dowex I Anion Exchangers; RECUPERACION DEL URANIO DE SOLUCIONES. DE CARBONATO SODICO MEDIANTE INTERCAMBIO ANIONICO CON RESINA DOWEX I

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Urgell, M.; Bustamante, J.A.P.; Rodriguez, T.B.

    1959-01-01

    Synthetic carbonate solutions were used to study the recovery of uranium with Dowex-1. In the first part of the study the capacity of the resin for uranium fixation is investigated as a function of the solution concentration, and the flow velocity. The ideal thickness of the resin bed is investigated. The optimum conditions for elution with various salts and salt mixtures are established. In the last pant, the interference caused by an excess of carbonate and the presence of aluminate or phosphate is considered. (J.S.R.)

  11. A Calcium Enterolith in a Patient with Crohn's Disease and Its In Vitro Dissolubility in Citric Acid

    PubMed Central

    Urata, Haruo; Ohmori, Masayasu; Kondo, Yoshitaka; Kawahara, Yoshiro; Okada, Hiroyuki

    2017-01-01

    The microstructure and dissolubility of a calcified enterolith and enterolith pieces removed from a 26-year-old Japanese woman with Crohn's disease were analyzed using scanning electron microscopy and energy dispersive X-ray spectroscopy. The enterolith showed a multilayered structure with fatty acid calcium and magnesium phosphate. The amount of calcium, magnesium, and phosphate decreased after they were immersed in a citric acid solution, suggesting a potential contribution of acidic aqueous solution to elute inorganic substances contained in calcified enteroliths. This is the first study to investigate the in vitro dissolubility of calcified enteroliths induced by citric acid solution. PMID:29082049

  12. Direct probing of chromatography columns by laser-induced fluorescence

    NASA Astrophysics Data System (ADS)

    McGuffin, V. L.

    1992-12-01

    This report summarizes the progress and accomplishments of this research project from 1 Sep. 1989 to 28 Feb. 1993. During this period, we have accomplished all of the primary scientific objectives of the research proposal: (1) constructed and evaluated a laser-induced fluorescence detection system that allows direct examination of the chromatographic column, (2) examined nonequilibrium processes that occur upon solute injection and elution, (3) examined solute retention in liquid chromatography as a function of temperature and pressure, (4) examined solute zone dispersion in liquid chromatography as a function of temperature and pressure, and (5) developed appropriate theoretical models to describe these phenomena. In each of these studies, substantial knowledge has been gained of the fundamental processes that are responsible for chromatographic separations. In addition to these primary research objectives, we have made significant progress in three related areas: (1) examined pyrene as a fluorescent polarity probe in supercritical fluids and liquids as a function of temperature and pressure, (2) developed methods for the class-selective identification of polynuclear aromatic hydrocarbons in coal-derived fluids by microcolumn liquid chromatography with fluorescence quenching detection, and (3) developed methods for the determination of saturated and unsaturated (including omega-3) fatty acids in fish oil extracts by microcolumn liquid chromatography with laser-induced fluorescence detection. In these studies, the advanced separation and detection techniques developed in our laboratory are applied to practical problems of environmental and biomedical significance.

  13. Paclitaxel Drug-Eluting Stents in Peripheral Arterial Disease: A Health Technology Assessment

    PubMed Central

    2015-01-01

    Background Peripheral arterial disease is a condition in which atherosclerotic plaques partially or completely block blood flow to the legs. Although percutaneous transluminal angioplasty and metallic stenting have high immediate success rates in treating peripheral arterial disease, long-term patency and restenosis rates in long and complex lesions remain unsatisfactory. Objective The objective of this analysis was to evaluate the clinical effectiveness, safety, cost-effectiveness and budget impact of Zilver paclitaxel self-expanding drug-eluting stents for the treatment of de novo or restenotic lesions in above-the-knee peripheral arterial disease. Data Sources Literature searches were performed using Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid Embase, EBSCO Cumulative Index to Nursing & Allied Health Literature (CINAHL), and EBM Reviews. For the economic review, a search filter was applied to limit search results to economics-related literature. Data sources for the budget impact analysis included expert opinion, published literature, and Ontario administrative data. Review Methods Systematic reviews, meta-analyses, randomized controlled trials, and observational studies were included in the clinical effectiveness review, and full economic evaluations were included in the economic literature review. Studies were included if they examined the effect of Zilver paclitaxel drug-eluting stents in de novo or restenotic lesions in above-the-knee arteries. For the budget impact analysis, 3 scenarios were constructed based on different assumptions. Results One randomized controlled trial reported a significantly higher patency rate with Zilver paclitaxel drug-eluting stents for lesions ≤ 14 cm than with angioplasty or bare metal stents. One observational study showed no difference in patency rates between Zilver paclitaxel drug-eluting stents and paclitaxel drug-coated balloons. Zilver paclitaxel drug-eluting stents were associated with a significantly higher event-free survival rate than angioplasty, but the event-free survival rate was similar for Zilver paclitaxel drug-eluting stents and paclitaxel drug-coated balloons. No economic evaluations compared Zilver paclitaxel drug-eluting stents with bare metal stents or angioplasty for peripheral arterial disease. A budget impact analysis showed that the cost savings associated with funding of Zilver paclitaxel drug-eluting stents would be $470,000 to $640,000 per year, assuming that the use of the Zilver paclitaxel drug-eluting stent was associated with a lower risk of subsequent revascularization. Conclusions Based on evidence of low to moderate quality, Zilver paclitaxel drug-eluting stents were associated with a higher patency rate than angioplasty or bare metal stents, and with fewer adverse events than angioplasty. The effectiveness and safety of Zilver paclitaxel drug-eluting stents and paclitaxel drug-coated balloons were similar. PMID:26719778

  14. Characterization of Virus Adsorption by Using DEAE-Sepharose and Octyl-Sepharose†

    PubMed Central

    Shields, Patricia A.; Farrah, Samuel R.

    2002-01-01

    Viruses were characterized by their adsorption to DEAE-Sepharose or by their elution from octyl-Sepharose by using buffered solutions of sodium chloride with different ionic strengths. Viruses whose adsorption to DEAE-Sepharose was reduced most rapidly by an increase in the sodium chloride concentration were considered to have the weakest electrostatic interactions with the solids; these viruses included MS2, E1, and φX174. Viruses whose adsorption to DEAE-Sepharose was reduced least rapidly were considered to have the strongest electrostatic interactions with the column; these viruses included P1, T4, T2, and E5. All of the viruses studied adsorbed to octyl-Sepharose in the presence of 4 M NaCl. Viruses that were eluted most rapidly following a decrease in the concentration of NaCl were considered to have the weakest hydrophobic interactions with the column; these viruses included φX174, CB4, and E1. Viruses that were eluted least rapidly from the columns after the NaCl concentration was decreased were considered to have the strongest hydrophobic interactions with the column; these viruses included f2, MS2, and E5. PMID:12147497

  15. Fabrication of high-capacity polyelectrolyte brush-grafted porous AAO-silica composite membrane via RAFT polymerization.

    PubMed

    Song, Cunfeng; Wang, Meijie; Liu, Xin; Wang, He; Chen, Xiaoling; Dai, Lizong

    2017-09-01

    Surface-initiated reversible addition-fragmentation chain transfer (RAFT) polymerization has been utilized to fabricate high-capacity strong anion-exchange (AEX) membrane for the separation of protein. By means of RAFT polymerization, quaternized poly(3-(methacrylamidomethyl)-pyridine) brushes formed 3-dimensional nanolayers on the surface of porous anodic aluminum oxide (AAO)-silica composite membrane. The surface properties of the membranes were analyzed by SEM, water contact angle, ATR-FTIR, XPS and TGA. To investigate the adsorption performance, the new AEX membranes were applied to recover a model protein, ovalbumin (OVA). High adsorption capacities of 95.8mg/g membranes (static) and 65.3mg/g membranes (dynamic) were obtained at ambient temperature. In the further studies, up to 90% of the adsorbed OVA was efficiently eluted by using phosphate buffer-1M NaCl as elution medium. The successful separation of OVA with high purity from a mixture protein solution was also achieved by using the AEX membranes. The present study demonstrated that under mild reaction condition, RAFT polymerization can be used to fabricate ion-exchange membrane which has many remarkable features, such as high capacity and selectivity, easy elution and so on. Copyright © 2017. Published by Elsevier B.V.

  16. Correlating cytotoxicity to elution behaviors of composite resins in term of curing kinetic.

    PubMed

    Meng, Junquan; Yang, Huichuan; Cao, Man; Li, Lei; Cai, Qing

    2017-09-01

    Cytotoxicity of photocurable composite resins is a key issue for their safe use in dental restoration. Curing kinetic and elution behaviors of the composite resin would have decisive effects on its cytotoxicity. In this study, composite resins composed of bisphenol-glycidyl dimethacrylate (Bis-GMA), triethyleneglycol dimethacrylate (TEGDMA), camphorquinone (CQ), N,N-dimethylaminoethyl methacrylate (DMAEMA) and barium glass powders were prepared by setting the photoinitiators CQ/DMAEMA at 0.5wt%, 1wt% or 3wt% of the total weight of Bis-GMA/TEGDMA. The ratio of Bis-GMA/TEGDMA was 6:4, the ratio of CQ/DMAEMA was 1:1, and the incorporated inorganic powder was 75wt%. Then, curing kinetics were studied by using real-time Fourier transform infrared spectroscopy (FTIR) and photo-DSC (differential scanning calorimeter). Elution behaviors in both ethanol solution and deionized water were monitored by using liquid chromatogram/mass spectrometry (LC/MS). Cytotoxicity was evaluated by in vitro culture of L929 fibroblasts. Finally, they were all analyzed and correlated in terms of initiator contents. It was found that the commonly used 0.5wt% of photoinitiators was somewhat insufficient in obtaining composite resin with low cytotoxicity. Copyright © 2017. Published by Elsevier B.V.

  17. Characterization of virus adsorption by using DEAE-sepharose and octyl-sepharoser.

    PubMed

    Shields, Patricia A; Farrah, Samuel R

    2002-08-01

    Viruses were characterized by their adsorption to DEAE-Sepharose or by their elution from octyl-Sepharose by using buffered solutions of sodium chloride with different ionic strengths. Viruses whose adsorption to DEAE-Sepharose was reduced most rapidly by an increase in the sodium chloride concentration were considered to have the weakest electrostatic interactions with the solids; these viruses included MS2, E1, and phiX174. Viruses whose adsorption to DEAE-Sepharose was reduced least rapidly were considered to have the strongest electrostatic interactions with the column; these viruses included P1, T4, T2, and E5. All of the viruses studied adsorbed to octyl-Sepharose in the presence of 4 M NaCl. Viruses that were eluted most rapidly following a decrease in the concentration of NaCl were considered to have the weakest hydrophobic interactions with the column; these viruses included phiX174, CB4, and E1. Viruses that were eluted least rapidly from the columns after the NaCl concentration was decreased were considered to have the strongest hydrophobic interactions with the column; these viruses included f2, MS2, and E5.

  18. [Aluminum dissolution and changes of pH in soil solution during sorption of copper by aggregates of paddy soil].

    PubMed

    Xu, Hai-Bo; Zhao, Dao-Yuan; Qin, Chao; Li, Yu-Jiao; Dong, Chang-Xun

    2014-01-01

    Size fractions of soil aggregates in Lake Tai region were collected by the low-energy ultrasonic dispersion and the freeze-desiccation methods. The dissolution of aluminum and changes of pH in soil solution during sorption of Cu2+ and changes of the dissolution of aluminum at different pH in the solution of Cu2+ by aggregates were studied by the equilibrium sorption method. The results showed that in the process of Cu2+ sorption by aggregates, the aluminum was dissoluted and the pH decreased. The elution amount of aluminum and the decrease of pH changed with the sorption of Cu2+, both increasing with the increase of Cu2+ sorption. Under the same conditions, the dissolution of aluminum and the decrease of pH were in the order of coarse silt fraction > silt fraction > sand fraction > clay fraction, which was negatively correlated with the amount of iron oxide, aluminum and organic matter. It suggested that iron oxide, aluminum and organic matters had inhibitory and buffering effect on the aluminum dissolution and the decrease of pH during the sorption of Cu2+.

  19. Covalently Linked Tandem Lesions in DNA

    PubMed Central

    Patrzyc, Helen B.; Dawidzik, Jean B.; Budzinski, Edwin E.; Freund, Harold G.; Wilton, John H.; Box, Harold C.

    2013-01-01

    Reactive oxygen species (ROS) generate a type of DNA damage called tandem lesions, two adjacent nucleotides both modified. A subcategory of tandem lesions consists of adjacent nucleotides linked by a covalent bond. Covalently linked tandem lesions generate highly characteristic liquid chromotography-tandem mass spectrometry (LC-MS/MS) elution profiles. We have used this property to comprehensively survey X-irradiated DNA for covalently linked tandem lesions. A total of 15 tandem lesions were detected in DNA irradiated in deoxygenated aqueous solution, five tandem lesions were detected in DNA that was irradiated in oxygenated solution. PMID:23106212

  20. Tungsten-188/carrier-free rhenium-188 perrhenic acid generator system

    DOEpatents

    Knapp, F.F. Jr.; Lisic, E.C.; Mirzadeh, S.; Callahan, A.P.

    1994-01-04

    A generator system has been invented for providing a carrier-free radioisotope in the form of an acid comprises a chromatography column in tandem fluid connection with an ion exchange column, the chromatography column containing a charge of a radioactive parent isotope. The chromatography column, charged with a parent isotope, is eluted with an alkali metal salt solution to generate the radioisotope in the form of an intermediate solution, which is passed through the ion-exchange column to convert the radioisotope to a carrier-free acid form. 1 figure.

  1. Determining gold in water by anion-exchange batch extraction

    USGS Publications Warehouse

    McHugh, J.B.

    1986-01-01

    This paper describes a batch procedure for determining gold in natural waters. It is completely adaptable to field operations. The water samples are filtered and acidified before they are equilibrated with an anion-exchange resin by shaking. The gold is then eluted with acetone-nitric acid solution, and the eluate evaporated to dryness. The residue is taken up in hydrobromic acid-bromine solution and the gold is extracted with methyl isobutyl ketone. The extract is electrothermally atomized in an atomic-absorption spectrophotometer. The limit of determination is 1 ng 1. ?? 1986.

  2. Simple practical approach for sample loading prior to DNA extraction using a silica monolith in a microfluidic device.

    PubMed

    Shaw, Kirsty J; Joyce, Domino A; Docker, Peter T; Dyer, Charlotte E; Greenman, John; Greenway, Gillian M; Haswell, Stephen J

    2009-12-07

    A novel DNA loading methodology is presented for performing DNA extraction on a microfluidic system. DNA in a chaotropic salt solution was manually loaded onto a silica monolith orthogonal to the subsequent flow of wash and elution solutions. DNA was successfully extracted from buccal swabs using electro-osmotic pumping (EOP) coupled with in situ reagents contained within a 1.5% agarose gel matrix. The extracted DNA was of sufficient quantity and purity for polymerase chain reaction (PCR) amplification.

  3. Development and validation of a gas chromatography/mass spectrometry procedure for confirmation of para-toluenesulfonamide in edible fish fillet tissue

    USGS Publications Warehouse

    Idowu, O.R.; Kijak, P.J.; Meinertz, J.R.; Schmidt, L.J.

    2004-01-01

    Chloramine-T is a disinfectant being developed as a treatment for bacterial gill disease in cultured fish. As part of the drug approval process, a method is required for the confirmation of chloramine-T residues in edible fish tissue. The marker residue that will be used to determine the depletion of chloramine-T residues from the edible tissue of treated fish is para-toluenesulfonamide (p-TSA), a metabolite of chloramine-T. The development and validation of a procedure for the confirmation of p-TSA is described. Homogenized fish tissue is dried by mixing with anhydrous sodium sulfate, and the mixture is extracted with methylene chloride. The extract is passed through a silica gel solid-phase extraction column, from which p-TSA is subsequently eluted with acetonitrile. The acetonitrile extract is evaporated, and the oily residue is dissolved in hexane. The hexane solution is shaken with fresh acetonitrile. The acetonitrile solution is evaporated and the residue is redissolved in dilute potassium hydroxide solution. The aqueous solution is extracted with methylene chloride to further remove more of the fat co-extractive. The aqueous solution is reacted with pentafluorobenzyl bromide in presence of tetrabutylammonium hydrogensulfate. The resulting di-(pentafluorobenzyl) derivative of p-TSA is analyzed by gas chromatography/mass spectrometry. This method permits the confirmation of p-TSA in edible fish tissue at 20 ppb.

  4. Development and validation of a gas chromatography/mass spectrometry procedure for confirmation of para-toluenesulfonamide in edible fish fillet tissue.

    PubMed

    Idowu, Olutosin R; Kijak, Philip J; Meinertz, Jeffery R; Schmidt, Larry J

    2004-01-01

    Chloramine-T is a disinfectant being developed as a treatment for bacterial gill disease in cultured fish. As part of the drug approval process, a method is required for the confirmation of chloramine-T residues in edible fish tissue. The marker residue that will be used to determine the depletion of chloramine-T residues from the edible tissue of treated fish is para-toluenesulfonamide (p-TSA), a metabolite of chloramine-T. The development and validation of a procedure for the confirmation of p-TSA is described. Homogenized fish tissue is dried by mixing with anhydrous sodium sulfate, and the mixture is extracted with methylene chloride. The extract is passed through a silica gel solid-phase extraction column, from which p-TSA is subsequently eluted with acetonitrile. The acetonitrile extract is evaporated, and the oily residue is dissolved in hexane. The hexane solution is shaken with fresh acetonitrile. The acetonitrile solution is evaporated and the residue is redissolved in dilute potassium hydroxide solution. The aqueous solution is extracted with methylene chloride to further remove more of the fat co-extractive. The aqueous solution is reacted with pentafluorobenzyl bromide in presence of tetrabutylammonium hydrogensulfate. The resulting di-(pentafluorobenzyl) derivative of p-TSA is analyzed by gas chromatography/mass spectrometry. This method permits the confirmation of p-TSA in edible fish tissue at 20 ppb.

  5. Enhancing recovery of recombinant hepatitis B surface antigen in lab-scale and large-scale anion-exchange chromatography by optimizing the conductivity of buffers.

    PubMed

    Mojarrad Moghanloo, Gol Mohammad; Khatami, Maryam; Javidanbardan, Amin; Hosseini, Seyed Nezamedin

    2018-01-01

    In biopharmaceutical science, ion-exchange chromatography (IEC) is a well-known purification technique to separate the impurities such as host cell proteins from recombinant proteins. However, IEC is one of the limiting steps in the purification process of recombinant hepatitis B surface antigen (rHBsAg), due to its low recovery rate (<50%). In the current study, we hypothesized that ionic strengths of IEC buffers are easy-to-control parameters which can play a major role in optimizing the process and increasing the recovery. Thus, we investigated the effects of ionic strengths of buffers on rHBsAg recovery via adjusting Tris-HCl and NaCl concentrations. Increasing the conductivity of equilibration (Eq.), washing (Wash.) and elution (Elut.) buffers from their initial values of 1.6 mS/cm, 1.6 mS/cm, and 7.0 mS/cm to 1.6 mS/cm, 7 mS/cm and 50 mS/cm, respectively yielded an average recovery rate of 82% in both lab-scale and large-scale weak anion-exchange chromatography without any harsh effect on the purity percentage of rHBsAg. The recovery enhancement via increasing the conductivity of Eq. and Wash. buffers can be explained by their roles in reducing the binding strength and aggregation of retained particles in the column. Moreover, further increase in the salt concentration of Elut. Buffer could substantially promote the ion exchange process and the elution of retained rHBsAg. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. Method and system for radioisotope generation

    DOEpatents

    Toth, James J.; Soderquist, Chuck Z.; Greenwood, Lawrence R.; Mattigod, Shas V.; Fryxell, Glen E.; O'Hara, Matthew J.

    2014-07-15

    A system and a process for producing selected isotopic daughter products from parent materials characterized by the steps of loading the parent material upon a sorbent having a functional group configured to selectively bind the parent material under designated conditions, generating the selected isotopic daughter products, and eluting said selected isotopic daughter products from the sorbent. In one embodiment, the process also includes the step of passing an eluent formed by the elution step through a second sorbent material that is configured to remove a preselected material from said eluent. In some applications a passage of the material through a third sorbent material after passage through the second sorbent material is also performed.

  7. Optimization of the Determination Method for Dissolved Cyanobacterial Toxin BMAA in Natural Water.

    PubMed

    Yan, Boyin; Liu, Zhiquan; Huang, Rui; Xu, Yongpeng; Liu, Dongmei; Lin, Tsair-Fuh; Cui, Fuyi

    2017-10-17

    There is a serious dispute on the existence of β-N-methylamino-l-alanine (BMAA) in water, which is a neurotoxin that may cause amyotrophic lateral sclerosis/Parkinson's disease (ALS/PDC) and Alzheimer' disease. It is believed that a reliable and sensitive analytical method for the determination of BMAA is urgently required to resolve this dispute. In the present study, the solid phase extraction (SPE) procedure and the analytical method for dissolved BMAA in water were investigated and optimized. The results showed both derivatized and underivatized methods were qualified for the measurement of BMAA and its isomer in natural water, and the limit of detection and the precision of the two methods were comparable. Cartridge characteristics and SPE conditions could greatly affect the SPE performance, and the competition of natural organic matter is the primary factor causing the low recovery of BMAA, which was reduced from approximately 90% in pure water to 38.11% in natural water. The optimized SPE method for BMAA was a combination of rinsed SPE cartridges, controlled loading/elution rates and elution solution, evaporation at 55 °C, reconstitution of a solution mixture, and filtration by polyvinylidene fluoride membrane. This optimized method achieved > 88% recovery of BMAA in both algal solution and river water. The developed method can provide an efficient way to evaluate the actual concentration levels of BMAA in actual water environments and drinking water systems.

  8. Effects of ammonia and hydrogen sulfide on physical and biochemical properties of the claw horn of Holstein cows

    PubMed Central

    Higuchi, Hidetoshi; Kurumado, Hisatoshi; Mori, Maya; Degawa, Aiko; Fujisawa, Hideyo; Kuwano, Atsutoshi; Nagahata, Hajime

    2009-01-01

    The effects of ammonia and hydrogen sulfide on the physical and biochemical properties of the claw horn of Holstein cows were evaluated. Significant (P < 0.05, 0.01) decreases in hardness and elasticity were found in claw horns soaked in ammonia (NH3) and hydrogen sulfide (H2S) solutions compared with those that were soaked in water for 12, 24, and 48 h. Water absorption rate, as a indicator of permeability barrier function, increased significantly (P < 0.05) over time during the soaking period and was found to be dependent on the concentrations of NH3 and H2S in the solutions. The contents of ceramide, the main lipid component for the permeability barrier system of the stratum corneum, were significantly decreased in claw horns soaked in NH3 and H2S solutions compared with the values before soaking. Quantities of eluted protein released from claw horns treated with NH3 and H2S solutions were approximately 20 times and 30 to 40 times greater than those released from claw horns treated with water alone. Interestingly, the quantities of cytokeratin 10, the main cytoskeletal protein of the stratum corneum, eluted from claw horns treated with NH3 and H2S solutions were markedly greater than the quantity released from horns soaked in water. Our results suggest that abnormal changes in the physical property of claw horn caused by NH3 and H2S treatment are due to disruption of the biochemical property of the claw horn induced by these chemical agents derived from slurry. PMID:19337390

  9. Polyvinylidene Fluoride Micropore Membranes as Solid-Phase Extraction Disk for Preconcentration of Nanoparticulate Silver in Environmental Waters.

    PubMed

    Zhou, Xiao-Xia; Lai, Yu-Jian; Liu, Rui; Li, Sha-Sha; Xu, Jing-Wen; Liu, Jing-Fu

    2017-12-05

    Efficient separation and preconcentration of trace nanoparticulate silver (NAg) from large-volume environmental waters is a prerequisite for reliable analysis and therefore understanding the environmental processes of silver nanoparticles (AgNPs). Herein, we report the novel use of polyvinylidene fluoride (PVDF) filter membrane for disk-based solid phase extraction (SPE) of NAg in 1 L of water samples with the disk-based SPE system, which consists of a syringe pump and a syringe filter holder to embed the filter membrane. While the PVDF membrane can selectively adsorb NAg in the presence of Ag + , aqueous solution of 2% (m/v) FL-70 is found to efficiently elute NAg. Analysis of NAg is performed following optimization of filter membrane and elution conditions with an enrichment factor of 1000. Additionally, transmission electron microscopy (TEM), UV-vis spectroscopy, and size-exclusion chromatography coupled with ICP-MS (SEC-ICP-MS) analysis showed that the extraction gives rise to no change in NAg size or shape, making this method attractive for practical applications. Furthermore, feasibility of the protocol is verified by applying it to extract NAg in four real waters with recoveries of 62.2-80.2% at 0.056-0.58 μg/L spiked levels. This work will facilitate robust studies of trace NAg transformation and their hazard assessments in the environment.

  10. Evaluation of positively charged alumina nanofibre cartridge filters for the primary concentration of noroviruses, adenoviruses and male-specific coliphages from seawater.

    PubMed

    Gibbons, C D; Rodríguez, R A; Tallon, L; Sobsey, M D

    2010-08-01

    To evaluate the electropositive, alumina nanofibre (NanoCeram) cartridge filter as a primary concentration method for recovering adenovirus, norovirus and male-specific coliphages from natural seawater. Viruses were concentrated from 40 l of natural seawater using a NanoCeram cartridge filter and eluted from the filter either by soaking the filter in eluent or by recirculating the eluent continuously through the filter using a peristaltic pump. The elution solution consisted of 3% beef extract and 0.1 mol l(-1) of glycine. The method using a peristaltic pump was more effective in removing the viruses from the filter. High recoveries of norovirus and male-specific coliphages (>96%) but not adenovirus (<3%) were observed from seawater. High adsorption to the filter was observed for adenovirus and male-specific coliphages (>98%). The adsorption and recovery of adenovirus and male-specific coliphages were also determined for fresh finished water and source water. The NanoCeram cartridge filter was an effective primary concentration method for the concentration of norovirus and male-specific coliphages from natural seawater, but not for adenovirus, in spite of the high adsorption of adenovirus to the filter. This study demonstrates that NanoCeram cartridge filter is an effective primary method for concentrating noroviruses and male-specific coliphages from seawater, thereby simplifying collection and processing of water samples for virus recovery.

  11. A simple method to separate red wine nonpolymeric and polymeric phenols by solid-phase extraction.

    PubMed

    Pinelo, Manuel; Laurie, V Felipe; Waterhouse, Andrew L

    2006-04-19

    Simple polyphenols and tannins differ in the way that they contribute to the organoleptic profile of wine and their effects on human health. Very few straightforward techniques to separate red wine nonpolymeric phenols from the polymeric fraction are available in the literature. In general, they are complex, time-consuming, and generate large amounts of waste. In this procedure, the separation of these compounds was achieved using C18 cartridges, three solvents with different elution strengths, and pH adjustments of the experimental matrices. Two full factorial 2(3) experimental designs were performed to find the optimal critical variables and their values, allowing for the maximization of tannin recovery and separation efficiency (SE). Nonpolymeric phenols such as phenolic acids, monomers, and oligomers of flavonol and flavan-3-ols and anthocyanins were removed from the column by means of an aqueous solvent followed by ethyl acetate. The polymeric fraction was then eluted with a combination of methanol/acetone/water. The best results were attained with 1 mL of wine sample, a 10% methanol/water solution (first eluant), ethyl acetate (second eluant), and 66% acetone/water as the polymeric phenols-eluting solution (third eluant), obtaining a SE of ca. 90%. Trials with this method on fruit juices also showed high separation efficiency. Hence, this solid-phase extraction method has been shown to be a simple and efficient alternative for the separation of nonpolymeric phenolic fractions and the polymeric ones, and this method could have important applications to sample purification prior to biological testing due to the nonspecific binding of polymeric phenolics to nearly all enzymes and receptor sites.

  12. Purification of Bacteriophages Using Anion-Exchange Chromatography.

    PubMed

    Vandenheuvel, Dieter; Rombouts, Sofie; Adriaenssens, Evelien M

    2018-01-01

    In bacteriophage research and therapy, most applications ask for highly purified phage suspensions. The standard technique for this is ultracentrifugation using cesium chloride gradients. This technique is cumbersome, elaborate and expensive. Moreover, it is unsuitable for the purification of large quantities of phage suspensions.The protocol described here, uses anion-exchange chromatography to bind phages to a stationary phase. This is done using an FLPC system, combined with Convective Interaction Media (CIM ® ) monoliths. Afterward, the column is washed to remove impurities from the CIM ® disk. By using a buffer solution with a high ionic strength, the phages are subsequently eluted from the column and collected. In this way phages can be efficiently purified and concentrated.This protocol can be used to determine the optimal buffers, stationary phase chemistry and elution conditions, as well as the maximal capacity and recovery of the columns.

  13. Hydrogen sulfide production by sulfate-reducing bacteria utilizing additives eluted from plastic resins.

    PubMed

    Tsuchida, Daisuke; Kajihara, Yusuke; Shimidzu, Nobuhiro; Hamamura, Kengo; Nagase, Makoto

    2011-06-01

    In the present study it was demonstrated that organic additives eluted from plastic resins could be utilized as substrates by sulfate-reducing bacteria. Two laboratory-scale experiments, a microcosm experiment and a leaching experiment, were conducted using polyvinyl chloride (PVC) as a model plastic resin. In the former experiment, the conversion of sulfate to sulfide was evident in microcosms that received plasticized PVC as the sole carbon source, but not in those that received PVC homopolymer. Additionally, dissolved organic carbon accumulated only in microcosms that received plasticized PVC, indicating that the dissolved organic carbon originated from additives. In the leaching experiment, phenol and bisphenol A were found in the leached solutions. These results suggest that the disposal of waste plastics in inert waste landfills may result in the production of H(2)S.

  14. Outcomes with various drug eluting or bare metal stents in patients with diabetes mellitus: mixed treatment comparison analysis of 22 844 patient years of follow-up from randomised trials

    PubMed Central

    Kumar, Sunil; Fusaro, Mario; Amoroso, Nicholas; Kirtane, Ajay J; Byrne, Robert A; Williams, David O; Slater, James; Cutlip, Donald E; Feit, Frederick

    2012-01-01

    Objectives To evaluate the efficacy and safety of currently used drug eluting stents compared with each other and compared with bare metal stents in patients with diabetes. Design Mixed treatment comparison meta-analysis. Data sources and study selection PubMed, Embase, and CENTRAL were searched for randomised clinical trials, until April 2012, of four durable polymer drug eluting stents (sirolimus eluting stents, paclitaxel eluting stents, everolimus eluting stents, and zotarolimus eluting stents) compared with each other or with bare metal stents for the treatment of de novo coronary lesions and enrolling at least 50 patients with diabetes. Primary outcomes Efficacy (target vessel revascularisation) and safety (death, myocardial infarction, stent thrombosis). Results From 42 trials with 22 844 patient years of follow-up, when compared with bare metal stents (reference rate ratio 1) all of the currently used drug eluting stents were associated with a significant reduction in target vessel revascularisation (37% to 69%), though the efficacy varied with the type of stent (everolimus eluting stents∼sirolimus eluting stents>paclitaxel eluting stents∼zotarolimus eluting stent>bare metal stents). There was about an 87% probability that everolimus eluting stents were the most efficacious compared with all others, though there were limited usable data for the zotarolimus eluting Resolute stent in patients with diabetes. Moreover, there was no increased risk of any safety outcome (including very late stent thrombosis) with any drug eluting stents compared with bare metal stents. There was about a 62% probability that the everolimus eluting stent was the safest stent for the outcome of “any” stent thrombosis. Conclusions Among patients with diabetes treated with coronary stents all currently available drug eluting stents were efficacious without compromising safety compared with bare metal stents. There were relative differences among the drug eluting stents, such that the everolimus eluting stent was the most efficacious and safe. PMID:22885395

  15. Operation, Maintenance and Performance Evaluation of the Potomac Estuary Experimental Water Treatment Plant. Appendix. Volume 1.

    DTIC Science & Technology

    1983-09-01

    Biochemical Screening A-i-12 Quantitative Determination of Viruses A-1-13 Virus Adsorption A-1-13 Elution A-1-13 Reconcentration A-1-13 Virus Assay A-I... VIRUSES VIRUS ADSORPTION " The virus concentration method was based on an adsorption/elution procedure described in the 14th edition of Standard...the replication process of one virus may be inhibited by another. If the inoculum contains few infective viruses , interference problems are of little

  16. Latanoprost-Eluting Contact Lenses in Glaucomatous Monkeys.

    PubMed

    Ciolino, Joseph B; Ross, Amy E; Tulsan, Rehka; Watts, Amy C; Wang, Rong-Fang; Zurakowski, David; Serle, Janet B; Kohane, Daniel S

    2016-10-01

    To assess the ability of latanoprost-eluting contact lenses to lower the intraocular pressure (IOP) of glaucomatous eyes of cynomolgus monkeys. Preclinical efficacy study of 3 treatment arms in a crossover design. Female cynomolgus monkeys with glaucoma induced in 1 eye by repeated argon laser trabeculoplasty. Latanoprost-eluting low-dose contact lenses (CLLO) and high-dose contact lenses (CLHI) were produced by encapsulating a thin latanoprost-polymer film within the periphery of a methafilcon hydrogel, which was lathed into a contact lens. We assessed the IOP-lowering effect of CLLO, CLHI, or daily latanoprost ophthalmic solution in the same monkeys. Each monkey consecutively received 1 week of continuous-wear CLLO, 3 weeks without treatment, 5 days of latanoprost drops, 3 weeks without treatment, and 1 week of continuous-wear CLHI. On 2 consecutive days before initiation of each study arm, the IOP was measured hourly over 7 consecutive hours to establish the baseline IOP. Two-tailed Student t tests and repeated-measures analysis of variance were used for statistical analysis. Intraocular pressure. Latanoprost ophthalmic solution resulted in IOP reduction of 5.4±1.0 mmHg on day 3 and peak IOP reduction of 6.6±1.3 mmHg on day 5. The CLLO reduced IOP by 6.3±1.0, 6.7±0.3, and 6.7±0.3 mmHg on days 3, 5, and 8, respectively. The CLHI lowered IOP by 10.5±1.4, 11.1±4.0, and 10.0±2.5 mmHg on days 3, 5, and 8, respectively. For the CLLO and CLHI, the IOP was statistically significantly reduced compared with the untreated baseline at most time points measured. The CLHI demonstrated greater IOP reduction than latanoprost ophthalmic solution on day 3 (P = 0.001) and day 5 (P = 0.015), and at several time points on day 8 (P < 0.05). Sustained delivery of latanoprost by contact lenses is at least as effective as delivery with daily latanoprost ophthalmic solution. More research is needed to determine the optimal continuous-release dose that would be well tolerated and maximally effective. Contact lens drug delivery may become an option for the treatment of glaucoma and a platform for ocular drug delivery. Copyright © 2016 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  17. Coupling process study of lipid production and mercury bioremediation by biomimetic mineralized microalgae.

    PubMed

    Peng, Yang; Deng, Aosong; Gong, Xun; Li, Xiaomin; Zhang, Yang

    2017-11-01

    Considering the high concentration of mercury in industrial wastewater, such as coal-fired power plants and gold mining wastewater, this research study investigated the coupling process of lipid production and mercury bioremediation using microalgae cells. Chlorella vulgaris modified by biomimetic mineralization. The cultivation was divided in two stages: a natural cultivation for 7days and 5days of Hg 2+ addition (10-100μg/L) for cultivation at different pH values (4-7) after inoculation. Next, the harvested cells were eluted, and lipid was extracted. The fluorescein diacetate (FDA) dye tests demonstrated that the mineralized layer enhanced the biological activity of microalgae cells in Hg 2+ contaminated media. Hg distribution tests showed that the Hg removal capacity of modified cells was increased from 62.85% to 94.74%, and 88.72% of eluted Hg 2+ concentration was observed in modified cells compared to 48.42% of raw cells, implying that more mercury was transferred from lipid and residuals into elutable forms. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Frontally eluted components procedure with thin layer chromatography as a mode of sample preparation for high performance liquid chromatography quantitation of acetaminophen in biological matrix.

    PubMed

    Klimek-Turek, A; Sikora, M; Rybicki, M; Dzido, T H

    2016-03-04

    A new concept of using thin-layer chromatography to sample preparation for the quantitative determination of solute/s followed by instrumental techniques is presented Thin-layer chromatography (TLC) is used to completely separate acetaminophen and its internal standard from other components (matrix) and to form a single spot/zone containing them at the solvent front position (after the final stage of the thin-layer chromatogram development). The location of the analytes and internal standard in the solvent front zone allows their easy extraction followed by quantitation by HPLC. The exctraction procedure of the solute/s and internal standard can proceed from whole solute frontal zone or its part without lowering in accuracy of quantitative analysis. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. A rapid and accurate approach for prediction of interactomes from co-elution data (PrInCE).

    PubMed

    Stacey, R Greg; Skinnider, Michael A; Scott, Nichollas E; Foster, Leonard J

    2017-10-23

    An organism's protein interactome, or complete network of protein-protein interactions, defines the protein complexes that drive cellular processes. Techniques for studying protein complexes have traditionally applied targeted strategies such as yeast two-hybrid or affinity purification-mass spectrometry to assess protein interactions. However, given the vast number of protein complexes, more scalable methods are necessary to accelerate interaction discovery and to construct whole interactomes. We recently developed a complementary technique based on the use of protein correlation profiling (PCP) and stable isotope labeling in amino acids in cell culture (SILAC) to assess chromatographic co-elution as evidence of interacting proteins. Importantly, PCP-SILAC is also capable of measuring protein interactions simultaneously under multiple biological conditions, allowing the detection of treatment-specific changes to an interactome. Given the uniqueness and high dimensionality of co-elution data, new tools are needed to compare protein elution profiles, control false discovery rates, and construct an accurate interactome. Here we describe a freely available bioinformatics pipeline, PrInCE, for the analysis of co-elution data. PrInCE is a modular, open-source library that is computationally inexpensive, able to use label and label-free data, and capable of detecting tens of thousands of protein-protein interactions. Using a machine learning approach, PrInCE offers greatly reduced run time, more predicted interactions at the same stringency, prediction of protein complexes, and greater ease of use over previous bioinformatics tools for co-elution data. PrInCE is implemented in Matlab (version R2017a). Source code and standalone executable programs for Windows and Mac OSX are available at https://github.com/fosterlab/PrInCE , where usage instructions can be found. An example dataset and output are also provided for testing purposes. PrInCE is the first fast and easy-to-use data analysis pipeline that predicts interactomes and protein complexes from co-elution data. PrInCE allows researchers without bioinformatics expertise to analyze high-throughput co-elution datasets.

  20. Temperature-assisted solute focusing with sequential trap/release zones in isocratic and gradient capillary liquid chromatography: Simulation and experiment

    PubMed Central

    Groskreutz, Stephen R.; Weber, Stephen G.

    2016-01-01

    In this work we characterize the development of a method to enhance temperature-assisted on-column solute focusing (TASF) called two-stage TASF. A new instrument was built to implement two-stage TASF consisting of a linear array of three independent, electronically controlled Peltier devices (thermoelectric coolers, TECs). Samples are loaded onto the chromatographic column with the first two TECs, TEC A and TEC B, cold. In the two-stage TASF approach TECs A and B are cooled during injection. TEC A is heated following sample loading. At some time following TEC A’s temperature rise, TEC B’s temperature is increased from the focusing temperature to a temperature matching that of TEC A. Injection bands are focused twice on-column, first on the initial TEC, e.g. single-stage TASF, then refocused on the second, cold TEC. Our goal is to understand the two-stage TASF approach in detail. We have developed a simple yet powerful digital simulation procedure to model the effect of changing temperature in the two focusing zones on retention, band shape and band spreading. The simulation can predict experimental chromatograms resulting from spatial and temporal temperature programs in combination with isocratic and solvent gradient elution. To assess the two-stage TASF method and the accuracy of the simulation well characterized solutes are needed. Thus, retention factors were measured at six temperatures (25–75 °C) at each of twelve mobile phases compositions (0.05–0.60 acetonitrile/water) for homologs of n-alkyl hydroxylbenzoate esters and n-alkyl p-hydroxyphenones. Simulations accurately reflect experimental results in showing that the two-stage approach improves separation quality. For example, two-stage TASF increased sensitivity for a low retention solute by a factor of 2.2 relative to single-stage TASF and 8.8 relative to isothermal conditions using isocratic elution. Gradient elution results for two-stage TASF were more encouraging. Application of two-stage TASF increased peak height for the least retained solute in the test mixture by a factor of 3.2 relative to single-stage TASF and 22.3 compared to isothermal conditions for an injection four-times the column volume. TASF improved resolution and increased peak capacity; for a 12-minute separation peak capacity increased from 75 under isothermal conditions to 146 using single-stage TASF, and 185 for two-stage TASF. PMID:27836226

  1. Temperature-assisted solute focusing with sequential trap/release zones in isocratic and gradient capillary liquid chromatography: Simulation and experiment.

    PubMed

    Groskreutz, Stephen R; Weber, Stephen G

    2016-11-25

    In this work we characterize the development of a method to enhance temperature-assisted on-column solute focusing (TASF) called two-stage TASF. A new instrument was built to implement two-stage TASF consisting of a linear array of three independent, electronically controlled Peltier devices (thermoelectric coolers, TECs). Samples are loaded onto the chromatographic column with the first two TECs, TEC A and TEC B, cold. In the two-stage TASF approach TECs A and B are cooled during injection. TEC A is heated following sample loading. At some time following TEC A's temperature rise, TEC B's temperature is increased from the focusing temperature to a temperature matching that of TEC A. Injection bands are focused twice on-column, first on the initial TEC, e.g. single-stage TASF, then refocused on the second, cold TEC. Our goal is to understand the two-stage TASF approach in detail. We have developed a simple yet powerful digital simulation procedure to model the effect of changing temperature in the two focusing zones on retention, band shape and band spreading. The simulation can predict experimental chromatograms resulting from spatial and temporal temperature programs in combination with isocratic and solvent gradient elution. To assess the two-stage TASF method and the accuracy of the simulation well characterized solutes are needed. Thus, retention factors were measured at six temperatures (25-75°C) at each of twelve mobile phases compositions (0.05-0.60 acetonitrile/water) for homologs of n-alkyl hydroxylbenzoate esters and n-alkyl p-hydroxyphenones. Simulations accurately reflect experimental results in showing that the two-stage approach improves separation quality. For example, two-stage TASF increased sensitivity for a low retention solute by a factor of 2.2 relative to single-stage TASF and 8.8 relative to isothermal conditions using isocratic elution. Gradient elution results for two-stage TASF were more encouraging. Application of two-stage TASF increased peak height for the least retained solute in the test mixture by a factor of 3.2 relative to single-stage TASF and 22.3 compared to isothermal conditions for an injection four-times the column volume. TASF improved resolution and increased peak capacity; for a 12-min separation peak capacity increased from 75 under isothermal conditions to 146 using single-stage TASF, and 185 for two-stage TASF. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. Use of Chelex-100 for selectively removing Y-90 from its parent Sr-90

    DOEpatents

    Huntley, Mark W.

    1996-01-01

    A method for selectively removing yttrium-90 from its parent strontium-90 contained in an environmental sample includes loading the sample onto a column containing a chelating ion-exchange resin capable of retaining yttrium-90; washing the column with a solution capable of removing strontium, calcium, and other contaminants from the yttrium-90 fraction retained on the column; removing excess acetate salts from the column; eluting yttrium-90 solution from the column and adjusting the pH of this solution to about 2.7; filtering the yttrium-90 solution and weighing this solution for gravimetric yield; and, counting the yttrium-90 containing solution with a radiological counter for a time sufficient to achieve the statistical accuracy desired. It is preferred that the chelating ion-exchange resin is a bidente ligand having the chemical name iminodiacetic acid mounted on a divinyl benzene substrate, converted from sodium form to ammonia form.

  3. Use of Chelex-100 for selectively removing Y-90 from its parent Sr-90

    DOEpatents

    Huntley, M.W.

    1996-02-27

    A method for selectively removing yttrium-90 from its parent strontium-90 contained in an environmental sample includes loading the sample onto a column containing a chelating ion-exchange resin capable of retaining yttrium-90; washing the column with a solution capable of removing strontium, calcium, and other contaminants from the yttrium-90 fraction retained on the column; removing excess acetate salts from the column; eluting yttrium-90 solution from the column and adjusting the pH of this solution to about 2.7; filtering the yttrium-90 solution and weighing this solution for gravimetric yield; and, counting the yttrium-90 containing solution with a radiological counter for a time sufficient to achieve the statistical accuracy desired. It is preferred that the chelating ion-exchange resin is a ligand having the chemical name iminodiacetic acid mounted on a divinyl benzene substrate, converted from sodium form to ammonia form.

  4. A novel convenient process to obtain a raw decaffeinated tea polyphenol fraction using a lignocellulose column.

    PubMed

    Sakanaka, Senji

    2003-05-07

    Lignocellulose prepared from sawdust was investigated for its potential application in obtaining a raw decaffeinated tea polyphenol fraction from tea extract. Tea polyphenols having gallate residues, namely, (-)epigallocatechin gallate (EGCg) and (-)epicatechin gallate (ECg), were adsorbed on the lignocellulose column, while caffeine was passed through it. Adsorbed polyphenols were eluted with 60% ethanol, and the elute was found to consist mainly of EGCg and ECg. The caffeine/EGCg ratio was 0.696 before lignocellulose column treatment, but it became 0.004 after the column treatment. These results suggest that the lignocellulose column provides a useful and convenient process of purification of tea polyphenol fraction accompanied by decaffeination.

  5. [Construction of NIRS-based process analytical system for production of salvianolic acid for injection and relative discussion].

    PubMed

    Zhang, Lei; Yue, Hong-Shui; Ju, Ai-Chun; Ye, Zheng-Liang

    2016-10-01

    Currently, near infrared spectroscopy (NIRS) has been considered as an efficient tool for achieving process analytical technology(PAT) in the manufacture of traditional Chinese medicine (TCM) products. In this article, the NIRS based process analytical system for the production of salvianolic acid for injection was introduced. The design of the process analytical system was described in detail, including the selection of monitored processes and testing mode, and potential risks that should be avoided. Moreover, the development of relative technologies was also presented, which contained the establishment of the monitoring methods for the elution of polyamide resin and macroporous resin chromatography processes, as well as the rapid analysis method for finished products. Based on author's experience of research and work, several issues in the application of NIRS to the process monitoring and control in TCM production were then raised, and some potential solutions were also discussed. The issues include building the technical team for process analytical system, the design of the process analytical system in the manufacture of TCM products, standardization of the NIRS-based analytical methods, and improving the management of process analytical system. Finally, the prospect for the application of NIRS in the TCM industry was put forward. Copyright© by the Chinese Pharmaceutical Association.

  6. Pilot-scale resin adsorption as a means to recover and fractionate apple polyphenols.

    PubMed

    Kammerer, Dietmar R; Carle, Reinhold; Stanley, Roger A; Saleh, Zaid S

    2010-06-09

    The purification and fractionation of phenolic compounds from crude plant extracts using a food-grade acrylic adsorbent were studied at pilot-plant scale. A diluted apple juice concentrate served as a model phenolic solution for column adsorption and desorption trials. Phenolic concentrations were evaluated photometrically using the Folin-Ciocalteu assay and by HPLC-DAD. Recovery rates were significantly affected by increasing phenolic concentrations of the feed solutions applied to the column. In contrast, the flow rate during column loading hardly influenced adsorption efficiency, whereas the temperature and pH value were shown to be crucial parameters determining both total phenolic recovery rates and the adsorption behavior of individual polyphenols. As expected, the eluent composition had the greatest impact on the desorption characteristics of both total and individual phenolic compounds. HPLC analyses revealed significantly different elution profiles of individual polyphenols depending on lipophilicity. This technique allows fractionation of crude plant phenolic extracts, thus providing the opportunity to design the functional properties of the resulting phenolic fractions selectively, and the present study delivers valuable information with regard to the adjustment of individual process parameters.

  7. In Vitro Toxicity and Activity of Dakin’s Solution, Mafenide Acetate, and Amphotericin B on Filamentous Fungi and Human Cells

    DTIC Science & Technology

    2013-08-01

    there are some data alluding to their ability to be used in implantable bone cement placed into wounds.27,28 In this study, we have shown that...2012;46:369 372. 27. Grimsrud C, Raven R, Fothergill AW, et al. The in vitro elution charac- teristics of antifungal-loaded PMMA bone cement and calcium

  8. Roughness Versus Charge Contributions to Representative Discrete Heterogeneity Underlying Mechanistic Prediction of Colloid Attachment, Detachment and Breakthrough-Elution Behavior Under Environmental Conditions.

    NASA Astrophysics Data System (ADS)

    Johnson, William; Farnsworth, Anna; Vanness, Kurt; Hilpert, Markus

    2017-04-01

    The key element of a mechanistic theory to predict colloid attachment in porous media under environmental conditions where colloid-collector repulsion exists (unfavorable conditions for attachment) is representation of the nano-scale surface heterogeneity (herein called discrete heterogeneity) that drives colloid attachment under unfavorable conditions. The observed modes of colloid attachment under unfavorable conditions emerge from simulations that incorporate discrete heterogeneity. Quantitative prediction of attachment (and detachment) requires capturing the sizes, spatial frequencies, and other properties of roughness asperities and charge heterodomains in discrete heterogeneity representations of different surfaces. The fact that a given discrete heterogeneity representation will interact differently with different-sized colloids as well as different ionic strengths for a given sized colloid allows backing out representative discrete heterogeneity via comparison of simulations to experiments performed across a range of colloid size, solution IS, and fluid velocity. This has been achieved on unfavorable smooth surfaces yielding quantitative prediction of attachment, and qualitative prediction of detachment in response to ionic strength or flow perturbations. Extending this treatment to rough surfaces, and representing the contributions of nanoscale roughness as well as charge heterogeneity is a focus of this talk. Another focus of this talk is the upscaling the pore scale simulations to produce contrasting breakthrough-elution behaviors at the continuum (column) scale that are observed, for example, for different-sized colloids, or same-sized colloids under different ionic strength conditions. The outcome of mechanistic pore scale simulations incorporating discrete heterogeneity and subsequent upscaling is that temporal processes such as blocking and ripening will emerge organically from these simulations, since these processes fundamentally stem from the limited sites available for attachment as represented in discrete heterogeneity.

  9. Gold nanoparticles: role of size and surface chemistry on blood protein adsorption

    NASA Astrophysics Data System (ADS)

    Benetti, F.; Fedel, M.; Minati, L.; Speranza, G.; Migliaresi, C.

    2013-06-01

    Material interaction with blood proteins is a critical issue, since it could influence the biological processes taking place in the body following implantation/injection. This is particularly important in the case of nanoparticles, where innovative properties, such as size and high surface to volume ratio can lead to a behavioral change with respect to bulk macroscopic materials and could be responsible for a potential risk for human health. The aim of this work was to compare gold nanoparticles (AuNP) and planar surfaces to study the role of surface curvature moving from the macro- to the nano-size in the process of blood protein adsorption. In the course of the study, different protocols were tested to optimize the analysis of protein adsorption on gold nanoparticles. AuNP with different size (10, 60 and 200 nm diameter) and surface coatings (citrate and polyethylene glycol) were carefully characterized. The stabilizing action of blood proteins adsorbed on AuNP was studied measuring the variation of size and solubility of the nanoparticles following incubation with single protein solutions (human serum albumin and fibrinogen) and whole blood plasma. In addition, we developed a method to elute proteins from AuNP to study the propensity of gold materials to adsorb plasma proteins in function of dimensional characteristics and surface chemistry. We showed a different efficacy of the various eluting media tested, proving that even the most aggressive agent cannot provide a complete detachment of the protein corona. Enhanced protein adsorption was evidenced on AuNP if compared to gold laminae (bare and PEGylated) used as macroscopic control, probably due to the superior AuNP surface reactivity.

  10. Exclusive nuclear location of estrogen receptors in Squalus testis.

    PubMed Central

    Callard, G V; Mak, P

    1985-01-01

    An estrogen (E)-binding molecule having both occupied and unoccupied sites is restricted to nuclear subfractions in the testis of the spiny dogfish (Squalus acanthias). We investigated the hypothesis that a species characterized by high body-fluid osmolarity (1010 mosM) has an estrogen receptor (ER) that binds to chromatin with high affinity and consequently resists redistribution during tissue processing. Although the steroid binding and sedimentation properties of the Squalus nuclear ER conformed to those of classical ER, its elution maximum from DNA-cellulose was unusually high (0.55 M NaCl). A tendency to adhere tightly to cell nuclei was reflected in the high salt concentration (0.43 M KCl) required to extract 50% of the receptors from the nuclear compartment during homogenization and in the stability of the nuclear ER population in the presence of high concentrations of a nonionic solute (urea) or increased buffer volume. Mixing and redistribution experiments showed that nuclear ER could be quantitatively and qualitatively measured in cytosolic extracts, ruling out the possibility that soluble receptors were being masked. Although Squalus oviduct ER was similar to that of testis, ER in the testis and liver of a related elasmobranch (Potamotrygon) that maintains osmotic equilibrium at 300 mosM more closely resembled mammalian ER in its elution maximum from DNA-cellulose (0.22 M NaCl) and cytosolic/nuclear ratios in low-salt buffers. We conclude that Squalus testis has a single ER pool located exclusively in the nuclear compartment. These observations support a revised concept of steroid action and further indicate that the chromatin affinity of the hormone-ER complex is an important factor in determining subfractional distribution during tissue processing. PMID:3856265

  11. Bioactivities and extraction optimization of crude polysaccharides from the fruits and leaves of Rubus chingii Hu.

    PubMed

    Zhang, Tian-Tian; Lu, Chuan-Li; Jiang, Jian-Guo; Wang, Min; Wang, Dong-Mei; Zhu, Wei

    2015-10-05

    Polysaccharides of Rubus chingii Hu fruit and leaf were extracted to compare their antioxidant, anti-inflammatory, and anticancer activities against breast cancer cells MCF-7 and liver cancer cells Bel-7402. Results showed that all the tested bioactivities of polysaccharides from leaf (L-Ps) were better than those of polysaccharides from fruit (F-Ps). Response surface methodology was then used to optimize the extraction conditions of polysaccharides from leaf. Additionally, polysaccharides from fruit and leaf were characterized and their contents of total sugars, proteins and uronic acid were compared. It was found that polysaccharides from fruit and leaf were similar in IR and UV absorption, but significantly different in contents of total sugars, protein and uronic acid. Their elution profiles of DEAE-Sepharose fast flow column were different too. The main peak of polysaccharides from fruit was eluted with 0.3 mol/l NaCl solution and the main peak of polysaccharides from leaf was eluted with deionized water. The differences between the two polysaccharides may be responsible for their differences in bioactivities. Further studies are required to explore their complete structural characteristics, structure-activity relationship and the mechanism of their activities. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. Rapid micro-scale proteolysis of proteins for MALDI-MS peptide mapping using immobilized trypsin

    NASA Astrophysics Data System (ADS)

    Gobom, Johan; Nordhoff, Eckhard; Ekman, Rolf; Roepstorff, Peter

    1997-12-01

    In this study we present a rapid method for tryptic digestion of proteins using micro-columns with enzyme immobilized on perfusion chromatography media. The performance of the method is exemplified with acyl-CoA-binding protein and reduced carbamidomethylated bovine serum albumin. The method proved to be significantly faster and yielded a better sequence coverage and an improved signal-to-noise ratio for the MALDI-MS peptide maps, compared to in-solution- and on-target digestion. Only a single sample transfer step is required, and therefore sample loss due to adsorption to surfaces is reduced, which is a critical issue when handling low picomole to femtomole amounts of proteins. An example is shown with on-column proteolytic digestion and subsequent elution of the digest into a reversed-phase micro-column. This is useful if the sample contains large amounts of salt or is too diluted for MALDI-MS analysis. Furthermore, by step-wise elution from the reversedphase column, a complex digest can be fractionated, which reduces signal suppression and facilitates data interpretation in the subsequent MS-analysis. The method also proved useful for consecutive digestions with enzymes of different cleavage specificity. This is exemplified with on-column tryptic digestion, followed by reversed-phase step-wise elution, and subsequent on-target V8 protease digestion.

  13. ELUTION OF URANIUM FROM RESIN

    DOEpatents

    McLEan, D.C.

    1959-03-10

    A method is described for eluting uranium from anion exchange resins so as to decrease vanadium and iron contamination and permit recycle of the major portion of the eluats after recovery of the uranium. Diminution of vanadium and iron contamination of the major portion of the uranium is accomplished by treating the anion exchange resin, which is saturated with uranium complex by adsorption from a sulfuric acid leach liquor from an ore bearing uranium, vanadium and iron, with one column volume of eluant prepared by passing chlorine into ammonium hydroxide until the chloride content is about 1 N and the pH is about 1. The resin is then eluted with 8 to 9 column volumes of 0.9 N ammonium chloride--0.1 N hydrochloric acid solution. The eluants are collected separately and treated with ammonia to precipitate ammonium diuranate which is filtered therefrom. The uranium salt from the first eluant is contaminated with the major portion of ths vanadium and iron and is reworked, while the uranium recovered from the second eluant is relatively free of the undesirable vanadium and irons. The filtrate from the first eluant portion is discarded. The filtrate from the second eluant portion may be recycled after adding hydrochloric acid to increase the chloride ion concentration and adjust the pH to about 1.

  14. Rapid column heating method for subcritical water chromatography.

    PubMed

    Fogwill, Michael O; Thurbide, Kevin B

    2007-01-19

    A novel resistive heating method is presented for subcritical water chromatography (SWC) that provides higher column heating rates than those conventionally obtained from temperature-programmed gas chromatography (GC) convection ovens. Since the polarity of water reduces dramatically with increasing temperature, SWC employs column heating to achieve gradient elution. As such, the rate at which the mobile phase is heated directly impacts the magnitude of such gradients applied in SWC. Data from the current study demonstrate that the maximum column heating rate attainable in a typical SWC apparatus (i.e. using a GC convection oven) is around 10 degrees C/min, even at instrument oven settings of over three times this value. Conversely, by wrapping the separation column with ceramic insulation and a resistively heated wire, the column heating rates are increased five-fold. As a result, elution times can be greatly decreased in SWC employing gradients. Separations of standard alcohol test mixtures demonstrate that the retention time of the latest eluting component decreases by 35 to 50% using the prototype method. Additionally, solute retention times in this mode deviate by less than 1% RSD over several trials, which compares very well to those obtained using a conventional GC convection oven. Results suggest that the developed method can be a useful alternative heating technique in SWC.

  15. Application of the powder of porous titanium carbide ceramics to a reusable adsorbent for environmental pollutants.

    PubMed

    Moriwaki, Hiroshi; Kitajima, Shiori; Shirai, Koji; Kiguchi, Kenji; Yamada, Osamu

    2011-01-30

    The aim of this study is to investigate the utilization of the powder of porous titanium carbide (TiC) ceramics as a novel adsorbent or a material for solid-phase extraction (SPE). The adsorption and elution of inorganic and organic pollutants, Pb(II), 2,4,6-trichlorophenol (TCP), perfluorooctane sulfonate (PFOS), and perfluorooctanoic acid (PFOA), to the material were evaluated. The cartridge packed with TiC ceramics powder was used for the extraction test of pollutants. The solution containing pollutants at 1.0 μg mL(-1) was passed through the TiC cartridge, and the substances were almost quantitatively removed. Furthermore, the pollutants retained in the cartridge were eluted with 3N HCl for Pb(II) and with methanol for organic pollutants. The recoveries of pollutants were over 80%. In addition, we used the TiC cartridge for the solid-phase extraction of water samples (500 mL each of the distilled water and the river water) by adding pollutants at determined concentrations. Every pollutant was adsorbed almost quantitatively, and eluted by 3N HCl or methanol. From these results, we concluded that the powder of porous TiC ceramics is a useful reusable adsorbent for the water cleanup and solid-phase extraction. Copyright © 2010 Elsevier B.V. All rights reserved.

  16. Incorporating high-pressure electroosmotic pump and a nano-flow gradient generator into a miniaturized liquid chromatographic system for peptide analysis.

    PubMed

    Chen, Apeng; Lynch, Kyle B; Wang, Xiaochun; Lu, Joann J; Gu, Congying; Liu, Shaorong

    2014-09-24

    We integrate a high-pressure electroosmotic pump (EOP), a nanoflow gradient generator, and a capillary column into a miniaturized liquid chromatographic system that can be directly coupled with a mass spectrometer for proteomic analysis. We have recently developed a low-cost high-pressure EOP capable of generating pressure of tens of thousands psi, ideal for uses in miniaturized HPLC. The pump worked smoothly when it was used for isocratic elutions. When it was used for gradient elutions, generating reproducible gradient profiles was challenging; because the pump rate fluctuated when the pump was used to pump high-content organic solvents. This presents an issue for separating proteins/peptides since high-content organic solvents are often utilized. In this work, we solve this problem by incorporating our high-pressure EOP with a nano-flow gradient generator so that the EOP needs only to pump an aqueous solution. With this combination, we develop a capillary-based nano-HPLC system capable of performing nano-flow gradient elution; the pump rate is stable, and the gradient profiles are reproducible and can be conveniently tuned. To demonstrate its utility, we couple it with either a UV absorbance detector or a mass spectrometer for peptide separations. Copyright © 2014. Published by Elsevier B.V.

  17. Prediction of the retention of s-triazines in reversed-phase high-performance liquid chromatography under linear gradient-elution conditions.

    PubMed

    D'Archivio, Angelo Antonio; Maggi, Maria Anna; Ruggieri, Fabrizio

    2014-08-01

    In this paper, a multilayer artificial neural network is used to model simultaneously the effect of solute structure and eluent concentration profile on the retention of s-triazines in reversed-phase high-performance liquid chromatography under linear gradient elution. The retention data of 24 triazines, including common herbicides and their metabolites, are collected under 13 different elution modes, covering the following experimental domain: starting acetonitrile volume fraction ranging between 40 and 60% and gradient slope ranging between 0 and 1% acetonitrile/min. The gradient parameters together with five selected molecular descriptors, identified by quantitative structure-retention relationship modelling applied to individual separation conditions, are the network inputs. Predictive performance of this model is evaluated on six external triazines and four unseen separation conditions. For comparison, retention of triazines is modelled by both quantitative structure-retention relationships and response surface methodology, which describe separately the effect of molecular structure and gradient parameters on the retention. Although applied to a wider variable domain, the network provides a performance comparable to that of the above "local" models and retention times of triazines are modelled with accuracy generally better than 7%. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Hydrodynamic chromatography of macromolecules using polymer monolithic columns.

    PubMed

    Edam, Rob; Eeltink, Sebastiaan; Vanhoutte, Dominique J D; Kok, Wim Th; Schoenmakers, Peter J

    2011-12-02

    The selectivity window of size-based separations of macromolecules was tailored by tuning the macropore size of polymer monolithic columns. Monolithic materials with pore sizes ranging between 75 nm and 1.2 μm were prepared in situ in large I.D. columns. The dominant separation mechanism was hydrodynamic chromatography in the flow-through pores. The calibration curves for synthetic polymers matched with the elution behavior by HDC separations in packed columns with 'analyte-to-pore' aspect ratios (λ) up to 0.2. For large-macropore monoliths, a deviation in retention behavior was observed for small polystyrene polymers (M(r)<20 kDa), which may be explained by a combined HDC-SEC mechanism for λ<0.02. The availability of monoliths with very narrow pore sizes allowed investigation of separations at high λ values. For high-molecular weight polymers (M(r)>300,000 Da) confined in narrow channels, the separation strongly depended on flow rate. Flow-rate dependent elution behavior was evaluated by calculation of Deborah numbers and confirmed to be outside the scope of classic shear deformation or slalom chromatography. Shear-induced forces acting on the periphery of coiled polymers in solution may be responsible for flow-rate dependent elution. Copyright © 2011 Elsevier B.V. All rights reserved.

  19. STUDY OF THE ADSORPTION ON AND DESORPTION FROM POLYSTYRENE-HUMAN SERUM ALBUMIN CONJUGATES OF RABBIT ANTI-HUMAN SERUM ALBUMIN ANTIBODIES HAVING DIFFERENT SPECIFICITIES

    PubMed Central

    Webb, Tom; Lapresle, Claude

    1961-01-01

    An insoluble specific adsorbent for anti-human serum albumin antibodies was prepared by coupling human serum albumin (H.S.A.) to polystyrene by azo bonds. Rabbit anti-H.S.A. immune serum was passed through a column of the adsorbent. It was shown that different volumes of the immune serum were required for the saturation of the different determinant groups of H.S.A. by their corresponding antibodies. The elution of the anti-H.S.A. antibodies adsorbed on the column was achieved by passing successively through the column an acetate buffer pH 3.0 and a solution of 0.1 N HCl in 0.15 M NaCl. The antibodies were eluted in three different fractions, each of which was composed of γ-globulins only. These three fractions contained different proportions of antibodies of different specificities. PMID:13783579

  20. Analytical modeling of drug dynamics induced by eluting stents in the coronary multi-layered curved domain.

    PubMed

    d'Errico, Michele; Sammarco, Paolo; Vairo, Giuseppe

    2015-09-01

    Pharmacokinetics induced by drug eluting stents (DES) in coronary walls is modeled by means of a one-dimensional multi-layered model, accounting for vessel curvature and non-homogeneous properties of the arterial tissues. The model includes diffusion mechanisms, advection effects related to plasma filtration through the walls, and bio-chemical drug reactions. A non-classical Sturm-Liouville problem with discontinuous coefficients is derived, whose closed-form analytical solution is obtained via an eigenfunction expansion. Soundness and consistency of the proposed approach are shown by numerical computations based on possible clinical treatments involving both hydrophilic and hydrophobic drugs. The influence of the main model parameters on drug delivery mechanisms is analyzed, highlighting the effects induced by vessel curvature and yielding comparative indications and useful insights into the concurring mechanisms governing the pharmacokinetics. Copyright © 2015. Published by Elsevier Inc.

  1. Patient-tailored Drug-eluting Stent Choice - A Solution for Patients with Diabetes: Proceedings of Two Satellite Symposia Held at EuroPCR in May 2015 in Paris.

    PubMed

    Mountfort, Katrina; Mehran, Roxana; Colombo, Antonio; Stella, Pieter; Romaguera, Rafael; Sardella, Gennaro

    2015-09-01

    Although second-generation drug-eluting stents (DES) have improved outcomes in percutaneous coronary interventions (PCIs), important unmet needs remain. Two symposia at EuroPCR 2015 focused on two challenging scenarios. First, patients with diabetes mellitus (DM) have generally inferior outcomes following PCI. The Cre8™ stent (manufactured by CID Spa, member of Alvimedica Group) has shown unique efficacy in subpopulations of patients with DM during clinical trials. A live case in a patient with diabetes illustrated the challenges of complex multivessel disease. Second, optimising stent selection towards devices that have demonstrated complete and early endothelialisation offers the potential to reduce the duration of dual antiplatelet therapy. The Cre8™ DES features a polymer-free platform and has been associated with low rates of in-stent thrombosis.

  2. On chip preconcentration and fluorescence labeling of model proteins by use of monolithic columns: device fabrication, optimization, and automation.

    PubMed

    Yang, Rui; Pagaduan, Jayson V; Yu, Ming; Woolley, Adam T

    2015-01-01

    Microfluidic systems with monolithic columns have been developed for preconcentration and on-chip labeling of model proteins. Monoliths were prepared in microchannels by photopolymerization, and their properties were optimized by varying the composition and concentration of the monomers to improve flow and extraction. On-chip labeling of proteins was achieved by driving solutions through the monolith by use of voltage then incubating fluorescent dye with protein retained on the monolith. Subsequently, the labeled proteins were eluted, by applying voltages to reservoirs on the microdevice, and then detected, by monitoring laser-induced fluorescence. Monoliths prepared from octyl methacrylate combine the best protein retention with the possibility of separate elution of unattached fluorescent label with 50% acetonitrile. Finally, automated on-chip extraction and fluorescence labeling of a model protein were successfully demonstrated. This method involves facile sample pretreatment, and therefore has potential for production of integrated bioanalysis microchips.

  3. Capillary electrochromatography and preconcentration of neutral compounds on poly(dimethylsiloxane) microchips.

    PubMed

    Ro, Kyung Won; Chang, Woo-Jin; Kim, Ho; Koo, Yoon-Mo; Hahn, Jong Hoon

    2003-09-01

    Capillary electrochromatography (CEC) and preconcentration of neutral compounds have been realized on poly(dimethylsiloxane) (PDMS) microchips. The channels are coated with polyelectrolyte multilayers to avoid absorption of hydrophobic analytes into PDMS. The structures of a microchip include an injector and a bead chamber with integrated frits, where the particles of the stationary phase are completely retained. Dimensions of the frit structures are 25 micro mx20 micro m, and the space between the structures is 3 micro m. A neutral compound, BODIPY, that is strongly absorbed into native PDMS, is successfully and selectively retained on octadecylsilane-coated silica beads in the bead chamber with a concentration enhancement of up to 100 times and eluted with elution buffer solution containing 70% acetonitrile. Preconcentrations and CEC separations of coumarins have been conducted with the same device and achieved complete separations in less than 50 s.

  4. Continuous biosorption of Pb/Cu and Pb/Cd in fixed-bed column using algae Gelidium and granulated agar extraction algal waste.

    PubMed

    Vilar, Vítor J P; Loureiro, José M; Botelho, Cidália M S; Boaventura, Rui A R

    2008-06-15

    Continuous metal ions biosorption from Pb/Cu and Pb/Cd solutions onto seaweed Gelidium sesquipedale and a composite material prepared from an industrial algal waste was performed in a packed bed column. A binary Langmuir equation describes well the equilibrium data and indicates a good adsorption capacity. In the sorption process, Cd and Cu break through the column faster than Pb due to its lower affinity for the biosorbent. An overshoot in the outlet Cd concentration was observed and explained by competitive adsorption between Pb and Cd, whereby the higher Pb affinity for the biosorbent displaces bound Cd ions. A small overshoot happens for Cu adsorption in the presence of Pb ions. Desorption using 0.1 M HNO3 as eluant, was 100% effective. A mass transfer model for the adsorption and desorption processes, considering an external and intraparticle film resistance, adequately simulates the column performance. A binary Langmuir equation was used to describe equilibrium for the saturation process and a mass action law for the desorption process. Elution process is defined as an ion exchange mechanism, between protons and metal ions.

  5. Highly Efficient Interception and Precipitation of Uranium(VI) from Aqueous Solution by Iron-Electrocoagulation Combined with Cooperative Chelation by Organic Ligands.

    PubMed

    Li, Peng; Zhun, Bao; Wang, Xuegang; Liao, PingPing; Wang, Guanghui; Wang, Lizhang; Guo, Yadan; Zhang, Weimin

    2017-12-19

    A new strategy combining iron-electrocoagulation and organic ligands (OGLs) cooperative chelation was proposed to screen and precipitate low concentrations (0-18.52 μmol/L) of uranium contaminant in aqueous solution. We hypothesized that OGLs with amino, hydroxyl, and carboxyl groups hydrophobically/hydrophilically would realize precuring of uranyl ion at pH < 3.0, and the following iron-electrocoagulation would achieve faster and more efficient uranium precipitation. Experimentally, the strategy demonstrated highly efficient uranium(VI) precipitation efficiency, especially with hydrophilic macromolecular OGLs. The uranium removal efficiency at optimized experimental condition reached 99.65%. The decrease of zeta potential and the lattice enwrapping between U-OGLs chelates and flocculation precursor were ascribed to the enhanced uranium precipitation activity. Uranium was precipitated as oxides of U(VI) or higher valences that were easily captured in aggregated micelles under low operation current potential. The actual uranium tailing wastewater was treated, and a satisfied uranium removal efficiency of 99.02% was discovered. After elution of the precipitated flocs, a concentrated uranium solution (up to 106.52 μmol/L) with very few other metallic impurities was obtained. Therefore, the proposed strategy could remove uranium and concentrate it concurrently. This work could provide new insights into the purification and recovery of uranium from aqueous solutions in a cost-effective and environmentally friendly process.

  6. Ultra-High Performance Liquid Chromatography (UHPLC) Method for the Determination of Limonene in Sweet Orange (Citrus sinensis) Oil: Implications for Limonene Stability.

    PubMed

    Bernart, Matthew W

    2015-01-01

    The citrus-derived bioactive monoterpene limonene is an important industrial commodity and fragrance constituent. An RP isocratic elution C18 ultra-HPLC (UHPLC) method using a superficially porous stationary phase and photodiode array (PDA) detector has been developed for determining the limonene content of sweet orange (Citrus sinensis) oil. The method is fast with a cycle time of 1.2 min, linear, precise, accurate, specific, and stability indicating, and it satisfies U.S. Pharmacopeia suitability parameters. The method may be useful in its present form for limonene processing, or modified for research on more polar compounds of the terpenome. A forced-degradation experiment showed that limonene is degraded by heat in hydro-ethanolic solution. PDA detection facilitates classification of minor components of the essential oil, including β-myrcene.

  7. Synthesis and chromatographic characterization of dextran-coated zirconia high-performance liquid chromatographic stationary phases.

    PubMed

    Dunlap, C J; Carr, P W

    1996-10-11

    Porous zirconia particles made by the oil emulsion (OE) method and the polymerization-induced colloid aggregation (PICA) method have been coated with a small, carboxymethylated (approximately 5%) dextran polymer and crosslinked in place. The parameters of the coating process (dextran concentration, adsorption time and crosslinker concentration) have all been examined and an optimum value for each determined. The coated and uncoated materials were characterized by nitrogen sorptometry and size-exclusion chromatography (SEC) using solutes (polystyrenes and dextrans) of well-defined molecular masses. Nitrogen sorptometry results show that the PICA material has a much lower pore volume and smaller pore diameter than do the OE materials. Despite this, the elution volumes of the SEC probes change very little upon polymer coating the PICA material while the OE material shows a very large change upon coating.

  8. Multi-walled carbon nanotubes as solid-phase extraction sorbents for simultaneous determination of type A trichothecenes in maize, wheat and rice by ultra-high performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Dong, Maofeng; Si, Wenshuai; Jiang, Keqiu; Nie, Dongxia; Wu, Yongjiang; Zhao, Zhihui; De Saeger, Sarah; Han, Zheng

    2015-12-04

    A solid-phase extraction (SPE) procedure using multi-walled carbon nanotubes (MWCNTs) as sorbents coupled with ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) was developed for simultaneous determination of four type A trichothecenes in maize, wheat and rice for the first time. Several key parameters including the composition of sample loading solutions, washing and elution solvents were thoroughly investigated to achieve optimal SPE recoveries and efficiency. Performance of the MWCNTs materials was significantly affected by pH, and after optimization, n-hexane and 5% methanol aqueous solution as the washing solutions and methanol containing 1% formic acid as the elution solvent presented an excellent purification efficiency for the four targets in the different matrices. The method was validated by determining the linearity (R(2)≥0.992), recovery (73.4-113.7%), precision (1.2-17.1%) and sensitivity (limit of quantification in the range of 0.02-0.10μg/kg), and was further applied for simultaneous determination of type A trichothecenes in 30 samples. Although low contamination levels of type A trichothecenes in wheat, maize and rice were observed revealing mitigated risks to consumers in Shanghai, China, the developed method has proven to be a valuable tool for type A trichothecenes monitoring in complex crop matrices. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Characteristics of SnO2-based 68Ge/68Ga generator and aspects of radiolabelling DOTA-peptides.

    PubMed

    de Blois, Erik; Sze Chan, Ho; Naidoo, Clive; Prince, Deidre; Krenning, Eric P; Breeman, Wouter A P

    2011-02-01

    PET scintigraphy with (68)Ga-labelled analogs is of increasing interest in Nuclear Medicine and performed all over the world. Here we report the characteristics of the eluate of SnO(2)-based (68)Ge/(68)Ga generators prepared by iThemba LABS (Somerset West, South Africa). Three purification and concentration techniques of the eluate for labelling DOTA-TATE and concordant SPE purifications were investigated. Characteristics of 4 SnO(2)-based generators (range 0.4-1 GBq (68)Ga in the eluate) and several concentration techniques of the eluate (HCl) were evaluated. The elution profiles of SnO(2)-based (68)Ge/(68)Ga generators were monitored, while [HCl] of the eluens was varied from 0.3-1.0 M. Metal ions and sterility of the eluate were determined by ICP. Fractionated elution and concentration of the (68)Ga eluate were performed using anion and cation exchange. Concentrated (68)Ga eluate, using all three concentration techniques, was used for labelling of DOTA-TATE. (68)Ga-DOTA-TATE-containing solution was purified and RNP increased by SPE, therefore also 11 commercially available SPE columns were investigated. The amount of elutable (68)Ga activity varies when the concentration of the eluens, HCl, was varied, while (68)Ge activity remains virtually constant. SnO(2)-based (68)Ge/(68)Ga generator elutes at 0.6 M HCl >100% of the (68)Ga activity at calibration time and ±75% after 300 days. Eluate at discharge was sterile and Endotoxins were <0.5 EU/mL, RNP was always <0.01%. Metal ions in the eluate were <10 ppm (in total). Highest desorption for anion purification was obtained with the 30 mg Oasis WAX column (>80%). Highest desorption for cation purification was obtained using a solution containing 90% acetone at increasing molarity of HCl, resulted in a (68)Ga desorption of 68±8%. With all (68)Ge/(68)Ga generators and for all 3 purification methods a SA up to 50 MBq/nmol with >95% incorporation (ITLC) and RCP (radiochemical purity) by HPLC ±90% could be achieved. Purification and concentration of the eluate with anion exchange has the benefit of more elutable (68)Ga with 1 M HCl as eluens. The additional washing step of the anion column with NaCl and ethanol, resulted in a lower and less variable [H(+)] in the eluate, and, as a result the pH in the reaction vial is better controlled, more constant, and less addition of buffer is required and concordant smaller reaction volumes. Desorption of (68)Ga-DOTA-TATE of SPE columns varied, highest desorption was obtained with Baker C(18) 100 mg (84%). Purification of (68)Ga-DOTA-TATE by SPE resulted in an RNP of <10(-4)%. Eluate of SnO(2)-based (68)Ge/(68)Ga generator, either by fractionated elution as by ion exchange can be used for labelling DOTA-peptides with (68)Ga at a SA of 50 MBq/nmol at >95% incorporation and a RCP of ±90%. SPE columns are very effective to increase RNP. Copyright © 2010 Elsevier Ltd. All rights reserved.

  10. Atrial natriuretic-like peptide and its prohormone within metasequoia.

    PubMed

    Yang, Q; Gower, W R; Li, C; Chen, P; Vesely, D L

    1999-07-01

    Metasequoia glyptostroboides was one of the dominant conifers in North America, Asia, and Europe for more than 100 million years since the late Cretaceous Albian Age, but Quaternary glaciations drove the Metasequoia population to apparent extinction. A small pocket of Metasequoia, however, was found in central China in the 1940s representing the only surviving population of this "living fossil" species. Atrial natriuretic peptide, a 28-amino-acid peptide hormone that causes sodium and water excretion in animals, has been found to be part of the first peptide hormonal system in lower plants. The existence of this hormonal system has never been examined within trees of any genus. High-performance gel permeation chromatography of the leaves and stems (i.e., branches) of Metasequoia followed by atrial natriuretic peptide radioimmunoassay revealed an ANP-like peptide and its prohormone (i.e., approximately 13,000 mol wt) were present in both leaves and stems of this conifer. The elution profile of ANP-like peptide in stems of Metasequoia had a shoulder to the left of where pure synthetic ANP elutes suggesting the possibility of a slightly larger peptide eluting within this shoulder secondary to alternate processing of the ANP-like prohormone and similar to what occurs with the kidney of animals. The elution profile of ANP-like peptide in the leaves of Metasequoia revealed two peaks; one where ANP elutes and a second peak suggesting a smaller peptide that has been metabolically processed. The presence of the ANP-like prohormone strongly suggests that ANP-like gene expression is occurring in both leaves and stems of Metasequoia since this prohormone is the gene product of this hormonal system. The presence of the ANP-like hormonal system in trees implies that this hormonal system may have been present early in land plant evolution to allow trees to reach heights of greater than 30 feet where a water flow-enhancing substance is absolutely necessary for water flow to occur to these heights.

  11. Can we model solute transfer in heterogeneous soils with MIM model?

    NASA Astrophysics Data System (ADS)

    Ben Slimene, Erij; Lassabatere, Laurent; Winiarski, Thierry; Gourdon, Remy

    2017-04-01

    The fate of pollutants in the vadose zone must be understood, in particular, underneath infiltration basins for an optimum management of these plants. Stormwaters carry pollutants (heavy metals, organics, emerging pollutant like nanoparticles, etc.) and thus constitute a risk for groundwater and soil quality. Most infiltration basins are settled over highly permeable soils that exhibit a strong lithological heterogeneity. The impact of such lithological heterogeneity on flow and solute transfer has already been questioned. Previous studies have already proved that lithological heterogeneity was prone to the establishment of preferential flows. In more details, the concomitance of several materials with contrasting hydraulic properties induces funneled flow at the interfaces between less permeable and more permeable lithofacies. Solutes are then carried by water fluxes quickly along preferential flow pathways and have restricted access to zones far from these pathways. It can clearly be imagined that such pattern could be modeled by a MIM model postulating water fraction into two fractions, one mobile and the other immobile, with solute transport by convection and dispersion in mobile water fraction and solute diffusion at the interface between mobile and immobile water fractions. The application of MIM approach to the case of solute transport in strongly heterogeneous soils may be quite advantageous: simplification of the problem, fewer parameters, ease of modeling, numerical computation, gain in computation time, etc. However, such consistency has never been investigated in details. In this paper, we focus on the possibility to model solute transport in a strongly heterogeneous deposit using MIM model. The deposit has been the subject of intensive campaigns of characterization of its lithology and the hydraulic and hydrodispersive properties of its lithofacies. Numerical computations were performed for a section of deposit 13.5 m wide and 2.5 m deep. Numerical results clearly showed the establishment of preferential flows with funneling mostly under unsaturated conditions. Solute elution at 2.5 m depth was characterized and discussed as a function of solute reactivity. Solutes breakthrough curves show clear evidence of MIM like pattern. In this paper, we clearly demonstrate that MIM model accurately reproduces solute elution at 2.5m depths but also at different depths. MIM approach accuracy is ensured provided that related parameters are optimized as a function of depth, hydric and hydraulic conditions and the contrast in hydraulic parameters of the lithofacies that constitute the deposit.

  12. Effect of tritium on corrosion behavior of chromium in 0.01 N sulfuric acid solution

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oyaidzu, M.; Isobe, K.; Hayashi, T.

    The effects of tritium on the corrosion behavior of chromium in 0.01 N sulfuric solution have been investigated in the present study. Electrochemical experiments have been carried our for pure chromium. At first, the concentration dependence of sulfuric acid solution on anodic polarization behavior of chromium was experimented, resulting in that 0.01 N one was found appropriate. The dependence of both dissolved oxygen and tritium concentration on anodic behavior of chromium were performed. It was found from that the self-passivation of chromium induced by dissolved oxygen was inhibited in tritiated solution resulting in the enhancement of the corrosion. As amore » consequence it is highly likely that the elution of chromium by highly oxidative radiolysis products would explain the passivation inhibitory effect of SUS304 stainless steel observed in tritiated solutions.« less

  13. A simple elution strategy for biotinylated proteins bound to streptavidin conjugated beads using excess biotin and heat.

    PubMed

    Cheah, Joleen S; Yamada, Soichiro

    2017-12-02

    Protein-protein interactions are the molecular basis of cell signaling. Recently, proximity based biotin identification (BioID) has emerged as an alternative approach to traditional co-immunoprecipitation. In this protocol, a mutant biotin ligase promiscuously labels proximal binding partners with biotin, and resulting biotinylated proteins are purified using streptavidin conjugated beads. This approach does not require preservation of protein complexes in vitro, making it an ideal approach to identify transient or weak protein complexes. However, due to the high affinity bond between streptavidin and biotin, elution of biotinylated proteins from streptavidin conjugated beads requires harsh denaturing conditions, which are often incompatible with downstream processing. To effectively release biotinylated proteins bound to streptavidin conjugated beads, we designed a series of experiments to determine optimal binding and elution conditions. Interestingly, the concentrations of SDS and IGEPAL-CA630 during the incubation with streptavidin conjugated beads were the key to effective elution of biotinylated proteins using excess biotin and heating. This protocol provides an alternative method to isolate biotinylated proteins from streptavidin conjugated beads that is suitable for further downstream analysis. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Highly efficient capture and harvest of circulating tumor cells on a microfluidic chip integrated with herringbone and micropost arrays.

    PubMed

    Xue, Peng; Wu, Yafeng; Guo, Jinhong; Kang, Yuejun

    2015-04-01

    Circulating tumor cells (CTCs), which are derived from primary tumor site and transported to distant organs, are considered as the major cause of metastasis. So far, various techniques have been applied for CTC isolation and enumeration. However, there exists great demand to improve the sensitivity of CTC capture, and it remains challenging to elute the cells efficiently from device for further biomolecular and cellular analyses. In this study, we fabricate a dual functional chip integrated with herringbone structure and micropost array to achieve CTC capture and elution through EpCAM-based immunoreaction. Hep3B tumor cell line is selected as the model of CTCs for processing using this device. The results demonstrate that the capture limit of Hep3B cells can reach up to 10 cells (per mL of sample volume) with capture efficiency of 80% on average. Moreover, the elution rate of the captured Hep3B cells can reach up to 69.4% on average for cell number ranging from 1 to 100. These results demonstrate that this device exhibits dual functions with considerably high capture rate and elution rate, indicating its promising capability for cancer diagnosis and therapeutics.

  15. Metal ion removal from aqueous solution using physic seed hull.

    PubMed

    Mohammad, Masita; Maitra, Saikat; Ahmad, Naveed; Bustam, Azmi; Sen, T K; Dutta, Binay K

    2010-07-15

    The potential of physic seed hull (PSH), Jantropha curcas L. as an adsorbent for the removal of Cd(2+) and Zn(2+) metal ions from aqueous solution has been investigated. It has been found that the amount of adsorption for both Cd(2+) and Zn(2+) increased with the increase in initial metal ions concentration, contact time, temperature, adsorbent dosage and the solution pH (in acidic range), but decreased with the increase in the particle size of the adsorbent. The adsorption process for both metal ions on PSH consists of three stages-a rapid initial adsorption followed by a period of slower uptake of metal ions and virtually no uptake at the final stage. The kinetics of metal ions adsorption on PSH followed a pseudo-second-order model. The adsorption equilibrium data were fitted in the three adsorption isotherms-Freundlich, Langmuir and Dubinin-Radushkevich isotherms. The data best fit in the Langmuir isotherm indication monolayer chemisorption of the metal ions. The adsorption capacity of PSH for both Zn(2+) and Cd(2+) was found to be comparable with other available adsorbents. About 36-47% of the adsorbed metal could be leached out of the loaded PSH using 0.1M HCl as the eluting medium. 2010 Elsevier B.V. All rights reserved.

  16. Process for preparing radiopharmaceuticals

    DOEpatents

    Barak, Morton; Winchell, Harry S.

    1977-01-04

    A process for the preparation of technetium-99m labeled pharmaceuticals is disclosed. The process comprises initially isolating technetium-99m pertechnetate by adsorption upon an adsorbent packing in a chromatographic column. The technetium-99m is then eluted from the packing with a biological compound to form a radiopharmaceutical.

  17. Development of "ultrasound-assisted dynamic extraction" and its combination with CCC and CPC for simultaneous extraction and isolation of phytochemicals.

    PubMed

    Zhang, Yuchi; Liu, Chunming; Li, Jing; Qi, Yanjuan; Li, Yuchun; Li, Sainan

    2015-09-01

    A new method for the extraction of medicinal herbs termed ultrasonic-assisted dynamic extraction (UADE) was designed and evaluated. This technique was coupled with counter-current chromatography (CCC) and centrifugal partition chromatography (CPC) and then applied to the continuous extraction and online isolation of chemical constituents from Paeonia lactiflora Pall (white peony) roots. The mechanical parameters, including the pitch and diameter of the shaft, were optimized by means of mathematical modeling. Furthermore, the configuration and mechanism of online UADE coupled with CCC and CPC were elaborated. The stationary phases of the two-phase solvent systems from CCC and CPC were utilized as the UADE solution. The extraction solution was pumped into the sample loop and then introduced into the CCC column; the target compounds were eluted with the lower aqueous phase of the two-phase solvent system. During the CCC separation, the extraction solution was continuously fed in the sample loop by turning the ten-port valve; the extraction solution was then pumped into the CPC column and eluted by the mobile phase of the two-phase solvent system mentioned above. When the first cycle of the UADE/CCC/CPC was completed, the second cycle experiment could be carried out, and so on. Four target compounds (albiflorin, benzoylpaeoniflorin, paeoniflorin, and galloylpaeoniflorin) with purities above 94.96% were successfully extracted and isolated online using the two-phase solvent system comprising ethyl acetate-n-butanol-ethanol-water (1:3.5:2:4.5, v/v/v/v). Compared with conventional extraction methods, the instrumental setup of the present method offers the advantages of automation and systematic extraction and isolation of natural products. Crown Copyright © 2015. Published by Elsevier B.V. All rights reserved.

  18. Copper desorption from Gelidium algal biomass.

    PubMed

    Vilar, Vítor J P; Botelho, Cidália M S; Boaventura, Rui A R

    2007-04-01

    Desorption of divalent copper from marine algae Gelidium sesquipedale, an algal waste (from agar extraction industry) and a composite material (the algal waste immobilized in polyacrylonitrile) was studied in a batch system. Copper ions were first adsorbed until saturation and then desorbed by HNO(3) and Na(2)EDTA solutions. Elution efficiency using HNO(3) increases as pH decreases. At pH=1, for a solid to liquid ratio S/L=4gl(-1), elution efficiency was 97%, 95% and 88%, the stoichiometric coefficient for the ionic exchange, 0.70+/-0.02, 0.73+/-0.05 and 0.76+/-0.06 and the selectivity coefficient, 0.93+/-0.07, 1.0+/-0.3 and 1.1+/-0.3, respectively, for algae Gelidium, algal waste and composite material. Complexation of copper ions by EDTA occurs in a molar proportion of 1:1 and the elution efficiency increases with EDTA concentration. For concentrations of 1.4, 0.88 and 0.57 mmoll(-1), the elution efficiency for S/L=4gl(-1), was 91%, 86% and 78%, respectively, for algae Gelidium, algal waste and composite material. The S/L ratio, in the range 1-20gl(-1), has little influence on copper recovery by using 0.1M HNO(3). Desorption kinetics was very fast for all biosorbents. Kinetic data using HNO(3) as eluant were well described by the mass transfer model, considering the average metal concentration in the solid phase and the equilibrium relationship given by the mass action law. The homogeneous diffusion coefficient varied between 1.0 x 10(-7)cm(2)s(-1) for algae Gelidium and 3.0 x 10(-7)cm(2)s(-1) for the composite material.

  19. Surface charge fine tuning of reversed-phase/weak anion-exchange type mixed-mode stationary phases for milder elution conditions.

    PubMed

    Zimmermann, Aleksandra; Horak, Jeannie; Sánchez-Muñoz, Orlando L; Lämmerhofer, Michael

    2015-08-28

    A series of new mixed-mode reversed-phase/weak anion-exchange (RP/WAX) phases have been synthesized by immobilization of N-undecenyl-3-α-aminotropane onto thiol-modified silica gel by thiol-ene click chemistry and subsequent introduction of acidic thiol-endcapping functionalities of different type and surface densities. Click chemistry allowed to adjust a controlled surface concentration of the RP/WAX ligand in such a way that a sufficient quantity of residual thiols remained unmodified which have been capped by thiol click with either 3-butenoic acid or allylsulfonic acid as co-ligands. In another embodiment, performic acid oxidation of N-undecenyl-3-α-aminotropane-derivatized thiol-modified silica gave a RP/WAX phase with high density of sulfonic acid end-capping groups. ζ-Potential determinations confirmed the fine-tuned pI of these mixed-mode stationary phases which was shifted from 9.5 to 8.2, 7.8, and 6.5 with 3-butenoic acid and allylsulfonic acid end-capping as well as performic acid oxidation. For acidic solutes, the co-ionic endcapping leads to strongly reduced retention times and clearly allowed elution of these analytes under lower ionic strength thus milder elution conditions. In spite of the acidic endcapping, the new mixed-mode phases maintained their hydrophobic and anion-exchange selectivity as well as their multimodal nature featuring RP and HILIC elution domains at acetonitrile percentages below and above 50%, respectively. Column classification by principal component analysis of an extended retention map in comparison to a set of polar commercial and in-house synthesized stationary phases confirmed complementarity of the new mixed-mode phases with respect to HILIC, polar RP, amino and commercial mixed-mode phases. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. Inductively coupled plasma mass spectrometry study of the retention behavior of arsenic species on various solid phase extraction cartridges and its application in arsenic speciation

    NASA Astrophysics Data System (ADS)

    Yu, Chunhai; Cai, Qiantao; Guo, Zhong-Xian; Yang, Zhaoguang; Khoo, Soo Beng

    2003-07-01

    Inductively coupled plasma mass spectrometry (ICP-MS) was used to investigate the retention behavior of arsenite, arsenate, monomethylarsonic acid (MMA), dimethylarsinic acid (DMA), arsenobetaine (AsB), arsenocholine (AsC), trimethylarsine oxide (TMAO) and tetramethylarsonium ion (TMAI) on various silica-based solid phase extraction (SPE) cartridges. A method for arsenic speciation is then developed on the basis of selective SPE separation of arsenic species and highly sensitive ICP-MS detection. Factors affecting the retention and elution of arsenic species were examined. Results showed that the retention of arsenic species depended on the chemical characteristics of arsenic species and the types of sorbent materials. Change of pH in the range of 2.0-9.0 did not show significant effects on the retention of DMA, AsB, AsC, TMAI and TMAO on an ethylbenzene sulfonic acid-based strong cation exchange (SCX-3) cartridge. pH also did not influence the retention of AsB, AsC, TMAI and TMAO on a mixed-mode (M-M) cartridge containing non-polar, strong cation exchange and strong anion exchange (SAX) functional groups. However, the retentions of As(V) and MMA on the SAX and the M-M cartridge changed with pH. As(V) and MMA were completely retained on the SAX cartridge and sequentially selectively eluted with 1.0 mol l -1 acetic acid (for MMA). DMA, AsB, AsC, TMAI and TMAO were completely retained on the SCX-3 cartridge and sequentially selectively eluted with 1.0 mol l -1 HNO 3 (for DMA). As(V), MMA, AsB, AsC, TMAI and TMAO were completely retained on the M-M cartridge. As(III) was not retained on either cartridge and remained in solution. Arsenic species in solution and those eluted from the cartridges were subsequently determined by ICP-MS. A detection limit of 8 ng l -1 arsenic in water sample was obtained. This method was successfully applied to arsenic speciation in various sources of water samples (drinking water, waste water, raw water, etc.) and US National Institute of Standards and Technology standard reference materials with good precision and accuracy.

  1. Characterization of polypropylene–polyethylene blends by temperature rising elution and crystallization analysis fractionation

    PubMed Central

    del Hierro, Pilar

    2010-01-01

    The introduction of single-site catalysts in the polyolefins industry opens new routes to design resins with improved performance through multicatalyst-multireactor processes. Physical combination of various polyolefin types in a secondary extrusion process is also a common practice to achieve new products with improved properties. The new resins have complex structures, especially in terms of composition distribution, and their characterization is not always an easy task. Techniques like temperature rising elution fractionation (TREF) or crystallization analysis fractionation (CRYSTAF) are currently used to characterize the composition distribution of these resins. It has been shown that certain combinations of polyolefins may result in equivocal results if only TREF or CRYSTAF is used separately for their characterization. PMID:20730530

  2. Improved method for concentration of Giardia, Cryptosporidium, and poliovirus from water.

    PubMed

    Watt, Pamela M; Johnson, Dana C; Gerba, Charles P

    2002-03-01

    Methods for the concentration of enteric viruses and the protozoan parasites, Giardia and Cryptosporidium, from drinking water currently require the use of two different types of filters. Electropositive or electronegative microporous filters (0.2-0.45 microm nominal porosity) are used for the collection of enteroviruses, while polypropylene spun-fiber filters (1 microm porosity) and small pleated cartridge filters are used for the collection of protozoan parasites from water. Since the filter mechanically traps the protozoa by size exclusion, a microporous filter with an appropriately small nominal porosity could possibly be used for co-collection of both protozoa and enteroviruses. This study compared the concentration efficiencies of a polypropylene fiber cartridge (DPPPY) filter and two different microporous filters (Filterite and IMDS) with poliovirus (type 1), with respect to their ability to concentrate Giardia and Cryptosporidium from water. Giardia cysts and Cryptosporidium oocysts were added to 4001 of either tap water or tertiary treated wastewater and passed through the test filter. The protozoa were eluted from the polypropylene filter by hand-washing in a detergent solution. Viruses and protozoa were eluted from the microporous filter by two consecutive back-washes with a 1.5% beef extract, 0.1% Tween 80 solution. The eluent was then centrifuged to remove the parasites and the supernatant assayed for viruses. The overall efficiency was greater for the Filterite filter (40.4% for Giardia; 36.6% for Cryptosporidium) when compared to the spun fiber filter (10.1% for Giardia; 16.0% for Cryptosporidium). The Filterite filters were easier and faster to process than the polypropylene spun fiber filters. There was no significant difference in the recovery of protozoa from 1MDS and DPPPY filters. Co-collection of viruses and protozoan parasites from water onto the same filter is possible and can reduce the time and cost of routine water monitoring.

  3. Optimization of polyphenol removal from kiwifruit juice using a macroporous resin.

    PubMed

    Gao, Zhenpeng; Yu, Zhifang; Yue, Tianli; Quek, Siew Young

    2017-06-01

    The separation of polyphenols from kiwifruit juice is essential for enhancing sensory properties and prevent the browning reaction in juice during processing and storage. The present study investigated the dynamic adsorption and desorption of polyphenols in kiwifruit juice using AB-8 resin. The model obtained could be successfully applied to predict the experimental results of dynamic adsorption capacity (DAC) and dynamic desorption quantity (DDQ). The results showed that dynamic adsorption of polyphenols could be optimised in a juice concentration of 19 °Brix, with a feed flow-rate of 1.3 mL min -1 and a feed volume of 7 bed volume (BV). The optimum conditions for dynamic desorption of polyphenols from the AB-8 resin were an ethanol concentration of 43% (v/v), an elute flow-rate of 2.2 mL min -1 and an elute volume of 3 BV. The optimized DAC value was 3.16 g of polyphenols kg -1 resin, whereas that for DDQ was 917.5 g kg -1 , with both values being consistent with the predicted values generated by the regression models. The major polyphenols in the dynamic desorption solution consisted of seven compositions. The present study could be scaled-up using a continuous column system for industrial application, thus contributing to the improved flavor and color of kiwifruit juice. © 2016 Society of Chemical Industry. © 2016 Society of Chemical Industry.

  4. Co-elution phenomena in polymer mixtures studied by asymmetric flow field-flow fractionation.

    PubMed

    Zielke, Claudia; Fuentes, Catalina; Piculell, Lennart; Nilsson, Lars

    2018-01-12

    Most polymers generally have complex characteristics. Analysis and understanding of these characteristics is crucial as they, for instance, influence functionality. Separation and analysis of samples of polymers, biopolymers in particular, is challenging since they often display broad distributions in size, structure and molar mass (M) and/or a tendency to form aggregates. Only few analytical techniques are suitable for the task. AF4-MALS-dRI is highly suited for the task, but the analysis can nevertheless be especially challenging for heterogeneous mixtures of polymers that exhibit wide size distributions or aggregation. For such systems, systematic and thorough method development is clearly a requirement. This is the purpose of the present work, where we approach the problem of heterogeneous polymer samples systematically by analyzing mixtures of two different polymers which are also characterized individually. An often observed phenomenon in AF4 of samples with a high polydispersity is a downturn in M vs. elution time, especially common at high retention. This result is often dismissed as an artifact attributed to various errors in detection and data processing. In this work, we utilize AF4-MALS-dRI to separate and analyze binary mixtures of the well-known polysaccharides pullulan and glycogen, or pullulan and poly(ethylene oxide), respectively, in solution. The results show that an observed downturn - or even an upturn - in M can be a correct result, caused by inherent properties of the analyzed polymers. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Endovascular Gene Delivery from a Stent Platform: Gene- Eluting Stents

    PubMed Central

    Fishbein, Ilia; Chorny, Michael; Adamo, Richard F; Forbes, Scott P; Corrales, Ricardo A; Alferiev, Ivan S; Levy, Robert J

    2015-01-01

    A synergistic impact of research in the fields of post-angioplasty restenosis, drug-eluting stents and vascular gene therapy over the past 15 years has shaped the concept of gene-eluting stents. Gene-eluting stents hold promise of overcoming some biological and technical problems inherent to drug-eluting stent technology. As the field of gene-eluting stents matures it becomes evident that all three main design modules of a gene-eluting stent: a therapeutic transgene, a vector and a delivery system are equally important for accomplishing sustained inhibition of neointimal formation in arteries treated with gene delivery stents. This review summarizes prior work on stent-based gene delivery and discusses the main optimization strategies required to move the field of gene-eluting stents to clinical translation. PMID:26225356

  6. Two-step extraction method for lead isotope fractionation to reveal anthropogenic lead pollution.

    PubMed

    Katahira, Kenshi; Moriwaki, Hiroshi; Kamura, Kazuo; Yamazaki, Hideo

    2018-05-28

    This study developed the 2-step extraction method which eluted the Pb adsorbing on the surface of sediments in the first solution by aqua regia and extracted the Pb absorbed inside particles into the second solution by mixed acid of nitric acid, hydrofluoric acid and hydrogen peroxide solution. We applied the method to sediments in the enclosed water area and found out that the isotope ratios of Pb in the second solution represented those of natural origin. This advantage of the method makes it possible to distinguish the Pb between natural origin and anthropogenic source on the basis of the isotope ratios. The results showed that the method was useful to discuss the Pb sources and that anthropogenic Pb in the sediment samples analysed was mainly derived from China because of transboundary air pollution.

  7. A tool for selective inline quantification of co-eluting proteins in chromatography using spectral analysis and partial least squares regression.

    PubMed

    Brestrich, Nina; Briskot, Till; Osberghaus, Anna; Hubbuch, Jürgen

    2014-07-01

    Selective quantification of co-eluting proteins in chromatography is usually performed by offline analytics. This is time-consuming and can lead to late detection of irregularities in chromatography processes. To overcome this analytical bottleneck, a methodology for selective protein quantification in multicomponent mixtures by means of spectral data and partial least squares regression was presented in two previous studies. In this paper, a powerful integration of software and chromatography hardware will be introduced that enables the applicability of this methodology for a selective inline quantification of co-eluting proteins in chromatography. A specific setup consisting of a conventional liquid chromatography system, a diode array detector, and a software interface to Matlab® was developed. The established tool for selective inline quantification was successfully applied for a peak deconvolution of a co-eluting ternary protein mixture consisting of lysozyme, ribonuclease A, and cytochrome c on SP Sepharose FF. Compared to common offline analytics based on collected fractions, no loss of information regarding the retention volumes and peak flanks was observed. A comparison between the mass balances of both analytical methods showed, that the inline quantification tool can be applied for a rapid determination of pool yields. Finally, the achieved inline peak deconvolution was successfully applied to make product purity-based real-time pooling decisions. This makes the established tool for selective inline quantification a valuable approach for inline monitoring and control of chromatographic purification steps and just in time reaction on process irregularities. © 2014 Wiley Periodicals, Inc.

  8. Synthesis and Evaluation of Strychnos Alkaloids as MDR Reversal Agents for Cancer Cell Eradication

    DTIC Science & Technology

    2014-01-01

    followed by magnesium in MeOH to afford 11 in 75% yield (one-pot). Alkylation with (Z)-2-iodobutenyl bromide23 and acyla- tion with bromoacetyl chloride...eluting with MeOH/CH2Cl2 (0.4:9.6? 1:9). The material was washed with a solution of 25% aq NaOH (10 mL), which afforded 24 mg (71%) of Table 2...with MeOH/CH2Cl2 (0.4:9.6? 1:9). The material was washed with a solution of 25% aq NaOH (10 mL), which afforded 90 mg (86%) of 2 as yellow liquid

  9. Immunoaffinity centrifugal precipitation chromatography.

    PubMed

    Qi, Lin; Ito, Yoichiro

    2007-06-01

    Purification of proteins based on immunoaffinity has been performed using a solid support coated with antibody against the target proteins. The method requires immobilizing the antibody onto the solid support using protein A or G, and has a risk of adsorptive loss of target proteins onto the solid support. Centrifugal precipitation chromatography has been successfully used to purify enzymes, such as ketosteroid isomerase and hyaluronidase without the use of solid support. The purpose of this study is to demonstrate that immunoaffinity centrifugal precipitation chromatography is capable of isolating an antigen by exploiting antigen-antibody binding. The separation was initiated by filling both channels with 40% saturated ammonium sulfate (AS) of pH 4-4.5 followed by loading 20 microl of human plasma (National Institutes of Health blood bank) mixed with 2 mg of rabbit anti-HSA (human serum protein) antibody (Sigma). Then, the sample channel was eluted with water at 0.03 ml/min and AS channel with 40% AS solution of pH 4-4.5 at 1 ml/min until all non-binding components were eluted. Then, the releasing reagent (50% AS solution containing 0.5 M glycine and 10% ammonium hydroxide at pH 10) was introduced through the AS channel to release the target protein (HSA). The retained antibody was recovered by eluting the sample channel with water at 1 ml/min. A hollow fiber membrane device at the outlet (MicroKros, Spectrum, New Brunswick, NJ, USA) was provided on-line dialysis of the eluent before fractions were collected, so that the fractions could be analyzed by SDS-PAGE (sodium dodecyl sulfate - polyacrylamide gel electrophoresis) without further dialysis. The current method does not require immobilizing the antibody onto a matrix, which is used by the conventional immunoaffinity chromatography. This method ensures full recovery of the antigen and antibody, and it may be applied to purification of other proteins.

  10. Automated centrifugal-microfluidic platform for DNA purification using laser burst valve and coriolis effect.

    PubMed

    Choi, Min-Seong; Yoo, Jae-Chern

    2015-04-01

    We report a fully automated DNA purification platform with a micropored membrane in the channel utilizing centrifugal microfluidics on a lab-on-a-disc (LOD). The microfluidic flow in the LOD, into which the reagents are injected for DNA purification, is controlled by a single motor and laser burst valve. The sample and reagents pass successively through the micropored membrane in the channel when each laser burst valve is opened. The Coriolis effect is used by rotating the LOD bi-directionally to increase the purity of the DNA, thereby preventing the mixing of the waste and elution solutions. The total process from the lysed sample injection into the LOD to obtaining the purified DNA was finished within 7 min with only one manual step. The experimental result for Salmonella shows that the proposed microfluidic platform is comparable to the existing devices in terms of the purity and yield of DNA.

  11. Immobilized aptamer paper spray ionization source for ion mobility spectrometry.

    PubMed

    Zargar, Tahereh; Khayamian, Taghi; Jafari, Mohammad T

    2017-01-05

    A selective thin-film microextraction based on aptamer immobilized on cellulose paper was used as a paper spray ionization source for ion mobility spectrometry (PSI-IMS), for the first time. In this method, the paper is not only used as an ionization source but also it is utilized for the selective extraction of analyte, based on immobilized aptamer. This combination integrates both sample preparation and analyte ionization in a Whatman paper. To that end, an appropriate sample introduction system with a novel design was constructed for the paper spray ionization source. Using this system, a continuous solvent flow works as an elution and spray solvent simultaneously. In this method, analyte is adsorbed on a triangular paper with immobilized aptamer and then it is desorbed and ionized by elution solvent and applied high voltage on paper, respectively. The effects of different experimental parameters such as applied voltage, angle of paper tip, distance between paper tip and counter electrode, elution solvent type, and solvent flow rate were optimized. The proposed method was exhaustively validated in terms of sensitivity and reproducibility by analyzing the standard solutions of codeine and acetamiprid. The analytical results obtained are promising enough to ensure the use of immobilized aptamer paper-spray as both the extraction and ionization techniques in IMS for direct analysis of biomedicine. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. Integrated electrokinetically driven microfluidic devices with pH-mediated solid-phase extraction coupled to microchip electrophoresis for preterm birth biomarkers.

    PubMed

    Sonker, Mukul; Knob, Radim; Sahore, Vishal; Woolley, Adam T

    2017-07-01

    Integration in microfluidics is important for achieving automation. Sample preconcentration integrated with separation in a microfluidic setup can have a substantial impact on rapid analysis of low-abundance disease biomarkers. Here, we have developed a microfluidic device that uses pH-mediated solid-phase extraction (SPE) for the enrichment and elution of preterm birth (PTB) biomarkers. Furthermore, this SPE module was integrated with microchip electrophoresis for combined enrichment and separation of multiple analytes, including a PTB peptide biomarker (P1). A reversed-phase octyl methacrylate monolith was polymerized as the SPE medium in polyethylene glycol diacrylate modified cyclic olefin copolymer microfluidic channels. Eluent for pH-mediated SPE of PTB biomarkers on the monolith was optimized using different pH values and ionic concentrations. Nearly 50-fold enrichment was observed in single channel SPE devices for a low nanomolar solution of P1, with great elution time reproducibility (<7% RSD). The monolith binding capacity was determined to be 400 pg (0.2 pmol). A mixture of a model peptide (FA) and a PTB biomarker (P1) was extracted, eluted, injected, and then separated by microchip electrophoresis in our integrated device with ∼15-fold enrichment. This device shows important progress towards an integrated electrokinetically operated platform for preconcentration and separation of biomarkers. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Process development for robust removal of aggregates using cation exchange chromatography in monoclonal antibody purification with implementation of quality by design.

    PubMed

    Xu, Zhihao; Li, Jason; Zhou, Joe X

    2012-01-01

    Aggregate removal is one of the most important aspects in monoclonal antibody (mAb) purification. Cation-exchange chromatography (CEX), a widely used polishing step in mAb purification, is able to clear both process-related impurities and product-related impurities. In this study, with the implementation of quality by design (QbD), a process development approach for robust removal of aggregates using CEX is described. First, resin screening studies were performed and a suitable CEX resin was chosen because of its relatively better selectivity and higher dynamic binding capacity. Second, a pH-conductivity hybrid gradient elution method for the CEX was established, and the risk assessment for the process was carried out. Third, a process characterization study was used to evaluate the impact of the potentially important process parameters on the process performance with respect to aggregate removal. Accordingly, a process design space was established. Aggregate level in load is the critical parameter. Its operating range is set at 0-3% and the acceptable range is set at 0-5%. Equilibration buffer is the key parameter. Its operating range is set at 40 ± 5 mM acetate, pH 5.0 ± 0.1, and acceptable range is set at 40 ± 10 mM acetate, pH 5.0 ± 0.2. Elution buffer, load mass, and gradient elution volume are non-key parameters; their operating ranges and acceptable ranges are equally set at 250 ± 10 mM acetate, pH 6.0 ± 0.2, 45 ± 10 g/L resin, and 10 ± 20% CV respectively. Finally, the process was scaled up 80 times and the impurities removal profiles were revealed. Three scaled-up runs showed that the size-exclusion chromatography (SEC) purity of the CEX pool was 99.8% or above and the step yield was above 92%, thereby proving that the process is both consistent and robust.

  14. Diagnosis of Enterocytozoon bieneusi by PCR in Stool Samples Eluted from Filter Paper Disks

    PubMed Central

    Carnevale, Silvana; Velásquez, Jorge N.; Labbé, Jorge H.; Chertcoff, Agustín; Cabrera, Marta G.; Rodríguez, Mónica I.

    2000-01-01

    We report a PCR-based assay for the detection of Enterocytozoon bieneusi. We extracted DNA from feces which had been applied to filter paper disks and evaluated four preserving solutions. Infected specimens were identified by electrophoresis of amplicons from concentrated formalin-fixed samples and unconcentrated fresh feces. Our findings demonstrate that this methodology is effective for sample collection, mailing, and diagnosis of this pathogen. PMID:10799469

  15. Tissue Adhesives for Battlefield Hemorrhage Control

    DTIC Science & Technology

    1996-04-01

    extremely high bioburden it is felt that a rapid elution of the CHX or antimicrobial could be advantages. It is this rapid dumping of the 8000 Mw film...absorbance of each test article solution was determined spectrophotometrically at 545 nm. Similarly, absorbances were recorded for the positive...used to calculate percent hemolysis for the test article . Results showed 0.0% hemolysis for both test #1 and test #2, with a mean hemolysis of 0.0

  16. SEPARATING HAFNIUM FROM ZIRCONIUM

    DOEpatents

    Lister, B.A.J.; Duncan, J.F.

    1956-08-21

    A dilute aqueous solution of zirconyl chloride which is 1N to 2N in HCl is passed through a column of a cation exchange resin in acid form thereby absorbing both zirconium and associated hafnium impurity in the mesin. The cation exchange material with the absorbate is then eluted with aqueous sulfuric acid of a O.8N to 1.2N strength. The first portion of the eluate contains the zirconium substantially free of hafnium.

  17. Effect of cationic monomer content on polyacrylamide copolymers by frit-inlet asymmetrical flow field-flow fractionation/multi-angle light scattering.

    PubMed

    Lee, Hyejin; Kim, Jin Yong; Choi, Woonjin; Moon, Myeong Hee

    2017-06-23

    In this study, ultrahigh-molecular-weight (MW) (>10 7 Da) cationic polyacrylamides (C-PAMs), which are water-soluble polymers used in waste water treatment, were characterized using frit-inlet asymmetrical flow field-flow fractionation coupled with multi-angle light scattering and differential refractive detection. C-PAMs copolymerized with acryloxyethyltrimethyl ammonium chloride (DAC) were prepared by varying the feed amount of cationic monomer, polymerization method (solution vs. emulsion), and degree of branching. The MW of the copolymers prepared using emulsion polymerization (10 7 -10 9 Da) was generally larger than that of copolymers prepared using solution polymerization (4×10 7 -10 8 Da). When the amount of cationic monomer was increased from 10 to 55mol% in solution polymerization, hydrophobic contraction of the core induced formation of more compact C-PAMs. The copolymers prepared using emulsion polymerization formed highly aggregated or supercoil structures owing to increased intermolecular hydrophobic interaction when less cationic monomer was used. However, the MW decreased with increased cationic group content. In addition, C-PAMs larger than ∼10 8 Da prepared using the emulsion method were separated by steric/hyperlayer elution mode while those in the 10 7 -10 8 Da range were analyzed in either normal or steric/hyperlayer mode depending on the decay patterns of field programming. Moreover, branched copolymers were found to be resolved with different elution modes under the same field decay pattern depending on the degree of branching: steric/hyperlayer for low-branching and normal for high-branching C-PAMs. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Using the liquid nature of the stationary phase in countercurrent chromatography. IV. The cocurrent CCC method.

    PubMed

    Berthod, Alain; Hassoun, Mahmoud

    2006-05-26

    The retention volumes of solutes in countercurrent chromatography (CCC) are directly proportional to their distribution coefficients, K(D) in the biphasic liquid system used as mobile and stationary phase in the CCC column. The cocurrent CCC method consists in putting the liquid "stationary" phase in slow motion in the same direction as the mobile phase. A mixture of five steroid compounds of widely differing polarities was used as a test mixture to evaluate the capabilities of the method with the biphasic liquid system made of water/methanol/ethyl acetate/heptane 6/5/6/5 (v/v) and a 53 mL CCC column of the coil planet centrifuge type. It is shown that the chromatographic resolution obtained in cocurrent CCC is very good because the solute band broadening is minimized as long as the solute is located inside the "stationary" phase. Pushing the method at its limits, it is demonstrated that the five steroids can still be (partly) separated when the flow rate of the two liquid phases is the same (2 mL/min). This is due to the higher volume of upper phase (72% of the column volume) contained inside the CCC column producing a lower linear speed compared to the aqueous lower phase linear speed. The capabilities of the cocurrent CCC method compare well with those of the gradient elution method in HPLC. Continuous detection is a problem due to the fact that two immiscible liquid phases elute from the column. It was partly solved using an evaporative light scattering detector.

  19. Ultrathin, bioresorbable polymer sirolimus-eluting stents versus thin, durable polymer everolimus-eluting stents in patients undergoing coronary revascularisation (BIOFLOW V): a randomised trial.

    PubMed

    Kandzari, David E; Mauri, Laura; Koolen, Jacques J; Massaro, Joseph M; Doros, Gheorghe; Garcia-Garcia, Hector M; Bennett, Johan; Roguin, Ariel; Gharib, Elie G; Cutlip, Donald E; Waksman, Ron

    2017-10-21

    The development of coronary drug-eluting stents has included use of new metal alloys, changes in stent architecture, and use of bioresorbable polymers. Whether these advancements improve clinical safety and efficacy has not been shown in previous randomised trials. We aimed to examine the clinical outcomes of a bioresorbable polymer sirolimus-eluting stent compared with a durable polymer everolimus-eluting stent in a broad patient population undergoing percutaneous coronary intervention. BIOFLOW V was an international, randomised trial done in patients undergoing elective and urgent percutaneous coronary intervention in 90 hospitals in 13 countries (Australia, Belgium, Canada, Denmark, Germany, Hungary, Israel, the Netherlands, New Zealand, South Korea, Spain, Switzerland, and the USA). Eligible patients were those aged 18 years or older with ischaemic heart disease undergoing planned stent implantation in de-novo, native coronary lesions. Patients were randomly assigned (2:1) to either an ultrathin strut (60 μm) bioresorbable polymer sirolimus-eluting stent or to a durable polymer everolimus-eluting stent. Randomisation was via a central web-based data capture system (mixed blocks of 3 and 6), and stratified by study site. The primary endpoint was 12-month target lesion failure. The primary non-inferiority comparison combined these data from two additional randomised trials of bioresorbable polymer sirolimus-eluting stent and durable polymer everolimus-eluting stent with Bayesian methods. Analysis was by intention to treat. The trial is registered with ClinicalTrials.gov, number NCT02389946. Between May 8, 2015, and March 31, 2016, 4772 patients were recruited into the study. 1334 patients met inclusion criteria and were randomly assigned to treatment with bioresorbable polymer sirolimus-eluting stents (n=884) or durable polymer everolimus-eluting stents (n=450). 52 (6%) of 883 patients in the bioresorbable polymer sirolimus-eluting stent group and 41 (10%) of 427 patients in the durable polymer everolimus-eluting stent group met the 12-month primary endpoint of target lesion failure (95% CI -6·84 to -0·29, p=0·0399), with differences in target vessel myocardial infarction (39 [5%] of 831 patients vs 35 [8%] of 424 patients, p=0·0155). The posterior probability that the bioresorbable polymer sirolimus-eluting stent is non-inferior to the durable polymer everolimus-eluting stent was 100% (Bayesian analysis, difference in target lesion failure frequency -2·6% [95% credible interval -5·5 to 0·1], non-inferiority margin 3·85%, n=2208). The outperformance of the ultrathin, bioresorbable polymer sirolimus-eluting stent over the durable polymer everolimus-eluting stent in a complex patient population undergoing percutaneous coronary intervention suggests a new direction in improving next generation drug-eluting stent technology. BIOTRONIK. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. The Purification and Concentration of Hog Cholera Virus*

    PubMed Central

    Cunliffe, H. R.; Rebers, P. A.

    1968-01-01

    Partial purification of hog cholera virus (HCV) using a simple batch-type chromatographic procedure with magnetic ferric oxide (MFO) is described. Infectious HCV was adsorbed from isotonic solutions to MFO and was eluted under conditions of low ionic strength and high pH. Aqueous solutions of 0.01 M sodium cyanide or 0.0003 M ammonium hydroxide effectively dissociated MFO-HCV complexes. The data indicate that 50 to 100% of the original HCV infectivity was recovered concomitant with a 90 to 95% reduction of extraneous organic nitrogen. MFO-purified HCV was concentrated by density gradient type centrifugations in buffered solutions of cesium chloride and sucrose. Prolonged isodensity centrifugations of concentrated MFO-purified HCV indicated a buoyant density of 1.14 to 1.15 gm/ml for the strain of virus used. PMID:15846899

  1. Titanium-nitride-oxide-coated coronary stents: insights from the available evidence.

    PubMed

    Karjalainen, Pasi P; Nammas, Wail

    2017-06-01

    Coating of stent surface with a biocompatible material is suggested to improve stent safety profile. A proprietary process was developed to coat titanium-nitride-oxide on the stent surface, based on plasma technology that uses the nano-synthesis of gas and metal. Preclinical in vitro and in vivo investigation confirmed blood compatibility of titanium (nitride-) oxide films. Titanium-nitride-oxide-coated stents demonstrated a better angiographic outcome, compared with bare-metal stents at mid-term follow-up; however, they failed to achieve non-inferiority for angiographic outcome versus second-generation drug-eluting stents. Observational studies showed adequate clinical outcome at mid-term follow-up. Non-randomized studies showed an outcome of titanium-nitride-oxide-coated stents comparable to - or better than - first-generation drug-eluting stents at long-term follow-up. Two randomized controlled trials demonstrated comparable efficacy outcome, and a better safety outcome of titanium-nitride-oxide-coated stents versus drug-eluting stents at long-term follow-up. Evaluation by optical coherence tomography at mid-term follow-up revealed better neointimal strut coverage associated with titanium-nitride-oxide-coated stents versus drug-eluting stents; yet, neointimal hyperplasia thickness was greater. Key messages Stents coated with titanium-nitride-oxide demonstrated biocompatibility in preclinical studies: they inhibit platelet and fibrin deposition, and reduce neointimal growth. In observational and non-randomized studies, titanium-nitride-oxide-coated stents were associated with adequate safety and efficacy outcome. In randomized trials of patients with acute coronary syndrome, titanium-nitride-oxide-coated stents were associated with a better safety outcome, compared with drug-eluting stents; efficacy outcome was comparable.

  2. High-resolution, preparative purification of PEGylated protein using a laterally-fed membrane chromatography device.

    PubMed

    Madadkar, Pedram; Nino, Sergio Luna; Ghosh, Raja

    2016-11-01

    We discuss the use of a laterally-fed membrane chromatography (or LFMC) device for single-step purification of mono-PEGylated lysozyme. Recent studies have shown such LFMC devices to be suitable for high-resolution, multi-component separation of proteins in the bind-and-elute mode. The device used in this study contained a stack of rectangular cation-exchange membranes having 9.25mL bed volume. PEGylation of lysozyme was carried out in batch mode using 5kDa methoxy-polyethyleneglycol propionaldehyde (or m-PEG propionaldehyde) in the presence of sodium cyanoborohydride as reducing agent. Membrane chromatographic separation was carried out at 1.62 membrane bed volumes per minute flow rate, in the bind-and-elute mode. When a salt gradient was applied, the higher PEGylated forms of lysozyme (i.e. the byproducts) eluted earlier than mono-PEGylated lysozyme (the target product), while lysozyme eluted last. Under elution conditions optimized for resolution and speed, the separation could be carried out in less than 15 membrane bed volumes. High purity and recovery of mono-PEGylated lysozyme was obtained. The resolution of separation of mono-PEGylated lysozyme obtained under the above condition was comparable to that reported in the literature for equivalent cation-exchange resin columns while the flow rate expressed in bed volumes/min was 21.7 times higher. Also, the number of theoretical plates per meter was significantly higher with the LFMC device. Therefore the LFMC based purification process discussed in this paper combined high-productivity with high-resolution. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Precision-controlled elution of a 82Sr/82Rb generator for cardiac perfusion imaging with positron emission tomography

    NASA Astrophysics Data System (ADS)

    Klein, R.; Adler, A.; Beanlands, R. S.; de Kemp, R. A.

    2007-02-01

    A rubidium-82 (82Rb) elution system is described for use with positron emission tomography. Due to the short half-life of 82Rb (76 s), the system physics must be modelled precisely to account for transport delay and the associated activity decay and dispersion. Saline flow is switched between a 82Sr/82Rb generator and a bypass line to achieve a constant-activity elution of 82Rb. Pulse width modulation (PWM) of a solenoid valve is compared to simple threshold control as a means to simulate a proportional valve. A predictive-corrective control (PCC) algorithm is developed which produces a constant-activity elution within the constraints of long feedback delay and short elution time. The system model parameters are adjusted through a self-tuning algorithm to minimize error versus the requested time-activity profile. The system is self-calibrating with 2.5% repeatability, independent of generator activity and elution flow rate. Accurate 30 s constant-activity elutions of 10-70% of the total generator activity are achieved using both control methods. The combined PWM-PCC method provides significant improvement in precision and accuracy of the requested elution profiles. The 82Rb elution system produces accurate and reproducible constant-activity elution profiles of 82Rb activity, independent of parent 82Sr activity in the generator. More reproducible elution profiles may improve the quality of clinical and research PET perfusion studies using 82Rb.

  4. Precision-controlled elution of a 82Sr/82Rb generator for cardiac perfusion imaging with positron emission tomography.

    PubMed

    Klein, R; Adler, A; Beanlands, R S; Dekemp, R A

    2007-02-07

    A rubidium-82 ((82)Rb) elution system is described for use with positron emission tomography. Due to the short half-life of (82)Rb (76 s), the system physics must be modelled precisely to account for transport delay and the associated activity decay and dispersion. Saline flow is switched between a (82)Sr/(82)Rb generator and a bypass line to achieve a constant-activity elution of (82)Rb. Pulse width modulation (PWM) of a solenoid valve is compared to simple threshold control as a means to simulate a proportional valve. A predictive-corrective control (PCC) algorithm is developed which produces a constant-activity elution within the constraints of long feedback delay and short elution time. The system model parameters are adjusted through a self-tuning algorithm to minimize error versus the requested time-activity profile. The system is self-calibrating with 2.5% repeatability, independent of generator activity and elution flow rate. Accurate 30 s constant-activity elutions of 10-70% of the total generator activity are achieved using both control methods. The combined PWM-PCC method provides significant improvement in precision and accuracy of the requested elution profiles. The (82)Rb elution system produces accurate and reproducible constant-activity elution profiles of (82)Rb activity, independent of parent (82)Sr activity in the generator. More reproducible elution profiles may improve the quality of clinical and research PET perfusion studies using (82)Rb.

  5. In vitro hemocompatibility and cytocompatibility of dexamethasone-eluting PLGA stent coatings

    NASA Astrophysics Data System (ADS)

    Zhang, Jiang; Liu, Yang; Luo, Rifang; Chen, Si; Li, Xin; Yuan, Shuheng; Wang, Jin; Huang, Nan

    2015-02-01

    Drug-eluting stents (DESs) have been an important breakthrough for interventional cardiology applications since 2002. Though successful in reducing restenosis, some adverse clinical problems still emerged, which were mostly caused by the bare-metal stents and non-biodegradable polymer coatings, associated with the delayed endothelialization process. In this study, dexamethasone-loaded poly (lactic-co-glycolic acid) (PLGA) coatings were developed to explore the potential application of dexamethasone-eluting stents. Dexamethasone-eluting PLGA stents were prepared using ultrasonic atomization spray method. For other tests like stability and cytocompatibility and hemocompatibility tests, dexamethasone loaded coatings were deposited on 316L SS wafers. Fourier transform-infrared spectroscopy (FT-IR) results demonstrated that there was no chemical reaction between PLGA and dexamethasone. The balloon expansion experiment and surface morphology observation suggested that the stent coatings were smooth and uniform, and could also withstand the compressive and tensile strains imparted without cracking after stent expansion. The drug release behavior in vitro indicated that dexamethasone existed burst release within 1 day, but it presented linear release characteristics after 6 days. In vitro platelets adhesion, activation test and APTT test were also done, which showed that after blending dexamethasone into PLGA, the hemocompatibility was improved. Besides, dexamethasone and dexamethasone-loaded PLGA coatings could significantly inhibit the attachment and proliferation of smooth muscle cells.

  6. Absolute configuration of 2,2',3,3',6-pentachlorinatedbiphenyl (PCB 84) atropisomers.

    PubMed

    Li, Xueshu; Parkin, Sean R; Lehmler, Hans-Joachim

    2017-05-23

    Nineteen polychlorinated biphenyl (PCB) congeners, such as 2,2',3,3',6-pentachlorobiphenyl (PCB 84), display axial chirality because they form stable rotational isomers, or atropisomers, that are non-superimposable mirror images of each other. Although chiral PCBs undergo atropselective biotransformation and atropselectively alter biological processes, the absolute structure of only a few PCB atropisomers has been determined experimentally. To help close this knowledge gap, pure PCB 84 atropisomers were obtained by semi-preparative liquid chromatography with two serially connected Nucleodex β-PM columns. The absolute configuration of both atropisomers was determined by X-ray single-crystal diffraction. The PCB 84 atropisomer eluting first and second on the Nucleodex β-PM column correspond to (aR)-(-)-PCB 84 and (aS)-(+)-PCB 84, respectively. Enantioselective gas chromatographic analysis with the β-cyclodextrin-based CP-Chirasil-Dex CB gas chromatography column showed the same elution order as the Nucleodex β-PM column. Based on earlier reports, the atropisomers eluting first and second on the BGB-172 gas chromatography column are (aR)-(-)-PCB 84 and (aS)-(+)-PCB 84, respectively. An inversion of the elution order is observed on the Cyclosil-B gas chromatography and Cellulose-3 liquid chromatography columns. These results advance the interpretation of environmental and human biomonitoring as well as toxicological studies.

  7. Discontinuous pH gradient-mediated separation of TiO2-enriched phosphopeptides

    PubMed Central

    Park, Sung-Soo; Maudsley, Stuart

    2010-01-01

    Global profiling of phosphoproteomes has proven a great challenge due to the relatively low stoichiometry of protein phosphorylation and poor ionization efficiency in mass spectrometers. Effective, physiologically-relevant, phosphoproteome research relies on the efficient phosphopeptide enrichment from complex samples. Immobilized metal affinity chromatography and titanium dioxide chromatography (TOC) can greatly assist selective phosphopeptide enrichment. However, the complexity of resultant enriched samples is often still high, suggesting that further separation of enriched phosphopeptides is required. We have developed a pH-gradient elution technique for enhanced phosphopeptide identification in conjunction with TOC. Using this process, we have demonstrated its superiority to the traditional ‘one-pot’ strategies for differential protein identification. Our technique generated a highly specific separation of phosphopeptides by an applied pH-gradient between 9.2 and 11.3. The most efficient elution range for high-resolution phosphopeptide separation was between pH 9.2 and 9.4. High-resolution separation of multiply-phosphorylated peptides was primarily achieved using elution ranges > pH 9.4. Investigation of phosphopeptide sequences identified in each pH fraction indicated that phosphopeptides with phosphorylated residues proximal to acidic residues, including glutamic acid, aspartic acid, and other phosphorylated residues, were preferentially eluted at higher pH values. PMID:20946866

  8. Lesson from the stoichiometry determination of the cohesin complex: a short protease mediated elution increases the recovery from cross-linked antibody-conjugated beads.

    PubMed

    Holzmann, Johann; Fuchs, Johannes; Pichler, Peter; Peters, Jan-Michael; Mechtler, Karl

    2011-02-04

    Affinity purification of proteins using antibodies coupled to beads and subsequent mass spectrometric analysis has become a standard technique for the identification of protein complexes. With the recent transfer of the isotope dilution mass spectrometry principle (IDMS) to the field of proteomics, quantitative analyses-such as the stoichiometry determination of protein complexes-have become achievable. Traditionally proteins were eluted from antibody-conjugated beads using glycine at low pH or using diluted acids such as HCl, TFA, or FA, but elution was often found to be incomplete. Using the cohesin complex and the anaphase promoting complex/cyclosome (APC/C) as examples, we show that a short 15-60 min predigestion with a protease such as LysC (modified on-bead digest termed protease elution) increases the elution efficiency 2- to 3-fold compared to standard acid elution protocols. While longer incubation periods-as performed in standard on-bead digestion-led to partial proteolysis of the cross-linked antibodies, no or only insignificant cleavage was observed after 15-60 min protease mediated elution. Using the protease elution method, we successfully determined the stoichiometry of the cohesin complex by absolute quantification of the four core subunits using LC-SRM analysis and 19 reference peptides generated with the EtEP strategy. Protease elution was 3-fold more efficient compared to HCl elution, but measurements using both elution techniques are in agreement with a 1:1:1:1 stoichiometry. Furthermore, using isoform specific reference peptides, we determined the exact STAG1:STAG2 stoichiometry within the population of cohesin complexes. In summary, we show that the protease elution protocol increases the recovery from affinity beads and is compatible with quantitative measurements such as the stoichiometry determination of protein complexes.

  9. Effect of blood flow on near-the-wall mass transport of drugs and other bioactive agents: a simple formula to estimate boundary layer concentrations.

    PubMed

    Rugonyi, Sandra

    2008-04-01

    Transport of bioactive agents through the blood is essential for cardiovascular regulatory processes and drug delivery. Bioactive agents and other solutes infused into the blood through the wall of a blood vessel or released into the blood from an area in the vessel wall spread downstream of the infusion/release region and form a thin boundary layer in which solute concentration is higher than in the rest of the blood. Bioactive agents distributed along the vessel wall affect endothelial cells and regulate biological processes, such as thrombus formation, atherogenesis, and vascular remodeling. To calculate the concentration of solutes in the boundary layer, researchers have generally used numerical simulations. However, to investigate the effect of blood flow, infusion rate, and vessel geometry on the concentration of different solutes, many simulations are needed, leading to a time-consuming effort. In this paper, a relatively simple formula to quantify concentrations in a tube downstream of an infusion/release region is presented. Given known blood-flow rates, tube radius, solute diffusivity, and the length of the infusion region, this formula can be used to quickly estimate solute concentrations when infusion rates are known or to estimate infusion rates when solute concentrations at a point downstream of the infusion region are known. The developed formula is based on boundary layer theory and physical principles. The formula is an approximate solution of the advection-diffusion equations in the boundary layer region when solute concentration is small (dilute solution), infusion rate is modeled as a mass flux, and there is no transport of solute through the wall or chemical reactions downstream of the infusion region. Wall concentrations calculated using the formula developed in this paper were compared to the results from finite element models. Agreement between the results was within 10%. The developed formula could be used in experimental procedures to evaluate drug efficacy, in the design of drug-eluting stents, and to calculate rates of release of bioactive substances at active surfaces using downstream concentration measurements. In addition to being simple and fast to use, the formula gives accurate quantifications of concentrations and infusion rates under steady-state and oscillatory flow conditions, and therefore can be used to estimate boundary layer concentrations under physiological conditions.

  10. Drug-eluting versus bare-metal coronary stents: where are we now?

    PubMed

    Amoroso, Nicholas S; Bangalore, Sripal

    2012-11-01

    Drug-eluting stents have dramatically reduced the risk of restenosis, but concerns of an increased risk of stent thrombosis have provided uncertainty about their use. Recent studies have continued to show improved procedural and clinical outcomes with drug-eluting stents both in the setting of acute coronary syndromes and stable coronary artery disease. Newer generation drug-eluting stents (especially everolimus-eluting stents) have been shown to be not only efficacious but also safe with reduced risk of stent thrombosis when compared with bare-metal stents, potentially changing the benchmark for stent safety from bare-metal stents to everolimus-eluting stents. While much progress is being made in the development of bioabsorbable polymer stents, nonpolymer stents and bioabsorbable stent technology, it remains to be seen whether these stents will have superior safety and efficacy outcomes compared with the already much improved rates of revascularization and stent thrombosis seen with newer generation stents (everolimus-eluting stents and resolute zotarolimus-eluting stents).

  11. Biodegradable-polymer drug-eluting stents vs. bare metal stents vs. durable-polymer drug-eluting stents: a systematic review and Bayesian approach network meta-analysis.

    PubMed

    Kang, Si-Hyuck; Park, Kyung Woo; Kang, Do-Yoon; Lim, Woo-Hyun; Park, Kyung Taek; Han, Jung-Kyu; Kang, Hyun-Jae; Koo, Bon-Kwon; Oh, Byung-Hee; Park, Young-Bae; Kandzari, David E; Cohen, David J; Hwang, Seung-Sik; Kim, Hyo-Soo

    2014-05-01

    The aim of this study was to compare the safety and efficacy of biodegradable-polymer (BP) drug-eluting stents (DES), bare metal stents (BMS), and durable-polymer DES in patients undergoing coronary revascularization, we performed a systematic review and network meta-analysis using a Bayesian framework. Study stents included BMS, paclitaxel-eluting (PES), sirolimus-eluting (SES), endeavor zotarolimus-eluting (ZES-E), cobalt-chromium everolimus-eluting (CoCr-EES), platinium-chromium everolimus-eluting (PtCr-EES), resolute zotarolimus-eluting (ZES-R), and BP biolimus-eluting stents (BP-BES). After a systematic electronic search, 113 trials with 90 584 patients were selected. The principal endpoint was definite or probable stent thrombosis (ST) defined according to the Academic Research Consortium within 1 year. Biodegradable polymer-biolimus-eluting stents [OR, 0.56; 95% credible interval (CrI), 0.33-0.90], SES (OR, 0.53; 95% CrI, 0.38-0.73), CoCr-EES (OR, 0.34; 95% CrI, 0.23-0.52), and PtCr-EES (OR, 0.31; 95% CrI, 0.10-0.90) were all superior to BMS in terms of definite or probable ST within 1 year. Cobalt-chromium everolimus-eluting stents demonstrated the lowest risk of ST of all stents at all times after stent implantation. Biodegradable polymer-biolimus-eluting stents was associated with a higher risk of definite or probable ST than CoCr-EES (OR, 1.72; 95% CrI, 1.04-2.98). All DES reduced the need for repeat revascularization, and all but PES reduced the risk of myocardial infarction compared with BMS. All DESs but PES and ZES-E were superior to BMS in terms of ST within 1 year. Cobalt-chromium everolimus-eluting stents was safer than any DES even including BP-BES. Our results suggest that not only the biodegradability of polymer, but the optimal combination of stent alloy, design, strut thickness, polymer, and drug all combined determine the safety of DES.

  12. [Kinetics of decamethoxine, an antimicrobial agent].

    PubMed

    Paliĭ, G K; Nazarchuk, A A; Kulakov, A I; Nazarchuk, G G; Paliĭ, D V; Bereza, B N; Oleĭnik, D P

    2014-01-01

    The kinetics of decamethoxine liberation from medical antimicrobial textiles was studied. The elution of decamethoxine was shown to be a complicated diffusive-kinetic process dependent on the exposure and concentration of decamethoxine.

  13. Metal elution from Ni- and Fe-based alloy reactors under hydrothermal conditions.

    PubMed

    Faisal, Muhammad; Quitain, Armando T; Urano, Shin-Ya; Daimon, Hiroyuki; Fujie, Koichi

    2004-05-20

    Elution of metals from Ni- and Fe-based alloy (i.e. Inconel 625 and SUS 316) under hydrothermal conditions was investigated. Results showed that metals could be eluted even in a short contact time. At subcritical conditions, a significant amount of Cr was extracted from SUS 316, while only traces of Ni, Fe, Mo, and Mn were eluted. In contrast, Ni was removed in significant amounts compared to Cr when Inconel 625 was tested. Several factors including temperature and contact time were found to affect elution behavior. The presence of air in the fluid even promoted elution under subcritical conditions.

  14. A novel procedure for Rubidium separation and its isotope measurements on geological samples by MC-ICP-MS

    NASA Astrophysics Data System (ADS)

    Ma, J.; Zhang, Z.; Wei, G.; Zhang, L.

    2017-12-01

    A method including a novel column Rb separation procedure and high-precision Rb isotope measurement in geological materials by using multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) in standard-sample-bracketing (SSB) mode has been developed. Sr-Spec resin was employed, in which the distribution coefficients for Rb, K, Ba and Sr are different in nitric acid, to sequentially separate them from the matrix. The dissolved samples were loaded on the column in 3 M HNO3, the main matrix such as Al, Ca, Fe, Mg, Mn and Na were removed by rinsing with 4.5 mL HNO3, Rb and K were then sequentially eluted by 3 M HNO3 in different volumes. After that, Ba was eluted by 8 M HNO3, and Sr was finally eluted by Milli-Q water. This enable us to collect the pure Rb, K, Ba and Sr one by one with recovery close to 100% for their isotopic compositions measurement on MC-ICP-MS. We here focus on Rb isotope measurement. The measurement using MC-ICP-MS yielded an internal precision for δ87Rb of < ± 0.03‰ (2SE), and the external precision was generally better than ± 0.06‰ (2SD) based on the long-term results of the Rb standard solutions NIST SRM 984. A series of geological rock standards, were analyzed using this method, and the results indicate significant Rb isotope differences in different geologic materials. This will provide a powerful tool to investigate Rb isotope fractionation during geological processes.Based on this method, Rb isotope compositions from a basaltic weathering profile were carried out. The data show the lighter Rb (85Rb) isotope is preferentially leached from the weathering profile and remains heavy Rb isotope (87Rb) in the weathered residues during the incipient weathering stage. From the moderate to advanced weathering stage, the significant variations of Rb isotope were observed and multiple factors, such as leaching, adsorption, desorption, and precipitation, should play important role in fractionating Rb isotope.

  15. Drug-eluting stents. Insights from invasive imaging technologies.

    PubMed

    Honda, Yasuhiro

    2009-08-01

    Drug-eluting stents (DES) represent a revolutionary technology in their unique ability to provide both mechanical and biological solutions simultaneously to the target lesion. As a result of biological effects from the pharmacological agents and interaction of DES components with the arterial wall, considerable differences exist between DES and conventional bare metal stents (BMS), yet some of the old lessons learned in the BMS era remain clinically significant. In this context, contrast angiography provides very little information about in vivo device properties and their biomechanical effects on the arterial wall. In contrast, current catheter-based imaging tools, such as intravascular ultrasound, optical coherence tomography, and intracoronary angioscopy can offer unique insights into DES through direct assessment of the device and treated vessel in the clinical setting. This article reviews these insights from current DES with particular focus on performance and safety characteristics as well as discussing an optimal deployment technique, based upon findings obtained through the use of the invasive imaging technologies.

  16. [Determination method of polysorbates in powdered soup by HPLC].

    PubMed

    Takeda, Y; Abe, Y; Ishiwata, H; Yamada, T

    2001-04-01

    A method for qualitative and quantitative analyses of polysorbates in powdered soup by HPLC was studied. Polysorbates in samples were extracted with acetonitrile after rinsing with n-hexane to remove fats and oils. The extract was cleaned up using a Bond Elut silica gel cartridge (500 mg). The cartridge was washed with ethyl acetate and polysorbates were eluted with a small amount of acetonitrile-methanol (1:2) mixture. The eluate was treated with cobalt thiocyanate solution to form a blue complex with polysorbate. In order to determine polysorbate, the complex was subjected to HPLC with a GPC column, using a mixture of acetonitrile-water (95:5) as a mobile phase, with a detection wavelength of 620 nm. The recoveries of polysorbate 80 added to powdered soups were more than 75% and the determination limit was 0.04 mg/g. When the proposed method was applied to the determination of polysorbates in 16 commercial samples of powdered soup for instant noodles and seasoning consomme, no polysorbates were detected in any sample.

  17. Application of quality by design concept to develop a dual gradient elution stability-indicating method for cloxacillin forced degradation studies using combined mixture-process variable models.

    PubMed

    Zhang, Xia; Hu, Changqin

    2017-09-08

    Penicillins are typical of complex ionic samples which likely contain large number of degradation-related impurities (DRIs) with different polarities and charge properties. It is often a challenge to develop selective and robust high performance liquid chromatography (HPLC) methods for the efficient separation of all DRIs. In this study, an analytical quality by design (AQbD) approach was proposed for stability-indicating method development of cloxacillin. The structures, retention and UV characteristics rules of penicillins and their impurities were summarized and served as useful prior knowledge. Through quality risk assessment and screen design, 3 critical process parameters (CPPs) were defined, including 2 mixture variables (MVs) and 1 process variable (PV). A combined mixture-process variable (MPV) design was conducted to evaluate the 3 CPPs simultaneously and a response surface methodology (RSM) was used to achieve the optimal experiment parameters. A dual gradient elution was performed to change buffer pH, mobile-phase type and strength simultaneously. The design spaces (DSs) was evaluated using Monte Carlo simulation to give their possibility of meeting the specifications of CQAs. A Plackett-Burman design was performed to test the robustness around the working points and to decide the normal operating ranges (NORs). Finally, validation was performed following International Conference on Harmonisation (ICH) guidelines. To our knowledge, this is the first study of using MPV design and dual gradient elution to develop HPLC methods and improve separations for complex ionic samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Sequential Elution of Essential Oil Constituents during Steam Distillation of Hops (Humulus lupulus L.) and Influence on Oil Yield and Antimicrobial Activity.

    PubMed

    Jeliazkova, Ekaterina; Zheljazkov, Valtcho D; Kačániova, Miroslava; Astatkie, Tess; Tekwani, Babu L

    2018-06-07

    The profile and bioactivity of hops (Humulus lupulus L.) essential oil, a complex natural product extracted from cones via steam distillation, depends on genetic and environmental factors, and may also depend on extraction process. We hypothesized that compound mixtures eluted sequentially and captured at different timeframes during the steam distillation process of whole hop cones would have differential chemical and bioactivity profiles. The essential oil was collected sequentially at 8 distillation time (DT) intervals: 0-2, 2-5, 5-10, 10-30, 30-60, 60-120, 120-180, and 180-240 min. The control was a 4-h non-interrupted distillation. Nonlinear regression models described the DT and essential oil compounds relationship. Fractions yielded 0.035 to 0.313% essential oil, while control yielded 1.47%. The oil eluted during the first hour was 83.2%, 9.6% during the second hour, and only 7.2% during the second half of the distillation. Essential oil (EO) fractions had different chemical profile. Monoterpenes were eluted early, while sequiterpenes were eluted late. Myrcene and linalool were the highest in 0-2 min fraction, β-caryophyllene, β-copaene, β-farnesene, and α-humulene were highest in fractions from middle of distillation, whereas α- bergamotene, γ-muurolene, β- and α-selinene, γ- and δ-cadinene, caryophyllene oxide, humulne epoxide II, τ-cadinol, and 6-pentadecen-2-one were highest in 120-180 or 180-240 min fractions. The Gram-negative Escherichia coli was strongly inhibited by essential oil fractions from 2-5 min and 10-30 min, followed by oil fraction from 0-2 min. The strongest inhibition activity against Gram-negative Yersinia enterocolitica, and Gram-positive Clostridium perfringens, Enterococcus faecalis, and Staphylococcus aureus subs. aureus was observed with the control essential oil. This is the first study to describe significant activity of hops essential oils against Trypanosoma brucei, a parasitic protozoan that causes African trypanosomiasis (sleeping sickness in humans and nagana in other animals). Hops essential oil fractions or whole oil may be used as antimicrobial agents or for the development of new drugs.

  19. EVALUATION OF FACTORS IN THE ELUTION OF HYDROCORTISONE FROM PAPER CHROMATOGRAMS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ganis, F.M.; Hendrickson, M.W.; Giunta, P.D.

    An assessment was made of a number of variable factors which affect the recovery of hydrocortisone from eluted filter paper chromatographic fractions. Factors tested included time of elution, sample concentration, rinsing of eluting fractions and pre-washing of the filter paper. It was noted that a 50 mu g sample could be quantitatively recovered after a 15-minute elution time from a pre-washed filter paper fraction. The results were subjected to a statistical analysis and were found to be highly significant. (auth)

  20. Everolimus-eluting stents in interventional cardiology

    PubMed Central

    Townsend, Jacob C; Rideout, Phillip; Steinberg, Daniel H

    2012-01-01

    Bare metal stents have a proven safety record, but limited long-term efficacy due to in-stent restenosis. First-generation drug-eluting stents successfully countered the restenosis rate, but were hampered by concerns about their long-term safety. Second generation drug-eluting stents have combined the low restenosis rate of the first generation with improved long-term safety. We review the evolution of drug-eluting stents with a focus on the safety, efficacy, and unique characteristics of everolimus-eluting stents. PMID:22910420

  1. Method for the concentration and separation of actinides from biological and environmental samples

    DOEpatents

    Horwitz, E. Philip; Dietz, Mark L.

    1989-01-01

    A method and apparatus for the quantitative recover of actinide values from biological and environmental sample by passing appropriately prepared samples in a mineral acid solution through a separation column of a dialkyl(phenyl)-N,N-dialylcarbamoylmethylphosphine oxide dissolved in tri-n-butyl phosphate on an inert substrate which selectively extracts the actinide values. The actinide values can be eluted either as a group or individually and their presence quantitatively detected by alpha counting.

  2. Steady state preparative multiple dual mode counter-current chromatography: Productivity and selectivity. Theory and experimental verification.

    PubMed

    Kostanyan, Artak E; Erastov, Andrey A

    2015-08-07

    In the steady state (SS) multiple dual mode (MDM) counter-current chromatography (CCC), at the beginning of the first step of every cycle the sample dissolved in one of the phases is continuously fed into a CCC device over a constant time, not exceeding the run time of the first step. After a certain number of cycles, the steady state regime is achieved, where concentrations vary over time during each cycle, however, the concentration profiles of solutes eluted with both phases remain constant in all subsequent cycles. The objective of this work was to develop analytical expressions to describe the SS MDM CCC separation processes, which can be helpful to simulate and design these processes and select a suitable compromise between the productivity and the selectivity in the preparative and production CCC separations. Experiments carried out using model mixtures of compounds from the GUESSmix with solvent system hexane/ethyl acetate/methanol/water demonstrated a reasonable agreement between the predictions of the theory and the experimental results. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Accelerated in vitro release testing of implantable PLGA microsphere/PVA hydrogel composite coatings

    PubMed Central

    Shen, Jie; Burgess, Diane J.

    2011-01-01

    Dexamethasone loaded poly(lactic-co-glycolic acid) (PLGA) microsphere/PVA hydrogel composites have been investigated as an outer drug-eluting coating for implantable devices such as glucose sensors to counter negative tissue responses to implants. The objective of this study was to develop a discriminatory, accelerated in vitro release testing method for this drug-eluting coating using United States Pharmacopeia (USP) apparatus 4. Polymer degradation and drug release kinetics were investigated under “real-time” and accelerated conditions (i.e. extreme pH, hydro-alcoholic solutions and elevated temperatures). Compared to “real-time” conditions, the initial burst and lag phases were similar using hydro-alcoholic solutions and extreme pH conditions, while the secondary apparent zero-order release phase was slightly accelerated. Elevated temperatures resulted in a significant acceleration of dexamethasone release. The accelerated release data were able to predict “real-time” release when applying the Arrhenius equation. Microsphere batches with faster and slower release profiles were investigated under “real-time” and elevated temperature (60°C) conditions to determine the discriminatory ability of the method. The results demonstrated both the feasibility and the discriminatory ability of this USP apparatus 4 method for in vitro release testing of drug loaded PLGA microsphere/PVA hydrogel composites. This method may be appropriate for similar drug/device combination products and drug delivery systems. PMID:22016033

  4. Accelerated in vitro release testing of implantable PLGA microsphere/PVA hydrogel composite coatings.

    PubMed

    Shen, Jie; Burgess, Diane J

    2012-01-17

    Dexamethasone loaded poly(lactic-co-glycolic acid) (PLGA) microsphere/PVA hydrogel composites have been investigated as an outer drug-eluting coating for implantable devices such as glucose sensors to counter negative tissue responses to implants. The objective of this study was to develop a discriminatory, accelerated in vitro release testing method for this drug-eluting coating using United States Pharmacopeia (USP) apparatus 4. Polymer degradation and drug release kinetics were investigated under "real-time" and accelerated conditions (i.e. extreme pH, hydro-alcoholic solutions and elevated temperatures). Compared to "real-time" conditions, the initial burst and lag phases were similar using hydro-alcoholic solutions and extreme pH conditions, while the secondary apparent zero-order release phase was slightly accelerated. Elevated temperatures resulted in a significant acceleration of dexamethasone release. The accelerated release data were able to predict "real-time" release when applying the Arrhenius equation. Microsphere batches with faster and slower release profiles were investigated under "real-time" and elevated temperature (60°C) conditions to determine the discriminatory ability of the method. The results demonstrated both the feasibility and the discriminatory ability of this USP apparatus 4 method for in vitro release testing of drug loaded PLGA microsphere/PVA hydrogel composites. This method may be appropriate for similar drug/device combination products and drug delivery systems. Copyright © 2011 Elsevier B.V. All rights reserved.

  5. Theory of end-labeled free-solution electrophoresis: is the end effect important?

    PubMed

    Chubynsky, Mykyta V; Slater, Gary W

    2014-03-01

    In the theory of free-solution electrophoresis of a polyelectrolyte (such as the DNA) conjugated with a "drag-tag," the conjugate is divided into segments of equal hydrodynamic friction and its electrophoretic mobility is calculated as a weighted average of the mobilities of individual segments. If all the weights are assumed equal, then for an electrically neutral drag-tag, the elution time t is predicted to depend linearly on the inverse DNA length 1/M. While it is well-known that the equal-weights assumption is approximate and in reality the weights increase toward the ends, this "end effect" has been assumed to be small, since in experiments the t(1/M) dependence seems to be nearly perfectly linear. We challenge this assumption pointing out that some experimental linear fits do not extrapolate to the free (i.e. untagged) DNA elution time in the limit 1/M→0, indicating nonlinearity outside the fitting range. We show that a theory for a flexible polymer taking the end effect into account produces a nonlinear curve that, however, can be fitted with a straight line over a limited range of 1/M typical of experiments, but with a "wrong" intercept, which explains the experimental results without additional assumptions. We also study the influence of the flexibilities of the charged and neutral parts. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Antioxidant potential of polyphenols and tannins from burs of Castanea mollissima Blume.

    PubMed

    Zhao, Shan; Liu, Jie Yuan; Chen, Si Yu; Shi, Ling Ling; Liu, Yu Jun; Ma, Chao

    2011-10-12

    Spiny burs of Castanea mollissima Blume (Chinese chestnut) are usually discarded as industrial waste during post-harvesting processing. The objective of this study was to establish an extraction and isolation procedure for tannins from chestnut burs, and to assess their potential antioxidant activity. Aqueous ethanol solution was used as extraction solvent, and HPD 100 macroporous resin column was applied for isolation. The influence of solvent concentration in the extraction and elution process on extraction yield, tannins and polyphenols content, as well as antioxidant potential, including DPPH and ABTS radical scavenging ability, reducing power ability and cellular antioxidant ability were assessed. In both the extraction and isolation process, 50% aqueous ethanol led to superior total tannins and polyphenols content as well as significantly higher antioxidant activity. In addition, the antioxidant activity and the total tannins content in extracts and fractions had a positive linear correlation, and the predominant components responsible for antioxidant activities were characterized as hydrolysable tannins. To the best of our knowledge, this is the first report on the enrichment of tannins from burs of C. mollissim using macroporous resin chromatography, and to assess the cellular antioxidant activity of them.

  7. The use of carrier RNA to enhance DNA extraction from microfluidic-based silica monoliths.

    PubMed

    Shaw, Kirsty J; Thain, Lauren; Docker, Peter T; Dyer, Charlotte E; Greenman, John; Greenway, Gillian M; Haswell, Stephen J

    2009-10-12

    DNA extraction was carried out on silica-based monoliths within a microfluidic device. Solid-phase DNA extraction methodology was applied in which the DNA binds to silica in the presence of a chaotropic salt, such as guanidine hydrochloride, and is eluted in a low ionic strength solution, such as water. The addition of poly-A carrier RNA to the chaotropic salt solution resulted in a marked increase in the effective amount of DNA that could be recovered (25ng) compared to the absence of RNA (5ng) using the silica-based monolith. These findings confirm that techniques utilising nucleic acid carrier molecules can enhance DNA extraction methodologies in microfluidic applications.

  8. Precision control of eluted activity from a Sr/Rb generator for cardiac positron emission tomography.

    PubMed

    Klein, R; Adler, A; Beanlands, R S; deKemp, R A

    2004-01-01

    A rubidium-82 (/sup 82/Rb) elution system is described for use with clinical positron emission tomography. The system is self-calibrating with 1.4% repeatability, independent of generator activity and elution flow rate. Saline flow is switched between a /sup 82/Sr//sup 82/Rb generator and a bypass line to achieve a constant activity elution of /sup 82/Rb. In the present study, pulse width modulation (PWM) of a solenoid valve is compared to simple threshold control as a means to simulate a proportional valve. A predictive-corrective control algorithm is developed which produces a constant activity elution within the constraints of long feedback delay and short elution time. Accurate constant-activity elutions of 10-70% of the total generator activity were demonstrated using the threshold comparison control. The adaptive-corrective control of the PWM valve provided a substantial improvement in precision of the steady-state output.

  9. Method for enhanced accuracy in predicting peptides using liquid separations or chromatography

    DOEpatents

    Kangas, Lars J.; Auberry, Kenneth J.; Anderson, Gordon A.; Smith, Richard D.

    2006-11-14

    A method for predicting the elution time of a peptide in chromatographic and electrophoretic separations by first providing a data set of known elution times of known peptides, then creating a plurality of vectors, each vector having a plurality of dimensions, and each dimension representing the elution time of amino acids present in each of these known peptides from the data set. The elution time of any protein is then be predicted by first creating a vector by assigning dimensional values for the elution time of amino acids of at least one hypothetical peptide and then calculating a predicted elution time for the vector by performing a multivariate regression of the dimensional values of the hypothetical peptide using the dimensional values of the known peptides. Preferably, the multivariate regression is accomplished by the use of an artificial neural network and the elution times are first normalized using a transfer function.

  10. Direct enantioseparation of nitrogen-heterocyclic pesticides on cellulose-based chiral column by high-performance liquid chromatography.

    PubMed

    Chai, Tingting; Yang, Wenwen; Qiu, Jing; Hou, Shicong

    2015-01-01

    The enantiomeric separation of eight pesticides including bitertanol (), diclobutrazol (), fenbuconazole (), triticonazole (), imazalil (), triapenthenol (), ancymidol (), and carfentrazone-ethyl () was achieved, using normal-phase high-performance liquid chromatography on two cellulosed-based chiral columns. The effects of isopropanol composition from 2% to 30% in the mobile phase and column temperature from 5 to 40 °C were investigated. Satisfactory resolutions were obtained for bitertanol (), triticonazole (), imazalil () with the (+)-enantiomer eluted first and fenbuconazole () with the (-)-enantiomer eluted first on Lux Cellulose-2 and Lux Cellulose-3. (+)-Enantiomers of diclobutrazol () and triapenthenol () were first eluted on Lux Cellulose-2. (-)-Carfentrazone-ethyl () were eluted first on Lux Cellulose-2 and Lux Cellulose-3 with incomplete separation. Reversed elution orders were obtained for ancymidol (7). (+)-Ancymidol was first eluted on Lux Cellulose-2 while on Lux Cellulose-3 (-)-ancymidol was first eluted. The results of the elution order at different column temperatures suggested that column temperature did not affect the optical signals of the enantiomers. These results will be helpful to prepare and analyze individual enantiomers of chiral pesticides. © 2014 Wiley Periodicals, Inc.

  11. Isolation and characterization of Chinese standard fulvic acid sub-fractions separated from forest soil by stepwise elution with pyrophosphate buffer.

    PubMed

    Bai, Yingchen; Wu, Fengchang; Xing, Baoshan; Meng, Wei; Shi, Guolan; Ma, Yan; Giesy, John P

    2015-03-04

    XAD-8 adsorption technique coupled with stepwise elution using pyrophosphate buffers with initial pH values of 3, 5, 7, 9, and 13 was developed to isolate Chinese standard fulvic acid (FA) and then separated the FA into five sub-fractions: FApH3, FApH5, FApH7, FApH9 and FApH13, respectively. Mass percentages of FApH3-FApH13 decreased from 42% to 2.5%, and the recovery ratios ranged from 99.0% to 99.5%. Earlier eluting sub-fractions contained greater proportions of carboxylic groups with greater polarity and molecular mass, and later eluting sub-fractions had greater phenolic and aliphatic content. Protein-like components, as well as amorphous and crystalline poly(methylene)-containing components were enriched using neutral and basic buffers. Three main mechanisms likely affect stepwise elution of humic components from XAD-8 resin with pyrophosphate buffers including: 1) the carboxylic-rich sub-fractions are deprotonated at lower pH values and eluted earlier, while phenolic-rich sub-fractions are deprotonated at greater pH values and eluted later. 2) protein or protein-like components can be desorbed and eluted by use of stepwise elution as progressively greater pH values exceed their isoelectric points. 3) size exclusion affects elution of FA sub-fractions. Successful isolation of FA sub-fractions will benefit exploration of the origin, structure, evolution and the investigation of interactions with environmental contaminants.

  12. Isolation and Characterization of Chinese Standard Fulvic Acid Sub-fractions Separated from Forest Soil by Stepwise Elution with Pyrophosphate Buffer

    PubMed Central

    Bai, Yingchen; Wu, Fengchang; Xing, Baoshan; Meng, Wei; Shi, Guolan; Ma, Yan; Giesy, John P.

    2015-01-01

    XAD-8 adsorption technique coupled with stepwise elution using pyrophosphate buffers with initial pH values of 3, 5, 7, 9, and 13 was developed to isolate Chinese standard fulvic acid (FA) and then separated the FA into five sub-fractions: FApH3, FApH5, FApH7, FApH9 and FApH13, respectively. Mass percentages of FApH3-FApH13 decreased from 42% to 2.5%, and the recovery ratios ranged from 99.0% to 99.5%. Earlier eluting sub-fractions contained greater proportions of carboxylic groups with greater polarity and molecular mass, and later eluting sub-fractions had greater phenolic and aliphatic content. Protein-like components, as well as amorphous and crystalline poly(methylene)-containing components were enriched using neutral and basic buffers. Three main mechanisms likely affect stepwise elution of humic components from XAD-8 resin with pyrophosphate buffers including: 1) the carboxylic-rich sub-fractions are deprotonated at lower pH values and eluted earlier, while phenolic-rich sub-fractions are deprotonated at greater pH values and eluted later. 2) protein or protein-like components can be desorbed and eluted by use of stepwise elution as progressively greater pH values exceed their isoelectric points. 3) size exclusion affects elution of FA sub-fractions. Successful isolation of FA sub-fractions will benefit exploration of the origin, structure, evolution and the investigation of interactions with environmental contaminants. PMID:25735451

  13. Safety, feasibility, and efficacy of placement of steroid-eluting bioabsorbable sinus implants in the office setting: a prospective case series.

    PubMed

    Matheny, Keith E; Carter, Kenny B; Tseng, Ewen Y; Fong, Karen J

    2014-10-01

    The outcomes of endoscopic sinus surgery (ESS) for chronic rhinosinusitis (CRS) can be compromised by postoperative inflammation, recurrent polyposis, middle turbinate lateralization, and synechiae, often requiring subsequent interventions. A bioabsorbable steroid-eluting sinus implant placed in the operating room following ESS has been proven safe and effective in 2 randomized controlled trials and a subsequent meta-analysis, for its ability to preserve sinus patency, and reduce medical and surgical interventions. This trial sought to evaluate the safety, feasibility, and outcomes of implants placed in the office after achieving hemostasis. Twenty patients with CRS underwent ESS including bilateral ethmoidectomy. A steroid-eluting bioabsorbable implant was deployed into each ethmoid cavity in the office within 7 days after ESS. Endoscopic appearance of the ethmoid cavities was evaluated at 1 week, 2 weeks, and 4 weeks postoperatively by the operating surgeon and an independent blinded evaluator. Procedural tolerance was assessed at week 2 using a patient preference questionnaire. The 20-item Sino-Nasal Outcome Test (SNOT-20) questionnaire was completed at baseline, week 2, and week 4. In-office placement of steroid-eluting bioabsorbable implants was well tolerated, with 90% of patients very satisfied with the overall experience, and 80% very satisfied with the recovery process. At 1 month, there were no significant adhesions or frank polyposis, and middle turbinate lateralization was only 5%. Compared to baseline, ethmoid sinus inflammation was significantly reduced (p = 0.03), and the mean SNOT-20 score was significantly improved (p < 0.001). In-office placement of steroid-eluting bioabsorbable implants after achieving hemostasis was well tolerated and might improve local drug diffusion and surgical outcomes. © 2014 ARS-AAOA, LLC.

  14. Dispersive micro solid phase extraction (DMSPE) using polymer anion exchange (PAX) as the sorbent followed by UPLC-MS/MS for the rapid determination of four bisphenols in commercial edible oils.

    PubMed

    Xian, Yanping; Wu, Yuluan; Dong, Hao; Guo, Xindong; Wang, Bin; Wang, Li

    2017-09-29

    The present work presents a novel and rapid analytical method for the simultaneous analysis of bisphenol A (BPA), bisphenol B (BPB), bisphenol F (BPF) and bisphenol S (BPS) in edible oil based on dispersive micro solid phase extraction (DMSPE) for the first time followed by isotope dilution-ultra high performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS). The edible oil sample was dispersed by n-hexane and extracted with ammoniated methanol-water solution. Then the target analytes were dispersedly absorbed using the polymer anion exchange (PAX) as the sorbent and eluted by acidic methanol. After that, four bisphenols were separated on a C18 column by gradient elution with methanol and 0.05% ammonium hydroxide in water as mobile phase, detected by MS/MS under multiple reactions monitoring (MRM) mode and quantified by internal standard method. The PAX amounts, adsorption time, concentrations of formic acid in the elution solvent and volume of elution solvent for the DMSPE technique were optimized. The limit of detection and quantitation (LOD and LOQ), matrix effect, recovery and precision of the developed method were investigated. Results indicated that BPS and the rest three bisphenols displayed excellent linearity in the concentration ranges of 0.1-50μg/L and 0.5-250μg/L, respectively, with correlation coefficients (R 2 ) all larger than 0.998. Achieved MLODs (S/N=3) varied between 0.1-0.4μg/kg for all bisphenols. The mean recoveries at three spiked levels in edible oil were in the range of 87.3-108%. Intra-day precision (n=6) and inter-day precision (n=5) were <9% and <11%, respectively. This method is of rapid-and-simple pretreatment, accurate and sensitive, and suitable for the simultaneous determination of bisphenols in edible oil. Copyright © 2017. Published by Elsevier B.V.

  15. A rapid solid-phase extraction fluorometric method for thiamine and riboflavin in salmonid eggs

    USGS Publications Warehouse

    Zajicek, James L.; Tillitt, Donald E.; Brown, Scott B.; Brown, Lisa R.; Honeyfield, Dale C.; Fitzsimons, John D.

    2005-01-01

    A new method has been developed and successfully applied to the selective measurement of thiamine (nonphosphorylated), total thiamine (sum of thiamine, thiamine monophosphate [TMP], thiamine diphosphate [TDP], and thiamine triphosphate [TTP]), and potentially interfering riboflavin in acidic (2% trichloroacetic acid) extracts of selected salmonid and walleye egg samples. Acidic extracts of eggs were applied directly to end-capped C18, reversed-phase solid-phase extraction (SPE) columns and separated into three fractions by elution with mixtures of PO4 buffer (pH 2), methanol (10%), and acetonitrile (20%). All thiamine compounds recovered in the first two fractions were oxidized to their corresponding thiochromes with alkaline potassium hexacyanoferrate, and we measured the thiochrome fluorescence (excitation at 360 nm, emission at 460 nm) in a 96-well microplate reader. Riboflavin, recovered in third fraction (eluted with pH 2, 20% acetonitrile), was analyzed directly by measuring the fluorescence of this fraction (excitation at 450 nm, emission at 530 nm). Significant portions of the phosphate esters of thiamine (TMP, TDP, and presumably TTP), when present at low concentrations (< 10 nmol of total -thiamine per gram of egg), were not retained by the 100-mg SPE column, and were collected directly during sample loading and in a subsequent phosphoric acid rinse as fraction 1. Free thiamine (nonphosphorylated) and remaining portions of the TDP and TMP were then eluted in the second fraction with 10% methanol/PO4 buffer, whereas the un-ionized, relatively nonpolar riboflavin was eluted in the third fraction with 20% acetonitrile. This new method uses a traditional sample homogenization of egg tissue to extract thiamine compounds into 2% trichlororacetic acid solution; an inexpensive, commercially available SPE column; small amounts of sample (0.5-1 g); microliter volumes of solvents per sample; a traditional, relatively nonhazardous, oxidation of thiamine compounds to fluorescent thiochromes; and an ultraviolet-visible-wavelength-filter fluorometer for the measurements. ?? Copyright by the American Fisheries Society 2005.

  16. Gradient design for liquid chromatography using multi-scale optimization.

    PubMed

    López-Ureña, S; Torres-Lapasió, J R; Donat, R; García-Alvarez-Coque, M C

    2018-01-26

    In reversed phase-liquid chromatography, the usual solution to the "general elution problem" is the application of gradient elution with programmed changes of organic solvent (or other properties). A correct quantification of chromatographic peaks in liquid chromatography requires well resolved signals in a proper analysis time. When the complexity of the sample is high, the gradient program should be accommodated to the local resolution needs of each analyte. This makes the optimization of such situations rather troublesome, since enhancing the resolution for a given analyte may imply a collateral worsening of the resolution of other analytes. The aim of this work is to design multi-linear gradients that maximize the resolution, while fulfilling some restrictions: all peaks should be eluted before a given maximal time, the gradient should be flat or increasing, and sudden changes close to eluting peaks are penalized. Consequently, an equilibrated baseline resolution for all compounds is sought. This goal is achieved by splitting the optimization problem in a multi-scale framework. In each scale κ, an optimization problem is solved with N κ  ≈ 2 κ variables that are used to build the gradients. The N κ variables define cubic splines written in terms of a B-spline basis. This allows expressing gradients as polygonals of M points approximating the splines. The cubic splines are built using subdivision schemes, a technique of fast generation of smooth curves, compatible with the multi-scale framework. Owing to the nature of the problem and the presence of multiple local maxima, the algorithm used in the optimization problem of each scale κ should be "global", such as the pattern-search algorithm. The multi-scale optimization approach is successfully applied to find the best multi-linear gradient for resolving a mixture of amino acid derivatives. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Assessing the transport potential of polymeric nanocapsules developed for crop protection.

    PubMed

    Petosa, Adamo Riccardo; Rajput, Faraz; Selvam, Olivia; Öhl, Carolin; Tufenkji, Nathalie

    2017-03-15

    Nanotechnology is increasingly important in the agricultural sector, with novel products being developed to heighten crop yields and increase pesticide efficacy. Herein, the transport potential of different polymeric nanocapsules (nCAPs) developed as pesticide delivery vehicles was assessed in model soil systems. The nCAPs examined are (i) poly(acrylic acid)-based (nCAP1), (ii) poly(methacrylic acid)-ran-poly(ethyl acrylate) copolymer-based (nCAP2), (iii) poly(methacrylic acid-ran-styrene) copolymer-based (nCAP3), and (iv) poly(methacrylic acid-ran-butylmethacrylate)-based (nCAP4). nCAP mobility was examined in columns packed with agricultural loamy sand saturated with artificial porewater containing Ca 2+ and Mg 2+ cations (10 mM ionic strength, pH 6 and 8). Furthermore, the impact of (i) cation species, (ii) sand type, and (iii) ammonium polyphosphate fertilizer on the transport potential of a nanoformulation combining nCAP4 capsules and the pyrethroid bifenthrin (nCAP4-BIF) was examined and compared to a commercial bifenthrin formulation (Capture ® LFR). Although nCAP4-BIF and Capture ® LFR formulations were highly mobile in quartz sand saturated with 10 mM NaNO 3 (≥95% elution), they were virtually immobile in the presence of 10% ammonium polyphosphate fertilizer. The presence of Ca 2+ and Mg 2+ did not hinder nCAP4-BIF elution in quartz sand saturated with 10 mM standard CIPAC D synthetic porewater; however, limited Capture ® LFR transport (<10% elution) was observed under the same conditions. Capture ® LFR also exhibited limited mobility in the presence or absence of fertilizer in loamy sand saturated with divalent salt solutions, whereas nCAP4-BIF exhibited increased elution with time and enhanced transport upon the addition of fertilizer. Overall, nCAP4 is a promising delivery vehicle in pyrethroid nanoformulations such as nCAP4-BIF. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. Characterisation of cationic potato starch by asymmetrical flow field-flow fractionation. Influence of ionic strength and degree of substitution.

    PubMed

    Santacruz, Stalin

    2014-06-15

    The properties of a paper sheet depend on the absorption together with the physico-chemical properties of additives used in the paper processing. The effect of ionic strength and degree of substitution of cationic potato starch on the elution pattern of asymmetrical flow field-flow fractionation was analysed. The effect of starch derivatisation, in either dry or wet phase, was also investigated. Average molar mass showed no difference between the starches obtained from the two derivatisation processes. Apparent densities showed that dry cationic starch had higher density than wet cationic starch for a hydrodynamic radius between 50 and 100 nm. Elution times of native and three cationic starches increased when the ionic strength increased from 50 to 100mM. No differences in the molar mass among cationic starches with different degree of substitution suggested no degradation due to a derivatisation process. Large sample loads can be used at 100mM without overloading. Copyright © 2014 Elsevier Ltd. All rights reserved.

  19. [Determination of 49 drugs and 5 metabolites in drinking water samples using ultra-high performance liquid chromatography-electrospray ionization tandem mass spectrometry].

    PubMed

    Wang, Shuo; Zhang, Xiangming; Zhang, Jing; Shao, Bing; Li, Shuming

    2015-07-01

    A method for the determination of 54 drugs in drinking water samples was developed by using ultra-high performance liquid chromatography-electrospray ionization tandem mass spectrometry (UPLC-ESI MS/MS). The target drugs in drinking water samples were enriched and cleaned-up by HLB solid-phase extraction (SPE) cartridges and then eluted with 5 mL methanol. The elute was collected, concentrated under a gentle stream of nitrogen gas, diluted with 0.4 mL 0.1% formic acid solution, and analyzed by UPLC-ESI MS/MS. The separation of the 54 drugs was performed on an ACQUITY UPLC™ BEH C18 column using mobile phases of 0.1% formic acid and methanol by gradient elution. The multiple reaction monitoring (MRM) mode was employed in mass spectrometry acquisition. The matrix-matched external standard calibration was used for quantitation. The results showed that the average recoveries of the drugs in ground water, tap water and surface water were 58.7%-104.4%, 53.1%-109.5%, and 50.7%-118.8%, respectively, and the corresponding relative standard deviations (RSD, n=6) were 0.3%-12.8%, 1.0%-15.5%, and 0.4%-19.3%, respectively. The method quantification limits (MQL) for target compounds were in the range of 0.002-5.000 ng/L. The developed method was applied to analyze the water samples from Beijing. The results showed that 26 drugs were detected in ground water samples.

  20. Radiolabeling of DOTA-like conjugated peptides with generator-produced 68Ga and using NaCl-based cationic elution method

    PubMed Central

    Mueller, Dirk; Breeman, Wouter A P; Klette, Ingo; Gottschaldt, Michael; Odparlik, Andreas; Baehre, Manfred; Tworowska, Izabela; Schultz, Michael K

    2017-01-01

    Gallium-68 (68Ga) is a generator-produced radionuclide with a short half-life (t½ = 68 min) that is particularly well suited for molecular imaging by positron emission tomography (PET). Methods have been developed to synthesize 68Ga-labeled imaging agents possessing certain drawbacks, such as longer synthesis time because of a required final purification step, the use of organic solvents or concentrated hydrochloric acid (HCl). In our manuscript, we provide a detailed protocol for the use of an advantageous sodium chloride (NaCl)-based method for radiolabeling of chelator-modified peptides for molecular imaging. By working in a lead-shielded hot-cell system, 68Ga3+ of the generator eluate is trapped on a cation exchanger cartridge (100 mg, ∼8 mm long and 5 mm diameter) and then eluted with acidified 5 M NaCl solution directly into a sodium acetate-buffered solution containing a DOTA (1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid) or DOTA-like chelator-modified peptide. The main advantages of this procedure are the high efficiency and the absence of organic solvents. It can be applied to a variety of peptides, which are stable in 1 M NaCl solution at a pH value of 3–4 during reaction. After labeling, neutralization, sterile filtration and quality control (instant thin-layer chromatography (iTLC), HPLC and pH), the radiopharmaceutical can be directly administered to patients, without determination of organic solvents, which reduces the overall synthesis-to-release time. This procedure has been adapted easily to automated synthesis modules, which leads to a rapid preparation of 68Ga radiopharmaceuticals (12–16 min). PMID:27172166

  1. Combination of graphene oxide-based solid phase extraction and electro membrane extraction for the preconcentration of chlorophenoxy acid herbicides in environmental samples.

    PubMed

    Tabani, Hadi; Fakhari, Ali Reza; Shahsavani, Abolfath; Behbahani, Mohammad; Salarian, Mani; Bagheri, Akbar; Nojavan, Saeed

    2013-07-26

    Combination of different extraction methods is an interesting and debatable work in the field of sample preparation. In the current study, for the first time, solid phase extraction combined with electro membrane extraction (SPE-EME) was developed for ultra-preconcentration and determination of chlorophenoxy acid herbicides in environmental samples using capillary electrophoresis (CE). In the mentioned method, first, a 100mL of chlorophenoxy acid herbicides (2-methyl-4-chlorophenoxyacetic acid (MCPA), 2-(2,4-dichlorophenoxy) propanoic acid (2,4-DP) and 2-(4-chloro-2-methylphenoxy) propanoic acid (MCPP)) was passed through a column of graphene oxide as a solid phase, and then the adsorbed herbicides were eluted by 4.0mL of 8% acetic acid (HOAC) in methanol. Then, the elution solvent was evaporated and the herbicides residue was dissolved in 4.0mL of double distilled water (pH 9.0). Afterwards, the herbicides in 4.0mL of the aqueous solution were transferred to an EME glass vial. In the EME step, the herbicides were extracted from the sample solution into the basic acceptor solution (pH 13.0) under electrical potential, which was held inside the lumen of the fiber with 1-octanol as the supported liquid membrane (SLM). Under the optimized conditions, high enrichment factors were obtained in the range of 1950-2000. The limits of quantification (LOQs) and method detection limits (MDLs) were obtained in the range of 1.0-1.5 and 0.3-0.5ngmL(-1), respectively. Finally, the performance of the present method was evaluated for extraction and determination of chlorophenoxy acid herbicides in environmental samples. Copyright © 2013 Elsevier B.V. All rights reserved.

  2. Solid-phase based on-chip DNA purification through a valve-free stepwise injection of multiple reagents employing centrifugal force combined with a hydrophobic capillary barrier pressure.

    PubMed

    Zhang, Hainan; Tran, Hong Hanh; Chung, Bong Hyun; Lee, Nae Yoon

    2013-03-21

    In this paper, we demonstrate a simple technique for sequentially introducing multiple sample liquids into microchannels driven by centrifugal force combined with a hydrophobic barrier pressure and apply the technique for performing solid-phase based on-chip DNA purification. Three microchannels with varying widths, all equipped with independent sample reservoirs at the inlets, were fabricated on a hydrophobic elastomer, poly(dimethylsiloxane) (PDMS). First, glass beads were packed inside the reaction chamber, and a whole cell containing the DNA extract was introduced into the widest channel by applying centrifugal force for physical adsorption of the DNA onto the glass beads. Next, washing and elution solutions were sequentially introduced into the intermediate and narrowest microchannels, respectively, by gradually increasing the amount of centrifugal force. Through a precise manipulation of the centrifugal force, the DNA adsorbed onto the glass beads was successfully washed and eluted in a continuous manner without the need to introduce each solution manually. A stepwise injection of liquids was successfully demonstrated using multiple ink solutions, the results of which corresponded well with the theoretical analyses. As a practical application, the D1S80 locus of human genomic DNA, which is widely used for forensic purposes, was successfully purified using the microdevice introduced in this study, as demonstrated through successful target amplification. This will pave the way for the construction of a control-free valve system for realizing on-chip DNA purification, which is one of the most labor-intensive and hard-to-miniaturize components, on a greatly simplified and miniaturized platform employing hydrophobic PDMS.

  3. Radiolabeling of DOTA-like conjugated peptides with generator-produced (68)Ga and using NaCl-based cationic elution method.

    PubMed

    Mueller, Dirk; Breeman, Wouter A P; Klette, Ingo; Gottschaldt, Michael; Odparlik, Andreas; Baehre, Manfred; Tworowska, Izabela; Schultz, Michael K

    2016-06-01

    Gallium-68 ((68)Ga) is a generator-produced radionuclide with a short half-life (t½ = 68 min) that is particularly well suited for molecular imaging by positron emission tomography (PET). Methods have been developed to synthesize (68)Ga-labeled imaging agents possessing certain drawbacks, such as longer synthesis time because of a required final purification step, the use of organic solvents or concentrated hydrochloric acid (HCl). In our manuscript, we provide a detailed protocol for the use of an advantageous sodium chloride (NaCl)-based method for radiolabeling of chelator-modified peptides for molecular imaging. By working in a lead-shielded hot-cell system,(68)Ga(3+) of the generator eluate is trapped on a cation exchanger cartridge (100 mg, ∼8 mm long and 5 mm diameter) and then eluted with acidified 5 M NaCl solution directly into a sodium acetate-buffered solution containing a DOTA (1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid) or DOTA-like chelator-modified peptide. The main advantages of this procedure are the high efficiency and the absence of organic solvents. It can be applied to a variety of peptides, which are stable in 1 M NaCl solution at a pH value of 3-4 during reaction. After labeling, neutralization, sterile filtration and quality control (instant thin-layer chromatography (iTLC), HPLC and pH), the radiopharmaceutical can be directly administered to patients, without determination of organic solvents, which reduces the overall synthesis-to-release time. This procedure has been adapted easily to automated synthesis modules, which leads to a rapid preparation of (68)Ga radiopharmaceuticals (12-16 min).

  4. Metallic Limus-Eluting Stents Abluminally Coated with Biodegradable Polymers: Angiographic and Clinical Comparison of a Novel Ultra-Thin Sirolimus Stent Versus Biolimus Stent in the DESTINY Randomized Trial.

    PubMed

    Lemos, Pedro A; Abizaid, Alexandre A C; Meireles, George C; Sarmento-Leite, Rogério; Prudente, Mauricio; Cantarelli, Marcelo; Dourado, Adriano D; Mariani, Jose; Perin, Marco A; Costantini, Costantino; Costa, Ricardo A; Costa, José Ribamar; Chamie, Daniel; Campos, Carlos A; Ribeiro, Expedito

    2015-12-01

    To evaluate the outcomes of patients treated with a new drug-eluting stent formulation with low doses of sirolimus, built in an ultra-thin-strut platform coated with biodegradable abluminal coating. This study is a randomized trial that tested the main hypothesis that the angiographic late lumen loss of the novel sirolimus-eluting stent is noninferior compared with commercially available biolimus-eluting stent. A final study population comprising 170 patients with one or two de novo lesions was randomized in the ratio 2:1 for sirolimus-eluting stent or biolimus-eluting stent, respectively. The primary endpoint was 9-month angiographic in-stent late lumen loss. Adverse clinical events were prospectively collected for 1 year. After 9 months, the novel sirolimus-eluting stent was shown noninferior compared with the biolimus stent for the primary endpoint (angiographic in-stent late lumen loss: 0.20 ± 0.29 mm vs. 0.15 ± 0.20 mm, respectively; P value for noninferiority <0.001). The 1-year incidence of death, myocardial infarction, repeat revascularization, and stent thrombosis remained low and not significantly different between the groups. The present randomized trial demonstrates that the tested novel sirolimus-eluting stent was angiographically noninferior in comparison with a last-generation biolimus-eluting stent. © 2015 John Wiley & Sons Ltd.

  5. Increasing Flexibility in Two-Dimensional Liquid Chromatography by Pulsed Elution of the First Dimension: A Proof of Concept.

    PubMed

    Jakobsen, Simon S; Christensen, Jan H; Verdier, Sylvain; Mallet, Claude R; Nielsen, Nikoline J

    2017-09-05

    This work demonstrates the development of an online two-dimensional liquid chromatography (2D-LC) method where the first dimension column is eluted by a sequence of pulses of increasing eluotropic strength generated by the LC pumps (pulsed-elution 2D-LC). Between the pulses, the first dimension is kept in a no-elution state using low eluent strength. The eluate from the first dimension is actively modulated using trap columns and subsequently analyzed in the second dimension. We demonstrate that by tuning the length and eluotropic strength of the pulses, peaks with retention factors in water, k w , above 150 can be manipulated to elute in 3-4 pulses. The no-elution state can be kept for 1-10 min with only minor changes as to which and how many pulses the peaks elute in. Pulsed-elution 2D-LC combined with active modulation tackles three of the main challenges encountered in 2D-LC and specifically online comprehensive 2D-LC: undersampling, difficulties in refocusing, and lack of flexibility in the selection of column dimensions and flow rates because the two dimensions constrain each other. The pulsed-elution 2D-LC was applied for the analysis of a basic fraction of vacuum gas oil. Peak capacity was 4018 for a 540 min analysis and 4610 for a 1040 min analysis.

  6. Exploring doxorubicin localization in eluting TiO2 nanotube arrays through fluorescence correlation spectroscopy analysis.

    PubMed

    De Santo, Ilaria; Sanguigno, Luigi; Causa, Filippo; Monetta, Tullio; Netti, Paolo A

    2012-11-07

    Drug elution properties of TiO(2) nanotube arrays have been largely investigated by means of solely macroscopic observations. Controversial elution performances have been reported so far and a clear comprehension of these phenomena is still missing as a consequence of a lack of molecular investigation methods. Here we propose a way to discern drug elution properties of nanotubes through the evaluation of drug localization by Fluorescence Correlation Spectroscopy (FCS) analysis. We verified this method upon doxorubicin elution from differently loaded TiO(2) nanotubes. Diverse elution profiles were obtained from nanotubes filled by soaking and wet vacuum impregnation methods. Impregnated nanotubes controlled drug diffusion up to thirty days, while soaked samples completed elution in seven days. FCS analysis of doxorubicin motion in loaded nanotubes clarified that more than 90% of drugs dwell preferentially in inter-nanotube spaces in soaked samples due to decorrelation in a 2D fashion, while a 97% fraction of molecules showed 1D mobility ascribable to displacements along the nanotube vertical axis of wet vacuum impregnated nanotubes. The diverse drug localizations inferred from FCS measurements, together with distinct drug-surface interaction strengths resulting from diverse drug filling techniques, could explain the variability in elution kinetics.

  7. Variational Theory of Motion of Curved, Twisted and Extensible Elastic Rods

    DTIC Science & Technology

    1993-01-18

    nonlinear theory such as questions of existence of solutions and global behavior have been carried out by Antman (1976). His basic work entitled "The...Aerosp. Ens. Q017/018 16 REFERENCES Antman , S.S., "Ordinary Differential Equations of Non-Linear ElastIcity 1: Foundatious of the Theories of Non-Linearly...Elutic rods and Shells," A.R.M.A. 61 (1976), 307-351. Antman , S.S., "The Theory of Rods", Handbuch der Physik, Vol. Vla/2, Springer-Verlq, Berlin

  8. Method for the concentration and separation of actinides from biological and environmental samples

    DOEpatents

    Horwitz, E.P.; Dietz, M.L.

    1989-05-30

    A method and apparatus for the quantitative recover of actinide values from biological and environmental sample by passing appropriately prepared samples in a mineral acid solution through a separation column of a dialkyl(phenyl)-N,N-dialylcarbamoylmethylphosphine oxide dissolved in tri-n-butyl phosphate on an inert substrate which selectively extracts the actinide values. The actinide values can be eluted either as a group or individually and their presence quantitatively detected by alpha counting. 3 figs.

  9. Determination of soluble bromine in an extra-high-pressure mercury discharge lamp by sodium hydroxide decomposition-suppressed ion chromatography.

    PubMed

    Mitsumata, Hiroshi; Mori, Toshio; Maeda, Tatsuo; Kita, Yoshiyuki; Kohatsu, Osamu

    2006-02-01

    We have established a simple method for assaying the quantity of soluble bromine in the discharge tubes of an extra-high-pressure mercury discharge lamp. Each discharge tube is destroyed in 5 ml of 10 mM sodium hydroxide, and the recovered sodium hydroxide solution is analyzed by suppressed-ion chromatography using gradient elution. We have clarified that this method can assay less than 1 microg of soluble bromine in a discharge tube.

  10. Antiquarian books as source of environment historical water data.

    PubMed

    Schram, Jürgen; Schneider, Mario; Horst, Rasmus; Thieme, Hagen

    2009-05-01

    Historical environment considerations are inevitable also for modern environmental analysis. They alone allow evaluation of anthropogenic impact into the environment. To receive information about the historical environment situation in inhabited regions, we approached this task by examining historical well dated and locatable products of the Homo faber. The work introduced here uses books as a source of environment historical data specially for the environmental compartment of water. The paper of historical books, dated by their printing and allocated by their watermark(1) (Wasserzeichensammlung Piccard, Piccard online, Hauptstaatsarchiv Stuttgart, ) is a trap for traces of heavy metals contaminating their production water in historical times. Great amounts of water were brought into contact with the paper pulp in the historical paper mill process. The cellulose of the pulp acts as an ion exchange material for heavy metals, forming a dynamic equilibrium. A well defined pulp production process, starting with used clothes, allows estimation of the concentration of historical heavy metals (Cu(2+), Pb(2+), Zn(2+), Cd(2+)) in the production water (river water). Ancient papers from well dated books are eluted without destruction of their paper and the resulting solution is analysed by ETAAS and inverse stripping voltammetry to determine the historical impact of metals. Afterwards in a flow system the eluted paper spot is equilibrated with different concentrations of heavy metals (Cu(2+), Pb(2+), Zn(2+), Cd(2+)) to plot the adsorption isotherm of that very spot. Both data together allows a calculation of the heavy metal content of the historical river. For different waters of Germany and the Netherlands of the 16th-18th Century the heavy metal load could be estimated. The resulting concentrations were mostly similar to the level of modern surface waters, but in the case of the Dutch waters of the 17th Century, they were e.g. for Pb(2+) significantly higher than modern values.

  11. Liquid chromatography of polymers under limiting conditions of desorption II. Tandem injection and quantitative molar mass determination.

    PubMed

    Snauko, Marián; Berek, Dusan

    2005-11-11

    Liquid chromatography under limiting conditions of desorption (LC LCD) is a method which allows molar mass independent elution of various synthetic polymers. A narrow, slowly moving zone of small molecules, which promotes full adsorption of one kind of polymer species within column (an adsorli) acts as an impermeable barrier for the fast moving macromolecules. The latter accumulate on the barrier edge and elute nearly in total volume of liquid within column. At the same time, transport of less adsorptive macromolecules is not hampered so that these are eluted in the size exclusion (SEC) mode. As result, polymers differing in their polarity and adsorptivity can be easily separated without molar mass interference. Three methods of barrier creation are discussed and compared. It is shown that a fraction of sample may elute unretained if the adsorli sample solvent is used as a barrier in connection with a narrow-pore column packing. One part of excluded macromolecules likely breaks-out from the adsorli zone and this results in partial loss of sample and distortion of the LC LCD peaks. This problem can be avoided if the adsorli zone is injected immediately before sample solution. Applicability of the LC LCD method for polymer separation has been demonstrated with a model mixture of poly(methyl methacrylate) (adsorbing polymer) and polystyrene (non adsorbing polymer) using bare silica gel as a column packing with a combination of tetrahydrofuran (a desorption promoting liquid -a desorli) and toluene (adsorli). It has been shown that the LC LCD procedure with tandem injection allows simple and fast discrimination of polymer blend components with good repeatability and high sample recovery. For quantitative determination of molar masses of both LC LCD and SEC eluted polymers, an additional size exclusion chromatographic column can be applied either in a conventional way or in combination with a multi-angle light scattering detector. A single eluent is used in the latter column, which separates the mixed mobile phase, system peaks and the desorli zone from the polymer peaks so that measurements are free from disturbances caused by the changing eluent composition. The resulting LC LCD x SEC procedure has been successfully applied to poly(methyl methacrylate) samples.

  12. Purification of anti-Japanese encephalitis virus monoclonal antibody by ceramic hydroxyapatite chromatography without proteins A and G.

    PubMed

    Saito, Maiko; Kurosawa, Yae; Okuyama, Tsuneo

    2012-02-01

    Antibody purification using proteins A and G has been a standard method for research and industrial processes. The conventional method, however, includes a three-step process, including buffer exchange, before chromatography. In addition, proteins A and G require low pH elution, which causes antibody aggregation and inactivates the antibody's immunity. This report proposes a two-step method using hydroxyapatite chromatography and membrane filtration, without proteins A and G. This novel method shortens the running time to one-third the conventional method for each cycle. Using our two-step method, 90.2% of the monoclonal antibodies purified were recovered in the elution fraction, the purity achieved was >90%, and most of the antigen-specific activity was retained. This report suggests that the two-step method using hydroxyapatite chromatography and membrane filtration should be considered as an alternative to purification using proteins A and G.

  13. Nanofiber adsorbents for high productivity continuous downstream processing.

    PubMed

    Hardick, Oliver; Dods, Stewart; Stevens, Bob; Bracewell, Daniel G

    2015-11-10

    An ever increasing focus is being placed on the manufacturing costs of biotherapeutics. The drive towards continuous processing offers one opportunity to address these costs through the advantages it offers. Continuous operation presents opportunities for real-time process monitoring and automated control with potential benefits including predictable product specification, reduced labour costs, and integration with other continuous processes. Specifically to chromatographic operations continuous processing presents an opportunity to use expensive media more efficiently while reducing their size and therefore cost. Here for the first time we show how a new adsorbent material (cellulosic nanofibers) having advantageous convective mass transfer properties can be combined with a high frequency simulated moving bed (SMB) design to provide superior productivity in a simple bioseparation. Electrospun polymeric nanofiber adsorbents offer an alternative ligand support surface for bioseparations. Their non-woven fiber structure with diameters in the sub-micron range creates a remarkably high surface area material that allows for rapid convective flow operations. A proof of concept study demonstrated the performance of an anion exchange nanofiber adsorbent based on criteria including flow and mass transfer properties, binding capacity, reproducibility and life-cycle performance. Binding capacities of the DEAE adsorbents were demonstrated to be 10mg/mL, this is indeed only a fraction of what is achievable from porous bead resins but in combination with a very high flowrate, the productivity of the nanofiber system is shown to be significant. Suitable packing into a flow distribution device has allowed for reproducible bind-elute operations at flowrates of 2,400 cm/h, many times greater than those used in typical beaded systems. These characteristics make them ideal candidates for operation in continuous chromatography systems. A SMB system was developed and optimised to demonstrate the productivity of nanofiber adsorbents through rapid bind-elute cycle times of 7s which resulted in a 15-fold increase in productivity compared with packed bed resins. Reproducible performance of BSA purification was demonstrated using a 2-component protein solution of BSA and cytochrome c. The SMB system exploits the advantageous convective mass transfer properties of nanofiber adsorbents to provide productivities much greater than those achievable with conventional chromatography media. Copyright © 2015 The Authors. Published by Elsevier B.V. All rights reserved.

  14. Stent Thrombosis With Drug-Eluting Stents and Bioresorbable Scaffolds: Evidence From a Network Meta-Analysis of 147 Trials.

    PubMed

    Kang, Si-Hyuck; Chae, In-Ho; Park, Jin-Joo; Lee, Hak Seung; Kang, Do-Yoon; Hwang, Seung-Sik; Youn, Tae-Jin; Kim, Hyo-Soo

    2016-06-27

    This study sought to perform a systematic review and network meta-analysis to compare the relative safety and efficacy of contemporary DES and BVS. To improve outcomes of patients undergoing percutaneous coronary revascularization, there have been advances in the design of drug-eluting stents (DES), including the development of drug-eluting bioresorbable vascular scaffolds (BVS). Prospective, randomized, controlled trials comparing bare-metal stents (BMS), paclitaxel-eluting stents (PES), sirolimus-eluting stents (SES), Endeavor zotarolimus-eluting stents (E-ZES), cobalt-chromium (CoCr) everolimus-eluting stents (EES), platinum-chromium (PtCr)-EES, biodegradable polymer (BP)-EES, Resolute zotarolimus-eluting stents (R-ZES), BP biolimus-eluting stents (BP-BES), hybrid sirolimus-eluting stents (H [Orsiro]-SES), polymer-free sirolimus- and probucol-eluting stents, or BVS were searched in online databases. The primary endpoint was definite or probable stent thrombosis at 1 year. A total of 147 trials including 126,526 patients were analyzed in this study. All contemporary DES were superior to BMS and PES in terms of definite or probable stent thrombosis at 1 year. CoCr-EES, PtCr-EES, and H-SES were associated with significantly lower risk than BVS. CoCr-EES and H-SES were superior to SES and BP-BES. The risk of myocardial infarction was significantly lower with H-SES than with BVS. There were no significant differences regarding all-cause or cardiac mortality. Contemporary devices including BVS showed comparably low risks of repeat revascularization. Contemporary DES, including biocompatible DP-DES, BP-DES, and polymer-free DES, showed a low risk of definite or probable stent thrombosis at 1 year. BVS had an increased risk of device thrombosis compared with CoCr-EES, PtCr-EES, and H-SES. Data from extended follow-up are warranted to confirm the long-term safety of contemporary coronary devices. Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  15. Evaluation of differences between dual salt-pH gradient elution and mono gradient elution using a thermodynamic model: Simultaneous separation of six monoclonal antibody charge and size variants on preparative-scale ion exchange chromatographic resin.

    PubMed

    Lee, Yi Feng; Jöhnck, Matthias; Frech, Christian

    2018-02-21

    The efficiencies of mono gradient elution and dual salt-pH gradient elution for separation of six mAb charge and size variants on a preparative-scale ion exchange chromatographic resin are compared in this study. Results showed that opposite dual salt-pH gradient elution with increasing pH gradient and simultaneously decreasing salt gradient is best suited for the separation of these mAb charge and size variants on Eshmuno ® CPX. Besides giving high binding capacity, this type of opposite dual salt-pH gradient also provides better resolved mAb variant peaks and lower conductivity in the elution pools compared to single pH or salt gradients. To have a mechanistic understanding of the differences in mAb variants retention behaviors of mono pH gradient, parallel dual salt-pH gradient, and opposite dual salt-pH gradient, a linear gradient elution model was used. After determining the model parameters using the linear gradient elution model, 2D plots were used to show the pH and salt dependencies of the reciprocals of distribution coefficient, equilibrium constant, and effective ionic capacity of the mAb variants in these gradient elution systems. Comparison of the 2D plots indicated that the advantage of opposite dual salt-pH gradient system with increasing pH gradient and simultaneously decreasing salt gradient is the noncontinuous increased acceleration of protein migration. Furthermore, the fitted model parameters can be used for the prediction and optimization of mAb variants separation in dual salt-pH gradient and step elution. © 2018 American Institute of Chemical Engineers Biotechnol. Prog., 2018. © 2018 American Institute of Chemical Engineers.

  16. Synthesis and characterization of a molecularly imprinted polymer for the isolation of the 16 US-EPA priority polycyclic aromatic hydrocarbons (PAHs) in solution.

    PubMed

    Ncube, Somandla; Kunene, Phumlile; Tavengwa, Nikita T; Tutu, Hlanganani; Richards, Heidi; Cukrowska, Ewa; Chimuka, Luke

    2017-09-01

    A smart sorbent consisting of benzo[k]fluoranthene-imprinted and indeno[1 2 3-cd]pyrene-imprinted polymers mixed at 1:1 (w/w) was successfully screened from several cavity-tuning experiments and used in the isolation of polycyclic aromatic hydrocarbons from spiked solution. The polymer mixture showed high cross selectivity and affinity towards all the 16 US-EPA priority polycyclic aromatic hydrocarbons. The average extraction efficiency from a cyclohexane solution was 65 ± 13.3% (n = 16, SD). Batch adsorption and kinetic studies confirmed that the binding of polycyclic aromatic hydrocarbons onto the polymer particles resulted in formation of a monolayer and that the binding process was the rate limiting step. The imprinted polymer performance studies confirmed that the synthesized polymer had an imprinting efficiency of 103.9 ± 3.91% (n = 3, SD). A comparison of the theoretical number of cavities and the experimental binding capacity showed that the overall extent of occupation of the imprinted cavities in the presence of excess polycyclic aromatic hydrocarbons was 128 ± 6.45% (n = 3, SD). The loss of selectivity was estimated at 2.9% with every elution cycle indicating that the polymer can be re-used several times with limited loss of selectivity and sensitivity. The polymer combination has shown to be an effective adsorbent that can be used to isolate all the 16 US-EPA priority polycyclic aromatic hydrocarbons in solution. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Development and validation of a bioanalytical method for the simultaneous determination of heroin, its main metabolites, naloxone and naltrexone by LC-MS/MS in human plasma samples: Application to a clinical trial of oral administration of a heroin/naloxone formulation.

    PubMed

    Moreno-Vicente, Raquel; Fernández-Nieva, Zuriñe; Navarro, Arantza; Gascón-Crespí, Irene; Farré-Albaladejo, Magí; Igartua, Manuela; Hernández, Rosa María; Pedraz, José Luis

    2015-10-10

    A bioanalytical method using high-performance liquid chromatography-tandem mass spectrometry (LC-MS/MS) was developed and validated for simultaneous quantification of heroin, its main metabolites and naloxone. In addition, naltrexone was detected qualitatively. This method was used to analyse human plasma samples from a clinical trial after oral administration of a heroin/naloxone formulation in healthy volunteers. O-methylcodeine was used as an internal standard. Samples were kept in an ice-bath during their processing to minimize the degradation of heroin. A short methodology based on protein precipitation with methanol was used for sample preparation. After protein precipitation, only the addition of a formic acid solution was needed to elute heroin, 6-monoacetylmorphine, morphine, naloxone and naltrexone. Morphine metabolites were evaporated to dryness and reconstituted in a formic acid solution. Chromatographic separation was achieved at 35 °C on an X-Bridge Phenyl column (150 × 4.6 mm, 5 μm) using a gradient elution with a mobile phase of ammonium formate buffer at pH 3.0 and formic acid in acetonitrile. The run time was 8 min. The analytes were monitored using a triple quadrupole mass spectrometer with positive electrospray ionization (ESI+) in multiple reaction monitoring (MRM) mode. The method was found to be linear in a concentration range of 10-2000 ng/mL for M3G and 10-1000 ng/mL for the rest of compounds. Quality controls showed accurate values between -3.6% and 4.0% and intra- and inter-day precisions were below 11.5% for all analytes. The overall recoveries were approximately 100% for all analytes including the internal standard. A rapid, specific, precise and simple method was developed for the determination of heroin, its metabolites, naloxone and naltrexone in human plasma. This method was successfully applied to a clinical trial in 12 healthy volunteers. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. Differential expression and elution behavior of basic 7S globulin among cultivars under hot water treatment of soybean seeds.

    PubMed

    Fujiwara, Keigo; Cabanos, Cerrone; Toyota, Kenji; Kobayashi, Yasunori; Maruyama, Nobuyuki

    2014-06-01

    Basic 7S globulin (Bg7S), which accumulates in mature soybean (Glycine max) seeds, is an extracellular matrix protein. A large amount of Bg7S is synthesized de novo and is eluted from soybean seeds when immersed in 50-60°C water (hot water treatment, HWT). However, the Bg7S elution mechanism remains unclear. Under HWT, the seeds probably undergo heat stress and flooding stress. To obtain fundamental knowledge related to how Bg7S is eluted from hot-water-treated seeds, this study compared Bg7S elution among soybean cultivars having different flooding tolerance during pre-germination. The amounts of Bg7S eluted from seeds varied significantly among cultivars. Elution was suppressed by seed coats regarded as preventing the leakage of seed contents by rapid water imbibition. Furthermore, Bg7S expression levels differed among cultivars, although the difference did not result from any variation in Bg7S promoter sequences. However, the expression levels of Bg7S under HWT were not associated with the flooding tolerance level. Immunoelectron microscopy revealed that the Bg7S accumulated in the intercellular space of hot-water-treated seeds. Plasma membrane shrinkage was observed. The main proteins eluted from seeds under HWT were located in the extracellular space. This study clarified the mechanism of Bg7S elution from seeds under HWT. Copyright © 2013 The Society for Biotechnology, Japan. Published by Elsevier B.V. All rights reserved.

  19. Demonstration of a strategy for product purification by high-gradient magnetic fishing: recovery of superoxide dismutase from unconditioned whey.

    PubMed

    Meyer, Andrea; Hansen, Dennis B; Gomes, Cláudia S G; Hobley, Timothy J; Thomas, Owen R T; Franzreb, Matthias

    2005-01-01

    A systematic approach for the design of a bioproduct recovery process employing magnetic supports and the technique of high-gradient magnetic fishing (HGMF) is described. The approach is illustrated for the separation of superoxide dismutase (SOD), an antioxidant protein present in low concentrations (ca. 0.15-0.6 mg L(-1)) in whey. The first part of the process design consisted of ligand screening in which metal chelate supports charged with copper(II) ions were found to be the most suitable. The second stage involved systematic and sequential optimization of conditions for the following steps: product adsorption, support washing, and product elution. Next, the capacity of a novel high-gradient magnetic separator (designed for biotechnological applications) for trapping and holding magnetic supports was determined. Finally, all of the above elements were assembled to deliver a HGMF process for the isolation of SOD from crude sweet whey, which consisted of (i) binding SOD using Cu2+ -charged magnetic metal chelator particles in a batch reactor with whey; (ii) recovery of the "SOD-loaded" supports by high-gradient magnetic separation (HGMS); (iii) washing out loosely bound and entrained proteins and solids; (iv) elution of the target protein; and (v) recovery of the eluted supports from the HGMF rig. Efficient recovery of SOD was demonstrated at approximately 50-fold increased scale (cf magnetic rack studies) in three separate HGMF experiments, and in the best of these (run 3) an SOD yield of >85% and purification factor of approximately 21 were obtained.

  20. A continuum theory for multicomponent chromatography modeling.

    PubMed

    Pfister, David; Morbidelli, Massimo; Nicoud, Roger-Marc

    2016-05-13

    A continuum theory is proposed for modeling multicomponent chromatographic systems under linear conditions. The model is based on the description of complex mixtures, possibly involving tens or hundreds of solutes, by a continuum. The present approach is shown to be very efficient when dealing with a large number of similar components presenting close elution behaviors and whose individual analytical characterization is impossible. Moreover, approximating complex mixtures by continuous distributions of solutes reduces the required number of model parameters to the few ones specific to the characterization of the selected continuous distributions. Therefore, in the frame of the continuum theory, the simulation of large multicomponent systems gets simplified and the computational effectiveness of the chromatographic model is thus dramatically improved. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Update on the everolimus-eluting coronary stent system: results and implications from the SPIRIT clinical trial program

    PubMed Central

    Kirchner, R Michael; Abbott, J Dawn

    2009-01-01

    Drug-eluting stents (DES) have had a major impact in interventional cardiology. Compared to bare metal stents, they significantly reduce restenosis and the need for target vessel revascularization. Four DES are available in the US, the first-generation sirolimus-eluting (Cypher®) and paclitaxel-eluting (Taxus®) stents and later approved second-generation everolimus-eluting (Xience V®) and zotarolimus-eluting (Endeavor®) stents. The Xience V stent was approved on the basis of clinical efficacy and safety data from 3 studies in the SPIRIT clinical trial program. Within this trial series, the Xience V was superior to its bare metal stent counterpart, the Vision® stent, and noninferior to the paclitaxel-eluting stent for target vessel failure at 9 months. This review provides a comprehensive assessment of the data derived from both the pre- and post-approval randomized controlled trials and registry studies of Xience V that comprise the SPIRIT clinical trial program including recently published mid-term outcomes. The implications of the results in terms of interventional practice will be discussed. PMID:20057901

  2. Optimization of elution salt concentration in stepwise elution of protein chromatography using linear gradient elution data. Reducing residual protein A by cation-exchange chromatography in monoclonal antibody purification.

    PubMed

    Ishihara, Takashi; Kadoya, Toshihiko; Endo, Naomi; Yamamoto, Shuichi

    2006-05-05

    Our simple method for optimization of the elution salt concentration in stepwise elution was applied to the actual protein separation system, which involves several difficulties such as detection of the target. As a model separation system, reducing residual protein A by cation-exchange chromatography in human monoclonal antibody (hMab) purification was chosen. We carried out linear gradient elution experiments and obtained the data for the peak salt concentration of hMab and residual protein A, respectively. An enzyme-linked immunosorbent assay was applied to the measurement of the residual protein A. From these data, we calculated the distribution coefficient of the hMab and the residual protein A as a function of salt concentration. The optimal salt concentration of stepwise elution to reduce the residual protein A from the hMab was determined based on the relationship between the distribution coefficient and the salt concentration. Using the optimized condition, we successfully performed the separation, resulting in high recovery of hMab and the elimination of residual protein A.

  3. Determination of water-soluble forms of oxalic and formic acids in soils by ion chromatography

    NASA Astrophysics Data System (ADS)

    Karicheva, E.; Guseva, N.; Kambalina, M.

    2016-03-01

    Carboxylic acids (CA) play an important role in the chemical composition origin of soils and migration of elements. The content of these acids and their salts is one of the important characteristics for agrochemical, ecological, ameliorative and hygienic assessment of soils. The aim of the article is to determine water-soluble forms of same carboxylic acids — (oxalic and formic acids) in soils by ion chromatography with gradient elution. For the separation and determination of water-soluble carboxylic acids we used reagent-free gradient elution ion-exchange chromatography ICS-2000 (Dionex, USA), the model solutions of oxalate and formate ions, and leachates from soils of the Kola Peninsula. The optimal gradient program was established for separation and detection of oxalate and formate ions in water solutions by ion chromatography. A stability indicating method was developed for the simultaneous determination of water-soluble organic acids in soils. The method has shown high detection limits such as 0.03 mg/L for oxalate ion and 0.02 mg/L for formate ion. High signal reproducibility was achieved in wide range of intensities which correspond to the following ion concentrations: from 0.04 mg/g to 10 mg/L (formate), from 0.1 mg/g to 25 mg/L (oxalate). The concentration of formate and oxalate ions in soil samples is from 0.04 to 0.9 mg/L and 0.45 to 17 mg/L respectively.

  4. Core-shell Fe3O4 polydopamine nanoparticles as sorbent for magnetic dispersive solid-phase extraction of copper from food samples.

    PubMed

    Yavuz, Emre; Tokalıoğlu, Şerife; Patat, Şaban

    2018-10-15

    In the present study, core-shell Fe 3 O 4 polydopamine nanoparticles were synthesized and used for the first time as an adsorbent for the vortex assisted magnetic dispersive solid phase extraction of copper from food samples. After elution, copper in the solutions was determined by FAAS. The adsorbent was characterized using X-ray diffraction, scanning electron microscopy, energy dispersive X-ray spectroscopy, Fourier transform infrared spectroscopy, Brunauer-Emmett-Teller surface area, and zeta potential measurements. Various parameters affecting the magnetic dispersive solid-phase extraction were evaluated. The optimum pH and magnetic adsorbent amount were found to be 5 and 40 mg, respectively. Elution was made by 3 mL of 2 mol L -1 HNO 3 .The major advantage of the method is the fast equilibration during adsorption without the need for vortexing or shaking. The preconcentration factor and detection limit of the method were found to be 150 and 0.22 mg L -1 , respectively. The precision (as RSD%) and adsorption capacity of the method were 3.7% and 28 mg g -1 , respectively. The method was successfully verified by analyzing four certified reference materials (SPS-WW1 Batch 114 Wastewater, TMDA-53.3 Lake water, BCR-482 Lichen and 1573a Tomato Leaves) and by addition/recovery tests of copper standard solution in organic baby food, muesli, macaroni, honey, and milk samples. Copyright © 2018 Elsevier Ltd. All rights reserved.

  5. Analysis of underivatised low volatility compounds by comprehensive two-dimensional gas chromatography with a short primary column.

    PubMed

    Novaes, Fábio Junior Moreira; Kulsing, Chadin; Bizzo, Humberto Ribeiro; de Aquino Neto, Francisco Radler; Rezende, Claudia Moraes; Marriott, Philip John

    2018-02-09

    Comprehensive two-dimensional gas chromatography (GC×GC) approaches with cryogenic modulation were developed for the qualitative analysis of selected low volatility compounds in raw coffee bean extracts, without derivatisation. The approaches employed short first ( 1 D) and second ( 2 D) dimension columns, specifically a 1 D 65% phenyl methyl siloxane column (11m) and a 2 D 5% phenyl methyl siloxane column (1m), which allowed elution of high molar mass compounds (e.g.>600Da). Solutes included hydrocarbons, fatty acids, diterpenes, tocopherols, sterols, diterpene esters, and di- and triacylglycerides. An oven temperature program up to 370°C was employed. The effects of experimental conditions were investigated, revealing that the GC×GC results strongly depended on the cryogenic trap T, and oven T program. An appropriate condition was selected and further applied for group type analysis of low volatility compounds in green Arabica coffee beans. Retention indices were compiled for 1D GC analysis and were similar for the composite column data in GC×GC. The elution of some compounds was confirmed by use of authentic standards. The approach allowed direct analysis of coffee extract in ethyl acetate solution, with improved analyte peak capacity (approximately 200 compounds were detected) without prior fractionation or pre-treatment of the sample. This avoided potential hydrolysis of high molar mass conjugate esters as well as degradation of thermally labile compounds such as the derivatives of the diterpenes cafestol and kahweol. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Pore networks and polymer rearrangement on a drug-eluting stent as revealed by correlated confocal Raman and atomic force microscopy.

    PubMed

    Biggs, Kevin B; Balss, Karin M; Maryanoff, Cynthia A

    2012-05-29

    Drug release from and coating morphology on a CYPHER sirolimus-eluting coronary stent (SES) during in vitro elution were studied by correlated confocal Raman and atomic force microscopy (CRM and AFM, respectively). Chemical surface and subsurface maps of the SES were generated in the same region of interest by CRM and were correlated with surface topography measured by AFM at different elution times. For the first time, a direct correlation between drug-rich regions and the coating morphology was made on a drug-eluting medical device, linking drug release with pore formation, pore throats, and pore networks. Drug release was studied on a drug-eluting stent (DES) system with a multicomponent carrier matrix (poly(n-butyl methacrylate) [PBMA] and poly(ethylene-co-vinyl acetate) [PEVA]). The polymer was found to rearrange postelution because confluence of the carrier polymer matrix reconstituted the voids created by drug release.

  7. Effect of leaching residual methyl methacrylate concentrations on in vitro cytotoxicity of heat polymerized denture base acrylic resin processed with different polymerization cycles

    PubMed Central

    BURAL, Canan; AKTAŞ, Esin; DENIZ, Günnur; ÜNLÜÇERÇI, Yeşim; BAYRAKTAR, Gülsen

    2011-01-01

    Objectives Residual methyl methacrylate (MMA) may leach from the acrylic resin denture bases and have adverse effects on the oral mucosa. This in vitro study evaluated and correlated the effect of the leaching residual MMA concentrations ([MMA]r) on in vitro cytotoxicity of L-929 fibroblasts. Material and Methods A total of 144 heat-polymerized acrylic resin specimens were fabricated using 4 different polymerization cycles: (1) at 74ºC for 9 h, (2) at 74ºC for 9 h and terminal boiling (at 100ºC) for 30 min, (3) at 74ºC for 9 h and terminal boiling for 3 h, (4) at 74ºC for 30 min and terminal boiling for 30 min. Specimens were eluted in a complete cell culture medium at 37ºC for 1, 2, 5 and 7 days. [MMA]r in eluates was measured using high-performance liquid chromatography. In vitro cytotoxicity of eluates on L-929 fibroblasts was evaluated by means of cell proliferation using a tetrazolium salt XTT (sodium 3´-[1-phenyl-aminocarbonyl)-3,4-tetrazolium]bis(4-methoxy-6-nitro)benzenesulphonic acid) assay. Differences in [MMA]r of eluates and cell proliferation values between polymerization cycles were statistically analyzed by Kruskal-Wallis, Friedman and Dunn's multiple comparison tests. The correlation between [MMA]r of eluates and cell proliferation was analyzed by Pearson's correlation test (p<0.05). Results [MMA]r was significantly (p≤0.001) higher in eluates of specimens polymerized with cycle without terminal boiling after elution of 1 and 2 days. Cell proliferation values for all cycles were significantly (p<0.01) lower in eluates of 1 day than those of 2 days. The correlation between [MMA]r and cell proliferation values was negative after all elution periods, showing significance (p<0.05) for elution of 1 and 2 days. MMA continued to leach from acrylic resin throughout 7 days and leaching concentrations markedly reduced after elution of 1 and 2 days. Conclusion Due to reduction of leaching residual MMA concentrations, use of terminal boiling in the polymerization process for at least 30 min and water storage of the heat-polymerized denture bases for at least 1 to 2 days before denture delivery is clinically recommended for minimizing the residual MMA and possible cytotoxic effects. PMID:21956586

  8. Separation and purification of both tea seed polysaccharide and saponin from camellia cake extract using macroporous resin.

    PubMed

    Yang, Pengjie; Zhou, Mingda; Zhou, Chengyun; Wang, Qian; Zhang, Fangfang; Chen, Jian

    2015-02-01

    A novel method to separate and purify tea seed polysaccharide and tea seed saponin from camellia cake extract by macroporous resin was developed. Among four kinds of resins (AB-8, NKA-9, XDA-6, and D4020) tested, AB-8 macroporous resin possessed optimal separating capacity for the two substances and thus was selected for the separation, in which deionized water was used to elute tea seed polysaccharide, 0.25% NaOH solution to remove the undesired pigments, and 90% ethanol to elute tea seed saponin. Further dynamic adsorption/desorption experiments on AB-8 resin-based column chromatography were conducted to obtain the optimal parameters. Under optimal dynamic adsorption and desorption conditions, 18.7 and 11.8% yield of tea seed polysaccharide and tea seed saponin were obtained with purities of 89.2 and 96.0%, respectively. The developed method provides a potential approach for the large-scale production of tea seed polysaccharide and tea seed saponin from camellia cake. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Micro-scale flow system for on-line multielement preconcentration from saliva digests and determination by inductively coupled plasma optical emission spectrometry

    NASA Astrophysics Data System (ADS)

    Menegário, Amauri A.; Fernanda Giné, Maria

    2001-10-01

    A micro-scale flow system is proposed for on-line preconcentration of Cd, Cu, Mn, Ni and Pb in saliva samples and their determination by inductively coupled plasma optical emission spectrometry (ICP-OES). A small column containing 8 μl of AG50W-X8 resin was inserted into the flow system, assembled with capillary tubes and connected to a micro-concentric nebulizer. The elution of the analytes was performed with 3 mol l -1 HCl at a flow rate of 82 μl min -1. The ICP-OES signal acquisition program permits measurements for 5 s in the concentrated portion of the transient elution peaks. A sample volume of 1 ml was required to obtain enrichment factors of 46, 23, 17, 18 and 44 for Cd, Cu, Mn, Ni and Pb, respectively. The relative standard deviations for a 50-μg l -1 multi-analyte solution were ≤6.5%. The recoveries for Cd, Cu, Mn, Ni and Pb in digested human saliva samples were between 86 and 111%. The sample throughput was 24 h -1.

  10. Quantitative spatial distribution of sirolimus and polymers in drug-eluting stents using confocal Raman microscopy.

    PubMed

    Balss, K M; Llanos, G; Papandreou, G; Maryanoff, C A

    2008-04-01

    Raman spectroscopy was used to differentiate each component found in the CYPHER Sirolimus-eluting Coronary Stent. The unique spectral features identified for each component were then used to develop three separate calibration curves to describe the solid phase distribution found on drug-polymer coated stents. The calibration curves were obtained by analyzing confocal Raman spectral depth profiles from a set of 16 unique formulations of drug-polymer coatings sprayed onto stents and planar substrates. The sirolimus model was linear from 0 to 100 wt % of drug. The individual polymer calibration curves for poly(ethylene-co-vinyl acetate) [PEVA] and poly(n-butyl methacrylate) [PBMA] were also linear from 0 to 100 wt %. The calibration curves were tested on three independent drug-polymer coated stents. The sirolimus calibration predicted the drug content within 1 wt % of the laboratory assay value. The polymer calibrations predicted the content within 7 wt % of the formulation solution content. Attenuated total reflectance Fourier transform infrared (ATR-FTIR) spectra from five formulations confirmed a linear response to changes in sirolimus and polymer content. Copyright 2007 Wiley Periodicals, Inc.

  11. Development of bisphenol A-removing recombinant Escherichia coli by monomeric and dimeric surface display of bisphenol A-binding peptide.

    PubMed

    Maruthamuthu, Murali Kannan; Hong, Jiyeon; Arulsamy, Kulandaisamy; Somasundaram, Sivachandiran; Hong, SoonHo; Choe, Woo-Seok; Yoo, Ik-Keun

    2018-04-01

    Peptide-displaying Escherichia coli cells were investigated for use in adsorptive removal of bisphenol A (BPA) both in Luria-Bertani medium including BPA or ATM thermal paper eluted wastewater. Two recombinant strains were constructed with monomeric and dimeric repeats of the 7-mer BPA-binding peptide (KSLENSY), respectively. Greater than threefold increased adsorption of BPA [230.4 µmol BPA per g dry cell weight (DCW)] was found in dimeric peptide-displaying cells compared to monomeric strains (63.4 µmol per g DCW) in 15 ppm BPA solution. The selective removal of BPA from a mixture of BPA analogs (bisphenol F and bisphenol S) was verified in both monomeric and dimeric peptide-displaying cells. The binding chemistry of BPA with the peptide was assumed, based on molecular docking analysis, to be the interaction of BPA with serine and asparagine residues within the 7-mer peptide sequence. The peptide-displaying cells also functioned efficiently in thermal paper eluted wastewater containing 14.5 ppm BPA.

  12. [Separation of catechins and caffeine in tea polyphenol by isocratic elution high performance liquid chromatography].

    PubMed

    Tang, G Y; Wu, H J; Wu, L; Li, Z J; Yao, Y G

    2001-05-01

    The catechins, particularly in green tea, have been found to possess anti-mutagenic and anti-tumorigenic properties. As each catechin possesses distinct properties, a simple and rapid method that could be used for analysis of individual catechins in a complex mixture would be necessary. A relatively simple and rapid method for simultaneous separation of five catechins and caffeine in tea polyphenol by isocratic elution high performance liquid chromatography has been developed. The analysis could be finished within 30 min. They were measured using Resolve C18 column (at 43 degrees C) and UV detector (at 280 nm), water-85% phosphoric acid aqueous solution-acetonitrile-dimethyl formamide(DMF) (859:1:120:20, V/V) as mobile phase. There was a good linear relationship between the content of component and its peak area for catechins and caffeine, with the correlation coefficients of 0.9992-0.9999. The average recoveries (n = 5) were 83.33%-104.42%, and the relative standard deviations (n = 6) were 0.74%-1.43%. The effect of concentration of DMF in mobile phase was studied.

  13. Development of an elution device for ViroCap virus filters.

    PubMed

    Fagnant, Christine Susan; Toles, Matthew; Zhou, Nicolette Angela; Powell, Jacob; Adolphsen, John; Guan, Yifei; Ockerman, Byron; Shirai, Jeffry Hiroshi; Boyle, David S; Novosselov, Igor; Meschke, John Scott

    2017-10-19

    Environmental surveillance of waterborne pathogens is vital for monitoring the spread of diseases, and electropositive filters are frequently used for sampling wastewater and wastewater-impacted surface water. Viruses adsorbed to electropositive filters require elution prior to detection or quantification. Elution is typically facilitated by a peristaltic pump, although this requires a significant startup cost and does not include biosafety or cross-contamination considerations. These factors may pose a barrier for low-resource laboratories that aim to conduct environmental surveillance of viruses. The objective of this study was to develop a biologically enclosed, manually powered, low-cost device for effectively eluting from electropositive ViroCap™ virus filters. The elution device described here utilizes a non-electric bilge pump, instead of an electric peristaltic pump or a positive pressure vessel. The elution device also fully encloses liquids and aerosols that could contain biological organisms, thereby increasing biosafety. Moreover, all elution device components that are used in the biosafety cabinet are autoclavable, reducing cross-contamination potential. This device reduces costs of materials while maintaining convenience in terms of size and weight. With this new device, there is little sample volume loss due to device inefficiency, similar virus yields were demonstrated during seeded studies with poliovirus type 1, and the time to elute filters is similar to that required with the peristaltic pump. The efforts described here resulted in a novel, low-cost, manually powered elution device that can facilitate environmental surveillance of pathogens through effective virus recovery from ViroCap filters while maintaining the potential for adaptability to other cartridge filters.

  14. Biosolid colloid-mediated transport of copper, zinc, and lead in waste-amended soils.

    PubMed

    Karathanasis, A D; Johnson, D M C; Matocha, C J

    2005-01-01

    Increasing land applications of biosolid wastes as soil amendments have raised concerns about potential toxic effects of associated metals on the environment. This study investigated the ability of biosolid colloids to transport metals associated with organic waste amendments through subsurface soil environments with leaching experiments involving undisturbed soil monoliths. Biosolid colloids were fractionated from a lime-stabilized, an aerobically digested, and a poultry manure organic waste and applied onto the monoliths at a rate of 0.7 cm/h. Eluents were monitored for Cu, Zn, Pb, and colloid concentrations over 16 to 24 pore volumes of leaching. Mass-balance calculations indicated significantly higher (up to 77 times) metal elutions in association with the biosolid colloids in both total and soluble fractions over the control treatments. Eluted metal loads varied with metal, colloid, and soil type, following the sequences Zn = Cu > Pb, and ADB > PMB > LSB colloids. Colloid and metal elution was enhanced by decreasing pH and colloid size, and increasing soil macroporosity and organic matter content. Breakthrough curves were mostly irregular, showing several maxima and minima as a result of preferential macropore flow and multiple clogging and flushing cycles. Soil- and colloid-metal sorption affinities were not reliable predictors of metal attenuation/elution loads, underscoring the dynamic nature of transport processes. The findings demonstrate the important role of biosolid colloids as contaminant carriers and the significant risk they pose, if unaccounted, for soil and ground water contamination in areas receiving heavy applications of biosolid waste amendments.

  15. Reversed-Phase High-Performance Liquid Chromatography for the Quantification and Optimization for Extracting 10 Kinds of Carotenoids in Pepper (Capsicum annuum L.) Leaves.

    PubMed

    Li, Jing; Xie, Jianming; Yu, Jihua; Lv, Jian; Zhang, Junfeng; Wang, Xiaolong; Wang, Cheng; Tang, Chaonan; Zhang, Yingchun; Dawuda, Mohammed Mujitaba; Zhu, Daiqiang; Ma, Guoli

    2017-09-27

    Carotenoids are considered to be crucial elements in many fields and, furthermore, the significant factor in pepper leaves under low light and chilling temperature. However, little literature focused on the method to determinate and extract the contents of carotenoid compositions in pepper leaves. Therefore, a time-saving and highly sensitive reversed-phase high-performance liquid chromatography method for separation and quantification of 10 carotenoids was developed, and an optimized technological process for carotenoid composition extraction in pepper leaves was established for the first time. Our final method concluded that six xanthophylls eluted after about 9-26 min. In contrast, four carotenes showed higher retention times after nearly 28-40 min, which significantly shortened time and improved efficiency. Meanwhile, we suggested that 8 mL of 20% KOH-methanol solution should be added to perform saponification at 60 °C for 30 min. The ratio of solid-liquid was 1:8, and the ultrasound-assisted extraction time was 40 min.

  16. Affinity monolith-integrated poly(methyl methacrylate) microchips for on-line protein extraction and capillary electrophoresis.

    PubMed

    Sun, Xiuhua; Yang, Weichun; Pan, Tao; Woolley, Adam T

    2008-07-01

    Immunoaffinity monolith pretreatment columns have been coupled with capillary electrophoresis separation in poly(methyl methacrylate) (PMMA) microchips. Microdevices were designed with eight reservoirs to enable the electrically controlled transport of selected analytes and solutions to carry out integrated immunoaffinity extraction and electrophoretic separation. The PMMA microdevices were fabricated reproducibly and with high fidelity by solvent imprinting and thermal bonding methods. Monoliths with epoxy groups for antibody immobilization were prepared by direct in situ photopolymerization of glycidyl methacrylate and ethylene glycol dimethacrylate in a porogenic solvent consisting of 70% 1-dodecanol and 30% cyclohexanol. Antifluorescein isothiocyanate was utilized as a model affinity group in the monoliths, and the immobilization process was optimized. A mean elution efficiency of 92% was achieved for the monolith-based extraction of fluorescein isothiocyanate (FITC)-tagged human serum albumin. FITC-tagged proteins were purified from a contaminant protein and then separated electrophoretically using these devices. The developed immunoaffinity column/capillary electrophoresis microdevices show great promise for combining sample pretreatment and separation in biomolecular analysis.

  17. Affinity Monolith-Integrated Poly(methyl Methacrylate) Microchips for On-Line Protein Extraction and Capillary Electrophoresis

    PubMed Central

    Sun, Xiuhua; Yang, Weichun; Pan, Tao; Woolley, Adam T.

    2008-01-01

    Immunoaffinity monolith pretreatment columns have been coupled with capillary electrophoresis separation in poly(methyl methacrylate) (PMMA) microchips. Microdevices were designed with 8 reservoirs to enable the electrically controlled transport of selected analytes and solutions to carry out integrated immunoaffinity extraction and electrophoretic separation. The PMMA microdevices were fabricated reproducibly and with high fidelity by solvent imprinting and thermal bonding methods. Monoliths with epoxy groups for antibody immobilization were prepared by direct in-situ photopolymerization of glycidyl methacrylate and ethylene dimethacrylate in a porogenic solvent consisting of 70% dodecanol and 30% hexanol. Anti-fluorescein isothiocyanate (FITC) was utilized as a model affinity group in the monoliths, and the immobilization process was optimized. A mean elution efficiency of 92% was achieved for the monolith-based extraction of FITC-tagged human serum albumin. FITC-tagged proteins were purified from a contaminant protein and then separated electrophoretically using these devices. The developed immunoaffinity column/capillary electrophoresis microdevices show great promise for combining sample pretreatment and separation in biomolecular analysis. PMID:18479142

  18. WE-G-BRE-08: Radiosensitization by Olaparib Eluting Nanospheres

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tangutoori, S; Kumar, R; Sridhar, S

    2014-06-15

    Purpose: Permanent prostate brachytherapy often uses inert bio-absorbable spacers to achieve the desired geometric distribution of sources within the prostate. Transforming these spacers into implantable nanoplatforms for chemo-radiation therapy (INCeRT) provides a means of providing sustained in-situ release of radiosensitizers in the prostate to enhance the therapeutic ratio of the procedure. Olaparib, a PARP inhibitor, suppresses DNA repair processes present during low dose rate continuous irradiation. This work investigates the radiosensitizing/DNA damage repair inhibition by NanoOlaparib eluting nanospheres. Methods: Human cell line PC3 (from ATCC), was maintained in F12-k medium supplemented with fetal bovine serum. Clonogenic assay kit (from Fischermore » Scientific) was used to fix and stain the cells to determine the long term effects of irradiation. Nanoparticle size and zeta potential of nanospheres were determined using a Zeta particle size analyzer. The incorporation of Olaparib in nanospheres was evaluated by HPLC. Irradiation was performed in a small animal irradiator operating at 220 KeV.The long term effects of radio-sensitization with olaparib and nanoolaparib was determined using the clonogenic assay at 2 Gy and 4 Gy doses. The cells were allowed to grow for around 10 doubling cycles, The colonies were fixed and stained using clonogenic assay kit. The excess stain was washed off using DI water and the images were taken using a digital camera. Results: Radiosensitization studies were carried out in prostate cancer cell line, PC3 radiation at 0, 2 and 4Gy doses. Strongest dose response was observed with nanoolaparib treated cells compared to untreated cells. Conclusion: A two stage drug release of drug eluting nanospheres from a biodegradable spacer has been suggested for sustained in-situ release of Olaparib to suppress DNA repair processes during prostate brachytherapy. The Olaparib eluting nanospheres had the same in-vitro radiosensitizing effect as free olaparib. DOD 1R21CA16977501, A. David Mazzone Awards Program 2012PD164.« less

  19. Immobilization of sodium alginate sulfates on polysulfone ultrafiltration membranes for selective adsorption of low-density lipoprotein.

    PubMed

    Wang, Wei; Huang, Xiao-Jun; Cao, Jian-Da; Lan, Ping; Wu, Wen

    2014-01-01

    A novel method for the immobilization of sodium alginate sulfates (SAS) on polysulfone (PSu) ultrafiltration membranes to achieve selective adsorption of low-density lipoprotein (LDL) was developed, which involved the photoinduced graft polymerization of acrylamide on the membrane and the Hofmann rearrangement reaction of grafted acrylamide followed by chemical binding of SAS with glutaraldehyde. The surface modification processes were confirmed by attenuated total reflectance Fourier transform infrared spectroscopy and X-ray photoelectron spectroscopy characterization. Zeta potential and water contact angle measurements were performed to investigate the surface charge and wettability of the membranes. An enzyme-linked immunosorbent assay was used to measure the binding of LDL on plain and modified PSu membranes. It was found that the PSu membrane immobilized with sodium alginate sulfates (PSu-SAS) greatly enhanced the selective adsorption of LDL from protein solutions and the absorbed LDL could be easily eluted with sodium chloride solution, indicating a specific and reversible binding of LDL to SAS, mainly driven by electrostatic forces. Furthermore, the PSu-SAS membrane showed good blood compatibility as examined by platelet adhesion. The results suggest that the PSu-SAS membranes are promising for application in simultaneous hemodialysis and LDL apheresis therapy. Copyright © 2013 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  20. 3-Year Clinical Follow-Up of the RIBS IV Clinical Trial: A Prospective Randomized Study of Drug-Eluting Balloons Versus Everolimus-Eluting Stents in Patients With In-Stent Restenosis in Coronary Arteries Previously Treated With Drug-Eluting Stents.

    PubMed

    Alfonso, Fernando; Pérez-Vizcayno, María José; Cuesta, Javier; García Del Blanco, Bruno; García-Touchard, Arturo; López-Mínguez, José Ramón; Masotti, Mónica; Zueco, Javier; Cequier, Angel; Velázquez, Maite; Moreno, Raúl; Mainar, Vicente; Domínguez, Antonio; Moris, Cesar; Molina, Eduardo; Rivero, Fernando; Jiménez-Quevedo, Pilar; Gonzalo, Nieves; Fernández-Pérez, Cristina

    2018-05-28

    This study sought to compare the long-term safety and efficacy of drug-eluting balloons (DEB) and everolimus-eluting stents (EES) in patients with in-stent restenosis (ISR) of drug-eluting stents (DES). Treatment of patients with DES-ISR remains a challenge. The RIBS IV (Restenosis Intra-Stent of Drug-Eluting Stents: Drug-Eluting Balloons vs Everolimus-Eluting Stents) trial is a prospective multicenter randomized clinical trial comparing DEB and EES in patients with DES-ISR. The pre-specified comparison of the 3-year clinical outcomes obtained with these interventions is the main objective of the present study. A total of 309 patients with DES-ISR were randomized to DEB (n = 154) or EES (n = 155). At angiographic follow-up, the in-segment minimal lumen diameter was larger in the EES arm (2.03 ± 0.7 mm vs. 1.80 ± 0.6 mm; p < 0.01). Three-year clinical follow-up was obtained in all enrolled patients (100%). The combined clinical outcome measure of cardiac death, myocardial infarction and target lesion revascularization was significantly reduced in the EES arm (19 [12.3%] vs. 31 [20.1%]; p = 0.04; hazard ratio: 0.57 [95% confidence interval: 0.34 to 0.96]), driven by a lower need for target lesion revascularization (11 [7.1%] vs. 24 [15.6%]; p = 0.015; hazard ratio: 0.43 [95% confidence interval: 0.21 to 0.87]). The need for "late" (>1 year) target lesion revascularization (2.6% vs. 4%) and target vessel revascularization (4% vs. 6.6%) was similar in the 2 arms. Rates of cardiac death (3.9% vs. 3.2%), myocardial infarction (2.6% vs. 4.5%), and stent thrombosis (1.3% vs. 2.6%) at 3 years were also similar in both arms. The 3-year clinical follow-up of this randomized clinical trial demonstrates that in patients with DES-ISR, EES reduce the need for repeat interventions compared with DEB. (Restenosis Intra-Stent of Drug-Eluting Stents: Drug-Eluting Balloons vs Everolimus-Eluting Stents [RIBS IV]; NCT01239940). Published by Elsevier Inc.

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Yaping; Williams, Brent J.; Goldstein, Allen H.

    Here, we present a rapid method for apportioning the sources of atmospheric organic aerosol composition measured by gas chromatography–mass spectrometry methods. Here, we specifically apply this new analysis method to data acquired on a thermal desorption aerosol gas chromatograph (TAG) system. Gas chromatograms are divided by retention time into evenly spaced bins, within which the mass spectra are summed. A previous chromatogram binning method was introduced for the purpose of chromatogram structure deconvolution (e.g., major compound classes) (Zhang et al., 2014). Here we extend the method development for the specific purpose of determining aerosol samples' sources. Chromatogram bins are arrangedmore » into an input data matrix for positive matrix factorization (PMF), where the sample number is the row dimension and the mass-spectra-resolved eluting time intervals (bins) are the column dimension. Then two-dimensional PMF can effectively do three-dimensional factorization on the three-dimensional TAG mass spectra data. The retention time shift of the chromatogram is corrected by applying the median values of the different peaks' shifts. Bin width affects chemical resolution but does not affect PMF retrieval of the sources' time variations for low-factor solutions. A bin width smaller than the maximum retention shift among all samples requires retention time shift correction. A six-factor PMF comparison among aerosol mass spectrometry (AMS), TAG binning, and conventional TAG compound integration methods shows that the TAG binning method performs similarly to the integration method. However, the new binning method incorporates the entirety of the data set and requires significantly less pre-processing of the data than conventional single compound identification and integration. In addition, while a fraction of the most oxygenated aerosol does not elute through an underivatized TAG analysis, the TAG binning method does have the ability to achieve molecular level resolution on other bulk aerosol components commonly observed by the AMS.« less

  2. Post-elution concentration of (188)Re by an electrochemical method.

    PubMed

    Chakravarty, Rubel; Dash, Ashutosh; Pillai, M R A; Venkatesh, Meera

    2010-12-01

    High specific activity (188)Re required for nuclear medicine is mostly obtained from (188)W/(188)Re generators. As the parent radionuclide (188)W is of low specific activity (<185 GBq/g), a relatively large volume of 0.9% saline is required for the elution of (188)Re. Post-elution concentration is needed in order to increase the radioactive concentration of the eluted (188)Re. An electrochemical procedure to concentrate (188)Re suitable for the preparation of radiopharmaceuticals is developed. (188)Re eluted from an alumina generator could be concentrated approximately 100 fold, and it could be used to label DMSA and HEDP with >98% yield. Copyright 2010 Elsevier Ltd. All rights reserved.

  3. Econazole-releasing porous space maintainers for fungal periprosthetic joint infection.

    PubMed

    Tatara, Alexander M; Rozich, Allison J; Kontoyiannis, Panayiotis D; Watson, Emma; Albert, Nathaniel D; Bennett, George N; Mikos, Antonios G

    2018-05-11

    While antibiotic-eluting polymethylmethacrylate space maintainers have shown efficacy in the treatment of bacterial periprosthetic joint infection and osteomyelitis, antifungal-eluting space maintainers are associated with greater limitations for treatment of fungal musculoskeletal infections including limited elution concentration and duration. In this study, we have designed a porous econazole-eluting space maintainer capable of greater inhibition of fungal growth than traditional solid space maintainers. The eluted econazole demonstrated bioactivity in a concentration-dependent manner against the most common species responsible for fungal periprosthetic joint infection as well as staphylococci. Lastly, these porous space maintainers retain compressive mechanical properties appropriate to maintain space before definitive repair of the joint or bony defect.

  4. [Optimized isolation and purification of non-typeable Haemophilus influenzae Haps protein].

    PubMed

    Li, Wan-yi; Kuang, Yu; Li, Ming-yuan; Yang, Yuan; Jiang, Zhong-hua; Yao, Feng; Chen, Chang-chun

    2007-12-01

    To optimize the isolation and purification conditions for Hap(s) protein of non-typeable Haemophilus influenzae. Hap(s) protein was purified by ammonium sulfate precipitation, dialysis desalting and Hitrap weak cation exchange columns of CM Sepharose Fast Flow. The condition of the elution was optimized for pH and ionic strength, the absorbance at 280 nm of the elution samples were detected, and the targeted protein band in the collected samples was observed by SDS-PAGE electrophoresis. The Hitrap ion exchange column was eluted with buffer 1, which resulted in a baseline distribution of absorbance at 280 nm. Buffer 2 elution of the column resulted in the presence of peak absorbance with trails, which was identified to be constituted by some low molecular weight bands by subsequent SDS-PAGE. In serial column elution with buffer 3 with different ionic strength, a peak absorbance was observed with the ionic strength of 100 mmol/L NaCl, and SDS-PAGE confirmed that the peak was generated by the target protein. No obvious peaks or bands in SDS-PAGE occurred with the other ionic strengths. The pH of the buffer only affect the elution of the irrelevant proteins rather than the Hap(s) protein, and elution with the buffer containing 100 mmol/L NaCl can be optimal for eluting the Hap(s) protein.

  5. [Optimization of Cryptosporidium and Giardia detection in water environment using automatic elution station Filta-Max xpress].

    PubMed

    Matuszewska, Renata; Szczotko, Maciej; Krogulska, Bozena

    2012-01-01

    The presence of parasitic protozoa in drinking water is mostly a result of improperly maintened the water treatment process. Currently, in Poland the testing of Cryptosporidium and Giardia in water as a part of routine monitoring of water is not perform. The aim of this study was the optimization of the method of Cryptosporidium and Giardia detection in water according to the main principles of standard ISO 15553:2006 and using Filta-Max xpress automatic elution station. Preliminary tests were performed on the samples contaminated with oocysts and cysts of reference strains of both parasitic protozoa. Further studies were carried out on environmental samples of surface water sampled directly from the intakes of water (21 samples from Vistula River and 8 samples from Zegrzynski Lake). Filtration process and samples volume reducing were performed using an automatic elution system Filta-Max xpress. Next, samples were purified during immunomagnetic separation process (IMS). Isolated cysts and oocysts were stained with FITC and DAPI and than the microscopic observation using an epifluorescence microscope was carried out. Recovery of parasite protozoa in all contaminated water samples after 9-cycles elution process applied was mean 60.6% for Cryptosporidium oocysts and 36.1% for Giardia cysts. Studies on the environmental surface water samples showed the presence of both parasitic protozoa. Number of detected Giardia cysts ranged from 1.0/10 L up to 4.5/10 L in samples from Zegrzynski Lake and from 1.0/10 L up to 38.9/10 L in samples from Vistula River. Cryptosporidium oocysts were present in 50% of samples from the Zegrzynski Lake and in 47.6% of samples from the Vistula River, and their number in both cases was similar and ranged from 0.5 up to 2.5 oocyst/10 L. The results show that applied procedure is appropriate for detection the presence of parasitic protosoan in water, but when water contains much amount of inorganic matter and suspended solids test method have to be modified like subsamples preparation and filtration process speed reduction. The applied method with the modification using Filta-Max xpress system can be useful for the routine monitoring of water. Detection of Cryptosporidium and Giardia in all samples of water taken from the intakes of surface water shows the possibility oftransfering of the protozoan cysts into the water intended for the consumption, therefore the testing of Cryptosporidium and Giardia should be included into the monitoring of water.

  6. Enhancing concentration and mass sensitivities for liquid chromatography trace analysis of clopyralid in drinking water.

    PubMed

    Gu, Binghe; Meldrum, Brian; McCabe, Terry; Phillips, Scott

    2012-01-01

    A theoretical treatment was developed and validated that relates analyte concentration and mass sensitivities to injection volume, retention factor, particle diameter, column length, column inner diameter and detection wavelength in liquid chromatography, and sample volume and extracted volume in solid-phase extraction (SPE). The principles were applied to improve sensitivity for trace analysis of clopyralid in drinking water. It was demonstrated that a concentration limit of detection of 0.02 ppb (μg/L) for clopyralid could be achieved with the use of simple UV detection and 100 mL of a spiked drinking water sample. This enabled reliable quantitation of clopyralid at the targeted 0.1 ppb level. Using a buffered solution as the elution solvent (potassium acetate buffer, pH 4.5, containing 10% of methanol) in the SPE procedures was found superior to using 100% methanol, as it provided better extraction recovery (70-90%) and precision (5% for a concentration at 0.1 ppb level). In addition, the eluted sample was in a weaker solvent than the mobile phase, permitting the direct injection of the extracted sample, which enabled a faster cycle time of the overall analysis. Excluding the preparation of calibration standards, the analysis of a single sample, including acidification, extraction, elution and LC run, could be completed in 1 h. The method was used successfully for the determination of clopyralid in over 200 clopyralid monoethanolamine-fortified drinking water samples, which were treated with various water treatment resins. Copyright © 2012 WILEY‐VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Efficacy of a Dexamethasone-Eluting Nitinol Stent on the Inhibition of Pseudointimal Hyperplasia in a Transjugular Intrahepatic Portosystemic Shunt: An Experimental Study in a Swine Model

    PubMed Central

    Seo, Tae-Seok; Park, Young-Koo; Song, Ho-Young; Park, Sang Joon; Yuk, Sun-Hong

    2005-01-01

    Objective We wanted to evaluate the feasibility and efficacy of using a dexamethasone (DM)-eluting nitinol stent to inhibit the pseudointimal hyperplasia following stent placement in the transjugular intrahepatic portosystemic shunt tract (TIPS) of a swine. Materials and Methods Fifteen stents were constructed using 0.15 mm-thick nitinol wire; they were 60 mm in length and 10 mm in diameter. The metallic stents were then classified into three types; type 1 and 2 was coated with the mixture of 12% and 20%, respectively, of DM solution and polyurethane (PU), while type 3 was a bare stent that was used for control study. In fifteen swine, each type of stent was implanted in the TIPS tract of 5 swine, and each animal was sacrificed 2 weeks after TIPS creation. The proliferation of the pseudointima was evaluated both on follow-up portogram and pathologic examination. Results One TIPS case, using the type 1 stent, and two TIPS cases, using the type 2 stent, maintained their luminal patency while the others were all occluded. On the histopathologic analysis, the mean of the maximum pseudointimal hyperplasia was expressed as the percentage of the stent radius that was patent, and these values were 51.2%, 50% and 76% for the type 1, 2, and 3 stents, respectively. Conclusion The DM-eluting stent showed a tendency to reduce the development of pseudointimal hyperplasia in the TIPS tract of a swine model with induced-portal hypertension. PMID:16374082

  8. Application of NaClO-treated multiwalled carbon nanotubes as solid phase extraction sorbents for preconcentration of trace 2,4-dichlorophenoxyacetic acid in aqueous samples.

    PubMed

    Lu, Ping; Deng, Dayi; Ni, Xiaodan

    2012-09-01

    Multiwalled carbon nanotubes functionalized by oxidation of original multiwalled carbon nanotubes with NaClO were prepared and their application as solid phase extraction sorbent for 2,4-dichlorophenoxyacetic acid (2,4-D) was investigated systemically, and a new method was developed for the determination of trace 2,4-D in water samples based on extraction and preconcentration of 2,4-D with solid phase extraction columns packed with NaClO-treated multiwalled carbon nanotubes prior to its determination by HPLC. The optimum experimental parameters for preconcentration of 2,4-D, including the column activating conditions, the amount of the sorbent, pH of the sample, elution composition, and elution volume, were investigated. The results indicated 2,4-D could be quantitatively retained by 100 mg NaClO-treated multiwalled carbon nanotubes at pH 5, and then eluted completely with 10 mL 3:1 (v/v) methanol-ammonium acetate solution (0.3 mol/L). The detection limit of this method for 2,4-D was 0.15 μg/L, and the relative standard deviation was 2.3% for fortified tap water samples and 2.5% for fortified riverine water sample at the 10 μg/L level. The method was validated using fortified tap water and riverine water samples with known amount of 2,4-D at the 0.4, 10, and 30 μg/L levels, respectively. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Design and scaleup of downstream processing of monoclonal antibodies for cancer therapy: from research to clinical proof of principle.

    PubMed

    Horenstein, Alberto L; Crivellin, Federico; Funaro, Ada; Said, Marcela; Malavasi, Fabio

    2003-04-01

    Murine monoclonal antibodies (mAb) from cell culture supernatants have been purified in order to acquire clinical grade for in vivo cancer treatment. The starting material was purified by high performance liquid chromatography (HPLC) systems ranging from the analytical scale process to a scaleup to 1 g per batch. Three columns (Protein A affinity chromatography with single-step elution, hydroxyapatite (HA) chromatography followed by linear gradient elution and endotoxin removing-gel chromatography), exploiting different properties of the mAb were applied. The final batches of antibody were subjected to a large panel of tests for the purpose of evaluating the efficacy of the downstream processing. The resulting data have allowed us to determine the maximum number of times the column can be used and to precisely and thoroughly characterize antibody integrity, specificity, and potency according to in-house reference standards. The optimized bioprocessing is rapid, efficient, and reproducible. Not less importantly, all the techniques applied are characterized by costs which are affordable to medium-sized laboratories. They represent the basis for implementing immunotherapeutic protocols transferable to clinical medicine.

  10. Differentiated analysis of an everolimus-eluting stent and a paclitaxel-eluting stent among higher risk subgroups for restenosis: results from the SPIRIT II trial.

    PubMed

    Khattab, Ahmed A; Richardt, Gert; Verin, Vitali; Kelbaek, Henning; Macaya, Carlos; Berland, Jacques; Miquel-Hebert, Karine; Dorange, Cécile; Serruys, Patrick W

    2008-03-01

    Restenosis is higher among certain subpopulations when subjected to percutaneous coronary interventions even when using drug-eluting stents. The randomised SPIRIT II trial demonstrated the superiority of the XIENCE V Everolimus Eluting Coronary Stent System over the TAXUS Paclitaxel-Eluting Stent System in terms of in-stent late loss at six months among 300 patients treated for de novo native coronary artery lesions. In this post-hoc analysis of SPIRIT II we focused on six-month angiographic outcomes of diabetic patients (n=69), left anterior descending arteries (n=149), long lesions >20 mm (n=43), small vessels <3.0 mm (n=209) and type B2 and C lesions (n=233). In-stent late loss was consistently less among all subgroups when treated by everolimus-eluting stents compared to paclitaxel-eluting stents: diabetics 0.15+/-0.26 mm versus 0.39+/-0.34 mm, p=0.006; LAD 0.12+/-0.23 mm versus 0.44+/-0.37 mm, p<0.001; long lesions 0.13+/-0.26 mm versus 0.43+/-0.46 mm, p=0.070; small vessels 0.17+/-0.28 mm versus 0.37+/-0.39 mm, p<0.001; B2/C lesions 0.12+/-0.31 mm versus 0.36+/-0.36 mm, p<0.001. The everolimus-eluting stent remained superior in terms of in-stent late loss in a variety of higher risk populations for restenosis compared to the paclitaxel-eluting stent. These analyses were consistent with the in-stent late loss results of the overall SPIRIT II trial population.

  11. Nickel elution properties of contemporary interatrial shunt closure devices.

    PubMed

    Verma, Divya Ratan; Khan, Muhammad F; Tandar, Anwar; Rajasekaran, Namakkal S; Neuharth, Renée; Patel, Amit N; Muhlestein, Joseph B; Badger, Rodney S

    2015-02-01

    We sought to compare nickel elution properties of contemporary interatrial shunt closure devices in vitro. There are two United States Food and Drug Administration (FDA)-approved devices for percutaneous closure of secundum atrial septal defect: the Amplatzer septal occluder (ASO; St Jude Medical Corporation) and Gore Helex septal occluder (HSO; W.L. Gore & Associates). The new Gore septal occluder (GSO) device is in clinical trials. These are also used off-label for patent foramen ovale closure in highly selected patients. These devices have high nickel content. Nickel allergy is the most common reason for surgical device explantation. Nickel elution properties of contemporary devices remain unknown. We compared nickel elution properties of 4 devices - ASO, GSO, HSO, and sternal wire (SW) - while Dulbecco's phosphate-buffered saline (DPBS) served as control. Three samples of each device were submerged in DPBS. Nickel content was measured at 14 intervals over 90 days. Nickel elution at 24 hours, compared to control (0.005 ± 0.0 mg/L), was significantly higher for ASO (2.98 ± 1.65 mg/L; P=.04) and SW (0.03 ± 0.014 mg/L; P=.03). Nickel levels at 90 days, compared to control (0.005 ± 0.0 mg/L) and adjusting for multiple comparisons, were significantly higher for ASO (19.80 ± 2.30 mg/L; P=.01) and similar for HSO (P=.34), GSO (P=.34), and SW (P=.34). ASO had significantly higher nickel elution compared to HSO, GSO, and SW (P=.01). There is substantial variability in nickel elution; devices with less exposed nickel (HSO and GSO) have minimal elution. The safety of low nickel elution devices in patients with nickel allergy needs to be evaluated in prospective trials.

  12. Methods of increasing the performance of radionuclide generators used in nuclear medicine: daughter nuclide build-up optimisation, elution-purification-concentration integration, and effective control of radionuclidic purity.

    PubMed

    Le, Van So; Do, Zoe Phuc-Hien; Le, Minh Khoi; Le, Vicki; Le, Natalie Nha-Truc

    2014-06-10

    Methods of increasing the performance of radionuclide generators used in nuclear medicine radiotherapy and SPECT/PET imaging were developed and detailed for 99Mo/99mTc and 68Ge/68Ga radionuclide generators as the cases. Optimisation methods of the daughter nuclide build-up versus stand-by time and/or specific activity using mean progress functions were developed for increasing the performance of radionuclide generators. As a result of this optimisation, the separation of the daughter nuclide from its parent one should be performed at a defined optimal time to avoid the deterioration in specific activity of the daughter nuclide and wasting stand-by time of the generator, while the daughter nuclide yield is maintained to a reasonably high extent. A new characteristic parameter of the formation-decay kinetics of parent/daughter nuclide system was found and effectively used in the practice of the generator production and utilisation. A method of "early elution schedule" was also developed for increasing the daughter nuclide production yield and specific radioactivity, thus saving the cost of the generator and improving the quality of the daughter radionuclide solution. These newly developed optimisation methods in combination with an integrated elution-purification-concentration system of radionuclide generators recently developed is the most suitable way to operate the generator effectively on the basis of economic use and improvement of purposely suitable quality and specific activity of the produced daughter radionuclides. All these features benefit the economic use of the generator, the improved quality of labelling/scan, and the lowered cost of nuclear medicine procedure. Besides, a new method of quality control protocol set-up for post-delivery test of radionuclidic purity has been developed based on the relationship between gamma ray spectrometric detection limit, required limit of impure radionuclide activity and its measurement certainty with respect to optimising decay/measurement time and product sample activity used for QC quality control. The optimisation ensures a certainty of measurement of the specific impure radionuclide and avoids wasting the useful amount of valuable purified/concentrated daughter nuclide product. This process is important for the spectrometric measurement of very low activity of impure radionuclide contamination in the radioisotope products of much higher activity used in medical imaging and targeted radiotherapy.

  13. Octadecyl functionalized core-shell magnetic silica nanoparticle as a powerful nanocomposite sorbent to extract urinary volatile organic metabolites.

    PubMed

    Qiao, Zheng; Perestrelo, Rosa; Reyes-Gallardo, Emilia M; Lucena, R; Cárdenas, S; Rodrigues, João; Câmara, José S

    2015-05-08

    In this present study, magnetic Fe3O4@SiO2 nanoparticles (MNPs) functionalized with octadecyl groups (Fe3O4@SiO2-C18 NPs) were synthesized, characterized and employed, for the first time, as powerful nanosorbent to extract endogenous volatile organic metabolites (EVOMs) namely, hexanal, heptanal, decanal, benzaldehyde, 4-heptanone, 5-methyl-2-furfural and phenol, described as potential biomarkers of cancer, from human urine. By using co-precipitation, surface modification methods, the carbon-ferromagnetic nanocomposite was synthesized and characterized by infrared spectrum (IR) and transmission electron microscopy (TEM). By coupling with gas chromatography-mass spectrometry (GC-qMS), a reliable, sensitive and cost-effective method was validated. To test the extraction efficiency of the carbon-ferromagnetic nanocomposite toward urinary EVOMs experimental variables affecting the extraction performance, including nanosorbent amount, adsorption time, elution time, and nature of elution solvent, were investigated in detail. The extraction process was performed by dispersing Fe3O4@SiO2-C18 NPs into working solution containing targeted VOMs, and into urine samples, and then eluted with an adequate organic solvent. The eluate was collected, concentrated and analyzed by GC-qMS. Under the optimized conditions, the LODs and LOQs achieved were in the range of 9.7-57.3 and 32.4-190.9ng/mL, respectively. Calibration curves were linear (r(2)≥0. 988) over the concentration ranges from 0.25 to 250ng/mL. In addition, a satisfying reproducibility was achieved by evaluating the intra- and inter-day precisions with relative standard deviations (RSDs) less than 3 and 11%, respectively. The method also afforded satisfactory results in terms of the matrix effect (72.8-96.1%) and recoveries (accuracy) higher than 75.1% for most of the studied EVOMs. The Fe3O4@SiO2-C18 NPs-based sorbent extraction combined with GC-qMS revealed that the new nanosorbent had a strong ability to retain the target metabolites providing a new, reliable and high throughput strategy for isolation of targeted EVOMs in human urine, suggesting their potential to be applied in other EVOMs. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Biotic and abiotic processes controlling water chemistry during snowmelt at rabbit ears pass, Rocky Mountains, Colorado, U.S.A.

    USGS Publications Warehouse

    Peters, N.E.; Leavesley, G.H.

    1995-01-01

    The chemical composition of snowmelt, groundwater, and streamwater was monitored during the spring of 1991 and 1992 in a 200-ha subalpine catchment on the western flank of the Rocky Mountains near Steamboat Springs, Colorado. Most of the snowmelt occurred during a one-month period annually that began in mid-May 1991 and mid-April 1992. The average water quality characteristics of individual sampling sites (meltwater, streamwater, and groundwater) were similar in 1991 and 1992. The major ions in meltwater were differentially eluted from the snowpack, and meltwater was dominated by Ca2+, SO4/2-, and NO3/-. Groundwater and streamwater were dominated by weathering products, including Ca2+, HCO3/- (measured as alkalinity), and SiO2, and their concentrations decreased as snowmelt progressed. One well had extremely high NO3/- concentrations, which were balanced by Ca2+ concentrations. For this well, hydrogen ion was hypothesized to be generated from nitrification in overlying soils, and subsequently exchanged with other cations, particularly Ca2+. Solute concentrations in streamwater also decreased as snowmelt progressed. Variations in groundwater levels and solute concentrations indicate thai most of the meltwater traveled through the surficial materials. A mass balance for 1992 indicated that the watershed retained H+, NH4/+, NO3/-, SO4/2- and Cl- and was the primary source of base cations and other weathering products. Proportionally more SO4/2- was deposited with the unusually high summer rainfall in 1992 compared to that released from snowmelt, whereas NO3/- was higher in snowmelt and Cl- was the same. The sum of snowmelt and rainfall could account for greater than 90% of the H+ and NH4/+ retained by the watershed and greater than 50% of the NO3/-.The chemical composition of snowmelt, groundwater, and streamwater was monitored during the spring of 1991 and 1992 in a 200-ha subalpine catchment on the western flank of the Rocky Mountains near Steamboat Springs, Colorado. The major ions in meltwater were differentially eluted from the snowpack, and meltwater was dominated by Ca2+, SO42-, and NO3-. Groundwater and streamwater were dominated by weathering products and their concentrations decreased as snowmelt progressed. Solute concentrations in streamwater also decreased as snowmelt progressed. A mass balance for 1992 showed that the watershed retained H+, NH4+, NO3-, SO42- and Cl- and was the primary source of base cations and other weathering products.

  15. The best practice for preparation of samples from FTA®cards for diagnosis of blood borne infections using African trypanosomes as a model system.

    PubMed

    Ahmed, Heba A; MacLeod, Ewan T; Hide, Geoff; Welburn, Susan C; Picozzi, Kim

    2011-05-07

    Diagnosis of blood borne infectious diseases relies primarily on the detection of the causative agent in the blood sample. Molecular techniques offer sensitive and specific tools for this although considerable difficulties exist when using these approaches in the field environment. In large scale epidemiological studies, FTA®cards are becoming increasingly popular for the rapid collection and archiving of a large number of samples. However, there are some difficulties in the downstream processing of these cards which is essential for the accurate diagnosis of infection. Here we describe recommendations for the best practice approach for sample processing from FTA®cards for the molecular diagnosis of trypanosomiasis using PCR. A comparison of five techniques was made. Detection from directly applied whole blood was less sensitive (35.6%) than whole blood which was subsequently eluted from the cards using Chelex®100 (56.4%). Better apparent sensitivity was achieved when blood was lysed prior to application on the FTA cards (73.3%) although this was not significant. This did not improve with subsequent elution using Chelex®100 (73.3%) and was not significantly different from direct DNA extraction from blood in the field (68.3%). Based on these results, the degree of effort required for each of these techniques and the difficulty of DNA extraction under field conditions, we recommend that blood is transferred onto FTA cards whole followed by elution in Chelex®100 as the best approach.

  16. Purification of foot-and-mouth disease virus by heparin as ligand for certain strains.

    PubMed

    Du, Ping; Sun, Shiqi; Dong, Jinjie; Zhi, Xiaoying; Chang, Yanyan; Teng, Zhidong; Guo, Huichen; Liu, Zaixin

    2017-04-01

    The goal of this project was to develop an easily operable and scalable process for the recovery and purification of foot-and-mouth disease virus (FMDV) from cell culture. Heparin resins HipTrap Heparin HP and AF-Heparin HC-650 were utilized to purify FMDV O/HN/CHA/93. Results showed that the purity of AF-Heparin HC-650 was ideal. Then, the O/HN/CHA/93, O/Tibet/CHA/99, Asia I/HN/06, and A/CHA/HB/2009 strains were purified by AF-Heparin HC-650. Their affinity/virus recoveries were approximately 51.2%/45.8%, 71.5%/70.9%, 96.4%/73.5, and 59.5%/42.1%, respectively. During a stepwise elution strategy, the viral particles were mainly eluted at 300mM ionic strength peaks. The heparin affinity chromatography process removed more than 94% of cellular and medium proteins. Anion exchange resin Capto Q captured four FMD virus particles; 40% of binding proteins and 80%-90% of viral particles were eluted at 450mM NaCl. Moreover, ionic strength varied from 30 to 450mM had no effect on the immunity to FMDV. The results revealed that heparin sulfate may be the main receptor for CHA/99 strain attachment-susceptible cells. Heparin affinity chromatography can reach perfect results, especially when used as a ligand of the virus. Anion exchange is useful only as previous step for further purification. Copyright © 2016. Published by Elsevier B.V.

  17. My Interventional Drug-Eluting Stent Educational App (MyIDEA): Patient-Centered Design Methodology

    PubMed Central

    Shroff, Adhir; Groo, Vicki; Dickens, Carolyn; Field, Jerry; Baumann, Matthew; Welland, Betty; Gutowski, Gerry; Flores Jr, Jose D; Zhao, Zhongsheng; Bahroos, Neil; Hynes, Denise M; Wilkie, Diana J

    2015-01-01

    Background Patient adherence to medication regimens is critical in most chronic disease treatment plans. This study uses a patient-centered tablet app, “My Interventional Drug-Eluting Stent Educational App (MyIDEA).” This is an educational program designed to improve patient medication adherence. Objective Our goal is to describe the design, methodology, limitations, and results of the MyIDEA tablet app. We created a mobile technology-based patient education app to improve dual antiplatelet therapy adherence in patients who underwent a percutaneous coronary intervention and received a drug-eluting stent. Methods Patient advisers were involved in the development process of MyIDEA from the initial wireframe to the final launch of the product. The program was restructured and redesigned based on the patient advisers’ suggestions as well as those from multidisciplinary team members. To accommodate those with low health literacy, we modified the language and employed attractive color schemes to improve ease of use. We assumed that the target patient population may have little to no experience with electronic tablets, and therefore, we designed the interface to be as intuitive as possible. Results The MyIDEA app has been successfully deployed to a low-health-literate elderly patient population in the hospital setting. A total of 6 patients have interacted with MyIDEA for an average of 17.6 minutes/session. Conclusions Including patient advisers in the early phases of a mobile patient education development process is critical. A number of changes in text order, language, and color schemes occurred to improve ease of use. The MyIDEA program has been successfully deployed to a low-health-literate elderly patient population. Leveraging patient advisers throughout the development process helps to ensure implementation success. PMID:26139587

  18. Solid-phase extraction of some heavy metal ions on a double-walled carbon nanotube disk and determination by flame atomic absorption spectrometry.

    PubMed

    Karatepe, Aslihan; Soylak, Mustafa; Elçi, Latif

    2011-01-01

    A new preconcentration method was developed for the determination of trace amounts of Cu(II), Fe(III), Pb(II), Ni(II), and Cd(II) on a double-walled carbon nanotube disk. 4-(2-Thiazolylazo) resorcinol was used as a complexing reagent. The effects of parameters, including pH of the solutions, amounts of complexing reagent, eluent type, sample volume, flow rates of solutions, and matrix ions were examined for quantitative recoveries of the studied analyte ions. The retained metal ions were eluted by 2 M HNO3. The LOD values for the analytes were in the range of 0.7-4.4 microg/mL. Natural water samples and standard reference materials were analyzed by the presented method.

  19. Facile purification and click labeling with 2-[ 18F]fluoroethyl azide using solid phase extraction cartridges

    DOE PAGES

    Zhou, Dong; Chu, Wenhua; Peng, Xin; ...

    2014-11-04

    In this paper, a facile method was developed to purify 2-[ 18F]fluoroethyl azide ([ 18F]FEA) using a C18 cartridge and an Oasis® HLB cartridge in series, in which [18F]FEA was exclusively trapped on the HLB cartridge. [ 18F]FEA can be eluted for reactions in solution; alternatively click labeling can be carried out on the HLB cartridge itself by loading an alkyne substrate and copper (I) catalyst dissolved in DMF onto the cartridge. Finally, this solid phase extraction methodology for purification and click labeling with [ 18F]FEA, either in solution or on the cartridge, is safe, simple, reproducible in high yield,more » and compatible with automated synthesis of 18F-labeled PET tracers.« less

  20. MC ICP-MS δ(34)S(VCDT) measurement of dissolved sulfate in environmental aqueous samples after matrix separation by means of an anion exchange membrane.

    PubMed

    Hanousek, Ondrej; Berger, Torsten W; Prohaska, Thomas

    2016-01-01

    Analysis of (34)S/(32)S of sulfate in rainwater and soil solutions can be seen as a powerful tool for the study of the sulfur cycle. Therefore, it is considered as a useful means, e.g., for amelioration and calibration of ecological or biogeochemical models. Due to several analytical limitations, mainly caused by low sulfate concentration in rainwater, complex matrix of soil solutions, limited sample volume, and high number of samples in ecosystem studies, a straightforward analytical protocol is required to provide accurate S isotopic data on a large set of diverse samples. Therefore, sulfate separation by anion exchange membrane was combined with precise isotopic measurement by multicollector inductively coupled plasma mass spectrometry (MC ICP-MS). The separation method proved to be able to remove quantitatively sulfate from matrix cations (Ca, K, Na, or Li) which is a precondition in order to avoid a matrix-induced analytical bias in the mass spectrometer. Moreover, sulfate exchange on the resin is capable of preconcentrating sulfate from low concentrated solutions (to factor 3 in our protocol). No significant sulfur isotope fractionation was observed during separation and preconcentration. MC ICP-MS operated at edge mass resolution has enabled the direct (34)S/(32)S analysis of sulfate eluted from the membrane, with an expanded uncertainty U (k = 2) down to 0.3 ‰ (a single measurement). The protocol was optimized and validated using different sulfate solutions and different matrix compositions. The optimized method was applied in a study on solute samples retrieved in a beech (Fagus sylvatica) forest in the Vienna Woods. Both rainwater (precipitation and tree throughfall) and soil solution δ (34)SVCDT ranged between 4 and 6 ‰, the ratio in soil solution being slightly lower. The lower ratio indicates that a considerable portion of the atmospherically deposited sulfate is cycled through the organic S pool before being released to the soil solution. Nearly the same trends and variations were observed in soil solution and rainwater δ (34)SVCDT values showing that sulfate adsorption/desorption are not important processes in the studied soil.

  1. ADSORPTION-BISMUTH PHOSPHATE METHOD FOR SEPARATING PLUTONIUM

    DOEpatents

    Russell, E.R.; Adamson, A.W.; Boyd, G.E.

    1960-06-28

    A process is given for separating plutonium from uranium and fission products. Plutonium and uranium are adsorbed by a cation exchange resin, plutonium is eluted from the adsorbent, and then, after oxidation to the hexavalent state, the plutonium is contacted with a bismuth phosphate carrier precipitate.

  2. Separation of mutagenic components in synthetic crudes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Guerin, M. R.; Ho, C. H.; Clark, B. R.

    1978-01-01

    Mutagenic, basic constituents of a synthetic coal oil and a shale oil were isolated from the crude mixtures. In arriving at an efficient isolation procedure, several liquid chromatographic packing-eluent combinations were tried and the fractions bioassayed to determine the distributions of the mutagenic components. The most effective separation was achieved using a sequential elution scheme with first an alumina-benzene combination followed by a Sephadex LH-20 gel-isopropanol-acetone system. About 75 to 80% of an ether soluble base is eluted with benzene through alumina (activity I). Analysis of this fraction has revealed a wide range of alkyl substituted quinolines and pyridines. Materialmore » remaining on the alumina column was eluted with ethanol, dried and placed on the Sephadex column. Isopropanol (approximately 250 ml) and acetone (approximately 600 ml) were used in that order to elute the material quantitatively. About 12% of the ether-soluble base is eluted with the isopropanol while the rest (approximately 10%) is eluted with the acetone. Additional alkyl pyridine compounds are eluted with isopropanol while the acetone fractions are predominantly multi-ring nitrogen heterocyclic compounds, according to mass spectral analyses. Bioassay data show excellent isolation of the mutagenic activities into the acetone fractions. Negligible activity is found in the sum of the other (90% wt) fractions.« less

  3. Laboratory study of the response of select insecticides to toxicity identification evaluation procedures

    USGS Publications Warehouse

    Kuivila, Kathryn; Crepeau, Kathryn L.

    1999-01-01

    A laboratory study was used to evaluate the response of select insecticides to toxicity identification evaluation procedures. Fourteen insecticides, one degradation product, and one synergist were spiked into organic-grade water and carried through toxicity identification evaluation procedures. Concentrations of each compound were analyzed by gas chromatography/mass spectrometry. During Phase I, the water sample was pumped through a C-8 solid-phase extraction cartridge and then eluted with methanol. Dimethoate was not removed by the extraction, but remained in the rinsate. In contrast, permethrin was removed by the extraction, but was not recovered by the methanol elution, and 80 percent of the permethrin remained on the cartridge, teflon tubing, and glassware. Chlorpyrifos also was not recovered completely with the methanol elution (only 62 percent was recovered). The other insecticides were extracted by C-8 solid-phase extraction cartridge and recovered by elution with methanol (80 percent or greater). During Phase II, a new spiked water sample was extracted by C-8 solid-phase extraction cartridge and then eluted with varying concentrations of methanol and water into different fractions. Each methanol:water fraction was analyzed for the added compounds. Most of the insecticides eluted in two fractions, with concentrations of 10 percent or greater. The largest number of insecticides eluted in the 75 percent methanol:water fraction.

  4. Concentration and fractionation of hydrophobic organic acid constituents from natural waters by liquid chromatography

    USGS Publications Warehouse

    Thurman, E.M.; Malcolm, R.L.

    1979-01-01

    A scheme is presented which used adsorption chromatography with pH gradient elution and size-exclusion chromatography to concentrate and separate hydrophobic organic acids from water. A review of chromatographic processes involved in the flow scheme is also presented. Organic analytes which appear in each aqueous fraction are quantified by dissolved organic carbon analysis. Hydrophobic organic acids in a water sample are concentrated on a porous acrylic resin. These acids usually constitute approximately 30-50 percent of the dissolved organic carbon in an unpolluted water sample and are eluted with an aqueous eluent (dilute base). The concentrate is then passed through a column of polyacryloylmorpholine gel, which separates the acids into high- and low-molecular-weight fractions. The high- and low-molecular-weight eluates are reconcentrated by adsorption chromatography, then are eluted with a pH gradient into strong acids (predominately carboxylic acids) and weak acids (predominately phenolic compounds). For standard compounds and samples of unpolluted waters, the scheme fractionates humic substances into strong and weak acid fractions that are separated from the low molecular weight acids. A new method utilizing conductivity is also presented to estimate the acidic components in the methanol fraction.

  5. Rapid analysis of charge variants of monoclonal antibodies using non-linear salt gradient in cation-exchange high performance liquid chromatography.

    PubMed

    Joshi, Varsha; Kumar, Vijesh; Rathore, Anurag S

    2015-08-07

    A method is proposed for rapid development of a short, analytical cation exchange high performance liquid chromatography method for analysis of charge heterogeneity in monoclonal antibody products. The parameters investigated and optimized include pH, shape of elution gradient and length of the column. It is found that the most important parameter for development of a shorter method is the choice of the shape of elution gradient. In this paper, we propose a step by step approach to develop a non-linear sigmoidal shape gradient for analysis of charge heterogeneity for two different monoclonal antibody products. The use of this gradient not only decreases the run time of the method to 4min against the conventional method that takes more than 40min but also the resolution is retained. Superiority of the phosphate gradient over sodium chloride gradient for elution of mAbs is also observed. The method has been successfully evaluated for specificity, sensitivity, linearity, limit of detection, and limit of quantification. Application of this method as a potential at-line process analytical technology tool has been suggested. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. A biodegradable antibiotic-eluting PLGA nanofiber-loaded deproteinized bone for treatment of infected rabbit bone defects.

    PubMed

    Gao, Jianting; Huang, Guofeng; Liu, Guojun; Liu, Yan; Chen, Qi; Ren, Lei; Chen, Changqing; Ding, Zhenqi

    2016-08-01

    We fabricated a biodegradable antibiotic-eluting poly(d,l)-lactide-co-glycolide nanofiber-loaded deproteinized bone (ANDB) scaffold that provided sustained delivery of vancomycin to repair methicillin-resistant Staphylococcus aureus bone defects. To fabricate the biodegradable ANDB, poly(d,l)-lactide-co-glycolide and vancomycin were first dissolved in 1,1,1,3,3,3-hexafluoro-2-propano. The solution was then electrospun to produce biodegradable antibiotic-eluting membranes that were deposited on the surface of bovine deproteinized cancellous bone. We used scanning electron microscopy to determine the properties of the scaffold. Both elution and high-performance liquid chromatography assays were used to evaluate the in vitro vancomycin release rate from the ANDB scaffold. Three types of scaffolds were co-cultured with bacteria to confirm the in vitro antibacterial activity. The infected bone defect rabbit model was induced by injecting 10(7) colony forming units of a methicillin-resistant Staphylococcus aureus strain into the radial defect of rabbits. Animals were then separated into treatment groups and implanted according to the following scheme: ANDB scaffold in group A, poly(d,l)-lactide-co-glycolide nanofiber-loaded deproteinized bone (NDB) scaffold with intravenous (i.v.) vancomycin in group B, and NDB scaffold alone in group C. Treatment efficacy was evaluated after eight weeks using radiological, microbiological, and histological examinations. In vitro results revealed that biodegradable ANDB scaffolds released concentrations of vancomycin that were greater than the minimum inhibitory concentration for more than four weeks. Bacterial inhibition tests also confirmed antibacterial efficacy lasted for approximately four weeks. Radiological and histological scores obtained in vivo revealed significant differences between groups A, B and C. Importantly, group A had significantly lower bacterial load and better bone regeneration when compared to either group B or C. Collectively, these results show that our fabricated ANDB scaffolds possess: (1) effective bactericidal activity against methicillin-resistant Staphylococcus aureus, (2) the ability to promote site-specific bone regeneration, and (3) the potential for use in the treatment of infected bone defects. © The Author(s) 2016.

  7. Development and characterization of a carbon-based composite material for reducing patulin levels in apple juice.

    PubMed

    Huebner, H J; Mayura, K; Pallaroni, L; Ake, C L; Lemke, S L; Herrera, P; Phillips, T D

    2000-01-01

    Patulin, a heterocyclic lactone produced by various species of Penicillium and Aspergillus fungi, is often detected in apple juices and ciders. Previous research has shown the effectiveness of granular activated carbon for reducing patulin levels in aqueous solutions, apple juices, and ciders. In this study, ultrafine activated carbon was bonded onto granular quartz to produce a composite carbon adsorbent (CCA) with a high carbonaceous surface area, good bed porosity, and increased bulk density. CCA in fixed-bed adsorption columns was evaluated for efficacy in reducing patulin levels from aqueous solutions and apple juice. Columns containing 1.0, 0.5, and 0.25 g of CCA were continuously loaded with a patulin solution (10 microg/ml) and eluted at a flow rate of 1 ml/min. Results indicated that 50% breakthrough capacities for patulin on 1.0-, 0.5-, and 0.25-g CCA columns were 137.5, 38.5, and 19.9 microg, respectively. The effectiveness of CCA to adsorb patulin and prevent toxic effects was confirmed in vitro using adult hydra in culture. Hydra were sensitive to the effects of patulin, with a minimal affective concentration equal to 0.7 microg/ml; CCA adsorption prevented patulin toxicity until 76% breakthrough capacity was achieved. Fixed-bed adsorption with 1.0 g of CCA was also effective in reducing patulin concentrations (20 microg/liter) in a naturally contaminated apple juice, and breakthrough capacities were shown to increase with temperature. Additionally, CCA offered a higher initial breakthrough capacity than pelleted activated carbon when compared in parallel experiments. This study suggests that CCA used in fixed-bed adsorption systems effectively reduced patulin levels in both aqueous solutions and naturally contaminated apple juice; however, the appearance and taste of apple juice may be affected by the treatment process.

  8. LITERATURE REVIEW FOR OXALATE OXIDATION PROCESSES AND PLUTONIUM OXALATE SOLUBILITY

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nash, C.

    2012-02-03

    A literature review of oxalate oxidation processes finds that manganese(II)-catalyzed nitric acid oxidation of oxalate in precipitate filtrate is a viable and well-documented process. The process has been operated on the large scale at Savannah River in the past, including oxidation of 20 tons of oxalic acid in F-Canyon. Research data under a variety of conditions show the process to be robust. This process is recommended for oxalate destruction in H-Canyon in the upcoming program to produce feed for the MOX facility. Prevention of plutonium oxalate precipitation in filtrate can be achieved by concentrated nitric acid/ferric nitrate sequestration of oxalate.more » Organic complexants do not appear practical to sequester plutonium. Testing is proposed to confirm the literature and calculation findings of this review at projected operating conditions for the upcoming campaign. H Canyon plans to commence conversion of plutonium metal to low-fired plutonium oxide in 2012 for eventual use in the Mixed Oxide Fuel (MOX) Facility. The flowsheet includes sequential operations of metal dissolution, ion exchange, elution, oxalate precipitation, filtration, and calcination. All processes beyond dissolution will occur in HB-Line. The filtration step produces an aqueous filtrate that may have as much as 4 M nitric acid and 0.15 M oxalate. The oxalate needs to be removed from the stream to prevent possible downstream precipitation of residual plutonium when the solution is processed in H Canyon. In addition, sending the oxalate to the waste tank farm is undesirable. This report addresses the processing options for destroying the oxalate in existing H Canyon equipment.« less

  9. Everolimus-eluting bioresorbable vascular scaffolds versus everolimus-eluting metallic stents: a meta-analysis of randomised controlled trials.

    PubMed

    Cassese, Salvatore; Byrne, Robert A; Ndrepepa, Gjin; Kufner, Sebastian; Wiebe, Jens; Repp, Janika; Schunkert, Heribert; Fusaro, Massimiliano; Kimura, Takeshi; Kastrati, Adnan

    2016-02-06

    Bioresorbable coronary stents might improve outcomes of patients treated with percutaneous coronary interventions. The everolimus-eluting bioresorbable vascular scaffold is the most studied of these stent platforms; however, its performance versus everolimus-eluting metallic stents remains poorly defined. We aimed to assess the efficacy and safety of everolimus-eluting bioresorbable vascular scaffolds versus everolimus-eluting metallic stents in patients with ischaemic heart disease treated with percutaneous revascularisation. We searched Medline, Embase, the Cochrane Central Register of Controlled Trials (CENTRAL), scientific sessions abstracts, and relevant websites for randomised trials investigating everolimus-eluting bioresorbable vascular scaffolds versus everolimus-eluting metallic stents published or posted between Nov 30, 2006, and Oct 12, 2015. The primary efficacy outcome was target lesion revascularisation and the primary safety outcome was definite or probable stent (scaffold) thrombosis. Secondary outcomes were target lesion failure (the composite of cardiac death, target-vessel myocardial infarction, or ischaemia-driven target lesion revascularisation), myocardial infarction, death, and in-device late lumen loss. We derived odds ratios (ORs) and weighted mean differences with 95% CIs, and calculated the risk estimates for the main outcomes according to a random-effects model. This study is registered with PROSPERO, number CRD42015026374. We included six trials, comprising data for 3738 patients randomised to receive percutaneous coronary intervention with either an everolimus-eluting bioresorbable vascular scaffold (n=2337) or an everolimus-eluting metallic stent (n=1401). Median follow-up was 12 months (IQR 9-12). Patients treated with bioresorbable vascular scaffolds had a similar risk of target lesion revascularisation (OR 0.97 [95% CI 0.66-1.43]; p=0.87), target lesion failure (1.20 [0.90-1.60]; p=0.21), myocardial infarction (1.36 [0.98-1.89]; p=0.06), and death (0.95 [0.45-2.00]; p=0.89) as those treated with metallic stents. Patients treated with a bioresorbable vascular scaffold had a higher risk of definite or probable stent thrombosis than those treated with a metallic stent (OR 1.99 [95% CI 1.00-3.98]; p=0.05), with the highest risk between 1 and 30 days after implantation (3.11 [1.24-7.82]; p=0.02). Lesions treated with a bioresorbable vascular scaffold had greater in-device late lumen loss than those treated with a metallic stent (weighted mean difference 0.08 [95% CI 0.05-0.12]; p<0.0001). Compared with everolimus-eluting metallic stents, everolimus-eluting bioresorbable vascular scaffolds had similar rates of repeat revascularisation at 1 year of follow-up, despite inferior mid-term angiographic performance. However, patients treated with a bioresorbable vascular scaffold had an increased risk of subacute stent thrombosis. Studies with extended follow-up in a larger number of patients are needed to fully assess the long-term advantages of everolimus-eluting bioresorbable vascular scaffolds. None. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. Selective recovery of minor trivalent actinides from high level liquid waste by R-BTP/SiO2-P adsorbents

    NASA Astrophysics Data System (ADS)

    Sano, Yuichi; Surugaya, Naoki; Yamamoto, Masahiko

    2010-03-01

    Concerning the selective recovery of minor trivalent actinides (MA(III) = Am(III) and Cm(III)) from high level liquid waste (HLLW) by extraction chromatography, adsorption and elution behaviours of MA(III) and fission products (FP) in a nitric acid media were studied using iHex-BTP/SiO2-P adsorbents, which is expected to show high adsorption affinity for MA(III) even in concentrated HNO3 solution, such as HLLW. In the batch experiments, Pd showed strong adsorption on iHex-BTP/SiO2-P adsorbents under any concentration of HNO3. The MA(III) and heavy Ln(III) (Sm(III), Eu(III) and Gd(III)) were also adsorbed at the condition of high HNO3 concentration, but they showed no adsorption under low HNO3concentration. The separation factor for MA(III)/heavy Ln(III) took the maximum value (over 100) at around 1mol/dm3 HNO3. It was difficult to elute MA(III) or heavy Ln(III) selectively by HNO3 from the iHex-BTP/SiO2-P adsorbents degradated by γ-ray irradiation. The chromatographic separation of real HLLW by an iHex-BTP/SiO2-P column showed that MA(III) could be recovered selectively by adjusting the acidity of the feed solution, i.e. HLLW, to 1mol/dm3 and using H2O as eluant. The adsorption of Pd(II) can be decreased by the addition of appropriate complexing reagents, e.g. DTPA, into HLLW without any effects on the MA(III) adsorption.

  11. Magnetic graphene oxide modified with choline chloride-based deep eutectic solvent for the solid-phase extraction of protein.

    PubMed

    Huang, Yanhua; Wang, Yuzhi; Pan, Qi; Wang, Ying; Ding, Xueqin; Xu, Kaijia; Li, Na; Wen, Qian

    2015-06-02

    Four kinds of green deep eutectic solvents (DESs) based on choline chloride (ChCl) have been synthesized and coated on the surface of magnetic graphene oxide (Fe3O4@GO) to form Fe3O4@GO-DES for the magnetic solid-phase extraction of protein. X-ray diffraction (XRD), vibrating sample magnetometer (VSM), Fourier transform infrared spectrometry (FTIR), field emission scanning electron microscopy (FESEM) and thermal gravimetric analysis (TGA) were employed to characterize Fe3O4@GO-DES, and the results indicated the successful preparation of Fe3O4@GO-DES. The UV-vis spectrophotometer was used to measure the concentration of protein after extraction. Single factor experiments proved that the extraction amount was influenced by the types of DESs, solution temperature, solution ionic strength, extraction time, protein concentration and the amount of Fe3O4@GO-DES. Comparison of Fe3O4@GO and Fe3O4@GO-DES was carried out by extracting bovine serum albumin, ovalbumin, bovine hemoglobin and lysozyme. The experimental results showed that the proposed Fe3O4@GO-DES performs better than Fe3O4@GO in the extraction of acidic protein. Desorption of protein was carried out by eluting the solid extractant with 0.005 mol L(-1) Na2HPO4 contained 1 mol L(-1) NaCl. The obtained elution efficiency was about 90.9%. Attributed to the convenient magnetic separation, the solid extractant could be easily recycled. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. In vitro physical, chemical, and biological evaluation of commercially available metal orthodontic brackets.

    PubMed

    Kim, Joo Hyoung; Cha, Jung Yul; Hwang, Chung Ju

    2012-12-01

    This in vitro study was undertaken to evaluate the physical, chemical, and biological properties of commercially available metal orthodontic brackets in South Korea, because national standards for these products are lacking. FOUR BRACKET BRANDS WERE TESTED FOR DIMENSIONAL ACCURACY, (MANUFACTURING ERRORS IN ANGULATION AND TORQUE), CYTOTOXICITY, COMPOSITION, ELUTION, AND CORROSION: Archist (Daeseung Medical), Victory (3M Unitek), Kosaka (Tomy), and Confidence (Shinye Odontology Materials). The tested rackets showed no significant differences in manufacturing errors in angulation, but Confidence brackets showed a significant difference in manufacturing errors in torque. None of the brackets were cytotoxic to mouse fibroblasts. The metal ion components did not show a regular increasing or decreasing trend of elution over time, but the volume of the total eluted metal ions increased: Archist brackets had the maximal Cr elution and Confidence brackets appeared to have the largest volume of total eluted metal ions because of excessive Ni elution. Confidence brackets showed the lowest corrosion resistance during potentiodynamic polarization. The results of this study could potentially be applied in establishing national standards for metal orthodontic brackets and in evaluating commercially available products.

  13. Contrasting Effects of Physical Wear on Elution of Two Antibiotics from Orthopedic Cement

    PubMed Central

    Dodds, S.; Akid, R.; Stephenson, J.; Nichol, T.; Banerjee, R. D.; Stockley, I.; Townsend, R.

    2012-01-01

    The use of antibiotics as a supplement to bone cement for the purposes of providing a local release of antibiotics is common practice in arthroplasty surgery and the kinetics of elution of the antibiotics in such systems have been investigated previously. However, in these previous studies no account was taken of the potential effects that wear may have on the elution kinetics of the antibiotic. Here, we have modified an existing wear testing rig to allow the simultaneous study of the elution kinetics of bone cement samples containing antibiotics being subjected to immersion only and immersion and conjoint wear. The results show contrasting effects with two commonly used antibiotics. Bone cement containing daptomycin showed no substantial change in antibiotic elution due to wear, while cement containing gentamicin (the most commonly used antibiotic in this application) in contrast demonstrated a substantial reduction in the rate of antibiotic elution when wear was applied. Scanning electron microscopy revealed a possible explanation for these diverse results, due to wear-induced “sealing” of the surface in conjunction with the crystal morphology of the antibiotic. PMID:22155831

  14. Simple flow injection colorimetric system for determination of paraquat in natural water.

    PubMed

    Chuntib, Prakit; Jakmunee, Jaroon

    2015-11-01

    A simple and low cost flow injection colorimetric system has been developed for determination of paraquat in natural water. The developed method is based on the reduction of paraquat by using sodium dithionite as a reducing agent in an alkaline medium to produce a blue free radical ion that can be detected by a simple light emitting diode-light dependent resistor (LED-LDR) colorimeter. The standard or sample solution was injected via a set of 3-way solenoid valves into a water carrier stream and flowed to merge with reagent to generate a colored product which is proportional to the concentration of paraquat ion in the solution. Under the optimum condition of the system, i.e., mixing coil length 30 cm, flow rate 2.0 mL min(-1), sample volume 100 μL, concentrations of dithionite 0.1% (w/v) and sodium hydroxide 0.06 mol L(-1), a linear calibration graph in the range of 0.2-10.0 mg L(-1) with a correlation coefficient of 0.9996, and a limit of detection of 0.15 mg L(-1) were achieved. Relative standard deviation for 9 replicate injections of 1 mg L(-1) paraquat is 3.7%. A sample throughput of 40 injections h(-1) was achieved. The limit of detection can be improved by off-line preconcentration of paraquat employing a column packed with Dowex 50WX8-100 (H) cation exchange resin and eluted with 10% (w/v) ammonium chloride in ammonium buffer solution pH 10. The eluting solution was then injected into the FI system for paraquat determination. The proposed system did not suffer from interferences of some possible ions in natural water and other herbicides. Recoveries obtained by spiking 0.5 and 5.0 mg L(-1) paraquat standard into water samples were in the range of 104-110% and 101-105%, respectively. The developed system can be conveniently applied for screening of paraquat contaminated in natural water. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. Hydrodistillation time affects dill seed essential oil yield, composition, and bioactivity

    USDA-ARS?s Scientific Manuscript database

    Dill (Anethum graveolens L.) essential oil is widely used by the food and pharmaceutical industries. We hypothesized that the chemical constituents of dill seed essential oil are eluted at different times during the hydrodistillation process, resulting in oils with different composition and bioactiv...

  16. Design and characterization of a prototype enzyme microreactor: quantification of immobilized transketolase kinetics.

    PubMed

    Matosevic, S; Lye, G J; Baganz, F

    2010-01-01

    In this work, we describe the design of an immobilized enzyme microreactor (IEMR) for use in transketolase (TK) bioconversion process characterization. The prototype microreactor is based on a 200-microm ID fused silica capillary for quantitative kinetic analysis. The concept is based on the reversible immobilization of His(6)-tagged enzymes via Ni-NTA linkage to surface derivatized silica. For the initial microreactor design, the mode of operation is a stop-flow analysis which promotes higher degrees of conversion. Kinetics for the immobilized TK-catalysed synthesis of L-erythrulose from substrates glycolaldehyde (GA) and hydroxypyruvate (HPA) were evaluated based on a Michaelis-Menten model. Results show that the TK kinetic parameters in the IEMR (V(max(app)) = 0.1 +/- 0.02 mmol min(-1), K(m(app)) = 26 +/- 4 mM) are comparable with those measured in free solution. Furthermore, the k(cat) for the microreactor of 4.1 x 10(5) s(-1) was close to the value for the bioconversion in free solution. This is attributed to the controlled orientation and monolayer surface coverage of the His(6)-immobilized TK. Furthermore, we show quantitative elution of the immobilized TK and the regeneration and reuse of the derivatized capillary over five cycles. The ability to quantify kinetic parameters of engineered enzymes at this scale has benefits for the rapid and parallel evaluation of evolved enzyme libraries for synthetic biology applications and for the generation of kinetic models to aid bioconversion process design and bioreactor selection as a more efficient alternative to previously established microwell-based systems for TK bioprocess characterization.

  17. Radiochemical Applications of Insoluble Sulfate Columns. Analytical Possibilities in the Field of the Fission Product Solutions; APLICACIONES RADIO-QUIMICAS DE LAS COLUMNAS DE PRECIPITADOS DE SULFATOS INSOLUBLES. CONTRIBUCION AL ESTUDIO DE LAS SOLUCIONES ENVEJECIDAS DE PRODUCTOS DE FISION

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barrachina, M.; Sauvagnac, R.

    1962-01-01

    The heterogeneous ion-isotopic exchange column is used to determine the radiochemical composition of raw solutions used in the industrial recuperation of long-lived fission products, The separation of the radioelements is made by small columns, 1--3 cm height, of BaSO/sub 4/ or SrSO/sub 4/, under selected experimental conditions. These columns behave like inorganic exchangers, working by adsorption or ion-isotopic exchange depending on the cases, and they provide selective separation of fission products employing very small volumes of fixing and eluting solutions. By coupling the separative capabilities of these columns and the liquid--liquid extraction with the 2-thenoyltrifluoroacetone and the di-2 ethylexyl orthophosphoricmore » acid, a set of new radiochemical methods, for the determination of Sr/sup 90/, Y/sup 90/, Ce/sup 144/ - Pr/sup 144/, and Pm/sup 147/ in the fission product solutions of Marcoule, were developed. (auth)« less

  18. [Extraction, isolation and purification for ginkgolide B].

    PubMed

    Zhang, Chenfeng; Li, Minghui; Tang, Yun; Zhang, Yanhai; Shi, Min; Sheng, Longsheng

    2010-08-01

    To establish a simple extraction, isolation and purification method for ginkgolide B from ginkgo leaf. The optimum conditions of extraction, isolation and purification were studied by taking the transfer rate of ginkgolide B as index. Ginkgo leaf was extracted with 70% ethanol for three times, the extracts were concentrated to remove ethanol and diluted by water till the crude drug density reached 0.1 g x mL(-1). The dilution was adsorbed with HPD-450 macroporous resin. The impurities were eluted with 20% ethanol and ginkgolide B was eluted with 80% ethanol. Then the 80% ethanol eluant was concentrated and crystallized. Finally the crude crystals were recrystallized with isopropanol. The purity of the ginkgolide B recrystallization was 95%. The process was stable and easy to operate, which was suited to industrialized production.

  19. Development of the chromatographic partitioning of cesium and strontium utilizing two macroporous silica-based calix[4]arene-crown and amide impregnated polymeric composites: PREC partitioning process.

    PubMed

    Zhang, Anyun; Kuraoka, Etsushu; Kumagai, Mikio

    2007-07-20

    To partition effectively Cs(I) and Sr(II), two harmful heat emitting nuclides, from a highly active liquid waste by extraction chromatography, two kinds of macroporous silica-based polymeric materials, Calix[4]arene-R14/SiO(2)-P and TODGA/SiO(2)-P, were synthesized. Two chelating agents, 1,3-[(2,4-diethyl-heptylethoxy)oxy]-2,4-crown-6-calix[4]arene (Calix[4]arene-R14), an excellent supramolecular compound having molecular recognition ability for Cs(I), and N,N,N',N'-tetraoctyl-3-oxapentane-1,5-diamide (TODGA) were impregnated and immobilized into the pores of SiO(2)-P particles support by a vacuum sucking technique. The loading and elution of 11 typical simulated fission and non-fission products from 4.0M or 2.0M HNO(3) were performed at 298K. It was found that in the first column packed with the Calix[4]arene-R14/SiO(2)-P, all of the simulated elements were separated effectively into two groups: (1) Na(I), K(I), Sr(II), Fe(III), Ba(II), Ru(III), Pd(II), Zr(IV), and Mo(VI) (noted as Sr-group); (2) Cs(I)-Rb(I) (Cs-group) by eluting with 4.0M HNO(3) and distilled water, respectively. The harmful element Cs(I) flowed into the second group along with Rb(I) because of their close sorption and elution properties towards Calix[4]arene-R14/SiO(2)-P, while Sr(II) showed no sorption and flowed into Sr-containing group. In the second column packed with TODGA/SiO(2)-P, the Sr-group was separated into (1) Ba(II), Ru(III), Na(I), K(I), Fe(III), and Mo(VI) (non-sorption group); (2) Sr(II); (3) Pd(II); and (4) Zr(IV) by eluting with 2.0M HNO(3), 0.01M HNO(3), 0.05M DTPA-pH 2.5, and 0.5M H(2)C(2)O(4), respectively. Sr(II) adsorbed towards TODGA/SiO(2)-P flowed into the second group and showed the excellent separation efficiency from others. Based on the elution behavior of the tested elements, an advanced PREC (Partitioning and Recovery of two heat generators from an acidic HLW (high activity liquid waste) by Extraction Chromatography) process was proposed.

  20. Evaluation of three methods for the concentration of poliovirus from oysters.

    PubMed

    Bouchriti, N; Goyal, S M

    1992-10-01

    Three methods for the concentration of poliovirus from oyster homogenates were compared. The adsorption-elution-precipitation method gave the lowest average virus recovery (24.1%), while the beef extract elution-acid precipitation method and the non-fat dry milk elution-acid precipitation methods gave recoveries of 47.2% and 39.6%, respectively. Although the overall recovery rates with these methods were lower than those reported in previous studies, recoveries of 40-47% obtained with the elution-precipitation methods used in the present study are considered to be above average in terms of recovery efficiency.

  1. Stent thrombosis with drug-eluting and bare-metal stents: evidence from a comprehensive network meta-analysis.

    PubMed

    Palmerini, Tullio; Biondi-Zoccai, Giuseppe; Della Riva, Diego; Stettler, Christoph; Sangiorgi, Diego; D'Ascenzo, Fabrizio; Kimura, Takeshi; Briguori, Carlo; Sabatè, Manel; Kim, Hyo-Soo; De Waha, Antoinette; Kedhi, Elvin; Smits, Pieter C; Kaiser, Christoph; Sardella, Gennaro; Marullo, Antonino; Kirtane, Ajay J; Leon, Martin B; Stone, Gregg W

    2012-04-14

    The relative safety of drug-eluting stents and bare-metal stents, especially with respect to stent thrombosis, continues to be debated. In view of the overall low frequency of stent thrombosis, large sample sizes are needed to accurately estimate treatment differences between stents. We compared the risk of thrombosis between bare-metal and drug-eluting stents. For this network meta-analysis, randomised controlled trials comparing different drug-eluting stents or drug-eluting with bare-metal stents currently approved in the USA were identified through Medline, Embase, Cochrane databases, and proceedings of international meetings. Information about study design, inclusion and exclusion criteria, sample characteristics, and clinical outcomes was extracted. 49 trials including 50,844 patients randomly assigned to treatment groups were analysed. 1-year definite stent thrombosis was significantly lower with cobalt-chromium everolimus eluting stents (CoCr-EES) than with bare-metal stents (odds ratio [OR] 0·23, 95% CI 0·13-0·41). The significant difference in stent thrombosis between CoCr-EES and bare-metal stents was evident as early as 30 days (OR 0·21, 95% CI 0·11-0·42) and was also significant between 31 days and 1 year (OR 0·27, 95% CI 0·08-0·74). CoCr-EES were also associated with significantly lower rates of 1-year definite stent thrombosis compared with paclitaxel-eluting stents (OR 0·28, 95% CI 0·16-0·48), permanent polymer-based sirolimus-eluting stents (OR 0·41, 95% CI 0·24-0·70), phosphorylcholine-based zotarolimus-eluting stents (OR 0·21, 95% CI 0·10-0·44), and Resolute zotarolimus-eluting stents (OR 0·14, 95% CI 0·03-0·47). At 2-year follow-up, CoCr-EES were still associated with significantly lower rates of definite stent thrombosis than were bare-metal (OR 0·35, 95% CI 0·17-0·69) and paclitaxel-eluting stents (OR 0·34, 95% CI 0·19-0·62). No other drug-eluting stent had lower definite thrombosis rates compared with bare-metal stents at 2-year follow-up. In randomised studies completed to date, CoCr-EES has the lowest rate of stent thrombosis within 2 years of implantation. The finding that CoCr-EES also reduced stent thrombosis compared with bare-metal stents, if confirmed in future randomised trials, represents a paradigm shift. The Cardiovascular Research Foundation. Copyright © 2012 Elsevier Ltd. All rights reserved.

  2. Modeling water infiltration and pesticides transport in unsaturated zone of a sedimentary aquifer

    NASA Astrophysics Data System (ADS)

    Sidoli, Pauline; Angulo-Jaramillo, Rafael; Baran, Nicole; Lassabatère, Laurent

    2015-04-01

    Groundwater quality monitoring has become an important environmental, economic and community issue since increasing needs drinking water at the same time with high anthropic pressure on aquifers. Leaching of various contaminants as pesticide into the groundwater is closely bound to water infiltration in the unsaturated zone which whom solute transport can occur. Knowledge's about mechanisms involved in the transfer of pesticides in the deep unsaturated zone are lacking today. This study aims to evaluate and to model leaching of pesticides and metabolites in the unsaturated zone, very heterogeneous, of a fluvio-glacial aquifer, in the South-East of France, where contamination of groundwater resources by pesticides is frequently observed as a consequence of intensive agricultural activities. Water flow and pesticide transport were evaluated from column tests under unsaturated conditions and from adsorption batch experiments onto the predominant lithofacies collected, composed of a mixture of sand and gravel. A maize herbicide, S-metolachlor, applied on the study site and worldwide and its two major degradation products (metolachlor ethanesulfonic acid and metolachlor oxanilic acid) were studied here. A conservative tracer, bromide ion, was used to determine water dispersive parameters of porous media. Elution curves were obtained from pesticide concentrations analyzed by an ultra-performance liquid chromatography system interfaced to a triple quadrupole mass spectrometer and from bromide concentrations measured by ionic chromatography system. Experimental data were implemented into Hydrus to model flow and solute transfer through a 1D profile in the vadose zone. Nonequilibrium solute transport model based on dual-porosity model with mobile and immobile water is fitting correctly elution curves. Water dispersive parameters show flow pattern realized in the mobile phase. Exchanges between mobile and immobile water are very limited. Because of low adsorptions onto fluvio-glacial deposits, retention of S-metolachlor and its ionic metabolites is low in column tests and high mobility was observed meaning these molecules are prone to reach groundwater.

  3. Leaching of FGD Byproducts Using a CSTX

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kairies, C.L.; Schroeder, K.T.; Cardone, C.R.

    2005-09-01

    Leaching studies of coal utilization byproducts (CUB) are often performed to determine the compatibility of the material in a particular end-use or disposal environment. Typically, these studies are conducted using either a batch or a fixed-bed column technique. Fixed-bed columns offer the advantage of a continuous flow of effluent that provides elution profiles with changing elution volume and pH. Unfortunately, clogs can form in fixed-bed leaching columns, either because of cementitious properties of the material itself, such as is seen for fluidized bed combustion (FBC) fly ash, or because of precipitate formation, such as can occur when a high-calcium ashmore » is subjected to sulfate-containing leachates. Also, very fine-grained materials, such as gypsum, do not provide sufficient permeability for study in a fixed-bed column. A continuous, stirred-tank extractor (CSTX) is being used as an alternative technique that can provide the elution profile of column leaching but without the low permeability problems. The CSTX has been successfully employed in the leaching of flue gas desulfurization products that would not be sufficiently permeable under traditional column leaching conditions. The results indicate that the leaching behavior depends on a number of factors, including (but not limited to) solubility and neutralization capacity of the mineral phases present, sorption properties of these phases, behavior of the solubilized material in the tank, and the type of species in solution. In addition, leaching to near-exhaustion of a wallboard produced from FGD gypsum has allowed the isolation of a highly adsorptive phase. This phase appears to be present in at least some FGD gypsums and accounts for the immobilization of trace metals such as arsenic, cobalt, lead, and mercury.« less

  4. Optimization of adenovirus 40 and 41 recovery from tap water using small disk filters.

    PubMed

    McMinn, Brian R

    2013-11-01

    Currently, the U.S. Environmental Protection Agency's Information Collection Rule (ICR) for the primary concentration of viruses from drinking and surface waters uses the 1MDS filter, but a more cost effective option, the NanoCeram® filter, has been shown to recover comparable levels of enterovirus and norovirus from both matrices. In order to achieve the highest viral recoveries, filtration methods require the identification of optimal concentration conditions that are unique for each virus type. This study evaluated the effectiveness of 1MDS and NanoCeram filters in recovering adenovirus (AdV) 40 and 41 from tap water, and optimized two secondary concentration procedures the celite and organic flocculation method. Adjustments in pH were made to both virus elution solutions and sample matrices to determine which resulted in higher virus recovery. Samples were analyzed by quantitative PCR (qPCR) and Most Probable Number (MPN) techniques and AdV recoveries were determined by comparing levels of virus in sample concentrates to that in the initial input. The recovery of adenovirus was highest for samples in unconditioned tap water (pH 8) using the 1MDS filter and celite for secondary concentration. Elution buffer containing 0.1% sodium polyphosphate at pH 10.0 was determined to be most effective overall for both AdV types. Under these conditions, the average recovery for AdV40 and 41 was 49% and 60%, respectively. By optimizing secondary elution steps, AdV recovery from tap water could be improved at least two-fold compared to the currently used methodology. Identification of the optimal concentration conditions for human AdV (HAdV) is important for timely and sensitive detection of these viruses from both surface and drinking waters. Published by Elsevier B.V.

  5. A case of Z/E-isomers elution order inversion caused by cosolvent percentage change in supercritical fluid chromatography.

    PubMed

    Pokrovskiy, Oleg I; Ustinovich, Konstantin B; Usovich, Oleg I; Parenago, Olga O; Lunin, Valeriy V; Ovchinnikov, Denis V; Kosyakov, Dmitry S

    2017-01-06

    A case of elution order inversion caused by cosolvent percentage change in supercritical fluid chromatography was observed and investigated in some detail. Z- and E-isomers of phenylisobutylketone oxime experience an elution order reversal on most columns if the mobile phase consists of CO 2 and alcohol. At lower percentages of alcohol Z-oxime is retained less, somewhere at 2-5% coelution occurs and at larger cosolvent volume elution order reverses - Z-oxime is eluted later than E-oxime. We suppose inversion with CO 2 -ROH phases happens due to a shift in balance between two main interactions governing retention. At low ROH percentages stationary phase surface is only slightly covered by ROH molecules so oximes primarily interact with adsorption sites via hydrogen bond formation. Due to intramolecular sterical hindrance Z-oxime is less able to form hydrogen bonds and consequently is eluted first. At higher percentages alcohols occupy most of strong hydrogen bonding sites on silica surface thus leaving non-specific electrostatic interactions predominantly responsible for Z/E selectivity. Z-oxime has a much larger dipole moment than E-oxime and at these conditions it is eluted later. Additional experimental data with CO 2 -CH 3 CN, hexane-iPrOH and CHF 3 -ROH mobile phases supporting this explanation are presented. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Modeling of salt and pH gradient elution in ion-exchange chromatography.

    PubMed

    Schmidt, Michael; Hafner, Mathias; Frech, Christian

    2014-01-01

    The separation of proteins by internally and externally generated pH gradients in chromatofocusing on ion-exchange columns is a well-established analytical method with a large number of applications. In this work, a stoichiometric displacement model was used to describe the retention behavior of lysozyme on SP Sepharose FF and a monoclonal antibody on Fractogel SO3 (S) in linear salt and pH gradient elution. The pH dependence of the binding charge B in the linear gradient elution model is introduced using a protein net charge model, while the pH dependence of the equilibrium constant is based on a thermodynamic approach. The model parameter and pH dependences are calculated from linear salt gradient elutions at different pH values as well as from linear pH gradient elutions at different fixed salt concentrations. The application of the model for the well-characterized protein lysozyme resulted in almost identical model parameters based on either linear salt or pH gradient elution data. For the antibody, only the approach based on linear pH gradients is feasible because of the limited pH range useful for salt gradient elution. The application of the model for the separation of an acid variant of the antibody from the major monomeric form is discussed. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. A new polymer-free drug-eluting stent with nanocarriers eluting sirolimus from stent-plus-balloon compared with bare-metal stent and with biolimus A9 eluting stent in porcine coronary arteries.

    PubMed

    Takimura, Celso K; Galon, Micheli Z; Gutierrez, Paulo S; Sojitra, Prakash; Vyas, Ashwin; Doshi, Manish; Lemos, Pedro A

    2015-04-01

    Permanent polymers in first generation drug-eluting stent (DES) have been imputed to be a possible cause of persistent inflammation, remodeling, malapposition and late stent thrombosis. We aim to describe the in vivo experimental result of a new polymer-free DES eluting sirolimus from stent-plus-balloon (Focus np stent, Envision Scientific) compared with a bare-metal stent (BMS) (Amazonia CroCo, Minvasys) and with a biolimus A9 eluting stent (Biomatrix, Biosensors). In 10 juvenile pigs, 23 coronary stents were implanted in the coronary arteries (8 Amazonia CroCo, 8 Focus np, and 7 Biomatrix). At 28-day follow-up, optical coherence tomography (OCT) and histology were used to evaluate neointimal hyperplasia and healing response. According to OCT analysis, Focus np stents had a greater lumen area and less neointimal hyperplasia response than BMS and Biomatrix had. Histomorphometry results showed less neointimal hyperplasia in Focus np than in BMS. Histology showed a higher fibrin deposition in Biomatrix stent compared to Focus np and BMS. The new polymer-free DES with sirolimus eluted from stent-plus-balloon demonstrated safety and reduced neointimal proliferation compared with the BMS and Biomatrix stents at 28-day follow-up in this porcine coronary model. This new polymer-free DES is promising and warrants further clinical studies.

  8. A new large-scale manufacturing platform for complex biopharmaceuticals.

    PubMed

    Vogel, Jens H; Nguyen, Huong; Giovannini, Roberto; Ignowski, Jolene; Garger, Steve; Salgotra, Anil; Tom, Jennifer

    2012-12-01

    Complex biopharmaceuticals, such as recombinant blood coagulation factors, are addressing critical medical needs and represent a growing multibillion-dollar market. For commercial manufacturing of such, sometimes inherently unstable, molecules it is important to minimize product residence time in non-ideal milieu in order to obtain acceptable yields and consistently high product quality. Continuous perfusion cell culture allows minimization of residence time in the bioreactor, but also brings unique challenges in product recovery, which requires innovative solutions. In order to maximize yield, process efficiency, facility and equipment utilization, we have developed, scaled-up and successfully implemented a new integrated manufacturing platform in commercial scale. This platform consists of a (semi-)continuous cell separation process based on a disposable flow path and integrated with the upstream perfusion operation, followed by membrane chromatography on large-scale adsorber capsules in rapid cycling mode. Implementation of the platform at commercial scale for a new product candidate led to a yield improvement of 40% compared to the conventional process technology, while product quality has been shown to be more consistently high. Over 1,000,000 L of cell culture harvest have been processed with 100% success rate to date, demonstrating the robustness of the new platform process in GMP manufacturing. While membrane chromatography is well established for polishing in flow-through mode, this is its first commercial-scale application for bind/elute chromatography in the biopharmaceutical industry and demonstrates its potential in particular for manufacturing of potent, low-dose biopharmaceuticals. Copyright © 2012 Wiley Periodicals, Inc.

  9. Conservation of hearing and protection of auditory hair cells against trauma-induced losses by local dexamethasone therapy: molecular and genetic mechanisms.

    PubMed

    Van De Water, Thomas R; Abi Hachem, Ralph N; Dinh, Christine T; Bas, Esperanza; Haake, Scott M; Hoosien, Gia; Vivero, Richard; Chan, Sherry; He, Jao; Eshraghi, Adrien A; Angeli, Simon I; Telischi, Fred F; Balkany, Thomas J

    2010-06-01

    Dexamethasone (DXM) protects hearing against trauma-induced loss. in vivo: A guinea pig model of electrode induced trauma (EIT)-induced hearing loss was used to locally deliver dexamethasone. In vitro: TNF-α-challenged organ of Corti explants treated with DXM or polymer-eluted DXM +/- PI3K/Akt/PkB/NFkB inhibitors were used for hair cells count and gene expression studies. in vivo: local DXM treatment of EIT-animals prevents trauma-induced loss of ABR thresholds that occurs in EIT-animals and EIT-animals treated with the carrier solution (i.e., AP), and prevented loss of auditory hair cells. In vitro: DXM and polymer-eluted DXM were equally effective in protecting hair cells from ototoxic levels of TNF-α Inhibitor treated explants demonstrated that DXM treatment requires both Akt/PKB and NFkB signalling for otoprotection. DXM treatment of explants showed up regulation of anti-apoptosis related genes (i.e., Bcl-2, Bcl-xl) and down regulation of pro-apoptosis related genes (i.e., Bax, TNFR-1). DXM exert its otoprotective action by activation of cell signal molecules (e.g., NFkB) that alter the expression of anti- and pro-apoptosis genes.

  10. Stability of human interferon-beta 1: oligomeric human interferon-beta 1 is inactive but is reactivated by monomerization.

    PubMed

    Utsumi, J; Yamazaki, S; Kawaguchi, K; Kimura, S; Shimizu, H

    1989-10-05

    Human interferon-beta 1 is extremely stable is a low ionic strength solution of pH 2 such as 10 mM HCl at 37 degrees C. However, the presence of 0.15 M NaCl led to a remarkable loss of antiviral activity. The molecular-sieve high-performance liquid chromatography revealed that, whereas completely active human interferon-beta 1 eluted as a 25 kDa species (monomeric form), the inactivated preparation eluted primarily as a 90 kDa species (oligomeric form). The specific activity (units per mg protein) of the oligomeric form was approx. 10% of that of the monomeric form. This observation shows that oligomeric human interferon-beta 1 is apparently in an inactive form. When the oligomeric eluate was resolved by polyacrylamide gel containing sodium dodecyl sulphate (SDS), it appeared to be monomeric under non-reducing conditions. Monomerization of the oligomeric human interferon-beta 1 by treatment with 1% SDS, fully regenerated its antiviral activity. These results suggest that the inactivation of the human interferon-beta 1 preparation was caused by its oligomerization via hydrophobic interactions without the formation of intermolecular disulphide bonds. These oligomers can be dissociated by SDS to restore biological activity.

  11. Analysis of trace dicyandiamide in stream water using solid phase extraction and liquid chromatography UV spectrometry.

    PubMed

    Qiu, Huidong; Sun, Dongdi; Gunatilake, Sameera R; She, Jinyan; Mlsna, Todd E

    2015-09-01

    An improved method for trace level quantification of dicyandiamide in stream water has been developed. This method includes sample pretreatment using solid phase extraction. The extraction procedure (including loading, washing, and eluting) used a flow rate of 1.0mL/min, and dicyandiamide was eluted with 20mL of a methanol/acetonitrile mixture (V/V=2:3), followed by pre-concentration using nitrogen evaporation and analysis with high performance liquid chromatography-ultraviolet spectroscopy (HPLC-UV). Sample extraction was carried out using a Waters Sep-Pak AC-2 Cartridge (with activated carbon). Separation was achieved on a ZIC(®)-Hydrophilic Interaction Liquid Chromatography (ZIC-HILIC) (50mm×2.1mm, 3.5μm) chromatography column and quantification was accomplished based on UV absorbance. A reliable linear relationship was obtained for the calibration curve using standard solutions (R(2)>0.999). Recoveries for dicyandiamide ranged from 84.6% to 96.8%, and the relative standard deviations (RSDs, n=3) were below 6.1% with a detection limit of 5.0ng/mL for stream water samples. Copyright © 2015. Published by Elsevier B.V.

  12. Preparative Separation and Purification of the Total Flavonoids in Scorzonera austriaca with Macroporous Resins.

    PubMed

    Xie, Yang; Guo, Qiu-Shi; Wang, Guang-Shu

    2016-06-13

    The use of macroporous resins for the separation and purification of total flavonoids to obtain high-purity total flavonoids from Scorzonera austriaca was studied. The optimal conditions for separation and purification of total flavonoids in S. austriaca with macroporous resins were as follows: D4020 resin columns were loaded with crude flavonoid extract solution, and after reaching adsorptive saturation, the columns were eluted successively with 5 bed volumes (BV) of water, 5 BV of 5% (v/v) aqueous ethanol and 5 BV of 30% (v/v) aqueous ethanol at an elute flow rate of 2 BV·h(-1). Total flavonoids were obtained from the 30% aqueous ethanol eluate by vacuum distillation recovery. The content of flavonoid compounds in the total flavonoids was 93.5%, which represents an improvement by about 150%. In addition, five flavonoid compounds in the product were identified as 2″-O-β-d-xylopyranosyl isoorientin, 6-C-α-l-arabipyranosyl orientin, orientin, isoorientin and vitexin by LC-ESI-MS analysis and internal standard methods. The results in this study could represent a method for the large-scale production of total flavonoids from S. austriaca.

  13. Evaluation of immobilized metal-ion affinity chromatography (IMAC) as a technique for IgG(1) monoclonal antibodies purification: the effect of chelating ligand and support.

    PubMed

    Bresolin, I T L; Borsoi-Ribeiro, M; Tamashiro, W M S C; Augusto, E F P; Vijayalakshmi, M A; Bueno, S M A

    2010-04-01

    Monoclonal antibodies (MAbs) have been used for therapies and some analytical procedures as highly purified molecules. Many techniques have been applied and studied, focusing on monoclonal antibodies purification. In this study, an immobilized metal affinity chromatography membrane was developed and evaluated for the purification of anti-TNP IgG(1) mouse MAbs from cell culture supernatant after precipitation with a 50% saturated ammonium sulfate solution. The chelating ligands iminodiacetic acid, carboxymethylated aspartic acid (CM-Asp), nitrilotriacetic acid, and tris (carboxymethyl) ethylenediamine in agarose gels with immobilized Ni(II) and Zn(II) ions were compared for the adsorption and desorption of MAbs. The most promising chelating ligand--CM-Asp--was then coupled to poly(ethylene vinyl alcohol) (PEVA) hollow fiber membranes. According to SDS-PAGE and ELISA analyses, a higher selectivity and a purification factor of 85.9 (fraction eluted at 500 mM Tris) were obtained for IgG(1) using PEVA-CM-Asp-Zn(II). The anti-TNP MAb could be eluted under mild pH conditions causing no loss of antigen binding capacity.

  14. A Microwave Flow Detector for Gradient Elution Liquid Chromatography.

    PubMed

    Ye, Duye; Wang, Weizheng; Moline, David; Islam, Md Saiful; Chen, Feng; Wang, Pingshan

    2017-10-17

    This study presents a microwave flow detector technique for liquid chromatography (LC) application. The detector is based on a tunable microwave interferometer (MIM) with a vector network analyzer (VNA) for signal measurement and a computer for system control. A microstrip-line-based 0.3 μL flow cell is built and incorporated into the MIM. With syringe pump injection, the detector is evaluated by measuring a few common chemicals in DI water at multiple frequencies from 0.98 to 7.09 GHz. Less than 30 ng minimum detectable quantity (MDQ) is demonstrated. An algorithm is provided and used to obtain sample dielectric permittivity at each frequency point. When connected to a commercial HPLC system and injected with a 10 μL aliquot of 10 000 ppm caffeine DI-water solution, the microwave detector yields a signal-to-noise ratio (SNR) up to 10 under isocratic and gradient elution operations. The maximum sampling rate is 20 Hz. The measurements show that MIM tuning, aided by a digital tunable attenuator (DTA), can automatically adjust MIM operation to retain detector sensitivity when mobile phase changes. Furthermore, the detector demonstrates a capability to quantify coeluted vitamin E succinate (VES) and vitamin D 3 (VD 3 ).

  15. [Separation/preconcentration of trace rare earth elements in Tricholoma giganteum by micro-column with nanometer A1203 and their determination by ICP-AES].

    PubMed

    Liu, Hong-gao; Wang, Yuan-zhong

    2010-01-01

    Using a micro-column packed with immobilized 1-phenyl-3-methyl-4-bonzoil-5-pyrazone(PMBP) on nanometer Al2O3 powder as the adsorption material, the adsorption and elution behaviors of rare earth ions (Sc3+, Y3+ and La3+) on the above material under dynamic conditions were studied with inductively coupled plasma-atomic emission spectrometry. The conditions for preconcentration of rare earth ions were optimized, and the results show that the studied ions can be adsorbed quantitatively on the above material at pH 4.5 and the analytes adsorbed on the column can be eluted with 0.5 mol x L(-1) HCl solution. The detection limits of the method for Sc, Y and La were 0.15, 0.18 and 0.34 microg x L(-1), respectively, and the relative standard deviations were 2.5%, 3.0% and 1.7%, respectively (n=12, c = 0.5 mg x L(-1)). The proposed method was applied to the determination of trace amount of Sc, Y and La in Tricholoma giganteum with satisfactory results.

  16. Comparison of everolimus- and paclitaxel-eluting stents in patients with acute and stable coronary syndromes: pooled results from the SPIRIT (A Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System) and COMPARE (A Trial of Everolimus-Eluting Stents and Paclitaxel-Eluting Stents for Coronary Revascularization in Daily Practice) Trials.

    PubMed

    Planer, David; Smits, Pieter C; Kereiakes, Dean J; Kedhi, Elvin; Fahy, Martin; Xu, Ke; Serruys, Patrick W; Stone, Gregg W

    2011-10-01

    This study sought to compare the clinical outcomes of everolimus-eluting stents (EES) versus paclitaxel-eluting stents (PES) in patients with acute coronary syndromes (ACS) and stable coronary artery disease (CAD). Although randomized trials have shown superiority of EES to PES, the safety and efficacy of EES in ACS is unknown. We performed a patient-level pooled analysis from the prospective, randomized SPIRIT (Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System) II, III, IV, and COMPARE (A Trial of Everolimus-Eluting Stents and Paclitaxel-Eluting Stents for Coronary Revascularization in Daily Practice) trials in which 2,381 patients with ACS and 4,404 patients with stable CAD were randomized to EES or to PES. Kaplan-Meier estimates of death, myocardial infarction (MI), ischemia-driven target lesion revascularization, and stent thrombosis were assessed at 2 years and stratified by clinical presentation (ACS vs. stable CAD). At 2 years, patients with ACS compared with stable CAD had higher rates of death (3.2% vs. 2.4%, hazard ratio [HR]: 1.37 [95% confidence interval (CI): 1.02 to 1.85], p = 0.04) and MI (4.9% vs. 3.4%, HR: 1.45 [95% CI: 1.14 to 1.85], p = 0.02). In patients with ACS, EES versus PES reduced the rate of death or MI (6.6% vs. 9.3%, HR: 0.70 [95% CI: 0.52 to 0.94], p = 0.02), stent thrombosis (0.7% vs. 2.9%, HR: 0.25 [95% CI: 0.12 to 0.52], p = 0.0002), and ischemia-driven target lesion revascularization (4.7% vs. 6.2%, HR: 0.69 [95% CI: 0.48 to 0.99], p = 0.04). In patients with stable CAD, EES reduced the rate of death or MI (4.5% vs. 7.1%, HR: 0.62 [95% CI: 0.48 to 0.80], p = 0.0002), stent thrombosis (0.7% vs. 1.8%, HR: 0.34 [95% CI: 0.19 to 0.62], p = 0.0002), and ischemia-driven target lesion revascularization (3.9% vs. 6.9%, HR: 0.55 [95% CI: 0.42 to 0.73], p < 0.0001). Treatment with EES versus PES provides enhanced safety and efficacy regardless of the acuity of the clinical syndrome being treated and appears to mitigate the increased risk of stent thrombosis associated with ACS. (A Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System in the Treatment of Patients With de Novo Native Coronary Artery Lesions [SPIRIT II]; NCT00180310; SPIRIT III: A Clinical Evaluation of the Investigational Device XIENCE V Everolimus Eluting Coronary Stent System [EECSS] in the Treatment of Subjects With de Novo Native Coronary Artery Lesions [SPIRIT III]; NCT00180479; SPIRIT IV Clinical Trial: Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System in the Treatment of Subjects With de Novo Native Coronary Artery Lesions [SPIRIT IV]; NCT00307047; A Trial of Everolimus-Eluting Stents and Paclitaxel-Eluting Stents for Coronary Revascularization in Daily Practice: the COMPARE Trial [COMPARE]; NCT01016041). Copyright © 2011 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  17. Detachable strong cation exchange monolith, integrated with capillary zone electrophoresis and coupled with pH gradient elution, produces improved sensitivity and numbers of peptide identifications during bottom-up analysis of complex proteomes.

    PubMed

    Zhang, Zhenbin; Yan, Xiaojing; Sun, Liangliang; Zhu, Guijie; Dovichi, Norman J

    2015-04-21

    A detachable sulfonate-silica hybrid strong cation-exchange monolith was synthesized in a fused silica capillary, and used for solid phase extraction with online pH gradient elution during capillary zone electrophoresis-tandem mass spectrometry (CZE-MS/MS) proteomic analysis. Tryptic digests were prepared in 50 mM formic acid and loaded onto the strong cation-exchange monolith. Fractions were eluted using a series of buffers with lower concentration but higher pH values than the 50 mM formic acid background electrolyte. This combination of elution and background electrolytes results in both sample stacking and formation of a dynamic pH junction and allows use of relatively large elution buffer volumes while maintaining reasonable peak efficiency and resolution. A series of five pH bumps were applied to elute E. coli tryptic peptides from the monolith, followed by analysis using CZE coupled to an LTQ-Orbitrap Velos mass spectrometer; 799 protein groups and 3381 peptides were identified from 50 ng of the digest in a 2.5 h analysis, which approaches the identification rate for this organism that was obtained with an Orbitrap Fusion. We attribute the improved numbers of peptide and protein identifications to the efficient fractionation by the online pH gradient elution, which decreased the complexity of the sample in each elution step and improved the signal intensity of low abundance peptides. We also performed a comparative analysis using a nanoACQUITY UltraPerformance LCH system. Similar numbers of protein and peptide identifications were produced by the two methods. Protein identifications showed significant overlap between the two methods, whereas peptide identifications were complementary.

  18. Multiplexed electrokinetic sample fractionation, preconcentration and elution for proteomics.

    PubMed

    Hua, Yujuan; Jemere, Abebaw B; Dragoljic, Jelena; Harrison, D Jed

    2013-07-07

    Both 6 and 8-channel integrated microfluidic sample pretreatment devices capable of performing "in space" sample fractionation, collection, preconcentration and elution of captured analytes via sheath flow assisted electrokinetic pumping are described. Coatings and monolithic polymer beds were developed for the glass devices to provide cationic surface charge and anodal electroosmotic flow for delivery to an electrospray emitter tip. A mixed cationic ([2-(methacryloyloxy)ethyl] trimethylammonium chloride) (META) and hydrophobic butyl methacrylate-based monolithic porous polymer, photopolymerized in the 6- or 8-fractionation channels, was used to capture and preconcentrate samples. A 0.45 wt% META loaded bed generated comparable anodic electroosmotic flow to the cationic polymer PolyE-323 coated channel segments in the device. The balanced electroosmotic flow allowed stable electrokinetic sheath flow to prevent cross contamination of separated protein fractions, while reducing protein/peptide adsorption on the channel walls. Sequential elution of analytes trapped in the SPE beds revealed that the monolithic columns could be efficiently used to provide sheath flow during elution of analytes, as demonstrated for neutral carboxy SNARF (residual signal, 0.08% RSD, n = 40) and charged fluorescein (residual signal, 2.5% n = 40). Elution from monolithic columns showed reproducible performance with peak area reproducibility of ~8% (n = 6 columns) in a single sequential elution and the run-to-run reproducibility was 2.4-6.7% RSD (n = 4) for elution from the same bed. The demonstrated ability of this device design and operation to elute from multiple fractionation beds into a single exit channel for sample analysis by fluorescence or electrospray mass spectrometry is a crucial component of an integrated fractionation and assay system for proteomics.

  19. Effectiveness and safety of drug-eluting stents in Ontario.

    PubMed

    Tu, Jack V; Bowen, James; Chiu, Maria; Ko, Dennis T; Austin, Peter C; He, Yaohua; Hopkins, Robert; Tarride, Jean-Eric; Blackhouse, Gord; Lazzam, Charles; Cohen, Eric A; Goeree, Ron

    2007-10-04

    The placement of drug-eluting stents decreases the frequency of repeat revascularization procedures in patients undergoing percutaneous coronary intervention (PCI) in randomized clinical trials. However, there is uncertainty about the effectiveness of drug-eluting stents, and increasing concern about their safety, in routine clinical practice. From the Cardiac Care Network of Ontario's population-based clinical registry of all patients undergoing PCI in Ontario, Canada, we identified a well-balanced cohort of 3751 pairs of patients, matched on the basis of propensity score, who received either bare-metal stents alone or drug-eluting stents alone during an index PCI procedure between December 1, 2003, and March 31, 2005. The primary outcomes of the study were the rates of target-vessel revascularization, myocardial infarction, and death. The 2-year rate of target-vessel revascularization was significantly lower among patients who received drug-eluting stents than among those who received bare-metal stents (7.4% vs. 10.7%, P<0.001). Drug-eluting stents were associated with significant reductions in the rate of target-vessel revascularization among patients with two or three risk factors for restenosis (i.e., presence of diabetes, small vessels [<3 mm in diameter], and long lesions [> or =20 mm]) but not among lower-risk patients. The 3-year mortality rate was significantly higher in the bare-metal-stent group than in the drug-eluting-stent group (7.8% vs. 5.5%, P<0.001), whereas the 2-year rate of myocardial infarction was similar in the two groups (5.2% and 5.7%, respectively; P=0.95). Drug-eluting stents are effective in reducing the need for target-vessel revascularization in patients at highest risk for restenosis, without a significantly increased rate of death or myocardial infarction. Copyright 2007 Massachusetts Medical Society.

  20. CONCENTRATION AND PROCESSING OF WATERBORNE VIRUSES BY POSITIVE CHARGE 1MDS CARTRIDGE FILTERS AND ORGANIC FLOCCULATION

    EPA Science Inventory

    This chapter describes the most widely used virus adsorption-elution (VIRADEL) method for recovering human enteric viruses from water matrices (Fout et al., 1996). The method takes advantage of postively charged cartridge filters to concentrate viruses from water. The major adv...

  1. Electrodialytic in-line preconcentration for ionic solute analysis.

    PubMed

    Ohira, Shin-Ichi; Yamasaki, Takayuki; Koda, Takumi; Kodama, Yuko; Toda, Kei

    2018-04-01

    Preconcentration is an effective way to improve analytical sensitivity. Many types of methods are used for enrichment of ionic solute analytes. However, current methods are batchwise and include procedures such as trapping and elution. In this manuscript, we propose in-line electrodialytic enrichment of ionic solutes. The method can enrich ionic solutes within seconds by quantitative transfer of analytes from the sample solution to the acceptor solution under an electric field. Because of quantitative ion transfer, the enrichment factor (the ratio of the concentration in the sample and to that in the obtained acceptor solution) only depends on the flow rate ratio of the sample solution to the acceptor solution. The ratios of the concentrations and flow rates are equal for ratios up to 70, 20, and 70 for the tested ionic solutes of inorganic cations, inorganic anions, and heavy metal ions, respectively. The sensitivity of ionic solute determinations is also improved based on the enrichment factor. The method can also simultaneously achieve matrix isolation and enrichment. The method was successively applied to determine the concentrations of trace amounts of chloroacetic acids in tap water. The regulated concentration levels cannot be determined by conventional high-performance liquid chromatography with ultraviolet detection (HPLC-UV) without enrichment. However, enrichment with the present method is effective for determination of tap water quality by improving the limits of detection of HPLC-UV. The standard addition test with real tap water samples shows good recoveries (94.9-109.6%). Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Effect of Nanoparticle Surface on the HPLC Elution Profile of Liposomal Nanoparticles.

    PubMed

    Itoh, Naoki; Yamamoto, Eiichi; Santa, Tomofumi; Funatsu, Takashi; Kato, Masaru

    2016-06-01

    Nanoparticles have been used in diverse areas, and even broader applications are expected in the future. Since surface modification can influence the configuration and toxicity of nanoparticles, a rapid screening method is important to ensure nanoparticle quality. We examined the effect of the nanoparticle surface morphology on the HPLC elution profile using two types of 100-nm liposomal nanoparticles (AmBisome(Ⓡ) and DOXIL(Ⓡ)). These 100-nm-sized nanoparticles eluted before the holdup time (about 4 min), even when a column packed with particles with a relatively large pore size (30 nm) was used. The elution time of the nanoparticles increased with pegylation of the nanoparticles and protein adsorption to the nanoparticles; however, the nanoparticles still eluted before the holdup time. The results of this study indicate that HPLC is a suitable tool for rapid evaluation of the surface of liposomal nanoparticles.

  3. Alendronate-Eluting Biphasic Calcium Phosphate (BCP) Scaffolds Stimulate Osteogenic Differentiation

    PubMed Central

    Kim, Sung Eun; Lee, Deok-Won; Kang, Eun Young; Jeong, Won Jae; Lee, Boram; Jeong, Myeong Seon; Kim, Hak Jun; Park, Kyeongsoon; Song, Hae-Ryong

    2015-01-01

    Biphasic calcium phosphate (BCP) scaffolds have been widely used in orthopedic and dental fields as osteoconductive bone substitutes. However, BCP scaffolds are not satisfactory for the stimulation of osteogenic differentiation and maturation. To enhance osteogenic differentiation, we prepared alendronate- (ALN-) eluting BCP scaffolds. The coating of ALN on BCP scaffolds was confirmed by scanning electron microscopy (FE-SEM), energy-dispersive X-ray spectroscopy (EDS), and attenuated total reflectance-Fourier transform infrared spectroscopy (ATR-FTIR). An in vitro release study showed that release of ALN from ALN-eluting BCP scaffolds was sustained for up to 28 days. In vitro results revealed that MG-63 cells grown on ALN-eluting BCP scaffolds exhibited increased ALP activity and calcium deposition and upregulated gene expression of Runx2, ALP, OCN, and OPN compared with the BCP scaffold alone. Therefore, this study suggests that ALN-eluting BCP scaffolds have the potential to effectively stimulate osteogenic differentiation. PMID:26221587

  4. The best practice for preparation of samples from FTA®cards for diagnosis of blood borne infections using African trypanosomes as a model system

    PubMed Central

    2011-01-01

    Background Diagnosis of blood borne infectious diseases relies primarily on the detection of the causative agent in the blood sample. Molecular techniques offer sensitive and specific tools for this although considerable difficulties exist when using these approaches in the field environment. In large scale epidemiological studies, FTA®cards are becoming increasingly popular for the rapid collection and archiving of a large number of samples. However, there are some difficulties in the downstream processing of these cards which is essential for the accurate diagnosis of infection. Here we describe recommendations for the best practice approach for sample processing from FTA®cards for the molecular diagnosis of trypanosomiasis using PCR. Results A comparison of five techniques was made. Detection from directly applied whole blood was less sensitive (35.6%) than whole blood which was subsequently eluted from the cards using Chelex®100 (56.4%). Better apparent sensitivity was achieved when blood was lysed prior to application on the FTA cards (73.3%) although this was not significant. This did not improve with subsequent elution using Chelex®100 (73.3%) and was not significantly different from direct DNA extraction from blood in the field (68.3%). Conclusions Based on these results, the degree of effort required for each of these techniques and the difficulty of DNA extraction under field conditions, we recommend that blood is transferred onto FTA cards whole followed by elution in Chelex®100 as the best approach. PMID:21548975

  5. Coupling of ultrasound-assisted extraction and expanded bed adsorption for simplified medicinal plant processing and its theoretical model: extraction and enrichment of ginsenosides from Radix Ginseng as a case study.

    PubMed

    Mi, Jianing; Zhang, Min; Zhang, Hongyang; Wang, Yuerong; Wu, Shikun; Hu, Ping

    2013-02-01

    A high-efficient and environmental-friendly method for the preparation of ginsenosides from Radix Ginseng using the method of coupling of ultrasound-assisted extraction with expanded bed adsorption is described. Based on the optimal extraction conditions screened by surface response methodology, ginsenosides were extracted and adsorbed, then eluted by the two-step elution protocol. The comparison results between the coupling of ultrasound-assisted extraction with expanded bed adsorption method and conventional method showed that the former was better than the latter in both process efficiency and greenness. The process efficiency and energy efficiency of the coupling of ultrasound-assisted extraction with expanded bed adsorption method rapidly increased by 1.4-fold and 18.5-fold of the conventional method, while the environmental cost and CO(2) emission of the conventional method were 12.9-fold and 17.0-fold of the new method. Furthermore, the theoretical model for the extraction of targets was derived. The results revealed that the theoretical model suitably described the process of preparing ginsenosides by the coupling of ultrasound-assisted extraction with expanded bed adsorption system. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Stability-indicating LC assay for butenafine hydrochloride in creams using an experimental design for robustness evaluation and photodegradation kinetics study.

    PubMed

    Barth, Aline Bergesch; de Oliveira, Gabriela Bolfe; Malesuik, Marcelo Donadel; Paim, Clésio Soldatelli; Volpato, Nadia Maria

    2011-08-01

    A stability-indicating liquid chromatography method for the determination of the antifungal agent butenafine hydrochloride (BTF) in a cream was developed and validated using the Plackett-Burman experimental design for robustness evaluation. Also, the drug photodegradation kinetics was determined. The analytical column was operated with acetonitrile, methanol and a solution of triethylamine 0.3% adjusted to pH 4.0 (6:3:1) at a flow rate of 1 mL/min and detection at 283 nm. BTF extraction from the cream was done with n-butyl alcohol and methanol in ultrasonic bath. The performed degradation conditions were: acid and basic media with HCl 1M and NaOH 1M, respectively, oxidation with H(2)O(2) 10%, and the exposure to UV-C light. No interference in the BTF elution was verified. Linearity was assessed (r(2) = 0.9999) and ANOVA showed non-significative linearity deviation (p > 0.05). Adequate results were obtained for repeatability, intra-day precision, and accuracy. Critical factors were selected to examine the method robustness with the two-level Plackett-Burman experimental design and no significant factors were detected (p > 0.05). The BTF photodegradation kinetics was determined for the standard and for the cream, both in methanolic solution, under UV light at 254 nm. The degradation process can be described by first-order kinetics in both cases.

  7. Drug-eluting stents and acute myocardial infarction: A lethal combination or friends?

    PubMed Central

    Otsuki, Shuji; Sabaté, Manel

    2014-01-01

    Primary percutaneous coronary intervention is the preferred reperfusion strategy for patients presenting with ST-segment elevation myocardial infarction (STEMI). First generation drug-eluting stents (DES), (sirolimus drug-eluting stents and paclitaxel drug-eluting stents), reduce the risk of restenosis and target vessel revascularization compared to bare metal stents. However, stent thrombosis emerged as a major safety concern with first generation DES. In response to these safety issues, second generation DES were developed with different drugs, improved stent platforms and more biocompatible durable or bioabsorbable polymeric coating. This article presents an overview of safety and efficacy of the first and second generation DES in STEMI. PMID:25276295

  8. Modelling Simple Experimental Platform for In Vitro Study of Drug Elution from Drug Eluting Stents (DES)

    NASA Astrophysics Data System (ADS)

    Kalachev, L. V.

    2016-06-01

    We present a simple model of experimental setup for in vitro study of drug release from drug eluting stents and drug propagation in artificial tissue samples representing blood vessels. The model is further reduced using the assumption on vastly different characteristic diffusion times in the stent coating and in the artificial tissue. The model is used to derive a relationship between the times at which the measurements have to be taken for two experimental platforms, with corresponding artificial tissue samples made of different materials with different drug diffusion coefficients, to properly compare the drug release characteristics of drug eluting stents.

  9. Studies on DNA damage: discordant responses of rate of DNA disentanglement (viscosimetrically evaluated) and alkaline elution rate, obtained for several compounds. Possible explanations of the discrepancies.

    PubMed

    Parodi, S; Balbi, C; Abelmoschi, M L; Pala, M; Russo, P; Santi, L

    1983-12-01

    Alkaline elution is a well-known method for detecting DNA damage. Recently we have developed a viscosimetric method that is even more sensitive than alkaline elution. Here we report that the two methods, although apparently both revealing alkaline DNA fragmentation, can give dramatically different results for a significant series of compounds. We suspect that alkaline elution might reveal not only DNA fragmentation but also the extent of disentanglement of chromatin structure, whereas this DNA disentanglement rate, when evaluated viscosimetrically , is more strictly correlated with the initiation of DNA unwinding.

  10. Drug eluting biliary stents to decrease stent failure rates: A review of the literature

    PubMed Central

    Shatzel, Joseph; Kim, Jisoo; Sampath, Kartik; Syed, Sharjeel; Saad, Jennifer; Hussain, Zilla H; Mody, Kabir; Pipas, J Marc; Gordon, Stuart; Gardner, Timothy; Rothstein, Richard I

    2016-01-01

    Biliary stenting is clinically effective in relieving both malignant and non-malignant obstructions. However, there are high failure rates associated with tumor ingrowth and epithelial overgrowth as well as internally from biofilm development and subsequent clogging. Within the last decade, the use of prophylactic drug eluting stents as a means to reduce stent failure has been investigated. In this review we provide an overview of the current research on drug eluting biliary stents. While there is limited human trial data regarding the clinical benefit of drug eluting biliary stents in preventing stent obstruction, recent research suggests promise regarding their safety and potential efficacy. PMID:26839648

  11. Tellurium Mobility Through Mine Environments

    NASA Astrophysics Data System (ADS)

    Dorsk, M.

    2015-12-01

    Tellurium is a rare metalloid that has received minimal research regarding environmental mobility. Observations of Tellurium mobility are mainly based on observations of related metalloids such as selenium and beryllium; yet little research has been done on specific Tellurium behavior. This laboratory work established the environmental controls that influence Tellurium mobility and chemical speciation in aqueous driven systems. Theoretical simulations show possible mobility of Te as Te(OH)3[+] at highly oxidizing and acidic conditions. Movement as TeO3[2-] under more basic conditions may also be possible in elevated Eh conditions. Mobility in reducing environments is theoretically not as likely. For a practical approach to investigate mobility conditions for Te, a site with known Tellurium content was chosen in Colorado. Composite samples were selected from the top, center and bottom of a tailings pile for elution experiments. These samples were disintegrated using a rock crusher and pulverized with an automated mortar and pestle. The material was then classified to 70 microns. A 10g sample split was digested in concentrated HNO3 and HF and analyzed by Atomic Absorption Spectroscopy to determine initial Te concentrations. Additional 10g splits from each location were subjected to elution in 100 mL of each of the following solutions; nitric acid to a pH of 1.0, sulfuric acid to a pH of 2.0, sodium hydroxide to a pH of 12, ammonium hydroxide to a pH of 10, a pine needle/soil tea from material within the vicinity of the collection site to a pH of 3.5 and lastly distilled water to serve as control with a pH of 7. Sulfuric acid was purposefully chosen to simulate acid mine drainage from the decomposition of pyrite within the mine tailings. Sample sub sets were also inundated with 10mL of a 3% hydrogen peroxide solution to induce oxidizing conditions. All collected eluates were then analyzed by atomic absorption spectroscopy (AAS) to measure Tellurium concentrations in each sample. The results provide a comparison of possible environmental Te mobility factors. While the process of bioavailability is not specifically addressed, preliminary data indicate a reference to perhaps assess impact to the local community and livestock relying on the San Miguel River, which is effected by run-off from the mine site.

  12. Temporal course of vascular healing and neoatherosclerosis after implantation of durable- or biodegradable-polymer drug-eluting stents.

    PubMed

    Guagliumi, Giulio; Shimamura, Kunihiro; Sirbu, Vasile; Garbo, Roberto; Boccuzzi, Giacomo; Vassileva, Angelina; Valsecchi, Orazio; Fiocca, Luigi; Canova, Paolo; Colombo, Francesco; Tensol Rodriguez Pereira, Gabriel; Nakamura, Daisuke; Attizzani, Guilherme F; Cereda, Alberto; Satogami, Keisuke; De Luca, Leonardo; Saia, Francesco; Capodanno, Davide

    2018-05-19

    Delayed healing and endothelial dysfunction may occur with drug-eluting stents (DES), promoting accelerated infiltration of lipids in the neointima and development of neoatherosclerosis (NA). Pathology data suggest durable polymer (DP) of DES to play a major role in this process. Whether biodegradable polymer (BP) may address these issues is uncertain. We compared in vivo vessel healing and NA of current generation BP- or DP-DES using serial optical coherence tomography (OCT) assessments. Ninety patients with multivessel coronary artery disease were randomized 1:1 to BP everolimus-eluting stents (EES, Synergy) or DP zotarolimus-eluting stents (ZES, Resolute Integrity). Co-primary endpoints were the maximum length of uncovered struts at 3 months (powered for non-inferiority) and the percentage of patients presenting with frames of NA at 18 months (powered for superiority) as measured by OCT. The maximum length of uncovered struts at 3 months was 10 ± 8 mm in the BP-EES group and 11 ± 7 mm in the DP-ZES group (mean difference -1 mm; upper 97.5% confidence interval +2 mm; P = 0.05 for non-inferiority; P = 0.45 for superiority). The percentage of patients presenting with frames of NA at 18 months was low and similar between BP-EES and DP-ZES groups (11.6% vs. 15.9%; P = 0.56). There was no stent thrombosis in both groups at 24 months. BP-EES and DP-ZES showed a similar healing response at 3 months and a low incidence of NA at 18 months. Biocompatible polymers, regardless of whether they are durable or biodegradable, may favourably impact the long-term vascular response to current-generation DES.

  13. A new polymer-free drug-eluting stent with nanocarriers eluting sirolimus from stent-plus-balloon compared with bare-metal stent and with biolimus A9 eluting stent in porcine coronary arteries

    PubMed Central

    Galon, Micheli Z.; Gutierrez, Paulo S.; Sojitra, Prakash; Vyas, Ashwin; Doshi, Manish; Lemos, Pedro A.

    2015-01-01

    Background Permanent polymers in first generation drug-eluting stent (DES) have been imputed to be a possible cause of persistent inflammation, remodeling, malapposition and late stent thrombosis. We aim to describe the in vivo experimental result of a new polymer-free DES eluting sirolimus from stent-plus-balloon (Focus np stent, Envision Scientific) compared with a bare-metal stent (BMS) (Amazonia CroCo, Minvasys) and with a biolimus A9 eluting stent (Biomatrix, Biosensors). Methods In 10 juvenile pigs, 23 coronary stents were implanted in the coronary arteries (8 Amazonia CroCo, 8 Focus np, and 7 Biomatrix). At 28-day follow-up, optical coherence tomography (OCT) and histology were used to evaluate neointimal hyperplasia and healing response. Results According to OCT analysis, Focus np stents had a greater lumen area and less neointimal hyperplasia response than BMS and Biomatrix had. Histomorphometry results showed less neointimal hyperplasia in Focus np than in BMS. Histology showed a higher fibrin deposition in Biomatrix stent compared to Focus np and BMS. Conclusions The new polymer-free DES with sirolimus eluted from stent-plus-balloon demonstrated safety and reduced neointimal proliferation compared with the BMS and Biomatrix stents at 28-day follow-up in this porcine coronary model. This new polymer-free DES is promising and warrants further clinical studies. PMID:25984451

  14. Protein A chromatography increases monoclonal antibody aggregation rate during subsequent low pH virus inactivation hold

    PubMed Central

    Mazzer, Alice R.; Perraud, Xavier; Halley, Jennifer; O’Hara, John; Bracewell, Daniel G.

    2015-01-01

    Protein A chromatography is a near-ubiquitous method of mAb capture in bioprocesses. The use of low pH buffer for elution from protein A is known to contribute to product aggregation. Yet, a more limited set of evidence suggests that low pH may not be the sole cause of aggregation in protein A chromatography, rather, other facets of the process may contribute significantly. This paper presents a well-defined method for investigating this problem. An IgG4 was incubated in elution buffer after protein A chromatography (typical of the viral inactivation hold) and the quantity of monomer in neutralised samples was determined by size exclusion chromatography; elution buffers of different pH values predetermined to induce aggregation of the IgG4 were used. Rate constants for monomer decay over time were determined by fitting exponential decay functions to the data. Similar experiments were implemented in the absence of a chromatography step, i.e. IgG4 aggregation at low pH. Rate constants for aggregation after protein A chromatography were considerably higher than those from low pH exposure alone; a distinct shift in aggregation rates was apparent across the pH range tested. PMID:26346187

  15. Elution of viruses by ionic and nonionic surfactants.

    PubMed Central

    Fujito, B T; Lytle, C D

    1996-01-01

    The ionic and nonionic surfactants sodium dodecyl sulfate and Triton X-100, respectively, eluted two viruses, phi X174 and PRD1, which were adsorbed to the ionic and nonionic binding membranes cationic polysulfone and nitrocellulose, respectively. Results indicated that complete elution was readily achieved only when combinations of surfactants and binding membranes were matched (i.e., ionic-ionic or nonionic-nonionic). PMID:8795240

  16. Biodegradable Polymer Biolimus-Eluting Stents Versus Durable Polymer Everolimus-Eluting Stents in Patients With Coronary Artery Disease: Final 5-Year Report From the COMPARE II Trial (Abluminal Biodegradable Polymer Biolimus-Eluting Stent Versus Durable Polymer Everolimus-Eluting Stent).

    PubMed

    Vlachojannis, Georgios J; Smits, Pieter C; Hofma, Sjoerd H; Togni, Mario; Vázquez, Nicolás; Valdés, Mariano; Voudris, Vassilis; Slagboom, Ton; Goy, Jean-Jaques; den Heijer, Peter; van der Ent, Martin

    2017-06-26

    This analysis investigates the 5-year outcomes of the biodegradable polymer biolimus-eluting stent (BP-BES) and durable polymer everolimus-eluting stent (DP-EES) in an all-comers population undergoing percutaneous coronary intervention. Recent 1- and 3-year results from randomized trials have indicated similar safety and efficacy outcomes of BP-BES and DP-EES. Whether benefits of the biodegradable polymer device arise over longer follow-up is unknown. Moreover, in-depth, prospective, long-term follow-up data on metallic drug-eluting stents with durable or biodegradable polymers are scarce. The COMPARE II trial (Abluminal Biodegradable Polymer Biolimus-Eluting Stent Versus Durable Polymer Everolimus-Eluting Stent) was a prospective, randomized, multicenter, all-comers trial in which 2,707 patients were randomly allocated (2:1) to BP-BES or DP-EES. The pre-specified endpoint at 5 years was major adverse cardiac events, a composite of cardiac death, nonfatal myocardial infarction, or target vessel revascularization. Five-year follow-up was available in 2,657 patients (98%). At 5 years, major adverse cardiac events occurred in 310 patients (17.3%) in the BP-BES group and 142 patients (15.6%) in the DP-EES group (p = 0.26). The rate of the combined safety endpoint all-cause death or myocardial infarction was 15.0% in the BP-BES group versus 14.8% in the DP-EES group (p = 0.90), whereas the efficacy measure target vessel revascularization was 10.6% versus 9.0% (p = 0.18), respectively. Interestingly, definite stent thrombosis rates did not differ between groups (1.5% for BP-BES vs. 0.9% for DP-EES; p = 0.17). The 5-year analysis comparing biodegradable polymer-coated BES and the durable polymer-coated EES confirms the initial early- and mid-term results regarding similar safety and efficacy outcomes in this all-comers percutaneous coronary intervention population. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  17. Cost-effectiveness of drug-eluting stents in patients at high or low risk of major cardiac events in the Basel Stent KostenEffektivitäts Trial (BASKET): an 18-month analysis.

    PubMed

    Brunner-La Rocca, Hans Peter; Kaiser, Christoph; Bernheim, Alain; Zellweger, Michael J; Jeger, Raban; Buser, Peter T; Osswald, Stefan; Pfisterer, Matthias

    2007-11-03

    Our aim was to determine whether drug-eluting stents are good value for money in long-term, everyday practice. We did an 18-month cost-effectiveness analysis of the Basel Stent KostenEffektivitäts Trial (BASKET), which randomised 826 patients 2:1 to drug-eluting stents (n=545) or to bare-metal stents (281). We used non-parametric bootstrap techniques to determine incremental cost-effectiveness ratios (ICERs) of drug-eluting versus bare-metal stents, to compare low-risk (> or =3.0 mm stents in native vessels; n=558, 68%) and high-risk patients (<3.0 mm stents/bypass graft stenting; n=268, 32%), and to do sensitivity analyses by altering costs and event rates in the whole study sample and in predefined subgroups. Quality-adjusted life-years (QALYs) were assessed by EQ-5D questionnaire (available in 703/826 patients). Overall costs were higher for patients with drug-eluting stents than in those with bare-metal stents (11,808 euros [SD 400] per patient with drug-eluting stents and 10,450 euros [592] per patient with bare-metal stents, mean difference 1358 euros [717], p<0.0001), due to higher stent costs. We calculated an ICER of 64,732 euros to prevent one major adverse cardiac event, and of 40,467 euros per QALY gained. Stent costs, number of events, and QALYs affected ICERs most, but unrealistic alterations would have been required to achieve acceptable cost-effectiveness. In low-risk patients, the probability of drug-eluting stents achieving an arbitrary ICER of 10,000 euros or less to prevent one major adverse cardiac event was 0.016; by contrast, it was 0.874 in high-risk patients. If used in all patients, drug-eluting stents are not good value for money, even if prices were substantially reduced. Drug-eluting stents are cost effective in patients needing small vessel or bypass graft stenting, but not in those who require large native vessel stenting.

  18. Involvement of COX-2 in nickel elution from a wire implanted subcutaneously in mice.

    PubMed

    Sato, Taiki; Kishimoto, Yu; Asakawa, Sanki; Mizuno, Natsumi; Hiratsuka, Masahiro; Hirasawa, Noriyasu

    2016-07-01

    Many types of medical alloys include nickel (Ni), and the elution of Ni ions from these materials causes toxicities and inflammation. We have previously reported that inflammation enhances Ni elution, although the molecular mechanisms underlying this effect remain unclear. In this study, we investigated how inflammatory responses enhanced Ni elution in a wire-implantation mouse model. Subcutaneous implantation of Ni wire induced the expression of cyclooxygenase-2 (COX-2) and microsomal prostaglandin E synthase-1 (mPGES-1) mRNA in the surrounding tissues. Immunostaining analysis showed that cells expressing COX-2 were mainly fibroblast-like cells 8h after implantation of a Ni wire, but were mainly infiltrated leukocytes at 24h. NiCl2 induced the expression of COX-2 mRNA in primary fibroblasts, neutrophils, RAW 264 cells, and THP-1 cells, indicating that Ni ions can induce COX-2 expression in various types of cells. The elution of Ni ions from the implanted Ni wire at 8h was reduced by dexamethasone (Dex), indomethacin (Ind), or celecoxib (Cel) treatment. Ni wire implantation induced an increase in mRNA levels for anaerobic glycolytic pathway components glucose transporter 1 (GLUT1), hexokinase 2 (HK2), lactate dehydrogenase A (LDHA), and monocarboxylate transporter 4 (MCT4); the expression of these genes was also inhibited by Dex, Ind, and Cel. In primary fibroblasts, the expression of these mRNAs and the production of lactate were induced by NiCl2 and further potentiated by PGE2. Furthermore, Ni wire-induced infiltration of inflammatory leukocytes was significantly reduced by Dex, Ind, or Cel. Depletion of neutrophils with a specific antibody caused reduction of both leukocyte infiltration and Ni elution. These results indicate that Ni ions eluted from wire induced COX-2 expression, which further promoted elution of Ni ions by increasing lactate production and leukocyte infiltration. Since COX inhibitors and Dex reduced the elution of Ni ions, these drugs may be useful for prevention of metal-related inflammation and allergy. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  19. [Serum pharmacochemistry of Qinbai Qingfei concentrated pellets based on UPLC-Q-TOF-MS].

    PubMed

    Liu, Ye; Wei, Wen-Feng; Huo, Jin-Hai; Wang, Wei-Ming

    2017-02-01

    To analyze the main components of Qinbai Qingfei concentrated pellets in rat serum with UPLC-Q-TOF-MS technology and serum pharmacochemistry theory. After gavage administration with Qinbai Qingfei concentrated pellets, blood was collected from hepatic portal vein. ACQUITY UPLC BEH C₁₈(2.1 mm×100 mm, 1.7 μm) was used, with 0.1% formic acid agueous solution(A)-0.1%formic acid and acetonitrile(B) as the mobile phase for gradient elution. The flow rate was 0.3 mL•min⁻¹, the column temperature was maintained at 35 ℃. Through the comparative analysis fingerprints of Qinbai Qingfei concentrated pellets, drug containing-serum and blank serum, and with the help Peakview and Metabolitepilot software, components in serum were defined. A total of 28 compounds were identified, including 18 prototypes and 10 metabolites. As a result, UPLC-Q-TOF-MS technology and serum pharmacochemistry theory were applied to comprehensively expound Qinbai Qingfei concentrated pellets'constituents migrating to rat serum, and provide scientific basis for further studies for in vivo metabolic process and effective material base. Copyright© by the Chinese Pharmaceutical Association.

  20. Investigation of mechanism and critical parameters for removal of arsenic from water using Zr-TiO2 composite.

    PubMed

    Anđelković, I; Amaizah, N R R; Marković, S B; Stanković, D; Marković, M; Kuzmanović, D; Roglić, G

    2017-09-01

    Using the microwave-hydrothermal method for the synthesis of composite, high surface density of hydroxyl groups, as an active adsorption sites for arsenic, was obtained. Adsorption mechanisms of As(III) and As(V) onto zirconium-doped titanium dioxide (Zr-TiO 2 ) were investigated and proposed using macroscopic and microscopic methods. Obtained results are suggesting inner-sphere and outer-sphere adsorption mechanisms for As(III) and As(V), respectively. This allowed us to identify parameters that are critical for the successful removal of arsenic from water, which is essential information for further optimization of the removal process. The composite was further applied for the removal of As(III) and As(V) from water in a dynamic flow through the reactor. Column study proved that the removal of both arsenic species below the value recommended by WHO can be achieved. Elution of As(III) and As(V) from the composite can be done by using small amounts of 0.01 M NaOH solution resulting in preconcentration of arsenic species and possible multiple usage of composite.

  1. Revascularisation versus medical treatment in patients with stable coronary artery disease: network meta-analysis

    PubMed Central

    Stortecky, Stefan; Stefanini, Giulio G; daCosta, Bruno R; Rutjes, Anne Wilhelmina; Di Nisio, Marcello; Siletta, Maria G; Maione, Ausilia; Alfonso, Fernando; Clemmensen, Peter M; Collet, Jean-Philippe; Cremer, Jochen; Falk, Volkmar; Filippatos, Gerasimos; Hamm, Christian; Head, Stuart; Kappetein, Arie Pieter; Kastrati, Adnan; Knuuti, Juhani; Landmesser, Ulf; Laufer, Günther; Neumann, Franz-Joseph; Richter, Dimitri; Schauerte, Patrick; Sousa Uva, Miguel; Taggart, David P; Torracca, Lucia; Valgimigli, Marco; Wijns, William; Witkowski, Adam; Kolh, Philippe; Juni, Peter

    2014-01-01

    Objective To investigate whether revascularisation improves prognosis compared with medical treatment among patients with stable coronary artery disease. Design Bayesian network meta-analyses to combine direct within trial comparisons between treatments with indirect evidence from other trials while maintaining randomisation. Eligibility criteria for selecting studies A strategy of initial medical treatment compared with revascularisation by coronary artery bypass grafting or Food and Drug Administration approved techniques for percutaneous revascularization: balloon angioplasty, bare metal stent, early generation paclitaxel eluting stent, sirolimus eluting stent, and zotarolimus eluting (Endeavor) stent, and new generation everolimus eluting stent, and zotarolimus eluting (Resolute) stent among patients with stable coronary artery disease. Data sources Medline and Embase from 1980 to 2013 for randomised trials comparing medical treatment with revascularisation. Main outcome measure All cause mortality. Results 100 trials in 93 553 patients with 262 090 patient years of follow-up were included. Coronary artery bypass grafting was associated with a survival benefit (rate ratio 0.80, 95% credibility interval 0.70 to 0.91) compared with medical treatment. New generation drug eluting stents (everolimus: 0.75, 0.59 to 0.96; zotarolimus (Resolute): 0.65, 0.42 to 1.00) but not balloon angioplasty (0.85, 0.68 to 1.04), bare metal stents (0.92, 0.79 to 1.05), or early generation drug eluting stents (paclitaxel: 0.92, 0.75 to 1.12; sirolimus: 0.91, 0.75 to 1.10; zotarolimus (Endeavor): 0.88, 0.69 to 1.10) were associated with improved survival compared with medical treatment. Coronary artery bypass grafting reduced the risk of myocardial infarction compared with medical treatment (0.79, 0.63 to 0.99), and everolimus eluting stents showed a trend towards a reduced risk of myocardial infarction (0.75, 0.55 to 1.01). The risk of subsequent revascularisation was noticeably reduced by coronary artery bypass grafting (0.16, 0.13 to 0.20) followed by new generation drug eluting stents (zotarolimus (Resolute): 0.26, 0.17 to 0.40; everolimus: 0.27, 0.21 to 0.35), early generation drug eluting stents (zotarolimus (Endeavor): 0.37, 0.28 to 0.50; sirolimus: 0.29, 0.24 to 0.36; paclitaxel: 0.44, 0.35 to 0.54), and bare metal stents (0.69, 0.59 to 0.81) compared with medical treatment. Conclusion Among patients with stable coronary artery disease, coronary artery bypass grafting reduces the risk of death, myocardial infarction, and subsequent revascularisation compared with medical treatment. All stent based coronary revascularisation technologies reduce the need for revascularisation to a variable degree. Our results provide evidence for improved survival with new generation drug eluting stents but no other percutaneous revascularisation technology compared with medical treatment. PMID:24958153

  2. Problem-Solving Test: Nucleocytoplasmic Shuttling of Pre-mRNA Binding Proteins

    ERIC Educational Resources Information Center

    Szeberenyi, Jozsef

    2012-01-01

    Terms to be familiar with before you start to solve the test: transcription, pre-mRNA, RNA processing, RNA transport, RNA polymerase II, direct and indirect immunofluorescence staining, cell fractionation by centrifugation, oligo(dT)-cellulose chromatography, washing and elution of the column, ribonuclease, SDS-polyacrylamide gel electrophoresis,…

  3. Simultaneous determination of 15 marker constituents in various radix Astragali preparations by solid-phase extraction and high-performance liquid chromatography.

    PubMed

    Qi, Lian-Wen; Yu, Qing-Tao; Yi, Ling; Ren, Mei-Ting; Wen, Xiao-Dong; Wang, Yu-Xia; Li, Ping

    2008-01-01

    An improved quality control method was developed to simultaneously determine 15 major constituents (eight flavonoids and seven saponins) in various radix Astragali preparations, using SPE for pretreatment of samples, HPLC with diode-array and evaporative light scattering detectors (DAD-ELSD) for quantification in one run, and HPLC-ESI-TOF/MS for definite identification of compounds in preparations. Optimum separations were obtained with a ZORBAX C(18) column, using a gradient elution with 0.3% aqueous formic acid and ACN. This established method was fully validated with respect to linearity, precision, repeatability, and accuracy, and was successfully applied to quantify the 15 compounds in 19 commercial samples, including 3 dosage forms, i. e., oral solution, injection, concentrated granule, and its processed products of radix Astragali. The results demonstrated that many factors might result in significant differences in quality of the final preparations, including crude drugs, pretreatment processes, manufacturing procedure, storage conditions, etc. Then the developed method provided a reasonable and powerful manner to ensure the efficacy, safety, and batch-to-batch uniformity of radix Astragali products by standardizing each procedure, and thus should be proposed as quality control for the clinical use and modernization of herbal preparations.

  4. Incorporating Platelet-Rich Plasma into Electrospun Scaffolds for Tissue Engineering Applications

    PubMed Central

    Wolfe, Patricia S.; Ericksen, Jeffery J.; Simpson, David G.; Bowlin, Gary L.

    2011-01-01

    Platelet-rich plasma (PRP) therapy has seen a recent spike in clinical interest due to the potential that the highly concentrated platelet solutions hold for stimulating tissue repair and regeneration. The aim of this study was to incorporate PRP into a number of electrospun materials to determine how growth factors are eluted from the structures, and what effect the presence of these factors has on enhancing electrospun scaffold bioactivity. PRP underwent a freeze-thaw-freeze process to lyse platelets, followed by lyophilization to create a powdered preparation rich in growth factors (PRGF), which was subsequently added to the electrospinning process. Release of protein from scaffolds over time was quantified, along with the quantification of human macrophage and adipose-derived stem cell (ADSC) chemotaxis and proliferation. Protein assays demonstrated a sustained release of protein from PRGF-containing scaffolds at up to 35 days in culture. Scaffold bioactivity was enhanced as ADSCs demonstrated increased proliferation in the presence of PRGF, whereas macrophages demonstrated increased chemotaxis to PRGF. In conclusion, the work performed in this study demonstrated that the incorporation of PRGF into electrospun structures has a significant positive influence on the bioactivity of the scaffolds, and may prove beneficial in a number of tissue engineering applications. PMID:21679135

  5. Mineralogical determination and geo-chemical modeling of chromium release from AOD slag: Distribution and leachability aspects.

    PubMed

    Li, Junguo; Liu, Bao; Zeng, Yanan; Wang, Ziming

    2017-01-01

    AOD (argon oxygen decarburization) slag, which is the by-product of the stainless steel refining process, is a recyclable slag because of its high content of calcium and silicon. The leaching toxicity cannot be ignored in the recycling process because the slag contains a certain amount of Cr. In this study, the mineral analysis, batch leaching tests and thermodynamic and kinetic modeling by PHREEQC combined with FactSage software were performed to explore the influence of the dissolution of primary minerals and the precipitation of secondary minerals on the elution of Cr from AOD slag. The results indicated that the main minerals in the original AOD slag are larnite, merwinite, pyroxene and periclase. Cr was dispersed in the mineral phases mentioned above. The simulation of Cr leaching controlled by Cr(III)-hydroxide corresponded better to the batch leaching tests, while the Cr leaching controlled by chromite or double control was underestimated. Increasing the L/S ratio enhances the pH of the leachate and restrains the elution of Cr from the AOD slag. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. FTA card utility for PCR detection of Mycobacterium leprae.

    PubMed

    Aye, Khin Saw; Matsuoka, Masanori; Kai, Masanori; Kyaw, Kyaw; Win, Aye Aye; Shwe, Mu Mu; Thein, Min; Htoo, Maung Maung; Htoon, Myo Thet

    2011-01-01

    The suitability of the FTA® elute card for the collection of slit skin smear (SSS) samples for PCR detection of Mycobacterium leprae was evaluated. A total of 192 SSS leprosy samples, of bacillary index (BI) 1 to 5, were collected from patients attending two skin clinics in Myanmar and preserved using both FTA® elute cards and 70% ethanol tubes. To compare the efficacy of PCR detection of DNA from each BI class, PCR was performed to amplify an M. leprae-specific repetitive element. Of the 192 samples, 116 FTA® elute card and 112 70% ethanol samples were PCR positive for M. leprae DNA. When correlated with BI, area under the curve (AUC) values of the respective receiver-operating characteristic curves were similar for the FTA® elute card and ethanol collection methods (AUC=0.6). Taken together, our results indicate that the FTA® elute card, which enables the collection, transport, and archiving of clinical samples, is an attractive alternative to ethanol preservation for the detection of M. leprae DNA.

  7. Investigating desorption during ethanol elution to improve the quality and antioxidant activity of xylo-oligosaccharides from corn stalk.

    PubMed

    Zhang, Jie; Wang, Yue-Hai; Wei, Quan-Yuan; Du, Xiao-Jia; Qu, Yong-Shui

    2018-02-01

    As the most representative of lignocellulosic materials, corn stalk (CS) will be a great candidate to produce xylo-oligosaccharides (XOS). Owing to the high impurity content of the XOS produced by directly enzymatic hydrolysis of xylan extracted from CS, subsequent refining steps are essential. The present study was aimed to investigate desorption during ethanol elution to improve the quality and antioxidant activity of XOS from CS. The desorption was systematically investigated after optimizing the elution conditions. The results showed that it had an elution watershed when the volume ratio was 2:1. More interestingly, XOS had a obvious priorities of desorption during ethanol gradient elution. The highest purity of XOS was 98.12% from 30% ethanol eluate. Antioxidant activity assay showed that the highest radical scavenging activity of XOS was 89.89% obtained from 70% ethanol eluate at a concentration of 3 mg/mL, which could be used in antioxidant food, feed additives. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. [The effect of denture base resins coated with antibacterial coating on water sorption, solubility and monomer elution].

    PubMed

    Yang, Yang; Gong, Hai-Huan; Song, Ai-Yang; Feng, Dan; Jin, Jie; Zhu, Song

    2015-02-01

    To determine the influence of denture base resins coated with antibacterial coating on water sorption, solubility and monomer elution. The values of water sorption and solubility were measured according to YY 0270-2003 and gas chromatography was used to examine the leachability of 4 commercially available heat-cured acrylic resins between experimental group and control group. Degree of crosslinking of the experimental heat-cured acrylic denture bases we remeasured by soxhlet extraction method. The data was analyzed by 17.0 software package. The values of water sorption, solubility and monomer elution of experimental group were lower compared to the control group. Degree of crosslinking of Heraeus reins was the highest among the experimental heat-cured acrylic denture bases. There is a same trend among water sorption, degree of crosslinking and the monomer elution. When the degree of crosslinking increases, the values of water sorption and monomer elution decrease. Antibacterial coating can improve the comprehensive properties of the denture base resins.

  9. Clinical evaluation of human papillomavirus detection by careHPV™ test on physician-samples and self-samples using the indicating FTA Elute® card.

    PubMed

    Wang, Shao-Ming; Hu, Shang-Ying; Chen, Feng; Chen, Wen; Zhao, Fang-Hui; Zhang, Yu-Qing; Ma, Xin-Ming; Qiao, You-Lin

    2014-01-01

    To make the clinical evaluation of a solid-state human papillomavirus (HPV) sampling medium in combination with an economical HPV testing method (careHPV™) for cervical cancer screening. 396 women aged 25-65 years were enrolled for cervical cancer screening, and four samples were collected. Two samples were collected by woman themselves, among which one was stored in DCM preservative solution (called "liquid sample") and the other was applied on the Whatman Indicating FTA Elute® card (FTA card). Another two samples were collected by physician and stored in DCM preservative solution and FTA card, respectively. All the samples were detected by careHPV™ test. All the women were administered a colposcopy examination, and biopsies were taken for pathological confirmation if necessary. FTA card demonstrated a comparable sensitivity of detecting high grade Cervical Intraepithelial Neoplasia (CIN) with the liquid sample carrier for self and physician-sampling, but showed a higher specificity than that of liquid sample carrier for self-sampling (FTA vs Liquid: 79.0% vs 71.6%, p=0.02). Generally, the FTA card had a comparable accuracy with that of Liquid-based medium by different sampling operators, with an area under the curve of 0.807 for physician and FTA, 0.781 for physician and Liquid, 0.728 for self and FTA, and 0.733 for self and Liquid (p>0.05). FTA card is a promising sample carrier for cervical cancer screening. With appropriate education programmes and further optimization of the experimental workflow, FTA card based self-collection in combination with centralized careHPV™ testing can help expand the coverage of cervical cancer screening in low-resource areas.

  10. Injectable Drug Eluting Elastomeric Polymer: A Novel Submucosal Injection Material

    PubMed Central

    Tran, Richard T.; Palmer, Michael; Tang, Shou-Jiang; Abell, Thomas L.; Yang, Jian

    2011-01-01

    Background Biodegradable hydrogels can deliver therapeutic payloads with great potentials in endoscopic mucosal resection (EMR) and endoscopic submucosal dissection (ESD) to yield improvements in efficacy and foster mucosal regeneration. Objective To assess the efficacy of an injectable drug eluting elastomeric polymer (iDEEP) as a submucosal injection material. Design Comparative study among 3 different solutions using material characterization tests, ex vivo and in vivo porcine models. Setting Academic hospital. Interventions 30 gastric submucosal cushions were achieved with saline (0.9%), sodium hyaluronate (0.4%), and iDEEP (n = 10) in ex vivo porcine stomachs. Four porcine gastric submucosal cushions were then performed in vivo using iDEEP. Main outcome measurements Maximum injection pressure, Rebamipide release rate, submucosal elevation duration, and assessment of in vivo efficacy by en bloc resection. Results No significant difference in injection pressures between iDEEP (28.9 ± 0.3 PSI) and sodium hyaluronate (29.5 ± 0.4 PSI, P > .05) was observed. iDEEP gels displayed a controlled release of Rebamipide up to 2 weeks in vitro. The elevation height of iDEEP (5.7 ± 0.5 mm) was higher than saline (2.8 ± 0.2 mm, P < .01) and SH (4.2 ± 0.2 mm, P < .05). All EMR procedures were successfully performed after injection of iDEEP, and a large gel cushion was noted after the resection procedure. Limitations Benchtop, ex vivo, and non-survival pig study. Conclusions A novel injection solution was evaluated for endoscopic resection. These results suggest that iDEEP may provide a significant step towards the realization of an ideal EMR and ESD injection material. PMID:22301346

  11. Quality by design (QbD) based development and validation of an HPLC method for amiodarone hydrochloride and its impurities in the drug substance.

    PubMed

    Karmarkar, S; Yang, X; Garber, R; Szajkovics, A; Koberda, M

    2014-11-01

    The USP monograph describes an HPLC method for seven impurities in the amiodarone drug substance using a L1 column, 4.6mm×150mm, 5μm packing (PF listed ODS2 GL-Science, Inertsil column) at 30°C with detection at 240nm. The standard contains 0.01mg/mL of amiodarone, and USP specified impurities D and E with a resolution requirement of NLT 3.5 between peaks D and E. Impurities in a 5mg/mL sample are quantitated against the standard. Impurity A peak elutes just before peak D. We observed two problems with the method; the column lot-to-lot variability resulted in unresolved A, D, and E peaks, and peak D in the sample preparation eluted much later than that in the standard solution. Therefore, optimization experiments were conducted on the USP method following the QbD approach with Fusion AE™ software (S-Matrix Corporation). The resulting optimized conditions were within the allowable changes per USP 〈621〉. Lot-to-lot variability was negligible with the Atlantis T3 (Waters Corporation) L1 column. Peak D retention time remained constant from standard to sample. The optimized method was validated in terms of accuracy, precision, linearity, range, LOQ/LOD, specificity, robustness, equivalency to the USP method, and solution stability. The QbD based development helped in generating a design space and operating space with knowledge of all method performance characteristics and limitations and successful method robustness within the operating space. Copyright © 2014 Elsevier B.V. All rights reserved.

  12. Radionuclide migration: laboratory experiments with isolated fractures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rundberg, R.S.; Thompson, J.L.; Maestas, S.

    Laboratory experiments examining flow and element migration in rocks containing isolated fractures have been initiated at the Los Alamos National Laboratory. Techniques are being developed to establish simple fracture flow systems which are appropriate to models using analytical solutions to the matrix diffusion-flow equations, such as those of I. Neretnieks [I. Neretnieks, Diffusion in the Rock Matrix: An Important Factor in Radionuclide Retardation? J. Geophys. Res. 85, 4379 (1980).] These experiments are intended to be intermediate steps toward larger scale field experiments where it may become more difficult to establish and control the parameters important to nuclide migration in fracturedmore » media. Laboratory experiments have been run on fractures ranging in size from 1 to 20 cm in length. The hydraulic flow in these fractures was studied to provide the effective apertures. The flows established in these fracture systems are similar to those in the granite fracture flow experiments of Witherspoon et al. [P.A. Witherspoon, J.S.Y. Wang, K. Iwai, and J.E. Gale, Validity of Cubic Law for Fluid Flow in a Deformable Rock Fracture, Lawrence Berkeley Laboratory report LBL-9557 (October 1979).] Traced solutions containing {sup 85}Sr and {sup 137}Cs were flowed through fractures in Climax Stock granite and welded tuff (Bullfrog and Tram members, Yucca Mountain, Nevada Test Site). The results of the elutions through granite agree with the matrix diffusion calculations based on independent measurements of K/sub d/. The results of the elutions through tuff, however, agree only if the K/sub d/ values used in the calculations are lower than the K/sub d/ values measured using a batch technique. This trend has been previously observed in chromatographic column experiments with tuff. 5 figures, 3 tables.« less

  13. Linkage of iron elution and dissolved oxygen consumption with removal of organic pollutants by nanoscale zero-valent iron: Effects of pH on iron dissolution and formation of iron oxide/hydroxide layer.

    PubMed

    Fujioka, Nanae; Suzuki, Moe; Kurosu, Shunji; Kawase, Yoshinori

    2016-02-01

    The iron elution and dissolved oxygen (DO) consumption in organic pollutant removal by nanoscale zero-valent iron (nZVI) was examined in the range of solution pH from 3.0 to 9.0. Their behaviors were linked with the removal of organic pollutant through the dissolution of iron and the formation of iron oxide/hydroxide layer affected strongly by solution pH and DO. As an example of organic pollutants, azo-dye Orange II was chosen in this study. The chemical composition analyses before and after reaction confirmed the corrosion of nZVI into ions, the formation of iron oxide/hydroxide layer on nZVI surface and the adsorption of the pollutant and its intermediates. The complete decolorization of Orange II with nZVI was accomplished very quickly. On the other hand, the total organic carbon (TOC) removal was considerably slow and the maximum TOC removal was around 40% obtained at pH 9.0. The reductive cleavage of azo-bond by emitted electrons more readily took place as compared with the cleavage of aromatic rings of Orange II leading to the degradation to smaller molecules and subsequently the mineralization. A reaction kinetic model based on the Langmuir-Hinshelwood/Eley-Rideal approach was developed to elucidate mechanisms for organic pollutant removal controlled by the formation of iron oxide/hydroxide layer, the progress of which could be characterized by considering the dynamic concentration changes in Fe(2+) and DO. The dynamic profiles of Orange II removal linked with Fe(2+) and DO could be reasonably simulated in the range of pH from 3.0 to 9.0. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. Characterization of ultrahigh-molecular weight cationic polyacrylamide using frit-inlet asymmetrical flow field-flow fractionation and multi-angle light scattering.

    PubMed

    Woo, Sohee; Lee, Ju Yong; Choi, Woonjin; Moon, Myeong Hee

    2016-01-15

    In this study, frit inlet asymmetrical flow field-flow fractionation (FlFFF) with multi-angle light scattering (MALS) and differential refractive index (DRI) detection is utilized for size separation, determination of molecular weight (MW), and conformation of ultrahigh-MW (10(7)-10(9) g/mol) cationic polyacrylamides (C-PAMs), a class of water-soluble copolymers based on acrylamide and vinyl-type comonomers with quaternary ammonium cations that are widely used in wastewater treatment and in paper industries. Linear and branched C-PAM copolymers prepared in two different polymerization methods (solution and emulsion) from varying amounts of crosslinking agent and initiator were size fractionated by FlFFF with field-programming. It was found experimentally that the linear copolymers from both polymerization methods were less than 10(8) g/mol in MW with compact, nearly spherical structures, while the branched C-PAM copolymers from the emulsion polymerization showed a significant increase in average MW up to ∼ 10(9)g/mol, which was about 20-fold greater than those from the solution method, and the branched copolymers had more compact or shrunken conformations. While both linear and branched copolymers less than 10(8) g/mol MW were well resolved in an increasing order of MW (normal mode), it was noted that branched copolymers prepared through emulsion polymerization exhibited significantly larger MWs of 10(8-)10(9) g/mol and eluted in the steric/hyperlayer mode, in which the elution order is reversed in an extreme run condition (strong initial field strength followed by a fast field decay during programming). Copyright © 2015 Elsevier B.V. All rights reserved.

  15. Impact of ultrasonic time on hot water elution of severely biodegraded heavy oil from weathered soils.

    PubMed

    Ji, Guodong; Sui, Xin

    2010-07-15

    An ultrasound-enhanced elution system employing water at a temperature of 70 degrees C was used to remedy weathered soils contaminated with severely biodegraded heavy oil (SBHO). The effect of varying the ultrasonic irradiation time from 0 to 1800 s on the elution of SBHO and three characteristic biomarkers (C(26-34) 17alpha 25-norhopanes, C(26-28) TAS, and C(27-29) MTAS) was analyzed using GC/MS, scanning electron microscopy (SEM), and X-ray diffraction (XRD). Elution of the three biomarkers was closely related to the carbon number of the marker. C(26-34) 17alpha 25-norhopanes and C(26-28) TAS species with higher carbon numbers and C(27-29) MTAS species with lower carbon numbers were more readily eluted using sonication times of 1080-1800 s, while smaller TAS homologs were more readily eluted after sonication times of 0-360 s. SEM images of samples treated for longer periods revealed larger "bare patches" on the soil surface. The results of XRD and energy spectroscopy experiments indicated that ultrasound irradiation for 1080 s negatively affected the deposition of CaCO(3), but overall improved the mineral and chemical compositions of treated soils and removal of SBHO. 2010 Elsevier B.V. All rights reserved.

  16. Drug elution from high-dose antibiotic-loaded acrylic cement: a comparative, in vitro study.

    PubMed

    Gasparini, Giorgio; De Gori, Marco; Calonego, Giovanni; Della Bora, Tommaso; Caroleo, Benedetto; Galasso, Olimpio

    2014-11-01

    High-dose antibiotic-loaded acrylic cement (ALAC) is used for managing peri-prosthetic joint infections (PJIs). The marked increase in resistant high-virulence bacteria is drawing the attention of physicians toward alternative antimicrobial formulations loaded into acrylic bone cement. The aim of this in vitro study was to determine the elution kinetics of 14 different high-dose ALACs. All ALAC samples showed a burst release of antibiotics in the first hour, progressively decreasing over time, and elution curves strictly adhered to a nonlinear regression analysis formula. Among aminoglycosides, commonly seen as the most appropriate antibiotics to be loaded into the bone cement, the highest elution rate was that of tobramycin. Among the glycopeptides, a class of antibiotics that should be considered to treat PJIs because of the prevalence of aminoglycoside resistance, vancomycin showed better elution than teicoplanin. Clindamycin, which can be associated with aminoglycosides to prepare ALACs and represents a useful option against the most common pathogens responsible for PJIs, showed the highest absolute and relative elutions among all the tested formulations. A noticeable elution was also detected for colistin, an antibiotic of last resort for treating multidrug-resistant bacteria. The current study demonstrates theoretical advantages in the preparation of ALAC for some antibiotics not routinely used in the clinical setting for PJIs. The use of these antibiotics based on the infecting bacteria sensitivity may represent a useful option for physicians to eradicate PJIs. In vivo testing should be considered in the future to confirm the results of this study. Copyright 2014, SLACK Incorporated.

  17. Paclitaxel Drug-eluting Tracheal Stent Could Reduce Granulation Tissue Formation in a Canine Model

    PubMed Central

    Wang, Ting; Zhang, Jie; Wang, Juan; Pei, Ying-Hua; Qiu, Xiao-Jian; Wang, Yu-Ling

    2016-01-01

    Background: Currently available silicone and metallic stents for tracheal stenosis are associated with many problems. Granulation proliferation is one of the main complications. The present study aimed to evaluate the efficacy of paclitaxel drug-eluting tracheal stent in reducing granulation tissue formation in a canine model, as well as the pharmacokinetic features and safety profiles of the coated drug. Methods: Eight beagles were randomly divided into a control group (bare-metal stent group, n = 4) and an experimental group (paclitaxel-eluting stent group, n = 4). The observation period was 5 months. One beagle in both groups was sacrificed at the end of the 1st and 3rd months, respectively. The last two beagles in both groups were sacrificed at the end of 5th month. The proliferation of granulation tissue and changes in tracheal mucosa were compared between the two groups. Blood routine and liver and kidney function were monitored to evaluate the safety of the paclitaxel-eluting stent. The elution method and high-performance liquid chromatography were used to characterize the rate of in vivo release of paclitaxel from the stent. Results: Compared with the control group, the proliferation of granulation tissue in the experimental group was significantly reduced. The drug release of paclitaxel-eluting stent was the fastest in the 1st month after implantation (up to 70.9%). Then, the release slowed down gradually. By the 5th month, the release reached up to 98.5%. During the observation period, a high concentration of the drug in the trachea (in the stented and adjacent unstented areas) and lung tissue was not noted, and the blood test showed no side effect. Conclusions: The paclitaxel-eluting stent could safely reduce the granulation tissue formation after stent implantation in vivo, suggesting that the paclitaxel-eluting tracheal stent might be considered for potential use in humans in the future. PMID:27824004

  18. Outcomes with the paclitaxel-eluting stent in patients with acute coronary syndromes: analysis from the TAXUS-IV trial.

    PubMed

    Moses, Jeffrey W; Mehran, Roxana; Nikolsky, Eugenia; Lasala, John M; Corey, Woodrow; Albin, Glenn; Hirsch, Cary; Leon, Martin B; Russell, Mary E; Ellis, Stephen G; Stone, Gregg W

    2005-04-19

    We sought to investigate the outcomes of paclitaxel-eluting stent implantation in patients with unstable angina or non-ST-segment elevation myocardial infarction undergoing percutaneous coronary intervention (PCI). Whether the paclitaxel-eluting stent is safe and effective in patients with acute coronary syndromes (ACS) is unknown. In the TAXUS-IV trial, 1,314 patients with stable or unstable ischemic syndromes undergoing PCI were randomized to treatment with either the slow-release, polymer-based, paclitaxel-eluting TAXUS stent or a bare-metal EXPRESS stent (Boston Scientific Corp., Natick, Massachusetts). The results were stratified by the acuity of the presenting clinical syndrome. Acute coronary syndromes were present in 450 patients (34.2%), 237 of whom were assigned to paclitaxel-eluting stents and 213 to bare-metal stents. The baseline and procedural characteristics were well matched between the groups. Clinical outcomes at 30 days were similar with both stents. At one-year follow-up, patients with ACS assigned to the paclitaxel-eluting stent compared to the control stent had strikingly lower rates of target lesion revascularization (TLR) (3.9% vs. 16.0%, p < 0.0001) and major adverse cardiac events (11.1 vs. 21.7%, p = 0.002). By multivariate analysis, ACS was an independent predictor of in-stent restenosis in the cohort treated with bare-metal stents (hazard ratio [HR] = 2.03 [95% confidence interval (CI) 1.05 to 3.92], p = 0.035), while among patients randomized to the paclitaxel-eluting stents, ACS was an independent predictor of freedom from restenosis (HR = 0.27 [95% CI 0.08 to 0.97], p = 0.04). The use of the paclitaxel-eluting TAXUS stent was safe in patients with unstable ischemic syndromes, and was associated with marked reduction of ischemia-driven TLR and adverse cardiac events at one year.

  19. Comparison of the Efficacy of Everolimus-Eluting Stents Versus Drug-Eluting Balloons in Patients With In-Stent Restenosis (from the RIBS IV and V Randomized Clinical Trials).

    PubMed

    Alfonso, Fernando; Pérez-Vizcayno, María José; García Del Blanco, Bruno; García-Touchard, Arturo; Masotti, Mónica; López-Minguez, José R; Iñiguez, Andrés; Zueco, Javier; Velazquez, Maite; Cequier, Angel; Lázaro-García, Rosa; Martí, Vicens; Moris, César; Urbano-Carrillo, Cristobal; Bastante, Teresa; Rivero, Fernando; Cárdenas, Alberto; Gonzalo, Nieves; Jiménez-Quevedo, Pilar; Fernández, Cristina

    2016-02-15

    Treatment of patients with in-stent restenosis (ISR) remains a challenge. This study sought to compare the efficacy of everolimus-eluting stents (EESs) and drug-eluting balloons (DEBs) with paclitaxel in patients with ISR. A pooled analysis of the Restenosis Intra-Stent of Drug-Eluting Stents: Drug-Eluting Balloon vs Everolimus-Eluting Stent (RIBS IV) and Restenosis Intra-Stent of Bare-Metal Stents: Drug-Eluting Balloon vs Everolimus-Eluting Stent (RIBS V) randomized trials was performed using patient-level data. In both trials, EESs were compared with DEBs in patients with ISR (RIBS V included 189 patients with bare-metal ISR; RIBS IV included 309 patients with drug-eluting ISR). Inclusion and exclusion criteria were identical in both trials. A total of 249 patients were allocated to EES and 249 to DEB. Clinical follow-up at 1 year was obtained in all (100%) patients and late angiography (median 249 days) in 91% of eligible patients. Compared with patients treated with DEBs, patients treated with EESs obtained better short-term results (postprocedural minimal lumen diameter 2.28 ± 0.5 vs 2.12 ± 0.4 mm, p <0.0001). At follow-up, patients treated with EESs had larger in-segment minimal lumen diameter (primary end point 2.16 ± 0.7 vs 1.88 ± 0.6 mm, p <0.0001; absolute mean difference 0.28 mm; 95% confidence interval [CI] 0.16 to 0.40) and net lumen gain (1.33 ± 0.6 vs 1.00 ± 0.7 mm, p <0.0001) and had lower %diameter stenosis (19 ± 21% vs 28 ± 22%, p <0.0001) and binary restenosis rate (8.7% vs 15.7%, p = 0.02). Consistent results were observed in the in-lesion analysis. No interactions were found between the underlying stent type and treatment effects. At 1-year clinical follow-up, the composite of cardiac death, myocardial infarction, and target vessel revascularization was significantly reduced in the EES arm (8.8% vs 14.5%, p = 0.03; hazard ratio 0.59, 95% CI 0.31 to 0.94) mainly driven by a lower need for target vessel revascularization (6% vs 12.4%, p = 0.01, hazard ratio 0.46, 95% CI 0.25 to 0.86). This pooled analysis of the RIBS IV and RIBS V randomized trials demonstrates the superiority of EES over DEB in the treatment of patients with ISR. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Hydroxyapatite Based 99Mo - 99Tc and 188W - 188Re Generator Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Knapp Jr, Russ F; Monroy-Guzman, F.; Badillo, V. E.

    2006-01-01

    This paper describes studies evaluating the use of hydroxyapatite as the adsorbent material for both {sup 99}Mo-{sup 99m}Tc and {sup 188}W-{sup 188}Re generator systems. Hydroxyapatite is an insoluble solid with anion exchange properties. A study of the sorption behaviour of {sup 99}Mo, {sup 99m}Tc, {sup 188}W and {sup 188}Re on hydroxyapatite in NaCl medium was evaluated by batch experiments. The results demonstrated that while {sup 99}Mo, {sup 99m}Tc and {sup 188}Re are not adsorbed by the hydroxyapatite in NaCl solutions (Kd <5), {sup 188}W is strongly adsorbed (Kd >500). On the basis of these measurements, hydroxyapatite {sup 188}W-{sup 188}Re generatormore » systems were then constructed and eluted in NaCl solutions. The hydroxyapatite based {sup 188}W-{sup 188}Re generator performances are presented.« less

  1. [Application of solid-phase extraction column for determination of matrine and oxymatrine in Sophora flavescens].

    PubMed

    Yang, Xia; Guo, Bao-Lin; Hu, Hong-Yu; Huang, Wen-Hua; Qiao, He-Ping; Fan, Sheng-Ci; Guan, Zha-Gen

    2013-09-01

    A Cleanert Alumina-N-SPE column (0.5 g/6 mL) chromatograpy with 5 mL of chloroform-methanol (7: 3) as eluent, instead of aluminum oxide column (100-200 mesh, 5 g, 1 cm) chromatograpy eluted successively with chloroform and the chloroform-methanol (7:3) (20 mL each), was applied to enrich matrine and oxymatrine in Sophora flavescens. Also, the optimization of the HPLC determination conditions with acetonitrile-ethanol absolute-3% phosphoric acid solution (84: 6: 10) as mobile phase, instead of acetonitrile-ethanol absolute -3% Phosphoric acid solution (80: 10: 10) recorded in Chinese Pharmacopoeia 2010 Edition, was more suitable for determination of matrine and oxymatrine in S. flavescens. This method has advantage of reducing sample handling time and solvent volume and increasing the accuracy and feasibility, which can simplify the procedure for determination of matrine and oxymatrine in S. flavescens.

  2. DNA elution from buccal cells stored on Whatman FTA Classic Cards using a modified methanol fixation method.

    PubMed

    Johanson, Helene C; Hyland, Valentine; Wicking, Carol; Sturm, Richard A

    2009-04-01

    We describe here a method for DNA elution from buccal cells and whole blood both collected onto Whatman FTA technology, using methanol fixation followed by an elution PCR program. Extracted DNA is comparable in quality to published Whatman FTA protocols, as judged by PCR-based genotyping. Elution of DNA from the dried sample is a known rate-limiting step in the published Whatman FTA protocol; this method enables the use of each 3-mm punch of sample for several PCR reactions instead of the standard, one PCR reaction per sample punch. This optimized protocol therefore extends the usefulness and cost effectiveness of each buccal swab sample collected, when used for nucleic acid PCR and genotyping.

  3. Description of Adsorption in Liquid Chromatography under Nonideal Conditions.

    PubMed

    Ortner, Franziska; Ruppli, Chantal; Mazzotti, Marco

    2018-05-15

    A thermodynamically consistent description of binary adsorption in reversed-phase chromatography is presented, accounting for thermodynamic nonidealities in the liquid and adsorbed phases. The investigated system involves the adsorbent Zorbax 300SB-C18, as well as phenetole and 4- tert-butylphenol as solutes and methanol and water as inert components forming the eluent. The description is based on adsorption isotherms, which are a function of the liquid-phase activities, to account for nonidealities in the liquid phase. Liquid-phase activities are calculated with a UNIQUAC model established in this work, based on experimental phase equilibrium data. The binary interaction in the adsorbed phase is described by the adsorbed solution theory, assuming an ideal (ideal adsorbed solution theory) or real (real adsorbed solution theory) adsorbed phase. Implementation of the established adsorption model in a chromatographic code achieves a quantitative description of experimental elution profiles, with feed compositions exploiting the entire miscible region, and involving a broad range of different eluent compositions (methanol/water). The quantitative agreement of the model and experimental data serves as a confirmation of the underlying physical (thermodynamic) concepts and of their applicability to a broad range of operating conditions.

  4. Protein separation through preliminary experiments concerning pH and salt concentration by tube radial distribution chromatography based on phase separation multiphase flow using a polytetrafluoroethylene capillary tube.

    PubMed

    Kan, Hyo; Tsukagoshi, Kazuhiko

    2017-07-01

    Protein mixtures were separated using tube radial distribution chromatography (TRDC) in a polytetrafluoroethylene (PTFE) capillary (internal diameter=100µm) separation tube. Separation by TRDC is based on the annular flow in phase separation multiphase flow and features an open-tube capillary without the use of specific packing agents or application of high voltages. Preliminary experiments were conducted to examine the effects of pH and salt concentration on the phase diagram of the ternary mixed solvent solution of water-acetonitrile-ethyl acetate (8:2:1 volume ratio) and on the TRDC system using the ternary mixed solvent solution. A model protein mixture containing peroxidase, lysozyme, and bovine serum albumin was analyzed via TRDC with the ternary mixed solvent solution at various pH values, i.e., buffer-acetonitrile-ethyl acetate (8:2:1 volume ratio). Protein was separated on the chromatograms by the TRDC system, where the elution order was determined by the relation between the isoelectric points of protein and the pH values of the solvent solution. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. A technique for rapid source apportionment applied to ambient organic aerosol measurements from a thermal desorption aerosol gas chromatograph (TAG)

    DOE PAGES

    Zhang, Yaping; Williams, Brent J.; Goldstein, Allen H.; ...

    2016-11-25

    Here, we present a rapid method for apportioning the sources of atmospheric organic aerosol composition measured by gas chromatography–mass spectrometry methods. Here, we specifically apply this new analysis method to data acquired on a thermal desorption aerosol gas chromatograph (TAG) system. Gas chromatograms are divided by retention time into evenly spaced bins, within which the mass spectra are summed. A previous chromatogram binning method was introduced for the purpose of chromatogram structure deconvolution (e.g., major compound classes) (Zhang et al., 2014). Here we extend the method development for the specific purpose of determining aerosol samples' sources. Chromatogram bins are arrangedmore » into an input data matrix for positive matrix factorization (PMF), where the sample number is the row dimension and the mass-spectra-resolved eluting time intervals (bins) are the column dimension. Then two-dimensional PMF can effectively do three-dimensional factorization on the three-dimensional TAG mass spectra data. The retention time shift of the chromatogram is corrected by applying the median values of the different peaks' shifts. Bin width affects chemical resolution but does not affect PMF retrieval of the sources' time variations for low-factor solutions. A bin width smaller than the maximum retention shift among all samples requires retention time shift correction. A six-factor PMF comparison among aerosol mass spectrometry (AMS), TAG binning, and conventional TAG compound integration methods shows that the TAG binning method performs similarly to the integration method. However, the new binning method incorporates the entirety of the data set and requires significantly less pre-processing of the data than conventional single compound identification and integration. In addition, while a fraction of the most oxygenated aerosol does not elute through an underivatized TAG analysis, the TAG binning method does have the ability to achieve molecular level resolution on other bulk aerosol components commonly observed by the AMS.« less

  6. New analytical techniques for mycotoxins in complex organic matrices

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bicking, M.K.L.

    1982-01-01

    Air samples are collected for analysis from the Ames Solid Waste Recovery System. The high level of airborne fungi within the processing area is of concern due to the possible presence of toxic mycotoxins, and carcinogenic fungal metabolites. An analytical method has been developed to determine the concentration of aflatoxins B1, B2, G1, and G2 in the air of the plant which produces Refuse Derived Fuel (RDF). After extraction with methanol, some components in the matrix are precipitated by dissolving the samples in 30% acetonitrile/chloroform. An aliquot of this solution is injected onto a Styragel column where the sample componentsmore » undergo simultaneous size exclusion and reverse phase partitioning. The Styragel column appears to have a useable lifetime of more than six months. After elution from Styragel, the sample is diverted to a second column containing Florisil which has been modified with oxalic acid and deactivated with water. Aflatoxins are eluted with 5% water/acetone. After removal of this solvent, the sample is dissolved in 150 ..mu..L of a spotting solvent and the entire sample applied to a thin layer chromatography (TLC) plate using a unique sample applicator developed here. The aflatoxins on the TLC plate are analyzed by laser fluorescence. A detection limit of 10 pg is possible for aflatoxin standards using a nitrogen laser as the excitation source. Sample concentrations are determined by comparing with an internal standard, a specially synthesized aflatoxin derivative. In two separate RDF samples, aflatoxin B1 was found at levels of 6.5 and 17.0 ppB. In a separate study, the spore pigment in Aspergillus flavus was isolated. The mass spectrum indicates a molecular weight in excess of 700. Only aliphatic hydrocarbons have been identified in the mass spectrum of products from a permanganate oxidation.« less

  7. New analytical techniques for mycotoxins in complex organic matrices. [Aflatoxins B1, B2, G1, and G2

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bicking, M.K.L.

    1982-07-01

    Air samples are collected for analysis from the Ames Solid Waste Recovery System. The high level of airborne fungi within the processing area is of concern due to the possible presence of toxic mycotoxins, and carcinogenic fungal metabolites. An analytical method has been developed to determine the concentration of aflatoxins B1, B2, G1, and G2 in the air of the plant which produces Refuse Derived Fuel (RDF). After extraction with methanol, some components in the matrix are precipitated by dissolving the sample in 30% acetonitrile/chloroform. An aliquot of this solution is injected onto a Styragel column where the sample componentsmore » undergo simultaneous size exclusion and reverse phase partitioning. Additional studies have provided a more thorough understanding of solvent related non-exclusion effects on size exclusion gels. The Styragel column appears to have a useable lifetime of more than six months. After elution from Styragel, the sample is diverted to a second column containing Florisil which has been modified with oxalic acid and deactivated with water. Aflatoxins are eluted with 5% water/acetone. After removal of this solvent, the sample is dissolved in 150 ..mu..L of a spotting solvent and the entire sample applied to a thin layer chromatography (TLC) plate using a unique sample applicator developed here. The aflatoxins on the TLC plate are analyzed by laser fluorescence. A detection limit of 10 pg is possible for aflatoxin standards using a nitrogen laser as the excitation source. Sample concentrations are determined by comparing with an internal standard, a specially synthesized aflatoxin derivative. In two separate RDF samples, aflatoxin B1 was found at levels of 6.5 and 17.0 ppB. The analytical method has also proven useful in the analysis of contaminated corn and peanut meal samples. 42 figures, 8 tables.« less

  8. A technique for rapid source apportionment applied to ambient organic aerosol measurements from a thermal desorption aerosol gas chromatograph (TAG)

    NASA Astrophysics Data System (ADS)

    Zhang, Yaping; Williams, Brent J.; Goldstein, Allen H.; Docherty, Kenneth S.; Jimenez, Jose L.

    2016-11-01

    We present a rapid method for apportioning the sources of atmospheric organic aerosol composition measured by gas chromatography-mass spectrometry methods. Here, we specifically apply this new analysis method to data acquired on a thermal desorption aerosol gas chromatograph (TAG) system. Gas chromatograms are divided by retention time into evenly spaced bins, within which the mass spectra are summed. A previous chromatogram binning method was introduced for the purpose of chromatogram structure deconvolution (e.g., major compound classes) (Zhang et al., 2014). Here we extend the method development for the specific purpose of determining aerosol samples' sources. Chromatogram bins are arranged into an input data matrix for positive matrix factorization (PMF), where the sample number is the row dimension and the mass-spectra-resolved eluting time intervals (bins) are the column dimension. Then two-dimensional PMF can effectively do three-dimensional factorization on the three-dimensional TAG mass spectra data. The retention time shift of the chromatogram is corrected by applying the median values of the different peaks' shifts. Bin width affects chemical resolution but does not affect PMF retrieval of the sources' time variations for low-factor solutions. A bin width smaller than the maximum retention shift among all samples requires retention time shift correction. A six-factor PMF comparison among aerosol mass spectrometry (AMS), TAG binning, and conventional TAG compound integration methods shows that the TAG binning method performs similarly to the integration method. However, the new binning method incorporates the entirety of the data set and requires significantly less pre-processing of the data than conventional single compound identification and integration. In addition, while a fraction of the most oxygenated aerosol does not elute through an underivatized TAG analysis, the TAG binning method does have the ability to achieve molecular level resolution on other bulk aerosol components commonly observed by the AMS.

  9. Magnetic solid-phase extraction of protein with deep eutectic solvent immobilized magnetic graphene oxide nanoparticles.

    PubMed

    Xu, Kaijia; Wang, Yuzhi; Ding, Xueqin; Huang, Yanhua; Li, Na; Wen, Qian

    2016-01-01

    As a new type of green solvent, four kinds of choline chloride (ChCl)-based deep eutectic solvents (DESs) have been synthesized, and then a core-shell structure magnetic graphene oxide (Fe3O4-NH2@GO) nanoparticles have been prepared and coated with the ChCl-based DESs. Magnetic solid-phase extraction (MSPE) based Fe3O4-NH2@GO@DES was studied for the first time for the extraction of proteins. The characteristic results of vibrating sample magnetometer (VSM), X-ray diffraction (XRD), Fourier transform infrared spectrometry (FT-IR), thermal gravimetric analysis (TGA) and field emission scanning electron microscopy (FESEM) indicated the successful preparation of Fe3O4-NH2@GO@DES. The concentrations of proteins in studies were determined by a UV-vis spectrophotometer. The advantages of Fe3O4-NH2@GO@DES in protein extraction were compared with Fe3O4-NH2@GO and Fe3O4-NH2, and Fe3O4-NH2@GO@ChCl-glycerol was selected as the suitable extraction solvent. The influence factors of the extraction process such as the pH value, the temperature, the extraction time, the concentration of protein and the amount of Fe3O4-NH2@GO@ChCl-glycerol were evaluated. Desorption experimental result showed 98.73% of BSA could be eluted from the solid extractant with 0.1 mol/L Na2HPO4 solution contained 1 mol/L NaCl. Besides, the conformation of BSA was not changed during the elution by the investigation of circular dichromism (CD) spectra. Furthermore, the analysis of real sample demonstrated that the prepared magnetic nanoparticles did have extraction ability on proteins in bovine whole blood. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. Capillary-Channeled Polymer (C-CP) Fibers as a Stationary Phase for Sample Clean-Up of Protein Solutions for Matrix-Assisted Laser/Desorption Ionization Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Manard, Benjamin T.; Marcus, R. Kenneth

    2012-08-01

    Capillary-channeled polymer (C-CP) fibers are employed in a micropipette tip format to affect a stationary phase for the solid phase extraction (SPE) of proteins from buffer solutions prior to MALDI-MS analysis. Proteins readily adsorb to the polypropylene (PP) C-CP fibers while buffer species are easily washed off the tips using DI-H2O. Elution of the solutes is achieved with an aliquot of 50:50 ACN:H2O, which is compatible with the subsequent spotting on the MALDI target with the matrix solution. Lysozyme and cytochrome c are used as test species, with a primary buffer composition of 100 mM Tris-HCl. In this case, direct MALDI-MS produces no discernible protein signals. SPE on the C-CP fibers yields high fidelity mass spectra for 1 μL sample volumes. Limits of detection for cytochrome c in 100 mM Tris-HCl are on the order of 40 nM. Extraction of cytochrome c from buffer concentrations of up to 1 M Tris-HCl, provides signal recoveries that are suppressed by only ~50 % versus neat protein solutions. Finally, extraction of 3.1 μM cytochrome c from a synthetic urine matrix exhibits excellent recovery.

  11. Combining selection valve and mixing chamber for nanoflow gradient generation: Toward developing a liquid chromatography cartridge coupled with mass spectrometer for protein and peptide analysis.

    PubMed

    Chen, Apeng; Lu, Joann J; Gu, Congying; Zhang, Min; Lynch, Kyle B; Liu, Shaorong

    2015-08-05

    Toward developing a micro HPLC cartridge, we have recently built a high-pressure electroosmotic pump (EOP). However, we do not recommend people to use this pump to deliver an organic solvent directly, because it often makes the pump rate unstable. We have experimented several approaches to address this issue, but none of them are satisfactory. Here, we develop an innovative approach to address this issue. We first create an abruption (a dead-volume) within a fluid conduit. We then utilize an EOP to withdraw, via a selection valve, a train of eluent solutions having decreasing eluting power into the fluid conduit. When these solutions are further aspirated through the dead-volume, these solutions are partially mixed, smoothening concentration transitions between two adjacent eluent solutions. As these solutions are pushed back, through the dead-volume again, a smooth gradient profile is formed. In this work, we characterize this scheme for gradient formation, and we incorporate this approach with a high-pressure EOP, a nanoliter injection valve, and a capillary column, yielding a micro HPLC system. We then couple this micro HPLC with an electrospray ionization - mass spectrometer for peptide and protein separations and identifications. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. Method and Apparatus for Automated Isolation of Nucleic Acids from Small Cell Samples

    NASA Technical Reports Server (NTRS)

    Sundaram, Shivshankar; Prabhakarpandian, Balabhaskar; Pant, Kapil; Wang, Yi

    2014-01-01

    RNA isolation is a ubiquitous need, driven by current emphasis on microarrays and miniaturization. With commercial systems requiring 100,000 to 1,000,000 cells for successful isolation, there is a growing need for a small-footprint, easy-to-use device that can harvest nucleic acids from much smaller cell samples (1,000 to 10,000 cells). The process of extraction of RNA from cell cultures is a complex, multi-step one, and requires timed, asynchronous operations with multiple reagents/buffers. An added complexity is the fragility of RNA (subject to degradation) and its reactivity to surface. A novel, microfluidics-based, integrated cartridge has been developed that can fully automate the complex process of RNA isolation (lyse, capture, and elute RNA) from small cell culture samples. On-cartridge cell lysis is achieved using either reagents or high-strength electric fields made possible by the miniaturized format. Traditionally, silica-based, porous-membrane formats have been used for RNA capture, requiring slow perfusion for effective capture. In this design, high efficiency capture/elution are achieved using a microsphere-based "microfluidized" format. Electrokinetic phenomena are harnessed to actively mix microspheres with the cell lysate and capture/elution buffer, providing important advantages in extraction efficiency, processing time, and operational flexibility. Successful RNA isolation was demonstrated using both suspension (HL-60) and adherent (BHK-21) cells. Novel features associated with this development are twofold. First, novel designs that execute needed processes with improved speed and efficiency were developed. These primarily encompass electric-field-driven lysis of cells. The configurations include electrode-containing constructs, or an "electrode-less" chip design, which is easy to fabricate and mitigates fouling at the electrode surface; and the "fluidized" extraction format based on electrokinetically assisted mixing and contacting of microbeads in a shape-optimized chamber. A secondary proprietary feature is in the particular layout integrating these components to perform the desired operation of RNA isolation. Apart from a novel functional capability, advantages of the innovation include reduced or eliminated use of toxic reagents, and operator-independent extraction of RNA.

  13. Everolimus-Eluting Stents in Patients With Bare-Metal and Drug-Eluting In-Stent Restenosis: Results From a Patient-Level Pooled Analysis of the RIBS IV and V Trials.

    PubMed

    Alfonso, Fernando; Pérez-Vizcayno, María José; García Del Blanco, Bruno; García-Touchard, Arturo; López-Mínguez, José-Ramón; Masotti, Mónica; Zueco, Javier; Melgares, Rafael; Mainar, Vicente; Moreno, Raul; Domínguez, Antonio; Sanchís, Juan; Bethencourt, Armando; Moreu, José; Cequier, Angel; Martí, Vicens; Otaegui, Imanol; Bastante, Teresa; Gonzalo, Nieves; Jiménez-Quevedo, Pilar; Cárdenas, Alberto; Fernández, Cristina

    2016-07-01

    Treatment of patients with drug-eluting stent (DES) in-stent restenosis (ISR) is more challenging than that of patients with bare-metal stent ISR. However, the results of everolimus-eluting stents (EES) in these distinct scenarios remain unsettled. A pooled analysis of the RIBS IV (Restenosis Intra-Stent of Drug-Eluting Stents: Paclitaxel-Eluting Balloon vs Everolimus-Eluting Stent) and RIBS V (Restenosis Intra-Stent of Bare Metal Stents: Paclitaxel-Eluting Balloon vs Everolimus-Eluting Stent) randomized trials was performed using patient-level data to compare the efficacy of EES in bare-metal stent ISR and DES-ISR. Inclusion and exclusion criteria were identical in both trials. Results of 94 patients treated with EES for bare-metal stent ISR were compared with those of 155 patients treated with EES for DES-ISR. Baseline characteristics were more adverse in patients with DES-ISR, although they presented later and more frequently with a focal pattern. After intervention, minimal lumen diameter (2.22±0.5 versus 2.38±0.5 mm, P=0.01) was smaller in the DES-ISR group. Late angiographic findings (89.3% of eligible patients), including minimal lumen diameter (2.03±0.7 versus 2.36±0.6 mm, P<0.001) and diameter stenosis (23±22 versus 13±17%, P<0.001) were poorer in patients with DES-ISR. Results were consistent in the in-segment and in-lesion analyses. On multiple linear regression analysis, minimal lumen diameter at follow-up remained significantly smaller in patients with DES-ISR. Finally, at 1-year clinical follow-up (100% of patients), mortality (2.6 versus 0%, P<0.01) and need for target vessel revascularization (8 versus 2%, P=0.03) were higher in the DES-ISR group. This patient-level pooled analysis of the RIBS IV and RIBS V randomized clinical trials suggests that EES provide favorable outcomes in patients with ISR. However, the results of EES are less satisfactory in patients with DES-ISR than in those with bare-metal stent ISR. URL: http://www.clinicaltrials.gov. Unique identifiers: NCT01239953 and NCT01239940. © 2016 American Heart Association, Inc.

  14. The use of FTA cards for preserving unfixed cytological material for high-throughput molecular analysis.

    PubMed

    Saieg, Mauro Ajaj; Geddie, William R; Boerner, Scott L; Liu, Ni; Tsao, Ming; Zhang, Tong; Kamel-Reid, Suzanne; da Cunha Santos, Gilda

    2012-06-25

    Novel high-throughput molecular technologies have made the collection and storage of cells and small tissue specimens a critical issue. The FTA card provides an alternative to cryopreservation for biobanking fresh unfixed cells. The current study compared the quality and integrity of the DNA obtained from 2 types of FTA cards (Classic and Elute) using 2 different extraction protocols ("Classic" and "Elute") and assessed the feasibility of performing multiplex mutational screening using fine-needle aspiration (FNA) biopsy samples. Residual material from 42 FNA biopsies was collected in the cards (21 Classic and 21 Elute cards). DNA was extracted using the Classic protocol for Classic cards and both protocols for Elute cards. Polymerase chain reaction for p53 (1.5 kilobase) and CARD11 (500 base pair) was performed to assess DNA integrity. Successful p53 amplification was achieved in 95.2% of the samples from the Classic cards and in 80.9% of the samples from the Elute cards using the Classic protocol and 28.5% using the Elute protocol (P = .001). All samples (both cards) could be amplified for CARD11. There was no significant difference in the DNA concentration or 260/280 purity ratio when the 2 types of cards were compared. Five samples were also successfully analyzed by multiplex MassARRAY spectrometry, with a mutation in KRAS found in 1 case. High molecular weight DNA was extracted from the cards in sufficient amounts and quality to perform high-throughput multiplex mutation assays. The results of the current study also suggest that FTA Classic cards preserve better DNA integrity for molecular applications compared with the FTA Elute cards. Copyright © 2012 American Cancer Society.

  15. Investigating interactions between phospholipase B-Like 2 and antibodies during Protein A chromatography.

    PubMed

    Tran, Benjamin; Grosskopf, Vanessa; Wang, Xiangdan; Yang, Jihong; Walker, Don; Yu, Christopher; McDonald, Paul

    2016-03-18

    Purification processes for therapeutic antibodies typically exploit multiple and orthogonal chromatography steps in order to remove impurities, such as host-cell proteins. While the majority of host-cell proteins are cleared through purification processes, individual host-cell proteins such as Phospholipase B-like 2 (PLBL2) are more challenging to remove and can persist into the final purification pool even after multiple chromatography steps. With packed-bed chromatography runs using host-cell protein ELISAs and mass spectrometry analysis, we demonstrated that different therapeutic antibodies interact to varying degrees with host-cell proteins in general, and PLBL2 specifically. We then used a high-throughput Protein A chromatography method to further examine the interaction between our antibodies and PLBL2. Our results showed that the co-elution of PLBL2 during Protein A chromatography is highly dependent on the individual antibody and PLBL2 concentration in the chromatographic load. Process parameters such as antibody resin load density and pre-elution wash conditions also influence the levels of PLBL2 in the Protein A eluate. Furthermore, using surface plasmon resonance, we demonstrated that there is a preference for PLBL2 to interact with IgG4 subclass antibodies compared to IgG1 antibodies. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Development of an Analytical Method for Explosive Residues in Soil,

    DTIC Science & Technology

    1987-06-01

    confirm peak identities. The eluent for both columns should be 50:50 methanol-water. The elution time for all the analytes of interest on the LC -18 column...nitrate at 1.77 min for LC -8, 1.73 min for LC -DP, and 1.80 for LC -1. 23 Table A2. Instrument calibration results for HMX. Concentration Solution Soil* Peak ...LCT 12 AUG 2 0 W 1M 2j TNT Owl ""r’ L ,,,O MRYX TN L DNS 2 HMX 0 12 LC -CN 110 KMX S 8 TETRYL 6 RDXW 4 DNB and TNB 0 Approved for public release

  17. Design and performance of an automated radionuclide separator: its application on the determination of ⁹⁹Tc in groundwater.

    PubMed

    Chung, Kun Ho; Choi, Sang Do; Choi, Geun Sik; Kang, Mun Ja

    2013-11-01

    A modular automated radionuclide separator for (99)Tc (MARS Tc-99) has been developed for the rapid and reproducible separation of technetium in groundwater samples. The control software of MARS Tc-99 was developed in the LabView programming language. An automated radiochemical method for separating (99)Tc was developed and validated by the purification of (99m)Tc tracer solution eluted from a commercial (99)Mo/(99m)Tc generator. The chemical recovery and analytical time for this radiochemical method were found to be 96 ± 2% and 81 min, respectively. Copyright © 2013 Elsevier Ltd. All rights reserved.

  18. Ion exchange purification of scandium

    DOEpatents

    Herchenroeder, Laurie A.; Burkholder, Harvey R.

    1990-10-23

    An improvement in purification of scandium through ion exchange chromatography is disclosed in which the oxidation potential of the eluting solution is altered by the addition of potassium chlorate or ammonium chloride so that removal of contaminants is encouraged. The temperature, pH and concentration of the eluent HEDTA are controlled in order to maintain the scandium in the column while minimizing dilution of the scandium band. Recovery of scandium is improved by pumping dilute scandium over the column prior to stripping the scandium and precipitation. This eliminates the HEDTA ion and other monovalent cations contaminating the scandium band. This method maximizes recovery of scandium while maintaining purity.

  19. Ion exchange purification of scandium

    DOEpatents

    Herchenroeder, L.A.; Burkholder, H.R.

    1990-10-23

    An improvement in purification of scandium through ion exchange chromatography is disclosed in which the oxidation potential of the eluting solution is altered by the addition of potassium chlorate or ammonium chloride so that removal of contaminants is encouraged. The temperature, pH and concentration of the eluent HEDTA are controlled in order to maintain the scandium in the column while minimizing dilution of the scandium band. Recovery of scandium is improved by pumping dilute scandium over the column prior to stripping the scandium and precipitation. This eliminates the HEDTA ion and other monovalent cations contaminating the scandium band. This method maximizes recovery of scandium while maintaining purity. 2 figs.

  20. Recovery of transplutonium elements from nuclear reactor waste

    DOEpatents

    Campbell, David O.; Buxton, Samuel R.

    1977-05-24

    A method of separating actinide values from nitric acid waste solutions resulting from reprocessing of irradiated nuclear fuels comprises oxalate precipitation of the major portion of actinide and lanthanide values to provide a trivalent fraction suitable for subsequent actinide/lanthanide partition, exchange of actinide and lanthanide values in the supernate onto a suitable cation exchange resin to provide an intermediate-lived raffinate waste stream substantially free of actinides, and elution of the actinide values from the exchange resin. The eluate is then used to dissolve the trivalent oxalate fraction prior to actinide/lanthanide partition or may be combined with the reprocessing waste stream and recycled.

Top