Klibansky, David; Rothstein, Richard I
2012-09-01
The increasing complexity of intralumenal and emerging translumenal endoscopic procedures has created an opportunity to apply robotics in endoscopy. Computer-assisted or direct-drive robotic technology allows the triangulation of flexible tools through telemanipulation. The creation of new flexible operative platforms, along with other emerging technology such as nanobots and steerable capsules, can be transformational for endoscopic procedures. In this review, we cover some background information on the use of robotics in surgery and endoscopy, and review the emerging literature on platforms, capsules, and mini-robotic units. The development of techniques in advanced intralumenal endoscopy (endoscopic mucosal resection and endoscopic submucosal dissection) and translumenal endoscopic procedures (NOTES) has generated a number of novel platforms, flexible tools, and devices that can apply robotic principles to endoscopy. The development of a fully flexible endoscopic surgical toolkit will enable increasingly advanced procedures to be performed through natural orifices. The application of platforms and new flexible tools to the areas of advanced endoscopy and NOTES heralds the opportunity to employ useful robotic technology. Following the examples of the utility of robotics from the field of laparoscopic surgery, we can anticipate the emerging role of robotic technology in endoscopy.
Marcus, Hani J; Cundy, Thomas P; Hughes-Hallett, Archie; Yang, Guang-Zhong; Darzi, Ara; Nandi, Dipankar
2014-10-01
The literature reflects a resurgence of interest in endoscopic and keyhole endoscope-assisted neurosurgical approaches as alternatives to conventional microsurgical approaches in carefully selected cases. The aim of this study was to assess the technical challenges of neuroendoscopy, and the scope for technological innovations to overcome these barriers. All full members of the Society of British Neurosurgeons (SBNS) were electronically invited to participate in an online survey. The open-ended structured survey asked three questions; firstly, whether the surgeon presently utilises or has experience with endoscopic or endoscope-assisted approaches; secondly, what they consider to be the major technical barriers to adopting such approaches; and thirdly, what technological advances they foresee improving safety and efficacy in the field. Responses were subjected to a qualitative research method of multi-rater emergent theme analysis. Three clear themes emerged: 1) surgical approach and better integration with image-guidance systems (20%), 2) intra-operative visualisation and improvements in neuroendoscopy (49%), and 3) surgical manipulation and improvements in instruments (74%). The analysis of responses to our open-ended survey revealed that although opinion was varied three major themes could be identified. Emerging technological advances such as augmented reality, high-definition stereo-endoscopy, and robotic joint-wristed instruments may help overcome the technical difficulties associated with neuroendoscopic approaches. Results of this qualitative survey provide consensus amongst the technology end-user community such that unambiguous goals and priorities may be defined. Systems integrating these advances could improve the safety and efficacy of endoscopic and endoscope-assisted neurosurgical approaches.
Marcus, Hani J; Cundy, Thomas P; Hughes-Hallett, Archie; Yang, Guang-Zhong; Darzi, Ara; Nandi, Dipankar
2014-01-01
Introduction The literature reflects a resurgence of interest in endoscopic and keyhole endoscope-assisted neurosurgical approaches as alternatives to conventional microsurgical approaches in carefully selected cases. The aim of this study was to assess the technical challenges of neuroendoscopy, and the scope for technological innovations to overcome these barriers. Materials and Methods All full members of the Society of British Neurosurgeons (SBNS) were electronically invited to participate in an online survey. The open-ended structured survey asked three questions; firstly, whether the surgeon presently utilises or has experience with endoscopic or endoscope-assisted approaches; secondly, what they consider to be the major technical barriers to adopting such approaches; and thirdly, what technological advances they foresee improving safety and efficacy in the field. Responses were subjected to a qualitative research method of multi-rater emergent themes analysis. Results Three clear themes emerged: 1) surgical approach and better integration with image-guidance systems (20%), 2) intra-operative visualisation and improvements in neuroendoscopy (49%), and 3) surgical manipulation and improvements in instruments (74%). Discussion The analysis of responses to our open-ended survey revealed that although opinion was varied three major themes could be identified. Emerging technological advances such as augmented reality, high-definition stereo-endoscopy, and robotic joint-wristed instruments may help overcome the technical difficulties associated with neuroendoscopic approaches. Conclusions Results of this qualitative survey provide consensus amongst the technology end-user community such that unambiguous goals and priorities may be defined. Systems integrating these advances could improve the safety and efficacy of endoscopic and endoscope-assisted neurosurgical approaches. PMID:24533591
Advanced endoscopic imaging in gastric neoplasia and preneoplasia
Lee, Jonathan W J; Lim, Lee Guan; Yeoh, Khay Guan
2017-01-01
Conventional white light endoscopy remains the current standard in routine clinical practice for early detection of gastric cancer. However, it may not accurately diagnose preneoplastic gastric lesions. The technological advancements in the field of endoscopic imaging for gastric lesions are fast growing. This article reviews currently available advanced endoscopic imaging modalities, in particular chromoendoscopy, narrow band imaging and confocal laser endomicroscopy, and their corresponding evidence shown to improve diagnosis of preneoplastic gastric lesions. Raman spectrometry and polarimetry are also introduced as promising emerging technologies. PMID:28176895
An Update to Hepatobiliary Stents
Moy, Brian T.; Birk, John W.
2015-01-01
Endoscopic stent placement is a common primary management therapy for benign and malignant biliary strictures. However, continuous use of stents is limited by occlusion and migration. Stent technology has evolved significantly over the past two decades to reduce these problems. The purpose of this article is to review current guidelines in managing malignant and benign biliary obstructions, current endoscopic techniques for stent placement, and emerging stent technology. What began as a simple plastic stent technology has evolved significantly to include uncovered, partially covered, and fully covered self-expanding metal stents (SEMS) as well as magnetic, bioabsorbable, drug-eluting, and antireflux stents.1 PMID:26357636
NASA Technical Reports Server (NTRS)
Henriksen, Mina D.
1995-01-01
The research performed was a small portion of the patent to be submitted by Dr. Alan T. Pope entitled 'A Method of Providing Veridical Non-Invasive Endoscopic Feedback for Learning of Voluntary Control of Physiological Functioning'. The focus of this study is to incorporate the emerging technology of virtual reality with the forms of biofeedback already in existance producing a life-like, real-time model of the body's functioning without using invasive procedures, yet still producing the equivalent of a picture from an invasive endoscopic procedure in the region of interest. The portion of the project designated to me was to research and report as many possible uses for such technology as possible.
Peroral endoscopic myotomy: An emerging minimally invasive procedure for achalasia
Vigneswaran, Yalini; Ujiki, Michael B
2015-01-01
Peroral endoscopic myotomy (POEM) is an emerging minimally invasive procedure for the treatment of achalasia. Due to the improvements in endoscopic technology and techniques, this procedure allows for submucosal tunneling to safely endoscopically create a myotomy across the hypertensive lower esophageal sphincter. In the hands of skilled operators and experienced centers, the most common complications of this procedure are related to insufflation and accumulation of gas in the chest and abdominal cavities with relatively low risks of devastating complications such as perforation or delayed bleeding. Several centers worldwide have demonstrated the feasibility of this procedure in not only early achalasia but also other indications such as redo myotomy, sigmoid esophagus and spastic esophagus. Short-term outcomes have showed great clinical efficacy comparable to laparoscopic Heller myotomy (LHM). Concerns related to postoperative gastroesophageal reflux remain, however several groups have demonstrated comparable clinical and objective measures of reflux to LHM. Although long-term outcomes are necessary to better understand durability of the procedure, POEM appears to be a promising new procedure. PMID:26468336
Technological advances in robotic-assisted laparoscopic surgery.
Tan, Gerald Y; Goel, Raj K; Kaouk, Jihad H; Tewari, Ashutosh K
2009-05-01
In this article, the authors describe the evolution of urologic robotic systems and the current state-of-the-art features and existing limitations of the da Vinci S HD System (Intuitive Surgical, Inc.). They then review promising innovations in scaling down the footprint of robotic platforms, the early experience with mobile miniaturized in vivo robots, advances in endoscopic navigation systems using augmented reality technologies and tracking devices, the emergence of technologies for robotic natural orifice transluminal endoscopic surgery and single-port surgery, advances in flexible robotics and haptics, the development of new virtual reality simulator training platforms compatible with the existing da Vinci system, and recent experiences with remote robotic surgery and telestration.
Natural orifice transluminal endoscopic surgery for intra-abdominal emergency conditions.
Bingener, J; Ibrahim-zada, I
2014-01-01
Patient benefits from natural orifice transluminal endoscopic surgery (NOTES) are of interest in acute-care surgery. This review provides an overview of the historical development of NOTES procedures, and addresses their current uses and limitations for intra-abdominal emergency conditions. A PubMed search was carried out for articles describing NOTES approaches for appendicectomy, percutaneous gastrostomy, hollow viscus perforation and pancreatic necrosectomy. Pertinent articles were reviewed and data on available outcomes synthesized. Emergency conditions in surgery tax the patient's cardiovascular and respiratory systems, and fluid and electrolyte balance. The operative intervention itself leads to an inflammatory response and blood loss, thus adding to the physiological stress. NOTES provides a minimally invasive alternative access to the peritoneal cavity, avoiding abdominal wall incisions. A clear advantage to the patient is evident with the implementation of an endoscopic approach to deal with inadvertently displaced percutaneous endoscopic gastrostomy tubes and perforated gastroduodenal ulcer. The NOTES approach appears less invasive for patients with infected pancreatic necrosis, in whom it allows surgical debridement and avoidance of open necrosectomy. Transvaginal appendicectomy is the second most frequently performed NOTES procedure after cholecystectomy. The NOTES concept has provided a change in perspective for intramural and transmural endoscopic approaches to iatrogenic perforations during endoscopy. NOTES approaches have been implemented in clinical practice over the past decade. Selected techniques offer reduced invasiveness for patients with intra-abdominal emergencies, and may improve outcomes. Steady future development and adoption of NOTES are likely to follow as technology improves and surgeons become comfortable with the approaches. © 2013 BJS Society Ltd. Published by John Wiley & Sons Ltd.
Comparison of methods for quantitative evaluation of endoscopic distortion
NASA Astrophysics Data System (ADS)
Wang, Quanzeng; Castro, Kurt; Desai, Viraj N.; Cheng, Wei-Chung; Pfefer, Joshua
2015-03-01
Endoscopy is a well-established paradigm in medical imaging, and emerging endoscopic technologies such as high resolution, capsule and disposable endoscopes promise significant improvements in effectiveness, as well as patient safety and acceptance of endoscopy. However, the field lacks practical standardized test methods to evaluate key optical performance characteristics (OPCs), in particular the geometric distortion caused by fisheye lens effects in clinical endoscopic systems. As a result, it has been difficult to evaluate an endoscope's image quality or assess its changes over time. The goal of this work was to identify optimal techniques for objective, quantitative characterization of distortion that are effective and not burdensome. Specifically, distortion measurements from a commercially available distortion evaluation/correction software package were compared with a custom algorithm based on a local magnification (ML) approach. Measurements were performed using a clinical gastroscope to image square grid targets. Recorded images were analyzed with the ML approach and the commercial software where the results were used to obtain corrected images. Corrected images based on the ML approach and the software were compared. The study showed that the ML method could assess distortion patterns more accurately than the commercial software. Overall, the development of standardized test methods for characterizing distortion and other OPCs will facilitate development, clinical translation, manufacturing quality and assurance of performance during clinical use of endoscopic technologies.
Submucosal tunnel endoscopy: Peroral endoscopic myotomy and peroral endoscopic tumor resection
Eleftheriadis, Nikolas; Inoue, Haruhiro; Ikeda, Haruo; Onimaru, Manabu; Maselli, Roberta; Santi, Grace
2016-01-01
Peroral endoscopic myotomy (POEM) is an innovative, minimally invasive, endoscopic treatment for esophageal achalasia and other esophageal motility disorders, emerged from the natural orifice transluminal endoscopic surgery procedures, and since the first human case performed by Inoue in 2008, showed exciting results in international level, with more than 4000 cases globally up to now. POEM showed superior characteristics than the standard 100-year-old surgical or laparoscopic Heller myotomy (LHM), not only for all types of esophageal achalasia [classical (I), vigorous (II), spastic (III), Chicago Classification], but also for advanced sigmoid type achalasia (S1 and S2), failed LHM, or other esophageal motility disorders (diffuse esophageal spasm, nutcracker esophagus or Jackhammer esophagus). POEM starts with a mucosal incision, followed by submucosal tunnel creation crossing the esophagogastric junction (EGJ) and myotomy. Finally the mucosal entry is closed with endoscopic clip placement. POEM permitted relatively free choice of myotomy length and localization. Although it is technically demanding procedure, POEM can be performed safely and achieves very good control of dysphagia and chest pain. Gastroesophageal reflux is the most common troublesome side effect, and is well controllable with proton pump inhibitors. Furthermore, POEM opened the era of submucosal tunnel endoscopy, with many other applications. Based on the same principles with POEM, in combination with new technological developments, such as endoscopic suturing, peroral endoscopic tumor resection (POET), is safely and effectively applied for challenging submucosal esophageal, EGJ and gastric cardia tumors (submucosal tumors), emerged from muscularis propria. POET showed up to know promising results, however, it is restricted to specialized centers. The present article reviews the recent data of POEM and POET and discussed controversial issues that need further study and future perspectives. PMID:26839649
Son, Jaebum; Cho, Chang Nho; Kim, Kwang Gi; Chang, Tae Young; Jung, Hyunchul; Kim, Sung Chun; Kim, Min-Tae; Yang, Nari; Kim, Tae-Yun; Sohn, Dae Kyung
2015-06-01
Natural orifice transluminal endoscopic surgery (NOTES) is an emerging surgical technique. We aimed to design, create, and evaluate a new semi-automatic snake robot for NOTES. The snake robot employs the characteristics of both a manual endoscope and a multi-segment snake robot. This robot is inserted and retracted manually, like a classical endoscope, while its shape is controlled using embedded robot technology. The feasibility of a prototype robot for NOTES was evaluated in animals and human cadavers. The transverse stiffness and maneuverability of the snake robot appeared satisfactory. It could be advanced through the anus as far as the peritoneal cavity without any injury to adjacent organs. Preclinical tests showed that the device could navigate the peritoneal cavity. The snake robot has advantages of high transverse force and intuitive control. This new robot may be clinically superior to conventional tools for transanal NOTES.
Recent advances in targeted endoscopic imaging: Early detection of gastrointestinal neoplasms
Kwon, Yong-Soo; Cho, Young-Seok; Yoon, Tae-Jong; Kim, Ho-Shik; Choi, Myung-Gyu
2012-01-01
Molecular imaging has emerged as a new discipline in gastrointestinal endoscopy. This technology encompasses modalities that can visualize disease-specific morphological or functional tissue changes based on the molecular signature of individual cells. Molecular imaging has several advantages including minimal damage to tissues, repetitive visualization, and utility for conducting quantitative analyses. Advancements in basic science coupled with endoscopy have made early detection of gastrointestinal cancer possible. Molecular imaging during gastrointestinal endoscopy requires the development of safe biomarkers and exogenous probes to detect molecular changes in cells with high specificity anda high signal-to-background ratio. Additionally, a high-resolution endoscope with an accurate wide-field viewing capability must be developed. Targeted endoscopic imaging is expected to improve early diagnosis and individual therapy of gastrointestinal cancer. PMID:22442742
New Developments in Robotics and Single-site Gynecologic Surgery.
Matthews, Catherine A
2017-06-01
Within the last 10 years there have been significant advances in minimal-access surgery. Although no emerging technology has demonstrated improved outcomes or fewer complications than standard laparoscopy, the introduction of the robotic surgical platform has significantly lowered abdominal hysterectomy rates. While operative time and cost were higher in robotic-assisted procedures when the technology was first introduced, newer studies demonstrate equivalent or improved robotic surgical efficiency with increased experience. Single-port hysterectomy has not improved postoperative pain or subjective cosmetic results. Emerging platforms with flexible, articulating instruments may increase the uptake of single-port procedures including natural orifice transluminal endoscopic cases.
Endoscopic features of gastro-intestinal lymphomas: From diagnosis to follow-up
Vetro, Calogero; Romano, Alessandra; Amico, Irene; Conticello, Concetta; Motta, Giovanna; Figuera, Amalia; Chiarenza, Annalisa; Di Raimondo, Cosimo; Giulietti, Giorgio; Bonanno, Giacomo; Palumbo, Giuseppe Alberto; Di Raimondo, Francesco
2014-01-01
Many progresses have been done in the management of gastrointestinal (GI) lymphomas during last decades, especially after the discovery of Helicobacter pylori-dependent lymphoma development. The stepwise implementation of new endoscopic techniques, by means of echoendoscopy or double-balloon enteroscopy, enabled us to more precisely describe the endoscopic features of GI lymphomas with substantial contribution in patient management and in tailoring the treatment strategy with organ preserving approaches. In this review, we describe the recent progresses in GI lymphoma management from disease diagnosis to follow-up with a specific focus on the endoscopic presentation according to the involved site and the lymphoma subtype. Additionally, new or emerging endoscopic technologies that have an impact on the management of gastrointestinal lymphomas are reported. We here discuss the two most common subtypes of GI lymphomas: the mucosa-associated lymphoid tissue and the diffuse large B cell lymphoma. A general outline on the state-of-the-art of the disease and on the role of endoscopy in both diagnosis and follow-up will be performed. PMID:25278693
Accidental hijab pin ingestion in Muslim women: an emerging endoscopic emergency?
Goh, Jason; Patel, Neeral; Boulton, Ralph
2014-01-03
Ingested foreign body is an infrequent indication for emergency endoscopy in the adult gastroenterology practice. We describe the clinical features and endoscopic management of the first four cases of accidental ingestion of hijab pins by Muslim women in our unit, all presenting within a 12-month period. The pins were all successfully retrieved without any complications. In this report, we review published guidelines and the current literature, as well as discussing the approach (conservative vs proactive endoscopic retrieval) and timing of endoscopic treatment. The Muslim community may need to be alerted to the potential health hazard of hijab pins.
Accidental hijab pin ingestion in Muslim women: an emerging endoscopic emergency?
Goh, Jason; Patel, Neeral; Boulton, Ralph
2014-01-01
Ingested foreign body is an infrequent indication for emergency endoscopy in the adult gastroenterology practice. We describe the clinical features and endoscopic management of the first four cases of accidental ingestion of hijab pins by Muslim women in our unit, all presenting within a 12-month period. The pins were all successfully retrieved without any complications. In this report, we review published guidelines and the current literature, as well as discussing the approach (conservative vs proactive endoscopic retrieval) and timing of endoscopic treatment. The Muslim community may need to be alerted to the potential health hazard of hijab pins. PMID:24390968
Review of emerging surgical robotic technology.
Peters, Brian S; Armijo, Priscila R; Krause, Crystal; Choudhury, Songita A; Oleynikov, Dmitry
2018-04-01
The use of laparoscopic and robotic procedures has increased in general surgery. Minimally invasive robotic surgery has made tremendous progress in a relatively short period of time, realizing improvements for both the patient and surgeon. This has led to an increase in the use and development of robotic devices and platforms for general surgery. The purpose of this review is to explore current and emerging surgical robotic technologies in a growing and dynamic environment of research and development. This review explores medical and surgical robotic endoscopic surgery and peripheral technologies currently available or in development. The devices discussed here are specific to general surgery, including laparoscopy, colonoscopy, esophagogastroduodenoscopy, and thoracoscopy. Benefits and limitations of each technology were identified and applicable future directions were described. A number of FDA-approved devices and platforms for robotic surgery were reviewed, including the da Vinci Surgical System, Sensei X Robotic Catheter System, FreeHand 1.2, invendoscopy E200 system, Flex® Robotic System, Senhance, ARES, the Single-Port Instrument Delivery Extended Research (SPIDER), and the NeoGuide Colonoscope. Additionally, platforms were reviewed which have not yet obtained FDA approval including MiroSurge, ViaCath System, SPORT™ Surgical System, SurgiBot, Versius Robotic System, Master and Slave Transluminal Endoscopic Robot, Verb Surgical, Miniature In Vivo Robot, and the Einstein Surgical Robot. The use and demand for robotic medical and surgical platforms is increasing and new technologies are continually being developed. New technologies are increasingly implemented to improve on the capabilities of previously established systems. Future studies are needed to further evaluate the strengths and weaknesses of each robotic surgical device and platform in the operating suite.
Development of terahertz endoscopic system for cancer detection
NASA Astrophysics Data System (ADS)
Doradla, Pallavi; Alavi, Karim; Joseph, Cecil S.; Giles, Robert H.
2016-02-01
Terahertz (THz) imaging is emerging as a robust platform for a myriad of applications in the fields of security, health, astronomy and material science. The terahertz regime with wavelengths spanning from microns to millimeters is a potentially safe and noninvasive medical imaging modality for detecting cancers. Endoscopic imaging systems provide high flexibility in examining the interior surfaces of an organ or tissue. Researchers have been working on the development of THz endoscopes with photoconductive antennas, which necessarily operate under high voltage, and require at least two channels to measure the reflected signal from the specimen. This manuscript provides the design and imperative steps involved in the development of a single-channel terahertz endoscopic system. The continuous-wave terahertz imaging system utilizes a single flexible terahertz waveguide channel to transmit and collect the back reflected intrinsic terahertz signal from the sample and is capable of operation in both transmission and reflection modalities. To determine the feasibility of using a terahertz endoscope for cancer detection, the co- and cross-polarized terahertz remittance from human colonic tissue specimens were collected at 584 GHz frequency. The two dimensional terahertz images obtained using polarization specific detection exhibited intrinsic contrast between cancerous and normal regions of fresh colorectal tissue. The level of contrast observed using endoscopic imaging correlates well with the contrast levels observed in the free space ex vivo terahertz reflectance studies of human colonic tissue. The prototype device developed in this study represents a significant step towards clinical endoscopic application of THz technology for in vivo colon cancer screening.
Fluoroscopy-Guided Endoscopic Removal of Foreign Bodies.
Kim, Junhwan; Ahn, Ji Yong; So, Seol; Lee, Mingee; Oh, Kyunghwan; Jung, Hwoon-Yong
2017-03-01
In most cases of ingested foreign bodies, endoscopy is the first treatment of choice. Moreover, emergency endoscopic removal is required for sharp and pointed foreign bodies such as animal or fish bones, food boluses, and button batteries due to the increased risks of perforation, obstruction, and bleeding. Here, we presented two cases that needed emergency endoscopic removal of foreign bodies without sufficient fasting time. Foreign bodies could not be visualized by endoscopy due to food residue; therefore, fluoroscopic imaging was utilized for endoscopic removal of foreign bodies in both cases.
Ultrahigh-resolution endoscopic optical coherence tomography
NASA Astrophysics Data System (ADS)
Chen, Yu; Herz, Paul R.; Hsiung, Pei-Lin; Aguirre, Aaron D.; Mashimo, Hiroshi; Desai, Saleem; Pedrosa, Macos; Koski, Amanda; Schmitt, Joseph M.; Fujimoto, James G.
2005-01-01
Early detection of gastrointestinal cancer is essential for the patient treatment and medical care. Endoscopically guided biopsy is currently the gold standard for the diagnosis of early esophageal cancer, but can suffer from high false negative rates due to sampling errors. Optical coherence tomography (OCT) is an emerging medical imaging technology which can generate high resolution, cross-sectional images of tissue in situ and in real time, without the removal of tissue specimen. Although endoscopic OCT has been used successfully to identify certain pathologies in the gastrointestinal tract, the resolution of current endoscopic OCT systems has been limited to 10 - 15 m for clinical procedures. In this study, in vivo imaging of the gastrointestinal tract is demonstrated at a three-fold higher resolution (< 5 m), using a portable, broadband, Cr4+:Forsterite laser as the optical light source. Images acquired from the esophagus, gastro-esophageal junction and colon on animal model display tissue microstructures and architectural details at high resolution, and the features observed in the OCT images are well-matched with histology. The clinical feasibility study is conducted through delivering OCT imaging catheter using standard endoscope. OCT images of normal esophagus, Barrett's esophagus, and esophageal cancers are demonstrated with distinct features. The ability of high resolution endoscopic OCT to image tissue morphology at an unprecedented resolution in vivo would facilitate the development of OCT as a potential imaging modality for early detection of neoplastic changes.
Future of uniportal video-assisted thoracoscopic surgery-emerging technology.
Li, Zheng; Ng, Calvin S H
2016-03-01
Uniportal VATS poses unique difficulties to the surgeon, mainly as a consequence of operating through a small single incision. The instruments in uniportal VATS have limited movement through the small incision. In addition, the approach to the surgical operating site is unidirectional, which may restrict vision and retraction, and unavoidably suffers from instrument fencing. Recent thoracoscopic technology in the form of a wide variable angled lens has to some extent improved these shortcomings. The development of an extendable flexible thoracoscope and wireless steerable endoscope (WSE) systems can further improve the visualization for surgery and reduce or even remove fencing between endoscope and instruments. New single incision access platforms both derived from Natural orifice transluminal endoscopic surgery (NOTES) and robotic surgery approaches are on the horizon. These may allow uniportal VATS to be performed through an even smaller ultra-minimally invasive incision, with improved vision, more freedom of movement of the instruments and greater precision. However, a number of problems remain to be resolved, including provision of a stable platform and payload, applied force limitations and equipment sterilization. Advances in uniportal VATS major lung resection techniques have not only challenged the surgeon to acquire new skills and knowledge, but at the same time have rekindled the collaborative spirit between industry and clinician in developing novel equipment and technology to push the boundaries of minimally invasive surgery. These technological improvements and innovations may improve operating efficiency and safety during uniportal VATS surgery.
Mistry, N; Coulson, C; George, A
2017-11-01
Digital and mobile device technology in healthcare is a growing market. The introduction of the endoscope-i, the world's first endoscopic mobile imaging system, allows the acquisition of high definition images of the ear, nose and throat (ENT). The system combines the e-i Pro camera app with a bespoke engineered endoscope-i adaptor which fits securely onto the iPhone or iPod touch. Endoscopic examination forms a salient aspect of the ENT work-up. The endoscope-i therefore provides a mobile and compact alternative to the existing bulky endoscopic systems currently in use which often restrict the clinician to the clinic setting. Areas covered: This article gives a detailed overview of the endoscope-i system together with its applications. A review and comparison of alternative devices on the market offering smartphone adapted endoscopic viewing systems is also presented. Expert commentary: The endoscope-i fulfils unmet needs by providing a compact, highly portable, simple to use endoscopic viewing system which is cost-effective and which makes use of smartphone technology most clinicians have in their pocket. The system allows real-time feedback to the patient and has the potential to transform the way that healthcare is delivered in ENT as well as having applications further afield.
Zhao, Hong; Cheng, Jilin; Xu, Yahong; Lu, Cuili; Huang, Shaoping; Fan, Zhenyu; Shi, Yuxin
2014-01-01
Sclerotherapy and endoscopic esophageal variceal ligation (EVL) are commonly used to treat and prevent variceal bleeding. As of today, there has been no report on an unexpected incarceration of a varix hooked on with the bands from the endoscopic EVL device. We recently experienced this emergency while using the 7-band ring endoscopic EVL device (Boston Scientific Corp., Boston, MA) for prophylaxis of variceal bleeding. In this case, the varix body itself was accidently incarcerated in the crevice of the esophageal endoscope after highly negative pressure of absorption was applied on the endoscope. In this situation, using force to take out the gastroscope was not an option as it would tear the vein and cause massive hemorrhage. We were managed to ligate the varix with rubber bands while releasing the incarceration. We observed that ligation of the varix at the same position using all seven ligation bands resulted in disappearance of the targeted varix. The surrounding esophageal mucosa became smooth after the treatment. PMID:25550983
Spectral-domain optical coherence tomography for endoscopic imaging
NASA Astrophysics Data System (ADS)
Chen, Xiaodong; Li, Qiao; Li, Wanhui; Wang, Yi; Yu, Daoyin
2007-02-01
Optical coherence tomography (OCT) is an emerging cross-sectional imaging technology. It uses broadband light sources to achieve axial image resolutions on the few micron scale. OCT is widely applied to medical imaging, it can get cross-sectional image of bio-tissue (transparent and turbid) with non-invasion and non-touch. In this paper, the principle of OCT is presented and the crucial parameters of the system are discussed in theory. With analysis of different methods and medical endoscopic system's feature, a design which combines the spectral domain OCT (SDOCT) technique and endoscopy is put forward. SDOCT provides direct access to the spectrum of the optical signal. It is shown to provide higher imaging speed when compared to time domain OCT. At the meantime, a novel OCT probe which uses advanced micromotor to drive reflecting prism is designed according to alimentary tract endoscopic feature. A simple optical coherence tomography system has been developed based on a fiber-based Michelson interferometer and spectrometer. An experiment which uses motor to drive prism to realize rotating imaging is done. Images obtained with this spectral interferometer are presented. The results verify the feasibility of endoscopic optical coherence tomography system with rotating scan.
Rare gastrointestinal lymphomas: The endoscopic investigation
Vetro, Calogero; Bonanno, Giacomo; Giulietti, Giorgio; Romano, Alessandra; Conticello, Concetta; Chiarenza, Annalisa; Spina, Paolo; Coppolino, Francesco; Cunsolo, Rosario; Raimondo, Francesco Di
2015-01-01
Gastrointestinal lymphomas represent up to 10% of gastrointestinal malignancies and about one third of non-Hodgkin lymphomas. The most prominent histologies are mucosa-associated lymphoid tissue lymphoma and diffuse large B-cell lymphoma. However, the gastrointestinal tract can be the site of rarer lymphoma subtypes as a primary or secondary localization. Due to their rarity and the multifaceted histology, an endoscopic classification has not been validated yet. This review aims to analyze the endoscopic presentation of rare gastrointestinal lymphomas from disease diagnosis to follow-up, according to the involved site and lymphoma subtype. Existing, new and emerging endoscopic technologies have been examined. In particular, we investigated the diagnostic, prognostic and follow-up endoscopic features of T-cell and natural killer lymphomas, lymphomatous polyposis and mantle cell lymphoma, follicular lymphoma, plasma cell related disease, gastrointestinal lymphomas in immunodeficiency and Hodgkin’s lymphoma of the gastrointestinal tract. Contrarily to more frequent gastrointestinal lymphomas, data about rare lymphomas are mostly extracted from case series and case reports. Due to the data paucity, a synergism between gastroenterologists and hematologists is required in order to better manage the disease. Indeed, clinical and prognostic features are different from nodal and extranodal or the bone marrow (in case of plasma cell disease) counterpart. Therefore, the approach should be based on the knowledge of the peculiar behavior and natural history of disease. PMID:26265987
Robotics and systems technology for advanced endoscopic procedures: experiences in general surgery.
Schurr, M O; Arezzo, A; Buess, G F
1999-11-01
The advent of endoscopic techniques changed surgery in many regards. This paper intends to describe an overview about technologies to facilitate endoscopic surgery. The systems described have been developed for the use in general surgery, but an easy application also in the field of cardiac surgery seems realistic. The introduction of system technology and robotic technology enables today to design a highly ergonomic solo-surgery platform. To relief the surgeon from fatigue we developed a new chair dedicated to the functional needs of endoscopic surgery. The foot pedals for high frequency, suction and irrigation are integrated into the basis of the chair. The chair is driven by electric motors controlled with an additional foot pedal joystick to achieve the desired position in the OR. A major enhancement for endoscopic technology is the introduction of robotic technology to design assisting devices for solo-surgery and manipulators for microsurgical instrumentation. A further step in the employment of robotic technology is the design of 'master-slave manipulators' to provide the surgeon with additional degrees of freedom of instrumentation. In 1996 a first prototype of an endoscopic manipulator system. named ARTEMIS, could be used in experimental applications. The system consists of a user station (master) and an instrument station (slave). The surgeon sits at a console which integrates endoscopic monitors, communication facilities and two master devices to control the two slave arms which are mounted to the operating table. Clinical use of the system, however, will require further development in the area of slave mechanics and the control system. Finally the implementation of telecommunication technology in combination with robotic instruments will open new frontiers, such as teleconsulting, teleassistance and telemanipulation.
Endoscopic optical coherence tomography: technologies and clinical applications [Invited
Gora, Michalina J.; Suter, Melissa J.; Tearney, Guillermo J.; Li, Xingde
2017-01-01
In this paper, we review the current state of technology development and clinical applications of endoscopic optical coherence tomography (OCT). Key design and engineering considerations are discussed for most OCT endoscopes, including side-viewing and forward-viewing probes, along with different scanning mechanisms (proximal-scanning versus distal-scanning). Multi-modal endoscopes that integrate OCT with other imaging modalities are also discussed. The review of clinical applications of endoscopic OCT focuses heavily on diagnosis of diseases and guidance of interventions. Representative applications in several organ systems are presented, such as in the cardiovascular, digestive, respiratory, and reproductive systems. A brief outlook of the field of endoscopic OCT is also discussed. PMID:28663882
Emerging Technologies for the Diagnosis of Perihilar Cholangiocarcinoma.
Rizvi, Sumera; Eaton, John; Yang, Ju Dong; Chandrasekhara, Vinay; Gores, Gregory J
2018-05-01
The diagnosis of malignant biliary strictures remains problematic, especially in the perihilar region and in primary sclerosing cholangitis (PSC). Conventional cytology obtained during endoscopic retrograde cholangiography (ERC)-guided brushings of biliary strictures is suboptimal due to limited sensitivity, albeit it remains the gold standard with a high specificity. Emerging technologies are being developed and validated to address this pressing unmet patient need. Such technologies include enhanced visualization of the biliary tree by cholangioscopy, intraductal ultrasound, and confocal laser endomicroscopy. Conventional cytology can be aided by employing complementary and advanced cytologic techniques such as fluorescent in situ hybridization (FISH), and this technique should be widely adapted. Interrogation of bile and serum by examining extracellular vesicle number and cargo, and exploiting next-generation sequencing and proteomic technologies, is also being explored. Examination of circulating cell-free deoxyribonucleic acid (cfDNA) for differentially methylated regions is a promising test which is being rigorously validated. The special expertise required for these analyses has to date hampered their validation and adaptation. Herein, we will review these emerging technologies to inform the reader of the progress made and encourage further studies, as well as adaptation of validated approaches. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
The role of surgeons in identifying emerging technologies for health technology assessment.
Stafinski, Tania; Topfer, Leigh-Ann; Zakariasen, Ken; Menon, Devidas
2010-04-01
Health technology assessment (HTA) is a tool intended to help policy-makers decide which technologies to fund. However, given the proliferation of new technologies, it is not possible to undertake an HTA of each one before it becomes funded. Consequently, "horizon-scanning" processes have been developed to identify emerging technologies that are likely to have a substantial impact on clinical practice. Although the importance of physicians in the adoption of new technologies is well recognized, their role in horizon scanning in Canada has been limited. The purpose of this project was to pilot an approach to engage physicians, specifically surgeons, in provincial horizon-scanning activities. We invited 18 surgeons from Alberta's 2 medical schools to a horizon-scanning workshop to solicit their views on emerging technologies expected to impact surgical practice within the next 5 years and/or the importance of different attributes or characteristics of new technologies. Surgeons, regardless of specialty, identified developments designed to enhance existing minimally invasive surgical techniques, such as endoscopic, robotic and image-guided surgery. Several nonsurgical areas, including molecular genetics and nano technology, were also identified. Of the 13 technology attributes discussed, safety or risk, effectiveness and feasibility were rated as most important. Lastly, participating surgeons expressed an interest in becoming further involved in local HTA initiatives. Surgeons, as adopters and users of health technologies, represent an important and accessible information source for identifying emerging technologies for HTA. A more formal, ongoing relationship between the government, HTA and surgeons may help to optimize the use of HTA resources.
Senior, Brent A
2008-01-01
Endoscopic skull base surgery has undergone rapid advancement in the past decade moving from pituitary surgery to suprasellar lesions and now to a myriad of lesions extending from the cribriform plate to C2 and laterally out to the infratemporal fossa and petrous apex. Evolution of several technological advances as well as advances in understanding of endoscopic anatomy and the development of surgical techniques both in resection and reconstruction have fostered this capability. Management of benign disease via endoscopic methods is largely accepted now but more data is needed before the controversy on the role of endoscopic management of malignant disease is decided. Continued advances in surgical technique, navigation systems, endoscopic imaging technology, and robotics assure continued brisk evolution in this expanding field. PMID:19434274
The role of surgeons in identifying emerging technologies for health technology assessment
Stafinski, Tania; Topfer, Leigh-Ann; Zakariasen, Ken; Menon, Devidas
2010-01-01
Background Health technology assessment (HTA) is a tool intended to help policy-makers decide which technologies to fund. However, given the proliferation of new technologies, it is not possible to undertake an HTA of each one before it becomes funded. Consequently, “horizon-scanning” processes have been developed to identify emerging technologies that are likely to have a substantial impact on clinical practice. Although the importance of physicians in the adoption of new technologies is well recognized, their role in horizon scanning in Canada has been limited. The purpose of this project was to pilot an approach to engage physicians, specifically surgeons, in provincial horizon-scanning activities. Methods We invited 18 surgeons from Alberta’s 2 medical schools to a horizon-scanning workshop to solicit their views on emerging technologies expected to impact surgical practice within the next 5 years and/or the importance of different attributes or characteristics of new technologies. Results Surgeons, regardless of specialty, identified developments designed to enhance existing minimally invasive surgical techniques, such as endoscopic, robotic and image-guided surgery. Several nonsurgical areas, including molecular genetics and nanotechnology, were also identified. Of the 13 technology attributes discussed, safety or risk, effectiveness and feasibility were rated as most important. Lastly, participating surgeons expressed an interest in becoming further involved in local HTA initiatives. Conclusion Surgeons, as adopters and users of health technologies, represent an important and accessible information source for identifying emerging technologies for HTA. A more formal, ongoing relationship between the government, HTA and surgeons may help to optimize the use of HTA resources. PMID:20334740
East, James E; Vleugels, Jasper L; Roelandt, Philip; Bhandari, Pradeep; Bisschops, Raf; Dekker, Evelien; Hassan, Cesare; Horgan, Gareth; Kiesslich, Ralf; Longcroft-Wheaton, Gaius; Wilson, Ana; Dumonceau, Jean-Marc
2016-11-01
Background and aim: This technical review is an official statement of the European Society of Gastrointestinal Endoscopy (ESGE). It addresses the utilization of advanced endoscopic imaging in gastrointestinal (GI) endoscopy. Methods: This technical review is based on a systematic literature search to evaluate the evidence supporting the use of advanced endoscopic imaging throughout the GI tract. Technologies considered include narrowed-spectrum endoscopy (narrow band imaging [NBI]; flexible spectral imaging color enhancement [FICE]; i-Scan digital contrast [I-SCAN]), autofluorescence imaging (AFI), and confocal laser endomicroscopy (CLE). The Grading of Recommendations Assessment, Development and Evaluation (GRADE) system was adopted to define the strength of recommendation and the quality of evidence. Main recommendations: 1. We suggest advanced endoscopic imaging technologies improve mucosal visualization and enhance fine structural and microvascular detail. Expert endoscopic diagnosis may be improved by advanced imaging, but as yet in community-based practice no technology has been shown consistently to be diagnostically superior to current practice with high definition white light. (Low quality evidence.) 2. We recommend the use of validated classification systems to support the use of optical diagnosis with advanced endoscopic imaging in the upper and lower GI tracts (strong recommendation, moderate quality evidence). 3. We suggest that training improves performance in the use of advanced endoscopic imaging techniques and that it is a prerequisite for use in clinical practice. A learning curve exists and training alone does not guarantee sustained high performances in clinical practice. (Weak recommendation, low quality evidence.) Conclusion: Advanced endoscopic imaging can improve mucosal visualization and endoscopic diagnosis; however it requires training and the use of validated classification systems. © Georg Thieme Verlag KG Stuttgart · New York.
Stomach Dysfunction in Diabetes Mellitus: Emerging Technology and Pharmacology
Szarka, Lawrence A.; Camilleri, Michael
2010-01-01
Gastroparesis and other types of gastric dysfunction result in substantial morbidity in diabetes patients. The pathophysiology of these disorders is incompletely understood. This article reviews techniques applicable to the assessment of gastric function in diabetes patients, including the measurement of emptying, accommodation, and contractility. Available treatment options are also reviewed, including novel yet unapproved serotonin 5-HT4 agonist pharmacological treatments, as well as the role of endoscopic, surgical, and device treatments of gastroparesis. PMID:20167183
Honda, Hirokazu; Ikeya, Takashi; Kashiwagi, Erika; Okada, Shuichi; Fukuda, Katsuyuki
2017-01-01
Gastric bezoars are rare and are usually found incidentally. They can sometimes cause severe complications, including gastric outlet obstruction (GOO) or gastric pneumatosis (GP). In cases of bezoars with GP, the optimal treatment strategy has not yet been defined. We report the case of an 89-year-old man with a history of type 2 diabetes mellitus and hypertension who presented to our emergency room with a 2-day history of upper abdominal pain, nausea, and vomiting. Physical examination revealed no rebound tenderness or guarding, and laboratory values revealed no elevation of the serum lactate level. A computed tomography scan of the abdomen showed a dilated stomach with significant fluid collection, GOO, and GP due to a 42 × 40 mm mass composed of fat and air densities. Emergency esophagogastroduodenoscopy revealed two gastric bezoars, one of which was incarcerated in the pyloric region. We used various endoscopic devices to successfully break and remove the bezoars. We used endoscopic forceps and a water jet followed by an endoscopic snare to cut the bezoars into several pieces and remove them with an endoscopic net. Follow-up endoscopy confirmed that the gastric bezoar had been completely removed. As seen in this case, endoscopic treatment may be a safe and viable option for the extraction of gastric bezoars presenting with GOO and GP. PMID:29430223
Honda, Hirokazu; Ikeya, Takashi; Kashiwagi, Erika; Okada, Shuichi; Fukuda, Katsuyuki
2017-01-01
Gastric bezoars are rare and are usually found incidentally. They can sometimes cause severe complications, including gastric outlet obstruction (GOO) or gastric pneumatosis (GP). In cases of bezoars with GP, the optimal treatment strategy has not yet been defined. We report the case of an 89-year-old man with a history of type 2 diabetes mellitus and hypertension who presented to our emergency room with a 2-day history of upper abdominal pain, nausea, and vomiting. Physical examination revealed no rebound tenderness or guarding, and laboratory values revealed no elevation of the serum lactate level. A computed tomography scan of the abdomen showed a dilated stomach with significant fluid collection, GOO, and GP due to a 42 × 40 mm mass composed of fat and air densities. Emergency esophagogastroduodenoscopy revealed two gastric bezoars, one of which was incarcerated in the pyloric region. We used various endoscopic devices to successfully break and remove the bezoars. We used endoscopic forceps and a water jet followed by an endoscopic snare to cut the bezoars into several pieces and remove them with an endoscopic net. Follow-up endoscopy confirmed that the gastric bezoar had been completely removed. As seen in this case, endoscopic treatment may be a safe and viable option for the extraction of gastric bezoars presenting with GOO and GP.
Sung, Joseph Jy; Chiu, Philip Cy; Chan, Francis K L; Lau, James Yw; Goh, Khean-Lee; Ho, Lawrence Hy; Jung, Hwoon-Young; Sollano, Jose D; Gotoda, Takuji; Reddy, Nageshwar; Singh, Rajvinder; Sugano, Kentaro; Wu, Kai-Chun; Wu, Chun-Yin; Bjorkman, David J; Jensen, Dennis M; Kuipers, Ernst J; Lanas, Angel
2018-04-24
Non-variceal upper gastrointestinal bleeding remains an important emergency condition, leading to significant morbidity and mortality. As endoscopic therapy is the 'gold standard' of management, treatment of these patients can be considered in three stages: pre-endoscopic treatment, endoscopic haemostasis and post-endoscopic management. Since publication of the Asia-Pacific consensus on non-variceal upper gastrointestinal bleeding (NVUGIB) 7 years ago, there have been significant advancements in the clinical management of patients in all three stages. These include pre-endoscopy risk stratification scores, blood and platelet transfusion, use of proton pump inhibitors; during endoscopy new haemostasis techniques (haemostatic powder spray and over-the-scope clips); and post-endoscopy management by second-look endoscopy and medication strategies. Emerging techniques, including capsule endoscopy and Doppler endoscopic probe in assessing adequacy of endoscopic therapy, and the pre-emptive use of angiographic embolisation, are attracting new attention. An emerging problem is the increasing use of dual antiplatelet agents and direct oral anticoagulants in patients with cardiac and cerebrovascular diseases. Guidelines on the discontinuation and then resumption of these agents in patients presenting with NVUGIB are very much needed. The Asia-Pacific Working Group examined recent evidence and recommends practical management guidelines in this updated consensus statement. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Wireless technologies for robotic endoscope in gastrointestinal tract.
Gao, P; Yan, G; Wang, Z; Liu, H
2012-07-01
This paper introduces wireless technologies for use with robotic endoscopes in the gastrointestinal tract. The technologies include wireless power transmission (WPT), wireless remote control (WRC), and wireless image transmission (WIT). WPT, based on the electromagnetic coupling principle, powers active locomotion actuators and other peripherals in large air gaps. WRC, based on real-time bidirectional communication, has a multikernel frame in vivo to realize real-time multitasking. WIT provides a continuous dynamic image with a revolution of 320 × 240 pixel at 30 fps for in vitro diagnosis. To test these wireless technologies, three robotic endoscope prototypes were fabricated and equipped with the customized modules. The experimental results show that the wireless technologies have value for clinical applications.
Yu, Yong; Hu, Fan; Zhang, Xiaobiao; Ge, Junqi; Sun, Chongjing
2013-11-01
Transoral microscopic odontoidectomy has been accepted as a standard procedure to treat basilar invagination over the past several decades. In recent years the emergence of new technologies, including endoscopic odontoidectomy and posterior reduction, has presented a challenge to the traditional treatment algorithm. In this article, the authors describe 1 patient with basilar invagination who was successfully treated with endoscopic transnasal odontoidectomy combined with posterior reduction. The purpose of this report is to validate the effectiveness of this treatment algorithm in selected cases and describe several operative nuances and pearls based on the authors' experience. One patient with basilar invagination caused by a congenital osseous malformation underwent endoscopic transnasal odontoidectomy combined with posterior reduction in a single operative setting. The purely endoscopic transnasal odontoidectomy was first conducted with the patient supine. The favorable anatomical reduction was then achieved through a posterior approach after the patient was moved prone. The patient was extubated after recovery from anesthesia and allowed oral food intake the next day. No complications were noted, and the patient was discharged 4 days after the operation. Postoperative imaging demonstrated excellent decompression of the anterior cervicomedullary junction pathology. The patient was followed up for 12 months and remarkable neurological recovery was observed. The endoscopic transnasal odontoidectomy is a better minimally invasive approach for anterior decompression and can make the posterior reduction easier because the anterior resistant force is eliminated. The subsequent posterior reduction can make decompression of the ventral side of the cervicomedullary junction more effective because the C-2 vertebral body is pushed forward. A combination of these 2 approaches has the advantages of minimally invasive access and a faster patient recovery, and thus is a valid alternative in selected cases.
Emerging Endoscopic Imaging Technologies for Bladder Cancer Detection
Lopez, Aristeo; Liao, Joseph C.
2014-01-01
Modern urologic endoscopy is the result of continuous innovations since early 19th century. White light cystoscopy is the primary strategy for identification, resection, and local staging of bladder cancer. While highly effective, white light cystoscopy has several well-recognized shortcomings. Recent advances in optical imaging technologies and device miniaturization hold the potential to improve bladder cancer diagnosis and resection. Photodynamic diagnosis and narrow band imaging are the first to enter the clinical arena. Confocal laser endomicroscopy, optical coherence tomography, Raman spectroscopy, UV autofluorescence, and others have shown promising clinical and pre-clinical feasibility. We review their mechanisms of action, highlight their respective advantages, and propose future directions. PMID:24658832
History, Current Situation, and Future Development of Endoscopic Neurosurgery in China.
Li, Chuzhong; Zhu, Haibo; Zong, Xuyi; Wang, Xinsheng; Gui, Songbai; Zhao, Peng; Zhang, Yazhuo
2018-02-01
During the past few decades, Chinese endoscopic neurosurgery has rapidly developed in synchrony with the rest of the world. The aim of this article is to review the development of Chinese endoscopic neurosurgery, including its birth, growth, current situation, and prospects. The history of Chinese endoscopic neurosurgery development can be divided into 3 stages: cognition and initial stage (1964-1995), exploration and maturity stage (1995-2006), and rapid development and promotion stage (2006-present). In the first stage, we mainly began to become aware of endoscopic neurosurgery from the translation and review of literature. In the mid to late 1990s, Chinese neurosurgery pioneers began using neuroendoscopic techniques. In the following decade, many leading neurosurgeons made persistent efforts to push the development of Chinese endoscopic neurosurgery forward, focusing on advocating for and promoting and popularizing neuroendoscopic technology. In the rapid development and promotion stage, many representative national and regional neurosurgical centers became skilled and efficient in the application of neuroendoscopic technology and became new advocates of the technology. The number of cases, level of technology, and treatment effectiveness are gradually nearing international standards. However, future development requires promotion of balanced development to decrease regional disparities, further strengthen international exchanges, follow the latest developments, and constantly innovate for continuous improvement. Following the dramatic efforts of several pioneers, development of Chinese endoscopic neurosurgery has been considerable, and it has become an important component of neurosurgery worldwide. Copyright © 2017 Elsevier Inc. All rights reserved.
2007-01-01
In this Evaluation, we examine whether the Steris Reliance EPS--a flexible endoscope reprocessing system that was recently introduced to the U.S. market--offers meaningful advantages over "traditional" automated endoscope reprocessors (AERs). Most AERs on the market function similarly to one another. The Reliance EPS, however, includes some unique features that distinguish it from other AERs. For example, it incorporates a "boot" technology for loading the endoscopes into the unit without requiring a lot of endoscope-specific connectors, and it dispenses the germicide used to disinfect the endoscopes from a single-use container. This Evaluation looks at whether the unique features of this model make it a better choice than traditional AERs for reprocessing flexible endoscopes. Our study focuses on whether the Reliance EPS is any more likely to be used correctly-thereby reducing the likelihood that an endoscope will be reprocessed inadequately-and whether the unit possesses any design flaws that could lead to reprocessing failures. We detail the unit's advantages and disadvantages compared with other AERs, and we describe what current users have to say. Our conclusions will help facilities determine whether to select the Reliance EPS.
Endoscopes with latest technology and concept.
Gotoh
2003-09-01
Endoscopic imaging systems that perform as the "eye" of the operator during endoscopic surgical procedures have developed rapidly due to various technological developments. In addition, since the most recent turn of the century robotic surgery has increased its scope through the utilization of systems such as Intuitive Surgical's da Vinci System. To optimize the imaging required for precise robotic surgery, a unique endoscope has been developed, consisting of both a two dimensional (2D) image optical system for wider observation of the entire surgical field, and a three dimensional (3D) image optical system for observation of the more precise details at the operative site. Additionally, a "near infrared radiation" endoscopic system is under development to detect the sentinel lymph node more readily. Such progress in the area of endoscopic imaging is expected to enhance the surgical procedure from both the patient's and the surgeon's point of view.
Zheng, Mingwei; Liu, Xufeng; Li, Ning; Li, Wei-Zhi
2018-03-01
To evaluate the efficacy and safety of emergency endoscopic needle-knife precut papillotomy in acute severe cholangitis resulting from impacted common bile duct stones at duodenal papilla. Between January 2010 and January 2015, 118 cases of acute severe cholangitis with impacted common bile duct stones at the native papilla underwent emergency endoscopic retrograde cholangiopancreatography (ERCP) and early needle-knife precut papillotomy in a tertiary referral center. Precut techniques were performed according to the different locations of stones in the duodenal papilla. Clinical data about therapy and recovery of the 118 patients were recorded and analyzed. One hundred and eighteen patients underwent emergency ERCP within 24 h after hospitalization, with a total success rate of 100%. The mean operating time was 6.4 ± 4.1 min. Postoperative acute physiology and chronic health evaluation (APACHE) II scores, white blood cell count and liver function improved significantly. The complication rate was 4.2% (5/118); two with hemorrhage and three with acute pancreatitis. There was no procedure-related mortality. Emergency endoscopic needle-knife precut papillotomy is effective and safe for acute severe cholangitis resulting from impacted common bile duct stones at the duodenal papilla. Copyright © 2017 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.
Advances in the endoscopic management of pancreatic collections.
Ruiz-Clavijo, David; de la Higuera, Belen González; Vila, Juan J
2015-04-16
Treatment of pancreatic collections has experienced great progress in recent years with the emergence of alternative minimally invasive techniques comparing to the classic surgical treatment. Such techniques have been shown to improve outcomes of morbidity vs surgical treatment. The recent emergence of endoscopic drainage is noteworthy. The advent of endoscopic ultrasonography has been crucial for treatment of these specific lesions. They can be characterized, their relationships with neighboring structures can be evaluated and the drainage guided by this technique has been clearly improved compared with the conventional endoscopic drainage. Computed tomography is the technique of choice to characterize the recently published new classification of pancreatic collections. For this reason, the radiologist's role establishing and classifying in a rigorously manner the collections according to the new nomenclature is essential to making therapeutic decisions. Ideal scenario for comprehensive treatment of these collections would be those centers with endoscopic ultrasound and interventional radiology expertise together with hepatobiliopancreatic surgery. This review describes the different types of pancreatic collections: acute peripancreatic fluid collection, pancreatic pseudocysts, acute necrotic collection and walled-off necrosis; the indications and the contraindications for endoscopic drainage, the drainage technique and their outcomes. The integrated management of pancreatic collections according to their type and evolution time is discussed.
Emergency endoscopic management of dietary foreign bodies in the esophagus.
Lin, Hsuan-Hwai; Lee, Shih-Chun; Chu, Heng-Cheng; Chang, Wei-Kuo; Chao, You-Chen; Hsieh, Tsai-Yuan
2007-07-01
We report our experience of endoscopy in the emergency management of dietary foreign bodies. One hundred thirty-six patients were admitted to the emergency department (ED) between January 1997 and October 2006 for the endoscopic removal of esophageal dietary foreign bodies. They had a mean age of 47.7 years, and 91 (67%) were women. Most of the ingested materials (98.5%) were successfully extracted using either flexible or rigid endoscope. The objects most frequently ingested were fish bones (48%) and chicken bones (46%). Most of the objects (84%) were lodged in the upper esophagus. Two patients with irretrievable foreign bodies or complicated perforations were taken to surgery. Because most of these foreign bodies lodged in the upper esophagus, physicians should take care of this area to avoid secondary injury or complications, especially with sharp bones.
NASA Astrophysics Data System (ADS)
Efendiev, V. U.; Alsov, S. A.; Ruzmatov, T. M.; Mikheenko, I. L.; Chernyavsky, A. M.; Malakhov, E. S.
2015-11-01
A new technology - a thoracoscopic coronary bypass grafting with the use of Da Vinci robotic system in Russia is represented by the experience of NRICP. The technology was introduced in Russia in 2011. Overall, one hundred endoscopic coronary artery bypass procedures were performed. We have compared and analyzed results of coronary artery stenting vs minimally invasive coronary artery bypass grafting. According to the results, totally endoscopic coronary artery bypass grafting has several advantages over alternative treatment strategies.
Ultra-high definition (8K UHD) endoscope: our first clinical success.
Yamashita, Hiromasa; Aoki, Hisae; Tanioka, Kenkichi; Mori, Toshiyuki; Chiba, Toshio
2016-01-01
We have started clinical application of 8K ultra-high definition (UHD; 7680 × 4320 pixels) imaging technology, which is a 16-fold higher resolution than the current 2K high-definition (HD; 1920 × 1080 pixels) technology, to an endoscope for advanced laparoscopic surgery. Based on preliminary testing experience and with subsequent technical and system improvements, we then proceeded to perform two cases of cholecystectomy and were able to achieve clinical success with an 8K UHD endoscopic system, which consisted of an 8K camera, a 30-degrees angled rigid endoscope with a lens adapter, a pair of 300-W xenon light sources, an 85-inch 8K LCD and an 8K video recorder. These experimental and clinical studies revealed the engineering and clinical feasibility of the 8K UHD endoscope, enabling us to have a positive outlook on its prospective use in clinical practice. The 8K UHD endoscopy promises to open up new possibilities for intricate procedures including anastomoses of thin nerves and blood vessels as well as more confident surgical resections of a diversity of cancer tissues. 8K endoscopic imaging, compared to imaging by the current 2K imaging technology, is very likely to lead to major changes in the future of medical practice.
The Past, Present, and Future of Image-Enhanced Endoscopy
Jang, Jae-Young
2015-01-01
Despite the remarkable progress recently made to enhance the resolution of white-light endoscopy, detection, and diagnosis of premalignant lesions, such as adenomas and subtle early-stage cancers, remains a great challenge. As for example, although chromoendoscopy, such as endoscopy using indigo carmine, is useful for the early diagnosis of subtle lesions, the technique presents various disadvantages ranging from the time required for spray application of the dye and suctioning of excess dye to the increased difficulty in identifying lesions in the presence of severe inflammation and obstruction of visual field due to the pooling of solution in depressed-type lesions. To overcome these diagnostic problems associated with chromoendoscopy, research has focused on the development of endoscopes based on new optical technologies. Several types of image-enhanced endoscopy methods have recently been presented. In particular, image-enhanced endoscopy has emerged as a new paradigm for the diagnosis of gastrointestinal disorders. Image-enhanced endoscopes provide high-contrast images of lesions by means of optical or electronic technologies, including the contrast enhancement of the mucosal surface and of blood vessels. Chromoendoscopy, narrow-band imaging, i-SCAN, and flexible spectral imaging color enhancement are representative examples of image-enhanced endoscopy discussed in this paper. PMID:26668791
NASA Astrophysics Data System (ADS)
Huang, Shih-Wei; Chen, Shih-Hua; Chen, Weichung; Wu, I.-Chen; Wu, Ming Tsang; Kuo, Chie-Tong; Wang, Hsiang-Chen
2016-03-01
This study presents a method to identify early esophageal cancer within endoscope using hyperspectral imaging technology. The research samples are three kinds of endoscopic images including white light endoscopic, chromoendoscopic, and narrow-band endoscopic images with different stages of pathological changes (normal, dysplasia, dysplasia - esophageal cancer, and esophageal cancer). Research is divided into two parts: first, we analysis the reflectance spectra of endoscopic images with different stages to know the spectral responses by pathological changes. Second, we identified early cancerous lesion of esophagus by principal component analysis (PCA) of the reflectance spectra of endoscopic images. The results of this study show that the identification of early cancerous lesion is possible achieve from three kinds of images. In which the spectral characteristics of NBI endoscopy images of a gray area than those without the existence of the problem the first two, and the trend is very clear. Therefore, if simply to reflect differences in the degree of spectral identification, chromoendoscopic images are suitable samples. The best identification of early esophageal cancer is using the NBI endoscopic images. Based on the results, the use of hyperspectral imaging technology in the early endoscopic esophageal cancer lesion image recognition helps clinicians quickly diagnose. We hope for the future to have a relatively large amount of endoscopic image by establishing a hyperspectral imaging database system developed in this study, so the clinician can take this repository more efficiently preliminary diagnosis.
Current trends and pitfalls in endoscopic treatment of urolithiasis.
Inoue, Takaaki; Okada, Shinsuke; Hamamoto, Shuzo; Yoshida, Takashi; Matsuda, Tadashi
2018-02-01
Current development of endoscopic technology, lithotripters, and stone-retrieval devices has expanded the indications for retrograde and antegrade endoscopic therapy in the management of urolithiasis. This technology has also resulted in minimally invasive therapy. As surgeons' experience of endourological procedures with the newer instruments has become integrated, the surgical technique and indications for urolithiasis have also changed in the past few years. The present review provides an overview of endourological procedures for upper urinary tract stones and the key points related to surgical techniques. © 2017 The Japanese Urological Association.
Martin, Aaron; Kistler, Charles Andrew; Wrobel, Piotr; Yang, Juliana F.; Siddiqui, Ali A.
2016-01-01
The management of pancreaticobiliary disease in patients with surgically altered anatomy is a growing problem for gastroenterologists today. Over the years, endoscopic ultrasound (EUS) has emerged as an important diagnostic and therapeutic modality in the treatment of pancreaticobiliary disease. Patient anatomy has become increasingly complex due to advances in surgical resection of pancreaticobiliary disease and EUS has emerged as the therapy of choice when endoscopic retrograde cholangiopancreatography failed cannulation or when the papilla is inaccessible such as in gastric obstruction or duodenal obstruction. The current article gives a comprehensive review of the current literature for EUS-guided intervention of the pancreaticobiliary tract in patients with altered surgical anatomy. PMID:27386471
Terahertz endoscopic imaging for colorectal cancer detection: Current status and future perspectives
Doradla, Pallavi; Joseph, Cecil; Giles, Robert H
2017-01-01
Terahertz (THz) imaging is progressing as a robust platform for myriad applications in the field of security, health, and material science. The THz regime, which comprises wavelengths spanning from microns to millimeters, is non-ionizing and has very low photon energy: Making it inherently safe for biological imaging. Colorectal cancer is one of the most common causes of death in the world, while the conventional screening and standard of care yet relies exclusively on the physician’s experience. Researchers have been working on the development of a flexible THz endoscope, as a potential tool to aid in colorectal cancer screening. This involves building a single-channel THz endoscope, and profiling the THz response from colorectal tissue, and demonstrating endogenous contrast levels between normal and diseased tissue when imaging in reflection modality. The current level of contrast provided by the prototype THz endoscopic system represents a significant step towards clinical endoscopic application of THz technology for in-vivo colorectal cancer screening. The aim of this paper is to provide a short review of the recent advances in THz endoscopic technology and cancer imaging. In particular, the potential of single-channel THz endoscopic imaging for colonic cancer screening will be highlighted. PMID:28874955
Towards standardized assessment of endoscope optical performance: geometric distortion
NASA Astrophysics Data System (ADS)
Wang, Quanzeng; Desai, Viraj N.; Ngo, Ying Z.; Cheng, Wei-Chung; Pfefer, Joshua
2013-12-01
Technological advances in endoscopes, such as capsule, ultrathin and disposable devices, promise significant improvements in safety, clinical effectiveness and patient acceptance. Unfortunately, the industry lacks test methods for preclinical evaluation of key optical performance characteristics (OPCs) of endoscopic devices that are quantitative, objective and well-validated. As a result, it is difficult for researchers and developers to compare image quality and evaluate equivalence to, or improvement upon, prior technologies. While endoscope OPCs include resolution, field of view, and depth of field, among others, our focus in this paper is geometric image distortion. We reviewed specific test methods for distortion and then developed an objective, quantitative test method based on well-defined experimental and data processing steps to evaluate radial distortion in the full field of view of an endoscopic imaging system. Our measurements and analyses showed that a second-degree polynomial equation could well describe the radial distortion curve of a traditional endoscope. The distortion evaluation method was effective for correcting the image and can be used to explain other widely accepted evaluation methods such as picture height distortion. Development of consensus standards based on promising test methods for image quality assessment, such as the method studied here, will facilitate clinical implementation of innovative endoscopic devices.
ENDOSCOPIC DIAGNOSIS AND THERAPY IN GASTRO-ESOPAGEAL VARICEAL BLEEDING
Sanyal, Arun J.
2016-01-01
Gastroesophageal variceal hemorrhage is a medical emergency with high morbidity and mortality. Endoscopic therapy is the mainstay of management of bleeding varices. It requires attention to technique and the appropriate choice of therapy for a given patient at a given point in time. Subjects must be monitored continuously after initiation of therapy for control of bleeding and second line definitive therapies introduced quickly if endoscopic and pharmacologic treatment fails. PMID:26142034
Cecal intubation rates in different eras of endoscopic technological development.
Matyja, Maciej; Pasternak, Artur; Szura, Mirosław; Pędziwiatr, Michał; Major, Piotr; Rembiasz, Kazimierz
2018-03-01
Colonoscopy plays a critical role in colorectal cancer (CRC) screening and has been widely regarded as the gold standard. Cecal intubation rate (CIR) is one of the well-defined quality indicators used to assess colonoscopy. To assess the impact of new technologies on the quality of colonoscopy by assessing completion rates. This was a dual-center study at the 2 nd Department of Surgery at Jagiellonian University Medical College and at the Specialist Center "Medicina" in Krakow, Poland. The CIR and cecal intubation time (CIT) in three different eras of technological advancement were determined. The study enrolled 27 463 patients who underwent colonoscopy as part of a national CRC screening program. The patients were divided into three groups: group I - 3408 patients examined between 2000 and 2003 (optical endoscopes); group II - 10 405 patients examined between 2004 and 2008 (standard electronic endoscopes); and group III - 13 650 patients examined between 2009 and 2014 (modern endoscopes). There were statistically significant differences in the CIR between successive eras. The CIR in group I (2000-2003) was 69.75%, in group II (2004-2008) was 92.32%, and in group III (2009-2014) was 95.17%. The mean CIT was significantly reduced in group III. Our study shows that the technological innovation of novel endoscopy devices has a great influence on the effectiveness of the CRC screening program. The new era of endoscopic technological development has the potential to reduce examination-related patient discomfort, obviate the need for sedation and increase diagnostic yields.
Magnetic anchor guidance for endoscopic submucosal dissection and other endoscopic procedures
Mortagy, Mohamed; Mehta, Neal; Parsi, Mansour A; Abe, Seiichiro; Stevens, Tyler; Vargo, John J; Saito, Yutaka; Bhatt, Amit
2017-01-01
Endoscopic submucosal dissection (ESD) is a well-established, minimally invasive treatment for superficial neoplasms of the gastrointestinal tract. The universal adoption of ESD has been limited by its slow learning curve, long procedure times, and high risk of complications. One technical challenge is the lack of a second hand that can provide traction, as in conventional surgery. Reliable tissue retraction that exposes the submucosal plane of dissection would allow for safer and more efficient dissection. Magnetic anchor guided endoscopic submucosal dissection (MAG-ESD) has potential benefits compared to other current traction methods. MAG-ESD offers dynamic tissue retraction independent of the endoscope mimicking a surgeon’s “second hand”. Two types of magnets can be used: electromagnets and permanent magnets. In this article we review the MAG-ESD technology, published work and studies of magnets in ESD. We also review the use of magnetic anchor guidance systems in natural orifice transluminal endoscopic surgery and the idea of magnetic non-contact retraction using surface ferromagentization. We discuss the current limitations, the future potential of MAG-ESD and the developments needed for adoption of this technology. PMID:28522906
Laws, Edward R; Barkhoudarian, Garni
2014-12-01
As interest and enthusiasm for the use of the endoscope in transsphenoidal anterior skull base and pituitary surgery increases, neurosurgeons are increasingly adopting endoscopic technology and associated novel concepts. Often this involves a transition from the standard operating microscope as the main means of visualization to the operating endoscope (2D or 3D) during surgery. The authors' experience with this transition is described, including the rationale, advantages and disadvantages of the two surgical techniques. The successful use of endoscopic surgery for a large variety of pathological problems involving the anterior skull base and the pituitary region is presented. Perceived advantages for the patient and the surgeon are described, as is the occasional need for transition back to the microscopic approach. The endoscopic approach and its allied technology are here to stay. They are useful and occasionally preferable methods for treating a variety of suitable lesions involving the anterior skull base. The importance of incorporating the basic principles of skull base surgery is emphasized. Copyright © 2014 Elsevier Inc. All rights reserved.
Endoscope field of view measurement.
Wang, Quanzeng; Khanicheh, Azadeh; Leiner, Dennis; Shafer, David; Zobel, Jurgen
2017-03-01
The current International Organization for Standardization (ISO) standard (ISO 8600-3: 1997 including Amendment 1: 2003) for determining endoscope field of view (FOV) does not accurately characterize some novel endoscopic technologies such as endoscopes with a close focus distance and capsule endoscopes. We evaluated the endoscope FOV measurement method (the FOV WS method) in the current ISO 8600-3 standard and proposed a new method (the FOV EP method). We compared the two methods by measuring the FOV of 18 models of endoscopes (one device for each model) from seven key international manufacturers. We also estimated the device to device variation of two models of colonoscopes by measuring several hundreds of devices. Our results showed that the FOV EP method was more accurate than the FOV WS method, and could be used for all endoscopes. We also found that the labelled FOV values of many commercial endoscopes are significantly overstated. Our study can help endoscope users understand endoscope FOV and identify a proper method for FOV measurement. This paper can be used as a reference to revise the current endoscope FOV measurement standard.
Endoscope field of view measurement
Wang, Quanzeng; Khanicheh, Azadeh; Leiner, Dennis; Shafer, David; Zobel, Jurgen
2017-01-01
The current International Organization for Standardization (ISO) standard (ISO 8600-3: 1997 including Amendment 1: 2003) for determining endoscope field of view (FOV) does not accurately characterize some novel endoscopic technologies such as endoscopes with a close focus distance and capsule endoscopes. We evaluated the endoscope FOV measurement method (the FOVWS method) in the current ISO 8600-3 standard and proposed a new method (the FOVEP method). We compared the two methods by measuring the FOV of 18 models of endoscopes (one device for each model) from seven key international manufacturers. We also estimated the device to device variation of two models of colonoscopes by measuring several hundreds of devices. Our results showed that the FOVEP method was more accurate than the FOVWS method, and could be used for all endoscopes. We also found that the labelled FOV values of many commercial endoscopes are significantly overstated. Our study can help endoscope users understand endoscope FOV and identify a proper method for FOV measurement. This paper can be used as a reference to revise the current endoscope FOV measurement standard. PMID:28663840
Design and modeling of a prototype fiber scanning CARS endoscope
NASA Astrophysics Data System (ADS)
Veilleux, Isra"l.; Doucet, Michel; Coté, Patrice; Verreault, Sonia; Fortin, Michel; Paradis, Patrick; Leclair, Sébastien; Da Costa, Ralph S.; Wilson, Brian C.; Seibel, Eric; Mermut, Ozzy; Cormier, Jean-François
2010-02-01
An endoscope capable of Coherent Anti-Stokes Raman scattering (CARS) imaging would be of significant clinical value for improving early detection of endoluminal cancers. However, developing this technology is challenging for many reasons. First, nonlinear imaging techniques such as CARS are single point measurements thus requiring fast scanning in a small footprint if video rate is to be achieved. Moreover, the intrinsic nonlinearity of this modality imposes several technical constraints and limitations, mainly related to pulse and beam distortions that occur within the optical fiber and the focusing objective. Here, we describe the design and report modeling results of a new CARS endoscope. The miniature microscope objective design and its anticipated performance are presented, along with its compatibility with a new spiral scanningfiber imaging technology developed at the University of Washington. This technology has ideal attributes for clinical use, with its small footprint, adjustable field-of-view and high spatial-resolution. This compact hybrid fiber-based endoscopic CARS imaging design is anticipated to have a wide clinical applicability.
Management of a large mucosal defect after duodenal endoscopic resection
Fujihara, Shintaro; Mori, Hirohito; Kobara, Hideki; Nishiyama, Noriko; Matsunaga, Tae; Ayaki, Maki; Yachida, Tatsuo; Masaki, Tsutomu
2016-01-01
Duodenal endoscopic resection is the most difficult type of endoscopic treatment in the gastrointestinal tract (GI) and is technically challenging because of anatomical specificities. In addition to these technical difficulties, this procedure is associated with a significantly higher rate of complication than endoscopic treatment in other parts of the GI tract. Postoperative delayed perforation and bleeding are hazardous complications, and emergency surgical intervention is sometimes required. Therefore, it is urgently necessary to establish a management protocol for preventing serious complications. For instance, the prophylactic closure of large mucosal defects after endoscopic resection may reduce the risk of hazardous complications. However, the size of mucosal defects after endoscopic submucosal dissection (ESD) is relatively large compared with the size after endoscopic mucosal resection, making it impossible to achieve complete closure using only conventional clips. The over-the-scope clip and polyglycolic acid sheets with fibrin gel make it possible to close large mucosal defects after duodenal ESD. In addition to the combination of laparoscopic surgery and endoscopic resection, endoscopic full-thickness resection holds therapeutic potential for difficult duodenal lesions and may overcome the disadvantages of endoscopic resection in the near future. This review aims to summarize the complications and closure techniques of large mucosal defects and to highlight some directions for management after duodenal endoscopic treatment. PMID:27547003
Current Status of Peroral Endoscopic Myotomy
Cho, Young Kwan; Kim, Seong Hwan
2018-01-01
Peroral endoscopic myotomy (POEM) has been established as an optional treatment for achalasia. POEM is an endoluminal procedure that involves dissection of esophageal muscle fibers followed by submucosal tunneling. Inoue first attempted to use POEM for the treatment of achalasia in humans. Expanded indications of POEM include classic indications such as type I, type II, type III achalasia, failed prior treatments, including Botulinum toxin injection, endoscopic balloon dilation, laparoscopic Heller myotomy, and hypertensive motor disorders such as diffuse esophageal spasm, jackhammer esophagus. Contraindications include prior radiation therapy to the esophagus and prior extensive esophageal mucosal resection/ablation involving the POEM field. Most of the complications are minor and self-limited and can be managed conservatively. As POEM emerged as the main treatment for achalasia, various adaptations to tunnel endoscopic surgery have been attempted. Tunnel endoscopic surgery includes POEM, peroral endoscopic tumor resection, gastric peroral endoscopic pyloromyotomy. POEM has been widely accepted as a treatment for all types of achalasia, even for specific cases such as achalasia with failed prior treatments, and hypertensive motor disorders. PMID:29397656
Current Status of Peroral Endoscopic Myotomy.
Cho, Young Kwan; Kim, Seong Hwan
2018-01-01
Peroral endoscopic myotomy (POEM) has been established as an optional treatment for achalasia. POEM is an endoluminal procedure that involves dissection of esophageal muscle fibers followed by submucosal tunneling. Inoue first attempted to use POEM for the treatment of achalasia in humans. Expanded indications of POEM include classic indications such as type I, type II, type III achalasia, failed prior treatments, including Botulinum toxin injection, endoscopic balloon dilation, laparoscopic Heller myotomy, and hypertensive motor disorders such as diffuse esophageal spasm, jackhammer esophagus. Contraindications include prior radiation therapy to the esophagus and prior extensive esophageal mucosal resection/ablation involving the POEM field. Most of the complications are minor and self-limited and can be managed conservatively. As POEM emerged as the main treatment for achalasia, various adaptations to tunnel endoscopic surgery have been attempted. Tunnel endoscopic surgery includes POEM, peroral endoscopic tumor resection, gastric peroral endoscopic pyloromyotomy. POEM has been widely accepted as a treatment for all types of achalasia, even for specific cases such as achalasia with failed prior treatments, and hypertensive motor disorders.
Cecal intubation rates in different eras of endoscopic technological development
Pasternak, Artur; Szura, Mirosław; Pędziwiatr, Michał; Major, Piotr; Rembiasz, Kazimierz
2018-01-01
Introduction Colonoscopy plays a critical role in colorectal cancer (CRC) screening and has been widely regarded as the gold standard. Cecal intubation rate (CIR) is one of the well-defined quality indicators used to assess colonoscopy. Aim To assess the impact of new technologies on the quality of colonoscopy by assessing completion rates. Material and methods This was a dual-center study at the 2nd Department of Surgery at Jagiellonian University Medical College and at the Specialist Center “Medicina” in Krakow, Poland. The CIR and cecal intubation time (CIT) in three different eras of technological advancement were determined. The study enrolled 27 463 patients who underwent colonoscopy as part of a national CRC screening program. The patients were divided into three groups: group I – 3408 patients examined between 2000 and 2003 (optical endoscopes); group II – 10 405 patients examined between 2004 and 2008 (standard electronic endoscopes); and group III – 13 650 patients examined between 2009 and 2014 (modern endoscopes). Results There were statistically significant differences in the CIR between successive eras. The CIR in group I (2000–2003) was 69.75%, in group II (2004–2008) was 92.32%, and in group III (2009–2014) was 95.17%. The mean CIT was significantly reduced in group III. Conclusions Our study shows that the technological innovation of novel endoscopy devices has a great influence on the effectiveness of the CRC screening program. The new era of endoscopic technological development has the potential to reduce examination-related patient discomfort, obviate the need for sedation and increase diagnostic yields. PMID:29643961
Image-enhanced endoscopy with I-scan technology for the evaluation of duodenal villous patterns.
Cammarota, Giovanni; Ianiro, Gianluca; Sparano, Lucia; La Mura, Rossella; Ricci, Riccardo; Larocca, Luigi M; Landolfi, Raffaele; Gasbarrini, Antonio
2013-05-01
I-scan technology is the newly developed endoscopic tool that works in real time and utilizes a digital contrast method to enhance endoscopic image. We performed a feasibility study aimed to determine the diagnostic accuracy of i-scan technology for the evaluation of duodenal villous patterns, having histology as the reference standard. In this prospective, single center, open study, patients undergoing upper endoscopy for an histological evaluation of duodenal mucosa were enrolled. All patients underwent upper endoscopy using high resolution view in association with i-scan technology. During endoscopy, duodenal villous patterns were evaluated and classified as normal, partial villous atrophy, or marked villous atrophy. Results were then compared with histology. One hundred fifteen subjects were recruited in this study. The endoscopist was able to find marked villous atrophy of the duodenum in 12 subjects, partial villous atrophy in 25, and normal villi in the remaining 78 individuals. The i-scan system was demonstrated to have great accuracy (100 %) in the detection of marked villous atrophy patterns. I-scan technology showed quite lower accuracy in determining partial villous atrophy or normal villous patterns (respectively, 90 % for both items). Image-enhancing endoscopic technology allows a clear visualization of villous patterns in the duodenum. By switching from the standard to the i-scan view, it is possible to optimize the accuracy of endoscopy in recognizing villous alteration in subjects undergoing endoscopic evaluation.
Gastrointestinal endoscopy in pregnancy
Savas, Nurten
2014-01-01
Gastrointestinal endoscopy has a major diagnostic and therapeutic role in most gastrointestinal disorders; however, limited information is available about clinical efficacy and safety in pregnant patients. The major risks of endoscopy during pregnancy include potential harm to the fetus because of hypoxia, premature labor, trauma and teratogenesis. In some cases, endoscopic procedures may be postponed until after delivery. When emergency or urgent indications are present, endoscopic procedures may be considered with some precautions. United States Food and Drug Administration category B drugs may be used in low doses. Endoscopic procedures during pregnancy may include upper gastrointestinal endoscopy, percutaneous endoscopic gastrostomy, sigmoidoscopy, colonoscopy, enteroscopy of the small bowel or video capsule endoscopy, endoscopic retrograde cholangiopancreatography and endoscopic ultrasonography. All gastrointestinal endoscopic procedures in pregnant patients should be performed in hospitals by expert endoscopists and an obstetrician should be informed about all endoscopic procedures. The endoscopy and flexible sigmoidoscopy may be safe for the fetus and pregnant patient, and may be performed during pregnancy when strong indications are present. Colonoscopy for pregnant patients may be considered for strong indications during the second trimester. Although therapeutic endoscopic retrograde cholangiopancreatography may be considered during pregnancy, this procedure should be performed only for strong indications and attempts should be made to minimize radiation exposure. PMID:25386072
NASA Technical Reports Server (NTRS)
2000-01-01
The Automated Endoscopic System for Optimal Positioning, or AESOP, was developed by Computer Motion, Inc. under a SBIR contract from the Jet Propulsion Lab. AESOP is a robotic endoscopic positioning system used to control the motion of a camera during endoscopic surgery. The camera, which is mounted at the end of a robotic arm, previously had to be held in place by the surgical staff. With AESOP the robotic arm can make more precise and consistent movements. AESOP is also voice controlled by the surgeon. It is hoped that this technology can be used in space repair missions which require precision beyond human dexterity. A new generation of the same technology entitled the ZEUS Robotic Surgical System can make endoscopic procedures even more successful. ZEUS allows the surgeon control various instruments in its robotic arms, allowing for the precision the procedure requires.
NASA Astrophysics Data System (ADS)
Wang, Quanzeng; Cheng, Wei-Chung; Suresh, Nitin; Hua, Hong
2016-05-01
With improved diagnostic capabilities and complex optical designs, endoscopic technologies are advancing. As one of the several important optical performance characteristics, geometric distortion can negatively affect size estimation and feature identification related diagnosis. Therefore, a quantitative and simple distortion evaluation method is imperative for both the endoscopic industry and the medical device regulatory agent. However, no such method is available yet. While the image correction techniques are rather mature, they heavily depend on computational power to process multidimensional image data based on complex mathematical model, i.e., difficult to understand. Some commonly used distortion evaluation methods, such as the picture height distortion (DPH) or radial distortion (DRAD), are either too simple to accurately describe the distortion or subject to the error of deriving a reference image. We developed the basic local magnification (ML) method to evaluate endoscope distortion. Based on the method, we also developed ways to calculate DPH and DRAD. The method overcomes the aforementioned limitations, has clear physical meaning in the whole field of view, and can facilitate lesion size estimation during diagnosis. Most importantly, the method can facilitate endoscopic technology to market and potentially be adopted in an international endoscope standard.
Chan, Harley H L; Siewerdsen, Jeffrey H; Vescan, Allan; Daly, Michael J; Prisman, Eitan; Irish, Jonathan C
2015-01-01
The aim of this study was to demonstrate the role of advanced fabrication technology across a broad spectrum of head and neck surgical procedures, including applications in endoscopic sinus surgery, skull base surgery, and maxillofacial reconstruction. The initial case studies demonstrated three applications of rapid prototyping technology are in head and neck surgery: i) a mono-material paranasal sinus phantom for endoscopy training ii) a multi-material skull base simulator and iii) 3D patient-specific mandible templates. Digital processing of these phantoms is based on real patient or cadaveric 3D images such as CT or MRI data. Three endoscopic sinus surgeons examined the realism of the endoscopist training phantom. One experienced endoscopic skull base surgeon conducted advanced sinus procedures on the high-fidelity multi-material skull base simulator. Ten patients participated in a prospective clinical study examining patient-specific modeling for mandibular reconstructive surgery. Qualitative feedback to assess the realism of the endoscopy training phantom and high-fidelity multi-material phantom was acquired. Conformance comparisons using assessments from the blinded reconstructive surgeons measured the geometric performance between intra-operative and pre-operative reconstruction mandible plates. Both the endoscopy training phantom and the high-fidelity multi-material phantom received positive feedback on the realistic structure of the phantom models. Results suggested further improvement on the soft tissue structure of the phantom models is necessary. In the patient-specific mandible template study, the pre-operative plates were judged by two blinded surgeons as providing optimal conformance in 7 out of 10 cases. No statistical differences were found in plate fabrication time and conformance, with pre-operative plating providing the advantage of reducing time spent in the operation room. The applicability of common model design and fabrication techniques across a variety of otolaryngological sub-specialties suggests an emerging role for rapid prototyping technology in surgical education, procedure simulation, and clinical practice.
Chan, Harley H. L.; Siewerdsen, Jeffrey H.; Vescan, Allan; Daly, Michael J.; Prisman, Eitan; Irish, Jonathan C.
2015-01-01
The aim of this study was to demonstrate the role of advanced fabrication technology across a broad spectrum of head and neck surgical procedures, including applications in endoscopic sinus surgery, skull base surgery, and maxillofacial reconstruction. The initial case studies demonstrated three applications of rapid prototyping technology are in head and neck surgery: i) a mono-material paranasal sinus phantom for endoscopy training ii) a multi-material skull base simulator and iii) 3D patient-specific mandible templates. Digital processing of these phantoms is based on real patient or cadaveric 3D images such as CT or MRI data. Three endoscopic sinus surgeons examined the realism of the endoscopist training phantom. One experienced endoscopic skull base surgeon conducted advanced sinus procedures on the high-fidelity multi-material skull base simulator. Ten patients participated in a prospective clinical study examining patient-specific modeling for mandibular reconstructive surgery. Qualitative feedback to assess the realism of the endoscopy training phantom and high-fidelity multi-material phantom was acquired. Conformance comparisons using assessments from the blinded reconstructive surgeons measured the geometric performance between intra-operative and pre-operative reconstruction mandible plates. Both the endoscopy training phantom and the high-fidelity multi-material phantom received positive feedback on the realistic structure of the phantom models. Results suggested further improvement on the soft tissue structure of the phantom models is necessary. In the patient-specific mandible template study, the pre-operative plates were judged by two blinded surgeons as providing optimal conformance in 7 out of 10 cases. No statistical differences were found in plate fabrication time and conformance, with pre-operative plating providing the advantage of reducing time spent in the operation room. The applicability of common model design and fabrication techniques across a variety of otolaryngological sub-specialties suggests an emerging role for rapid prototyping technology in surgical education, procedure simulation, and clinical practice. PMID:26331717
Endoscopic Devices for Obesity.
Sampath, Kartik; Dinani, Amreen M; Rothstein, Richard I
2016-06-01
The obesity epidemic, recognized by the World Health Organization in 1997, refers to the rising incidence of obesity worldwide. Lifestyle modification and pharmacotherapy are often ineffective long-term solutions; bariatric surgery remains the gold standard for long-term obesity weight loss. Despite the reported benefits, it has been estimated that only 1% of obese patients will undergo surgery. Endoscopic treatment for obesity represents a potential cost-effective, accessible, minimally invasive procedure that can function as a bridge or alternative intervention to bariatric surgery. We review the current endoscopic bariatric devices including space occupying devices, endoscopic gastroplasty, aspiration technology, post-bariatric surgery endoscopic revision, and obesity-related NOTES procedures. Given the diverse devices already FDA approved and in development, we discuss the future directions of endoscopic therapies for obesity.
Mohammed, Noor; Subramanian, Venkataraman
2016-01-01
Ulcerative colitis (UC) is a chronic inflammatory bowel condition characterised by a relapsing and remitting course. Symptom control has been the traditional mainstay of medical treatment. It is well known that histological inflammatory activity persists despite adequate symptom control and absence of endoscopic inflammation. Current evidence suggests that presence of histological inflammation poses a greater risk of disease relapse and subsequent colorectal cancer risk. New endoscopic technologies hold promise for developing endoscopic markers of mucosal inflammation. Achieving endoscopic and histological remission appears be the future aim of medical treatments for UC. This review article aims to evaluate the use of endoscopy as a tool in assessment of mucosal inflammation UC and its correlation with disease outcomes. PMID:27895420
Towards automated visual flexible endoscope navigation.
van der Stap, Nanda; van der Heijden, Ferdinand; Broeders, Ivo A M J
2013-10-01
The design of flexible endoscopes has not changed significantly in the past 50 years. A trend is observed towards a wider application of flexible endoscopes with an increasing role in complex intraluminal therapeutic procedures. The nonintuitive and nonergonomical steering mechanism now forms a barrier in the extension of flexible endoscope applications. Automating the navigation of endoscopes could be a solution for this problem. This paper summarizes the current state of the art in image-based navigation algorithms. The objectives are to find the most promising navigation system(s) to date and to indicate fields for further research. A systematic literature search was performed using three general search terms in two medical-technological literature databases. Papers were included according to the inclusion criteria. A total of 135 papers were analyzed. Ultimately, 26 were included. Navigation often is based on visual information, which means steering the endoscope using the images that the endoscope produces. Two main techniques are described: lumen centralization and visual odometry. Although the research results are promising, no successful, commercially available automated flexible endoscopy system exists to date. Automated systems that employ conventional flexible endoscopes show the most promising prospects in terms of cost and applicability. To produce such a system, the research focus should lie on finding low-cost mechatronics and technologically robust steering algorithms. Additional functionality and increased efficiency can be obtained through software development. The first priority is to find real-time, robust steering algorithms. These algorithms need to handle bubbles, motion blur, and other image artifacts without disrupting the steering process.
Geraci, Girolamo; Sciume', Carmelo; Di Carlo, Giovanni; Picciurro, Antonino; Modica, Giuseppe
2016-11-04
Ingestion of foreign bodies and food impaction represent the second most common endoscopic emergency after bleeding. The aim of this paper is to report the management and the outcomes in 67 patients admitted for suspected ingestion of foreign body between December 2012 and December 2014. This retrospective study was conducted at Palermo University Hospitals, Italy, over a 2-year period. We reviewed patients' database (age, sex, type of foreign body and its anatomical location, treatments, and outcomes as complications, success rates, and mortalities). Foreign bodies were found in all of our 67 patients. Almost all were found in the stomach and lower esophagus (77 %). The types of foreign body were very different, but they were chiefly meat boluses, fishbones or cartilages, button battery and dental prostheses. In all patients it was possible to endoscopically remove the foreign body. Complications related to the endoscopic procedure were unfrequent (about 7 %) and have been treated conservatively. 5.9 % of patients had previous esophageal or laryngeal surgery, and 8.9 % had an underlying esophageal disease, such as a narrowing, dismotility or achalasia. Our experience with foreign bodies and food impaction emphasizes the importance of endoscopic approach and removal, simple and secure when performed by experienced hands and under conscious sedation in most cases. High success rates, lower incidence of minor complications, reduction of the need of surgery and reduced hospitalization time are the strengths of the endoscopic approach.
White Paper AGA: Advanced Imaging in Barrett's Esophagus.
Sharma, Prateek; Brill, Joel; Canto, Marcia; DeMarco, Daniel; Fennerty, Brian; Gupta, Neil; Laine, Loren; Lieberman, David; Lightdale, Charles; Montgomery, Elizabeth; Odze, Robert; Tokar, Jeffrey; Kochman, Michael
2015-12-01
Enhanced imaging technologies such as narrow band imaging, flexible spectral imaging color enhancement, i-Scan, confocal laser endomicroscopy, and optical coherence tomography are readily available for use by endoscopists in routine clinical practice. In November 2014, the American Gastroenterological Association's Center for GI Innovation and Technology conducted a 2-day workshop to discuss endoscopic image enhancement technologies, focusing on their role in 2 specific clinical conditions (colon polyps and Barrett's esophagus) and on issues relating to training and implementation of these technologies (white papers). Although the majority of the studies that use enhanced imaging technologies have been positive, these techniques ideally need to be validated in larger cohorts and in community centers. As it stands today, detailed endoscopic examination with high-definition white-light endoscopy and random 4-quadrant biopsy remains the standard of care. However, the workshop panelists agreed that in the hands of endoscopists who have met the preservation and incorporation of valuable endoscopic innovation thresholds (diagnostic accuracy) with enhanced imaging techniques (specific technologies), use of the technique in Barrett's esophagus patients is appropriate. Copyright © 2015 AGA Institute. Published by Elsevier Inc. All rights reserved.
Application of robotics in gastrointestinal endoscopy: A review
Yeung, Baldwin Po Man; Chiu, Philip Wai Yan
2016-01-01
Multiple robotic flexible endoscope platforms have been developed based on cross specialty collaboration between engineers and medical doctors. However, significant number of these platforms have been developed for the natural orifice transluminal endoscopic surgery paradigm. Increasing amount of evidence suggest the focus of development should be placed on advanced endolumenal procedures such as endoscopic submucosal dissection instead. A thorough literature analysis was performed to assess the current status of robotic flexible endoscopic platforms designed for advanced endolumenal procedures. Current efforts are mainly focused on robotic locomotion and robotic instrument control. In the future, advances in actuation and servoing technology, optical analysis, augmented reality and wireless power transmission technology will no doubt further advance the field of robotic endoscopy. Globally, health systems have become increasingly budget conscious; widespread acceptance of robotic endoscopy will depend on careful design to ensure its delivery of a cost effective service. PMID:26855540
Forgione, A
2009-06-01
The possibility to operate inside the peritoneal cavity through small holes performed in hollow organs that is presented by Natural Orifice Transluminal Endoscopic Surgery (NOTES) represents a major paradigm shift in general surgery. While this new approach seems very appealing from patients' perspectives because it eliminates completely abdominal wall aggression and promises to reduce postoperative pain, it is very challenging for surgeons because of the major constraints imposed by both the mode of access and the limited technology currently available. For this reason NOTES applications at the present time are performed by only a few surgeons and mainly to perform non-complex procedures. While new devices are under development, many of them are trying mainly to simply improve current endoscopic platforms and seem not to offer breakthrough solutions. The numerous challenges introduced by natural orifice approaches require a radical shift in the conception of new technologies in order to make this emerging operative access safe and reproducible. The convergence of several enabling technologies in the field of miniaturization, communication and micro-mechatronics brings the possibility to realize on a large scale the revolutionary concept of miniature in vivo co-operative robots. These robots provide vision and task assistance without the constraints of the entry incision and have been shown in experimental settings to possess many qualities that could be ideal to partner with Natural Orifice Surgery. This article explores the current status of microrobotics as well as presents potential future scenarios of their applications in NOTES.
Lee, Cameron M.; Engelbrecht, Christoph J.; Soper, Timothy D.; Helmchen, Fritjof; Seibel, Eric J.
2011-01-01
In modern endoscopy, wide field of view and full color are considered necessary for navigating inside the body, inspecting tissue for disease and guiding interventions such as biopsy or surgery. Current flexible endoscope technologies suffer from reduced resolution when device diameter shrinks. Endoscopic procedures today using coherent fiber bundle technology, on the scale of 1 mm, are performed with such poor image quality that the clinician’s vision meets the criteria for legal blindness. Here, we review a new and versatile scanning fiber imaging technology and describe its implementation for ultrathin and flexible endoscopy. This scanning fiber endoscope (SFE) or catheterscope enables high quality, laser-based, video imaging for ultrathin clinical applications while also providing new options for in vivo biological research of subsurface tissue and high resolution fluorescence imaging. PMID:20336702
Hashizume, M; Shimada, M; Tomikawa, M; Ikeda, Y; Takahashi, I; Abe, R; Koga, F; Gotoh, N; Konishi, K; Maehara, S; Sugimachi, K
2002-08-01
We performed a variety of complete total endoscopic general surgical procedures, including colon resection, distal gastrectomy, and splenectomy, successfully with the assistance of the da Vinci computer-enhanced surgical system. The robotic system allowed us to manipulate the endoscopic instruments as effectively as during open surgery. It enhanced visualization of both the operative field and precision of the necessary techniques, as well as being less stressful for the endoscopic operating team. This technological innovation can therefore help surgeons overcome many of the difficulties associated with the endoscopic approach and thus has the potential to enable more precise, safer, and more minimally invasive surgery in the future.
Anesthetic management of the SRS™ Endoscopic Stapling System for gastro-esophageal reflux disease.
Topuz, Ufuk; Umutoglu, Tarik; Bakan, Mefkur; Ozturk, Erdogan
2013-01-14
The SRS(TM) Endoscopic Stapling System (Medigus, Tel Aviv, Israel) is a new tool capable of creating a totally endoscopic fundoplication, combined with an endoscope, endoscopic ultrasound and a surgical stapler. SRS(TM) endoscopic stapling for gastro-esophageal reflux disease is a minimally invasive, outpatient procedure, which requires general anesthesia with positive-pressure ventilation. Keeping the patient on positive end-expiratory pressure (PEEP) may minimize the pressure gradient between the esophagus and the mediastinum, as well as help to prevent air from leaking around the screws and causing pneumomediastinum. In addition, in patients with hiatal hernia, higher PEEP levels may be required to increase intra-thoracic pressure and to force the stomach to slide into the abdomen for ease of endoscopy. We advise smoother emergence from anesthesia, taking precautions for retching, postoperative nausea and vomiting (PONV), while coughing and gagging during extubation and PONV may affect the success of the procedure. Total intravenous anesthesia with propofol and remifentanil seems to be a good choice for these reasons.
Overtube-Assisted Foreign Body Removal: A Review of Endoscopic Management and Case Illustration.
Ofosu, Andrew; Ramai, Daryl; Reddy, Madhavi
2017-09-29
The ingestion of foreign bodies is a common medical emergency seen in both adults and children. In children, the most commonly ingested foreign bodies include coins, toys, magnets, and batteries. In adults, food bolus impaction represents the most common cause of foreign body ingestion. The majority of foreign bodies pass spontaneously. Sharp or pointed objects increase the risk of perforation. Emergent endoscopic intervention is indicated in cases of esophageal obstruction, ingestion of disk batteries, and sharp pointed objects in the esophagus. Flexible endoscopy is the therapeutic method of choice for removing foreign bodies. It is preferred due to its high success rate and low risk for complications. Additionally, the use of an overtube provides gastric and esophageal protection from mucosal laceration. We present a 27-year-old male who ingested six razor blades and a curtain hook and review endoscopic management.
Prasad, Sunil M.; Ducko, Christopher T.; Stephenson, Edward R.; Chambers, Charles E.; Damiano, Ralph J.
2001-01-01
Objective To follow up in prospective fashion patients with coronary artery anastomoses completed endoscopically with robotic assistance. The robotic system was evaluated for safety and its effectiveness in completing microsurgical coronary anastomoses. Summary Background Data Recently there has been an interest in using robotics and computers to enhance the surgeon’s ability to perform endoscopic cardiac surgery. This interest has stemmed from the rapid advancement of technology and the desire to make cardiac surgery less invasive. Using traditional endoscopic instruments, it has not been possible to perform coronary surgery. Methods Nineteen patients underwent robotically assisted endoscopic coronary artery bypass grafting of the left internal thoracic artery (LITA) to the left anterior descending artery (LAD). Two robotic instruments and one endoscopic camera were placed through three 5-mm ports. A robotic system was used to construct the LITA–LAD anastomosis. All other required grafts were completed by conventional techniques. Results Seventeen LITA–LAD grafts (89%) had adequate intraoperative flow. The mean LITA–LAD graft flow was 38.5 ± 5 mL/min. At 8 weeks, LITA–LAD grafts were assessed by angiography and showed 100% patency with thrombolysis in myocardial infarction (TIMI) I flow. At a mean follow-up of 17 ± 4.2 months, all patients were NYHA class I and there were no adverse cardiac events. Conclusions The results from the first prospective clinical trial of robotically assisted endoscopic coronary bypass surgery in the United States showed favorable short-term outcomes with no adverse events. Robotic assistance is an enabling technology allowing the performance of endoscopic coronary anastomoses. PMID:11371730
Complications of retrograde balloon cautery endopyelotomy.
Schwartz, B F; Stoller, M L
1999-11-01
Adult ureteropelvic junction obstruction is increasingly managed with endoscopic techniques. Retrograde balloon cautery endopyelotomy is quick, requires minimal hospital stay and allows most patients a rapid return to work. The complication rate of retrograde balloon cautery endopyelotomy ranges from 13 to 34%, with vascular injury in 0 to 16% of patients. We report 5 uncommon complications, including 4 vascular injuries, that clinicians should be familiar with when using this technique. We reviewed 52 retrograde endoscopic endopyelotomy procedures performed during a 5-year period. There were 5 uncommon complications. Accessory lower pole renal artery injuries occurred in 3 patients, 1 of whom presented 12 days after endopyelotomy. Embolization was successfully performed in all 3 cases and none had subsequent hypertension. In 1 case a right ovarian vein laceration was not evident on preoperative or postoperative angiography. Emergency post-embolization abdominal exploration revealed a 2 mm. injury to the right ovarian vein before entering the right renal vein close to the ureteropelvic junction incision. Nephrectomy and ovarian vein ligature were curative. In 1 case the electrocautery wire broke intracorporeally after firing, resulting in a bobby pin-like configuration. Successful removal was accomplished by twisting the catheter and wrapping the wire around the tip, enabling atraumatic removal. Retrograde balloon cautery endopyelotomy is an emerging technology with potential adverse outcomes. The complications we noted are complex and potentially life threatening. Awareness of these complications may help avoid poor outcomes and expedite appropriate treatment.
Endoscopic Management of Peri-Pancreatic Fluid Collections.
Yip, Hon Chi; Teoh, Anthony Yuen Bun
2017-09-15
In the past decade, there has been a progressive paradigm shift in the management of peri-pancreatic fluid collections after acute pancreatitis. Refinements in the definitions of fluid collections from the updated Atlanta classification have enabled better communication amongst physicians in an effort to formulate optimal treatments. Endoscopic ultrasound (EUS)-guided drainage of pancreatic pseudocysts has emerged as the procedure of choice over surgical cystogastrostomy. The approach provides similar success rates with low complications and better quality of life compared with surgery. However, an endoscopic "step up" approach in the management of pancreatic walled-off necrosis has also been advocated. Both endoscopic and percutaneous drainage routes may be used depending on the anatomical location of the collections. New-generation large diameter EUS-specific stent systems have also recently been described. The device allows precise and effective drainage of the collections and permits endoscopic necrosectomy through the stents.
Li, Meng; Wang, Thomas D
2011-01-01
Summary Endoscopy has undergone explosive technological growth in over recent years, and with the emergence of targeted imaging, its truly transformative power and impact in medicine lies just over the horizon. Today, our ability to see inside the digestive tract with medical endoscopy is headed toward exciting crossroads. The existing paradigm of making diagnostic decisions based on observing structural changes and identifying anatomical landmarks may soon be replaced by visualizing functional properties and imaging molecular expression. In this novel approach, the presence of intracellular and cell surface targets unique to disease are identified and used to predict the likelihood of mucosal transformation and response to therapy. This strategy can result in the development of new methods for early cancer detection, personalized therapy, and chemoprevention. This targeted approach will require further development of molecular probes and endoscopic instruments, and will need support from the FDA for streamlined regulatory oversight. Overall, this molecular imaging modality promises to significantly broaden the capabilities of the gastroenterologist by providing a new approach to visualize the mucosa of the digestive tract in a manner that has never been seen before. PMID:19423025
Wentink, M; Jakimowicz, J J; Vos, L M; Meijer, D W; Wieringa, P A
2002-08-01
Compared to open surgery, minimally invasive surgery (MIS) relies heavily on advanced technology, such as endoscopic viewing systems and innovative instruments. The aim of the study was to objectively compare three technologically advanced laparoscopic viewing systems with the standard viewing system currently used in most Dutch hospitals. We evaluated the following advanced laparoscopic viewing systems: a Thin Film Transistor (TFT) display, a stereo endoscope, and an image projection display. The standard viewing system was comprised of a monocular endoscope and a high-resolution monitor. Task completion time served as the measure of performance. Eight surgeons with laparoscopic experience participated in the experiment. The average task time was significantly greater (p <0.05) with the stereo viewing system than with the standard viewing system. The average task times with the TFT display and the image projection display did not differ significantly from the standard viewing system. Although the stereo viewing system promises improved depth perception and the TFT and image projection displays are supposed to improve hand-eye coordination, none of these systems provided better task performance than the standard viewing system in this pelvi-trainer experiment.
MEMS-based liquid lens for capsule endoscope
NASA Astrophysics Data System (ADS)
Seo, S. W.; Han, S.; Seo, J. H.; Kim, Y. M.; Kang, M. S.; Min, N. G.; Choi, W. B.; Sung, M. Y.
2008-03-01
The capsule endoscope, a new application area of digital imaging, is growing rapidly but needs the versatile imaging capabilities such as auto-focusing and zoom-in to be an active diagnostic tool. The liquid lens based on MEMS technology can be a strong candidate because it is able to be small enough. In this paper, a cylinder-type liquid lens was designed based on Young-Lippmann model and then fabricated with MEMS technology combining the silicon thin-film process and the wafer bonding process. The focal length of the lens module including the fabricated liquid lens was changed reproducibly as a function of the applied voltage. With the change of 30V in the applied bias, the focal length of the constructed lens module could be tuned in the range of about 42cm. The fabricated liquid lens was also proven to be small enough to be adopted in the capsule endoscope, which means the liquid lens can be utilized for the imaging capability improvement of the capsule endoscope.
Endoscopic ultrasound-guided biliary drainage
Chavalitdhamrong, Disaya; Draganov, Peter V
2012-01-01
Endoscopic ultrasound (EUS)-guided biliary drainage has emerged as a minimally invasive alternative to percutaneous and surgical interventions for patients with biliary obstruction who had failed endoscopic retrograde cholangiopancreatography (ERCP). EUS-guided biliary drainage has become feasible due to the development of large channel curvilinear therapeutic echo-endoscopes and the use of real-time ultrasound and fluoroscopy imaging in addition to standard ERCP devices and techniques. EUS-guided biliary drainage is an attractive option because of its minimally invasive, single step procedure which provides internal biliary decompression. Multiple investigators have reported high success and low complication rates. Unfortunately, high quality prospective data are still lacking. We provide detailed review of the use of EUS for biliary drainage from the perspective of practicing endoscopists with specific focus on the technical aspects of the procedure. PMID:22363114
Bao, Guanqun; Mi, Liang; Geng, Yishuang; Zhou, Mingda; Pahlavan, Kaveh
2014-01-01
Wireless Capsule Endoscopy (WCE) is progressively emerging as one of the most popular non-invasive imaging tools for gastrointestinal (GI) tract inspection. As a critical component of capsule endoscopic examination, physicians need to know the precise position of the endoscopic capsule in order to identify the position of intestinal disease. For the WCE, the position of the capsule is defined as the linear distance it is away from certain fixed anatomical landmarks. In order to measure the distance the capsule has traveled, a precise knowledge of how fast the capsule moves is urgently needed. In this paper, we present a novel computer vision based speed estimation technique that is able to extract the speed of the endoscopic capsule by analyzing the displacements between consecutive frames. The proposed approach is validated using a virtual testbed as well as the real endoscopic images. Results show that the proposed method is able to precisely estimate the speed of the endoscopic capsule with 93% accuracy on average, which enhances the localization accuracy of the WCE to less than 2.49 cm.
Design and control of 2-axis tilting actuator for endoscope using ionic polymer metal composites
NASA Astrophysics Data System (ADS)
Kim, Sung-Joo; Kim, Chul-Jin; Park, No-Cheol; Yang, Hyun-Seok; Park, Young-Pil
2009-03-01
In field of endoscopy, in order to overcome limitation in conventional endoscopy, capsule endoscope has been developed and has been recently applied in medical field in hospital. However, since capsule endoscope moves passively through GI tract by peristalsis, it is not able to control direction of head including camera. It is possible to miss symptoms of disease. Therefore, in this thesis, 2-Axis Tilting Actuator for Endoscope, based on Ionic Polymer Metal Composites (IPMC), is presented. In order to apply to capsule endoscope, the actuator material should satisfy a size, low energy consumption and low working voltage. Since IPMC is emerging material that exhibits a large bending deflection at low voltage, consume low energy and it can be fabricated in any size or any shape, IPMC are selected as an actuator. The system tilts camera module of endoscope to reduce invisible area of the intestines and a goal of tilting angle is selected to be an angle of 5 degrees for each axis. In order to control tiling angle, LQR controller and the full order observer is designed.
Matsuda, Dean K.; Matsuda, Nicole A.
2015-01-01
Beyond the recent expansion of extra-articular hip arthroscopy into the peri-trochanteric and subgluteal space, this instructional course lecture introduces three innovative procedures: endoscopy-assisted periacetabular osteotomy, closed derotational proximal femoral osteotomy and endoscopic pubic symphysectomy. Supportive rationale, evolving indications, key surgical techniques and emerging outcomes are presented for these innovative less invasive procedures. PMID:27011827
Medical and endoscopic treatment in peptic ulcer bleeding: a national German survey.
Maiss, J; Schwab, D; Ludwig, A; Naegel, A; Ende, A; Hahn, G; Zopf, Y
2010-02-01
Peptic ulcers are the leading cause of upper gastrointestinal (GI) bleeding. The aim of this study was the evaluation of the recent clinical practice in drug therapy and endoscopic treatment of ulcer bleedings in Germany and to compare the results with the medical standard. A structured questionnaire (cross-sectional study) was sent to 1371 German hospitals that provide an emergency service for upper GI bleeding. The project was designed similar to a nationwide inquiry in France in 2001. Forty-four questions concerning the following topics were asked: hospital organisation, organisation of emergency endoscopy service, endoscopic and drug therapy of ulcer bleeding, endoscopic treatment of variceal bleeding. Return of the questionnaires was closed in August 2004. Response rate was 675 / 1371 (49 %). Mean hospitals size was < 200 beds, 49 % (n = 325) had basic care level. 92 % provided a 24-hour endoscopy service, specialized nurses were available in 75 %. Fiberscopes were used only in 15 %. A mean of 10 +/- 12 (range: 0 - 160) bleeding cases/month were treated, 6 +/- 6 cases per month (60 %) were ulcer bleedings. Endoscopy was performed in 72 % immediately after stabilization but in all cases within 24 hours. The Forrest classification was used in 99 % whereas prognostic scores were applied only in 3 %. Forrest Ia,/Ib/IIa/IIb/IIc/III ulcers were indications for endoscopic therapy in 99 %/ 99 %/ 90 %/ 58 %/ 4 %/ 2 % respectively. Favoured initial treatment was injection (diluted epinephrine, mean volume 17 +/- 13 mL/lesion) followed by clipping. In re-bleedings, 93 % tried endoscopic treatment again. Scheduled re-endoscopy was performed in 63 %. PPI were used in 99.6 %, 85 % administered standard dose twice daily. PPI administration was changed from intravenous to oral with the end of fasting in nearly all hospitals. PPI administration schemes can be improved. Indications for Helicobacter pylori eradication followed rational principles. Medical and endoscopic treatment of bleeding ulcers reached a high standard, although some therapeutic strategies leave room for improvement. Bigger hospitals tend to be closer to the medical standard.
A Review of Optical NDT Technologies
Zhu, Yong-Kai; Tian, Gui-Yun; Lu, Rong-Sheng; Zhang, Hong
2011-01-01
Optical non-destructive testing (NDT) has gained more and more attention in recent years, mainly because of its non-destructive imaging characteristics with high precision and sensitivity. This paper provides a review of the main optical NDT technologies, including fibre optics, electronic speckle, infrared thermography, endoscopic and terahertz technology. Among them, fibre optics features easy integration and embedding, electronic speckle focuses on whole-field high precision detection, infrared thermography has unique advantages for tests of combined materials, endoscopic technology provides images of the internal surface of the object directly, and terahertz technology opens a new direction of internal NDT because of its excellent penetration capability to most of non-metallic materials. Typical engineering applications of these technologies are illustrated, with a brief introduction of the history and discussion of recent progress. PMID:22164045
Lim, Chul-Hyun; Cho, Young-Seok
2016-01-01
Nonampullary duodenal adenomas are relatively common in familial adenomatous polyposis (FAP), but nonampullary sporadic duodenal adenomas (SDAs) are rare. Emerging evidence shows that duodenal adenomas, regardless of their anatomic location and whether they are sporadic or FAP-related, share morphologic and molecular features with colorectal adenomas. The available data suggest that duodenal adenomas develop to duodenal adenocarcinomas via similar mechanisms. The optimal approach for management of duodenal adenomas remains to be determined. The techniques for endoscopic resection of duodenal adenoma include snare polypectomy, endoscopic mucosal resection (EMR), endoscopic submucosal dissection (ESD), and argon plasma coagulation ablation. EMR may facilitate removal of large duodenal polyps. Although several studies have reported cases of successful ESD for duodenal adenomas, the procedure is technically difficult to perform safely because of the anatomical properties of the duodenum. Although current clinical practice recommends endoscopic resection of all large duodenal adenomas in patients with FAP, endoscopic treatment is usually insufficient to guarantee a polyp-free duodenum. Surgery is indicated for FAP patients with severe polyposis or nonampullary SDAs or FAP-related polyps not amenable to endoscopic resection. Further studies are needed to develop newer endoscopic techniques to guide diagnostic and therapeutic decisions for future management of nonampullary duodenal adenomas. PMID:26811631
[The recent news in endoscopic surgery: a review of the literature and meta-analysis].
Klimenko, K É
2012-01-01
During a few recent years, endonasal surgery has become the principal tool for the operative treatment of many pathologies affecting the base of the skull. The present work was designed to estimate the possibilities of using endoscopic endonasal surgery to treat sinus and skull base lesions and illustrate the recent progress in the development of endoscopic equipment and instrumentation. The meta-analysis of the results of on-going research on the application of the endonasal endoscopic technology is described with the special emphasis on the plastic treatment of liquor fistulas, removal of juvenile nasopharyngeal angiofibromas, treatment of pathological changes in the clivial region and odontoid cervicomedullary junction.
Bell, Charreau S; Obstein, Keith L; Valdastri, Pietro
2013-11-01
Colorectal cancer is one of the leading causes of cancer-related deaths in the world, although it can be effectively treated if detected early. Teleoperated flexible endoscopes are an emerging technology to ease patient apprehension about the procedure, and subsequently increase compliance. Essential to teleoperation is robust feedback reflecting the change in pose (i.e., position and orientation) of the tip of the endoscope. The goal of this study is to first describe a novel image-based tracking system for teleoperated flexible endoscopes, and subsequently determine its viability in a clinical setting. The proposed approach leverages artificial neural networks (ANNs) to learn the mapping that links the optical flow between two sequential images to the change in the pose of the camera. Secondly, the study investigates for the first time how narrow band illumination (NBI) - today available in commercial gastrointestinal endoscopes - can be applied to enhance feature extraction, and quantify the effect of NBI and white light illumination (WLI), as well as their color information, on the strength of features extracted from the endoscopic camera stream. In order to provide the best features for the neural networks to learn the change in pose based on the image stream, we investigated two different imaging modalities - WLI and NBI - and we applied two different spatial partitions - lumen-centered and grid-based - to create descriptors used as input to the ANNs. An experiment was performed to compare the error of these four variations, measured in root mean square error (RMSE) from ground truth given by a robotic arm, to that of a commercial state-of-the-art magnetic tracker. The viability of this technique for a clinical setting was then tested using the four ANN variations, a magnetic tracker, and a commercial colonoscope. The trial was performed by an expert endoscopist (>2000 lifetime procedures) on a colonoscopy training model with porcine blood, and the RMSE of the ANN output was calculated with respect to the magnetic tracker readings. Using the image stream obtained from the commercial endoscope, the strength of features extracted was evaluated. In the first experiment, the best ANNs resulted from grid-based partitioning under WLI (2.42mm RMSE) for position, and from lumen-centered partitioning under NBI (1.69° RMSE) for rotation. By comparison, the performance of the tracker was 2.49mm RMSE in position and 0.89° RMSE in rotation. The trial with the commercial endoscope indicated that lumen-centered partitioning was the best overall, while NBI outperformed WLI in terms of illumination modality. The performance of lumen-centered partitioning with NBI was 1.03±0.8mm RMSE in positional degrees of freedom (DOF), and 1.26±0.98° RMSE in rotational DOF, while with WLI, the performance was 1.56±1.15mm RMSE in positional DOF and 2.45±1.90° RMSE in rotational DOF. Finally, the features extracted under NBI were found to be twice as strong as those extracted under WLI, but no significance in feature strengths was observed between a grayscale version of the image, and the red, blue, and green color channels. This work demonstrates that both WLI and NBI, combined with feature partitioning based on the anatomy of the colon, provide valid mechanisms for endoscopic camera pose estimation via image stream. Illumination provided by WLI and NBI produce ANNs with similar performance which are comparable to that of a state-of-the-art magnetic tracker. However, NBI produces features that are stronger than WLI, which enables more robust feature tracking, and better performance of the ANN in terms of accuracy. Thus, NBI with lumen-centered partitioning resulted the best approach among the different variations tested for vision-based pose estimation. The proposed approach takes advantage of components already available in commercial gastrointestinal endoscopes to provide accurate feedback about the motion of the tip of the endoscope. This solution may serve as an enabling technology for closed-loop control of teleoperated flexible endoscopes. Copyright © 2013 Elsevier B.V. All rights reserved.
Coblation-assisted endonasal endoscopic resection of juvenile nasopharyngeal angiofibroma.
Ye, L; Zhou, X; Li, J; Jin, J
2011-09-01
Juvenile nasopharyngeal angiofibroma may be successfully resected using endoscopic techniques. However, the use of coblation technology for such resection has not been described. This study aimed to document cases of Fisch class I juvenile nasopharyngeal angiofibroma with limited nasopharyngeal and nasal cavity extension, which were completely resected using an endoscopic coblation technique. We retrospectively studied 23 patients with juvenile nasopharyngeal angiofibroma who underwent resection with either traditional endoscopic instruments (n = 12) or coblation (n = 11). Intra-operative blood loss and overall operative time were recorded. The mean tumour resection time for coblation and traditional endoscopic instruments was 87 and 136 minutes, respectively (t = 9.962, p < 0.001). Mean intra-operative blood loss was 121 and 420 ml, respectively (t = 28.944, p < 0.001), a significant difference. Both techniques achieved complete tumour resection with minimal damage to adjacent tissues, and no recurrence in any patient. Coblation successfully achieves transnasal endoscopic resection of juvenile nasopharyngeal angiofibroma (Fisch class I), with good surgical margins and minimal blood loss.
Dangers in the Use of Staplers in Liver Surgery
Riga, Angela; Karanjia, Nariman
2007-01-01
The use of endoscopic vascular staplers has become common practice in recent years both in open and minimally invasive surgery. The technological advances, however, are not free of problems. In our practice, we have come across two cases where the Endopath ETS Flex 45 Endoscopic Articulating Linear Cutter failed with dangerous consequences. PMID:17999829
DOE Office of Scientific and Technical Information (OSTI.GOV)
Loffroy, Romaric, E-mail: romaric.loffroy@yahoo.fr; Rao, Pramod; Ota, Shinichi
2010-12-15
Acute nonvariceal upper gastrointestinal (UGI) hemorrhage is a frequent complication associated with significant morbidity and mortality. The most common cause of UGI bleeding is peptic ulcer disease, but the differential diagnosis is diverse and includes tumors; ischemia; gastritis; arteriovenous malformations, such as Dieulafoy lesions; Mallory-Weiss tears; trauma; and iatrogenic causes. Aggressive treatment with early endoscopic hemostasis is essential for a favorable outcome. However, severe bleeding despite conservative medical treatment or endoscopic intervention occurs in 5-10% of patients, requiring surgery or transcatheter arterial embolization. Surgical intervention is usually an expeditious and gratifying endeavor, but it can be associated with high operativemore » mortality rates. Endovascular management using superselective catheterization of the culprit vessel, < sandwich> occlusion, or blind embolization has emerged as an alternative to emergent operative intervention for high-risk patients and is now considered the first-line therapy for massive UGI bleeding refractory to endoscopic treatment. Indeed, many published studies have confirmed the feasibility of this approach and its high technical and clinical success rates, which range from 69 to 100% and from 63 to 97%, respectively, even if the choice of the best embolic agent among coils, cyanaocrylate glue, gelatin sponge, or calibrated particles remains a matter of debate. However, factors influencing clinical outcome, especially predictors of early rebleeding, are poorly understood, and few studies have addressed this issue. This review of the literature will attempt to define the role of embolotherapy for acute nonvariceal UGI hemorrhage that fails to respond to endoscopic hemostasis and to summarize data on factors predicting angiographic and embolization failure.« less
Acute gastric volvulus treated with laparoscopic reduction and percutaneous endoscopic gastrostomy.
Jeong, Sang-Ho; Ha, Chang-Youn; Lee, Young-Joon; Choi, Sang-Kyung; Hong, Soon-Chan; Jung, Eun-Jung; Ju, Young-Tae; Jeong, Chi-Young; Ha, Woo-Song
2013-07-01
Acute gastric volvulus requires emergency surgery, and a laparoscopic approach for both acute and chronic gastric volvulus was reported recently to give good results. The case of a 50-year-old patient with acute primary gastric volvulus who was treated by laparoscopic reduction and percutaneous endoscopic gastrostomy is described here. This approach seems to be feasible and safe for not only chronic gastric volvulus, but also acute gastric volvulus.
Kirsch, Andrew J; Arlen, Angela M
2014-09-01
Vesicoureteral reflux (VUR) is one of the most common urologic diagnoses affecting children, and optimal treatment requires an individualized approach that considers potential risks. Management options include observation with or without continuous antibiotic prophylaxis and surgical correction via endoscopic, open or laparoscopic/robotic approaches. Endoscopic correction of VUR is an outpatient procedure associated with decreased morbidity compared with ureteral reimplantation. The concept of ureteral hydrodistention and intraluminal submucosal injection (Hydrodistention Implantation Technique [HIT]) has led to improved success rates in eliminating VUR compared with the subureteral transurethral injection technique. Further modifications now include use of proximal and distal intraluminal injections (Double HIT) that result in coaptation of both the ureteral tunnel and orifice. Endoscopic injection of dextranomer/hyaluronic acid copolymer, via the HIT and Double HIT, has emerged as a highly successful, minimally invasive alternative to open surgical correction, with minimal associated morbidity.
Bae, Sam Y; Korniski, Ronald J; Shearn, Michael; Manohara, Harish M; Shahinian, Hrayr
2017-01-01
High-resolution three-dimensional (3-D) imaging (stereo imaging) by endoscopes in minimally invasive surgery, especially in space-constrained applications such as brain surgery, is one of the most desired capabilities. Such capability exists at larger than 4-mm overall diameters. We report the development of a stereo imaging endoscope of 4-mm maximum diameter, called Multiangle, Rear-Viewing Endoscopic Tool (MARVEL) that uses a single-lens system with complementary multibandpass filter (CMBF) technology to achieve 3-D imaging. In addition, the system is endowed with the capability to pan from side-to-side over an angle of [Formula: see text], which is another unique aspect of MARVEL for such a class of endoscopes. The design and construction of a single-lens, CMBF aperture camera with integrated illumination to generate 3-D images, and the actuation mechanism built into it is summarized.
NASA Astrophysics Data System (ADS)
Mao, Yamin; Jiang, Shixin; Ye, Jinzuo; An, Yu; Yang, Xin; Chi, Chongwei; Tian, Jie
2015-03-01
For clinical surgery, it is still a challenge to objectively determine tumor margins during surgery. With the development of medical imaging technology, fluorescence molecular imaging (FMI) method can provide real-time intraoperative tumor margin information. Furthermore, surgical navigation system based on FMI technology plays an important role for the aid of surgeons' precise tumor margin decision. However, detection depth is the most limitation exists in the FMI technique and the method convenient for either macro superficial detection or micro deep tissue detection is needed. In this study, we combined advantages of both open surgery and endoscopic imaging systems with FMI technology. Indocyanine green (ICG) experiments were performed to confirm the feasibility of fluorescence detection in our system. Then, the ICG signal was photographed in the detection area with our system. When the system connected with endoscope lens, the minimum quantity of ICG detected by our system was 0.195 ug. For aspect of C mount lens, the sensitivity of ICG detection with our system was 0.195ug. Our experiments results proved that it was feasible to detect fluorescence images with this combination method. Our system shows great potential in the clinical applications of precise dissection of various tumors
Endoscopic management of peripancreatic fluid collections.
Goyal, Jatinder; Ramesh, Jayapal
2015-07-01
Peripancreatic fluid collections are a well-known complication of pancreatitis and can vary from fluid-filled collections to entirely necrotic collections. Although most of the fluid-filled pseudocysts tend to resolve spontaneously with conservative management, intervention is necessary in symptomatic patients. Open surgery has been the traditional treatment modality of choice though endoscopic, laparoscopic and transcutaneous techniques offer alternative drainage approaches. During the last decade, improvement in endoscopic ultrasound technology has enabled real-time access and drainage of fluid collections that were previously not amenable to blind transmural drainage. This has initiated a trend towards use of this modality for treatment of pseudocysts. In this review, we have summarised the existing evidence for endoscopic drainage of peripancreatic fluid collections from published studies.
Modelling of a laser-pumped light source for endoscopic surgery
NASA Astrophysics Data System (ADS)
Nadeau, Valerie J.; Elson, Daniel S.; Hanna, George B.; Neil, Mark A. A.
2008-09-01
A white light source, based on illumination of a yellow phosphor with a fibre-coupled blue-violet diode laser, has been designed and built for use in endoscopic surgery. This narrow light probe can be integrated into a standard laparoscope or inserted into the patient separately via a needle. We present a Monte Carlo model of light scattering and phosphorescence within the phosphor/silicone matrix at the probe tip, and measurements of the colour, intensity, and uniformity of the illumination. Images obtained under illumination with this light source are also presented, demonstrating the improvement in illumination quality over existing endoscopic light sources. This new approach to endoscopic lighting has the advantages of compact design, improved ergonomics, and more uniform illumination in comparison with current technologies.
Shin, Milljae; Joh, Jae-Won
2016-01-01
Apart from noticeable improvements in surgical techniques and immunosuppressive agents, biliary complications remain the major causes of morbidity and mortality after living donor liver transplantation (LDLT). Bile leakage and stricture are the predominant complications. The reported incidence of biliary complications is 15%-40%, and these are known to occur more frequently in living donors than in deceased donors. Despite the absence of a confirmed therapeutic algorithm, many approaches have been used for treatment, including surgical, endoscopic, and percutaneous transhepatic techniques. In recent years, nonsurgical approaches have largely replaced reoperation. Among these, the endoscopic approach is currently the preferred initial treatment for patients who undergo duct-to-duct biliary reconstruction. Previously, endoscopic management was achieved most optimally through balloon dilatation and single or multiple stents placement. Recently, there have been significant developments in endoscopic devices, such as novel biliary stents, as well as advances in endoscopic technologies, including deep enteroscopy, the rendezvous technique, magnetic compression anastomosis, and direct cholangioscopy. These developments have resulted in almost all patients being managed by the endoscopic approach. Multiple recent publications suggest superior long-term results, with overall success rates ranging from 58% to 75%. This article summarizes the advances in endoscopic management of patients with biliary complications after LDLT. PMID:27468208
A wireless narrowband imaging chip for capsule endoscope.
Lan-Rong Dung; Yin-Yi Wu
2010-12-01
This paper presents a dual-mode capsule gastrointestinal endoscope device. An endoscope combined with a narrowband image (NBI), has been shown to be a superior diagnostic tool for early stage tissue neoplasms detection. Nevertheless, a wireless capsule endoscope with the narrowband imaging technology has not been presented in the market up to now. The narrowband image acquisition and power dissipation reduction are the main challenges of NBI capsule endoscope. In this paper, we present the first narrowband imaging capsule endoscope that can assist clinical doctors to effectively diagnose early gastrointestinal cancers, profited from our dedicated dual-mode complementary metal-oxide semiconductor (CMOS) sensor. The dedicated dual-mode CMOS sensor can offer white-light and narrowband images. Implementation results show that the proposed 512 × 512 CMOS sensor consumes only 2 mA at a 3-V power supply. The average current of the NBI capsule with an 8-Mb/s RF transmitter is nearly 7 ~ 8 mA that can continuously work for 6 ~ 8 h with two 1.5-V 80-mAh button batteries while the frame rate is 2 fps. Experimental results on backside mucosa of a human tongue and pig's small intestine showed that the wireless NBI capsule endoscope can significantly improve the image quality, compared with a commercial-of-the-shelf capsule endoscope for gastrointestinal tract diagnosis.
Confocal laser endomicroscopy in the "in vivo" histological diagnosis of the gastrointestinal tract.
De Palma, Giovanni D
2009-12-14
Recent technological advances in miniaturization have allowed for a confocal scanning microscope to be integrated into a conventional flexible endoscope, or into trans-endoscopic probes, a technique now known as confocal endomicroscopy or confocal laser endomicroscopy. This newly-developed technology has enabled endoscopists to collect real-time in vivo histological images or "virtual biopsies" of the gastrointestinal mucosa during endoscopy, and has stimulated significant interest in the application of this technique in clinical gastroenterology. This review aims to evaluate the current data on the technical aspects and the utility of this new technology in clinical gastroenterology and its potential impact in the future, particularly in the screening or surveillance of gastrointestinal neoplasia.
Modifications in endoscopic practice for pediatric patients.
Lightdale, Jenifer R; Acosta, Ruben; Shergill, Amandeep K; Chandrasekhara, Vinay; Chathadi, Krishnavel; Early, Dayna; Evans, John A; Fanelli, Robert D; Fisher, Deborah A; Fonkalsrud, Lisa; Hwang, Joo Ha; Kashab, Mouen; Muthusamy, V Raman; Pasha, Shabana; Saltzman, John R; Cash, Brooks D
2014-05-01
We recommend that endoscopy in children be performed by pediatric-trained endoscopists whenever possible. We recommend that adult-trained endoscopists coordinate their services with pediatricians and pediatric specialists when they are needed to perform endoscopic procedures in children. We recommend that endoscopy be performed within 24 hours in symptomatic pediatric patients with known or suspected ingestion of caustic substances. We recommend emergent foreign-body removal of esophageal button batteries, as well as 2 or more rare-earth neodymium magnets. We recommend that procedural and resuscitative equipment appropriate for pediatric use should be readily available during endoscopic procedures. We recommend that personnel trained specifically in pediatric life support and airway management be readily available during sedated procedures in children. We recommend the use of endoscopes smaller than 6 mm in diameter in infants and children weighing less than 10 kg. We recommend the use of standard adult duodenoscopes for performing ERCP in children who weigh at least 10 kg. We recommend the placement of 12F or 16F percutaneous endoscopic gastrostomy tubes in children who weigh less than 50 kg.
Role of transcatheter arterial embolization for massive bleeding from gastroduodenal ulcers
Loffroy, Romaric; Guiu, Boris
2009-01-01
Intractable bleeding from gastric and duodenal ulcers is associated with significant morbidity and mortality. Aggressive treatment with early endoscopic hemostasis is essential for a favourable outcome. In as many as 12%-17% of patients, endoscopy is either not available or unsuccessful. Endovascular therapy with selective catheterization of the culprit vessel and injection of embolic material has emerged as an alternative to emergent operative intervention in high-risk patients. There has not been a systematic literature review to assess the role for embolotherapy in the treatment of acute upper gastrointestinal bleeding from gastroduodenal ulcers after failed endoscopic hemostasis. Here, we present an overview of indications, techniques, and clinical outcomes after endovascular embolization of acute peptic-ulcer bleeding. Topics of particular relevance to technical and clinical success are also discussed. Our review shows that transcatheter arterial embolization is a safe alternative to surgery for massive gastroduodenal bleeding that is refractory to endoscopic treatment, can be performed with high technical and clinical success rates, and should be considered the salvage treatment of choice in patients at high surgical risk. PMID:20014452
Etiology of esophageal food impactions in children.
Hurtado, Christine Waasdorp; Furuta, Glenn T; Kramer, Robert E
2011-01-01
The aim of the study was to measure clinicopathological features of children presenting to a tertiary care emergency department with esophageal food impaction. A retrospective chart review of children with esophageal food impaction seen between January 1, 2005 and June 30, 2009, including all patients from age 1 month to 18 years with esophageal food impaction at a pediatric emergency department, was performed. Initial screening of International Classification of Disease, 9th Revision, discharge diagnosis identified 698 children with an esophageal foreign body. Of this group, 72 esophageal food impaction events were identified in 65 children (69% boys), 49 of whom required endoscopic intervention. Endoscopic appearances of the esophageal mucosa were abnormal in 40 (82%), revealing evidence of esophagitis (55%) or stricture (27%). Twenty-four of the subjects had biopsies taken at the time of endoscopy. Inflammation, described as increased eosinophils, basilar hyperplasia, rete peg elongation, and/or microabscess, was present in 76% of mucosal samples. Follow-up endoscopy in 12 children identified an etiology in 9, five of whom were found to have eosinophilic esophagitis. The majority of children with esophageal food impaction who underwent endoscopic evaluation and biopsy have an underlying potentially treatable cause. We therefore recommend that all of the children with esophageal food impaction have mucosal biopsies at the time of endoscopic disimpaction with appropriate follow-up to allow for diagnosis and management of the underlying etiology.
Comparison of intravenous pantoprazole with intravenous ranitidine in peptic ulcer bleeding.
Demetrashvili, Z M; Lashkhi, I M; Ekaladze, E N; Kamkamidze, G K
2013-10-01
Following successful endoscopic therapy in patients with peptic ulcer bleeding, rebleeding occurs in 4% to 30% of cases. Rebleeding remains the most important determinant of poor prognosis. The aim of our study is to compare the efficacy of intravenous pantoprazole and ranitidine for prevention of rebleeding of peptic ulcers following initial endoscopic hemostasis. In our study patients who had gastric or duodenal ulcers with bleeding received combined endoscopy therapy with injection of epinephrine and thermocoagulation. Patients with initial hemostasis were randomly assigned to two groups. One group (45 patients) was treated with intravenous pantoprazole, with an initial dose of 40 mg and subsequently with 40 mg every twelve hours during the first three days, followed by 40 mg a day orally. The other group (44 patients) was treated with intravenous ranitidine, with an initial dose of 50 mg and subsequently every eight hours during the first three days, followed by 150 mg ranitidine every 12 h. In all case of rebleeding repeated endoscopy was performed. One patient (2,2%) had rebleeding in pantoprazole group. Bleeding could not be blocked by repeated endoscopic intervention, thus the patient underwent emergency surgery. 6 patients (13,6%) from ranitidine group had recurrence of bleeding. Repeated endoscopy was performed in all these patients: bleeding was stopped in 3 cases endoscopically, other 3 patients were surgically treated urgently as endoscopic hemostasis was not successful. None of the patients died of uncontrolled rebleeding. The frequency of rebleeding was significantly low in the group of pantoprazole compared to ranitidine group (2,2% vs 13,6% P=0,046). There were no statistically significant differences between the groups with regard to need for emergency surgery (2,2% vs 6,8%), the length of hospital stay (6,7±3,3 vs 7,4±4,3 d) and mortality (0%vs 0%). After endoscopic treatment of bleeding peptic ulcers, intravenous pantoprazole is more effective than ranitidine for the prevention of rebleeding.
Ko, Weon Jin; An, Pyeong; Ko, Kwang Hyun; Hahm, Ki Baik; Hong, Sung Pyo
2015-01-01
Arising from human curiosity in terms of the desire to look within the human body, endoscopy has undergone significant advances in modern medicine. Direct visualization of the gastrointestinal (GI) tract by traditional endoscopy was first introduced over 50 years ago, after which fairly rapid advancement from rigid esophagogastric scopes to flexible scopes and high definition videoscopes has occurred. In an effort towards early detection of precancerous lesions in the GI tract, several high-technology imaging scopes have been developed, including narrow band imaging, autofocus imaging, magnified endoscopy, and confocal microendoscopy. However, these modern developments have resulted in fundamental imaging technology being skewed towards red-green-blue and this technology has obscured the advantages of other endoscope techniques. In this review article, we have described the importance of image quality analysis using a survey to consider the diversity of endoscope system selection in order to better achieve diagnostic and therapeutic goals. The ultimate aims can be achieved through the adoption of modern endoscopy systems that obtain high image quality. PMID:26473119
[Acute asthma attacks introduced by anesthesia before nasal endoscopic surgery].
Lü, Xiaofei; Han, Demin; Zhou, Bing; Ding, Bin
2004-05-01
In order to pay our attention to the perioperative treatment before nasal endoscopic surgery. Three patients with asthma accompanied chronic sinusitis were analyzed systemically, who had undergone acute attacks of asthma introduced by anesthesia. Anesthetic drugs and instruments can lead to acute attacks of asthma, because sinusitis with asthma means allergic airway inflammation, broncho-hyperreactivity and lower compensatory pulmonary function. Then all of the 3 cases had missed the preoperative treatment. Anesthetic drugs and instruments can lead to acute attacks of asthma. The perioperative treatment before nasal endoscopic surgery is very important for the prevention of the occurrences of this severe complication. Except emergency, the operation should be can celled for avoiding the acute attack of asthma introduced by anesthesia.
[Tracheotomy-endoscop for dilatational percutaneous tracheotomy (TED)].
Klemm, Eckart
2006-09-01
While surgical tracheotomies are currently performed using state-of-the-art operative techniques, percutaneous dilatational tracheostomy (PDT) is in a rapidly evolving state with regard to its technology and the number of techniques available. This has resulted in a range of new complications that are difficult to quantify on a scientific basis, given the fact that more than half of the patients who are tracheotomized in intensive care units die from their underlying disease. The new Tracheotomy Endoscope (TED) is designed to help prevent serious complications in dilatational tracheotomies and facilitate their management. The endoscope has been specifically adapted to meet the require-ments of percutaneous dilatational tracheotomies. It is fully compatible with all current techniques of PDT. The method is easy to learn. The percutaneous dilatational tracheotomy with the Tracheotomy Endoscope is a seven-step procedure: Advantages of the Tracheotomy Endoscope: Injuries to the posterior tracheal wall ar impossible (tracheoesophageal fistulas, pneumothorax). Minor bleeding sites on the tracheal mucosa can be controlled with a specially curved suction-coagulation tube introudeced through the Tracheotomy Endoscope. In cases with heavy bleeding and a risk of aspiration, the rigid indwelling Tracheotomy Endoscope provides a secure route for reintubating the patient with a cuffed endotracheal tube. It also allows for rapid conversion to an open surgical procedure if necessary. All the parts are easy to clean and are autoclavable. This type of endoscopically guided PDT creates an optimal link between the specialties of intensive care medicine and otorhinolaryngology. The Tracheotomy Endoscope (TED) increases the standard of safety in PDT.
Technological innovations in tissue removal during rhinologic surgery.
Sindwani, Raj; Manz, Ryan
2012-01-01
The modern rhinologist has a wide variety of technological innovations at his/her disposal for the removal of soft tissue and bone during endoscopic surgery. We identified and critically evaluated four leading tissue removal technologies that have impacted, or are poised to impact, rhinological surgery. A literature review was conducted. Technological functions, strengths and limitations of microdebriders, radio frequency ablation, endoscopic drills, and ultrasonic aspirators were explored. The primary drawback of powered instruments continues to be the higher costs associated with their use, and their main advantage is the ability to accomplish multiple functions such as tissue removal, suction, and irrigation, all with one tool. The effective and safe use of any powered instrument requires an intimate understanding of its function, capabilities, and limitations. Powered instrumentation continues to play a significant and evolving role in soft tissue and bone removal during rhinologic surgery.
Advanced shape tracking to improve flexible endoscopic diagnostics
NASA Astrophysics Data System (ADS)
Cao, Caroline G. L.; Wong, Peter Y.; Lilge, Lothar; Gavalis, Robb M.; Xing, Hua; Zamarripa, Nate
2008-03-01
Colonoscopy is the gold standard for screening for inflammatory bowel disease and colorectal cancer. Flexible endoscopes are difficult to manipulate, especially in the distensible and tortuous colon, sometimes leading to disorientation during the procedure and missed diagnosis of lesions. Our goal is to design a navigational aid to guide colonoscopies, presenting a three dimensional representation of the endoscope in real-time. Therefore, a flexible sensor that can track the position and shape of the entire length of the endoscope is needed. We describe a novel shape-tracking technology utilizing a single modified optical fiber. By embedding fluorophores in the buffer of the fiber, we demonstrated a relationship between fluorescence intensity and fiber curvature. As much as a 40% increase in fluorescence intensity was achieved when the fiber's local bend radius decreased from 58 mm to 11 mm. This approach allows for the construction of a three-dimensional shape tracker that is small enough to be easily inserted into the biopsy channel of current endoscopes.
Barrett's esophagus: endoscopic treatments II
Greenwald, Bruce D.; Lightdale, Charles J.; Abrams, Julian A.; Horwhat, John D.; Chuttani, Ram; Komanduri, Srinadh; Upton, Melissa P.; Appelman, Henry D.; Shields, Helen M.; Shaheen, Nicholas J.; Sontag, Stephen J.
2013-01-01
The following on endoscopic treatments of Barrett's esophagus includes commentaries on animal experiments on cryotherapy; indications for cryotherapy, choice of dosimetry, number of sessions, and role in Barrett's esophagus and adenocarcinoma; recent technical developments of RFA technology and long-term effects; the comparative effects of diverse ablation procedures and the rate of recurrence following treatment; and the indications for treatment of dysplasia and the role of radiofrequency ablation. PMID:21950812
Computer-aided decision support systems for endoscopy in the gastrointestinal tract: a review.
Liedlgruber, Michael; Uhl, Andreas
2011-01-01
Today, medical endoscopy is a widely used procedure to inspect the inner cavities of the human body. The advent of endoscopic imaging techniques-allowing the acquisition of images or videos-created the possibility for the development of the whole new branch of computer-aided decision support systems. Such systems aim at helping physicians to identify possibly malignant abnormalities more accurately. At the beginning of this paper, we give a brief introduction to the history of endoscopy, followed by introducing the main types of endoscopes which emerged so far (flexible endoscope, wireless capsule endoscope, and confocal laser endomicroscope). We then give a brief introduction to computer-aided decision support systems specifically targeted at endoscopy in the gastrointestinal tract. Then we present general facts and figures concerning computer-aided decision support systems and summarize work specifically targeted at computer-aided decision support in the gastrointestinal tract. This summary is followed by a discussion of some common issues concerning the approaches reviewed and suggestions of possible ways to resolve them.
New operational technology of intrauterine ventilation the fetus lungs by breathing gas
NASA Astrophysics Data System (ADS)
Urakov, A. L.; Nikityuk, D. B.; Urakova, N. A.; Kasankin, A. A.; Chernova, L. V.; Dementiev, V. B.
2015-11-01
New operational technology for elimination intrauterine hypoxia and asphyxia of the fetus using endoscopic artificial ventilation lungs by respiratory gas was developed. For intrauterine ventilation of fetal lung it is proposed to enter into the uterus a special breathing mask and wear it on the head of the fetus using the original endoscopic technology. The breathing mask, developed by us is connected with external breathing apparatus with a hose. The device is called "intrauterine aqualung". Intrauterine aqualung includes a ventilator and breathing circuit with a special fold-out breathing mask that is put on inside the uterus on the head of fetus like a mesh hat. Controlled by ultrasound the technology of the introduction of the mask inside of the uterus through the natural opening in the cervix and technology of putting on the respiratory mask on the head of the fetus with its head previa were developed. The technology intrauterine ventilation of the fetus lungs by respiratory gas was developed.
Loffroy, Romaric; Guiu, Boris; Mezzetta, Lise; Minello, Anne; Michiels, Christophe; Jouve, Jean-Louis; Cheynel, Nicolas; Rat, Patrick; Cercueil, Jean-Pierre; Krausé, Denis
2009-01-01
BACKGROUND AND AIM: Severe bleeding from gastrointestinal ulcers is a life-threatening event that is difficult to manage when endoscopic treatment fails. Transcatheter embolization has been suggested as an alternative treatment in this situation. The present study reports on the efficacy and long-term outcomes of transcatheter embolization after failed endoscopic treatments were assessed in high-operative-risk patients. METHODS: A retrospective review of 60 consecutive emergency embolization procedures in hemodynamically unstable patients (41 men, 19 women; mean [±SD] age 69.4±15 years) was conducted. Patients were referred for selective angiography between 1999 and 2008 after failed endoscopic treatment of massive bleeding from gastrointestinal ulcers. Mean follow-up was 22 months. RESULTS: Embolization was feasible and successful in 57 patients. Sandwich coiling of the gastroduodenal artery was used in 34 patients, and superselective occlusion of the terminal feeding artery (with glue, coils or gelatin particles) was used in 23 patients. Early rebleeding occurred in 16 patients and was managed with endoscopy (n=8), reembolization (n=3) or surgery (n=5). No major embolization-related complications occurred. Sixteen patients died within 30 days after embolization (including three who died from rebleeding) and 11 died thereafter. No late bleeding recurrences were reported. CONCLUSIONS: Selective angiographic embolization is safe and effective for controlling life-threatening bleeding from gastroduodenal ulcers. The procedure usually obviates the need for emergency surgery in these high-risk patients. Survival depends chiefly on underlying conditions. PMID:19214287
Esquenazi, Yoshua; Essayed, Walid I; Singh, Harminder; Mauer, Elizabeth; Ahmed, Mudassir; Christos, Paul J; Schwartz, Theodore H
2017-05-01
Surgery for recurrent/residual pituitary adenomas is increasingly being performed through endoscopic surgery. Whether this new technology has altered the indications and outcomes of surgery is unknown. We conducted a systematic review and meta-analysis of published studies to compare the indications and outcomes between microscopic and endoscopic approaches. A PubMed search was conducted (1985-2015) to identify surgical series of endoscopic endonasal and microscopic transsphenoidal resection of residual or recurrent pituitary adenomas. Data were extracted regarding tumor characteristics, surgical treatment, extent of resection, endocrine remission, visual outcome, and complications. Twenty-one studies met inclusion criteria. A total of 292 patients were in the endoscopic group, and 648 patients were in the microscopic group. Endoscopic cases were more likely nonfunctional (P < 0.001) macroadenomas (P < 0.001) with higher rates of cavernous sinus invasion (P = 0.012). The pooled rate of gross total tumor resection was 53.5% for the endoscopic group and 46.6% for the microscopic group. Endocrine remission was achieved in 53.0% and 46.7% of patients, and visual improvement occurred in 73.2% and 49.6% for the endoscopic and microscopic groups. Cerebrospinal fluid leak and pituitary insufficiency were higher in the endoscopic group. This meta-analysis indicates that the use of the endoscope to reoperate on residual or recurrent adenomas has only led to modest increases in resection rates. However, larger more complex cases are being tackled, so direct comparisons are misleading. The most dramatic change has been in visual improvement along with modest increases in risk. Reoperation for recurrent or residual adenomas is a safe and effective treatment option. Copyright © 2017 Elsevier Inc. All rights reserved.
Russell, Jonathon; Anuwong, Angkoon; Dionigi, Gianlorenzo; Inabnet, William B; Kim, Hoon Yub; Randolph, Gregory W; Richmon, Jeremy D; Tufano, Ralph P
2018-05-23
Transoral endoscopic thyroidectomy vestibular approach (TOETVA) is a new approach to the central neck that avoids an anterior cervical incision. This approach can be performed with endoscopic or robotic assistance and offers access to the bilateral central neck. It has been completed safely in both North American and, even more extensively, international populations. With any new technology or approach, complications during the learning curve, expense, instrument limitations, and overall safety may affect its ultimate adoption and utility. To ensure patient safety, it is imperative to define steps that should be considered by any surgeon or group before adoption of this new approach.
Low Power Transmitter for Wireless Capsule Endoscope
NASA Astrophysics Data System (ADS)
Lioe, D. X.; Shafie, S.; Ramiah, H.; Sulaiman, N.; Halin, I. A.
2013-04-01
This paper presents the transmitter circuit designed for the application of wireless capsule endoscope to overcome the limitation of conventional endoscope. The design is performed using CMOS 0.13 μm technology. The transmitter is designed to operate at centre frequency of 433.92 MHz, which is one of the ISM band. Active mixer and ring oscillator made up the transmitter and it consumes 1.57 mA of current using a supply voltage of 1.2 V, brings the dc power consumption of the transmitter to be 1.88 mW. Data rate of 3.5 Mbps ensure it can transmit high quality medical imaging.
The Role of Adjunct Imaging in Endoscopic Detection of Dysplasia in Barrett's Esophagus.
Kandel, Pujan; Wallace, Michael B
2017-07-01
Advances in imaging technologies have demonstrated promise in early detection of dysplasia and cancer in Barrett's esophagus (BE). Optical chromoendoscopy, dye-based chromoendoscopy, and novel technologies have provided the opportunity to visualize the cellular and subcellular structures. Only narrow-band imaging and acetic acid chromoendoscopy have reached benchmarks for clinical use. Volumetric laser endomicroscopy and molecular imaging are not established for routine use. Best practice in management of BE should be focused on careful endoscopic examination, resection, or ablation of the entire abnormal lesion, as well as the use of available imaging technique that has good diagnostic accuracy. Copyright © 2017 Elsevier Inc. All rights reserved.
Hodaj, Irgen; Kutlay, Murat; Gonul, Engin; Solmaz, Ilker; Tehli, Ozkan; Temiz, Caglar; Kural, Cahit; Daneyemez, Mehmet K; Izci, Yusuf
2014-01-01
We aimed to show the effects of neuronavigation and intraoperative imaging systems on the surgical outcomes of orbital tumors. Seventeen patients who underwent surgical treatment for orbital tumors by transcranial and transnasal approaches between 2008 and 2013 were analyzed retrospectively. Twelve of them were male and 5 were female. The mean age was 41.6 years. Neuronavigation systems were used in all cases. Four patients were operated using intraoperative imaging systems. The transcranial approach was used in 9 (53%) patients, endoscopic medial orbital approach in 4 (23.5%), endoscopic inferolateral approach in 1 (6%), cranioorbitozygomatic approach in 1, lateral approach in 1, and the combined (medial endoscopic and lateral) approach in 1 patients. Total resection was achieved in 5 patients, gross total excision in 2, subtotal in 9 and partial in 1 patients. Modern technology has made a significant contribution to the treatment of orbital tumors. Although technological equipments facilitate the excision of tumors, the level of resection is mainly determined by the nature of tumor and adhesion to the adjacent neurovascular structures. It should not be forgotten that advanced technology never replaces a good anatomical knowledge and surgical experience, but has a complementary role.
Movila, Alexandru; Kajiya, Mikihito; Wisitrasameewong, Wichaya; Stashenko, Philip; Vardar-Sengul, Saynur; Hernandez, Maria; Thomas Temple, H; Kawai, Toshihisa
2018-06-01
We report a novel method for in situ imaging of microvascular permeability in inflamed gingival tissue, using state-of-the-art Cellvizio™ intravital endoscopic technology and a mouse model of ligature-induced periodontitis. The silk ligature was first placed at the upper left second molar. Seven days later, the ligature was removed, and the animals were intravenously injected with Evans blue. Evans blue dye, which selectively binds to blood albumin, was used to monitor the level of inflammation by monitoring vascular permeability in control non-diseased and ligature-induced experimental periodontitis tissue. More specifically, leakage of Evans blue-bound albumin from the micro-capillary to connective tissue indicates the state of inflammation occurring in the specific site. Evans blue leakage from blood vessels was imaged in situ by directly attaching the endoscope (mini Z tip) of the Cellvizio™ system to the gingival tissue without any surgical incision. Evans blue emission intensity was significantly elevated in gingiva of periodontitis lesions, but not control non-ligature placed gingiva, indicating that this technology can be used as a potential minimally invasive diagnostic tool to monitor the level of inflammation at the periodontal disease site. Copyright © 2018 Elsevier B.V. All rights reserved.
Endoscopic and laparoscopic treatment of gastroesophageal reflux.
Watson, David I; Immanuel, Arul
2010-04-01
Gastroesophageal reflux is extremely common in Western countries. For selected patients, there is an established role for the surgical treatment of reflux, and possibly an emerging role for endoscopic antireflux procedures. Randomized trials have compared medical versus surgical management, laparoscopic versus open surgery and partial versus total fundoplications. However, the evidence base for endoscopic procedures is limited to some small sham-controlled studies, and cohort studies with short-term follow-up. Laparoscopic fundoplication has been shown to be an effective antireflux operation. It facilitates quicker convalescence and is associated with fewer complications, but has a similar longer term outcome compared with open antireflux surgery. In most randomized trials, antireflux surgery achieves at least as good control of reflux as medical therapy, and these studies support a wider application of surgery for the treatment of moderate-to-severe reflux. Laparoscopic partial fundoplication is an effective surgical procedure with fewer side effects, and it may achieve high rates of patient satisfaction at late follow-up. Many of the early endoscopic antireflux procedures have failed to achieve effective reflux control, and they have been withdrawn from the market. Newer procedures have the potential to fashion a surgical fundoplication. However, at present there is insufficient evidence to establish the safety and efficacy of endoscopic procedures for the treatment of gastroesophageal reflux, and no endoscopic procedure has achieved equivalent reflux control to that achieved by surgical fundoplication.
Funk, S E; Reaven, N L
2014-04-01
The use of flexible endoscopes is growing rapidly around the world. Dominant approaches to high-level disinfection among resource-constrained countries include fully manual cleaning and disinfection and the use of automated endoscope reprocessors (AERs). Suboptimal reprocessing at any step can potentially lead to contamination, with consequences to patients and healthcare systems. To compare the potential results of guideline-recommended AERs to manual disinfection along three dimensions - productivity, need for endoscope repair, and infection transmission risk in India, China, and Russia. Financial modelling using data from peer-reviewed published literature and country-specific market research. In countries where revenue can be gained through productivity improvements, conversion to automated reprocessing has a positive direct impact on financial performance, paying back the capital investment within 14 months in China and seven months in Russia. In India, AER-generated savings and revenue offset nearly all of the additional operating costs needed to support automated reprocessing. Among endoscopy facilities in India and China, current survey-reported practices in endoscope reprocessing using manual soaking may place patients at risk of exposure to pathogens leading to infections. Conversion from manual soak to use of AERs, as recommended by the World Gastroenterology Organization, may generate cost and revenue offsets that could produce direct financial gains for some endoscopy units in Russia and China. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.
Diagnosis and Management of High Risk Group for Gastric Cancer
Yoon, Hyuk; Kim, Nayoung
2015-01-01
Gastric cancer is associated with high morbidity and mortality worldwide. To reduce the socioeconomic burden related to gastric cancer, it is very important to identify and manage high risk group for gastric cancer. In this review, we describe the general risk factors for gastric cancer and define high risk group for gastric cancer. We discuss strategies for the effective management of patients for the prevention and early detection of gastric cancer. Atrophic gastritis (AG) and intestinal metaplasia (IM) are the most significant risk factors for gastric cancer. Therefore, the accurate selection of individuals with AG and IM may be a key strategy for the prevention and/or early detection of gastric cancer. Although endoscopic evaluation using enhanced technologies such as narrow band imaging-magnification, the serum pepsinogen test, Helicobacter pylori serology, and trefoil factor 3 have been evaluated, a gold standard method to accurately select individuals with AG and IM has not emerged. In terms of managing patients at high risk of gastric cancer, it remains uncertain whether H. pylori eradication reverses and/or prevents the progression of AG and IM. Although endoscopic surveillance in high risk patients is expected to be beneficial, further prospective studies in large populations are needed to determine the optimal surveillance interval. PMID:25547086
Rathmayer, Markus; Heinlein, Wolfgang; Reiß, Claudia; Albert, Jörg G; Akoglu, Bora; Braun, Martin; Brechmann, Thorsten; Gölder, Stefan K; Lankisch, Tim; Messmann, Helmut; Schneider, Arne; Wagner, Martin; Dollhopf, Markus; Gundling, Felix; Röhling, Michael; Haag, Cornelie; Dohle, Ines; Werner, Sven; Lammert, Frank; Fleßa, Steffen; Wilke, Michael H; Schepp, Wolfgang; Lerch, Markus M
2017-10-01
Background In the German hospital reimbursement system (G-DRG) endoscopic procedures are listed in cost center 8. For reimbursement between hospital departments and external providers outdated or incomplete catalogues (e. g. DKG-NT, GOÄ) have remained in use. We have assessed the cost for endoscopic procedures in the G-DRG-system. Methods To assess the cost of endoscopic procedures 74 hospitals, annual providers of cost-data to the Institute for the Hospital Remuneration System (InEK) made their data (2011 - 2015; § 21 KHEntgG) available to the German-Society-of-Gastroenterology (DGVS) in anonymized form (4873 809 case-data-sets). Using cases with exactly one endoscopic procedure (n = 274 186) average costs over 5 years were calculated for 46 endoscopic procedure-tiers. Results Robust mean endoscopy costs ranged from 230.56 € for gastroscopy (144 666 cases), 276.23 € (n = 32 294) for a simple colonoscopy, to 844.07 € (n = 10 150) for ERCP with papillotomy and plastic stent insertion and 1602.37 € (n = 967) for ERCP with a self-expanding metal stent. Higher costs, specifically for complex procedures, were identified for University Hospitals. Discussion For the first time this catalogue for endoscopic procedure-tiers, based on § 21 KHEntgG data-sets from 74 InEK-calculating hospitals, permits a realistic assessment of endoscopy costs in German hospitals. The higher costs in university hospitals are likely due to referral bias for complex cases and emergency interventions. For 46 endoscopic procedure-tiers an objective cost-allocation within the G-DRG system is now possible. By international comparison the costs of endoscopic procedures in Germany are low, due to either greater efficiency, lower personnel allocation or incomplete documentation of the real expenses. © Georg Thieme Verlag KG Stuttgart · New York.
Aoki, Hisae; Yamashita, Hiromasa; Mori, Toshiyuki; Fukuyo, Tsuneo; Chiba, Toshio
2014-11-01
We developed a new ultrahigh-sensitive CMOS camera using a specific sensor that has a wide range of spectral sensitivity characteristics. The objective of this study is to present our updated endoscopic technology that has successfully integrated two innovative functions; ultrasensitive imaging as well as advanced fluorescent viewing. Two different experiments were conducted. One was carried out to evaluate the function of the ultrahigh-sensitive camera. The other was to test the availability of the newly developed sensor and its performance as a fluorescence endoscope. In both studies, the distance from the endoscopic tip to the target was varied and those endoscopic images in each setting were taken for further comparison. In the first experiment, the 3-CCD camera failed to display the clear images under low illumination, and the target was hardly seen. In contrast, the CMOS camera was able to display the targets regardless of the camera-target distance under low illumination. Under high illumination, imaging quality given by both cameras was quite alike. In the second experiment as a fluorescence endoscope, the CMOS camera was capable of clearly showing the fluorescent-activated organs. The ultrahigh sensitivity CMOS HD endoscopic camera is expected to provide us with clear images under low illumination in addition to the fluorescent images under high illumination in the field of laparoscopic surgery.
Micro-nano-biosystems: An overview of European research.
Lymberis, Andreas
2010-06-01
New developments in science, technologies and applications are blurring the boundaries between information and communications technology (ICT), micro-nano systems and life sciences, e.g. through miniaturisation and the ability to manipulate matter at the atomic scale and to interface live and man-made systems. Interdisciplinary research towards integrated systems and their applications based on emerging convergence of information & communication technologies, micro-nano and bio technologies is expected to have a direct influence on healthcare, ageing population and well being. Micro-Nano-Bio Systems (MNBS) research and development activities under the European Union's R&D Programs, Information & Communication Technologies priority address miniaturised, smart and integrated systems for in-vitro testing e.g. lab-on-chips and systems interacting with the human e.g. autonomous implants, endoscopic capsules and robotics for minimally invasive surgery. The MNBS group involves hundreds of key public and private international organisations working on system development and validation in diverse applications such as cancer detection and therapy follow-up, minimally invasive surgery, capsular endocsopy, wearable biochemical monitoring and repairing of vital functions with active implant devices. The paper presents MNBS rationale and activities, discusses key research and innovation challenges and proposes R&D directions to achieve the expected impact on healthcare and quality of life.
2010-01-01
Background Analysis of gene expression and gene mutation may add information to be different from ordinary pathological tissue diagnosis. Since samples obtained endoscopically are very small, it is desired that more sensitive technology is developed for gene analysis. We investigated whether gene expression and gene mutation analysis by newly developed ultra-sensitive three-dimensional (3D) microarray is possible using small amount samples from endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) specimens and pancreatic juices. Methods Small amount samples from 17 EUS-FNA specimens and 16 pancreatic juices were obtained. After nucleic acid extraction, the samples were amplified with labeling and analyzed by the 3D microarray. Results The analyzable rate with the microarray was 46% (6/13) in EUS-FNA specimens of RNAlater® storage, and RNA degradations were observed in all the samples of frozen storage. In pancreatic juices, the analyzable rate was 67% (4/6) in frozen storage samples and 20% (2/10) in RNAlater® storage. EUS-FNA specimens were classified into cancer and non-cancer by gene expression analysis and K-ras codon 12 mutations were also detected using the 3D microarray. Conclusions Gene analysis from small amount samples obtained endoscopically was possible by newly developed 3D microarray technology. High quality RNA from EUS-FNA samples were obtained and remained in good condition only using RNA stabilizer. In contrast, high quality RNA from pancreatic juice samples were obtained only in frozen storage without RNA stabilizer. PMID:20416107
Progress in molecular imaging in endoscopy and endomicroscopy for cancer imaging
Khondee, Supang; Wang, Thomas D.
2014-01-01
Imaging is an essential tool for effective cancer management. Endoscopes are important medical instruments for performing in vivo imaging in hollow organs. Early detection of cancer can be achieved with surveillance using endoscopy, and has been shown to reduce mortality and to improve outcomes. Recently, great advancements have been made in endoscopic instruments, including new developments in optical designs, light sources, optical fibers, miniature scanners, and multimodal systems, allowing for improved resolution, greater tissue penetration, and multispectral imaging. In addition, progress has been made in the development of highly-specific optical probes, allowing for improved specificity for molecular targets. Integration of these new endoscopic instruments with molecular probes provides a unique opportunity for significantly improving patient outcomes and has potential to further improve early detection, image guided therapy, targeted therapy, and personalized medicine. This work summarizes current and evolving endoscopic technologies, and provides an overview of various promising optical molecular probes. PMID:23502247
ERCP (Endoscopic Retrograde Cholangiopancreatography)
... Process Research Training & Career Development Funded Grants & Grant History Research Resources Research at NIDDK Technology Advancement & Transfer Meetings & Workshops Health Information Diabetes Digestive ...
NASA Astrophysics Data System (ADS)
Bouma, Henri; van der Mark, Wannes; Eendebak, Pieter T.; Landsmeer, Sander H.; van Eekeren, Adam W. M.; ter Haar, Frank B.; Wieringa, F. Pieter; van Basten, Jean-Paul
2012-06-01
Compared to open surgery, minimal invasive surgery offers reduced trauma and faster recovery. However, lack of direct view limits space perception. Stereo-endoscopy improves depth perception, but is still restricted to the direct endoscopic field-of-view. We describe a novel technology that reconstructs 3D-panoramas from endoscopic video streams providing a much wider cumulative overview. The method is compatible with any endoscope. We demonstrate that it is possible to generate photorealistic 3D-environments from mono- and stereoscopic endoscopy. The resulting 3D-reconstructions can be directly applied in simulators and e-learning. Extended to real-time processing, the method looks promising for telesurgery or other remote vision-guided tasks.
Reconstruction, Enhancement, Visualization, and Ergonomic Assessment for Laparoscopic Surgery
2007-02-01
support and upgrade of the REVEAL display system and tool suite in the University of Maryland Medical Center’s Simulation Center, (2) stereo video display...technology deployment, (3) stereo probe calibration benchmarks and support tools , (4) the production of research media, (5) baseline results from...endoscope can be used to generate a stereoscopic view for a surgeon, as with the DaVinci robot in use today. In order to use such an endoscope for
Schwaitzberg, Steven D; Dorozhkin, Denis; Sankaranarayanan, Ganesh; Matthes, Kai; Jones, Daniel B; De, Suvranu
2016-01-01
A virtual translumenal endoscopic surgical trainer (VTEST) is being developed to accelerate the development of natural orifice translumenal endoscopic surgery (NOTES) procedures and devices in a safe and risk-free environment. For a rapidly developing field such as NOTES, a needs analysis must be conducted regularly to discover emerging research trends and areas of potential high impact for a virtual simulator. This paper presents a survey-based study which follows a similar study conducted by this group in 2011 (Sankaranarayanan et al. in Surg Endosc 27:1607-1616, 2013). A 32-point questionnaire was distributed at the 2012 Natural Orifice Surgery Consortium for Assessment and Research annual meeting. These data were subsequently augmented by an identical online survey, targeted at the members of the American Society for Gastrointestinal Endoscopy and the Society of American Gastrointestinal and Endoscopic Surgeons, and analyzed. Twenty-eight NOTES experts participated in the 2012 study. Cholecystectomy (CE) procedure remained the most commonly performed NOTES technique, with 18 positive responses (64%). In contrast to 2011, the popularity of the NOTES appendectomy (AE) was significantly lower, with only 2 (7%) instances (CE vs. AE, p < 0.001), while the number of peroral endoscopic myotomy (POEM, PE) cases had increased significantly, with 11 (39%) positive responses, respectively (PE vs. AE, p = 0.013). Strong preference toward hybrid rather than pure NOTES techniques (82 vs. 11%, p < 0.001) was also expressed. Other responses were similar to those in the 2011 study, with the VTEST™ utility in developing and testing new techniques and instruments ranked particularly high. Based on the results of this study, a decision was made to focus exclusively on the transvaginal hybrid NOTES cholecystectomy procedure, including both rigid and flexible scope techniques. The importance of developing a virtual NOTES simulator was reaffirmed, with POEM identified as a promising candidate for future simulator development.
Sharaiha, Reem Z; Kumta, Nikhil A; DeFilippis, Ersilia M; Dimaio, Christopher J; Gonzalez, Susana; Gonda, Tamas; Rogart, Jason; Siddiqui, Ali; Berg, Paul S; Samuels, Paul; Miller, Larry; Khashab, Mouen A; Saxena, Payal; Gaidhane, Monica R; Tyberg, Amy; Teixeira, Julio; Widmer, Jessica; Kedia, Prashant; Loren, David; Kahaleh, Michel; Sethi, Amrita
2016-01-01
To describe a multicenter experience using an endoscopic suturing device for management of gastrointestinal (GI) defects and stent anchorage. Endoscopic closure of GI defects including perforations, fistulas, and anastomotic leaks as well as stent anchorage has improved with technological advances. An endoscopic suturing device (OverStitch; Apollo Endosurgery Inc.) has been used. Retrospective study of consecutive patients who underwent endoscopic suturing for management of GI defects and/or stent anchorage were enrolled between March 2012 and January 2014 at multiple academic medical centers. Data regarding demographic information and outcomes including long-term success were collected. One hundred and twenty-two patients (mean age, 52.6 y; 64.2% females) underwent endoscopic suturing at 8 centers for stent anchorage (n=47; 38.5%), fistulas (n=40; 32.7%), leaks (n=15; 12.3%), and perforations (n=20; 16.4%). A total of 44.2% underwent prior therapy and 97.5% achieved technical success. Immediate clinical success was achieved in 79.5%. Long-term clinical success was noted in 78.8% with mean follow-up of 68 days. Clinical success was 91.4% in stent anchorage, 93% in perforations, 80% in fistulas, but only 27% in anastomotic leak closure. Endoscopic suturing for management of GI defects and stent anchoring is safe and efficacious. Stent migration after stent anchoring was reduced compared with published data. Long-term success without further intervention was achieved in the majority of patients. The role of endoscopic suturing for repair of anastomotic leaks remains unclear given limited success in this retrospective study.
Novel 3D-printing technique for caps to enable tailored therapeutic endoscopy.
Ko, Weon Jin; Song, Ga Won; Hong, Sung Pyo; Kwon, Chang-il; Hahm, Ki Baik; Cho, Joo Young
2016-03-01
To evaluate the feasibility of a tailored endoscopic cap created using 3D-printing technology that is customized according to esophagogastric lesions of each patient. Tailored endoscopic caps, which were designed and fabricated with a 3D printer, were inserted in 35 patients. The types of cap were side-hole cap made for cap-assisted endoscopic mucosal resection (EMRC), oblique-head cap designed for endoscopic submucosal dissection (ESD), wide-head cap used for Trucut biopsy (TCB), and narrow-tip cap to facilitate peroral endoscopic myotomy (POEM). EMRC in the esophagus and gastroesophageal junction was carried out using a side-hole cap in seven patients. Median total procedure time for successful removal of lesions was 14 min (range 8-50 min). Gastric ESD was carried out using with an oblique-head cap in 16 patients, for which the median total procedure time was 53 min. TCB in the esophagus was done using a wide-head cap in eight patients. While carrying out POEM for tunneling, a narrow-tip cap was used in four patients with achalasia. Based on the current proof-of-concept study, we anticipate that creating a tailored endoscopic cap is feasible for therapeutic endoscopy. © 2015 Japan Gastroenterological Endoscopy Society.
Proof-of-concept of a laser mounted endoscope for touch-less navigated procedures
Kral, Florian; Gueler, Oezguer; Perwoeg, Martina; Bardosi, Zoltan; Puschban, Elisabeth J; Riechelmann, Herbert; Freysinger, Wolfgang
2013-01-01
Background and Objectives During navigated procedures a tracked pointing device is used to define target structures in the patient to visualize its position in a registered radiologic data set. When working with endoscopes in minimal invasive procedures, the target region is often difficult to reach and changing instruments is disturbing in a challenging, crucial moment of the procedure. We developed a device for touch less navigation during navigated endoscopic procedures. Materials and Methods A laser beam is delivered to the tip of a tracked endoscope angled to its axis. Thereby the position of the laser spot in the video-endoscopic images changes according to the distance between the tip of the endoscope and the target structure. A mathematical function is defined by a calibration process and is used to calculate the distance between the tip of the endoscope and the target. The tracked tip of the endoscope and the calculated distance is used to visualize the laser spot in the registered radiologic data set. Results In comparison to the tracked instrument, the touch less target definition with the laser spot yielded in an over and above error of 0.12 mm. The overall application error in this experimental setup with a plastic head was 0.61 ± 0.97 mm (95% CI −1.3 to +2.5 mm). Conclusion Integrating a laser in an endoscope and then calculating the distance to a target structure by image processing of the video endoscopic images is accurate. This technology eliminates the need for tracked probes intraoperatively and therefore allows navigation to be integrated seamlessly in clinical routine. However, it is an additional chain link in the sequence of computer-assisted surgery thus influencing the application error. Lasers Surg. Med. 45:377–382, 2013. © 2013 Wiley Periodicals, Inc. PMID:23737122
Chino, A; Nagayama, S; Ishikawa, H; Morishige, K; Kishihara, T; Arai, M; Sugiura, Y; Motoi, N; Yamamoto, N; Tamegai, Y; Igarashi, M
2016-01-01
Since the serrated neoplastic pathway has been regarded as an important pathway of colorectal carcinogenesis, few reports have been published on clinical cases of cancer derived from sessile serrated adenoma/polyp, especially on recurrence after resected sessile serrated adenoma/polyp. An elderly woman underwent endoscopic mucosal resection of a flat elevated lesion, 30 mm in diameter, in the ascending colon; the histopathological diagnosis at that time was a hyperplastic polyp, now known as sessile serrated adenoma/polyp. Five years later, cancer due to the malignant transformation of the sessile serrated adenoma/polyp was detected at the same site. The endoscopic diagnosis was a deep invasive carcinoma with a remnant sessile serrated adenoma/polyp component. The carcinoma was surgically removed, and the pathological diagnosis was an adenocarcinoma with sessile serrated adenoma/polyp, which invaded the muscularis propria. The surgically removed lesion did not have a B-RAF mutation in either the sessile serrated adenoma/polyp or the carcinoma; moreover, the initial endoscopically resected lesion also did not have a B-RAF mutation. Immunohistochemistry confirmed negative MLH1 protein expression in only the cancer cells. Lynch syndrome was not detected on genomic examination. The lesion was considered to be a cancer derived from sessile serrated adenoma/polyp recurrence after endoscopic resection, because both the surgically and endoscopically resected lesions were detected at the same location and had similar pathological characteristics, with a serrated structure and low-grade atypia. Furthermore, both lesions had a rare diagnosis of a sessile serrated adenoma/polyp without B-RAF mutation. This report highlights the need for the follow-up colonoscopy after endoscopic resection and rethinking our resection procedures to improve treatment. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Riccioni, Maria Elena; Urgesi, Riccardo; Cianci, Rossella; Bizzotto, Alessandra; Galasso, Domenico; Costamagna, Guido
2012-01-01
Enteroscopy, defined as direct visualization of the small bowel with the use of a fiberoptic or capsule endoscopy, has progressed considerably over the past several years. The need for endoscopic access to improve diagnosis and treatment of small bowel disease has led to the development of novel technologies one of which is non-invasive, the video capsule, and a type of invasive technique, the device-assisted enteroscopy. In particular, the device-assisted enteroscopy consists then of three different types of instruments all able to allow, in skilled hands, to display partially or throughout its extension (if necessary) the small intestine. Newer devices, double balloon, single balloon and spiral endoscopy, are just entering clinical use. The aim of this article is to review recent advances in small bowel enteroscopy, focusing on indications, modifications to improve imaging and techniques, pitfalls, and clinical applications of the new instruments. With new technologies, the trials and tribulations of learning new endoscopic skills and determining their role in the diagnosis and treatment of small bowel disease come. Identification of small bowel lesions has dramatically improved. Studies are underway to determine the best strategy to apply new enteroscopy technologies for the diagnosis and management of small bowel disease, particularly obscure bleeding. Vascular malformations such as angiectasis and small bowel neoplasms as adenocarcinoma or gastrointestinal stromal tumors. Complete enteroscopy of the small bowel is now possible. However, because of the length of the small bowel, endoscopic examination and therapeutic maneuvers require significant skill, radiological assistance, the use of deep sedation with the assistance of the anesthetist. Prospective randomized studies are needed to guide diagnostic testing and therapy with these new endoscopic techniques. PMID:23189216
Integrated biophotonics in endoscopic oncology
NASA Astrophysics Data System (ADS)
Muguruma, Naoki; DaCosta, Ralph S.; Wilson, Brian C.; Marcon, Norman E.
2009-02-01
Gastrointestinal endoscopy has made great progress during last decade. Diagnostic accuracy can be enhanced by better training, improved dye-contrast techniques method, and the development of new image processing technologies. However, diagnosis using conventional endoscopy with white-light optical imaging is essentially limited by being based on morphological changes and/or visual attribution: hue, saturation and intensity, interpretation of which depends on the endoscopist's eye and brain. In microlesions in the gastrointestinal tract, we still rely ultimately on the histopathological diagnosis from biopsy specimens. Autofluorescence imaging system has been applied for lesions which have been difficult to morphologically recognize or are indistinct with conventional endoscope, and this approach has potential application for the diagnosis of dysplastic lesions and early cancers in the gastrointestinal tract, supplementing the information from white light endoscopy. This system has an advantage that it needs no administration of a photosensitive agent, making it suitable as a screening method for the early detection of neoplastic tissues. Narrow band imaging (NBI) is a novel endoscopic technique which can distinguish neoplastic and non-neoplastic lesions without chromoendoscopy. Magnifying endoscopy in combination with NBI has an obvious advantage, namely analysis of the epithelial pit pattern and the vascular network. This new technique allows a detailed visualization in early neoplastic lesions of esophagus, stomach and colon. However, problems remain; how to combine these technologies in an optimum diagnostic strategy, how to apply them into the algorithm for therapeutic decision-making, and how to standardize several classifications surrounding them. 'Molecular imaging' is a concept representing the most novel imaging methods in medicine, although the definition of the word is still controversial. In the field of gastrointestinal endoscopy, the future of endoscopic diagnosis is likely to be impacted by a combination of biomarkers and technology, and 'endoscopic molecular imaging' should be defined as "visualization of molecular characteristics with endoscopy". These innovations will allow us not only to locate a tumor or dysplastic lesion but also to visualize its molecular characteristics (e.g., DNA mutations and polymorphisms, gene and/or protein expression), and the activity of specific molecules and biological processes that affect tumor behavior and/or its response to therapy. In the near future, these methods should be promising technologies that will play a central role in gastrointestinal oncology.
Use of coblation in resection of juvenile nasopharyngeal angiofibroma.
Cannon, Daniel E; Poetker, David M; Loehrl, Todd A; Chun, Robert H
2013-06-01
We present a series of 4 patients with juvenile nasopharyngeal angiofibroma (JNA) who underwent Coblation-assisted endoscopic resection after preoperative embolization, and discuss the use and advantages of endoscopic Coblation-assisted resection of JNA. Our limited case series suggests that Coblation may be used in the resection of JNA after embolization in a relatively safe, efficient, and effective manner. Coblation allows for decreased bleeding, less need for instrumentation, and improved visualization. There are limited published data in the literature to date on the use of Coblation in endoscopic JNA resection. We describe its use in a more extensive tumor than those previously reported. Further studies are needed to fully define the safety and utility of Coblation technology for this application.
Bonatti, Johannes; Rehman, Atiq; Schwartz, Kimberly; Deshpande, Seema; Kon, Zachary; Lehr, Eric; Zimrin, David; Griffith, Bartley
2010-12-01
Robotic technology enables "port only" totally endoscopic coronary artery bypass grafting (TECAB). During early procedure development only single bypass grafts were feasible. Because current referral practice for coronary bypass surgery mostly includes multivessel disease, performance of multiple endoscopic bypass grafts is desirable. We report a case in which a patient received a right internal mammary artery bypass graft to the left anterior descending artery and a left internal mammary artery jump graft to 2 obtuse marginal branches. The procedure was performed through 5 ports on the arrested heart using the daVinci S robotic surgical system. This is the first reported triple bypass grafting procedure using an arrested heart approach.
Technical features of the robot-assisted trans-axillary thyroidectomy.
Axente, D D; Major, Z Z; Micu, C M; Constantea, N A
2013-01-01
Numerous minimally invasive techniques for thyroid surgery have been described in recent years. Technical disadvantages have led to low practicability, although these techniques proved to be safe and to deliver good results. The robotic system was developed to overcome the limits of endoscopic surgery.Recently, based on the advantages of this new technology, robot assisted endoscopic surgery was introduced for minimally invasive thyroid surgery as well. Our experience with robot-assisted transaxillary thyroid surgery begins in November 2010 when we have practiced our first unilateral total lobectomy. From November 2010 to March 2012, 50 patients underwent robot assisted endoscopic thyroid surgery using the transaxillary approach. The aim of this study is to present the technical details and particularities of this procedure, based on our experience.
Volonté, Francesco; Buchs, Nicolas C; Pugin, François; Spaltenstein, Joël; Schiltz, Boris; Jung, Minoa; Hagen, Monika; Ratib, Osman; Morel, Philippe
2013-09-01
Computerized management of medical information and 3D imaging has become the norm in everyday medical practice. Surgeons exploit these emerging technologies and bring information previously confined to the radiology rooms into the operating theatre. The paper reports the authors' experience with integrated stereoscopic 3D-rendered images in the da Vinci surgeon console. Volume-rendered images were obtained from a standard computed tomography dataset using the OsiriX DICOM workstation. A custom OsiriX plugin was created that permitted the 3D-rendered images to be displayed in the da Vinci surgeon console and to appear stereoscopic. These rendered images were displayed in the robotic console using the TilePro multi-input display. The upper part of the screen shows the real endoscopic surgical field and the bottom shows the stereoscopic 3D-rendered images. These are controlled by a 3D joystick installed on the console, and are updated in real time. Five patients underwent a robotic augmented reality-enhanced procedure. The surgeon was able to switch between the classical endoscopic view and a combined virtual view during the procedure. Subjectively, the addition of the rendered images was considered to be an undeniable help during the dissection phase. With the rapid evolution of robotics, computer-aided surgery is receiving increasing interest. This paper details the authors' experience with 3D-rendered images projected inside the surgical console. The use of this intra-operative mixed reality technology is considered very useful by the surgeon. It has been shown that the usefulness of this technique is a step toward computer-aided surgery that will progress very quickly over the next few years. Copyright © 2012 John Wiley & Sons, Ltd.
Evolution of Minimally Invasive Approaches to the Sella and Parasellar Region
Louis, Robert G.; Eisenberg, Amy; Barkhoudarian, Garni; Griffiths, Chester; Kelly, Daniel F.
2014-01-01
Introduction Given advancements in endoscopic image quality, instrumentation, surgical navigation, skull base closure techniques, and anatomical understanding, the endonasal endoscopic approach has rapidly evolved into a widely utilized technique for removal of sellar and parasellar tumors. Although pituitary adenomas and Rathke cleft cysts constitute the majority of lesions removed via this route, craniopharyngiomas, clival chordomas, parasellar meningiomas, and other lesions are increasingly removed using this approach. Paralleling the evolution of the endonasal route to the parasellar region, the supraorbital eyebrow craniotomy has also been increasingly used as an alternative minimally invasive approach to reach this skull base region. Similar to the endonasal route, the supraorbital route has been greatly facilitated by advances in endoscopy, along with development of more refined, low-profile instrumentation and surgical navigation technology. Objectives This review, encompassing both transcranial and transsphenoidal routes, will recount the high points and advances that have made minimally invasive approaches to the sellar region possible, the evolution of these approaches, and their relative indications and technical nuances. Data Synthesis The literature is reviewed regarding the evolution of surgical approaches to the sellar region beginning with the earliest attempts and emphasizing technological advances, which have allowed the evolution of the modern technique. The surgical techniques for both endoscopic transsphenoidal and supraorbital approaches are described in detail. The relative indications for each approach are highlighted using case illustrations. Conclusions Although tremendous advances have been made in transitioning toward minimally invasive transcranial and transsphenoidal approaches to the sella, further work remains to be done. Together, the endonasal endoscopic and the supraorbital endoscope-assisted approaches are complementary minimally invasive routes to the parasellar region. PMID:25992138
Peroral Endoscopic Myotomy for Treating Achalasia and Esophageal Motility Disorders
Youn, Young Hoon; Minami, Hitomi; Chiu, Philip Wai Yan; Park, Hyojin
2016-01-01
Peroral endoscopic myotomy (POEM) is the application of esophageal myotomy to the concept of natural orifice transluminal surgery (NOTES) by utilizing a submucosal tunneling method. Since the first case of POEM was performed for treating achalasia in Japan in 2008, this procedure is being more widely used by many skillful endosopists all over the world. Currently, POEM is a spotlighted, emerging treatment option for achalasia, and the indications for POEM are expanding to include long-standing, sigmoid shaped esophagus in achalasia, even previously failed endoscopic treatment or surgical myotomy, and other spastic esophageal motility disorders. Accumulating data about POEM demonstrate excellent short-term outcomes with minimal risk of major adverse events, and some existing long-term data show the efficacy of POEM to be long lasting. In this review article, we review the technical details and clinical outcomes of POEM, and discuss some considerations of POEM in special situations. PMID:26717928
Medical and Endoscopic Management of Gastric Varices
Al-Osaimi, Abdullah M. S.; Caldwell, Stephen H.
2011-01-01
In the past 20 years, our understanding of the pathophysiology and management options among patients with gastric varices (GV) has changed significantly. GV are the most common cause of upper gastrointestinal bleeding in patients with portal hypertension after esophageal varices (EV) and generally have more severe bleeding than EV. In the United States, the majority of GV patients have underlying portal hypertension rather than splenic vein thrombosis. The widely used classifications are the Sarin Endoscopic Classification and the Japanese Vascular Classifications. The former is based on the endoscopic appearance and location of the varices, while the Japanese classification is based on the underlying vascular anatomy. In this article, the authors address the current concepts of classification, epidemiology, pathophysiology, and emerging management options of gastric varices. They describe the stepwise approach to patients with gastric varices, including the different available modalities, and the pearls, pitfalls, and stop-gap measures useful in managing patients with gastric variceal bleed. PMID:22942544
Emerging indications of endoscopic radiofrequency ablation
Becq, Aymeric; Camus, Marine; Rahmi, Gabriel; de Parades, Vincent; Marteau, Philippe
2015-01-01
Introduction Radiofrequency ablation (RFA) is a well-validated treatment of dysplastic Barrett's esophagus. Other indications of endoscopic RFA are under evaluation. Results Four prospective studies (total 69 patients) have shown that RFA achieved complete remission of early esophageal squamous intra-epithelial neoplasia at a rate of 80%, but with a substantial risk of stricture. In the setting of gastric antral vascular ectasia, two prospective monocenter studies, and a retrospective multicenter study, (total 51 patients), suggest that RFA is efficacious in terms of reducing transfusion dependency. In the setting of chronic hemorrhagic radiation proctopathy, a prospective monocenter study and a retrospective multicenter study (total 56 patients) suggest that RFA is an efficient treatment. A retrospective comparative study (64 patients) suggests that RFA improves stents patency in malignant biliary strictures. Conclusions Endoscopic RFA is an upcoming treatment modality in early esophageal squamous intra-epithelial neoplasia, as well as in gastric, rectal, and biliary diseases. PMID:26279839
Broeders, Ivo A M J
2014-02-01
Robotic systems were introduced 15 years ago to support complex endoscopic procedures. The technology is increasingly used in gastro-intestinal surgery. In this article, literature on experimental- and clinical research is reviewed and ergonomic issues are discussed. literature review was based on Medline search using a large variety of search terms, including e.g. robot(ic), randomized, rectal, oesophageal, ergonomics. Review articles on relevant topics are discussed with preference. There is abundant evidence of supremacy in performing complex endoscopic surgery tasks when using the robot in an experimental setting. There is little high-level evidence so far on translation of these merits to clinical practice. Robotic systems may appear helpful in complex gastro-intestinal surgery. Moreover, dedicated computer based technology integrated in telepresence systems opens the way to integration of planning, diagnostics and therapy. The first high tech add-ons such as near infrared technology are under clinical evaluation. Copyright © 2014 Elsevier Ltd. All rights reserved.
Fundamentals of bipolar high-frequency surgery.
Reidenbach, H D
1993-04-01
In endoscopic surgery a very precise surgical dissection technique and an efficient hemostasis are of decisive importance. The bipolar technique may be regarded as a method which satisfies both requirements, especially regarding a high safety standard in application. In this context the biophysical and technical fundamentals of this method, which have been known in principle for a long time, are described with regard to the special demands of a newly developed field of modern surgery. After classification of this method into a general and a quasi-bipolar mode, various technological solutions of specific bipolar probes, in a strict and in a generalized sense, are characterized in terms of indication. Experimental results obtained with different bipolar instruments and probes are given. The application of modern microprocessor-controlled high-frequency surgery equipment and, wherever necessary, the integration of additional ancillary technology into the specialized bipolar instruments may result in most useful and efficient tools of a key technology in endoscopic surgery.
Deb, Sanchali; Tang, Shou-jiang; Abell, Thomas L.; McLawhorn, Tyler; Huang, Wen-Ding; Lahr, Christopher; To, S.D. Filip; Easter, Julie; Chiao, J.-C.
2016-01-01
Background Gastric stimulation via high-frequency, low-energy pulses can provide an effective treatment for gastric dysmotility; however, the current commercially available device requires surgical implantation for long-term stimulation and is powered by a nonrechargeable battery. Objective To test and describe endoscopic implantation techniques and testing of stimulation of a novel, wireless, batteryless, gastric electrical stimulation (GES) device. Design Endoscopic gastric implantation techniques were implemented, and in vivo gastric signals were recorded and measured in a non-survival swine model (n = 2; 50-kg animals). Intervention Five novel endoscopic gastric implantation techniques and stimulation of a novel, wireless, batteryless, GES device were tested on a non-survival swine model. Main Outcome Measurements Feasibility of 5 new endoscopic gastric implantation techniques of the novel, miniature, batteryless, wireless GES device while recording and measurement of in vivo gastric signals. Results All 5 of the novel endoscopic techniques permitted insertion and securing of the miniaturized gastrostimulator. By the help of these methods and miniaturization of the gastrostimulator, successful GES could be provided without any surgery. The metallic clip attachment was restricted to the mucosal surface, whereas the prototype tacks, prototype spring coils, percutaneous endoscopic gastrostomy wires/T-tag fasteners, and submucosal pocket endoscopic implantation methods attach the stimulator near transmurally or transmurally to the stomach. They allow more secure device attachment with optimal stimulation depth. Limitations Non-survival pig studies. Conclusion These 5 techniques have the potential to augment the utility of GES as a treatment alternative, to provide an important prototype for other dysmotility treatment paradigms, and to yield insights for new technological interfaces between non-invasiveness and surgery. PMID:22726478
Weight loss endoscopy: Development, applications, and current status
Kumar, Nitin
2016-01-01
Obesity and its comorbidities - including diabetes and obstructive sleep apnea - have taken a large and increasing toll on the United States and the rest of the world. The availability of commercial, clinical, and operative therapies for weight management have not been effective at a societal level. Endoscopic bariatric therapy is gaining acceptance as more effective than diet and lifestyle measures, and less invasive than bariatric surgery. Various endoscopic therapies are analogues of the restrictive or bypass components of bariatric surgery, utilizing gastric remodeling or intestinal anastomosis to achieve proven weight loss and metabolic benefits. Others, such as aspiration therapy, employ novel mechanisms of action. Intragastric balloons have recently been approved by the United States Food and Drug Administration, and a number of other technologies have completed large multicenter trials (such as AspireAssist aspiration therapy and Primary Obesity Surgery Endolumenal). Endoscopic sleeve gastroplasty and transoral outlet reduction for endoscopic revision of gastric bypass have proven safe and effective in a number of studies. As devices are approved for use, data will continue to accumulate for safety, effectiveness, and cost effectiveness. Bariatric endoscopists should be prepared to appropriately target and apply various endoscopic bariatric therapies in the context of a comprehensive long-term weight management program. PMID:27610017
[Natural orifice trans-luminal endoscopic surgery (notes)--a new era in general surgery].
Elazary, Ram; Horgan, Santiago; Talamini, Mark A; Rivkind, Avraham I; Mintz, Yoav
2008-10-01
Four years ago, a new surgical technique was presented, the natural orifice trans-luminal endoscopic surgery (NOTES). This technique provides an incisionless operation. The surgical devices are inserted into the peritoneal cavity through the gastrointestinal or the urogenital tracts. Today, a cholecystectomy can be performed using an advanced endoscope inserted through the stomach or the vagina. The advantages of NOTES are: reduced post operative pain, no hernias, no surgical wounds infections and better cosmetic results. The disadvantages are: difficulties in achieving safe enterotomy closure or a leak proof anastomosis, it necessitates performing more operations compared to open or laparoscopic operations in order to obtain the skills for performing these operations, and difficulties of acquiring satisfactory endoscopic vision due to lack of advanced technology. Several NOTES operations have already been performed in humans. However, many other surgical procedures were tested in laboratory animals. Development and improvement of surgical devices may promote this surgical modality in the future.
Kumamoto, Etsuko; Takahashi, Akihiro; Matsuoka, Yuichiro; Morita, Yoshinori; Kutsumi, Hiromu; Azuma, Takeshi; Kuroda, Kagayaki
2013-01-01
The MR-endoscope system can perform magnetic resonance (MR) imaging during endoscopy and show the images obtained by using endoscope and MR. The MR-endoscope system can acquire a high-spatial resolution MR image with an intraluminal radiofrequency (RF) coil, and the navigation system shows the scope's location and orientation inside the human body and indicates MR images with a scope view. In order to conveniently perform an endoscopy and MR procedure, the design of the user interface is very important because it provides useful information. In this study, we propose a navigation system using a wireless accelerometer-based controller with Bluetooth technology and a navigation technique to set the intraluminal RF coil using the navigation system. The feasibility of using this wireless controller in the MR shield room was validated via phantom examinations of the influence on MR procedures and navigation accuracy. In vitro examinations using an isolated porcine stomach demonstrated the effectiveness of the navigation technique using a wireless remote-control device.
Li, Yingchao; Mi, Chen; Li, Weizhi; She, Junjun
2016-11-01
Acute appendicitis is the most common abdominal emergency, but the diagnosis of appendicitis remains a challenge. Endoscopic retrograde appendicitis therapy (ERAT) is a new and minimally invasive procedure for the diagnosis and treatment of acute appendicitis. To investigate the diagnostic value of ERAT for acute appendicitis by the combination of colonoscopy and endoscopic retrograde appendicography (ERA). Twenty-one patients with the diagnosis of suspected uncomplicated acute appendicitis who underwent ERAT between November 2014 and January 2015 were included in this study. The main outcomes, imaging findings of acute appendicitis including colonoscopic direct-vision imaging and fluoroscopic ERA imaging, were retrospectively reviewed. Secondary outcomes included mean operative time, mean hospital stay, rate of complication, rate of appendectomy during follow-up period, and other clinical data. The diagnosis of acute appendicitis was established in 20 patients by positive ERA (5 patients) or colonoscopy (1 patient) alone or both (14 patients). The main colonoscopic imaging findings included mucosal inflammation (15/20, 75 %), appendicoliths (14/20, 70 %), and maturation (5/20, 25 %). The key points of ERA for diagnosing acute appendicitis included radiographic changes of appendix (17/20, 85 %), intraluminal appendicoliths (14/20, 70 %), and perforation (1/20, 5 %). Mean operative time of ERAT was 49.7 min, and mean hospital stay was 3.3 days. No patient converted to emergency appendectomy. Perforation occurred in one patient after appendicoliths removal was not severe and did not require invasive procedures. During at least 1-year follow-up period, only one patient underwent laparoscopic appendectomy. ERAT is a valuable procedure of choice providing a precise yield of diagnostic information for patients with suspected acute appendicitis by combination of colonoscopy and ERA.
Video: two novel endoscopic esophageal lengthening and reconstruction techniques.
Perretta, Silvana; Wall, James K; Dallemagne, Bernard; Harrison, Michael; Becmeur, François; Marescaux, Jacques
2011-10-01
Esophageal reconstruction presents a significant clinical challenge in patients ranging from neonates with long-gap esophageal atresia to adults after esophageal resection. Both gastric and colonic replacement conduits carry significant morbidity. As emerging organ-sparring techniques become established for early stage esophageal tumors, less morbid reconstruction techniques are warranted. We present two novel endoscopic approaches for esophageal lengthening and reconstruction in a porcine model. Two models of esophageal defects were created in pigs (30-35 kg) under general anesthesia and subsequently reconstructed with the novel techniques. The first model was a segmental defect of the esophagus created by thoracoscopically transecting the esophagus above the gastroesophageal (GE) junction. The first reconstruction technique involved bilateral submucosal endoscopic lengthening myotomies (BSELM) with a magnetic compression anastomosis (MAGNAMOSIS™). The second model was a wedge defect in the anterior esophagus created above the GE junction through a laparotomy. The second reconstruction technique involved an inverted mucosal-submucosal sleeve transposition graft (IMSTG) that crossed the esophageal gap and was secured in place with a self-expandable covered esophageal stent. Both techniques were feasible in the pig model. The BSELM approach lengthened the esophagus 1 cm for every 2 cm length of myotomy. The myotomy targeted only the inner circular fibers of the esophagus, with preservation of the longitudinal layer to protect against long-term dilation and pouching. The IMSTG approach generated a vascularized mucosal graft almost as long as the esophagus itself. Emerging endoscopic capabilities are enabling complex endoluminal esophageal procedures. BSELM and IMSTG are two novel and technically feasible approaches to esophageal lengthening and reconstruction. Further survival studies are needed to establish the safety and efficacy of these techniques.
Nakamura, Shotaro; Matsumoto, Takayuki; Sugimori, Hiroshi; Esaki, Motohiro; Kitazono, Takanari; Hashizume, Makoto
2014-05-01
To evaluate the prognostic factors, including risk scores (Glasgow-Blatchford score and AIMS65) in patients with acute upper or lower gastrointestinal bleeding. The medical records of patients who had undergone emergency gastrointestinal endoscopy for suspected gastrointestinal bleeding during the past 5 years were retrospectively analyzed. A total of 232 endoscopies (130 esophagogastroduodenoscopies, 102 colonoscopies) for 192 patients met the inclusion criteria. Median age was 66 years, and 64% of patients were males. Endoscopy identified causes for bleeding in 173 patients (post-endoscopic interventions for neoplastic lesions in 36 cases, colonic diverticula in 34, gastroduodenal ulcers in 29, gastric erosions in 15, vascular ectasia in 14, post-biopsy bleeding in 13, malignant tumors in 10, inflammatory conditions in nine, esophagogastric varices in five, Mallory-Weiss tears in four, nasalbleeding in three, and injury by swallowed blister pack in one), whereas the source of bleeding remained obscure in 19 patients. Blood transfusion was given in 97 patients (51%), and 97 (51%) underwent endoscopic hemostasis. During the follow-up period, 49 patients (26%) experienced rebleeding, seven of whom were treated by interventional radiology. Thirty-nine patients (20%) died as a result of various diseases. The probabilities of overall survival (OS) after 3 and 5 years were 71% and 67%, respectively. Cox multivariate analysis revealed blood transfusion, co-existing malignancy, absence of endoscopic hemostasis, and high AIMS65 score to be independent prognostic factors for poor OS. The AIMS65 score is useful for predicting the prognosis of patients with acute gastrointestinal bleeding. © 2013 The Authors. Digestive Endoscopy © 2013 Japan Gastroenterological Endoscopy Society.
Shimatani, Masaaki; Takaoka, Makoto; Tokuhara, Mitsuo; Miyoshi, Hideaki; Ikeura, Tsukasa; Okazaki, Kazuichi
2015-01-01
The endoscopic approach for biliary diseases in patients with surgically altered gastrointestinal anatomy (SAGA) had been generally deemed impractical. However, it was radically made feasible by the introduction of double balloon endoscopy (DBE) that was originally developed for diagnosis and treatments for small-bowel diseases. Followed by the subsequent development of single-balloon endoscopy (SBE) and spiral endoscopy (SE), interventions using several endoscopes for biliary disease in patients with SAGA widely gained an acceptance as a new modality. Many studies have been made on this new technique. Yet, some problems are to be solved. For instance, the mutual unavailability among devices due to different working lengths and channels, and unestablished standardization of procedural techniques can be raised. Additionally, in an attempt to standardize endoscopic procedures, it is important to evaluate biliary cannulating methods by case with existence of papilla or not. A full comprehension of the features of respective scope types is also required. However there are not many papers written as a review. In our manuscript, we would like to evaluate and make a review of the present status of diagnostic and therapeutic endoscopic retrograde cholangiopancreatography applying DBE, SBE and SE for biliary diseases in patients with SAGA for establishment of these modalities as a new technology and further improvement of the scopes and devices. PMID:26078830
Karstensen, John Gásdal; Klausen, Pia Helene; Saftoiu, Adrian; Vilmann, Peter
2014-06-28
While flexible endoscopy is essential for macroscopic evaluation, confocal laser endomicroscopy (CLE) has recently emerged as an endoscopic method enabling visualization at a cellular level. Two systems are currently available, one based on miniprobes that can be inserted via a conventional endoscope or via a needle guided by endoscopic ultrasound. The second system has a confocal microscope integrated into the distal part of an endoscope. By adding molecular probes like fluorescein conjugated antibodies or fluorescent peptides to this procedure (either topically or systemically administered during on-going endoscopy), a novel world of molecular evaluation opens up. The method of molecular CLE could potentially be used for estimating the expression of important receptors in carcinomas, subsequently resulting in immediate individualization of treatment regimens, but also for improving the diagnostic accuracy of endoscopic procedures by identifying otherwise invisible mucosal lesions. Furthermore, studies have shown that fluorescein labelled drugs can be used to estimate the affinity of the drug to a target organ, which probably can be correlated to the efficacy of the drug. However, several of the studies in this research field have been conducted in animal facilities or in vitro, while only a limited number of trials have actually been carried out in vivo. Therefore, safety issues still needs further evaluations. This review will present an overview of the implications and pitfalls, as well as future challenges of molecular CLE in gastrointestinal diseases.
Khan, Samiullah; Su, Shuai; Jiang, Kui; Wang, Bang-Mao
2018-01-01
Retrograde gastroesophageal intussusception (RGEI) is a relatively rare gastrointestinal (GI) disorder in which a portion of the stomach wall invaginates into the esophagus. More recently, peroral endoscopic myotomy (POEM) has emerged as an endoscopic alternative to surgical myotomy for achalasia, and, to the best of our knowledge, our case is the first RGEI after POEM to be reported. A 22-year-old male was presented with a history of vomiting, intractable retching and hematemesis for 3 days. He had a history of achalasia and underwent POEM 3 years ago caused by symptoms of severe dysphagia to solid and liquid. Initially, the patient was diagnosed with a blood-filled esophagus, and the mid esophagus was occluded with a ball-like mass, however, the final diagnosis of RGEI was made by thoracotomy. A therapeutic strategy of conservative treatment and left transthoracic surgery were applied. The surgery and post operative course were uneventful, and he remained asymptomatic 1 year after operation. POEM is a reliable and minimally invasive endoscopic method for esophageal achalasia. Early recognition and severity of RGEI are essential to decrease the unwanted complications. Upper GI series, esophagogastroduodenoscopy and computed tomography scan are helpful for diagnostic purposes of RGEI. Conservative treatment, endoscopic intervention, and surgery are the mainstay of treatments for RGEI. Copyright © 2017 The Authors. Published by Wolters Kluwer Health, Inc. All rights reserved.
Simple battery armor to protect against gastrointestinal injury from accidental ingestion
Laulicht, Bryan; Deshpande, Vikram; Langer, Robert; Karp, Jeffrey M.
2014-01-01
Inadvertent battery ingestion in children and the associated morbidity and mortality results in thousands of emergency room visits every year. Given the risk for serious electrochemical burns within hours of ingestion, the current standard of care for the treatment of batteries in the esophagus is emergent endoscopic removal. Safety standards now regulate locked battery compartments in toys, which have resulted in a modest reduction in inadvertent battery ingestion; specifically, 3,461 ingestions were reported in 2009, and 3,366 in 2013. Aside from legislation, minimal technological development has taken place at the level of the battery to limit injury. We have constructed a waterproof, pressure-sensitive coating, harnessing a commercially available quantum tunneling composite. Quantum tunneling composite coated (QTCC) batteries are nonconductive in the low-pressure gastrointestinal environment yet conduct within the higher pressure of standard battery housings. Importantly, this coating technology enables most battery-operated equipment to be powered without modification. If these new batteries are swallowed, they limit the external electrolytic currents responsible for tissue injury. We demonstrate in a large-animal model a significant decrease in tissue injury with QTCC batteries compared with uncoated control batteries. In summary, here we describe a facile approach to increasing the safety of batteries by minimizing the risk for electrochemical burn if the batteries are inadvertently ingested, without the need for modification of most battery-powered devices. PMID:25368176
Simple battery armor to protect against gastrointestinal injury from accidental ingestion.
Laulicht, Bryan; Traverso, Giovanni; Deshpande, Vikram; Langer, Robert; Karp, Jeffrey M
2014-11-18
Inadvertent battery ingestion in children and the associated morbidity and mortality results in thousands of emergency room visits every year. Given the risk for serious electrochemical burns within hours of ingestion, the current standard of care for the treatment of batteries in the esophagus is emergent endoscopic removal. Safety standards now regulate locked battery compartments in toys, which have resulted in a modest reduction in inadvertent battery ingestion; specifically, 3,461 ingestions were reported in 2009, and 3,366 in 2013. Aside from legislation, minimal technological development has taken place at the level of the battery to limit injury. We have constructed a waterproof, pressure-sensitive coating, harnessing a commercially available quantum tunneling composite. Quantum tunneling composite coated (QTCC) batteries are nonconductive in the low-pressure gastrointestinal environment yet conduct within the higher pressure of standard battery housings. Importantly, this coating technology enables most battery-operated equipment to be powered without modification. If these new batteries are swallowed, they limit the external electrolytic currents responsible for tissue injury. We demonstrate in a large-animal model a significant decrease in tissue injury with QTCC batteries compared with uncoated control batteries. In summary, here we describe a facile approach to increasing the safety of batteries by minimizing the risk for electrochemical burn if the batteries are inadvertently ingested, without the need for modification of most battery-powered devices.
A cost-utility analysis of ablative therapy for Barrett’s esophagus
Inadomi, John M.; Somsouk, Ma; Madanick, Ryan D.; Thomas, Jennifer P.; Shaheen, Nicholas J.
2009-01-01
Background & Aims Recommendations for patients with Barrett’s esophagus (BE) include endoscopic surveillance with esophagectomy for early-stage cancer, although new technologies to ablate dysplasia and metaplasia are available. This study compares the cost-utility of ablation with that of endoscopic surveillance strategies. Methods A decision analysis model was created to examine a population of patients with BE (mean age 50), with separate analyses for patients with no dysplasia, low-grade dysplasia (LGD), or high-grade dysplasia (HGD). Strategies compared were: no endoscopic surveillance; endoscopic surveillance with ablation for incident dysplasia; immediate ablation followed by endoscopic surveillance in all patients or limited to patients in whom metaplasia persisted, and esophagectomy. Ablation modalities modeled included radiofrequency, argon plasma coagulation, multipolar electrocoagulation and photodynamic therapy. Results Endoscopic ablation for patients with HGD could increase life expectancy by 3 quality-adjusted years at an incremental cost of < $6,000, compared with no intervention. Patients with LGD or no dysplasia can also be optimally managed with ablation, but continued surveillance after eradication of metaplasia is expensive. If ablation permanently eradicates at least 28% of LGD or 40% of non-dysplastic metaplasias, ablation would be preferred to surveillance. Conclusions Endoscopic ablation could be the preferred strategy for managing patients with BE with HGD. Ablation might also be preferred in subjects with LGD or no dysplasia, but the cost-effectiveness depends on the long-term effectiveness of ablation and whether surveillance endoscopy can be discontinued following successful ablation. As further post-ablation data become available, the optimal management strategy will be clarified. PMID:19272389
Zhang, Qiang; Wang, Fei; Wei, Gong; Cai, Jian-Qun; Zhi, Fa-Chao; Bai, Yang
2017-01-01
Endoscopic tunneling resection is a relatively novel endoscopic technology for removing gastric submucosal tumors. Our study aimed to compare the differences between tunneling and nontunneling resection for gastric submucosal tumors. Resections of gastric submucosal tumors (n = 97) performed from 2010 to 2015 at our endoscopy center were reviewed, and PubMed was searched for clinical studies on gastric submucosal tumor resection by endoscopic nontunneling and tunneling techniques. At our endoscopy center, nontunneling (Group 1) and tunneling resection (Group 2) were performed for 78 and 19 submucosal tumors, respectively; median tumor diameters were 15 and 20 mm (P = 0.086), median procedural times were 50 and 75 min (P = 0.017), successful resection rates were 94.9% (74/78) and 89.5% (17/19) (P = 0.334), and en bloc resection rates were 95.9% (71/74) and 94.1% (16/17) (P = 0.569) in the Groups 1 and 2, respectively. Postoperative fever, delayed hemorrhage and perforation, hospitalization time, and hospitalization expense were statistically similar between the 2 groups. A literature review on gastric submucosal tumor resection suggested that the en bloc resection rates of the two methods for tumors with a median diameter of 15-30 mm were also high, and there were no relapses during the follow-up period. Both endoscopic nontunneling and tunneling resection seem to be effective and safe methods for removing relatively small gastric submucosal tumors. Compared with endoscopic nontunneling, tunneling resection does not seem to have distinct advantages for gastric submucosal tumors, and has a longer mean operative time.
Coagulation syndrome: Delayed perforation after colorectal endoscopic treatments
Hirasawa, Kingo; Sato, Chiko; Makazu, Makomo; Kaneko, Hiroaki; Kobayashi, Ryosuke; Kokawa, Atsushi; Maeda, Shin
2015-01-01
Various procedure-related adverse events related to colonoscopic treatment have been reported. Previous studies on the complications of colonoscopic treatment have focused primarily on perforation or bleeding. Coagulation syndrome (CS), which is synonymous with transmural burn syndrome following endoscopic treatment, is another typical adverse event. CS is the result of electrocoagulation injury to the bowel wall that induces a transmural burn and localized peritonitis resulting in serosal inflammation. CS occurs after polypectomy, endoscopic mucosal resection (EMR), and even endoscopic submucosal dissection (ESD). The occurrence of CS after polypectomy or EMR varies according previous reports; most report an occurrence rate around 1%. However, artificial ulcers after ESD are largely theoretical, and CS following ESD was reported in about 9% of cases, which is higher than that for CS after polypectomy or EMR. Most cases of post-polypectomy syndrome (PPS) have an excellent prognosis, and they are managed conservatively with medical therapy. PPS rarely develops into delayed perforation. Delayed perforation is a severe adverse event that often requires emergency surgery. Since few studies have reported on CS and delayed perforation associated with CS, we focused on CS after colonoscopic treatments in this review. Clinicians should consider delayed perforation in CS patients. PMID:26380051
General considerations and updates in pediatric gastrointestinal diagnostic endoscopy
2010-01-01
Gastrointestinal and colonic endoscopic examinations have been performed in pediatric patients in Korea for 3 decades. Endoscopic procedures are complex and may be unsafe if special concerns are not considered. Many things have to be kept in mind before, during, and after the procedure. Gastrointestinal endoscopy is one of the most frequently performed procedure in children nowadays, Since the dimension size of the endoscopy was modified for pediatric patients 15 years ago, endoscopic procedures are almost performed routinely in pediatric gastrointestinal patients. The smaller size of the scope let the physicians approach the diagnostic and therapeutic endoscopic procedures. But this is an invasive procedure, so the procedure itself may provoke an emergence state. The procedure-related complications can more easily occur in pediatric patients. Sedation-related or procedure-related respiratory, cardiovascular complications are mostly important and critical in the care. The endoscopists are required to consider diverse aspects of the procedure - patient preparation, indications and contraindications, infection controls, sedation methods, sedative medicines and the side effects of each medicine, monitoring during and after the procedure, and complications related with the procedure and medicines - to perform the procedure successfully and safely. This article presents some important guidelines and recommendations for gastrointestinal endoscopy through literature review. PMID:21189965
New endoscopic and cytologic tools for cancer surveillance in the digestive tract
Brentnall, Teresa A.; Dominitz, Jason A.
2009-01-01
Synopsis Cancer surveillance is an increasing part of everyday practice in gastrointestinal endoscopy due to the identification of high risk groups from genetic and biomarker testing, genealogic and epidemiologic studies, and the increasing number of cancer survivors. An efficient surveillance program requires a cost-effective means for image-guided cancer detection and biopsy. A laser-based tethered-capsule endoscope with enhanced spectral imaging is introduced for unsedated surveillance of the lower esophagus. An ultrathin version of this same endoscope technology provides a 1.2-mm guidewire with imaging capability and cannula-style tools are proposed for image-guided biopsy. Advanced 3D cell visualization techniques are described for increasing the sensitivity of early cancer diagnosis from hematoxylin-stained cells sampled from the pancreatic and biliary ducts. PMID:19423026
Cappabianca, Paolo; Cavallo, Luigi Maria; de Divitiis, Oreste; Solari, Domenico; Esposito, Felice; Colao, Annamaria
2008-01-01
Pituitary surgery is a continuous evolving speciality of the neurosurgeons' armamentarium, which requires precise anatomical knowledge, technical skills and integrated appreciation of the pituitary pathophysiology. What we consider "pure" endoscopic transsphenoidal surgery is a procedure performed through the nose and the sphenoid bone, with the endoscope alone throughout the whole approach to visualize the surgical target area and without the use of any transsphenoidal retractor. It offers some advantages due to the endoscope itself: a superior close-up view of the relevant anatomy and an enlarged working angle are provided with an increased panoramic vision inside the surgical area. Concerning results in terms of mass removal, relief of clinical symptoms, cure of the underlying disease and complication rate, they are, at least, similar to those reported in the major microsurgical series, but patient compliance is by far better. Furthermore transsphenoidal endoscopy brings advantages to the patient (less nasal traumatism, no nasal packing, less post-op pain and usually quick recovery), to the surgeon (wider and closer view of the surgical target area, increase of the scientific activity as from the peer-reviewed literature on the topic in the last 10 years, smoothing of interdisciplinary cooperation), to the institution (shorter post-op hospital stay, increase of the case load). Besides, further progress and technological advance are expected from the close cooperation between different technologies and industries. Continuing works in such field of "minimalism" will offer further possibilities to provide the surgeon with even more effectiveness and safety, and, on the other hand, the patient with improvement of results.
Large bowel obstruction due to gallstones: an endoscopic problem?
Waterland, Peter; Khan, Faisal Shehzaad; Durkin, Damien
2014-01-01
A 73-year-old man was admitted with symptoms of large bowel obstruction. An emergency CT scan revealed pneumobilia and large bowel obstruction at the level of the rectosigmoid due to a 4×4 cm impacted gallstone. Flexible sigmoidoscopy confirmed the diagnosis but initial attempts to drag the stone into the rectum failed. An endoscopic mechanical lithotripter was employed to repeatedly fracture the gallstone into smaller fragments, which were passed spontaneously the next day. The patient made a complete recovery avoiding the potential dangers of surgery. This case report discusses cholecystoenteric fistula and a novel minimally invasive treatment for large bowel obstruction due to gallstones. PMID:24390966
Large bowel obstruction due to gallstones: an endoscopic problem?
Waterland, Peter; Khan, Faisal Shehzaad; Durkin, Damien
2014-01-03
A 73-year-old man was admitted with symptoms of large bowel obstruction. An emergency CT scan revealed pneumobilia and large bowel obstruction at the level of the rectosigmoid due to a 4×4 cm impacted gallstone. Flexible sigmoidoscopy confirmed the diagnosis but initial attempts to drag the stone into the rectum failed. An endoscopic mechanical lithotripter was employed to repeatedly fracture the gallstone into smaller fragments, which were passed spontaneously the next day. The patient made a complete recovery avoiding the potential dangers of surgery. This case report discusses cholecystoenteric fistula and a novel minimally invasive treatment for large bowel obstruction due to gallstones.
Surgical management of peptic ulcer disease today--indication, technique and outcome.
Zittel, T T; Jehle, E C; Becker, H D
2000-03-01
The current surgical management of peptic ulcer disease and its outcome have been reviewed. Today, surgery for peptic ulcer disease is largely restricted to the treatment of complications. In peptic ulcer perforation, a conservative treatment trial can be given in selected cases. If laparotomy is necessary, simple closure is sufficient in the large majority of cases, and definitive ulcer surgery to reduce gastric acid secretion is no longer justified in these patients. Laparoscopic surgery for perforated peptic ulcer has failed to prove to be a significant advantage over open surgery. In bleeding peptic ulcers, definitive hemostasis can be achieved by endoscopic treatment in more than 90% of cases. In 1-2% of cases, immediate emergency surgery is necessary. Some ulcers have a high risk of re-bleeding, and early elective surgery might be advisable. Surgical bleeding control can be achieved by direct suture and extraluminal ligation of the gastroduodenal artery or by gastric resection. Benign gastric outlet obstruction can be controlled by endoscopic balloon dilatation in 70% of cases, but gastrojejunostomy or gastric resection are necessary in about 30% of cases. Elective surgery for peptic ulcer disease has been largely abandoned, and bleeding or obstructing ulcers can be managed safely by endoscopic treatment in most cases. However, surgeons will continue to encounter patients with peptic ulcer disease for emergency surgery. Currently, laparoscopic surgery has no proven advantage in peptic ulcer surgery.
Gersak, Mariana M; Badea, Radu; Graur, Florin; Hajja, Nadim Al; Furcea, Luminita; Dudea, Sorin M
2015-06-01
Endoscopic ultrasound is the most accurate type of examination for the assessment of rectal tumors. Over the years, the method has advanced from gray-scale examination to intravenous contrast media administration and to different types of elastography. The multimodal approach of tumors (transrectal, transvaginal) is adapted to each case. 3D ultrasound is useful for spatial representation and precise measurement of tumor formations, using CT/MR image reconstruction; color elastography is useful for tumor characterization and staging; endoscopic ultrasound using intravenous contrast agents can help study the amount of contrast agent targeted at the level of the tumor formations and contrast wash-in/wash-out time, based on the curves displayed on the device. The transvaginal approach often allows better visualization of the tumor than the transrectal approach. Performing the procedure with the rectal ampulla distended with contrast agent may be seen as an optimization of the examination methodology. All these aspects are additional methods for gray-scale endoscopic ultrasound, capable of increasing diagnostic accuracy. This paper aims at reviewing the progress of transrectal and transvaginal ultrasound, generically called endoscopic ultrasound, for rectal tumor diagnosis and staging, with emphasis on the current state of the method and its development trends.
MEMS scanning micromirror for optical coherence tomography.
Strathman, Matthew; Liu, Yunbo; Keeler, Ethan G; Song, Mingli; Baran, Utku; Xi, Jiefeng; Sun, Ming-Ting; Wang, Ruikang; Li, Xingde; Lin, Lih Y
2015-01-01
This paper describes an endoscopic-inspired imaging system employing a micro-electromechanical system (MEMS) micromirror scanner to achieve beam scanning for optical coherence tomography (OCT) imaging. Miniaturization of a scanning mirror using MEMS technology can allow a fully functional imaging probe to be contained in a package sufficiently small for utilization in a working channel of a standard gastroesophageal endoscope. This work employs advanced image processing techniques to enhance the images acquired using the MEMS scanner to correct non-idealities in mirror performance. The experimental results demonstrate the effectiveness of the proposed technique.
MEMS scanning micromirror for optical coherence tomography
Strathman, Matthew; Liu, Yunbo; Keeler, Ethan G.; Song, Mingli; Baran, Utku; Xi, Jiefeng; Sun, Ming-Ting; Wang, Ruikang; Li, Xingde; Lin, Lih Y.
2014-01-01
This paper describes an endoscopic-inspired imaging system employing a micro-electromechanical system (MEMS) micromirror scanner to achieve beam scanning for optical coherence tomography (OCT) imaging. Miniaturization of a scanning mirror using MEMS technology can allow a fully functional imaging probe to be contained in a package sufficiently small for utilization in a working channel of a standard gastroesophageal endoscope. This work employs advanced image processing techniques to enhance the images acquired using the MEMS scanner to correct non-idealities in mirror performance. The experimental results demonstrate the effectiveness of the proposed technique. PMID:25657887
Doppler imaging using spectrally-encoded endoscopy
Yelin, Dvir; Bouma, B. E.; Rosowsky, J. J.; Tearney, G. J.
2009-01-01
The capability to image tissue motion such as blood flow through an endoscope could have many applications in medicine. Spectrally encoded endoscopy (SEE) is a recently introduced technique that utilizes a single optical fiber and miniature diffractive optics to obtain endoscopic images through small diameter probes. Using spectral-domain interferometry, SEE is furthermore capable of three-dimensional volume imaging at video rates. Here we show that by measuring relative spectral phases, this technology can additionally measure Doppler shifts. Doppler SEE is demonstrated in flowing Intralipid phantoms and vibrating middle ear ossicles. PMID:18795020
Diana, M; Leroy, J; Wall, J; De Ruijter, V; Lindner, V; Dhumane, P; Mutter, D; Marescaux, J
2012-06-01
Endoluminal full-thickness closure of the rectal wall is critical in emerging procedures including endoscopic submucosal dissection and transrectal natural orifice transluminal endoscopic surgery (NOTES). This study aimed to compare manual suture using the transanal endoscopic operation platform (TEO; Karl Storz, Tüttlingen, Germany) with the end-to-end anastomosis hemorrhoid circular stapler (EEA; Covidien, Dublin, Ireland) for closure of the rectal viscerotomy during transrectal NOTES segmental colectomy. A total of 12 swine underwent transrectal hybrid NOTES partial colectomies. Animals were divided into two groups according to the viscerotomy closure technique: 1) TEO manual suture; 2) EEA circular stapler closure. Mean (± SD) viscerotomy closure time was 67.5 ± 59.5 minutes and 31.5 ± 19.6 minutes for TEO and EEA, respectively. There was one conversion to laparoscopy in the TEO group and a misfiring in the EEA group that required a TEO salvage suture. There was one positive air-leak test in each group. Peritoneal fluid collected at the end of the procedure tested positive for bacterial contamination in all cases. A mild stenosis was present in 4 /6 viscerotomies (67 %) in the TEO group and in 1/6 (17 %) in the EEA group on endoscopic control. Inflammatory changes were mild in 3/5 (60 %) and 4/5 (80 %) viscerotomies in the TEO and EEA groups, respectively, whereas severe inflammation was found in 2/5 (TEO) and 1 /5 (EEA). Transrectal viscerotomy closure using the EEA circular stapler technique is feasible, easy to perform, and histologically comparable to suture closure through a TEO platform. It may offer an attractive alternative for NOTES segmental colectomies and endoscopic resections. © Georg Thieme Verlag KG Stuttgart · New York.
Lubbe, D; Semple, P
2008-06-01
To demonstrate the importance of pre-operative ear, nose and throat assessment in patients undergoing endoscopic, transsphenoidal surgery for pituitary tumours. Literature pertaining to the pre-operative otorhinolaryngological assessment and management of patients undergoing endoscopic anterior skull base surgery is sparse. We describe two cases from our series of 59 patients undergoing endoscopic pituitary surgery. The first case involved a young male patient with a large pituitary macroadenoma. His main complaint was visual impairment. He had no previous history of sinonasal pathology and did not complain of any nasal symptoms during the pre-operative neurosurgical assessment. At the time of surgery, a purulent nasal discharge was seen emanating from both middle meati. Surgery was abandoned due to the risk of post-operative meningitis, and postponed until the patient's chronic rhinosinusitis was optimally managed. The second patient was a 47-year-old woman with a large pituitary macroadenoma, who presented to the neurosurgical department with a main complaint of diplopia. She too gave no history of previous nasal problems, and she underwent uneventful surgery using the endoscopic, transnasal approach. Two weeks after surgery, she presented to the emergency unit with severe epistaxis. A previous diagnosis of hereditary haemorrhagic telangiectasia was discovered, and further surgical and medical intervention was required before the epistaxis was finally controlled. Pre-operative otorhinolaryngological assessment is essential prior to endoscopic pituitary or anterior skull base surgery. A thorough otorhinolaryngological history will determine whether any co-morbid diseases exist which could affect the surgical field. Nasal anatomy can be assessed via nasal endoscopy and sinusitis excluded. Computed tomography imaging is a valuable aid to decisions regarding additional procedures needed to optimise access to the pituitary fossa.
In Vivo Cancer Biomarkers of Esophageal Neoplasia
Lu, Shaoying; Wang, Thomas D
2011-01-01
Summary The emergence of in vivo cancer biomarkers is promising tool for early detection, risk stratification, and therapeutic intervention in the esophagus, where adenocarcinoma is increasing at a rate that is faster than any other in industrialized nations. Exciting advances in target identification, probe development, and optical instrumentation are creating tremendous new opportunities for advancing techniques of molecular imaging. Progress in these areas is being made with small animal models of esophageal cancer using surgical approaches to induce reflux of acid and bile, and these findings are beginning to be evaluated in the clinic. Further identification of relevant targets, characterization of specific probes, and development of endoscopic imaging technologies are needed to further this direction in the field of molecular medicine. In the future, new methods that use in vivo cancer biomarkers for the early detection of neoplastic changes in the setting of Barrett's esophagus will become available. PMID:19126962
Van Rompaey, Jason; Bowers, Greg; Radhakrishnan, Jay; Panizza, Benedict; Solares, C Arturo
2014-06-01
Injury to the internal carotid artery is a feared complication of endoscopic endonasal surgery of the skull base. Such an event, although rare, is associated with high morbidity and mortality. Even if bleeding is controlled, permanent neurological defects frequently persist. Many techniques have been developed to manage internal carotid artery rupture with varying degrees of success. The purpose of this study was to explore endoscopic management of arterial damage with endovascular closure devices used for a femoral arteriotomy. The ability to remotely suture a damaged artery permits the possible adaptation of this technology in managing endoscopic arterial complications. Technical note. After the creation of an endoscopic endonasal corridor in a cadaveric specimen, an arteriotomy was created at the cavernous portion of the internal carotid artery. The Angio-Seal, StarClose, and MynxGrip vascular closure devices were utilized under endoscopic guidance to repair the arteriotomy. Angiography was then done on a cadaver sutured with the StarClose. Both the Angio-Seal and StarClose were deployed quickly and appeared to provide sufficient closure of the arteriotomy. The Angio-Seal required the use of a guidewire and was longer to deploy when compared with the StarClose. The StarClose deployment was quick and facile. The MynxGrip also deployed without difficulty. The Angio-Seal and StarClose systems were both successfully deployed utilizing an endoscopic endonasal approach. The MynxGrip was the easiest to deploy and has the greatest potential to be of benefit in this application. Further studies with hemodynamic models are required to properly assess the appropriateness in this setting. NA. © 2014 The American Laryngological, Rhinological and Otological Society, Inc.
Hong, Christopher S; Prevedello, Daniel M; Elder, J Bradley
2016-03-01
Tubular brain retractors may improve access to deep-seated brain lesions while potentially reducing the risks of collateral neurological injury associated with standard microsurgical approaches. Here, microscope-assisted resection of lesions using tubular retractors is assessed to determine if it is superior to endoscope-assisted surgery due to the technological advancements associated with modern tubular ports and surgical microscopes. Following institutional approval of the tubular port, data obtained from the initial 20 patients to undergo transportal resection of deep-seated brain lesions were analyzed in this study. The pathological entities of the resected tissues included metastatic tumors (8 patients), glioma (7), meningioma (1), neurocytoma (1), radiation necrosis (1), primitive neuroectodermal tumor (1), and hemangioblastoma (1). Surgery incorporated endoscopic (5 patients) or microscopic (15) assistance. The locations included the basal ganglia (11 patients), cerebellum (4), frontal lobe (2), temporal lobe (2), and parietal lobe (1). Cases were reviewed for neurological outcomes, extent of resection (EOR), and complications. Technical data for the port, surgical microscope, and endoscope were analyzed. EOR was considered total in 14 (70%), near total (> 95%) in 4 (20%), and subtotal (< 90%) in 2 (10%) of 20 patients. Incomplete resection was associated with the basal ganglia location (p < 0.05) and use of the endoscope (p < 0.002). Four of 5 (80%) endoscope-assisted cases were near-total (2) or subtotal (2) resection. Histopathological diagnosis, presenting neurological symptoms, and demographics were not associated with EOR. Complication rates were low and similar between groups. Initial experience with tubular retractors favors use of the microscope rather than the endoscope due to a wider and 3D field of view. Improved microscope optics and tubular retractor design allows for binocular vision with improved lighting for the resection of deep-seated brain lesions.
Zhang, Qiang; Wang, Fei; Wei, Gong; Cai, Jian-Qun; Zhi, Fa-Chao; Bai, Yang
2017-01-01
Background/Aim: Endoscopic tunneling resection is a relatively novel endoscopic technology for removing gastric submucosal tumors. Our study aimed to compare the differences between tunneling and nontunneling resection for gastric submucosal tumors. Materials and Methods: Resections of gastric submucosal tumors (n = 97) performed from 2010 to 2015 at our endoscopy center were reviewed, and PubMed was searched for clinical studies on gastric submucosal tumor resection by endoscopic nontunneling and tunneling techniques. Results: At our endoscopy center, nontunneling (Group 1) and tunneling resection (Group 2) were performed for 78 and 19 submucosal tumors, respectively; median tumor diameters were 15 and 20 mm (P = 0.086), median procedural times were 50 and 75 min (P = 0.017), successful resection rates were 94.9% (74/78) and 89.5% (17/19) (P = 0.334), and en bloc resection rates were 95.9% (71/74) and 94.1% (16/17) (P = 0.569) in the Groups 1 and 2, respectively. Postoperative fever, delayed hemorrhage and perforation, hospitalization time, and hospitalization expense were statistically similar between the 2 groups. A literature review on gastric submucosal tumor resection suggested that the en bloc resection rates of the two methods for tumors with a median diameter of 15–30 mm were also high, and there were no relapses during the follow-up period. Conclusions: Both endoscopic nontunneling and tunneling resection seem to be effective and safe methods for removing relatively small gastric submucosal tumors. Compared with endoscopic nontunneling, tunneling resection does not seem to have distinct advantages for gastric submucosal tumors, and has a longer mean operative time. PMID:28139501
NASA Astrophysics Data System (ADS)
Alemohammad, Milad; Yuan, Wu; Mavadia-Shukla, Jessica; Liang, Wenxuan; Yu, Xiaoyun; Yu, Shaoyong; Li, Xingde
2016-03-01
Endoscopic OCT is a promising technology enabling noninvasive in vivo imaging of internal organs, such as the gastrointestinal tract and airways. The past few years have witnessed continued efforts to achieve ultrahigh resolution and speed. It is well-known that the axial resolution in OCT imaging has a quadratic dependence on the central wavelength. While conventional OCT endoscopes operate in 1300 nm wavelength, the second-generation endoscopes are designed for operation around 800 nm where turn-key, broadband sources are becoming readily available. Traditionally 1300 nm OCT endoscopes are scanned at the proximal end, and a broadband fiber-optic rotary joint as a key component in scanning endoscopic OCT is commercially available. Bandwidths in commercial 800 nm rotary joints are unfortunately compromised due to severe chromatic aberration, which limits the resolution afforded by the broadband light source. In the past we remedied this limitation by using a home-made capillary-tube-based rotary joint where the maximum reliable speed is ~10 revolutions/second. In this submission we report our second-generation, home-built high-speed and broadband rotary joint for 800 nm wavelength, which uses achromatic doublets in order achieve broadband achromatic operation. The measured one-way throughput of the rotary joint is >67 % while the fluctuation of the double-pass coupling efficiency during 360° rotation is less than +/-5 % at a speed of 70 revolutions/second. We demonstrate the operation of this rotary joint in conjunction with our ultrahigh-resolution (2.4 µm in air) diffractive catheter by three-dimensional full-circumferential endoscopic imaging of guinea pig esophagus at 70 frames per second in vivo.
NASA Astrophysics Data System (ADS)
Xu, Yingshun; Singh, Janak; Siang, Teo Hui; Ramakrishna, Kotlanka; Premchandran, C. S.; Sheng, Chen Wei; Kuan, Chuah Tong; Chen, Nanguang; Olivo, Malini C.; Sheppard, Colin J. R.
2007-07-01
In this paper, we present a non-rotatory circumferential scanning optical probe integrated with a MEMS scanner for in vivo endoscopic optical coherence tomography (OCT). OCT is an emerging optical imaging technique that allows high resolution cross-sectional imaging of tissue microstructure. To extend its usage to endoscopic applications, a miniaturized optical probe based on Microelectromechanical Systems (MEMS) fabrication techniques is currently desired. A 3D electrothermally actuated micromirror realized using micromachining single crystal silicon (SCS) process highlights its very large angular deflection, about 45 degree, with low driving voltage for safety consideration. The micromirror is integrated with a GRIN lens into a waterproof package which is compatible with requirements for minimally invasive endoscopic procedures. To implement circumferential scanning substantially for diagnosis on certain pathological conditions, such as Barret's esophagus, the micromirror is mounted on 90 degree to optical axis of GRIN lens. 4 Bimorph actuators that are connected to the mirror on one end via supporting beams and springs are selected in this micromirror design. When actuators of the micromirror are driven by 4 channels of sinusoidal waveforms with 90 degree phase differences, beam focused by a GRIN is redirected out of the endoscope by 45 degree tilting mirror plate and achieve circumferential scanning pattern. This novel driving method making full use of very large angular deflection capability of our micromirror is totally different from previously developed or developing micromotor-like rotatory MEMS device for circumferential scanning.
A journey into the technical evolution of neuroendoscopy.
Di Ieva, Antonio; Tam, Mallorie; Tschabitscher, Manfred; Cusimano, Michael D
2014-12-01
Neuroendoscopy has become a well-accepted technique in neurosurgery. After the introduction of the endoscope in medical practice by Phillip Bozzini in 1806, influential individuals such as Harold Hopkins and Karl Storz paved the way for its current success. With the present pace of technologic advancements, great improvement in the instrumentation is expected along with the status of neuroendoscopy in the neurosurgical field. Specific attention is given to the history of the development of the endoscope, while also discussing more recent advances dating from 1990 onward. The importance of each development for the purpose of the instrument is explained. Gaps in the literature regarding the technical aspects of neuroendoscopy, including the optical physics in the endoscope, three-dimensional endoscopy, and clinical applications of neuroendoscopy and robotics, are addressed. Copyright © 2014 Elsevier Inc. All rights reserved.
Endoscopic spectral-domain polarization-sensitive optical coherence tomography system
NASA Astrophysics Data System (ADS)
Wang, Yi; Chen, Xiaodong; Hu, Zhiqiang; Li, Qiao; Yu, Daoyin
2008-02-01
In this paper, we introduced a fiber-based endoscopic Spectral-domain Polarization-sensitive OCT (SD-PS-OCT) experimental scheme for detecting the internal organ disease, which is based on low-coherence interferometer and two spectrometers. The SD-PS-OCT has the advantages of both Spectral-domain OCT (SD-OCT) and Polarization-sensitive OCT (PS-OCT). It is able to get the real-time image of reflectivity and birefringence distribution of tissue at the same time. The usage of SD-PS-OCT in endoscopic diagnosing system provides it the possibility to detect the internal organ disease. Since SD-PS-OCT can image the pathological changes of biological tissue below surface (1-3mm) with high resolution (1-15μm), it is able to help diagnosing early diseases of internal organs, which makes it a biomedical technology with bright future.
Hysteroscopic simulator for training and educational purposes.
Lim, Fabian; Brown, Ian; McColl, Ryan; Seligman, Cory; Alsaraira, Amer
2006-01-01
Hysteroscopy is an extensively popular option in evaluating and treating women with infertility. The procedure utilizes an endoscope, inserted through the vagina and cervix to examine the intra-uterine cavity via a monitor. The difficulty of hysteroscopy from the surgeon's perspective is the visual spatial perception of interpreting 3D images on a 2D monitor, and the associated psychomotor skills in overcoming the fulcrum-effect. Despite the widespread use of this procedure, current qualified hysteroscopy surgeons have not been trained the fundamentals through an organized curriculum. The emergence of virtual reality as an educational tool for this procedure, and for other endoscopic procedures, has undoubtedly raised interests. The ultimate objective is for the inclusion of virtual reality training as a mandatory component for gynecological endoscopic training. Part of this process involves the design of a simulator, encompassing the technical difficulties and complications associated with the procedure. The proposed research examines fundamental hysteroscopic factors as well as current training and accreditation norms, and proposes a hysteroscopic simulator design that is suitable for educating and training.
Imaging pancreatobiliary ductal system with optical coherence tomography: A review
Mahmud, Mohammad S; May, Gray R; Kamal, Mohammad M; Khwaja, Ahmed S; Sun, Carry; Vitkin, Alex; Yang, Victor XD
2013-01-01
An accurate, noninvasive and cost-effective method of in situ tissue evaluation during endoscopy would be highly advantageous for the detection of dysplasia or early cancer and for identifying different disease stages. Optical coherence tomography (OCT) is a noninvasive, high-resolution (1-10 μm) emerging optical imaging method with potential for identifying microscopic subsurface features in the pancreatic and biliary ductal system. Tissue microstructure of pancreaticobiliary ductal system has been successfully imaged by inserting an OCT probe through a standard endoscope operative channel. High-resolution OCT images and the technique’s endoscopic compatibility have allowed for the microstructural diagnostic of the pancreatobiliary diseases. In this review, we discussed currently available pancreaticobiliary ductal imaging systems to assess the pancreatobiliary tissue microstructure and to evaluate varieties of pancreaticobiliary disorders and diseases. Results show that OCT can improve the quality of images of pancreatobiliary system during endoscopic retrograde cholangiopancheatography procedure, which may be important in distinguishing between the neoplastic and non-neoplastic lesions. PMID:24255746
di Pietro, Massimiliano; Canto, Marcia I; Fitzgerald, Rebecca C
2018-01-01
Because the esophagus is easily accessible with endoscopy, early diagnosis and curative treatment of esophageal cancer is possible. However, diagnosis is often delayed because symptoms are not specific during early stages of tumor development. The onset of dysphagia is associated with advanced disease, which has a survival at 5 years lower than 15%. Population screening by endoscopy is not cost-effective, but a number of alternative imaging and cell analysis technologies are under investigation. The ideal screening test should be inexpensive, well tolerated, and applicable to primary care. Over the past 10 years, significant progress has been made in endoscopic diagnosis and treatment of dysplasia (squamous and Barrett's), and early esophageal cancer using resection and ablation technologies supported by evidence from randomized controlled trials. We review the state-of-the-art technologies for early diagnosis and minimally invasive treatment, which together could reduce the burden of disease. Copyright © 2018 AGA Institute. Published by Elsevier Inc. All rights reserved.
Maida, Marcello; Camilleri, Salvatore; Manganaro, Michele; Garufi, Serena; Scarpulla, Giuseppe
2017-10-15
Colorectal cancer (CRC) is the third most common cancer in males and second in females, and globally the fourth cause for cancer death worldwide. Oncological screening of CRC has a major role in the management of the disease and it is mostly performed by colonoscopy. Anyway, effectiveness of endoscopic screening for CRC strictly depends on adequate detection and removal of potentially precancerous lesions, and accuracy of colonoscopy in detection of adenomas is still suboptimal. For this reason, several technological advances have been implemented in order to improve the diagnostic sensitivity of colonoscopy in adenoma detection. Among these: (1) Visual technologies such as chromoendoscopy and narrow band imaging; (2) optical innovation as high definition endoscopy, full-spectrum endoscopy or Third Eye Retroscope; and (3) mechanical advances as Cap assisted colonoscopy, Endocuff, Endoring and G-Eye endoscope. All these technologies advances have been tested over time by clinical studies with mixed results. Which of them is more likely to be successful in the next future?
Yeh, Jennifer M; Hur, Chin; Ward, Zachary; Schrag, Deborah; Goldie, Sue J
2016-04-01
To estimate the cost-effectiveness of noncardia gastric adenocarcinoma (NCGA) screening strategies based on new biomarker and endoscopic technologies. Using an intestinal-type NCGA microsimulation model, we evaluated the following one-time screening strategies for US men: (1) serum pepsinogen to detect gastric atrophy (with endoscopic follow-up of positive screen results), (2) endoscopic screening to detect dysplasia and asymptomatic cancer (with endoscopic mucosal resection (EMR) treatment for detected lesions) and (3) Helicobacter pylori screening and treatment. Screening performance, treatment effectiveness, cancer and cost data were based on published literature and databases. Subgroups included current, former and never smokers. Outcomes included lifetime cancer risk and incremental cost-effectiveness ratios (ICERs), expressed as cost per quality-adjusted-life-year (QALY) gained. Screening the general population at age 50 years reduced the lifetime intestinal-type NCGA risk (0.24%) by 26.4% with serum pepsinogen screening, 21.2% with endoscopy and EMR and 0.2% with H. pylori screening/treatment. Targeting current smokers reduced the lifetime risk (0.35%) by 30.8%, 25.5%, and 0.1%, respectively. For all subgroups, serum pepsinogen screening was more effective and more cost-effective than all other strategies, although its ICER varied from $76,000/QALY (current smokers) to $105,400/QALY (general population). Results were sensitive to H. pylori prevalence, screen age and serum pepsinogen test sensitivity. Probabilistic sensitivity analysis found that at a $100,000/QALY willingness-to-pay threshold, the probability that serum pepsinogen screening was preferred was 0.97 for current smokers. Although not warranted for the general population, targeting high-risk smokers for serum pepsinogen screening may be a cost-effective strategy to reduce intestinal-type NCGA mortality. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Role of laser photoablative therapy and expandable metal stents in colorectal carcinoma
NASA Astrophysics Data System (ADS)
Chennupati, Raja S.; Trowers, Eugene A.
2000-05-01
Metallic stents are effective in relieving colorectal obstruction in more than 80% of cases. Self expanding metallic stents allow for decompression of the proximal colon and preoperative bowel cleansing. Hence, emergent surgery for large bowel obstruction with its associated high morbidity and mortality might be avoided. Endoscopic laser photoablation and stent placement may successfully palliate inoperable colorectal cancer patients by maintaining luminal patency and avoiding the need for a colostomy. Major complications associated with metallic stents include pressure necrosis, perforation, bleeding and migration. The effectiveness of expandable metallic stents in obstructive colorectal carcinoma is critically reviewed. The authors present a concise review of the effectiveness of endoscopic laser photoablation and expandable metal stent placement.
Preclinical cadaveric study of transanal endoscopic da Vinci® surgery.
Hompes, R; Rauh, S M; Hagen, M E; Mortensen, N J
2012-08-01
Single-port platforms are increasingly being used for transanal surgery and may be associated with a shorter learning curve than transanal endoscopic microsurgery. However, these procedures remain technically challenging, and robotic technology could overcome some of the limitations and increase intraluminal manoeuvrability. An initial experimental experience with transanal endoscopic da Vinci(®) surgery (TEdS) using a glove port on human cadavers is reported. After initial dry laboratory experiments, the feasibility of TEdS and ideal set-up were further evaluated in human cadavers. For transanal access a glove port was constructed on-table by using a circular anal dilator, a standard wound retractor and a surgical glove. A da Vinci(®) Si HD system was used in combination with the glove port for transanal endoscopic resections. It was possible to perform all necessary tasks to complete a full-thickness excision and closure of the rectal wall, with cadavers in both prone and supine positions. The stable magnified view, combined with the EndoWrist(®) technology of the robotic instruments, made every task straightforward. Intraluminal manoeuvrability could be improved further by intersecting the robotic instruments. The glove port proved to be very reliable and the inherent flexibility of the glove facilitated docking of the robotic arms in a narrow confined space. Using a reliable and universally available glove port, TEdS was feasible and a preferred set-up was determined. Further clinical trials will be necessary to assess the safety and efficacy of this technique. Copyright © 2012 British Journal of Surgery Society Ltd. Published by John Wiley & Sons, Ltd.
A Real-Time Localization System for an Endoscopic Capsule Using Magnetic Sensors †
Pham, Duc Minh; Aziz, Syed Mahfuzul
2014-01-01
Magnetic sensing technology offers an attractive alternative for in vivo tracking with much better performance than RF and ultrasound technologies. In this paper, an efficient in vivo magnetic tracking system is presented. The proposed system is intended to localize an endoscopic capsule which delivers biomarkers around specific locations of the gastrointestinal (GI) tract. For efficiently localizing a magnetic marker inside the capsule, a mathematical model has been developed for the magnetic field around a cylindrical magnet and used with a localization algorithm that provides minimum error and fast computation. The proposed tracking system has much reduced complexity compared to the ones reported in the literature to date. Laboratory tests and in vivo animal trials have demonstrated the suitability of the proposed system for tracking a magnetic marker with expected accuracy. PMID:25379813
Tian, W; Xi, H Q; Wang, B
2017-08-01
The continuous development and application of new technology in thyroid surgery has promoted the rapid improvement of thyroid surgery. New technology in the field of thyroid surgery has developed rapidly. The application of neural monitoring technology has enabled the thyroid surgery to enter an accurate era. Imtraoperative neuromonitoring and continuous intraoperative neuromonitoring have made the recurrent laryngeal nerve protection more secure. Nano-carbon parathyroid gland negative imaging technology could identify parathyroid gland more precise. However, when the nano-carbon was used, the injection time, position and dosage should be grasped so as to achieve the best effect of negative imaging. Endoscopic and robotic thyroid surgery could meet the demand of cosmetic. "Treatment first, beauty second" is still the principle to be strictly followed. Do not blindly expand indications and pursue endoscopic surgery. Energy surgical instruments' update made the operation more efficient, while the instruments have some disadvantages. Thyroid surgeon must correctly understand the working principle of new energy devices and use them rationally. Through grasping the working principle and application skills of new technology in clinical work, definiting its advantages and disadvantages, adhereing to the "reasonable choice, standard application" principle, learning the pioneers' experience, the application of new thyroid diagnosis and treatment technology could be more reasonable and safe.
Itoh, Akihiro; Kawashima, Hiroki; Ohno, Eizaburo; Itoh, Yuya; Nakamura, Yosuke; Hiramatsu, Takeshi; Sugimoto, Hiroyuki; Sumi, Hajime; Hayashi, Daijiro; Ohmiya, Naoki; Miyahara, Ryoji; Nakamura, Masanao; Funasaka, Kohei; Ishigami, Masatoshi; Katano, Yoshiaki; Goto, Hidemi
2013-01-01
Background/Aims To confirm the feasibility of using newly developed endoscopic ultrasound (EUS) with Zone sonography™ technology (ZST; Fujifilm Corp.). Methods Seventy-five patients with pancreatic disorders were enrolled: 45 with intraductal papillary mucinous neoplasm; 15 with ductal carcinoma; five with neuroendocrine tumors; three with serous cystic neoplasms; and seven with simple cysts. The endoscopes used were EG-530UR2 and EG-530UT2 (Fujifilm Corp.). Two items were evaluated: visualization depth among four frequencies and image quality after automatic adjustment of sound speed (AASS), assessed using a 5-scale Likert scale by two endosonographers blinded to disease status. Because sound speed could be manually controlled, besides AASS, image quality at sound speeds of 1,440 and 1,600 m/sec were also assessed. Results In all cases, sufficient images were obtained in the range of 3 cm from the EUS probe. Judgments of image quality before AASS were 3.49±0.50, 3.65±0.48, respectively. After AASS, A and B scored 4.36±0.48 and 4.40±0.49 (p<0.0001). There were significant differences in the data before and after AASS and plus 60 m/sec, but no significant difference between the datasets were seen after AASS and at sound speeds manually set for minus 100 m/sec. Conclusions EUS with ZST was shown to be feasible in this preliminary experiment. Further evaluation of this novel technology is necessary and awaited. PMID:23898392
Hirooka, Yoshiki; Itoh, Akihiro; Kawashima, Hiroki; Ohno, Eizaburo; Itoh, Yuya; Nakamura, Yosuke; Hiramatsu, Takeshi; Sugimoto, Hiroyuki; Sumi, Hajime; Hayashi, Daijiro; Ohmiya, Naoki; Miyahara, Ryoji; Nakamura, Masanao; Funasaka, Kohei; Ishigami, Masatoshi; Katano, Yoshiaki; Goto, Hidemi
2013-07-01
To confirm the feasibility of using newly developed endoscopic ultrasound (EUS) with Zone sonography™ technology (ZST; Fujifilm Corp.). Seventy-five patients with pancreatic disorders were enrolled: 45 with intraductal papillary mucinous neoplasm; 15 with ductal carcinoma; five with neuroendocrine tumors; three with serous cystic neoplasms; and seven with simple cysts. The endoscopes used were EG-530UR2 and EG-530UT2 (Fujifilm Corp.). Two items were evaluated: visualization depth among four frequencies and image quality after automatic adjustment of sound speed (AASS), assessed using a 5-scale Likert scale by two endosonographers blinded to disease status. Because sound speed could be manually controlled, besides AASS, image quality at sound speeds of 1,440 and 1,600 m/sec were also assessed. In all cases, sufficient images were obtained in the range of 3 cm from the EUS probe. Judgments of image quality before AASS were 3.49±0.50, 3.65±0.48, respectively. After AASS, A and B scored 4.36±0.48 and 4.40±0.49 (p<0.0001). There were significant differences in the data before and after AASS and plus 60 m/sec, but no significant difference between the datasets were seen after AASS and at sound speeds manually set for minus 100 m/sec. EUS with ZST was shown to be feasible in this preliminary experiment. Further evaluation of this novel technology is necessary and awaited.
Antoniou, Dimitris; Christopoulos-Geroulanos, George
2011-01-01
Although foreign body ingestion is a common problem in children, there are no clear guidelines regarding the management of ingested foreign bodies. The aim of this study was to evaluate the effectiveness of our protocol in the work-up and management of children with ingested foreign bodies. Between September 2002 and August 2010, a total of 675 children with suspected foreign body ingestion were seen in the emergency department. At initial presentation, the majority of foreign bodies were located in the stomach (n=392, 58.1%) followed by the small intestine (n=221, 32.7%) and esophagus (n=62, 9.2%). Based on our protocol, 84 (12.4%) patients were admitted at initial presentation, and 5 after a 48-hour observation period at home; 61 (9%) required prompt endoscopic removal. Sixty-eight (10.1%) patients returned for endoscopic removal after a four-week observation period, and 3 (0.4%) patients underwent delayed surgery due to complications. The overall success rate of endoscopic retrieval was 96.1%. There were no major complications. The majority of ingested foreign bodies will pass spontaneously and most children can be safely observed at home. Selective endoscopic intervention is the preferable method for the removal of ingested foreign bodies in pediatric patients.
Kerr, Edward E; Jamshidi, Ali; Carrau, Ricardo L; Campbell, Raewyn G; Filho, Leo F Ditzel; Otto, Bradley A; Prevedello, Daniel M
2017-10-01
Objectives The pedicled nasoseptal flap (NSF) has dramatically reduced postoperative cerebrospinal fluid leakage following endoscopic endonasal approach (EEA) surgery. Although rare, its arterial supply may be damaged during harvest or may be preoperatively damaged for numerous reasons. Early recognition permits harvesting a contralateral flap before sacrificing its pedicle as part of the surgical exposure or use of an alternative flap. Design Technical feasibility study and case series. Setting Tertiary care university-associated medical center. Participants Five patients requiring an EEA with NSF reconstruction. Main Outcome Measures During NSF harvest, intravenous indocyanine green (IVICG) was administered, and a customized endoscopic system was used to visualize the emerging fluorescence. At the end of each case, just before final positioning of the NSF, additional IVICG was administered, and the custom endoscope was again introduced to evaluate fluorescence. Results In four patients, the entire NSF fluoresced brightly with IVICG on initial harvest and before final positioning. One patient showed heterogeneous fluorescence of the pedicle and distal parts of the NSF at both stages. All NSFs healed well without complication. Conclusion IVICG facilitates real-time evaluation NSF's arterial supply. This may provide early recognition of arterial compromise, allowing the harvest of alternate flaps or modification of surgery.
Hsu, Ping-I; Lo, Gin-Ho; Lo, Ching-Chu; Lin, Chiun-Ku; Chan, Hoi-Hung; Wu, Chung-Jen; Shie, Chang-Bih; Tsai, Pei-Min; Wu, Deng-Chyang; Wang, Wen-Ming; Lai, Kwok-Hung
2004-01-01
AIM: The role of intravenous pantoprazole in treatment of patients with high-risk bleeding peptic ulcers following endoscopic hemostasis remains uncertain. We therefore conducted the pilot prospective randomized study to assess whether intravenous pantoprazole could improve the efficacy of H2-antagonist as an adjunct treatment following endoscopic injection therapy for bleeding ulcers. METHODS: Patients with active bleeding ulcers or ulcers with major signs of recent bleeding were treated with distilled water injection. After hemostasis was achieved, they were randomly assigned to receive intravenous pantoprazole or ranitidine. RESULTS: One hundred and two patients were enrolled in this prospective trial. Bleeding recurred in 2 patients (4%) in the pantoprazole group (n = 52), as compared with 8 (16%) in the ranitidine group (n = 50). The rebleeding rate was significantly lower in the pantoprazole group (P = 0.04). There were no statistically significant differences between the groups with regard to the need for emergency surgery (0% vs 2%), transfusion requirements (4.9 ± 5.9 vs 5.7 ± 6.8 units), hospital days (5.9 ± 3.2 vs 7.5 ± 5.0 d) or mortality (2% vs 2%). CONCLUSION: Pantoprozole is superior to ranitidine as an adjunct treatment to endoscopic injection therapy in high-risk bleeding ulcers. PMID:15534928
Reality named endoscopic ultrasound biliary drainage
Guedes, Hugo Gonçalo; Lopes, Roberto Iglesias; de Oliveira, Joel Fernandez; Artifon, Everson Luiz de Almeida
2015-01-01
Endoscopic ultrasound (EUS) is used for diagnosis and evaluation of many diseases of the gastrointestinal (GI) tract. In the past, it was used to guide a cholangiography, but nowadays it emerges as a powerful therapeutic tool in biliary drainage. The aims of this review are: outline the rationale for endoscopic ultrasound-guided biliary drainage (EGBD); detail the procedural technique; evaluate the clinical outcomes and limitations of the method; and provide recommendations for the practicing clinician. In cases of failed endoscopic retrograde cholangiopancreatography (ERCP), patients are usually referred for either percutaneous transhepatic biliary drainage (PTBD) or surgical bypass. Both these procedures have high rates of undesirable complications. EGBD is an attractive alternative to PTBD or surgery when ERCP fails. EGBD can be performed at two locations: transhepatic or extrahepatic, and the stent can be inserted in an antegrade or retrograde fashion. The drainage route can be transluminal, duodenal or transpapillary, which, again, can be antegrade or retrograde [rendezvous (EUS-RV)]. Complications of all techniques combined include pneumoperitoneum, bleeding, bile leak/peritonitis and cholangitis. We recommend EGBD when bile duct access is not possible because of failed cannulation, altered upper GI tract anatomy, gastric outlet obstruction, a distorted ampulla or a periampullary diverticulum, as a minimally invasive alternative to surgery or radiology. PMID:26504507
Muscarella, Lawrence F
2014-01-01
To evaluate the risk of transmission of carbapenem-resistant Enterobacteriaceae (CRE) and their related superbugs during gastrointestinal (GI) endoscopy. Reports of outbreaks linked to GI endoscopes contaminated with different types of infectious agents, including CRE and their related superbugs, were reviewed. Published during the past 30 years, both prior to and since CRE’s emergence, these reports were obtained by searching the peer-reviewed medical literature (via the United States National Library of Medicine’s “MEDLINE” database); the Food and Drug Administration’s Manufacturer and User Facility Device Experience database, or “MAUDE”; and the Internet (via Google’s search engine). This review focused on an outbreak of CRE in 2013 following the GI endoscopic procedure known as endoscopic retrograde cholangiopancreatography, or ERCP, performed at “Hospital X” located in the suburbs of Chicago (IL; United States). Part of the largest outbreak of CRE in United States history, the infection and colonization of 10 and 28 of this hospital’s patients, respectively, received considerable media attention and was also investigated by the Centers for Disease Control and Prevention (CDC), which published a report about this outbreak in Morbidity and Mortality Weekly Report (MMWR), in 2014. This report, along with the results of an independent inspection of Hospital X’s infection control practices following this CRE outbreak, were also reviewed. While this article focuses primarily on the prevention of transmissions of CRE and their related superbugs in the GI endoscopic setting, some of its discussion and recommendations may also apply to other healthcare settings, to other types of flexible endoscopes, and to other types of transmissible infectious agents. This review found that GI endoscopy is an important risk factor for the transmission of CRE and their related superbugs, having been recently associated with patient morbidity and mortality following ERCP. The CDC reported in MMWR that the type of GI endoscope, known as an ERCP endoscope, that Hospital X used to perform ERCP in 2013 on the 38 patients who became infected or colonized with CRE might be particularly challenging to clean and disinfect, because of the complexity of its physical design. If performed in strict accordance with the endoscope manufacturer’s labeling, supplemented as needed with professional organizations’ published guidelines, however, current practices for reprocessing GI endoscopes, which include high-level disinfection, are reportedly adequate for the prevention of transmission of CRE and their related superbugs. Several recommendations are provided to prevent CRE transmissions in the healthcare setting. CRE transmissions are not limited to contaminated GI endoscopes and also have been linked to other reusable flexible endoscopic instrumentation, including bronchoscopes and cystoscopes. In conclusion, contaminated GI endoscopes, particularly those used during ERCP, have been causally linked to outbreaks of CRE and their related superbugs, with associated patient morbidity and mortality. Thorough reprocessing of these complex reusable instruments is necessary to prevent disease transmission and ensure patient safety during GI endoscopy. Enhanced training and monitoring of reprocessing staffers to verify the proper cleaning and brushing of GI endoscopes, especially the area around, behind and near the forceps elevator located at the distal end of the ERCP endoscope, are recommended. If the ERCP endoscope features a narrow and exposed channel that houses a wire connecting the GI endoscope’s control head to this forceps elevator, then this channel’s complete reprocessing, including its flushing with a detergent using a procedure validated for effectiveness, is also emphasized. PMID:25324917
Acoustics of the trained versus untrained singing voice.
Howard, David M
2009-06-01
Acoustic voice analysis is now widely available on today's multimedia computers and knowledge of the acoustics of the trained and untrained singing voice has advanced dramatically in recent years. New techniques have emerged that are providing clearer representations of aspects of the physiology of voice function and a greater understanding of the differences between the voices of untrained and trained singers. Improvements in endoscope technology are changing understanding of vocal fold function and videokymography provides a new way of interpreting the output; some new and interesting possibilities are emerging. Larynx height variation is a feature of untrained singing and singing in different styles and its measurement has been inaccurate hitherto; perhaps the laryngoaltimeter will provide a solution. Magnetic resonance imaging is now a vital tool for vocal tract shape measurement but a new bio-inspired computing is offering a possible alternative. Differences between an untrained and trained singing voice lie in one or more of breathing technique, larynx settings or vocal tract settings. Measurement techniques in each of these areas are important to provide data on the singing voice, and accurate data are essential for natural personalized electronic voice synthesis in the future.
Gastric cancer: Prevention, screening and early diagnosis
Pasechnikov, Victor; Chukov, Sergej; Fedorov, Evgeny; Kikuste, Ilze; Leja, Marcis
2014-01-01
Gastric cancer continues to be an important healthcare problem from a global perspective. Most of the cases in the Western world are diagnosed at late stages when the treatment is largely ineffective. Helicobacter pylori (H. pylori) infection is a well-established carcinogen for gastric cancer. While lifestyle factors are important, the efficacy of interventions in their modification, as in the use of antioxidant supplements, is unconvincing. No organized screening programs can be found outside Asia (Japan and South Korea). Although several screening approaches have been proposed, including indirect atrophy detection by measuring pepsinogen in the circulation, none of them have so far been implemented, and more study data is required to justify any implementation. Mass eradication of H. pylori in high-risk areas tends to be cost-effective, but its adverse effects and resistance remain a concern. Searches for new screening biomarkers, including microRNA and cancer-autoantibody panels, as well as detection of volatile organic compounds in the breath, are in progress. Endoscopy with a proper biopsy follow-up remains the standard for early detection of cancer and related premalignant lesions. At the same time, new advanced high-resolution endoscopic technologies are showing promising results with respect to diagnosing mucosal lesions visually and targeting each biopsy. New histological risk stratifications (classifications), including OLGA and OLGIM, have recently been developed. This review addresses the current means for gastric cancer primary and secondary prevention, the available and emerging methods for screening, and new developments in endoscopic detection of early lesions of the stomach. PMID:25320521
Laparoscopic and endoscopic cooperative surgery for gastrointestinal tumor
Ishibashi, Rei; Mitsui, Takashi; Aikou, Susumu; Kodashima, Shinya; Yamashita, Hiroharu; Yamamichi, Nobutake; Hirata, Yoshihiro; Fujishiro, Mitsuhiro; Seto, Yasuyuki; Koike, Kazuhiko
2017-01-01
With technological progress of endoscopic submucosal dissection (ESD) in the last decade, several laparoscopic and endoscopic cooperative surgeries (LECS) for gastrointestinal tumor have recently been developed. LECS is definitely favorable to the minimization of surgical margin, which leads to functional and anatomical preservation of gastrointestinal tract. LECS for gastrointestinal tumor is mainly sorted by two categories: exposure procedures and non-exposure procedures between endoluminal and extraluminal spaces. Exposure procedures have the potential risk of gastric contents or tumor cells spilling out over the abdominal cavity, because the stomach wall has to be perforated intentionally during the procedure. In order to avoid the potential these risks, non-exposure procedures have been developed. Currently, the LECS concept has rapidly permeated for treatment of gastrointestinal tumor due to its certainty and safety, although there is still room for improvement to lessen its technical difficulty. This review describes the current LECS for gastrointestinal tumor based on the several articles. PMID:28616402
NASA Astrophysics Data System (ADS)
Tate, Tyler H.; McGregor, Davis; Barton, Jennifer K.
2017-02-01
The optical design for a dual modality endoscope based on piezo scanning fiber technology is presented including a novel technique to combine forward-viewing navigation and side viewing OCT. Potential applications include navigating body lumens such as the fallopian tube, biliary ducts and cardiovascular system. A custom cover plate provides a rotationally symmetric double reflection of the OCT beam to deviate and focus the OCT beam out the side of the endoscope for cross-sectional imaging of the tubal lumen. Considerations in the choice of the scanning fiber are explored and a new technique to increase the divergence angle of the scanning fiber to improve system performance is presented. Resolution and the necessary scanning density requirements to achieve Nyquist sampling of the full image are considered. The novel optical design lays the groundwork for a new approach integrating side-viewing OCT into multimodality endoscopes for small lumen imaging. KEYWORDS:
Natural-orifice translumenal endoscopic surgery (NOTES): minimally invasive evolution or revolution?
Mohan, Helen M; O'Riordan, James M; Winter, Desmond C
2013-06-01
Since the first animal experimental laparoscopy in 1902, minimal access techniques have revolutionized surgery. Using the natural orifice dates back to at least the second century when Soranus performed a vaginal hysterectomy. The main difference between traditional endolumenal surgery and the translumenal approach of natural-orifice translumenal endoscopic surgery (NOTES) is the intentional puncture of a healthy organ in NOTES to access a cavity or other organ. The aim of this review was to examine the past, present, and potential future role of NOTES in the context of other developments in minimal access surgery. NOTES is at an early stage in its development and a convincing benefit over laparoscopy has not been demonstrated. Concerns regarding complications, for example of viscerotomy closure, have limited the widespread uptake of pure NOTES. However, it is likely that technological advances for NOTES surgery will enhance conventional laparoscopic and endoscopic techniques.
Proposal of a Budget-Friendly Camera Holder for Endoscopic Ear Surgery.
Ozturan, Orhan; Yenigun, Alper; Aksoy, Fadlullah; Ertas, Burak
2018-01-01
Endoscopic ear surgery (EES) is increasingly a preferred technique in otologic society. It offers excellent visualization of the anatomical structures directly and behind the corners with variable angled telescopes. It also provides reduced operative morbidity due to being able to perform surgical interventions with less invasive approaches. Operative preparation and setup time and cost of endoscopy system are less expensive compared with surgical microscopes. On the other hand, the main disadvantage of EES is that the surgery has to be performed with 1 single hand. It is certainly restrictive for an ear surgeon who has been operating with 2 hands under otologic microscopic views for years and certainly requires a learning period and perseverance. Holding the endoscope by a second surgeon is not executable because of insufficient surgical space.Endoscope/camera holders have been developed for those who need the comfort and convenience afforded by double-handed microscopic ear surgery. An ideal endoscope holder should be easy-to-set up, easily controlled, providing a variety of angled views, allowing the surgeon to operate with 2 hands and, budget-friendly. In this article, a commercially available 11-inch magic arm camera holder is proposed by the authors to be used in EES due to its versatile, convenient, and budget-friendly features. It allows 2-handed EES through existing technology and is affordable for surgeons looking for a low-cost and practical solution.
Schurr, M O; Wehrmann, M; Kunert, W; Melzer, A; Lirici, M M; Trapp, R; Kanehira, E; Buess, G
1994-01-01
Precise cutting combined with reliable coagulation of the margins of the lesion is an important requirement for dissection techniques in endoscopic surgery. These requirements are met by the two most common ancillary energy sources applied for endoscopic dissection today, electrosurgery and "thermal lasers", mostly the Nd:YAG. For the comparison of the histological effects of monopolar and bipolar high frequency with the Nd:YAG laser an experimental in vitro and in vivo study has been performed. In order to evaluate the advantages of non thermal dissection for endoscopic procedures, a water jet cutting system was included in the in vitro study. In parenchymatous tissue the water jet was found to be the least traumatic technique, followed by bipolar high frequency, laser and monopolar high frequency. The water jet was not applicable for intestinal dissection since uncontrolled bloating of the rectal wall with uncontrolled disruption of the tissue layers occurred. A general disadvantage is that secure haemostasis in the line of incision is hard to achieve. In the microscopic comparison of the shape of the incision, the Nd:YAG laser produced the smoothest lesions with well-defined margins. The monopolar technique was more often associated with irregular and sometimes fissured margins. These results were confirmed in the in vivo part of the study (Transanal Endoscopic Microsurgery).
García-Garrigós, Elena; Arenas-Jiménez, Juan José; Monjas-Cánovas, Irene; Abarca-Olivas, Javier; Cortés-Vela, Jesús Julián; De La Hoz-Rosa, Javier; Guirau-Rubio, Maria Dolores
2015-01-01
In the last 2 decades, endoscopic endonasal transsphenoidal surgery has become the most popular choice of neurosurgeons and otolaryngologists to treat lesions of the skull base, with minimal invasiveness, lower incidence of complications, and lower morbidity and mortality rates compared with traditional approaches. The transsphenoidal route is the surgical approach of choice for most sellar tumors because of the relationship of the sphenoid bone to the nasal cavity below and the pituitary gland above. More recently, extended approaches have expanded the indications for transsphenoidal surgery by using different corridors leading to specific target areas, from the crista galli to the spinomedullary junction. Computer-assisted surgery is an evolving technology that allows real-time anatomic navigation during endoscopic surgery by linking preoperative triplanar radiologic images and intraoperative endoscopic views, thus helping the surgeon avoid damage to vital structures. Preoperative computed tomography is the preferred modality to show bone landmarks and vascular structures. Radiologists play an important role in surgical planning by reporting extension of sphenoid pneumatization, recesses and septations of the sinus, and other relevant anatomic variants. Radiologists should understand the relationships of the sphenoid bone and skull base structures, anatomic variants, and image-guided neuronavigation techniques to prevent surgical complications and allow effective treatment of skull base lesions with the endoscopic endonasal transsphenoidal approach. ©RSNA, 2015.
Sterilization, high-level disinfection, and environmental cleaning.
Rutala, William A; Weber, David J
2011-03-01
Failure to perform proper disinfection and sterilization of medical devices may lead to introduction of pathogens, resulting in infection. New techniques have been developed for achieving high-level disinfection and adequate environmental cleanliness. This article examines new technologies for sterilization and high-level disinfection of critical and semicritical items, respectively, and because semicritical items carry the greatest risk of infection, the authors discuss reprocessing semicritical items such as endoscopes and automated endoscope reprocessors, endocavitary probes, prostate biopsy probes, tonometers, laryngoscopes, and infrared coagulation devices. In addition, current issues and practices associated with environmental cleaning are reviewed. Copyright © 2011. Published by Elsevier Inc.
NASA Astrophysics Data System (ADS)
Zhao, Mengyuan; Yang, Zhuoqing; Xiang, Xiaojian; Sun, Bin; Ding, Guifu; Zhao, Xiaolin
2018-03-01
A single optic fiber scanner with large scanning angle, based on novel electromagnetic driven, is presented. The cylinder magnet and weight are fixed on the fiber, and vibrate under its second-order frequency by driving racetrack coils on the tube. The flexible driving coil is fabricated by uncomplicated planar MEMS technology on polyimide film, and wrapped on the tube. The electromagnetic and mechanical properties of the endoscope system are studied. Experimental results show that the maximum of the second resonant scanning angle is 9.47°.
CTA As an Adjuvant Tool for Acute Intra-abdominal or Gastrointestinal Bleeding.
Storace, Mitchell; Martin, Jonathan G; Shah, Jay; Bercu, Zachary
2017-12-01
Hematemesis and acute postsurgical upper gastrointestinal hemorrhage are common emergent on-call consultations for the interventional radiologist. Upper GI bleleding (UGIB) is a relatively frequent problem. The incidence and mortality vary among patient populations, but studies have shown an overall incidence ranging from 36-172 cases per 100,000 adults per year, with a mortality rate of 5%-14%. The incidence is significantly higher in men. Peptic ulcer disease is the predominant etiology, responsible for 28%-59% of UGIB. Other causes include varices, mucosal erosive disease, Mallory-Weiss syndrome, and malignancy. After assessment of hemodynamic status and airway stability with resuscitative efforts as needed, initial consultation with gastroenterology for endoscopic evaluation and treatment is well regarded as the initial therapeutic strategy. Angiography with embolization and interventional techniques directed at managing variceal hemorrhage have emerged as very capable second-line strategies for patients who have failed endoscopic therapy. In certain circumstances, the interventional radiologist may be called upon as the first line, notably for patients who have had recent surgical intervention or who have extraluminal hemorrhage. As the role of the interventional radiologist in the evaluation and treatment of UGIB continues to evolve, familiarity and knowledge of how to deal with these urgent and emergent clinical scenarios becomes paramount. Copyright © 2017 Elsevier Inc. All rights reserved.
2016-11-01
The aims of this prospective population-based cohort study were to identify the patient and hospital characteristics associated with emergency cholecystectomy, and the influences of these in determining variations between hospitals. Data were collected for consecutive patients undergoing cholecystectomy in acute UK and Irish hospitals between 1 March and 1 May 2014. Potential explanatory variables influencing the performance of emergency cholecystectomy were analysed by means of multilevel, multivariable logistic regression modelling using a two-level hierarchical structure with patients (level 1) nested within hospitals (level 2). Data were collected on 4744 cholecystectomies from 165 hospitals. Increasing age, lower ASA fitness grade, biliary colic, the need for further imaging (magnetic retrograde cholangiopancreatography), endoscopic interventions (endoscopic retrograde cholangiopancreatography) and admission to a non-biliary centre significantly reduced the likelihood of an emergency cholecystectomy being performed. The multilevel model was used to calculate the probability of receiving an emergency cholecystectomy for a woman aged 40 years or over with an ASA grade of I or II and a BMI of at least 25·0 kg/m 2 , who presented with acute cholecystitis with an ultrasound scan showing a thick-walled gallbladder and a normal common bile duct. The mean predicted probability of receiving an emergency cholecystectomy was 0·52 (95 per cent c.i. 0·45 to 0·57). The predicted probabilities ranged from 0·02 to 0·95 across the 165 hospitals, demonstrating significant variation between hospitals. Patients with similar characteristics presenting to different hospitals with acute gallbladder pathology do not receive comparable care. © 2016 BJS Society Ltd Published by John Wiley & Sons Ltd.
Legnani, G L; Rasini, M; Pastori, S; Sarli, D
2008-04-01
Inguinal hernioplasty has always been one of the most commonly performed operations in clinical practice. In the last 15 years, thanks to the development of mini-invasive surgery, new video-endoscopic techniques for the treatment of inguinal hernia using trans-peritoneal (TAPP) and extraperitoneal (TEP) access have emerged. Both have a definite role in the treatment of bilateral and recurrent hernias, while the debate is still open about the treatment of primary mono-lateral hernias. In acute incarcerated hernia requiring an emergency operation, the endoscopic approach is uncommon and controversial, and even considered contraindicated. The aim of this publication is to verify the efficacy and the technical feasibility of TAPP operation by analyzing a consecutive series of patients operated on for incarcerated inguino-crural hernia associated with suspected visceral ischemic lesion in an emergency setting. From September 2004 to October 2005, 13 patients were operated on acutely for inguino-crural incarcerated hernia associated with suspected visceral ischemic damage. Four were excluded from the endoscopic treatment due to anesthesiologic contraindications or huge hernia dimensions. Nine patients were operated on using a trans-peritoneal approach (TAPP). Visceral mobilization and hernia reduction were obtained by incision and opening of the hernia ring. Visceral resection was performed in one case with intestinal ischemia following a prolonged observation time or "test time." One case was associated with intestinal resection and incisional hernia repair, one with obturator hernia repair, and one with hepiployc appendix repair. None of the cases were converted to open technique, and no intra- or postoperative complications were recorded. Mean operative time was 72 min (35-180); mean hospital stay was 2.7 days (1-8). No recurrences were observed after a mean follow-up time of 18 months (8-24). The TAPP procedure can be proposed for emergency treatment of inguino-crural incarcerated hernias, allowing not only hernia correction, but also visual control and the contestual treatment of the hernia content. TAPP is a more challenging procedure compared to the traditional open anterior approach and therefore requires an adequate laparoscopic training. Exclusion criteria are constituted by anesthesiologic contraindications or dimensional criteria of the hernia.
Management of complex orbital fractures.
Bhatti, N; Kanzaria, A; Huxham-Owen, N; Bridle, C; Holmes, S
2016-09-01
The treatment of orbital injuries has evolved considerably over the last two decades. We describe strategies involved in the emergency management of orbital injuries, the use of imaging, preformed and customised materials for reconstruction, and endoscopic techniques. Copyright © 2016 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.
1988-08-01
1. All patients undergoing gastrointestinal endoscopy must be considered 'at risk' for HIV and appropriate cleaning/disinfection measures taken for endoscopes and accessories. 2. Thorough manual cleaning with detergent, of the instrument and its channels is the most important part of the cleaning/disinfection procedure. Without this, blood, mucus and organic material will prevent adequate penetration of disinfectant for inactivation of bacteria and viruses. 3. Aldehyde preparations (2% activated glutaraldehyde and related products) are the recommended first line antibacterial and antiviral disinfectant. A four minute soak is recommended as sufficient for inactivation of vegetative bacteria and viruses (including HIV and HBV). 4. Quaternary ammonium detergents (8% Dettox for two minutes for bacterial disinfection), followed by exposure of the endoscope shaft and channels to ethyl alcohol (70% for four minutes for viral inactivation), is an acceptable second-line disinfectant routine where staff sensitisation prevents the use of an aldehyde disinfectant. 5. Accessories, including mouthguards and cleaning brushes, require similarly careful cleaning/disinfection, before and after each use. Disposable products (especially injection needles) may be used and appropriate items can be sterilised by autoclaving and kept in sterile packs. 6. Closed circuit endoscope washing machines have advantages in maintaining standards and avoiding staff sensitisation to disinfectants. Improved ventilation including exhaust extraction facilities may be required. 7. Endoscopy staff should receive HBV vaccination, wear gloves and appropriate protective garments, cover wounds or abrasions and avoid needlestick injuries (including spiked forceps, etc). 8. Known HIV-infected or AIDS patients are managed as immunosuppressed, and require protection from atypical mycobacteria/cryptosporidia etc, by one hour aldehyde disinfection of endoscopic equipment before and after the procedure. A dedicated instrument is not required. 9. Increased funding is necessary for capital purchases of GI endoscopic equipment, including extra and immersible endoscopes with additional accessories to allow for safe practice. 10. Greater numbers of trained GI assistants are needed to ensure that cleaning/disinfection recommendations and safety precautions are followed, both during routine lists and emergency endoscopic procedures. 11. These recommendations are based on expert interpretation of current data on infectivity and disinfection; they may require future modification.
1988-01-01
1. All patients undergoing gastrointestinal endoscopy must be considered 'at risk' for HIV and appropriate cleaning/disinfection measures taken for endoscopes and accessories. 2. Thorough manual cleaning with detergent, of the instrument and its channels is the most important part of the cleaning/disinfection procedure. Without this, blood, mucus and organic material will prevent adequate penetration of disinfectant for inactivation of bacteria and viruses. 3. Aldehyde preparations (2% activated glutaraldehyde and related products) are the recommended first line antibacterial and antiviral disinfectant. A four minute soak is recommended as sufficient for inactivation of vegetative bacteria and viruses (including HIV and HBV). 4. Quaternary ammonium detergents (8% Dettox for two minutes for bacterial disinfection), followed by exposure of the endoscope shaft and channels to ethyl alcohol (70% for four minutes for viral inactivation), is an acceptable second-line disinfectant routine where staff sensitisation prevents the use of an aldehyde disinfectant. 5. Accessories, including mouthguards and cleaning brushes, require similarly careful cleaning/disinfection, before and after each use. Disposable products (especially injection needles) may be used and appropriate items can be sterilised by autoclaving and kept in sterile packs. 6. Closed circuit endoscope washing machines have advantages in maintaining standards and avoiding staff sensitisation to disinfectants. Improved ventilation including exhaust extraction facilities may be required. 7. Endoscopy staff should receive HBV vaccination, wear gloves and appropriate protective garments, cover wounds or abrasions and avoid needlestick injuries (including spiked forceps, etc). 8. Known HIV-infected or AIDS patients are managed as immunosuppressed, and require protection from atypical mycobacteria/cryptosporidia etc, by one hour aldehyde disinfection of endoscopic equipment before and after the procedure. A dedicated instrument is not required. 9. Increased funding is necessary for capital purchases of GI endoscopic equipment, including extra and immersible endoscopes with additional accessories to allow for safe practice. 10. Greater numbers of trained GI assistants are needed to ensure that cleaning/disinfection recommendations and safety precautions are followed, both during routine lists and emergency endoscopic procedures. 11. These recommendations are based on expert interpretation of current data on infectivity and disinfection; they may require future modification. PMID:3410338
The impact of new technology on surgery for colorectal cancer
Makin, Gregory B; Breen, David J; Monson, John RT
2001-01-01
Advances in technology continue at a rapid pace and affect all aspects of life, including surgery. We have reviewed some of these advances and the impact they are having on the investigation and management of colorectal cancer. Modern endoscopes, with magnifying, variable stiffness and localisation capabilities are making the primary investigation of colonic cancer easier and more acceptable for patients. Imaging investigations looking at primary, metastatic and recurrent disease are shifting to digital data sets, which can be stored, reviewed remotely, potentially fused with other modalities and reconstructed as 3 dimensional (3D) images for the purposes of advanced diagnostic interpretation and computer assisted surgery. They include virtual colonoscopy, trans-rectal ultrasound, magnetic resonance imaging, positron emission tomography and radioimmunoscintigraphy. Once a colorectal carcinoma is diagnosed, the treatment options available are expanding. Colonic stents are being used to relieve large bowel obstruction, either as a palliative measure or to improve the patient’s overall condition before definitive surgery. Transanal endoscopic microsurgery and minimally invasive techniques are being used with similar outcomes and a lower mortality, morbidity and hospital stay than open trans-abdominal surgery. Transanal endoscopic microsurgery allows precise excision of both benign and early malignant lesions in the mid and upper rectum. Survival of patients with inoperable hepatic metastases following radiofrequency ablation is encouraging. Robotics and telemedicine are taking surgery well into the 21st century. Artificial neural networks are being developed to enable us to predict the outcome for individual patients. New technology has a major impact on the way we practice surgery for colorectal cancer. PMID:11819841
Zandrino, F; Tettoni, S M; Gallesio, I; Summa, M
2017-01-01
The goal of this study was to retrospectively assess the efficacy of emergency percutaneous transcatheter arterial embolization in patients with severe bleeding due to upper gastrointestinal or jejunal tumor. Twelve patients (7 men, 5 women; mean age, 74 years±14 (SD); range: 54-86 years) with severe bleeding from the upper gastrointestinal tract, with failed endoscopic treatment not eligible for emergency surgery were treated by emergency percutaneous transcatheter arterial embolization. The bleeding cause was gastric tumor in 7 patients, duodenal tumor in 4 patients and jejunal tumor in one patient. Procedure details and follow-up were reviewed. Twelve embolization procedures were performed using various embolic agents. Embolization was achieved and bleeding was stopped in all patients. Five patients underwent surgery within the 30 days following embolization. In the remaining 7 patients, no bleeding occurred at 1 month follow-up in 6 patients and bleeding recurred in one patient at 1 month. In this later patient, endoscopic treatment was successful. The results of our study suggest that transcatheter arterial embolization is safe and effective in patients with severe arterial bleeding due to upper gastrointestinal or jejunal tumor. In some patients, transcatheter arterial embolization can be used as a bridge to surgery. Copyright © 2016 Éditions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.
Clinical management of achalasia: current state of the art
Krill, Joseph T; Naik, Rishi D; Vaezi, Michael F
2016-01-01
Achalasia is a primary disorder of esophageal motility. It classically presents with dysphagia to both solids and liquids but may be accompanied by regurgitation and chest pain. The gold standard for the diagnosis of achalasia is esophageal motility testing with manometry, which often reveals aperistalsis of the esophageal body and incomplete lower esophageal sphincter relaxation. The diagnosis is aided by complimentary tests, such as esophagogastroduodenoscopy and contrast radiography. Esophagogastroduodenoscopy is indicated to rule out mimickers of the disease known as “pseudoachalasia” (eg, malignancy). Endoscopic appearance of a dilated esophagus with retained food or saliva and a puckered lower esophageal sphincter should raise suspicion for achalasia. Additionally, barium esophagography may reveal a dilated esophagus with a distal tapering giving it a “bird’s beak” appearance. Multiple therapeutic modalities aid in the management of achalasia, the decision of which depends on operative risk factors. Conventional treatments include medical therapy, botulinum toxin injection, pneumatic dilation, and Heller myotomy. The last two are defined as the most definitive treatment options. New emerging therapies include peroral endoscopic myotomy, placement of self-expanding metallic stents, and endoscopic sclerotherapy. PMID:27110134
2017-01-01
Most gastrointestinal endoscopic procedures are now performed with sedation. Moderate sedation using benzodiazepines and opioids continue to be widely used, but propofol sedation is becoming more popular because its unique pharmacokinetic properties make endoscopy almost painless, with a very predictable and rapid recovery process. There is controversy as to whether propofol should be administered only by anesthesia professionals (monitored anesthesia care) or whether properly trained non-anesthesia personnel can use propofol safely via the modalities of nurse-administered propofol sedation, computer-assisted propofol sedation or nurse-administered continuous propofol sedation. The deployment of non-anesthesia administered propofol sedation for low-risk procedures allows for optimal allocation of scarce anesthesia resources, which can be more appropriately used for more complex cases. This can address some of the current shortages in anesthesia provider supply, and can potentially reduce overall health care costs without sacrificing sedation quality. This review will discuss efficacy, safety, efficiency, cost and satisfaction issues with various modes of sedation for non-advanced, non-emergent endoscopic procedures, mainly esophagogastroduodenoscopy and colonoscopy. PMID:29142513
Siiki, Antti; Sand, Juhani; Laukkarinen, Johanna
2018-05-18
Biodegradable self-expanding stents are an emerging alternative to standard biliary stents as the development of endoscopic insertion devices advances. The aim was to systematically review the existing literature on biodegradable biliary stents. In-vivo studies on the use of biodegradable stents in the biliary duct were systematically reviewed from 1990 to 2017. Despite extensive research on the biocompatibility of stents, the experience so far on their clinical use is limited. A few favorable reports have recently been presented on endoscopically and percutaneously inserted self-expanding biodegradable polydioxanone stents in benign biliary strictures. Another potential indication appears to be postcholecystectomy leak of the cystic duct. The main benefit of biodegradable stents is that stent removal can be avoided. The biocompatibility of the current biodegradable stent materials, most prominently polydioxanone, is well documented. In the few studies currently available, biodegradable stents are reported to be feasible and safe, also in humans. The initial results of the endoscopic use of these stents in benign biliary stricture management and for treating postcholecystectomy bile leaks are promising. Further controlled studies on long-term clinical results and cost-effectiveness are needed.
Use of Provocative Angiography to Localize Site in Recurrent Gastrointestinal Bleeding
DOE Office of Scientific and Technical Information (OSTI.GOV)
Johnston, Ciaran, E-mail: ciaranjohnston@yahoo.co.uk; Tuite, David; Pritchard, Ruth
2007-09-15
Background. While the source of most cases of lower gastrointestinal bleeding may be diagnosed with modern radiological and endoscopic techniques, approximately 5% of patients remain who have negative endoscopic and radiological investigations.Clinical Problem. These patients require repeated hospital admissions and blood transfusions, and may proceed to exploratory laparotomy and intraoperative endoscopy. The personal and financial costs are significant. Method of Diagnosis and Decision Making. The technique of adding pharmacologic agents (anticoagulants, vasodilators, fibrinolytics) during standard angiographic protocols to induce a prohemorrhagic state is termed provocative angiography. It is best employed when significant bleeding would otherwise necessitate emergency surgery. Treatment. Thismore » practice frequently identifies a bleeding source (reported success rates range from 29 to 80%), which may then be treated at the same session. We report the case of a patient with chronic lower gastrointestinal hemorrhage with consistently negative endoscopic and radiological workup, who had an occult source of bleeding identified only after a provocative angiographic protocol was instituted, and who underwent succeeding therapeutic coil embolization of the bleeding vessel.« less
Loffroy, Romaric F; Abualsaud, Basem A; Lin, Ming D; Rao, Pramod P
2011-01-01
Over the past two decades, transcatheter arterial embolization has become the first-line therapy for the management of upper gastrointestinal bleeding that is refractory to endoscopic hemostasis. Advances in catheter-based techniques and newer embolic agents, as well as recognition of the effectiveness of minimally invasive treatment options, have expanded the role of interventional radiology in the management of hemorrhage for a variety of indications, such as peptic ulcer bleeding, malignant disease, hemorrhagic Dieulafoy lesions and iatrogenic or trauma bleeding. Transcatheter interventions include the following: selective embolization of the feeding artery, sandwich coil occlusion of the gastroduodenal artery, blind or empiric embolization of the supposed bleeding vessel based on endoscopic findings and coil pseudoaneurysm or aneurysm embolization by three-dimensional sac packing with preservation of the parent artery. Transcatheter embolization is a fast, safe and effective, minimally invasive alternative to surgery when endoscopic treatment fails to control bleeding from the upper gastrointestinal tract. This article reviews the various transcatheter endovascular techniques and devices that are used in a variety of clinical scenarios for the management of hemorrhagic gastrointestinal emergencies. PMID:21860697
Lin, Chen-Sheng; Tung, Chun-Fang; Peng, Yen-Chun; Chow, Wei-Keung; Chang, Chi-Sen; Hu, Wei-Hsiung
2008-01-01
We report a case of gastric bezoar-induced gastric outlet obstruction that was successfully treated with a combination of endoscopic injection and irrigation with Coca Cola. A 73-year-old diabetic woman had a history of perforated peptic ulcer and had received pyloroplasty more than 20 years previously. She had been ingesting Pho Pu Zi (Cordia dichotoma Forst. f.) as an appetizer for 1 month. She presented with epigastric pain, nausea, and vomiting. Upper gastrointestinal endoscopy, performed at a local hospital, showed 2 gastric bezoars in the stomach, and 1 of them impacted at the pylorus. She was referred to our emergency department for removal of the gastric bezoars that were suspected to be causing gastric outlet obstruction. All attempts at endoscopic removal using a polypectomy snare, biopsy forceps and Dormia basket failed. We then injected Coca Cola directly into the bezoar mass, followed by irrigation with Coca Cola. Follow-up endoscopy was performed the next day, which revealed that the gastric bezoars had dissolved spontaneously.
Fast calibration of electromagnetically tracked oblique-viewing rigid endoscopes.
Liu, Xinyang; Rice, Christina E; Shekhar, Raj
2017-10-01
The oblique-viewing (i.e., angled) rigid endoscope is a commonly used tool in conventional endoscopic surgeries. The relative rotation between its two moveable parts, the telescope and the camera head, creates a rotation offset between the actual and the projection of an object in the camera image. A calibration method tailored to compensate such offset is needed. We developed a fast calibration method for oblique-viewing rigid endoscopes suitable for clinical use. In contrast to prior approaches based on optical tracking, we used electromagnetic (EM) tracking as the external tracking hardware to improve compactness and practicality. Two EM sensors were mounted on the telescope and the camera head, respectively, with considerations to minimize EM tracking errors. Single-image calibration was incorporated into the method, and a sterilizable plate, laser-marked with the calibration pattern, was also developed. Furthermore, we proposed a general algorithm to estimate the rotation center in the camera image. Formulas for updating the camera matrix in terms of clockwise and counterclockwise rotations were also developed. The proposed calibration method was validated using a conventional [Formula: see text], 5-mm laparoscope. Freehand calibrations were performed using the proposed method, and the calibration time averaged 2 min and 8 s. The calibration accuracy was evaluated in a simulated clinical setting with several surgical tools present in the magnetic field of EM tracking. The root-mean-square re-projection error averaged 4.9 pixel (range 2.4-8.5 pixel, with image resolution of [Formula: see text] for rotation angles ranged from [Formula: see text] to [Formula: see text]. We developed a method for fast and accurate calibration of oblique-viewing rigid endoscopes. The method was also designed to be performed in the operating room and will therefore support clinical translation of many emerging endoscopic computer-assisted surgical systems.
Prisman, Eitan; Daly, Michael J; Chan, Harley; Siewerdsen, Jeffrey H; Vescan, Allan; Irish, Jonathan C
2011-01-01
Custom software was developed to integrate intraoperative cone-beam computed tomography (CBCT) images with endoscopic video for surgical navigation and guidance. A cadaveric head was used to assess the accuracy and potential clinical utility of the following functionality: (1) real-time tracking of the endoscope in intraoperative 3-dimensional (3D) CBCT; (2) projecting an orthogonal reconstructed CBCT image, at or beyond the endoscope, which is parallel to the tip of the endoscope corresponding to the surgical plane; (3) virtual reality fusion of endoscopic video and 3D CBCT surface rendering; and (4) overlay of preoperatively defined contours of anatomical structures of interest. Anatomical landmarks were contoured in CBCT of a cadaveric head. An experienced endoscopic surgeon was oriented to the software and asked to rate the utility of the navigation software in carrying out predefined surgical tasks. Utility was evaluated using a rating scale for: (1) safely completing the task; and (2) potential for surgical training. Surgical tasks included: (1) uncinectomy; (2) ethmoidectomy; (3) sphenoidectomy/pituitary resection; and (4) clival resection. CBCT images were updated following each ablative task. As a teaching tool, the software was evaluated as "very useful" for all surgical tasks. Regarding safety and task completion, the software was evaluated as "no advantage" for task (1), "minimal" for task (2), and "very useful" for tasks (3) and (4). Landmark identification for structures behind bone was "very useful" for both categories. The software increased surgical confidence in safely completing challenging ablative tasks by presenting real-time image guidance for highly complex ablative procedures. In addition, such technology offers a valuable teaching aid to surgeons in training. Copyright © 2011 American Rhinologic Society-American Academy of Otolaryngic Allergy, LLC.
Karanikas, Michael; Touzopoulos, Panagiotis; Mitrakas, Alexandros; Zezos, Petros; Zarogoulidis, Paul; Machairiotis, Nikolaos; Efremidou, Eleni; Liratzopoulos, Nikolaos; Polychronidis, Alexandros; Kouklakis, George
2012-01-01
Post-radiation stricture is a rare complication after pelvis irradiation, but must be in the mind of the clinician evaluating a lower gastrointestinal obstruction. Endoscopy has gained an important role in chronic radiation proctitis with several therapeutic options for management of intestinal strictures. The treatment of rectal strictures has been limited to surgery with high morbidity and mortality. Therefore, a less invasive therapeutic approach for benign rectal strictures, endoscopic balloon dilation with or without intralesional steroid injection, has become a common treatment modality. We present a case of benign post-radiation rectal stricture treated successfully with balloon dilation and adjuvant intralesional triamcinolone injection. A 70-year-old woman presented to the emergency room complaining for 2 weeks of diarrhea and meteorism, 11 years after radiation of the pelvis due to adenocarcinoma of the uterus. Colonoscopy revealed a stricture at the rectum and multiple endoscopic biopsies were obtained from the stricture. The stricture was treated with endoscopic balloon dilation and intralesional triamcinolone injection. The procedure appears to have a high success rate and a very low complication rate. Histologic examination of the biopsies revealed non-specific inflammatory changes of the rectal mucosa and no specific changes of the mucosa due to radiation. All biopsies were negative for malignancy. The patient is stricture-free 12 months post-treatment. PMID:23271987
Damage-control laparoscopic partial cholecystectomy with an endoscopic linear stapler.
Özçınar, Beyza; Memişoğlu, Ecem; Gök, Ali Fuat Kaan; Ağcaoğlu, Orhan; Yanar, Fatih; İlhan, Mehmet; Yanar, Hakan Teoman; Günay, Kayıhan
2017-01-01
Several damage-control procedures have been described in the literature in case of severe Calot's triangle inflammation and fibrosis. In this report, we describe patients who underwent laparoscopic partial cholecystectomy using an endoscopic linear stapler. Five patients with acute cholecystitis underwent laparoscopic partial cholecystectomy in our clinic between January - December 2011. All patients had severe fibrosis and inflammation of Calot's triangle. The anterior and posterior walls of the gallbladder were totally resected if possible. The gallbladder was transected at its neck or Hartmann's pouch, leaving a remnant gallbladder pouch behind. Five patients had laparoscopic partial cholecystectomy with an endoscopic linear stapler. The main symptom of all patients on admission to the emergency room was abdominal pain. The mean time for the surgical procedure was 140 minutes (range, 120-180 minutes). Inflammation and fibrosis of Calot's triangle was detected in all patients during surgery and a phlegmonous gallbladder was detected in one patient. Surgical drains were used in all patients and no biliary leakage was detected. Remnant common bile duct calculi were detected in one patient and this patient underwent endoscopic retrograde cholangiopancreatography one month after surgery. When a reliable view of Calot's triangle cannot be obtained due to severe inflammation and fibrosis during laparoscopy, laparoscopic partial cholecystectomy seems to be a safe and feasible alternative to open surgery with an acceptable morbidity rate.
Extended Transsphenoidal Endoscopic Endonasal Surgery of Suprasellar Craniopharyngiomas.
Fomichev, Dmitry; Kalinin, Pavel; Kutin, Maxim; Sharipov, Oleg
2016-10-01
The endoscopic extended transsphenoidal approach for suprasellar craniopharyngiomas may be a really alternative to the transcranial approach in many cases. The authors present their experience with this technique in 136 patients with craniopharyngiomas. From the past 7 years 204 patients with different purely supradiaphragmatic tumors underwent removal by extended endoscopic transsphenoidal transtuberculum transplanum approach. Most of the patients (136) had craniopharyngiomas (suprasellar, intra-extraventricular). The patients were analyzed according to age, sex, tumor size, growth and tumor structure, and clinical symptoms. Twenty-five patients had undergone a previous surgery. The mean follow-up was 42 months (range, 4-120 months). The operation is always performed with the bilateral endoscopic endonasal anterior extended transsphenoidal approach. A gross-total removal was completed in 72%. Improvement of vision or absence of visual deterioration after operation was observed in 89% of patients; 11% had worsening vision after surgery. Endocrine dysfunction did not improve after surgery, new hypotalamopituitary dysfunction (anterior pituitary dysfunction or diabetes insipidus) or worsening of it was observed in 42.6%. Other main complications included transient new mental disorder in 11%, temporary neurological postoperative deficits in 3.7%, bacterial meningitis in 16%, cerebrospinal fluid leaks in 8.8%. The recurrence rate was 20% and the lethality was 5.8%. Resection of suprasellar craniopharyngiomas using the extended endoscopic approach is a more effective and less traumatic technology, able to provide resection of the tumor along with high quality of life after surgery, and relatively rare postoperative complications and mortality. Copyright © 2016 Elsevier Inc. All rights reserved.
Microelectromechanical-System-Based Variable-Focus Liquid Lens for Capsule Endoscopes
NASA Astrophysics Data System (ADS)
Seo, Sang Won; Han, Seungoh; Seo, Jun Ho; Kim, Young Mok; Kang, Moon Sik; Min, Nam Ki; Choi, Woo Beom; Sung, Man Young
2009-05-01
A liquid lens based on the electrowetting phenomenon was designed to be cylindrical to minimize dead area. The lens was fabricated with microelectromechanical-system (MEMS) technology using silicon thin film and wafer bonding processes. A multiple dielectric layer comprising Teflon, silicon nitride, and thermal oxide was formed on the cylinder wall. With a change of 11 Vrms in the applied bias, the lens module, including the fabricated liquid lens, showed a focal length change of approximately 166 mm. A capsule endoscope was assembled, including the lens module, and was successfully used to take images of a pig colon at various focal lengths.
Applications of optical fibers and miniature photonic elements in medical diagnostics
NASA Astrophysics Data System (ADS)
Blaszczak, Urszula; Gilewski, Marian; Gryko, Lukasz; Zajac, Andrzej; Kukwa, Andrzej; Kukwa, Wojciech
2014-05-01
Construction of endoscopes which are known for decades, in particular in small devices with the diameter of few millimetres, are based on the application of fibre optic imaging bundles or bundles of fibers in the illumination systems (usually with a halogen source). Cameras - CCD and CMOS - with the sensor size of less than 5 mm emerging commercially and high power LED solutions allow to design and construct modern endoscopes characterized by many innovative properties. These constructions offer higher resolution. They are also relatively cheaper especially in the context of the integration of the majority of the functions on a single chip. Mentioned features of the CMOS sensors reduce the cycle of introducing the newly developed instruments to the market. The paper includes a description of the concept of the endoscope with a miniature camera built on the basis of CMOS detector manufactured by Omni Vision. The set of LEDs located at the operator side works as the illuminating system. Fibre optic system and the lens of the camera are used in shaping the beam illuminating the observed tissue. Furthermore, to broaden the range of applications of the endoscope, the illuminator allows to control the spectral characteristics of emitted light. The paper presents the analysis of the basic parameters of the light-and-optical system of the endoscope. The possibility of adjusting the magnifications of the lens, the field of view of the camera and its spatial resolution is discussed. Special attention was drawn to the issues related to the selection of the light sources used for the illumination in terms of energy efficiency and the possibility of providing adjusting the colour of the emitted light in order to improve the quality of the image obtained by the camera.
Parodi, Andrea; De Ceglie, Antonella; De Luca, Luca; Conigliaro, Rita; Naspetti, Riccardo; Arpe, Paola; Coccia, Gianni; Conio, Massimo
2016-11-01
Compared to emergency surgery, self-expandable metallic stents are effective and safe when used as bridge-to-surgery (BTS) in operable patients with acute colorectal cancer obstruction. In this study, we report data on the new conformable colonic stents. To evaluate clinical effectiveness of conformable stents as BTS in patients with acute colorectal cancer obstruction. This was a retrospective study. The study was conducted at six Italian Endoscopic Units. Data about patients with acute malignant colorectal obstruction were collected between 2007 and 2012. All patients were treated with conformable stents as BTS. Technical success, clinical success, rate of primary anastomosis and colostomy, early and late complications were evaluated. Data about 88 patients (62 males) were reviewed in this study. Conformable SEMS were correctly deployed in 86 out of 88 patients, with resolution of obstruction in all treated patients. Tumor resection with primary anastomosis was possible in all patients. A temporary colostomy was performed in 40. Early complications did not occur. Late complications occurred in 11 patients. Stent migration was significantly higher in patients treated with partially-covered stents compared to the uncovered group (35% vs. 0%, P<0.001). Endoscopical re-intervention was required in 12% of patients. One patient with rectal cancer had an anastomotic dehiscence after surgery and he was successfully treated with endoscopic clipping. One year after surgery, all patients were alive and local recurrence have not been documented. This was a retrospective and uncontrolled study. Preliminary data from this large case series are encouraging, with a high rate of technical and clinical success and low rate of clinically relevant complications. Partially-covered SEMS should be avoided in order to reduce the risk of endoscopic re-intervention. Copyright © 2016. Published by Elsevier Masson SAS.
Berens, Angelique M; Harbison, Richard Alex; Li, Yangming; Bly, Randall A; Aghdasi, Nava; Ferreira, Manuel; Hannaford, Blake; Moe, Kris S
2017-08-01
To develop a method to measure intraoperative surgical instrument motion. This model will be applicable to the study of surgical instrument kinematics including surgical training, skill verification, and the development of surgical warning systems that detect aberrant instrument motion that may result in patient injury. We developed an algorithm to automate derivation of surgical instrument kinematics in an endoscopic endonasal skull base surgery model. Surgical instrument motion was recorded during a cadaveric endoscopic transnasal approach to the pituitary using a navigation system modified to record intraoperative time-stamped Euclidian coordinates and Euler angles. Microdebrider tip coordinates and angles were referenced to the cadaver's preoperative computed tomography scan allowing us to assess surgical instrument kinematics over time. A representative cadaveric endoscopic endonasal approach to the pituitary was performed to demonstrate feasibility of our algorithm for deriving surgical instrument kinematics. Technical feasibility of automatically measuring intraoperative surgical instrument motion and deriving kinematics measurements was demonstrated using standard navigation equipment.
Miniature Wireless BioSensor for Remote Endoscopic Monitoring
NASA Astrophysics Data System (ADS)
Nemiroski, Alex; Brown, Keith; Issadore, David; Westervelt, Robert; Thompson, Chris; Obstein, Keith; Laine, Michael
2009-03-01
We have built a miniature wireless biosensor with fluorescence detection capability that explores the miniaturization limit for a self-powered sensor device assembled from the latest off-the-shelf technology. The device is intended as a remote medical sensor to be inserted endoscopically and remainin a patient's gastrointestinal tract for a period of weeks, recording and transmitting data as necessary. A sensing network may be formed by using multiple such devices within the patient, routing information to an external receiver that communicates through existing mobilephone networks to relay data remotely. By using a monolithic IC chip with integrated processor, memory, and 2.4 GHz radio,combined with a photonic sensor and miniature battery, we have developed a fully functional computing device in a form factorcompliantwith insertion through the narrowest endoscopic channels (less than 3mm x 3mm x 20mm). We envision similar devices with various types of sensors to be used in many different areas of the human body.
NASA Astrophysics Data System (ADS)
Kapralov, S. V.; Shapkin, Y. G.; Lychagov, V. V.; Tuchin, V. V.
2007-05-01
One of the most complex problems of emergency surgery is the choice of surgical tactics to deal with bleeding peptic ulcer. Endoscopic hemostasis is prescribed to patients with continuing bleedings and prerelapse syndrome. But till nowdays the objective verification of the prerelapse condition had not been worked out. What is more there are no objective criteria to judge the effectiveness of the carried endohemostasis. The aim of the study was to work out a new objective diagnostic method of pre-recurrence syndrome that can be able to make prognosis for possible gastroduodenal ulcer bleeding recurrence more precise. Laser Doppler flowmetry was the method of studies the regional perfusion. The device used in this work was made at the Optics and Biophysics Department of Saratov State University.
Post-obstructive pulmonary edema from aspirated nuts.
Bashir, Ahsan; Ahmad, Sabina Qureshi; Silverman, Joshua; Concepcion, Emily; Lee, Haesoon
2017-01-01
Post-obstructive pulmonary edema is thought to occur from hemodynamic changes secondary to forced inspiration against the closed airway due to acute or chronic airway obstruction. We report a case of a 13 month-old boy who developed pulmonary edema from aspirated foreign body, nuts. He underwent emergency bronchoscopy to confirm the clinical diagnosis of aspirated nuts in the trachea and nuts were removed endoscopically. His trachea was then intubated and he was mechanically ventilated with oxygen. He developed florid pulmonary edema early in the course with tracheal obstruction and during endoscopic removal of nuts. After removal of obstruction he was ventilated mechanically and pulmonary edema cleared rapidly. Aspirated nuts obstructing trachea can induce obstructive pulmonary edema. Early recognition of foreign body obstruction based on clinical history and its removal resolved pulmonary edema.
Malignant central airway obstruction
Mudambi, Lakshmi; Miller, Russell
2017-01-01
This review comprehensively describes recent advances in the management of malignant central airway obstruction (CAO). Malignant CAO can be a dramatic and devastating manifestation of primary lung cancer or metastatic disease. A variety of diagnostic modalities are available to provide valuable information to plan a therapeutic intervention. Clinical heterogeneity in the presentation of malignant CAO provides opportunities to adapt and utilize endoscopic technology and tools in many ways. Mechanical debulking, thermal tools, cryotherapy and airway stents are methods and instruments used to rapidly restore airway patency. Delayed bronchoscopic methods, such as photodynamic therapy (PDT) and brachytherapy can also be utilized in specific non-emergent situations to establish airway patency. Although data regarding the success and complications of therapeutic interventions are retrospective and characterized by clinical and outcome measure variability, the symptoms of malignant CAO can often be successfully palliated. Assessment of risks and benefits of interventions in each individual patient during the decision-making process forms the critical foundation of the management of malignant CAO. PMID:29214067
Lakhtakia, Sundeep
2017-01-01
Pancreatic neuroendocrine tumors (PNETs) are increasingly being detected, though usually as incidental findings. Majority of the PNETs are non-functional and surgical resection is the standard of care for most of them. However, in patients with small PNETs localized within the pancreas, who are unfit or unwilling for surgery, alternate methods of treatment are needed. Direct methods of ablation of PNETs, using either ethanol injection or radiofrequency ablation (RFA), are emerging as effective methods. The limited literature available as case reports or case series on endoscopic ultrasound (EUS)-guided local ablation using either ethanol or RFA has demonstrated safety and efficacy along with short- to medium-term sustained relief. Long-term benefits with these local ablative therapies are awaited. Comparative studies are needed to show which of these two competing technologies is superior. Finally, comparative trials of EUS-guided ablation with surgical resection in terms of efficacy and safety will ensure their place in the management algorithm. PMID:29207860
Virtual endoscopy in neurosurgery: a review.
Neubauer, André; Wolfsberger, Stefan
2013-01-01
Virtual endoscopy is the computerized creation of images depicting the inside of patient anatomy reconstructed in a virtual reality environment. It permits interactive, noninvasive, 3-dimensional visual inspection of anatomical cavities or vessels. This can aid in diagnostics, potentially replacing an actual endoscopic procedure, and help in the preparation of a surgical intervention by bridging the gap between plain 2-dimensional radiologic images and the 3-dimensional depiction of anatomy during actual endoscopy. If not only the endoscopic vision but also endoscopic handling, including realistic haptic feedback, is simulated, virtual endoscopy can be an effective training tool for novice surgeons. In neurosurgery, the main fields of the application of virtual endoscopy are third ventriculostomy, endonasal surgery, and the evaluation of pathologies in cerebral blood vessels. Progress in this very active field of research is achieved through cooperation between the technical and the medical communities. While the technology advances and new methods for modeling, reconstruction, and simulation are being developed, clinicians evaluate existing simulators, steer the development of new ones, and explore new fields of application. This review introduces some of the most interesting virtual reality systems for endoscopic neurosurgery developed in recent years and presents clinical studies conducted either on areas of application or specific systems. In addition, benefits and limitations of single products and simulated neuroendoscopy in general are pointed out.
Mizutani, Hiroya; Ono, Satoshi; Ushiku, Tetsuo; Kudo, Yotaro; Ikemura, Masako; Kageyama, Natsuko; Yamamichi, Nobutake; Fujishiro, Mitsuhiro; Someya, Takao; Fukayama, Masashi; Koike, Kazuhiko; Onodera, Hiroshi
2018-02-01
Although high-resolution three-dimensional imaging of endoscopically resected gastrointestinal specimens can help elucidating morphological features of gastrointestinal mucosa or tumor, there are no established methods to achieve this without breaking specimens apart. We evaluated the utility of transparency-enhancing technology for three-dimensional assessment of gastrointestinal mucosa in porcine models. Esophagus, stomach, and colon mucosa samples obtained from a sacrificed swine were formalin-fixed and paraffin-embedded, and subsequently deparaffinized for analysis. The samples were fluorescently stained, optically cleared using transparency-enhancing technology: ilLUmination of Cleared organs to IDentify target molecules method (LUCID), and visualized using laser scanning microscopy. After observation, all specimens were paraffin-embedded again and evaluated by conventional histopathological assessment to measure the impact of transparency-enhancing procedures. As a result, microscopic observation revealed horizontal section views of mucosa at deeper levels and enabled the three-dimensional image reconstruction of glandular and vascular structures. Besides, paraffin-embedded specimens after transparency-enhancing procedures were all assessed appropriately by conventional histopathological staining. These results suggest that transparency-enhancing technology may be feasible for clinical application and enable the three-dimensional structural analysis of endoscopic resected specimen non-destructively. Although there remain many limitations or problems to be solved, this promising technology might represent a novel histopathological method for evaluating gastrointestinal cancers. © 2018 Japanese Society of Pathology and John Wiley & Sons Australia, Ltd.
In vivo miniature robots for natural orifice surgery: State of the art and future perspectives.
Tiwari, Manish M; Reynoso, Jason F; Lehman, Amy C; Tsang, Albert W; Farritor, Shane M; Oleynikov, Dmitry
2010-06-27
Natural orifice translumenal endoscopic surgery (NOTES) is the integration of laparoscopic minimally invasive surgery techniques with endoscopic technology. Despite the advances in NOTES technology, the approach presents several unique instrumentation and technique-specific challenges. Current flexible endoscopy platforms for NOTES have several drawbacks including limited stability, triangulation and dexterity, and lack of adequate visualization, suggesting the need for new and improved instrumentation for this approach. Much of the current focus is on the development of flexible endoscopy platforms that incorporate robotic technology. An alternative approach to access the abdominal viscera for either a laparoscopic or NOTES procedure is the use of small robotic devices that can be implanted in an intracorporeal manner. Multiple, independent, miniature robots can be simultaneously inserted into the abdominal cavity to provide a robotic platform for NOTES surgery. The capabilities of the robots include imaging, retraction, tissue and organ manipulation, and precise maneuverability in the abdominal cavity. Such a platform affords several advantages including enhanced visualization, better surgical dexterity and improved triangulation for NOTES. This review discusses the current status and future perspectives of this novel miniature robotics platform for the NOTES approach. Although these technologies are still in pre-clinical development, a miniature robotics platform provides a unique method for addressing the limitations of minimally invasive surgery, and NOTES in particular.
NASA Technical Reports Server (NTRS)
2004-01-01
NASA's Hubble Space Telescope has given the world amazing images of the distant stars, planets, and galaxies. The cutting-edge imaging technology that enhances the Hubble images also extends its benefits to life here on Earth, from deciphering previously unreadable portions of the Dead Sea Scrolls to improving digital mammographies for advanced cancer detection. This imaging technology is now helping physicians to perform micro-invasive arthroscopic surgery, which is the visual examination of an interior joint such as the knee. In 1997, NASA's Glenn Research Center signed a Space Act Agreement with Micro Medical Devices, Inc. (MMD), a medical device engineering company that licenses miniature surgical devices. At that time, MMD was in the process of developing a new micro-endoscope. This tool enables surgeons to view what is happening inside the body on a screen, eliminating the need for a more invasive diagnostic procedure. The images from the micro-endoscope needed to be extremely clear, a challenge with the tool s small size. The images also needed to be viewed in real time to allow surgeons to see what was happening in the body at that very moment. MMD established Clear Image Technology, LLC, of Elyria, Ohio, to commercialize the miniature endoscope. Clear Image Technology then partnered with Arthrotek, Inc., a sports medicine subsidiary of Biomet, Inc., to introduce the tool to the commercial market as the InnerVue[TM] Diagnostic Scope System. The InnerVue system is designed for use in a diagnostic environment, such as an office or outpatient service, to evaluate conditions within a joint. While the InnerVue scope is primarily being applied to the knee and shoulder, other small joints such as the wrist, elbow, and ankle are being investigated. A physician can use the system alone or in conjunction with magnetic resonance imaging (MRI) to determine the next treatment step for each patient. The procedure can be more accurate than MRI, particularly with diagnosing cartilage and articular surface damage and assessing arthritis severity.
Santander-Flores, Selene Artemisa; Mata-Quintero, Carlos Javier; O'Farrill-Anzures, Ricardo; González-Villegas, Paloma; Calvo-Vázquez, Iván; Campos-Serna, Esteban Israel
Foreign body ingestion is the second cause of endoscopic emergency in the elderly, and dentures are the most frequent accidently ingested objects. Once in the stomach, their expulsion can be expected in 4 to 6 days. The treatment is wait and see in asymptomatic patients, but preventive endoscopic removal can also be performed. To present 2 scenarios of the outcome and treatment in patients with foreign body ingestion. Patient under study due to weight loss, with a denture detected by abdominal x-ray, ingested inadvertently a year ago. A laparotomy was required as extraction by colonoscopy failed, due to excessive inflammation. The second case, of 24-hour onset, was due to the ingestion of a partial denture. As duodenal endoscopy extraction was unsuccessful, the patient was kept under observation. When it did not pass the caecum, it was extracted by colonoscopy, with no further complications and shorter hospital stay. Follow-up can be by simple abdominal x-ray, with endoscopic management if there is insufficient progress. In one of our cases, the outcome was unfavourable due to time of ingestion, and endoscopic management was not possible, whereas in the second case colonoscopy was performed early with success. Proper diagnostic and timely treatment mark the difference in the progression and outcome of the ingestion of foreign bodies. Copyright © 2016 Academia Mexicana de Cirugía A.C. Publicado por Masson Doyma México S.A. All rights reserved.
Obinwa, Obinna; Cooper, David; O'Riordan, James M
2016-01-01
This case report is intended to inform clinicians, endoscopists, policy makers and industry of our experience in the management of a rare case of mobile phone ingestion. A 29-year-old prisoner presented to the Emergency Department with vomiting, ten hours after he claimed to have swallowed a mobile phone. Clinical examination was unremarkable. Both initial and repeat abdominal radiographs eight hours later confirmed that the foreign body remained in situ in the stomach and had not progressed along the gastrointestinal tract. Based on these findings, upper endoscopy was performed under general anaesthesia. The object could not be aligned correctly to accommodate endoscopic removal using current retrieval devices. Following unsuccessful endoscopy, an upper midline laparotomy was performed and the phone was delivered through an anterior gastrotomy, away from the pylorus. The patient made an uneventful recovery and underwent psychological counselling prior to discharge. In this case report, the use of endoscopy in the management when a conservative approach fails is questioned. Can the current endoscopic retrieval devices be improved to limit the need for surgical interventions in future cases? An ingested mobile phone in the stomach may not be amenable for removal using the current endoscopic retrieval devices. Improvements in overtubes or additional modifications of existing retrieval devices to ensure adequate alignment for removal without injuring the oesophagus are needed. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.
Murdani, Abdullah; Kumar, Ajay; Chiu, Han-Mo; Goh, Khean-Lee; Jang, Byung Ik; Khor, Christopher J L; Lau, James; Mostafa, Ibrahim; Ramchandani, Mohan; Ratanalert, Siriporn; Tajiri, Hisao; Yuen, Minghwa; Zhang, Shu Tian; Duforest-Rey, Dianelle; Rey, Jean-Francois
2017-01-01
The aim of this position statement is to reinforce the key points of hygiene in digestive endoscopy. The present article details the minimum hygiene requirements for reprocessing of endoscopes and endoscopic devices, regardless of the reprocessing method (automated washer-disinfector or manual cleaning) and the endoscopy setting (endoscopy suite, operating room, elective or emergency procedures). These minimum requirements are mandatory for patient safety. Both advanced diagnostic and therapeutic endoscopies should be carried out in an environment that is safe for patients and staff. Particular attention is given to contaminants. Procedural errors in decontamination, defective equipment, and failure to follow disinfection guidelines are major factors contributing to transmission of infection during endoscopy. Other important risk factors include inadequate cleaning, use of older endoscopes with surface and working channel irregularities, and contamination of water bottles or irrigating solutions. Infections by multidrug-resistant organisms have become an increasing problem in health-care systems worldwide. Since 2010, outbreaks of multidrug-resistant bacteria associated with endoscopic retrograde cholangiopancreatography have been reported from the USA, France, Germany, and The Netherlands. In many endoscopy units in Asia and the Middle East, reprocessing procedures have lagged behind those of Western countries for cultural reasons or lack of financial resources. This inconsistency in standards is now being addressed, and the World Endoscopy Organization has prepared this position statement to highlight key points for quality assurance in any endoscopy unit in any country. © 2016 Japan Gastroenterological Endoscopy Society.
Varshney, Rickul; Frenkiel, Saul; Nguyen, Lily H P; Young, Meredith; Del Maestro, Rolando; Zeitouni, Anthony; Tewfik, Marc A
2014-01-01
The technical challenges of endoscopic sinus surgery (ESS) and the high risk of complications support the development of alternative modalities to train residents in these procedures. Virtual reality simulation is becoming a useful tool for training the skills necessary for minimally invasive surgery; however, there are currently no ESS virtual reality simulators available with valid evidence supporting their use in resident education. Our aim was to develop a new rhinology simulator, as well as to define potential performance metrics for trainee assessment. The McGill simulator for endoscopic sinus surgery (MSESS), a new sinus surgery virtual reality simulator with haptic feedback, was developed (a collaboration between the McGill University Department of Otolaryngology-Head and Neck Surgery, the Montreal Neurologic Institute Simulation Lab, and the National Research Council of Canada). A panel of experts in education, performance assessment, rhinology, and skull base surgery convened to identify core technical abilities that would need to be taught by the simulator, as well as performance metrics to be developed and captured. The MSESS allows the user to perform basic sinus surgery skills, such as an ethmoidectomy and sphenoidotomy, through the use of endoscopic tools in a virtual nasal model. The performance metrics were developed by an expert panel and include measurements of safety, quality, and efficiency of the procedure. The MSESS incorporates novel technological advancements to create a realistic platform for trainees. To our knowledge, this is the first simulator to combine novel tools such as the endonasal wash and elaborate anatomic deformity with advanced performance metrics for ESS.
Gupta, Rajesh; Reddy, D Nageshwar
2011-09-01
Endoscopic stenting is an effective treatment option in the management of both benign biliary strictures and pancreatic ductal strictures. Plastic stents and self-expandable metal stents have been used with variable success for the management of both benign biliary strictures and pancreatic ductal strictures caused by chronic pancreatitis. Fully covered self-expandable metal stents of improved design represent a major technological advance which has added to the endoscopic armamentarium. Both multiple plastic stents and covered self-expandable metal stents have shown promising results. However, data to support the use of self-expandable metal stents over multiple plastic stents or vice versa are still lacking.
Monitored transoral endoscopic thyroidectomy via long monopolar stimulation probe.
Dionigi, Gianlorenzo; Wu, Che-Wei; Tufano, Ralph P; Rizzo, Antonio Giacomo; Anuwong, Angkoon; Sun, Hui; Carcoforo, Paolo; Antonino, Cancellieri; Portinari, Mattia; Kim, Hoon Yub
2018-01-01
This video aimed to describe the role of intraoperative neuromonitoring (IONM) during transoral endoscopic thyroidectomy vestibular approach (TOETVA) with emphasis given to IONM technical and technological notes, the identification of recurrent laryngeal nerve (RLN). Standardized technique of IONM consist in identifying and monitoring both the vagus nerve and the RLNs before and after resection (V1, V2, R1, R2). According to this report, IONM during TOETVA is feasible and safe in providing identification and function of laryngeal nerves. IONM enable surgeons to feel more comfortable with their initial approach to TOETVA or extended indications. Larger series are needed for appropriated evaluation of IONM in reduction of the rates for RLN complications.
Monitored transoral endoscopic thyroidectomy via long monopolar stimulation probe
Wu, Che-Wei; Tufano, Ralph P.; Rizzo, Antonio Giacomo; Anuwong, Angkoon; Sun, Hui; Carcoforo, Paolo; Antonino, Cancellieri; Portinari, Mattia; Kim, Hoon Yub
2018-01-01
This video aimed to describe the role of intraoperative neuromonitoring (IONM) during transoral endoscopic thyroidectomy vestibular approach (TOETVA) with emphasis given to IONM technical and technological notes, the identification of recurrent laryngeal nerve (RLN). Standardized technique of IONM consist in identifying and monitoring both the vagus nerve and the RLNs before and after resection (V1, V2, R1, R2). According to this report, IONM during TOETVA is feasible and safe in providing identification and function of laryngeal nerves. IONM enable surgeons to feel more comfortable with their initial approach to TOETVA or extended indications. Larger series are needed for appropriated evaluation of IONM in reduction of the rates for RLN complications. PMID:29445610
Endoscopy in neuro-otologic surgery.
Wackym, Phillip A; King, Wesley A; Meyer, Glenn A; Poe, Dennis S
2002-04-01
Endoscopy offers several distinct advantages over the operating microscope during neuro-otologic surgery that make it an excellent adjunctive tool to the microscope or independent modality during cranial base surgery. The high magnification gives excellent definition of perforating blood vessels, cranial nerves, and neural structures, which in many cases is superior to that achieved with the microscope. Furthermore, the use of angled or flexible endoscopes allows one to look around corners and behind anatomic structures blocking the view seen via a 0 degree microscope. Endoscopy also has the theoretical advantage that a less invasive operative procedure is required, which should reduce the operative morbidity. Several notable disadvantages of endoscopy include the problems associated with blood soiling the endoscope, making visualization difficult or impossible, the lack of readily available instrumentation designed specifically for endoscopic neuro-otology, and the poor overview of the operative field. This last point is an important one because the endoscope is placed adjacent to the lesion and does not allow one to look backward to prevent [figure: see text] injury to structures next to the shaft of the telescope. Furthermore, the surgeon must be cognizant of potential thermal injury to structures caused by the heat generated by the light source. The present endoscopic technology limits the image that the surgeon sees to two dimensions, which results in certain unique problems when operating in a three-dimensional milieu. Because of this, there is a steep learning curve to acquire endoscopic dexterity and three-dimensional orientation. Finally, bimanual operation requires the use of an articulated endoscope holder or the commitment of the co-surgeon to hold the endoscope. One of the limitations of the operative microscope is that the angle of view is determined by the distance of the lens to the skull, retractor, or obstructing tissue, which is a function of the lens focal length; the longer the focal length, the narrower the viewing angle. During most microsurgical procedures, the focal distance varies between 200 and 400 mm. Using a previous analogy, if one looks through a door's keyhole at close range, nearly the entire room on the opposite side of the door can be seen, although nothing can be seen when the hole is viewed from a long distance. This is similar to what happens when using the endoscope with focal lengths ranging from 5 to 20 mm: a wider angle of view can be achieved. Based on their, experience the authors believe that endoscopes can be used safely during neuro-otologic surgery. As an adjunct to or substitution for the operative microscope, this modality does improve visualization of bony, neural, and vascular structures while minimizing cerebellar retraction.
Upper gastrointestinal bleeding.
Feinman, Marcie; Haut, Elliott R
2014-02-01
Upper gastrointestinal (GI) bleeding remains a commonly encountered diagnosis for acute care surgeons. Initial stabilization and resuscitation of patients is imperative. Stable patients can have initiation of medical therapy and localization of the bleeding, whereas persistently unstable patients require emergent endoscopic or operative intervention. Minimally invasive techniques have surpassed surgery as the treatment of choice for most upper GI bleeding. Copyright © 2014 Elsevier Inc. All rights reserved.
Management of the colonic volvulus in 2016.
Perrot, L; Fohlen, A; Alves, A; Lubrano, J
2016-06-01
Colonic volvulus is the third leading cause of colonic obstruction worldwide, occurring at two principal locations: the sigmoid colon and cecum. In Western countries, sigmoid volvulus preferentially affects elderly men whereas cecal volvulus affects younger women. Some risk factors, such as chronic constipation, high-fiber diet, frequent use of laxatives, personal past history of laparotomy and anatomic predispositions, are common to both locations. Clinical symptomatology is non-specific, including a combination of abdominal pain, gaseous distention, and bowel obstruction. Abdominopelvic computerized tomography is currently the gold standard examination, allowing positive diagnosis as well as detection of complications. Specific management depends on the location, patient comorbidities and colonic wall viability, but treatment is an emergency in every case. If clinical or radiological signs of gravity are present, emergency surgery is mandatory, but is associated with high morbidity and mortality rates. For sigmoid volvulus without criteria of gravity, the ideal strategy is an endoscopic detorsion procedure followed, within 2 to 5 days, by surgery that includes a sigmoid colectomy with primary anastomosis. Exclusively endoscopic therapy must be reserved for patients who are at excessive risk for surgical intervention. In cecal volvulus, endoscopy has no role and surgery is the rule. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
Angiographic evaluation and management of acute gastrointestinal hemorrhage
Walker, T Gregory; Salazar, Gloria M; Waltman, Arthur C
2012-01-01
Although most cases of acute nonvariceal gastrointestinal hemorrhage either spontaneously resolve or respond to medical management or endoscopic treatment, there are still a significant number of patients who require emergency angiography and transcatheter treatment. Evaluation with noninvasive imaging such as nuclear scintigraphy or computed tomography may localize the bleeding source and/or confirm active hemorrhage prior to angiography. Any angiographic evaluation should begin with selective catheterization of the artery supplying the most likely site of bleeding, as determined by the available clinical, endoscopic and imaging data. If a hemorrhage source is identified, superselective catheterization followed by transcatheter microcoil embolization is usually the most effective means of successfully controlling hemorrhage while minimizing potential complications. This is now well-recognized as a viable and safe alternative to emergency surgery. In selected situations transcatheter intra-arterial infusion of vasopressin may also be useful in controlling acute gastrointestinal bleeding. One must be aware of the various side effects and potential complications associated with this treatment, however, and recognize the high re-bleeding rate. In this article we review the current role of angiography, transcatheter arterial embolization and infusion therapy in the evaluation and management of nonvariceal gastrointestinal hemorrhage. PMID:22468082
Monopolar soft-mode coagulation using hemostatic forceps for peptic ulcer bleeding.
Yamasaki, Yasushi; Takenaka, Ryuta; Nunoue, Tomokazu; Kono, Yoshiyasu; Takemoto, Koji; Taira, Akihiko; Tsugeno, Hirofumi; Fujiki, Shigeatsu
2014-01-01
Upper gastrointestinal hemorrhage from bleeding peptic ulcer is sometimes difficult to treat by conventional endoscopic methods. Recently, monopolar electrocoagulation using a soft-coagulation system and hemostatic forceps (soft coagulation) has been used to prevent bleeding during endoscopic submucosal dissection. The aim of this study was to assess the safety and efficacy of soft coagulation in the treatment of bleeding peptic ulcer. A total of 39 patients with peptic ulcers were treated using soft coagulation at our hospital between January 2005 and March 2010. Emergency treatment employed an ERBE soft-mode coagulation system using hemostatic forceps. Second-look endoscopy was performed to evaluate the efficacy of prior therapy. Initial hemostasis was defined as accomplished by soft coagulation, with or without other endoscopic therapy prior to soft coagulation. The rate of initial hemostasis, rebleeding, and ultimate hemostasis were retrospectively analyzed. The study subjects were 31 men and 8 women with a mean age of 68.3±13.7 years, with 29 gastric ulcers and 10 duodenal ulcers. Initial hemostasis was achieved in 37 patients (95%). During follow-up, bleeding recurred in two patients, who were retreated with soft coagulation. The monopolar soft coagulation is feasible and safe for treating bleeding peptic ulcers.
Endoscopic management of bilateral vocal fold paralysis in newborns and infants.
Sedaghat, Sahba; Tapia, Mario; Fredes, Felipe; Rojas, Pablo
2017-06-01
Bilateral vocal cord paralysis in adducted position (BVCPAd) is a severe cause of airway obstruction and usually debuts with stridor and airway distress necessitating immediate intervention. Tracheostomy has long been the gold standard for treating this condition, but has significant associated morbidity and mortality in pediatric patients. New conservative procedures have emerged to treat this condition thus avoiding tracheostomy, like endoscopic anterior and posterior cricoid split (EAPCS). The objective of this paper was to review our experience with EAPCS in newborns and infants. Prospective study involving patients undergoing endoscopic EAPCS for symptomatic BVCPAd. The primary outcomes were tracheostomy avoidance and resolution of airway symptoms. Three patients underwent EAPCS between January 2016 and December 2016. All patients stayed at least 7 days in the Intensive Care Unit (ICU) intubated. All patients presented complete resolution of their symptoms due to airway obstruction, without the need for tracheostomy. EAPCS is a novel and effective alternative to treat BVCPAd in patients under 1 year old. Our study is an initial experience; more cases are required to identify the real impact and benefits of this technique and to determine the proper selection of patients. Copyright © 2017 Elsevier B.V. All rights reserved.
Lv, Yun-Xiao; Yu, Cheng-Chan; Tung, Chun-Fang; Wu, Cheng-Chung
2014-06-10
Gossypiboma is a term used to describe a mass that forms around a cotton sponge or abdominal compress accidentally left in a patient during surgery. Transmural migration of an intra-abdominal gossypiboma has been reported to occur in the digestive tract, bladder, vagina and diaphragm. Open surgery is the most common approach in the treatment of gossypiboma. However, gossypibomas can be extracted by endoscopy while migrating into the digestive tract. We report a case of intractable duodenal ulcer caused by transmural migration of gossypiboma successfully treated by duodenorrhaphy. A systemic literature review is provided and a scheme of the therapeutic approach is proposed. A 61-year-old Han Chinese man presented with intermittent epigastric pain for the last 10 months. He had undergone laparoscopic cholecystectomy conversion to open cholecystectomy for acute gangrenous cholecystitis 10 months ago at another hospital. Transmural migration of gossypiboma into the duodenum was found. Endoscopic intervention failed to remove the entire gauze, and duodenal ulcer caused by the gauze persisted. Surgical intervention was performed and the gauze was removed successfully. The penetrated ulcer was repaired with duodenorrhaphy. The postoperative period was uneventful.We systematically reviewed the literature on transmural migration of gossypiboma into duodenum and present an overview of published cases. Our PubMed search yielded seven reports of transmural migration of retained surgical sponge into the duodenum. Surgical interventions were necessary in two patients. Transmural migration of gossypiboma into the duodenum is a rare surgical complication. The treatment strategies include endoscopic extraction and surgical intervention. Prompt surgical intervention should be considered for emergent conditions such as active bleeding, gastrointestinal obstruction, or intra-abdominal sepsis. For non-emergent conditions, surgical intervention could be considered for intractable cases in which endoscopic extraction failed.
A study of clinical and endoscopic profile of acute upper, gastrointestinal bleeding.
Dewan, K R; Patowary, B S; Bhattarai, S
2014-01-01
Acute Upper Gastrointestinal Bleeding is a common medical emergency with a hospital mortality of approximately 10 percent. Higher mortality rate is associated with rebleeding. Rockall scoring system identifies patients at higher risk of rebleed and mortality. To study the clinical and endoscopic profile of acute upper gastrointestinal bleed to know the etiology, clinical presentation, severity of bleeding and outcome. This is a prospective, descriptive hospital based study conducted in Gastroenterology unit of College of Medical Sciences and Teaching Hospital, Bharatpur, Nepal from January 2012 to January 2013. It included 120 patients at random presenting with manifestations of upper gastrointestinal bleed. Their clinical and endoscopic profiles were studied. Rockall scoring system was used to assess their prognosis. Males were predominant (75%). Age ranged from 14 to 88 years, mean being 48.76+17.19. At presentation 86 patients (71.7%) had both hematemesis and malena, 24 patients (20%) had only malena and 10 patients (8.3%) had only hematemesis. Shock was detected in 21.7%, severe anemia and high blood urea were found in 34.2% and 38.3% respectively. Upper Gastrointestinal Bleeding endoscopy revealed esophageal varices (47.5%), peptic ulcer disease (33.3%), erosive mucosal disease (11.6%), Mallory Weiss tear (4.1%) and malignancy (3.3%). Median hospital stay was 7.28+3.18 days. Comorbidities were present in 43.3%. Eighty six patients (71.7%) had Rockall score < 5 and 34 (28.3%) had >6. Five patients (4.2%) expired. Risk factors for death being massive rebleeeding, comorbidities and Rockall score >6. Acute Upper Gastrointestinal bleeding is a medical emergency. Mortality is associated with massive bleeding, comorbidities and Rockall score >6. Urgent, appropriate hospital management definitely helps to reduce morbidity and mortality.
Center for Integration of Medicine and Innovative Technology. Addendum
2009-10-01
development in biomaterials , endoscopic tools, energy delivery, medical imaging, and other novel technologies. 15. SUBJECT TERMS None provided. 16. SECURITY...below. Issues of Concern We have identified a suitable colla borator to conclude the second an d final phase of this project, namely Dr. Gary...patent application will depend on the results of the second phase of t he project, as well as the ex isting int ellectual property on SEE-fitted
Piriformis Syndrome and Endoscopic Sciatic Neurolysis.
Knudsen, Joshua S; Mei-Dan, Omer; Brick, Mathew J
2016-03-01
Piriformis syndrome is the compression or the irritation of the sciatic nerve by the adjacent piriformis muscle in the buttock leading to symptoms that include buttock pain, leg pain, and altered neurology in the sciatic nerve distribution. Epidemiological figures of the prevalence are unknown, but are estimated to be about 12.2% to 27%. There is no consensus on the diagnostic criteria. Advancement in magnetic resonance imaging allows us to observe unilateral hyperintensity and bowing of the sciatic nerve. The pathophysiology of the disease includes single blunt trauma, overuse causing piriformis hypertrophy, and long-term microtrauma causing scarring. Treatments include physiotherapy, steroid injections, and surgery. Minimally invasive techniques are emerging with the hope that with less postoperative scar tissue formation, there will be less recurrence of the disease. In this chapter, senior author describes his technique for endoscopic sciatic neurolysis.
Autorino, Riccardo; Stein, Robert J; Lima, Estevão; Damiano, Rocco; Khanna, Rakesh; Haber, Georges-Pascal; White, Michael A; Kaouk, Jihad H
2010-05-01
Objective of this study is to provide an evidence-based analysis of the current status and future perspectives of scarless urological surgery. A PubMed search has been performed for all relevant urological literature regarding natural orifice transluminal endoscopic surgery (NOTES) and laparoendoscopic single-site surgery (LESS). In addition, experience with LESS and NOTES at our own institution has been considered. All clinical and investigative reports for LESS and NOTES procedures in the urological literature have been considered. A wide variety of clinical procedures in urology have been successfully completed by using LESS techniques. Thus far, experience with NOTES has largely been investigational, although early clinical reports are emerging. Further development of instrumentation and platforms is necessary for both techniques to become more widely adopted throughout the urological community.
Role of Interventional Radiology in the Emergent Management of Acute Upper Gastrointestinal Bleeding
Navuluri, Rakesh; Patel, Jay; Kang, Lisa
2012-01-01
Approximately 100,000 cases of upper gastrointestinal bleeding (UGIB) require inpatient admission annually in the United States. When medical management and endoscopic therapy are inadequate, endovascular intervention can be lifesaving. These emergent situations highlight the importance of immediate competence of the interventional radiologist in the preangiographic evaluation as well as the endovascular treatment of UGIB. We describe a case of UGIB managed with endovascular embolization and detail the angiographic techniques used. The case description is followed by a detailed discussion of the treatment approach to UGIB, with attention to both nonvariceal and variceal algorithms. PMID:23997408
Robotic transanal endoscopic microsurgery: technical details for the lateral approach.
Buchs, Nicolas C; Pugin, François; Volonte, Francesco; Hagen, Monika E; Morel, Philippe; Ris, Frederic
2013-10-01
Transanal endoscopic microsurgery is a minimally invasive approach reserved for the resection of selected rectal tumors. However, this approach is technically demanding. Although robotic technology may overcome the limitations of this approach, the system can be difficult to dock, especially in the lithotomy position. The study aim is thus to report the technical details of robotic transanal endoscopic microsurgery with the use of a lateral approach. This study is a prospective evaluation of robotic transanal endoscopic microsurgery in a single tertiary institution, under a protocol approved by our local ethics committee. Patients underwent a routine mechanical bowel preparation and were placed in the left or right lateral position according to the tumor location. A circular anal dilatator was used together with the glove port technique. The robotic system was then docked over the hip. A 30° optic and 2 articulated instruments were used with an additional assistant trocar. The tumor excision was realized with an atraumatic grasper and an articulated cautery hook, and the defect was closed with barbed continuous stiches in each case. The primary outcome was the safety and feasibility of the procedure. Three patients underwent a robotic transanal endoscopic microsurgery with the use of the lateral approach. Mean operative time was 110 minutes, including 20 minutes for the docking of the robot. There was 1 intraoperative complication (a pneumoperitoneum without intraabdominal lesion) and no postoperative complications. Mean hospital stay was 3 days. Margins were negative in all the cases. The study was limited by the small number of patients. Robotic transanal endoscopic microsurgery with use of the lateral approach is feasible and may facilitate the local resection of small lesions of the mid and lower rectum. It might assume an important place in sphincter-preserving surgery, especially for selected and early rectal cancer (see Video, Supplemental Digital Content 1, http://links.lww.com/DCR/A114).
Spradling, Kyle; Uribe, Brittany; Okhunov, Zhamshid; Hofmann, Martin; Del Junco, Michael; Hwang, Christina; Gruber, Caden; Youssef, Ramy F; Landman, Jaime
2015-09-01
To evaluate the ignition and burn risk associated with contemporary fiberoptic and distal sensor endoscopic technologies. We used new and used SCB Xenon 300 light sources to illuminate a 4.8 mm fiberoptic cable, 10 mm laparoscope, 5 mm laparoscope, rigid cystoscope, semirigid ureteroscope, flexible cystoscope, flexible fiberoptic ureteroscope, distal sensor cystoscope, and a distal sensor ureteroscope (Karl Storz, Inc., Tuttlingen, Germany). We measured peak temperatures at the distal end of each device. We then evaluated each device on a flat and folded surgical drape to establish ignition risk. Finally, we evaluated the effects of all devices on human cadaver skin covered by surgical drape. Peak temperatures recorded for each device ranged from 26.9°C (flexible fiberoptic ureteroscope) to 194.5°C (fiberoptic cable). Drape ignition was noted when the fiberoptic cable was placed against a fold of drape. Contact with the fiberoptic cable, 10 mm laparoscope, 5 mm laparoscope, and distal sensor cystoscope resulted in cadaver skin damage. Cadaver skin damage occurred despite little or no visible change to the surgical drape. Rigid and flexible fiberoptic cystoscopes and flexible fiberoptic ureteroscopes had no effect on surgical drapes or cadaver skin. Fiberoptic light cables and some endoscopic devices have the potential to cause thermal injury and drape ignition. Thermal injury may occur without visible damage to drapes. Surgeons should remain vigilant regarding the risks associated with these devices and take necessary safety precautions to prevent patient injury.
Silvestri, Michele; Simi, Massimiliano; Cavallotti, Carmela; Vatteroni, Monica; Ferrari, Vincenzo; Freschi, Cinzia; Valdastri, Pietro; Menciassi, Arianna; Dario, Paolo
2011-09-01
In the near future, it is likely that 3-dimensional (3D) surgical endoscopes will replace current 2D imaging systems given the rapid spreading of stereoscopy in the consumer market. In this evaluation study, an emerging technology, the autostereoscopic monitor, is compared with the visualization systems mainly used in laparoscopic surgery: a binocular visor, technically equivalent from the viewer's point of view to the da Vinci 3D console, and a standard 2D monitor. A total of 16 physicians with no experience in 3D interfaces performed 5 different tasks, and the execution time and accuracy of the tasks were evaluated. Moreover, subjective preferences were recorded to qualitatively evaluate the different technologies at the end of each trial. This study demonstrated that the autostereoscopic display is equally effective as the binocular visor for both low- and high-complexity tasks and that it guarantees better performance in terms of execution time than the standard 2D monitor. Moreover, an unconventional task, included to provide the same conditions to the surgeons regardless of their experience, was performed 22% faster when using the autostereoscopic monitor than the binocular visor. However, the final questionnaires demonstrated that 60% of participants preferred the user-friendliness of the binocular visor. These results are greatly heartening because autostereoscopic technology is still in its early stages and offers potential improvement. As a consequence, the authors expect that the increasing interest in autostereoscopy could improve its friendliness in the future and allow the technology to be widely accepted in surgery.
Fluorescence lifetime endoscopy using TCSPC for the measurement of FRET in live cells
Fruhwirth, Gilbert O.; Ameer-Beg, Simon; Cook, Richard; Watson, Timothy; Ng, Tony; Festy, Frederic
2010-01-01
Development of remote imaging for diagnostic purposes has progressed dramatically since endoscopy began in the 1960’s. The recent advent of a clinically licensed intensity-based fluorescence micro-endoscopic instrument has offered the prospect of real-time cellular resolution imaging. However, interrogating protein-protein interactions deep inside living tissue requires precise fluorescence lifetime measurements to derive the Förster resonance energy transfer between two tagged fluorescent markers. We developed a new instrument combining remote fiber endoscopic cellular-resolution imaging with TCSPC-FLIM technology to interrogate and discriminate mixed fluorochrome labeled beads and expressible GFP/TagRFP tags within live cells. Endoscopic-FLIM (e-FLIM) data was validated by comparison with data acquired via conventional FLIM and e-FLIM was found to be accurate for both bright bead and dim live cell samples. The fiber based micro-endoscope allowed remote imaging of 4 µm and 10 µm beads within a thick Matrigel matrix with confident fluorophore discrimination using lifetime information. More importantly, this new technique enabled us to reliably measure protein-protein interactions in live cells embedded in a 3D matrix, as demonstrated by the dimerization of the fluorescent protein-tagged membrane receptor CXCR4. This cell-based application successfully demonstrated the suitability and great potential of this new technique for in vivo pre-clinical biomedical and possibly human clinical applications. PMID:20588974
Fluorescence detection of esophageal neoplasia
NASA Astrophysics Data System (ADS)
Borisova, E.; Vladimirov, B.; Avramov, L.
2008-06-01
White-light endoscopy is well-established and wide used modality. However, despite the many technological advances that have been occurred, conventional endoscopy is suboptimal and usually detects advanced stage lesions. The limitations of standard endoscopy initiate development of spectroscopic techniques, additional to standard endoscopic equipment. One of the most sensitive approaches is fluorescence spectroscopy of gastrointestinal mucosa for neoplasia detection. In the recent study delta-aminolevulinic acid/Protoporphyrin IX (5-ALA/PpIX) is used as fluorescent marker for dysplasia and tumor detection in esophagus. The 5-ALA is administered per os six hours before measurements at dose 20 mg/kg weight. Excitation source has max of emission at 405 nm and light is delivered by the standard light guide of the endoscopic equipment. Through endoscopic instrumental channel a fiber is applied to return information about fluorescence to microspectrometer. Spectral features observed during endoscopic investigations could be distinct as the next regions: 450-630 nm region, where tissue autofluorescence is observed; 630-710 nm region, where fluorescence of PpIX is clearly pronounced; 530-580 nm region, where minima in the autofluorescence signal are observed, related to reabsorption of blood. The lack of fluorescence peaks in the red spectral area for normal mucosa is an indication for selective accumulation of 5-ALA/PpIX only in abnormal sites Very good correlation between fluorescence signals and histology examination of the lesions investigated is achieved.
Minimally invasive multimode optical fiber microendoscope for deep brain fluorescence imaging
Ohayon, Shay; Caravaca-Aguirre, Antonio; Piestun, Rafael; DiCarlo, James J.
2018-01-01
A major open challenge in neuroscience is the ability to measure and perturb neural activity in vivo from well defined neural sub-populations at cellular resolution anywhere in the brain. However, limitations posed by scattering and absorption prohibit non-invasive multi-photon approaches for deep (>2mm) structures, while gradient refractive index (GRIN) endoscopes are relatively thick and can cause significant damage upon insertion. Here, we present a novel micro-endoscope design to image neural activity at arbitrary depths via an ultra-thin multi-mode optical fiber (MMF) probe that has 5–10X thinner diameter than commercially available micro-endoscopes. We demonstrate micron-scale resolution, multi-spectral and volumetric imaging. In contrast to previous approaches, we show that this method has an improved acquisition speed that is sufficient to capture rapid neuronal dynamics in-vivo in rodents expressing a genetically encoded calcium indicator (GCaMP). Our results emphasize the potential of this technology in neuroscience applications and open up possibilities for cellular resolution imaging in previously unreachable brain regions. PMID:29675297
Therapeutic aspects of endoscopic ultrasound
NASA Astrophysics Data System (ADS)
Woodward, Timothy A.
1999-06-01
Endoscopic ultrasound (EUS) is a technology that had been used primarily as a passive imaging modality. Recent advances have enabled us to move beyond the use of EUS solely as a staging tool to an interventional device. Current studies suggest that interventional applications of EUS will allow for minimally invasive assessment and therapies in a cost-effective manner. Endoscopic ultrasound with fine needle aspiration (EUS-FNA) has been demonstrated to be a technically feasible, relatively safe method of obtaining cytologic specimens. The clinical utility of EUS- FNA appears to be greatest in the diagnosis and staging of pancreatic cancer and in the nodal staging of gastrointestinal and pulmonary malignancies. In addition, EUS-FNA has demonstrated utility in the sampling pleural and ascitic fluid not generally appreciated or assessable to standard interventions. Interventional applications of EUS include EUS-guided pseudocyst drainage, EUS-guided injection of botulinum toxin in the treatment of achalasia, and EUS- guided celiac plexus neurolysis in the treatment of pancreatic cancer pain. Finally, EUS-guided fine-needle installation is being evaluated, in conjunction with recent bimolecular treatment modalities, as a delivery system in the treatment of certain gastrointestinal tumors.
Advanced Imaging Technologies for the Detection of Dysplasia and Early Cancer in Barrett Esophagus
Espino, Alberto; Cirocco, Maria; DaCosta, Ralph
2014-01-01
Advanced esophageal adenocarcinomas arising from Barrett esophagus (BE) are tumors with an increasing incidence and poor prognosis. The aim of endoscopic surveillance of BE is to detect dysplasia, particularly high-grade dysplasia and intramucosal cancers that can subsequently be treated endoscopically before progression to invasive cancer with lymph node metastases. Current surveillance practice standards require the collection of random 4-quadrant biopsy specimens over every 1 to 2 cm of BE (Seattle protocol) to detect dysplasia with the assistance of white light endoscopy, in addition to performing targeted biopsies of recognizable lesions. This approach is labor-intensive but should currently be considered state of the art. Chromoendoscopy, virtual chromoendoscopy (e.g., narrow band imaging), and confocal laser endomicroscopy, in addition to high-definition standard endoscopy, might increase the diagnostic yield for the detection of dysplastic lesions. Until these modalities have been demonstrated to enhance efficiency or cost effectiveness, the standard protocol will remain careful examination using conventional off the shelf high-resolution endoscopes, combined with as longer inspection time which is associated with increased detection of dysplasia. PMID:24570883
Endoscopic mucosal resection for early gastric cancer. A case report.
Gheorghe, Cristian; Sporea, Ioan; Becheanu, Gabriel; Gheorghe, Liana
2002-03-01
European experience in endoscopic mucosal resection (EMR) for early gastric cancer is still relatively low, since early stomach cancer is diagnosed at a much lower rate in Europe than in Japan and generally operable patients are referred to surgery for radical resection. Endoscopic mucosal resection or mucosectomy was developed as a promising technology to diagnose and treat mucosal lesions in the esophagus, stomach and colon. In contrast to surgical resection, EMR allows "early cancers" to be removed with a minimal cost, morbidity and mortality. We present the case of a patient with hepatic cirrhosis incidentally diagnosed with an elevated-type IIa early gastric cancer. Echoendoscopy was performed in order to assess the depth of invasion into the gastric wall confirming the only mucosal involvement. We performed an EMR using "cup and suction" method. After the procedure, the patient experienced an acute upper gastrointestinal bleeding from the ulcer bed requiring argon plasma coagulation. The histopathological examination confirmed an early cancer, without involvement of muscularis mucosae. The patient has had an uneventful evolution being well at six months after the procedure
Autonomous locomotion of capsule endoscope in gastrointestinal tract.
Yang, Sungwook; Park, Kitae; Kim, Jinseok; Kim, Tae Song; Cho, Il-Joo; Yoon, Eui-Sung
2011-01-01
Autonomous locomotion in gastrointestinal (GI) tracts is achieved with a paddling-based capsule endoscope. For this, a miniaturized encoder module was developed utilizing a MEMS fabrication technology to monitor the position of paddles. The integrated encoder module yielded the high resolution of 0.0025 mm in the linear motion of the paddles. In addition, a PID control method was implemented on a DSP to control the stroke of the paddles accurately. As a result, the average accuracy and the standard deviation were measured to be 0.037 mm and 0.025 mm by a laser position sensor for the repetitive measurements. The locomotive performance was evaluated via ex-vivo tests according to various strokes in paddling. In an in-vivo experiment with a living pig, the locomotion speed was improved by 58% compared with the previous control method relying on a given timer value for reciprocation of the paddles. Finally, the integrated encoder module and the control system allow consistent paddling during locomotion even under loads in GI tract. It provides the autonomous locomotion without intervention in monitoring and controlling the capsule endoscope.
Varifocal MOEMS fiber scanner for confocal endomicroscopy.
Meinert, Tobias; Weber, Niklas; Zappe, Hans; Seifert, Andreas
2014-12-15
Based on an advanced silicon optical bench technology with integrated MOEMS (Micro-Opto-Electro-Mechanical-System) components, a piezo-driven fiber scanner for confocal microscopy has been developed. This highly-miniaturized technology allows integration into an endoscope with a total outer probe diameter of 2.5 mm. The system features a hydraulically-driven varifocal lens providing axial confocal scanning without any translational movement of components. The demonstrated resolutions are 1.7 μm laterally and 19 μm axially.
Algorithm-Based Motion Magnification for Video Processing in Urological Laparoscopy.
Adams, Fabian; Schoelly, Reto; Schlager, Daniel; Schoenthaler, Martin; Schoeb, Dominik S; Wilhelm, Konrad; Hein, Simon; Wetterauer, Ulrich; Miernik, Arkadiusz
2017-06-01
Minimally invasive surgery is in constant further development and has replaced many conventional operative procedures. If vascular structure movement could be detected during these procedures, it could reduce the risk of vascular injury and conversion to open surgery. The recently proposed motion-amplifying algorithm, Eulerian Video Magnification (EVM), has been shown to substantially enhance minimal object changes in digitally recorded video that is barely perceptible to the human eye. We adapted and examined this technology for use in urological laparoscopy. Video sequences of routine urological laparoscopic interventions were recorded and further processed using spatial decomposition and filtering algorithms. The freely available EVM algorithm was investigated for its usability in real-time processing. In addition, a new image processing technology, the CRS iimotion Motion Magnification (CRSMM) algorithm, was specifically adjusted for endoscopic requirements, applied, and validated by our working group. Using EVM, no significant motion enhancement could be detected without severe impairment of the image resolution, motion, and color presentation. The CRSMM algorithm significantly improved image quality in terms of motion enhancement. In particular, the pulsation of vascular structures could be displayed more accurately than in EVM. Motion magnification image processing technology has the potential for clinical importance as a video optimizing modality in endoscopic and laparoscopic surgery. Barely detectable (micro)movements can be visualized using this noninvasive marker-free method. Despite these optimistic results, the technology requires considerable further technical development and clinical tests.
Huberty, Vincent; Ibrahim, Mostafa; Hiernaux, Martin; Chau, Alexandre; Dugardeyn, Sonia; Devière, Jacques
2017-04-01
Obesity is a major pandemic disease. Surgical therapy is highly effective, but its availability will likely be overwhelmed by the burden of the disease. Endoscopic technologies that could reproduce some of the clinical effects of surgery may become part of the treatment armamentarium. A simple transoral restrictive procedure could play a role in first-line surgical management. We evaluated the safety and feasibility of transmural suturing using a simple triangulation platform for gastric volume reduction through the creation of multiple double plicatures. Between May and July 2015, 11 obese (body mass index 34.6 ± 2.1 kg/m 2 ) patients (mean age, 36 ± 10 years) underwent gastroplasty through transmural endoscopic sutures (performed using a triangulation platform and an endoscopic stitcher). The median duration of the procedure was 2.00 hours (range, 1.15-3.15 hours) and dramatically decreased after the first 5 cases. No severe adverse events were observed. Mean (standard deviation) weight loss and percentage of excess weight loss were 5.8 kg (2.7%) and 21% (9%) at 1 month (n = 11), 8.8 kg (4.9%) and 33% (22%) at 3 months (n = 10), and 10.9 kg (7.3%) and 41% (33%) at 6 months (n = 10). Transoral endoscopic gastroplasty performed using a simple triangulation platform and a dedicated suturing device appears to be safe and effective at mid-term follow-up in creating gastric restriction and inducing weight loss in this first-in-humans experience. (Clinical trials registration number: NCT02534662.). Copyright © 2017 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.
Current role of minimally invasive approaches in the treatment of early gastric cancer
El-Sedfy, Abraham; Brar, Savtaj S; Coburn, Natalie G
2014-01-01
Despite declining incidence, gastric cancer remains one of the most common cancers worldwide. Early detection in population-based screening programs has increased the number of cases of early gastric cancer, representing approximately 50% of newly detected gastric cancer cases in Asian countries. Endoscopic mucosal resection and endoscopic submucosal dissection have become the preferred therapeutic techniques in Japan and Korea for the treatment of early gastric cancer patients with a very low risk of lymph node metastasis. Laparoscopic and robotic resections for early gastric cancer, including function-preserving resections, have propagated through advances in technology and surgeon experience. The aim of this paper is to discuss the recent advances in minimally invasive approaches in the treatment of early gastric cancer. PMID:24833843
Monte Carlo model of light transport in multi-layered tubular organs
NASA Astrophysics Data System (ADS)
Zhang, Yunyao; Zhu, Jingping; Zhang, Ning
2017-02-01
We present a Monte Carlo static light migration model (Endo-MCML) to simulate endoscopic optical spectroscopy for tubular organs such as esophagus and colon. The model employs multi-layered hollow cylinder which emitting and receiving light both from the inner boundary to meet the conditions of endoscopy. Inhomogeneous sphere can be added in tissue layers to model cancer or other abnormal changes. The 3D light distribution and exit angle would be recorded as results. The accuracy of the model has been verified by Multi-layered Monte Carlo(MCML) method and NIRFAST. This model can be used for the forward modeling of light transport during endoscopically diffuse optical spectroscopy, light scattering spectroscopy, reflectance spectroscopy and other static optical detection or imaging technologies.
Ureteroscopy – an essential modern approach in upper urinary tract diagnosis and treatment
Geavlete, P; Jecu, M; Multescu, R; Nita, G; Georgescu, D
2010-01-01
In recent years, urology has seen a real explosion in the development of new technologies. Modern treatment techniques replaced classic therapeutic methods, among which open surgery had an important role. Endourologic therapies led to effective and safe interventions, increased patient comfort and reduced costs. The ‘Saint John’ Emergency Clinical Hospital Department of Urology always intended to align to the new standards of urological treatment including, primarily, minimally invasive techniques, some of them being performed as national premieres. Ureteroscopy is one of them, thus introducing the rigid and semi rigid endoscopes as part of the therapeutic arsenal of our clinic in 1994 and flexible ureteroscopy in 2002. If the targeted pathology was initially limited to stone disease, ureteroscopy currently covers a wide range of affections, being used both for therapeutic but also for diagnostic purposes. Thus, the ureteroscopic approach can diagnose and treat a wide range of upper urinary tract pathologies (lithiasis, tumors, malformations, iatrogenic injuries, etc.). The new technology acquisitions made by our clinic, increased performance, resulting in a complete and fast resolution in many cases, previously implying additional effort from the surgeons. If at first the ureteroscopies' share of daily practice was modest, in recent years it has achieved an extraordinary growth, thus becoming available to both experienced surgeons and young urologists. We believe that our extensive experience in endourological approach is significant and will have a say in the technological developments, which will help both the patients and the practicing urologists. PMID:20968209
Barbagli, Guido; Sansalone, Salvatore; Romano, Giuseppe; Lazzeri, Massimo
2015-03-01
To describe the emergency and delayed treatment of patients with pelvic fracture urethral injuries (PFUI) presenting to an Italian high-volume centre. In a retrospective, observational study we evaluated the spectrum of PFUI and posterior urethroplasty in an Italian high-volume centre, from 1980 to 2013. Patients requiring emergency treatment for PFUI and delayed treatment for pelvic fracture urethral defects (PFUD) were included. Patients with incomplete clinical records were excluded from the study. Descriptive statistical methods were applied. In all, 159 male patients (median age 35 years) were included in the study. A traffic accident was the most frequent (42.8%) cause of PFUI, and accidents at work were reported as the cause of trauma in 34% of patients. Agricultural accidents decreased from 24.4% to 6.2% over the course of the survey. A suprapubic cystostomy was the most frequent (49%) emergency treatment in patients with PFUI. The use of surgical realignment decreased from 31.7% to 6.2%, and endoscopic realignment increased from 9.7% to 35.3%. A bulbo-prostatic anastomosis was the most frequent (62.9%) delayed treatment in patients with PFUD. The use of the Badenoch pull-through decreased from 19.5% to 2.6%, and endoscopic holmium laser urethrotomy increased from 4.9% to 32.7%. The spectrum of PFUI and subsequent treatment of PFUD has changed greatly over the last 10 years at our centre. These changes involved patient age, aetiology, emergency and delayed treatments, and were found to be related to changes in the economy and lifestyle of the Italian patients.
Baracat, Felipe; Moura, Eduardo; Bernardo, Wanderley; Pu, Leonardo Zorron; Mendonça, Ernesto; Moura, Diogo; Baracat, Renato; Ide, Edson
2016-06-01
Peptic ulcer represents the most common cause of upper gastrointestinal bleeding. Endoscopic therapy can reduce the risks of rebleeding, continued bleeding, need for surgery, and mortality. The objective of this review is to compare the different modalities of endoscopic therapy. Studies were identified by searching electronic databases MEDLINE, Embase, Cochrane, LILACS, DARE, and CINAHL. We selected randomized clinical trials that assessed contemporary endoscopic hemostatic techniques. The outcomes evaluated were: initial hemostasis, rebleeding rate, need for surgery, and mortality. The possibility of publication bias was evaluated by funnel plots. An additional analysis was made, including only the higher-quality trials. Twenty-eight trials involving 2988 patients were evaluated. Injection therapy alone was inferior to injection therapy with hemoclip and with thermal coagulation when evaluating rebleeding and the need for emergency surgery. Hemoclip was superior to injection therapy in terms of rebleeding; there were no statistically significant differences between hemoclip alone and hemoclip with injection therapy. There was considerable heterogeneity in the comparisons between hemoclip and thermal coagulation. There were no statistically significant differences between thermal coagulation and injection therapy, though their combination was superior, in terms of rebleeding, to thermal coagulation alone. Injection therapy should not be used alone. Hemoclip is superior to injection therapy, and combining hemoclip with an injectate does not improve hemostatic efficacy above hemoclip alone. Thermal coagulation has similar efficacy as injection therapy; combining these appears to be superior to thermal coagulation alone. Therefore, we recommend the application of hemoclips or the combined use of injection therapy with thermal coagulation for the treatment of peptic ulcer bleeding.
Klebsiella spp. in endoscopy-associated infections: we may only be seeing the tip of the iceberg.
Gastmeier, P; Vonberg, R-P
2014-02-01
Two endoscopy-associated nosocomial outbreaks caused by carbapenemase-producing Klebsiella pneumoniae (CPKP) were recently observed in two German hospitals. In this study, we performed a systematic search of the medical literature in order to elucidate the epidemiology of Klebsiella spp. in endoscopy-associated outbreaks. Medline, the Outbreak Database ( http://www.outbreak-database.com ) and reference lists of articles extracted from these databases were screened for descriptions of endoscopy-associated nosocomial outbreaks. The data extracted and analysed were: (1) the type of medical department affected; (2) characterisation of pathogen to species and conspicuous resistance patterns (if applicable); (3) type of endoscope and the grade of its contamination; (4) number and the types of infections; (5) actual cause of the outbreak. A total of seven nosocomial outbreaks were identified, of which six were outbreaks of endoscopic retrograde cholangiopancreatography-related infections and caused by contaminated duodenoscopes. Including our own outbreaks in the analysis, we identified one extended-spectrum beta-lactamase-producing K. pneumoniae strain and six CPKP strains. Insufficient reprocessing after the use of the endoscope was the main reason for subsequent pathogen transmission. There were only two reports of nosocomial outbreaks due to Klebsiella spp. in the first three decades of endoscopic procedures, but seven additional outbreaks of this kind have been reported within the last 4 years. It is very likely that many of such outbreaks have been missed in the past because this pathogen belongs to the physiological gut flora. However, with the emergence of highly resistant (carbapenemase-producing) strains, strict adherence to infection control guidelines is more important than ever.
ENDOSCOPIC FINDINGS OF UPPER GASTROINTESTINAL BLEEDING IN PATIENTS WITH LIVER CIRROSIS.
Hadayat, Rania; Jehangiri, Attique-ur-Rehman; Gul, Rahid; Khan, Adil Naseer; Said, Khalid; Gandapur, Asadullah
2015-01-01
Acute upper gastrointestinal (GI) bleeding is a common medical emergency. A common risk factor of upper GI bleeding is cirrhosis of liver, which can lead to variceal haemorrhage. 30-40% of cirrhotic patients who bleed may have non-variceal upper GI bleeding and it is frequently caused by peptic ulcers, portal gastropathy, Mallory-Weiss tear, and gastroduodenal erosions. The objective of this study was to determine the frequency of upper gastrointestinal endoscopic findings among patients presenting with upper gastrointestinal bleeding with liver cirrhosis. This descriptive cross-sectional study was carried out in Gastroenterology & Hepatology Department of Ayub Teaching Hospital, Abbottabad from February 2012 to June 2013. 252 patients diagnosed with cirrhosis, presenting with upper GI bleed, age 50 years of either gender, and were included in the study. Non-probability consecutive sampling was used, Endoscopy was performed on each patient and the findings documented. The mean age was 57.84 +/- 6.29 years. There were 158 (62.7%) males and 94 (37.3%) females. The most common endoscopic finding was oesophageal varices (92.9%, n=234) followed by portal hypertensive gastropathy (38.9%, n=98) with almost equal distribution among males and females. Gastric varices were found in 33.3% of patients (n=84). Among other non-variceal lesions, peptic ulcer disease was seen in 26 patients (10.3%) while gastric erosions were found in 8 patients (3.2%). In patients with acute upper GI bleeding and liver cirrhosis, the most common endoscopic finding is oesophageal varices, with a substantially higher value in our part of the country, apart from other non-variceal causes.
Bolzoni Villaret, Andrea; Doglietto, Francesco; Carobbio, Andrea; Schreiber, Alberto; Panni, Camilla; Piantoni, Enrico; Guida, Giovanni; Fontanella, Marco Maria; Nicolai, Piero; Cassinis, Riccardo
2017-09-01
Although robotics has already been applied to several surgical fields, available systems are not designed for endoscopic skull base surgery (ESBS). New conception prototypes have been recently described for ESBS. The aim of this study was to provide a systematic literature review of robotics for ESBS and describe a novel prototype developed at the University of Brescia. PubMed and Scopus databases were searched using a combination of terms, including Robotics OR Robot and Surgery OR Otolaryngology OR Skull Base OR Holder. The retrieved papers were analyzed, recording the following features: interface, tools under robotic control, force feedback, safety systems, setup time, and operative time. A novel hybrid robotic system has been developed and tested in a preclinical setting at the University of Brescia, using an industrial manipulator and readily available off-the-shelf components. A total of 11 robotic prototypes for ESBS were identified. Almost all prototypes present a difficult emergency management as one of the main limits. The Brescia Endoscope Assistant Robotic holder has proven the feasibility of an intuitive robotic movement, using the surgeon's head position: a 6 degree of freedom sensor was used and 2 light sources were added to glasses that were therefore recognized by a commercially available sensor. Robotic system prototypes designed for ESBS and reported in the literature still present significant technical limitations. Hybrid robot assistance has a huge potential and might soon be feasible in ESBS. Copyright © 2017 Elsevier Inc. All rights reserved.
Yamaguchi, Taketo; Ishihara, Takeshi; Seza, Katsutoshi; Nakagawa, Akihiko; Sudo, Kentarou; Tawada, Katsuyuki; Kouzu, Teruo; Saisho, Hiromitsu
2006-01-21
Endoscopic metal stenting (EMS) offers good results in short to medium term follow-up for bile duct stenosis associated with chronic pancreatitis (CP); however, longer follow-up is needed to determine if EMS has the potential to become the treatment of first choice. EMS was performed in eight patients with severe common bile duct stenosis due to CP. After the resolution of cholestasis by endoscopic naso-biliary drainage three patients were subjected to EMS while, the other five underwent EMS following plastic tube stenting. The patients were followed up for more than 5 years through periodical laboratory tests and imaging techniques. EMS was successfully performed in all the patients. Two patients died due to causes unrelated to the procedure: one with an acute myocardial infarction and the other with maxillary carcinoma at 2.8 and 5.5 years after EMS, respectively. One patient died with cholangitis because of EMS clogging 3.6 years after EMS. None of these three patients had showed symptoms of cholestasis during the follow-up period. Two patients developed choledocholithiasis and two suffered from duodenal ulcers due to dislodgement of the stent between 4.8 and 7.3 years after stenting; however, they were successfully treated endoscopically. Thus, five of eight patients are alive at present after a mean follow-up period of 7.4 years. EMS is evidently one of the very promising treatment options for bile duct stenosis associated with CP, provided the patients are closely followed up; thus setting a system for their prompt management on emergency is desirable.
Andreoni, Bruno; Camellini, Lorenzo; Sonzogni, Angelica; Crosta, Cristiano; Pirola, Maria Elena; Corbellini, Carlo
2011-09-01
Colorectal cancer screening programs result in an early diagnosis of the disease. In 2007, 250 malignant polyps were identified in Lombardy, out of 1,329 screen-detected colorectal carcinomas. The Italian Group for Colorectal Cancer (GISCoR) promoted the multicentric study "Endoscopic Follow-up versus Surgical Radicalization of Malignant Polyps after Complete Endoscopic Polypectomy" (SEC-GISCoR). The protocol was a multicentric, prospective, observational, non-randomized study. It included patients diagnosed a colorectal malignant adenoma, after complete endoscopic removal. From November 2005 to September 2009, three participating centers enrolled 120 patients with malignant polyps after "complete" endoscopic polypectomy; malignant polyps were classified as "low risk" or "high risk". The study had two arms: "Intensive follow-up" (42 patients: 32 with low-risk and 10 with high-risk polyps) and "Surgical radicalization" (78 patients: 5 with low-risk and 73 with high-risk polyps). Data were collected using an online CRF. Overall, 37/120 polyps (30.8%) were low risk and 83/120 (69.2%) were high risk. 42 out of 120 patients (35%) were enrolled in the "clinical follow-up" arm, while 78/120 (65%) entered the surgery arm. In 15 cases, patients were not enrolled in the correct arm, according to the criteria agreed upon before starting the study. There still is a high incidence (11.5%) of pathological mismatches. No clinical event was reported in 2.9 years of follow-up. In conclusion, some differences emerged in the management of patients with malignant polyps among participating centers (p < 0.001), mismatches can be explained by high surgical risk or patient's choice. Only in 5 cases (4.2%), did data analysis not allow to exactly determine the reason for a choice different from protocol criteria. The availability of new risk factors and the evidence of pathological mismatches confirmed the need for future studies on this issue.
Chronic Gastric Volvulus with Laparoscopic Gastropexy after Endoscopic Reduction: A Case Report.
Lee, Hye Yeon; Park, Jung Hyun; Kim, Sung Geun
2015-06-01
Gastric volvulus is an uncommon clinical entity. There are three types of gastric volvulus; organoaxial, mesenteroaxial and combined type. This condition can lead to a closed-loop obstruction or strangulation. Traditional surgical therapy for gastric volvulus is based on an open approach. Here we report a successful case of a patient with chronic gastric volvulus with a laparoscopic treatment. A 79-year-old woman came to the emergency department with epigastric pain accompanied by nausea for 2 weeks. Abdominal computed tomography revealed markedly distended stomach with transposition of gastroesophageal Junction and gastric antrum. Barium meal study revealed presence of the antrum was folded over 180 degrees that was located above gastroesophageal junction. We attempted an endoscopic reduction, but it was unsuccessful. The patient got laparoscopic anterior gastropexy. Based on our result, laparoscopic gastropexy can be considered as a good choice of the treatment for gastric volvulus.
DIBRA, A.; KËLLIÇI, S.; ÇELIKU, E.; DRAÇINI, Xh.; MATURO, A.; ÇELIKU, E.
2015-01-01
We present a case of intramural duodenal hematoma as a complication of endoscopic therapy for a bleeding duodenal ulcer in an adult patient with no evidence of other pathologies. A 18-year-old man was admitted in emergency room with gastrointestinal bleeding manifested by melena. Previous medical history revealed that he had endoscopic sclerotherapy for bleeding duodenal ulcer 5 months before. Endoscopy revealed a Forrest 2a ulcer in the duodenal bulb and sclerotherapy was performed by injecting 10 ml of 0.2% epinephrine and 20 ml of NaCl 0.9% solution. Upper occlusion’s signs appeared 36 hours after the procedure. The hematoma, that was identified by endoscopy and confirmed by MRI and CT scan of the abdomen, caused transient duodenal obstruction. Combined conservative management with nasogastric tube and total parenteral nutrition resulted in reduction of obstructive symptoms within 4 weeks. PMID:25827667
Dibra, A; Këlliçi, S; Çeliku, E; Draçini, Xh; Maturo, A; Çeliku, E
2015-01-01
We present a case of intramural duodenal hematoma as a complication of endoscopic therapy for a bleeding duodenal ulcer in an adult patient with no evidence of other pathologies. A 18-year-old man was admitted in emergency room with gastrointestinal bleeding manifested by melena. Previous medical history revealed that he had endoscopic sclerotherapy for bleeding duodenal ulcer 5 months before. Endoscopy revealed a Forrest 2a ulcer in the duodenal bulb and sclerotherapy was performed by injecting 10 ml of 0.2% epinephrine and 20 ml of Na- Cl 0.9% solution. Upper occlusion's signs appeared 36 hours after the procedure. The hematoma, that was identified by endoscopy and confirmed by MRI and CT scan of the abdomen, caused transient duodenal obstruction. Combined conservative management with nasogastric tube and total parenteral nutrition resulted in reduction of obstructive symptoms within 4 weeks.
Foreign bodies and caustic lesions.
Dray, Xavier; Cattan, Pierre
2013-10-01
Foreign body ingestions, food bolus impactions, and caustic agent injuries are frequent but specific situations. Although most foreign bodies will naturally pass through the digestive tract, practitioners should recognize specific situations were endoscopic management is required. In such cases, timing and adequate equipment are critical. Endoscopic treatment is successful in about 95% of patients. Severe complications (including oesophageal perforations) are rare. Underlying diseases (including eosinophilic oesophagitis) must be investigated after food bolus impaction. Accidental or suicidal ingestion of corrosive agents may result in severe upper gastrointestinal tract injuries requiring a multidisciplinary approach including gastroenterologists, surgeons, otorhynolaryngologists, anaesthesiologists and psychiatrists. Treatment includes conservative management of patients with mild injuries, while patients with severe injuries undergo emergency surgical exploration. At distance of the ingestion episode, oesophageal reconstruction is required in patients who underwent oesophageal resection and in patients who developed oesophageal strictures that failed dilatation. Copyright © 2013. Published by Elsevier Ltd.
Role of Endoscopic Gastroplasty Techniques in the Management of Obesity.
Jung, Yunho
2017-01-01
Health and wellness represent a major global concern. Trends such as a lack of exercise and excessive consumption of calories are major causes of the rapid increase in obesity worldwide. Obesity should be controlled because it can result in other illnesses, such as diabetes, high blood pressure, high cholesterol, coronary artery disease, stroke, breathing disorders, or cancer. However, many people have difficulty in managing obesity through exercise, dietary control, behavioral modifications, and drug therapy. Bariatric surgery is not commonly used due to a variety of complications, even though it has been demonstrated to produce reliable results with respect to adequate weight loss when performed using an open or a laparoscopic approach. Endoscopic bariatric procedures are emerging techniques that are less invasive and safer compared with current surgical approaches. However, the evaluation of endoluminal procedures is limited by the small number of studies and their short-term follow-up.
Physiological breakdown of Jeffrey six constant nanofluid flow in an endoscope with nonuniform wall
NASA Astrophysics Data System (ADS)
Nadeem, S.; Shaheen, A.; Hussain, S.
2015-12-01
This paper analyse the endoscopic effects of peristaltic nanofluid flow of Jeffrey six-constant fluid model in the presence of magnetohydrodynamics flow. The current problem is modeled in the cylindrical coordinate system and exact solutions are managed (where possible) under low Reynolds number and long wave length approximation. The influence of emerging parameters on temperature and velocity profile are discussed graphically. The velocity equation is solved analytically by utilizing the homotopy perturbation technique strongly, while the exact solutions are computed from temperature equation. The obtained expressions for velocity , concentration and temperature is sketched during graphs and the collision of assorted parameters is evaluate for transform peristaltic waves. The solution depend on thermophoresis number Nt, local nanoparticles Grashof number Gr, and Brownian motion number Nb. The obtained expressions for the velocity, temperature, and nanoparticles concentration profiles are plotted and the impact of various physical parameters are investigated for different peristaltic waves.
Lober, Robert M.; Doan, Adam T.; Matsumoto, Craig I.; Kenning, Tyler J.; Evans, James J.
2016-01-01
Intraoperative neurophysiological monitoring during endoscopic, endonasal approaches to the skull base is both feasible and safe. Numerous reports have recently emerged from the literature evaluating the efficacy of different neuromonitoring tests during endonasal procedures, making them relatively well-studied. The authors report on a comprehensive, multimodality approach to monitoring the functional integrity of at risk nervous system structures, including the cerebral cortex, brainstem, cranial nerves, corticospinal tract, corticobulbar tract, and the thalamocortical somatosensory system during endonasal surgery of the skull base. The modalities employed include electroencephalography, somatosensory evoked potentials, free-running and electrically triggered electromyography, transcranial electric motor evoked potentials, and auditory evoked potentials. Methodological considerations as well as benefits and limitations are discussed. The authors argue that, while individual modalities have their limitations, multimodality neuromonitoring provides a real-time, comprehensive assessment of nervous system function and allows for safer, more aggressive management of skull base tumors via the endonasal route. PMID:27293965
Fernandez-Nogueras Jimenez, Francisco J; Segura Fernandez-Nogueras, Miguel; Jouma Katati, Majed; Arraez Sanchez, Miguel Ángel; Roda Murillo, Olga; Sánchez Montesinos, Indalecio
2015-01-01
The role of robotic surgery is well established in various specialties such as urology and general surgery, but not in others such as neurosurgery and otolaryngology. In the case of surgery of the skull base, it has just emerged from an experimental phase. To investigate possible applications of the da Vinci surgical robot in transoral skull base surgery, comparing it with the authors' experience using conventional endoscopic transnasal surgery in the same region. A transoral transpalatal approach to the nasopharynx and medial skull base was performed on 4 cryopreserved cadaver heads. We used the da Vinci robot, a 30° standard endoscope 12mm thick, dual camera and dual illumination, Maryland forceps on the left terminal and curved scissors on the right, both 8mm thick. Bone drilling was performed manually. For the anatomical study of this region, we used 0.5cm axial slices from a plastinated cadaver head. Various skull base structures at different depths were reached with relative ease with the robot terminals Transoral robotic surgery with the da Vinci system provides potential advantages over conventional endoscopic transnasal surgery in the surgical approach to this region. Copyright © 2014 Sociedad Española de Neurocirugía. Published by Elsevier España. All rights reserved.
A videoscope for use in minimally invasive periodontal surgery.
Harrel, Stephen K; Wilson, Thomas G; Rivera-Hidalgo, Francisco
2013-09-01
Minimally invasive periodontal procedures have been reported to produce excellent clinical results. Visualization during minimally invasive procedures has traditionally been obtained by the use of surgical telescopes, surgical microscopes, glass fibre endoscopes or a combination of these devices. All of these methods for visualization are less than fully satisfactory due to problems with access, magnification and blurred imaging. A videoscope for use with minimally invasive periodontal procedures has been developed to overcome some of the difficulties that exist with current visualization approaches. This videoscope incorporates a gas shielding technology that eliminates the problems of fogging and fouling of the optics of the videoscope that has previously prevented the successful application of endoscopic visualization to periodontal surgery. In addition, as part of the gas shielding technology the videoscope also includes a moveable retractor specifically adapted for minimally invasive surgery. The clinical use of the videoscope during minimally invasive periodontal surgery is demonstrated and discussed. The videoscope with gas shielding alleviates many of the difficulties associated with visualization during minimally invasive periodontal surgery. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Ultrasonography of the pancreas. 6. Endoscopic imaging.
Chaya, C T; Bhutani, M S
2007-01-01
EUS is a high-resolution technique for pancreatic imaging. EUS has applictions in detecting and staging pancreatic tumors, EUS guided FNA of the pancreas for tissue diagnosis, and evaluation of chronic pancreatitis as well as EUS guided therapy such as celiac plexus block. This is a review of EUS imaging (EUS) of the pancreas covering technical aspects, clinical indications, advantages, and pitfalls as well as emerging trends in the field.
Skull base erosion and associated complications in sphenoid sinus fungal balls
Meier, Josh C.; Remenschneider, Aaron K.; Sadow, Peter; Chambers, Kyle; Dedmon, Matt; Lin, Derrick T.; Holbrook, Eric H.; Metson, Ralph; Gray, Stacey T.
2016-01-01
Background: Sphenoid sinus fungal balls (SSFB) are rare entities that can result in serious orbital and intracranial complications. There are few published reports of complications that result from SSFB. Objective: To review the incidence of skull base erosion and orbital or intracranial complications in patients who present with SSFB. Methods: A retrospective review was performed of all the patients with SSFB who were treated at the Massachusetts Eye and Ear Infirmary from 2006 to 2014. Presenting clinical data, radiology, operative reports, pathology, and postoperative course were reviewed. Results: Forty-three patients with SSFB were identified. Demographic data were compared between patients with (39.5%) and those without (61.5%) skull base erosion. Two patients underwent emergent surgery for acute complications of SSFB (one patient with blindness, one patient who had a seizure). Both patients with acute complications had evidence of skull base erosion, whereas no patients with an intact skull base developed an orbital or intracranial complication (p = 0.15). All the patients were surgically managed via an endoscopic approach. Conclusion: SSFBs are rare but may cause significant skull base erosion and potentially severe orbital and intracranial complications if not treated appropriately. Endoscopic sphenoidotomy is effective in treating SSFB and should be performed emergently in patients who presented with associated complications. PMID:28683250
Caronna, Roberto; Bezzi, Mario; Schiratti, Monica; Cardi, Maurizio; Prezioso, Giampaolo; Benedetti, Michele; Papini, Federica; Mangioni, Simona; Martino, Gabriele; Chirletti, Piero
2008-01-01
A non cirrhotic patient with esophageal varices and portal vein thrombosis had recurrent variceal bleeding unsuccessfully controlled by endoscopy and esophageal transection. Emergency transhepatic portography confirmed the thrombosed right branch of the portal vein, while the left branch appeared angulated, shifted and stenotic. A stent was successfully implanted into the left branch and the collateral vessels along the epatoduodenal ligament disappeared. In patients with esophageal variceal hemorrhage and portal thrombosis if endoscopy fails, emergency esophageal transection or nonselective portocaval shunting are indicated. The rare patients with only partial portal thrombosis can be treated directly with stenting through an angioradiologic approach. PMID:18644135
Design of embedded endoscopic ultrasonic imaging system
NASA Astrophysics Data System (ADS)
Li, Ming; Zhou, Hao; Wen, Shijie; Chen, Xiodong; Yu, Daoyin
2008-12-01
Endoscopic ultrasonic imaging system is an important component in the endoscopic ultrasonography system (EUS). Through the ultrasonic probe, the characteristics of the fault histology features of digestive organs is detected by EUS, and then received by the reception circuit which making up of amplifying, gain compensation, filtering and A/D converter circuit, in the form of ultrasonic echo. Endoscopic ultrasonic imaging system is the back-end processing system of the EUS, with the function of receiving digital ultrasonic echo modulated by the digestive tract wall from the reception circuit, acquiring and showing the fault histology features in the form of image and characteristic data after digital signal processing, such as demodulation, etc. Traditional endoscopic ultrasonic imaging systems are mainly based on image acquisition and processing chips, which connecting to personal computer with USB2.0 circuit, with the faults of expensive, complicated structure, poor portability, and difficult to popularize. To against the shortcomings above, this paper presents the methods of digital signal acquisition and processing specially based on embedded technology with the core hardware structure of ARM and FPGA for substituting the traditional design with USB2.0 and personal computer. With built-in FIFO and dual-buffer, FPGA implement the ping-pong operation of data storage, simultaneously transferring the image data into ARM through the EBI bus by DMA function, which is controlled by ARM to carry out the purpose of high-speed transmission. The ARM system is being chosen to implement the responsibility of image display every time DMA transmission over and actualizing system control with the drivers and applications running on the embedded operating system Windows CE, which could provide a stable, safe and reliable running platform for the embedded device software. Profiting from the excellent graphical user interface (GUI) and good performance of Windows CE, we can not only clearly show 511×511 pixels ultrasonic echo images through application program, but also provide a simple and friendly operating interface with mouse and touch screen which is more convenient than the traditional endoscopic ultrasonic imaging system. Including core and peripheral circuits of FPGA and ARM, power network circuit and LCD display circuit, we designed the whole embedded system, achieving the desired purpose by implementing ultrasonic image display properly after the experimental verification, solving the problem of hugeness and complexity of the traditional endoscopic ultrasonic imaging system.
Surgical navigation in urology: European perspective.
Rassweiler, Jens; Rassweiler, Marie-Claire; Müller, Michael; Kenngott, Hannes; Meinzer, Hans-Peter; Teber, Dogu
2014-01-01
Use of virtual reality to navigate open and endoscopic surgery has significantly evolved during the last decade. Current status of seven most interesting projects inside the European Association of Urology section of uro-technology is summarized with review of literature. Marker-based endoscopic tracking during laparoscopic radical prostatectomy using high-definition technology reduces positive margins. Marker-based endoscopic tracking during laparoscopic partial nephrectomy by mechanical overlay of three-dimensional-segmented virtual anatomy is helpful during planning of trocar placement and dissection of renal hilum. Marker-based, iPAD-assisted puncture of renal collecting system shows more benefit for trainees with reduction of radiation exposure. Three-dimensional laser-assisted puncture of renal collecting system using Uro-Dyna-CT realized in an ex-vivo model enables minimal radiation time. Electromagnetic tracking for puncture of renal collecting system using a sensor at the tip of ureteral catheter worked in an in-vivo model of porcine ureter and kidney. Attitude tracking for ultrasound-guided puncture of renal tumours by accelerometer reduces the puncture error from 4.7 to 1.8 mm. Feasibility of electromagnetic and optical tracking with the da Vinci telemanipulator was shown in vitro as well as using in-vivo model of oesophagectomy. Target registration error was 11.2 mm because of soft-tissue deformation. Intraoperative navigation is helpful during percutaneous puncture collecting system and biopsy of renal tumour using various tracking techniques. Early clinical studies demonstrate advantages of marker-based navigation during laparoscopic radical prostatectomy and partial nephrectomy. Combination of different tracking techniques may further improve this interesting addition to video-assisted surgery.
History of endonasal skull base surgery.
Wang, Amy J; Zaidi, Hasan A; Laws, Edward D
2016-12-01
While the endonasal approach to the skull base continues to advance, this paper invokes its long history. The centuries of medieval neuroanatomy and early neurosurgery enabled the conception of the first transfacial approaches in the late 1800s; Henry Schloffer performed the first transsphenoidal surgery in 1907. Although the procedure was initially met with much interest, Harvey Cushing eventually led the field of neurosurgery to abandon the transsphenoidal approach in the 1920s. The following three generations of neurosurgeons contained several key figures including Norman Dott, Gerard Guiot, and Jules Hardy who were steadfast in preserving the technique as well as in addressing its shortcomings. The endoscopic approach developed simultaneously, and advances in magnifying and fiberoptics further resolved limitations previously inherent to the transsphenoidal approach. At last, in the 1960s, the transsphenoidal approach entered its renaissance. Today, the momentum of its development persists in the endoscopic endonasal approach, which has recently expanded the indications for transsphenoidal surgery across the skull base, far beyond its original jurisdiction of the sella. Continued progress must not take for granted the rich history of the transsphenoidal approach, which was developed over centuries by surgeons around the world. The authors present the evolution of modern endonasal surgery as a dynamic interplay between technology, medicine, and surgery over the past 100 years. Progress can be attributed to courageous surgeons who affirmed their contemporary practices despite gaps in technology or medicine, and to visionary individuals who produced and incorporated new elements into transsphenoidal surgery. And so while the new endoscopic technique brings forth new challenges, its development reaffirms the principles laid down by the pioneers of transsphenoidal surgery.
21 CFR 876.1500 - Endoscope and accessories.
Code of Federal Regulations, 2013 CFR
2013-04-01
... within this generic type of device include cleaning accessories for endoscopes, photographic accessories for endoscopes, nonpowered anoscopes, binolcular attachments for endoscopes, pocket battery boxes... endoscope, smoke removal tube, rechargeable battery box, pocket battery box, bite block for endoscope, and...
21 CFR 876.1500 - Endoscope and accessories.
Code of Federal Regulations, 2011 CFR
2011-04-01
... within this generic type of device include cleaning accessories for endoscopes, photographic accessories for endoscopes, nonpowered anoscopes, binolcular attachments for endoscopes, pocket battery boxes... endoscope, smoke removal tube, rechargeable battery box, pocket battery box, bite block for endoscope, and...
21 CFR 876.1500 - Endoscope and accessories.
Code of Federal Regulations, 2012 CFR
2012-04-01
... within this generic type of device include cleaning accessories for endoscopes, photographic accessories for endoscopes, nonpowered anoscopes, binolcular attachments for endoscopes, pocket battery boxes... endoscope, smoke removal tube, rechargeable battery box, pocket battery box, bite block for endoscope, and...
21 CFR 876.1500 - Endoscope and accessories.
Code of Federal Regulations, 2010 CFR
2010-04-01
... within this generic type of device include cleaning accessories for endoscopes, photographic accessories for endoscopes, nonpowered anoscopes, binolcular attachments for endoscopes, pocket battery boxes... endoscope, smoke removal tube, rechargeable battery box, pocket battery box, bite block for endoscope, and...
21 CFR 876.1500 - Endoscope and accessories.
Code of Federal Regulations, 2014 CFR
2014-04-01
... within this generic type of device include cleaning accessories for endoscopes, photographic accessories for endoscopes, nonpowered anoscopes, binolcular attachments for endoscopes, pocket battery boxes... endoscope, smoke removal tube, rechargeable battery box, pocket battery box, bite block for endoscope, and...
Early endoscopic ultrasonography in acute biliary pancreatitis: A prospective pilot study
Anderloni, Andrea; Galeazzi, Marianna; Ballarè, Marco; Pagliarulo, Michela; Orsello, Marco; Del Piano, Mario; Repici, Alessandro
2015-01-01
AIM: To investigate the clinical usefulness of early endoscopic ultrasonography (EUS) in the management of acute biliary pancreatitis (ABP). METHODS: All consecutive patients entering the emergency department between January 2010 and December 2012 due to acute abdominal pain and showing biochemical and/or radiological findings consistent with possible ABP were prospectively enrolled. Patients were classified as having a low, moderate, or high probability of common bile duct (CBD) stones, according to the established risk stratification. Exclusion criteria were: gastrectomy or patient in whom the cause of biliary obstruction was already identified by ultrasonography. All enrolled patients underwent EUS within 48 h of their admission. Endoscopic retrograde cholangiopancreatography was performed immediately after EUS only in those cases with proven CBD stones or sludge. The following parameters were investigated: (1) clinical: age, sex, fever; (2) radiological: dilated CBD; and (3) biochemical: bilirubin, AST, ALT, gGT, ALP, amylase, lipasis, PCR. Association between presence of CBD stone at EUS and the individual predictors were assessed by univariate logistic regression. Predictors significantly associated with CBD stones (P < 0.05) were entered in a multivariate logistic regression model. RESULTS: A total of 181 patients with pancreatitis were admitted to the emergency department between January 2010 and December 2012. After exclusion criteria a total of 71 patients (38 females, 53.5%, mean age 58 ± 20.12 years, range 27-89 years; 33 males, 46.5%, mean age 65 ± 11.86 years, range 41-91 years) were included in the present study. The probability of CBD stones was considered low in 21 cases (29%), moderate in 26 (37%), and high in the remaining 24 (34%). The 71 patients included in the study underwent EUS, which allowed for a complete evaluation of the target sites in all the cases. The procedure was completed in a mean time of 14.7 min (range 9-34 min), without any notable complications.The overall CBD stone frequency was 44% (31 of 71), with a significant increase from the group at low pretest probability to that at moderate (OR = 5.79, P = 0.01) and high (OR = 4.25, P = 0.03) pretest probability. CONCLUSION: Early EUS in ABP allows, if appropriate, immediate endoscopic treatment and significant spare of unnecessary operative procedures thus reducing possible related complications. PMID:26420969
Surgical evaluation of a novel tethered robotic capsule endoscope using micro-patterned treads.
Sliker, Levin J; Kern, Madalyn D; Schoen, Jonathan A; Rentschler, Mark E
2012-10-01
The state-of-the-art technology for gastrointestinal (GI) tract exploration is a capsule endoscope (CE). Capsule endoscopes are pill-sized devices that provide visual feedback of the GI tract as they move passively through the patient. These passive devices could benefit from a mobility system enabling maneuverability and controllability. Potential benefits of a tethered robotic capsule endoscope (tRCE) include faster travel speeds, reaction force generation for biopsy, and decreased capsule retention. In this work, a tethered CE is developed with an active locomotion system for mobility within a collapsed lumen. Micro-patterned polydimethylsiloxane (PDMS) treads are implemented onto a custom capsule housing as a mobility method. The tRCE housing contains a direct current (DC) motor and gear train to drive the treads, a video camera for visual feedback, and two light sources (infrared and visible) for illumination. The device was placed within the insufflated abdomen of a live anesthetized pig to evaluate mobility performance on a planar tissue surface, as well as within the cecum to evaluate mobility performance in a collapsed lumen. The tRCE was capable of forward and reverse mobility for both planar and collapsed lumen tissue environments. Also, using an onboard visual system, the tRCE was capable of demonstrating visual feedback within an insufflated, anesthetized porcine abdomen. Proof-of-concept in vivo tRCE mobility using micro-patterned PDMS treads was shown. This suggests that a similar method could be implemented in future smaller, faster, and untethered RCEs.
Dynamic focus-tracking MEMS scanning micromirror with low actuation voltages for endoscopic imaging.
Strathman, Matthew; Liu, Yunbo; Li, Xingde; Lin, Lih Y
2013-10-07
We demonstrate a 3-D scanning micromirror device that combines 2-D beam scanning with focus control in the same device using micro-electro-mechanical-systems (MEMS) technology. 2-D beam scanning is achieved with a biaxial gimbal structure and focus control is obtained with a deformable mirror membrane surface. The micromirror with 800 micrometer diameter is designed to be sufficiently compact and efficient so that it can be incorporated into an endoscopic imaging probe in the future. The design, fabrication and characterization of the device are described in this paper. Using the focus-tracking MEMS scanning mirror, we achieved an optical scanning range of >16 degrees with <40 V actuation voltage at resonance and a tunable focal length between infinity and 25 mm with <100V applied bias.
Orloff, Marshall J
2014-02-01
Emergency treatment of bleeding esophageal varices (BEV) consists mainly of endoscopic and pharmacologic measures, with transjugular intrahepatic portal-systemic shunt (TIPS) performed when bleeding is not controlled. Surgical shunt has been relegated to salvage. At the University of California, San Diego, Medical Center, our group has conducted 10 studies of emergency portacaval shunt (EPCS) during 46 years. To describe 2 randomized clinical trials (RCTs) conducted from 1988 to 2011 in unselected consecutive patients who received emergency treatment for BEV. In RCT No. 1, a total of 211 unselected consecutive patients with cirrhosis and acute BEV were randomized to emergency endoscopic sclerotherapy (EEST) (n=106) or EPCS (n=105). In RCT No. 2, a total of 154 unselected consecutive patients with cirrhosis and acute BEV were randomized to TIPS (n=78) or EPCS (n=76). Diagnostic workup was completed within 6 hours of initial contact, and primary treatment was initiated within 8 to 12 hours. Regular follow-up for up to 10 years was accomplished in 100% of the patients. In RCT No. 1, EEST or EPCS; in RCT No. 2, TIPS or EPCS. The 2 groups were compared with regard to survival, control of bleeding, portal-systemic encephalopathy, and direct cost of care. RESULTS Distribution in Child risk classes was almost identical. One-third of patients were in Child class C. Permanent control of bleeding was achieved by EEST in only 20% of the patients and by TIPS in only 22%. In contrast, EPCS permanently controlled bleeding in 97% and 100% of the patients in RCT No. 2 and RCT No. 1, respectively (P<.001). Survival was significantly greater following EPCS than after EEST and TIPS (P<.001). Median survival was more than 10 years following EPCS compared with 1.99 years after TIPS. Occlusion of TIPS was demonstrated in 84% of the patients, 63% of whom underwent TIPS revision, which failed in 80% of the cases. Recurrent portal-systemic encephalopathy developed in 35% of the patients who underwent EEST and 61% of those who received TIPS. In contrast, portal-systemic encephalopathy occurred in 15% of the patients who received EPCS in RCT No. 1 and 21% of those in RCT No. 2. Direct costs of care were 5 to 7 times greater in the EEST ($168100) and TIPS ($264800) groups than in the EPCS ($39000) group (P<.001). Emergency portacaval shunt permanently stopped variceal bleeding, almost never became occluded, accomplished 5 times the long-term survival than EEST or TIPS, and was much less costly than EEST or TIPS. The widespread practice of using EPCS mainly as salvage for failure of endoscopic therapy or TIPS is not supported by the definitive results of these long-term RCTs in unselected patients with cirrhosis. TRIAL REGISTRATION clinicaltrials.gov Identifier: NCT00690027 and NCT00734227.
Clinical research for delayed hemorrhage after endoscopic sphincterotomy
Wang, Yundong; Han, Zhen; Niu, Xiaoping; Jia, Yuliang; Yuan, Heming; Zhang, Guozheng; He, Chiyi
2015-01-01
To analyze the effect of delayed hemorrhage after endoscopic sphincterotomy (EST) and compare the efficacy in improving complication between medicine treatment alone and medicine combined with endoscopic treatment. 1741 patients with EST admitted in Yijishan hospital of Wannan medical college from September 2009 to May 2014 were enrolled in this study. 32 cases suffered from delayed hemorrhage. The patients with delayed hemorrhage were evaluated through incision length of duodenal papilla, clinical manifestation, stool occult blood test and the difference of hemoglobin concentration between pre and post operation. 32 patients were divided into mild bleeding group, mild serious group and serious group through the speed and amount of bleeding. All cases in mild group accepted medicine treatment. Mild serious group were divided into medicine therapy group and medicine combined with endoscopic therapy group randomly. Serious group accepted vascular intervention therapy even traditional operation. The different treatments for delayed hemorrhage were judged by efficiency. The dates were analyzed by t-test or chi-square test. Nobody endured delayed hemorrhage who accepted small incision. Delayed hemorrhage was found in 7 patients out of 627 cases who accepted medium-large incision, 25 patients of 920 cases who accepted large incision. The patients who accepted lager EST were more dangerous than small EST (χ2=4.718, P=0.030) concerning delayed hemorrhage. 32 cases in 1741 patients suffered from delayed hemorrhage. 14 patients only have passed black stool after EST. Among 14 cases, 13 patients stop bleeding after medical therapy, and 1 case received endoscopic hemostasis. 15 cases with hematemesis or melena after EST, 7 patients who received combination therapy stop bleeding. 3 patients from 8 cases stop bleeding after single chemical treatment, 5 cases had to receive endoscopic hemostasis after ineffectual medical therapy. There are significant difference for concerning effect between combination therapy group and medical therapy group (P=0.026). 3 patients repeatedly vomited blood and develop to peripheral circulatory failure. Those patients all received vascular intervention therapy, 2 patients stop bleeding, 1 patient failed in vascular intervention therapy and given up emergency rescue and died. Large EST has more risks than small EST in concerning delayed hemorrhage. Delayed bleeding after EST should be treated by different levels. Adapted therapy should be recommend for patients with different levels bleeding. PMID:26131161
Statham, Melissa McCarty; Willging, J Paul
2010-10-01
Guidelines issued by the Association of Operating Room Nurses and the Association of Professionals in Infection Control and Epidemiology recommend high-level disinfection (HLD) for semicritical instruments, such as flexible endoscopes. We aim to examine the durability of endoscopes to continued use and automated HLD. We report the number of duty cycles a flexible endoscope can withstand before repairs should be anticipated. Retrospective review. A total of 4,336 endoscopic exams and subsequent disinfection cycles were performed with 60 flexible endoscopes in an outpatient tertiary pediatric otolaryngology practice from 2005 to 2009. All endoscopes were systemically cleaned with mechanical cleansing followed by leak testing, enzymatic cleaning, and exposure to Orthophthaldehyde (0.55%) for 5 minutes at a temperature of at least 25°C, followed by rinsing for 3 minutes. A total of 77 repairs were performed, 48 major (average cost $3,815.97), and 29 minor (average cost $326.85). On average, the 2.2-mm flexible endoscopes were utilized for 61.9 examinations before major repair was needed, whereas the 3.6 mm endoscopes were utilized for 154.5 exams before needing minor repairs. No major repairs have been needed to date on the 3.6-mm endoscopes. Automated endoscope reprocessor use for HLD is an effective means to disinfect and process flexible endoscopes. This minimizes variability in the processing of the endoscopes and maximizes the rate of successful HLD. Even when utilizing standardized, automated HLD and limiting the number of personnel processing the endoscopes, smaller fiberoptic endoscopes demonstrate a shortened time interval between repairs than that seen with the larger endoscopes. Laryngoscope, 2010.
Endoluminal full-thickness plication and radiofrequency treatments for GERD: an outcomes comparison.
Jeansonne, Louis O; White, Brent C; Nguyen, Vien; Jafri, Syed M; Swafford, Vickie; Katchooi, Mina; Khaitan, Leena; Davis, S Scott; Smith, C Daniel; Sedghi, Shahriar; Lin, Edward
2009-01-01
Endoluminal therapies have emerged as adjuncts for the treatment of gastroesophageal reflux disease (GERD) in select patients. To compare the effectiveness of endoscopic full-thickness plication and endoscopic radiofrequency treatments for patients with GERD. A total of 126 patients who underwent either endoscopic full-thickness plication (FTP) of the gastric cardia or endoscopic radiofrequency (RF) treatment of the esophagogastric junction during a 4-year period were included (68 underwent RF and 58 underwent FTP). Follow-up data was obtained for 51% of patients (mean follow-up, 6 months). Comparison of medication use, symptom scores, and pH values at baseline and follow-up. In the RF group, patients with moderate to severe heartburn decreased from 55% to 22% (P < .01), and proton pump inhibitor (PPI) use decreased from 84% to 50% (P = .01). Decreases were also seen for dysphagia, voice symptoms, and cough. Percentage of time the pH was less than 4 was unchanged. In the FTP group, patients with moderate to severe heartburn decreased from 53% to 43% (P = .3), and PPI use decreased from 95% to 43% (P = .01). Percentage of time the pH was less than 4 decreased from 10.0% to 6.1% (P = .05). Decreases were also seen for regurgitation, voice symptoms, and dysphagia. There was no change in scores for chest pain or asthma in either group. For patients with GERD, RF and FTP both resulted in a decrease in both PPI use and in scores for voice symptoms and dysphagia. In addition, RF resulted in decreased heartburn and cough, while FTP resulted in the most dramatic reduction in regurgitation. Our experience indicates that both procedures are effective, providing symptomatic relief and reduction in PPI use. For patients whose chief complaint is regurgitation, FTP may be the preferred procedure.
Mahajan, Pranav; Chandail, Vijant Singh
2017-01-01
Upper gastrointestinal (GI) bleeding is a common medical emergency associated with significant morbidity and mortality. The clinical presentation depends on the amount and location of hemorrhage and the endoscopic profile varies according to different etiology. At present, there are limited epidemiological data on upper GI bleed and associated mortality from India, especially in the middle and elderly age group, which has a higher incidence and mortality from this disease. This study aims to study the clinical and endoscopic profile of middle aged and elderly patients suffering from upper GI bleed to know the etiology of the disease and outcome of the intervention. Out of a total of 1790 patients who presented to the hospital from May 2015 to August 2017 with upper GI bleed, and underwent upper GI endoscopy, data of 1270 patients, aged 40 years and above, was compiled and analyzed retrospectively. All the patients included in the study were above 40 years of age. Majority of the patients were males, with a male to female ratio of 1.6:1. The most common causes of upper GI bleed in these patients were portal hypertension-related (esophageal, gastric and duodenal varices, portal hypertensive gastropathy, and gastric antral vascular ectasia GAVE), seen in 53.62% of patients, followed by peptic ulcer disease (gastric and duodenal ulcers) seen in 17.56% of patients. Gastric erosions/gastritis accounted for 15.20%, and duodenal erosions were seen in 5.8% of upper GI bleeds. The in-hospital mortality rate in our study population was 5.83%. The present study reported portal hypertension as the most common cause of upper GI bleeding, while the most common endoscopic lesions reported were esophageal varices, followed by gastric erosion/gastritis, and duodenal ulcer.
Medical-grade Sterilizable Target for Fluid-immersed Fetoscope Optical Distortion Calibration.
Nikitichev, Daniil I; Shakir, Dzhoshkun I; Chadebecq, François; Tella, Marcel; Deprest, Jan; Stoyanov, Danail; Ourselin, Sébastien; Vercauteren, Tom
2017-02-23
We have developed a calibration target for use with fluid-immersed endoscopes within the context of the GIFT-Surg (Guided Instrumentation for Fetal Therapy and Surgery) project. One of the aims of this project is to engineer novel, real-time image processing methods for intra-operative use in the treatment of congenital birth defects, such as spina bifida and the twin-to-twin transfusion syndrome. The developed target allows for the sterility-preserving optical distortion calibration of endoscopes within a few minutes. Good optical distortion calibration and compensation are important for mitigating undesirable effects like radial distortions, which not only hamper accurate imaging using existing endoscopic technology during fetal surgery, but also make acquired images less suitable for potentially very useful image computing applications, like real-time mosaicing. In this paper proposes a novel fabrication method to create an affordable, sterilizable calibration target suitable for use in a clinical setup. This method involves etching a calibration pattern by laser cutting a sandblasted stainless steel sheet. This target was validated using the camera calibration module provided by OpenCV, a state-of-the-art software library popular in the computer vision community.
[Evolution of maxillary sinus surgery in a university hospital].
Waizel-Haiat, Salomón; Solano-Mendoza, María del Carmen; Vargas-Aguayo, Alejandro Martin
2012-01-01
Maxillary sinus surgery has been evolving and, due to advances in technology, endoscopic surgery is widely used in the maxillary sinus for multiple pathologies that 15 years ago were treated through open approaches. For this reason, we conducted an observational descriptive study. We reviewed the clinical records of patients with pathology involving the maxillary sinus and who were surgically treated from January 2008 to December 2009, type of disease, surgical approach used, presence of complications, pre- and postoperative score according to the Lund-Mackay scale, and resolution (or not) of symptoms. We compared these results with a previous study carried out in 1994 in our hospital. We found a total of 177 patients with maxillary sinus-related pathology, of whom 46 patients were excluded. In 131 patients we found a clear predominance of chronic rhinosinusitis without polyps as a pre-surgical diagnosis. We used four different approaches: endoscopic (88.5%), combined approach (5.5%), sublabial expanded (4.5%) and Caldwell Luc (1.5%); 41% of the patients received 0 points on the postoperative Lund-Mackay scale. Surgery of the maxillary sinus in our hospital has evolved considerably; the endoscopic approach was used as a surgical treatment in >90% of patients with a low percentage of complications.
[Digital imaging and robotics in endoscopic surgery].
Go, P M
1998-05-23
The introduction of endoscopical surgery has among other things influenced technical developments in surgery. Owing to digitalisation, major progress will be made in imaging and in the sophisticated technology sometimes called robotics. Digital storage makes the results of imaging diagnostics (e.g. the results of radiological examination) suitable for transmission via video conference systems for telediagnostic purposes. The availability of digital video technique renders possible the processing, storage and retrieval of moving images as well. During endoscopical operations use may be made of a robot arm which replaces the camera man. The arm does not grow tired and provides a stable image. The surgeon himself can operate or address the arm and it can remember fixed image positions to which it can return if ordered to do so. The next step is to carry out surgical manipulations via a robot arm. This may make operations more patient-friendly. A robot arm can also have remote control: telerobotics. At the Internet site of this journal a number of supplements to this article can be found, for instance three-dimensional (3D) illustrations (which is the purpose of the 3D spectacles enclosed with this issue) and a quiz (http:@appendix.niwi. knaw.nl).
Jones, J A; Johnston, S; Campbell, M; Miles, B; Billica, R
1999-05-01
The risk of a urinary calculus during an extended duration mission into the reduced gravity environment of space is significant. For medical operations to develop a comprehensive strategy for the spaceflight stone risk, both preventive countermeasures and contingency management (CM) plans must be included. A feasibility study was conducted to demonstrate the potential CM technique of endoscopic ureteral stenting with ultrasound guidance for the possible in-flight urinary calculus contingency. The procedure employed the International Space Station/Human Research Facility ultrasound unit for guide wire and stent localization, a flexible cystoscope for visual guidance, and banded, biocompatible soft ureteral stents to successfully stent porcine ureters bilaterally in zero gravity (0g). The study demonstrated that downlinked endoscopic surgical and ultrasound images obtained in 0g are comparable in quality to 1g images, and therefore are useful for diagnostic clinical utility via telemedicine transmission. In order to be successful, surgical procedures in 0g require excellent positional stability of the operating surgeon, assistant, and patient, relative to one another. The technological development of medical procedures for long-duration spaceflight contingencies may lead to improved terrestrial patient care methodology and subsequently reduced morbidity.
NASA Technical Reports Server (NTRS)
Jones, J. A.; Johnston, S.; Campbell, M.; Miles, B.; Billica, R.
1999-01-01
OBJECTIVES: The risk of a urinary calculus during an extended duration mission into the reduced gravity environment of space is significant. For medical operations to develop a comprehensive strategy for the spaceflight stone risk, both preventive countermeasures and contingency management (CM) plans must be included. METHODS: A feasibility study was conducted to demonstrate the potential CM technique of endoscopic ureteral stenting with ultrasound guidance for the possible in-flight urinary calculus contingency. The procedure employed the International Space Station/Human Research Facility ultrasound unit for guide wire and stent localization, a flexible cystoscope for visual guidance, and banded, biocompatible soft ureteral stents to successfully stent porcine ureters bilaterally in zero gravity (0g). RESULTS: The study demonstrated that downlinked endoscopic surgical and ultrasound images obtained in 0g are comparable in quality to 1g images, and therefore are useful for diagnostic clinical utility via telemedicine transmission. CONCLUSIONS: In order to be successful, surgical procedures in 0g require excellent positional stability of the operating surgeon, assistant, and patient, relative to one another. The technological development of medical procedures for long-duration spaceflight contingencies may lead to improved terrestrial patient care methodology and subsequently reduced morbidity.
Routine colonic endoscopic evaluation following resolution of acute diverticulitis: Is it necessary?
Agarwal, Amit K; Karanjawala, Burzeen E; Maykel, Justin A; Johnson, Eric K; Steele, Scott R
2014-01-01
Diverticular disease incidence is increasing up to 65% by age 85 in industrialized nations, low fiber diets, and in younger and obese patients. Twenty-five percent of patients with diverticulosis will develop acute diverticulitis. This imposes a significant burden on healthcare systems, resulting in greater than 300000 admissions per year with an estimated annual cost of $3 billion USD. Abdominal computed tomography (CT) is the diagnostic study of choice, with a sensitivity and specificity greater than 95%. Unfortunately, similar CT findings can be present in colonic neoplasia, especially when perforated or inflamed. This prompted professional societies such as the American Society of Colon Rectal Surgeons to recommend patients undergo routine colonoscopy after an episode of acute diverticulitis to rule out malignancy. Yet, the data supporting routine colonoscopy after acute diverticulitis is sparse and based small cohort studies utilizing outdated technology. While any patient with an indication for a colonoscopy should undergo appropriate endoscopic evaluation, in the era of widespread use of high-resolution computed tomography, routine colonic endoscopic evaluation following resolution of acute uncomplicated diverticulitis poses additional costs, comes with inherent risks, and may require further study. In this manuscript, we review the current data related to this recommendation. PMID:25253951
Fibre-optic nonlinear optical microscopy and endoscopy.
Fu, L; Gu, M
2007-06-01
Nonlinear optical microscopy has been an indispensable laboratory tool of high-resolution imaging in thick tissue and live animals. Rapid developments of fibre-optic components in terms of growing functionality and decreasing size provide enormous opportunities for innovations in nonlinear optical microscopy. Fibre-based nonlinear optical endoscopy is the sole instrumentation to permit the cellular imaging within hollow tissue tracts or solid organs that are inaccessible to a conventional optical microscope. This article reviews the current development of fibre-optic nonlinear optical microscopy and endoscopy, which includes crucial technologies for miniaturized nonlinear optical microscopy and their embodiments of endoscopic systems. A particular attention is given to several classes of photonic crystal fibres that have been applied to nonlinear optical microscopy due to their unique properties for ultrashort pulse delivery and signal collection. Furthermore, fibre-optic nonlinear optical imaging systems can be classified into portable microscopes suitable for imaging behaving animals, rigid endoscopes that allow for deep tissue imaging with minimally invasive manners, and flexible endoscopes enabling imaging of internal organs. Fibre-optic nonlinear optical endoscopy is coming of age and a paradigm shift leading to optical microscope tools for early cancer detection and minimally invasive surgery.
NASA Astrophysics Data System (ADS)
Brunetaud, Jean Marc; Maunoury, Vincent; Cochelard, Dominique
1997-01-01
Lasers were introduced in digestive endoscopy to stop active gastroduodenal hemorrhages. Their use spread progressively to the treatment of chronic hemorrhages from vascular malformations and sessile tumors. Laser face competition from other endoscopic techniques such as electrocoagulation, injection techniques, dilation, stents, and brachytherapy. Many series have reported the efficacy of lasers in digestive endoscopy used for their thermal or photochemical effects. However, they were gradually abandoned for the treatment of hemorrhages because of competition from nonlaser techniques. Lasers are still used for ablation of sessile tumors, but their true impact is difficult to evaluate. Modern methods of technology assessment did not allow gastroenterologists to clearly define the place of lasers among surgery, radio-chemotherapy, and other endoscopic techniques, and data on the daily use of lasers are not available. Therefore, the conclusion can only be subjective. The best current application of thermal lasers appears to be in the treatment of rectosigmoid villous adenomas in elderly patients. Small superficial rectal cancers may also become a good subject due to the impact of endoscopic ultrasonography. Early lesions with multifocal or diffuse disease such as early esophageal cancers could be the most promising subject of application for photodynamic therapy in the future.
Medical-grade Sterilizable Target for Fluid-immersed Fetoscope Optical Distortion Calibration
Chadebecq, François; Tella, Marcel; Deprest, Jan; Stoyanov, Danail; Ourselin, Sébastien; Vercauteren, Tom
2017-01-01
We have developed a calibration target for use with fluid-immersed endoscopes within the context of the GIFT-Surg (Guided Instrumentation for Fetal Therapy and Surgery) project. One of the aims of this project is to engineer novel, real-time image processing methods for intra-operative use in the treatment of congenital birth defects, such as spina bifida and the twin-to-twin transfusion syndrome. The developed target allows for the sterility-preserving optical distortion calibration of endoscopes within a few minutes. Good optical distortion calibration and compensation are important for mitigating undesirable effects like radial distortions, which not only hamper accurate imaging using existing endoscopic technology during fetal surgery, but also make acquired images less suitable for potentially very useful image computing applications, like real-time mosaicing. In this paper proposes a novel fabrication method to create an affordable, sterilizable calibration target suitable for use in a clinical setup. This method involves etching a calibration pattern by laser cutting a sandblasted stainless steel sheet. This target was validated using the camera calibration module provided by OpenCV, a state-of-the-art software library popular in the computer vision community. PMID:28287588
Variety and evolution of American endoscopic image management and recording systems.
Korman, L Y
1996-03-01
The rapid evolution of computing technology has and will continue to alter the practice of gastroenterology and gastrointestinal endoscopy. Development of communication standards for text, images, and security systems will be necessary for medicine to take advantage of high-speed computing and communications. Professional societies can have an important role in guiding the development process.
Rigante, M; La Rocca, G; Lauretti, L; D'Alessandris, G Q; Mangiola, A; Anile, C; Olivi, A; Paludetti, G
2017-06-01
During the last two decades endoscopic skull base surgery observed a continuous technical and technological development 3D endoscopy and ultra High Definition (HD) endoscopy have provided great advances in terms of visualisation and spatial resolution. Ultra-high definition (UHD) 4K systems, recently introduced in the clinical practice, will shape next steps forward especially in skull base surgery field. Patients were operated on through transnasal transsphenoidal endoscopic approaches performed using Olympus NBI 4K UHD endoscope with a 4 mm 0° Ultra Telescope, 300 W xenon lamp (CLV-S400) predisposed for narrow band imaging (NBI) technology connected through a camera head to a high-quality control unit (OTV-S400 - VISERA 4K UHD) (Olympus Corporation, Tokyo, Japan). Two screens are used, one 31" Monitor - (LMD-X310S) and one main ultra-HD 55" screen optimised for UHD image reproduction (LMD-X550S). In selected cases, we used a navigation system (Stealthstation S7, Medtronic, Minneapolis, MN, US). We evaluated 22 pituitary adenomas (86.3% macroadenomas; 13.7% microadenomas). 50% were not functional (NF), 22.8% GH, 18.2% ACTH, 9% PRL-secreting. Three of 22 were recurrences. In 91% of cases we achieved total removal, while in 9% near total resection. A mean follow-up of 187 days and average length of hospitalisation was 3.09 ± 0.61 days. Surgical duration was 128.18± 30.74 minutes. We experienced only 1 case of intraoperative low flow fistula with no further complications. None of the cases required any post- or intraoperative blood transfusion. The visualisation and high resolution of the operative field provided a very detailed view of all anatomical structures and pathologies allowing an improvement in safety and efficacy of the surgical procedure. The operative time was similar to the standard 2D HD and 3D procedures and the physical strain was also comparable to others in terms of ergonomics and weight. © Copyright by Società Italiana di Otorinolaringologia e Chirurgia Cervico-Facciale, Rome, Italy.
Park, Soon Hong; Sung, Sang Hun; Lee, Seung Jun; Jung, Min Kyu; Kim, Sung Kook
2012-01-01
Purpose Gastric mucosal neoplastic lesions should have characteristic endoscopic features for successful endoscopic submucosal dissection. Materials and Methods Out of the 1,010 endoscopic submucosal dissection, we enrolled 62 patients that had the procedure cancelled. Retrospectively, whether the reasons for cancelling the endoscopic submucosal dissection were consistent with the indications for an endoscopic submucosal dissection were assessed by analyzing the clinical outcomes of the patients that had the surgery. Results The cases were divided into two groups; the under-diagnosed group (30 cases; unable to perform an endoscopic submucosal dissection) and the over-diagnosed group (32 cases; unnecessary to perform an endoscopic submucosal dissection), according to the second endoscopic findings, compared with the index conventional white light image. There were six cases in the under-diagnosed group with advanced gastric cancer on the second conventional white light image endoscopy, 17 cases with submucosal invasion on endoscopic ultrasonography findings, 5 cases with a size greater than 3 cm and ulcer, 1 case with diffuse infiltrative endoscopic features, and 1 case with lymph node involvement on computed tomography. A total of 25 patients underwent a gastrectomy to remove a gastric adenocarcinoma. The overall accuracy of the decision to cancel the endoscopic submucosal dissection was 40% (10/25) in the subgroup that had the surgery. Conclusions The accuracy of the decision to cancel the endoscopic submucosal dissection, after conventional white light image and endoscopic ultrasonography, was low in this study. Other diagnostic options are needed to arrive at an accurate decision on whether to perform a gastric endoscopic submucosal dissection. PMID:22792522
2014-01-01
Background Gossypiboma is a term used to describe a mass that forms around a cotton sponge or abdominal compress accidentally left in a patient during surgery. Transmural migration of an intra-abdominal gossypiboma has been reported to occur in the digestive tract, bladder, vagina and diaphragm. Open surgery is the most common approach in the treatment of gossypiboma. However, gossypibomas can be extracted by endoscopy while migrating into the digestive tract. We report a case of intractable duodenal ulcer caused by transmural migration of gossypiboma successfully treated by duodenorrhaphy. A systemic literature review is provided and a scheme of the therapeutic approach is proposed. Case presentation A 61-year-old Han Chinese man presented with intermittent epigastric pain for the last 10 months. He had undergone laparoscopic cholecystectomy conversion to open cholecystectomy for acute gangrenous cholecystitis 10 months ago at another hospital. Transmural migration of gossypiboma into the duodenum was found. Endoscopic intervention failed to remove the entire gauze, and duodenal ulcer caused by the gauze persisted. Surgical intervention was performed and the gauze was removed successfully. The penetrated ulcer was repaired with duodenorrhaphy. The postoperative period was uneventful. We systematically reviewed the literature on transmural migration of gossypiboma into duodenum and present an overview of published cases. Our PubMed search yielded seven reports of transmural migration of retained surgical sponge into the duodenum. Surgical interventions were necessary in two patients. Conclusion Transmural migration of gossypiboma into the duodenum is a rare surgical complication. The treatment strategies include endoscopic extraction and surgical intervention. Prompt surgical intervention should be considered for emergent conditions such as active bleeding, gastrointestinal obstruction, or intra-abdominal sepsis. For non-emergent conditions, surgical intervention could be considered for intractable cases in which endoscopic extraction failed. PMID:24917191
Etiology and management of esophageal impaction in children: A review of 11 years.
Alrazzak, Baraa Alabd; Al-Subu, Awni; Elitsur, Yoram
2013-04-01
Esophageal impaction in children is a medical emergency that needs an immediate medical attention. In the last years multiple objects have been detected and were removed endoscopically. In the last decade, Eosinophilic Esophagitis (EoE) has been associated with esophageal stenosis, leading to esophageal impaction with various objects including toys, food, coins and other. To determine the various objects and symptoms associated with impactions and to develop algorithm that guides Emergency Department Physicians and Primary care Providers when facing such problem in pediatric patient. A retrospective chart review of all children referred to the pediatric gastroenterology service at Marshall University for FB impaction between 2000 and 2010 was performed. Foreign bodies treated by other specialties were excluded from this review. Clinical and demographic data were retrieved. A total of 291 charts with the diagnosis of foreign body reviewed of which only 126 met the inclusion criteria and considered for final calculation. Male/Female ratio and mean age were 1.17:1.0, and 3.65 ± 0.75 years, respectively. Time of impaction before ER evaluation was: < 24hrs in 75 patients, >24hrs in 17 and in 34 the time of ingestion was not known. Radiology was performed in 118 patients, of whom 1 had pneumo-mediastinum and 1 had pneumothorax. Endoscopic localization of the objects showed: 81- proximal, 23- middle esophagus, and 22- in the distal esophagus. The esophageal mucosa showed non-specific changes in 37 patients, 5 with EoE features, 1 patient with hiatal hernia, 1 patient with candidiasis, and in 5 pts had no mucosal description. Children with foreign body in the esophagus are commonly seen in our Hospital ER. Those children may harbor undiagnosed medical conditions that will need future therapy. Careful endoscopic assessment with mucosal biopsies is needed to diagnose those conditions earlier. Referral to a GI specialist may be warranted.
Novel Concept of Attaching Endoscope Holder to Microscope for Two Handed Endoscopic Tympanoplasty.
Khan, Mubarak M; Parab, Sapna R
2016-06-01
The well established techniques in tympanoplasty are routinely performed with operating microscopes for many decades now. Endoscopic ear surgeries provide minimally invasive approach to the middle ear and evolving new science in the field of otology. The disadvantage of endoscopic ear surgeries is that it is one-handed surgical technique as the non-dominant left hand of the surgeon is utilized for holding and manipulating the endoscope. This necessitated the need for development of the endoscope holder which would allow both hands of surgeon to be free for surgical manipulation and also allow alternate use of microscope during tympanoplasty. To report the preliminary utility of our designed and developed endoscope holder attachment gripping to microscope for two handed technique of endoscopic tympanoplasty. Prospective Non Randomized Clinical Study. Our endoscope holder attachment for microscope was designed and developed to aid in endoscopic ear surgery and to overcome the disadvantage of single handed endoscopic surgery. It was tested for endoscopic Tympanoplasty. The design of the endoscope holder attachment is described in detail along with its manipulation and manoeuvreing. A total of 78 endoholder assisted type 1 endoscopic cartilage tympanoplasties were operated to evaluate its feasibility for the two handed technique and to evaluate the results of endoscopic type 1 cartilage tympanoplasty. In early follow up period ranging from 6 to 20 months, the graft uptake was seen in 76 ears with one residual perforation and 1 recurrent perforations giving a success rate of 97.435 %. Our endocsope holder attachment for gripping microscope is a good option for two handed technique in endoscopic type 1 cartilage tympanoplasty. The study reports the successful application and use of our endoscope holder attachment for gripping microscope in two handed technique of endoscopic type 1 cartilage tympanoplasty and comparable results with microscopic techniques. IV.
Smartphone-Based Endoscope System for Advanced Point-of-Care Diagnostics: Feasibility Study
Bae, Jung Kweon; Vavilin, Andrey; You, Joon S; Kim, Hyeongeun; Ryu, Seon Young; Jang, Jeong Hun
2017-01-01
Background Endoscopic technique is often applied for the diagnosis of diseases affecting internal organs and image-guidance of surgical procedures. Although the endoscope has become an indispensable tool in the clinic, its utility has been limited to medical offices or operating rooms because of the large size of its ancillary devices. In addition, the basic design and imaging capability of the system have remained relatively unchanged for decades. Objective The objective of this study was to develop a smartphone-based endoscope system capable of advanced endoscopic functionalities in a compact size and at an affordable cost and to demonstrate its feasibility of point-of-care through human subject imaging. Methods We developed and designed to set up a smartphone-based endoscope system, incorporating a portable light source, relay-lens, custom adapter, and homebuilt Android app. We attached three different types of existing rigid or flexible endoscopic probes to our system and captured the endoscopic images using the homebuilt app. Both smartphone-based endoscope system and commercialized clinical endoscope system were utilized to compare the imaging quality and performance. Connecting the head-mounted display (HMD) wirelessly, the smartphone-based endoscope system could superimpose an endoscopic image to real-world view. Results A total of 15 volunteers who were accepted into our study were captured using our smartphone-based endoscope system, as well as the commercialized clinical endoscope system. It was found that the imaging performance of our device had acceptable quality compared with that of the conventional endoscope system in the clinical setting. In addition, images captured from the HMD used in the smartphone-based endoscope system improved eye-hand coordination between the manipulating site and the smartphone screen, which in turn reduced spatial disorientation. Conclusions The performance of our endoscope system was evaluated against a commercial system in routine otolaryngology examinations. We also demonstrated and evaluated the feasibility of conducting endoscopic procedures through a custom HMD. PMID:28751302
Katiyar, Prashant; Nijhawan, Sandeep; Saradava, Vimal; Nagaich, Neeraj; Gupta, Gaurav; Mathur, Amit; Nepalia, Subhash
2013-11-01
Endoscopic balloon dilatation (EBD) is an effective therapy for caustic-induced gastric outlet obstruction (GOO). Gaining access to the stricture site is the most important step. It is sometimes difficult to negotiate a balloon through the stricture with a front-viewing endoscope due to deformed anatomy of stomach. To overcome this technical difficulty, a side-viewing endoscope can be used. There is limited data regarding the use of side-viewing endoscopes in EBD. We here report on the short-term efficacy and safety of EBD in caustic-induced GOO. In technically difficult cases, a side-viewing endoscope was used for EBD and its efficacy and safety were assessed. The study included 25 patients with caustic-induced GOO. Patients underwent EBD using a through-the-scope balloon. Initial balloon dilatation was performed with a front-viewing endoscope. A side-viewing endoscope was used where negotiation across the stricture failed with a front-viewing endoscope. Dilatation was started at 8 mm diameter and was performed at 1-week intervals. The end point of dilatation was 15 mm diameter. In 18 patients successful balloon dilatation was possible with a front-viewing endoscope. A side-viewing endoscope was used in six patients as negotiation across the stricture was not possible with a front-viewing endoscope. In all six patients negotiation across the stricture followed by successful dilatation was successful with a side-viewing endoscope. Of the 25 patients included in this study, 24 (96%) achieved procedural success (18 with a front-viewing endoscope and 6 with a side-viewing endoscope) in 3-9 sessions. Our results show that EBD is a safe and effective option for caustic-induced GOO and in difficult cases a side-viewing endoscope can be used to achieve technical success.
Technological innovations in surgical approach for thyroid cancer.
Lang, Brian Hung-Hin; Lo, Chung-Yau
2010-01-01
Over the last decade, surgeons have witnessed dramatic changes in surgical practice as a result of the introduction of new technological advancement. Some of these changes include refinement of techniques in thyroid cancer surgery. The development of various endoscopic thyroidectomy techniques, the addition of the da Vinci robot, and the use of operative adjuncts in thyroid surgery, such as intraoperative neuromonitoring and quick intraoperative parathyroid hormone, have made thyroid cancer surgery not only safer and better accepted by patients with thyroid cancer but also offer them more surgical treatment options.
Potential capacity of endoscopic screening for gastric cancer in Japan.
Hamashima, Chisato; Goto, Rei
2017-01-01
In 2016, the Japanese government decided to introduce endoscopic screening for gastric cancer as a national program. To provide endoscopic screening nationwide, we estimated the proportion of increase in the number of endoscopic examinations with the introduction of endoscopic screening, based on a national survey. The total number of endoscopic examinations has increased, particularly in clinics. Based on the national survey, the total number of participants in gastric cancer screening was 3 784 967. If 30% of the participants are switched from radiographic screening to endoscopic screening, approximately 1 million additional endoscopic examinations are needed. In Japan, the participation rates in gastric cancer screening and the number of hospitals and clinics offering upper gastrointestinal endoscopy vary among the 47 prefectures. If the participation rates are high and the numbers of hospitals and clinics are small, the proportion of increase becomes larger. Based on the same assumption, 50% of big cities can provide endoscopic screening with a 5% increase in the total number of endoscopic examinations. However, 16.7% of the medical districts are available for endoscopic screening within a 5% increase in the total number of endoscopic examinations. Despite the Japanese government's decision to introduce endoscopic screening for gastric cancer nationwide, its immediate introduction remains difficult because of insufficient medical resources in rural areas. This implies that endoscopic screening will be initially introduced to big cities. To promote endoscopic screening for gastric cancer nationwide, the disparity of medical resources must first be resolved. © 2016 The Authors. Cancer Science published by John Wiley & Sons Australia, Ltd on behalf of Japanese Cancer Association.
Shariff, Mohammed K; Varghese, Sibu; O'Donovan, Maria; Abdullahi, Zarah; Liu, Xinxue; Fitzgerald, Rebecca C; di Pietro, Massimiliano
2016-02-01
The transnasal endosheath endoscope is a new disposable technology with potential applicability to the primary care setting. The aim of this study was to evaluate the efficacy of transnasal endosheath endoscopy (TEE) for the detection of Barrett's esophagus, by comparing the diagnostic accuracy of TEE with that of standard endoscopy. This was a prospective, randomized, crossover study performed in a single tertiary referral center. Consecutive patients undergoing surveillance for Barrett's esophagus or referred for diagnostic assessment were recruited. All patients were randomized to undergo TEE followed by standard endoscopy or the reverse. Endoscopy experiences and patient preferences were evaluated using a questionnaire. Endoscopic and histologic diagnosis of Barrett's esophagus, and optical image quality of both endoscopic procedures, were compared. A total of 21 of 25 patients completed the study. TEE had sensitivity and specificity of 100 % for an endoscopic diagnosis of Barrett's esophagus, and of 66.7 % and 100 %, respectively, for the histologic diagnosis of Barrett's esophagus. The mean optical quality of standard endoscopy was significantly better than that of TEE (7.11 ± 0.42 vs. 4.06 ± 0.27; P < 0.0001). However, following endoscopy, patients reported a significantly better experience with TEE compared with standard endoscopy (7.05 ± 0.49 vs. 4.35 ± 0.53; P = 0.0006), with 60 % preferring TEE and 25 % preferring sedated standard endoscopy. In this study, TEE had equal accuracy for an endoscopic diagnosis of Barrett's esophagus compared with standard endoscopy, at the expense of reduced image quality and a lower yield of intestinal metaplasia on biopsy. TEE was better tolerated and preferred by patients. Hence, TEE needs further evaluation in primary care as an initial diagnostic tool. © Georg Thieme Verlag KG Stuttgart · New York.
Travis, Simon P L; Danese, Silvio; Kupcinskas, Limas; Alexeeva, Olga; D'Haens, Geert; Gibson, Peter R; Moro, Luigi; Jones, Richard; Ballard, E David; Masure, Johan; Rossini, Matteo; Sandborn, William J
2014-01-01
Objective Budesonide MMX is a novel oral formulation of budesonide that uses Multi-Matrix System (MMX) technology to extend release to the colon. This study compared the efficacy of budesonide MMX with placebo in patients with active, mild-to-moderate ulcerative colitis (UC). Design Patients were randomised 1:1:1:1 to receive budesonide MMX 9 mg or 6 mg, or Entocort EC 9 mg (budesonide controlled ileal-release capsules; reference arm) or placebo once daily for 8 weeks. The primary endpoint was combined clinical and endoscopic remission, defined as UC Disease Activity Index score ≤1 with a score of 0 for rectal bleeding and stool frequency, no mucosal friability on colonoscopy, and a ≥1-point reduction in endoscopic index score from baseline. Results 410 patients were evaluated for efficacy. Combined clinical and endoscopic remission rates with budesonide MMX 9 mg or 6 mg, Entocort EC and placebo were 17.4%, 8.3%, 12.6% and 4.5%, respectively. The difference between budesonide MMX 9 mg and placebo was significant (OR 4.49; 95% CI 1.47 to 13.72; p=0.0047). Budesonide MMX 9 mg was associated with numerically higher rates of clinical (42.2% vs 33.7%) and endoscopic improvement (42.2% vs 31.5%) versus placebo. The rate of histological healing (16.5% vs 6.7%; p=0.0361) and proportion of patients with symptom resolution (23.9% vs 11.2%; p=0.0220) were significantly higher for budesonide MMX 9 mg than placebo. Adverse event profiles were similar across groups. Conclusion Budesonide MMX 9 mg was safe and more effective than placebo at inducing combined clinical and endoscopic remission in patients with active, mild-to-moderate UC. PMID:23436336
Loukas, Constantinos; Lahanas, Vasileios; Georgiou, Evangelos
2013-12-01
Despite the popular use of virtual and physical reality simulators in laparoscopic training, the educational potential of augmented reality (AR) has not received much attention. A major challenge is the robust tracking and three-dimensional (3D) pose estimation of the endoscopic instrument, which are essential for achieving interaction with the virtual world and for realistic rendering when the virtual scene is occluded by the instrument. In this paper we propose a method that addresses these issues, based solely on visual information obtained from the endoscopic camera. Two different tracking algorithms are combined for estimating the 3D pose of the surgical instrument with respect to the camera. The first tracker creates an adaptive model of a colour strip attached to the distal part of the tool (close to the tip). The second algorithm tracks the endoscopic shaft, using a combined Hough-Kalman approach. The 3D pose is estimated with perspective geometry, using appropriate measurements extracted by the two trackers. The method has been validated on several complex image sequences for its tracking efficiency, pose estimation accuracy and applicability in AR-based training. Using a standard endoscopic camera, the absolute average error of the tip position was 2.5 mm for working distances commonly found in laparoscopic training. The average error of the instrument's angle with respect to the camera plane was approximately 2°. The results are also supplemented by video segments of laparoscopic training tasks performed in a physical and an AR environment. The experiments yielded promising results regarding the potential of applying AR technologies for laparoscopic skills training, based on a computer vision framework. The issue of occlusion handling was adequately addressed. The estimated trajectory of the instruments may also be used for surgical gesture interpretation and assessment. Copyright © 2013 John Wiley & Sons, Ltd.
Historical review of arthroscopic surgery of the hip.
Magrill, Abigail C L; Nakano, Naoki; Khanduja, Vikas
2017-10-01
Increasing our appreciation of the historical foundations of hip arthroscopy offers greater insight and understanding of the field's current and future applications. This article offers a broad history of the progress of hip arthroscopy. Hip arthroscopy's development from the early technologies of endoscopy to the present day is described through a review of the available literature. Endoscopic science begins with the Lichtleiter, developed by Phillip Bozzini (1779-1809) in 1806, but endoscopes were not applied to joints until 1912, as presented by Severin Nordentoft (1866-1922). The work of Kenji Takagi (1888-1963), especially, was instrumental in the arthroscope's development, allowing Michael Burman (1901-75) to perform the first recorded hip arthroscopy, detailed in a 1931 paper after extensive cadaveric research. Although World War II stalled further development, a renewed application of fibre optics following post-war innovations in glass manufacture heralded the modern arthroscope's invention. During the 1970s hip arthroscopy was first mobilized for diagnosis and exploration, leading to its later adoption for therapeutic surgical interventions. Modern hip arthroscopy has been facilitated by international research into optimum distraction, portals of entry, positioning of patients, and the technology of arthroscopic instruments. In 2008, the International Society for Hip Arthroscopy (ISHA) was founded to represent this international expert community. Technology, communication and evidence-based medicine have jointly facilitated the development of this young but promising corner of Orthopaedics.
NASA Astrophysics Data System (ADS)
Deng, Shengfeng; Lyu, Jinke; Sun, Hongda; Cui, Xiaobin; Wang, Tun; Lu, Miao
2015-03-01
A chirped artificial compound eye on a curved surface was fabricated using an optical resin and then mounted on the end of an endoscopic imaging fiber bundle. The focal length of each lenslet on the curved surface was variable to realize a flat focal plane, which matched the planar end surface of the fiber bundle. The variation of the focal length was obtained by using a photoresist mold formed by dose-modulated laser lithography and subsequent thermal reflow. The imaging performance of the fiber bundle was characterized by coupling with a coaxial light microscope, and the result demonstrated a larger field of view and better imaging quality than that of an artificial compound eye with a uniform focal length. Accordingly, this technology has potential application in stereoscopic endoscopy.
Renal surgery in the new millennium.
Delvecchio, F C; Preminger, G M
2000-11-01
In the not too distant future, the minimally invasive renal surgeon will be able to practice an operation on a difficult case on a three-dimensional virtual reality simulator, providing all attributes of the real procedure. The patient's imaging studies will be imported into the simulator to better mimic particular anatomy. When confident enough of his or her skills, the surgeon will start operating on the patient using the same virtual reality simulator/telepresence surgery console system, which will permit the live surgery to be conducted by robots hundreds of miles away. The robots will manipulate miniature endoscopes or control minimally or noninvasive ablative technologies. Endoscopic/laparoscopic footage of the surgical procedure will be stored digitally in optical disks to be used later in telementoring of a surgery resident. All this and more will be possible in the not so distant third millennium.
Contrast-enhanced endoscopic ultrasonography: advance and current status
2014-01-01
Endoscopic ultrasonography (EUS) technology has undergone a great deal of progress along with the color and power Doppler imaging, three-dimensional imaging, electronic scanning, tissue harmonic imaging, and elastography, and one of the most important developments is the ability to acquire contrast-enhanced images. The blood flow in small vessels and the parenchymal microvasculature of the target lesion can be observed non-invasively by contrast-enhanced EUS (CE-EUS). Through a hemodynamic analysis, CE-EUS permits the diagnosis of various gastrointestinal diseases and differential diagnoses between benign and malignant tumors. Recently, mechanical innovations and the development of contrast agents have increased the use of CE-EUS in the diagnostic field, as well as for the assessment of the efficacy of therapeutic agents. The advances in and the current status of CE-EUS are discussed in this review. PMID:25038805
Dynamic focus-tracking MEMS scanning micromirror with low actuation voltages for endoscopic imaging
Strathman, Matthew; Liu, Yunbo; Li, Xingde; Lin, Lih Y.
2013-01-01
We demonstrate a 3-D scanning micromirror device that combines 2-D beam scanning with focus control in the same device using micro-electro-mechanical-systems (MEMS) technology. 2-D beam scanning is achieved with a biaxial gimbal structure and focus control is obtained with a deformable mirror membrane surface. The micromirror with 800 micrometer diameter is designed to be sufficiently compact and efficient so that it can be incorporated into an endoscopic imaging probe in the future. The design, fabrication and characterization of the device are described in this paper. Using the focus-tracking MEMS scanning mirror, we achieved an optical scanning range of >16 degrees with <40 V actuation voltage at resonance and a tunable focal length between infinity and 25 mm with <100V applied bias. PMID:24104304
Latest generation, wide-angle, high-definition colonoscopes increase adenoma detection rate.
Adler, Andreas; Aminalai, Alireza; Aschenbeck, Jens; Drossel, Rolf; Mayr, Michael; Scheel, Mathias; Schröder, Andreas; Yenerim, Timur; Wiedenmann, Bertram; Gauger, Ulrich; Roll, Stephanie; Rösch, Thomas
2012-02-01
Improvements to endoscopy imaging technologies might improve detection rates of colorectal cancer and patient outcomes. We compared the accuracy of the latest generation of endoscopes with older generation models in detection of colorectal adenomas. We compared data from 2 prospective screening colonoscopy studies (the Berlin Colonoscopy Project 6); each study lasted approximately 6 months and included the same 6 colonoscopists, who worked in private practice. Participants in group 1 (n = 1256) were all examined by using the latest generation of wide-angle, high-definition colonoscopes that were manufactured by the same company. Individuals in group 2 (n = 1400) were examined by endoscopists who used routine equipment (a mixture of endoscopes from different companies; none of those used to examine group 1). The adenoma detection rate was calculated on the basis of the number of all adenomas/number of all patients. There were no differences in patient parameters or withdrawal time between groups (8.0 vs 8.2 minutes). The adenoma detection rate was significantly higher in group 1 (0.33) than in group 2 (0.27; P = .01); a greater number of patients with least 1 adenoma were identified in group 1 (22.1%) than in group 2 (18.2%; P = .01). A higher percentage of high-grade dysplastic adenomas were detected in group 1 (1.19%) than in group 2 (0.57%), but this difference was not statistically significant (P = .06). The latest generation of wide-angle, high-definition colonoscopes improves rates of adenoma detection by 22%, compared with mixed, older technology endoscopes used in routine private practice. These findings might affect definitions of quality control parameters for colonoscopy screening for colorectal cancer. Copyright © 2012 AGA Institute. Published by Elsevier Inc. All rights reserved.
Optical characterization and polarization calibration for rigid endoscopes
NASA Astrophysics Data System (ADS)
Garcia, Missael; Gruev, Viktor
2017-02-01
Polarization measurements give orthogonal information to spectral images making them a great tool in the characterization of environmental parameters in nature. Thus, polarization imagery has proven to be remarkably useful in a vast range of biomedical applications. One such application is the early diagnosis of flat cancerous lesions in murine colorectal tumor models, where polarization data complements NIR fluorescence analysis. Advances in nanotechnology have led to compact and precise bio-inspired imaging sensors capable of accurately co-registering multidimensional spectral and polarization information. As more applications emerge for these imagers, the optics used in these instruments get very complex and can potentially compromise the original polarization state of the incident light. Here we present a complete optical and polarization characterization of three rigid endoscopes of size 1.9mm x 10cm (Karl Storz, Germany), 5mm x 30cm, and 10mm x 33cm (Olympus, Germany), used in colonoscopy for the prevention of colitis-associated cancer. Characterization results show that the telescope optics act as retarders and effectively depolarize the linear component. These incorrect readings can cause false-positives or false-negatives leading to an improper diagnosis. In this paper, we offer a polarization calibration scheme for these endoscopes based on Mueller calculus. By modeling the optical properties from training data as real-valued Mueller matrices, we are able to successfully reconstruct the initial polarization state acquired by the imaging system.
NASA Astrophysics Data System (ADS)
Waterhouse, Dale J.; Joseph, James; Neves, Andre A.; di Pietro, Massimiliano; Brindle, Kevin M.; Fitzgerald, Rebecca C.; Bohndiek, Sarah E.
2016-03-01
Barrett's esophagus is a condition that predisposes patients to esophageal cancer. Early detection of cancer in these patients can be curative, but is confounded by a lack of contrast in white light endoscopy (WLE). Application of fluorescently-labeled lectins to the esophagus during endoscopy can more accurately delineate dysplasia emerging within Barrett's than WLE1, but strong tissue autofluorescence has limited sensitivity and dynamic range of this approach. To overcome this challenge, we synthesized a near-infrared (NIR) fluorescent lectin and have constructed a clinically translatable endoscope for simultaneous WLE and NIR imaging. An imaging fiber bundle, shielded from patient contact using a disposable catheter, relays collected light into an optical path that splits the WL reflectance and NIR emission onto two cameras for simultaneous video-rate recording. The captured images are co-registered and the honeycomb artifact arising from the fiber bundle is removed using interpolation between image points derived from individual fibers. A minimum detectable concentration of 110 nM was determined using a dilution series of IRDye800CW-lectin in black well plates. We have demonstrated the ability to use our endoscope to distinguish between different tissue types in ex vivo mouse stomachs. Future work using human ex vivo tissue specimens will determine safe illumination limits and sensitivity for dysplasia and adenocarcinoma in Barrett's esophagus, prior to commencing clinical trials.
Advances in laparoscopy for acute care surgery and trauma
Mandrioli, Matteo; Inaba, Kenji; Piccinini, Alice; Biscardi, Andrea; Sartelli, Massimo; Agresta, Ferdinando; Catena, Fausto; Cirocchi, Roberto; Jovine, Elio; Tugnoli, Gregorio; Di Saverio, Salomone
2016-01-01
The greatest advantages of laparoscopy when compared to open surgery include the faster recovery times, shorter hospital stays, decreased postoperative pain, earlier return to work and resumption of normal daily activity as well as cosmetic benefits. Laparoscopy today is considered the gold standard of care in the treatment of cholecystitis and appendicitis worldwide. Laparoscopy has even been adopted in colorectal surgery with good results. The technological improvements in this surgical field along with the development of modern techniques and the acquisition of specific laparoscopic skills have allowed for its utilization in operations with fully intracorporeal anastomoses. Further progress in laparoscopy has included single-incision laparoscopic surgery and natural orifice trans-luminal endoscopic surgery. Nevertheless, laparoscopy for emergency surgery is still considered challenging and is usually not recommended due to the lack of adequate experience in this area. The technical difficulties of operating in the presence of diffuse peritonitis or large purulent collections and diffuse adhesions are also given as reasons. However, the potential advantages of laparoscopy, both in terms of diagnosis and therapy, are clear. Major advantages may be observed in cases with diffuse peritonitis secondary to perforated peptic ulcers, for example, where laparoscopy allows the confirmation of the diagnosis, the identification of the position of the ulcer and a laparoscopic repair with effective peritoneal washout. Laparoscopy has also revolutionized the approach to complicated diverticulitis even when intestinal perforation is present. Many other emergency conditions can be effectively managed laparoscopically, including trauma in select hemodynamically-stable patients. We have therefore reviewed the most recent scientific literature on advances in laparoscopy for acute care surgery and trauma in order to demonstrate the current indications and outcomes associated with a laparoscopic approach to the treatment of the most common emergency surgical conditions. PMID:26811616
Advances in laparoscopy for acute care surgery and trauma.
Mandrioli, Matteo; Inaba, Kenji; Piccinini, Alice; Biscardi, Andrea; Sartelli, Massimo; Agresta, Ferdinando; Catena, Fausto; Cirocchi, Roberto; Jovine, Elio; Tugnoli, Gregorio; Di Saverio, Salomone
2016-01-14
The greatest advantages of laparoscopy when compared to open surgery include the faster recovery times, shorter hospital stays, decreased postoperative pain, earlier return to work and resumption of normal daily activity as well as cosmetic benefits. Laparoscopy today is considered the gold standard of care in the treatment of cholecystitis and appendicitis worldwide. Laparoscopy has even been adopted in colorectal surgery with good results. The technological improvements in this surgical field along with the development of modern techniques and the acquisition of specific laparoscopic skills have allowed for its utilization in operations with fully intracorporeal anastomoses. Further progress in laparoscopy has included single-incision laparoscopic surgery and natural orifice trans-luminal endoscopic surgery. Nevertheless, laparoscopy for emergency surgery is still considered challenging and is usually not recommended due to the lack of adequate experience in this area. The technical difficulties of operating in the presence of diffuse peritonitis or large purulent collections and diffuse adhesions are also given as reasons. However, the potential advantages of laparoscopy, both in terms of diagnosis and therapy, are clear. Major advantages may be observed in cases with diffuse peritonitis secondary to perforated peptic ulcers, for example, where laparoscopy allows the confirmation of the diagnosis, the identification of the position of the ulcer and a laparoscopic repair with effective peritoneal washout. Laparoscopy has also revolutionized the approach to complicated diverticulitis even when intestinal perforation is present. Many other emergency conditions can be effectively managed laparoscopically, including trauma in select hemodynamically-stable patients. We have therefore reviewed the most recent scientific literature on advances in laparoscopy for acute care surgery and trauma in order to demonstrate the current indications and outcomes associated with a laparoscopic approach to the treatment of the most common emergency surgical conditions.
Advanced Endoscopic Navigation: Surgical Big Data, Methodology, and Applications.
Luo, Xiongbiao; Mori, Kensaku; Peters, Terry M
2018-06-04
Interventional endoscopy (e.g., bronchoscopy, colonoscopy, laparoscopy, cystoscopy) is a widely performed procedure that involves either diagnosis of suspicious lesions or guidance for minimally invasive surgery in a variety of organs within the body cavity. Endoscopy may also be used to guide the introduction of certain items (e.g., stents) into the body. Endoscopic navigation systems seek to integrate big data with multimodal information (e.g., computed tomography, magnetic resonance images, endoscopic video sequences, ultrasound images, external trackers) relative to the patient's anatomy, control the movement of medical endoscopes and surgical tools, and guide the surgeon's actions during endoscopic interventions. Nevertheless, it remains challenging to realize the next generation of context-aware navigated endoscopy. This review presents a broad survey of various aspects of endoscopic navigation, particularly with respect to the development of endoscopic navigation techniques. First, we investigate big data with multimodal information involved in endoscopic navigation. Next, we focus on numerous methodologies used for endoscopic navigation. We then review different endoscopic procedures in clinical applications. Finally, we discuss novel techniques and promising directions for the development of endoscopic navigation.
Dhar, Anjan; Close, Helen; Viswanath, Yirupaiahgari K; Rees, Colin J; Hancock, Helen C; Dwarakanath, A Deepak; Maier, Rebecca H; Wilson, Douglas; Mason, James M
2014-12-28
To undertake a randomised pilot study comparing biodegradable stents and endoscopic dilatation in patients with strictures. This British multi-site study recruited seventeen symptomatic adult patients with refractory strictures. Patients were randomised using a multicentre, blinded assessor design, comparing a biodegradable stent (BS) with endoscopic dilatation (ED). The primary endpoint was the average dysphagia score during the first 6 mo. Secondary endpoints included repeat endoscopic procedures, quality of life, and adverse events. Secondary analysis included follow-up to 12 mo. Sensitivity analyses explored alternative estimation methods for dysphagia and multiple imputation of missing values. Nonparametric tests were used. Although both groups improved, the average dysphagia scores for patients receiving stents were higher after 6 mo: BS-ED 1.17 (95%CI: 0.63-1.78) P = 0.029. The finding was robust under different estimation methods. Use of additional endoscopic procedures and quality of life (QALY) estimates were similar for BS and ED patients at 6 and 12 mo. Concomitant use of gastrointestinal prescribed medication was greater in the stent group (BS 5.1, ED 2.0 prescriptions; P < 0.001), as were related adverse events (BS 1.4, ED 0.0 events; P = 0.024). Groups were comparable at baseline and findings were statistically significant but numbers were small due to under-recruitment. The oesophageal tract has somatic sensitivity and the process of the stent dissolving, possibly unevenly, might promote discomfort or reflux. Stenting was associated with greater dysphagia, co-medication and adverse events. Rigorously conducted and adequately powered trials are needed before widespread adoption of this technology.
NASA Astrophysics Data System (ADS)
Qin, Zhuanping; Ma, Wenjuan; Ren, Shuyan; Geng, Liqing; Li, Jing; Yang, Ying; Qin, Yingmei
2017-02-01
Endoscopic DOT has the potential to apply to cancer-related imaging in tubular organs. Although the DOT has relatively large tissue penetration depth, the endoscopic DOT is limited by the narrow space of the internal tubular tissue, so as to the relatively small penetration depth. Because some adenocarcinomas including cervical adenocarcinoma are located in deep canal, it is necessary to improve the imaging resolution under the limited measurement condition. To improve the resolution, a new FOCUSS algorithm along with the image reconstruction algorithm based on the effective detection range (EDR) is developed. This algorithm is based on the region of interest (ROI) to reduce the dimensions of the matrix. The shrinking method cuts down the computation burden. To reduce the computational complexity, double conjugate gradient method is used in the matrix inversion. For a typical inner size and optical properties of the cervix-like tubular tissue, reconstructed images from the simulation data demonstrate that the proposed method achieves equivalent image quality to that obtained from the method based on EDR when the target is close the inner boundary of the model, and with higher spatial resolution and quantitative ratio when the targets are far from the inner boundary of the model. The quantitative ratio of reconstructed absorption and reduced scattering coefficient can be up to 70% and 80% under 5mm depth, respectively. Furthermore, the two close targets with different depths can be separated from each other. The proposed method will be useful to the development of endoscopic DOT technologies in tubular organs.
Dhar, Anjan; Close, Helen; Viswanath, Yirupaiahgari K; Rees, Colin J; Hancock, Helen C; Dwarakanath, A Deepak; Maier, Rebecca H; Wilson, Douglas; Mason, James M
2014-01-01
AIM: To undertake a randomised pilot study comparing biodegradable stents and endoscopic dilatation in patients with strictures. METHODS: This British multi-site study recruited seventeen symptomatic adult patients with refractory strictures. Patients were randomised using a multicentre, blinded assessor design, comparing a biodegradable stent (BS) with endoscopic dilatation (ED). The primary endpoint was the average dysphagia score during the first 6 mo. Secondary endpoints included repeat endoscopic procedures, quality of life, and adverse events. Secondary analysis included follow-up to 12 mo. Sensitivity analyses explored alternative estimation methods for dysphagia and multiple imputation of missing values. Nonparametric tests were used. RESULTS: Although both groups improved, the average dysphagia scores for patients receiving stents were higher after 6 mo: BS-ED 1.17 (95%CI: 0.63-1.78) P = 0.029. The finding was robust under different estimation methods. Use of additional endoscopic procedures and quality of life (QALY) estimates were similar for BS and ED patients at 6 and 12 mo. Concomitant use of gastrointestinal prescribed medication was greater in the stent group (BS 5.1, ED 2.0 prescriptions; P < 0.001), as were related adverse events (BS 1.4, ED 0.0 events; P = 0.024). Groups were comparable at baseline and findings were statistically significant but numbers were small due to under-recruitment. The oesophageal tract has somatic sensitivity and the process of the stent dissolving, possibly unevenly, might promote discomfort or reflux. CONCLUSION: Stenting was associated with greater dysphagia, co-medication and adverse events. Rigorously conducted and adequately powered trials are needed before widespread adoption of this technology. PMID:25561787
Endoscopic laser range scanner for minimally invasive, image guided kidney surgery
NASA Astrophysics Data System (ADS)
Friets, Eric; Bieszczad, Jerry; Kynor, David; Norris, James; Davis, Brynmor; Allen, Lindsay; Chambers, Robert; Wolf, Jacob; Glisson, Courtenay; Herrell, S. Duke; Galloway, Robert L.
2013-03-01
Image guided surgery (IGS) has led to significant advances in surgical procedures and outcomes. Endoscopic IGS is hindered, however, by the lack of suitable intraoperative scanning technology for registration with preoperative tomographic image data. This paper describes implementation of an endoscopic laser range scanner (eLRS) system for accurate, intraoperative mapping of the kidney surface, registration of the measured kidney surface with preoperative tomographic images, and interactive image-based surgical guidance for subsurface lesion targeting. The eLRS comprises a standard stereo endoscope coupled to a steerable laser, which scans a laser fan beam across the kidney surface, and a high-speed color camera, which records the laser-illuminated pixel locations on the kidney. Through calibrated triangulation, a dense set of 3-D surface coordinates are determined. At maximum resolution, the eLRS acquires over 300,000 surface points in less than 15 seconds. Lower resolution scans of 27,500 points are acquired in one second. Measurement accuracy of the eLRS, determined through scanning of reference planar and spherical phantoms, is estimated to be 0.38 +/- 0.27 mm at a range of 2 to 6 cm. Registration of the scanned kidney surface with preoperative image data is achieved using a modified iterative closest point algorithm. Surgical guidance is provided through graphical overlay of the boundaries of subsurface lesions, vasculature, ducts, and other renal structures labeled in the CT or MR images, onto the eLRS camera image. Depth to these subsurface targets is also displayed. Proof of clinical feasibility has been established in an explanted perfused porcine kidney experiment.
Minimally invasive surgery for esophageal motility disorders.
Balaji, Nagammapudur S; Peters, Jeffrey H
2002-08-01
Laparoscopic Heller myotomy has emerged as an excellent primary treatment for patients with dysphagia secondary to achalasia. A laparoscopic rather than thoracoscopic approach has stood the test of time. An antireflux procedure combined with the myotomy is crucial to the maintenance of the antireflux barrier. Thoracoscopic long myotomy offers effective relief for spastic disorders of the esophagus. Endoscopic stapled diverticulotomy is a safe and effective procedure for Zenker's diverticulum and has potential advantages over the open approach.
Evaluation and Management of Caustic Injuries from Ingestion of Acid or Alkaline Substances
2014-01-01
Although the numbers have decreased compared with in the past, cases of patients who ingest caustic substances and visit the emergency room are not rare. However, well-summarized data about caustic injuries are insufficient. Therefore, in this article, I will discuss the etiologic causative agents, injury mechanism, and clinical characteristics, as well as the endoscopic evaluation of the degree of injury and proper management of the patient, in gastrointestinal caustic injury. PMID:25133115
Eichhorn, Klaus Wolfgang; Westphal, Ralf; Rilk, Markus; Last, Carsten; Bootz, Friedrich; Wahl, Friedrich; Jakob, Mark; Send, Thorsten
2017-10-01
Having one hand occupied with the endoscope is the major disadvantage for the surgeon when it comes to functional endoscopic sinus surgery (FESS). Only the other hand is free to use the surgical instruments. Tiredness or frequent instrument changes can thus lead to shaky endoscopic images. We collected the pose data (position and orientation) of the rigid 0° endoscope and all the instruments used in 16 FESS procedures with manual endoscope guidance as well as robot-assisted endoscope guidance. In combination with the DICOM CT data, we tracked the endoscope poses and workspaces using self-developed tracking markers. All surgeries were performed once with the robot and once with the surgeon holding the endoscope. Looking at the durations required, we observed a decrease in the operating time because one surgeon doing all the procedures and so a learning curve occurred what we expected. The visual inspection of the specimens showed no damages to any of the structures outside the paranasal sinuses. Robot-assisted endoscope guidance in sinus surgery is possible. Further CT data, however, are desirable for the surgical analysis of a tracker-based navigation within the anatomic borders. Our marker-based tracking of the endoscope as well as the instruments makes an automated endoscope guidance feasible. On the subjective side, we see that RASS brings a relief for the surgeon.
Minimal access surgery of pediatric inguinal hernias: a review.
Saranga Bharathi, Ramanathan; Arora, Manu; Baskaran, Vasudevan
2008-08-01
Inguinal hernia is a common problem among children, and herniotomy has been its standard of care. Laparoscopy, which gained a toehold initially in the management of pediatric inguinal hernia (PIH), has managed to steer world opinion against routine contralateral groin exploration by precise detection of contralateral patencies. Besides detection, its ability to repair simultaneously all forms of inguinal hernias (indirect, direct, combined, recurrent, and incarcerated) together with contralateral patencies has cemented its role as a viable alternative to conventional repair. Numerous minimally invasive techniques for addressing PIH have mushroomed in the past two decades. These techniques vary considerably in their approaches to the internal ring (intraperitoneal, extraperitoneal), use of ports (three, two, one), endoscopic instruments (two, one, or none), sutures (absorbable, nonabsorbable), and techniques of knotting (intracorporeal, extracorporeal). In addition to the surgeons' experience and the merits/limitations of individual techniques, it is the nature of the defect that should govern the choice of technique. The emerging techniques show a trend toward increasing use of extracorporeal knotting and diminishing use of working ports and endoscopic instruments. These favor wider adoption of minimal access surgery in addressing PIH by surgeons, irrespective of their laparoscopic skills and experience. Growing experience, wider adoption, decreasing complications, and increasing advantages favor emergence of minimal access surgery as the gold standard for the treatment of PIH in the future. This article comprehensively reviews the laparoscopic techniques of addressing PIH.
[Neoplasic colonic obstruction: resolution with self-expanding metallic stents].
Jury, Gastón; Amieva, Leandro; Dolan, Martín; Fagalde, Rafael López; Naiderman, Diego; Pastorino, Martín; Jury, Rubén
2014-03-01
The endoscopic placement of self-expanding metallic stents (SEMS) emerges as a therapeutic option for neoplastic colonic obstruction in two situations: as palliative treatment and as a bridge to surgery. The latter can avoid emergency surgery, thus decreasing the rate of ostomies and the mortality and morbidity associated with them. To evaluate the feasibility, safety and benefits of SEMS placement for the treatment of neoplastic colorectal obstruction. Between August 2008 and June 2012, we included in this prospective, longitudinal, descriptive and observational study all the patients suffering from colorectal neoplasia who were subjected to SEMS placement by the same group ofendoscopists. Nitinol SEMS were inserted under endoscopic vision and radioscopic control. Twenty seven SEMS were inserted in 27 patients, 61% of them were male and the average age was 70 years old. Symptoms of colonic suboclussion or obstruction were found in 92% of patients, 88% of the lesions were located in the left-side colon, 41% of cases were performed on an ambulatory basis and 65% of stenting was carried out for palliative purposes. The average time of hospitalization was 6,46 days. Technical and clinical success were 93% and 100%, respectively. Minor complications were observed in 11% of patients. Colonic stenting was followed by elective surgery within one month, by a laparoscopic technique in most cases. The placement of SEMS arises as a safe and effective alternative to palliative surgery or as a bridge to elective surgery.
Endoscopic root canal treatment.
Moshonov, Joshua; Michaeli, Eli; Nahlieli, Oded
2009-10-01
To describe an innovative endoscopic technique for root canal treatment. Root canal treatment was performed on 12 patients (15 teeth), using a newly developed endoscope (Sialotechnology), which combines an endoscope, irrigation, and a surgical microinstrument channel. Endoscopic root canal treatment of all 15 teeth was successful with complete resolution of all symptoms (6-month follow-up). The novel endoscope used in this study accurately identified all microstructures and simplified root canal treatment. The endoscope may be considered for use not only for preoperative observation and diagnosis but also for active endodontic treatment.
Endoscopic Rectus Abdominis and Prepubic Aponeurosis Repairs for Treatment of Athletic Pubalgia.
Matsuda, Dean K; Matsuda, Nicole A; Head, Rachel; Tivorsak, Tanya
2017-02-01
Review of the English orthopaedic literature reveals no prior report of endoscopic repair of rectus abdominis tears and/or prepubic aponeurosis detachment. This technical report describes endoscopic reattachment of an avulsed prepubic aponeurosis and endoscopic repair of a vertical rectus abdominis tear immediately after endoscopic pubic symphysectomy for coexistent recalcitrant osteitis pubis as a single-stage outpatient surgery. Endoscopic rectus abdominis repair and prepubic aponeurosis repair are feasible surgeries that complement endoscopic pubic symphysectomy for patients with concurrent osteitis pubis and expand the less invasive options for patients with athletic pubalgia.
Advanced Technologies in Safe and Efficient Operating Rooms
2009-02-01
parameters and sitting strategies to determine car seat design that is both comfortable and ergonomically sound.8 The study of ergonomics in the surgical...off stereo into a prototype endoscope and developed design concepts for visualization techniques based on principles of cognitive ergonomics ...results from simultaneous task performance—is typical of knowledge ascertained through ergonomic clinical research.6 Ergonomic theory, design , and
Gross, Andreas J; Herrmann, Thomas R W
2007-06-01
The developments of laser technology from the cradle of modern physics in 1900 by Planck to its latest medical boundaries is an exciting example of how basic physics finds its way into clinical practice. This article merits the protagonists and their contribution to the steps in this development. The competition between the different research groups finally led to the award of the Nobel Prize to Townes, Basov and Prokhorov in 1964 for the scientific basis on quantum electronics, which led to the construction of oscillators and amplifiers based on the laser-maser principle. Forty-three years after Einstein's first theories Maiman introduced the first ruby laser for commercial use. This marked the key step for the laser application and pioneered fruitful cooperations between basic and clinical science. The pioneers of lasers in clinical urology were Parsons in 1966 with studies in canine bladders and Mulvany 1968 with experiments in calculi fragmentation. The central technological component for the triumphal procession of lasers in urology is the endoscope. Therefore lasers are currently widely used, being the tool of choice in some areas, such as endoscopical lithotriptic stone treatment or endoluminal organ-preserving tumor ablation. Furthermore they show promising treatment alternatives for the treatment of benign prostate hyperplasia.
Real-time geometry-aware augmented reality in minimally invasive surgery.
Chen, Long; Tang, Wen; John, Nigel W
2017-10-01
The potential of augmented reality (AR) technology to assist minimally invasive surgery (MIS) lies in its computational performance and accuracy in dealing with challenging MIS scenes. Even with the latest hardware and software technologies, achieving both real-time and accurate augmented information overlay in MIS is still a formidable task. In this Letter, the authors present a novel real-time AR framework for MIS that achieves interactive geometric aware AR in endoscopic surgery with stereo views. The authors' framework tracks the movement of the endoscopic camera and simultaneously reconstructs a dense geometric mesh of the MIS scene. The movement of the camera is predicted by minimising the re-projection error to achieve a fast tracking performance, while the three-dimensional mesh is incrementally built by a dense zero mean normalised cross-correlation stereo-matching method to improve the accuracy of the surface reconstruction. The proposed system does not require any prior template or pre-operative scan and can infer the geometric information intra-operatively in real time. With the geometric information available, the proposed AR framework is able to interactively add annotations, localisation of tumours and vessels, and measurement labelling with greater precision and accuracy compared with the state-of-the-art approaches.
Analysis of the color rendition of flexible endoscopes
NASA Astrophysics Data System (ADS)
Murphy, Edward M.; Hegarty, Francis J.; McMahon, Barry P.; Boyle, Gerard
2003-03-01
Endoscopes are imaging devices routinely used for the diagnosis of disease within the human digestive tract. Light is transmitted into the body cavity via incoherent fibreoptic bundles and is controlled by a light feedback system. Fibreoptic endoscopes use coherent fibreoptic bundles to provide the clinician with an image. It is also possible to couple fibreoptic endoscopes to a clip-on video camera. Video endoscopes consist of a small CCD camera, which is inserted into gastrointestinal tract, and associated image processor to convert the signal to analogue RGB video signals. Images from both types of endoscope are displayed on standard video monitors. Diagnosis is dependent upon being able to determine changes in the structure and colour of tissues and biological fluids, and therefore is dependent upon the ability of the endoscope to reproduce the colour of these tissues and fluids with fidelity. This study investigates the colour reproduction of flexible optical and video endoscopes. Fibreoptic and video endoscopes alter image colour characteristics in different ways. The colour rendition of fibreoptic endoscopes was assessed by coupling them to a video camera and applying video colorimetric techniques. These techniques were then used on video endoscopes to assess how the colour rendition of video endoscopes compared with that of optical endoscopes. In both cases results were obtained at fixed illumination settings. Video endoscopes were then assessed with varying levels of illumination. Initial results show that at constant luminance endoscopy systems introduce non-linear shifts in colour. Techniques for examining how this colour shift varies with illumination intensity were developed and both methodology and results will be presented. We conclude that more rigorous quality assurance is required to reduce colour error and are developing calibration procedures applicable to medical endoscopes.
Selva, Dinesh
2008-01-01
Minimally invasive ″keyhole″ surgery performed using endoscopic visualization is increasing in popularity and is being used by almost all surgical subspecialties. Within ophthalmology, however, endoscopic surgery is not commonly performed and there is little literature on the use of the endoscope in orbital surgery. Transorbital use of the endoscope can greatly aid in visualizing orbital roof lesions and minimizing the need for bone removal. The endoscope is also useful during decompression procedures and as a teaching aid to train orbital surgeons. In this article, we review the history of endoscopic orbital surgery and provide an overview of the technique and describe situations where the endoscope can act as a useful adjunct to orbital surgery. PMID:18158397
Lee, J H; Kim, B K; Seol, D C; Byun, S J; Park, K H; Sung, I K; Park, H S; Shim, C S
2013-06-01
Nonvariceal upper gastrointestinal (UGI) bleeding recurs after appropriate endoscopic therapy in 10 % - 15 % of cases. The mortality rate can be as high as 25 % when bleeding recurs, but there is no consensus about the best modality for endoscopic re-treatment. The aim of this study was to evaluate clipping and detachable snaring (CDS) for rescue endoscopic control of nonvariceal UGI hemorrhage. We report a case series of seven patients from a Korean tertiary center who underwent endoscopic hemostasis using the combined method of detachable snares with hemoclips. The success rate of endoscopic hemostasis with CDS was 86 %: six of the seven patients who had experienced primary endoscopic treatment failure or recurrent bleeding after endoscopic hemostasis were treated successfully. In conclusion, rescue endoscopic bleeding control by means of CDS is an option for controlling nonvariceal UGI bleeding when no other method of endoscopic treatment for recurrent bleeding and primary hemostatic failure is possible. © Georg Thieme Verlag KG Stuttgart · New York.
Hanaoka, N; Uedo, N; Ishihara, R; Higashino, K; Takeuchi, Y; Inoue, T; Chatani, R; Hanafusa, M; Tsujii, Y; Kanzaki, H; Kawada, N; Iishi, H; Tatsuta, M; Tomita, Y; Miyashiro, I; Yano, M
2010-12-01
Perforation is a major complication of endoscopic submucosal dissection (ESD) for early gastric cancer (EGC). However, there have been no reports on delayed perforation after ESD for EGC. We aimed to elucidate the incidence and outcomes of delayed perforation after ESD. Clinical courses in 1159 consecutive patients with 1329 EGCs who underwent ESD were investigated. Delayed perforation occurred in six patients (0.45 %). All these patients had complete en bloc resection without intraoperative perforation during ESD. Five of six perforations were located in the upper third of the stomach, while one lesion was found in the middle third. Symptoms of peritoneal irritation with rebound tenderness presented within 24 h after ESD in all cases. One patient did not require surgery because the symptoms were localized, and recovered with conservative antibiotic therapy by nasogastric tube placement. The remaining five patients required emergency surgery. There was no mortality in this case series. © Georg Thieme Verlag KG Stuttgart · New York.
A visual graphic/haptic rendering model for hysteroscopic procedures.
Lim, Fabian; Brown, Ian; McColl, Ryan; Seligman, Cory; Alsaraira, Amer
2006-03-01
Hysteroscopy is an extensively popular option in evaluating and treating women with infertility. The procedure utilises an endoscope, inserted through the vagina and cervix to examine the intra-uterine cavity via a monitor. The difficulty of hysteroscopy from the surgeon's perspective is the visual spatial perception of interpreting 3D images on a 2D monitor, and the associated psychomotor skills in overcoming the fulcrum-effect. Despite the widespread use of this procedure, current qualified hysteroscopy surgeons have not been trained the fundamentals through an organised curriculum. The emergence of virtual reality as an educational tool for this procedure, and for other endoscopic procedures, has undoubtedly raised interests. The ultimate objective is for the inclusion of virtual reality training as a mandatory component for gynaecologic endoscopy training. Part of this process involves the design of a simulator, encompassing the technical difficulties and complications associated with the procedure. The proposed research examines fundamental hysteroscopy factors, current training and accreditation, and proposes a hysteroscopic simulator design that is suitable for educating and training.
Endoscopic management of pancreatic fistula after pancreatic and other abdominal surgery.
Le Moine, Olivier; Matos, Celso; Closset, Jean; Devière, Jacques
2004-10-01
Post-operative pancreatic fistulae represent a challenge for all the actors in gastroenterology: for surgeons, because they want to prevent and treat conservatively this complication since re-operation is associated with high morbidity and mortality rates; for radiologists, because they have to provide the best staging and informations without any additional risk; and for endoscopists, because endoluminal treatment is emerging as a safe and effective procedure provided it is performed in highly experienced tertiary centres in the setting of a multidisciplinary approach. Herein, we review the definitions, the causes, the staging and the possible options to prevent or treat post-operative pancreatic fistulae. Special attention is paid to the endoscopic management of this complication: including the relief of ductal obstructions, the stenting of leakages and the drainage of bulging or non-bulging fluid collections. Practical problems and issues are clearly outlined as well as the need for future improvements in staging and management of the patients having such complications.
Molecular Imaging: Current Status and Emerging Strategies
Pysz, Marybeth A.; Gambhir, Sanjiv S.; Willmann, Jürgen K.
2011-01-01
In vivo molecular imaging has a great potential to impact medicine by detecting diseases in early stages (screening), identifying extent of disease, selecting disease- and patient-specific therapeutic treatment (personalized medicine), applying a directed or targeted therapy, and measuring molecular-specific effects of treatment. Current clinical molecular imaging approaches primarily use PET- or SPECT-based techniques. In ongoing preclinical research novel molecular targets of different diseases are identified and, sophisticated and multifunctional contrast agents for imaging these molecular targets are developed along with new technologies and instrumentation for multimodality molecular imaging. Contrast-enhanced molecular ultrasound with molecularly-targeted contrast microbubbles is explored as a clinically translatable molecular imaging strategy for screening, diagnosing, and monitoring diseases at the molecular level. Optical imaging with fluorescent molecular probes and ultrasound imaging with molecularly-targeted microbubbles are attractive strategies since they provide real-time imaging, are relatively inexpensive, produce images with high spatial resolution, and do not involve exposure to ionizing irradiation. Raman spectroscopy/microscopy has emerged as a molecular optical imaging strategy for ultrasensitive detection of multiple biomolecules/biochemicals with both in vivo and ex vivo versatility. Photoacoustic imaging is a hybrid of optical and ultrasound modalities involving optically-excitable molecularly-targeted contrast agents and quantitative detection of resulting oscillatory contrast agent movement with ultrasound. Current preclinical findings and advances in instrumentation such as endoscopes and microcatheters suggest that these molecular imaging modalities have numerous clinical applications and will be translated into clinical use in the near future. PMID:20541650
Raczynski, Susanne; Teich, Niels; Borte, Gudrun; Wittenburg, Henning; Mössner, Joachim; Caca, Karel
2006-09-01
Endoscopic drainage of pancreatic acute and chronic pseudocysts and pancreatic necrosectomy have been shown to be beneficial for critically ill patients, with complete endoscopic resolution rates of around 80%. Our purpose was to describe an improved endoscopic technique used to treat pancreatic necrosis. Case report. University hospital. Two patients with large retroperitoneal necroses were treated with percutaneous transgastric retroperitoneal flushing tubes and a percutaneous transgastric jejunal feeding tube by standard percutaneous endoscopic gastrostomy access in addition to endoscopic necrosectomy. Intensive percutaneous transgastric flushing in combination with percutaneous normocaloric enteral nutrition and repeated endoscopic necrosectomy led to excellent outcomes in both patients. Small number of patients. The "double percutaneous endoscopic gastrostomy" approach for simultaneous transgastric drainage and normocaloric enteral nutrition in severe cases of pancreatic necroses is safe and effective. It could be a promising improvement to endoscopic transgastric treatment options in necrotizing pancreatitis.
Trulson, Alexander; Küper, Markus Alexander; Trulson, Inga Maria; Minarski, Christian; Grünwald, Leonard; Hirt, Bernhard; Stöckle, Ulrich; Stuby, Fabian
2018-06-14
Dislocated pelvic fractures which require surgical repair are usually operated on via open surgery. Approach-related morbidity is reported with a frequency of up to 30%. The aim of this anatomical study was to prove the feasibility of endoscopic visualisation of the relevant anatomical structures in pelvic surgery and to perform completely endoscopic plate osteosynthesis of the acetabulum with available standard laparoscopic instruments. In four human cadavers, we established an endoscopic preparation of the complete pelvic ring, from the symphysis to the iliosacral joint, including the quadrilateral plate and the sciatic nerve, and performed endoscopic plate osteosynthesis along the iliopectineal line. The endoscopic preparation of the complete pelvic ring and the quadrilateral plate was demonstrated step-by-step, followed by completely endoscopic plate osteosynthesis along the pelvic brim. Endoscopic, radiographic, and schematic pictures are used to illustrate the technique. The completely endoscopic preparation of the pelvic brim and the quadrilateral plate is feasible with available standard laparoscopic instruments. Moreover, plate osteosynthesis could be performed endoscopically. Further research on reduction techniques is necessary when planning to implement this technique into a clinical scenario. Georg Thieme Verlag KG Stuttgart · New York.
Sphincterotomy in patients with gallstones, elevated LFTs and a normal CBD on ERCP.
Siddique, Iqbal; Mohan, Krishna; Khajah, Abdulkareem; Hasan, Fuad; Memon, Anjum; Kalaoui, Maher; al-Shamali, Mohammad; Patty, Istvan; al-Nakib, Basil
2003-01-01
To determine whether an endoscopic sphincterotomy affects outcome in patients with symptomatic gallstones, elevated liver function tests and a normal common bile duct on endoscopic retrograde cholangiopancreatogram. A total of 163 patients with symptomatic gallstones and elevated liver function tests, and found to have a normal common bile duct on endoscopic retrograde cholangiopancreatogram were included in the study. Endoscopic sphincterotomy was performed in 78 (47.8%) patients, while 85 (52.1%) patients did not have an endoscopic sphincterotomy. The two groups were compared for detection of small unseen common bile duct stones/debris, endoscopic retrograde cholangiopancreatogram related complications, and biliary complications after cholecystectomy. Small common bile duct stones/debris were recovered in 11/43 (25.5%) patients who had instrumentation of the common bile duct performed after endoscopic sphincterotomy. Common bile duct instrumentation was not performed in any of the patients without endoscopic sphincterotomy. No patient had any biliary complication after cholecystectomy, both in the immediate postoperative period and on a follow-up of 37.5 +/- 13.6 months (range 17-66). Endoscopic retrograde cholangiopancreatogram related complications occurred in 8 patients who had an endoscopic sphincterotomy and in 2 without endoscopic sphincterotomy (p < 0.05). Performing an endoscopic sphincterotomy in these patients increases the detection of small unseen common bile duct stones/debris without changing the clinical outcome after cholecystectomy. It also increases the endoscopic retrograde cholangiopancreatogram related complication rate, and therefore may not be necessary.
Gastric full-thickness suturing during EMR and for treatment of gastric-wall defects (with video).
von Renteln, Daniel; Schmidt, Arthur; Riecken, Bettina; Caca, Karel
2008-04-01
The endoscopic full-thickness Plicator device was initially developed to provide an endoscopic treatment option for patients with GERD. Because the endoscopic full-thickness Plicator enables rapid and easy placement of transmural sutures, comparable with surgical sutures, we used the Plicator device for endoscopic treatment or prevention of GI-wall defects. To describe the outcomes and complications of endoscopic full-thickness suturing during EMR and for the treatment of gastric-wall defects. A report of 4 cases treated with the endoscopic full-thickness suturing between June 2006 and April 2007. A large tertiary-referral center. Four subjects received endoscopic full-thickness suturing. The subjects were women, with a mean age of 67 years. Of the 4 subjects, 3 received endoscopic full-thickness suturing during or after an EMR. One subject received endoscopic full-thickness suturing for treatment of a fistula. Primary outcome measurements were clinical procedural success and procedure-related adverse events. The mean time for endoscopic full-thickness suturing was 15 minutes. In all cases, GI-wall patency was restored or ensured, and no procedure-related complications occurred. All subjects responded well to endoscopic full-thickness suturing. The resection of one GI stromal tumor was incomplete. Because of the Plicator's 60F distal-end diameter, endoscopic full-thickness suturing could only be performed with the patient under midazolam and propofol sedation. The durable Plicator suture might compromise the endoscopic follow-up after EMR. The endoscopic full-thickness Plicator permits rapid and easy placement of transmural sutures and seems to be a safe and effective alternative to surgical intervention to restore GI-wall defects or to ensure GI-wall patency during EMR procedures.
Ultrahigh speed en face OCT capsule for endoscopic imaging
Liang, Kaicheng; Traverso, Giovanni; Lee, Hsiang-Chieh; Ahsen, Osman Oguz; Wang, Zhao; Potsaid, Benjamin; Giacomelli, Michael; Jayaraman, Vijaysekhar; Barman, Ross; Cable, Alex; Mashimo, Hiroshi; Langer, Robert; Fujimoto, James G.
2015-01-01
Depth resolved and en face OCT visualization in vivo may have important clinical applications in endoscopy. We demonstrate a high speed, two-dimensional (2D) distal scanning capsule with a micromotor for fast rotary scanning and a pneumatic actuator for precision longitudinal scanning. Longitudinal position measurement and image registration were performed by optical tracking of the pneumatic scanner. The 2D scanning device enables high resolution imaging over a small field of view and is suitable for OCT as well as other scanning microscopies. Large field of view imaging for screening or surveillance applications can also be achieved by proximally pulling back or advancing the capsule while scanning the distal high-speed micromotor. Circumferential en face OCT was demonstrated in living swine at 250 Hz frame rate and 1 MHz A-scan rate using a MEMS tunable VCSEL light source at 1300 nm. Cross-sectional and en face OCT views of the upper and lower gastrointestinal tract were generated with precision distal pneumatic longitudinal actuation as well as proximal manual longitudinal actuation. These devices could enable clinical studies either as an adjunct to endoscopy, attached to an endoscope, or as a swallowed tethered capsule for non-endoscopic imaging without sedation. The combination of ultrahigh speed imaging and distal scanning capsule technology could enable both screening and surveillance applications. PMID:25909001
Ultrahigh speed en face OCT capsule for endoscopic imaging.
Liang, Kaicheng; Traverso, Giovanni; Lee, Hsiang-Chieh; Ahsen, Osman Oguz; Wang, Zhao; Potsaid, Benjamin; Giacomelli, Michael; Jayaraman, Vijaysekhar; Barman, Ross; Cable, Alex; Mashimo, Hiroshi; Langer, Robert; Fujimoto, James G
2015-04-01
Depth resolved and en face OCT visualization in vivo may have important clinical applications in endoscopy. We demonstrate a high speed, two-dimensional (2D) distal scanning capsule with a micromotor for fast rotary scanning and a pneumatic actuator for precision longitudinal scanning. Longitudinal position measurement and image registration were performed by optical tracking of the pneumatic scanner. The 2D scanning device enables high resolution imaging over a small field of view and is suitable for OCT as well as other scanning microscopies. Large field of view imaging for screening or surveillance applications can also be achieved by proximally pulling back or advancing the capsule while scanning the distal high-speed micromotor. Circumferential en face OCT was demonstrated in living swine at 250 Hz frame rate and 1 MHz A-scan rate using a MEMS tunable VCSEL light source at 1300 nm. Cross-sectional and en face OCT views of the upper and lower gastrointestinal tract were generated with precision distal pneumatic longitudinal actuation as well as proximal manual longitudinal actuation. These devices could enable clinical studies either as an adjunct to endoscopy, attached to an endoscope, or as a swallowed tethered capsule for non-endoscopic imaging without sedation. The combination of ultrahigh speed imaging and distal scanning capsule technology could enable both screening and surveillance applications.
Barrett's oesophagus: epidemiology, diagnosis and clinical management.
Whiteman, David C; Kendall, Bradley J
2016-10-03
Barrett's oesophagus is a condition characterised by partial replacement of the normal squamous epithelium of the lower oesophagus by a metaplastic columnar epithelium containing goblet cells (intestinal metaplasia). Barrett's oesophagus is important clinically because those afflicted are predisposed to oesophageal adenocarcinoma. Prevalence surveys suggest that up to 2% of the population may be affected; most will be unaware of their diagnosis. Risk factors include age, male sex, gastro-oesophageal acid reflux, central obesity and smoking. Helicobacter pylori infection confers a reduced risk of Barrett's oesophagus. Risks of cancer progression are lower than originally reported and are now estimated at 1-3 per 1000 patient-years for patients with non-dysplastic Barrett's oesophagus. Progression rates are higher for patients with long segment (≥ 3 cm) and dysplastic Barrett's oesophagus. Australian guidelines have been developed to aid practitioners in managing patients with Barrett's oesophagus and early oesophageal adenocarcinoma. While generalised population screening for Barrett's oesophagus is not recommended, endoscopic surveillance of patients with confirmed Barrett's oesophagus is recommended, with surveillance intervals dependent on segment length and presence of dysplasia. New techniques such as endoscopic mucosal resection and endoscopic radiofrequency ablation are now available to treat patients with dysplasia and early oesophageal adenocarcinoma. New screening and surveillance technologies are currently under investigation; these may prove cost-effective in identifying and managing patients in the community.
75 FR 18484 - Emerging Technology and Research Advisory Committee; Notice of Open Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-12
... Emerging Technologies Analysis. 2. ETRAC Panel on Emerging Technologies. 3. History of the Laser. 4... DEPARTMENT OF COMMERCE Bureau of Industry and Security Emerging Technology and Research Advisory Committee; Notice of Open Meeting The Emerging Technology and Research Advisory Committee (ETRAC) [[Page...
Method for radiometric calibration of an endoscope's camera and light source
NASA Astrophysics Data System (ADS)
Rai, Lav; Higgins, William E.
2008-03-01
An endoscope is a commonly used instrument for performing minimally invasive visual examination of the tissues inside the body. A physician uses the endoscopic video images to identify tissue abnormalities. The images, however, are highly dependent on the optical properties of the endoscope and its orientation and location with respect to the tissue structure. The analysis of endoscopic video images is, therefore, purely subjective. Studies suggest that the fusion of endoscopic video images (providing color and texture information) with virtual endoscopic views (providing structural information) can be useful for assessing various pathologies for several applications: (1) surgical simulation, training, and pedagogy; (2) the creation of a database for pathologies; and (3) the building of patient-specific models. Such fusion requires both geometric and radiometric alignment of endoscopic video images in the texture space. Inconsistent estimates of texture/color of the tissue surface result in seams when multiple endoscopic video images are combined together. This paper (1) identifies the endoscope-dependent variables to be calibrated for objective and consistent estimation of surface texture/color and (2) presents an integrated set of methods to measure them. Results show that the calibration method can be successfully used to estimate objective color/texture values for simple planar scenes, whereas uncalibrated endoscopes performed very poorly for the same tests.
Friedrich, D T; Sommer, F; Scheithauer, M O; Greve, J; Hoffmann, T K; Schuler, P J
2017-12-01
Objective Advanced transnasal sinus and skull base surgery remains a challenging discipline for head and neck surgeons. Restricted access and space for instrumentation can impede advanced interventions. Thus, we present the combination of an innovative robotic endoscope guidance system and a specific endoscope with adjustable viewing angle to facilitate transnasal surgery in a human cadaver model. Materials and Methods The applicability of the robotic endoscope guidance system with custom foot pedal controller was tested for advanced transnasal surgery on a fresh frozen human cadaver head. Visualization was enabled using a commercially available endoscope with adjustable viewing angle (15-90 degrees). Results Visualization and instrumentation of all paranasal sinuses, including the anterior and middle skull base, were feasible with the presented setup. Controlling the robotic endoscope guidance system was effectively precise, and the adjustable endoscope lens extended the view in the surgical field without the common change of fixed viewing angle endoscopes. Conclusion The combination of a robotic endoscope guidance system and an advanced endoscope with adjustable viewing angle enables bimanual surgery in transnasal interventions of the paranasal sinuses and the anterior skull base in a human cadaver model. The adjustable lens allows for the abandonment of fixed-angle endoscopes, saving time and resources, without reducing the quality of imaging.
A case of gastric perforation caused by chestnut bezoars.
Okagawa, Yutaka; Takada, Kohichi; Arihara, Yohei; Kato, Junji
A 65-year-old man was admitted under emergency to our hospital because of abdominal pain. His current medication history did not include steroids or nonsteroidal antiinflammatory drugs. He had taken an eradication agent for Helicobacter pylori, and his serum was negative for H. pylori IgG antibody. Abdominal computed tomography indicated gastric perforation;therefore, emergency surgery was performed. Two weeks later, esophagogastroduodenoscopy revealed a gastric ulcer on the lesser curvature of the gastric angle and bezoars. The gastric perforation was thought to be caused by the bezoars. The bezoars were successfully treated with endoscopic therapy using Coca-Cola ® . The bezoars included over 98% tannin, and the patient had frequently consumed chestnuts. We thus diagnosed a rare case of gastric perforation caused by chestnut bezoars.
Luo, Xiongbiao; Jayarathne, Uditha L; McLeod, A Jonathan; Mori, Kensaku
2014-01-01
Endoscopic navigation generally integrates different modalities of sensory information in order to continuously locate an endoscope relative to suspicious tissues in the body during interventions. Current electromagnetic tracking techniques for endoscopic navigation have limited accuracy due to tissue deformation and magnetic field distortion. To avoid these limitations and improve the endoscopic localization accuracy, this paper proposes a new endoscopic navigation framework that uses an optical mouse sensor to measure the endoscope movements along its viewing direction. We then enhance the differential evolution algorithm by modifying its mutation operation. Based on the enhanced differential evolution method, these movement measurements and image structural patches in endoscopic videos are fused to accurately determine the endoscope position. An evaluation on a dynamic phantom demonstrated that our method provides a more accurate navigation framework. Compared to state-of-the-art methods, it improved the navigation accuracy from 2.4 to 1.6 mm and reduced the processing time from 2.8 to 0.9 seconds.
[Current Status of Endoscopic Resection of Early Gastric Cancer in Korea].
Jung, Hwoon Yong
2017-09-25
Endoscopic resection (Endoscopic mucosal resection [EMR] and endoscopic submucosal dissection [ESD]) is already established as a first-line treatment modality for selected early gastric cancer (EGC). In Korea, the number of endoscopic resection of EGC was explosively increased because of a National Cancer Screening Program and development of devices and techniques. There were many reports on the short-term and long-term outcomes after endoscopic resection in patients with EGC. Long-term outcome in terms of recurrence and death is excellent in both absolute and selected expanded criteria. Furthermore, endoscopic resection might be positioned as primary treatment modality replacing surgical gastrectomy. To obtain these results, selection of patients, perfect en bloc procedure, thorough pathological examination of resected specimen, accurate interpretation of whole process of endoscopic resection, and rational strategy for follow-up is necessary.
Cho, Yu Kyung; Moon, Jeong Seop; Han, Dong Su; Lee, Yong Chan; Kim, Yeol; Park, Bo Young; Chung, Il-Kwun; Kim, Jin-Oh; Im, Jong Pil; Cha, Jae Myung; Kim, Hyun Gun; Lee, Sang Kil; Lee, Hang Lak; Jang, Jae Young; Kim, Eun Sun; Jung, Yunho; Moon, Chang Mo
2016-11-01
In Korea, the nationwide gastric cancer screening program recommends biennial screening for individuals aged 40 years or older by way of either an upper gastrointestinal series or endoscopy. The national endoscopic quality assessment (QA) program began recommending endoscopy in medical institutions in 2009. We aimed to assess the effect, burden, and cost of the QA program from the viewpoint of medical institutions. We surveyed the staff of institutional endoscopic units via e-mail. Staff members from 67 institutions replied. Most doctors were endoscopic specialists. They responded as to whether the QA program raised awareness for endoscopic quality (93%) or improved endoscopic practice (40%). The percentages of responders who reported improvements in the diagnosis of gastric cancer, the qualifications of endoscopists, the quality of facilities and equipment, endoscopic procedure, and endoscopic reprocessing were 69%, 60%, 66%, 82%, and 75%, respectively. Regarding reprocessing, many staff members reported that they had bought new automated endoscopic preprocessors (3%), used more disinfectants (34%), washed endoscopes longer (28%), reduced the number of endoscopies performed to adhere to reprocessing guidelines (9%), and created their own quality education programs (59%). Many responders said they felt that QA was associated with some degree of burden (48%), especially financial burden caused by purchasing new equipment. Reasonable quality standards (45%) and incentives (38%) were considered important to the success of the QA program. Endoscopic quality has improved after 5 years of the mandatory endoscopic QA program.
Chellali, Amine; Schwaitzberg, Steven D.; Jones, Daniel B.; Romanelli, John; Miller, Amie; Rattner, David; Roberts, Kurt E.; Cao, Caroline G.L.
2014-01-01
Background NOTES is an emerging technique for performing surgical procedures, such as cholecystectomy. Debate about its real benefit over the traditional laparoscopic technique is on-going. There have been several clinical studies comparing NOTES to conventional laparoscopic surgery. However, no work has been done to compare these techniques from a Human Factors perspective. This study presents a systematic analysis describing and comparing different existing NOTES methods to laparoscopic cholecystectomy. Methods Videos of endoscopic/laparoscopic views from fifteen live cholecystectomies were analyzed to conduct a detailed task analysis of the NOTES technique. A hierarchical task analysis of laparoscopic cholecystectomy and several hybrid transvaginal NOTES cholecystectomies was performed and validated by expert surgeons. To identify similarities and differences between these techniques, their hierarchical decomposition trees were compared. Finally, a timeline analysis was conducted to compare the steps and substeps. Results At least three variations of the NOTES technique were used for cholecystectomy. Differences between the observed techniques at the substep level of hierarchy and on the instruments being used were found. The timeline analysis showed an increase in time to perform some surgical steps and substeps in NOTES compared to laparoscopic cholecystectomy. Conclusion As pure NOTES is extremely difficult given the current state of development in instrumentation design, most surgeons utilize different hybrid methods – combination of endoscopic and laparoscopic instruments/optics. Results of our hierarchical task analysis yielded an identification of three different hybrid methods to perform cholecystectomy with significant variability amongst them. The varying degrees to which laparoscopic instruments are utilized to assist in NOTES methods appear to introduce different technical issues and additional tasks leading to an increase in the surgical time. The NOTES continuum of invasiveness is proposed here as a classification scheme for these methods, which was used to construct a clear roadmap for training and technology development. PMID:24902811
Building an endoscopic ear surgery program.
Golub, Justin S
2016-10-01
This article discusses background, operative details, and outcomes of endoscopic ear surgery. This information will be helpful for those establishing a new program. Endoscopic ear surgery is growing in popularity. The ideal benefit is in totally transcanal access that would otherwise require a larger incision. The endoscope carries a number of advantages over the microscope, as well as some disadvantages. Several key maneuvers can minimize disadvantages. There is a paucity of studies directly comparing outcomes between endoscopic and microscopic approaches for the same procedure. The endoscope is gaining acceptance as a tool for treating otologic diseases. For interested surgeons, this article can help bridge the transition from microscopic to totally transcanal endoscopic ear surgery for appropriate disease.
Nemati, Shahram; Teimourian, Shahram
2017-01-01
Inflammatory bowel disease (IBD) is the consequence of an aberrant hemostasis of the immune cells at the gut mucosal border. Based on clinical manifestation, laboratory tests, radiological studies, endoscopic and histological features, this disease is divided into three main types including Crohn’s disease (CD), Ulcerative colitis (UC), and IBDunclassified (IBD-U). IBD is frequently presented in adults, but about 20% of IBD cases are diagnosed during childhood called pediatric IBD (PIBD). Some patients in the latter group emerge the first symptoms during infancy or under 5 years of age named infantile and very early onset IBD (VEO-IBD), respectively. These subtypes make a small fraction of PIBD, but they have exclusive phenotypic and genetic characteristics such that they are accompanied by severe disease course and resistance to conventional therapy. In this context, understanding the underlying molecular pathology opens a promising field for individualized and effective treatment. Here, we describe current hypotheses on IBD pathophysiology then explain the new idea about genetic screening technology as a good potential approach to identify the causal variants early in the disease manifestation, which is especially important for the fast and accurate treatment of VEO-IBD. PMID:28638582
Security and privacy issues in wireless sensor networks for healthcare applications.
Al Ameen, Moshaddique; Liu, Jingwei; Kwak, Kyungsup
2012-02-01
The use of wireless sensor networks (WSN) in healthcare applications is growing in a fast pace. Numerous applications such as heart rate monitor, blood pressure monitor and endoscopic capsule are already in use. To address the growing use of sensor technology in this area, a new field known as wireless body area networks (WBAN or simply BAN) has emerged. As most devices and their applications are wireless in nature, security and privacy concerns are among major areas of concern. Due to direct involvement of humans also increases the sensitivity. Whether the data gathered from patients or individuals are obtained with the consent of the person or without it due to the need by the system, misuse or privacy concerns may restrict people from taking advantage of the full benefits from the system. People may not see these devices safe for daily use. There may also possibility of serious social unrest due to the fear that such devices may be used for monitoring and tracking individuals by government agencies or other private organizations. In this paper we discuss these issues and analyze in detail the problems and their possible measures.
Inflammatory bowel disease imaging: Current practice and future directions.
Kilcoyne, Aoife; Kaplan, Jess L; Gee, Michael S
2016-01-21
The purpose of this paper is to evaluate the role of imaging in inflammatory bowel disease (IBD), including detection of extraluminal complications and extraintestinal manifestations of IBD, assessment of disease activity and treatment response, and discrimination of inflammatory from fibrotic strictures. IBD is a chronic idiopathic disease affecting the gastrointestinal tract that is comprised of two separate, but related intestinal disorders; Crohn's disease and ulcerative colitis. The paper discusses, in detail the pros and cons of the different IBD imaging modalities that need to be considered in order to optimize the imaging and clinical evaluation of patients with IBD. Historically, IBD evaluation of the bowel has included imaging to assess the portions of the small bowel that are inaccessible to optical endoscopic visualization. This traditionally was performed using barium fluoroscopic techniques; however, cross-sectional imaging techniques (computed tomography and magnetic resonance imaging) are being increasingly utilized for IBD evaluation because they can simultaneously assess mural and extramural IBD manifestations. Recent advances in imaging technology, that continue to improve the ability of imaging to noninvasively follow disease activity and treatment response, are also discussed. This review article summarizes the current imaging approach in inflammatory bowel disease as well as the role of emerging imaging modalities.
Lasers in clinical urology: state of the art and new horizons.
Marks, Andrew J; Teichman, Joel M H
2007-06-01
We present an overview of current and emerging lasers for Urology. We begin with an overview of the Holmium:YAG laser. The Ho:YAG laser is the gold standard lithotripsy modality for endoscopic lithotripsy, and compares favorably to standard electrocautery transurethral resection of the prostate for benign prostatic hyperplasia (BPH). Available laser technologies currently being studied include the frequency doubled double-pulse Nd:Yag (FREDDY) and high-powered potassium-titanyl-phosphate (KTP) lasers. The FREDDY laser presents an affordable and safe option for intracorporeal lithotripsy, but it does not fragment all stone compositions, and does not have soft tissue applications. The high power KTP laser shows promise in the ablative treatment of BPH. Initial experiments with the Erbium:YAG laser show it has improved efficiency of lithotripsy and more precise ablative and incisional properties compared to Ho:YAG, but the lack of adequate optical fibers limits its use in Urology. Thulium:YAG fiber lasers have also demonstrated tissue ablative and incision properties comparable to Ho:YAG. Lastly, compact size, portability, and low maintenance schedules of fiber lasers may allow them to shape the way lasers are used by urologists in the future.
NASA Astrophysics Data System (ADS)
Duan, Xiyu; Li, Haijun; Zhou, Juan; Zhou, Quan; Oldham, Kenn R.; Wang, Thomas D.
2016-11-01
Confocal endomicroscopy is an emerging imaging technology that has recently been introduced into the clinic to instantaneously collect “optical biopsies” in vivo with histology-like quality. Here, we demonstrate a fast scanner located in the distal end of a side-viewing instrument using a compact lens assembly with numerical aperture of 0.5 to achieve a working distance of 100 μm and field-of-view of 300 × 400 μm2. The microelectromechanical systems (MEMS) mirror was designed based on the principle of parametric resonance and images at 5 frames per second. The instrument has a 4.2 mm outer diameter and 3 cm rigid length, and can pass through the biopsy channel of a medical endoscope. We achieved real time optical sections of NIR fluorescence with 0.87 μm lateral resolution, and were able to visualize in vivo binding of a Cy5.5-labeled peptide specific for EGFR to the cell surface of pre-cancerous colonocytes within the epithelium of dysplastic crypts in mouse colon. By performing targeted imaging with endomicroscopy, we can visualize molecular expression patterns in vivo that provide a biological basis for disease detection.
Endoscopic neurosurgery "around the corner" with a rigid endoscope. Technical note.
Hopf, N J
1999-03-01
Endoscopically "working around the corner" is presently restricted to the use of flexible endoscopes or an endoscope-assisted microneurosurgical (EAM) technique. In order to overcome the limitations of these solutions, endoscopic equipment and techniques were developed for "working around the corner" with rigid endoscopes. A steering insert with a 5 French working channel is capable of steering instruments around the corner by actively bending the guiding track and consecutively the instrument. A special fixation device enables strict axial rotation of the endoscope in the operating field. Endoscopic procedures "around the corner", including aqueductal stenting, pellucidotomy, third ventriculostomy and biopsy were performed in human cadavers. Special features of the used pediatric neuroendoscope system, i.e., reliable fixation, axial rotation, and controlled steering of instruments, increase the safety and reduce the surgical traumatization in selected cases, such as obstructive hydrocephalus due to a mass lesion in the posterior third ventricle, since endoscopic third ventriculostomy and biopsy can be performed through the same burr hole trephination. Limitations of this technique are given by the size of the foramen of Monro and the height of the third ventricle as well as by the bending angle of the instruments (40-50 degrees).
A beam-splitter-type 3-D endoscope for front view and front-diagonal view images.
Kamiuchi, Hiroki; Masamune, Ken; Kuwana, Kenta; Dohi, Takeyoshi; Kim, Keri; Yamashita, Hiromasa; Chiba, Toshio
2013-01-01
In endoscopic surgery, surgeons must manipulate an endoscope inside the body cavity to observe a large field-of-view while estimating the distance between surgical instruments and the affected area by reference to the size or motion of the surgical instruments in 2-D endoscopic images on a monitor. Therefore, there is a risk of the endoscope or surgical instruments physically damaging body tissues. To overcome this problem, we developed a Ø7- mm 3-D endoscope that can switch between providing front and front-diagonal view 3-D images by simply rotating its sleeves. This 3-D endoscope consists of a conventional 3-D endoscope and an outer and inner sleeve with a beam splitter and polarization plates. The beam splitter was used for visualizing both the front and front-diagonal view and was set at 25° to the outer sleeve's distal end in order to eliminate a blind spot common to both views. Polarization plates were used to avoid overlap of the two views. We measured signal-to-noise ratio (SNR), sharpness, chromatic aberration (CA), and viewing angle of this 3-D endoscope and evaluated its feasibility in vivo. Compared to the conventional 3-D endoscope, SNR and sharpness of this 3-D endoscope decreased by 20 and 7 %, respectively. No significant difference was found in CA. The viewing angle for both the front and front-diagonal views was about 50°. In the in vivo experiment, this 3-D endoscope can provide clear 3-D images of both views by simply rotating its inner sleeve. The developed 3-D endoscope can provide the front and front-diagonal view by simply rotating the inner sleeve, therefore the risk of damage to fragile body tissues can be significantly decreased.
NASA Astrophysics Data System (ADS)
Dong, Jing; Gora, Michalina J.; Beaulieu-Ouellet, Emilie; Queneherve, Lucille H.; Grant, Catriona N.; Rosenberg, Mireille; Nishioka, Norman S.; Fasano, Alessio; Tearney, Guillermo J.
2017-02-01
Celiac disease (CD) affects around 1% of the global population and can cause serious long-term symptoms including malnutrition, fatigue, and diarrhea, amongst others. Despite this, it is often left undiagnosed. Currently, a tissue diagnosis of CD is made by random endoscopic biopsy of the duodenum to confirm the existence of microscopic morphologic alterations in the intestinal mucosa. However, duodenal endoscopic biopsy is problematic because the morphological changes can be focal and endoscopic biopsy is plagued by sampling error. Additionally, tissue artifacts can also an issue because cuts in the transverse plane can make duodenal villi appear artifactually shortened and can bias the assessment of intraepithelial inflammation. Moreover, endoscopic biopsy is costly and poorly tolerated as the patient needs to be sedated to perform the procedure. Our lab has previously developed technology termed tethered capsule OCT endomicroscopy (TCE) to overcome these diagnostic limitations of endoscopy. TCE involves swallowing an optomechanically-engineered pill that generates 3D images of the GI tract as it traverses the lumen of the organ via peristalsis, assisted by gravity. In several patients we have demonstrated TCE imaging of duodenal villi, however the current TCE device design is not optimal for CD diagnosis as the villi compress when in contact with the smooth capsule's wall. In this work, we present methods for structuring the outer surface of the capsule to improve the visualization of the villi height and crypt depth. Preliminary results in humans suggest that new TCE capsule enables better visualization of villous architecture, making it possibly to comprehensively scan the entire duodenum to obtain a more accurate tissue diagnosis of CD.
Luan, Zi Jian; Li, Yue; Zhao, Xin Yu; Wang, Li; Sun, Ying Hao; Wang, Shi Yao; Qian, Jia Ming
2016-10-01
To evaluate the efficacy and safety of low-dose azathioprine (AZA) in treating patients with chronic active ulcerative colitis (UC). A literature search of Medline, Embase, the Cochrane Library, Web of Science, Wanfang Database, CNKI, SinoMed, VIP Chinese Science and the Technology Journals Database was conducted to identify eligible studies that evaluated the efficacy and safety of low-dose azathioprine (AZA) in treating patients with chronic active UC published up to 15 July 2015. Data were extracted from the studies, including clinical efficacy (response rate, adverse drug reaction [ADR] rate, steroid withdrawal rate and relapse rate) and endoscopic improvement (endoscopic remission rate and mucosal healing rate). Six studies with 211 patients were eligible for the analysis. The overall response rates after 6 and 12 months of treatment were 78.0% (95% confidence interval [CI] 71.0-85.0%) and 88.0% (95% CI 80.0-96.0%), respectively. The overall ADR rate was 25.0% (95% CI 18.0-31.0%). Endoscopic response rate was around 85.0%, while the endoscopic remission rates and mucosal healing rates after 6 and 12 months of treatment were above 60.0% and 70.0%, respectively. The steroid withdrawal rate and relapse rate were in moderate to high heterogeneity. Egger's test indicated that there was no publication bias for studies regarding the 6-month response rate and ADR rate. Low-dose AZA is effective and safe in the treatment of chronic active UC patients. However, randomized controlled trials with large sample sizes are needed to draw definitive conclusions. © 2016 Chinese Medical Association Shanghai Branch, Chinese Society of Gastroenterology, Renji Hospital Affiliated to Shanghai Jiaotong University School of Medicine and John Wiley & Sons Australia, Ltd.
Perrod, Guillaume; Pidial, Laetitia; Camilleri, Sophie; Bellucci, Alexandre; Casanova, Amaury; Viel, Thomas; Tavitian, Bertrand; Cellier, Chirstophe; Clément, Olivier; Rahmi, Gabriel
2017-02-10
In past years, the cell-sheet construct has spurred wide interest in regenerative medicine, especially for reconstructive surgery procedures. The development of diversified technologies combining adipose tissue-derived stromal cells (ADSCs) with various biomaterials has led to the construction of numerous types of tissue-engineered substitutes, such as bone, cartilage, and adipose tissues from rodent, porcine, or human ADSCs. Extended esophageal endoscopic submucosal dissection (ESD) is responsible for esophageal stricture formation. Stricture prevention remains challenging, with no efficient treatments available. Previous studies reported the effectiveness of mucosal cell-sheet transplantation in a canine model and in humans. ADSCs are attributed anti-inflammatory properties, local immune modulating effects, neovascularization induction, and differentiation abilities into mesenchymal and non-mesenchymal lineages. This original study describes the endoscopic transplantation of an ADSC tissue-engineered construct to prevent esophageal stricture in a swine model. The ADSC construct was composed of two allogenic ADSC sheets layered upon each other on a paper support membrane. The ADSCs were labeled with the PKH67 fluorophore to allow probe-based confocal laser endomicroscopy (pCLE) monitoring. On the day of transplantation, a 5-cm and hemi-circumferential ESD known to induce esophageal stricture was performed. Animals were immediately endoscopically transplanted with 4 ADSC constructs. The complete adhesion of the ADSC constructs was obtained after 10 min of gentle application. Animals were sacrificed on day 28. All animals were successfully transplanted. Transplantation was confirmed on day 3 with a positive pCLE evaluation. Compared to transplanted animals, control animals developed severe strictures, with major fibrotic tissue development, more frequent alimentary trouble, and reduced weight gain. In our model, the transplantation of allogenic ADSCs, organized in double cell sheets, after extended ESD was successful and strongly associated with a lower esophageal stricture rate.
Holland, Pat; Shoop, Nancy M
2002-01-01
Flexible endoscopes are complex medical instruments that are easily damaged. In order to maintain the flexible endoscope in optimum working condition, the user must have a thorough understanding of the structure and function of the instrument. This is the fourth in a series of articles presenting an in-depth look at the care and handling of the flexible endoscope. The first three articles discussed the air-water system, the suction channel system, and the mechanical system. This article will focus specifically on the endoscopic retrograde cholangiopancreatography elevator system.
Nakajima, Kiyokazu; Takahashi, Tsuyoshi; Souma, Yoshihito; Shinzaki, Shinichiro; Yamada, Takuya; Yoshio, Toshiyuki; Nishida, Toshirou
2008-12-01
Transvaginal natural orifice translumenal endoscopic surgery (NOTES) gastrectomy is technically challenging, because wide perigastric dissection under appropriate tissue triangulation is unfeasible with current endoscopic instruments alone. The aim of this study was to investigate the feasibility of transvaginal NOTES gastrectomy with the use of an extra endoscope as a retracting device of the stomach. This acute in vivo feasibility study was performed under the approval of the Institutional Animal Care and Use Committee (IACUC). Four female 40-kg pigs received general anesthesia and underwent transvaginal endoscopic partial gastrectomy. Under laparoscopic guidance, the uterus was fixed anteriorly and transvaginal access was established in a standard fashion. The perigastric ligaments were dissected with needle knife/insulation-tipped electrosurgical knife (IT) via transvaginally placed double-channel endoscope. This step was assisted with the second, CO(2)-insufflating endoscope advanced in the stomach (i.e., so-called endoscopic gastric control). A linear stapling device with a flexible shaft was then passed transvaginally, and the anterior gastric wall was partially resected. The specimen was isolated and retrieved through the vagina. Concluding endoscopy was carried out to confirm the absence of mucosal damage due to endoscopic gastric control. This was further confirmed at necropsy immediately after sacrifice. All animals underwent successful transvaginal NOTES gastrectomy. Endoscopic gastric control greatly facilitated perigastric dissection by providing appropriate tissue countertraction on the ligaments. Use of transabdominal (laparoscopic) graspers was thus minimized. There were no intraoperative complications directly related to use of the primary (transvaginal) endoscope or the additional (gastric) endoscope. Distention of downstream bowel after gastric insufflation was minimal with CO(2). No major injuries were noted on gastric mucosa at postmortem investigations. Transvaginal NOTES partial gastrectomy is feasible in porcine models. Use of an extra endoscope to retract the stomach is effective to minimize transabdominal assistance. Further studies on human subjects are necessary to establish this as a safe and attractive ancillary technique in NOTES.
In-Use Evaluation of Peracetic Acid for High-Level Disinfection of Endoscopes.
Chenjiao, Wu; Hongyan, Zhang; Qing, Gu; Xiaoqi, Zhong; Liying, Gu; Ying, Fang
2016-01-01
Many high-level disinfectants have been used for disinfection of endoscopes such as 2% glutaraldehyde (GA), 0.55% ortho-phthalaldehyde (OPA), and peracetic acid (PAA). Both GA and OPA are widely used in disinfection of endoscopes and have been previously discussed, but there is little research on the practical use of PAA as an endoscope disinfectant. An experimental model of a flexible gastrointestinal endoscope being contaminated with 9 strains of microorganism was designed. After the cleaning and disinfecting procedure was completed, we evaluated the biocidal activity (850 ppm PAA, 2% GA, and 0.55% OPA) on our flexible gastrointestinal endoscope model. We also evaluated sterilization effectiveness of PAA on other bacteria, including some antibiotic-resistant bacteria (methicillin-resistant Staphylococcus aureus, vancomycin-resistant Enterococcus, and Clostridium difficile). The residual bacterial colony count number of the PAA-disinfected endoscope was significantly lower than that of the GA- and OPA-disinfected endoscopes. The biocidal effect and efficiency of the endoscope disinfection by PAA appeared to be better than either the GA- or OPA-disinfected endoscope. PAA has demonstrated a good sterilization effect on other bacterial species; of particular note are common antibiotic-resistant bacteria such as methicillin-resistant Staphylococcus aureus, vancomycin-resistant Enterococcus, and Clostridium difficile. The results of this study demonstrate that PAA is a fast and effective high-level disinfectant for use in the reprocessing of flexible endoscopes.
Yabe, Shuntaro; Kato, Hironari; Mizukawa, Sho; Akimoto, Yutaka; Uchida, Daisuke; Seki, Hiroyuki; Tomoda, Takeshi; Matsumoto, Kazuyuki; Yamamoto, Naoki; Horiguchi, Shigeru; Tsutsumi, Koichiro; Okada, Hiroyuki
2017-05-01
Endoscopic procedures are used as first-line treatment for bile leak after hepatobiliary surgery. Advances have been made in endoscopic techniques and devices, but few reports have described the effectiveness of endoscopic procedures and the management principles based on severity of bile leak. We evaluated the effectiveness of an endoscopic procedure for the treatment of bile leak after hepatobiliary surgery. Fifty-eight patients underwent an endoscopic procedure for suspected bile leak after hepatobiliary surgery; the presence of bile leak on endoscopic retrograde cholangiopancreatography (ERCP) was evaluated retrospectively. Two groups were created based on bile leak severity at ERCP. We defined success as follows: technical, successful placement of the plastic stent at the intended bile duct; clinical, improvement in symptoms of bile leak; and eventual, disappearance of bile leak at ERCP. We evaluated several factors that influenced the success of the endoscopic procedure and the differences between bile leak severity. Success rates were as follows: technical, 90%; clinical, 79%; and eventual, 71%. Median interval between first endoscopic procedure and achievement of eventual success was 135 days (IQR, 86-257 days). Bile leak severity was the only independent factor associated with eventual success (P = 0.01). Endoscopic therapy is safe and effective for postoperative bile leak. Bile leak severity is the most important factor influencing successful endoscopic therapy. © 2016 Japan Gastroenterological Endoscopy Society.
Sen-yo, Manabu; Kaino, Seiji; Suenaga, Shigeyuki; Uekitani, Toshiyuki; Yoshida, Kanako; Harano, Megumi; Sakaida, Isao
2012-01-01
Background/Purpose. The difficulties of endoscopic retrograde cholangiopancreatography in patients with Billroth II gastrectomy have been reported. We evaluated the usefulness of an anterior oblique-viewing endoscope and a double-balloon enteroscope for endoscopic retrograde cholangiopancreatography in such patients. Methods. From January 2003 to December 2011, 65 patients with Billroth II gastrectomy were enrolled in this study. An anterior oblique-viewing endoscope was used for all patients. From February 2007, a double-balloon enteroscope was used for the failed cases. The success rate of procedures was compared with those in 20 patients with Billroth II gastrectomy using forward-viewing endoscope or side-viewing endoscope from March 1996 to July 2002 as historical controls. Results. In all patients in whom the papilla was reached (60/65), selective cannulation was achieved. The success rate of selective cannulation and accomplishment of planned procedures in the anterior oblique-viewing endoscope group were both significantly higher than that in the control group (100% versus 70.1%, 100 versus 58.8%, resp.). A double-balloon enteroscope was used in 2 patients, and the papilla could be reached and the planned procedures completed. Conclusions. An anterior oblique-viewing endoscope and double-balloon enteroscope appear to be useful in performing endoscopic retrograde cholangiopancreatography in patients with Billroth II gastrectomy. PMID:23056039
Lv, Houning; Zhao, Ningning; Zheng, Zhongqing; Wang, Tao; Yang, Fang; Jiang, Xihui; Lin, Lin; Sun, Chao; Wang, Bangmao
2017-05-01
Peroral endoscopic myotomy (POEM) has emerged as an advanced technique for the treatment of achalasia, and defining the learning curve is mandatory. From August 2011 to June 2014, two operators in our institution (A&B) carried out POEM on 35 and 33 consecutive patients, respectively. Moving average and cumulative sum (CUSUM) methods were used to analyze the POEM learning curve for corrected operative time (cOT), referring to duration of per centimeter myotomy. Additionally, perioperative outcomes were compared among distinct learning curve phases. Using the moving average method, cOT reached a plateau at the 29th case and at the 24th case for operators A and B, respectively. CUSUM analysis identified three phases: initial learning period (Phase 1), efficiency period (Phase 2) and mastery period (Phase 3). The relatively smooth state in the CUSUM graph occurred at the 26th case and at the 24th case for operators A and B, respectively. Mean cOT of distinct phases for operator A were 8.32, 5.20 and 3.97 min, whereas they were 5.99, 3.06 and 3.75 min for operator B, respectively. Eckardt score and lower esophageal sphincter pressure significantly decreased during the 1-year follow-up period. Data were comparable regarding patient characteristics and perioperative outcomes. This single-center study demonstrated that expert endoscopists with experience in esophageal endoscopic submucosal dissection reached a plateau in learning of POEM after approximately 25 cases. © 2016 Japan Gastroenterological Endoscopy Society.
Teles-Sampaio, Elvira; Maia, Luís; Salgueiro, Paulo; Marcos-Pinto, Ricardo; Dinis-Ribeiro, Mário; Pedroto, Isabel
2016-11-01
Nonvariceal upper gastrointestinal bleeding emerges as a major complication of using antiplatelet agents and/or anticoagulants and represents a clinical challenge in patients undergoing these therapies. To characterize patients with nonvariceal upper gastrointestinal bleeding related to antithrombotics and their management, and to determine clinical predictors of adverse outcomes. Retrospective cohort of adults who underwent upper gastrointestinal endoscopy after nonvariceal upper gastrointestinal bleeding from 2010 to 2012. The outcomes were compared between patients exposed and not exposed to antithrombotics. Five hundred and forty-eight patients with nonvariceal upper gastrointestinal bleeding (67% men; mean age 66.5 ± 16.4 years) were included, of which 43% received antithrombotics. Most patients had comorbidities. Peptic ulcer was the main diagnosis and endoscopic therapy was performed in 46% of cases. The 30-day mortality rate was 7.7% (n = 42), and 36% were bleeding-related. The recurrence rate was 9% and 14% of patients with initial endoscopic treatment needed endoscopic retreatment. There were no significant differences between the exposed and non-exposed groups in most outcomes. Co-morbidities, hemodynamic instability, high Rockall score, low hemoglobin (7.76 ± 2.72 g/dL) and higher international normalized ratio (1.63 ± 1.13) were associated significantly with mortality in a univariate analysis. Adverse outcomes were not associated with antithrombotic use. The management of nonvariceal upper gastrointestinal bleeding constitutes a challenge to clinical performance optimization and clinical cooperation.
Endoscopic findings in upper gastrointestinal bleeding patients at Lacor hospital, northern Uganda.
Alema, O N; Martin, D O; Okello, T R
2012-12-01
Upper gastrointestinal bleeding (UGIB) is a common emergency medical condition that may require hospitalization and resuscitation, and results in high patient morbidity. Upper gastrointestinal endoscopy is the preferred investigative procedure for UGIB because of its accuracy, low rate of complication, and its potential for therapeutic interventions. To determine the endoscopic findings in patients presenting with UGIB and its frequency among these patients according to gender and age in Lacor hospital, northern Uganda. The study was carried out at Lacor hospital, located at northern part of Uganda. The record of 224 patients who underwent endoscopy for upper gastrointestinal bleeding over a period of 5 years between January 2006 and December 2010 were retrospectively analyzed. A total of 224 patients had endoscopy for UGIB which consisted of 113 (50.4%) males and 111 (49.6%) females, and the mean age was 42 years ± SD 15.88. The commonest cause of UGIB was esophagealvarices consisting of 40.6%, followed by esophagitis (14.7%), gastritis (12.6%) and peptic ulcer disease (duodenal and gastric ulcers) was 6.2%. The malignant conditions (gastric and esophageal cancers) contributed to 2.6%. Other less frequent causes of UGIB were hiatus hernia (1.8), duodenitis (0.9%), others-gastric polyp (0.4%). Normal endoscopic finding was 16.1% in patients who had UGIB. Esophageal varices are the commonest cause of upper gastrointestinal bleeding in this environment as compared to the west which is mainly peptic ulcer disease.
Principles of endoscopic ear surgery.
Tarabichi, Muaaz; Kapadia, Mustafa
2016-10-01
The aim of this review is to study the rationale, limitations, techniques, and long-term outcomes of endoscopic ear surgery. The article discusses the advantages of endoscopic ear surgery in treating cholesteatoma and how the hidden sites like facial recess, sinus tympani, and anterior epitympanum are easily accessed using the endoscope. Transcanal endoscopic approach allows minimally invasive removal of cholesteatoma with results that compare well to traditional postauricular tympanomastoidectomy.
Garcia-Planella, Esther; Mañosa, Míriam; Cabré, Eduard; Marín, Laura; Gordillo, Jordi; Zabana, Yamile; Boix, Jaume; Sáinz, Sergio; Domènech, Eugeni
2016-12-01
Fecal calprotectin (FC) is the best noninvasive biomarker of disease activity in inflammatory bowel disease. Its correlation with endoscopic mucosal lesions could save inconvenient, expensive, and repeated endoscopic examinations in particular clinical settings. To assess the correlation between FC and the existence and severity of endoscopic postoperative recurrence (POR), a group of clinically stable outpatients with Crohn's disease for whom an ileocolonoscopy was routinely planned to assess POR were invited to collect a stool sample before starting bowel cleansing to measure FC. POR was graded by means of Rutgeerts endoscopic score. One hundred nineteen ileocolonoscopies were included, 42% with endoscopic POR. FC was significantly lower in the absence of endoscopic POR and in the absence of any endoscopic lesion. The area under the receiver operating characteristic curve was 0.76 (95% confidence interval, 0.68-0.85) for the diagnosis of the absence of lesions and 0.75 (95% confidence interval, 0.66-0.84) for endoscopic POR. Better sensitivity and negative predictive value were observed when combining FC and serum C-reactive protein (CRP), leading to a sensitivity of 82%, a specificity of 53%, and negative and positive predictive values of 81% and 54%, respectively, for the prediction of endoscopic POR with a combination of FC 100 μg/g and CRP 5 mg/L cutoff values. FC correlates closely with endoscopic POR in clinically stable postoperative patients with Crohn's disease and, when used in combination with CRP, might save endoscopic examinations and allow for a high-grade suspicion of endoscopic POR in the long-term monitoring of these patients.
Endoscopic manometry of the sphincter of Oddi in sphincterotomized patients.
Ugljesić, M; Bulajić, M; Milosavljević, T; Stimec, B
1995-01-01
Endoscopic sphincterotomy (ES) of the sphincter of Oddi (SO) has been accepted as an effective method in extraction of common bile duct stones in postcholecystectomy patients. The purpose of this study was to examine the completeness of the performed ES and observe the post sphincterotomy pancreatic duct sphincter (PDS) activity using endoscopic manometry. Activity of the sphincter of Oddi was examined in 15 sphincterotomized patients using endoscopic manometry one to 2.5 years after endoscopic sphincterotomy for choledocholithiasis. In eight patients absence of choledochoduodenal gradient, baseline pressure and the sphincter of Oddi phasic activity up to 2.5 years after endoscopic sphincterotomy indicated a complete sphincterotomy. In seven patients with incomplete endoscopic sphincterotomy, manometry exhibited either a lower choledochoduodenal gradient and baseline pressure without phasic activity of the sphincter of Oddi (three patients), a sphincter of Oddi activity without choledochoduodenal gradient (one patient), or a complete restitution of the sphincter of Oddi activity 1 to 2 years after endoscopic sphincterotomy (three patients). In five patients, with complete endoscopic sphincterotomy, measurements of pancreatic sphincter activity showed lower values of the pancreatic ductal pressure and baseline pressure, while the pancreatic sphincter phasic activity was equal to that found in the control group. Endoscopic manometry is method which enables us to test the completeness of endoscopic sphincterotomy and to follow the restitution of the phasic contractile function of the sphincter. Manometric findings reveal pancreatic sphincter in most patients as a separate sphincteric entity, the function of which is reduced but not eliminated by a complete endoscopic sphincterotomy.
Quality assurance manual of endoscopic screening for gastric cancer in Japanese communities.
Hamashima, Chisato; Fukao, Akira
2016-09-02
The Japanese government introduced endoscopic screening for gastric cancer in 2015 as a public policy based on the Japanese guidelines on gastric cancer screening. To provide appropriate endoscopic screening for gastric cancer in Japanese communities, we developed a quality assurance manual of endoscopic screening and recommend 10 strategies with their brief descriptions as follows: (i) Formulation of a committee responsible for implementing and managing endoscopic screening, and for deciding the suitable implementation methods in consideration of the local context; (ii) Development of an interpretation system that leads to a final judgement to standardize endoscopic examination and improve its accuracy; (iii) Preparation of management and reporting systems for adverse effects by the committee for safety management; (iv) Obtaining informed consent before operation following adequate explanations regarding the benefits and harms of endoscopic screening; (v) Avoidance of frequent screenings to reduce false-positive results and overdiagnosis. As a reference, the target age group is ≥50 years, and the screening interval is 2 years; (vi) Keeping the biopsy rate within 10% as post-biopsy bleeding may occur. Before endoscopic screening, any history of antithrombotic drug usage should be checked; (vii) Nonadministration of sedation in endoscopic screening for safety management; (viii) Adherence to proper endoscopic cleaning and disinfection to reduce infection; (ix) Use of a checklist to achieve optimal program preparation when municipal governments introduce endoscopic screening; (x) Identification of the aims and roles by referring to a checklist if primary care physicians decide to participate in endoscopic screening. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Endoscopic versus surgical drainage treatment of calcific chronic pancreatitis.
Jiang, Li; Ning, Deng; Cheng, Qi; Chen, Xiao-Ping
2018-04-21
Endoscopic therapy and surgery are both conventional treatments to remove pancreatic duct stones that developed during the natural course of chronic pancreatitis. However, few studies comparing the effect and safety between surgery drainage and endoscopic drainage (plus Extracorporeal Shock Wave Lithotripsy, ESWL).The aim of this study was to compare the benefits between endoscopic and surgical drainage of the pancreatic duct for patients with calcified chronic pancreatitis. A total of 86 patients were classified into endoscopic/ESWL (n = 40) or surgical (n = 46) treatment groups. The medical records of these patients were retrospectively analyzed. Pain recurrence and hospital stays were similar between the endoscopic/ESWL treatment and surgery group. However, endoscopic/ESWL treatment yielded significantly lower medical expense and less complications compared with the surgical treatment. In selective patients, endoscopic/ESWL treatment could achieve comparable efficacy to the surgical treatment. With lower medical expense and less complications, endoscopic/ESWL treatment would be much preferred to be the initial treatment of choice for patients with calcified chronic pancreatitis. Copyright © 2018 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.
Endoscopic management of pancreatic fluid collections-revisited
Nabi, Zaheer; Basha, Jahangeer; Reddy, D Nageshwar
2017-01-01
The development of pancreatic fluid collections (PFC) is one of the most common complications of acute severe pancreatitis. Most of the acute pancreatic fluid collections resolve and do not require endoscopic drainage. However, a substantial proportion of acute necrotic collections get walled off and may require drainage. Endoscopic drainage of PFC is now the preferred mode of drainage due to reduced morbidity and mortality as compared to surgical or percutaneous drainage. With the introduction of new metal stents, the efficiency of endoscopic drainage has improved and the task of direct endoscopic necrosectomy has become easier. The requirement of re-intervention is less with new metal stents as compared to plastic stents. However, endoscopic drainage is not free of adverse events. Severe complications including bleeding, perforation, sepsis and embolism have been described with endoscopic approach to PFC. Therefore, the endoscopic management of PFC is a multidisciplinary affair and involves interventional radiologists as well as GI surgeons to deal with unplanned adverse events and failures. In this review we discuss the recent advances and controversies in the endoscopic management of PFC. PMID:28487603
Endoscopic management of colorectal adenomas.
Meier, Benjamin; Caca, Karel; Fischer, Andreas; Schmidt, Arthur
2017-01-01
Colorectal adenomas are well known precursors of invasive adenocarcinoma. Colonoscopy is the gold standard for adenoma detection. Colonoscopy is far more than a diagnostic tool, as it allows effective treatment of colorectal adenomas. Endoscopic resection of colorectal adenomas has been shown to reduce the incidence and mortality of colorectal cancer. Difficult resection techniques are available, such as endoscopic mucosal resection, endoscopic submucosal dissection and endoscopic full-thickness resection. This review aims to provide an overview of the different endoscopic resection techniques and their indications, and summarizes the current recommendations in the recently published guideline of the European Society of Gastrointestinal Endoscopy.
Endoscopic management of colorectal adenomas
Meier, Benjamin; Caca, Karel; Fischer, Andreas; Schmidt, Arthur
2017-01-01
Colorectal adenomas are well known precursors of invasive adenocarcinoma. Colonoscopy is the gold standard for adenoma detection. Colonoscopy is far more than a diagnostic tool, as it allows effective treatment of colorectal adenomas. Endoscopic resection of colorectal adenomas has been shown to reduce the incidence and mortality of colorectal cancer. Difficult resection techniques are available, such as endoscopic mucosal resection, endoscopic submucosal dissection and endoscopic full-thickness resection. This review aims to provide an overview of the different endoscopic resection techniques and their indications, and summarizes the current recommendations in the recently published guideline of the European Society of Gastrointestinal Endoscopy. PMID:29118553
Kim, Hee Man; Choi, Ja Sung; Cho, Jae Hee
2014-04-30
The magnetic capsule endoscope has been modified to be fixed inside the stomach and to monitor the gastric motility. This pilot trial was designed to investigate the feasibility of the magnetic capsule endoscope for monitoring gastric motility. The magnetic capsule endoscope was swallowed by the healthy volunteer and maneuvered by the external magnet on his abdomen surface inside the stomach. The magnetic capsule endoscope transmitted image of gastric peristalsis. This simple trial suggested that the real-time ambulatory monitoring of gastric motility should be feasible by using the magnetic capsule endoscope.
Natural history of endoscopically detected hiatus herniae at late follow-up.
Ahmed, Syeda Khadijah; Bright, Tim; Watson, David I
2018-06-01
Hiatus herniae are commonly seen at endoscopy. Many patients with a large hiatus hernia are endoscoped for symptoms associated with the hernia and many of these will progress to surgical treatment. However, little is known about the natural history of small to medium size hiatus herniae, and their risk of progressing to a larger hernia requiring surgery. This study aims to determine the need for subsequent surgery in these patients. A retrospective audit of the endoscopy database at Flinders Medical Centre and the Repatriation General Hospital in Adelaide, South Australia for the 2-year period 2002-2003 was performed to identify all patients with a hiatus hernia. Patients under the age of 65 and with a sliding hiatus hernia <5 cm in length were selected for this study, and sent a questionnaire which determines the long-term (>10 years) outcome of these herniae. Small- to medium-sized hiatus herniae (<5 cm length) were found at 10% of endoscopies performed. In this group, 38% had reflux as the indication for endoscopy. 1.5% subsequently progressed to anti-reflux surgery or hiatus hernia repair. Thirty-nine percent reported being on proton pump inhibitors for symptom control. No patients required emergency surgical repair of their hiatus hernia. While patients with small- to medium-sized sliding hiatus hernia commonly have symptomatic reflux, an acute problem requiring emergency surgery is unlikely over long-term follow-up. © 2017 Royal Australasian College of Surgeons.
Krishnamoorthy, Bhuvaneswari; Critchley, William R; Nair, Janesh; Malagon, Ignacio; Carey, John; Barnard, James B; Waterworth, Paul D; Venkateswaran, Rajamiyer V; Fildes, James E; Caress, Ann L; Yonan, Nizar
The aim of the study was to assess whether the use of carbon dioxide insufflation has any impact on integrity of long saphenous vein comparing 2 types of endoscopic vein harvesting and traditional open vein harvesting. A total of 301 patients were prospectively randomized into 3 groups. Group 1 control arm of open vein harvesting (n = 101), group 2 closed tunnel (carbon dioxide) endoscopic vein harvesting (n = 100) and Group 3 open tunnel (carbon dioxide) endoscopic vein harvesting (open tunnel endoscopic vein harvesting) (n = 100). Each group was assessed to determine the systemic level of partial arterial carbon dioxide, end-tidal carbon dioxide, and pH. Three blood samples were obtained at baseline, 10 minutes after start of endoscopic vein harvesting, and 10 minutes after the vein was retrieved. Vein samples were taken immediately after vein harvesting without further surgical handling to measure the histological level of endothelial damage. A modified validated endothelial scoring system was used to compare the extent of endothelial stretching and detachment. The level of end-tidal carbon dioxide was maintained in the open tunnel endoscopic vein harvesting and open vein harvesting groups but increased significantly in the closed tunnel endoscopic vein harvesting group (P = 0.451, P = 0.385, and P < 0.001). Interestingly, partial arterial carbon dioxide also did not differ over time in the open tunnel endoscopic vein harvesting group (P = 0.241), whereas partial arterial carbon dioxide reduced significantly over time in the open vein harvesting group (P = 0.001). A profound increase in partial arterial carbon dioxide was observed in the closed tunnel endoscopic vein harvesting group (P < 0.001). Consistent with these patterns, only the closed tunnel endoscopic vein harvesting group demonstrated a sudden drop in pH over time (P < 0.001), whereas pH remained stable for both open tunnel endoscopic vein harvesting and open vein harvesting groups (P = 0.105 and P = 0.869, respectively). Endothelial integrity was better preserved in the open vein harvesting group compared with open tunnel endoscopic vein harvesting or closed tunnel endoscopic vein harvesting groups (P = 0.012) and was not affected by changes in carbon dioxide or low pH. Significantly greater stretching of the endothelium was observed in the open tunnel endoscopic open tunnel endoscopic vein harvesting group compared with the other groups (P = 0.003). This study demonstrated that the different vein harvesting techniques impact on endothelial integrity; however, this does not seem to be related to the increase in systemic absorption of carbon dioxide or to the pressurized endoscopic tunnel. The open tunnel endoscopic harvesting technique vein had more endothelial stretching compared with the closed tunnel endoscopic technique; this may be due to manual dissection of the vein. Further research is required to evaluate the long-term clinical outcome of these vein grafts.
Kato, Shin; Kuwatani, Masaki; Sugiura, Ryo; Sano, Itsuki; Kawakubo, Kazumichi; Ono, Kota; Sakamoto, Naoya
2017-01-01
Introduction The effect of endoscopic sphincterotomy prior to endoscopic biliary stenting to prevent post-endoscopic retrograde cholangiopancreatography pancreatitis remains to be fully elucidated. The aim of this study is to prospectively evaluate the non-inferiority of non-endoscopic sphincterotomy prior to stenting for naïve major duodenal papilla compared with endoscopic sphincterotomy prior to stenting in patients with biliary stricture. Methods and analysis We designed a multicentre randomised controlled trial, for which we will recruit 370 patients with biliary stricture requiring endoscopic biliary stenting from 26 high-volume institutions in Japan. Patients will be randomly allocated to the endoscopic sphincterotomy group or the non-endoscopic sphincterotomy group. The main outcome measure is the incidence of pancreatitis within 2 days of initial transpapillary biliary drainage. Data will be analysed on completion of the study. We will calculate the 95% confidence intervals (CIs) of the incidence of pancreatitis in each group and analyse weather the difference in both groups with 95% CIs is within the non-inferiority margin (6%) using the Wald method. Ethics and dissemination This study has been approved by the institutional review board of Hokkaido University Hospital (IRB: 016–0181). Results will be submitted for presentation at an international medical conference and published in a peer-reviewed journal. Trial registration number The University Hospital Medical Information Network ID: UMIN000025727 Pre-results. PMID:28801436
Toirac, Alexander; Giugale, Juan M; Fowler, John R
2017-05-01
Endoscopic cubital tunnel release has been proposed as an alternative to open in situ release. However, it is difficult to analyze outcomes after endoscopic release, as only a few small case series exist. The electronic databases of PubMed (1960-June 2014) were systematically screened for studies related to endoscopic cubital tunnel release or open in situ cubital tunnel release. Baseline characteristics, clinical scores, and complication rates were abstracted. The binary outcome was defined as rate of excellent/good response versus fair/poor. Complications were recorded into 3 categories: wound problems, persistent ulnar nerve symptoms, and other. We included 8 articles that reported the clinical outcomes after surgical intervention including a total of 494 patients (344 endoscopic, 150 open in situ). The pooled rate of excellent/good was 92.0% (88.8%-95.2%) for endoscopic and 82.7% (76.15%-89.2%) for open. We identified 18 articles that detailed complications including a total of 1108 patients (691 endoscopic, 417 open). The 4 articles that listed complication rates for both endoscopic and open techniques were analyzed and showed a pooled odds ratio of 0.280 (95% confidence interval, 0.125-0.625), indicating that endoscopic patients have reduced odds of complications. The results of this systematic review suggest that there is a difference in clinical outcomes between the open in situ and endoscopic cubital tunnel release, with the endoscopic technique being superior in regard to both complication rates along with patient satisfaction.
Singhi, Aditi
2009-01-01
Study Objectives: (a) To find out the actual incidence of complications during endoscopic surgeries. (b) Comparison of complication rate between an experienced laparoscopic surgeon (> 10 years of experience in endoscopic surgery) and a clinical assistant (> 3 years of experience in endoscopic surgery). (c) How to manage complications in endoscopic surgery. (d) Concrete suggestions to reduce the complication rate. Design: Retrospective study (Canadian Task Force classification ii-2). Setting: Tertiary gynecologic endoscopic unit. Patients: A total of 3204 cases of gynecologic endoscopic surgery out of which 2001 were laparoscopic and 1203 were hysteroscopic surgeries. Interventions: Laparoscopic and hysteroscopic gynecologic surgeries in indicated cases. Measurements and Main Results: The study was carried out between April 2003 and October 2007 at a referral center for endoscopic surgery. A total of 3204 cases of gynecologic endoscopic surgery were studied. There were five significant complications in laparoscopic surgeries and four significant complications in hysteroscopic surgeries seen in four years and six months. All the complications could be managed with no mortality. Conversion to laparotomy was needed in eight cases of laparoscopic surgeries and none in hysteroscopic surgeries. Conclusion: The risk of complication reduces with the experience in endoscopic surgery. However, the proper grooming of a novice in experienced hands, for a sufficient period of time, can minimize the complication rate in the initial learning phase. The complication may be utilized as a stepping-stone to overcome any given situation without panic, but with adequate safety. PMID:22442510
[TITANIUM NICKELIDE TECHNOLOGIES IN MINIMALLY INVASIVE SURGERY OF KIDNEY AND UPPER URINARY TRACT].
Feofilov, L V
2015-01-01
The most common pathology of the kidney and upper urinary tract includes nephrolithiasis, ureteral strictures and renal cysts. In the treatment of patients with these diseases, the majority of surgeons prefer minimally invasive techniques, including endoscopic surgery. The complication rate of percutaneous surgery is a major factor in encouraging the search for new treatments. We have analyzed the results of 402 x-ray-endoscopic operations performed with the use of technologies based on titanium nickelide materials in patients with nephrolithiasis, ureteral strictures and kidney cysts. The high effectiveness and reliability of porous titanium nickelide cryoapplicator was noted in control of percutaneous channel bleeding and prevention. The proposed suspension nephropexy with fine titanium granules in coexisting nephrolithiasis and nephroptosis demonstrated 1.5 times greater effectiveness compared to the traditional nephropexy, reducing duration of nephrostomy and rehabilitation by almost 3 times. The proposed methods of intubation by permanent and temporary stents with shape memory after percutaneous ureteropelvic junction stricture correction are promising in the treatment of patients with this pathology of the upper urinary tract. Application of titanium nickelide implants in simple renal cyst surgery has led to a significant increase in the effectiveness of these operations, improvement in long-term results and patients' quality of life.
A new technique to expose the hypopharyngeal space: The modified Killian's method.
Sakai, Akihiro; Okami, Kenji; Sugimoto, Ryousuke; Ebisumoto, Koji; Yamamoto, Hikaru; Maki, Daisuke; Saito, Kosuke; Iida, Masahiro
2014-04-01
Recent remarkable progress in endoscopic technology has enabled the detection of superficial cancers that were undetectable in the past. However, even though advanced endoscopic technology can detect early lesions, it is useless unless it can provide wide exposure of an area. By modifying the Killian position, it is possible to observe a wider range of the hypopharyngeal space than is possible with conventional head positions. We report a revolutionary method that uses a new head position to widely open the hypopharynx. The technique is named "the Modified Killian's method." The patient is initially placed in the Killian position and then bent further forward from the original position (i.e., the modified Killian position). While in this position, the patient's head is turned and the Valsalva maneuver is applied. These additional maneuvers constitute the Modified Killian's method and widely expands the hypopharyngeal space. The conventional head position cannot open the hypopharyngeal space sufficiently; however, the Modified Killian's method opens the hypopharyngeal space very widely. The Modified Killian's method enables observation of the entire circumference of the hypopharyngeal space and the cervical esophageal entry. The Modified Killian's method may become an indispensable technique for observing the hypopharynx and detecting hypopharyngeal cancers. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
Wireless fluorescence capsule for endoscopy using single photon-based detection
NASA Astrophysics Data System (ADS)
Al-Rawhani, Mohammed A.; Beeley, James; Cumming, David R. S.
2015-12-01
Fluorescence Imaging (FI) is a powerful technique in biological science and clinical medicine. Current FI devices that are used either for in-vivo or in-vitro studies are expensive, bulky and consume substantial power, confining the technique to laboratories and hospital examination rooms. Here we present a miniaturised wireless fluorescence endoscope capsule with low power consumption that will pave the way for future FI systems and applications. With enhanced sensitivity compared to existing technology we have demonstrated that the capsule can be successfully used to image tissue autofluorescence and targeted fluorescence via fluorophore labelling of tissues. The capsule incorporates a state-of-the-art complementary metal oxide semiconductor single photon avalanche detector imaging array, miniaturised optical isolation, wireless technology and low power design. When in use the capsule consumes only 30.9 mW, and deploys very low-level 468 nm illumination. The device has the potential to replace highly power-hungry intrusive optical fibre based endoscopes and to extend the range of clinical examination below the duodenum. To demonstrate the performance of our capsule, we imaged fluorescence phantoms incorporating principal tissue fluorophores (flavins) and absorbers (haemoglobin). We also demonstrated the utility of marker identification by imaging a 20 μM fluorescein isothiocyanate (FITC) labelling solution on mammalian tissue.
Development of a telediagnosis endoscopy system over secure internet.
Ohashi, K; Sakamoto, N; Watanabe, M; Mizushima, H; Tanaka, H
2008-01-01
We developed a new telediagnosis system to securely transmit high-quality endoscopic moving images over the Internet in real time. This system would enable collaboration between physicians seeking advice from endoscopists separated by long distances, to facilitate diagnosis. We adapted a new type of digital video streaming system (DVTS) to our teleendoscopic diagnosis system. To investigate its feasibility, we conducted a two-step experiment. A basic experiment was first conducted to transmit endoscopic video images between hospitals using a plain DVTS. After investigating the practical usability, we incorporated a secure and reliable communication function into the system, by equipping DVTS with "TCP2", a new security technology that establishes secure communication in the transport layer. The second experiment involved international transmission of teleendoscopic image between Hawaii and Japan using the improved system. In both the experiments, no serious transmission delay was observed to disturb physicians' communications and, after subjective evaluation by endoscopists, the diagnostic qualities of the images were found to be adequate. Moreover, the second experiment showed that "TCP2-equipped DVTS" successfully executed high-quality secure image transmission over a long distance network. We conclude that DVTS technology would be promising for teleendoscopic diagnosis. It was also shown that a high quality, secure teleendoscopic diagnosis system can be developed by equipping DVTS with TCP2.
Tan, Yuyong; Huo, Jirong; Liu, Deliang
2017-11-01
Gastrointestinal submucosal tumors (SMTs) have been increasingly identified via the use of endoscopic ultrasonography, and removal is often recommended for SMTs that are >2 cm in diameter or symptomatic. Submucosal tunneling endoscopic resection (STER), also known as submucosal endoscopic tumor resection, endoscopic submucosal tunnel dissection or tunneling endoscopic muscularis dissection, is a novel endoscopic technique for treating gastrointestinal SMTs originating from the muscularis propria layer, and has been demonstrated to be effective in the removal of SMTs with a decreased rate of recurrence by clinical studies. STER may be performed for patients with esophageal or cardia SMTs, and its application has expanded beyond these types of SMTs due to modifications to the technique. The present study reviewed the applications, procedure, efficacy and complications associated with STER.
Endoscopic treatments for portal hypertension.
Lo, Gin-Ho
2018-02-01
Acute esophageal variceal hemorrhage is a dreaded complication of portal hypertension. Its management has evolved rapidly in recent years. Endoscopic therapy is often employed to arrest bleeding varices as well as to prevent early rebleeding. The combination of vasoconstrictor and endoscopic therapy is superior to vasoconstrictor or endoscopic therapy alone for control of acute esophageal variceal hemorrhage. After control of acute variceal bleeding, combination of banding ligation and beta-blockers is generally recommended to prevent variceal rebleeding. To prevent the catastrophic event of acute variceal bleeding, endoscopic banding ligation is an important tool in the prophylaxis of first bleeding. Endoscopic obturation with cyanoacrylate is usually utilized to arrest acute gastric variceal hemorrhage as well as to prevent rebleeding. It can be concluded that endoscopic therapies play a pivotal role in management of portal hypertensive bleeding.
Supraretinacular endoscopic carpal tunnel release: surgical technique with prospective case series.
Ecker, J; Perera, N; Ebert, J
2015-02-01
Current techniques for endoscopic carpal tunnel release use an infraretinacular approach, inserting the endoscope deep to the flexor retinaculum. We present a supraretinacular endoscopic carpal tunnel release technique in which a dissecting endoscope is inserted superficial to the flexor retinaculum, which improves vision and the ability to dissect and manipulate the median nerve and tendons during surgery. The motor branch of the median nerve and connections between the median and ulnar nerve can be identified and dissected. Because the endoscope is inserted superficial to the flexor retinaculum, the median nerve is not compressed before division of the retinaculum and, as a result, we have observed no cases of the transient median nerve deficits that have been reported using infraretinacular endoscopic techniques. © The Author(s) 2014.
A research agenda for gastrointestinal and endoscopic surgery.
Urbach, D R; Horvath, K D; Baxter, N N; Jobe, B A; Madan, A K; Pryor, A D; Khaitan, L; Torquati, A; Brower, S T; Trus, T L; Schwaitzberg, S
2007-09-01
Development of a research agenda may help to inform researchers and research-granting agencies about the key research gaps in an area of research and clinical care. The authors sought to develop a list of research questions for which further research was likely to have a major impact on clinical care in the area of gastrointestinal and endoscopic surgery. A formal group process was used to conduct an iterative, anonymous Web-based survey of an expert panel including the general membership of the Society of American Gastrointestinal and Endoscopic Surgeons (SAGES). In round 1, research questions were solicited, which were categorized, collapsed, and rewritten in a common format. In round 2, the expert panel rated all the questions using a priority scale ranging from 1 (lowest) to 5 (highest). In round 3, the panel re-rated the 40 questions with the highest mean priority score in round 2. A total of 241 respondents to round 1 submitted 382 questions, which were reduced by a review panel to 106 unique questions encompassing 33 topics in gastrointestinal and endoscopic surgery. In the two successive rounds, respectively, 397 and 385 respondents ranked the questions by priority, then re-ranked the 40 questions with the highest mean priority score. High-priority questions related to antireflux surgery, the oncologic and immune effects of minimally invasive surgery, and morbid obesity. The question with the highest mean priority ranking was: "What is the best treatment (antireflux surgery, endoluminal therapy, or medication) for GERD?" The second highest-ranked question was: "Does minimally invasive surgery improve oncologic outcomes as compared with open surgery?" Other questions covered a broad range of research areas including clinical research, basic science research, education and evaluation, outcomes measurement, and health technology assessment. An iterative, anonymous group survey process was used to develop a research agenda for gastrointestinal and endoscopic surgery consisting of the 40 most important research questions in the field. This research agenda can be used by researchers and research-granting agencies to focus research activity in the areas most likely to have an impact on clinical care, and to appraise the relevance of scientific contributions.
Seewald, Stefan; Ang, Tiing Leong; Richter, Hugo; Teng, Karl Yu Kim; Zhong, Yan; Groth, Stefan; Omar, Salem; Soehendra, Nib
2012-01-01
To determine the immediate and long-term results of endoscopic drainage and necrosectomy for symptomatic pancreatic fluid collections. The data of 80 patients with symptomatic pancreatic fluid collections (mean diameter: 11.7 cm, range 3-20; pseudocysts: 24/80, abscess: 20/80, infected walled-off necrosis: 36/80) referred for endoscopic management from October 1997 to March 2008 were analyzed retrospectively. Endoscopic drainage techniques included endoscopic ultrasound (EUS)-guided aspiration (2/80), EUS-guided transenteric drainage (70/80) and non-EUS-guided drainage across a spontaneous transenteric fistula (8/80). Endoscopic necrosectomy was carried out in 49/80 (abscesses: 14/20; infected necrosis: 35/36). Procedural complications were bleeding (12/80), perforation (7/80), portal air embolism (1/80) and Ogilvie Syndrome (1/80). Initial technical success was achieved in 78/80 (97.5%) and clinical resolution of the collections was achieved endoscopically in 67/80 (83.8%), with surgery required in 13/80 (perforation: four; endoscopically inaccessible areas: two; inadequate drainage: seven). Within 6 months five patients required surgery due to recurrent fluid collections; over a mean follow up of 31 months, surgery was required in four more patients due to recurrent collections as a consequence of underlying pancreatic duct abnormalities that could not be treated endoscopically. The long-term success of endoscopic treatment was 58/80 (72.5%). Endoscopic drainage of symptomatic pancreatic fluid collections is safe and effective, with excellent immediate and long-term results. Endoscopic necrosectomy has a risk of serious complications. The underlying pancreatic duct abnormalities must be addressed to prevent recurrence of fluid collections. © 2011 The Authors. Digestive Endoscopy © 2011 Japan Gastroenterological Endoscopy Society.
Woo, Shanan; Walklin, Ryan; Ackermann, Travis; Lo, Sheng Wei; Shilton, Hamish; Pilgrim, Charles; Evans, Peter; Burnes, James; Croagh, Daniel
2018-05-10
Primary endoscopic and percutaneous drainage for pancreatic necrotic collections is increasingly used. We aim to compare the relative effectiveness of both modalities in reducing the duration and severity of illness by measuring their effects on systemic inflammatory response syndrome (SIRS). We retrospectively reviewed all cases of endoscopic and percutaneous drainage for pancreatic necrotic collections performed in 2011-2016 at two hospitals. We assessed the post-procedure length of hospital stay, reduction in C-reactive protein levels, resolution of SIRS, the complication rates, and the number of procedures required for resolution. Thirty-two patients were identified and 57 cases (36 endoscopic, 21 percutaneous) were included. There was no significant difference in C-reactive protein reduction between endoscopic and percutaneous drainage (69.5% vs 68.8%, P = 0.224). Resolution of SIRS was defined as the post-procedure normalization of white cell count (endoscopic vs percutaneous: 70.4% vs 64.3%, P = 0.477), temperature (endoscopic vs percutaneous: 93.3% vs 60.0%, P = 0.064), heart rate (endoscopic vs percutaneous: 56.0% vs 11.1%, P = 0.0234), and respiratory rate (endoscopic vs percutaneous: 83.3% vs 0.0%, P = 0.00339). Post-procedure length of hospital stay was 27 days with endoscopic drainage and 46 days with percutaneous drainage (P = 0.0183). Endoscopic drainage was associated with a shorter post-procedure length of hospital stay and a greater rate of normalization of SIRS parameters than percutaneous drainage, although only the effects on heart rate and respiratory rate reached statistical significance. Further studies are needed to establish which primary drainage modality is superior for pancreatic necrotic collections. © 2018 Japan Society for Endoscopic Surgery, Asia Endosurgery Task Force and John Wiley & Sons Australia, Ltd.
Leddy, Laura S.; Vanni, Alex J.; Wessells, Hunter; Voelzke, Bryan B.
2012-01-01
Purpose We examined the success of early endoscopic realignment of pelvic fracture associated urethral injury after blunt pelvic trauma. Materials and Methods A retrospective review was performed of patients with pelvic fracture associated urethral injury who underwent early endoscopic realignment using a retrograde or retrograde/antegrade approach from 2004 to 2010 at a Level 1 trauma center. Followup consisted of uroflowmetry, post-void residual and cystoscopic evaluation. Failure of early endoscopic realignment was defined as patients requiring urethral dilation, direct vision internal urethrotomy, posterior urethroplasty or self-catheterization after initial urethral catheter removal. Results A total of 19 consecutive patients (mean age 38 years) with blunt pelvic fracture associated urethral injury underwent early endoscopic realignment. Twelve cases of complete urethral disruption, 4 of incomplete disruption and 3 of indeterminate status were noted. Mean time to realignment was 2 days and mean duration of urethral catheterization after realignment was 53 days. One patient was lost to followup after early endoscopic realignment. Using an intent to treat analysis early endoscopic realignment failed in 15 of 19 patients (78.9%). Mean time to early endoscopic realignment failure after catheter removal was 79 days. The cases of early endoscopic realignment failure were managed with posterior urethroplasty (8), direct vision internal urethrotomy (3) and direct vision internal urethrotomy followed by posterior urethroplasty (3). Mean followup for the 4 patients considered to have undergone successful early endoscopic realignment was 2.1 years. Conclusions Early endoscopic realignment after blunt pelvic fracture associated urethral injury results in high rates of symptomatic urethral stricture requiring further operative treatment. Close followup after initial catheter removal is warranted, as the mean time to failure after early endoscopic realignment was 79 days in our cohort. PMID:22591965
DEVELOPMENT OF EMERGING TECHNOLOGIES WITHIN THE SITE PROGRAM
The Site Program is formed by five research programs: the Demonstration Program, the Emerging Technology Program, the Measurement and Monitoring Technology Development Program, the Innovative Technology Program, and the Technology Transfer Program. The Emerging Technology (ET) P...
Thota, Prashanthi N; Sada, Alaa; Sanaka, Madhusudhan R; Jang, Sunguk; Lopez, Rocio; Goldblum, John R; Liu, Xiuli; Dumot, John A; Vargo, John; Zuccarro, Gregory
2017-03-01
Patients with Barrett's esophagus (BE) and high-grade dysplasia (HGD) or intramucosal cancer (IMC) on endoscopic forceps biopsies are referred to endoscopic therapy even though forceps biopsies do not reflect the disease extent accurately. Endoscopic mucosal resection (EMR) and endoscopic ultrasound (EUS) are frequently used for staging prior to endoscopic therapy. Our aims were to evaluate: (1) if endoscopic forceps biopsies correlated with EMR histology in these patients; (2) the utility of EUS compared to EMR; and (3) if accuracy of EUS varied based on grade of differentiation of tumor. This is a retrospective review of patients referred to endoscopic therapy of BE with HGD or early esophageal adenocarcinoma (EAC) who underwent EMR from 2006 to 2011. Age, race, sex, length of Barrett's segment, hiatal hernia size, number of endoscopies and biopsy results and EUS findings were abstracted. A total of 151 patients underwent EMR. In 50 % (75/151) of patients, EMR histology was consistent with endoscopic forceps biopsy findings. EMR resulted in change in diagnosis with upstaging in 21 % (32/151) and downstaging in 29 % (44/151). In patients with HGD on EMR, EUS staging was T0 in 74.1 % (23/31) but upstaged in 25.8 % (8/31). In patients with IMC on EMR, EUS findings were T1a in 23.6 % (9/38), upstaged in 18.4 % (7/38) and downstaged in 57.8 % (22/38). EUS accurately identified EMR histology in all submucosal cancers. Grade of differentiation was reported in 24 cancers on EMR histology. There was no correlation between grade and EUS staging. EUS is of limited utility in accurate staging of BE patients with HGD or early EAC. Endoscopic forceps biopsy correlated with EMR findings in only 50 % of patients. Irrespective of the endoscopic forceps biopsy results, all BE patients with visible lesions should be referred to EMR.
Endoscopic approaches to treatment of achalasia
Friedel, David; Modayil, Rani; Iqbal, Shahzad; Grendell, James H.
2013-01-01
Endoscopic therapy for achalasia is directed at disrupting or weakening the lower esophageal sphincter (LES). The two most commonly utilized endoscopic interventions are large balloon pneumatic dilation (PD) and botulinum toxin injection (BTI). These interventions have been extensively scrutinized and compared with each other as well as with surgical disruption (myotomy) of the LES. PD is generally more effective in improving dysphagia in achalasia than BTI, with the latter reserved for infirm older people, and PD may approach treatment results attained with myotomy. However, PD may need to be repeated. Small balloon dilation and endoscopic stent placement for achalasia have only been used in select centers. Per oral endoscopic myotomy is a newer endoscopic modality that will likely change the treatment paradigm for achalasia. It arose from the field of natural orifice transluminal endoscopic surgery and represents a scarless endoscopic approach to Heller myotomy. This is a technique that requires extensive training and preparation and thus there should be rigorous accreditation and monitoring of outcomes to ensure safety and efficacy. PMID:23503707
Bisleri, Gianluigi; Giroletti, Laura; Hrapkowicz, Tomasz; Bertuletti, Martina; Zembala, Marian; Arieti, Mario; Muneretto, Claudio
2016-10-01
Despite the popularity of less invasive approaches for conduits procurement in coronary artery bypass graft surgery, concerns have been raised about the potential detrimental effects of the endoscopic technique when compared with the conventional "open" technique. Among 470 patients undergoing coronary surgery with the use of a radial artery conduit, a propensity score analysis was performed among those patients assigned either to an open technique (n = 82) or to an endoscopic approach (n = 82). Endoscopic harvesting was performed with a nonsealed system. The primary endpoint was cardiac-related mortality, and secondary endpoint was survival free from major cardiac and cerebrovascular adverse events. Moreover, hand and forearm sensory discomfort and forearm wound healing were also assessed. No conversion to the open technique occurred in patients undergoing endoscopic harvesting. No patients in either group showed hand ischemia; wound infection occurred only in the open group (open 7.3% versus endoscopic 0%, p = 0.007). Wound healing (Hollander scale) was considerably better in the endoscopic group (open 3.3, endoscopic 4.7; p < 0.001) as well as paresthesia at the latest follow-up (open 19.5% versus endoscopic 3.6%, p < 0.001). Pain (visual analog scale score) was significantly reduced with the endoscopic technique (open 3.2, endoscopic 1.2; p = 0.003). At 5 years of follow-up, freedom from cardiac-related mortality (open 96.3% ± 2.1% versus endoscopic 98.1% ± 1.8%; p = 0.448) as well as survival free from major cardiac and cerebrovascular adverse events (open 93.9% ± 2.6% versus endoscopic 93% ± 3.4%; p = 0.996) were similar among the groups. Endoscopic radial artery harvesting allows for incremental benefits in the short term in terms of improved cosmesis and reduced wound and neurologic complications, without yielding detrimental effects in terms of graft-related events at 5 years of follow-up. Copyright © 2016 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
The application of percutaneous endoscopic colostomy to the management of obstructed defecation.
Heriot, A G; Tilney, H S; Simson, J N L
2002-05-01
We describe the case of a 52-year woman with a 17-year history of obstructed defecation in whom all other standard treatments had failed and the patient had refused a colostomy. Her symptoms were controlled by percutaneous endoscopic colostomy with antegrade colonic irrigation. A percutaneous endoscopic colostomy tube was placed in the sigmoid colon endoscopically using a colonoscope and the patient irrigated two liters of water through the percutaneous endoscopic colostomy twice each day and was able to successfully evacuate her rectum without excess straining or discomfort. Percutaneous endoscopic colostomy is an alternative option to colostomy in the management of obstructed defecation.
Micromotor endoscope catheter for in vivo, ultrahigh-resolution optical coherence tomography
NASA Astrophysics Data System (ADS)
Herz, P. R.; Chen, Y.; Aguirre, A. D.; Schneider, K.; Hsiung, P.; Fujimoto, J. G.; Madden, K.; Schmitt, J.; Goodnow, J.; Petersen, C.
2004-10-01
A distally actuated, rotational-scanning micromotor endoscope catheter probe is demonstrated for ultrahigh-resolution in vivo endoscopic optical coherence tomography (OCT) imaging. The probe permits focus adjustment for visualization of tissue morphology at varying depths with improved transverse resolution compared with standard OCT imaging probes. The distal actuation avoids nonuniform scanning motion artifacts that are present with other probe designs and can permit a wider range of imaging speeds. Ultrahigh-resolution endoscopic imaging is demonstrated in a rabbit with <4-µm axial resolution by use of a femtosecond Crforsterite laser light source. The micromotor endoscope catheter probe promises to improve OCT imaging performance in future endoscopic imaging applications.
Extended Endoscopic and Open Sinus Surgery for Refractory Chronic Rhinosinusitis.
Eloy, Jean Anderson; Marchiano, Emily; Vázquez, Alejandro
2017-02-01
This review discusses extended endoscopic and open sinus surgery for refractory chronic rhinosinusitis. Extended maxillary sinus surgery including endoscopic maxillary mega-antrostomy, endoscopic modified medial maxillectomy, and inferior meatal antrostomy are described. Total/complete ethmoidectomy with mucosal stripping (nasalization) is discussed. Extended endoscopic sphenoid sinus procedures as well as their indications and potential risks are reviewed. Extended endoscopic frontal sinus procedures, such the modified Lothrop procedure, are described. Extended open sinus surgical procedures, such as the Caldwell-Luc approach, frontal sinus trephine procedure, external frontoethmoidectomy, frontal sinus osteoplastic flap with or without obliteration, and cranialization, are discussed. Copyright © 2016 Elsevier Inc. All rights reserved.
Improving the Endoscopic Detection Rate in Patients with Early Gastric Cancer
2015-01-01
Endoscopists should ideally possess both sufficient knowledge of the endoscopic gastrointestinal disease findings and an appropriate attitude. Before performing endoscopy, the endoscopist must identify several risk factors of gastric cancer, including the patient's age, comorbidities, and drug history, a family history of gastric cancer, previous endoscopic findings of atrophic gastritis or intestinal metaplasia, and a history of previous endoscopic treatments. During endoscopic examination, the macroscopic appearance is very important for the diagnosis of early gastric cancer; therefore, the endoscopist should have a consistent and organized endoscope processing technique and the ability to comprehensively investigate the entire stomach, even blind spots. PMID:26240801
Quantitative endoscopy: initial accuracy measurements.
Truitt, T O; Adelman, R A; Kelly, D H; Willging, J P
2000-02-01
The geometric optics of an endoscope can be used to determine the absolute size of an object in an endoscopic field without knowing the actual distance from the object. This study explores the accuracy of a technique that estimates absolute object size from endoscopic images. Quantitative endoscopy involves calibrating a rigid endoscope to produce size estimates from 2 images taken with a known traveled distance between the images. The heights of 12 samples, ranging in size from 0.78 to 11.80 mm, were estimated with this calibrated endoscope. Backup distances of 5 mm and 10 mm were used for comparison. The mean percent error for all estimated measurements when compared with the actual object sizes was 1.12%. The mean errors for 5-mm and 10-mm backup distances were 0.76% and 1.65%, respectively. The mean errors for objects <2 mm and > or =2 mm were 0.94% and 1.18%, respectively. Quantitative endoscopy estimates endoscopic image size to within 5% of the actual object size. This method remains promising for quantitatively evaluating object size from endoscopic images. It does not require knowledge of the absolute distance of the endoscope from the object, rather, only the distance traveled by the endoscope between images.
Management of Inflammatory Fluid Collections and Walled-Off Pancreatic Necrosis.
Shah, Apeksha; Denicola, Richard; Edirisuriya, Cynthia; Siddiqui, Ali A
2017-12-01
Pancreatic fluid collections are a frequent complication of acute pancreatitis. The revised Atlanta criterion classifies chronic fluid collections into pseudocysts and walled-off pancreatic necrosis (WON). Symptomatic PFCs require drainage options that include surgical, percutaneous, or endoscopic approaches. With the advent of newer and more advanced endoscopic tools and expertise, minimally invasive endoscopic drainage has now become the preferred approach. An endoscopic ultrasonography (EUS)-guided approach for pancreatic fluid collection drainage is now the preferred endoscopic approach. Both plastic stents and metal stents are efficacious and safe; however, metal stents may offer an advantage, especially in infected pseudocysts and in WON. Direct endoscopic necrosectomy is often required in WON. Lumen apposing metal stents allow for direct endoscopic necrosectomy and debridement through the stent lumen and are now preferred in these patients. Endoscopic retrograde cholangiopancreatography with pancreatic duct exploration should be performed concurrent to PFC drainage in patients with suspected PD disruption. PD disruption is associated with an increased severity of pancreatitis, an increased risk of recurrent attacks of pancreatitis and long-term complications, and a decreased rate of PFC resolution after drainage. Ideally, pancreatic ductal disruption should be bridged with endoscopic stenting.
Future Development of Endoscopic Accessories for Endoscopic Submucosal Dissection
Jang, Jae-Young
2017-01-01
Endoscopic submucosal dissection (ESD) has recently been accepted as a standard treatment for patients with early gastric cancer (EGC), without lymph node metastases. Given the rise in the number of ESDs being performed, new endoscopic accessories are being developed and existing accessories modified to facilitate the execution of ESD and reduce complication rates. This paper examines the history underlying the development of these new endoscopic accessories and indicates future directions for the development of these accessories. PMID:28609819
Huikai, Li; Enqiang, Linghu
2013-01-01
It is of vital importance to determine the depth of lesions to be treated by endoscopic submucosal dissection. This study aimed to compare the accuracy of using hot biopsy forceps method with endoscopic ultrasonography for determination of the depth of gastric epithelial neoplasia. Hot biopsy forceps method and/or endoscopic ultrasonography were used to determine the depth of lesions in 27 patients. With hot biopsy forceps method, we assumed a lesion completely lifted up by a hot biopsy forceps to be confined to the mucosal layer, and one partly lifted up to be located beyond the mucosal layer. The accuracy of hot biopsy forceps method and endoscopic ultrasonography in determining the depth of lesions were compared. Of the 27 patients, 25 underwent endoscopic submucosal dissection and 2 underwent surgery. The total accuracy of hot biopsy forceps method in determining the depth of lesions was 92.6% and that of endoscopic ultrasonography was 81.8%. Overestimation of hot biopsy forceps method and endoscopic ultrasonography were 3.7% vs. 13.6%, respectively. The sensitivity and the specificity of hot biopsy forceps method were 95.5% and 80.0% and those of EUS were 83.3% and 75.0%. Hot biopsy forceps method has a trend towards higher accuracy and lower overestimation than endoscopic ultrasonography.
Chan, Jason Y K; Leung, Iris; Navarro-Alarcon, David; Lin, Weiyang; Li, Peng; Lee, Dennis L Y; Liu, Yun-hui; Tong, Michael C F
2016-03-01
To evaluate the feasibility of a unique prototype foot-controlled robotic-enabled endoscope holder (FREE) in functional endoscopic sinus surgery. Cadaveric study. Using human cadavers, we investigated the feasibility, advantages, and disadvantages of the robotic endoscope holder in performing endoscopic sinus surgery with two hands in five cadaver heads, mimicking a single nostril three-handed technique. The FREE robot is relatively easy to use. Setup was quick, taking less than 3 minutes from docking the robot at the head of the bed to visualizing the middle meatus. The unit is also relatively small, takes up little space, and currently has four degrees of freedom. The learning curve for using the foot control was short. The use of both hands was not hindered by the presence of the endoscope in the nasal cavity. The tremor filtration also aided in the smooth movement of the endoscope, with minimal collisions. The FREE endoscope holder in an ex-vivo cadaver test corroborated the feasibility of the robotic prototype, which allows for a two-handed approach to surgery equal to a single nostril three-handed technique without the holder that may reduce operating time. Further studies will be needed to evaluate its safety profile and use in other areas of endoscopic surgery. NA. Laryngoscope, 126:566-569, 2016. © 2015 The American Laryngological, Rhinological and Otological Society, Inc.
78 FR 40098 - Emerging Technology and Research Advisory Committee;
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-03
... DEPARTMENT OF COMMERCE Bureau of Industry and Security Emerging Technology and Research Advisory Committee; Notice of Partially Closed Meeting The Emerging Technology and Research Advisory Committee (ETRAC... Assistant Secretary for Export Administration on emerging technology and research activities, including...
Endoscopic Management of Foreign Bodies in the Gastrointestinal Tract: A Review of the Literature
Andrade, Javier; Twersky, Yitzhak; Iqbal, Shahzad
2016-01-01
Foreign body ingestion is a common diagnosis that presents in emergency departments throughout the world. Distinct foreign bodies predispose to particular locations of impaction in the gastrointestinal tract, commonly meat boluses in the esophagus above a preexisting esophageal stricture or ring in adults and coins in children. Several other groups are at high risk of foreign body impaction, mentally handicapped individuals or those with psychiatric illness, abusers of drugs or alcohol, and the geriatric population. Patients with foreign body ingestion typically present with odynophagia, dysphagia, sensation of having an object stuck, chest pain, and nausea/vomiting. The majority of foreign bodies pass through the digestive system spontaneously without causing any harm, symptoms, or necessitating any further intervention. A well-documented clinical history and thorough physical exam is critical in making the diagnosis, if additional modalities are needed, a CT scan and diagnostic endoscopy are generally the preferred modalities. Various tools can be used to remove foreign bodies, and endoscopic treatment is safe and effective if performed by a skilled endoscopist. PMID:27807447
Schmidt, Arthur; Riecken, Bettina; Damm, Michael; Cahyadi, Oscar; Bauder, Markus; Caca, Karel
2014-09-01
Over-the-scope clips (OTSCs; Ovesco Endoscopy, Tübingen, Germany) are extensively used for treatment of gastrointestinal perforations, leakages, fistulas, and bleeding. In this report, a new method of removing OTSCs using a prototype bipolar cutting device is described. A total of 11 patients underwent endoscopic removal of an OTSC. The OTSC was cut at two opposing sites by a prototype device (DC ClipCutter; Ovesco Endoscopy). The remaining clip fragments were extracted using a standard forceps. Mean procedure time was 47 minutes (range 35 - 75 minutes). Cutting of the OTSC at two opposing sites was successful in all cases (100 %). Complete retrieval of all clip fragments was possible in 10 patients (91 %). The overall success rate for cutting and complete removal of the clip was 91 %. No major complications were observed. Removal of OTSCs with the prototype device was feasible and effective. The device may be valuable for OTSC removal in emergency as well as elective indications. © Georg Thieme Verlag KG Stuttgart · New York.
Osera, Shozo; Yano, Tomonori; Odagaki, Tomoyuki; Oono, Yasuhiro; Ikematsu, Hiroaki; Ohtsu, Atsushi; Kaneko, Kazuhiro
2015-10-01
Percutaneous endoscopic gastrostomy (PEG) using the direct method is generally indicated for cancer patients. However, there are little available data about peritonitis related to this method. The aim of this retrospective analysis was to assess peritonitis related to PEG using the direct method in patients with cancer. We assessed the prevalence of peritonitis and the relationship between peritonitis and patients' backgrounds, as well as the clinical course after peritonitis. Between December 2008 and December 2011, peritonitis was found in 9 (2.1 %) of 421 patients. Of the 9 patients with peritonitis, 4 had received PEG prior to chemoradiotherapy. Emergency surgical drainage was required in 1 patient, and the remaining 8 recovered with conservative treatment. Peritonitis occurred within 8 days of PEG for 8 of the 9 patients and occurred within 2 days of suture removal for 4 of the 9 patients. Peritonitis related to PEG using the direct method was less frequent for cancer patients. Peritonitis tended to occur within a few days after removal of securing suture and in patients with palliative stage.
Tang, Shou-Jiang; Rivas, Homero; Tang, Linda; Lara, Luis F; Sreenarasimhaiah, Jayaprakash; Rockey, Don C
2007-09-01
Roux-en-Y gastric bypass (RYGBP) is the most commonly performed bariatric operation in the USA. In the early postoperative stage, gastrointestinal (GI) bleeding is an infrequent but potentially serious complication that usually results from bleeding at the gastrojejunostomy staple-line. Observant management with transfusion for stable patients and surgical exploration for unstable patients is typically recommended for early GI bleeding. We hypothesized that use of endoclips, which do not cause thermal injury to the surrounding tissues (or anastomosis), may be preferable to thermal approaches which could cause tissue injury. We report 2 cases of early GI bleeding after RYGBP that were successfully managed with endoclip application to bleeding lesions. Emergent endoscopy was performed, and major stigmata such as active spurting vessel and adherent clot were noted at the gastrojejunostomy staple-lines. Endoscopic hemostasis using endoclips was readily applied to bleeding lesions at staple-lines. Primary hemostasis was achieved, and there was no recurrent bleeding or complication. We conclude that therapeutic endoscopy can be performed safely for early bleeding after RYGBP. In patients with early bleeding after RYGBP, use of endoclips is mechanistically preferable to other options.
Pelletier, Valerie; Winter, Kelly; Albatineh, Ahmed N.
2013-01-01
Objectives. Physician recommendation plays a crucial role in receiving endoscopic screening for colorectal cancer (CRC). This study explored factors associated with racial/ethnic differences in rates of screening recommendation. Methods. Data on 5900 adults eligible for endoscopic screening were obtained from the National Health Interview Survey. Odds ratios of receiving an endoscopy recommendation were calculated for selected variables. Planned, sequenced logistic regressions were conducted to examine the extent to which socioeconomic and health care variables account for racial/ethnic disparities in recommendation rates. Results. Differential rates were observed for CRC screening and screening recommendations among racial/ethnic groups. Compared with Whites, Hispanics were 34% less likely (P < .01) and Blacks were 26% less likely (P < .05) to receive this recommendation. The main predictors that emerged in sequenced analysis were education for Hispanics and Blacks and income for Blacks. After accounting for the effects of usual source of care, insurance coverage, and education, the disparity reduced and became statistically insignificant. Conclusions. Socioeconomic status and access to health care may explain major racial/ethnic disparities in CRC screening recommendation rates. PMID:23678899
Kato, Shin; Kuwatani, Masaki; Sugiura, Ryo; Sano, Itsuki; Kawakubo, Kazumichi; Ono, Kota; Sakamoto, Naoya
2017-08-11
The effect of endoscopic sphincterotomy prior to endoscopic biliary stenting to prevent post-endoscopic retrograde cholangiopancreatography pancreatitis remains to be fully elucidated. The aim of this study is to prospectively evaluate the non-inferiority of non-endoscopic sphincterotomy prior to stenting for naïve major duodenal papilla compared with endoscopic sphincterotomy prior to stenting in patients with biliary stricture. We designed a multicentre randomised controlled trial, for which we will recruit 370 patients with biliary stricture requiring endoscopic biliary stenting from 26 high-volume institutions in Japan. Patients will be randomly allocated to the endoscopic sphincterotomy group or the non-endoscopic sphincterotomy group. The main outcome measure is the incidence of pancreatitis within 2 days of initial transpapillary biliary drainage. Data will be analysed on completion of the study. We will calculate the 95% confidence intervals (CIs) of the incidence of pancreatitis in each group and analyse weather the difference in both groups with 95% CIs is within the non-inferiority margin (6%) using the Wald method. This study has been approved by the institutional review board of Hokkaido University Hospital (IRB: 016-0181). Results will be submitted for presentation at an international medical conference and published in a peer-reviewed journal. The University Hospital Medical Information Network ID: UMIN000025727 Pre-results. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Monitoring of endoscope reprocessing with an adenosine triphosphate (ATP) bioluminescence method.
Parohl, Nina; Stiefenhöfer, Doris; Heiligtag, Sabine; Reuter, Henning; Dopadlik, Dana; Mosel, Frank; Gerken, Guido; Dechêne, Alexander; Heintschel von Heinegg, Evelyn; Jochum, Christoph; Buer, Jan; Popp, Walter
2017-01-01
Background: The arising challenges over endoscope reprocessing quality proposes to look for possibilities to measure and control the process of endoscope reprocessing. Aim: The goal of this study was to evaluate the feasibility of monitoring endoscope reprocessing with an adenosine triphosphate (ATP) based bioluminescence system. Methods: 60 samples of eight gastroscopes have been assessed from routine clinical use in a major university hospital in Germany. Endoscopes have been assessed with an ATP system and microbial cultures at different timepoints during the reprocessing. Findings: After the bedside flush the mean ATP level in relative light units (RLU) was 19,437 RLU, after the manual cleaning 667 RLU and after the automated endoscope reprocessor (AER) 227 RLU. After the manual cleaning the mean total viable count (TVC) per endoscope was 15.3 CFU/10 ml, and after the AER 5.7 CFU/10 ml. Our results show that there are reprocessing cycles which are not able to clean a patient used endoscope. Conclusion: Our data suggest that monitoring of flexible endoscope with ATP can identify a number of different influence factors, like the endoscope condition and the endoscopic procedure, or especially the quality of the bedside flush and manual cleaning before the AER. More process control is one option to identify and improve influence factors to finally increase the overall reprocessing quality, best of all by different methods. ATP measurement seems to be a valid technique that allows an immediate repeat of the manual cleaning if the ATP results after manual cleaning exceed the established cutoff of 200 RLU.
NASA Astrophysics Data System (ADS)
Gómez-García, Pablo Aurelio; Arranz, Alicia; Fresno, Manuel; Desco, Manuel; Mahmood, Umar; Vaquero, Juan José; Ripoll, Jorge
2015-06-01
Endoscopy is frequently used in the diagnosis of several gastro-intestinal pathologies as Crohn disease, ulcerative colitis or colorectal cancer. It has great potential as a non-invasive screening technique capable of detecting suspicious alterations in the intestinal mucosa, such as inflammatory processes. However, these early lesions usually cannot be detected with conventional endoscopes, due to lack of cellular detail and the absence of specific markers. Due to this lack of specificity, the development of new endoscopy technologies, which are able to show microscopic changes in the mucosa structure, are necessary. We here present a confocal endomicroscope, which in combination with a wide field fluorescence endoscope offers fast and specific macroscopic information through the use of activatable probes and a detailed analysis at cellular level of the possible altered tissue areas. This multi-modal and multi-scale imaging module, compatible with commercial endoscopes, combines near-infrared fluorescence (NIRF) measurements (enabling specific imaging of markers of disease and prognosis) and confocal endomicroscopy making use of a fiber bundle, providing a cellular level resolution. The system will be used in animal models exhibiting gastro-intestinal diseases in order to analyze the use of potential diagnostic markers in colorectal cancer. In this work, we present in detail the set-up design and the software implementation in order to obtain simultaneous RGB/NIRF measurements and short confocal scanning times.
A research agenda for the European Association for Endoscopic Surgeons (EAES).
Francis, Nader; Kazaryan, Airazat M; Pietrabissa, Andrea; Goitein, David; Yiannakopoulou, Eugenia; Agresta, Ferdinando; Khatkov, Igor; Schulze, Svend; Arulampalam, Tan; Tomulescu, Victor; Kim, Young-Woo; Targarona, Eduardo Mª; Zaninotto, Giovanni
2017-05-01
The European Association of Endoscopic Surgeons (EAES) conducted this study aiming to identify the top research questions which are relevant to surgeons in Minimal Access Surgery (MAS). This is in order to promote and link research questions to the current clinical practice in MAS in Europe. Using a systematic methodology, (modified Delphi), the EAES members and leadership teams were surveyed to obtain consensus on the top research priorities in MAS. The responses were categorized and redistributed to the membership to rate the level of importance of each research question. The data were reported as the weighted average score with a scale from 1 (lowest agreement) to 5 (highest agreement). In total, 324 of 2580 (12.5%) of the EAES members and the leaders responded to the survey and contributed to the final consensus. The ranked responses over the 80th percentile identified 39 research priorities with rating ranged from 4.22 to 3.67. The top five highest ranking research priorities in the EAES were centered on improving training in MAS, laparoscopic surgery for benign upper gastrointestinal conditions, integration of novel technology in OR, translational and basic science research in bariatric surgery and investigating the role of MAS in rectal cancer. An EAES research agenda was developed using a systematic methodology and can be used to focus MAS research. This study was commissioned by the European Association for Endoscopic Surgery (EAES).
Development of Bariatric and Metabolic Endoscopy
Li, Shi-Han; Wang, Yong-Jun; Zhang, Shu-Tian
2018-01-01
Objective: With the evolution of society and changes in human lifestyle, obesity is becoming increasingly prevalent worldwide, and obesity-related comorbidities such as diabetes, hyperlipidemia, hypertension, and coronary heart disease are more common. As a result, new devices and methods for bariatric and metabolic endoscopy are being developed for clinical use, offering new options for patients. This review discussed the progress in bariatric and metabolic endoscopy. Data Sources: This review was based on data in articles published in the PubMed database up to September 2017, with the following keywords: “obesity”, “endoscopy”, “weight loss”, and “metabolism”. Study Selection: Original articles about various endoscopic methods of weight loss and other reviews of bariatric and metabolic endoscopy were included and analyzed. Results: The technology of bariatric and metabolic endoscopy has advanced rapidly in recent years. The intragastric balloon (IGB), with its comparatively long period of development, is the most mature and widely used instrument. Multiple new endoscopic devices have been created in recent years, with different targets to achieve weight loss. Despite the proliferation of new devices, the lack of clinical data results in a shortage of clinical experience and instruction in the use of this new equipment. Conclusions: Bariatric and metabolic endoscopy would help obese people lose weight or prepare for bariatric surgery and hopefully alleviate some of the complications of bariatric procedures. Adequate studies and data are still needed for the new endoscopic devices. PMID:29271386
Excitation-scanning hyperspectral imaging system for microscopic and endoscopic applications
NASA Astrophysics Data System (ADS)
Mayes, Sam A.; Leavesley, Silas J.; Rich, Thomas C.
2016-04-01
Current microscopic and endoscopic technologies for cancer screening utilize white-light illumination sources. Hyper-spectral imaging has been shown to improve sensitivity while retaining specificity when compared to white-light imaging in both microscopy and in vivo imaging. However, hyperspectral imaging methods have historically suffered from slow acquisition times due to the narrow bandwidth of spectral filters. Often minutes are required to gather a full image stack. We have developed a novel approach called excitation-scanning hyperspectral imaging that provides 2-3 orders of magnitude increased signal strength. This reduces acquisition times significantly, allowing for live video acquisition. Here, we describe a preliminary prototype excitation-scanning hyperspectral imaging system that can be coupled with endoscopes or microscopes for hyperspectral imaging of tissues and cells. Our system is comprised of three subsystems: illumination, transmission, and imaging. The illumination subsystem employs light-emitting diode arrays to illuminate at different wavelengths. The transmission subsystem utilizes a unique geometry of optics and a liquid light guide. Software controls allow us to interface with and control the subsystems and components. Digital and analog signals are used to coordinate wavelength intensity, cycling and camera triggering. Testing of the system shows it can cycle 16 wavelengths at as fast as 1 ms per cycle. Additionally, more than 18% of the light transmits through the system. Our setup should allow for hyperspectral imaging of tissue and cells in real time.
Wan, D-L; Li, M-X; Bao, L; Zhang, L-L; Zhang, L; Chen, Q-Y; Lin, S-Z
2018-04-01
With the continuous improvement of liver transplantation technology, the survival rate of liver transplantation has been improved, but recurrent or de novo malignancy remains one of the major factors affecting the long-term survival of liver transplant recipients. A 45-year-old Chinese man had a plastic biliary stent placed on account of biliary anastomotic stenosis after 3 years of piggyback liver transplantation. He came to our hospital because of recurrent fever and jaundice for 2 weeks, and his carcinoembryonic antigen-199 had increased. The patient's duodenal papillary was cauliflower-like at endoscopic retrograde cholangiopancreatography to replace the biliary stent. He was initially suspected of having duodenal papillary carcinoma after liver transplantation. However, the pathology from endoscopic retrograde cholangiopancreatography and endoscopic ultrasound-guided biopsy showed inflammation. While awaiting the result of biopsy, his CA-199 decreased significantly after anti-infection and symptomatic treatment. The patient was diagnosed with biliary anastomotic stenosis and duodenal papillitis. He was discharged uneventfully; to date, there is no evidence of malignant tumor. We report this case to provide helpful information to clinicians about the management of the duodenal papilla cauliflower-like neoplasm after liver transplantation, which should be considered as inflammatory first. Perhaps our view can avoid the risk of bringing an excessive medical treatment and unnecessary economic burden to patients and their families. Copyright © 2018 Elsevier Inc. All rights reserved.
Pulvirenti, Elia; Toro, Adriana; Di Carlo, Isidoro
2010-01-01
Natural Orifice Transluminal Endoscopic Surgery (NOTES) is an innovative approach in which a flexible endoscope enters the abdominal cavity via the transesophageal, transgastric, transcolonic, transvaginal or transvescical route, combining the technique of minimally invasive surgery with flexible endoscopy. Several groups have described different modifications by using flexible endoscopes with different levels of laparoscopic assistance. Transvaginal cholecystectomy (TVC) consists in accessing the abdominal cavity through a posterior colpotomy and using the vaginal incision as a visual or operative port. An increasing interest has arisen around the TVC; nevertheless, the most common and highlighted concern is about the lack of specific instruments dedicated to the vaginal access route. TVC should be distinguished between "pure", in which the entire operation is performed through the transvaginal route, and "hybrid", in which the colpotomy represents only a support to introduce instruments and the operation is performed mainly by the classic transabdominal-introduced instruments. Although this new technique seems very appealing for patients, on the other hand it is very challenging for the surgeon because of the difficulties related to the mode of access, the limited technology currently available and the risk of complications related to the organ utilized for access. In this brief review all the most recent advancements in the field of TVC's techniques and instrumentations are listed and discussed.
Soft Robotic Manipulator for Improving Dexterity in Minimally Invasive Surgery.
Diodato, Alessandro; Brancadoro, Margherita; De Rossi, Giacomo; Abidi, Haider; Dall'Alba, Diego; Muradore, Riccardo; Ciuti, Gastone; Fiorini, Paolo; Menciassi, Arianna; Cianchetti, Matteo
2018-02-01
Combining the strengths of surgical robotics and minimally invasive surgery (MIS) holds the potential to revolutionize surgical interventions. The MIS advantages for the patients are obvious, but the use of instrumentation suitable for MIS often translates in limiting the surgeon capabilities (eg, reduction of dexterity and maneuverability and demanding navigation around organs). To overcome these shortcomings, the application of soft robotics technologies and approaches can be beneficial. The use of devices based on soft materials is already demonstrating several advantages in all the exploitation areas where dexterity and safe interaction are needed. In this article, the authors demonstrate that soft robotics can be synergistically used with traditional rigid tools to improve the robotic system capabilities and without affecting the usability of the robotic platform. A bioinspired soft manipulator equipped with a miniaturized camera has been integrated with the Endoscopic Camera Manipulator arm of the da Vinci Research Kit both from hardware and software viewpoints. Usability of the integrated system has been evaluated with nonexpert users through a standard protocol to highlight difficulties in controlling the soft manipulator. This is the first time that an endoscopic tool based on soft materials has been integrated into a surgical robot. The soft endoscopic camera can be easily operated through the da Vinci Research Kit master console, thus increasing the workspace and the dexterity, and without limiting intuitive and friendly use.
21 CFR 882.1480 - Neurological endoscope.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Neurological endoscope. 882.1480 Section 882.1480...) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Diagnostic Devices § 882.1480 Neurological endoscope. (a) Identification. A neurological endoscope is an instrument with a light source used to view the inside of the...
21 CFR 882.1480 - Neurological endoscope.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Neurological endoscope. 882.1480 Section 882.1480...) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Diagnostic Devices § 882.1480 Neurological endoscope. (a) Identification. A neurological endoscope is an instrument with a light source used to view the inside of the...
[The development of endoscope workstation].
Qi, L; Qi, L; Qiou, Q J; Yu, Q L
2001-01-01
This paper introduces an endoscope workstation, which solved the weak points of multimedia endoscope database used by most hospitals. The endoscope workstation was built on pedal-switch and NTFS file system. This paper also Introduces how to make program optimal and quick inputting. The workstation has promoted the efficiency of the doctor's operation.
Endoscopic mucosal resection of colonic lesions: current applications and future prospects.
Poppers, David M; Haber, Gregory B
2008-05-01
The introduction of submucosal fluid injection has remarkably extended the range of endoscopically resectable polyps. The limiting factor for endoscopic resection is not polyp size, but polyp depth. Endoscopic ultrasound is a useful adjunctive diagnostic tool to assess the depth of invasion. The success of are section ultimately depends on pathologic confirmation of a benign nature of this lesion or of a cancer limited to the mucosa. Selected well-differentiated cancers without lymphovascular invasion of the superficial submucosa can be successfully resected endoscopically.
Endoscopic full-thickness resection: Current status
Schmidt, Arthur; Meier, Benjamin; Caca, Karel
2015-01-01
Conventional endoscopic resection techniques such as endoscopic mucosal resection or endoscopic submucosal dissection are powerful tools for treatment of gastrointestinal neoplasms. However, those techniques are restricted to superficial layers of the gastrointestinal wall. Endoscopic full-thickness resection (EFTR) is an evolving technique, which is just about to enter clinical routine. It is not only a powerful tool for diagnostic tissue acquisition but also has the potential to spare surgical therapy in selected patients. This review will give an overview about current EFTR techniques and devices. PMID:26309354
Endoscopic full-thickness resection: Current status.
Schmidt, Arthur; Meier, Benjamin; Caca, Karel
2015-08-21
Conventional endoscopic resection techniques such as endoscopic mucosal resection or endoscopic submucosal dissection are powerful tools for treatment of gastrointestinal neoplasms. However, those techniques are restricted to superficial layers of the gastrointestinal wall. Endoscopic full-thickness resection (EFTR) is an evolving technique, which is just about to enter clinical routine. It is not only a powerful tool for diagnostic tissue acquisition but also has the potential to spare surgical therapy in selected patients. This review will give an overview about current EFTR techniques and devices.
Upper gastrointestinal bleeding - state of the art.
Szura, Mirosław; Pasternak, Artur
2014-01-01
Upper gastrointestinal (GI) bleeding is a condition requiring immediate medical intervention, with high associated mortality exceeding 10%. The most common cause of upper GI bleeding is peptic ulcer disease, which largely corresponds to the intake of NSAIDs and Helicobacter pylori infection. Endoscopy is the essential tool for the diagnosis and treatment of active upper GI hemorrhage. Endoscopic therapy together with proton pump inhibitors and eradication of Helicobacter pylori significantly reduces rebleeding rates, mortality and number of emergency surgical interventions. This paper presents contemporary data on the diagnosis and treatment of upper gastrointestinal bleeding.
Nailing Digital Jelly to a Virtual Tree: Tracking Emerging Technologies for Learning
ERIC Educational Resources Information Center
Serim, Ferdi; Schrock, Kathy
2008-01-01
Reliable information on emerging technologies for learning is as vital as it is difficult to come by. To meet this need, the International Society for Technology in Education organized the Emerging Technologies Task Force. Its goal is to create a database of contributions from educators highlighting their use of emerging technologies to support…
Federal Register 2010, 2011, 2012, 2013, 2014
2011-09-02
... DEPARTMENT OF COMMERCE Bureau of Industry and Security Emerging Technology and Research Advisory Committee; Notice of Partially Closed Meeting The Emerging Technology and Research Advisory Committee (ETRAC... the Assistant Secretary for Export Administration on emerging technology and research activities...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-26
... Introductions. 2. Member Discussion Methodology Options for Identifying Emerging Technologies. 3. Public... DEPARTMENT OF COMMERCE Bureau of Industry and Security Emerging Technology and Research Advisory Committee; Notice of Partially Closed Meeting The Emerging Technology and Research Advisory Committee (ETRAC...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-02-23
... DEPARTMENT OF COMMERCE Bureau of Industry and Security Emerging Technology and Research Advisory Committee; Notice of Partially Closed Meeting The Emerging Technology and Research Advisory Committee (ETRAC... the Assistant Secretary for Export Administration on emerging technology and research activities...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-07-16
... DEPARTMENT OF COMMERCE Bureau of Industry and Security Emerging Technology and Research Advisory Committee; Notice of Partially Closed Meeting The Emerging Technology and Research Advisory Committee (ETRAC... the Assistant Secretary for Export Administration on emerging technology and research activities...
Micromotor endoscope catheter for in vivo, ultrahigh-resolution optical coherence tomography.
Herz, P R; Chen, Y; Aguirre, A D; Schneider, K; Hsiung, P; Fujimoto, J G; Madden, K; Schmitt, J; Goodnow, J; Petersen, C
2004-10-01
A distally actuated, rotational-scanning micromotor endoscope catheter probe is demonstrated for ultrahigh-resolution in vivo endoscopic optical coherence tomography (OCT) imaging. The probe permits focus adjustment for visualization of tissue morphology at varying depths with improved transverse resolution compared with standard OCT imaging probes. The distal actuation avoids nonuniform scanning motion artifacts that are present with other probe designs and can permit a wider range of imaging speeds. Ultrahigh-resolution endoscopic imaging is demonstrated in a rabbit with <4-microm axial resolution by use of a femtosecond Cr:forsterite laser light source. The micromotor endoscope catheter probe promises to improve OCT imaging performance in future endoscopic imaging applications.
Endoscopic findings following retroperitoneal pancreas transplantation.
Pinchuk, Alexey V; Dmitriev, Ilya V; Shmarina, Nonna V; Teterin, Yury S; Balkarov, Aslan G; Storozhev, Roman V; Anisimov, Yuri A; Gasanov, Ali M
2017-07-01
An evaluation of the efficacy of endoscopic methods for the diagnosis and correction of surgical and immunological complications after retroperitoneal pancreas transplantation. From October 2011 to March 2015, 27 patients underwent simultaneous retroperitoneal pancreas-kidney transplantation (SPKT). Diagnostic oesophagogastroduodenoscopy (EGD) with protocol biopsy of the donor and recipient duodenal mucosa and endoscopic retrograde pancreatography (ERP) were performed to detect possible complications. Endoscopic stenting of the main pancreatic duct with plastic stents and three-stage endoscopic hemostasis were conducted to correct the identified complications. Endoscopic methods showed high efficiency in the timely diagnosis and adequate correction of complications after retroperitoneal pancreas transplantation. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Endoscopic Therapy in Crohn's Disease: Principle, Preparation, and Technique.
Chen, Min; Shen, Bo
2015-09-01
Stricture and fistula are common complications of Crohn's disease. Endoscopic balloon dilation and needle-knife stricturotomy has become a valid treatment option for Crohn's disease-associated strictures. Endoscopic therapy is also increasingly used in Crohn's disease-associated fistula. Preprocedural preparations, including routine laboratory testing, imaging examination, anticoagulant management, bowel cleansing and proper sedation, are essential to ensure a successful and safe endoscopic therapy. Adverse events, such as perforation and excessive bleeding, may occur during endoscopic intervention. The endoscopist should be well trained, always be cautious, anticipate for possible procedure-associated complications, be prepared for damage control during endoscopy, and have surgical backup ready. In this review, we discuss the principle, preparation, techniques of endoscopic therapy, as well as the prevention and management of endoscopic procedure-associated complications. We propose that inflammatory bowel disease endoscopy may be a part of training for "super" gastroenterology fellows, i.e., those seeking a career in advanced endoscopy or in inflammatory bowel disease.
Endoscopic versus open bursectomy of lateral malleolar bursitis.
Choi, Jae Hyuck; Lee, Kyung Tai; Lee, Young Koo; Kim, Dong Hyun; Kim, Jeong Ryoul; Chung, Woo Chull; Cha, Seung Do
2012-06-01
Compare the result of endoscopic versus open bursectomy in lateral malleolar bursitis. Prospective evaluation of 21 patients (22 ankles) undergoing either open or endoscopic excision of lateral malleolar bursitis. The median age was 64 (38-79) years old. The median postoperative follow-up was 15 (12-18) months. Those patients undergoing endoscopic excision showed a higher satisfaction rate (excellent 9, good 2) than open excision (excellent 4, good 3, fair 1). The wounds also healed earlier in the endoscopic group although the operation time was slightly longer. One patient in the endoscopic group had recurrence of symptoms but complications in the open group included one patient with skin necrosis, one patient with wound dehiscence, and two patients of with superficial peroneal nerve injury. Endoscopic resection of the lateral malleolar bursitis is a promising technique and shows favorable results compared to the open resection. Therapeutic studies-Investigating the result of treatment, Level II.
Endoscopic Management of Tumor Bleeding from Inoperable Gastric Cancer
Kim, Young-Il
2015-01-01
Tumor bleeding is not a rare complication in patients with inoperable gastric cancer. Endoscopy has important roles in the diagnosis and primary treatment of tumor bleeding, similar to its roles in other non-variceal upper gastrointestinal bleeding cases. Although limited studies have been performed, endoscopic therapy has been highly successful in achieving initial hemostasis. One or a combination of endoscopic therapy modalities, such as injection therapy, mechanical therapy, or ablative therapy, can be used for hemostasis in patients with endoscopic stigmata of recent hemorrhage. However, rebleeding after successful hemostasis with endoscopic therapy frequently occurs. Endoscopic therapy may be a treatment option for successfully controlling this rebleeding. Transarterial embolization or palliative surgery should be considered when endoscopic therapy fails. For primary and secondary prevention of tumor bleeding, proton pump inhibitors can be prescribed, although their effectiveness to prevent bleeding remains to be investigated. PMID:25844339
Transmission of Infection by Flexible Gastrointestinal Endoscopy and Bronchoscopy
Peters, Frans T. M.; van der Mei, Henny C.; Degener, John E.
2013-01-01
SUMMARY Flexible endoscopy is a widely used diagnostic and therapeutic procedure. Contaminated endoscopes are the medical devices frequently associated with outbreaks of health care-associated infections. Accurate reprocessing of flexible endoscopes involves cleaning and high-level disinfection followed by rinsing and drying before storage. Most contemporary flexible endoscopes cannot be heat sterilized and are designed with multiple channels, which are difficult to clean and disinfect. The ability of bacteria to form biofilms on the inner channel surfaces can contribute to failure of the decontamination process. Implementation of microbiological surveillance of endoscope reprocessing is appropriate to detect early colonization and biofilm formation in the endoscope and to prevent contamination and infection in patients after endoscopic procedures. This review presents an overview of the infections and cross-contaminations related to flexible gastrointestinal endoscopy and bronchoscopy and illustrates the impact of biofilm on endoscope reprocessing and postendoscopic infection. PMID:23554415
Endoscopic methods in the treatment of early-stage esophageal cancer
2014-01-01
Most patients with early esophageal cancer restricted to the mucosa may be offered endoscopic therapy, which is similarly effective, less invasive and less expensive than esophagectomy. Selection of appropriate relevant treatment and therapy methods should be performed at a specialized center with adequate facilities. The selection of an endoscopic treatment method for high-grade dysplasia and early-stage esophageal adenocarcinoma requires that tumor infiltration is restricted to the mucosa and that there is no neighboring lymph node metastasis. In squamous cell carcinoma, this treatment method is accepted in cases of tumors invading only up to the lamina propria of mucosa (m2). Tumors treated with the endoscopic method should be well or moderately differentiated and should not invade lymphatic or blood vessels. When selecting endoscopic treatments for these lesions, a combination of endoscopic resection and endoscopic ablation methods should be considered. PMID:25097676
NASA Astrophysics Data System (ADS)
Qi, Ji; Elson, Daniel
2016-03-01
The mechanism of most medical endoscopes is based on the interaction between light and biological tissue, inclusive of absorption, elastic scattering and fluorescence. In essence, the metrics of those interactions are obtained from the fundamental properties of light as an electro-magnetic waves, namely, the radiation intensity and wavelength. As another fundamental property of light, polarisation can not only reveal tissue scattering and absorption information from a different perspective, but is also able to provide a fresh insight into directional tissue birefringence properties induced by birefringent compositions and anisotropic fibrous structures, such as collagen, elastin, muscle fibre, etc at the same time. Here we demonstrate a low cost high definition Muller polarimetric endoscope with minimal alteration of a rigid endoscope. By imaging birefringent tissue mimicking phantoms and a porcine bladder, we show that this novel endoscopic imaging modality is able to provide different information of interest from unpolarised endoscopic imaging, including linear depolarization, circular depolarization, birefringence, optic axis orientation and dichroism. This endoscope can potentially be employed for better tissue visualisation and benefit endoscopic investigations and intra-operative guidance.
Endoscopic Evacuation of Subdural Collections.
Boyaci, Suat; Gumustas, Oguzhan Guven; Korkmaz, Serdar; Aksoy, Kaya
2016-01-01
Intraoperative use of the endoscope is a hot topic in neurosurgery and it gives broader visualization of critical and hardlyreached areas. Endoscope-assisted surgical approach to chronic subdural haematoma (SDH) is a minimally invasive technique and may give an expansion to the regular method of burr-hole haematoma drainage. Endoscope-assisted haematoma drainage with mini-craniotomy was performed over a 24-month period, and prospectively collected data is reviewed. A total of 10 procedures (8 patients) were performed using the endoscopeassisted technique. Four of them were chronic SDH and six were subacute SDH. Procedures were extended 20 minutes in average because of endoscopic intervention. There was no extra-morbidity through the study as a consequence of endoscopic assessment. Endoscope-assisted techniques can make the operation safe in selected circumstances with improved intraoperative visualization. It may likewise take into consideration the identification and destruction of neo-membranes, septums and solid clots. In addition, the source of bleeding can be easily coagulated. The endoscope-assisted techniques, with all of these features, can alter the pre- and intra-operative decision-making for selected patients.
Lee, Jun; Kim, Dong-Min; Yun, Na Ra; Kim, Young Dae; Park, Chan Guk; Kim, Man Woo
2016-01-01
Scrub typhus is an infectious disease caused by Orientia tsutsugamushi-induced systemic vasculitis, but the involvement of the gastrointestinal tract and the endoscopic findings associated with scrub typhus are not well understood. We performed a prospective study and recommend performing esophagogastroduodenoscopy (EGD) for all possible scrub typhus patients, regardless of gastrointestinal symptoms. Gastrointestinal symptoms, endoscopic findings and clinical severity based on organ involvement and ICU admission were analyzed. Gastrointestinal symptoms occurred in up to 76.4% of scrub typhus patients. The major endoscopic findings were ulcers (43/127, 33.9%). Interestingly, 7.1% (9/127) of the patients presented with esophageal candidiasis. There was no correlation between the presence or absence of gastrointestinal symptoms and the endoscopic grade (P = 0.995). However, there was a positive correlation between the clinical severity and the endoscopic findings (P = 0.001). Sixty-three percent of the patients presented with erosion or ulcers on prospectively performed endoscopic evaluations, irrespective of gastrointestinal symptoms. Gastrointestinal symptoms did not reflect the need for endoscopy. Scrub typhus patients could have significant endoscopic abnormalities even in the absence of gastrointestinal symptoms.
Vignesh, Shivakumar; Hoffe, Sarah E; Meredith, Kenneth L; Shridhar, Ravi; Almhanna, Khaldoun; Gupta, Akshay K
2013-04-01
Barrett's esophagus (BE) is the most important identifiable risk factor for the progression to esophageal adenocarcinoma. This article reviews the current endoscopic therapies for BE with high-grade dysplasia and intramucosal cancer and briefly discusses the endoscopic palliation of advanced esophageal cancer. The diagnosis of low-grade or high-grade dysplasia (HGD) is based on several cytologic criteria that suggest neoplastic transformation of the columnar epithelium. HGD and carcinoma in situ are regarded as equivalent. The presence of dysplasia, particularly HGD, is also a risk factor for synchronous and metachronous adenocarcinoma. Dysplasia is a marker of adenocarcinoma and also has been shown to be the preinvasive lesion. Esophagectomy has been the conventional treatment for T1 esophageal cancer and, although debated, is an appropriate option in some patients with HGD due to the presence of occult cancer in over one-third of patients. Endoscopic ablative modalities (eg, photodynamic therapy and cryoablation) and endoscopic resection techniques (eg, endoscopic mucosal resection) have demonstrated promising results. The significant morbidity and mortality of esophagectomy makes endoscopic treatment an attractive potential option.
Tseng, Yujen; Ma, Lili; Luo, Tiancheng; Zeng, Xiaoqing; Li, Feng; Li, Na; Wei, Yichao; Chen, Shiyao
2018-04-27
Gastroesophageal variceal hemorrhage is a common complication of portal hypertension. Endoscopic therapy is currently recommended for preventing gastroesophageal variceal rebleed. However, the rate of variceal rebleed and its associated mortality remain concerning. This study is aimed at differentiating patient response to endoscopic therapy based on endoscopic ultrasound (EUS) findings. One-hundred seventy patients previously treated with repeat endoscopic therapy for secondary prophylaxis were enrolled and classified into two groups based on treatment response. Prior to consolidation therapy, all patients received an EUS examination to observe for extraluminal phenomena. All available follow-up endoscopic examination records were retrieved to validate study results. Of the 170 subjects, 106 were poor responders, while 64 were good responders. The presence of para-gastric, gastric perforating, and esophageal perforating veins was associated with poor patient response (p<0.001). The odds ratio for para-gastric veins was 5.374. Follow-up endoscopic findings for poor responders with incomplete variceal obliteration was closely correlated with the presence of para-gastric veins (p=0.002). The presence of para-gastric veins is a characteristic of poor response to endoscopic therapy for treating gastroesophageal varices. Early identification of this subgroup necessitates a change in course of treatment to improve overall patient outcome.
Ebner, F H; Roser, F; Thaher, F; Schittenhelm, J; Tatagiba, M
2010-10-01
We report about endoscope-assisted surgery of epidermoid cysts in the posterior fossa focusing on the application of neuro-endoscopy and the clinical outcome in cases of recurrent epidermoid cysts. 25 consecutively operated patients with an epidermoid cyst in the posterior fossa were retrospectively analysed. Surgeries were performed both with an operating microscope (OPMI Pentero or NC 4, Zeiss Company, Oberkochen, Germany) and endoscopic equipment (4 mm rigid endoscopes with 30° and 70° optics; Karl Storz Company, Tuttlingen, Germany) under continuous intraoperative monitoring. Surgical reports and DVD-recordings were evaluated for identification of adhesion areas and surgical details. 7 (28%) of the 25 patients were recurrences of previously operated epidermoid cysts. Mean time to recurrence was 17 years (8-22 years). In 5 cases the endoscope was used as an adjunctive tool for inspection/endoscope-assisted removal of remnants. The effective time of use of the endoscope was limited to the end stage of the procedure, but was very effective. In a modern operative setting and with the necessary surgical experience recurrent epidermoid cysts may be removed with excellent clinical results. The combined use of microscope and endoscope offers relevant advantages in demanding anatomic situations. © Georg Thieme Verlag KG Stuttgart · New York.
Endoscopic techniques in aesthetic plastic surgery.
McCain, L A; Jones, G
1995-01-01
There has been an explosive interest in endoscopic techniques by plastic surgeons over the past two years. Procedures such as facial rejuvenation, breast augmentation and abdominoplasty are being performed with endoscopic assistance. Endoscopic operations require a complex setup with components such as video camera, light sources, cables and hard instruments. The Hopkins Rod Lens system consists of optical fibers for illumination, an objective lens, an image retrieval system, a series of rods and lenses, and an eyepiece for image collection. Good illumination of the body cavity is essential for endoscopic procedures. Placement of the video camera on the eyepiece of the endoscope gives a clear, brightly illuminated large image on the monitor. The video monitor provides the surgical team with the endoscopic image. It is important to become familiar with the equipment before actually doing cases. Several options exist for staff education. In the operating room the endoscopic cart needs to be positioned to allow a clear unrestricted view of the video monitor by the surgeon and the operating team. Fogging of the endoscope may be prevented during induction by using FREDD (a fog reduction/elimination device) or a warm bath. The camera needs to be white balanced. During the procedure, the nurse monitors the level of dissection and assesses for clogging of the suction.
Predictive Factors of Atelectasis Following Endoscopic Resection.
Choe, Jung Wan; Jung, Sung Woo; Song, Jong Kyu; Shim, Euddeum; Choo, Ji Yung; Kim, Seung Young; Hyun, Jong Jin; Koo, Ja Seol; Yim, Hyung Joon; Lee, Sang Woo
2016-01-01
Atelectasis is one of the pulmonary complications associated with anesthesia. Little is known about atelectasis following endoscopic procedures under deep sedation. This study evaluated the frequency, risk factors, and clinical course of atelectasis after endoscopic resection. A total of 349 patients who underwent endoscopic resection of the upper gastrointestinal tract at a single academic tertiary referral center from March 2010 to October 2013 were enrolled. Baseline characteristics and clinical data were retrospectively reviewed from medical records. To identify atelectasis, we compared the chest radiography taken before and after the endoscopic procedure. Among the 349 patients, 68 (19.5 %) had newly developed atelectasis following endoscopic resection. In univariate logistic regression analysis, atelectasis correlated significantly with high body mass index, smoking, diabetes mellitus, procedure duration, size of lesion, and total amount of propofol. In multiple logistic regression analysis, body mass index, procedure duration, and total propofol amount were risk factors for atelectasis following endoscopic procedures. Of the 68 patients with atelectasis, nine patients developed fever, and six patients displayed pneumonic infiltration. The others had no symptoms related to atelectasis. The incidence of radiographic atelectasis following endoscopic resection was nearly 20 %. Obesity, procedural time, and amount of propofol were the significant risk factors for atelectasis following endoscopic procedure. Most cases of the atelectasis resolved spontaneously with no sequelae.
Quantitative ENT endoscopy: the future in the new millennium
NASA Astrophysics Data System (ADS)
Mueller, Andreas; Schubert, Mario
1999-06-01
In Otorhinolaryngology the endoscopic appraisal of luminal dimensions of the nose, the throat, the larynx and the trachea is a daily problem. Those concerned with endoscopy know, that endoscopes distort dimensions of examined anatomical structures. To draw conclusions on luminal dimensions from the endoscopic pictures additional measuring devices are required. We developed a new method of measuring luminal dimensions in rigid or flexible endoscopy. For this a laser beam directed radially marks the anatomical lumen of interest in the videoendoscopic vision. The laser ring becomes deformed according to the form of the cavity explored. By keeping the distance defined between the laser ring and the top of the endoscope, the endoscopic video image can be measured. A piece of software developed by us calculates from the pictures the cross sectional area as well as the extension of benign or malign stenosis of the cavity explored. The result of the endoscopic measuring procedure can be visualized 3D on a PC-monitor. We are going to demonstrate the result of our clinical experience in different otorhinolaryngological diseases with the new endoscopic measuring kit in comparison to standard endoscopy. A further perspective is the endoscopic measuring kit in comparison to standard endoscopy. A further perspective is the endoscopic assisted manufacturing (EAM) of anatomical adapted stents, tubes and cannules.
77 FR 39209 - Emerging Technology and Research Advisory Committee; Notice of Open Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2012-07-02
... DEPARTMENT OF COMMERCE Bureau of Industry and Security Emerging Technology and Research Advisory Committee; Notice of Open Meeting The Emerging Technology and Research Advisory Committee (ETRAC) will meet... Secretary for Export Administration on emerging technology and research activities, including those related...
75 FR 5952 - Emerging Technology and Research Advisory Committee; Notice of Partially Closed Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2010-02-05
... DEPARTMENT OF COMMERCE Bureau of Industry and Security Emerging Technology and Research Advisory Committee; Notice of Partially Closed Meeting The Emerging Technology and Research Advisory Committee (ETRAC... Office of the Assistant Secretary for Export Administration on emerging technology and research...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-10-12
... Noon 1. Welcome and Introductions. 2. ETRAC Member Discussion Emerging Technology Analysis. 3. Public... DEPARTMENT OF COMMERCE Bureau of Industry and Security Emerging Technology and Research Advisory Committee; Notice of Partially Closed Meeting The Emerging Technology and Research Advisory Committee (ETRAC...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-26
... Noon 1. Welcome and Introductions. 2. ETRAC Member Discussion Emerging Technology Analysis. 3. Public... DEPARTMENT OF COMMERCE Bureau of Industry and Security Emerging Technology and Research Advisory Committee; Notice of Partially Closed Meeting The Emerging Technology and Research Advisory Committee (ETRAC...
Endoscopic management of sinonasal hemangiopericytoma.
Tessema, Belachew; Eloy, Jean Anderson; Folbe, Adam J; Anstead, Amy S; Mirani, Neena M; Jourdy, Deya N; Joudy, Deya N; Ruiz, Jose W; Casiano, Roy R
2012-03-01
Sinonasal hemangiopericytomas (SNHPCs) are rare perivascular tumors with low-grade malignant potential. Traditionally, these tumors have been treated with open approaches such as lateral rhinotomy, Caldwell-Luc, or transfacial approaches. Increased experience with endoscopic management of benign and malignant sinonasal tumors has led to a shift in management of SNHPC. The authors present their experience in the largest series of patients with SNHPC managed endoscopically. Case series at a tertiary care medical center. A retrospective chart review of all patients undergoing endoscopic management of SNHPC at the University of Miami between 1999 and 2008 was conducted. All endoscopic resections were performed with curative intent. Twelve patients with the diagnosis of SNHPC were treated endoscopically. Mean age was 62.5 years (range, 51-83 years). There were 6 men and 6 women. The mean follow-up was 41 months (range, 15-91 months). Seven (58.3%) presented with nasal obstruction, whereas 4 (41.6%) had epistaxis as their initial presenting symptom. Preoperative angiography or embolization was not performed in any case. Mean estimated blood loss was 630 mL (range, 100-1500 mL). Six patients underwent endonasal endoscopic anterior skull base resection; 4 had complete endoscopic resection all with negative margins. None underwent postoperative adjuvant treatment. No recurrence or metastatic disease was observed in this patient population. Endoscopic management of SNHPC is a feasible approach and did not compromise outcomes in this experience. In this series, familiarity with advance endoscopic sinus surgery was necessary to manage these patients. Postoperative adjuvant therapy was not necessary in this cohort.
Esposito, Felice; Di Rocco, Federico; Zada, Gabriel; Cinalli, Giuseppe; Schroeder, Henry W S; Mallucci, Conor; Cavallo, Luigi M; Decq, Philippe; Chiaramonte, Carmela; Cappabianca, Paolo
2013-12-01
During the past decade, endoscopic intraventricular and skull base operations have become widely used for a variety of evolving indications. A global survey of practicing endoscopic neurosurgeons was performed to characterize patterns of usage regarding endoscopy equipment, instrumentation, and the indications for using image-guided surgery systems (IGSs). An online survey consisting of 8 questions was completed by 235 neurosurgeons with endoscopic surgical experience. Responses were entered into a database and subsequently analyzed. The median number of operations performed per year by intraventricular and skull base endoscopic surgeons was 27 and 25, respectively. Data regarding endoscopic equipment brand, diameter, and length are presented. The most commonly reported indications for IGSs during intraventricular endoscopic surgery were tumor biopsy/resection, intraventricular cyst fenestration, septostomy/pellucidotomy, endoscopic third ventriculostomy, and aqueductal stent placement. Intraventricular surgeons reported using IGSs for all cases in 16.6% and never in 24.4%. Overall, endoscopic skull base surgeons reported using IGSs for all cases in 23.9% and never in 18.9%. The most commonly reported indications for IGSs during endoscopic skull base operations were complex sinus/skull base anatomy, extended approaches, and reoperation. Many variations and permutations for performing intraventricular and skull base endoscopic surgery exist worldwide. Much can be learned by studying the patterns and indications for using various types of equipment and operative adjuncts such as IGSs. Copyright © 2013 Elsevier Inc. All rights reserved.
Kim, Su Sun; Kim, Kyung Up; Kim, Sung Jun; Seo, Seung In; Kim, Hyoung Su; Jang, Myoung Kuk; Kim, Hak Yang; Shin, Woon Geon
2017-12-15
Selecting patients with an urgent need for endoscopic hemostasis is difficult based only on simple parameters of presumed acute upper gastrointestinal bleeding. This study assessed easily applicable factors to predict cases in need of urgent endoscopic hemostasis due to acute upper gastrointestinal bleeding. The consecutively included patients were divided into the endoscopic hemostasis and nonendoscopic hemostasis groups. We reviewed the enrolled patients' medical records and analyzed various variables and parameters for acute upper gastrointestinal bleeding outcomes such as demographic factors, comorbidities, symptoms, signs, laboratory findings, rebleeding rate, and mortality to evaluate simple predictive factors for endoscopic treatment. A total of 613 patients were analyzed, including 329 patients in the endoscopic hemostasis and 284 patients in the non-endoscopic hemostasis groups. In the multivariate analysis, a bloody nasogastric lavage (adjusted odds ratio [AOR], 6.786; 95% confidence interval [CI], 3.990 to 11.543; p < 0.0001) and a hemoglobin level less than 8.6 g/dL (AOR, 1.768; 95% CI, 1.028 to 3.039; p = 0.039) were independent predictors for endoscopic hemostasis. Significant differences in the morbidity rates of endoscopic hemostasis were detected between the group with no predictive factors and the group with one or more predictive factors (OR, 2.677; 95% CI, 1.920 to 3.733; p < 0.0001). A bloody nasogastric lavage and hemoglobin < 8.6 g/dL were independent predictors of endoscopic hemostasis in patients with acute upper gastrointestinal bleeding.
Lien, Gi-Shih; Liu, Chih-Wen; Jiang, Joe-Air; Chuang, Cheng-Long; Teng, Ming-Tsung
2012-07-01
This paper presents a novel solution of a hand-held external controller to a miniaturized capsule endoscope in the gastrointestinal (GI) tract. Traditional capsule endoscopes move passively by peristaltic wave generated in the GI tract and the gravity, which makes it impossible for endoscopists to manipulate the capsule endoscope to the diagnostic disease areas. In this study, the main objective is to present an endoscopic capsule and a magnetic field navigator (MFN) that allows endoscopists to remotely control the locomotion and viewing angle of an endoscopic capsule. The attractive merits of this study are that the maneuvering of the endoscopic capsule can be achieved by the external MFN with effectiveness, low cost, and operation safety, both from a theoretical and an experimental point of view. In order to study the magnetic interactions between the endoscopic capsule and the external MFN, a magnetic-analysis model is established for computer-based finite-element simulations. In addition, experiments are conducted to show the control effectiveness of the MFN to the endoscopic capsule. Finally, several prototype endoscopic capsules and a prototype MFN are fabricated, and their actual capabilities are experimentally assessed via in vitro and ex vivo tests using a stomach model and a resected porcine stomach, respectively. Both in vitro and ex vivo test results demonstrate great potential and practicability of achieving high-precision rotation and controllable movement of the capsule using the developed MFN.
Novel endoscopic delivery modality of infrared coagulation therapy for internal hemorrhoids.
McLemore, Elisabeth C; Rai, Rudra; Siddiqui, Junaid; Basu, P Patrick; Tabbaa, Mousab; Epstein, Michael S
2012-11-01
A novel endoscopic delivery system for infrared coagulation therapy (IRC) has been designed recently. IRC is a well-established treatment for symptomatic internal hemorrhoids. Patients frequently undergo lower endoscopy before hemorrhoid treatment to eliminate other sources of bleeding. Current treatment options are difficult to perform without an anal retractor, adequate lighting, and specialized instruments. Endoscopic IRC is an attractive alternative to standard IRC, because it can be performed during the lower endoscopy. Endoscopic IRC utilizes infrared radiation generated by a control box, which is applied to the tissue through a flexible, fiber optic light guide (Precision Endoscopic Infrared Coagulator™). The light guide is placed through the colonoscope or flexible sigmoidoscope in the same chamber as other endoscopic instruments. A retrospective review was performed using a prospectively collected database. A standardized protocol was utilized in all patients. Patients graded their symptoms before and after therapy by using the visual analog symptom severity scoring system (range, 0-10). These results were analyzed by using the nonparametric Wilcoxon signed-rank test. Exact P values were computed by using the R function wilcox.exact. A total of 55 patients underwent endoscopic IRC for predominately grade II and grade III symptomatic internal hemorrhoids (71 %). There were 22 (40 %) female patients. Posttherapy results indicated a significant improvement in global symptoms (pretreatment average global score = 2.24 vs. posttreatment average global score = 0.28; P < 0.0001). There have been no adverse events reported to date. Endoscopic IRC provides improved visibility and efficiency, allowing simultaneous treatment of symptomatic internal hemorrhoids at the time of lower endoscopy. Patients experienced significant improvement in their symptoms after a single session of endoscopic IRC. There are a variety of additional endoscopic IRC therapeutic utilities: endoscopic management of angiodysplasia, inflammation, hemostasis, and NOTES applications.
Naunheim, Matthew R; Song, Phillip C; Franco, Ramon A; Alkire, Blake C; Shrime, Mark G
2017-03-01
Endoscopic management of bilateral vocal fold paralysis (BVFP) includes cordotomy and arytenoidectomy, and has become a well-accepted alternative to tracheostomy. However, the costs and quality-of-life benefits of endoscopic management have not been examined with formal economic analysis. This study undertakes a cost-effectiveness analysis of tracheostomy versus endoscopic management of BVFP. Cost-effectiveness analysis. A literature review identified a range of costs and outcomes associated with surgical options for BVFP. Additional costs were derived from Medicare reimbursement data; all were adjusted to 2014 dollars. Cost-effectiveness analysis evaluated both therapeutic strategies in short-term and long-term scenarios. Probabilistic sensitivity analysis was used to assess confidence levels regarding the economic evaluation. The incremental cost effectiveness ratio for endoscopic management versus tracheostomy is $31,600.06 per quality-adjusted life year (QALY), indicating that endoscopic management is the cost-effective short-term strategy at a willingness-to-pay (WTP) threshold of $50,000/QALY. The probability that endoscopic management is more cost-effective than tracheostomy at this WTP is 65.1%. Threshold analysis demonstrated that the model is sensitive to both utilities and cost in the short-term scenario. When costs of long-term care are included, tracheostomy is dominated by endoscopic management, indicating the cost-effectiveness of endoscopic management at any WTP. Endoscopic management of BVFP appears to be more cost-effective than tracheostomy. Though endoscopic cordotomy and arytenoidectomy require expertise and specialized equipment, this model demonstrates utility gains and long-term cost advantages to an endoscopic strategy. These findings are limited by the relative paucity of robust utility data and emphasize the need for further economic analysis in otolaryngology. NA Laryngoscope, 127:691-697, 2017. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.
Lee, T H; Moon, J H; Kim, J H; Park, D H; Lee, S S; Choi, H J; Cho, Y D; Park, S H; Kim, S J
2013-01-01
Endoscopic bilateral drainage for inoperable malignant hilar biliary strictures (HBS) using metal stents is considered to be technically difficult. Furthermore, endoscopic revision of bilateral stenting after occlusion can be challenging. This study was performed to evaluate the long-term efficacy of endoscopic bilateral stent-in-stent placement of cross-wired metallic stents in high-grade malignant HBS and planned endoscopic bilateral revision. A total of 84 patients with inoperable high-grade malignant HBS were enrolled from three academic tertiary referral centers. Two cross-wired metal stents were inserted using a bilateral stent-in-stent placement method. Bilateral endoscopic revision was also performed during follow-up using either identical metal stents or plastic stents. The main outcome measurements were technical and functional success, complications, stent patency, and endoscopic revision efficacy. The technical and clinical success rates of endoscopic bilateral stent-in-stent placement of cross-wired metallic stents were 95.2% (80/84) and 92.9% (78/84), respectively. Median patency (range) and survival were 238 days (10-429) and 256 days (10-1130), respectively. Obstruction of primary bilateral stents occurred in 30.8% (24/78) of patients with functionally successful stent placement. The technical and clinical success rates of planned bilateral endoscopic revision for occluded stents were 83.3% (20/24) and 79.2% (19/24), respectively. For revision, bilateral metallic stents were placed in 11 patients (55.0%); the remaining patients received plastic stents. Palliative endoscopic bilateral stent-in-stent placement of cross-wired metallic stents was effective in patients with inoperable HBS. Revision endoscopic bilateral stenting may be feasible and successful in cases where the primary deployed metal stents are occluded. © Georg Thieme Verlag KG Stuttgart · New York.
Shin, Hae Jin; Moon, Hee Seok; Kang, Sun Hyung; Sung, Jae Kyu; Jeong, Hyun Yong; Kim, Seok Hyun; Lee, Byung Seok; Kim, Ju Seok; Yun, Gee Young
2017-12-01
The purpose of this study was to evaluate the prognostic impact of endoscopic traversability in patients with locally advanced esophageal squamous cell carcinoma.This retrospective study was based on medical records from a single tertiary medical center. The records of 317 patients with esophageal squamous cell carcinoma treated with surgery or definitive chemoradiotherapy (CRT) between January 2009 and March 2016 were reviewed. Finally, we retrieved the data on 168 consecutive patients. These 168 patients were divided into 2 groups based on their endoscopic traversability findings: Group A (the endoscope traversable group), and Group B (the endoscope non-traversable group). We then retrospectively compared the clinical characteristics of these 2 groups.The endoscope non-traversable group (Group B) revealed an advanced clinical stage, a poor Eastern Cooperative Oncology Group (ECOG) score, a lower serum albumin level, a higher rate of requirement for esophageal stent insertion and definitive CRT as initial treatment than the endoscope traversable group (Group A). Patients with endoscope traversable cancer showed a significantly higher 3-year overall survival and 3-year relapse-free survival than patients who were endoscope non-traversable (53.8% vs 17.3%, P < .001 and 71.1% vs 45.3%, P = .003, respectively). Upon multivariate analysis of patients with locally advanced esophageal squamous cell carcinoma treated with definitive CRT, the serum albumin level <3.5 g/dL and endoscopic non-traversability were significant negative factors of survival.Endoscopic traversability in patients with locally advanced esophageal squamous cell carcinoma treated with definitive CRT is a significant prognostic factor. Copyright © 2017 The Authors. Published by Wolters Kluwer Health, Inc. All rights reserved.