Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 1 2010-10-01 2010-10-01 false Backup power. 12.2 Section 12.2 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL REDUNDANCY OF COMMUNICATIONS SYSTEMS § 12.2 Backup power..., must have an emergency backup power source (e.g., batteries, generators, fuel cells) for all assets...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
This report documents the results of the Defense Programs (DP) Augmented Evaluation Team (AET) review of emergency and backup power supplies (i.e., generator, uninterruptible power supply, and battery systems) at DP facilities. The review was conducted in response to concerns expressed by former Secretary of Energy James D. Watkins over the number of incidents where backup power sources failed to provide electrical power during tests or actual demands. The AET conducted a series of on-site reviews for the purpose of understanding the design, operation, maintenance, and safety significance of emergency and backup power (E&BP) supplies. The AET found that themore » quality of programs related to maintenance of backup power systems varies greatly among the sites visited, and often among facilities at the same site. No major safety issues were identified. However, there are areas where the AET believes the reliability of emergency and backup power systems can and should be improved. Recommendations for improving the performance of E&BP systems are provided in this report. The report also discusses progress made by Management and Operating (M&O) contractors to improve the reliability of backup sources used in safety significant applications. One area that requires further attention is the analysis and understanding of the safety implications of backup power equipment. This understanding is needed for proper graded-approach implementation of Department of Energy (DOE) Orders, and to help ensure that equipment important to the safety of DOE workers, the public, and the environment is identified, classified, recognized, and treated as such by designers, users, and maintainers. Another area considered important for improving E&BP system performance is the assignment of overall ownership responsibility and authority for ensuring that E&BP equipment performs adequately and that reliability and availability are maintained at acceptable levels.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ma, Zhiwen; Eichman, Joshua D; Kurtz, Jennifer M
This paper presents the feasibility and economics of using fuel cell backup power systems in telecommunication cell towers to provide grid services (e.g., ancillary services, demand response). The fuel cells are able to provide power for the cell tower during emergency conditions. This study evaluates the strategic integration of clean, efficient, and reliable fuel cell systems with the grid for improved economic benefits. The backup systems have potential as enhanced capability through information exchanges with the power grid to add value as grid services that depend on location and time. The economic analysis has been focused on the potential revenuemore » for distributed telecommunications fuel cell backup units to provide value-added power supply. This paper shows case studies on current fuel cell backup power locations and regional grid service programs. The grid service benefits and system configurations for different operation modes provide opportunities for expanding backup fuel cell applications responsive to grid needs.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
BUSCH, M.S.
2000-02-02
NFPA 101, section 5-9 mandates that, where required by building classification, all designated emergency egress routes be provided with adequate emergency lighting in the event of a normal lighting outage. Emergency lighting is to be arranged so that egress routes are illuminated to an average of 1.0 footcandle with a minimum at any point of 0.1 footcandle, as measured at floor level. These levels are permitted to drop to 60% of their original value over the required 90 minute emergency lighting duration after a power outage. The Plutonium Finishing Plant (PFP) has two designations for battery powered egress lights ''Emergencymore » Lights'' are those battery powered lights required by NFPA 101 to provide lighting along officially designated egress routes in those buildings meeting the correct occupancy requirements. Emergency Lights are maintained on a monthly basis by procedure ZSR-12N-001. ''Backup Lights'' are battery powered lights not required by NFPA, but installed in areas where additional light may be needed. The Backup Light locations were identified by PFP Safety and Engineering based on several factors. (1) General occupancy and type of work in the area. Areas occupied briefly during a shiftly surveillance do not require backup lighting while a room occupied fairly frequently or for significant lengths of time will need one or two Backup lights to provide general illumination of the egress points. (2) Complexity of the egress routes. Office spaces with a standard hallway/room configuration will not require Backup Lights while a large room with several subdivisions or irregularly placed rooms, doors, and equipment will require Backup Lights to make egress safer. (3) Reasonable balance between the safety benefits of additional lighting and the man-hours/exposure required for periodic light maintenance. In some plant areas such as building 236-Z, the additional maintenance time and risk of contamination do not warrant having Backup Lights installed in all rooms. Sufficient light for egress is provided by existing lights located in the hallways.« less
Flight control systems development of highly maneuverable aircraft technology /HiMAT/ vehicle
NASA Technical Reports Server (NTRS)
Petersen, K. L.
1979-01-01
The highly maneuverable aircraft technology (HiMAT) program was conceived to demonstrate advanced technology concepts through scaled-aircraft flight tests using a remotely piloted technique. Closed-loop primary flight control is performed from a ground-based cockpit, utilizing a digital computer and up/down telemetry links. A backup flight control system for emergency operation resides in an onboard computer. The onboard systems are designed to provide fail-operational capabilities and utilize two microcomputers, dual uplink receiver/decoders, and redundant hydraulic actuation and power systems. This paper discusses the design and validation of the primary and backup digital flight control systems as well as the unique pilot and specialized systems interfaces.
NASA Technical Reports Server (NTRS)
Burken, John J.; Burcham, Frank W., Jr.; Maine, Trindel A.; Feather, John; Goldthorpe, Steven; Kahler, Jeffrey A.
1996-01-01
A large, civilian, multi-engine transport MD-11 airplane control system was recently modified to perform as an emergency backup controller using engine thrust only. The emergency backup system, referred to as the propulsion-controlled aircraft (PCA) system, would be used if a major primary flight control system fails. To allow for longitudinal and lateral-directional control, the PCA system requires at least two engines and is implemented through software modifications. A flight-test program was conducted to evaluate the PCA system high-altitude flying characteristics and to demonstrate its capacity to perform safe landings. The cruise flight conditions, several low approaches and one landing without any aerodynamic flight control surface movement, were demonstrated. This paper presents results that show satisfactory performance of the PCA system in the longitudinal axis. Test results indicate that the lateral-directional axis of the system performed well at high attitude but was sluggish and prone to thermal upsets during landing approaches. Flight-test experiences and test techniques are also discussed with emphasis on the lateral-directional axis because of the difficulties encountered in flight test.
Roadside-based communication system and method
NASA Technical Reports Server (NTRS)
Bachelder, Aaron D. (Inventor)
2007-01-01
A roadside-based communication system providing backup communication between emergency mobile units and emergency command centers. In the event of failure of a primary communication, the mobile units transmit wireless messages to nearby roadside controllers that may take the form of intersection controllers. The intersection controllers receive the wireless messages, convert the messages into standard digital streams, and transmit the digital streams along a citywide network to a destination intersection or command center.
A SWOT Analysis of the Various Backup Scenarios Used in Electronic Medical Record Systems.
Seo, Hwa Jeong; Kim, Hye Hyeon; Kim, Ju Han
2011-09-01
Electronic medical records (EMRs) are increasingly being used by health care services. Currently, if an EMR shutdown occurs, even for a moment, patient safety and care can be seriously impacted. Our goal was to determine the methodology needed to develop an effective and reliable EMR backup system. Our "independent backup system by medical organizations" paradigm implies that individual medical organizations develop their own EMR backup systems within their organizations. A "personal independent backup system" is defined as an individual privately managing his/her own medical records, whereas in a "central backup system by the government" the government controls all the data. A "central backup system by private enterprises" implies that individual companies retain control over their own data. A "cooperative backup system among medical organizations" refers to a networked system established through mutual agreement. The "backup system based on mutual trust between an individual and an organization" means that the medical information backup system at the organizational level is established through mutual trust. Through the use of SWOT analysis it can be shown that cooperative backup among medical organizations is possible to be established through a network composed of various medical agencies and that it can be managed systematically. An owner of medical information only grants data access to the specific person who gave the authorization for backup based on the mutual trust between an individual and an organization. By employing SWOT analysis, we concluded that a linkage among medical organizations or between an individual and an organization can provide an efficient backup system.
A SWOT Analysis of the Various Backup Scenarios Used in Electronic Medical Record Systems
Seo, Hwa Jeong; Kim, Hye Hyeon
2011-01-01
Objectives Electronic medical records (EMRs) are increasingly being used by health care services. Currently, if an EMR shutdown occurs, even for a moment, patient safety and care can be seriously impacted. Our goal was to determine the methodology needed to develop an effective and reliable EMR backup system. Methods Our "independent backup system by medical organizations" paradigm implies that individual medical organizations develop their own EMR backup systems within their organizations. A "personal independent backup system" is defined as an individual privately managing his/her own medical records, whereas in a "central backup system by the government" the government controls all the data. A "central backup system by private enterprises" implies that individual companies retain control over their own data. A "cooperative backup system among medical organizations" refers to a networked system established through mutual agreement. The "backup system based on mutual trust between an individual and an organization" means that the medical information backup system at the organizational level is established through mutual trust. Results Through the use of SWOT analysis it can be shown that cooperative backup among medical organizations is possible to be established through a network composed of various medical agencies and that it can be managed systematically. An owner of medical information only grants data access to the specific person who gave the authorization for backup based on the mutual trust between an individual and an organization. Conclusions By employing SWOT analysis, we concluded that a linkage among medical organizations or between an individual and an organization can provide an efficient backup system. PMID:22084811
Khandelwal, Nita; Khorsand, Sarah; Mitchell, Steven H; Joffe, Aaron M
2016-04-01
Based on the data from elective surgical patients, positioning patients in a back-up head-elevated position for preoxygenation and tracheal intubation can improve patient safety. However, data specific to the emergent setting are lacking. We hypothesized that back-up head-elevated positioning would be associated with a decrease in complications related to tracheal intubation in the emergency room environment. This retrospective study was approved by the University of Washington Human Subjects Division (Seattle, WA). Eligible patients included all adults undergoing emergent tracheal intubation outside of the operating room by the anesthesiology-based airway service at 2 university-affiliated teaching hospitals. All intubations were through direct laryngoscopy for an indication other than full cardiopulmonary arrest. Patient characteristics and details of the intubation procedure were derived from the medical record. The primary study endpoint was the occurrence of a composite of any intubation-related complication: difficult intubation, hypoxemia, esophageal intubation, or pulmonary aspiration. Multivariable logistic regression was used to estimate the odds of the primary endpoint in the supine versus back-up head-elevated positions with adjustment for a priori-defined potential confounders (body mass index and a difficult intubation prediction score [Mallampati, obstructive sleep Apnea, Cervical mobility, mouth Opening, Coma, severe Hypoxemia, and intubation by a non-Anesthesiologist score]). Five hundred twenty-eight patients were analyzed. Overall, at least 1 intubation-related complication occurred in 76 of 336 (22.6%) patients managed in the supine position compared with 18 of 192 (9.3%) patients managed in the back-up head-elevated position. After adjusting for body mass index and the Mallampati, obstructive sleep Apnea, Cervical mobility, mouth Opening, Coma, severe Hypoxemia, and intubation by a non-Anesthesiologist score, the odds of encountering the primary endpoint during an emergency tracheal intubation in a back-up head-elevated position was 0.47 (95% confidence interval, 0.26-0.83; P = 0.01). Placing patients in a back-up head-elevated position, compared with supine position, during emergency tracheal intubation was associated with a reduced odds of airway-related complications.
DOMe: A deduplication optimization method for the NewSQL database backups
Wang, Longxiang; Zhu, Zhengdong; Zhang, Xingjun; Wang, Yinfeng
2017-01-01
Reducing duplicated data of database backups is an important application scenario for data deduplication technology. NewSQL is an emerging database system and is now being used more and more widely. NewSQL systems need to improve data reliability by periodically backing up in-memory data, resulting in a lot of duplicated data. The traditional deduplication method is not optimized for the NewSQL server system and cannot take full advantage of hardware resources to optimize deduplication performance. A recent research pointed out that the future NewSQL server will have thousands of CPU cores, large DRAM and huge NVRAM. Therefore, how to utilize these hardware resources to optimize the performance of data deduplication is an important issue. To solve this problem, we propose a deduplication optimization method (DOMe) for NewSQL system backup. To take advantage of the large number of CPU cores in the NewSQL server to optimize deduplication performance, DOMe parallelizes the deduplication method based on the fork-join framework. The fingerprint index, which is the key data structure in the deduplication process, is implemented as pure in-memory hash table, which makes full use of the large DRAM in NewSQL system, eliminating the performance bottleneck problem of fingerprint index existing in traditional deduplication method. The H-store is used as a typical NewSQL database system to implement DOMe method. DOMe is experimentally analyzed by two representative backup data. The experimental results show that: 1) DOMe can reduce the duplicated NewSQL backup data. 2) DOMe significantly improves deduplication performance by parallelizing CDC algorithms. In the case of the theoretical speedup ratio of the server is 20.8, the speedup ratio of DOMe can achieve up to 18; 3) DOMe improved the deduplication throughput by 1.5 times through the pure in-memory index optimization method. PMID:29049307
Singh, Param Puneet; Singh, Mukesh; Bedi, Updesh Singh; Adigopula, Sasikanth; Singh, Sarabjeet; Kodumuri, Vamsi; Molnar, Janos; Ahmed, Aziz; Arora, Rohit; Khosla, Sandeep
2011-01-01
Despite major advances in percutaneous coronary intervention (PCI) techniques, the current guidelines recommend against elective PCI at hospitals without on-site cardiac surgery backup. Nonetheless, an increasing number of hospitals without on-site cardiac surgery in the United States have developed programs for elective PCI. Studies evaluating outcome in this setting have yielded mixed results, leaving the question unanswered. Hence, a meta-analysis comparing outcomes of nonemergent PCI in hospitals with and without on-site surgical backup was performed. A systematic review of literature identified four studies involving 6817 patients. Three clinical end points were extracted from each study and included in-hospital death, myocardial infarction, and the need for emergency coronary artery bypass grafting. The studies were homogenous for each outcome studied. Therefore, the combined relative risks (RRs) across all the studies and the 95% confidence intervals (CIs) were computed using the Mantel-Haenszel fixed-effect model. A two-sided alpha error less than 0.05 was considered to be statistically significant. Compared with facilities with on-site surgical backup, the risk of in-hospital death (RR, 2.7; CI, 0.6-12.9; P = 0.18), nonfatal myocardial infarction (RR, 1.3; CI, 0.7- 2.2; P = 0.29), and need of emergent coronary artery bypass grafting (RR, 0.46; CI, 0.06- 3.1; P = 0.43) was similar in those lacking on-site surgical backup. The present meta-analysis suggests that there is no difference in the outcome with regard to risk of nonfatal myocardial infarction, need for emergency coronary artery bypass grafting, and the risk of death in patients undergoing elective PCI in hospitals with and without on-site cardiac surgery backup.
Code of Federal Regulations, 2011 CFR
2011-10-01
... exchange carriers, including incumbent local exchange carriers and competitive local exchange carriers..., must have an emergency backup power source (e.g., batteries, generators, fuel cells) for all assets... or local law; (2) Risk to safety of life or health; or (3) Private legal obligation or agreement. (c...
Code of Federal Regulations, 2010 CFR
2010-10-01
... tool or other implement. (c) The status of each powered, exterior side door in a passenger car shall be displayed to the crew in the operating cab. If door interlocks are used, the sensors used to detect train... car shall be connected to an emergency back-up power system. (e) A railroad may protect a manual...
Code of Federal Regulations, 2011 CFR
2011-10-01
... tool or other implement. (c) The status of each powered, exterior side door in a passenger car shall be displayed to the crew in the operating cab. If door interlocks are used, the sensors used to detect train... car shall be connected to an emergency back-up power system. (e) A railroad may protect a manual...
Mechanization of and experience with a triplex fly-by-wire backup control system
NASA Technical Reports Server (NTRS)
Lock, W. P.; Petersen, W. R.; Whitman, G. B.
1976-01-01
A redundant three axis analog control system was designed and developed to back up a digital fly by wire control system for an F-8C airplane. The mechanization and operational experience with the backup control system, the problems involved in synchronizing it with the primary system, and the reliability of the system are discussed. The backup control system was dissimilar to the primary system, and it provided satisfactory handling through the flight envelope evaluated. Limited flight tests of a variety of control tasks showed that control was also satisfactory when the backup control system was controlled by a minimum displacement (force) side stick. The operational reliability of the F-8 digital fly by wire control system was satisfactory, with no unintentional downmodes to the backup control system in flight. The ground and flight reliability of the system's components is discussed.
The Recovery of a Clinical Database Management System after Destruction by Fire *
Covvey, H.D.; McAlister, N.H.; Greene, J.; Wigle, E.D.
1981-01-01
In August 1980 a fire in the Cardiovascular Unit at Toronto General Hospital severely damaged the physical plant and rendered all on-site equipment unrecoverable. Among the hardware items in the fire was the computer which supports our cardiovascular database system. Within hours after the fire it was determined that the computer was no longer serviceable. Beyond off-site back-up tapes, there was the possibility that recent records on the computer had suffered a similar fate. Immediate procedures were instituted to obtain a replacement computer system and to clean media to permit data recovery. Within 2 months a partial system was supporting all users, and all data was recovered and being used. The destructive potential of a fire is rarely seriously considered relative to computer equipment in our clinical environments. Full-replacement value insurance; an excellent equipment supplier with the capacity to respond to an emergency; backup and recovery procedures with off-site storage; and dedicated staff are key hedges against disaster.
Mechanization of and experience with a triplex fly-by-wire backup control system
NASA Technical Reports Server (NTRS)
Lock, W. P.; Petersen, W. R.; Whitman, G. B.
1975-01-01
A redundant three-axis analog control system was designed and developed to back up a digital fly-by-wire control system for an F-8C airplane. Forty-two flights, involving 58 hours of flight time, were flown by six pilots. The mechanization and operational experience with the backup control system, the problems involved in synchronizing it with the primary system, and the reliability of the system are discussed. The backup control system was dissimilar to the primary system, and it provided satisfactory handling through the flight envelope evaluated. Limited flight tests of a variety of control tasks showed that control was also satisfactory when the backup control system was controlled by a minimum-displacement (force) side stick. The operational reliability of the F-8 digital fly-by-wire control system was satisfactory, with no unintentional downmodes to the backup control system in flight. The ground and flight reliability of the system's components is discussed.
30 CFR 75.1101-9 - Back-up water system.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Back-up water system. 75.1101-9 Section 75.1101-9 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection § 75.1101-9 Back-up water system...
30 CFR 75.1101-9 - Back-up water system.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Back-up water system. 75.1101-9 Section 75.1101-9 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection § 75.1101-9 Back-up water system...
30 CFR 75.1101-9 - Back-up water system.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Back-up water system. 75.1101-9 Section 75.1101-9 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection § 75.1101-9 Back-up water system...
30 CFR 75.1101-9 - Back-up water system.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Back-up water system. 75.1101-9 Section 75.1101-9 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection § 75.1101-9 Back-up water system...
30 CFR 75.1101-9 - Back-up water system.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Back-up water system. 75.1101-9 Section 75.1101-9 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection § 75.1101-9 Back-up water system...
STS-47 backup payload specialists participate in JSC WETF bailout exercise
NASA Technical Reports Server (NTRS)
1992-01-01
STS-47 Endeavour, Orbiter Vehicle (OV) 105, backup payload specialists (left to right) Chiaki Naito-Mukai, Takao Doi, and Stan Koszelak, wearing launch and entry suits, sit on the poolside in JSC's Weightless Environment Training Facility (WETF) Bldg 29. These alternates are waiting to participate launch emergency egress (bailout) exercises. The training is conducted in the WETF pool to simulate a water landing.
Disaster recovery plan for HANDI 2000 business management system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Adams, D.E.
The BMS production implementation will be complete by October 1, 1998 and the server environment will be comprised of two types of platforms. The PassPort Supply and the PeopleSoft Financials will reside on LNIX servers and the PeopleSoft Human Resources and Payroll will reside on Microsoft NT servers. Because of the wide scope and the requirements of the COTS products to run in various environments backup and recovery responsibilities are divided between two groups in Technical Operations. The Central Computer Systems Management group provides support for the LTNIX/NT Backup Data Center, and the Network Infrastructure Systems group provides support formore » the NT Application Server Backup outside the Data Center. The disaster recovery process is dependent on a good backup and recovery process. Information and integrated system data for determining the disaster recovery process is identified from the Fluor Daniel Hanford (FDH) Risk Assessment Plan, Contingency Plan, and Backup and Recovery Plan, and Backup Form for HANDI 2000 BMS.« less
Rates for backup service under PURPA when the supplying utility has excess generating capacity
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
Under PURPA, cogenerators are entitled to receive backup service. It is often said that tariffs for backup service should reflect the low probability that an unscheduled outage will occur during system peak. This memorandum concludes that probabilistic analysis of contribution to coincident peak demand is not relevant under PURPA during periods in which a utility system is experiencing generating capacity surpluses, and that in such situations, backup rates should be designed so that should the customer insist on installing a cogeneration system, that the customer's contribution to fixed costs remains constant. The reason for this is to assure that prospectivemore » cogenerators receive appropriate pricing signals in their assessment of proposed cogeneration projects, and should they decide to install cogeneration facilities requiring backup service, to hold the remaining customers on the system harmless.« less
STS-52 backup Payload Specialist Tryggvason during JSC bailout exercises
NASA Technical Reports Server (NTRS)
1992-01-01
STS-52 Columbia, Orbiter Vehicle (OV) 102, backup Payload Specialist Bjarni V. Tryggvason, wearing launch and entry suit (LES), checks his launch and entry helmet (LEH) fitting prior to participating in emergency egress (bailout) training exercises in JSC's Weightless Environment Training Facility (WETF) Bldg 29. The WETF's 25-ft deep pool will serve as the ocean during this water landing simulation. Tryggvason represents the Canadian Space Agency (CSA).
Operating and Managing a Backup Control Center
NASA Technical Reports Server (NTRS)
Marsh, Angela L.; Pirani, Joseph L.; Bornas, Nicholas
2010-01-01
Due to the criticality of continuous mission operations, some control centers must plan for alternate locations in the event an emergency shuts down the primary control center. Johnson Space Center (JSC) in Houston, Texas is the Mission Control Center (MCC) for the International Space Station (ISS). Due to Houston s proximity to the Gulf of Mexico, JSC is prone to threats from hurricanes which could cause flooding, wind damage, and electrical outages to the buildings supporting the MCC. Marshall Space Flight Center (MSFC) has the capability to be the Backup Control Center for the ISS if the situation is needed. While the MSFC Huntsville Operations Support Center (HOSC) does house the BCC, the prime customer and operator of the ISS is still the JSC flight operations team. To satisfy the customer and maintain continuous mission operations, the BCC has critical infrastructure that hosts ISS ground systems and flight operations equipment that mirrors the prime mission control facility. However, a complete duplicate of Mission Control Center in another remote location is very expensive to recreate. The HOSC has infrastructure and services that MCC utilized for its backup control center to reduce the costs of a somewhat redundant service. While labor talents are equivalent, experiences are not. Certain operations are maintained in a redundant mode, while others are simply maintained as single string with adequate sparing levels of equipment. Personnel at the BCC facility must be trained and certified to an adequate level on primary MCC systems. Negotiations with the customer were done to match requirements with existing capabilities, and to prioritize resources for appropriate level of service. Because some of these systems are shared, an activation of the backup control center will cause a suspension of scheduled HOSC activities that may share resources needed by the BCC. For example, the MCC is monitoring a hurricane in the Gulf of Mexico. As the threat to MCC increases, HOSC must begin a phased activation of the BCC, while working resource conflicts with normal HOSC activities. In a long duration outage to the MCC, this could cause serious impacts to the BCC host facility s primary mission support activities. This management of a BCC is worked based on customer expectations and negotiations done before emergencies occur. I.
International Space Station Electrodynamic Tether Reboost Study
NASA Technical Reports Server (NTRS)
Johnson, L.; Herrmann, M.
1998-01-01
The International Space Station (ISS) will require periodic reboost due to atmospheric aerodynamic drag. This is nominally achieved through the use of thruster firings by the attached Progress M spacecraft. Many Progress flights to the ISS are required annually. Electrodynamic tethers provide an attractive alternative in that they can provide periodic reboost or continuous drag cancellation using no consumables, propellant, nor conventional propulsion elements. The system could also serve as an emergency backup reboost system used only in the event resupply and reboost are delayed for some reason.
Design and Implementation of Real-Time Off-Grid Detection Tool Based on FNET/GridEye
DOE Office of Scientific and Technical Information (OSTI.GOV)
Guo, Jiahui; Zhang, Ye; Liu, Yilu
2014-01-01
Real-time situational awareness tools are of critical importance to power system operators, especially during emergencies. The availability of electric power has become a linchpin of most post disaster response efforts as it is the primary dependency for public and private sector services, as well as individuals. Knowledge of the scope and extent of facilities impacted, as well as the duration of their dependence on backup power, enables emergency response officials to plan for contingencies and provide better overall response. Based on real-time data acquired by Frequency Disturbance Recorders (FDRs) deployed in the North American power grid, a real-time detection methodmore » is proposed. This method monitors critical electrical loads and detects the transition of these loads from an on-grid state, where the loads are fed by the power grid to an off-grid state, where the loads are fed by an Uninterrupted Power Supply (UPS) or a backup generation system. The details of the proposed detection algorithm are presented, and some case studies and off-grid detection scenarios are also provided to verify the effectiveness and robustness. Meanwhile, the algorithm has already been implemented based on the Grid Solutions Framework (GSF) and has effectively detected several off-grid situations.« less
A low cost LST pointing control system
NASA Technical Reports Server (NTRS)
Glaese, J. R.; Kennel, H. F.; Nurre, G. S.; Seltzer, S. M.; Shelton, H. L.
1975-01-01
Vigorous efforts to reduce costs, coupled with changes in LST guidelines, took place in the Fall of 1974. These events made a new design of the LST and its Pointing and Attitude Control System possible. The major design changes are summarized as: an annular Support Systems Module; removal of image motion compensation; reaction wheels instead of CMG's; a magnetic torquer system to also perform the emergency and backup functions, eliminating the previously required mass expulsion system. Preliminary analysis indicates the Low Cost LST concept can meet the newly defined requirements and results in a significantly reduced development cost.
Ma, Jiaqi; Zhou, Maigeng; Li, Yanfei; Guo, Yan; Su, Xuemei; Qi, Xiaopeng; Ge, Hui
2009-05-01
To describe the design and application of an emergency response mobile phone-based information system for infectious disease reporting. Software engineering and business modeling were used to design and develop the emergency response mobile phone-based information system for infectious disease reporting. Seven days after the initiation of the reporting system, the reporting rate in the earthquake zone reached the level of the same period in 2007, using the mobile phone-based information system. Surveillance of the weekly report on morbidity in the earthquake zone after the initiation of the mobile phone reporting system showed the same trend as the previous three years. The emergency response mobile phone-based information system for infectious disease reporting was an effective solution to transmit urgently needed reports and manage communicable disease surveillance information. This assured the consistency of disease surveillance and facilitated sensitive, accurate, and timely disease surveillance. It is an important backup for the internet-based direct reporting system for communicable disease. © 2009 Blackwell Publishing Asia Pty Ltd and Chinese Cochrane Center, West China Hospital of Sichuan University.
Practical, redundant, failure-tolerant, self-reconfiguring embedded system architecture
Klarer, Paul R.; Hayward, David R.; Amai, Wendy A.
2006-10-03
This invention relates to system architectures, specifically failure-tolerant and self-reconfiguring embedded system architectures. The invention provides both a method and architecture for redundancy. There can be redundancy in both software and hardware for multiple levels of redundancy. The invention provides a self-reconfiguring architecture for activating redundant modules whenever other modules fail. The architecture comprises: a communication backbone connected to two or more processors and software modules running on each of the processors. Each software module runs on one processor and resides on one or more of the other processors to be available as a backup module in the event of failure. Each module and backup module reports its status over the communication backbone. If a primary module does not report, its backup module takes over its function. If the primary module becomes available again, the backup module returns to its backup status.
Fault tree applications within the safety program of Idaho Nuclear Corporation
NASA Technical Reports Server (NTRS)
Vesely, W. E.
1971-01-01
Computerized fault tree analyses are used to obtain both qualitative and quantitative information about the safety and reliability of an electrical control system that shuts the reactor down when certain safety criteria are exceeded, in the design of a nuclear plant protection system, and in an investigation of a backup emergency system for reactor shutdown. The fault tree yields the modes by which the system failure or accident will occur, the most critical failure or accident causing areas, detailed failure probabilities, and the response of safety or reliability to design modifications and maintenance schemes.
Utilizing data grid architecture for the backup and recovery of clinical image data.
Liu, Brent J; Zhou, M Z; Documet, J
2005-01-01
Grid Computing represents the latest and most exciting technology to evolve from the familiar realm of parallel, peer-to-peer and client-server models. However, there has been limited investigation into the impact of this emerging technology in medical imaging and informatics. In particular, PACS technology, an established clinical image repository system, while having matured significantly during the past ten years, still remains weak in the area of clinical image data backup. Current solutions are expensive or time consuming and the technology is far from foolproof. Many large-scale PACS archive systems still encounter downtime for hours or days, which has the critical effect of crippling daily clinical operations. In this paper, a review of current backup solutions will be presented along with a brief introduction to grid technology. Finally, research and development utilizing the grid architecture for the recovery of clinical image data, in particular, PACS image data, will be presented. The focus of this paper is centered on applying a grid computing architecture to a DICOM environment since DICOM has become the standard for clinical image data and PACS utilizes this standard. A federation of PACS can be created allowing a failed PACS archive to recover its image data from others in the federation in a seamless fashion. The design reflects the five-layer architecture of grid computing: Fabric, Resource, Connectivity, Collective, and Application Layers. The testbed Data Grid is composed of one research laboratory and two clinical sites. The Globus 3.0 Toolkit (Co-developed by the Argonne National Laboratory and Information Sciences Institute, USC) for developing the core and user level middleware is utilized to achieve grid connectivity. The successful implementation and evaluation of utilizing data grid architecture for clinical PACS data backup and recovery will provide an understanding of the methodology for using Data Grid in clinical image data backup for PACS, as well as establishment of benchmarks for performance from future grid technology improvements. In addition, the testbed can serve as a road map for expanded research into large enterprise and federation level data grids to guarantee CA (Continuous Availability, 99.999% up time) in a variety of medical data archiving, retrieval, and distribution scenarios.
A priority dispatch system for emergency medical services.
Slovis, C M; Carruth, T B; Seitz, W J; Thomas, C M; Elsea, W R
1985-11-01
A decision tree priority dispatch system for emergency medical services (EMS) was developed and implemented in Atlanta and Fulton County, Georgia. The dispatch system shortened the average response time from 14.2 minutes to 10.4 minutes for the 30% of patients deemed most urgent (P less than or equal to .05); resulted in a significant increase in the use of advanced life support units for this group (P less than or equal to .02); decreased the number of calls that required a backup ambulance service; and significantly increased conformity to national EMS response time standards for critically ill and injured patients (P less than or equal to .0009). Due to dispatch error, 0.3% of calls were dispatched as least severe but subsequently were found to be most urgent.
Reliability considerations of a fuel cell backup power system for telecom applications
NASA Astrophysics Data System (ADS)
Serincan, Mustafa Fazil
2016-03-01
A commercial fuel cell backup power unit is tested in real life operating conditions at a base station of a Turkish telecom operator. The fuel cell system responds to 256 of 260 electric power outages successfully, providing the required power to the base station. Reliability of the fuel cell backup power unit is found to be 98.5% at the system level. On the other hand, a qualitative reliability analysis at the component level is carried out. Implications of the power management algorithm on reliability is discussed. Moreover, integration of the backup power unit to the base station ecosystem is reviewed in the context of reliability. Impact of inverter design on the stability of the output power is outlined. Significant current harmonics are encountered when a generic inverter is used. However, ripples are attenuated significantly when a custom design inverter is used. Further, fault conditions are considered for real world case studies such as running out of hydrogen, a malfunction in the system, or an unprecedented operating scheme. Some design guidelines are suggested for hybridization of the backup power unit for an uninterrupted operation.
Backup Mechanical Brake System of the Wind Turbine
NASA Astrophysics Data System (ADS)
Sirotkin, E. A.; Solomin, E. V.; Gandzha, S. A.; Kirpichnikova, I. M.
2018-01-01
Paper clarifies the necessity of the emergency mechanical brake systems usage for wind turbines. We made a deep analysis of the wind turbine braking methods available on the market, identifying their strengths and weaknesses. The electromechanical braking appeared the most technically reasonable and economically attractive. We described the developed combined electromechanical brake system for vertical axis wind turbine driven from electric drive with variable torque enough to brake over the turbine even on the storm wind speed up to 45 m/s. The progress was made due to the development of specific kinematic brake system diagram and intelligent control system managed by special operation algorithm.
76 FR 79553 - Maintaining Access to Emergency Liquidity
Federal Register 2010, 2011, 2012, 2013, 2014
2011-12-22
... backup federal liquidity sources for use in times of financial emergency and distressed economic circumstances. The Board also seeks comment on how such a regulation could be implemented to maximize economic... Comment I. Background a. Why may a rule be necessary? The recent financial crisis and lingering economic...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-05
... Statement Adopted Under Rule 205 Entitled ``Back-up Communication Channel to Internet Access'' August 29... ``Back-up Communication Channel to Internet Access'' requiring clearing members that use the Internet as their primary means to access OCC's information and data systems to maintain a secure back-up means of...
International Space Station alpha remote manipulator system workstation controls test report
NASA Astrophysics Data System (ADS)
Ehrenstrom, William A.; Swaney, Colin; Forrester, Patrick
1994-05-01
Previous development testing for the space station remote manipulator system workstation controls determined the need for hardware controls for the emergency stop, brakes on/off, and some camera functions. This report documents the results of an evaluation to further determine control implementation requirements, requested by the Canadian Space Agency (CSA), to close outstanding review item discrepancies. This test was conducted at the Johnson Space Center's Space Station Mockup and Trainer Facility in Houston, Texas, with nine NASA astronauts and one CSA astronaut as operators. This test evaluated camera iris and focus, back-up drive, latching end effector release, and autosequence controls using several types of hardware and software implementations. Recommendations resulting from the testing included providing guarded hardware buttons to prevent accidental actuation, providing autosequence controls and back-up drive controls on a dedicated hardware control panel, and that 'latch on/latch off', or on-screen software, controls not be considered. Generally, the operators preferred hardware controls although other control implementations were acceptable. The results of this evaluation will be used along with further testing to define specific requirements for the workstation design.
International Space Station alpha remote manipulator system workstation controls test report
NASA Technical Reports Server (NTRS)
Ehrenstrom, William A.; Swaney, Colin; Forrester, Patrick
1994-01-01
Previous development testing for the space station remote manipulator system workstation controls determined the need for hardware controls for the emergency stop, brakes on/off, and some camera functions. This report documents the results of an evaluation to further determine control implementation requirements, requested by the Canadian Space Agency (CSA), to close outstanding review item discrepancies. This test was conducted at the Johnson Space Center's Space Station Mockup and Trainer Facility in Houston, Texas, with nine NASA astronauts and one CSA astronaut as operators. This test evaluated camera iris and focus, back-up drive, latching end effector release, and autosequence controls using several types of hardware and software implementations. Recommendations resulting from the testing included providing guarded hardware buttons to prevent accidental actuation, providing autosequence controls and back-up drive controls on a dedicated hardware control panel, and that 'latch on/latch off', or on-screen software, controls not be considered. Generally, the operators preferred hardware controls although other control implementations were acceptable. The results of this evaluation will be used along with further testing to define specific requirements for the workstation design.
Business Case for Fuel Cells 2016
DOE Office of Scientific and Technical Information (OSTI.GOV)
Curtin, Sandra; Gangi, Jennifer; Benjamin, Thomas G.
The report provides an overview of recent private sector fuel cell installations at U.S. businesses as of December 31, 2016. This list is by no means exhaustive. Over the past few decades, hundreds of thousands of fuel cells have been installed around the world, for primary or backup power, as well as in various other applications including portable and emergency backup power. Fuel cells have also been deployed in other applications such as heat and electricity for homes and apartments, material handling, passenger vehicles, buses, and remote, off-grid sites.
STS-55 backup Payload Specialist Thiele with technician in JSC's WETF
NASA Technical Reports Server (NTRS)
1992-01-01
STS-55 Columbia, Orbiter Vehicle (OV) 102, backup German Payload Specialist Dr. P. Gerhard Thiele, wearing launch and entry suit (LES), launch and entry helmet (LEH), and parachute, seated on the poolside waits his turn to participate in launch emergency egress (bailout) exercises. The session, held in JSC's Weightless Environment Training Facility (WETF) Bldg 29, used the facility's 25-foot deep pool to simulate the ocean as Thiele and other crewmembers practiced water bailout procedures. Thiele represents the DLR for the upcoming Spacelab Deutsche 2 (SL-D2) mission.
Economical Video Monitoring of Traffic
NASA Technical Reports Server (NTRS)
Houser, B. C.; Paine, G.; Rubenstein, L. D.; Parham, O. Bruce, Jr.; Graves, W.; Bradley, C.
1986-01-01
Data compression allows video signals to be transmitted economically on telephone circuits. Telephone lines transmit television signals to remote traffic-control center. Lines also carry command signals from center to TV camera and compressor at highway site. Video system with television cameras positioned at critical points on highways allows traffic controllers to determine visually, almost immediately, exact cause of traffic-flow disruption; e.g., accidents, breakdowns, or spills, almost immediately. Controllers can then dispatch appropriate emergency services and alert motorists to minimize traffic backups.
Distributed intrusion monitoring system with fiber link backup and on-line fault diagnosis functions
NASA Astrophysics Data System (ADS)
Xu, Jiwei; Wu, Huijuan; Xiao, Shunkun
2014-12-01
A novel multi-channel distributed optical fiber intrusion monitoring system with smart fiber link backup and on-line fault diagnosis functions was proposed. A 1× N optical switch was intelligently controlled by a peripheral interface controller (PIC) to expand the fiber link from one channel to several ones to lower the cost of the long or ultra-long distance intrusion monitoring system and also to strengthen the intelligent monitoring link backup function. At the same time, a sliding window auto-correlation method was presented to identify and locate the broken or fault point of the cable. The experimental results showed that the proposed multi-channel system performed well especially whenever any a broken cable was detected. It could locate the broken or fault point by itself accurately and switch to its backup sensing link immediately to ensure the security system to operate stably without a minute idling. And it was successfully applied in a field test for security monitoring of the 220-km-length national borderline in China.
An application of Six Sigma methodology to turnover intentions in health care.
Taner, Mehmet
2009-01-01
The purpose of this study is to show how the principles of Six Sigma can be applied to the high turnover problem of doctors in medical emergency services and paramedic backup. Six Sigma's define-measure-analyse-improve-control (DMAIC) is applied for reducing the turnover rate of doctors in an organisation operating in emergency services. Variables of the model are determined. Explanatory factor analysis, multiple regression, analysis of variance (ANOVA) and Gage R&R are employed for the analysis. Personal burnout/stress and dissatisfaction from salary were found to be the "vital few" variables. The organisation took a new approach by improving its initiatives to doctors' working conditions. Sigma level of the process is increased. New policy and process changes have been found to effectively decrease the incidence of turnover intentions. The improved process is gained, standardised and institutionalised. This study is one of the few papers in the literature that elaborates the turnover problem of doctors working in the emergency and paramedic backup services.
The impact of a large-scale power outage on hemodialysis center operations.
Abir, Mahshid; Jan, Sophia; Jubelt, Lindsay; Merchant, Raina M; Lurie, Nicole
2013-12-01
On June 29, 2012, mid-Atlantic storms resulted in a large-scale power outage affecting up to three million people across multiple (US) states. Hemodialysis centers are dependent on electricity to provide dialysis care to end-stage renal disease patients. The objective of this study was to determine how the power outage impacted operations in a sample of hemodialysis centers in the impacted regions. The sample consisted of all hemodialysis centers located in the District of Columbia and a total of five counties with the largest power losses in West Virginia, Virginia, and Maryland. A semi-structured interview guide was developed, and the charge nurse or supervisor in each facility was interviewed. The survey questions addressed whether their centers lost power, if so, for how long, where their patients received dialysis, whether their centers had backup generators, and if so, whether they had any problems operating them, and whether their center received patients from other centers if they had power. Calls were placed to 90 dialysis centers in the sampled areas and a 90% response rate was achieved. Overall, hemodialysis operations at approximately 30% (n = 24) of the centers queried were impacted by the power outage. Of the 36 centers that lost power, 31% (n = 11) referred their patients to other dialysis centers, 22% (n = 8) accommodated their patients during a later shift or on a different day; the rest of the centers either experienced brief power outages that did not affect operations or experienced a power outage on days that the center is usually closed. Some centers in the study cohort reported receiving patients from other centers for dialysis 33% (n = 27). Thirty-two percent (n = 26) of the centers queried had backup generators on site. Eleven percent (n = 4) of the centers experiencing power outages reported that backup generators were brought in by their parent companies. Comprehensive emergency planning for dialysis centers should include provisions for having backup generators on site, having plans in place for the timely delivery of a generator during a power outage, or having predesignated backup dialysis centers for patients to receive dialysis during emergencies. Most dialysis centers surveyed in this study were able to sustain continuity of care by implementing such pre-existing emergency plans.
30 CFR 75.1101-21 - Back-up water system.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Back-up water system. 75.1101-21 Section 75.1101-21 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY... water system. One fire hose outlet together with a length of hose capable of extending to the belt drive...
30 CFR 75.1101-21 - Back-up water system.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Back-up water system. 75.1101-21 Section 75.1101-21 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY... water system. One fire hose outlet together with a length of hose capable of extending to the belt drive...
30 CFR 75.1101-21 - Back-up water system.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Back-up water system. 75.1101-21 Section 75.1101-21 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY... water system. One fire hose outlet together with a length of hose capable of extending to the belt drive...
30 CFR 75.1101-21 - Back-up water system.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Back-up water system. 75.1101-21 Section 75.1101-21 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY... water system. One fire hose outlet together with a length of hose capable of extending to the belt drive...
30 CFR 75.1101-21 - Back-up water system.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Back-up water system. 75.1101-21 Section 75.1101-21 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY... water system. One fire hose outlet together with a length of hose capable of extending to the belt drive...
Kapich, Davorin D.
1987-01-01
A bearing system includes backup bearings for supporting a rotating shaft upon failure of primary bearings. In the preferred embodiment, the backup bearings are rolling element bearings having their rolling elements disposed out of contact with their associated respective inner races during normal functioning of the primary bearings. Displacement detection sensors are provided for detecting displacement of the shaft upon failure of the primary bearings. Upon detection of the failure of the primary bearings, the rolling elements and inner races of the backup bearings are brought into mutual contact by axial displacement of the shaft.
NASA Technical Reports Server (NTRS)
Roskam, Jan; Ackers, Deane E.; Gerren, Donna S.
1995-01-01
A propulsion controlled aircraft (PCA) system has been developed at NASA Dryden Flight Research Center at Edwards Air Force Base, California, to provide safe, emergency landing capability should the primary flight control system of the aircraft fail. As a result of the successful PCA work being done at NASA Dryden, this project investigated the possibility of incorporating the PCA system as a backup flight control system in the design of a large, ultra-high capacity megatransport in such a way that flight path control using only the engines is not only possible, but meets MIL-Spec Level 1 or Level 2 handling quality requirements. An 800 passenger megatransport aircraft was designed and programmed into the NASA Dryden simulator. Many different analysis methods were used to evaluate the flying qualities of the megatransport while using engine thrust for flight path control, including: (1) Bode and root locus plot analysis to evaluate the frequency and damping ratio response of the megatransport; (2) analysis of actual simulator strip chart recordings to evaluate the time history response of the megatransport; and (3) analysis of Cooper-Harper pilot ratings by two NaSA test pilots.
NASA Astrophysics Data System (ADS)
Kratov, Sergey
2018-01-01
Modern information systems designed to service a wide range of users, regardless of their subject area, are increasingly based on Web technologies and are available to users via Internet. The article discusses the issues of providing the fault-tolerant operation of such information systems, based on free and open source content management systems. The toolkit available to administrators of similar systems is shown; the scenarios for using these tools are described. Options for organizing backups and restoring the operability of systems after failures are suggested. Application of the proposed methods and approaches allows providing continuous monitoring of the state of systems, timely response to the emergence of possible problems and their prompt solution.
The depth of the honeybee's backup sun-compass systems.
Dovey, Katelyn M; Kemfort, Jordan R; Towne, William F
2013-06-01
Honeybees have at least three compass mechanisms: a magnetic compass; a celestial or sun compass, based on the daily rotation of the sun and sun-linked skylight patterns; and a backup celestial compass based on a memory of the sun's movements over time in relation to the landscape. The interactions of these compass systems have yet to be fully elucidated, but the celestial compass is primary in most contexts, the magnetic compass is a backup in certain contexts, and the bees' memory of the sun's course in relation to the landscape is a backup system for cloudy days. Here we ask whether bees have any further compass systems, for example a memory of the sun's movements over time in relation to the magnetic field. To test this, we challenged bees to locate the sun when their known celestial compass systems were unavailable, that is, under overcast skies in unfamiliar landscapes. We measured the bees' knowledge of the sun's location by observing their waggle dances, by which foragers indicate the directions toward food sources in relation to the sun's compass bearing. We found that bees have no celestial compass systems beyond those already known: under overcast skies in unfamiliar landscapes, bees attempt to use their landscape-based backup system to locate the sun, matching the landscapes or skylines at the test sites with those at their natal sites as best they can, even if the matches are poor and yield weak or inconsistent orientation.
40 CFR 243.202-2 - Recommended procedures: Design.
Code of Federal Regulations, 2010 CFR
2010-07-01
... collection vehicles: (1) Exterior rear-view mirrors. (2) Back-up lights. (3) Four-way emergency flashers. (4... conserve fuel and minimize pollution should be used in collection vehicles to reduce fuel consumption and air pollution. ...
Hybrid Propulsion Technologies for Urban Bus Transit
DOT National Transportation Integrated Search
1984-11-01
Information on hybrid propulsion technologies is presented to increase the transit community's awareness and understanding of bus propulsion designs that offer extended use capability for trolley-emergency, short-range, and back-up propulsion for tro...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-17
... Corporation Including Express Employment Professionals. 74,111 Alstom Transportation, Hornell, NY May 14, 2009... Serv., Server Systems, IC1, Storage, Backup. 74,316A International Business Cambridge, MA......... June 10, 2009. Machines (IBM), Global Tech Serv., Server Systems, IC1, Storage, Backup. 74,316B...
Enhanced networked server management with random remote backups
NASA Astrophysics Data System (ADS)
Kim, Song-Kyoo
2003-08-01
In this paper, the model is focused on available server management in network environments. The (remote) backup servers are hooked up by VPN (Virtual Private Network) and replace broken main severs immediately. A virtual private network (VPN) is a way to use a public network infrastructure and hooks up long-distance servers within a single network infrastructure. The servers can be represent as "machines" and then the system deals with main unreliable and random auxiliary spare (remote backup) machines. When the system performs a mandatory routine maintenance, auxiliary machines are being used for backups during idle periods. Unlike other existing models, the availability of auxiliary machines is changed for each activation in this enhanced model. Analytically tractable results are obtained by using several mathematical techniques and the results are demonstrated in the framework of optimized networked server allocation problems.
The Design of Data Disaster Recovery of National Fundamental Geographic Information System
NASA Astrophysics Data System (ADS)
Zhai, Y.; Chen, J.; Liu, L.; Liu, J.
2014-04-01
With the development of information technology, data security of information system is facing more and more challenges. The geographic information of surveying and mapping is fundamental and strategic resource, which is applied in all areas of national economic, defence and social development. It is especially vital to national and social interests when such classified geographic information is directly concerning Chinese sovereignty. Several urgent problems that needs to be resolved for surveying and mapping are how to do well in mass data storage and backup, establishing and improving the disaster backup system especially after sudden natural calamity accident, and ensuring all sectors rapidly restored on information system will operate correctly. For overcoming various disaster risks, protect the security of data and reduce the impact of the disaster, it's no doubt the effective way is to analysis and research on the features of storage and management and security requirements, as well as to ensure that the design of data disaster recovery system suitable for the surveying and mapping. This article analyses the features of fundamental geographic information data and the requirements of storage management, three site disaster recovery system of DBMS plan based on the popular network, storage and backup, data replication and remote switch of application technologies. In LAN that synchronous replication between database management servers and the local storage of backup management systems, simultaneously, remote asynchronous data replication between local storage backup management systems and remote database management servers. The core of the system is resolving local disaster in the remote site, ensuring data security and business continuity of local site. This article focuses on the following points: background, the necessity of disaster recovery system, the analysis of the data achievements and data disaster recovery plan. Features of this program is to use a hardware-based data hot backup, and remote online disaster recovery support for Oracle database system. The achievement of this paper is in summarizing and analysing the common characteristics of disaster of surveying and mapping business system requirements, while based on the actual situation of the industry, designed the basic GIS disaster recovery solutions, and we also give the conclusions about key technologies of RTO and RPO.
Passive cooling system for liquid metal cooled nuclear reactors with backup coolant flow path
Hunsbedt, Anstein; Boardman, Charles E.
1993-01-01
A liquid metal cooled nuclear fission reactor plant having a passive auxiliary safety cooling system for removing residual heat resulting from fuel decay during reactor shutdown, or heat produced during a mishap. This reactor plant is enhanced by a backup or secondary passive safety cooling system which augments the primary passive auxiliary cooling system when in operation, and replaces the primary system when rendered inoperable.
Mathematical defense method of networked servers with controlled remote backups
NASA Astrophysics Data System (ADS)
Kim, Song-Kyoo
2006-05-01
The networked server defense model is focused on reliability and availability in security respects. The (remote) backup servers are hooked up by VPN (Virtual Private Network) with high-speed optical network and replace broken main severs immediately. The networked server can be represent as "machines" and then the system deals with main unreliable, spare, and auxiliary spare machine. During vacation periods, when the system performs a mandatory routine maintenance, auxiliary machines are being used for back-ups; the information on the system is naturally delayed. Analog of the N-policy to restrict the usage of auxiliary machines to some reasonable quantity. The results are demonstrated in the network architecture by using the stochastic optimization techniques.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-19
... comply with trip limits. However, the current system does not accurately account for the fish landed for... confirm the receipt of the TSH report via a back-up system specified by the DSM service provider. The... via a back-up system, after a time determined by the DSM provider, to confirm the receipt of the TSH...
Applying secret sharing for HIS backup exchange.
Kuroda, Tomohiro; Kimura, Eizen; Matsumura, Yasushi; Yamashita, Yoshinori; Hiramatsu, Haruhiko; Kume, Naoto; Sato, Atsushi
2013-01-01
To secure business continuity is indispensable for hospitals to fulfill its social responsibility under disasters. Although to back up the data of the hospital information system (HIS) at multiple remote sites is a key strategy of business continuity plan (BCP), the requirements to treat privacy sensitive data jack up the cost for the backup. The secret sharing is a method to split an original secret message up so that each individual piece is meaningless, but putting sufficient number of pieces together to reveal the original message. The secret sharing method eases us to exchange HIS backups between multiple hospitals. This paper evaluated the feasibility of the commercial secret sharing solution for HIS backup through several simulations. The result shows that the commercial solution is feasible to realize reasonable HIS backup exchange platform when template of contract between participating hospitals is ready.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-16
... Systems: Backup Power Private Land Mobile Radio Services: Selection and Assignment of Frequencies, and... certain rule provisions that are without current legal effect and obsolete. These nonsubstantive revisions... current legal effect and is deleted as obsolete. 2. This Order also deletes a rule providing that UHF...
Green, Robert S; Fergusson, Dean A; Turgeon, Alexis F; McIntyre, Lauralyn A; Kovacs, George J; Griesdale, Donald E; Zarychanski, Ryan; Butler, Michael B; Kureshi, Nelofar; Erdogan, Mete
2017-05-01
Various medications and devices are available for facilitation of emergent endotracheal intubations (EETIs). The objective of this study was to survey which medications and devices are being utilized for intubation by Canadian physicians. A clinical scenario-based survey was developed to determine which medications physicians would administer to facilitate EETI, their first choice of intubation device, and backup strategy should their first choice fail. The survey was distributed to Canadian emergency medicine (EM) and intensive care unit (ICU) physicians using web-based and postal methods. Physicians were asked questions based on three scenarios (trauma; pneumonia; heart failure) and responded using a 5-point scale ranging from "always" to "never" to capture usual practice. The survey response rate was 50.2% (882/1,758). Most physicians indicated a Macintosh blade with direct laryngoscopy would "always/often" be their first choice of intubation device in the three scenarios (mean 85% [79%-89%]) followed by video laryngoscopy (mean 37% [30%-49%]). The most common backup device chosen was an extraglottic device (mean 59% [56%-60%]). The medications most physicians would "always/often" administer were fentanyl (mean 45% [42%-51%]) and etomidate (mean 38% [25%-50%]). EM physicians were more likely than ICU physicians to paralyze patients for EETI (adjusted odds ratio 3.40; 95% CI 2.90-4.00). Most EM and ICU physicians utilize direct laryngoscopy with a Macintosh blade as a primary device for EETI and an extraglottic device as a backup strategy. This survey highlights variation in Canadian practice patterns for some aspects of intubation in critically ill patients.
NASA Astrophysics Data System (ADS)
Li, Jie; Duan, Minghu; Yan, Maode; Li, Gang; Li, Xiaohui
2014-06-01
A full authority digital electronic controller (FADEC) equipped with a full authority hydro-mechanical backup controller (FAHMBC) is adopted as the nozzle throat area control system (NTACS) of a turbofan aero engine. In order to ensure the switching reliability of the main/backup controller, the nozzle throat area control switching valve was improved from three-way convex desktop slide valve to six-way convex desktop slide valve. Simulation results show that, if malfunctions of FAEDC occur and abnormal signals are outputted from FADEC, NTACS will be seriously influenced by the main/backup controller switching in several working states, while NTACS will not be influenced by using the improved nozzle throat area control switching valve, thus the controller switching process will become safer and smoother and the working reliability of this turbofan aero engine is improved by the controller switching device improvement.
STS-108 backup crew member Robinson in an M-113
NASA Technical Reports Server (NTRS)
2001-01-01
KENNEDY SPACE CENTER, Fla. -- Astronaut Stephen K. Robinson takes his turn at driving an M-113 armored personnel carrier. Robinson is a backup crew member for the International Space Station Expedition 4 crew, who are flying on Space Shuttle Endeavour as part of mission STS-108. Both the mission crew and Expedition 4 crews are at KSC for Terminal Countdown Demonstration Test activities. The TCDT includes emergency exit from the launch pad and a simulated launch countdown. The 11-day mission will also carry the Multi-Purpose Logistics Module Raffaello, filled with supplies and equipment. STS-108 is scheduled to launch Nov. 29.
Hydrogen Fuel Cell Performance as Telecommunications Backup Power in the United States
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kurtz, Jennifer; Saur, Genevieve; Sprik, Sam
2015-03-01
Working in collaboration with the U.S. Department of Energy (DOE) and industry project partners, the National Renewable Energy Laboratory (NREL) acts as the central data repository for the data collected from real-world operation of fuel cell backup power systems. With American Recovery and Reinvestment Act of 2009 (ARRA) co-funding awarded through DOE's Fuel Cell Technologies Office, more than 1,300 fuel cell units were deployed over a three-plus-year period in stationary, material handling equipment, auxiliary power, and backup power applications. This surpassed a Fuel Cell Technologies Office ARRA objective to spur commercialization of an early market technology by installing 1,000 fuelmore » cell units across several different applications, including backup power. By December 2013, 852 backup power units out of 1,330 fuel cell units deployed were providing backup service, mainly for telecommunications towers. For 136 of the fuel cell backup units, project participants provided detailed operational data to the National Fuel Cell Technology Evaluation Center for analysis by NREL's technology validation team. NREL analyzed operational data collected from these government co-funded demonstration projects to characterize key fuel cell backup power performance metrics, including reliability and operation trends, and to highlight the business case for using fuel cells in these early market applications. NREL's analyses include these critical metrics, along with deployment, U.S. grid outage statistics, and infrastructure operation.« less
NASA Technical Reports Server (NTRS)
Roumeliotis, Chris; Grinblat, Jonathan; Reeves, Glenn
2013-01-01
Second Chance (SECC) was a bare bones version of Mars Science Laboratory's (MSL) Entry Descent & Landing (EDL) flight software that ran on Curiosity's backup computer, which could have taken over swiftly in the event of a reset of Curiosity's prime computer, in order to land her safely on Mars. Without SECC, a reset of Curiosity's prime computer would have lead to catastrophic mission failure. Even though a reset of the prime computer never occurred, SECC had the important responsibility as EDL's guardian angel, and this responsibility would not have seen such success without unparalleled systems engineering. This paper will focus on the systems engineering behind SECC: Covering a brief overview of SECC's design, the intense schedule to use SECC as a backup system, the verification and validation of the system's "Do No Harm" mandate, the system's overall functional performance, and finally, its use on the fateful day of August 5th, 2012.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-04-13
... of the related balance washer causing a possible ram air turbine (RAT) imbalance event, which may... in loss of power to airplane flight controls hydraulic back-up system. * * * * * Loss of power to the hydraulic back-up system for airplane flight controls could reduce the ability of the flightcrew to maintain...
Assessment of industrial applications for fuel cell cogeneration systems
NASA Technical Reports Server (NTRS)
Stickles, R. P.; Oneill, J. K.; Smith, E. H.
1978-01-01
The fuel cell energy systems are designed with and without a utility connection for emergency back-up power. Sale of electricity to the utility during periods of low plant demand is not considered. For each of the three industrial applications, conceptual designs were also developed for conventional utility systems relying on purchased electric power and fossil-fired boilers for steam/hot water. The capital investment for each energy system is estimated. Annual operating costs are also determined for each system. These cost estimates are converted to levelized annual costs by applying appropriate economic factors. The breakeven electricity price that would make fuel cell systems competitive with the conventional systems is plotted as a function of naphtha price. The sensitivity of the breakeven point to capital investment and coal price is also evaluated.
Fuel Storage Tanks at FAA Facilities: Order 1050.15A
DOT National Transportation Integrated Search
1997-04-30
The Federal Aviation Administration (FAA) has over 4,000 fuel storage tanks (FST) in its : inventory. Most of these FSTs are underground storage tanks (UST) that contain fuel for : emergency backup generators providing secondary power to air navigati...
Summary of Part 75 Administrative Processes: Table 6
Learn how to submit information for a new unit, new stack or new FGD; unit shutdown and restart, long term cold storage (LTCS), expected restart date, postponement of Appendix E testing, backup fuel used, and notice of combustion of emergency fuel.
Mechanical Backup For Fly-By-Wire Control System
NASA Technical Reports Server (NTRS)
Stewart, Eric C.
1992-01-01
Mechanical device eliminates need for redundant fly-by-wire subsystems. Main components are two linkages. One connected to control column in conventional, reversible control system. Other slides inside first linkage and connected to pilot's control wheel. In addition to aircraft applications, design used in control systems in which computer control desirable but safety backup systems required; for example, in boat rudders, engine controls in boats and automobiles, and controls in construction equipment.
DOE Office of Scientific and Technical Information (OSTI.GOV)
WHITE, W.F.
2000-04-04
The purpose of this document is to provide the definition and means of maintaining the safety envelope (SE) for the Emergency Notification and Evacuation System (ENES). Together with the appendices, it provides: (1) The system requirements for determining system operability (Section 3.0); (2) Evaluations of equipment to determine the safety boundary for the system (Section 4.0); (3) List of system drawings that are annotated to show the SE boundaries (Appendix A); (4) Identification of the SE equipment by reference to systems and drawings (Appendix B); (5) Requirements for the individual SE equipment (Section 4.0); and (6) A list of themore » operational and surveillance procedures necessary to operate and maintain the system equipment within the SE (Sections 5.0 and 6.0). The Private Automatic Exchange (PAX) phones and PAX switchers are outside the safety envelope defined in WHC-SD-CP-OSR-010, Section 5.4.10, ''Safety Communication and Alarm Systems,'' Section 5.4.1 0.1, ''Major Components and Operating Characteristics,'' and Section 5.4.10.1.12, ''PAX System.'' The PAX override microphone system maintains the safety envelope, and functions as a backup to the evacuation sirens during an emergency.« less
An approach to secure weather and climate models against hardware faults
NASA Astrophysics Data System (ADS)
Düben, Peter D.; Dawson, Andrew
2017-03-01
Enabling Earth System models to run efficiently on future supercomputers is a serious challenge for model development. Many publications study efficient parallelization to allow better scaling of performance on an increasing number of computing cores. However, one of the most alarming threats for weather and climate predictions on future high performance computing architectures is widely ignored: the presence of hardware faults that will frequently hit large applications as we approach exascale supercomputing. Changes in the structure of weather and climate models that would allow them to be resilient against hardware faults are hardly discussed in the model development community. In this paper, we present an approach to secure the dynamical core of weather and climate models against hardware faults using a backup system that stores coarse resolution copies of prognostic variables. Frequent checks of the model fields on the backup grid allow the detection of severe hardware faults, and prognostic variables that are changed by hardware faults on the model grid can be restored from the backup grid to continue model simulations with no significant delay. To justify the approach, we perform model simulations with a C-grid shallow water model in the presence of frequent hardware faults. As long as the backup system is used, simulations do not crash and a high level of model quality can be maintained. The overhead due to the backup system is reasonable and additional storage requirements are small. Runtime is increased by only 13 % for the shallow water model.
An approach to secure weather and climate models against hardware faults
NASA Astrophysics Data System (ADS)
Düben, Peter; Dawson, Andrew
2017-04-01
Enabling Earth System models to run efficiently on future supercomputers is a serious challenge for model development. Many publications study efficient parallelisation to allow better scaling of performance on an increasing number of computing cores. However, one of the most alarming threats for weather and climate predictions on future high performance computing architectures is widely ignored: the presence of hardware faults that will frequently hit large applications as we approach exascale supercomputing. Changes in the structure of weather and climate models that would allow them to be resilient against hardware faults are hardly discussed in the model development community. We present an approach to secure the dynamical core of weather and climate models against hardware faults using a backup system that stores coarse resolution copies of prognostic variables. Frequent checks of the model fields on the backup grid allow the detection of severe hardware faults, and prognostic variables that are changed by hardware faults on the model grid can be restored from the backup grid to continue model simulations with no significant delay. To justify the approach, we perform simulations with a C-grid shallow water model in the presence of frequent hardware faults. As long as the backup system is used, simulations do not crash and a high level of model quality can be maintained. The overhead due to the backup system is reasonable and additional storage requirements are small. Runtime is increased by only 13% for the shallow water model.
Wind power systems for individual applications. [electric power supplies for homes
NASA Technical Reports Server (NTRS)
Clews, H. M.
1973-01-01
A small windpower system is described which is suitable for electrifying a house. The self-contained unit consists of a two kilowatt wind driven generator, a set of 19 storage batteries, a small dc to ac inverter, and a gasoline generator for use as an emergency backup system in case of prolonged calm periods. Cost effectiveness of the electricity generated by this windmill system comes out to about 15 cents per kilowatt hour - assuming a 10 year life for the batteries and a 20 year life for the other components. Some other small windpower systems are also described, and it is shown that a windpowered generator in the 15- to 25-kilowatt output range coupled to a direct heated water storage system is able to heat a typical New England home.
Fuel storage tanks at FAA facilities : Order 1050.15A : executive summary.
DOT National Transportation Integrated Search
1997-04-30
The Federal Aviation Administration (FAA) has over 4,000 fuel storage tanks (FST) in its inventory. Most of these FSTs are underground storage tanks (UST) that contain fuel for emergency backup generators providing secondary power to air navigational...
Photographic coverage of EXP 7 during NBL training
2002-10-28
JSC2002-01972 (28 October 2002) --- Cosmonaut Sergei K. Krikalev, backup Expedition Seven mission commander, floats in a small life raft during an emergency bailout training session in the Neutral Buoyancy Laboratory (NBL) near the Johnson Space Center (JSC). Krikalev represents Rosaviakosmos.
Teammate Familiarity, Teamwork, and Risk of Workplace Injury in Emergency Medical Services Teams.
Hughes, Ashley M; Patterson, P Daniel; Weaver, Matthew D; Gregory, Megan E; Sonesh, Shirley C; Landsittel, Douglas P; Krackhardt, David; Hostler, David; Lazzara, Elizabeth H; Wang, Xiao; Vena, John E; Salas, Eduardo; Yealy, Donald M
2017-07-01
Increased teammate familiarity in emergency medical services (EMS) promotes development of positive teamwork and protects against workplace injury. Measures were collected using archival shift records, workplace injury data, and cross-sectional surveys from a nationally representative sample of 14 EMS agencies employing paramedics, prehospital nurses, and other EMS clinicians. One thousand EMS clinicians were selected at random to complete a teamwork survey for each of their recent partnerships and tested the hypothesized role of teamwork as a mediator in the relationship between teammate familiarity and injury with the PROCESS macro. We received 2566 completed surveys from 333 clinicians, of which 297 were retained. Mean participation was 40.5% (standard deviation [SD] = 20.5%) across EMS agencies. Survey respondents were primarily white (93.8%), male (67.3%), and ranged between 21-62 years of age (M = 37.4, SD = 9.7). Seventeen percent were prehospital nurses. Respondents worked a mean of 3 shifts with recent teammates in the 8 weeks preceding the survey (M = 3.06, SD = 4.4). We examined data at the team level, which suggest positive views of teamwork (M = 5.92, SD = 0.69). Our hypothesis that increased teammate familiarity protects against adverse safety outcomes through development of positive teamwork was not supported. Teamwork factor Partner Adaptability and Backup Behavior is a likely mediator (odds ratio = 1.03, P = .05). When dyad familiarity is high and there are high levels of backup behavior, the likelihood of injury is increased. The relationship between teammate familiarity and outcomes is complex. Teammate adaptation and backup behavior is a likely mediator of this relationship in EMS teams with greater familiarity. Copyright © 2017 Emergency Nurses Association. Published by Elsevier Inc. All rights reserved.
The Business Case for Fuel Cells: Delivering Sustainable Value
DOE Office of Scientific and Technical Information (OSTI.GOV)
Curtin, Sandra; Gangi, Jennifer
This report, written and compiled by Argonne National Laboratory and the Fuel Cell and Hydrogen Energy Association with support from the Fuel Cell Technologies Office, provides an overview of private sector fuel cell installations at U.S. businesses as of December 31, 2016. Over the past few decades, hundreds of thousands of fuel cells have been installed around the world, for primary or backup power, as well as in various other applications including portable and emergency backup power. Fuel cells have also been deployed in other applications such as heat and electricity for homes and apartments, material handling, passenger vehicles, buses,more » and remote, off-grid sites.« less
Kidd, David G; Brethwaite, Andrew
2014-05-01
This study identified the areas behind vehicles where younger and older children are not visible and measured the extent to which vehicle technologies improve visibility. Rear visibility of targets simulating the heights of a 12-15-month-old, a 30-36-month-old, and a 60-72-month-old child was assessed in 21 2010-2013 model year passenger vehicles with a backup camera or a backup camera plus parking sensor system. The average blind zone for a 12-15-month-old was twice as large as it was for a 60-72-month-old. Large SUVs had the worst rear visibility and small cars had the best. Increases in rear visibility provided by backup cameras were larger than the non-visible areas detected by parking sensors, but parking sensors detected objects in areas near the rear of the vehicle that were not visible in the camera or other fields of view. Overall, backup cameras and backup cameras plus parking sensors reduced the blind zone by around 90 percent on average and have the potential to prevent backover crashes if drivers use the technology appropriately. Copyright © 2014 Elsevier Ltd. All rights reserved.
Analog neural network control method proposed for use in a backup satellite control mode
DOE Office of Scientific and Technical Information (OSTI.GOV)
Frigo, J.R.; Tilden, M.W.
1998-03-01
The authors propose to use an analog neural network controller implemented in hardware, independent of the active control system, for use in a satellite backup control mode. The controller uses coarse sun sensor inputs. The field of view of the sensors activate the neural controller, creating an analog dead band with respect to the direction of the sun on each axis. This network controls the orientation of the vehicle toward the sunlight to ensure adequate power for the system. The attitude of the spacecraft is stabilized with respect to the ambient magnetic field on orbit. This paper develops a modelmore » of the controller using real-time coarse sun sensor data and a dynamic model of a prototype system based on a satellite system. The simulation results and the feasibility of this control method for use in a satellite backup control mode are discussed.« less
Feasibility analysis of a hydrogen backup power system for Russian telecom market
NASA Astrophysics Data System (ADS)
Borzenko, V. I.; Dunikov, D. O.
2017-11-01
We performed feasibility analysis of 10 kW hydrogen backup power system (H2BS) consisting of a water electrolyzer, a metal hydride hydrogen storage and a fuel cell. Capital investments in H2BS are mostly determined by the costs of the PEM electrolyzer, the fuel cell and solid state hydrogen storage materials, for single unit or small series manufacture the cost of AB5-type intermetallic compound can reach 50% of total system cost. Today the capital investments in H2BS are 3 times higher than in conventional lead-acid system of the same capacity. Wide distribution of fuel cell hydrogen vehicles, development of hydrogen infrastructure, and mass production of hydrogen power systems will for sure lower capital investments in fuel cell backup power. Operational expenditures for H2BS is only 15% from the expenditures for lead acid systems, and after 4-5 years of exploitation the total cost of ownership will become lower than for batteries.
Zhang, Lulu; Liu, Xu; Li, Youping; Liu, Yuan; Liu, Zhipeng; Lin, Juncong; Shen, Ji; Tang, Xuefeng; Zhang, Yi; Liang, Wannian
2012-03-03
Major earthquakes often result in incalculable environmental damage, loss of life, and threats to health. Tremendous progress has been made in response to many medical challenges resulting from earthquakes. However, emergency medical rescue is complicated, and great emphasis should be placed on its organisation to achieve the best results. The 2008 Wenchuan earthquake was one of the most devastating disasters in the past 10 years and caused more than 370,000 casualties. The lessons learnt from the medical disaster relief effort and the subsequent knowledge gained about the regulation and capabilities of medical and military back-up teams should be widely disseminated. In this Review we summarise and analyse the emergency medical rescue efforts after the Wenchuan earthquake. Establishment of a national disaster medical response system, an active and effective commanding system, successful coordination between rescue forces and government agencies, effective treatment, a moderate, timely and correct public health response, and long-term psychological support are all crucial to reduce mortality and morbidity and promote overall effectiveness of rescue efforts after a major earthquake. Copyright © 2012 Elsevier Ltd. All rights reserved.
A Study of Fuel Supplies for Emergency Power Generation at Air Logistics Centers.
1980-06-01
D-AD087 088 AIR FORCE INST OF TECH WRIGHT-PATTERSON AFB OH SCHOOL--ETC F/. I"/. STUDY OF FUEL SUPPLIES FOR EMERGENCY POWER GENERATION AT AIR -ETCIU...public release; distribution unlimited 17. DISTRIBUTION STATEMENT (at thme abstract sneered lei Black 20. 1 itoINt~ &P 190-17. FlEDiC C. L N uS "il I...operations required by a wartime scenario may depend upon the use of emergency back-up generators to provide electrical power to critical facilities. After
Simulation for Operational Readiness in a New Freestanding Emergency Department
Kerner, Robert L.; Gallo, Kathleen; Cassara, Michael; D'Angelo, John; Egan, Anthony; Simmons, John Galbraith
2016-01-01
Summary Statement Simulation in multiple contexts over the course of a 10-week period served as a core learning strategy to orient experienced clinicians before opening a large new urban freestanding emergency department. To ensure technical and procedural skills of all team members, who would provide care without on-site recourse to specialty backup, we designed a comprehensive interprofessional curriculum to verify and regularize a wide range of competencies and best practices for all clinicians. Formulated under the rubric of systems integration, simulation activities aimed to instill a shared culture of patient safety among the entire cohort of 43 experienced emergency physicians, physician assistants, nurses, and patient technicians, most newly hired to the health system, who had never before worked together. Methods throughout the preoperational term included predominantly hands-on skills review, high-fidelity simulation, and simulation with standardized patients. We also used simulation during instruction in disaster preparedness, sexual assault forensics, and community outreach. Our program culminated with 2 days of in-situ simulation deployed in simultaneous and overlapping timeframes to challenge system response capabilities, resilience, and flexibility; this work revealed latent safety threats, lapses in communication, issues of intake procedure and patient flow, and the persistence of inapt or inapplicable mental models in responding to clinical emergencies. PMID:27607095
Mechanical Component Diagnostic System
1991-01-01
Control and Display Unit ( CADU ) executes the system software and controls data acquisition that is carried out by 6 the Data Acquisition Unit (DAU... CADU screen. Displays intended for the CD are also echoed on the CADU in the FDR backup mode. If initialization is successful, clocks are synchronized...and normal MCDS monitoring mode is entered. If there is no display on the CD, the user may manually switch to the backup CD display on the CADU . Hence
X-wing fly-by-wire vehicle management system
NASA Technical Reports Server (NTRS)
Fischer, Jr., William C. (Inventor)
1990-01-01
A complete, computer based, vehicle management system (VMS) for X-Wing aircraft using digital fly-by-wire technology controlling many subsystems and providing functions beyond the classical aircraft flight control system. The vehicle management system receives input signals from a multiplicity of sensors and provides commands to a large number of actuators controlling many subsystems. The VMS includes--segregating flight critical and mission critical factors and providing a greater level of back-up or redundancy for the former; centralizing the computation of functions utilized by several subsystems (e.g. air data, rotor speed, etc.); integrating the control of the flight control functions, the compressor control, the rotor conversion control, vibration alleviation by higher harmonic control, engine power anticipation and self-test, all in the same flight control computer (FCC) hardware units. The VMS uses equivalent redundancy techniques to attain quadruple equivalency levels; includes alternate modes of operation and recovery means to back-up any functions which fail; and uses back-up control software for software redundancy.
Tracer techniques for urine volume determination and urine collection and sampling back-up system
NASA Technical Reports Server (NTRS)
Ramirez, R. V.
1971-01-01
The feasibility, functionality, and overall accuracy of the use of lithium were investigated as a chemical tracer in urine for providing a means of indirect determination of total urine volume by the atomic absorption spectrophotometry method. Experiments were conducted to investigate the parameters of instrumentation, tracer concentration, mixing times, and methods for incorporating the tracer material in the urine collection bag, and to refine and optimize the urine tracer technique to comply with the Skylab scheme and operational parameters of + or - 2% of volume error and + or - 1% accuracy of amount of tracer added to each container. In addition, a back-up method for urine collection and sampling system was developed and evaluated. This back-up method incorporates the tracer technique for volume determination in event of failure of the primary urine collection and preservation system. One chemical preservative was selected and evaluated as a contingency chemical preservative for the storage of urine in event of failure of the urine cooling system.
Replacement Planning: A Starting Point for Succession Planning and Talent Management
ERIC Educational Resources Information Center
Rothwell, William J.
2011-01-01
Replacement planning is a process of identifying short-term or long-term backups so that organizations have people who can assume responsibility for critical positions during emergencies. Individuals identified as "replacements" are not promised promotions; rather, they are prepared to the point where they can assume a critical position long…
NASA Technical Reports Server (NTRS)
1974-01-01
Operational and configuration checks for the Apollo-Soyuz Test Project are presented. The checks include: backup crew prelaunch, prime crew prelaunch, boost and insertion, G and C reference data, G and N reference modes, rendezvous, navigation, Apollo-Soyuz operations, abort procedures, and emergency procedures.
75 FR 9521 - Drawbridge Operation Regulations; Elizabeth River, Eastern Branch, VA
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-03
... vehicular back-ups, delays, and congestion. During this test deviation, VDOT will gather data from the... patterns in hope of reducing roadway congestion on the bridge and local commuting area by adjusting bridge... evacuation highway in the event of emergencies. The monthly vehicular traffic counts submitted by VDOT for...
Sunlight Helps Laboratory Get Ready for Y2K
by the end of December to provide emergency electricity to the Site Entrance Building (SEB), which solar power if the supply of electricity from the local utility grid is interrupted. The solar generator failure disrupts electricity supplies. If a power failure should be protracted, a secondary propane backup
Engines-only flight control system
NASA Technical Reports Server (NTRS)
Burcham, Frank W. (Inventor); Gilyard, Glenn B (Inventor); Conley, Joseph L. (Inventor); Stewart, James F. (Inventor); Fullerton, Charles G. (Inventor)
1994-01-01
A backup flight control system for controlling the flightpath of a multi-engine airplane using the main drive engines is introduced. The backup flight control system comprises an input device for generating a control command indicative of a desired flightpath, a feedback sensor for generating a feedback signal indicative of at least one of pitch rate, pitch attitude, roll rate and roll attitude, and a control device for changing the output power of at least one of the main drive engines on each side of the airplane in response to the control command and the feedback signal.
Ono, Yuko; Shinohara, Kazuaki; Goto, Aya; Yano, Tetsuhiro; Sato, Lubna; Miyazaki, Hiroyuki; Shimada, Jiro; Tase, Choichiro
2016-04-01
Immediate access to the equipment required for difficult airway management (DAM) is vital. However, in Japan, data are scarce regarding the availability of DAM resources in prehospital settings. The purpose of this study was to determine whether Japanese helicopter emergency medical services (HEMS) are adequately equipped to comply with the DAM algorithms of Japanese and American professional anesthesiology societies. This nationwide cross-sectional study was conducted in May 2015. Base hospitals of HEMS were mailed a questionnaire about their airway management equipment and back-up personnel. Outcome measures were (1) call for help, (2) supraglottic airway device (SGA) insertion, (3) verification of tube placement using capnometry, and (4) the establishment of surgical airways, all of which have been endorsed in various airway management guidelines. The criteria defining feasibility were the availability of (1) more than one physician, (2) SGA, (3) capnometry, and (4) a surgical airway device in the prehospital setting. Of the 45 HEMS base hospitals questioned, 42 (93.3 %) returned completed questionnaires. A surgical airway was practicable by all HEMS. However, in the prehospital setting, back-up assistance was available in 14.3 %, SGA in 16.7 %, and capnometry in 66.7 %. No HEMS was capable of all four steps. In Japan, compliance with standard airway management algorithms in prehospital settings remains difficult because of the limited availability of alternative ventilation equipment and back-up personnel. Prehospital health care providers need to consider the risks and benefits of performing endotracheal intubation in environments not conducive to the success of this procedure.
Emergency preparedness in a sample of persons with disabilities.
Gershon, Robyn R M; Kraus, Lewis E; Raveis, Victoria H; Sherman, Martin F; Kailes, June I
2013-01-01
The objective of this study was to characterize emergency preparedness in this vulnerable population, and to ascertain the role of the personal assistant (PA) and the potential impact of prior emergency experience on preparedness efforts. Cross-sectional Internet-based survey conducted in 2011. Convenience sample. Two-hundred fifty-three community residents with cognitive and /or physical disabilities, all receiving personal assistance services. Emergency preparedness, operationalized as responses to a seven-item scale. The mean score for the emergency preparedness scale was 2.32 (SD = 2.74), range 0-7. Even though 62.8 percent (n = 159) of the participants had previously experienced one or more large-scale emergencies, only 47.4 percent (n = 120) of the entire sample and 55.3 percent (n = 88) of those with actual emergency experience reported preparing an emergency plan. Sixty-three percent (n = 76) of those reporting a plan had involved their PA in its development. Participants who reported such involvement were significantly more likely to have higher scores on the emergency preparedness scale (p < 0.001). Participants who had experienced a prior emergency were also more likely to score higher on the emergency preparedness scale (p < 0.001). In general, participants reported limited attention to other basic preparedness recommendations: only 28 percent (n = 70) had prepared a "go-bag" with necessary supplies, 29 percent (n = 74) had developed a strategy for communicating with their PA during emergencies, and 32 percent (n = 81) had stockpiled emergency supplies. Of particular importance, only 26 percent (n = 66) had made alternative back-up plans for personal assistance. Involving the PA in the planning process and experiencing an emergency were both significantly associated with higher emergency preparedness scores in this sample of people living with disabilities. However, critical deficiencies in preparedness were noted, such as lack of back-up plans for replacing their PA. Despite a concerted national effort to improve preparedness in the population of people living with disabilities, important preparedness gaps remain. These findings highlight the need for additional study on emergency preparedness barriers in people living with disabilities so that effective strategies to reduce vulnerabilities can be identified.
[Research on Zhejiang blood information network and management system].
Yan, Li-Xing; Xu, Yan; Meng, Zhong-Hua; Kong, Chang-Hong; Wang, Jian-Min; Jin, Zhen-Liang; Wu, Shi-Ding; Chen, Chang-Shui; Luo, Ling-Fei
2007-02-01
This research was aimed to develop the first level blood information centralized database and real time communication network at a province area in China. Multiple technology like local area network database separate operation, real time data concentration and distribution mechanism, allopatric backup, and optical fiber virtual private network (VPN) were used. As a result, the blood information centralized database and management system were successfully constructed, which covers all the Zhejiang province, and the real time exchange of blood data was realised. In conclusion, its implementation promote volunteer blood donation and ensure the blood safety in Zhejiang, especially strengthen the quick response to public health emergency. This project lays the first stone of centralized test and allotment among blood banks in Zhejiang, and can serve as a reference of contemporary blood bank information systems in China.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1979-07-01
The objective of the work described in this volume was to conceptualize suitable designs for solar total energy systems for the following residential market segments: single-family detached homes, single-family attached units (townhouses), low-rise apartments, and high-rise apartments. Conceptual designs for the total energy systems are based on parabolic trough collectors in conjunction with a 100 kWe organic Rankine cycle heat engine or a flat-plate, water-cooled photovoltaic array. The ORC-based systems are designed to operate as either independent (stand alone) systems that burn fossil fuel for backup electricity or as systems that purchase electricity from a utility grid for electrical backup.more » The ORC designs are classified as (1) a high temperature system designed to operate at 600/sup 0/F and (2) a low temperature system designed to operate at 300/sup 0/F. The 600/sup 0/F ORC system that purchases grid electricity as backup utilizes the thermal tracking principle and the 300/sup 0/F ORC system tracks the combined thermal and electrical loads. Reject heat from the condenser supplies thermal energy for heating and cooling. All of the ORC systems utilize fossil fuel boilers to supply backup thermal energy to both the primary (electrical generating) cycle and the secondary (thermal) cycle. Space heating is supplied by a central hot water (hydronic) system and a central absorption chiller supplies the space cooling loads. A central hot water system supplies domestic hot water. The photovoltaic system uses a central electrical vapor compression air conditioning system for space cooling, with space heating and domestic hot water provided by reject heat from the water-cooled array. All of the systems incorporate low temperature thermal storage (based on water as the storage medium) and lead--acid battery storage for electricity; in addition, the 600/sup 0/F ORC system uses a therminol-rock high temperature storage for the primary cycle. (WHK)« less
76 FR 46325 - Notice of Lodging of Stipulated Order Under the Clean Water Act
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-02
... located on St. Croix, and (b) implement repairs at the Figtree Pump Station, the Barren Spot Pump Station... emergency backup pump available at the Figtree, Barren Spot, LBJ, and Lagoon Street pump stations located on... the Barren Spot, Lagoon Street, Figtree and LBJ pump stations located on St. Thomas and to the Cancryn...
78 FR 39016 - Office of Presidential Libraries; Proposed Disposal of George H.W. Bush and Clinton...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-28
... for disaster recovery purposes, NARA is following a procedure similar to that in GRS 24 for Federal... made for emergency purposes are not record keeping media; rather, their sole purpose is to be available... backup tapes have already served that purpose and NARA has no need to conduct any further restoration...
[Russian treadmill BD-1 as a backup of the NASA TVIS].
Iarmanova, E N; Kozlovskaia, I B; Bogomolov, V V; Rumiantseva, O N; Sukhachev, V I; Mel'nik, K A
2006-01-01
Already during the early ISS increments malfunctioning of NASA TVIS (treadmill with vibration isolation system) posed major problems for regular crew training and particularly scamper, one of the key exercises on the Russian physical training program. During ISS increment-3, TVIS unscheduled repairs took virtually all the training time. In search for TVIS backup, Russian and NASA engineers considered jointly Russian treadmill BD-1, originally designed for Russian "shuttle" Buran and accepted it as a suitable backup in case of complete TVIS failure. To enter into the "dialogue" with BD-1, i.e., to record and downlink training data, the treadmill speed indicator, a part of the treadmill stand, was replaced by PC.
Fakhouri, A; Kuperman, A
2014-01-01
The paper focuses on the quantitative analysis of Israeli Government's targets of 10% renewable energy penetration by 2020 and determining the desired methodology (models) for assessing the effects on the electricity market, addressing the fact that Israel is an electricity island. The main objective is to determine the influence of achieving the Government's goals for renewable energy penetration on the need for backup in the Israeli electricity system. This work presents the current situation of the Israeli electricity market and the study to be taken in order to assess the undesirable effects resulting from the intermittency of electricity generated by wind and solar power stations as well as presents some solutions to mitigating these phenomena. Future work will focus on a quantitative analysis of model runs and determine the amounts of backup required relative to the amount of installed capacity from renewable resources.
A hybrid data compression approach for online backup service
NASA Astrophysics Data System (ADS)
Wang, Hua; Zhou, Ke; Qin, MingKang
2009-08-01
With the popularity of Saas (Software as a service), backup service has becoming a hot topic of storage application. Due to the numerous backup users, how to reduce the massive data load is a key problem for system designer. Data compression provides a good solution. Traditional data compression application used to adopt a single method, which has limitations in some respects. For example data stream compression can only realize intra-file compression, de-duplication is used to eliminate inter-file redundant data, compression efficiency cannot meet the need of backup service software. This paper proposes a novel hybrid compression approach, which includes two levels: global compression and block compression. The former can eliminate redundant inter-file copies across different users, the latter adopts data stream compression technology to realize intra-file de-duplication. Several compressing algorithms were adopted to measure the compression ratio and CPU time. Adaptability using different algorithm in certain situation is also analyzed. The performance analysis shows that great improvement is made through the hybrid compression policy.
OJINO, Mayo; ISHII, Masami
2014-01-01
The radiation emergency medical system in Japan ceased to function as a result of the accident at the Fukushima Daiichi Nuclear Power Plant, which has commonly become known as the “Fukushima Accident.” In this paper, we review the reconstruction processes of the radiation emergency medical system in order of events and examine the ongoing challenges to overcoming deficiencies and reinforcing the system by reviewing relevant literature, including the official documents of the investigation committees of the National Diet of Japan, the Japanese government, and the Tokyo Electric Power Company, as well as technical papers written by the doctors involved in radiation emergency medical activities in Fukushima. Our review has revealed that the reconstruction was achieved in 6 stages from March 11 to July 1, 2011: (1) Re-establishment of an off-site center (March 13), (2) Re-establishment of a secondary radiation emergency hospital (March 14), (3) Reconstruction of the initial response system for radiation emergency care (April 2), (4) Reinforcement of the off-site center and stationing of disaster medical advisors at the off-site center (April 4), (5) Reinforcement of the medical care system and an increase in the number of hospitals for non-contaminated patients (From April 2 to June 23), and (6) Enhancement of the medical care system in the Fukushima Nuclear Power Plant and the construction of a new medical care system, involving both industrial medicine and emergency medicine (July 1). Medical resources such as voluntary efforts, academic societies, a local community medical system and university hospitals involved in medical care activities on 6 stages originally had not planned. In the future, radiation emergency medical systems should be evaluated with these 6 stages as a basis, in order to reinforce and enrich both the existing and backup systems so that minimal harm will come to nuclear power plant workers or evacuees and that they will receive proper care. This will involve creating a network of medical resources becoming involved across the country. PMID:25237278
Ojino, Mayo; Ishii, Masami
2014-02-01
The radiation emergency medical system in Japan ceased to function as a result of the accident at the Fukushima Daiichi Nuclear Power Plant, which has commonly become known as the "Fukushima Accident." In this paper, we review the reconstruction processes of the radiation emergency medical system in order of events and examine the ongoing challenges to overcoming deficiencies and reinforcing the system by reviewing relevant literature, including the official documents of the investigation committees of the National Diet of Japan, the Japanese government, and the Tokyo Electric Power Company, as well as technical papers written by the doctors involved in radiation emergency medical activities in Fukushima. Our review has revealed that the reconstruction was achieved in 6 stages from March 11 to July 1, 2011: (1) Re-establishment of an off-site center (March 13), (2) Re-establishment of a secondary radiation emergency hospital (March 14), (3) Reconstruction of the initial response system for radiation emergency care (April 2), (4) Reinforcement of the off-site center and stationing of disaster medical advisors at the off-site center (April 4), (5) Reinforcement of the medical care system and an increase in the number of hospitals for non-contaminated patients (From April 2 to June 23), and (6) Enhancement of the medical care system in the Fukushima Nuclear Power Plant and the construction of a new medical care system, involving both industrial medicine and emergency medicine (July 1). Medical resources such as voluntary efforts, academic societies, a local community medical system and university hospitals involved in medical care activities on 6 stages originally had not planned. In the future, radiation emergency medical systems should be evaluated with these 6 stages as a basis, in order to reinforce and enrich both the existing and backup systems so that minimal harm will come to nuclear power plant workers or evacuees and that they will receive proper care. This will involve creating a network of medical resources becoming involved across the country.
Assessment of hospital emergency management in the Beijing area.
Yantao, Xin
2011-06-01
In recent years, the number of public health emergencies has increased. Improving hospital emergency management is an important challenge. This is a pilot study intended to assess hospital emergency management in the Beijing area, make recommendations to government health authorities and hospital managers, and offer references for similar studies. This was an observational, cross-sectional survey. Forty-five hospitals in the Beijing area were selected randomly. A self-administered questionnaire was used as a data collection tool. It comprised of three sections: (1) Section A was the introduction; (2) Section B asked for the respondent's personal information; and (3) Section C comprised the major part of the questionnaire and was intended to gather information regarding the hospital's general emergency management situation. The survey response rate was 44%, accounting for 29% of total hospitals that the study targeted. No hospital had an established emergency management department or full-time staff for emergency management. A total of 15-45% of the hospitals had established a hospital emergency management committee, performed a vulnerability analysis, or evaluated emergency management regularly. Twenty-five percent of respondents thought that the local government health authority had established an integrated hospital incident command system. A total of 40%-55% of hospitals contracted with outside institutions for supplements, backup of key functional systems and professional support. After the occurrence of the 2003 severe acute respiratory syndrome (SARS) epidemic, Chinese hospital managers took many measures to improve hospital resilience. However, most of these efforts lacked the guidance of theories, concepts, principles, and methods. An integrated, standardized, operational hospital emergency management model has not been established. Although the survey response rate was relatively low, some clues for further study were discovered, and suggestions to the health authority for hospital emergency management improvement were revealed.
Crew-Aided Autonomous Navigation Project
NASA Technical Reports Server (NTRS)
Holt, Greg
2015-01-01
Manual capability to perform star/planet-limb sightings provides a cheap, simple, and robust backup navigation source for exploration missions independent from the ground. Sextant sightings from spacecraft were first exercised in Gemini and flew as the loss-of-communications backup for all Apollo missions. This study seeks to procure and characterize error sources of navigation-grade sextants for feasibility of taking star and planetary limb sightings from inside a spacecraft. A series of similar studies was performed in the early/mid-1960s in preparation for Apollo missions, and one goal of this study is to modernize and update those findings. This technique has the potential to deliver significant risk mitigation, validation, and backup to more complex low-TRL automated systems under development involving cameras.
Koenig, Kristi L
2003-01-01
The terrorist attacks of 11 September 2001 led to the largest US Government transformation since the formation of the Department of Defense following World War II. More than 22 different agencies, in whole or in part, and >170,000 employees were reorganized to form a new Cabinet-level Department of Homeland Security (DHS), with the primary mission to protect the American homeland. Legislation enacted in November 2002 transferred the entire Federal Emergency Management Agency and several Department of Health and Human Services (HHS) assets to DHS, including the Office of Emergency Response, and oversight for the National Disaster Medical System, Strategic National Stockpile, and Metropolitan Medical Response System. This created a potential separation of "health" and "medical" assets between the DHS and HHS. A subsequent presidential directive mandated the development of a National Incident Management System and an all-hazard National Response Plan. While no Department of Veterans Affairs (VA) assets were targeted for transfer, the VA remains the largest integrated healthcare system in the nation with important support roles in homeland security that complement its primary mission to provide care to veterans. The Emergency Management Strategic Healthcare Group (EMSHG) within the VA's medical component, the Veteran Health Administration (VHA), is the executive agent for the VA's Fourth Mission, emergency management. In addition to providing comprehensive emergency management services to the VA, the EMSHG coordinates medical back-up to the Department of Defense, and assists the public via the National Disaster Medical System and the National Response Plan. This article describes the VA's role in homeland security and disasters, and provides an overview of the ongoing organizational and operational changes introduced by the formation of the new DHS. Challenges and opportunities for public health are highlighted.
Accelerating Acceptance of Fuel Cell Backup Power Systems - Final Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Petrecky, James; Ashley, Christopher
2014-07-21
Since 2001, Plug Power has installed more than 800 stationary fuel cell systems worldwide. Plug Power’s prime power systems have produced approximately 6.5 million kilowatt hours of electricity and have accumulated more than 2.5 million operating hours. Intermittent, or backup, power products have been deployed with telecommunications carriers and government and utility customers in North and South America, Europe, the United Kingdom, Japan and South Africa. Some of the largest material handling operations in North America are currently using the company’s motive power units in fuel cell-powered forklifts for their warehouses, distribution centers and manufacturing facilities. The low-temperature GenSys fuelmore » cell system provides remote, off-grid and primary power where grid power is unreliable or nonexistent. Built reliable and designed rugged, low- temperature GenSys delivers continuous or backup power through even the most extreme conditions. Coupled with high-efficiency ratings, low-temperature GenSys reduces operating costs making it an economical solution for prime power requirements. Currently, field trials at telecommunication and industrial sites across the globe are proving the advantages of fuel cells—lower maintenance, fuel costs and emissions, as well as longer life—compared with traditional internal combustion engines.« less
Reducing Backups by Utilizing DMF
NASA Technical Reports Server (NTRS)
Cardo, Nicholas P.; Woodrow, Thomas (Technical Monitor)
1994-01-01
Although a filesystem may be migratable, for a period of time the data blocks are on disk only. When performing system dumps, these data blocks are backed up to tape. If the data blocks are offline or dual resident, then only the inode is backed up. If all online files are made dual resident prior to performing system dumps, the dump time and the amount of resources required can be significantly reduced. The High Speed Processors group at the Numerical Aerodynamics Simulation (NAS) Facility at NASA Ames Research Center developed a tool to make all online files dual resident. The result is that a file whose data blocks are on DMF tape and still assigned to the original inode. Our 150GB filesystem used to take 8 to 12 hours to backup and used 50 to 60 tapes. Now the backup is typically under 10 tapes and completes in under 2 hours. This paper discusses this new tool and advantages gained by using it.
Fail-over file transfer process
NASA Technical Reports Server (NTRS)
Semancik, Susan K. (Inventor); Conger, Annette M. (Inventor)
2005-01-01
The present invention provides a fail-over file transfer process to handle data file transfer when the transfer is unsuccessful in order to avoid unnecessary network congestion and enhance reliability in an automated data file transfer system. If a file cannot be delivered after attempting to send the file to a receiver up to a preset number of times, and the receiver has indicated the availability of other backup receiving locations, then the file delivery is automatically attempted to one of the backup receiving locations up to the preset number of times. Failure of the file transfer to one of the backup receiving locations results in a failure notification being sent to the receiver, and the receiver may retrieve the file from the location indicated in the failure notification when ready.
STS-46 crewmembers during water egress training in JSC's WETF Bldg 29
NASA Technical Reports Server (NTRS)
1992-01-01
STS-46 Atlantis, Orbiter Vehicle (OV) 104, European Space Agency (ESA) Mission Specialist (MS) Claude Nicollier (left) and backup Italian Payload Specialist Umberto Guidoni, seated at the pool's side, relax before participating in a launch emergency egress (bailout) simulation in JSC's Weightless Environment Training Facility (WETF) Bldg 29. The two participants are wearing launch and entry suits (LESs) during the pretest briefing.
First evidence for "The backup plan paradox".
Napolitano, Christopher M; Freund, Alexandra M
2017-08-01
This research is a first test of the backup plan paradox. We hypothesized that investing in a backup plan may facilitate the conditions that it was developed to address: Plan A's insufficiency. Five studies provide initial, primarily correlative support for the undermining effect of investing in a backup plan. Study 1 (n= 160) demonstrated that the more participants perceived they had invested in developing a backup plan (preparing a "crib sheet"), the more likely they were to use it, although greater investments were unrelated to backup plan utility. Studies 2-4 used a simulated negotiation task. Study 2 (n = 247) demonstrated that when goal-relevant resources are limited, investing in developing backup plans and perceiving them as highly instrumental can decrease goal performance through the indirect effect of increased means replacing. Study 3 (n = 248) replicated this effect when goal-relevant resources were plentiful. Study 4 (n = 204) used an experimental variant of the simulated negotiation task and demonstrated that simply having a backup plan is not detrimental, but perceiving backup plans to be highly instrumental decreased goal performance, again through the indirect effect of increased means replacing. Study 5 (n = 160) replicated findings from Studies 1-4 using a lab-based motor task (throwing a ball). Together, these results provide first evidence that backup plans can introduce costs that may jeopardize goal performance. (PsycINFO Database Record (c) 2017 APA, all rights reserved).
NASA Astrophysics Data System (ADS)
Hamidi, A.; Grossberg, M.; Khanbilvardi, R.
2016-12-01
Flood response in an urban area is the product of interactions of spatially and temporally varying rainfall and infrastructures. In urban areas, however, the complex sub-surface networks of tunnels, waste and storm water drainage systems are often inaccessible, pose challenges for modeling and prediction of the drainage infrastructure performance. The increased availability of open data in cities is an emerging information asset for a better understanding of the dynamics of urban water drainage infrastructure. This includes crowd sourced data and community reporting. A well-known source of this type of data is the non-emergency hotline "311" which is available in many US cities, and may contain information pertaining to the performance of physical facilities, condition of the environment, or residents' experience, comfort and well-being. In this study, seven years of New York City 311 (NYC311) call during 2010-2016 is employed, as an alternative approach for identifying the areas of the city most prone to sewer back up flooding. These zones are compared with the hydrologic analysis of runoff flooding zones to provide a predictive model for the City. The proposed methodology is an example of urban system phenomenology using crowd sourced, open data. A novel algorithm for calculating the spatial distribution of flooding complaints across NYC's five boroughs is presented in this study. In this approach, the features that represent reporting bias are separated from those that relate to actual infrastructure system performance. The sewer backup results are assessed with the spatial distribution of runoff in NYC during 2010-2016. With advances in radar technologies, a high spatial-temporal resolution data set for precipitation is available for most of the United States that can be implemented in hydrologic analysis of dense urban environments. High resolution gridded Stage IV radar rainfall data along with the high resolution spatially distributed land cover data are employed to investigate the urban pluvial flooding. The monthly results of excess runoff are compared with the sewer backup in NYC to build a predictive model of flood zones according to the 311 phone calls.
Evaluation of Urban Drainage Infrastructure: New York City Case Study
NASA Astrophysics Data System (ADS)
Hamidi, A.; Grossberg, M.; Khanbilvardi, R.
2017-12-01
Flood response in an urban area is the product of interactions of spatially and temporally varying rainfall and infrastructures. In urban areas, however, the complex sub-surface networks of tunnels, waste and storm water drainage systems are often inaccessible, pose challenges for modeling and prediction of the drainage infrastructure performance. The increased availability of open data in cities is an emerging information asset for a better understanding of the dynamics of urban water drainage infrastructure. This includes crowd sourced data and community reporting. A well-known source of this type of data is the non-emergency hotline "311" which is available in many US cities, and may contain information pertaining to the performance of physical facilities, condition of the environment, or residents' experience, comfort and well-being. In this study, seven years of New York City 311 (NYC311) call during 2010-2016 is employed, as an alternative approach for identifying the areas of the city most prone to sewer back up flooding. These zones are compared with the hydrologic analysis of runoff flooding zones to provide a predictive model for the City. The proposed methodology is an example of urban system phenomenology using crowd sourced, open data. A novel algorithm for calculating the spatial distribution of flooding complaints across NYC's five boroughs is presented in this study. In this approach, the features that represent reporting bias are separated from those that relate to actual infrastructure system performance. The sewer backup results are assessed with the spatial distribution of runoff in NYC during 2010-2016. With advances in radar technologies, a high spatial-temporal resolution data set for precipitation is available for most of the United States that can be implemented in hydrologic analysis of dense urban environments. High resolution gridded Stage IV radar rainfall data along with the high resolution spatially distributed land cover data are employed to investigate the urban pluvial flooding. The monthly results of excess runoff are compared with the sewer backup in NYC to build a predictive model of flood zones according to the 311 phone calls.
Sleep Better at Night...Back Up Your Data.
ERIC Educational Resources Information Center
Smith, Russell
1996-01-01
Discusses the need to back up computer files, and describes the technological evolution of back-up methods. Reviews tape drive and external hard drive back-up products offered by computer companies and presents back-up strategies to use with all back-up methods. A sidebar lists information on the reviewed products. (JMV)
Gemini 8 prime and backup crews during press conference
1966-02-26
S66-24380 (26 Feb. 1966) --- Gemini-8 prime and backup crews during press conference. Left to right are astronauts David R. Scott, prime crew pilot; Neil A. Armstrong, prime crew command pilot; Charles Conrad Jr., backup crew command pilot; and Richard F. Gordon Jr., backup crew pilot. Photo credit: NASA
The role of ground water in water-supply emergency planning
NASA Astrophysics Data System (ADS)
Reichard, E. G.; Li, Z.; Hermans, C.
2008-12-01
Catastrophic events, such as earthquakes or floods, can result in water-supply disruptions. Such disruptions can cause large economic losses and pose threats to public health. Water managers seek to develop cost- effective strategies for reducing these risks and ensuring water security. In many areas, ground water can play an important role in such water-supply emergency planning. We present a probabilistic framework for estimating the hydraulic impacts and associated costs of using ground water as a backup supply in the event of a disruption in imported-water deliveries. We also estimate the benefits of ground-water management strategies, such as artificial recharge, in terms of reduced costs of responding to water-supply emergencies. The magnitude of these benefits will depend on the expected severity and duration of the imported-water disruption, the functioning of the hydrogeologic system, and economic parameters. We apply the framework to address water-supply emergency planning in the Los Angeles area. A simulation model is used to generate response functions, which relate emergency ground-water pumpage to potential adverse effects, such as increased pumping lifts, subsidence, and seawater intrusion. These response functions are incorporated into a Monte Carlo analysis, along with cost coefficients and information on the probable severity of the disruption. Disruption severity is represented by a probability distribution, which can be elicited from water managers. In the example, the primary emergency-related benefits of artificial recharge are reductions in potential subsidence costs. The framework could be extended to consider additional engineering factors (e.g., well capacities and integrity of local distribution systems), institutional arrangements, and regulatory requirements.
Doty, D W; McInnis, T; Paul, G L
1974-01-01
Response-cost procedures within a token economy with extremely regressed residents excluded many residents from access to positive reinforcement. Procedures allowing residents to "purchase eligibility" to obtain backup reinforcers through contingent payment on standing fines, combined with proportional fine payoff schedules contingent upon time without new fines, increased payment on fines, reduced incidence of new fines, and increased utilization of backup reinforcers. These modifications removed adverse side effects while retaining the benefits associated with response costs. Failures or adverse effects of elements of token systems should not occasion abandonment of token economies, but rather encourage their continual evaluation and modification.
Techno-economic assessment of a hybrid solar receiver and combustor
NASA Astrophysics Data System (ADS)
Lim, Jin Han; Nathan, Graham; Dally, Bassam; Chinnici, Alfonso
2016-05-01
A techno-economic analysis is performed to compare two different configurations of hybrid solar thermal systems with fossil fuel backup to provide continuous electricity output. The assessment compares a Hybrid Solar Receiver Combustor (HSRC), in which the functions of a solar cavity receiver and a combustor are integrated into a single device with a reference conventional solar thermal system using a regular solar cavity receiver with a backup boiler, termed the Solar Gas Hybrid (SGH). The benefits of the integration is assessed by varying the size of the storage capacity and heliostat field while maintaining the same overall thermal input to the power block.
NASA Technical Reports Server (NTRS)
Larson, R. R.
1986-01-01
The wing on the NASA F-111 transonic aircraft technology airplane was modified to provide flexible leading and trailing edge flaps. This wing is known as the mission adaptive wing (MAW) because aerodynamic efficiency can be maintained at all speeds. Unlike a conventional wing, the MAW has no spoilers, external flap hinges, or fairings to break the smooth contour. The leading edge flaps and three-segment trailing edge flaps are controlled by a redundant fly-by-wire control system that features a dual digital primary system architecture providing roll and symmetric commands to the MAW control surfaces. A segregated analog backup system is provided in the event of a primary system failure. This paper discusses the design, development, testing, qualification, and flight test experience of the MAW primary and backup flight control systems.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bolton, N. E.; Ketchen, E. E.; Porter, W. E.
For large industrial and research operations, maintaining reasonable control of all toxic materials used in their operations can be a formidable task. A system utilizing cards has been developed that serves a dual purpose, informing the user regarding hazards of a particular material and also facilitating appropriate workplace surveillance during its use. Selected data, including threshold limit values, routes of absorption, symptoms of exposure, chronic effects, and emergency first-aid procedures, are printed on the card. A portion of the card contains the label that the user detaches and affixes to the container. This label classifies the material according to flammability,more » toxicity, reactivity, and special properties on a 0 through 4 hazard rating system. This report describes the development and use of such cards, contains the associated Toxic Material Data Sheets that provide full backup data for the labels, and furnishes a glossary of biomedical terms used in the Data Sheets.« less
Rockwell, Kimberly Lovett; Gilroy, Alexis
2018-03-12
Telemedicine is a growing and important platform for medical delivery in the emergency department. Emergency telemedicine outlays often confront and conflict with important federal healthcare regulations. Because of this, academic medical centers, critical access hospitals, and other providers interested in implementing emergency telemedicine have often delayed or forgone such services due to reasonable fears of falling out of compliance with regulatory restrictions imposed by the Emergency Medical Treatment and Labor Act ("EMTALA"). This article offers insights into methods for implementing emergency telemedicine services while maintaining EMTALA compliance. Critical analysis of EMTALA and its attendant regulations. The primary means of ensuring EMTALA compliance while implementing emergency telemedicine programs include incorporating critical clinical details into the services contracts and implementing robust written policies that anticipate division of labor issues, the need for backup coverage, triaging, patient transfer protocols, and credentialing issues. With adequate up-front due diligence and meaningful contracting, hospitals and telemedicine providers can avoid common EMTALA liability pitfalls.
Operation and maintenance of the Sol-Dance Building solar system. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gaultney, J.R.
1980-07-29
A 16,400 square foot general office facility has its primary heating provided by a flat plate solar system using hydronic storage and water-to-air transfer coils for distribution. Backup heat is provided by 10 individually controlled air source heat pumps ranging from 3 tons to 5 tons in capacity. These heat pumps also contain electric resistive elements for use during extremely low ambient temperatures. Cooling is also provided by the heat pumps. Each of the two buildings contains a separate domestic hot water system. Primary heat is provided by a closed loop solar unit with electric elements providing backup heat. Amore » 10,000 gallon black steel water tank provides heat storage.« less
Characteristics of Operational Space Weather Forecasting: Observations and Models
NASA Astrophysics Data System (ADS)
Berger, Thomas; Viereck, Rodney; Singer, Howard; Onsager, Terry; Biesecker, Doug; Rutledge, Robert; Hill, Steven; Akmaev, Rashid; Milward, George; Fuller-Rowell, Tim
2015-04-01
In contrast to research observations, models and ground support systems, operational systems are characterized by real-time data streams and run schedules, with redundant backup systems for most elements of the system. We review the characteristics of operational space weather forecasting, concentrating on the key aspects of ground- and space-based observations that feed models of the coupled Sun-Earth system at the NOAA/Space Weather Prediction Center (SWPC). Building on the infrastructure of the National Weather Service, SWPC is working toward a fully operational system based on the GOES weather satellite system (constant real-time operation with back-up satellites), the newly launched DSCOVR satellite at L1 (constant real-time data network with AFSCN backup), and operational models of the heliosphere, magnetosphere, and ionosphere/thermosphere/mesophere systems run on the Weather and Climate Operational Super-computing System (WCOSS), one of the worlds largest and fastest operational computer systems that will be upgraded to a dual 2.5 Pflop system in 2016. We review plans for further operational space weather observing platforms being developed in the context of the Space Weather Operations Research and Mitigation (SWORM) task force in the Office of Science and Technology Policy (OSTP) at the White House. We also review the current operational model developments at SWPC, concentrating on the differences between the research codes and the modified real-time versions that must run with zero fault tolerance on the WCOSS systems. Understanding the characteristics and needs of the operational forecasting community is key to producing research into the coupled Sun-Earth system with maximal societal benefit.
The amino acid's backup bone - storage solutions for proteomics facilities.
Meckel, Hagen; Stephan, Christian; Bunse, Christian; Krafzik, Michael; Reher, Christopher; Kohl, Michael; Meyer, Helmut Erich; Eisenacher, Martin
2014-01-01
Proteomics methods, especially high-throughput mass spectrometry analysis have been continually developed and improved over the years. The analysis of complex biological samples produces large volumes of raw data. Data storage and recovery management pose substantial challenges to biomedical or proteomic facilities regarding backup and archiving concepts as well as hardware requirements. In this article we describe differences between the terms backup and archive with regard to manual and automatic approaches. We also introduce different storage concepts and technologies from transportable media to professional solutions such as redundant array of independent disks (RAID) systems, network attached storages (NAS) and storage area network (SAN). Moreover, we present a software solution, which we developed for the purpose of long-term preservation of large mass spectrometry raw data files on an object storage device (OSD) archiving system. Finally, advantages, disadvantages, and experiences from routine operations of the presented concepts and technologies are evaluated and discussed. This article is part of a Special Issue entitled: Computational Proteomics in the Post-Identification Era. Guest Editors: Martin Eisenacher and Christian Stephan. Copyright © 2013. Published by Elsevier B.V.
Simulating cloud environment for HIS backup using secret sharing.
Kuroda, Tomohiro; Kimura, Eizen; Matsumura, Yasushi; Yamashita, Yoshinori; Hiramatsu, Haruhiko; Kume, Naoto
2013-01-01
In the face of a disaster hospitals are expected to be able to continue providing efficient and high-quality care to patients. It is therefore crucial for hospitals to develop business continuity plans (BCPs) that identify their vulnerabilities, and prepare procedures to overcome them. A key aspect of most hospitals' BCPs is creating the backup of the hospital information system (HIS) data at multiple remote sites. However, the need to keep the data confidential dramatically increases the costs of making such backups. Secret sharing is a method to split an original secret message so that individual pieces are meaningless, but putting sufficient number of pieces together reveals the original message. It allows creation of pseudo-redundant arrays of independent disks for privacy-sensitive data over the Internet. We developed a secret sharing environment for StarBED, a large-scale network experiment environment, and evaluated its potential and performance during disaster recovery. Simulation results showed that the entire main HIS database of Kyoto University Hospital could be retrieved within three days even if one of the distributed storage systems crashed during a disaster.
NASA Technical Reports Server (NTRS)
Jansen, Mark; Montague, Gerald; Provenza, Andrew; Palazzolo, Alan
2004-01-01
Closed loop operation of a single, high temperature magnetic radial bearing to 30,000 RPM (2.25 million DN) and 540 C (1000 F) is discussed. Also, high temperature, fault tolerant operation for the three axis system is examined. A novel, hydrostatic backup bearing system was employed to attain high speed, high temperature, lubrication free support of the entire rotor system. The hydrostatic bearings were made of a high lubricity material and acted as journal-type backup bearings. New, high temperature displacement sensors were successfully employed to monitor shaft position throughout the entire temperature range and are described in this paper. Control of the system was accomplished through a stand alone, high speed computer controller and it was used to run both the fault-tolerant PID and active vibration control algorithms.
Gostimskaya, Irina; Grant, Chris M.
2016-01-01
Glutathione is an abundant, low-molecular-weight tripeptide whose biological importance is dependent upon its redox-active free sulphydryl moiety. Its role as the main determinant of thiol-redox control has been challenged such that it has been proposed to play a crucial role in iron–sulphur clusters maturation, and only a minor role in thiol redox regulation, predominantly as a back-up system for the cytoplasmic thioredoxin system. Here, we have tested the importance of mitochondrial glutathione in thiol-redox regulation. Glutathione reductase (Glr1) is an oxidoreductase which converts oxidized glutathione to its reduced form. Yeast Glr1 localizes to both the cytosol and mitochondria and we have used a Glr1M1L mutant that is constitutively localized to the cytosol to test the requirement for mitochondrial Glr1. We show that the loss of mitochondrial Glr1 specifically accounts for oxidant sensitivity of a glr1 mutant. Loss of mitochondrial Glr1 does not influence iron–sulphur cluster maturation and we have used targeted roGFP2 fluorescent probes to show that oxidant sensitivity is linked to an altered redox environment. Our data indicate mitochondrial glutathione is crucial for mitochondrial thiol-redox regulation, and the mitochondrial thioredoxin system provides a back-up system, but cannot bear the redox load of the mitochondria on its own. PMID:26898146
Fakhouri, A.; Kuperman, A.
2014-01-01
The paper focuses on the quantitative analysis of Israeli Government's targets of 10% renewable energy penetration by 2020 and determining the desired methodology (models) for assessing the effects on the electricity market, addressing the fact that Israel is an electricity island. The main objective is to determine the influence of achieving the Government's goals for renewable energy penetration on the need for backup in the Israeli electricity system. This work presents the current situation of the Israeli electricity market and the study to be taken in order to assess the undesirable effects resulting from the intermittency of electricity generated by wind and solar power stations as well as presents some solutions to mitigating these phenomena. Future work will focus on a quantitative analysis of model runs and determine the amounts of backup required relative to the amount of installed capacity from renewable resources. PMID:24624044
NASA Astrophysics Data System (ADS)
Kumar, Shailesh; Rao, Shrisha
This paper studies a phenomenon called failover, and shows that this phenomenon (in particular, stateless failover) can be modeled by Game of Life cellular automata. This is the first time that this sophisticated real-life system behavior has been modeled in abstract terms. A cellular automata (CA) configuration is constructed that exhibits emergent failover. The configuration is based on standard Game of Life rules. Gliders and glider-guns form the core messaging structure in the configuration. The blinker is represented as the basic computational unit, and it is shown how it can be recreated in case of a failure. Stateless failover using the primary-backup mechanism is demonstrated. The details of the CA components used in the configuration and its working are described, and a simulation of the complete configuration is also presented.
Al-Shaqsi, Sultan; Gauld, Robin; Lovell, Sarah; McBride, David; Al-Kashmiri, Ammar; Al-Harthy, Abdullah
2013-03-15
Disasters are a growing global phenomenon. New Zealand has suffered several major disasters in recent times. The state of healthcare disaster preparedness in New Zealand prior to the Canterbury earthquakes is not well documented. To investigate the challenges of the New Zealand healthcare disaster preparedness prior to the Canterbury earthquakes. Semi-structured interviews with emergency planners in all the District Health Boards (DHBs) in New Zealand in the period between January and March 2010. The interview protocol revolved around the domains of emergency planning adopted by the World Health Organization. Seventeen interviews were conducted. The main themes included disinterest of clinical personnel in emergency planning, the need for communication backup, the integration of private services in disaster preparedness, the value of volunteers, the requirement for regular disaster training, and the need to enhance surge capability of the New Zealand healthcare system to respond to disasters. Prior to the Canterbury earthquakes, healthcare disaster preparedness faced multiple challenges. Despite these challenges, New Zealand's healthcare response was adequate. Future preparedness has to consider the lessons learnt from the 2011 earthquakes to improve healthcare disaster planning in New Zealand.
1987-06-01
de- mands unexpected or inordinate amounts of time; (2) the prevalence of child - care problems, especially finding arrangements flexible enough to...associated with frequent relocations, especially the need to reestablish the netwqrk of socia] and child -care supports that enable single parents...most concern to single parents include time pressures, daily child -care arrangements, back-up and emergency supports for children, and frequent
Apollo Operations Handbook Lunar Module (LM 11 and Subsequent) Vol. 2 Operational Procedures
NASA Technical Reports Server (NTRS)
1971-01-01
The Apollo Operations Handbook (AOH) is the primary means of documenting LM descriptions and procedures. The AOH is published in two separately bound volumes. This information is useful in support of program management, engineering, test, flight simulation, and real time flight support efforts. This volume contains crew operational procedures: normal, backup, abort, malfunction, and emergency. These procedures define the sequence of actions necessary for safe and efficient subsystem operation.
Radappertized Meats for Aerospace Meals
1981-06-01
and canned bread made from irradiated wheat flour were used as emergency back-up foods in Skylab III. In response to a NASA request for foods for the...tt a,- /_ j .3 LIST OF TABLES PUge 1. Test Results of Vacuum Packaged Irradiated 10 Food Samples 2. Chemical Composition of Irradiated Food Samples...55 g Sodium nitrite .. ........ 1 g *Pickling spice mixture . . .... .... . 340 g (dry) The pumped briskets were stored at 30 C for 48 hours in
Gemini 7 backup crew seen in white room during Gemini 7 simulation activity
1965-11-27
S65-61837 (27 Nov. 1965) --- The Gemini-7 backup crew seen in the White Room atop Pad 19 during Gemini-7 simulation flight activity. McDonnell Aircraft Corporation technicians assist in the exercise. Astronaut Edward H. White II (in foreground) is the Gemini-7 backup crew command pilot; and astronaut Michael Collins (right background) is the backup crew pilot. Photo credit: NASA
Apollo 16 prime and backup crewmen during geological field trip in New Mexico
1971-09-09
Dr. Lee Silver (pointing foregroung), California Institute of Technology, calls a geological feature near Taos, New Mexico, to the attention of Apollo 16 prime and backup crewmen during a geological field trip. The crewmen, from left to right, are Astronauts Charles M. Duke Jr., lunar module pilot; Fred W. Haise Jr., backup commander; Edgar D. Mitchell, backup Lunar Module pilot; and John W. Young, commander.
Birth control pills - progestin only
... pregnant right away. When to Use a Backup Method Use a backup method of birth control, such as a condom, diaphragm, ... body may not absorb it. Use a backup method of birth control, and call your provider. You ...
Birth control pills - combination
... or mood swings. When to Use a Backup Method Use a backup method of birth control, such as condom, diaphragm, or ... body may not absorb it. Use a backup method of birth control for the rest of that ...
Data processing for water monitoring system
NASA Technical Reports Server (NTRS)
Monford, L.; Linton, A. T.
1978-01-01
Water monitoring data acquisition system is structured about central computer that controls sampling and sensor operation, and analyzes and displays data in real time. Unit is essentially separated into two systems: computer system, and hard wire backup system which may function separately or with computer.
100-Lb(f) LO2/LCH4 Reaction Control Engine Technology Development for Future Space Vehicles
NASA Technical Reports Server (NTRS)
Robinson, Philip J.; Veith, Eric M.; Hurlbert, Eric A.; Jimenez, Rafael; Smith, Timothy D.
2008-01-01
The National Aeronautics and Space Administration (NASA) has identified liquid oxygen (LO2)/liquid methane (LCH4) propulsion systems as promising options for some future space vehicles. NASA issued a contract to Aerojet to develop a 100-lbf (445 N) LO2/LCH4 Reaction Control Engine (RCE) aimed at reducing the risk of utilizing a cryogenic reaction control system (RCS) on a space vehicle. Aerojet utilized innovative design solutions to develop an RCE that can ignite reliably over a broad range of inlet temperatures, perform short minimum impulse bits (MIB) at small electrical pulse widths (EPW), and produce excellent specific impulse (Isp) across a range of engine mixture ratios (MR). These design innovations also provide a start transient with a benign MR, ensuring good thrust chamber compatibility and long life. In addition, this RCE can successfully operate at MRs associated with main engines, enabling the RCE to provide emergency backup propulsion to minimize vehicle propellant load and overall system mass.
100-LBF LO2/LCH4 - Reaction Control Engine Technology Development for Future Space Vehicles
NASA Technical Reports Server (NTRS)
Robinson, Philip J.; Veith, Eric M.; Hurlbert, Eric A.; Jimenez, Rafael; Smith, Timothy D.
2008-01-01
The National Aeronautics and Space Administration (NASA) has identified liquid oxygen (LO2)/liquid methane (LCH4) propulsion systems as promising options for some future space vehicles. NASA issued a contract to Aerojet to develop a 100-lbf (445 N) LO2/LCH4 Reaction Control Engine (RCE) aimed at reducing the risk of utilizing a cryogenic reaction control system (RCS) on a space vehicle. Aerojet utilized innovative design solutions to develop an RCE that can ignite reliably over a broad range of inlet temperatures, perform short minimum impulse bits (MIB) at small electrical pulse widths (EPW), and produce excellent specific impulse (Isp) across a range of engine mixture ratios (MR). These design innovations also provide a start transient with a benign MR, ensuring good thrust chamber compatibility and long life. In addition, this RCE can successfully operate at MRs associated with main engines, enabling the RCE to provide emergency backup propulsion to minimize vehicle propellant load and overall system mass.
NASA Technical Reports Server (NTRS)
Milder, G.
1975-01-01
The current work presents an overview of the Viking 1975 environmental testing from an engineering standpoint. An extremely large vibration test fixture had to be designed, analyzed, and integrated into a test setup that employed hydrostatic bearings in a new fashion. A vibration control system was also required that would allow for thirty-six channels of sine-wave peak select control from acceleration, force-of-strain transducers. In addition, some 68 channels of peak limiting shutdown capability were needed for backup and monitoring of other data during the forced vibration test. Pretesting included analyses of the fixture design, overturning moment, control system capabilities, and response of the entire spacecraft/fixture/exciter system to the test environment. Closed-loop control for acoustic testing was a necessity due to the fact that the Viking spacecraft took up a major portion of the volume of the 10,000 cu ft chamber. The spacecraft emerged from testing undamaged.
Integrated Neural Flight and Propulsion Control System
NASA Technical Reports Server (NTRS)
Kaneshige, John; Gundy-Burlet, Karen; Norvig, Peter (Technical Monitor)
2001-01-01
This paper describes an integrated neural flight and propulsion control system. which uses a neural network based approach for applying alternate sources of control power in the presence of damage or failures. Under normal operating conditions, the system utilizes conventional flight control surfaces. Neural networks are used to provide consistent handling qualities across flight conditions and for different aircraft configurations. Under damage or failure conditions, the system may utilize unconventional flight control surface allocations, along with integrated propulsion control, when additional control power is necessary for achieving desired flight control performance. In this case, neural networks are used to adapt to changes in aircraft dynamics and control allocation schemes. Of significant importance here is the fact that this system can operate without emergency or backup flight control mode operations. An additional advantage is that this system can utilize, but does not require, fault detection and isolation information or explicit parameter identification. Piloted simulation studies were performed on a commercial transport aircraft simulator. Subjects included both NASA test pilots and commercial airline crews. Results demonstrate the potential for improving handing qualities and significantly increasing survivability rates under various simulated failure conditions.
The Anaesthesia Gas Supply System
Das, Sabyasachi; Chattopadhyay, Subhrajyoti; Bose, Payel
2013-01-01
The anaesthesia gas supply system is designed to provide a safe, cost-effective and convenient system for the delivery of medical gases at the point of-use. The doctrine of the anaesthesia gas supply system is based on four essential principles: Identity, continuity, adequacy and quality. Knowledge about gas supply system is an integral component of safe anaesthetic practice. Mishaps involving the malfunction or misuse of medical gas supply to operating theatres have cost many lives. The medical gases used in anaesthesia and intensive care are oxygen, nitrous oxide, medical air, entonox, carbon dioxide and heliox. Oxygen is one of the most widely used gases for life-support and respiratory therapy besides anaesthetic procedures. In this article, an effort is made to describe the production, storage and delivery of anaesthetic gases. The design of anaesthesia equipment must take into account the local conditions such as climate, demand and power supply. The operational policy of the gas supply system should have a backup plan to cater to the emergency need of the hospital, in the event of the loss of the primary source of supply. PMID:24249882
A corporate treasurer toolkit to ensure fund delivery in disaster zones.
Parandeh, Sassan Cyrus
In a disaster situation, the corporate treasury department of an organisation is also responsible for ensuring business continuity. The treasury department's key role would be to ensure that vendors, suppliers and employees are adequately remunerated and that operations do not seize due to a lack of working capital. Treasury practitioners concerned with business continuity have traditionally focused on three mainstay aspects of the initiative: (1) creating virtual or remote treasury offices; (2) training key backup staff on emergency procedures; (3) maintaining power and telecommunication connectivity with their cash concentration bank to guarantee treasury is able to transmit funding instructions to them. This paper aims to take business continuity measures for corporate treasury departments to a higher level of preparedness by asking one critical question: 'What will happen if the cash concentration bank or the entire banking system of a country in which a company has operations collapses?' Rarely have treasury professionals contemplated such a cataclysmic scenario. This paper aims to (1) validate that banking system failures are common, (2) rationalise why treasury practitioners need to devise contingency funding strategies outside of the banking system and (3) offer some viable alternatives to commercial banks. In this regard the author will draw from the experience of international non-governmental organisations that routinely respond to and operate in cataclysmic emergencies.
Backup agreements with penalty scheme under supply disruptions
NASA Astrophysics Data System (ADS)
Hou, Jing; Zhao, Lindu
2012-05-01
This article considers a supply chain for a single product involving one retailer and two independent suppliers, when the main supplier might fail to supply the products, the backup supplier can always supply the products at a higher price. The retailer could use the backup supplier as a regular provider or a stand-by source by reserving some products at the supplier. A backup agreement with penalty scheme is constructed between the retailer and the backup supplier to mitigate the supply disruptions and the demand uncertainty. The expected profit functions and the optimal decisions of the two players are derived through a sequential optimisation process. Then, the sensitivity of two players' expected profits to various input factors is examined through numerical examples. The impacts of the disruption probability and the demand uncertainty on the backup agreement are also investigated, which could provide guideline for how to use each sourcing method.
The near-source impacts of diesel backup generators in urban environments
NASA Astrophysics Data System (ADS)
Tong, Zheming; Zhang, K. Max
2015-05-01
Distributed power generation, located close to consumers, plays an important role in the current and future power systems. However, its near-source impacts in complex urban environments are not well understood. In this paper, we focused on diesel backup generators that participate in demand response (DR) programs. We first improved the micro-environmental air quality simulations by employing a meteorology processor, AERMET, to generate site-specific boundary layer parameters for the Large Eddy Simulation (LES) modeling. The modeling structure was then incorporated into the CTAG model to evaluate the environmental impacts of diesel backup generators in near-source microenvironments. We found that the presence of either tall upwind or downwind building can deteriorate the air quality in the near-stack street canyons, largely due to the recirculation zones generated by the tall buildings, reducing the near-stack dispersion. Decreasing exhaust momentum ratio (stack exit velocity/ambient wind velocity) draws more exhaust into the recirculation zone, and reduces the effective stack height, which results in elevated near-ground concentrations inside downwind street canyons. The near-ground PM2.5 concentration for the worst scenarios could well exceed 100 μg m-3, posing potential health risk to people living and working nearby. In general, older diesel backup generators (i.e., Tier 1, 2 or older) without the up-to-date emission control may significantly increase the pollutant concentration in the near-source street canyons if participating in DR programs. Even generators that comply with Tier-4 standards could lead to PM hotspots if their stacks are next to tall buildings. Our study implies that the siting of diesel backup generators stacks should consider not only the interactions of fresh air intake and exhaust outlet for the building housing the backup generators, but also the dispersion of exhaust plumes in the surrounding environment.
A Two-Wheel Observing Mode for the MAP Spacecraft
NASA Technical Reports Server (NTRS)
Starin, Scott R.; ODonnell, James R., Jr.
2001-01-01
The Microwave Anisotropy Probe (MAP) is a follow-on to the Differential Microwave Radiometer (DMR) instrument on the Cosmic Background Explorer (COBE). Due to the MAP project's limited mass, power, and budget, a traditional reliability concept including fully redundant components was not feasible. The MAP design employs selective hardware redundancy, along with backup software modes and algorithms, to improve the odds of mission success. This paper describes the effort to develop a backup control mode, known as Observing II, that will allow the MAP science mission to continue in the event of a failure of one of its three reaction wheel assemblies. This backup science mode requires a change from MAP's nominal zero-momentum control system to a momentum-bias system. In this system, existing thruster-based control modes are used to establish a momentum bias about the sun line sufficient to spin the spacecraft up to the desired scan rate. Natural spacecraft dynamics exhibits spin and nutation similar to the nominal MAP science mode with different relative rotation rates, so the two reaction wheels are used to establish and maintain the desired nutation angle from the sun line. Detailed descriptions of the ObservingII control algorithm and simulation results will be presented, along with the operational considerations of performing the rest of MAP's necessary functions with only two wheels.
Electricity by intermittent sources: An analysis based on the German situation 2012
NASA Astrophysics Data System (ADS)
Wagner, Friedrich
2014-02-01
The 2012 data of the German load, the on- and offshore and the photo-voltaic energy production are used and scaled to the limit of supplying the annual demand (100% case). The reference mix of the renewable energy (RE) forms is selected such that the remaining back-up energy is minimised. For the 100% case, the RE power installation has to be about 3 times the present peak load. The back-up system can be reduced by 12% in this case. The surplus energy corresponds to 26% of the demand. The back-up system and more so the grid must be able to cope with large power excursions. All components of the electricity supply system operate at low capacity factors. Large-scale storage can hardly be motivated by the effort to further reduce CO2 emission. Demand-side management will intensify the present periods of high economic activities. Its rigorous implementation will expand the economic activities into the weekends. On the basis of a simple criterion, the increase of periods with negative electricity prices in Germany is assessed. It will be difficult with RE to meet the low CO2 emission factors which characterise those European Countries which produce electricity mostly by nuclear and hydro power.
Strong, G.H.; Faught, M.L.
1963-12-24
A device for safety rod counting in a nuclear reactor is described. A Wheatstone bridge circuit is adapted to prevent de-energizing the hopper coils of a ball backup system if safety rods, sufficient in total control effect, properly enter the reactor core to effect shut down. A plurality of resistances form one arm of the bridge, each resistance being associated with a particular safety rod and weighted in value according to the control effect of the particular safety rod. Switching means are used to switch each of the resistances in and out of the bridge circuit responsive to the presence of a particular safety rod in its effective position in the reactor core and responsive to the attainment of a predetermined velocity by a particular safety rod enroute to its effective position. The bridge is unbalanced in one direction during normal reactor operation prior to the generation of a scram signal and the switching means and resistances are adapted to unbalance the bridge in the opposite direction if the safety rods produce a predetermined amount of control effect in response to the scram signal. The bridge unbalance reversal is then utilized to prevent the actuation of the ball backup system, or, conversely, a failure of the safety rods to produce the predetermined effect produces no unbalance reversal and the ball backup system is actuated. (AEC)
STS-47 crew and backups at MSFC's Payload Crew Training Complex
NASA Technical Reports Server (NTRS)
1992-01-01
STS-47 Endeavour, Orbiter Vehicle (OV) 105, Spacelab Japan (SLJ) crewmembers and backup payload specialists stand outside SLJ module mockup at the Payload Crew Training Complex at Marshall SpaceFlight Center (MSFC) in Huntsville, Alabama. From left to right are Payload Specialist Mamoru Mohri, backup Payload Specialist Takao Doi, backup Payload Specialist Chiaki Naito-Mukai, Mission Specialist (MS) Mae C. Jemison, MS N. Jan Davis, backup Payload Specialist Stan Koszelak, and MS and Payload Commander (PLC) Mark C. Lee. The MSFC-managed mission is a joint venture in space-based research between the United States and Japan. Mohri, Doi, and Mukai represent Japan's National Space Development Agency (NASDA). View provided with alternate number 92P-142.
Tatsumi, Daisaku; Nakada, Ryosei; Ienaga, Akinori; Yomoda, Akane; Inoue, Makoto; Ichida, Takao; Hosono, Masako
2012-01-01
The tolerance of the Backup diaphragm (Backup JAW) setting in Elekta linac was specified as 2 mm according to the AAPM TG-142 report. However, the tolerance and the quality assurance procedure for volumetric modulated arc therapy (VMAT) was not provided. This paper describes positional accuracy and quality assurance procedure of the Backup JAWs required for VMAT. It was found that a gap-width error of the Backup JAW by a sliding window test needed to be less than 1.5 mm for prostate VMAT delivery. It was also confirmed that the gap-widths had been maintained with an error of 0.2 mm during the past one year.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Binh T. Pham; Nancy J. Lybeck; Vivek Agarwal
The Light Water Reactor Sustainability program at Idaho National Laboratory is actively conducting research to develop and demonstrate online monitoring capabilities for active components in existing nuclear power plants. Idaho National Laboratory and the Electric Power Research Institute are working jointly to implement a pilot project to apply these capabilities to emergency diesel generators and generator step-up transformers. The Electric Power Research Institute Fleet-Wide Prognostic and Health Management Software Suite will be used to implement monitoring in conjunction with utility partners: Braidwood Generating Station (owned by Exelon Corporation) for emergency diesel generators, and Shearon Harris Nuclear Generating Station (owned bymore » Duke Energy Progress) for generator step-up transformers. This report presents monitoring techniques, fault signatures, and diagnostic and prognostic models for emergency diesel generators. Emergency diesel generators provide backup power to the nuclear power plant, allowing operation of essential equipment such as pumps in the emergency core coolant system during catastrophic events, including loss of offsite power. Technical experts from Braidwood are assisting Idaho National Laboratory and Electric Power Research Institute in identifying critical faults and defining fault signatures associated with each fault. The resulting diagnostic models will be implemented in the Fleet-Wide Prognostic and Health Management Software Suite and tested using data from Braidwood. Parallel research on generator step-up transformers was summarized in an interim report during the fourth quarter of fiscal year 2012.« less
NASA Astrophysics Data System (ADS)
Yadav, Dharmendra Singh; Babu, Sarath; Manoj, B. S.
2018-03-01
Spectrum conflict during primary and backup routes assignment in elastic optical networks results in increased resource consumption as well as high Bandwidth Blocking Probability. In order to avoid such conflicts, we propose a new scheme, Quasi Path Restoration (QPR), where we divide the available spectrum into two: (1) primary spectrum (for primary routes allocation) and (2) backup spectrum (for rerouting the data on link failures). QPR exhibits three advantages over existing survivable strategies such as Shared Path Protection (SPP), Primary First Fit Backup Last Fit (PFFBLF), Jointly Releasing and re-establishment Defragmentation SPP (JRDSSPP), and Path Restoration (PR): (1) the conflict between primary and backup spectrum during route assignment is completely eliminated, (2) upon a link failure, connection recovery requires less backup resources compared to SPP, PFFBLF, and PR, and (3) availability of the same backup spectrum on each link improves the recovery guarantee. The performance of our scheme is analyzed with different primary backup spectrum partitions on varying connection-request demands and number of frequency slots. Our results show that QPR provides better connection recovery guarantee and Backup Resources Utilization (BRU) compared to bandwidth recovery of PR strategy. In addition, we compare QPR with Shared Path Protection and Primary First-Fit Backup Last Fit strategies in terms of Bandwidth Blocking Probability (BBP) and average frequency slots per connection request. Simulation results show that BBP of SPP, PFFBLF, and JRDSPP varies between 18.59% and 14.42%, while in QPR, BBP ranges from 2.55% to 17.76% for Cost239, NSFNET, and ARPANET topologies. Also, QPR provides bandwidth recovery between 93.61% and 100%, while in PR, the recovery ranges from 86.81% to 98.99%. It is evident from our analysis that QPR provides a reasonable trade-off between bandwidth blocking probability and connection recoverability.
Fuel Cells for Backup Power in Telecommunications Facilities (Fact Sheet)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
2009-04-01
Telecommunications providers rely on backup power to maintain a constant power supply, to prevent power outages, and to ensure the operability of cell towers, equipment, and networks. The backup power supply that best meets these objectives is fuel cell technology.
Optimal fault-tolerant control strategy of a solid oxide fuel cell system
NASA Astrophysics Data System (ADS)
Wu, Xiaojuan; Gao, Danhui
2017-10-01
For solid oxide fuel cell (SOFC) development, load tracking, heat management, air excess ratio constraint, high efficiency, low cost and fault diagnosis are six key issues. However, no literature studies the control techniques combining optimization and fault diagnosis for the SOFC system. An optimal fault-tolerant control strategy is presented in this paper, which involves four parts: a fault diagnosis module, a switching module, two backup optimizers and a controller loop. The fault diagnosis part is presented to identify the SOFC current fault type, and the switching module is used to select the appropriate backup optimizer based on the diagnosis result. NSGA-II and TOPSIS are employed to design the two backup optimizers under normal and air compressor fault states. PID algorithm is proposed to design the control loop, which includes a power tracking controller, an anode inlet temperature controller, a cathode inlet temperature controller and an air excess ratio controller. The simulation results show the proposed optimal fault-tolerant control method can track the power, temperature and air excess ratio at the desired values, simultaneously achieving the maximum efficiency and the minimum unit cost in the case of SOFC normal and even in the air compressor fault.
McColloster, Patrick J; Martin-de-Nicolas, Andres
2014-01-01
This commentary reviews recent changes in Centers for Disease Control (CDC) vaccine storage guidelines that were developed in response to an investigative report by the Office of the Inspector General. The use of temperature data loggers with probes residing in glycol vials is advised along with storing vaccines in pharmaceutical refrigerators. These refrigerators provide good thermal distribution but can warm to 8 °C in less than one hour after the power is discontinued. Consequently, electric grid instability influences appropriate refrigerator selection and the need for power back-up. System Average Interruption Duration Index (SAIDI) values quantify this instability and can be used to formulate region-specific guidelines. A novel aftermarket refrigerator regulator with a battery back-up power supply and microprocessor control system is also described. PMID:24442209
Vaccine refrigeration: thinking outside of the box.
McColloster, Patrick J; Martin-de-Nicolas, Andres
2014-01-01
This commentary reviews recent changes in Centers for Disease Control (CDC) vaccine storage guidelines that were developed in response to an investigative report by the Office of the Inspector General. The use of temperature data loggers with probes residing in glycol vials is advised along with storing vaccines in pharmaceutical refrigerators. These refrigerators provide good thermal distribution but can warm to 8 °C in less than one hour after the power is discontinued. Consequently, electric grid instability influences appropriate refrigerator selection and the need for power back-up. System Average Interruption Duration Index (SAIDI) values quantify this instability and can be used to formulate region-specific guidelines. A novel aftermarket refrigerator with a battery back-up power supply and microprocessor control system is also described.
NASA Technical Reports Server (NTRS)
Walsh, K. R.; Burcham, F. W.
1984-01-01
The backup control (BUC) features, the operation of the BUC system, the BUC control logic, and the BUC flight test results are described. The flight test results include: (1) transfers to the BUC at military and maximum power settings; (2) a military power acceleration showing comparisons bvetween flight and simulation for BUC and primary modes; (3) steady-state idle power showing idle compressor speeds at different flight conditions; and (4) idle-to-military power BUC transients showing where cpmpressor stalls occurred for different ramp rates and idle speeds. All the BUC transfers which occur during the DEEC flight program are initiated by the pilot. Automatic transfers to the BUC do not occur.
Disaster-hardened imaging POD for PACS
NASA Astrophysics Data System (ADS)
Honeyman-Buck, Janice; Frost, Meryll
2005-04-01
After the events of 9/11, many people questioned their ability to keep critical services operational in the face of massive infrastructure failure. Hospitals increased their backup and recovery power, made plans for emergency water and food, and operated on a heightened alert awareness with more frequent disaster drills. In a film-based radiology department, if a portable X-ray unit, a CT unit, an Ultrasound unit, and an film processor could be operated on emergency power, a limited, but effective number of studies could be performed. However, in a digital department, there is a reliance on the network infrastructure to deliver images to viewing locations. The system developed for our institution uses several imaging PODS, a name we chose because it implied to us a safe, contained environment. Each POD is a stand-alone emergency powered network capable of generating images and displaying them in the POD or printing them to a DICOM printer. The technology we used to create a POD consists of a computer with dual network interface cards joining our private, local POD network, to the hospital network. In the case of an infrastructure failure, each POD can and does work independently to produce CTs, CRs, and Ultrasounds. The system has been tested during disaster drills and works correctly, producing images using equipment technologists are comfortable using with very few emergency switch-over tasks. Purpose: To provide imaging capabilities in the event of a natural or man-made disaster with infrastructure failure. Method: After the events of 9/11, many people questioned their ability to keep critical services operational in the face of massive infrastructure failure. Hospitals increased their backup and recovery power, made plans for emergency water and food, and operated on a heightened alert awareness with more frequent disaster drills. In a film-based radiology department, if a portable X-ray unit, a CT unit, an Ultrasound unit, and an film processor could be operated on emergency power, a limited, but effective number of studies could be performed. However, in a digital department, there is a reliance on the network infrastructure to deliver images to viewing locations. The system developed for our institution uses several imaging PODS, a name we chose because it implied to us a safe, contained environment. Each POD is on both the standard and the emergency power systems. All the vendor equipment that produces images is on a private, stand-alone network controlled either by a simple or a managed switch. Included in each POD is a dry-process DICOM printer that is rarely used during normal operations and a display workstation. One node on the private network is a PACS application processor (AP) with two network interface cards, one for the private network, one for the standard PACS network. During ordinary daily operations, all acquired images pass through this AP and are routed to the PACS archives, web servers, and workstations. However, if the power and network to much of the hospital were to fail, the stand-alone POD could still function. Images are routed to the AP, but cannot forward to the main network. However, they can be routed to the printer and display in the POD. They are also stored on the AP to continue normal routing when the infrastructure is restored. Results: The imaging PODS have been tested in actual disaster testing where the infrastructure was intentionally removed and worked as designed. To date, we have not had to use them in a real-life scenario and we hope we never do, but we feel we have a reasonable level of emergency imaging capability if we ever need it. Conclusions: Our testing indicates our PODS are a viable way to continue medical imaging in the face of an emergency with a major part of our network and electrical infrastructure destroyed.
Flight evaluation results for a digital electronic engine control in an F-15 airplane
NASA Technical Reports Server (NTRS)
Burcham, F. W., Jr.; Myers, L. P.; Walsh, K. R.
1983-01-01
A digital electronic engine control (DEEC) system on an F100 engine in an F-15 airplane was evaluated in flight. Thirty flights were flown in a four-phase program from June 1981 to February 1983. Significant improvements in the operability and performance of the F100 engine were developed as a result of the flight evaluation: the augmentor envelope was increased by 15,000 ft, the airstart envelope was improved by 75 knots, and the need to periodically trim the engine was eliminated. The hydromechanical backup control performance was evaluated and was found to be satisfactory. Two system failures were encountered in the test program; both were detected and accommodated successfully. No transfers to the backup control system were required, and no automatic transfers occurred. As a result of the successful DEEC flight evaluation, the DEEC system has entered the full-scale development phase.
75 FR 81417 - Airworthiness Directives; Piper Aircraft, Inc. Model PA-28-161 Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2010-12-28
... authority digital engine control (FADEC) backup battery, replacing the supplement pilot's operating handbook... installation of a FADEC backup battery, replacement of the supplement pilot's operating handbook and FAA... backup battery 7 work-hours x $85 per $780 $1,375 Not hour = $595. applicable. Authority for This...
Klein, Sharon J W
2013-12-17
Decisions about energy backup and cooling options for parabolic trough (PT) concentrated solar power have technical, economic, and environmental implications. Although PT development has increased rapidly in recent years, energy policies do not address backup or cooling option requirements, and very few studies directly compare the diverse implications of these options. This is the first study to compare the annual capacity factor, levelized cost of energy (LCOE), water consumption, land use, and life cycle greenhouse gas (GHG) emissions of PT with different backup options (minimal backup (MB), thermal energy storage (TES), and fossil fuel backup (FF)) and different cooling options (wet (WC) and dry (DC). Multicriteria decision analysis was used with five preference scenarios to identify the highest-scoring energy backup-cooling combination for each preference scenario. MB-WC had the highest score in the Economic and Climate Change-Economy scenarios, while FF-DC and FF-WC had the highest scores in the Equal and Availability scenarios, respectively. TES-DC had the highest score for the Environmental scenario. DC was ranked 1-3 in all preference scenarios. Direct comparisons between GHG emissions and LCOE and between GHG emissions and land use suggest a preference for TES if backup is require for PT plants to compete with baseload generators.
An Overview of the NASA F-18 High Alpha Research Vehicle
NASA Technical Reports Server (NTRS)
Bowers, Albion H.; Pahle, Joseph W.; Wilson, R. Joseph; Flick, Bradley C.; Rood, Richard L.
1996-01-01
This paper gives an overview of the NASA F-18 High Alpha Research Vehicle. The three flight phases of the program are introduced, along with the specific goals and data examples taken during each phase. The aircraft configuration and systems needed to perform the disciplinary and inter-disciplinary research are discussed. The specific disciplines involved with the flight research are introduced, including aerodynamics, controls, propulsion, systems, and structures. Decisions that were made early in the planning of the aircraft project and the results of those decisions are briefly discussed. Each of the three flight phases corresponds to a particular aircraft configuration, and the research dictated the configuration to be flown. The first phase gathered data with the baseline F-18 configuration. The second phase was the thrust-vectoring phase. The third phase used a modified forebody with deployable nose strakes. Aircraft systems supporting these flights included extensive instrumentation systems, integrated research flight controls using flight control hardware and corresponding software, analog interface boxes to control forebody strakes, a thrust-vectoring system using external post-exit vanes around axisymmetric nozzles, a forebody vortex control system with strakes, and backup systems using battery-powered emergency systems and a spin recovery parachute.
Fault-tolerant back-up archive using an ASP model for disaster recovery
NASA Astrophysics Data System (ADS)
Liu, Brent J.; Huang, H. K.; Cao, Fei; Documet, Luis; Sarti, Dennis A.
2002-05-01
A single point of failure in PACS during a disaster scenario is the main archive storage and server. When a major disaster occurs, it is possible to lose an entire hospital's PACS data. Few current PACS archives feature disaster recovery, but the design is limited at best. These drawbacks include the frequency with which the back-up is physically removed to an offsite facility, the operational costs associated to maintain the back-up, the ease-of-use to perform the backup consistently and efficiently, and the ease-of-use to perform the PACS image data recovery. This paper describes a novel approach towards a fault-tolerant solution for disaster recovery of short-term PACS image data using an Application Service Provider model for service. The ASP back-up archive provides instantaneous, automatic backup of acquired PACS image data and instantaneous recovery of stored PACS image data all at a low operational cost. A back-up archive server and RAID storage device is implemented offsite from the main PACS archive location. In the example of this particular hospital, it was determined that at least 2 months worth of PACS image exams were needed for back-up. Clinical data from a hospital PACS is sent to this ASP storage server in parallel to the exams being archived in the main server. A disaster scenario was simulated and the PACS exams were sent from the offsite ASP storage server back to the hospital PACS. Initially, connectivity between the main archive and the ASP storage server is established via a T-1 connection. In the future, other more cost-effective means of connectivity will be researched such as the Internet 2. A disaster scenario was initiated and the disaster recovery process using the ASP back-up archive server was success in repopulating the clinical PACS within a short period of time. The ASP back-up archive was able to recover two months of PACS image data for comparison studies with no complex operational procedures. Furthermore, no image data loss was encountered during the recovery.
10 CFR 830 Major Modification Determination for the ATR Diesel Bus (E-3) and Switchgear Replacement
DOE Office of Scientific and Technical Information (OSTI.GOV)
Noel Duckwtiz
2011-05-01
Near term replacement of aging and obsolescent original ATR equipment has become important to ensure ATR capability in support of NE’s long term national missions. To that end, a mission needs statement has been prepared for a non-major system acquisition which is comprised of three interdependent subprojects. The first project, subject of this determination, will replace the existent diesel-electrical bus (E-3) and associated switchgear. More specifically, INL proposes transitioning ATR to 100% commercial power with appropriate emergency backup to include: • Provide commercial power as the normal source of power to the ATR loads currently supplied by diesel-electric power. •more » Provide backup power to the critical ATR loads in the event of a loss of commercial power. • Replace obsolescent critical ATR power distribution equipment, e.g., switchgear, transformers, motor control centers, distribution panels. Completion of this and two other age-related projects (primary coolant pump and motor replacement and emergency firewater injection system replacement) will resolve major age related operational issues plus make a significant contribution in sustaining the ATR safety and reliability profile. The major modification criteria evaluation of the project pre-conceptual design identified several issues make the project a major modification: 1. Evaluation Criteria #2 (Footprint change). The addition of a new PC-4 structure to the ATR Facility to house safety-related SSCs requires careful attention to maintaining adherence to applicable engineering and nuclear safety design criteria (e.g., structural qualification, fire suppression) to ensure no adverse impacts to the safety-related functions of the housed equipment. 2. Evaluation Criteria #3 (Change of existing process). The change to the strategy for providing continuous reliable power to the safety-related emergency coolant pumps requires careful attention and analysis to ensure it meets a project primary object to maintain or reduce CDF and does not negatively affect the efficacy of the currently approved strategy. 3. Evaluation Criteria #5 (Create the need for new or revised safety SSCs). The change to the strategy for providing continuous reliable power to the safety-related emergency coolant pumps, based on the pre-conceptual design, will require the addition of two quick start diesel generators, their associated power coordination/distribution controls, and a UPS to the list of safety-related SSCs. Similarly to item 1 above, the addition of these active SSCs to the list of safety-related SSCs and replacement of the E-3 bus requires careful attention to maintaining adherence to applicable engineering and nuclear safety design criteria (e.g., seismic qualification, isolation of redundant trains from common fault failures) to ensure no adverse impacts to the safety-related functions.« less
Value of the internet in emergency response.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Herzenberg, C. L.; Newsom, D. E.; Swietlik, C. E.
1999-05-26
Can the Internet be of value in emergency response? The answer is yes, judging by its use in the Kobe earthquake in Japan in 1995, ice storms in the US and Canada in 1998, and other disasters. Current and future areas of application are numerous, including exchanging messages, documents, and data files via e-mail; accessing operational data on-line; visualizing events via photos and maps; providing backup communications in lieu of broadcast media, exchanging information between crisis managers and responders; and providing information to media and the public. However, the Internet has some drawbacks, such as hardware/software requirements, computer literacy requirements,more » traffic jams, dependence on power and communication networks, and risks to information integrity and security. This paper examines some of the advantages, drawbacks, concerns, and potential uses of the Internet for emergency response.« less
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-20
... NATIONAL ARCHIVES AND RECORDS ADMINISTRATION [NARA-2014-011] Proposed Disposal of George H.W. Bush... George H.W. Bush and Clinton Administration Disaster Recovery Backup Tapes; final agency action. SUMMARY... collection of disaster recovery backup tapes from the George H.W. Bush and Clinton administrations under the...
12 CFR 201.4 - Availability and terms of credit.
Code of Federal Regulations, 2014 CFR
2014-01-01
... overnight, as a backup source of funding to a depository institution that is in generally sound financial... to a few weeks as a backup source of funding to a depository institution if, in the judgment of the... very short-term basis, usually overnight, as a backup source of funding to a depository institution...
Materials safety data sheets the basis for control of toxic chemicals. Volume II
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bolton, N. E.; Ketchen, E. E.; Porter, W. E.
For large industrial and research operations, maintaining reasonable control of all toxic materials used in their operations can be a formidable task. A system utilizing cards has been developed that serves a dual purpose, informing the user regarding hazards of a particular material and also facilitating appropriate workplace surveillance during its use. Selected data, including threshold limit values, routes of absorption, symptoms of exposure, chronic effects, and emergency first-aid procedures, are printed on the card. A portion of the card contains the label that the user detaches and affixes to the container. This label classifies the material according to flammability,more » toxicity, reactivity, and special properties on a 0 through 4 hazard rating system. This report describes the development and use of such cards, contains the associated Toxic Material Data Sheets that provide full backup data for the labels, and furnishes a glossary of biomedical terms used in the Data Sheets.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Anderson, David M.; Hoffman, Michael G.; Niemeyer, Jackie M.
This report examines the information and communications technology (ICT) services industry in response to an inquiry by the Department of Energy’s (DOE’s) Office of Energy Policy and Systems Analysis. The report answers several key questions: •How has the reliance on ICT services evolved in recent years for key infrastructure services such as air travel, freight transport, electricity and natural gas distribution, financial services, and critical health care, and for the household sector? •What ICT industry trends explain continued strong linkage to and reliance upon ICT? •What is the ICT industry’s reliance on grid-supplied power, uninterruptible power supplies, emergency generators andmore » back-up energy storage technologies? •What are the observed direct effects of ICT disruptions induced by electrical system failures in recent history and how resilient are the components of the ICT industry?« less
I Am Working for ___: Successfully Using Token Reward Systems
ERIC Educational Resources Information Center
Diamond, Gwendolyn P.; Da Fonte, M. Alexandra; Boesch, Miriam C.
2015-01-01
The use of these systems can enhance students' participation in instructional activities. However, to use token systems effectively, the system must be individualized and tailored to meet the needs of the child. In order to individualize the token system for each student, teachers should (1) identify an array of back-up reinforcers for the…
New York State Public Health System Response to Hurricane Sandy: Lessons From the Field.
Shipp Hilts, Asante; Mack, Stephanie; Eidson, Millicent; Nguyen, Trang; Birkhead, Guthrie S
2016-06-01
The aim of this study was to conduct interviews with public health staff who responded to Hurricane Sandy and to analyze their feedback to assess response strengths and challenges and recommend improvements for future disaster preparedness and response. Qualitative analysis was conducted of information from individual confidential interviews with 35 staff from 3 local health departments in New York State (NYS) impacted by Hurricane Sandy and the NYS Department of Health. Staff were asked about their experiences during Hurricane Sandy and their recommendations for improvements. Open coding was used to analyze interview transcripts for reoccurring themes, which were labeled as strengths, challenges, or recommendations and then categorized into public health preparedness capabilities. The most commonly cited strengths, challenges, and recommendations related to the Hurricane Sandy public health response in NYS were within the emergency operations coordination preparedness capability, which includes the abilities of health department staff to partner among government agencies, coordinate with emergency operation centers, conduct routine conference calls with partners, and manage resources. Health departments should ensure that emergency planning includes protocols to coordinate backup staffing, delineation of services that can be halted during disasters, clear guidelines to coordinate resources across agencies, and training for transitioning into unfamiliar disaster response roles. (Disaster Med Public Health Preparedness. 2016;10:443-453).
DOT National Transportation Integrated Search
2013-05-01
Renewable electric power production could reduce highway maintenance and operating costs and provide backup for critical systems during power outages. Using the public right-of-way and roadway infrastructure as a source for energy production, storage...
Ruckart, Perri Zeitz; Orr, Maureen F; Lanier, Kenneth; Koehler, Allison
2008-11-15
The scientific literature concerning the public health response to the unprecedented hurricanes striking the Gulf Coast in August and September 2005 has focused mainly on assessing health-related needs and surveillance of injuries, infectious diseases, and other illnesses. However, the hurricanes also resulted in unintended hazardous substances releases in the affected states. Data from two states (Louisiana and Texas) participating in the Hazardous Substances Emergency Events Surveillance (HSEES) system were analyzed to describe the characteristics of hazardous substances releases in industrial settings associated with Hurricanes Katrina and Rita. HSEES is an active multi-state Web-based surveillance system maintained by the Agency for Toxic Substances and Disease Registry (ATSDR). In 2005, 166 hurricane-related hazardous substances events in industrial settings in Louisiana and Texas were reported. Most (72.3%) releases were due to emergency shut downs in preparation for the hurricanes and start-ups after the hurricanes. Emphasis is given to the contributing causal factors, hazardous substances released, and event scenarios. Recommendations are made to prevent or minimize acute releases of hazardous substances during future hurricanes, including installing backup power generation, securing equipment and piping to withstand high winds, establishing procedures to shutdown process operations safely, following established and up-to-date start-up procedures and checklists, and carefully performing pre-start-up safety reviews.
Achieving reliability - The evolution of redundancy in American manned spacecraft computers
NASA Technical Reports Server (NTRS)
Tomayko, J. E.
1985-01-01
The Shuttle is the first launch system deployed by NASA with full redundancy in the on-board computer systems. Fault-tolerance, i.e., restoring to a backup with less capabilities, was the method selected for Apollo. The Gemini capsule was the first to carry a computer, which also served as backup for Titan launch vehicle guidance. Failure of the Gemini computer resulted in manual control of the spacecraft. The Apollo system served vehicle flight control and navigation functions. The redundant computer on Skylab provided attitude control only in support of solar telescope pointing. The STS digital, fly-by-wire avionics system requires 100 percent reliability. The Orbiter carries five general purpose computers, four being fully-redundant and the fifth being soley an ascent-descent tool. The computers are synchronized at input and output points at a rate of about six times a second. The system is projected to cause a loss of an Orbiter only four times in a billion flights.
A direct methanol fuel cell system to power a humanoid robot
NASA Astrophysics Data System (ADS)
Joh, Han-Ik; Ha, Tae Jung; Hwang, Sang Youp; Kim, Jong-Ho; Chae, Seung-Hoon; Cho, Jae Hyung; Prabhuram, Joghee; Kim, Soo-Kil; Lim, Tae-Hoon; Cho, Baek-Kyu; Oh, Jun-Ho; Moon, Sang Heup; Ha, Heung Yong
In this study, a direct methanol fuel cell (DMFC) system, which is the first of its kind, has been developed to power a humanoid robot. The DMFC system consists of a stack, a balance of plant (BOP), a power management unit (PMU), and a back-up battery. The stack has 42 unit cells and is able to produce about 400 W at 19.3 V. The robot is 125 cm tall, weighs 56 kg, and consumes 210 W during normal operation. The robot is integrated with the DMFC system that powers the robot in a stable manner for more than 2 h. The power consumption by the robot during various motions is studied, and load sharing between the fuel cell and the back-up battery is also observed. The loss of methanol feed due to crossover and evaporation amounts to 32.0% and the efficiency of the DMFC system in terms of net electric power is 22.0%.
Optimized Heat Pipe Backup Cooling System Tested with a Stirling Convertor
NASA Technical Reports Server (NTRS)
Tarau, Calin; Schwendeman, Carl L.; Schifer, Nicholas A.; Anderson, William G.
2016-01-01
Advanced Stirling Radioisotope Generator (ASRG) is an attractive energy system for select space missions, and with the addition of a VCHP, it becomes even more versatile. The ASRG is powered through thermal energy from decaying radioisotopes acting as General Purpose Heat Sources (GPHS). A Stirling engine converts the thermal energy to electrical energy and cools the GPHS [2]. The Stirling convertor must operate continuously to maintain acceptable temperatures of the GPHS and protect their cladding. The addition of alkali metal VCHP allows the Stirling to cycle on and off during a mission and can be used as a backup cooling system. The benefits of being able to turn the Stirling off are: allowing for a restart of the Stirling and reducing vibrations for sensitive measurements. The VCHP addition should also increase the efficiency of the Stirling by providing a uniform temperature distribution at the heat transfer interface into the heater head.
NASA Technical Reports Server (NTRS)
Marshburn, Thomas; Whitmore, Mihriban; Ortiz, Rosie; Segal, Michele; Smart, Kieran; Hughes, Catherine
2003-01-01
Emergency medical capabilities aboard the ISS include a Crew Medical Officer (CMO) (not necessarily a physician), and back-up, resuscitation equipment, and a medical checklist. It is essential that CMOs have reliable, usable and informative medical protocols that can be carried out independently in flight. The study evaluates the existing ISS Medical Checklist layout against a checklist updated to reflect a human factors approach to structure and organization. Method: The ISS Medical checklist was divided into non-emergency and emergency sections, and re-organized based on alphabetical and a body systems approach. A desk-top evaluation examined the ability of subjects to navigate to specific medical problems identified as representative of likely non-emergency events. A second evaluation aims to focus on the emergency section of the Medical Checklist, based on the preliminary findings of the first. The final evaluation will use Astronaut CMOs as subjects comparing the original checklist against the updated layout in the task of caring for a "downed crewmember" using a Human Patient Simulator [Medical Education Technologies, Inc.]. Results: Initial results have demonstrated a clear improvement of the re-organized sections to determine the solution to the medical problems. There was no distinct advantage for either alternative, although subjects stated having a preference for the body systems approach. In the second evaluation, subjects will be asked to identify emergency medical conditions, with measures including correct diagnosis, time to completion and solution strategy. The third evaluation will compare the original and fully updated checklists in clinical situations. Conclusions: Initial findings indicate that the ISS Medical Checklist will benefit from a reorganization. The present structure of the checklist has evolved over recent years without systematic testing of crewmember ability to diagnose medical problems. The improvements are expected to enable ISS Crewmembers to more speedily and accurately respond to medical situations on the ISS.
``Recent experiences and future expectations in data storage technology''
NASA Astrophysics Data System (ADS)
Pfister, Jack
1990-08-01
For more than 10 years the conventional media for High Energy Physics has been 9 track magnetic tape in various densities. More recently, especially in Europe, the IBM 3480 technology has been adopted while in the United States, especially at Fermilab, 8 mm is being used by the largest experiments as a primary recording media and where possible they are using 8 mm for the production, analysis and distribution of data summary tapes. VHS and Digital Audio tape have recurrently appeared but seem to serve primarily as a back-up storage media. The reasons for what appear to be a radical departure are many. Economics (media and controllers are inexpensive), form factor (two gigabytes per shirt pocket), and convenience (fewer mounts/dismounts per minute) are dominant among the reasons. The traditional data media suppliers seem to have been content to evolve the traditional media at their own pace with only modest enhancements primarily in ``value engineering'' of extant products. Meanwhile, start-up companies providing small system and workstations sought other media both to reduce the price of their offerings and respond to the real need of lower cost back-up for lower cost systems. This happening in a market context where traditional computer systems vendors were leaving the tape market altogether or shifting to ``3480'' technology which has certainly created a climate for reconsideration and change. The newest data storage products, in most cases, are not coming from the technologies developed by the computing industry but by the audio and video industry. Just where these flopticals, opticals, 19 mm tape and the new underlying technologies, such as, ``digital paper'' may fit in the HEP computing requirement picture will be reviewed. What these technologies do for and to HEP will be discussed along with some suggestions for a methodology for tracking and evaluating extant and emerging technologies.
STS-9 payload specialists and backup in training session
NASA Technical Reports Server (NTRS)
1983-01-01
Two Spacelab 1 payload specialists and a backup for that flight prepare for a training session in the JSC mockup and integration laboratory. Fully decked out in the Shuttle constant wear garments (foreground) are Ulf Merbold, left, and Byron K. Licktenberg, prime crewmembers on the STS-9 team. In civilian clothes is payload specialist backup Michael L. Lampton.
Expedition 19 State Commission
2009-03-24
Spaceflight Participant Charles Simonyi, left, Expedition 19 Commander Gennady I. Padalka, Flight Engineer Michael R. Barratt, third from left, backup Expedition 19 flight engineer Maxim Suraev, backup commander Jeffrey Williams and backup spaceflight participant Esther Dyson, far right, are seen in quarantine behind glass during the State Commission meeting on Wednesday, March 25, 2009 in Baikonur, Kazakhstan. Photo Credit: (NASA/Bill Ingalls)
Measuring and analyzing thermal deformations of the primary reflector of the Tianma radio telescope
NASA Astrophysics Data System (ADS)
Dong, Jian; Fu, Li; Liu, Qinghui; Shen, Zhiqiang
2018-06-01
The primary reflector of the Tianma Radio Telescope (TMRT) distorts due to the varying thermal conditions, which dramatically reduces the aperture efficiency of Q-band observations. To evaluate and overcome the thermal effects, a thermal deformations measurement system has been established based on the extended Out-of-Focus holography (e-OOF). The thermal deformations can be measured in approximately 20 min with an illumination-weighted surface root mean square (RMS) accuracy of approximately 50 μm. We have measured the thermal deformations when the backup and front structure were heated by the sun respectively, and used the active surface system to correct the thermal deformations immediately to confirm the measurements. The thermal deformations when the backup structure is heated are larger than those when the front structure is heated. The values of half power beam width (HPBW) are related to the illumination-weighted surface RMS, and can be used to check the thermal deformations. When the backup structure is heated, the aperture efficiencies can remain above 90% of the maximum efficiency at 40 GHz for approximately two hours after one adjustment. While the front structure is heated, the aperture efficiencies can remain above 90% of the maximum efficiency at 40 GHz, and above 95% after one adjustment in approximately three hours.
46 CFR 197.332 - PVHO-Decompression chambers.
Code of Federal Regulations, 2010 CFR
2010-10-01
... dogs, from both sides of a closed hatch; (e) Have interior illumination sufficient to allow visual... (m) Have a sound-powered headset or telephone as a backup to the communications system required by § 197.328(c) (5) and (6), except when that communications system is a sound-powered system. ...
Data systems and computer science space data systems: Onboard memory and storage
NASA Technical Reports Server (NTRS)
Shull, Tom
1991-01-01
The topics are presented in viewgraph form and include the following: technical objectives; technology challenges; state-of-the-art assessment; mass storage comparison; SODR drive and system concepts; program description; vertical Bloch line (VBL) device concept; relationship to external programs; and backup charts for memory and storage.
Low cost passive solar adobe house
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1981-12-21
A brief description, photographs, and cost breakdown of a hybrid direct-gain passive solar adobe house constructed in the City of El Paso, Texas. The 3-panel active solar domestic hot water system acts as a back-up to the direct gain passive system.
STS-47 crew & backups pose for portrait in SLJ module at KSC during training
1992-07-25
S92-44303 --- STS-47 Endeavour, Orbiter Vehicle (OV) 105, crew members and back-up payload specialists, wearing clean suits, pose for a group portrait in the Spacelab Japan (SLJ) module. The team is at the Kennedy Space Center's (KSC's) Orbiter Processing Facility (OPF) to inspect SLJ configuration and OV-105 preparations. Kneeling, from left, are back-up Payload Specialist Chiaki Naito-Mukai; Mission Specialist N. Jan Davis; and backup Payload Specialist Takao Doi. Standing, from the left, are Pilot Curtis L. Brown,Jr; Payload Commander Mark C. Lee; Jerome Apt; Payload Specialist Mamoru Mohri; Commander Robert L. Gibson; Mae C. Jemison; and back-up Payload Specialist Stanely L. Koszelak. Mohri, Mukai, and Doi represent the National Space Development Agency of Japan (NASDA). View provided by KSC with alternate KSC number KSC-92PC-1647. Photo credit: NASA
2017-11-30
jsc2017e136055 - On a snowy night at Red Square in Moscow, Expedition 54-55 backup crewmember Jeanette Epps of NASA lays flowers at the Kremlin Wall where Russian space icons are interred in traditional pre-launch ceremonies Nov. 30. Looking on are backup crewmembers Sergey Prokopyev of the Russian Federal Space Agency (Roscosmos, left) and Alexander Gerst of the European Space Agency. They are backups to Anton Shkaplerov of Roscosmos, Scott Tingle of NASA and Norishige Kanai of the Japan Aerospace Exploration Agency (JAXA), who will launch from the Baikonur Cosmodrome in Kazakhstan on the Soyuz MS-07 spacecraft Dec. 17 for a five-month mission on the International Space Station...Andrey Shelepin/Gagarin Cosmonaut Training Center.
NASA Technical Reports Server (NTRS)
Morinelli, Patrick; Cosgrove, Jennifer; Blizzard, Mike; Robertson, Mike
2007-01-01
This paper provides an overview of the launch and early orbit activities performed by the NASA Goddard Space Flight Center's (GSFC) Flight Dynamics Facility (FDF) in support of five probes comprising the Time History of Events and Macroscale Interactions during Substorms (THEMIS) spacecraft. The FDF was tasked to support THEMIS in a limited capacity providing backup orbit determination support for validation purposes for all five THEMIS probes during launch plus 30 days in coordination with University of California Berkeley Flight Dynamics Center (UCB/FDC)2. The FDF's orbit determination responsibilities were originally planned to be as a backup to the UCB/FDC for validation purposes only. However, various challenges early on in the mission and a Spacecraft Emergency declared thirty hours after launch placed the FDF team in the role of providing the orbit solutions that enabled contact with each of the probes and the eventual termination of the Spacecraft Emergency. This paper details the challenges and various techniques used by the GSFC FDF team to successfully perform orbit determination for all five THEMIS probes during the early mission. In addition, actual THEMIS orbit determination results are presented spanning the launch and early orbit mission phase. Lastly, this paper enumerates lessons learned from the THEMIS mission, as well as demonstrates the broad range of resources and capabilities within the FDF for supporting critical launch and early orbit navigation activities, especially challenging for constellation missions.
NASA Technical Reports Server (NTRS)
Morinelli, Patrick; Cosgrove, jennifer; Blizzard, Mike; Nicholson, Ann; Robertson, Mika
2007-01-01
This paper provides an overview of the launch and early orbit activities performed by the NASA Goddard Space Flight Center's (GSFC) Flight Dynamics Facility (FDF) in support of five probes comprising the Time History of Events and Macroscale Interactions during Substorms (THEMIS) spacecraft. The FDF was tasked to support THEMIS in a limited capacity providing backup orbit determination support for validation purposes for all five THEMIS probes during launch plus 30 days in coordination with University of California Berkeley Flight Dynamics Center (UCB/FDC). The FDF's orbit determination responsibilities were originally planned to be as a backup to the UCB/FDC for validation purposes only. However, various challenges early on in the mission and a Spacecraft Emergency declared thirty hours after launch placed the FDF team in the role of providing the orbit solutions that enabled contact with each of the probes and the eventual termination of the Spacecraft Emergency. This paper details the challenges and various techniques used by the GSFC FDF team to successfully perform orbit determination for all five THEMIS probes during the early mission. In addition, actual THEMIS orbit determination results are presented spanning the launch and early orbit mission phase. Lastly, this paper enumerates lessons learned from the THEMIS mission, as well as demonstrates the broad range of resources and capabilities within the FDF for supporting critical launch and early orbit navigation activities, especially challenging for constellation missions.
Alali, Khaled; Casali, John G
2012-01-01
The purpose of this study was to assess normal hearing listeners' performance in detecting a stationary backup alarm signal and to quantify the linear distance at detection point. Detection distances for 12 participants with normal hearing were measured while they were fitted with 7 hearing protectors and while they were unoccluded (open ear). A standard (narrowband) backup alarm signal and a broadband (pulsed white noise) backup alarm signal from Brigade[1] were used. The method of limits, with distance as the physical measurement variable and threshold detection as the task, was employed to find at which distance the participant could first detect the backup alarms. A within-subject Analysis of Variance (ANOVA) revealed a significant main effect of the listening conditions on the detection distance in feet. Post hoc analyses indicated that the Bilsom L3HV conventional passive earmuff (at 1132.2 ft detection distance) was significantly poorer compared to all other HPDs and the open ear in detection distance achieved, and that there were no statistically-significant differences between the unoccluded ear (1652.3 ft), EB-15-Lo BlastPLGTM (1546.2 ft), EB-15-Hi BlastPLGTM (1543.4 ft), E-A-R/3M Combat ArmsTM earplug-nonlinear, level-dependent state (1507.8 ft), E-A-R/3M HiFiTM earplug (1497.7 ft), and Bilsom ImpactTM dichotic electronic earmuff (1567.2 ft). In addition, the E-A-R/3M Combat ArmsTM earplug-passive steady state resulted in significantly longer detection distances than only the open ear condition, at 1474.1 ft versus 1652.3 ft for the open ear. ANOVA also revealed a significant main effect of the backup alarm type on detection distance. The means were 1600.9 ft for the standard (narrowband) backup alarm signal, and a significantly closer 1379.4 ft was required for the Brigade broadband backup alarm signal. For on-ground workers, it is crucial to detect backup alarm signals as far away as possible rather than at close distances since this will provide them more time to react to approaching vehicles. The results of this study suggest that as the attenuation of the hearing protectors increases, precautions should be considered by safety professionals. This is because, as it was the case with the Bilsom passive earmuff and E-A-R/3M Combat ArmsTM earplug-passive steady state, high attenuation minimizes the detection distance and as a result on-foot workers will have less time to react to any approaching vehicle. The main effects of the type of backup alarm signal demonstrated a statistically-significant advantage of the standard backup alarm over the broadband backup alarm on detection distance in feet. The magnitude of the improvement produced by the standard backup alarm was 221.5 feet, a very large margin. For example, with a vehicle backing at 10 mph, the 221.5 ft decrease in detection distance with the Brigade alarm equates to the vehicle arriving 15 seconds sooner at the worker from the point at which its alarm was first heard.
Researching, Evaluating, and Choosing a Backup Service in the Cloud
ERIC Educational Resources Information Center
Hastings, Robin
2012-01-01
Backups are a modern fact of life. Every organization that has any kind of computing technology (and that is all of them these days) needs to back up its data in case of technological or user errors. Traditionally, large-scale backups have been done via an internal or external tape drive that takes magnetic tapes (minicassettes, essentially) and…
26 CFR 48.4082-4 - Diesel fuel and kerosene; back-up tax.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 26 Internal Revenue 16 2011-04-01 2011-04-01 false Diesel fuel and kerosene; back-up tax. 48.4082..., and Taxable Fuel Taxable Fuel § 48.4082-4 Diesel fuel and kerosene; back-up tax. (a) Imposition of tax... fuel or kerosene on which tax has not been imposed by section 4081; (ii) Any diesel fuel or kerosene...
26 CFR 48.4082-4 - Diesel fuel and kerosene; back-up tax.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 26 Internal Revenue 16 2012-04-01 2012-04-01 false Diesel fuel and kerosene; back-up tax. 48.4082..., and Taxable Fuel Taxable Fuel § 48.4082-4 Diesel fuel and kerosene; back-up tax. (a) Imposition of tax... fuel or kerosene on which tax has not been imposed by section 4081; (ii) Any diesel fuel or kerosene...
26 CFR 48.4082-4 - Diesel fuel and kerosene; back-up tax.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 26 Internal Revenue 16 2013-04-01 2013-04-01 false Diesel fuel and kerosene; back-up tax. 48.4082..., and Taxable Fuel Taxable Fuel § 48.4082-4 Diesel fuel and kerosene; back-up tax. (a) Imposition of tax... fuel or kerosene on which tax has not been imposed by section 4081; (ii) Any diesel fuel or kerosene...
2012-06-20
At the Gagarin Cosmonaut Training Center in Star City, Russia, the Expedition 32/33 backup crew posed for pictures June 20, 2012 as they participated in the second of two days of Soyuz spacecraft qualification exams. Backup Flight Engineer Chris Hadfield of the Canadian Space Agency (left), backup Flight Engineer Tom Marshburn of NASA (center) and backup Soyuz Commander Roman Romanenko are understudies to the prime crew, NASA Flight Sunita Williams, Aki Hoshide of the Japan Aerospace Exploration Agency and Yuri Malenchenko, who will launch July 15 to the International Space Station in their Soyuz TMA-05M spacecraft from the Baikonur Cosmodrome in Kazakhstan. Credit: NASA/Stephanie Stoll
Improving the Quality of Backup Process for Publishing Houses and Printing Houses
NASA Astrophysics Data System (ADS)
Proskuriakov, N. E.; Yakovlev, B. S.; Pries, V. V.
2018-04-01
The analysis of main types for data threats, used by print media, and their influence on the vitality and security of information is made. The influence of the programs settings for preparing archive files, the types of file managers on the backup process is analysed. We proposed a simple and economical version of the practical implementation of the backup process consisting of 4 components: the command line interpreter, the 7z archiver, the Robocopy utility, and network storage. We recommend that the best option would be to create backup copies, consisting of three local copies of data and two network copies.
NASA Astrophysics Data System (ADS)
Chen, Kebing; Xiao, Tiaojun
2015-11-01
This paper studies the backup sourcing strategy of the buyer and the production planning of the supplier in presence of both random yield and random demand. Since the production is susceptible to the randomness of yield beyond the control of the supplier, the buyer may access to a backup sourcing option for the finished items. We analyse the value of backup sourcing for both the decentralised and centralised channels. Backup sourcing strategy of the buyer may lower the supply chain's performance. We show that the order quantity of the buyer does not change the stocking factor of the supplier's input. Meanwhile, compared with the centralised operation, the decentralised operation is more dependent on the backup sourcing to reduce supply shortage of the contracting supplier. From the channel's perspective, an incentive scheme is developed to facilitate the coordination of both the buyer and the contracting supplier, we show that the proposed option contract can allow the supply chain members to share the respective risks involved in the production and selling processes. Finally, we also provide qualitative insights based on numerical examples of the centralised and decentralised solutions.
technical backup material for the OCE NEMP PROGRAM, Development of Criteria for Protection of NIKE-X Power Plant and Facilities Electrical Systems Against Nuclear Electromagnetic Pulse Effects, Protective MEASURES. (Author)
46 CFR 162.161-4 - Construction.
Code of Federal Regulations, 2014 CFR
2014-10-01
...: SPECIFICATIONS AND APPROVAL ENGINEERING EQUIPMENT Fixed Clean Agent Fire Extinguishing Systems § 162.161-4... mechanical or pneumatic means. (d) Automatically actuated systems must be released by pneumatic or fusible... actuation and have a remote backup manual mechanical actuator. (f) Each container charged with nitrogen must...
46 CFR 162.161-4 - Construction.
Code of Federal Regulations, 2012 CFR
2012-10-01
...: SPECIFICATIONS AND APPROVAL ENGINEERING EQUIPMENT Fixed Clean Agent Fire Extinguishing Systems § 162.161-4... mechanical or pneumatic means. (d) Automatically actuated systems must be released by pneumatic or fusible... actuation and have a remote backup manual mechanical actuator. (f) Each container charged with nitrogen must...
46 CFR 162.161-4 - Construction.
Code of Federal Regulations, 2013 CFR
2013-10-01
...: SPECIFICATIONS AND APPROVAL ENGINEERING EQUIPMENT Fixed Clean Agent Fire Extinguishing Systems § 162.161-4... mechanical or pneumatic means. (d) Automatically actuated systems must be released by pneumatic or fusible... actuation and have a remote backup manual mechanical actuator. (f) Each container charged with nitrogen must...
40 CFR 51.361 - Motorist compliance enforcement.
Code of Federal Regulations, 2011 CFR
2011-07-01
... database, generate computerized notices, and provide regular backup to said system while maintaining auxiliary storage devices to insure ongoing operation of the system and prevent data losses; (vi) Track each... mechanism shall be supported with detailed analyses. (3) The SIP shall include the legal authority to...
ERIC Educational Resources Information Center
Lukac, Jenco; And Others
1981-01-01
Includes Lukac's overview of an online acquisition system, Robert Newhard on information and ordinary living, Theodore Bolton on interactive home television, a survey of the CTI computer backup system by Joseph Covino and Sheila Intner, and three articles about catalogs and cataloging by Kenneth Bierman, Herbert Hoffman, and Judith Hudson. (RAA)
STS-90 M.S. Williams and back-up P.S. Mukai, participate in CEIT
NASA Technical Reports Server (NTRS)
1998-01-01
STS-90 Mission Specialist Dafydd 'Dave' Rhys Williams, M.D., with the Canadian Space Agency, and back-up Payload Specialist Chiaki Mukai, M.D., Ph.D., with the National Space Development Agency of Japan, examine items to be used during the Crew Equipment Interface Test (CEIT) in Kennedy Space Center's (KSC's) Operations and Checkout Building, where the Neurolab payload is undergoing processing. The CEIT gives astronauts an opportunity to get a hands-on look at the payloads with which they will be working on-orbit. STS-90 is scheduled to launch aboard the Shuttle Columbia from KSC on April 2. Investigations during the Neurolab mission will focus on the effects of microgravity on the nervous system. Specifically, experiments will study the adaptation of the vestibular system, the central nervous system, and the pathways that control the ability to sense location in the absence of gravity, as well as the effect of microgravity on a developing nervous system.
46 CFR 197.332 - PVHO-Decompression chambers.
Code of Federal Regulations, 2011 CFR
2011-10-01
... pressure; (d) Have a means of operating all installed man-way locking devices, except disabled shipping... (m) Have a sound-powered headset or telephone as a backup to the communications system required by...
Shuttle avionics software development trials: Tribulations and successes, the backup flight system
NASA Technical Reports Server (NTRS)
Chevers, E. S.
1985-01-01
The development and verification of the Backup Flight System software (BFS) is discussed. The approach taken for the BFS was to develop a very simple and straightforward software program and then test it in every conceivable manner. The result was a program that contained approximately 12,000 full words including ground checkout and the built in test program for the computer. To perform verification, a series of tests was defined using the actual flight type hardware and simulated flight conditions. Then simulated flights were flown and detailed performance analysis was conducted. The intent of most BFS tests was to demonstrate that a stable flightpath could be obtained after engagement from an anomalous initial condition. The extention of the BFS to meet the requirements of the orbital flight test phase is also described.
Cassini Spacecraft In-Flight Swap to Backup Attitude Control Thrusters
NASA Technical Reports Server (NTRS)
Bates, David M.
2010-01-01
NASA's Cassini Spacecraft, launched on October 15th, 1997 and arrived at Saturn on June 30th, 2004, is the largest and most ambitious interplanetary spacecraft in history. In order to meet the challenging attitude control and navigation requirements of the orbit profile at Saturn, Cassini is equipped with a monopropellant thruster based Reaction Control System (RCS), a bipropellant Main Engine Assembly (MEA) and a Reaction Wheel Assembly (RWA). In 2008, after 11 years of reliable service, several RCS thrusters began to show signs of end of life degradation, which led the operations team to successfully perform the swap to the backup RCS system, the details and challenges of which are described in this paper. With some modifications, it is hoped that similar techniques and design strategies could be used to benefit other spacecraft.
ERIC Educational Resources Information Center
La Bar, Nicole J.
To many in the field of early care and education, back-up child care may be viewed as a stressful disruption that could interfere with attachment and be detrimental to continuity of care. This paper attempts to prove that high-quality back-up child care offered by employers actually fosters the development of resiliency in young children by…
26 CFR 48.4082-4 - Diesel fuel and kerosene; back-up tax.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 26 Internal Revenue 16 2010-04-01 2010-04-01 true Diesel fuel and kerosene; back-up tax. 48.4082-4..., and Taxable Fuel Taxable Fuel § 48.4082-4 Diesel fuel and kerosene; back-up tax. (a) Imposition of tax... fuel or kerosene on which tax has not been imposed by section 4081; (ii) Any diesel fuel or kerosene...
Independent backup mode transfer and mechanism for digital control computers
NASA Technical Reports Server (NTRS)
Tulpule, Bhalchandra R. (Inventor); Oscarson, Edward M. (Inventor)
1992-01-01
An interrupt is provided to a signal processor having a non-maskable interrupt input, in response to the detection of a request for transfer to backup software. The signal processor provides a transfer signal to a transfer mechanism only after completion of the present machine cycle. Transfer to the backup software is initiated by the transfer mechanism only upon reception of the transfer signal.
Clinical experiences with an ASP model backup archive for PACS images
NASA Astrophysics Data System (ADS)
Liu, Brent J.; Cao, Fei; Documet, Luis; Huang, H. K.; Muldoon, Jean
2003-05-01
Last year we presented a Fault-Tolerant Backup Archive using an Application Service Provider (ASP) model for disaster recovery. The purpose of this paper is to update and provide clinical experiences related towards implementing the ASP model archive solution for short-term backup of clinical PACS image data as well as possible applications other than disaster recovery. The ASP backup archive provides instantaneous, automatic backup of acquired PACS image data and instantaneous recovery of stored PACS image data all at a low operational cost and with little human intervention. This solution can be used for a variety of scheduled and unscheduled downtimes that occur on the main PACS archive. A backup archive server with hierarchical storage was implemented offsite from the main PACS archive location. Clinical data from a hospital PACS is sent to this ASP storage server in parallel to the exams being archived in the main server. Initially, connectivity between the main archive and the ASP storage server is established via a T-1 connection. In the future, other more cost-effective means of connectivity will be researched such as the Internet 2. We have integrated the ASP model backup archive with a clinical PACS at Saint John's Health Center and has been operational for over 6 months. Pitfalls encountered during integration with a live clinical PACS and the impact to clinical workflow will be discussed. In addition, estimations of the cost of establishing such a solution as well as the cost charged to the users will be included. Clinical downtime scenarios, such as a scheduled mandatory downtime and an unscheduled downtime due to a disaster event to the main archive, were simulated and the PACS exams were sent successfully from the offsite ASP storage server back to the hospital PACS in less than 1 day. The ASP backup archive was able to recover PACS image data for comparison studies with no complex operational procedures. Furthermore, no image data loss was encountered during the recovery. During any clinical downtime scenario, the ASP backup archive server can repopulate a clinical PACS quickly with the majority of studies available for comparison during the interim until the main PACS archive is fully recovered.
1990-06-01
System ACAS Airborne Collision Avoidance System ACB Adjacent Center Backup ACC ACCumulator ACC Area Control Center ACCAS Alto Cumulus CAtellanuS ACCC...subsystem) FFC For Further Clearance FFF Form, Fit, and Function FFF Form, Fix, and Function FFLT Familiarize FLighT FFM Far Field Monitor (associated with
Costs and description of a solar-energy system--Austin, Texas
NASA Technical Reports Server (NTRS)
1981-01-01
Heating and cooling system uses Fresnel lens concentrating collectors. Major system components are 36 collectors, 1,500 gallon thermal storage tank, absorption cooler, cooling tower, heating coil, pumps, heat exchanger, and backup heating and air conditioning. Final report includes detailed breakdown of component and installation costs for seven project subsystems.
Study on a hypothetical replacement of nuclear electricity by wind power in Sweden
NASA Astrophysics Data System (ADS)
Wagner, F.; Rachlew, E.
2016-05-01
The Swedish electricity supply system benefits strongly from the natural conditions which allow a high share of hydroelectricity. A complete supply is, however, not possible. Up to now, nuclear power is the other workhorse to serve the country with electricity. Thus, electricity production of Sweden is basically CO2 -free and Sweden has reached an environmental status which others in Europe plan to reach in 2050. Furthermore, there is an efficient exchange within the Nordic countries, Nordpol, which can ease possible capacity problems during dry cold years. In this study we investigate to what extent and with what consequences the base load supply of nuclear power can be replaced by intermittent wind power. Such a scenario leads unavoidably to high wind power installations. It is shown that hydroelectricity cannot completely smooth out the fluctuations of wind power and an additional back-up system using fossil fuel is necessary. From the operational dynamics, this system has to be based on gas. The back-up system cannot be replaced by a storage using surplus electricity from wind power. The surplus is too little. To overcome this, further strong extension of wind power is necessary which leads, however, to a reduction of the use of hydroelectricity if the annual consumption is kept constant. In this case one fossil-free energy form is replaced by another, however, more complex one. A mix of wind power at 22.3GW plus a gas based back-up system with 8.6GW producing together 64.8TWh would replace the present infrastructure with 9GW nuclear power producing 63.8TWh electricity. The specific CO2 -emission increases to the double in this case. Pumped storage for the exclusive supply of Sweden does not seem to be a meaningful investment.-1
77 FR 24982 - Privacy Act of 1974; System of Records
Federal Register 2010, 2011, 2012, 2013, 2014
2012-04-26
... that documentary (physical, ``hard copies,'' paper, etc.) records are maintained in the same method as.... ADDRESSES: The public, Office of Management and Budget (OMB), and Congress are invited to submit [[Page...), storage area networks, or tape backup systems. Documentary (physical, ``hard copies,'' paper, etc...
2013-05-22
Behind the Cosmonaut Hotel crew quarters in Baikonur, Kazakhstan, the Expedition 36/37 backup and prime crewmembers pose for pictures in front of a Proton rocket statue May 22 following traditional ceremonies. From left to right are backup Flight Engineer Koichi Wakata of the Japan Aerospace Exploration Agency, backup Soyuz Commander Mikhail Tyurin, backup Flight Engineer Rick Mastracchio of NASA, prime Flight Engineer Karen Nyberg of NASA, prime Soyuz Commander Fyodor Yurchikhin and prime Flight Engineer Luca Parmitano of the European Space Agency. Nyberg, Yurchikhin and Parmitano are preparing for their launch May 29, Kazakh time, in the Soyuz TMA-09M spacecraft to begin a 5 ½ month mission on the International Space Station. NASA/Victor Zelentsov
Backup Attitude Control Algorithms for the MAP Spacecraft
NASA Technical Reports Server (NTRS)
ODonnell, James R., Jr.; Andrews, Stephen F.; Ericsson-Jackson, Aprille J.; Flatley, Thomas W.; Ward, David K.; Bay, P. Michael
1999-01-01
The Microwave Anisotropy Probe (MAP) is a follow-on to the Differential Microwave Radiometer (DMR) instrument on the Cosmic Background Explorer (COBE) spacecraft. The MAP spacecraft will perform its mission, studying the early origins of the universe, in a Lissajous orbit around the Earth-Sun L(sub 2) Lagrange point. Due to limited mass, power, and financial resources, a traditional reliability concept involving fully redundant components was not feasible. This paper will discuss the redundancy philosophy used on MAP, describe the hardware redundancy selected (and why), and present backup modes and algorithms that were designed in lieu of additional attitude control hardware redundancy to improve the odds of mission success. Three of these modes have been implemented in the spacecraft flight software. The first onboard mode allows the MAP Kalman filter to be used with digital sun sensor (DSS) derived rates, in case of the failure of one of MAP's two two-axis inertial reference units. Similarly, the second onboard mode allows a star tracker only mode, using attitude and derived rate from one or both of MAP's star trackers for onboard attitude determination and control. The last backup mode onboard allows a sun-line angle offset to be commanded that will allow solar radiation pressure to be used for momentum management and orbit stationkeeping. In addition to the backup modes implemented on the spacecraft, two backup algorithms have been developed in the event of less likely contingencies. One of these is an algorithm for implementing an alternative scan pattern to MAP's nominal dual-spin science mode using only one or two reaction wheels and thrusters. Finally, an algorithm has been developed that uses thruster one shots while in science mode for momentum management. This algorithm has been developed in case system momentum builds up faster than anticipated, to allow adequate momentum management while minimizing interruptions to science. In this paper, each mode and algorithm will be discussed, and simulation results presented.
Energy dashboard for real-time evaluation of a heat pump assisted solar thermal system
NASA Astrophysics Data System (ADS)
Lotz, David Allen
The emergence of net-zero energy buildings, buildings that generate at least as much energy as they consume, has lead to greater use of renewable energy sources such as solar thermal energy. One example is a heat pump assisted solar thermal system, which uses solar thermal collectors with an electrical heat pump backup to supply space heating and domestic hot water. The complexity of such a system can be somewhat problematic for monitoring and maintaining a high level of performance. Therefore, an energy dashboard was developed to provide comprehensive and user friendly performance metrics for a solar heat pump system. Once developed, the energy dashboard was tested over a two-week period in order to determine the functionality of the dashboard program as well as the performance of the heating system itself. The results showed the importance of a user friendly display and how each metric could be used to better maintain and evaluate an energy system. In particular, Energy Factor (EF), which is the ratio of output energy (collected energy) to input energy (consumed energy), was a key metric for summarizing the performance of the heating system. Furthermore, the average EF of the solar heat pump system was 2.29, indicating an efficiency significantly higher than traditional electrical heating systems.
U.S. spacewalk on ISS on This Week @NASA - October 10, 2014
2014-10-10
Aboard the International Space Station, Expedition 41 Flight Engineers Reid Wiseman of NASA and Alexander Gerst of the European Space Agency donned U.S. spacesuits for an October 7 spacewalk to relocate a failed cooling pump and to install a backup power cable device for the station’s rail car system. The failed pump was replaced with a spare and is being temporarily stowed near the Quest airlock and the back-up power cables are for the unlikely event that the Mobile Transporter rail car on the station’s truss loses power. Also, A comet’s Mars flyby, Brightest pulsar! Total Lunar Eclipse and LADEE wins Popular Mechanics award!
NASA Technical Reports Server (NTRS)
Flowers, George T.
1995-01-01
This semiannual status report lists specific accomplishments made on the research of the influence of backup bearings and support structure dynamics on the behavior of rotors with active supports. Papers have been presented representing work done on the T-501 engine model; an experimental/simulation study of auxiliary bearing rotordynamics; and a description of a rotordynamical model for a magnetic bearing supported rotor system, including auxiliary bearing effects. A finite element model for a foil bearing has been developed. Additional studies of rotor/bearing/housing dynamics are currently being performed as are studies of the effects of sideloading on auxiliary bearing rotordynamics using the magnetic bearing supported rotor model.
CPV hybrid system in ISFOC building, first results
NASA Astrophysics Data System (ADS)
Trujillo, Pablo; Alamillo, César; Gil, Eduardo; de la Rubia, Óscar; Martínez, María; Rubio, Francisca; Cadavid, Andros; Navarro, José; Hillenbrand, Sascha; Ballesteros-Sánchez, Isabel; Castillo-Cagigal, Manuel; Masa-Bote, Daniel; Matallanas, Eduardo; Caamaño-Martín, Estefanía; Gutiérrez, Álvaro
2012-10-01
PV Off-Grid systems have demonstrated to be a good solution for the electrification of remote areas [1]. A hybrid system is one kind of these systems. The principal characteristic is that it uses PV as the main generator and has a backup power supply, like a diesel generator, for instance, that is used when the CPV generation is not enough to meet demand. To study the use of CPV in these systems, ISFOC has installed a demonstration hybrid system at its headquarters. This hybrid system uses CPV technology as main generator and the utility grid as the backup generator. A group of batteries have been mounted as well to store the remaining energy from the CPV generator when nedeed. The energy flows are managed by a SMA system based on Sunny Island inverters and a Multicluster-Box (figure 1). The Load is the air-conditioning system of the building, as it has a consumption profile higher than the CPV generator and can be controlled by software [2]. The first results of this system, as well as the first chances of improvement, as the need of a bigger CPV generator and a better management of the energy stored in the batteries, are presented in this paper.
NASA Technical Reports Server (NTRS)
Dunn, William R.; Corliss, Lloyd D.
1991-01-01
Paper examines issue of software safety. Presents four case histories of software-safety analysis. Concludes that, to be safe, software, for all practical purposes, must be free of errors. Backup systems still needed to prevent catastrophic software failures.
Erickson, Michelle L; Champion, Melanie H; Klein, Roger; Ross, Rebecca L; Neal, Zena M; Snyder, Edward L
2008-10-01
Threats to national and local blood supplies in America mandate development of an effective blood management system for emergency preparedness and efficient blood inventory management. Seasonal or acute blood shortages could be compounded by the unavoidable distribution inefficiencies of the blood pipeline during an emergency. The Yale-New Haven Hospital (YNHH) Blood Bank has developed a comprehensive emergency blood management plan, which includes maintenance of a tactical, limited frozen blood supply. A computer spreadsheet-based disaster prediction model has been designed to guide the use of the frozen reserve by testing various emergency scenarios. The frozen blood reserve can likely support normal hospital red blood cell (RBC) demands during typical (3-4 days) seasonal shortages, provide a reduced supply for up to 10 days, or meet an unexpected transient increased RBC demand without requiring intensive support from the regional blood center. However, the frozen blood supply is not designed to meet the massive transfusion demand associated with extreme or sustained disasters. Rather, it serves as a short-term bridge-over supply until blood center support can be reestablished. We review the reasons for initiating a blood management plan and describe how YNHH has implemented and sustains a frozen blood reserve as part of a comprehensive disaster management plan. Despite the operational complexity, the benefits of self-sufficiency, the ability to support routine hospital requirements, and the security of having a backup supply justify the expense and difficulty of maintaining a frozen blood reserve.
Implementation of an ASP model offsite backup archive for clinical images utilizing Internet 2
NASA Astrophysics Data System (ADS)
Liu, Brent J.; Chao, Sander S.; Documet, Jorge; Lee, Jasper; Lee, Michael; Topic, Ian; Williams, Lanita
2005-04-01
With the development of PACS technology and an increasing demand by medical facilities to become filmless, there is a need for a fast and efficient method of providing data backup for disaster recovery and downtime scenarios. At the Image Processing Informatics Lab (IPI), an ASP Backup Archive was developed using a fault-tolerant server with a T1 connection to serve the PACS at the St. John's Health Center (SJHC) Santa Monica, California. The ASP archive server has been in clinical operation for more than 18 months, and its performance was presented at this SPIE Conference last year. This paper extends the ASP Backup Archive to serve the PACS at the USC Healthcare Consultation Center II (HCC2) utilizing an Internet2 connection. HCC2 is a new outpatient facility that recently opened in April 2004. The Internet2 connectivity between USC's HCC2 and IPI has been established for over one year. There are two novelties of the current ASP model: 1) Use of Internet2 for daily clinical operation, and 2) Modifying the existing backup archive to handle two sites in the ASP model. This paper presents the evaluation of the ASP Backup Archive based on the following two criteria: 1) Reliability and performance of the Internet2 connection between HCC2 and IPI using DICOM image transfer in a clinical environment, and 2) Ability of the ASP Fault-Tolerant backup archive to support two separate clinical PACS sites simultaneously. The performances of using T1 and Internet2 at the two different sites are also compared.
Peels, Hans O; de Swart, Hans; Ploeg, Tjeerd V D; Hautvast, Raymond W; Cornel, Jan H; Arnold, Alf E; Wharton, Thomas P; Umans, Victor A
2007-11-01
We investigated whether primary percutaneous coronary intervention (PCI) for patients admitted with an acute ST-segment elevation myocardial infarction could be performed more rapidly and with comparable outcomes in a community hospital versus a tertiary center with cardiac surgery. We started the first PCI with an off-site surgery program in The Netherlands in 2002 and report the results of 439 consecutive patients. In the safety phase, 199 patients presenting with ST-segment elevation myocardial infarction were randomly assigned to treatment at our off-site center versus a more distant cardiac surgery center. In the confirmation phase, 240 consecutive patients were treated in the off-site hospital. Safety and efficacy end points were the rate of an angiographically successful PCI procedure (diameter stenosis <50% and Thrombolysis In Myocardial Infarction grade 3 flow) in the absence of major adverse cardiac and cerebrovascular events at 30 days. The randomization phase showed a 37-minute decrease in door-to-balloon time (p <0.001) with comparable procedural and clinical successes (91% Thrombolysis In Myocardial Infarction grade 3 flow in the 2 groups). In the confirmation phase, the 30-day rate without major adverse cardiac and cerebrovascular events was 95%. None of the 439 patients in the study required emergency surgery for failed primary PCI. In conclusion, time to treatment with primary PCI can be significantly shortened when treating patients in a community hospital setting with off-site cardiac surgery backup compared with transport for PCI to a referral center with on-site surgery. PCI at hospitals with off-site cardiac surgery backup can be considered a needed strategy to improve access to primary PCI for a larger segment of the population and can be delivered with a very favorable safety profile.
Files synchronization from a large number of insertions and deletions
NASA Astrophysics Data System (ADS)
Ellappan, Vijayan; Kumari, Savera
2017-11-01
Synchronization between different versions of files is becoming a major issue that most of the applications are facing. To make the applications more efficient a economical algorithm is developed from the previously used algorithm of “File Loading Algorithm”. I am extending this algorithm in three ways: First, dealing with non-binary files, Second backup is generated for uploaded files and lastly each files are synchronized with insertions and deletions. User can reconstruct file from the former file with minimizing the error and also provides interactive communication by eliminating the frequency without any disturbance. The drawback of previous system is overcome by using synchronization, in which multiple copies of each file/record is created and stored in backup database and is efficiently restored in case of any unwanted deletion or loss of data. That is, to introduce a protocol that user B may use to reconstruct file X from file Y with suitably low probability of error. Synchronization algorithms find numerous areas of use, including data storage, file sharing, source code control systems, and cloud applications. For example, cloud storage services such as Drop box synchronize between local copies and cloud backups each time users make changes to local versions. Similarly, synchronization tools are necessary in mobile devices. Specialized synchronization algorithms are used for video and sound editing. Synchronization tools are also capable of performing data duplication.
NASA Astrophysics Data System (ADS)
King, Nelson E.; Liu, Brent; Zhou, Zheng; Documet, Jorge; Huang, H. K.
2005-04-01
Grid Computing represents the latest and most exciting technology to evolve from the familiar realm of parallel, peer-to-peer and client-server models that can address the problem of fault-tolerant storage for backup and recovery of clinical images. We have researched and developed a novel Data Grid testbed involving several federated PAC systems based on grid architecture. By integrating a grid computing architecture to the DICOM environment, a failed PACS archive can recover its image data from others in the federation in a timely and seamless fashion. The design reflects the five-layer architecture of grid computing: Fabric, Resource, Connectivity, Collective, and Application Layers. The testbed Data Grid architecture representing three federated PAC systems, the Fault-Tolerant PACS archive server at the Image Processing and Informatics Laboratory, Marina del Rey, the clinical PACS at Saint John's Health Center, Santa Monica, and the clinical PACS at the Healthcare Consultation Center II, USC Health Science Campus, will be presented. The successful demonstration of the Data Grid in the testbed will provide an understanding of the Data Grid concept in clinical image data backup as well as establishment of benchmarks for performance from future grid technology improvements and serve as a road map for expanded research into large enterprise and federation level data grids to guarantee 99.999 % up time.
Things That Go "Bump": in the Virtual Night.
ERIC Educational Resources Information Center
Fore, Julie A.
1997-01-01
Introduces concepts of server security and includes articles and sidebars of firsthand accounts of consequences of not devoting enough time to security measures. Outlines the following factors to consider when evaluating a server's risk potential: confidentiality/reproducibility of the data; complexity of the system; backup system and hardware…
NASA Technical Reports Server (NTRS)
Parker, J. F., Jr.; Duffy, J. W.
1982-01-01
Key problems in single pilot instrument flight operations are in the management of flight data and the processing of cockpit information during conditions of heavy workload. A flight data console was developed to allow simulation of a digital data link to replace the current voice communications stem used in air traffic control. This is a human factors evaluation of a data link communications system to determine how such a system might reduce cockpit workload, improve flight proficiency, and be accepted by general aviation pilots. The need for a voice channel as backup to a digital link is examined. The evaluations cover both airport terminal area operations and full mission instrument flight. Results show that general aviation pilots operate well with a digital data link communications system. The findings indicate that a data link system for pilot/ATC communications, with a backup voice channel, is well accepted by general aviation pilots and is considered to be safer, more efficient, and result in less workload than the current voice system.
Prezant, David J; Clair, John; Belyaev, Stanislav; Alleyne, Dawn; Banauch, Gisela I; Davitt, Michelle; Vandervoorts, Kathy; Kelly, Kerry J; Currie, Brian; Kalkut, Gary
2005-01-01
On August 14, 2003, the United States and Canada suffered the largest power failure in history. We report the effects of this blackout on New York City's healthcare system by examining the following: 1) citywide 911 emergency medical service (EMS) calls and ambulance responses; and 2) emergency department (ED) visits and hospital admissions to one of New York City's largest hospitals. Citywide EMS calls and ambulance responses were categorized by 911 call type. Montefiore Medical Center (MMC) ED visits and hospital admissions were categorized by diagnosis and physician-reviewed for relationship to the blackout. Comparisons were made to the week pre- and postblackout. Citywide EMS calls numbered 5,299 on August 14, 2003, and 5,021 on August 15, 2003, a 58% increase (p < .001). During the blackout, there were increases in "respiratory" (189%; p < .001), "cardiac" (68%; p = .016), and "other" (40%; p < .001) EMS call categories, but when expressed as a percent of daily totals, "cardiac" was no longer significant. The MMC-ED reflected this surge with only "respiratory" visits significantly increased (expressed as percent of daily total visits; p < .001). Respiratory device failure (mechanical ventilators, positive pressure breathing assist devices, nebulizers, and oxygen compressors) was responsible for the greatest burden (65 MMC-ED visits, with 37 admissions) as compared with 0 pre- and postblackout. The blackout dramatically increased EMS and hospital activity, with unexpected increases resulting from respiratory device failures in community-based patients. Our findings suggest that current capacity to respond to public health emergencies could be easily overwhelmed by widespread/prolonged power failure(s). Disaster preparedness planning would be greatly enhanced if fully operational, backup power systems were mandated, not only for acute care facilities, but also for community-based patients dependent on electrically powered lifesaving devices.
APOLLO-SOYUZ TEST PROJECT (ASTP) - CREWMEN - JSC
1975-07-09
S75-28361 (9 July 1975) --- These ten American astronauts compose the U.S. prime crew, the backup crew and the crew support team for the joint U.S.-USSR Apollo-Soyuz Test Project docking mission in Earth orbit. They are, left to right, Robert L. Crippen, support team; Robert F. Overmyer, support team; Richard H. Truly, support team; Karol J. Bobko, support team; Donald K. Slayton, prime crew docking module pilot; Thomas P. Stafford, prime crew commander; Vance D. Brand, prime crew command module pilot; Jack R. Lousma, backup crew docking module pilot; Ronald E. Evans, backup crew command module pilot; and Alan L. Bean, backup crew commander. They are photographed by the Apollo Mission Simulator console in Building 5 at NASA's Johnson Space Center.
2012-05-09
In the town of Baikonur, Kazakhstan, the Expedition 31/32 backup crew participated in Victory Day celebration activities May 9, 2012 as they took a break from training for the launch of the Soyuz TMA-04M May 15 to the International Space Station. Victory Day commemorates the triumph of Russia over Nazi Germany in World War II, one of Russia’s most solemn occasions. From left to right holding flowers are backup NASA Flight Engineer Kevin Ford, backup Soyuz Commander Oleg Novitskiy and backup Flight Engineer Evgeny Tarelkin. The prime crew, Gennady Padalka, Sergei Revin and NASA’s Joe Acaba, are training for their launch in the Soyuz vehicle on May 15 for a four-month mission on the orbital complex. NASA/Victor Zelentsov
2012-05-09
In the town of Baikonur, Kazakhstan, the Expedition 31/32 backup crew participated in Victory Day celebration activities May 9, 2012 as they took a break from training for the launch of the Soyuz TMA-04M May 15 to the International Space Station. Victory Day commemorates the triumph of Russia over Nazi Germany in World War II, one of Russia’s most solemn occasions. From left to right holding flowers are backup NASA Flight Engineer Kevin Ford, backup Soyuz Commander Oleg Novitskiy and backup Flight Engineer Evgeny Tarelkin. The prime crew, Gennady Padalka, Sergei Revin and NASA’s Joe Acaba, are training for their launch in the Soyuz vehicle on May 15 for a four-month mission on the orbital complex. NASA/Victor Zelentsov
48 CFR 14.304 - Submission, modification, and withdrawal of bids.
Code of Federal Regulations, 2010 CFR
2010-10-01
... transmitted bid, the data received must not be viewed and, where practicable, must be purged from primary and backup data storage systems. (f) The contracting officer must promptly notify any bidder if its bid...
48 CFR 14.304 - Submission, modification, and withdrawal of bids.
Code of Federal Regulations, 2014 CFR
2014-10-01
... transmitted bid, the data received must not be viewed and, where practicable, must be purged from primary and backup data storage systems. (f) The contracting officer must promptly notify any bidder if its bid...
48 CFR 14.303 - Modification or withdrawal of bids.
Code of Federal Regulations, 2013 CFR
2013-10-01
... for the bid. (c) Upon withdrawal of an electronically transmitted bid, the data received shall not be viewed and shall be purged from primary and backup data storage systems. [48 FR 42171, Sept. 19, 1983, as...
48 CFR 14.303 - Modification or withdrawal of bids.
Code of Federal Regulations, 2012 CFR
2012-10-01
... for the bid. (c) Upon withdrawal of an electronically transmitted bid, the data received shall not be viewed and shall be purged from primary and backup data storage systems. [48 FR 42171, Sept. 19, 1983, as...
48 CFR 14.304 - Submission, modification, and withdrawal of bids.
Code of Federal Regulations, 2011 CFR
2011-10-01
... transmitted bid, the data received must not be viewed and, where practicable, must be purged from primary and backup data storage systems. (f) The contracting officer must promptly notify any bidder if its bid...
48 CFR 14.304 - Submission, modification, and withdrawal of bids.
Code of Federal Regulations, 2013 CFR
2013-10-01
... transmitted bid, the data received must not be viewed and, where practicable, must be purged from primary and backup data storage systems. (f) The contracting officer must promptly notify any bidder if its bid...
48 CFR 14.304 - Submission, modification, and withdrawal of bids.
Code of Federal Regulations, 2012 CFR
2012-10-01
... transmitted bid, the data received must not be viewed and, where practicable, must be purged from primary and backup data storage systems. (f) The contracting officer must promptly notify any bidder if its bid...
48 CFR 14.303 - Modification or withdrawal of bids.
Code of Federal Regulations, 2010 CFR
2010-10-01
... for the bid. (c) Upon withdrawal of an electronically transmitted bid, the data received shall not be viewed and shall be purged from primary and backup data storage systems. [48 FR 42171, Sept. 19, 1983, as...
48 CFR 14.303 - Modification or withdrawal of bids.
Code of Federal Regulations, 2014 CFR
2014-10-01
... for the bid. (c) Upon withdrawal of an electronically transmitted bid, the data received shall not be viewed and shall be purged from primary and backup data storage systems. [48 FR 42171, Sept. 19, 1983, as...
48 CFR 14.303 - Modification or withdrawal of bids.
Code of Federal Regulations, 2011 CFR
2011-10-01
... for the bid. (c) Upon withdrawal of an electronically transmitted bid, the data received shall not be viewed and shall be purged from primary and backup data storage systems. [48 FR 42171, Sept. 19, 1983, as...
Traffic flow characteristic and capacity in intelligent work zones.
DOT National Transportation Integrated Search
2009-10-15
Intellgent transportation system (ITS) technologies are utilized to manage traffic flow and safety in : highway work zones. Traffic management plans for work zones require queuing analyses to determine : the anticipated traffic backups, but the predi...
Design of fuel cell powered data centers for sufficient reliability and availability
NASA Astrophysics Data System (ADS)
Ritchie, Alexa J.; Brouwer, Jacob
2018-04-01
It is challenging to design a sufficiently reliable fuel cell electrical system for use in data centers, which require 99.9999% uptime. Such a system could lower emissions and increase data center efficiency, but the reliability and availability of such a system must be analyzed and understood. Currently, extensive backup equipment is used to ensure electricity availability. The proposed design alternative uses multiple fuel cell systems each supporting a small number of servers to eliminate backup power equipment provided the fuel cell design has sufficient reliability and availability. Potential system designs are explored for the entire data center and for individual fuel cells. Reliability block diagram analysis of the fuel cell systems was accomplished to understand the reliability of the systems without repair or redundant technologies. From this analysis, it was apparent that redundant components would be necessary. A program was written in MATLAB to show that the desired system reliability could be achieved by a combination of parallel components, regardless of the number of additional components needed. Having shown that the desired reliability was achievable through some combination of components, a dynamic programming analysis was undertaken to assess the ideal allocation of parallel components.
42 CFR 488.68 - State Agency responsibilities for OASIS collection and data base requirements.
Code of Federal Regulations, 2010 CFR
2010-10-01
... operating the OASIS system: (a) Establish and maintain an OASIS database. The State agency or other entity designated by CMS must— (1) Use a standard system developed or approved by CMS to collect, store, and analyze..., system back-up, and monitoring the status of the database; and (3) Obtain CMS approval before modifying...
77 FR 37006 - Privacy Act of 1974; System of Records
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-20
... 210, Peterson Air Force Base, CO 80914-4500. Back-up servers: U.S. Strategic Command (USSTRATCOM... JSME Project Manager, U.S. Strategic Command J663, 901 SAC Boulevard, Suite 3J11, Offutt Air Force Base...; System of Records AGENCY: U.S. Strategic Command (USSTRATCOM), DoD. ACTION: Notice to add a system of...
Weber, Juliane; Zachow, Christopher; Witthaut, Dirk
2018-03-01
Wind power generation exhibits a strong temporal variability, which is crucial for system integration in highly renewable power systems. Different methods exist to simulate wind power generation but they often cannot represent the crucial temporal fluctuations properly. We apply the concept of additive binary Markov chains to model a wind generation time series consisting of two states: periods of high and low wind generation. The only input parameter for this model is the empirical autocorrelation function. The two-state model is readily extended to stochastically reproduce the actual generation per period. To evaluate the additive binary Markov chain method, we introduce a coarse model of the electric power system to derive backup and storage needs. We find that the temporal correlations of wind power generation, the backup need as a function of the storage capacity, and the resting time distribution of high and low wind events for different shares of wind generation can be reconstructed.
NASA Astrophysics Data System (ADS)
Weber, Juliane; Zachow, Christopher; Witthaut, Dirk
2018-03-01
Wind power generation exhibits a strong temporal variability, which is crucial for system integration in highly renewable power systems. Different methods exist to simulate wind power generation but they often cannot represent the crucial temporal fluctuations properly. We apply the concept of additive binary Markov chains to model a wind generation time series consisting of two states: periods of high and low wind generation. The only input parameter for this model is the empirical autocorrelation function. The two-state model is readily extended to stochastically reproduce the actual generation per period. To evaluate the additive binary Markov chain method, we introduce a coarse model of the electric power system to derive backup and storage needs. We find that the temporal correlations of wind power generation, the backup need as a function of the storage capacity, and the resting time distribution of high and low wind events for different shares of wind generation can be reconstructed.
More Than 1,000 Fuel Cell Units Deployed Through DOE ARRA Funding (Fact Sheet)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
This NREL Hydrogen and Fuel Cell Technical Highlight describes how early market end users are operating 1,111 fuel cell units at 301 sites in 20 states with funding from the U.S. Department of Energy Fuel Cell Technologies Program and analysis by NREL. The American Recovery and Reinvestment Act (ARRA) funded the deployment of approximately 1,000 fuel cell systems in key early markets to accelerate the commercialization and deployment of fuel cells and fuel cell manufacturing, installation, maintenance, and support services. In support of the ARRA fuel cell deployment objectives, NREL analyzes and validates the technology in real-world applications, reports onmore » the technology status, and facilitates the development of fuel cell technologies, manufacturing, and operations in strategic markets-including material handling equipment, backup power, and stationary power-where fuel cells can compete with conventional technologies. NREL is validating hydrogen and fuel cell systems in real-world settings through data collection, analysis, and reporting. The fuel cell and infrastructure analysis provides an independent, third-party assessment that focuses on fuel cell system and hydrogen infrastructure performance, operation, maintenance, use, and safety. An objective of the ARRA fuel cell project-to deploy approximately 1,000 fuel cell systems in key early markets - has been met in two years. By the end of 2011, 504 material handling equipment (MHE) fuel cell units were operating at 8 facilities and 607 backup power fuel cell units were operating at 293 sites. MHE and backup power are two markets where fuel cells are capable of meeting the operating demands, and deployments can be leveraged to accelerate fuel cell commercialization.« less
Influence of unbalance levels on nonlinear dynamics of a rotor-backup rolling bearing system
NASA Astrophysics Data System (ADS)
Fonseca, Cesar A.; Santos, Ilmar F.; Weber, Hans I.
2017-04-01
Rotor drops in magnetic bearing and unbalance in rotors have been objective of study for many years. The combination of these two well-known phenomena led to an interesting chaotic response, when the rotor touches the inner race of the back-up bearing. The present work explores the nonlinear rotor backup bearing dynamics both theoretically and experimentally using a fully instrumented test rig, where the position of shaft, its angular velocity and the contact forces between the shaft and the backup bearing are sampled at 25 kHz. The test rig is built by a removable passive magnetic bearing, which allows for simulation of magnetic bearing failure (loss of carrying capacity and rotor fall). The rotor is studied numerically as well as experimentally. A theoretical approach is given beforehand and supplies the basis of the study. Finally the presented results are commented on the point of view of nonlinear dynamics applied to the practical use. The theoretical and numerical analyses are shown through orbit plots, phase plans, Poincaré maps, force response in time and double sided spectrum. The latter is important to characterize the condition at different levels of unbalance between forward and backward whirl. Our preliminary results indicate that for smaller amount of unbalance the rotor swings at the bottom of the bearing, the more the unbalance increases, other dynamical behavior occur and some can be extremely harmful, since the rotor can be lifted from the contact state and return, starting to impact innumerable times without reaching a steady state.
How to maintain blood supply during computer network breakdown: a manual backup system.
Zeiler, T; Slonka, J; Bürgi, H R; Kretschmer, V
2000-12-01
Electronic data management systems using computer network systems and client/server architecture are increasingly used in laboratories and transfusion services. Severe problems arise if there is no network access to the database server and critical functions are not available. We describe a manual backup system (MBS) developed to maintain the delivery of blood products to patients in a hospital transfusion service in case of a computer network breakdown. All data are kept on a central SQL database connected to peripheral workstations in a local area network (LAN). Request entry from wards is performed via machine-readable request forms containing self-adhesive specimen labels with barcodes for test tubes. Data entry occurs on-line by bidirectional automated systems or off-line manually. One of the workstations in the laboratory contains a second SQL database which is frequently and incrementally updated. This workstation is run as a stand-alone, read-only database if the central SQL database is not available. In case of a network breakdown, the time-graded MBS is launched. Patient data, requesting ward and ordered tests/requests, are photocopied through a template from the request forms on special MBS worksheets serving as laboratory journal for manual processing and result report (a copy is left in the laboratory). As soon as the network is running again the data from the off-line period are entered into the primary SQL server. The MBS was successfully used at several occasions. The documentation of a 90-min breakdown period is presented in detail. Additional work resulted from the copy work and the belated manual data entry after restoration of the system. There was no delay in issue of blood products or result reporting. The backup system described has been proven to be simple, quick and safe to maintain urgent blood supply and distribution of laboratory results in case of unexpected network breakdown.
Raytheon and NREL Validated Advanced Microgrid System for U.S. Marines |
Schroeder Microgrids can work independently of the traditional grid, making them effective sources of backup work. It truly felt like history in the making." - Mick Wasco, PE, CEM Installation Energy Manager
Emergency contraception. General practitioner knowledge, attitudes and practices in New South Wales.
Weisberg, E; Fraser, I S; Carrick, S E; Wilde, F M
1995-02-06
To assess the knowledge, attitudes and practices of general practitioners in New South Wales regarding the provision of emergency contraception. Randomised group comparison of 100 rural and 100 urban general practitioners (GPs) by questionnaire. Eighty-four rural and 76 urban GPs responded. More rural GPs were knowledgeable about emergency contraception than urban GPs (95% v. 78%), and more women knew about it than men. More urban GPs frequently prescribed emergency contraception than rural GPs (26% v. 6%) and female GPs prescribed it more readily than male GPs (22% v. 12%). There was great variation in the regimens prescribed, especially among rural GPs. Twenty-five per cent of urban GPs and 31% of rural GPs did not offer women information about emergency contraception, while 16% of both groups included such information in any discussion about contraceptive options, and 18% gave information only if requested by the woman. More than 60% of the GPs would provide information about emergency contraception as a back-up to use of barrier methods. The sex, attitude and knowledge of the GPs influence the likelihood of women being made aware of or being given emergency contraception in NSW. There is a need to further educate both the public and practitioners about emergency contraception.
Planetarium Inversum -- a space vision for Earth education.
Lotsch, B
2003-01-01
In a planetarium, the visitor is sitting on Earth and looking into an imaginary space. The Planetarium Inversum is the opposite: visitors are sitting in a space station, looking down on Mother Earth. It is a scientifically-based information show with visitors involvement, its elements being partially virtual (Earth in space has to be projected with highest possible resolution) but also containing real structures, such as the visitors' Earth observatory with adjacent biological systems (plant cultures and other ecological life support components). Its main message concerns the limits and the vulnerability of our home planet, its uniqueness, beauty and above all, its irreplaceableness: Earth does not have an emergency exit. The Earth observatory is part of a ring shaped, rotating space station of the type designed by Wernher von Braun decades ago. Visitors are told that gravity is being substituted by centrifugal force. Both types of life support systems are being demonstrated--self regenerative life based ones and technical ones as a backup (solar electric splitting of water and chemical absorption of respiratory CO2). c2003 COSPAR. Published by Elsevier Science Ltd. All rights reserved.
[Aviation medicine laboratory of the North Fleet air base celebrates the 70th anniversary].
Gavrilov, V V; Mazaĭkin, D N; Buldakov, I M; Pisarev, A A
2013-05-01
The article is dedicated to the history of formation and development of the oldest aviation medicine department and its role in a flight safety of the North Fleet naval aviation. The aviation medicine laboratory was created in the years of the Great Patriotic war for medical backup of flights, medical review board, delivering of combat casualty care, prophylaxis of hypothermia and exhaustion of flight and ground crew. In a post-war period the aviation medicine laboratory made a great contribution to development of medical backup of educational and combat activity of the North Fleet aviation. Participation in cosmonaut applicants selection (incl. Yu.A. Gagarin), optimization of flight services during the transmeridian flights, research of carrier-based aircraft habitability and body state of the contingent during the longstanding ship-based aviation, development of treatment methods for functional status of sea-based aviation crew are the achievements of aviation medicine laboratory. Nowadays medicine laboratory is performing a research and practice, methodic and consultative activity with the aim of improving the system of medical backup, aviation medicine, psychology, flight safety, improvement of air crew health, prolong of flying proficiency.
2004-09-17
AeroVironment's test director Jim Daley, backup pilot Rik Meininger, stability and controls engineer Derek Lisoski and pilot Wyatt Sadler (clockwise from bottom left) closely monitor systems testing of the Pathfinder-Plus solar aircraft from the control station.
How Do I Start a Property Records System?
ERIC Educational Resources Information Center
Whyman, Wynne
2003-01-01
A property records system organizes data to be utilized by a camp's facilities department and integrated into other areas. Start by deciding what records to keep and allotting the time. Then develop consistent procedures, including organizing data, creating a catalog, making back-up copies, and integrating procedures. Use software tools. A good…
Log-less metadata management on metadata server for parallel file systems.
Liao, Jianwei; Xiao, Guoqiang; Peng, Xiaoning
2014-01-01
This paper presents a novel metadata management mechanism on the metadata server (MDS) for parallel and distributed file systems. In this technique, the client file system backs up the sent metadata requests, which have been handled by the metadata server, so that the MDS does not need to log metadata changes to nonvolatile storage for achieving highly available metadata service, as well as better performance improvement in metadata processing. As the client file system backs up certain sent metadata requests in its memory, the overhead for handling these backup requests is much smaller than that brought by the metadata server, while it adopts logging or journaling to yield highly available metadata service. The experimental results show that this newly proposed mechanism can significantly improve the speed of metadata processing and render a better I/O data throughput, in contrast to conventional metadata management schemes, that is, logging or journaling on MDS. Besides, a complete metadata recovery can be achieved by replaying the backup logs cached by all involved clients, when the metadata server has crashed or gone into nonoperational state exceptionally.
Log-Less Metadata Management on Metadata Server for Parallel File Systems
Xiao, Guoqiang; Peng, Xiaoning
2014-01-01
This paper presents a novel metadata management mechanism on the metadata server (MDS) for parallel and distributed file systems. In this technique, the client file system backs up the sent metadata requests, which have been handled by the metadata server, so that the MDS does not need to log metadata changes to nonvolatile storage for achieving highly available metadata service, as well as better performance improvement in metadata processing. As the client file system backs up certain sent metadata requests in its memory, the overhead for handling these backup requests is much smaller than that brought by the metadata server, while it adopts logging or journaling to yield highly available metadata service. The experimental results show that this newly proposed mechanism can significantly improve the speed of metadata processing and render a better I/O data throughput, in contrast to conventional metadata management schemes, that is, logging or journaling on MDS. Besides, a complete metadata recovery can be achieved by replaying the backup logs cached by all involved clients, when the metadata server has crashed or gone into nonoperational state exceptionally. PMID:24892093
Onsite and Electric Backup Capabilities at Critical Infrastructure Facilities in the United States
DOE Office of Scientific and Technical Information (OSTI.GOV)
Phillips, Julia A.; Wallace, Kelly E.; Kudo, Terence Y.
2016-04-01
The following analysis, conducted by Argonne National Laboratory’s (Argonne’s) Risk and Infrastructure Science Center (RISC), details an analysis of electric power backup of national critical infrastructure as captured through the Department of Homeland Security’s (DHS’s) Enhanced Critical Infrastructure Program (ECIP) Initiative. Between January 1, 2011, and September 2014, 3,174 ECIP facility surveys have been conducted. This study focused first on backup capabilities by infrastructure type and then expanded to infrastructure type by census region.
Apollo 11 - Prime and Backup Crews - Geology Training - TX
1969-03-03
S69-25199 (25 Feb. 1969) --- Two Apollo 11 astronauts study a rock specimen during a geological field trip to the Quitman Mountains area near the Fort Quitman ruins in far west Texas. On the left is James A. Lovell Jr., Apollo 11 backup crew commander; and on the right is Fred W. Haise Jr., backup crew lunar module pilot. Lovell holds a camera which was used in simulating taking pictures of actual lunar samples on the surface of the Moon.
Solar-heating and cooling system design package
NASA Technical Reports Server (NTRS)
1980-01-01
Package of information includes design data, performance specifications, drawings, hazard analysis, and spare parts list for commercially produced system installed in single-family dwelling in Akron, Ohio. System uses air flat-plate collectors, 12000 kg rock storage and backup heat pump. Solar portion requires 0.7 kW, and provides 35% of average total heating load including hot water. Information aids persons considering installing solar home-heating systems.
Development of a TL-3 deep beam tubular backup bridge rail.
DOT National Transportation Integrated Search
2010-12-01
The objective of this study is to investigate the performance of the Ohio Department of Transportation (ODOT) Deep Beam bridge rail system per the National Cooperative Highway Research Program (NCHRP) Report 350 TL-3. Analytical study, computer simul...
Reissuance of Position on the Use of Emergency Backup Generators During Power Shortage
This document may be of assistance in applying the Title V air operating permit regulations. This document is part of the Title V Policy and Guidance Database available at www2.epa.gov/title-v-operating-permits/title-v-operating-permit-policy-and-guidance-document-index. Some documents in the database are a scanned or retyped version of a paper photocopy of the original. Although we have taken considerable effort to quality assure the documents, some may contain typographical errors. Contact the office that issued the document if you need a copy of the original.
2001-11-07
KENNEDY SPACE CENTER, Fla. - Astronaut E. Michael Fincke is ready to practice driving an M-113 armored personnel carrier. Fincke is a backup crew member for the International Space Station Expedition 4 crew, who are flying on Space Shuttle Endeavour as part of mission STS-108. Both the mission crew and Expedition 4 crews are at KSC for Terminal Countdown Demonstration Test activities. The TCDT includes emergency exit from the launch pad and a simulated launch countdown. The 11-day mission will also carry the Multi-Purpose Logistics Module Raffaello, filled with supplies and equipment. STS-108 is scheduled to launch Nov. 29
Clarification of EPA's Position on the Use of Emergency Backup Generators During Power Shortage
This document may be of assistance in applying the Title V air operating permit regulations. This document is part of the Title V Policy and Guidance Database available at www2.epa.gov/title-v-operating-permits/title-v-operating-permit-policy-and-guidance-document-index. Some documents in the database are a scanned or retyped version of a paper photocopy of the original. Although we have taken considerable effort to quality assure the documents, some may contain typographical errors. Contact the office that issued the document if you need a copy of the original.
STS-55 German payload specialists and backups pose in front of SL-D2 at KSC
NASA Technical Reports Server (NTRS)
1992-01-01
STS-55 Columbia, Orbiter Vehicle (OV) 102, German payload specialists and backup (alternate) payload specialists pose in front of the Spacelab Deutsche 2 (SL-D2) science module at a Kennedy Space Center (KSC) processing facility. These four Germans have been assigned to support the STS-55/SL-D2 mission. Left to right are Payload Specialist 2 Hans Schlegel, backup Payload Specialist Dr. P. Gerhard Thiele (kneeling), Payload Specialist 1 Ulrich Walter, and backup Payload Specialist Renate Brummer. Walter and Schlegel are scheduled to fly aboard OV-102 for the mission while Brummer and Thiele will serve as alternates and fill supportive roles on the ground. Clearly visible on the SL-D2 module are the European Space Agency (ESA) insignia, the feedthrough plate, and the D2 insignia.
Cold-end Subsystem Testing for the Fission Power System Technology Demonstration Unit
NASA Technical Reports Server (NTRS)
Briggs, Maxwell; Gibson, Marc; Ellis, David; Sanzi, James
2013-01-01
The Fission Power System (FPS) Technology Demonstration Unit (TDU) consists of a pumped sodium-potassium (NaK) loop that provides heat to a Stirling Power Conversion Unit (PCU), which converts some of that heat into electricity and rejects the waste heat to a pumped water loop. Each of the TDU subsystems is being tested independently prior to full system testing at the NASA Glenn Research Center. The pumped NaK loop is being tested at NASA Marshall Space Flight Center; the Stirling PCU and electrical controller are being tested by Sunpower Inc.; and the pumped water loop is being tested at Glenn. This paper describes cold-end subsystem setup and testing at Glenn. The TDU cold end has been assembled in Vacuum Facility 6 (VF 6) at Glenn, the same chamber that will be used for TDU testing. Cold-end testing in VF 6 will demonstrate functionality; validated cold-end fill, drain, and emergency backup systems; and generated pump performance and system pressure drop data used to validate models. In addition, a low-cost proof-of concept radiator has been built and tested at Glenn, validating the design and demonstrating the feasibility of using low-cost metal radiators as an alternative to high-cost composite radiators in an end-to-end TDU test.
Cold-End Subsystem Testing for the Fission Power System Technology Demonstration Unit
NASA Technical Reports Server (NTRS)
Briggs, Mazwell; Gibson, Marc; Ellis, David; Sanzi, James
2013-01-01
The Fission Power System (FPS) Technology Demonstration Unit (TDU) consists of a pumped sodiumpotassium (NaK) loop that provides heat to a Stirling Power Conversion Unit (PCU), which converts some of that heat into electricity and rejects the waste heat to a pumped water loop. Each of the TDU subsystems is being tested independently prior to full system testing at the NASA Glenn Research Center. The pumped NaK loop is being tested at NASA Marshall Space Flight Center; the Stirling PCU and electrical controller are being tested by Sunpower Inc.; and the pumped water loop is being tested at Glenn. This paper describes cold-end subsystem setup and testing at Glenn. The TDU cold end has been assembled in Vacuum Facility 6 (VF 6) at Glenn, the same chamber that will be used for TDU testing. Cold-end testing in VF 6 will demonstrate functionality; validated coldend fill, drain, and emergency backup systems; and generated pump performance and system pressure drop data used to validate models. In addition, a low-cost proof-of concept radiator has been built and tested at Glenn, validating the design and demonstrating the feasibility of using low-cost metal radiators as an alternative to highcost composite radiators in an end-to-end TDU test.
Verni, Christina
2012-08-01
This case study explores the lessons learned when the North Shore-Long Island Jewish Health System, a large, integrated health network in New York, evacuated three hospitals at high risk of flooding from Hurricane Irene in August 2011. The episode resulted in the evacuation, transport, and placement of 947 patients without any resulting deaths or serious injuries. This case demonstrates the utility of having in place a functional evacuation plan, such as the one North Shore-Long Island Jewish Health System developed through its own full-scale exercises in the years following Hurricane Katrina in 2005. In those drills, the health system discovered that it needed to abandon its 1:1 matching of patients to available beds in the region in favor of the group transport of patients with similar needs to facilities that could accommodate them. Despite its overall success, the system identified the need for internal improvements, including automated patient tracking through the use of bar-coded wristbands and identification and training of additional backup personnel for its emergency operations center. Among other changes, policy makers at the state and federal levels should consider mandating full-scale interfacility evacuation drills to refine mechanisms to send and receive patients.
Kollipara, Ramya; Peranteau, Andrew J; Nawas, Zeena Y; Tong, Yun; Woc-Colburn, Laila; Yan, Albert C; Lupi, Omar; Tyring, Stephen K
2016-07-01
Given increased international travel, immigration, changing climate conditions, and the increased incidence of iatrogenic immunosuppression, fungal, protozoan, helminthic, and ectoparasitic infections that were once uncommon are being seeing more frequently in the Western hemisphere. However, the diagnosis and management of these infections is fraught with a lack of consistency because there is a dearth of dermatology literature on the cutaneous manifestations of these infections. In addition, delays in the diagnosis and treatment of these diseases can lead to significant patient morbidity and mortality. We review the epidemiology, cutaneous manifestations, diagnostic modalities, and treatment options for emerging fungal, protozoan, helminthic, and ectoparasitic infections. It should be noted, however, that throughout this review we cite statistics documenting their increased incidence to back-up these infections as emerging, and although some of the diagnoses are clinical, others rely on newer laboratory tests, and the possibility exists that the increased incidence could be caused by better detection methods. Copyright © 2016 American Academy of Dermatology, Inc. Published by Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
1989-01-01
Rayovac Corporation's Luma 2 flashlight incorporates NASA's systems redundancy. The company also received assistance from NERAC. The flashlight has an extra-bright Super Krypton primary bulb and an independent backup system including a separate lithium power cell (a NASA developed technology), its own bulb and switch with corrosion proof sealed contacts. NERAC has also assisted Rayovac in developing other products.
Savings and load reaps passive solar dividends
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1979-06-01
A wood-burning fireplace is the main backup heating system at the Friendship Federal Savings and Loan office in Butler, Pennsylvania. The solar design consists of a passive system in which a concrete block wall serves as the energy collector for the building. A 14-square meter skylight over part of the main banking lobby provides additional solar energy. (MCW)
Fac-Back-OPAC: An Open Source Interface to Your Library System
ERIC Educational Resources Information Center
Beccaria, Mike; Scott, Dan
2007-01-01
The new Fac-Back-OPAC (a faceted backup OPAC) is built on code that was originally developed by Casey Durfee in February 2007. It represents the convergence of two prominent trends in library tools: the decoupling of discovery tools from the traditional integrated library system (ILS) and the use of readily available open source components to…
What's in Your Techno-Future? Vendors Share Their Views.
ERIC Educational Resources Information Center
Gerber, Carole
1995-01-01
Examines vendors' views on the future of CD-ROM technology. Topics include the library role, single point access, costs, tape backup, user-friendly library automation systems and databases, improved quality, the growth of Internet access, and perspectives on technology in schools. (AEF)
AN ELECTROSTATIC PRECIPITATOR BACKUP FOR SAMPLING SYSTEMS
The report describes a program carried out to design and evaluate the performance of an electrostatic collector to be used as an alternative to filters as a fine particle collector. Potential advantages of an electrostatic precipitator are low pressure drop and high capacity. Pot...
Backing warning sensors for tow plows.
DOT National Transportation Integrated Search
2013-06-01
Backup warning system devices were evaluated to determine if they would alert winter maintenance snow : plow drivers to obstacles directly behind the trailer and out of view of the driver when a unit is backed up. : When the sensors on the back of th...
Guidelines for traffic signal energy back-up systems : final report, August 2009.
DOT National Transportation Integrated Search
2009-07-01
Current practices of responding to power failures are very basic, ranging from 'do nothing' to installing portable generators. The purpose of this research project was to provide the NYSDOT with a better understand the practices of other agencies in ...
DOT Announces Action Plan for Transportation Infrastructure Relying on GPS
DOT National Transportation Integrated Search
2002-03-07
U.S. Transportation Secretary Norman Y. Mineta today announced that the U.S. Department of : Transportation (DOT) will implement an action plan to maintain the adequacy of backup systems : for each area of operation in which the Global Positioning Sy...
STS-55 German payload specialists (and backups) in LESs during JSC training
NASA Technical Reports Server (NTRS)
1992-01-01
STS-55 Columbia, Orbiter Vehicle (OV) 102, German payload specialists and backup (alternate) payload specialists, wearing launch and entry suits (LESs), pose for group portrait outside mockup side hatch in JSC's Mockup and Integration Laboratory (MAIL) Bldg 9NE. These payload specialists will support the STS-55 Spacelab Deutsche 2 (SL-D2) mission. It is the second dedicated German (Deutsche) Spacelab flight. Left to right are backup Payload Specialists Renate Brummer and Dr. P. Gerhard Thiele, Payload Specialist 1 Ulrich Walter, and Payload Specialist 2 Hans Schlegel.
STS-47 Payload Specialist Mohri and Japanese backups pose in SLJ module at KSC
NASA Technical Reports Server (NTRS)
1992-01-01
STS-47 payload specialists representing Japan's National Space Development Agency (NASDA) examine the interior of the Spacelab Japan (SLJ) laboratory module recently installed in Endeavour's, Orbiter Vehicle (OV) 105's, payload bay (PLB). Left to right are Payload Specialist Mamoru Mohri, backup Payload Specialist Chiaki Naito-Mukai, and backup Payload Specialist Takao Doi. The crewmembers visited OV-105, currently undergoing preflight processing in a high bay area of Kennedy Space Center's (KSC's) Orbiter Processing Facility (OPF). View provided by KSC with alternate KSC number KSC-92PC-1649.
View of backup payload specialist Robert Thirsk during Zero-G training
1984-07-16
S84-37532 (18 July 1984) --? Robert B. Thirsk, backup payload specialist for 41-G appears to be shaking hands with an unoccupied extravehicular mobility unit (EMU) during a familiarization flight aboard NASA?s KC-135 aircraft. Thirsk, representing Canada?s National Research Council (NRC), serves as backup to Marc Garneau on the seven-member crew for Challenger?s October 1984 flight. This aircraft is used extensively for training and exposing Shuttle crewmembers to weightlessness as well as for evaluation of equipment and experiments scheduled for future flights.
2014-09-01
efficient yet safe operations. • Further understanding of human psychology in the operation of autonomous systems. • Interfaces, be they visual...that system, especially when included in aspects or during times where automation backup is required, when the human-operators anticipatory skills...political and psychological domains, where it connotes self-determination (Christman 2009). The autonomous systems domain that has evolved since
Murti, Michelle; Bayleyegn, Tesfaye; Stanbury, Martha; Flanders, William Dana; Yard, Ellen; Nyaku, Mawuli; Wolkin, Amy
2014-02-01
We examined the association between housing type and household emergency preparedness among households in Oakland County, Michigan. We used interview data on household emergency preparedness from a cluster design survey in Oakland County, Michigan, in 2012. We compared survey-weighted frequencies of household demographics, medical conditions, and preparedness measures in single-detached homes versus multi-unit dwellings, and determined the unadjusted odds ratios (OR) and the income-level adjusted OR for each preparedness measure. Households had similar demographics and medical conditions between housing types. Unadjusted ORs were statistically significant for single detached homes having a generator (11.1), back-up heat source (10.9), way to cook without utilities (5.8), carbon monoxide (CO) detector (3.8), copies of important documents (3.4), evacuation routes (3.1), and 3-day supply of water (2.5). Income level adjusted ORs remained statistically significant except for owning a CO detector. Households in multi-unit dwellings were less likely to have certain recommended emergency plans and supplies compared to those in single detached homes. Further research is required to explore the feasibility, barriers, and alternatives for households in multi-unit dwellings in terms of complying with these measures.
Water electrolysis system refurbishment and testing
NASA Technical Reports Server (NTRS)
Greenough, B. M.
1972-01-01
The electrolytic oxygen generator for the back-up water electrolysis system in a 90-day manned test was refurbished, improved and subjected to a 182-day bench test. The performance of the system during the test demonstrated the soundness of the basic electrolysis concept, the high development status of the automatic controls which allowed completely hands-off operation, and the capability for orbital operation. Some design improvements are indicated.
Alkali Metal Backup Cooling for Stirling Systems - Experimental Results
NASA Technical Reports Server (NTRS)
Schwendeman, Carl; Tarau, Calin; Anderson, William G.; Cornell, Peggy A.
2013-01-01
In a Stirling Radioisotope Power System (RPS), heat must be continuously removed from the General Purpose Heat Source (GPHS) modules to maintain the modules and surrounding insulation at acceptable temperatures. The Stirling convertor normally provides this cooling. If the Stirling convertor stops in the current system, the insulation is designed to spoil, preventing damage to the GPHS at the cost of an early termination of the mission. An alkali-metal Variable Conductance Heat Pipe (VCHP) can be used to passively allow multiple stops and restarts of the Stirling convertor. In a previous NASA SBIR Program, Advanced Cooling Technologies, Inc. (ACT) developed a series of sodium VCHPs as backup cooling systems for Stirling RPS. The operation of these VCHPs was demonstrated using Stirling heater head simulators and GPHS simulators. In the most recent effort, a sodium VCHP with a stainless steel envelope was designed, fabricated and tested at NASA Glenn Research Center (GRC) with a Stirling convertor for two concepts; one for the Advanced Stirling Radioisotope Generator (ASRG) back up cooling system and one for the Long-lived Venus Lander thermal management system. The VCHP is designed to activate and remove heat from the stopped convertor at a 19 C temperature increase from the nominal vapor temperature. The 19 C temperature increase from nominal is low enough to avoid risking standard ASRG operation and spoiling of the Multi-Layer Insulation (MLI). In addition, the same backup cooling system can be applied to the Stirling convertor used for the refrigeration system of the Long-lived Venus Lander. The VCHP will allow the refrigeration system to: 1) rest during transit at a lower temperature than nominal; 2) pre-cool the modules to an even lower temperature before the entry in Venus atmosphere; 3) work at nominal temperature on Venus surface; 4) briefly stop multiple times on the Venus surface to allow scientific measurements. This paper presents the experimental results from integrating the VCHP with an operating Stirling convertor and describes the methodology used to achieve their successful combined operation.
Alkali Metal Backup Cooling for Stirling Systems - Experimental Results
NASA Technical Reports Server (NTRS)
Schwendeman, Carl; Tarau, Calin; Anderson, William G.; Cornell, Peggy A.
2013-01-01
In a Stirling Radioisotope Power System (RPS), heat must be continuously removed from the General Purpose Heat Source (GPHS) modules to maintain the modules and surrounding insulation at acceptable temperatures. The Stirling convertor normally provides this cooling. If the Stirling convertor stops in the current system, the insulation is designed to spoil, preventing damage to the GPHS at the cost of an early termination of the mission. An alkali-metal Variable Conductance Heat Pipe (VCHP) can be used to passively allow multiple stops and restarts of the Stirling convertor. In a previous NASA SBIR Program, Advanced Cooling Technologies, Inc. (ACT) developed a series of sodium VCHPs as backup cooling systems for Stirling RPS. The operation of these VCHPs was demonstrated using Stirling heater head simulators and GPHS simulators. In the most recent effort, a sodium VCHP with a stainless steel envelope was designed, fabricated and tested at NASA Glenn Research Center (GRC) with a Stirling convertor for two concepts; one for the Advanced Stirling Radioisotope Generator (ASRG) back up cooling system and one for the Long-lived Venus Lander thermal management system. The VCHP is designed to activate and remove heat from the stopped convertor at a 19 degC temperature increase from the nominal vapor temperature. The 19 degC temperature increase from nominal is low enough to avoid risking standard ASRG operation and spoiling of the Multi-Layer Insulation (MLI). In addition, the same backup cooling system can be applied to the Stirling convertor used for the refrigeration system of the Long-lived Venus Lander. The VCHP will allow the refrigeration system to: 1) rest during transit at a lower temperature than nominal; 2) pre-cool the modules to an even lower temperature before the entry in Venus atmosphere; 3) work at nominal temperature on Venus surface; 4) briefly stop multiple times on the Venus surface to allow scientific measurements. This paper presents the experimental results from integrating the VCHP with an operating Stirling convertor and describes the methodology used to achieve their successful combined operation.
RELAP5-3D Resolution of Known Restart/Backup Issues
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mesina, George L.; Anderson, Nolan A.
2014-12-01
The state-of-the-art nuclear reactor system safety analysis computer program developed at the Idaho National Laboratory (INL), RELAP5-3D, continues to adapt to changes in computer hardware and software and to develop to meet the ever-expanding needs of the nuclear industry. To continue at the forefront, code testing must evolve with both code and industry developments, and it must work correctly. To best ensure this, the processes of Software Verification and Validation (V&V) are applied. Verification compares coding against its documented algorithms and equations and compares its calculations against analytical solutions and the method of manufactured solutions. A form of this, sequentialmore » verification, checks code specifications against coding only when originally written then applies regression testing which compares code calculations between consecutive updates or versions on a set of test cases to check that the performance does not change. A sequential verification testing system was specially constructed for RELAP5-3D to both detect errors with extreme accuracy and cover all nuclear-plant-relevant code features. Detection is provided through a “verification file” that records double precision sums of key variables. Coverage is provided by a test suite of input decks that exercise code features and capabilities necessary to model a nuclear power plant. A matrix of test features and short-running cases that exercise them is presented. This testing system is used to test base cases (called null testing) as well as restart and backup cases. It can test RELAP5-3D performance in both standalone and coupled (through PVM to other codes) runs. Application of verification testing revealed numerous restart and backup issues in both standalone and couple modes. This document reports the resolution of these issues.« less
Backup Warning Signals: Driver Perception and Response
DOT National Transportation Integrated Search
1996-08-01
This report describes the findings of three experiments that concern driver reaction to acoustic signals that might be used for backup warning devices. Intelligent warning devices are under development that will use vehicle-based sensors to warn back...
Official portrait of STS-65 backup Payload Specialist Jean-Jacques Favier
1993-09-30
Official portrait of STS-65 International Microgravity Laboratory 2 (IML-2) backup Payload Specialist Jean-Jacques Favier. Favier is a member of the Centre National D'Etudes Spatiales (CNES), the French space agency.
NASA Astrophysics Data System (ADS)
Zhang, Guimin; Li, Yinping; Daemen, Jaak J. K.; Yang, Chunhe; Wu, Yu; Zhang, Kai; Chen, Yanlong
2015-09-01
The lower reaches of the Yangtze River is one of the most developed regions in China. It is desirable to build compressed air energy storage (CAES) power plants in this area to ensure the safety, stability, and economic operation of the power network. Geotechnical feasibility analysis was carried out for CAES in impure bedded salt formations in Huai'an City, China, located in this region. First, geological investigation revealed that the salt groups in the Zhangxing Block meet the basic geological conditions for CAES storage, even though the possible unfavorable characteristics of the salt formations include bedding and different percentages of impurities. Second, mechanical tests were carried out to determine the mechanical characteristics of the bedded salt formations. It is encouraging that the samples did not fail even when they had undergone large creep deformation. Finally, numerical simulation was performed to evaluate the stability and volume shrinkage of the CAES under the following conditions: the shape of a single cavern is that of a pear; the width of the pillar is adopted as two times the largest diameter; three regular operating patterns were adopted for two operating caverns (internal pressure 9-10.5 MPa, 10-11.5 MPa, and 11-12.5 MPa), while the other two were kept at high pressure (internal pressure 10.5, 11.5, and 12.5 MPa) as backups; an emergency operating pattern in which two operating caverns were kept at atmospheric pressure (0.1 MPa) for emergency while the backups were under operation (9-10.5 MPa), simulated for 12 months at the beginning of the 5th year. The results of the analysis for the plastic zone, displacement, and volume shrinkage support the feasibility of the construction of an underground CAES power station.
NASA Astrophysics Data System (ADS)
Wohland, Jan; Reyers, Mark; Weber, Juliane; Witthaut, Dirk
2017-11-01
Limiting anthropogenic climate change requires the fast decarbonization of the electricity system. Renewable electricity generation is determined by the weather and is hence subject to climate change. We simulate the operation of a coarse-scale fully renewable European electricity system based on downscaled high-resolution climate data from EURO-CORDEX. Following a high-emission pathway (RCP8.5), we find a robust but modest increase (up to 7 %) of backup energy in Europe through the end of the 21st century. The absolute increase in the backup energy is almost independent of potential grid expansion, leading to the paradoxical effect that relative impacts of climate change increase in a highly interconnected European system. The increase is rooted in more homogeneous wind conditions over Europe resulting in intensified simultaneous generation shortfalls. Individual country contributions to European generation shortfall increase by up to 9 TWh yr-1, reflecting an increase of up to 4 %. Our results are strengthened by comparison with a large CMIP5 ensemble using an approach based on circulation weather types.
Methods to assess carbonaceous aerosol sampling artifacts for IMPROVE and other long-term networks.
Watson, John G; Chow, Judith C; Chen, L W Antony; Frank, Neil H
2009-08-01
Volatile organic compounds (VOCs) and semi-volatile organic compounds (SVOCs) adsorb to quartz fiber filters during fine and coarse particulate matter (PM2.5 and PM10, respectively) sampling for thermal/optical carbon analysis that measures organic carbon (OC) and elemental carbon (EC). Particulate SVOCs can evaporate after collection, with a small portion adsorbed within the filter. Adsorbed organic gases are measured as particulate OC, so passive field blanks, backup filters, prefilter organic denuders, and regression methods have been applied to compensate for positive OC artifacts in several long-term chemical speciation networks. Average backup filter OC levels from the Interagency Monitoring of Protected Visual Environments (IMPROVE) network were approximately 19% higher than field blank values. This difference is within the standard deviation of the average and likely results from low SVOC concentrations in the rural to remote environments of most IMPROVE sites. Backup filters from an urban (Fort Meade, MD) site showed twice the OC levels of field blanks. Sectioning backup filters from top to bottom showed nonuniform OC densities within the filter, contrary to the assumption that VOCs and SVOCs on a backup filter equal those on the front filter. This nonuniformity may be partially explained by evaporation and readsorption of vapors in different parts of the front and backup quartz fiber filter owing to temperature, relative humidity, and ambient concentration changes throughout a 24-hr sample duration. OC-PM2.5 regression analysis and organic denuder approaches demonstrate negative sampling artifact from both Teflon membrane and quartz fiber filters.
Optimization of robustness of interdependent network controllability by redundant design
2018-01-01
Controllability of complex networks has been a hot topic in recent years. Real networks regarded as interdependent networks are always coupled together by multiple networks. The cascading process of interdependent networks including interdependent failure and overload failure will destroy the robustness of controllability for the whole network. Therefore, the optimization of the robustness of interdependent network controllability is of great importance in the research area of complex networks. In this paper, based on the model of interdependent networks constructed first, we determine the cascading process under different proportions of node attacks. Then, the structural controllability of interdependent networks is measured by the minimum driver nodes. Furthermore, we propose a parameter which can be obtained by the structure and minimum driver set of interdependent networks under different proportions of node attacks and analyze the robustness for interdependent network controllability. Finally, we optimize the robustness of interdependent network controllability by redundant design including node backup and redundancy edge backup and improve the redundant design by proposing different strategies according to their cost. Comparative strategies of redundant design are conducted to find the best strategy. Results shows that node backup and redundancy edge backup can indeed decrease those nodes suffering from failure and improve the robustness of controllability. Considering the cost of redundant design, we should choose BBS (betweenness-based strategy) or DBS (degree based strategy) for node backup and HDF(high degree first) for redundancy edge backup. Above all, our proposed strategies are feasible and effective at improving the robustness of interdependent network controllability. PMID:29438426
12 CFR 7.5004 - Sale of excess electronic capacity and by-products.
Code of Federal Regulations, 2010 CFR
2010-01-01
... bank's needs for banking purposes include: (1) Data processing services; (2) Production and distribution of non-financial software; (3) Providing periodic back-up call answering services; (4) Providing full Internet access; (5) Providing electronic security system support services; (6) Providing long...
Solar energy/utility interface - The technical issues
NASA Astrophysics Data System (ADS)
Tabors, R. D.; White, D. C.
1982-01-01
The technical and economic factors affecting an interface between solar/wind power sources and utilities are examined. Photovoltaic, solar thermal, and wind powered systems are subject to stochastic local climatic variations and as such may require full back-up services from utilities, which are then in a position of having reserve generating power and power lines and equipment which are used only part time. The low reliability which has degraded some economies of scale formerly associated with large, centralized power plants, and the lowered rate of the increase in electricity usage is taken to commend the inclusion of power sources with a modular nature such as is available from solar derived electrical generation. Technical issues for maintaining the quality of grid power and also effectively metering purchased and supplied back-up power as part of a homeostatic system of energy control are discussed. It is concluded that economic considerations, rather than technical issues, bear the most difficulty in integrating solar technologies into the utility network.
2011-01-01
Background Prehospital advanced airway management, including prehospital endotracheal intubation is challenging and recent papers have addressed the need for proper training, skill maintenance and quality control for emergency medical service personnel. The aim of this study was to provide data regarding airway management-training and expertise from the regional physician-staffed emergency medical service (EMS). Methods The EMS in this part of The Central Region of Denmark is a two tiered system. The second tier comprises physician staffed Mobile Emergency Care Units. The medical directors of the programs supplied system data. A questionnaire addressing airway management experience, training and knowledge was sent to the EMS-physicians. Results There are no specific guidelines, standard operating procedures or standardised program for obtaining and maintaining skills regarding prehospital advanced airway management in the schemes covered by this study. 53/67 physicians responded; 98,1% were specialists in anesthesiology, with an average of 17,6 years of experience in anesthesiology, and 7,2 years experience as EMS-physicians. 84,9% reported having attended life support course(s), 64,2% an advanced airway management course. 24,5% fulfilled the curriculum suggested for Danish EMS physicians. 47,2% had encountered a difficult or impossible PHETI, most commonly in a patient in cardiac arrest or a trauma patient. Only 20,8% of the physicians were completely familiar with what back-up devices were available for airway management. Conclusions In this, the first Danish study of prehospital advanced airway management, we found a high degree of experience, education and training among the EMS-physicians, but their equipment awareness was limited. Check-outs, guidelines, standard operating procedures and other quality control measures may be needed. PMID:21303510
Emergency seismic and CGPS networks: a first employment for the L'Aquila Mw 6.3 earthquake
NASA Astrophysics Data System (ADS)
Abruzzese, L.; Avallone, A.; Cecere, G.; Cattaneo, M.; Cardinale, V.; Castagnozzi, A.; Cogliano, R.; Criscuoli, F.; D'Agostino, N.; D'Ambrosio, C.; de Luca, G.; D'Anastasio, E.; Falco, L.; Flammia, V.; Migliari, F.; Minichiello, F.; Memmolo, A.; Monachesi, G.; Moschillo, R.; Pignone, M.; Pucillo, S.; Selvaggi, G.; Zarrilli, L.; Delladio, A.; Govoni, A.; Franceschi, D.; de Martin, M.; Moretti, M.
2009-12-01
During the last 2 years, the Istituto Nazionale di Geofisica e Vulcanologia (INGV) developed an important real-time temporary seismic network infrastructure in order to densify the Italian National Seismic Network in epicentral areas thus enhancing the localization of the micro-seismicity after main earthquake events. This real-time temporary seismic network is constituted by various mobile and autonomous seismic stations that in group of three are telemetered to a Very Small Aperture Terminal (VSAT). This system uses a dedicated bandwidth on UHF, Wi-Fi and satellite frequency that allows the data flow in real-time at INGV centre in Rome (and Grottaminarda as backup center). The deployment of the seismic network is managed in a geographical information systems (GIS) by particular scenarios that visualizes, for the epicentral area, information about instrumental seismicity, seismic risk, macroseismic felts and territorial data. Starting from digital terrain model, the surface spatial analysis (Viewshed, Observer Point) allows the geographic arrangement of the stations and relative scenarios. The April, 6th, 2009 Mw 6.3 L'Aquila destructive earthquake represented the first real-case to test the entire emergency seismic network infrastructure. Less than 6 hours after the earthquake occurrence, a first accelerometer station was already sending data at INGV seismic monitoring headquarters. A total number of 9 seismic stations have been installed within 3 days after the earthquake. Furthermore, 5 permanent GPS stations have been installed in the epicentral area within 1 to 9 days after the main shock to detect the post-seismic deformation induced by the earthquake. We will show and describe the details of the Emergency Seismic Network infrastructure, and the first results from the collected data.
Connectivity services based on optical ground-to-space links
NASA Astrophysics Data System (ADS)
Knopp, Marcus T.; Giggenbach, Dirk; Mata Calvo, Ramon; Fuchs, Christian; Saucke, Karen; Heine, Frank; Sellmaier, Florian; Huber, Felix
2018-07-01
Repeater systems in a geostationary orbit utilizing free-space optical-communication offer great potential to backup, process and archive large amounts of data collected or generated at remote locations. In contrast to existing or upcoming global satellite communication systems, such optical GEO relays are able to provide a huge return-channel data throughput with channel rates in the gigabit-per-second range. One of the most critical aspects of such data uplinks are atmospheric disturbances above the optical ground terminals used to connect to the space segment. In this study, we analyse the design drivers of optical ground stations for land-based applications. In particular, the effects of atmospheric attenuation and atmospheric turbulence are investigated. Moreover, we present implementation ideas of the necessary ground infrastructure and exemplify our results in a case study on the applicability of free-space optical satellite communication to the radio astronomy community. Our survey underpins pre-existing ventures to foster optical relay services like the Space-Data-Highway operating via the European Data Relay System. With well-designed, self-sufficient and small-sized ground terminals new user groups could be attracted, by offering alternatives to the emerging LEO mega-constellations and GEO-satellite communication systems, which operate at low return channel data rates across-the-board.
Low Velocity Airdrop Tests of an X-38 Backup Parachute Design
NASA Technical Reports Server (NTRS)
Stein, Jenny M.; Machin, Ricardo A.; Wolf, Dean F.; Hillebrandt, F. David
2007-01-01
The NASA Johnson Space Center's X-38 program designed a new backup parachute system to recover the 25,000 lb X-38 prototype for the Crew Return Vehicle spacecraft. Due to weight and cost constraints, the main backup parachute design incorporated rapid and low cost fabrication techniques using off-the-shelf materials. Near the vent, the canopy was constructed of continuous ribbons, to provide more damage tolerance. The remainder of the canopy was a constructed with a continuous ringslot design. After cancellation of the X-38 program, the parachute design was resized, built, and drop tested for Natick Soldiers Center's Low Velocity Air Drop (LVAD) program to deliver cargo loads up to 22,000 lbs from altitudes as low as 500 feet above the ground. Drop tests results showed that the 500-foot LVAD parachute deployment conditions cause severe skirt inversion and inflation problems for large parachutes. The bag strip occurred at a high angle of attack, causing skirt inversion before the parachute could inflate. The addition of a short reefing line prevented the skirt inversion. Using a lower porosity in the vent area, than is normally used in large parachutes, improved inflation. The drop testing demonstrated that the parachute design could be refined to meet the requirements for the 500-foot LVAD mission.
Djelmami-Hani, M; Mouanoutoua, Mouatou; Hashim, Abdelazim; Solis, Joaquin; Bergen, Lawrence; Oldridge, Neil; Egbujiobi, Leo C; Allaqaband, Suhail; Akhtar, Masood; Bajwa, Tanvir
2007-12-01
The American College of Cardiology guidelines consider elective percutaneous coronary intervention (PCI) without on-site surgical backup (OSB) a Class-III indication. Our objective was to determine the safety of elective PCI without OSB. The study is a prospective analysis of a cohort of patients who underwent elective PCI without OSB at our institution. All patients were at our community satellite institution in Beloit, Wis. Three hundred twenty-one elective interventions were performed (mean age 64 +/-12, 68% male). The prevalence of diabetes and hypertension was 28% and 82.5% respectively. A predefined protocol was designed to transfer patients to a cardiac surgical facility if necessary. An experienced interventional cardiologist reviewed the diagnostic angiograms. Patients with complex lesions were excluded from the study. Any procedure-related death or emergency coronary artery bypass graft surgery. Three hundred eighty-two vessels were stented. Multi-vessel intervention was performed in 61 patients (19%). Only 5% of lesions were type C. Four hundred thirty-seven stents were deployed. IIb-IIIa inhibitors were used in 77 (24%) cases. Procedural success was 99.7%. There were no deaths, myocardial infarctions nor need for urgent target vessel revascularization at 6 months. With careful patient/lesion selection, an experienced interventional cardiologist and a predefined transfer protocol, elective PCI without OSB can be performed safely.
Mouse Sperm Cryopreservation and Recovery using the I·Cryo Kit
Liu, Ling; Sansing, Steven R.; Morse, Iva S.; Pritchett-Corning, Kathleen R.
2011-01-01
Thousands of new genetically modified (GM) strains of mice have been created since the advent of transgenesis and knockout technologies. Many of these valuable animals exist only as live animals, with no backup plan in case of emergency. Cryopreservation of embryos can provide this backup, but is costly, can be a lengthy procedure, and generally requires a large number of animals for success. Since the discovery that mouse sperm can be successfully cryopreserved with a basic cryoprotective agent (CPA) consisting of 18% raffinose and 3% skim milk, sperm cryopreservation has become an acceptable and cost-effective procedure for archiving, distributing and recovery of these valuable strains. Here we demonstrate a newly developed I•Cryo kit for mouse sperm cryopreservation. Sperm from five commonly-used strains of inbred mice were frozen using this kit and then recovered. Higher protection ratios of sperm motility (> 60%) and rapid progressive motility (> 45%) compared to the control (basic CPA) were seen for sperm frozen with this kit in 5 inbred mouse strains. Two cell stage embryo development after IVF with the recovered sperm was improved consistently in all 5 mouse strains examined. Over a 1.5 year period, 49 GM mouse lines were archived by sperm cryopreservation with the I•Cryo kit and later recovered by IVF. PMID:22214993
Attitude determination with three-axis accelerometer for emergency atmospheric entry
NASA Technical Reports Server (NTRS)
Garcia-Llama, Eduardo (Inventor)
2012-01-01
Two algorithms are disclosed that, with the use of a 3-axis accelerometer, will be able to determine the angles of attack, sideslip and roll of a capsule-type spacecraft prior to entry (at very high altitudes, where the atmospheric density is still very low) and during entry. The invention relates to emergency situations in which no reliable attitude and attitude rate are available. Provided that the spacecraft would not attempt a guided entry without reliable attitude information, the objective of the entry system in such case would be to attempt a safe ballistic entry. A ballistic entry requires three controlled phases to be executed in sequence: First, cancel initial rates in case the spacecraft is tumbling; second, maneuver the capsule to a heat-shield-forward attitude, preferably to the trim attitude, to counteract the heat rate and heat load build up; and third, impart a ballistic bank or roll rate to null the average lift vector in order to prevent prolonged lift down situations. Being able to know the attitude, hence the attitude rate, will allow the control system (nominal or backup, automatic or manual) to cancel any initial angular rates. Also, since a heat-shield forward attitude and the trim attitude can be specified in terms of the angles of attack and sideslip, being able to determine the current attitude in terms of these angles will allow the control system to maneuver the vehicle to the desired attitude. Finally, being able to determine the roll angle will allow for the control of the roll ballistic rate during entry.
Impact of strong climate change on balancing and storage needs in a fully renewable energy system
NASA Astrophysics Data System (ADS)
Weber, Juliane; Wohland, Jan; Witthaut, Dirk
2017-04-01
We investigate the impact of strong climate change on a European energy system dominated by wind power. No robust trend can be observed regarding the change of the wind power yield for most countries in Europe. However, intra-annual variabilities in wind power generation robustly increase in most of Central and Western Europe and decrease in Spain, Portugal and Greece by the end of this century. Thus, the generation of wind power tends to increase (decrease) in the winter months compared to the summer months. Due to higher (lower) intra-annual variations, the probability for extreme events with long periods of low power production increases (decreases) in summer. This implies that more (less) energy has to be provided by backup power plants. Our simulations are based on the results of five different Global Climate Models (GCMs) using the Representative Concentration Pathway scenario 8.5 (RCP8.5). These results are dynamically downscaled with the regional atmospheric model RCA4 by the EURO-CORDEX initiative (Coordinated Downscaling Experiment - European Domain). A comparison was made between historical data (1970-2000) and mid-century (2030-2060) and end-of-century (2070-2100) data, respectively. For all timeframes we made the assumption that a certain amount of energy is provided by wind power plants. This implies that changes in wind power potentials are neglected and only temporal effects are considered. Wind speed time series are converted to power generation time series using an extrapolation to hub height and a standardized power curve. Assuming a scenario for the future distribution of wind turbines, we obtain a wind power generation time series aggregated on a national level. The operation of backup power plants and storage facilities is simulated on coarse scales assuming an optimal storage strategy. Backup is required whenever the storage facilities are empty. The amount of change of the backup energy depends on the storage capacity - the higher the capacity, the higher the change as long as storage capacities do not allow for multi-year storage.
Expedition 9 Preflight Activities
2004-04-13
NASA Expedition 9 backup Commander Leroy Chiao, left and backup European Space Agency astronaut Gerhard Thiele of Germany sign books, envelops and mementoes in the space museum located at the Baikonur Cosmodrome, Wednesday, April, 14, 2004, in Baikonur, Kazakhstan. Photo Credit: (NASA/Bill Ingalls)
STS-47 Japanese Payload Specialist Mohri and backups during Homestead training
NASA Technical Reports Server (NTRS)
1990-01-01
STS-47 Endeavour, Orbiter Vehicle (OV) 105, Japanese Payload Specialist Mamoru Mohri (far left), backup Payload Specialist Takao Doi (center), and backup Payload Specialist Chiaki Mukai (right) participate in water survival training at Homestead Air Force Base, Florida. Dockside, Mohri and Mukai wash the salt water from their personalized helmets after a water exercise. The three-day course was attended by the STS-47 prime and alternate payload specialists shortly after they were announced for the scheduled summer of 1992 Spacelab Japan (SLJ) mission. Mohri, Doi, and Mukai all represent the National Space Development Agency of Japan (NASDA).
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-02
... and were not sold, bartered or traded. At the time, DAS was the only effort control for the FMP, and... current system does not accurately account for the disposition of fish landed under the ``home consumption... receipt of the TSH report via a back-up system specified by the DSM service provider. While the...
Recommended Systems for the Incremental Automation of the Morgue of "The Daily Texan."
ERIC Educational Resources Information Center
Voges, Mickie; And Others
A modular program is recommended for automation of the clippings file of "The Daily Texan" (student newspaper of the University of Texas at Austin). The proposed system will lead ultimately to on-line storage of the index, on-line storage of local, staff-written news stories from the previous twenty-four months, micrographic storage for backup and…
Do familiar teammates request and accept more backup? Transactive memory in air traffic control.
Smith-Jentsch, Kimberly A; Kraiger, Kurt; Cannon-Bowers, Janis A; Salas, Eduardo
2009-04-01
The present study investigated factors that explain when and why different groups of teammates are more likely to request and accept backup from one another when needed in an environment characterized by extreme time pressure and severe consequences of error: commercial air traffic control (ATC). Transactive memory theory states that teammates develop consensus regarding the distribution of their relative expertise as well as confidence in that expertise over time and that this facilitates coordination processes. The present study investigated whether this theory could help to explain between-team differences in requesting and accepting backup when needed. The present study used cross-sectional data collected from 51 commercial ATC teams. Hypotheses were tested using multiple regression analysis. Teammates with greater experience working together requested and accepted backup from one another more than those with lesser experience working together. Teammate knowledge consensus and perceived team efficacy appear to have mediated this relationship. Transactive memory theory extends to high-stress environments in which members' expertise is highly overlapping. Teammates' shared mental models about one another increase the likelihood that they will request and accept backup. Teammate familiarity should be considered when choosing among potential replacement team members. Training strategies that accelerate the development of teammate knowledge consensus and team efficacy are warranted.
NASA Technical Reports Server (NTRS)
Kast, J. R.
1988-01-01
The Upper Atmosphere Research Satellite (UARS) is a three-axis stabilized Earth-pointing spacecraft in a low-Earth orbit. The UARS onboard computer (OBC) uses a Fourier Power Series (FPS) ephemeris representation that includes 42 position and 42 velocity coefficients per axis, with position residuals at 10-minute intervals. New coefficients and 32 hours of residuals are uploaded daily. This study evaluated two backup methods that permit the OBC to compute an approximate spacecraft ephemeris in the event that new ephemeris data cannot be uplinked for several days: (1) extending the use of the FPS coefficients previously uplinked, and (2) switching to a simple circular orbit approximation designed and tested (but not implemented) for LANDSAT-D. The FPS method provides greater accuracy during the backup period and does not require additional ground operational procedures for generating and uplinking an additional ephemeris table. The tradeoff is that the high accuracy of the FPS will be degraded slightly by adopting the longer fit period necessary to obtain backup accuracy for an extended period of time. The results for UARS show that extended use of the FPS is superior to the circular orbit approximation for short-term ephemeris backup.
AFTI/F-111 MAW flight control system and redundancy management description
NASA Technical Reports Server (NTRS)
Larson, Richard R.
1987-01-01
The wing on the NASA F-111 transonic aircraft technology (TACT) airplane was modified to provide flexible leading and trailing edge flaps; this modified wing is known as the mission adaptive wing (MAW). A dual digital primary fly-by-wire flight control system was developed with analog backup reversion for redundancy. This report discusses the functions, design, and redundancy management of the flight control system for these flaps.
2016-09-01
and network. The computing and network hardware are identified and include routers, servers, firewalls, laptops , backup hard drives, smart phones...deployable hardware units will be necessary. This includes the use of ruggedized laptops and desktop computers , a projector system, communications system...ENGINEERING STUDY AND CONCEPT DEVELOPMENT FOR A HUMANITARIAN AID AND DISASTER RELIEF OPERATIONS MANAGEMENT PLATFORM by Julie A. Reed September
Human-Rated Space Vehicle Backup Flight Systems
NASA Technical Reports Server (NTRS)
Davis, Jeffrey A.; Busa, Joseph L.
2004-01-01
Human rated space vehicles have historically employed a Backup Flight System (BFS) for the main purpose of mitigating the loss of the primary avionics control system. Throughout these projects, however, the underlying philosophy and technical implementation vary greatly. This paper attempts to coalesce each of the past space vehicle program's BFS design and implementation methodologies with the accompanying underlining philosophical arguments that drove each program to such decisions. The focus will be aimed at Mercury, Gemini, Apollo, and Space Shuttle However, the ideologies and implementation of several commercial and military aircraft are incorporated as well to complete the full breadth view of BFS development across the varying industries. In particular to the non-space based vehicles is the notion of deciding not to utilize a BFS. A diverse analysis of BFS to primary system benefits in terms of reliability against all aspects of project development are reviewed and traded. The risk of engaging the BFS during critical stages of flight (e.g. ascent and entry), the level of capability of the BFS (subset capability of main system vs. equivalent system), and the notion of dissimilar hardware and software design are all discussed. Finally, considerations for employing a BFS on future human-rated space missions are reviewed in light of modern avionics architectures and mission scenarios implicit in exploration beyond low Earth orbit.
DOT National Transportation Integrated Search
1995-12-01
Partial failures of aircraft primary flight-control systems and structural : damages to aircraft during flight have led to catastrophic accidents with : subsequent loss of life. These accidents can be prevented if sufficient : alternate control autho...
47 CFR 27.1180 - The cost-sharing formula.
Code of Federal Regulations, 2010 CFR
2010-10-01
...); towers and/or modifications; back-up power equipment; monitoring or control equipment; engineering costs (design/path survey); installation; systems testing; FCC filing costs; site acquisition and civil works... as equipment and engineering expenses. There is no cap on the actual costs of relocation. (c) An AWS...
Concentrating Solar Power Projects - Solana Generating Station |
(APS). The thermal energy storage system provides up to 6 hours of generating capacity after sunset cooling Fossil Backup Type: Natural gas Thermal Storage Storage Type: 2-tank indirect Storage Capacity: 6 hours Thermal Storage Description: Molten salts
Passive cooling system for top entry liquid metal cooled nuclear reactors
Boardman, Charles E.; Hunsbedt, Anstein; Hui, Marvin M.
1992-01-01
A liquid metal cooled nuclear fission reactor plant having a top entry loop joined satellite assembly with a passive auxiliary safety cooling system for removing residual heat resulting from fuel decay during shutdown, or heat produced during a mishap. This satellite type reactor plant is enhanced by a backup or secondary passive safety cooling system which augments the primary passive auxiliary cooling system when in operation, and replaces the primary cooling system when rendered inoperative.
Reliability Analysis of Large Commercial Vessel Engine Room Automation Systems. Volume 1. Results
1982-11-01
analyzing the engine room automiations systems on two steam vessels and one diesel vessel, conducting a criticality evaluation, pre- paring...of automated engine room systems,° the effect of *. maintenance was also to be considered, as was the human inter- face and backup. Besides being...designed to replace the human element, the systems periorm more efficiently than the human watchstander. But as with any system, there is no such thing as
Du, Yatao; Zhang, Huihui; Lu, Jun; Holmgren, Arne
2012-01-01
Thioredoxin reductase 1 (TrxR1) in cytosol is the only known reductant of oxidized thioredoxin 1 (Trx1) in vivo so far. We and others found that aurothioglucose (ATG), a well known active-site inhibitor of TrxR1, inhibited TrxR1 activity in HeLa cell cytosol but had no effect on the viability of the cells. Using a redox Western blot analysis, no change was observed in redox state of Trx1, which was mainly fully reduced with five sulfhydryl groups. In contrast, auranofin killed cells and oxidized Trx1, also targeting mitochondrial TrxR2 and Trx2. Combining ATG with ebselen gave a strong synergistic effect, leading to Trx1 oxidation, reactive oxygen species accumulation, and cell death. We hypothesized that there should exist a backup system to reduce Trx1 when only TrxR1 activity was lost. Our results showed that physiological concentrations of glutathione, NADPH, and glutathione reductase reduced Trx1 in vitro and that the reaction was strongly stimulated by glutaredoxin1. Simultaneous depletion of TrxR activity by ATG and glutathione by buthionine sulfoximine led to overoxidation of Trx1 and loss of HeLa cell viability. In conclusion, the glutaredoxin system and glutathione have a backup role to keep Trx1 reduced in cells with loss of TrxR1 activity. Monitoring the redox state of Trx1 shows that cell death occurs when Trx1 is oxidized, followed by general protein oxidation catalyzed by the disulfide form of thioredoxin. PMID:22977247
Sealing a Loosely Fitting Valve Assembly
NASA Technical Reports Server (NTRS)
Goff, L.; Tellier, G.
1986-01-01
Double-ring seal avoids expense of remachining or redesigning valve parts. Mating fittings on valve sealed by pair of rings - one O-ring and backup ring. Backup ring fills relatively large gap between parts. Prevents softer O-ring from being pushed into and through gap.
Close up of backup exciter showing induction motor at left ...
Close up of backup exciter showing induction motor at left and direct current generator at right. View to west - Mystic Lake Hydroelectric Facility, Powerhouse, Along West Rosebud Creek, 1 3/4 miles northeast of Mystic Lake Dam, Fishtail, Stillwater County, MT
Janssen, Frank; Awadallah, Mohammed; Alhalabi, Awed; Körber, Barbara; Lang, Reinhard; Scibor, Mateusz; Handschu, René
2018-04-01
While telemedicine is in expanding use in acute stroke care, little is known about its use in general neurology, especially in acute care. We sought to investigate the feasibility and possible effects of a telemedicine device within the neurological back-up service of an acute care hospital. In a 450 bed academic teaching hospital an experienced neurologist (EN) is on call to support the junior doctor at the hospital. Support was possible whether by standard telephone advice (TA) or by audiovisual consultations (AVC). In AVC the expert used a mobile telemedicine device and so he could establish audiovisual contact from his home to the emergency room and examine newly admitted patients. Technical and patient details including timing and diagnosis were recorded. Video and audio quality as well as impact of AVC on diagnosis was rated by the EN. Out of about 1200 cases in off peak times, during the study period, 164 AVC including remote video examination were done (13.6%). Also 48 cases were documented by pure TA. Video quality was rated to a medium of 1.7, audio quality to 2.1. In 36 cases the audiovisual consultation was influenced by technical issues leading to cessation of AVC in 8 cases. Duration of teleconsultation was 17.3 min in AVC compared to 8.7 min for TA. The consultation diagnosis in AVC was confirmed in 74.4% of all cases compared to 57.7% in TA. AVC was rated as a valuable contribution to the diagnostic workup in 74.3% of all cases seen. In about 40% of all cases AVC was not possible due to technical or organizational reasons. Audiovisual consultation seems to be a feasible and useful support in routine neurology back-up service of an acute care hospital. Better mobility of devices and flexibility of service is needed to improve availability and quality of this valuable tool.
Control Room Training for the Hyper-X Project Utilizing Aircraft Simulation
NASA Technical Reports Server (NTRS)
Lux-Baumann, Jesica; Dees, Ray; Fratello, David
2006-01-01
The NASA Dryden Flight Research Center flew two Hyper-X research vehicles and achieved hypersonic speeds over the Pacific Ocean in March and November 2004. To train the flight and mission control room crew, the NASA Dryden simulation capability was utilized to generate telemetry and radar data, which was used in nominal and emergency mission scenarios. During these control room training sessions personnel were able to evaluate and refine data displays, flight cards, mission parameter allowable limits, and emergency procedure checklists. Practice in the mission control room ensured that all primary and backup Hyper-X staff were familiar with the nominal mission and knew how to respond to anomalous conditions quickly and successfully. This report describes the technology in the simulation environment and the Mission Control Center, the need for and benefit of control room training, and the rationale and results of specific scenarios unique to the Hyper-X research missions.
Control Room Training for the Hyper-X Program Utilizing Aircraft Simulation
NASA Technical Reports Server (NTRS)
Lux-Baumann, Jessica R.; Dees, Ray A.; Fratello, David J.
2006-01-01
The NASA Dryden Flight Research Center flew two Hyper-X Research Vehicles and achieved hypersonic speeds over the Pacific Ocean in March and November 2004. To train the flight and mission control room crew, the NASA Dryden simulation capability was utilized to generate telemetry and radar data, which was used in nominal and emergency mission scenarios. During these control room training sessions, personnel were able to evaluate and refine data displays, flight cards, mission parameter allowable limits, and emergency procedure checklists. Practice in the mission control room ensured that all primary and backup Hyper-X staff were familiar with the nominal mission and knew how to respond to anomalous conditions quickly and successfully. This paper describes the technology in the simulation environment and the mission control center, the need for and benefit of control room training, and the rationale and results of specific scenarios unique to the Hyper-X research missions.
Kuno, Toshiki; Fujisawa, Taishi; Yamazaki, Hiroyuki; Motoda, Hiroyuki; Kodaira, Masaki; Numasawa, Yohei
2015-01-01
Percutaneous coronary intervention for anomalous right coronary artery (RCA) originating from the left coronary cusp is challenging because of our current inability to coaxially engage the guiding catheter. We report a case of an 88-year-old woman with non-ST segment elevation myocardial infarction, with an anomalous RCA origin. Using either the Judkins-Left catheter or Amplatz-Left catheter was difficult because of RCA ostium tortuosity. Thus, we used steam to deform the Judkins-Left catheter, but back-up support was insufficient to deliver the stent. We used GuideLiner®, a novel pediatric catheter with rapid exchange/monorail systems, to enhance back-up support. We were able to successfully stent with both the deformed Judkins-Left guiding catheter and GuideLiner® for an anomalous RCA origin.
30 CFR 56.14132 - Horns and backup alarms.
Code of Federal Regulations, 2011 CFR
2011-07-01
....14132 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Machinery and Equipment Safety Devices and Maintenance Requirements § 56.14132 Horns and backup alarms. (a) Manually...
30 CFR 56.14132 - Horns and backup alarms.
Code of Federal Regulations, 2010 CFR
2010-07-01
....14132 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Machinery and Equipment Safety Devices and Maintenance Requirements § 56.14132 Horns and backup alarms. (a) Manually...
An audible automobile back-up pedestrian warning device--development and evaluation
DOT National Transportation Integrated Search
1976-11-01
The purpose of the study was to develop and field-test an audible back-up warning device for use on automobiles. Detailed criteria of pedestrian age and hearing ability combined with noise characteristics of typical accident sites provide the basis f...
2016-06-30
At the Cosmonaut Hotel in Baikonur, Kazakhstan, Expedition 48-49 backup crewmember Peggy Whitson of NASA waters a tree in her name first planted in 2007 during traditional pre-launch activities June 30. Whitson is one of three backups to the prime crewmembers, Kate Rubins of NASA, Anatoly Ivanishin of Roscosmos and Takuya Onishi of the Japan Aerospace Exploration Agency, who will launch July 7, Baikonur time, on the Soyuz MS-01 spacecraft for a planned four-month mission on the International Space Station. NASA/Alexander Vysotsky
NASA Technical Reports Server (NTRS)
Flowers, George T.
1994-01-01
Progress over the past year includes the following: A simplified rotor model with a flexible shaft and backup bearings has been developed. A simple rotor model which includes a flexible disk and bearings with clearance has been developed and the dynamics of the model investigated. A rotor model based upon the T-501 engine has been developed which includes backup bearing effects. Parallel simulation runs are being conducted using an ANSYS based finite element model of the T-501. The magnetic bearing test rig is currently floating and dynamics/control tests are being conducted. A paper has been written that documents the work using the T-501 engine model. Work has continued with the simplified model. The finite element model is currently being modified to include the effects of foundation dynamics. A literature search for material on foil bearings has been conducted. A finite element model is being developed for a magnetic bearing in series with a foil backup bearing.
DOT National Transportation Integrated Search
2011-12-01
The purpose of this report is to provide a summary and back-up information on the methodology, data sources, and results for the estimate of Intelligent Transportation Systems (ITS) capital expenditures in the top 75 metropolitan areas as of FY 2010....
78 FR 73144 - Acceleration of Broadband Deployment by Improving Wireless Facilities Siting Policies
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-05
..., ground-based enclosures, battery back-up power systems, grounding equipment, power transfer switch, and... No. 11-59; FCC 13-122] Acceleration of Broadband Deployment by Improving Wireless Facilities Siting... of new wireless facilities and on rules to implement statutory provisions governing State and local...
ERIC Educational Resources Information Center
Waters, John K.
2007-01-01
Information technology (IT) departments are ruled by a kind of Maslow's Hierarchy of Needs: The big-tech stuff--the operating systems, the networks, the data centers--gets the priority, food-and-shelter attention, while upgrading the backup power supplies, evaluating new projector mounts, and taming that rat's nest of classroom cords fall…
BackUp: Development and evaluation of a smart-phone application for coping with suicidal crises
Aerts, Saskia; Muijzers, Ekke; De Jaegere, Eva; van Heeringen, Kees; Portzky, Gwendolyn
2017-01-01
Background Suicide is a major public health issue and has large impact on the lives of many people. Innovative technologies such as smartphones could create new possibilities for suicide prevention, such as helping to overcome the barriers and stigma on help seeking in case of suicidal ideation. Due to their omnipresence, smartphone apps can offer suicide prevention tools very fast, they are easily-accessible, low-threshold and can help overcome some of the help-seeking barriers suicidal people experience. This article describes the development, testing and implementation of a mobile application for coping with suicidal crisis: BackUp. Methods Based on the analysis of literature and existing suicide prevention apps several tools were identified as relevant to include in a suicide prevention app. The selected tools (a safety planning tool, a hope box, a coping cards module, and a module to reach out) are evidence based in a face to face context, and could be easily transferred into a mobile app. The testing of existing apps and the literature also revealed important guidelines for the technical development of the application. Results BackUp was developed and tested by an expert panel (n = 9) and a panel of end users (n = 21). Both groups rated BackUp as valuable for suicide prevention. Suicidal ideation of the end user group was measured using the Beck Scale for Suicidal Ideation before and after testing BackUp, and showed a small but non-significant decrease. The majority of the testers used BackUp several times. All tools were evaluated as rather or very useable in times of suicidal crisis. Conclusion BackUp was positively evaluated and indicates that self-help tools can have a positive impact on suicidal ideation. Apps in particular create opportunities in approaching people that are not reached by traditional interventions; on the other hand they can contribute to suicide prevention in addition to regular care. However, more research is needed on the impact and effect of suicide prevention apps. PMID:28636617
Photovoltaic-Thermal New Technology Demonstration
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dean, Jesse; McNutt, Peter; Lisell, Lars
Photovoltaic-thermal (PV-T) hybrid solar systems offer increased electricity production by cooling the PV panel, and using the removed thermal energy to heat water - all in the same footprint as a standard PV system. GPG's assessment of the nation's first large-scale PV-T system installed at the Thomas P. O'Neill, Jr. Federal Building in Boston, MA, provided numerous lessons learned in system design, and identified a target market of locations with high utility costs and electric hot water backup.
2015-09-01
Training System ARB Aircraft Recovery Bulletins AR Augmented Reality CAG Carrier Air Group CATCC Carrier Air Traffic Control Center COTS...in integration of an optical lens systems into the aircraft carrier. The current generation of optical lens systems integrated into aircraft ...The use of MOVLAS on an aircraft carrier represents a direct communication link between the LSO and pilot. As a backup landing aid system to
Evolution of systems concepts for a 100 kWe class Space Nuclear Power System
NASA Technical Reports Server (NTRS)
Katucki, R.; Josloff, A.; Kirpich, A.; Florio, F.
1985-01-01
Conceptual designs for the SP-100 Space Nuclear Power System have been prepared that meet baseline, backup and growth program scenarios. Near-term advancement in technology was considered in the design of the Baseline Concept. An improved silicon-germanium thermoelectric technique is used to convert the heat from a fast-spectrum, liquid lithium cooled reactor. This system produces a net power of 100 kWe with a 10-year end of life, under the specific constraints of area and volume. Output of the Backup Concept is estimated to be 60 kWe for a 10-year end of life. This system differs from the Baseline Concept because currently available thermoelectric conversion is used from energy supplied by a liquid sodium cooled reactor. The Growth Concept uses Stirling engine conversion to produce 100 kWe within the constraints of mass and volume. The Growth Concept can be scaled up to produce a 1 MWe output that uses the same type reactor developed for the Baseline Concept. Assessments made for each of the program scenarios indicate the key development efforts needed to initiate detailed design and hardware program phases. Development plans were prepared for each scenario that detail the work elements and show the program activities leading to a state of flight readiness.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ma, Zhiwen; Eichman, Josh; Kurtz, Jennifer
This National Renewable Energy Laboratory industry-inspired Laboratory Directed Research and Development project evaluates the feasibility and economics of using fuel cell backup power systems in cell towers to provide grid services (e.g., balancing, ancillary services, demand response). The work is intended to evaluate the integration of thousands of under-utilized, clean, efficient, and reliable fuel cell systems that are already installed in cell towers for potential grid and ancillary services.
NASA Technical Reports Server (NTRS)
Dominguez, Jesus A.; Victor, Elias; Vasquez, Angel L.; Urbina, Alfredo R.
2017-01-01
A multi-threaded software application has been developed in-house by the Ground Special Power (GSP) team at NASA Kennedy Space Center (KSC) to separately simulate and fully emulate all units that supply VDC power and battery-based power backup to multiple KSC launch ground support systems for NASA Space Launch Systems (SLS) rocket.
Space Shuttle Damper System for Ground Wind Load Tests
NASA Technical Reports Server (NTRS)
Robinson, G. D.; Holt, J. R.; Chang, C. S.
1973-01-01
An active damper system which was originally developed for a 5.5% Saturn IB/Skylab Ground Winds Model was modified and used for similar purposes in a Space Shuttle model. A second damper system which was originally used in a 3% Saturn V/Dry Workshop model was also modified and made compatible with the Space Shuttle model to serve as a back-up system. Included in this final report are descriptions of the modified damper systems and the associated control and instrumentation.
Expedition 32 Press Conference
2012-07-13
Quarantined Expedition 32 Canadian backup crewmember Chris Hadfield, right, answers reporters questions from behind glass during a prelaunch press conference held at the Cosmonaut Hotel on Friday, July 13, 2012 in Baikonur, Kazakhstan. Seated next to him is Expedition 32 Russian backup crewmember Roman Romanenko. Photo Credit (NASA/Carla Cioffi)
1965-07-16
S65-28459 (16 July 1965) --- Astronaut Neil A. Armstrong, command pilot for the Gemini-5 backup crew, inside the Gemini Static Article 5 spacecraft prior to water egress training in the Gulf of Mexico. The training is part of the prelaunch schedule for prime and backup crew on the Gemini-5 mission.
2015-02-19
JSC2015E053686 (04/30/2015) --- Expedition 44 backup crew ESA (European Space Agency) astronaut Timothy Peake (left), Russian cosmonaut Yuri Malenchenko (ROSCOSMOS) (center), and NASA astronaut Timothy L. Kopra .
Ceramic backup ring prevents undesirable weld-metal buildup
NASA Technical Reports Server (NTRS)
Leonard, G. E.
1971-01-01
Removable ceramic backup material butted against weld zone back prevents weld metal buildup at that site. Method is successful with manual tungsten-inert gas /TIG/ welding of 316 corrosion resistant steel /CRES/ pieces with 0.76 cm throat diameter and 1.57 cm pipe internal diameter.
System Administrator for LCS Development Sets
NASA Technical Reports Server (NTRS)
Garcia, Aaron
2013-01-01
The Spaceport Command and Control System Project is creating a Checkout and Control System that will eventually launch the next generation of vehicles from Kennedy Space Center. KSC has a large set of Development and Operational equipment already deployed in several facilities, including the Launch Control Center, which requires support. The position of System Administrator will complete tasks across multiple platforms (Linux/Windows), many of them virtual. The Hardware Branch of the Control and Data Systems Division at the Kennedy Space Center uses system administrators for a variety of tasks. The position of system administrator comes with many responsibilities which include maintaining computer systems, repair or set up hardware, install software, create backups and recover drive images are a sample of jobs which one must complete. Other duties may include working with clients in person or over the phone and resolving their computer system needs. Training is a major part of learning how an organization functions and operates. Taking that into consideration, NASA is no exception. Training on how to better protect the NASA computer infrastructure will be a topic to learn, followed by NASA work polices. Attending meetings and discussing progress will be expected. A system administrator will have an account with root access. Root access gives a user full access to a computer system and or network. System admins can remove critical system files and recover files using a tape backup. Problem solving will be an important skill to develop in order to complete the many tasks.
PACS and teleradiology for on-call support of abdominal imaging
NASA Astrophysics Data System (ADS)
Horii, Steven C.; Garra, Brian S.; Mun, Seong K.; Zeman, Robert K.; Levine, Betty A.; Fielding, Robert
1991-07-01
One aspect of the Georgetown image management and communications system (IMACS or PACS) is a built-in capability to support teleradiology. Unlike many dedicated teleradiology systems, the support of this capability as a part of PACS means that any acquired images are remotely accessible, not just those specifically input for transmission. Over the past one and one-half years, two radiologists (SCH, BSG) in the abdominal imaging division of the department of radiology have been accumulating experience with teleradiology for on-call support of emergency abdominal imaging, chiefly in ultrasound. As of the time of this writing, use of the system during on-call (one of these attending radiologists primarily responsible) or back-up call (the attending responsible for the Fellow on primary call) has resulted in a marked reduction in the number of times one of them has to drive to the hospital at night or over the weekend. Approximately 80% of the time, use of the teleradiology system obviates having to go in to review a case. The remainder of the time, the radiologist has to perform a procedure (e.g., abscess drainage) or a scan (e.g., complex Doppler study) himself. This paper reviews the system used for teleradiology, how it is electronically and operationally integrated with the PACS, the clinical benefits and disadvantages of this use, and radiologist and referring physician acceptance.
STS-9 payload specialist Merbold and backup Ockels in training session
NASA Technical Reports Server (NTRS)
1983-01-01
STS-9 payload specialist Ulf Merbold, right, a West German physicist and backup Wubbo Ockels, a Dutch scientist, are pictured in a training session in JSC's Shuttle mockup and integration laboratory. In this view Ockels appears to be showing Merbold how to operate a camera.
30 CFR 57.14132 - Horns and backup alarms for surface equipment.
Code of Federal Regulations, 2010 CFR
2010-07-01
... NONMETAL MINES Machinery and Equipment Safety Devices and Maintenance Requirements § 57.14132 Horns and backup alarms for surface equipment. (a) Manually-operated horns or other audible warning devices provided on self-propelled mobile equipment as a safety device shall be maintained in a functional...
26 CFR 31.3406-0 - Outline of the backup withholding regulations.
Code of Federal Regulations, 2013 CFR
2013-04-01
... incorrect name/TIN combination. (2) Definition of account. (3) Definition of business day. (4) Certain exceptions. (c) Notice regarding an incorrect name/TIN combination. (1) In general. (2) Additional... of receipt. (d) Notice from payors of backup withholding due to an incorrect name/TIN combination. (1...
75 FR 61655 - Airworthiness Directives; Piper Aircraft, Inc. Model PA-28-161 Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2010-10-06
... (FADEC) backup battery, replacing the supplement pilot's operating handbook and FAA approved airplane... can allow the FADEC to shut down or reset if the main battery is depleted and the electrical charging... service information describes procedures for installation of a FADEC backup battery. FAA's Determination...
Expedition 14 Crew and Backup Crew Training
2006-05-24
JSC2006-E-20053 (24 May 2006) --- Astronaut Clayton C. Anderson, Expedition 14 backup flight engineer, participates in Journals experiment overview training in the Flight Operations Facility at Johnson Space Center. This type of training is a presentation format regarding the experiment objectives and tools. Training instructor Lindsay Kirschner assisted Anderson.
Emergency Care Capabilities in North East Haiti: A Cross-sectional Observational Study.
De Wulf, Annelies; Aluisio, Adam R; Muhlfelder, Dana; Bloem, Christina
2015-12-01
The North East Department is a resource-limited region of Haiti. Health care is provided by hospitals and community clinics, with no formal Emergency Medical System and undefined emergency services. As a paucity of information exists on available emergency services in the North East Department of Haiti, the objective of this study was to assess systematically the existing emergency care resources in the region. This cross-sectional observational study was carried out at all Ministry of Public Health and Population (MSPP)-affiliated hospitals in the North East Department and all clinics within the Fort Liberté district. A modified version of the World Health Organization (WHO) Tool for Situational Analysis to Assess Emergency and Essential Surgical Care and Generic Essential Emergency Equipment Lists were completed for each facility. Three MSPP hospitals and five clinics were assessed. Among hospitals, all had a designated emergency ward with 24 hour staffing by a medical doctor. All hospitals had electricity with backup generators and access to running water; however, none had potable water. All hospitals had x-ray and ultrasound capabilities. No computed tomography scanners existed in the region. Invasive airway equipment and associated medications were not present consistently in the hospitals' emergency care areas, but they were available in the operating rooms. Pulse oximetry was unavailable uniformly. One hospital had intermittently functioning defibrillation equipment, and two hospitals had epinephrine. Basic supplies for managing obstetrical and traumatic emergencies were available at all hospitals. Surgical services were accessible at two hospitals. No critical care services were available in the region. Clinics varied widely in terms of equipment availability. They uniformly had limited emergency medical equipment. The clinics also had inconsistent access to basic assessment tools (sphygmomanometers 20% and stethoscopes 60%). A protocol for transferring patients requiring a higher level of care was present in most (80%) clinics and one of the hospitals. However, no facility had a written protocol for transferring patients to other facilities. One hospital reported intermittent access to an ambulance for transfers. Deficits in the supply of emergency equipment and limited protocols for inter-facility transfers exist in North East Department of Haiti. These essential areas represent appropriate targets for interventions aimed at improving access to emergency care within the North East region of Haiti.
NASA Technical Reports Server (NTRS)
Gerren, Donna S.
1995-01-01
A study has been conducted to determine the capability to control a very large transport airplane with engine thrust. This study consisted of the design of an 800-passenger airplane with a range of 5000 nautical miles design and evaluation of a flight control system, and design and piloted simulation evaluation of a thrust-only backup flight control system. Location of the four wing-mounted engines was varied to optimize the propulsive control capability, and the time constant of the engine response was studied. The goal was to provide level 1 flying qualities. The engine location and engine time constant did not have a large effect on the control capability. The airplane design did meet level 1 flying qualities based on frequencies, damping ratios, and time constants in the longitudinal and lateral-directional modes. Project pilots consistently rated the flying qualities as either level 1 or level 2 based on Cooper-Harper ratings. However, because of the limited control forces and moments, the airplane design fell short of meeting the time required to achieve a 30 deg bank and the time required to respond a control input.
Restoring Redundancy to the Wilkinson Microwave Anisotrophy Probe Propulsion System
NASA Technical Reports Server (NTRS)
O'Donnell, James R., Jr.; Davis, Gary T.; Ward, David K.
2004-01-01
The Wilkinson Microwave Anisotropy Probe is a follow-on to the Differential Microwave Radiometer instrument on the Cosmic Background Explorer. Attitude control system engineers discovered sixteen months before launch that configuration changes after the critical design review had resulted in a significant migration of the spacecraft's center of mass. As a result, the spacecraft no longer had a viable backup control mode in the event of a failure of the negative pitch-axis thruster. A tiger team was formed and identified potential solutions to this problem, such as adding thruster-plume shields to redirect thruster torque, adding or removing mass from the spacecraft, adding an additional thruster, moving thrusters, bending thruster nozzles or propellant tubing, or accepting the loss of redundancy. The project considered the impacts on mass, cost, fuel budget, and schedule for each solution, and decided to bend the propellant tubing of the two roll-control thrusters to allow the pair to be used for backup control in the negative pitch axis. This paper discusses the problem and the potential solutions, and documents the hardware and software changes and verification performed. Flight data are presented to show the on-orbit performance of the propulsion system and lessons learned are described.
Novel elastic protection against DDF failures in an enhanced software-defined SIEPON
NASA Astrophysics Data System (ADS)
Pakpahan, Andrew Fernando; Hwang, I.-Shyan; Yu, Yu-Ming; Hsu, Wu-Hsiao; Liem, Andrew Tanny; Nikoukar, AliAkbar
2017-07-01
Ever-increasing bandwidth demands on passive optical networks (PONs) are pushing the utilization of every fiber strand to its limit. This is mandating comprehensive protection until the end of the distribution drop fiber (DDF). Hence, it is important to provide refined protection with an advanced fault-protection architecture and recovery mechanism that is able to cope with various DDF failures. We propose a novel elastic protection against DDF failures that incorporates a software-defined networking (SDN) capability and a bus protection line to enhance the resiliency of the existing Service Interoperability in Ethernet Passive Optical Networks (SIEPON) system. We propose the addition of an integrated SDN controller and flow tables to the optical line terminal and optical network units (ONUs) in order to deliver various DDF protection scenarios. The proposed architecture enables flexible assignment of backup ONU(s) in pre/post-fault conditions depending on the PON traffic load. A transient backup ONU and multiple backup ONUs can be deployed in the pre-fault and post-fault scenarios, respectively. Our extensively discussed simulation results show that our proposed architecture provides better overall throughput and drop probability compared to the architecture with a fixed DDF protection mechanism. It does so while still maintaining overall QoS performance in terms of packet delay, mean jitter, packet loss, and throughput under various fault conditions.
Final Environmental Impact Statement for the Galileo Mission (Tier 2)
NASA Technical Reports Server (NTRS)
1989-01-01
This Final Environmental Impact Statement (FEIS) addresses the proposed action of completing the preparation and operation of the Galileo spacecraft, including its planned launch on the Space Transportation System (STS) Shuttle in October 1989, and the alternative of canceling further work on the mission. The Tier 1 (program level) EIS (NASA 1988a) considered the Titan IV launch vehicle as an alternative booster stage for launch in May 1991 or later. The May 1991 Venus launch opportunity is considered a planetary back-up for the Magellan (Venus Radar Mapper) mission, the Galileo mission, and the Ulysses mission. Plans were underway to enable the use of a Titan IV launch vehicle for the planetary back-up. However, in November 1988, the U.S. Air Force, which procures the Titan IV for NASA, notified NASA that it could not provide a Titan IV vehicle for the May 1991 launch opportunity due to high priority Department of Defense requirements. Consequently, NASA terminated all mission planning for the Titan IV planetary back-up. A minimum of 3 years is required to implement mission-specific modifications to the basic Titan IV launch configuration; therefore, insufficient time is available to use a Titan IV vehicle in May 1991. Thus, the Titan IV launch vehicle is no longer a feasible alternative to the STS/Inertial Upper Stage (IUS) for the May 1991 launch opportunity.
A Fault Tolerance Mechanism for On-Road Sensor Networks
Feng, Lei; Guo, Shaoyong; Sun, Jialu; Yu, Peng; Li, Wenjing
2016-01-01
On-Road Sensor Networks (ORSNs) play an important role in capturing traffic flow data for predicting short-term traffic patterns, driving assistance and self-driving vehicles. However, this kind of network is prone to large-scale communication failure if a few sensors physically fail. In this paper, to ensure that the network works normally, an effective fault-tolerance mechanism for ORSNs which mainly consists of backup on-road sensor deployment, redundant cluster head deployment and an adaptive failure detection and recovery method is proposed. Firstly, based on the N − x principle and the sensors’ failure rate, this paper formulates the backup sensor deployment problem in the form of a two-objective optimization, which explains the trade-off between the cost and fault resumption. In consideration of improving the network resilience further, this paper introduces a redundant cluster head deployment model according to the coverage constraint. Then a common solving method combining integer-continuing and sequential quadratic programming is explored to determine the optimal location of these two deployment problems. Moreover, an Adaptive Detection and Resume (ADR) protocol is deigned to recover the system communication through route and cluster adjustment if there is a backup on-road sensor mismatch. The final experiments show that our proposed mechanism can achieve an average 90% recovery rate and reduce the average number of failed sensors at most by 35.7%. PMID:27918483
Proper battery system design for GAS experiments
NASA Astrophysics Data System (ADS)
Calogero, Stephen A.
1992-10-01
The purpose of this paper is to help the GAS experimenter to design a battery system that meets mission success requirements while at the same time reducing the hazards associated with the battery system. Lead-acid, silver-zinc and alkaline chemistry batteries will be discussed. Lithium batteries will be briefly discussed with emphasis on back-up power supply capabilities. The hazards associated with different battery configurations will be discussed along with the controls necessary to make the battery system two-fault tolerant.
Proper battery system design for GAS experiments
NASA Technical Reports Server (NTRS)
Calogero, Stephen A.
1992-01-01
The purpose of this paper is to help the GAS experimenter to design a battery system that meets mission success requirements while at the same time reducing the hazards associated with the battery system. Lead-acid, silver-zinc and alkaline chemistry batteries will be discussed. Lithium batteries will be briefly discussed with emphasis on back-up power supply capabilities. The hazards associated with different battery configurations will be discussed along with the controls necessary to make the battery system two-fault tolerant.
1982-10-01
this is critical. All buoy and many shore based systems employ back-up systems . In the case of buoys, 4 -when a lamp fails to emit, a new lamp is...88 LIST OF TABLES 1. Incandescent Source Table of Information -------------------- 38 2. Background Information on Subjects...functional aids-to-navigation system . The principal component of this system is the lighted aid which exists in many forms, from the wind and wave
Kuno, Toshiki; Fujisawa, Taishi; Yamazaki, Hiroyuki; Motoda, Hiroyuki; Kodaira, Masaki; Numasawa, Yohei
2015-01-01
Objective: Percutaneous coronary intervention for anomalous right coronary artery (RCA) originating from the left coronary cusp is challenging because of our current inability to coaxially engage the guiding catheter. Methods: We report a case of an 88-year-old woman with non-ST segment elevation myocardial infarction, with an anomalous RCA origin. Using either the Judkins-Left catheter or Amplatz-Left catheter was difficult because of RCA ostium tortuosity. Thus, we used steam to deform the Judkins-Left catheter, but back-up support was insufficient to deliver the stent. Results: We used GuideLiner®, a novel pediatric catheter with rapid exchange/monorail systems, to enhance back-up support. Conclusions: We were able to successfully stent with both the deformed Judkins-Left guiding catheter and GuideLiner® for an anomalous RCA origin. PMID:27489700
DOE Office of Scientific and Technical Information (OSTI.GOV)
Beenstock, M.; Goldin, E.; Haitovsky, Y.
1997-05-01
The economic cost of power outages is a central parameter in the cost-benefit analysis of electric power reliability and the design of electric power systems. The authors present a new methodology for estimating the cost of power outages in the business and public sections and illustrate with data for Israel. The methodology is based on the principle of revealed preference, the cost of an outage may be inferred from the actions taken by consumers to mitigate losses induced by unsupplied electricity. If outages impose costs on businesses, managers are likely to invest in back-up power to mitigate the losses thatmore » are incurred when electricity is not supplied. Investment in back-up generators may then be used to impute the mitigated and unmitigated damage from outages. 12 refs., 3 figs., 7 tabs.« less
77 FR 2048 - Privacy Act of 1974 System of Records Notice
Federal Register 2010, 2011, 2012, 2013, 2014
2012-01-13
..., including the CFTC Intranet and social media tools within the Intranet. DATES: Comments must be received on... limited social networking through the SharePoint ``MySites'' feature. The new Intranet, built on these... electronic media as needed, such as encrypted hard drives and back-up media. RETRIEVABILITY: By name of the...
2009 Joint Service Power Expo volume 2 video
2009-05-07
8483 - “A Field-Portable Lithium Ion Battery Charger with UPS Back-up Capability”, Mr. Neil Steven Graves, Acumentrics · 8394 - “Kestrel...Control”, Mr. Rick Silva, Sr. System Engineer, Custom Manufacturing & Engineering, Inc · 8371 - “New Application of Lithium - Ion Battery in Hybrid Power Supply System”, Mr. Takefumi Inoue, GS Yuasa Corporation
ERIC Educational Resources Information Center
Zambon, Franco
This study sought to determine a useful frequency for refreshing students' memories of complex procedures that involved a formal computer language. Students were required to execute the Microsoft Disc Operating System (MS-DOS) commands for "copy,""backup," and "restore." A total of 126 college students enrolled in six…
Database Systems and Oracle: Experiences and Lessons Learned
ERIC Educational Resources Information Center
Dunn, Deborah
2005-01-01
In a tight job market, IT professionals with database experience are likely to be in great demand. Companies need database personnel who can help improve access to and security of data. The events of September 11 have increased business' awareness of the need for database security, backup, and recovery procedures. It is our responsibility to…
2013-09-06
At the Kremlin Wall at Red Square in Moscow, Five of the six Expedition 37/38 prime and backup crewmembers pose for pictures Sept. 6 during the traditional visit to lay flowers at the wall where Russian space icons are interred. With the onion domed spires of St. Basil’s Cathedral in the background, from left to right are backup NASA Flight Engineer Steve Swanson, prime Flight Engineer Michael Hopkins of NASA, prime Soyuz Commander Oleg Kotov, prime Flight Engineer Sergey Ryazanskiy and backup Flight Engineer Oleg Artemyev. Hopkins, Kotov and Ryazanskiy are preparing for their launch to the International Space Station from the Baikonur Cosmodrome in Kazakhstan on Sept. 26, Kazakh time, aboard the Soyuz TMA-10M spacecraft. NASA/Stephanie Stoll
A practical approach for inexpensive searches of radiology report databases.
Desjardins, Benoit; Hamilton, R Curtis
2007-06-01
We present a method to perform full text searches of radiology reports for the large number of departments that do not have this ability as part of their radiology or hospital information system. A tool written in Microsoft Access (front-end) has been designed to search a server (back-end) containing the indexed backup weekly copy of the full relational database extracted from a radiology information system (RIS). This front end-/back-end approach has been implemented in a large academic radiology department, and is used for teaching, research and administrative purposes. The weekly second backup of the 80 GB, 4 million record RIS database takes 2 hours. Further indexing of the exported radiology reports takes 6 hours. Individual searches of the indexed database typically take less than 1 minute on the indexed database and 30-60 minutes on the nonindexed database. Guidelines to properly address privacy and institutional review board issues are closely followed by all users. This method has potential to improve teaching, research, and administrative programs within radiology departments that cannot afford more expensive technology.
Towards a Net Zero Building Cluster Energy Systems Analysis for a Brigade Combat Team Complex
2010-05-01
of technologies, like cogeneration or combined heat and power, waste heat recovery, biomass, geother- mal energy, solar heating (and cooling), and...peaks of individual buildings; thus the needed gen- eration and back-up capacity is smaller. To develop the community energy concept, energy models...overall thermal energy system, a hydraulic flow model (Figure 5) should be used to analyze critical capacities and flows in the system. This material is
Coordinated train control and energy management control strategies
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gordon, S.P.; Lehrer, D.G.
1998-05-01
The Bay Area Rapid Transit (BART) system, in collaboration with Hughes Aircraft Company and Harmon Industries, as in the process of developing an Advanced Automatic Train Control (AATC) system to replace the current fixed-block automatic system. In the long run, the AATC system is expected to not only allow for safe short headway operation, but also to facilitate coordinated train control and energy management. This new system will employ spread spectrum radios, installed onboard trains, at wayside locations, and at control stations, to determine train locations and reliably transfer control information. Sandia National Laboratories has worked cooperatively with BART tomore » develop a simulator of the train control and the power consumption of the AATC system. The authors are now in the process of developing enhanced train control algorithms to supplement the safety critical controller in order to smooth out train trajectories through coordinated control of multiple trains, and to reduce energy consumption and power infrastructure requirements. The control algorithms so far considered include (1) reducing peak power consumption to avoid voltage sags, especially during an outage or while clearing a backup, (2) rapid and smooth recovery from a backup, (3) avoiding oscillations due to train interference, (4) limiting needle peaks in power demand at substations to some specified level, (5) coasting, and (6) coordinating train movement, e.g., starts/stops and hills.« less
USDA-ARS?s Scientific Manuscript database
Both the United States and Brazil maintain vast collections of grape genetic resources. We share a common interest in using cryopreservation methods for the secure, long-term back-up of accessions within these field collections of the USDA-ARS National Plant Germplasm System and UDESC-CAV Santa Cata...
Environmental Assessment: Building 3001 Tinker Air Force Base, Oklahoma
2008-09-01
developing a Memorandum of Agreement (MOA) with the SHPO and the Oklahoma Archaeological Survey regarding the potential effects the Proposed Action...3.3.5.4 Electrical System Tinker AFB receives its electrical power from Oklahoma Gas and Electric, which delivers power through a looped 138... gas , with diesel fuel used as the backup supply. The steam line system is primarily underground, with a limited number of lines extending
CH-47C Vulnerability Reduction Modification Program - Fly-by-Wire Backup Demonstration
1976-08-01
Actuator Position for Combined Axis Input ............................. 91 4 Systems Assessment Summary................... 95 C-1 Instrumentation Parameters ...SERVO CARD jEETO FROM MIXERS SUfEV __________ HYLIC AMPL AMPLVLE SHUT-O- DOWN DC PWR LOGIC REA MIONITOR SUMMER *O:EO SWITCH- BUFFER OVER 1 NETWORK...and ranels (Figures 12 and 13). The existing DELS preflight test set, which provides access to the system parameters , was installed along with the
Assessing the techno-economics of modular hybrid solar thermal systems
NASA Astrophysics Data System (ADS)
Lim, Jin Han; Chinnici, Alfonso; Dally, Bassam; Nathan, Graham
2017-06-01
A techno-economic assessment was performed on modular hybrid solar thermal (in particular, solar power tower) systems with combustion from natural gas as backup to provide a continuous supply of electricity. Two different configurations were compared, i.e. a Hybrid Solar Receiver Combustor (HSRC), in which the functions of a solar cavity receiver and a combustor are integrated into a single device, and a Solar Gas Hybrid (SGH), which is a reference hybrid solar thermal system with a standalone solar-only cavity receiver and a backup boiler. The techno-economic benefits were assessed by varying the size of the modular components, i.e. the heliostat field and the solar receivers. It was found that for modularization to be cost effective requires more than the increased learning from higher production of a larger number of smaller units, such as access to alternative, lower-cost manufacturing methods and/or the use of a low melting point Heat Transfer Fluid (HTF) such as sodium to reduce parasitic losses. In particular, for a plant with 30 units of 1MWth modules, the Levelized Cost of Electricity is competitive compared with a single unit of 30MWth after ˜100 plants are installed for both the HSRC and SGH if the systems employ the use of sodium as the heat transfer fluid.
Final Report: Assessment of Combined Heat and Power Premium Power Applications in California
DOE Office of Scientific and Technical Information (OSTI.GOV)
Norwood, Zack; Lipman, Tim; Marnay, Chris
2008-09-30
This report analyzes the current economic and environmental performance of combined heat and power (CHP) systems in power interruption intolerant commercial facilities. Through a series of three case studies, key trade-offs are analyzed with regard to the provision of black-out ridethrough capability with the CHP systems and the resutling ability to avoid the need for at least some diesel backup generator capacity located at the case study sites. Each of the selected sites currently have a CHP or combined heating, cooling, and power (CCHP) system in addition to diesel backup generators. In all cases the CHP/CCHP system have a smallmore » fraction of the electrical capacity of the diesel generators. Although none of the selected sites currently have the ability to run the CHP systems as emergency backup power, all could be retrofitted to provide this blackout ride-through capability, and new CHP systems can be installed with this capability. The following three sites/systems were used for this analysis: (1) Sierra Nevada Brewery - Using 1MW of installed Molten Carbonate Fuel Cells operating on a combination of digestor gas (from the beer brewing process) and natural gas, this facility can produce electricty and heat for the brewery and attached bottling plant. The major thermal load on-site is to keep the brewing tanks at appropriate temperatures. (2) NetApp Data Center - Using 1.125 MW of Hess Microgen natural gas fired reciprocating engine-generators, with exhaust gas and jacket water heat recovery attached to over 300 tons of of adsorption chillers, this combined cooling and power system provides electricity and cooling to a data center with a 1,200 kW peak electrical load. (3) Kaiser Permanente Hayward Hospital - With 180kW of Tecogen natural gas fired reciprocating engine-generators this CHP system generates steam for space heating, and hot water for a city hospital. For all sites, similar assumptions are made about the economic and technological constraints of the power generation system. Using the Distributed Energy Resource Customer Adoption Model (DER-CAM) developed at the Lawrence Berkeley National Laboratory, we model three representative scenarios and find the optimal operation scheduling, yearly energy cost, and energy technology investments for each scenario below: Scenario 1 - Diesel generators and CHP/CCHP equipment as installed in the current facility. Scenario 1 represents a baseline forced investment in currently installed energy equipment. Scenario 2 - Existing CHP equipment installed with blackout ride-through capability to replace approximately the same capacity of diesel generators. In Scenario 2 the cost of the replaced diesel units is saved, however additional capital cost for the controls and switchgear for blackout ride-through capability is necessary. Scenario 3 - Fully optimized site analysis, allowing DER-CAM to specify the number of diesel and CHP/CCHP units (with blackout ride-through capability) that should be installed ignoring any constraints on backup generation. Scenario 3 allows DER-CAM to optimize scheduling and number of generation units from the currently available technologies at a particular site. The results of this analysis, using real data to model the optimal schedulding of hypothetical and actual CHP systems for a brewery, data center, and hospital, lead to some interesting conclusions. First, facilities with high heating loads will typically prove to be the most appropriate for CHP installation from a purely economic standpoint. Second, absorption/adsorption cooling systems may only be economically feasible if the technology for these chillers can increase above current best system efficiency. At a coefficient of performance (COP) of 0.8, for instance, an adsorption chiller paired with a natural gas generator with waste heat recovery at a facility with large cooling loads, like a data center, will cost no less on a yearly basis than purchasing electricity and natural gas directly from a utility. Third, at marginal additional cost, if the reliability of CHP systems proves to be at least as high as diesel generators (which we expect to be the case), the CHP system could replace the diesel generator at little or no additional cost. This is true if the thermal to electric (relative) load of those facilities was already high enough to economically justify a CHP system. Last, in terms of greenhouse gas emissions, the modeled CHP and CCHP systems provide some degree of decreased emissions relative to systems with less CHP installed. The emission reduction can be up to 10% in the optimized case (Scenario 3) in the application with the highest relative thermal load, in this case the hospital. Although these results should be qualified because they are only based on the three case studies, the general results and lessons learned are expected to be applicable across a broad range of potential and existing CCHP systems.« less
38 CFR 17.230 - Contingency backup to the Department of Defense.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 38 Pensions, Bonuses, and Veterans' Relief 1 2010-07-01 2010-07-01 false Contingency backup to the Department of Defense. 17.230 Section 17.230 Pensions, Bonuses, and Veterans' Relief DEPARTMENT OF VETERANS... the Department of Defense. (a) Priority care to active duty personnel. The Secretary, during and/or...
38 CFR 17.230 - Contingency backup to the Department of Defense.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 38 Pensions, Bonuses, and Veterans' Relief 1 2011-07-01 2011-07-01 false Contingency backup to the Department of Defense. 17.230 Section 17.230 Pensions, Bonuses, and Veterans' Relief DEPARTMENT OF VETERANS... the Department of Defense. (a) Priority care to active duty personnel. The Secretary, during and/or...
38 CFR 17.230 - Contingency backup to the Department of Defense.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 38 Pensions, Bonuses, and Veterans' Relief 1 2012-07-01 2012-07-01 false Contingency backup to the Department of Defense. 17.230 Section 17.230 Pensions, Bonuses, and Veterans' Relief DEPARTMENT OF VETERANS... the Department of Defense. (a) Priority care to active duty personnel. The Secretary, during and/or...
38 CFR 17.230 - Contingency backup to the Department of Defense.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 38 Pensions, Bonuses, and Veterans' Relief 1 2014-07-01 2014-07-01 false Contingency backup to the Department of Defense. 17.230 Section 17.230 Pensions, Bonuses, and Veterans' Relief DEPARTMENT OF VETERANS... the Department of Defense. (a) Priority care to active duty personnel. The Secretary, during and/or...
38 CFR 17.230 - Contingency backup to the Department of Defense.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 38 Pensions, Bonuses, and Veterans' Relief 1 2013-07-01 2013-07-01 false Contingency backup to the Department of Defense. 17.230 Section 17.230 Pensions, Bonuses, and Veterans' Relief DEPARTMENT OF VETERANS... the Department of Defense. (a) Priority care to active duty personnel. The Secretary, during and/or...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-10-23
... Adopted Under Rule 205 Entitled ``Back-Up Communication Channel to Internet Access'' October 17, 2013. I... ``Back-up Communication Channel to Internet Access'' requiring clearing members that use the internet as... Policy Statement under Rule 205 requiring clearing members that primarily use the internet to access OCC...
A total system approach to sustainable pest management
Lewis, W. J.; van Lenteren, J. C.; Phatak, Sharad C.; Tumlinson, J. H.
1997-01-01
A fundamental shift to a total system approach for crop protection is urgently needed to resolve escalating economic and environmental consequences of combating agricultural pests. Pest management strategies have long been dominated by quests for “silver bullet” products to control pest outbreaks. However, managing undesired variables in ecosystems is similar to that for other systems, including the human body and social orders. Experience in these fields substantiates the fact that therapeutic interventions into any system are effective only for short term relief because these externalities are soon “neutralized” by countermoves within the system. Long term resolutions can be achieved only by restructuring and managing these systems in ways that maximize the array of “built-in” preventive strengths, with therapeutic tactics serving strictly as backups to these natural regulators. To date, we have failed to incorporate this basic principle into the mainstream of pest management science and continue to regress into a foot race with nature. In this report, we establish why a total system approach is essential as the guiding premise of pest management and provide arguments as to how earlier attempts for change and current mainstream initiatives generally fail to follow this principle. We then draw on emerging knowledge about multitrophic level interactions and other specific findings about management of ecosystems to propose a pivotal redirection of pest management strategies that would honor this principle and, thus, be sustainable. Finally, we discuss the potential immense benefits of such a central shift in pest management philosophy. PMID:9356432
NASA Astrophysics Data System (ADS)
Liu, Brent J.; Documet, Luis; Documet, Jorge; Huang, H. K.; Muldoon, Jean
2004-04-01
An Application Service Provider (ASP) archive model for disaster recovery for Saint John"s Health Center (SJHC) clinical PACS data has been implemented using a Fault-Tolerant Archive Server at the Image Processing and Informatics Laboratory, Marina del Rey, CA (IPIL) since mid-2002. The purpose of this paper is to provide clinical experiences with the implementation of an ASP model backup archive in conjunction with handheld wireless technologies for a particular disaster recovery scenario, an earthquake, in which the local PACS archive and the hospital are destroyed and the patients are moved from one hospital to another. The three sites involved are: (1) SJHC, the simulated disaster site; (2) IPIL, the ASP backup archive site; and (3) University of California, Los Angeles Medical Center (UCLA), the relocated patient site. An ASP backup archive has been established at IPIL to receive clinical PACS images daily using a T1 line from SJHC for backup and disaster recovery storage. Procedures were established to test the network connectivity and data integrity on a regular basis. In a given disaster scenario where the local PACS archive has been destroyed and the patients need to be moved to a second hospital, a wireless handheld device such as a Personal Digital Assistant (PDA) can be utilized to route images to the second hospital site with a PACS and reviewed by radiologists. To simulate this disaster scenario, a wireless network was implemented within the clinical environment in all three sites: SJHC, IPIL, and UCLA. Upon executing the disaster scenario, the SJHC PACS archive server simulates a downtime disaster event. Using the PDA, the radiologist at UCLA can query the ASP backup archive server at IPIL for PACS images and route them directly to UCLA. Implementation experiences integrating this solution within the three clinical environments as well as the wireless performance are discussed. A clinical downtime disaster scenario was implemented and successfully tested. Radiologists were able to successfully query PACS images utilizing a wireless handheld device from the ASP backup archive at IPIL and route the PACS images directly to a second clinical site at UCLA where they and the patients are located at that time. In a disaster scenario, using a wireless device, radiologists at the disaster health care center can route PACS data from an ASP backup archive server to be reviewed in a live clinical PACS environment at a secondary site. This solution allows Radiologists to use a wireless handheld device to control the image workflow and to review PACS images during a major disaster event where patients must be moved to a secondary site.
PC-403: Pioneer Venus multiprobe spacecraft mission operational characteristics document, volume 3
NASA Technical Reports Server (NTRS)
Barker, F. C.
1978-01-01
The Pioneer Venus spacecraft primary and backup operational modes and operational limitations for maneuvers, roll references transfer, attitude determination, spacecraft power discipline and spacecraft thermal discipline, are described. The functions and operations of the large and small probes, as well detailed performance in the normal operating modes and backup modes are presented.
Recommended high-tank temperatures for maintenance of high-tank backup support, Revision 3
DOE Office of Scientific and Technical Information (OSTI.GOV)
Greager, O.H.
1964-05-20
Purpose of this note is to recommend revised curves for the high-tank temperature required to maintain adequate high-tank backup support at the six small reactors. Compliance with the conditions shown on these curves will ensure adequate high-tank flow rates following the simultaneous loss of electric and steam power.
Towards Efficient Scientific Data Management Using Cloud Storage
NASA Technical Reports Server (NTRS)
He, Qiming
2013-01-01
A software prototype allows users to backup and restore data to/from both public and private cloud storage such as Amazon's S3 and NASA's Nebula. Unlike other off-the-shelf tools, this software ensures user data security in the cloud (through encryption), and minimizes users operating costs by using space- and bandwidth-efficient compression and incremental backup. Parallel data processing utilities have also been developed by using massively scalable cloud computing in conjunction with cloud storage. One of the innovations in this software is using modified open source components to work with a private cloud like NASA Nebula. Another innovation is porting the complex backup to- cloud software to embedded Linux, running on the home networking devices, in order to benefit more users.
CREW TRAINING - STS-33/51L (ZERO-G)
1985-11-20
S85-44835 (20 Nov. 1985) --- This flying human chain represents prime and backup payload specialists for two upcoming STS missions. The group, representing trainees for STS-61C later this year and STS-51L early next year, shared some 40 parabolas in NASA?s KSC-135, ?Zero-G? aircraft on Nov. 20. Left to right are Gerard Magilton, RCA backup payload specialist for STS-61C; Sharon Christa McAuliffe, payload specialist/teacher citizen observer for STS-51L; U.S. Rep. Bill Nelson (D., Florida), scheduled for 61-C; Barbara R. Morgan, backup to McAuliffe; and Robert J. Cenker, RCA payload specialist for 61-C. The photo was taken by Keith Meyers, New York Times. Photo credit: NASA
CREW TRAINING - STS-33/51-L (Zero-G)
1985-11-20
S85-44834 (20 Nov. 1985) --- This flying human chain represents prime and backup payload specialists for two upcoming STS missions. The group, representing trainees for STS-61C later this year and STS-51L early next year, shared some 40 parabolas in NASA?s KC-135, ?Zero-G? aircraft on Nov. 20, 1985. Left to right are Gerard Magilton, RCA backup payload specialist for STS-61C; Sharon Christa McAuliffe, payload specialist/teacher citizen observer for STS-51L; U.S. Representative Bill Nelson (D., Florida), scheduled for 61C; Barbara R. Morgan, backup to McAuliffe; and Robert J. Cenker, RCA payload specialist for 61C. The photo was taken by Otis Imboden. Photo credit: NASA
NASA Technical Reports Server (NTRS)
Moses, John F.; Memarsadeghi, Nargess; Overoye, David; Littlefield, Brain
2017-01-01
The Global Learning and Observation to Benefit the Environment (GLOBE) Data and Information System supports an international science and education program with capabilities to accept local environment observations, archive, display and visualize them along with global satellite observations. Since its inception twenty years ago, the Web and database system has been upgraded periodically to accommodate the changes in technology and the steady growth of GLOBEs education community and collection of observations. Recently, near the end-of-life of the system hardware, new commercial computer platform options were explored and a decision made to utilize Cloud services. Now the GLOBE DIS has been fully deployed and maintained using Amazon Cloud services for over two years now. This paper reviews the early risks, actual challenges, and some unexpected findings as a result of the GLOBE DIS migration. We describe the plans, cost drivers and estimates, highlight adjustments that were made and suggest improvements. We present the trade studies for provisioning, for load balancing, networks, processing, storage, as well as production, staging and backup systems. We outline the migration teams skills and required level of effort for transition, and resulting changes in the overall maintenance and operations activities. Examples include incremental adjustments to processing capacity and frequency of backups, and efforts previously expended on hardware maintenance that were refocused onto application-specific enhancements.
NASA Technical Reports Server (NTRS)
Moses, John F.; Memarsadeghi, Nargess; Overoye, David; Littlefield, Bryan
2016-01-01
The Global Learning and Observation to Benefit the Environment (GLOBE) Data and Information System supports an international science and education program with capabilities to accept local environment observations, archive, display and visualize them along with global satellite observations. Since its inception twenty years ago, the Web and database system has been upgraded periodically to accommodate the changes in technology and the steady growth of GLOBEs education community and collection of observations. Recently, near the end-of-life of the system hardware, new commercial computer platform options were explored and a decision made to utilize Cloud services. Now the GLOBE DIS has been fully deployed and maintained using Amazon Cloud services for over two years now. This paper reviews the early risks, actual challenges, and some unexpected findings as a result of the GLOBE DIS migration. We describe the plans, cost drivers and estimates, highlight adjustments that were made and suggest improvements. We present the trade studies for provisioning, for load balancing, networks, processing, storage, as well as production, staging and backup systems. We outline the migration teams skills and required level of effort for transition, and resulting changes in the overall maintenance and operations activities. Examples include incremental adjustments to processing capacity and frequency of backups, and efforts previously expended on hardware maintenance that were refocused onto application-specific enhancements.
NASA Astrophysics Data System (ADS)
Moses, J. F.; Memarsadeghi, N.; Overoye, D.; Littlefield, B.
2016-12-01
The Global Learning and Observation to Benefit the Environment (GLOBE) Data and Information System supports an international science and education program with capabilities to accept local environment observations, archive, display and visualize them along with global satellite observations. Since its inception twenty years ago, the Web and database system has been upgraded periodically to accommodate the changes in technology and the steady growth of GLOBE's education community and collection of observations. Recently, near the end-of-life of the system hardware, new commercial computer platform options were explored and a decision made to utilize Cloud services. Now the GLOBE DIS has been fully deployed and maintained using Amazon Cloud services for over two years now. This paper reviews the early risks, actual challenges, and some unexpected findings as a result of the GLOBE DIS migration. We describe the plans, cost drivers and estimates, highlight adjustments that were made and suggest improvements. We present the trade studies for provisioning, for load balancing, networks, processing , storage, as well as production, staging and backup systems. We outline the migration team's skills and required level of effort for transition, and resulting changes in the overall maintenance and operations activities. Examples include incremental adjustments to processing capacity and frequency of backups, and efforts previously expended on hardware maintenance that were refocused onto application-specific enhancements.
Optimized Heat Pipe Backup Cooling System Tested with a Stirling Convertor
NASA Technical Reports Server (NTRS)
Schwendeman, Carl L.; Tarau, Calin; Schifer, Nicholas A.; Anderson, William G.; Garner, Scott
2016-01-01
In a Stirling Radioisotope Power System (RPS), heat must be continuously removed from the General Purpose Heat Source (GPHS) modules to maintain the modules and surrounding insulation at acceptable temperatures. The Stirling convertor normally provides this cooling. If the Stirling convertor stops in the current system, the insulation is designed to spoil, preventing damage to the GPHS at the cost of an early termination of the mission. An alkali-metal variable conductance heat pipe (VCHP) can be used to passively allow multiple stops and restarts of the Stirling convertor by bypassing the heat during stops. In a previous NASA Small Business Innovation Research (SBIR) Program, Advanced Cooling Technologies, Inc. (ACT) developed a series of sodium VCHPs as backup cooling systems for the Stirling RPS. In 2012, one of these VCHPs was successfully tested at NASA Glenn Research Center with a Stirling convertor as an Advanced Stirling Radioisotope Generator (ASRG) backup cooling system. The prototype; however, was not optimized and did not reflect the final heat rejection path. ACT through further funding has developed a semioptimized prototype with the finalized heat path for testing at Glenn with a Stirling convertor. The semioptimized system features a two-phase radiator and is significantly smaller and lighter than the prior prototype to reflect a higher level of flight readiness. The VCHP is designed to activate and remove heat from the GPHS during stoppage with a small temperature increase from the nominal vapor temperature. This small temperature increase from nominal is low enough to avoid risking standard ASRG operation and spoiling of the multilayer insulation (MLI). The VCHP passively allows the Stirling convertor to be turned off multiple times during a mission with potentially unlimited off durations. Having the ability to turn the Stirling off allows for the Stirling to be reset and reduces vibrations on the platform during sensitive measurements or procedures. This paper presents the design of the VCHP and its test results with a Stirling convertor at Glenn. Tests were carried for multiple on and off cycles to demonstrate repeatability. The impacts associated with the addition of the VCHP to the system are also addressed in terms of mass and additional heat losses due to the presence of the VCHP.
Solar power satellite system definition study. Volume 5: Space transportation analysis, phase 3
NASA Technical Reports Server (NTRS)
1980-01-01
A small Heavy Lift Launch Vehicle (HLLV) for the Solar Power Satellites (SPS) System was analyzed. It is recommended that the small HLLV with a payload of 120 metric tons be adopted as the SPS launch vehicle. The reference HLLV, a shuttle-derived option with a payload of 400 metric tons, should serve as a backup and be examined further after initial flight experience. The electric orbit transfer vehicle should be retained as the reference orbit-to-orbit cargo system.
Selection of combined water electrolysis and resistojet propulsion for Space Station Freedom
NASA Technical Reports Server (NTRS)
Schmidt, George R.
1988-01-01
An analytical rationale is presented for the configuration of the NASA Space Station's two-element propulsion system, and attention is given to the cost benefits accruing to this system over the Space Station's service life. The principal system element uses gaseous oxygen and hydrogen obtained through water electrolysis to furnish attitude control, backup attitude control, and contingency maneuvering. The secondary element uses resistojets to augment Space Station reboost through the acceleration of waste gases in the direction opposite the Station's flight path.
Zinc Bromide Flow Battery Installation for Islanding and Backup Power
2016-09-18
ability to control the generation has become more difficult with the increase of renewable energy systems such as solar photovoltaics ( PV ) and wind... PV and Inverter Room Building 6311 Rooftop Solar PV 30kW 232kW STC PV Array B5-PS2T33 Pad Switchboard ZnBr Energy Storage System (ESS) PowerBoxEnergy...Agreement • 1.5 MW of Photovoltaic • PV Parking lot lights • 24 Solar Thermal systems including the Combat Training Tank (Pool) Energy/Water Efficiency
NASA Technical Reports Server (NTRS)
Flowers, George T.
1995-01-01
Progress made in the current year is listed, and the following papers are included in the appendix: Steady-State Dynamic Behavior of an Auxiliary Bearing Supported Rotor System; Dynamic Behavior of a Magnetic Bearing Supported Jet Engine Rotor with Auxiliary Bearings; Dynamic Modelling and Response Characteristics of a Magnetic Bearing Rotor System with Auxiliary Bearings; and Synchronous Dynamics of a Coupled Shaft/Bearing/Housing System with Auxiliary Support from a Clearance Bearing: Analysis and Experiment.
A soft actuation system for segmented reflector articulation and isolation
NASA Technical Reports Server (NTRS)
Agronin, Michael L.; Jandura, Louise
1990-01-01
Segmented reflectors have been proposed for space based applications such as optical communication and large diameter telescopes. An actuation system for mirrors in a space based segmented mirror array was developed as part of NASA's Precision Segmented Reflector program. The actuation system, called the Articulated Panel Module (APM), provides 3 degrees of freedom mirror articulation, gives isolation from structural motion, and simplifies space assembly of the mirrors to the reflector backup truss. A breadboard of the APM was built and is described.
Satellite services system analysis study. Volume 1: Executive summary
NASA Technical Reports Server (NTRS)
1981-01-01
Service requirements are considered. Topics include development of on-orbit operations scenarios, service equipment summary, crew interaction, and satellite features facilitating servicing. Service equipment concepts are considered. Topics include payload deployment, close proximity retrieval, on-orbit servicing, backup/contingency, delivery/retrieval of high energy payloads, Earth return, optional service, and advanced capabilities. Program requirements are assessed.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-12-15
... battery, replacing the supplement pilot's operating handbook and FAA approved airplane flight manual, and replacing the FADEC backup battery every 12 calendar months. This proposed AD was prompted by an incident... allow the FADEC to shut down or reset if the main battery is depleted and the electrical charging system...
Test fixture design for boron-aluminum and beryllium test panels
NASA Technical Reports Server (NTRS)
Breaux, C. G.
1973-01-01
A detailed description of the test fixture design and the backup analysis of the fixture assembly and its components are presented. The test fixture is required for the separate testing of two boron-aluminum and two beryllium compression panels. This report is presented in conjunction with a complete set of design drawings on the test fixture system.
21 CFR 111.35 - Under this subpart D, what records must you make and keep?
Code of Federal Regulations, 2013 CFR
2013-04-01
..., and any other contact surfaces that are used to manufacture, package, label, or hold components or... current software is not able to retrieve such records) and of data entered into computer systems that you use to manufacture, package, label, or hold dietary supplements. (i) Your backup file (e.g., a hard...
21 CFR 111.35 - Under this subpart D, what records must you make and keep?
Code of Federal Regulations, 2010 CFR
2010-04-01
..., and any other contact surfaces that are used to manufacture, package, label, or hold components or... current software is not able to retrieve such records) and of data entered into computer systems that you use to manufacture, package, label, or hold dietary supplements. (i) Your backup file (e.g., a hard...
21 CFR 111.35 - Under this subpart D, what records must you make and keep?
Code of Federal Regulations, 2011 CFR
2011-04-01
..., and any other contact surfaces that are used to manufacture, package, label, or hold components or... current software is not able to retrieve such records) and of data entered into computer systems that you use to manufacture, package, label, or hold dietary supplements. (i) Your backup file (e.g., a hard...
Trusted computation through biologically inspired processes
NASA Astrophysics Data System (ADS)
Anderson, Gustave W.
2013-05-01
Due to supply chain threats it is no longer a reasonable assumption that traditional protections alone will provide sufficient security for enterprise systems. The proposed cognitive trust model architecture extends the state-of-the-art in enterprise anti-exploitation technologies by providing collective immunity through backup and cross-checking, proactive health monitoring and adaptive/autonomic threat response, and network resource diversity.
Satellite services system analysis study. Volume 4: Service equipment concepts
NASA Technical Reports Server (NTRS)
1981-01-01
Payload deployment equipment is discussed, including payload separation, retention structures, the remote manipulator system, tilt tables, the payload installation and deployment aid, the handling and positioning aid, and spin tables. Close proximity retrieval, and on-orbit servicing equipment is discussed. Backup and contingency equipment is also discussed. Delivery and retrieval of high-energy payloads are considered. Earth return equipment, the aft flight deck, optional, and advanced equipment are also discussed.
Fault recovery for real-time, multi-tasking computer system
NASA Technical Reports Server (NTRS)
Hess, Richard (Inventor); Kelly, Gerald B. (Inventor); Rogers, Randy (Inventor); Stange, Kent A. (Inventor)
2011-01-01
System and methods for providing a recoverable real time multi-tasking computer system are disclosed. In one embodiment, a system comprises a real time computing environment, wherein the real time computing environment is adapted to execute one or more applications and wherein each application is time and space partitioned. The system further comprises a fault detection system adapted to detect one or more faults affecting the real time computing environment and a fault recovery system, wherein upon the detection of a fault the fault recovery system is adapted to restore a backup set of state variables.
Experiment M-6: Bone Demineralization
NASA Technical Reports Server (NTRS)
Mack, Pauline B.; Vose, George; Vogt, Fred B.; LaChance, Paul A.
1966-01-01
Densitometric evaluations of serial radiographs of "normal" subjects have often shown rather frequent changes in bone mass within relatively short periods of time. For this reason it was decided to make two pre-flight and two post flight radiographs of the Gemini V backup crew. In comparing the changes observed preflight and post flight as the conventional os calcis scanning site between the two crews, it was found that no changes greater than 4 percent were evident in either member of the backup crew. In comparing the changes observed preflight and postflight as the conventional o calcis scanning site between the two crews, it was found that no changes greater than 4 percent were evident in either member of the backup crew. This is in contract to the 15.1 and 8.9 percent losses observed in the prime crew. It has long been known that the skeletal system experiences a general loss of mineral under immobilization or extended bed rest. However, in both Gemini IV and Gemini V studies, bone mass losses were greater in both the os calcis and phalanx than were shown by the TWU bed-rest subjects during the same period of time. Although the bone mass losses in the 8-day Gemini V flight were generally greater than in the 4-day Gemini IV flight, the information to date is still insufficient to conclude that the losses tend to progress linearly with time, or whether a form of physiological adaptation may occur in longer space flights.
Fuel Cell Backup Power Geographical Visualization Map (Fact Sheet)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
2012-12-01
This NREL Hydrogen and Fuel Cell Technical Highlight describes a time-lapse geographical visualization map of early market use of fuel cells for telecommunications backup power. The map synthesizes data being analyzed by NREL's Technology Validation team for the U.S. Department of Energy (DOE) Fuel Cell Technologies Program with DOE's publicly available annual summaries of electric disturbance events.
95. VIEW OF SOUTHWEST CORNER OF LANDLINE INSTRUMENTATION ROOM (106), ...
95. VIEW OF SOUTHWEST CORNER OF LANDLINE INSTRUMENTATION ROOM (106), LSB (BLDG. 770). BATTERY RACK FOR BACKUP BOOSTER POWER ON LEFT; BATTERY RACK FOR BACKUP AEROSPACE GROUND EQUIPMENT (AGE) POWER ON RIGHT. BATTERY CHARGER IS RIGHT OF BATTERY RACKS. - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 West, Napa & Alden Roads, Lompoc, Santa Barbara County, CA
NASA Astrophysics Data System (ADS)
Arcidiacono, V.; Corsi, S.; Iliceto, A.; Previ, A.; Taschini, A.
Design features and goals of the photovoltaic array power system for Alicudi Island hamlets are described. The array will have two 40 kWe sections, a 3 kAh battery system, an inverter to assure three-phase, ac current, a data acquisition system, and a 60 kVA diesel back-up system. The semi-arid conic volcanic island has terraces and a slope ideally suited to installation of the array. A computer simulation was developed to optimize the output and load profile matching using historical insolation data. A block diagram is provided of the electricity distribution network.
A qualitative analysis of how advanced practice nurses use clinical decision support systems.
Weber, Scott
2007-12-01
The purpose of this study was to generate a grounded theory that will reflect the experiences of advanced practice nurses (APNs) working as critical care nurse practitioners (NPs) and clinical nurse specialists (CNS) with computer-based decision-making systems. A study design using grounded theory qualitative research methods and convenience sampling was employed in this study. Twenty-three APNs (13 CNS and 10 NPs) were recruited from 16 critical care units located in six large urban medical centers in the U.S. Midwest. Single-structured in-depth interviews with open-ended audio-taped questions were conducted with each APN. Through this process, APNs defined what they consider to be relevant themes and patterns of clinical decision system use in their critical care practices, and they identified the interrelatedness of the conceptual categories that emerged from the results. Data were analyzed using the constant comparative analysis method of qualitative research. APN participants were predominantly female, white/non-Hispanic, had a history of access to the clinical decision system used in their critical care settings for an average of 14 months, and had attended a formal training program to learn how to use clinical decision systems. "Forecasting decision outcomes," which was defined as the voluntary process employed to forecast the outcomes of patient care decisions in critical care prior to actual decision making, was the core variable describing system use that emerged from the responses. This variable consisted of four user constructs or components: (a) users' perceptions of their initial system learning experience, (b) users' sense of how well they understand how system technology works, (c) users' understanding of how system inferences are created or derived, and (d) users' relative trust of system-derived data. Each of these categories was further described through the grounded theory research process, and the relationships between the categories were identified. The findings of this study suggest that the main reason critical care APNs choose to integrate clinical decision systems into their practices is to provide an objective, scientifically derived, technology-based backup for human forecasting of the outcomes of patient care decisions prior to their actual decision making. Implications for nursing, health care, and technology research are presented.
Economics of Direct Hydrogen Polymer Electrolyte Membrane Fuel Cell Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mahadevan, Kathyayani
Battelle's Economic Analysis of PEM Fuel Cell Systems project was initiated in 2003 to evaluate the technology and markets that are near-term and potentially could support the transition to fuel cells in automotive markets. The objective of Battelle?s project was to assist the DOE in developing fuel cell systems for pre-automotive applications by analyzing the technical, economic, and market drivers of direct hydrogen PEM fuel cell adoption. The project was executed over a 6-year period (2003 to 2010) and a variety of analyses were completed in that period. The analyses presented in the final report include: Commercialization scenarios for stationarymore » generation through 2015 (2004); Stakeholder feedback on technology status and performance status of fuel cell systems (2004); Development of manufacturing costs of stationary PEM fuel cell systems for backup power markets (2004); Identification of near-term and mid-term markets for PEM fuel cells (2006); Development of the value proposition and market opportunity of PEM fuel cells in near-term markets by assessing the lifecycle cost of PEM fuel cells as compared to conventional alternatives used in the marketplace and modeling market penetration (2006); Development of the value proposition of PEM fuel cells in government markets (2007); Development of the value proposition and opportunity for large fuel cell system application at data centers and wastewater treatment plants (2008); Update of the manufacturing costs of PEM fuel cells for backup power applications (2009).« less
NASA Astrophysics Data System (ADS)
Badea, G.; Felseghi, R. A.; Aşchilean, I.; Rǎboacǎ, S. M.; Şoimoşan, T.
2017-12-01
The concept of sustainable development aims to meet the needs of the present without compromising the needs of future generations. In achieving the desideratum "low-carbon energy system", in the domain of energy production, the use of innovative low-carbon technologies providing maximum efficiency and minimum pollution is required. Such technology is the fuel cell; as these will be developed, it will become a reality to obtain the energy based on hydrogen. Thus, hydrogen produced by electrolysis of water using different forms of renewable resources becomes a secure and sustainable energy alternative. In this context, in the present paper, a comparative study of two different hybrid power generation systems for residential building placed in Cluj-Napoca was made. In these energy systems have been integrated renewable energies (photovoltaic panels and wind turbine), backup and storage system based on hydrogen (fuel cell, electrolyser and hydrogen storage tank), and, respectively, backup and storage system based on traditional technologies (diesel generator and battery). The software iHOGA was used to simulate the operating performance of the two hybrid systems. The aim of this study was to compare energy, environmental and economic performances of these two systems and to define possible future scenarios of competitiveness between traditional and new innovative technologies. After analyzing and comparing the results of simulations, it can be concluded that the fuel cells technology along with hydrogen, integrated in a hybrid system, may be the key to energy production systems with high energy efficiency, making possible an increased capitalization of renewable energy which have a low environmental impact.
Zinc Bromide Flow Battery Installation for Islanding and Backup Power
2017-08-09
predictably is in place. The ability to control generation has become more difficult with the increase of RE systems such as solar PV and wind turbines ...Both PV and wind systems generate power based on unpredictable cycles of nature. At very low levels of RE penetration the grid can be balanced by...Page Intentionally Left Blank 15 5.0 TEST DESIGN This goal of this demonstration was to solve two main problems . The first
2015-11-01
provided by a stand-alone desktop or hand held computing device. This introduces into the discussion a large number of mobile , tactical command...control, communications, and computer (C4) systems across the Services. A couple of examples are mobile command posts mounted on the back of an M1152... infrastructure (DCPI). This term encompasses on-site backup generators, switchgear, uninterruptible power supplies (UPS), power distribution units
Satellite freeze forecast system
NASA Technical Reports Server (NTRS)
Martsolf, J. D. (Principal Investigator)
1983-01-01
Provisions for back-up operations for the satellite freeze forecast system are discussed including software and hardware maintenance and DS/1000-1V linkage; troubleshooting; and digitized radar usage. The documentation developed; dissemination of data products via television and the IFAS computer network; data base management; predictive models; the installation of and progress towards the operational status of key stations; and digital data acquisition are also considered. The d addition of dew point temperature into the P-model is outlined.
Aircraft Enroute Command and Control Comms Redesign Mechanical Documentation
2015-12-01
and power equipment is secured. Custom racks , with 8 server rack bays, are mounted to the pallet, with 2 desk stations for equipment operators...conventional rack equipment. Equipment in the original system was larger and heavier than the new equipment selected for the NG-JC2S. Battery backup was...purposes. The equipment also needed to be easily removable in the event of equipment failure. Surplus rack space available in the NG-JC2S system allowed
Software dependability in the Tandem GUARDIAN system
NASA Technical Reports Server (NTRS)
Lee, Inhwan; Iyer, Ravishankar K.
1995-01-01
Based on extensive field failure data for Tandem's GUARDIAN operating system this paper discusses evaluation of the dependability of operational software. Software faults considered are major defects that result in processor failures and invoke backup processes to take over. The paper categorizes the underlying causes of software failures and evaluates the effectiveness of the process pair technique in tolerating software faults. A model to describe the impact of software faults on the reliability of an overall system is proposed. The model is used to evaluate the significance of key factors that determine software dependability and to identify areas for improvement. An analysis of the data shows that about 77% of processor failures that are initially considered due to software are confirmed as software problems. The analysis shows that the use of process pairs to provide checkpointing and restart (originally intended for tolerating hardware faults) allows the system to tolerate about 75% of reported software faults that result in processor failures. The loose coupling between processors, which results in the backup execution (the processor state and the sequence of events) being different from the original execution, is a major reason for the measured software fault tolerance. Over two-thirds (72%) of measured software failures are recurrences of previously reported faults. Modeling, based on the data, shows that, in addition to reducing the number of software faults, software dependability can be enhanced by reducing the recurrence rate.
Kathpalia, S K
2016-04-01
India was one of the first countries to launch a formal family planning program. Initially, the main thrust of the program was on sterilization but subsequently it has got evolved and now the stress is to bring about awareness of contraception and make informed choices. Emergency contraception has been included in its armamentarium. This study was conducted to find out about the awareness among the cases who report for induced abortion. A total of 784 willing cases were enrolled in the study; there were no exclusion criteria except unwillingness. A parallel group was also included consisting of their spouses. Information that was being sought about Emergency Contraception (EC) included its knowledge, details of administration, and availability. Of the 784 cases, a large number, 742 (94.6%), underwent first trimester abortion and only 42 (5.3%) underwent second trimester abortion. 286 (36.4%) patients had not used any contraceptive. A large number had used natural methods (35.3%), like lactation, abstinence, or coitus interruptus, and 25.7% had used barrier contraception inconsistently. A very small percentage in both the groups knew about EC; more number of men knew about EC than women. Awareness about emergency contraception is low, as reported in many other studies, though it is available for many years. Awareness about contraceptives needs to be improved and emergency contraceptive should be advocated as a backup method. More efforts are required to generate awareness about regular use of effective contraception and emergency contraception if required.
Oren, Meir
2004-11-01
The world now faces the dreadful possibility of biological weapons attacks by terrorists. Healthcare systems would have to cope with such emergencies should all preemptive measures fail. Information gained from the Global Mercury exercise and the SARS outbreak has shown that containing an outbreak at the start is more effective than reacting to it once it has spread and that containment should be treated both nationally and internationally. On the national level this entails developing rapid and effective methods to detect and identify infected cases, and implementing isolation and control measures to lower the risk of further transmission of the disease while assuring the safety of medical teams and laboratory workers. Strategic contingency plans should incorporate well-defined procedures for hospitalization and isolation of patients, providing regional backup of medical personnel and equipment and maintaining close cooperation between the various bodies in the healthcare system. Quarantine is an effective containment measure, especially if voluntarily imposed. Modern communication systems can help by sending professional teams timely instructions and providing the public with information to reduce panic and stress during quarantine procedures. Informing the public poses a dilemma: finding a balance between giving advance warning of an imminent epidemic outbreak and ascertaining the likelihood of its occurrence. Containment of international bioterrorist attacks depends entirely on close international cooperation to implement national and international strategic contingency plans with free exchange of information and recognition of procedures.
Standby-battery autonomy versus power quality
NASA Astrophysics Data System (ADS)
Bitterlin, Ian F.
Batteries are used in a wide variety of applications as an energy store to bridge gaps in the primary source of supplied power for a given period of time. In some cases this bridging time, the battery's "autonomy", is fixed by local legislation but it is also often set by historically common practices. However, even if common practice dictates a long autonomy time, we are entering a new era of "cost and benefit realism" underpinned by environmentally friendly policies and we should challenge these historical practices at every opportunity if it can lead to resource and cost savings. In some cases the application engineer has no choice in the design autonomy; either follow a piece of local legislation (e.g. 4 h autonomy for a "life safety" application), or actually work out what is needed! An example of the latter would be for a remote site, off-grid, using integrated wind/solar power (without emergency generator back-up) where you may have to design-in several days' battery autonomy. This short paper proposes that a battery's autonomy should be related to the time expected for the system to be without the primary power source, balanced by the capital costs and commercial risk of power failure. To discuss this we shall consider the factors in selecting the autonomy time and other related aspects for high voltage battery systems used in facility-wide uninterruptible power supply (UPS) systems.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-10-04
...; exposure to domestic violence; housing status prior to shelter entry; homelessness history; barriers to... failures or disasters. Only encrypted versions of the data will be copied to the backup media. Unencrypted data will never be stored on a laptop or on a movable media such as CDs, diskettes, or USB flash drives...
The USL NASA PC R and D development environment standards
NASA Technical Reports Server (NTRS)
Dominick, Wayne D. (Editor); Moreau, Dennis R.
1984-01-01
The development environment standards which have been established in order to control usage of the IBM PC/XT development systems and to prevent interference between projects being currently developed on the PC's are discussed. The standards address the following areas: scheduling PC resources; login/logout procedures; training; file naming conventions; hard disk organization; diskette care; backup procedures; and copying policies.
ERIC Educational Resources Information Center
Johnston, Jill; Kant, Sashi; Gysbers, Vanessa; Hancock, Dale; Denyer, Gareth
2014-01-01
Despite many apparent advantages, including security, back-up, remote access, workflow, and data management, the use of electronic laboratory notebooks (ELNs) in the modern research laboratory is still developing. This presents a challenge to instructors who want to give undergraduate students an introduction to the kinds of data curation and…
40 CFR 86.1310-90 - Exhaust gas sampling and analytical system; diesel engines.
Code of Federal Regulations, 2012 CFR
2012-07-01
... petroleum fuel or a non-heated flame ionization detector may be used. (3) Methanol-fueled engines require...); or (iii) Omitting the duct and performing the exhaust gas dilution function at the engine exhaust... two steps to a temperature never greater than 125 °F (51.7 °C) at the primary sample filter. A backup...
40 CFR 86.1310-90 - Exhaust gas sampling and analytical system; diesel engines.
Code of Federal Regulations, 2013 CFR
2013-07-01
... petroleum fuel or a non-heated flame ionization detector may be used. (3) Methanol-fueled engines require...); or (iii) Omitting the duct and performing the exhaust gas dilution function at the engine exhaust... two steps to a temperature never greater than 125 °F (51.7 °C) at the primary sample filter. A backup...
The AP1000{sup R} nuclear power plant innovative features for extended station blackout mitigation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vereb, F.; Winters, J.; Schulz, T.
2012-07-01
Station Blackout (SBO) is defined as 'a condition wherein a nuclear power plant sustains a loss of all offsite electric power system concurrent with turbine trip and unavailability of all onsite emergency alternating current (AC) power system. Station blackout does not include the loss of available AC power to buses fed by station batteries through inverters or by alternate AC sources as defined in this section, nor does it assume a concurrent single failure or design basis accident...' in accordance with Reference 1. In this paper, the innovative features of the AP1000 plant design are described with their operation inmore » the scenario of an extended station blackout event. General operation of the passive safety systems are described as well as the unique features which allow the AP1000 plant to cope for at least 7 days during station blackout. Points of emphasis will include: - Passive safety system operation during SBO - 'Fail-safe' nature of key passive safety system valves; automatically places the valve in a conservatively safe alignment even in case of multiple failures in all power supply systems, including normal AC and battery backup - Passive Spent Fuel Pool cooling and makeup water supply during SBO - Robustness of AP1000 plant due to the location of key systems, structures and components required for Safe Shutdown - Diverse means of supplying makeup water to the Passive Containment Cooling System (PCS) and the Spent Fuel Pool (SFP) through use of an engineered, safety-related piping interface and portable equipment, as well as with permanently installed onsite ancillary equipment. (authors)« less
12. Detail of clutch and backup gasoline engine for powering ...
12. Detail of clutch and backup gasoline engine for powering Stoney gates. Clutch mechanism manufactured by Baldridge Machine Company, Detroit, Michigan, ca. 1910. Instrument to the left records volume of flow through headworks. View looking south towards Stoney gates. Photo by Jet Lowe, HAER, 1989. - Puget Sound Power & Light Company, White River Hydroelectric Project, 600 North River Avenue, Dieringer, Pierce County, WA
Payload specialists in training for STS 51-L in mockup & integration lab
1986-01-09
S86-25254 (January 1986) --- Payload specialists in training for STS-51L take a break in shuttle emergency egress training at the Johnson Space Center's (JSC) Shuttle Mock-up and Integration Laboratory. Left to right are Gregory Jarvis of Hughes, Sharon Christa McAuliffe and Barbara Morgan of the Teacher-in-Space Project. McAuliffe was selected as NASA's first citizen observer in the Space Shuttle Program and Morgan was named her backup. The photo was taken by Keith Meyers of the New York Times. EDITOR?S NOTE: The STS-51L crew members lost their lives in the space shuttle Challenger accident moments after launch on Jan. 28, 1986 from the Kennedy Space Center (KSC). Photo credit: NASA
Zhang, Zhe; Kong, Xiangping; Yin, Xianggen; Yang, Zengli; Wang, Lijun
2014-01-01
In order to solve the problems of the existing wide-area backup protection (WABP) algorithms, the paper proposes a novel WABP algorithm based on the distribution characteristics of fault component current and improved Dempster/Shafer (D-S) evidence theory. When a fault occurs, slave substations transmit to master station the amplitudes of fault component currents of transmission lines which are the closest to fault element. Then master substation identifies suspicious faulty lines according to the distribution characteristics of fault component current. After that, the master substation will identify the actual faulty line with improved D-S evidence theory based on the action states of traditional protections and direction components of these suspicious faulty lines. The simulation examples based on IEEE 10-generator-39-bus system show that the proposed WABP algorithm has an excellent performance. The algorithm has low requirement of sampling synchronization, small wide-area communication flow, and high fault tolerance. PMID:25050399
High pressure water electrolysis for space station EMU recharge
NASA Technical Reports Server (NTRS)
Lance, Nick; Puskar, Michael; Moulthrop, Lawrence; Zagaja, John
1988-01-01
A high pressure oxygen recharge system (HPORS), is being developed for application on board the Space Station. This electrolytic system can provide oxygen at up to 6000 psia without a mechanical compressor. The Hamilton standard HPORS based on a solid polymer electrolyte system is an extension of the much larger and succesful 3000 psia system of the U.S. Navy. Cell modules have been successfully tested under conditions beyond which spacecraft may encounter during launch. The control system with double redundancy and mechanical backups for all electronically controlled components is designed to ensure a safe shutdown.
Huang, Li; Roberts, Calum T; Manley, Brett J; Owen, Louise S; Davis, Peter G; Dalziel, Kim M
2018-05-01
To compare the cost-effectiveness of 2 common "noninvasive" modes of respiratory support for infants born preterm. An economic evaluation was conducted as a component of a multicenter, randomized control trial from 2013 to 2015 enrolling infants born preterm at ≥28 weeks of gestation with respiratory distress, <24 hours old, who had not previously received endotracheal intubation and mechanical ventilation or surfactant. The economic evaluation was conducted from a healthcare sector perspective and the time horizon was from birth until death or first discharge. The cost-effectiveness of continuous positive airway pressure (CPAP) vs high-flow with "rescue" CPAP backup and high-flow without rescue CPAP backup (as sole primary support) were analyzed by using the hospital cost of inpatient stay in a tertiary center and the rates of endotracheal intubation and mechanical ventilation during admission. Hospital inpatient cost records for 435 infants enrolled in all Australian centers were obtained. With "rescue" CPAP backup, an incremental cost-effectiveness ratio was estimated of A$179 000 (US$123 000) per ventilation avoided if CPAP was used compared with high flow. Without rescue CPAP backup, cost per ventilation avoided was A$7000 (US$4800) if CPAP was used compared with high flow. As sole primary support, CPAP is highly likely to be cost-effective compared with high flow. Neonatal units choosing to use only one device should apply CPAP as primary respiratory support. Compared with high-flow with rescue CPAP backup, CPAP is unlikely to be cost-effective if willingness to pay per ventilation avoided is less than A$179 000 (US$123 000). Copyright © 2018 Elsevier Inc. All rights reserved.
Multicast backup reprovisioning problem for Hamiltonian cycle-based protection on WDM networks
NASA Astrophysics Data System (ADS)
Din, Der-Rong; Huang, Jen-Shen
2014-03-01
As networks grow in size and complexity, the chance and the impact of failures increase dramatically. The pre-allocated backup resources cannot provide 100% protection guarantee when continuous failures occur in a network. In this paper, the multicast backup re-provisioning problem (MBRP) for Hamiltonian cycle (HC)-based protection on WDM networks for the link-failure case is studied. We focus on how to recover the protecting capabilities of Hamiltonian cycle against the subsequent link-failures on WDM networks for multicast transmissions, after recovering the multicast trees affected by the previous link-failure. Since this problem is a hard problem, an algorithm, which consists of several heuristics and a genetic algorithm (GA), is proposed to solve it. The simulation results of the proposed method are also given. Experimental results indicate that the proposed algorithm can solve this problem efficiently.
NASA Astrophysics Data System (ADS)
Liao, Luhua; Li, Lemin; Wang, Sheng
2006-12-01
We investigate the protection approach for dynamic multicast traffic under shared risk link group (SRLG) constraints in meshed wavelength-division-multiplexing optical networks. We present a shared protection algorithm called dynamic segment shared protection for multicast traffic (DSSPM), which can dynamically adjust the link cost according to the current network state and can establish a primary light-tree as well as corresponding SRLG-disjoint backup segments for a dependable multicast connection. A backup segment can efficiently share the wavelength capacity of its working tree and the common resources of other backup segments based on SRLG-disjoint constraints. The simulation results show that DSSPM not only can protect the multicast sessions against a single-SRLG breakdown, but can make better use of the wavelength resources and also lower the network blocking probability.
NASA Astrophysics Data System (ADS)
Wang, Lin; Wu, Wenqi; Wei, Guo; Lian, Junxiang; Yu, Ruihang
2018-05-01
The shipboard redundant rotational inertial navigation system (RINS) configuration, including a dual-axis RINS and a single-axis RINS, can satisfy the demand of marine INSs of especially high reliability as well as achieving trade-off between position accuracy and cost. Generally, the dual-axis RINS is the master INS, and the single-axis RINS is the hot backup INS for high reliability purposes. An integrity monitoring system performs a fault detection function to ensure sailing safety. However, improving the accuracy of the backup INS in case of master INS failure has not been given enough attention. Without the aid of any external information, a systematic bias collaborative measurement method based on an augmented Kalman filter is proposed for the redundant RINSs. Estimates of inertial sensor biases can be used by the built-in integrity monitoring system to monitor the RINS running condition. On the other hand, a position error prediction model is designed for the single-axis RINS to estimate the systematic error caused by its azimuth gyro bias. After position error compensation, the position information provided by the single-axis RINS still remains highly accurate, even if the integrity monitoring system detects a dual-axis RINS fault. Moreover, use of a grid frame as a navigation frame makes the proposed method applicable in any area, including the polar regions. Semi-physical simulation and experiments including sea trials verify the validity of the method.
NASA Astrophysics Data System (ADS)
Wohland, Jan; Witthaut, Dirk
2017-04-01
Electricity systems with a high penetration of renewables are strongly affected by weather patterns. Due to the variability of the climate system, a substantial fraction of energy supply needs to be provided by dispatchable power plants even if the consumption is on average balanced by renewables (e.g. Rodriguez et al. [2014]). In an interconnected system like the European electricity grid, benefits can arise from balancing generation mismatches spatially as long as overproduction in one region coincides with lack of generation in another region. These benefits might change as the climate changes and we thus investigate alterations of correlations between wind timeseries and Backup energy requirements. Our analysis is based on a five member model-ensemble from the EUROCORDEX initiative and we focus on onshore wind energy. We use the highest temporal (3h) and spatial (0.11°) resolution available to capture the intermittent and spatially diverse nature of renewable generation. In view of inter-model spread and other uncertainties, we use the strong climate change scenario rcp8.5 in order to obtain a high signal-to-noise ratio. We argue that rcp8.5 is best suited to reveal interesting interactions between climate change and renewable electricity system despite the fact that is in contradiction to the UNFCCC temperature goals (e.g. Schleussner et al. [2016]). We report spatially inhomogeneous alterations of correlations. In particular, we find increasing correlations between central and northern European states and decreasing correlations at the south-western and south-eastern margins of Europe. This hints to a lowering of balancing potentials within central and northern Europe due to climate change. A possible explanation might be associated to polar amplification and increasing frequencies of blocking events (Coumou [2015]). Moreover, we compute wind energy generation using a single-turbine model and a semi-random deployment procedure as developed in Monforti et al. [2016]. In combination with ENTSO-E load data and validated solar generation timeseries from Renewable Ninja (Pfenninger and Staffell [2016]), we calculate backup energy needs in Europe and analyze the potential of cooperation between countries to lower them. We find increases in European backup energy needs throughout the 21st century which are robust across the 5 climate models considered.
F-8 DFBW simulating STS contro l system - Pilot-induced oscillation (PIO) on landing
NASA Technical Reports Server (NTRS)
1978-01-01
From 1972 to 1985 the NASA Dryden Flight Research Center conducted flight research with an F-8C employing the first digital fly-by-wire flight control system without a mechanical back up. The decision to replace all mechanical control linkages to rudder, ailerons, and other flight control surfaces was made for two reasons. First, it forced the research engineers to focus on the technology and issues that were truly critical for a production fly-by-wire aircraft. Secondly, it would give industry the confidence it needed to apply the technology--confidence it would not have had if the experimental system relied on a mechanical back up. In the first few decades of flight, pilots had controlled aircraft through direct force--moving control sticks and rudder pedals linked to cables and pushrods that pivoted control surfaces on the wings and tails. As engine power and speeds increased, more force was needed and hydraulically boosted controls emerged. Soon, all high-performance and large aircraft had hydraulic-mechanical flight-control systems. These conventional flight control systems restricted designers in the configuration and design of aircraft because of the need for flight stability. As the electronic era grew in the 1960s, so did the idea of aircraft with electronic flight-control systems. Wires replacing mechanical devices would give designers greater flexibility in configuration and in the size and placement of components such as tail surfaces and wings. A fly-by-wire system also would be smaller, more reliable, and in military aircraft, much less vulnerable to battle damage. A fly-by-wire aircraft would also be much more responsive to pilot control inputs. The result would be more efficient, safer aircraft with improved performance and design. The Aircraft By the late 1960s, engineers at Dryden began discussing how to modify an aircraft and create a fly-by-wire testbed. Support for the concept at NASA Headquarters came from Neil Armstrong, former research pilot at Dryden. He served in the Office of Advanced Research and Technology following his historic Apollo 11 lunar landing and knew electronic control systems from his days training in and operating the lunar module. Armstrong supported the proposed Dryden project and backed the transfer of an F-8C Crusader from the U.S. Navy to NASA to become the Digital Fly-By-Wire (DFBW) research aircraft. It was given the tail number 'NASA 802.' Wires from the control stick in the cockpit to the control surfaces on the wings and tail surfaces replaced the entire mechanical flight-control system in the F-8. The heart of the system was an off-the-shelf backup Apollo digital flight-control computer and inertial sensing unit, which transmitted pilot inputs to the actuators on the control surfaces. On May 25, 1972, the highly modified F-8 became the first aircraft to fly completely dependent upon an electronic flight-control system without any mechanical backup. The pilot was Gary Krier. The first phase of the DFBW program validated the fly-by-wire concept and quickly showed that a refined system, especially in large aircraft, would greatly enhance flying qualities by sensing motion changes and applying pilot inputs instantaneously. The Phase 1 system had a backup analog fly-by-wire system in the event of a failure in the Apollo computer unit, but it was never necessary to use the system in flight. In a joint program carried out with the Langley Research Center in the second phase of research, the original Apollo system was replaced with a triply redundant digital system. It would provide backup computer capabilities if a failure occurred. The DFBW program lasted 13 years. The final research flight, the 210th of the program, was made April 2, 1985, with Dryden Research Pilot Ed Schneider at the controls. Research Benefits The F-8 DFBW validated the principal concepts of the all-electric flight control systems now used in a variety of airplanes ranging from the F/A-18 to the Boeing 777 and the space shuttles. A DFBW flight control system also is used on the space shuttles. NASA 802 was the testbed for the sidestick-controller used in the F-16 fighter, the second U.S. high performance aircraft with a DFBW system. In addition to pioneering the space shuttle's fly-by-wire flight-control system, NASA 802 was the testbed that explored Pilot Induced Oscillations (PIO) and validated methods to suppress them. PIOs occur when a pilot over-controls an aircraft and a sustained oscillation results. On the last of five free flights of the prototype Space Shuttle Enterprise during approach and landing tests in l977, a PIO developed as the vehicle settled onto the runway. The problem was duplicated with the F-8 DFBW and a series of PIO suppression filters was developed and tested on the aircraft for the shuttle program office. DFBW research carried out with NASA 802 at Dryden is now considered one of the most significant and successful aeronautical programs in NASA history. In this clip we see NASA research pilot John Manke at the controls of Dryden's F-8 Digital Fly-By-Wire aircraft as it enters a severe pilot induced oscillation or PIO just after completion of a touch-and-go landing while testing for a signal-delay-related problem that occurred during an approach to landing on the shuttle prototype Enterprise.
STS-45 backup Payload Specialist Chappell during water egress training at JSC
NASA Technical Reports Server (NTRS)
1991-01-01
STS-45 Atlantis, Orbiter Vehicle (OV) 104, backup Payload Specialist Charles R. Chappell, wearing launch and entry suit (LES), is suspended via his parachute harness above JSC's Weightless Environment Training Facility (WETF) Bldg 29 pool. Chappell will be dropped into the pool during the exercise which simulates a parachute landing into a body of water. SCUBA-equipped divers swimming in the pool will assist during the training.
NASA Technical Reports Server (NTRS)
Aquila, V.; Derrig, D.; Griffith, G.
1986-01-01
Procedures are presented that allow the user to assemble tasks, link, compile, backup the system, generate/establish/print display pages, cancel tasks in memory, and to TET an assembly task without having to enter the commands every time. A list of acronyms is provided. Software identification, payload checkout unit operating system services, data base generation, and MITRA operating procedures are also discussed.
Computer memory power control for the Galileo spacecraft
NASA Technical Reports Server (NTRS)
Detwiler, R. C.
1983-01-01
The developmental history, major design drives, and final topology of the computer memory power system on the Galileo spacecraft are described. A unique method of generating memory backup power directly from the fault current drawn during a spacecraft power overload or fault condition allows this system to provide continuous memory power. This concept provides a unique solution to the problem of volatile memory loss without the use of a battery of other large energy storage elements usually associated with uninterrupted power supply designs.
International Space Station Payload Operations Integration Center (POIC) Overview
NASA Technical Reports Server (NTRS)
Ijames, Gayleen N.
2012-01-01
Objectives and Goals: Maintain and operate the POIC and support integrated Space Station command and control functions. Provide software and hardware systems to support ISS payloads and Shuttle for the POIF cadre, Payload Developers and International Partners. Provide design, development, independent verification &validation, configuration, operational product/system deliveries and maintenance of those systems for telemetry, commanding, database and planning. Provide Backup Control Center for MCC-H in case of shutdown. Provide certified personnel and systems to support 24x7 facility operations per ISS Program. Payloads CoFR Implementation Plan (SSP 52054) and MSFC Payload Operations CoFR Implementation Plan (POIF-1006).
Using a novel technology for disaster staff notification.
Morris, Stephen C; Pelley, Janice K; Mitchell, Steven H
Notification of backup staff and determining their ability to augment frontline staff is a major component of any disaster plan. However, the communication and organization of this effort has many challenges. These include communication system overload, the disaster setting, disrupted transportation, and staffing impacts on normal operations. An optimal disaster notification system must have the ability to be modified to include all hazards and the unique environment in which the plan is being made. This article highlights a unique disaster staff notification system using a novel technology, an outside administrator, and a multilayer system of redundant communication.
System design description for portable 1,000 CFM exhauster Skids POR-007/Skid E and POR-008/Skid F
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nelson, O.D.
1998-07-25
The primary purpose of the two 1,000 CFM Exhauster Skids, POR-007-SKID E and POR-008-SKID F, is to provide backup to the waste tank primary ventilation systems for tanks 241-C-106 and 241-AY-102, and the AY-102 annulus in the event of a failure during the sluicing of tank 241-C-106 and subsequent transfer of sluiced waste to 241-AY-102. This redundancy is required since both of the tank ventilation systems have been declared as Safety Class systems.
The improved broadband Real-Time Seismic Network in Romania
NASA Astrophysics Data System (ADS)
Neagoe, C.; Ionescu, C.
2009-04-01
Starting with 2002 the National Institute for Earth Physics (NIEP) has developed its real-time digital seismic network. This network consists of 96 seismic stations of which 48 broad band and short period stations and two seismic arrays are transmitted in real-time. The real time seismic stations are equipped with Quanterra Q330 and K2 digitizers, broadband seismometers (STS2, CMG40T, CMG 3ESP, CMG3T) and strong motions sensors Kinemetrics episensors (+/- 2g). SeedLink and AntelopeTM (installed on MARMOT) program packages are used for real-time (RT) data acquisition and exchange. The communication from digital seismic stations to the National Data Center in Bucharest is assured by 5 providers (GPRS, VPN, satellite communication, radio lease line and internet), which will assure the back-up communications lines. The processing centre runs BRTT's AntelopeTM 4.10 data acquisition and processing software on 2 workstations for real-time processing and post processing. The Antelope Real-Time System is also providing automatic event detection, arrival picking, event location and magnitude calculation. It provides graphical display and reporting within near-real-time after a local or regional event occurred. Also at the data center was implemented a system to collect macroseismic information using the internet on which macro seismic intensity maps are generated. In the near future at the data center will be install Seiscomp 3 data acquisition processing software on a workstation. The software will run in parallel with Antelope software as a back-up. The present network will be expanded in the near future. In the first half of 2009 NIEP will install 8 additional broad band stations in Romanian territory, which also will be transmitted to the data center in real time. The Romanian Seismic Network is permanently exchanging real -time waveform data with IRIS, ORFEUS and different European countries through internet. In Romania, magnitude and location of an earthquake are now available within a few minutes after the earthquake occurred. One of the greatest challenges in the near future is to provide shaking intensity maps and other ground motion parameters, within 5 minutes post-event, on the Internet and GIS-based format in order to improve emergency response, public information, preparedness and hazard mitigation
Microscale air quality impacts of distributed power generation facilities.
Olaguer, Eduardo P; Knipping, Eladio; Shaw, Stephanie; Ravindran, Satish
2016-08-01
The electric system is experiencing rapid growth in the adoption of a mix of distributed renewable and fossil fuel sources, along with increasing amounts of off-grid generation. New operational regimes may have unforeseen consequences for air quality. A three-dimensional microscale chemical transport model (CTM) driven by an urban wind model was used to assess gaseous air pollutant and particulate matter (PM) impacts within ~10 km of fossil-fueled distributed power generation (DG) facilities during the early afternoon of a typical summer day in Houston, TX. Three types of DG scenarios were considered in the presence of motor vehicle emissions and a realistic urban canopy: (1) a 25-MW natural gas turbine operating at steady state in either simple cycle or combined heating and power (CHP) mode; (2) a 25-MW simple cycle gas turbine undergoing a cold startup with either moderate or enhanced formaldehyde emissions; and (3) a data center generating 10 MW of emergency power with either diesel or natural gas-fired backup generators (BUGs) without pollution controls. Simulations of criteria pollutants (NO2, CO, O3, PM) and the toxic pollutant, formaldehyde (HCHO), were conducted assuming a 2-hr operational time period. In all cases, NOx titration dominated ozone production near the source. The turbine scenarios did not result in ambient concentration enhancements significantly exceeding 1 ppbv for gaseous pollutants or over 1 µg/m(3) for PM after 2 hr of emission, assuming realistic plume rise. In the case of the datacenter with diesel BUGs, ambient NO2 concentrations were enhanced by 10-50 ppbv within 2 km downwind of the source, while maximum PM impacts in the immediate vicinity of the datacenter were less than 5 µg/m(3). Plausible scenarios of distributed fossil generation consistent with the electricity grid's transformation to a more flexible and modernized system suggest that a substantial amount of deployment would be required to significantly affect air quality on a localized scale. In particular, natural gas turbines typically used in distributed generation may have minor effects. Large banks of diesel backup generators such as those used by data centers, on the other hand, may require pollution controls or conversion to natural gas-fired reciprocal internal combustion engines to decrease nitrogen dioxide pollution.
2015-09-28
the performance of log-and- replay can degrade significantly for VMs configured with multiple virtual CPUs, since the shared memory communication...whether based on checkpoint replication or log-and- replay , existing HA ap- proaches use in- memory backups. The backup VM sits in the memory of a...efficiently. 15. SUBJECT TERMS High-availability virtual machines, live migration, memory and traffic overheads, application suspension, Java
115. VIEW OF SOUTHWEST CORNER OF LANDLINE INSTRUMENTATION ROOM (206), ...
115. VIEW OF SOUTHWEST CORNER OF LANDLINE INSTRUMENTATION ROOM (206), LSB (BLDG. 751). BATTERY RACK ON LEFT FOR BACKUP BOOSTER POWER; BATTERY RACK ON RIGHT FOR BACKUP AEROSPACE GROUND EQUIPMENT (AGE) POWER. RECTIFIER SUPPLYING PRIMARY POWER ON THE RIGHT SIDE OF THE PHOTO; BATTERY CHARGER BETWEEN RECTIFIER AND BATTERY RACKS. - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 East, Napa & Alden Roads, Lompoc, Santa Barbara County, CA
1970-04-14
S70-34986 (14 April 1970) --- A group of six astronauts and two flight controllers monitor the console activity in the Mission Operations Control Room (MOCR) of the Mission Control Center (MCC) during the problem-plagued Apollo 13 lunar landing mission. Seated, left to right, are MOCR Guidance Officer Raymond F. Teague; astronaut Edgar D. Mitchell, Apollo 14 prime crew lunar module pilot; and astronaut Alan B. Shepard Jr., Apollo 14 prime crew commander. Standing, left to right, are scientist-astronaut Anthony W. England; astronaut Joe H. Engle, Apollo 14 backup crew lunar module pilot; astronaut Eugene A. Cernan, Apollo 14 backup crew commander; astronaut Ronald E. Evans, Apollo 14 backup crew command module pilot; and M.P. Frank, a flight controller. When this picture was made, the Apollo 13 moon landing had already been canceled, and the Apollo 13 crew men were in trans-Earth trajectory attempting to bring their damaged spacecraft back home.
NASA Technical Reports Server (NTRS)
Flowers, George T.
1994-01-01
Substantial progress has been made toward the goals of this research effort in the past six months. A simplified rotor model with a flexible shaft and backup bearings has been developed. The model is based upon the work of Ishii and Kirk. Parameter studies of the behavior of this model are currently being conducted. A simple rotor model which includes a flexible disk and bearings with clearance has been developed and the dynamics of the model investigated. The study consists of simulation work coupled with experimental verification. The work is documented in the attached paper. A rotor model based upon the T-501 engine has been developed which includes backup bearing effects. The dynamics of this model are currently being studied with the objective of verifying the conclusions obtained from the simpler models. Parallel simulation runs are being conducted using an ANSYS based finite element model of the T-501.
Avrin, D E; Andriole, K P; Yin, L; Gould, R G; Arenson, R L
2001-03-01
A hierarchical storage management (HSM) scheme for cost-effective on-line archival of image data using lossy compression is described. This HSM scheme also provides an off-site tape backup mechanism and disaster recovery. The full-resolution image data are viewed originally for primary diagnosis, then losslessly compressed and sent off site to a tape backup archive. In addition, the original data are wavelet lossy compressed (at approximately 25:1 for computed radiography, 10:1 for computed tomography, and 5:1 for magnetic resonance) and stored on a large RAID device for maximum cost-effective, on-line storage and immediate retrieval of images for review and comparison. This HSM scheme provides a solution to 4 problems in image archiving, namely cost-effective on-line storage, disaster recovery of data, off-site tape backup for the legal record, and maximum intermediate storage and retrieval through the use of on-site lossy compression.
STS-47 crew during fire fighting exercises at JSC's Fire Training Pit
NASA Technical Reports Server (NTRS)
1992-01-01
STS-47 Endeavour, Orbiter Vehicle (OV) 105, crewmembers line up along water hoses to extinguish a blaze in JSC's Fire Training Pit during fire fighting exercises. Manning the hose in the foreground are Payload Specialist Mamoru Mohri, holding the hose nozzle, backup Payload Specialist Takao Doi, Mission Specialist (MS) Jerome Apt, and Commander Robert L. Gibson, at rear. Lined up on the second hose are Pilot Curtis L. Brown, Jr, holding the hose nozzle, followed by MS N. Jan Davis, MS and Payload Commander (PLC) Mark C. Lee, and backup Payload Specialist Stan Koszelak. A veteran firefighter monitors the effort from a position between the two hoses. In the background, backup Payload Specialist Chiaki Naito-Mukai, donning gloves, and MS Mae C. Jemison look on. The Fire Training Pit is located across from the Gilruth Center Bldg 207. Mohri, Doi, and Mukai all represent Japan's National Space Development Agency (NASDA).
2017-11-30
jsc2017e136057 - On a snowy night at Red Square Moscow, Expedition 54-55 backup crewmembers Sergey Prokopyev of the Russian Federal Space Agency (Roscosmos, left), Jeanette Epps of NASA (center) and Alexander Gerst of the European Space Agency (right) pay homage at the Kremlin Wall where Russian space icons are interred in traditional pre-launch ceremonies Nov. 30. They are backups to Anton Shkaplerov of Roscosmos, Scott Tingle of NASA and Norishige Kanai of the Japan Aerospace Exploration Agency (JAXA), who will launch from the Baikonur Cosmodrome in Kazakhstan on the Soyuz MS-07 spacecraft Dec. 17 for a five-month mission on the International Space Station...Andrey Shelepin/Gagarin Cosmonaut Training Center.
NASA Astrophysics Data System (ADS)
Kent, G. M.; Smith, K. D.; Williams, M. C.; Slater, D. E.; Plank, G.; McCarthy, M.; Rojas-Gonzalez, R.; Vernon, F.; Driscoll, N. W.; Hidley, G.
2015-12-01
The Nevada Seismological Laboratory (NSL) at UNR has recently embarked on a bold technical initiative, installing a high-speed (up to 190 Mb/sec) mountaintop-based Internet Protocol (IP) microwave network, enabling a myriad of sensor systems for Multi-Hazard Early Warning detection and response. In the Tahoe Basin, this system is known as AlertTahoe; a similar network has been deployed in north-central Nevada as part of a 5-year-long grant with BLM. The UNR network mirrors the successful HPWREN multi-hazard network run through UCSD; the UNR "Alert" program (Access to Leverage Emergency information in Real Time) has expanded on the original concept by providing a framework for early fire detection and discovery. Both systems do not rely on open-access public Internet services such as those provided by cellular service providers. Instead, they utilize private wireless communication networks to collect data 24/7 in real-time from multiple sensors throughout the system. Utilizing this restricted-access private communication platform enhances system reliability, capability, capacity and versatility for staff and its community of certified users. Both UNR and UCSD fire camera systems are presently being confederated under a common framework to provide end users (e.g., BLM, USFS, CalFire) a unified interface. Earthquake response has been both organizations' primary mission for decades; high-speed IP microwave fundamentally changes the playing field allowing for rapid early detection of wildfires, earthquakes and other natural disasters, greatly improving local and regional disaster response/recovery. For example, networked cameras can be optimally placed for wildfire detection and are significantly less vulnerable due infrastructure hardening and the ability to avoid extreme demands by the public on cellular and other public networks during a crisis. These systems also provide a backup for emergency responders to use when public access communications become overwhelmed or fail during an event. The crowd-sourced fire cameras can be viewed year round through AlertTahoe and AlertSoCal websites with on-demand time-lapse, an integrated real time lightning map, and other useful features.
Technical Report for Water Circulation Pumping System for Trihalomethanes (THMs)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bellah, W.
2015-06-08
The TSWWS was added as an active source of supply to the permit (No. 03-10-13P-003) in 2010, but has never been used due to the potential for formation of trihalomethanes (THMs) in the distribution system. THMs are formed as a by-product when chlorine is used to disinfect water for drinking. THMs are a group of chemicals generally referred to as disinfection by-products (DBPs). THMs result from the reaction of chlorine with organic matter that is present in the water. Some of the THMs are volatile and may easily vaporize into the air. This fact forms the basis of the designmore » of the system discussed in this technical report. In addition, the design is based on the results of a study that has shown success using aeration as a means to reduce TTHMs to within allowable concentration levels with turn-over times as long as ten days. The Primary Drinking Water Standards of Regulated Contaminants Maximum Contaminant Level (MCL) for TTHMs is 80 parts per billion (ppb). No other changes to the existing drinking water distribution system and chlorination operations are anticipated before switching to the TSWWS as the primary drinking water source. The two groundwater wells (Wells 20 and 18) which are currently the primary and backup water sources for the system would be maintained for use as backup supply. In the future, one of the wells may be removed from the system. A permit amendment would be filed at that time if this modification was deemed appropriate.« less
Electromagnetic attachment mechanism
NASA Technical Reports Server (NTRS)
Monford, Leo G., Jr. (Inventor)
1992-01-01
An electromagnetic attachment mechanism is disclosed for use as an end effector of a remote manipulator system. A pair of electromagnets, each with a U-shaped magnetic core with a pull-in coil and two holding coils, are mounted by a spring suspension system on a base plate of the mechanism housing with end pole pieces adapted to move through openings in the base plate when the attractive force of the electromagnets is exerted on a strike plate of a grapple fixture affixed to a target object. The pole pieces are spaced by an air gap from the strike plate when the mechanism first contacts the grapple fixture. An individual control circuit and power source is provided for the pull-in coil and one holding coil of each electromagnet. A back-up control circuit connected to the two power sources and a third power source is provided for the remaining holding coils. When energized, the pull-in coils overcome the suspension system and air gap and are automatically de-energized when the pole pieces move to grapple and impose a preload force across the grapple interface. A battery backup is a redundant power source for each electromagnet in each individual control circuit and is automatically connected upon failure of the primary source. A centerline mounted camera and video monitor are used in cooperation with a target pattern on the reflective surface of the strike plate to effect targeting and alignment.
NASA Technical Reports Server (NTRS)
Bull, John; Mah, Robert; Hardy, Gordon; Sullivan, Barry; Jones, Jerry; Williams, Diane; Soukup, Paul; Winters, Jose
1997-01-01
Partial failures of aircraft primary flight control systems and structural damages to aircraft during flight have led to catastrophic accidents with subsequent loss of lives (e.g. DC-10, B-747, C-5, B-52, and others). Following the DC-10 accident at Sioux City, Iowa in 1989, the National Transportation Safety Board recommended 'Encourage research and development of backup flight control systems for newly certified wide-body airplanes that utilize an alternate source of motive power separate from that source used for the conventional control system.' This report describes the concept of a propulsion controlled aircraft (PCA), discusses pilot controls, displays, and procedures; and presents the results of a PCA piloted simulation test and evaluation of the B747-400 airplane conducted at NASA Ames Research Center in December, 1996. The purpose of the test was to develop and evaluate propulsion control throughout the full flight envelope of the B747-400 including worst case scenarios of engine failures and out of trim moments. Pilot ratings of PCA performance ranged from adequate to satisfactory. PCA performed well in unusual attitude recoveries at 35,000 ft altitude, performed well in fully coupled ILS approaches, performed well in single engine failures, and performed well at aft cg. PCA performance was primarily limited by out-of-trim moments.
[Emergency contraception with levonorgestrel].
Saraví, Fernando D
2007-01-01
Emergency contraception may avoid pregnancy after unprotected intercourse or when regular contraceptive measures fail. Levonorgestrel, a synthetic gestagen, is recommended for emergency contraception as a single 1.5-mg dose or, alternatively, two 0.75-mg doses taken 12 h apart. Its efficacy is moderate, preventing about 80% of pregnancies. Efficacy is higher the earlier after unprotected intercourse the drug is taken, but it may be administered up to 5 days post-coitum. Tolerance is similar to, or better than, those of other oral emergency contraceptives. Adverse effects include nausea, vomiting, headache, breast tenderness and transient alteration of menstrual bleeding pattern. It is not known whether levonogestrel increases the risk of ectopic pregnancy when the treatment fails. Its use as an ongoing contraceptive method is discouraged. When given before the preovulatory LH peak, levonorgestrel blocks or delays ovulation. It may also affect sperm migration in the female reproductive tract and have an effect on fertilization. Although it has been often postulated, there is no evidence for an anti-implantatory effect. Acquaintance with the method is quite variable among different societies, but it remains underutilized even where it is well known. Advance provision of the drug has been proposed as a way to promote its use. In clinical trials, advance provision did not adversely modify sexual or regular contraceptive behavior, but it did not reduce pregnancy or abortion rate either. Therefore, emergency contraception with levonorgestrel should be regarded as a backup method which is not a substitute for the continued use of more effective contraceptive methods.
SCaN Transportable Communication Platform (STCP)
NASA Technical Reports Server (NTRS)
Haddad, George; Tanger, Thomas; Pleva, David; Schoenholz, Bryan; Nam, Connor
2017-01-01
NASA Glenn Research Center required a satellite communication trailer that served dual purposes; 24/7 Emergency Communication Services (ECS) in the event of a natural or manmade disaster that disrupted conventional communications, and a Ka Band NASA TDRS capability providing a research capability for over the air evaluations/characterizations. The trailer was to be field deployable, environmentally controlled and self-contained providing local area networks (LANs) and Wide Area Networks (WAN's) with user access both wired (Ethernet) and wireless (802.11) supporting VoIP, Internet Web access and Email. The TDRSS terminal included a 200W TWT amplifier mounted on the feed boom, individual up and down converters, and custom integrated waveguide and a supporting feed system. Other features such as a mast, generator, electrical, lighting, surveillance, and storage capabilities were also required. The Trailer was developed and demonstrated these original requested capabilities. New Requirements are defined and the trailer is now being evolved and upgraded to be a backup for the Near- Earth Network (NEN) Stations at KSC that will support the launch phase of EM-1. This paper presents the current and future capabilities of the trailer and additional options that will make it a valuable deployable asset to support remote operations from any launch from location.
Re-Educating Jet-Engine-Researchers to Stay Relevant
NASA Astrophysics Data System (ADS)
Gal-Or, Benjamin
2016-06-01
To stay relevantly supported, jet-engine researchers, designers and operators should follow changing uses of small and large jet engines, especially those anticipated to be used by/in the next generation, JET-ENGINE-STEERED ("JES") fleets of jet drones but fewer, JES-Stealth-Fighter/Strike Aircraft. In addition, some diminishing returns from isolated, non-integrating, jet-engine component studies, vs. relevant, supersonic, shock waves control in fluidic-JES-side-effects on compressor stall dynamics within Integrated Propulsion Flight Control ("IPFC"), and/or mechanical JES, constitute key relevant methods that currently move to China, India, South Korea and Japan. The central roles of the jet engine as primary or backup flight controller also constitute key relevant issues, especially under post stall conditions involving induced engine-stress while participating in crash prevention or minimal path-time maneuvers to target. And when proper instructors are absent, self-study of the JES-STVS REVOLUTION is an updating must, where STVS stands for wing-engine-airframe-integrated, embedded stealthy-jet-engine-inlets, restructured engines inside Stealth, Tailless, canard-less, Thrust Vectoring IFPC Systems. Anti-terror and Airliners Super-Flight-Safety are anticipated to overcome US legislation red-tape that obstructs JES-add-on-emergency-kits-use.
NASA Astrophysics Data System (ADS)
Li, Ze; Zhang, Min; Wang, Danshi; Cui, Yue
2017-09-01
We propose a flexible and reconfigurable wavelength-division multiplexing (WDM) multicast scheme supporting downstream emergency multicast communication for WDM optical access network (WDM-OAN) via a multicast module (MM) based on four-wave mixing (FWM) in a semiconductor optical amplifier. It serves as an emergency measure to dispose of the burst, large bandwidth, and real-time multicast service with fast service provisioning and high resource efficiency. It also plays the role of physical backup in cases of big data migration or network disaster caused by invalid lasers or modulator failures. It provides convenient and reliable multicast service and emergency protection for WDM-OAN without modifying WDM-OAN structure. The strategies of an MM setting at the optical line terminal and remote node are discussed to apply this scheme to passive optical networks and active optical networks, respectively. Utilizing the proposed scheme, we demonstrate a proof-of-concept experiment in which one-to-six/eight 10-Gbps nonreturn-to-zero-differential phase-shift keying WDM multicasts in both strategies are successfully transmitted over single-mode fiber of 20.2 km. One-to-many reconfigurable WDM multicasts dealing with higher data rate and other modulation formats of multicast service are possible through the proposed scheme. It can be applied to different WDM access technologies, e.g., time-wavelength-division multiplexing-OAN and coherent WDM-OAN, and upgraded smoothly.
A survey of light-scattering techniques used in the remote monitoring of atmospheric aerosols
NASA Technical Reports Server (NTRS)
Deirmendjian, D.
1980-01-01
A critical survey of the literature on the use of light-scattering mechanisms in the remote monitoring of atmospheric aerosols, their geographical and spatial distribution, and temporal variations was undertaken to aid in the choice of future operational systems, both ground based and air or space borne. An evaluation, mainly qualitative and subjective, of various techniques and systems is carried out. No single system is found to be adequate for operational purposes. A combination of earth surface and space-borne systems based mainly on passive techniques involving solar radiation with active (lidar) systems to provide auxiliary or backup information is tentatively recommended.
Architecture and evolution of Goddard Space Flight Center Distributed Active Archive Center
NASA Technical Reports Server (NTRS)
Bedet, Jean-Jacques; Bodden, Lee; Rosen, Wayne; Sherman, Mark; Pease, Phil
1994-01-01
The Goddard Space Flight Center (GSFC) Distributed Active Archive Center (DAAC) has been developed to enhance Earth Science research by improved access to remote sensor earth science data. Building and operating an archive, even one of a moderate size (a few Terabytes), is a challenging task. One of the critical components of this system is Unitree, the Hierarchical File Storage Management System. Unitree, selected two years ago as the best available solution, requires constant system administrative support. It is not always suitable as an archive and distribution data center, and has moderate performance. The Data Archive and Distribution System (DADS) software developed to monitor, manage, and automate the ingestion, archive, and distribution functions turned out to be more challenging than anticipated. Having the software and tools is not sufficient to succeed. Human interaction within the system must be fully understood to improve efficiency to improve efficiency and ensure that the right tools are developed. One of the lessons learned is that the operability, reliability, and performance aspects should be thoroughly addressed in the initial design. However, the GSFC DAAC has demonstrated that it is capable of distributing over 40 GB per day. A backup system to archive a second copy of all data ingested is under development. This backup system will be used not only for disaster recovery but will also replace the main archive when it is unavailable during maintenance or hardware replacement. The GSFC DAAC has put a strong emphasis on quality at all level of its organization. A Quality team has also been formed to identify quality issues and to propose improvements. The DAAC has conducted numerous tests to benchmark the performance of the system. These tests proved to be extremely useful in identifying bottlenecks and deficiencies in operational procedures.
Two dimensional nanomaterials for flexible supercapacitors.
Peng, Xu; Peng, Lele; Wu, Changzheng; Xie, Yi
2014-05-21
Flexible supercapacitors, as one of most promising emerging energy storage devices, are of great interest owing to their high power density with great mechanical compliance, making them very suitable as power back-ups for future stretchable electronics. Two-dimensional (2D) nanomaterials, including the quasi-2D graphene and inorganic graphene-like materials (IGMs), have been greatly explored to providing huge potential for the development of flexible supercapacitors with higher electrochemical performance. This review article is devoted to recent progresses in engineering 2D nanomaterials for flexible supercapacitors, which survey the evolution of electrode materials, recent developments in 2D nanomaterials and their hybrid nanostructures with regulated electrical properties, and the new planar configurations of flexible supercapacitors. Furthermore, a brief discussion on future directions, challenges and opportunities in this fascinating area is also provided.
Economical ground data delivery
NASA Technical Reports Server (NTRS)
Markley, Richard W.; Byrne, Russell H.; Bromberg, Daniel E.
1994-01-01
Data delivery in the Deep Space Network (DSN) involves transmission of a small amount of constant, high-priority traffic and a large amount of bursty, low priority data. The bursty traffic may be initially buffered and then metered back slowly as bandwidth becomes available. Today both types of data are transmitted over dedicated leased circuits. The authors investigated the potential of saving money by designing a hybrid communications architecture that uses leased circuits for high-priority network communications and dial-up circuits for low-priority traffic. Such an architecture may significantly reduce costs and provide an emergency backup. The architecture presented here may also be applied to any ground station-to-customer network within the range of a common carrier. The authors compare estimated costs for various scenarios and suggest security safeguards that should be considered.
STS 51-L crewmembers briefed during training session
NASA Technical Reports Server (NTRS)
1986-01-01
Five members of the STS 51-L crew and a backup crewmember are briefed during a training session in JSC's Shuttle mockup and integration laboratory. From left to right are Astronauts Ellison S. Onizuka, mission specialist; Ronald E. McNair, mission specialist; Gregory Jarvis, Hughes payload specialist; Judith A. Resnik, mission specialist; Sharon Christa McAuliffe, citizen observer/payload specialist representing the Teacher in Space project. Barbara R. Morgan, backup to McAuliffe, is in the right foreground.
2017-12-06
jsc2017e136942 - In the town of Baikonur, Kazakhstan, Expedition 54-55 backup crewmembers Jeanette Epps of NASA, Sergey Prokopyev of the Russian Federal Space Agency (Roscosmos) and Alexander Gerst of the European Space Agency lay flowers Dec. 6 at the sta
2017-12-06
jsc2017e136944 - In the town of Baikonur, Kazakhstan, Expedition 54-55 backup crewmembers Jeanette Epps of NASA, Sergey Prokopyev of the Russian Federal Space Agency (Roscosmos) and Alexander Gerst of the European Space Agency lay flowers Dec. 6 at the sta
1992-10-01
8 6 Summary Specs--Backup/Peak Shaving Mission Scenarios ..... 10 7 Boil-Off Replenishment (1 2-hr missions...11 8 Hybrid Oxygen Component Sizing ................................. 23 9 Mass Fraction Concentration of Condensibles..................... 25 10 ...lOIb 4" 11" 75% 18 B. 100 watt $350,000 20 wks 10 lb 100 C. 370 watt $500,000 24 wks 10 lb 370 Sulzer Bros. Turboexpander TGL-22-11/B2 $80,000 8 mos 90
Enhanced softgoods structures for spacesuit micrometeoroid/debris protective systems
NASA Technical Reports Server (NTRS)
Remington, Brian; Cadogan, David; Kosmo, Joseph
1992-01-01
A lightweight, flexible thermal micrometeoroid garment (TMG) design for enhanced space suit micrometeoroid/debris (M/D) protection is described. It will consist of an outer layer comprised of orthofabric, multilayers of aluminized Mylar, and a layer of silicone rubber loaded with micron sized particles of tungsten. The shield layers would fragment and/or vaporize the M/D projectile while the backup sheet would stop the resultant debris cloud.
Integration and Validation of Avian Radars (IVAR)
2011-07-01
IVAR study locations. ‘X’ indicates the specified type of demonstration was conducted at that location; ‘B’ indicates a potential Back-up locations... nation two radar with parabolic dishes tilted nsor (AR-1; specifically The initial deployment of avian radar systems at a civil airport was completed...ARTI. 45 Table 4-1. Summary of the IVAR study locations. ‘X’ indicates the specified type of demonstration was conducted at that
Restoring Redundancy to the MAP Propulsion System
NASA Technical Reports Server (NTRS)
ODonnell, James R., Jr.; Davis, Gary T.; Ward, David K.; Bauer, F. (Technical Monitor)
2002-01-01
The Microwave Anisotropy Probe is a follow-on to the Differential Microwave Radiometer instrument on the Cosmic Background Explorer. Sixteen months before launch, it was discovered that from the time of the critical design review, configuration changes had resulted in a significant migration of the spacecraft's center of mass. As a result, the spacecraft no longer had a viable backup control mode in the event of a failure of the negative pitch axis thruster. Potential solutions to this problem were identified, such as adding thruster plume shields to redirect thruster torque, adding mass to, or removing it from, the spacecraft, adding an additional thruster, moving thrusters, bending thrusters (either nozzles or propellant tubing), or accepting the loss of redundancy for the thruster. The impacts of each solution, including effects on the mass, cost, and fuel budgets, as well as schedule, were considered, and it was decided to bend the thruster propellant tubing of the two roll control thrusters, allowing that pair to be used for back-up control in the negative pitch axis. This paper discusses the problem and the potential solutions, and documents the hardware and software changes that needed to be made to implement the chosen solution. Flight data is presented to show the propulsion system on-orbit performance.
Onono, M A; Carraher, N; Cohen, R C; Bukusi, E A; Turan, J M
2011-09-01
To describe the development, cost effectiveness and implementation of a PDA based electronic system to collect, verify and manage data from a multi-site study on HIV/AIDS stigma and pregnancy in a rural, resource-poor area. We worked within a large prevention of mother-to-child-transmission (PMTCT) program in nine rural health facilities to implement a PDA-based data collection system and to study the feasibility of its use in a multisite HIV research study in rural Kenya. The PDAs were programmed for collecting screening and eligibility data, and responses to structured interviews on HIV/AIDS stigma and violence in three local languages. Between November 2007 and December 2008, nine PDAs were used by Clinic and Community Health Assistants to enrol 1,270 participants on to the PMTCT program. Successes included: capacity-building of interviewers, low cost of implementation, quick turnaround time of data entry with good data quality, and convenience. Our study demonstrated the feasibility of utilizing PDAs for data collection in a multi-site observational study on HIV/AIDS stigma conducted in remote rural health facilities in Kenya. However, appropriate and frequent data backup protocols need to be established and paper forms are still needed as backup tools in resource-poor settings.
Failure probability analysis of optical grid
NASA Astrophysics Data System (ADS)
Zhong, Yaoquan; Guo, Wei; Sun, Weiqiang; Jin, Yaohui; Hu, Weisheng
2008-11-01
Optical grid, the integrated computing environment based on optical network, is expected to be an efficient infrastructure to support advanced data-intensive grid applications. In optical grid, the faults of both computational and network resources are inevitable due to the large scale and high complexity of the system. With the optical network based distributed computing systems extensive applied in the processing of data, the requirement of the application failure probability have been an important indicator of the quality of application and an important aspect the operators consider. This paper will present a task-based analysis method of the application failure probability in optical grid. Then the failure probability of the entire application can be quantified, and the performance of reducing application failure probability in different backup strategies can be compared, so that the different requirements of different clients can be satisfied according to the application failure probability respectively. In optical grid, when the application based DAG (directed acyclic graph) is executed in different backup strategies, the application failure probability and the application complete time is different. This paper will propose new multi-objective differentiated services algorithm (MDSA). New application scheduling algorithm can guarantee the requirement of the failure probability and improve the network resource utilization, realize a compromise between the network operator and the application submission. Then differentiated services can be achieved in optical grid.
NASA Astrophysics Data System (ADS)
1995-03-01
This volume is the third of a 3 volume set that addresses the structural trade study plan that will identify the most suitable structural configuration for an SSTO winged vehicle capable of delivering 25,000 lbs to a 220 nm circular orbit at 51.6 deg inclination. The most suitable Reusable Hydrogen Composite Tank System (RHCTS), and Graphite Composite Tank System (GCPS) composite materials for intertank, wing and thrust structures are identified. Vehicle resizing charts, selection criteria and back-up charts, parametric costing approach and the finite element method analysis are discussed.
NASA Technical Reports Server (NTRS)
1995-01-01
This volume is the third of a 3 volume set that addresses the structural trade study plan that will identify the most suitable structural configuration for an SSTO winged vehicle capable of delivering 25,000 lbs to a 220 nm circular orbit at 51.6 deg inclination. The most suitable Reusable Hydrogen Composite Tank System (RHCTS), and Graphite Composite Tank System (GCPS) composite materials for intertank, wing and thrust structures are identified. Vehicle resizing charts, selection criteria and back-up charts, parametric costing approach and the finite element method analysis are discussed.
Digital Electronic Engine Control (DEEC) Flight Evaluation in an F-15 Airplane
NASA Technical Reports Server (NTRS)
1984-01-01
Flight evaluation in an F-15 aircraft by digital electronic engine control (DEEC) was investigated. Topics discussed include: system description, F100 engine tests, effects of inlet distortion on static pressure probe, flight tests, digital electronic engine control fault detection and accommodation flight evaluation, flight evaluation of a hydromechanical backup control, augmentor transient capability of an F100 engine, investigation of nozzle instability, real time in flight thrust calculation, and control technology for future aircraft propulsion systems. It is shown that the DEEC system is a powerful and flexible controller for the F100 engine.
DOE Office of Scientific and Technical Information (OSTI.GOV)
University of California, Berkeley; Wei, Max; Lipman, Timothy
2014-06-23
A total cost of ownership model is described for low temperature proton exchange membrane stationary fuel cell systems for combined heat and power (CHP) applications from 1-250kW and backup power applications from 1-50kW. System designs and functional specifications for these two applications were developed across the range of system power levels. Bottom-up cost estimates were made for balance of plant costs, and detailed direct cost estimates for key fuel cell stack components were derived using design-for-manufacturing-and-assembly techniques. The development of high throughput, automated processes achieving high yield are projected to reduce the cost for fuel cell stacks to the $300/kWmore » level at an annual production volume of 100 MW. Several promising combinations of building types and geographical location in the U.S. were identified for installation of fuel cell CHP systems based on the LBNL modelling tool DER CAM. Life-cycle modelling and externality assessment were done for hotels and hospitals. Reduced electricity demand charges, heating credits and carbon credits can reduce the effective cost of electricity ($/kWhe) by 26-44percent in locations such as Minneapolis, where high carbon intensity electricity from the grid is displaces by a fuel cell system operating on reformate fuel. This project extends the scope of existing cost studies to include externalities and ancillary financial benefits and thus provides a more comprehensive picture of fuel cell system benefits, consistent with a policy and incentive environment that increasingly values these ancillary benefits. The project provides a critical, new modelling capacity and should aid a broad range of policy makers in assessing the integrated costs and benefits of fuel cell systems versus other distributed generation technologies.« less
1966-09-09
This is the official NASA portrait of astronaut James Lovell. Captain Lovell was selected as an Astronaut by NASA in September 1962. He has since served as backup pilot for the Gemini 4 flight and backup Commander for the Gemini 9 flight, as well as backup Commander to Neil Armstrong for the Apollo 11 lunar landing mission. On December 4, 1965, he and Frank Borman were launched into space on the history making Gemini 7 mission. The flight lasted 330 hours and 35 minutes and included the first rendezvous of two manned maneuverable spacecraft. The Gemini 12 mission, commanded by Lovell with Pilot Edwin Aldrin, began on November 11, 1966 for a 4-day, 59-revolution flight that brought the Gemini program to a successful close. Lovell served as Command Module Pilot and Navigator on the epic six-day journey of Apollo 8, the first manned Saturn V liftoff responsible for allowing the first humans to leave the gravitational influence of Earth. He completed his fourth mission as Spacecraft Commander of the Apollo 13 flight, April 11-17, 1970, and became the first man to journey twice to the moon. The Apollo 13 mission was cut short due to a failure of the Service Module cryogenic oxygen system. Aborting the lunar course, Lovell and fellow crewmen, John L. Swigert and Fred W. Haise, working closely with Houston ground controllers, converted their lunar module, Aquarius, into an effective lifeboat that got them safely back to Earth. Captain Lovell held the record for time in space with a total of 715 hours and 5 minutes until surpassed by the Skylab flights. On March 1, 1973, Captain Lovell retired from the Navy and the Space Program.
Computers Take Flight: A History of NASA's Pioneering Digital Fly-By-Wire Project
NASA Technical Reports Server (NTRS)
Tomayko, James E.
2000-01-01
An overview of the NASA F-8 Fly-by Wire project is presented. The project made two significant contributions to the new technology: (1) a solid design base of techniques that work and those that do not, and (2) credible evidence of good flying qualities and the ability of such a system to tolerate real faults and to continue operation without degradation. In 1972 the F-8C aircraft used in the program became he first digital fly-by-wire aircraft to operate without a mechanical backup system.
Shiba, Naoto; Matsuse, Hiroo; Nago, Takeshi; Masayuki, Omoto; Kawaguchi, Takumi; Tagawa, Yoshihiko
2012-12-01
We have developed a "hybrid training system" (HTS) that is designed to maintain the musculoskeletal system of astronauts by using an electrically stimulated antagonist to resist the volitional contraction of agonist muscles in weightlessness. In other words, electrical stimulation generates a resistive force instead of gravity. HTS will become a useful back-up for the standard training device in the International Space Station, or a useful training device in the small space ship for the exploration of the Moon and Mars.
Isolation contactor state control system
Bissontz, Jay E.
2017-05-16
A controller area network (CAN) installed on a hybrid electric vehicle provides one node with control of high voltage power distribution system isolation contactors and the capacity to energize a secondary electro-mechanical relay device. The output of the secondary relay provides a redundant and persistent backup signal to the output of the node. The secondary relay is relatively immune to CAN message traffic interruptions and, as a result, the high voltage isolation contactor(s) are less likely to transition open in the event that the intelligent output driver should fail.
F-15 digital electronic engine control system description
NASA Technical Reports Server (NTRS)
Myers, L. P.
1984-01-01
A digital electronic engine control (DEEC) was developed for use on the F100-PW-100 turbofan engine. This control system has full authority control, capable of moving all the controlled variables over their full ranges. The digital computational electronics and fault detection and accomodation logic maintains safe engine operation. A hydromechanical backup control (BUC) is an integral part of the fuel metering unit and provides gas generator control at a reduced performance level in the event of an electronics failure. The DEEC's features, hardware, and major logic diagrams are described.
2017-12-06
jsc2017e136939 - At the Cosmonaut Hotel crew quarters in Baikonur, Kazakhstan, the Expedition 54-55 backup crewmembers take a stroll down the Walk of Cosmonauts Dec. 6 to lay flowers in traditional pre-launch ceremonies. From left to right are Jeanette Epp
2018-05-14
jsc2018e048512 - Expedition 56 backup crewmember Anne McClain of NASA poses for pictures in the Kremlin gardens in Moscow May 14 as part of traditional pre-launch activities. McClain is serving as a backup to the prime crew, Serena Aunon-Chancellor of NASA, Sergey Prokopyev of Roscosmos and Alexander Gerst of the European Space Agency, who will launch June 6 from the Baikonur Cosmodrome in Kazakhstan on the Soyuz MS-09 spacecraft for a six month mission on the International Space Station...NASA/Elizabeth Weissinger.
2014-12-05
NASA's Orion spacecraft floats in the Pacific Ocean after splashdown from its first flight test in Earth orbit. In the background is the USNS Salvor. This U.S. Navy salvage ship was there as a backup in case it was needed. NASA, the U.S. Navy and Lockheed Martin are coordinating efforts to recover Orion and secure the spacecraft in the well deck of the USS Anchorage. Orion completed a two-orbit, four-and-a-half hour mission, to test systems critical to crew safety, including the launch abort system, the heat shield and the parachute system. The Ground Systems Development and Operations Program is leading the recovery efforts.
NOAA's Van-Based Mobile Atmospheric Emissions Measurement Laboratory
NASA Astrophysics Data System (ADS)
Dube, W. P.; Peischl, J.; Neuman, J. A.; Eilerman, S. J.; Holloway, M.; Roberts, O.; Aikin, K. C.; Ryerson, T. B.
2015-12-01
The Chemical Science Division (CSD) mobile atmospheric emissions measurement laboratory is the second and latest of two mobile measurement vans outfitted for atmospheric sampling by the NOAA Earth System Research Laboratory. In this presentation we will describe the modifications made to this vehicle to provide a versatile and relatively inexpensive instrument platform including: the 2 kW 120 volt instrument power system; battery back-up system; data acquisition system; real-time display; meteorological, directional, and position sensor package; and the typical atmospheric emissions instrument package. The van conversion uses commercially available, off-the-shelf components from the marine and RV industries, thus keeping the costs quite modest.
Schuchert, Andreas; Frese, Jens; Stammwitz, Ekkehard; Novák, Miroslav; Schleich, Arthur; Wagner, Stefan M; Meinertz, Thomas
2002-06-01
It is generally acknowledged that pacemaker output must be adjusted with a 100% voltage safety margin above the pacing threshold to avoid ineffective pacing, especially in patients dependent on pacemakers. The aim of this prospective crossover study was to assess the beat-to-beat safety of low outputs in patients who are dependent on a pacemaker between 2 follow-up examinations. The study included 12 patients who had received a DDD pacemaker with an automatic beat-to-beat capture verification function. The ventricular output at 0.4 milliseconds pulse duration was programmed independently of the actual pacing threshold in a crossover randomization to 1.0 V, 1.5 V, and 2.5 V for 6 weeks each. At each follow-up, the diagnostic counters were interrogated and the pacing threshold at 0.4 milliseconds was determined in 0.1-V steps. The diagnostic pacemaker counters depict the frequency of back-up pulses delivered because of a loss of capture. During the randomization to 1.0-V output, we evaluated whether the adjustment of the output under consideration of the >100% voltage safety margin reduced the frequency of back-up pulses. Pacing thresholds at the randomization to 1.0-V, 1.5-V, and 2.5-V output were not significantly different, with 0.7 +/- 0.3 V at 2.5-V output, 0.6 +/- 0.2 V at 1.5-V output, and 0.6 +/- 0.2 V at 1.0-V output. The frequency of back-up pulses was similar at 2.5-V and 1.5-V output, 2.2% +/- 1.9% and 2.0% +/- 2.0%, respectively. The frequency of back-up pulses significantly increased at 1.0-V output to 5.8% +/- 6.4% (P <.05). Back-up pulses >5% of the time between the 2 follow-ups were observed in no patient at 2.5 V, in 1 patient at 1.5 V, and in 5 patients at 1.0 V. At the randomization to the 1.0-V output, 6 patients had pacing thresholds of 0.5 V or less, and 6 patients had pacing thresholds >0.5 V. The frequency of back-up pulses in the 2 groups was not significantly different, 6.4% +/- 8.6% and 5.7% +/- 2.6%. The frequency of back-up pulses was significantly higher at 1.0-V output than at 1.5-V and 2.5-V output. This also applied to patients with pacing thresholds of < or =0.5 V. Fixed low outputs seem not to be absolutely safe between 2 follow-ups in patients who are dependent on a pacemaker, even when the output has a 100% voltage safety margin above the pacing threshold. When patients with pacemakers programmed to a low ventricular output have symptoms of ineffective pacing, an intermittent increase of the pacing threshold should be carefully ruled out.
Shaaban, Omar M; Hassen, Shaimaa G; Nour, Sanna A; Kames, Mervat A; Yones, Entsar M
2013-03-01
The use of breastfeeding as a method of birth spacing occasionally ends in "unplanned pregnancy." This is due to unexpected expiration of one or more of the lactation amenorrhea method (LAM) prerequisites. The current study tests a new concept that the in-advance provision of single packet of progestogen emergency contraception (EC) pills during the postpartum LAM counseling may decrease the incidence of unplanned pregnancy during breastfeeding. This was a registered two-armed randomized controlled trial (NCT 01111929). Women intending to breastfeed and to postpone pregnancy for 1 year or more were approached. They received adequate postpartum contraceptive counseling. Women intending to use LAM were randomly assigned to one of two groups. The LAM-only group received the proper LAM counseling and did not receive counseling about EC. The LAM-EC group received counseling for both LAM and EC with in-advance provision of one packet of EC pills. They were advised to use these pills if one of the prerequisites of LAM expires and sexual relation has occurred before the initiation of another regular contraceptive protection. All the participants were advised that they need to use another regular method upon expiration of any of the LAM prerequisites. Eligible women were 1158 parturients randomized into two equal groups. Forty-four percent of the women provided with EC used them. Significantly more women in the LAM-EC group initiated regular contraception within or shortly after the first 6 months postpartum when compared with those in the LAM-only group (30.5% vs. 7.3%, respectively; p=.0004). Pregnancy occurred in 5% of the LAM-only group as compared with 0.8% in the LAM-EC group (p=.005). Minimal side effects were reported after EC use. In-advance provision of EC pills can increase the rate of initiation of regular contraception once one or more of the prerequisites of LAM expire. Consequently, the use of EC pills as a temporary backup of LAM can decrease the incidence of unplanned pregnancy during breastfeeding. The use of progestogen EC pill during lactation is safe and tolerable. Copyright © 2013 Elsevier Inc. All rights reserved.
Nursing Home Self-assessment of Implementation of Emergency Preparedness Standards.
Lane, Sandi J; McGrady, Elizabeth
2016-08-01
Introduction Disasters often overwhelm a community's capacity to respond and recover, creating a gap between the needs of the community and the resources available to provide services. In the wake of multiple disasters affecting nursing homes in the last decade, increased focus has shifted to this vital component of the health care system. However, the long-term care sector has often fallen through the cracks in both planning and response. Problem Two recent reports (2006 and 2012) published by the US Department of Health and Human Services (DHHS), Office of Inspector General (OIG), elucidate the need for improvements in nursing homes' comprehensive emergency preparedness and response. The Center for Medicare and Medicaid Services (CMS) has developed an emergency preparedness checklist as a guidance tool and proposed emergency preparedness regulations. The purpose of this study was to evaluate the progress made in nursing home preparedness by determining the level of completion of the 70 tasks noted on the checklist. The study objectives were to: (1) determine the preparedness levels of nursing homes in North and South Carolina (USA), and (2) compare these findings with the 2012 OIG's report on nursing home preparedness to identify current gaps. A survey developed from the checklist of items was emailed to 418 North Carolina and 193 South Carolina nursing home administrators during 2014. One hundred seventeen were returned/"bounced back" as not received. Follow-up emails and phone calls were made to encourage participation. Sixty-three completed surveys and 32 partial surveys were received. Responses were compared to data obtained in a 2010 study to determine progress. Progress had been made in many of the overall planning and sheltering-in-place tasks, such as having contact information of local emergency managers as well as specifications for availability of potable water. Yet, gaps still persisted, especially in evacuation standards, interfacing with emergency management officials, establishing back-up evacuation sites and evacuation routes, identification of resident care items, and obtaining copies of state and local emergency planning regulations. Nursing homes have made progress in preparedness tasks, however, gaps persist. Compliance may prove challenging for some nursing homes, but closer integration with emergency management officials certainly is a step in the right direction. Further research that guides evacuation or shelter-in-place decision making is needed in light of persistent challenges in completing these tasks. Lane SJ , McGrady E . Nursing home self-assessment of implementation of emergency preparedness standards. Prehosp Disaster Med. 2016;31(4):422-431.
2005-09-01
Computer Memory Card International Association PHY Physical PLI Position Location Information PLRS Position Location Reporting System PoP Point of...it is widely acknowledged that the JTRS program will not be providing any sustentative operational capability prior to FY’09. This reality has...Figure 5, and a man-packed antenna (AS- 3448/PSQ-4). Back-up (cryptographic key) memory is maintained by a traditional 9v 24
NASA Technical Reports Server (NTRS)
Kuebert, E. J.
1977-01-01
A Laser Altimeter and Mapping Camera System was included in the Apollo Lunar Orbital Experiment Missions. The backup system, never used in the Apollo Program, is available for use in the Lidar Test Experiments on the STS Orbital Flight Tests 2 and 4. Studies were performed to assess the problem associated with installation and operation of the Mapping Camera System in the STS. They were conducted on the photographic capabilities of the Mapping Camera System, its mechanical and electrical interface with the STS, documentation, operation and survivability in the expected environments, ground support equipment, test and field support.
Independent Orbiter Assessment (IOA): Assessment of the backup flight system FMEA/CIL
NASA Technical Reports Server (NTRS)
Prust, E. E.; Ewell, J. J., Jr.; Hinsdale, L. W.
1988-01-01
The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA effort first completed an analysis of the Backup Flight System (BFS) hardware, generating draft failure modes and Potential Critical Items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. The IOA results were then compared to the proposed NASA Post 51-L FMEA/CIL baseline. A resolution of each discrepancy from the comparison is provided through additional analysis as required. This report documents the results of that comparison for the Orbiter BFS hardware. The IOA product for the BFS analysis consisted of 29 failure mode worksheets that resulted in 21 Potential Critical Items (PCI) being identified. This product was originally compared with the proposed NASA BFS baseline and subsequently compared with the applicable Data Processing System (DPS), Electrical Power Distribution and Control (EPD and C), and Displays and Controls NASA CIL items. The comparisons determined if there were any results which had been found by the IOA but were not in the NASA baseline. The original assessment determined there were numerous failure modes and potential critical items in the IOA analysis that were not contained in the NASA BFS baseline. Conversely, the NASA baseline contained three FMEAs (IMU, ADTA, and Air Data Probe) for CIL items that were not identified in the IOA product.