DOE Office of Scientific and Technical Information (OSTI.GOV)
Tanahashi, Yukichi; Goshima, Satoshi, E-mail: gossy@par.odn.ne.jp; Kondo, Hiroshi
PurposeTo identify predictive factors for embolic material conversion to N-butyl cyanoacrylate (NBCA) for the treatment of primary postpartum hemorrhage (PPH) after failed transcatheter arterial embolization (TAE) using gelatin sponge (GS).Materials and MethodsInstitutional review board approval was obtained. We retrospectively studied 62 consecutive women with primary PPH who underwent TAE between January 2006 and March 2015. Five of them were excluded for the following: cardiopulmonary arrest at arrival (n = 1), uterine inversion (n = 1), and hysterectomy after TAE (n = 3). Remaining 57 women (age range, 21–43 years; mean, 32.6 years) comprised study population. TAE was initially performed using GS in all cases andmore » then converted to NBCA after two embolizations using GS with persistent hemodynamic instability or vaginal bleeding. The patients’ background, uterine height, vital signs, laboratory tests, disseminated intravascular coagulation score, and details of procedure were reviewed. Univariate and multivariate analyses were performed to determine factors related to embolic material conversion.ResultsTechnical success rate was 100%. Fourteen patients (25%) needed embolic material conversion to NBCA. Univariate analysis showed that uterine height, systolic blood pressure (sBP), and hemoglobin level were significantly related to embolic material conversion to NBCA (P = 0.029, 0.030, and 0.042). Logistic regression analysis showed that uterine height (odds ratio, 1.37; P = 0.025) and sBP (odds ratio, 0.96; P = 0.003) were associated with embolic material conversion to NBCA.ConclusionUterine height and sBP can be predictive factors for embolic material conversion to NBCA for the treatment of PPH.Level of EvidenceLevel 4, Case Control Study.« less
Embolization of traumatic and non-traumatic peripheral vascular lesions with Onyx
Regine, Renato; De Siero, Michele; Rescigno, Antonio; Sica, Vincenzo; Cantarela, Raffaele; Villari, Vincenzo
2015-01-01
Purpose The aim of our study is to verify the feasibility and the efficacy of Onyx as embolization agent in the treatment of traumatic and non-traumatic peripheral vascular lesions. Materials and Methods In the period between September 2006 and March 2012, we treated with Onyx 26 patients (14 males/12 females; age range, 18–85 years old; mean age, 65 years old), 11 of which with traumatic peripheral vascular lesions and 15 with non-traumatic vascular lesions (9 neoplastic hemorrhagic lesions, 3 arteriovenous malformations (AVMs) and 3 aneurysms). Follow-up controls were performed with clinical examination and by multidetector computed tomography (MDCT) imaging 1, 6, and 12 months after the procedure. Results All peripheral vascular lesions were embolized with Onyx; 3 patients with aneurysms were treated with Onyx associated with endovascular coils. Four elective and 22 emergency embolization procedures were performed. In all patients, we obtained cessation of bleeding and the complete and permanent embolization of all vascular lesions. Conclusions Onyx is an effective and safe embolization agent for peripheral vascular lesions. PMID:25838923
Puri, Ajit S; Kühn, Anna L; Hou, Samuel Y; Wakhloo, Ajay K
2014-01-01
Onyx is a non-adhesive polymer used for embolization of arteriovenous malformations and dural arteriovenous fistulas (DAVFs). The limiting factor for Onyx embolization is usually the amount of microcatheter reflux, which can be safely tolerated. The dual microcatheter technique, compliant balloon use proximally and the use of the dual lumen Scepter balloon have been described to prevent and limit proximal Onyx reflux. We describe the use the Navien 058 intermediate guide catheter to accept the Onyx reflux in its lumen and possibly also serve as a mechanical barrier to avoid reflux into the anastomotic channel connecting the occipital artery to the vertebral artery during DAVF embolization via the occipital artery. Complete embolization of the DAVF was achieved using the lumen of the Navien catheter to accept aggressive Onyx reflux. Complete cure of the DAVF was obtained with Onyx cast filling the entire venous pouch. Besides providing distal access support, intermediate guide catheters can also prevent embolic material reflux by accepting reflux into the lumen and providing a mechanical barrier.
Puri, Ajit S; Kühn, Anna L; Hou, Samuel Y; Wakhloo, Ajay K
2014-01-01
Summary Onyx is a non-adhesive polymer used for embolization of arteriovenous malformations and dural arteriovenous fistulas (DAVFs). The limiting factor for Onyx embolization is usually the amount of microcatheter reflux, which can be safely tolerated. The dual microcatheter technique, compliant balloon use proximally and the use of the dual lumen Scepter balloon have been described to prevent and limit proximal Onyx reflux. We describe the use the Navien 058 intermediate guide catheter to accept the Onyx reflux in its lumen and possibly also serve as a mechanical barrier to avoid reflux into the anastomotic channel connecting the occipital artery to the vertebral artery during DAVF embolization via the occipital artery. Complete embolization of the DAVF was achieved using the lumen of the Navien catheter to accept aggressive Onyx reflux. Complete cure of the DAVF was obtained with Onyx cast filling the entire venous pouch. Besides providing distal access support, intermediate guide catheters can also prevent embolic material reflux by accepting reflux into the lumen and providing a mechanical barrier. PMID:25207904
Venkatesh, Hosur Ananthashayana; Gamanagatti, Shivanand; Garg, Pramod; Srivastava, Deep Narayan
2016-01-01
Visceral artery pseudoaneurysms occur mostly as a result of inflammation and trauma. Owing to high risk of rupture, they require early treatment to prevent lethal complications. Knowledge of the various approaches of embolization of pseudoaneurysms and different embolic materials used in the management of visceral artery pseudoaneurysms is essential for successful and safe embolization. We review and illustrate the endovascular, percutaneous and endoscopic ultrasound techniques used in the treatment of visceral artery pseudoaneurysm and briefly discuss the embolic materials and their benefits and risks. PMID:27134524
Tacher, Vania; Duran, Rafael; Lin, MingDe; Sohn, Jae Ho; Sharma, Karun V.; Wang, Zhijun; Chapiro, Julius; Gacchina Johnson, Carmen; Bhagat, Nikhil; Dreher, Matthew R.; Schäfer, Dirk; Woods, David L.; Lewis, Andrew L.; Tang, Yiqing; Grass, Michael; Wood, Bradford J.
2016-01-01
Purpose To assess the visibility of radiopaque microspheres during transarterial embolization (TAE) in the VX2 rabbit liver tumor model by using multimodality imaging, including single-snapshot radiography, cone-beam computed tomography (CT), multidetector CT, and micro-CT. Materials and Methods The study was approved by the institutional animal care and use committee. Fifteen VX2-tumor-bearing rabbits were assigned to three groups depending on the type of embolic agent injected: 70–150-μm radiopaque microspheres in saline (radiopaque microsphere group), 70–150-μm radiopaque microspheres in contrast material (radiopaque microsphere plus contrast material group), and 70–150-μm radiolucent microspheres in contrast material (nonradiopaque microsphere plus contrast material group). Rabbits were imaged with single-snapshot radiography, cone-beam CT, and multidetector CT. Three to 5 weeks after sacrifice, excised livers were imaged with micro-CT and histologic analysis was performed. The visibility of the embolic agent was assessed with all modalities before and after embolization by using a qualitative three-point scale score reading study and a quantitative assessment of the signal-to-noise ratio (SNR) change in various regions of interest, including the tumor and its feeding arteries. The Kruskal-Wallis test was used to compare the rabbit characteristics across groups, and the Wilcoxon signed rank test was used to compare SNR measurements before and after embolization. Results Radiopaque microspheres were qualitatively visualized within tumor feeding arteries and targeted tissue with all imaging modalities (P < .05), and their presence was confirmed with histologic examination. SNRs of radiopaque microsphere deposition increased after TAE on multidetector CT, cone-beam CT, and micro-CT images (P < .05). Similar results were obtained when contrast material was added to radiopaque microspheres, except for additional image attenuation due to tumor enhancement. For the group with nonradiopaque microspheres and contrast material, retained tumoral contrast remained qualitatively visible with all modalities except for micro-CT, which demonstrated soluble contrast material washout over time. Conclusion Radiopaque microspheres were visible with all imaging modalities and helped increase conspicuity of the tumor as well as its feeding arteries after TAE in a rabbit VX2 liver tumor model. © RSNA, 2015 PMID:26678453
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vanninen, Ritva L., E-mail: ritva.vanninen@kuh.fi; Manninen, I.
Purpose. To describe our preliminary experience with a new liquid embolization agent, Onyx, in peripheral interventions. Methods and results. We successfully treated two peripheral aneurysms (one in an internal iliac artery, one in a thoracic collateral artery of an aortic coarctation), two peripheral pseudoaneurysms (one in a lumbar artery, one in a renal artery), and one pulmonary arteriovenous malformation. Conclusion. Onyx is a promising alternative embolic material for peripheral interventions. It can be combined with coils in selected cases, and balloon catheters can be effectively used during slow injection of embolic material to control flow and protect the aneurysm neck.
[Embolization as a treatment method in post-traumatic right hepatic artery pseudoaneurysm].
Dobrowolska-Bak, Malgorzata; Brzegowy, Paweł; Urbanik, Andrzej
2012-01-01
A case of 42-year-old man with post-traumatic right hepatic artery pseudoaneurysm successfully treated by endovascular embolization with histoacrylate glue is presented. Despite coils are mostly used embolic material in pseudoaneurysm, embolization with histoacrylate glue can be highly effective and quick treatment modality for post-traumatic hepatic artery pseudoaneurysm, especially in cases when it is impossible to use standard materials.
Vander Mijnsbrugge, Ward; Laleman, Wim; Van Steenbergen, Werner; Heye, Sam; Verslype, Chris; Maleux, Geert
2017-03-01
Background Long-term outcome after embolization of pancreatitis-induced pseudoaneurysm is not yet determined. Purpose To assess the long-term efficacy and patients' overall survival after embolization of pancreatitis-induced pseudoaneurysm. Material and Methods Patients referred for endovascular treatment of a pancreatitis-induced pseudoaneurysm between January 1998 and January 2014 were analyzed. Embolization procedures were performed by transcatheter techniques using different types of embolic agents. Demographic, technical-radiological, and clinical data were collected. Results Thirty-four patients were identified with a pancreatitis-induced pseudoaneurysm; the underlying disease was acute (n = 13; 38%) or chronic (n = 21; 62%) pancreatitis; seven patients (20.6%) had active bleeding when embolized, while in the remaining 27 patients (79.4%) the pseudoaneurysm was not bleeding. In all 34 patients, successful endovascular exclusion of the pseudoaneurysm was obtained after the first attempt. Minor complications occurred in 11 patients (30%); no major complications were noted. A new pseudoaneurysm on a different vessel was identified during follow-up in three patients (9%). In another patient (3%), the excluded pseudoaneurysm reopened during follow-up. All four recurrences occurred within the first 5 months after embolization. Long-term follow-up (mean, 6.6 years; range, 4 months-16 years) revealed estimated survival rates of 94%, 89%, and 75% after 2, 5, and 10 years respectively, without pseudoaneurysm-related death. Conclusion Catheter-directed embolization of pancreatitis-induced pseudoaneurysms is relatively safe and effective. Recurrence or new pseudoaneurysm formation was low and occurred within the first 6 months after embolization. Overall survival is high, with no pseudoaneurysm-related deaths.
Microcatheter Embolization of Intractable Idiopathic Epistaxis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Leppaenen, Martti; Seppaenen, Seppo; Laranne, Jussi
1999-11-15
Purpose: To assess the efficacy and safety of microcatheter embolization in the treatment of intractable idiopathic epistaxis. Methods: Thirty-seven patients underwent microcatheter embolization in 1991-1998. We evaluated retrospectively the technical and clinical outcome, the number of complications, the duration of embolization in each case, and the number of blood transfusions needed. All embolizations were done with biplane digital subtraction angiography (DSA) equipment. The procedure was carried out under local anesthesia using transfemoral catheterization, except in one case where the translumbar route was used. Tracker 18 or 10 microcatheters were advanced as far as possible to the distal branches of themore » sphenopalatine artery. Polyvinyl alcohol (PVA) particles were used for embolization in most cases, while platinum coils or a combination of these two materials were occasionally used. The primary outcome was always assessed immediately by angiography. Follow-up data were obtained from patient records, by interviewing patients on the telephone or by postal questionnaires when necessary. The mean follow-up time was 21 months. Results: The embolization was technically successful in all 37 cases. A curative outcome was achieved in 33 cases (89%). The mean duration of the procedure was 110 min. Four patients (8%) had mild transient complications, but no severe or persistent complications were encountered. Twenty-three patients needed a blood transfusion. Slight rebleeding occurred in three patients during the follow-up; all responded to conservative treatment. One patient suffered two episodes of rebleeding within 2 months after primary embolization. Re-embolizations successfully stopped the bleeding. Conclusion: Embolization is the primary invasive modality for treating intractable idiopathic epistaxis. It proved both safe and effective over a relatively long follow-up.« less
Bartling, Soenke H; Budjan, Johannes; Aviv, Hagit; Haneder, Stefan; Kraenzlin, Bettina; Michaely, Henrik; Margel, Shlomo; Diehl, Steffen; Semmler, Wolfhard; Gretz, Norbert; Schönberg, Stefan O; Sadick, Maliha
2011-03-01
Embolization therapy is gaining importance in the treatment of malignant lesions, and even more in benign lesions. Current embolization materials are not visible in imaging modalities. However, it is assumed that directly visible embolization material may provide several advantages over current embolization agents, ranging from particle shunt and reflux prevention to improved therapy control and follow-up assessment. X-ray- as well as magnetic resonance imaging (MRI)-visible embolization materials have been demonstrated in experiments. In this study, we present an embolization material with the property of being visible in more than one imaging modality, namely MRI and x-ray/computed tomography (CT). Characterization and testing of the substance in animal models was performed. To reduce the chance of adverse reactions and to facilitate clinical approval, materials have been applied that are similar to those that are approved and being used on a routine basis in diagnostic imaging. Therefore, x-ray-visible Iodine was combined with MRI-visible Iron (Fe3O4) in a macroparticle (diameter, 40-200 μm). Its core, consisting of a copolymerized monomer MAOETIB (2-methacryloyloxyethyl [2,3,5-triiodobenzoate]), was coated with ultra-small paramagnetic iron oxide nanoparticles (150 nm). After in vitro testing, including signal to noise measurements in CT and MRI (n = 5), its ability to embolize tissue was tested in an established tumor embolization model in rabbits (n = 6). Digital subtraction angiography (DSA) (Integris, Philips), CT (Definition, Siemens Healthcare Section, Forchheim, Germany), and MRI (3 Tesla Magnetom Tim Trio MRI, Siemens Healthcare Section, Forchheim, Germany) were performed before, during, and after embolization. Imaging signal changes that could be attributed to embolization particles were assessed by visual inspection and rated on an ordinal scale by 3 radiologists, from 1 to 3. Histologic analysis of organs was performed. Particles provided a sufficient image contrast on DSA, CT (signal to noise [SNR], 13 ± 2.5), and MRI (SNR, 35 ± 1) in in vitro scans. Successful embolization of renal tissue was confirmed by catheter angiography, revealing at least partial perfusion stop in all kidneys. Signal changes that were attributed to particles residing within the kidney were found in all cases in all the 3 imaging modalities. Localization distribution of particles corresponded well in all imaging modalities. Dynamic imaging during embolization provided real-time monitoring of the inflow of embolization particles within DSA, CT, and MRI. Histologic visualization of the residing particles as well as associated thrombosis in renal arteries could be performed. Visual assessment of the likelihood of embolization particle presence received full rating scores (153/153) after embolization. Multimodal-visible embolization particles have been developed, characterized, and tested in vivo in an animal model. Their implementation in clinical radiology may provide optimization of embolization procedures with regard to prevention of particle misplacement and direct intraprocedural visualization, at the same time improving follow-up examinations by utilizing the complementary characteristics of CT and MRI. Radiation dose savings can also be considered. All these advantages could contribute to future refinements and improvements in embolization therapy. Additionally, new approaches in embolization research may open up.
Tolly, Brian T; Kosky, Jenna L; Koht, Antoun; Hemmer, Laura B
2017-02-15
A healthy 26-year-old man with cerebral arteriovenous malformation underwent staged endovascular embolization with Onyx followed by awake craniotomy for resection. The perioperative course was complicated by tachycardia and severe intraoperative hypoxemia requiring significant oxygen supplementation. Postoperative chest computed tomography (CT) revealed hyperattenuating Onyx embolization material within the pulmonary vasculature, and an electrocardiogram indicated possible right heart strain, supporting clinically significant embolism. With awake arteriovenous malformation resection following adjunctive Onyx embolization becoming increasingly employed for lesions involving the eloquent cortex, anesthesiologists need to be aware of pulmonary migration of Onyx material as a potential contributor to significant perioperative hypoxemia.
Double Coaxial Microcatheter Technique for Glue Embolization of Renal Arteriovenous Malformations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Uchikawa, Yoko, E-mail: jauchikawa@gmail.com; Mori, Kensaku, E-mail: moriken@md.tsukuba.ac.jp; Shiigai, Masanari, E-mail: m-41gai@yahoo.co.jp
PurposeTo demonstrate the technical benefit of the double coaxial microcatheter technique for embolization of renal arteriovenous malformations (AVMs) with n-butyl cyanoacrylate and iodized oil (glue).Materials and MethodsSix consecutive patients (1 man and 5 women; mean age 61 years; range 44–77 years) with renal AVMs were included. Five patients had hematuria, and one had a risk of heart failure due to a large intrarenal arteriovenous shunt. All patients underwent transarterial embolization using glue and the double coaxial microcatheter technique with outer 2.6F and inner 1.9F microcatheters. After glue injection, the inner microcatheter was retracted, while the outer microcatheter was retained. We assessed themore » complications and clinical outcomes of this technique.ResultsTechnical success was achieved in all patients. In 9 sessions, 34 feeding arteries were embolized with glue using the double coaxial microcatheter technique, 1 was embolized with glue using a single microcatheter, and 2 were embolized with coils. The double coaxial microcatheter technique was useful for selecting small tortuous feeding arteries, preventing glue reflux to the proximal arteries, and approaching multiple feeding arteries without complete retraction of the microcatheters. As a minor complication, glue migrated into the venous system in four patients without any sequelae. In all patients, favorable clinical outcomes, including hematuria cessation in five patients and improvement of the large intrarenal arteriovenous shunt in one patient, were obtained without deterioration of renal function.ConclusionGlue embolization with the double coaxial microcatheter technique was useful for treating renal AVMs with multiple tortuous feeding arteries.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Galván de la Cruz, Olga Olinca; Lárraga-Gutiérrez, José Manuel, E-mail: jlarraga@innn.edu.mx; Laboratorio de Física Médica, Instituto Nacional de Neurología y Neurocirugía
2013-07-01
It is reported in the literature that the material used in an embolization of an arteriovenous malformation (AVM) can attenuate the radiation beams used in stereotactic radiosurgery (SRS) up to 10% to 15%. The purpose of this work is to assess the dosimetric impact of this attenuating material in the SRS treatment of embolized AVMs, using Monte Carlo simulations assuming clinical conditions. A commercial Monte Carlo dose calculation engine was used to recalculate the dose distribution of 20 AVMs previously planned with a pencil beam dose calculation algorithm. Dose distributions were compared using the following metrics: average, minimal and maximummore » dose of AVM, and 2D gamma index. The effect in the obliteration rate was investigated using radiobiological models. It was found that the dosimetric impact of the embolization material is less than 1.0 Gy in the prescription dose to the AVM for the 20 cases studied. The impact in the obliteration rate is less than 4.0%. There is reported evidence in the literature that embolized AVMs treated with SRS have low obliteration rates. This work shows that there are dosimetric implications that should be considered in the final treatment decisions for embolized AVMs.« less
Poyraz, Necdet; Balasar, Mehmet; Gökmen, İbrahim Erdem; Koç, Osman; Aydın, Arif; Göger, Yunus Emre; Öztürk, Ahmet
2017-01-01
Introduction Percutaneous nephrolithotomy (PNL) is the preferred procedure for safe and effective surgical treatment of kidney stones. Hemorrhage is the most serious complication of PNL, resulting from pseudoaneurysm (PA) or arteriovenous fistula (AVF), and can usually be controlled with conservative treatment. Aim To evaluate endovascular treatments and outcomes of vascular complications observed after PNL. Material and methods We retrospectively reviewed data on 19 patients who underwent renal embolization due to post-PNL renal artery bleeding between March 2005 and September 2016. Embolization materials included embolization coils and glue. The incidence of post-PNL vascular complications and their endovascular treatments, outcomes, and the follow-up data were analyzed. Results Nineteen (1.1%) of 1,609 patients (mean age: 44.9 years, range: 19–75 years) underwent angiography and subsequent transcatheter embolization to control bleeding. The mean time to onset of hemorrhage was 7.2 days after PNL (range: 3–18 days). The PNL entry site was the lower calyx in 15 patients, the middle calyx in 3, and the upper calyx in 1. PA, AVF, and PA plus AVF occurred in 14, 5, and 3 of the 19 renal angiography patients, respectively. Embolization of the affected vessels was successful in all 19 patients. The embolization materials of coil, glue, and coil plus glue were used in 16, 3, and 2 patients, respectively. Conclusions Severe hematuria is a rare complication of PNL and can be successfully treated with transcatheter embolization. PMID:29362656
Balloon-Occluded Retrograde Transvenous Embolization of a Pelvic Arteriovenous Malformation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mitsuzaki, Katsuhiko; Yamashita, Yasuyuki; Utsunomiya, Daisuke
1999-11-15
We successfully performed embolization therapy for a pelvic arteriovenous malformation by the retrograde transvenous approach using a liquid embolic material. This malformation was unique in that it had a single draining vein, which allowed this technique employing an occlusion balloon.
Shin, Hong Kyung; Suh, Dae Chul; Jeon, Sang Ryong
2015-05-01
Spinal arteriovenous fistula (AVF) is treated by embolization or surgery. However, transarterial embolization or surgery is difficult in rare cases when the fistula site is very complicated to access especially as in fistular nidus supplied by posterior and anterior spinal artery. We present the case which was treated with intraoperative direct puncture and embolization (IOPE) using glue material, since the usual transarterial or transvenous neurointerventional approach was difficult to embolize the AVF. A 36-year-old woman presented with progressive leg weakness and pain after a 20-year history of lower back pain. She had pelvic and spinal AVF combined with arteriovenous malformation (AVM). Despite prior treatment of the pelvic lesion with radiotherapy and coil embolization, the spinal lesion persisted and caused repeated subarachnoid hemorrhages. A spinal angiogram revealed a tortuous and long feeder of the AVF which had growing venous sac, as well as AVM. Two embolization trials failed because of the long tortuosity and associated anterior spinal artery. Four months later, drastic leg weakness and pain occurred, and IOPE was performed using a glue material. The subsequent recovery of the patient was rapid. One month later, the use of a strong opioid could be discontinued, and the patient could walk with aid. A follow-up spinal angiogram revealed that the venous sac of the AVF had disappeared. In spinal AVF which is not feasible to access by usual intervention approach and to dissect surgically, IOPE with glue material can be considered for the treatment.
Rangel-Castilla, Leonardo; Shah, Ankit H; Klucznik, Richard Paul; Diaz, Orlando M
2014-01-01
Preoperative embolization of head, neck, and spinal tumors is frequently used to control tumor bleeding, reduce operative time, and achieve better resection. Numerous embolic materials have been used. The use of the liquid embolic agent Onyx is rapidly increasing but current experience is limited to small case series. Our purpose was to evaluate the indications, techniques, angiographic devascularization, blood loss, outcome, and general efficacy of preoperative tumor embolization with Onyx in a large series. Retrospective analysis of 100 consecutive cases of head, neck, and spinal tumors embolized with Onyx and prospective follow-up. 100 patients (63 women, 37 men) were included. Tumors included 39 meningiomas, 23 metastases, 16 parangliomas, five juvenile nasal angiofibromas, five giant cell bone tumors, three Ewing's sarcomas, three hemangiomas, three hemangioblastomas, two multiple myelomas, and one osteoblastoma. In all patients, angiographic analysis of the feeding arteries and branches was performed and all embolizations were completed in a single session. Additional materials were used in 28 patients. No mortality or major complications were observed. Minor complications were seen in 11 patients. 85 patients underwent surgery; 79 within the next 48 h and six of them 4-188 days after embolization. Embolization of intracranial, head, neck, and spinal tumors with Onyx is effective and safe by a transarterial route or by direct puncture. Onyx penetrates well into the tumor capillary with less arterial catheterization. Studies are necessary to establish long term utility in adjunct or palliative tumor embolization.
Jubeli, E; Yagoubi, N; Pascale, F; Bédouet, L; Slimani, K; Labarre, D; Saint-Maurice, J P; Laurent, A; Moine, L
2015-10-01
A polymer based material was developed to act as an embolic agent and drug reservoir for the treatment of arteriovenous malformations (AVM) and hyper vascularized solid tumors. The aim was to combine the blocking of blood supply to the target region and the inhibition of the embolization-stimulated angiogenesis. The material is composed of an ethanolic solution of a linear acrylate based copolymer and acrylate calibrated microparticles containing nanospheres loaded with sunitinib, an anti-angiogenic agent. The precipitation of the linear copolymer in aqueous environment after injection through microcatheter results in the formation of an in-situ embolization gel whereas the microparticles serve to increase the cohesive properties of the embolization agent and to form a reservoir from which the sunitinib-loaded nanospheres are released post-embolization. The swollen state of the microparticles in contact with aqueous medium results in the release of the nanospheres out of microparticles macromolecular structure. After the synthesis, the formulation and the characterization of the different components of the material, anti-angiogenic activity was evaluated in vitro using endothelial cells and in vivo using corneal neovascularization model in rabbit. The efficiency of the arterial embolization was tested in vivo in a sheep model. Results proved the feasibility of this new system for vascular embolization in association with an in situ delivery of anti-angiogenic drug. This combination is a promising strategy for the management of arteriovenous malformations and solid tumors. Copyright © 2015 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dohan, Anthony, E-mail: anthony.dohan@lrb.aphp.fr; Soyer, Philippe, E-mail: philippe.soyer@lrb.aphp.fr; Subhani, Aqeel, E-mail: drsubhani07@gmail.com
Objective: This study was designed to determine the incidence of arterial pseudoaneurysm in patients presenting with postpartum hemorrhage (PPH), to analyze the angiographic characteristics of pseudoaneurysms that cause PPH, and to evaluate the effectiveness of pelvic arterial embolization for the treatment of this condition.Study designEighteen women with pelvic arterial pseudoaneurysm were retrieved from a series of 588 consecutive patients with PPH treated by arterial embolization. Clinical files, angiographic examinations, and procedure details were reviewed. Results: The incidence of pseudoaneurysm was 3.06 % (18/588; 95 % confidence interval (CI): 1.82-4.8 %). A total of 20 pseudoaneurysms were found; 15/20 (75 %)more » were located on the uterine arteries. Angiography revealed extravasation of contrast material from pseudoaneurysm indicating rupture in 9 of 18 (50 %) patients. Arterial embolization was performed using gelatin sponge alone in 12 of 18 (67 %) patients or in association with metallic coils in 5 of 18 (28 %) patients or n-butyl-2-cyanoacrylate in 1 of 18 (6 %) patients. Arterial embolization allowed controlling the bleeding in all patients after one or two embolization sessions in 17 of 18 (94 %) and 1 of 18 patients (6 %) respectively, without complications, obviating the need for further surgery. Conclusions: Pseudoaneurysm is rarely associated with PPH. Arterial embolization is an effective and safe procedure for the treatment of PPH due to uterine or vaginal artery pseudoaneurysm. Our results suggest that gelatin sponge is effective for the treatment of ruptured pseudoaneurysms, although we agree that our series does not contain sufficient material to allow drawing definitive conclusions with respect to the most effective embolic material.« less
Embolization Materials Made of Gelatin: Comparison Between Gelpart and Gelatin Microspheres
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ohta, Shinichi, E-mail: junryuhei@belle.shiga-med.ac.jp; Nitta, Norihisa; Sonoda, Akinaga
2010-02-15
Purpose:The object of this study was to assess the level of embolization in the embolized artery and the degradation period of these two embolic agents in the renal arteries using rabbit models.Materials and Methods: The renal artery was embolized using 5 mg of gelatin microspheres (GMSs; diameter, 35-100 {mu}m; group 1) or 1 mg of Gelpart (diameter, 1 mm; group 2). For each group, angiographies were performed on two kidneys immediately after the embolic procedure and on days 3, 7, and 14 after embolization. This was followed by histopathological examinations of the kidneys.Results:Follow-up angiograms on each day revealed the persistencemore » of poorly enhanced wedge-shaped areas in the parenchymal phase in all cases. In group 1, four of six cases showed poorly enhanced small areas in the follow-up angiograms. In group 2, all cases showed poorly enhanced large areas. In the histopathological specimens, it was observed that immediately after embolization, the particles reached the interlobular arteries in group 1 and the interlobar arteries in group 2. In all cases in group 1, the particles were histologically identified even on day 14. In one case in group 2 on day 14, the particles were not identified.Conclusion:In conclusion, although GMSs and Gelpart were similar in the point of gelatin particles, the level of embolization and the degradation period were different between GMSs and Gelpart.« less
Poyraz, Necdet; Balasar, Mehmet; Gökmen, İbrahim Erdem; Koç, Osman; Sönmez, Mehmet Giray; Aydın, Arif; Göger, Yunus Emre; Öztürk, Ahmet
2017-12-01
Percutaneous nephrolithotomy (PNL) is the preferred procedure for safe and effective surgical treatment of kidney stones. Hemorrhage is the most serious complication of PNL, resulting from pseudoaneurysm (PA) or arteriovenous fistula (AVF), and can usually be controlled with conservative treatment. To evaluate endovascular treatments and outcomes of vascular complications observed after PNL. We retrospectively reviewed data on 19 patients who underwent renal embolization due to post-PNL renal artery bleeding between March 2005 and September 2016. Embolization materials included embolization coils and glue. The incidence of post-PNL vascular complications and their endovascular treatments, outcomes, and the follow-up data were analyzed. Nineteen (1.1%) of 1,609 patients (mean age: 44.9 years, range: 19-75 years) underwent angiography and subsequent transcatheter embolization to control bleeding. The mean time to onset of hemorrhage was 7.2 days after PNL (range: 3-18 days). The PNL entry site was the lower calyx in 15 patients, the middle calyx in 3, and the upper calyx in 1. PA, AVF, and PA plus AVF occurred in 14, 5, and 3 of the 19 renal angiography patients, respectively. Embolization of the affected vessels was successful in all 19 patients. The embolization materials of coil, glue, and coil plus glue were used in 16, 3, and 2 patients, respectively. Severe hematuria is a rare complication of PNL and can be successfully treated with transcatheter embolization.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Basile, Antonio; Rand, Thomas; Lomoschitz, Fritz
2004-09-15
The aim of this study was to compare the efficacy of trisacryl gelatin microspheres versus polyvinyl alcohol particles (PVA) in the preoperative embolization of bone neoplasms, on the basis of intraoperative blood loss quantified by the differences in preoperative and postoperative hematic levels of hemoglobin, hematocrit and erythrocytes count. From January 1997 to December 2002, preoperative embolization of bone tumors (either primary or secondary) was carried out in 49 patients (age range 12/78), 20 of whom were treated with trysacril gelatin microspheres (group A) and 29 with PVA particles (group B). The delay between embolization and surgery ranged from 1more » to 13 days in group A and 1 to 4 days in group B. As used in international protocols, we considered hematic levels of hemoglobin, hematocrit and erythrocytes count for the measurement of intraoperative blood loss then the differences in pre- and postoperative levels were used as statistical comparative parameters. We compared the values of patients treated with embospheres (n = 10) and PVA (n = 18) alone, and patients treated with (group A = 10; group B = 11) versus patients treated without other additional embolic materials in each group (group A = 10; group B = 18). According to the Student's t-test (p < 0.05), the difference of hematic parameters between patients treated by embospheres and PVA alone were significant; otherwise there was no significant difference between patients treated with only one embolic material (embospheres and PVA) versus those treated with other additional embolic agents in each group. The patients treated with microspheres had a minor quantification of intraoperative blood loss compared to those who received PVA particles. Furthermore, they had a minor increase of bleeding related to the delay time between embolization and surgery. The use of additional embolic material did not improve the efficacy of the procedure in either group of patients.« less
Managing vulvovaginal hematoma by arterial embolization as first-line hemostatic therapy.
Takagi, Kenjiro; Akashi, Keiko; Horiuchi, Isao; Nakamura, Eishin; Samejima, Koki; Ushijima, Junko; Okochi, Tomohisa; Hamamoto, Kohei; Tanno, Keisuke
2017-04-01
A puerperal vulvovaginal hematoma may continue to grow after a surgical procedure and may require blood transfusion. Thus, we selected arterial embolization for hemostasis as the first-line management in two cases of large vulvovaginal hematoma. Case 1 was a 32-year-old pregnant woman. After delivery, a 10-cm vulvar hematoma developed. An enhanced computed tomography (CT) scan revealed active bleeding. Arterial embolization was performed and complete hemostasis was obtained. Case 2 was a 34-year-old woman with a recurring hematoma after delivery. An enhanced CT scan revealed extravasation in the hematoma. Gelatin sponges were applied and complete hemostasis was obtained. In both cases, arterial embolization was successful without requiring blood transfusions. We successfully managed two cases of puerperal vulvovaginal hematoma by arterial embolization based on the evaluation of an enhanced CT scan. In conclusion, we suggest arterial embolization to be a viable option for first-line treatment in the management of vulvovaginal hematomas. Copyright © 2017. Published by Elsevier B.V.
Jin, Hengwei; Liu, Zhan; Chang, Qing; Chen, Chang; Ge, Huijian; Lv, Xianli; Li, Youxiang
2017-10-01
Objective Brainstem arteriovenous malformations (AVMs) are rare lesions with a high risk of intracranial hemorrhage and are challenging to treat. We present our experience of endovascular embolization with Onyx in these aggressive lesions. Materials and methods Between 2007 and 2016, 13 patients with brainstem AVMs were embolized with Onyx at our center. Twelve patients presented with intracranial hemorrhage and one with headache. Retrospective examinations of patient demographics, clinical presentation, angiographic features, treatment modalities, postoperative complications and outcomes were carried out. Results The AVMs were in the midbrain in 10 patients (one anterior and nine posterior or dorsal), in the posterior pons in two and pontomedullary in one. Complete occlusion was achieved in three patients. Gamma knife radiosurgery was performed in six patients who were near-completely or partially embolized. Postoperative complications, including five cases of ischemia and one case of hemorrhage, resulted in four cases of neurological deterioration and two deaths. Clinical follow-up was obtained in 10 patients at a mean period of 45.2 months (range 3 to 93 months). During the follow-up, good clinical outcomes were observed in seven patients with posterior or dorsal midbrain AVMs, and one patient with a posterior pons AVM that was partially occluded died of intracranial hemorrhage. Conclusion Endovascular embolization for brainstem AVM with Onyx is a technical challenge and the reflux of Onyx may cause severe complications. Individualized treatment is needed based on the specific subtype of brainstem AVM.
Computational modelling for the embolization of brain arteriovenous malformations.
Orlowski, Piotr; Summers, Paul; Noble, J Alison; Byrne, James; Ventikos, Yiannis
2012-09-01
Treatment of arteriovenous malformations (AVMs) of the brain often requires the injection of a liquid embolic material to reduce blood flow through the malformation. The type of the liquid and the location of injection have to be carefully planned in a pre-operative manner. We introduce a new model of the interaction of liquid embolic materials with blood for the simulation of their propagation and solidification in the AVM. Solidification is mimicked by an increase of the material's viscosity. Propagation is modelled by using the concept of two-fluids modelling and that of scalar transport. The method is tested on digital phantoms and on one anatomically derived patient AVM case. Simulations showed that intuitive behaviour of the two-fluid system can be confirmed and that two types of glue propagation through the malformation can be reproduced. Distinction between the two types of propagation could be used to identify fistulous and plexiform compartments composing the AVM and to characterize the solidification of the embolic material in them. Copyright © 2011 IPEM. Published by Elsevier Ltd. All rights reserved.
Yuki, I; Kambayashi, Y; Ikemura, A; Abe, Y; Kan, I; Mohamed, A; Dahmani, C; Suzuki, T; Ishibashi, T; Takao, H; Urashima, M; Murayama, Y
2016-02-01
Combination of high-resolution C-arm CT and novel metal artifact reduction software may contribute to the assessment of aneurysms treated with stent-assisted coil embolization. This study aimed to evaluate the efficacy of a novel Metal Artifact Reduction prototype software combined with the currently available high spatial-resolution C-arm CT prototype implementation by using an experimental aneurysm model treated with stent-assisted coil embolization. Eight experimental aneurysms were created in 6 swine. Coil embolization of each aneurysm was performed by using a stent-assisted technique. High-resolution C-arm CT with intra-arterial contrast injection was performed immediately after the treatment. The obtained images were processed with Metal Artifact Reduction. Five neurointerventional specialists reviewed the image quality before and after Metal Artifact Reduction. Observational and quantitative analyses (via image analysis software) were performed. Every aneurysm was successfully created and treated with stent-assisted coil embolization. Before Metal Artifact Reduction, coil loops protruding through the stent lumen were not visualized due to the prominent metal artifacts produced by the coils. These became visible after Metal Artifact Reduction processing. Contrast filling in the residual aneurysm was also visualized after Metal Artifact Reduction in every aneurysm. Both the observational (P < .0001) and quantitative (P < .001) analyses showed significant reduction of the metal artifacts after application of the Metal Artifact Reduction prototype software. The combination of high-resolution C-arm CT and Metal Artifact Reduction enables differentiation of the coil mass, stent, and contrast material on the same image by significantly reducing the metal artifacts produced by the platinum coils. This novel image technique may improve the assessment of aneurysms treated with stent-assisted coil embolization. © 2016 by American Journal of Neuroradiology.
Renal Angiomyolipoma: Mid- to Long-Term Results Following Embolization with Onyx
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thulasidasan, Narayanan, E-mail: narayanant@doctors.net.uk; Sriskandakumar, Srividhiya; Ilyas, Shahzad
PurposePercutaneous transcatheter embolization is currently the preferred treatment for ruptured or enlarging renal angiomyolipoma (AML), although the optimum choice of embolic material has not yet been established. We present mid- to long-term outcomes following embolization of AMLs with Onyx.Materials and MethodsTen AMLs in seven patients (including two with tuberous sclerosis) were embolized with Onyx. Patients were followed-up clinically, with tumour size and renal function measured pre- and post-procedure.ResultsMean pre-treatment AML size was 63.4 mm (range 42–100). Mean clinical follow-up was 431.4 days (range 153–986) and imaging follow-up 284.2 days (range 30–741). There was no haemorrhage from treated lesions within the follow-up period. Ofmore » patients who had cross-sectional imaging pre- and post-procedure, mean decrease in AML size of 22 mm was seen after Onyx embolization (p = 0.0058, 95 % CI 9.13–34.87). No significant difference between serum creatinine was seen pre- and post-procedure (p = 0.54, 95 % CI 8.63–4.85).ConclusionsOnyx embolization of renal AMLs is effective in the medium to long term, with theoretical benefits in safety and durability of result.« less
Hira, A.; Chao, K.
2011-01-01
Summary Percutaneous injection of embolization material within head and neck tumors is being described as an alternative or adjunct to transarterial embolization. Access in these reports is by computed tomography (CT) guidance, which is cumbersome given the need to transport the patient from the CT scanner to angiography suite. We describe a case of direct percutaneous onyx embolization of juvenile nasal angiofibroma following endoscopic access in the angiography suite including self-sustained onyx combustion during surgical electrocautery. PMID:22192553
Ogawa, Yukihisa; Nishimaki, Hiroshi; Osuga, Keigo; Ikeda, Osamu; Hongo, Norio; Iwakoshi, Shinichi; Kawasaki, Ryota; Woodhams, Reiko; Yamaguchi, Masato; Kamiya, Mika; Kanematsu, Masayuki; Honda, Masanori; Kaminou, Toshio; Koizumi, Jun; Kichikawa, Kimihiko
2016-08-01
To investigate the current status of interventional radiology (IR) procedures for a type II endoleak (T2EL) in Japan, and to identify the technical aspects that affect treatment results. A retrospective survey was conducted by distributing questionnaires to 25 institutions. The eligibility criteria were endovascular aortic repair (EVAR) performed using commercial stent grafts and IR performed for T2EL between January 2007 and December 2013. Technical success was defined as disappearance of the EL on digital subtraction angiography immediately after embolization, and imaging success was defined as no EL on contrast-enhanced computed tomography within 6 months. Statistical comparisons of the number of involved branches, embolization level, embolic material, and changes in aneurysm size were made between the imaging success and imaging failure groups. The technical and imaging success rates were also compared between the initial therapy and repeat groups. A total of 166 cases were investigated. Initial therapy was performed in 147 cases (88.6 %), with repeat therapy in 19 cases (11.4 %). Transcatheter arterial embolization (TAE) was used most frequently, in 161 cases (97 %), with direct puncture (DP) used in 5 cases (3 %). Both coil embolization for the branches and NBCA embolization for the sac were frequently chosen. The technical success rate was 83.2 % (TAE group), and the imaging success rate was 46.5 % (TAE + DP groups). Branch + sac embolization was performed more frequently in the imaging success group. There was no significant difference in the number of involved branches or embolic material between the imaging success and imaging failure groups. Enlargement of the aneurysm was more frequently seen in the imaging failure group. There were no significant differences in the technical success and imaging success rates between the initial therapy and repeat groups. This is the first report of a multi-institutional questionnaire survey of IR procedures for T2EL after EVAR in Japan that was conducted to determine the current status. Enlargement of aneurysm size after embolization was more frequently seen in the imaging failure group. It is important to embolize both branch and sac to achieve imaging success, regardless of embolic material. Long-term outcomes need to be investigated.
Suture Embolism of the Left Superior Lobar Pulmonary Artery.
Ahn, Janice Seulgy; Grise, Joy; DelTondo, Joseph A
2018-05-31
Endogenous pulmonary thromboemboli are a common cause of noncardiac sudden natural death. Embolism of exogenous material is a rare but potential finding in autopsies following surgeries, medical procedures, penetrating trauma, and nonparenteral drug abuse. This report describes the first case of a suture embolism of the left superior lobar pulmonary artery following complicated abdominal surgery. © 2018 American Academy of Forensic Sciences.
Dosimetric measurements of Onyx embolization material for stereotactic radiosurgery
DOE Office of Scientific and Technical Information (OSTI.GOV)
Roberts, Donald A.; Balter, James M.; Chaudhary, Neeraj
2012-11-15
Purpose: Arteriovenous malformations are often treated with a combination of embolization and stereotactic radiosurgery. Concern has been expressed in the past regarding the dosimetric properties of materials used in embolization and the effects that the introduction of these materials into the brain may have on the quality of the radiosurgery plan. To quantify these effects, the authors have taken large volumes of Onyx 34 and Onyx 18 (ethylene-vinyl alcohol copolymer doped with tantalum) and measured the attenuation and interface effects of these embolization materials. Methods: The manufacturer provided large cured volumes ({approx}28 cc) of both Onyx materials. These samples weremore » 8.5 cm in diameter with a nominal thickness of 5 mm. The samples were placed on a block tray above a stack of solid water with an Attix chamber at a depth of 5 cm within the stack. The Attix chamber was used to measure the attenuation. These measurements were made for both 6 and 16 MV beams. Placing the sample directly on the solid water stack and varying the thickness of solid water between the sample and the Attix chamber measured the interface effects. The computed tomography (CT) numbers for bulk material were measured in a phantom using a wide bore CT scanner. Results: The transmission through the Onyx materials relative to solid water was approximately 98% and 97% for 16 and 6 MV beams, respectively. The interface effect shows an enhancement of approximately 2% and 1% downstream for 16 and 6 MV beams. CT numbers of approximately 2600-3000 were measured for both materials, which corresponded to an apparent relative electron density (RED) {rho}{sub e}{sup w} to water of approximately 2.7-2.9 if calculated from the commissioning data of the CT scanner. Conclusions: We performed direct measurements of attenuation and interface effects of Onyx 34 and Onyx 18 embolization materials with large samples. The introduction of embolization materials affects the dose distribution of a MV therapeutic beam, but should be of negligible consequence for effective thicknesses of less than 8 mm. The measured interface effects are also small, particularly at 6 MV. Large areas of high-density artifacts and low-density artifacts can cause errors in dose calculations and need to be identified and resolved during planning.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Jae Min; Kim, Man-Deuk, E-mail: mdkim@yuhs.ac; Han, Kichang
PurposeTo evaluate the effect of bariatric arterial embolization (BAE) with non-spherical polyvinyl alcohol (PVA) particles on systemic ghrelin levels, weight change, and gastric ulceration risk in a swine model.Materials and MethodsFrom March 2014 to February 2015, ten healthy swine were used in the study (mean weight 31.5 kg; range 24.0–41.5 kg). The animals were randomly assigned to two groups: the embolized group (n = 5) in which BAE was performed and the control group (n = 5). In the embolized group, BAE was performed by selectively infusing 150–250 or 50–150 μm PVA into the gastric arteries that supplied the fundus of the stomach. In the control group,more » a sham procedure was performed with saline infusion. Plasma ghrelin levels were prospectively obtained at baseline and every 2 weeks thereafter. Endoscopy was performed 3 weeks after BAE to see whether any gastric ulcer occurred. To determine the durability of the occluded arteries, repeated celiac trunk angiography was performed 8 weeks after BAE. Then, all the swine were killed and necropsies were performed.ResultsThe mean post-procedure ghrelin value decreased by 370.0 pg/mL in the embolized group at week 3 (mean 536.0 ± 334.3 pg/mL) and week 5 (mean 515.0 ± 150.0 pg/mL, p < 0.05) relative to baseline (880.0 ± 559.5 pg/mL), respectively, but ghrelin levels were not significantly decreased between the embolized and control groups. There was a significant body weight change as follows: 35.1 ± 9.5 to 46.6 ± 15.7 kg and 31.8 ± 5.8 to 41.2 ± 6.6 kg at baseline and endpoint in the control and embolized groups, respectively (p < 0.05). However, the difference between groups was not significant at endpoint. In the embolized group, ulcerations were identified in three animals (60%) and the recanalization of the embolized arteries was noted on follow-up angiography in three animals (60%), respectively.ConclusionBAE with PVA particles can transiently suppress ghrelin levels in embolized animals, but levels are not significantly different compared to controls. Stomach ulcerations were identified in 60% of the embolized animals.« less
Ko, Gi-Young; Kwon, Young Baek; Yoon, Hyun-Ki; Sung, Kyu-Bo
2018-01-01
Objective To investigate the technical and clinical outcomes of plug-assisted retrograde transvenous obliteration (PARTO) for the treatment of gastric varices (GV) and to evaluate the role of intra-procedural cone-beam computed tomography (CBCT) performed during PARTO to confirm its technical success. Materials and Methods From January 2016 to December 2016, 17 patients with GV who had undergone PARTO were retrospectively evaluated. When the proximal part of the afferent vein was identified on a fluoroscopy, non-contrast CBCT images were obtained. In patients with incomplete embolization of GV, an additional injection of gelatin sponges was performed. Follow-up data from contrast-enhanced CT and upper intestinal endoscopy, as well as clinical and laboratory data were collected. Results Plug-assisted retrograde transvenous obliteration procedures were technically successful in all 17 patients. Complete embolization of GV was detected on CBCT images in 15 patients; whereas, incomplete embolization was detected in two. Complete embolization of GV was then achieved after an additional injection of gelatin sponges in these two patients as demonstrated on the 2nd CBCT image. The mean follow-up period after PARTO was 193 days (range, 73–383 days). A follow-up CT obtained 2–4 months after PARTO demonstrated marked shrinkage or complete obliteration of GV and portosystemic shunts in all 17 patients. There were no cases of variceal bleeding during the follow-up. Conclusion Plug-assisted retrograde transvenous obliteration is technically and clinically effective for the treatment of GV. In addition, intra-procedural CBCT can be an adjunct tool to fluoroscopy, because it can provide an immediate and accurate evaluation of the technical success of PARTO. PMID:29520179
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tsoumakidou, Georgia, E-mail: gtsoumakidou@yahoo.com; Theocharis, Stamatis, E-mail: theocharis@ath.forthnet.gr; Ptohis, Nikolaos, E-mail: nikptohis@yahoo.gr
2011-10-15
Purpose: Percutaneous portal vein embolization (PPVE) induces hypertrophy of the future liver remnant before hepatic resection. The ideal embolic material has not yet been determined. We compared N-butyl-2-cyanocrylate (NBCA) with sodium acrylate-vinyl alcohol copolymer particles using a swine model. Materials and Methods: Twelve pigs underwent PPVE. Six pigs (group A) were embolized with NBCA, and 6 pigs (group B) were embolized with sodium acrylate-vinyl alcohol copolymer particles. Computed tomographic volumetry of the embolized lobe (EL) and the nonembolized lobe (NEL), along with liver function tests, was performed before and at 14 and 28 days after embolization. Tissue samples from bothmore » lobes were taken 14 and 28 days after PPVE. Results: NEL-volume and NEL-ratio increases were significantly higher in group A at 14 and 28 days after PPVE (78 and 52% and 91 and 66%, respectively) than in group B (32 and 12% and 28 and 10%, respectively) (p < 0.05). Percent change of the EL-volume was significantly higher for group A at 28 days after PPVE. No statistically significant difference was found between the groups regarding hepatocyte proliferation on the NEL and apoptosis on the EL at both time intervals. Conclusion: PPVE using NBCA is more efficient and causes more NEL hypertrophy than microspheres.« less
Monteiro, Thaíssa S; Correia, Marcelo G; Golebiovski, Wilma F; Barbosa, Giovanna Ianini F; Weksler, Clara; Lamas, Cristiane C
Embolic complications of infective endocarditis are common. The impact of asymptomatic embolism is uncertain. To determine the frequency of emboli due to IE and to identify events associated with embolism. Retrospective analysis of an endocarditis database, prospectively implemented, with a post hoc study driven by analysis of data on embolic events. Data was obtained from the International Collaboration Endocarditis case report forms and additional information on embolic events and imaging reports were obtained from the medical records. Variables associated with embolism were analyzed by the statistical software R version 3.1.0. In the study period, 2006-2011, 136 episodes of definite infective endocarditis were included. The most common complication was heart failure (55.1%), followed by embolism (50%). Among the 100 medical records analyzed for emboli in left-sided infective endocarditis, 36 (36%) were found to have had asymptomatic events, 11 (11%) to the central nervous system and 28 (28%) to the spleen. Cardiac surgery was performed in 98/136 (72%). In the multivariate analysis, splenomegaly was the only associated factor for embolism to any site (p<0.01, OR 4.7, 95% CI 2.04-11). Factors associated with embolism to the spleen were positive blood cultures (p=0.05, OR 8.9, 95% CI 1.45-177) and splenomegaly (p<0.01, OR 9.28, 95% CI 3.32-29); those associated to the central nervous system were infective endocarditis of the mitral valve (p<0.05, OR 3.5, 95% CI 1.23-10) and male gender (p<0.05, OR 3.2, 95% CI 1.04-10). Splenectomy and cardiac surgery did not impact on in-hospital mortality. Asymptomatic embolism to the central nervous system and to the spleen were frequent. Splenomegaly was consistently associated with embolic events. Copyright © 2017 Sociedade Brasileira de Infectologia. Published by Elsevier Editora Ltda. All rights reserved.
Choi, Byung Gil; Van Pelt, Carolyn S.; Wright, Kenneth C.
2007-01-01
Objective We wanted to determine whether transcatheter Ethiodol-based capillary embolization in combination with carboplatin could improve the efficiency of a 1:1 Ethiodol-ethanol mixture (EEM) to ablate kidneys that been inoculated with VX-2 carcinoma. Materials and Methods The right kidney in 34 New Zealand white rabbits were inoculated with fresh VX-2 tumor fragments. One week later, the kidneys were subjected to transarterial treatment (4-5 rabbits/group): Saline infusion (Group 1); carboplatin infusion (5 or 10 mg, Groups 2A and 2B); carboplatin-Ethiodol (CE) alone (Group 3) and followed by main renal artery occlusion with ethanol (RAO) (Group 4); carboplatin-EEM (C-EEM) followed by RAO (Group 5); carboplatin infusion followed by EEM plus RAO (Group 6); and EEM followed by RAO (Group 7). The animals were followed for up to 3-weeks. The treated kidneys were evaluated angiographically and macroscopically. The kidneys that showed successful embolization macroscopically were entirely cut into serial sections, and these were examined microscopically. Histologically, the kidneys were evaluated on the basis of the residual tumor found in the serial sections. Results The results obtained with carboplatin infusion alone (Groups 2A and 2B) and CE without RAO (Group 3) were similar to those of the control animals (Group 1). Kidneys from Groups 4-7 demonstrated macroscopically successful embolization with histologically proven complete renal parenchyma infarction; however, some residual tumor was evident in all but one animal. Conclusion None of the Ethiodol-based modalities combined with locoregional carboplatin were more efficacious for tumor ablation than EEM alone. PMID:17420631
Leng, Lewis Z; Kimball, David; Marcus, Joshua; Knopman, Jared; Laufer, Ilya; Bilsky, Mark; Gobin, Y Pierre
2016-01-01
Objective The existing literature regarding preoperative cervical spinal tumor embolization is sparse, with few discussions on the indications, risks, and best techniques. We present our experience with the preoperative endovascular management of hypervascular cervical spinal tumors. Methods We performed a retrospective review of all patients who underwent preoperative spinal angiography (regardless of whether tumor embolization was performed) at our institution (from 2002 to 2012) for primary and metastatic cervical spinal tumors. Tumor vascularity was graded from 0 (tumor blush equal to the normal adjacent vertebral body) to 3 (intense tumor blush with arteriovenous shunting). Tumors were considered “hypervascular” if they had a tumor vascular grade from 1 to 3. Embolic materials included particles, liquid embolics, and detachable coils. The main embolization technique was superselective catheterization of an arterial tumor feeder followed by injection of embolic material. This technique could be used alone or supplemented with occlusion of dangerous anastomoses of the vertebral artery as needed to prevent inadvertent embolization of the vertebrobasilar system. In cases when superselective catheterization of the tumoral feeder was not feasible, embolization was performed from a proximal catheter position after occlusion of branches supplying areas other than the tumor (“flow diversion”). Results A total of 47 patients with 49 cervical spinal tumors were included in this study. Of the 49 total tumors, 41 demonstrated increased vascularity (vascularity score > 0). The most common tumor pathology in our series was renal cell carcinoma (RCC) (N = 16; 32.7% of all tumors) followed by thyroid carcinoma (N = 7; 14.3% of all tumors). Tumor embolization was undertaken in 25 hypervascular tumors resulting in complete, near-complete, and partial embolization in 36.0% (N = 9), 44.0% (N = 11), and 20.0% (N = 5) of embolized tumors, respectively. We embolized 42 tumor feeders in 25 tumors. The most commonly embolized tumor feeders were branches of the vertebral artery (19.0%; N = 8), the deep cervical artery (19.0%; N = 8), and the ascending cervical artery (19.0%; N = 8). Sixteen hypervascular tumors were not embolized because of minimal hypervascularity (8/16), unacceptably high risk of spinal cord or vertebrobasilar ischemia (4/16), failed superselective catheterization of tumor feeder (3/16), and cancellation of surgery (1/16). Vertebral artery occlusion was performed in 20% of embolizations. There were no new post-procedure neurological deficits or any serious adverse events. Estimated blood loss data from this cohort show a significant decrease in operative blood loss for embolized tumors of moderate and significant hypervascularity. Conclusions Preoperative embolization of cervical spinal tumors can be performed safely and effectively in centers with significant experience and a standardized approach. PMID:27020696
Looking for the Ideal Particle: An Experimental Embolization Study
DOE Office of Scientific and Technical Information (OSTI.GOV)
Senturk, Cagin, E-mail: caginsenturk@yahoo.co; Cakir, Volkan; Yorukoglu, Kutsal
This study sought to compare the most frequently used embolic particles in an animal model. In 16 New Zealand white rabbits, right renal arteries were embolized using four different embolic particles (polyvinyl alcohol [PVA] particles, 150-250 {mu}m; PVA microspheres [PVAMs], 150-300 {mu}m; Tris-acryl gelatin microspheres [TGMs], 100-300 {mu}m; expanding microspheres [EXMs], 50-100 {mu}m). Quantity of embolic material used, embolization time, and angiographic patterns were documented. Fourteen days later, a control angiography was done to document angiographic recanalization and all animals were sacrificed. Histopathological specimens were analyzed for microscopic appearance and granulometric size of the particles, extravasation of the particles, perivascularmore » inflammation, and neocapillarization. The volume of the infarct area in each kidney was calculated. Results revealed a significantly lesser amount of embolic material used in the EXM group (p = 0.020). The angiographic recanalization rate in the EXM group (100%), compared with the PVA (0%) and TGM (0%) groups, was found to be statistically significant (p = 0.014). Although 75% of the renal arteries embolized with PVAMs were recanalized, this was not found to be statistically significant (p = 0.071). Occlusion levels in the PVA group were more proximal than with any of the microspheres. While there was no extravasation in the TGM group, extravasation rates in the PVA, PVAM, and EXM groups were 50%, 25%, and 75%, respectively. A mild degree of inflammation was noted in the PVA, PVAM, and TGM groups. EXMs caused a moderate degree of inflammation in two kidneys (50%). There was neocapillarization in the vessel lumen in all kidneys in the PVA and PVAM groups. The difference was significant (p = 0.014) compared with the TGM and EXM groups, which did not have any neocapillarization. Regarding infarct area volumes, the difference among the groups was significant (p = 0.022). EXMs caused significantly (p = 0.021) less infarction than the other embolic agents. We conclude that EXMs are less efficient due to a high recanalization rate and lesser volume of infarct compared with the other embolic agents in the rabbit kidney model. The most efficient embolization was seen in kidneys embolized with TGMs.« less
Chi, Cuong Tran; Nguyen, Dang; Duc, Vo Tan; Chau, Huynh Hong; Son, Vo Tan
2014-01-01
We report our experience in treatment of traumatic direct carotid cavernous fistula (CCF) via endovascular intervention. We hereof recommend an additional classification system for type A CCF and suggest respective treatment strategies. Only type A CCF patients (Barrow's classification) would be recruited for the study. Based on the angiographic characteristics of the CCF, we classified type A CCF into three subtypes including small size, medium size and large size fistula depending on whether there was presence of the anterior carotid artery (ACA) and/or middle carotid artery (MCA). Angiograms with opacification of both ACA and MCA were categorized as small size fistula. Angiograms with opacification of either ACA or MCA were categorized as medium size fistula and those without opacification of neither ACA nor MCA were classified as large size fiatula. After the confirm angiogram, endovascular embolization would be performed impromptu using detachable balloon, coils or both. All cases were followed up for complication and effect after the embolization. A total of 172 direct traumatic CCF patients were enrolled. The small size fistula was accountant for 12.8% (22 cases), medium size 35.5% (61 cases) and large size fistula accountant for 51.7% (89 cases). The successful rate of fistula occlusion under endovascular embolization was 94% with preservation of the carotid artery in 70%. For the treatment of each subtype, a total of 21/22 cases of the small size fistulas were successfully treated using coils alone. The other single case of small fistula was defaulted. Most of the medium and large size fistulas were cured using detachable balloons. When the fistula sealing could not be obtained using detachable balloon, coils were added to affirm the embolization of the cavernous sinus via venous access. There were about 2.9% of patient experienced direct carotid artery puncture and 0.6% puncture after carotid artery cut-down exposure. About 30% of cases experienced sacrifice of the parent vessels and it was associated with sizes of the fistula. Total severe complication was about 2.4% which included 1 death (0.6%) due to vagal shock; 1 transient hemiparesis post-sacrifice occlusion of the carotid artery but the patient had recovered after 3 months; 1 acute thrombus embolism and the patient was completely saved with recombinant tissue plaminogen activator (rTPA); 1 balloon dislodgement then got stuck at the anterior communicating artery but the patient was asymptomatic. Endovascular intervention as the treatment of direct traumatic CCF had high cure rate and low complication with its ability to preserve the carotid artery. It also can supply flexible accesses to the fistulous site with various alternative embolic materials. The new classification of type A CCF based on angiographic features was helpful for planning for the embolization. Coil should be considered as the first embolic material for small size fistula meanwhile detachable balloons was suggested as the first-choice embolic agent for the medium and large size fistula.
Spontaneous soft tissue hematomas.
Dohan, A; Darnige, L; Sapoval, M; Pellerin, O
2015-01-01
Spontaneous muscle hematomas are a common and serious complication of anticoagulant treatment. The incidence of this event has increased along with the rise in the number of patients receiving anticoagulants. Radiological management is both diagnostic and interventional. Computed tomography angiography (CTA) is the main tool for the detection of hemorrhage to obtain a positive, topographic diagnosis and determine the severity. Detection of an active leak of contrast material during the arterial or venous phase is an indication for the use of arterial embolization. In addition, the interventional radiological procedure can be planned with CTA. Arterial embolization of the pedicles that are the source of the bleeding is an effective technique. The rate of technical and clinical success is 90% and 86%, respectively. Copyright © 2015 Éditions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.
Onyx embolization of anterior condylar confluence dural arteriovenous fistula
Takemoto, Koichiro; Tateshima, Satoshi; Rastogi, Sachin; Gonzalez, Nestor; Jahan, Reza; Duckwiler, Gary; Vinuela, Fernando
2013-01-01
The anterior condylar confluence (ACC) is a small complex venous structure located medial to the jugular vein and adjacent to the hypoglossal canal. To our knowledge, this is the first report of transvenous Onyx embolization for ACC dural arteriovenous fistula (DAVF). Three patients with ACC DAVF were treated using the Onyx liquid embolic agent with or without detachable coils. Complete angiographic obliteration of the fistulas was achieved in all cases without permanent lower cranial neuropathy. This report suggests that the controlled penetration of Onyx is advantageous in order to obliterate ACC DAVFs with a small amount of embolic material. PMID:23459160
DOE Office of Scientific and Technical Information (OSTI.GOV)
Picel, Andrew C., E-mail: apicel@ucsd.edu; Koo, Sonya J.; Roberts, Anne C.
PurposeThe purpose of the study was to evaluate the technique and outcomes of transcatheter arterial embolization (TAE) with n-butyl cyanoacrylate (NBCA) for the treatment of acquired uterine arteriovenous malformations (AVMs).Materials and methodsA retrospective review identified five women treated for suspected acquired uterine AVMs with TAE at our institution. Four women (80 %) presented with heavy or intermittent vaginal bleeding after obstetric manipulation. One woman (20 %) was treated for an incidental AVM discovered on ultrasound after an uncomplicated cesarean section. Three women underwent one embolization procedure and two women required two procedures. Embolization material included NBCA in six procedures (80 %) and gelatinmore » sponge in one procedure (20 %).ResultsEmbolization resulted in angiographic stasis of flow in all seven procedures. Four women (80 %) presented with vaginal bleeding which was improved after treatment. One woman returned 24 days after unilateral embolization with recurrent bleeding, which resolved after retreatment. One woman underwent two treatments for an asymptomatic lesion identified on ultrasound. There were no major complications. Three women (60 %) experienced mild postembolization pelvic pain that was controlled with non-steroidal anti-inflammatory drugs. Three women (60 %) had pregnancies and deliveries after embolization.ConclusionsTAE is a safe alternative to surgical therapy for acquired uterine AVMs with the potential to maintain fertility. Experience from this case series suggests that NBCA provides predictable and effective occlusion.« less
Transcatheter arterial embolization for upper gastrointestinal tract bleeding
Širvinskas, Audrius; Smolskas, Edgaras; Brimienė, Vilma; Brimas, Gintautas
2017-01-01
Introduction Transcatheter arterial embolization is a possible treatment for patients with recurrent bleeding from the upper gastrointestinal tract after failed endoscopic management and is also an alternative to surgical treatment. Aim To analyze the outcomes of transcatheter arterial embolization and identify the clinical and technical factors that influenced the rates of morbidity and mortality. Material and methods A retrospective analysis was carried out, based on the data of 36 patients who underwent transcatheter arterial embolization for acute nonvariceal upper gastrointestinal bleeding in 2013 to 2015 in our center. An analysis was performed between early rebleeding rates, mortality and the following factors: patient sex, age, number of units of packed red blood cells and packed plasma administered to the patients, length of hospital stay, therapeutic or prophylactic embolization. Results The technical success rate of the embolization procedure was 100%. There were 15 (41.70%) therapeutic embolizations and 21 (58.3%) prophylactic embolizations. There was a 77.8% clinical success rate. Following embolization, 10 (27.80%) patients had repeated bleeding and 9 (25.0%) patients died. Significant associations were found between rebleeding and prophylactic embolization (OR = 10.53; p = 0.04) and between mortality and prophylactic embolization (OR = 10.53; p = 0.04) and units of packed red blood cells (OR = 1.25; p < 0.01). Conclusions In our experience, transcatheter arterial embolization is a safe treatment method for acute nonvariceal upper gastrointestinal bleeding and a possible alternative to surgery for high-risk patients. PMID:29362654
Onyx(®) in endovascular treatment of cerebral arteriovenous malformations - a review.
Szajner, Maciej; Roman, Tomasz; Markowicz, Justyna; Szczerbo-Trojanowska, Małgorzata
2013-07-01
Arteriovenous malformation (AVM) is an abnormal connection between arteries and veins, bypassing the capillary system. In most cases, the disorder may be asymptomatic. The objective of endovascular AVM treatment is set individually for each case upon consultations with a neurosurgeon and a neurologist. The endpoint of the treatment should consist in prevention of AVM bleeding in a management procedure characterized by a significantly lower risk of complications as compared to the natural history of AVM. Endovascular interventions within AVM may include curative exclusion of AVM from circulation, embolization adjuvant to resection or radiation therapy, targeted closure of a previously identified bleeding site as well as palliative embolization. Onyx was first described in the 1990s. It is a non-adhesive and radiolucent compound. Onyx-based closure of the lumen of the targeted vessel is obtained by means of precipitation. The process is enhanced peripherally to the main flux of the injected mixture. This facilitates angiographic monitoring of embolization at any stage. The degree of lumen closure is associated with the location of the vessel. Supratentorial and cortical locations are most advantageous. Dense and plexiform structure of AVM nidus as well as a low number of supplying vessels and a single superficial drainage vein are usually advantageous for Onyx administration. Unfavorable factors include nidus drainage into multiple compartments as well as multiarterial supply of the AVM, particularly from meningeal arteries, en-passant arteries or perforating feeders. Onyx appears to be a safe and efficient material for embolization of cerebral AVMs, also in cases of intracranial bleeding associated with AVM. Curative embolization of small cerebral AVMs is an efficient and safe alternative to neurosurgical and radiosurgical methods. Careful angiographic assessment of individual arteriovenous malformations should be performed before each Onyx administration.
Onyx® in endovascular treatment of cerebral arteriovenous malformations – a review
Szajner, Maciej; Roman, Tomasz; Markowicz, Justyna; Szczerbo-Trojanowska, Małgorzata
2013-01-01
Summary Arteriovenous malformation (AVM) is an abnormal connection between arteries and veins, bypassing the capillary system. In most cases, the disorder may be asymptomatic. The objective of endovascular AVM treatment is set individually for each case upon consultations with a neurosurgeon and a neurologist. The endpoint of the treatment should consist in prevention of AVM bleeding in a management procedure characterized by a significantly lower risk of complications as compared to the natural history of AVM. Endovascular interventions within AVM may include curative exclusion of AVM from circulation, embolization adjuvant to resection or radiation therapy, targeted closure of a previously identified bleeding site as well as palliative embolization. Onyx was first described in the 1990s. It is a non-adhesive and radiolucent compound. Onyx-based closure of the lumen of the targeted vessel is obtained by means of precipitation. The process is enhanced peripherally to the main flux of the injected mixture. This facilitates angiographic monitoring of embolization at any stage. The degree of lumen closure is associated with the location of the vessel. Supratentorial and cortical locations are most advantageous. Dense and plexiform structure of AVM nidus as well as a low number of supplying vessels and a single superficial drainage vein are usually advantageous for Onyx administration. Unfavorable factors include nidus drainage into multiple compartments as well as multiarterial supply of the AVM, particularly from meningeal arteries, en-passant arteries or perforating feeders. Onyx appears to be a safe and efficient material for embolization of cerebral AVMs, also in cases of intracranial bleeding associated with AVM. Curative embolization of small cerebral AVMs is an efficient and safe alternative to neurosurgical and radiosurgical methods. Careful angiographic assessment of individual arteriovenous malformations should be performed before each Onyx administration. PMID:24115958
Kim, Dae Yoon; Park, Jung Cheol; Kim, Jae Kyun; Sung, Yu Sub; Park, Eun Suk; Kwak, Jae Hyuk; Choi, Choong-Gon
2015-01-01
Purpose Diffusion-weighted MR images (DWI) obtained after endovascular treatment of cerebral aneurysms frequently show multiple high-signal intensity (HSI) dots. The purpose of this study was to see whether we could reduce their incidence after embolization of unruptured cerebral aneurysms by modification of our coiling technique, which involves the deliberate aspiration of the microcatheter lumen right after delivery of each detachable coil into the aneurysm sac. Materials and Methods From January 2011 to June 2011, all 71 patients with unruptured cerebral aneurysms were treated using various endovascular methods. During the earlier period, 37 patients were treated using our conventional embolization technique (conventional period). Then 34 patients were treated with a modified coiling technique (modified period). DWI was obtained on the following day. We compared the occurrence of any DWI HSI lesions and the presence of the symptomatic lesions during the two time periods. Results The incidence of the DWI HSI lesions differed significantly at 89.2% (33/37) during the conventional period and 26.5% (9/34) during the modified period (p < 0.0001). The incidence of symptomatic lesions differed between the two periods (29.7% during the conventional period vs. 2.9% during the modified period, p < 0.003). Conclusion Aspiration of the inner content of the microcatheter right after detachable coil delivery was helpful for the reduction of the incidence of microembolisms after endovascular coil embolization for the treatment of unruptured cerebral aneurysms. PMID:26389009
DOE Office of Scientific and Technical Information (OSTI.GOV)
Morishita, Hiroyuki, E-mail: hmorif@koto.kpu-m.ac.jp; Yamagami, Takuji; Takeuchi, Yoshito
2012-08-15
Although n-butyl-2-cyanoacrylate (NBCA) has been used as an effective liquid embolization material, its indication for pseudoaneurysms has seemingly been limited because of the technical difficulties of using NBCA, such as reflux to the parent artery and causing significant infarction. Thus, considerable skill in using NBCA or a device to control blood flow during its polymerization is required to achieve embolization without severe complications. We report our new technique for controlling blood flow using diluted epinephrine in transcatheter arterial NBCA embolization of five pseudoaneurysms in four cases secondary to hemosuccus pancreaticus.
International survey on neuroradiological interventional and therapeutic devices and materials.
van den Berg, René; Mayer, Thomas E
2015-12-01
A web-based survey was performed among the members of the World Federation of Interventional and Therapeutic Neuroradiology to determine the differences in availability, pricing, and performance of endovascular devices with special focus on coils, intra-arterial stroke devices, detachable balloons, and liquid embolic materials. The results of this survey show that the quality of the majority of interventional neuroradiology devices is good and compatibility issues are limited. Individual action towards suppliers is recommended to discuss the availability and pricing of devices and embolization materials. © The Author(s) 2015.
Analysis of the Quality of Information Obtained About Uterine Artery Embolization From the Internet
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tavare, Aniket N.; Alsafi, Ali, E-mail: ali.alsafi03@imperial.ac.uk; Hamady, Mohamad S.
Purpose: The Internet is widely used by patients to source health care-related information. We sought to analyse the quality of information available on the Internet about uterine artery embolization (UAE). Materials and Methods: We searched three major search engines for the phrase 'uterine artery embolization' and compiled the top 50 results from each engine. After excluding repeated sites, scientific articles, and links to documents, the remaining 50 sites were assessed using the LIDA instrument, which scores sites across the domains of accessibility, usability, and reliability. The Fleisch reading ease score (FRES) was calculated for each of the sites. Finally, wemore » checked the country of origin and the presence of certification by the Health On the Net Foundation (HONcode) as well as their effect on LIDA and FRES scores.ResultsThe following mean scores were obtained: accessibility 48/60 (80%), usability 42/54 (77%), reliability 20/51 (39%), total LIDA 110/165 (67%), and FRES 42/100 (42%). Nine sites had HONcode certification, and this was associated with significantly greater (p < 0.05) reliability and total LIDA and FRES scores. When comparing sites between United Kingdom and United States, there was marked variation in the quality of results obtained when searching for information on UAE (p < 0.05). Conclusion: In general, sites were well designed and easy to use. However, many scored poorly on the reliability of their information either because they were produced in a non-evidence-based way or because they lacking currency. It is important that patients are guided to reputable, location-specific sources of information online, especially because prominent search engine rank does not guarantee reliability of information.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Onozawa, Shiro, E-mail: onozawa@nms.ac.jp; Murata, Satoru, E-mail: genji@nms.ac.jp; Mine, Takahiko, E-mail: takahikomine@gmail.com
PurposeTo evaluate the feasibility of a novel embolization technique, the Amplatzer vascular plug (AVP) anchoring technique, to stabilize the delivery system for microcoil embolization.Materials and methodsThree patients were enrolled in this study, including two cases of internal iliac artery aneurysms and one case of internal iliac arterial occlusion prior to endovascular aortic repair. An AVP was used in each case for embolization of one target artery, and the AVP was left in place. The AVP detachment wire was then used as an anchor to stabilize the delivery system for microcoil embolization to embolize the second target artery adjacent to themore » first target artery. The microcatheter for the microcoils was inserted parallel to the AVP detachment wire in the guiding sheath or catheter used for the AVP.ResultsThe AVP anchoring technique was achieved and the microcatheter was easily advanced to the second target artery in all three cases.ConclusionThe AVP anchoring technique was found to be feasible to advance the microcatheter into the neighboring artery of an AVP-embolized artery.« less
Preoperative Embolization of Extra-axial Hypervascular Tumors with Onyx
Fusco, Matthew R.; Salem, Mohamed M.; Reddy, Arra S.; Ogilvy, Christopher S.; Kasper, Ekkehard M.; Thomas, Ajith J.
2016-01-01
Objective Preoperative endovascular embolization of intracranial tumors is performed to mitigate anticipated intraoperative blood loss. Although the usage of a wide array of embolic agents, particularly polyvinyl alcohol (PVA), has been described for a variety of tumors, literature detailing the efficacy, safety and complication rates for the usage of Onyx is relatively sparse. Materials and Methods We reviewed our single institutional experience with pre-surgical Onyx embolization of extra-axial tumors to evaluate its efficacy and safety and highlight nuances of individualized cases. Results Five patients underwent pre-surgical Onyx embolization of large or giant extra-axial tumors within 24 hours of surgical resection. Four patients harbored falcine or convexity meningiomas (grade I in 2 patients, grade II in 1 patient and grade III in one patient), and one patient had a grade II hemangiopericytoma. Embolization proceeded uneventfully in all cases and there were no complications. Conclusion This series augments the expanding literature confirming the safety and efficacy of Onyx in the preoperative embolization of extra-axial tumors, underscoring its advantage of being able to attain extensive devascularization via only one supplying pedicle. PMID:27114961
Arterial embolization with Onyx of head and neck paragangliomas.
Michelozzi, Caterina; Januel, Anne Christine; Cuvinciuc, Victor; Tall, Philippe; Bonneville, Fabrice; Fraysse, Bernard; Deguine, Olivier; Serrano, Elie; Cognard, Christophe
2016-06-01
To report the morbidity and long term results in the treatment of paragangliomas by transarterial embolization with ethylene vinyl alcohol (Onyx), either as preoperative or palliative treatment. Between September 2005 and 2012, 18 jugulotympanic, 7 vagal, and 4 carotid body paragangliomas (CBPs) underwent Onyx embolization, accordingly to our head and neck multidisciplinary team's decision. CBPs were embolized preoperatively. Jugulotympanic and vagal paragangliomas underwent surgery when feasible, otherwise palliative embolization was carried out alone, or in combination with radiotherapy or tympanic surgery in the case of skull base or tympanic extension. Treatment results, and clinical and MRI follow-up data were recorded. In all cases, devascularization of at least 60% of the initial tumor blush was obtained; 6 patients underwent two embolizations. Post-embolization, 8 patients presented with cranial nerve palsy, with partial or complete regression at follow-up (mean 31 months, range 3-86 months), except for 2 vagal and 1 hypoglossal palsy. 10 patients were embolized preoperatively; 70% were cured after surgery and 30% showed residual tumor. 19 patients received palliative embolization, of whom 5 underwent radiotherapy and 3 received tympanic surgery post-embolization. Long term follow-up of palliative embolization resulted in tumor volume stability (75%) or extension in intracranial or tympanic compartments. Onyx embolization of CBPs resulted in more difficult surgical dissection in 2 of 4 cases. Onyx embolization is a valuable alternative to surgery in the treatment of jugulotympanic and vagal paragangliomas; tympanic surgery or radiosurgery of the skull base should be considered in selected cases. Preoperative Onyx embolization of CBPs is not recommended. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stampfl, Sibylle; Stampfl, Ulrike; Bellemann, Nadine
The objective of this study was to evaluate inflammatory response and recanalization after embolization with a new spherical embolic agent based on a core and shell design with a hydrogel core of polymethylmethacrylate (PMMA) and a Polyzene-F nanoscale coating in a porcine kidney model. Thirty-six minipigs were enrolled for superselective renal embolization. Polyzene-F-coated PMMA particles and uncoated PMMA particles with a diameter of 300-600 {mu}m were used. Either 4 or 12 weeks post-embolization, arteriography of the embolized kidneys was performed and then compared with pre- and immediate post-embolization arteriograms using a specific recanalization score to determine the extent of recanalization.more » Using a microscopic inflammation score (Banff classification), the embolized organs were examined for local inflammatory effects which occurred in response to the embolic agent. In Polyzene-F-coated particles, the Banff classification showed an average inflammation score of 0.26 {+-} 0.58 at 4 weeks and of 0.08 {+-} 0.28 at 12 weeks. In uncoated particles, the Banff score measured 0.37 {+-} 0.6 at 4 weeks, which was higher, but without a statistically significant difference. According to the recanalization score used in this study, mild angiographic recanalization was evident in all groups, without statistically significant differences (3.0 {+-} 0.71 in coated particles, 3.09 {+-} 0.81 in uncoated particles; p = 0.74). We conclude that both uncoated hydrogel particles and Polyzene-F-coated embolic agents triggered virtually no inflammatory response and effectively occluded target arteries. This study demonstrates good biocompatibility of the new embolic material. As in other spherical embolic agents, recanalization can occur to some degree.« less
Transcatheter Coil Embolization of Splenic Artery Aneurysm
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yamamoto, Satoshi, E-mail: s-yama@hyo-med.ac.jp; Hirota, Shozo; Maeda, Hiroaki
2008-05-15
The purpose of this study was to evaluate clinical results and technical problems of transcatheter coil embolization for splenic artery aneurysm. Subjects were 16 patients (8 men, 8 women; age range, 40-80 years) who underwent transcatheter embolization for splenic artery aneurysm (14 true aneurysms, 2 false aneurysms) at one of our hospitals during the period January 1997 through July 2005. Two aneurysms (12.5%) were diagnosed at the time of rupture. Multiple splenic aneurysms were found in seven patients. Aneurysms were classified by site as proximal (or strictly ostial) (n = 3), middle (n = 3), or hilar (n = 10).more » The indication for transcatheter arterial embolization was a false or true aneurysm 20 mm in diameter. Embolic materials were fibered coils and interlocking detachable coils. Embolization was performed by the isolation technique, the packing technique, or both. Technically, all aneurysms were devascularized without severe complications. Embolized aneurysms were 6-40 mm in diameter (mean, 25 mm). Overall, the primary technical success rate was 88% (14 of 16 patients). In the remaining 2 patients (12.5%), partial recanalization occurred, and re-embolization was performed. The secondary technical success rate was 100%. Seven (44%) of the 16 study patients suffered partial splenic infarction. Intrasplenic branching originating from the aneurysm was observed in five patients. We conclude that transcatheter coil embolization should be the initial treatment of choice for splenic artery aneurysm.« less
de Castro-Afonso, L H; Nakiri, G S; Oliveira, R S; Santos, M V; Santos, A C Dos; Machado, H R; Abud, D G
2016-06-01
Intracranial arteriovenous malformations (AVMs) are the most frequent cause of hemorrhagic strokes in the pediatric population. The study aim was to retrospectively assess the safety and efficacy of Onyx embolization with the intention to cure AVMs in a pediatric population. A retrospective analysis of all patients (<18 years) who underwent endovascular embolization using Onyx at our institution was conducted. The primary endpoint was the composite complete angiographic occlusion of AVM immediately after the last embolization session that had no procedure-related complication requiring emergency surgery. Secondary endpoints were angiographic occlusion rates, procedure-related complications, and clinical outcomes after treatment and at the 6-month follow-up Twenty-three patients (mean age, 11.7 years) underwent a total of 45 embolization sessions. The median Spetzler-Martin grade was 3 (range 1 to 4). The primary endpoint was achieved in 19 patients (82.6 %). Complete angiographic occlusion of the AVM was obtained in 21 patients (91.3 %) immediately after embolization and at the 6-month follow-up. Embolization-related complications were observed in three patients (13 %). None of the complications resulted in permanent functional disability or death. In two patients (8.7 %), the AVM could not be completely occluded by embolization alone and the patients were referred to radiosurgery and microsurgery, respectively. Onyx embolization of AVM in pediatric patients with the intention to cure resulted in high occlusion rates without increasing neurological disability or death. The development of new embolization techniques and devices seems to improve the safety of Onyx embolization.
Lee, Cheng-Chia; Chen, Ching-Jen; Ball, Benjamin; Schlesinger, David; Xu, Zhiyuan; Yen, Chun-Po; Sheehan, Jason
2015-07-01
Onyx, an ethylene-vinyl alcohol copolymer mixed in a dimethyl sulfoxide solvent, is currently one of the most widely used liquid materials for embolization of intracranial arteriovenous malformations (AVMs). The goal of this study was to define the risks and benefits of stereotactic radiosurgery (SRS) for patients who have previously undergone partial AVM embolization with Onyx. Among a consecutive series of 199 patients who underwent SRS between January 2007 and December 2012 at the University of Virginia, 25 patients had Onyx embolization prior to SRS (the embolization group). To analyze the obliteration rates and complications, 50 patients who underwent SRS without prior embolization (the no-embolization group) were matched by propensity score method. The matched variables included age, sex, nidus volume before SRS, margin dose, Spetzler-Martin grade, Virginia Radiosurgery AVM Scale score, and median imaging follow-up period. After Onyx embolization, 18 AVMs were reduced in size. Total obliteration was achieved in 6 cases (24%) at a median of 27.5 months after SRS. In the no-embolization group, total obliteration was achieved in 20 patients (40%) at a median of 22.4 months after SRS. Kaplan-Meier analysis demonstrated obliteration rates of 17.7% and 34.1% in the embolization group at 2 and 4 years, respectively. In the no-embolization group, the corresponding obliteration rates were 27.0% and 55.9%. The between-groups difference in obliteration rates after SRS did not achieve statistical significance. The difference in complications, including adverse radiation effects, hemorrhage episodes, seizure control, and patient mortality also did not reach statistical significance. Onyx embolization can effectively reduce the size of many AVMs. This case-control study did not show any statistically significant difference in the rates of embolization or complications after SRS in patients who had previously undergone Onyx embolization and those who had not.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Labby, Zacariah E., E-mail: zelabby@humonc.wisc.edu; Chaudhary, Neeraj; Gemmete, Joseph J.
2015-04-15
Purpose: The therapeutic regimen for cranial arteriovenous malformations often involves both stereotactic radiosurgery and endovascular embolization. Embolization agents may contain tantalum or other contrast agents to assist the neurointerventionalists, leading to concerns regarding the dosimetric effects of these agents. This study investigated dosimetric properties of n-butyl cyanoacrylate (n-BCA) plus lipiodol with and without tantalum powder. Methods: The embolization agents were provided cured from the manufacturer with and without added tantalum. Attenuation measurements were made for the samples and compared to the attenuation of a solid water substitute using a 6 MV photon beam. Effective linear attenuation coefficients (ELAC) were derivedmore » from attenuation measurements made using a portal imager and derived sample thickness maps projected in an identical geometry. Probable dosimetric errors for calculations in which the embolized regions are overridden with the properties of water were calculated using the ELAC values. Interface effects were investigated using a parallel plate ion chamber placed at set distances below fixed samples. Finally, Hounsfield units (HU) were measured using a stereotactic radiosurgery CT protocol, and more appropriate HU values were derived from the ELAC results and the CT scanner’s HU calibration curve. Results: The ELAC was 0.0516 ± 0.0063 cm{sup −1} and 0.0580 ± 0.0091 cm{sup −1} for n-BCA without and with tantalum, respectively, compared to 0.0487 ± 0.0009 cm{sup −1} for the water substitute. Dose calculations with the embolized region set to be water equivalent in the treatment planning system would result in errors of −0.29% and −0.93% per cm thickness of n-BCA without and with tantalum, respectively. Interface effects compared to water were small in magnitude and limited in distance for both embolization materials. CT values at 120 kVp were 2082 and 2358 HU for n-BCA without and with tantalum, respectively; dosimetrically appropriate HU values were estimated to be 79 and 199 HU, respectively. Conclusions: The dosimetric properties of the embolization agents are very close to those of water for a 6 MV beam. Therefore, treating the entire intracranial space as uniform in composition will result in less than 1% dosimetric error for n-BCA emboli smaller than 3.4 cm without added tantalum and n-BCA emboli smaller than 1.1 cm with added tantalum. Furthermore, when effective embolization can be achieved by the neurointerventionalist using n-BCA without tantalum, the dosimetric impact of overriding material properties will be lessened. However, due to the high attenuation of embolization agents with and without added tantalum for diagnostic energies, artifacts may occur that necessitate additional imaging to accurately identify the spatial extent of the region to be treated.« less
Sagara, Yoshiko; Kiyosue, Hiro; Tanoue, Shuichi; Shimada, Ryuichi; Hongo, Norio; Kohno, Tatsuyuki; Kawano, Kenji; Mori, Hiromu
2013-06-01
Comprehensive reports concerning selective embolization for arterial bleeding from third molar removal have not been published. We analyzed cases of arterial bleeding from third molar extraction that required transarterial embolization, and we demonstrate representative cases. Five consecutive patients (three men and two women, aged 24 to 37 years) who underwent transarterial embolization at our institution were included in this study. Four of them showed postoperative bleeding after lower third molar removal, and one suffered bleeding after upper third molar extraction. The period of time from extraction to embolization varied from 5 h to 5 weeks. Angiography revealed pseudoaneurysms at the inferior alveolar artery in four cases and at the superior alveolar artery in one case. The pseudoaneurysms were selectively embolized using 25-33 % n-butyl-2-cyanoacrylate (NBCA)-lipiodol. All of the cases showed good results angiographically and clinically. Transit hypoesthesia at the region of the mental nerve was observed in one patient. Selective transarterial embolization is an effective technique for arterial bleeding from third molar removal when it is difficult to obtain hemostasis by dental procedures. Injection of NBCA can be useful when the alveolar artery is too small to embolize with coils.
Jiang, Wenxiao; Shen, Zhaojun; Luo, Hui; Hu, Xiaoli; Zhu, Xueqiong
2016-12-01
Use systematic reviews and meta-analyses to assess the effect of polyvinyl alcohol and tris-acryl gelatin microsphere materials in leiomyoma embolization for symptomatic leiomyomas. We included randomised controlled studies published before January 2015 comparing polyvinyl alcohol and tris-acryl gelatin microsphere materials in uterine leiomyoma embolization for women with symptomatic leiomyomas. The main outcome measures included change of overall quality of life, change of overall symptom severity, changes of uterine and leiomyoma volumes, leiomyoma infarction rate, treatment failure and complications. A total of six randomized controlled studies from 335 studies accounting for 351 women with leiomyomas were identified in this meta-analysis. Compared to polyvinyl alcohol, tris-acryl gelatin microsphere showed a significant benefit in improving the overall quality of life and in reducing uterine volume at three and six months, in reducing overall symptom severity at 6 and 12 months, and furthermore in reducing treatment failure. In addition, tris-acryl gelatin microsphere could significantly reduce leiomyoma volume and decrease <90% complete leiomyoma infarction rate at three months. There were no differences in pain severity, other post-procedural symptoms or medication use in the two groups. A better effect of tris-acryl gelatin microsphere in leiomyoma embolization for patients with symptomatic leiomyoma.
Horák, D; Svec, F; Kálal, J; Adamyan, A; Skuba, N; Titova, M; Dan, V; Varava, B; Trostenyuk, N; Voronkova, O
1988-07-01
In this study we report the results of toxicological, histological and haematological experiments on radiopaque spherical particles based on poly(2-hydroxyethyl methacrylate). These particles have been developed for endovascular occlusion of various organs. Radiopacity was attained by two independent methods: the chemical attachment of radiopaque substances to the hydrogel or the precipitation of radiopaque substances in the hydrogel network. The first method yields particles that appear to have uniformly-distributed contrast material, but in the particles prepared by the second procedure the contrast material is predominantly located on the surface. The visibility of such particles by X-rays makes possible controlled embolus introduction and inspection of the polymer for long periods after embolization. Radiopaque contrasting changes the morphology and reduces the porosity of the material but supports quick thrombus formation. Embolic material implanted in rabbits becomes surrounded by a thin fibrous capsule and undergoes partial organization. This and other results of medico-biological investigations have fully demonstrated the biocompatibility of radiopaque spherical emboli, which can now be used clinically.
Loy, David N; Rich, Keith M; Simpson, Joseph; Dorward, Ian; Santanam, Lakshmi; Derdeyn, Colin P
2009-05-01
This report demonstrates that time-of-flight (TOF) MR angiography is a useful adjunct for planning stereotactic radiosurgery (SRS) of large arteriovenous malformations (AVMs) after staged embolization with Onyx. Onyx (ethylene vinyl copolymer), a recently approved liquid embolic agent, has been increasingly used to exclude portions of large AVMs from the parent circulation prior to SRS. Limiting SRS to regions of persistent arteriovenous shunting and excluding regions eliminated by embolization may reduce unnecessary radiation doses to eloquent brain structures. However, SRS dosimetry planning presents unique challenges after Onyx embolization because it creates extensive artifacts on CT scans, and it cannot be delineated from untreated nidus on standard MR sequences. During the radiosurgery procedure, MR images were obtained using a GE Signa 1.5-T unit. Standard axial T2 fast spin echo high-resolution images (TR 3000 msec, TE 108 msec, slice thickness 2.5 mm) were generated for optimal visualization of brain tissue and AVM flow voids. The 3D TOF MR angiography images of the circle of Willis and vertebral arteries were subsequently obtained to visualize AVM regions embolized with Onyx (TR 37 msec, TE 6.9 msec, flip angle 20 degrees). Adjunct TOF MR angiography images demonstrated excellent contrast between nidus embolized with Onyx and regions of persistent arteriovenous shunting within a large AVM prior to SRS. Additional information derived from these sequences resulted in substantial adjustments to the treatment plan and an overall reduction in the treated tissue volume.
Advances in Degradable Embolic Microspheres: A State of the Art Review
Doucet, Jensen; Kiri, Lauren; O’Connell, Kathleen; Kehoe, Sharon; Lewandowski, Robert J.; Liu, David M.; Abraham, Robert J.; Boyd, Daniel
2018-01-01
Considerable efforts have been placed on the development of degradable microspheres for use in transarterial embolization indications. Using the guidance of the U.S. Food and Drug Administration (FDA) special controls document for the preclinical evaluation of vascular embolization devices, this review consolidates all relevant data pertaining to novel degradable microsphere technologies for bland embolization into a single reference. This review emphasizes intended use, chemical composition, degradative mechanisms, and pre-clinical safety, efficacy, and performance, while summarizing the key advantages and disadvantages for each degradable technology that is currently under development for transarterial embolization. This review is intended to provide an inclusive reference for clinicians that may facilitate an understanding of clinical and technical concepts related to this field of interventional radiology. For materials scientists, this review highlights innovative devices and current evaluation methodologies (i.e., preclinical models), and is designed to be instructive in the development of innovative/new technologies and evaluation methodologies. PMID:29373510
Renal Angiomyolipoma: Mid- to Long-Term Results Following Embolization with Onyx.
Thulasidasan, Narayanan; Sriskandakumar, Srividhiya; Ilyas, Shahzad; Sabharwal, Tarun
2016-12-01
Percutaneous transcatheter embolization is currently the preferred treatment for ruptured or enlarging renal angiomyolipoma (AML), although the optimum choice of embolic material has not yet been established. We present mid- to long-term outcomes following embolization of AMLs with Onyx. Ten AMLs in seven patients (including two with tuberous sclerosis) were embolized with Onyx. Patients were followed-up clinically, with tumour size and renal function measured pre- and post-procedure. Mean pre-treatment AML size was 63.4 mm (range 42-100). Mean clinical follow-up was 431.4 days (range 153-986) and imaging follow-up 284.2 days (range 30-741). There was no haemorrhage from treated lesions within the follow-up period. Of patients who had cross-sectional imaging pre- and post-procedure, mean decrease in AML size of 22 mm was seen after Onyx embolization (p = 0.0058, 95 % CI 9.13-34.87). No significant difference between serum creatinine was seen pre- and post-procedure (p = 0.54, 95 % CI 8.63-4.85). Onyx embolization of renal AMLs is effective in the medium to long term, with theoretical benefits in safety and durability of result.
Sadeh-Gonike, Udi; Magand, Nicolas; Armoiry, Xavier; Riva, Roberto; Labeyrie, Paul Emile; Lamy, Bernadette; Lukaszewicz, Anne-Claire; Lehot, Jean-Jacques; Turjman, Francis; Gory, Benjamin
2018-06-01
Onyx is important embolic material in the endovascular treatment of intracranial dural arteriovenous fistula (DAVF). However, its impact on DAVF occlusion rates, morbidity, mortality, and complication rates is not fully examined. To improve understanding of safety and effectiveness profiles associated with transarterial endovascular treatment using Onyx for intracranial DAVF. We analyzed data from our prospective clinical registry and conducted a systematic review of all previous transarterial embolization studies using Onyx published between January 2005 and December 2015 in MEDLINE and EMBASE. In the prospective study, 41 transarterial procedures were performed in 33 consecutive patients harboring 36 DAVFs. Complete initial exclusion was obtained in 32 of 36 (88.9%) fistulas; 31 fistulas were followed up showing 4 (12.9%) recurrences. Procedure-related morbidity and mortality were 3% and 0%, respectively. The literature review identified 19 studies involving a total of 425 patients with 463 DAVFs. Meta-analysis, including our registry data, showed an initial complete occlusion rate of 82% (95% confidence interval [CI]: 74%, 88%; I2, 70.6%), and recurrence rate at midterm of 2% (95% CI: 0%, 5%; I2, 21.5%). Pooled postoperative neurological deficit, procedure-related morbidity, and mortality rates were 4% (95% CI: 2%, 6%; I2, 0%), 3% (95% CI: 1%, 5%; I2, 0%), and 0%, respectively. This meta-analysis suggests that transarterial embolization with Onyx is a safe treatment modality for DAVFs. Although Onyx showed a low recurrence rate at midterm, the long-term risk is poorly addressed in our study and should warrant a longer follow-up.
Onyx versus nBCA and coils in the treatment of intracranial dural arteriovenous fistulas
Choo, Douglas M
2016-01-01
Background and purpose Intracranial dural arteriovenous fistulas (DAVFs) with cortical venous drainage have significant morbidity and mortality. Complete closure of these lesions is necessary to reduce these risks. The purpose of our study was to compare the outcome of DAVFs treated with Onyx versus those treated with n-Butyl Cyanoacrylate (nBCA) and coil embolization in a case-control study. Compared with nBCA and coil embolization, we hypothesized that Onyx embolization for DAVF is safer and has a higher chance of complete obliteration, with no need for post-embolization surgery for the DAVF. Materials and methods From 1998 to 2015, 29 patients who had DAVFs were treated with endovascular embolization. Of these, 24 patients had imaging available for analysis. Successful closure rates, complications, and procedure time were compared between the embolization techniques. Results The chance of not requiring post-embolization surgery with Onyx (81.8%) was significantly higher (p = 0.005) than with nBCA (22.22%). The complication rate with Onyx (9.1%) tended to be lower compared with that of nBCA (22.22%; p = 0.37). Procedural time was not significantly different between Onyx (mean 267 minutes) and nBCA (mean 288 minutes) (p = 0.59). The odds ratio of a DAVF being treated with Onyx and then requiring no follow-up surgery was 17.5 (95% CI 1.97–155.4). Conclusion Our case-control study suggests that Onyx embolization is superior to nBCA and coil embolization in completely obliterating DAVFs, with higher odds of no post-embolization surgery. We also found that Onyx is safe for embolization of DAVFs, with no associated neurological mortality and morbidity. PMID:26748082
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gupta, Nakul; Patel, Anish; Ensor, Joe
PurposeTo describe the incidence of multiple renal artery pseudoaneurysms (PSA) in patients referred for renal artery embolization following partial nephrectomy and to study its relationship to RENAL nephrometry scores.Materials and MethodsThe medical records of 25 patients referred for renal artery embolization after partial nephrectomy were retrospectively reviewed for the following parameters: size and number of tumors, RENAL nephrometry scores, angiographic abnormalities, technical and clinical outcomes, and estimated glomerular filtration rates (eGFRs) after embolization.ResultsTwenty-four patients had primary renal tumors, while 1 patient had a pancreatic tumor invading the kidney. Multiple tumors were resected in 4 patients. Most patients (92 %) were symptomatic,more » presenting with gross hematuria, flank pain, or both. Angiography revealed PSA with (n = 5) or without (n = 20) AV fistulae. Sixteen patients (64 %) had multiple PSA involving multiple renal vessels. Higher RENAL nephrometry scores were associated with an increasing likelihood of multiple PSA. Multiple vessels were embolized in 14 patients (56 %). Clinical success was achieved after one (n = 22) or two (n = 3) embolization sessions in all patients. Post-embolization eGFR values at different time points after embolization were not significantly different from the post-operative eGFR.ConclusionA majority of patients requiring renal artery embolization following partial nephrectomy have multiple pseudoaneurysms, often requiring selective embolization of multiple vessels. Higher RENAL nephrometry score is associated with an increasing likelihood of multiple pseudoaneurysms. We found transarterial embolization to be a safe and effective treatment option with no long-term adverse effect on renal function in all but one patient with a solitary kidney.« less
Mordasini, Pasquale; Szucs-Farkas, Zsolt; Do, Do-Dai; Gralla, Jan; Kettenbach, Joachim; Hoppe, Hanno
2010-08-01
The latest-generation Amplatzer vascular plug (AVP), the AVP 4, is designed for embolization of smaller vessels without a sheath or guiding catheter. This study evaluated the AVP 4 in peripheral vascular embolization. Embolization with the AVP 4 was attempted in 13 patients (11 men) for trauma (n = 7) and other indications (n = 6). Technical success rate, vascular bed, size of catheter, and number and size of AVP 4 devices were recorded. Embolization with the AVP 4 was successful in 10 of 13 patients (77%). In trauma patients (n = 7), embolization of the splenic artery (n = 4), lumbar artery (n = 2), and superior gluteal artery (n = 1) was performed. In other patients, preoperative embolization of the right portal vein (n = 1), a gastric varix after transjugular intrahepatic portosystemic shunt creation (n = 1), an aneurysm of the internal iliac artery (n = 1), and inferior mesenteric artery (IMA) embolization before aneurysm repair (n = 2) was performed. Sizes of the AVP 4 were 4 mm (n = 6), 6 mm (n = 5), and 8 mm (n = 1). In all patients, 4- and 5-F catheters with a 0.038-inch minimum inner lumen were used. In one patient, IMA embolization was attempted via a femoral approach but was unsuccessful as a result of repeated catheter tip dislocation because of acute angle; coils were used instead. Peripheral embolization with the AVP 4 was successful in the majority of patients. Future comparative study is necessary to evaluate this device's benefits over other embolization materials such as earlier-generation AVPs or microcoils. Copyright (c) 2010 SIR. Published by Elsevier Inc. All rights reserved.
Embolization of traumatic and non-traumatic peripheral vascular lesions with Onyx.
Regine, Renato; Palmieri, Francesco; De Siero, Michele; Rescigno, Antonio; Sica, Vincenzo; Cantarela, Raffaele; Villari, Vincenzo
2015-03-01
The aim of our study is to verify the feasibility and the efficacy of Onyx as embolization agent in the treatment of traumatic and non-traumatic peripheral vascular lesions. In the period between September 2006 and March 2012, we treated with Onyx 26 patients (14 males/12 females; age range, 18-85 years old; mean age, 65 years old), 11 of which with traumatic peripheral vascular lesions and 15 with non-traumatic vascular lesions (9 neoplastic hemorrhagic lesions, 3 arteriovenous malformations (AVMs) and 3 aneurysms). Follow-up controls were performed with clinical examination and by multidetector computed tomography (MDCT) imaging 1, 6, and 12 months after the procedure. All peripheral vascular lesions were embolized with Onyx; 3 patients with aneurysms were treated with Onyx associated with endovascular coils. Four elective and 22 emergency embolization procedures were performed. In all patients, we obtained cessation of bleeding and the complete and permanent embolization of all vascular lesions. Onyx is an effective and safe embolization agent for peripheral vascular lesions.
Microvascular Perfusion Changes following Transarterial Hepatic Tumor Embolization
Johnson, Carmen Gacchina; Sharma, Karun V.; Levy, Elliot B.; Woods, David L.; Morris, Aaron H.; Bacher, John D.; Lewis, Andrew L.; Wood, Bradford J.; Dreher, Matthew R.
2015-01-01
Purpose To quantify changes in tumor microvascular (< 1 mm) perfusion relative to commonly used angiographic endpoints. Materials and Methods Rabbit Vx2 liver tumors were embolized with 100–300-µm LC Bead particles to endpoints of substasis or complete stasis (controls were not embolized). Microvascular perfusion was evaluated by delivering two different fluorophore-conjugated perfusion markers (ie, lectins) through the catheter before embolization and 5 min after reaching the desired angiographic endpoint. Tumor microvasculature was labeled with an anti-CD31 antibody and analyzed with fluorescence microscopy for perfusion marker overlap/mismatch. Data were analyzed by analysis of variance and post hoc test (n = 3–5 per group; 18 total). Results Mean microvascular density was 70 vessels/mm2 ± 17 (standard error of the mean), and 81% ± 1 of microvasculature (ie, CD31+ structures) was functionally perfused within viable Vx2 tumor regions. Embolization to the extent of substasis eliminated perfusion in 37% ± 9 of perfused microvessels (P > .05 vs baseline), whereas embolization to the extent of angiographic stasis eliminated perfusion in 56% ± 8 of perfused microvessels. Persistent microvascular perfusion following embolization was predominantly found in the tumor periphery, adjacent to normal tissue. Newly perfused microvasculature was evident following embolization to substasis but not when embolization was performed to complete angiographic stasis. Conclusions Nearly half of tumor microvasculature remained patent despite embolization to complete angiographic stasis. The observed preservation of tumor microvasculature perfusion with angiographic endpoints of substasis and stasis may have implications for tumor response to embolotherapy. PMID:26321051
In vivo dynamic analysis of water refilling in embolized xylem vessels of intact Zea mays leaves
Ryu, Jeongeun; Hwang, Bae Geun; Lee, Sang Joon
2016-01-01
Background and Aims The refilling of embolized xylem vessels under tension is a major issue in water transport among vascular plants. However, xylem embolism and refilling remain poorly understood because of technical limitations. Direct observation of embolism repair in intact plants is essential to understand the biophysical aspects of water refilling in embolized xylem vessels. This paper reports on details of the water refilling process in leaves of the intact herbaceous monocot plant Zea mays and its refilling kinetics obtained by a direct visualization technique. Methods A synchrotron X-ray micro-imaging technique was used to monitor water refilling in embolized xylem vessels of intact maize leaves. Xylem embolism was artificially induced by using a glass capillary; real-time images of water refilling dynamics were consecutively captured at a frame rate of 50 f.p.s. Key Results Water supply in the radial direction initiates droplet formation on the wall of embolized xylem vessels. Each droplet grows into a water column; this phenomenon shows translation motion or continuous increase in water column volume. In some instances, water columns merge and form one large water column. Water refilling in the radial direction causes rapid recovery from embolism in several minutes. The average water refilling velocity is approx. 1 μm s−1. Conclusions Non-destructive visualization of embolized xylem vessels demonstrates rapid water refilling and gas bubble removal as key elements of embolism repair in a herbaceous monocot species. The refilling kinetics provides new insights into the dynamic mechanism of water refilling phenomena. PMID:27539601
Spiotta, Alejandro M; James, Robert F; Lowe, Stephen R; Vargas, Jan; Turk, Aquilla S; Chaudry, M Imran; Bhalla, Tarun; Janjua, Rashid M; Delaney, John J; Quintero-Wolfe, Stacey; Turner, Raymond D
2015-10-01
Conventional Onyx embolization of cerebral arteriovenous malformations (AVMs) requires lengthy procedure and fluoroscopy times to form an adequate 'proximal plug' which allows forward nidal penetration while preventing reflux and non-targeted embolization. We review our experience with balloon-augmented Onyx embolization of cerebral AVMs using a dual-lumen balloon catheter technique designed to minimize these challenges. Retrospectively acquired data for all balloon-augmented cerebral AVM embolizations performed between 2011 and 2014 were obtained from four tertiary care centers. For each procedure, at least one Scepter C balloon catheter was advanced into the AVM arterial pedicle of interest and Onyx embolization was performed through the inner lumen after balloon inflation via the outer lumen. Twenty patients underwent embolization with the balloon-augmented technique over 24 discreet treatment episodes. There were 37 total arterial pedicles embolized with the balloon-augmented technique, a mean of 1.9 per patient (range 1-5). The treated AVMs were heterogeneous in their location and size (mean 3.3±1.6 cm). Mean fluoroscopy time for each procedure was 48±26 min (28 min per embolized pedicle). Two Scepter C balloon catheter-related complications (8.3% of embolization sessions, 5.4% of pedicles embolized) were observed: an intraprocedural rupture of a feeding pedicle and fracture and retention of a catheter fragment. This multicenter experience represents the largest reported series of balloon-augmented Onyx embolization of cerebral AVMs. The technique appears safe and effective in the treatment of AVMs, allowing more efficient and controlled injection of Onyx with a decreased risk of reflux and decreased fluoroscopy times. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Toguchi, Masafumi, E-mail: e024163@yahoo.co.jp; Tsurusaki, Masakatsu; Numoto, Isao
PurposeTo evaluate the feasibility and safety of the Amplatzer vascular plug (AVP) for preoperative common hepatic embolization (CHA) before distal pancreatectomy with en bloc celiac axis resection (DP-CAR) to redistribute blood flow to the stomach and liver via the superior mesenteric artery (SMA).Materials and MethodsFour patients (3 males, 1 female; median age 69 years) with locally advanced pancreatic body cancer underwent preoperative CHA embolization with AVP. After embolization, SMA arteriography was performed to confirm the alteration of blood flow from the SMA to the proper hepatic artery.ResultsIn three of four patients, technical successes were achieved with sufficient margin from the originmore » of gastroduodenal artery. In one patient, the margin was less than 5 mm, although surgery was successfully performed without any problem. Eventually, all patients underwent the DP-CAR without arterial reconstruction or liver ischemia.ConclusionsAVP application is feasible and safe as an embolic procedure for preoperative CHA embolization of DP-CAR.« less
Park, Jin-Sung; Kim, Jaedong; Lee, Yonggu; Gwon, Jun-Gyo; Park, Ye-Soo
2018-05-07
Percutaneous vertebroplasty (PVP) is a minimally invasive surgical treatment for patients with osteoporotic vertebral compression fracture (OVCF) and can rapidly alleviate pain, improve mobility, and stabilize the vertebrae. However, it has the potential to cause complications such as cement embolism. A 55-year-old female presented with pain in the lumbar region as a chief complaint. PVP was performed after diagnosis of acute OVCFs at L4 and L5. No abnormal symptoms were reported after surgery, but a large cement embolism was observed in her right atrium and ventricle. After discussion in a multi-disciplinary team, the large cement embolism was successfully removed by a combination of endovascular procedure and an inferior vena cava exploration. Surgeons must consider the possibility of intra-cardiac cement embolism after PVP. A hybrid approach of an endovascular procedure and a vascular surgery may be a reasonable treatment option to minimize the surgical procedure in cases of a large intra-cardiac cement embolism.
Complete filter-based cerebral embolic protection with transcatheter aortic valve replacement.
Van Gils, Lennart; Kroon, Herbert; Daemen, Joost; Ren, Claire; Maugenest, Anne-Marie; Schipper, Marguerite; De Jaegere, Peter P; Van Mieghem, Nicolas M
2018-03-01
To evaluate the value of left vertebral artery filter protection in addition to the current filter-based embolic protection technology to achieve complete cerebral protection during TAVR. The occurrence of cerebrovascular events after transcatheter aortic valve replacement (TAVR) has fueled concern for its potential application in younger patients with longer life expectancy. Transcatheter cerebral embolic protection (TCEP) devices may limit periprocedural cerebrovascular events by preventing macro and micro-embolization to the brain. Conventional filter-based TCEP devices cover three extracranial contributories to the brain, yet leave the left vertebral artery unprotected. Patients underwent TAVR with complete TCEP. A dual-filter system was deployed in the brachiocephalic trunk and left common carotid artery with an additional single filter in the left vertebral artery. After TAVR all filters were retrieved and sent for histopathological evaluation by an experienced pathologist. Eleven patients received a dual-filter system and nine of them received an additional left vertebral filter. In the remaining two patients, the left vertebral filter could not be deployed. No periprocedural strokes occurred. We found debris in all filters, consisting of thrombus, tissue derived debris, and foreign body material. The left vertebral filter contained debris in an equal amount of patients as the Sentinel filters. The size of the captured particles was similar between all filters. The left vertebral artery is an important entry route for embolic material to the brain during TAVR. Selective filter protection of the left vertebral artery revealed embolic debris in all patients. The clinical value of complete filter-based TCEP during TAVR warrants further research. © 2017 Wiley Periodicals, Inc.
Hospital costs of acute pulmonary embolism.
Fanikos, John; Rao, Amanda; Seger, Andrew C; Carter, Danielle; Piazza, Gregory; Goldhaber, Samuel Z
2013-02-01
Pulmonary embolism places a heavy economic burden on health care systems, but the components of hospital cost have not been elucidated. We evaluated hospitalized patients with the primary diagnosis of pulmonary embolism. Our goal was to determine the total and component costs associated with their hospital care. We included patients hospitalized at Brigham and Women's Hospital from September 2003 to May 2010. Patient demographics, characteristics, comorbidities, interventions, and treatments were obtained from the electronic medical record. Costs were obtained using the hospital's accounting software and categorized into the areas providing direct patient supplies or care. We identified 991 hospitalized patients with acute pulmonary embolism. In-hospital mortality was 4.2%, and 90-day mortality after hospital discharge was 13.8%. The median length of hospital stay was 3 days, and the mean length of hospital stay was 4 days. The mean total hospitalization cost per patient was $8764. Nursing costs, which included room and board, were $5102. Pharmacy ($966) and radiology ($963) costs were similar. Pharmacy costs ($966) were dominated by the use of low-molecular-weight heparin ($232). Radiology costs ($963) were dominated by the use of diagnostic imaging examinations ($672). During the observation period, an average of 160 patients with pulmonary embolism were admitted each year, requiring an annual hospital expense ranging from $884,814 to $1,866,489. Pulmonary embolism has a high case fatality rate and remains an expensive illness to diagnose and treat. Nursing costs comprise the largest component of costs. Copyright © 2013 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Koike, Yuya, E-mail: r06118@hotmail.co.jp; Nishimura, Jun-ichi, E-mail: jun-ichi-n@nifty.com; Hase, Soichiro, E-mail: haseman@hotmail.co.jp
PurposeThe purpose of this study was to demonstrate a sac angiography technique and evaluate the feasibility of N-butyl cyanoacrylate (NBCA) embolization of the ruptured abdominal aortic aneurysm (AAA) sac in emergency endovascular aneurysm repair (EVAR) in hemodynamically unstable patients.MethodsA retrospective case series of three patients in whom sac angiography was performed during emergency EVAR for ruptured AAA was reviewed. After stent graft deployment, angiography within the sac of aneurysm (sac angiography) was performed by manually injecting 10 ml of contrast material through a catheter to identify the presence and site of active bleeding. In two patients, sac angiography revealed active extravasationmore » of the contrast material, and NBCA embolization with a coaxial catheter system was performed to achieve prompt sealing.ResultsSac angiography was successful in all three patients. In the two patients who underwent NBCA embolization for aneurysm sac bleeding, follow-up computed tomography (CT) images demonstrated the accumulation of NBCA consistent with the bleeding site in preprocedural CT images.ConclusionsEVAR is associated with a potential risk of ongoing bleeding from type II or IV endoleaks into the disrupted aneurysm sac in patients with severe coagulopathy. Therefore, sac angiography and NBCA embolization during emergency EVAR may represent a possible technical improvement in the treatment of ruptured AAA in hemodynamically unstable patients.« less
Endovascular management for significant iatrogenic portal vein bleeding.
Kim, Jong Woo; Shin, Ji Hoon; Park, Jonathan K; Yoon, Hyun-Ki; Ko, Gi-Young; Gwon, Dong Il; Kim, Jin Hyoung; Sung, Kyu-Bo
2017-11-01
Background Despite conservative treatment, hemorrhage from an intrahepatic branch of the portal vein can cause hemodynamic instability requiring urgent intervention. Purpose To retrospectively report the outcomes of hemodynamically significant portal vein bleeding after endovascular management. Material and Methods During a period of 15 years, four patients (2 men, 2 women; median age, 70.5 years) underwent angiography and embolization for iatrogenic portal vein bleeding. Causes of hemorrhage, angiographic findings, endovascular treatment, and complications were reported. Results Portal vein bleeding occurred after percutaneous liver biopsy (n = 2), percutaneous radiofrequency ablation (n = 1), and percutaneous cholecystostomy (n = 1). The median time interval between angiography and percutaneous procedure was 5 h (range, 4-240 h). Common hepatic angiograms including indirect mesenteric portograms showed active portal vein bleeding into the peritoneal cavity with (n = 1) or without (n = 2) an arterioportal (AP) fistula, and portal vein pseudoaneurysm alone with an AP fistula (n = 1). Successful transcatheter arterial embolization (n = 2) or percutaneous transhepatic portal vein embolization (n = 2) was performed. Embolic materials were n-butyl cyanoacrylate alone (n = 2) or in combination with gelatin sponge particles and coils (n = 2). There were no major treatment-related complications or patient mortality within 30 days. Conclusion Patients with symptomatic or life-threatening portal vein bleeding following liver-penetrating procedures can successfully be managed with embolization.
Spontaneous delayed migration/shortening of the pipeline embolization device: report of 5 cases.
Chalouhi, N; Tjoumakaris, S I; Gonzalez, L F; Hasan, D; Pema, P J; Gould, G; Rosenwasser, R H; Jabbour, P M
2013-12-01
Five patients were found to have spontaneous delayed migration/shortening of their Pipeline Embolization Devices on follow-up angiography. The device migrated proximally in 4 patients and distally in 1 patient. One patient had a subarachnoid hemorrhage and died as a result of migration of the Pipeline Embolization Device, and another patient presented with complete MCA occlusion and was left severely disabled. Mismatch in arterial diameter between inflow and outflow vessels was a constant finding. Migration of the Pipeline Embolization Device was managed conservatively, with additional placement of the device, or with parent vessel occlusion. Obtaining complete expansion of the embolization device by using a longer device, increasing vessel coverage, using adjunctive aneurysm coiling, and avoiding dragging and stretching of the device are important preventive measures. Neurointerventionalists should be aware of this potentially fatal complication and take all necessary preventive measures.
Permanent Cortical Blindness After Bronchial Artery Embolization
DOE Office of Scientific and Technical Information (OSTI.GOV)
Doorn, Colette S. van, E-mail: cvandoorn@gmail.com; De Boo, Diederick W., E-mail: d.w.deboo@amc.uva.nl; Weersink, Els J. M., E-mail: e.j.m.weersink@amc.uva.nl
2013-12-15
A 35-year-old female with a known medical history of cystic fibrosis was admitted to our institution for massive hemoptysis. CTA depicted a hypertrophied bronchial artery to the right upper lobe and showed signs of recent bleeding at that location. Bronchial artery embolization (BAE) was performed with gelfoam slurry, because pronounced shunting to the pulmonary artery was present. Immediately after BAE, the patient developed bilateral cortical blindness. Control angiography showed an initially not opacified anastomosis between the embolized bronchial artery and the right subclavian artery, near to the origin of the right vertebral artery. Cessation of outflow in the bronchial circulationmore » reversed the flow through the anastomosis and allowed for spill of embolization material into the posterior circulation. Unfortunately the cortical blindness presented was permanent.« less
Izumi, Takashi; Satow, Tetsu; Srivatanakul, Kittipong; Matsumoto, Yasushi; Terada, Tomoaki; Matsumaru, Yuji; Kiyosue, Hiro
2017-01-01
Purpose Recent reports have posed doubts about the effect of preradiosurgical embolization in brain arteriovenous malformation (AVM) because it makes the planning of stereotactic radiosurgery (SRS) difficult and has the risk of recanalization out of the target. We investigated whether the performance and quality of embolization may influence the success of SRS based on a retrospective case cohort study. Materials and Methods Seventy-three patients who underwent embolization followed by SRS between 2003 and 2012 in eight institutes with neurointerventionists were considered. They were divided into the following two groups at 3 years of follow up after the final SRS: “successful occlusion group” (S group), with radiologically complete occlusion of AVM; and “non-successful occlusion group” (N group) with persistent remnant nidus or abnormal vascular networks. Patient background, AVM profile, embolization performance grade and complications were compared in each group. The quality of embolization was evaluated with the new grading system: embolization performance grade (E grade), specializing the achievement of nidus embolization. E grade A was defined as sufficient nidus embolization with more than half of the total number of feeders achieving nidus penetration. E grade B was defined as less than half achievement of nidus embolization, and E grade C was defines as failure to perform nidus embolization. Results Forty-three patients were included in the S group, and 29 patients were included in the N group. The size and Spetzler-Martin grade of AVM and the rate of diffuse type was higher in the N group without statistical significance. The embolization performance level according to E grade indicated a significantly higher rate of successful embolization with more than 50% of nidus penetration in the S group (P<0.001). This difference was also confirmed in the subanalysis for limited cases, excluding smaller AVMs with complete occlusion with SRS alone (P=0.001). Conclusion The cause of the unsuccessful result of post-embolization SRS might be the large, diffuse angioarchitecture, but proper embolization with a high rate of nidus penetration to avoid recanalization is more important. Effective embolization is essential to contribute to and promote the effect of radiosurgery. PMID:28955512
Arteriography after embolization before distal pancreatectomy with en bloc celiac axis resection.
Yamagami, Takuji; Yoshimatsu, Rika; Kajiwara, Kenji; Ishikawa, Masaki; Murakami, Yoshiaki; Uemura, Kenichiro; Awai, Kazuo
2015-01-01
To evaluate hemodynamics by arteriographic examinations with and without CT in the stomach wall and liver after preoperative embolization to redistribute blood flow to the stomach and liver, which is unified to be supplied from the superior mesenteric artery, before distal pancreatectomy with en bloc celiac axis resection (DP-CAR). In six patients with locally advanced cancer of the pancreatic body in whom DP-CAR was planned, the left gastric artery and common hepatic artery were embolized with coils. Celiac arteriography and superior mesenteric arteriography with and without CT were performed after embolization. In all six patients, intrahepatic arteries and the left gastric artery were not visualized on celiac arteriography. On both superior mesenteric arteriography and CT obtained while contrast medium was infused via the superior mesenteric artery and which was performed immediately after embolization procedures, the right gastric artery, gastroepiploic artery, gastroduodenal artery, and all hepatic arterial branches were clearly detected. Also the distal part of the left gastric artery close to the embolized point was detected with at least one of the imaging modalities. It was clarified radiologically that preoperative embolization results in increased blood supply to the stomach wall and liver through the pancreatic arcade.
Reconfigurable Polymer Networks for Improved Treatment of Intracranial Aneurysms
NASA Astrophysics Data System (ADS)
Ninh, Chi Suze Q.
Endovascular embolization of intracranial aneurysms is a minimally invasive treatment in which an implanted material forms a clot to isolate the weakened vessel. Current strategy suffers from long-term potential failure modes. These potential failure modes include (1) enzymatic degradation of the fibrin clot that leads to compaction of the embolic agent, (2) incomplete filling of the aneurysm sac by embolic agent, and (3) challenging geometry of wide neck aneurysms. In the case of wide neck aneurysms, usually an assisting metal stent is used to help open the artery. However, metal stents with much higher modulus in comparison to the soft blood vessel can cause biocompatibilities issues in the long term such as infection and scarring. Motivated to solve these challenges associated with endovascular embolization, strategies to synthesize and engineer reconfigurable and biodegradable polymers as alternative therapies are evaluated in this thesis. (1) Reconfiguration of fibrin gel's modulus was achieved through crosslinking with genipin released from a biodegradable polymer matrix. (2) Reconfigurability can also be achieved by transforming triblock co-polymer hydrogel into photoresponsive material through incorporation of melanin nanoparticles as efficient photosensitizers. (3) Finally, reconfigurability can be conferred on biodegradable polyester networks via Diels-Alder coupling of furan pendant groups and dimaleimide crosslinking agent. Taken all together, this thesis describes strategies to transform a broad class of polymer networks into reconfigurable materials for improved treatment of intracranial aneurysms as well as for other biomedical applications.
Clinicopathologic Features and Results of Transcatheter Arterial Chemoembolization for Osteosarcoma
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chu Jianping; Chen Wei; Li Jiaping
2007-04-15
Purpose. To evaluate the effect of transcatheter arterial chemoembolization (TACE) for osteosarcoma and to describe the clinicopathologic features produced by TACE as well as the effect of different embolic materials. Methods. From January 1998 to December 2003, preoperative TACE was carried out in 32 patients. The preoperative and postoperative clinical response, levels of alkaline phosphatase (AKP), leukocyte count, and clinicopathologic features were recorded. We also compared the effect of different embolic materials: adriblastine gelatin microspheres, anhydrous alcohol, common bletilla tuber, and gelatin sponge particles. Results. The levels of AKP were significantly decreased after treatment (p < 0.05), but there wasmore » no significant difference in the leukocyte count. Large areas of necrosis were found histologically within 85.5% tumors after TACE. Embolic agents such as adriblastine microspheres, anhydrous alcohol, and common bletilla tuber have better clinical effects than gelatin sponge particles, but there was no significant difference among the first three embolic materials. After treatment, no serious complications were noted. During successful follow-up for 86 months, the survival rate after TACE at 1, 2, and 5 years was 95.5%, 72%, and 42% respectively. Conclusion. TACE accelerated tumor necrosis and shrank the tumor volume, thus making adequate tumor resection possible. The optimal time to operate is 10-14 days after TACE. TACE in combination with limb salvage surgery and postoperative periodical chemotherapy may be beneficial for increasing local control rates.« less
Giménez, Mariano E; Houghton, Eduardo J; Davrieux, C Federico; Serra, Edgardo; Pessaux, Patrick; Palermo, Mariano; Acquafresca, Pablo A; Finger, Caetano; Dallemagne, Bernard; Marescaux, Jacques
2018-03-01
When a major hepatic resection is necessary, sometimes the future liver remnant is not enough to maintain sufficient liver function and patients are more likely to develop liver failure after surgery. To test the hypothesis that performing a percutaneous radiofrecuency liver partition plus percutaneous portal vein embolization (PRALPPS) for stage hepatectomy in pigs is feasible. Four pigs (Sus scrofa domesticus) both sexes with weights between 25 to 35 kg underwent percutaneous portal vein embolization with coils of the left portal vein. By contrasted CT, the difference between the liver parenchyma corresponding to the embolized zone and the normal one was identified. Immediately, using the fusion of images between ultrasound and CT as a guide, radiofrequency needles were placed percutaneouslyand then ablated until the liver partition was complete. Finally, hepatectomy was completed with a laparoscopic approach. All animals have survived the procedures, with no reported complications. The successful portal embolization process was confirmed both by portography and CT. In the macroscopic analysis of the pieces, the depth of the ablation was analyzed. The hepatic hilum was respected. On the other hand, the correct position of the embolization material on the left portal vein could be also observed. "Percutaneous radiofrequency assisted liver partition with portal vein embolization" (PRALLPS) is a feasible procedure.
Utility and prevalence of imaging for underlying cancer in unprovoked pulmonary embolism.
Homewood, R; Medford, A R
2015-01-01
Current guidelines state that patients over 40 years of age with a first unprovoked pulmonary embolism should be offered limited screening for possible cancer and considered for intensive screening (abdomino-pelvic computed tomography and mammography), despite no evidence for the latter. The aim of this study was to evaluate the clinical utility and cost of intensive screening in routine clinical practice. Methods All patients diagnosed with a first unprovoked pulmonary embolism between January 2014 and June 2014 in a single large UK teaching hospital were included. The information management department searched for patients with an International Classification of Diseases 10 discharge diagnosis of pulmonary embolism and limited to 'acute pulmonary embolism with/without cor pulmonale'. Only patients with unprovoked pulmonary embolism were included. Patients with chronic medical conditions predisposing to pulmonary embolism were excluded. NHS costs were obtained from the Trust Finance Department. These costs were used to generate the costs of limited versus intensive screening, and then scaled up using adult population census information and assuming the same incidence of idiopathic pulmonary embolism to estimate the annual NHS cost of intensive screening. Results Ninety-two patients were diagnosed with pulmonary embolism, and 25 met the inclusion criteria. Clinical examination was often incomplete (84%). Limited screening was often missed (urinalysis 100%, serum calcium 64%). Intensive screening was performed in the majority of cases (68%, all abdomino-pelvic computed tomography with no cancer detected) with an £88 excess cost per patient. Conclusion Intensive screening in first unprovoked pulmonary embolism has a low yield, is costly and should not replace thorough clinical examination and basic screening.
Lu, Xiaojian; Hussain, Mohammed; Ni, Lanchun; Huang, Qinfeng; Zhou, Fei; Gu, Zhikai; Chen, Jian; Ding, Yuchuan; Xu, Feng
2014-01-01
Objective Transarterial treatment of direct carotid cavernous fistulas (DCCF) via embolic materials has been well documented. This study reports, validates, and compares with existing literature our experience treating DCCFs via endovascular approaches by using detachable balloons, coils, and covered stents. Methods Between June 2006 to October 2011, 32 patients (21 male, 11 female) with 32 DCCFs (30 traumatic, 2 spontaneous cavernous ICA aneurysms) were embolized endovascularly. Followup was performed for at least 6 months. Results Among the 32 DCCFs, 21 (65.6%) were embolized using detachable balloons, eight (25.0%) with coils, one (3.1%) with balloons and coils, and two (6.3%) with covered stents. Complete DCCF obliteration was achieved in 31 (96.9%) cases. One fistula failed to respond due to premature balloon detachment. Intracranial bruit in 31 (100%) chemosis and exophthalmos in 28 (100%) cases resolved after embolization. Visual acuity and oculomotor palsy improved in 18 (90%) and 18 (69.2%) cases, respectively. There was no evidence of DCCF recurrence. Thirteen DCCFs were followed up by MRI and five by DSA. In these cases, four (4/13, 30.8%) balloon-embolized DCCFs showed pseudoaneurysms. Three patients were asymptomatic; one had minor left oculomotor palsy. Conclusions Our results correlate and reinforce literature regarding endovascular treatment of DCCFs. Application of Transarterial embolization with detachable balloons, despite extensive use has been decreasing. Coil embolization is an effective and safe alternative for treatment, especially when balloon embolization fails. Covered stent placement may be used as another alternative for selected cases. PMID:25566340
Knipfer, Thorsten; Barrios-Masias, Felipe H; Cuneo, Italo F; Bouda, Martin; Albuquerque, Caetano P; Brodersen, Craig R; Kluepfel, Daniel A; McElrone, Andrew J
2018-05-30
A germplasm collection containing varied Juglans genotypes holds potential to improve drought resistance of plant materials for commercial production. We used X-ray computed microtomography to evaluate stem xylem embolism susceptibility/repair in relation to vessel anatomical features (size, arrangement, connectivity and pit characteristics) in 2-year-old saplings of three Juglans species. In vivo analysis revealed interspecific variations in embolism susceptibility among Juglans microcarpa, J. hindsii (both native to arid habitats) and J. ailantifolia (native to mesic habitats). Stem xylem of J. microcarpa was more resistant to drought-induced embolism as compared with J. hindsii and J. ailantifolia (differences in embolism susceptibility among older and current year xylem were not detected in any species). Variations in most vessel anatomical traits were negligible among the three species; however, we detected substantial interspecific differences in intervessel pit characteristics. As compared with J. hindsii and J. ailantifolia, low embolism susceptibility in J. microcarpa was associated with smaller pit size in larger diameter vessels, a smaller area of the shared vessel wall occupied by pits, lower pit frequency and no changes in pit characteristics as vessel diameters increased. Changes in amount of embolized vessels following 40 days of re-watering were minor in intact saplings of all three species highlighting that an embolism repair mechanism did not contribute to drought recovery. In conclusion, our data indicate that interspecific variations in drought-induced embolism susceptibility are associated with species-specific pit characteristics, and these traits may provide a future target for breeding efforts aimed at selecting walnut germplasm with improved drought resistance.
Embolization of peripheral high-flow arteriovenous malformations with Onyx.
Saeed Kilani, M; Lepennec, V; Petit, P; Magalon, G; Casanova, D; Bartoli, J-M; Vidal, V
2017-03-01
The aim of this study was to report our experience in embolization of high flow peripheral arteriovenous malformations (AVMs) with Onyx. Nineteen patients (10 men, 9 women) with peripheral high-flow AVMs who were treated with arteruial embolization using Onyx were retrospectively included. AVMs were located in the head and neck (6), extremities (5), chest (2), kidney (2), uterus (2), pelvis (1) and parietal (1). In 13 patients, embolization was done using Onyx only. One patient underwent embolization by direct puncture, the others by transarterial approach. Embolization was performed in one or multiple sessions (up to 5). A total of 28 sessions were performed. Follow-up was performed with a delay between 10 and 34 months. Technical success was achieved in all patients. Complete devascularization was obtained in 12 patients. Surgical excision was performed in 9 patients. Non-target Onyx embolization was not observed. One patient developed stroke. In 1 patient microcatheter fracture occured. One patient presented severe pain and bradycardia during the procedure that disappeared shortly after. One patient had persistent but less frequent epistaxis after embolization. Another patient had persistent pain without improvement. One patient was lost to follow-up. Other patients were free of symptoms on follow-up. Embolization with Onyx ® is an interesting option for management of peripheral high-flow AVMs either preoperatively or as a single treatment. Copyright © 2016 Éditions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Morshedi, Maud M., E-mail: maud.morshedi@my.rfums.org; Bauman, Michael, E-mail: mbauman@ucsd.edu; Rose, Steven C., E-mail: scrose@ucsd.edu
2015-04-15
PurposeSerious complications can result from nontarget embolization during yttrium-90 (Y-90) transarterial radioembolization. Hepatoenteric artery coil embolization has been traditionally performed to prevent nontarget radioembolization. The U.S. Food and Drug Administration–approved Surefire Infusion System (SIS) catheter, designed to prevent reflux, is an alternative to coils. The hypothesis that quantifiable SIS procedural parameters are comparable to coil embolization was tested.MethodsFourteen patients aged 36–79 years with colorectal, neuroendocrine, hepatocellular, and other predominantly bilobar hepatic tumors who underwent resin microsphere Y-90 radioembolization using only the SIS catheter (n = 7) versus only detachable coils (n = 7) for nontarget protection were reviewed retrospectively. Procedure time, fluoroscopy time, contrast dose,more » radiation dose, and cost were evaluated.ResultsMultivariate analysis identified significant cohort differences in the procedural parameters evaluated (F(10, 3) = 10.39, p = 0.04). Between-group comparisons of the pretreatment planning procedure in the SIS catheter group compared to the coil embolization group demonstrated a significant reduction in procedure time (102.6 vs. 192.1 min, respectively, p = 0.0004), fluoroscopy time (14.3 vs. 49.7 min, respectively, p = 0.0016), and contrast material dose (mean dose of 174.3 vs. 265.0 mL, respectively, p = 0.0098). Procedural parameters were not significantly different between the two groups during subsequent dose delivery procedures. Overall cost of combined first-time radioembolization procedures was significantly less in the SIS group ($4252) compared to retrievable coil embolization ($11,123; p = 0.001).ConclusionThe SIS catheter results in a reduction in procedure time, fluoroscopy time, and contrast material dose and may be an attractive cost-effective alternative to detachable coil embolization for prevention of nontarget radioembolization.« less
Brain embolic phenomena associated with cardiopulmonary bypass.
Challa, V R; Moody, D M; Troost, B T
1993-07-01
Various biologic and non-biologic materials may be embolized to the brain after the use of cardiopulmonary bypass (CPB) pumps during open heart surgery but their relative frequency and importance are uncertain. Among the nonbiologic materials, Antifoam A, which contains organosilicates and silicon, continues to be employed as an additive to prevent frothing. Recent improvements in filtration and oxygenation techniques have clearly reduced the incidence of large emboli and complications like stroke but other neurologic sequelae following open heart surgery are common and in many cases poorly explained. A recently developed histochemical technique for the demonstration of the endothelial alkaline phosphatase (AP) was employed in a post-mortem study of brains from 8 patients and 6 dogs dying within a few days after open heart surgery employing cardiopulmonary bypass perfusion. Brains from 38 patients and 6 dogs who were not subjected to heart surgery were studied as controls with the same technique. The AP-stained slides are suitable for both light microscopic examination of the thick celloidin sections as well as a subsequent processing for high-resolution microradiography. Small capillary and arteriolar dilatations (SCADs) were seen in the test subjects/animals but not controls. SCADs were seen in all parts of the brain. Approximately 50% of the SCADs showed birefringence when examined with polarized light. SCADs are putative embolic phenomena and the exact nature and source of the embolic material is under investigation. A glycolipid component is indicated by preliminary studies. SCADs are difficult to find in routine paraffin sections and most if not all of the offending material seems to be dissolved during processing.(ABSTRACT TRUNCATED AT 250 WORDS)
Orcutt, Sonia T.; Kobayashi, Katsuhiro; Sultenfuss, Mark; Hailey, Brian S.; Sparks, Anthony; Satpathy, Bighnesh; Anaya, Daniel A.
2016-01-01
Preoperative portal vein embolization (PVE) is used to extend the indications for major hepatic resection, and it has become the standard of care for selected patients with hepatic malignancies treated at major hepatobiliary centers. To date, various techniques with different embolic materials have been used with similar results in the degree of liver hypertrophy. Regardless of the specific strategy used, both surgeons and interventional radiologists must be familiar with each other’s techniques to be able to create the optimal plan for each individual patient. Knowledge of the segmental anatomy of the liver is paramount to fully understand the liver segments that need to be embolized and resected. Understanding the portal vein anatomy and the branching variations, along with the techniques used to transect the portal vein during hepatic resection, is important because these variables can affect the PVE procedure and the eventual surgical resection. Comprehension of the advantages and disadvantages of approaches to the portal venous system and the various embolic materials used for PVE is essential to best tailor the procedures for each patient and to avoid complications. Before PVE, meticulous assessment of the portal vein branching anatomy is performed with cross-sectional imaging, and embolization strategies are developed based on the patient’s anatomy. The PVE procedure consists of several technical steps, and knowledge of these technical tips, potential complications, and how to avoid the complications in each step is of great importance for safe and successful PVE and ultimately successful hepatectomy. Because PVE is used as an adjunct to planned hepatic resection, priority must always be placed on safety, without compromising the integrity of the future liver remnant, and close collaboration between interventional radiologists and hepatobiliary surgeons is essential to achieve successful outcomes. PMID:27014696
[Feasibility and efficiency of embolization of spinal dural arteriovenous fistula].
Zhang, Hong-qi; Liu, Jiang; Wang, Jian-sheng; Zhi, Xing-long; Zhang, Peng; Bian, Li-song; He, Chuan; Ye, Ming; Wang, Zhi-chao; Li, Meng; Ling, Feng
2013-03-01
To evaluate the feasibility and efficiency of embolization of spinal dural arteriovenous fistula (SDAVF). From December 2010 to May 2012, there were 104 cases of SDAVF were treated, and 26 cases were selected to be treated with embolization. The inclusion criteria was as follows: (1) No anterior or posterior spinal artery originated from the fistula segment; (2) The segmental artery can be catheterized with guiding or micro catheter; (3) High flow in fistula; (4) Patient's situation was not suitable for surgery or general anesthesia. Among 26 cases, there were 22 male and 4 female patients, the average age was 55.9 years (ranged from 34 to 81 years). The locations of SDAVF were 10 cases in thoracic, 9 in lumbar and 7 in sacral segment. The main symptoms were progressive numbness and weakness in both lower extremities, most cases accompanied with difficulties in urination and defecation. The average history was 17.1 months (from 1 to 156 months). ONYX-18 liquid embolic agent or Glubran-2 surgical glue were used as embolic material. The patients not cured with embolization were treated with surgery in the following 1 - 2 weeks. Follow-up evaluation was done with MRI after 3 months and DSA after 6 months, besides physical examination. Fifteen from 26 cases achieved immediate angiographic cure results: 14 in 20 cases which embolized with ONYX-18; only 1 in 6 cases with Glubran-2. Three in 10 cases of thoracic SDAVF and 12 in 16 cases of lumbar/sacral SDAVF were cured with embolization. Partially embolized cases were treated with surgical obliteration of drainage veins within 2 weeks. Cured patients experienced immediate improvement after embolization and kept getting better in the follow-up. All the patients had MRI follow-up after 3 months and DSA follow-up after 6 months. In 6 month's follow-up, MRI showed the edema and flow void signal in the spinal cord disappeared. DSA showed no fistula recurrence or remnant. There was no deterioration case in all of the embolized cases. Particular SDAVF is suitable for embolization with ONYX-18. Most lesions located in lumbar and sacral segment are good indications for embolization.
Onyx embolization with the Apollo detachable tip microcatheter: A single-center experience.
Miller, Timothy R; Giacon, Luciano; Kole, Matthew J; Chen, Rong; Jindal, Gaurav; Gandhi, Dheeraj
2018-06-01
Purpose The Apollo Onyx Delivery Microcatheter (Ev3, Irvine, CA) is a detachable-tip microcatheter that was developed to reduce the risk of microcatheter entrapment during ethylene-vinyl alcohol copolymer (Onyx) embolizations. We report our experience with the microcatheter in a variety of neurointerventional procedures. Methods We retrospectively reviewed all Onyx embolizations performed in the head, neck, and spine using the Apollo Onyx Delivery Microcatheter from its introduction at our institution in July 2014 to August 2016. Information regarding patient diagnoses, procedural details, as well as clinical outcomes were obtained from the electronic medical record, procedure reports, and relevant angiographic imaging. Results A total of 58 arterial pedicle Onyx embolizations were performed in 37 patients. There were no cases of microcatheter entrapment, early/inadvertent tip detachment, or vessel injury upon removal of the device. There were two instances (3.5%) of leakage of Onyx from the microcatheter detachment site during embolization, which did not result in adverse sequelae. Clinical outcomes were excellent, with nearly all embolizations achieving the intended goal. In multivariate analysis, length of Onyx reflux along the microcatheter tip and utilization of a higher viscosity agent, Onyx 34, were significantly associated with tip detachment. Conclusion The use of the Apollo Microcatheter is both safe and effective during neurointerventional embolizations using Onyx. Leakage of liquid embolic agent from the detachment site is an infrequent technical complication that may be encountered with the device.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nevala, Terhi, E-mail: Terhi.Nevala@ppshp.f; Biancari, Fausto; Manninen, Hannu
2010-04-15
The purpose of this study was to report our experience in treating type II endoleaks after endovascular aneurysm repair (EVAR) of abdominal aortic aneurysms. Two hundred eighteen patients underwent EVAR with a Zenith stent-graft from January 2000 to December 2005. During a follow-up period of 4.5 {+-} 2.3 years, solely type II endoleak was detected in 47 patients (22%), and 14 of them underwent secondary interventions to correct this condition. Ten patients had transarterial embolization, and four patients had translumbar/transabdominal embolization. The embolization materials used were coils, thrombin, gelatin, Onyx (ethylene-vinyl alcohol copolymer), and glue. Disappearance of the endoleak withoutmore » enlargement of the aneurysm sac after the first secondary intervention was achieved in only five of these patients (5/13). One patient without surveillance imaging was excluded from analyses of clinical success. After additional interventions in four patients and the spontaneous disappearance of type II endoleak in two patients, overall clinical success was achieved in eight patients (8/12). One patient did not have surveillance imaging after the second secondary intervention. Clinical success after the first secondary intervention was achieved in two patients (2/9) in the transarterial embolization group and three patients (3/4) in the translumbar embolization group. The results of secondary interventions for type II endoleak are unsatisfactory. Although the small number of patients included in this study prevents reliable comparisons between groups, the results seem to favor direct translumbar embolization in comparison to transarterial embolization.« less
[Selective embolization to treat obstetric hemorrhage].
Ferrer Puchol, M D; Lanciego, C; Esteban, E; Ciampi, J J; Edo, M A; Ferragud, S
2014-01-01
To describe cases of obstetric hemorrhage that have called for selective intra-arterial embolization and the different embolization techniques used. To assess the clinical outcomes and postprocedural fertility. We studied 27 women with obstetric hemorrhage. In 24 patients, embolization was performed by catheterizing both uterine arteries and in 2 patients only one uterine artery was catheterized (pseudoaneurysm). The materials used for embolization consisted of Spongostan in 17/27, particles in 9/27, and coils in 1/27. Clinical follow-up included an analysis of early and late complications and of postprocedural fertility. Hemorrhage was classified as primary (25/27) or secondary (2/27). The cause of bleeding was vaginal delivery (20), cesarean sections (5), abortion (1), and cervical ectopic pregnancy (1). The initial technical success rate was 100% and the clinical success rate was 92.6% (25 of the 27 patients). Bleeding ceased and the outcome was satisfactory in 25 patients. During clinical follow-up ranging from one to seven years, 23 patients had normal menstruation and 6 patients completed 7 full-term pregnancies. Intra-arterial embolization for obstetric hemorrhage leads to good outcomes and few complications and it preserves fertility. Copyright © 2011 SERAM. Published by Elsevier Espana. All rights reserved.
Arterial Embolization in the Management of Mesenteric Bleeding Secondary to Blunt Abdominal Trauma
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ghelfi, Julien, E-mail: JGhelfi@chu-grenoble.fr; Frandon, Julien, E-mail: JFrandon2@chu-grenoble.fr; Barbois, Sandrine, E-mail: SBarbois@chu-grenoble.fr
IntroductionMesenteric bleeding is a rare but potentially life-threatening complication of blunt abdominal trauma. It can induce active hemorrhage and a compressive hematoma leading to bowel ischemia. Emergency laparotomy remains the gold standard treatment. We aimed to study the effectiveness and complications of embolization in patients with post-traumatic mesenteric bleeding.Materials and MethodsThe medical records of 7 consecutive patients with active mesenteric bleeding treated by embolization in a level-one trauma center from 2007 to 2014 were retrospectively reviewed. All patients presented with active mesenteric bleeding on CT scans without major signs of intestinal ischemia. We focused on technical success, clinical success, andmore » the complications of embolization.ResultsSix endovascular procedures were successful in controlling hemorrhage but 1 patient had surgery to stop associated arterial and venous bleeding. One patient suffered from bowel ischemia, a major complication of embolization, which was confirmed by surgery. No acute renal failure was noted after angiography. For 1 patient we performed combined management as the endovascular approach allowed an easier surgical exploration.ConclusionIn mesenteric trauma with active bleeding, embolization is a valuable alternative to surgery and should be considered, taking into account the risk of bowel ischemia.« less
Effect of Embolization Material in the Calculation of Dose Deposition in Arteriovenous Malformations
DOE Office of Scientific and Technical Information (OSTI.GOV)
De la Cruz, O. O. Galvan; Moreno-Jimenez, S.; Larraga-Gutierrez, J. M.
2010-12-07
In this work it is studied the impact of the incorporation of high Z materials (embolization material) in the dose calculation for stereotactic radiosurgery treatment for arteriovenous malformations. A statistical analysis is done to establish the variables that may impact in the dose calculation. To perform the comparison pencil beam (PB) and Monte Carlo (MC) calculation algorithms were used. The comparison between both dose calculations shows that PB overestimates the dose deposited. The statistical analysis, for the quantity of patients of the study (20), shows that the variable that may impact in the dose calculation is the volume of themore » high Z material in the arteriovenous malformation. Further studies have to be done to establish the clinical impact with the radiosurgery result.« less
[Embolization of the uterine artery in the treatment of uterine myoma].
Simonetti, G; Romanini, C; Pocek, M; Piccione, E; Guazzaroni, M; Zupi, E; Gandini, R; Gabriele, A; Vaquero, E
2001-03-01
To propose uterine myoma embolization as an alternative to myomectomy or hysterectomy in the treatment of symptomatic myomas; to evaluate the efficacy of the procedure in terms of clinical outcome, adopting all procedural and technical precautions to ensure minimal X-ray exposure and preserve reproductive potential. Between April 1998 and February 2000, 26 patients, age range 32-54 years (mean 41 years), underwent uterine arterial embolization for menorrhagia, pelvic pain, and sensation of mass and pressure. Inclusion criteria were: single myomas, intramural localization and rich vascolarization of the lesion. Dose to patient was obtained by placing a thermoluminescent dosimeter (Harshaw, Solon, Ohio) both placed in posterior fornix of the vagina and on the skin at the beam entrance site. The procedure was performed under peridural anesthesia; polyvinil alcohol particles 355-500 mu (Contour) (Target Therapeutics, Boston Scientific Corporation, Fremont CA, USA) were employed as embolic agent. The uterine arteries were incannulated with a 5F (Glidecath, Terumo, Europe NV, Belgium) and successively 3F coaxial microcatheter (Target, Boston Scientific Corporation, Fremont CA, USA); the embolic material was injected as distally as possible. Color Power Doppler Ultrasound follow-up before and after i.v. contrast media administration (Levovist SHU 508 A, Shering, Berlin, Germany) was carried out at 15 days, at 1, at 3, at 6 months, and at 1 year from embolization. Pre-procedural evaluation and follow-up at 1 year was performed by MRI using T1 and T2 weighted images before and after Gadolinium (GdDTPA Shering, Berlin, Germany) administration. The technical success of the interventional procedure was 100% (26/26 cases). The mean fluoroscopy time was 20 minutes, and the mean number of angiographic exposures was 10. The mean estimated ovarian dose was 18.75 cGy and the mean adsorbed skin dose was 126.71 cGy. The imaging follow-up showed a 55% reduction of myoma volume at 6 months and a 75% reduction at 1 year. All patients reported a marked decrease in symptoms. No major complications were observed. The appearance of pelvic pain in the 24-48 hours after the procedure required sedation by analgesic pump; transitorial amenorrhea was observed in 3 patients. As for term complications, 2 patients have eliminated necrotic material through the vagina four weeks after procedure. The patients reported great satisfaction with the procedure. Many treatment options are currently available for symptomatic uterine myomas. One is surgical myomectomy which is associated with increased blood loss, pain and post operative morbidity and requires an additional surgical procedure for fibroma recurrence in 20-25% of patients. Another alternative treatment is hormonal therapy, which drammatically improves symptoms and reduces fibroid size although leiomyomas regrow to their original size within a few months of discontinuing treatment. Uterine embolization is a relatively new treatment for uterine fibroids that can be considered as an alternative to surgical and medical procedures. The radiation exposure adsorbed by the patient is reduced by using pulsed fluoroscopy and taking all the precautionary measures required to minimize the dose. The technical success, the patient' satisfation, the short hospitalization time and preservation of fertility confer to uterine artery embolization the role of a new alternative therapy for the treatment of symptomatic uterine myomas.
Perfusion defects in pulmonary perfusion iodine maps: causes and semiology.
Bustos Fiore, A; González Vázquez, M; Trinidad López, C; Mera Fernández, D; Costas Álvarez, M
2017-12-14
to describe the usefulness of dual-energy CT for obtaining pulmonary perfusion maps to provide morphological and functional information in patients with pulmonary embolisms. To review the semiology of perfusion defects due to pulmonary embolism so they can be differentiated from perfusion defects due to other causes: alterations outside the range used in the iodine map caused by other diseases of the lung parenchyma or artifacts. CT angiography of the pulmonary arteries is the technique of choice for the diagnosis of pulmonary embolisms. New dual-energy CT scanners are useful for detecting perfusion defects secondary to complete or partial obstruction of pulmonary arteries and is most useful for detecting pulmonary embolisms in subsegmental branches. Copyright © 2017 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.
Cressman, Erik N K; Guo, Chunxiao
2018-06-05
Embolotherapies are commonly used for management of primary liver cancer. Explant studies of treated livers, however, reveal an untreated tumor in a high fraction of cases. To improve on this, we propose a new concept referred to as thermoembolization. In this technique, the embolic material reacts in local tissues. Highly localized heat energy is released simultaneously with the generation of acid in the target vascular bed. Combined with ischemia, this should provide a multiplexed attack. We report herein our initial results testing the feasibility of this method in vivo. Institutional approval was obtained, and three outbred swine were treated in a segmental hepatic artery branch (right or left medial lobe) with thermoembolic material (100, 400, or 500 µL). Solutions (2 or 4 mol/L) of an acid chloride were made using ethiodized oil as the vehicle. Animals were housed overnight, scanned by CT, and euthanized. Necropsy samples of treated tissue were obtained for histologic analysis. All animals survived the procedure. Vascular stasis occurred rapidly in all cases despite the small volumes used. The lower concentration (2 mol/L) penetrated more distally than the 4 mol/L solution. At CT the following day, vascular casts of ethiodized oil were observed, indicating recanalization had not occurred. Histology specimens demonstrated coagulative necrosis centered on the vessel lumen extending for several hundred microns with a peripheral inflammatory infiltrate. Thermoembolization is a new technique for embolization with initial promise. However, results indicate much work must be done to optimize the technique.
Wu, Huawei; Zhang, Qing; Hua, Jia; Hua, Xiaolan; Xu, Jianrong
2013-01-01
Background The aim of this study was to determine the optimal monochromatic spectral CT pulmonary angiography (sCTPA) levels to obtain the highest image quality and diagnostic confidence for pulmonary embolism detection. Methods The Institutional Review Board of the Shanghai Jiao Tong University School of Medicine approved this study, and written informed consent was obtained from all participating patients. Seventy-two patients with pulmonary embolism were scanned with spectral CT mode in the arterial phase. One hundred and one sets of virtual monochromatic spectral (VMS) images were generated ranging from 40 keV to 140 keV. Image noise, clot diameter and clot to artery contrast-to-noise ratio (CNR) from seven sets of VMS images at selected monochromatic levels in sCTPA were measured and compared. Subjective image quality and diagnostic confidence for these images were also assessed and compared. Data were analyzed by paired t test and Wilcoxon rank sum test. Results The lowest noise and the highest image quality score for the VMS images were obtained at 65 keV. The VMS images at 65 keV also had the second highest CNR value behind that of 50 keV VMS images. There was no difference in the mean noise and CNR between the 65 keV and 70 keV VMS images. The apparent clot diameter correlated with the keV levels. Conclusions The optimal energy level for detecting pulmonary embolism using dual-energy spectral CT pulmonary angiography was 65–70 keV. Virtual monochromatic spectral images at approximately 65–70 keV yielded the lowest image noise, high CNR and highest diagnostic confidence for the detection of pulmonary embolism. PMID:23667583
Chitosan-Based Multifunctional Platforms for Local Delivery of Therapeutics
Hong, Seong-Chul; Yoo, Seung-Yup; Kim, Hyeongmin; Lee, Jaehwi
2017-01-01
Chitosan has been widely used as a key biomaterial for the development of drug delivery systems intended to be administered via oral and parenteral routes. In particular, chitosan-based microparticles are the most frequently employed delivery system, along with specialized systems such as hydrogels, nanoparticles and thin films. Based on the progress made in chitosan-based drug delivery systems, the usefulness of chitosan has further expanded to anti-cancer chemoembolization, tissue engineering, and stem cell research. For instance, chitosan has been used to develop embolic materials designed to efficiently occlude the blood vessels by which the oxygen and nutrients are supplied. Indeed, it has been reported to be a promising embolic material. For better anti-cancer effect, embolic materials that can locally release anti-cancer drugs were proposed. In addition, a complex of radioactive materials and chitosan to be locally injected into the liver has been investigated as an efficient therapeutic tool for hepatocellular carcinoma. In line with this, a number of attempts have been explored to use chitosan-based carriers for the delivery of various agents, especially to the site of interest. Thus, in this work, studies where chitosan-based drug delivery systems have successfully been used for local delivery will be presented along with future perspectives. PMID:28257059
Odat, Haitham; Alawneh, Khaled; Al-Qudah, Mohannad
2018-01-01
Jugular paragangliomas are slow growing highly vascular tumors arising from jugular paraganglia. The gold standard of treatment is complete surgical resection. Pre-operative embolization of these highly vascular tumors is essential to reduce intra-operative bleeding, allow safe dissection, and decrease operative time and post-operative complications. Onyx (ethylene-vinyl alcohol copolymer) has been widely used as permanent occluding material for vascular tumors of skull base because of its unique physical properties. We present the case of a 33-year-old woman who had left-sided facial nerve paralysis after Onyx embolization of jugular paraganglioma. The tumor was resected on the next day of embolization. The patient was followed up for 30 months with serial imaging studies and facial nerve assessment. The facial verve function improved from House–Brackmann grade V to grade II at the last visit. PMID:29518926
Odat, Haitham; Alawneh, Khaled; Al-Qudah, Mohannad
2018-03-07
Jugular paragangliomas are slow growing highly vascular tumors arising from jugular paraganglia. The gold standard of treatment is complete surgical resection. Pre-operative embolization of these highly vascular tumors is essential to reduce intra-operative bleeding, allow safe dissection, and decrease operative time and post-operative complications. Onyx (ethylene-vinyl alcohol copolymer) has been widely used as permanent occluding material for vascular tumors of skull base because of its unique physical properties. We present the case of a 33-year-old woman who had left-sided facial nerve paralysis after Onyx embolization of jugular paraganglioma. The tumor was resected on the next day of embolization. The patient was followed up for 30 months with serial imaging studies and facial nerve assessment. The facial verve function improved from House-Brackmann grade V to grade II at the last visit.
Techniques for Intravascular Foreign Body Retrieval
DOE Office of Scientific and Technical Information (OSTI.GOV)
Woodhouse, Joe B.; Uberoi, Raman, E-mail: raman.uberoi@orh.nhs.uk
2013-08-01
As endovascular therapies increase in frequency, the incidence of lost or embolized foreign bodies is increasing. The presence of an intravascular foreign body (IFB) is well recognized to have the potential to cause serious complications. IFB can embolize and impact critical sites such as the heart, with subsequent significant morbidity or mortality. Intravascular foreign bodies most commonly result from embolized central line fragments, but they can originate from many sources, both iatrogenic and noniatrogenic. The percutaneous approach in removing an IFB is widely perceived as the best way to retrieve endovascular foreign bodies. This minimally invasive approach has a highmore » success rate with a low associated morbidity, and it avoids the complications related to open surgical approaches. We examined the characteristics, causes, and incidence of endovascular embolizations and reviewed the various described techniques that have been used to facilitate subsequent explantation of such materials.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baek, Yoolim; Won, Je Hwan; Kong, Tae-Wook
PurposeTo analyze imaging findings of lymphatic leakage associated with surgical lymph node dissection on lymphangiography and assess the outcome of lymphatic embolization.Materials and MethodsThis retrospective study comprised 21 consecutive patients who were referred for lymphatic intervention between March 2014 and April 2015 due to postsurgical lymphatic leaks. Lymphangiography was performed through inguinal lymph nodes to identify the leak. When a leak was found, lymphatic embolization was performed by fine-needle injection of N-butyl cyanoacrylate into the site of leakage or into an inflow lymphatic vessel or into a pelvic lymph node located below the leakage. Electronic medical records and imaging studiesmore » were reviewed to assess the outcome.ResultLymphangiography revealed single or multiple leaks in all but one patient. Lymphatic embolization was performed in 20 patients with leaks. Including the patient who did not undergo embolization, 17 patients (81.0 %) showed initial response to treatment. Three patients underwent repeated embolization with successful results. The overall success rate was 95.2 %. The mean duration of hospitalization after lymphatic intervention was 5.9 days. During a mean follow-up period of 11 months, two patients developed localized swelling in the groin following lipiodol injection. There were no complications related to lymphatic embolization. Three patients were found to have developed small, asymptomatic lymphoceles on CT or MRI that did not require further treatment.ConclusionLymphangiography is useful for detecting lymphatic leakage occurring after lymph node dissection. Furthermore, lymphatic embolization is feasible, effective, and safe for managing leaks demonstrated on lymphangiography.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vilas Boas, P. P.; Castro-Afonso, L. H. de; Monsignore, L. M.
PurposeAcute hemorrhage associated with cancers of the head and neck is a life-threatening condition that requires immediate action. The aim of this study was to assess the safety and efficacy of endovascular embolization for acute hemorrhage in patients with head and neck cancers.Materials and MethodsData were retrospectively collected from patients with head and neck cancers who underwent endovascular embolization to treat acute hemorrhage. The primary endpoint was the rate of immediate control of hemorrhage during the first 24 h after embolization. The secondary endpoints were technical or clinical complications, rate of re-hemorrhage 24 h after the procedure, time from embolization to re-hemorrhage,more » hospitalization time, mortality rate, and time from embolization to death.ResultsFifty-one patients underwent endovascular embolization. The primary endpoint was achieved in 94% of patients. The rate of technical complications was 5.8%, and no clinical complication was observed. Twelve patients (23.5%) had hemorrhage recurrence after an average time of 127.5 days. The average hospitalization time was 7.4 days, the mortality rate during the follow-up period was 66.6%, and the average time from embolization to death was 132.5 days.ConclusionEndovascular embolization to treat acute hemorrhage in patients with head and neck cancers is a safe and effective method for the immediate control of hemorrhage and results in a high rate of hemorrhage control. Larger studies are necessary to determine which treatment strategy is best for improving patient outcomes.« less
Bronchial Artery Aneurysm Embolization with NBCA
DOE Office of Scientific and Technical Information (OSTI.GOV)
Aburano, Hiroyuki, E-mail: aburano-3@r.vodafone.ne.jp; Kawamori, Yasuhiro; Horiti, Yasushi
2006-12-15
We present a case of asymptomatic bronchial artery aneurysm that formed a fistula with part of the pulmonary artery (there was no definite fistula with the pulmonary vein). We were able to catheterize the feeding vessel but could not reach the aneurysm. We therefore injected a mixture of N-butyl-2-cyanoacrylate (NBCA; Histoacryl, B. Braun, Melsungen, Germany) and iodized oil (Lipiodol; Guerbet, Aulnay-sous-Bois, France) from the feeding vessel. The fistula, aneurysm, and feeding vessel were almost totally occluded. After embolization, the patient coughed a little; there were no other definite side effects or complications. One and 3 months later, on chest CT,more » the aneurysm was almost completely occupied with hyperattenuating NBCA-Lipiodol embolization. NBCA is a liquid embolization material whose time to coagulation after injection can be controlled by diluting it with Lipiodol. It is therefore possible to embolize an aneurysm, feeding vessels, and efferent vessels (in our case, it was a fistula) by using an NBCA-Lipiodol mixture of an appropriate concentration, regardless of whether the catheter can reach the aneurysm or not.« less
Embolization of Isolated Lumbar Artery Injuries in Trauma Patients
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sofocleous, Constantinos T., E-mail: constant@pol.net; Hinrichs, Clay R.; Hubbi, Basil
Purpose. The purpose of the study was to evaluate the angiographic findings and results of embolotherapy in the management of lumbar artery trauma. Methods. All patients with lumbar artery injury who underwent angiography and percutaneous embolization in a state trauma center within a 10-year period were retrospectively reviewed. Radiological information and procedural reports were reviewed to assess immediate angiographic findings and embolization results. Long-term clinical outcome was obtained by communication with the trauma physicians as well as with chart review. Results. In a 10-year period, 255 trauma patients underwent abdominal aortography. Eleven of these patients (three women and eight men)more » suffered a lumbar artery injury. Angiography demonstrated active extravasation (in nine) and/or pseudoaneurysm (in four). Successful selective embolization of abnormal vessel(s) was performed in all patients. Coils were used in six patients, particles in one and gelfoam in five patients. Complications included one retroperitoneal abscess, which was treated successfully. One patient returned for embolization of an adjacent lumbar artery due to late pseudoaneurysm formation. Conclusions. In hemodynamically stable patients, selective embolization is a safe and effective method for immediate control of active extravasation, as well as to prevent future hemorrhage from an injured lumbar artery.« less
Refractory Gastrointestinal Bleeding: Role of Angiographic Intervention
2013-01-01
Although endoscopic hemostasis remains initial treatment modality for nonvariceal gastrointestinal (GI) bleeding, severe bleeding despite endoscopic management occurs in 5% to 10% of the patients, requiring surgery or transcatheter arterial embolization (TAE). TAE is now considered the first-line therapy for massive GI bleeding refractory to endoscopic management. GI endoscopists need to be familiar with indications, principles, outcomes, and complications of TAE, as well as embolic materials available. PMID:24143308
Wang, Weixiong; Graziano, Francesca; Russo, Vittorio; Ulm, Arthur J; De Kee, Daniel; Khismatullin, Damir B
2013-01-01
The endovascular treatment of intracranial aneurysms remains a challenge, especially when the aneurysm is large in size and has irregular, non-spherical geometry. In this paper, we use computational fluid dynamics to simulate blood flow in a vertebro-basilar junction giant aneurysm for the following three cases: (1) an empty aneurysm, (2) an aneurysm filled with platinum coils, and (3) an aneurysm filled with a yield stress fluid material. In the computational model, blood and the coil-filled region are treated as a non-Newtonian fluid and an isotropic porous medium, respectively. The results show that yield stress fluids can be used for aneurysm embolization provided the yield stress value is 20 Pa or higher. Specifically, flow recirculation in the aneurysm and the size of the inflow jet impingement zone on the aneurysm wall are substantially reduced by yield stress fluid treatment. Overall, this study opens up the possibility of using yield stress fluids for effective embolization of large-volume intracranial aneurysms.
Transcatheter arterial embolization of acute gastrointestinal tumor hemorrhage with Onyx.
Sun, C J; Wang, C E; Wang, Y H; Xie, L L; Liu, T H; Ren, W C
2015-02-01
Endovascular embolization has been used to control gastrointestinal tumor bleeding. Lots of embolic agents have been applied in embolization, but liquid embolic materials such as Onyx have been rarely used because of concerns about severe ischemic complications. To evaluate the clinical efficacy and safety of transcatheter arterial embolization (TAE) with Onyx for acute gastrointestinal tumor hemorrhage. Between September 2011 and July 2013, nine patients were diagnosed as acute gastrointestinal tumor hemorrhage by clinical feature and imaging examination. The angiographic findings were extravasation of contrast media in the five patients. The site of hemorrhage included upper gastrointestinal bleeding in seven cases and lower gastrointestinal bleeding in two cases. TAE was performed using Onyx in all the patients, and the blood pressure and heart rate were monitored, the angiographic and clinical success rate, recurrent bleeding rate, procedure related complications and clinical outcomes were evaluated after therapy. The clinical parameters and embolization data were studied retrospectively. All the patients (100%) who underwent TAE with Onyx achieved complete hemostasis without rebleeding and the patients were discharged after clinical improvement without a second surgery. No one of the patients expired during the hospital course. All the patients were discharged after clinical improvement without a second surgery. Postembolization bowel ischemia or necrosis was not observed in any of the patients who received TAE with Onyx. TAE with Onyx is a highly effective and safe treatment modality for acute gastrointestinal tumor hemorrhage, even with pre-existing coagulopathy.
1977-09-30
90F ork Unit No. 76/24 (FY76, 0) An Investination of the Effect of Supplemental Oxygen on Chemically Induced Fat Embolization ...accepted as criteria for determination of the presence of fat embolism syndrome. In this study laboratory parameters and lung scans are obtained for a 5...91 Work Unit No. 76/31 (FY76, 0) Early Detection of Fatiaue Fracture by Bone Scannina with Tc-99 Bone Scan Agents
Tandberg, Daniel J; Smith, Tony P; Suhocki, Paul V; Pabon-Ramos, Waleska; Nelson, Rendon C; Desai, Svetang; Branch, Stanley; Kim, Charles Y
2012-11-01
To report short-term results of empiric transcatheter embolization for patients with advanced malignancy and gastrointestinal (GI) hemorrhage directly from a tumor invading the GI tract wall. Between 2005 and 2011, 37 mesenteric angiograms were obtained in 26 patients with advanced malignancy (20 men, six women; mean age, 56.2 y) with endoscopically confirmed symptomatic GI hemorrhage from a tumor invading the GI tract wall. Angiographic findings and clinical outcomes were retrospectively evaluated. Clinical success was defined as absence of signs and symptoms of hemorrhage for at least 30 day following embolization. Active extravasation was demonstrated in three cases. Angiographic abnormalities related to a GI tract tumor were identified on 35 of 37 angiograms, including tumor neovascularity (n = 21), tumor enhancement (n = 24), and luminal irregularity (n = 5). In the absence of active extravasation, empiric embolization with particles and/or coils was performed in 25 procedures. Cessation of hemorrhage (ie, clinical success) occurred more frequently when empiric embolization was performed (17 of 25 procedures; 68%) than when embolization was not performed (two of nine; 22%; P = .03). Empiric embolization resulted in clinical success in 10 of 11 patients with acute GI bleeding (91%), compared with seven of 14 patients (50%) with chronic GI bleeding (P = .04). No ischemic complications were encountered. In patients with advanced malignancy, in the absence of active extravasation, empiric transcatheter arterial embolization for treatment of GI hemorrhage from a direct tumor source demonstrated a 68% short-term success rate, without any ischemic complications. Copyright © 2012 SIR. Published by Elsevier Inc. All rights reserved.
Shape memory polymer (SMP) gripper with a release sensing system
Maitland, Duncan J.; Lee, Abraham P.; Schumann, Daniel L.; Silva, Luiz Da
2000-01-01
A system for releasing a target material, such as an embolic coil from an SMP located at the end of a catheter utilizing an optical arrangement for releasing the material. The system includes a laser, laser driver, display panel, photodetector, fiber optics coupler, fiber optics and connectors, a catheter, and an SMP-based gripper, and includes a release sensing and feedback arrangement. The SMP-based gripper is heated via laser light through an optic fiber causing the gripper to release a target material (e.g., embolic coil for therapeutic treatment of aneurysms). Various embodiments are provided for coupling the laser light into the SMP, which includes specific positioning of the coils, removal of the fiber cladding adjacent the coil, a metal coating on the SMP, doping the SMP with a gradient absorbing dye, tapering the fiber optic end, coating the SMP with low refractive index material, and locating an insert between the fiber optic and the coil.
Clarençon, Frédéric; Di Maria, Federico; Gabrieli, Joseph; Carpentier, Alexandre; Pistochi, Silvia; Bartolini, Bruno; Zeghal, Chiheb; Chiras, Jacques; Sourour, Nader-Antoine
2016-10-01
Transverse-sigmoid dural arteriovenous fistulas (TS DAVFs) can be challenging to treat by endovascular means. Indeed, a total cure of the fistula can only be achieved when complete occlusion of the fistulous point(s) is obtained by penetration of the embolic agent. However, in some cases, especially for transosseous branches from extracranial arteries like the occipital artery (OcA) or the superficial temporal artery (STA), such penetration is usually poor, leading to major proximal reflux and incomplete fistula obliteration. We present three cases of embolization in two patients with TS DAVF through the OcA and/or the STA with Onyx® using a double-lumen balloon (Microvention, Tustin, CA, USA). This technique allows the penetration of the embolic agent in the transosseous branches by forming a counter-pressure with the inflated balloon. This technique may be useful to achieve complete occlusion of TS DAVFs by endovascular means.
Nakahara, T.; Sakamoto, S.; Hamasaki, O.; Sakoda, K.
2003-01-01
Summary We report the histological findings in two patients treated using Guglielmi detachable coils with almost complete occlusion of the aneurysms. Autopsies of these patients were performed one week and one year after GDC embolization respectively. In one aneurysm that was obtained at autopsy one week after embolization, the histological findings revealed coils and an unorganized thrombus-filled aneurysm sac; an incomplete cell-lining on the luminal side of fibrin thrombi in the region of the neck of the aneurysm was recognized. In the other aneurysm in which autopsy was performed one year after embolization, an organized fibrous tissue at the margin of the aneurysmal wall and vascular granulation tissue at the center of the aneurysm were observed. There is a single layer of endothelium covering fibrous tissue in the neck of the aneurysm. We discuss the healing process after GDC treatment. PMID:20591231
Sato, Tetsu; Marubashi, Shigeru; Kenjo, Akira; Tsuchiya, Takao; Kimura, Takashi; Sato, Naoya; Watanabe, Junichiro; Tasaki, Kazuhiro; Hashimoto, Yuko; Wada, Ikuo; Gotoh, Mitsukazu
2016-05-01
The mechanism of anti-tumor effect of transarterial Immuno-Embolization (TIE) using OK-432 has not been well elucidated. In this study, we aimed to investigate the tissue injury and immune response after portal venous embolization (PVE) with/without OK-432. Embolic materials (L group: lipiodol, LF group: lipiodol+fibrinogen, LO group: lipiodol+OK-432, LFO group: lipiodol+fibrinogen+OK-432) were administered via the right portal vein in Wistar rats. The histological findings in LFO group demonstrated liver damage with severe architectural changes. The concentrations of CD68(+) cells were observed in a time-dependent manner; it was significantly increased in the LO group on day 1 and in the LFO group on day 3. CD68(+)CD163(-) macrophages significantly increased in the LFO group on day 7 (P<0.05). In conclusion, PVE with fibrinogen and OK-432 markedly increased the CD68(+)CD163(-) infiltrating macrophages around the peri-portal area in the liver. This novel technique could be applied as immune-enhanced chemo-embolization of liver tumors. Copyright © 2016 Elsevier Inc. All rights reserved.
Inertial particle dynamics in large artery flows - Implications for modeling arterial embolisms.
Mukherjee, Debanjan; Shadden, Shawn C
2017-02-08
The complexity of inertial particle dynamics through swirling chaotic flow structures characteristic of pulsatile large-artery hemodynamics renders significant challenges in predictive understanding of transport of such particles. This is specifically crucial for arterial embolisms, where knowledge of embolus transport to major vascular beds helps in disease diagnosis and surgical planning. Using a computational framework built upon image-based CFD and discrete particle dynamics modeling, a multi-parameter sampling-based study was conducted on embolic particle dynamics and transport. The results highlighted the strong influence of material properties, embolus size, release instance, and embolus source on embolus distribution to the cerebral, renal and mesenteric, and ilio-femoral vasculature beds. The study also isolated the importance of shear-gradient lift, and elastohydrodynamic contact, in affecting embolic particle transport. Near-wall particle re-suspension due to lift alters aortogenic embolic particle dynamics significantly as compared to cardiogenic. The observations collectively indicated the complex interplay of particle inertia, fluid-particle density ratio, and wall collisions, with chaotic flow structures, which render the overall motion of the particles to be non-trivially dispersive in nature. Copyright © 2017 Elsevier Ltd. All rights reserved.
Percutaneous transfacial direct embolization of an intraosseous dural arteriovenous fistula.
Nerva, John D; Hallam, Danial K; Ghodke, Basavaraj V
2014-03-01
An intraosseous dural arteriovenous fistula (DAVF) is a rare cerebrovascular disease. The fistulous connection occurs within intraosseous diploic or transosseous emissary veins causing dilated intraosseous vascular pouches. To the authors' knowledge, this report describes the first percutaneous transfacial direct embolization of an intraosseous DAVF. A man in his 50s with blue rubber bleb nevus syndrome presented with headaches, imbalance, decreased visual acuity bilaterally, and left eye proptosis and chemosis. Imaging demonstrated an extensive intraosseous DAVF with dilated intraosseous vascular pouches throughout his cranial base and intraorbital venous congestion. He underwent staged endovascular treatment with the goal to improve his ocular symptoms. Transarterial and transvenous approaches failed to provide adequate access to the intraosseous vascular pouches. A direct, percutaneous transfacial approach was used to access the pouches for embolization with coils and liquid embolic material. Postoperative angiography demonstrated successful embolization of the pouch within the left pterygoid wing, reduced opacification of the intraosseous fistula, and elimination of intraorbital venous congestion. At 9-month follow-up, the patient's headaches had resolved, and his ocular symptomatology had improved. Endovascular access to an intraosseous DAVF is limited by the size and location of the intraosseous vascular pouches. In this case, a direct transfacial approach under image guidance facilitated access and embolization, which led to an improvement in the patient's symptoms. This technique is a novel approach for DAVF management.
Schregel, Katharina; Karch, André; Weber-Krueger, Mark; Stahrenberg, Raoul; Gröschel, Klaus; Knauth, Michael; Psychogios, Marios-Nikos; Wachter, Rolf; Liman, Jan
2017-01-01
Background. Atrial fibrillation (AF) is an important cause of embolic stroke of undetermined source (ESUS). Imaging-patterns like multiple infarcts, simultaneous involvement of different circulations, infarcts of different ages, and isolated cortical infarcts are likely to indicate cardioembolic stroke. The aim of our study was to evaluate the association between embolic stroke patterns, ESUS, and the new diagnosis of AF. Methods. Stroke etiology and imaging characteristics from patients included in the Find-AF study were obtained. Embolic stroke patterns in CT- or MR-imaging were correlated with the diagnosis of ESUS as well as the short- (on baseline ECG and during 7-day Holter) and long-term (12-month follow-up) diagnosis of AF. Results. From 281 patients included in the Find-AF study, 127 (45.2%) patients with ischemic lesions detected in CT or MRI were included. 26 (20.5%) of these patients had ESUS. At least one embolic stroke pattern was detected in 67 (52.7%) patients. Embolic stroke patterns were not associated with ESUS (OR 1.57, 0.65–3.79, p = 0.317), the short-term (OR 0.64, 0.26–1.58, p = 0.327) or long-term diagnosis of AF (OR 0.72, 0.31–1.68, p = 0.448). Conclusions. This secondary data analysis of the Find-AF study could not provide evidence for an association between embolic stroke patterns, ESUS, and the new diagnosis of AF. PMID:28536667
Maier, Ilko L; Schregel, Katharina; Karch, André; Weber-Krueger, Mark; Mikolajczyk, Rafael T; Stahrenberg, Raoul; Gröschel, Klaus; Bähr, Mathias; Knauth, Michael; Psychogios, Marios-Nikos; Wachter, Rolf; Liman, Jan
2017-01-01
Background . Atrial fibrillation (AF) is an important cause of embolic stroke of undetermined source (ESUS). Imaging-patterns like multiple infarcts, simultaneous involvement of different circulations, infarcts of different ages, and isolated cortical infarcts are likely to indicate cardioembolic stroke. The aim of our study was to evaluate the association between embolic stroke patterns, ESUS, and the new diagnosis of AF. Methods . Stroke etiology and imaging characteristics from patients included in the Find-AF study were obtained. Embolic stroke patterns in CT- or MR-imaging were correlated with the diagnosis of ESUS as well as the short- (on baseline ECG and during 7-day Holter) and long-term (12-month follow-up) diagnosis of AF. Results . From 281 patients included in the Find-AF study, 127 (45.2%) patients with ischemic lesions detected in CT or MRI were included. 26 (20.5%) of these patients had ESUS. At least one embolic stroke pattern was detected in 67 (52.7%) patients. Embolic stroke patterns were not associated with ESUS (OR 1.57, 0.65-3.79, p = 0.317), the short-term (OR 0.64, 0.26-1.58, p = 0.327) or long-term diagnosis of AF (OR 0.72, 0.31-1.68, p = 0.448). Conclusions . This secondary data analysis of the Find-AF study could not provide evidence for an association between embolic stroke patterns, ESUS, and the new diagnosis of AF.
Martin-StPaul, N K; Longepierre, D; Huc, R; Delzon, S; Burlett, R; Joffre, R; Rambal, S; Cochard, H
2014-08-01
Three methods are in widespread use to build vulnerability curves (VCs) to cavitation. The bench drying (BD) method is considered as a reference because embolism and xylem pressure are measured on large branches dehydrating in the air, in conditions similar to what happens in nature. Two other methods of embolism induction have been increasingly used. While the Cavitron (CA) uses centrifugal force to induce embolism, in the air injection (AI) method embolism is induced by forcing pressurized air to enter a stem segment. Recent studies have suggested that the AI and CA methods are inappropriate in long-vesselled species because they produce a very high-threshold xylem pressure for embolism (e.g., P50) compared with what is expected from (i) their ecophysiology in the field (native embolism, water potential and stomatal response to xylem pressure) and (ii) the P50 obtained with the BD method. However, other authors have argued that the CA and AI methods may be valid because they produce VCs similar to the BD method. In order to clarify this issue, we assessed VCs with the three above-mentioned methods on the long-vesselled Quercus ilex L. We showed that the BD VC yielded threshold xylem pressure for embolism consistent with in situ measurements of native embolism, minimal water potential and stomatal conductance. We therefore concluded that the BD method provides a reliable estimate of the VC for this species. The CA method produced a very high P50 (i.e., less negative) compared with the BD method, which is consistent with an artifact related to the vessel length. The VCs obtained with the AI method were highly variable, producing P50 ranging from -2 to -8.2 MPa. This wide variability was more related to differences in base diameter among samples than to differences in the length of samples. We concluded that this method is probably subject to an artifact linked to the distribution of vessel lengths within the sample. Overall, our results indicate that the CA and the AI should be used with extreme caution on long-vesselled species. Our results also highlight that several criteria may be helpful to assess the validity of a VC. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Pulmonary Thromboembolism: Evaluation By Intravenous Angiography
NASA Astrophysics Data System (ADS)
Pond, Gerald D.; Cook, Glenn C.; Woolfenden, James M.; Dodge, Russell R.
1981-11-01
Using perfusion lung scans as a guide, digital video subtraction angiography of the pulmonary arteries was performed in human subjects suspected of having pulmonary embolism. Dogs were employed as a pulmonary embolism model and both routine pulmonary angiography and intravenous pulmonary angiograms were obtained for comparison purposes. We have shown by our preliminary results that the technique is extremely promising as a safe and accurate alternative to routine pulmonary angiography in selected patients.
Endovascular Treatment of AICA Flow Dependent Aneurysms
Mahmoud, M.; El Serwi, A.; Alaa Habib, M.; Abou Gamrah, S.
2012-01-01
Summary Peripheral anterior inferior cerebellar artery (AICA) aneurysms are rare, accounting for less than 1% of all cerebral aneurysms. To our knowledge 34 flow-related cases including the present study have been reported in the literature. Three patients harbouring four flow dependent aneurysms were referred to our institution. Two patients presented with subarachnoid hemorrhage, one presented with cerebellar manifestations. They were all treated by endovascular embolization of the aneurysm as well as the parent artery using liquid embolic material. Two cases were embolized using NBCA, Onyx was used in the third case. No bleeding or rebleeding were encountered during the follow-up period which ranged from five to nine months. One patient developed facial palsy, cerebellar symptoms and sensorineural hearing loss. The remaining two cases did not develop any post treatment neurological complications. Endovascular management of flow-dependent AICA aneurysms by parent artery occlusion is feasible and efficient in terms of rebleeding prevention. Post embolization neurological complications are unpredictable. This depends upon the adequacy of collaterals from other cerebellar arteries. PMID:23217640
DOE Office of Scientific and Technical Information (OSTI.GOV)
Scheurig-Muenkler, C., E-mail: christian.scheurig@charite.de; Poellinger, A., E-mail: alexander.poellinger@charite.de; Wagner, M., E-mail: moritz.wagner@charite.de
Purpose: To evaluate the safety and outcome of ovarian artery embolization (OAE) in patients with collateral supply to symptomatic uterine leiomyomata. Materials and Methods: Thirteen patients with relevant leiomyoma perfusion by way of enlarged ovarian arteries underwent additional OAE during the same (N = 10) or a second procedure (N = 3). Uterine artery embolization (UAE) was performed bilaterally in 10 and unilaterally in 2 patients with a single artery. One patient had no typical uterine arteries but bilaterally enlarged ovarian arteries, prompting bilateral OAE. OAE was accomplished with coil embolization in one and particle embolization in 12 patients. Symptomsmore » before therapy and clinical outcome were assessed using a standardized questionnaire. Contrast-enhanced magnetic resonance (MR) imaging after embolization was available in 11 of 13 patients and was used to determine the percentage of fibroid infarction. Results: UAE and OAE were technically successful in all patients. One patient experienced prolonged irritation at the puncture site. Median clinical follow-up time was 16 months (range 4-37). Ten of 13 patients showed improvement or complete resolution of clinical symptoms. One patient reported only slight improvement of her symptoms. These women presented with regular menses. Two patients (15%), 47 and 48 years, both with unilateral OAE, reported permanent amenorrhea directly after embolization. Their symptoms completely resolved. Seven patients showed complete and 4 showed >90% fibroid infarction after embolization therapy. Conclusions: OAE is technically safe and effective in patients with ovarian artery collateral supply to symptomatic uterine leiomyomata. The risk of permanent amenorrhea observed in this study is similar to the reported incidence after UAE.« less
Endovascular Treatment of Dural Arteriovenous Fistulas: Single Center Experience
Oh, Jae-Sang; Oh, Hyuk-Jin; Shim, Jai-Joon; Bae, Hack-Gun; Lee, Kyeong-Seok
2016-01-01
Objective Treatment of intracranial dural arteriovenous fistulas (dAVFs) remains a challenge. However, after introduction of Onyx, transarterial approach is the preferred treatment option in many centers. We report our experience of dAVFs embolization with special emphasis on transarterial approach. Methods Seventeen embolization procedures were performed in 13 patients with dAVFs between Jan 2009 and Oct 2014. Clinical symptoms, location and type of fistulas, embolization methods, complications, radiological and clinical outcomes were evaluated using charts and PACS images. Results All 13 patients had symptomatic lesions. The locations of fistulas were transverse-sigmoid sinus in 6, middle fossa dura in 4, cavernous sinus in 2, and superior sagittal sinus in 1 patient. Cognard types were as follows : I in 4, IIa in 2, IIa+IIb in 5, and IV in 2. Embolization procedures were performed ≥2 times in 3 patients. Nine patients were treated with transarterial Onyx embolization alone. One of these required direct surgical puncture of middle meningeal artery. Complete obliteration of fistulas was achieved in 11/13 (85%) patients. There were no complications except for 1 case of Onyx migration in cavernous dAVF. Modified Rankin scale score at post-operative 3 months were 0 in 11, and 3 in 2 patients. Conclusion Transarterial Onyx embolization can be a first line therapeutic option in patients with dAVFs. However, transvenous approach should be tried first in cavernous sinus dAVF because of the risk of intracranial migration of liquid embolic materials. Furthermore, combined surgical endovascular approach can be considered as a useful option in inaccessible route. PMID:26885282
Olthof, D. C.; Lammers, A. J. J.; van Leeuwen, E. M. M.; Hoekstra, J. B. L.; ten Berge, I. J. M.
2014-01-01
Splenic artery embolization (SAE) is increasingly being used as a nonoperative management strategy for patients with blunt splenic injury following trauma. The aim of this study was to assess the splenic function of patients who were embolized. A clinical study was performed, with splenic function assessed by examining the antibody response to polysaccharide antigens (pneumococcal 23-valent polysaccharide vaccine), B-cell subsets, and the presence of Howell-Jolly bodies (HJB). The data were compared to those obtained from splenectomized patients and healthy controls (HC) who had been included in a previously conducted study. A total of 30 patients were studied: 5 who had proximal SAE, 7 who had distal SAE, 8 who had a splenectomy, and 10 HC. The median vaccine-specific antibody response of the SAE patients (fold increase, 3.97) did not differ significantly from that of the HC (5.29; P = 0.90); however, the median response of the splenectomized patients (2.30) did differ (P = 0.003). In 2 of the proximally embolized patients and none of the distally embolized patients, the ratio of the IgG antibody level postvaccination compared to that prevaccination was <2. There were no significant differences in the absolute numbers of lymphocytes or B-cell subsets between the SAE patients and the HC. HJB were not observed in the SAE patients. The splenic immune function of embolized patients was preserved, and therefore routine vaccination appears not to be indicated. Although the median antibody responses did not differ between the patients who underwent proximal SAE and those who underwent distal SAE, 2 of the 5 proximally embolized patients had insufficient responses to vaccination, whereas none of the distally embolized patients exhibited an insufficient response. Further research should be done to confirm this finding. PMID:25185578
DOE Office of Scientific and Technical Information (OSTI.GOV)
Popov, Milen; Sotiriadis, Charalampos; Gay, Frederique
PurposeTo report our experience using a multilevel patient management algorithm to direct transarterial embolization (TAE) in managing spontaneous intramuscular hematoma (SIMH).Materials and MethodsFrom May 2006 to January 2014, twenty-seven patients with SIMH had been referred for TAE to our Radiology department. Clinical status and coagulation characteristics of the patients are analyzed. An algorithm integrating CT findings is suggested to manage SIMH. Patients were classified into three groups: Type I, SIMH with no active bleeding (AB); Type II, SIMH with AB and no muscular fascia rupture (MFR); and Type III, SIMH with MFR and AB. Type II is furthermore subcategorized asmore » IIa, IIb and IIc. Types IIb, IIc and III were considered for TAE. The method of embolization as well as the material been used are described. Continuous variables are presented as mean ± SD. Categorical variables are reported as percentages. Technical success, clinical success, complications and 30-day mortality (d30 M) were analyzed.ResultsTwo patients (7.5%) had Type IIb, four (15%) Type IIc and 21 (77.5%) presented Type III. The detailed CT and CTA findings, embolization procedure and materials used are described. Technical success was 96% with a complication rate of 4%. Clinical success was 88%. The bleeding-related thirty-day mortality was 15% (all with Type III).ConclusionTAE is a safe and efficient technique to control bleeding that should be considered in selected SIMH as soon as possible. The proposed algorithm integrating CT features provides a comprehensive chart to select patients for TAE.Level of Evidence4.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hiraki, Takao; Pavcnik, Dusan, E-mail: pavcnikd@ohsu.edu; Uchida, Barry T.
2005-05-15
Objective. To explore the feasibility and efficacy of residual aneurysmal sac (RAS) embolization with the expandable hydrogel embolic device (EHED) in prevention of endoleaks in a surgically created and endoluminally treated abdominal aortic aneurysm (AAA). Methods. In eight dogs, an AAA was created by means of side-to-side anastomosis between the infrarenal abdominal aorta and inferior vena cava (IVC) with ligation of the IVC above and below the anastomotic end, followed by deployment of an endograft with holes. The RAS was then embolized with the EHED. One animal was killed immediately after RAS embolization and one animal died 12 hr aftermore » the procedure. Follow-up aortograms were obtained in six animals after 1 day (1 animal), 2 weeks and 6 months (1 animal), and 8 weeks (4 animals). Results. Four animals had no endoleaks on the follow-up aortograms. The remaining two animals with incomplete RAS embolization had moderate type III endoleaks. Type I or II endoleaks were not seen in any animals. Complications included RAS wall penetration by the devices with platinum wires in two animals (nos. 1 and 2), device migration into an aortic circulation through the endograft holes in two animals (nos. 2 and 3) or through distal interstices between the aortic wall and endograft in one animal (no. 8), aortic occlusion in three animals (nos. 3, 7, and 8), and RAS rupture in one animal (no. 7). Histologic examination showed expanded hydrogels occupying the RAS with associated mature or immature organized thrombus, fibrinous thrombus, or degenerate blood cells. Conclusion. RAS embolization was feasible with the EHED, although additional modifications to the device are required to avoid complications. Angiographic and histologic results suggested that RAS embolization with the EHED may help in the prevention of endoleaks.« less
Distal protection in cardiovascular medicine: current status.
Ali, Onn Akbar; Bhindi, Ravinay; McMahon, Aisling C; Brieger, David; Kritharides, Leonard; Lowe, Harry C
2006-08-01
Iatrogenic and spontaneous downstream microembolization of atheromatous material is increasingly recognized as a source of cardiovascular morbidity and mortality. Devising ways of reducing this distal embolization using a variety of mechanical means--distal protection--is currently under intense and diverse investigation. This review therefore summarizes the present status of distal protection. It examines the problem of distal embolization, describes the available distal protection devices, reviews those areas of cardiovascular medicine where distal protection devices are being investigated, and discusses potential future developments.
Eivazi, B; Werner, J A
2014-01-01
Venous malformations are the prototype low-flow malformations in the head and neck region. Arteriovenous malformations (AVM) represent the main high-flow malformations. In recent years it has been possible to significantly optimize the therapeutic options for venous malformations. In addition to conventional surgery, laser treatment and sclerotherapy have become established techniques and the importance of embolization with new alcohol-based materials is increasing. AVM are progressive and destructive diseases. Therapy of choice is usually a combined treatment comprising embolization and surgical removal of the arteriovenous nidus. This curative approach is usually possible if diagnosis is made at an early stage. Incomplete embolization or sole ligation of the arterial supply causes progression. There is a clear need for improved therapeutic methods and pharmacotherapeutic approaches.
Mason, K P; Neufeld, E J; Karian, V E; Zurakowski, D; Koka, B V; Burrows, P E
2001-12-01
The purpose of our study was to examine the coagulation status in patients with vascular anomalies who had undergone sclerotherapy or embolization. Ours was a prospective pilot study of 29 patients who had undergone sclerotherapy or embolization of large vascular anomalies. Fibrinogen, platelet, and d-dimer levels and prothrombin time were obtained before, immediately after, and on the day after the procedure. Five patients with venous malformations had positive d-dimer levels before the procedure. A subgroup analysis revealed a relationship between the type of agent used and the change in coagulation status. Specifically, a positive relationship was found between the use of dehydrated alcohol or sodium tetradecyl sulfate and a disruption in coagulation profiles as evidenced by a decrease in platelets and fibrinogen, an increase in prothrombin time, and a conversion from negative to positive d-dimers. In contrast, sclerotherapy or embolization with cyanoacrylic, polyvinyl alcohol foam particles, or platinum microcoils was not associated with coagulation disturbances. The coagulation disturbances that occur in response to dehydrated alcohol or sodium tetradecyl sulfate sclerotherapy or embolization could compromise the patient's clotting ability. Patients who receive dehydrated alcohol or sodium tetradecyl sulfate during a preoperative sclerotherapy or embolization may experience coagulation disturbances that could increase the risk of bleeding, thrombosis, or hematoma. This patient population may benefit from the use of glue, foam, or coils as a substitute for dehydrated alcohol or sodium tetradecyl sulfate.
Isamat, Fabian; Salleras, V.; Miranda, A. M.
1970-01-01
This report deals with a patient of 86 who developed a carotid-cavernous fistula. Artificial embolization alone was considered the safest treatment for this patient and proved to be adequate. Post-operative preservation of the patency of the internal carotid artery was demonstrated by angiography. We believe this method is particularly appropriate for carotid-cavernous fistulas if it is demonstrated by angiography that the major blood flow of the carotid artery pours into the fistula. A soft-iron clip attached to the muscle can be used for external and forceful guidance of the embolus into the fistula with the help of an electromagnet, hence the patency of the internal carotid artery can be preserved. The embolus should be introduced through the external carotid artery. This is the only case known to us in which patency of the internal carotid artery was post-operatively maintained. We have reviewed 545 reported cases of surgically treated carotid-cavernous fistulas and analysed the results from simple cervical carotid ligation to the more sophisticated methods of artificial embolizations. The results obtained by artificial embolization have been consistently good, while the other techniques have failed in large percentages. Artificial embolization should be used as the primary treatment for carotid-cavernous fistula, since ligation of the internal carotid artery precludes its embolization at a later date. Images PMID:5478949
Absolute Ethanol Embolization of Arteriovenous Malformations in the Periorbital Region
DOE Office of Scientific and Technical Information (OSTI.GOV)
Su, Li-xin, E-mail: sulixin1975@126.com; Jia, Ren-Bing, E-mail: jrb19760517@hotmail.com; Wang, De-Ming, E-mail: wdmdeming@hotmail.com
2015-06-15
ObjectiveArteriovenous malformations (AVMs) involving the periorbital region are technically challenging clinical entities to manage. The purpose of the present study was to present our initial experience of ethanol embolization in a series of 16 patients with auricular AVMs and assess the outcomes of this treatment.MethodsTranscatheter arterial embolization and/or direct percutaneous puncture embolization were performed in the 16 patients. Pure or diluted ethanol was manually injected. The follow-up evaluations included physical examination and angiography at 1- to 6-month intervals.ResultsDuring the 28 ethanol embolization sessions, the amount of ethanol used ranged from 2 to 65 mL. The obliteration of ulceration, hemorrhage, pain, infection,more » pulsation, and bruit in most of the patients was obtained. The reduction of redness, swelling, and warmth was achieved in all the 16 patients, with down-staging of the Schobinger status for each patient. AVMs were devascularized 100 % in 3 patients, 76–99 % in 7 patients, and 50–75 % in 6 patients, according to the angiographic findings. The most common complications were necrosis and reversible blister. No permanent visual abnormality was found in any of the cases.ConclusionEthanol embolization is efficacious and safe in the treatment of AVMs in the periorbital region and has the potential to be accepted as the primary mode of therapy in the management of these lesions.« less
Splenic artery embolization with Ankaferd blood stopper in a sheep model
Koç, Osman; Acar, Kadir; Özbek, Orhan; Güler, İbrahim; Sarıtaş, Kadir; Erdem, Tuba Bera; Solak, Yalçın; Toy, Hatice; Küçükapan, Ahmet; Özbek, Seda; Gaipov, Abduzhappar; Haznedaroğlu, İbrahim C.
2016-01-01
PURPOSE Splenic artery embolization is a minimally invasive therapeutic procedure utilized in a number of disorders. Ankaferd blood stopper (ABS) is a novel hemostatic agent with a new mechanism of action independent of clotting factors. We aimed to investigate the safety and efficiency of ABS for splenic artery embolization in a sheep model. METHODS Seven adult female sheep were included in the study. Selective celiac angiography was performed using a 5F diagnostic catheter and then a 2.7F hydrophilic coating microcatheter was advanced coaxially to the distal part of the main splenic artery. Under fluoroscopic guidance, 6 mL mixture composed of half-and-half ABS and contrast agent was slowly injected. Fluoroscopy was used to observe the deceleration and stagnation of the flow. Control celiac angiograms were obtained immediately after the embolization. After the procedure, the animals were observed for one day and then sacrificed with intravenous sodium thiopental. RESULTS Technical success rate was 100%. None of the animals died or experienced a major systemic adverse event during the procedure. All of the spleens appeared dark on macroscopic examination due to excessive thrombosis. Microscopically, the majority of the splenic sinusoids (90%–95%) were necrotic. CONCLUSION In our study, splenic artery embolization by ABS was found to be safe and effective in the shortterm. Further studies are needed to better understand the embolizing potential of this novel hemostatic agent. PMID:27306661
[3-D angiography in diagnosis and treatment of intracranial aneurysm].
Wang, D; Ling, F; Liu, S
2001-09-01
To summarize the results of initial application of three-dimensional angiography (3D-Angio) in diagnosis and treatment of intracranial aneurysms. From August 1999 to January 2001, standard digital subtraction angiography (two-dimensional angiography, 2D-Angio) and 3D-Angio(obtained by reconstruction of rotational angiography) were performed in 65 patients with confirmed or suspected aneurysms. Sixty-six aneurysms were found in 60 patients and nothing was found in 5. Of 66 the aneurysms (60 cases), 46 (43 cases) were treated by intrasaccule embolizotion with coils, 3 (3 cases) by occluding the parent artery with detachable balloon, 10 (10 cases) by surgery, and 1 (1 case) by combination of extracranial-intracranial bypass and balloon occlusion of parent artery. Six (3 cases) were not treated. Two aneurysms that could not be detected by 2D-Angio were diagnosed by 3D-Angio. Three aneurysms that were difficult or dangerous to embolize by 2D-Angio were embolized successfully with the help of 3D-Angio. Three aneurysms seemed to be embolized on 2D-Angio were proved impossible to be embolized on 3D-Angio. Of the 46 aneurysms embolized intrasaccularly, 38(82.6%) were completely embolized on 2D-Angio. In the 38, 8 had residual aneurysm on 3D-Angio. More accurate diagnosis and secure treatment of intracranial aneurysm can be reached by 3D-Angio.
Xylem resistance to embolism: presenting a simple diagnostic test for the open vessel artefact.
Torres-Ruiz, José M; Cochard, Hervé; Choat, Brendan; Jansen, Steven; López, Rosana; Tomášková, Ivana; Padilla-Díaz, Carmen M; Badel, Eric; Burlett, Regis; King, Andrew; Lenoir, Nicolas; Martin-StPaul, Nicolas K; Delzon, Sylvain
2017-07-01
Xylem vulnerability to embolism represents an essential trait for the evaluation of the impact of hydraulics in plant function and ecology. The standard centrifuge technique is widely used for the construction of vulnerability curves, although its accuracy when applied to species with long vessels remains under debate. We developed a simple diagnostic test to determine whether the open-vessel artefact influences centrifuge estimates of embolism resistance. Xylem samples from three species with differing vessel lengths were exposed to less negative xylem pressures via centrifugation than the minimum pressure the sample had previously experienced. Additional calibration was obtained from non-invasive measurement of embolism on intact olive plants by X-ray microtomography. Results showed artefactual decreases in hydraulic conductance (k) for samples with open vessels when exposed to a less negative xylem pressure than the minimum pressure they had previously experienced. X-Ray microtomography indicated that most of the embolism formation in olive occurs at xylem pressures below -4.0 MPa, reaching 50% loss of hydraulic conductivity at -5.3 MPa. The artefactual reductions in k induced by centrifugation underestimate embolism resistance data of species with long vessels. A simple test is suggested to avoid this open vessel artefact and to ensure the reliability of this technique in future studies. © 2017 The Authors. New Phytologist © 2017 New Phytologist Trust.
Kucher, Nils; Walpoth, Nazan; Wustmann, Kerstin; Noveanu, Markus; Gertsch, Marc
2003-06-01
To test the hypothesis that Qr in V(1)is a predictor of pulmonary embolism, right ventricular strain, and adverse clinical outcome. ECG's from 151 patients with suspected pulmonary embolism were blindly interpreted by two observers. Echocardiography, troponin I, and pro-brain natriuretic peptide levels were obtained in 75 patients with pulmonary embolism. Qr in V(1)(14 vs 0 in controls; p<0.0001) and ST elevation in V(1)> or =1 mV (15 vs 1 in controls; p=0.0002) were more frequently present in patients with pulmonary embolism. Sensitivity and specificity of Qr in V(1)and T wave inversion in V(2)for predicting right ventricular dysfunction were 31/97% and 45/94%, respectively. Three of five patients who died in-hospital and 11 of 20 patients with a complicated course, presented with Qr in V(1). After adjustment for right ventricular strain including ECG, echocardiography, pro-brain natriuretic peptide and troponin I levels, Qr in V(1)(OR 8.7, 95%CI 1.4-56.7; p=0.02) remained an independent predictor of adverse outcome. Among the ECG signs seen in patients with acute pulmonary embolism, Qr in V(1)is closely related to the presence of right ventricular dysfunction, and is an independent predictor of adverse clinical outcome.
Syed, Khalid A; Blankstein, Michael; Bhandari, Mohit; Nakane, Masaki; Zdero, Radovan; Schemitsch, Emil H
2014-03-01
The aim of this study was to compare the effect of supine versus lateral position on clinical signs of fat embolism during orthopedic trauma surgery. Dogs served as the current study model, which could be extended and/or serve as a basis for future in vivo studies on humans. It was hypothesized that there would be an effect of position on clinical signs of fat embolism syndrome in a dog model. 12 dogs were assigned to supine (n = 6) and lateral (n = 6) position groups. Airway pressures, heart rate, blood pressure, cardiac output, pulmonary artery pressure, pulmonary artery wedge pressure, right atrial pressure, arterial and venous blood gases, white blood count, platelet count and neutrophil count were obtained. Dogs were then subjected to pulmonary contusion in three areas of one lung. Fat embolism was generated by reaming one femur and tibia, followed by pressurization of the canal. No difference was found in any parameters measured between supine and lateral positions at any time (0.126 < P < 0.856). The position of trauma patients undergoing reamed intramedullary nailing did not alter the presentation of the features of the lung secondary to fat embolism.
Angiographic Findings and Embolotherapy in Renal Arterial Trauma
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sofocleous, Constantinos T., E-mail: constant@pol.net; Hinrichs, Clay; Hubbi, Basil
Purpose To evaluate the angiographic findings and embolotherapy in the management of traumatic renal arterial injury Methods This is a retrospective review of 22 patients with renal trauma who underwent arteriography and percutaneous embolization from December 1995 to January 2002. Medical records, imaging studies and procedural reports were reviewed to assess the type of injury, arteriographic findings and immediate embolization results. Long-term clinical outcome was obtained by communication with the trauma physicians and by clinical chart review.Results Arteriography was performed in 125 patients admitted to a State Trauma Center with suspected internal bleeding. Renal arterial injury was documented in 22more » and was the result of a motor-vehicle accident (10), auto-pedestrian accident (1), gunshot (4) or stab wounds (6) and a fall (1). Percutaneous renal arterial embolization was undertaken in 22 of 125 (18%) patients to treat extravasation (11), arterial pedicle rupture (5), abnormal arteriovenous (3) or arteriocalyceal (2) communication and pseudoaneurysm (3). One of the pseudoaneurysms and one of the arteriovenous fistulae were found in addition to extravasation. All 22 patients (16 men, 6 women) were hemodynamically stable, or controlled during arteriography and embolotherapy. Selective and/or superselective embolization of the abnormal vessels was performed using coils in 9 patients, microcoils in 9 patients and Gelfoam pledgets in 3 patients. In one patient Gelfoam pledgets mixed with polyvinyl alcohol (PVA) particles were used for embolization. Immediate angiographic evidence of hemostasis was demonstrated in all cases. Two initial technical failures were treated with repeat arteriography and embolization. There was no procedure-related death. There was no non-target embolization. One episode of renal abscess after embolization was treated by nephrectomy and 3 patients underwent elective post-embolization nephrectomy to prevent infection. Follow-up ranged from 1 month to 7 years (mean 31 months). No procedure-related or delayed onset of renal insufficiency occurred.Conclusion In hemodynamically stable and controlled patients selective and superselective embolization is a safe and effective method for the management of renal vascular injury.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vidal, V., E-mail: vincent.vidal@ap-hm.fr; Sapoval, M., E-mail: marc.sapoval@gmail.com; Sielezneff, Y., E-mail: igor.sielezneff@ap-hm.fr
2015-02-15
PurposeThe ‘emborrhoid’ technique consists of the embolization of the hemorrhoidal arteries. The endovascular arterial occlusion is performed using coils placed in the terminal branches of the superior rectal arteries. The emborrhoid technique has been modeled after elective transanal Doppler-guided hemorrhoidal artery ligation which has been shown to be effective in hemorrhoidal disease. We report the first 14 cases of our experience with emborrhoid technique.Materials and MethodsFourteen patients with disabling chronic rectal bleeding were treated using the emborrhoid technique (3 women, 11 men). The stage of the hemorrhoidal disease was II (10 patients), III (3), and IV (1). This treatment wasmore » decided by a multidisciplinary team (proctologist, visceral surgeon, and radiologist). Seven patients underwent previous proctological surgery. Ten patients had coagulation disorders (anticoagulants or cirrhosis). Superior rectal arteries were embolized with pushable microcoils (0.018).ResultsTechnical success of the embolization procedure was 100 %. Clinical success at 1 month was 72 % (10/14). Of the 4 patients who experienced rebleeding, two underwent additional embolization of the posterior rectal arteries with success. No pain or ischemic complications were observed in 13 patients. One patient experienced a temporary painful and edematous, perianal reaction.ConclusionOur case studies suggest that coil embolization of the superior rectal arteries is technically feasible, safe and well tolerated. Additional studies are needed to evaluate the efficacy of this new ‘emborrhoid’ technique in the management of hemorrhoidal disease.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kolber, Marcin K.; Shukla, Pratik A.; Kumar, Abhishek
PurposeRecurrent spontaneous hemarthrosis is an infrequent but debilitating late complication of joint replacement, affecting up to 1.6% of patients with arthroplasty of the affected joint. Repeated episodes of bleeding result in an inflammatory cascade that further propagates bleeding events. Open and arthroscopic synovectomy are often performed when conservative treatments fail. Transarterial embolization is increasingly utilized as a less invasive option; however, its role is not widely established. We performed a systematic literature review to report the safety and efficacy of transarterial embolization in treating recurrent hemarthrosis in the setting of prior arthroplasty.Materials and MethodsA systematic review was conducted in accordancemore » with the Preferred Reporting Items for Systematic Review and Meta-Analysis guidelines. A structured search was performed in PubMed, Web of Science, Embase, and SCOPUS databases of patients undergoing embolization for recurrent hemarthrosis after arthroplasty. Patients immediately post-operative, those embolized at first bleeding episode, and those with hemophilia were excluded. Demographic data, clinical information, angiographic findings, treatment, and outcomes were tabulated.ResultsThe search identified 119 titles of which 24 were deemed relevant, comprising 91 patients undergoing 99 embolization procedures. Mean time from prosthesis implantation was 32.2 months. Technical success was 99%. Mean follow-up time was 24.9 months. There were 10 recurrences (10%). Two cases were complicated by joint infection requiring arthroplasty revision.ConclusionsTransarterial embolization for recurrent spontaneous hemarthrosis may be safe and effective in patients having undergone arthroplasty of the affected joint.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ozyer, Umut, E-mail: umutozyer@gmail.com
IntroductionSpontaneous hematoma refractory to conservative management is a potentially serious condition that requires prompt diagnosis and intervention. The purpose of this study was to evaluate the performance of computed tomography (CT) in the treatment planning and to report the effectiveness of transcatheter embolization with N-butyl-2-cyanoacrylate (NBCA).Materials and MethodsForty-one interventions in 38 patients within a 12-year period were evaluated. CT and angiograms were reviewed for the location of the hematoma, the presence of extravasation, and the correlation of CT and angiography findings.ResultsArterial extravasation was present on 34/39 CT scans. Angiograms confirmed the CT scans in 29 cases. Angiograms revealed extravasation inmore » four cases which CT showed venous bleeding (n = 2) or no bleeding (n = 2). Five patients with arterial and 1 patient with venous extravasation on CT images had no extravasation on angiograms. Embolization was performed to all arteries with extravasation on angiograms. Empiric embolization of the corresponding artery on the CT was performed when there was no extravasation on angiograms. Embolization procedures were performed with 15 % NBCA diluted with iodized oil. Technical success was achieved in 40/41 (97.6 %) interventions. Clinical success was achieved in 35 patients with a single, in 1 patient with 2, and in 1 patient with 3 interventions. No complications related to embolization procedure occurred. None of the patients died due to a progression of the hematoma.ConclusionNBCA is an effective and safe embolic agent to treat hematoma refractory to conservative management. Contrast-enhanced CT may provide faster and more effective intervention.Level of Evidence IIIRetrospective.« less
Osanai, Toshiya; Bain, Mark D; Toth, Gabor; Hussain, M Shazam; Hui, Ferdinand K
2015-08-01
Carotid artery sacrifice remains an important procedure for cerebral vascular disorders despite the development of new endovascular devices. Conventional carotid artery sacrifice with detachable coils alone often requires numerous coils to complete occlusion. To describe the initial human experience with balloon-augmented Onyx and coil vessel sacrifice based on our previous experience with animals. We performed a retrospective review of patients who underwent carotid artery sacrifice between 2008 and 2012 in accordance with local investigational review board approval. Two methods were used to occlude carotid arteries-namely, combined Onyx and coil embolization and traditional coil embolization. We compared the two methods for the cost of embolizate, time to occlude the vessels, and the number of coils. Eight consecutive patients (combined group n=3, traditional group n=5) were assessed. The median cost of embolic material was $6321 in the combined Onyx and coil embolization group and $29 996 in the traditional coil embolization group. The median time from first coil placement to achievement of vessel occlusion was 52 min in the Onyx group and 113 min in the coil embolization group. The median number of coils used was 4 in the Onyx group and 35 in the coil embolization group (p<0.05). No symptomatic complications or recurrences were seen in the combined group. Balloon-augmented Onyx endovascular ligation may reduce costs and fluoroscopy times during vessel sacrifice. Further studies in a larger number of patients are needed to confirm these findings. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Ye, Jian; Webb, John G
2014-12-01
We report our first-in-human clinical experience in the use of the new version of the EMBOL-X intra-aortic filter (Edwards Lifesciences Corporation, Irvine, Calif) to capture embolic material during transaortic transcatheter aortic valve implantation and cardiac surgery. Five patients were enrolled into the first-in-human clinical assessment of the new version of the EMBOL-X intra-aortic filter. Three patients underwent coronary artery bypass grafting, and 2 patients underwent transaortic transcatheter aortic valve implantation. During coronary artery bypass grafting, the filter was deployed before clamping of the aorta and removal of the aortic clamp. In contrast, the filter was deployed before aortic puncture for transaortic transcatheter aortic valve implantation and kept in the aorta throughout the entire procedure. The filter introducer sheath and filter were easily placed and removed without difficulty. There were no complications related to the use of the filter. Postoperative examination of the retrieved filters revealed the presence of multiple microemboli in the filters from all 5 cases. Histologic study revealed various kinds of tissue and thrombus. This first-in-human clinical experience has demonstrated the safety and feasibility of using the new version of the EMBOL-X intra-aortic filter during either cardiac surgery or transaortic transcatheter aortic valve implantation. We believe that the combination of the transaortic approach without aortic arch manipulation and the use of the EMBOL-X filter with a high capture rate is a promising strategy to reduce the incidence of embolic complications during transcatheter aortic valve implantation. Copyright © 2014 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.
Tercero, C.; Ikeda, S.; Ooe, K.; Fukuda, T.; Arai, F.; Negoro, M.; Takahashi, I.; Kwon, G.
2012-01-01
Summary In the domain of endovascular neurosurgery, the measurement of tissue integrity is needed for simulator-based training and for the development of new intravascular instruments and treatment techniques. In vitro evaluation of tissue manipulation can be achieved using photoelastic stress analysis and vasculature modeling with photoelastic materials. In this research we constructed two types of vasculature models of saccular aneurysms for differentiation of embolization techniques according to the respect for tissue integrity measurements based on the stress within the blood vessel model wall. In an aneurysm model with 5 mm dome diameter, embolization using MicroPlex 10 (Complex 1D, with 4 mm diameter loops), a maximum area of 3.97 mm2 with stress above 1 kPa was measured. This area increased to 5.50 mm2 when the dome was touched deliberately with the release mechanism of the coil, and to 4.87 mm2 for an embolization using Micrusphere, (Spherical 18 Platinum Coil). In a similar way trans-cell stent-assisted coil embolization was also compared to human blood pressure simulation using a model of a wide-necked saccular aneurysm with 7 mm diameter. The area with stress above 1kPa was below 1 mm2 for the pressure simulation and maximized at 3.79 mm2 during the trans-cell insertion of the micro-catheter and at 8.92 mm2 during the embolization. The presented results show that this measurement system is useful for identifying techniques compromising tissue integrity, comparing and studying coils and embolization techniques for a specific vasculature morphology and comparing their natural stress variations such as that produced by blood pressure. PMID:23217635
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chabrot, Pascal, E-mail: pchabrot@chu-clermontferrand.fr; Cardot, Jean-Michel; Guibert, Pierre
Purpose: To evaluate cisplatin (CDDP) pharmacokinetics after its intravenous (IV) or intrahepatic arterial administration (IHA) in healthy pigs with or without embolization by absorbable gelatine. Material and Methods: We analysed plasmatic and hepatic drug concentration in four groups of six mini-pigs each according to the modality of administration of CDDP (1 mg/kg): IV, IHA, IHA with partial embolization using absorbable gelatine (IHA-Pe), and IHA with complete embolization (IHA-Te). Unbounded plasmatic and hepatic platinum concentrations were measured. Concentration and pharmacokinetics parameters were compared using analysis of variance. Results: For all groups, there was a rapid and biexponential decrease in free platinummore » concentration. Plasmatic terminal half-life (T{sub 1/2}) was significantly decreased after embolization at 191, 178, 42, and 41 min after IV, IHA, IHA-Pe, and IHA-Te administration, respectively. Maximal plasmatic concentration and systemic exposure to CDDP (AUC{sub 24}) values were significantly decreased after embolization (C{sub max}p = 0.0075; AUC{sub 24}p = 0.0053). Hepatic CDDP concentration rapidly peaked and then decreased progressively. After 24 h, the residual concentration represented 45, 47, 60, and 63 % of C{sub max}, respectively, after IV, IHA, IHA-Pe, and IHA-Te. Hepatic T{sub 1/2} and AUC{sub {infinity}} values were increased after embolization, but the differences were not statistically significant. Conclusion: This preliminary study confirms the feasibility of a pig model to study systemic and hepatic CDDP pharmacokinetics. Systemic exposure is lower after embolization, which could minimize systemic toxicity. Hepatic T{sub 1/2} elimination and hepatic exposition values are increased with IHA compared with IV administration.« less
Hagiwara, Akiyoshi; Tarui, Takehiko; Murata, Atsuo; Matsuda, Takeaki; Yamaguti, Yoshihiro; Shimazaki, Shuji
2005-07-01
The purpose of this study was to determine the association between bilomas and pseudoaneurysm complications after severe hepatic injury. Angiography was performed in patients with American Association for the Surgery of Trauma grade > or = III hepatic injury on contrast-enhanced computed tomographic scanning. When contrast extravasation was observed, transarterial embolization (TAE) was performed. After TAE, technetium-99m pyridoxyl-5-methyl-tryptophan cholescintigraphy was performed to detect the coexistence of bilomas. Follow-up angiography was performed when a biloma was detected. Eighty consecutive patients underwent angiography; after angiography, five patients died. The remaining 75 patients who underwent cholescintigraphy were included in this study. All 11 patients who had bilomas had angiographic evidence of contrast extravasation. The biloma frequency was higher in patients with grades IV and V injuries than in those with grade III injury (p = 0.024). Follow-up angiography revealed pseudoaneurysms in 7 of these 11 patients. All six patients in whom only gelatin sponge pledget injection was used to embolize had pseudoaneurysms. Among them, two patients had computed tomographic evidence of massive intra-abdominal fluid collection. In contrast, only one of five patients who received the combination of gelatin sponge pledget injection and stainless steel coils to permanently embolize injured arteries had a pseudoaneurysm. In this patient, the pseudoaneurysm was found in the peripheral part of the collateral vessels. All patients with pseudoaneurysms underwent repeat TAE and were discharged from the hospital uneventfully. In patients with high-grade hepatic injury and arterial bleeding who developed biloma, use of a gelatin sponge, an absorbable embolic material, is associated with a risk of pseudoaneurysm formation. Permanent arterial embolization using stainless steel coils is indicated to decrease this risk.
In vivo assessment of chitosan/β-glycerophosphate as a new liquid embolic agent.
Wang, Y; Xu, N; Luo, Q; Li, Y; Sun, L; Wang, H; Xu, K; Wang, B; Zhen, Y
2011-03-01
We sought to assess the feasibility of using thermosensitive chitosan/β-glycerophosphate forembolotherapy. The renal arteries in nine rabbits were embolized with chitosan/β-glycero-phosphate. The animals were studied angiographically and sacrificed at one week (n = 3), four weeks (n = 3), and eight weeks (n = 3) after embolotherapy. Histology was obtained at these three time points. Delivery of chitosan/β-glycerophosphate was successful in all cases. Complete occlusion was achieved in all cases. No recanalization was observed in the follow-up angiograms. No untoward inflammatory reactions were observed in the target renal arteries and infarcted kidneys during the histological examinations. Our preliminary feasibility evaluation in rabbit renal arteries indicates that C/GP is a satisfactory embolization agent.
In Vivo Assessment of Chitosan/ β-Glycerophosphate as a New Liquid Embolic Agent
Wang, Y.; Xu, N.; Luo, Q.; Li, Y.; Sun, L.; Wang, H.; Xu, K.; Wang, B.; Zhen, Y.
2011-01-01
Summary We sought to assess the feasibility of using thermosensitive chitosan/β-glycerophosphate for embolotherapy. The renal arteries in nine rabbits were embolized with chitosan/β-glycerophosphate. The animals were studied angiographically and sacrificed at one week (n = 3), four weeks (n = 3), and eight weeks (n = 3) after embolotherapy. Histology was obtained at these three time points. Delivery of chitosan/β-glycerophosphate was successful in all cases. Complete occlusion was achieved in all cases. No recanalization was observed in the follow-up angiograms. No untoward inflammatory reactions were observed in the target renal arteries and infarcted kidneys during the histological examinations. Our preliminary feasibility evaluation in rabbit renal arteries indicates that C/GP is a satisfactory embolization agent. PMID:21561564
Sun, Guohui; Feng, Chao; Jiang, Changqing; Zhang, Tingting; Bao, Zixian; Zuo, Yajun; Kong, Ming; Cheng, Xiaojie; Liu, Ya; Chen, Xiguang
2017-12-01
This work targeted to investigate the potential of thermo-responsive hydroxybutyl chitosan (HBC) hydrogel using as an embolic material for occlusion of selective blood vessels. HBC hydrogel was prepared via an etherification reaction between chitosan (CS) and 1, 2-butene oxide. The hydroxybutyl groups were introduced into CS backbone, which endowed HBC hydrogel with properties of porous structure, favorable hydrophilia and rapid sol-gel interconvertibility. The gelation temperatures and gelation time respectively decreased from 30.7°C to 11.5°C and 79.60±3.19s to 7.70±1.42s at 37°C, with HBC solutions viscoelasticity increased from 3.0% to 7.0%. HBC hydrogel exhibited noncytotoxic to mouse embryo fibroblasts (MEFs) and excellent hemocompatibility with red blood cells (RBCs). After injection HBC solution into rat renal arteries, HBC solution transformed into hydrogel and attached onto blood vessel inner wall tightly, giving immediate blood vessels embolization. Meanwhile, RBCs could aggregate around HBC hydrogel to form moderate coagulation, which was beneficial to avoid hydrogel migration with blood flow. Above results suggested that HBC hydrogel could be applied as a promising embolic agent for hemorrage in the interventional vascular embolization field. Copyright © 2017. Published by Elsevier B.V.
Modeling and Simulation of Cardiogenic Embolic Particle Transport to the Brain
NASA Astrophysics Data System (ADS)
Mukherjee, Debanjan; Jani, Neel; Shadden, Shawn C.
2015-11-01
Emboli are aggregates of cells, proteins, or fatty material, which travel along arteries distal to the point of their origin, and can potentially block blood flow to the brain, causing stroke. This is a prominent mechanism of stroke, accounting for about a third of all cases, with the heart being a prominent source of these emboli. This work presents our investigations towards developing numerical simulation frameworks for modeling the transport of embolic particles originating from the heart along the major arteries supplying the brain. The simulations are based on combining discrete particle method with image based computational fluid dynamics. Simulations of unsteady, pulsatile hemodynamics, and embolic particle transport within patient-specific geometries, with physiological boundary conditions, are presented. The analysis is focused on elucidating the distribution of particles, transport of particles in the head across the major cerebral arteries connected at the Circle of Willis, the role of hemodynamic variables on the particle trajectories, and the effect of considering one-way vs. two-way coupling methods for the particle-fluid momentum exchange. These investigations are aimed at advancing our understanding of embolic stroke using computational fluid dynamics techniques. This research was supported by the American Heart Association grant titled ``Embolic Stroke: Anatomic and Physiologic Insights from Image-Based CFD.''
DOE Office of Scientific and Technical Information (OSTI.GOV)
Raupach, J., E-mail: janraupach@seznam.cz; Lojik, M., E-mail: miroslav.lojik@fnhk.cz; Chovanec, V., E-mail: chovanec.v@seznam.cz
2016-02-15
PurposeRetrospective evaluation of 12-year experience with endovascular management of acute mesenteric ischemia (AMI) due to embolic occlusion of the superior mesenteric artery (SMA).Materials and methodsFrom 2003 to 2014, we analysed the in-hospital mortality of 37 patients with acute mesenteric embolism who underwent primary endovascular therapy with subsequent on-demand laparotomy. Transcatheter embolus aspiration was used in all 37 patients (19 women, 18 men, median age 76 years) with embolic occlusion of the SMA. Adjunctive local thrombolysis (n = 2) and stenting (n = 2) were also utilised.ResultsWe achieved complete recanalization of the SMA stem in 91.9 %. One patient was successfully treated by surgical embolectomy due tomore » a failed endovascular approach. Subsequent exploratory laparotomy was performed in 73.0 % (n = 27), and necrotic bowel resection in 40.5 %. The total in-hospital mortality was 27.0 %.ConclusionPrimary endovascular therapy for acute embolic SMA occlusion with on-demand laparotomy is a recommended algorithm used in our centre to treat SMA occlusion. This combined approach for the treatment of AMI is associated with in-hospital mortality rate of 27.0 %.« less
Demachi, H; Matsui, O; Abo, H; Tatsu, H
2000-01-01
To verify the difference in embolic effect between oil-in-water (O-W) and water-in-oil (W-O) emulsions composed of iodized oil and an anticancer drug, epirubicin, using a simulation model based on non-Newtonian fluid mechanics. Flow curves of pure iodized oil and two types of O-W and W-O emulsions immediately and 1 hr after preparation were examined with a viscometer. Using the yield stress data obtained, we simulated the stagnation of each fluid with steady flow in a rigid tube. The W-O emulsions were observed to stagnate in the thin tube at a low pressure gradient. However, the embolic effect of the W-O emulsions decreased 1 hr after preparation. The O-W emulsions were stable and did not stagnate under the conditions in which the W-O emulsions stagnated. The simulation model showed that the embolic effect of the W-O emulsions was superior to that of the O-W emulsions.
Denoising embolic Doppler ultrasound signals using Dual Tree Complex Discrete Wavelet Transform.
Serbes, Gorkem; Aydin, Nizamettin
2010-01-01
Early and accurate detection of asymptomatic emboli is important for monitoring of preventive therapy in stroke-prone patients. One of the problems in detection of emboli is the identification of an embolic signal caused by very small emboli. The amplitude of the embolic signal may be so small that advanced processing methods are required to distinguish these signals from Doppler signals arising from red blood cells. In this study instead of conventional discrete wavelet transform, the Dual Tree Complex Discrete Wavelet Transform was used for denoising embolic signals. Performances of both approaches were compared. Unlike the conventional discrete wavelet transform discrete complex wavelet transform is a shift invariant transform with limited redundancy. Results demonstrate that the Dual Tree Complex Discrete Wavelet Transform based denoising outperforms conventional discrete wavelet denoising. Approximately 8 dB improvement is obtained by using the Dual Tree Complex Discrete Wavelet Transform compared to the improvement provided by the conventional Discrete Wavelet Transform (less than 5 dB).
Daniel, Pinto Dos Santos; Sonja, Scheibl; Gordon, Arnhold; Aline, Maehringer-Kunz; Christoph, Düber; Peter, Mildenberger; Roman, Kloeckner
2018-05-10
This paper studies the possibilities of an integrated IT-based workflow for epidemiological research in pulmonary embolism using freely available tools and structured reporting. We included a total of 521 consecutive cases which had been referred to the radiology department for computed tomography pulmonary angiography (CTPA) with suspected pulmonary embolism (PE). Free-text reports were transformed into structured reports using a freely available IHE-MRRT-compliant reporting platform. D-dimer values were retrieved from the hospitals laboratory results system. All information was stored in the platform's database and visualized using freely available tools. For further analysis, we directly accessed the platform's database with an advanced analytics tool (RapidMiner). We were able developed an integrated workflow for epidemiological statistics from reports obtained in clinical routine. The report data allowed for automated calculation of epidemiological parameters. Prevalence of pulmonary embolism was 27.6%. The mean age in patients with and without pulmonary embolism did not differ (62.8 years and 62.0 years, respectively, p=0.987). As expected, there was a significant difference in mean D-dimer values (10.13 mg/L FEU and 3.12 mg/L FEU, respectively, p<0.001). Structured reporting can make data obtained from clinical routine more accessible. Designing practical workflows is feasible using freely available tools and allows for the calculation of epidemiological statistics on a near real-time basis. Therefore, radiologists should push for the implementation of structured reporting in clinical routine. Advances in knowledge: Theoretical benefits of structured reporting have long been discussed, but practical implementation demonstrating those benefits has been lacking. Here we present a first experience providing proof that structured reporting will make data from clinical routine more accessible.
Mahmoud, M; El Serwi, A; Alaa Habib, M; Abou Gamrah, S
2012-12-01
Peripheral anterior inferior cerebellar artery (AICA) aneurysms are rare, accounting for less than 1% of all cerebral aneurysms. To our knowledge 34 flow-related cases including the present study have been reported in the literature. Three patients harbouring four flow dependent aneurysms were referred to our institution. Two patients presented with subarachnoid hemorrhage, one presented with cerebellar manifestations. They were all treated by endovascular embolization of the aneurysm as well as the parent artery using liquid embolic material. Two cases were embolized using NBCA, Onyx was used in the third case. No bleeding or rebleeding were encountered during the follow-up period which ranged from five to nine months. One patient developed facial palsy, cerebellar symptoms and sensorineural hearing loss. The remaining two cases did not develop any post treatment neurological complications. Endovascular management of flow-dependent AICA aneurysms by parent artery occlusion is feasible and efficient in terms of rebleeding prevention. Post embolization neurological complications are unpredictable. This depends upon the adequacy of collaterals from other cerebellar arteries.
Endovascular embolization of varicoceles using n-butyl cyanoacrylate (NBCA) glue
Pietura, Radosław; Toborek, Michał; Dudek, Aneta; Boćkowska, Agata; Janicka, Joanna; Piekarski, Paweł
2013-01-01
Summary Background: Varicoceles are abnormally dilated veins within the pampiniform plexus. They are caused by reflux of blood in the internal spermatic vein. The incidence of varicoceles is approximately 10–15% of the adolescent male population. The etiology of varicoceles is probably multifactorial. The diagnosis is based on Doppler US. Treatment could be endovascular or surgical. The aim of the study was to describe and evaluate a novel method of endovascular embolization of varicoceles using n-butyl cyanoacrylate (NBCA) glue. Material/Methods: 17 patients were subjected to endovascular treatment of varicoceles using NBCA. A 2.8 Fr microcatheter and a 1:1 mixture of NBCA and lipiodol were used for embolization of the spermatic vein. Results: All 17 procedures were successful. There were no complications. Discussion: Embolization of varicoceles using NBCA glue is efficient and safe for all patients. The method should be considered as a method of choice in all patients. Phlebography and Valsalva maneuver are crucial for technical success and avoidance of complications. Conclusions: Endovascular treatment of varicoceles using NBCA glue is very effective and safe. PMID:23807881
Role of transcatheter arterial embolization for massive bleeding from gastroduodenal ulcers
Loffroy, Romaric; Guiu, Boris
2009-01-01
Intractable bleeding from gastric and duodenal ulcers is associated with significant morbidity and mortality. Aggressive treatment with early endoscopic hemostasis is essential for a favourable outcome. In as many as 12%-17% of patients, endoscopy is either not available or unsuccessful. Endovascular therapy with selective catheterization of the culprit vessel and injection of embolic material has emerged as an alternative to emergent operative intervention in high-risk patients. There has not been a systematic literature review to assess the role for embolotherapy in the treatment of acute upper gastrointestinal bleeding from gastroduodenal ulcers after failed endoscopic hemostasis. Here, we present an overview of indications, techniques, and clinical outcomes after endovascular embolization of acute peptic-ulcer bleeding. Topics of particular relevance to technical and clinical success are also discussed. Our review shows that transcatheter arterial embolization is a safe alternative to surgery for massive gastroduodenal bleeding that is refractory to endoscopic treatment, can be performed with high technical and clinical success rates, and should be considered the salvage treatment of choice in patients at high surgical risk. PMID:20014452
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bent, Clare L., E-mail: clare_bent@yahoo.co.uk; Low, Deborah; Matson, Matthew B.
The purpose of this study was to assess whether portal vein embolization (PVE) using a nitinol vascular plug in combination with histoacryl glue and iodinized oil minimizes the risk of nontarget embolization while obtaining good levels of future liver remnant (FLR) hypertrophy. Between November 2005 and August 2008, 16 patients (8 females, 8 males; mean age, 63 {+-} 3.6 years), each with a small FLR, underwent right ipsilateral transhepatic PVE prior to major hepatectomy. Proximal PVE was initially performed by placement of a nitinol vascular plug, followed by distal embolization using a mixture of histoacryl glue and iodinized oil. Pre-more » and 6 weeks postprocedural FLR volumes were calculated using computed tomographic imaging. Selection for surgery required an FLR of 0.5% of the patient's body mass. Clinical course and outcome of surgical resection for all patients were recorded. At surgery, the ease of hepatectomy was subjectively assessed in comparison to previous experience following PVE with alternative embolic agents. PVE was successful in all patients. Mean procedure time was 30.4 {+-} 2.5 min. Mean absolute increase in FLR volume was 68.9% {+-} 12.0% (p = 0.00005). There was no evidence of nontarget embolization during the procedure or on subsequent imaging. Nine patients proceeded to extended hepatectomy. Six patients demonstrated disease progression. One patient did not achieve sufficient hypertrophy in relation to body mass to undergo hepatic resection. At surgery, the hepatobiliary surgeons observed less periportal inflammation compared to previous experience with alternative embolic agents, facilitating dissection at extended hepatectomy. In conclusion, ipsilateral transhepatic PVE using a single nitinol plug in combination with histoacryl glue and iodinized oil simplifies the procedure, offering short procedural times with minimal risk of nontarget embolization. Excellent levels of FLR hypertrophy are achieved enabling safe extended hepatectomy.« less
Dolci, Daniel T; Fuentes, Carolina B; Rolim, Denise; Park, Marcelo; Schettino, Guilherme P P; Azevedo, Luciano C P
2010-01-01
The time course of cardiopulmonary alterations after pulmonary embolism has not been clearly demonstrated and nor has the role of systemic inflammation on the pathogenesis of the disease. This study aimed to evaluate over 12 h the effects of pulmonary embolism caused by polystyrene microspheres on the haemodynamics, lung mechanics and gas exchange and on interleukin-6 production. Ten large white pigs (weight 35-42 kg) had arterial and pulmonary catheters inserted and pulmonary embolism was induced in five pigs by injection of polystyrene microspheres (diameter approximately 300 micromol l(-1)) until a value of pulmonary mean arterial pressure of twice the baseline was obtained. Five other animals received only saline. Haemodynamic and respiratory data and pressure-volume curves of the respiratory system were collected. A bronchoscopy was performed before and 12 h after embolism, when the animals were euthanized. The embolism group developed hypoxaemia that was not corrected with high oxygen fractions, as well as higher values of dead space, airway resistance and lower respiratory compliance levels. Acute haemodynamic alterations included pulmonary arterial hypertension with preserved systemic arterial pressure and cardiac index. These derangements persisted until the end of the experiments. The plasma interleukin-6 concentrations were similar in both groups; however, an increase in core temperature and a nonsignificant higher concentration of bronchoalveolar lavage proteins were found in the embolism group. Acute pulmonary embolism induced by polystyrene microspheres in pigs produces a 12-h lasting hypoxaemia and a high dead space associated with high airway resistance and low compliance. There were no plasma systemic markers of inflammation, but a higher central temperature and a trend towards higher bronchoalveolar lavage proteins were found.
Sheen, Jae Jon; Jiang, Yuan Yuan; Kim, Young Eun; Maeng, Jun Young; Kim, Tae-Il; Lee, Deok Hee
2018-03-23
Onyx embolization is a treatment for brain arteriovenous malformations (AVMs). However, multistage embolization usually involves the presence of radiodense Onyx cast from the previous sessions, which may influence the fluoroscopic radiation dose. We compared the fluoroscopic dose between the initial and final embolization sessions. From January 2014 to September 2016, 18 patients underwent multistage Onyx embolization (more than twice) for brain AVMs. The total fluoroscopic duration (minutes), dose-area product (DAP, Gy×cm 2 ), and cumulative air kerma (CAK, mGy) of both the frontal and lateral planes were obtained. We compared the frontal and lateral fluoroscopic dose rates (dose/time) of the final embolization session with those of the initial session. The relationship between the injected Onyx volume and radiation dose was tested. The initial and final procedures on the frontal plane showed significantly different fluoroscopic dose rates (DAP: initial 0.668 Gy×cm 2 /min, final 0.848 Gy×cm 2 /min, P=0.02; CAK: initial 12.7 mGy/min, final 23.1 mGy/min, P=0.007). Those on the lateral plane also showed a similar pattern (DAP: initial 0.365 Gy×cm 2 /min, final 0.519 Gy×cm 2 /min, P=0.03; CAK: initial 6.2 mGy/min, final 12.9 mGy/min, P=0.01). The correlation between the cumulative Onyx volume (vials) and radiation dose ratio of both planes showed an increasing trend (rho 0.4325-0.7053; P=0.0011-0.0730). Owing to the automatic exposure control function during fluoroscopy, successive Onyx embolization procedures increase the fluoroscopic radiation dose in multistage brain AVM embolization because of the presence of radiodense Onyx mass. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Olthof, D C; Lammers, A J J; van Leeuwen, E M M; Hoekstra, J B L; ten Berge, I J M; Goslings, J C
2014-11-01
Splenic artery embolization (SAE) is increasingly being used as a nonoperative management strategy for patients with blunt splenic injury following trauma. The aim of this study was to assess the splenic function of patients who were embolized. A clinical study was performed, with splenic function assessed by examining the antibody response to polysaccharide antigens (pneumococcal 23-valent polysaccharide vaccine), B-cell subsets, and the presence of Howell-Jolly bodies (HJB). The data were compared to those obtained from splenectomized patients and healthy controls (HC) who had been included in a previously conducted study. A total of 30 patients were studied: 5 who had proximal SAE, 7 who had distal SAE, 8 who had a splenectomy, and 10 HC. The median vaccine-specific antibody response of the SAE patients (fold increase, 3.97) did not differ significantly from that of the HC (5.29; P = 0.90); however, the median response of the splenectomized patients (2.30) did differ (P = 0.003). In 2 of the proximally embolized patients and none of the distally embolized patients, the ratio of the IgG antibody level postvaccination compared to that prevaccination was <2. There were no significant differences in the absolute numbers of lymphocytes or B-cell subsets between the SAE patients and the HC. HJB were not observed in the SAE patients. The splenic immune function of embolized patients was preserved, and therefore routine vaccination appears not to be indicated. Although the median antibody responses did not differ between the patients who underwent proximal SAE and those who underwent distal SAE, 2 of the 5 proximally embolized patients had insufficient responses to vaccination, whereas none of the distally embolized patients exhibited an insufficient response. Further research should be done to confirm this finding. Copyright © 2014, American Society for Microbiology. All Rights Reserved.
Wnuk, Emilia; Maciag, Rafal; Solonynko, Bohdan; Korzeniowski, Krzysztof; Lamparski, Krzysztof; Rowinski, Olgierd
2016-01-01
Introduction Type 2 endoleaks (T2E) occur in 10 to 20% of patients after endovascular abdominal aortic aneurysm repair (EVAR) and remain a significant clinical issue. Aim To evaluate the efficacy and clinical outcomes of transarterial treatment of persistent type II endoleaks after EVAR using the liquid embolic Onyx. Material and methods From February 2012 to August 2015 transarterial T2E embolization was attempted in 22 patients (21 men, median age: 73, range: 62–88 years). Indications for treatment included an increase in the diameter of the aneurysm sac above 5 mm and a persistent endoleak observed for more than 6 months. Mean time from EVAR to endoleak treatment was 43 months (range: 2–125 months). Results Primary technical success was achieved in 17 (77.3%) patients and secondary technical success in 81.8%, with 0% in-hospital mortality. The mean procedure time was 95 ±48 min, with an average fluoroscopy time of 54 ±25 min. The mean amount of Onyx used was 7.5 ±6.6 ml. Clinical success was seen in 17/21 patients with follow-up imaging (80.9%). Mean follow-up time was 17 months (range: 3–38 months). Conclusions Onyx has been shown to effectively stabilize previous aneurysm growth as a result of the T2E in the majority of our patients. Transarterial embolization of T2E can be significantly improved as compared to previously reported results by using liquid embolic polymers such as Onyx. PMID:28194246
Endovascular Management of Intractable Postpartum Hemorrhage Caused by Vaginal Laceration
DOE Office of Scientific and Technical Information (OSTI.GOV)
Koganemaru, Masamichi, E-mail: mkoganemaru@med.kurume-u.ac.jp; Nonoshita, Masaaki, E-mail: z2rs-1973@yahoo.co.jp; Iwamoto, Ryoji, E-mail: iwamoto-ryouji@kurume-u.ac.jp
PurposeWe evaluated the management of transcatheter arterial embolization for postpartum hemorrhage caused by vaginal laceration.Materials and MethodsWe reviewed seven cases of patients (mean age 30.9 years; range 27–35) with intractable hemorrhages and pelvic hematomas caused by vaginal lacerations, who underwent superselective transcatheter arterial embolization from January 2008 to July 2014. Postpartum hemorrhage was evaluated by angiographic vascular mapping to determine the vaginal artery’s architecture, technical and clinical success rates, and complications.ResultsThe vaginal artery was confirmed as the source of bleeding in all cases. The artery was found to originate from the uterine artery in three cases, the uterine and obturator arteriesmore » in two, or the internal pudendal artery in two. After vaginal artery embolization, persistent contrast extravasation from the inferior mesenteric artery as an anastomotic branch was noted in one patient. Nontarget vessels (the inferior vesical artery and nonbleeding vaginal arterial branches) were embolized in one patient. Effective control of hemostasis and no post-procedural complications were confirmed for all cases.ConclusionPostpartum hemorrhages caused by vaginal lacerations involve the vaginal artery arising from the anterior trunk of the internal iliac artery with various branching patterns. Superselective vaginal artery embolization is clinically acceptable for the successful treatment of vaginal laceration hemorrhages, with no complications. After vaginal artery embolization, it is suggested to check for the presence of other possible bleeding vessels by pelvic aortography with a catheter tip at the L3 vertebral level, and to perform a follow-up assessment.« less
Popov, Milen; Sotiriadis, Charalampos; Gay, Frederique; Jouannic, Anne-Marie; Lachenal, Yann; Hajdu, Steven D; Doenz, Francesco; Qanadli, Salah D
2017-04-01
To report our experience using a multilevel patient management algorithm to direct transarterial embolization (TAE) in managing spontaneous intramuscular hematoma (SIMH). From May 2006 to January 2014, twenty-seven patients with SIMH had been referred for TAE to our Radiology department. Clinical status and coagulation characteristics of the patients are analyzed. An algorithm integrating CT findings is suggested to manage SIMH. Patients were classified into three groups: Type I, SIMH with no active bleeding (AB); Type II, SIMH with AB and no muscular fascia rupture (MFR); and Type III, SIMH with MFR and AB. Type II is furthermore subcategorized as IIa, IIb and IIc. Types IIb, IIc and III were considered for TAE. The method of embolization as well as the material been used are described. Continuous variables are presented as mean ± SD. Categorical variables are reported as percentages. Technical success, clinical success, complications and 30-day mortality (d30 M) were analyzed. Two patients (7.5%) had Type IIb, four (15%) Type IIc and 21 (77.5%) presented Type III. The detailed CT and CTA findings, embolization procedure and materials used are described. Technical success was 96% with a complication rate of 4%. Clinical success was 88%. The bleeding-related thirty-day mortality was 15% (all with Type III). TAE is a safe and efficient technique to control bleeding that should be considered in selected SIMH as soon as possible. The proposed algorithm integrating CT features provides a comprehensive chart to select patients for TAE. 4.
Portal Vein Embolization Before Liver Resection: A Systematic Review
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lienden, K. P. van, E-mail: k.p.vanlienden@amc.uva.nl; Esschert, J. W. van den; Graaf, W. de
2013-02-15
This is a review of literature on the indications, technique, and outcome of portal vein embolization (PVE). A systematic literature search on outcome of PVE from 1990 to 2011 was performed in Medline, Cochrane, and Embase databases. Forty-four articles were selected, including 1,791 patients with a mean age of 61 {+-} 4.1 years. Overall technical success rate was 99.3 %. The mean hypertrophy rate of the FRL after PVE was 37.9 {+-} 0.1 %. In 70 patients (3.9 %), surgery was not performed because of failure of PVE (clinical success rate 96.1 %). In 51 patients (2.8 %), the hypertrophymore » response was insufficient to perform liver resection. In the other 17 cases, 12 did not technically succeed (0.7 %) and 7 caused a complication leading to unresectability (0.4 %). In 6.1 %, resection was cancelled because of local tumor progression after PVE. Major complications were seen in 2.5 %, and the mortality rate was 0.1 %. A head-to-head comparison shows a negative effect of liver cirrhosis on hypertrophy response. The use of n-butyl cyanoacrylate seems to have a greater effect on hypertrophy, but the difference with other embolization materials did not reach statistical significance. No difference in regeneration is seen in patients with cholestasis or chemotherapy. Preoperative PVE has a high technical and clinical success rate. Liver cirrhosis has a negative effect on regeneration, but cholestasis and chemotherapy do not seem to have an influence on the hypertrophy response. The use of n-butyl cyanoacrylate may result in a greater hypertrophy response compared with other embolization materials used.« less
Kim, Jae Min; Kim, Man-Deuk; Han, Kichang; Muqmiroh, Lailatul; Kim, Seung Up; Kim, Gyoung Min; Kwon, Joonho; Park, Sung Il; Won, Jong Yun; Lee, Do Yun
2017-05-01
To evaluate the effect of bariatric arterial embolization (BAE) with non-spherical polyvinyl alcohol (PVA) particles on systemic ghrelin levels, weight change, and gastric ulceration risk in a swine model. From March 2014 to February 2015, ten healthy swine were used in the study (mean weight 31.5 kg; range 24.0-41.5 kg). The animals were randomly assigned to two groups: the embolized group (n = 5) in which BAE was performed and the control group (n = 5). In the embolized group, BAE was performed by selectively infusing 150-250 or 50-150 μm PVA into the gastric arteries that supplied the fundus of the stomach. In the control group, a sham procedure was performed with saline infusion. Plasma ghrelin levels were prospectively obtained at baseline and every 2 weeks thereafter. Endoscopy was performed 3 weeks after BAE to see whether any gastric ulcer occurred. To determine the durability of the occluded arteries, repeated celiac trunk angiography was performed 8 weeks after BAE. Then, all the swine were killed and necropsies were performed. The mean post-procedure ghrelin value decreased by 370.0 pg/mL in the embolized group at week 3 (mean 536.0 ± 334.3 pg/mL) and week 5 (mean 515.0 ± 150.0 pg/mL, p < 0.05) relative to baseline (880.0 ± 559.5 pg/mL), respectively, but ghrelin levels were not significantly decreased between the embolized and control groups. There was a significant body weight change as follows: 35.1 ± 9.5 to 46.6 ± 15.7 kg and 31.8 ± 5.8 to 41.2 ± 6.6 kg at baseline and endpoint in the control and embolized groups, respectively (p < 0.05). However, the difference between groups was not significant at endpoint. In the embolized group, ulcerations were identified in three animals (60%) and the recanalization of the embolized arteries was noted on follow-up angiography in three animals (60%), respectively. BAE with PVA particles can transiently suppress ghrelin levels in embolized animals, but levels are not significantly different compared to controls. Stomach ulcerations were identified in 60% of the embolized animals.
Delayed coma in head injury: consider cerebral fat embolism.
Metting, Zwany; Rödiger, Lars A; Regtien, Joost G; van der Naalt, Joukje
2009-09-01
To describe a case of a young man with delayed coma after mild head injury, suggestive of cerebral fat embolism (CFE). To underline the value of MR imaging in the differential diagnosis of secondary deterioration in mild head injury. A 21-year-old man admitted with mild head injury after a fall with facial fractures and long bone fractures. He was admitted to the intensive care unit and was mechanically ventilated. Weaning was not possible because of desaturations and pulmonary congestion. Low platelet count and anaemia developed. On several time points during his admission cerebral imaging data were obtained. Non-contrast CT on admission was normal while follow-up MRI showed extensive white matter abnormalities. These imaging abnormalities combined with the clinical presentation suggests cerebral fat embolism (CFE) as the most likely cause of secondary deterioration in our patient. In head injured patients with long bone fractures one should consider cerebral fat embolism. When the classical clinical syndrome is not present, MR imaging is warranted for diagnosis and to exclude other causes of secondary deterioration.
Benali, Zine El Abidine; Abdedaim, Hatim; Omari, Driss
2013-01-01
Cases of embolism after using hydrogen peroxide have been described in many circumstances in the operating room. Hydrogen peroxide is not more effective than other antiseptics; its potentially serious risk should not be unrecognized. The alternative use of saline seems very reasonable. The widespread use of hydrogen peroxide by practitioners is explained mainly by its antiseptic effect associated with effervescent backlash visual and auditory, but sometimes the liquid hiding behind a black hole that absorbs the life of the patient in case of inappropriate use. Diagnosis is based on clinical variations in a conscious patient at the time of use, confirmed by echocardiology if available. We related the case of a massive embolism after hydrogen peroxide use in the cleaning of infected wound with osteosynthesis material left femoral done under spinal anesthesia in a young girl of 17 years admitted after to the ICU intubated ventilated. PMID:24839532
Maghemite based silicone composite for arterial embolization hyperthermia.
Smolkova, Ilona S; Kazantseva, Natalia E; Makoveckaya, Kira N; Smolka, Petr; Saha, Petr; Granov, Anatoly M
2015-03-01
Maghemite nanoparticle based silicone composite for application in arterial embolization hyperthermia is developed. It possesses embolization ability, high heating efficiency in alternating magnetic fields and radiopaque property. The initial components of the composite are selected so that the material stays liquid for 20min, providing the opportunity for transcatheter transportation and filling of the tumour vascular system. After this induction period the viscosity increases rapidly and soft embolus is formed which is able to occlude the tumour blood vessels. The composite is thermally stable up to 225°C, displays rubber-elastic properties and has a thermal expansion coefficient higher than that of blood. Maghemite nanoparticles uniformly distributed in the composite provide its rapid heating (tens of °Cmin(-1)) due to Neel magnetization relaxation. Required X-ray contrast of composite is achieved by addition of potassium iodide. Copyright © 2014 Elsevier B.V. All rights reserved.
Mikat, Christian; Stenzel, Elena; Erfanian, Youssef; Wetter, Axel; Schlosser, Thomas; Forsting, Michael
2017-01-01
Objectives To evaluate the image quality and radiation dose of submillisievert standard-pitch CT pulmonary angiography (CTPA) with ultra-low dose contrast media administration in comparison to standard CTPA. Materials and methods Hundred patients (56 females, 44 males, mean age 69.6±15.4 years; median BMI: 26.6, IQR: 5.9) with suspected pulmonary embolism were examined with two different protocols (n = 50 each, group A: 80 kVp, ref. mAs 115, 25 ml of contrast medium; group B: 100 kVp, ref. mAs 150, 60 ml of contrast medium) using a dual-source CT equipped with automated exposure control. Objective and subjective image qualities, radiation exposure as well as the frequency of pulmonary embolism were evaluated. Results There was no significant difference in subjective image quality scores between two groups regarding pulmonary arteries (p = 0.776), whereby the interobserver agreement was excellent (group A: k = 0.9; group B k = 1.0). Objective image analysis revealed that signal intensities (SI), signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of the pulmonary arteries were equal or significantly higher in group B. There was no significant difference in the frequency of pulmonary embolism (p = 0.65). Using the low dose and low contrast media protocol resulted in a radiation dose reduction by 71.8% (2.4 vs. 0.7 mSv; p<0.001). Conclusions This 80 kVp standard pitch CTPA protocol with 25 ml contrast agent volume can obtain sufficient image quality to exclude or diagnose pulmonary emboli while reducing radiation dose by approximately 71%. PMID:29045463
Ishikawa, Masaki; Kakizawa, Hideaki; Yamasaki, Wataru; Date, Syuji; Hieda, Masashi; Kajiwara, Kenji; Awai, Kazuo
2011-12-01
A 70-year-old male with advanced pancreatic cancer went into shock after sustaining a traumatic abdominal injury. Computed tomography (CT) showed a hematoma with extravasation around the pancreas and hemorrhagic ascites. After direct catheterization failed due to angiospasm, the ruptured splenic artery was successfully occluded by transcatheter arterial embolization (TAE) using an N-butyl cyanoacrylate (NBCA)-lipiodol mixture and the patient recovered from shock without complications. A follow-up CT obtained 20 days later showed a recurrent splenic artery pseudoaneurysm without extravasation. A repeat angiogram demonstrated recanalization of the splenic artery and pseudoaneurysm via antegrade. We embolized the recanalized pseudoaneurysm using metallic coils for isolation. Our experience indicates that adequate concentration and volume of the NBCA-lipiodol mixture should be considered depending on the vascular spasm in a patient with hypovolemic shock.
Microcoil Embolization for Acute Lower Gastrointestinal Bleeding
DOE Office of Scientific and Technical Information (OSTI.GOV)
D'Othee, Bertrand Janne, E-mail: bjanne@caregroup.harvard.edu; Surapaneni, Padmaja; Rabkin, Dmitry
2006-02-15
Purpose. To assess outcomes after microcoil embolization for active lower gastrointestinal (GI) bleeding. Methods. We retrospectively studied all consecutive patients in whom microcoil embolization was attempted to treat acute lower GI bleeding over 88 months. Baseline, procedural, and outcome parameters were recorded following current Society of Interventional Radiology guidelines. Outcomes included technical success, clinical success (rebleeding within 30 days), delayed rebleeding (>30 days), and major and minor complication rates. Follow-up consisted of clinical, endoscopic, and pathologic data. Results. Nineteen patients (13 men, 6 women; mean age {+-} 95% confidence interval = 70 {+-} 6 years) requiring blood transfusion (10 {+-}more » 3 units) had angiography-proven bleeding distal to the marginal artery. Main comorbidities were malignancy (42%), coagulopathy (28%), and renal failure (26%). Bleeding was located in the small bowel (n = 5), colon (n 13) or rectum (n = 1). Technical success was obtained in 17 patients (89%); 2 patients could not be embolized due to vessel tortuosity and stenoses. Clinical follow-up length was 145 {+-} 75 days. Clinical success was complete in 13 (68%), partial in 3 (16%), and failed in 2 patients (11%). Delayed rebleeding (3 patients, 27%) was always due to a different lesion in another bowel segment (0 late rebleeding in embolized area). Two patients experienced colonic ischemia (11%) and underwent uneventful colectomy. Two minor complications were noted. Conclusion. Microcoil embolization for active lower GI bleeding is safe and effective in most patients, with high technical and clinical success rates, no procedure-related mortality, and a low risk of bowel ischemia and late rebleeding.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Amouyal, Gregory, E-mail: gregamouyal@hotmail.com; Chague, Pierre, E-mail: pierre.chague@gmail.com; Pellerin, Olivier, E-mail: olivier.pellerin@aphp.fr
IntroductionDuring PAE, preembolization angiography of the prostatic artery can show large extra-prostatic shunts, at high risk, if embolized, of rectal or penile necrosis. We report our experience with 11 consecutive patients who underwent protective embolization of large extra-prostatic shunts before successful PAE.Materials and MethodsWe treated 11 consecutive male patients (mean age 67 years), part of a series of 55 consecutive male patients referred for PAE to treat LUTS due to BPH, between December 2013 and January 2015. The procedure involved the exclusion of an extra-prostatic shunt originating from the PA, prior to complete bilateral PAE. We compared the safety and efficacymore » of the 11 shunt exclusions followed by embolization of the PA to the other 44 basic PAE. Clinical success was defined as a decrease of 25 % or eight points of IPSS, QoL <3 or a one-point decrease, and a Qmax improvement of 25 % or 2.5 mL/s.ResultsWe had a 100 % rate of occlusion of the anastomosis. Bilateral embolization of the PA was performed in all patients with no additional time of procedure (p = 0.18), but a significant increase of dose area product (p = 0.03). Distal (PErFecTED) embolization was possible in 64 %. There was no worsening of erectile dysfunction, no rectal or penile necrosis, no immediate or late other clinical complications. Clinical success was 91 % (mean follow-up: 3.5 months), compared to 78 % for the entire PAE group.ConclusionPAE using the protection technique in case of large extra-prostatic shunts is as safe and effective as basic procedures and does not induce any additional time of procedure.« less
Zwieniecki, Maciej A; Melcher, Peter J; Ahrens, Eric T
2013-01-01
We report results of an analysis of embolism formation and subsequent refilling observed in stems of Acer rubrum L. using magnetic resonance imaging (MRI). MRI is one of the very few techniques that can provide direct non-destructive observations of the water content within opaque biological materials at a micrometer resolution. Thus, it has been used to determine temporal dynamics and water distributions within xylem tissue. In this study, we found good agreement between MRI measures of pixel brightness to assess xylem liquid water content and the percent loss in hydraulic conductivity (PLC) in response to water stress (P50 values of 2.51 and 2.70 for MRI and PLC, respectively). These data provide strong support that pixel brightness is well correlated to PLC and can be used as a proxy of PLC even when single vessels cannot be resolved on the image. Pressure induced embolism in moderately stressed plants resulted in initial drop of pixel brightness. This drop was followed by brightness gain over 100 min following pressure application suggesting that plants can restore water content in stem after induced embolism. This recovery was limited only to current-year wood ring; older wood did not show signs of recovery within the length of experiment (16 h). In vivo MRI observations of the xylem of moderately stressed (~-0.5 MPa) A. rubrum stems revealed evidence of a spontaneous embolism formation followed by rapid refilling (~30 min). Spontaneous (not induced) embolism formation was observed only once, despite over 60 h of continuous MRI observations made on several plants. Thus this observation provide evidence for the presence of naturally occurring embolism-refilling cycle in A. rubrum, but it is impossible to infer any conclusions in relation to its frequency in nature.
Myla, Subbarao; Bacharach, J Michael; Ansel, Gary M; Dippel, Eric J; McCormick, Daniel J; Popma, Jeffrey J
2010-05-01
The multicenter EPIC (FiberNet Embolic Protection System in Carotid Artery Stenting Trial) single-arm trial evaluated the 30-day outcomes of a new design concept for embolic protection during carotid artery stenting (CAS). Embolic protection filters available for use during CAS include fixed and over-the-wire systems that rely on embolic material capture within a "basket" structure. The FiberNet Embolic Protection System (EPS), which features a very low crossing profile, consists of a three-dimensional fiber-based filter distally mounted on a 0.014 inch guidewire with integrated aspiration during filter retrieval. The trial enrolled 237 patients from 26 centers. Demographics, clinical and lesion characteristics, as well as adverse events through a 30-day follow-up were recorded. The mean age of the patients was 74 years, 64% were male and 20% had symptomatic carotid artery disease. The combined major adverse event (MAE) rate at 30 days for all death, stroke, and myocardial infarction was 3.0%. There were three major strokes (two ischemic and one hemorrhagic) and two minor strokes (both ischemic) for a 2.1% 30-day stroke rate. The procedural technical success rate was 97.5% and macroscopic evidence of debris was reported in 90.9% of the procedures. The FiberNet EPS, used with commercially available stents, produced low stroke rates following CAS in high surgical risk patients presenting with carotid artery disease. The unique filter design including aspiration during retrieval may have contributed to the low 30-day stroke rate reported during CAS in patients considered at high risk for complications following carotid endarterectomy (CEA). Copyright 2010 Wiley-Liss, Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pyra, Krzysztof, E-mail: k.pyra@poczta.fm; Woźniak, Sławomir, E-mail: slavwo7572@gmail.com; Drelich-Zbroja, Anna, E-mail: zbroanna@interia.pl
PurposeThis study aimed to collect confirmatory data in support of the safety and efficiency of the ArtVentive EOS™ for the treatment of the pelvic congestion syndrome (PCS). This study was based on the OCCLUDE 1 Study Protocol approved by the Local Ethics Committee.Materials and MethodsA prospective study carried out in June and July 2014 included 12 women aged 21–48 years (mean 31 years) scheduled for PCS embolization using the ArtVentive EOS™. The inclusion criteria were clinical symptoms of PCS documented by transvaginal Doppler ultrasound and pelvic MRI. The pelvic pain was assessed by VAS score from 0 to 10 (0 represents lackmore » of pain and 10 unbearable pain). A decrease in pelvic pain intensity based on the VAS was considered a clinical success.ResultsSuccessful embolization procedures with ArtVentive EOS™ were performed in 11 out of 12 patients. Nine patients underwent unilateral embolization of the left ovarian vein, and two had bilateral embolization of the ovarian veins. Complete ovarian vein occlusion confirmed by post deployment venography was achieved in all 11 patients. Procedures lasted from 19 to 45 min (average 28 min). Pain intensity decrease was observed in all 11 patients—a decrease of 5.6 points—from 7.3 pre-procedure to 1.6 post-embolization (standard deviation: 0.67). In one case, the left ovarian vein was injured by guide wire manipulation with contrast extravasation—not clinically significant.ConclusionsThe use of ArtVentive EOS™ for occlusion of the ovarian veins in PCS patients is safe and effective.« less
Zwieniecki, Maciej A.; Melcher, Peter J.; Ahrens, Eric T.
2013-01-01
We report results of an analysis of embolism formation and subsequent refilling observed in stems of Acer rubrum L. using magnetic resonance imaging (MRI). MRI is one of the very few techniques that can provide direct non-destructive observations of the water content within opaque biological materials at a micrometer resolution. Thus, it has been used to determine temporal dynamics and water distributions within xylem tissue. In this study, we found good agreement between MRI measures of pixel brightness to assess xylem liquid water content and the percent loss in hydraulic conductivity (PLC) in response to water stress (P50 values of 2.51 and 2.70 for MRI and PLC, respectively). These data provide strong support that pixel brightness is well correlated to PLC and can be used as a proxy of PLC even when single vessels cannot be resolved on the image. Pressure induced embolism in moderately stressed plants resulted in initial drop of pixel brightness. This drop was followed by brightness gain over 100 min following pressure application suggesting that plants can restore water content in stem after induced embolism. This recovery was limited only to current-year wood ring; older wood did not show signs of recovery within the length of experiment (16 h). In vivo MRI observations of the xylem of moderately stressed (~-0.5 MPa) A. rubrum stems revealed evidence of a spontaneous embolism formation followed by rapid refilling (~30 min). Spontaneous (not induced) embolism formation was observed only once, despite over 60 h of continuous MRI observations made on several plants. Thus this observation provide evidence for the presence of naturally occurring embolism-refilling cycle in A. rubrum, but it is impossible to infer any conclusions in relation to its frequency in nature. PMID:23885258
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang Xiaodong, E-mail: wangxde@gmail.com; Erinjeri, Joseph P., E-mail: erinjerj@mskcc.org; Jia Xiaoyu, E-mail: jiax@mskcc.org
2013-08-01
PurposeTo determine if the pattern of retained contrast on immediate postprocedure computed tomography (CT) after particle embolization of hepatic tumors predicts modified Response Evaluation Criteria in Solid Tumors (mRECIST) response.Materials and MethodsThis study was approved by the Institutional Review Board with a waiver of authorization. One hundred four liver tumors were embolized with spherical embolic agents (Embospheres, Bead Block, LC Bead) and polyvinyl alcohol. Noncontrast CT was performed immediately after embolization to assess contrast retention in the targeted tumors, and treatment response was assessed by mRECIST criteria on follow-up CT (average time 9.0 {+-} 7.7 weeks after embolization). Tumor contrastmore » retention (TCR) was determined based on change in Hounsfield units (HUs) of the index tumors between the preprocedure and immediate postprocedure scans; vascular contrast retention (VCR) was rated; and defects in contrast retention (DCR) were also documented. The morphology of residual enhancing tumor on follow-up CT was described as partial, circumferential, or total. Association between TCR variables and tumor response were assessed using multivariate logistic regression.ResultsOf 104 hepatic tumors, 51 (49 %) tumors had complete response (CR) by mRECIST criteria; 23 (22.1 %) had partial response (PR); 21 (20.2 %) had stable disease (SD); and 9 (8.7 %) had progressive disease (PD). By multivariate analysis, TCR, VCR, and tumor size are independent predictors of CR (p = 0.02, 0.05, and 0.005 respectively). In 75 tumors, DCR was found to be an independent predictor of failure to achieve complete response (p < 0.0001) by imaging criteria.ConclusionTCR, VCR, and DCR on immediate posttreatment CT are independent predictors of CR by mRECIST criteria.« less
Low density biodegradable shape memory polyurethane foams for embolic biomedical applications
Singhal, Pooja; Small, Ward; Cosgriff-Hernandez, Elizabeth; Maitland, Duncan J; Wilson, Thomas S
2014-01-01
Low density shape memory polymer foams hold significant interest in the biomaterials community for their potential use in minimally invasive embolic biomedical applications. The unique shape memory behavior of these foams allows them to be compressed to a miniaturized form, which can be delivered to an anatomical site via a transcatheter process, and thereafter actuated to embolize the desired area. Previous work in this field has described the use of a highly covalently crosslinked polymer structure for maintaining excellent mechanical and shape memory properties at the application-specific ultra low densities. This work is aimed at further expanding the utility of these biomaterials, as implantable low density shape memory polymer foams, by introducing controlled biodegradability. A highly covalently crosslinked network structure was maintained by use of low molecular weight, symmetrical and polyfunctional hydroxyl monomers such as Polycaprolactone triol (PCL-t, Mn 900 g), N,N,N0,N0-Tetrakis (hydroxypropyl) ethylenediamine (HPED), and Tris (2-hydroxyethyl) amine (TEA). Control over the degradation rate of the materials was achieved by changing the concentration of the degradable PCL-t monomer, and by varying the material hydrophobicity. These porous SMP materials exhibit a uniform cell morphology and excellent shape recovery, along with controllable actuation temperature and degradation rate. We believe that they form a new class of low density biodegradable SMP scaffolds that can potentially be used as “smart” non-permanent implants in multiple minimally invasive biomedical applications. PMID:24090987
Raymond, J; Iancu, D; Weill, A; Guilbert, F; Bahary, J P; Bojanowski, M; Roy, D
2005-10-05
We attempted to assess clinical results of management of cerebral arteriovenous malformation using a combination of endovascular, surgical and radiotherapeutic approaches. We retrospectively reviewed the angiographic and clinical data on prospectively collected consecutive patients treated by embolization from 1994 to 2004. The general philosophy was to attempt treatment by a combination of approaches only when an angiographic cure was likely or at least possible. The clinical outcome was assessed according to the modified Rankin scale. Although 404 patients were collected, complete files and follow-ups are available for 227 or 56% only. Most patients presented with hemorrhages (53%) or seizures (23%). The final management consisted in embolization alone in 34%, embolization followed by surgery in 47%, embolization and radiotherapy in 16%, and embolization, surgery and radiotherapy in 3% of patients. The embolization procedure itself could lead to an angiographic cure in only 16% of patients. When the management strategy could be completed, the cure rate increased to 66%. Complications of embolization occurred in 22.6% of patients. Overall clinical outcome was excellent (Rankin 0) in 43%, good (Rankin 1) in 38%, fair (Rankin 2) in 10%, poor (Rankin 3-5) in 2%, and the death rate was 7%. A combined strategy initially designed to provide angiographic cures cannot be completed in a significant number of patients; the total morbidity of treatment remains significant. There is no scientific evidence that cerebral arteriovenous malformations should be treated, and no clinical trial to prove that one approach is better than the other. Various treatment protocols have been proposed on empirical grounds. Small lesions can often be eradicated, with surgery when lesions are superficial, or with radiation therapy for deeper ones. There has been little controversy regarding therapeutic indications in these patients (1). The management of larger AVMs, sometimes in more eloquent locations, is much more difficult and controversial (2-4). Endovascular approaches have initially been developed to meet this challenge (5,6). It became quickly evident that embolization alone would rarely suffice to completely cure these lesions. The philosophy behind combined approaches is founded on 2 opinions: 1) There is no proven value of partial embolization, not even "partial benefits", and treatment should aim at an angiographic cure (7) and 2) By appropriately tailoring all available tools to each situation, such a cure could be reached with minimum or reasonable risks. We have used such a combined strategy for more than a decade now. Endovascular techniques and materials have evolved, and it is perhaps possible today to reach a cure by embolization alone in a larger proportion of patients than before (8). Aggressive embolizations, aiming for an endovascular cure, even sometimes in large lesions, have recently been promoted for their power or criticized for their risks (9). But before evaluating the advantages and inconveniences of new treatments, it may be wise to review the results we could achieve with a conventional approach combining endovascular, surgical and radiotherapeutic techniques.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jambon, E.; Petitpierre, F.; Brizzi, V.
PurposeTo retrospectively investigate the safety and efficacy of hybrid proximal coiling of various medium-sized vessels (4 to 8 mm) using the Penumbra Occlusion Device (POD).Materials and MethodsFrom October 2014 to February 2016, 37 proximal embolizations were performed with PODs in 36 patients (mean age: 50.8, range: 10–86; 29 male, 7 female). Vessel occlusions were achieved under fluoroscopic guidance using a 2.7 French microcatheter. Among the 36 vessels targeted, 16 were splenic arteries, 11 renal arteries, 4 mesenteric arteries, 3 arteriovenous fistulae, 1 iliac artery, and 1 gonadal vein. Intermittent follow-up angiography was performed to assess the flow for final occlusion. Outcomesmore » and complications were assessed by clinical and/or imaging follow-up.ResultsTo produce proximal occlusion of the intended vessels, the POD was used alone in 19 embolizations (51.4 %). In 12 procedures (32.4 %), POD was used as a coil constrainer to secure the coil construct. In 6 procedures (16.2 %), additional embolic devices were used to achieve vessel occlusion after initial POD deployment. After a mean follow-up of 3.2 months, no POD migration was observed but two complications occurred (5.4 %): one post embolic syndrome and one extensive infarction with splenic abscess.ConclusionThe POD system allows safe and effective proximal embolization of medium-sized vessels in a variety of clinical settings.« less
Pathophysiological effect of fat embolism in a canine model of pulmonary contusion.
Elmaraghy, A W; Aksenov, S; Byrick, R J; Richards, R R; Schemitsch, E H
1999-08-01
The objective of this study was to determine the individual and combined effects of pulmonary contusion and fat embolism on the hemodynamics and pulmonary pathophysiology in a canine model of acute traumatic pulmonary injury. After a thoracotomy, twenty-one skeletally mature dogs were randomly assigned to one of three groups. Unilateral pulmonary contusion alone was produced in Group 1 (seven dogs); pulmonary contusion and fat embolism, in Group 2 (seven dogs); and fat embolism alone, in Group 3 (seven dogs). Pulmonary contusion was produced by standardized compression of the left lung with a piezoelectric force transducer. Fat embolism was produced by femoral and tibial reaming followed by pressurization of the intramedullary canals. Cardiac output, systolic blood pressure, peak airway pressure, pulmonary arterial pressure, pulmonary capillary wedge pressure, partial pressure of arterial oxygen, and partial pressure of carbon dioxide were monitored for all groups. From these data, several outcome parameters were calculated: total thoracic compliance, alveolar-arterial oxygen gradient, and ratio of partial pressure of arterial oxygen to fractional inspired oxygen concentration. All of the dogs were killed after eight hours, and tissue samples were obtained from the brain, kidneys, and lungs for histological analysis. Lung samples were assigned scores for pulmonary edema (the presence of fluid in the alveoli) and inflammation (the presence of neutrophils or hyaline membranes, or both). The percentage of the total area occupied by fat was determined. Pulmonary contusion alone caused a significant increase in the alveolar-arterial oxygen gradient but only after seven hours (p = 0.034). Fat embolism alone caused a significant transient decrease in systolic blood pressure (p = 0.001) and a significant transient increase in pulmonary arterial pressure (p = 0.01) and pulmonary capillary wedge pressure (p = 0.015). Fat embolism alone also caused a significant sustained decrease in the ratio of partial pressure of arterial oxygen to fractional inspired oxygen concentration (p = 0.0001) and a significant increase in the alveolar-arterial oxygen gradient (p = 0.0001). The combination of pulmonary contusion and fat embolism caused a significant transient increase in pulmonary capillary wedge pressure (p = 0.0013) as well as a significant sustained decrease in partial pressure of arterial oxygen (p = 0.0001) and a significant decrease in systolic blood pressure (p = 0.001) that lasted for an hour. Pulmonary contusion followed by fat embolism caused a significant increase in peak airway pressure (p = 0.015), alveolar-arterial oxygen gradient (p = 0.0001), and pulmonary arterial pressure (p = 0.01), and these effects persisted for five hours. Total thoracic compliance was decreased 6.4 percent by pulmonary contusion alone, 4.6 percent by fat embolism alone, and 23.5 percent by pulmonary contusion followed by fat embolism. The ratio of partial pressure of arterial oxygen to fractional inspired oxygen concentration was decreased 23.7 percent by pulmonary contusion alone, 52.3 percent by fat embolism alone, and 65.8 percent by pulmonary contusion followed by fat embolism. The mean pulmonary edema score was significantly higher with the combined injury than with either injury alone (p = 0.0001). None of the samples from the lungs demonstrated inflammation. Fat embolism combined with pulmonary contusion resulted in a significantly greater mean percentage of the area occupied by fat in the noncontused right lung than in the contused left lung (p = 0.001); however, no significant difference between the right and left lungs could be detected with fat embolism alone. The mean percentage of the glomerular and cerebral areas occupied by fat was greater with fat embolism combined with pulmonary contusion than with fat embolism alone (p = 0.0001 and p = 0.01, respectively). (ABSTRACT TRUNCATED)
Dresden, Scott; Mitchell, Patricia; Rahimi, Layla; Leo, Megan; Rubin-Smith, Julia; Bibi, Salma; White, Laura; Langlois, Breanne; Sullivan, Alison; Carmody, Kristin
2014-01-01
The objective of this study was to determine the diagnostic performance of right ventricular dilatation identified by emergency physicians on bedside echocardiography in patients with a suspected or confirmed pulmonary embolism. The secondary objective included an exploratory analysis of the predictive value of a subgroup of findings associated with advanced right ventricular dysfunction (right ventricular hypokinesis, paradoxical septal motion, McConnell's sign). This was a prospective observational study using a convenience sample of patients with suspected (moderate to high pretest probability) or confirmed pulmonary embolism. Participants had bedside echocardiography evaluating for right ventricular dilatation (defined as right ventricular to left ventricular ratio greater than 1:1) and right ventricular dysfunction (right ventricular hypokinesis, paradoxical septal motion, or McConnell's sign). The patient's medical records were reviewed for the final reading on all imaging, disposition, hospital length of stay, 30-day inhospital mortality, and discharge diagnosis. Thirty of 146 patients had a pulmonary embolism. Right ventricular dilatation on echocardiography had a sensitivity of 50% (95% confidence interval [CI] 32% to 68%), a specificity of 98% (95% CI 95% to 100%), a positive predictive value of 88% (95% CI 66% to 100%), and a negative predictive value of 88% (95% CI 83% to 94%). Positive and negative likelihood ratios were determined to be 29 (95% CI 6.1% to 64%) and 0.51 (95% CI 0.4% to 0.7%), respectively. Ten of 11 patients with right ventricular hypokinesis had a pulmonary embolism. All 6 patients with McConnell's sign and all 8 patients with paradoxical septal motion had a diagnosis of pulmonary embolism. There was a 96% observed agreement between coinvestigators and principal investigator interpretation of images obtained and recorded. Right ventricular dilatation and right ventricular dysfunction identified on emergency physician performed echocardiography were found to be highly specific for pulmonary embolism but had poor sensitivity. Bedside echocardiography is a useful tool that can be incorporated into the algorithm of patients with a moderate to high pretest probability of pulmonary embolism. Copyright © 2013 American College of Emergency Physicians. Published by Mosby, Inc. All rights reserved.
First Human Experience with Directly Image-able Iodinated Embolization Microbeads
DOE Office of Scientific and Technical Information (OSTI.GOV)
Levy, Elliot B., E-mail: levyeb@cc.nih.gov; Krishnasamy, Venkatesh P.; Lewis, Andrew L.
PurposeTo describe first clinical experience with a directly image-able, inherently radio-opaque microspherical embolic agent for transarterial embolization of liver tumors.MethodologyLC Bead LUMI™ is a new product based upon sulfonate-modified polyvinyl alcohol hydrogel microbeads with covalently bound iodine (~260 mg I/ml). 70–150 μ LC Bead LUMI™ iodinated microbeads were injected selectively via a 2.8 Fr microcatheter to near complete flow stasis into hepatic arteries in three patients with hepatocellular carcinoma, carcinoid, or neuroendocrine tumor. A custom imaging platform tuned for LC LUMI™ microbead conspicuity using a cone beam CT (CBCT)/angiographic C-arm system (Allura Clarity FD20, Philips) was used along with CBCT embolization treatment planning software (EmboGuide,more » Philips).ResultsLC Bead LUMI™ image-able microbeads were easily delivered and monitored during the procedure using fluoroscopy, single-shot radiography (SSD), digital subtraction angiography (DSA), dual-phase enhanced and unenhanced CBCT, and unenhanced conventional CT obtained 48 h after the procedure. Intra-procedural imaging demonstrated tumor at risk for potential under-treatment, defined as paucity of image-able microbeads within a portion of the tumor which was confirmed at 48 h CT imaging. Fusion of pre- and post-embolization CBCT identified vessels without beads that corresponded to enhancing tumor tissue in the same location on follow-up imaging (48 h post).ConclusionLC Bead LUMI™ image-able microbeads provide real-time feedback and geographic localization of treatment in real time during treatment. The distribution and density of image-able beads within a tumor need further evaluation as an additional endpoint for embolization.« less
[Chronic outcome of patients with paroxysmal atrial fibrillation post catheter ablation].
Lin, Yu-bi; Xia, Yun-long; Gao, Lian-jun; Chu, Zhen-liang; Cong, Pei-xin; Chang, Dong; Yin, Xiao-meng; Zhang, Shu-long; Yang, Dong-Hui; Yang, Yan-Zong
2009-12-01
High short-term successful rate was reported for catheter ablation in patients with paroxysmal atrial fibrillation (AF), we analyzed the long-term outcome (success rate, anticoagulation therapy and embolism event, anti-arrhythmic therapy and death post procedure) of catheter ablation for paroxysmal AF in this study. From January 2000 to December 2004, 106 consecutive patients with drug-refractory paroxysmal AF underwent catheter ablation and were followed-up for (60.7 + or - 11.8) months. Segmental pulmonary vein isolation (SPVI) was routinely performed by radiofrequency energy under the guidance of circular mapping catheter. The patients were followed up with 24 h-holter, ECG, telephone or letter. Data on recurrence of AF, the anticoagulation medication and the incidence of embolism, anti-arrhythmic therapy were obtained. There were 9 patients lost to follow up. In the remaining 97 patients [65 males, (54.8 + or - 11.2) years old], 3 cases died from cancer, sinus rhythm was maintained in 68 patients (Group S, 72.3%) and AF recurrence evidenced in 26 patients (Group R, 27.7%). In Group S, 56 patients (82.4%) discontinued anticoagulation medication, and 12 patients continued to take aspirin. There was no embolism event in Group S during follow-up. In Group R, 1 patient continued to take warfarin; 11 patients continued to take aspirin and 2 patients suffered from cerebral embolism. Anticoagulation medication was discontinued in 14 patients (53.8%) and 1 patient suffered form cerebral embolism. The incidence of embolism event in Group R is significantly higher than in Group S (P < 0.01). More patients discontinued anti-arrhythmic medication in Group S than in Group R (80.9% vs. 56.0%, P < 0.05). Catheter ablation is associated with satisfactory long-term success rate, reduced anti-arrhythmia medication, improved quality of life in patients with paroxysmal AF.
How the climate limits the wood density of angiosperms
NASA Astrophysics Data System (ADS)
Choi, Jin Woo; Kim, Ho-Young
2017-11-01
Flowering trees have various types of wood structure to perform multiple functions under their environmental conditions. In addition to transporting water from the roots to the canopy and providing mechanical support, the structure should provide resistance to embolism to maintain soil-plant-atmosphere continuum. By investigating existing data of the resistivity to embolism and wood density of 165 angiosperm species, here we show that the climate can limit the intrinsic properties of trees. Trees living in the dry environments require a high wood density to slow down the pressure decrease as it loses water relatively fast by evaporation. However, building too much tissues will result in the decrease of hydraulic conductivity and moisture concentration around mesophyll cells. To rationalize the biologically observed lower bound of the wood density, we construct a mechanical model to predict the wood density as a function of the vulnerability to embolism and the time for the recovery. Also, we build an artificial system using hydrogel microchannels that can test the probability of embolism as a function of conduit distributions. Our theoretical prediction is shown to be consistent with the results obtained from the artificial system and the biological data.
Transcatheter Embolization of a Renal Artery Aneurysm Using Ethylene Vinyl Alcohol Copolymer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rautio, Riitta, E-mail: riitta.rautio@tyks.fi; Haapanen, Arto
2007-04-15
Our aim was to treat a clinically silent renal artery aneurysm. The patient was a 76-year-old man with elevated prostate-specific antigen and prostata biopsies with a gradus II-III adenocarcinoma who was incidentally found to have an aneurysm in his right renal artery. We performed a successful transcatheter embolization of the aneurysm using ethylene vinyl alcohol copolymer (Onyx). To avoid migration of the liquid material into the parent artery, a balloon was inflated in the orifice of the neck of the aneurysm while the liquid was injected. Five-month follow-up computed tomography (CT) imaging confirmed total occlusion of the aneurysm.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Singhal, Pooja
Shape memory polymers (SMPs) are a rapidly emerging class of smart materials that can be stored in a deformed temporary shape, and can actively return to their original shape upon application of an external stimulus such as heat, pH or light. This behavior is particularly advantageous for minimally invasive biomedical applications comprising embolic/regenerative scaffolds, as it enables a transcatheter delivery of the device to the target site. The focus of this work was to exploit this shape memory behavior of polyurethanes, and develop an efficient embolic SMP foam device for the treatment of intracranial aneurysms.In summary, this work reports amore » novel family of ultra low density polymer foams which can be delivered via a minimally invasive surgery to the aneurysm site, actuated in a controlled manner to efficiently embolize the aneurysm while promoting physiological fluid/blood flow through the reticulated/open porous structure, and eventually biodegrade leading to complete healing of the vasculature.« less
Kim, Sang Heum; Kim, Tae Gon; Kong, Min Ho
2017-09-01
The Onyx system has been well established in recent years as a very important material in the treatment of arteriovenous malformations (AVMs). When using the Onyx, it is essential to wait for the creation of a plug around the tip of the catheter, which enables the effective forward penetration of Onyx. Recent reports have shown that the introduction of a dimethyl sulfoxide compatible dual-lumen balloon microcatheter improves the efficiency of AVM embolization. We report our recent experience of two cases of intracranial AVM embolization using Onyx and the transarterial balloon-assisted technique. In both cases, the procedures were successfully performed and the nidus of the AVM was totally occluded in a relatively short time. This technique may enable immediate forward flow and penetration of Onyx without concern about reflux. It may also reduce the procedure time and increase the angiographic occlusion rate. Navigation of the dual-lumen balloon microcatheter nevertheless remains a challenge.
Kim, Sang Heum; Kong, Min Ho
2017-01-01
The Onyx system has been well established in recent years as a very important material in the treatment of arteriovenous malformations (AVMs). When using the Onyx, it is essential to wait for the creation of a plug around the tip of the catheter, which enables the effective forward penetration of Onyx. Recent reports have shown that the introduction of a dimethyl sulfoxide compatible dual-lumen balloon microcatheter improves the efficiency of AVM embolization. We report our recent experience of two cases of intracranial AVM embolization using Onyx and the transarterial balloon-assisted technique. In both cases, the procedures were successfully performed and the nidus of the AVM was totally occluded in a relatively short time. This technique may enable immediate forward flow and penetration of Onyx without concern about reflux. It may also reduce the procedure time and increase the angiographic occlusion rate. Navigation of the dual-lumen balloon microcatheter nevertheless remains a challenge. PMID:29159158
Zehtabi, Fatemeh; Ispas-Szabo, Pompilia; Djerir, Djahida; Sivakumaran, Lojan; Annabi, Borhane; Soulez, Gilles; Mateescu, Mircea Alexandru; Lerouge, Sophie
2017-12-01
The success of endovascular repair of abdominal aortic aneurysms remains limited due to the development of endoleaks. Sac embolization has been proposed to manage endoleaks, but current embolizing materials are associated with frequent recurrence. An injectable agent that combines vascular occlusion and sclerosing properties has demonstrated promise for the treatment of endoleaks. Moreover, the inhibition of aneurysmal wall degradation via matrix metalloproteinases (MMPs) may further prevent aneurysm progression. Thus, an embolization agent that promotes occlusion, MMP inhibition and endothelial ablation was hypothesized to provide a multi-faceted approach for endoleak treatment. In this study, an injectable, occlusive chitosan (CH) hydrogel containing doxycycline (DOX)-a sclerosant and MMP inhibitor-was developed. Several CH-DOX hydrogel formulations were characterized for their mechanical and sclerosing properties, injectability, DOX release rate, and MMP inhibition. An optimized formulation was assessed for its short-term ability to occlude blood vessels in vivo. All formulations were injectable and gelled rapidly at body temperature. Only hydrogels prepared with 0.075M sodium bicarbonate and 0.08M phosphate buffer as the gelling agent presented sufficient mechanical properties to immediately impede physiological flow. DOX release from this gel was in a two-stage pattern: a burst release followed by a slow continuous release. Released DOX was bioactive and able to inhibit MMP-2 activity in human glioblastoma cells. Preliminary in vivo testing in pig renal arteries showed immediate and delayed embolization success of 96% and 86%, respectively. Altogether, CH-DOX hydrogels appear to be promising new multifunctional embolic agents for the treatment of endoleaks. An injectable embolizing chitosan hydrogel releasing doxycycline (DOX) was developed as the first multi-faceted approach for the occlusion of blood vessels. It combines occlusive properties with DOX sclerosing and MMP inhibition properties, respectively known to prevent recanalization process and to counteract the underlying pathophysiology of vessel wall degradation and aneurysm progression. After drug release, the biocompatible scaffold can be invaded by cells and slowly degrade. Local DOX delivery requires lower drug amount and decreases risks of side effects compared to systemic administration. This new gel could be used for the prevention or treatment of endoleaks after endovascular aneurysm repair, but also for the embolization of other blood vessels such as venous or vascular malformations. Copyright © 2017 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Lillaney, Prasheel V.; Yang, Jeffrey K.; Losey, Aaron D.; Martin, Alastair J.; Cooke, Daniel L.; Thorne, Bradford R. H.; Barry, David C.; Chu, Andrew; Stillson, Carol; Do, Loi; Arenson, Ronald L.; Saeed, Maythem; Wilson, Mark W.
2016-01-01
Purpose To assess the feasibility of a magnetically assisted remote-controlled (MARC) catheter system under magnetic resonance (MR) imaging guidance for performing a simple endovascular procedure (ie, renal artery embolization) in vivo and to compare with x-ray guidance to determine the value of MR imaging guidance and the specific areas where the MARC system can be improved. Materials and Methods In concordance with the Institutional Animal Care and Use Committee protocol, in vivo renal artery navigation and embolization were tested in three farm pigs (mean weight 43 kg ± 2 [standard deviation]) under real-time MR imaging at 1.5 T. The MARC catheter device was constructed by using an intramural copper-braided catheter connected to a laser-lithographed saddle coil at the distal tip. Interventionalists controlled an in-room cart that delivered electrical current to deflect the catheter in the MR imager. Contralateral kidneys were similarly embolized under x-ray guidance by using standard clinical catheters and guidewires. Changes in renal artery flow and perfusion were measured before and after embolization by using velocity-encoded and perfusion MR imaging. Catheter navigation times, renal parenchymal perfusion, and renal artery flow rates were measured for MR-guided and x-ray–guided embolization procedures and are presented as means ± standard deviation in this pilot study. Results Embolization was successful in all six kidneys under both x-ray and MR imaging guidance. Mean catheterization time with MR guidance was 93 seconds ± 56, compared with 60 seconds ± 22 for x-ray guidance. Mean changes in perfusion rates were 4.9 au/sec ± 0.8 versus 4.6 au/sec ± 0.6, and mean changes in renal flow rate were 2.1 mL/min/g ± 0.2 versus 1.9 mL/min/g ± 0.2 with MR imaging and x-ray guidance, respectively. Conclusion The MARC catheter system is feasible for renal artery catheterization and embolization under real-time MR imaging in vivo, and quantitative physiologic measures under MR imaging guidance were similar to those measured under x-ray guidance, suggesting that the MARC catheter system could be used for endovascular procedures with interventional MR imaging. © RSNA, 2016 PMID:27019290
Lillaney, Prasheel V; Yang, Jeffrey K; Losey, Aaron D; Martin, Alastair J; Cooke, Daniel L; Thorne, Bradford R H; Barry, David C; Chu, Andrew; Stillson, Carol; Do, Loi; Arenson, Ronald L; Saeed, Maythem; Wilson, Mark W; Hetts, Steven W
2016-10-01
Purpose To assess the feasibility of a magnetically assisted remote-controlled (MARC) catheter system under magnetic resonance (MR) imaging guidance for performing a simple endovascular procedure (ie, renal artery embolization) in vivo and to compare with x-ray guidance to determine the value of MR imaging guidance and the specific areas where the MARC system can be improved. Materials and Methods In concordance with the Institutional Animal Care and Use Committee protocol, in vivo renal artery navigation and embolization were tested in three farm pigs (mean weight 43 kg ± 2 [standard deviation]) under real-time MR imaging at 1.5 T. The MARC catheter device was constructed by using an intramural copper-braided catheter connected to a laser-lithographed saddle coil at the distal tip. Interventionalists controlled an in-room cart that delivered electrical current to deflect the catheter in the MR imager. Contralateral kidneys were similarly embolized under x-ray guidance by using standard clinical catheters and guidewires. Changes in renal artery flow and perfusion were measured before and after embolization by using velocity-encoded and perfusion MR imaging. Catheter navigation times, renal parenchymal perfusion, and renal artery flow rates were measured for MR-guided and x-ray-guided embolization procedures and are presented as means ± standard deviation in this pilot study. Results Embolization was successful in all six kidneys under both x-ray and MR imaging guidance. Mean catheterization time with MR guidance was 93 seconds ± 56, compared with 60 seconds ± 22 for x-ray guidance. Mean changes in perfusion rates were 4.9 au/sec ± 0.8 versus 4.6 au/sec ± 0.6, and mean changes in renal flow rate were 2.1 mL/min/g ± 0.2 versus 1.9 mL/min/g ± 0.2 with MR imaging and x-ray guidance, respectively. Conclusion The MARC catheter system is feasible for renal artery catheterization and embolization under real-time MR imaging in vivo, and quantitative physiologic measures under MR imaging guidance were similar to those measured under x-ray guidance, suggesting that the MARC catheter system could be used for endovascular procedures with interventional MR imaging. (©) RSNA, 2016.
Vinsonneau, U; Leblanc, A; Buchet, J-F; Pangnarind-Heintz, V; Le Gal, G; Rohel, G; Paleiron, N; Piquemal, M; Blanchard, C; Zagnoli, F; Paule, P
2014-09-01
Embolism of cardiac origin accounts for around 20% of ischemic strokes. ECG and transthoracic echocardiography (TTE) are commonly obtained during the evaluation of patient of ischemic stroke but specific indications for the transesophageal (TEE) echocardiography and 24-hour Holter ECG (Holter) remain uncertain. The aim of this study is to report the contribution of TTE, TEE and Holter performed as a routine during the evaluation of patients with ischemic stroke (IS) or transient ischemic attack (TIA). This is a retrospective single-center study of 220 patients hospitalized between 1st January 2007 and 31st December 2010 for a first IS or TIA. One hundred and forty-three IS and 77 TIA are identified. The average age of patients was 66 years (18-88 years). TTE/TEE/24-hour Holter allowed the diagnosis of cardiac sources of embolism in 135 patents (61.3%). TTE/TEE identified potential source of cardiogenic embolism in 126 patients (52.2%). Twenty four-hour Holter ECG tracked supraventricular arrhythmia in 15 patients (6.7%), 9 (4%) which had non-contributory ultrasound assessment. The systematic implementation of TTE/TEE/Holter is useful for identifying potential sources of cardiogenic embolism. The performance of TEE remains above the TTE. Holter should be recommended because it is a cost effective and non-invasive tool. Copyright © 2014 Elsevier Masson SAS. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sommer, C. M., E-mail: christof.sommer@med.uni-heidelberg.de; Kortes, N.; Zelzer, S.
2011-02-15
The purpose of this study was to evaluate the effect of renal artery embolization with small and narrowly calibrated microparticles on the coagulation diameter, volume, and shape of radiofrequency ablations (RFAs) in porcine kidneys. Forty-eight RFAs were performed in 24 kidneys of 12 pigs. In 6 animals, bilateral renal artery embolization was performed with small and narrowly calibrated microparticles. Upper and lower kidney poles were ablated with identical system parameters. Applying three-dimensional segmentation software, RFAs were segmented on registered 2 mm-thin macroscopic slices. Length, depth, width, volume{sub s}egmented, and volume{sub c}alculated were determined to describe the size of the RFAs.more » To evaluate the shape of the RFAs, depth-to-width ratio (perfect symmetry-to-lesion length was indicated by a ratio of 1), sphericity ratio (perfect sphere was indicated by a sphericity ratio of 1), eccentricity (perfect sphere was indicated by an eccentricity of 0), and circularity (perfect circle was indicated by a circularity of 1) were determined. Embolized compared with nonembolized RFAs showed significantly greater depth (23.4 {+-} 3.6 vs. 17.2 {+-} 1.8 mm; p < 0.001) and width (20.1 {+-} 2.9 vs. 12.6 {+-} 3.7 mm; p < 0.001); significantly larger volume{sub s}egmented (8.6 {+-} 3.2 vs. 3.0 {+-} 0.7 ml; p < 0.001) and volume{sub c}alculated (8.4 {+-} 3.0 ml vs. 3.3 {+-} 1.1 ml; p < 0.001); significantly lower depth-to-width (1.17 {+-} 0.10 vs. 1.48 {+-} 0.44; p < 0.05), sphericity (1.55 {+-} 0.44 vs. 1.96 {+-} 0.43; p < 0.01), and eccentricity (0.84 {+-} 0.61 vs. 1.73 {+-} 0.91; p < 0.01) ratios; and significantly greater circularity (0.62 {+-} 0.14 vs. 0.45 {+-} 0.16; p < 0.01). Renal artery embolization with small and narrowly calibrated microparticles affected the coagulation diameter, volume, and shape of RFAs in porcine kidneys. Embolized RFAs were significantly larger and more spherical compared with nonembolized RFAs.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shimohira, Masashi, E-mail: mshimohira@gmail.com; Hashizume, Takuya; Sasaki, Shigeru
PurposeTo assess the usefulness of transcatheter arterial embolization (TAE) for the hepatic arterial injury related to percutaneous transhepatic portal intervention (PTPI).Materials and MethodsFifty-four patients, 32 males and 22 females with a median age of 68 years (range 43–82 years), underwent PTPI. The procedures consisted of 33 percutaneous transhepatic portal vein embolizations, 19 percutaneous transhepatic variceal embolizations, and 2 percutaneous transhepatic portal venous stent placements. Two patients with gastric varices underwent percutaneous transhepatic variceal embolization twice because of recurrence. Therefore, the total number of procedures was 56. Among them, hepatic arterial injury occurred in 6 PTPIs in 5 patients, and TAE was performed.more » We assessed technical success, complications related to TAE, and clinical outcome. Technical success was defined as the disappearance of findings due to hepatic arterial injury on digital subtraction angiography.ResultsAs hepatic arterial injuries, 4 extravasations and 2 arterioportal shunts developed. All TAEs were performed successfully. The technical success rate was 100 %. Complication of TAE occurred in 5 of 6 TAEs; 3 were focal liver infarction, not requiring further treatment, and 2 were biloma that required percutaneous drainage. Five TAEs in 4 patients were performed immediately after the PTPI, and these 4 patients were alive. However, one TAE was performed 10 h later, and the patient died due to multiple organ failure 2 months later although TAE was successful.ConclusionTAE is a useful treatment for hepatic arterial injury related to PTPI. However, it should be performed at an early stage.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Powerski, Maciej, E-mail: maciej.powerski@med.ovgu.de; Busse, Anke, E-mail: anke.busse@med.ovgu.de; Seidensticker, Max, E-mail: max.seidensticker@med.ovgu.de
PurposePrior to radioembolization (RE) of hepatic tumors, many centers prophylactically occlude the cystic artery (CA) during evaluation angiography (EVA) to prevent radiation-induced cholecystitis. There is no conclusive evidence for the protective effect of CA embolization and it bears the risk of inducing ischemic cholecystitis. The aim of this study is to evaluate the justification for CA embolization by comparing clinical and morphologic imaging parameters between patients undergoing coil occlusion of the cystic artery (COCA) and those with uncoiled CA (UCCA).Materials and MethodsRetrospective comparison of 37 patients with UCCA versus 68 patients with COCA in terms of clinical findings (CRP, leukocytemore » count, body temperature, upper abdominal pain) and morphologic imaging parameters associated with cholecystitis (gallbladder (GB) wall thickness, free fluid in GB bed, bremsstrahlung SPECT) after EVA, after RE, and at 6-week follow-up.ResultsAt none of the 3 time points (EVA, RE, 6-week follow-up) was there any significant difference in CRP, leukocyte count, body temperature, or upper abdominal pain between the UCCA and COCA group. There was also no significant difference between the two groups with regard to GB wall thickness, fluid in the GB bed, and bremsstrahlung in SPECT. One patient of the UCCA group and two patients of the COCA developed cholecystitis requiring treatment.ConclusionComparison of clinical and imaging findings between patients with and without CA embolization prior to RE identified no predictors of radiogenic or ischemic cholecystitis after RE. Our study provides no evidence for a benefit of prophylactic CA embolization before RE.« less
Clinical Safety of Bariatric Arterial Embolization: Preliminary Results of the BEAT Obesity Trial.
Weiss, Clifford R; Akinwande, Olaguoke; Paudel, Kaylan; Cheskin, Lawrence J; Holly, Brian; Hong, Kelvin; Fischman, Aaron M; Patel, Rahul S; Shin, Eun J; Steele, Kimberley E; Moran, Timothy H; Kaiser, Kristen; Park, Amie; Shade, David M; Kraitchman, Dara L; Arepally, Aravind
2017-05-01
Purpose To conduct a pilot prospective clinical trial to evaluate the feasibility, safety, and short-term efficacy of bariatric embolization, a recently developed endovascular procedure for the treatment of obesity, in patients with severe obesity. Materials and Methods This is an institutional review board- and U.S. Food and Drug Administration-approved prospective physician-initiated investigational device exemption study. This phase of the study ran from June 2, 2014, to August 4, 2015. Five severely obese patients (four women, one man) who were 31-49 years of age and who had a mean body mass index of 43.8 kg/m 2 ± 2.9 with no clinically important comorbidities were enrolled in this study. Transarterial embolization of the gastric fundus with fluoroscopic guidance was performed with 300-500-μm Embosphere microspheres. The primary end point was 30-day adverse events (AEs). The secondary end points included short-term weight loss, serum obesity-related hormone levels, hunger and satiety assessments, and quality of life (QOL) surveys, reported up to 3 months. Simple statistics of central tendencies and variability were calculated. No hypothesis testing was performed. Results The left gastric artery, with or without the gastroepiploic artery, was embolized in five patients, with a technical success rate of 100%. There were no major AEs. There were two minor AEs-subclinical pancreatitis and a mucosal ulcer that had healed by the time of 3-month endoscopy. A hospital stay of less than 48 hours for routine supportive care was provided for three patients. Mean excess weight loss of 5.9% ± 2.4 and 9.0% ± 4.1 was noted at 1 month and at 3 months, respectively. Mean change in serum ghrelin was 8.7% ± 34.7 and -17.5% ± 29 at 1 month and 3 months, respectively. Mean changes in serum glucagon-like peptide 1 and peptide YY were 106.6% ± 208.5 and 17.8% ± 54.8 at 1 month. There was a trend toward improvement in QOL parameters. Hunger/appetite scores decreased in the first 2 weeks after the procedure and then rose without reaching preprocedure levels. Conclusion Bariatric embolization is feasible and appears to be well tolerated in severely obese patients. In this small patient cohort, it appears to induce appetite suppression and may induce weight loss. Further expansion of this study will provide more insight into the long-term safety and efficacy of bariatric embolization. © RSNA, 2017 Online supplemental material is available for this article.
Clinical Safety of Bariatric Arterial Embolization: Preliminary Results of the BEAT Obesity Trial
Akinwande, Olaguoke; Paudel, Kaylan; Cheskin, Lawrence J.; Holly, Brian; Hong, Kelvin; Fischman, Aaron M.; Patel, Rahul S.; Shin, Eun J.; Steele, Kimberley E.; Moran, Timothy H.; Kaiser, Kristen; Park, Amie; Shade, David M.; Kraitchman, Dara L.; Arepally, Aravind
2017-01-01
Purpose To conduct a pilot prospective clinical trial to evaluate the feasibility, safety, and short-term efficacy of bariatric embolization, a recently developed endovascular procedure for the treatment of obesity, in patients with severe obesity. Materials and Methods This is an institutional review board– and U.S. Food and Drug Administration–approved prospective physician-initiated investigational device exemption study. This phase of the study ran from June 2, 2014, to August 4, 2015. Five severely obese patients (four women, one man) who were 31–49 years of age and who had a mean body mass index of 43.8 kg/m2 ± 2.9 with no clinically important comorbidities were enrolled in this study. Transarterial embolization of the gastric fundus with fluoroscopic guidance was performed with 300–500-μm Embosphere microspheres. The primary end point was 30-day adverse events (AEs). The secondary end points included short-term weight loss, serum obesity-related hormone levels, hunger and satiety assessments, and quality of life (QOL) surveys, reported up to 3 months. Simple statistics of central tendencies and variability were calculated. No hypothesis testing was performed. Results The left gastric artery, with or without the gastroepiploic artery, was embolized in five patients, with a technical success rate of 100%. There were no major AEs. There were two minor AEs—subclinical pancreatitis and a mucosal ulcer that had healed by the time of 3-month endoscopy. A hospital stay of less than 48 hours for routine supportive care was provided for three patients. Mean excess weight loss of 5.9% ± 2.4 and 9.0% ± 4.1 was noted at 1 month and at 3 months, respectively. Mean change in serum ghrelin was 8.7% ± 34.7 and −17.5% ± 29 at 1 month and 3 months, respectively. Mean changes in serum glucagon-like peptide 1 and peptide YY were 106.6% ± 208.5 and 17.8% ± 54.8 at 1 month. There was a trend toward improvement in QOL parameters. Hunger/appetite scores decreased in the first 2 weeks after the procedure and then rose without reaching preprocedure levels. Conclusion Bariatric embolization is feasible and appears to be well tolerated in severely obese patients. In this small patient cohort, it appears to induce appetite suppression and may induce weight loss. Further expansion of this study will provide more insight into the long-term safety and efficacy of bariatric embolization. © RSNA, 2017 Online supplemental material is available for this article. PMID:28195823
Intrahepatic Flow Redistribution in Patients Treated with Radioembolization
DOE Office of Scientific and Technical Information (OSTI.GOV)
Spreafico, Carlo, E-mail: carlo.spreafico@istitutotumori.mi.it; Morosi, Carlo, E-mail: carlo.morosi@istitutotumori.mi.it; Maccauro, Marco, E-mail: marco.maccauro@istitutotumori.mi.it
2015-04-15
IntroductionIn planning Yttrium-90 ({sup 90}Y)-radioembolizations, strategy problems arise in tumours with multiple arterial supplies. We aim to demonstrate that tumours can be treated via one main feeding artery achieving flow redistribution by embolizing accessory vessels.MethodsOne hundred {sup 90}Y-radioembolizations were performed on 90 patients using glass microspheres. In 19 lesions/17 patients, accessory branches were found feeding a minor tumour portion and embolized. In all 17 patients, the assessment of the complete perfusion was obtained by angiography and single photon emission computerized tomography–computerized tomography (SPECT–CT). Dosimetry, toxicity, and tumor response rate of the patients treated after flow redistribution were compared with themore » 83 standard-treated patients. Seventeen lesions in 15 patients with flow redistribution were chosen as target lesions and evaluated according to mRECIST criteria.ResultsIn all patients, the complete tumor perfusion was assessed immediately before radioembolization by angiography in all patients and after the {sup 90}Y-infusion by SPECT–CT in 15 of 17 patients. In the 15 assessable patients, the response rate in their 17 lesions was 3 CR, 8 PR, and 6 SD. Dosimetric and toxicity data, as well tumour response rate, were comparable with the 83 patients with regular vasculature.ConclusionsAll embolization procedures were performed successfully with no complications, and the flow redistribution was obtained in all cases. Results in term of toxicity, median dose administered, and radiological response were comparable with standard radioembolizations. Our findings confirmed the intratumoral flow redistribution after embolizing the accessory arteries, which makes it possible to treat the tumour through its single main feeding artery.« less
Del Giudice, C; Pellerin, O; Nouri Neville, M; Amouyal, G; Fitton, I; Leré-Déan, C; Sapoval, M
2018-03-01
To compare outcomes of percutaneous robot-assisted uterine fibroid embolization (UFE) using two different endovascular robotic catheters. Twenty-one patients with a symptomatic uterine fibroid were prospectively enrolled in a single-center study to be treated with a percutaneous robot-assisted embolization using the Magellan system. Fourteen patients were treated using a first generation steerable robotic catheter, version 1.0 (group 1), and seven were treated using the new version 1.1 (group 2). Demographic, pathologic, and procedural variables were recorded. Dose Area Product (DAP) and physician equivalent doses were registered for each procedure. Procedural related complications and clinical midterm outcomes were also evaluated. Successful robot-assisted UFE was obtained in eight patients (57.1%) in group 1 and 7 patients (100%) in group 2 (p = 0.01). A successful robot-assisted catheterization of the internal iliac artery anterior branch was performed in all patients of both groups. Median selective target vessel catheterization time was 21.0 ± 12.8 vs 13.4 ± 7 min (p = 0.04) and total fluoroscopy time was 30.3 ± 11.2 vs 19.3 ± 5.9 min, respectively, in group 1 and 2. Mean DAP decreased from 18472.6 ± 15622 to 5469.1 ± 4461.0 cGy·cm 2 (p = 0.04). All patients obtained a symptoms relief at 6 months follow-up. Robot-assisted uterine fibroid embolization is safe and effective. New version of steerable robotic catheter allows performing a faster procedure without related adverse events compared to old version.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Carnevale, Francisco Cesar, E-mail: francisco.carnevale@criep.com.br; Moreira, Airton Mota; Harward, Sardis Honoria
PurposeTo compare recurrence of lower urinary tract symptoms (LUTS) recurrence at 12 months following original prostate artery embolization (oPAE) or “proximal embolization first, then embolize distal” (PErFecTED) PAE for benign prostatic hyperplasia (BPH).Materials and Methods105 consecutive patients older than 45 years, with prostate size greater than 30 cm{sup 3}, International Prostate Symptom Score (IPSS) ≥ 8, quality of life (QoL) index ≥ 3, and refractory status or intolerance of medical management were prospectively enrolled between June 2008 and August 2013. The study was IRB-approved, and all patients provided informed consent. Patients underwent oPAE or PErFecTED PAE and were followed for at least 12 months. Technical success was definedmore » as bilateral embolization and clinical success (non-recurrence) was defined as removal of the Foley catheter in patients with urinary retention, IPSS < 8 and QoL index < 3 at 12 months of follow-up. Nonparametric statistics were used to compare the study groups due to the size of the study population and distributions of clinical data.Results97 patients had 12-month data and were categorized as oPAE without recurrence (n = 46), oPAE with recurrence (n = 13), PErFecTED without recurrence (n = 36), or PErFecTED with recurrence (n = 2). Recurrence was significantly more common in oPAE patients (χ{sup 2}, p = 0.026). Unilateral embolization was significantly associated with recurrence among patients who underwent oPAE (χ{sup 2}, p = 0.032).ConclusionsBoth oPAE and PErFecTED PAE are safe and effective methods for treatment of LUTS, but PErFecTED PAE is associated with a significantly lower rate of symptom recurrence.« less
Do, Richard K.; Gonen, Mithat; Covey, Anne M.; Getrajdman, George I.; Sofocleous, Constantinos T.; Jarnagin, William R.; D’Angelica, Michael I.; Allen, Peter J.; Erinjeri, Joseph P.; Brody, Lynn A.; O’Neill, Gerald P.; Johnson, Kristian N.; Garcia, Alessandra R.; Beattie, Christopher; Zhao, Binsheng; Solomon, Stephen B.; Schwartz, Lawrence H.; DeMatteo, Ronald; Abou-Alfa, Ghassan K.
2016-01-01
Purpose Transarterial chemoembolization is accepted therapy for hepatocellular carcinoma (HCC). No randomized trial has demonstrated superiority of chemoembolization compared with embolization, and the role of chemotherapy remains unclear. This randomized trial compares the outcome of embolization using microspheres alone with chemoembolization using doxorubicin-eluting microspheres. Materials and Methods At a single tertiary referral center, patients with HCC were randomly assigned to embolization with microspheres alone (Bead Block [BB]) or loaded with doxorubicin 150 mg (LC Bead [LCB]). Random assignment was stratified by number of embolizations to complete treatment, and assignments were generated by permuted blocks in the institutional database. The primary end point was response according to RECIST 1.0 (Response Evaluation Criteria in Solid Tumors) using multiphase computed tomography 2 to 3 weeks post-treatment and then at quarterly intervals, with the reviewer blinded to treatment allocation. Secondary objectives included safety and tolerability, time to progression, progression-free survival, and overall survival. This trial is currently closed to accrual. Results Between December 2007 and April 2012, 101 patients were randomly assigned: 51 to BB and 50 to LCB. Demographics were comparable: median age, 67 years; 77% male; and 22% Barcelona Clinic Liver Cancer stage A and 78% stage B or C. Adverse events occurred with similar frequency in both groups: BB, 19 of 51 patients (38%); LCB, 20 of 50 patients (40%; P = .48), with no difference in RECIST response: BB, 5.9% versus LCB, 6.0% (difference, −0.1%; 95% CI, −9% to 9%). Median PFS was 6.2 versus 2.8 months (hazard ratio, 1.36; 95% CI, 0.91 to 2.05; P = .11), and overall survival, 19.6 versus 20.8 months (hazard ratio, 1.11; 95% CI, 0.71 to 1.76; P = .64) for BB and LCB, respectively. Conclusion There was no apparent difference between the treatment arms. These results challenge the use of doxorubicin-eluting beads for chemoembolization of HCC. PMID:26834067
Contemporary Endovascular Embolotherapy for Meningioma
Dubel, Gregory J.; Ahn, Sun Ho; Soares, Gregory M.
2013-01-01
Preoperative endovascular tumor embolization has been used for 40 years. Meningiomas are the most common benign intracranial tumor in which preoperative embolization has been most extensively described in the literature. Advocates of embolization report that it reduces operative blood-loss, and softens the tumor, thus making surgery safer and easier. Opponents suggest that it adds additional risk and cost for patients without controlled studies showing conclusive benefit. The literature suggests a 3 to 6% neurological complication rate related to embolization. The combined external and internal carotid artery blood supply and complex anastomoses of the meninges can make embolization challenging. Positive outcomes require thorough knowledge of the pertinent vascular anatomy, familiarity with the neurovascular equipment and embolics, and meticulous technique. There remains debate on several aspects of embolization, including tumors most appropriate for embolization, embolic agent of choice, ideal size of embolic, and the choice of vessel(s) to embolize. This detailed review of pertinent vascular anatomy, embolization technique, results, and complications should allow practitioners to maximize treatment outcomes in this setting. PMID:24436548
Water-Borne Endovascular Embolics Inspired by the Undersea Adhesive of Marine Sandcastle Worms.
Jones, Joshua P; Sima, Monika; O'Hara, Ryan G; Stewart, Russell J
2016-04-06
Transcatheter embolization is used to treat vascular malformations and defects, to control bleeding, and to selectively block blood supply to tissues. Liquid embolics are used for small vessel embolization that require distal penetration. Current liquid embolic agents have serious drawbacks, mostly centered around poor handling characteristics and toxicity. In this work, a water-borne in situ setting liquid embolic agent is described that is based on electrostatically condensed, oppositely charged polyelectrolytes-complex coacervates. At high ionic strengths, the embolic coacervates are injectable fluids that can be delivered through long narrow microcatheters. At physiological ionic strength, the embolic coacervates transition into a nonflowing solid morphology. Transcatheter embolization of rabbit renal arteries demonstrated capillary level penetration, homogeneous occlusion, and 100% devascularization of the kidney, without the embolic crossing into venous circulation. The benign water-borne composition and setting mechanism avoids many of the problems of current liquid embolics, and provides precise temporal and spatial control during endovascular embolization. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Vollherbst, D F; Sommer, C M; Ulfert, C; Pfaff, J; Bendszus, M; Möhlenbruch, M A
2017-07-01
Embolization plays a key role in the treatment of arteriovenous malformations. The aim of this study was to evaluate an established (Onyx) and a novel (precipitating hydrophobic injectable liquid [PHIL]) liquid embolic agent in an in vitro AVM model. An AVM model was integrated into a circuit system. The artificial nidus (subdivided into 28 honeycomb-like sections) was embolized with Onyx 18 (group Onyx; n = 8) or PHIL 25 (group PHIL; n = 8) with different pause times between the injections (30 and 60 seconds, n = 4 per study group) by using a 1.3F microcatheter. Procedure times, number of injections, embolization success (defined as the number of filled sections of the artificial nidus), volume of embolic agent, and frequency and extent of reflux and draining vein embolization were assessed. Embolization success was comparable between Onyx and PHIL. Shorter pause times resulted in a significantly higher embolization success for PHIL (median embolization score, 28 versus 18; P = .011). Compared with Onyx, lower volumes of PHIL were required for the same extent of embolization (median volume per section of the artificial nidus, 15.5 versus 3.6 μL; P < .001). While the embolization success was comparable for Onyx and PHIL, pause time had a considerable effect on the embolization success in an in vitro AVM model. Compared with Onyx, lower volumes of PHIL were required for the same extent of embolization. © 2017 by American Journal of Neuroradiology.
Belenky, Alexander; Haddad, Menashe; Idov, Igor; Knizhnik, Michael; Litvin, Sergey; Bachar, Gil N; Atar, Eli
2009-09-01
The purpose of this study was to report our experience in elongating short distal necks of descending thoracic aortic aneurysms (DTAAs) by coil embolization of the celiac trunk prior to endovascular aneurysm repair (EVAR). During 6 years seven patients (five men and two women; mean age, 74) who had DTAAs with short distal necks unsuitable for conventional EVAR, and well patent superior and inferior mesenteric arteries based on CT, were treated in one session with EVAR after the celiac trunk was coil embolized to elongate the neck. All patients were followed by CT every 3 months in the first year and every 6 months thereafter. Technical success was achieved in all patients, and no early or late ischemic complications were noted. No procedural complications occurred and good aneurysm sealing was obtained in all patients. Three endoleaks were identified after 3 months (one patient) and 6 months (two patients); all were treated successfully with insertion of an additional stent-graft. In patients with DTAAs who are candidates for EVAR but have short aneurysm distal necks, celiac trunk embolization -- only if the superior and inferior mesenteric arteries are patent -- is a good and safe way to elongate the neck and enable EVAR.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Belenky, Alexander; Haddad, Menashe; Idov, Igor
2009-09-15
The purpose of this study was to report our experience in elongating short distal necks of descending thoracic aortic aneurysms (DTAAs) by coil embolization of the celiac trunk prior to endovascular aneurysm repair (EVAR). During 6 years seven patients (five men and two women; mean age, 74) who had DTAAs with short distal necks unsuitable for conventional EVAR, and well patent superior and inferior mesenteric arteries based on CT, were treated in one session with EVAR after the celiac trunk was coil embolized to elongate the neck. All patients were followed by CT every 3 months in the first yearmore » and every 6 months thereafter. Technical success was achieved in all patients, and no early or late ischemic complications were noted. No procedural complications occurred and good aneurysm sealing was obtained in all patients. Three endoleaks were identified after 3 months (one patient) and 6 months (two patients); all were treated successfully with insertion of an additional stent-graft. In patients with DTAAs who are candidates for EVAR but have short aneurysm distal necks, celiac trunk embolization-only if the superior and inferior mesenteric arteries are patent-is a good and safe way to elongate the neck and enable EVAR.« less
Chen, Zhenyu; Li, Ju; Shen, Jian; Jin, Jiaxi; Zhang, Wei; Zhong, Wan
2016-12-01
To evaluate direct puncture embolization of the internal iliac artery with hemostatic gelatin sponge particles to treat pernicious placenta previa coexisting with placenta accreta during cesarean delivery. A retrospective study was conducted of data from women with pernicious placenta previa and placenta accreta who underwent direct puncture embolization of the internal iliac artery during cesarean delivery at a center in China between September 1, 2013, and February 28, 2015. Information regarding surgical procedures, operative data, and outcomes during hospitalization were obtained from medical records. The procedure was successful in all 16 cases included. Mean operative time was 78 minutes (range 65-90) and mean estimated blood loss was 1550 mL (range 1000-2500). Complications such as fever, buttock pain, or acute limb ischemia were not observed. The procedure was performed after partial cystectomy for two patients with bladder invasion. Postoperative Doppler imaging indicated uterine recovery and normalized uterine blood flow in all patients. Direct puncture embolization of the internal iliac artery during cesarean delivery was a safe, effective, simple, and rapid method to control hemorrhage among women with pernicious placenta previa and placenta accreta. Copyright © 2016 International Federation of Gynecology and Obstetrics. Published by Elsevier Ireland Ltd. All rights reserved.
Directional dual-tree complex wavelet packet transforms for processing quadrature signals.
Serbes, Gorkem; Gulcur, Halil Ozcan; Aydin, Nizamettin
2016-03-01
Quadrature signals containing in-phase and quadrature-phase components are used in many signal processing applications in every field of science and engineering. Specifically, Doppler ultrasound systems used to evaluate cardiovascular disorders noninvasively also result in quadrature format signals. In order to obtain directional blood flow information, the quadrature outputs have to be preprocessed using methods such as asymmetrical and symmetrical phasing filter techniques. These resultant directional signals can be employed in order to detect asymptomatic embolic signals caused by small emboli, which are indicators of a possible future stroke, in the cerebral circulation. Various transform-based methods such as Fourier and wavelet were frequently used in processing embolic signals. However, most of the times, the Fourier and discrete wavelet transforms are not appropriate for the analysis of embolic signals due to their non-stationary time-frequency behavior. Alternatively, discrete wavelet packet transform can perform an adaptive decomposition of the time-frequency axis. In this study, directional discrete wavelet packet transforms, which have the ability to map directional information while processing quadrature signals and have less computational complexity than the existing wavelet packet-based methods, are introduced. The performances of proposed methods are examined in detail by using single-frequency, synthetic narrow-band, and embolic quadrature signals.
Successful embolization of iatrogenic ruptured coronary artery using Onyx: a new technique.
Asouhidou, I; Katsaridis, V
2014-12-01
Iatrogenic perforation of coronary artery is rare during percutaneous coronary intervention (PCI); however the complications are life-threatening. Patients in this clinical setting may be treated either by stent placement, closure of the perforation with fibrin glue or coils, or with emergency bypass surgery. Onyx, a new material that has been used successfully in cerebral arteries, represents a new and safe alternative. The advantage of Onyx is that it is easily injected through a microcatheter and it allows for a longer injection time having also the ability to reach difficult anatomical locations. We present the first case of successful embolization of a right coronary artery perforation during coronary angiography using Onyx.
Senturk, Cagin
2015-12-01
We report a case where migrated Onyx could be removed safely with a mechanical thrombectomy device after withdrawal of the damaged microcatheter. A microcatheter was retained in the superior cerebellar artery with attached Onyx fragments on its tip during embolization of a bled cerebellar AVM. During retrieval maneuvers microcatheter shaft was ruptured and Onyx fragments were released into the vertebrobasilar system causing occlusion. Finally, Onyx fragment on tip of the microcatheter could be detached with dimethyl sulfoxide injection and the microcatheter could be withdrawn. A Merci retriever device (Concentric Medical, Mountain View, CA, USA) was successfully used to retrieve most of the dislodged Onyx material and recanalize the vertebrobasilar circulation.
Embolectomy of a Bird's Nest Vena Caval Filter.
Chitwood, W R; Chiang, K S; Williams, J M; Zeri, R S; Semer, D A
1994-12-01
In this case report we describe a successful embolectomy of a partially migrated Bird's Nest Caval Filter with attached embolic material. We used transesophageal echocardiography to guide the surgical approach. The patient recovered uneventfully from both the embolectomy and the subsequent pelvic operation.
Embolization of Brain Aneurysms and Fistulas
... Resources Professions Site Index A-Z Embolization of Brain Aneurysms and Arteriovenous Malformations/Fistulas Embolization of brain ... Brain Aneurysms and Fistulas? What is Embolization of Brain Aneurysms and Fistulas? Embolization of brain aneurysms and ...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Arrayeh, Elnasif; Fidelman, Nicholas, E-mail: nicholas.fidelman@ucsf.edu; Gordon, Roy L.
Purpose: To determine whether transcatheter arterial embolization performed in the setting of active gastric or duodenal nonvariceal hemorrhage is efficacious when the bleeding source cannot be identified angiographically. Methods: Records of 115 adult patients who underwent visceral angiography for endoscopically documented gastric (50 patients) or duodenal (65 patients) nonvariceal hemorrhage were retrospectively reviewed. Patients were subdivided into three groups according to whether angiographic evidence of arterial hemorrhage was present and whether embolization was performed (group 1 = no abnormality, no embolization; group 2 = no abnormality, embolization performed [empiric embolization]; and group 3 = abnormality present, embolization performed). Thirty-day ratesmore » and duration of primary hemostasis and survival were compared.ResultsFor patients with gastric sources of hemorrhage, the rate of primary hemostasis at 30 days after embolization was greater when embolization was performed in the setting of a documented angiographic abnormality than when empiric embolization was performed (67% vs. 42%). The rate of primary hemostasis at 30 days after angiography was greater for patients with duodenal bleeding who either underwent empiric embolization (60%) or embolization in the setting of angiographically documented arterial hemorrhage (58%) compared with patients who only underwent diagnostic angiogram (33%). Patients with duodenal hemorrhage who underwent embolization were less likely to require additional invasive procedures to control rebleeding (p = 0.006). Conclusion: Empiric arterial embolization may be advantageous in patients with a duodenal source of hemorrhage but not in patients with gastric hemorrhage.« less
The Impact of Chemoembolization Endpoints on Survival in Hepatocellular Carcinoma Patients
Jin, Brian; Wang, Dingxin; Lewandowski, Robert J.; Riaz, Ahsun; Ryu, Robert K.; Sato, Kent T.; Larson, Andrew C.; Salem, Riad; Omary, Reed A.
2010-01-01
OBJECTIVE To investigate the relationship between angiographic embolic endpoints of transarterial chemoembolization (TACE) and survival in patients with hepatocellular carcinoma (HCC). MATERIALS AND METHODS This study retrospectively assessed 105 patients with surgically unresectable HCC who underwent TACE. Patients were classified according to a previously established subjective angiographic chemoembolization endpoint (SACE) scale. Only one patient was classified as SACE level 1 and thus excluded from all subsequent analysis. Survival was evaluated with Kaplan-Meier analysis. Multivariate analysis with Cox’s proportional hazard regression model was used to determine independent prognostic risk factors of survival. RESULTS Overall median survival was 21.1 months (95% confidence interval [CI], 15.9–26.4). Patients embolized to SACE levels 2 and 3 were aggregated and had a significantly higher median survival (25.6 months; 95% CI, 16.2–35.0) than patients embolized to SACE level 4 (17.1 months; 95% CI, 13.3–20.9) (p = 0.035). Multivariate analysis indicated that SACE level 4 (Hazard ratio [HR], 2.49; 95% CI, 1.41–4.42; p = 0.002), European Cooperative Oncology Group performance status > 0 (HR, 1.97; 95% CI, 1.15–3.37; p = 0.013), American Joint Committee on Cancer stage 3 or 4 (HR, 2.42; 95% CI, 1.27–4.60; p = 0.007), and Child-Pugh class B (HR, 1.94; 95% CI, 1.09–3.46; p = 0.025) were all independent negative prognostic indicators of survival. CONCLUSION Embolization to an intermediate, sub-stasis endpoint (SACE levels 2 and 3) during TACE improves survival compared to embolization to a higher, stasis endpoint (SACE level 4). Interventional oncologists should consider targeting these intermediate, sub-stasis angiographic endpoints during TACE. PMID:21427346
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ghelfi, Julien, E-mail: JGhelfi@chu-grenoble.fr; Brichon, Pierre-Yves, E-mail: PYBrichon@chu-grenoble.fr; Frandon, Julien, E-mail: Julien.frandon@chu-nimes.fr
PurposeSurgical esophagectomy is the gold standard treatment of early-stage esophageal cancer. The procedure is complicated with significant morbidity; the most severe complication being the anastomotic leakage. Anastomotic fistulas are reported in 5–25% of cases and are mainly due to gastric transplant ischemia. Here, we report our experience of ischemic pre-conditioning using preoperative arterial embolization (PreopAE) before esophagectomy.Materials and MethodsThe medical records of all patients who underwent oncologic esophagectomy from 2008 to 2015 were retrospectively reviewed. Patients were divided into two groups: patients who received PreopAE, and a control group of patients who did not benefit from ischemic pre-conditioning. The targetmore » arteries selected for PreopAE were the splenic artery, left gastric artery, and right gastric artery. Evaluation of the results was based on anastomotic leakage, postoperative mortality, technical success of PreopAE, and complications related to the embolization procedure.ResultsForty-six patients underwent oncologic esophagectomy with PreopAE and 13 patients did not receive ischemic conditioning before surgery. Thirty-eight PreopAE were successfully performed (83%), but right gastric artery embolization failed for 8 patients. Anastomotic leakage occurred in 6 PreopAE patients (13%) and in 6 patients (46%) in the control group (p = 0.02). The mortality rate was 2% in the PreopAE group and 23% in the control group (p = 0.03). Eighteen patients suffered from partial splenic infarction after PreopAE, all treated conservatively.ConclusionPreoperative ischemic conditioning by arterial embolization before oncologic esophagectomy seems to be effective in preventing anastomotic leakage.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wohlgemuth, Walter A., E-mail: walter.wohlgemuth@ukr.de; Müller-Wille, René, E-mail: Rene.Mueller-Wille@ukr.de; Teusch, Veronika I., E-mail: Veronika.Teusch@gmx.de
2015-06-15
PurposeTo evaluate the efficacy and safety of a novel retrograde transvenous embolization technique of peripheral arteriovenous malformations (AVMs) using Onyx.Materials and MethodsWe conducted a retrospective analysis of all patients who underwent transvenous retrograde Onyx embolization of peripheral AVMs with dominant venous outflow over a 29-month period. The embolization is aimed at retrograde filling of the nidus after building a solid plug in the dominant venous outflow (push-through). Classification, clinical signs, technical aspects, clinical and technical success rates, and complications were recorded. Short-term outcome was assessed.Results11 Symptomatic patients (8 female; mean age 31.4 years) were treated at our Vascular Anomalies Center withmore » this method between January 2012 and May 2014. The AVMs were located on the upper extremity (n = 3), pelvis (n = 2), buttock (n = 2), and lower extremity (n = 4). Retrograde embolization was successfully carried out after preparatory transarterial-flow reduction in eight cases (73 %) and venous-flow reduction with Amplatzer Vascular Plugs in four cases (36 %). Complete devascularization (n = 10; 91 %) or 95 % devascularization (n = 1; 9 %) led to complete resolution (n = 8; 73 %) or improvement of clinical symptoms (n = 3; 27 %). One minor complication occurred (pain and swelling). During a mean follow-up time of 8 months, one clinically asymptomatic recurrence of AVM was detected.ConclusionInitial results suggest that retrograde transvenous Onyx embolization of peripheral AVMs with dominant venous outflow is a safe and effective novel technique with a low complication rate.« less
Gasparovic, Hrvoje; Borojevic, Marko; Malojcic, Branko; Gasparovic, Kristina; Biocina, Bojan
2013-10-01
Aortic manipulation releases embolic material, thereby enhancing the probability of adverse neurologic outcomes following coronary artery bypass grafting (CABG). We prospectively evaluated 59 patients undergoing CABG. Patients in the single (SC, n = 37) and multiple clamp (MC, n = 22) groups were comparable in relation to age and operative risk (p > 0.05). Neurocognitive evaluation consisted of the Auditory Verbal Learning Test (AVLT), Color Trails Test A, the Grooved Pegboard test and the Mini-Mental State Examination. Data acquisition was performed preoperatively, early postoperatively and at the 4-month follow-up. Intraoperative transcranial Doppler (TCD) monitoring was used to quantify the embolic load in relation to different aortic clamping strategies. Preoperative neurocognitive results were similar between the groups (p > 0.05). The incidence of postoperative delirium was greater in the MC group but this failed to reach statistical significance (23% vs 8%, p = 0.14). SC patients had fewer embolization signals (270 ± 181 vs 465 ± 160, p < 0.0001). Early postoperative neurocognitive results were depressed in comparison to preoperative values in both groups (p < 0.05 for multiple comparisons). The magnitude of this cognitive depression was greater in the MC group (p < 0.05 for multiple comparisons). Preoperative levels of neurocognition were restored at follow-up in the SC group in all tests except the AVLT. A trend towards improvements in neurocognitive performances at follow-up was also observed in the MC group. Residual attention, motor skill and memory deficits were, however, documented with multiple tests. In conclusion, the embolic burden was significantly lower in the SC group. This TCD imaging outcome translated into fewer early cognition deficits and superior late restoration of function.
A New Soluble Gelatin Sponge for Transcatheter Hepatic Arterial Embolization
DOE Office of Scientific and Technical Information (OSTI.GOV)
Takasaka, Isao; Kawai, Nobuyuki; Sato, Morio, E-mail: morisato@mail.wakayama-med.ac.jp
2010-12-15
To prepare a soluble gelatin sponge (GS) and to explore the GS particles (GSPs) that inhibit development of collateral pathways when transcatheter hepatic arterial embolization is performed. The approval of the Institutional Committee on Research Animal Care of our institution was obtained. By means of 50 and 100 kDa of regenerative medicine-gelatin (RM-G), RM-G sponges were prepared by freeze-drying and heating to temperatures of 110-150{sup o}C for cross-linkage. The soluble times of RM-GSPs were measured in vitro. Eight swine for transcatheter hepatic arterial embolization were assigned into two groups: six received 135{sup o}C/50RM-GSPs, 125{sup o}C/100RM-GSPs, and 138{sup o}C/50RM-GSPs, with solublemore » time of 48 h or more in vitro; two swine received Gelpart GSPs (G-GSPs) with insoluble time of 14 days as a control. Transarterial chemoembolization was performed on two branches of the hepatic artery per swine. RM-GSPs heated at temperatures of 110-138{sup o}C were soluble. Mean soluble times of the RM-GSPs increased with higher temperature. Hepatic branches embolized with G-GSP remained occluded after 6 days, and development of collateral pathways was observed after 3 days. Hepatic branches embolized with 135{sup o}C/50RM-GSP and 125{sup o}C/100RM-GSP remained occluded for 4 h, and recanalization was observed after 1 day. Hepatic branches embolized with 138{sup o}C/50RM-GS remained occluded for 1 day, and recanalization was observed after 2 days with no development of collateral pathways. In RM-GSs with various soluble times that were prepared by modulating the heating temperature, 138{sup o}C/50RM-GSP was the soluble GSP with the longest occlusion time without inducing development of collateral pathways.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gonçalves, Octavio Meneghelli, E-mail: octaviogalvao@hotmail.com; Carnevale, Francisco Cesar, E-mail: francisco.carnevale@criep.com.br; Moreira, Airton Mota, E-mail: motamoreira@gmail.com
PurposeThe purpose of the study was to compare safety and efficacy outcomes following prostate artery embolization (PAE) for the treatment of lower urinary tract symptoms (LUTS) due to benign prostatic hyperplasia (BPH) with 100–300 versus 300–500 μm tris-acryl gelatin microspheres.Materials and MethodsPatients were prospectively treated between August 2011 and June 2013 to receive PAE with 100–300 μm (group A) or 300–500 μm (group B) tris-acryl gelatin microspheres. Patients were followed for a minimum of 12 months and were assessed for changes in International Prostate Symptom Score (IPSS), quality of life (QoL) index, prostate volume determined by magnetic resonance imaging, serum prostate specific antigen (PSA),more » and maximum urine flow rate (Q{sub max}), as well as any treatment-related adverse events.ResultsFifteen patients were included in each group, and PAE was technically successful in all cases. Both groups experienced significant improvement in mean IPSS, QoL, prostate volume, PSA, and Q{sub max} (p < 0.05 for all). The differences observed between the two groups included a marginally insignificant more adverse events (p = 0.066) and greater mean serum PSA reduction at 3 months of follow-up (p = 0.056) in group A.ConclusionsBoth 100–300 and 300–500 μm microspheres are safe and effective embolic agents for PAE to treat LUTS-related to BPH. Although functional and imaging outcomes did not differ significantly following use of the two embolic sizes, the greater incidence of adverse events with 100–300 μm microspheres suggests that 300–500 μm embolic materials may be more appropriate.« less
Cement pulmonary embolism after vertebroplasty.
Sifuentes Giraldo, Walter Alberto; Lamúa Riazuelo, José Ramón; Gallego Rivera, José Ignacio; Vázquez Díaz, Mónica
2013-01-01
In recent years, the use of vertebral cementing techniques for vertebroplasty and kyphoplasty has spread for the treatment of pain associated with osteoporotic vertebral compression fractures. This is also associated with the increased incidence of complications related with these procedures, the most frequent being originated by leakage of cementation material. Cement can escape into the vertebral venous system and reach the pulmonary circulation through the azygous system and cava vein, producing a cement embolism. This is a frequent complication, occurring in up to 26% of patients undergoing vertebroplasty but, since most patients have no clinical or hemodynamical repercussion, this event usually goes unnoticed. However, some serious, and even fatal cases, have been reported. We report the case of a 74-year-old male patient who underwent vertebroplasty for persistent pain associated with osteoporotic L3 vertebral fracture and who developed a cement leak into the cava vein and right pulmonary artery during the procedure. Although he developed a pulmonary cement embolism, the patient remained asymptomatic and did not present complications during follow-up. Copyright © 2012 Elsevier España, S.L. All rights reserved.
Analyzing fat embolism syndrome in trauma patients at AIIMS Apex Trauma Center, New Delhi, India
Gupta, Babita; D’souza, Nita; Sawhney, Chhavi; Farooque, Kamran; Kumar, Ajeet; Agrawal, Pramendra; Misra, M C
2011-01-01
Background: Fat embolism syndrome (FES) is a constellation of symptoms and signs subsequent to orthopedic trauma. Materials and Methods: The clinical profile of FES in the trauma population was studied over 2 years and 8 months. Results: The incidence of FES among all patients with long bone and pelvic fractures was 0.7% (12). The mean injury severity score was 10.37 (SD 1.69) (range 9-14). The diagnosis of FES was made by clinical and laboratory criteria. Hypoxia was the commonest presentation (92%). The average days of onset of symptoms were 3.5 (SD1.29) days. Management included ventilator support in 75%, average ventilator days being 7.8 (SD 4.08) days. The average ICU stay and hospital stay were 9.1 days and 29.7 days, respectively. A mortality of 8.3% (1) was observed. Conclusion: Fat embolism remains a diagnosis of exclusion and is a clinical dilemma. Clinically apparent FES is unusual and needs high index of suspicion, especially in long bone and pelvic fractures. PMID:21887021
Phillips, Y Y
1986-12-01
Injury from explosion may be due to the direct cussive effect of the blast wave (primary), being struck by material propelled by the blast (secondary), to whole-body displacement and impact (tertiary), or to miscellaneous effects from burns, toxic acids, and so on. Severe primary blast injury is most likely to be seen in military operations but can occur in civilian industrial accidents or terrorist actions. Damage is seen almost exclusively in air-containing organs--the lungs, the gastrointestinal tract, and the auditory system. Pulmonary injury is characterized by pneumothorax, parenchymal hemorrhage, and alveolar rupture. The last is responsible for the arterial air embolism that is the principle cause of early mortality. Treatment for blast injury is similar to that for blunt trauma. The sequalae of air embolization to the cerebral or coronary circulation may be altered by immediate hyperbaric therapy. Use of positive pressure ventilatory systems should be closely monitored as they may increase the risk of air embolism in pneumothorax. Morbidity and mortality may be increased by strenuous exertion after injury and by the wearing of a cloth ballistic vest at the time of the blast.
Pulmonary embolism detection using localized vessel-based features in dual energy CT
NASA Astrophysics Data System (ADS)
Dicente Cid, Yashin; Depeursinge, Adrien; Foncubierta Rodríguez, Antonio; Platon, Alexandra; Poletti, Pierre-Alexandre; Müller, Henning
2015-03-01
Pulmonary embolism (PE) affects up to 600,000 patients and contributes to at least 100,000 deaths every year in the United States alone. Diagnosis of PE can be difficult as most symptoms are unspecific and early diagnosis is essential for successful treatment. Computed Tomography (CT) images can show morphological anomalies that suggest the existence of PE. Various image-based procedures have been proposed for improving computer-aided diagnosis of PE. We propose a novel method for detecting PE based on localized vessel-based features computed in Dual Energy CT (DECT) images. DECT provides 4D data indexed by the three spatial coordinates and the energy level. The proposed features encode the variation of the Hounsfield Units across the different levels and the CT attenuation related to the amount of iodine contrast in each vessel. A local classification of the vessels is obtained through the classification of these features. Moreover, the localization of the vessel in the lung provides better comparison between patients. Results show that the simple features designed are able to classify pulmonary embolism patients with an AUC (area under the receiver operating curve) of 0.71 on a lobe basis. Prior segmentation of the lung lobes is not necessary because an automatic atlas-based segmentation obtains similar AUC levels (0.65) for the same dataset. The automatic atlas reaches 0.80 AUC in a larger dataset with more control cases.
George, Jacob; George, Reeba; Dixit, R.; Gupta, R. C.; Gupta, N.
2013-01-01
Fat embolism syndrome is an often overlooked cause of breathlessness in trauma wards. Presenting in a wide range of clinical signs of varying severity, fat embolism is usually diagnosed by a physician who keeps a high degree of suspicion. The clinical background, chronology of symptoms and corroborative laboratory findings are instrumental in a diagnosis of fat embolism syndrome. There are a few diagnostic criteria which are helpful in making a diagnosis of fat embolism syndrome. Management is mainly prevention of fat embolism syndrome, and organ supportive care. Except in fulminant fat embolism syndrome, the prognosis is usually good. PMID:23661916
Direct Tumor Embolization of Sinonasal Unclassified Spindle Cell Sarcoma with Onyx.
Kansal, Ankit; Srinet, Prateek; Manes, Richard Peter
2016-07-01
To evaluate the use of a new tumor embolization agent, Onyx (Covidien, Dublin, Ireland), for the use of intraoperative embolization of a sinonasal unclassified spindle cell sarcoma. A 45-year-old female patient presented to the rhinology clinic with a nasal mass. A biopsy revealed a highly vascular mass consistent with a sinonasal unclassified spindle cell sarcoma. Secondary to its extensive vascularity, the patient underwent preoperative transarterial embolization (TAE) before definitive resection. Due to complex vascular anatomy including feeding vessels emanating from intracranial circulation, incomplete embolization was achieved. Subsequently, intraoperative embolization with Onyx at the time of resection was performed. Intraoperative Onyx use resulted in almost complete devascularization of the tumor with decreased risk of intracranial embolization. Intraoperative embolization with Onyx after an incomplete TAE can be a safe and effective method of achieving near-total embolization of sinonasal tumors.
Numerical modeling process of embolization arteriovenous malformation
NASA Astrophysics Data System (ADS)
Cherevko, A. A.; Gologush, T. S.; Petrenko, I. A.; Ostapenko, V. V.
2017-10-01
Cerebral arteriovenous malformation is a difficult, dangerous, and most frequently encountered vascular failure of development. It consists of vessels of very small diameter, which perform a discharge of blood from the artery to the vein. In this regard it can be adequately modeled using porous medium. Endovascular embolization of arteriovenous malformation is effective treatment of such pathologies. However, the danger of intraoperative rupture during embolization still exists. The purpose is to model this process and build an optimization algorithm for arteriovenous malformation embolization. To study the different embolization variants, the initial-boundary value problems, describing the process of embolization, were solved numerically by using a new modification of CABARET scheme. The essential moments of embolization process were modeled in our numerical experiments. This approach well reproduces the essential features of discontinuous two-phase flows, arising in the embolization problems. It can be used for further study on the process of embolization.
Wen, Jun; Duan, Chuan-Zhi; Huang, Li-Jing; Zhang, Xin; He, Xu-Ying; Li, Xi-Feng
2015-09-01
Transvenous embolization is the treatment of choice for cavernous sinus dural arteriovenous fistulas (csDAVFs) despite occasional difficulty in transvenous catheterization. We reported our experience in the treatment of csDAVFs by transarterial Onyx embolization in patients who had failed transvenous catheterization. We reviewed the clinical and radiographic records of csDAVFs patients receiving transarterial Onyx embolization after failed transvenous Onyx embolization at our institution over a period of 31 months. Success was defined as complete or near complete occlusion upon angiographic examination. In seven cases, the microcatheter failed to reach the cavernous sinus; in the remaining case, the internal jugular vein was occlusive. Eight sessions of the embolization and catheterization procedures via the arterial routes were conducted. Among them, five cases via the middle meningeal artery and the other three via the accessory meningeal artery. Angiography, immediately after embolization, revealed complete occlusion in seven cases (87.5 %) and partial occlusion in the remaining case. Angiographic follow-up (range, 6-10 months) showed that all patients achieved complete embolization. In cases where transvenous embolization of the cavernous sinus is difficult, transarterial embolization of the fistulas offers a safe and effective alternative.
Hydrogels in endovascular embolization. II. Clinical use of spherical particles.
Horák, D; Svec, F; Kálal, J; Adamyan, A A; Volynskii, Y D; Voronkova, O S; Kokov, L S; Gumargalieva, K Z
1986-11-01
In this study we report the results of clinical experiments, obtained with spherical particles made from poly(2-hydroxyethyl methacrylate) used in the embolization of arteriovenous anastomoses, in the suppression of pulmonary haemorrhage and haemoptysis and in the occlusion of some other arteries. So far we have used these particles in the treatment of 187 patients. It must be stressed that the advantage of spherical particles consists in the simplicity of their introduction into the blood vessel through a catheter, while in the blood vessel itself the particle swells in blood still more, when compared with the particle size in saline. This results in an immediate and permanent haemostatic effect. No revascularization occurs.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Katsumori, Tetsuya, E-mail: katsumo@eurus.dti.ne.jp; Kasahara, Toshiyuki; Oda, Minori
The purpose of this study was to prospectively assess the safety and effectiveness of uterine artery embolization (UAE) using porous gelatin particle (PGP; Gelpart; Asuterasu, Tokyo, Japan) for symptomatic uterine fibroids. Twenty-five consecutive premenopausal women underwent UAE with PGP. The angiographic end point of embolization was near stasis of the ascending uterine artery. Pelvic magnetic resonance imaging (MRI) was obtained before and after the procedure. Complications were assessed. The outcomes of technique, infarction rates of all fibroid tissue after UAE with contrast-enhanced MRI, change in symptoms and quality of life using serial Uterine Fibroid Symptom and Quality of Life (UFS-QOL)more » questionnaires, and additional interventions were evaluated. Bilateral UAE was successfully performed in all patients. Enhanced MRI 1 week after UAE showed that 100% infarction of all fibroid tissue was achieved in 65% (15 of 23) of patients; 90-99% infarction was achieved in 35% (8 of 23) of patients. Mean follow-up was 12 months (range 1-20). Symptom and QOL scores at baseline were 47.2 and 61.7, respectively. Both scores significantly improved to 26.3 (P < 0.001) and 82.4 (P < 0.001) at 4 months and to 20.4 (P < 0.001) and 77.6 (P < 0.001) at 1 year, respectively. No additional gynecologic interventions were performed in any patient. There were no major complications. Minor complications occurred in two patients. UAE using PGP is a safe and effective procedure and shows that outcomes after UAE, as measured with enhanced MRI and UFS-QOL questionnaires, seem comparable with those of UAE using other embolic agents. PGP is a promising embolic agent used for UAE to treat symptomatic uterine fibroids. Further comparative study between PGP and other established embolic agents is required.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dudeck, Oliver, E-mail: oliver.dudeck@med.ovgu.de; Bulla, Karsten; Wieners, Gero
2011-02-15
The purpose of this study was compare embolization of the gastroduodenal artery (GDA) using standard pushable coils with the Interlock detachable coil (IDC), a novel fibered mechanically detachable long microcoil, in patients scheduled for selective internal radiotherapy (SIRT). Fifty patients (31 male and 19 female; median age 66.6 {+-} 8.1 years) were prospectively randomized for embolization using either standard coils or IDCs. Procedure time, radiation dose, number of embolization devices, complications, and durability of vessel occlusion at follow-up angiography were recorded. The procedures differed significantly in time (14:32 {+-} 5:56 min for standard coils vs. 2:13 {+-} 1:04 min formore » IDCs; p < 0.001); radiation dose for coil deployment (2479 {+-} 1237 cGycm Superscript-Two for standard coils vs. 275 {+-} 268 cGycm Superscript-Two for IDCs; p < 0.001); and vessel occlusion (17:18 {+-} 6:39 min for standard coils vs. 11:19 {+-} 7:54 min for IDCs; p = 0.002). A mean of 6.2 {+-} 1.8 coils (n = 27) were used in the standard coil group, and 1.3 {+-} 0.9 coils (p < 0.0001) were used in the IDC group (n = 23) because additional pushable coils were required to achieve GDA occlusion in 4 patients. In 2 patients, the IDC could not be deployed through a Soft-VU catheter. One standard coil dislodged in the hepatic artery and was retrieved. Vessel reperfusion was noted in only 1 patient in the standard coil group. Controlled embolization of the GDA with fibered IDCs was achieved more rapidly than with pushable coils. However, vessel occlusion may not be obtained using a single device only, and the use of sharply angled guiding catheters hampered coil pushability.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Miyayama, Shiro, E-mail: s-miyayama@fukui.saiseikai.or.jp; Yamashiro, Masashi; Okuda, Miho
2009-03-15
This study evaluated the usefulness of cone-beam computed tomography (CBCT) during ultraselective transcatheter arterial chemoembolization (TACE) for hepatocellular carcinomas (HCC) that could not be demonstrated on angiography. Twenty-eight patients with 33 angiographically occult tumors (mean diameter 1.3 {+-} 0.3 cm) were enrolled in the study. The ability of CBCT during arterial portography (CBCTAP), during hepatic arteriography (CBCTHA), and after iodized oil injection (LipCBCT) to detect HCC lesions was retrospectively analyzed. The technical success of TACE was divided into three grades: complete (the embolized area included the entire tumor with at least a 5-mm wide margin), adequate (the embolized area includedmore » the entire tumor but without a 5-mm wide margin in parts), and incomplete (the embolized area did not include the entire tumor) according to computed axial tomographic (CAT) images obtained 1 week after TACE. Local tumor progression was also evaluated. CBCTAP, CBCTHA, and LipCBCT detected HCC lesions in 93.9% (31 of 33), 96.7% (29 of 30), and 100% (29 of 29) of patients, respectively. A single branch was embolized in 28 tumors, and 2 branches were embolized in five tumors. Twenty-seven tumors (81.8%) were classed as complete, and 6 (18.2%) were classed as adequate. None of the tumors were classed as incomplete. Twenty-five tumors (75.8%) had not recurred during 12.0 {+-} 6.2 months. Eight tumors (24.2%), 5 (18.5%) of 27 complete success and 3 (50%) of 6 adequate success, recurred during 10.1 {+-} 6.2 months. CBCT during TACE is useful in detecting and treating small HCC lesions that cannot not be demonstrated on angiography.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pellerin, Olivier, E-mail: olivier.pellerin@egp.aphp.fr; Bats, Anne-Sophie; Primio, Massimiliano Di
To evaluate the efficacy and safety of superselective embolization of the uterine arteries in a postpartum hemorrhage. Between November 2004 and January 2011, a total of 44 consecutive women (median {+-} standard deviation age 34 {+-} 3 years, range 23-41 years) were referred to our institution for postpartum intractable hemorrhage management. All patients were embolized with a microcatheter that was placed deep into the uterine arteries upstream of the cervical arteries. The embolic agent was a mixture of contrast medium and 5 Multiplication-Sign 5 Multiplication-Sign 5 cm pieces of gelfoam (Gelita-Spon) modified into a gelatin emulsion as follows: rapid mixingmore » through a three-way stopcock with two 2.5-ml syringes. A 1-ml syringe was used for injection. One month after embolization, all patients underwent magnetic resonance imaging and clinical examination. Technical and clinical success was obtained in all cases. Thirty-five patients experienced bleeding related to poor retraction of the uterus, 7 patients because of a tear of the cervix and 2 because of a vaginal hematoma. Pre- and postembolization red blood cell transfusions were (mean {+-} standard deviation [SD]) 6 {+-} 1.2 (range 3-8) U and 2 {+-} 0.7 (range 2-4) U, respectively. One-month magnetic resonance imaging follow-up revealed no sign of ischemic myometrium or necrosis, and no instances of uterine rupture and no pelvic vein thrombosis. Incidental findings included two small intramyometrial hematic collections. All uterine arteries were patent via magnetic resonance angiography. Seventeen patients had concomitant fibroids, all of which appeared hypovascular. This technique permits good, safe clinical results with no marked damage to the uterine arteries or the uterus itself.« less
Endovascular treatment for traumatic scalp arteriovenous fistulas: results with Onyx embolization.
Dabus, Guilherme; Pizzolato, Raffaella; Lin, Eugene; Kreusch, Andreas; Linfante, Italo
2014-06-01
Arteriovenous fistulas of the scalp (S-AVFs) are rare lesions and may occur spontaneously or secondary to trauma. The use of Onyx for the treatment of S-AVFs is not well established at this time. We discuss three cases of traumatic S-AVFs treated successfully with Onyx embolization alone or in association with coils. The database of patients treated at the Baptist Cardiac and Vascular Institute, Miami, Florida, was reviewed. All patients with traumatic S-AVFs treated with Onyx were included. Two men and one woman with progressive enlarging pulsatile mass with bruit or tinnitus had angiographic evidence of S-AVF and were treated. In two patients the S-AVFs were secondary to hair transplantation. They were treated with Onyx-18 embolization as the single treatment modality. One patient with S-AVF resulting from temporomandibular joint arthroscopy was treated with coils and subsequent Onyx-34 embolization. In one patient, transarterial microcatheterization and injection of Onyx-18 was performed. In another patient, the intra-arterial approach was prevented by arterial vessel tortuosity. Therefore, access to the fistula was obtained through direct puncture of a large frontal vein; contrast injection confirmed the positioning of the needle within the draining vein of the AVF and Onyx-18 was then injected while the outflow vein was compressed. In the third patient in this series, coils were deployed to allow safer and more controlled injection of Onyx-34. No procedure related complications were noted. Post-embolization angiography demonstrated successful and complete occlusion of the AVF immediately after treatment. Follow-up revealed complete resolution of the symptoms. Our experience in this small series indicates that endovascular treatment of S-AVFs with Onyx is rapid, safe, and highly effective.
Diana, Michele; Pop, Raoul; Beaujeux, Rémy; Dallemagne, Bernard; Halvax, Peter; Schlagowski, Isabel; Liu, Yu-Yin; Diemunsch, Pierre; Geny, Bernard; Lindner, Veronique; Marescaux, Jacques
2015-03-01
Embolization of the left gastric artery (LGA) reduces circulating levels of ghrelin, but might prevent from further obesity surgery, particularly sleeve gastrectomy (SG), since the gastroesophageal junction (GEJ), depending on LGA, would be devascularized. Our aim was to evaluate, in an experimental animal study, an endovascular approach targeting arteries of the gastroepiploic arcade aiming to modulate ghrelin levels and to generate an increased vascular supply of the GEJ to reduce the risks of staple-line leaks after SG. Seven pigs underwent embolization of both left and right gastroepiploic arteries (LGEA and RGEA) using 500-700-μ microspheres (embolization of arterial gastric supply in obesity (EMBARGO)-alpha). A SG was performed in six pigs 3 weeks after EMBARGO-alpha and on eight controls. Capillary lactates were measured at the cardia and pylorus. Five pigs underwent coiling of RGEA and embolization of LGEA using both coils and 100-300-μ microspheres (EMBARGO-beta). Ghrelin levels were assessed before and once per week after both EMBARGOs. Control celiac trunk angiography was performed at 3 weeks (alpha) and 4 weeks (beta). No significant ghrelin reduction was obtained with EMBARGO-alpha at 3 weeks when compared to baseline. Significant ghrelin reduction was found 3 weeks (p = 0.0363) and 4 weeks (p = 0.025) after EMBARGO-beta. Post-EMBARGO-alpha animals presented a significantly lower increase in cardia lactates when compared to controls after SG. Control angiography showed a significantly increased fundic vascular network in 5/6 animals after EMBARGO-alpha and in 5/5 after EMBARGO-beta. EMBARGO is effective to decrease ghrelin production and can enhance the vascular supply of the GEJ, preparing the vascular background for a SG.
Bariatric embolization for suppression of the hunger hormone ghrelin in a porcine model.
Paxton, Ben E; Kim, Charles Y; Alley, Christopher L; Crow, Jennifer H; Balmadrid, Bryan; Keith, Christopher G; Kankotia, Ravi J; Stinnett, Sandra; Arepally, Aravind
2013-02-01
To prospectively test in a porcine model the hypothesis that bariatric embolization with commercially available calibrated microspheres can result in substantial suppression of systemic ghrelin levels and affect weight gain over an 8-week period. The institutional animal care and use committee approved this study. Twelve healthy growing swine (mean weight, 38.4 kg; weight range, 30.3-47.0 kg) were evaluated. Bariatric embolization was performed by infusion of 40-μm calibrated microspheres selectively into the gastric arteries that supply the fundus. Six swine underwent bariatric embolization, while six control animals underwent a sham procedure with saline. Weight and fasting plasma ghrelin and glucose levels were obtained in animals at baseline and at weeks 1-8. Statistical testing for differences in serum ghrelin levels and weight at each time point was performed with the Wilcoxon signed rank test for intragroup differences and the Wilcoxon rank sum test for intergroup differences. The pattern of change in ghrelin levels over time was significantly different between control and experimental animals. Weekly ghrelin levels were measured in control and experimental animals as a change from baseline ghrelin values. Average postprocedure ghrelin values increased by 328.9 pg/dL ± 129.0 (standard deviation) in control animals and decreased by 537.9 pg/dL ± 209.6 in experimental animals (P = .004). The pattern of change in weight over time was significantly different between control and experimental animals. The average postprocedure weight gain in experimental animals was significantly lower than that in control animals (3.6 kg ± 3.8 vs 9.4 kg ± 2.8, respectively; P = .025). Bariatric embolization can significantly suppress ghrelin and significantly affect weight gain. Further study is warranted before this technique can be used routinely in humans.
Al-Sharydah, A M; Al-Abdulwahhab, A H; Abu AlOla, H A
2018-05-03
In patients with a hypercoagulable state, such as patients with pulmonary embolism and/or Budd-Chiari syndrome, the complications from multiple gene mutations are more numerous than those from a single mutation. The authors present a woman with no major prior medical history who presented with pulmonary embolism and Budd-Chiari syndrome; this enigmatic co-occurrence has never been solely reported without underlying aetiology in a patient without prior medical conditions. A 20-year-old female presented to the emergency room complaining of a sudden onset of acute epigastric abdominal pain lasting for approximately 2 h. The patient's liver enzymes were severely elevated. Computed tomography of her abdomen showed thrombosed hepatic veins as well as supra-hepatic and hepatic portions of the inferior vena cava. She was becoming progressively hypotensive despite supplying intravenous fluid. Consequently, the patient received a contrast chest CT, which revealed the presence of acute pulmonary embolism; to confirm the diagnosis of a perfusion abnormality with normal ventilation, a clear radiograph in that region was obtained, denoting a V/Q study mismatch. Many details regarding the enigmatic mechanism behind the appearance of such a thrombotic co-occurrence in our patient are unclear. Since the anticardiolipin antibody IgG and IgM serum levels were normal, blood eosinophil count was persistently normal, and no signs of autoimmune disease were found, the diagnosis of autoimmune disease in the case under discussion is unlikely. Adding pulmonary embolism to the list of complications associated with Budd-Chiari syndrome is highly suggested, regardless of having predisposing condition(s). Copyright © 2018 The Author(s). Published by Elsevier Ltd.. All rights reserved.
Pron, Gaylene; Bennett, John; Common, Andrew; Sniderman, Kenneth; Asch, Murray; Bell, Stuart; Kozak, Roman; Vanderburgh, Leslie; Garvin, Greg; Simons, Martin; Tran, Cuong; Kachura, John
2003-05-01
To document the technical results and spectrum of practice of uterine artery embolization (UAE) for fibroids in the health care setting in Canada. The effects of interventional radiologist's (IR's) experience with UAE on procedure and fluoroscopy time were also investigated. The study involved a multicenter prospective single-arm clinical treatment trial and included the practices of 11 IRs at eight university-affiliated teaching and community hospitals. Vascular access with percutaneous femoral artery approach was followed by transcatheter delivery of polyvinyl alcohol (PVA) particles into uterine arteries with fluoroscopic guidance. Technical success, complications, procedural time, fluoroscopy time, and effects of operator experience were outcomes analyzed. Between November 1998 and November 2000, 570 embolization procedures were performed in 555 patients. UAE was bilaterally successful in 97% (95% CI: 95%-98%). Variant anatomy was the most common reason for failure to embolize bilaterally. The procedural complication rate was 5.3% (95% CI: 3.6%-7.4%). Of the 30 events, three involved major complications (one seizure and two allergic reactions) that resulted in additional care or extended hospital stay. Procedure time and fluoroscopy time averaged 61 minutes (95% CI; 58-63 minutes) and 18.9 minutes (95% CI; 18-19.8) and varied significantly among IRs (P <.001; P <.001). The average 27% reduction in procedure time (20 minutes; P <.001) and 24% reduction in fluoroscopy time (5.1 minutes; P <.001) with increasing UAE experience were significant. A high level of technical success with few complications was obtained with a variety of operators in diverse practice settings. Increased experience in UAE significantly reduced procedure and fluoroscopy time.
Lungren, Matthew P; Lindquester, Will S; Seidel, Frank Glen; Kothary, Nishita; Monroe, Eric J; Shivaram, Giri; Gill, Anne E; Hawkins, Matthew C
2016-12-01
The aim of the study was to describe and assess the technical success and safety of ultrasound-guided liver biopsy with gelatin sponge pledget tract embolization technique in infants <10 kg across 3 tertiary pediatric hospitals. There were 67 pediatric patients weighing <10 kg (36 boys; 31 girls; average age 202 days; average weight 6 kg, range 1.5-9.9 kg) referred for liver biopsy performed with ultrasound guidance and gelatin sponge pledget tract embolization during a 2-year period. Patient history, procedural records, and clinical follow-up documents were retrospectively reviewed. A total of 67 procedures were included. There was 100% technical success rate and all samples obtained provided adequate tissue for histological assessment. Average number of 18 G biopsy passes was 3 (range 1-6). There were no procedure-related deaths. There was 1 complication (1%) in a 5-kg infant who was readmitted 36 hours after biopsy with a fever and fully recovered after antibiotics were administered. Biliary atresia was the most common underlying diagnosis (20%), whereas others included acute rejection (16%) and biliary obstruction (7%). Ultrasound-guided percutaneous liver biopsy with gelatin sponge pledget tract embolization technique in children weighing <10 kg is safe, effective, and use of this technique may lead to a reduction in rates of adverse events reported in other pediatric series.
Aherrera, Jaime Alfonso M.; Abola, Maria Teresa B.; Balabagno, Maria Margarita O.; Abrahan, Lauro L.; Magno, Jose Donato A.; Reganit, Paul Ferdinand M.; Punzalan, Felix Eduardo R.
2016-01-01
Background Cardioembolic events are life-threatening complications of infective endocarditis (IE). The embolic risk French calculator estimates the embolic risk in IE computed on admission. Variables in this tool include age, diabetes, atrial fibrillation, prior embolism, vegetation length, and Staphylococcus aureus on culture. A computed risk of > 7% was considered high in the development of this tool. Knowledge of this risk applied in our local setting is important to guide clinicians in preventing such catastrophic complications. Among patients with IE, we aim to determine the efficacy of the embolic risk French calculator, using a computed score of > 7%, in predicting major embolic events. Methods All adults admitted from 2013 to 2016 with definite IE were included. The risk for embolic events was computed on admission. All were monitored for the duration of admission for the occurrence of the primary outcome (any major embolic event: arterial emboli, intracranial hemorrhage, pulmonary infarcts, or aneurysms). Secondary outcomes were: 1) composite of death and embolic events; and 2) death from any cause. Results Eighty-seven adults with definite IE were included. Majority had a valvular heart disease and preserved ejection fraction (EF). The mitral valve was most commonly involved. Embolic events occurred in 25 (29%). Multivariate analysis identified a high embolic score > 7% (relative risk (RR): 15.12, P < 0.001), vegetation area ≥ 18 mm2 (RR: 6.39, P < 0.01), and a prior embolism (RR: 5.18, P = 0.018) to be independent predictors of embolic events. For the composite of embolic events and death, independent predictors include a high score of > 7% (RR: 13.56, P < 0.001) and a prior embolus (RR: 13.75, P = 0.002). Independent predictors of death were a high score > 7% (RR: 6.20, P = 0.003) and EF ≤ 45% (RR: 9.91, P = 0.004). Conclusion Cardioembolic events are more prevalent in our study compared to previous data. The embolic risk French calculator is a useful tool to estimate and predict risk for embolic events and in-hospital mortality. The risk of developing embolic events should be weighed against the risks of early preventive cardiac surgery, as to institute timely and appropriate management. PMID:28197281
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rayt, H. S., E-mail: hsrayt@hotmail.com; Bown, M. J.; Lambert, K. V.
2008-07-15
Coil embolization of the internal iliac artery (IIA) is used to extend the application of endovascular aneurysm repair (EVAR) in cases of challenging iliac anatomy. Pelvic ischemia is a complication of the technique, but reports vary as to the rate and severity. This study reports our experience with IIA embolization and compares the results to those of other published series. The vascular unit database of the Leicester Royal Infirmary was used to identify patients who had undergone IIA coil embolization prior to EVAR. Data were collected from hospital case notes and by telephone interviews. Thirty-eight patients were identified; 29 ofmore » these were contactable by telephone. A literature search was performed for other studies of IIA embolization and the results were pooled. In this series buttock claudication occurred in 55% (16 of 29 patients) overall: in 52% of unilateral embolizations (11 of 21) and 63% of bilateral embolizations (5 of 8). New erectile dysfunction occurred in 46% (6 of 13 patients) overall: in 38% of unilateral embolizations (3 of 8) and 60% of bilateral embolizations (3 of 5). The literature review identified 18 relevant studies. The results were pooled with our results, to give 634 patients in total. Buttock claudication occurred in 28% overall (178 of 634 patients): in 31% of unilateral embolizations (99 of 322) and 35% of bilateral embolizations (34 of 98) (p = 0.46, Fisher's exact test). New erectile dysfunction occurred in 17% overall (27 of 159 patients): in 17% of unilateral embolizations (16 of 97) and 24% of bilateral embolizations (9 of 38) (p = 0.33). We conclude that buttock claudication and erectile dysfunction are frequent complications of IIA embolization and patients should be counseled accordingly.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mueller-Wille, Rene, E-mail: rene.mueller-wille@ukr.de; Wohlgemuth, Walter A., E-mail: walter.wohlgemuth@ukr.de; Heiss, Peter, E-mail: peter.heiss@ukr.de
2013-10-15
Purpose: To determine the feasibility and efficacy of transarterial endoleak embolization using the liquid embolic agent ethylene vinyl alcohol copolymer (Onyx). Methods: Over a 7-year period eleven patients (6 women, 5 men; mean age 68 years, range 37-83 years) underwent transarterial embolization of a type II endoleak after endovascular aortic aneurysm repair using the liquid embolic agent Onyx. Two patients (18 %) had a simple type II endoleak with only one artery in communication with the aneurysm sac, whereas 9 patients (82 %) had a complex type II endoleak with multiple communicating vessels. We retrospectively analyzed the technical and clinicalmore » success of transarterial type II endoleak embolization with Onyx. Complete embolization of the nidus was defined as technical success. Embolization was considered clinically successful when volume of the aneurysm sac was stable or decreased on follow-up CT scans. Result: Mean follow-up time was 26.0 (range 6-50) months. Clinical success was achieved in 8 of 11 patients (73 %). Transarterial nidus embolization with Onyx was technically successful in 6 of 11 patients (55 %). In three cases the nidus was embolized without direct catheterization from a more distal access through the network of collateral vessels. Conclusion: Onyx is a favorable embolic agent for transarterial endoleak embolization. To achieve the best clinical results, complete occlusion of the nidus is mandatory.« less
Tang, Benqiang; Ji, Tao; Guo, Wei; Tang, Xiaodong; Jin, Long; Dong, Sen; Xie, Lu
2018-06-01
Previous series presented the timing between embolization and surgery in a wide range on the basis of their experience rather than supportive data. And comparative studies were limited to small samples. In addition, there is no study publishing the timing by considering both safety and efficacy of embolization. The aim of this study was to determine the better timing (the same day or the next day) between embolization and surgery for hypervascular spinal tumors by assessing the safety and efficacy of embolization.One hundred twenty-five embolizations with subsequent 120 operations for hypervascular spinal tumors between January 2010 and April 2013 were retrospectively reviewed. The time between embolization and surgery was mainly determined by interventional radiologist schedules and operating room available. Major complications of embolization were documented. The efficacy of embolization was compared between the same day and the next day group.Of the 125 embolizations, there were 4 major complications, all of which occurred on the same day of procedure. Of the 120 operations, 36 cases were operated on the same day of embolization, 74 on the next day, and 10 on the second day. When comparing the efficacy of embolization between the same day and the next day group, intraoperative blood loss (1483 ± 1475 vs 1548 ± 1099 mL, P = .80), intraoperative transfusion requirement (1011 ± 1200 vs 1112 ± 890 mL, P = .62), and postoperative blood loss (1146 ± 933 vs 1031 ± 777 mL, P = .50) were not significantly different.Embolization carries certain risks (4/125, 3.2%) for major complications, which may occur within the time window of 1 day. Two patient groups showed no difference on the efficacy of embolization. Operation should be scheduled on the next day of embolization if possible.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Parthipun, A. A., E-mail: aneeta@hotmail.co.uk; Taylor, J.; Manyonda, I.
The purpose of this study was to determine whether there is a correlation between large uterine fibroid diameter, uterine volume, number of vials of embolic agent used and risk of complications from uterine artery embolisation (UAE). This was a prospective study involving 121 patients undergoing UAE embolisation for symptomatic uterine fibroids at a single institution. Patients were grouped according to diameter of largest fibroid and uterine volume. Results were also stratified according to the number of vials of embolic agent used and rate of complications. No statistical difference in complication rate was demonstrated between the two groups according to diametermore » of the largest fibroid (large fibroids were classified as {>=}10 cm; Fisher's exact test P = 1.00), and no statistical difference in complication rate was demonstrated according to uterine volume (large uterine volume was defined as {>=}750 cm{sup 3}; Fisher's exact test P = 0.70). 84 of the 121 patients had documentation of the number of vials used during the procedure. Patients were divided into two groups, with {>=}4 used defined as a large number of embolic agent. There was no statistical difference between these two groups and no associated increased risk of developing complications. This study showed no increased incidence of complications in women with large-diameter fibroids or uterine volumes as defined. In addition, there was no evidence of increased complications according to quantity of embolic material used. Therefore, UAE should be offered to women with large fibroids and uterine volumes.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Saeed Kilani, Mohammad, E-mail: msaeedkilani@gmail.com, E-mail: mohammadalikilani@yahoo.com; Zehtabi, Fatemeh, E-mail: fatemeh.zehtabi@gmail.com; Lerouge, Sophie, E-mail: Sophie.Lerouge@etsmtl.ca
IntroductionOnyx and ethanol are well-known embolic and sclerotic agents that are frequently used in embolization. These agents present advantages and disadvantages regarding visibility, injection control and penetration depth. Mixing both products might yield a new product with different characteristics. The aim of this study is to evaluate the injectability, radiopacity, and mechanical and occlusive properties of different mixtures of Onyx 18 and ethanol in vitro and in vivo (in a swine model).Materials and MethodsVarious Onyx 18 and ethanol formulations were prepared and tested in vitro for their injectability, solidification rate and shrinkage, cohesion and occlusive properties. In vivo tests weremore » performed using 3 swine. Ease of injection, radiopacity, cohesiveness and penetration were analyzed using fluoroscopy and high-resolution CT.ResultsAll mixtures were easy to inject through a microcatheter with no resistance or blockage in vitro and in vivo. The 50%-ethanol mixture showed delayed copolymerization with fragmentation and proximal occlusion. The 75%-ethanol mixture showed poor radiopacity in vivo and was not tested in vitro. The 25%-ethanol mixture showed good occlusive properties and accepted penetration and radiopacity.ConclusionMixing Onyx and ethanol is feasible. The mixture of 25% of ethanol and 75% of Onyx 18 could be a new sclero-embolic agent. Further research is needed to study the chemical changes of the mixture, to confirm the significance of the added sclerotic effect and to find out the ideal mixture percentages.« less
Gedikli, Ömer; Ekşi, Alay; Avcıoğlu, Yonca; Soylu, Ayşegül İdil; Yüksel, Serkan; Aksan, Gökhan; Gülel, Okan; Yılmaz, Özcan
2016-01-01
Introduction Neutrophil-to-lymphocyte ratio (NLR), which is an essential marker of inflammation, has been shown to be associated with adverse outcomes in various cardiovascular diseases in the literature. In this study we sought to evaluate the association between NLR and prognosis of acute pulmonary embolism (APE). Material and methods We retrospectively evaluated blood counts and clinical data of 142 patients with the diagnosis of pulmonary embolism (PE) from Ondokuz Mayis University Hospital between January 2006 and December 2012. The patients were divided into two groups according to NLR: NLR < 4.4 (low NLR group, n = 71) and NLR ≥ 4.4 (high NLR group, n = 71). Results Massive embolism (66.2% vs. 36.6%, p < 0.001) and in-hospital mortality (21.1%, 1.4%, p < 0.001) were higher in the high NLR group. In multivariate regression analysis NLR ≥ 5.7, systolic blood pressure (BP) < 90 mm Hg, serum glucose > 126 mg/dl, heart rate > 110 beats/min, and PCO2 < 35 or > 50 mm Hg were predictors of in-hospital mortality. The optimal NLR cutoff value was 5.7 for mortality in receiver operating characteristic (ROC) analysis. Having an NLR value above 5.7 was found to be associated with a 10.8 times higher mortality rate than an NLR value below 5.7. Conclusions In patients presenting with APE, NLR value is an independent predictor of in-hospital mortality and may be used for clinical risk classification. PMID:26925123
Kim, Kyoung Jin; Lee, Kang Won; Choi, Ju Hee; Sohn, Jang Wook; Kim, Min Ja; Yoon, Young Kyung
2016-08-01
Infective endocarditis involving the tricuspid valve is an uncommon condition, and a consequent haemothorax associated with pulmonary embolism is extremely rare. Particularly, there are no guidelines for the management of this complication. We describe a rare case of pulmonary embolism and infarction followed by a haemothorax due to infective endocarditis of the tricuspid valve caused by Streptococcus sanguinis. A 25-year-old man with a ventricular septal defect (VSD) presented with fever. On physical examination, his body temperature was 38.8 °C, and a grade III holosystolic murmur was heard. A chest X-ray did not reveal any specific findings. A transoesophageal echocardiogram showed a perimembranous VSD and echogenic material attached to the tricuspid valve. All blood samples drawn from three different sites yielded growth of pan-susceptible S. sanguinis in culture bottles. On day 12 of hospitalization, the patient complained of pleuritic chest pain without fever. Physical examination revealed reduced breathing sounds and dullness in the lower left thorax. On his chest computed tomography scan, pleural effusion with focal infarction and pulmonary embolism were noted on the left lower lung. Thoracentesis indicated the presence of a haemothorax. Our case was successfully treated using antibiotic therapy alone with adjunctive chest tube insertion, rather than with anticoagulation therapy for pulmonary embolism or cardiac surgery. When treating infective endocarditis caused by S. sanguinis, clinicians should include haemothorax in the differential diagnosis of patients complaining of sudden chest pain.
Wan, Jun; Gu, Weijin; Zhang, Xiaolong; Geng, Daoying; Lu, Gang; Huang, Lei; Zhang, Lei; Ge, Liang; Ji, Lihua
2014-01-01
Background Ruptured intracranial aneurysm (ICA) with bleb formation (RICABF) is a special type of ruptured ICA. However, the exact role and effectiveness of endovascular coil embolization (ECE) in RICABF is unknown. We aimed to investigate the effectiveness and safety of ECE of aneurysm neck for RICABF treatment. Material/Methods We retrospectively assessed consecutive patients who were hospitalized in our endovascular intervention center between October 2004 and May 2012. Overall, 86 patients underwent ECE of aneurysm neck for 86 RICABF. Treatments outcomes included secondary rupture/bleeding rate, aneurysm neck embolization rate, residual/recurrent aneurysm, intraoperative incidents, and post-embolization complications, as well as improvements in the Glasgow outcome scale (extended) (GOS-E). Results Complete occlusion was achieved in 72 aneurysms (72/86, 83.7%), while 12 aneurysms (12/86, 14.0%) had a residual neck, and 2 aneurysms (2/86, 2.3%) had a residual aneurysm. The postoperative GOS-E was 3 in 3 patients (3.5%), 4 in 10 patients (11.6%), and 5 in 73 patients (84.9%). Follow-up angiography was performed in all patients (mean 9.0 months, interquartile range of 9.0). Recurrence was found in 3 patients (3/86, 3.5%). No aneurysm rupture or bleeding was reported. Conclusions Our mid-term follow-up study showed that ECE of aneurysm neck was an effective and safe treatment modality for RICABF. The long-term effectiveness and safety of this interventional radiology technique need to be investigated in prospective and comparative studies. PMID:24986761
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Qi, E-mail: wqtjmu@gmail.com; Xiong, Bin, E-mail: herrxiong@126.com; Zheng, ChuanSheng, E-mail: hqzcsxh@sina.com
ObjectiveThis retrospective study reports our experience using splenic arterial particle embolization and coil embolization for the treatment of sinistral portal hypertension (SPH) in patients with and without gastric bleeding.MethodsFrom August 2009 to May 2012, 14 patients with SPH due to pancreatic disease were diagnosed and treated with splenic arterial embolization. Two different embolization strategies were applied; either combined distal splenic bed particle embolization and proximal splenic artery coil embolization in the same procedure for acute hemorrhage (1-step) or interval staged distal embolization and proximal embolization in the stable patient (2-step). The patients were clinically followed.ResultsIn 14 patients, splenic arterial embolizationmore » was successful. The one-step method was performed in three patients suffering from massive gastric bleeding, and the bleeding was relieved after embolization. The two-step method was used in 11 patients, who had chronic gastric variceal bleeding or gastric varices only. The gastric varices disappeared in the enhanced CT scan and the patients had no gastric bleeding during follow-up.ConclusionsSplenic arterial embolization, particularly the two-step method, proved feasible and effective for the treatment of SPH patients with gastric varices or gastric variceal bleeding.« less
[Nursing care of pulmonary embolism in out-of-hospital emergencies].
Carrión-Martínez, Aurora; Rivera-Caravaca, José Miguel
2016-01-01
Pulmonary embolism is one of the most severe venous thromboembolic diseases, both in mortality and the high number of associated complications and their impact on quality of life. The early hours are critical and proper management during this period can determine future sequels. Therefore, in the outpatient setting, nurses must have adequate knowledge and tools to act quickly and efficiently. In this paper, we present a case of a 77 year-old male in his home that after being discharged from a knee replacement surgery starts with symptoms compatible with pulmonary thromboembolism. A Nursing Care Process is performed, according to the functional patterns of Margory Gordon and a care plan is developed based on NNN taxonomy (NANDA, NOC, NIC). As main nursing diagnosis 'ineffective breathing pattern' is selected and as possible potential complication of the pulmonary embolism the 'pulmonary infarction' is chosen. The results obtained after conducting the care plan are satisfactory, improving the signs and symptoms presented by the patient, hence why we believe it is useful for nurses when facing similar clinical situations. Copyright © 2016 Elsevier España, S.L.U. All rights reserved.
STFT or CWT for the detection of Doppler ultrasound embolic signals.
Gonçalves, Ivo B; Leiria, Ana; Moura, M M M
2013-09-01
Aiming reliable detection and localization of cerebral blood flow and emboli, embolic signals were added to simulated middle cerebral artery Doppler signals and analysed. Short-time Fourier transform (STFT) and continuous wavelet transform (CWT) were used in the evaluation. The following parameters were used in this study: the powers of the embolic signals added were 5, 6, 6.5, 7, 7.5, 8 and 9 dB; the mother wavelets for CWT analysis were Morlet, Mexican hat, Meyer, Gaussian (order 4) and Daubechies (orders 4 and 8); and the thresholds for detection (equated in terms of false positive, false negative and sensitivity) were 2 and 3.5 dB for the CWT and STFT, respectively. The results indicate that although the STFT allows accurately detecting emboli, better time localization can be achieved with the CWT. Among the CWT, the current best overall results were obtained with Mexican Hat mother wavelet, with optimal results for sensitivity (100% detection rate) for nearly all emboli power values studied. Copyright © 2013 John Wiley & Sons, Ltd.
Cieslak, Kasia P; Huisman, Floor; Bais, Thomas; Bennink, Roelof J; van Lienden, Krijn P; Verheij, Joanne; Besselink, Marc G; Busch, Olivier R C; van Gulik, Thomas M
2017-07-01
Preoperative portal vein embolization is widely used to increase the future remnant liver. Identification of nonresponders to portal vein embolization is essential because these patients may benefit from associating liver partition and portal vein ligation for staged hepatectomy (ALPPS), which induces a more powerful hypertrophy response. 99m Tc-mebrofenin hepatobiliary scintigraphy is a quantitative method for assessment of future remnant liver function with a calculated cutoff value for the prediction of postoperative liver failure. The aim of this study was to analyze future remnant liver function before portal vein embolization to predict sufficient functional hypertrophy response after portal vein embolization. Sixty-three patients who underwent preoperative portal vein embolization and computed tomography imaging were included. Hepatobiliary scintigraphy was performed to determine pre-portal vein embolization and post-portal vein embolization future remnant liver function. Receiver operator characteristic analysis of pre-portal vein embolization future remnant liver function was performed to identify patients who would meet the post-portal vein embolization cutoff value for sufficient function (ie, 2.7%/min/m 2 ). Mean pre-portal vein embolization future remnant liver function was 1.80% ± 0.45%/min/m 2 and increased to 2.89% ± 0.97%/min/m 2 post-portal vein embolization. Receiver operator characteristic analysis in 33 patients who did not receive chemotherapy revealed that a pre-portal vein embolization future remnant liver function of ≥1.72%/min/m 2 was able to identify patients who would meet the safe future remnant liver function cutoff value 3 weeks after portal vein embolization (area under the curve = 0.820). The predictive value was less pronounced in 30 patients treated with neoadjuvant chemotherapy (area under the curve = 0.618). A total of 45 of 63 patients underwent liver resection, of whom 5 of 45 developed postoperative liver failure; 4 of 5 patients had a post-portal vein embolization future remnant liver function below the cutoff value for safe resection. When selecting patients for portal vein embolization, future remnant liver function assessed with hepatobiliary scintigraphy can be used as a predictor of insufficient functional hypertrophy after portal vein embolization, especially in nonchemotherapy patients. These patients are potential candidates for ALPPS. Copyright © 2017 Elsevier Inc. All rights reserved.
Wen, Li-Li; Zhang, Xin; Zhang, Qing-Rong; Wu, Qi; Chen, Shu-Juan; Deng, Jin-Long; Huang, Kaiyi; Wang, Han-Dong
2017-11-01
Preoperative embolization of hypervascular brain tumors is frequently used to minimize intraoperative bleeding. To explore the efficacy of embolization using flat-detector CT (FDCT) parenchymal blood volume (PBV) maps before and after the intervention. Twenty-five patients with hypervascular brain tumors prospectively received pre- and postprocedural FDCT PBV scans using a biplane system under a protocol approved by the institutional research ethics committee. Semiquantitative analysis, based on region of interest measurements of the pre- and post-embolization PBV maps, operating time, and blood loss, was performed to assess the feasibility of PBV maps in detecting the perfusion deficit and to evaluate the efficacy of embolization. Preoperative embolization was successful in 18 patients. The relative PBV decreased significantly from 3.98±1.41 before embolization to 2.10±2.00 after embolization. Seventeen patients underwent surgical removal of tumors 24 hours after embolization. The post-embolic tumor perfusion index correlated significantly with blood loss (ρ=0.55) and operating time (ρ=0.60). FDCT PBV mapping is a useful method for evaluating the perfusion of hypervascular brain tumors and the efficacy of embolization. It can be used as a supplement to CT perfusion, MRI, and DSA in the evaluation of tumor embolization. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
Stein, Paul D; Yaekoub, Abdo Y; Matta, Fadi; Kleerekoper, Michael
2008-12-01
To assess the incidence and risk factors for fat embolism syndrome. Data from the National Hospital Discharge Survey (NHDS) were analyzed using International Classification of Diseases, Ninth Revision, Clinical Modification (ICD-9-CM) codes. From 1979 through 2005 among 928,324,000 patients discharged from short-stay hospitals in the United States, 41,000 (0.004%) had fat embolism syndrome. Among 21,538,000 patients with an isolated fracture of the femur (any site), tibia, fibula, pelvis, ribs, humerus, radius, or ulna, 25,000 (0.12%) developed fat embolism syndrome. Patients with multiple fractures of the femur (excluding neck) more often had fat embolism syndrome than those with isolated fractures (1.29% versus 0.54%). The incidence of fat embolism syndrome was lower with isolated fractures of the tibia or fibula (0.30%) and even lower with isolated fractures of the neck of the femur (0.06%). The incidence of fat embolism was too low to calculate with isolated fractures of the pelvis, ribs, humerus, radius, or ulna. Nonorthopedic conditions rarely, if ever, were accompanied by fat embolism syndrome. The fat embolism syndrome was more frequent in men (relative risk 5.71). Children, aged 0 to 9 years rarely had fat embolism syndrome. The fat embolism syndrome most commonly affected patients aged 10 to 39 years. The incidence of the fat embolism syndrome depends on the bone involved, whether fractures are isolated or multiple, the age of the patient and the gender. It rarely occurs as a result of medical conditions.
Elastoplasty: First Experience in 12 Patients
DOE Office of Scientific and Technical Information (OSTI.GOV)
Urlings, Thijs A. J., E-mail: t_urlings@hotmail.com; Linden, Edwin van der
Percutaneous vertebroplasty with polymethylmethacrylate (PMMA) is used increasingly for pain relief in symptomatic neoplastic or osteoporotic compression fractures. However, restoration of the stiffness of the treated vertebrae might propagate secondary fracture of adjacent vertebrae. Elastoplasty might prevent these secondary fractures. We assessed retrospectively our experience with elastoplasty in 12 patients, focusing on silicone migration. During the period from July 2011 to January 2012, all patients with an indication for vertebroplasty were treated with elastoplasty. The exclusion criterion was the presence of posterior wall defects. Chest computed tomography (CT) scans were performed to evaluate the presence of perivertebral leakage and pulmonarymore » embolism. The prevalence of leakage was compared with the results obtained for vertebroplasty with PMMA reported in the literature. Other complications during the postprocedural period were recorded. Twenty-one vertebral bodies in 12 patients were treated with elastoplasty. Silicone pulmonary emboli were detected on the postprocedural chest CT in 60 % (6/10) of the patients. Leakage to the perivertebral venous plexus was seen in 67 % (14/21) of the treated vertebrae. One major complication occurred: severe, medication-resistant dyspnea developed in one patient with multiple peripheral silicone emboli. This preliminary evidence suggests that VK100 silicone cement should not be used in elastoplasty because of the increased risk of silicone pulmonary embolism, when compared with the use of PMMA, which occurs worldwide. The major technical disadvantage is that the time taken for the VK100 silicone material to achieve its final strength is too long for practical application.« less
Marty, Alan T; Hilton, Frank L; Spear, Robert K; Greyson, Bruce
2005-11-01
Survival after surgical embolectomy for massive postcesarean pulmonary embolism causing sustained cardiac arrest is rare. One day after an uneventful cesarean delivery, a woman developed cardiac asystole and apnea due to pulmonary embolism. Femoral-femoral cardiopulmonary bypass performed during continuous cardiopulmonary resuscitation allowed a successful embolectomy. Upon awakening, the patient reported a near-death experience. Pulmonary embolism causes approximately 2 deaths per 100,000 live births per year in the United States, and postcesarean pulmonary embolism is probably more common than pulmonary embolism after vaginal delivery. Massive pulmonary embolism is a potentially treatable catastrophic event after cesarean delivery, even if continuous cardiopulmonary resuscitation is required until life-saving embolectomy is done.
Klein, Sabine; Hinüber, Christian; Hittatiya, Kanishka; Schierwagen, Robert; Uschner, Frank Erhard; Strassburg, Christian P; Fischer, Hans-Peter; Spengler, Ulrich; Trebicka, Jonel
2016-01-01
Non-cirrhotic idiopathic portal hypertension (NCIPH) is characterized by splenomegaly, anemia and portal hypertension, while liver function is preserved. However, no animal models have been established yet. This study assessed a rat model of NCIPH and characterized the hemodynamics, and compared it to human NCIPH. Portal pressure (PP) was measured invasively and coloured microspheres were injected in the ileocecal vein in rats. This procedure was performed weekly for 3 weeks (weekly embolization). Rats without and with single embolization served as controls. After four weeks (one week after last embolization), hemodynamics were investigated, hepatic fibrosis and accumulation of myofibroblasts were analysed. General characteristics, laboratory analyses and liver histology were collected in patients with NCIPH. Weekly embolization induced a hyperdynamic circulation, with increased PP. The mesenteric flow and hepatic hydroxyproline content was significantly higher in weekly embolized compared to single embolized rats (mesenteric flow +54.1%, hydroxyproline +41.7%). Mesenteric blood flow and shunt volumes increased, whereas splanchnic vascular resistance was decreased in the weekly embolization group. Fibrotic markers αSMA and Desmin were upregulated in weekly embolized rats. This study establishes a model using repetitive embolization via portal veins, comparable with human NCIPH and may serve to test new therapies.
Inferior Vena Cava Filters in Elderly Patients with Stable Acute Pulmonary Embolism.
Stein, Paul D; Matta, Fadi; Hughes, Mary J
2017-03-01
Patients aged >60 years with pulmonary embolism who were stable and did not require thrombolytic therapy were shown to have a somewhat lower in-hospital all-cause mortality with vena cava filters. In this investigation we further assess mortality with filters in stable elderly patients. In-hospital all-cause mortality according to use of inferior vena cava filters was assessed from the National (Nationwide) Inpatient Sample, 2003-2012, in: 1) All patients with pulmonary embolism; 2) All with pulmonary embolism who had none of the comorbid conditions listed in the Charlson Comorbidity Index; 3) Patients with a primary (first-listed) diagnosis of pulmonary embolism, and 4) Patients with a primary diagnosis of pulmonary embolism and none of the comorbid conditions listed in the Charlson Comorbidity Index. From 2003-2012, 2,621,575 stable patients with pulmonary embolism were hospitalized in the US. Patients aged >80 years showed lower mortality with vena cava filters (all pulmonary embolism, 6.1% vs 10.5%; all pulmonary embolism with no comorbid conditions, 3.3% vs 6.3%; primary pulmonary embolism, 4.1% vs 5.7%; primary pulmonary embolism with no comorbid conditions, 2.1% vs 3.7%; all P <.0001). In the all-patient category, patients aged 71-80 years showed somewhat lower mortality with filters, 6.3% vs 7.4% (P <.0001), and those without comorbid conditions, 2.5% vs 2.8% (P = .04). Those aged 71-80 years with primary pulmonary embolism, irrespective of comorbid conditions, did not show lower mortality with filters. At present, in the absence of a randomized controlled trial, it seems prudent to consider a vena cava filter in very elderly (aged >80 years) stable patients with acute pulmonary embolism. Copyright © 2016 Elsevier Inc. All rights reserved.
Vira, Shaleen; Ramme, Austin J; Alaia, Michael J; Steiger, David; Vigdorchik, Jonathan M; Jaffe, Frederick
2016-07-01
Duplex ultrasound is routinely used to evaluate suspected deep venous thrombosis after total joint arthroplasty. When there is a clinical suspicion for a pulmonary embolism, a chest angiogram (chest CTA) is concomitantly obtained. Two questions were addressed: First, for the population of patients who receive duplex ultrasound after total joint arthroplasty, what is the rate of positive results? Second, for these patients, how many of these also undergo chest CTA for clinical suspicion of pulmonary embolus and how many of these tests are positive? Furthermore, what is the correlation between duplex ultrasound results and chest CTA results? A retrospective chart review was conducted of total joint replacement patients in 2011 at a single institution. Inclusion criteria were adult patients who underwent a postoperative duplex ultrasonography for clinical suspicion of deep venous thrombosis (DVT). Demographic data, result of duplex scan, clinical indications for obtaining the duplex scan, and DVT prophylaxis used were recorded. Additionally, if a chest CTA was obtained for clinical suspicion for pulmonary embolus, results and clinical indication for obtaining the test were recorded. The rate of positive results for duplex ultrasonography and chest CTA was computed and correlated based on clinical indications. Two hundred ninety-five patients underwent duplex ultrasonography of which only 0.7% were positive for a DVT. One hundred three patients underwent a chest CTA for clinical suspicion of a pulmonary embolism (PE) of which 26 revealed a pulmonary embolus, none of which had a positive duplex ultrasound. Postoperative duplex scans have a low rate of positive results. A substantial number of patients with negative duplex results subsequently underwent chest CTA for clinical suspicion for which a pulmonary embolus was found, presumably resulting from a DVT despite negative duplex ultrasound result. A negative duplex ultrasonography should not rule out the presence of a DVT which can embolize to the lungs and thus should not preclude further workup when clinical suspicion exists for a pulmonary embolus.
Gaynor, Brandon G; Elhammady, Mohamed Samy; Jethanamest, Daniel; Angeli, Simon I; Aziz-Sultan, Mohammad A
2014-02-01
The resection of glomus jugulare tumors can be challenging because of their inherent vascularity. Preoperative embolization has been advocated as a means of reducing operative times, blood loss, and surgical complications. However, the incidence of cranial neuropathy associated with the embolization of these tumors has not been established. The authors of this study describe their experience with cranial neuropathy following transarterial embolization of glomus jugulare tumors using ethylene vinyl alcohol (Onyx, eV3 Inc.). The authors retrospectively reviewed all cases of glomus jugulare tumors that had been treated with preoperative embolization using Onyx at their institution in the period from 2006 to 2012. Patient demographics, clinical presentation, grade and amount of Onyx used, degree of angiographic devascularization, and procedural complications were recorded. Over a 6-year period, 11 patients with glomus jugulare tumors underwent preoperative embolization with Onyx. All embolization procedures were completed in one session. The overall mean percent of tumor devascularization was 90.7%. No evidence of nontarget embolization was seen on postembolization angiograms. There were 2 cases (18%) of permanent cranial neuropathy attributed to the embolization procedures (facial nerve paralysis and lower cranial nerve dysfunction). Embolizing glomus jugulare tumors with Onyx can produce a dramatic reduction in tumor vascularity. However, the intimate anatomical relationship and overlapping blood supply between these tumors and cranial nerves may contribute to a high incidence of cranial neuropathy following Onyx embolization.
Marcelin, C; Izaaryene, J; Castelli, M; Barral, P A; Jacquier, A; Vidal, V; Bartoli, J M
2017-12-01
To evaluate the safety and efficacy of pelvic embolization using ethylene vinyl alcohol copolymer (Onyx ® ) for pelvic congestion syndrome. Between March 2012 to September 2016, 17 women (mean age, 44.7± 12.2 (SD) years; range: 34-71years) presenting with pelvic congestion syndrome were evaluated for transvenous embolization with Onyx ® . Pelvic congestion syndrome was initially diagnosed by clinical examination and the results of transvaginal Doppler ultrasound and further confirmed by pelvic venography. Primary and secondary clinical efficacy was defined respectively by the resolution of the symptoms after embolization and at the end of the follow-up, irrespective to the number of embolization procedures. Technical efficacy of embolization was 100% with no significant complications during and after embolization. After a mean follow-up time of 24.2 months (range: 6-69months) a primary and secondary clinical efficacy of 76.4% (13/17 women) and 94.1% (16/17 women) respectively were observed. Four women (23.5%) underwent a second embolization procedure with one woman requiring a third embolization procedure. These additional embolization procedures were associated with direct puncture of vulvar varices for sclerotherapy in two women. Five women (29%) had recurrent symptoms 21 months post-treatment (7-42months). Pelvic embolization using ethylene vinyl alcohol copolymer (Onyx ® ) has a favorable clinical success for pelvic congestion syndrome. Copyright © 2017. Published by Elsevier Masson SAS.
Ren, Y M; Wu, X M; Wen, Y; Lai, Q; Chen, W Z; Qian, Y X; Liang, R G
2017-01-03
Objective: To explore the causes and countermeasure in recurrent bleeding following the selective renal artery embolization treating post-percutaneous nephrolithotomy hemorrhage. Methods: A total of 334 patients of severe renal hemorrhage associated with percutaneous nephrolithotomy (PCNL) from March 2011 to April 2015 were analyzed retrospectively.All the patients underwent super selective angiography and renal artery embolization.The causes of recurrent hemorrhage were analyzed and principles for diagnosis and embolization were studied. Results: The initial embolization was performed in 329 cases hospitalized in the First Affiliated Hospital of Guangzhou Medical University and 318 cases were successfully stopped bleeding with a hemostatic rate of 96.7 %(318/329). Of total 334 consecutive cases, there were 16 cases of recurrent renal hemorrhage, 11 cases were initially embolized in this hospital, and otherwise the other 5 cases were in other hospitals. Causes of recurrent hemorrhage were missed embolization of tiny pseudoaneurysm ( n =12), and two cases of 12, the tiny pseudoaneurysm were feeding by accessory renal arteries, undetected arteriovenous fistula( n =2), recanalization of the embolized arteries ( n =2). Conclusion: The causes of recurrent bleeding fallowing the initial selective renal artery embolization treating post-percutaneous nephrolithotomy hemorrhage are varied, and missed embolization of tiny pseudoaneurysm is the major cause of unsuccessful initial renal artery embolization. To strengthen the understanding of tiny pseudoaneurysm is helpful to improve the success rate of hemostasis.
Cerebral Arterial Gas Embolism During Upper Endoscopy.
Eoh, Eun J; Derrick, Bruce; Moon, Richard
2015-09-15
Arterial gas embolism can be caused by direct entry of gas into systemic arteries or indirectly by venous-to-arterial shunting. Although arterial gas embolism is rare, most documented cases are iatrogenic, resulting from the entry of gas during procedures that involve direct vascular cannulation or intracavitary air insufflation. Of the 18 identified case reports of air embolism during endoscopy, 11 cases describe findings of cerebral arterial gas embolism during upper endoscopy. Only 1 of these occurred during endoscopic balloon dilation of an esophageal stricture. We report a rare case of cerebral arterial gas embolism in a 64-year-old woman, which occurred during endoscopic dilation of an esophageal stricture and was subsequently treated with hyperbaric oxygen therapy. In this case report, we explore the possible etiologies, clinical workup, and therapeutic management of cerebral artery gas embolisms. Hyperbaric oxygen therapy is the treatment of choice for cerebral arterial gas embolism, with earlier treatments resulting in better outcomes.
Yang, Heechul; Lee, Chun Kyon; Kim, Gun Bea
2016-01-01
Purpose To evaluate the technical feasibility and safety of vascular plug assisted retrograde transvenous obliteration (PARTO) for bleeding gastric varix performed in the emergent clinical setting and describe the mid-term clinical results. Materials and Methods From April 2012 to January 2015, emergent PARTO was tried in total 9 patients presented with active gastric varix bleeding. After initial insufficient or failure of endoscopic approach, they underwent PARTO in the emergent clinical setting. Gelatin sponge embolization of both gastrorenal (GR) shunt and gastric varix was performed after retrograde transvenous placement of a vascular plug in GR shunt. Coil assisted RTO (CARTO) was performed in one patient who had challenging GR shunt anatomy for vascular plug placement. Additional embolic materials, such as microcoils and NBCA glue-lipiodol mixture, were required in three patients to enhance complete occlusion of GR shunt or obliteration of competitive collateral vessels. Clinical success was defined as no variceal rebleeding and disappearance of gastric varix. Results All technical and clinical success–i.e., complete GR shunt occlusion and offending gastric varix embolization with immediate bleeding control–was achieved in all 9 patients. There was no procedure-related complication. All cases showed successful clinical outcome during mean follow up of 17 months (12–32 months), evidenced by imaging studies, endoscopy and clinical data. In 4 patients, mild worsening of esophageal varices or transient ascites was noted as portal hypertensive related change. Conclusion Emergent PARTO is technically feasible and safe, with acceptable mid-term clinical results, in treating active gastric varix bleeding. PMID:27189294
Ocular Pain and Impending Blindness During Facial Cosmetic Injections: Is Your Office Prepared?
Prado, Giselle; Rodríguez-Feliz, Jose
2017-02-01
Soft tissue filler injections are the second most common non-surgical procedure performed by the plastic surgeon. Embolization of intravascular material after facial injection is a rare but terrifying outcome due to the high likelihood of long-term sequela such as blindness and cerebrovascular accident. The literature is replete with examples of permanent blindness caused by injection with autologous fat, soft tissue fillers such as hyaluronic acid, PLLA, calcium hydroxyl-apatite, and even corticosteroid suspensions. However, missing from the discussion is an effective treatment algorithm that can be quickly and safely followed by injecting physicians in the case of an intravascular injection with impending blindness. In this report, we present the case of a 64-year-old woman who suffered from blindness and hemiparesis after facial cosmetic injections performed by a family physician. We use this case to create awareness that this complication has become more common as the number of injectors and patients seeking these treatments have increased exponentially over the past few years. We share in this study our experience with the incorporation of a "blindness safety kit" in each of our offices to promptly initiate treatment in someone with embolization and impending blindness. The kit contains a step-by-step protocol to follow in the event of arterial embolization of filler material associated with ocular pain and impending loss of vision. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .
Treatment of Recurrent Hemarthrosis after Total Knee Arthroplasty
Yoo, Ju-Hyung; Oh, Hyun-Cheol; Park, Sang-Hoon; Lee, Sanghyeon; Lee, Yunjae
2018-01-01
Purpose The purpose of this study is to evaluate the incidence and treatment of recurrent hemarthrosis after total knee replacement (TKR). Materials and Methods Among a total of 5,510 patients who underwent TKR from March 2000 to October 2016, patients who had two or more bleeding 2 weeks after surgery were studied. Conservative treatments were performed for all cases with symptoms. In patients who did not respond to conservative treatment several times, embolization was performed. We retrospectively evaluated the postoperative bleeding time, bleeding frequency, treatment method, and outcome. Results Seventeen (0.3%) of the 5,510 patients developed recurrent hemarthrosis. Bleeding occurred at an average of 2 years 3 months after the operation. Joint aspiration was performed 3.5 times (range, 2 to 10 times) on average, and 14 cases (82.3%) were treated with conservative treatment. In 3 patients with severe bleeding and hemorrhage, embolization was performed. Conclusions Recurrent hemarthrosis after TKR is a rare disease with a low incidence of 0.3% and usually could be treated by conservative treatment. If recurrences occur repeatedly, embolization through angiography or surgical treatment may be considered, but the results are not satisfactory and careful selection of treatment modalities is warranted. PMID:29715715
Conservative management of retained cardiac missiles: case report and literature review.
Lundy, Jonathan B; Johnson, Eric K; Seery, Jason M; Pham, Tach; Frizzi, James D; Chasen, Arthur B
2009-01-01
Intracardiac foreign bodies may be caused by direct penetrating trauma, embolization from injury to another area of the body, or iatrogenically from fragments of intravascular access devices. Penetrating cardiac trauma commonly presents with a hemodynamically unstable patient necessitating emergent life-saving procedures. Missile embolization to the heart can occur after injury to systemic and pulmonary veins. Central venous access devices may fracture after placement and embolize. Especially in the setting of penetrating cardiac trauma, these intracardiac foreign bodies require expeditious removal. Limited data exist regarding the conservative management of intracardiac material after trauma. We present the case of a 42-year-old male soldier injured in a mortar blast in Iraq who suffered multiple injuries to include a right hemopneumothorax and soft tissue injuries to the chest and both lower extremities that was found to have a 2-cm by 2-mm intracardiac metal fragment. Additional imaging revealed a metallic fragment localized to the interatrial septum. The patient suffered no adverse sequelae from nonoperative management. A review of the world literature regarding the subject of posttraumatic retained cardiac missiles (RCMs) is also included to help future surgeons in the management of this rare entity.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dixon, Shaheen, E-mail: shaheen7noorani@gmail.com; Chan, Victoria, E-mail: dr.victoriac@gmail.com; Shrivastava, Vivek, E-mail: vivshriv@yahoo.com
2013-08-01
PurposeTo assess the relative efficacy of empiric gastroduodenal artery (GDA) embolization in reducing recurrent hemorrhage compared to image-guided targeted embolization.MethodsData were retrospectively collected for consecutive patients who had catheter angiography for major upper gastrointestinal hemorrhage from May 2008 to November 2010 (n = 40). The total number of cases were divided into two main groups according to angiographic findings: those that demonstrated a site of hemorrhage on catheter angiography (group 1, n = 13), and those where the site of hemorrhage was not identified on catheter angiography (group 2, n = 27). Group 2 was then further divided into patientsmore » who received empiric embolization (group 2a, n = 20) and those who had no embolization performed after angiography (group 2b, n = 7).ResultsThe technical and clinical success rates for embolization in groups 1 and 2a were, respectively, 100 vs. 95 %, and 85 vs. 80 %. There was no statistical significance in the recurrent hemorrhage rate, reintervention rate, or 30 day mortality between targeted and empiric embolization groups. There were no complications attributed to embolization within this study cohort.ConclusionCases of duodenal-related major upper gastrointestinal hemorrhage where no embolization is performed have poor outcome. Empiric embolization of the GDA in patients with major upper gastrointestinal hemorrhage refractory to endoscopic treatment appears to be a safe and effective treatment, with low reintervention rates and good clinical outcome comparable to patients where the site of hemorrhage is localized and embolized with computed tomographic angiography or catheter angiography and embolized.« less
A survey of root pressure in 53 Asian species of bamboo
Fusheng Wang; Xinli Tian; Yulong Ding; Xianchong Wan; M. T. Tyree
2011-01-01
Introduction. Root pressure is a potentially important mechanism for dissolving embolisms in previously cavitated vessels, but the occurrence of root pressure is not a universal property in plants. Material and methods. We suggest that root pressure might be more common in monocots than dicots because in dicots, cambial growth...
Design and Verification of a Shape Memory Polymer Peripheral Occlusion Device
Landsman, Todd L.; Bush, Ruth L.; Glowczwski, Alan; Horn, John; Jessen, Staci L.; Ungchusri, Ethan; Diguette, Katelin; Smith, Harrison R.; Hasan, Sayyeda M.; Nash, Daniel; Clubb, Fred J.; Maitland, Duncan J.
2017-01-01
Shape memory polymer foams have been previously investigated for their safety and efficacy in treating a porcine aneurysm model. Their biocompatibility, rapid thrombus formation, and ability for endovascular catheter-based delivery to a variety of vascular beds makes these foams ideal candidates for use in numerous embolic applications, particularly within the peripheral vasculature. This study sought to investigate the material properties, safety, and efficacy of a shape memory polymer peripheral embolization device in vitro. The material characteristics of the device were analyzed to show tunability of the glass transition temperature (Tg) and the expansion rate of the polymer to ensure adequate time to deliver the device through a catheter prior to excessive foam expansion. Mechanical analysis and flow migration studies were performed to ensure minimal risk of vessel perforation and undesired thromboembolism upon device deployment. The efficacy of the device was verified by performing blood flow studies that established affinity for thrombus formation and blood penetration throughout the foam and by delivery of the device in an ultrasound phantom that demonstrated flow stagnation and diversion of flow to collateral pathways. PMID:27419615
Design and verification of a shape memory polymer peripheral occlusion device.
Landsman, Todd L; Bush, Ruth L; Glowczwski, Alan; Horn, John; Jessen, Staci L; Ungchusri, Ethan; Diguette, Katelin; Smith, Harrison R; Hasan, Sayyeda M; Nash, Daniel; Clubb, Fred J; Maitland, Duncan J
2016-10-01
Shape memory polymer foams have been previously investigated for their safety and efficacy in treating a porcine aneurysm model. Their biocompatibility, rapid thrombus formation, and ability for endovascular catheter-based delivery to a variety of vascular beds makes these foams ideal candidates for use in numerous embolic applications, particularly within the peripheral vasculature. This study sought to investigate the material properties, safety, and efficacy of a shape memory polymer peripheral embolization device in vitro. The material characteristics of the device were analyzed to show tunability of the glass transition temperature (Tg) and the expansion rate of the polymer to ensure adequate time to deliver the device through a catheter prior to excessive foam expansion. Mechanical analysis and flow migration studies were performed to ensure minimal risk of vessel perforation and undesired thromboembolism upon device deployment. The efficacy of the device was verified by performing blood flow studies that established affinity for thrombus formation and blood penetration throughout the foam and by delivery of the device in an ultrasound phantom that demonstrated flow stagnation and diversion of flow to collateral pathways. Copyright © 2016 Elsevier Ltd. All rights reserved.
Jeon, Jin Pyeong; Rhim, Jong Kook; Park, Jeong Jin; Cho, Won-Sang; Kang, Hyun-Seung; Kim, Jeong Eun; Hwang, Gyojun; Kwon, O-Ki; Han, Moon Hee
2016-01-01
Objective Outcomes of stent-assisted coil embolization (SACE) have not been well established in the setting of vertebrobasilar dissecting aneurysms (VBDAs) due to the low percentage of cases that need treatment and the array of available therapeutic options. Herein, we presented clinical and radiographic results of SACE in patients with VBDAs. Materials and Methods A total of 47 patients (M:F, 30:17; mean age ± SD, 53.7 ± 12.6 years), with a VBDA who underwent SACE between 2008 and 2014 at two institutions were evaluated retrospectively. Medical records and radiologic data were analyzed to assess the outcome of SACE procedures. Cox proportional hazards regression analysis was conducted to determine the factors that were associated with aneurysmal recanalization after SACE. Results Stent-assisted coil embolization technically succeeded in all patients. Three cerebellar infarctions occurred on postembolization day 1, week 2, and month 2, but no other procedure-related complications developed. Immediately following SACE, 25 aneurysms (53.2%) showed no contrast filling into the aneurysmal sac. During a mean follow-up of 20.2 months, 37 lesions (78.7%) appeared completely occluded, whereas 10 lesions showed recanalization, 5 of which required additional embolization. Overall recanalization rate was 12.64% per lesion-year, and mean postoperative time to recanalization was 18 months (range, 3–36 months). In multivariable analysis, major branch involvement (hazard ratio [HR]: 7.28; p = 0.013) and the presence of residual sac filling (HR: 8.49, p = 0.044) were identified as statistically significant independent predictors of recanalization. No bleeding was encountered in follow-up monitoring. Conclusion Stent-assisted coil embolization appears feasible and safe for treatment of VBDAs. Long-term results were acceptable in a majority of patients studied, despite a relatively high rate of incomplete occlusion immediately after SACE. Major branch involvement and coiled aneurysms with residual sac filling may predispose to recanalization. PMID:27587971
Hill, Hannah; Srinivasa, Ravi N; Gemmete, Joseph J; Hage, Anthony; Bundy, Jacob; Chick, Jeffrey Forris Beecham
2018-01-01
Purpose: To report the approach, technical success, clinical outcomes, complications, and follow-up of ethiodized oil intranodal lymphangiography with cyanoacrylate glue embolization for the treatment of lymphatic leak after robot-assisted laparoscopic pelvic resection. Materials and Methods: Four men with mean age 68.7 ± 14.3 years were treated with ethiodized oil intranodal lymphangiography with cyanoacrylate embolization for postoperative lymphatic leak. Patients underwent either (1) cystoprostatectomy with ileal conduit and bilateral extensive pelvic lymph node dissection for muscle-invasive urothelial carcinoma and presented with postoperative lymphatic ascites ( n = 2) or (2) prostatectomy with bilateral standard pelvic lymph node dissection for prostate carcinoma and presented with postoperative pelvic lymphoceles ( n = 2). Intranodal lymphangiography and embolization procedural details, technical success, clinical outcomes, and follow-up were recorded. Results: In four patients, a total of six ethiodized oil intranodal lymphangiograms were performed, two procedures being repeated interventions. Inguinal lymph node catheterization and ethiodized oil lymphangiography was technically effective in all procedures. A mean of 5.2 ± 2.0 mL of ethiodized oil was used for lymphatic opacification. Cyanoacrylate was diluted to 24.2% with ethiodized oil and 0.44 mL of cyanoacrylate was instilled during first time interventions. On repeat procedures, cyanoacrylate was diluted to 51.7%, and 0.52 mL was instilled. The primary clinical success rate was 50% ( n = 2/4). Clinical success was achieved in all patients after two interventions ( n = 4; 100%). No complications were reported at mean follow-up of 134.7 ± 79.2 days (range: 59-248 days). Conclusion: Ethiodized oil intranodal lymphangiography with direct cyanoacrylate glue embolization is a minimally invasive treatment option for lymphatic leak after pelvic resection.
Balloon-assisted embolization of skull base meningioma with liquid embolic agent.
Abdel Kerim, Amr; Bonneville, Fabrice; Jean, Betty; Cornu, Philippe; LeJean, Lise; Chiras, Jacques
2010-01-01
The authors report a novel technique of balloon-assisted embolization of a skull base meningioma supplied by a branch of the cavernous segment of the internal carotid artery using liquid embolic agent. A temporarily inflated balloon distal to the meningioma's feeding vessel may improve the access to this small branch and may reduce the chances of unintended reflux during delivery of the liquid embolic agent.
Guidelines for the Use of Echocardiography in the Evaluation of a Cardiac Source of Embolism.
Saric, Muhamed; Armour, Alicia C; Arnaout, M Samir; Chaudhry, Farooq A; Grimm, Richard A; Kronzon, Itzhak; Landeck, Bruce F; Maganti, Kameswari; Michelena, Hector I; Tolstrup, Kirsten
2016-01-01
Embolism from the heart or the thoracic aorta often leads to clinically significant morbidity and mortality due to transient ischemic attack, stroke or occlusion of peripheral arteries. Transthoracic and transesophageal echocardiography are the key diagnostic modalities for evaluation, diagnosis, and management of stroke, systemic and pulmonary embolism. This document provides comprehensive American Society of Echocardiography guidelines on the use of echocardiography for evaluation of cardiac sources of embolism. It describes general mechanisms of stroke and systemic embolism; the specific role of cardiac and aortic sources in stroke, and systemic and pulmonary embolism; the role of echocardiography in evaluation, diagnosis, and management of cardiac and aortic sources of emboli including the incremental value of contrast and 3D echocardiography; and a brief description of alternative imaging techniques and their role in the evaluation of cardiac sources of emboli. Specific guidelines are provided for each category of embolic sources including the left atrium and left atrial appendage, left ventricle, heart valves, cardiac tumors, and thoracic aorta. In addition, there are recommendation regarding pulmonary embolism, and embolism related to cardiovascular surgery and percutaneous procedures. The guidelines also include a dedicated section on cardiac sources of embolism in pediatric populations. Copyright © 2016 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.
Can Patients Comprehend the Educational Materials that Hospitals Provide about Common IR Procedures?
Sadigh, Gelareh; Hawkins, C Matthew; O'Keefe, John J; Khan, Ramsha; Duszak, Richard
2015-08-01
To assess the readability of online education materials offered by hospitals describing commonly performed interventional radiology (IR) procedures. Online patient education materials from 402 hospitals selected from the Medicare Hospital Compare database were assessed. The presence of an IR service was determined by representation in the Society of Interventional Radiology physician finder directory. Patient online education materials about (i) uterine artery embolization for fibroid tumors, (ii) liver cancer embolization, (iii) varicose vein treatment, (iv) central venous access, (v) inferior vena cava (IVC) filter placement, (vi) nephrostomy tube insertion, (vii) gastrostomy tube placement, and (viii) vertebral augmentation were targeted and assessed by using six validated readability scoring systems. Of 402 hospitals sampled, 156 (39%) were presumed to offer IR services. Of these, 119 (76%) offered online patient education material for one or more of the eight service lines. The average readability scores corresponding to grade varied between the ninth- and 12th-grade levels. All were higher than the recommended seventh-grade level (P < .05) except for nephrostomy and gastrostomy tube placement. Average Flesch-Kincaid Reading Ease scores ranged from 42 to 69, corresponding with fairly difficult to difficult readability for all service lines except IVC filter and gastrostomy tube placement, which corresponded with standard readability. A majority of hospitals offering IR services provide at least some online patient education material. Most, however, are written significantly above the reading comprehension level of most Americans. More attention to health literacy by hospitals and IR physicians is warranted. Copyright © 2015 SIR. Published by Elsevier Inc. All rights reserved.
Herbaceous Angiosperms Are Not More Vulnerable to Drought-Induced Embolism Than Angiosperm Trees.
Lens, Frederic; Picon-Cochard, Catherine; Delmas, Chloé E L; Signarbieux, Constant; Buttler, Alexandre; Cochard, Hervé; Jansen, Steven; Chauvin, Thibaud; Doria, Larissa Chacon; Del Arco, Marcelino; Delzon, Sylvain
2016-10-01
The water transport pipeline in herbs is assumed to be more vulnerable to drought than in trees due to the formation of frequent embolisms (gas bubbles), which could be removed by the occurrence of root pressure, especially in grasses. Here, we studied hydraulic failure in herbaceous angiosperms by measuring the pressure inducing 50% loss of hydraulic conductance (P 50 ) in stems of 26 species, mainly European grasses (Poaceae). Our measurements show a large range in P 50 from -0.5 to -7.5 MPa, which overlaps with 94% of the woody angiosperm species in a worldwide, published data set and which strongly correlates with an aridity index. Moreover, the P 50 values obtained were substantially more negative than the midday water potentials for five grass species monitored throughout the entire growing season, suggesting that embolism formation and repair are not routine and mainly occur under water deficits. These results show that both herbs and trees share the ability to withstand very negative water potentials without considerable embolism formation in their xylem conduits during drought stress. In addition, structure-function trade-offs in grass stems reveal that more resistant species are more lignified, which was confirmed for herbaceous and closely related woody species of the daisy group (Asteraceae). Our findings could imply that herbs with more lignified stems will become more abundant in future grasslands under more frequent and severe droughts, potentially resulting in lower forage digestibility. © 2016 American Society of Plant Biologists. All Rights Reserved.
Holst, H; Aström, K; Järund, A; Palmer, J; Heyden, A; Kahl, F; Tägil, K; Evander, E; Sparr, G; Edenbrandt, L
2000-04-01
The purpose of this study was to develop a completely automated method for the interpretation of ventilation-perfusion (V-P) lung scintigrams used in the diagnosis of pulmonary embolism. An artificial neural network was trained for the diagnosis of pulmonary embolism using 18 automatically obtained features from each set of V-P scintigrams. The techniques used to process the images included their alignment to templates, the construction of quotient images based on the ventilation and perfusion images, and the calculation of measures describing V-P mismatches in the quotient images. The templates represented lungs of normal size and shape without any pathological changes. Images that could not be properly aligned to the templates were detected and excluded automatically. After exclusion of those V-P scintigrams not properly aligned to the templates, 478 V-P scintigrams remained in a training group of consecutive patients with suspected pulmonary embolism, and a further 87 V-P scintigrams formed a separate test group comprising patients who had undergone pulmonary angiography. The performance of the neural network, measured as the area under the receiver operating characteristic curve, was 0.87 (95% confidence limits 0.82-0.92) in the training group and 0.79 (0.69-0.88) in the test group. It is concluded that a completely automated method can be used for the interpretation of V-P scintigrams. The performance of this method is similar to others previously presented, whereby features were extracted manually.
Ishimaru, Hideki; Nakashima, Kazuaki; Takahata, Hideaki; Matsuoka, Yohjiro
2013-02-01
Although stenting for stenotic vertebral artery dissection (VAD) improves compromised blood flow, subsequent peri-stent aneurysm (PSA) formation is not well-known. We report two cases with PSA successfully treated with coil embolization. Three patients with stenotic intracranial VAD underwent endovascular angioplasty at our institution because they had acute infarction in posterior circulation territory and clinical evidence of hemodynamic insufficiency. In two of three patients balloon angioplasty at first session failed to relieve the stenosis, and a coronary stent was implanted. Angiography immediately after stenting showed no abnormality in case 1 and minimal slit-like projection at proximal portion of the stent in case 2. Angiography obtained 16 months after the stenting revealed PSA in case 1. In case 2, angiography performed 3 months later showed that the projection at proximal portion enlarged and formed an aneurysm outside the stent. Because follow-up angiographies showed growth of the aneurysm in both cases, endovascular aneurysmal embolization was performed. We advanced a microcatheter into the aneurysm through the strut of existing stent and delivered detachable coils into the aneurysm lumen successfully in both cases. The post-procedural course was uneventful, and complete obliteration of aneurysm was confirmed on angiography in both cases. Stenting for stenotic intracranial VAD may result in delayed PSA; therefore, follow-up angiographies would be necessary after stenting for stenotic intracranial arterial dissection. Coil embolization through the stent strut would be a solution for enlarging PSA.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sato, Y.; Ogino, H.; Hara, M.
2003-11-15
Our objective was to evaluate the usefulness of embolizing collateral vessels using mechanically detachable coils (MDCs) in children aged 3 years or younger with congenital heart disease. The subjects were 8 children with congenital heart disease featuring collateral vessels (age 18 days-3 years): 3 with a single ventricle, 2 with the tetralogy of Fallot, 2 with pulmonary atresia, and 1 with a ventricular septal defect. The embolized vessels were the major aortopulmonary collateral artery (MAPCA) in 5 patients, the persistent left superior vena cava in 2, and the coronary arteriovenous fistula in 1. A 4 or a 5 F cathetermore » was used as the guiding device, and embolization was performed using MDCs and other conventional coils introduced through the microcatheter. One patient had growth of new MAPCAs after embolization, and these MAPCAs were also embolized with MDCs. Thus, a total of 9 embolization procedures were performed in 8 patients. Complete occlusion of the collateral vessels was achieved in 8 of 9 procedures (89%). Seven of 8 patients (88%) had uneventful courses after embolization, and MDC procedures appeared to play important roles in avoiding coil migration and achievement of safe coil embolization. One patient who underwent MAPCA embolization showed no improvement in heart function and died 2 months and 19 days later. Embolization of collateral vessels using MDCs in young children with congenital heart disease can be an effective procedure and a valuable adjunct to surgical management.« less
Barral, P-A; Saeed-Kilani, M; Tradi, F; Dabadie, A; Izaaryene, J; Soussan, J; Bartoli, J-M; Vidal, V
2017-05-01
The purpose of this study was to evaluate the effectiveness of ethylene vinyl alcohol copolymer (Onyx) as a single embolic agent for percutaneous arterial treatment of hemorrhage due to uterine arteriovenous malformations (AVMs). Twelve women (mean age, 33 years) with metrorrhagia due to uterine AVMs who were treated by percutaneous arterial embolization using Onyx as a single embolic agent were retrospectively included. The diagnosis of uterine AVM was suggested by pelvic ultrasound and/or magnetic resonance imaging findings and further confirmed by angiography. Clinical files and angiographic examinations were reviewed for angiographic findings, technical and clinical success, procedure complication and further pregnancies. Clinical success was defined by absence of metrorrhagia at 1 month following embolization. Sixteen arterial embolization procedures were performed. Angiographically, 6 women had high flow AVM and 6 had low flow AVM. The rate of technical and clinical success was 92% (11/12 patients). One woman with early repeat hemorrhage underwent two embolization procedures and further hysterectomy. No severe complications were observed after embolization. Three women (3/12; 25%) became pregnant following embolization including one full term pregnancy. In women with metrorrhagia due to AVM, arterial embolization with Onyx is effective and safe. Additional research is needed to confirm the possibility of future pregnancy after Onyx embolization. Copyright © 2016 Éditions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.
A Study on Cerebral Embolism in Mitral Stenosis
Kwon, Osun; Kim, Myung Hwan; Kim, Kwon Sam; Bae, Jong Hoa; Kim, Myung Shick; Song, Jung Sang
1986-01-01
To evaluate the significance of episodes of cerebral embolism in patients with mitral valve disease in Korea, 128 patients with echocardiographic diagnosis of mitral valve disease were examined. Among these, 82 patients had predominant mitral stenosis. The clinical features of 82 patients with mitral stenosis have been reviewed to elucidate the factors favoring cerebral embolism which occurred in 19 patients, i.e., incidence of 23.2%.Atrial fibrillation was present in 16 of 19 patients with cerebral embolism (84.2%). Cerebral embolic episodes occurred in 16 of 47 patients with atrial fibrillation (34.0%).The mean age (55.3 ± 12.1 years) of patients without cerebral embolism was significantly older than that (43.2 ± 14.6 years) of patients without cerebral embolism (P<0.005).There was no significant relationship between the incidence of embolism and sex, left atrial thrombi, left atrium/aortic root diameter, mitral valvular orifice area, mitral valvular vegetation or calcification, left ventricular enddiastolic dimension or left ventricular posterior wall thickness. Cerebral embolism is common in patients with mitral stenosis in our country. The presence of atrial fibrillation and low cardiac output increase the attack of cerebral emboli whereas the severity of mitral stenosis, as judged by valve area, may not correlate with the occurrence of emboli. The best treatment for cerebral embolism is prevention. Therefore, we believe that more vigorous treatment of patients with mitral valve disease who are old or associated with atrial fibrillation as well as previous embolic history is indicated. PMID:15759378
High D-dimer levels after stopping anticoagulants in pulmonary embolism with sleep apnoea.
García Suquia, Angela; Alonso-Fernández, Alberto; de la Peña, Mónica; Romero, David; Piérola, Javier; Carrera, Miguel; Barceló, Antonia; Soriano, Joan B; Arque, Meritxell; Fernández-Capitán, Carmen; Lorenzo, Alicia; García-Río, Francisco
2015-12-01
Obstructive sleep apnoea is a risk factor for pulmonary embolism. Elevated D-dimer levels and other biomarkers are associated with recurrent pulmonary embolism. The objectives were to compare the frequency of elevated D-dimer levels (>500 ng·mL(-1)) and further coagulation biomarkers after oral anticoagulation withdrawal in pulmonary embolism patients, with and without obstructive sleep apnoea, including two control groups without pulmonary embolism.We performed home respiratory polygraphy. We also measured basic biochemical profile and haemogram, and coagulation biomarkers (D-dimer, prothrombin fragment 1+2, thrombin-antithrombin complex, plasminogen activator inhibitor 1, and soluble P-selectin).64 (74.4%) of the pulmonary embolism cases and 41 (46.11%) of the controls without pulmonary embolism had obstructive sleep apnoea. Plasmatic D-dimer was higher in PE patients with OSA than in those without obstructive sleep apnoea. D-dimer levels were significantly correlated with apnoea-hypopnoea index, and nocturnal hypoxia. There were more patients with high D-dimer after stopping anticoagulants in those with pulmonary embolism and obstructive sleep apnoea compared with PE without obstructive sleep apnoea (35.4% versus 19.0%, p=0.003). Apnoea-hypopnoea index was independently associated with high D-dimer.Pulmonary embolism patients with obstructive sleep apnoea had higher rates of elevated D-dimer levels after anticoagulation discontinuation for pulmonary embolism than in patients without obstructive sleep apnoea and, therefore, higher procoagulant state that might increase the risk of pulmonary embolism recurrence. Copyright ©ERS 2015.
Siqueira, Flavio Meirelles; Monsignore, Lucas Moretti; Rosa-E-Silva, Julio Cesar; Poli-Neto, Omero Benedicto; Castro-Afonso, Luis Henrique de; Nakiri, Guilherme Seizem; Muglia, Valdair Francisco; Abud, Daniel Giansante
2016-12-01
To evaluate the clinical response and success rate after periuterine varices embolization in patients with chronic pelvic pain secondary to pelvic congestion syndrome and to report the safety of endovascular treatment and its rate of complications. Retrospective cohort of patients undergoing endovascular treatment of pelvic congestion syndrome in our department from January 2012 to November 2015. Data were analyzed based on patient background, imaging findings, embolized veins, rate of complications, and clinical response as indicated by the visual analog pain scale. We performed periuterine varices embolization in 22 patients during the study, four of which required a second embolization. Seventeen patients reported a reduction in pelvic pain after the first embolization and three patients reported a reduction in pelvic pain after the second embolization. Minor complications were observed in our patients, such as postural hypotension, postoperative pain, and venous perforation during the procedure, without clinical repercussion. Periuterine varices embolization in patients with chronic pelvic pain secondary to pelvic congestion syndrome appears to be an effective and safe technique.
Overestimation of Susceptibility Vessel Sign: A Predictive Marker of Stroke Cause.
Zhang, Ruiting; Zhou, Ying; Liu, Chang; Zhang, Meixia; Yan, Shenqiang; Liebeskind, David S; Lou, Min
2017-07-01
The extent of blooming artifact may reflect the amount of paramagnetic material. We thus assessed the overestimation ratio of susceptibility vessel sign (SVS) on susceptibility-weighted imaging, defined as the extent of SVS width beyond the lumen and examined its value for predicting the stroke cause in acute ischemic stroke patients. We included consecutive acute ischemic stroke patients with proximal large artery occlusion who underwent both susceptibility-weighted imaging and time-of-flight magnetic resonance angiography within 8 hours poststroke onset. We calculated the length, width, and overestimation ratio of SVS on susceptibility-weighted imaging and then investigated their values for predicting the stroke cause, respectively. One-hundred eleven consecutive patients (72 female; mean age, 66.6±13.4 years) were enrolled, among whom 39 (35.1%) were diagnosed with cardiogenic embolism, 43 (38.7%) with large artery atherosclerosis, and 29 (26.1%) with undetermined cause. The presence, length, width, and overestimation ratio of SVS were all independently associated with the cause of cardiogenic embolism after adjusting for baseline National Institute of Health Stroke Scale and infarct volume. After excluded patients with undetermined cause, the sensitivity and specificity of overestimation ratio of SVS for cardiogenic embolism were 0.971 and 0.913; for the length of SVS, they were 0.629 and 0.739; for the width of SVS, they were 0.829 and 0.826, respectively. The overestimation ratio of SVS can predict cardiogenic embolism, with both high sensitivity and specificity, which can be helpful for the management of acute ischemic stroke patients in hyperacute stage. © 2017 American Heart Association, Inc.
Nevzati, Edin; Rey, Jeannine; Coluccia, Daniel; D'Alonzo, Donato; Grüter, Basil; Remonda, Luca; Fandino, Javier; Marbacher, Serge
2017-10-01
The steady progess in the armamentarium of techniques available for endovascular treatment of intracranial aneurysms requires affordable and reproducable experimental animal models to test novel embolization materials such as stents and flow diverters. The aim of the present project was to design a safe, fast, and standardized surgical technique for stent assisted embolization of saccular aneurysms in a rat animal model. Saccular aneurysms were created from an arterial graft from the descending aorta.The aneurysms were microsurgically transplanted through end-to-side anastomosis to the infrarenal abdominal aorta of a syngenic male Wistar rat weighing >500 g. Following aneurysm anastomosis, aneurysm embolization was performed using balloon expandable magnesium stents (2.5 mm x 6 mm). The stent system was retrograde introduced from the lower abdominal aorta using a modified Seldinger technique. Following a pilot series of 6 animals, a total of 67 rats were operated according to established standard operating procedures. Mean surgery time, mean anastomosis time, and mean suturing time of the artery puncture site were 167 ± 22 min, 26 ± 6 min and 11 ± 5 min, respectively. The mortality rate was 6% (n=4). The morbidity rate was 7.5% (n=5), and in-stent thrombosis was found in 4 cases (n=2 early, n=2 late in stent thrombosis). The results demonstrate the feasibility of standardized stent occlusion of saccular sidewall aneurysms in rats - with low rates of morbidity and mortality. This stent embolization procedure combines the opportunity to study novel concepts of stent or flow diverter based devices as well as the molecular aspects of healing.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ahmed, Osman, E-mail: osman1423@gmail.com; Patel, Mikin V.; Masrani, Abdulrahman
PurposeTo report hepatic arterial-related complications encountered during planning and treatment angiograms for radioembolization and understand any potential-associated risk factors.Materials and Methods518 mapping or treatment angiograms for 180 patients with primary or metastatic disease to the liver treated by Yttrium-90 radioembolization between 2/2010 and 12/2015 were retrospectively reviewed. Intra-procedural complications were recorded per SIR guidelines. Patient demographics, indication for treatment, prior exposure to chemotherapeutic agents, operator experience, and disease burden were reviewed. Technical variables including type of radioembolic (glass vs. resin microspheres), indication for angiography (mapping vs. treatment), variant anatomy, and attempts at coil embolization were also assessed.ResultsThirteen (13/518, 2.5%) arterial-relatedmore » complications occurred in 13 patients. All but two complications resulted during transcatheter coil embolization to prevent non-target embolization. Complications included coil migration (n = 6), arterial dissection (n = 2), focal vessel perforation (n = 2), arterial thrombus (n = 2), and vasospasm prohibiting further arterial sub-selection (n = 1). Transarterial coiling was identified as a significant risk factor of complications on both univariate and multivariate regression analysis (odds ratio 7.8, P = 0.004). Usage of resin microspheres was also a significant risk factor (odds ratio 9.5, P = 0.042). No other technical parameters or pre-procedural variables were significant after adjusting for confounding on multivariate analysis (P > 0.05).ConclusionIntra-procedural hepatic arterial complications encountered during radioembolization were infrequent but occurred mainly during coil embolization to prevent non-target delivery to extra-hepatic arteries.« less
Histopathologic and Immunohistochemical Sequelae of Bariatric Embolization in a Porcine Model
Paxton, Ben E.; Alley, Christopher L.; Crow, Jennifer H.; Burchette, James; Weiss, Clifford R.; Kraitchman, Dara L.; Arepally, Aravind; Kim, Charles Y.
2014-01-01
Purpose To evaluate the histopathologic sequelae of bariatric embolization on the gastric mucosa and to correlate with immunohistochemical evaluation of the gastric fundus, antrum, and duodenum. Materials and Methods This study was performed on 12 swine stomach and duodenum specimens after necropsy. Of the 12 swine, 6 had previously undergone bariatric embolization of the gastric fundus, and the 6 control swine had undergone a sham procedure with saline. Gross pathologic, histopathologic, and immunohistochemical examinations of the stomach and duodenum were performed. Specifically, mucosal integrity, fibrosis, ghrelin-expressing cells, and gastrin-expressing cells were assessed. Results Gross and histopathologic evaluation of treatment animals showed healing or healed mucosal ulcers in 50% of animals, with gastritis in 100% of treatment animals and in five of six control animals. The ghrelin-immunoreactive mean cell density was significantly lower in the gastric fundus in the treated animals compared with control animals (15.3 vs 22.0, P < .01) but similar in the gastric antrum (9.3 vs 14.3, P = .08) and duodenum (8.5 vs 8.6, P = .89). The gastrin-expressing cell density was significantly lower in the antrum of treated animals compared with control animals (82.2 vs 126.4, P = .03). A trend toward increased fibrosis was suggested in the gastric fundus of treated animals compared with controls (P = .07). Conclusions Bariatric embolization resulted in a significant reduction in ghrelin-expressing cells in the gastric fundus without evidence of upregulation of ghrelin-expressing cells in the duodenum. Healing ulcerations in half of treated animals underscores the need for additional refinement of this procedure. PMID:24462005
Zbroszczyk, Miłosz; Przybyłko, Nikodem; Hofman, Mariusz; Jamróz, Tomasz; Baron, Jan; Bażowski, Piotr; Kwiek, Stanisław
2016-01-01
Objective We report our experience with endovascular coiling of anterior communicating artery aneurysms with special consideration of angiographic and clinical outcomes and periprocedural complications. Materials and methods The analysis included treatment results of 28 patients with ruptured and unruptured aneurysms. The aneurysm size ranged from 1.8 to 9.8 mm (mean 5.2, SD 1.7). Clinical examinations with the use of modified Rankin Score and angiographic outcomes were evaluated initially post-embolization and at a minimum follow-up of six months. Results Initial post-treatment complete and near-complete aneurysm occlusion was achieved in 27 (96%) cases and incomplete occlusion in one (4%) case. Imaging follow-up, performed in 15 (53.6%) patients, showed no change in the degree of occlusion in 11 (73%), coil compaction in one (7%) and progressive occlusion in three (20%) patients. Three (20%) patients underwent a second coil embolization. The procedure-related severe morbidity and mortality rate was 6.4% (2/31). Coil prolapse was present in one (3.2%) case and intraprocedural aneurysm rupture in three (9.6%) cases. The clinical follow-up evaluation achieved in 19 (67.9%) patients showed no change in 17 (89.5%) patients and improvement in two (10.5%) patients. Conclusions Although the efficacy of coil embolization of anterior communicating artery aneurysms is unquestionable and the procedure-related complications are acceptable, they should not be neglected. Further investigations are needed to better understand protective factors, as well as to establish unequivocally appropriate management strategy of these complications. PMID:27531863
Kehoe, Sharon; Tremblay, Marie-Laurence; Coughlan, Aisling; Towler, Mark R.; Rainey, Jan K.; Abraham, Robert J.; Boyd, Daniel
2013-01-01
Experimental embolic particles based on a novel zinc-silicate glass system have been biologically evaluated for potential consideration in transcatheter arterial embolization procedures. In addition to controlling the cytotoxicity and haemocompatibility for such embolic particles, its glass structure may mediate specific responses via dissolution in the physiological environment. In a 120 h in-vitro dissolution study, ion release levels for silicon (Si4+), sodium (Na+), calcium (Ca2+), zinc (Zn2+), titanium (Ti4+), lanthanum (La3+), strontium (Sr2+), and magnesium (Mg2+), were found to range from 0.04 to 5.41 ppm, 0.27–2.28 ppm, 2.32–8.47 ppm, 0.16–0.20 ppm, 0.12–2.15 ppm, 0.16–0.49 ppm and 0.01–0.12 ppm, respectively for the series of glass compositions evaluated. Initial release of Zn2+ (1.93–10.40 ppm) was only evident after 120 h. All compositions showed levels of cell viabilities ranging from 61.31 ± 4.33% to 153.7 ± 1.25% at 25%–100% serial extract dilutions. The conformational state of fibrinogen, known to induce thrombi, indicated that no changes were induced with respect of the materials dissolution by-products. Furthermore, the best-in-class experimental composition showed equivalency to contour PVA in terms of inducing platelet adhesion. The data generated here provides requisite evidence to continue to in-vivo pre-clinical evaluation using the best-in-class experimental composition evaluated. PMID:24956083
Therapy-resistant nephrolithiasis following renal artery coil embolization
2013-01-01
Background Transcatheter renal artery embolization is an effective and minimally invasive treatment option for acute renal bleeding. Early post-interventional complications include groin hematoma, incomplete embolization, coil misplacement and coil migration. Late complications are rare and mostly related to coil migration. Case presentation A 22-year-old woman with a history of recurrent stone disease and a lumbal meningomyelocele underwent bilateral open pyelolithotomy for bilateral staghorn calculi. Post-operatively, acute hemorrhage of the left kidney occurred and selective arterial coil embolization of a lower pole interlobular renal artery was performed twice. Four years after this intervention the patient presented with a new 15.4 mm stone in the lower calyx of the left kidney. After two extracorporeal shock wave lithotripsy treatments disintegration of the stone was not detectable. Therefore, flexible ureterorenoscopy was performed and revealed that the stone was adherent to a partially intraluminal metal coil in the lower renal calyx. The intracalyceal part of the coil and the adherent stone were successfully removed using the holmium laser. Conclusion Therapy-resistant nephrolithiasis was caused by a migrated metal coil, which was placed four years earlier for the treatment of acute post-operative renal bleeding. Renal coils in close vicinity to the renal pelvis can migrate into the collecting system and trigger renal stone formation. Extracorporeal shock wave lithotripsy seems to be inefficient for these composite stones. Identification of these rare stones is possible during retrograde intrarenal surgery. It also enables immediate stone disintegration and removal of the stone fragments and the intraluminal coil material. PMID:23758632
Rizzi, Marco; Ravasio, Veronica; Carobbio, Alessandra; Mattucci, Irene; Crapis, Massimo; Stellini, Roberto; Pasticci, Maria Bruna; Chinello, Pierangelo; Falcone, Marco; Grossi, Paolo; Barbaro, Francesco; Pan, Angelo; Viale, Pierluigi; Durante-Mangoni, Emanuele
2014-04-29
Embolic events are a major cause of morbidity and mortality in patients with infective endocarditis. We analyzed the database of the prospective cohort study SEI in order to identify factors associated with the occurrence of embolic events and to develop a scoring system for the assessment of the risk of embolism. We retrospectively analyzed 1456 episodes of infective endocarditis from the multicenter study SEI. Predictors of embolism were identified. Risk factors identified at multivariate analysis as predictive of embolism in left-sided endocarditis, were used for the development of a risk score: 1 point was assigned to each risk factor (total risk score range: minimum 0 points; maximum 2 points). Three categories were defined by the score: low (0 points), intermediate (1 point), or high risk (2 points); the probability of embolic events per risk category was calculated for each day on treatment (day 0 through day 30). There were 499 episodes of infective endocarditis (34%) that were complicated by ≥ 1 embolic event. Most embolic events occurred early in the clinical course (first week of therapy: 15.5 episodes per 1000 patient days; second week: 3.7 episodes per 1000 patient days). In the total cohort, the factors associated with the occurrence of embolism at multivariate analysis were prosthetic valve localization (odds ratio, 1.84), right-sided endocarditis (odds ratio, 3.93), Staphylococcus aureus etiology (odds ratio, 2.23) and vegetation size ≥ 13 mm (odds ratio, 1.86). In left-sided endocarditis, Staphylococcus aureus etiology (odds ratio, 2.1) and vegetation size ≥ 13 mm (odds ratio, 2.1) were independently associated with embolic events; the 30-day cumulative incidence of embolism varied with risk score category (low risk, 12%; intermediate risk, 25%; high risk, 38%; p < 0.001). Staphylococcus aureus etiology and vegetation size are associated with an increased risk of embolism. In left-sided endocarditis, a simple scoring system, which combines etiology and vegetation size with time on antimicrobials, might contribute to a better assessment of the risk of embolism, and to a more individualized analysis of indications and contraindications for early surgery.
Mohkam, Kayvan; Rode, Agnès; Darnis, Benjamin; Manichon, Anne-Frédérique; Boussel, Loïc; Ducerf, Christian; Merle, Philippe; Lesurtel, Mickaël; Mabrut, Jean-Yves
2018-05-09
The impact of portal hemodynamic variations after portal vein embolization on liver regeneration remains unknown. We studied the correlation between the parameters of hepatic venous pressure measured before and after portal vein embolization and future hypertrophy of the liver remnant after portal vein embolization. Between 2014 and 2017, we reviewed patients who were eligible for major hepatectomy and who had portal vein embolization. Patients had undergone simultaneous measurement of portal venous pressure and hepatic venous pressure gradient before and after portal vein embolization by direct puncture of portal vein and inferior vena cava. We assessed these parameters to predict future liver remnant hypertrophy. Twenty-six patients were included. After portal vein embolization, median portal venous pressure (range) increased from 15 (9-24) to 19 (10-27) mm Hg and hepatic venous pressure gradient increased from 5 (0-12) to 8 (0-14) mm Hg. Median future liver remnant volume (range) was 513 (299-933) mL before portal vein embolization versus 724 (499-1279) mL 3 weeks after portal vein embolization, representing a 35% (7.4-83.6) median hypertrophy. Post-portal vein embolization hepatic venous pressure gradient was the most accurate parameter to predict failure of future liver remnant to reach a 30% hypertrophy (c-statistic: 0.882 [95% CI: 0.727-1.000], P < 0.001). A cut-off value of post-portal vein embolization hepatic venous pressure gradient of 8 mm Hg showed a sensitivity of 91% (95% CI: 57%-99%), specificity of 80% (95% CI: 52%-96%), positive predictive value of 77% (95% CI: 46%-95%) and negative predictive value of 92.3% (95% CI: 64.0%-99.8%). On multivariate analysis, post-portal vein embolization hepatic venous pressure gradient and previous chemotherapy were identified as predictors of impaired future liver remnant hypertrophy. Post-portal vein embolization hepatic venous pressure gradient is a simple and reproducible tool which accurately predicts future liver remnant hypertrophy after portal vein embolization and allows early detection of patients who may benefit from more aggressive procedures inducing future liver remnant hypertrophy. (Surgery 2018;143:1-2.). Copyright © 2018 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Patel, Shreyas R., E-mail: Shrey000@gmail.com; Vachhani, Prasann; Moeslein, Fred
Solitary fibrous tumor of the pleura (SFTP) is a rare intrathoracic neoplasm, often giant in size and highly vascular, which can make surgical resection very challenging. Preoperative percutaneous embolization before surgical removal can significantly reduce the risk of uncontrollable intraoperative hemorrhage. However, a rare potential life threatening complication could result from embolization of SFTP and must be taken into consideration. This report describes a 69-year-old female with a large right thoracic SFTP, who underwent preoperative angiography and embolization and developed diffuse embolic brain infarcts immediately after the administration of polyvinyl alcohol particles.
Fatal fat embolism syndrome in a case of isolated L1 vertebral fracture-dislocation.
Yamauchi, Koun; Fushimi, Kazunari; Ikeda, Tsuneko; Fukuta, Masashi
2013-11-01
Although fat embolism syndrome is a well-known complication of fractures of the long bones or pelvis, fat embolism syndrome occurring subsequent to fracture of the lumbar spine is rare. We report a fatal case of fat embolism syndrome characterized by fat and bone marrow embolism that occurred 36 h after an isolated fracture-dislocation of the L1 vertebra. A postmortem examination was performed and pathological finding demonstrated fat and bone marrow tissue which were disseminated in the bilateral pulmonary arteries. We need to be aware of the possibility of fat embolism syndrome as a complication of spinal fractures, including isolated vertebral body fractures.
Systemic fat embolism and the patent foramen ovale--a prospective autopsy study.
Nikolić, Slobodan; Zivković, Vladimir; Babić, Dragan; Djonić, Danijela; Djurić, Marija
2012-05-01
A fat embolism is a known and common complication of blunt force injuries, especially pelvic and long bones fractures. The aim of this study was to determine the importance of a patent foramen ovale (PFO) in developing systemic fat embolism (SFE) and eventually fat embolism syndrome (FES) in patients suffering from orthopaedic blunt injuries and consequent lung fat embolism. The sample was divided: 32 subjects with a sealed foramen ovale (SFO), and 20 subjects with a PFO. In our sample, there was no difference in either the incidence of renal fat embolism in subjects with PFO compared to those with SFO (Fisher's exact test 0.228, p=0.154) or in the grade of renal fat embolism (Pearson Chi-square 2.728, p=0.435). However, there was a statistically significant correlation between the grade of lung fat embolism and the number of fractured bones for the whole sample (Spearman's rho 0.271, p=0.052), but no correlation between the grade of lung fat embolism and the ISS or NISS (Pearson correlation 0.048, p=0.736, and 0.108, p=0.445, respectively). In our study, the presence of fat emboli in the kidney, i.e. SFE, could effectively be predicted by the grade of lung fat embolism (the moderate and slight grades of lung fat embolism were better predictors than the massive one: logistic regression - Wald. Coeff.=11.446, p=0.003, Wald. Coeff.=10.553, p=0.001, and Wald. Coeff.=4.128, p=0.042), and less effectively by presence of PFO (Wald. Coeff.=2.850, p=0.091). This study pointed out that lung and SFE are not pure biomechanical events, so the role of a PFO is not crucial in developing a lung fat embolism into a systemic embolism: the fat embolism is more of a biochemical and pathophsyiological event, than a biomechanical one. The appearance of a patent foramen ovale associated with a systemic fat embolism should be less emphasised: maybe arteriovenous shunts and anastomosis between the functional and nutritive, i.e. systemic circulation of lungs play a more important role in developing a SFE than a PFO. Copyright © 2010 Elsevier Ltd. All rights reserved.
Value of Round Ligament Artery Embolization in the Management of Postpartum Hemorrhage.
Leleup, Grégoire; Fohlen, Audrey; Dohan, Anthony; Bryan-Rest, Lara; Le Pennec, Vincent; Limot, Olivier; Le Dref, Olivier; Soyer, Philippe; Pelage, Jean-Pierre
2017-05-01
To evaluate the feasibility and efficacy of embolization of the round ligament arteries in the management of postpartum hemorrhage. Eleven women (mean age, 31 y) underwent round ligament artery because of persistent or recurrent hemorrhage after initial uterine or internal iliac artery embolization. A total of 16 round ligament arteries were embolized. The round ligament artery arose from the inferior epigastric artery in 11 cases (69%) and directly from the external iliac artery in 5 (31%). Embolization was performed with calibrated microspheres in 7 women (63%) and gelatin sponge pledgets in 4 (37%). Coils were used in addition to gelatin sponge pledgets in 3 patients. Hemostasis was achieved in 10 patients (91%), and 1 required additional conservative surgery. The mean hemoglobin level before embolization was 7.2 g/dL ± 1 and increased significantly on day 1 after embolization (10.3 g/dL ± 1.0; P < .05). No procedure-related complication was reported. The mean hospital stay was 5.6 days ± 2. Two patients had further pregnancies 13 and 14 months after embolization. Selective embolization of the round ligament artery is a safe and effective treatment for obstetric hemorrhage. It should be considered in cases of persistent or recurrent bleeding after initial uterine or internal iliac artery embolization. Copyright © 2017 SIR. Published by Elsevier Inc. All rights reserved.
Lutz, J; Holtmannspötter, M; Flatz, W; Meier-Bender, A; Berghaus, A; Brückmann, H; Zengel, P
2016-12-01
Juvenile nasopharyngeal angiofibroma (JNA) is a rare benign neoplasm that occurs almost exclusively in the nasopharynx of adolescent male individuals. We performed a retrospective study to determine the efficacy and safety of preoperative embolization and the surgical outcome in patients with JNA in a single-center institution. Fifteen cases undergoing embolization and surgical treatment between April 2003 and February 2013 were evaluated retrospectively. The demographic data, clinical presentation, and treatment were reviewed including the kind of preoperative embolization and different surgical approaches performed. The parameters investigated were the amount of blood loss, the tumor stage, and the rates of recurrence. Subsequently, a comparison was made between patients who had undergone Onyx ® embolization versus those who had been embolized with the standard approach. In these 15 patients (mean age, 15 years), a total of 27 surgical procedures were performed. One patient was at stage Ia, two were at stage Ib, two were at stage IIa, six were at stage IIb, one was at stage IIc, and three were at stage IIIa based on the Radkowsky classification. All patients underwent preoperative embolization and subsequent surgery. The surgical approach and the embolization technique varied and evolved during time. The embolization procedure decreased the intraoperative blood loss to a minimum of 250 ml, and with the advent of intratumoral embolization, the rate of recurrence diminished. Preoperative Onyx ® embolization facilitates the shift in the treatment to endoscopic excision in selected patients, which reduces recurrence rates and overall morbidity.
Poujade, Olivier; Ceccaldi, Pierre François; Davitian, Carine; Amate, Pascale; Chatel, Paul; Khater, Carine; Aflak, Nizar; Vilgrain, Valérie; Luton, Dominique
2013-10-01
Uterine necrosis is one of the rarest complications following pelvic arterial embolization for postpartum hemorrhage (PPH). With the increasing incidence of cesarean section and abnormal placental localization (placenta previa) or placental invasion (placenta accreta/increta/percreta), more and more cases of uterine necrosis after embolization are being diagnosed and reported. Pelvic computed tomography or magnetic resonance imaging provides high diagnostic accuracy, and surgical management includes hysterectomy. We performed a Medline database query following the first description of uterine necrosis after pelvic embolization (between January 1985 and January 2013). Medical subheading search words were the following: "uterine necrosis"; "embolization"; "postpartum hemorrhage". Seventeen citations reporting at least one case of uterine necrosis after pelvic embolization for PPH were included, with a total of 19 cases. This literature review discusses the etiopathogenesis, clinical and therapeutic aspects of uterine necrosis following pelvic arterial embolization, and guidelines are detailed. The mean time interval between pelvic embolization and diagnosis of uterine necrosis was 21 days (range 9-730). The main symptoms of uterine necrosis were fever, abdominal pain, menorrhagia and leukorrhea. Surgical management included total hysterectomy (n=15, 78%) or subtotal hysterectomy (n=2, 10%) and partial cystectomy with excision of the necrotic portion in three cases of associated bladder necrosis (15%). Uterine necrosis was partial in four cases (21%). Regarding the pathophysiology, four factors may be involved in uterine necrosis: the size and nature of the embolizing agent, the presence of the anastomotic vascular system and the embolization technique itself with the use of free flow embolization. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
Devascularization of Head and Neck Paragangliomas by Direct Percutaneous Embolization
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ozyer, Umut, E-mail: umut_ozyer@yahoo.com; Harman, Ali; Yildirim, Erkan
2010-10-15
Preoperative transarterial embolization of head and neck paragangliomas using particulate agents has proven beneficial for decreasing intraoperative blood loss. However, the procedure is often incomplete owing to extensive vascular structure and arteriovenous shunts. We report our experience with embolization of these lesions by means of direct puncture and intratumoral injection of n-butyl cyanoacrylate (NBCA) or Onyx. Ten patients aged 32-82 years who were referred for preoperative embolization of seven carotid body tumors and three jugular paragangliomas were retrospectively analyzed. Intratumoral injections were primarily performed in four cases with multiple small-caliber arterial feeders and adjunctive to transarterial embolization in six casesmore » with incomplete devascularization. Punctures were performed under ultrasound and injections were performed under roadmap fluoroscopic guidance. Detailed angiographies were performed before and after embolization procedures. Control angiograms showed complete or near-complete devascularization in all tumors. Three tumors with multiple small-caliber arterial feeders were treated with primary NBCA injections. One tumor necessitated transarterial embolization after primary injection of Onyx. Six tumors showed regional vascularization from the vasa vasorum or small-caliber branches of the external carotid artery following the transarterial approach. These regions were embolized with NBCA injections. No technical or clinical complications related to embolization procedures occurred. All except one of the tumors were surgically removed following embolization. In conclusion, preoperative devascularization with percutaneous direct injection of NBCA or Onyx is feasible, safe, and effective in head and neck paragangliomas with multiple small-caliber arterial feeders and in cases of incomplete devascularization following transarterial embolization.« less
ONYX versus n-BCA for embolization of cranial dural arteriovenous fistulas.
Rabinov, James David; Yoo, Albert J; Ogilvy, Christopher S; Carter, Bob S; Hirsch, Joshua A
2013-07-01
To evaluate the efficacy of n-butyl-2-cyanoacrylate (Trufill n-BCA) versus ethylene vinyl alcohol copolymer (ONYX) for the embolization of cranial dural arteriovenous fistulas (DAVF). Fifty-three consecutive patients with cranial dural AVF were treated with liquid embolic agents from November, 2003 to November, 2008. These 53 patients had 56 lesions treated with arterial embolization. Patients embolized to completion underwent follow-up angiography at 3 months to assess for durable occlusion. Twenty-one lesions were treated with n-BCA. Seven patients treated with n-BCA had initial angiographic occlusion of their DAVF, which were durable at 3 months. Six patients had adjunctive treatment with coils and/or polyvinyl alcohol particles, but none of these were occluded by endovascular treatment alone. Eleven patients underwent post-embolization surgery for closure of their DAVF. There was one death related to intractable status epilepticus at presentation. One patient developed a major stroke from venous sinus thrombosis after embolization. Thirty-five lesions were treated with ONYX in 34 patients. Twenty-nine patients treated with ONYX had initial angiographic occlusion of their DAVF by embolization alone. One patient had recurrence at 3 months and was re-treated out of 27 total follow-ups. Four patients underwent post-embolization surgical obliteration of their lesions. No deaths or major strokes occurred in this cohort. Initial angiographic occlusion (p=0.0004) and durable angiographic occlusion (p=0.0018) rates for embolization of cranial DAVF show a statistically significant higher efficacy with ONYX compared with n-BCA. Patients embolized with ONYX underwent surgery less frequently compared with those treated with n-BCA (p=0.0015).
Embolization Therapy for Traumatic Splenic Lacerations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dasgupta, Niloy; Matsumoto, Alan H., E-mail: ahm4d@virginia.edu; Arslan, Bulent
Purpose: This study was designed to evaluate the clinical success, complications, and transfusion requirements based on the location of and agents used for splenic artery embolization in patients with splenic trauma. Methods: A retrospective study was performed of patients with splenic trauma who underwent angiography and embolization from September 2000 to January 2010 at a level I trauma center. Electronic medical records were reviewed for demographics, imaging data, technical aspects of the procedure, and clinical outcomes. Results: Fifty patients were identified (34 men and 16 women), with an average age of 48 (range, 16-80) years. Extravasation was seen on initialmore » angiography in 27 (54%) and was absent in 23 (46%). All 27 patients with extravasation were embolized, and 18 of 23 (78.2%) without extravasation were embolized empirically. Primary clinical success was similar (>75%) across all embolization locations, embolic agents, and grades of laceration treated. Of 45 patients treated, 9 patients (20%) were embolized in the main splenic artery, 34 (75.6%) in the splenic hilum, and 2 (4.4%) were embolized in both locations. Partial splenic infarctions developed in 47.3% treated in the splenic hilum compared with 12.5% treated in the main splenic artery. There were four (8.9%) mortalities: two occurred in patients with multiple critical injuries and two from nonbleeding etiologies. Conclusions: Embolization of traumatic splenic artery injuries is safe and effective, regardless of the location of treatment. Embolization in splenic hilar branches may have a higher incidence of infarction. The grade of laceration and agents used for embolotherapy did not impact the outcomes.« less
21 CFR 868.2025 - Ultrasonic air embolism monitor.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Ultrasonic air embolism monitor. 868.2025 Section... (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Monitoring Devices § 868.2025 Ultrasonic air embolism monitor. (a) Identification. An ultrasonic air embolism monitor is a device used to detect air bubbles in...
21 CFR 868.2025 - Ultrasonic air embolism monitor.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Ultrasonic air embolism monitor. 868.2025 Section... (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Monitoring Devices § 868.2025 Ultrasonic air embolism monitor. (a) Identification. An ultrasonic air embolism monitor is a device used to detect air bubbles in...
21 CFR 868.2025 - Ultrasonic air embolism monitor.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ultrasonic air embolism monitor. 868.2025 Section... (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Monitoring Devices § 868.2025 Ultrasonic air embolism monitor. (a) Identification. An ultrasonic air embolism monitor is a device used to detect air bubbles in...
Coil Embolization for Intracranial Aneurysms
2006-01-01
Executive Summary Objective To determine the effectiveness and cost-effectiveness of coil embolization compared with surgical clipping to treat intracranial aneurysms. The Technology Endovascular coil embolization is a percutaneous approach to treat an intracranial aneurysm from within the blood vessel without the need of a craniotomy. In this procedure, a microcatheter is inserted into the femoral artery near the groin and navigated to the site of the aneurysm. Small helical platinum coils are deployed through the microcatheter to fill the aneurysm, and prevent it from further expansion and rupture. Health Canada has approved numerous types of coils and coil delivery systems to treat intracranial aneurysms. The most favoured are controlled detachable coils. Coil embolization may be used with other adjunct endovascular devices such as stents and balloons. Background Intracranial Aneurysms Intracranial aneurysms are the dilation or ballooning of part of a blood vessel in the brain. Intracranial aneurysms range in size from small (<12 mm in diameter) to large (12–25 mm), and to giant (>25 mm). There are 3 main types of aneurysms. Fusiform aneurysms involve the entire circumference of the artery; saccular aneurysms have outpouchings; and dissecting aneurysms have tears in the arterial wall. Berry aneurysms are saccular aneurysms with well-defined necks. Intracranial aneurysms may occur in any blood vessel of the brain; however, they are most commonly found at the branch points of large arteries that form the circle of Willis at the base of the brain. In 85% to 95% of patients, they are found in the anterior circulation. Aneurysms in the posterior circulation are less frequent, and are more difficult to treat surgically due to inaccessibility. Most intracranial aneurysms are small and asymptomatic. Large aneurysms may have a mass effect, causing compression on the brain and cranial nerves and neurological deficits. When an intracranial aneurysm ruptures and bleeds, resulting in a subarachnoid hemorrhage (SAH), the mortality rate can be 40% to 50%, with severe morbidity of 10% to 20%. The reported overall risk of rupture is 1.9% per year and is higher for women, cigarette smokers, and cocaine users, and in aneurysms that are symptomatic, greater than 10 mm in diameter, or located in the posterior circulation. If left untreated, there is a considerable risk of repeat hemorrhage in a ruptured aneurysm that results in increased mortality. In Ontario, intracranial aneurysms occur in about 1% to 4% of the population, and the annual incidence of SAH is about 10 cases per 100,000 people. In 2004-2005, about 660 intracranial aneurysm repairs were performed in Ontario. Treatment of Intracranial Aneurysms Treatment of an unruptured aneurysm attempts to prevent the aneurysm from rupturing. The treatment of a ruptured intracranial aneurysm aims to prevent further hemorrhage. There are 3 approaches to treating an intracranial aneurysm. Small, asymptomatic aneurysms less than 10 mm in diameter may be monitored without any intervention other than treatment for underlying risk factors such as hypertension. Open surgical clipping, involves craniotomy, brain retraction, and placement of a silver clip across the neck of the aneurysm while a patient is under general anesthesia. This procedure is associated with surgical risks and neurological deficits. Endovascular coil embolization, introduced in the 1990s, is the health technology under review. Literature Review Methods The Medical Advisory Secretariat searched the International Health Technology Assessment (INAHTA) Database and the Cochrane Database of Systematic Reviews to identify relevant systematic reviews. OVID Medline, Medline In-Process and Other Non-Indexed Citations, and Embase were searched for English-language journal articles that reported primary data on the effectiveness or cost-effectiveness of treatments for intracranial aneurysms, obtained in a clinical setting or analyses of primary data maintained in registers or institutional databases. Internet searches of Medscape and manufacturers’ databases were conducted to identify product information and recent reports on trials that were unpublished but that were presented at international conferences. Four systematic reviews, 3 reports on 2 randomized controlled trials comparing coil embolization with surgical clipping of ruptured aneurysms, 30 observational studies, and 3 economic analysis reports were included in this review. Results Safety and Effectiveness Coil embolization appears to be a safe procedure. Complications associated with coil embolization ranged from 8.6% to 18.6% with a median of about 10.6%. Observational studies showed that coil embolization is associated with lower complication rates than surgical clipping (permanent complication 3-7% versus 10.9%; overall 23% versus 46% respectively, p=0.009). Common complications of coil embolization are thrombo-embolic events (2.5%–14.5%), perforation of aneurysm (2.3%–4.7%), parent artery obstruction (2%–3%), collapsed coils (8%), coil malposition (14.6%), and coil migration (0.5%–3%). Randomized controlled trials showed that for ruptured intracranial aneurysms with SAH, suitable for both coil embolization and surgical clipping (mostly saccular aneurysms <10 mm in diameter located in the anterior circulation) in people with good clinical condition:Coil embolization resulted in a statistically significant 23.9% relative risk reduction and 7% absolute risk reduction in the composite rate of death and dependency compared to surgical clipping (modified Rankin score 3–6) at 1-year. The advantage of coil embolization over surgical clipping varies widely with aneurysm location, but endovascular treatment seems beneficial for all sites. There were less deaths in the first 7 years following coil embolization compared to surgical clipping (10.8% vs 13.7%). This survival benefit seemed to be consistent over time, and was statistically significant (log-rank p= 0.03). Coil embolization is associated with less frequent MRI-detected superficial brain deficits and ischemic lesions at 1-year. The 1- year rebleeding rate was 2.4% after coil embolization and 1% for surgical clipping. Confirmed rebleeding from the repaired aneurysm after the first year and up to year eight was low and not significantly different between coil embolization and surgical clipping (7 patients for coil embolization vs 2 patients for surgical clipping, log-rank p=0.22). Observational studies showed that patients with SAH and good clinical grade had better 6-month outcomes and lower risk of symptomatic cerebral vasospasm after coil embolization compared to surgical clipping. For unruptured intracranial aneurysms, there were no randomized controlled trials that compared coil embolization to surgical clipping. Large observational studies showed that: The risk of rupture in unruptured aneurysms less than 10 mm in diameter is about 0.05% per year for patients with no pervious history of SAH from another aneurysm. The risk of rupture increases with history of SAH and as the diameter of the aneurysm reaches 10 mm or more. Coil embolization reduced the composite rate of in hospital deaths and discharge to long-term or short-term care facilities compared to surgical clipping (Odds Ratio 2.2, 95% CI 1.6–3.1, p<0.001). The improvement in discharge disposition was highest in people older than 65 years. In-hospital mortality rate following treatment of intracranial aneurysm ranged from 0.5% to 1.7% for coil embolization and from 2.1% to 3.5% for surgical clipping. The overall 1-year mortality rate was 3.1% for coil embolization and 2.3% for surgical clipping. One-year morbidity rate was 6.4% for coil embolization and 9.8% for surgical clipping. It is not clear whether these differences were statistically significant. Coil embolization is associated with shorter hospital stay compared to surgical clipping. For both ruptured and unruptured aneurysms, the outcome of coil embolization does not appear to be dependent on age, whereas surgical clipping has been shown to yield worse outcome for patients older than 64 years. Angiographic Efficiency and Recurrences The main drawback of coil embolization is its low angiographic efficiency. The percentage of complete aneurysm occlusion after coil embolization (27%–79%, median 55%) remains lower than that achieved with surgical clipping (82%–100%). However, about 90% of coiled aneurysms achieve near total occlusion or better. Incompletely coiled aneurysms have been shown to have higher aneurysm recurrence rates ranging from 7% to 39% for coil embolization compared to 2.9% for surgical clipping. Recurrence is defined as refilling of the neck, sac, or dome of a successfully treated aneurysm as shown on an angiogram. The long-term clinical significance of incomplete occlusion following coil embolization is unknown, but in one case series, 20% of patients had major recurrences, and 50% of these required further treatment. Long-Term Outcomes A large international randomized trial reported that the survival benefit from coil embolization was sustained for at least 7 years. The rebleeding rate between year 2 and year 8 following coil embolization was low and not significantly different from that of surgical clipping. However, high quality long-term angiographic evidence is lacking. Accordingly, there is uncertainty about long-term occlusion status, coil durability, and recurrence rates. While surgical clipping is associated with higher immediate procedural risks, its long-term effectiveness has been established. Indications and Contraindications Coil embolization offers treatment for people at increased risk for craniotomy, such as those over 65 years of age, with poor clinical status, or with comorbid conditions. The technology also makes it possible to treat surgical high-risk aneurysms. Not all aneurysms are suitable for coil embolization. Suitability depends on the size, anatomy, and location of the aneurysm. Aneurysms more than 10 mm in diameter or with an aneurysm neck greater than or equal to 4 mm are less likely to achieve total occlusion. They are also more prone to aneurysm recurrences and to complications such as coil compaction or parent vessel occlusion. Aneurysms with a dome to neck ratio of less than 1 have been shown to have lower obliteration rates and poorer outcome following coil embolization. Furthermore, aneurysms in the middle cerebral artery bifurcation are less suitable for coil embolization. For some aneurysms, treatment may require the use of both coil embolization and surgical clipping or adjunctive technologies, such as stents and balloons, to obtain optimal results. Diffusion Information from 3 countries indicates that coil embolization is a rapidly diffusing technology. For example, it accounted for about 40% of aneurysm treatments in the United Kingdom. In Ontario, coil embolization is an insured health service, with the same fee code and fee schedule as open surgical repair requiring craniotomy. Other costs associated with coil embolization are covered under hospitals’ global budgets. Utilization data showed that in 2004-2005, coil embolization accounted for about 38% (251 cases) of all intracranial aneurysm repairs in the province. With the 2005 publication of the positive long-term survival data from the International Subarachnoid Aneursym Trial, the pressure for diffusion will likely increase. Economic Analysis Recent economic studies show that treatment of unruptured intracranial aneurysms smaller than 10 mm in diameter in people with no previous history of SAH, either by coil embolization or surgical clipping, would not be effective or cost-effective. However, in patients with aneurysms that are greater than or equal to 10 mm or symptomatic, or in patients with a history of SAH, treatment appears to be cost-effective. In Ontario, the average device cost of coil embolization per case was estimated to be about $7,500 higher than surgical clipping. Assuming that the total number of intracranial aneurysm repairs in Ontario increases to 750 in the fiscal year of 2007, and assuming that up to 60% (450 cases) of these will be repaired by coil embolization, the difference in device costs for the 450 cases (including a 15% recurrence rate) would be approximately $3.8 million. This figure does not include capital costs (e.g. $3 million for an angiosuite), additional human resources required, or costs of follow-up. The increase in expenditures associated with coil embolization may be offset partially, by shorter operating room times and hospitalization stays for endovascular repair of unruptured aneurysms; however, the impact of these cost savings is probably not likely to be greater than 25% of the total outlay since the majority of cases involve ruptured aneurysms. Furthermore, the recent growth in aneurysm repair has predominantly been in the area of coil embolization presumably for patients for whom surgical clipping would not be advised; therefore, no offset of surgical clipping costs could be applied in such cases. For ruptured aneurysms, downstream cost savings from endovascular repair are likely to be minimal even though the savings for individual cases may be substantial due to lower perioperative complications for endovascular aneurysm repair. Guidelines The two Guidance documents issued by the National Institute of Clinical Excellence (UK) in 2005 support the use of coil embolization for both unruptured and ruptured (SAH) intracranial aneurysms, provided that procedures are in place for informed consent, audit, and clinical governance, and that the procedure is performed in specialist units with expertise in the endovascular treatment of intracranial aneurysms. Conclusion For people in good clinical condition following subarachnoid hemorrhage from an acute ruptured intracranial aneurysm suitable for either surgical clipping or endovascular repair, coil embolization results in improved independent survival in the first year and improved survival for up to seven years compared to surgical clipping. The rebleeding rate is low and not significantly different between the two procedures after the first year. However, there is uncertainty regarding the long-term occlusion status, durability of the stent graft, and long-term complications. For people with unruptured aneurysms, level 4 evidence suggests that coil embolization may be associated with comparable or less mortality and morbidity, shorter hospital stay, and less need for discharge to short-term rehabilitation facilities. The greatest benefit was observed in people over 65 years of age. In these patients, the decision regarding treatment needs to be based on the assessment of the risk of rupture against the risk of the procedure, as well as the morphology of the aneurysm. In people who require treatment for intracranial aneurysm, but for whom surgical clipping is too risky or not feasible, coil embolization provides survival benefits over surgical clipping, even though the outcomes may not be as favourable as in people in good clinical condition and with small aneurysms. The procedure may be considered under the following circumstances provided that the aneurysm is suitable for coil embolization: Patients in poor/unstable clinical or neurological state Patients at high risk for surgical repair (e.g. people>age 65 or with comorbidity), or Aneurysm(s) with poor accessibility or visibility for surgical treatment due to their location (e.g. ophthalmic or basilar tip aneurysms) Compared to small aneurysms with a narrow neck in the anterior circulation, large aneurysms (> 10 mm in diameter), aneurysms with a wide neck (>4mm in diameter), and aneurysms in the posterior circulation have lower occlusion rates and higher rate of hemorrhage when treated with coil embolization. The extent of aneurysm obliteration after coil embolization remains lower than that achieved with surgical clipping. Aneurysm recurrences after successful coiling may require repeat treatment with endovascular or surgical procedures. Experts caution that long-term angiographic outcomes of coil embolization are unknown at this time. Informed consent for and long-term follow-up after coil embolization are recommended. The decision to treat an intracranial aneurysm with surgical clipping or coil embolization needs to be made jointly by the neurosurgeon and neuro-intervention specialist, based on the clinical status of the patient, the size and morphology of the aneurysm, and the preference of the patient. The performance of endovascular coil embolization should take place in centres with expertise in both neurosurgery and endovascular neuro-interventions, with adequate treatment volumes to maintain good outcomes. Distribution of the technology should also take into account that patients with SAH should be treated as soon as possible with minimal disruption. PMID:23074479
Does prolonged semi-erection in prepubertal high flow priapism result in increased penile size?
Awwad, Ziad M
2005-03-01
High flow priapism is a rare pathology resulting mainly from trauma to the perineum leading to arterial-lacunar fistula. Management includes arterial embolization using absorbable material, as well as conservative approach. In this case, the effect of prolonged semi-erection in prepubertal high flow priapism on increased penile size is discussed.
Spontaneous Hemothorax in Neurofibromatosis Treated with Percutaneous Embolization
DOE Office of Scientific and Technical Information (OSTI.GOV)
Arai, Kazunori; Sanada, Junichiro; Kurozumi, Akiko
We evaluated the effectiveness of transcatheter arterial coil embolization therapy for the treatment of spontaneous hemothorax followed by aneurysm rupture in neurofibromatosis patients. Three patients were treated for massive hemothorax caused by arterial lesions associated with neurofibromatosis. Bleeding episodes were secondary to ascending cervical artery aneurysm and dissection of vertebral artery in 1 patient, and intercostal artery aneurysm with or without arteriovenous fistula in 2 patients. Patients were treated by transarterial coil embolization combined with chest drainage. In 1 patient, the ruptured ascending cervical artery aneurysm was well embolized but, shortly after the embolization, fatal hemorrhage induced by dissection ofmore » the vertebral artery occurred and the patient died. In the other 2 patients, the ruptured intercostal artery aneurysm was well embolized and they were successfully treated and discharged. Transcatheter arterial coil embolization therapy is an effective method for the treatment of spontaneous hemothorax followed by aneurysm rupture in neurofibromatosis patients.« less
Massive Pulmonary Calculi Embolism: A Novel Complication of Pneumatic Lithotripsy: A Case Report.
Zhang, Lin; Zhou, Yiwu
2015-07-01
Pneumatic lithotripsy is a minimally invasive technique mainly for the treatment of urinary staghorn stones. Previous literatures have reported some therapeutic complications during or after this procedure, but calculi embolism has not been mentioned before.We report here a fatal case of calculi-induced pulmonary embolism in an adult woman who underwent pneumatic lithotripsy. An autopsy did not reveal any evidence of pulmonary embolism. However, light microscopy revealed noticeable presence of calculi in pulmonary arterioles and capillaries, as evidenced by environmental scanning electron microscope and energy dispersive X-ray analysis. The primary determinants of calculi embolism include intrarenal pressure, and volume and viscosity of the calculi fragments formation. Vascular intravasation of smashed calculi might increase pulmonary vascular resistance and hypoxemia and decrease cardiac output.This case report intends to provide information for clinicians to consider the probability of intraoperative calculi embolism during lithotripsies when patients develop typical symptoms of acute pulmonary embolism.
Liu, D D; Hsieh, N-K; Chen, H I
2008-11-01
Several experimental models have been used to produce intravascular fat embolism. We have developed a simple technique to induce fat embolism using corn oil emulsified with distilled water to form fatty micelles. Fat embolism was produced by intravenous administration of these fatty micelles in anaesthetised rats, causing alveolar oedema, haemorrhage and increased lung weight. Histopathological examination revealed fatty droplets and fibrin thrombi in the lung, kidney and brain. The arteriolar lumen was filled with fatty deposits. Following fat embolism, hypoxia and hypercapnia occurred. The plasma phospholipase A(2), nitrate/nitrite, methylguidanidine and proinflammatory cytokines were significantly increased. Mass spectrometry showed that the main ingredient of corn oil was oleic acid. This simple technique may be applied as a new animal model for the investigation of the mechanisms involved in the fat embolism syndrome.
Costa, André Nathan; Mendes, Daniel Melo; Toufen, Carlos; Arrunátegui, Gino; Caruso, Pedro; de Carvalho, Carlos Roberto Ribeiro
2008-08-01
Fat embolism is defined as mechanical blockage of the vascular lumen by circulating fat globules. Although it primarily affects the lungs, it can also affect the central nervous system, retina, and skin. Fat embolism syndrome is a dysfunction of these organs caused by fat emboli. The most common causes of fat embolism and fat embolism syndrome are long bone fractures, although there are reports of its occurrence after cosmetic procedures. The diagnosis is made clinically, and treatment is still restricted to support measures. We report the case of a female patient who developed adult respiratory distress syndrome due to fat embolism in the postoperative period following liposuction and fat grafting. In this case, the patient responded well to alveolar recruitment maneuvers and protective mechanical ventilation. In addition, we present an epidemiological and pathophysiological analysis of fat embolism syndrome after cosmetic procedures.
Endovascular uterine artery interventions
Das, Chandan J; Rathinam, Deepak; Manchanda, Smita; Srivastava, D N
2017-01-01
Percutaneous vascular embolization plays an important role in the management of various gynecologic and obstetric abnormalities. Transcatheter embolization is a minimally invasive alternative procedure to surgery with reduced morbidity and mortality, and preserves the patient's future fertility potential. The clinical indications for transcatheter embolization are much broader and include many benign gynecologic conditions, such as fibroid, adenomyosis, and arteriovenous malformations (AVMs), as well as intractable bleeding due to inoperable advanced-stage malignancies. The most well-known and well-studied indication is uterine fibroid embolization. Uterine artery embolization (UAE) may be performed to prevent or treat bleeding associated with various obstetric conditions, including postpartum hemorrhage (PPH), placental implantation abnormality, and ectopic pregnancy. Embolization of the uterine artery or the internal iliac artery also may be performed to control pelvic bleeding due to coagulopathy or iatrogenic injury. This article discusses these gynecologic and obstetric indications for transcatheter embolization and reviews procedural techniques and outcomes. PMID:29379246
Alternative Treatment for Bleeding Peristomal Varices: Percutaneous Parastomal Embolization
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pabon-Ramos, Waleska M., E-mail: waly.pr@duke.edu; Niemeyer, Matthew M.; Dasika, Narasimham L., E-mail: narasimh@med.umich.edu
2013-10-15
Purpose: To describe how peristomal varices can be successfully embolized via a percutaneous parastomal approach. Methods: The medical records of patients who underwent this procedure between December 1, 2000, and May 31, 2008, were retrospectively reviewed. Procedural details were recorded. Median fluoroscopy time and bleeding-free interval were calculated. Results: Seven patients underwent eight parastomal embolizations. The technical success rate was 88 % (one failure). All embolizations were performed with coils combined with a sclerosant, another embolizing agent, or both. Of the seven successful parastomal embolizations, there were three cases of recurrent bleeding; the median time to rebleeding was 45 daysmore » (range 26-313 days). The remaining four patients did not develop recurrent bleeding during the follow-up period; their median bleeding-free interval was 131 days (range 40-659 days). Conclusion: This case review demonstrated that percutaneous parastomal embolization is a feasible technique to treat bleeding peristomal varices.« less
PTA of supra-aortic arteries with temporary balloon occlusion to avoid distal embolism.
Koike, T; Minakawa, T; Abe, H; Takeuchi, S; Sasaki, O; Nishimaki, K; Tanaka, R
1992-03-01
Percutaneous transluminal angioplasty (PTA) was carried out in eight patients with cervical arterial stenosis; six in the subclavian and brachiocephalic arteries (5 with subclavian steal syndrome), one in the common carotid artery, and one in both the brachiocephalic and common carotid arteries (with subclavian steal syndrome). The PTA balloon catheters were introduced via the femoral artery in seven and brachial artery in one. To prevent distal embolization through the vertebral and internal carotid arteries, the blood flow in these vessels was temporarily occluded with a balloon catheter. The dilation of the stenotic areas was generally satisfactory. Antegrade blood flow was promptly obtained in the vertebral artery even in patients with subclavian steal syndrome. In all patients, the clinical symptoms improved. Two patients underwent repeat PTA because of restenosis.
Computed tomographic findings of cerebral fat embolism following multiple bone fractures.
Law, Huong Ling; Wong, Siong Lung; Tan, Suzet
2013-02-01
Fat embolism to the lungs and brain is an uncommon complication following fractures. Few reports with descriptions of computed tomographic (CT) findings of emboli to the brain or cerebral fat embolism are available. We report a case of cerebral fat embolism following multiple skeletal fractures and present its CT findings here.
USDA-ARS?s Scientific Manuscript database
Drought induces xylem embolism formation, but grapevines can refill blocked conduits to restore transport capacity. It is unknown whether vulnerability to embolism formation and ability to repair differ among grapevine species. We analyzed in vivo embolism formation and repair using x-ray microtomog...
Selective arterial embolization with gelatin particles for refractory knee hemarthrosis.
Yamagami, Takuji; Yoshimatsu, Rika; Miura, Hiroshi; Arai, Yuji; Terauchi, Ryu; Nakagawa, Shuji; Yamada, Kei
2013-01-01
We aimed to evaluate the feasibility and safety of selective arterial embolization for refractory knee hemarthrosis. Transcatheter arterial embolization for refractory knee hemarthrosis was performed on five female patients (median age, 77 years; range, 71-80 years) between May 2009 and September 2012. Selective arterial embolization of the feeding artery was performed using a 2.5 F microcatheter coaxially advanced from a 5 F catheter with its tip positioned in the superficial femoral artery. One- or two-millimeter gelatin particles were used as embolic agents. In all patients, transarterial embolization performed successfully after arteriography showed nontumorous staining around the knee joint. The feeding arteries were the lateral superior genicular artery in all five patients, the lateral inferior genicular artery in four patients, the medial superior genicular artery in one patient, the medial inferior genicular artery in one patient, the middle genicular artery in one patient, and the descending genicular artery in one patient. In all five patients, staining was remarkably diminished around the knee joint after the embolization procedure. No complication was observed. The hemarthrosis improved after the embolization, and the postoperative course has been uneventful with no recurrence in any patient. These results suggest that selective arterial embolization for refractory hemarthrosis of the knee is safe and useful.
McCully
1999-03-01
Embolism and refilling of vessels was monitored directly by cryomicroscopy of field-grown corn (Zea mays L.) roots. To test the reliability of an earlier study showing embolism refilling in roots at negative leaf water potentials, embolisms were counted, and root water potentials (Psiroot) and osmotic potentials of exuded xylem sap from the same roots were measured by isopiestic psychrometry. All vessels were full at dawn (Psiroot -0.1 MPa). Embolisms were first seen in late metaxylem vessels at 8 AM. Embolized late metaxylem vessels peaked at 50% at 10 AM (Psiroot -0.1 MPa), fell to 44% by 12 PM (Psiroot -0.23 MPa), then dropped steadily to zero by early evening (Psiroot -0.28 MPa). Transpiration was highest (8.5 μg cm-2 s-1) between 12 and 2 PM when the percentage of vessels embolized was falling. Embolized vessels were refilled by liquid moving through their lateral walls. Xylem sap was very low in solutes. The mechanism of vessel refilling, when Psiroot is negative, requires further investigation. Daily embolism and refilling in roots of well-watered plants is a normal occurrence and may be a component of an important hydraulic signaling mechanism between roots and shoots.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Meneses, Luis, E-mail: lmeneseq@gmail.com; Fava, Mario; Diaz, Pia
We present our experience with embolization of incompetent pelvic veins (IPV) in women with recurrence of varicose veins (VV) in lower limbs, as well as symptoms of pelvic congestion syndrome (PCS), after first surgery. In addition, we evaluated the effects of embolization in decreasing the symptoms of VV before surgery as well as its effects on PCS symptoms. We included 10 women who had consulted a vascular surgeon because of recurrent VV in lower limbs after surgery. All of these patients were included in the study because they also had symptoms of PCS, probably due to IPV. In patients whomore » had confirmed IPV, we performed embolization before a second surgery. VV and PCS were assessed before and at 3 months after embolization (before the second surgery) using a venous clinical severity score (VCSS) and a visual analog pain scale (VAS), respectively. Patients were controlled between 3 and 6 months after embolization. Paired Student t test analysis was used for comparing data before and after embolization. Fifteen vein segments in 10 women were suitable for embolization. There was a significant (p < 0.001) decrease of VCSS after embolization, and recurrence of VV was not detected within a period of 6 months. There was also significant (p < 0.01) relief of chronic pelvic pain related to PCS evaluated using VAS at 3 months after embolization. Embolization decreases the risk of VV recurrence after surgery and also improves PCS symptoms in women with VV in lower limbs and IPV.« less
Griffiths, Ewen A; McDonald, Chris R; Bryant, Robert V; Devitt, Peter G; Bright, Tim; Holloway, Richard H; Thompson, Sarah K
2016-05-01
With proton pump inhibitors and current sophisticated endoscopic techniques, the number of patients requiring surgical intervention for upper gastrointestinal bleeding has decreased considerably while trans-arterial embolization is being used more often. There are few direct comparisons between the effectiveness of surgery and embolization. A retrospective study of patients from two Australian teaching hospitals who had surgery or trans-arterial embolization (n = 103) for severe upper gastrointestinal haemorrhage between 2004 and 2012 was carried out. Patient demographics, co-morbidities, disease pathology, length of stay, complications, and overall clinical outcome and mortality were compared. There were 65 men and 38 women. The median age was 70 (range 36-95) years. Patients requiring emergency surgical intervention (n = 79) or trans-arterial embolization (n = 24) were compared. The rate of re-bleeding after embolization (42%) was significantly higher compared with the surgery group (19%) (P = 0.02). The requirement for further intervention (either surgery or embolization) was also higher in the embolization group (33%) compared with the surgery group (13%) (P = 0.03). There was no statistical difference in mortality between the embolization group (5/24, 20.8%) and the surgical group (13/79, 16.5%) (P = 0.75). Emergency surgery and embolization are required in 2.6% of patients with upper gastrointestinal bleeding. Both techniques have high mortalities reflecting the age, co-morbidities and severity of bleeding in this patient group. © 2014 Royal Australasian College of Surgeons.
Halbertsma, Feico J J; Mohns, Thilo; Bok, Levinus A; Niemarkt, Hendrik J; Kramer, Boris W
2015-08-01
Chest compressions (CC) during cardiopulmonary resuscitation (CPR) are the cornerstone of adult CPR protocols and are meant to restore circulation and improve outcome. Although adverse effects such as air-embolisms have been reported, these are rare and considered to be outweighed by beneficial effect. In newborns, however, the lung tissue is more fragile. Thus, the high intra-thoracic pressures resulting from CC may make the newborns more vulnerable for air-embolisms. We studied the postmortem prevalence of air-embolism in neonates that have received CPR. Prospective cohort analysis of newborns receiving CC during CPR. CPR was performed by trained staff according to ILCOR guidelines, in a tertiary hospital. Air-embolisms were sought after using CT/MRI and autopsy. During a 61/2 year period (2007-2014), n = 56 newborns received CC. Newborns were resuscitated following severe perinatal hypoxia, or due to complications during NICU treatment. In n = 14 (25.0%) circulation could not be restored (mean CPR duration: 32.7 ± 15.2 min). Post-mortem CT/MRI was performed in n = 9, of whom n = 8 (88.9%) had air-embolisms. Autopsy was performed in n = 9. The air-embolisms could not be retraced on autopsy except for n = 1 patient. In patients with CPR resulting in restored circulation (n = 42), no CT or MRI was performed for comparison due to radiation and/or hemodynamic instability. Cerebral ultrasound could not identify or exclude air-embolisms in this subgroup. Post-mortem CT after prolonged resuscitation showed a high prevalence of intravascular air-embolism. Autopsy was not suited to detect air-embolism. The clinical importance of air-embolisms on the lethal outcome needs further research. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Onyx versus nBCA and coils in the treatment of intracranial dural arteriovenous fistulas.
Choo, Douglas M; Shankar, Jai Jai Shiva
2016-04-01
Intracranial dural arteriovenous fistulas (DAVFs) with cortical venous drainage have significant morbidity and mortality. Complete closure of these lesions is necessary to reduce these risks. The purpose of our study was to compare the outcome of DAVFs treated with Onyx versus those treated with n-Butyl Cyanoacrylate (nBCA) and coil embolization in a case-control study. Compared with nBCA and coil embolization, we hypothesized that Onyx embolization for DAVF is safer and has a higher chance of complete obliteration, with no need for post-embolization surgery for the DAVF. From 1998 to 2015, 29 patients who had DAVFs were treated with endovascular embolization. Of these, 24 patients had imaging available for analysis. Successful closure rates, complications, and procedure time were compared between the embolization techniques. The chance of not requiring post-embolization surgery with Onyx (81.8%) was significantly higher (p = 0.005) than with nBCA (22.22%). The complication rate with Onyx (9.1%) tended to be lower compared with that of nBCA (22.22%; p = 0.37). Procedural time was not significantly different between Onyx (mean 267 minutes) and nBCA (mean 288 minutes) (p = 0.59). The odds ratio of a DAVF being treated with Onyx and then requiring no follow-up surgery was 17.5 (95% CI 1.97-155.4). Our case-control study suggests that Onyx embolization is superior to nBCA and coil embolization in completely obliterating DAVFs, with higher odds of no post-embolization surgery. We also found that Onyx is safe for embolization of DAVFs, with no associated neurological mortality and morbidity. © The Author(s) 2016.
Zuckerman, Scott L; Lakomkin, Nikita; Magarik, Jordan A; Vargas, Jan; Stephens, Marcus; Akinpelu, Babatunde; Spiotta, Alejandro M; Ahmed, Azam; Arthur, Adam S; Fiorella, David; Hanel, Ricardo; Hirsch, Joshua A; Hui, Ferdinand K; James, Robert F; Kallmes, David F; Meyers, Philip M; Niemann, David B; Rasmussen, Peter; Turner, Raymond D; Welch, Babu G; Mocco, J
2018-05-01
The angiographic evaluation of previously coiled aneurysms can be difficult yet remains critical for determining re-treatment. The main objective of this study was to determine the inter-rater reliability for both the Raymond Scale and per cent embolization among a group of neurointerventionalists evaluating previously embolized aneurysms. A panel of 15 neurointerventionalists examined 92 distinct cases of immediate post-coil embolization and 1 year post-embolization angiographs. Each case was presented four times throughout the study, along with alterations in demographics in order to evaluate intra-rater reliability. All respondents were asked to provide the per cent embolization (0-100%) and Raymond Scale grade (1-3) for each aneurysm. Inter-rater reliability was evaluated by computing weighted kappa values (for the Raymond Scale) and intraclass correlation coefficients (ICC) for per cent embolization. 10 neurosurgeons and 5 interventional neuroradiologists evaluated 368 simulated cases. The agreement among all readers employing the Raymond Scale was fair (κ=0.35) while concordance in per cent embolization was good (ICC=0.64). Clinicians with fewer than 10 years of experience demonstrated a significantly greater level of agreement than the group with greater than 10 years (κ=0.39 and ICC=0.70 vs κ=0.28 and ICC=0.58). When the same aneurysm was presented multiple times, clinicians demonstrated excellent consistency when assessing per cent embolization (ICC=0.82), but moderate agreement when employing the Raymond classification (κ=0.58). Identifying the per cent embolization in previously coiled aneurysms resulted in good inter- and intra-rater agreement, regardless of years of experience. The strong agreement among providers employing per cent embolization may make it a valuable tool for embolization assessment in this patient population. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Maurer, C A; Renzulli, P; Baer, H U; Mettler, D; Uhlschmid, G; Neuenschwander, P; Suter, U W; Triller, J; Zimmermann, A
2000-02-01
In an attempt to overcome some of the problems encountered with the materials available for liver embolisation, we investigated a novel radiopaque polymer of the polyurethane family (Degra-Bloc). Hepatic artery embolisation of one liver lobe using polyurethane was performed in 19 healthy pigs. Microcirculatory changes were assessed by laser Doppler flowmetry. Radiological and pathological examinations of the livers, hearts and lungs removed provided information about the extent and effect of the embolisation. None of the pigs died due to hepatic failure or toxicity of polyurethane. Microcirculation of embolised liver lobes significantly decreased from 106 (+/-15) perfusion units (PU) to 45 (+/-6) PU immediately after embolisation and further to 28 (+/-7) PU before euthanasia. At this time conventional and angiographic X-ray controls demonstrated the radiopaque casts extending up to the peripheral arteries with signs of degradation over time but without formation of collateral vessels. The main pathological findings consisted of destruction of the portal tract structures and also of large areas of liver necrosis. Polyurethane was encountered in arterioles as small as 10-20 microm, but not in liver sinusoids, hearts or lungs. The novel polymer called DegraBloc is a biocompatible, slowly degradable, radiopaque embolic agent. The occlusion of the arterial tree up to the smallest arteriolar diameter combined with concomitant portal vein occlusion leads to sharp segmental necrosis in pig livers without formation of significant collaterals and without systemic embolism. In the treatment of liver tumours polyurethane might provide a promising alternative to conventional embolic materials, provided that it is used with care in patients with advanced liver cirrhosis.
Maybody, Majid; Madoff, David C.; Thornton, Raymond H; Morales, Steven A; Moskowitz, Chaya S; Hsu, Meier; Brody, Lynn A; Brown, Karen T; Covey, Anne M
2017-01-01
Purpose To report 3 new cases of catheter-directed endovascular application of thrombin and explore trends by analysis of published case series. Materials and Methods Institutional Review Board approved this retrospective study. All cases of non-tumoral arterial embolization performed from January 2003 to January 2015 at our institution were retrospectively reviewed. Thrombin was used in 7 of 589 cases. In 3 cases intra arterial thrombin was injected via catheter to treat active hemorrhage. Four cases were excluded due to percutaneous injection into visceral pseudoaneurysms (n=3) and making ex vivo autologous clot to be injected via catheter (n=1). Fisher’s exact and the Wilcoxon rank sum tests were used to assess for association with acute nontarget thrombosis. Results Catheter-directed thrombin was used in 3/589 (0.5%) cases at our institution. All three cases were technically successful with no further bleeding (100%). Nontarget thrombosis of proximal branches occurred in 2 patients (67%) with no significant clinical consequences. Including our 3 cases, a total of 28 cases were reviewed. Of the variables examined - location (p=0.99), size (p=0.66) and etiology of vascular lesion (p=0.92), pseudoaneurysm neck anatomy (p=0.14), thrombin units (p=0.47), volume (p=0.76) or technique of use of small doses (p=0.99), use of other embolic material (p=0.67) and use of adjunct techniques (p=0.99) - none were found to be significantly associated with acute nontarget thrombosis. Technical success was 96% with no reports of reperfusion after treatment. Conclusions Catheter-directed endovascular thrombin can be an additional tool to treat pseudoaneurysms not amenable to conventional embolization. Further studies are required to optimize technique and outcomes. PMID:27936421
DOE Office of Scientific and Technical Information (OSTI.GOV)
Blasel, Stella, E-mail: Stella.Blasel@kgu.de; Hattingen, Elke; Berkefeld, Joachim
2009-07-15
The detection of clinically silent ischemic lesions on postprocedural diffusion-weighted magnetic resonance images has become a preferred method for the description of embolic risks. The purpose of this single-center study was to evaluate whether diffusion-weighted imaging (DWI) could determine material related or technical risk factors of filter-protected carotid stenting. Eighty-four patients with symptomatic severe ({>=}60%) carotid artery stenoses received filter-protected carotid stenting. Standard DWI (b = 1000) was performed within 48 h before and after carotid stenting. The occurrence and load of new postinterventional DWI lesions were assessed. Multivariate analysis was performed to determine risk factors associated with DWI lesions,more » with emphasis on technical factors such as use of different access devices (guiding catheter method vs. long carotid sheath method), type of stent (open-cell nitinol stent vs. closed-cell Wallstent), and protective device (filters with 80-{mu}m vs. 110-120-{mu}m pore size). Markers for generalized atherosclerosis and for degree and site of stenosis were assessed to allow comparison of adequate risk profiles. Access, protective device, and stent type were not significantly associated with new embolic DWI lesions when we compared patients with equivalent risk profiles (long carotid sheath method 48% [11 of 23] vs. guiding catheter method 44% [27 of 61], Wallstent 47% [15 of 32] vs. nitinol stent 44% [23 of 52], and small pore size filter 61% [11 of 18] vs. large pore size filter 41% [27 of 66]). Single-center DWI studies with a moderate number of cases are inadequate for proper assessment of the embolic risk of technical- or material-related risk factors in carotid stenting. Larger multicenter studies with more cases are needed.« less
2014-01-01
Background Embolic events are a major cause of morbidity and mortality in patients with infective endocarditis. We analyzed the database of the prospective cohort study SEI in order to identify factors associated with the occurrence of embolic events and to develop a scoring system for the assessment of the risk of embolism. Methods We retrospectively analyzed 1456 episodes of infective endocarditis from the multicenter study SEI. Predictors of embolism were identified. Risk factors identified at multivariate analysis as predictive of embolism in left-sided endocarditis, were used for the development of a risk score: 1 point was assigned to each risk factor (total risk score range: minimum 0 points; maximum 2 points). Three categories were defined by the score: low (0 points), intermediate (1 point), or high risk (2 points); the probability of embolic events per risk category was calculated for each day on treatment (day 0 through day 30). Results There were 499 episodes of infective endocarditis (34%) that were complicated by ≥ 1 embolic event. Most embolic events occurred early in the clinical course (first week of therapy: 15.5 episodes per 1000 patient days; second week: 3.7 episodes per 1000 patient days). In the total cohort, the factors associated with the occurrence of embolism at multivariate analysis were prosthetic valve localization (odds ratio, 1.84), right-sided endocarditis (odds ratio, 3.93), Staphylococcus aureus etiology (odds ratio, 2.23) and vegetation size ≥ 13 mm (odds ratio, 1.86). In left-sided endocarditis, Staphylococcus aureus etiology (odds ratio, 2.1) and vegetation size ≥ 13 mm (odds ratio, 2.1) were independently associated with embolic events; the 30-day cumulative incidence of embolism varied with risk score category (low risk, 12%; intermediate risk, 25%; high risk, 38%; p < 0.001). Conclusions Staphylococcus aureus etiology and vegetation size are associated with an increased risk of embolism. In left-sided endocarditis, a simple scoring system, which combines etiology and vegetation size with time on antimicrobials, might contribute to a better assessment of the risk of embolism, and to a more individualized analysis of indications and contraindications for early surgery. PMID:24779617
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yu, Simon Chun Ho, E-mail: simonyu@cuhk.edu.hk; Cho, Carmen Chi Min; Hung, Esther Hiu Yee
BackgroundWe aimed to evaluate the effectiveness of PAE in weaning of catheter and relieving obstructive urinary symptoms in patients with acute urinary retention (AUR) due to benign prostatic hypertrophy (BPH) and failed trial without catheter (TWOC).Materials and MethodsIn this prospective study approved by the institutional review board, a signed informed consent was obtained. Eighteen consecutive patients with AUR due to BPH and failed TWOC were recruited. Nineteen consecutive patients with BPH but without AUR were recruited as a control. Patients with CTA evidence of arterial occlusion or significant stenosis along the prostate artery access path were excluded. PAE was performedmore » using microspheres (100–300 μm diameter). Outcome assessment included successful weaning of catheter in 2 weeks, procedure-related complications, change of symptomatology and urodynamic findings at 1 month as compared to baseline, percent non-perfused prostate volume, and prostate volume reduction on MRI at 2 weeks.ResultsTwo patients in the study group and four in the control group were excluded due to arterial pathology. Embolization of bilateral prostate arteries was achieved in all patients in both the groups (100%). There was no complication. The catheter was successfully weaned in 87.5% (14/16) of patients within 14 days in the treatment group. There was no significant difference in patient demographics, prostate characteristics, and all outcome assessment parameters between both the groups.ConclusionsPAE was probably safe and effective in weaning of catheter and relieving obstructive urinary symptoms in patients due to BPH, with treatment outcomes comparable to those without AUR.« less
Magnetic resonance imaging of water ascent in embolized xylem vessels of grapevine stem segments
Mingtao Wang; Melvin T. Tyree; Roderick E. Wasylishen
2013-01-01
Temporal and spatial information about water refilling of embolized xylem vessels and the rate of water ascent in these vessels is critical for understanding embolism repair in intact living vascular plants. High-resolution 1H magnetic resonance imaging (MRI) experiments have been performed on embolized grapevine stem segments while they were...
Pulmonary Embolism as the Initial Presentation of Testicular Carcinoma
Berber, Ilhami; Erkurt, Mehmet Ali; Ulutas, Ozkan; Ediz, Caner; Nizam, Ilknur; Kırıcı Berber, Nurcan; Unlu, Serkan; Koroglu, Reyhan; Koroglu, Mustafa; Akpolat, Nusret
2013-01-01
Objective. The risk of pulmonary embolism is well recognized as showing an increase in oncological patients. We report a case presenting with pulmonary embolism initially, which was then diagnosed with testicular cancer. Clinical Presentation and Intervention. A 25-year-old man was admitted to the emergency department with a complaint of dyspnoea. Thoracic tomography, lung ventilation/perfusion scintigraphy, and an increased D-dimer level revealed pulmonary embolism. For the aetiology of pulmonary embolism, a left orchiectomy was performed and the patient was diagnosed with a germinal cell tumour of the testicle. Conclusion. In this paper, we present a patient for whom pulmonary embolism was the initial presentation, and a germinal cell tumour was diagnosed later during the search for the aetiology. PMID:24383024
Release mechanism utilizing shape memory polymer material
Lee, Abraham P.; Northrup, M. Allen; Ciarlo, Dino R.; Krulevitch, Peter A.; Benett, William J.
2000-01-01
Microfabricated therapeutic actuators are fabricated using a shape memory polymer (SMP), a polyurethane-based material that undergoes a phase transformation at a specified temperature (Tg). At a temperature above temperature Tg material is soft and can be easily reshaped into another configuration. As the temperature is lowered below temperature Tg the new shape is fixed and locked in as long as the material stays below temperature Tg. Upon reheating the material to a temperature above Tg, the material will return to its original shape. By the use of such SMP material, SMP microtubing can be used as a release actuator for the delivery of embolic coils through catheters into aneurysms, for example. The microtubing can be manufactured in various sizes and the phase change temperature Tg is determinate for an intended temperature target and intended use.
Massive cerebral involvement in fat embolism syndrome and intracranial pressure management.
Kellogg, Robert G; Fontes, Ricardo B V; Lopes, Demetrius K
2013-11-01
Fat embolism syndrome (FES) is a common clinical entity that can occasionally have significant neurological sequelae. The authors report a case of cerebral fat embolism and FES that required surgical management of intracranial pressure (ICP). They also discuss the literature as well as the potential need for neurosurgical management of this disease entity in select patients. A 58-year-old woman presented with a seizure episode and altered mental status after suffering a right femur fracture. Head CT studies demonstrated hypointense areas consistent with fat globules at the gray-white matter junction predominantly in the right hemisphere. This CT finding is unique in the literature, as other reports have not included imaging performed early enough to capture this finding. Brain MR images obtained 3 days later revealed T2-hyperintense areas with restricted diffusion within the same hemisphere, along with midline shift and subfalcine herniation. These findings steered the patient to the operating room for decompressive hemicraniectomy. A review of the literature from 1980 to 2012 disclosed 54 cases in 38 reports concerning cerebral fat embolism and FES. Analysis of all the cases revealed that 98% of the patients presented with mental status changes, whereas only 22% had focal signs and/or seizures. A good outcome was seen in 57.6% of patients with coma and/or abnormal posturing on presentation and in 90.5% of patients presenting with mild mental status changes, focal deficits, or seizure. In the majority of cases ICP was managed conservatively with no surgical intervention. One case featured the use of an ICP monitor, while none featured the use of hemicraniectomy.
Bronchial Artery Embolization for Hemoptysis Due to Benign Diseases: Immediate and Long-Term Results
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kato, Akira; Kudo, Sho; Matsumoto, Koichi
Purpose: To clarify the immediate effect and long-term results of bronchial artery embolization (BAE) for hemoptysis due to benign diseases and the factors influencing the outcomes.Methods: One hundred and one patients (aged 34-89 years) received bronchial artery embolization with polyvinyl alcohol particles and gelatin sponge for massive or continuing moderate hemoptysis caused by benign pulmonary diseases and resistant to medical treatment.Results: After BAE, bleeding stopped in 94 patients (94%). The immediate effect was unfavorable in cases where feeder vessels were overlooked or the embolization of the intercostal arteries was insufficient. Long-term cumulative hemoptysis non recurrence rates after the initial embolizationmore » were 77.7% for 1 year and 62.5% for 5 years. In bronchitis (n 9) and active tuberculosis (n = 4) groups, an excellent (100%) 5-year cumulative non recurrence rate was obtained. The rate was lower in groups with pneumonia/abscess/pyothorax (n = 8) or with pulmonary aspergillosis (n = 9) (53.3%, 1-year cumulative non recurrence). There were higher incidences of early recurrence among patients with massive hemorrhage or more marked vascularity and systemic artery-pulmonary artery shunt in angiography: however, these trends were not statistically significant. Conclusions: BAE can yield long-term benefit in patients with hemoptysis due to benign diseases. Technical problems in the procedure had an impact on the short-term effect. The degree of hemorrhage or the severity of angiographical findings were not significant factors affecting the outcome. The most significant factor affecting long-term results was whether the inflammation caused by the underlying disease was medically well controlled.« less
Post-dive ultrasound detection of gas in the liver of rats and scuba divers.
L'abbate, Antonio; Marabotti, Claudio; Kusmic, Claudia; Pagliazzo, Antonino; Navari, Alessandro; Positano, Vincenzo; Palermo, Mario; Benassi, Antonio; Bedini, Remo
2011-09-01
In a previous study, we obtained histologic documentation of liver gas embolism in the rat model of rapid decompression. The aim of the study was to assess in the same model occurrence and time course of liver embolism using 2-D ultrasound imaging, and to explore by this means putative liver gas embolism in recreational scuba divers. Following 42 min compression at 7 ATA breathing air and 12 min decompression, eight surviving female rats were anesthetized and the liver imaged by ultrasound at 20 min intervals up to 120 min. A significant enhancement of echo signal was recorded from 60 to 120 min as compared to earlier post-decompression times. Enzymatic markers of liver damage (AST, ALT, and GGT) increased significantly at 24 h upon decompression. Twelve healthy experienced divers were studied basally and at 15-min intervals up to 60 min following a 30-min scuba dive at 30 msw depth. At 30 min upon surfacing echo images showed significant signal enhancement that progressed and reached plateau at 45 and 60 min. Total bilirubin at 24 h increased significantly (p = 0.02) with respect to basal values although within the reference range. In conclusion, 2-D ultrasound liver imaging allowed detection of gas embolism in the rat and defined the time course of gas accumulation. Its application to scuba divers revealed liver gas accumulation in all subjects in the absence of clear-cut evidence of liver damage or of any symptom. The clinical significance of our findings remains to be investigated.
Jagadeesan, Bharathi D; Grigoryan, Mikayel; Hassan, Ameer E; Grande, Andrew W; Tummala, Ramachandra P
2013-12-01
Ethylene vinyl alcohol copolymer (Onyx) is widely used for the embolization of arteriovenous malformations (AVMs) of the brain, head, and neck. Balloon-assisted Onyx embolization may provide additional unique advantages in the treatment of AVMs in comparison with traditional catheter-based techniques. To report our initial experience in performing balloon-assisted AVM embolization for brain and neck AVMs with the use of the new Scepter-C and Scepter-XC coaxial dual-lumen balloon microcatheters. Balloon-assisted transarterial embolization was performed in a series of 7 patients with AVMs (4 with brain AVMs, 1 with a dural arteriovenous fistula, and 2 with neck AVMs) by using Onyx delivered through the lumen of Scepter-C or Scepter XC coaxial balloon microcatheters. Following the initial balloon-catheter navigation into a feeding artery and the subsequent inflation of the balloon, the embolization was performed by using Onyx 18, Onyx 34, or both. A total of 12 embolization sessions were performed via 17 arterial feeders in these 7 patients. In 1 patient, there was an arterial perforation from the inflation of the balloon; in all others, the embolization goals were successfully achieved with no adverse events. The balloon microcatheters showed excellent navigability, and there were no problems with retrieval or with the repeated inflation and deflation of the balloons. A proximal Onyx plug, which is crucial in many AVM embolizations, was not necessary with this technique. Additionally, fluoroscopy and procedural times seemed lower with this technique compared with conventional embolization methods.
Seizures after Onyx embolization for the treatment of cerebral arteriovenous malformation.
de Los Reyes, K; Patel, A; Doshi, A; Egorova, N; Panov, F; Bederson, J B; Frontera, J A
2011-09-01
Onyx embolization of cerebral arteriovenous malformations (AVM) has become increasingly common. We explored the risk of seizures after Onyx use.A retrospective review was conducted of 20 patients with supratentorial brain arteriovenous malformation (AVM) who received Onyx embolization between 2006 and 2009. Baseline demographics, clinical history, seizure history, AVM characteristics and treatment were compared between those who developed post-onyx seizure and those who did not. MRIs were reviewed for edema following Onyx treatment.Of 20 patients who underwent Onyx embolization, the initial AVM presentation was hemorrhage in 40% (N=8). The median number of embolizations was two (range 1-4) and the median final obliteration amount was 90% (range 50-100%). A history of seizure was present in 50% (N=10) of patients pre-embolization and 12 (60%) patients received seizure medications (treatment or prophylaxis) prior to embolization. Seizur post-Onyx embolization occurred in 45% (N=9). The median time to seizur post-Onyx was seven days (range 0.3-210). Four patients (20%) with seizures post-Onyx had no seizure history. Two of these patients (10%) had no other identifiable cause for seizure other than recent Onyx embolization. Seizures in these two patients occurred within 24 hours of Onyx administration. Among patients with post-Onyx seizures, there was a trend toward larger AVM size (P=0.091) and lower percent obliteration (P=0.062). Peri-AVM edema was present in 75% of MRIs performed within one month of Onyx treatment and may represent a possible etiology for seizures.New onset seizures post-Onyx embolization are not uncommon. Further study of seizure prevention is warranted.
Preoperative spinal tumor embolization: an institutional experience with Onyx.
Ghobrial, George M; Chalouhi, Nohra; Harrop, James; Dalyai, Richard T; Tjoumakaris, Stavropoula; Gonzalez, L Fernando; Hasan, David; Rosenwasser, Robert H; Jabbour, Pascal
2013-12-01
Preoperative embolization has the potential to decrease intraoperative blood loss and facilitate spinal cord decompression and tumor resection. We report our institutional experience with the embolization of hypervascular extradural spinal tumors with Onyx as well as earlier embolic agents in a series of 28 patients. A retrospective case review was conducted on patients undergoing preoperative transarterial embolization of a spinal tumor between 1995 and 2012 at our institution. Twenty-eight patients met the inclusion criteria, with a mean age of 60.6 years. Twenty-eight patients had metastatic tumors. In 14 (50%) patients the metastases were from renal cell carcinomas. Fifty-four vessels were embolized using PVA, NBCA, Onyx, coils, or embospheres. Sixteen patients were treated with Onyx, 6 patients with PVA, 3 patients with embospheres, 2 patients with NBCA, and 3 patients with a combination of embolic agents. The average decrease in tumor blush was 97.8% with Onyx versus 92.7% with the rest of the embolic agents (p=0.08). The estimated blood loss was 1616ml (range 350-5000ml). Blood loss was 750cm(3) on average with Onyx versus 1844 with the rest of the embolic agents (p=0.14). The mean length of stay was 16 days. The mortality rate was zero. Pre- and post-operative modified Rankin Score (mRS) did not differ significantly in the series (3.12 versus 3.10, respectively, p=0.9). In our experience, the use of transarterial tumor embolization as an adjunct for spinal surgery is a safe and feasible option. Copyright © 2013 Elsevier B.V. All rights reserved.
Koo, M; Sabaté, A; Magalló, P; García, M A; Domínguez, J; de Lama, M E; López, S
2011-11-01
To assess conservative treatment of splenic injury due to trauma, following a protocol for computed tomography (CT) and angiographic embolization. To quantify the predictive value of CT for detecting bleeding and need for embolization. The care protocol developed by the multidisciplinary team consisted of angiography with embolization of lesions revealed by contrast extravasation under CT as well as embolization of grade III-V injuries observed, or grade I-II injuries causing hemodynamic instability and/or need for blood transfusion. We collected data on demographic variables, injury severity score (ISS), angiographic findings, and injuries revealed by CT. Pre-protocol and post-protocol outcomes were compared. The sensitivity and specificity of CT findings were calculated for all patients who required angiographic embolization. Forty-four and 30 angiographies were performed in the pre- and post-protocol periods, respectively. The mean (SD) ISSs in the two periods were 25 (11) and 26 (12), respectively. A total of 24 (54%) embolizations were performed in the pre-protocol period and 28 (98%) after implementation of the protocol. Two and 7 embolizations involved the spleen in the 2 periods, respectively; abdominal laparotomies numbered 32 and 25, respectively, and 10 (31%) vs 4 (16%) splenectomies were performed. The specificity and sensitivity values for contrast extravasation found on CT and followed by embolization were 77.7% and 79.5%. The implementation of this multidisciplinary protocol using CT imaging and angiographic embolization led to a decrease in the number of splenectomies. The protocol allows us to take a more conservative treatment approach.
Johnson, Daniel M; McCulloh, Katherine A; Woodruff, David R; Meinzer, Frederick C
2012-10-01
Angiosperm and coniferous tree species utilize a continuum of hydraulic strategies. Hydraulic safety margins (defined as differences between naturally occurring xylem pressures and pressures that would cause hydraulic dysfunction, or differences between pressures resulting in loss of hydraulic function in adjacent organs (e.g., stems vs. leaves) tend to be much greater in conifers than angiosperms and serve to prevent stem embolism. However, conifers tend to experience embolism more frequently in leaves and roots than angiosperms. Embolism repair is thought to occur by active transport of sugars into empty conduits followed by passive water movement. The most likely source of sugar for refilling is from nonstructural carbohydrate depolymerization in nearby parenchyma cells. Compared to angiosperms, conifers tend to have little parenchyma or nonstructural carbohydrates in their wood. The ability to rapidly repair embolisms may rely on having nearby parenchyma cells, which could explain the need for greater safety margins in conifer wood as compared to angiosperms. The frequent embolisms that occur in the distal portions of conifers are readily repaired, perhaps due to the abundant parenchyma in leaves and roots, and these distal tissues may act as hydraulic circuit breakers that prevent tension-induced embolisms in the attached stems. Frequent embolisms in conifer leaves may also be due to weaker stomatal response to changes in ambient humidity. Although there is a continuum of hydraulic strategies among woody plants, there appear to be two distinct 'behaviors' at the extremes: (1) embolism prevention and (2) embolism occurrence and subsequent repair. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Embolism Formation during Freezing in the Wood of Picea abies1
Mayr, Stefan; Cochard, Hervé; Améglio, Thierry; Kikuta, Silvia B.
2007-01-01
Freeze-thaw events can cause embolism in plant xylem. According to classical theory, gas bubbles are formed during freezing and expand during thawing. Conifers have proved to be very resistant to freeze-thaw induced embolism, because bubbles in tracheids are small and redissolve during thawing. In contrast, increasing embolism rates upon consecutive freeze-thaw events were observed that cannot be explained by the classical mechanism. In this study, embolism formation during freeze-thaw events was analyzed via ultrasonic and Cryo-scanning electron microscope techniques. Twigs of Picea abies L. Karst. were subjected to up to 120 freeze-thaw cycles during which ultrasonic acoustic emissions, xylem temperature, and diameter variations were registered. In addition, the extent and cross-sectional pattern of embolism were analyzed with staining experiments and Cryo-scanning electron microscope observations. Embolism increased with the number of freeze-thaw events in twigs previously dehydrated to a water potential of −2.8 MPa. In these twigs, acoustic emissions were registered, while saturated twigs showed low, and totally dehydrated twigs showed no, acoustic activity. Acoustic emissions were detected only during the freezing process. This means that embolism was formed during freezing, which is in contradiction to the classical theory of freeze-thaw induced embolism. The clustered pattern of embolized tracheids in cross sections indicates that air spread from a dysfunctional tracheid to adjacent functional ones. We hypothesize that the low water potential of the growing ice front led to a decrease of the potential in nearby tracheids. This may result in freezing-induced air seeding. PMID:17041033
Casting light on xylem vulnerability in an herbaceous species reveals a lack of segmentation.
Skelton, Robert P; Brodribb, Timothy J; Choat, Brendan
2017-04-01
Finding thresholds at which loss of plant functionality occurs during drought is critical for predicting future crop productivity and survival. Xylem resistance to embolism has been suggested as a key trait associated with water-stress tolerance. Although a substantial literature exists describing the vulnerability of woody stems to embolism, leaves and roots of herbaceous species remain under-represented. Also, little is known about vulnerability to embolism at a whole-plant scale or propagation of embolism within plants. New techniques to view the process of embolism formation provide opportunities to resolve long-standing questions. Here, we used multiple visual techniques, including X-ray micro-computed tomography and the optical vulnerability method, to investigate the spread of embolism within intact stems, leaves and roots of Solanum lycopersicum (common tomato). We found that roots, stems and leaves of tomato plants all exhibited similar vulnerability to embolism, suggesting that embolism rapidly propagates among tissues. Although we found scarce evidence for differentiation of xylem vulnerability among tissues at the scale of the whole plant, within a leaf the midrib embolized at higher water potentials than lower order veins. Substantial overlap between the onset of cavitation and incipient leaf damage suggests that cavitation represents a substantial damage to plants, but the point of lethal cavitation in this herbaceous species remains uncertain. © 2017 The Authors. New Phytologist © 2017 New Phytologist Trust.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Samuelson, Shaun D.; Louie, John D.; Sze, Daniel Y., E-mail: dansze@stanford.edu
Purpose. Avoidance of nontarget microsphere deposition via hepatoenteric anastomoses is essential to the safety of yttrium-90 radioembolization (RE). The hepatic hilar arterial network may remain partially patent after coil embolization of major arteries, resulting in persistent risk. We retrospectively reviewed cases where n-butyl cyanoacrylate (n-BCA) glue embolization was used to facilitate endovascular hepatic arterial skeletonization before RE. Methods. A total of 543 RE procedures performed between June 2004 and March 2012 were reviewed, and 10 were identified where n-BCA was used to embolize hepatoenteric anastomoses. Arterial anatomy, prior coil embolization, and technical details were recorded. Outcomes were reviewed to identifymore » subsequent complications of n-BCA embolization or nontarget RE. Results. The rate of complete technical success was 80 % and partial success 20 %, with one nontarget embolization complication resulting in a minor change in treatment plan. No evidence of gastrointestinal or biliary ischemia or infarction was identified, and no microsphere-related gastroduodenal ulcerations or other evidence of nontarget RE were seen. Median volume of n-BCA used was <0.1 ml. Conclusion. n-BCA glue embolization is useful to eliminate hepatoenteric networks that may result in nontarget RE, especially in those that persist after coil embolization of major vessels such as the gastroduodenal and right gastric arteries.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Borggreve, Alicia S., E-mail: alicia.borggreve@gmail.com; Landman, Anadeijda J. E. M. C., E-mail: ajemclandman@gmail.com; Vissers, Coco M. J., E-mail: coco.vissers@hotmail.com
PurposeTo study the effectiveness of prophylactic embolization of hepaticoenteric arteries to prevent gastrointestinal complications during radioembolization.MethodsA PubMed, Embase and Cochrane literature search was performed. We included studies assessing both a group of patients with and without embolization.ResultsOur search revealed 1401 articles of which title and abstract were screened. Finally, eight studies were included investigating 1237 patients. Of these patients, 456 received embolization of one or more arteries. No difference was seen in the incidence of gastrointestinal complications in patients with prophylactic embolization of the gastroduodenal artery (GDA), right gastric artery (RGA), cystic artery (CA) or hepatic falciform artery (HFA) comparedmore » to patients without embolization. Few complications were reported when microspheres were injected distal to the origin of these arteries or when reversed flow of the GDA was present. A high risk of confounding by indication was present because of the non-randomized nature of the included studies.ConclusionIt is advisable to restrict embolization to those hepaticoenteric arteries that originate distally or close to the injection site of microspheres. There is no conclusive evidence that embolization of hepaticoenteric arteries influences the risk of complications.« less
Cygan, Lukasz D; Weizberg, Moshe; Hahn, Barry
2016-09-01
Electrocardiography findings in patients with pulmonary embolism have been investigated since 1935. As medicine has evolved, more effective modalities have surpassed the electrocardiogram in diagnostic utility. Despite the advent of these other modalities, the diagnosis of pulmonary embolism remains elusive and the prognosis is variable amongst each clinical presentation of its pathology. After presenting a case of a resolving S1Q3T3 in subsequent electrocardiogram findings of a patient with pulmonary embolism, this literature review will provide information on a 21-point electrocardiogram scoring system that helps the emergency physician stratify the risk of a patient with an acute presentation of pulmonary embolism. Why should emergency care staff be aware of this? Given the time-sensitive nature of diagnosis and appropriate treatment, Electrocardiogram continues to be a tool in the assessment of patients with a clinical suspicion of pulmonary embolism. Based on the information provided, 21-point electrocardiogram score has been shown to have strong usefulness in assessing prognosis of patients presenting with acute pulmonary embolism. Copyright © 2016 Elsevier Ltd. All rights reserved.
Pereira, Luciano; Bittencourt, Paulo R L; Oliveira, Rafael S; Junior, Mauro B M; Barros, Fernanda V; Ribeiro, Rafael V; Mazzafera, Paulo
2016-07-01
Wood contains a large amount of air, even in functional xylem. Air embolisms in the xylem affect water transport and can determine plant growth and survival. Embolisms are usually estimated with laborious hydraulic methods, which can be prone to several artefacts. Here, we describe a new method for estimating embolisms that is based on air flow measurements of entire branches. To calculate the amount of air flowing out of the branch, a vacuum was applied to the cut bases of branches under different water potentials. We first investigated the source of air by determining whether it came from inside or outside the branch. Second, we compared embolism curves according to air flow or hydraulic measurements in 15 vessel- and tracheid-bearing species to test the hypothesis that the air flow is related to embolism. Air flow came almost exclusively from air inside the branch during the 2.5-min measurements and was strongly related to embolism. We propose a new embolism measurement method that is simple, effective, rapid and inexpensive, and that allows several measurements on the same branch, thus opening up new possibilities for studying plant hydraulics. © 2016 The Authors. New Phytologist © 2016 New Phytologist Trust.
Schiebler, Mark L.; Nagle, Scott K.; François, Christopher J.; Repplinger, Michael D.; Hamedani, Azita G.; Vigen, Karl K.; Yarlagadda, Rajkumar; Grist, Thomas M.; Reeder, Scott B.
2014-01-01
Purpose To determine the effectiveness of MR angiography for pulmonary embolism (MRA-PE) in symptomatic patients. Materials and Methods We retrospectively reviewed all patients whom were evaluated for possible pulmonary embolism (PE) using MRA-PE. A 3-month and 1-year from MRA-PE electronic medical record (EMR) review was performed. Evidence for venous thromboembolism (VTE) (or death from PE) within the year of follow-up was the outcome surrogate for this study. Results There were 190 MRA-PE exams performed with 97.4% (185/190) of diagnostic quality. There were 148 patients (120 F: 28 M) that had both a diagnostic MRA-PE exam and 1 complete year of EMR follow-up. There were 167 patients (137 F: 30 M) with 3 months or greater follow-up. We found 83% (139/167) and 81% (120/148) MRA-PE exams negative for PE at 3 months and 1 year, respectively. Positive exams for PE were seen in 14% (23/167). During the 1-year follow-up period, five patients (false negative) were diagnosed with DVT (5/148 = 3.4 %), and one of these patients also experienced a non–life-threatening PE. The negative predictive value (NPV) for MRA-PE was 97% (92–99; 95% CI) at 3 months and 96% (90–98; 95% CI) with 1 year of follow-up. Conclusion The NPV of MRA-PE, when used for the primary diagnosis of pulmonary embolism in symptomatic patients, were found to be similar to the published values for CTA-PE. In addition, the technical success rate and safety of MRA-PE were excellent. PMID:23553735
Kim, Sang Heum; Kong, Min Ho
2017-01-01
Objective Aneurysm clipping and simultaneous hematoma evacuation through open craniotomy is traditionally recommended for ruptured cerebral aneurysms accompanied by intracerebral or intrasylvian hemorrhages. We report our experience of adapting a less invasive treatment strategy in poor-grade patients with intracerebral or intrasylvian hemorrhages associated with ruptured cerebral aneurysms, where the associated ruptured cerebral aneurysms were managed by endovascular coil embolization, followed by stereotactic aspiration of hematomas (SRH) using urokinase. Materials and Methods We retrospectively analyzed 112 patients with ruptured cerebral aneurysms. There were accompanying intracerebral or intrasylvian hemorrhages in 36 patients (32.1%). The most common site for these ruptured aneurysms was the middle cerebral artery (MCA) (n = 15; 41.6%). Endovascular coil embolization followed by SRH using urokinase was performed in 9 patients (25%). Results In these 9 patients, the most common site of aneurysms was the MCA (n = 3; 33.4%); the hematoma volume ranged from 19.24 to 61.68 mL. Four patients who were World Federation of Neurological Surgeons (WFNS) grade-IV on admission, achieved favorable outcomes (Glasgow Outcome Score [GOS] 4 or 5) at 6-months postoperatively. In the five patients who were WFNS grade-V on admission, one achieved a favorable outcome, whereas 4 achieved GOS scores of 2 or 3, 6-months postoperatively. There was no mortality. Conclusion If immediate hematoma evacuation is not mandated by clinical or radiological signs of brain herniation, a less invasive strategy, such as endovascular coil embolization followed by SRH using urokinase, may be a good alternative in poor-grade patients with intracerebral or intrasylvian hemorrhages associated with ruptured cerebral aneurysms. PMID:29152466
Gonçalves, Octavio Meneghelli; Carnevale, Francisco Cesar; Moreira, Airton Mota; Antunes, Alberto Azoubel; Rodrigues, Vanessa Cristina; Srougi, Miguel
2016-10-01
The purpose of the study was to compare safety and efficacy outcomes following prostate artery embolization (PAE) for the treatment of lower urinary tract symptoms (LUTS) due to benign prostatic hyperplasia (BPH) with 100-300 versus 300-500 μm tris-acryl gelatin microspheres. Patients were prospectively treated between August 2011 and June 2013 to receive PAE with 100-300 μm (group A) or 300-500 μm (group B) tris-acryl gelatin microspheres. Patients were followed for a minimum of 12 months and were assessed for changes in International Prostate Symptom Score (IPSS), quality of life (QoL) index, prostate volume determined by magnetic resonance imaging, serum prostate specific antigen (PSA), and maximum urine flow rate (Qmax), as well as any treatment-related adverse events. Fifteen patients were included in each group, and PAE was technically successful in all cases. Both groups experienced significant improvement in mean IPSS, QoL, prostate volume, PSA, and Qmax (p < 0.05 for all). The differences observed between the two groups included a marginally insignificant more adverse events (p = 0.066) and greater mean serum PSA reduction at 3 months of follow-up (p = 0.056) in group A. Both 100-300 and 300-500 μm microspheres are safe and effective embolic agents for PAE to treat LUTS-related to BPH. Although functional and imaging outcomes did not differ significantly following use of the two embolic sizes, the greater incidence of adverse events with 100-300 μm microspheres suggests that 300-500 μm embolic materials may be more appropriate.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Guiu, Boris, E-mail: boris.guiu@chu-dijon.fr; Bize, Pierre; Gunthern, Daniel
Background: There is currently no consensus in the literature on which embolic agent induces the greatest degree of liver hypertrophy after portal vein embolization (PVE). Only experimental results in a pig model have demonstrated an advantage of n-butyl-cyanoacrylate (NBCA) over 3 other embolic materials (hydrophilic gel, small and large polyvinyl alcohol particles) for PVE. Therefore, the aim of this human study was to retrospectively compare the results of PVE using NBCA with those using spherical microparticles plus coils. Methods: A total of 34 patients underwent PVE using either NBCA (n = 20), or spherical microparticles plus coils (n = 14).more » PVE was decided according to preoperative volumetry on the basis of contrast-enhanced CT. Groups were compared for age, sex, volume of the left lobe before PVE and future remnant liver ratio (FRL) (volume of the left lobe/total liver volume - tumor volume). The primary end point was the increase in left lobe volume 1 month after PVE. Secondary end points were procedure complications and biological tolerance. Results: Both groups were similar in terms of age, sex ratio, left lobe volume, and FRL before PVE. NBCA induced a greater increase in volume after PVE than did microparticles plus coils (respectively, +74 {+-} 69 % and +23 {+-} 14 %, p < 0.05). The amount of contrast medium used for the procedure was significantly larger when microparticles and coils rather than NBCA were used (respectively, 264 {+-} 43 ml and 162 {+-} 34 ml, p < 0.01). The rate of PVE complications as well as the biological tolerance was similar in both groups. Conclusion: NBCA seems more effective than spherical microparticles plus coils to induce left-lobe hypertrophy.« less
Sawhney, Vinit; Domenichini, Giulia; Gamble, James; Furniss, Guy; Panagopoulos, Dimitrios; Lambiase, Pier; Rajappan, Kim; Chow, Anthony; Lowe, Martin; Sporton, Simon; Earley, Mark J; Dhinoja, Mehul; Campbell, Niall; Hunter, Ross J; Haywood, Guy; Betts, Tim R; Schilling, Richard J
2018-06-01
Endocardial left ventricular (LV) pacing is a viable alternative in patients with failed coronary sinus (CS) lead implantation. However, long-term thrombo-embolic risk remains unknown. Much of the data have come from a small number of centres. We examined the safety and efficacy of endocardial LV pacing to determine the long-term thrombo-embolic risk. Registries from four UK centres were combined to include 68 patients with endocardial leads with a mean follow-up of 20 months. These were compared to a matched 1:2 control group with conventional CS leads. Medical records were reviewed, and patients contacted for follow-up. Ischaemic stroke occurred in four patients (6%) in the endocardial arm providing an annual event rate (AER) of 3.6% over a 20 month follow-up; compared to 9 patients (6.6%) amongst controls with an AER of 3.4% over a 23-month follow-up. Regression analyses showed a significant association between sub-therapeutic international normalized ratio and stroke (P = 0.0001) in the endocardial arm. There was no association between lead material and mode of delivery (transatrial/transventricular) and stroke. Mortality rate was 12 and 15 per 100 patient years in the endocardial and control arm respectively with end-stage heart failure being the commonest cause. Endocardial LV lead in heart failure patients has a good success rate at 1.6 year follow-up. However, it is associated with a thrombo-embolic risk (which is not different from conventional CS leads) attributable to sub-therapeutic anticoagulation. Randomized control trials and studies on non-vitamin K antagonist oral anticoagulants are required to ascertain the potential of widespread clinical application of this therapeutic modality.
Portal vein embolization with plug/coils improves hepatectomy outcome.
Malinowski, Maciej; Geisel, Dominik; Stary, Victoria; Denecke, Timm; Seehofer, Daniel; Jara, Maximillian; Baron, Annekathrin; Pratschke, Johann; Gebauer, Bernhard; Stockmann, Martin
2015-03-01
Portal vein embolization (PVE) has become the standard of care before extended hepatectomy. Various PVE methods using different embolization materials have been described. In this study, we compared PVE with polyvinyl alcohol particles alone (PVA only) versus PVA with plug or coils (PVA + plug/coils). Patients undergoing PVE before hepatectomy were included. PVA alone was used until December 2013, thereafter plug or coils were placed in addition. The volume of left lateral liver lobe (LLL), clinical parameters, and liver function tests were measured before PVE and resection. A total of 43 patients were recruited into the PVA only group and 42 were recruited into the PVA + plug/coils group. There were no major differences between groups except significantly higher total bilirubin level before PVE in the PVA only group, which improved before hepatectomy. Mean LLL volume increased by 25.7% after PVE in the PVA only group and by 44% in the PVA + plug/coils group (P < 0.001). Recanalization was significantly less common in the PVA + plug/coils group. In multivariate regression, initial LLL volume and use of plug or coils were the only parameters influencing LLL volume increase. The postoperative liver failure rate was significantly reduced in PVA + plug/coils group (P = <0.001). PVE using PVA particles together with plug or coils is a safe and efficient method to increase future liver remnant volume. The additional central embolization with plug or coils led to an increased hypertrophy, due to lower recanalization rates, and subsequently decreased incidence of postoperative liver failure. No additional procedure-specific complications were observed in this series. Copyright © 2015 Elsevier Inc. All rights reserved.
Watanabe, Jun; Maruya, Jun; Nishimaki, Keiichi; Ito, Yasushi
2016-01-01
Most dural arteriovenous fistula (DAVF) in superior sagittal sinus (SSS) requires multimodal treatment. Onyx embolization is useful for DAVF; however, scalp artery embolization has cast extrusion risk. A 59-year-old male presented with involuntary movements of both legs and progressive dementia. Cerebral angiography demonstrated the DAVF in the SSS fed by bilateral superficial temporal, occipital, and middle meningeal arteries. The posterior SSS was thrombosed, and the main drainers were cortical veins. Combined treatment with transarterial embolization using Onyx and transvenous embolization using coils was performed. Although symptoms were improved, a small DAVF remained. Two months later, Onyx cast extrusion through the scalp was observed, requiring removal and debridement because of infection at the extrusion sites. Surgery for the residual DAVF would be difficult because of scalp condition; therefore, an additional endovascular treatment was conducted, completely occluding DAVF. Onyx embolization is useful for DAVF; however, scalp artery embolization has cast extrusion risk. Therefore, scalp infection should be considered because it may preclude additional surgical procedures.
Kaichi, Yoko; Kakeda, Shingo; Korogi, Yukunori; Nezu, Tomohisa; Aoki, Shiro; Matsumoto, Masayasu; Iida, Makoto; Awai, Kazuo
2015-01-01
Cerebral air embolism can be easily identified on computed tomography (CT) scans. However, changes in the distribution and amount of intracranial air are not well known. We report two patients with cerebral air embolism and present imaging findings on the serial changes in the intracranial air. We thought that the embolic source was venous in one patient because CT showed air inflow in cortical veins in the bilateral frontal areas, reflecting air buoyancy. In the other patient, CT showed air inflow into not only the cortical veins but also the bilateral cerebral hemispheres and we thought this to be a paradoxical cerebral air embolism. We found that intracranial air can be promptly absorbed and while cerebral infarcts due to air are clearly visualized on diffusion-weighted images (DWI), the air may rapidly disappear from images. In patients with suspected cerebral air embolism whose CT findings show no intracranial air, DWI should be performed because it may reveal cerebral infarction due to cerebral air embolism. PMID:26640730
Further evidence of gaseous embolic material in patients with artificial heart valves.
Georgiadis, D; Baumgartner, R W; Karatschai, R; Lindner, A; Zerkowski, H R
1998-04-01
We undertook this study to evaluate the hypothesis that most microemboli signals in patients with artificial heart valves are gaseous, assuming that microemboli counts in cerebral arteries would progressively decline with increasing distance from the generating heart valve. A total of 10 outpatients with CarboMedics (Sulzer Carbomedics Inc., n = 5) and ATS prosthetic heart valves (n = 5) in the aortic (n = 8), mitral (n = 1), or both aortic and mitral positions (n = 1) were recruited. Monitoring was performed simultaneously over the middle and anterior cerebral arteries and the common carotid artery for 30 minutes with the 2 MHZ transducers of a color duplex scanner (common carotid artery) and pulsed-wave Doppler ultrasonography (intracranial arteries). All data were harvested in an eight-channel digital audio tape recorder, and microembolic signal counts were evaluated online by two separate observers. Significantly higher microembolic signal counts were recorded in the common carotid artery (112 [75 to 175]) compared with the middle and anterior cerebral arteries (30 [18 to 36], p < 0.0001). Interobserver variability was satisfactory (k = 0.81). Our results strongly argue for gaseous underlying embolic material in patients with artificial heart valves because bubbles are bound to implode with time.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kuhara, Asako, E-mail: kuhara-asako@med.kurume-u.ac.jp; Tanaka, Norimitsu; Koganemaru, Masamichi
Management of arteriovenous malformations (AVMs) is challenging, and there is no consensus regarding either the ideal approach or the treatment timing. Percutaneous embolization is the most frequent approach currently used and is considered the first-line technique for AVMs. There is an ongoing discussion about the best technical approach to embolize AVMs. AVMs associated with a dominant outflow vein (DOV) are rare. Embolization of both the DOV and the nidus is considered more effective. Herein, we report a novel technique of transvenous embolization of a DOV under negative pressure from an arterial balloon catheter in a case of a peripheral AVM.more » This technique allows the embolization of the DOV and the nidus retrogradely.« less
[METABOLIC PREVENTION OF FAT EMBOLISM.
Yakovlev, A Yu; Pevnev, A A; Nikol'skiy, V O; Galanina, T A; Prokin, E G; Kalachev, S A; Ryabikov, D V
2016-07-01
to study the effect of solution with methionine "Remaxol" on metabolic disorders andfat embolism developing in severe combined trauma. 544 patient with severe skeletal trauma were undergone to a prospective study of dynamics of fat embolism syndrome development depending on the inclusion in the program of infusion therapy drug "Remaxol". The dynamics of lactate, glucose, free fatty acids, globularia and the incidence offat embolism syndrome were analyzed. Corrective action drug with methionine "Remaxol" on hyperglycemia, hyperlactatemia, hyperlipemia and de- crease circulation offat globules, which is reflected in the decrease in the frequency of development offat embolism syndrome was identified. One of the proposed mechanisms reduce the risk offat embolism development is assumed restoration of endogenous carnitine synthesis with methionine and transport offree fatty acids in the cell and their subsequent inclusion in metabolic processes.
[Diagnosis of lung embolism. Prospective study].
Melcher, G A; Frauchiger, B; Brunner, W; Nager, F
1987-01-31
In a prospective study over the years 1983-1985, 300 cases of acute pulmonary embolism were analyzed in relation to predisposing factors, clinical signs, arterial blood gas analysis and isotope perfusion scanning. Comparison of this prospective study with an earlier retrospective one showed similar results, with the exception of isotope scanning, an investigation which has gained increasing diagnostic reliability (highly suggestive results in 94% of patients with massive pulmonary embolism and in 64% with submassive pulmonary embolism). In two thirds of the cases the diagnosis was established during the first day after hospitalisation. In 10% of the patients pulmonary embolism occurred despite anticoagulant therapy.
Suicide by Intentional Air embolism.
Simon, Gábor; Rácz, Evelin; Mayer, Mátyás; Heckmann, Veronika; Tóth, Dénes; Kozma, Zsolt
2017-05-01
Venous air embolism occurs when air enters the venous system. The main causes of venous air embolism include medical procedures, neck and head trauma, and injuries of the genitals. Self-induced suicidal (and intentional) air embolism is extremely rare. The authors report a rare case of a suicidal air embolism committed using a self-made tool composed of a plastic bottle and an infusion set, injecting nearly 2000 mL of air into the cubital vein. The toxicological analysis suggested that midazolam, together with air, was also injected into the circulation using the same bottle and infusion set. © 2016 American Academy of Forensic Sciences.
Shammas, Nicolas W
2017-06-01
Distal embolization is a common occurrence with peripheral arterial interventions and is more frequent with the use of atherectomy devices. We report the first case of JetStream atherectomy (Boston Scientific, Maple Grove, MN) with the use of the novel WIRION embolic protection system filter. The procedure was performed successfully with no distal embolizations beyond the filter and with no complications in the delivery or retrieval of the filter. The pros and cons of the off label use of this filter with JetStream atherectomy are discussed.
Percutaneous Direct Puncture Embolization with N-butyl-cyanoacrylate for High-flow Priapism
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tokue, Hiroyuki, E-mail: tokue@s2.dion.ne.jp; Shibuya, Kei; Ueno, Hiroyuki
There are many treatment options in high-flow priapism. Those mentioned most often are watchful waiting, Doppler-guided compression, endovascular highly selective embolization, and surgery. We present a case of high-flow priapism in a 57-year-old man treated by percutaneous direct puncture embolization of a post-traumatic left cavernosal arteriovenous fistula using N-butyl-cyanoacrylate. Erectile function was preserved during a 12-month follow-up. No patients with percutaneous direct puncture embolization for high-flow priapism have been reported previously. Percutaneous direct puncture embolization is a potentially useful and safe method for management of high-flow priapism.
Ladner, Travis R; He, Lucy; Davis, Brandon J; Yang, George L; Wanna, George B; Mocco, J
2016-06-01
OBJECT Paragangliomas are highly vascular head and neck tumors for which preoperative embolization is often considered to facilitate resection. The authors evaluated their initial experience using a dual-lumen balloon to facilitate preoperative embolization in 5 consecutive patients who underwent preoperative transarterial Onyx embolization assisted by the Scepter dual-lumen balloon catheter between 2012 and 2014. OBJECT The authors reviewed the demographic and clinical records of 5 patients who underwent Scepter-assisted Onyx embolization of a paraganglioma followed by resection between 2012 and 2014. Descriptive statistics of clinical outcomes were assessed. RESULTS Five patients (4 with a jugular and 1 with a vagal paraganglioma) were identified. Three paragangliomas were embolized in a single session, and each of the other 2 were completed in 3 staged sessions. The mean volume of Onyx used was 14.3 ml (range 6-30 ml). Twenty-seven vessels were selectively catheterized for embolization. All patients required selective embolization via multiple vessels. Two patients required sacrifice of parent vessels (1 petrocavernous internal carotid artery and 1 vertebral artery) after successful balloon test occlusion. One patient underwent embolization with Onyx-18 alone, 2 with Onyx-34 alone, and 1 with Onyx-18 and -34. In each case, migration of Onyx was achieved within the tumor parenchyma. The mean time between embolization and resection was 3.8 days (range 1-8 days). Gross-total resection was achieved in 3 (60%) patients, and the other 2 patients had minimal residual tumor. The mean estimated blood loss during the resections was 556 ml (range 200-850 ml). The mean postoperative hematocrit level change was -17.3%. Two patients required blood transfusions. One patient, who underwent extensive tumor penetration with Onyx, developed a temporary partial cranial nerve VII palsy that resolved to House-Brackmann Grade I (out of VI) at the 6-month follow-up. One patient experienced improvement in existing facial nerve weakness after embolization. CONCLUSIONS Scepter catheter-based Onyx embolization seems to be safe and effective. It was associated with excellent distal tumor vasculature penetration and holds promise as an adjunct to conventional transarterial Onyx embolization of paragangliomas. However, the ease of tumor penetration should encourage caution in practitioners who may be able to effect comparable improvement in blood loss with more conservative proximal Onyx penetration.
Ribé, L; Bicknell, C D; Gibbs, R G; Burfitt, N; Jenkins, M P; Cheshire, N; Hamady, M
2017-06-01
Purpose The aim of this paper is to report our experience of type II endoleak treatment after endovascular aneurysm repair with intra-arterial injection of the embolizing liquid material, Onyx liquid embolic system. Methods From 2005 to 2012, we performed a retrospective review of 600 patients, who underwent endovascular repair of an abdominal aortic aneurysm. During this period, 18 patients were treated with Onyx for type II endoleaks. Principal findings The source of the endoleak was the internal iliac artery in seven cases, inferior mesenteric artery in seven cases and lumbar arteries in four cases. Immediate technical success was achieved in all patients and no endoleak from the treated vessel recurred. During a mean follow-up of 19 months, no major morbidity or mortality occurred, and one-year survival was 100%. Conclusions Treatment of type II endoleaks with Onyx is safe and effective over a significant time period.
Covered stent to exclude intravascular thrombus.
Liistro, Francesco; Stankovic, Goran; Di Mario, Carlo; Montorfano, Matteo; Briguori, Carlo; Colombo, Antonio
2002-04-01
To describe the utility of stent-graft implantation to avoid distal embolization from a large thrombus-containing lesion. A 67-year-old man was evaluated for recent onset of disabling left leg claudication. Angiography disclosed a mobile lobular mass occluding the left common iliac artery; irregular staining suggested an atherothrombotic lesion. Through a percutaneous ipsilateral access and an 8-F sheath, a balloon-expandable Jostent peripheral stent-graft was positioned with the distal edge immediately proximal to the internal iliac artery ostium. A prominent "waist" at the center of the balloon confirmed entrapment of the thrombotic mass. Completion angiography showed an optimal result with no residual stenosis or evidence of distal embolization. At 6-month follow-up, the patient was asymptomatic with angiographically documented luminal patency and no evidence of in-stent stenosis. Stent-graft implantation appears a viable treatment alternative for thrombus-containing lesions, particularly when the thrombotic material is localized or is in a large vessel.
J-C. Domec; F.G. Scholz; S.J. Bucci; F.C. Meinzer; G. Goldstein; R. Villalobos-Vega
2006-01-01
Vulnerability to water-stress-induced embolism and variation in the degree of native embolism were measured in lateral roots of four co-occuring neotropical savanna tree species. Root embolism varied diurnally and seasonally. Late in the dry season, loss of root xylem conductivity reached 80% in the afternoon when root water potential (ψroot...
Microfabricated therapeutic actuators
Lee, Abraham P.; Northrup, M. Allen; Ciarlo, Dino R.; Krulevitch, Peter A.; Benett, William J.
1999-01-01
Microfabricated therapeutic actuators are fabricated using a shape memory polymer (SMP), a polyurethane-based material that undergoes a phase transformation at a specified temperature (Tg). At a temperature above temperature Tg material is soft and can be easily reshaped into another configuration. As the temperature is lowered below temperature Tg the new shape is fixed and locked in as long as the material stays below temperature Tg. Upon reheating the material to a temperature above Tg, the material will return to its original shape. By the use of such SMP material, SMP microtubing can be used as a release actuator for the delivery of embolic coils through catheters into aneurysms, for example. The microtubing can be manufactured in various sizes and the phase change temperature Tg is determinate for an intended temperature target and intended use.
Microfabricated therapeutic actuators
Lee, A.P.; Northrup, M.A.; Ciarlo, D.R.; Krulevitch, P.A.; Benett, W.J.
1999-06-15
Microfabricated therapeutic actuators are fabricated using a shape memory polymer (SMP), a polyurethane-based material that undergoes a phase transformation at a specified temperature (Tg). At a temperature above temperature Tg material is soft and can be easily reshaped into another configuration. As the temperature is lowered below temperature Tg the new shape is fixed and locked in as long as the material stays below temperature Tg. Upon reheating the material to a temperature above Tg, the material will return to its original shape. By the use of such SMP material, SMP microtubing can be used as a release actuator for the delivery of embolic coils through catheters into aneurysms, for example. The microtubing can be manufactured in various sizes and the phase change temperature Tg is determinate for an intended temperature target and intended use. 8 figs.
Ambulatory vital signs in the workup of pulmonary embolism using a standardized 3-minute walk test.
Amin, Qamar; Perry, Jeffrey J; Stiell, Ian G; Mohapatra, Subhra; Alsadoon, Abdulaziz; Rodger, Marc
2015-05-01
Diagnosing pulmonary embolism can be difficult given its highly variable clinical presentation. Our objective was to determine whether a decrease in oxygen saturation or an increase in heart rate while ambulating could be used as an objective tool in the diagnosis of pulmonary embolism. This was a two-site tertiary-care-centre prospective cohort study that enrolled adult emergency department or thrombosis clinic patients with suspected or newly confirmed pulmonary embolism. Patients were asked to participate in a standardized 3-minute walk test, which assessed ambulatory heart rate and ambulatory oxygen saturation. The primary outcome was pulmonary embolism. We enrolled 114 patients, including 30 with pulmonary embolism (26.3%). A ≥2% absolute decrease in ambulatory oxygen saturation and an ambulatory change in heart rate >10 beats per minute (BPM) were significantly associated with pulmonary embolism. An ambulatory heart rate change of >10 BPM had a sensitivity of 96.6% (95% confidence interval [CI] 83.3 to 99.4) and a specificity of 31.0% (95% CI 22.1 to 45.0) for pulmonary embolism. A ≥2% absolute decrease ambulatory oxygen saturation had a sensitivity of 80.2% (95% CI 62.7 to 90.5) and a specificity of 39.3% (95% CI 29.5 to 50.0) for pulmonary embolism. The combination of both variables yielded a sensitivity of 100.0% (95% CI 87.0 to 100.0) and a specificity of 11.0% (95% CI 6.6 to 21.0). In summary, our study found that an ambulatory heart rate change of >10 BPM or a ≥2% absolute decrease in ambulatory oxygen saturation from baseline during a standardized 3-minute walk test are highly correlated with pulmonary embolism. Although the findings appear promising, neither of these variables can currently be recommended as a screening tool for pulmonary embolism until larger prospective studies examine their performance either alone or with pre-existing rules.
Emergency transcatheter arterial embolization for massive gastrointestinal arterial hemorrhage.
Shi, Zhong Xing; Yang, Jing; Liang, Hong Wei; Cai, Zhen Hua; Bai, Bin
2017-12-01
To evaluate the different arteriographic manifestations of acute arterial massive hemorrhage of the gastrointestinal (GI) tract and the efficacy of emergency transcatheter arterial embolization (ETAE).A total of 88 patients with acute massive GI bleeding who experienced failure of initial endoscopy and/or conservative treatment were referred to our interventional department for acute GI arteriography from January 2007 to June 2015. After locating the source of bleeding, appropriate embolic agents, such as spring coil, hydroxyl methyl acrylic acid gelatin microspheres, polyvinyl alcohol (PVA) particles, etc., were used to embolize the targeted vessels. The angiographic manifestations and the effects of embolization of acute arterial massive hemorrhage of the GI tract were retrospectively analyzed.Of the 88 patients, 54 were diagnosed with arterial hemorrhage of the upper GI tract and 34 with arterial hemorrhage of the lower GI tract. Eighty cases were associated with positive angiography, which showed the following: contrast extravasation (only); gastroduodenal artery stenosis; pseudoaneurysm (only); pseudoaneurysm rupture with contrast extravasation; pseudoaneurysms merged with intestinal artery stenosis; GI angiodysplasia; and tumor vascular bleeding. Eight cases were diagnosed with negative angiography. Seven-two patients underwent successful hemostasis, and a total of 81 arteries were embolized. The technical and clinical success rates (no rebleeding within 30 days) in performing transcatheter embolization on patients with active bleeding were 100% and 84.71%, respectively (72 of 85). Within 30 days, the postoperative rebleeding rate was 15.29% (13/85). Of these rebleeding cases, 2 patients were formerly treated with "blind embolization," 7 underwent interventional embolic retreatment, and 3 had surgical operations. All cases were followed-up for 1 month, and 3 patients died from multiple organ failure. No serious complications such as bowel ischemia necrosis were observed.ETAE is a safe, effective, and minimally invasive treatment; because of the diversified arteriographic manifestations of acute GI hemorrhage, the proper selection of embolic agents and the choice of reasonable embolization method are essential for successful hemostasis. Copyright © 2017 The Authors. Published by Wolters Kluwer Health, Inc. All rights reserved.
Barber, Sean M; Rangel-Castilla, Leonardo; Zhang, Y Jonathan; Klucznik, Richard; Diaz, Orlando
2015-10-01
Endovascular therapy is the preferred treatment for most carotid-cavernous fistulas (CCFs). Early reports have documented excellent initial clinical and radiographic outcomes after embolization of CCFs with Onyx or n-butyl cyanoacrylate (n-BCA), but little evidence is available about the long-term durability of this technique. To characterize the long-term durability of CCF liquid embolization. The authors retrospectively reviewed a database of 24 CCFs in 21 consecutive patients who underwent Onyx or n-BCA embolization of a CCF from 2006 to 2013 at our institution. A total of 25 Onyx or n-BCA embolization procedures were attempted and 24 successfully completed during the study, resulting in complete or near-complete occlusion by the end of the study in all 24 CCFs (obliteration success, 100%). Attempted embolization in a single CCF failed initially, but was performed successfully at a later date by a different approach. None of the 24 CCFs recanalized, regrew, or required any further treatment subsequent to Onyx or n-BCA embolization throughout a mean 12.4 months of angiographic follow-up (range 1-36 months). Clinically significant complications were seen in three embolization procedures, including cranial nerve palsies (n=1), embolic infarct (n=1), and intraperitoneal hemorrhage (n=1). Early evidence has indicated that endovascular embolization with Onyx is relatively safe and effective at achieving an initial angiographic cure for CCFs. Results of our series suggest that angiographic and clinical outcomes of Onyx and n-BCA embolization remain stable at mid- and long-term follow-up. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Griessenauer, Christoph J; He, Lucy; Salem, Mohamed; Chua, Michelle H; Ogilvy, Christopher S; Thomas, Ajith J
2016-09-01
Curative transarterial embolization of noncavernous sinus dural arteriovenous fistulas (dAVFs) is challenging. We sought to evaluate the role of the middle meningeal artery (MMA) in endovascular treatment of these lesions. We performed a retrospective cohort study on patients who underwent transarterial Onyx embolization of a noncavernous sinus dAVFs with contribution from the MMA at a major academic institution in the United States from January 2009 to January 2015. Twenty consecutive patients who underwent transarterial Onyx embolization of a noncavernous sinus dAVF were identified. One patient was excluded as there was no MMA contribution to the dAVF. All of the remaining 19 patients (61.3 ± 13.8 years of age) underwent transarterial embolization through the MMA. Six patients (31.6%) presented with intraparenchymal or subarachnoid hemorrhage from the dAVF. The overall angiographic cure rate was 73.7% upon last follow up. In 71.4% of successfully treated patients transarterial embolization of the MMA alone was sufficient to achieve angiographic cure. When robust MMA supply was present, MMA embolization resulted in angiographic cure even after embolization of other arterial feeders had failed in 92.9% of patients. A robust contribution of the MMA to the fistula was the single most important predictor for successful embolization (P = 0.00129). We attribute our findings to the fairly straight, non-tortuous course of the MMA that facilitates microcatheter access, navigation, and Onyx penetration. Noncavernous sinus dAVF can be successfully embolized with transarterial Onyx through the MMA, as long as supply is robust. A transvenous approach is rarely necessary. Clin. Anat. 29:718-728, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
Seizures after Onyx Embolization for the Treatment of Cerebral Arteriovenous Malformation
de los Reyes, K.; Patel, A.; Doshi, A.; Egorova, N.; Panov, F.; Bederson, J.B.; Frontera, J.A.
2011-01-01
Summary Onyx embolization of cerebral arteriovenous malformations (AVM) has become increasingly common. We explored the risk of seizures after Onyx use. A retrospective review was conducted of 20 patients with supratentorial brain arteriovenous malformation (AVM) who received Onyx embolization between 2006 and 2009. Baseline demographics, clinical history, seizure history, AVM characteristics and treatment were compared between those who developed post-onyx seizure and those who did not. MRIs were reviewed for edema following Onyx treatment. Of 20 patients who underwent Onyx embolization, the initial AVM presentation was hemorrhage in 40% (N=8). The median number of embolizations was two (range 1-4) and the median final obliteration amount was 90% (range 50-100%). A history of seizure was present in 50% (N=10) of patients pre-embolization and 12 (60%) patients received seizure medications (treatment or prophylaxis) prior to embolization. Seizur post-Onyx embolization occurred in 45% (N=9). The median time to seizur post-Onyx was seven days (range 0.3-210). Four patients (20%) with seizures post-Onyx had no seizure history. Two of these patients (10%) had no other identifiable cause for seizure other than recent Onyx embolization. Seizures in these two patients occurred within 24 hours of Onyx administration. Among patients with post-Onyx seizures, there was a trend toward larger AVM size (P=0.091) and lower percent obliteration (P=0.062). Peri-AVM edema was present in 75% of MRIs performed within one month of Onyx treatment and may represent a possible etiology for seizures. New onset seizures post-Onyx embolization are not uncommon. Further study of seizure prevention is warranted. PMID:22005695
Luzzi, Sabino; Del Maestro, Mattia; Bongetta, Daniele; Zoia, Cesare; Giordano, Aldo V; Trovarelli, Donatella; Raysi Dehcordi, Sohelia; Galzio, Renato J
2018-05-09
Grade III Spetzler-Martin brain arteriovenous malformations (AVMs) are a specific set of AVMs with high variability in terms of site, size, angioarchitecture, flow dynamics, and involvement of eloquent areas. Surgery preceded by preoperative embolization has been reported as a useful treatment option for these lesions. The aim of this study is to report outcomes and personal experience of combined preoperative Onyx embolization and surgical resection on a consecutive series of grade III brain AVMs. Between 2005 and 2017, 27 grade III AVMs were treated by means of a staged Onyx embolization and subsequent surgical treatment. Site and size of the AVMs, embolization, and surgical specifics as well as complications and outcomes were retrospectively reviewed. All AVMs were supratentorial, 13 of which were hemorrhagic. Mean nidal volume was 19.5 mL. Average embolization sessions were 1.6. Mean embolization-related obliteration rate and morbidity were 28.8% and 3.7%, respectively. Surgery was performed within 3.7 days on average. In our experience, Onyx embolization made the nidus excision easier, facilitated the hemostasis, and contributed to the early identification of the lesion in cases of small or racemose nidus. The surgical obliteration rate was 92.6%. A good overall outcome (modified Rankin Scale score 0-2) was achieved in 70.4% of patients. In our experience, preoperative Onyx embolization helped the surgical management of grade III Spetzler-Martin brain AVMs. Careful evaluation of the angioarchitecture, a tailored strategy in the embolization process, and full cooperation within the neurosurgical-neuroendovascular team are mandatory. Copyright © 2018 Elsevier Inc. All rights reserved.
Neri, Margherita; Riezzo, Irene; Dambrosio, Michele; Pomara, Cristoforo; Turillazzi, Emanuela; Fineschi, Vittorio
2010-10-10
Fat embolization following major trauma is reported to be a quite common event, while the clinical fat embolism syndrome (FES) seems to be a much rarer event. Fat embolism occurs in 2 up to 23% of patients with isolated femoral shaft fractures. This complication appears to be related not only to the fracture, but also to the timing of stabilization. Sometimes it may be impossible to perform histochemical reactions on frozen sections to detect fat emboli thus confirming diagnosis or suspicion of FES. The finding of fibrinogen and platelets around the apparently empty spaces in the blood vessels has been proposed as an evidence for vital reaction due to either a vital cellular reaction or a flotation mechanism, thus supporting an intravital fat embolism. We report a fatal case due to fat embolism syndrome in a young man hospitalized for a right femoral neck fracture, treated with orthopaedic surgery and subjected to an intra-surgery transesophageal echocardiography that revealed embolization of numerous highly echogenic bodies. Four hours after the onset of clinical symptoms the man died from respiratory failure. The autopsy confirmed the clinical diagnosis of fat embolism syndrome. The histological examination revealed a large amount of fat globules in cerebral and pulmonary arteries and in glomerular capillaries, as well as fibrin and platelet deposition confirmed by the positive results by Sudan III staining for lipids and immunohistochemistry with anti-CD61 and anti-fibrinogen antibodies. The quantitative classification of fat embolism was grade 3 of Sevitt's classification or grade 4 of Fineschi's quantification, according to the current quantitative microscopic methods used for grading fat embolism in pulmonary tissue. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.
Herial, Nabeel A; Khan, Asif A; Sherr, Gregory T; Qureshi, Mushtaq H; Suri, M Fareed K; Qureshi, Adnan I
2015-09-01
The US Food and Drug Administration recently approved a detachable-tip microcatheter, the Apollo microcatheter (eV3, Inc, Irvine, California), to prevent catheter entrapment during embolization of brain arteriovenous malformations (AVMs) using liquid embolic systems. To report technical aspects and clinical results of cerebral embolizations with the Apollo microcatheter in 7 embolizations in 3 adult patients. A 62-year-old man presented with an AVM in the parieto-occipital region measuring 3.6 × 1.6 cm with major cortical feeders from the right middle cerebral artery (MCA) and minor contribution from the distal right anterior cerebral artery. Two pedicles originating from the MCA were embolized. A 48-year-old woman presented with a left frontal AVM measuring 3.3 × 1.8 cm with arterial feeders from the left MCA, left middle meningeal artery, and contralateral anterior cerebral artery. Three pedicles originating from the left MCA were embolized. A 76-year-old man presented with an arteriovenous fistula with multiple fistulous connections and feeders from both vertebral and occipital arteries and the left posterior cerebral artery draining into the left transverse, torcula, and left sigmoid sinus. Two major occipital artery feeders were embolized. Seven Apollo microcatheters were used with the Onyx 18 liquid embolic system. The length of the detachable tip was 15 mm in 2 and 30 mm in 5 embolizations. The mean microcatheter in-position time within the pedicle was 20 minutes. Detachment of tip occurred in 3 instances. No limitations in accessing target arterial feeders and safe tip disengagement were noted despite prolonged injection times. Our initial experience supports the feasibility, safety, and effectiveness of detachable-tip microcatheters in treating brain AVMs and arteriovenous fistulas.
Gao, Michael; Gemmete, Joseph J; Chaudhary, Neeraj; Pandey, Aditya S; Sullivan, Steven E; McKean, Erin L; Marentette, Lawerence J
2013-09-01
Juvenile nasopharyngeal angiofibromas (JNAs) are hypervascular tumors that may benefit from preoperative devascularization to reduce intraoperative blood loss (IBL). The purpose of this study was to compare transarterial particulate embolization (TAPE) with the direct percutaneous embolization (DPE) technique using ethylene vinyl alcohol (Onyx, ev3, Irvine, CA) for the preoperative devascularization of a JNA. We retrospectively reviewed 50 consecutive JNA resections since 1995 for which preoperative embolization was either transarterial with particulate material (n = 39) or DPE (n = 11) using only Onyx. The IBL, transfusion requirements, operative time, and length of hospital admission were compared between the two groups. The mean IBL was 1,348.7 ± 932.2 mL particulate group, 569.1 ± 700.7 mL Onyx group (one-tailed Student's t test p = 0.003). The mean unit of packed red blood cells was 1.56 ± 2.01 units particulate group, 0.45 ± 1.04 units Onyx group (p = 0.009). The relationship between embolization type and IBL remained significant or strongly correlated when accounting for the Fisch stage of the tumor (p = 0.010 and p = 0.056, respectively, by a multivariate least squares fit; alternately p = 0.0003 and p = 0.023, respectively, in the subset of patients with Fisch stage III tumors only). We also found that the proportion of resections for which an endoscopic approach could be used was significantly higher in the Onyx group than the particulate group (81.8 and 18.2 %; Pearson p = 0.0002), and this was also significant both in our multivariate nominal logistic fit (p < 0.001) and in the subset of patients with Fisch stage III tumors (p = 0.018). Pre-operative DPE with Onyx of a JNA when compared to TAPE significantly decreased IBL and RBC transfusion requirement during surgical resection. The proportion of surgical resections performed from an endoscopic approach was higher in the DPE Onyx group, which may have affected the results.
Myocardial Infarction as a Complication of Bronchial Artery Embolization
DOE Office of Scientific and Technical Information (OSTI.GOV)
Labbé, Hugo, E-mail: hugo.labbe.1@ulaval.ca; Bordeleau, Simon; Drouin, Christine
Bronchial artery embolization is now a common treatment for massive pulmonary hemoptysis if flexible bronchoscopy at the bedside failed to control the bleeding. Complications of this technique range from benign chest pain to devastating neurological impairments. We report the case of a 41-year-old man who developed an ST elevation myocardial infarction during bronchial artery embolization, presumably because of coronary embolism by injected particles. In this patient who had no previously known coronary artery disease, we retrospectively found a communication between the left bronchial artery and the circumflex coronary artery. This fistula was not visible on the initial angiographic view andmore » likely opened because of the hemodynamic changes resulting from the embolization. This case advocates for careful search for bronchial-to-coronary arterial fistulas and the need for repeated angiographic views during embolization procedures.« less
Arterial and venous embolization: Declotting of dialysis shunts by direct injection of streptokinase
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zeit, R.M.
1986-06-01
During the past 33 months, thrombolysis of 79 clotted hemodialysis shunts was attempted by injecting small quantities of dilute streptokinase solution directly into the clotted shunt, followed by massage of the clot. Embolization of clot fragments in six of 79 cases (7.6%) was demonstrated angiographically. In four of the six cases embolization involved the brachial artery or its branches. In one case embolization involved an arm vein, and in one case embolization involved both the bracial artery and axillary vein. All patients remained asymptomatic, and repeat angiographic study, usually performed the following day, showed resolution of the emboli in fourmore » of five cases. The incidence of embolization in direct-injection thrombolysis reported in this study appears to be comparable to that reported in studies using the streptokinase infusion technique.« less
Tanaka, Keiko; Koizumi, Toshimitsu; Higa, Takeru; Imai, Noriaki
2016-11-01
Preoperative uterine artery embolization has been shown to help reduce blood loss, with few complications. Most reports indicated that uterine artery embolization is safe for uterine fibrosis; the occurrence of hyperkalemia and acute kidney failure as complications of preoperative uterine artery embolization has not been reported previously. Here we report the occurrence of hyperkalemia and acute kidney failure after preoperative uterine artery embolization for a large uterine fibroid. To the best of our knowledge, this is the first report on the occurrence of hyperkalemia and acute kidney failure after preoperative uterine artery embolization. A 48-year-old Japanese woman presented to our hospital complaining of compression in her abdomen and an abdominal mass. Magnetic resonance imaging showed a large uterine fibroid measuring 37.5×27×13.5 cm. Therefore, we planned preoperative uterine artery embolization to help reduce blood loss. However, hyperkalemia and acute kidney failure occurred owing to the development of necrotic tissue after uterine artery embolization; therefore, emergency total abdominal hysterectomy and bilateral salpingo-oophorectomy were performed. She experienced 105 g of blood loss intraoperatively. The weight of her uterus was 10.8 kg and the volume was 9964 cm 3 , with extensive necrotic tissue. Her hyperkalemia and kidney failure resolved after the surgery. We reported the occurrence of serious complications, including hyperkalemia and acute kidney failure, after preoperative uterine artery embolization for a large uterine fibroid.
Zandrino, F; Tettoni, S M; Gallesio, I; Summa, M
2017-01-01
The goal of this study was to retrospectively assess the efficacy of emergency percutaneous transcatheter arterial embolization in patients with severe bleeding due to upper gastrointestinal or jejunal tumor. Twelve patients (7 men, 5 women; mean age, 74 years±14 (SD); range: 54-86 years) with severe bleeding from the upper gastrointestinal tract, with failed endoscopic treatment not eligible for emergency surgery were treated by emergency percutaneous transcatheter arterial embolization. The bleeding cause was gastric tumor in 7 patients, duodenal tumor in 4 patients and jejunal tumor in one patient. Procedure details and follow-up were reviewed. Twelve embolization procedures were performed using various embolic agents. Embolization was achieved and bleeding was stopped in all patients. Five patients underwent surgery within the 30 days following embolization. In the remaining 7 patients, no bleeding occurred at 1 month follow-up in 6 patients and bleeding recurred in one patient at 1 month. In this later patient, endoscopic treatment was successful. The results of our study suggest that transcatheter arterial embolization is safe and effective in patients with severe arterial bleeding due to upper gastrointestinal or jejunal tumor. In some patients, transcatheter arterial embolization can be used as a bridge to surgery. Copyright © 2016 Éditions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.
Recurrent Hemarthrosis due to Iatrogenic AVF Treated With Onyx Embolization.
Koleilat, Issam; Phair, John
2017-07-01
A 78-year-old gentleman presented with recurrent symptomatic hemarthrosis after total knee arthroplasty. His workup revealed an iatrogenic arteriovenous fistula (iAVF). The iAVF was embolized with the Onyx Liquid Embolization System with resolution of his symptoms up to 10 months of follow-up. This is the first description to our knowledge of an iatrogenic hemarthrosis after total knee arthroplasty successfully treated with Onyx solution embolization.
Evaluation of meteorological and epidemiological characteristics of fatal pulmonary embolism
NASA Astrophysics Data System (ADS)
Törő, Klára; Pongrácz, Rita; Bartholy, Judit; Váradi-T, Aletta; Marcsa, Boglárka; Szilágyi, Brigitta; Lovas, Attila; Dunay, György; Sótonyi, Péter
2016-03-01
The objective of the present study was to identify risk factors among epidemiological factors and meteorological conditions in connection with fatal pulmonary embolism. Information was collected from forensic autopsy records in sudden unexpected death cases where pulmonary embolism was the exact cause of death between 2001 and 2010 in Budapest. Meteorological parameters were detected during the investigated period. Gender, age, manner of death, cause of death, place of death, post-mortem pathomorphological changes and daily meteorological conditions (i.e. daily mean temperature and atmospheric pressure) were examined. We detected that the number of registered pulmonary embolism (No 467, 211 male) follows power law in time regardless of the manner of death. We first described that the number of registered fatal pulmonary embolism up to the nth day can be expressed as Y( n) = α ṡ n β where Y denotes the number of fatal pulmonary embolisms up to the nth day and α > 0 and β > 1 are model parameters. We found that there is a definite link between the cold temperature and the increasing incidence of fatal pulmonary embolism. Cold temperature and the change of air pressure appear to be predisposing factors for fatal pulmonary embolism. Meteorological parameters should have provided additional information about the predisposing factors of thromboembolism.
Facial Palsy Following Embolization of a Juvenile Nasopharyngeal Angiofibroma.
Tawfik, Kareem O; Harmon, Jeffrey J; Walters, Zoe; Samy, Ravi; de Alarcon, Alessandro; Stevens, Shawn M; Abruzzo, Todd
2018-05-01
To describe a case of the rare complication of facial palsy following preoperative embolization of a juvenile nasopharyngeal angiofibroma (JNA). To illustrate the vascular supply to the facial nerve and as a result, highlight the etiology of the facial nerve palsy. The angiography and magnetic resonance (MR) imaging of a case of facial palsy following preoperative embolization of a JNA is reviewed. A 13-year-old male developed left-sided facial palsy following preoperative embolization of a left-sided JNA. Evaluation of MR imaging studies and retrospective review of the angiographic data suggested errant embolization of particles into the petrosquamosal branch of the middle meningeal artery (MMA), a branch of the internal maxillary artery (IMA), through collateral vasculature. The petrosquamosal branch of the MMA is the predominant blood supply to the facial nerve in the facial canal. The facial palsy resolved since complete infarction of the nerve was likely prevented by collateral blood supply from the stylomastoid artery. Facial palsy is a potential complication of embolization of the IMA, a branch of the external carotid artery (ECA). This is secondary to ischemia of the facial nerve due to embolization of its vascular supply. Clinicians should be aware of this potential complication and counsel patients accordingly prior to embolization for JNA.
Cerebral fat embolism and the "starfield" pattern: a case report.
Aravapalli, Amit; Fox, James; Lazaridis, Christos
2009-11-19
Nearly all long-bone fractures are accompanied by some form of fat embolism. The rare complication of clinically significant fat embolism syndrome, however, occurs in only 0.9-2.2% of cases. The clinical triad of fat embolism syndrome consists of respiratory distress, altered mental status, and petechial rash. Cerebral fat embolism causes the neurologic involvement seen in fat embolism syndrome. A 19-year-old African-American male was admitted with gunshot wounds to his right hand and right knee. He had diffuse hyperactive deep tendon reflexes, bilateral ankle clonus and decerebrate posturing with a Glasgow Coma Scale (GCS) score of 4T. Subsequent MRI of the brain showed innumerable punctate areas of restricted diffusion consistent with "starfield" pattern. On a 10-week follow up he has a normal neurological examination and he is discharged home. Despite the severity of the neurologic insult upon initial presentation, the majority of case reports on cerebral fat embolism illustrate that cerebral dysfunction associated with cerebral fat embolism is reversible. When neurologic deterioration occurs in the non-head trauma patient, then a systemic cause such as fat emboli should be considered. We describe a patient with non-head trauma who demonstrated the classic "starfield" pattern on diffusion-weighted MRI imaging.
An, Tianzhi; Zhang, Shasha; Xu, Min; Zhou, Shi; Wang, Weiping
2015-01-01
Our objective was to review the technical success and clinical outcomes of transcatheter embolization of peripheral renal artery with FuAiLe medical glue (FAL). All patients who underwent FAL embolization for peripheral renal artery bleeding were retrospectively analyzed for underlying pathologies, technical success and outcome of embolization procedure. 14 consecutive patients underwent FAL embolization between November 2009 and February 2013. The causes of bleeding were post biopsy (n = 5), blunt trauma (n = 5), percutaneous lithotripsy of kidney stones (n = 3), and complication of cardiac catheterization (n = 1). Bleeding was effectively controlled with a single injection of FAL. Mean volume of FAL mixture (FAL:Lipiodol, 1:1) was 0.5 mL (range, 0.2–0.8 mL). No reflux of the embolic agent was noted. Average cost of FAL for each procedure was $74. Postembolization clinical follow-up showed no evidence of recurrent hematuria, progression of hematoma, hypertension, or elevation of serum creatinine. Doppler ultrasound examinations in 13 patients demonstrated no abscess, renal parenchyma infarction, or renal artery abnormalities. Superselective FAL embolization may be used for the treatment of active bleeding from peripheral renal arteries. It has a high success rate and is quicker and less expensive than embolization with other agents. PMID:25765607
An, Tianzhi; Zhang, Shasha; Xu, Min; Zhou, Shi; Wang, Weiping
2015-03-13
Our objective was to review the technical success and clinical outcomes of transcatheter embolization of peripheral renal artery with FuAiLe medical glue (FAL). All patients who underwent FAL embolization for peripheral renal artery bleeding were retrospectively analyzed for underlying pathologies, technical success and outcome of embolization procedure. 14 consecutive patients underwent FAL embolization between November 2009 and February 2013. The causes of bleeding were post biopsy (n = 5), blunt trauma (n = 5), percutaneous lithotripsy of kidney stones (n = 3), and complication of cardiac catheterization (n = 1). Bleeding was effectively controlled with a single injection of FAL. Mean volume of FAL mixture (FAL:Lipiodol, 1:1) was 0.5 mL (range, 0.2-0.8 mL). No reflux of the embolic agent was noted. Average cost of FAL for each procedure was $74. Postembolization clinical follow-up showed no evidence of recurrent hematuria, progression of hematoma, hypertension, or elevation of serum creatinine. Doppler ultrasound examinations in 13 patients demonstrated no abscess, renal parenchyma infarction, or renal artery abnormalities. Superselective FAL embolization may be used for the treatment of active bleeding from peripheral renal arteries. It has a high success rate and is quicker and less expensive than embolization with other agents.
Iwata, Tomonori; Mori, Takahisa; Tajiri, Hiroyuki; Miyazaki, Yuichi; Nakazaki, Masahito; Mizokami, Koji
2013-03-01
The transfemoral approach is a common technique for coil embolization of cerebral aneurysms in the anterior cerebral circulation. However, it is difficult to advance a guiding catheter into the carotid artery via the femoral route in patients with a tortuous aortic arch, an unfavorable supra-aortic takeoff, aortic diseases, or occlusion of the femoral artery. To report our initial experiences of coil embolization of cerebral aneurysms in the anterior cerebral circulation with a novel sheath guide for transbrachial carotid cannulation. A sheath guide designed specifically for transbrachial carotid cannulation was developed; transbrachial coil embolization for cerebral aneurysms began in May 2011. Included for analysis were patients who underwent transbrachial coil embolization for cerebral aneurysms in the anterior cerebral circulation from May 2011 to January 2012. Adjuvant techniques, angiographic results, procedural success, and periprocedural complications were investigated. Ten patients underwent transbrachial coil embolization of cerebral aneurysms in the anterior cerebral circulation. All procedures were successful using the brachial route. No periprocedural complications occurred. Patients were permitted to get seated immediately after coil embolization even during hemostasis. The sheath guide specifically designed for transbrachial carotid cannulation was useful for coil embolization of cerebral aneurysms in the anterior cerebral circulation.
A Preliminary Observation of Weight Loss Following Left Gastric Artery Embolization in Humans
Gunn, Andrew J.; Oklu, Rahmi
2014-01-01
Background/Objectives. Embolization of the left gastric artery (LGA), which preferentially supplies the gastric fundus, has been shown to produce weight loss in animal models. However, weight loss after LGA embolization in humans has not been previously established. The aim of this study was to evaluate postprocedural weight loss in patients following LGA embolization. Subjects/Methods. A retrospective analysis of the medical records of patients who underwent LGA embolization for upper gastrointestinal (GI) bleeding was performed. Postprocedural weight loss in this group was compared to a control group of patients who had undergone embolization of other arteries for upper GI bleeding. Results. The experimental group (N = 19) lost an average of 7.3% of their initial body weight within three months of LGA embolization, which was significantly greater than the 2% weight loss observed in the control group (N = 28) (P = 0.006). No significant differences were seen between the groups in preprocedural body mass index (BMI), age, postprocedural care in the intensive care unit, history of malignancy, serum creatinine, or left ventricular ejection fraction. Conclusions. The current data suggest that body weight in humans may be modulated via LGA embolization. Continued research is warranted with prospective studies to further investigate this phenomenon. PMID:25349724
Renal paradoxical embolism in a hypertensive young adult without acute ischemic symptoms.
Nara, Mizuho; Komatsuda, Atsushi; Fujishima, Masumi; Fujishima, Naohito; Nara, Miho; Iino, Takako; Ito, Hiroshi; Sawada, Ken-ichi; Wakui, Hideki
2011-08-01
A 22-year-old woman, who often carried heavy books, was admitted for evaluation of hyperreninemic hypertension. Two months prior to admission, she noted leg edema. Radiological examinations revealed bilateral renal infarction with no other abnormal findings. An echocardiography showed a patent foramen ovale (PFO). Hypertension was considered secondary to renal infarction caused by paradoxical embolism through PFO. Antihypertensive and anticoagulant therapy led to improvement of hypertension. In previously reported cases of renal paradoxical embolism, multiorgan involvement was usually observed. Our case is unique in that embolism was confirmed only in the kidneys, and that clinical characteristics of renal embolism were not observed.
Stagaman, D J; Presti, C; Rees, C; Miller, D D
1990-06-01
Right-sided valvular (tricuspid, pulmonic) endocarditis is frequently complicated by septic pulmonary embolization. Systemic embolization may also rarely occur due to associated left-sided endocarditis or right-to-left shunting in patients with septal defects. This report documents the occurrence of systemic embolization causing a cerebrovascular accident in an intravenous drug abuser with recurrent tricuspid valve endocarditis due to an isolated peripheral septic pulmonary arteriovenous fistula. Noninvasive diagnosis of the fistula by cardiac auscultation, contrast echocardiography, and nuclear magnetic resonance imaging was confirmed by selective pulmonary angiography. Subselective balloon embolization of the pulmonary arteries feeding this fistula was accomplished.
Dhar, Dinesh
2012-12-01
Nearly all patients following fractures of bones develop sub-clinical form of fat embolism but the classical form of fat embolism syndrome (FES) presents with triad of respiratory, neurologic and dermal manifestations. Non-traumatic conditions can also have fat embolism, but the incidence is very low. The diagnosis is mainly clinical supported by laboratory and radiological finding. Treatment is mainly supportive with early stabilization of fractured bones. In most cases, prognosis is good if the condition is detected and treated early. High index of suspicion in polytrauma patient is the key to early diagnosis of this condition. This report describes two cases of FES, the second case being fulminant fat embolism with added mortality.
Thibodeau, Cheryl; McGowan, Amelia
2016-01-01
We report a case of a ruptured left atrial myxoma with multiple synchronous sites of embolization, including the intracranial cerebral (left middle cerebral artery (MCA) and basilar), visceral (renal, superior mesenteric artery (SMA)) and peripheral circulatory beds (aorta and lower extremities). This synchronous embolization resulted in a catastrophic neurologic and systemic event. An intracranial stent retriever was used to restore cerebral circulation in the symptomatic left MCA distribution, which resulted in resolution of the acute neurologic deficits. Endovascular and open surgical interventions were later performed to address the residual cardiac mass and other embolic sites. The patient survived the event with the loss of her right leg below the knee and a transient dialysis requirement. The purpose of this case report is to document the successful utilization of a stent-retriever device in removing an embolized myxoma from the cerebral circulation, to review the unique pathology of this source of embolic stroke and to reiterate the importance of considering embolic and non-thrombotic etiologies of acute ischemic stroke, especially in atypical patient populations and patient presentations. PMID:27306523
Watanabe, Jun; Maruya, Jun; Nishimaki, Keiichi; Ito, Yasushi
2016-01-01
Background: Most dural arteriovenous fistula (DAVF) in superior sagittal sinus (SSS) requires multimodal treatment. Onyx embolization is useful for DAVF; however, scalp artery embolization has cast extrusion risk. Case Description: A 59-year-old male presented with involuntary movements of both legs and progressive dementia. Cerebral angiography demonstrated the DAVF in the SSS fed by bilateral superficial temporal, occipital, and middle meningeal arteries. The posterior SSS was thrombosed, and the main drainers were cortical veins. Combined treatment with transarterial embolization using Onyx and transvenous embolization using coils was performed. Although symptoms were improved, a small DAVF remained. Two months later, Onyx cast extrusion through the scalp was observed, requiring removal and debridement because of infection at the extrusion sites. Surgery for the residual DAVF would be difficult because of scalp condition; therefore, an additional endovascular treatment was conducted, completely occluding DAVF. Conclusion: Onyx embolization is useful for DAVF; however, scalp artery embolization has cast extrusion risk. Therefore, scalp infection should be considered because it may preclude additional surgical procedures. PMID:27313969
Preoperative Embolization of Extra-axial Hypervascular Tumors with Onyx.
Fusco, Matthew R; Salem, Mohamed M; Gross, Bradley A; Reddy, Arra S; Ogilvy, Christopher S; Kasper, Ekkehard M; Thomas, Ajith J
2016-03-01
Preoperative endovascular embolization of intracranial tumors is performed to mitigate anticipated intraoperative blood loss. Although the usage of a wide array of embolic agents, particularly polyvinyl alcohol (PVA), has been described for a variety of tumors, literature detailing the efficacy, safety and complication rates for the usage of Onyx is relatively sparse. We reviewed our single institutional experience with pre-surgical Onyx embolization of extra-axial tumors to evaluate its efficacy and safety and highlight nuances of individualized cases. Five patients underwent pre-surgical Onyx embolization of large or giant extra-axial tumors within 24 hours of surgical resection. Four patients harbored falcine or convexity meningiomas (grade I in 2 patients, grade II in 1 patient and grade III in one patient), and one patient had a grade II hemangiopericytoma. Embolization proceeded uneventfully in all cases and there were no complications. This series augments the expanding literature confirming the safety and efficacy of Onyx in the preoperative embolization of extra-axial tumors, underscoring its advantage of being able to attain extensive devascularization via only one supplying pedicle.
Hydraulic conductivity and embolism in the mangrove tree Laguncularia racemosa.
Ewers, Frank W; Lopez-Portillo, Jórge; Angeles, Guillermo; Fisher, Jack B
2004-09-01
We measured xylem pressure potentials, soil osmotic potentials, hydraulic conductivity and percent loss of conductivity (PLC) due to embolism, and made microscopic observations of perfused dye in the white mangrove tree, Laguncularia racemosa (L.) Gaertn. f., (1) to determine its vulnerability to air embolism compared with published results for the highly salt-tolerant red mangrove tree, Rhizophora mangle L., and (2) to identify possible relationships between air embolism, permanent blockage of vessels and stem diameter. Laguncularia racemosa was more vulnerable to embolism than reported for R. mangle, with 50 PLC at -3.4 MPa. Narrow stems (5-mm diameter) had higher PLC than larger stems (8.4- or 14-mm diameter) of the same plants. Basic fuchsin dye indicated that up to 89% of the vessels, especially in the narrow stems, had permanent blockage that could not be reversed by high pressure perfusion. Air embolism could lead to permanent vessel blockage and eventual stem mortality. Such vulnerability to embolism may restrict the growth of L. racemosa and limit its distribution to less salty areas of mangrove communities.
Chemoembolization of Hepatocellular Carcinoma with Hepasphere 30–60 μm. Safety and Efficacy Study
DOE Office of Scientific and Technical Information (OSTI.GOV)
Malagari, Katerina, E-mail: kmalag@otenet.gr; Pomoni, Maria, E-mail: mpomoni@mail.gr; Moschouris, Hippokratis, E-mail: hipmosch@gmail.com
2013-11-22
Background: This study examined the safety, pharmacokinetics, and efficacy of transarterial chemoembolization of hepatocellular carcinoma (HCC) using a newly developed size of a superabsorbent polymer drug-eluting embolic material.MethodsForty-five patients with documented HCC (Child–Pugh score A/B: 55.5 %/44.5 %) were embolized with HepaSphere microspheres 30–60 μm with escalation of lesion, dose, and frequency of re-embolization. Local response was evaluated with modified response evaluation criteria in solid tumors (mRECIST). Plasma levels of doxorubicin were measured in 24 patients at baseline and at 5, 20, 40, 60, and 120 min, at 6, 24, and 48 h, and at 7 days, respectively, to determine doxorubicin in plasma (Cmax) and areamore » under the curve (AUC). Measurements of three patients who underwent lipiodol-based conventional chemoembolization (c-TACE) were also performed.ResultsTACE with HepaSphere was well tolerated with an acceptable safety profile and no 30-day mortality. Response rates were calculated on intention-to-treat basis with complete response (CR) in 17.8 % reaching 22.2 % for the target lesion. Overall partial response (PR) was seen in 51.1 %, stable disease in 20 %, and progressive disease in 11.1 % of patients. Overall objective response (CR + PR), including patients treated at all dosages of doxorubicin, was seen in 68.9 % of cases. After a median follow-up of 15.6 months, 1-year survival is 100 %. Doxorubicin AUC was significantly lower in patients with HepaSphere 30–60 μm (35,195 ± 27,873 ng × min/ml) than in patients with conventional TACE (103,960 ± 16,652 ng × min/ml; p = 0.009). Cmax was also significantly lower with HepaSphere 30–60 μm (83.9 ± 32.1 ng/ml) compared with c-TACE (761.3 ± 58.8 ng/ml; p = 0.002).ConclusionHepaSphere 30–60 μm is an effective drug-eluting embolic material with a favourable pharmacokinetic profile.« less
Labial necrosis after uterine artery embolization for leiomyomata.
Yeagley, Thomas J; Goldberg, Jay; Klein, Thomas A; Bonn, Joseph
2002-11-01
Uterine artery embolization is increasingly used as an alternative to myomectomy, hysterectomy, and medical treatment for the management of symptomatic leiomyomata. A woman with an 18-week-size fibroid uterus who underwent uterine artery embolization developed a 3-cm, exquisitely tender, hypopigmented, necrotic-appearing area on the right labium minus. Spontaneous resolution occurred over 4 weeks. Labial necrosis is a possible complication of uterine artery embolization and may be successfully managed with conservative therapy.
Cerebral fat embolism after bilateral total knee replacement arthroplasty -A case report-
Chang, Ri-Na; Lee, Heeseung; Baik, Hee-Jung; Chung, Rack Kyung; Kim, Chi Hyo; Hwang, Tae-Hu
2010-01-01
Fat embolism syndrome is a rare and potentially lethal complication most commonly seen in long bone fractures and intramedullary manipulation. The clinical triad of fat embolism syndrome consists of mental confusion, respiratory distress, and petechiae. This study reports a case of cerebral fat embolism syndrome following elective bilateral total knee replacement. After an uneventful anesthesia and initial recovery, the patient developed neurologic symptoms nine hours postoperatively. PMID:21286442
DOE Office of Scientific and Technical Information (OSTI.GOV)
Duncan, I.C., E-mail: docdunc@iafrica.com; Santos, C. Dos
A patient with intractable posterior epistaxis was treated with embolization of the ipsilateral sphenopalatine and facial arteries and contralateral sphenopalatine artery. She continued to bleed despite a seemingly adequate embolization procedure. A second angiogram revealed a significant collateral blood supply to the posterior nasal cavity from the accessory meningeal artery not identified during the first procedure. This was then embolized with no further epistaxis encountered. This case demonstrates yet another collateral arterial pathway that might account for a failed embolization.
Video-assisted open supraclavicular sympathectomy following air embolism.
Shpolyanski, G; Hashmonai, M; Rudin, M; Abaya, N; Kaplan, U; Kopelman, D
2012-01-01
Air embolism is a relatively rare complication of thoracoscopic surgery. Open supraclavicular sympathectomy was indicated to overcome the risk of re-embolization. A novel video-assisted technique was performed. conclusions: The previously prevalent open supraclavicular sympathectomy is a good choice for avoiding air embolism. Laparoscopic instrumentation and technology can be used to improve open procedures, especially when exposure and visibility are limited. Sometimes we should remember to use the experience of our teachers.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Park, Joon Young, E-mail: pjy1331@hanmail.net; Kim, Shin Jung, E-mail: witdd2@hanmail.net; Kim, Hyoung Ook, E-mail: chaos821209@hanmail.net
This study was designed to evaluate the efficacy and safety of CT-guided embolization of internal iliac artery aneurysm (IIAA) after repair of abdominal aortic aneurysm by transretroperitoneal approach using the lidocaine injection technique to iliacus muscle, making window for safe needle path for three patients for whom CT-guided embolization of IIAA was performed by transretroperitoneal approach with intramuscular lidocaine injection technique. Transretroperitoneal access to the IIAA was successful in all three patients. In all three patients, the IIAA was first embolized using microcoils. The aneurysmal sac was then embolized with glue and coils without complication. With a mean follow-up ofmore » 7 months, the volume of the IIAAs remained stable without residual endoleaks. Transretroperitoneal CT-guided embolization of IIAA using intramuscular lidocaine injection technique is effective, safe, and results in good outcome.« less
Nakae, Ryuta; Nagaishi, Masaya; Hyodo, Akio; Suzuki, Kensuke
2017-01-01
N -butyl 2-cyanoacrylate (NBCA) remains the standard embolic agent for spinal dural arteriovenous fistula (SDAVF) treatment. Treatment of SDAVF with ethylene-vinyl alcohol copolymer (Onyx, ev3-Covidien, Irvine CA, USA) is currently not well established. Although several cases have reported the use of Onyx to embolize an intracranial dural arteriovenous fistula using a dual-lumen microballoon catheter, Onyx embolization of an SDAVF using a dual-lumen microballoon catheter has not been reported. We treated a 57-year-old man with an SDAVF using a dual-lumen microballoon catheter and buddy wire technique to perform transarterial Onyx embolization via the left sixth intercostal artery. Onyx embolization using a dual-lumen microballoon catheter was effective. Furthermore, the buddy wire technique was useful for providing rigid support of the microcatheter in a narrow and tortuous intercostal artery.
Nakae, Ryuta; Nagaishi, Masaya; Hyodo, Akio; Suzuki, Kensuke
2017-01-01
Background: N-butyl 2-cyanoacrylate (NBCA) remains the standard embolic agent for spinal dural arteriovenous fistula (SDAVF) treatment. Treatment of SDAVF with ethylene-vinyl alcohol copolymer (Onyx, ev3-Covidien, Irvine CA, USA) is currently not well established. Although several cases have reported the use of Onyx to embolize an intracranial dural arteriovenous fistula using a dual-lumen microballoon catheter, Onyx embolization of an SDAVF using a dual-lumen microballoon catheter has not been reported. Case Description: We treated a 57-year-old man with an SDAVF using a dual-lumen microballoon catheter and buddy wire technique to perform transarterial Onyx embolization via the left sixth intercostal artery. Conclusions: Onyx embolization using a dual-lumen microballoon catheter was effective. Furthermore, the buddy wire technique was useful for providing rigid support of the microcatheter in a narrow and tortuous intercostal artery. PMID:28840070
Transarterial embolization for massive gastrointestinal hemorrhage following abdominal surgery
Zhou, Chun-Gao; Shi, Hai-Bin; Liu, Sheng; Yang, Zheng-Qiang; Zhao, Lin-Bo; Xia, Jin-Guo; Zhou, Wei-Zhong; Li, Lin-Sun
2013-01-01
AIM: To evaluate the clinical results of angiography and embolization for massive gastrointestinal hemorrhage after abdominal surgery. METHODS: This retrospective study included 26 patients with postoperative hemorrhage after abdominal surgery. All patients underwent emergency transarterial angiography, and 21 patients underwent emergency embolization. We retrospectively analyzed the angiographic features and the clinical outcomes of transcatheter arterial embolization. RESULTS: Angiography showed that a discrete bleeding focus was detected in 21 (81%) of 26 patients. Positive angiographic findings included extravasations of contrast medium (n = 9), pseudoaneurysms (n = 9), and fusiform aneurysms (n = 3). Transarterial embolization was technically successful in 21 (95%) of 22 patients. Clinical success was achieved in 18 (82%) of 22 patients. No postembolization complications were observed. Three patients died of rebleeding. CONCLUSION: The positive rate of angiographic findings in 26 patients with postoperative gastrointestinal hemorrhage was 81%. Transcatheter arterial embolization seems to be an effective and safe method in the management of postoperative gastrointestinal hemorrhage. PMID:24187463
Inferior Vena Cava Filter Limb Fracture with Embolization to the Right Ventricle.
Jackson, Bradley S; Sepula, Mykel; Marx, Jared T; Cannon, Chad M
2017-08-01
Inferior vena cava (IVC) filter and filter limb embolization is a known phenomenon, with a prevalence of up to 25% for certain filter types. Most commonly, the site of embolization is to the heart. Point-of-care ultrasound is an easily accessible imaging modality that should be utilized when considering IVC filter complications. A 28-year-old woman with a history of metastatic sarcoma and IVC filter placement for deep venous thrombosis presented to the Emergency Department (ED) for chest pain. Chest radiography was reviewed and originally thought to have no abnormalities. Chest computed tomography angiography was negative for filling defects or foreign bodies. A possible foreign body in the heart was noted by a radiologist's over-read of the original chest radiograph. An echocardiogram done by Cardiology was negative for foreign bodies or other abnormalities. Next, an emergency physician performed a bedside echocardiogram, with focused attention to the right side of the heart. An echogenic foreign body was visualized in the right ventricle. The patient was subsequently taken to the cardiac catheterization laboratory, where fluoroscopic visualization of a limb wire of an IVC filter within the right ventricle was obtained. That foreign body was subsequently removed successfully, along with removal of the broken IVC filter. WHY SHOULD AN EMERGENCY PHYSICIAN BE AWARE OF THIS?: This case report highlights the utility of point-of-care ultrasound in the work-up of a patient with an embolized IVC filter wire. Chest pain patients frequently receive point-of-care echocardiography in the ED, and these ultrasound findings should be recognized and used to guide further treatment and consultation. Copyright © 2017 Elsevier Inc. All rights reserved.
Pernod, Gilles; Wu, Haifeng; de Maistre, Emmanuel; Lazarchick, John; Kassis, Jeannine; Aguilar, Carlos; Vera, Pascual M; Palareti, Gualtiero; D'Angelo, Armando
2017-04-01
: Combined clinical pretest probability (PTP) and D-dimer testing have great diagnostic value for pulmonary embolism exclusion. To harmonize performance levels of D-dimer assays available on the market, the Clinical and Laboratory Standard Institute (CLSI) has published a guideline, endorsed by the US Food and Drug Administration (FDA). Such guideline specifies the ideal D-dimer assay characteristic and target population. This study was conducted following the CLSI guideline to upgrade the assay-intended use and obtain FDA clearance of STA-Liatest D-Di assay for pulmonary embolism exclusion in patient with low/moderate PTP. This was an international, multicenter, prospective nonrandomized, noninterventional clinical outcome management study conducted in a standard of care setting. D-dimer assay was performed in consecutive, ambulatory outpatients suspected of pulmonary embolism, with low/moderate PTP, and without medical conditions or in clinical settings known to alter default D-dimer values regardless of the presence of thrombosis using a threshold of 0.5 μg/ml (fibrinogen equivalent units) for venous thromboembolism exclusion. Results were used to determine test performance. Of 1141 patients who underwent D-dimer testing, 1060 had valid results and completed study as planned. STA-Liatest D-Di assay performance has exceeded the CLSI/FDA guidance requirements, with a sensitivity of 97.6% (95% confidence interval: 91.7-99.7%) and a negative predictive value of 99.7% (95% confidence interval: 99.0-100%). STA-Liatest D-Di assay has an excellent performance when used in combination with a PTP score in relevant patients and has the potential to minimize the economic healthcare burden avoiding unnecessary and expensive imaging tests.
Clarençon, Frédéric; Di Maria, Federico; Cormier, Evelyne; Sourour, Nader-Antoine; Enkaoua, Eric; Sailhan, Frédéric; Iosif, Christina; Le Jean, Lise; Chiras, Jacques
2013-06-01
Presurgical devascularization of hypervascular spinal metastases has been shown to be effective in preventing major blood loss during open surgery. Most often, embolization can be performed using polyvinyl alcohol (PVA) microparticles. However, in some cases, the close relationship between the feeders of the metastases and the feeders of the anterior spinal artery (ASA) poses a risk of spinal cord ischemia when PVA microparticle embolization is performed. The authors present their early experience in the treatment of spinal metastases close to the ASA; in 2 cases they injected Onyx-18, by direct puncture, into hypervascular posterior arch spinal metastases situated close to the ASA. Two women, one 36 and the other 55 years of age, who presented with spinal lesions (at the posterior arch of C-4 and T-6, respectively) from thyroid and a kidney tumors, were sent to the authors' department to undergo presurgical embolization. After having performed a complete spinal digital subtraction angiography study, a regular angiography catheter was positioned at the ostium of the artery that mainly supplied the lesion. Then, with the patient in the left lateral decubitus position, direct puncture with 18-gauge needles of the lesion was performed using roadmap guidance. Onyx-18 was injected through the needles under biplanar fluoroscopy. Satisfactory devascularization of the lesions was obtained; the ASA remained patent in both cases. The metastases were surgically removed in both cases within the 48 hours after the embolization and major blood loss did not occur. Presurgical devascularization of hypervascular spinal metastases close the ASA by direct puncture with Onyx-18 seems to be an effective technique and appears to be safe in terms of the preserving the ASA's patency.
Wajswol, Ethan; Jazmati, Tarek; Contractor, Sohail; Kumar, Abhishek
2018-04-23
To evaluate the safety and effectiveness of n-butyl cyanoacrylate (NBCA) for portal vein embolization (PVE) when used to induce contralateral future liver remnant (FLR) hypertrophy in patients undergoing planned hepatic resection for hepatic malignancy. The PubMed database (including articles indexed by MEDLINE) was searched for articles published from 1970 to 2018 describing patients treated with PVE utilizing NBCA to induce hypertrophy of the FLR prior to contralateral hepatic lobe resection. Demographic data, embolization technique, complications of embolization, resultant FLR hypertrophy, and surgical outcomes were obtained when available. A meta-analysis was performed to determine the cumulative relative hypertrophy rate of the FLR following PVE with NBCA. The literature search yielded 18 relevant articles. Six hundred and seven patients (383 men, 220 women; mean age 60.7 years) with procedures describing PVE utilizing NBCA were reviewed. The most common underlying hepatic malignancies were colorectal metastases (n = 348), followed by cholangiocarcinomas (n = 92), and hepatocellular carcinomas (n = 89). Technical success was reportedly achieved in 603/607 patients, for a success rate of 99.3%. Fixed effects meta-analysis of the relative hypertrophy rate of the FLR among studies resulted in an aggregate rate of 49.4 ± 1.3%. Of the patients who underwent attempted PVE, 461/607 (75.9%) eventually underwent surgical resection. Major complications following PVE occurred in 19 patients (3.13%), while minor complications following PVE occurred in 38 patients (6.26%). PVE utilizing NBCA to induce hypertrophy of the FLR prior to contralateral lobe resection in the setting of hepatic malignancy is safe and effective. Level IIa-Systematic review of cohort studies.
Proposed diagnostic criteria for the case definition of amniotic fluid embolism in research studies
Clark, Steven L.; Romero, Roberto; Dildy, Gary A.; Callaghan, William M.; Smiley, Richard M.; Bracey, Arthur W.; Hankins, Gary D.; D’Alton, Mary E.; Foley, Mike; Pacheco, Luis D.; Vadhera, Rakesh B.; Herlihy, J. Patrick; Berkowitz, Richard L.; Belfort, Michael A.
2016-01-01
Amniotic fluid embolism is a leading cause of maternal mortality in developed countries. Our understanding of risk factors, diagnosis, treatment, and prognosis is hampered by a lack of uniform clinical case definition; neither histologic nor laboratory findings have been identified unique to this condition. Amniotic fluid embolism is often overdiagnosed in critically ill peripartum women, particularly when an element of coagulopathy is involved. Previously proposed case definitions for amniotic fluid embolism are nonspecific, and when viewed through the eyes of individuals with experience in critical care obstetrics, would include women with a number of medical conditions much more common than amniotic fluid embolism. We convened a working group under the auspices of a committee of the Society for Maternal-Fetal Medicine and the Amniotic Fluid Embolism Foundation whose task was to develop uniform diagnostic criteria for the research reporting of amniotic fluid embolism. These criteria rely on the presence of the classic triad of hemodynamic and respiratory compromise accompanied by strictly defined disseminated intravascular coagulopathy. It is anticipated that limiting research reports involving amniotic fluid embolism to women who meet these criteria will enhance the validity of published data and assist in the identification of risk factors, effective treatments, and possibly useful biomarkers for this condition. A registry has been established in conjunction with the Perinatal Research Branch of the Eunice Kennedy Shriver National Institute of Child Health and Human Development to collect both clinical information and laboratory specimens of women with suspected amniotic fluid embolism in the hopes of identifying unique biomarkers of this condition. PMID:27372270
Alderazi, Yazan J; Shastri, Darshan; Wessel, John; Mathew, Melvin; Kass-Hout, Tareq; Aziz, Shahid R; Prestigiacomo, Charles J; Gandhi, Chirag D
2017-05-01
Temporomandibular joint (TMJ) ankylosis causes disability through impaired digestion, mastication, speech, and appearance. Surgical treatment increases range of motion with resultant functional improvement. However, substantial perioperative blood loss can occur (up to 3 L) if the internal maxillary artery (IMAX) is injured as it traverses the ankylotic mass. Achieving hemostasis is difficult because of limited proximal IMAX access and poor visualization. Our aim is to investigate the technical feasibility and preliminary safety of preoperative IMAX embolization in patients undergoing TMJ ankylosis surgery. Case series using chart reviews of 2 patients who underwent preoperative embolization before TMJ ankylosis surgery. Both patients were women (28 and 51 years old) who had severely restricted mouth opening. Embolization was performed using general anesthesia with nasal intubation on the same day of TMJ surgery. Both patients underwent bilateral IMAX embolization using pushable coils (Vortex, Boston Scientific) of distal IMAX followed by n-butyl-cyanoacrylate (Trufill, Cordis) embolization from coil mass up to proximal IMAX. There were no complications from the embolization procedures. Both patients had normal neurologic examination results. TMJ surgery occurred with minimal operative blood loss (≤300 mL for each surgery). Maximum postoperative mouth opening was 35 mm and 34 mm, respectively. One patient had a postoperative TMJ wound infection that was managed with antibiotics. Preoperative IMAX embolization before TMJ ankylosis surgery is technically feasible with encouraging preliminary safety. There were no complications from the embolization procedures and surgeries occurred with low volumes of blood loss. Copyright © 2017 Elsevier Inc. All rights reserved.
Flow control techniques for Onyx embolization of intracranial dural arteriovenous fistulae.
Shi, Zhong-Song; Loh, Yince; Gonzalez, Nestor; Tateshima, Satoshi; Feng, Lei; Jahan, Reza; Duckwiler, Gary; Viñuela, Fernando
2013-07-01
Experience of flow control techniques during endovascular treatment of intracranial dural arteriovenous fistulas (DAVFs) using the Onyx liquid embolic system is reported, with an emphasis on high flow shunts. Data were evaluated in patients with DAVFs treated endovascularly with Onyx. Adjunctive techniques with coils, acrylics and balloon assistance were utilized to reduce the rate of flow with transarterial and transvenous approaches. The following types of adjunctive techniques were used in 58 patients who underwent a total of 84 embolization sessions with Onyx: transvenous coiling with transvenous or transarterial Onyx embolization in 36 patients, transarterial coiling with transarterial Onyx embolization in eight patients, arterial or venous balloon assisted technique with transarterial or transvenous Onyx embolization in 11 patients, transarterial high concentration acrylics with transarterial Onyx embolization in one patient and staged transarterial or transvenous coiling and Onyx embolization in two patients. Complete obliteration of the fistulae was achieved in 41 patients (70.7%) and 27 patients (65.9%) with high flow fistulae after endovascular treatment alone. Periprocedural complications were encountered in 16 patients, and 13 complications were associated with the adjunctive techniques. There were four neurologic and two non-neurologic clinical sequelae. Distal Onyx migration occurred in four, microcatheter retention in three and cranial neuropathy in three patients. There was one instance each of cerebellar hemorrhage, thromboembolism, coil stretching and retention, and dissection. 56 survivors experienced complete resolution or significant improvement of their symptoms on follow-up. Flow control techniques are safe and effective adjunctive methods in primary endovascular Onyx embolization of high flow DAVFs.
Proposed diagnostic criteria for the case definition of amniotic fluid embolism in research studies.
Clark, Steven L; Romero, Roberto; Dildy, Gary A; Callaghan, William M; Smiley, Richard M; Bracey, Arthur W; Hankins, Gary D; D'Alton, Mary E; Foley, Mike; Pacheco, Luis D; Vadhera, Rakesh B; Herlihy, J Patrick; Berkowitz, Richard L; Belfort, Michael A
2016-10-01
Amniotic fluid embolism is a leading cause of maternal mortality in developed countries. Our understanding of risk factors, diagnosis, treatment, and prognosis is hampered by a lack of uniform clinical case definition; neither histologic nor laboratory findings have been identified unique to this condition. Amniotic fluid embolism is often overdiagnosed in critically ill peripartum women, particularly when an element of coagulopathy is involved. Previously proposed case definitions for amniotic fluid embolism are nonspecific, and when viewed through the eyes of individuals with experience in critical care obstetrics, would include women with a number of medical conditions much more common than amniotic fluid embolism. We convened a working group under the auspices of a committee of the Society for Maternal-Fetal Medicine and the Amniotic Fluid Embolism Foundation whose task was to develop uniform diagnostic criteria for the research reporting of amniotic fluid embolism. These criteria rely on the presence of the classic triad of hemodynamic and respiratory compromise accompanied by strictly defined disseminated intravascular coagulopathy. It is anticipated that limiting research reports involving amniotic fluid embolism to women who meet these criteria will enhance the validity of published data and assist in the identification of risk factors, effective treatments, and possibly useful biomarkers for this condition. A registry has been established in conjunction with the Perinatal Research Branch of the Eunice Kennedy Shriver National Institute of Child Health and Human Development to collect both clinical information and laboratory specimens of women with suspected amniotic fluid embolism in the hopes of identifying unique biomarkers of this condition. Copyright © 2016 Elsevier Inc. All rights reserved.
Srinivasa, Ravi N; Chick, Jeffrey Forris Beecham; Hage, Anthony; Ramamurthi, Aishu; Wolf, J Stuart; Gemmete, Joseph J; Dauw, Casey A
2017-10-01
Removal of embolization coils eroded into the renal collecting system poses a risk of hemorrhage, which may need to be addressed with arteriography and embolization at the time of treatment. The purpose of this report is to describe a novel approach, by which prone percutaneous nephroscopic coil retrieval is coupled with simultaneous prone transradial renal arterial access to mitigate this potential complication. A retrospective chart review of the electronic medical record systems was performed from January 2008 to May 2017 to identify patients who had undergone percutaneous removal of embolization coils eroded into the renal collecting system. Patients who had migration of embolization coils into the renal collecting system who were symptomatic with pain, hydronephrosis, or infection were considered for inclusion. Patients who had coil migration, but were asymptomatic were not offered removal. Patient demographics and case characteristics were examined as were operative outcomes. A total of three patients fulfilled the study criteria. Migrated embolization coils were able to be effectively removed in all patients. Of the patients, two underwent simultaneous prone transradial renal arteriography with placement of an occlusion balloon catheter into the segmental artery of interest. In one patient, significant arterial bleeding was encountered after coil removal, which was effectively addressed with simultaneous arteriography and glue embolization. Erosion of embolization coils into the renal collecting system, while rare, may be a significant long-term complication of coil embolization. Combining nephroscopy with prone transradial arteriography in preparation for procedure-associated hemorrhage may make removal of migrated coils safer.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pech, Maciej, E-mail: maciej.pech@med.ovgu.de; Kraetsch, Annett; Wieners, Gero
2009-05-15
The Amplatzer Vascular Plug II (AVP II) is a novel device for transcatheter vessel occlusion, for which only limited comparative data exist. Embolotherapy of the gastroduodenal artery (GDA) is essential before internal radiotherapy (SIRT) in order to prevent radiation-induced peptic ulcerations due to migration of yttrium-90 microspheres. The purpose of this study was to compare the vascular anatomical limitations, procedure time, effectiveness, and safety of embolization of the GDA with coils versus the AVP II. Fifty patients stratified for SIRT were prospectively randomized for embolization of the GDA with either coils or the AVP II. The angle between the aortamore » and the celiac trunk, diameter of the GDA, fluoroscopy time and total time for embolization, number of embolization devices, complications, and durability of vessel occlusion at follow-up angiography for SIRT were recorded. A t-test was used for statistical analysis. Embolizations with either coils or the AVP II were technically feasible in all but two patients scheduled for embolization of the GDA with the AVP II. In both cases the plug could not be positioned due to the small celiac trunk outlet angles of 17{sup o} and 21{sup o}. The mean diameter of the GDA was 3.7 mm (range, 2.2-4.8 mm) for both groups. The procedures differed significantly in fluoroscopy time (7.8 min for coils vs. 2.6 min for the AVP II; P < 0.001) and embolization time (23.1 min for coils vs. 8.8 min for the AVP II; P < 0.001). A mean of 6.0 {+-} 3.2 coils were used for GDA embolization, while no more than one AVP II was needed for successful vessel occlusion (P < 0.001). One coil migration occurred during coil embolization, whereas no procedural complication was encountered with the use of the AVP II. Vessel reperfusion was noted in only one patient, in whom coil embolization was performed. In conclusion, embolization of the GDA with the AVP II is safe, easy, rapid, and highly effective; only an extremely sharp-angled celiac trunk outlet represented an anatomical limitation for device deployment.« less
Percutaneous Embolization of Transhepatic Tracks for Biliary Intervention
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lyon, Stuart M.; Terhaar, Olaf; Given, Mark F.
2006-12-15
Significant pain can occur after removing transhepatic catheters from biliary access tracks, after percutaneous biliary drainage (PBD) or stenting. We undertook a randomized prospective study to ascertain whether track embolization decreases the amount of pain or analgesic requirement after PBD. Fifty consecutive patients (M:F, 22:28; age range:29-85 years; mean age: 66.3 years) undergoing PBD were randomized to receive track embolization or no track embolization after removal of biliary drainage catheters. A combination of Lipoidol and n-butyl cyanoacrylate were used to embolize transhepatic tracks using an 8F dilator. The patients who did not have track embolization performed had biliary drainage cathetersmore » removed over a guide wire. A visual analog scoring (VAS) system was used to grade pain associated with catheter removal, 24 h afterward. A required analgesic score (RAS) was devised to tabulate the analgesia required. No analgesia had a score of 0, oral or rectal nonopiate analgesics had a score of 1, oral opiates had a score of 2, and parenteral opiates had a score of 3. The average VAS and RAS for both groups were calculated and compared.Seven patients were excluded for various reasons, leaving 43 patients in the study group. Twenty-one patients comprised the embolization group and 22 patients comprised the nonembolization group. The mean biliary catheter dwell time was not significantly different (p > 0.05) between the embolization group and nonembolization (mean: 5.4 days vs 6.9 days, respectively). In the nonembolization group, the mean VAS was 3.4. Eight patients required parenteral opiates, three patients required oral opiates, and five patients required oral or rectal analgesics, yielding a mean RAS of 1.6. In the embolization group, the mean VAS was 0.9. No patient required parenteral opiates, six patients required oral opiates, and two patients had oral analgesia. The average RAS was 0.6. Both the VAS and the RAS were significantly lower in the embolization group compared with the nonembolization group (p < 0.0023 and p < 0.002, respectively). No complications were seen related to track embolization. Percutaneous track embolization after removal of biliary drainage catheters decreases patient's perception of pain and decreases the amount of required analgesia. In particular, the amount of opiate analgesia required is considerably less.« less
Cardiovascular ultrasonography detection of embolic sources in trauma.
Saranteas, Theodosios; Mavrogenis, Andreas F; Poularas, John; Kostroglou, Andreas; Mandila, Christina; Panou, Fotios
2018-06-01
Venous thromboembolism (deep vein thrombosis and pulmonary embolism) and bone cement implantation syndrome are major sources of embolic events in trauma patients. In these patients, embolic events due to venous thromboembolism and bone cement implantation syndrome have been detected with cardiac and vascular ultrasonography in the emergency setting, during the perioperative period, and in the intensive care unit. This article discusses the ultrasonography modalities and imaging findings of embolic events related to venous thromboembolism and bone cement implantation syndrome. The aim is to present a short review with exceptional illustrations that can enable physicians to identify sources of emboli in trauma patients with cardiovascular ultrasonography. Copyright © 2018 Elsevier Inc. All rights reserved.
Kierkegaard, A
1998-08-19
Echocardiographic diagnosis of acute pulmonary embolism as illustrated by three case reports is discussed in the article. Acute pulmonary embolism was diagnosed by demonstration of right heart strain in one case, of long vermiform thrombi floating in the right atrium in another, and in the third case by demonstration of a long thrombus lodged in the foramen ovale, astride the atrial septum, and with its ends floating in either atrium. Thus, as echocardiography enables pulmonary embolism to be diagnosed by demonstration either of right heart strain or of intracardial thrombi, it is a useful diagnostic tool in cases of haemodynamic compromise, though it does not detect minor pulmonary embolism.
Chao, Christine P; Paz-Fumagalli, Ricardo; Walser, Eric M; McKinney, J Mark; Stockland, Andrew H; Falkensammer, Jürgen; Hakaim, Albert G; Oldenburg, W Andrew
2006-11-01
Bowel ischemia can complicate treatment of type II endoleak with liquid or semiliquid agents such as n-butyl cyanoacrylate (NBCA) if nontarget embolization of the inferior mesenteric artery (IMA) occurs. The current report describes four cases of type II endoleak in which the IMA was the main outflow vessel and was prophylactically occluded with embolization coils before NBCA injection into the endoleak nidus. The purpose was to prevent unintentional embolization of the NBCA into IMA branches. If feasible, protective IMA coil occlusion should be considered in type II endoleaks with IMA outflow in cases of NBCA embolization.
Fat embolism due to bilateral femoral fracture: a case report
Porpodis, Konstantinos; Karanikas, Michael; Zarogoulidis, Paul; Konoglou, Maria; Domvri, Kalliopi; Mitrakas, Alexandros; Boglou, Panagiotis; Bakali, Stamatia; Iordanidis, Alkis; Zervas, Vasilis; Courcoutsakis, Nikolaos; Katsikogiannis, Nikolaos; Zarogoulidis, Konstantinos
2012-01-01
Fat embolism syndrome is usually associated with surgery for large bone fractures. Symptoms usually occur within 36 hours of hospitalization after traumatic injury. We present a case with fat embolism syndrome due to femur fracture. Prompt supportive treatment of the patient’s respiratory system and additional pharmaceutical treatment provided the positive clinical outcome. There is no specific therapy for fat embolism syndrome; prevention, early diagnosis, and adequate symptomatic treatment are very important. Most of the studies in the last 20 years have shown that the incidence of fat embolism syndrome is reduced by early stabilization of the fractures and the risk is even further decreased with surgical correction rather than conservative management. PMID:22287848
Fat embolism due to bilateral femoral fracture: a case report.
Porpodis, Konstantinos; Karanikas, Michael; Zarogoulidis, Paul; Konoglou, Maria; Domvri, Kalliopi; Mitrakas, Alexandros; Boglou, Panagiotis; Bakali, Stamatia; Iordanidis, Alkis; Zervas, Vasilis; Courcoutsakis, Nikolaos; Katsikogiannis, Nikolaos; Zarogoulidis, Konstantinos
2012-01-01
Fat embolism syndrome is usually associated with surgery for large bone fractures. Symptoms usually occur within 36 hours of hospitalization after traumatic injury. We present a case with fat embolism syndrome due to femur fracture. Prompt supportive treatment of the patient's respiratory system and additional pharmaceutical treatment provided the positive clinical outcome. There is no specific therapy for fat embolism syndrome; prevention, early diagnosis, and adequate symptomatic treatment are very important. Most of the studies in the last 20 years have shown that the incidence of fat embolism syndrome is reduced by early stabilization of the fractures and the risk is even further decreased with surgical correction rather than conservative management.
Cerebral Embolic Activity in a Patient during Acute Crisis of Takayasu's Arteritis
Nogueira, Ricardo de Carvalho; Bor-Seng-Shu, Edson; Marchiori, Paulo Eurípedes; Teixeira, Manoel Jacobsen
2012-01-01
Takayasu's arteritis is a disease that affects large vessels and may cause neurological symptoms either by stenoses/occlusions or embolisms from vessels with an inflammatory process. Transcranial Doppler (TCD) ultrasound can provide useful information for diagnosis and monitoring during the active phase of the disease. Cerebral embolic signals can be detected by TCD and have been considered a risk factor for vascular events. We report a patient in whom TCD ultrasound was used to monitor cerebral embolic signals during the active phase of the disease. This case report suggests that embolic activity in Takayasu's arteritis may represent disease activity, and its monitoring may be useful for evaluating the response to therapy. PMID:22379479
Effects of He-O2 Breathing during Experimental Decompression Sickness Following Air Dives
1987-03-01
sickness (DCS1 and venous air embolism were studied . Fifteen anestht zed dogs were mechanically ventilated and subjected to repeated air dives until...animals with He-0 2 during venous air embolism worsens pulmonary hypertension and hypoxemia (9). To test this hypothesis, we studied the effects of He...additional animals (air embolism group), gas switching was studied during venous air embolism at I ATA. These animals were anesthetized and instnmented as
Choat, Brendan; Brodersen, Craig R; McElrone, Andrew J
2015-02-01
The formation of emboli in xylem conduits can dramatically reduce hydraulic capacity and represents one of the principal mechanisms of drought-induced mortality in woody plants. However, our understanding of embolism formation and repair is constrained by a lack of tools to directly and nondestructively measure these processes at high spatial resolution. Using synchrotron-based microcomputed tomography (microCT), we examined embolism in the xylem of coast redwood (Sequoia sempervirens) saplings that were subjected to cycles of drought and rewatering. Embolism formation was observed occurring by three different mechanisms: as tracheids embolizing in wide tangential bands; as isolated tracheids in seemingly random events; and as functional groups connected to photosynthetic organs. Upon rewatering, stem water potential recovered to predrought stress levels within 24 h; however, no evidence of embolism repair was observed even after a further 2 wk under well-watered conditions. The results indicate that intertracheid air seeding is the primary mechanism by which embolism spreads in the xylem of S. sempervirens, but also show that a small number of tracheids initially become gas-filled via another mechanism. The inability of S. sempervirens saplings to reverse drought-induced embolism is likely to have important ecological impacts on this species. © 2014 The Authors. New Phytologist © 2014 New Phytologist Trust.
Ischemic stroke due to embolic heart diseases and associated factors in Benin hospital setting.
Gnonlonfoun, Dieudonné; Adjien, Constant; Gnimavo, Ronald; Goudjinou, Gérard; Hotcho, Corine; Nyangui Mapaga, Jennifer; Sowanou, Arlos; Gnigone, Pupchen; Domingo, Rodrigue; Houinato, Dismand
2018-04-15
Poor access to cardiovascular checkups is a major cause of ignorance of embolic heart diseases as the etiology for ischemic stroke. Study ischemic strokes due to embolic heart diseases and their associated factors. It was a cross-sectional, prospective, descriptive and analytical study conducted from November 1, 2014 to August 31, 2015 on 104 patients with ischemic stroke confirmed through brain imaging. Embolic heart diseases included arrhythmia due to atrial fibrillation (AF), atrial flutter, myocardial infarction (MI), heart valve diseases and atrial septal aneurysm (ASA). The dependent variable was embolic heart disease while independent variables encompassed socio-demographic factors, patients' history, and lifestyle. Data analysis was carried out through SAS 9.3. The rate of embolic heart diseases (EHD) as etiology for ischemic stroke was 26% (28/104). AF accounted for 69% of embolic heart diseases and 22.8% of etiologies for ischemic stroke. Ischemic strokes prevalence was 3.5%, 2.5% and 1.2% respectively for heart valve diseases, MI and ASA. The associated factor was age (p=0.000). The diagnosis of a potential cardiac source of embolism is essential because of therapeutic and prognostic implications. Wherefore, there is need for cardiovascular examination particularly Holter ECG and cardiac ultrasound examination which are not always accessible to our populations. Copyright © 2018 Elsevier B.V. All rights reserved.
The influence of weather and environment on pulmonary embolism: pollutants and fossil fuels.
Clauss, Ralf; Mayes, Julian; Hilton, Paul; Lawrenson, Ross
2005-01-01
Previous publications have highlighted seasonal variations in the incidence of thrombosis and pulmonary embolism, and that weather patterns can influence these. While medical risk factors for pulmonary thrombo-embolism such as age, obesity, hypercoagulable states, cancer, previous thrombo-embolism, immobility, limb paralysis, surgery, major illness, trauma, hypotension, tachypnoea and right ventricular hypokinesis are not directly implicated regarding environmental factors such as weather, they could be influenced indirectly by these. This would be especially relevant in polluted areas that are associated with a higher pulmonary embolism risk. Routine nuclear medicine lung ventilation/perfusion studies (V/Q scans) of 2071 adult patients referred to the nuclear medicine department of the Royal Surrey County Hospital in Guildford, UK, between January 1998 and October 2002 were reviewed and 316 of these patients were classified as positive for pulmonary embolism with high probability scan on PIOPED criteria. The occurrence of positive scans was compared to environmental factors such as temperature, humidity, vapour pressure, air pressure and rainfall. Multiple linear regression was used to establish the significance of these relations. The incidence of pulmonary embolism was positively related to vapour pressure and rainfall. The most significant relation was to vapour pressure (p=0.010) while rainfall was less significant (p=0.017). There was no significant relation between pulmonary embolism and air pressure, humidity or temperature. It is postulated that rainfall and water vapour may be contributary factors in thrombosis and pulmonary embolism by way of pollutants that are carried as condensation nuclei in micro-droplets of water. In particular, fossil fuel pollutants are implicated as these condensation nuclei. Pollutants may be inhaled by populations exposed to windborne vapour droplets in cities or airports. Polluted vapour droplets may be absorbed by the lung to hasten coagulation cascades in the blood. This may lead to thrombosis and increased pulmonary embolism under high vapour pressure conditions. With combined factors such as pre-existing ill health or immobility on long flights, the risk of thrombosis and consequent embolism might increase substantially.
Goto, Shinya; Merrill, Peter; Wallentin, Lars; Wojdyla, Daniel M; Hanna, Michael; Avezum, Alvaro; Easton, J Donald; Harjola, Veli-Pekka; Huber, Kurt; Lewis, Basil S; Parkhomenko, Alexander; Zhu, Jun; Granger, Christopher B; Lopes, Renato D; Alexander, John H
2018-04-01
We investigated baseline characteristics, antithrombotic use, and clinical outcomes of patients with atrial fibrillation (AF) and a thrombo-embolic event in the Apixaban for Reduction in Stroke and Other Thromboembolic Events in Atrial Fibrillation (ARISTOTLE) study to better inform the care of these high-risk patients. Thrombo-embolic events were defined as stroke (ischaemic or unknown cause) or systemic embolism (SE). Clinical outcomes were estimated using the Kaplan-Meier method. All-cause mortality and International Society on Thrombosis and Haemostasis (ISTH) major bleeding after events were analysed using a Cox proportional hazards model with time-dependent covariates. Of 18 201 patients in ARISTOTLE, 365 experienced a thrombo-embolic event [337 strokes (ischaemic or unknown cause), 28 SE]; 46 (12.6%) of which were fatal. In the 30 days before and after a thrombo-embolic event, 11% and 37% of patients, respectively, were not taking an oral anticoagulant. During follow-up (median 1.8 years), 22 patients (7.1%/year) had a recurrent stroke, 97 (30.1%/year) died, and 10 (6.7%/year) had major bleeding. Compared with patients without a thrombo-embolic event, the short- and long-term adjusted hazards of death in patients with a thrombo-embolic event were high [≤30 days: hazard ratio (HR) 54.3%, 95% confidence interval (95% CI) 41.4-71.3; >30 days: HR 3.5, 95% CI 2.5-4.8; both P < 0.001]. The adjusted hazards of major bleeding were also high short-term (HR 10.37, 95% CI 3.87-27.78; P < 0.001) but not long-term (HR 1.7, 95% CI: 0.77-3.88; P = 0.18). Thrombo-embolic events were rare but associated with high short- and long-term morbidity and mortality. Substantial numbers of patients are not receiving oral anticoagulattherapy before and, despite this risk, after a first thrombo-embolic event. ClinicalTrials.gov (NCT00412984).
Kobayashi, Daisuke; Gowda, Srinath T; Forbes, Thomas J
2014-08-01
A 9-year-old male, with history of pulmonary atresia and ventricular septal defect, status post complete repair with a 16 mm pulmonary homograft in the right ventricular outflow tract (RVOT) underwent 3110 Palmaz stent placement for conduit stenosis. Following deployment the stent embolized proximally into the right ventricle (RV). We undertook the choice of repositioning the embolized stent into the conduit with a transcatheter approach. Using a second venous access, the embolized stent was carefully maneuvered into the proximal part of conduit with an inflated Tyshak balloon catheter. A second Palmaz 4010 stent was deployed in the distal conduit telescoping through the embolized stent. The Tyshak balloon catheter was kept inflated in the RV to stabilize the embolized stent in the proximal conduit until it was successfully latched up against the conduit with the deployment of the overlapping second stent. One year later, he underwent Melody valve implantation in the pre-stented conduit relieving conduit insufficiency. This novel balloon assisted two-stents telescoping technique is a feasible transcatheter option to secure an embolized stent from the RV to the RVOT. © 2014 Wiley Periodicals, Inc.
Bakan, Mefkur; Topuz, Ufuk; Esen, Asim; Basaranoglu, Gokcen; Ozturk, Erdogan
2013-01-01
The anesthesiologist must be aware of the causes, diagnosis and treatment of venous air embolism and adopt the practice patterns to prevent its occurrence. Although venous air embolism is a known complication of cesarean section, we describe an unusual inattention that causes iatrogenic near fatal venous air embolism during a cesarean section under spinal anesthesia. One of the reasons for using self-collapsible intravenous (IV) infusion bags instead of conventional glass or plastic bottles is to take precaution against air embolism. We also demonstrated the risk of air embolism for two kinds of plastic collapsible intravenous fluid bags: polyvinyl chloride (PVC) and polypropylene-based. Fluid bags without self-sealing outlets pose a risk for air embolism if the closed system is broken down, while the flexibility of the bag limits the amount of air entry. PVC-based bags, which have more flexibility, have significantly less risk of air entry when IV administration set is disconnected from the outlet. Using a pressure bag for rapid infusion can be dangerous without checking and emptying all air from the IV bag. 2013 Sociedade Brasileira de Anestesiologia. Published by Elsevier Editora Ltda. All rights reserved.
Bakan, Mefkur; Topuz, Ufuk; Esen, Asim; Basaranoglu, Gokcen; Ozturk, Erdogan
2013-01-01
The anesthesiologist must be aware of the causes, diagnosis and treatment of venous air embolism and adopt the practice patterns to prevent its occurrence. Although venous air embolism is a known complication of cesarean section, we describe an unusual inattention that causes iatrogenic near fatal venous air embolism during a cesarean section under spinal anesthesia. One of the reasons for using self-collapsible intravenous (IV) infusion bags instead of conventional glass or plastic bottles is to take precaution against air embolism. We also demonstrated the risk of air embolism for two kinds of plastic collapsible intravenous fluid bags: polyvinyl chloride (PVC) and polypropylene-based. Fluid bags without self-sealing outlets pose a risk for air embolism if the closed system is broken down, while the flexibility of the bag limits the amount of air entry. PVC-based bags, which have more flexibility, have significantly less risk of air entry when IV administration set is disconnected from the outlet. Using a pressure bag for rapid infusion can be dangerous without checking and emptying all air from the IV bag. Copyright © 2013 Sociedade Brasileira de Anestesiologia. Published by Elsevier Editora Ltda. All rights reserved.
Crisis management during anaesthesia: embolism
Williamson, J; Helps, S; Westhorpe, R; Mackay, P
2005-01-01
Background: Embolism with gas, thrombus, fat, amniotic fluid, or particulate matter may occur suddenly and unexpectedly during anaesthesia, posing a diagnostic and management problem for the anaesthetist. Objectives: To examine the role of a previously described core algorithm "COVER ABCD–A SWIFT CHECK" supplemented by a specific sub-algorithm for embolism, in the management of embolism occurring in association with anaesthesia. Methods: The potential performance of this structured approach for each of the relevant incidents among the first 4000 reported to the Australian Incident Monitoring Study (AIMS) was compared with the actual management as reported by the anaesthetists involved. Results: Among the first 4000 incidents reported to AIMS, 38 reports of embolism were found. A sudden fall in end-tidal carbon dioxide and oxygen saturation were the cardinal signs of embolism, each occurring in about two thirds of cases, with hypotension and electrocardiographic changes each occurring in about one third of cases. Conclusion: The potential value of an explicit structured approach to the diagnosis and management of embolism was assessed in the light of AIMS reports. It was considered that, correctly applied, it potentially would have led to earlier recognition of the problem and/or better management in over 40% of cases. PMID:15933290
Pulmonary Embolization of Fat and Bone Marrow in Cynomolgus Macaques (Macaca fascicularis)
Fong, Derek L.; Murnane, Robert D.; Hotchkiss, Charlotte E.; Green, Damian J.; Hukkanen, Renee R.
2011-01-01
Fat embolization (FE), the introduction of bone marrow elements into circulation, is a known complication of bone fractures. Although FE has been described in other animal models, this study represents the first reported cases of FE and bone marrow embolism in nonhuman primates. Histopathologic findings from cynomolgus macaques (Macaca fascicularis) indicated that in all 5 cases, fat and bone marrow embolization occurred subsequent to multiple bone marrow biopsies. In the most severe case, extensive embolization was associated pulmonary damage consistent with acute respiratory distress syndrome. Fat embolism syndrome (FES) is an infrequent clinical outcome of FE and is triggered by systemic biochemical and mechanical responses to fat in circulation. Although clinical criteria diagnostic of FES were not investigated at the time of death, this severe case may represent the fulminant form of FES, which occurs within 12 h after trauma. Bone marrow biopsy as an etiology of FES has been reported only once in humans. In addition, the association of embolization with bone marrow biopsies suggests that nonhuman primates may be a useful animal model of FE. FE and FES represent important research confounders and FES should be considered as a differential diagnosis for clinical complications subsequent to skeletal trauma. PMID:21819686
Pulmonary embolization of fat and bone marrow in cynomolgus Macaques (Macaca fascicularis).
Fong, Derek L; Murnane, Robert D; Hotchkiss, Charlotte E; Green, Damian J; Hukkanen, Renee R
2011-02-01
Fat embolization (FE), the introduction of bone marrow elements into circulation, is a known complication of bone fractures. Although FE has been described in other animal models, this study represents the first reported cases of FE and bone marrow embolism in nonhuman primates. Histopathologic findings from cynomolgus macaques (Macaca fascicularis) indicated that in all 5 cases, fat and bone marrow embolization occurred subsequent to multiple bone marrow biopsies. In the most severe case, extensive embolization was associated pulmonary damage consistent with acute respiratory distress syndrome. Fat embolism syndrome (FES) is an infrequent clinical outcome of FE and is triggered by systemic biochemical and mechanical responses to fat in circulation. Although clinical criteria diagnostic of FES were not investigated at the time of death, this severe case may represent the fulminant form of FES, which occurs within 12 h after trauma. Bone marrow biopsy as an etiology of FES has been reported only once in humans. In addition, the association of embolization with bone marrow biopsies suggests that nonhuman primates may be a useful animal model of FE. FE and FES represent important research confounders and FES should be considered as a differential diagnosis for clinical complications subsequent to skeletal trauma.
Richards, Robin R.
1997-01-01
Fat embolism syndrome, an important contributor to the development of acute respiratory distress syndrome, has been associated with both traumatic and nontraumatic disorders. Fat embolization after long bone trauma is probably common as a subclinical event. Fat emboli can deform and pass through the lungs, resulting in systemic embolization, most commonly to the brain and kidneys. The diagnosis of fat embolism syndrome is based on the patient’s history, supported by clinical signs of pulmonary, cerebral and cutaneous dysfunction and confirmed by the demonstration of arterial hypoxemia in the absence of other disorders. Treatment of fat embolism syndrome consists of general supportive measures, including splinting, maintenance of fluid and electrolyte balance and the administration of oxygen. Endotracheal intubation and mechanical ventilatory assistance can be indicated. The role of corticosteroids remains controversial. Early stabilization of long bone fractures has been shown to decrease the incidence of pulmonary complications. Clinical and experimental studies suggest that the exact method of fracture fixation plays a minor role in the development of pulmonary dysfunction. As more is learned about the specifics of the various triggers for the development of fat embolism syndrome, it is hoped that the prospect of more specific therapy for the prevention and treatment of this disorder will become a reality. PMID:9336522
[Pulmonary and systemic fat embolism as a cause of death in forensic autopsy practice].
Akçay Turan, Arzu; Celik, Safa; Karayel, Ferah; Pakiş, Işil; Arican, Nadir
2006-04-01
The aim of this study was to evaluate the possible correlations between the grade of fat embolism and age, gender, severity of trauma and post-traumatic survival time. Thirty-one cases with pulmonary and/or systemic fat embolism, auotopsied at the Morgue Department of Council of Forensic Medicine were evaluated retrospectively. Twenty-eight cases (90%) died due to trauma and its complications. Nineteen cases (61%) were injured in motor vehicle-related accidents. Post-traumatic survival time varied between 0-384 hours (61.6+/-86.2 hours). Abbreviated injury scale (AIS) was 8.1+/-3.9 and injury severity score (ISS) was 26.5+/-19.7 SD. Twenty-four (77%) cases were determined as isolated pulmonary fat embolism and 7 (23%) cases as systemic fat embolism on histopathological examination. Possible correlations between the grade of fat embolism and age, gender, severity of trauma and post-traumatic survival time were evaluated statistically with using Chi-square and Spearman's correlation tests. There were no correlations between the grade of fat embolism and age, gender, the severity of trauma. Post-traumatic survival time and the severity of trauma had a very weak negative correlation without any statistical significance.
Interventional embolization of congenital intrahepatic shunts in children.
Wu, Lin; Zhao, Lu; Lu, Ying; He, Lan; Hu, Xihong
2016-04-01
Congenital intrahepatic shunts in children are rare and precise treatment strategies have not been established. The purpose of this study was to present our experience with transcatheter embolization in a descriptive case series of congenital intrahepatic shunts in children. We retrospectively studied 10 children with symptomatic congenital intrahepatic shunts who were treated with embolization at our institute between January 2008 and December 2014. Seven children had arteriovenous shunts in association with hepatic hemangiomas, two had arterioportal shunts and one had portosystemic shunts. The major presentations were congestive heart failure and severe anemia in the groups with arteriovenous and arterioportal shunts, respectively. Following embolization, two children died in the arteriovenous group, one from progressive liver dysfunction and the other from abdominal compartment syndrome. One child in the arterioportal group required liver transplantation after initial embolization. With mean post-procedure follow-up of 15 months (range 4-54 months), all the remaining children were well, with resolution of the symptoms. Interventional embolization provides an alternative to surgical ligation or hepatic resection in children with clinically significant intrahepatic shunts. For lesions with complex morphology, embolization may be inadequate and liver transplantation might be the only therapeutic option.
Jiang, Jun; Jiao, Yuanyong; Zhang, Xiwei
2017-10-01
Objectives To perform a meta-analysis of randomized controlled trials assessing the effectiveness of inferior vena cava filters in patients with deep vein thrombosis for preventing pulmonary embolism. Method Relevant randomized controlled trials of inferior vena cava filters for the prevention of pulmonary embolism were identified by searching electronic databases updated in February 2016. Relative risks of recurrent pulmonary embolism, recurrent deep vein thrombosis, and mortality at three months were analyzed. Results Three published randomized controlled trials were included involving a total of 863 deep vein thrombosis patients. No significant differences were detected with inferior vena cava filters placement with regard to the incidence of recurrent pulmonary embolism or fatal pulmonary embolism. There were also no significant differences in the incidence of recurrent deep vein thrombosis or mortality with inferior vena cava filters placement at three months. Conclusions Inferior vena cava filter in addition to anticoagulation was not associated with a reduction in the incidence of recurrent pulmonary embolism as compared with anticoagulation alone in patients with deep vein thrombosis in the short term.
Secchi, Francesca; Gilbert, Matthew E.; Zwieniecki, Maciej A.
2011-01-01
The mechanism of embolism repair in transpiring plants is still not understood, despite significant scientific effort. The refilling process is crucial to maintaining stem transport capacity and ensuring survival for plants experiencing dynamic changes in water stress. Refilling air-filled xylem vessels requires an energy and water source that can only be provided by adjacent living parenchyma cells. Here, we report an analysis of the transcriptome response of xylem parenchyma cells after embolism formation in Populus trichocarpa trees. Genes encoding aquaporins, ion transporters, and carbohydrate metabolic pathways were up-regulated, and there was a significant reduction in the expression of genes responding to oxidative stress. Thus, a novel view of the plant response to embolism emerges that suggests a role for oxygen in embolized vessels as a signal triggering xylem refilling and for the activity of cation transport as having a significant role in the generation of the energy gradient necessary to heal embolized vessels. These findings redefine current hypotheses surrounding the refilling phenomenon and provide insight into the complexity of the biological response to the seemingly simple physical event of xylem embolism formation. PMID:21951466
Mayr, Stefan; Gruber, Andreas; Bauer, Helmut
2003-07-01
Freezing and thawing lead to xylem embolism when gas bubbles caused by ice formation expand during the thaw process. However, previous experimental studies indicated that conifers are resistant to freezing-induced embolism, unless xylem pressure becomes very negative during the freezing. In this study, we show that conifers experienced freezing-induced embolism when exposed to repeated freeze-thaw cycles and simultaneously to drought. Simulating conditions at the alpine timberline (128 days with freeze-thaw events and thawing rates of up to 9.5 K h(-1) in the xylem of exposed twigs during winter), young trees of Norway spruce [Picea abies (L.) Karst.] and stone pine (Pinus cembra L.) were exposed to 50 and 100 freeze-thaw cycles. This treatment caused a significant increase in embolism rates in drought-stressed samples. Upon 100 freeze-thaw cycles, vulnerability thresholds (50% loss of conductivity) were shifted 1.8 MPa (Norway spruce) and 0.8 MPa (stone pine) towards less negative water potentials. The results demonstrate that freeze-thaw cycles are a possible reason for winter-embolism in conifers observed in several field studies. Freezing-induced embolism may contribute to the altitudinal limits of conifers.
Onyx in Brain Arteriovenous Malformation Embolisation.
Hashim, Hilwati; Muda, A Sobri; Abdul Aziz, Aida; Abdul Hamid, Zuhanis
2016-07-01
Embolisation has long been used as an adjunct to surgical resection in the treatment of brain arteriovenous malformation (bAVM). The most commonly used embolic material, n-butylcyanoacrylate glue, requires experience and skill to handle its quick and unpredictable flow and polymerisation. A new liquid embolic agent, ethylene vinyl alcohol copolymer (Onyx), is less adhesive and polymerises slowly, which provides better control for radiologists performing embolisation. To report our experience in embolisation using Onyx alone or in combination with histoacryl for bAVM embolisation in our tertiary referral centre. We retrospectively reviewed the anatomy, technical conditions, complications and clinical outcome of all bAVM patients embolised at our centre using Onyx alone or in combination with n-butylcyanoacrylate glue. Between 2010 and 2013, 13 patients [6 (46.2%) male; 7 (53.8%) female; aged, 14-57 years] were included, and a total of 31 embolisations were performed. Clinical presentation included hemorrhage [9 (69.2%)], seizures [2 (15.4%)], and headache [2 (15.4%)]. Most AVMs were located in the brain hemispheres [12 (92.3%)] and measured <3 cm [7 (53.8%]. Complete occlusion of the AVM was obtained in 2 (15.4%) patients; 11 (84.6%) patients had partial occlusion [6 (54.5%) had <50% nidus occlusion]. Complications occurred in four procedures involving 3 patients (morbidity, 23.1%). This resulted in the death of 1 patient (mortality, 7.7%) and complete recovery with no disability in 2 patients. The total nidal occlusion achieved herein is comparable to other similar studies. Our morbidity and mortality were higher compared to other studies which may be attributed to the small number of patients. More data is being collected which may better reflect on our experience.
Owa, M; Higashikata, T; Shimada, H; Kitahara, H; Asano, M; Nakayama, J; Hikita, H; Koyama, J; Sakurai, S; Ikeda, S
2000-12-01
A 51-year-old woman presented with progressive right ventricular infundibular wall thickening and outflow obstruction. She had had an aorto-coronary bypass for left main coronary artery disease 1 year after radiation therapy for left mammary cancer. Enhanced computed tomography showed a mass in the right ventricular free wall with no connection to the mediastinum; the tumor extended into the main pulmonary artery, but there was no other evidence of a primary or metastatic tumor. A biopsy specimen was obtained and based on the microscopic and immuno-histochemical findings (vimentin and Kp-1 positive) the diagnosis was primary cardiac malignant fibrous histiocytoma, which is very rare. A cavo-pulmonary artery connection lessened her symptoms, but embolization of the coronary artery to try and to reduce the mass had minimal effect. Four months after the tumor was diagnosed she died of extended pulmonary artery obstruction.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jud, Philipp, E-mail: philipp.jud@medunigraz.at; Portugaller, Rupert; Bohlsen, Dennis
A 55-year-old male with peripheral arterial disease underwent angioplasty of the right lower limb arteries via antegrade femoral access. Angio-Seal{sup ®} closure device was used to treat the puncture site, whereby the intravascular sealing anchor accidentally embolized into the malleolar region of the right posterior tibial artery. Successful retrieval of the anchor was accomplished by a SpiderFX embolic protection device. This technique may be a useful approach to retrieve embolized foreign bodies via endovascular access.
Selective management of embolized intracardiac missiles.
Gandhi, S K; Marts, B C; Mistry, B M; Brown, J W; Durham, R M; Mazuski, J E
1996-07-01
Intracardiac projectiles are occasionally found in stable patients who have sustained penetrating trauma. These missiles may arise from embolization from a peripheral injury site. We describe 3 patients with embolized intracardiac projectiles. The diagnosis was suggested by the presence of a foreign body within the cardiac silhouette on chest roentgenograms and was confirmed using fluoroscopy, echocardiography, or computed tomography. The management of embolized intracardiac missiles should be individualized to each patient. All of our patients had fixed intracavitary right-sided missiles and were successfully managed expectantly.
The Pathophysiology of Decompression Sickness and the Effects of Doppler Detectable Bubbles.
1980-12-18
Doppler Ultrasound and a calibrated 6 1 Venous Gas Embol i Scale. C. Electronic Counting of Doppler Bubble Signals 72 £ III. Pulmonary Embolism Studies...IA. Background 75 B. Right Ventricular Systolic Pressure following Gas 81 Embolization and Venous Gas Phase Content IC. Effects of Pulmonary Gas... Embolism on the Development 9 of Limb-Bend Decompression Sickness 1 IV. Gas Phase Formation in Highly Perfused Tissues IA. Renal 9 B. Cerebral 9 1 I I V
1980-06-01
fat embolism after long bone fractures . Studies have never clearly resolved the issue over origin of the fat and some believe it is tissue embolism ...C., Hudson, T. L., Irvin, R. W., Kelly, T. and Hardaway, R. M.: Inapparent hypoxemia in casualties with wounded limbs: pulmonary fat embolism ? Ann...J. Surg. Res. 9:685, 1969. 9. Collins, J. A. and Caldwell, M. C.: The relationship of depot fat embolism to pulmonary structure and function in
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pieper, Claus C., E-mail: claus.christian.pieper@ukb.uni-bonn.de; Meyer, Carsten, E-mail: Carsten.Meyer@ukb.uni-bonn.de; Vollmar, Brigitte, E-mail: brigitte.vollmar@med.uni-rostock.de
BackgroundThis study aimed to evaluate the embolic properties, time to reperfusion, and histologic changes in temporary embolization of liver tissue with degradable starch microspheres (DSM) in a swine model.MethodsIn four adult minipigs, DSMs were injected into the right or left hepatic artery on the lobar level until complete stasis of the blood flow was detectable angiographically. The time required to complete angiographically determined reperfusion was noted. The animals were killed 3 h after complete reperfusion, and samples were taken from the liver. Histologic examinations of the embolized liver parenchyma and untreated tissue were performed.ResultsHepatic arterial embolization using DSMs was technically successfulmore » in all cases, with complete blood flow stasis shown by control angiography. A single vial of DSMs (450 mg/7.5 ml) was sufficient to embolize a whole liver lobe in all cases. Angiography showed complete reconstitution of hepatic arterial perfusion after a mean time to reperfusion of 32 ± 6.1 min (range, 26–39 min). Hematoxylin and eosin staining showed no histologically detectable differences between untreated tissue and parenchyma embolized with DSMs except for mild sinusoidal congestion in one case. Indirect in situ DNA nick end labeling staining (TUNEL) showed only single positive hepatocytes, indicating apoptosis.ConclusionTemporary embolization of the hepatic artery using DSMs is feasible with complete reperfusion after 30 min in pigs. Even after complete arterial blood flow stasis, no extensive tissue damage to the embolized liver parenchyma was observed at histologic examinations in this short-term study.« less
Preoperative Embolization of Skull Base Meningiomas: Outcomes in the Onyx Era.
Przybylowski, Colin J; Baranoski, Jacob F; See, Alfred P; Flores, Bruno C; Almefty, Rami O; Ding, Dale; Chapple, Kristina M; Sanai, Nader; Ducruet, Andrew F; Albuquerque, Felipe C
2018-05-09
Preoperative embolization may facilitate skull base meningioma resection, but its safety and efficacy in the Onyx era have not been investigated. In this retrospective cohort study, we evaluated the outcomes of preoperative embolization of skull base meningiomas using Onyx as the primary embolysate. We queried an endovascular database for patients with skull base meningiomas who underwent preoperative embolization at our institution in 2007-2017. Patient, tumor, procedure, and outcome data were analyzed. Twenty-eight patients (28 meningiomas) underwent successful preoperative meningioma embolization. The mean patient age ± SD was 56 ± 13 years, and 18 patients (64%) were women. The mean tumor size was 49 cm 3 . There were 1, 2, or 3 arterial pedicles embolized in 21 cases (75%), 6 cases (21%), and 1 case (4%), respectively. The embolized pedicles included branches of the middle meningeal artery in 19 cases (68%), the internal maxillary artery in 8 cases (29%), the ascending pharyngeal artery in 2 cases (7%), and the posterior auricular, ophthalmic, occipital, and anterior cerebral arteries in 1 case each (4%). The embolysates used were Onyx alone in 20 cases (71%), n-butyl cyanoacrylate alone in 3 cases (11%), coils/particles and Onyx/n-butyl cyanoacrylate in 2 cases each (7%), and Onyx and coils in 1 case (4%). The median degree of tumor devascularization was 60%. Significant neurologic morbidity occurred in 1 patient (4%) who developed symptomatic peritumoral edema after Onyx embolization. For appropriately selected skull base meningiomas supplied by dura mater-based arterial pedicles without distal cranial nerve supply, preoperative embolization with current embolysate technology affords substantial tumor devascularization with a low complication rate. Copyright © 2018 Elsevier Inc. All rights reserved.
Knipfer, Thorsten; Cuneo, Italo F; Brodersen, Craig R; McElrone, Andrew J
2016-06-01
Gas embolisms formed during drought can disrupt long-distance water transport through plant xylem vessels, but some species have the ability to remove these blockages. Despite evidence suggesting that embolism removal is linked to the presence of vessel-associated parenchyma, the underlying mechanism remains controversial and is thought to involve positive pressure generated by roots. Here, we used in situ x-ray microtomography on excised grapevine stems to determine if embolism removal is possible without root pressure, and if the embolism formation/removal affects vessel functional status after sample excision. Our data show that embolism removal in excised stems was driven by water droplet growth and was qualitatively identical to refilling in intact plants. When stem segments were rehydrated with H2O after excision, vessel refilling occurred rapidly (<1 h). The refilling process was substantially slower when polyethylene glycol was added to the H2O source, thereby providing new support for an osmotically driven refilling mechanism. In contrast, segments not supplied with H2O showed no refilling and increased embolism formation. Dynamic changes in liquid/wall contact angles indicated that the processes of embolism removal (i.e. vessel refilling) by water influx and embolism formation by water efflux were directly linked to the activity of vessel-associated living tissue. Overall, our results emphasize that root pressure is not required as a driving force for vessel refilling, and care should be taken when performing hydraulics measurements on excised plant organs containing living vessel-associated tissue, because the vessel behavior may not be static. © 2016 American Society of Plant Biologists. All Rights Reserved.
Knipfer, Thorsten; Cuneo, Italo F.; Brodersen, Craig R.; McElrone, Andrew J.
2016-01-01
Gas embolisms formed during drought can disrupt long-distance water transport through plant xylem vessels, but some species have the ability to remove these blockages. Despite evidence suggesting that embolism removal is linked to the presence of vessel-associated parenchyma, the underlying mechanism remains controversial and is thought to involve positive pressure generated by roots. Here, we used in situ x-ray microtomography on excised grapevine stems to determine if embolism removal is possible without root pressure, and if the embolism formation/removal affects vessel functional status after sample excision. Our data show that embolism removal in excised stems was driven by water droplet growth and was qualitatively identical to refilling in intact plants. When stem segments were rehydrated with H2O after excision, vessel refilling occurred rapidly (<1 h). The refilling process was substantially slower when polyethylene glycol was added to the H2O source, thereby providing new support for an osmotically driven refilling mechanism. In contrast, segments not supplied with H2O showed no refilling and increased embolism formation. Dynamic changes in liquid/wall contact angles indicated that the processes of embolism removal (i.e. vessel refilling) by water influx and embolism formation by water efflux were directly linked to the activity of vessel-associated living tissue. Overall, our results emphasize that root pressure is not required as a driving force for vessel refilling, and care should be taken when performing hydraulics measurements on excised plant organs containing living vessel-associated tissue, because the vessel behavior may not be static. PMID:27208267
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rampoldi, Antonio; Barbosa, Fabiane, E-mail: fabiane001@hotmail.com; Secco, Silvia
PurposeTo prospectively assess discontinuation of indwelling bladder catheterization (IBC) and relief of lower urinary tract symptoms (LUTS) due to benign prostatic hyperplasia (BPH) following prostate artery embolization (PAE) in poor surgical candidates.MethodsPatients ineligible for surgical intervention were offered PAE after at least 1 month of IBC for management of urinary retention secondary to BPH; exclusion criteria for PAE included eligibility for surgery, active bladder cancer or known prostate cancer. Embolization technical and clinical success were defined as bilateral prostate embolization and removal of IBC, respectively. Patients were followed for at least 6 months and evaluated for International Prostate Symptom Score, quality ofmore » life, prostate size and uroflowmetric parameters.ResultsA total of 43 patients were enrolled; bilateral embolization was performed in 33 (76.7%), unilateral embolization was performed in 8 (18.6%), and two patients could not be embolized due to tortuous and atherosclerotic pelvic vasculature (4.7%). Among the patients who were embolized, mean prostate size decreased from 75.6 ± 33.2 to 63.0 ± 23.2 g (sign rank p = 0.0001, mean reduction of 19.6 ± 17.3%), and IBC removal was achieved in 33 patients (80.5%). Clavien II complications were reported in nine patients (21.9%) and included urinary tract infection (three patients, 7.3%) and recurrent acute urinary retention (six patients, 14.6%). Nine patients (22.0%) experienced post-embolization syndrome.ConclusionsPAE is a safe and feasible for the relief of LUTS and IBC in highly comorbid patients without surgical treatment options.« less
Electrocardiographic findings in Emergency Department patients with pulmonary embolism.
Richman, Peter B; Loutfi, Hassan; Lester, Steven J; Cambell, Patricia; Matthews, Jessica; Friese, Jeremy; Wood, Joseph; Kasper, David; Chen, Frederick; Mandell, Mark
2004-08-01
To assess the pre-study, null hypothesis that there is no difference in the electrocardiogram (EKG) findings for Emergency Department (ED) patients who rule in vs. rule out for suspected pulmonary embolism, a retrospective review of a cohort of patients with pulmonary embolism and their controls was conducted in an academic, suburban ED. Patients who were evaluated in the ED during a one-year study period for symptoms suggestive of pulmonary embolism were eligible for inclusion. All patients with pulmonary embolism and sex- and age-matched controls comprised the final study groups. Two board-certified cardiologists reviewed each patient's EKG. There were 350 eligible patients identified; 49 patients with pulmonary embolism and 49 controls were entered into the study. The most common rhythm observed in both groups was normal sinus rhythm (67.3% cases vs. 68.6 % controls; p = 1.0). Abnormalities believed to be associated with pulmonary embolism occurred with similar frequency in both case and control groups (sinus tachycardia [18.8 % vs. 11.8%, respectively; p = 0.40]), incomplete right bundle branch block (4.2% vs. 0.0%, respectively; p = 0.24), complete right bundle branch block (4.2% vs. 6.0, respectively; p = 1.0), S1Q3T3 pattern (2.1 vs. 0.0, respectively; p = 0.49), S1Q3 pattern (0.0 vs. 0.0), and extreme right axis (0.0 vs. 0.0). New EKG changes were identified more frequently for patients with pulmonary embolism (33.3% vs. 12.5% controls; p = 0.03), but specific findings were rarely different between cases and controls. In our cohort of ED patients, we did not identify EKG features that are likely to help distinguish patients with pulmonary embolism from those who rule out for the disease.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ikoma, Akira; Kawai, Nobuyuki; Sato, Morio, E-mail: morisato@wakayama-med.ac.jp
2010-10-15
This study was designed to assess the safety of transcatheter arterial embolization (TAE) with n-butyl cyanoacrylate-lipiodol (NBCA-Lp) for the large bowel and to investigate the vital response to NBCA-Lp in a swine model. In nine swine, nine arteries nourishing the colon were embolized with NBCA-Lp (1 ml of NBCA mixed with 4 ml of lipiodol): sigmoid-rectal branch artery in six swine, right colic branch artery in two, and middle colic branch artery in one. The amount of NBCA-Lp was 0.1-0.4 ml. Sacrifice was conducted 3 days after TAE to identify histological infarction. Classification was conducted retrospectively: group A, vasa rectamore » without NBCA-Lp embolization despite TAE; group B, three or fewer vasa recta with NBCA-Lp embolization; and group C, five or more vasa recta with NBCA-Lp embolization. In one swine in group A, no necrotic focus was observed. In group B, three of four swine experienced no ischemic damage. The remaining one swine experienced necrosis of mucosal and submucosal layers in one-fourth of the circumference. In group C, all four swine with marginal artery and five vasa recta or more embolized experienced total necrosis of mucosa, submucosa, and smooth muscle layers of the whole colonic circumference. Significant difference on the extent of ischemic damage was observed between groups B and C (P < 0.05). Microscopically, NBCA-Lp induced acute vasculitis. Embolization of three or fewer vasa recta with NBCA-Lp induced no ischemic damage or limited necrosis, whereas embolization of five or more vasa recta with NBCA-Lp induced extensive necrosis.« less
Luo, Xiaoyun; Zhang, Fuxian; Zhang, Changming; Hu, Lu; Feng, Yaping; Liang, Gangzhu; Niu, Luyuan; Zhang, Huan; Cheng, Long; Qi, Haoshan
2015-08-01
To identify the risk factors associated with the severity of pulmonary embolism among patients with deep venous thrombosis of lower extremities. This prospective study enrolled 208 patients with acute deep venous thrombosis to screen for pulmonary embolism between July 2010 and July 2012 in Beijing Shijitan Hospital. There were 101 male and 107 female patients, with a mean age of (59 ± 16) years. Gender, age, extension, side of lower extremities of deep venous thrombosis was analyzed by χ² test. Ordinal Logistic regression was used to determine risk factors associated with severity of pulmonary embolism. There were 83 patients with iliofemoral deep venous thrombosis, 102 patients with femoropopliteal and 23 patients with calf deep venous thrombosis. Pulmonary embolism was detected in 70 patients with the incidence of 33.7%. Pulmonary embolism was significantly correlated with extension (χ² = 17.286, P = 0.004) and sides (χ² = 15.602, P = 0.008) of deep venous thrombosis, not with age (χ² = 7.099, P = 0.260), gender (χ² = 7.014, P = 0.067), thrombotic risk factors (χ² = 3.335, P = 0.345) in univariate analysis. Results of multivariate ordinal logistic regression showed that iliofemoral vein thrombosis (OR = 6.172, 95% CI: 1.590 to 23.975, P = 0.009) and bilateral venous thrombosis (OR = 7.140, 95% CI: 2.406 to 24.730, P = 0.001) are associated with more serious pulmonary embolism. Incidence of pulmonary embolism is still high in patients with deep venous thrombosis. Extensive iliofemoral and bilateral vein thrombosis may increase risk of severity of pulmonary embolism. Clinicians should pay more attention to these high-risk patients.
Li, Fenghe; Wang, Xuehu; Huang, Wen; Ren, Wei; Cheng, Jun; Zhang, Mao; Zhao, Yu
2014-08-01
The aim of our study is to investigate the prevalence of silent pulmonary embolism in patients with deep venous thrombosis in the lower limbs and to evaluate the associated risk factors. A total of 322 patients with acute deep venous thrombosis confirmed by CT venography or Doppler ultrasonography were studied. The diagnosis of silent pulmonary embolism was established by computed tomography pulmonary arteriography (CTPA). The association between covariates and the prevalence of silent pulmonary embolism in patients with deep venous thrombosis in lower limbs were assessed using chi-square test and multivariable regression. The incidence of silent pulmonary embolism was 33.5% (108 in 322 patients) in all patients with deep venous thrombosis in lower limbs. Chi-square test showed male gender, the right lower limb, proximal location of the thrombus, unprovoked venous thrombosis and coexisting heart diseases were related to a higher incidence of silent pulmonary embolism in patients with deep venous thrombosis in lower limbs. The multivariate regression analysis confirmed that the risk factors associated with silent pulmonary embolism in deep venous thrombosis patients included the right side and proximal location of the thrombus (odds ratio: 2.023, 95% CI: 1.215-3.368; odds ratio: 3.610, 95% CI: 1.772-7.354), unprovoked venous thrombosis (odds ratio: 2.037, 95% CI: 1.188-3.493), coexisting heart diseases (odds ratio: 4.507, 95% CI: 2.667-7.618). Silent pulmonary embolism occurred frequently in patients with deep venous thrombosis in lower limbs. The right side, the proximal location of the thrombus, unprovoked venous thrombosis and coexisting heart diseases increased the risk for the occurrence of silent pulmonary embolism. © The Author(s) 2013 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
Embolization techniques for high-flow arteriovenous malformations with a dominant outflow vein.
Conway, Allan M; Qato, Khalil; Drury, Jennifer; Rosen, Robert J
2015-04-01
The aim of this study was to assess the management and outcomes of arteriovenous malformations (AVMs) with a dominant outflow vein (DOV) treated with retrograde venous embolization. A retrospective review was performed from November 2010 to May 2014 on all patients with a high-flow AVM and associated DOV who underwent transvenous embolization of the DOV. Indications, techniques, complications, and outcomes were reviewed. Fourteen patients (five male; 36%) underwent transvenous embolization of high-flow AVMs with a DOV. Median age was 41.6 years (15.7-65.8 years). The AVM was located on an extremity in eight patients (57%) and in the pelvis in six patients (43%). The indication for the procedure was pain in 11 patients (79%), swelling in 3 patients (21%), a nonhealing wound in 1 patient (7%), and impotence in 1 patient (7%). The median number of prior procedures to treat the AVM was 2.5 (0-13). Transvenous embolization with coils was performed in 13 patients (93%). The Amplatzer vascular plug and Amplatzer septal occluder (St. Jude Medical, St. Paul, Minn) were used in four patients (29%). Concurrent percutaneous puncture embolization of the AVM nidus was used in seven patients (50%) and transcatheter arterial embolization in eight patients (57%). Technical angiographic success was seen in all patients. Five patients (36%) experienced a complete response to treatment, whereas eight (57%) experienced a partial response. Seven patients (50%) required further procedures for residual symptoms. AVMs with a DOV can be successfully treated by a transvenous approach. Percutaneous puncture embolization of the nidus or draining vein and transcatheter arterial embolization may assist in reducing flow. Copyright © 2015 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.
Bilateral shotgun pellet pulmonary emboli
Huebner, Stephen; Ali, Sayed
2012-01-01
Intravascular migration of bullets and other foreign bodies is a rare but known complication of penetrating trauma. Missile embolization can represent a diagnostic challenge because it may present in various and unexpected ways. We present the case of a 54-year-old female who sustained shotgun pellet emboli to the pulmonary arteries following a left upper extremity gunshot wound and related vascular surgery. The case illustrates bilateral embolization, and the embolic events occurred following surgery. Embolization should be considered in evaluating patients with gunshot wounds, particularly if there are anomalous symptoms or the projectile is not found in the original, or expected, location. Close attention to the location of the foreign bodies on serial radiographs may reveal the diagnosis of intravascular embolization. PMID:22690290
Traumatic Laceration of the Cisterna Chyli Treated by Lymphangiography and Percutaneous Embolization
DOE Office of Scientific and Technical Information (OSTI.GOV)
Allison, Stephen, E-mail: sallison@uw.edu; Rainey, Matthew, E-mail: mrainey4@uw.edu; Aarabi, Shahram, E-mail: shahram@uw.edu
Lymphangiography and percutaneous embolization has been described for the treatment of thoracic duct injury, usually occurring in the postsurgical period. We report a case of a traumatic gunshot-induced massive chylothorax. Inguinal lymphangiogram was performed demonstrating the site of injury at the cisterna chyli. The cisterna chyli was successfully accessed via a percutaneous approach, and embolization was performed. Chylothorax immediately resolved after two rounds of embolization. Although lymphangiography has been traditionally challenging and cumbersome, because of the need for pedal lymph access, the recent use of inguinal lymphangiography has made this technique more practical. Techniques used for embolization of the thoracicmore » duct may be applied to the cisterna chyli, which is much more challenging to treat surgically.« less
21 CFR 870.3300 - Vascular embolization device.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Vascular embolization device. 870.3300 Section 870.3300 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3300 Vascular embolization...
Splenic arteriogastric fistula from plication of a gastric ulcer. Therapeutic embolization.
Morse, S S; Siskind, B N; Horowitz, N R; Strauss, E B
1987-08-01
Massive upper gastrointestinal hemorrhage occurred in a 66-year-old man 18 days after suture plication of a giant gastric ulcer. Arteriography revealed a splenic arteriogastric fistula. Therapeutic embolization with tissue adhesive (bucrylate) successfully controlled hemorrhage after failure of attempted particulate embolization.
21 CFR 870.3300 - Vascular embolization device.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Vascular embolization device. 870.3300 Section 870.3300 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3300 Vascular embolization...
Morrison, Rachel; Thompson, James; Bird, Luke; Hill, Mark A; Townley, Helen
2015-08-01
Radiopaque and fluorescent embolic particles have been synthesized and characterised to match the size of vasculature found in tumours to ensure effective occlusion of the vessels. A literature search showed that the majority of vessels surrounding a tumour were less than 50 µm and therefore polydispersed polystyrene particles with a peak size of 50 µm have been synthesised. The embolic particles contain 5-8 nm amorphous tantalum oxide nanoparticles which provide X-ray contrast. Embolic particles containing up to 9.4 wt% tantalum oxide were prepared and showed significant contrast compared to the undoped polystyrene particles. The X-ray contrast of the embolic particles was shown to be linear (R(2) = 0.9) with respect to the concentration of incorporated tantalum nanoparticles. A model was developed which showed that seventy-five 50 µm embolic particles containing 10% tantalum oxide could provide the same contrast as 5 cm of bone. Therefore, the synthesized particles would provide sufficient X-ray contrast to enable visualisation within a tumour.
He, Xiao-Yan; Zhang, Guo-Zhong; Li, Ming-Zhou; Wang, Gang; Liu, Dan; Qi, Song-Tao; Li, Wei-Guang; Feng, Wen-Feng
2016-03-01
To compare the efficacy, clinical characteristics, safety, injection time and radiation exposure of Onyx embolization using a long-distance injection method and routine injection method for management of dural arteriovenous fistula (DAVF). The clinical data were retrospectively analyzed in 59 patients with DAVF treated with Onyx embolization using long-distance injection method (28 patients) and routine injection method (31 patients). The efficacy, safety, injection time and radiation exposure during Onyx embolization were compared between the two injections methods. The average radiation dose exposure to the surgeon per procedure was significantly lower in the long-distance injection group than in the routine group. The injection time (P=0.53), injection volume (P=0.78), number of supply arteries (P=0.80), Cognard types (P=0.67), and effect of embolization (P=0.88) were all similar between the two groups. Endovaseular treatment of intracranial DAVF with Onyx embolization using the long-distance injection method is feasible, safe and effective and can reduce the radiation exposure to the surgeon.
Cranial Nerve Palsy after Onyx Embolization as a Treatment for Cerebral Vascular Malformation
Lee, Jong Min; Whang, Kum; Cho, Sung Min; Kim, Jong Yeon; Oh, Ji Woong; Koo, Youn Moo; Hu, Chul; Pyen, Jinsoo
2017-01-01
The Onyx liquid embolic system is a relatively safe and commonly used treatment for vascular malformations, such as arteriovenous fistulas and arteriovenous malformations. However, studies on possible complications after Onyx embolization in patients with vascular malformations are limited, and the occurrence of cranial nerve palsy is occasionally reported. Here we report the progress of two different types of cranial nerve palsy that can occur after embolization. In both cases, Onyx embolization was performed to treat vascular malformations and ipsilateral oculomotor and facial nerve palsies were observed. Both patients were treated with steroids and exhibited symptom improvement after several months. The most common types of neuropathy that can occur after Onyx embolization are facial nerve palsy and trigeminal neuralgia. Although the mechanisms underlying these neuropathies are not clear, they may involve traction injuries sustained while extracting the microcatheter, mass effects resulting from thrombi and edema, or Onyx reflux into the vasa nervorum. In most cases, the neuropathy spontaneously resolves several months following the procedure. PMID:29159152
Cranial Nerve Palsy after Onyx Embolization as a Treatment for Cerebral Vascular Malformation.
Lee, Jong Min; Whang, Kum; Cho, Sung Min; Kim, Jong Yeon; Oh, Ji Woong; Koo, Youn Moo; Hu, Chul; Pyen, Jinsoo; Choi, Jong Wook
2017-09-01
The Onyx liquid embolic system is a relatively safe and commonly used treatment for vascular malformations, such as arteriovenous fistulas and arteriovenous malformations. However, studies on possible complications after Onyx embolization in patients with vascular malformations are limited, and the occurrence of cranial nerve palsy is occasionally reported. Here we report the progress of two different types of cranial nerve palsy that can occur after embolization. In both cases, Onyx embolization was performed to treat vascular malformations and ipsilateral oculomotor and facial nerve palsies were observed. Both patients were treated with steroids and exhibited symptom improvement after several months. The most common types of neuropathy that can occur after Onyx embolization are facial nerve palsy and trigeminal neuralgia. Although the mechanisms underlying these neuropathies are not clear, they may involve traction injuries sustained while extracting the microcatheter, mass effects resulting from thrombi and edema, or Onyx reflux into the vasa nervorum. In most cases, the neuropathy spontaneously resolves several months following the procedure.
New advances in lower gastrointestinal bleeding management with embolotherapy
Ierardi, Anna Maria; Urbano, Josè; De Marchi, Giuseppe; Micieli, Camilla; Duka, Ejona; Iacobellis, Francesca; Fontana, Federico
2016-01-01
Lower gastrointestinal bleeding (LGIB) is associated with high morbidity and mortality. Embolization is currently proposed as the first step in the treatment of acute, life-threatening LGIB, when endoscopic approach is not possible or is unsuccessful. Like most procedures performed in emergency setting, time represents a significant factor influencing outcome. Modern tools permit identifying and reaching the bleeding site faster than two-dimensional angiography. Non-selective cone-beam CT arteriography can identify a damaged vessel. Moreover, sophisticated software able to detect the vessel may facilitate direct placement of a microcatheter into the culprit vessel without the need for sequential angiography. A further important aspect is the use of an appropriate technique of embolization and a safe and effective embolic agent. Current evidence shows the use of detachable coils (with or without a triaxial system) and liquid embolics has proven advantages compared with other embolic agents. The present article analyses these modern tools, making embolization of acute LGIB safer and more effective. PMID:26764281
Analysis of weight changes after left gastric artery embolization in a cancer-naive population
Kim, David J.; Raman, Hari S.; Salter, Amber; Ramaswamy, Raja; Gunn, Andrew J.; Weiss, Clifford R.; Akinwande, Olaguoke
2018-01-01
PURPOSE We aimed to evaluate weight changes after left gastric artery (LGA) embolization in a retrospective cancer-naive cohort. METHODS A retrospective study was conducted to identify patients who underwent LGA embolization for gastrointestinal bleeding (GI). Patients with known cancer diagnoses at the time of LGA embolization were excluded. Pre- and postprocedure weights were assessed. Statistical analysis was performed using paired t-test and Wilcoxon signed-rank test. RESULTS A total of 39 patients were identified. In 21 patients who had documented pre- and postprocedural weights, a median of 16.3 kg weight loss (P = 0.045) was observed over a median time of 12 months (range, 2–72). In patients who had pre- and postprocedure endoscopies (n=6), 2 had worsening ulcers following LGA embolization and 4 had stable or no abnormal findings. CONCLUSION Our preliminary observation suggests that LGA embolization is well tolerated and results in unintended weight loss. Larger studies are needed to confirm these preliminary findings. PMID:29757147
Coil occlusion of residual shunts after surgical closure of patent ductus arteriosus.
Fujii, Yoko; Keene, Bruce W; Mathews, Kyle G; Atkins, Clarke E; Defrancesco, Teresa C; Hardie, Elizabeth M; Wakao, Yoshito
2006-12-01
OBJECTIVE; To describe use of coil embolization to occlude residual flow through a patent ductus arteriosus (PDA) after incomplete surgical ligation. Clinical study. Dogs (n=4) with continuous murmur after surgical ligation of PDA. After PDA ligation, residual ductal flow through the PDA was visible on color-flow Doppler examination and left ventricular end-diastolic diameter remained increased. Coil embolization by an arterial approach was performed to achieve complete occlusion of the PDA. Embolization coils were delivered without complications and hemodynamically successful occlusion was achieved. Doppler-visible flow resolved in 2 dogs within 3 months after embolization. Left ventricular end-diastolic diameter indexed to body weight decreased in all dogs. Transcatheter coil embolization appears to be a safe and minimally invasive procedure for complete occlusion of residual PDA flow after incomplete surgical ligation. Transcatheter coil embolization should be considered for correction of hemodynamically significant residual shunts in dogs that have incomplete PDA occlusion after open surgical ligation.
Caretta, Giorgio; Robba, Debora; Bonadei, Ivano; Teli, Melissa; Fontanella, Benedetta; Farina, Davide; Raddino, Riccardo; Cas, Livio Dei
2009-01-01
Paradoxical embolism is defined as a systemic arterial embolism requiring the passage of a venous thrombus into the arterial circulatory system through a right-to-left shunt. It is a relatively rare phenomenon, representing about 2% of all cases of arterial embolism. We report a case of a 79-years-old woman admitted to hospital because of dyspnea and lower left limb pain. CT scan revealed multiple thrombi to kidney, lower limb and superior mesenteric artery during acute pulmonary embolism. Echocardiogram documented a patent foramen ovale with a right-to-left shunt. The patient was treated with thrombolytic therapy and heparin with progressive improvement of symptoms and resolution of pulmonary embolism and peripheral thrombosis. Patent foramen ovale closure was not performed because a life-long anticoagulation therapy was necessary, a tunnel-type patent foramen ovale may increases difficulty in realizing device implantation and there are no clear evidence-based guidelines to date addressing treatment in presence of a patent foramen ovale. PMID:19918422
Loffroy, Romaric; Guiu, Boris; Mezzetta, Lise; Minello, Anne; Michiels, Christophe; Jouve, Jean-Louis; Cheynel, Nicolas; Rat, Patrick; Cercueil, Jean-Pierre; Krausé, Denis
2009-01-01
BACKGROUND AND AIM: Severe bleeding from gastrointestinal ulcers is a life-threatening event that is difficult to manage when endoscopic treatment fails. Transcatheter embolization has been suggested as an alternative treatment in this situation. The present study reports on the efficacy and long-term outcomes of transcatheter embolization after failed endoscopic treatments were assessed in high-operative-risk patients. METHODS: A retrospective review of 60 consecutive emergency embolization procedures in hemodynamically unstable patients (41 men, 19 women; mean [±SD] age 69.4±15 years) was conducted. Patients were referred for selective angiography between 1999 and 2008 after failed endoscopic treatment of massive bleeding from gastrointestinal ulcers. Mean follow-up was 22 months. RESULTS: Embolization was feasible and successful in 57 patients. Sandwich coiling of the gastroduodenal artery was used in 34 patients, and superselective occlusion of the terminal feeding artery (with glue, coils or gelatin particles) was used in 23 patients. Early rebleeding occurred in 16 patients and was managed with endoscopy (n=8), reembolization (n=3) or surgery (n=5). No major embolization-related complications occurred. Sixteen patients died within 30 days after embolization (including three who died from rebleeding) and 11 died thereafter. No late bleeding recurrences were reported. CONCLUSIONS: Selective angiographic embolization is safe and effective for controlling life-threatening bleeding from gastroduodenal ulcers. The procedure usually obviates the need for emergency surgery in these high-risk patients. Survival depends chiefly on underlying conditions. PMID:19214287
Critical potential of early cardiac surgery for infective endocarditis with cardio-embolic strokes.
Suzuki, Makoto; Takanashi, Shuichiro; Ohshima, Yutaro; Nagatomo, Yuji; Seki, Atsushi; Takamisawa, Itaru; Tobaru, Tetsuya; Naito, Kazuhiro; Kin, Hajime; Umemura, Jun; Takayama, Morimasa; Sumiyoshi, Tetsuya; Tomoike, Hitonobu
2017-01-15
Early cardiac surgery may have a trade-off between stabilized hemodynamics with controlled infection and a risk of peri-operative death in patients with infective endocarditis (IE) complicated with cardio-embolic strokes. We retrospectively studied clinical characteristics and outcomes in 68 consecutive patients with IE (mean age, 58±3years, 62% male) who admitted in our institute during June 2013 and August 2015. Cardio-embolic strokes were noted in 37% of patients (n=25) with IE and overall in-hospital mortality was 4 times higher in IE with cardio-embolic strokes than IE with an absence of strokes (n=43) (20% vs. 4.7%, p=0.045). Bacteremia of Staphylococcus aureus (p=0.021) and a complication of cardio-embolic strokes (p=0.031) were independently associated with in-hospital death in those with IE. However, in-hospital mortality was quite low in 19 with early cardiac surgery compared with 6 with conventional treatment in those with cardio-embolic strokes (11% vs. 50%, p=0.035). Multivariate logistic analysis demonstrated that lack of early cardiac surgery (p=0.014), a complication of cerebral hemorrhage (p=0.002), and a presence of refractory heart failure (p=0.047) were independently associated with in-hospital death in those with IE complicated with cardio-embolic strokes. Early cardiac surgery may provide clinical advantages overcoming peri-operative risks in those with IE complicated with cardio-embolic strokes. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Thiex, R; Wu, I; Mulliken, J B; Greene, A K; Rahbar, R; Orbach, D B
2011-01-01
Onyx was developed for embolization of central nervous system AVMs but is increasingly used extracranially because of its unique physical properties. We review our experience and results with the use of Onyx for the treatment of fast-flow extracranial vascular lesions. We retrospectively analyzed clinical and imaging records of 22 patients who underwent 71 extracranial embolizations from March 2007 through January 2010. The diagnoses were the following: cervicofacial AVM (n = 18), traumatic fistula (n = 3), and vessel laceration (n = 1). In 62 of 71 procedures (87%), Onyx was the sole embolic agent; it was delivered transarterially in 67/71 and percutaneously in 4/71 procedures. Clinical goals included amelioration of pain and control of bleeding. The clinical efficacy of embolization was judged by symptom control, and adverse events were assessed by clinical examination and history, both postembolization and 4 weeks postprocedure. Cessation of acute bleeding was achieved in 13/14 cases, with 1 case of immediate recurrent massive epistaxis prompting reintubation and further embolization. Control of subacute bleeding episodes and pain was achieved for all patients. Following staged embolization, 7 patients underwent surgical resection without significant blood loss. Surgeons reported high satisfaction with the intraoperative handling properties of Onyx. Transient swelling, local tenderness, or numbness was encountered after 7 procedures. There were no stuck catheters, vessel dissections, or vessel ruptures and no skin discoloration. Staged Onyx embolization was clinically efficacious in managing extracranial fast-flow vascular malformations and lesions, with low associated morbidity.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Owen, Richard J., E-mail: drrichardowen@tbwifi.ca; Nation, Patrick N.; Polakowski, Robert
Introduction: This study evaluated the safety, effectiveness, and biodegradation of a new embolic agent, Occlusin Trade-Mark-Sign 503 Artificial Embolization Device (OCL 503). The agent consists of biodegradable poly-lactic-co-glycolic acid microspheres (150-212 {mu}m) coated with type I bovine collagen and was compared with Embosphere{sup Registered-Sign} Microspheres (300-500 {mu}m) in this controlled study of uterine artery embolization (UAE) in sheep. Methods: Unilateral UAE was performed in 32 adult ewes randomly assigned. Vessels were embolized to effective stasis. The cohort was divided into four groups, which were sacrificed at 1, 3, 6, and 12 months. Results: Both agents were 100% effective in achievingmore » stasis. At 6 months, all OCL 503-treated arteries were occluded, the microspheres degraded with time, and at 12 months all four animals examined demonstrated recanalization. OCL 503 was found in the untreated uterine artery in one animal with no other evidence of non target embolization. In the Embosphere-treated group, all vessels remained occluded and microspheres were detected in the contralateral uterine artery in 6 of 15 examined vessels and in 10 vaginal, 2 ovarian, and 1 vesical artery. No procedural-related complications were seen in either group. Conclusions: OCL 503 is as effective an embolic agent as Embosphere{sup Registered-Sign} Microspheres when embolizing ovine uterine arteries and resorbs with time, allowing recanalization of the treated arteries. No device-related issues or adverse events were observed.« less
USDA-ARS?s Scientific Manuscript database
Water moves through plants under tension and in a thermodynamically metastable state, leaving the non-living vessels that transport this water vulnerable to blockage by gas embolisms. Failure to re-establish flow in embolized vessels can lead to systemic loss of hydraulic conductivity and ultimately...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Helmberger, Thomas K.; Roth, Ute; Empen, Klaus
2002-08-15
We report on a rare, acute, life-threatening complication during percutaneous thermal therapy for hepatic metastases. Massive cardiac air embolism occurred during a maneuver of deep inspiration after the dislodgement of an introducer sheath into a hepatic vein. The subsequent cardiac arrest was treated successfully by immediate transthoracic evacuation of the air by needle aspiration followed by electrical defibrillation. In procedures that may be complicated by gas embolism, cardiopulmonary resuscitation should not be initiated before considering the likelihood of air embolism, and eventually aspiration of the gas.
Renoduodenal Fistula After Transcatheter Embolization of Renal Angiomyolipoma
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sheth, Rahul A.; Feldman, Adam S.; Walker, T. Gregory, E-mail: tgwalker@partners.org
Transcatheter embolization of renal angiomyolipomas is a routinely performed, nephron-sparing procedure with a favorable safety profile. Complications from this procedure are typically minor in severity, with postembolization syndrome the most common minor complication. Abscess formation is a recognized but uncommon major complication of this procedure and is presumably due to superinfection of the infarcted tissue after arterial embolization. In this case report, we describe the formation of a renoduodenal fistula after embolization of an angiomyolipoma, complicated by intracranial abscess formation and requiring multiple percutaneous drainage procedures and eventual partial nephrectomy.
Arterial embolization of a bleeding gastric Dieulafoy lesion: a case report.
Mohd Rizal, M Y; Kosai, N R; Sutton, P A; Rozman, Z; Razman, J; Harunarashid, H; Das, S
2013-01-01
Dieulafoy's lesion is one of an unusual cause of upper gastrointestinal bleeding (U GIB). Endoscopic intervention has always been a preferred non-surgical method in treating UGIB including bleeding from Dieulafoy's lesion. Owing to recent advances in angiography, arterial embolization has become a popular alternative in non- variceal UGIB especially in cases with failed endoscopic treatment. However, managing bleeding Dieulafoy's with selective arterial embolization as the first line of treatment has not been exclusively practiced. We hereby, report a case of bleeding Dieulafoy lesion which had been primarily treated with arterial embolization.
Hatamaru, Keiichi; Azuma, Shunjiro; Akamatsu, Takuji; Seta, Takeshi; Urai, Shunji; Uenoyama, Yoshito; Yamashita, Yukitaka; Ono, Kazuo
2015-01-28
We report an extremely rare case of pulmonary lipiodol embolism with acute respiratory distress syndrome (ARDS) after transcatheter arterial chemoembolization (TACE) for hepatocellular carcinoma (HCC). A 77-year-old man who was diagnosed with a huge HCC was admitted for TACE. Immediately after the procedure, this patient experienced severe dyspnea. We suspected that his symptoms were associated with a pulmonary lipiodol embolism after TACE, and we began intensive treatment. However, his condition did not improve, and he died on the following day. A subsequent autopsy revealed that the cause of death was ARDS due to pulmonary lipiodol embolism. No cases have been previously reported for which an autopsy was performed to explain the most probable mechanism of pulmonary lipiodol embolism; thus, ours is the first report for such a rare case.
Patent foramen ovale and paradoxical embolization: a historical perspective.
Lippmann, H; Rafferty, T
1993-01-01
The use of transesophageal echocardiography for intraoperative management of critically ill patients allows for routine evaluation of foramen ovale patency. The high prevalence of preoperatively unrecognized flow-patency of this structure has led investigators to emphasize the potential for paradoxical embolization in any patient undergoing anesthesia. This perspective led us to research earliest documentation of paradoxical embolization through a patent foramen ovale as a historical issue with present day relevance. This report examines the 1877 text of Julius Cohnheim in which he described a fatal case of paradoxical embolization to the middle meningeal artery. The 1880 manuscript of Moritz Litten documenting paradoxical embolization to the lower extremity is also presented. Both translations, to our knowledge, represent the first such representations of both the original 1877 edition of Cohnheim's work and Litten's journal article.
Carbon Dioxide Embolism during Laparoscopic Surgery
Park, Eun Young; Kwon, Ja-Young
2012-01-01
Clinically significant carbon dioxide embolism is a rare but potentially fatal complication of anesthesia administered during laparoscopic surgery. Its most common cause is inadvertent injection of carbon dioxide into a large vein, artery or solid organ. This error usually occurs during or shortly after insufflation of carbon dioxide into the body cavity, but may result from direct intravascular insufflation of carbon dioxide during surgery. Clinical presentation of carbon dioxide embolism ranges from asymptomatic to neurologic injury, cardiovascular collapse or even death, which is dependent on the rate and volume of carbon dioxide entrapment and the patient's condition. We reviewed extensive literature regarding carbon dioxide embolism in detail and set out to describe the complication from background to treatment. We hope that the present work will improve our understanding of carbon dioxide embolism during laparoscopic surgery. PMID:22476987
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pech, Maciej, E-mail: maciej.pech@med.ovgu.de; Mohnike, Konrad; Wieners, Gero
2011-10-15
Purpose: We describe our initial clinical experience in artificial embolization with the Amplatzer Vascular Plug IV (VP IV), a further development of the Vascular Plug family already in routine use. Methods: Results from 50 embolization procedures conducted with the VP IV in 44 patients are summarized. Results: All 50 embolizations were successful, although two required the technique to be modified because of problems with jamming of the screw thread and thus with disconnection of the plug. This was associated with large branching angles. Conclusions: With experience, the VP IV can be used safely and effectively, and it expands the spectrummore » of possible embolizations in interventional radiology. Its greatest disadvantage is its relatively poor positional controllability.« less
Huang, Lingling; Awale, Reenu; Tang, Hui; Zeng, ZhiShan; Li, FuRong; Chen, Yue
2015-04-01
To summarize our experiences in the treatment of labor induction in placenta previa using uterine artery embolization. We retrospectively analyzed the clinical data of seven patients with placenta previa who underwent antepartum uterine artery embolization before vaginal delivery. After antepartum embolization, five patients with placenta previa had successful vaginal deliveries and two cases of placenta previa with accreta underwent emergency hysterectomy. Some complications were reported in this experience. The follow-up study showed that most patients resumed their normal menstruation and some of them were able to conceive. For the management of placenta previa, uterine artery embolization is a minimally invasive technique that helps to avoid cesarean section. The impact on menstruation and fertility is yet to be seen. Copyright © 2015. Published by Elsevier B.V.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Matsumoto, Keiji; Ushijima, Yasuhiro, E-mail: ushijima@radiol.med.kyushu-u.ac.jp; Tajima, Tsuyoshi
2010-02-15
A 65-year-old woman who had been diagnosed as having microscopic polyangiitis developed sudden abdominal pain and entered a state of shock. Abdominal CT showed massive hemoperitoneum, and emergent angiography revealed a ruptured splenic artery aneurysm. After direct catheterization attempts failed due to tortuous vessels and angiospasm, transcatheter arterial embolization using an n-butyl cyanoacrylate (NBCA)-lipiodol mixture was successfully performed. Fifty days later, the patient developed sudden abdominal pain again. Repeated angiography demonstrated recanalization of the splenic artery and splenic artery aneurysm. This time, the recanalized aneurysm was embolized using metallic coils with the isolation method. Physicians should keep in mind thatmore » recanalization can occur after transcatheter arterial embolization using N-butyl cyanoacrylate, which has been used as a permanent embolic agent.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vlies, Cornelis H. van der, E-mail: c.h.vandervlies@amc.n; Delden, Otto M. van, E-mail: o.m.vandelden@amc.n; Punt, Bastiaan J., E-mail: b.j.punt@asz.n
IntroductionThe spleen is the second most frequently injured organ following blunt abdominal trauma. Trends in management have changed over the years. Traditionally, laparotomy and splenectomy was the standard management. Presently, nonoperative management (NOM) of splenic injury is the most common management strategy in hemodynamically stable patients. Splenic injuries can be managed via simple observation (OBS) or with angiography and embolization (AE). Angio-embolization has shown to be a valuable alternative to observational management and has increased the success rate of nonoperative management in many series.DiagnosticsImproved imaging techniques and advances in interventional radiology have led to a better selection of patients whomore » are amenable to nonoperative management. Despite this, there is still a lot of debate about which patients are prone to NOM.Angiography and EmbolizationThe optimal patient selection is still a matter of debate and the role of CT and angio-embolization has not yet fully evolved. We discuss the role of sonography and CT features, such as contrast extravasation, pseudoaneurysms, arteriovenous fistulas, or hemoperitoneum, to determine the optimal patient selection for angiography and embolization. We also review the efficiency, technical considerations (proximal or selective embolization), logistics, and complication rates of AE for blunt traumatic splenic injuries.« less
van Delden, Otto M.; Punt, Bastiaan J.; Ponsen, Kees J.; Reekers, Jim A.; Goslings, J. Carel
2010-01-01
Introduction The spleen is the second most frequently injured organ following blunt abdominal trauma. Trends in management have changed over the years. Traditionally, laparotomy and splenectomy was the standard management. Presently, nonoperative management (NOM) of splenic injury is the most common management strategy in hemodynamically stable patients. Splenic injuries can be managed via simple observation (OBS) or with angiography and embolization (AE). Angio-embolization has shown to be a valuable alternative to observational management and has increased the success rate of nonoperative management in many series. Diagnostics Improved imaging techniques and advances in interventional radiology have led to a better selection of patients who are amenable to nonoperative management. Despite this, there is still a lot of debate about which patients are prone to NOM. Angiography and Embolization The optimal patient selection is still a matter of debate and the role of CT and angio-embolization has not yet fully evolved. We discuss the role of sonography and CT features, such as contrast extravasation, pseudoaneurysms, arteriovenous fistulas, or hemoperitoneum, to determine the optimal patient selection for angiography and embolization. We also review the efficiency, technical considerations (proximal or selective embolization), logistics, and complication rates of AE for blunt traumatic splenic injuries. PMID:20668852
Trueba, Santiago; Pouteau, Robin; Lens, Frederic; Feild, Taylor S; Isnard, Sandrine; Olson, Mark E; Delzon, Sylvain
2017-02-01
Increases in drought-induced tree mortality are being observed in tropical rain forests worldwide and are also likely to affect the geographical distribution of tropical vegetation. However, the mechanisms underlying the drought vulnerability and environmental distribution of tropical species have been little studied. We measured vulnerability to xylem embolism (P 50 ) of 13 woody species endemic to New Caledonia and with different xylem conduit morphologies. We examined the relation between P 50 , along with other leaf and xylem functional traits, and a range of habitat variables. Selected species had P 50 values ranging between -4.03 and -2.00 MPa with most species falling in a narrow range of resistance to embolism above -2.7 MPa. Embolism vulnerability was significantly correlated with elevation, mean annual temperature and percentage of species occurrences located in rain forest habitats. Xylem conduit type did not explain variation in P 50 . Commonly used functional traits such as wood density and leaf traits were not related to embolism vulnerability. Xylem embolism vulnerability stands out among other commonly used functional traits as a major driver of species environmental distribution. Drought-induced xylem embolism vulnerability behaves as a physiological trait closely associated with the habitat occupation of rain forest woody species. © 2016 John Wiley & Sons Ltd.
Choi, Jin Woo; Roh, Hong Gee; Moon, Won-Jin; Kim, Na Ra; Moon, Sung Gyu; Kang, Chung Hwan; Chun, Young Il; Kang, Hyun-Seung
2011-01-01
To evaluate the usefulness of time-resolved contrast enhanced magnetic resonance angiography (4D MRA) after stent-assisted coil embolization by comparing it with time of flight (TOF)-MRA. TOF-MRA and 4D MRA were obtained by 3T MRI in 26 patients treated with stent-assisted coil embolization (Enterprise:Neuroform = 7:19). The qualities of the MRA were rated on a graded scale of 0 to 4. We classified completeness of endovascular treatment into three categories. The degree of quality of visualization of the stented artery was compared between TOF and 4D MRA by the Wilcoxon signed rank test. We used the Mann-Whitney U test for comparing the quality of the visualization of the stented artery according to the stent type in each MRA method. The quality in terms of the visualization of the stented arteries in 4D MRA was significantly superior to that in 3D TOF-MRA, regardless of type of the stent (p < 0.001). The quality of the arteries which were stented with Neuroform was superior to that of the arteries stented with Enterprise in 3D TOF (p < 0.001) and 4D MRA (p = 0.008), respectively. 4D MRA provides a higher quality view of the stented parent arteries when compared with TOF.
Schuldt, Bernhard; Knutzen, Florian; Delzon, Sylvain; Jansen, Steven; Müller-Haubold, Hilmar; Burlett, Régis; Clough, Yann; Leuschner, Christoph
2016-04-01
Climate warming will increase the drought exposure of many forests world-wide. It is not well understood how trees adapt their hydraulic architecture to a long-term decrease in water availability. We examined 23 traits characterizing the hydraulic architecture and growth rate of branches and the dependent foliage of mature European beech (Fagus sylvatica) trees along a precipitation gradient (855-594 mm yr(-1) ) on uniform soil. A main goal was to identify traits that are associated with xylem efficiency, safety and growth. Our data demonstrate for the first time a linear increase in embolism resistance with climatic aridity (by 10%) across populations within a species. Simultaneously, vessel diameter declined by 7% and pit membrane thickness (Tm ) increased by 15%. Although specific conductivity did not change, leaf-specific conductivity declined by 40% with decreasing precipitation. Of eight plant traits commonly associated with embolism resistance, only vessel density in combination with pathway redundancy and Tm were related. We did not confirm the widely assumed trade-off between xylem safety and efficiency but obtained evidence in support of a positive relationship between hydraulic efficiency and growth. We conclude that the branch hydraulic system of beech has a distinct adaptive potential to respond to a precipitation reduction as a result of the environmental control of embolism resistance. © 2015 The Authors. New Phytologist © 2015 New Phytologist Trust.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stampfl, S.; Stampfl, U.; Rehnitz, C.
Purpose. Using a pig model: (1) to evaluate the vascular distribution pattern, including the homogeneity and completeness of the intra-arterial microsphere distribution, of 40-120-{mu}m trisacryl-gelatin microspheres (Embospheres) in acute whole-kidney embolization; (2) to evaluate the durability and biocompatibility of 40-120-{mu}m trisacryl-gelatin microspheres (Embospheres) in chronic partial kidney embolization. Methods. Twenty-two animals were divided into four groups: group 1 (n = 4) underwent total arterial renal occlusion with immediate euthanasia. Groups 2-4 had chronic superselective and partial renal embolization with increasing follow-up times: group 2 (n = 2), 1 week; group 3 (n = 7), 4 weeks; and group 4 (nmore » = 9), 14 weeks. Key endpoints in group 1 were homogeneity and completeness of acute embolizations. In groups 2-4 the key endpoints were durability of embolization and particle-related inflammation in chronic partial embolizations as assessed by quantitative angiography or histomorphometry. A numerical angiographic occlusion score (0.0 to 4.0, where 3.0 is optimal) was developed to assess and quantify the angiographic durability of superselective embolizations (groups 2-4). Results. In group 1, a relatively homogeneous distribution of the particles from segmental arteries to the precapillary level was shown by histomorphometry. Some particles reached the glomerular vas afferens (10 {mu}m diameter). In groups 2-4, a mild recanalization appeared during follow-up. The immediate average postembolization occlusion score of 3.18 {+-} 0.73 was reduced to 1.44 {+-} 0.73 (statistically significant). Microscopy revealed subtotal necrosis but no foreign body granuloma formation. The intra-arterial appearance of giant cells closely attaching to the surface of the embolic spheres inside the vessel lumen was noted. Vessel walls showed major ischemic reactions. Conclusion. Microspheres 40-120 {mu}m in diameter might achieve total occlusion of the arterial kidney vasculature when injected centrally as a result of their fairly homogeneous distribution. Segmental renal infarction occurs after chronic partial embolization despite recanalizations during follow-up. Only mild specific intra-arterial foreign body reactions were found.« less
Shi, Chaoyang; Kojima, Masahiro; Tercero, Carlos; Najdovski, Zoran; Ikeda, Seiichi; Fukuda, Toshio; Arai, Fumihito; Negoro, Makoto
2014-12-01
There are several complications associated with Stent-assisted Coil Embolization (SACE) in cerebral aneurysm treatments, due to damaging operations by surgeons and undesirable mechanical properties of stents. Therefore, it is necessary to develop an in vitro simulator that provides both training and research for evaluating the mechanical properties of stents. A new in vitro simulator for three-dimensional digital subtraction angiography was constructed, followed by aneurysm models fabricated with new materials. Next, this platform was used to provide training and to conduct photoelastic stress analysis to evaluate the SACE technique. The average interaction stress increasingly varied for the two different stents. Improvements for the Maximum-Likelihood Expectation-Maximization method were developed to reconstruct cross-sections with both thickness and stress information. The technique presented can improve a surgeon's skills and quantify the performance of stents to improve mechanical design and classification. This method can contribute to three-dimensional stress and volume variation evaluation and assess a surgeon's skills. Copyright © 2013 John Wiley & Sons, Ltd.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Little, M. W., E-mail: m.little@doctors.org.uk; Boardman, P.; Macdonald, A. C.
PurposeTo investigate the clinical impact of performing prostate artery embolization (PAE) on patients with adenomatous-dominant benign prostatic hyperplasia (AdBPH).Materials and MethodsTwelve patients from the ongoing proSTatic aRtery EmbolizAtion for the treatMent of benign prostatic hyperplasia (STREAM) trial were identified as having AdBPH; defined as two or more adenomas within the central gland of ≥1 cm diameter on multi-parametric MRI (MP-MRI). These patients were age-matched with patients from the STREAM cohort, without AdBPH. Patients were followed up with repeat MP-MRI at 3 months and 1 year. International prostate symptom score (IPSS), international index for erectile function (IIEF), and quality of life assessment from themore » IPSS and EQ-5D-5S questionnaires were recorded pre-PAE and at 6 weeks, 3 months, and 1 year.ResultsThe mean age of patients was 68 (61–76). All patients had PAE as a day-case procedure. The technical success in the cohort was 23/24 (96%). There was a significant reduction in prostate volume following embolization with a median reduction of 34% (30–55) in the AdBPH group, compared to a mean volume reduction of 22% (9–44) in the non-AdBPH group (p = 0.04). There was a significant reduction in IPSS in the AdBPH group following PAE when compared with the control group [AdBPH median IPSS 8 (3–15) vs. non-AdBPH median IPSS 13 (8–18), p = 0.01]. IPSS QOL scores significantly improved in the AdBPH group (p = 0.007). There was no deterioration in sexual function in either group post-PAE.ConclusionsThis is the first time that AdBPH has been identified as being a predictor of clinical success following PAE.« less
Effects of Perfusion on Radiofrequency Ablation in Swine Kidneys1
Chang, Isaac; Mikityansky, Igor; Wray-Cahen, Diane; Pritchard, William F.; Karanian, John W.; Wood, Bradford J.
2008-01-01
PURPOSE: To evaluate the effect of vascular occlusion on the size of radiofrequency (RF) ablation lesions and to evaluate embolization as an occlusion method. MATERIALS AND METHODS: The kidneys of six swine were surgically exposed. Fifteen RF ablation lesions were created in nine kidneys by using a 2-cm-tip single-needle ablation probe in varying conditions: Seven lesions were created with normal blood flow and eight were created with blood flow obstructed by means of vascular clamping (n = 5) or renal artery embolization (n = 3). The temperature, applied voltage, current, and impedance were recorded during RF ablation. Tissue-cooling curves acquired for 2 minutes immediately after the ablation were compared by using regression analysis. Lesions were bisected, and their maximum diameters were measured and compared by using analysis of variance. RESULTS: The mean diameter of ablation lesions created when blood flow was obstructed was 60% greater than that of lesions created when blood flow was normal (1.38 cm ± 0.05 [standard error of mean] vs 0.86 cm ± 0.07, P < .001). The two methods of flow obstruction yielded lesions of similar mean sizes: 1.40 cm ± 0.06 with vascular clamping and 1.33 cm ± 0.07 with embolization. The temperature at the probe tip when lesions were ablated with normal blood flow decreased more rapidly than did the temperature when lesions were ablated after flow obstruction (P < .001), but no significant differences in tissue-cooling curves between the two flow obstruction methods were observed. CONCLUSION: Obstruction of renal blood flow before and during RF ablation resulted in larger thermal lesions with potentially less variation in size compared with the lesions created with normal nonobstructed blood flow. Selective arterial embolization of the kidney vessels may be a useful adjunct to RF ablation of kidney tumors. PMID:15128994
Matsuo, Toshihiko; Yanai, Hiroyuki; Sugiu, Kenji; Tominaga, Susumu; Kimata, Yoshihiro
2008-01-01
We present the pathological findings at orbital exenteration in a patient with Wyburn-Mason syndrome who underwent transarterial embolization. A 31-year-old man with a 10-year history of gradual exacerbation of left exophthalmos and left cheek swelling was found to have facial and orbital arteriovenous malformations on the left side. There was no vascular malformation in the brain. The feeding arteries derived from the left internal maxillary artery, facial artery, and ophthalmic artery. He underwent several courses of transarterial embolization of the feeding arteries from the left internal maxillary artery and then from the facial artery, resulting in no reduction of the arteriovenous malformation. He finally elected to undergo ophthalmic artery embolization in the expectation of a reduction and with the understanding that he would lose sight in his left eye. Two years later, he requested lid-sparing orbital exenteration and reconstruction with cutaneous flap transfer and prosthesis for cosmetic reasons. Pathologically, orbital vascular channels of varying sizes were filled with embolizing glue and had degenerating vascular wall cells surrounded by inflammatory cell infiltration. The central retinal artery in the optic nerve was also filled with the embolizing glue, and the retina lost the ganglion cell layer and inner nuclear layer but maintained the outer nuclear layer and outer segments. Marked anastomoses and hence incomplete embolization among the feeding arteries of facial and orbital vascular malformations in Wyburn-Mason syndrome do not respond well to attempts at feeding vessel embolization, which result in unsuccessful closure of the malformation.
Tracheid diameter is the key trait determining the extent of freezing-induced embolism in conifers.
Pittermann, Jarmila; Sperry, John
2003-09-01
We tested the hypotheses that freezing-induced embolism is related to conduit diameter, and that conifers and angiosperms with conduits of equivalent diameter will exhibit similar losses of hydraulic conductivity in response to freezing. We surveyed the freeze-thaw response of conifers with a broad range of tracheid diameters by subjecting wood segments (root, stem and trunk wood) to a freeze-thaw cycle at -0.5 MPa in a centrifuge. Embolism increased as mean tracheid diameter exceeded 30 microm. Tracheids with a critical diameter greater than 43 microm were calculated to embolize in response to freezing and thawing at a xylem pressure of -0.5 MPa. To confirm that freezing-induced embolism is a function of conduit air content, we air-saturated stems of Abies lasiocarpa (Hook.) Nutt. (mean conduit diameter 13.7 +/- 0.7 microm) by pressurizing them 1 to 60 times above atmospheric pressure, prior to freezing and thawing. The air saturation method simulated the effect of increased tracheid size because the degree of super-saturation is proportional to a tracheid volume holding an equivalent amount of dissolved air at ambient pressure. Embolism increased when the dissolved air content was equivalent to a mean tracheid diameter of 30 microm at ambient air pressure. Our centrifuge and air-saturation data show that conifers are as vulnerable to freeze-thaw embolism as angiosperms with equal conduit diameter. We suggest that the hydraulic conductivity of conifer wood is maximized by increasing tracheid diameters in locations where freezing is rare. Conversely, the narrowing of tracheid diameters protects against freezing-induced embolism in cold climates.
Wexels, Fredrik; Dahl, Ola E; Pripp, Are H; Seljeflot, Ingebjørg; Borris, Lars C; Haslund, Anniken; Gudmundsen, Tor E; Lauritzen, Trine; Lassen, Michael R
2014-07-01
We have recently reported that increased levels of urine prothrombin fragment 1+2 reflected radiologically verified deep vein thrombosis. In this study we evaluated whether urine prothrombin fragment 1+2 was associated with pulmonary embolism in non-selected patients. Patients with clinical suspected pulmonary embolism were interviewed on comorbidities and medications. Urine was collected from each patient before radiological examination and snap frozen until analysed on urine prothrombin fragment 1+2 with an ELISA kit. Imaging of the pulmonary arteries were conducted with contrast enhanced computer tomography. Pulmonary embolism was diagnosed in 44/197 patients. Non-significantly higher urine prothrombin fragment 1+2 levels were found in non-selected patients with pulmonary embolism vs. those without (p=0.324). Significantly higher urine prothrombin fragment 1+2 levels were found in the pulmonary embolism positive patients without comorbidities (n=13) compared to the control group (n=28) (p=0.009). The calculated sensitivity, specificity and negative predictive value using the lowest detectable urine prothrombin fragment 1+2 level was 82%, 34% and 87%, respectively. There was no significant urine prothrombin fragment 1+2 level difference in patients with and without pulmonary embolism. In non-comorbide pulmonary embolism positive patients the urine prothrombin fragment 1+2 levels were significantly higher compared to the control group. The negative predictive value found in this study indicates that uF1+2 has the potential to identify patients with a low risk of PE. Copyright © 2014 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ohta, Shinichi, E-mail: junryuhei@yahoo.co.jp; Nitta, Norihisa, E-mail: r34nitta@belle.shiga-med.ac.jp; Watanabe, Shobu, E-mail: swat@belle.shiga-med.ac.jp
2013-08-01
PurposeTo evaluate the embolic effect and degradability of gelatin microspheres (GMS) using various degrees of cross-linkage and particle sizes in rabbit renal artery embolization.MethodsFour types of GMS were used, as follows: 2 types of cross-linkage and 2 types of particle size. Twenty-four rabbits (6 in each group) were used for the renal artery embolization. Renal angiography was performed before and after embolization of right renal artery. Follow-up renal angiography was performed 2 days (n = 2), 5 days (n = 2), and 15 days (n = 2) after embolization in each group, and then kidneys were removed for histopathological evaluation.more » Vascular areas of the angiography were measured by Image J software, and the reperfusion rate was calculated. In renal specimens, residual GMS were checked and the degree of degradation was classified according to a 4-point scale.ResultsThe mean amounts of large- and small-particle-size GMS injected were 15.0 and 34.3 mg, respectively. Tissue necrosis was confirmed in each group; however, no difference was observed among groups. Renal reperfusion was observed more with small GMS than with large GMS. Renal reperfusion was also observed more with low cross-linked GMS than with high cross-linked GMS. In histopathological specimens, large GMS were confirmed in lobar artery, and small GMS were confirmed in lobular artery. Low cross-linked GMS completely degraded 15 days after embolization. In contrast, high cross-linked GMS were persistent 15 days after embolization.ConclusionDegree of cross-linkage and particle size affected degradability and reperfusion.« less
Mohammadi, Abdolreza Rashidi; Chen, Keqin; Ali, Mohamed Sultan Mohamed; Takahata, Kenichi
2011-12-15
The rupture of a cerebral aneurysm is the most common cause of subarachnoid hemorrhage. Endovascular embolization of the aneurysms by implantation of Guglielmi detachable coils (GDC) has become a major treatment approach in the prevention of a rupture. Implantation of the coils induces formation of tissues over the coils, embolizing the aneurysm. However, blood entry into the coiled aneurysm often occurs due to failures in the embolization process. Current diagnostic methods used for aneurysms, such as X-ray angiography and computer tomography, are ineffective for continuous monitoring of the disease and require extremely expensive equipment. Here we present a novel technique for wireless monitoring of cerebral aneurysms using implanted embolization coils as radiofrequency resonant sensors that detect the blood entry. The experiments show that commonly used embolization coils could be utilized as electrical inductors or antennas. As the blood flows into a coil-implanted aneurysm, parasitic capacitance of the coil is modified because of the difference in permittivity between the blood and the tissues grown around the coil, resulting in a change in the coil's resonant frequency. The resonances of platinum GDC-like coils embedded in aneurysm models are detected to show average responses of 224-819 MHz/ml to saline injected into the models. This preliminary demonstration indicates a new possibility in the use of implanted GDC as a wireless sensor for embolization failures, the first step toward realizing long-term, noninvasive, and cost-effective remote monitoring of cerebral aneurysms treated with coil embolization. Copyright © 2011 Elsevier B.V. All rights reserved.
Kim, Byungjun; Jeon, Pyoung; Kim, Keonha; Kim, Sungtae; Kim, Hyungjin; Byun, Hong Sik; Jo, Kyung-Il
2016-04-01
Endovascular treatment using Onyx has been increasingly used to treat intracranial dural arteriovenous fistulas (DAVFs). This study evaluated predictive factors for favorable treatment outcome in patients with intracranial noncavernous DAVFs treated by transarterial Onyx embolization. Between August 2008 and August 2014, 55 patients who underwent transarterial Onyx embolization for noncavernous DAVFs were retrospectively reviewed. Patients' demographic, clinical, and procedural data were analyzed to find statistically significant predictive factors for favorable treatment outcomes after Onyx embolization. Fistulas were classified angiographically according to the relationship between fistulas and dural venous sinuses and the presence of leptomeningeal venous reflux. Sixty-eight Onyx embolizations were performed in 55 patients. Immediate angiographic cure was achieved in 28 patients, and 14 of 27 patients with residual shunts showed progressive occlusion at follow-up imaging studies. Therefore, the overall favorable treatment outcome was 76.4% (42/55). The remaining 13 patients (23.6%) showed persistent residual shunts, and 3 (5.5%) of them showed aggravation of residual lesion on follow-up studies. Of 25 patients with non-sinus fistulas, 23 patients (92%) showed favorable treatment outcomes, and 19 of 30 patients (63.3%) with sinus fistulas showed favorable outcomes. Among the evaluated variables, non-sinus DAVFs was a statistically significant predictive factor for favorable response to transarterial Onyx embolization (P < 0.05). Transarterial Onyx embolization is a highly effective treatment method for non-sinus DAVFs. Careful consideration of angiographic features and multimodal embolization strategies are required for treatment of sinus DAVFs. Copyright © 2016 Elsevier Inc. All rights reserved.