Sample records for emergency spray programs

  1. Efficacy of Aedes aegypti control by indoor Ultra Low Volume (ULV) insecticide spraying in Iquitos, Peru

    PubMed Central

    Okamoto, Kenichi W.; Astete, Helvio; Vasquez, Gissella M.; Del Aguila, Clara; Pinedo, Raul; Cardenas, Roldan; Pacheco, Carlos; Chalco, Enrique; Rodriguez-Ferruci, Hugo; Scott, Thomas W.; Lloyd, Alun L.; Gould, Fred

    2018-01-01

    Background Aedes aegypti is a primary vector of dengue, chikungunya, Zika, and urban yellow fever viruses. Indoor, ultra low volume (ULV) space spraying with pyrethroid insecticides is the main approach used for Ae. aegypti emergency control in many countries. Given the widespread use of this method, the lack of large-scale experiments or detailed evaluations of municipal spray programs is problematic. Methodology/Principal findings Two experimental evaluations of non-residual, indoor ULV pyrethroid spraying were conducted in Iquitos, Peru. In each, a central sprayed sector was surrounded by an unsprayed buffer sector. In 2013, spray and buffer sectors included 398 and 765 houses, respectively. Spraying reduced the mean number of adults captured per house by ~83 percent relative to the pre-spray baseline survey. In the 2014 experiment, sprayed and buffer sectors included 1,117 and 1,049 houses, respectively. Here, the sprayed sector’s number of adults per house was reduced ~64 percent relative to baseline. Parity surveys in the sprayed sector during the 2014 spray period indicated an increase in the proportion of very young females. We also evaluated impacts of a 2014 citywide spray program by the local Ministry of Health, which reduced adult populations by ~60 percent. In all cases, adult densities returned to near-baseline levels within one month. Conclusions/Significance Our results demonstrate that densities of adult Ae. aegypti can be reduced by experimental and municipal spraying programs. The finding that adult densities return to approximately pre-spray densities in less than a month is similar to results from previous, smaller scale experiments. Our results demonstrate that ULV spraying is best viewed as having a short-term entomological effect. The epidemiological impact of ULV spraying will need evaluation in future trials that measure capacity of insecticide spraying to reduce human infection or disease. PMID:29624581

  2. Development testing of large volume water sprays for warm fog dispersal

    NASA Technical Reports Server (NTRS)

    Keller, V. W.; Anderson, B. J.; Burns, R. A.; Lala, G. G.; Meyer, M. B.; Beard, K. V.

    1986-01-01

    A new brute-force method of warm fog dispersal is described. The method uses large volume recycled water sprays to create curtains of falling drops through which the fog is processed by the ambient wind and spray induced air flow. Fog droplets are removed by coalescence/rainout. The efficiency of the technique depends upon the drop size spectra in the spray, the height to which the spray can be projected, the efficiency with which fog laden air is processed through the curtain of spray, and the rate at which new fog may be formed due to temperature differences between the air and spray water. Results of a field test program, implemented to develop the data base necessary to assess the proposed method, are presented. Analytical calculations based upon the field test results indicate that this proposed method of warm fog dispersal is feasible. Even more convincingly, the technique was successfully demonstrated in the one natural fog event which occurred during the test program. Energy requirements for this technique are an order of magnitude less than those to operate a thermokinetic system. An important side benefit is the considerable emergency fire extinguishing capability it provides along the runway.

  3. Pesticide Spraying for West Nile Virus Control and Emergency Department Asthma Visits in New York City, 2000

    PubMed Central

    Karpati, Adam M.; Perrin, Mary C.; Matte, Tom; Leighton, Jessica; Schwartz, Joel; Barr, R. Graham

    2004-01-01

    Pyrethroid pesticides were applied via ground spraying to residential neighborhoods in New York City during July–September 2000 to control mosquito vectors of West Nile virus (WNV). Case reports link pyrethroid exposure to asthma exacerbations, but population-level effects on asthma from large-scale mosquito control programs have not been assessed. We conducted this analysis to determine whether widespread urban pyrethroid pesticide use was associated with increased rates of emergency department (ED) visits for asthma. We recorded the dates and locations of pyrethroid spraying during the 2000 WNV season in New York City and tabulated all ED visits for asthma to public hospitals from October 1999 through November 2000 by date and ZIP code of patients’ residences. The association between pesticide application and asthma-related emergency visits was evaluated across date and ZIP code, adjusting for season, day of week, and daily temperature, precipitation, particulate, and ozone levels. There were 62,827 ED visits for asthma during the 14-month study period, across 162 ZIP codes. The number of asthma visits was similar in the 3-day periods before and after spraying (510 vs. 501, p = 0.78). In multivariate analyses, daily rates of asthma visits were not associated with pesticide spraying (rate ratio = 0.92; 95% confidence interval, 0.80–1.07). Secondary analyses among children and for chronic obstructive pulmonary disease yielded similar null results. This analysis shows that spraying pyrethroids for WNV control in New York City was not followed by population-level increases in public hospital ED visit rates for asthma. PMID:15289164

  4. 78 FR 20832 - Energy Conservation Program for Consumer Products and Certain Commercial and Industrial Equipment...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-08

    ... ``leak significantly'' to mean the visible emergence of water from parts of the showerhead other than the... Procedures for Showerheads, Faucets, Water Closets, Urinals, and Commercial Prerinse Spray Valves AGENCY... notice of proposed rulemaking related to DOE test procedures for showerheads, faucets, water closets...

  5. [Ethyl chloride aerosol spray for local anesthesia before arterial puncture: randomized placebo-controlled trial].

    PubMed

    Ballesteros-Peña, Sendoa; Fernández-Aedo, Irrintzi; Vallejo-De la Hoz, Gorka

    2017-06-01

    To compare the efficacy of an ethyl chloride aerosol spray to a placebo spray applied in the emergency department to the skin to reduce pain from arterial puncture for blood gas analysis. Single-blind, randomized placebo-controlled trial in an emergency department of Hospital de Basurto in Bilbao, Spain. We included 126 patients for whom arterial blood gas analysis had been ordered. They were randomly assigned to receive application of the experimental ethyl chloride spray (n=66) or a placebo aerosol spray of a solution of alcohol in water (n=60). The assigned spray was applied just before arterial puncture. The main outcome variable was pain intensity reported on an 11-point numeric rating scale. The median (interquartile range) pain level was 2 (1-5) in the experimental arm and 2 (1-4.5) in the placebo arm (P=.72). Topical application of an ethyl chloride spray did not reduce pain caused by arterial puncture.

  6. Sea Spray and Icing in the Emerging Open Water of the Arctic Ocean

    DTIC Science & Technology

    2015-06-12

    concentrations of wind-generated sea spray and the resulting spray icing on offshore structures, such as wind turbines and exploration, drilling , and...We anticipate that structures placed in shallow water—wind turbines, drilling rigs, or man-made production islands, for instance—will, therefore...and the severity of sea spray icing on fixed offshore structures. We will use existing information on the relationship of the spray concentration

  7. DepositScan, a Scanning Program to Measure Spray Deposition Distributions

    USDA-ARS?s Scientific Manuscript database

    DepositScan, a scanning program was developed to quickly measure spray deposit distributions on water sensitive papers or Kromekote cards which are widely used for determinations of pesticide spray deposition quality on target areas. The program is installed in a portable computer and works with a ...

  8. An overview of spray drift reduction testing of spray nozzles

    USDA-ARS?s Scientific Manuscript database

    The importance of the development and testing of drift reduction technologies (DRTs) is increasing. Common spray drift reduction technologies include spray nozzles and spray adjuvants. Following draft procedures developed for a DRT program, three spray nozzles were tested under high air speed cond...

  9. Sea Spray and Icing in the Emerging Open Water of the Arctic Ocean

    DTIC Science & Technology

    2013-06-17

    can create copious amounts of sea spray. We anticipate that structures placed in shallow water— wind turbines or drilling rigs, for instance— will...anticipate that structures placed in shallow water— wind turbines or drilling rigs, for instance—will, therefore, experience more episodes of freezing...concentrations of wind -generated sea spray and the resulting spray icing on offshore structures, such as wind turbines and exploration, drilling, and production

  10. Program Models A Laser Beam Focused In An Aerosol Spray

    NASA Technical Reports Server (NTRS)

    Barton, J. P.

    1996-01-01

    Monte Carlo analysis performed on packets of light. Program for Analysis of Laser Beam Focused Within Aerosol Spray (FLSPRY) developed for theoretical analysis of propagation of laser pulse optically focused within aerosol spray. Applied for example, to analyze laser ignition arrangement in which focused laser pulse used to ignite liquid aerosol fuel spray. Scattering and absorption of laser light by individual aerosol droplets evaluated by use of electromagnetic Lorenz-Mie theory. Written in FORTRAN 77 for both UNIX-based computers and DEC VAX-series computers. VAX version of program (LEW-16051). UNIX version (LEW-16065).

  11. Effectiveness of Large-Scale Chagas Disease Vector Control Program in Nicaragua by Residual Insecticide Spraying Against Triatoma dimidiata.

    PubMed

    Yoshioka, Kota; Nakamura, Jiro; Pérez, Byron; Tercero, Doribel; Pérez, Lenin; Tabaru, Yuichiro

    2015-12-01

    Chagas disease is one of the most serious health problems in Latin America. Because the disease is transmitted mainly by triatomine vectors, a three-phase vector control strategy was used to reduce its vector-borne transmission. In Nicaragua, we implemented an indoor insecticide spraying program in five northern departments to reduce house infestation by Triatoma dimidiata. The spraying program was performed in two rounds. After each round, we conducted entomological evaluation to compare the vector infestation level before and after spraying. A total of 66,200 and 44,683 houses were sprayed in the first and second spraying rounds, respectively. The entomological evaluation showed that the proportion of houses infested by T. dimidiata was reduced from 17.0% to 3.0% after the first spraying, which was statistically significant (P < 0.0001). However, the second spraying round did not demonstrate clear effectiveness. Space-time analysis revealed that reinfestation of T. dimidiata is more likely to occur in clusters where the pre-spray infestation level is high. Here we discuss how large-scale insecticide spraying is neither effective nor affordable when T. dimidiata is widely distributed at low infestation levels. Further challenges involve research on T. dimidiata reinfestation, diversification of vector control strategies, and implementation of sustainable vector surveillance. © The American Society of Tropical Medicine and Hygiene.

  12. Bear Spray Safety Program

    USGS Publications Warehouse

    Blome, C.D.; Kuzniar, R.L.

    2009-01-01

    A bear spray safety program for the U.S. Geological Survey (USGS) was officially initiated by the Firearms Safety Committee to address accident prevention and to promote personnel training in bear spray and its transportation, storage, and use for defense against wild animals. Used as part of a system including firearms, or used alone for those who choose not to carry a firearm, bear spray is recognized as an effective tool that can prevent injury in a wild animal attack.

  13. Developing a dispersant spraying capability

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gill, S.D.

    1979-01-01

    In developing a national dispersant spraying capability, the Canadian Coast Guard (CCG) has undertaken a modification program to enable the conventional offshore spraying gear to be mounted on almost any vessel of convenience. Smaller, more versatile inshore spraying vessels and pumps have been designed and built. With the popularization of concentrated dispersants, the inshore pumping equipment can be used aboard hovercraft for special application situations. A program of acquiring mobile dispersant storage tanks has been undertaken with auxiliary equipment that will facilitate the shipment of dispersants in bulk by air freight. Work also has commenced on extending the dispersant applicationmore » program to include the CCG fleet of helicopters.« less

  14. Spray dried plasma as an alternative to antibiotics in piglet feeds, mode of action and biosafety.

    PubMed

    Pérez-Bosque, Anna; Polo, Javier; Torrallardona, David

    2016-01-01

    The use of growth promoting and therapeutic antibiotics in piglet feed has been a concerning subject over the last few decades because of the risk of generating antimicrobial resistance that could be transferred to humans. As a result, many products have been proposed as potential alternatives to the use of antibiotics, and among these, spray dried plasma is considered one of the most promising. However, there have been concerns about its biosafety, particularly during periods of emergence or re-emergence of swine diseases in different regions of the world, such as the recent porcine epidemic diarrhea virus outbreak in North America. The objectives of this paper are to review recent publications about the use of spray dried plasma as an alternative to antibiotics in weaned pig diets, the possible mechanisms of action of spray dried plasma, and the existing evidence related to the biosafety of spray dried animal plasma. Particular attention is given to studies in which spray dried plasma has been directly compared to antibiotics or other alternative antimicrobial products. Several studies on the possible modes of action for spray dried plasma, such as preservation of gut barrier function or modulation of the immune response, are also reviewed. Finally, the paper focuses on the review of the existing studies on the risks of disease transmission with the use of spray dried plasma from porcine origin. Overall, spray dried plasma is a promising alternative to in-feed antimicrobials for piglets, particularly during the early stages of the post-weaning phase. Additionally, there is enough evidence to support that commercial spray dried porcine plasma is a safe product for pigs.

  15. MDI Exposure for Spray-On Truck Bed Lining.

    PubMed

    Lofgren, Don J; Walley, Terry L; Peters, Phillip M; Weis, Marty L

    2003-10-01

    Worker exposure to MDI (methylenediphenyl isocyanate) in the sprayed-on truck bed lining industry was assessed by examining Washington State OSHA inspection files and industrial insurance records. The industry uses MDI to form a protective urethane coating on pick-up truck beds. The lining is applied by a worker using a handheld spray gun with application equipment at temperatures and pressures specified by the urethane supplier. Inspections with MDI sampling were initially identified by searching the agency's laboratory database and were further screened for the targeted process. Data for 13 employers was found and extracted from the inspection records. All were small companies with only 1 to 2 workers exposed to MDI; 10 of the 13 employers had started the bed lining service within the last 4 years. The process was found in truck bed lining specialty shops as well as in other truck-related businesses. Six different urethane products were used with reported MDI monomer concentrations of up to 75 percent along with varying concentrations of MDI pre-polymers and other reactants and solvents. Sampling for MDI by inspectors found 7 worksites with worker exposure in excess of the state and OSHA ceiling limit of 0.200 mg/M(3). Deficiencies in respirator programs and engineering controls for MDI were cited. A review of the industrial insurance records found a total of five MDI-related claims at 4 inspected worksites, two for new-onset asthma. It was concluded that workers in the urethane sprayed-on truck bed lining industry are at an increased risk of developing illnesses associated with isocyanate exposure. Interventions are needed to further assess the hazard as well as motivate and assist franchisers, distributors, and retailers to implement effective engineering controls and respiratory protection programs in this nationally emerging small employer industry.

  16. Reducing Pesticide Drift

    EPA Pesticide Factsheets

    Provides information about pesticide spray drift, including problems associated with drift, managing risks from drift and the voluntary Drift Reduction Technology program that seeks to reduce spray drift through improved spray equipment design.

  17. Field Test of Advanced Duct-Sealing Technologies Within the Weatherization Assistance Program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ternes, MP

    A field test of an aerosol-spray duct-sealing technology and a conventional, best-practice approach was performed in 80 homes to determine the efficacy and programmatic needs of the duct-sealing technologies as applied in the U.S. Department of Energy Weatherization Assistance Program. The field test was performed in five states: Iowa, Virginia, Washington, West Virginia, and Wyoming. The study found that, compared with the best-practice approach, the aerosol-spray technology is 50% more effective at sealing duct leaks and can potentially reduce labor time and costs for duct sealing by 70%, or almost 4 crew-hours. Further study to encourage and promote use ofmore » the aerosol-spray technology within the Weatherization Assistance Program is recommended. A pilot test of full production weatherization programs using the aerosol-spray technology is recommended to develop approaches for integrating this technology with other energy conservation measures and minimizing impacts on weatherization agency logistics. In order to allow or improve adoption of the aerosol spray technology within the Weatherization Assistance Program, issues must be addressed concerning equipment costs, use of the technology under franchise arrangements with Aeroseal, Inc. (the holders of an exclusive license to use this technology), software used to control the equipment, safety, and training. Application testing of the aerosol-spray technology in mobile homes is also recommended.« less

  18. Evaluating the treatment efficacy of Bacillus thuriengiensis Var. Kurstaki: reliability of various tools

    Treesearch

    Ghislain Rousseau

    2003-01-01

    The success of an operational or pilot insecticide spraying program against the spruce budworm (Choristoneura fumiferana Clemens) depends to a great extent on a variety of factors, and, in particular on: spraying efficacy and the meteorological conditions during and immediately following spraying. Among other things, spraying efficacy depends on:...

  19. Obtaining Thickness-Limited Electrospray Deposition for 3D Coating.

    PubMed

    Lei, Lin; Kovacevich, Dylan A; Nitzsche, Michael P; Ryu, Jihyun; Al-Marzoki, Kutaiba; Rodriguez, Gabriela; Klein, Lisa C; Jitianu, Andrei; Singer, Jonathan P

    2018-04-04

    Electrospray processing utilizes the balance of electrostatic forces and surface tension within a charged spray to produce charged microdroplets with a narrow dispersion in size. In electrospray deposition, each droplet carries a small quantity of suspended material to a target substrate. Past electrospray deposition results fall into two major categories: (1) continuous spray of films onto conducting substrates and (2) spray of isolated droplets onto insulating substrates. A crossover regime, or a self-limited spray, has only been limitedly observed in the spray of insulating materials onto conductive substrates. In such sprays, a limiting thickness emerges, where the accumulation of charge repels further spray. In this study, we examined the parametric spray of several glassy polymers to both categorize past electrospray deposition results and uncover the critical parameters for thickness-limited sprays. The key parameters for determining the limiting thickness were (1) field strength and (2) spray temperature, related to (i) the necessary repulsive field and (ii) the ability for the deposited materials to swell in the carrier solvent vapor and redistribute charge. These control mechanisms can be applied to the uniform or controllably-varied microscale coating of complex three-dimensional objects.

  20. Spray nozzle investigation for the Improved Helicopter Icing Spray System (IHISS)

    NASA Technical Reports Server (NTRS)

    Peterson, Andrew A.; Oldenburg, John R.

    1990-01-01

    A contract has been awarded by the U.S. Army to design, fabricate and test a replacement for the existing Helicopter Icing Spray System. Data are shown for extensive bench and icing tunnel test programs used to select and modify an improved spray nozzle. The IHISS, capable of deployment from any CH-47 helicopter, will include new icing spray nozzles and pneumatic pressure source, and a significantly larger water tank and spray boom. The resulting system will provide a significantly larger icing cloud with droplet characteristics closely matching natural icing conditions.

  1. Workplace safety and health programs, practices, and conditions in auto collision repair businesses.

    PubMed

    Brosseau, L M; Bejan, A; Parker, D L; Skan, M; Xi, M

    2014-01-01

    This article describes the results of a pre-intervention safety assessment conducted in 49 auto collision repair businesses and owners' commitments to specific improvements. A 92-item standardized audit tool employed interviews, record reviews, and observations to assess safety and health programs, training, and workplace conditions. Owners were asked to improve at least one-third of incorrect, deficient, or missing (not in compliance with regulations or not meeting best practice) items, of which a majority were critical or highly important for ensuring workplace safety. Two-thirds of all items were present, with the highest fraction related to electrical safety, machine safety, and lockout/tagout. One-half of shops did not have written safety programs and had not conducted recent training. Many had deficiencies in respiratory protection programs and practices. Thirteen businesses with a current or past relationship with a safety consultant had a significantly higher fraction of correct items, in particular related to safety programs, up-to-date training, paint booth and mixing room conditions, electrical safety, and respiratory protection. Owners selected an average of 58% of recommended improvements; they were most likely to select items related to employee Right-to-Know training, emergency exits, fire extinguishers, and respiratory protection. They were least likely to say they would improve written safety programs, stop routine spraying outside the booth, or provide adequate fire protection for spray areas outside the booth. These baseline results suggest that it may be possible to bring about workplace improvements using targeted assistance from occupational health and safety professionals.

  2. Spatial and temporal distribution of airborne Bacillus thuringiensis var. kurstaki during an aerial spray program for gypsy moth eradication.

    PubMed

    Teschke, K; Chow, Y; Bartlett, K; Ross, A; van Netten, C

    2001-01-01

    We measured airborne exposures to the biological insecticide Bacillus thuringiensis var. kurstaki (Btk) during an aerial spray program to eradicate gypsy moths on the west coast of Canada. We aimed to determine whether staying indoors during spraying reduced exposures, to determine the rate of temporal decay of airborne concentrations, and to determine whether drift occurred outside the spray zone. During spraying, the average culturable airborne Btk concentration measured outdoors within the spray zone was 739 colony-forming units (CFU)/m3 of air. Outdoor air concentrations decreased over time, quickly in an initial phase with a half time of 3.3 hr, and then more slowly over the following 9 days, with an overall half-time of about 2.4 days. Inside residences during spraying, average concentrations were initially 2-5 times lower than outdoors, but at 5-6 hr after spraying began, indoor concentrations exceeded those outdoors, with an average of 244 CFU/m3 vs. 77 CFU/m3 outdoors, suggesting that the initial benefits of remaining indoors during spraying may not persist as outside air moves indoors with normal daily activities. There was drift of culturable Btk throughout a 125- to 1,000-meter band outside the spray zone where measurements were made, a consequence of the fine aerosol sizes that remained airborne (count median diameters of 4.3 to 7.2 microm). Btk concentrations outside the spray zone were related to wind speed and direction, but not to distance from the spray zone.

  3. Plasma Spraying of Ceramics with Particular Difficulties in Processing

    NASA Astrophysics Data System (ADS)

    Mauer, G.; Schlegel, N.; Guignard, A.; Jarligo, M. O.; Rezanka, S.; Hospach, A.; Vaßen, R.

    2015-01-01

    Emerging new applications and growing demands of plasma-sprayed coatings initiate the development of new materials. Regarding ceramics, often complex compositions are employed to achieve advanced material properties, e.g., high thermal stability, low thermal conductivity, high electronic and ionic conductivity as well as specific thermo-mechanical properties and microstructures. Such materials however, often involve particular difficulties in processing by plasma spraying. The inhomogeneous dissociation and evaporation behavior of individual constituents can lead to changes of the chemical composition and the formation of secondary phases in the deposited coatings. Hence, undesired effects on the coating characteristics are encountered. In this work, examples of such challenging materials are investigated, namely pyrochlores applied for thermal barrier coatings as well as perovskites for gas separation membranes. In particular, new plasma spray processes like suspension plasma spraying and plasma spray-physical vapor deposition are considered. In some cases, plasma diagnostics are applied to analyze the processing conditions.

  4. NASA Astrophysics Data System (ADS)

    McHugh, K. M.; Key, J. F.

    1994-06-01

    Spray forming is a near- net- shape fabrication technology in which a spray of finely atomized liquid droplets is deposited onto a suitably shaped substrate or pattern to produce a coherent solid. The technology offers unique opportunities for simplifying materials processing, often while substantially improving product quality. Spray forming is applicable to a wide range of metals and nonmetals and offers property improvements resulting from rapid solidification (e.g., refined microstructures, extended solid solubilities, and reduced segregation). Economic benefits result from process simplification and the elimination of unit operations. Researchers at the Idaho National Engineering Laboratory (INEL) are developing spray forming technology for producing near- net- shape solids and coatings of a variety of metals, polymers, and composite materials using de Laval nozzles. This article briefly describes the atomization behavior of liquid metals in linear de Laval nozzles and illustrates the versatility of the process by summarizing results from two spray forming programs. In one program, low-carbon steel strip >0.75 mm thick was produced; in the other, polymer membranes ˜5 μm thick were spray formed.

  5. Technology Insertion for Recapitalization of Legacy Systems

    DTIC Science & Technology

    2015-09-30

    peened, and 4) an Abcite coating will be flame sprayed on the component. The ALCM program (B) has 1) evaluated data provided, 2) gathered questions...Report Technology Insertion for the Recapitalization of Legacy Systems Laser sintering, thermal spray and cold spray are additive manufacturing methods... coatings Need an experienced operator Requires a special spray booth to limit overspray and protect operator Requires primer or surface treatment

  6. A probabilistic risk assessment for deployed military personnel after the implementation of the "Leishmaniasis Control Program" at Tallil Air Base, Iraq.

    PubMed

    Schleier, Jerome J; Davis, Ryan S; Barber, Loren M; Macedo, Paula A; Peterson, Robert K D

    2009-05-01

    Leishmaniasis has been of concern to the U.S. military and has re-emerged in importance because of recent deployments to the Middle East. We conducted a retrospective probabilistic risk assessment for military personnel potentially exposed to insecticides during the "Leishmaniasis Control Plan" (LCP) undertaken in 2003 at Tallil Air Base, Iraq. We estimated acute and subchronic risks from resmethrin, malathion, piperonyl butoxide (PBO), and pyrethrins applied using a truck-mounted ultra-low-volume (ULV) sprayer and lambda-cyhalothrin, cyfluthrin, bifenthrin, chlorpyrifos, and cypermethrin used for residual sprays. We used the risk quotient (RQ) method for our risk assessment (estimated environmental exposure/toxic endpoint) and set the RQ level of concern (LOC) at 1.0. Acute RQs for truck-mounted ULV and residual sprays ranged from 0.00007 to 33.3 at the 95th percentile. Acute exposure to lambda-cyhalothrin, bifenthrin, and chlorpyrifos exceeded the RQ LOC. Subchronic RQs for truck-mounted ULV and residual sprays ranged from 0.00008 to 32.8 at the 95th percentile. Subchronic exposures to lambda-cyhalothrin and chlorpyrifos exceeded the LOC. However, estimated exposures to lambda-cyhalothrin, bifenthrin, and chlorpyrifos did not exceed their respective no observed adverse effect levels.

  7. 10 CFR 431.262 - Definitions concerning commercial prerinse spray valves.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Definitions concerning commercial prerinse spray valves. 431.262 Section 431.262 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN COMMERCIAL AND INDUSTRIAL EQUIPMENT Commercial Prerinse Spray Valves § 431.262 Definitions...

  8. Self-extinguishing behavior of kerosene spray fire in a completely enclosed compartment

    NASA Astrophysics Data System (ADS)

    Wang, Changjian; Guo, Jin; Yan, Weigang; Lu, Shouxiang

    2013-10-01

    The self-extinguishing behavior of kerosene spray fire was investigated in a completely enclosed compartment with the size of 3 m × 3 m × 3.4 m. The spray was generated by locating one BETE nozzle at the center of the bottom wall. A series of spray fire videos were obtained by changing BETE nozzle type and injecting pressure. The results show that spray fire undergoes four stages: the growth stage, the quasi-steady stage, the stretch stage and the self-extinguishing stage. Consumption of large quantities of oxygen causes spray fire to first be stretched and then quench. In this process, fire base migrates away from spray region and leads to the emergence of ghosting fire. Ghosting fire promotes the instability of spray fire and large fluctuation of its height, which provides help to its self-extinguishing. With increasing the injecting pressure or the nozzle diameter, the self-extinguishing time decreases. It is found that the self-extinguishing time is approximately in inverse relation with injecting flow rate. Additionally, we also observed the occurrence of two-phase deflagration just after ignition, and it accelerates the spray fire growth and induces a larger fire height than the following quasi-steady spray fire. The deflagration turns stronger with increasing the injecting pressure.

  9. STRATIFICATION OF PARTICULATE AND VOC POLLUTANTS IN PAINT SPRAY BOOTHS

    EPA Science Inventory

    The paper discusses flow management as part of a joint EPA/U.S. Air Force program on emissions from paint spray booths. he goal of the program is to identify and develop efficienct and economical emissions control concepts for this source. low management is one potential solution...

  10. Log-normal spray drop distribution...analyzed by two new computer programs

    Treesearch

    Gerald S. Walton

    1968-01-01

    Results of U.S. Forest Service research on chemical insecticides suggest that large drops are not as effective as small drops in carrying insecticides to target insects. Two new computer programs have been written to analyze size distribution properties of drops from spray nozzles. Coded in Fortran IV, the programs have been tested on both the CDC 6400 and the IBM 7094...

  11. A strategy for emergency treatment of Schistosoma japonicum-infested water

    PubMed Central

    2011-01-01

    Background Schistosomiasis japonica, caused by contact with Schistosoma japonicum cercaria-infested water when washing, bathing or production, remains a major public-health concern in China. The purpose of the present study was to investigate the effect of a suspension concentrate of niclosamide (SCN) on killing cercaria of S. japonicum that float on the water surface, and its toxicity to fish, so as to establish an emergency-treatment intervention for rapidly killing cercaria and eliminating water infectivity. Results At 30 min after spraying 100 mg/L SCN, with niclosamide dosages of 0.01, 0.02, 0.03, 0.04 g/m2, the water infectivity reduced significantly and no infectivity was found at 60 min after spraying SCN. The surface of static water was sprayed with 100 mg/L SCN, the peak concentration was found at 0 min, and the solution diffused to site with a water depth of 10 cm after 10 min. 30 min later, SCN diffused to the whole water body, and distributed evenly. After spraying 100 mg/L SCN onto the surface of the water with a volume of(3.14 × 202×50)cm3, with niclosamide dosages of 0.02 g/m2, 96 h later, no death of zebra fish was observed. Conclusions By spraying 100 mg/L SCN, with a niclosamide dosage of 0.02 g/m2 onto the surface of S. japonicum-infested water, infectivity of the water can be eliminated after 30-60 min, and there is no evident toxicity to fish. This cercaria-killing method, as an emergency-treatment intervention for infested water, can be applied in those forecasting and early warning systems for schistosomiasis. PMID:22047607

  12. The Corrosion Behavior of Cold Sprayed Zinc Coatings on Mild Steel Substrate

    NASA Astrophysics Data System (ADS)

    Chavan, Naveen Manhar; Kiran, B.; Jyothirmayi, A.; Phani, P. Sudharshan; Sundararajan, G.

    2013-04-01

    Zinc and its alloy coatings have been used extensively for the cathodic protection of steel. Zinc coating corrodes in preference to the steel substrate due to its negative corrosion potential. Numerous studies have been conducted on the corrosion behavior of zinc and its alloy coatings deposited using several techniques viz., hot dip galvanizing, electrodeposition, metalizing or thermal spray etc. Cold spray is an emerging low temperature variant of thermal spray family which enables deposition of thick, dense, and pure coatings at a rapid rate with an added advantage of on-site coating of steel structures. In the present study, the corrosion characteristics of cold sprayed zinc coatings have been investigated for the first time. In addition, the influence of heat treatment of zinc coating at a temperature of 150 °C on its corrosion behavior has also been addressed.

  13. Emergency mosquito aerial spray response to the 2004 Florida hurricanes Charley, Frances, Ivan, and Jeanne: an overview of control results.

    PubMed

    Simpson, Jennifer E

    2006-09-01

    In total, 43 aerial spray missions were conducted in 26 Florida counties to control mosquito populations after each of the 4 hurricanes making landfall in Florida in 2004. Mosquitoes were trapped before and after each spray mission to determine the percentage (%) of control for the West Nile virus vector Culex nigripalpus (64.1%), the floodwater pest mosquito Psorophora columbiae (69.7%), and for all species combined (67.7%). A discussion on these results and suggestions for future efforts are presented.

  14. Development of the improved helicopter icing spray system (IHISS)

    NASA Technical Reports Server (NTRS)

    Peterson, Andrew A.; Jenks, Mark D.; Gaitskill, William H.

    1989-01-01

    Boeing Helicopters has been awarded a contract by the U.S. Army to design, fabricate and test a replacement for the existing Helicopter Icing Spray System (HISS). The Improved Hiss (IHISS), capable of deployment from any CH-47D helicopter, will include new icing spray nozzles and pneumatic pressure source, and a significantly larger water tank and spray boom. Results are presented for extensive bench and icing tunnel test programs used to select and modify an improved spray nozzle and validate spray boom aerodynamic characteristics. The resulting system will provide a significantly larger icing cloud with droplet characteristics closely matching natural icing conditions.

  15. High Fidelity Simulation of Atomization in Diesel Engine Sprays

    DTIC Science & Technology

    2015-09-01

    ARL-RP-0555 ● SEP 2015 US Army Research Laboratory High Fidelity Simulation of Atomization in Diesel Engine Sprays by L Bravo...ARL-RP-0555 ● SEP 2015 US Army Research Laboratory High Fidelity Simulation of Atomization in Diesel Engine Sprays by L...Simulation of Atomization in Diesel Engine Sprays 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) L Bravo, CB Ivey, D

  16. PILOT-SCALE PARAMETRIC TESTING OF SPRAY DRYER SO2 SCRUBBER FOR LOW-TO-MODERATE SULFUR COAL UTILITY APPLICATIONS

    EPA Science Inventory

    The report gives results of a comprehensive, pilot, dry, SO2 scrubbing test program to determine the effects of process variables on SO2 removal. In the spray dryer, stoichiometric ratio, flue gas temperature approach to adiabatic saturation, and temperature drop across the spray...

  17. Landscape analysis software tools

    Treesearch

    Don Vandendriesche

    2008-01-01

    Recently, several new computer programs have been developed to assist in landscape analysis. The “Sequential Processing Routine for Arraying Yields” (SPRAY) program was designed to run a group of stands with particular treatment activities to produce vegetation yield profiles for forest planning. SPRAY uses existing Forest Vegetation Simulator (FVS) software coupled...

  18. Thermal Spray Applications in Electronics and Sensors: Past, Present, and Future

    NASA Astrophysics Data System (ADS)

    Sampath, Sanjay

    2010-09-01

    Thermal spray has enjoyed unprecedented growth and has emerged as an innovative and multifaceted deposition technology. Thermal spray coatings are crucial to the enhanced utilization of various engineering systems. Industries, in recognition of thermal spray's versatility and economics, have introduced it into manufacturing environments. The majority of modern thermal spray applications are "passive" protective coatings, and they rarely perform an electronic function. The ability to consolidate dissimilar material multilayers without substrate thermal loading has long been considered a virtue for thick-film electronics. However, the complexity of understanding/controlling materials functions especially those resulting from rapid solidification and layered assemblage has stymied expansion into electronics. That situation is changing: enhancements in process/material science are allowing reconsideration for novel electronic/sensor devices. This review critically examines past efforts in terms of materials functionality from a device perspective, along with ongoing/future concepts addressing the aforementioned deficiencies. The analysis points to intriguing future possibilities for thermal spray technology in the world of thick-film sensors.

  19. From drop impact physics to spray cooling models: a critical review

    NASA Astrophysics Data System (ADS)

    Breitenbach, Jan; Roisman, Ilia V.; Tropea, Cameron

    2018-03-01

    Spray-wall interaction is an important process encountered in a large number of existing and emerging technologies and is the underlying phenomenon associated with spray cooling. Spray cooling is a very efficient technology, surpassing all other conventional cooling methods, especially those not involving phase change and not exploiting the latent heat of vaporization. However, the effectiveness of spray cooling is dependent on a large number of parameters, including spray characteristics like drop size, velocity and number density, the surface morphology, but also on the temperature range and thermal properties of the materials involved. Indeed, the temperature of the substrate can have significant influence on the hydrodynamics of drop and spray impact, an aspect which is seldom considered in model formulation. This process is extremely complex, thus most design rules to date are highly empirical in nature. On the other hand, significant theoretical progress has been made in recent years about the interaction of single drops with heated walls and improvements to the fundamentals of spray cooling can now be anticipated. The present review has the objective of summarizing some of these recent advances and to establish a framework for future development of more reliable and universal physics-based correlations to describe quantities involved in spray cooling.

  20. Design of a new nozzle for direct current plasma guns with improved spraying parameters

    NASA Astrophysics Data System (ADS)

    Jankovic, M.; Mostaghimi, J.; Pershin, V.

    2000-03-01

    A new design is proposed for direct current plasma spray gas-shroud attachments. It has curvilinearly shaped internal walls aimed toward elimination of the cold air entrainment, recorded for commercially available conical designs of the shrouded nozzle. The curvilinear nozzle design was tested; it proved to be capable of withstanding high plasma temperatures and enabled satisfactory particle injection. Parallel measurements with an enthalpy probe were performed on the jet emerging from two different nozzles. Also, corresponding calculations were made to predict the plasma flow parameters and the particle parameters. Adequate spray tests were performed by spraying iron-aluminum and MCrAlY coatings onto stainless steel substrates. Coating analyses were performed, and coating qualities, such as microstructure, open porosity, and adhesion strength, were determined. The results indicate that the coatings sprayed with a curvilinear nozzle exhibited lower porosity, higher adhesion strength, and an enhanced microstructure.

  1. Stabilization and application of Bt

    Treesearch

    A. Villaveces; I. Goldman; B. Carlton; C. H. Himel

    1985-01-01

    This research report is concerned with: 1). A field application program using encapsulated Bt. The objectives of that program involved spray physics and the delineation of the critical parameters inherent in the delivery of Bt sprays to the microhabitat of the spruce budworm. The field application work was carried out jointly with Dr. Alam Sundaram and the Forest Pest...

  2. A numerical simulation of the dispersal of aerial sprays

    NASA Technical Reports Server (NTRS)

    Bragg, M. B.

    1981-01-01

    A computer program was developed to predict the trajectory, ground deposition, and drift of liquid sprays injected into the wake of an agricultural aircraft in ground effect. The program uses a horseshoe vortex wake model and includes the effects of liquid droplet evaporation, crosswind, the propeller slipstream, ground effect, and tunnel walls on small scale models. This user's guide includes several case examples demonstrating user options. A complete listing of the FORTRAN program is provided.

  3. Engineering a new class of thermal spray nano-based microstructures from agglomerated nanostructured particles, suspensions and solutions: an invited review

    NASA Astrophysics Data System (ADS)

    Fauchais, P.; Montavon, G.; Lima, R. S.; Marple, B. R.

    2011-03-01

    From the pioneering works of McPherson in 1973 who identified nanometre-sized features in thermal spray conventional alumina coatings (using sprayed particles in the tens of micrometres size range) to the most recent and most advanced work aimed at manufacturing nanostructured coatings from nanometre-sized feedstock particles, the thermal spray community has been involved with nanometre-sized features and feedstock for more than 30 years. Both the development of feedstock (especially through cryo-milling, and processes able to manufacture coatings structured at the sub-micrometre or nanometre sizes, such as micrometre-sized agglomerates made of nanometre-sized particles for feedstock) and the emergence of thermal spray processes such as suspension and liquid precursor thermal spray techniques have been driven by the need to manufacture coatings with enhanced properties. These techniques result in two different types of coatings: on the one hand, those with a so-called bimodal structure having nanometre-sized zones embedded within micrometre ones, for which the spray process is similar to that of conventional coatings and on the other hand, sub-micrometre or nanostructured coatings achieved by suspension or solution spraying. Compared with suspension spraying, solution precursor spraying uses molecularly mixed precursors as liquids, avoiding a separate processing route for the preparation of powders and enabling the synthesis of a wide range of oxide powders and coatings. Such coatings are intended for use in various applications ranging from improved thermal barrier layers and wear-resistant surfaces to thin solid electrolytes for solid oxide fuel cell systems, among other numerous applications. Meanwhile these processes are more complex to operate since they are more sensitive to parameter variations compared with conventional thermal spray processes. Progress in this area has resulted from the unique combination of modelling activities, the evolution of diagnostic tools and strategies, and experimental advances that have enabled the development of a wide range of coating structures exhibiting in numerous cases unique properties. Several examples are detailed. In this paper the following aspects are presented successively (i) the two spray techniques used for manufacturing such coatings: thermal plasma and HVOF, (ii) sensors developed for in-flight diagnostics of micrometre-sized particles and the interaction of a liquid and hot gas flow, (iii) three spray processes: conventional spraying using micrometre-sized agglomerates of nanometre-sized particles, suspension spraying and solution spraying and (iv) the emerging issues resulting from the specific structures of these materials, particularly the characterization of these coatings and (v) the potential industrial applications. Further advances require the scientific and industrial communities to undertake new research and development activities to address, understand and control the complex mechanisms occurring, in particular, thermal flow—liquid drops or stream interactions when considering suspension and liquid precursor thermal spray techniques. Work is still needed to develop new measurement devices to diagnose in-flight droplets or particles below 2 µm average diameter and to validate that the assumptions made for liquid-hot gas interactions. Efforts are also required to further develop some of the characterization protocols suitable to address the specificities of such nanostructured coatings, as some existing 'conventional' protocols usually implemented on thermal spray coatings are not suitable anymore, in particular to address the void network architectures from which numerous coatings properties are derived.

  4. Liquid rocket performance computer model with distributed energy release

    NASA Technical Reports Server (NTRS)

    Combs, L. P.

    1972-01-01

    Development of a computer program for analyzing the effects of bipropellant spray combustion processes on liquid rocket performance is described and discussed. The distributed energy release (DER) computer program was designed to become part of the JANNAF liquid rocket performance evaluation methodology and to account for performance losses associated with the propellant combustion processes, e.g., incomplete spray gasification, imperfect mixing between sprays and their reacting vapors, residual mixture ratio striations in the flow, and two-phase flow effects. The DER computer program begins by initializing the combustion field at the injection end of a conventional liquid rocket engine, based on injector and chamber design detail, and on propellant and combustion gas properties. It analyzes bipropellant combustion, proceeding stepwise down the chamber from those initial conditions through the nozzle throat.

  5. 40 CFR 264.32 - Required equipment.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... supply water hose streams, or foam producing equipment, or automatic sprinklers, or water spray systems... communications or alarm system capable of providing immediate emergency instruction (voice or signal) to facility...-held two-way radio, capable of summoning emergency assistance from local police departments, fire...

  6. 40 CFR 264.32 - Required equipment.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... supply water hose streams, or foam producing equipment, or automatic sprinklers, or water spray systems... communications or alarm system capable of providing immediate emergency instruction (voice or signal) to facility...-held two-way radio, capable of summoning emergency assistance from local police departments, fire...

  7. 40 CFR 264.32 - Required equipment.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... supply water hose streams, or foam producing equipment, or automatic sprinklers, or water spray systems... communications or alarm system capable of providing immediate emergency instruction (voice or signal) to facility...-held two-way radio, capable of summoning emergency assistance from local police departments, fire...

  8. 40 CFR 264.32 - Required equipment.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... supply water hose streams, or foam producing equipment, or automatic sprinklers, or water spray systems... communications or alarm system capable of providing immediate emergency instruction (voice or signal) to facility...-held two-way radio, capable of summoning emergency assistance from local police departments, fire...

  9. Pheromone-assisted techniques to improve the efficacy of insecticide sprays against Linepithema humile (Hymenoptera: Formicidae).

    PubMed

    Choe, Dong-Hwan; Tsai, Kasumi; Lopez, Carlos M; Campbell, Kathleen

    2014-02-01

    Outdoor residual sprays are among the most common methods for targeting pestiferous ants in urban pest management programs. If impervious surfaces such as concrete are treated with these insecticides, the active ingredients can be washed from the surface by rain or irrigation. As a result, residual sprays with fipronil and pyrethroids are found in urban waterways and aquatic sediments. Given the amount of insecticides applied to urban settings for ant control and their possible impact on urban waterways, the development of alternative strategies is critical to decrease the overall amounts of insecticides applied, while still achieving effective control of target ant species. Herein we report a "pheromone-assisted technique" as an economically viable approach to maximize the efficacy of conventional sprays targeting the Argentine ant. By applying insecticide sprays supplemented with an attractive pheromone compound, (Z)-9-hexadecenal, Argentine ants were diverted from nearby trails and nest entrances and subsequently exposed to insecticide residues. Laboratory experiments with fipronil and bifenthrin sprays indicated that the overall kill of the insecticides on Argentine ant colonies was significantly improved (57-142% increase) by incorporating (Z)-9-hexadecenal in the insecticide sprays. This technique, once it is successfully implemented in practical pest management programs, has the potential of providing maximum control efficacy with reduced amount of insecticides applied in the environment.

  10. Laser Doppler velocimeter aerial spray measurements

    NASA Technical Reports Server (NTRS)

    Zalay, A. D.; Eberle, W. R.; Howle, R. E.; Shrider, K. R.

    1978-01-01

    An experimental research program for measuring the location, spatial extent, and relative concentration of airborne spray clouds generated by agricultural aircraft is described. The measurements were conducted with a ground-based laser Doppler velocimeter. The remote sensing instrumentation, experimental tests, and the results of the flight tests are discussed. The cross section of the aerial spray cloud and the observed location, extent, and relative concentration of the airborne particulates are presented. It is feasible to use a mobile laser Doppler velocimeter to track and monitor the transport and dispersion of aerial spray generated by an agricultural aircraft.

  11. Studies on the use of helicopters for oil spill clearance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Martinelli, F.N.

    A program of work was undertaken to assess the use of a commercially available underslung cropspraying bucket for spraying oil spill dispersants. The study consisted of land-based trials to measure relevant parameters of the spray and the effect on these parameters of spray height and dispersant viscosity. A sea trial was undertaken to observe the system under realistic conditions. (Copyright (c) Crown Copyright.)

  12. [Injuries from pepper spray used for self defense: analysis of 15 cases managed in an emergency chemical decontamination area].

    PubMed

    Amigó, Montserrat; Fernández, Fuensanta; Velasco, Verónica; Nogué, Santiago

    2016-10-01

    We analyzed epidemiologic and clinical characteristics, treatment received, and clinical course in cases of pepper spray injury treated in the chemical decontamination area of an emergency department over a 5-year period. A total of 15 patients with a mean (SD) age of 25 (8.3) years were included. Thirteen were men and 53% were foreign-born. All uses of pepper spray occurred during muggings that to place mainly in the early hours of the morning (66.7% between 4:30 and 6:30 AM). Two or more attackers were injured in 60% of the events. Seventy-three percent of the attacks took place on the street and the median delay in reaching the emergency department was 30 minutes. The face and eyes were usually injured, and symptoms included itching, irritation, burning, and pain. On arrival, the patients were treated immediately (mean delay, 3 minutes) with hypertonic saline, an amphoteric surfactant, and a chelating agent in 80% of the cases, in which improvement was substantial as mean pain scale scores changed from 7.2 on admission to 3 on discharge (P=.009). Patients spent an average of 40 minutes in the treatment area. Eleven patients required further care from an ophthalmologist and topical medication for symptoms. Outcomes were good and there were no complications in any of the cases. We conclude that pepper sprays are being used as an aid to self defense in muggings in our community. Decontamination measures have priority as they alleviate symptoms and prevent long-lasting effects.

  13. 40 CFR 63.801 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... devices used to reduce emissions to the atmosphere. Conventional air spray means a spray coating method in... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS FOR SOURCE CATEGORIES (CONTINUED) National Emission...

  14. 40 CFR 63.801 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... devices used to reduce emissions to the atmosphere. Conventional air spray means a spray coating method in... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS FOR SOURCE CATEGORIES (CONTINUED) National Emission...

  15. 40 CFR 63.801 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... devices used to reduce emissions to the atmosphere. Conventional air spray means a spray coating method in... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS FOR SOURCE CATEGORIES (CONTINUED) National Emission...

  16. 40 CFR 63.801 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... devices used to reduce emissions to the atmosphere. Conventional air spray means a spray coating method in... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS FOR SOURCE CATEGORIES (CONTINUED) National Emission...

  17. 40 CFR 267.32 - What equipment am I required to have?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... supply water hose streams, or foam-producing equipment, or automatic sprinklers, or water spray systems. ... alarm system capable of providing immediate emergency instruction (voice or signal) to facility...-held two-way radio, capable of summoning emergency assistance from local police departments, fire...

  18. 40 CFR 267.32 - What equipment am I required to have?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... supply water hose streams, or foam-producing equipment, or automatic sprinklers, or water spray systems. ... alarm system capable of providing immediate emergency instruction (voice or signal) to facility...-held two-way radio, capable of summoning emergency assistance from local police departments, fire...

  19. 40 CFR 267.32 - What equipment am I required to have?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... supply water hose streams, or foam-producing equipment, or automatic sprinklers, or water spray systems. ... alarm system capable of providing immediate emergency instruction (voice or signal) to facility...-held two-way radio, capable of summoning emergency assistance from local police departments, fire...

  20. 40 CFR 267.32 - What equipment am I required to have?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... supply water hose streams, or foam-producing equipment, or automatic sprinklers, or water spray systems. ... alarm system capable of providing immediate emergency instruction (voice or signal) to facility...-held two-way radio, capable of summoning emergency assistance from local police departments, fire...

  1. 40 CFR 267.32 - What equipment am I required to have?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... supply water hose streams, or foam-producing equipment, or automatic sprinklers, or water spray systems. ... alarm system capable of providing immediate emergency instruction (voice or signal) to facility...-held two-way radio, capable of summoning emergency assistance from local police departments, fire...

  2. Thermal barrier coating life prediction model development

    NASA Technical Reports Server (NTRS)

    Strangman, T. E.; Neumann, J. F.; Tasooji, A.

    1985-01-01

    This program focuses on predicting the lives of two types of strain-tolerant and oxidation-resistant thermal barrier coating (TBC) systems that are produced by commercial coating suppliers to the gas turbine industry. The plasma-sprayed TBC system is composed of a low pressure, plasma sprayed applied, oxidation resistant NiCrAlY bond coating. The other system is an air plasma sprayed yttria (8 percent) partially stabilized zirconia insulative layer.

  3. Weapons Retrieved After the Implementation of Emergency Department Metal Detection.

    PubMed

    Malka, S Terez; Chisholm, Robin; Doehring, Marla; Chisholm, Carey

    2015-09-01

    Several high-profile violent incidents have occurred within emergency departments (EDs). There are no recent studies reporting the effectiveness of ED metal detection. Our aim was to assess the effect of metal detection on ED weapons retrieval. In September 2011, a metal detector was installed at the entrance of an urban, high-volume teaching hospital ED. The security company recorded retrieved firearms, knives, chemical sprays, and other weapons. We performed qualitative analysis of weapons retrieval data for a 26-month period. A total of 5877 weapons were retrieved, an average of 218 per month: 268 firearms, 4842 knives, 512 chemical sprays, and 275 other weapons, such as brass knuckles, stun guns, and box cutters. The number of retrieved guns decreased from 2012 to 2013 (from 182 to 47), despite an increase in metal detection hours from 8 h per day to 16 h per day. The number of retrieved knives, chemical sprays, and other weapons increased. Recovered knives increased from 2062 in 2012 to 2222 in 2013, chemical sprays increased from 170 to 305, and other weapons increased from 51 to 201. A large number of weapons were retrieved after the initiation of metal detection in the ED entrance. Increasing hours of metal detection increased the number of retrieved knives, chemical sprays, and other weapons. Retrieved firearms decreased after increasing metal detection hours. Metal detection in the ED entrance is effective in reducing entrance of weapons into the ED. Metal detectors may offer additional benefit in reducing attempts to enter with firearms. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. A decision-support tool to predict spray deposition of insecticides in commercial potato fields and its implications for their performance.

    PubMed

    Nansen, Christian; Vaughn, Kathy; Xue, Yingen; Rush, Charlie; Workneh, Fekede; Goolsby, John; Troxclair, Noel; Anciso, Juan; Gregory, Ashley; Holman, Daniel; Hammond, Abby; Mirkov, Erik; Tantravahi, Pratyusha; Martini, Xavier

    2011-08-01

    Approximately US $1.3 billion is spent each year on insecticide applications in major row crops. Despite this significant economic importance, there are currently no widely established decision-support tools available to assess suitability of spray application conditions or of the predicted quality or performance of a given commercial insecticide applications. We conducted a field study, involving 14 commercial spray applications with either fixed wing airplane (N=8) or ground rig (N=6), and we used environmental variables as regression fits to obtained spray deposition (coverage in percentage). We showed that (1) ground rig applications provided higher spray deposition than aerial applications, (2) spray deposition was lowest in the bottom portion of the canopy, (3) increase in plant height reduced spray deposition, (4) wind speed increased spray deposition, and (5) higher ambient temperatures and dew point increased spray deposition. Potato psyllid, Bactericera cockerelli (Sulc) (Hemiptera: Triozidae), mortality increased asymptotically to approximately 60% in response to abamectin spray depositions exceeding around 20%, whereas mortality of psyllid adults reached an asymptotic response approximately 40% when lambda-cyhalothrin/thiamethoxam spray deposition exceeded 30%. A spray deposition support tool was developed (http://pilcc.tamu.edu/) that may be used to make decisions regarding (1) when is the best time of day to conduct spray applications and (2) selecting which insecticide to spray based on expected spray deposition. The main conclusion from this analysis is that optimization of insecticide spray deposition should be considered a fundamental pillar of successful integrated pest management programs to increase efficiency of sprays (and therefore reduce production costs) and to reduce risk of resistance development in target pest populations.

  5. 46 CFR 112.15-5 - Final emergency loads.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... or gas turbines that drive emergency generators; and (3) General alarm batteries. (d) One of the... of the subchapter under which the vessel is certificated. (f) Each sprinkler system, water spray extinguishing system, or foam system pump. (g) If necessary, the lube oil pump for each propulsion turbine and...

  6. 46 CFR 112.15-5 - Final emergency loads.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... or gas turbines that drive emergency generators; and (3) General alarm batteries. (d) One of the... of the subchapter under which the vessel is certificated. (f) Each sprinkler system, water spray extinguishing system, or foam system pump. (g) If necessary, the lube oil pump for each propulsion turbine and...

  7. 46 CFR 112.15-5 - Final emergency loads.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... or gas turbines that drive emergency generators; and (3) General alarm batteries. (d) One of the... of the subchapter under which the vessel is certificated. (f) Each sprinkler system, water spray extinguishing system, or foam system pump. (g) If necessary, the lube oil pump for each propulsion turbine and...

  8. A sticky situation: management of spray polyurethane foam insulation in body orifices.

    PubMed

    Sowerby, Robert J; Sowerby, Leigh J; Vinden, Chris

    2011-11-01

    Spray polyurethane foam insulation is commonly used in the construction industry to fill gaps, seal, and insulate. We present three cases of intentional spray foam insertion in body orifices and discuss the management of such situations in the emergency department. This series includes a case of oral foam insertion used in a suicide attempt by suffocation and two cases of rectal insertion. All of these cases had potential long-term consequences; one was life-threatening. To our knowledge, this is the first published report on the medical management and removal of foam insulation from body orifices. In all three cases, the foam insulation material was successfully removed after allowing the material to harden.

  9. Supercritical Saltwater Spray for Marine Cloud Brightening (MCB)

    NASA Astrophysics Data System (ADS)

    Neukermans, A.; Cooper, G. F.; Foster, J.; Galbraith, L. K.; Johnston, D.; Ormond, B.; Wang, Q.

    2012-12-01

    Solar Radiation Management (SRM), including both stratospheric sulfur aerosol delivery and MCB, has emerged as the leading contender for geoengineering. Field research in MCB would require a technique capable of producing 1017 salt nuclei/sec from a single source on a seagoing vessel. Spraying supercritical saltwater has emerged as a viable technology, at least for research purposes. Under optimum conditions a single 50-μm nozzle produces 1014 suitable nuclei/sec. Power consumption is high (1-2 MW), but 95% of the required energy is in the form of heat that can probably be obtained from wasted ship-engine heat. While its implementation is conceptually simple, the corrosive nature of supercritical saltwater makes the material requirements very demanding. Progress on this work is detailed.

  10. Evaluation of the efficacy of lambda-cyhalothrin applied as ultra-low volume and thermal fog for emergency control of Aedes aegypti in Honduras.

    PubMed

    Perich, M J; Sherman, C; Burge, R; Gill, E; Quintana, M; Wirtz, R A

    2001-12-01

    An extended-duration formulation of lambda-cyhalothrin (Demand CS) applied as either an ultra-low volume (ULV) or thermal fog spray from a new handheld sprayer (Terrier) against Aedes aegypti was evaluated in Honduras. Spray applications were made at the front door for 1 min or to each room for 15 sec, both for the ULV and thermal fog applications to houses in separate blocks for each treatment. The efficacy and duration of effectiveness of the spray was determined from sentinel caged mosquito mortality and collection of mosquitoes within houses with a backpack power aspirator. Sentinel caged mosquito mortality in both open and sequestered locations was 97-100% for all spray treatments, with control mortality less than 2%. Both ULV applications (front door and each room) provided 4 wk of significant control (P < 0.01) based on adult Ae. aegypti house collections.

  11. a Numerical Model for Flue Gas Desulfurization System.

    NASA Astrophysics Data System (ADS)

    Kim, Sung Joon

    The purpose of this work is to develop a reliable numerical model for spray dryer desulfurization systems. The shape of the spray dryer requires that a body fitted orthogonal coordinate system be used for the numerical model. The governing equations are developed in the general orthogonal coordinates and discretized to yield a system of algebraic equations. A turbulence model is also included in the numerical program. A new second order numerical scheme is developed and included in the numerical model. The trajectory approach is used to simulate the flow of the dispersed phase. Two-way coupling phenomena is modeled by this scheme. The absorption of sulfur dioxide into lime slurry droplets is simulated by a model based on gas -phase mass transfer. The program is applied to a typical spray dryer desulfurization system. The results show the capability of the program to predict the sensitivity of system performance to changes in operational parameters.

  12. INEL Spray-forming Research

    NASA Technical Reports Server (NTRS)

    Mchugh, Kevin M.; Key, James F.

    1993-01-01

    Spray forming is a near-net-shape fabrication technology in which a spray of finely atomized liquid droplets is deposited onto a suitably shaped substrate or mold to produce a coherent solid. The technology offers unique opportunities for simplifying materials processing without sacrificing, and oftentimes substantially improving, product quality. Spray forming can be performed with a wide range of metals and nonmetals, and offers property improvements resulting from rapid solidification (e.g., refined microstructures, extended solid solubilities and reduced segregation). Economic benefits result from process simplification and the elimination of unit operations. Researchers at the Idaho National Engineering Laboratory (INEL) are developing spray-forming technology for producing near-net-shape solids and coatings of a variety of metals, polymers, and composite materials. Results from several spray forming programs are presented to illustrate the range of capabilities of the technique as well as the accompanying technical and economic benefits. Low-carbon steel strip greater than 0.75 mm thick and polymer membranes for gas/gas and liquid/liquid separations that were spray formed are discussed; recent advances in spray forming molds, dies, and other tooling using low-melting-point metals are described.

  13. Near-net-shape manufacturing: Spray-formed metal matrix composites and tooling

    NASA Technical Reports Server (NTRS)

    Mchugh, Kevin M.

    1994-01-01

    Spray forming is a materials processing technology in which a bulk liquid metal is converted to a spray of fine droplets and deposited onto a substrate or pattern to form a near-net-shape solid. The technology offers unique opportunities for simplifying materials processing without sacrificing, and oftentimes substantially improving, product quality. Spray forming can be performed with a wide range of metals and nonmetals, and offers property improvements resulting from rapid solidification (e.g. refined microstructures, extended solid solubilities and reduced segregation). Economic benefits result from process simplification and the elimination of unit operations. The Idaho National Engineering Laboratory is developing a unique spray-forming method, the Controlled Aspiration Process (CAP), to produce near-net-shape solids and coatings of metals, polymers, and composite materials. Results from two spray-accompanying technical and economic benefits. These programs involved spray forming aluminum strip reinforced with SiC particulate, and the production of tooling, such as injection molds and dies, using low-melting-point metals.

  14. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT, ANEST IWATA CORPORATION W400-LV SPRAY GUN

    EPA Science Inventory

    Under EPA’s Environmental Technology Verification program, which provides objective and scientific third party analysis of new technology that can benefit the environment, the pollution prevention capabilities of a high transfer efficiency liquid spray gun was tested. This ...

  15. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT, SHARPE MANUFACTURING TITANIUM T1-CG SPRAY GUN

    EPA Science Inventory

    Under EPA’s Environmental Technology Verification program, which provides objective and scientific third party analysis of new technology that can benefit the environment, the pollution prevention capabilities of a high transfer efficiency liquid spray gun was tested. This ...

  16. EVALUATION OF SUPERCRITICAL CARBON DIOXIDE TECHNOLOGY TO REDUCE SOLVENT IN SPRAY COATING APPLICATIONS

    EPA Science Inventory

    This evaluation, part of the Pollution Prevention Clean Technology Demonstration (CTD) Program, addresses the product quality, waste reduction, and economic issues of spray paint application using supercritical carbon dioxide (CO2). Anion Carbide has developed this technology and...

  17. Modeling spray/puddle dissolution processes for deep-ultraviolet acid-hardened resists

    NASA Astrophysics Data System (ADS)

    Hutchinson, John M.; Das, Siddhartha; Qian, Qi-De; Gaw, Henry T.

    1993-10-01

    A study of the dissolution behavior of acid-hardened resists (AHR) was undertaken for spray and spray/puddle development processes. The Site Services DSM-100 end-point detection system is used to measure both spray and puddle dissolution data for a commercially available deep-ultraviolet AHR resist, Shipley SNR-248. The DSM allows in situ measurement of dissolution rate on the wafer chuck and hence allows parameter extraction for modeling spray and puddle processes. The dissolution data for spray and puddle processes was collected across a range of exposure dose and postexposure bake temperature. The development recipe was varied to decouple the contribution of the spray and puddle modes to the overall dissolution characteristics. The mechanisms involved in spray versus puddle dissolution and the impact of spray versus puddle dissolution on process performance metrics has been investigated. We used the effective-dose-modeling approach and the measurement capability of the DSM-100 and developed a lumped parameter model for acid-hardened resists that incorporates the effects of exposure, postexposure bake temperature and time, and development condition. The PARMEX photoresist-modeling program is used to determine parameters for the spray and for the puddle process. The lumped parameter AHR model developed showed good agreement with experimental data.

  18. Bug spray poisoning

    MedlinePlus

    Cannon RD, Ruha A-M. Insecticides, herbicides, and rodenticides. In: Adams JG, ed. Emergency Medicine: Clinical Essentials . 2nd ed. Philadelphia, PA: Elsevier Saunders; 2013:chap 146. Freedman DO. Protection ...

  19. Spray Forming Aluminum - Final Report (Phase II)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    D. D. Leon

    1999-07-08

    The U.S. Department of Energy - Office of Industrial Technology (DOE) has an objective to increase energy efficient and enhance competitiveness of American metals industries. To support this objective, ALCOA Inc. entered into a cooperative program to develop spray forming technology for aluminum. This Phase II of the DOE Spray Forming Program would translate bench scale spray forming technology into a cost effective world class process for commercialization. Developments under DOE Cooperative Agreement No. DE-FC07-94ID13238 occurred during two time periods due to budgetary constraints; April 1994 through September 1996 and October 1997 and December 1998. During these periods, ALCOA Incmore » developed a linear spray forming nozzle and specific support processes capable of scale-up for commercial production of aluminum sheet alloy products. Emphasis was given to alloys 3003 and 6111, both being commercially significant alloys used in the automotive industry. The report reviews research performed in the following areas: Nozzel Development, Fabrication, Deposition, Metal Characterization, Computer Simulation and Economics. With the formation of a Holding Company, all intellectual property developed in Phases I and II of the Project have been documented under separate cover for licensing to domestic producers.« less

  20. Experimental study on the effect of nozzle hole-to-hole angle on the near-field spray of diesel injector using fast X-ray phase-contrast imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Xusheng; Moon, Seoksu; Gao, Jian

    Fuel atomization and vaporization process play a critical role in determining the engine combustion and emission. The primary near-nozzle breakup is the vital link between the fuel emerging from the nozzle and the fully atomized spray. In this study, the near-nozzle spray characteristics of diesel injector with different umbrella angle (UA) were investigated using high-speed X-ray phase-contrast imaging and quantitative image processing. A classic ‘dumbbell’ profile of spray width (SW) composed of three stages: opening stage, semisteady stage and closing stage. The SW peak of two-hole injectors was more than twice of that of single-hole injector at the opening andmore » closing stages, corresponding to the hollow-cone spray. This indicated the vortex flow was formed with the increase of the UA. The higher injection pressure had little influence on the SW while led to earlier breakup closer to the nozzle. Significant fuel effect on the SW at higher needle lift was found. However, this effect could be neglect at lower needle lift due to the leading role of internal flow and cavitation on the near-field spray characteristics. In addition, the morphology-based breakup process was observed, which highlighted the important effect of internal flow on the spray development. The possibility of using hollow-cone spray in diesel injector was also discussed.« less

  1. Analysis of several Boolean operation based trajectory generation strategies for automotive spray applications

    NASA Astrophysics Data System (ADS)

    Gao, Guoyou; Jiang, Chunsheng; Chen, Tao; Hui, Chun

    2018-05-01

    Industrial robots are widely used in various processes of surface manufacturing, such as thermal spraying. The established robot programming methods are highly time-consuming and not accurate enough to fulfil the demands of the actual market. There are many off-line programming methods developed to reduce the robot programming effort. This work introduces the principle of several based robot trajectory generation strategy on planar surface and curved surface. Since the off-line programming software is widely used and thus facilitates the robot programming efforts and improves the accuracy of robot trajectory, the analysis of this work is based on the second development of off-line programming software Robot studio™. To meet the requirements of automotive paint industry, this kind of software extension helps provide special functions according to the users defined operation parameters. The presented planning strategy generates the robot trajectory by moving an orthogonal surface according to the information of coating surface, a series of intersection curves are then employed to generate the trajectory points. The simulation results show that the path curve created with this method is successive and smooth, which corresponds to the requirements of automotive spray industrial applications.

  2. Spray combustion at normal and reduced gravity in counterflow and co-flow configurations

    NASA Technical Reports Server (NTRS)

    Gomez, Alessandro; Chen, Gung

    1995-01-01

    Liquid fuel dispersion in practical systems is typically achieved by spraying the fuel into a polydisperse distribution of droplets evaporating and burning in a turbulent gaseous environment In view of the nearly insurmountable difficulties of this two-phase flow, a systematic study of spray evaporation and burning in configurations of gradually increasing levels of complexity, starting from laminar sprays to fully turbulent ones, would be useful. A few years ago we proposed to use an electrostatic spray of charged droplets for this type of combustion experiments under well-defined conditions. In the simplest configuration, a liquid is fed into a small metal tube maintained at several kilovolts relative to a ground electrode few centimeters away. Under the action of the electric field, the liquid meniscus at the outlet of the capillary takes a conical shape, with a thin jet emerging from the cone tip (cone-jet mode). This jet breaks up farther downstream into a spray of charged droplets - the so-called ElectroSpray (ES). Several advantages distinguish the electrospray from alternative atomization techniques: (1) it can produce quasi-monodisperse droplets over a phenomenal size range; (2) the atomization, that is strictly electrostatic, is decoupled from gas flow processes, which provides some flexibility in the selection and control of the experimental conditions; (3) the Coulombic repulsion of homopolarly charged droplets induces spray self-dispersion and prevents droplet coalescence; (4) the ES provides the opportunity of studying regimes of slip between droplets and host gas without compromising the control of the spray properties; and (5) the compactness and potential controllability of this spray generation system makes it appealing for studies in reduced-gravity environments aimed at isolating the spray behavior from natural convection complications. With these premises, in March 1991 we initiated a series of experiments under NASA sponsorship (NAG3-1259 and 1688) in which the ES was used as a research tool to examine spray combustion in counter-flow and co-flow spray diffusion flames, as summarized below. The ultimate objective of this investigation is to examine the formation and burning of sprays of liquid fuels, at both normal and reduced gravity, first in laminar regimes and then in turbulent ones.

  3. Validation of HVOF Thermal Spray Coatings as a Replacement for Hard Chrome Plating on Hydraulic/Pneumatic Actuators

    DTIC Science & Technology

    2007-12-01

    Projects Agency (DARPA). The program evaluated HVOF, physical vapor deposition (PVD) and laser cladding , and concluded that HVOF was the best overall...components such as titanium flap tracks. 5 2.0 TECHNOLOGY DESCRIPTION 2.1 TECHNOLOGY DEVELOPMENT AND APPLICATION Technology background and...theory of operation: High-velocity oxygen-fuel (HVOF) is a standard commercial thermal spray process in which a powder of the material to be sprayed

  4. In situ X-ray study of the structural evolution of gold nano-domains by spray deposition on thin conductive P3HT films.

    PubMed

    Al-Hussein, M; Schindler, M; Ruderer, M A; Perlich, J; Schwartzkopf, M; Herzog, G; Heidmann, B; Buffet, A; Roth, S V; Müller-Buschbaum, P

    2013-02-26

    Gold (Au) nanoparticles are deposited from aqueous solution onto one of the most used conductive polymers, namely poly(3-hexylthiophene) (P3HT), using airbrush deposition. We report on the structure formation and packing of the Au nanoparticles after a 5 s spray cycle. In situ grazing incidence small-angle X-ray scattering (GISAXS) measurements with 20 ms time resolution allow a real-time observation of the emergence and evolution of the microstructure during a spray cycle and subsequent solvent evaporation. The results reveal multistage nanoscale ordering of the Au nanoparticles during the spray cycle. Further ex situ atomic force microscopy measurements of the sprayed films showed the formation of Au monolayer islands on top of the polymer film. Our study suggests that the solvent-substrate interaction as well as solvent evaporation kinetics are important factors that need to be taken into consideration in order to grow a compact uniform monolayer film for the fabrication of ultrathin films using airbrush deposition.

  5. Integrated pest management of two-spotted mite Tetranychus urticae on greenhouse roses using petroleum spray oil and the predatory mite Phytoseiulus persimilis.

    PubMed

    Nicetic; Watson, D M; Beattie, G A; Meats, A; Zheng, J

    2001-01-01

    From 1995 to 1999, four experiments were conducted on greenhouse roses to assess the effectiveness of the nC24 petroleum spray oil (PSO), D-C-Tron Plus, against two-spotted mite, Tetranychus urticae Koch (Acarina: Tetranychidae), and to determine how the oil could be most efficiently and effectively used in combination with the predatory mite Phytoseiulus persimilis Athias-Henriot (Acarina: Phytoseiidae) in an integrated pest management program. The results showed that 0.5% PSO applied fortnightly to roses gave excellent protection from T urticae infestation when the mite population was not already established. However, PSO applied after roses were infested with T. urticae above the economic threshold only stabilised populations without reducing them below that threshold. Populations of P. persimilis in the upper and lower canopies were unchanged after two sprays of PSO at 7-day intervals, and application of PSO to the upper canopy was as effective in controlling T. urticae in the presence of P persimilis as spraying the entire plant. Combining PSO with P. persimilis gave better control of T. urticae than using P. persimilis alone. The most cost-effective use of PSO in the presence of P. persimilis is, therefore, to apply spray only to the upper canopy. This will not affect control of powdery mildew with PSO. Comparison of a control program for T urticae based on the monitored use of synthetic miticides with that based on calendar application of PSO revealed that both gave equally effective control. The benefits of combining PSO and P. persimilis in an integrated pest management program for T. urticae on roses over a program based on synthetic fungicides are discussed.

  6. JT9D ceramic outer air seal system refinement program

    NASA Technical Reports Server (NTRS)

    Gaffin, W. O.

    1982-01-01

    The abradability and durability characteristics of the plasma sprayed system were improved by refinement and optimization of the plasma spray process and the metal substrate design. The acceptability of the final seal system for engine testing was demonstrated by an extensive rig test program which included thermal shock tolerance, thermal gradient, thermal cycle, erosion, and abradability tests. An interim seal system design was also subjected to 2500 endurance test cycles in a JT9D-7 engine.

  7. Efficacy of Several Pesticide Products on Brown Widow Spider (Araneae: Theridiidae) Egg Sacs and Their Penetration Through the Egg Sac Silk.

    PubMed

    Vetter, Richard S; Tarango, Jacob; Campbell, Kathleen A; Tham, Christine; Hayashi, Cheryl Y; Choe, Dong-Hwan

    2016-02-01

    Information on pesticide effects on spiders is less common than for insects; similar information for spider egg sacs is scarcer in the open literature. Spider egg sacs are typically covered with a protective silk layer. When pesticides are directly applied to egg sacs, the silk might prevent active ingredients from reaching the eggs, blocking their insecticidal effect. We investigated the impact of six water-based pesticide sprays and four oil-based aerosol products against egg sacs of brown widow spiders, Latrodectus geometricus C. L. Koch. All water-based spray products except one failed to provide significant mortality to egg sacs, resulting in successful spiderling emergence from treated egg sacs at a similar rate to untreated egg sacs. In contrast to water-based sprays, oil-based aerosols provided almost complete control, with 94-100% prevention of spiderling emergence. Penetration studies using colored pesticide products indicated that oil-based aerosols were significantly more effective in penetrating egg sac silk than were the water-based sprays, delivering the active ingredients on most (>99%) of the eggs inside the sac. The ability of pesticides to penetrate spider egg sac silk and deliver lethal doses of active ingredients to the eggs is discussed in relation to the chemical nature of egg sac silk proteins. Our study suggests that pest management procedures primarily relying on perimeter application of water-based sprays might not provide satisfactory control of brown widow spider eggs. Determination of the most effective active ingredients and carrier characteristics warrant further research to provide more effective control options for spider egg sacs. © The Authors 2015. Published by Oxford University Press on behalf of Entomological Society of America. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  8. Solidifying agent and processing of blood used for the larval diet affect screwworm (Diptera: Calliphoridae) life-history parameters.

    PubMed

    Chaudhury, M F; Skoda, S R; Sagel, A

    2011-06-01

    Spray-dried whole bovine blood and a sodium polyacrylate polymer gel as a bulking and solidifying agent are among the constituents of the current larval diet for mass rearing screwworm, Cochliomyia hominivorax (Coquerel) (Diptera: Calliphoridae). Locally available, inexpensive dietary materials could reduce rearing cost and address an uncertain commercial supply of spray-dried blood. We compared efficacy of diet prepared from fresh bovine blood after decoagulation with sodium citrate or ethylenediaminetetraacetic acid (EDTA) or after mechanical defibrination, with the diet containing spray-dried blood using either gel or cellulose fiber as the bulking and solidifying agent. Several life-history parameters were compared among insects reared on each of the blood and bulking agent diets combination. Diets containing citrated blood yielded the lightest larval and pupal weights and fewest pupae. EDTA-treated blood with the gel also caused reductions. EDTA-treated blood with fiber yielded screwworms that were heavier and more numerous than those from the diet with citrated blood but lighter than those from the control diet using spray-dried blood. A reduction in percentage of adults emerging from pupae occurred from diets with both bulking agents using citrated blood and the diet using EDTA mixed with the gel bulking agent. As a group, the cellulose-fiber diets performed better than the gel diets. Larval diet did not affect adult longevity, weight of the eggs deposited by the females that emerged or subsequent egg hatch. Parameter measurements of insects from both defibrinated blood diets were similar to those from the spray-dried blood diets, indicating that fresh, defibrinated bovine blood can successfully replace the dry blood in the screwworm rearing medium.

  9. Household Chemical Emergencies

    MedlinePlus

    ... ammonia, may react, ignite or explode. Never use hair spray, cleaning solutions, paint products, or pesticides near an open flame Clean up any chemical spill immediately. Allow the fumes in the rags ...

  10. The spray-drying process is sufficient to inactivate infectious porcine epidemic diarrhea virus in plasma.

    PubMed

    Gerber, Priscilla F; Xiao, Chao-Ting; Chen, Qi; Zhang, Jianqiang; Halbur, Patrick G; Opriessnig, Tanja

    2014-11-07

    Porcine epidemic diarrhea virus (PEDV) is considered an emergent pathogen associated with high economic losses in many pig rearing areas. Recently it has been suggested that PEDV could be transmitted to naïve pig populations through inclusion of spray-dried porcine plasma (SDPP) into the nursery diet which led to a ban of SDPP in several areas in North America and Europe. To determine the effect of spray-drying on PEDV infectivity, 3-week-old pigs were intragastrically inoculated with (1) raw porcine plasma spiked with PEDV (RAW-PEDV-CONTROL), (2) porcine plasma spiked with PEDV and then spray dried (SD-PEDV-CONTROL), (3) raw plasma from PEDV infected pigs (RAW-SICK), (4) spray-dried plasma from PEDV infected pigs (SD-SICK), or (5) spray-dried plasma from PEDV negative pigs (SD-NEG-CONTROL). For the spray-drying process, a tabletop spray-dryer with industry-like settings for inlet and outlet temperatures was used. In the RAW-PEDV-CONTROL group, PEDV RNA was present in feces at day post infection (dpi) 3 and the pigs seroconverted by dpi 14. In contrast, PEDV RNA in feces was not detected in any of the pigs in the other groups including the SD-PEDV-CONTROL group and none of the pigs had seroconverted by termination of the project at dpi 28. This work provides direct evidence that the experimental spray-drying process used in this study was effective in inactivating infectious PEDV in the plasma. Additionally, plasma collected from PEDV infected pigs at peak disease did not contain infectious PEDV. These findings suggest that the risk for PEDV transmission through commercially produced SDPP is minimal. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. 10 CFR 431.262 - Definitions concerning commercial prerinse spray valves.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 3 2012-01-01 2012-01-01 false Definitions concerning commercial prerinse spray valves. 431.262 Section 431.262 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR... (or class thereof) manufactured by one manufacturer, having the same primary energy source, and which...

  12. 10 CFR 431.262 - Definitions concerning commercial prerinse spray valves.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 3 2014-01-01 2014-01-01 false Definitions concerning commercial prerinse spray valves. 431.262 Section 431.262 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR... (or class thereof) manufactured by one manufacturer, having the same primary energy source, and which...

  13. 10 CFR 431.262 - Definitions concerning commercial prerinse spray valves.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 3 2013-01-01 2013-01-01 false Definitions concerning commercial prerinse spray valves. 431.262 Section 431.262 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR... (or class thereof) manufactured by one manufacturer, having the same primary energy source, and which...

  14. Fungicide resistance profiles for 13 Botrytis cinerea isolated from strawberry in southeastern Louisiana

    USDA-ARS?s Scientific Manuscript database

    BACKGROUND: Fungicidal sprays have been widely used for disease control of gray mold caused by Botrytis cinerea. In recent years strawberry growers in southeastern Louisiana reported a failure of their fungicide spray programs to control Botrytis fruit rot. Botrytis cinerea has become resistant ...

  15. Environmental Assessment for the Space Based Infrared System (SBIRS) Mission Control Station for Defense Support Program Consolidation

    DTIC Science & Technology

    1996-04-01

    use of products containing hazardous materials (e.g., cleaning products , spray and liquid solvents, toner cartridges, etc.). The total quantity of...products containing hazardous materials (e.g., cleaning products , spray and liquid solvents, toner cartridges, etc.). The total quantity of hazardous

  16. Evaluation of spray droplet spectrum of sprayers used for vector control

    USDA-ARS?s Scientific Manuscript database

    Droplet spectra data were collected from spray equipment intended for use in vector control by the US Department of Defense pest management programs to determine if they produce droplets in the ultra-low volume (ULV) spectrum. Droplets generated by 26 sprayers utilizing water + non-ionic surfactant...

  17. Naloxone Nasal Spray

    MedlinePlus

    ... emergency medical treatment to reverse the life-threatening effects of a known or suspected opiate (narcotic) overdose. ... called opiate antagonists. It works by blocking the effects of opiates to relieve dangerous symptoms caused by ...

  18. Comparative measurements using different particle size instruments

    NASA Technical Reports Server (NTRS)

    Chigier, N.

    1984-01-01

    This paper discusses the measurement and comparison of particle size and velocity measurements in sprays. The general nature of sprays and the development of standard, consistent research sprays are described. The instruments considered in this paper are: pulsed laser photography, holography, television, and cinematography; laser anemometry and interferometry using visibility, peak amplitude, and intensity ratioing; and laser diffraction. Calibration is by graticule, reticle, powders with known size distributions in liquid cells, monosize sprays, and, eventually, standard sprays. Statistical analyses including spatial and temporal long-time averaging as well as high-frequency response time histories with conditional sampling are examined. Previous attempts at comparing instruments, the making of simultaneous or consecutive measurements with similar types and different types of imaging, interferometric, and diffraction instruments are reviewed. A program of calibration and experiments for comparing and assessing different instruments is presented.

  19. Indoor household residual spraying program performance in Matabeleland South province, Zimbabwe: 2011 to 2012; a descriptive cross-sectional study.

    PubMed

    Chimberengwa, Pugie Tawanda; Masuka, Nyasha; Gombe, Notion Tafara; Tshimanga, Mufuta; Takundwa, Lucia; Bangure, Donewell

    2015-01-01

    Matabeleland South launched the malaria pre-elimination campaign in 2012 but provincial spraying coverage has failed to attain 95% target, with some districts still encountering malaria outbreaks. A study was conducted to evaluate program performance against achieving malaria pre-elimination. A descriptive cross sectional study was done in 5 districts carrying out IRS using the logical framework involving inputs, process, outputs and outcome evaluation. Health workers recruited into the study included direct program implementers, district and provincial program managers. An interviewer administered questionnaire, checklists, key informant interviewer guide and desk review of records were used to collect data. We enrolled 37 primary respondents and 5 key informants. Pre-elimination, Epidemic Preparedness and Response plans were absent in all districts. Shortages of inputs were reported by 97% of respondents, with districts receiving 80% of requested budget. Insecticides were procured centrally at national level. Spraying started late and districts failed to spray all targeted households by end of December. The province is using makeshift camps with inappropriate evaporation ponds where liquid DDT waste is not safely accounted for. The provincial IHRS coverage for 2011 was 84%. Challenges cited included; food shortages for spraymen, late delivery of inputs and poor state of IHRS equipment. The province has failed to achieve Malaria pre-elimination IRS coverage targets for 2011/12 season. Financial and logistical challenges led to delays in supply of program inputs, recruitment and training of sprayers. The Province should establish camping infrastructure with standard evaporation ponds to minimise contamination of the environment.

  20. Development of a Convergent Spray Technologies(tm) Spray Process for a Solventless Sprayable Coating, MCC-1

    NASA Technical Reports Server (NTRS)

    Patel, Anil K.; Meeks, C.

    1998-01-01

    This paper discusses the application of Convergent Spray Technologies (TM) Spray Process to the development and successful implementation of Marshall Convergent Coating (MCC-1) as a primary Thermal Protection System (TPS) for the Space Shuttle Solid Rocket Boosters (SRBs). This paper discusses the environmental and process benefits of the MCC-1 technology, shows the systematic steps taken in developing the technology, including statistical sensitivity studies of about 35 variables. Based on the process and post-flight successes on the SRB, it will be seen that the technology is "field-proven". Application of this technology to other aerospace and commercial programs is summarized to illustrate the wide range of possibilities.

  1. Comparative Programs for Arthropod, Disease and Weed Management in New York Organic Apples

    PubMed Central

    Agnello, Arthur; Cox, Kerik; Lordan, Jaume; Francescatto, Poliana; Robinson, Terence

    2017-01-01

    Organic apple production in the eastern US is small and is mostly based on existing varieties, which are susceptible to scab, and rootstocks, which are susceptible to fire blight. This requires numerous sprays per year of various pesticides to produce acceptable fruit. From 2014 to 2016, we tested different arthropod, disease and weed management programs in an advanced tall spindle high-density production system that included disease-resistant cultivars and rootstocks, in an organic research planting of apples in Geneva, New York. Arthropod and disease management regimens were characterized as Advanced Organic, Minimal Organic, or Untreated Control. Results varied by year and variety, but, in general, the Advanced program was more effective than the Minimal program in preventing damage from internal-feeding Lepidoptera, plum curculio, and obliquebanded leafroller, and less effective than the Minimal program against damage by foliar insects. Both organic programs provided comparable control of sooty blotch, cedar apple rust, and fire blight, with some variability across cultivars and years. The advanced selection CC1009 and Modi seemed to possess complete resistance to cedar apple rust, while Pristine had partial resistance. For weed control, bark chip mulch, organic soap sprays, and limonene sprays tended to be most effective, while mechanical tillage and flame weeding had lower success. PMID:28869562

  2. VARIABLE RATE APPLICATION OF SOIL HERBICIDES IN ARABLE CROPS: FROM THEORY TO PRACTICE.

    PubMed

    Heijting, S; Kempenaar, C

    2014-01-01

    Soil herbicides are applied around crop emergence and kill germinating weeds in the surface layer of the soil. These herbicides play an important role in the chemical management of weeds in major arable crops. From an environmental point of view there is a clear need for smarter application of these chemicals. This paper presents research done in The Netherlands on Variable Rate Application (VRA) of soil herbicides by taking into account spatial variation of the soil. Herbicides adsorbed to soil parameters such as clay or organic matter are not available for herbicidal activity. Decision Support Rules (DSR) describe the relation between the soil parameter and herbicide dosage needed for effectively controlling weeds. Research methods such as greenhouse trials, models and on farm research to develop DSR are discussed and results are presented. Another important ingredient for VRA of soil herbicides is an accurate soil map of the field. Sampling and subsequent interpolation is costly. Soil scans measuring a proxy that is subsequently translated into soil properties such as clay fraction and soil organic matter content offer a quicker way to achieve such maps but validation is needed. DSR is applied to the soil map to get the variable dosage map. The farmer combines this map with the routing, spray volume and spray boom width in the Farm Management Information System (FMIS), resulting in a task file. This task file can subsequently be read by the board computer resulting in a VRA spray map. Reduction in soil herbicide depends on the DSR, the spatial variation and pattern of the soil, the spatial configuration of the routing and the technical advances of the spray equipment. Recently, within the framework the Programma Precisie Landbouw, first steps were made to test and implement this in practice. Currently, theory and practice of VRA of soil herbicides is developed within the research program IJKakker in close cooperation with pioneering farmers in The Netherlands.

  3. Liquid Feedstock Plasma Spraying: An Emerging Process for Advanced Thermal Barrier Coatings

    NASA Astrophysics Data System (ADS)

    Markocsan, Nicolaie; Gupta, Mohit; Joshi, Shrikant; Nylén, Per; Li, Xin-Hai; Wigren, Jan

    2017-08-01

    Liquid feedstock plasma spraying (LFPS) involves deposition of ultrafine droplets of suspensions or solution precursors (typically ranging from nano- to submicron size) and permits production of coatings with unique microstructures that are promising for advanced thermal barrier coating (TBC) applications. This paper reviews the recent progress arising from efforts devoted to development of high-performance TBCs using the LFPS approach. Advancements in both suspension plasma spraying and solution precursor plasma spraying, which constitute the two main variants of LFPS, are presented. Results illustrating the different types of the microstructures that can be realized in LFPS through appropriate process parameter control, model-assisted assessment of influence of coating defects on thermo-mechanical properties and the complex interplay between pore coarsening, sintering and crystallite growth in governing thermal conductivity are summarized. The enhancement in functional performances/lifetime possible in LFPS TBCs with multilayered architectures and by incorporating new pyrochlore chemistries such as gadolinium zirconate, besides the conventional single 8 wt.% yttria-stabilized zirconia insulating ceramic layer, is specifically highlighted.

  4. [Selectivity of Beauveria bassiana and Metarhizium anisopliae to Trichogramma pretiosum Riley (Hymenoptera: Trichogrammatidae)].

    PubMed

    Potrich, Michele; Alves, Luis F A; Haas, Jucelaine; Da Silva, Everton R L; Daros, Alaxsandra; Pietrowski, Vanda; Neves, Pedro M O J

    2009-01-01

    Trichogramma pretiosum Riley and the entomopathogenic fungi Beauveria bassiana and Metarhizium anisopliae are efficient biological control agents and are thought to be used jointly. In here, we investigated if these entomopathogens could have any side-effects on T. pretiosum. Therefore, 1 x 8 cards containing sterilized eggs of Anagasta kuehniella (Zeller) that were sprayed with 0.2 ml of B. bassiana or M. anisopliae (1.0 x 10(9) conidia/ml) were offered to a T. pretiosum female for 24h (30 cards/fungus = 30 replicates). Afterwards, females were isolated in glass tubes. The control group was sprayed with sterile distillated water + Tween 80 (0.01%). In addition, 60 cards with sterilized eggs of A. kuehniella were submitted to parasitism by females of T. pretiosum for 24h. Of these cards, 30 were sprayed with B. bassiana or M. anisopliae and 30 with distillated water + Tween 80 (0.01%), and observed daily until parasitoid emergence. Metarhizium anisopliae decreased parasitoid emergence and caused confirmed mortality. Therefore, field and semi-field experiments should be conducted for a final assessment of the side-effects of these entomopathogens on Trichogramma as a ways to develop a control strategy in which both can be used.

  5. Application of reliability-centered-maintenance to BWR ECCS motor operator valve performance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Feltus, M.A.; Choi, Y.A.

    1993-01-01

    This paper describes the application of reliability-centered maintenance (RCM) methods to plant probabilistic risk assessment (PRA) and safety analyses for four boiling water reactor emergency core cooling systems (ECCSs): (1) high-pressure coolant injection (HPCI); (2) reactor core isolation cooling (RCIC); (3) residual heat removal (RHR); and (4) core spray systems. Reliability-centered maintenance is a system function-based technique for improving a preventive maintenance program that is applied on a component basis. Those components that truly affect plant function are identified, and maintenance tasks are focused on preventing their failures. The RCM evaluation establishes the relevant criteria that preserve system function somore » that an RCM-focused approach can be flexible and dynamic.« less

  6. How Much Does Malaria Vector Control Quality Matter: The Epidemiological Impact of Holed Nets and Inadequate Indoor Residual Spraying

    PubMed Central

    Rehman, Andrea M.; Coleman, Mike; Schwabe, Christopher; Baltazar, Giovanna; Matias, Abrahan; Roncon Gomes, Irina; Yellott, Lee; Aragon, Cynthia; Nseng Nchama, Gloria; Mzilahowa, Themba; Rowland, Mark; Kleinschmidt, Immo

    2011-01-01

    Background Insecticide treated nets (ITN) and indoor residual spraying (IRS) are the two pillars of malaria vector control in Africa, but both interventions are beset by quality and coverage concerns. Data from three control programs were used to investigate the impact of: 1) the physical deterioration of ITNs, and 2) inadequate IRS spray coverage, on their respective protective effectiveness. Methods Malaria indicator surveys were carried out in 2009 and 2010 in Bioko Island, mainland Equatorial Guinea and Malawi to monitor infection with P.falciparum in children, mosquito net use, net condition and spray status of houses. Nets were classified by their condition. The association between infection and quality and coverage of interventions was investigated. Results There was reduced odds of infection with P.falciparum in children sleeping under ITNs that were intact (Odds ratio (OR): 0.65, 95% CI: 0.55–0.77 and OR: 0.81, 95% CI: 0.56–1.18 in Equatorial Guinea and in Malawi respectively), but the protective effect became less with increasingly worse condition of the net. There was evidence for a linear trend in infection per category increase in deterioration of nets. In Equatorial Guinea IRS offered protection to those in sprayed and unsprayed houses alike when neighbourhood spray coverage was high (≥80%) compared to those living in areas of low IRS coverage (<20%), regardless of whether the house they lived in was sprayed or not (adjusted OR = 0.54, 95% CI 0.33–0.89). ITNs provided only personal protection, offering no protection to non users. Although similar effects were seen in Malawi, the evidence was much weaker than in Equatorial Guinea. Conclusions Universal coverage strategies should consider policies for repair and replacement of holed nets and promote the care of nets by their owners. IRS programs should ensure high spray coverage since inadequate coverage gives little or no protection at all. PMID:21559436

  7. DEMONSTRATION OF A PAINT SPRAY BOOTH EMISSION CONTROL STRATEGY USING RECIRCULATION/PARTITIONING & UV/OZONE POLLUTION EMISSION CONTROL - VOLUME 1. TECHNICAL REPORT

    EPA Science Inventory

    The report describes in detail the source testing, construction, and data reduction/analysis activities that comprise the three phases of a technology demonstration program. Phase I consisted of a detailed baseline evaluation of several paint spray booths operated at the Barstow,...

  8. Advanced Environmental Barrier Coating Development for SiC-SiC Ceramic Matrix Composite Components

    NASA Technical Reports Server (NTRS)

    Zhu, Dongming; Harder, Bryan; Hurst, Janet B.; Halbig, Michael Charles; Puleo, Bernadette J.; Costa, Gustavo; Mccue, Terry R.

    2017-01-01

    This presentation reviews the NASA advanced environmental barrier coating (EBC) system development for SiC-SiC Ceramic Matrix Composite (CMC) combustors particularly under the NASA Environmentally Responsible Aviation, Fundamental Aeronautics and Transformative Aeronautics Concepts Programs. The emphases have been placed on the current design challenges of the 2700-3000F capable environmental barrier coatings for low NOX emission combustors for next generation turbine engines by using advanced plasma spray based processes, and the coating processing and integration with SiC-SiC CMCs and component systems. The developments also have included candidate coating composition system designs, degradation mechanisms, performance evaluation and down-selects; the processing optimizations using TriplexPro Air Plasma Spray Low Pressure Plasma Spray (LPPS), Plasma Spray Physical Vapor Deposition and demonstration of EBC-CMC systems. This presentation also highlights the EBC-CMC system temperature capability and durability improvements under the NASA development programs, as demonstrated in the simulated engine high heat flux, combustion environments, in conjunction with high heat flux, mechanical creep and fatigue loading testing conditions.

  9. Spray drift reduction under Southern European conditions: a pilot study in the Ecopest Project in Greece.

    PubMed

    Kasiotis, Konstantinos M; Glass, C Richard; Tsakirakis, Angelos N; Machera, Kyriaki

    2014-05-01

    The objective of this work was to generate spray drift data from pesticide application in the field comparing spray drift from traditional equipment with emerging, anti-drift technologies. The applications were carried out in the Kopais area in central Greece. Currently few data exist as regards to pesticide spray drift in Southern European conditions. This work details the data for ground and airborne deposition of spray drift using the methodology developed in the UK by the Food and Environment Research Agency (FERA). Three trials were performed in two days using sunset yellow dye which deposited on dosimeters placed at specific distances from the edge of the sprayer boom. The application was carried out with a tractor mounted boom sprayer, which was of local manufacture, as were the nozzles of Trial I, being flat fan brass nozzles. For Trials II and III anti-drift nozzles were used. The boom sprayers were used with the settings as employed by the farmers for the routine pesticide applications. The results of this work indicate that drift was significantly reduced when anti-drift nozzles were utilized. Copyright © 2014 Elsevier B.V. All rights reserved.

  10. Spray-congealed microparticles for drug delivery - an overview of factors influencing their production and characteristics.

    PubMed

    Oh, Ching Mien; Guo, Qiyun; Wan Sia Heng, Paul; Chan, Lai Wah

    2014-07-01

    In any manufacturing process, the success of producing an end product with the desired properties and yield depends on a range of factors that include the equipment, process and formulation variables. It is the interest of manufacturers and researchers to understand each manufacturing process better and ascertain the effects of various manufacturing-associated factors on the properties of the end product. Unless the manufacturing process is well understood, it would be difficult to set realistic limits for the process variables and raw material specifications to ensure consistently high-quality and reproducible end products. Over the years, spray congealing has been used to produce particulates by the food and pharmaceutical industries. The latter have used this technology to develop specialized drug delivery systems. In this review, basic principles as well as advantages and disadvantages of the spray congealing process will be covered. Recent developments in spray congealing equipment, process variables and formulation variables such as the matrix material, encapsulated material and additives will also be discussed. Innovative equipment designs and formulations for spray congealing have emerged. Judicious choice of atomizers, polymers and additives is the key to achieve the desired properties of the microparticles for drug delivery.

  11. Application of reliability-centered maintenance to boiling water reactor emergency core cooling systems fault-tree analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Choi, Y.A.; Feltus, M.A.

    1995-07-01

    Reliability-centered maintenance (RCM) methods are applied to boiling water reactor plant-specific emergency core cooling system probabilistic risk assessment (PRA) fault trees. The RCM is a technique that is system function-based, for improving a preventive maintenance (PM) program, which is applied on a component basis. Many PM programs are based on time-directed maintenance tasks, while RCM methods focus on component condition-directed maintenance tasks. Stroke time test data for motor-operated valves (MOVs) are used to address three aspects concerning RCM: (a) to determine if MOV stroke time testing was useful as a condition-directed PM task; (b) to determine and compare the plant-specificmore » MOV failure data from a broad RCM philosophy time period compared with a PM period and, also, compared with generic industry MOV failure data; and (c) to determine the effects and impact of the plant-specific MOV failure data on core damage frequency (CDF) and system unavailabilities for these emergency systems. The MOV stroke time test data from four emergency core cooling systems [i.e., high-pressure coolant injection (HPCI), reactor core isolation cooling (RCIC), low-pressure core spray (LPCS), and residual heat removal/low-pressure coolant injection (RHR/LPCI)] were gathered from Philadelphia Electric Company`s Peach Bottom Atomic Power Station Units 2 and 3 between 1980 and 1992. The analyses showed that MOV stroke time testing was not a predictor for eminent failure and should be considered as a go/no-go test. The failure data from the broad RCM philosophy showed an improvement compared with the PM-period failure rates in the emergency core cooling system MOVs. Also, the plant-specific MOV failure rates for both maintenance philosophies were shown to be lower than the generic industry estimates.« less

  12. Current implications of past DDT indoor spraying in Oman.

    PubMed

    Booij, Petra; Holoubek, Ivan; Klánová, Jana; Kohoutek, Jiří; Dvorská, Alice; Magulová, Katarína; Al-Zadjali, Said; Čupr, Pavel

    2016-04-15

    In Oman, DDT was sprayed indoors during an intensive malaria eradication program between 1976 and 1992. DDT can remain for years after spraying and is associated with potential health risk. This raises the concern for human exposure in areas where DDT was used for indoor spraying. Twelve houses in three regions with a different history of DDT indoor spraying were chosen for a sampling campaign in 2005 to determine p,p'-dichlorodiphenyltrichloroethane (p,p'-DDT), p,p'-dichlorodiphenyldichloroethylene (p,p'-DDE) and p,p'-dichlorodiphenyldichloroethane (p,p'-DDD) levels in indoor air, dust, and outdoor soil. Although DDT was only sprayed indoor, p,p'-DDT, p,p'-DDE and p,p'-DDD were also found in outdoor soil. The results indicate that release and exposure continue for years after cessation of spraying. The predicted cancer risk based on concentrations determined in 2005, indicate that there was still a significant cancer risk up to 13 to 16years after indoor DDT spraying. A novel approach, based on region-specific half-lives, was used to predict concentrations in 2015 and showed that more than 21years after spraying, cancer risk for exposure to indoor air, dust, and outdoor soil are acceptable in Oman for adults and young children. The model can be used for other locations and countries to predict prospective exposure of contaminants based on indoor experimental measurements and knowledge about the spraying time-schedule to extrapolate region-specific half-lives and predict effects on the human population years after spraying. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. About the Drift Reduction Technology Program

    EPA Pesticide Factsheets

    The new voluntary Drift Reduction Technology (DRT) Program will encourage the manufacture, marketing, and use of safer spray technology and equipment scientifically verified to reduce pesticide drift.

  14. In situ assessment of pesticide genotoxicity in an integrated pest management program I--Tradescantia micronucleus assay.

    PubMed

    Rodrigues, G S; Pimentel, D; Weinstein, L H

    1998-02-13

    The genotoxicity induced by pesticides applied in an integrated pest management (IPM) program was evaluated with the Tradescantia micronucleus assay (Trad-MCN). Three pesticide application rates were prescribed as follows: (a) Low, no field pesticide spray; (b) Medium, IPM test rate: banded cyanazine plus metolachlor (2.7 kg a.i. and 2.3 l a.i./ha of herbicides, respectively); and (c) High, a preventative pesticide application program: broadcast cyanazine plus metolachlor (same application rates as above) plus chlorpyrifos (1 kg a.i./ha of insecticide). The Trad-MCN was employed for the assessment of (a) the formulated compounds, singly and in combinations; (b) pesticide residues extracted from soils sampled before and after application, and (c) in situ exposures (14-h exposure to pesticide-sprayed field). All pesticides showed clastogenic potency at doses between 10 and 50 ppm. Aqueous extracts of the two pesticide-sprayed soils were clastogenic, but the unsprayed soil extracts were not. Plants exposed in situ to pesticide-sprayed soils (inside a chamber receiving vapors from the soil) also showed significant increases in micronuclei frequency in relation to controls exposed to unsprayed soil. In general, there was no significant reduction in the genotoxic effects from the High to the Medium treatment levels of the IPM program. This suggests that the reduction in pesticide application rates attained with the implementation of the proposed IPM program was not sufficient to abate the genotoxicity of the pesticides, as perceived with the sensitive assays employed. The results indicate that replacing genotoxic compounds may be the only effective remediation measure to eliminate the risks imposed by mutagenic compounds in the agricultural environment.

  15. Optical monitoring systems for thermal spray processes: droplets behavior and substrate pre-treatments

    NASA Astrophysics Data System (ADS)

    Kawaguchi, Y.; Kobayashi, N.; Yamagata, Y.; Miyazaki, F.; Yamasaki, M.; Tanaka, J.; Muraoka, K.

    2017-11-01

    Thermal spray is a technique to form molten droplets using either plasma- or combustion-heating, which impinge upon substrates to form coating layers for various purposes, such as anti-corrosion and anti-wear layers. Although it is an established technique having a history of more than a century, operations of spray guns together with preparing suitable substrate surfaces for obtaining good coating layers still rely on experienced technicians. Because of the necessity of meeting more and more stringent requirements for coating quality and cost from customers, there has been a strong need to try to monitor spray processes, so as to obtain the best possible spray coating layers. The basic requirements for such monitoring systems are *reasonably cheap, *easy operation for laypersons, *easy access to targets to be investigated, and *an in-situ capability. The purpose of the present work is to provide suitable optical monitoring systems for (1) droplets behavior and (2) substrate pre-treatments. For the former (1), the first result was already presented at the 17th laser-aided plasma diagnostics meeting (LAPD17) in 2015 in Sapporo, and the results of its subsequent applications into real spray environments are shown in this article in order to validate the previous proposal. Topic (2) is new in the research program, and the proof-of-principle experiment for the proposed method yielded a favorable result. Based on this positive result, an overall strategy is being planned to fulfill the final objective of the optical monitoring of substrate pre-treatments. Details of these two programs (1) and (2) together with the present status are described.

  16. Effectiveness of agricultural oils alongside fungicides in the late dormant treatment for suppression of peach scab in Georgia, 2016

    USDA-ARS?s Scientific Manuscript database

    The efficacy of different fungicide applications for control of peach scab was tested on cv Flameprince. The fungicidal applications were applied with an airblast sprayer with a spray volume of 100 gal/A. Control treatment regimens included a non-treated control, a standard fungicidal spray program ...

  17. Erosion of polyurethane insulation.

    NASA Technical Reports Server (NTRS)

    Kraus, S.

    1973-01-01

    Detailed description of the test program in which erosion of the spray foam insulation used in the S-II stage of the Saturn-V Apollo launch vehicle was investigated. The behavior of the spray foam was investigated at the elevated temperature and static pressure appropriate to the S-II stage environment, but in the absence of the aerodynamic shear stress.

  18. Aircraft surface coatings study: Energy efficient transport program. [sprayed and adhesive bonded coatings for drag reduction

    NASA Technical Reports Server (NTRS)

    1979-01-01

    Surface coating materials for application on transport type aircraft to reduce drag, were investigated. The investigation included two basic types of materials: spray on coatings and adhesively bonded films. A cost/benefits analysis was performed, and recommendations were made for future work toward the application of this technology.

  19. An Interactive Excel Program for Tracking a Single Droplet in Crossflow Computation

    NASA Technical Reports Server (NTRS)

    Urip, E.; Yang, S. L.; Marek, C. J.

    2002-01-01

    Spray jet in crossflow has been a subject of research because of its wide application in systems involving pollutant dispersion, jet mixing in the dilution zone of combustors, and fuel injection strategies. The focus of this work is to investigate dispersion of a 2-dimensional atomized spray jet into a 2-dimensional crossflow. A quick computational method is developed using available software. The spreadsheet can be used for any 2D droplet trajectory problem where the drop is injected into the free stream eventually coming to the free stream conditions. During the transverse injection of a spray into high velocity airflow, the droplets (carried along and deflected by a gaseous stream of co-flowing air) are subjected to forces that affect their motion in the flow field. Based on the Newton's Second Law of motion, four ordinary differential equations were used. These equations were then solved by a fourth-order Runge-Kutta method using Excel software. Visual basic programming and Excel macrocode to produce the data facilitate Excel software to plot graphs describing the droplet's motion in the flow field. This program computes and plots the data sequentially without forcing users to open other types of plotting programs. A user's manual on how to use the program is also included in this report.

  20. Thermal barrier coating life-prediction model development

    NASA Technical Reports Server (NTRS)

    Strangman, T. E.; Neumann, J.; Liu, A.

    1986-01-01

    The program focuses on predicting the lives of two types of strain-tolerant and oxidation-resistant thermal barrier coating (TBC) systems that are produced by commercial coating suppliers to the gas turbine industry. The plasma-sprayed TBC system, composed of a low-pressure plasma-spray (LPPS) or an argon shrouded plasma-spray (ASPS) applied oxidation resistant NiCrAlY or (CoNiCrAlY) bond coating and an air-plasma-sprayed yttria partially stabilized zirconia insulative layer, is applied by both Chromalloy, Klock, and Union Carbide. The second type of TBS is applied by the electron beam-physical vapor deposition (EB-PVD) process by Temescal. The second year of the program was focused on specimen procurement, TMC system characterization, nondestructive evaluation methods, life prediction model development, and TFE731 engine testing of thermal barrier coated blades. Materials testing is approaching completion. Thermomechanical characterization of the TBC systems, with toughness, and spalling strain tests, was completed. Thermochemical testing is approximately two-thirds complete. Preliminary materials life models for the bond coating oxidation and zirconia sintering failure modes were developed. Integration of these life models with airfoil component analysis methods is in progress. Testing of high pressure turbine blades coated with the program TBS systems is in progress in a TFE731 turbofan engine. Eddy current technology feasibility was established with respect to nondestructively measuring zirconia layer thickness of a TBC system.

  1. 40 CFR 265.32 - Required equipment.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... equipment, or automatic sprinklers, or water spray systems. ... of equipment specified below: (a) An internal communications or alarm system capable of providing... assistance from local police departments, fire departments, or State or local emergency response teams; (c...

  2. 40 CFR 265.32 - Required equipment.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... equipment, or automatic sprinklers, or water spray systems. ... of equipment specified below: (a) An internal communications or alarm system capable of providing... assistance from local police departments, fire departments, or State or local emergency response teams; (c...

  3. 40 CFR 265.32 - Required equipment.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... equipment, or automatic sprinklers, or water spray systems. ... of equipment specified below: (a) An internal communications or alarm system capable of providing... assistance from local police departments, fire departments, or State or local emergency response teams; (c...

  4. 40 CFR 265.32 - Required equipment.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... equipment, or automatic sprinklers, or water spray systems. ... of equipment specified below: (a) An internal communications or alarm system capable of providing... assistance from local police departments, fire departments, or State or local emergency response teams; (c...

  5. 40 CFR 265.32 - Required equipment.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... equipment, or automatic sprinklers, or water spray systems. ... of equipment specified below: (a) An internal communications or alarm system capable of providing... assistance from local police departments, fire departments, or State or local emergency response teams; (c...

  6. Fatal hypersensitivity reaction to an oral spray of flurbiprofen: a case report.

    PubMed

    Calapai, G; Imbesi, S; Cafeo, V; Ventura Spagnolo, E; Minciullo, P L; Caputi, A P; Gangemi, S; Milone, L

    2013-08-01

    Safety of the anti-inflammatory drug flurbiprofen is comparable with that of other non-steroidal anti-inflammatory drugs of the propionic acid class, which are commonly associated with gastrointestinal and renal side effects. Here we report a case of a fatal hypersensitivity reaction to an oral spray of flurbiprofen taken for sore throat. A 29-year-old man came to the emergency care unit reporting sore throat with an intense burning sensation associated with fever. Pharyngotonsillitis was diagnosed, and local treatment with oral flurbiprofen spray was prescribed. Immediately after using the spray, the patient experienced a severe reaction characterized by serious dyspnoea, followed by death. The cause of death was heart failure with acute asphyxia from oedema of the glottis. The cause of death was concluded to be hypersensitivity to flurbiprofen spray. Oral propionic acid derivatives have been associated with a relatively high frequency of allergic reactions. However, allergy to flurbiprofen has rarely been documented. Scientific literature reports two relevant cases of hypersensitivity reaction to flurbiprofen: in one case, a patient presented with a maculopapular rash 48 h after having taken oral flurbiprofen followed by angio-oedema and hypotension. In another case, a single oral dose of flurbiprofen caused itching and swelling around the eyes, redness and increased lacrimation. We describe, for the first time, a fatal case of hypersensitivity reaction to flurbiprofen oral spray. Hypersensitivity reactions to flurbiprofen are infrequent; however, health professionals should be aware of potential adverse reactions, even during topical administration as oral spray. © 2013 John Wiley & Sons Ltd.

  7. Description of Liquid Nitrogen Experimental Test Facility

    NASA Technical Reports Server (NTRS)

    Jurns, John M.; Jacobs, Richard E.; Saiyed, Naseem H.

    1991-01-01

    The Liquid Nitrogen Test Facility is a unique test facility for ground-based liquid nitrogen experimentation. The test rig consists of an insulated tank of approximately 12.5 cubic ft in volume, which is supplied with liquid nitrogen from a 300 gal dewar via a vacuum jacketed piping system. The test tank is fitted with pressure and temperature measuring instrumentation, and with two view ports which allow visual observation of test conditions. To demonstrate the capabilities of the facility, the initial test program is briefly described. The objective of the test program is to measure the condensation rate by injecting liquid nitrogen as a subcooled spray into the ullage of a tank 50 percent full of liquid nitrogen at saturated conditions. The condensation rate of the nitrogen vapor on the subcooled spray can be analytically modeled, and results validated and corrected by experimentally measuring the vapor condensation on liquid sprays.

  8. Description of liquid nitrogen experimental test facility

    NASA Technical Reports Server (NTRS)

    Jurns, J. M.; Jacobs, R. E.; Saiyed, N. H.

    1992-01-01

    The Liquid Nitrogen Test Facility is a unique test facility for ground-based liquid nitrogen experimentation. The test rig consists of an insulated tank of approximately 12.5 cubic ft in volume, which is supplied with liquid nitrogen from a 300 gal dewar via a vacuum jacketed piping system. The test tank is fitted with pressure and temperature measuring instrumentation, and with two view ports which allow visual observation of test conditions. To demonstrate the capabilities of the facility, the initial test program is briefly described. The objective of the test program is to measure the condensation rate by injecting liquid nitrogen as a subcooled spray into the ullage of a tank 50 percent full of liquid nitrogen at saturated conditions. The condensation rate of the nitrogen vapor on the subcooled spray can be analytically modeled, and results validated and corrected by experimentally measuring the vapor condensation on liquid sprays.

  9. Promoting species establishment in a phragmites-dominated great lakes coastal wetland

    USGS Publications Warehouse

    Carlson, M.L.; Kowalski, K.P.; Wilcox, D.A.

    2009-01-01

    This study examined efforts to promote species establishment and maintain diversity in a Phragmites-dominated wetland where primary control measures were underway. A treatment experiment was performed at Crane Creek, a drowned-river-mouth wetland in Ottawa National Wildlife Refuge along the shore of western Lake Erie. Following initial aerial spraying of Phragmites with glyphosate, this study tested combinations of cutting, raking, and additional hand spraying of Phragmites with glyphosate as methods to promote growth of other wetland species and increase plant diversity. Percent-cover vegetation data were collected in permanent plots before and after treatments, and follow-up sampling was performed the following year. Increased species richness, species emergence, and relative dominance of non-Phragmites taxa were used as measures of treatment success. We also examined treatment effects on Phragmites cover. Dimensionality of seedbank and soil properties was reduced using principal component analysis. With the exception of nitrogen, soil nutrients affected species establishment, non-Phragmites taxa dominance, and Phragmites cover. A more viable seedbank led to greater species emergence. Treatments had differential effects on diversity depending on elevation and resulting degree of hydrologic inundation. Whereas raking to remove dead Phragmites biomass was central to promoting species establishment in dry areas, spraying had a greater impact in continually inundated areas. For treatment success across elevations into the year following treatments, spraying in combination with cutting and raking had the greatest effect. The results of this study suggest that secondary treatments can produce a short-term benefit to the plant community in areas treated for Phragmites.

  10. Delayed efficacy of Beauveria bassiana foliar spray applications against Colorado potato beetle: impacts of number and timing of applications on larval and next-generation adult populations

    USDA-ARS?s Scientific Manuscript database

    Spray programs comprising multiple or single foliar applications of the fungal pathogen Beauveria bassiana strain GHA (Bb) made during morning (AM) vs. evening (PM) hours were tested against Colorado potato beetle Leptinotarsa decemlineata (CPB) in small research plots of potatoes over multiple fiel...

  11. Thermal barrier coating life-prediction model development

    NASA Technical Reports Server (NTRS)

    Strangman, T. E.; Neumann, J.

    1985-01-01

    Life predictions are made for two types of strain-tolerant and oxidation-resistant Thermal Barrier Coating (TBC) systems produced by commercial coating suppliers to the gas turbine industry. The plasma-sprayed TBC system, composed of a low-pressure plasma spray (LPPS) applied oxidation-resistant NiCrAlY bond coating and an air-plasma-sprayed yttria (8 percent) partially stabilized zirconia insulative layer, is applied by both Chromalloy and Klock. The second type of TBC is applied by the electron-beam/physical vapor deposition process by Temescal. Thermomechanical and thermochemical testing of the program TBCs is in progress. A number of the former tests has been completed. Fracture mechanics data for the Chromalloy plasma-sprayed TBC system indicate that the cohesive toughness of the zirconia layer is increased by thermal cycling and reduced by high temperature exposure at 1150 C. Eddy current technology feasibility has been established with respect to nondestructively measuring zirconia layer thickness of a TBC system. High pressure turbine blades have been coated with program TBC systems for a piggyback test in a TFE731-5 turbofan factory engine test. Data from this test will be used to validate the TBC life models.

  12. Development and Testing of a Mobile Platform for Tank Remediation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nance, T.A.

    2001-01-16

    The Department of Energy (DOE) is committed to removing millions of gallons of high level radioactive waste from waste storage tanks at the Savannah River Site (SRS). SRS was the first site in the DOE complex to have emptied and closed high level waste tanks. Tank closure at the Site is now progressing to tanks containing waste composed of liquid and large deposits of solids, including a tank that has a potential ''heel''. A heel is a hardened mass of solid waste material spread across the tank bottom. Tank closure requires breaking up this heel and moving the material tomore » the intake of a pumping system for transfer from the tank. In the past, overhead spray systems have been used with some success at moving waste. But the limited number of risers restricts the coverage area of the overhead spray system. Therefore, a floor- level spray system will be used to separate manageable size chunks of the material from the heel. The chunks will be guided into the pump's intake to be remove from the tank. The floor-level spray system movement will be accomplished by using a mobile platform, a crawler, which provides transport to nearly every point on the tank floor. Transport of the spray system will allow the system to ''corral'' the waste away from the tank walls and control the movement of the material across the tank floor. Because the available access riser is small, and a wide crawler platform is required to support the spray system, the crawler's frame must fold to enter the tank. After entry into the tank, the crawler unfolds on the tank floor using the crawler drive tracks to expand the frame and position the mobile platform under the entry riser. The spray system will then be lowered separately through the entry riser and mated onto the crawler on the tank floor. The crawler and spray system are tethered and controlled remotely by personnel at the control station. Motorized cable reels will also be remotely controlled to pay out, retrieve, and manage the tethers as the mobile platform moves the spray system across the tank floor. Both the crawler and spray systems are designed to be retrievable. Development of the tank cleaning system was evaluated using a performance test program. The tests evaluated the spray system dynamics, the crawler's fit through the riser, the crawler landing in mocked up tank with simulant, the crawler's traction, and the crawler and spray system mating. Initial testing verified the crawler platform was compatible with the dynamics produced by the spray system. The riser fit test confirmed that a dedicated riser is required for deployment of the crawler and the spray system. The crawler traction test defined the capabilities of the crawler at different levels of simulant. Deployment testing through a mockup riser verified the basic system processes. Finally, testing of the complete system in a full-scale mockup with sludge simulant was performed to evaluate the tank cleaning ability of the crawler. This paper describes th e tank conditions, the tank closure process, the development of the crawler and spray system, and the testing program and results used to evaluate the mobile platform and spray system.« less

  13. Thermal barrier coating life-prediction model development. Annual report no. 2

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Strangman, T. E.; Neumann, J.; Liu, A.

    1986-10-01

    The program focuses on predicting the lives of two types of strain-tolerant and oxidation-resistant thermal barrier coating (TBC) systems that are produced by commercial coating suppliers to the gas turbine industry. The plasma-sprayed TBC system, composed of a low-pressure plasma-spray (LPPS) or an argon shrouded plasma-spray (ASPS) applied oxidation resistant NiCrAlY or (CoNiCrAlY) bond coating and an air-plasma-sprayed yttria partially stabilized zirconia insulative layer, is applied by both Chromalloy, Klock, and Union Carbide. The second type of TBS is applied by the electron beam-physical vapor deposition (EB-PVD) process by Temescal. The second year of the program was focused on specimenmore » procurement, TMC system characterization, nondestructive evaluation methods, life prediction model development, and TFE731 engine testing of thermal barrier coated blades. Materials testing is approaching completion. Thermomechanical characterization of the TBC systems, with toughness, and spalling strain tests, was completed. Thermochemical testing is approximately two-thirds complete. Preliminary materials life models for the bond coating oxidation and zirconia sintering failure modes were developed. Integration of these life models with airfoil component analysis methods is in progress. Testing of high pressure turbine blades coated with the program TBS systems is in progress in a TFE731 turbofan engine. Eddy current technology feasibility was established with respect to nondestructively measuring zirconia layer thickness of a TBC system.« less

  14. Droplet Sizing Research Program.

    DTIC Science & Technology

    1986-03-10

    of size and velocity distributions is needed. For example, fuel spray studies, aer- osol studies, flue gas desulfurization , spray drying, paint...techniques are presented chronologic- ally since there is a logical development as a function of time. Most of the significant technical accomplishments...U3U 0 0 ILI N signals with an apparently different size by using the following logic : droplets that produce a certain visibility are associated with a

  15. Application of External Axis in Robot-Assisted Thermal Spraying

    NASA Astrophysics Data System (ADS)

    Deng, Sihao; Fang, Dandan; Cai, Zhenhua; Liao, Hanlin; Montavon, Ghislain

    2012-12-01

    Currently, industrial robots are widely used in the process of thermal spraying because of their high efficiency, security, and repeatability. Although robots are found suitable for use in industrial productions, they have some natural disadvantages because of their six-axis mechanical linkages. When a robot performs a series of stages of production, it could be hard to move from one to another because a few axes reach their limit value. For this reason, an external axis should be added to the robot system to extend the reachable space of the robots. This article concerns the application of external axis on ABB robots in thermal spraying and the different methods of off-line programming with external axis in the virtual environment. The developed software toolkit was applied to coat real workpiece with a complex geometry in atmospheric plasma spraying).

  16. Effect of calcium sprays on mechanical strength and cell wall fractions of herbaceous peony (Paeonia lactiflora pall.) inflorescence stems.

    PubMed

    Li, Chengzhong; Tao, Jun; Zhao, Daqiu; You, Chao; Ge, Jintao

    2012-01-01

    Calcium is an essential element and imparts significant structural rigidity to the plant cell walls, which provide the main mechanical support to the entire plant. In order to increase the mechanical strength of the inflorescence stems of herbaceous peony, the stems are treated with calcium chloride. The results shows that preharvest sprays with 4% (w/v) calcium chloride three times after bud emergence are the best at strengthening "Da Fugui" peonies' stems. Calcium sprays increased the concentrations of endogenous calcium, total pectin content as well as cell wall fractions in herbaceous peonies stems, and significantly increased the contents of them in the top segment. Correlation analysis showed that the breaking force of the top segment of peonies' stems was positively correlated with the ratio of water insoluble pectin to water soluble pectin (R = 0.673) as well as lignin contents (R = 0.926) after calcium applications.

  17. Oleoresin capsicum (Cap-Stun) toxicity from aerosol exposure.

    PubMed

    Watson, W A; Stremel, K R; Westdorp, E J

    1996-01-01

    To describe the clinical toxicity caused by oleoresin capsicum (OC) spray during law-enforcement action. A medical record review. Emergency department (ED), Truman Medical Center, Kansas City, MO. Consecutive patients who presented to the ED after OC-spray exposure from law-enforcement action between June 1991 and June 1994. Patient presentation and symptoms at presentation, evaluation, and treatment during ED stay. Eighty-one ED patients, approximately 10% of all individuals sprayed by police officers, presented after exposure to OC. Ocular burning and redness were the most common presenting symptoms. None of the patients required hospitalization due to OC toxicity. Corneal abrasions and respiratory symptoms occurred in 7 and 6 patients, respectively. The need for ED evaluation and treatment was infrequent after exposure to OC. A transient burning sensation, erythema, and localized irritation were the most common findings. While no patients had adverse outcomes attributed to OC exposure, practitioners assessing exposure should consider the potential for pulmonary and ocular toxicity.

  18. Manufacturing of composite titanium-titanium nitride coatings by reactive very low pressure plasma spraying (R-VLPPS)

    NASA Astrophysics Data System (ADS)

    Vautherin, B.; Planche, M.-P.; Quet, A.; Bianchi, L.; Montavon, G.

    2014-11-01

    Very Low Pressure Plasma Spraying (VLPPS) is an emerging spray process nowadays intensively studied by many research centers in the World. To date, studies are mostly focused on the manufacturing of ceramic or metallic coatings. None refers to composite coatings manufacturing by reactive plasma spraying under very low pressure (i.e., ~150 Pa). This paper aims at presenting the carried-out developments and some results concerning the manufacturing of composite coatings by reactive spraying. Titanium was selected as metallic material in order to deposit titanium-nitride titanium coatings (Ti-TiN). Nitrogen was used as plasma gas and was injected along an Ar-H2-N2 plasma jet via a secondary injector in order to reach the nitrogen content on the substrate surface. Thus, different kind of reactive mechanisms were highlighted. Resulting coatings were characterized by Scanning Electron Microscopy (SEM) observations. Porous microstructures are clearly identified and the deposits exhibit condensed vapours and molten particles. Glow Discharge Optical Emission Spectroscopy (GDOES) analysis evidenced nitrogen inside the deposits and X-Ray Diffraction (XRD) analysis confirmed the formation of titanium nitride phases, such as TiN and Ti2N, depending upon the location of the nitrogen injection. Microhardness values as high as 800 VHN were measured on manufactured samples (to be compared to 220 VHN for pure titanium VLPPS-manufactured coatings).

  19. A deep look into the spray coating process in real-time—the crucial role of x-rays

    NASA Astrophysics Data System (ADS)

    Roth, Stephan V.

    2016-10-01

    Tailoring functional thin films and coating by rapid solvent-based processes is the basis for the fabrication of large scale high-end applications in nanotechnology. Due to solvent loss of the solution or dispersion inherent in the installation of functional thin films and multilayers the spraying and drying processes are strongly governed by non-equilibrium kinetics, often passing through transient states, until the final structure is installed. Therefore, the challenge is to observe the structural build-up during these coating processes in a spatially and time-resolved manner on multiple time and length scales, from the nanostructure to macroscopic length scales. During installation, the interaction of solid-fluid interfaces and between the different layers, the flow and evaporation themselves determine the structure of the coating. Advanced x-ray scattering methods open a powerful pathway for observing the involved processes in situ, from the spray to the coating, and allow for gaining deep insight in the nanostructuring processes. This review first provides an overview over these rapidly evolving methods, with main focus on functional coatings, organic photovoltaics and organic electronics. Secondly the role and decisive advantage of x-rays is outlined. Thirdly, focusing on spray deposition as a rapidly emerging method, recent advances in investigations of spray deposition of functional materials and devices via advanced x-ray scattering methods are presented.

  20. The electrospray: Fundamentals and combustion applications

    NASA Technical Reports Server (NTRS)

    Gomez, Alessandro

    1993-01-01

    Liquid fuel dispersion in practical systems is typically achieved by spraying the fuel into a polydisperse distribution of droplets evaporating and burning in a turbulent gaseous environment. In view of the nearly unsurmountable difficulties of this two-phase flow, it would be useful to use an experimental arrangement that allow a systematic study of spray evolution and burning in configurations of gradually increasing levels of complexity, starting from laminar sprays to fully turbulent ones. An Electrostatic Spray (ES) of charged droplets lends itself to this type of combustion experiments under well-defined conditions and can be used to synthesize gradually more complex spray environments. In its simplest configuration, a liquid is fed into a small metal tube maintained at several kilovolts relative to a ground electrode few centimeters away. Under the action of the electric field, the liquid meniscus at the outlet of the capillary takes a conical shape, with a thin jet emerging from the cone tip. This jet breaks up farther downstream into a fine spray of charged droplets. Several advantages distinguish the electrospray from alternative atomization techniques: the self-dispersion property of the spray due to coulombic repulsion; the absence of droplet coalescence; the potential control of the trajectories of charged droplets by suitable disposition of electrostatic fields; and the decoupling of atomization, which is strictly electrostatic, from gas flow processes. Furthermore, as recently shown in our laboratory, the electrospray can produce quasi-monodisperse droplets over a very broad size range (1-100 microns). The ultimate objective of this research project is to study the formation and burning of electrosprays of liquid fuels first in laminar regimes and then in turbulent ones. Combustion will eventually be investigated in conditions of three-dimensional droplet-droplet interaction, for which experimental studies have been limited to either qualitative observations in sprays or more quantitative observations on simplified systems consisting of a small number of droplets or droplet arrays. The compactness and potential controllability of this spray generaiton system makes it appealing for studies to be undertaken in the next two years on electrospray combustion in reduced-gravity environments such as those achievable at NASA microgravity test facilities.

  1. A Meta-Analysis of Studies of Treatments for Feline Urine Spraying

    PubMed Central

    Mills, Daniel S.; Redgate, Sarah E.; Landsberg, Gary M.

    2011-01-01

    Feline urine spraying inside the home is a common problem behaviour that owners seek advice for from veterinarians. Individual trials relating to a variety of interventions produce variable results, and to date, no consensus on the value of different treatments has emerged. This study therefore aimed to meta-analyse, current data from appropriate published clinical trials that evaluate treatments for feline urine spraying. Inclusion and exclusion criteria for study selection were predefined and methodological quality was assessed by two independent reviewers. Ten studies in nine publications that either evaluated pharmacotherapy or pheromonatherapy (the use of a synthetic analogue of the F3 facial fraction in the cat) were suitable for analysis. There was a significant (P<0.001) association between the use of any intervention and the number of cats that ceased or reduced urine spraying by at least 90%. Analysis by intervention type indicated that fluoxetine, clomipramine and pheromonatherapy may each assist in managing urine spraying beyond a placebo based intervention. This is the first time meta-analytical techniques have been used and reported to evaluate the efficacy of interventions used in veterinary behavioural medicine, and it has established confidence in the value of both conventional treatments (pharmacotherapy) and a more recently developed treatment modality (pheromonatherapy) as an adjunct to the management of this problem. It is suggested that future research into treatment efficacy for this problem uses the benchmark standard of randomised, controlled trials lasting for at least 8 weeks, with the outcome criteria of cessation of feline urine spraying or reduction by at least 90%. PMID:21525994

  2. Heat, Mass and Aerosol Transfers in Spray Conditions for Containment Application

    NASA Astrophysics Data System (ADS)

    Porcheron, Emmanuel; Lemaitre, Pascal; Nuboer, Amandine; Vendel, Jacques

    TOSQAN is an experimental program undertaken by the Institut de Radioprotection et de Surété Nucleaire (IRSN) in order to perform thermal hydraulic containment studies. The TOSQAN facility is a large enclosure devoted to simulating typical accidental thermal hydraulic flow conditions in nuclear Pressurized Water Reactor (PWR) containment. The TOSQAN facility, which is highly instrumented with non-intrusive optical diagnostics, is particularly adapted to nuclear safety CFD code validation. The present work is devoted to studying the interaction of a water spray injection used as a mitigation means in order to reduce the gas pressure and temperature in the containment, to produce gases mixing and washout of fission products. In order to have a better understanding of heat and mass transfers between spray droplets and the gas mixture, and to analyze mixing effects due to spray activation, we performed detailed characterization of the two-phase flow.

  3. Cotton harvest at 40% versus 75% boll-splitting on yield and economic return under standard and proactive boll weevil (Coleoptera: Curculionidae) spray regimes.

    PubMed

    Showler, A T; Robinson, J R C

    2008-10-01

    The standard practice of two or three preemptive insecticide applications at the start of pinhead (1-2-mm-diameter) squaring followed by threshold-triggered (when 10% of randomly selected squares have oviposition punctures) insecticide applications for boll weevil, Anthonomus grandis grandis Boheman (Coleoptera: Curculionidae), control does not provide reliable protection of cotton, Gossypium hirsutum L., lint production. This study, conducted during 2004 and 2005, showed that three to six fewer spray applications in a "proactive" approach, in which spraying began at the start of large (5.5-8-mm-diameter) square formation and continued at approximately 7-d intervals while large squares were abundant, resulted in fewer infested squares and 1.4- to 1.7-fold more lint than the standard treatment. Fewer sprays and increased yield made proactive spraying significantly more profitable than the standard approach, which resulted in relatively low or negative economic returns. Harvest at 75% boll-split in the proactive spray regime of 2005 resulted in four-fold greater economic return than cotton harvested at 40% boll-split because of improved protection of large squares and the elimination of late-season sprays inherent to standard spray regime despite the cost of an extra irrigation in the 75% boll-split treatments. The earlier, 40% harvest trigger does not avoid high late-season boll weevil pressure, which exerts less impact on bolls, the predominant form of fruiting body at that time, than on squares. Proactive spraying and harvest timing are based on an important relationship between nutrition, boll weevil reproduction, and economic inputs; therefore, the tactic of combining proaction with harvest at 75% boll-split is applicable where boll weevils are problematic regardless of climate or region, or whether an eradication program is ongoing.

  4. Technology Insertion (TI)/Industrial Process Improvement (IPI) Task Order Number 15, Data Base Documentation Book SA-ALC/MAE & MAT

    DTIC Science & Technology

    1990-12-14

    r . ,,,’ , ,.r ,-z /Ar A i-, ’- -. q <-->- as 7/ 4, ’C ’ 4’ / de /- --, AI c " (/’r)i -l 74 7 C/L CAe 71C, eX X-- r , ’Ie? 74-4 c- 7,’/,, , /’ 74 V1;he...GLASSES SAFETY GOGGLES CHEMICAL SPLASH GOGGLES &rFACE SHIELD RESPIRATOR ORGANIC VAPOR SPRAY PAINT METAL FUME I TOXIC ,._ ____r _ _ _ OTHER (Speci’y...SAFETY GOGGLES CHEMICAL SPLASH GOGGLES - , FACE SHIELD RESPIRATOR ORGANIC VAPOR SPRAY PAINT METAL FUME ’ TOXIC DUST OTHER (Specify) 23. EMERGENCY

  5. Cold spray NDE for porosity and other process anomalies

    NASA Astrophysics Data System (ADS)

    Glass, S. W.; Larche, M. R.; Prowant, M. S.; Suter, J. D.; Lareau, J. P.; Jiang, X.; Ross, K. A.

    2018-04-01

    This paper describes a technology review of nondestructive evaluation (NDE) methods that can be applied to cold spray coatings. Cold spray is a process for depositing metal powder at high velocity so that it bonds to the substrate metal without significant heating that would be likely to cause additional residual tensile stresses. Coatings in the range from millimeters to centimeters are possible at relatively high deposition rates. Cold spray coatings that may be used for hydroelectric components that are subject to erosion, corrosion, wear, and cavitation damage are of interest. The topic of cold spray NDE is treated generally, however, but may be considered applicable to virtually any cold spray application except where there are constraints of the hydroelectric component application that bear special consideration. Optical profilometry, eddy current, ultrasound, and hardness tests are shown for one set of good, fair, and poor nickel-chrome (NiCr) on 304 stainless steel (304SS) cold spray samples to demonstrate inspection possibilities. The primary indicator of cold spray quality is the cold spray porosity that is most directly measured with witness-sample destructive examinations (DE)—mostly photo-micrographs. These DE-generated porosity values are correlated with optical profilometry, eddy current, ultrasound, and hardness test NDE methods to infer the porosity and other information of interest. These parameters of interest primarily include: • Porosity primarily caused by improper process conditions (temperature, gas velocity, spray standoff, spray angle, powder size, condition, surface cleanliness, surface oxide, etc.) • Presence/absence of the cold spray coating including possible over-sprayed voids • Coating thicknessOptical profilometry measurements of surface roughness trended with porosity plus, if compared with a reference measurement or reference drawing, would provide information on the coating thickness. Ultrasound could provide similar surface profile information plus attenuation measurements trended with porosity. The ultrasound measurements, however, may be limited to geometries where the substrate back-wall is normal to the cold spray surface and not too thick. Eddy current showed a strong correlation with porosity. Eddy currents can also be sensitive to cracks and do not need fluid coupling to make measurements, but are not sensitive to coating thicknesses in most cases. Vickers hardness measurements also tracked well with porosity; however, these types of hardness measurements are also not sensitive to coating thickness. An NDE program may include multiple measurements.

  6. Development of a new low cost antireflective coating technique for solar cells

    NASA Technical Reports Server (NTRS)

    Wohlgemuth, J. H.; Warfield, D. B.; Johnson, G. A.

    1982-01-01

    The goal of this study was the development of an antireflective (AR) coating technique that has the potential for high throughput and low cost yet is capable of producing films of good optical quality. Previous efforts to develop sprayed AR coatings had utilized titanium isopropoxide mixed with volatile solvents. These films worked well on smooth surfaces but when applied to etched semi-crystalline silicon surfaces yielded inconsistent results with more than 20 percent of the AM1 incident light being reflected. In this program titanium isopropoxide was sprayed directly onto heater wafers (410 C) to produce a uniform AR coating even on highly textured surfaces. Tests on various types of solar cells yielded performance improvements for the hot sprayed AR cells that are equivalent to that observed for evaporated TiOx AR coated cells. As an extension of this effort a new double layer AR consisting of a bottom layer of hot sprayed titanium isopropoxide and a top layer of hot sprayed aluminum isopropoxide in methylene chloride has resulted in more than 10 percent improvement in cell output as compared to a single layer AR cell.

  7. Impact of soil type, moisture, and depth on swede midge (Diptera: Cecidomyiidae) pupation and emergence.

    PubMed

    Chen, Mao; Shelton, Anthony M

    2007-12-01

    Contarinia nasturtii (Kieffer) (Diptera: Cecidomyiidae), a common insect pest in Europe and a new invasive pest in North America, causes severe damage to cruciferous crops. Currently, many counties in Canada and the United States in which C. nasturtii has not been previously reported are at risk of being infested by C. nasturtii. Effectiveness of chemical control is limited, especially under high population pressure in fields, because the cryptic habits of C. nasturtii protect them from insecticidal sprays. Alternative management strategies against C. nasturtii that are needed to protect crucifers and soil management for the pupal stage were studied as one option. Six different types of soils (loam fine sand, fine sand, clay loam, muck, Chenango shale loam, and silt loam soil) were collected from commercial cabbage fields in New York and studied in the laboratory for their impact on C. nasturtii pupation and emergence. The results indicated that extremely wet or dry soils significantly hindered C. nasturtii emergence, regardless of soil type, suggesting that soil type alone may not be a major factor regulating C. nasturtii abundance. Optimal moisture content for C. nasturtii emergence varied for different soils. Most C. nasturtii pupated within the top 1 cm of soil. Furthermore, we found that >5 cm of soil cover effectively reduced the emergence number and delayed the time of emergence. Based on these results, we suggest that soil manipulation (moisture content and cultivation practices) should be considered as an important component in an overall integrated pest management program for C. nasturtii.

  8. Equal Opportunity, Equal Work: Increasing Women's Participation in the U.S. President's Malaria Initiative Africa Indoor Residual Spraying Project

    PubMed Central

    Donner, Abigail; Belemvire, Allison; Johns, Ben; Mangam, Keith; Fiekowsky, Elana; Gunn, Jayleen; Hayden, Mary; Ernst, Kacey

    2017-01-01

    Background: One of the primary control measures for malaria transmission is indoor residual spraying (IRS). Historically, few women have worked in IRS programs, despite the income-generating potential. Increasing women's roles in IRS requires understanding the barriers to women's participation and implementing measures to address them. The U.S. President's Malaria Initiative (PMI) Africa Indoor Residual Spraying (AIRS) Project is the largest implementer of IRS globally. To address gender inequity in IRS operations, PMI AIRS assessed the barriers to the participation of women and developed and implemented policies to address these barriers. Methods: The PMI AIRS Project initially identified barriers through a series of informal assessments with key stakeholders. PMI AIRS then implemented a series of gender-guided policies, starting in 2015, in Benin, Ethiopia, Ghana, Mali, Madagascar, Mozambique, Rwanda, Senegal, Zambia, and Zimbabwe. The policies included adapting physical work environments to ensure privacy for women; ensuring the safety of women in the workplace; guaranteeing safety and job security of women during pregnancy; and encouraging qualified women to apply for supervisory positions. The project collected routine programmatic data on staff, spray quality, and spray efficiency; data from 2012 through the end of 2015 were analyzed (up through 1 year after implementation of the gender policies). In addition, PMI AIRS conducted surveys in 2015, 2016, and 2017 before and after the spray campaigns in 4 countries to determine changes in gender norms among spray operators through questions about decision making and agency. Results: The PMI AIRS Project increased women's employment with the program. Specifically, women's employment increased overall from 23% in 2012 to 29% in 2015, with a 2015 range from 16% (Mali) to 40% (Madagascar). Growth among supervisor roles was even stronger, with the percentage of women in supervisory roles increasing from 17% in 2012 to 46% in 2015, with a 2015 range from 9% (Mali) to 50% (Madagascar). While the data showed that in most countries women sprayed fewer houses per day than men in 2015, the differences were not meaningful, ranging from 0.1 to 1.2 households per day. Gender norms shifted toward more egalitarian views in 2 of the 4 countries with survey data. Conclusion: Preliminary results suggest the PMI AIRS Project gender policies are increasing the engagement of women in all aspects of spray operations, especially in supervisory roles. Expansion of these policies to all countries implementing IRS and to malaria control implementation more broadly is recommended. PMID:29242251

  9. Equal Opportunity, Equal Work: Increasing Women's Participation in the U.S. President's Malaria Initiative Africa Indoor Residual Spraying Project.

    PubMed

    Donner, Abigail; Belemvire, Allison; Johns, Ben; Mangam, Keith; Fiekowsky, Elana; Gunn, Jayleen; Hayden, Mary; Ernst, Kacey

    2017-12-28

    One of the primary control measures for malaria transmission is indoor residual spraying (IRS). Historically, few women have worked in IRS programs, despite the income-generating potential. Increasing women's roles in IRS requires understanding the barriers to women's participation and implementing measures to address them. The U.S. President's Malaria Initiative (PMI) Africa Indoor Residual Spraying (AIRS) Project is the largest implementer of IRS globally. To address gender inequity in IRS operations, PMI AIRS assessed the barriers to the participation of women and developed and implemented policies to address these barriers. The PMI AIRS Project initially identified barriers through a series of informal assessments with key stakeholders. PMI AIRS then implemented a series of gender-guided policies, starting in 2015, in Benin, Ethiopia, Ghana, Mali, Madagascar, Mozambique, Rwanda, Senegal, Zambia, and Zimbabwe. The policies included adapting physical work environments to ensure privacy for women; ensuring the safety of women in the workplace; guaranteeing safety and job security of women during pregnancy; and encouraging qualified women to apply for supervisory positions. The project collected routine programmatic data on staff, spray quality, and spray efficiency; data from 2012 through the end of 2015 were analyzed (up through 1 year after implementation of the gender policies). In addition, PMI AIRS conducted surveys in 2015, 2016, and 2017 before and after the spray campaigns in 4 countries to determine changes in gender norms among spray operators through questions about decision making and agency. The PMI AIRS Project increased women's employment with the program. Specifically, women's employment increased overall from 23% in 2012 to 29% in 2015, with a 2015 range from 16% (Mali) to 40% (Madagascar). Growth among supervisor roles was even stronger, with the percentage of women in supervisory roles increasing from 17% in 2012 to 46% in 2015, with a 2015 range from 9% (Mali) to 50% (Madagascar). While the data showed that in most countries women sprayed fewer houses per day than men in 2015, the differences were not meaningful, ranging from 0.1 to 1.2 households per day. Gender norms shifted toward more egalitarian views in 2 of the 4 countries with survey data. Preliminary results suggest the PMI AIRS Project gender policies are increasing the engagement of women in all aspects of spray operations, especially in supervisory roles. Expansion of these policies to all countries implementing IRS and to malaria control implementation more broadly is recommended. © Donner et al.

  10. Multi-country assessment of residual bio-efficacy of insecticides used for indoor residual spraying in malaria control on different surface types: results from program monitoring in 17 PMI/USAID-supported IRS countries.

    PubMed

    Dengela, Dereje; Seyoum, Aklilu; Lucas, Bradford; Johns, Benjamin; George, Kristen; Belemvire, Allison; Caranci, Angela; Norris, Laura C; Fornadel, Christen M

    2018-01-30

    Indoor residual spraying (IRS) is the application of insecticide to the interior walls of household structures that often serve as resting sites for mosquito vectors of malaria. Human exposure to malaria vectors is reduced when IRS involves proper application of pre-determined concentrations of the active ingredient specific to the insecticide formulation of choice. The impact of IRS can be affected by the dosage of insecticide, spray coverage, vector behavior, vector susceptibility to insecticides, and the residual efficacy of the insecticide applied. This report compiles data on the residual efficacy of insecticides used in IRS campaigns implemented by the United States President's Malaria Initiative (PMI)/United States Agency for International Development (USAID) in 17 African countries and compares observed length of efficacy to ranges proposed in World Health Organization (WHO) guidelines. Additionally, this study provides initial analysis on variation of mosquito mortality depending on the surface material of sprayed structures, country spray program, year of implementation, source of tested mosquitoes, and type of insecticide. Residual efficacy of the insecticides used for PMI/USAID-supported IRS campaigns was measured in Benin, Burkina Faso, Ethiopia, Ghana, Kenya, Liberia, Madagascar, Malawi, Mali, Mozambique, Nigeria, Rwanda, Senegal, Tanzania, Uganda, Zambia and Zimbabwe. The WHO cone bioassay tests were used to assess the mortality rate of mosquitoes exposed to insecticide-treated mud, wood, cement, and other commonly used housing materials. Baseline tests were performed within weeks of IRS application and follow-up tests were continued until the mortality of exposed mosquitoes dropped below 80% or the program monitoring period ended. Residual efficacy in months was then evaluated with respect to WHO guidelines that provide suggested ranges of residual efficacy for insecticide formulations recommended for use in IRS. Where the data allowed, direct comparisons of mosquito mortality rates were then made to determine any significant differences when comparing insecticide formulation, country, year, surface type, and the source of the mosquitoes used in testing. The residual efficacy of alpha-cypermethrin ranged from 4 to 10 months (average = 6.4 months), with no reported incidents of underperformance when compared to the efficacy range provided in WHO guidelines. Deltamethrin residual efficacy results reported a range of 1 to 10 months (average = 4.9 months), with two instances of underperformance. The residual efficacy of bendiocarb ranged from 2 weeks to 7 months (average = 2.8 months) and failed to achieve proposed minimum efficacy on 14 occasions. Lastly, long-lasting pirimiphos-methyl efficacy ranged from 2 months to 9 months (average = 5.3 months), but reported 13 incidents of underperformance. Much of the data used to determine application rate and expected efficacy of insecticides approved for use in IRS programs are collected in controlled laboratory or pilot field studies. However, the generalizability of the results obtained under controlled conditions are limited and unlikely to account for variation in locally sourced housing materials, climate, and the myriad other factors that may influence the bio-efficacy of insecticides. Here, data are presented that confirm the variation in residual efficacy observed when monitoring household surfaces sprayed during PMI/USAID-supported IRS campaigns. All insecticides except alpha-cypermethrin showed evidence of failing to meet the minimum range of residual efficacy proposed in WHO criteria at least once. However, this initial effort in characterizing program-wide insecticide bio-efficacy indicates that some insecticides, such as bendiocarb and pirimiphos-methyl, may be vulnerable to variations in the local environment. Additionally, the comparative analysis performed in this study provides evidence that mosquito mortality rates differ with respect to factors including: the types of insecticide sprayed, surface material, geographical location, year of spraying, and tested mosquitoes. It is, therefore, important to locally assess the residual efficacy of insecticides on various surfaces to inform IRS programming.

  11. Flame structure of wall-impinging diesel fuel sprays injected by group-hole nozzles

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gao, Jian; Moon, Seoksu; Nishida, Keiya

    This paper describes an investigation of the flame structure of wall-impinging diesel sprays injected by group-hole nozzles in a constant-volume combustion vessel at experimental conditions typical of a diesel engine. The particular emphasis was on the effect of the included angle between two orifices (0-15 deg. in current study) on the flame structure and combustion characteristics under various simulated engine load conditions. The laser absorption scattering (LAS) technique was applied to analyze the spray and mixture properties. Direct flame imaging and OH chemiluminescence imaging were utilized to quantify the ignition delay, flame geometrical parameters, and OH chemiluminescence intensity. The imagesmore » show that the asymmetric flame structure emerges in wall-impinging group-hole nozzle sprays as larger included angle and higher engine load conditions are applied, which is consistent with the spray shape observed by LAS. Compared to the base nozzle, group-hole nozzles with large included angles yield higher overall OH chemiluminescence intensity, wider flame area, and greater proportion of high OH intensity, implying the better fuel/air mixing and improved combustion characteristics. The advantages of group-hole nozzle are more pronounced under high load conditions. Based on the results, the feasibility of group-hole nozzle for practical direct injection diesel engines is also discussed. It is concluded that the asymmetric flame structure of a group-hole nozzle spray is favorable to reduce soot formation over wide engine loads. However, the hole configuration of the group-hole nozzle should be carefully considered so as to achieve proper air utilization in the combustion chamber. Stoichiometric diesel combustion is another promising application of group-hole nozzle. (author)« less

  12. Eco-friendly spray coating of organic solar cells through water-based nanoparticles ink (Presentation Recording)

    NASA Astrophysics Data System (ADS)

    Stryckers, Jeroen; D'Olieslaeger, Lien; Manca, Jean; Ethirajan, Anitha; Deferme, Wim

    2015-09-01

    Ultrasonic spray coating is currently proven to be a reliable, flexible and cost efficient fabrication method for printed electronics [1-2]. Ultrasonic nozzles are by design especially well-suited to deposit nano-suspension dispersions. Due to the ultrasonic vibration of the nozzle, droplets having a median diameter of 20 μm are created in a homogeneous droplet cloud and directed towards the substrate. When one prepares an ink having the right wetting properties, thin and homogeneous layers, fully covering the surface, can be achieved. Together with conjugated polymer nanoparticles (NPs), emerging as a new class of nanomaterials, [3] it opens possibilities towards eco-friendly roll-to-roll processing of state-of-the-art organic bulk heterojunction solar cells. A ultrasonic spray coater was used to print the conjugated polymer NP layers under different conditions. A first optimization of the spray coater settings (flow rate, spray speed and temperature) and the ink formulation (water and co-solvent mixture and NP content) was performed for polystyrene particles dissolved in a water-ethanol mixture. As a next step, the low bandgap donor polymer poly[9-(1-octylnonyl)-9H-carbazole-2,7-diyl]-2,5-thiophenediyl-2,1,3-benzothiadiazole-4,7-diyl-2,5-thiophene-diyl] (PCDTBT) [4] and the fullerene acceptor phenyl-C71-butyric acid methyl ester (PCBM[70]) were combined in a water-based blend NP dispersion which was prepared using the mini-emulsion technique. [5,6] Optical Microscopy, profilometry and Scanning Electron Microscopy (SEM) are performed to study the roughness, surface structure, thickness and coverage of the spray coated layers. Finally the printed NP layers are integrated in organic bulk heterojunction solar cells and compared to spin coated reference devices.

  13. AmeriFlux US-AR1 ARM USDA UNL OSU Woodward Switchgrass 1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Billesbach, Dave; Bradford, James

    This is the AmeriFlux version of the carbon flux data for the site US-AR1 ARM USDA UNL OSU Woodward Switchgrass 1. Site Description - The ARM USDA UNL OSU Woodward Switchgrass 1 tower is located on public land owned by the USDA-ARS Southern Plains Range Research Station in Woodward, Oklahoma. The site is on a former native prairie that is in the process of changing to switchgrass. A second companion site (ARM USDA UNL OSU Woodward Switchgrass 2) is on a former wheat field. In Spring 2009, the former native prairie site was burned, cattle were put on the pasturemore » to graze down emergent grass, and broadleaf herbicide was sprayed. In Summer 2009, the cattle were removed from the pasture, and the site was sprayed with herbicide to kill all grass. In Spring 2010, prior to the planting of switchgrass, final herbicide was sprayed to kill cheat grass and to control broadleaf plants.« less

  14. The use of x-ray radiography for measuring mass distributions of Rocket Injectors

    DTIC Science & Technology

    2013-06-01

    successfully applied to diesel injectors , aerated liquid jets and impinging-jet sprays [7-10]. X-ray radiography can be performed using either a...Rocket Injectors 5a. CONTRACT NUMBER N/A 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) S.A. Schumaker, A.L. Kastengren, M.D.A...measurements for injector design. Unfortunately, the mass flow rates typically encountered in rocket engines create sprays with high optical densities

  15. Evaluation of thermal sprayed metallic coatings for use on the structures at Launch Complex 39

    NASA Technical Reports Server (NTRS)

    Welch, Peter J.

    1990-01-01

    The current status of the evaluation program is presented. The objective was to evaluate the applicability of Thermal Sprayed Coatings (TSC) to protect the structures in the high temperature acid environment produced by exhaust of the Solid Rocket Boosters during the launches of the Shuttle Transportation System. Only the relatively low cost aluminum TSC which provides some cathodic protection for steel appears to be a practical candidate for further investigation.

  16. The National Shipbuilding Research Program. Application of Industrial Engineering Techniques to Reduce Workers’ Compensation and Environmental Costs - Deliverable D

    DTIC Science & Technology

    1999-10-01

    Electrostatic guns provide opportunities for exterior application of topcoats such as urethanes, acrylics , alkyds and epoxies. Most shipbuilding...A hybrid of airless spray and conventional air-atomized spray, this kind of gun uses fluid pressures higher than those used in conventional air...voltage) by simply flipping a switch. All essential controls are located right at the back of the gun. Other electrostatic systems require constant

  17. Stability relationship for water droplet crystallization with the NASA Lewis icing spray

    NASA Technical Reports Server (NTRS)

    Marek, C. John; Bartlett, C. Scott

    1987-01-01

    In order to produce small droplets for icing cloud simulation, high pressure air atomizing nozzles are used. For certain icing testing applications, median drop sizes as small as 5 mm are needed, which require air atomizing pressures greater than 3000 kPa. Isentropic expansion of the ambient temperature atomizing air to atmospheric pressure can result in air stream temperatures of -160 C which results in ice crystals forming in the cloud. To avoid such low temperatures, it is necessary to heat the air and water to high initial temperatures. An icing spray research program was conducted to map the temperatures below which ice crystals form. A soot slide technique was used to determine the presence of crystals in the spray.

  18. Biomonitoring of genotoxic risk in agricultural workers from five colombian regions: association to occupational exposure to glyphosate.

    PubMed

    Bolognesi, C; Carrasquilla, G; Volpi, S; Solomon, K R; Marshall, E J P

    2009-01-01

    In order to assess possible human effects associated with glyphosate formulations used in the Colombian aerial spray program for control of illicit crops, a cytogenetic biomonitoring study was carried out in subjects from five Colombian regions, characterized by different exposure to glyphosate and other pesticides. Women of reproductive age (137 persons 15-49 yr old) and their spouses (137 persons) were interviewed to obtain data on current health status, history, lifestyle, including past and current occupational exposure to pesticides, and factors including those known to be associated with increased frequency of micronuclei (MN). In regions where glyphosate was being sprayed, blood samples were taken prior to spraying (indicative of baseline exposure), 5 d after spraying, and 4 mo after spraying. Lymphocytes were cultured and a cytokinesis-block micronucleus cytome assay was applied to evaluate chromosomal damage and cytotoxicity. Compared with Santa Marta, where organic coffee is grown without pesticides, the baseline frequency of binucleated cells with micronuclei (BNMN) was significantly greater in subjects from the other four regions. The highest frequency of BNMN was in Boyaca, where no aerial eradication spraying of glyphosate was conducted, and in Valle del Cauca, where glyphosate was used for maturation of sugar cane. Region, gender, and older age (> or =35 yr) were the only variables associated with the frequency of BNMN measured before spraying. A significant increase in frequency of BNMN between first and second sampling was observed in Narino, Putumayo, and Valle immediately (<5 d) after spraying. In the post-spray sample, those who reported direct contact with the eradication spray showed a higher quantitative frequency of BNMN compared to those without glyphosate exposure. The increase in frequency of BNMN observed immediately after the glyphosate spraying was not consistent with the rates of application used in the regions and there was no association between self-reported direct contact with eradication sprays and frequency of BNMN. Four months after spraying, a statistically significant decrease in the mean frequency of BNMN compared with the second sampling was observed in Narino, but not in Putumayo and Valle del Cauca. Overall, data suggest that genotoxic damage associated with glyphosate spraying for control of illicit crops as evidenced by MN test is small and appears to be transient. Evidence indicates that the genotoxic risk potentially associated with exposure to glyphosate in the areas where the herbicide is applied for coca and poppy eradication is low.

  19. Emergency Cooling of Nuclear Power Plant Reactors With Heat Removal By a Forced-Draft Cooling Tower

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Murav’ev, V. P., E-mail: murval1@mail.ru

    The feasibility of heat removal during emergency cooling of a reactor by a forced-draft cooling tower with accumulation of the peak heat release in a volume of precooled water is evaluated. The advantages of a cooling tower over a spray cooling pond are demonstrated: it requires less space, consumes less material, employs shorter lines in the heat removal system, and provides considerably better protection of the environment from wetting by entrained moisture.

  20. Vision-aided Monitoring and Control of Thermal Spray, Spray Forming, and Welding Processes

    NASA Technical Reports Server (NTRS)

    Agapakis, John E.; Bolstad, Jon

    1993-01-01

    Vision is one of the most powerful forms of non-contact sensing for monitoring and control of manufacturing processes. However, processes involving an arc plasma or flame such as welding or thermal spraying pose particularly challenging problems to conventional vision sensing and processing techniques. The arc or plasma is not typically limited to a single spectral region and thus cannot be easily filtered out optically. This paper presents an innovative vision sensing system that uses intense stroboscopic illumination to overpower the arc light and produce a video image that is free of arc light or glare and dedicated image processing and analysis schemes that can enhance the video images or extract features of interest and produce quantitative process measures which can be used for process monitoring and control. Results of two SBIR programs sponsored by NASA and DOE and focusing on the application of this innovative vision sensing and processing technology to thermal spraying and welding process monitoring and control are discussed.

  1. Dramatic Decrease in Malaria Transmission after Large-Scale Indoor Residual Spraying with Bendiocarb in Benin, an Area of High Resistance of Anopheles gambiae to Pyrethroids

    PubMed Central

    Akogbeto, Martin; Padonou, Gil Germain; Bankole, Honore Sourou; Gazard, Dorothee Kinde; Gbedjissi, Ghelus Louis

    2011-01-01

    In 2008, the National Malaria Control Program in Benin implemented a vector control intervention based on indoor residual spraying (IRS). Four districts of high resistance of Anopheles gambiae to pyrethroids were sprayed with bendiocarb. More than 350,000 inhabitants have been protected. Entomologic parameters in the control area were compared with those in intervention sites. The study has shown a drastic decrease in the An. gambiae biting rate in the sprayed areas. Results of an enzyme-linked immunosorbent assay were negative for Plasmodium falciparum antigen during the entire period of the intervention. No household members received infected bites (entomologic inoculation rate = 0 during January–July). Parous rates were low in areas covered by IRS because bendiocarb is not conducive to long-term mosquito survival. Bendiocarb was found to be a good alternative insecticide for IRS in Benin, in areas where An. gambiae has developed high resistance to pyrethroids. PMID:21976555

  2. Restoring marsh elevation in a rapidly subsiding salt marsh by thin-layer deposition of dredged material

    USGS Publications Warehouse

    Ford, M.A.; Cahoon, D.R.; Lynch, J.C.

    1999-01-01

    Thin-layer deposition of dredged material on coastal marsh by means of high-pressure spray dredging (Jet-Spray??2) technology has been proposed as a mechanism to minimize wetland impacts associated with traditional bucket dredging technologies and to restore soil elevations in deteriorated marshes of the Mississippi River delta. The impact of spray dredging on vegetated marsh and adjacent shallow-water habitat (formerly vegetated marsh that deteriorated to open water) was evaluated in a 0.5-ha Spartina alterniflora-dominated salt marsh in coastal Louisiana. The thickness of dredged sediment deposits was determined from artificial soil marker horizons and soil elevation change was determined from sedimentation-erosion tables (SET) established prior to spraying in both sprayed and reference marshes. The vertical accretion and elevation change measurements were made simultaneously to allow for calculation of shallow (~5 m depth) subsidence (accretion minus elevation change). Measurements made immediately following spraying in July 1996 revealed that stems of S. alterniflora were knocked down by the force of the spray and covered with 23 mm of dredged material. Stems of S. alterniflora soon recovered, and by July 1997 the percent cover of S. alterniflora had increased three-fold over pre-project conditions. Thus, the layer of dredged material was thin enough to allow for survival of the S. alterniflora plants, with no subsequent colonization by plant species typical of higher marsh zones. By February 1998, 62 mm of vertical accretion accumulated at this site, and little indication of disturbance was noted. Although not statistically significant, soil elevation change was greater than accretion on average at both the spray and reference marshes, suggesting that subsurface expansion caused by increased root biomass production and/or pore water storage influence elevation in this marsh region. In the adjacent shallow water pond, 129 mm of sediment was deposited in July 1996 as a result of spraying, and despite initial shallow subsidence and continual erosion through February 1998, water bottom elevation was raised sufficiently to allow S. alterniflora to invade via rhizome growth from the adjacent marsh. Hence, thin-layer deposition of dredged material at this site was effective at restoring and maintaining marsh elevation after 1.5 years. However, if the open water sediment deposits are not soon completely stabilized via further vegetative colonization, erosion may eventually lower elevations to the level where emergent vegetation cannot persist.

  3. Macro controlling of copper oxide deposition processes and spray mode by using home-made fully computerized spray pyrolysis system

    NASA Astrophysics Data System (ADS)

    Essa, Mohammed Sh.; Chiad, Bahaa T.; Shafeeq, Omer Sh.

    2017-09-01

    Thin Films of Copper Oxide (CuO) absorption layer have been deposited using home-made Fully Computerized Spray Pyrolysis Deposition system FCSPD on glass substrates, at the nozzle to substrate distance equal to 20,35 cm, and computerized spray mode (continues spray, macro-control spray). The substrate temperature has been kept at 450 °c with the optional user can enter temperature tolerance values ± 5 °C. Also that fixed molar concentration of 0.1 M, and 2D platform speed or deposition platform speed of 4mm/s. more than 1000 instruction program code, and specific design of graphical user interface GUI to fully control the deposition process and real-time monitoring and controlling the deposition temperature at every 200 ms. The changing in the temperature has been recorded during deposition processes, in addition to all deposition parameters. The films have been characterized to evaluate the thermal distribution over the X, Y movable hot plate, the structure and optical energy gap, thermal and temperature distribution exhibited a good and uniform distribution over 20 cm2 hot plate area, X-ray diffraction (XRD) measurement revealed that the films are polycrystalline in nature and can be assigned to monoclinic CuO structure. Optical band gap varies from 1.5-1.66 eV depending on deposition parameter.

  4. Design and integrated operation of an innovative thermodynamic vent system concept

    NASA Astrophysics Data System (ADS)

    Fazah, Michel M.; Lak, Tibor; Nguyen, Han; Wood, Charles C.

    1993-06-01

    A unique zero-g thermodynamic vent system (TVS) is being developed by NASA's Marshall Space Flight Center (MSFC) and Rockwell International to meet cryogenic propellant management requirements for future space missions. The design is highly innovative in that it integrates the functions of a spray-bar tank mixer and a TVS. This concept not only satisfies the requirement for efficient tank mixing and zero-g venting but also accommodates thermal conditioning requirements for other components (e.g., engine feed lines, turbopumps, and liquid acquisition devices). In addition, operations can be extended to accomplish tank chill-down, no-vent fill, and emergency venting during zero-g propellant transfer. This paper describes the system performance characterization and future test activities that are part of MSFC's Multipurpose Hydrogen Test Bed (MHTB) program. The testing will demonstrate the feasibility and merit of the design, and serve as a proof-of-concept development activity.

  5. Social Support Can Buffer against Stress and Shape Brain Activity

    PubMed Central

    Hostinar, Camelia E.; Gunnar, Megan R.

    2015-01-01

    Social support from close relationship partners is an important resource for coping with stress, particularly during childhood. We discuss ethical challenges associated with studying stress and its social buffering in the laboratory, as well as emerging evidence regarding two potential neural substrates for the social buffering of stress: hypothalamic oxytocin activity and activation of areas in the prefrontal cortex associated with effective self-regulation. We also address the role of early-life social experiences in shaping brain development, as well as recommendations for practice and policy that would advance the ethical treatment of children and reduce social inequalities in early-life experiences and opportunities–e.g., investing in programs that prevent child maltreatment and facilitating access to high-quality child care for economically disadvantaged families. We also debate the ethical implications of using oxytocin nasal sprays to simulate the stress-reducing properties of social support and advise waiting for more evidence before recommending their use. PMID:26478822

  6. Process Research ON Semix Silicon Materials (PROSSM)

    NASA Astrophysics Data System (ADS)

    Wohlgemuth, J. H.; Warfield, D. B.

    1982-02-01

    A cost effective process sequence was identified, equipment was designed to implement a 6.6 MW per year automated production line, and a cost analysis projected a $0.56 per watt cell add-on cost for this line. Four process steps were developed for this program: glass beads back clean-up, hot spray antireflective coating, wave soldering of fronts, and ion milling for edging. While spray dopants were advertised as an off the shelf developed product, they were unreliable with shorter than advertised shelf life.

  7. Process Research ON Semix Silicon Materials (PROSSM)

    NASA Technical Reports Server (NTRS)

    Wohlgemuth, J. H.; Warfield, D. B.

    1982-01-01

    A cost effective process sequence was identified, equipment was designed to implement a 6.6 MW per year automated production line, and a cost analysis projected a $0.56 per watt cell add-on cost for this line. Four process steps were developed for this program: glass beads back clean-up, hot spray antireflective coating, wave soldering of fronts, and ion milling for edging. While spray dopants were advertised as an off the shelf developed product, they were unreliable with shorter than advertised shelf life.

  8. ENVIRONMENTAL TECHNOLOGY VERIFICATION COATINGS AND COATING EQUIPMENT PROGRAM (ETV CCEP) HIGH TRANSFER EFFICIENCE SPRAY EQUIPMENT--GENERIC VERIFICATION PROTOCOL

    EPA Science Inventory

    The Environmental Technology Verification (ETV) Program has been established to verify the performance characteristics of innovative environmental technologies and report this objective information, thus, accelerating the entrance of these new technologies into the marketplace. V...

  9. Development of improved-durability plasma sprayed ceramic coatings for gas turbine engines

    NASA Technical Reports Server (NTRS)

    Sumner, I. E.; Ruckle, D. L.

    1980-01-01

    As part of a NASA program to reduce fuel consumption of current commercial aircraft engines, methods were investigated for improving the durability of plasma sprayed ceramic coatings for use on vane platforms in the JT9D turbofan engine. Increased durability concepts under evaluation include use of improved strain tolerant microstructures and control of the substrate temperature during coating application. Initial burner rig tests conducted at temperatures of 1010 C (1850 F) indicate that improvements in cyclic life greater than 20:1 over previous ceramic coating systems were achieved. Three plasma sprayed coating systems applied to first stage vane platforms in the high pressure turbine were subjected to a 100-cycle JT9D engine endurance test with only minor damage occurring to the coatings.

  10. Environmental Technology Verification Coatings and Coating Equipment Program (ETV CCEP) High Transfer Efficiency Spray Equipment--Generic Verification Protocol

    EPA Science Inventory

    The Environmental Technology Verification (ETV) Program has been established by the U.S. Environmental Protection Agency (EPA) to verify the performance characteristics of innovative environmental technologies across all media and report this objective information to the states, ...

  11. Uptake of three antibiotics and an anti-epileptic drug by wheat plants spray irrigated with wastewater treatment plant effluent

    USDA-ARS?s Scientific Manuscript database

    With rising demands on water supplies necessitating water reuse, wastewater treatment plant (WWTP) effluent is often used to irrigate agricultural lands. Emerging contaminants, like pharmaceuticals and personal care products (PPCPs), are frequently found in effluent due to limited removal during WWT...

  12. Accessing inoculation methods of maize and wheat with Azospirillum brasilense.

    PubMed

    Fukami, Josiane; Nogueira, Marco Antonio; Araujo, Ricardo Silva; Hungria, Mariangela

    2016-03-01

    The utilization of inoculants containing Azospirillum is becoming more popular due to increasing reports of expressive gains in grain yields. However, incompatibility with pesticides used in seed treatments represents a main limitation for a successful inoculation. Therefore, in this study we searched for alternatives methods for seed inoculation of maize and wheat, aiming to avoid the direct contact of bacteria with pesticides. Different doses of inoculants containing Azospirillum brasilense were employed to perform inoculation in-furrow, via soil spray at sowing and via leaf spray after seedlings had emerged, in comparison to seed inoculation. Experiments were conducted first under greenhouse controlled conditions and then confirmed in the field at different locations in Brazil. In the greenhouse, most parameters measured responded positively to the largest inoculant dose used in foliar sprays, but benefits could also be observed from both in-furrow and soil spray inoculation. However, our results present evidence that field inoculation with plant-growth promoting bacteria must consider inoculant doses, and point to the need of fine adjustments to avoid crossing the threshold of growth stimulation and inhibition. All inoculation techniques increased the abundance of diazotrophic bacteria in plant tissues, and foliar spray improved colonization of leaves, while soil inoculations favored root and rhizosphere colonization. In field experiments, inoculation with A. brasilense allowed for a 25 % reduction in the need for N fertilizers. Our results have identified alternative methods of inoculation that were as effective as the standard seed inoculation that may represent an important strategy to avoid the incompatibility between inoculant bacteria and pesticides employed for seed treatment.

  13. Ecological Effects of the War in Vietnam

    ERIC Educational Resources Information Center

    Orians, Gordon H.; Pfeiffer, E. W.

    1970-01-01

    Research report on the severe ecological consequences of the defoliation program by American military forces in Vietnam. A significant fraction of mature trees in most forests are killed by single application of herbicides and almost completely killed by repeated sprayings. AAAS is urged to set up an international research program on the…

  14. Lower Urinary Tract Symptoms: What's New in Medical Treatment?

    PubMed

    Peyronnet, Benoit; Brucker, Benjamin M; Michel, Martin C

    2018-04-14

    Pharmacological treatment is a cornerstone in the management of patients with lower urinary tract symptoms (LUTS). To review emerging evidence in the medical treatment of LUTS. An Embase/Pubmed-based literature search was conducted in December 2017, screening for randomized controlled trials (RCTs), prospective and retrospective series, animal model studies, and reviews on medical treatment of LUTS. The main medical innovation in recent years in overactive bladder (OAB) has been the approval of the first β 3 -adrenoceptor agonists (mirabegron) and intradetrusor onabotulinum toxin A, while several other drugs such as antiepileptics, phosphodiesterase inhibitors, or other β 3 -agonists have brought promising results in phase 3 trials. Intraprostatic injections of various drugs for LUTS/benign prostatic hyperplasia have been investigated, but results of phase 3 trials are still pending, while combination therapies of phosphodiesterase type 5 inhibitors+α-blockers or finasteride have been proved as superior to single therapies in RCTs conducted in these patients. Two new formulations of desmopressin have been approved for nocturia in the USA (desmopressin nasal spray) and Europe/Canada/Australia (desmopressin orally disintegrated tablet). Fedovapagon, a vasopressin V 2 receptor agonist, has recently completed a large phase 3 trial in male patients with nocturia. Other phase 3 trials are ongoing in bladder pain syndrome (AQX 11-25, a SHIP-1 activator) and in neurogenic detrusor overactivity (mirabegron and abobotulinum toxin A). Medical treatment of LUTS is a very active research field with recently approved drugs for nocturia (desmopressin acetate nasal spray/orally disintegrated tablet) and numerous emerging drugs currently investigated in OAB, LUTS/benign prostatic hyperplasia, nocturia, bladder pain syndrome, and neurogenic detrusor overactivity. Medical treatment of lower urinary tract symptoms is a very active research field with recently approved drugs for nocturia (desmopressin acetate nasal spray/orally disintegrated tablet) and numerous emerging drugs in overactive bladder, nocturia, neurogenic detrusor overactivity, bladder pain syndrome, or benign prostatic hyperplasia. Copyright © 2018 European Association of Urology. Published by Elsevier B.V. All rights reserved.

  15. An experimental and theoretical investigation of deposition patterns from an agricultural airplane

    NASA Technical Reports Server (NTRS)

    Morris, D. J.; Croom, C. C.; Vandam, C. P.; Holmes, B. J.

    1984-01-01

    A flight test program has been conducted with a representative agricultural airplane to provide data for validating a computer program model which predicts aerially applied particle deposition. Test procedures and the data from this test are presented and discussed. The computer program features are summarized, and comparisons of predicted and measured particle deposition are presented. Applications of the computer program for spray pattern improvement are illustrated.

  16. Assessment of RELAP5/MOD2 against a pressurizer spray valve inadverted fully opening transient and recovery by natural circulation in Jose Cabrera Nuclear Station

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Arroyo, R.; Rebollo, L.

    1993-06-01

    This document presents the comparison between the simulation results and the plant measurements of a real event that took place in JOSE CABRERA nuclear power plant in August 30th, 1984. The event was originated by the total, continuous and inadverted opening of the pressurizer spray valve PCV-400A. JOSE CABRERA power plant is a single loop Westinghouse PWR belonging to UNION ELECTRICA FENOSA, S.A. (UNION FENOSA), an Spanish utility which participates in the International Code Assessment and Applications Program (ICAP) as a member of UNIDAD ELECTRICA, S.A. (UNESA). This is the second of its two contributions to the Program: the firstmore » one was an application case and this is an assessment one. The simulation has been performed using the RELAP5/MOD2 cycle 36.04 code, running on a CDC CYBER 180/830 computer under NOS 2.5 operating system. The main phenomena have been calculated correctly and some conclusions about the 3D characteristics of the condensation due to the spray and its simulation with a 1D tool have been got.« less

  17. Quantifying expert consensus against the existence of a secret, large-scale atmospheric spraying program

    NASA Astrophysics Data System (ADS)

    Shearer, Christine; West, Mick; Caldeira, Ken; Davis, Steven J.

    2016-08-01

    Nearly 17% of people in an international survey said they believed the existence of a secret large-scale atmospheric program (SLAP) to be true or partly true. SLAP is commonly referred to as ‘chemtrails’ or ‘covert geoengineering’, and has led to a number of websites purported to show evidence of widespread chemical spraying linked to negative impacts on human health and the environment. To address these claims, we surveyed two groups of experts—atmospheric chemists with expertize in condensation trails and geochemists working on atmospheric deposition of dust and pollution—to scientifically evaluate for the first time the claims of SLAP theorists. Results show that 76 of the 77 scientists (98.7%) that took part in this study said they had not encountered evidence of a SLAP, and that the data cited as evidence could be explained through other factors, including well-understood physics and chemistry associated with aircraft contrails and atmospheric aerosols. Our goal is not to sway those already convinced that there is a secret, large-scale spraying program—who often reject counter-evidence as further proof of their theories—but rather to establish a source of objective science that can inform public discourse.

  18. Program to develop sprayed, plastically deformable compressor shroud seal materials

    NASA Technical Reports Server (NTRS)

    Schwab, R. C.

    1979-01-01

    A study of fundamental rub behavior for ten dense sprayed materials and eight current compressor clearance materials has been conducted. A literature survey of a wide variety of metallurgical and thermophysical properties was conducted and correlated to rub behavior. Based on these results, the most promising dense rub material was Cu-9Al. Additional studies on the effects of porosity, incursion rate, blade solidity and ambient temperature were carried out on aluminum bronze (Cu-9Al-1Fe) with and without a 515B Feltmetal underlayer.

  19. Rocket injector anomalies study. Volume 1: Description of the mathematical model and solution procedure

    NASA Technical Reports Server (NTRS)

    Przekwas, A. J.; Singhal, A. K.; Tam, L. T.

    1984-01-01

    The capability of simulating three dimensional two phase reactive flows with combustion in the liquid fuelled rocket engines is demonstrated. This was accomplished by modifying an existing three dimensional computer program (REFLAN3D) with Eulerian Lagrangian approach to simulate two phase spray flow, evaporation and combustion. The modified code is referred as REFLAN3D-SPRAY. The mathematical formulation of the fluid flow, heat transfer, combustion and two phase flow interaction of the numerical solution procedure, boundary conditions and their treatment are described.

  20. [Blocking the spray of contaminants from patients' exhalent using a tracheal detecting bulb during endotracheal intubation].

    PubMed

    Tong, You-liang; Sun, Ming; Wang, Zhen; Li, Bin; Xie, Jue; Ye, Hui

    2011-11-01

    To examine the effect of a newly-developed tracheal detecting-bulb (TDB) in preventing the spray of contaminants in patients' exhalent during emergency endotracheal intubation procedure. 62 emergency patients (male or female, age 21-73 years, weight 47-83 kg, with different levels of consciousness and spontaneous breathing) were randomly divided into two groups (n =31 each) to receive endotracheal intubation by an anesthesiologist with more than 17 years of experience, with (TDB group) or without (control group) a TDB connected to the tracheal tubing. Records were taken regarding the patient's coughing, expansion / contraction of the TDB, the operator's feeling of the patient's exhalent on his face / neck and the contamination of these areas by blood / secretions from the patients in the due course. In TDB group, expansion / contraction of TDB occurred in all cases, but the operator felt no exhalent in any of them. In 9 cases the patients coughed but the operator was contaminated only in 2 cases. While in control group, the patients' exhalent was felt in 16 cases. Coughing were recorded in 7 cases, and the operator was contaminated in 11 cases. In comparison with the control group, TDB group had significantly lower(both P < 0.05), incidence in feeling the exhalent (0 vs. 16), and contamination by blood or secretions (2 vs. 11) although the two groups had no significant difference in the incidence of coughing (9 vs. 7, P > 0.05). TDB can play an important role in blocking the spray of contaminants in patients' exhalent during endotracheal intubation.

  1. Sustainable management tactics for control of Phyllotreta cruciferae (Coleoptera: Chrysomelidae) on canola in Montana.

    PubMed

    Reddy, Gadi V P; Tangtrakulwanich, Khanobporn; Miller, John H; Ophus, Victoria L; Prewett, Julie

    2014-04-01

    The crucifer flea beetle, Phyllotreta cruciferae (Goeze) (Coleoptera: Chrysomelidae), has recently emerged as a serious pest of canola (Brassica napus L.) in Montana. The adult beetles feed on canola leaves, causing many small holes that stunt growth and reduce yield. In 2013, damage to canola seedlings was high (approximately 80%) in many parts of Montana, evidence that when flea beetles emerge in large numbers, they can quickly destroy a young canola crop. In the current study, the effectiveness of several biopesticides was evaluated and compared with two insecticides (deltamethrin and bifenthrin) commonly used as foliar sprays as well as seed treatment with an imidacloprid insecticide for the control of P. cruciferae under field conditions in 2013. The biopesticides used included an entomopathogenic nematode (Steinernema carpocapsae), two entomopathogenic fungi (Beauveria bassiana and Metarhizium brunneum), neem, and petroleum spray oils. The control agents were delivered in combination or alone in a single or repeated applications at different times. The plant-derived compound neem (azadirachtin), petroleum spray oil, and fatty acids (M-Pede) only showed moderate effect, although they significantly reduced leaf injuries caused by P. cruciferae and resulted in higher canola yield than the untreated control. Combined use of B. bassiana and M. brunneum in two repeated applications and bifenthrin in five applications were most effective in reducing feeding injuries and improving yield levels at both trial locations. This indicates that entomopathogenic fungi are effective against P. cruciferae, and may serve as alternatives to conventional insecticides or seed treatments in managing this pest.

  2. Development of 6-DOF painting robot control system

    NASA Astrophysics Data System (ADS)

    Huang, Junbiao; Liu, Jianqun; Gao, Weiqiang

    2017-01-01

    With the development of society, the spraying technology of manufacturing industry in China has changed from the manual operation to the 6-DOF (Degree Of Freedom)robot automatic spraying. Spraying painting robot can not only complete the work which does harm to human being, but also improve the production efficiency and save labor costs. Control system is the most critical part of the 6-DOF robots, however, there is still a lack of relevant technology research in China. It is very necessary to study a kind of control system of 6-DOF spraying painting robots which is easy to operation, and has high efficiency and stable performance. With Googol controller platform, this paper develops programs based on Windows CE embedded systems to control the robot to finish the painting work. Software development is the core of the robot control system, including the direct teaching module, playback module, motion control module, setting module, man-machine interface, alarm module, log module, etc. All the development work of the entire software system has been completed, and it has been verified that the entire software works steady and efficient.

  3. Olopatadine Nasal Spray

    MedlinePlus

    ... medications called antihistamines. It works by blocking the effects of histamine, a substance in the body that ... to your pharmacist or contact your local garbage/recycling department to learn about take-back programs in ...

  4. Verification of the hygienic adequacy of beef carcass cooling processes by microbiological culture and the temperature-function integration technique.

    PubMed

    Jericho, K W; O'Laney, G; Kozub, G C

    1998-10-01

    To enhance food safety and keeping quality, beef carcasses are cooled immediately after leaving the slaughter floor. Within hazard analysis and critical control point (HACCP) systems, this cooling process needs to be monitored by the industry and verified by regulatory agencies. This study assessed the usefulness of the temperature-function integration technique (TFIT) for the verification of the hygienic adequacy of two cooling processes for beef carcasses at one abattoir. The cooling process passes carcasses through a spray cooler for at least 17 h and a holding cooler for at least 7 h. The TFIT is faster and cheaper than culture methods. For spray cooler 1, the Escherichia coli generations predicted by TFIT for carcass surfaces (pelvic and shank sites) were compared to estimated E. coli counts from 120 surface excision samples (rump, brisket, and sacrum; 5 by 5 by 0.2 cm) before and after cooling. Counts of aerobic bacteria, coliforms, and E. coli were decreased after spray cooler 1 (P < or = 0.001). The number of E. coli generations (with lag) at the pelvic site calculated by TFIT averaged 0.85 +/- 0.19 and 0.15 +/- 0.04 after emerging from spray coolers 1 and 2, respectively. The TFIT (with lag) was considered convenient and appropriate for the inspection service to verify HACCP systems for carcass cooling processes.

  5. 78 FR 69135 - Petitions for Modification of Application of Existing Mandatory Safety Standards

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-18

    ..., because there is a chance that the water can become polluted from some external event such as a fire or...) The nature of any emergency itself could cause an external water supply to be polluted, choked, or... Affected: 30 CFR 75.1101-1(b) (Deluge-type water spray systems). Modification Request: The petitioner...

  6. Efficacy of three insecticides applied to bark to control Agrilus planipennis (Coleoptera: Buprestidae)

    Treesearch

    Toby R. Petrice; Robert A. Haack

    2006-01-01

    Emerald ash borer (EAB), Agrilus planipennis Fairmaire (Coleoptera: Buprestidae), is a serious exotic pest of ash (Fraxinus) trees in North America. In 2003 and 2004, we tested the efficacy of different insecticides sprayed on the bark of cut ash logs for killing emerging EAB adults. Logs (means: length = 30 cm; diam. = 16 cm) were...

  7. Comparisons of topical and spray applications of two pesticides, triazophos and jinggangmycin, on the protein content in the ovaries and fat bodies of the brown planthopper Nilaparvata lugens Stål (Hemiptera:Delphacidae).

    PubMed

    Zhu, Zhan-Fei; Cheng, Jia; Lu, Xiu-Li; Li, Xin; Ge, Lin-Quan; Fang, Ji-Chao; Wu, Jin-Cai

    2014-09-01

    The pesticide-induced stimulation of reproduction in pests is one of the most important mechanisms of pest resurgence. There have been numerous reports on the insecticide-induced stimulation of reproduction. However, the relationship between pesticide application method and pest resurgence (stimulation of reproduction) has received little attention. Here, we studied the effect of two treatment methods, triazophos (TZP) and jinggangmycin (JGM), on the protein content in the ovaries and fat bodies of the brown planthopper (BPH) Nilaparvata lugens Stål. The results showed that pesticide treatment methods significantly affected the protein content in the ovaries and fat bodies of BPH. In addition, grand means (means of main effect) of the protein content at 2 and 3 days after emergence (2 and 3 DAE) for foliar sprays was significantly higher than that observed after topical treatments, which increased by 23.9% (from 1.42 to 1.76) and 8.82% (from 4.42 to 4.81), respectively. No significant differences on the protein content in the ovaries and fat bodies for the JGM topical treatment were observed compared with controls. However, the protein content for JGM foliar sprays was significantly higher than that for the controls. The protein contents in both topical and spray treatments of TZP were significantly higher than those of the controls. Ovarian protein is mainly yolk protein. There is a positive correlation between ovarian protein content and the number of eggs laid. These findings show that foliar spray of the pesticides promotes the resurgence of BPH. Therefore, the foliar spray of some pesticides, such as JGM, should be avoided for the control of pests, which is the sideeffects of the fungicide on non-target insect pests' occurrence. Copyright © 2014 Elsevier Inc. All rights reserved.

  8. Design Seminar for Land Treatment of Municipal Wastewater Effluents.

    ERIC Educational Resources Information Center

    Demirjian, Y. A.

    This document reports the development and operation of a country-wide wastewater treatment program. The program was designed to treat liquid wastewater by biological treatment in aerated lagoons, store it, and then spray irrigate on crop farmland during the growing season. The text discusses the physical design of the system, agricultural aspects,…

  9. Indoor Residual Spraying Delivery Models to Prevent Malaria: Comparison of Community- and District-Based Approaches in Ethiopia

    PubMed Central

    Johns, Benjamin; Yihdego, Yemane Yeebiyo; Kolyada, Lena; Dengela, Dereje; Chibsa, Sheleme; Dissanayake, Gunawardena; George, Kristen; Taffese, Hiwot Solomon; Lucas, Bradford

    2016-01-01

    ABSTRACT Background: Indoor residual spraying (IRS) for malaria prevention has traditionally been implemented in Ethiopia by the district health office with technical and operational inputs from regional, zonal, and central health offices. The United States President's Malaria Initiative (PMI) in collaboration with the Government of Ethiopia tested the effectiveness and efficiency of integrating IRS into the government-funded community-based rural health services program. Methods: Between 2012 and 2014, PMI conducted a mixed-methods study in 11 districts of Oromia region to compare district-based IRS (DB IRS) and community-based IRS (CB IRS) models. In the DB IRS model, each district included 2 centrally located operational sites where spray teams camped during the IRS campaign and from which they traveled to the villages to conduct spraying. In the CB IRS model, spray team members were hired from the communities in which they operated, thus eliminating the need for transport and camping facilities. The study team evaluated spray coverage, the quality of spraying, compliance with environmental and safety standards, and cost and performance efficiency. Results: The average number of eligible structures found and sprayed in the CB IRS districts increased by 19.6% and 20.3%, respectively, between 2012 (before CB IRS) and 2013 (during CB IRS). Between 2013 and 2014, the numbers increased by about 14%. In contrast, in the DB IRS districts the number of eligible structures found increased by only 8.1% between 2012 and 2013 and by 0.4% between 2013 and 2014. The quality of CB IRS operations was good and comparable to that in the DB IRS model, according to wall bioassay tests. Some compliance issues in the first year of CB IRS implementation were corrected in the second year, bringing compliance up to the level of the DB IRS model. The CB IRS model had, on average, higher amortized costs per district than the DB IRS model but lower unit costs per structure sprayed and per person protected because the community-based model found and sprayed more structures. Conclusion: Established community-based service delivery systems can be adapted to include a seasonal IRS campaign alongside the community-based health workers' routine activities to improve performance efficiency. Further modifications of the community-based IRS model may reduce the total cost of the intervention and increase its financial sustainability. PMID:27965266

  10. THE BUREAU OF AERONAUTICS RESEARCH AND DEVELOPMENT PROGRAM FOR WATER-BASED AIRCRAFT,

    DTIC Science & Technology

    WATER BASED AIRCRAFT, BUDGETS), RESEARCH MANAGEMENT, FLIGHT TESTING, WIND TUNNEL MODELS, TABLES(DATA), AIRCRAFT, TEST VEHICLES, HYDRODYNAMICS, PIERS, FLOATING DOCKS, LOADS(FORCES), WATER , STABILITY, SPRAYS, NAVAL AIRCRAFT.

  11. Experience with mass drug administration as a supplementary attack measure in areas of vivax malaria

    PubMed Central

    Onori, E.

    1972-01-01

    Mass drug administration was introduced in Syria to supplement DDT spraying after the main malaria vector Anopheles sacharovi had developed considerable resistance to the insecticide. Mass administration of weekly doses of chloroquine and pyrimethamine was carried out in the Ghab area from August to October, the coverage obtained being over 80% for most of the time. The number of cases with positive blood films declined rapidly from August onwards. Entomological observations showed that the house-resting density decreased shortly after the second round of DDT spraying but soon regained its previous level. Some relapsing cases were detected in 1969 but none were found in 1970, and it is considered that the possibility of relapses should not deter authorities from using mass drug administration in emergency situations. PMID:4573215

  12. Induction of virus resistance by exogenous application of double-stranded RNA.

    PubMed

    Mitter, Neena; Worrall, Elizabeth A; Robinson, Karl E; Xu, Zhi Ping; Carroll, Bernard J

    2017-10-01

    Exogenous application of double-stranded RNA (dsRNA) for virus resistance in plants represents a very attractive alternative to virus resistant transgenic crops or pesticides targeting virus vectors. However, the instability of dsRNA sprayed onto plants is a major challenge as spraying naked dsRNA onto plants provides protection against homologous viruses for only 5 days. Innovative approaches, such as the use of nanoparticles as carriers of dsRNA for improved stability and sustained release, are emerging as key disruptive technologies. Knowledge is still limited about the mechanism of entry, transport and processing of exogenously applied dsRNA in plants. Cost of dsRNA and regulatory framework will be key influencers towards practical adoption of this technology. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Toxic alveolitis after inhalation of a water repellent.

    PubMed

    Epping, Guido; Van Baarlen, Joop; Van Der Valk, Paul D L P M

    2011-12-01

    Inhalation of fluorocarbon polymers can cause pulmonary toxicity. Although multiple cases of lung injury have been reported, cellular characterization of the associated alveolitis occurring acutely after inhalation is limited. We report the case of a previously healthy woman who presented at our Emergency Department with an acute pneumonitis following inhalation of a fluorocarbon polymer-based rain-proofing spray. Bronchoalveolar lavage (BAL) performed shortly after the presentation showed an elevated total cell count, with a high proportion of neutrophils (58%) and eosinophils (9%). In addition, a lipid stain (Oil-Red-O-stain) showed a high level of lipid laden macrophages, a marker that could reflect a direct toxic effect of the spray on alveolar cells. The patient made a full recovery after four days of in-hospital observation with supportive care.

  14. Effects of spray-dried whole egg and biotin in calf milk replacer.

    PubMed

    Quigley, J D

    2002-01-01

    Holstein bull calves (n = 120) were fed milk replacers containing 0, 10, or 20% of the formulation (0, 22, or 44% of crude protein) as spray-dried whole egg powder in a 56-d feeding trial. Milk replacer was medicated with oxytetracycline and neomycin and was fed from d 1 to 42 of the study in a phase-fed program. All experimental milk replacers were supplemented with B vitamins, except biotin. One half of all calves were supplemented with 1 mg/kg of supplemental biotin to determine whether avidin in the egg protein product inhibited growth. Increasing spray-dried whole egg caused a linear reduction in body weight, body weight gain at 28 and 56 d of the study, calf starter intake, and feed efficiency. Calves fed milk replacers containing 0, 10, and 20% spray-dried whole egg gained an average of 486, 369, and 302 g/d, respectively, during the 56-d trial. Efficiency of feed utilization was 446, 318, and 231 g of body weight gain per kilogram of dry matter intake. Improvement in body weight and feed efficiency occurred when calves began consuming calf starter on d 29. Digestibility of protein or fat from egg may have been reduced during the trial; however, the addition of biotin to the milk replacer did not influence animal performance, suggesting that avidin in spray-dried whole egg was not responsible for impaired performance. The spray-dried whole egg product used in this study did not provide nutrients to support adequate growth of milk-fed calves.

  15. 10 CFR 431.263 - Materials incorporated by reference.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... Society for Testing and Materials (ASTM) Standard F2324-03, “Standard Test Method for Prerinse Spray..., Forrestal Building, Room 1J-018 (Resource Room of the Building Technologies Program), 1000 Independence...

  16. 10 CFR 431.263 - Materials incorporated by reference.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Society for Testing and Materials (ASTM) Standard F2324-03, “Standard Test Method for Prerinse Spray..., Forrestal Building, Room 1J-018 (Resource Room of the Building Technologies Program), 1000 Independence...

  17. Metallized coatings for corrosion control of Naval ship structures and components

    NASA Technical Reports Server (NTRS)

    1983-01-01

    In attempting to improve corrosion control, the U.S. Navy has undertaken a program of coating corrosion-susceptible shipboard components with thermally sprayed aluminum. In this report the program is reviewed in depth, including examination of processes, process controls, the nature and properties of the coatings, nondestructive examination, and possible hazards to personnel. The performance of alternative metallic coating materials is also discussed. It is concluded that thermally sprayed aluminum can provide effective long-term protection against corrosion, thereby obviating the need for chipping of rust and repainting by ship personnel. Such coatings are providing excellent protection to below-deck components such as steam valves, but improvements are needed to realize the full potential of coatings for above-deck service. Several recommendations are made regarding processes, materials, and research and development aimed at upgrading further the performance of these coatings.

  18. Fuel-injector/air-swirl characterization

    NASA Technical Reports Server (NTRS)

    Mcvey, J. B.; Kennedy, J. B.; Bennett, J. C.

    1985-01-01

    The objectives of this program are to establish an experimental data base documenting the behavior of gas turbine engine fuel injector sprays as the spray interacts with the swirling gas flow existing in the combustor dome, and to conduct an assessment of the validity of current analytical techniques for predicting fuel spray behavior. Emphasis is placed on the acquisition of data using injector/swirler components which closely resemble components currently in use in advanced aircraft gas turbine engines, conducting tests under conditions that closely simulate or closely approximate those developed in actual combustors, and conducting a well-controlled experimental effort which will comprise using a combination of low-risk experiments and experiments requiring the use of state-of-the-art diagnostic instrumentation. Analysis of the data is to be conducted using an existing, TEACH-type code which employs a stochastic analysis of the motion of the dispersed phase in the turbulent continuum flow field.

  19. Terascale High-Fidelity Simulations of Turbulent Combustion with Detailed Chemistry: Spray Simulations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rutland, Christopher J.

    2009-04-26

    The Terascale High-Fidelity Simulations of Turbulent Combustion (TSTC) project is a multi-university collaborative effort to develop a high-fidelity turbulent reacting flow simulation capability utilizing terascale, massively parallel computer technology. The main paradigm of the approach is direct numerical simulation (DNS) featuring the highest temporal and spatial accuracy, allowing quantitative observations of the fine-scale physics found in turbulent reacting flows as well as providing a useful tool for development of sub-models needed in device-level simulations. Under this component of the TSTC program the simulation code named S3D, developed and shared with coworkers at Sandia National Laboratories, has been enhanced with newmore » numerical algorithms and physical models to provide predictive capabilities for turbulent liquid fuel spray dynamics. Major accomplishments include improved fundamental understanding of mixing and auto-ignition in multi-phase turbulent reactant mixtures and turbulent fuel injection spray jets.« less

  20. Caracterisation of Titanium Nitride Layers Deposited by Reactive Plasma Spraying

    NASA Astrophysics Data System (ADS)

    Roşu, Radu Alexandru; Şerban, Viorel-Aurel; Bucur, Alexandra Ioana; Popescu, Mihaela; Uţu, Dragoş

    2011-01-01

    Forming and cutting tools are subjected to the intense wear solicitations. Usually, they are either subject to superficial heat treatments or are covered with various materials with high mechanical properties. In recent years, thermal spraying is used increasingly in engineering area because of the large range of materials that can be used for the coatings. Titanium nitride is a ceramic material with high hardness which is used to cover the cutting tools increasing their lifetime. The paper presents the results obtained after deposition of titanium nitride layers by reactive plasma spraying (RPS). As deposition material was used titanium powder and as substratum was used titanium alloy (Ti6Al4V). Macroscopic and microscopic (scanning electron microscopy) images of the deposited layers and the X ray diffraction of the coatings are presented. Demonstration program with layers deposited with thickness between 68,5 and 81,4 μm has been achieved and presented.

  1. Lessons Learned from School Crises and Emergencies. Volume 1, Issue 1, Fall 2006

    ERIC Educational Resources Information Center

    US Department of Education, 2006

    2006-01-01

    This issue of "Lessons Learned" addresses "Dealing with Weapons on Campus." Each year, school administrators, faculty and staff must deal with the possibility of students planning and carrying out pranks such as toilet-papering trees, egging automobiles or spray painting school property. These high jinks often occur at the end of the school year,…

  2. Sea Spray and Icing in the Emerging Open Water of the Arctic Ocean

    DTIC Science & Technology

    2014-09-30

    CRREL personnel for this project are Kathy Jones, Chris Williams, and Kerry Claffey. Ed Andreas of NWRA is the co-PI with Jones. We borrowed Chris ...Mitchell K, Shafran P, Ebisuzaki W, Jovic D, Woollen J, Rogers E, Berbery EH, Ek MB, Fan Y, Grumbine R, Higgins W, Li H, Lin Y, Manikin G, Parrish D

  3. 76 FR 49381 - Oranges and Grapefruit Grown in Lower Rio Grande Valley in Texas; Increased Assessment Rate

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-10

    ... promotion law should fund an independent evaluation of the effectiveness of their generic promotion program..., trapping, and bait spray programs; $425,000 for promotion; and $250,737 for management, administration, and... production area, few have sufficient acreage to generate sales in excess of $750,000. Thus, half of the...

  4. 76 FR 61249 - Oranges and Grapefruit Grown in Lower Rio Grande Valley in Texas; Increased Assessment Rate

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-04

    ... under the oversight of the Secretary of Agriculture pursuant to a commodity promotion law should fund an independent evaluation of the effectiveness of their generic promotion program, which is now commonly known as..., trapping, and bait spray programs; $425,000 for promotion; and $250,737 for management, administration, and...

  5. An Apollo compatible cloud physics experiment.

    NASA Technical Reports Server (NTRS)

    Eaton, L. R.; Hollinden, A. B.; Satterblom, P. R.

    1973-01-01

    Consideration of the utilization of a low-gravity environment to obtain experimental information, in the area of cloud microphysics, which cannot be obtained in ground laboratories. The experiment discussed is designed to obtain quantitative answers about evaporation and breakup of salt particles from ocean spray and other sources. In addition to salt nuclei distribution mechanisms, this breakup has ecological importance in relation to the spreading of salt mists from salted highways and spreading of brine cooling tower spray from electrical power generation plants. This experiment is being submitted for consideration on the Apollo-Soyuz Test Program in 1975.

  6. A numerical calculation of outward propagation of solar disturbances. [solar atmospheric model with shock wave propagation

    NASA Technical Reports Server (NTRS)

    Wu, S. T.

    1974-01-01

    The responses of the solar atmosphere due to an outward propagation shock are examined by employing the Lax-Wendroff method to solve the set of nonlinear partial differential equations in the model of the solar atmosphere. It is found that this theoretical model can be used to explain the solar phenomena of surge and spray. A criterion to discriminate the surge and spray is established and detailed information concerning the density, velocity, and temperature distribution with respect to the height and time is presented. The complete computer program is also included.

  7. 40 CFR 721.555 - Alkyl amino nitriles (generic).

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... (c). A full face shield is required if splashing or spraying occurs. (ii) Hazard communication program. Requirements as specified in § 721.72 (c)(1) and (c)(2)(iv). The MSDS required by this paragraph...

  8. 40 CFR 721.555 - Alkyl amino nitriles (generic).

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... (c). A full face shield is required if splashing or spraying occurs. (ii) Hazard communication program. Requirements as specified in § 721.72 (c)(1) and (c)(2)(iv). The MSDS required by this paragraph...

  9. 40 CFR 721.555 - Alkyl amino nitriles (generic).

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... (c). A full face shield is required if splashing or spraying occurs. (ii) Hazard communication program. Requirements as specified in § 721.72 (c)(1) and (c)(2)(iv). The MSDS required by this paragraph...

  10. 40 CFR 721.555 - Alkyl amino nitriles (generic).

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... (c). A full face shield is required if splashing or spraying occurs. (ii) Hazard communication program. Requirements as specified in § 721.72 (c)(1) and (c)(2)(iv). The MSDS required by this paragraph...

  11. Environmental Technology Verification: Pesticide Spray Drift Reduction Technologies for Row and Field Crops

    EPA Pesticide Factsheets

    The Environmental Technology Verification Program, established by the EPA, is designed to accelerate the development and commercialization of new or improved technologies through third-party verification and reporting of performance.

  12. Verification on spray simulation of a pintle injector for liquid rocket engine

    NASA Astrophysics Data System (ADS)

    Son, Min; Yu, Kijeong; Radhakrishnan, Kanmaniraja; Shin, Bongchul; Koo, Jaye

    2016-02-01

    The pintle injector used for a liquid rocket engine is a newly re-attracted injection system famous for its wide throttle ability with high efficiency. The pintle injector has many variations with complex inner structures due to its moving parts. In order to study the rotating flow near the injector tip, which was observed from the cold flow experiment using water and air, a numerical simulation was adopted and a verification of the numerical model was later conducted. For the verification process, three types of experimental data including velocity distributions of gas flows, spray angles and liquid distribution were all compared using simulated results. The numerical simulation was performed using a commercial simulation program with the Eulerian multiphase model and axisymmetric two dimensional grids. The maximum and minimum velocities of gas were within the acceptable range of agreement, however, the spray angles experienced up to 25% error when the momentum ratios were increased. The spray density distributions were quantitatively measured and had good agreement. As a result of this study, it was concluded that the simulation method was properly constructed to study specific flow characteristics of the pintle injector despite having the limitations of two dimensional and coarse grids.

  13. Detection and Characterization of Flaws in Sprayed on Foam Insulation with Pulsed Terahertz Frequency Electromagnetic Waves

    NASA Technical Reports Server (NTRS)

    Winfree, William P.; Madaras, Eric I.

    2005-01-01

    The detection and repair of flaws such as voids and delaminations in the sprayed on foam insulation of the external tank reduces the probability of foam debris during shuttle ascent. The low density of sprayed on foam insulation along with it other physical properties makes detection of flaws difficult with conventional techniques. An emerging technology that has application for quantitative evaluation of flaws in the foam is pulsed electromagnetic waves at terahertz frequencies. The short wavelengths of these terahertz pulses make them ideal for imaging flaws in the foam. This paper examines the application of terahertz pulses for flaw detection in foam characteristic of the foam insulation of the external tank. Of particular interest is the detection of voids and delaminations, encapsulated in the foam or at the interface between the foam and a metal backing. The technique is shown to be capable of imaging small voids and delaminations through as much as 20 cm of foam. Methods for reducing the temporal responses of the terahertz pulses to improve flaw detection and yield quantitative characterizations of the size and location of the flaws are discussed.

  14. AmeriFlux US-AR2 ARM USDA UNL OSU Woodward Switchgrass 2

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Billesbach, Dave; Bradford, James

    This is the AmeriFlux version of the carbon flux data for the site US-AR2 ARM USDA UNL OSU Woodward Switchgrass 2. Site Description - The ARM USDA UNL OSU Woodward Switchgrass 2 tower is located on public land owned by the USDA-ARS Southern Plains Range Research Station in Woodward, Oklahoma. The site is on a former wheat field that is in the process of changing to switchgrass. A companion site (ARM USDA UNL OSU Woodward Switchgrass 1) is on a former native prairie. Previous wheat was planted in Fall 2008. In Spring 2009, herbicide was applied to kill the wheatmore » prior to switchgrass planting. Later in the year, the site was sprayed with post-emergence herbicide. In 2010, fertilization occurred before herbicide was sprayed for broadleaf control.« less

  15. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT: EXEL INDUSTRIAL AIRMIX SPRAY GUN

    EPA Science Inventory

    The Environmental Technology Verification Program has partnered with Concurrent Technologies Corp. to verify innovative coatings and coating equipment technologies for reducing air emissions. This report describes the performance of EXEL Industrial's Kremlin Airmix high transfer ...

  16. Regional differences in time to pregnancy among fertile women from five Colombian regions with different use of glyphosate.

    PubMed

    Sanin, Luz-Helena; Carrasquilla, Gabriel; Solomon, Keith R; Cole, Donald C; Marshall, E J P

    2009-01-01

    The objective of this study was to test whether there was an association between the use of glyphosate when applied by aerial spray for the eradication of illicit crops (cocaine and poppy) and time to pregnancy (TTP) among fertile women. A retrospective cohort study (with an ecological exposure index) of first pregnancies was undertaken in 2592 fertile Colombian women from 5 regions with different uses of glyphosate. Women were interviewed regarding potential reproductive, lifestyle, and work history predictors of TTP, which was measured in months. Fecundability odds ratios (fOR) were estimated using a discrete time analogue of Cox's proportional hazard model. There were differences in TTP between regions. In the final multivariate model, the main predictor was the region adjusted by irregular relationship with partner, maternal age at first pregnancy, and, marginally, coffee consumption and self-perception of water pollution. Boyaca, a region with traditional crops and. recently, illicit crops without glyphosate eradication spraying (manual eradication), displayed minimal risk and was the reference region. Other regions, including Sierra Nevada (control area, organic agriculture), Putumayo and Narino (illicit crops and intensive eradication spray program), and Valle del Cauca, demonstrated greater risk of longer TTP, with the highest risk for Valle del Cauca (fOR 0.15, 95% CI 0.12, 0.18), a sugar-cane region with a history of use of glyphosate and others chemicals for more than 30 yr. The reduced fecundability in some regions was not associated with the use of glyphosate for eradication spraying. The observed ecological differences remain unexplained and may be produced by varying exposures to environmental factors, history of contraceptive programs in the region, or psychological distress. Future studies examining these or other possible causes are needed.

  17. Household cleaning product-related injuries treated in US emergency departments in 1990-2006.

    PubMed

    McKenzie, Lara B; Ahir, Nisha; Stolz, Uwe; Nelson, Nicolas G

    2010-09-01

    The goal was to examine comprehensively the patterns and trends of household cleaning product-related injuries among children treated in US emergency departments. Through use of the National Electronic Injury Surveillance System database, cases of unintentional, nonfatal, household cleaning product-related injuries were selected by using product codes for drain cleaners, ammonia, metal polishes/tarnish removers, turpentine, dishwasher detergents, acids, swimming pool chemicals, oven cleaners, pine oil cleaners/disinfectants, laundry soaps/detergents, toilet bowl products, abrasive cleaners, general-purpose household cleaners, noncosmetic bleaches, windshield wiper fluids, caustic agents, lye, wallpaper cleaners, room deodorizers/fresheners, spot removers, and dishwashing liquids. Products were categorized according to major toxic ingredients, mode of action, and exposure. An estimated 267 269 children

  18. Superoleophobic Surfaces through Control of Sprayed-on Stochastic Topography (Pre-Print)

    DTIC Science & Technology

    2012-05-01

    Tuteja, A.; Choi, W.; McKinley, G. H.; Cohen, R. E.; Rubner, M. F., Design Parameters for Superhydrophobicity and Superoleophobicity. MRS Bull. 2008...Surfaces. Langmuir 2010, 26, 4027-4035. 5. Bhushan, B.; Jung, Y. C., Natural and biomimetic artificial surfaces for superhydrophobicity , self-cleaning...Mater. 2009, 21, 2190-2195. 9. Nosonovsky, M.; Bhushan, B., Superhydrophobic surfaces and emerging applications: Non- adhesion, energy, green

  19. Emergency treatment of exertional heatstroke and comparison of whole body cooling techniques.

    PubMed

    Costrini, A

    1990-02-01

    This manuscript compares the whole body cooling techniques in the emergency treatment of heatstroke. Historically, the use of cold water immersion with skin massage has been quite successful in rapidly lowering body temperature and in avoiding severe complications or death. Recent studies have suggested alternative therapies, including the use of a warm air spray, the use of helicopter downdraft, and pharmacological agents. While evidence exists to support these methods, they have not been shown to reduce fatalities as effectively as ice water immersion. Although several cooling methods may have clinical use, all techniques rely on the prompt recognition of symptoms and immediate action in the field.

  20. Chagas Disease Vector Control in a Hyperendemic Setting: The First 11 Years of Intervention in Cochabamba, Bolivia

    PubMed Central

    Espinoza, Natalisisy; Borrás, Rafael; Abad-Franch, Fernando

    2014-01-01

    Background Chagas disease has historically been hyperendemic in the Bolivian Department of Cochabamba. In the early 2000s, an extensive vector control program was implemented; 1.34 million dwelling inspections were conducted to ascertain infestation (2000–2001/2003–2011), with blanket insecticide spraying in 2003–2005 and subsequent survey-spraying cycles targeting residual infestation foci. Here, we assess the effects of this program on dwelling infestation rates (DIRs). Methodology/Principal Findings Program records were used to calculate annual, municipality-level aggregate DIRs (39 municipalities); very high values in 2000–2001 (median: 0.77–0.69) dropped to ∼0.03 from 2004 on. A linear mixed model (with municipality as a random factor) suggested that infestation odds decreased, on average, by ∼28% (95% confidence interval [CI95] 6–44%) with each 10-fold increase in control effort. A second, better-fitting mixed model including year as an ordinal predictor disclosed large DIR reductions in 2001–2003 (odds ratio [OR] 0.11, CI95 0.06–0.19) and 2003–2004 (OR 0.22, CI95 0.14–0.34). Except for a moderate decrease in 2005–2006, no significant changes were detected afterwards. In both models, municipality-level DIRs correlated positively with previous-year DIRs and with the extent of municipal territory originally covered by montane dry forests. Conclusions/Significance Insecticide-spraying campaigns had very strong, long-lasting effects on DIRs in Cochabamba. However, post-intervention surveys consistently detected infestation in ∼3% of dwellings, underscoring the need for continuous surveillance; higher DIRs were recorded in the capital city and, more generally, in municipalities dominated by montane dry forest – an eco-region where wild Triatoma infestans are widespread. Traditional strategies combining insecticide spraying and longitudinal surveillance are thus confirmed as very effective means for area-wide Chagas disease vector control; they will be particularly beneficial in highly-endemic settings, but should also be implemented or maintained in other parts of Latin America where domestic infestation by triatomines is still commonplace. PMID:24699407

  1. LOX/Hydrogen Coaxial Injector Atomization Test Program

    NASA Technical Reports Server (NTRS)

    Zaller, M.

    1990-01-01

    Quantitative information about the atomization of injector sprays is needed to improve the accuracy of computational models that predict the performance and stability margin of liquid propellant rocket engines. To obtain this data, a facility for the study of spray atomization is being established at NASA-Lewis to determine the drop size and velocity distributions occurring in vaporizing liquid sprays at supercritical pressures. Hardware configuration and test conditions are selected to make the cold flow simulant testing correspond as closely as possible to conditions in liquid oxygen (LOX)/gaseous H2 rocket engines. Drop size correlations from the literature, developed for liquid/gas coaxial injector geometries, are used to make drop size predictions for LOX/H2 coaxial injectors. The mean drop size predictions for a single element coaxial injector range from 0.1 to 2000 microns, emphasizing the need for additional studies of the atomization process in LOX/H2 engines. Selection of cold flow simulants, measured techniques, and hardware for LOX/H2 atomization simulations are discussed.

  2. Impact Response of Thermally Sprayed Metal Deposits

    NASA Astrophysics Data System (ADS)

    Wise, J. L.; Hall, A. C.; Moore, N. W.; Pautz, S. D.; Franke, B. C.; Scherzinger, W. M.; Brown, D. W.

    2017-06-01

    Gas-gun experiments have probed the impact response of tantalum specimens that were additively manufactured using a controlled thermal spray deposition process. Velocity interferometer (VISAR) diagnostics provided time-resolved measurements of sample response under one-dimensional (i . e . , uniaxial strain) shock compression to peak stresses ranging between 1 and 4 GPa. The acquired wave-profile data have been analyzed to determine the Hugoniot Elastic Limit (HEL), Hugoniot equation of state, and high-pressure yield strength of the thermally deposited samples for comparison to published baseline results for conventionally wrought tantalum. The effects of composition, porosity, and microstructure (e . g . , grain/splat size and morphology) are assessed to explain differences in the dynamic mechanical behavior of spray-deposited versus conventional material. Sandia National Laboratories is a multi-program laboratory managed and operated by Sandia Corporation, a wholly owned subsidiary of Lockheed Martin Corporation, for the U.S. Department of Energy's National Nuclear Security Administration under contract DE-AC04-94AL85000.

  3. Microgravity Spray Cooling Research for High Powered Laser Applications

    NASA Technical Reports Server (NTRS)

    Zivich, Chad P.

    2004-01-01

    An extremely powerful laser is being developed at Goddard Space Flight Center for use on a satellite. This laser has several potential applications. One application is to use it for upper atmosphere weather research. In this case, the laser would reflect off aerosols in the upper atmosphere and bounce back to the satellite, where the aerosol velocities could be calculated and thus the upper atmosphere weather patterns could be monitored. A second application would be for the US. Air Force, which wants to use the laser strategically as a weapon for satellite defense. The Air Force fears that in the coming years as more and more nations gain limited space capabilities that American satellites may become targets, and the laser could protect the satellites. Regardless of the ultimate application, however, a critical step along the way to putting the laser in space is finding a way to efficiently cool it. While operating the laser becomes very hot and must be cooled to prevent overheating. On earth, this is accomplished by simply running cool tap water over the laser to keep it cool. But on a satellite, this is too inefficient. This would require too much water mass to be practical. Instead, we are investigating spray cooling as a means to cool the laser in microgravity. Spray cooling requires much less volume of fluid, and thus could be suitable for use on a satellite. We have inherited a 2.2 second Drop Tower rig to conduct our research with. In our experiments, water is pressurized with a compressed air tank and sprayed through a nozzle onto our test plate. We can vary the pressure applied to the water and the temperature of the plate before an experiment trial. The whole process takes place in simulated microgravity in the 2.2 second Drop Tower, and a high speed video camera records the spray as it hits the plate. We have made much progress in the past few weeks on these experiments. The rig originally did not have the capability to heat the test plate, but I did some heat transfer calculations and picked out a heater to order for the rig. I learned QBasic programming language to change the operating code for our drops, allowing us to rapidly cycle the spray nozzle open and closed to study the effects. We have derived an equation for flow rate vs. pressure for our experiment. We have recorded several videos of drops at different pressures, some with heated test plate and some without, and have noticed substantial differences in the liquid behavior. I have also changed the computer program to write a file with temperature vs. time profiles for the test plate, and once the necessary thermocouple comes in (it was ordered last week), we will have temperature profiles to accompany the videos. Once we have these temperature profiles to go with the videos, we will be able to see how the temperature is affected by the spray at different pressures, and how the spray changes its behavior once as the plate changes from hot to cool. With quantitative temperature data, we can then mathematically model the heat transfer from the plate to the cooling spray. Finally, we can look at the differences between trials in microgravity and those in normal earth gravity.

  4. Effect of Fusarium isolates and their filtrates on respiratory rate and chemical analysis of squash plants.

    PubMed

    El-Shenawy, Z; Mansour, M A; El-Behrawi, S

    1978-01-01

    The highly pathogenic isolate stimulated the emergence of the squash seedlings first, caused, however, the highest death rate of the seedlings finally. Fusarium isolates and their culture filtrates inhibited the respiratory rate of squash plants significantly. However, F. oxysporum isolates inhibited respiration more than F. solani isolates. Seasonal changes of respiration decline show that the respiratory rate decreased with plant growth in the case of infested soil and of plants injected with culture filtrates. However, spraying Fusarium culture filtrates on the foliage gave opposite results when the plants grew older. Fusarium solani isolates decreased nitrogen content of squash stems and leaves, while F. oxysporum isolates gave reverse results. Injecting Fusarium culture filtrate into the plant decreased nitrogen content of both stems and leaves, while spraying the foliage with the filtrates increased nitrogen content more than that of the control. Phosphorus content of the stems of squash plants, sown in infested soil, was less than in the control when the plants were treated with F. solani and higher when they were treated with F. oxysporum isolates. On the other hand, the phosphorus content of squash leaves was higher than in the control. In the case of injected plants, however, the phosphorus content in stems and leaves was equal to that of the control or less, and with sprayed plants it was higher than in the control. Infesting the soil with Fusarium isolates and spraying the foliage with their culture filtrates increased potassium content of squash stems and leaves, while injecting the filtrates into the plants decreased potassium content of both stems and leaves.

  5. Triatomine Infestation in Guatemala: Spatial Assessment after Two Rounds of Vector Control

    PubMed Central

    Manne, Jennifer; Nakagawa, Jun; Yamagata, Yoichi; Goehler, Alexander; Brownstein, John S.; Castro, Marcia C.

    2012-01-01

    In 2000, the Guatemalan Ministry of Health initiated a Chagas disease program to control Rhodnius prolixus and Triatoma dimidiata by periodic house spraying with pyrethroid insecticides to characterize infestation patterns and analyze the contribution of programmatic practices to these patterns. Spatial infestation patterns at three time points were identified using the Getis-Ord Gi*(d) test. Logistic regression was used to assess predictors of reinfestation after pyrethroid insecticide administration. Spatial analysis showed high and low clusters of infestation at three time points. After two rounds of spray, 178 communities persistently fell in high infestation clusters. A time lapse between rounds of vector control greater than 6 months was associated with 1.54 (95% confidence interval = 1.07–2.23) times increased odds of reinfestation after first spray, whereas a time lapse of greater than 1 year was associated with 2.66 (95% confidence interval = 1.85–3.83) times increased odds of reinfestation after first spray compared with localities where the time lapse was less than 180 days. The time lapse between rounds of vector control should remain under 1 year. Spatial analysis can guide targeted vector control efforts by enabling tracking of reinfestation hotspots and improved targeting of resources. PMID:22403315

  6. The Effect of Designated Pollutants on Plant Species

    DTIC Science & Technology

    1981-01-01

    49 33 Dry weight of marigolds exposed to four weekly acid sprays and harvested on fifth week o . . . . . . 0 .. . .. .. 49 34...fertilizer and 12 kg pre-emergence weed killer (Dacthal) per hectare during plowing. Two-week-old zinnia and marigold plants, started in peat pots in the...study described below. Effect on Yield Zinnia and marigold plants transplanted to a Riverside field were exposed weekly for 6 successive weeks to one

  7. NEUTRONIC REACTOR WITH ACCESSIBLE THIMBLE AND EMERGENCY COOLING FEATURES

    DOEpatents

    McCorkle, W.H.

    1960-02-23

    BS>A safety system for a water-moderated reactor is described. The invention comprises a reservoir system for spraying the fuel elements within a fuel assembly with coolant and keeping them in a continuous bath even if the coolant moderator is lost from the reactor vessel. A reservoir gravity feeds one or more nozzels positioned within each fuel assembly which continually forces water past the fuel elements.

  8. Liquid rocket combustion computer model with distributed energy release. DER computer program documentation and user's guide, volume 1

    NASA Technical Reports Server (NTRS)

    Combs, L. P.

    1974-01-01

    A computer program for analyzing rocket engine performance was developed. The program is concerned with the formation, distribution, flow, and combustion of liquid sprays and combustion product gases in conventional rocket combustion chambers. The capabilities of the program to determine the combustion characteristics of the rocket engine are described. Sample data code sheets show the correct sequence and formats for variable values and include notes concerning options to bypass the input of certain data. A seperate list defines the variables and indicates their required dimensions.

  9. Recommendations for the Investigation of Vapor Intrusion

    DTIC Science & Technology

    2007-12-01

    1,1-dfa 1,1- difluoroethane EPA U.S. Environmental Protection Agency ESTCP Environmental Security Technology Certification Program NHDES...the leak tracer itself caused significant problems. During this sample event, 1,1- difluoroethane (1,1-dfa, the propellant in duster spray) was used

  10. WaterSense Specification for Commercial Pre-Rinse Spray Valves Supporting Statement

    EPA Pesticide Factsheets

    The U.S. Environmental Protection Agency’s (EPA’s) WaterSense program released a specification for PRSVs to earn the WaterSense label on September 19, 2013, in order to further improve the nation’s water and energy efficiency.

  11. 40 CFR 180.108 - Acephate; tolerances for residues.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... establishments, including food service, manufacturing and processing establishments, such as restaurants... avoid atomization or splashing of the spray. Contamination of food or food-contact surfaces shall be... PROGRAMS TOLERANCES AND EXEMPTIONS FOR PESTICIDE CHEMICAL RESIDUES IN FOOD Specific Tolerances § 180.108...

  12. EXPERIMENTAL INVESTIGATION OF CRITICAL FUNDAMENTAL ISSUES IN HAZARDOUS WASTE INCINERATION

    EPA Science Inventory

    The report gives results of a laboratory-scale program investigating several fundamental issues involved in hazardous waste incineration. The key experiment for each study was the measurement of waste destruction behavior in a sub-scale turbulent spray flame. (1) Atomization Qual...

  13. Cannabinoids therapeutic use: what is our current understanding following the introduction of THC, THC:CBD oromucosal spray and others?

    PubMed

    Maccarrone, Mauro; Maldonado, Rafael; Casas, Miguel; Henze, Thomas; Centonze, Diego

    2017-04-01

    The complexity of the endocannabinoid (eCB) system is becoming better understood and new drivers of eCB signaling are emerging. Modulation of the activities of the eCB system can be therapeutic in a number of diseases. Research into the eCB system has been paralleled by the development of agents that interact with cannabinoid receptors. In this regard it should be remembered that herbal cannabis contains a myriad of active ingredients, and the individual cannabinoids have quite distinct biological activities requiring independent studies. Areas covered: This article reviews the most important current data involving the eCB system in relation to human diseases, to reflect the present (based mainly on the most used prescription cannabinoid medicine, THC/CBD oromucosal spray) and potential future uses of cannabinoid-based therapy. Expert commentary: From the different therapeutic possibilities, THC/CBD oromucosal spray has been in clinical use for approximately five years in numerous countries world-wide for the management of multiple sclerosis (MS)-related moderate to severe resistant spasticity. Clinical trials have confirmed its efficacy and tolerability. Other diseases in which different cannabinoids are currently being investigated include various pain states, Alzheimer's disease, Parkinson's disease, Huntington's disease and epilepsy. The continued characterization of individual cannabinoids in different diseases remains important.

  14. Use of shaking treatments and preharvest sprays of pyrethroid insecticides to reduce risk of yellowjackets and other insects on Christmas trees imported into Hawaii.

    PubMed

    Hollingsworth, Robert G; Chastagner, Gary A; Reimer, Neil J; Oishi, Darcy E; Landolt, Peter J; Paull, Robert E

    2009-02-01

    Insects are commonly found by Hawaii's quarantine inspectors on Christmas trees imported from the Pacific Northwest. To reduce the risk of importing yellowjacket (Vespula spp.) queens and other insects, an inspection and tree shaking certification program was begun in 1990. From 1993 to 2006, the annual percentage of shipped containers rated by Hawaii quarantine inspectors as moderately or highly infested with insects was significantly higher for manually shaken trees than for mechanically shaken trees. Between 1993 and 2001, 343 insect species in total were recovered from Christmas trees. Live western yellowjacket [Vespula pensylvanica (Saussure)] queens were intercepted both from containers certified as manually shaken and from containers certified as mechanically shaken. The standard manual shaking protocol removed about one-half of the queens from Douglas fir [Pseudotsuga menziesii (Mirb.) Franco] trees that were naturally infested with western yellowjacket queens. We investigated the use of preharvest sprays of permethrin as a complement to shaking procedures used to control yellowjackets and other insects. Western yellowjacket queens and honey bees (surrogates for wasp pests) were exposed to Noble fir foliage that had been sprayed in the field with permethrin > 6 wk before harvest. Pesticide residues provided complete control (moribundity or mortality) in both species. The sprays did not affect needle retention or quality of Noble fir foliage. We conclude that preharvest sprays of pyrethroid insecticides could be used in combination with mechanical shaking to greatly reduce the quarantine risk of yellowjacket queens and other insects in exported Christmas trees.

  15. Comparison of the hazards posed to amphibians by the glyphosate spray control program versus the chemical and physical activities of coca production in Colombia.

    PubMed

    Brain, Richard A; Solomon, Keith R

    2009-01-01

    This study evaluates the cumulative multifactorial physical and chemical impacts resulting from coca production on amphibian populations in comparison with the potential impacts produced by the herbicide glyphosate (Glyphos), which, mixed with the surfactant Cosmo-Flux, is used in the spray control program for illicit crops in Colombia. Using similar worst-case assumptions for exposure, several other pesticides used for coca production, including mancozeb, lambda cyhalothrin, endosulfan, diazinon, malathion, and chlorpyrifos, were up to 10- to 100-fold more toxic to frogs than the Glyphos-Cosmo-Flux mixture. Comparing hazard quotients based on application rates, several of these compounds demonstrated hazards 3-383 times that of formulated glyphosate. Secondary effects, particularly of insecticides, are also a concern, as these agents selectively target the primary food source of amphibians, which may indirectly impact growth and development. Although the potential chemical impacts by other pesticides are considerable, physical activities associated with coca production, particularly deforestation of primary forests for new coca plots, portend the greatest hazard to amphibian populations. The entire production cycle of cocaine has been linked to ecosystem degradation. The clearing of pristine forests for coca propagation in Colombia is well documented, and some of these regions coincide with those that contain exceptional amphibian biodiversity. This is particularly problematic as coca production encroaches more deeply into more remote areas of tropical rain forest. Transportation of disease, including the chitrid fungus, to these remote regions via human intrusion may also adversely affect amphibian populations. Therefore, the cumulative impacts of coca production, through habitat destruction, application of agrochemicals, and potential transmission of disease, are judged to pose greater risks to amphibian populations in coca-growing regions than the glyphosate spray control program.

  16. Susceptibility of the leaf-eating beetle, Galerucella calmariensis, a biological control agent for purple loosestrife (Lythrum salcaria), to three mosquito control larvicides

    USGS Publications Warehouse

    Lowe, T.P.; Hershberger, T.D.

    2004-01-01

    We evaluated the susceptibility of Galerucella calmariensis, a species used to control purple loosestrife (Lythrum salicaria), to three mosquito control larvicides. Larvae and adults were fed loosestrife cuttings dipped in Abate? (3.75 g?L-1) was reduced significantly and survival was significantly lower among larvae and adults eating cuttings dipped in Abate (>0.17 g?L-1 and >2.27 g?L-1, respectively). Hatching success of eggs dipped in Altosid (>2.52 g?L-1) was reduced significantly. With exposure to Altosid, larval survival to pupation and adult emergence was reduced significantly at concentrations of >2.92 g?L-1 and >0.63 g?L-1, respectively. Altosid (>0.23 g?L-1) also delayed the onset of pupation and adult emergence among larvae that survived to pupate. Larvae that survived with exposure to Altosid (>1.72 g?L-1) grew to 70% larger than those exposed to lower concentrations. Pupal survival was unaffected with exposure to Abate and Altosid and adult survival was unaffected with exposure to Altosid. Bacillus thuringiensis var israeliensis did not adversely affect any life stage of G. calmariensis. The mean Abate concentration on cuttings exposed to operational spraying was in the range that reduced egg hatchability and adult survival but was higher than concentrations that caused complete mortality of larvae. The mean Altosid concentration on cuttings exposed to operational spraying was in the range that reduced hatching success in eggs and delayed pupation and adult emergence of larvae.

  17. Program for plasma-sprayed self-lubricating coatings

    NASA Technical Reports Server (NTRS)

    Walther, G. C.

    1979-01-01

    A method for preparing composite powders of the three coating components was developed and a procedure that can be used in applying uniform coatings of the composite powders was demonstrated. Composite powders were prepared by adjusting particle sizes of the components and employing a small amount of monoaluminum phosphate as an inorganic binder. Quantitative microscopy (image analysis) was found to be a convenient method of characterizing the composition of the multiphase plasma-sprayed coatings. Area percentages and distribution of the components were readily obtained by this method. The adhesive strength of the coating to a nickel-chromium alloy substrate was increased by about 40 percent by a heat treatment of 20 hours at 650 C.

  18. Inputs of the Dormant-Spray Pesticide, Diazinon, to the San Joaquin River, California, February 1993

    USGS Publications Warehouse

    Domagalski, Joseph L.; Dubrovsky, Neil M.; Kratzer, Charles R.

    1995-01-01

    INTRODUCTION The objective of the National Water Quality Assessment (NAWQA) Program of the U.S. Geological Survey is to describe the status and trends of the Nation's water quality with respect to natural features of the environment and human activities or land-use. Pesticides are a major water-quality issue in the San Joaquin Valley of California (fig. 1), and pesticide residues may be transported to rivers and streams in agricultural runoff following winter storms. Three sites in the western San Joaquin Valley were monitored during and after two February 1993 storms. The storms occurred after extensive spraying of organophosphate insecticides, mostly diazinon, on almond and other stone-fruit orchards.

  19. Analysis of DuPont and Kodak duplicating films and chemistries in a Fultron spray processor

    NASA Technical Reports Server (NTRS)

    Weinstein, M. S.

    1972-01-01

    A test program was conducted with duPont duplicating film type SR 112 and SCOLOR developer and Kodak duplicating film types 2430, 2422, and FE 2628 (SO-467) and MX-641 developer to determine sensitometric and image quality characteristics of these materials when used with a fultron spray processor. The test results show that the SCOLOR developer foams excessively in the fultron processor when used with or without the addition of an antifoaming agent. The Kodak type FE 2628 film with MX-641 chemistry had the longest linear Log E range at a 1.0 gamma. Sensitometric curves and granularity traces for all film process combinations tested are included.

  20. Large-Diameter Sewer Rehabilitation Using a Spray-Applied Fiber-Reinforced Geopolymer Mortar

    EPA Science Inventory

    In order to assist the utilities in making well informed maintenance decisions, the U.S. Environmental Protection Agency (EPA) has developed an innovative technology demonstration program to evaluate technologies that have the potential to reduce costs and increase the effectiven...

  1. 40 CFR 170.103 - Exceptions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 23 2010-07-01 2010-07-01 false Exceptions. 170.103 Section 170.103 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) PESTICIDE PROGRAMS WORKER PROTECTION... squirt,” “frill and spray,” chemigation, soil-incorporation, or soil-injection; (f) In a manner not...

  2. Reversal of overdose on fentanyl being illicitly sold as heroin with naloxone nasal spray: A case report.

    PubMed

    Fareed, Ayman; Buchanan-Cummings, Ann Marie; Crampton, Kelli; Grant, Angela; Drexler, Karen

    2015-08-01

    This is a case report describing a reversal of fentanyl overdose with naloxone nasal spray. The patient was not aware that he overdosed on fentanyl being sold as heroin. The Veterans Health Administration (VHA) has implemented an initiative to provide education for veterans, their families, friends and significant others about opioid overdose and use of naloxone reversal kits. The Atlanta VA Medical Center adopted this program to reduce the risk of opioid overdose in high risk patients. Over the past year, we provided educational sessions for 63 veterans and their families. We also prescribed 41 naloxone kits. We have received three reports of opioid overdose reversal with use of naloxone kits prescribed by the Atlanta VA Medical Center. The authors recommend that public health administrators and policy makers advocate for the implementation of these programs to reduce the rising number of overdose death in the United States and worldwide. © American Academy of Addiction Psychiatry.

  3. Attachment techniques for high temperature strain

    NASA Astrophysics Data System (ADS)

    Wnuk, Steve P., Jr.

    1993-01-01

    Attachment methods for making resistive strain measurements to 2500 F were studied. A survey of available strain gages and attachment techniques was made, and the results are compiled for metal and carbon composite test materials. A theoretical analysis of strain transfer into a bonded strain gage was made, and the important physical parameters of the strain transfer medium, the ceramic matrix, were identified. A pull tester to measure pull-out tests on commonly used strain gage cements indicated that all cements tested displayed adequate strength for good strain transfer. Rokide flame sprayed coatings produced significantly stronger bonds than ceramic cements. An in-depth study of the flame spray process produced simplified installation procedures which also resulted in greater reliability and durability. Application procedures incorporating improvements made during this program are appended to the report. Strain gages installed on carbon composites, Rene' 41, 316 stainless steel, and TZM using attachment techniques developed during this program were successfully tested to 2500 F. Photographs of installation techniques, test procedures, and graphs of the test data are included in this report.

  4. Development of low modulus material for use in ceramic gas path seal applications

    NASA Technical Reports Server (NTRS)

    Eaton, H. E.; Novak, R. C.

    1981-01-01

    Three candidate materials were examined: Brunsbond (R) Pad; plasma sprayed porous NiCrAlY; and plasma sprayed low modulus microcracked zirconia. Evaluation consisted of mechanical, thermophysical, and oxidation resistance testing along with optical microscopy and a feasibility demonstration of attaching the material to a suitable substrate. The goals of the program were the following: feasibility of fastening or depositing the low modulus system onto a broad range of substrate alloys; feasibility of depositing or forming the low modulus system to a thickness of 0.19 cm to 0.38 cm; potential to attain a modulus of elasticity in the range of 3.4 to 6.9 GPa (0.5 to 1.0 MSI), and an ultimate strength of 17.2 MPa (2.5 ksi); suitable thermal conductivity; and static oxidation life of at least 1000 hours at 1311 K. The results of the program indicate that all three systems offer attractive properties as a strain isolator material.

  5. Insecticidal Suppression of Asian Citrus Psyllid Diaphorina citri (Hemiptera: Liviidae) Vector of Huanglongbing Pathogens

    PubMed Central

    Qureshi, Jawwad A.; Kostyk, Barry C.; Stansly, Philip A.

    2014-01-01

    Diaphorina citri vectors pathogens that cause ‘huanglongbing’ or citrus greening disease which poses a serious threat to citrus production worldwide. Vector suppression is critical to reduce disease spread. Efficacy is a main concern when choosing an insecticide. Insecticidal treatments of 49 products or 44 active ingredients (a.i) labeled or experimental were field tested between 2005–2013 as foliar sprays (250 treatments, 39 a.i) or soil applications (47 treatments, 9 a.i) to control D. citri in citrus. A combined effect of nymphal and adult suppression in response to sprays of 23 insecticides representing 9 modes of action (MoA) groups and 3 unknown MoA provided more than 90% reduction of adult D. citri over 24–68 days. Observable effects on nymphs were generally of shorter duration due to rapid maturation of flush. However, reduction of 76–100% nymphs or adults over 99–296 days was seen on young trees receiving drenches of the neonicotinoids imidacloprid, thiamethoxam or clothianidin (MoA 4A) and a novel anthranilic diamide, cyantraniliprole (MoA 28). Effective products identified for foliar sprays to control D. citri provide sufficient MoA groups for rotation to delay evolution of insecticide resistance by D. citri and other pests. However, cyantraniliprole is now the only available alternative for rotation with neonicotinoids in soil application to young trees. Sprays of up to eight of the most effective insecticides could be rotated over a year without repetition of any MoA and little or no recourse to neonicotinoids or cyantraniliprole, so important for protection of young trees. Other considerations effecting decisions of what and when to spray include prevalence of huanglongbing, pest pressure, pre-harvest intervals, overall budget, equipment availability, and conservation of beneficial arthropods. Examples of spray programs utilizing broad-spectrum and relatively selective insecticides are provided to improve vector management and may vary depending on individual or regional assessment of all factors. PMID:25437858

  6. Insecticidal suppression of Asian citrus psyllid Diaphorina citri (Hemiptera: Liviidae) vector of huanglongbing pathogens.

    PubMed

    Qureshi, Jawwad A; Kostyk, Barry C; Stansly, Philip A

    2014-01-01

    Diaphorina citri vectors pathogens that cause 'huanglongbing' or citrus greening disease which poses a serious threat to citrus production worldwide. Vector suppression is critical to reduce disease spread. Efficacy is a main concern when choosing an insecticide. Insecticidal treatments of 49 products or 44 active ingredients (a.i) labeled or experimental were field tested between 2005-2013 as foliar sprays (250 treatments, 39 a.i) or soil applications (47 treatments, 9 a.i) to control D. citri in citrus. A combined effect of nymphal and adult suppression in response to sprays of 23 insecticides representing 9 modes of action (MoA) groups and 3 unknown MoA provided more than 90% reduction of adult D. citri over 24-68 days. Observable effects on nymphs were generally of shorter duration due to rapid maturation of flush. However, reduction of 76-100% nymphs or adults over 99-296 days was seen on young trees receiving drenches of the neonicotinoids imidacloprid, thiamethoxam or clothianidin (MoA 4A) and a novel anthranilic diamide, cyantraniliprole (MoA 28). Effective products identified for foliar sprays to control D. citri provide sufficient MoA groups for rotation to delay evolution of insecticide resistance by D. citri and other pests. However, cyantraniliprole is now the only available alternative for rotation with neonicotinoids in soil application to young trees. Sprays of up to eight of the most effective insecticides could be rotated over a year without repetition of any MoA and little or no recourse to neonicotinoids or cyantraniliprole, so important for protection of young trees. Other considerations effecting decisions of what and when to spray include prevalence of huanglongbing, pest pressure, pre-harvest intervals, overall budget, equipment availability, and conservation of beneficial arthropods. Examples of spray programs utilizing broad-spectrum and relatively selective insecticides are provided to improve vector management and may vary depending on individual or regional assessment of all factors.

  7. Flame Spray Strain Gages with Improved Durability and Lifetimes

    NASA Technical Reports Server (NTRS)

    Fralick, Gustave (Technical Monitor); Gregory, Otto

    2003-01-01

    The focus of this APP research program was to improve the bond coats used in the fabrication of flame sprayed instrumentation. Typically. a bond coat is applied to a superalloy surface prior to the application of a thin dielectric coating onto which instrumentation is placed. After affixing the instrumentation, a much thicker ceramic topcoat is typically applied to protect the instrumentation from harsh environments. The fatigue life of NiCoCrAlY coated superalloys was extended beyond current state-of-the-art by relatively simple and cost effective means. Heat treatment in reduced oxygen partial pressures at 1750 to 1800 F effectively doubled the fatigue life of NiCoCrAlY coated substrates relative to as-sprayed substrates and when used in conjunction with platinum diffusion barriers yielded a four fold increase in the fatigue life of NiCoCrAlY coated substrates. Further improvements in the fatigue life of thermally sprayed coatings were made by employing intermediate coatings, which minimized thermal expansion differences between the bond coat and top coat. Combinatorial chemistry experiments yielded an optimum composition for an intermediate TCE matching coating that showed considerable promise in extending the fatigue life of thermal spray instrumentation. The intermediate coating had two functions: to reduce the surface roughness of the peaks and valleys associated with the as-sprayed NiCoCrAlY bond coat, and to produce a thin layer of a mixture of Al2O3 and NiCoCrAlY that exhibited an intermediate TCE. The optimal composition of the intermediate coating consisted of 60 wt% Al2O3 and 40 wt% NiCoCrAlY, as determined by energy dispersive analysis of x-rays (EDS). Intermediate coatings having this composition were prepared by physical vapor deposition and the resulting coating systems are being evaluated in our test facility.

  8. Comparison of the performance between a spray gun and a spray boom in ornamentals.

    PubMed

    Foqué, D; Nuyttens, D

    2011-01-01

    Flemish greenhouse growers predominantly use handheld spray guns and spray lances for their crop protection purposes although these techniques are known for their heavy workload and their high operator exposure risks. Moreover, when these techniques are compared with spray boom equipment, they are often found to be less effective. On the other hand, handheld spraying techniques are less expensive and more flexible to use. Additionally, many Flemish growers are convinced that a high spray volume and spray pressure is needed to assure a good plant protection. The aim of this work was to evaluate and compare the spray deposition, penetration and uniformity between a manually pulled horizontal spray boom and a spray gun under controlled laboratory conditions. In total, six different spray application techniques were evaluated. In general, the total deposition results were comparable between the spray boom and the spray gun applications but the boom applications resulted in a more uniform spray distribution over the crop. On a plant level, the spray distribution was not uniform for the different techniques with highest deposits on the upper side of the top leaves. Using spray guns at a higher spray pressure did not improve spray penetration and deposition on the bottom side of the leaves. From the different nozzle types, the XR 80 03 gave the best results. Plant density clearly affected crop penetration and deposition on the bottom side of the leaves.

  9. Liquid Fertilizer Spraying Performance Using A Knapsack Power Sprayer On Soybean Field

    NASA Astrophysics Data System (ADS)

    Gatot, P.; Anang, R.

    2018-05-01

    An effort for increasing soybean production can be conducted by applying liquid fertilizer on soybean cultivation field. The objective of this research was to determine liquid fertilizer spraying performance using knapsack power sprayer TASCO TF-900 on a soybean cultivation field. Performances test were conducted in the Laboratory of Spraying Test and on a soybean cultivation field to determine (1) effective spraying width, (2) droplets diameter, (3) droplets density, (4) effective spraying discharge rate, and (5) effective field capacity of spraying. The research was conducted using 2 methods: (1) one-nozzle spraying, and (2) four- nozzles spraying. Results of the research showed that at a constant pressure of 900 kPa effective spraying width using one-nozzle spraying and four-nozzles spraying were 0.62 m and 1.10 m. A bigger effective spraying width was resulted in a bigger average effective spraying discharge rate and average effective spraying field capacity of 4.52 l/min and 83.92 m2/min on forward walking speed range of 0.94 m/s up to 1.77 m/s. On the contrary, bigger effective spraying width was result in bigger droplets diameter of 502.73 μm and a smaller droplets density of 98.39 droplets/cm2, whereas smaller effective spraying width was resulted in a smaller droplets diameter of 367.09 μm and a bigger droplets density of 350.53 droplets/cm2. One-nozzle spraying method produced a better spraying quality than four-nozzles spraying method, although four-nozzles spraying was resulted in a bigger effective field capacity of spraying.

  10. Toxic Epidemics: Agent Orange Sickness in Vietnam and the United States.

    PubMed

    Uesugi, Tak

    2016-01-01

    Social scientists studying toxic epidemics have often endeavored to shed light on the differences between scientists' and nonscientists' epistemic perspectives. Yet, little attention has been paid to the processes through which a toxic epidemic emerges as a phenomenon. A Luoi Valley of Central Vietnam was extensively sprayed with chemical defoliants (including Agent Orange) during the Vietnam War. The latent toxic effects of these chemicals, however, went largely unnoticed until the late 1990s. By juxtaposing the history through which the notion of "Agent Orange Sickness" emerged in the United States with an ethnographic study of A Luoi, I explore the notion of poison under which Agent Orange became recognizable as a poison.

  11. Tank Investigation of the EDO Model 142 Hydro-Ski Research Airplane

    NASA Technical Reports Server (NTRS)

    Ramsen, John A.; Wadlin, Kenneth L.; Gray, George R.

    1951-01-01

    A tank investigation has been conducted of a 1/10-size powered-dynamic model of the Edo model 142 hydra-ski research airplane. The results of tests of two configurations are presented: One included a large ski and a ski well; the other, a small ski without a well. Water take-offs would be possible with the available thrust for either configuration: however, the configuration with the large ski emerged sooner and had less resistance from ski emergence until take-off. Longitudinal stability and landing behavior in smooth water were satisfactory for both configurations. Some alteration to the design of the tail would be desirable in order to reduce the spray loads.

  12. Comparison of the Characteristics and Performance of Flurbiprofen 8.75 mg Spray for Sore Throat.

    PubMed

    Veale, David; Shephard, Adrian; Adams, Verity; Lidster, Charlotte

    2017-01-01

    Sore throat sprays provide targeted relief by delivering the active ingredient directly to the site of pain. Different sprays vary in characteristics, thus affecting delivery of the active ingredient to the throat, which can impact compliance. The characteristics and performance of FLURBIPROFEN 8.75 mg SPRAY were compared with 12 other sprays. Parameters assessed included spray angle and pattern, droplet size distribution, shot weight uniformity and shot weight throughout life. Among all sprays tested WICK Sulagil Halsspray had the smallest spray angle (46°) and also the smallest diameter spray pattern (X=32.8 mm; Y=34.4 mm). Thiovalone® Buccal Spray Suspension had both the largest spray angle (82°) and largest diameter spray pattern (X=62.6 mm; Y=78.0 mm). Hasco Sept® Aerosol Spray had the smallest droplet size (Dv90=118.4 μm) whereas OKi infiammazione e dolore® 0.16% spray had the largest (Dv90=214.34 μm). In terms of shot weight uniformity, TANTUM® VERDE GOLA 0.25% spray showed the least variation (2% RSD) between shots and UNIBEN Aerosol Spray the most (23.4% RSD). Shot weight throughout life studies showed that FLURBIPROFEN 8.75 mg SPRAY had the least deviation from shot weight (1.77%) whereas OKi infiammazione e dolore® 0.16% spray deviated the most (44.9%). FLURBIPROFEN 8.75 mg SPRAY had the second smallest spray angle/pattern and droplet size distribution and also the least variation in shot weight. Different sore throat sprays vary in different attributes, affecting delivery of the active ingredient. FLURBIPROFEN 8.75 mg SPRAY performed well overall, ranking first among all sprays tested, and providing a dose which is targeted and uniformly delivered throughout the life of the bottle. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  13. The Pharmacokinetics of Atomized Lidocaine Administered via the Trachea: A Randomized Trial.

    PubMed

    Takaenoki, Yumiko; Masui, Kenichi; Oda, Yutaka; Kazama, Tomiei

    2016-07-01

    Under emergent conditions, endotracheal drug administration may be an effective method of delivering emergency drugs. A common technique is to administer these drugs using a nonatomized spray. Atomized drug delivery may be an attractive alternative to nonatomized delivery because atomized particles are small, cover a large surface area, and may better adhere to endotracheal membrane resulting in more effective drug absorption. In this study, we compared the pharmacokinetic profile of lidocaine administered into the trachea using an atomized or a nonatomized technique. Twenty patients were anesthetized using propofol and remifentanil. Ten minutes after rocuronium was administered, patients received 4% lidocaine (2 mg/kg) intratracheally over 2 seconds before tracheal intubation. Ten patients received atomized lidocaine using a mucosal atomization device, and the other 10 patients received nonatomized lidocaine using a traditional spray tube. Arterial lidocaine plasma concentrations were measured before; at 1, 3, 5, 7, 10, 15, 20, 30, 45, and 60 minutes; and then every 60 minutes after the administration of lidocaine until the end of the operation. We developed a pharmacokinetic model to examine whether bioavailability or absorption rate was different between atomized versus nonatomized lidocaine administration. The total body clearance was fixed at a published value to determine the bioavailability. Peak plasma concentrations were larger using the mucosal atomization device (median [range]: 1.9 [1.4-3.2] μg/mL) than the spray tube (1.1 [0.6-2.0] μg/mL; P = 0.0021). Our pharmacokinetic model estimated a difference of bioavailability between the atomized and the nonatomized lidocaine (0.801 and 0.559 respectively, P = 0.0005), whereas our model estimated no difference in the absorption rate constant (0.00688/min). Our results suggest that when using atomized delivery of lidocaine, less drug is required to achieve a near equivalent plasma lidocaine concentration. Atomized drug administration may be a more efficient method for endotracheal drug administration.

  14. Experimental investigation on the characteristics of supersonic fuel spray and configurations of induced shock waves.

    PubMed

    Wang, Yong; Yu, Yu-Song; Li, Guo-Xiu; Jia, Tao-Ming

    2017-01-05

    The macro characteristics and configurations of induced shock waves of the supersonic sprays are investigated by experimental methods. Visualization study of spray shape is carried out with the high-speed camera. The macro characteristics including spray tip penetration, velocity of spray tip and spray angle are analyzed. The configurations of shock waves are investigated by Schlieren technique. For supersonic sprays, the concept of spray front angle is presented. Effects of Mach number of spray on the spray front angle are investigated. The results show that the shape of spray tip is similar to blunt body when fuel spray is at transonic region. If spray entered the supersonic region, the oblique shock waves are induced instead of normal shock wave. With the velocity of spray increasing, the spray front angle and shock wave angle are increased. The tip region of the supersonic fuel spray is commonly formed a cone. Mean droplet diameter of fuel spray is measured using Malvern's Spraytec. Then the mean droplet diameter results are compared with three popular empirical models (Hiroyasu's, Varde's and Merrigton's model). It is found that the Merrigton's model shows a relative good correlation between models and experimental results. Finally, exponent of injection velocity in the Merrigton's model is fitted with experimental results.

  15. Experimental investigation on the characteristics of supersonic fuel spray and configurations of induced shock waves

    PubMed Central

    Wang, Yong; Yu, Yu-song; Li, Guo-xiu; Jia, Tao-ming

    2017-01-01

    The macro characteristics and configurations of induced shock waves of the supersonic sprays are investigated by experimental methods. Visualization study of spray shape is carried out with the high-speed camera. The macro characteristics including spray tip penetration, velocity of spray tip and spray angle are analyzed. The configurations of shock waves are investigated by Schlieren technique. For supersonic sprays, the concept of spray front angle is presented. Effects of Mach number of spray on the spray front angle are investigated. The results show that the shape of spray tip is similar to blunt body when fuel spray is at transonic region. If spray entered the supersonic region, the oblique shock waves are induced instead of normal shock wave. With the velocity of spray increasing, the spray front angle and shock wave angle are increased. The tip region of the supersonic fuel spray is commonly formed a cone. Mean droplet diameter of fuel spray is measured using Malvern’s Spraytec. Then the mean droplet diameter results are compared with three popular empirical models (Hiroyasu’s, Varde’s and Merrigton’s model). It is found that the Merrigton’s model shows a relative good correlation between models and experimental results. Finally, exponent of injection velocity in the Merrigton’s model is fitted with experimental results. PMID:28054555

  16. Hidden Sylvatic Foci of the Main Vector of Chagas Disease Triatoma infestans: Threats to the Vector Elimination Campaign?

    PubMed Central

    Schachter-Broide, Judith; Dujardin, Jean-Pierre; Dotson, Ellen M.; Kitron, Uriel; Gürtler, Ricardo E.

    2011-01-01

    Background Establishing the sources of reinfestation after residual insecticide spraying is crucial for vector elimination programs. Triatoma infestans, traditionally considered to be limited to domestic or peridomestic (abbreviated as D/PD) habitats throughout most of its range, is the target of an elimination program that has achieved limited success in the Gran Chaco region in South America. Methodology/Principal Findings During a two-year period we conducted semi-annual searches for triatomine bugs in every D/PD site and surrounding sylvatic habitats after full-coverage spraying of pyrethroid insecticides of all houses in a well-defined rural area in northwestern Argentina. We found six low-density sylvatic foci with 24 T. infestans in fallen or standing trees located 110–2,300 m from the nearest house or infested D/PD site detected after insecticide spraying, when house infestations were rare. Analysis of two mitochondrial gene fragments of 20 sylvatic specimens confirmed their species identity as T. infestans and showed that their composite haplotypes were the same as or closely related to D/PD haplotypes. Population studies with 10 polymorphic microsatellite loci and wing geometric morphometry consistently indicated the occurrence of unrestricted gene flow between local D/PD and sylvatic populations. Mitochondrial DNA and microsatellite sibship analyses in the most abundant sylvatic colony revealed descendents from five different females. Spatial analysis showed a significant association between two sylvatic foci and the nearest D/PD bug population found before insecticide spraying. Conclusions Our study shows that, despite of its high degree of domesticity, T. infestans has sylvatic colonies with normal chromatic characters (not melanic morphs) highly connected to D/PD conspecifics in the Argentinean Chaco. Sylvatic habitats may provide a transient or permanent refuge after control interventions, and function as sources for D/PD reinfestation. The occurrence of sylvatic foci of T. infestans in the Gran Chaco may pose additional threats to ongoing vector elimination efforts. PMID:22039559

  17. 10 CFR 431.261 - Purpose and scope.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Purpose and scope. 431.261 Section 431.261 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN COMMERCIAL AND INDUSTRIAL EQUIPMENT Commercial Prerinse Spray Valves § 431.261 Purpose and scope. This subpart contains energy...

  18. GENERIC VERIFICATION PROTOCOL FOR THE VERIFICATION OF PESTICIDE SPRAY DRIFT REDUCTION TECHNOLOGIES FOR ROW AND FIELD CROPS

    EPA Science Inventory

    This ETV program generic verification protocol was prepared and reviewed for the Verification of Pesticide Drift Reduction Technologies project. The protocol provides a detailed methodology for conducting and reporting results from a verification test of pesticide drift reductio...

  19. 10 CFR 431.266 - Energy conservation standards and their effective dates.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Energy conservation standards and their effective dates. 431.266 Section 431.266 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN COMMERCIAL AND INDUSTRIAL EQUIPMENT Commercial Prerinse Spray Valves Energy Conservation Standards...

  20. 10 CFR 431.266 - Energy conservation standards and their effective dates.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 3 2012-01-01 2012-01-01 false Energy conservation standards and their effective dates. 431.266 Section 431.266 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN COMMERCIAL AND INDUSTRIAL EQUIPMENT Commercial Prerinse Spray Valves Energy Conservation Standards...

  1. 10 CFR 431.266 - Energy conservation standards and their effective dates.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 3 2014-01-01 2014-01-01 false Energy conservation standards and their effective dates. 431.266 Section 431.266 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN COMMERCIAL AND INDUSTRIAL EQUIPMENT Commercial Prerinse Spray Valves Energy Conservation Standards...

  2. 10 CFR 431.266 - Energy conservation standards and their effective dates.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 3 2011-01-01 2011-01-01 false Energy conservation standards and their effective dates. 431.266 Section 431.266 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN COMMERCIAL AND INDUSTRIAL EQUIPMENT Commercial Prerinse Spray Valves Energy Conservation Standards...

  3. Evaluating an Action Threshold-Based Insecticide Program on Onion Cultivars Varying in Resistance to Onion Thrips (Thysanoptera: Thripidae).

    PubMed

    Nault, Brian A; Huseth, Anders S

    2016-08-01

    Onion thrips, Thrips tabaci Lindeman (Thysanoptera: Thripidae), is a highly destructive pest of onion, Allium cepa L., and its management relies on multiple applications of foliar insecticides. Development of insecticide resistance is common in T. tabaci populations, and new strategies are needed to relax existing levels of insecticide use, but still provide protection against T. tabaci without compromising marketable onion yield. An action threshold-based insecticide program combined with or without a thrips-resistant onion cultivar was investigated as an improved approach for managing T. tabaci infestations in commercial onion fields. Regardless of cultivar type, the average number of insecticide applications needed to manage T. tabaci infestations in the action-threshold based program was 4.3, while the average number of sprays in the standard weekly program was 7.2 (a 40% reduction). The mean percent reduction in numbers of applications following the action threshold treatment in the thrips-resistant onion cultivar, 'Advantage', was 46.7% (range 40-50%) compared with the standard program, whereas the percentage reduction in applications in action threshold treatments in the thrips-susceptible onion cultivar, 'Santana', was 34.3% (range 13-50%) compared with the standard program, suggesting a benefit of the thrips-resistant cultivar. Marketable bulb yields for both 'Advantage' and 'Santana' in the action threshold-based program were nearly identical to those in the standard program, indicating that commercially acceptable bulb yields will be generated with fewer insecticide sprays following an action threshold-based program, saving money, time and benefiting the environment. © The Authors 2016. Published by Oxford University Press on behalf of Entomological Society of America. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  4. Computation of Reacting Flows in Combustion Processes

    NASA Technical Reports Server (NTRS)

    Keith, Theo G., Jr.; Chen, Kuo-Huey

    1997-01-01

    The main objective of this research was to develop an efficient three-dimensional computer code for chemically reacting flows. The main computer code developed is ALLSPD-3D. The ALLSPD-3D computer program is developed for the calculation of three-dimensional, chemically reacting flows with sprays. The ALL-SPD code employs a coupled, strongly implicit solution procedure for turbulent spray combustion flows. A stochastic droplet model and an efficient method for treatment of the spray source terms in the gas-phase equations are used to calculate the evaporating liquid sprays. The chemistry treatment in the code is general enough that an arbitrary number of reaction and species can be defined by the users. Also, it is written in generalized curvilinear coordinates with both multi-block and flexible internal blockage capabilities to handle complex geometries. In addition, for general industrial combustion applications, the code provides both dilution and transpiration cooling capabilities. The ALLSPD algorithm, which employs the preconditioning and eigenvalue rescaling techniques, is capable of providing efficient solution for flows with a wide range of Mach numbers. Although written for three-dimensional flows in general, the code can be used for two-dimensional and axisymmetric flow computations as well. The code is written in such a way that it can be run in various computer platforms (supercomputers, workstations and parallel processors) and the GUI (Graphical User Interface) should provide a user-friendly tool in setting up and running the code.

  5. Potential theory of radiation

    NASA Technical Reports Server (NTRS)

    Chiu, Huei-Huang

    1989-01-01

    A theoretical method is being developed by which the structure of a radiation field can be predicted by a radiation potential theory, similar to a classical potential theory. The introduction of a scalar potential is justified on the grounds that the spectral intensity vector is irrotational. The vector is also solenoidal in the limits of a radiation field in complete radiative equilibrium or in a vacuum. This method provides an exact, elliptic type equation that will upgrade the accuracy and the efficiency of the current CFD programs required for the prediction of radiation and flow fields. A number of interesting results emerge from the present study. First, a steady state radiation field exhibits an optically modulated inverse square law distribution character. Secondly, the unsteady radiation field is structured with two conjugate scalar potentials. Each is governed by a Klein-Gordon equation with a frictional force and a restoring force. This steady potential field structure and the propagation of radiation potentials are consistent with the well known results of classical electromagnetic theory. The extension of the radiation potential theory for spray combustion and hypersonic flow is also recommended.

  6. Effect of spray angle and spray volume on deposition of a medium droplet spray with air support in ivy pot plants.

    PubMed

    Foqué, Dieter; Pieters, Jan G; Nuyttens, David

    2014-03-01

    Spray boom systems, an alternative to the predominantly-used spray guns, have the potential to considerably improve crop protection management in glasshouses. Based on earlier experiments, the further optimization of the deposits of a medium spray quality extended range flat fan nozzle type using easy adjustable spray boom settings was examined. Using mineral chelate tracers and water sensitive papers, the spray results were monitored at three plant levels, on the upper side and the underside of the leaves, and on some off-target collectors. In addition, the deposition datasets of all tree experiments were compared. The data showed that the most efficient spray distribution with the medium spray quality flat fan nozzles was found with a 30° forward angled spray combined with air support and an application rate of 1000 L ha(-1) . This technique resulted in a more uniform deposition in the dense canopy and increased spray deposition on the lower side of the leaves compared with the a standard spray boom application. Applying 1000 L ha(-1) in two subsequent runs instead of one did not seem to show any added value. Spray deposition can be improved hugely simply by changing some spray boom settings like nozzle type, angling the spray, using air support and adjusting the spray volume to the crop. © 2013 Society of Chemical Industry.

  7. Effect of spray application technique on spray deposition in greenhouse strawberries and tomatoes.

    PubMed

    Braekman, Pascal; Foque, Dieter; Messens, Winy; Van Labeke, Marie-Christine; Pieters, Jan G; Nuyttens, David

    2010-02-01

    Increasingly, Flemish greenhouse growers are using spray booms instead of spray guns to apply plant protection products. Although the advantages of spray booms are well known, growers still have many questions concerning nozzle choice and settings. Spray deposition using a vertical spray boom in tomatoes and strawberries was compared with reference spray equipment. Five different settings of nozzle type, size and pressure were tested with the spray boom. In general, the standard vertical spray boom performed better than the reference spray equipment in strawberries (spray gun) and in tomatoes (air-assisted sprayer). Nozzle type and settings significantly affected spray deposition and crop penetration. Highest overall deposits in strawberries were achieved using air-inclusion or extended-range nozzles. In tomatoes, the extended-range nozzles and the twin air-inclusion nozzles performed best. Using smaller-size extended-range nozzles above the recommended pressure range resulted in lower deposits, especially inside the crop canopy. The use of a vertical spray boom is a promising technique for applying plant protection products in a safe and efficient way in tomatoes and strawberries, and nozzle choice and setting should be carefully considered.

  8. Improved Orifice Plate for Spray Gun

    NASA Technical Reports Server (NTRS)

    Cunningham, W.

    1986-01-01

    Erratic spray pattern of commercial spray gun changed to repeatable one by simple redesign of two parts. In modified spray gun orifice plate and polytetrafluoroethylene bushing redesigned to assure centering and alignment with nozzle. Such improvement useful in many industrial applications requiring repeatable spray patterns. Might include spraying of foam insulation, paint, other protective coatings, detergents, abrasives, adhesives, process chemicals, or fuels. Unmodified spray gun produces erratic spray because lateral misalignment between orifice plate and nozzle.

  9. Ocular injury with high-pressure paint: a case report.

    PubMed

    Bandyopadhyay, Chitrabhanu; Mitra, Arjit; Harrison, Rosalind J

    2009-01-01

    Chemical injury to the eye is an ophthalmic emergency that can be caused by a work-related accident or common household products. Uradil SZ261 G3Z-65 is a resin containing butyl gycol (2-butoxyethanol) and ethyl ethanol amine (2-dimethyaminoethanol). It is used in stoving enamels for interior and exterior use. The authors report a case of ocular surface injury with a highpressure industrial spray paint-Waterborne Stoving Gentian Blue containing Uradil.

  10. CCP Boeing/ULA Crew Access Arm Emergency Evacuation Water Test

    NASA Image and Video Library

    2016-03-23

    Water sprays on the Crew Access Arm during a deluge systems test March 23 at a construction yard near NASA's Kennedy Space Center in Florida. The arm is being tested before being installed on Space Launch Complex 41 Crew Access Tower later this year. It will be used as a bridge by astronauts to board Boeing's CST-100 Starliner spacecraft as it stands on the launch pad atop a United Launch Alliance Atlas V rocket.

  11. Phenology prediction component of GypsES

    Treesearch

    Jesse A. Logan; Lukas P. Schaub; F. William Ravlin

    1991-01-01

    Prediction of phenology is an important component of most pest management programs, and considerable research effort has been expended toward development of predictive tools for gypsy moth phenology. Although phenological prediction is potentially valuable for timing of spray applications (e.g. Bt, or Gypcheck) and other management activities (e.g. placement and...

  12. Unification of the macro- and microbiome in trophic ecology

    USDA-ARS?s Scientific Manuscript database

    Biological control is a key part of virtually any IPM program, and microbial bio-control agents represent particularly effective agents because of their capacity to be applied via conventional spray application methods. We are showing that fungi function just as arthropods do in the food web—the fun...

  13. Enhancing extension recommendations to maximize efficacy of spray programs for the Georgia DOT : final report.

    DOT National Transportation Integrated Search

    2015-12-23

    Research was conducted to evaluate equipment, adjuvants, and water quality used by the : Georgia DOT on herbicide efficacy for roadside management. From 19 DOT stations, 68% had alkaline : (7.1 to 7.9) water, 32% had hard water (>120 ppm), and 10% ha...

  14. 78 FR 62970 - Energy Conservation Program for Consumer Products and Certain Commercial and Industrial Equipment...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-10-23

    ... of showerhead and hand-held showerhead; removal of body sprays from the proposed showerhead... standardized test method to be used when verifying the mechanical retention of a showerhead flow control insert... Faucets 1. Definitions 2. Test Procedure for Showerhead Flow Control Insert [[Page 62971

  15. 77 FR 31742 - Energy Conservation Program for Consumer Products and Certain Commercial and Industrial Equipment...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-30

    .... Test Procedure for Commercial Prerinse Spray Valves 4. Design Requirements for Showerheads 5... procedures prescribed or amended under this section shall be reasonably designed to produce test results...] American Society for Testing and Materials [ASTM] Standard F2324, entitled `Standard Test Method for Pre...

  16. Unravelling the bioherbicide potential of Eucalyptus globulus Labill: Biochemistry and effects of its aqueous extract

    PubMed Central

    Reigosa, Manuel J.; Valentão, Patrícia; Andrade, Paula B.

    2018-01-01

    In the worldwide search for new strategies in sustainable weed management, the use of plant species able to produce and release phytotoxic compounds into the environment could be an effective alternative to synthetic herbicides. Eucalyptus globulus Labill. is known to be a source of biologically active compounds responsible for its phytotoxic and allelopathic properties. Our previous results demonstrated the bioherbicide potential of eucalyptus leaves incorporated into the soil as a green manure, probably through the release of phytotoxins into the soil solution. Thus, the aims of this study were to understand the phytotoxicity of the eucalyptus leaves aqueous extract applied in pre- and post-emergence, and to identify and quantify its potentially phytotoxic water-soluble compounds. The effects were tested on the germination and early growth of the model target species Lactuca sativa and Agrostis stolonifera, and on physiological parameters of L. sativa adult plants after watering or spraying application. Dose-response curves and ED50 and ED80 values for eucalyptus aqueous extracts revealed pre-emergence inhibitory effects on both target species, effects being comparable to the herbicide metolachlor. While spraying treatment reduced the aerial and root biomass and increased the dry weight/fresh weight ratio of lettuce adult plants, watering application reduced protein contents and chlorophyll concentrations with respect to control, reflecting different modes of action depending on the site of phytotoxin entry. Via HPLC analyses, a total of 8 phenolic compounds (chlorogenic, two ρ-coumaric derivatives, ellagic, hyperoside, rutin, quercitrin, and kaempferol 3-O-glucoside) and other 5 low weight organic acids (citric, malic, shikimic, succinic and fumaric acids) were obtained from aqueous extract, the latter being identified for the first time in E. globulus. Despite some phytotoxic effects were found on lettuce adult plants, the use of eucalyptus aqueous extract would be discarded in post-emergence, whereas it was promising as a pre-emergence bioherbicide. PMID:29438430

  17. Unravelling the bioherbicide potential of Eucalyptus globulus Labill: Biochemistry and effects of its aqueous extract.

    PubMed

    Puig, Carolina G; Reigosa, Manuel J; Valentão, Patrícia; Andrade, Paula B; Pedrol, Nuria

    2018-01-01

    In the worldwide search for new strategies in sustainable weed management, the use of plant species able to produce and release phytotoxic compounds into the environment could be an effective alternative to synthetic herbicides. Eucalyptus globulus Labill. is known to be a source of biologically active compounds responsible for its phytotoxic and allelopathic properties. Our previous results demonstrated the bioherbicide potential of eucalyptus leaves incorporated into the soil as a green manure, probably through the release of phytotoxins into the soil solution. Thus, the aims of this study were to understand the phytotoxicity of the eucalyptus leaves aqueous extract applied in pre- and post-emergence, and to identify and quantify its potentially phytotoxic water-soluble compounds. The effects were tested on the germination and early growth of the model target species Lactuca sativa and Agrostis stolonifera, and on physiological parameters of L. sativa adult plants after watering or spraying application. Dose-response curves and ED50 and ED80 values for eucalyptus aqueous extracts revealed pre-emergence inhibitory effects on both target species, effects being comparable to the herbicide metolachlor. While spraying treatment reduced the aerial and root biomass and increased the dry weight/fresh weight ratio of lettuce adult plants, watering application reduced protein contents and chlorophyll concentrations with respect to control, reflecting different modes of action depending on the site of phytotoxin entry. Via HPLC analyses, a total of 8 phenolic compounds (chlorogenic, two ρ-coumaric derivatives, ellagic, hyperoside, rutin, quercitrin, and kaempferol 3-O-glucoside) and other 5 low weight organic acids (citric, malic, shikimic, succinic and fumaric acids) were obtained from aqueous extract, the latter being identified for the first time in E. globulus. Despite some phytotoxic effects were found on lettuce adult plants, the use of eucalyptus aqueous extract would be discarded in post-emergence, whereas it was promising as a pre-emergence bioherbicide.

  18. Program to develop sprayed, plastically deformable compressor shroud seal materials

    NASA Technical Reports Server (NTRS)

    Schell, J. D.; Schell, J. D.

    1980-01-01

    A study of fundamental rub behavior for 10 dense, sprayed materials and eight current compressor clearance materials was conducted. A literature survey of a wide variety of metallurgical and thermophysical properties was conducted and correlated to rub behavior. Based on the results, the most promising dense rub material was Cu-9A1. Additional studies on the effects of porosity, incursion rate, blade solidity, and ambient temperature were carried out on aluminum bronze (Cu-9Al-1Fe) with and without a 515B Feltmetal underlayer. A further development effort was conducted to assess the property requirements of a porous, aluminum bronze, seal material. Strength, thermal cycle capabilities, erosion and oxidation resistance, machinability, and abradability at several porosity levels were examined.

  19. Evaluation of effervescent atomizer internal design on the spray unsteadiness using a phase/Doppler particle analyzer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Meng; Duan, YuFeng; Zhang, TieNan

    2010-09-15

    The purpose of this research was to investigate the dependence of effervescent spray unsteadiness on operational conditions and atomizer internal design by the ideal spray theory of Edwards and Marx. The convergent-divergent effervescent atomizer spraying water with air as atomizing medium in the ''outside-in'' gas injection was used in this study. Results demonstrated that droplet formation process at various air to liquid ratio (ALR) led to the spray unsteadiness and all droplet size classes exhibited unsteadiness behavior in spray. The spray unsteadiness reduced quickly at ALR of 3% and decreased moderately at ALR of other values as the axial distancemore » increased. When the axial distance was 200 mm, the spray unsteadiness reduced dramatically with the increase in radial distance, but lower spray unsteadiness at the center of spray and higher spray unsteadiness at the edge of spray were shown as the axial distance increased. The spray unsteadiness at the center region of spray increased with the injection pressure. Low spray unsteadiness and good atomization performance can be obtained when the diameter of incline aeration holes increased at ALR of 10%. Although short mixing chamber with large discharge orifice diameter for convergent-divergent effervescent atomizer produced good atomization, the center region of spay showed high spray unsteadiness and maybe formed the droplet clustering. (author)« less

  20. Development and Evaluation of a Combined Cultivator and Band Sprayer with a Row-Centering RTK-GPS Guidance System

    PubMed Central

    Perez-Ruiz, Manuel; Carballido, Jacob; Agüera, Juan; Rodríguez-Lizana, Antonio

    2013-01-01

    Typically, low-pressure sprayers are used to uniformly apply pre- and post-emergent herbicides to control weeds in crop rows. An innovative machine for weed control in inter-row and intra-row areas, with a unique combination of inter-row cultivation tooling and intra-row band spraying for six rows and an electro-hydraulic side-shift frame controlled by a GPS system, was developed and evaluated. Two weed management strategies were tested in the field trials: broadcast spraying (the conventional method) and band spraying with mechanical weed control using RTK-GPS (the experimental method). This approach enabled the comparison between treatments from the perspective of cost savings and efficacy in weed control for a sugar beet crop. During the 2010–2011 season, the herbicide application rate (112 L ha−1) of the experimental method was approximately 50% of the conventional method, and thus a significant reduction in the operating costs of weed management was achieved. A comparison of the 0.2-trimmed means of weed population post-treatment showed that the treatments achieved similar weed control rates at each weed survey date. Sugar beet yields were similar with both methods (p = 0.92). The use of the experimental equipment is cost-effective on ≥20 ha of crops. These initial results show good potential for reducing herbicide application in the Spanish beet industry. PMID:23478600

  1. Development and evaluation of a combined cultivator and band sprayer with a row-centering RTK-GPS guidance system.

    PubMed

    Perez-Ruiz, Manuel; Carballido, Jacob; Agüera, Juan; Rodríguez-Lizana, Antonio

    2013-03-11

    Typically, low-pressure sprayers are used to uniformly apply pre- and post-emergent herbicides to control weeds in crop rows. An innovative machine for weed control in inter-row and intra-row areas, with a unique combination of inter-row cultivation tooling and intra-row band spraying for six rows and an electro-hydraulic side-shift frame controlled by a GPS system, was developed and evaluated. Two weed management strategies were tested in the field trials: broadcast spraying (the conventional method) and band spraying with mechanical weed control using RTK-GPS (the experimental method). This approach enabled the comparison between treatments from the perspective of cost savings and efficacy in weed control for a sugar beet crop. During the 2010-2011 season, the herbicide application rate (112 L ha(-1)) of the experimental method was approximately 50% of the conventional method, and thus a significant reduction in the operating costs of weed management was achieved. A comparison of the 0.2-trimmed means of weed population post-treatment showed that the treatments achieved similar weed control rates at each weed survey date. Sugar beet yields were similar with both methods (p = 0.92). The use of the experimental equipment is cost-effective on ≥20 ha of crops. These initial results show good potential for reducing herbicide application in the Spanish beet industry.

  2. High-Performance Molybdenum Coating by Wire–HVOF Thermal Spray Process

    NASA Astrophysics Data System (ADS)

    Tailor, Satish; Modi, Ankur; Modi, S. C.

    2018-04-01

    Coating deposition on many industrial components with good microstructural, mechanical properties, and better wear resistance is always a challenge for the thermal spray community. A number of thermal spray methods are used to develop such promising coatings for many industrial applications, viz. arc spray, flame spray, plasma, and HVOF. All these processes have their own limitations to achieve porous free, very dense, high-performance wear-resistant coatings. In this work, an attempt has been made to overcome this limitation. Molybdenum coatings were deposited on low-carbon steel substrates using wire-high-velocity oxy-fuel (W-HVOF; WH) thermal spray system (trade name HIJET 9610®). For a comparison, Mo coatings were also fabricated by arc spray, flame spray, plasma spray, and powder-HVOF processes. As-sprayed coatings were analyzed using x-ray diffraction, scanning electron microscopy for phase, and microstructural analysis, respectively. Coating microhardness, surface roughness, and porosity were also measured. Adhesion strength and wear tests were conducted to determine the mechanical and wear properties of the as-sprayed coatings. Results show that the coatings deposited by W-HVOF have better performance in terms of microstructural, mechanical, and wear resistance properties, in comparison with available thermal spray process (flame spray and plasma spray).

  3. Particle size distribution of aerosols sprayed from household hand-pump sprays containing fluorine-based and silicone-based compounds.

    PubMed

    Kawakami, Tsuyoshi; Isama, Kazuo; Ikarashi, Yoshiaki

    2015-01-01

    Japan has published safety guideline on waterproof aerosol sprays. Furthermore, the Aerosol Industry Association of Japan has adopted voluntary regulations on waterproof aerosol sprays. Aerosol particles of diameter less than 10 µm are considered as "fine particles". In order to avoid acute lung injury, this size fraction should account for less than 0.6% of the sprayed aerosol particles. In contrast, the particle size distribution of aerosols released by hand-pump sprays containing fluorine-based or silicone-based compounds have not been investigated in Japan. Thus, the present study investigated the aerosol particle size distribution of 16 household hand-pump sprays. In 4 samples, the ratio of fine particles in aerosols exceeded 0.6%. This study confirmed that several hand-pump sprays available in the Japanese market can spray fine particles. Since the hand-pump sprays use water as a solvent and their ingredients may be more hydrophilic than those of aerosol sprays, the concepts related to the safety of aerosol-sprays do not apply to the hand pump sprays. Therefore, it may be required for the hand-pump spray to develop a suitable method for evaluating the toxicity and to establish the safety guideline.

  4. Investigation of Fuel Oil/Lube Oil Spray Fires On Board Vessels. Volume 3.

    DTIC Science & Technology

    1998-11-01

    U.S. Coast Guard Research and Development Center 1082 Shennecossett Road, Groton, CT 06340-6096 Report No. CG-D-01-99, III Investigation of Fuel ...refinery). Developed the technical and mathematical specifications for BRAVO™2.0, a state-of-the-art Windows program for performing event tree and fault...tree analyses. Also managed the development of and prepared the technical specifications for QRA ROOTS™, a Windows program for storing, searching K-4

  5. Aerothermal modeling program, phase 1

    NASA Technical Reports Server (NTRS)

    Sturgess, G. J.

    1983-01-01

    The physical modeling embodied in the computational fluid dynamics codes is discussed. The objectives were to identify shortcomings in the models and to provide a program plan to improve the quantitative accuracy. The physical models studied were for: turbulent mass and momentum transport, heat release, liquid fuel spray, and gaseous radiation. The approach adopted was to test the models against appropriate benchmark-quality test cases from experiments in the literature for the constituent flows that together make up the combustor real flow.

  6. Development of spray guns for the application of rigid foam insulation

    NASA Technical Reports Server (NTRS)

    Allen, Peter B.

    1993-01-01

    The paper describes the activities initiated to improve the existing spray gun system used for spraying insulating foam on the External Tank of the Space Shuttle, due to the quality variations of the applied foam noted in the past. Consideration is given to the two tasks of the project: (1) investigations of possible improvements, as an interim measure, to the spray gun currently used to apply the large acreage spray-on-foam insulation and the evaluation of other commercial equipment; and (2) the design and fabrication of a new automatic spray gun. The design and operation of the currently used Binks 43 PA spray gun are described together with several new breadboard spray guns designed and fabricated and the testing procedures developed. These new guns include the Modular Automatic Foam spray gun, the Ball Valve spray gun, and the Tapered Plug Valve (TPV) gun. As a result of tests, the TPV spray gun is recommended to replace the currently used automatic spray gun.

  7. Spray-combustion synthesis: Efficient solution route to high-performance oxide transistors

    PubMed Central

    Yu, Xinge; Smith, Jeremy; Zhou, Nanjia; Zeng, Li; Guo, Peijun; Xia, Yu; Alvarez, Ana; Aghion, Stefano; Lin, Hui; Yu, Junsheng; Chang, Robert P. H.; Bedzyk, Michael J.; Ferragut, Rafael; Marks, Tobin J.; Facchetti, Antonio

    2015-01-01

    Metal-oxide (MO) semiconductors have emerged as enabling materials for next generation thin-film electronics owing to their high carrier mobilities, even in the amorphous state, large-area uniformity, low cost, and optical transparency, which are applicable to flat-panel displays, flexible circuitry, and photovoltaic cells. Impressive progress in solution-processed MO electronics has been achieved using methodologies such as sol gel, deep-UV irradiation, preformed nanostructures, and combustion synthesis. Nevertheless, because of incomplete lattice condensation and film densification, high-quality solution-processed MO films having technologically relevant thicknesses achievable in a single step have yet to be shown. Here, we report a low-temperature, thickness-controlled coating process to create high-performance, solution-processed MO electronics: spray-combustion synthesis (SCS). We also report for the first time, to our knowledge, indium-gallium-zinc-oxide (IGZO) transistors having densification, nanoporosity, electron mobility, trap densities, bias stability, and film transport approaching those of sputtered films and compatible with conventional fabrication (FAB) operations. PMID:25733848

  8. Spray-combustion synthesis: efficient solution route to high-performance oxide transistors.

    PubMed

    Yu, Xinge; Smith, Jeremy; Zhou, Nanjia; Zeng, Li; Guo, Peijun; Xia, Yu; Alvarez, Ana; Aghion, Stefano; Lin, Hui; Yu, Junsheng; Chang, Robert P H; Bedzyk, Michael J; Ferragut, Rafael; Marks, Tobin J; Facchetti, Antonio

    2015-03-17

    Metal-oxide (MO) semiconductors have emerged as enabling materials for next generation thin-film electronics owing to their high carrier mobilities, even in the amorphous state, large-area uniformity, low cost, and optical transparency, which are applicable to flat-panel displays, flexible circuitry, and photovoltaic cells. Impressive progress in solution-processed MO electronics has been achieved using methodologies such as sol gel, deep-UV irradiation, preformed nanostructures, and combustion synthesis. Nevertheless, because of incomplete lattice condensation and film densification, high-quality solution-processed MO films having technologically relevant thicknesses achievable in a single step have yet to be shown. Here, we report a low-temperature, thickness-controlled coating process to create high-performance, solution-processed MO electronics: spray-combustion synthesis (SCS). We also report for the first time, to our knowledge, indium-gallium-zinc-oxide (IGZO) transistors having densification, nanoporosity, electron mobility, trap densities, bias stability, and film transport approaching those of sputtered films and compatible with conventional fabrication (FAB) operations.

  9. Spray-coated single walled carbon nanotubes as source and drain electrodes in SnO thin-film transistors

    NASA Astrophysics Data System (ADS)

    Ryu, Jae Hyeon; Baek, Geun-Woo; Kim, Seung Yeob; Kwon, Hyuck-In; Jin, Sung Hun

    2018-07-01

    In this letter, spray-coated single walled carbon nanotubes (SWNTs) as one of alternative electrodes in SnO thin-film transistors are demonstrated for emerging electronic applications. Herein, the device architecture of SnO TFTs with a polymer etch stop layer (SU-8) enables the selective etching of SWNTs in a desired region without the detrimental effects of SnO channel layers. Moreover, SnO TFTs with SWNT electrodes as substitutes successfully demonstrate decent width normalized electrical contact properties (∼1.49 kΩ cm), field effect mobility (∼0.69 cm2 V‑1 s‑1), sub-threshold slope (∼0.4 V dec‑1), and current on–off ratio (I on/I off ∼ 3.5 × 103). Systematic temperature dependency measurements elucidate that SnO channel transports with an activation energy within several tens of meV, together with decent contact resistance as compared to that of conventional Ni electrodes.

  10. Y-junction carbon nanocoils: synthesis by chemical vapor deposition and formation mechanism

    PubMed Central

    Ding, Er-Xiong; Wang, Jing; Geng, Hong-Zhang; Wang, Wen-Yi; Wang, Yan; Zhang, Ze-Chen; Luo, Zhi-Jia; Yang, Hai-Jie; Zou, Cheng-Xiong; Kang, Jianli; Pan, Lujun

    2015-01-01

    Y-junction carbon nanocoils (Y-CNCs) were synthesized by thermal chemical vapor deposition using Ni catalyst prepared by spray-coating method. According to the emerging morphologies of Y-CNCs, several growth models were advanced to elucidate their formation mechanisms. Regarding the Y-CNCs without metal catalyst in the Y-junctions, fusing of contiguous CNCs and a tip-growth mechanism are considered to be responsible for their formation. However, as for the Y-CNCs with catalyst presence in the Y-junctions, the formation can be ascribed to nanoscale soldering/welding and bottom-growth mechanism. It is found that increasing spray-coating time for catalyst preparation generates agglomerated larger nanoparticles strongly adhering to the substrate, resulting in bottom-growth of CNCs and appearance of the metal catalyst in the Y-junctions. In the contrary case, CNCs catalyzed by isolated smaller nanoparticles develop Y-junctions with an absence of metal catalyst by virtue of weaker adhesion of catalyst with the substrate and tip-growth of CNCs. PMID:26063127

  11. An evaluation of the electric arc spray and (HPPS) processes for the manufacturing of high power plasma spraying MCrAIY coatings

    NASA Astrophysics Data System (ADS)

    Sacriste, D.; Goubot, N.; Dhers, J.; Ducos, M.; Vardelle, A.

    2001-06-01

    The high power plasma torch (PlazJet) can be used to spray refractory ceramics with high spray rates and deposition efficiency. It can provide dense and hard coating with high bond strengths. When manufacturing thermal barrier coatings, the PlazJet gun is well adapted to spraying the ceramic top coat but not the MCrAIY materials that are used as bond coat. Arc spraying can compete with plasma spraying for metallic coatings since cored wires can be used to spray alloys and composites. In addition, the high production rate of arc spraying enables a significant decrease in coating cost. This paper discusses the performances of the PlazJet gun, and a twin-wire are spray system, and compares the properties and cost of MCrAIY coatings made with these two processes. For arc spraying, the use of air or nitrogen as atomizing gas is also investigated.

  12. Experimental characterization of gasoline sprays under highly evaporating conditions

    NASA Astrophysics Data System (ADS)

    Khan, Muhammad Mahabat; Sheikh, Nadeem Ahmed; Khalid, Azfar; Lughmani, Waqas Akbar

    2018-05-01

    An experimental investigation of multistream gasoline sprays under highly evaporating conditions is carried out in this paper. Temperature increase of fuel and low engine pressure could lead to flash boiling. The spray shape is normally modified significantly under flash boiling conditions. The spray plumes expansion along with reduction in the axial momentum causes the jets to merge and creates a low-pressure area below the injector's nozzle. These effects initiate the collapse of spray cone and lead to the formation of a single jet plume or a big cluster like structure. The collapsing sprays reduces exposed surface and therefore they last longer and subsequently penetrate more. Spray plume momentum increase, jet plume reduction and spray target widening could delay or prevent the closure condition and limit the penetration (delayed formation of the cluster promotes evaporation). These spray characteristics are investigated experimentally using shadowgraphy, for five and six hole injectors, under various boundary conditions. Six hole injectors produce more collapsing sprays in comparison to five hole injector due to enhanced jet to jet interactions. The spray collapse tendency reduces with increase in injection pressure due high axial momentum of spray plumes. The spray evaporation rates of five hole injector are observed to be higher than six hole injectors. Larger spray cone angles of the six hole injectors promote less penetrating and less collapsing sprays.

  13. Effects of nozzle type and spray angle on spray deposition in ivy pot plants.

    PubMed

    Foqué, Dieter; Nuyttens, David

    2011-02-01

    Fewer plant protection products are now authorised for use in ornamental growings. Frequent spraying with the same product or a suboptimal technique can lead to resistance in pests and diseases. Better application techniques could improve the sustainable use of the plant protection products still available. Spray boom systems--instead of the still predominantly used spray guns--might improve crop protection management in greenhouses considerably. The effect of nozzle type, spray pressure and spray angle on spray deposition and coverage in ivy pot plants was studied, with a focus on crop penetration and spraying the bottom side of the leaves in this dense crop. The experiments showed a significant and important effect of collector position on deposition and coverage in the plant. Although spray deposition and coverage on the bottom side of the leaves are generally low, they could be improved 3.0-4.9-fold using the appropriate application technique. When using a spray boom in a dense crop, the nozzle choice, spray pressure and spray angle should be well considered. The hollow-cone, the air-inclusion flat-fan and the standard flat-fan nozzle with an inclined spray angle performed best because of the effect of swirling droplets, droplets with a high momentum and droplet direction respectively. Copyright © 2010 Society of Chemical Industry.

  14. Benzocaine-induced Methemoglobinemia

    PubMed Central

    Hegedus, Frederick; Herb, Kathleen

    2005-01-01

    A case is reported in which a patient developed methemoglobinemia-induced cyanosis while under general anesthesia during surgery for multiple fascial space infections. The cause of methemoglobinemia was 20% benzocaine spray used for local anesthesia before intubation. Acutely developing methemoglobinemia is infrequently encountered in clinical practice. When confronted with cyanosis in the absence of cardiac or pulmonary disease, one must seriously consider the diagnosis of methe-moglobinemia. The etiology of methemoglobinemia, the causative agents, the diagnosis, and the emergency treatment required are discussed. PMID:16596913

  15. A decision-support tool to predict spray deposition of insecticides in commercial potato fields and its implications for their performance

    USDA-ARS?s Scientific Manuscript database

    In conventional and most IPM programs, application of insecticides continues to be the most important responsive pest control tactic. For both immediate and long-term optimization and sustainability of insecticide applications, it is paramount to study the factors affecting the performance of insect...

  16. 10 CFR 431.408 - Preemption of State regulations for covered equipment other than electric motors and commercial...

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... conservation standard, or water conservation standard (in the case of commercial prerinse spray valves or... other than electric motors and commercial heating, ventilating, air-conditioning and water heating products. 431.408 Section 431.408 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM...

  17. Painter and Decorator: Apprenticeship Course Outline. Apprenticeship and Industry Training. 0409

    ERIC Educational Resources Information Center

    Alberta Advanced Education and Technology, 2009

    2009-01-01

    The graduate of the Painter and Decorator apprenticeship program is a certified journeyperson who will be able to: (1) apply coatings by brush, roller and spray to surfaces of wood, metal, brick, concrete, plaster, stucco and stone for decorative and protective purposes. This occurs in residential, commercial, institutional and industrial…

  18. 10 CFR 431.408 - Preemption of State regulations for covered equipment other than electric motors and commercial...

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... products. 431.408 Section 431.408 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM...-conditioning and water heating products. This section concerns State regulations providing for any energy conservation standard, or water conservation standard (in the case of commercial prerinse spray valves or...

  19. 10 CFR 431.408 - Preemption of State regulations for covered equipment other than electric motors and commercial...

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... products. 431.408 Section 431.408 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM...-conditioning and water heating products. This section concerns State regulations providing for any energy conservation standard, or water conservation standard (in the case of commercial prerinse spray valves or...

  20. NATIONAL INCINERATOR TESTING AND EVALUATION PROGRAM: THE ENVIRONMENTAL CHARACTERIZATION OF REFUSE-DERIVED FUEL (RDF) COMBUSTION TECHNOLOGY - MID-CONNECTICUT FACILITY,

    EPA Science Inventory

    The report gives results of an environmental characterization of refuse-derived, semi-suspension burning technology at a facility in Hartford, CT, that represents state-of-the-art technology, including a spray dryer/fabric filter flue gas cleaning (FGC) system for each unit. The ...

  1. Spray-formed tooling

    NASA Astrophysics Data System (ADS)

    McHugh, K. M.; Key, J. F.

    The United States Council for Automotive Research (USCAR) has formed a partnership with the Idaho National Engineering Laboratory (INEL) to develop a process for the rapid production of low-cost tooling based on spray forming technology developed at the INEL. Phase 1 of the program will involve bench-scale system development, materials characterization, and process optimization. In Phase 2, prototype systems will be designed, constructed, evaluated, and optimized. Process control and other issues that influence commercialization will be addressed during this phase of the project. Technology transfer to USCAR, or a tooling vendor selected by USCAR, will be accomplished during Phase 3. The approach INEL is using to produce tooling, such as plastic injection molds and stamping dies, combines rapid solidification processing and net-shape materials processing into a single step. A bulk liquid metal is pressure-fed into a de Laval spray nozzle transporting a high velocity, high temperature inert gas. The gas jet disintegrates the metal into fine droplets and deposits them onto a tool pattern made from materials such as plastic, wax, clay, ceramics, and metals. The approach is compatible with solid freeform fabrication techniques such as stereolithography, selective laser sintering, and laminated object manufacturing. Heat is extracted rapidly, in-flight, by convection as the spray jet entrains cool inert gas to produce undercooled and semi-solid droplets. At the pattern, the droplets weld together while replicating the shape and surface features of the pattern. Tool formation is rapid; deposition rates in excess of 1 ton/h have been demonstrated for bench-scale nozzles.

  2. Behavior of radioactive iodine and technetium in the spray calcination of high-level waste

    NASA Astrophysics Data System (ADS)

    Knox, C. A.; Farnsworth, R. K.

    1981-08-01

    The Remote Laboratory-Scale Waste Treatment Facility (RLSWTF) was designed and built as a part of the High-Level Waste Immobilization Program (now the High-Level Waste Process Development Program) at the Pacific Northwest Laboratory. In facility, installed in a radiochemical cell, is described in which installed in a radiochemical cell is described in which small volumes of radioactive liquid wastes can be solidified, the process off gas can be analyzed, and the methods for decontaminating this off gas can be tested. During the spray calcination of commercial high-level liquid waste spiked with Tc-99 and I-131 and 31 wt% loss of I-131 past the sintered-metal filters. These filters and venturi scrubber were very efficient in removing particulates and Tc-99 from the the off-gas stream. Liquid scrubbers were not efficient in removing I-131 as 25% of the total lost went to the building off-gas system. Therefore, solid adsorbents are needed to remove iodine. For all future operations where iodine is present, a silver zeolite adsorber is to be used.

  3. An Overview of Pest Species of Bactrocera Fruit Flies (Diptera: Tephritidae) and the Integration of Biopesticides with Other Biological Approaches for Their Management with a Focus on the Pacific Region

    PubMed Central

    Vargas, Roger I.; Piñero, Jaime C.; Leblanc, Luc

    2015-01-01

    Fruit flies (Diptera: Tephritidae) are among the most economically important pest species in the world, attacking a wide range of fruits and fleshy vegetables throughout tropical and sub-tropical areas. These species are such devastating crop pests that major control and eradication programs have been developed in various parts of the world to combat them. The array of control methods includes insecticide sprays to foliage and soil, bait-sprays, male annihilation techniques, releases of sterilized flies and parasitoids, and cultural controls. During the twenty first century there has been a trend to move away from control with organophosphate insecticides (e.g., malathion, diazinon, and naled) and towards reduced risk insecticide treatments. In this article we present an overview of 73 pest species in the genus Bactrocera, examine recent developments of reduced risk technologies for their control and explore Integrated Pest Management (IPM) Programs that integrate multiple components to manage these pests in tropical and sub-tropical areas. PMID:26463186

  4. Notes on the KIVA-2 software and chemically reactive fluid mechanics

    NASA Astrophysics Data System (ADS)

    Holst, M. J.

    1992-09-01

    Working notes regarding the mechanics of chemically reactive fluids with sprays, and their numerical simulation with the KIVA-2 software are presented. KIVA-2 is a large FORTRAN program developed at Los Alamos National Laboratory for internal combustion engine simulation. It is our hope that these notes summarize some of the necessary background material in fluid mechanics and combustion, explain the numerical methods currently used in KIVA-2 and similar combustion codes, and provide an outline of the overall structure of KIVA-2 as a representative combustion program, in order to aid the researcher in the task of implementing KIVA-2 or a similar combustion code on a massively parallel computer. The notes are organized into three parts as follows. In Part 1, a brief introduction to continuum mechanics, to fluid mechanics, and to the mechanics of chemically reactive fluids with sprays is presented. In Part 2, a close look at the governing equations of KIVA-2 is taken, and the methods employed in the numerical solution of these equations is discussed. Some conclusions are drawn and some observations are made in Part 3.

  5. Optimization of Fibrin Glue Spray Systems for Ophthalmic Surgery

    PubMed Central

    Chaurasia, Shyam S.; Champakalakshmi, Ravi; Angunawela, Romesh I.; Tan, Donald T.; Mehta, Jodhbir S.

    2012-01-01

    Purpose To optimize fibrin glue (FG) spray for ophthalmic surgery using two spray applicators, EasySpray and DuploSpray systems, by varying the distance from point of application and the pressure/flow rate, and to compare the adhesive strength of sutured and sutureless (FG sprayed) conjunctival graft surgery in a rabbit model. Methods FG was sprayed on a 0.2 mm-thick sheet of paper using EasySpray by variously combining application distances of 2.5, 5, 7.5, and 10 cm with pressures of 10, 15, and 20 psi. DuploSpray was used at the same distances but with varying flow rates of 1 and 2 L/min. Subsequently, FG was sprayed on porcine corneas and FG thickness was analyzed by histology. In addition, adhesive strength of the conjunctival graft (0.5 × 0.5 cm) attached to the rabbit cornea by sutured and sutureless surgery (FG spray) was compared using a tension meter. Results Histology measurements revealed that the FG thickness decreased with increases in distance and pressure of spray using the EasySpray applicator on paper and porcine corneal sections. The adhesive strength of the sutured conjunctival graft (41 ± 4.85 [kilopascal] KPa) was found to be higher than the graft attached by spraying (10 ± 2.3 KPa) and the sequential addition of FG (6 ± 0.714 KPa). Conclusions The EasySpray applicator formed a uniform spread of FG at a distance-pressure combination of 5 cm and 20 psi. The conjunctival graft attached with sutures had higher adhesive strength compared with grafts glued with a spray applicator. Although the adhesive strength of FG applied through the applicator was similar to the drop-wise sequential technique, the former was more cost effective because more samples could be sprayed compared with the sequential manual technique. Translational Relevance The standardization of the spray system for the application of FG in ophthalmology will provide an economical method for delivering consistent healing results after surgery. PMID:24049702

  6. A Comparison of Fuel Sprays from Several Types of Injection Nozzles

    NASA Technical Reports Server (NTRS)

    Lee, Dana W

    1936-01-01

    This report presents the tests results of a series of tests made of the sprays from 14 fuel injection nozzles of 9 different types, the sprays being injected into air at atmospheric density and at 6 and 14 times atmospheric density. High-speed spark photographs of the sprays from each nozzle at each air density were taken at the rate of 2,000 per second, and from them were obtained the dimensions of the sprays and the rates of spray-tip penetration. The sprays were also injected against plasticine targets placed at different distances from the nozzles, and the impressions made in the plasticine were used as an indication of the distribution of the fuel within the spray. Cross-sectional sketches of the different types of sprays are given showing the relative sizes of the spray cores and envelopes. The characteristics of the sprays are compared and discussed with respect to their application to various types of engines.

  7. An application of digital image processing techniques to the characterization of liquid petroleum gas (LPG) spray

    NASA Astrophysics Data System (ADS)

    Qi, Y. L.; Xu, B. Y.; Cai, S. L.

    2006-12-01

    To control fuel injection, optimize combustion and reduce emissions for LPG (liquefied petroleum gas) engines, it is necessary and important to understand the characteristics of LPG sprays. The present work investigates the geometry of LPG sprays, including spray tip penetration, spray angle, projected spray area and spray volume, by using schlieren photography and digital image processing techniques. Two types of single nozzle injectors were studied, with the same nozzle diameter, but one with and one without a double-hole flow-split head. A code developed to analyse the results directly from the digitized images is shown to be more accurate and efficient than manual measurement and analysis. Test results show that a higher injection pressure produces a longer spray tip penetration, a larger projected spray area and spray volume, but a smaller spray cone angle. The injector with the double-hole split-head nozzle produces better atomization and shorter tip penetration at medium and late injection times, but longer tip penetration in the early stage.

  8. Foliar spray banding characteristics

    Treesearch

    A.R. Womac; C.W. Smith; Joseph E. Mulrooney

    2004-01-01

    Foliar spray banding was explored as a means of reducing peticide use compared to broadcast applications. Barious geometric spray patterns and delivery angles of foliar spray bands were investigated to increase spray deposits in a crop row at a constant spray rate of 94 L/ha. Wind-free laboratory results indicated that a banded application using three 65° hollow-cone...

  9. Aerothermal modeling program, phase 2

    NASA Technical Reports Server (NTRS)

    Mongia, H. C.; Patankar, S. V.; Murthy, S. N. B.; Sullivan, J. P.; Samuelsen, G. S.

    1985-01-01

    The main objectives of the Aerothermal Modeling Program, Phase 2 are: to develop an improved numerical scheme for incorporation in a 3-D combustor flow model; to conduct a benchmark quality experiment to study the interaction of a primary jet with a confined swirling crossflow and to assess current and advanced turbulence and scalar transport models; and to conduct experimental evaluation of the air swirler interaction with fuel injectors, assessments of current two-phase models, and verification the improved spray evaporation/dispersion models.

  10. Light extinction method on high-pressure diesel injection

    NASA Astrophysics Data System (ADS)

    Su, Tzay-Fa; El-Beshbeeshy, Mahmound S.; Corradini, Michael L.; Farrell, Patrick V.

    1995-09-01

    A two dimensional optical diagnostic technique based on light extinction was improved and demonstrated in an investigation of diesel spray characteristics at high injection pressures. Traditional light extinction methods require the spray image to be perpendicular to the light path. In the improved light extinction scheme, a tilted spray image which has an angle with the light path is still capable of being processed. This technique utilizes high speed photography and digital image analysis to obtain qualitative and quantitative information of the spray characteristics. The injection system used was an electronically controlled common rail unit injector system with injection pressures up to 100 MPa. The nozzle of the injector was a mini-sac type with six holes on the nozzle tip. Two different injection angle nozzles, 125 degree(s) and 140 degree(s), producing an in-plane tilted spray and an out of plane tilted spray were investigated. The experiments were conducted on a constant volume spray chamber with the injector mounted tilted at an angle of 62.5 degree(s)$. Only one spray plume was viewed, and other sprays were free to inject to the chamber. The spray chamber was pressurized with argon and air under room temperature to match the combustion chamber density at the start of the injection. The experimental results show that the difference in the spray tip penetration length, spray angle, and overall average Sauter mean diameter is small between the in- plane tilted spray and the out of plane tilted spray. The results also show that in-plane tilted spray has a slightly larger axial cross- section Sauter mean diameter than the out of plane tilted spray.

  11. Hydrogen no-vent fill testing in a 5 cubic foot (142 liter) tank using spray nozzle and spray bar liquid injection

    NASA Technical Reports Server (NTRS)

    Moran, Matthew E.; Nyland, Ted W.

    1992-01-01

    A total of 38 hydrogen no-vent fill tests were performed in this test series using various size spray nozzles and a spray bar with different hole sizes in a 5 cubic foot receiver tank. Fill levels of 90 percent by volume or greater were achieved in 26 of the tests while maintaining a receiver tank pressure below 30 psia. Spray nozzles were mounted at the top of the tank, whereas, the spray bar was centered in the tank axially. The spray nozzle no-vent fills demonstrated tank pressure and temperature responses comparable to previous test series. Receiver tank pressure responses for the spray bar configuration were similar to the spray nozzle tests with the pressure initially rising rapidly, then leveling off as vapor condenses onto the discharging liquid streams, and finally ramping up near the end of the test due to ullage compression. Both liquid injection techniques tested were capable of filling the receiver tank to 90 percent under variable test conditions. Comparisons between the spray nozzle and spray bar configurations for well matched test conditions indicate the spray nozzle injection technique is more effective in minimizing the receiving tank pressure throughout a no-vent fill compared to the spray bar under normal gravity conditions.

  12. Effectiveness of Spray-Based Decontamination Methods for ...

    EPA Pesticide Factsheets

    Report The objective of this project was to assess the effectiveness of spray-based common decontamination methods for inactivating Bacillus (B.) atrophaeus (surrogate for B. anthracis) spores and bacteriophage MS2 (surrogate for foot and mouth disease virus [FMDV]) on selected test surfaces (with or without a model agricultural soil load). Relocation of viable viruses or spores from the contaminated coupon surfaces into aerosol or liquid fractions during the decontamination methods was investigated. This project was conducted to support jointly held missions of the U.S. Department of Homeland Security (DHS) and the U.S. Environmental Protection Agency (EPA). Within the EPA, the project supports the mission of EPA’s Homeland Security Research Program (HSRP) by providing relevant information pertinent to the decontamination of contaminated areas resulting from a biological incident.

  13. Application of external axis in thermal spraying

    NASA Astrophysics Data System (ADS)

    Gao, Guoyou; Wang, Wei; Chen, Tao; Hui, Chun

    2018-05-01

    Industrial robots are widely used nowadays in the process of thermal spraying, human work can be largely replaced due to the high-efficient, security, precision and repeatability of industrial robot. As offering the convenience to industrial product, Robots have some natural deficiencies because of its mechanical linkages of six-axis. When robot performs a series of stage of production, it could be hard to move to the next one because one of his axis reaches a maximum value. For this reason, external axis is added to robot system to extend the reachable space of robot axis. This paper concerns to the application of external axis and the different methods of programming the robot with work-holding external axis in the virtual environment. Experiments demonstrate the coating layer on the regular workpiece is uniform.

  14. Spray pattern analysis in TWAS using photogrammetry and digital image correlation

    NASA Astrophysics Data System (ADS)

    Tillmann, W.; Rademacher, H. G.; Hagen, L.; Abdulgader, M.; El Barad’ei, M.

    2018-06-01

    In terms of arc spraying processes, the spray plume characteristic is mainly affected by the flow characteristic of the atomization gas at the nozzle inlet and intersection point of the wire tips, which in turn affect the particle distribution at the moment of impact when molten spray particles splash onto the substrate. With respect to the route of manufacturing of near net-shaped coatings on complex geometries, the acquisition of the spray patterns is pressingly necessary to determine the produced coating thickness. Within the scope of this study, computer fluid dynamics (CFD) simulations were carried out to determine the distribution of spray particles for different spray parameter settings. The results were evaluated by three-dimensional spray spot analyses using an optical measurement based on photogrammetry and digital image correlation. The optical measurement represents a promising and much faster candidate to measure spray patterns compared to the tactile measurement system but with an equal accuracy. For given nozzle configurations and spray parameter settings, numerous spray patterns were examined to their shape factors, demonstrating the potential of an online analysis, which encompasses a “fast sample loop” and a data processing system to generate a three-dimensional surface of the spray spot profile.

  15. Influence of Cold-Sprayed, Warm-Sprayed, and Plasma-Sprayed Layers Deposition on Fatigue Properties of Steel Specimens

    NASA Astrophysics Data System (ADS)

    Cizek, J.; Matejkova, M.; Dlouhy, I.; Siska, F.; Kay, C. M.; Karthikeyan, J.; Kuroda, S.; Kovarik, O.; Siegl, J.; Loke, K.; Khor, Khiam Aik

    2015-06-01

    Titanium powder was deposited onto steel specimens using four thermal spray technologies: plasma spray, low-pressure cold spray, portable cold spray, and warm spray. The specimens were then subjected to strain-controlled cyclic bending test in a dedicated in-house built device. The crack propagation was monitored by observing the changes in the resonance frequency of the samples. For each series, the number of cycles corresponding to a pre-defined specimen cross-section damage was used as a performance indicator. It was found that the grit-blasting procedure did not alter the fatigue properties of the steel specimens (1% increase as compared to as-received set), while the deposition of coatings via all four thermal spray technologies significantly increased the measured fatigue lives. The three high-velocity technologies led to an increase of relative lives to 234% (low-pressure cold spray), 210% (portable cold spray), and 355% (warm spray) and the deposition using plasma spray led to an increase of relative lives to 303%. The observed increase of high-velocity technologies (cold and warm spray) could be attributed to a combination of homogeneous fatigue-resistant coatings and induction of peening stresses into the substrates via the impingement of the high-kinetic energy particles. Given the intrinsic character of the plasma jet (low-velocity impact of semi/molten particles) and the mostly ceramic character of the coating (oxides, nitrides), a hypothesis based on non-linear coatings behavior is provided in the paper.

  16. Thermal barrier coating life prediction model

    NASA Technical Reports Server (NTRS)

    Hillery, R. V.; Pilsner, B. H.; Cook, T. S.; Kim, K. S.

    1986-01-01

    This is the second annual report of the first 3-year phase of a 2-phase, 5-year program. The objectives of the first phase are to determine the predominant modes of degradation of a plasma sprayed thermal barrier coating system and to develop and verify life prediction models accounting for these degradation modes. The primary TBC system consists of an air plasma sprayed ZrO-Y2O3 top coat, a low pressure plasma sprayed NiCrAlY bond coat, and a Rene' 80 substrate. Task I was to evaluate TBC failure mechanisms. Both bond coat oxidation and bond coat creep have been identified as contributors to TBC failure. Key property determinations have also been made for the bond coat and the top coat, including tensile strength, Poisson's ratio, dynamic modulus, and coefficient of thermal expansion. Task II is to develop TBC life prediction models for the predominant failure modes. These models will be developed based on the results of thermmechanical experiments and finite element analysis. The thermomechanical experiments have been defined and testing initiated. Finite element models have also been developed to handle TBCs and are being utilized to evaluate different TBC failure regimes.

  17. Preparation of mesoporous alumina particles by spray pyrolysis and application to double bond migration of 2-butene.

    PubMed

    Song, Ki Chang; Kim, Joo Hyun; Kim, Jin Han; Jung, Kyeong Youl; Park, Young-Kwon; Jeon, Jong-Ki

    2011-07-01

    The objective of the present study is to investigate the catalytic performance of mesoporous alumina that were prepared via spray pyrolysis for double bond migration from 2-butene to 1-butene. The mesoporous alumina particles were prepared via spray pyrolysis by changing the types of organic surfactants and Al precursors. The texture and acidic properties of mesoporous alumina were analyzed through N2 adsorption, SEM, ammonia-temperature programmed desorption, and FT-IR of adsorbed pyridine. The morphologies and texture properties of the mesoporous alumina were found to have been strongly influenced by the combination of the Al precursor and the structure-directing agents. The mesoporous alumina samples had two kinds of acidic sites: a Lewis acid site and a H-bonded weak acid site. 1-Butene was produced selectively through double bond migration of 2-butene over all of the mesoporous alumina catalysts. The catalyst prepared by using a chloride compound as an aluminium precursor and CTAC as a structure-directing agent showed the highest activity in the double bond migration of 2-butene, which was attributed to its large surface area and an overall high amount of acid sites.

  18. Layered growth with bottom-spray granulation for spray deposition of drug.

    PubMed

    Er, Dawn Z L; Liew, Celine V; Heng, Paul W S

    2009-07-30

    The gap in scientific knowledge on bottom-spray fluidized bed granulation has emphasized the need for more studies in this area. This paper comparatively studied the applicability of a modified bottom-spray process and the conventional top-spray process for the spray deposition of a micronized drug during granulation. The differences in circulation pattern, mode of growth and resultant granule properties between the two processes were highlighted. The more ordered and consistent circulation pattern of particles in a bottom-spray fluidized bed was observed to give rise to layered granule growth. This resulted in better drug content uniformity among the granule batches and within a granule batch. The processes' sensitivities to wetting and feed material characteristics were also compared and found to differ markedly. Less robustness to differing process conditions was observed for the top-spray process. The resultant bottom-spray granules formed were observed to be less porous, more spherical and had good flow properties. The bottom-spray technique can thus be potentially applied for the spray deposition of drug during granulation and was observed to be a good alternative to the conventional technique for preparing granules.

  19. Growth of ultra-thin TiO 2 films by spray pyrolysis on different substrates

    NASA Astrophysics Data System (ADS)

    Oja Acik, I.; Junolainen, A.; Mikli, V.; Danilson, M.; Krunks, M.

    2009-12-01

    In the present study TiO 2 films were deposited by spray pyrolysis method onto ITO covered glass and Si (1 0 0) substrates. The spray solution containing titanium(IV) isopropoxide, acetylacetone and ethanol was sprayed at a substrate temperature of 450 °C employing 1-125 spray pulses (1 s spray and 30 s pause). According to AFM, continuous coverage of ITO and Si substrates with TiO 2 layer is formed by 5-10 and below 5 spray pulses, respectively. XPS studies revealed that TiO 2 film growth on Si substrate using up to 4 spray pulses follows 2D or layer-by-layer-growth. Above 4 spray pulses, 3D or island growth becomes dominant irrespective of the substrate. Only 50 spray pulses result in TiO 2 layer with the thickness more than XPS measurement escape depth as any signal from the substrate could not be detected. TiO 2 grain size remains 30 nm on ITO and increases from 10-20 nm to 50-100 nm on Si substrate with the number of spray pulses from 1 to 125.

  20. A critical review on the spray drying of fruit extract: effect of additives on physicochemical properties.

    PubMed

    Krishnaiah, Duduku; Nithyanandam, Rajesh; Sarbatly, Rosalam

    2014-01-01

    Spray drying accomplishes drying while particles are suspended in the air and is one method in the family of suspended particle processing systems, along with fluid-bed drying, flash drying, spray granulation, spray agglomeration, spray reaction, spray cooling, and spray absorption. This drying process is unique because it involves both particle formation and drying. The present paper reviews spray drying of fruit extracts, such as acai, acerola pomace, gac, mango, orange, cactus pear, opuntia stricta fruit, watermelon, and durian, and the effects of additives on physicochemical properties such as antioxidant activity, total carotenoid content, lycopene and β-carotene content, hygroscopy, moisture content, volatile retention, stickiness, color, solubility, glass transition temperature, bulk density, rehydration, caking, appearance under electron microscopy, and X-ray powder diffraction. The literature clearly demonstrates that the effect of additives and encapsulation play a vital role in determining the physicochemical properties of fruit extract powder. The technical difficulties in spray drying of fruit extracts can be overcome by modifying the spray dryer design. It also reveals that spray drying is a novel technology for converting fruit extract into powder form.

  1. Mixing of an Airblast-atomized Fuel Spray Injected into a Crossflow of Air

    NASA Technical Reports Server (NTRS)

    Leong, May Y.; McDonell, Vincent G.; Samuelsen, G. Scott

    2000-01-01

    The injection of a spray of fuel droplets into a crossflow of air provides a means of rapidly mixing liquid fuel and air for combustion applications. Injecting the liquid as a spray reduces the mixing length needed to accommodate liquid breakup, while the transverse injection of the spray into the air stream takes advantage of the dynamic mixing induced by the jet-crossflow interaction. The structure of the spray, formed from a model plain-jet airblast atomizer, is investigated in order to determine and understand the factors leading to its dispersion. To attain this goal, the problem is divided into the following tasks which involve: (1) developing planar imaging techniques that visualize fuel and air distributions in the spray, (2) characterizing the airblast spray without a crossflow, and (3) characterizing the airblast spray upon injection into a crossflow. Geometric and operating conditions are varied in order to affect the atomization, penetration, and dispersion of the spray into the crossflow. The airblast spray is first characterized, using imaging techniques, as it issues into a quiescent environment. The spray breakup modes are classified in a liquid Reynolds number versus airblast Weber number regime chart. This work focuses on sprays formed by the "prompt" atomization mode, which induces a well-atomized and well-dispersed spray, and which also produces a two-lobed liquid distribution corresponding to the atomizing air passageways in the injector. The characterization of the spray jet injected into the crossflow reveals the different processes that control its dispersion. Correlations that describe the inner and outer boundaries of the spray jet are developed, using the definition of a two-phase momentum-flux ratio. Cross-sections of the liquid spray depict elliptically-shaped distributions, with the exception of the finely-atomized sprays which show kidney-shaped distributions reminiscent of those obtained in gaseous jet in crossflow systems. A droplet trajectory analysis overpredicts the liquid mass penetration, and indicates a need for a more rigorous model to account for the three-dimensional mixing field induced by the jet-crossflow interaction. Nonetheless, the general procedures and criteria that are outlined can be used to efficiently assess and compare the quality of sprays formed under different conditions.

  2. A fluorescent imaging technique for quantifying spray deposits on plant leaves

    USDA-ARS?s Scientific Manuscript database

    Because of the unique characteristics of electrostatically-charged sprays, use of traditional methods to quantify deposition from these sprays has been challenging. A new fluorescent imaging technique was developed to quantify spray deposits from electrostatically-charged sprays on natural plant lea...

  3. A user-friendly model for spray drying to aid pharmaceutical product development.

    PubMed

    Grasmeijer, Niels; de Waard, Hans; Hinrichs, Wouter L J; Frijlink, Henderik W

    2013-01-01

    The aim of this study was to develop a user-friendly model for spray drying that can aid in the development of a pharmaceutical product, by shifting from a trial-and-error towards a quality-by-design approach. To achieve this, a spray dryer model was developed in commercial and open source spreadsheet software. The output of the model was first fitted to the experimental output of a Büchi B-290 spray dryer and subsequently validated. The predicted outlet temperatures of the spray dryer model matched the experimental values very well over the entire range of spray dryer settings that were tested. Finally, the model was applied to produce glassy sugars by spray drying, an often used excipient in formulations of biopharmaceuticals. For the production of glassy sugars, the model was extended to predict the relative humidity at the outlet, which is not measured in the spray dryer by default. This extended model was then successfully used to predict whether specific settings were suitable for producing glassy trehalose and inulin by spray drying. In conclusion, a spray dryer model was developed that is able to predict the output parameters of the spray drying process. The model can aid the development of spray dried pharmaceutical products by shifting from a trial-and-error towards a quality-by-design approach.

  4. A spray flamelet/progress variable approach combined with a transported joint PDF model for turbulent spray flames

    NASA Astrophysics Data System (ADS)

    Hu, Yong; Olguin, Hernan; Gutheil, Eva

    2017-05-01

    A spray flamelet/progress variable approach is developed for use in spray combustion with partly pre-vaporised liquid fuel, where a laminar spray flamelet library accounts for evaporation within the laminar flame structures. For this purpose, the standard spray flamelet formulation for pure evaporating liquid fuel and oxidiser is extended by a chemical reaction progress variable in both the turbulent spray flame model and the laminar spray flame structures, in order to account for the effect of pre-vaporised liquid fuel for instance through use of a pilot flame. This new approach is combined with a transported joint probability density function (PDF) method for the simulation of a turbulent piloted ethanol/air spray flame, and the extension requires the formulation of a joint three-variate PDF depending on the gas phase mixture fraction, the chemical reaction progress variable, and gas enthalpy. The molecular mixing is modelled with the extended interaction-by-exchange-with-the-mean (IEM) model, where source terms account for spray evaporation and heat exchange due to evaporation as well as the chemical reaction rate for the chemical reaction progress variable. This is the first formulation using a spray flamelet model considering both evaporation and partly pre-vaporised liquid fuel within the laminar spray flamelets. Results with this new formulation show good agreement with the experimental data provided by A.R. Masri, Sydney, Australia. The analysis of the Lagrangian statistics of the gas temperature and the OH mass fraction indicates that partially premixed combustion prevails near the nozzle exit of the spray, whereas further downstream, the non-premixed flame is promoted towards the inner rich-side of the spray jet since the pilot flame heats up the premixed inner spray zone. In summary, the simulation with the new formulation considering the reaction progress variable shows good performance, greatly improving the standard formulation, and it provides new insight into the local structure of this complex spray flame.

  5. Detailed assessment of diesel spray atomization models using visible and X-ray extinction measurements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Magnotti, G. M.; Genzale, C. L.

    The physical mechanisms characterizing the breakup of a diesel spray into droplets are still unknown. This gap in knowledge has largely been due to the challenges of directly imaging this process or quantitatively measuring the outcomes of spray breakup, such as droplet size. Recent x-ray measurements by Argonne National Laboratory, utilized in this work, provide needed information about the spatial evolution of droplet sizes in selected regions of the spray under a range of injection pressures (50–150 MPa) and ambient densities (7.6–22.8 kg/m3) relevant for diesel operating conditions. Ultra-small angle x-ray scattering (USAXS) measurements performed at the Advanced Photon Sourcemore » are presented, which quantify Sauter mean diameters (SMD) within optically thick regions of the spray that are inaccessible by conventional droplet sizing measurement techniques, namely in the near-nozzle region, along the spray centerline, and within the core of the spray. To quantify droplet sizes along the periphery of the spray, a complementary technique is proposed and introduced, which leverages the ratio of path-integrated x-ray and visible laser extinction (SAMR) measurements to quantify SMD. The SAMR and USAXS measurements are then utilized to evaluate current spray models used for engine computational fluid dynamic (CFD) simulations. We explore the ability of a carefully calibrated spray model, premised on aerodynamic wave growth theory, to capture the experimentally observed trends of SMD throughout the spray. The spray structure is best predicted with an aerodynamic primary and secondary breakup process that is represented with a slower time constant and larger formed droplet size than conventionally recommended for diesel spray models. Additionally, spray model predictions suggest that droplet collisions may not influence the resultant droplet size distribution along the spray centerline in downstream regions of the spray.« less

  6. Wind tunnel and field evaluation of drift from aerial spray applications with multiple spray formulations

    USDA-ARS?s Scientific Manuscript database

    The impact of different spray tank modifiers into an active ingredient spray mixture on spray atomization and in-field behavior under aerial application conditions were examined. Wind tunnel tests demonstrated that active ingredient solutions potentially results in significantly different atomizati...

  7. Spray drift reduction evaluations of spray nozzles using a standardized testing protocol

    USDA-ARS?s Scientific Manuscript database

    The development and testing of drift reduction technologies has come to the forefront of application research in the past few years in the United States. Drift reduction technologies (DRTs) can be spray nozzles, sprayer modifications, spray delivery assistance, spray property modifiers (adjuvants),...

  8. Use of Proper Orthogonal Decomposition Towards Time-resolved Image Analysis of Sprays

    DTIC Science & Technology

    2011-03-15

    High-speed movies of optically dense sprays exiting a Gas-Centered Swirl Coaxial (GCSC) injector are subjected to image analysis to determine spray...sequence prior to image analysis . Results of spray morphology including spray boundary, widths, angles and boundary oscillation frequencies, are

  9. COST EFFECTIVE VOC EMISSION CONTROL STARTEGIES FOR MILITARY, AEROSPACE,AND INDUSTRIAL PAINT SPRAY BOOTH OPERATIONS: COMBINING IMPROVED VENTILATION SYSTEMS WITH INNOVATIVE, LOW COST EMISSION CONTROL TECHNOLOGIES

    EPA Science Inventory

    The paper describes a full-scale demonstration program in which several paint booths were modified for recirculation ventilation; the booth exhaust streams are vented to an innovative volatile organic compound (VOC) emission control system having extremely low operating costs. ...

  10. Land Application of Wastes: An Educational Program. Waste Application Systems - Module 12, Objectives, and Script.

    ERIC Educational Resources Information Center

    Clarkson, W. W.; And Others

    Land application systems are discussed with reference to the options available for applying wastewater and sludge to the site. Spray systems, surface flow methods, and sludge application schemes are all included with discussions of the advantages and disadvantages of each option within these categories. A distinction is made between the choice of…

  11. Predicting Aircraft Spray Patterns on Crops

    NASA Technical Reports Server (NTRS)

    Teske, M. E.; Bilanin, A. J.

    1986-01-01

    Agricultural Dispersion Prediction (AGDISP) system developed to predict deposition of agricultural material released from rotary- and fixed-wing aircraft. AGDISP computes ensemble average mean motion resulting from turbulent fluid fluctuations. Used to examine ways of making dispersal process more efficient by insuring uniformity, reducing waste, and saving money. Programs in AGDISP system written in FORTRAN IV for interactive execution.

  12. Characterization of ZrO2-Y2O3 thermal spray powder systems

    NASA Technical Reports Server (NTRS)

    Mantkowski, Thomas E.; Rigney, David V.; Froning, Marc J.; Jayaraman, N.

    1985-01-01

    The overall objective is to establish the interrelation between the raw material in the coating process and the performance of the coating deposit. It is anticipated that these interrelations will help establish more precise specifications for the procurement of the raw materials. Some of the preliminary results of the program are presented.

  13. EVALUATION OF FGD DRY INJECTION SORBENTS AND ADDITIVES - VOLUME 2 - PILOT PLANT EVALUATION OF HIGH REACTIVITY SORBENTS

    EPA Science Inventory

    The report describes a mini-pilot test program to investigate potential new sorbents and processes for dry SO2 removal. Initial tests showed that the 85 cu m/h pilot plant could be used successfully to evaluate both spray dryer and dry injection processes using traditional calciu...

  14. Aerothermal modeling program, phase 1

    NASA Technical Reports Server (NTRS)

    Srinivasan, R.; Reynolds, R.; Ball, I.; Berry, R.; Johnson, K.; Mongia, H.

    1983-01-01

    Aerothermal submodels used in analytical combustor models are analyzed. The models described include turbulence and scalar transport, gaseous full combustion, spray evaporation/combustion, soot formation and oxidation, and radiation. The computational scheme is discussed in relation to boundary conditions and convergence criteria. Also presented is the data base for benchmark quality test cases and an analysis of simple flows.

  15. Evaluation of barrier treatments on native vegetation in a southern California desert habitat.

    PubMed

    Britch, Seth C; Linthicum, Kenneth J; Wynn, Wayne W; Walker, Todd W; Farooq, Muhammad; Smith, Vincent L; Robinson, Cathy A; Lothrop, Branka B; Snelling, Melissa; Gutierrez, Arturo; Lothrop, Hugh D

    2009-06-01

    Treating perimeters with residual insecticides for protection from mosquito vectors has shown promise. These barrier treatments are typically evaluated in temperate or tropical areas using abundant vegetation as a substrate. However, there is an emerging interest to develop this technology to protect deployed US troops in extreme desert environments with sparse vegetation. We used a remote desert area in the Coachella Valley, California, to 1) evaluate bifenthrin barrier treatments on native xeric vegetation and 2) compare treatments applied with electrostatic and conventional spray technologies. Through a combination of laboratory bioassays on treated and control vegetation sampled at specific intervals over 63 days, synchronized with field surveillance of mosquitoes, we measured the temporal pattern of bioactivity of bifenthrin barriers under natural hot, dry, and dusty desert conditions. Regardless of spray technology, mosquito catch in treated plots was about 80% lower than the catch in control plots 1 day after treatment. This reduction in mosquito numbers in treated plots declined each week after treatment but remained at about 40% lower than control plots after 28 days. Field data were corroborated by results from bioassays that showed significantly higher mosquito mortality on treated vegetation over controls out to 28 days postspray. We concluded that barrier treatments in desert environments, when implemented as part of a suite of integrated control measures, may offer a significant level of protection from mosquitoes for deployed troops. Given the comparable performance of the tested spray technologies, we discuss considerations for choosing a barrier treatment sprayer for military scenarios.

  16. A pragmatic approach for engineering porous mannitol and mechanistic evaluation of particle performance.

    PubMed

    Al-Khattawi, Ali; Koner, Jasdip; Rue, Peter; Kirby, Dan; Perrie, Yvonne; Rajabi-Siahboomi, Ali; Mohammed, Afzal R

    2015-08-01

    The importance of mannitol has increased recently as an emerging diluent for orodispersible dosage forms. The study aims to prepare spray dried mannitol retaining high porosity and mechanical strength for the development of orally disintegrating tablets (ODTs). Aqueous feed of d-mannitol (10% w/v) comprising ammonium bicarbonate, NH4HCO3 (5% w/v) as pore former was spray dried at inlet temperature of 110-170°C. Compacts were prepared at 151MPa and characterized for porosity, hardness and disintegration time. Particle morphology and drying mechanisms were studied using thermal (HSM, DSC and TGA) and polymorphic (XRD) methods. Tablet porosity increased from 0.20±0.002 for pure mannitol to 0.53±0.03 using fabricated porous mannitol. Disintegration time dropped by 50-77% from 135±5.29s for pure mannitol to 75.33±2.52-31.67±1.53s for mannitol 110-170°C. Hardness increased by 150% at 110°C (258.67±28.89N) and 30% at 150°C (152.70±10.58N) compared to pure mannitol tablets (104.17±1.70N). Increasing inlet temperature resulted in reducing tablet hardness due to generation of 'micro-sponge'-like particles exhibiting significant elastic recovery. Impact of mannitol polymorphism on plasticity/elasticity cannot be ruled out as a mixture of α and β polymorphs formed upon spray drying. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Ultrasonically spray coated silver layers from designed precursor inks for flexible electronics.

    PubMed

    Marchal, W; Vandevenne, G; D'Haen, J; Calmont de Andrade Almeida, A; Durand Sola, M A; van den Ham, E J; Drijkoningen, J; Elen, K; Deferme, W; Van Bael, M K; Hardy, A

    2017-05-26

    Integration of electronic circuit components onto flexible materials such as plastic foils, paper and textiles is a key challenge for the development of future smart applications. Therefore, conductive metal features need to be deposited on temperature sensitive substrates in a fast and straightforward way. The feasibility of these emerging (nano-) electronic technologies depends on the availability of well-designed deposition techniques and on novel functional metal inks. As ultrasonic spray coating (USSC) is one of the most promising techniques to meet the above requirements, innovative metal organic decomposition (MOD) inks are designed to deposit silver features on plastic foils. Various amine ligands were screened and their influence on the ink stability and the characteristics of the resulting metal depositions were evaluated to determine the optimal formulation. Eventually, silver layers with excellent performance in terms of conductivity (15% bulk silver conductivity), stability, morphology and adhesion could be obtained, while operating in a very low temperature window of 70 °C-120 °C. Moreover, the optimal deposition conditions were determined via an in-depth analysis of the ultrasonically sprayed silver layers. Applying these tailored MOD inks, the USSC technique enabled smooth, semi-transparent silver layers with a tunable thickness on large areas without time-consuming additional sintering steps after deposition. Therefore, this novel combination of nanoparticle-free Ag-inks and the USSC process holds promise for high throughput deposition of highly conductive silver features on heat sensitive substrates and even 3D objects.

  18. Ultrasonically spray coated silver layers from designed precursor inks for flexible electronics

    NASA Astrophysics Data System (ADS)

    Marchal, W.; Vandevenne, G.; D'Haen, J.; Almeida, A. Calmont de Andrade; Durand Sola, M. A., Jr.; van den Ham, E. J.; Drijkoningen, J.; Elen, K.; Deferme, W.; Van Bael, M. K.; Hardy, A.

    2017-05-01

    Integration of electronic circuit components onto flexible materials such as plastic foils, paper and textiles is a key challenge for the development of future smart applications. Therefore, conductive metal features need to be deposited on temperature sensitive substrates in a fast and straightforward way. The feasibility of these emerging (nano-) electronic technologies depends on the availability of well-designed deposition techniques and on novel functional metal inks. As ultrasonic spray coating (USSC) is one of the most promising techniques to meet the above requirements, innovative metal organic decomposition (MOD) inks are designed to deposit silver features on plastic foils. Various amine ligands were screened and their influence on the ink stability and the characteristics of the resulting metal depositions were evaluated to determine the optimal formulation. Eventually, silver layers with excellent performance in terms of conductivity (15% bulk silver conductivity), stability, morphology and adhesion could be obtained, while operating in a very low temperature window of 70 °C-120 °C. Moreover, the optimal deposition conditions were determined via an in-depth analysis of the ultrasonically sprayed silver layers. Applying these tailored MOD inks, the USSC technique enabled smooth, semi-transparent silver layers with a tunable thickness on large areas without time-consuming additional sintering steps after deposition. Therefore, this novel combination of nanoparticle-free Ag-inks and the USSC process holds promise for high throughput deposition of highly conductive silver features on heat sensitive substrates and even 3D objects.

  19. Pre-flight risk assessment in Emergency Medical Service (EMS) helicopters

    NASA Technical Reports Server (NTRS)

    Shively, R. J.

    1992-01-01

    The Emergency Medical Service (EMS) industry has been the subject of several television and newspaper articles (Harvey and Jensen, 1987) which emphasized the negative aspects, (e.g., fatalities and high accident rates), rather than the life saving services performed. Until recently, the accident rate of the EMS industry has been five times as high as that of other civil helicopters. This high accident rate has been coupled with the dramatic rise in the number of programs. The industry has built from a single service at its inception in 1972, to over 180 in 1987 (Spray, 1987), to the point that 93 percent of the contiguous U.S. is now covered by some type of EMS service. These factors prompted the National Transportation Safety Board (NTSB) to study the accidents that occurred between May 11, 1978 and December 3, 1986 (NTSB, 1988). The NTSB report concluded that 'Sound pilot judgment is central to safe flight operations.' They further stated that '... factors unique to EMS helicopter operations--such as the influence of the mission itself, program competition, and EMS program management perspectives--can drastically influence pilot judgment during the EMS mission.' One of the most difficult decisions that a pilot must make is whether to accept or decline a mission. A pre-flight risk assessment system (SAFE) was developed at NASA-Ames Research Center for civil EMS operations to aid pilots in making this decision objectively. The ability of the SAFE system to predict mission risk profiles was tested at an EMS facility. The results of this field study demonstrated that the usefulness of SAFE was highly dependent on the type of mission flown. SAFE is now being modified so that it can 'learn' with each mission flown. For example, after flying a mission to a particular site, an EMS pilot would input information about this mission into the system, such as new buildings, wires, or approach procedures. Then, the next time a pilot flew a similar mission or one to the same area, this additional information would be taken into account in computing a risk assessment.

  20. 40 CFR 63.11177 - What records must I keep?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ....11173(e)(3)(i). (c) Documentation from the spray gun manufacturer that each spray gun with a cup... operation, you must keep the records specified in paragraphs (e) through (g) of this section, as applicable... spray gun, electrostatic application, airless spray gun, or air assisted airless spray gun, has been...

  1. Modifications Of A Commercial Spray Gun

    NASA Technical Reports Server (NTRS)

    Allen, Peter B.

    1993-01-01

    Commercial spray gun modified to increase spray rate and make sprayed coats more nearly uniform. Consists of gun head and pneumatic actuator. Actuator opens valves for two chemical components, called "A" and "B," that react to produce foam. Components flow through orifices, into mixing chamber in head. Mixture then flows through control orifice to spray tip. New spray tip tapered to reduce area available for accumulation of foam and makes tip easier to clean.

  2. Multiple-Nozzle Spray Head Applies Foam Insulation

    NASA Technical Reports Server (NTRS)

    Walls, Joe T.

    1993-01-01

    Spray head equipped with four-nozzle turret mixes two reactive components of polyurethane and polyisocyanurate foam insulating material and sprays reacting mixture onto surface to be insulated. If nozzle in use becomes clogged, fresh one automatically rotated into position, with minimal interruption of spraying process. Incorporates features recirculating and controlling pressures of reactive components to maintain quality of foam by ensuring proper blend at outset. Also used to spray protective coats on or in ships, aircraft, and pipelines. Sprays such reactive adhesives as epoxy/polyurethane mixtures. Components of spray contain solid-particle fillers for strength, fire retardance, toughness, resistance to abrasion, or radar absorption.

  3. Characterization of sprays

    NASA Technical Reports Server (NTRS)

    Chigier, N.; Mao, C.-P.

    1984-01-01

    It is pointed out that most practical power generation and propulsion systems involve the burning of different types of fuel sprays, taking into account aircraft propulsion, industrial furnaces, boilers, gas turbines, and diesel engines. There has been a lack of data which can serve as a basis for spray model development and validation. A major aim of the present investigation is to fill this gap. Experimental apparatus and techniques for studying the characteristics of fuel sprays are discussed, taking into account two-dimensional still photography, cinematography, holography, a laser diffraction particle sizer, and a laser anemometer. The considered instruments were used in a number of experiments, taking into account three different types of fuel spray. Attention is given to liquid fuel sprays, high pressure pulsed diesel sprays, and coal-water slurry sprays.

  4. Analysis of high injection pressure and ambient temperature on biodiesel spray characteristics using computational fluid dynamics

    NASA Astrophysics Data System (ADS)

    Hashim, Akasha; Khalid, Amir; Jaat, Norrizam; Sapit, Azwan; Razali, Azahari; Nizam, Akmal

    2017-09-01

    Efficiency of combustion engines are highly affected by the formation of air-fuel mixture prior to ignition and combustion process. This research investigate the mixture formation and spray characteristics of biodiesel blends under variant in high ambient and injection conditions using Computational Fluid Dynamics (CFD). The spray characteristics such as spray penetration length, spray angle and fluid flow were observe under various operating conditions. Results show that increase in injection pressure increases the spray penetration length for both biodiesel and diesel. Results also indicate that higher spray angle of biodiesel can be seen as the injection pressure increases. This study concludes that spray characteristics of biodiesel blend is greatly affected by the injection and ambient conditions.

  5. Arc spray process for the aircraft and stationary gas turbine industry

    NASA Astrophysics Data System (ADS)

    Sampson, E. R.; Zwetsloot, M. P.

    1997-06-01

    Technological advances in arc spray have produced a system that competes favorably with other thermal spray processes. In the past, arc spray was thought of as a process for very large parts that need thick buildups. However, an attachment device known as the arc jet system has been developed that focuses the pattern and accelerates the particles. This attachment device, coupled with the in-troduction of metal-cored wires that provide the same chemistries as plasma-sprayed powders, pro-vides application engineers with a viable economic alternative to existing spray methods. A comparative evaluation of a standard production plasma spray system was conducted with the arc spray process using the attachment device. This evaluation was conducted by an airline company on four major parts coated with nickel-aluminum. Results show that, for these applications, the arc spray process offers several benefits.

  6. Field evaluation of a self-propelled sprayer and effects of the application rate on spray deposition and losses to the ground in greenhouse tomato crops.

    PubMed

    Sánchez-Hermosilla, Julián; Rincón, Víctor J; Páez, Francisco; Agüera, Francisco; Carvajal, Fernando

    2011-08-01

    In the greenhouses of south-eastern Spain, plant protection products are applied using mainly sprayers at high pressures and high volumes. This results in major losses on the ground and less than uniform spray deposition on the canopy. Recently, self-propelled vehicles equipped with vertical spray booms have appeared on the market. In this study, deposition on the canopy and the losses to the ground at different spray volumes have been compared, using a self-propelled vehicle with vertical spray booms versus a gun sprayer. Three different spray volumes have been tested with a boom sprayer, and two with a spray gun. The vehicle with the vertical spray boom gave similar depositions to those made with the gun, but at lower application volumes. Also, the distribution of the vertical spray boom was more uniform, with lower losses to the ground. The vertical spray booms used in tomato crops improve the application of plant protection products with respect to the spray gun, reducing the application volumes and the environmental risks of soil pollution. Copyright © 2011 Society of Chemical Industry.

  7. Nanosized aerosols from consumer sprays: experimental analysis and exposure modeling for four commercial products

    NASA Astrophysics Data System (ADS)

    Lorenz, Christiane; Hagendorfer, Harald; von Goetz, Natalie; Kaegi, Ralf; Gehrig, Robert; Ulrich, Andrea; Scheringer, Martin; Hungerbühler, Konrad

    2011-08-01

    Consumer spray products are already on the market in the cosmetics and household sector, which suggest by their label that they contain engineered nanoparticles (ENP). Sprays are considered critical for human health, because the lungs represent a major route for the uptake of ENP into the human body. To contribute to the exposure assessment of ENP in consumer spray products, we analyzed ENP in four commercially available sprays: one antiperspirant, two shoe impregnation sprays, and one plant-strengthening agent. The spray dispersions were analyzed by inductively coupled plasma mass spectrometry (ICPMS) and (scanning-) transmission electron microscopy ((S)TEM). Aerosols were generated by using the original vessels, and analyzed by scanning mobility particle sizer (SMPS) and (S)TEM. On the basis of SMPS results, the nanosized aerosol depositing in the respiratory tract was modeled for female and male consumers. The derived exposure levels reflect a single spray application. We identified ENP in the dispersions of two products (shoe impregnation and plant spray). Nanosized aerosols were observed in three products that contained propellant gas. The aerosol number concentration increased linearly with the sprayed amount, with the highest concentration resulting from the antiperspirant. Modeled aerosol exposure levels were in the range of 1010 nanosized aerosol components per person and application event for the antiperspirant and the impregnation sprays, with the largest fraction of nanosized aerosol depositing in the alveolar region. Negligible exposure from the application of the plant spray (pump spray) was observed.

  8. A Multiple-Dose, Randomized, Double-Blind, Placebo-Controlled, Parallel-Group QT/QTc Study to Evaluate the Electrophysiologic Effects of THC/CBD Spray.

    PubMed

    Sellers, Edward M; Schoedel, Kerri; Bartlett, Cindy; Romach, Myroslava; Russo, Ethan B; Stott, Colin G; Wright, Stephen; White, Linda; Duncombe, Paul; Chen, Chien-Feng

    2013-07-01

    Delta-9-tetrahydrocannabinol (THC)/cannabidiol (CBD) oromucosal spray has proved efficacious in the treatment of spasticity in multiple sclerosis and chronic pain. A thorough QT/QTc study was performed to investigate the effects of THC/CBD spray on electrocardiogram (ECG) parameters in compliance with regulatory requirements, evaluating the effect of a recommended daily dose (8 sprays/day) and supratherapeutic doses (24 or 36 sprays/day) of THC/CBD spray on the QT/QTc interval in 258 healthy volunteers. The safety, tolerability, and pharmacokinetic profile of THC/CBD spray were also evaluated. Therapeutic and supratherapeutic doses of THC/CBD spray had no effect on cardiac repolarization with primary and secondary endpoints of QTcI and QTcF/QTcB, respectively, showing similar results. There was no indication of any effect on heart rate, atrioventricular conduction, or cardiac depolarization and no new clinically relevant morphological changes were observed. Overall, 19 subjects (25.0%) in the supratherapeutic (24/36 daily sprays of THC/CBD spray) dose group and one (1.6%) in the moxifloxacin group withdrew early due to intolerable AEs. Four psychiatric serious adverse events (AEs) in the highest dose group resulted in a reduction in the surpatherapeutic dose to 24 sprays/day. In conclusion, THC/CBD spray does not significantly affect ECG parameters. Additionally, THC/CBD spray is well tolerated at therapeutic doses with an AE profile similar to previous clinical studies. © The Author(s) 2013.

  9. Determining Historical Pesticide Deposition on Cape Cod through Sediment Core Analysis:A Validation of GIS as An Exposure Assessment Tool

    NASA Astrophysics Data System (ADS)

    Feingold, B. J.; Benoit, G.; Rudel, R.

    2006-12-01

    Geographic Information Systems (GIS) has emerged as a powerful tool to assess current and historical exposure to environmental pollutants. GIS aids in the visualization and understanding of associations between exposure to contaminants and disease. This study is an example of the bridge between environmental science and public health and of how new technology such as GIS can be incorporated into these fields to strengthen both the research and the communication of scientific results. It attempts to validate a GIS-based aerial drift model which predicts the residential exposure to and boundaries of historical organochlorine pesticide (OCP) drift from applications on cranberry bogs, tree pest sprayings and others by analytically quantifying the historical pesticide deposition in a transect of lakes radiating from a distinct spray source. This model was previously used to assess historical residential exposure to OCPs in an environmental epidemiological case-control study of breast cancer incidence on Cape Cod, MA, where the incidence rate of the disease is significantly higher than in the rest of the state. The model's validation in this current study is essential to establishing its predictive ability and thus, its further use. Ground truthing of the model was done through the collection and analysis of sediment cores along a transect of five hydrologically independent kettle ponds radiating from a distinct OCP tree-pest spray area. Measurements of OCP concentrations, total carbon and total organic carbon were determined, and dating of the sediments was completed using 210Pb and verified using 137Cs. Each 50-cm core was sliced into 25 2- cm sections for the analyses, creating a fine-scale depositional history in each pond. Information gathered from each core allows for the determination of the extent and degree of dissipation of individual spray events of a known source area and determine how well the model fits the actual data.

  10. Visualisation of diesel injector with neutron imaging

    NASA Astrophysics Data System (ADS)

    Lehmann, E.; Grünzweig, C.; Jollet, S.; Kaiser, M.; Hansen, H.; Dinkelacker, F.

    2015-12-01

    The injection process of diesel engines influences the pollutant emissions. The spray formation is significantly influenced by the internal flow of the injector. One of the key parameters here is the generation of cavitation caused by the geometry and the needle lift. In modern diesel engines the injection pressure is established up to 3000 bar. The details of the flow and phase change processes inside the injector are of increasing importance for such injectors. With these experimental measurements the validation of multiphase and cavitation models is possible for the high pressure range. Here, for instance, cavitation effects can occur. Cavitation effects in the injection port area destabilize the emergent fuel jet and improve the jet break-up. The design of the injection system in direct-injection diesel engines is an important challenge, as the jet breakup, the atomization and the mixture formation in the combustion chamber are closely linked. These factors have a direct impact on emissions, fuel consumption and performance of an engine. The shape of the spray at the outlet is determined by the internal flow of the nozzle. Here, geometrical parameters, the injection pressure, the injection duration and the cavitation phenomena play a major role. In this work, the flow dependency in the nozzles are analysed with the Neutron-Imaging. The great advantage of this method is the penetrability of the steel structure while a high contrast to the fuel is given due to the interaction of the neutrons with the hydrogen amount. Compared to other methods (optical with glass structures) we can apply real components under highest pressure conditions. During the steady state phase of the injection various cavitation phenomena are visible in the injector, being influenced by the nozzle geometry and the fuel pressure. Different characteristics of cavitation in the sac and spray hole can be detected, and the spray formation in the primary breakup zone is influenced.

  11. The influence of menthol on thermoregulation and perception during exercise in warm, humid conditions.

    PubMed

    Gillis, D Jason; House, James R; Tipton, Michael J

    2010-10-01

    Menthol has recently been added to various cooling products that claim to enhance athletic performance. This study assessed the effect of two such solutions during exercise in warm, humid conditions. Twelve participants (22 ± 2.9 years; VO2peak 47.4 ± 6.2 mL kg(-1) min(-1)) completed a peak power (PO(peak)) test and three separate exercise bouts in 30°C and 70% relative humidity after being sprayed with 100 mL of water containing either 0.05 or 0.2% l-menthol, or a control spray. During each trial, participants underwent 15 min of rest, spraying, 15 min of rest and 45 min of exercise at 45% of PO(peak). The following variables were measured: rectal temperature (T (re)), sweat rate (SR), skin blood flow (SBF), heart rate (HR), thermal comfort (TC) and sensation (TS) votes, irritation (IRR) and rating of perceived exertion (RPE). Mean skin (MST) and body temperatures (Tbody) were calculated. There was no significant difference in MST, Tbody SR, SBF, HR, TC or RPE between conditions. Spraying with 0.2% menthol significantly (P < 0.05) elevated T (re) by 0.2°C compared to the other conditions. Both menthol sprays caused participants to feel significantly cooler than control spraying (P = 0.001), but 0.2% spraying induced significantly cooler sensations (P = 0.01) than 0.05% spraying. Both menthol sprays induced greater irritation (P < 0.001) than control spraying. These findings suggest that 0.05% menthol spraying induced cooler upper body sensations without measurable thermoregulatory impairment. T (re) was significantly elevated with 0.2% spraying. Irritation persisted with both menthol sprays while TC remained unchanged, suggesting a causal relationship. The use in sport of a spray similar to those tested here remains equivocal.

  12. Modeling metal droplet sprays in spray forming

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Muoio, N.G.; Crowe, C.T.; Fritsching, U.

    1995-12-31

    Spray casting is a process whereby a molten metal stream is atomized and deposited on a substrate. The rapid solidification of the metal droplets gives rise to a fine grain structure and improved material properties. This paper presents a simulation for the fluid and thermal interaction of the fluid and droplets in the spray and the effect on the droplet spray pattern. Good agreement is obtained between the measured and predicted droplet mass flux distribution in the spray.

  13. A User-Friendly Model for Spray Drying to Aid Pharmaceutical Product Development

    PubMed Central

    Grasmeijer, Niels; de Waard, Hans; Hinrichs, Wouter L. J.; Frijlink, Henderik W.

    2013-01-01

    The aim of this study was to develop a user-friendly model for spray drying that can aid in the development of a pharmaceutical product, by shifting from a trial-and-error towards a quality-by-design approach. To achieve this, a spray dryer model was developed in commercial and open source spreadsheet software. The output of the model was first fitted to the experimental output of a Büchi B-290 spray dryer and subsequently validated. The predicted outlet temperatures of the spray dryer model matched the experimental values very well over the entire range of spray dryer settings that were tested. Finally, the model was applied to produce glassy sugars by spray drying, an often used excipient in formulations of biopharmaceuticals. For the production of glassy sugars, the model was extended to predict the relative humidity at the outlet, which is not measured in the spray dryer by default. This extended model was then successfully used to predict whether specific settings were suitable for producing glassy trehalose and inulin by spray drying. In conclusion, a spray dryer model was developed that is able to predict the output parameters of the spray drying process. The model can aid the development of spray dried pharmaceutical products by shifting from a trial-and-error towards a quality-by-design approach. PMID:24040240

  14. DEVELOPMENT OF EMERGING TECHNOLOGIES WITHIN THE SITE PROGRAM

    EPA Science Inventory

    The Site Program is formed by five research programs: the Demonstration Program, the Emerging Technology Program, the Measurement and Monitoring Technology Development Program, the Innovative Technology Program, and the Technology Transfer Program. The Emerging Technology (ET) P...

  15. 46 CFR 34.25-20 - Spray nozzles-T/ALL.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 1 2010-10-01 2010-10-01 false Spray nozzles-T/ALL. 34.25-20 Section 34.25-20 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY TANK VESSELS FIREFIGHTING EQUIPMENT Water Spray Extinguishing Systems, Details § 34.25-20 Spray nozzles—T/ALL. (a) Spray nozzles shall be of an approved type. ...

  16. 46 CFR 34.25-20 - Spray nozzles-T/ALL.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 1 2011-10-01 2011-10-01 false Spray nozzles-T/ALL. 34.25-20 Section 34.25-20 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY TANK VESSELS FIREFIGHTING EQUIPMENT Water Spray Extinguishing Systems, Details § 34.25-20 Spray nozzles—T/ALL. (a) Spray nozzles shall be of an approved type. ...

  17. 77 FR 40550 - Approval and Promulgation of Air Quality Implementation Plans; Maryland; Revision for the Control...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-10

    ... filtered spray booth and enclosed spray gun cleaner. Maryland's 1997 SIP-approved regulation COMAR 26.11.19... equipment and materials storage such as spray booths, spray guns, and sealed containers for cleaning rags... standards include procedures for cleaning the spray gun equipment for applying automotive coatings. Affected...

  18. Effects of spray mixtures on droplet size under aerial application conditions and implications on drift

    USDA-ARS?s Scientific Manuscript database

    The use of simulated and mimic sprays for atomization studies in high speed wind tunnels allows researchers to limit the amount of active ingredients used in spray tests; however, it is important that these simulated and mimic sprays have the same physical and atomization characteristics of spray co...

  19. Electrostatic spraying in the chemical control of Triozoida limbata (Enderlein) (Hemiptera: Triozidae) in guava trees (Psidium guajava L.).

    PubMed

    Tavares, Rafael M; Cunha, João Par; Alves, Thales C; Bueno, Mariana R; Silva, Sérgio M; Zandonadi, César Hs

    2017-06-01

    Owing to the difficulty in reaching targets during pesticide applications on guava trees, it is important to evaluate new technologies that may improve pest management. In electrostatic spraying, an electric force is added to the droplets to control their movements such that they are efficiently directed to the target. The present study evaluated the performance of electrostatic and non-electrostatic spraying in the control of the guava psyllid, the deposition of the spray mixture on the leaves and the losses to the soil. The deposition of the spray mixture was up to 2 times greater when using electrostatic spraying in comparison with non-electrostatic application. The losses of the spray mixture to the soil were up to 4 times smaller with the electrostatic spraying. Electrostatic spraying had better control of the psyllid. It was possible to reduce the volume rate of application with electrostatic spraying without adversely affecting the control of the guava psyllid. © 2016 Society of Chemical Industry. © 2016 Society of Chemical Industry.

  20. Futurepath: The Story of Research and Technology at NASA Lewis Research Center. Structures for Flight Propulsion, ARC Sprayed Monotape, National Aero-Space Plane

    NASA Technical Reports Server (NTRS)

    1989-01-01

    The story of research and technology at NASA Lewis Research Center's Structures Division is presented. The job and designs of the Structures Division needed for flight propulsion is described including structural mechanics, structural dynamics, fatigue, and fracture. The video briefly explains why properties of metals used in structural mechanics need to be tested. Examples of tests and simulations used in structural dynamics (bodies in motion) are briefly described. Destructive and non-destructive fatigue/fracture analysis is also described. The arc sprayed monotape (a composite material) is explained, as are the programs in which monotape plays a roll. Finally, the National Aero-Space Plane (NASP or x-30) is introduced, including the material development and metal matrix as well as how NASP will reduce costs for NASA.

  1. PRA (Probabilistic Risk Assessment) Applications Program for inspection at Oconee Unit 3

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gore, B.F.; Vo, T.V.; Harris, M.S.

    1987-10-01

    The extensive Oconee-3 PRA performed by EPRI has been analyzed to identify plant systems and components important to minimizing public risk, and to identify the primary failure modes of these components. This information has been tabulated, and correlated with inspection modules from the NRC Inspection and Enforcement Manual. The report presents a series of tables, organized by system and prioritized by public risk (in person-rem per year), which identify components associated with 98% of the inspectable risk due to plant operation. External events (earthquakes, tornadoes, fires and floods) are not addressed because inspections cannot directly minimize the risks from thesemore » events; however, flooding caused by the breach of internal systems is addressed. The systems addressed, in descending order of risk importance, are: Reactor Building Spray, R B Cooling, Condenser Circulating Water, Safety Relief Valves, Low Pressure Injection, Standby Shutdown Facility-High Pressure Injection, Low-Pressure Service Water, and Emergency Feedwater. This ranking is based on the Fussel-Vesely measure of risk importance, i.e., the fraction of the total risk which involves failures of the system of interest. 8 refs., 25 tabs.« less

  2. A laser tomographic investigation of liquid fuel sprays

    NASA Technical Reports Server (NTRS)

    Yule, A. J.; Ahseng, C.; Felton, P.; Ungut, A.; Chigier, N. A.

    1980-01-01

    A light scattering technique is combined with a tomographic transformation to convert line of sight integrated data, measured in sprays, to measurements of droplet size and concentration in volume elements within the spray. The technique is developed and assessed by systematic experiments in axisymmetric sprays generated by twin-fluid atomisers. The good agreement found shows that, provided certain conditions are satisfied by the local spray structure, the technique provides information on spray structure, similar in detail and extent to that derived by photography, but with reduced experimental time. The technique is applied to an investigation of a kerosene spray vaporizing in a hot gas stream.

  3. Measurements in liquid fuel sprays

    NASA Technical Reports Server (NTRS)

    Chigier, N.

    1984-01-01

    Techniques for studying the events directly preceding combustion in the liquid fuel sprays are being used to provide information as a function of space and time on droplet size, shape, number density, position, angle of flight and velocity. Spray chambers were designed and constructed for: (1) air-assist liquid fuel research sprays; (2) high pressure and temperature chamber for pulsed diesel fuel sprays; and (3) coal-water slurry sprays. Recent results utilizing photography, cinematography, and calibration of the Malvern particle sizer are reported. Systems for simultaneous measurement of velocity and particle size distributions using laser Doppler anemometry interferometry and the application of holography in liquid fuel sprays are being calibrated.

  4. Effects of nasal drug delivery device and its orientation on sprayed particle deposition in a realistic human nasal cavity.

    PubMed

    Tong, Xuwen; Dong, Jingliang; Shang, Yidan; Inthavong, Kiao; Tu, Jiyuan

    2016-10-01

    In this study, the effects of nasal drug delivery device and the spray nozzle orientation on sprayed droplets deposition in a realistic human nasal cavity were numerically studied. Prior to performing the numerical investigation, an in-house designed automated actuation system representing mean adults actuation force was developed to produce realistic spray plume. Then, the spray plume development was filmed by high speed photography system, and spray characteristics such as spray cone angle, break-up length, and average droplet velocity were obtained through off-line image analysis. Continuing studies utilizing those experimental data as boundary conditions were applied in the following numerical spray simulations using a commercially available nasal spray device, which was inserted into a realistic adult nasal passage with external facial features. Through varying the particle releasing direction, the deposition fractions of selected particle sizes on the main nasal passage for targeted drug delivery were compared. The results demonstrated that the middle spray direction showed superior spray efficiency compared with upper or lower directions, and the 10µm agents were the most suitable particle size as the majority of sprayed agents can be delivered to the targeted area, the main passage. This study elaborates a comprehensive approach to better understand nasal spray mechanism and evaluate its performance for existing nasal delivery practices. Results of this study can assist the pharmaceutical industry to improve the current design of nasal drug delivery device and ultimately benefit more patients through optimized medications delivery. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Influence of handpiece maintenance sprays on resin bonding to dentin.

    PubMed

    Sugawara, Toyotarou; Kameyama, Atsushi; Haruyama, Akiko; Oishi, Takumi; Kukidome, Nobuyuki; Takase, Yasuaki; Tsunoda, Masatake

    2010-01-01

    To investigate the influence of maintenance spray on resin bonding to dentin. The crown of extracted, caries-free human molars was transversally sectioned with a model trimmer to prepare the dentin surfaces from mid-coronal sound dentin, and then uniformly abraded with #600 silicon carbide paper. The dentin surfaces were randomly divided into three groups: oil-free spray group where maintenance cleaner for air bearing handpieces was sprayed onto the dentin surface for 1 s and rinsed with water spray for 30 s; oil-containing spray group where maintenance cleaner for micro motor handpieces was sprayed onto the dentin surface for 1 s and rinsed with water spray for 30 s; and control group where the surface was rinsed with water spray for 30 s and then air-dried. These surfaces were then bonded with Clearfil SE Bond (Kuraray Medical), and resin composite (Clearfil AP-X, Kuraray Medical) build-up crowns were incrementally constructed on the bonded surfaces. After storage for 24 h in 37°C water, the bonded teeth were sectioned into hour-glass shaped slices (0.7-mm thick) perpendicular to the bonded surfaces. The specimens were then subjected to microtensile bond strength (μTBS) testing at a crosshead speed of 1.0 mm/min. Data were analyzed with one-way ANOVA and the Tukey-Kramer test. Maintenance spray-contaminated specimens (oil-free and oil-containing spray groups) showed significantly lower μTBS than control specimens (P < 0.05). However, there was no significant difference between the spray-contaminated groups (P > 0.05). Maintenance spray significantly reduces the bond strength of Clearfil SE Bond to dentin.

  6. Drive Fan of the NACA's Icing Research Tunnel

    NASA Image and Video Library

    1956-10-21

    A researcher examines the drive fan inside the Icing Research Tunnel at the National Advisory Committee for Aeronautics (NACA) Flight Propulsion Research Laboratory in Cleveland, Ohio. The facility was built in the mid-1940s to simulate the atmospheric conditions that caused ice to build up on aircraft. Carrier Corporation refrigeration equipment reduced the internal air temperature to -45⁰ F, and a spray bar system injected water droplets into the air stream. The 24-foot diameter drive fan, seen in this photograph, created air flow velocities up to 400 miles per hour. The 1950s were prime years for the Icing Research Tunnel. NACA engineers had spent the 1940s trying to resolve the complexities of the spray bar system. The final system put into operation in 1950 included six horizontal spray bars with 80 nozzles that produced a 4- by 4-foot cloud in the test section. The icing tunnel was used for extensive testing of civilian and military aircraft components in the 1950s. The NACA also launched a major investigation of the various methods of heating leading edge surfaces. The hot-air anti-icing technology used on today’s commercial transports was largely developed in the facility during this period. Lewis researchers also made significant breakthroughs with icing on radomes and jet engines. Although the Icing Research Tunnel yielded major breakthroughs in the 1950s, the Lewis icing research program began tapering off as interest in the space program grew. The icing tunnel’s use declined in 1956 and 1957. The launch of Sputnik in October 1957 signaled the end of the facility’s operation. The icing staff was transferred to other research projects and the icing tunnel was temporarily mothballed.

  7. CFD Simulation of Aerial Crop Spraying

    NASA Astrophysics Data System (ADS)

    Omar, Zamri; Qiang, Kua Yong; Mohd, Sofian; Rosly, Nurhayati

    2016-11-01

    Aerial crop spraying, also known as crop dusting, is made for aerial application of pesticides or fertilizer. An agricultural aircraft which is converted from an aircraft has been built to combine with the aerial crop spraying for the purpose. In recent years, many studies on the aerial crop spraying were conducted because aerial application is the most economical, large and rapid treatment for the crops. The main objective of this research is to study the airflow of aerial crop spraying system using Computational Fluid Dynamics. This paper is focus on the effect of aircraft speed and nozzle orientation on the distribution of spray droplet at a certain height. Successful and accurate of CFD simulation will improve the quality of spray during the real situation and reduce the spray drift. The spray characteristics and efficiency are determined from the calculated results of CFD. Turbulence Model (k-ɛ Model) is used for the airflow in the fluid domain to achieve a more accurate simulation. Furthermore, spray simulation is done by setting the Flat-fan Atomizer Model of Discrete Phase Model (DPM) at the nozzle exit. The interaction of spray from each flat-fan atomizer can also be observed from the simulation. The evaluation of this study is validation and grid dependency study using field data from industry.

  8. Potential hazard of volatile organic compounds contained in household spray products

    NASA Astrophysics Data System (ADS)

    Rahman, Md Mahmudur; Kim, Ki-Hyun

    2014-03-01

    To assess the exposure levels of hazardous volatile pollutants released from common household spray products, a total of 10 spray products consisting of six body spray and four air spray products have been investigated. The body spray products included insect repellents (two different products), medicated patch, deodorant, hair spray, and humectant, whereas the air spray products included two different insecticides (mosquito and/or cockroach), antibacterial spray, and air freshener. The main objective of this study was to measure concentrations of 15 model volatile organic compounds (VOCs) using GC/MS coupled with a thermal desorber. In addition, up to 34 ‘compounds lacking authentic standards or surrogates (CLASS)' were also quantified based on the effective carbon number (ECN) theory. According to our analysis, the most common indoor pollutants like benzene, toluene, styrene, methyl ethyl ketone, and butyl acetate have been detected frequently in the majority of spray products with the concentration range of 5.3-125 mg L-1. If one assumes that the amount of spray products released into air reaches the 0.3 mL level for a given space size of 5 m3, the risk factor is expected to exceed the carcinogenic risk level set for benzene (10-5) by the U.S. EPA.

  9. Insights into Spray Development from Metered-Dose Inhalers Through Quantitative X-ray Radiography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mason-Smith, Nicholas; Duke, Daniel J.; Kastengren, Alan L.

    Typical methods to study pMDI sprays employ particle sizing or visible light diagnostics, which suffer in regions of high spray density. X-ray techniques can be applied to pharmaceutical sprays to obtain information unattainable by conventional particle sizing and light-based techniques. We present a technique for obtaining quantitative measurements of spray density in pMDI sprays. A monochromatic focused X-ray beam was used to perform quantitative radiography measurements in the near-nozzle region and plume of HFA-propelled sprays. Measurements were obtained with a temporal resolution of 0.184 ms and spatial resolution of 5 mu m. Steady flow conditions were reached after around 30more » ms for the formulations examined with the spray device used. Spray evolution was affected by the inclusion of ethanol in the formulation and unaffected by the inclusion of 0.1% drug by weight. Estimation of the nozzle exit density showed that vapour is likely to dominate the flow leaving the inhaler nozzle during steady flow. Quantitative measurements in pMDI sprays allow the determination of nozzle exit conditions that are difficult to obtain experimentally by other means. Measurements of these nozzle exit conditions can improve understanding of the atomization mechanisms responsible for pMDI spray droplet and particle formation.« less

  10. 40 CFR 63.11171 - How do I know if my source is considered a new source or an existing source?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... associated equipment; (3) Spray guns and associated equipment; (4) Spray gun cleaning equipment; (5... stripping or surface coating equipment. If you purchase and install spray booths, enclosed spray gun cleaners, paint stripping equipment to reduce MeCl emissions, or purchase new spray guns to comply with...

  11. Initial and continued effects of a release spray in a coastal Oregon Douglas-fir plantation.

    Treesearch

    Richard E. Miller; Edmund L. Obermeyer

    1996-01-01

    Portions of a 4-year-old Douglas-fir (Pseudotsuga menziesii var. menziesii (Mirb.) Franco) plantation were sprayed with herbicide. Five years after spraying, we established 18 plots and used several means to determine retrospectively that six plots probably received full spray treatment and six others received no spray. Various...

  12. Effect of formulated glyphosate and adjuvant tank mixes on atomization from aerial application flat fan nozzles

    USDA-ARS?s Scientific Manuscript database

    This study was designed to determine if the present USDA ARS Spray Nozzle models based on water plus non-ionic surfactant spray solutions could be used to estimate spray droplet size data for different spray formulations through use of experimentally determined correction factors or if full spray fo...

  13. CFD simulation of pesticide spray from air-assisted sprayers in an apple orchard: tree deposition and off-target losses

    USDA-ARS?s Scientific Manuscript database

    The ultimate goal of a pesticide spraying system is to provide adequate coverage on intended canopies with a minimum amount of spray materials and off-target waste. Better spray coverage requires an understanding of the fate and transport of spray droplets carried by turbulent airflows in orchards. ...

  14. Director's discretionary fund report for FY 1991

    NASA Technical Reports Server (NTRS)

    1992-01-01

    The Director's Discretionary Fund (DDF) at the Ames Research Center was established to fund innovative, high-risk projects in basic research which would otherwise be difficult to initiate, but which are essential to our future programs. Here, summaries are given of individual projects within this program. Topics covered include scheduling electric power for the Ames Research Center, the feasibility of light emitting diode arrays as a lighting source for plant growth chambers in space, plasma spraying of nonoxide coatings using a constricted arcjet, and the characterization of vortex impingement footprint using non-intrusive measurement techniques.

  15. Effect of aqueous sprays of ammonium fluoride on oxygen consumption and firmness of suture and dorsal tissues of Early Improved Elberta peaches. [Prunus persica

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Facteau, T.J.; Rowe, K.E.

    1976-06-01

    Aqueous ammonium fluoride (NH/sub 4/F) sprays on Early Improved Elberta peaches (Prunus persica (L.) Batsch) resulted in increased O/sub 2/ consumption of suture tissue and inconsistent changes in O/sub 2/ consumption of dorsal tissue as the spray concentration was increased. Flesh firmness on the suture side of treated fruit was less than non-sprayed fruit and decreased as either the NH/sub 4/F spray concentration or number of sprays increased. The effect of spray on the dorsal side differed from year to year. Levels of fluoride (F) in the fruit tissue were associated with F concentration and number of F sprays appliedmore » only within the same year. 3 references, 1 table.« less

  16. Defense Nanotechnology Research and Development Programs

    DTIC Science & Technology

    2005-05-17

    Laser has been achieved with SBIR support. • Thermal spray ceramic nanocomposite alumina - titania has been commercialized for wear resistant...additives have been developed that, during membrane formation, self-assemble a low-fouling hydrophilic surface on all membrane surfaces (both...macroscopic and pore surfaces). • A new method for processing of ceramic nanocomposites has been demonstrated, in which a homogeneous, metastable powder is

  17. Four engine aircraft experience in the application of Bacillus thuringiensis against the spruce budworm in Quebec

    Treesearch

    Louis Dorais

    1985-01-01

    I want, during this presentation, to give you a spray program coordinator point of view on Bt and try to explain why things are always different in Quebec. Not always better but always different, even in the application of Bacillus thuringiensis where 4 engine aircrafts were used to control the spruce budworm, Choristoneura funiferana...

  18. 40 CFR 60.105a - Monitoring of emissions and operations for fluid catalytic cracking units (FCCU) and fluid coking...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... for air leaks, torn or broken bags or filter media, or any other condition that may cause an increase... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF... nozzles must conduct a daily check of the air or water pressure to the spray nozzles and record the...

  19. Functional Analysis and Treatment of Rumination Using Fixed-Time Delivery of a Flavor Spray

    ERIC Educational Resources Information Center

    Wilder, David A.; Register, Martisa; Register, Stanley; Bajagic, Vedrana; Neidert, Pamela L.

    2009-01-01

    A functional analysis suggested that rumination exhibited by an adult with autism was maintained by automatic reinforcement. Next, a preference assessment with three flavor sprays (i.e., flavored sprays used by dieters) showed that apple pie spray was most preferred. Finally, the effects of fixed-time delivery of the apple pie spray on levels of…

  20. A numerical analysis of flat fan aerial crop spray

    NASA Astrophysics Data System (ADS)

    Malik Fesal, Siti Natasha; Fawzi, Mas; Omar, Zamri

    2017-09-01

    Spray drift mitigation, in the agriculture aerial spraying literature, and spray quality in the application of plant protection products, still continues as two critical components in evaluating shareholder value. A study on off-target drift and ground deposit onto a 250 m strip were simulated through series of Computational Fluid Dynamic (CFD) simulations. The drift patterns for evaporating droplets were released from a constant aircraft velocity at 30 m/s (60 mph) carrying 20 m swath width spray boom with 12 fan-type nozzles at released height from the ground ranging from 3.7 m to 4.7 m. Droplet trajectories are calculated from the given airspeed with a Lagrangian model for particle dispersion excluding any wind effect perturbation. The proposed CFD’s model predictions agreed well with cited literatures for a wide range of atmospheric stability values. The results revealed that there is considerable increased in spray drift and droplets trajectories with the increased in spray released height. It suggested that a combination of low aircraft spray released height with low airspeed is essential to improve spray quality and maximizing uniform deposition on the target area are significant in minimizing spray drift risks.

  1. Venom-spraying behavior of the scorpion Parabuthus transvaalicus (Arachnida: Buthidae).

    PubMed

    Nisani, Zia; Hayes, William K

    2015-06-01

    Many animals use chemical squirting or spraying behavior as a defensive response. Some members of the scorpion genus Parabuthus (family Buthidae) can spray their venom. We examined the stimulus control and characteristics of venom spraying by Parabuthus transvaalicus to better understand the behavioral context for its use. Venom spraying occurred mostly, but not always, when the metasoma (tail) was contacted (usually grasped by forceps), and was absent during stinging-like thrusts of the metasoma apart from contact. Scorpions were significantly more likely to spray when contact was also accompanied by airborne stimuli. Sprays happened almost instantaneously following grasping by forceps (median=0.23s) as a brief (0.07-0.30s, mean=0.18s), fine stream (<5° arc) that was not directed toward the stimulus source; however, rapid independent movements of the metasoma and/or telson (stinger) often created a more diffuse spray, increasing the possibility of venom contact with the sensitive eyes of potential scorpion predators. Successive venom sprays varied considerably in duration and velocity. Collectively, these results suggest that venom spraying might be useful as an antipredator function and can be modulated based on threat. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. Early change in thermal perception is not a driver of anticipatory exercise pacing in the heat.

    PubMed

    Barwood, Martin James; Corbett, Jo; White, Danny; James, Jason

    2012-10-01

    Initial power output declines significantly during exercise in hot conditions on attaining a rapid increase in skin temperature when exercise commences. It is unclear whether this initial reduced power is mediated consciously, through thermal perceptual cues, or is a subconscious process. The authors tested the hypothesis that improved thermal perception (feeling cooler and more comfortable) in the absence of a change in thermal state (ie, similar deep-body and skin temperatures between spray conditions) would alter pacing and 40 km cycling time trial (TT) performance. Eleven trained participants (mean (SD): age 30 (8.1) years; height 1.78 (0.06) m; mass 76.0 (8.3) kg) completed three 40 km cycling TTs in standardised conditions (32°C, 50% RH) with thermal perception altered prior to exercise by application of cold-receptor-activating menthol spray (MENTHOL SPRAY), in contrast to a separate control spray (CONTROL SPRAY) and no spray control (CON). Thermal perception, perceived exertion, thermal responses and cycling TT performance were measured. MENTHOL SPRAY induced feelings of coolness and improved thermal comfort before and during exercise. Skin temperature profile at the start of exercise was similar between sprays (CON-SPRAY 33.3 (1.1)°C and MENTHOL SPRAY 33.4 (0.4)°C, but different to CON 34.5 (0.5)°C), but there was no difference in the pacing strategy adopted. There was no performance benefit using MENTHOL SPRAY; cycling TT completion time for CON is 71.58 (6.21) min, for CON-SPRAY is 70.94 (6.06) min and for MENTHOL SPRAY is 71.04 (5.47) min. The hypothesis is rejected. Thermal perception is not a primary driver of early pacing during 40 km cycling TT in hot conditions in trained participants.

  3. An Experimental and Numerical Study of Diesel Spray Impingement on a Flat Plate

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhao, Le; Torelli, Roberto; Zhu, Xiucheng

    Combustion systems with advanced injection strategies have been extensively studied, but there still exists a significant fundamental knowledge gap on fuel spray interactions with the piston surface and chamber walls. This paper is meant to provide detailed data on spray-wall impingement physics and support the spray-wall model development. The experimental work of spray-wall impingement with non-vaporizing spray characterization, was carried out in a high pressure-temperature constant-volume combustion vessel. The simultaneous Mie scattering of liquid spray and schlieren of liquid and vapor spray were carried out. Diesel fuel was injected at a pressure of 1500 bar into ambient gas at amore » density of 22.8 kg/m3 with isothermal conditions (fuel, ambient, and plate temperatures of 423 K). A Lagrangian-Eulerian modeling approach was employed to characterize the spray-gas and spray-wall interactions in the CONVERGE framework by means of a Reynolds-Averaged Navier-Stokes (RANS) formulation. A set of turbulence and spray break-up model constants was identified to properly match the aforementioned measurements of liquid penetration within their experimental confidence intervals. An accuracy study on varying the minimum mesh size was also performed to ensure the grid convergence of the numerical results. Experimentally validated computational fluid dynamics (CFD) simulations were then used to investigate the local spray characteristics in the vicinity of the wall with a particular focus on Sauter Mean Diameter (SMD) and Reynolds and Weber numbers. The analysis was performed by considering before- and after-impingement conditions in order to take in account the influence of the impinged wall on the spray morphology.« less

  4. Turbulent dispersion of the icing cloud from spray nozzles used in icing tunnels

    NASA Technical Reports Server (NTRS)

    Marek, C. J.; Olsen, W. A., Jr.

    1986-01-01

    To correctly simulate flight in natural icing conditions, the turbulence in an icing simulator must be as low as possible. But some turbulence is required to mix the droplets from the spray nozzles and achieve an icing cloud of uniform liquid water content. The goal for any spray system is to obtain the widest possible spray cloud with the lowest possible turbulence in the test section of a icing tunnel. This investigation reports the measurement of turbulence and the three-dimensional spread of the cloud from a single spray nozzle. The task was to determine how the air turbulence and cloud width are affected by spray bars of quite different drag coefficients, by changes in the turbulence upstream of the spray, the droplet size, and the atomizing air. An ice accretion grid, located 6.3 m downstream of the single spray nozzle, was used to measure cloud spread. Both the spray bar and the grid were located in the constant velocity test section. Three spray bar shapes were tested: the short blunt spray bar used in the NASA Lewis Icing Research Tunnel, a thin 14.6 cm chord airfoil, and a 53 cm chord NACA 0012 airfoil. At the low airspeed (56 km/hr) the ice accretion pattern was axisymmetric and was not affected by the shape of the spray bar. At the high airspeed (169 km/hr) the spread was 30 percent smaller than at the low airspeed. For the widest cloud the spray bars should be located as far upstream in the low velocity plenum of the icing tunnel. Good comparison is obtained between the cloud spread data and predicitons from a two-dimensional cloud mixing computer code using the two equation turbulence (k epsilon g) model.

  5. Solid-state, triboelectrostatic and dissolution characteristics of spray-dried piroxicam-glucosamine solid dispersions.

    PubMed

    Adebisi, Adeola O; Kaialy, Waseem; Hussain, Tariq; Al-Hamidi, Hiba; Nokhodchi, Ali; Conway, Barbara R; Asare-Addo, Kofi

    2016-10-01

    This work explores the use of both spray drying and d-glucosamine HCl (GLU) as a hydrophilic carrier to improve the dissolution rate of piroxicam (PXM) whilst investigating the electrostatic charges associated with the spray drying process. Spray dried PXM:GLU solid dispersions were prepared and characterised (XRPD, DSC, SEM). Dissolution and triboelectric charging were also conducted. The results showed that the spray dried PXM alone, without GLU produced some PXM form II (DSC results) with no enhancement in solubility relative to that of the parent PXM. XRPD results also showed the spray drying process to decrease the crystallinity of GLU and solid dispersions produced. The presence of GLU improved the dissolution rate of PXM. Spray dried PXM: GLU at a ratio of 2:1 had the most improved dissolution. The spray drying process generally yielded PXM-GLU spherical particles of around 2.5μm which may have contributed to the improved dissolution. PXM showed a higher tendency for charging in comparison to the carrier GLU (-3.8 versus 0.5nC/g for untreated material and -7.5 versus 3.1nC/g for spray dried materials). Spray dried PXM and spray dried GLU demonstrated higher charge densities than untreated PXM and untreated GLU, respectively. Regardless of PXM:GLU ratio, all spray dried PXM:GLU solid dispersions showed a negligible charge density (net-CMR: 0.1-0.3nC/g). Spray drying of PXM:GLU solid dispersions can be used to produce formulation powders with practically no charge and thereby improving handling as well as dissolution behaviour of PXM. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Design Optimization of Liquid Fueled High Velocity Oxy- Fuel Thermal Spraying Technique for Durable Coating for Fossil Power Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Choudhuri, Ahsan; Love, Norman

    High-velocity oxy–fuel (HVOF) thermal spraying was developed in 1930 and has been commercially available for twenty-five years. HVOF thermal spraying has several benefits over the more conventional plasma spray technique including a faster deposition rate which leads to quicker turn-around, with more durable coatings and higher bond strength, hardness and wear resistance due to a homogeneous distribution of the sprayed particles. HVOF thermal spraying is frequently used in engineering to deposit cermets, metallic alloys, composites and polymers, to enhance product life and performance. HVOF thermal spraying system is a highly promising technique for applying durable coatings on structural materials formore » corrosive and high temperature environments in advanced ultra-supercritical coal- fired (AUSC) boilers, steam turbines and gas turbines. HVOF thermal spraying is the preferred method for producing coatings with low porosity and high adhesion. HVOF thermal spray process has been shown to be one of the most efficient techniques to deposit high performance coatings at moderate cost. Variables affecting the deposit formation and coating properties include hardware characteristics such as nozzle geometry and spraying distance and process parameters such as equivalence ratio, gas flow density, and powder feedstock. In the spray process, the powder particles experience very high speeds combined with fast heating to the powder material melting point or above. This high temperature causes evaporation of the powder, dissolution, and phase transformations. Due to the complex nature of the HVOF technique, the control and optimization of the process is difficult. In general, good coating quality with suitable properties and required performance for specific applications is the goal in producing thermal spray coatings. In order to reach this goal, a deeper understanding of the spray process as a whole is needed. Although many researchers studied commercial HVOF thermal spray systems, there exists a lack of fundamental understanding of the effect of hardware characteristics and operating parameters on HVOF thermally sprayed coatings. Motivated by these issues, this study is devoted to investigate the effect of hardware characteristics (e.g. spraying distance) and operating parameters (e.g. combustion chamber pressure, equivalence ratio, and total gas flow rate) on HVOF sprayed coatings using Inconel 718 alloy. The current study provides extensive understanding of several key operating and process parameters to optimize the next generation of HVOF thermally sprayed coatings for high temperature and harsh environment applications. A facility was developed to support this endeavor in a safe and efficient way, including a HVOF thermal spray system with a Data Acquisition and Remote Controls system (DARCS). The coatings microstructure and morphology were examined using X-Ray Diffraction (XRD), Scanning Electron Microscope (SEM) and Nanoindentation.« less

  7. Water spray ventilator system for continuous mining machines

    DOEpatents

    Page, Steven J.; Mal, Thomas

    1995-01-01

    The invention relates to a water spray ventilator system mounted on a continuous mining machine to streamline airflow and provide effective face ventilation of both respirable dust and methane in underground coal mines. This system has two side spray nozzles mounted one on each side of the mining machine and six spray nozzles disposed on a manifold mounted to the underside of the machine boom. The six spray nozzles are angularly and laterally oriented on the manifold so as to provide non-overlapping spray patterns along the length of the cutter drum.

  8. Low pressure cold spraying on materials with low erosion resistance

    NASA Astrophysics Data System (ADS)

    Shikalov, V. S.; Klinkov, S. V.; Kosarev, V. F.

    2017-10-01

    In present work, the erosion-adhesion transition was investigated during cold spraying of aluminum particles on brittle ceramic substrates. Cold spraying was carried out with aid of sonic nozzle, which use allows significantly reducing the gas stagnation pressure without the effect of flow separation inside the nozzle and, accordingly, reducing the velocity of the spraying particles. Two stagnation pressures were chosen. The coating tracks were sprayed at different air temperatures in nozzle pre-chamber under each of regimes. Single sprayed tracks were obtained and their profiles were investigated by optical profilometry.

  9. Simulation of preburner sprays, volumes 1 and 2

    NASA Technical Reports Server (NTRS)

    Hardalupas, Y.; Whitelaw, J. H.

    1993-01-01

    The present study considered characteristics of sprays under a variety of conditions. Control of these sprays is important as the spray details can control both rocket combustion stability and efficiency. Under the present study Imperial College considered the following: (1) Measurement of the size and rate of spread of the sprays produced by single coaxial airblast nozzles with axial gaseous stream. The local size, velocity, and flux characteristics for a wide range of gas and liquid flowrates were measured, and the results were correlated with the conditions of the spray at the nozzle exit. (2) Examination of the effect of the geometry of single coaxial airblast atomizers on spray characteristics. The gas and liquid tube diameters were varied over a range of values, the liquid tube recess was varied, and the shape of the exit of the gaseous jet was varied from straight to converging. (3) Quantification of the effect of swirl in the gaseous stream on the spray characteristics produced by single coaxial airblast nozzles. (4) Quantification of the effect of reatomization by impingement of the spray on a flat disc positioned around 200 mm from the nozzle exit. This models spray impingement on the turbopump dome during the startup process of the preburner of the SSME. (5) Study of the interaction between multiple sprays without and with swirl in their gaseous stream. The spray characteristics of single nozzles were compared with that of three identical nozzles with their axis at a small distance from each other. This study simulates the sprays in the preburner of the SSME, where there are around 260 elements on the faceplate of the combustion chamber. (6) Design an experimental facility to study the characteristics of sprays at high pressure conditions and at supercritical pressure and temperature for the gas but supercritical pressure and subcritical temperature for the liquid.

  10. Optimization of the inter-tablet coating uniformity for an active coating process at lab and pilot scale.

    PubMed

    Just, Sarah; Toschkoff, Gregor; Funke, Adrian; Djuric, Dejan; Scharrer, Georg; Khinast, Johannes; Knop, Klaus; Kleinebudde, Peter

    2013-11-30

    The objective of this study was to enhance the inter-tablet coating uniformity in an active coating process at lab and pilot scale by statistical design of experiments. The API candesartan cilexetil was applied onto gastrointestinal therapeutic systems containing the API nifedipine to obtain fixed dose combinations of these two drugs with different release profiles. At lab scale, the parameters pan load, pan speed, spray rate and number of spray nozzles were examined. At pilot scale, the parameters pan load, pan speed, spray rate, spray time, and spray pressure were investigated. A low spray rate and a high pan speed improved the coating uniformity at both scales. The number of spray nozzles was identified as the most influential variable at lab scale. With four spray nozzles, the highest CV value was equal to 6.4%, compared to 13.4% obtained with two spray nozzles. The lowest CV of 4.5% obtained with two spray nozzles was further reduced to 2.3% when using four spray nozzles. At pilot scale, CV values between 2.7% and 11.1% were achieved. Since the test of uniformity of dosage units accepts CV values of up to 6.25%, this active coating process is well suited to comply with the pharmacopoeial requirements. Copyright © 2013 Elsevier B.V. All rights reserved.

  11. The effect of a simple annealing heat treatment on the mechanical properties of cold-sprayed aluminum

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hall, Aaron Christopher; Roemer, Timothy John; Hirschfeld, Deidre A.

    2004-11-01

    Cold spray, a new member of the thermal spray process family, can be used to prepare dense, thick metal coatings. It has tremendous potential as a spray-forming process. However, it is well known that significant cold work occurs during the cold spray deposition process. This cold work results in hard coatings but relatively brittle bulk deposits. This work investigates the mechanical properties of cold-sprayed aluminum and the effect of annealing on those properties. Cold spray coatings approximately 1 cm thick were prepared using three different feedstock powders: Valimet H-10; Valimet H-20; and Brodmann Flomaster. ASTM E8 tensile specimens were machinedmore » from these coatings and tested using standard tensile testing procedures. Each material was tested in two conditions: as-sprayed; and after a 300 C, 22 h air anneal. The as-sprayed material showed high ultimate strength and low ductility, with <1% elongation. The annealed samples showed a reduction in ultimate strength but a dramatic increase in ductility, with up to 10% elongation. The annealed samples exhibited mechanical properties that were similar to those of wrought 1100 H14 aluminum. Microstructural examination and fractography clearly showed a change in fracture mechanism between the as-sprayed and annealed materials. These results indicate good potential for cold spray as a bulk-forming process.« less

  12. The effect of a simple annealing heat treatement on the mechanical properties of cold-sprayed aluminium.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hall, Aaron Christopher; Roemer, Timothy John; Hirschfeld, Deidre A.

    2005-08-01

    Cold spray, a new member of the thermal spray process family, can be used to prepare dense, thick metal coatings. It has tremendous potential as a spray-forming process. However, it is well known that significant cold work occurs during the cold spray deposition process. This cold work results in hard coatings but relatively brittle bulk deposits. This work investigates the mechanical properties of cold-sprayed aluminum and the effect of annealing on those properties. Cold spray coatings approximately 1 cm thick were prepared using three different feedstock powders: Valimet H-10: Valimet H-20: and Brodmann Flomaster. ASTM E8 tensile specimens were machinedmore » from these coatings and tested using standard tensile testing procedures. Each material was tested in two conditions: as-sprayed; and after a 300 C, 22h air anneal. The as-sprayed material showed high ultimate strength and low ductility, with <1% elongation. The annealed samples showed a reduction in ultimate strength but a dramatic increase in ductility, with up to 10% elongation. The annealed samples exhibited mechanical properties that were similar to those of wrought 1100 H14 aluminum. Microstructural examination and fractography clearly showed a change in fracture mechanism between the as-sprayed and annealed materials. These results indicate good potential for cold spray as a bulkforming process.« less

  13. Metsulfuron spray drift reduces fruit yield of hawthorn (Crataegus monogyna L.).

    PubMed

    Kjaer, Christian; Strandberg, Morten; Erlandsen, Mogens

    2006-03-01

    This study was carried out to investigate whether spray drift of metsulfuron has a potential to negatively affect hawthorn (Crataegus monogyna) hedgerows near agricultural fields. For this purpose four doses of metsulfuron ranging from 5% to 40% of the field dose (4 g metsulfuron per hectare) were sprayed on trees in seven different hawthorn hedgerows. The actual deposition on the leaves was measured by means of a tracer (glycine). Spraying was conducted both at the bud stage and at early flowering. Leaves, flowers, green berries and mature berries were harvested and the number and weight of each were measured. The spraying at the bud stage caused a highly significant reduction in number and dry weight of berries, whereas it had no effects on leaf and flower production. The berry reduction was close to 100% at actual depositions relevant for spray drift under normal conditions. Spraying at early flowering also significantly reduced berries although the effect was smaller than for the spraying at bud stage. The early flower stage spraying caused no reduction in number and size of leaves. The possible ecological consequence is that metsulfuron spray drift from agricultural fields has a potential to reduce the amount of berries available for frugivorous birds in nearby hedgerows. A potential need for regulatory measures to reduce herbicide spray drift to hedgerows situated near agricultural fields with herbicide use is also indicated.

  14. Assessing the genotoxic potential of chlorothalonil drift from potato fields in Prince Edward Island, Canada.

    PubMed

    Garron, Christine; Knopper, Loren D; Ernst, William R; Mineau, Pierre

    2012-02-01

    Chlorothalonil, a broad-spectrum nonsystemic foliar fungicide, is one of the most extensively used pesticide active ingredients on Prince Edward Island, Canada, for blight control on potatoes. In ambient air-sampling programs conducted in 1998 and 1999 and from 2002 to 2004, chlorothalonil was measured in 97% of air samples collected. It is known to produce severe eye and skin irritation, is cytogenic and is considered a possible human carcinogen by the United States Environmental Protection Agency and the International Agency for Research on Cancer. Inhalation studies that quantify chlorothalonil subchronic effects (e.g., genotoxicity) are lacking. The purpose of this study was to assess the possible genotoxic potential of chlorothalonil under field conditions by using the alkaline comet assay to assess DNA damage in CD-1 mice. Mice were selected as a surrogate species for wild small mammals (e.g., meadow voles, deer mice) known to inhabit areas adjacent to potato fields. Mice were placed at three locations downwind of a chlorothalonil application (0, 30, and 100 m) and at one up-wind control location at least 30 m from the field. Downwind mice were exposed to drift throughout the spray period (approximately 30 min) and for an additional hour after spraying. Air samples were collected during the spray trials (before, during, and after spraying) using high-volume polyurethane foam and PM(2.5) air samplers. Pesticide deposits were measured using 20 × 25 cm glass-fibre filters. After exposure, blood was collected from each mouse, and DNA strand breaks in white blood cells measured using comet assay. Results suggest that metrics of DNA damage [tail length (TL), percent DNA in tail] were not significantly related to total air chlorothalonil concentration from the three spray trials (r (2) = 0.000, P = 0.907 for TL; r (2) = 0.001, P = 0.874 for percent DNA). In addition, no significant difference in DNA damage was observed between exposed (at 0 m) and control animals (P = 0.357 for TL; P = 0.958 for percent DNA). Based on these results it can be concluded that wild small mammals living beside fields sprayed with chlorothalonil are at no greater risk of exposure-related DNA damage than conspecifics from unexposed areas.

  15. Effect of particle in-flight behavior on the composition of thermal barrier coatings

    NASA Astrophysics Data System (ADS)

    Zhao, L.; Bai, Y.; Tang, J. J.; Liu, K.; Ding, C. H.; Yang, J. F.; Han, Z. H.

    2013-12-01

    In this work, 6 to 11 mol% YO1.5-stabilized zirconia (YSZ) coatings were deposited by supersonic and conventional atmospheric plasma spraying. During spraying, the surface temperature and velocity of in-flight particles were monitored by Spray Watch 2i on-line system. The phase composition of as-sprayed coatings was analyzed by X-ray diffractometry (XRD). Lattice parameters, tetragonality and the content of YO1.5 (mol%) of as-sprayed coatings were calculated according to the position of (0 0 4) and (4 0 0) diffraction peaks. It was found that the as-sprayed coatings were composed of metastable non-transformable tetragonal phase (t‧). However, the amount of YO1.5 (mol%) in the as-sprayed coatings decreased with the increase of melting index of in-flight particles due to the partial evaporation of YO1.5 during spraying.

  16. Thermal spray for commercial shipbuilding

    NASA Astrophysics Data System (ADS)

    Rogers, F. S.

    1997-09-01

    Thermal spraying of steel with aluminum to protect it from corrosion is a technology that has been proven to work in the marine environment. The thermal spray coating system includes a paint sealer that is applied over the thermally sprayed aluminum. This extends the service life of the coating and provides color to the end product. The thermal spray system protects steel both through the principle of isolation (as in painting) and galvanizing. With this dual protection mechanism, steel is protected from corrosion even when the coating is damaged. The thermal- sprayed aluminum coating system has proved the most cost- effective corrosion protection system for the marine environment. Until recently, however, the initial cost of application has limited its use for general application. Arc spray technology has reduced the application cost of thermal spraying of aluminum to below that of painting. Commercial shipbuilders could use this technology to enhance their market position in the marine industry.

  17. Automatic macroscopic characterization of diesel sprays by means of a new image processing algorithm

    NASA Astrophysics Data System (ADS)

    Rubio-Gómez, Guillermo; Martínez-Martínez, S.; Rua-Mojica, Luis F.; Gómez-Gordo, Pablo; de la Garza, Oscar A.

    2018-05-01

    A novel algorithm is proposed for the automatic segmentation of diesel spray images and the calculation of their macroscopic parameters. The algorithm automatically detects each spray present in an image, and therefore it is able to work with diesel injectors with a different number of nozzle holes without any modification. The main characteristic of the algorithm is that it splits each spray into three different regions and then segments each one with an individually calculated binarization threshold. Each threshold level is calculated from the analysis of a representative luminosity profile of each region. This approach makes it robust to irregular light distribution along a single spray and between different sprays of an image. Once the sprays are segmented, the macroscopic parameters of each one are calculated. The algorithm is tested with two sets of diesel spray images taken under normal and irregular illumination setups.

  18. Electrical Resistivity of Wire Arc Sprayed Zn and Cu Coatings for In-Mold-Metal-Spraying

    NASA Astrophysics Data System (ADS)

    Bobzin, K.; Öte, M.; Knoch, M. A.; Liao, X.; Hopmann, Ch; Ochotta, P.

    2018-06-01

    Electrical functionalities can be integrated into plastic parts by integrating thermally sprayed metal coatings into the non-conductive base material. Thermally sprayed conducting tracks for power and signal transmission are one example. In this case, the electrical resistance or resistivity of the coatings should be investigated. Therefore, the electrical resistivity of wire arc sprayed Zn and Cu coatings has been investigated. In case of Zn coatings, spray distance, gas pressure and wire diameter could be identified as significant influencing parameters on the electrical resistivity. In contrast, process gas, gas pressure and voltage do have a significant influence on the electrical resistivity of Cu coatings. Through the use of the In-Mold-Metal-Spraying method (IMMS), thermal degradation can be avoided by transferring thermally sprayed coating from a mold insert onto the plastic part. Therefore, the influence of the transfer process on the electrical resistance of the coatings has also been investigated.

  19. The Cold Gas-Dynamic Spray and Characterization of Microcrystalline and Nanocrystalline Copper Alloys

    DTIC Science & Technology

    2012-12-01

    cold gas-dynamic spray process are well understood, the effects of feedstock powder microstructure and composition on the deposition process remain...The Relationship between Powder Zinc Content and Porosity .....74  5.  Compositional Variability as a Side Effect of the Cold Spray Deposition Process ...to expect in cold spray deposited copper coatings based on common spray parameters. Ning et

  20. 46 CFR 35.40-18 - Water spray systems-TB/ALL.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 1 2014-10-01 2014-10-01 false Water spray systems-TB/ALL. 35.40-18 Section 35.40-18 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY TANK VESSELS OPERATIONS Posting and Marking Requirements-TB/ALL § 35.40-18 Water spray systems—TB/ALL. (a) Water spray system apparatus shall be marked: “WATER SPRAY SYSTEM,” as appropriate, in not...

  1. 46 CFR 35.40-18 - Water spray systems-TB/ALL.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 1 2013-10-01 2013-10-01 false Water spray systems-TB/ALL. 35.40-18 Section 35.40-18 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY TANK VESSELS OPERATIONS Posting and Marking Requirements-TB/ALL § 35.40-18 Water spray systems—TB/ALL. (a) Water spray system apparatus shall be marked: “WATER SPRAY SYSTEM,” as appropriate, in not...

  2. Effectiveness of a Reduced-Risk Insecticide Based Bed Bug Management Program in Low-Income Housing.

    PubMed

    Singh, Narinderpal; Wang, Changlu; Cooper, Richard

    2013-11-28

    Bed bug (Cimex lectularius L.) infestations are becoming increasingly common in low-income communities. Once they are introduced, elimination is very difficult. As part of the efforts to develop effective and safe bed bug management programs, we conducted a laboratory study evaluating the efficacy of a reduced-risk insecticide-Alpine aerosol (0.5% dinotefuran). We then conducted a field evaluation of a reduced-risk insecticide based integrated pest management (IPM) program in low-income family apartments with young children. In laboratory evaluations, direct spray and 5 min exposure to dry Alpine aerosol residue caused 100.0 ± 0.0 and 91.7 ± 8.3% mortality to bed bug nymphs, respectively. Direct Alpine aerosol spray killed 91.3 ± 4.3% of the eggs. The IPM program included education, steam, bagging infested linens, placing intercepting devices under furniture legs and corners of rooms, applying Alpine aerosol and Alpine dust (0.25% dinotefuran, 95% diatomaceous earth dust), and regularly scheduled monitoring and re-treatment. Nine apartments ranging from 1-1,428 (median: 29) bed bugs based on visual inspection and Climbup interceptor counts were included. Over a 6-month period, an average 172 g insecticide (Alpine aerosol + Alpine dust) was used in each apartment, a 96% reduction in pesticide usage compared to chemical only treatment reported in a similar environment. The IPM program resulted in an average of 96.8 ± 2.2% reduction in the number of bed bugs. However, elimination of bed bugs was only achieved in three lightly infested apartments (<30 bed bugs at the beginning). Elimination success was closely correlated with the level of bed bug populations.

  3. Norplant campaign in India.

    PubMed

    1992-01-01

    The Indian government's plan to introduce the new long-acting contraceptive Norplant in the National Family Planning Program under pressure from the US government is opposed because Norplant has not been adequately tested. The government has reduced the funding for the national program for eradication of malaria and tuberculosis, but it is proposing to finance a Norplant based population project for the State of Uttar Pradesh. The powers that can turn a deaf ear to the possible hazards of Norplant. Implanted in the arm of a woman, the chemical is released into the bloodstream providing contraception for 5 years. Severe adverse reactions include depression, heart disease thromboembolism, high blood pressure, and ovarian cysts. Many such long-acting contraceptives are being developed including injectables, vaccines, nasal sprays, and vaginal rings with potential permanent impairment to fertility. One of the major objectives of the Family Planning Program is the improvement of the health status of women, but the introduction of Norplant would harm healthy young women. Therefore, the group Saheli and others in the campaign demand: 1) that plans for introduction of Norplant in the Family Planning Program be halted immediately; 2) that the introduction of any other long acting invasive contraceptive such as Net-En, vaginal ring, nasal spray, and anti-fertility vaccine be banned, both on the grounds of inadequacy of the health services and loss of user controls; 3) that information on the safety aspects of Norplant and the basis on which the Drugs Controller has granted his approval be made public; 4) that each and every one of the hundreds of women who still have the implant should be located, and the implant removed; and 5) that all hormonal contraceptive preparations be banned in the social marketing program as their use involves extensive monitoring.

  4. Effectiveness of a Reduced-Risk Insecticide Based Bed Bug Management Program in Low-Income Housing

    PubMed Central

    Singh, Narinderpal; Wang, Changlu; Cooper, Richard

    2013-01-01

    Bed bug (Cimex lectularius L.) infestations are becoming increasingly common in low-income communities. Once they are introduced, elimination is very difficult. As part of the efforts to develop effective and safe bed bug management programs, we conducted a laboratory study evaluating the efficacy of a reduced-risk insecticide—Alpine aerosol (0.5% dinotefuran). We then conducted a field evaluation of a reduced-risk insecticide based integrated pest management (IPM) program in low-income family apartments with young children. In laboratory evaluations, direct spray and 5 min exposure to dry Alpine aerosol residue caused 100.0 ± 0.0 and 91.7 ± 8.3% mortality to bed bug nymphs, respectively. Direct Alpine aerosol spray killed 91.3 ± 4.3% of the eggs. The IPM program included education, steam, bagging infested linens, placing intercepting devices under furniture legs and corners of rooms, applying Alpine aerosol and Alpine dust (0.25% dinotefuran, 95% diatomaceous earth dust), and regularly scheduled monitoring and re-treatment. Nine apartments ranging from 1–1,428 (median: 29) bed bugs based on visual inspection and Climbup interceptor counts were included. Over a 6-month period, an average 172 g insecticide (Alpine aerosol + Alpine dust) was used in each apartment, a 96% reduction in pesticide usage compared to chemical only treatment reported in a similar environment. The IPM program resulted in an average of 96.8 ± 2.2% reduction in the number of bed bugs. However, elimination of bed bugs was only achieved in three lightly infested apartments (<30 bed bugs at the beginning). Elimination success was closely correlated with the level of bed bug populations. PMID:26462533

  5. Physicochemical and in vitro deposition properties of salbutamol sulphate/ipratropium bromide and salbutamol sulphate/excipient spray dried mixtures for use in dry powder inhalers.

    PubMed

    Corrigan, Deirdre O; Corrigan, Owen I; Healy, Anne Marie

    2006-09-28

    The physicochemical and aerodynamic properties of spray dried powders of the drug/drug mixture salbutamol sulphate/ipratropium bromide were investigated. The in vitro deposition properties of spray dried salbutamol sulphate and the spray dried drug/excipient mixtures salbutamol sulphate/lactose and salbutamol sulphate/PEG were also determined. Spray drying ipratropium bromide monohydrate resulted in a crystalline material from both aqueous and ethanolic solution. The product spray dried from aqueous solution consisted mainly of ipratropium bromide anhydrous. There was evidence of the presence of another polymorphic form of ipratropium bromide. When spray dried from ethanolic solution the physicochemical characterisation suggested the presence of an ipratropium bromide solvate with some anhydrous ipratropium bromide. Co-spray drying salbutamol sulphate with ipratropium bromide resulted in amorphous composites, regardless of solvent used. Particles were spherical and of a size suitable for inhalation. Twin impinger studies showed an increase in the fine particle fraction (FPF) of spray dried salbutamol sulphate compared to micronised salbutamol sulphate. Co-spray dried salbutamol sulphate:ipratropium bromide 10:1 and 5:1 systems also showed an increase in FPF compared to micronised salbutamol sulphate. Most co-spray dried salbutamol sulphate/excipient systems investigated demonstrated FPFs greater than that of micronised drug alone. The exceptions to this were systems containing PEG 4000 20% or PEG 20,000 40% both of which had FPFs not significantly different from micronised salbutamol sulphate. These two systems were crystalline unlike most of the other spray dried composites examined which were amorphous in nature.

  6. Thermal sprayed composite melt containment tubular component and method of making same

    DOEpatents

    Besser, Matthew F.; Terpstra, Robert L.; Sordelet, Daniel J.; Anderson, Iver E.

    2002-03-19

    A tubular thermal sprayed melt containment component for transient containment of molten metal or alloy wherein the tubular member includes a thermal sprayed inner melt-contacting layer for contacting molten metal or alloy to be processed, a thermal sprayed heat-generating layer deposited on the inner layer, and an optional thermal sprayed outer thermal insulating layer. The thermal sprayed heat-generating layer is inductively heated as a susceptor of an induction field or electrical resistively heated by passing electrical current therethrough. The tubular thermal sprayed melt containment component can comprise an elongated melt pour tube of a gas atomization apparatus where the melt pour tube supplies molten material from a crucible to an underlying melt atomization nozzle.

  7. Development of improved high temperature coatings for IN-792 + HF

    NASA Technical Reports Server (NTRS)

    Profant, D. D.; Naik, S. K.

    1981-01-01

    The development for t-55 l712 engine of high temperature for integral turbine nozzles with improved thermal fatigue resistance without sacrificing oxidation/corrosion protection is discussed. The program evaluated to coating systems which comprised one baseline plasma spray coating (12% Al-NiCoCrALY), three aluminide coatings including the baseline aluminide (701), two CoNiCrAly (6% Al) + aluminide systems and four NiCoCrY + aluminide coating were evaluated. The two-step coating processes were investigated since it offered the advantage of tailoring the composition as well as properly coating surfaces of an integral or segmented nozzle. Cyclic burner rig thermal fatigue and oxidation/corrosion tests were used to evaluate the candidate coating systems. The plasma sprayed 12% Al-NiCoCrAlY was rated the best coating in thermal fatigue resistance and outperformed all coatings by a factor between 1.4 to 2.5 in cycles to crack initiation. However, this coatings is not applicable to integral or segmented nozzles due to the line of sight limitation of the plasma spray process. The 6% Al-CoNiCrAlY + Mod. 701 aluminide (32 w/o Al) was rated the best coating in oxidation/corrosion resistance and was rated the second best in thermal fatigue resistance.

  8. Fabrication of topical metered dose film forming sprays for pain management.

    PubMed

    Ranade, Sneha; Bajaj, Amrita; Londhe, Vaishali; Babul, Najib; Kao, Danny

    2017-03-30

    Topical film-forming metered dose spray formulations were designed for management of pain. Ropivacaine, a local anesthetic is explored for its topical efficacy in alleviating pain. Metered dose spray containers, organic solvents, film forming polymers and permeation enhancers were utilized to fabricate the Metered Dose topical spray. Factors like viscosity, spray pattern, spray angle, volume of actuation, droplet size distribution of the metered dose spray formulation and drying time, flexibility and wash-ability of the film formed after spraying were assessed. Permeation of the drug into the porcine skin was observed based on ex-vivo diffusion studies and confocal microscopy. The results indicated a high level of drug concentration in the skin layers. Anti-nociceptive efficacy of the formulations was assessed on Wistar rats by hot plate and tail flick tests, based on the response to pain perception. The results were comparable to the conventional lidocaine gel. Topical film forming sprays have the ability to provide an accurate, long lasting and patient compliant delivery of drugs on the skin as compared to conventional gels. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Sequential cryogen spraying for heat flux control at the skin surface

    NASA Astrophysics Data System (ADS)

    Majaron, Boris; Aguilar, Guillermo; Basinger, Brooke; Randeberg, Lise L.; Svaasand, Lars O.; Lavernia, Enrique J.; Nelson, J. Stuart

    2001-05-01

    Heat transfer rate at the skin-air interface is of critical importance for the benefits of cryogen spray cooling in combination with laser therapy of shallow subsurface skin lesions, such as port-wine stain birthmarks. With some cryogen spray devices, a layer of liquid cryogen builds up on the skin surface during the spurt, which may impair heat transfer across the skin surface due to relatively low thermal conductivity and potentially higher temperature of the liquid cryogen layer as compared to the spray droplets. While the mass flux of cryogen delivery can be adjusted by varying the atomizing nozzle geometry, this may strongly affect other spray properties, such as lateral spread (cone), droplet size, velocity, and temperature distribution. We present here first experiments with sequential cryogen spraying, which may enable accurate mass flux control through variation of spray duty cycle, while minimally affecting other spray characteristics. The observed increase of cooling rate and efficiency at moderate duty cycle levels supports the above described hypothesis of isolating liquid layer, and demonstrates a novel approach to optimization of cryogen spray devices for individual laser dermatological applications.

  10. Granulometric characterization of airborne particulate release during spray application of nanoparticle-doped coatings

    NASA Astrophysics Data System (ADS)

    Göhler, Daniel; Stintz, Michael

    2014-08-01

    Airborne particle release during the spray application of coatings was analyzed in the nanometre and micrometre size range. In order to represent realistic conditions of domestic and handcraft use, the spray application was performed using two types of commercial propellant spray cans and a manual gravity spray gun. Four different types of coatings doped with three kinds of metal-oxide tracer nanoparticle additives (TNPA) were analyzed. Depending on the used coating and the kind of spray unit, particulate release numbers between 5 × 108 and 3 × 1010 particles per gram ejection mass were determined in the dried spray aerosols. The nanoparticulate fraction amounted values between 10 and 60 no%. The comparison between nanoparticle-doped coatings with non-doped ones showed no TNPA-attributed differences in both the macroscopic spray process characteristics and the particle release numbers. SEM, TEM and EDX-analyzes showed that the spray aerosols were composed of particles made up solely from matrix material and sheathed pigments, fillers and TNPAs. Isolated ZnO- or Fe2O3-TNPAs could not be observed.

  11. Aerial electrostatic spray deposition and canopy penetration in cotton

    USDA-ARS?s Scientific Manuscript database

    Spray deposition on abaxial and adaxial leaf surfaces along with canopy penetration are essential for insect control and foliage defoliation in cotton production agriculture. Researchers have reported that electrostatically charged sprays have increased spray deposit onto these surfaces under widel...

  12. The Development of an Environmentally Compliant, Multi-Functional Aerospace Coating Using Molecular- and Nano-Engineering Methods

    DTIC Science & Technology

    2006-10-02

    Al -TM-RE) alloy which could by spray applied using various deposition routes or deposited as a powder that is...corrosion properties of various spray deposited alloys from their properties as defective coatings on 2024-T3. "* HVOF spray deposited and cold spray ...layer. "* A method has been developed to distinguish the intrinsic corrosion properties of various spray deposited

  13. Deodorant spray: a newly identified cause of cold burn.

    PubMed

    May, Ulrich; Stirner, Karl-Heinz; Lauener, Roger; Ring, Johannes; Möhrenschlager, Matthias

    2010-09-01

    Two patients encountered a first-degree cold burn after use of a deodorant spray. The spray-nozzle to skin-surface distance was approximately 5 cm, and the spraying lasted approximately 15 seconds. Under laboratory conditions, the deodorant in use was able to induce a decline in temperature of >60 degrees C. These 2 cases highlight a little-known potential for skin damage by deodorant sprays if used improperly.

  14. Effect of formulation- and administration-related variables on deposition pattern of nasal spray pumps evaluated using a nasal cast.

    PubMed

    Kundoor, Vipra; Dalby, Richard N

    2011-08-01

    To systematically evaluate the effect of formulation- and administration-related variables on nasal spray deposition using a nasal cast. Deposition pattern was assessed by uniformly coating a transparent nose model with Sar-Gel®, which changes from white to purple on contact with water. Sprays were subsequently discharged into the cast, which was then digitally photographed. Images were quantified using Adobe® Photoshop. The effects of formulation viscosity (which influences droplet size), simulated administration techniques (head orientation, spray administration angle, spray nozzle insertion depth), spray pump design and metering volume on nasal deposition pattern were investigated. There was a significant decrease in the deposition area associated with sprays of increasing viscosity. This appeared to be mediated by an increase in droplet size and a narrowing of the spray plume. Administration techniques and nasal spray pump design also had a significant effect on the deposition pattern. This simple color-based method provides quantitative estimates of the effects that different formulation and administration variables may have on the nasal deposition area, and provides a rational basis on which manufacturers of nasal sprays can base their patient instructions or post approval changes when it is impractical to optimize these using a clinical study.

  15. Comparision on dynamic behavior of diesel spray and rapeseed oil spray in diesel engine

    NASA Astrophysics Data System (ADS)

    Sapit, Azwan; Azahari Razali, Mohd; Faisal Hushim, Mohd; Jaat, Norrizam; Nizam Mohammad, Akmal; Khalid, Amir

    2017-04-01

    Fuel-air mixing is important process in diesel combustion. It significantly affects the combustion and emission of diesel engine. Biomass fuel has high viscosity and high distillation temperature and may negatively affect the fuel-air mixing process. Thus, study on the spray development and atomization of this type of fuel is important. This study investigates the atomization characteristics and droplet dynamic behaviors of diesel engine spray fuelled by rapeseed oil (RO) and comparison to diesel fuel (GO). Optical observation of RO spray was carried out using shadowgraph photography technique. Single nano-spark photography technique was used to study the characteristics of the spray while dual nano-spark shadowgraph technique was used to study the spray droplet behavior. Using in-house image processing algorithm, the images were processed and the boundary condition of each spray was also studied. The results show that RO has very poor atomization due to the high viscosity nature of the fuel when compared to GO. This is in agreement with the results from spray droplet dynamic behavior studies that shows due to the high viscosity, the RO spray droplets are large in size and travel downward, with very little influence of entrainment effect due to its large kinematic energy.

  16. Dynamic characteristics of pulsed supersonic fuel sprays

    NASA Astrophysics Data System (ADS)

    Pianthong, K.; Matthujak, A.; Takayama, K.; Milton, B. E.; Behnia, M.

    2008-06-01

    This paper describes the dynamic characteristics of pulsed, supersonic liquid fuel sprays or jets injected into ambient air. Simple, single hole nozzles were employed with the nozzle sac geometries being varied. Different fuel types, diesel fuel, bio-diesel, kerosene, and gasoline were used to determine the effects of fuel properties on the spray characteristics. A vertical two-stage light gas gun was employed as a projectile launcher to provide a high velocity impact to produce the liquid jet. The injection pressure was around 0.88-1.24 GPa in all cases. The pulsed, supersonic fuel sprays were visualized by using a high-speed video camera and shadowgraph method. The spray tip penetration and velocity attenuation and other characteristics were examined and are described here. An instantaneous spray tip velocity of 1,542 m/s (Mach number 4.52) was obtained. However, this spray tip velocity can be sustained for only a very short period (a few microseconds). It then attenuates very quickly. The phenomenon of multiple high frequency spray pulses generated by a single shot impact and the changed in the angle of the shock structure during the spray flight, which had already been observed in previous studies, is again noted. Multiple shock waves from the conical nozzle spray were also clearly captured.

  17. A new HF-resistant tandem spray chamber for improved determination of trace elements and Pb isotopes using inductively coupled plasma-mass spectrometry

    NASA Astrophysics Data System (ADS)

    Krachler, Michael; Rausch, Nicole; Feuerbacher, Helmut; Klemens, Patrick

    2005-07-01

    The use of a new HF-resistant tandem spray chamber arrangement consisting of a cyclonic spray chamber and a Scott-type spray chamber made from PFA and PEEK provides a straightforward approach for improving the performance of inductively coupled-mass spectrometry (ICP-MS). The characteristics of the tandem spray chamber were critically evaluated against a PEEK cyclonic and a PFA Scott-type spray chamber, respectively. Sensitivity across the entire mass range was increased by about three times compared to the conventional setup utilizing only one spray chamber. Precision of the results, especially at low signal intensities, improved by 160% and 31% compared to the cyclonic and Scott-type spray chamber, respectively. Using the tandem spray chamber, the oxide formation rate was lowered by about 50%. Signals as low as 30 counts could be determined under routine measurement conditions with a RSD of 2.4% thus allowing to precisely quantify small concentration differences at the ng l - 1 concentration level. The excellent precision (0.02-0.07%) of 206Pb / 207Pb and 206Pb / 208Pb ratios determined in pore water samples was rather limited by the instrumental capabilities of the single collector ICP-MS instrument than by the performance of the tandem spray chamber.

  18. A network meta-analysis provides new insight into fungicide scheduling for the control of Botrytis cinerea in vineyards.

    PubMed

    González-Domínguez, Elisa; Fedele, Giorgia; Caffi, Tito; Delière, Laurent; Sauris, Pierre; Gramaje, David; Ramos-Sáez de Ojer, José Luis; Díaz-Losada, Emilia; Díez-Navajas, Ana M; Bengoa, Paul; Rossi, Vittorio

    2018-06-09

    Control of Botrytis bunch rot (BBR) is currently based on the application of fungicides at four timings corresponding to specific growth stages of vines: end of flowering (A), pre-bunch closure (B), veraison (C) and before harvest (D). The current research provides a network meta-analysis of 116 studies conducted between 1963 and 2016 in nine countries, in which 14 strategies (based on combinations of 1, 2, 3, or 4 sprays applied in A, B, C, and/or D) were compared. When a 1-spray strategy was applied, BBR control was more effective with sprays applied in A, C, or D than B. With a 2-spray strategy, strategy AC provided similar control as strategy BC; strategy CD also provided good control. For a 3-spray strategy, the best disease control was consistently obtained with strategy ACD. Four sprays strategy ABCD provided the best control but often involved needless sprays so that the routine application of four sprays is not justified. Spraying at timing A seems to be very important for achieving efficient and flexible disease control. Flexibility is reduced by spraying at timing B rather than A. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  19. Determining the drift potential of Venturi nozzles compared with standard nozzles across three insecticide spray solutions in a wind tunnel.

    PubMed

    Ferguson, J Connor; Chechetto, Rodolfo G; O'Donnell, Chris C; Dorr, Gary J; Moore, John H; Baker, Greg J; Powis, Kevin J; Hewitt, Andrew J

    2016-08-01

    Previous research has sought to adopt the use of drift-reducing technologies (DRTs) for use in field trials to control diamondback moth (DBM) Plutella xylostella (L.) (Lepidoptera: Plutellidae) in canola (Brassica napus L.). Previous studies observed no difference in canopy penetration from fine to coarse sprays, but the coverage was higher for fine sprays. DBM has a strong propensity to avoid sprayed plant material, putting further pressure on selecting technologies that maximise coverage, but often this is at the expense of a greater drift potential. This study aims to examine the addition of a DRT oil that is labelled for control of DBM as well and its effect on the drift potential of the spray solution. The objectives of the study are to quantify the droplet size spectrum and spray drift potential of each nozzle type to select technologies that reduce spray drift, to examine the effect of the insecticide tank mix at both (50 and 100 L ha(-1) ) application rates on droplet size and spray drift potential across tested nozzle type and to compare the droplet size results of each nozzle by tank mix against the drift potential of each nozzle. The nozzle type affected the drift potential the most, but the spray solution also affected drift potential. The fine spray quality (TCP) resulted in the greatest drift potential (7.2%), whereas the coarse spray quality (AIXR) resulted in the lowest (1.3%), across all spray solutions. The spray solutions mixed at the 100 L ha(-1) application volume rate resulted in a higher drift potential than the same products mixed at the 50 L ha(-1) mix rate. The addition of the paraffinic DRT oil was significant in reducing the drift potential of Bacillus thuringiensis var. kurstkai (Bt)-only treatments across all tested nozzle types. The reduction in drift potential from the fine spray quality to the coarse spray quality was up to 85%. The addition of a DRT oil is an effective way to reduce the spray solution drift potential across all nozzle types and tank mixes evaluated in this study. The greatest reduction in drift potential can be achieved by changing nozzle type, which can reduce the losses of the spray to the surrounding environment. Venturi nozzles greatly reduce the drift potential compared with standard nozzles by as much as 85% across all three insecticide spray solutions. Results suggest that a significant reduction in drift potential can be achieved by changing the nozzle type, and can be achieved without a loss in control of DBM. © 2016 Society of Chemical Industry. © 2016 Society of Chemical Industry.

  20. 44 CFR 16.150 - Program accessibility: Existing facilities.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 44 Emergency Management and Assistance 1 2010-10-01 2010-10-01 false Program accessibility: Existing facilities. 16.150 Section 16.150 Emergency Management and Assistance FEDERAL EMERGENCY MANAGEMENT... IN PROGRAMS OR ACTIVITIES CONDUCTED BY THE FEDERAL EMERGENCY MANAGEMENT AGENCY § 16.150 Program...

  1. 78 FR 19136 - Emergency Relief Program

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-29

    ... implementation of the Federal Transit Administration's (FTA) Public Transportation Emergency Relief Program under...-21, Pub. L. 112-141) authorized the Public Transportation Emergency Relief Program at 49 U.S.C. 5324. The Emergency Relief Program allows FTA to make grants for eligible public transportation capital and...

  2. A hypothesis of the Effect of a New Nasal Spray Made from Natural Medicines on Allergic Rhinitis in Animals

    NASA Astrophysics Data System (ADS)

    Zhai, Hailong; Wang, Yufang

    2018-01-01

    To verify the effect of a new nasal spray made from natural medicines on allergic rhinitis in animals. Methods: The main natural medicines contained in Acusine nasal spray plus essential traditional Chinese medicine contained in drugs for allergic rhinitis in Chinese market were used. By preparation process of extraction of traditional Chinese medicine such as steam distillation, ethanol extraction, a new nasal spray made from natural medicines was prepared. In the meantime, 24 BALB/c mice and New Zealand white rabbits were used. Then, mice were randomly divided into four group; control group, beclomethasone dipropionate group, Acusine group and new spray group, 6 mice in each group. Moreover, the effect of the new nasal spray made on passive cutaneous anaphylaxis was conducted by detecting absorptions of Evan’s blue (620nm) in the four groups. Allergic rhinitis models in 40 New Zealand white rabbits were established. Consequently, 40 allergic rhinitis models in rabbits were randomly divided into control group, Acusine group and new spray group, 10 rabbits in each group. The four groups were sprayed nasally with saline, Acusine spray and new spray respectively, three times/d, for 30 days. The nasal resistances in the four groups were measured with a rhinoresistometer. Moreover, their nasal mucosa was taken for HE staining. Consequently, their pathological manifestations were observed. The results: Absorption of Evan’s blue (620nm) of new spray group will be found significantly lower than Acusine group (P<0.05) and will have no significantly difference compared with beclomethasone dipropionate group(P>0.05). On the other hand, absorption of Evan’s blue (620nm) of beclomethasone dipropionate group will be significantly lower than Acusine group (P<0.05). Moreover, The nasal resistances of new spray group will be significantly lower than Acusine group (P<0.05) and will have no significantly difference compared with beclomethasone dipropionate group (P».05). Moreover, the nasal resistances of beclomethasone dipropionate group will be significantly lower than Acusine group (P<0.05). While, the nasal mucosa of control group will be found typical as nasal mucosa of allergic rhinitis. However, the nasal mucosa of beclomethasone dipropionate group, Acusine group and new spray group will be better than control group. Of them, new spray group will be the best. The nasal mucosa of beclomethasone dipropionate group will show the manifestation of drug-induced rhinitis. The conclusion: The invented new spray will not only have a better treatment effect on allergic rhinitis, similar with beclomethasone dipropionate, than Acusine Nasal Spray but also will not leave side effect on nasal mucosa, compared with beclomethasone dipropionate. Thus, the new spray made from natural medicines can be further studied as a better prescription drug, rather than an OTC like Acusine Nasal Spray, to replace beclomethasone dipropionate nasal spray. However, further study that would be required to produce a more meaningful answer.

  3. Stress corrosion evaluation of HP 9Ni-4Co-0.20C steel

    NASA Technical Reports Server (NTRS)

    Torres, Pablo D.

    1993-01-01

    A stress corrosion cracking (SCC) evaluation was undertaken on HP 9Ni-4Co-0.20C steel in support of the Advanced Solid Rocket Motor (ASRM) program. This alloy was tested in plate, bar, and ring forging forms. Several heat treating procedures yielded ultimate tensile strengths ranging from 1,407 to 1,489 MPa (204 to 216 ksi). The test environments were high humidity, alternate immersion in 3.5-percent NaCl, and 5-percent salt spray. Stress levels ranged from 25 to 90 percent of the yield strengths. The majority of the tests were conducted for 90 days. Even though the specimens rusted significantly in salt spray and alternate immersion, no failures occurred. Therefore, it can be concluded that this alloy, in the forms and at the strength levels tested, is highly resistant to SCC in salt and high humidity environments.

  4. Stability analysis of direct contact heat exchangers subject to system perturbations. Final report, Task 2

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jacobs, H.R.

    1985-01-01

    This report includes a project summary, copies of two papers resulting from the work and the Ph.D. Dissertation of Dr. Mehdi Golafshani entitled, ''Stability of a Direct Contact Heat Exchanger''. Specifically, the work deals with the operational stability of a spray column type heat exchanger subject to disturbances typical of those which can occur for geothermal applications. A computer program was developed to solve the one-dimensional transient two-phase flow problem and it was applied to the design of a spray column. The operation and design of the East Mesa 500kW/sub e/ direct contactor was assessed. It is shown that themore » heat transfer is governed by the internal resistance of the dispersed phase. In fact, the performance is well-represented by diffusion of heat within the drops. 5 refs.« less

  5. Tank Tests of 1/5.5-Scale Forward Dynamic Model of the Columbia XJL-1 Amphibian - Langley Tank Model 208, TED No. NACA 2336

    NASA Technical Reports Server (NTRS)

    Havens, Robert F.

    1946-01-01

    Tests of a powered dynamic model of the Columbia XJL-1 amphibian were made in Langley tank no.1 to determine the hydrodynamic stability and spray characteristics of the basic hull and to investigate the effects of modifications on these characteristics. Modifications to the forebody chime flare, the step, and the afterbody, and an increase in the angle of incidence of the wing were included in the test program. The seaworthiness and spray characteristics were studied from simulated taxi runs in smooth and rough water. The trim limits of stability, the range of stable positions of the enter of gravity for take-off, and the landing stability were determined in smooth water. The aerodynamic lift, pitching moment, and thrust were determined at speeds up to take-off speed.

  6. Pulpwood, pesticides, and people. Controlling spruce budworm in northeastern North America

    NASA Astrophysics Data System (ADS)

    Irland, Lloyd C.

    1980-09-01

    The eastern spruce budworm is a major forest pest over the continental range of the spruce-fir forest ecosystem and its southern ecotonal fringes in Canada and the northeastern United States. The current budworm outbreak illustrates the difficulty of arriving at economically sound and publicly acceptable forest pest control policies. Policies ranging from no use of chemical control to annual widespread crop protection have been adopted. There is no single all-around “best” policy for spruce budworm control. Chemical spray programs have demonstrably slowed the normal progress of mortality due to budworm, but have not eradicated the pest. Where industry remains heavily dependent on a fully utilized spruce-fir forest, no easy, low-cost solutions to the budworm problem exist. Reliance on spraying will have to be reduced and plans made to utilize higher levels of tree mortality and to manage the forest for lower future vulnerability.

  7. Comparative field trial of alternative vector control strategies for non-domiciliated Triatoma dimidiata.

    PubMed

    Ferral, Jhibran; Chavez-Nuñez, Leysi; Euan-Garcia, Maria; Ramirez-Sierra, Maria Jesus; Najera-Vazquez, M Rosario; Dumonteil, Eric

    2010-01-01

    Chagas disease is a major vector-borne disease, and regional initiatives based on insecticide spraying have successfully controlled domiciliated vectors in many regions. Non-domiciliated vectors remain responsible for a significant transmission risk, and their control is a challenge. We performed a proof-of-concept field trial to test alternative strategies in rural Yucatan, Mexico. Follow-up of house infestation for two seasons following the interventions confirmed that insecticide spraying should be performed annually for the effective control of Triatoma dimidiata; however, it also confirmed that insect screens or long-lasting impregnated curtains may represent good alternative strategies for the sustained control of these vectors. Ecosystemic peridomicile management would be an excellent complementary strategy to improve the cost-effectiveness of interventions. Because these strategies would also be effective against other vector-borne diseases, such as malaria or dengue, they could be integrated within a multi-disease control program.

  8. Health risk behaviors associated with agrochemical exposure among rice farmers in a rural community, Thailand: a community-based ethnography.

    PubMed

    Raksanam, Buppha; Taneepanichskul, Surasak; Robson, Mark G; Siriwong, Wattasit

    2014-11-01

    The study objective was to evaluate health beliefs and behaviors associated with agrochemical exposure among rice farmers. We applied the Health Belief Model, community-based ethnography, and public health risk assessment for this study. Data were collected from 101 rice farmers in Khlong Seven community between January and June 2010. Data comprised observations, unstructured and semistructured interviews, and focus group discussions. We showed that farmers had moderate levels of perceived susceptibility to, severity of, benefits of, and barriers to using agrochemicals safely. The major risk factors related to agrochemical exposure resulted from the misuse of pesticides, including erroneous beliefs of farmers regarding pesticide toxicity, the use of faulty spraying equipment, the lack of proper maintenance of spraying equipment, or the lack of protective gear and appropriate clothing. An intervention program is necessary to improve safety with regard to agrochemicals in the rice Khlong Seven community. © 2012 APJPH.

  9. Measuring Spray Droplet Size from Agricultural Nozzles Using Laser Diffraction

    PubMed Central

    Fritz, Bradley K.; Hoffmann, W. Clint

    2016-01-01

    When making an application of any crop protection material such as an herbicide or pesticide, the applicator uses a variety of skills and information to make an application so that the material reaches the target site (i.e., plant). Information critical in this process is the droplet size that a particular spray nozzle, spray pressure, and spray solution combination generates, as droplet size greatly influences product efficacy and how the spray moves through the environment. Researchers and product manufacturers commonly use laser diffraction equipment to measure the spray droplet size in laboratory wind tunnels. The work presented here describes methods used in making spray droplet size measurements with laser diffraction equipment for both ground and aerial application scenarios that can be used to ensure inter- and intra-laboratory precision while minimizing sampling bias associated with laser diffraction systems. Maintaining critical measurement distances and concurrent airflow throughout the testing process is key to this precision. Real time data quality analysis is also critical to preventing excess variation in the data or extraneous inclusion of erroneous data. Some limitations of this method include atypical spray nozzles, spray solutions or application conditions that result in spray streams that do not fully atomize within the measurement distances discussed. Successful adaption of this method can provide a highly efficient method for evaluation of the performance of agrochemical spray application nozzles under a variety of operational settings. Also discussed are potential experimental design considerations that can be included to enhance functionality of the data collected. PMID:27684589

  10. Effects of spray drying on antioxidant capacity and anthocyanidin content of blueberry by-products.

    PubMed

    Lim, Kar; Ma, Mitzi; Dolan, Kirk D

    2011-09-01

    The effect of spray drying on degradation of nutraceutical components in cull blueberry extract was investigated. Samples collected before and after spray drying were tested for antioxidant capacity using oxygen radical absorbance capacity (ORAC(FL) ) and total phenolics; and for individual anthocyanidins. In Study 1, four different levels of maltodextrin (blueberry solids to maltodextrin ratios of 5: 95, 10: 90, 30: 70, and 50: 50) were spray dried a pilot-scale spray dryer. There was significantly higher retention of nutraceutical components with increased levels of maltodextrin indicating a protective effect of maltodextrin on the nutraceutical components during spray drying. In Study 2, the air inlet temperature of the spray dryer was kept constant for all runs at 150 °C, with 2 different outlet temperatures of 80 and 90 °C. The degradation of nutraceutical components was not significantly different at the 2 selected outlet temperatures. ORAC(FL) reduction for blueberry samples after spray drying was 66.3% to 69.6%. After spray drying, total phenolics reduction for blueberry was 8.2% to 17.5%. Individual anthocyanidin reduction for blueberry was 50% to 70%. The experimental spray dried powders compared favorably to commercial blueberry powders. Results of the study show that use of blueberry by-products is feasible to make a value-added powder. Results can be used by producers to estimate final nutraceutical content of spray-dried blueberry by-products. © 2011 Institute of Food Technologists®

  11. Demonstration and Field Test of airjacket technology

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Faulkner, D.; Fisk, W.J.; Gadgil, A.J.

    1998-06-01

    There are approximately 600,000 paint spray workers in the United States applying paints and coatings with some type of sprayer. Approximately 5% of these spray workers are in the South Coast Air Quality Management District (SCAQMD). These spray workers apply paints or other coatings to products such as bridges, houses, automobiles, wood and metal furniture, and other consumer and industrial products. The materials being sprayed include exterior and interior paints, lacquers, primers, shellacs, stains and varnishes. Our experimental findings indicate that the Airjacket does not significantly reduce the exposure of spray workers to paint fumes during HVLP spraying. The differencemore » between ideal and actual spray paint procedures influence the mechanisms driving spray workers exposures to paint fumes and influence the viability of the Airjacket technology. In the ideal procedure, for which the Airjacket was conceived, the spray worker's exposure to paint fumes is due largely to the formation of a recirculating eddy between the spray worker and the object painted. The Airjacket ejects air to diminish and ventilate this eddy. In actual practice, exposures may result largely from directing paint upstream and from the bounce-back of the air/paint jet of the object being painted. The Airjacket, would not be expected to dramatically reduce exposures to paint fumes when the paint is not directed downstream or when the bounce-back of paint on the object creates a cloud of paint aerosols around the spray worker.« less

  12. Civil Defense, U. S. A.: A Programmed Orientation to Civil Defense. Unit 4. Warning, Emergency Operations, and Support Programs.

    ERIC Educational Resources Information Center

    Defense Civil Preparedness Agency (DOD), Battle Creek, MI.

    The need for, and a description of, emergency functions required to save lives and protect property in nuclear or natural disasters are presented. Topics discussed include: (1) The Civil Defense Warning System, (2) Introduction to the Emergency Operations Program, (3) Five subprograms of the Emergency Operations Program, (4) Emergency Operations…

  13. EVALUATION OF CONVERGENT SPRAY TECHNOLOGYTM SPRAY PROCESS FOR ROOF COATING APPLICATION

    EPA Science Inventory

    The overall goal of this project was to demonstrate the feasibility of Convergent Spray TechnologyTM for the roofing industry. This was accomplished by producing an environmentally compliant coating utilizing recycled materials, a CSTTM spray process portable application cart, a...

  14. The effect of process parameters on Twin Wire Arc spray pattern shape

    DOE PAGES

    Hall, Aaron Christopher; McCloskey, James Francis; Horner, Allison Lynne

    2015-04-20

    A design of experiments approach was used to describe process parameter—spray pattern relationships in the Twin Wire Arc process using zinc feed stock in a TAFA 8835 (Praxair, Concord, NH, USA) spray torch. Specifically, the effects of arc current, primary atomizing gas pressure, and secondary atomizing gas pressure on spray pattern size, spray pattern flatness, spray pattern eccentricity, and coating deposition rate were investigated. Process relationships were investigated with the intent of maximizing or minimizing each coating property. It was determined that spray pattern area was most affected by primary gas pressure and secondary gas pressure. Pattern eccentricity was mostmore » affected by secondary gas pressure. Pattern flatness was most affected by primary gas pressure. Lastly, coating deposition rate was most affected by arc current.« less

  15. The effect of process parameters on Twin Wire Arc spray pattern shape

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hall, Aaron Christopher; McCloskey, James Francis; Horner, Allison Lynne

    A design of experiments approach was used to describe process parameter—spray pattern relationships in the Twin Wire Arc process using zinc feed stock in a TAFA 8835 (Praxair, Concord, NH, USA) spray torch. Specifically, the effects of arc current, primary atomizing gas pressure, and secondary atomizing gas pressure on spray pattern size, spray pattern flatness, spray pattern eccentricity, and coating deposition rate were investigated. Process relationships were investigated with the intent of maximizing or minimizing each coating property. It was determined that spray pattern area was most affected by primary gas pressure and secondary gas pressure. Pattern eccentricity was mostmore » affected by secondary gas pressure. Pattern flatness was most affected by primary gas pressure. Lastly, coating deposition rate was most affected by arc current.« less

  16. Evaporating Spray in Supersonic Streams Including Turbulence Effects

    NASA Technical Reports Server (NTRS)

    Balasubramanyam, M. S.; Chen, C. P.

    2006-01-01

    Evaporating spray plays an important role in spray combustion processes. This paper describes the development of a new finite-conductivity evaporation model, based on the two-temperature film theory, for two-phase numerical simulation using Eulerian-Lagrangian method. The model is a natural extension of the T-blob/T-TAB atomization/spray model which supplies the turbulence characteristics for estimating effective thermal diffusivity within the droplet phase. Both one-way and two-way coupled calculations were performed to investigate the performance of this model. Validation results indicate the superiority of the finite-conductivity model in low speed parallel flow evaporating sprays. High speed cross flow spray results indicate the effectiveness of the T-blob/T-TAB model and point to the needed improvements in high speed evaporating spray modeling.

  17. 76 FR 5187 - Notice of Proposed Information Collection: Comment Request; Emergency Homeowners' Loan Program...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-01-28

    ... Information Collection: Comment Request; Emergency Homeowners' Loan Program Data Elements AGENCY: Office of... following information: Title of Proposal: Emergency Homeowners' Loan Program Data Elements. Description of... of Affected Public: Emergency Homeowners' Loan Program Data Elements. Estimation of the total numbers...

  18. Impact of sea spray on the Yellow and East China Seas thermal structure during the passage of Typhoon Rammasun (2002)

    NASA Astrophysics Data System (ADS)

    Zhang, Lianxin; Zhang, Xuefeng; Chu, P. C.; Guan, Changlong; Fu, Hongli; Chao, Guofang; Han, Guijun; Li, Wei

    2017-10-01

    Strong winds lead to large amounts of sea spray in the lowest part of the atmospheric boundary layer. The spray droplets affect the air-sea heat fluxes due to their evaporation and the momentum due to the change of sea surface, and in turn change the upper ocean thermal structure. In this study, impact of sea spray on upper ocean temperatures in the Yellow and East China Seas (YES) during typhoon Rammasun's passage is investigated using the POMgcs ocean model with a sea spray parameterization scheme, in which the sea spray-induced heat fluxes are based on an improved Fairall's sea spray heat fluxes algorithm, and the sea spray-induced momentum fluxes are derived from an improved COARE version 2.6 bulk model. The distribution of the sea spray mediated turbulent fluxes was primarily located at Rammasun eye-wall region, in accord with the maximal wind speeds regions. When Rammasun enters the Yellow sea, the sea spray mediated latent (sensible) heat flux maximum is enhanced by 26% (13.5%) compared to that of the interfacial latent (sensible) heat flux. The maximum of the total air-sea momentum fluxes is enhanced by 43% compared to the counterpart of the interfacial momentum flux. Furthermore, the sea spray plays a key role in enhancing the intensity of the typhoon-induced "cold suction" and "heat pump" processes. When the effect of sea spray is considered, the maximum of the sea surface cooling in the right side of Rammasun's track is increased by 0.5°C, which is closer to the available satellite observations.

  19. Investigation of Spray Cooling Schemes for Dynamic Thermal Management

    NASA Astrophysics Data System (ADS)

    Yata, Vishnu Vardhan Reddy

    This study aims to investigate variable flow and intermittent flow spray cooling characteristics for efficiency improvement in active two-phase thermal management systems. Variable flow spray cooling scheme requires control of pump input voltage (or speed), while intermittent flow spray cooling scheme requires control of solenoid valve duty cycle and frequency. Several testing scenarios representing dynamic heat load conditions are implemented to characterize the overall performance of variable flow and intermittent flow spray cooling cases in comparison with the reference, steady flow spray cooling case with constant flowrate, continuous spray cooling. Tests are conducted on a small-scale, closed loop spray cooling system featuring a pressure atomized spray nozzle. HFE-7100 dielectric liquid is selected as the working fluid. Two types of test samples are prepared on 10 mm x 10 mm x 2 mm copper substrates with matching size thick film resistors attached onto the opposite side, to generate heat and simulate high heat flux electronic devices. The test samples include: (i) plain, smooth surface, and (ii) microporous surface featuring 100 ?m thick copper-based coating prepared by dual stage electroplating technique. Experimental conditions involve HFE-7100 at atmospheric pressure and 30°C and 10°C subcooling. Steady flow spray cooling tests are conducted at flow rates of 2-5 ml/cm2.s, by controlling the heat flux in increasing steps, and recording the corresponding steady-state temperatures to obtain cooling curves in the form of surface superheat vs. heat flux. Variable flow and intermittent flow spray cooling tests are done at selected flowrate and subcooling conditions to investigate the effects of dynamic flow conditions on maintaining the target surface temperatures defined based on reference steady flow spray cooling performance.

  20. Assessing possible exposures of ground troops to Agent Orange during the Vietnam War: the use of contemporary military records.

    PubMed

    Young, Alvin L; Cecil, Paul F; Guilmartin, John F

    2004-01-01

    Potential exposure of ground troops in Vietnam to Agent Orange and 2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD) remains controversial despite the passage of 30 years since the Vietnam War. Because of uncertainty over the serum dioxin levels in ground troops at the end of their service in Vietnam, attempts have been made to develop a methodology for characterizing exposure of ground troops in Vietnam to Agent Orange and other herbicides based upon historical reconstruction from military records. Historical information is often useful in evaluating and modeling exposure, but such information should be reasonably accurate, complete, and reliable. This paper reviews the procedures and supporting historical information related to the spraying of herbicides in Vietnam. The historical information is classified into two categories: procedural information and operational information. Procedural information covered the process and procedures followed in spraying herbicides from US Air Force fixed wing aircraft (Operation RANCH HAND) in Vietnam, and included approval procedures for spray missions, the criteria required to conduct a mission, the control exercised by the Forward Air Controller and the Tactical Air Control Center and the characteristics of the equipment used to apply the herbicides. Operational information includes data from the RANCH HAND Daily Air Activities Reports, which included geographic locations of specific spray missions, the amount of herbicide sprayed by a specific mission, reports of battle damage to spray aircraft, reports of fighter aircraft support for aerial spray missions, and any comments, such as reasons for canceling a mission. Historical information demonstrates that herbicide spray missions were carefully planned and that spraying only occurred when friendly forces were not located in the target area. RANCH HAND spray missions were either not approved or cancelled if approved when there were friendly forces in the area designated for spraying. Stringent criteria had to be met before spray missions could be approved. The operational information shows that spray missions for both defoliation and crop destruction were conducted in an extremely hostile environment. Heavy 'fighter suppression' with antipersonnel ordnance was used to minimize the impact of hostile ground fire on RANCH HAND aircraft. Procedures were in place that prohibited movement of troops into sprayed areas immediately after a mission due to the possible presence of unexploded ordnance delivered by fighter aircraft supporting RANCH HAND missions. The optimal nature of the spray equipment and application procedures minimized the possibility of significant spray drift. Conclusions. Few friendly troops were sprayed by fixed wing aircraft during Operation RANCH HAND, which delivered 95% of all defoliants used in Vietnam. Similarly, few troops were sprayed during helicopter or surface-based spray operations, which constituted the remaining 5% of defoliants. Detailed policies and procedures for approval and execution of spray missions ensured that friendly forces were not located in the areas targeted for spraying. Fighter aircraft assigned to accompany each spray mission frequently suppressed much of the hostile fire with bombs and other ordnance. Confirmed clearance of the target area was necessary to avoid friendly casualties. Historical records establish that these policies and procedures were strictly followed. Exposure of troops whether from direct spraying or movement through areas recently sprayed was very unlikely. The wartime military records of troop positions and herbicide operations are valuable for some purposes, but have specific limitations in exposure reconstruction. The completeness and accuracy of the geographic data (maps used by RANCH HAND and military ground units) were dependent upon the inherent precision of the map, the accuracy with which it depicted surface features, and the completeness and accuracy of the information on which it is based. Navigation by the crew using visual orientation and reference to the map was the only means that aircrew on spray missions had for establishing their locations. A Forward Air Controller independent of Operation RANCH HAND was present at the location of each spray target immediately before and during spraying operations to verify the target location and ensure that friendly forces were clear of the target area. Anecdotal reports of direct spraying of troops in Vietnam likely reflect the RANCH HAND missions spraying insecticide for mosquito control at regular intervals from March 1967 through February 1972. Outlook. The distribution and levels of serum dioxin in RANCH HAND veterans and the US Army Chemical Corps Vietnam veterans (the unit responsible for helicopter and ground-based spray operations) are distinguishable from typical levels in the population decades after the Vietnam conflict. An exposure model similar to that proposed in the 2003 report of the Institute of Medicine's Committee on 'Characterizing Exposure of Veterans to Agent Orange and Other Herbicides Used in Vietnam' was tested in 1988 by the Centers for Disease Control and Prevention and found to be a poor predictor of absorbed dose of TCDD. Military records during the Vietnam War lack the precision to determine that troops were directly sprayed with herbicides during Operation RANCH HAND, especially given the procedures in place to ensure clearance of friendly forces from the target area and the lack of elevated serum levels of TCDD in ground troops judged to have operated in heavily sprayed areas.

  1. DDT-based indoor residual spraying suboptimal for visceral leishmaniasis elimination in India

    PubMed Central

    Coleman, Michael; Foster, Geraldine M.; Deb, Rinki; Pratap Singh, Rudra; Ismail, Hanafy M.; Shivam, Pushkar; Ghosh, Ayan Kumar; Dunkley, Sophie; Kumar, Vijay; Coleman, Marlize; Hemingway, Janet; Paine, Mark J. I.; Das, Pradeep

    2015-01-01

    Indoor residual spraying (IRS) is used to control visceral leishmaniasis (VL) in India, but it is poorly quality assured. Quality assurance was performed in eight VL endemic districts in Bihar State, India, in 2014. Residual dichlorodiphenyltrichloroethane (DDT) was sampled from walls using Bostik tape discs, and DDT concentrations [grams of active ingredient per square meter (g ai/m2)] were determined using HPLC. Pre-IRS surveys were performed in three districts, and post-IRS surveys were performed in eight districts. A 20% threshold above and below the target spray of 1.0 g ai/m2 was defined as “in range.” The entomological assessments were made in four districts in IRS and non-IRS villages. Vector densities were measured: pre-IRS and 1 and 3 mo post-IRS. Insecticide susceptibility to 4% DDT and 0.05% deltamethrin WHO-impregnated papers was determined with wild-caught sand flies. The majority (329 of 360, 91.3%) of pre-IRS samples had residual DDT concentrations of <0.1 g ai/m2. The mean residual concentration of DDT post-IRS was 0.37 g ai/m2; 84.9% of walls were undersprayed, 7.4% were sprayed in range, and 7.6% were oversprayed. The abundance of sand flies in IRS and non-IRS villages was significantly different at 1 mo post-IRS only. Sand flies were highly resistant to DDT but susceptible to deltamethrin. The Stockholm Convention, ratified by India in 2006, calls for the complete phasing out of DDT as soon as practical, with limited use in the interim where no viable IRS alternatives exist. Given the poor quality of the DDT-based IRS, ready availability of pyrethroids, and susceptibility profile of Indian sand flies, the continued use of DDT in this IRS program is questionable. PMID:26124110

  2. DDT-based indoor residual spraying suboptimal for visceral leishmaniasis elimination in India.

    PubMed

    Coleman, Michael; Foster, Geraldine M; Deb, Rinki; Pratap Singh, Rudra; Ismail, Hanafy M; Shivam, Pushkar; Ghosh, Ayan Kumar; Dunkley, Sophie; Kumar, Vijay; Coleman, Marlize; Hemingway, Janet; Paine, Mark J I; Das, Pradeep

    2015-07-14

    Indoor residual spraying (IRS) is used to control visceral leishmaniasis (VL) in India, but it is poorly quality assured. Quality assurance was performed in eight VL endemic districts in Bihar State, India, in 2014. Residual dichlorodiphenyltrichloroethane (DDT) was sampled from walls using Bostik tape discs, and DDT concentrations [grams of active ingredient per square meter (g ai/m(2))] were determined using HPLC. Pre-IRS surveys were performed in three districts, and post-IRS surveys were performed in eight districts. A 20% threshold above and below the target spray of 1.0 g ai/m(2) was defined as "in range." The entomological assessments were made in four districts in IRS and non-IRS villages. Vector densities were measured: pre-IRS and 1 and 3 mo post-IRS. Insecticide susceptibility to 4% DDT and 0.05% deltamethrin WHO-impregnated papers was determined with wild-caught sand flies. The majority (329 of 360, 91.3%) of pre-IRS samples had residual DDT concentrations of <0.1 g ai/m(2). The mean residual concentration of DDT post-IRS was 0.37 g ai/m(2); 84.9% of walls were undersprayed, 7.4% were sprayed in range, and 7.6% were oversprayed. The abundance of sand flies in IRS and non-IRS villages was significantly different at 1 mo post-IRS only. Sand flies were highly resistant to DDT but susceptible to deltamethrin. The Stockholm Convention, ratified by India in 2006, calls for the complete phasing out of DDT as soon as practical, with limited use in the interim where no viable IRS alternatives exist. Given the poor quality of the DDT-based IRS, ready availability of pyrethroids, and susceptibility profile of Indian sand flies, the continued use of DDT in this IRS program is questionable.

  3. Application of High Performance Computing for Simulations of N-Dodecane Jet Spray with Evaporation

    DTIC Science & Technology

    2016-11-01

    sprays and develop a predictive theory for comparison to measurements in the laboratory of turbulent diesel sprays. 15. SUBJECT TERMS high...models into future simulations of turbulent jet sprays and develop a predictive theory for comparison to measurements in the lab of turbulent diesel ...A critical component of maintaining performance and durability of a diesel engine involves the formation of a fuel-air mixture as a diesel jet spray

  4. "Teaching" an Industrial Robot To Spray

    NASA Technical Reports Server (NTRS)

    Evans, A. R.; Sweet, G. K.

    1982-01-01

    Teaching device, consisting of spacer rod or tube with three-pointed tip and line level, is used during pattern "teach-in" to make sure that robot manipulator holds spray gun perpendicular to surface to be sprayed and at right distance from it. For slanted surfaces angle adapter is added between spacer rod and line-level indicator. Angle is determined by slope of surface to be sprayed, thus allowing a perpendicular spray pattern against even slanted surfaces.

  5. Preparation and in vivo absorption evaluation of spray dried powders containing salmon calcitonin loaded chitosan nanoparticles for pulmonary delivery

    PubMed Central

    Sinsuebpol, Chutima; Chatchawalsaisin, Jittima; Kulvanich, Poj

    2013-01-01

    Purpose The aim of the present study was to prepare inhalable co-spray dried powders of salmon calcitonin loaded chitosan nanoparticles (sCT-CS-NPs) with mannitol and investigate pulmonary absorption in rats. Methods The sCT-CS-NPs were prepared by the ionic gelation method using sodium tripolyphosphate (TPP) as a cross-linking polyion. Inhalable dry powders were obtained by co-spray drying aqueous dispersion of sCT-CS-NPs and mannitol. sCT-CS-NPs co-spray dried powders were characterized with respect to morphology, particle size, powder density, aerodynamic diameter, protein integrity, in vitro release of sCT, and aerosolization. The plasmatic sCT levels following intratracheal administration of sCT-CS-NPs spray dried powders to the rats was also determined. Results sCT-CS-NPs were able to be incorporated into mannitol forming inhalable microparticles by the spray drying process. The sCT-CS-NPs/mannitol ratios and spray drying process affected the properties of the microparticles obtained. The conformation of the secondary structures of sCTs was affected by both mannitol content and spray dry inlet temperature. The sCT-CS-NPs were recovered after reconstitution of spray dried powders in an aqueous medium. The sCT release profile from spray dried powders was similar to that from sCT-CS-NPs. In vitro inhalation parameters measured by the Andersen cascade impactor indicated sCT-CS-NPs spray dried powders having promising aerodynamic properties for deposition in the deep lung. Determination of the plasmatic sCT levels following intratracheal administration to rats revealed that the inhalable sCT-CS NPs spray dried powders provided higher protein absorption compared to native sCT powders. Conclusion The sCT-CS-NPs with mannitol based spray dried powders were prepared to have appropriate aerodynamic properties for pulmonary delivery. The developed system was able to deliver sCT via a pulmonary route into the systemic circulation. PMID:24039397

  6. Field experiment on spray drift: deposition and airborne drift during application to a winter wheat crop.

    PubMed

    Wolters, André; Linnemann, Volker; van de Zande, Jan C; Vereecken, Harry

    2008-11-01

    A field experiment was performed to evaluate various techniques for measuring spray deposition and airborne drift during spray application to a winter wheat crop. The application of a spraying agent containing the fluorescent dye Brilliant Sulfo Flavine by a conventional boom sprayer was done according to good agricultural practice. Deposition was measured by horizontal collectors in various arrangements in and outside the treated area. Airborne spray drift was measured both with a passive and an active air collecting system. Spray deposits on top of the treated canopy ranged between 68 and 71% of the applied dose and showed only small differences for various arrangements of the collectors. Furthermore, only small variations were measured within the various groups of collectors used for these arrangements. Generally, the highest spray deposition outside the treated area was measured close to the sprayed plot and was accompanied by a high variability of values, while a rapid decline of deposits was detected in more remote areas. Estimations of spray deposits with the IMAG Drift Calculator were in accordance with experimental findings only for areas located at a distance of 0.5-4.5 m from the last nozzle, while there was an overestimation of a factor of 4 at a distance of 2.0-3.0 m, thus revealing a high level of uncertainty of the estimation of deposition for short distances. Airborne spray drift measured by passive and active air collecting systems was approximately at the same level, when taking into consideration the collector efficiency of the woven nylon wire used as sampling material for the passive collecting system. The maximum value of total airborne spray drift for both spray applications (0.79% of the applied dose) was determined by the active collecting system. However, the comparatively high variability of measurements at various heights above the soil by active and passive collecting systems revealed need for further studies to elucidate the spatial pattern of airborne spray drift.

  7. Preparation and in vivo absorption evaluation of spray dried powders containing salmon calcitonin loaded chitosan nanoparticles for pulmonary delivery.

    PubMed

    Sinsuebpol, Chutima; Chatchawalsaisin, Jittima; Kulvanich, Poj

    2013-01-01

    The aim of the present study was to prepare inhalable co-spray dried powders of salmon calcitonin loaded chitosan nanoparticles (sCT-CS-NPs) with mannitol and investigate pulmonary absorption in rats. The sCT-CS-NPs were prepared by the ionic gelation method using sodium tripolyphosphate (TPP) as a cross-linking polyion. Inhalable dry powders were obtained by co-spray drying aqueous dispersion of sCT-CS-NPs and mannitol. sCT-CS-NPs co-spray dried powders were characterized with respect to morphology, particle size, powder density, aerodynamic diameter, protein integrity, in vitro release of sCT, and aerosolization. The plasmatic sCT levels following intratracheal administration of sCT-CS-NPs spray dried powders to the rats was also determined. sCT-CS-NPs were able to be incorporated into mannitol forming inhalable microparticles by the spray drying process. The sCT-CS-NPs/mannitol ratios and spray drying process affected the properties of the microparticles obtained. The conformation of the secondary structures of sCTs was affected by both mannitol content and spray dry inlet temperature. The sCT-CS-NPs were recovered after reconstitution of spray dried powders in an aqueous medium. The sCT release profile from spray dried powders was similar to that from sCT-CS-NPs. In vitro inhalation parameters measured by the Andersen cascade impactor indicated sCT-CS-NPs spray dried powders having promising aerodynamic properties for deposition in the deep lung. Determination of the plasmatic sCT levels following intratracheal administration to rats revealed that the inhalable sCT-CS NPs spray dried powders provided higher protein absorption compared to native sCT powders. The sCT-CS-NPs with mannitol based spray dried powders were prepared to have appropriate aerodynamic properties for pulmonary delivery. The developed system was able to deliver sCT via a pulmonary route into the systemic circulation.

  8. Quantitative X-ray measurements of high-pressure fuel sprays from a production heavy duty diesel injector

    NASA Astrophysics Data System (ADS)

    Ramírez, A. I.; Som, S.; Aggarwal, Suresh K.; Kastengren, A. L.; El-Hannouny, E. M.; Longman, D. E.; Powell, C. F.

    2009-07-01

    A quantitative and time-resolved X-ray radiography technique has been used for detailed measurements of high-pressure fuel sprays in the near-nozzle region of a diesel engine injector. The technique provides high spatial and temporal resolution, especially in the relatively dense core region. A single spray plume from a hydraulically actuated electronically controlled unit injector model 315B injector with a 6-hole nozzle was isolated and studied at engine-like densities for two different injection pressures. Optical spray imaging was also employed to evaluate the effectiveness of the shield used to isolate a single spray plume. The steady state fuel distributions for both injection pressures are similar and show a dense spray region along the axis of the spray, with the on-axis spray density decreasing as the spray progresses downstream. The higher injection pressure case exhibits a larger cone angle and spray broadening at the exit of the nozzle. For some time periods, the near-nozzle penetration speed is lower for the high injection pressure case than the low injection pressure case, which is unexpected, but can be attributed to the needle and flow dynamics inside the injector causing slower pressure build-up for the former case. Rate of injection testing was performed to further understand near-nozzle behavior. Mass distribution data were obtained and used to find mass-averaged velocity of the spray. Comparisons of the radiography data with that from a common rail single-hole light duty injectors under similar injection conditions show several significant differences. The current data show a larger cone angle and lower penetration speed than that from the light-duty injector. Moreover, these data display a Gaussian mass distribution across the spray near the injector, whereas in previous light-duty injector measurements, the mass distribution had steeper sides and a flatter peak. Measurements are also used to examine the spray models in the STAR-CD software.

  9. 21 CFR 524.1662a - Oxytetracycline and hydrocortisone spray.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 6 2014-04-01 2014-04-01 false Oxytetracycline and hydrocortisone spray. 524... ANIMAL DRUGS § 524.1662a Oxytetracycline and hydrocortisone spray. (a) Specifications. Each 3-ounce unit of oxytetracycline hydrochloride and hydrocortisone spray contains 300 milligrams of oxytetracycline...

  10. SPRAYTRAN USER'S GUIDE: A GIS-BASED ATMOSPHERIC SPRAY DROPLET DISPERSION MODELING SYSTEM

    EPA Science Inventory

    The offsite drift of pesticide from spray operations is an ongoing source of concern. The SPRAY TRANsport (SPRAYTRAN) system, documented in this report, incorporates the near-field spray application model, AGDISP, into a meso-scale atmospheric transport model. The AGDISP model ...

  11. VERIFYING THE PERFORMANCE OF PESTICIDE SPRAY DRIFT REDUCTION TECHNOLOGIES

    EPA Science Inventory

    Application of pesticide sprays usually results in formation of small spray droplets which can drift with air currents to nearby sensitive sites. A number of technologies offer the potential to reduce the amount of spray drift from pesticide applications. Acceptance and use of ...

  12. Spatial distribution visualization of PWM continuous variable-rate spray

    USDA-ARS?s Scientific Manuscript database

    Chemical application is a dynamic spatial distribution process, during which spray liquid covers the targets with certain thickness and uniformity. Therefore, it is important to study the 2-D and 3-D (dimensional) spray distribution to evaluate spraying quality. The curve-surface generation methods ...

  13. Developments in the formulation and delivery of spray dried vaccines.

    PubMed

    Kanojia, Gaurav; Have, Rimko Ten; Soema, Peter C; Frijlink, Henderik; Amorij, Jean-Pierre; Kersten, Gideon

    2017-10-03

    Spray drying is a promising method for the stabilization of vaccines, which are usually formulated as liquids. Usually, vaccine stability is improved by spray drying in the presence of a range of excipients. Unlike freeze drying, there is no freezing step involved, thus the damage related to this step is avoided. The edge of spray drying resides in its ability for particles to be engineered to desired requirements, which can be used in various vaccine delivery methods and routes. Although several spray dried vaccines have shown encouraging preclinical results, the number of vaccines that have been tested in clinical trials is limited, indicating a relatively new area of vaccine stabilization and delivery. This article reviews the current status of spray dried vaccine formulations and delivery methods. In particular it discusses the impact of process stresses on vaccine integrity, the application of excipients in spray drying of vaccines, process and formulation optimization strategies based on Design of Experiment approaches as well as opportunities for future application of spray dried vaccine powders for vaccine delivery.

  14. Characteristics of combustion flame sprayed nickel aluminum using a Coanda Assisted Spray Manipulation collar for off-normal deposits

    NASA Astrophysics Data System (ADS)

    Archibald, Reid S.

    A novel flame spray collar called the Coanda Assisted Spray Manipulation collar (CSM) has been tested for use on the Sulzer Metco 5P II combustion flame spray gun. A comparison study of the stock nozzle and the CSM has been performed by evaluating the porosity, surface roughness, microhardness, tensile strength and microscopy of normal and off-normal sprayed NiAl deposits. The use of the CSM collar resulted in the need to position the sprayed coupons closer to the gun, which in turn affected the particle impact energy and particle temperatures of the NiAl powder. For the CSM, porosities had a larger scatterband, surface roughness was comparably the same, microhardness was lower, and tensile strength was higher. The microscopy analysis revealed a greater presence of unmelted particles and steeper intersplat boundaries for the CSM. For both processes, the porosity and surface roughness increased and the microhardness decreased as the spray angle decreased.

  15. Measurement of Ambient Air Motion of D. I. Gasoline Spray by LIF-PIV

    NASA Astrophysics Data System (ADS)

    Yamakawa, Masahisa; Isshiki, Seiji; Yoshizaki, Takuo; Nishida, Keiya

    Ambient air velocity distributions in and around a D. I. gasoline spray were measured using a combination of LIF and PIV techniques. A rhodamine and water solution was injected into ambient air to disperse the fine fluorescent liquid particles used as tracers. A fuel spray was injected into the fluorescent tracer cloud and was illuminated by an Nd: YAG laser light sheet (532nm). The scattered light from the spray droplets and tracers was cut off by a high-pass filter (>560nm). As the fluorescence (>600nm) was transmitted through the high-pass filter, the tracer images were captured using a CCD camera and the ambient air velocity distribution could be obtained by PIV based on the images. This technique was applied to a D. I. gasoline spray. The ambient air flowed up around the spray and entered into the tail of the spray. Furthermore, the relative velocity between the spray and ambient air was investigated.

  16. Study of Heterogeneous Structure in Diesel Fuel Spray by Using Micro-Probe L2F

    NASA Astrophysics Data System (ADS)

    Sakaguchi, Daisaku; Yamamoto, Shohei; Ueki, Hironobu; Ishdia, Masahiro

    A L2F (Laser 2-Focus velocimeter) was applied for the measurements of the velocity and size of droplets in diesel fuel sprays. The micro-scale probe of the L2F has an advantage in avoiding the multiple scattering from droplets in a dense region of fuel sprays. A data sampling rate of 15MHz has been achieved in the L2F system for detecting almost all of the droplets which passed through the measurement probe. Diesel fuel was injected into the atmosphere by using a common rail injector. Measurement positions were located along the spray axis at 10, 15, 20, 25, and 30 mm from the nozzle exit. Measurement result showed that the velocity and size of droplets decreased and the number density of droplets increased along the spray axis. It was clearly shown that the mass flow rate in the spray was highest near the spray tip and was lower inside the spray.

  17. Spray visualization of alternative fuels at hot ambient conditions

    NASA Astrophysics Data System (ADS)

    Kannaiyan, Kumaran; Sadr, Reza

    2017-11-01

    Gas-to-Liquid (GTL) has gained significant interest as drop-in alternative jet fuel owing to its cleaner combustion characteristics. The physical and evaporation properties of GTL fuels are different from those of the conventional jet fuels. Those differences will have an effect on the spray, and in turn, the combustion performance. In this study, the non-reacting near nozzle spray dynamics such as spray cone angle, liquid sheet breakup and liquid velocity of GTL fuel will be investigated and compared with those of the conventional jet fuel. This work is a follow up of the preliminary study performed at atmospheric ambient conditions where differences were observed in the near nozzle spray characteristics between the fuels. Whereas, in this study the spray visualization will be performed in a hot and inert environment to account for the difference in evaporation characteristics of the fuels. The spray visualization images will be captured using the shadowgraph technique. A rigorous statistical analysis of the images will be performed to compare the spray dynamics between the fuels.

  18. Endospore production allows using spray-drying as a possible formulation system of the biocontrol agent Bacillus subtilis CPA-8.

    PubMed

    Yánez-Mendizabal, V; Viñas, I; Usall, J; Cañamás, T; Teixidó, N

    2012-04-01

    The role of endospore production by Bacillus subtilis CPA-8 on survival during spray-drying was investigated by comparison with a non-spore-forming biocontrol agent Pantoea agglomerans CPA-2. Endospore formation promoted heat resistance in CPA-8 depending on growth time (72 h cultures were more resistant than 24 h ones). The survival of CPA-8 and CPA-2 after spray-drying was determined after being grown in optimised media for 24 and 72 h. Spray-dried 72 h CPA-8 had the best survival (32%), while CPA-2 viability was less than 2%. CPA-8 survival directly related with its ability to produce endospores. Spray-dried CPA-8 reduced Monilinia fructicola conidia germination similarly to fresh cells, demonstrating that spray-drying did not adversely affect biocontrol efficacy. Endospore production thus improves CPA-8 resistance to spray-drying. These results can provide a reliable basis for optimising of the spray-drying formulation process for CPA-8 and other microorganisms.

  19. U.S. Army Toxic Metal Reduction Program: Demonstrating Alternatives to Hexavalent Chromium and Cadmium in Surface Finishing

    DTIC Science & Technology

    2014-11-18

    only) Medium Cal: M242 25mm Bushmaster, M230 30mm, GAU-12 25mm, 30mm Bushmaster II, EAPS 50mm POC: Vic Champagne , ARL, victor.k.champagne.civ...Shielding for Electronic Shelters) POC: Vic Champagne , ARL, victor.k.champagne.civ@mail.mil Cold Spray – Portable System and Internal Diameter

  20. 7 CFR 701.151 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... AGRICULTURAL CONSERVATION PROGRAM EMERGENCY CONSERVATION PROGRAM, EMERGENCY FOREST RESTORATION PROGRAM, AND CERTAIN RELATED PROGRAMS PREVIOUSLY ADMINISTERED UNDER THIS PART Emergency Conservation Program § 701.151... irrigation system. Barn means a structure used for the housing of animals or farm equipment. Commercial...

  1. 7 CFR 701.151 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... AGRICULTURAL CONSERVATION PROGRAM EMERGENCY CONSERVATION PROGRAM, EMERGENCY FOREST RESTORATION PROGRAM, AND CERTAIN RELATED PROGRAMS PREVIOUSLY ADMINISTERED UNDER THIS PART Emergency Conservation Program § 701.151... irrigation system. Barn means a structure used for the housing of animals or farm equipment. Commercial...

  2. 7 CFR 701.151 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... AGRICULTURAL CONSERVATION PROGRAM EMERGENCY CONSERVATION PROGRAM, EMERGENCY FOREST RESTORATION PROGRAM, AND CERTAIN RELATED PROGRAMS PREVIOUSLY ADMINISTERED UNDER THIS PART Emergency Conservation Program § 701.151... irrigation system. Barn means a structure used for the housing of animals or farm equipment. Commercial...

  3. 7 CFR 701.151 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... AGRICULTURAL CONSERVATION PROGRAM EMERGENCY CONSERVATION PROGRAM, EMERGENCY FOREST RESTORATION PROGRAM, AND CERTAIN RELATED PROGRAMS PREVIOUSLY ADMINISTERED UNDER THIS PART Emergency Conservation Program § 701.151... irrigation system. Barn means a structure used for the housing of animals or farm equipment. Commercial...

  4. 25 CFR 170.921 - What emergency or disaster assistance programs are available?

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... have been damaged due to natural disasters (floods, hurricanes, tornadoes, etc.). (b) The Federal... 25 Indians 1 2010-04-01 2010-04-01 false What emergency or disaster assistance programs are... emergency or disaster assistance programs are available? (a) FHWA operates two emergency relief programs: (1...

  5. 25 CFR 170.921 - What emergency or disaster assistance programs are available?

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... have been damaged due to natural disasters (floods, hurricanes, tornadoes, etc.). (b) The Federal... 25 Indians 1 2011-04-01 2011-04-01 false What emergency or disaster assistance programs are... emergency or disaster assistance programs are available? (a) FHWA operates two emergency relief programs: (1...

  6. 25 CFR 170.921 - What emergency or disaster assistance programs are available?

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... have been damaged due to natural disasters (floods, hurricanes, tornadoes, etc.). (b) The Federal... 25 Indians 1 2013-04-01 2013-04-01 false What emergency or disaster assistance programs are... emergency or disaster assistance programs are available? (a) FHWA operates two emergency relief programs: (1...

  7. 25 CFR 170.921 - What emergency or disaster assistance programs are available?

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... have been damaged due to natural disasters (floods, hurricanes, tornadoes, etc.). (b) The Federal... 25 Indians 1 2014-04-01 2014-04-01 false What emergency or disaster assistance programs are... emergency or disaster assistance programs are available? (a) FHWA operates two emergency relief programs: (1...

  8. 25 CFR 170.921 - What emergency or disaster assistance programs are available?

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... have been damaged due to natural disasters (floods, hurricanes, tornadoes, etc.). (b) The Federal... 25 Indians 1 2012-04-01 2011-04-01 true What emergency or disaster assistance programs are... emergency or disaster assistance programs are available? (a) FHWA operates two emergency relief programs: (1...

  9. 44 CFR 16.151 - Program accessibility: New construction and alterations.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 44 Emergency Management and Assistance 1 2010-10-01 2010-10-01 false Program accessibility: New construction and alterations. 16.151 Section 16.151 Emergency Management and Assistance FEDERAL EMERGENCY... HANDICAP IN PROGRAMS OR ACTIVITIES CONDUCTED BY THE FEDERAL EMERGENCY MANAGEMENT AGENCY § 16.151 Program...

  10. Spray distribution evaluation of different settings of a hand-held-trolley sprayer used in greenhouse tomato crops.

    PubMed

    Llop, Jordi; Gil, Emilio; Gallart, Montserrat; Contador, Felipe; Ercilla, Mireia

    2016-03-01

    Hand-held-trolley sprayers have recently been promoted to improve spray application techniques in greenhouses in south-eastern Spain. However, certain aspects remain to be improved. A modified hand-held-trolley sprayer was evaluated under two different canopy conditions (high and low canopy density) and with several sprayer settings (nozzle type, air assistance and spray volume). In this study, the deposition, coverage and uniformity of distribution of the spray on the canopy have been assessed. The deposition on leaves was significantly higher when flat-fan nozzles and air assistance were used at both high and low spray volumes. No differences were detected between the reference system at a high spray volume and the modified trolley at a low spray volume. Flat-fan nozzles with air assistance increased penetrability into the canopy. Air assistance and flat-fan nozzles allow volume rates to be reduced while maintaining or improving spray quality distribution. The working parameters of hand-held sprayers must be considered to reduce environmental risk and increase the efficacy of the spraying process. © 2015 Society of Chemical Industry. © 2015 Society of Chemical Industry.

  11. Balanced Rotating Spray Tank and Pipe Cleaning and Cleanliness Verification System

    NASA Technical Reports Server (NTRS)

    Caimi, Raoul E. B. (Inventor); Thaxton, Eric A. (Inventor)

    1998-01-01

    A system for cleaning and verifying the cleanliness of the interior surfaces of hollow items, such as small bottles, tanks, pipes and tubes, employs a rotating spray head for supplying a gas-liquid cleaning mixture to the item's surface at a supersonic velocity. The spray head incorporates a plurality of nozzles having diverging cross sections so that the incoming gas-liquid mixture is first converged within the spray head and then diverged through the nozzles, thereby accelerating the mixture to a supersonic velocity. In the preferred embodiment, three nozzles are employed; one forwardly facing nozzle at the end of the spray head and two oppositely facing angled nozzles exiting on opposite sides of the spray head which balance each other, and therefore impart no net side load on the spray head. A drive mechanism is provided to rotate the spray head and at the same time move the head back and forth within the item to be cleaned. The drive mechanism acts on a long metal tube to which the spray head is fixed, and thus no moving parts are exposed to the interior surfaces of the items to be cleaned, thereby reducing the risk of contamination.

  12. Inhalational and dermal exposures during spray application of biocides.

    PubMed

    Berger-Preiss, Edith; Boehncke, Andrea; Könnecker, Gustav; Mangelsdorf, Inge; Holthenrich, Dagmar; Koch, Wolfgang

    2005-01-01

    Data on inhalational and potential dermal exposures during spray application of liquid biocidal products were generated. On the one hand, model experiments with different spraying devices using fluorescent tracers were carried out to investigate the influence of parameters relevant to the exposure (e.g. spraying equipment, nozzle size, direction of application). On the other hand, measurements were performed at selected workplaces (during disinfection operations in food and feed areas; pest control operations for private, public and veterinary hygiene; wood protection and antifouling applications) after application of biocidal products such as Empire 20, Responsar SC, Omexan-forte, Actellic, Perma-forte; Fendona SC, Pyrethrum mist; CBM 8, Aldekol Des 03, TAD CID, Basileum, Basilit. The measurements taken in the model rooms demonstrated dependence of the inhalation exposure on the type of spraying device used, in the following order: "spraying with low pressure" < "airless spraying" < "fogging" indicating that the particle diameter of the released spray droplets is the most important parameter. In addition inhalation exposure was lowest when the spraying direction was downward. Also for the potential dermal exposure, the spraying direction was of particular importance: overhead spraying caused the highest contamination of body surfaces. The data of inhalational and potential dermal exposures gained through workplace measurements showed considerable variation. During spraying procedures with low-pressure equipments, dose rates of active substances inhaled by the operators ranged from 7 to 230 microg active substance (a.s.)/h. An increase in inhaled dose rates (6-33 mg a.s./h) was observed after use of high application volumes/time unit during wood protection applications indoors. Spraying in the veterinary sector using medium-pressure sprayers led to inhaled dose rates between 2 and 24mga.s./h. The highest inhaled dose rates were measured during fogging (114 mg a.s./h) and after-high-pressure applications in the antifouling sector (110-300 mg a.s./h). The potential dermal exposure of spray operators was lowest (dose rates from 0.2 to 7 mg a.s./h) in the areas of food and feed disinfection and private and public hygiene during spraying with low-pressure devices. During fogging, wood protection and antifouling applications, high-potential dermal exposures of the operators were determined. Dermal dose rates varied between 100 and 34,000 mg a.s./h.

  13. Spray Drift Reduction Evaluations of Spray Nozzles Using a Standardized Testing Protocol

    DTIC Science & Technology

    2010-07-01

    Drop Size Characteristics in a Spray Using Optical Nonimaging Light-Scattering Instruments,” Annual Book of ASTM Standards, Vol. 14-02, ASTM...Test Method for Determining Liquid Drop Size Characteristics in a Spray Using Optical Non- imaging Light-Scattering Instruments 22. AGDISP Model

  14. Review of patents and application of spray drying in pharmaceutical, food and flavor industry.

    PubMed

    Patel, Bhavesh B; Patel, Jayvadan K; Chakraborty, Subhashis

    2014-04-01

    Spray drying has always remained an energetic field of innovation in pharmaceutical, food and flavor industry since last couple of decades. The current communication embodies an in-depth application of spray drying in pulmonary drug delivery for production of uniform and respirable size particles suitable for nebulizers, dry powder inhalers (DPI) and pressurized metered dose inhalers (pMDI). The review also highlights spray drying application in the manufacturing of mucoadhesive formulation suitable for nasal cavities to improve the drug absorption and bioavailability. Recent research works and patents filed by various researchers on spray drying technology for solubility enhancement have also been accentuated. Benefits of spray drying in production of dry flavorings to meet a product with maximum yield and least flavor loss are also discussed. The use of spray drying in production of various food products like milk or soymilk powder, tomato pulp, dry fruit juice etc, and in encapsulation of vegetable oil or fish oil and dry creamer has been discussed. Current review also highlights the application of spray drying in the biotechnology field like production of dry influenza or measles vaccine as well as application in ceramic industry. Spray drying based patents issued by the U.S. Patent and Trademark Office in the area of drug delivery have also been included in the current review to emphasize importance of spray drying in the recent research scenario.

  15. Quality characteristic of spray-drying egg white powders.

    PubMed

    Ma, Shuang; Zhao, Songning; Zhang, Yan; Yu, Yiding; Liu, Jingbo; Xu, Menglei

    2013-10-01

    Spray drying is a useful method for developing egg process and utilization. The objective of this study was to evaluate effects on spray drying condition of egg white. The optimized conditions were spraying flow 22 mL/min, feeding temperature 39.8 °C and inlet-air temperature 178.2 °C. Results of sulfydryl (SH) groups measurement indicated conformation structure have changed resulting in protein molecule occur S-S crosslinking phenomenon when heating. It led to free SH content decreased during spray drying process. There was almost no change of differential scanning calorimetry between fresh egg white and spray-drying egg white powder (EWP). For a given protein, the apparent SH reactivity is in turn influenced by the physico-chemical characteristics of the reactant. The phenomenon illustrated the thermal denaturation of these proteins was unrelated to their free SH contents. Color measurement was used to study browning level. EWP in optimized conditions revealed insignificant brown stain. Swelling capacity and scanning electron micrograph both proved well quality characteristic of spray-drying EWP. Results suggested spray drying under the optimized conditions present suitable and alternative method for egg processing industrial implementation. Egg food industrialization needs new drying method to extend shelf-life. The purpose of the study was to provide optimal process of healthy and nutritional instant spray-drying EWP and study quality characteristic of spray-drying EWP.

  16. Investigation of the spray characteristics for a secondary fuel injection nozzle using a digital image processing method

    NASA Astrophysics Data System (ADS)

    Jeong, Haeyoung; Lee, Kihyung; Ikeda, Yuji

    2007-05-01

    There are many ways to reduce diesel engine exhaust emissions. However, NOx emission is difficult to reduce because the hydrocarbon (HC) concentration in a diesel engine is not sufficient for NOx conversion. Therefore, in order to create stoichiometric conditions in the De-NOx catalyst, a secondary injection system is designed to inject liquid HC into the exhaust pipe. The atomization and distribution characteristics of the HC injected from a secondary injector are key technologies to obtain a high NOx conversion because inhomogeneous droplets of injected HC cause not only high fuel consumption but also deterioration of NOx emission. This paper describes the spray characteristics of a secondary injector including the spray angle, penetration length and breakup behaviour of the spray to optimize the reduction rate of the NOx catalyst. In this study, various optical diagnostics were applied to investigate these spray characteristics, the atomization mechanism and spray developing process. The visualization and image processing method for the spray pulsation were developed by high speed photography. The influence of the fuel supply pressure on the spray behaviour and a more detailed spray developing process have been analysed experimentally using image processing. Finally, the experimental results were used to correlate the spray structure to the injection system performance and to provide a design guide for a secondary injector nozzle.

  17. Spark Ignition of Monodisperse Fuel Sprays. Ph.D. Thesis

    NASA Technical Reports Server (NTRS)

    Danis, Allen M.; Cernansky, Nicholas P.; Namer, Izak

    1987-01-01

    A study of spark ignition energy requirements was conducted with a monodisperse spray system allowing independent control of droplet size, equivalent ratio, and fuel type. Minimum ignition energies were measured for n-heptane and methanol sprays characterized at the spark gap in terms of droplet diameter, equivalence ratio (number density) and extent of prevaporization. In addition to sprays, minimum ignition energies were measured for completely prevaporized mixtures of the same fuels over a range of equivalence ratios to provide data at the lower limit of droplet size. Results showed that spray ignition was enhanced with decreasing droplet size and increasing equivalence ratio over the ranges of the parameters studied. By comparing spray and prevaporized ignition results, the existence of an optimum droplet size for ignition was indicated for both fuels. Fuel volatility was seen to be a critical factor in spray ignition. The spray ignition results were analyzed using two different empirical ignition models for quiescent mixtures. Both models accurately predicted the experimental ignition energies for the majority of the spray conditions. Spray ignition was observed to be probabilistic in nature, and ignition was quantified in terms of an ignition frequency for a given spark energy. A model was developed to predict ignition frequencies based on the variation in spark energy and equivalence ratio in the spark gap. The resulting ignition frequency simulations were nearly identical to the experimentally observed values.

  18. Sustained release of diltiazem HCl tableted after co-spray drying and physical mixing with PVAc and PVP.

    PubMed

    Al-Zoubi, Nizar; Al-Obaidi, Ghada; Tashtoush, Bassam; Malamataris, Stavros

    2016-01-01

    In this work, aqueous diltiazem HCl and polyvinyl-pyrrolidone (PVP) solutions were mixed with Kollicoat SR 30D and spray dried to microparticles of different drug:excipient ratio and PVP content. Co-spray dried products and physical mixtures of drug, Kollidon SR and PVP were tableted. Spray drying process, co-spray dried products and compressibility/compactability of co-spray dried and physical mixtures, as well as drug release and water uptake of matrix-tablets was evaluated. Simple power equation fitted drug release and water uptake (R(2) > 0.909 and 0.938, respectively) and correlations between them were examined. Co-spray dried products with PVP content lower than in physical mixtures result in slower release, while at equal PVP content (19 and 29% w/w of excipient) in similar release (f2 > 50). Increase of PVP content increases release rate and co-spray drying might be an alternative, when physical mixing is inadequate. Co-spray dried products show better compressibility/compatibility but higher stickiness to the die-wall compared to physical mixtures. SEM observations and comparison of release and swelling showed that distribution of tableted component affects only the swelling, while PVP content for both co-spray dried and physical mixes is major reason for release alterations and an aid for drug release control.

  19. Spray formation of biodiesel-water in air-assisted atomizer using Schlieren photography

    NASA Astrophysics Data System (ADS)

    Amirnordin, S. H.; Khalid, A.; Sapit, A.; Salleh, H.; Razali, A.; Fawzi, M.

    2016-11-01

    Biodiesels are attractive renewable energy sources, particularly for industrial boiler and burner operators. However, biodiesels produce higher nitrogen oxide (NOx) emissions compared with diesel. Although water-emulsified fuels can lower NOx emissions by reducing flame temperature, its influence on atomization needs to be investigated further. This study investigates the effects of water on spray formation in air-assisted atomizers. The Schlieren method was used to capture the spray images in terms of tip penetration, spray angle, and spray area. The experiment used palm oil biodiesel at different blending ratios (B5, B10, and B15) and water contents (0vol%-15vol%). Results show that water content in the fuel increases the spray penetration and area but reduces the spray angle because of the changes in fuel properties. Therefore, biodiesel-water application is applicable to burner systems.

  20. Factors influencing the effective spray cone angle of pressure-swirl atomizers

    NASA Astrophysics Data System (ADS)

    Chen, S. K.; Lefebvre, A. H.; Rollbuhler, J.

    1992-01-01

    The spray cone angles produced by several simplex pressure-swirl nozzles are examined using three liquids whose viscosities range from 0.001 to 0.012 kg/ms (1 to 12 cp). Measurements of both the visible spray cone angle and the effective spray cone angle are carried out over wide ranges of injection pressure and for five different values of the discharge orifice length/diameter ratio. The influence of the number of swirl chamber feed slots on spray cone angle is also examined. The results show that the spray cone angle widens with increase in injection pressure but is reduced by increases in liquid viscosity and/or discharge orifice length/diameter ratio. Variation in the number of swirl chamber feed slots between one and three has little effect on the effective spray cone angle.

  1. Experimental and Numerical Analysis of the Cooling Performance of Water Spraying Systems during a Fire

    PubMed Central

    Chen, YaoHan; Su, ChungHwei; Tseng, JoMing; Li, WunJie

    2015-01-01

    The water spray systems are effective protection systems in the confined or unconfined spaces to avoid the damage to building structures since the high temperature when fires occur. NFPA 15 and 502 have suggested respectively that the factories or vehicle tunnels install water spray systems to protect the machinery and structures. This study discussed the cooling effect of water spray systems in experimental and numerical analyses. The actual combustion of woods were compared with the numerical simulations. The results showed that although the flame continued, the cooling effects by water spraying process within 120 seconds were obvious. The results also indicated that the simulation results of the fifth version Fire Dynamics Simulator (FDS) overestimated the space temperature before water spraying in the case of the same water spray system. PMID:25723519

  2. The study on the interdependence of spray characteristics and evaporation history of fuel spray in high temperature air crossflow

    NASA Astrophysics Data System (ADS)

    Zhu, J. Y.; Chin, J. S.

    1986-06-01

    A numerical calculation method is used to predict the variation of the characteristics of fuel spray moving in a high temperature air crossflow, mainly, Sauter mean diameter SMD, droplet size distribution index N of Rosin-Rammler distribution and evaporation percentage changing with downstream distance X from the nozzle. The effect of droplet heat-up period evaporation process and forced convection are taken into full account; thus, the calculation model is a very good approximation to the process of spray evaporation in a practical combustor, such as ramjet, aero-gas turbine, liquid propellant rocket, diesel and other liquid fuel-powered combustion devices. The changes of spray characteristics N, SMD and spray evaporation percentage with air velocity, pressure, temperature, fuel injection velocity, and the initial spray parameters are presented.

  3. Effects of Sea-Surface Waves and Ocean Spray on Air-Sea Momentum Fluxes

    NASA Astrophysics Data System (ADS)

    Zhang, Ting; Song, Jinbao

    2018-04-01

    The effects of sea-surface waves and ocean spray on the marine atmospheric boundary layer (MABL) at different wind speeds and wave ages were investigated. An MABL model was developed that introduces a wave-induced component and spray force to the total surface stress. The theoretical model solution was determined assuming the eddy viscosity coefficient varied linearly with height above the sea surface. The wave-induced component was evaluated using a directional wave spectrum and growth rate. Spray force was described using interactions between ocean-spray droplets and wind-velocity shear. Wind profiles and sea-surface drag coefficients were calculated for low to high wind speeds for wind-generated sea at different wave ages to examine surface-wave and ocean-spray effects on MABL momentum distribution. The theoretical solutions were compared with model solutions neglecting wave-induced stress and/or spray stress. Surface waves strongly affected near-surface wind profiles and sea-surface drag coefficients at low to moderate wind speeds. Drag coefficients and near-surface wind speeds were lower for young than for old waves. At high wind speeds, ocean-spray droplets produced by wind-tearing breaking-wave crests affected the MABL strongly in comparison with surface waves, implying that wave age affects the MABL only negligibly. Low drag coefficients at high wind caused by ocean-spray production increased turbulent stress in the sea-spray generation layer, accelerating near-sea-surface wind. Comparing the analytical drag coefficient values with laboratory measurements and field observations indicated that surface waves and ocean spray significantly affect the MABL at different wind speeds and wave ages.

  4. 40 CFR 417.150 - Applicability; description of the manufacture of spray dried detergents subcategory.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... manufacture of spray dried detergents subcategory. 417.150 Section 417.150 Protection of Environment... POINT SOURCE CATEGORY Manufacture of Spray Dried Detergents Subcategory § 417.150 Applicability; description of the manufacture of spray dried detergents subcategory. The provisions of this subpart are...

  5. Quantitative Assessment of Spray Deposition with Water-Sensitive Paper

    USDA-ARS?s Scientific Manuscript database

    Spray droplets, discharged from the lower six nozzles of an airblast sprayer, were sampled on pairs of absorbent filter and water-sensitive papers at nine distances from sprayer. Spray deposition on filter targets were measured by fluorometry and spray distribution on WSP targets were assessed by t...

  6. Aerial application equipment for herbicidal drift reduction.

    Treesearch

    1976-01-01

    This publication provides silviculturists and managers of utility rights-of-way with a description and evaluation of available helicopter spray application equipment. Modified conventional equipment will reduce drift of sprays in normal carriers and apply various high-viscosity sprays. Specialized spray systems have found limited use in forestry; they are more commonly...

  7. Remotely controlled spray gun

    NASA Technical Reports Server (NTRS)

    Cunningham, William C. (Inventor)

    1987-01-01

    A remotely controlled spray gun is described in which a nozzle and orifice plate are held in precise axial alignment by an alignment member, which in turn is held in alignment with the general outlet of the spray gun by insert. By this arrangement, the precise repeatability of spray patterns is insured.

  8. Further Evaluation of Spray Characterization of Sprayers Typically Used in Vector Control

    DTIC Science & Technology

    2012-01-01

    E1260. Standard test method for determining liquid drop size characteristics in a spray using optical nonimaging light-scattering instru- ments...The time that the spray cloud was directed through the optical path of the laser varied between sprayers depending on the width of the spray plume

  9. Herbicidal drift control: aerial spray equipment, formulations, and supervision.

    Treesearch

    H. Gratkowski

    1974-01-01

    Public concern over environmental pollution requires increasingly sophisticated procedures when herbicides are used in silviculture. Many specialized aerial application systems and spray additives have been developed to reduce drift of herbicidal sprays. This publication provides forest-land managers with a brief description of these aerial spray systems and additives...

  10. PRN 90-3: Announcing the Formation of an Industry-Wide Spray Drift Task Force

    EPA Pesticide Factsheets

    A Spray Drift Task Force has been organized pursuant to provisions of FIFRA section 3 (c)(2)(B)(ii) to share the cost of developing a generic spray drift data base capable of satisfying spray drift data requirements for pesticide product registrations.

  11. 49 CFR 173.465 - Type A packaging tests.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ..., with contents, must be capable of withstanding the water spray, free drop, stacking and penetration... paragraph (b) of this section are met. (b) Water spray test. The water spray test must precede each test or test sequence prescribed in this section. The water spray test must simulate exposure to rainfall of...

  12. A new method for spray deposit assessment

    Treesearch

    Chester M. Himel; Leland Vaughn; Raymond P. Miskus; Arthur D. Moore

    1965-01-01

    Solid fluorescent particles suspended in a spray liquid are distributed in direct proportion to the size of the spray droplets. Use of solid fluorescent particles is the basis of a new method for visual recognition of the size and number of droplets impinging on target and nontarget portions of sprayed areas.

  13. Atomization from agricultural spray nozzles: Effects of air shear and tank mix adjuvants

    USDA-ARS?s Scientific Manuscript database

    Spray adjuvants can have a substantial impact on spray atomization from agricultural nozzles; however, this process is also affected by the nozzle type, operating pressure and, for aerial application, the airspeed of application. Different types of ground spray nozzle can dramatically affect the im...

  14. Effects of nozzle spray angle on droplet size and velocity

    USDA-ARS?s Scientific Manuscript database

    Spray applicators have many choices in selecting a spray nozzle to make an application of an agricultural product. They must balance flowrate, spray pressure, and nozzle type and setup to deliver their agrochemical in the right droplet size for their particular needs. Studies were conducted to det...

  15. Measuring droplet size of agriuclutral spray nozzles - Measurement distance and airspeed effects

    USDA-ARS?s Scientific Manuscript database

    With a number of new spray testing laboratories going into operation within the U.S. and each gearing up to measure spray atomization from agricultural spray nozzles using laser diffraction, establishing and following a set of scientific standard procedures is crucial to long term data generation an...

  16. Spray Distribution of Boomless Nozzles: The Boomjet 5880, Radiarc and Boom Buster

    Treesearch

    James H. Miller

    1990-01-01

    Abstract. The patterns of spray distribution are described for three boomless nozzlesthat arc commonly used, or have promise, for forestry applications: The BoomJet5880 cluster nozzle (Spraying Systems Co.), the Radiarc (Waldrum specialties ), and the Boom Buster (Evergreen Products). Spray distribution patterns were determined using regularly...

  17. Soil Seed Bank Responses to Postfire Herbicide and Native Seeding Treatments Designed to Control Bromus tectorum in a Pinyon–Juniper Woodland at Zion National Park, USA

    USGS Publications Warehouse

    Brooks, Matthew L.; Hondo Brisbin, graduate student; Andrea Thode, Associate Professor; Karen Weber, graduate student

    2013-01-01

    The continued threat of an invasive, annual brome (Bromus) species in the western United States has created the need for integrated approaches to postfire restoration. Additionally, the high germination rate, high seed production, and seed bank carryover of annual bromes points to the need to assay soil seed banks as part of monitoring programs. We sampled the soil seed bank to help assess the effectiveness of treatments utilizing the herbicide Plateau® (imazapic) and a perennial native seed mix to control annual Bromus species and enhance perennial native plant establishment following a wildfire in Zion National Park, Utah. This study is one of few that have monitored the effects of imazapic and native seeding on a soil seed bank community and the only one that we know of that has done so in a pinyon–juniper woodland. The study made use of untreated, replicated controls, which is not common for seed bank studies. One year posttreatment, Bromus was significantly reduced in plots sprayed with herbicide. By the second year posttreatment, the effects of imazapic were less evident and convergence with the controls was evident. Emergence of seeded species was low for the duration of the study. Dry conditions and possible interactions with imazapic probably contributed to the lack of emergence of seeded native species. The perennial grass sand dropseed outperformed the other species included in the seed mix. We also examined how the treatments affected the soil seed bank community as a whole. We found evidence that the herbicide was reducing several native annual forbs and one nonnative annual forb. However, overall effects on the community were not significant. The results of our study were similar to what others have found in that imazapic is effective in providing a short-term reduction in Bromus density, although it can impact emergence of nontarget species.

  18. A New Quantitative 3D Imaging Method for Characterizing Spray in the Near-field of Nozzle Exits

    DTIC Science & Technology

    2015-01-13

    measurements were performed on a flat-panel tabletop cone - beam CT system in the Radiology Department at Stanford University. The X-ray generator (CPI...quantitative measurement technique to examine the dense near-field region of sprays using X-ray computed tomography (CT). An optimized “spray CT system” was...Office P.O. Box 12211 Research Triangle Park, NC 27709-2211 X-ray CT, Spray, Hollow Cone Spray, Near Field REPORT DOCUMENTATION PAGE 11. SPONSOR

  19. Vacuum Plasma Spraying Replaces Electrodeposition

    NASA Technical Reports Server (NTRS)

    Holmes, Richard R.; Power, Chris; Burns, David H.; Daniel, Ron; Mckechnie, Timothy N.

    1992-01-01

    Vacuum plasma spraying used to fabricate large parts with complicated contours and inner structures, without uninspectable welds. Reduces time, and expense of fabrication. Wall of combustion chamber built up inside of outer nickel-alloy jacket by plasma spraying. Particles of metal sprayed partially melted in plasma gun and thrown at supersonic speed toward deposition surface. Vacuum plasma-spray produces stronger bond between the grooves and covering layer completing channels and wall of combustion chamber. In tests, bond withstood pressure of 20 kpsi, three times allowable limit by old method.

  20. Evaluation of Convergent Spray Technology(TM) Spray Process for Roof Coating Application

    NASA Technical Reports Server (NTRS)

    Scarpa, J.; Creighton, B.; Hall, T.; Hamlin, K.; Howard, T.

    1998-01-01

    The overall goal of this project was to demonstrate the feasibility of(CST) Convergent Spray Technology (Trademark) for the roofing industry. This was accomplished by producing an environmentally compliant coating utilization recycled materials, a CST(Trademark) spray process portable application cart, and hand-held applicator with a CST(Trademark) spray process nozzle. The project culminated with application of this coating to a nine hundred sixty square foot metal for NASA Marshall Space Flight Center (MSFC) in Huntsville, Alabama.

Top