Yamatsuji, Tomoki; Ishida, Naomasa; Takaoka, Munenori; Hayashi, Jiro; Yoshida, Kazuhiro; Shigemitsu, Kaori; Urakami, Atsushi; Haisa, Minoru; Naomoto, Yoshio
2017-01-01
Of 129 esophagectomies at our institute from June 2010 to March 2015, we experienced three preoperative positron emission tomography-computed tomographic (PET/CT) false positives. Bone metastasis was originally suspected in 2 cases, but they were later found to be bone metastasis negative after a preoperative bone biopsy and clinical course observation. The other cases suspected of mediastinal lymph node metastasis were diagnosed as inflammatory lymphadenopathy by a pathological examination of the removed lymph nodes. Conducting a PET/CT is useful when diagnosing esophageal cancer metastasis, but we need to be aware of the possibility of false positives. Therapeutic decisions should be made based on appropriate and accurate diagnoses, with pathological diagnosis actively introduced if necessary. PMID:28469502
Singh, Parmanand; Emami, Hamed; Subramanian, Sharath; Maurovich-Horvat, Pal; Marincheva-Savcheva, Gergana; Medina, Hector M; Abdelbaky, Amr; Alon, Achilles; Shankar, Sudha S; Rudd, James H F; Fayad, Zahi A; Hoffmann, Udo; Tawakol, Ahmed
2016-12-01
Nonobstructive coronary plaques manifesting high-risk morphology (HRM) associate with an increased risk of adverse clinical cardiovascular events. We sought to test the hypothesis that statins have a greater anti-inflammatory effect within coronary plaques containing HRM. In this prospective multicenter study, 55 subjects with or at high risk for atherosclerosis underwent 18 F-fluorodeoxyglucose positron emission tomographic/computed tomographic imaging at baseline and after 12 weeks of treatment with atorvastatin. Coronary arterial inflammation ( 18 F-fluorodeoxyglucose uptake, expressed as target-to-background ratio) was assessed in the left main coronary artery (LMCA). While blinded to the PET findings, contrast-enhanced computed tomographic angiography was performed to characterize the presence of HRM (defined as noncalcified or partially calcified plaques) in the LMCA. Arterial inflammation (target-to-background ratio) was higher in LMCA segments with HRM than those without HRM (mean±SEM: 1.95±0.43 versus 1.67±0.32 for LMCA with versus without HRM, respectively; P=0.04). Moreover, atorvastatin treatment for 12 weeks reduced target-to-background ratio more in LMCA segments with HRM than those without HRM (12 week-baseline Δtarget-to-background ratio [95% confidence interval]: -0.18 [-0.35 to -0.004] versus 0.09 [-0.06 to 0.26]; P=0.02). Furthermore, this relationship between coronary plaque morphology and change in LMCA inflammatory activity remained significant after adjusting for baseline low-density lipoprotein and statin dose (β=-0.27; P=0.038). In this first study to evaluate the impact of statins on coronary inflammation, we observed that the anti-inflammatory impact of statins is substantially greater within coronary plaques that contain HRM features. These findings suggest an additional mechanism by which statins disproportionately benefit individuals with more advanced atherosclerotic disease. URL: http://www.clinicaltrials.gov. Unique identifier: NCT00703261. © 2016 The Authors.
Data analysis in emission tomography using emission-count posteriors
NASA Astrophysics Data System (ADS)
Sitek, Arkadiusz
2012-11-01
A novel approach to the analysis of emission tomography data using the posterior probability of the number of emissions per voxel (emission count) conditioned on acquired tomographic data is explored. The posterior is derived from the prior and the Poisson likelihood of the emission-count data by marginalizing voxel activities. Based on emission-count posteriors, examples of Bayesian analysis including estimation and classification tasks in emission tomography are provided. The application of the method to computer simulations of 2D tomography is demonstrated. In particular, the minimum-mean-square-error point estimator of the emission count is demonstrated. The process of finding this estimator can be considered as a tomographic image reconstruction technique since the estimates of the number of emissions per voxel divided by voxel sensitivities and acquisition time are the estimates of the voxel activities. As an example of a classification task, a hypothesis stating that some region of interest (ROI) emitted at least or at most r-times the number of events in some other ROI is tested. The ROIs are specified by the user. The analysis described in this work provides new quantitative statistical measures that can be used in decision making in diagnostic imaging using emission tomography.
Single-photon tomographic determination of regional cerebral blood flow in epilepsy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bonte, F.J.; Devous, M.D. Sr.; Stokely, E.M.
Using a single-photon emission computed tomographic scanner (SPECT) the authors determined regional cerebral blood flow (rCBF) with inhaled xenon-133, a noninvasive procedure. Studies were performed in 40 normal individuals, and these were compared with rCBF determinations in 51 patients with seizure disorders. Although positive results were obtained in 15 of 16 patients with mass lesions, the group of principal interest comprised 25 patients suffering from ''temporal lobe'' epilepsy. Only one of these had a positive x-ray computed tomogram, but 16 had positive findings on rCBF study. These findings included increased local blood flow in the ictal state and reduced flowmore » interictally.« less
NASA Astrophysics Data System (ADS)
Yatsishina, E. B.; Kovalchuk, M. V.; Loshak, M. D.; Vasilyev, S. V.; Vasilieva, O. A.; Dyuzheva, O. P.; Pojidaev, V. M.; Ushakov, V. L.
2018-05-01
Nine ancient Egyptian mummies (dated preliminarily to the period from the 1st mill. BCE to the first centuries CE) from the collection of the State Pushkin Museum of Fine Arts have been studied at the National Research Centre "Kurchatov Institute" (NRC KI) on the base of the complex of NBICS technologies. Tomographic scanning is performed using a magneto-resonance tomograph (3 T) and a hybrid positron emission tomography/computed tomography (PET-CT) scanner. Three-dimensional reconstructions of mummies and their anthropological measurements are carried out. Some medical conclusions are drawn based on the tomographic data. In addition, the embalming composition and tissue of one of the mummies are preliminarily analyzed.
Representation of photon limited data in emission tomography using origin ensembles
NASA Astrophysics Data System (ADS)
Sitek, A.
2008-06-01
Representation and reconstruction of data obtained by emission tomography scanners are challenging due to high noise levels in the data. Typically, images obtained using tomographic measurements are represented using grids. In this work, we define images as sets of origins of events detected during tomographic measurements; we call these origin ensembles (OEs). A state in the ensemble is characterized by a vector of 3N parameters Y, where the parameters are the coordinates of origins of detected events in a three-dimensional space and N is the number of detected events. The 3N-dimensional probability density function (PDF) for that ensemble is derived, and we present an algorithm for OE image estimation from tomographic measurements. A displayable image (e.g. grid based image) is derived from the OE formulation by calculating ensemble expectations based on the PDF using the Markov chain Monte Carlo method. The approach was applied to computer-simulated 3D list-mode positron emission tomography data. The reconstruction errors for a 10 000 000 event acquisition for simulated ranged from 0.1 to 34.8%, depending on object size and sampling density. The method was also applied to experimental data and the results of the OE method were consistent with those obtained by a standard maximum-likelihood approach. The method is a new approach to representation and reconstruction of data obtained by photon-limited emission tomography measurements.
Cardiac metastases of Ewing sarcoma detected by 18F-FDG PET/CT.
Coccia, Paola; Ruggiero, Antonio; Rufini, Vittoria; Maurizi, Palma; Attinà, Giorgio; Marano, Riccardo; Natale, Luigi; Leccisotti, Lucia; Calcagni, Maria L; Riccardi, Riccardo
2012-04-01
Positron emission tomography (PET) is widely used in the diagnostic evaluation and staging of different malignant tumors. The role of PET/computed tomographic scan in detecting distant metastases in the workup of Ewing sarcoma in children or young adults is less well defined. We report a case of a boy affected by a metastatic Ewing sarcoma with cardiac asymptomatic metastasis detected by F-FDG PET/computed tomography.
Murder, insanity, and medical expert witnesses.
Ciccone, J R
1992-06-01
Recent advances in the ability to study brain anatomy and function and attempts to link these findings with human behavior have captured the attention of the legal system. This had led to the increasing use of the "neurological defense" to support a plea of not guilty by reason of insanity. This article explores the history of the insanity defense and explores the role of the medical expert witnesses in integrating clinical and laboratory findings, eg, computed tomographic scans, magnetic resonance scans, and single-photon emission computed tomographic scans. Three cases involving murder and brain dysfunction are discussed: the first case involves a subarachnoid hemorrhage resulting in visual perceptual and memory impairment; the second case, a diagnosis of Alzheimer's disease; and the third case, the controverted diagnosis of complex partial seizures in a serial killer.
Schmidt, Sergio L; Schmidt, Juliana J; Tolentino, Julio C; Ferreira, Carlos G; de Almeida, Sergio A; Alvarenga, Regina P; Simoes, Eunice N; Schmidt, Guilherme J; Canedo, Nathalie H S; Chimelli, Leila
2016-07-20
Limbic encephalitis was originally described as a rare clinical neuropathological entity involving seizures and neuropsychological disturbances. In this report, we describe cerebral patterns visualized by positron emission tomography in a patient with limbic encephalitis and cholangiocarcinoma. To our knowledge, there is no other description in the literature of cerebral positron emission tomography findings in the setting of limbic encephalitis and subsequent diagnosis of cholangiocarcinoma. We describe a case of a 77-year-old Caucasian man who exhibited persistent cognitive changes 2 years before his death. A cerebral scan obtained at that time by 2-deoxy-2-[fluorine-18]fluoro- D -glucose integrated with computed tomography-positron emission tomography showed low radiotracer uptake in the frontal and temporal lobes. Cerebrospinal fluid analysis indicated the presence of voltage-gated potassium channel antibodies. Three months before the patient's death, a lymph node biopsy indicated a cholangiocarcinoma, and a new cerebral scan obtained by 2-deoxy-2-[fluorine-18]fluoro-D-glucose integrated with computed tomography-positron emission tomography showed an increment in the severity of metabolic deficit in the frontal and parietal lobes, as well as hypometabolism involving the temporal lobes. Two months before the patient's death, cerebral metastases were detected on a contrast-enhanced computed tomographic scan. Postmortem examination revealed a cholangiocarcinoma with multiple metastases including the lungs and lymph nodes. The patient's brain weighed 1300 g, and mild cortical atrophy, ex vacuo dilation of the ventricles, and mild focal thickening of the cerebellar leptomeninges, which were infiltrated by neoplastic epithelial cells, were observed. These findings support the need for continued vigilance in malignancy surveillance in patients with limbic encephalitis and early cerebral positron emission tomographic scan abnormalities. The difficulty in early diagnosis of small tumors, such as a cholangiocarcinoma, is discussed in the context of the clinical utility of early cerebral hypometabolism detected by 2-deoxy-2-[fluorine-18]fluoro-D-glucose integrated with computed tomography-positron emission tomography in patients with rapidly progressive dementia.
Tomographic capabilities of the new GEM based SXR diagnostic of WEST
NASA Astrophysics Data System (ADS)
Jardin, A.; Mazon, D.; O'Mullane, M.; Mlynar, J.; Loffelmann, V.; Imrisek, M.; Chernyshova, M.; Czarski, T.; Kasprowicz, G.; Wojenski, A.; Bourdelle, C.; Malard, P.
2016-07-01
The tokamak WEST (Tungsten Environment in Steady-State Tokamak) will start operating by the end of 2016 as a test bed for the ITER divertor components in long pulse operation. In this context, radiative cooling of heavy impurities like tungsten (W) in the Soft X-ray (SXR) range [0.1 keV; 20 keV] is a critical issue for the plasma core performances. Thus reliable tools are required to monitor the local impurity density and avoid W accumulation. The WEST SXR diagnostic will be equipped with two new GEM (Gas Electron Multiplier) based poloidal cameras allowing to perform 2D tomographic reconstructions in tunable energy bands. In this paper tomographic capabilities of the Minimum Fisher Information (MFI) algorithm developed for Tore Supra and upgraded for WEST are investigated, in particular through a set of emissivity phantoms and the standard WEST scenario including reconstruction errors, influence of noise as well as computational time.
Normal-pressure hydrocephalus and the saga of the treatable dementias
DOE Office of Scientific and Technical Information (OSTI.GOV)
Friedland, R.P.
1989-11-10
A case study of a 74-year-old woman is presented which illustrates the difficulty of understanding dementing illnesses. A diagnosis of normal-pressure hydrocephalus (NPH) was made because of the development of abnormal gait, with urinary incontinence and severe, diffuse, white matter lesions on the MRI scan. Computed tomographic, MRI scans and positron emission tomographic images of glucose use are presented. The treatable dementias are a large, multifaceted group of illnesses, of which NPH is one. The author proposes a new term for this disorder commonly known as NPH because the problem with the term normal-pressure hydrocephalus is that the cerebrospinal fluidmore » pressure is not always normal in the disease.« less
Regional brain hematocrit in stroke by single photon emission computed tomography imaging
DOE Office of Scientific and Technical Information (OSTI.GOV)
Loutfi, I.; Frackowiak, R.S.; Myers, M.J.
1987-01-01
Nineteen studies on 18 subjects were performed by single photon emission computed tomography (SPECT) of the head after the successive intravenous administration of a plasma label (/sup 99m/Tc-human serum albumin (HSA)) and /sup 99m/Tc-labeled autologous red blood cells (RBC). Two sets of cerebral tomographic sections were generated: for cerebral /sup 99m/Tc-HSA alone and for combined /sup 99m/Tc-HSA and /sup 99m/Tc-RBC. By relating counts in regions of interest from the cerebral tomograms to counts from blood samples obtained during each tomographic acquisition, regional cerebral haematocrit (Hct) was calculated by the application of a simple formula. Results show 1) lower cerebral Hctmore » than venous Hct (ratio of HCT brain/Hct venous 0.65-0.90) in all subjects, and 2) comparison between right and left hemisphere Hct in 3/3 normal subjects, 6/6 patients with transient ischaemic attacks and 3/8 patients with stroke showed no significant difference. However, in 3/8 patients with stroke (most recent strokes) significant differences were found, the higher Hct value corresponding to the affected side.« less
Imaging of turbulent structures and tomographic reconstruction of TORPEX plasma emissivity
NASA Astrophysics Data System (ADS)
Iraji, D.; Furno, I.; Fasoli, A.; Theiler, C.
2010-12-01
In the TORPEX [A. Fasoli et al., Phys. Plasmas 13, 055902 (2006)], a simple magnetized plasma device, low frequency electrostatic fluctuations associated with interchange waves, are routinely measured by means of extensive sets of Langmuir probes. To complement the electrostatic probe measurements of plasma turbulence and study of plasma structures smaller than the spatial resolution of probes array, a nonperturbative direct imaging system has been developed on TORPEX, including a fast framing Photron-APX-RS camera and an image intensifier unit. From the line-integrated camera images, we compute the poloidal emissivity profile of the plasma by applying a tomographic reconstruction technique using a pixel method and solving an overdetermined set of equations by singular value decomposition. This allows comparing statistical, spectral, and spatial properties of visible light radiation with electrostatic fluctuations. The shape and position of the time-averaged reconstructed plasma emissivity are observed to be similar to those of the ion saturation current profile. In the core plasma, excluding the electron cyclotron and upper hybrid resonant layers, the mean value of the plasma emissivity is observed to vary with (Te)α(ne)β, in which α =0.25-0.7 and β =0.8-1.4, in agreement with collisional radiative model. The tomographic reconstruction is applied to the fast camera movie acquired with 50 kframes/s rate and 2 μs of exposure time to obtain the temporal evolutions of the emissivity fluctuations. Conditional average sampling is also applied to visualize and measure sizes of structures associated with the interchange mode. The ω-time and the two-dimensional k-space Fourier analysis of the reconstructed emissivity fluctuations show the same interchange mode that is detected in the ω and k spectra of the ion saturation current fluctuations measured by probes. Small scale turbulent plasma structures can be detected and tracked in the reconstructed emissivity movies with the spatial resolution down to 2 cm, well beyond the spatial resolution of the probe array.
Offodile, Anaeze C; Chatterjee, Abhishek; Vallejo, Sergio; Fisher, Carla S; Tchou, Julia C; Guo, Lifei
2015-04-01
Computed tomographic angiography is a diagnostic tool increasingly used for preoperative vascular mapping in abdomen-based perforator flap breast reconstruction. This study compared the use of computed tomographic angiography and the conventional practice of Doppler ultrasonography only in postmastectomy reconstruction using a cost-utility model. Following a comprehensive literature review, a decision analytic model was created using the three most clinically relevant health outcomes in free autologous breast reconstruction with computed tomographic angiography versus Doppler ultrasonography only. Cost and utility estimates for each health outcome were used to derive the quality-adjusted life-years and incremental cost-utility ratio. One-way sensitivity analysis was performed to scrutinize the robustness of the authors' results. Six studies and 782 patients were identified. Cost-utility analysis revealed a baseline cost savings of $3179, a gain in quality-adjusted life-years of 0.25. This yielded an incremental cost-utility ratio of -$12,716, implying a dominant choice favoring preoperative computed tomographic angiography. Sensitivity analysis revealed that computed tomographic angiography was costlier when the operative time difference between the two techniques was less than 21.3 minutes. However, the clinical advantage of computed tomographic angiography over Doppler ultrasonography only showed that computed tomographic angiography would still remain the cost-effective option even if it offered no additional operating time advantage. The authors' results show that computed tomographic angiography is a cost-effective technology for identifying lower abdominal perforators for autologous breast reconstruction. Although the perfect study would be a randomized controlled trial of the two approaches with true cost accrual, the authors' results represent the best available evidence.
Counts, Sarah J; Kim, Anthony W
2017-08-01
Modalities to detect and characterize lung cancer are generally divided into those that are invasive [endobronchial ultrasound (EBUS), esophageal ultrasound (EUS), and electromagnetic navigational bronchoscopy (ENMB)] versus noninvasive [chest radiography (CXR), computed tomography (CT), positron emission tomography (PET), and magnetic resonance imaging (MRI)]. This chapter describes these modalities, the literature supporting their use, and delineates what tests to use to best evaluate the patient with lung cancer. Copyright © 2017 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Choong, W. -S.; Abu-Nimeh, F.; Moses, W. W.
Here, we present a 16-channel front-end readout board for the OpenPET electronics system. A major task in developing a nuclear medical imaging system, such as a positron emission computed tomograph (PET) or a single-photon emission computed tomograph (SPECT), is the electronics system. While there are a wide variety of detector and camera design concepts, the relatively simple nature of the acquired data allows for a common set of electronics requirements that can be met by a flexible, scalable, and high-performance OpenPET electronics system. The analog signals from the different types of detectors used in medical imaging share similar characteristics, whichmore » allows for a common analog signal processing. The OpenPET electronics processes the analog signals with Detector Boards. Here we report on the development of a 16-channel Detector Board. Each signal is digitized by a continuously sampled analog-to-digital converter (ADC), which is processed by a field programmable gate array (FPGA) to extract pulse height information. A leading edge discriminator creates a timing edge that is "time stamped" by a time-to-digital converter (TDC) implemented inside the FPGA. In conclusion, this digital information from each channel is sent to an FPGA that services 16 analog channels, and then information from multiple channels is processed by this FPGA to perform logic for crystal lookup, DOI calculation, calibration, etc.« less
Vanderperren, K; Bergman, H J; Spoormakers, T J P; Pille, F; Duchateau, L; Puchalski, S M; Saunders, J H
2014-07-01
Lysis of the axial aspect of equine proximal sesamoid bones (PSBs) is a rare condition reported to have septic or traumatic origins. Limited information exists regarding imaging of nonseptic axial osteitis of a PSB. To report the clinical, radiographic, ultrasonographic, computed tomographic and intra-arterial contrast-enhanced computed tomographic abnormalities in horses with axial nonseptic osteitis of a PSB. Retrospective clinical study. Eighteen horses diagnosed with nonseptic osteitis of the axial border of a PSB between 2007 and 2012 were reviewed retrospectively. Case details, clinical examination, radiographic, ultrasonographic, computed tomographic and intra-arterial/intra-articular contrast-enhanced computed tomographic features were recorded, when available. Radiographic, ultrasonographic and computed tomographic evaluations of the fetlock region had been performed on 18, 15 and 9 horses, respectively. The effect of the degree of lysis on the grade and duration of lameness was determined. All horses had chronic unilateral lameness, 4 with forelimb and 14 with hindlimb signs. On radiographs, lysis was identified in both PSBs in 14 horses, one PSB in 3 horses and in one horse no lysis was identified. The degree of osteolysis was variable. Ultrasonography identified variably sized irregularities of the bone surface and alteration in echogenicity of the palmar/plantar ligament (PL). All horses undergoing computed tomographic examination (n = 9) had biaxial lysis. The lesions were significantly longer and deeper on computed tomographic images compared with radiographic images. Intra-arterial contrast-enhanced computed tomography may reveal moderate to marked contrast enhancement of the PL. There was no significant effect of the degree of lysis on the grade and duration of lameness. Lesions of nonseptic axial osteitis of a PSB can be identified using a combination of radiography and ultrasonography. Computed tomography provides additional information regarding the extent of the pathology. © 2013 EVJ Ltd.
Rose, Michael; Rubal, Bernard; Hulten, Edward; Slim, Jennifer N; Steel, Kevin; Furgerson, James L; Villines, Todd C
2014-01-01
Background: The correlation between normal cardiac chamber linear dimensions measured during retrospective coronary computed tomographic angiography as compared to transthoracic echocardiography using the American Society of Echocardiography guidelines is not well established. Methods: We performed a review from January 2005 to July 2011 to identify subjects with retrospective electrocardiogram-gated coronary computed tomographic angiography scans for chest pain and transthoracic echocardiography with normal cardiac structures performed within 90 days. Dimensions were manually calculated in both imaging modalities in accordance with the American Society of Echocardiography published guidelines. Left ventricular ejection fraction was calculated on echocardiography manually using the Simpson’s formula and by coronary computed tomographic angiography using the end-systolic and end-diastolic volumes. Results: We reviewed 532 studies, rejected 412 and had 120 cases for review with a median time between studies of 7 days (interquartile range (IQR25,75) = 0–22 days) with no correlation between the measurements made by coronary computed tomographic angiography and transthoracic echocardiography using Bland–Altman analysis. We generated coronary computed tomographic angiography cardiac dimension reference ranges for both genders for our population. Conclusion: Our findings represent a step towards generating cardiac chamber dimensions’ reference ranges for coronary computed tomographic angiography as compared to transthoracic echocardiography in patients with normal cardiac morphology and function using the American Society of Echocardiography guideline measurements that are commonly used by cardiologists. PMID:26770706
Imaging of turbulent structures and tomographic reconstruction of TORPEX plasma emissivity
DOE Office of Scientific and Technical Information (OSTI.GOV)
Iraji, D.; Furno, I.; Fasoli, A.
In the TORPEX [A. Fasoli et al., Phys. Plasmas 13, 055902 (2006)], a simple magnetized plasma device, low frequency electrostatic fluctuations associated with interchange waves, are routinely measured by means of extensive sets of Langmuir probes. To complement the electrostatic probe measurements of plasma turbulence and study of plasma structures smaller than the spatial resolution of probes array, a nonperturbative direct imaging system has been developed on TORPEX, including a fast framing Photron-APX-RS camera and an image intensifier unit. From the line-integrated camera images, we compute the poloidal emissivity profile of the plasma by applying a tomographic reconstruction technique usingmore » a pixel method and solving an overdetermined set of equations by singular value decomposition. This allows comparing statistical, spectral, and spatial properties of visible light radiation with electrostatic fluctuations. The shape and position of the time-averaged reconstructed plasma emissivity are observed to be similar to those of the ion saturation current profile. In the core plasma, excluding the electron cyclotron and upper hybrid resonant layers, the mean value of the plasma emissivity is observed to vary with (T{sub e}){sup {alpha}}(n{sub e}){sup {beta}}, in which {alpha}=0.25-0.7 and {beta}=0.8-1.4, in agreement with collisional radiative model. The tomographic reconstruction is applied to the fast camera movie acquired with 50 kframes/s rate and 2 {mu}s of exposure time to obtain the temporal evolutions of the emissivity fluctuations. Conditional average sampling is also applied to visualize and measure sizes of structures associated with the interchange mode. The {omega}-time and the two-dimensional k-space Fourier analysis of the reconstructed emissivity fluctuations show the same interchange mode that is detected in the {omega} and k spectra of the ion saturation current fluctuations measured by probes. Small scale turbulent plasma structures can be detected and tracked in the reconstructed emissivity movies with the spatial resolution down to 2 cm, well beyond the spatial resolution of the probe array.« less
Business aspects of cardiovascular computed tomography: tackling the challenges.
Bateman, Timothy M
2008-01-01
The purpose of this article is to provide a comprehensive understanding of the business issues surrounding provision of dedicated cardiovascular computed tomographic imaging. Some of the challenges include high up-front costs, current low utilization relative to scanner capability, and inadequate payments. Cardiovascular computed tomographic imaging is a valuable clinical modality that should be offered by cardiovascular centers-of-excellence. With careful consideration of the business aspects, moderate-to-large size cardiology programs should be able to implement an economically viable cardiovascular computed tomographic service.
SSULI/SSUSI UV Tomographic Images of Large-Scale Plasma Structuring
NASA Astrophysics Data System (ADS)
Hei, M. A.; Budzien, S. A.; Dymond, K.; Paxton, L. J.; Schaefer, R. K.; Groves, K. M.
2015-12-01
We present a new technique that creates tomographic reconstructions of atmospheric ultraviolet emission based on data from the Special Sensor Ultraviolet Limb Imager (SSULI) and the Special Sensor Ultraviolet Spectrographic Imager (SSUSI), both flown on the Defense Meteorological Satellite Program (DMSP) Block 5D3 series satellites. Until now, the data from these two instruments have been used independently of each other. The new algorithm combines SSULI/SSUSI measurements of 135.6 nm emission using the tomographic technique; the resultant data product - whole-orbit reconstructions of atmospheric volume emission within the satellite orbital plane - is substantially improved over the original data sets. Tests using simulated atmospheric emission verify that the algorithm performs well in a variety of situations, including daytime, nighttime, and even in the challenging terminator regions. A comparison with ALTAIR radar data validates that the volume emission reconstructions can be inverted to yield maps of electron density. The algorithm incorporates several innovative new features, including the use of both SSULI and SSUSI data to create tomographic reconstructions, the use of an inversion algorithm (Richardson-Lucy; RL) that explicitly accounts for the Poisson statistics inherent in optical measurements, and a pseudo-diffusion based regularization scheme implemented between iterations of the RL code. The algorithm also explicitly accounts for extinction due to absorption by molecular oxygen.
Koukourakis, G; Maravelis, G; Koukouraki, S; Padelakos, P; Kouloulias, V
2009-01-01
The concept of emission and transmission tomography was introduced by David Kuhl and Roy Edwards in the late 1950s. Their work later led to the design and construction of several tomographic instruments at the University of Pennsylvania. Tomographic imaging techniques were further developed by Michel Ter-Pogossian, Michael E. Phelps and others at the Washington University School of Medicine. Positron emission tomography (PET) is a nuclear medicine imaging technique which produces a 3-dimensional image or map of functional processes in the body. The system detects pairs of gamma rays emitted indirectly by a positron-emitting radionuclide (tracer), which is introduced into the body on a biologically active molecule. Images of tracer concentration in 3-dimensional space within the body are then reconstructed by computer analysis. In modern scanners, this reconstruction is often accomplished with the aid of a CT X-ray scan performed on the patient during the same session, in the same machine. If the biologically active molecule chosen for PET is 18F-fluorodeoxyglucose (FDG), an analogue of glucose, the concentrations of tracer imaged give tissue metabolic activity in terms of regional glucose uptake. Although use of this tracer results in the most common type of PET scan, other tracer molecules are used in PET to image the tissue concentration of many other types of molecules of interest. The main role of this article was to analyse the available types of radiopharmaceuticals used in PET-CT along with the principles of its clinical and technical considerations.
NASA Astrophysics Data System (ADS)
Olaguer, Eduardo P.; Stutz, Jochen; Erickson, Matthew H.; Hurlock, Stephen C.; Cheung, Ross; Tsai, Catalina; Colosimo, Santo F.; Festa, James; Wijesinghe, Asanga; Neish, Bradley S.
2017-02-01
During the Benzene and other Toxics Exposure (BEE-TEX) study, a remote sensing network based on long path Differential Optical Absorption Spectroscopy (DOAS) was set up in the Manchester neighborhood beside the Ship Channel of Houston, Texas in order to perform Computer Aided Tomography (CAT) scans of hazardous air pollutants. On 18-19 February 2015, the CAT scan network detected large nocturnal plumes of toluene and xylenes most likely associated with railcar loading and unloading operations at Ship Channel petrochemical facilities. The presence of such plumes during railcar operations was confirmed by a mobile laboratory equipped with a Proton Transfer Reaction-Mass Spectrometer (PTR-MS), which measured transient peaks of toluene and C2-benzenes of 50 ppb and 57 ppb respectively around 4 a.m. LST on 19 February 2015. Plume reconstruction and source attribution were performed using the 4D variational data assimilation technique and a 3D micro-scale forward and adjoint air quality model based on both tomographic and PTR-MS data. Inverse model estimates of fugitive emissions associated with railcar transfer emissions ranged from 2.0 to 8.2 kg/hr for toluene and from 2.2 to 3.5 kg/hr for xylenes in the early morning of 19 February 2015.
A front-end readout Detector Board for the OpenPET electronics system
NASA Astrophysics Data System (ADS)
Choong, W.-S.; Abu-Nimeh, F.; Moses, W. W.; Peng, Q.; Vu, C. Q.; Wu, J.-Y.
2015-08-01
We present a 16-channel front-end readout board for the OpenPET electronics system. A major task in developing a nuclear medical imaging system, such as a positron emission computed tomograph (PET) or a single-photon emission computed tomograph (SPECT), is the electronics system. While there are a wide variety of detector and camera design concepts, the relatively simple nature of the acquired data allows for a common set of electronics requirements that can be met by a flexible, scalable, and high-performance OpenPET electronics system. The analog signals from the different types of detectors used in medical imaging share similar characteristics, which allows for a common analog signal processing. The OpenPET electronics processes the analog signals with Detector Boards. Here we report on the development of a 16-channel Detector Board. Each signal is digitized by a continuously sampled analog-to-digital converter (ADC), which is processed by a field programmable gate array (FPGA) to extract pulse height information. A leading edge discriminator creates a timing edge that is ``time stamped'' by a time-to-digital converter (TDC) implemented inside the FPGA . This digital information from each channel is sent to an FPGA that services 16 analog channels, and then information from multiple channels is processed by this FPGA to perform logic for crystal lookup, DOI calculation, calibration, etc.
A front-end readout Detector Board for the OpenPET electronics system
Choong, W. -S.; Abu-Nimeh, F.; Moses, W. W.; ...
2015-08-12
Here, we present a 16-channel front-end readout board for the OpenPET electronics system. A major task in developing a nuclear medical imaging system, such as a positron emission computed tomograph (PET) or a single-photon emission computed tomograph (SPECT), is the electronics system. While there are a wide variety of detector and camera design concepts, the relatively simple nature of the acquired data allows for a common set of electronics requirements that can be met by a flexible, scalable, and high-performance OpenPET electronics system. The analog signals from the different types of detectors used in medical imaging share similar characteristics, whichmore » allows for a common analog signal processing. The OpenPET electronics processes the analog signals with Detector Boards. Here we report on the development of a 16-channel Detector Board. Each signal is digitized by a continuously sampled analog-to-digital converter (ADC), which is processed by a field programmable gate array (FPGA) to extract pulse height information. A leading edge discriminator creates a timing edge that is "time stamped" by a time-to-digital converter (TDC) implemented inside the FPGA. In conclusion, this digital information from each channel is sent to an FPGA that services 16 analog channels, and then information from multiple channels is processed by this FPGA to perform logic for crystal lookup, DOI calculation, calibration, etc.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ceglio, N.M.; George, E.V.; Brooks, K.M.
The first successful demonstration of high resolution, tomographic imaging of a laboratory plasma using coded imaging techniques is reported. ZPCI has been used to image the x-ray emission from laser compressed DT filled microballoons. The zone plate camera viewed an x-ray spectral window extending from below 2 keV to above 6 keV. It exhibited a resolution approximately 8 ..mu..m, a magnification factor approximately 13, and subtended a radiation collection solid angle at the target approximately 10/sup -2/ sr. X-ray images using ZPCI were compared with those taken using a grazing incidence reflection x-ray microscope. The agreement was excellent. In addition,more » the zone plate camera produced tomographic images. The nominal tomographic resolution was approximately 75 ..mu..m. This allowed three dimensional viewing of target emission from a single shot in planar ''slices''. In addition to its tomographic capability, the great advantage of the coded imaging technique lies in its applicability to hard (greater than 10 keV) x-ray and charged particle imaging. Experiments involving coded imaging of the suprathermal x-ray and high energy alpha particle emission from laser compressed microballoon targets are discussed.« less
Tomographic inversion of satellite photometry. II
NASA Technical Reports Server (NTRS)
Solomon, S. C.; Hays, P. B.; Abreu, V. J.
1985-01-01
A method for combining nadir observations of emission features in the upper atmosphere with the result of a tomographic inversion of limb brightness measurements is presented. Simulated and actual results are provided, and error sensitivity is investigated.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nakajima, K.; Bunko, H.; Tada, A.
1984-01-01
Phase analysis has been applied to Wolff-Parkinson-White syndrome (WPW) to detect the site of accessory conduction pathway (ACP); however, there was a limitation to estimate the precise location of ACP by planar phase analysis. In this study, the authors applied phase analysis to gated blood pool tomography. Twelve patients with WPW who underwent epicardial mapping and surgical division of ACP were studied by both of gated emission computed tomography (GECT) and routine gated blood pool study (GBPS). The GBPS was performed with Tc-99m red blood cells in multiple projections; modified left anterior oblique, right anterior oblique and/or left lateral views.more » In GECT, short axial, horizontal and vertical long axial blood pool images were reconstructed. Phase analysis was performed using fundamental frequency of the Fourier transform in both GECT and GBPS images, and abnormal initial contractions on both the planar and tomographic phase analysis were compared with the location of surgically confirmed ACPs. In planar phase analysis, abnormal initial phase was identified in 7 out of 12 (58%) patients, while in tomographic phase analysis, the localization of ACP was predicted in 11 out of 12 (92%) patients. Tomographic phase analysis is superior to planar phase images in 8 out of 12 patients to estimate the location of ACP. Phase analysis by GECT can avoid overlap of blood pool in cardiac chambers and has advantage to identify the propagation of phase three-dimensionally. Tomographic phase analysis is a good adjunctive method for patients with WPW to estimate the site of ACP.« less
DOE R&D Accomplishments Database
Phelps, M. E.; Hoffman, E. J.; Huang, S. C.; Schelbert, H. R.; Kuhl, D. E.
1978-01-01
Emission computed tomography can provide a quantitative in vivo measurement of regional tissue radionuclide tracer concentrations. This facility when combined with physiologic models and radioactively labeled physiologic tracers that behave in a predictable manner allow measurement of a wide variety of physiologic variables. This integrated technique has been referred to as Physiologic Tomography (PT). PT requires labeled compounds which trace physiologic processes in a known and predictable manner, and physiologic models which are appropriately formulated and validated to derive physiologic variables from ECT data. In order to effectively achieve this goal, PT requires an ECT system that is capable of performing truly quantitative or analytical measurements of tissue tracer concentrations and which has been well characterized in terms of spatial resolution, sensitivity and signal to noise ratios in the tomographic image. This paper illustrates the capabilities of emission computed tomography and provides examples of physiologic tomography for the regional measurement of cerebral and myocardial metabolic rate for glucose, regional measurement of cerebral blood volume, gated cardiac blood pools and capillary perfusion in brain and heart. Studies on patients with stroke and myocardial ischemia are also presented.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pablant, N. A.; Bell, R. E.; Bitter, M.
2014-11-15
Accurate tomographic inversion is important for diagnostic systems on stellarators and tokamaks which rely on measurements of line integrated emission spectra. A tomographic inversion technique based on spline optimization with enforcement of constraints is described that can produce unique and physically relevant inversions even in situations with noisy or incomplete input data. This inversion technique is routinely used in the analysis of data from the x-ray imaging crystal spectrometer (XICS) installed at the Large Helical Device. The XICS diagnostic records a 1D image of line integrated emission spectra from impurities in the plasma. Through the use of Doppler spectroscopy andmore » tomographic inversion, XICS can provide profile measurements of the local emissivity, temperature, and plasma flow. Tomographic inversion requires the assumption that these measured quantities are flux surface functions, and that a known plasma equilibrium reconstruction is available. In the case of low signal levels or partial spatial coverage of the plasma cross-section, standard inversion techniques utilizing matrix inversion and linear-regularization often cannot produce unique and physically relevant solutions. The addition of physical constraints, such as parameter ranges, derivative directions, and boundary conditions, allow for unique solutions to be reliably found. The constrained inversion technique described here utilizes a modified Levenberg-Marquardt optimization scheme, which introduces a condition avoidance mechanism by selective reduction of search directions. The constrained inversion technique also allows for the addition of more complicated parameter dependencies, for example, geometrical dependence of the emissivity due to asymmetries in the plasma density arising from fast rotation. The accuracy of this constrained inversion technique is discussed, with an emphasis on its applicability to systems with limited plasma coverage.« less
Pablant, N. A.; Bell, R. E.; Bitter, M.; ...
2014-08-08
Accurate tomographic inversion is important for diagnostic systems on stellarators and tokamaks which rely on measurements of line integrated emission spectra. A tomographic inversion technique based on spline optimization with enforcement of constraints is described that can produce unique and physically relevant inversions even in situations with noisy or incomplete input data. This inversion technique is routinely used in the analysis of data from the x-ray imaging crystal spectrometer (XICS) installed at LHD. The XICS diagnostic records a 1D image of line integrated emission spectra from impurities in the plasma. Through the use of Doppler spectroscopy and tomographic inversion, XICSmore » can provide pro file measurements of the local emissivity, temperature and plasma flow. Tomographic inversion requires the assumption that these measured quantities are flux surface functions, and that a known plasma equilibrium reconstruction is available. In the case of low signal levels or partial spatial coverage of the plasma cross-section, standard inversion techniques utilizing matrix inversion and linear-regularization often cannot produce unique and physically relevant solutions. The addition of physical constraints, such as parameter ranges, derivative directions, and boundary conditions, allow for unique solutions to be reliably found. The constrained inversion technique described here utilizes a modifi ed Levenberg-Marquardt optimization scheme, which introduces a condition avoidance mechanism by selective reduction of search directions. The constrained inversion technique also allows for the addition of more complicated parameter dependencies, for example geometrical dependence of the emissivity due to asymmetries in the plasma density arising from fast rotation. The accuracy of this constrained inversion technique is discussed, with an emphasis on its applicability to systems with limited plasma coverage.« less
Tomographic Image Compression Using Multidimensional Transforms.
ERIC Educational Resources Information Center
Villasenor, John D.
1994-01-01
Describes a method for compressing tomographic images obtained using Positron Emission Tomography (PET) and Magnetic Resonance (MR) by applying transform compression using all available dimensions. This takes maximum advantage of redundancy of the data, allowing significant increases in compression efficiency and performance. (13 references) (KRN)
NASA Technical Reports Server (NTRS)
Mcdade, Ian C.
1991-01-01
Techniques were developed for recovering two-dimensional distributions of auroral volume emission rates from rocket photometer measurements made in a tomographic spin scan mode. These tomographic inversion procedures are based upon an algebraic reconstruction technique (ART) and utilize two different iterative relaxation techniques for solving the problems associated with noise in the observational data. One of the inversion algorithms is based upon a least squares method and the other on a maximum probability approach. The performance of the inversion algorithms, and the limitations of the rocket tomography technique, were critically assessed using various factors such as (1) statistical and non-statistical noise in the observational data, (2) rocket penetration of the auroral form, (3) background sources of emission, (4) smearing due to the photometer field of view, and (5) temporal variations in the auroral form. These tests show that the inversion procedures may be successfully applied to rocket observations made in medium intensity aurora with standard rocket photometer instruments. The inversion procedures have been used to recover two-dimensional distributions of auroral emission rates and ionization rates from an existing set of N2+3914A rocket photometer measurements which were made in a tomographic spin scan mode during the ARIES auroral campaign. The two-dimensional distributions of the 3914A volume emission rates recoverd from the inversion of the rocket data compare very well with the distributions that were inferred from ground-based measurements using triangulation-tomography techniques and the N2 ionization rates derived from the rocket tomography results are in very good agreement with the in situ particle measurements that were made during the flight. Three pre-prints describing the tomographic inversion techniques and the tomographic analysis of the ARIES rocket data are included as appendices.
NASA Astrophysics Data System (ADS)
Santos-Costa, D.; Bolton, S. J.; Adumitroaie, V.; Janssen, M.; Levin, S.; Sault, R. J.; De Pater, I.; Tao, C.
2015-12-01
The Juno spacecraft will go into polar orbit after it arrives at Jupiter in mid-2016. Between November 2016 and March 2017, six MicroWave Radiometers will collect information on Jupiter's atmosphere and electron belt. Here we present simulations of MWR observations of the electron belt synchrotron emission, and discuss the features and dynamical behavior of this emission when observations are carried out from inside the radiation zone. We first present our computation method. We combine a three-dimensional tomographic reconstruction method of Earth-based observations and a theoretical model of Jupiter's electron belt to constrain the calculations of the volume emissivity of the synchrotron radiation for any frequency, location in the Jovian inner magnetosphere (radial distance < 4 Rj), and observational direction. Values of the computed emissivity are incorporated into a synchrotron simulator to predict Juno MWR measurements (full sky maps and temperatures) at any time of the mission. Samples of simulated MWR observations are presented and examined for different segments of Juno trajectory. We also present results of our ongoing investigation of the radiation zone distribution around the planet and the sources of variation on different time-scales. We show that a better understanding of the spatial distribution and variability of the electron belt is key to realistically forecast Juno MWR measurements.
Sporns, Peter B; Schwake, Michael; Schmidt, Rene; Kemmling, André; Minnerup, Jens; Schwindt, Wolfram; Cnyrim, Christian; Zoubi, Tarek; Heindel, Walter; Niederstadt, Thomas; Hanning, Uta
2017-01-01
Significant early hematoma growth in patients with intracerebral hemorrhage is an independent predictor of poor functional outcome. Recently, the novel blend sign (BS) has been introduced as a new imaging sign for predicting hematoma growth in noncontrast computed tomography. Another parameter predicting increasing hematoma size is the well-established spot sign (SS) visible in computed tomographic angiography. We, therefore, aimed to clarify the association between established SS and novel BS and their values predicting a secondary neurological deterioration. Retrospective study inclusion criteria were (1) spontaneous intracerebral hemorrhage confirmed on noncontrast computed tomography and (2) noncontrast computed tomography and computed tomographic angiography performed on admission within 6 hours after onset of symptoms. We defined a binary outcome (secondary neurological deterioration versus no secondary deterioration). As secondary neurological deterioration, we defined (1) early hemicraniectomy under standardized criteria or (2) secondary decrease of Glasgow Coma Scale of >3 points, both within the first 48 hours after symptom onset. Of 182 patients with spontaneous intracerebral hemorrhage, 37 (20.3%) presented with BS and 39 (21.4%) with SS. Of the 81 patients with secondary deterioration, 31 (38.3%) had BS and SS on admission. Multivariable logistic regression analysis identified hematoma volume (odds ratio, 1.07 per mL; P≤0.001), intraventricular hemorrhage (odds ratio, 3.08; P=0.008), and the presence of BS (odds ratio, 11.47; P≤0.001) as independent predictors of neurological deterioration. The BS, which is obtainable in noncontrast computed tomography, shows a high correlation with the computed tomographic angiography SS and is a reliable predictor of secondary neurological deterioration after spontaneous intracerebral hemorrhage. © 2016 American Heart Association, Inc.
Templin, Christian; Zweigerdt, Robert; Schwanke, Kristin; Olmer, Ruth; Ghadri, Jelena-Rima; Emmert, Maximilian Y; Müller, Ennio; Küest, Silke M; Cohrs, Susan; Schibli, Roger; Kronen, Peter; Hilbe, Monika; Reinisch, Andreas; Strunk, Dirk; Haverich, Axel; Hoerstrup, Simon; Lüscher, Thomas F; Kaufmann, Philipp A; Landmesser, Ulf; Martin, Ulrich
2012-07-24
Evaluation of novel cellular therapies in large-animal models and patients is currently hampered by the lack of imaging approaches that allow for long-term monitoring of viable transplanted cells. In this study, sodium iodide symporter (NIS) transgene imaging was evaluated as an approach to follow in vivo survival, engraftment, and distribution of human-induced pluripotent stem cell (hiPSC) derivatives in a pig model of myocardial infarction. Transgenic hiPSC lines stably expressing a fluorescent reporter and NIS (NIS(pos)-hiPSCs) were established. Iodide uptake, efflux, and viability of NIS(pos)-hiPSCs were assessed in vitro. Ten (±2) days after induction of myocardial infarction by transient occlusion of the left anterior descending artery, catheter-based intramyocardial injection of NIS(pos)-hiPSCs guided by 3-dimensional NOGA mapping was performed. Dual-isotope single photon emission computed tomographic/computed tomographic imaging was applied with the use of (123)I to follow donor cell survival and distribution and with the use of (99m)TC-tetrofosmin for perfusion imaging. In vitro, iodide uptake in NIS(pos)-hiPSCs was increased 100-fold above that of nontransgenic controls. In vivo, viable NIS(pos)-hiPSCs could be visualized for up to 15 weeks. Immunohistochemistry demonstrated that hiPSC-derived endothelial cells contributed to vascularization. Up to 12 to 15 weeks after transplantation, no teratomas were detected. This study describes for the first time the feasibility of repeated long-term in vivo imaging of viability and tissue distribution of cellular grafts in large animals. Moreover, this is the first report demonstrating vascular differentiation and long-term engraftment of hiPSCs in a large-animal model of myocardial infarction. NIS(pos)-hiPSCs represent a valuable tool to monitor and improve current cellular treatment strategies in clinically relevant animal models.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Craciunescu, Teddy, E-mail: teddy.craciunescu@jet.uk; Tiseanu, Ion; Zoita, Vasile
The Joint European Torus (JET) neutron profile monitor ensures 2D coverage of the gamma and neutron emissive region that enables tomographic reconstruction. Due to the availability of only two projection angles and to the coarse sampling, tomographic inversion is a limited data set problem. Several techniques have been developed for tomographic reconstruction of the 2-D gamma and neutron emissivity on JET, but the problem of evaluating the errors associated with the reconstructed emissivity profile is still open. The reconstruction technique based on the maximum likelihood principle, that proved already to be a powerful tool for JET tomography, has been usedmore » to develop a method for the numerical evaluation of the statistical properties of the uncertainties in gamma and neutron emissivity reconstructions. The image covariance calculation takes into account the additional techniques introduced in the reconstruction process for tackling with the limited data set (projection resampling, smoothness regularization depending on magnetic field). The method has been validated by numerically simulations and applied to JET data. Different sources of artefacts that may significantly influence the quality of reconstructions and the accuracy of variance calculation have been identified.« less
Computed tomographic findings of cerebral fat embolism following multiple bone fractures.
Law, Huong Ling; Wong, Siong Lung; Tan, Suzet
2013-02-01
Fat embolism to the lungs and brain is an uncommon complication following fractures. Few reports with descriptions of computed tomographic (CT) findings of emboli to the brain or cerebral fat embolism are available. We report a case of cerebral fat embolism following multiple skeletal fractures and present its CT findings here.
Computed tomographic contrast tenography of the digital flexor tendon sheath of the equine hindlimb.
Agass, Rachel; Dixon, Jonathon; Fraser, Barny
2018-05-01
Pre-surgical investigation of digital flexor tendon sheath pathology remains challenging with current standard imaging techniques. The aim of this prospective, anatomical, pilot study was to describe the anatomy of the equine hind limb digital flexor tendon sheath using a combination of computed tomography (CT) and computed tomographic contrast tenography in clinically normal cadaver limbs. Ten pairs of hind limbs with no external abnormalities were examined from the level of the tarsometatarsal joint distally. Limbs initially underwent non-contrast CT examination using 120 kVp, 300 mAs, and 1.5 mm slice thickness. Sixty millilitres of ioversol iodinated contrast media and saline (final concentration 100 mg/ml) were injected using a basilar sesamoidean approach. The computed tomographic contrast tenography examination was then repeated, before dissection of the specimens to compare gross and imaging findings. The combined CT and computed tomographic contrast tenography examinations provided excellent anatomical detail of intra-thecal structures. The borders of the superficial and deep digital flexor tendons, and the manica flexoria were consistently identifiable in all limbs. Detailed anatomy including that of the mesotenons, two of which are previously undescribed, and the plantar annular ligament were also consistently identifiable. Dissection of all 10 pairs of limbs revealed there to be no pathology, in accordance with the imaging findings. In conclusion, the combination of CT and computed tomographic contrast tenography may be useful adjunctive diagnostic techniques to define digital flexor tendon sheath pathology prior to surgical exploration in horses. © 2017 American College of Veterinary Radiology.
Diaz, Alejandro A; Estépar, Raul San José; Washko, George R
2016-01-01
Computed tomographic measures of central airway morphology have been used in clinical, epidemiologic, and genetic investigation as an inference of the presence and severity of small-airway disease in smokers. Although several association studies have brought us to believe that these computed tomographic measures reflect airway remodeling, a careful review of such data and more recent evidence may reveal underappreciated complexity to these measures and limitations that prompt us to question that belief. This Perspective offers a review of seminal papers and alternative explanations of their data in the light of more recent evidence. The relationships between airway morphology and lung function are observed in subjects who never smoked, implying that native airway structure indeed contributes to lung function; computed tomographic measures of central airways such as wall area, lumen area, and total bronchial area are smaller in smokers with chronic obstructive pulmonary disease versus those without chronic obstructive pulmonary disease; and the airways are smaller as disease severity increases. The observations suggest that (1) native airway morphology likely contributes to the relationships between computed tomographic measures of airways and lung function; and (2) the presence of smaller airways in those with chronic obstructive pulmonary disease versus those without chronic obstructive pulmonary disease as well as their decrease with disease severity suggests that smokers with chronic obstructive pulmonary disease may simply have smaller airways to begin with, which put them at greater risk for the development of smoking-related disease.
Optimization of tomographic reconstruction workflows on geographically distributed resources
Bicer, Tekin; Gursoy, Doga; Kettimuthu, Rajkumar; ...
2016-01-01
New technological advancements in synchrotron light sources enable data acquisitions at unprecedented levels. This emergent trend affects not only the size of the generated data but also the need for larger computational resources. Although beamline scientists and users have access to local computational resources, these are typically limited and can result in extended execution times. Applications that are based on iterative processing as in tomographic reconstruction methods require high-performance compute clusters for timely analysis of data. Here, time-sensitive analysis and processing of Advanced Photon Source data on geographically distributed resources are focused on. Two main challenges are considered: (i) modelingmore » of the performance of tomographic reconstruction workflows and (ii) transparent execution of these workflows on distributed resources. For the former, three main stages are considered: (i) data transfer between storage and computational resources, (i) wait/queue time of reconstruction jobs at compute resources, and (iii) computation of reconstruction tasks. These performance models allow evaluation and estimation of the execution time of any given iterative tomographic reconstruction workflow that runs on geographically distributed resources. For the latter challenge, a workflow management system is built, which can automate the execution of workflows and minimize the user interaction with the underlying infrastructure. The system utilizes Globus to perform secure and efficient data transfer operations. The proposed models and the workflow management system are evaluated by using three high-performance computing and two storage resources, all of which are geographically distributed. Workflows were created with different computational requirements using two compute-intensive tomographic reconstruction algorithms. Experimental evaluation shows that the proposed models and system can be used for selecting the optimum resources, which in turn can provide up to 3.13× speedup (on experimented resources). Furthermore, the error rates of the models range between 2.1 and 23.3% (considering workflow execution times), where the accuracy of the model estimations increases with higher computational demands in reconstruction tasks.« less
Optimization of tomographic reconstruction workflows on geographically distributed resources
Bicer, Tekin; Gürsoy, Doǧa; Kettimuthu, Rajkumar; De Carlo, Francesco; Foster, Ian T.
2016-01-01
New technological advancements in synchrotron light sources enable data acquisitions at unprecedented levels. This emergent trend affects not only the size of the generated data but also the need for larger computational resources. Although beamline scientists and users have access to local computational resources, these are typically limited and can result in extended execution times. Applications that are based on iterative processing as in tomographic reconstruction methods require high-performance compute clusters for timely analysis of data. Here, time-sensitive analysis and processing of Advanced Photon Source data on geographically distributed resources are focused on. Two main challenges are considered: (i) modeling of the performance of tomographic reconstruction workflows and (ii) transparent execution of these workflows on distributed resources. For the former, three main stages are considered: (i) data transfer between storage and computational resources, (i) wait/queue time of reconstruction jobs at compute resources, and (iii) computation of reconstruction tasks. These performance models allow evaluation and estimation of the execution time of any given iterative tomographic reconstruction workflow that runs on geographically distributed resources. For the latter challenge, a workflow management system is built, which can automate the execution of workflows and minimize the user interaction with the underlying infrastructure. The system utilizes Globus to perform secure and efficient data transfer operations. The proposed models and the workflow management system are evaluated by using three high-performance computing and two storage resources, all of which are geographically distributed. Workflows were created with different computational requirements using two compute-intensive tomographic reconstruction algorithms. Experimental evaluation shows that the proposed models and system can be used for selecting the optimum resources, which in turn can provide up to 3.13× speedup (on experimented resources). Moreover, the error rates of the models range between 2.1 and 23.3% (considering workflow execution times), where the accuracy of the model estimations increases with higher computational demands in reconstruction tasks. PMID:27359149
Optimization of tomographic reconstruction workflows on geographically distributed resources
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bicer, Tekin; Gursoy, Doga; Kettimuthu, Rajkumar
New technological advancements in synchrotron light sources enable data acquisitions at unprecedented levels. This emergent trend affects not only the size of the generated data but also the need for larger computational resources. Although beamline scientists and users have access to local computational resources, these are typically limited and can result in extended execution times. Applications that are based on iterative processing as in tomographic reconstruction methods require high-performance compute clusters for timely analysis of data. Here, time-sensitive analysis and processing of Advanced Photon Source data on geographically distributed resources are focused on. Two main challenges are considered: (i) modelingmore » of the performance of tomographic reconstruction workflows and (ii) transparent execution of these workflows on distributed resources. For the former, three main stages are considered: (i) data transfer between storage and computational resources, (i) wait/queue time of reconstruction jobs at compute resources, and (iii) computation of reconstruction tasks. These performance models allow evaluation and estimation of the execution time of any given iterative tomographic reconstruction workflow that runs on geographically distributed resources. For the latter challenge, a workflow management system is built, which can automate the execution of workflows and minimize the user interaction with the underlying infrastructure. The system utilizes Globus to perform secure and efficient data transfer operations. The proposed models and the workflow management system are evaluated by using three high-performance computing and two storage resources, all of which are geographically distributed. Workflows were created with different computational requirements using two compute-intensive tomographic reconstruction algorithms. Experimental evaluation shows that the proposed models and system can be used for selecting the optimum resources, which in turn can provide up to 3.13× speedup (on experimented resources). Furthermore, the error rates of the models range between 2.1 and 23.3% (considering workflow execution times), where the accuracy of the model estimations increases with higher computational demands in reconstruction tasks.« less
NASA Astrophysics Data System (ADS)
Tornai, Martin P.; Bowsher, James E.; Archer, Caryl N.; Peter, Jörg; Jaszczak, Ronald J.; MacDonald, Lawrence R.; Patt, Bradley E.; Iwanczyk, Jan S.
2003-01-01
A novel tomographic gantry was designed, built and initially evaluated for single photon emission imaging of metabolically active lesions in the pendant breast and near chest wall. Initial emission imaging measurements with breast lesions of various uptake ratios are presented. Methods: A prototype tomograph was constructed utilizing a compact gamma camera having a field-of-view of <13×13 cm 2 with arrays of 2×2×6 mm 3 quantized NaI(Tl) scintillators coupled to position sensitive PMTs. The camera was mounted on a radially oriented support with 6 cm variable radius-of-rotation. This unit is further mounted on a goniometric cradle providing polar motion, and in turn mounted on an azimuthal rotation stage capable of indefinite vertical axis-of-rotation about the central rotation axis (RA). Initial measurements with isotopic Tc-99 m (140 keV) to evaluate the system include acquisitions with various polar tilt angles about the RA. Tomographic measurements were made of a frequency and resolution cold-rod phantom filled with aqueous Tc-99 m. Tomographic and planar measurements of 0.6 and 1.0 cm diameter fillable spheres in an available ˜950 ml hemi-ellipsoidal (uncompressed) breast phantom attached to a life-size anthropomorphic torso phantom with lesion:breast-and-body:cardiac-and-liver activity concentration ratios of 11:1:19 were compared. Various photopeak energy windows from 10-30% widths were obtained, along with a 35% scatter window below a 15% photopeak window from the list mode data. Projections with all photopeak window and camera tilt conditions were reconstructed with an ordered subsets expectation maximization (OSEM) algorithm capable of reconstructing arbitrary tomographic orbits. Results: As iteration number increased for the tomographically measured data at all polar angles, contrasts increased while signal-to-noise ratios (SNRs) decreased in the expected way with OSEM reconstruction. The rollover between contrast improvement and SNR degradation of the lesion occurred at two to three iterations. The reconstructed tomographic data yielded SNRs with or without scatter correction that were >9 times better than the planar scans. There was up to a factor of ˜2.5 increase in total primary and scatter contamination in the photopeak window with increasing tilt angle from 15° to 45°, consistent with more direct line-of-sight of myocardial and liver activity with increased camera polar angle. Conclusion: This new, ultra-compact, dedicated tomographic imaging system has the potential of providing valuable, fully 3D functional information about small, otherwise indeterminate breast lesions as an adjunct to diagnostic mammography.
Intravascular lymphomatosis presenting as acute hemispheric dysfunction.
Hwang, Woo Sub; Jung, Chul Won; Ko, Young Hye; Seo, Sang Won; Na, Duk L
2012-11-01
Intravascular lymphomatosis (IVL) is known to affect both hemispheres of the brain and manifests clinically as seizures or dementia. To our knowledge, there have been no cases in which acute hemispheric dysfunction is manifested in IVL. We present a 54-year-old man who showed steroid responsive acute hemispheric dysfunction. A technetium 99m-ethyl cysteinate dimer single-photon emission computed tomographic scan of the brain revealed hypoperfusion in the right hemisphere. The bone marrow biopsy specimen confirmed malignant lymphoid cells in vessels, which suggested IVL. Our case signifies the diversity of clinical manifestations in IVL. Copyright © 2012. Published by Elsevier Inc.
TomoBank: a tomographic data repository for computational x-ray science
De Carlo, Francesco; Gürsoy, Doğa; Ching, Daniel J.; ...
2018-02-08
There is a widening gap between the fast advancement of computational methods for tomographic reconstruction and their successful implementation in production software at various synchrotron facilities. This is due in part to the lack of readily available instrument datasets and phantoms representative of real materials for validation and comparison of new numerical methods. Recent advancements in detector technology made sub-second and multi-energy tomographic data collection possible [1], but also increased the demand to develop new reconstruction methods able to handle in-situ [2] and dynamic systems [3] that can be quickly incorporated in beamline production software [4]. The X-ray Tomography Datamore » Bank, tomoBank, provides a repository of experimental and simulated datasets with the aim to foster collaboration among computational scientists, beamline scientists, and experimentalists and to accelerate the development and implementation of tomographic reconstruction methods for synchrotron facility production software by providing easy access to challenging dataset and their descriptors.« less
Siontis, George CM; Mavridis, Dimitris; Greenwood, John P; Coles, Bernadette; Nikolakopoulou, Adriani; Jüni, Peter; Salanti, Georgia
2018-01-01
Abstract Objective To evaluate differences in downstream testing, coronary revascularisation, and clinical outcomes following non-invasive diagnostic modalities used to detect coronary artery disease. Design Systematic review and network meta-analysis. Data sources Medline, Medline in process, Embase, Cochrane Library for clinical trials, PubMed, Web of Science, SCOPUS, WHO International Clinical Trials Registry Platform, and Clinicaltrials.gov. Eligibility criteria for selecting studies Diagnostic randomised controlled trials comparing non-invasive diagnostic modalities in patients presenting with symptoms suggestive of low risk acute coronary syndrome or stable coronary artery disease. Data synthesis A random effects network meta-analysis synthesised available evidence from trials evaluating the effect of non-invasive diagnostic modalities on downstream testing and patient oriented outcomes in patients with suspected coronary artery disease. Modalities included exercise electrocardiograms, stress echocardiography, single photon emission computed tomography-myocardial perfusion imaging, real time myocardial contrast echocardiography, coronary computed tomographic angiography, and cardiovascular magnetic resonance. Unpublished outcome data were obtained from 11 trials. Results 18 trials of patients with low risk acute coronary syndrome (n=11 329) and 12 trials of those with suspected stable coronary artery disease (n=22 062) were included. Among patients with low risk acute coronary syndrome, stress echocardiography, cardiovascular magnetic resonance, and exercise electrocardiograms resulted in fewer invasive referrals for coronary angiography than coronary computed tomographic angiography (odds ratio 0.28 (95% confidence interval 0.14 to 0.57), 0.32 (0.15 to 0.71), and 0.53 (0.28 to 1.00), respectively). There was no effect on the subsequent risk of myocardial infarction, but estimates were imprecise. Heterogeneity and inconsistency were low. In patients with suspected stable coronary artery disease, an initial diagnostic strategy of stress echocardiography or single photon emission computed tomography-myocardial perfusion imaging resulted in fewer downstream tests than coronary computed tomographic angiography (0.24 (0.08 to 0.74) and 0.57 (0.37 to 0.87), respectively). However, exercise electrocardiograms yielded the highest downstream testing rate. Estimates for death and myocardial infarction were imprecise without clear discrimination between strategies. Conclusions For patients with low risk acute coronary syndrome, an initial diagnostic strategy of stress echocardiography or cardiovascular magnetic resonance is associated with fewer referrals for invasive coronary angiography and revascularisation procedures than non-invasive anatomical testing, without apparent impact on the future risk of myocardial infarction. For suspected stable coronary artery disease, there was no clear discrimination between diagnostic strategies regarding the subsequent need for invasive coronary angiography, and differences in the risk of myocardial infarction cannot be ruled out. Systematic review registration PROSPERO registry no CRD42016049442. PMID:29467161
New Possibilities of Positron-Emission Tomography
NASA Astrophysics Data System (ADS)
Volobuev, A. N.
2018-01-01
The reasons for the emergence of the angular distribution of photons generated as a result of annihilation of an electron and a positron in a positron-emission tomograph are investigated. It is shown that the angular distribution of the radiation intensity (i.e., the probability of photon emission at different angles) is a consequence of the Doppler effect in the center-of-mass reference system of the electron and the positron. In the reference frame attached to the electron, the angular distribution of the number of emitted photons does not exists but is replaced by the Doppler shift of the frequency of photons. The results obtained in this study make it possible to extend the potentialities of the positron-emission tomograph in the diagnostics of diseases and to obtain additional mechanical characteristics of human tissues, such as density and viscosity.
Positron Emission Tomography: Principles, Technology, and Recent Developments
NASA Astrophysics Data System (ADS)
Ziegler, Sibylle I.
2005-04-01
Positron emission tomography (PET) is a nuclear medical imaging technique for quantitative measurement of physiologic parameters in vivo (an overview of principles and applications can be found in [P.E. Valk, et al., eds. Positron Emission Tomography. Basic Science and Clinical Practice. 2003, Springer: Heidelberg]), based on the detection of small amounts of posi-tron-emitter-labelled biologic molecules. Various radiotracers are available for neuro-logical, cardiological, and oncological applications in the clinic and in research proto-cols. This overview describes the basic principles, technology, and recent develop-ments in PET, followed by a section on the development of a tomograph with ava-lanche photodiodes dedicated for small animal imaging as an example of efforts in the domain of high resolution tomographs.
An Analysis for Capital Expenditure Decisions at a Naval Regional Medical Center.
1981-12-01
Service Equipment Review Committee 1. Portable defibrilator Computed tomographic scanner and cardioscope 2. ECG cart Automated blood cell counter 3. Gas...system sterilizer Gas system sterilizer 4. Automated blood cell Portable defibrilator and counter cardioscope 5. Computed tomographic ECG cart scanner...dictating and automated typing) systems. e. Filing equipment f. Automatic data processing equipment including data communications equipment. g
Kubo, S; Nakata, H; Sugauchi, Y; Yokota, N; Yoshimine, T
2000-05-01
The preoperative localization of superficial intracranial lesions is often necessary for accurate burr hole placement or craniotomy siting. It is not always easy, however, to localize the lesions over the scalp working only from computed tomographic images. We developed a simple method for such localization using a laser pointer during the preoperative computed tomographic examination. The angle of incidence, extending from a point on the scalp to the center of the computed tomographic image, is measured by the software included with the scanner. In the gantry, at the same angle as on the image, a laser is beamed from a handmade projector onto the patient's scalp toward the center of the gantry. The point illuminated on the patient's head corresponds to that on the image. The device and the method are described in detail herein. We applied this technique to mark the area for the craniotomy before surgery in five patients with superficial brain tumors. At the time of surgery, it was confirmed that the tumors were circumscribed precisely. The technique is easy to perform and useful in the preoperative planning for a craniotomy. In addition, the device is easily constructed and inexpensive.
TomoBank: a tomographic data repository for computational x-ray science
NASA Astrophysics Data System (ADS)
De Carlo, Francesco; Gürsoy, Doğa; Ching, Daniel J.; Joost Batenburg, K.; Ludwig, Wolfgang; Mancini, Lucia; Marone, Federica; Mokso, Rajmund; Pelt, Daniël M.; Sijbers, Jan; Rivers, Mark
2018-03-01
There is a widening gap between the fast advancement of computational methods for tomographic reconstruction and their successful implementation in production software at various synchrotron facilities. This is due in part to the lack of readily available instrument datasets and phantoms representative of real materials for validation and comparison of new numerical methods. Recent advancements in detector technology have made sub-second and multi-energy tomographic data collection possible (Gibbs et al 2015 Sci. Rep. 5 11824), but have also increased the demand to develop new reconstruction methods able to handle in situ (Pelt and Batenburg 2013 IEEE Trans. Image Process. 22 5238-51) and dynamic systems (Mohan et al 2015 IEEE Trans. Comput. Imaging 1 96-111) that can be quickly incorporated in beamline production software (Gürsoy et al 2014 J. Synchrotron Radiat. 21 1188-93). The x-ray tomography data bank, tomoBank, provides a repository of experimental and simulated datasets with the aim to foster collaboration among computational scientists, beamline scientists, and experimentalists and to accelerate the development and implementation of tomographic reconstruction methods for synchrotron facility production software by providing easy access to challenging datasets and their descriptors.
Trace: a high-throughput tomographic reconstruction engine for large-scale datasets.
Bicer, Tekin; Gürsoy, Doğa; Andrade, Vincent De; Kettimuthu, Rajkumar; Scullin, William; Carlo, Francesco De; Foster, Ian T
2017-01-01
Modern synchrotron light sources and detectors produce data at such scale and complexity that large-scale computation is required to unleash their full power. One of the widely used imaging techniques that generates data at tens of gigabytes per second is computed tomography (CT). Although CT experiments result in rapid data generation, the analysis and reconstruction of the collected data may require hours or even days of computation time with a medium-sized workstation, which hinders the scientific progress that relies on the results of analysis. We present Trace, a data-intensive computing engine that we have developed to enable high-performance implementation of iterative tomographic reconstruction algorithms for parallel computers. Trace provides fine-grained reconstruction of tomography datasets using both (thread-level) shared memory and (process-level) distributed memory parallelization. Trace utilizes a special data structure called replicated reconstruction object to maximize application performance. We also present the optimizations that we apply to the replicated reconstruction objects and evaluate them using tomography datasets collected at the Advanced Photon Source. Our experimental evaluations show that our optimizations and parallelization techniques can provide 158× speedup using 32 compute nodes (384 cores) over a single-core configuration and decrease the end-to-end processing time of a large sinogram (with 4501 × 1 × 22,400 dimensions) from 12.5 h to <5 min per iteration. The proposed tomographic reconstruction engine can efficiently process large-scale tomographic data using many compute nodes and minimize reconstruction times.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hammeschlag, S.B.; Hughes, S.; O'Reilly, G.V.
Orbital blow-out fractures were experimentally created in eight human cadavers. Each orbit underwent conventional radiographic studies, complex motion tomography, and computed tomographic examinations. A comparison of the three modalities was made. Anatomical correlation was obtained by dissecting the orbits. The significance of medial-wall fractures and enophthalmos is discussed. Limitation of inferior rectus muscle mobility is thought to be a result of muscle kinking associated with orbital fat-pad prolapse at the fracture site, rather than muscle incarceration. Blow-out fractures should be evaluated by computed tomographic computer reformations in the oblique sagittal plane.
Classification of JET Neutron and Gamma Emissivity Profiles
NASA Astrophysics Data System (ADS)
Craciunescu, T.; Murari, A.; Kiptily, V.; Vega, J.; Contributors, JET
2016-05-01
In thermonuclear plasmas, emission tomography uses integrated measurements along lines of sight (LOS) to determine the two-dimensional (2-D) spatial distribution of the volume emission intensity. Due to the availability of only a limited number views and to the coarse sampling of the LOS, the tomographic inversion is a limited data set problem. Several techniques have been developed for tomographic reconstruction of the 2-D gamma and neutron emissivity on JET. In specific experimental conditions the availability of LOSs is restricted to a single view. In this case an explicit reconstruction of the emissivity profile is no longer possible. However, machine learning classification methods can be used in order to derive the type of the distribution. In the present approach the classification is developed using the theory of belief functions which provide the support to fuse the results of independent clustering and supervised classification. The method allows to represent the uncertainty of the results provided by different independent techniques, to combine them and to manage possible conflicts.
Evaluation of a Multicore-Optimized Implementation for Tomographic Reconstruction
Agulleiro, Jose-Ignacio; Fernández, José Jesús
2012-01-01
Tomography allows elucidation of the three-dimensional structure of an object from a set of projection images. In life sciences, electron microscope tomography is providing invaluable information about the cell structure at a resolution of a few nanometres. Here, large images are required to combine wide fields of view with high resolution requirements. The computational complexity of the algorithms along with the large image size then turns tomographic reconstruction into a computationally demanding problem. Traditionally, high-performance computing techniques have been applied to cope with such demands on supercomputers, distributed systems and computer clusters. In the last few years, the trend has turned towards graphics processing units (GPUs). Here we present a detailed description and a thorough evaluation of an alternative approach that relies on exploitation of the power available in modern multicore computers. The combination of single-core code optimization, vector processing, multithreading and efficient disk I/O operations succeeds in providing fast tomographic reconstructions on standard computers. The approach turns out to be competitive with the fastest GPU-based solutions thus far. PMID:23139768
Li, Qiao; Gao, Xinyi; Yao, Zhenwei; Feng, Xiaoyuan; He, Huijin; Xue, Jing; Gao, Peiyi; Yang, Lumeng; Cheng, Xin; Chen, Weijian; Yang, Yunjun
2017-09-01
Permeability surface (PS) on computed tomographic perfusion reflects blood-brain barrier permeability and is related to hemorrhagic transformation (HT). HT of deep middle cerebral artery (MCA) territory can occur after recanalization of proximal large-vessel occlusion. We aimed to determine the relationship between HT and PS of deep MCA territory. We retrospectively reviewed 70 consecutive acute ischemic stroke patients presenting with occlusion of the distal internal carotid artery or M1 segment of the MCA. All patients underwent computed tomographic perfusion within 6 hours after symptom onset. Computed tomographic perfusion data were postprocessed to generate maps of different perfusion parameters. Risk factors were identified for increased deep MCA territory PS. Receiver operating characteristic curve analysis was performed to calculate the optimal PS threshold to predict HT of deep MCA territory. Increased PS was associated with HT of deep MCA territory. After adjustments for age, sex, onset time to computed tomographic perfusion, and baseline National Institutes of Health Stroke Scale, poor collateral status (odds ratio, 7.8; 95% confidence interval, 1.67-37.14; P =0.009) and proximal MCA-M1 occlusion (odds ratio, 4.12; 95% confidence interval, 1.03-16.52; P =0.045) were independently associated with increased deep MCA territory PS. Relative PS most accurately predicted HT of deep MCA territory (area under curve, 0.94; optimal threshold, 2.89). Increased PS can predict HT of deep MCA territory after recanalization therapy for cerebral proximal large-vessel occlusion. Proximal MCA-M1 complete occlusion and distal internal carotid artery occlusion in conjunction with poor collaterals elevate deep MCA territory PS. © 2017 American Heart Association, Inc.
Kubo, N
1995-04-01
To improve the quality of single-photon emission computed tomographic (SPECT) images, a restoration filter has been developed. This filter was designed according to practical "least squares filter" theory. It is necessary to know the object power spectrum and the noise power spectrum. The power spectrum is estimated from the power spectrum of a projection, when the high-frequency power spectrum of a projection is adequately approximated as a polynomial exponential expression. A study of the restoration with the filter based on a projection power spectrum was conducted, and compared with that of the "Butterworth" filtering method (cut-off frequency of 0.15 cycles/pixel), and "Wiener" filtering (signal-to-noise power spectrum ratio was a constant). Normalized mean-squared errors (NMSE) of the phantom, two line sources located in a 99mTc filled cylinder, were used. NMSE of the "Butterworth" filter, "Wiener" filter, and filtering based on a power spectrum were 0.77, 0.83, and 0.76 respectively. Clinically, brain SPECT images utilizing this new restoration filter improved the contrast. Thus, this filter may be useful in diagnosis of SPECT images.
Computed tomographic findings of trichuriasis
Tokmak, Naime; Koc, Zafer; Ulusan, Serife; Koltas, Ismail Soner; Bal, Nebil
2006-01-01
In this report, we present computed tomographic findings of colonic trichuriasis. The patient was a 75-year-old man who complained of abdominal pain, and weight loss. Diagnosis was achieved by colonoscopic biopsy. Abdominal computed tomography showed irregular and nodular thickening of the wall of the cecum and ascending colon. Although these findings are nonspecific, they may be one of the findings of trichuriasis. These findings, confirmed by pathologic analysis of the biopsied tissue and Kato-Katz parasitological stool flotation technique, revealed adult Trichuris. To our knowledge, this is the first report of colonic trichuriasis indicated by computed tomography. PMID:16830393
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kramar, M.; Lin, H.; Tomczyk, S., E-mail: kramar@cua.edu, E-mail: lin@ifa.hawaii.edu, E-mail: tomczyk@ucar.edu
We present the first direct “observation” of the global-scale, 3D coronal magnetic fields of Carrington Rotation (CR) Cycle 2112 using vector tomographic inversion techniques. The vector tomographic inversion uses measurements of the Fe xiii 10747 Å Hanle effect polarization signals by the Coronal Multichannel Polarimeter (CoMP) and 3D coronal density and temperature derived from scalar tomographic inversion of Solar Terrestrial Relations Observatory (STEREO)/Extreme Ultraviolet Imager (EUVI) coronal emission lines (CELs) intensity images as inputs to derive a coronal magnetic field model that best reproduces the observed polarization signals. While independent verifications of the vector tomography results cannot be performed, wemore » compared the tomography inverted coronal magnetic fields with those constructed by magnetohydrodynamic (MHD) simulations based on observed photospheric magnetic fields of CR 2112 and 2113. We found that the MHD model for CR 2112 is qualitatively consistent with the tomography inverted result for most of the reconstruction domain except for several regions. Particularly, for one of the most noticeable regions, we found that the MHD simulation for CR 2113 predicted a model that more closely resembles the vector tomography inverted magnetic fields. In another case, our tomographic reconstruction predicted an open magnetic field at a region where a coronal hole can be seen directly from a STEREO-B/EUVI image. We discuss the utilities and limitations of the tomographic inversion technique, and present ideas for future developments.« less
Isaacson, Brandon; Kutz, Joe Walter; Mendelsohn, Dianne; Roland, Peter S
2009-04-01
To demonstrate the use of computed tomographic (CT) venography in selecting a surgical approach for cholesterol granulomas. Retrospective case review. Tertiary referral center. Three patients presented with symptomatic petrous apex cholesterol granulomas with extensive bone erosion involving the jugular fossa. Computed tomographic venography was performed on each patient before selecting a surgical approach for drainage. Localization of the jugular bulb in relation to the petrous carotid artery and basal turn of the cochlea was ascertained in each subject. Three patients with large symptomatic cholesterol granulomas were identified. Conventional CT demonstrated extensive bone erosion involving the jugular fossa in each patient. The location of the jugular bulb and its proximity to the petrous carotid artery and basal turn of the cochlea could not be determined with conventional temporal bone CT and magnetic resonance imaging. Computed tomographic venography provided the exact location of the jugular bulb in all 3 patients. The favorable position of the jugular bulb in all 3 cases permitted drainage of these lesions using an infracochlear approach. Computed tomographic venography provided invaluable information in 3 patients with large symptomatic cholesterol granulomas. All 3 patients were previously thought to be unsuitable candidates for an infracochlear or infralabyrinthine approach because of the unknown location of the jugular bulb.
NASA Technical Reports Server (NTRS)
Yin, L. I.; Trombka, J. I.; Bielefeld, M. J.; Seltzer, S. M.
1984-01-01
The results of two computer simulations demonstrate the feasibility of using the nonoverlapping redundant array (NORA) to form three-dimensional images of objects with X-rays. Pinholes admit the X-rays to nonoverlapping points on a detector. The object is reconstructed in the analog mode by optical correlation and in the digital mode by tomographic computations. Trials were run with a stick-figure pyramid and extended objects with out-of-focus backgrounds. Substitution of spherical optical lenses for the pinholes increased the light transmission sufficiently that objects could be easily viewed in a dark room. Out-of-focus aberrations in tomographic reconstruction could be eliminated using Chang's (1976) algorithm.
Recent Developments in Positron Emission Tomography (PET) Instrumentation
DOE R&D Accomplishments Database
Derenzo, S. E.; Budinger, T. F.
1986-04-01
This paper presents recent detector developments and perspectives for positron emission tomography (PET) instrumentation used for medical research, as well as the physical processes in positron annihilation, photon scattering and detection, tomograph design considerations, and the potentials for new advances in detectors.
The Tomographic Ionized-Carbon Mapping Experiment (TIME) CII Imaging Spectrometer
NASA Astrophysics Data System (ADS)
Staniszewski, Z.; Bock, J. J.; Bradford, C. M.; Brevik, J.; Cooray, A.; Gong, Y.; Hailey-Dunsheath, S.; O'Brient, R.; Santos, M.; Shirokoff, E.; Silva, M.; Zemcov, M.
2014-09-01
The Tomographic Ionized-Carbon Mapping Experiment (TIME) and TIME-Pilot are proposed imaging spectrometers to measure reionization and large scale structure at redshifts 5-9. We seek to exploit the 158 restframe emission of [CII], which becomes measurable at 200-300 GHz at reionization redshifts. Here we describe the scientific motivation, give an overview of the proposed instrument, and highlight key technological developments underway to enable these measurements.
DOE Office of Scientific and Technical Information (OSTI.GOV)
PELT, DANIEL
2017-04-21
Small Python package to compute tomographic reconstructions using a reconstruction method published in: Pelt, D.M., & De Andrade, V. (2017). Improved tomographic reconstruction of large-scale real-world data by filter optimization. Advanced Structural and Chemical Imaging 2: 17; and Pelt, D. M., & Batenburg, K. J. (2015). Accurately approximating algebraic tomographic reconstruction by filtered backprojection. In Proceedings of The 13th International Meeting on Fully Three-Dimensional Image Reconstruction in Radiology and Nuclear Medicine (pp. 158-161).
Anthropomorphic thorax phantom for cardio-respiratory motion simulation in tomographic imaging
NASA Astrophysics Data System (ADS)
Bolwin, Konstantin; Czekalla, Björn; Frohwein, Lynn J.; Büther, Florian; Schäfers, Klaus P.
2018-02-01
Patient motion during medical imaging using techniques such as computed tomography (CT), magnetic resonance imaging (MRI), positron emission tomography (PET), or single emission computed tomography (SPECT) is well known to degrade images, leading to blurring effects or severe artifacts. Motion correction methods try to overcome these degrading effects. However, they need to be validated under realistic conditions. In this work, a sophisticated anthropomorphic thorax phantom is presented that combines several aspects of a simulator for cardio-respiratory motion. The phantom allows us to simulate various types of cardio-respiratory motions inside a human-like thorax, including features such as inflatable lungs, beating left ventricular myocardium, respiration-induced motion of the left ventricle, moving lung lesions, and moving coronary artery plaques. The phantom is constructed to be MR-compatible. This means that we can not only perform studies in PET, SPECT and CT, but also inside an MRI system. The technical features of the anthropomorphic thorax phantom Wilhelm are presented with regard to simulating motion effects in hybrid emission tomography and radiotherapy. This is supplemented by a study on the detectability of small coronary plaque lesions in PET/CT under the influence of cardio-respiratory motion, and a study on the accuracy of left ventricular blood volumes.
Single-shot ultrafast tomographic imaging by spectral multiplexing
NASA Astrophysics Data System (ADS)
Matlis, N. H.; Axley, A.; Leemans, W. P.
2012-10-01
Computed tomography has profoundly impacted science, medicine and technology by using projection measurements scanned over multiple angles to permit cross-sectional imaging of an object. The application of computed tomography to moving or dynamically varying objects, however, has been limited by the temporal resolution of the technique, which is set by the time required to complete the scan. For objects that vary on ultrafast timescales, traditional scanning methods are not an option. Here we present a non-scanning method capable of resolving structure on femtosecond timescales by using spectral multiplexing of a single laser beam to perform tomographic imaging over a continuous range of angles simultaneously. We use this technique to demonstrate the first single-shot ultrafast computed tomography reconstructions and obtain previously inaccessible structure and position information for laser-induced plasma filaments. This development enables real-time tomographic imaging for ultrafast science, and offers a potential solution to the challenging problem of imaging through scattering surfaces.
Lynch, Rod; Pitson, Graham; Ball, David; Claude, Line; Sarrut, David
2013-01-01
To develop a reproducible definition for each mediastinal lymph node station based on the new TNM classification for lung cancer. This paper proposes an atlas using the new international lymph node map used in the seventh edition of the TNM classification for lung cancer. Four radiation oncologists and 1 diagnostic radiologist were involved in the project to put forward a reproducible radiologic description for the lung lymph node stations. The International Association for the Study of Lung Cancer lymph node definitions for stations 1 to 11 have been described and illustrated on axial computed tomographic scan images using a certified radiotherapy planning system. This atlas will assist both diagnostic radiologists and radiation oncologists in accurately defining the lymph node stations on computed tomographic scan in patients diagnosed with lung cancer. Copyright © 2013 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.
de Lima, Camila; Salomão Helou, Elias
2018-01-01
Iterative methods for tomographic image reconstruction have the computational cost of each iteration dominated by the computation of the (back)projection operator, which take roughly O(N 3 ) floating point operations (flops) for N × N pixels images. Furthermore, classical iterative algorithms may take too many iterations in order to achieve acceptable images, thereby making the use of these techniques unpractical for high-resolution images. Techniques have been developed in the literature in order to reduce the computational cost of the (back)projection operator to O(N 2 logN) flops. Also, incremental algorithms have been devised that reduce by an order of magnitude the number of iterations required to achieve acceptable images. The present paper introduces an incremental algorithm with a cost of O(N 2 logN) flops per iteration and applies it to the reconstruction of very large tomographic images obtained from synchrotron light illuminated data.
Post-processing methods of rendering and visualizing 3-D reconstructed tomographic images
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wong, S.T.C.
The purpose of this presentation is to discuss the computer processing techniques of tomographic images, after they have been generated by imaging scanners, for volume visualization. Volume visualization is concerned with the representation, manipulation, and rendering of volumetric data. Since the first digital images were produced from computed tomography (CT) scanners in the mid 1970s, applications of visualization in medicine have expanded dramatically. Today, three-dimensional (3D) medical visualization has expanded from using CT data, the first inherently digital source of 3D medical data, to using data from various medical imaging modalities, including magnetic resonance scanners, positron emission scanners, digital ultrasound,more » electronic and confocal microscopy, and other medical imaging modalities. We have advanced from rendering anatomy to aid diagnosis and visualize complex anatomic structures to planning and assisting surgery and radiation treatment. New, more accurate and cost-effective procedures for clinical services and biomedical research have become possible by integrating computer graphics technology with medical images. This trend is particularly noticeable in current market-driven health care environment. For example, interventional imaging, image-guided surgery, and stereotactic and visualization techniques are now stemming into surgical practice. In this presentation, we discuss only computer-display-based approaches of volumetric medical visualization. That is, we assume that the display device available is two-dimensional (2D) in nature and all analysis of multidimensional image data is to be carried out via the 2D screen of the device. There are technologies such as holography and virtual reality that do provide a {open_quotes}true 3D screen{close_quotes}. To confine the scope, this presentation will not discuss such approaches.« less
NASA Astrophysics Data System (ADS)
Petit, C.; Le Louarn, M.; Fusco, T.; Madec, P.-Y.
2011-09-01
Various tomographic control solutions have been proposed during the last decades to ensure efficient or even optimal closed-loop correction to tomographic Adaptive Optics (AO) concepts such as Laser Tomographic AO (LTAO), Multi-Conjugate AO (MCAO). The optimal solution, based on Linear Quadratic Gaussian (LQG) approach, as well as suboptimal but efficient solutions such as Pseudo-Open Loop Control (POLC) require multiple Matrix Vector Multiplications (MVM). Disregarding their respective performance, these efficient control solutions thus exhibit strong increase of on-line complexity and their implementation may become difficult in demanding cases. Among them, two cases are of particular interest. First, the system Real-Time Computer architecture and implementation is derived from past or present solutions and does not support multiple MVM. This is the case of the AO Facility which RTC architecture is derived from the SPARTA platform and inherits its simple MVM architecture, which does not fit with LTAO control solutions for instance. Second, considering future systems such as Extremely Large Telescopes, the number of degrees of freedom is twenty to one hundred times bigger than present systems. In these conditions, tomographic control solutions can hardly be used in their standard form and optimized implementation shall be considered. Single MVM tomographic control solutions represent a potential solution, and straightforward solutions such as Virtual Deformable Mirrors have been already proposed for LTAO but with tuning issues. We investigate in this paper the possibility to derive from tomographic control solutions, such as POLC or LQG, simplified control solutions ensuring simple MVM architecture and that could be thus implemented on nowadays systems or future complex systems. We theoretically derive various solutions and analyze their respective performance on various systems thanks to numerical simulation. We discuss the optimization of their performance and stability issues with respect to classic control solutions. We finally discuss off-line computation and implementation constraints.
Robust statistical reconstruction for charged particle tomography
Schultz, Larry Joe; Klimenko, Alexei Vasilievich; Fraser, Andrew Mcleod; Morris, Christopher; Orum, John Christopher; Borozdin, Konstantin N; Sossong, Michael James; Hengartner, Nicolas W
2013-10-08
Systems and methods for charged particle detection including statistical reconstruction of object volume scattering density profiles from charged particle tomographic data to determine the probability distribution of charged particle scattering using a statistical multiple scattering model and determine a substantially maximum likelihood estimate of object volume scattering density using expectation maximization (ML/EM) algorithm to reconstruct the object volume scattering density. The presence of and/or type of object occupying the volume of interest can be identified from the reconstructed volume scattering density profile. The charged particle tomographic data can be cosmic ray muon tomographic data from a muon tracker for scanning packages, containers, vehicles or cargo. The method can be implemented using a computer program which is executable on a computer.
New method to analyze internal disruptions with tomographic reconstructions
NASA Astrophysics Data System (ADS)
Tanzi, C. P.; de Blank, H. J.
1997-03-01
Sawtooth crashes have been investigated on the Rijnhuizen Tokamak Project (RTP) [N. J. Lopes Cardozo et al., Proceedings of the 14th International Conference on Plasma Physics and Controlled Nuclear Fusion Research, Würzburg, 1992 (International Atomic Energy Agency, Vienna, 1993), Vol. 1, p. 271]. Internal disruptions in tokamak plasmas often exhibit an m=1 poloidal mode structure prior to the collapse which can be clearly identified by means of multicamera soft x-ray diagnostics. In this paper tomographic reconstructions of such m=1 modes are analyzed with a new method, based on magnetohydrodynamic (MHD) invariants computed from the two-dimensional emissivity profiles, which quantifies the amount of profile flattening not only after the crash but also during the precursor oscillations. The results are interpreted by comparing them with two models which simulate the measurements of the m=1 redistribution of soft x-ray emissivity prior to the sawtooth crash. One model is based on the magnetic reconnection model of Kadomtsev. The other involves ideal MHD motion only. In cases where differences in magnetic topology between the two models cannot be seen in the tomograms, the analysis of profile flattening has an advantage. The analysis shows that in RTP the clearly observed m=1 displacement of some sawteeth requires the presence of convective ideal MHD motion, whereas other precursors are consistent with magnetic reconnection of up to 75% of the magnetic flux within the q=1 surface. The possibility of ideal interchange combined with enhanced cross-field transport is not excluded.
2015-05-18
Head computed tomographic scan most commonly found skull fracture (68.9%), subdural hematoma (54.1%), and cerebral contusion (51.4%). Hypertonic saline...were common on presentation. Head computed tomographic scan most commonly found skull fracture (68.9%), subdural hematoma (54.1%), and cerebral con...reported was skull fracture, occurring in 68.9% of patients. The most common type of intracranial hemorrhage was subdural hematoma (54.1%). Multiple
Computer tomographic evaluation of digestive tract non-Hodgkin lymphomas.
Lupescu, Ioana G; Grasu, Mugur; Goldis, Gheorghe; Popa, Gelu; Gheorghe, Cristian; Vasilescu, Catalin; Moicean, Andreea; Herlea, Vlad; Georgescu, Serban A
2007-09-01
Computer Tomographic (CT) study is crucial for defining distribution, characteristics and staging of primary gastrointestinal lymphomas. The presence of multifocal sites, the wall thickening with diffuse infiltration of the affected gastrointestinal (GI) segment in association with regional adenopathies, permit the orientation of the CT diagnosis for primary GI lymphomas. The gold standard for diagnosis remains, in all cases of digestive tract non-Hodgkin lymphomas (NHL), the histological examination, which allows a tissue diagnosis, performed preferably by transmural biopsy.
The auroral 6300 A emission - Observations and modeling
NASA Technical Reports Server (NTRS)
Solomon, Stanley C.; Hays, Paul B.; Abreu, Vincent J.
1988-01-01
A tomographic inversion is used to analyze measurements of the auroral atomic oxygen emission line at 6300 A made by the atmosphere explorer visible airglow experiment. A comparison is made between emission altitude profiles and the results from an electron transport and chemical reaction model. Measurements of the energetic electron flux, neutral composition, ion composition, and electron density are incorporated in the model.
Widmer, W R; Buckwalter, K A; Fessler, J F; Hill, M A; VanSickle, D C; Ivancevich, S
2000-01-01
Radiographic evaluation of navicular syndrome is problematic because of its inconsistent correlation with clinical signs. Scintigraphy often yields false positive and false negative results and diagnostic ultrasound is of limited value. Therefore, we assessed the use of computed tomography and magnetic resonance imaging in a horse with clinical and radiographic signs of navicular syndrome. Cadaver specimens were examined with spiral computed tomographic and high-field magnetic resonance scanners and images were correlated with pathologic findings. Radiographic changes consisted of bony remodeling, which included altered synovial fossae, increased medullary opacity, cyst formation and shape change. These osseous changes were more striking and more numerous on computed tomographic and magnetic resonance images. They were most clearly defined with computed tomography. Many osseous changes seen with computed tomography and magnetic resonance imaging were not radiographically evident. Histologically confirmed soft tissue alterations of the deep digital flexor tendon, impar ligament and marrow were identified with magnetic resonance imaging, but not with conventional radiography. Because of their multiplanar capability and tomographic nature, computed tomography and magnetic resonance imaging surpass conventional radiography for navicular imaging, facilitating earlier, more accurate diagnosis. Current advances in imaging technology should make these imaging modalities available to equine practitioners in the future.
5D-intravital tomography as a novel tool for non-invasive in-vivo analysis of human skin
NASA Astrophysics Data System (ADS)
König, Karsten; Weinigel, Martin; Breunig, Hans G.; Gregory, Axel; Fischer, Peter; Kellner-Höfer, Marcel; Bückle, Rainer; Schwarz, Martin; Riemann, Iris; Stracke, Frank; Huck, Volker; Gorzelanny, Christian; Schneider, Stefan W.
2010-02-01
Some years ago, CE-marked clinical multiphoton systems for 3D imaging of human skin with subcellular resolution have been launched. These tomographs provide optical biopsies with submicron resolution based on two-photon excited autofluorescence (NAD(P)H, flavoproteins, keratin, elastin, melanin, porphyrins) and second harmonic generation by collagen. The 3D tomograph was now transferred into a 5D imaging system by the additional detection of the emission spectrum and the fluorescence lifetime based on spatially and spectrally resolved time-resolved single photon counting. The novel 5D intravital tomograph (5D-IVT) was employed for the early detection of atopic dermatitis and the analysis of treatment effects.
Mair, Grant; von Kummer, Rüdiger; Adami, Alessandro; White, Philip M.; Adams, Matthew E.; Yan, Bernard; Demchuk, Andrew M.; Farrall, Andrew J.; Sellar, Robin J.; Sakka, Eleni; Palmer, Jeb; Perry, David; Lindley, Richard I.; Sandercock, Peter A.G.
2017-01-01
Background and Purpose— Computed tomographic angiography and magnetic resonance angiography are used increasingly to assess arterial patency in patients with ischemic stroke. We determined which baseline angiography features predict response to intravenous thrombolytics in ischemic stroke using randomized controlled trial data. Methods— We analyzed angiograms from the IST-3 (Third International Stroke Trial), an international, multicenter, prospective, randomized controlled trial of intravenous alteplase. Readers, masked to clinical, treatment, and outcome data, assessed prerandomization computed tomographic angiography and magnetic resonance angiography for presence, extent, location, and completeness of obstruction and collaterals. We compared angiography findings to 6-month functional outcome (Oxford Handicap Scale) and tested for interactions with alteplase, using ordinal regression in adjusted analyses. We also meta-analyzed all available angiography data from other randomized controlled trials of intravenous thrombolytics. Results— In IST-3, 300 patients had prerandomization angiography (computed tomographic angiography=271 and magnetic resonance angiography=29). On multivariable analysis, more extensive angiographic obstruction and poor collaterals independently predicted poor outcome (P<0.01). We identified no significant interaction between angiography findings and alteplase effect on Oxford Handicap Scale (P≥0.075) in IST-3. In meta-analysis (5 trials of alteplase or desmoteplase, including IST-3, n=591), there was a significantly increased benefit of thrombolytics on outcome (odds ratio>1 indicates benefit) in patients with (odds ratio, 2.07; 95% confidence interval, 1.18–3.64; P=0.011) versus without (odds ratio, 0.88; 95% confidence interval, 0.58–1.35; P=0.566) arterial obstruction (P for interaction 0.017). Conclusions— Intravenous thrombolytics provide benefit to stroke patients with computed tomographic angiography or magnetic resonance angiography evidence of arterial obstruction, but the sample was underpowered to demonstrate significant treatment benefit or harm among patients with apparently patent arteries. Clinical Trial Registration— URL: http://www.isrctn.com. Unique identifier: ISRCTN25765518. PMID:28008093
Mair, Grant; von Kummer, Rüdiger; Adami, Alessandro; White, Philip M; Adams, Matthew E; Yan, Bernard; Demchuk, Andrew M; Farrall, Andrew J; Sellar, Robin J; Sakka, Eleni; Palmer, Jeb; Perry, David; Lindley, Richard I; Sandercock, Peter A G; Wardlaw, Joanna M
2017-02-01
Computed tomographic angiography and magnetic resonance angiography are used increasingly to assess arterial patency in patients with ischemic stroke. We determined which baseline angiography features predict response to intravenous thrombolytics in ischemic stroke using randomized controlled trial data. We analyzed angiograms from the IST-3 (Third International Stroke Trial), an international, multicenter, prospective, randomized controlled trial of intravenous alteplase. Readers, masked to clinical, treatment, and outcome data, assessed prerandomization computed tomographic angiography and magnetic resonance angiography for presence, extent, location, and completeness of obstruction and collaterals. We compared angiography findings to 6-month functional outcome (Oxford Handicap Scale) and tested for interactions with alteplase, using ordinal regression in adjusted analyses. We also meta-analyzed all available angiography data from other randomized controlled trials of intravenous thrombolytics. In IST-3, 300 patients had prerandomization angiography (computed tomographic angiography=271 and magnetic resonance angiography=29). On multivariable analysis, more extensive angiographic obstruction and poor collaterals independently predicted poor outcome (P<0.01). We identified no significant interaction between angiography findings and alteplase effect on Oxford Handicap Scale (P≥0.075) in IST-3. In meta-analysis (5 trials of alteplase or desmoteplase, including IST-3, n=591), there was a significantly increased benefit of thrombolytics on outcome (odds ratio>1 indicates benefit) in patients with (odds ratio, 2.07; 95% confidence interval, 1.18-3.64; P=0.011) versus without (odds ratio, 0.88; 95% confidence interval, 0.58-1.35; P=0.566) arterial obstruction (P for interaction 0.017). Intravenous thrombolytics provide benefit to stroke patients with computed tomographic angiography or magnetic resonance angiography evidence of arterial obstruction, but the sample was underpowered to demonstrate significant treatment benefit or harm among patients with apparently patent arteries. URL: http://www.isrctn.com. Unique identifier: ISRCTN25765518. © 2016 The Authors.
Banzato, T; Selleri, P; Veladiano, I A; Zotti, A
2013-12-01
Contrast-enhanced computed tomographic studies of the coelomic cavity in four green iguanas, four black and white tegus and four bearded dragons were performed using a conventional CT scanner. Anatomical reference cross sections were obtained from four green iguana, four black and white tegu and six bearded dragon cadavers; the specimens were stored in a -20°C freezer for 24 h then sliced into 5-mm intervals. The frozen sections were cleaned with water and photographed on both sides. The individual anatomical structures were identified by means of the available literature; these were labelled first on the anatomical images and then matched to the corresponding computed tomography images. The results provide an atlas of the normal cross-sectional and computed tomographic anatomy of the coelomic cavity in the green iguana, the black and white tegu and the bearded dragon, which is useful in the interpretation of any imaging modality. © 2013 Blackwell Verlag GmbH.
Ketoff, Serge; Khonsari, Roman Hossein; Schouman, Thomas; Bertolus, Chloé
2014-11-01
Handling 3-dimensional reconstructions of computed tomographic scans on portable devices is problematic because of the size of the Digital Imaging and Communications in Medicine (DICOM) stacks. The authors provide a user-friendly method allowing the production, transfer, and sharing of good-quality 3-dimensional reconstructions on smartphones and tablets. Copyright © 2014 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
1987-01-01
BLOOD FLOW CHANGE Steven E. Petersen, Peter T. Fox, Michael I. Posner, Marcus Raichle McDonnell Center for Studies of Higher Brain Function...Single Words Using Positron Emission Tomographic Measurements of Cerebral Blood Flow Change *= ’I PERSONAL AUTHOR(S) * Petersen, Steven E. 13a. TYPE OF...CHANGE Steven E. Petersen, Peter T. Fox, Michael I. Posner, Marcus E. Raichle INTRODUCTION Language is an essential characteristic of the human
Caliyurt, Okan; Vardar, Erdal; Tuglu, Cengiz
2004-01-01
We report a case of Cotard's syndrome associated with psychotic symptoms. A 27-year-old man was admitted to hospital with the diagnosis of schizophreniform disorder. His presenting symptoms, which had started 1 month before hospital admission, were somatic delusions of gastrointestinal and cardiovascular malfunction and the absence of a stomach, which resulted in a decrease in weight from 75 kg to 63 kg in 1 month. Cranial computed tomographic images showed dilatation of the lateral and third ventricles, whereas magnetic resonance imaging revealed central atrophy and lateral ventricle dilatation. Single- photon emission computed tomography demonstrated left temporal, left frontal and left parietal hypoperfusion. The patient did not respond to antipsychotic therapies, but he was successfully treated with electroconvulsive therapy. This report emphasizes that Cotard's syndrome may be accompanied by lesions of the left hemisphere and that electroconvulsive therapy could be the first-line therapy in such patients with psychotic disorder. PMID:15069468
Akoglu, Haldun; Akoglu, Ebru Unal; Evman, Serdar; Akoglu, Tayfun; Denizbasi, Arzu; Guneysel, Ozlem; Onur, Ozge; Onur, Ender
2012-10-01
Small pneumothoraces (PXs), which are not initially recognized with a chest x-ray film and diagnosed by a thoracic computed tomography (CT), are described as occult PX (OCPX). The objective of this study was to evaluate cervival spine (C-spine) and abdominal CT (ACT) for diagnosing OCPX and overt PX (OVPX). All patients with blunt trauma who presented consecutively to the emergency department during a 26-months period were included. Among all the chest CTs (CCTs) (6,155 patients) conducted during that period, 254 scans were confirmed to have a true PX. The findings in their C-spine CT and ACT were compared with the findings in CCTs. Among these patients, 254 had a diagnosis of PX confirmed with CCT. OCPXs were identified on the chest computed tomographic scan of 128 patients (70.3%), whereas OVPXs were evident in 54 patients (29.7%). Computed tomographic imaging of the C-spine was performed in 74% of patients with OCPX and 66.7% of patients with OVPX trauma. Only 45 (35.2%) cases of OCPX and 42 (77.8%) cases of OVPX were detected by C-spine CT. ACT was performed in almost all patients, and 121 (95.3%) of 127 of these correctly identified an existing OCPX. Sensitivity of C-spine CT and ACT was 35.1% and 96.5%, respectively; specificity was 100% and 100%, respectively. Almost all OCPXs, regardless of intrathoracic location, could be detected by ACT or by combining C-spine and abdominal computed tomographic screening for patients. If the junction of the first and second vertebra is used as the caudad extent, C-spine CT does not have sufficient power to diagnose more than a third of the cases. Diagnostic study, level III.
Cerebral blood flow tomography with xenon-133
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lassen, N.A.
1985-10-01
Cerebral blood flow (CBF) can be measured tomographically by inhalation of Xenon-/sup 133/. The calculation is based on taking a sequence of tomograms during the wash-in and wash-out phase of the tracer. Due to the dynamic nature of the process, a highly sensitive and fast moving single photon emission computed tomograph (SPECT) is required. Two brain-dedicated SPECT systems designed for this purpose are mentioned, and the method is described with special reference to the limitations inherent in the soft energy of the 133Xe primary photons. CBF tomography can be used for a multitude of clinical and investigative purposes. This articlemore » discusses in particular its use for the selection of patients with carotid occlusion for extracranial/intracranial bypass surgery, for detection of severe arterial spasm after aneurysm bleeding, and for detection of low flow areas during severe migraine attacks. The use of other tracers for CBF tomography using SPECT is summarized with emphasis on the /sup 99m/Tc chelates that freely pass the intact blood-brain barrier. The highly sensitive brain-dedicated SPECT systems described are a prerequisite for achieving high resolution tomograms with such tracers.« less
Agulleiro, Jose-Ignacio; Fernandez, Jose-Jesus
2015-01-01
Cache blocking is a technique widely used in scientific computing to minimize the exchange of information with main memory by reusing the data kept in cache memory. In tomographic reconstruction on standard computers using vector instructions, cache blocking turns out to be central to optimize performance. To this end, sinograms of the tilt-series and slices of the volumes to be reconstructed have to be divided into small blocks that fit into the different levels of cache memory. The code is then reorganized so as to operate with a block as much as possible before proceeding with another one. This data article is related to the research article titled Tomo3D 2.0 – Exploitation of Advanced Vector eXtensions (AVX) for 3D reconstruction (Agulleiro and Fernandez, 2015) [1]. Here we present data of a thorough study of the performance of tomographic reconstruction by varying cache block sizes, which allows derivation of expressions for their automatic quasi-optimal tuning. PMID:26217710
Agulleiro, Jose-Ignacio; Fernandez, Jose-Jesus
2015-06-01
Cache blocking is a technique widely used in scientific computing to minimize the exchange of information with main memory by reusing the data kept in cache memory. In tomographic reconstruction on standard computers using vector instructions, cache blocking turns out to be central to optimize performance. To this end, sinograms of the tilt-series and slices of the volumes to be reconstructed have to be divided into small blocks that fit into the different levels of cache memory. The code is then reorganized so as to operate with a block as much as possible before proceeding with another one. This data article is related to the research article titled Tomo3D 2.0 - Exploitation of Advanced Vector eXtensions (AVX) for 3D reconstruction (Agulleiro and Fernandez, 2015) [1]. Here we present data of a thorough study of the performance of tomographic reconstruction by varying cache block sizes, which allows derivation of expressions for their automatic quasi-optimal tuning.
Prabhakar, Attiguppe R; Yavagal, Chandrashekar; Dixit, Kratika; Naik, Saraswathi V
2016-01-01
Primary root canals are considered to be most challenging due to their complex anatomy. "Wave one" and "one shape" are single-file systems with reciprocating and rotary motion respectively. The aim of this study was to evaluate and compare dentin thickness, centering ability, canal transportation, and instrumentation time of wave one and one shape files in primary root canals using a cone beam computed tomographic (CBCT) analysis. This is an experimental, in vitro study comparing the two groups. A total of 24 extracted human primary teeth with minimum 7 mm root length were included in the study. Cone beam computed tomographic images were taken before and after the instrumentation for each group. Dentin thickness, centering ability, canal transportation, and instrumentation times were evaluated for each group. A significant difference was found in instrumentation time and canal transportation measures between the two groups. Wave one showed less canal transportation as compared with one shape, and the mean instrumentation time of wave one was significantly less than one shape. Reciprocating single-file systems was found to be faster with much less procedural errors and can hence be recommended for shaping the root canals of primary teeth. How to cite this article: Prabhakar AR, Yavagal C, Dixit K, Naik SV. Reciprocating vs Rotary Instrumentation in Pediatric Endodontics: Cone Beam Computed Tomographic Analysis of Deciduous Root Canals using Two Single-File Systems. Int J Clin Pediatr Dent 2016;9(1):45-49.
Washko, George R; Criner, Gerald J; Mohsenifar, Zab; Sciurba, Frank C; Sharafkhaneh, Amir; Make, Barry J; Hoffman, Eric A; Reilly, John J
2008-06-01
Computed tomographic based indices of emphysematous lung destruction may highlight differences in disease pathogenesis and further enable the classification of subjects with Chronic Obstructive Pulmonary Disease. While there are multiple techniques that can be utilized for such radiographic analysis, there is very little published information comparing the performance of these methods in a clinical case series. Our objective was to examine several quantitative and semi-quantitative methods for the assessment of the burden of emphysema apparent on computed tomographic scans and compare their ability to predict lung mechanics and function. Automated densitometric analysis was performed on 1094 computed tomographic scans collected upon enrollment into the National Emphysema Treatment Trial. Trained radiologists performed an additional visual grading of emphysema on high resolution CT scans. Full pulmonary function test results were available for correlation, with a subset of subjects having additional measurements of lung static recoil. There was a wide range of emphysematous lung destruction apparent on the CT scans and univariate correlations to measures of lung function were of modest strength. No single method of CT scan analysis clearly outperformed the rest of the group. Quantification of the burden of emphysematous lung destruction apparent on CT scan is a weak predictor of lung function and mechanics in severe COPD with no uniformly superior method found to perform this analysis. The CT based quantification of emphysema may augment pulmonary function testing in the characterization of COPD by providing complementary phenotypic information.
Concurrent Ultrasonic Tomography and Acoustic Emission in Solid Materials
NASA Astrophysics Data System (ADS)
Chow, Thomas M.
A series of experiments were performed to detect stress induced changes in the elastic properties of various solid materials. A technique was developed where these changes were monitored concurrently by two methods, ultrasonic tomography and acoustic emission monitoring. This thesis discusses some experiments in which acoustic emission (AE) and ultrasonic tomography were performed on various samples of solid materials including rocks, concrete, metals, and fibre reinforced composites. Three separate techniques were used to induce stress in these samples. Disk shaped samples were subject to stress via diametral loading using an indirect tensile test geometry. Cylindrical samples of rocks and concrete were subject to hydraulic fracture tests, and rectangular samples of fibre reinforced composite were subject to direct tensile loading. The majority of the samples were elastically anisotropic. Full waveform acoustic emission and tomographic data were collected while these samples were under load to give information concerning changes in the structure of the material as it was undergoing stress change and/or failure. Analysis of this data indicates that AE and tomographic techniques mutually compliment each other to give a view of the stress induced elastic changes in the tested samples.
Parallel Computing for the Computed-Tomography Imaging Spectrometer
NASA Technical Reports Server (NTRS)
Lee, Seungwon
2008-01-01
This software computes the tomographic reconstruction of spatial-spectral data from raw detector images of the Computed-Tomography Imaging Spectrometer (CTIS), which enables transient-level, multi-spectral imaging by capturing spatial and spectral information in a single snapshot.
NASA Astrophysics Data System (ADS)
Dymond, K.; Nicholas, A. C.; Budzien, S. A.; Stephan, A. W.; Coker, C.; Hei, M. A.; Groves, K. M.
2015-12-01
The Special Sensor Ultraviolet Limb Imager (SSULI) instruments are ultraviolet limb scanning sensors flying on the Defense Meteorological Satellite Program (DMSP) satellites. The SSULIs observe the 80-170 nanometer wavelength range covering emissions at 91 and 136 nm, which are produced by radiative recombination of the ionosphere. We invert these emissions tomographically using newly developed algorithms that include optical depth effects due to pure absorption and resonant scattering. We present the details of our approach including how the optimal altitude and along-track sampling were determined and the newly developed approach we are using for regularizing the SSULI tomographic inversions. Finally, we conclude with validations of the SSULI inversions against ALTAIR incoherent scatter radar measurements and demonstrate excellent agreement between the measurements.
Min, James K; Shaw, Leslee J; Berman, Daniel S; Gilmore, Amanda; Kang, Ning
2008-09-15
Multidetector coronary computed tomographic angiography (CCTA) demonstrates high accuracy for the detection and exclusion of coronary artery disease (CAD) and predicts adverse prognosis. To date, opportunity costs relating the clinical and economic outcomes of CCTA compared with other methods of diagnosing CAD, such as myocardial perfusion single-photon emission computed tomography (SPECT), remain unknown. An observational, multicenter, patient-level analysis of patients without known CAD who underwent CCTA or SPECT was performed. Patients who underwent CCTA (n = 1,938) were matched to those who underwent SPECT (n = 7,752) on 8 demographic and clinical characteristics and 2 summary measures of cardiac medications and co-morbidities and were evaluated for 9-month expenditures and clinical outcomes. Adjusted total health care and CAD expenditures were 27% (p <0.001) and 33% (p <0.001) lower, respectively, for patients who underwent CCTA compared with those who underwent SPECT, by an average of $467 (95% confidence interval $99 to $984) for CAD expenditures per patient. Despite lower total health care expenditures for CCTA, no differences were observed for rates of adverse cardiovascular events, including CAD hospitalizations (4.2% vs 4.1%, p = NS), CAD outpatient visits (17.4% vs 13.3%, p = NS), myocardial infarction (0.4% vs 0.6%, p = NS), and new-onset angina (3.0% vs 3.5%, p = NS). Patients without known CAD who underwent CCTA, compared with matched patients who underwent SPECT, incurred lower overall health care and CAD expenditures while experiencing similarly low rates of CAD hospitalization, outpatient visits, myocardial infarction, and angina. In conclusion, these data suggest that CCTA may be a cost-efficient alternative to SPECT for the initial coronary evaluation of patients without known CAD.
NASA Astrophysics Data System (ADS)
Rathore, Kavita; Bhattacharjee, Sudeep; Munshi, Prabhat
2017-06-01
A tomographic method based on the Fourier transform is used for characterizing a microwave plasma in a multicusp (MC), in order to obtain 2D distribution of plasma emissions, plasma (electron) density (Ne) and temperature (Te). The microwave plasma in the MC is characterized as a function of microwave power, gas pressure, and axial distance. The experimentally obtained 2D emission profiles show that the plasma emissions are generated in a circular ring shape. There are usually two bright rings, one at the plasma core and another near the boundary. The experimental results are validated using a numerical code that solves Maxwell's equations inside a waveguide filled with a plasma in a magnetic field, with collisions included. It is inferred that the dark and bright circular ring patterns are a result of superposition of Bessel modes (TE11 and TE21) of the wave electric field inside the plasma filled MC, which are in reasonable agreement with the plasma emission profiles. The tomographically obtained Ne and Te profiles indicate higher densities in the plasma core (˜1010 cm-3) and enhanced electron temperature in the ECR region (˜13 eV), which are in agreement with earlier results using a Langmuir probe and optical emission spectroscopy (OES) diagnostics.
Tomographic diagnostics of nonthermal plasmas
NASA Astrophysics Data System (ADS)
Denisova, Natalia
2009-10-01
In the previous work [1], we discussed a ``technology'' of tomographic method and relations between the tomographic diagnostics in thermal (equilibrium) and nonthermal (nonequilibrium) plasma sources. The conclusion has been made that tomographic reconstruction in thermal plasma sources is the standard procedure at present, which can provide much useful information on the plasma structure and its evolution in time, while the tomographic reconstruction of nonthermal plasma has a great potential at making a contribution to understanding the fundamental problem of substance behavior in strongly nonequilibrium conditions. Using medical terminology, one could say, that tomographic diagnostics of the equilibrium plasma sources studies their ``anatomic'' structure, while reconstruction of the nonequilibrium plasma is similar to the ``physiological'' examination: it is directed to study the physical mechanisms and processes. The present work is focused on nonthermal plasma research. The tomographic diagnostics is directed to study spatial structures formed in the gas discharge plasmas under the influence of electrical and gravitational fields. The ways of plasma ``self-organization'' in changing and extreme conditions are analyzed. The analysis has been made using some examples from our practical tomographic diagnostics of nonthermal plasma sources, such as low-pressure capacitive and inductive discharges. [0pt] [1] Denisova N. Plasma diagnostics using computed tomography method // IEEE Trans. Plasma Sci. 2009 37 4 502.
Analysis of computer images in the presence of metals
NASA Astrophysics Data System (ADS)
Buzmakov, Alexey; Ingacheva, Anastasia; Prun, Victor; Nikolaev, Dmitry; Chukalina, Marina; Ferrero, Claudio; Asadchikov, Victor
2018-04-01
Artifacts caused by intensely absorbing inclusions are encountered in computed tomography via polychromatic scanning and may obscure or simulate pathologies in medical applications. To improve the quality of reconstruction if high-Z inclusions in presence, previously we proposed and tested with synthetic data an iterative technique with soft penalty mimicking linear inequalities on the photon-starved rays. This note reports a test at the tomographic laboratory set-up at the Institute of Crystallography FSRC "Crystallography and Photonics" RAS in which tomographic scans were successfully made of temporary tooth without inclusion and with Pb inclusion.
Nose and Nasal Planum Neoplasia, Reconstruction.
Worley, Deanna R
2016-07-01
Most intranasal lesions are best treated with radiation therapy. Computed tomographic imaging with intravenous contrast is critical for treatment planning. Computed tomographic images of the nose will best assess the integrity of the cribriform plate for central nervous system invasion by a nasal tumor. Because of an owner's emotional response to an altered appearance of their dog's face, discussions need to include the entire family before proceeding with nasal planectomy or radical planectomy. With careful case selection, nasal planectomy and radical planectomy surgeries can be locally curative. Copyright © 2016 Elsevier Inc. All rights reserved.
Trace: a high-throughput tomographic reconstruction engine for large-scale datasets
Bicer, Tekin; Gursoy, Doga; Andrade, Vincent De; ...
2017-01-28
Here, synchrotron light source and detector technologies enable scientists to perform advanced experiments. These scientific instruments and experiments produce data at such scale and complexity that large-scale computation is required to unleash their full power. One of the widely used data acquisition technique at light sources is Computed Tomography, which can generate tens of GB/s depending on x-ray range. A large-scale tomographic dataset, such as mouse brain, may require hours of computation time with a medium size workstation. In this paper, we present Trace, a data-intensive computing middleware we developed for implementation and parallelization of iterative tomographic reconstruction algorithms. Tracemore » provides fine-grained reconstruction of tomography datasets using both (thread level) shared memory and (process level) distributed memory parallelization. Trace utilizes a special data structure called replicated reconstruction object to maximize application performance. We also present the optimizations we have done on the replicated reconstruction objects and evaluate them using a shale and a mouse brain sinogram. Our experimental evaluations show that the applied optimizations and parallelization techniques can provide 158x speedup (using 32 compute nodes) over single core configuration, which decreases the reconstruction time of a sinogram (with 4501 projections and 22400 detector resolution) from 12.5 hours to less than 5 minutes per iteration.« less
Trace: a high-throughput tomographic reconstruction engine for large-scale datasets
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bicer, Tekin; Gursoy, Doga; Andrade, Vincent De
Here, synchrotron light source and detector technologies enable scientists to perform advanced experiments. These scientific instruments and experiments produce data at such scale and complexity that large-scale computation is required to unleash their full power. One of the widely used data acquisition technique at light sources is Computed Tomography, which can generate tens of GB/s depending on x-ray range. A large-scale tomographic dataset, such as mouse brain, may require hours of computation time with a medium size workstation. In this paper, we present Trace, a data-intensive computing middleware we developed for implementation and parallelization of iterative tomographic reconstruction algorithms. Tracemore » provides fine-grained reconstruction of tomography datasets using both (thread level) shared memory and (process level) distributed memory parallelization. Trace utilizes a special data structure called replicated reconstruction object to maximize application performance. We also present the optimizations we have done on the replicated reconstruction objects and evaluate them using a shale and a mouse brain sinogram. Our experimental evaluations show that the applied optimizations and parallelization techniques can provide 158x speedup (using 32 compute nodes) over single core configuration, which decreases the reconstruction time of a sinogram (with 4501 projections and 22400 detector resolution) from 12.5 hours to less than 5 minutes per iteration.« less
An efficient and accurate approach to MTE-MART for time-resolved tomographic PIV
NASA Astrophysics Data System (ADS)
Lynch, K. P.; Scarano, F.
2015-03-01
The motion-tracking-enhanced MART (MTE-MART; Novara et al. in Meas Sci Technol 21:035401, 2010) has demonstrated the potential to increase the accuracy of tomographic PIV by the combined use of a short sequence of non-simultaneous recordings. A clear bottleneck of the MTE-MART technique has been its computational cost. For large datasets comprising time-resolved sequences, MTE-MART becomes unaffordable and has been barely applied even for the analysis of densely seeded tomographic PIV datasets. A novel implementation is proposed for tomographic PIV image sequences, which strongly reduces the computational burden of MTE-MART, possibly below that of regular MART. The method is a sequential algorithm that produces a time-marching estimation of the object intensity field based on an enhanced guess, which is built upon the object reconstructed at the previous time instant. As the method becomes effective after a number of snapshots (typically 5-10), the sequential MTE-MART (SMTE) is most suited for time-resolved sequences. The computational cost reduction due to SMTE simply stems from the fewer MART iterations required for each time instant. Moreover, the method yields superior reconstruction quality and higher velocity field measurement precision when compared with both MART and MTE-MART. The working principle is assessed in terms of computational effort, reconstruction quality and velocity field accuracy with both synthetic time-resolved tomographic images of a turbulent boundary layer and two experimental databases documented in the literature. The first is the time-resolved data of flow past an airfoil trailing edge used in the study of Novara and Scarano (Exp Fluids 52:1027-1041, 2012); the second is a swirling jet in a water flow. In both cases, the effective elimination of ghost particles is demonstrated in number and intensity within a short temporal transient of 5-10 frames, depending on the seeding density. The increased value of the velocity space-time correlation coefficient demonstrates the increased velocity field accuracy of SMTE compared with MART.
Development of an oximeter for neurology
NASA Astrophysics Data System (ADS)
Aleinik, A.; Serikbekova, Z.; Zhukova, N.; Zhukova, I.; Nikitina, M.
2016-06-01
Cerebral desaturation can occur during surgery manipulation, whereas other parameters vary insignificantly. Prolonged intervals of cerebral anoxia can cause serious damage to the nervous system. Commonly used method for measurement of cerebral blood flow uses invasive catheters. Other techniques include single photon emission computed tomography (SPECT), positron emission tomography (PET), magnetic resonance imaging (MRI). Tomographic methods frequently use isotope administration, that may result in anaphylactic reactions to contrast media and associated nerve diseases. Moreover, the high cost and the need for continuous monitoring make it difficult to apply these techniques in clinical practice. Cerebral oximetry is a method for measuring oxygen saturation using infrared spectrometry. Moreover reflection pulse oximetry can detect sudden changes in sympathetic tone. For this purpose the reflectance pulse oximeter for use in neurology is developed. Reflectance oximeter has a definite advantage as it can be used to measure oxygen saturation in any part of the body. Preliminary results indicate that the device has a good resolution and high reliability. Modern applied schematics have improved device characteristics compared with existing ones.
NASA Astrophysics Data System (ADS)
Thorek, Daniel L. J.; Ulmert, David; Diop, Ndeye-Fatou M.; Lupu, Mihaela E.; Doran, Michael G.; Huang, Ruimin; Abou, Diane S.; Larson, Steven M.; Grimm, Jan
2014-01-01
The invasion status of tumour-draining lymph nodes (LNs) is a critical indicator of cancer stage and is important for treatment planning. Clinicians currently use planar scintigraphy and single-photon emission computed tomography (SPECT) with 99mTc-radiocolloid to guide biopsy and resection of LNs. However, emerging multimodality approaches such as positron emission tomography combined with magnetic resonance imaging (PET/MRI) detect sites of disease with higher sensitivity and accuracy. Here we present a multimodal nanoparticle, 89Zr-ferumoxytol, for the enhanced detection of LNs with PET/MRI. For genuine translational potential, we leverage a clinical iron oxide formulation, altered with minimal modification for radiolabelling. Axillary drainage in naive mice and from healthy and tumour-bearing prostates was investigated. We demonstrate that 89Zr-ferumoxytol can be used for high-resolution tomographic studies of lymphatic drainage in preclinical disease models. This nanoparticle platform has significant translational potential to improve preoperative planning for nodal resection and tumour staging.
Functional-Lesion Investigation of Developmental Stuttering with Positron Emission Tomography.
ERIC Educational Resources Information Center
Ingham, Roger J.; And Others
1996-01-01
Analysis of use of positron emission tomographic measurements of resting-state regional cerebral blood flow in 29 men, 10 of whom stuttered, did not support the idea that developmental stuttering is associated with abnormalities of blood flow at rest. Findings did suggest an essentially normal functional brain terrain with a small number of minor…
Rapid tomographic reconstruction based on machine learning for time-resolved combustion diagnostics
NASA Astrophysics Data System (ADS)
Yu, Tao; Cai, Weiwei; Liu, Yingzheng
2018-04-01
Optical tomography has attracted surged research efforts recently due to the progress in both the imaging concepts and the sensor and laser technologies. The high spatial and temporal resolutions achievable by these methods provide unprecedented opportunity for diagnosis of complicated turbulent combustion. However, due to the high data throughput and the inefficiency of the prevailing iterative methods, the tomographic reconstructions which are typically conducted off-line are computationally formidable. In this work, we propose an efficient inversion method based on a machine learning algorithm, which can extract useful information from the previous reconstructions and build efficient neural networks to serve as a surrogate model to rapidly predict the reconstructions. Extreme learning machine is cited here as an example for demonstrative purpose simply due to its ease of implementation, fast learning speed, and good generalization performance. Extensive numerical studies were performed, and the results show that the new method can dramatically reduce the computational time compared with the classical iterative methods. This technique is expected to be an alternative to existing methods when sufficient training data are available. Although this work is discussed under the context of tomographic absorption spectroscopy, we expect it to be useful also to other high speed tomographic modalities such as volumetric laser-induced fluorescence and tomographic laser-induced incandescence which have been demonstrated for combustion diagnostics.
Rapid tomographic reconstruction based on machine learning for time-resolved combustion diagnostics.
Yu, Tao; Cai, Weiwei; Liu, Yingzheng
2018-04-01
Optical tomography has attracted surged research efforts recently due to the progress in both the imaging concepts and the sensor and laser technologies. The high spatial and temporal resolutions achievable by these methods provide unprecedented opportunity for diagnosis of complicated turbulent combustion. However, due to the high data throughput and the inefficiency of the prevailing iterative methods, the tomographic reconstructions which are typically conducted off-line are computationally formidable. In this work, we propose an efficient inversion method based on a machine learning algorithm, which can extract useful information from the previous reconstructions and build efficient neural networks to serve as a surrogate model to rapidly predict the reconstructions. Extreme learning machine is cited here as an example for demonstrative purpose simply due to its ease of implementation, fast learning speed, and good generalization performance. Extensive numerical studies were performed, and the results show that the new method can dramatically reduce the computational time compared with the classical iterative methods. This technique is expected to be an alternative to existing methods when sufficient training data are available. Although this work is discussed under the context of tomographic absorption spectroscopy, we expect it to be useful also to other high speed tomographic modalities such as volumetric laser-induced fluorescence and tomographic laser-induced incandescence which have been demonstrated for combustion diagnostics.
Estimating crustal heterogeneity from double-difference tomography
Got, J.-L.; Monteiller, V.; Virieux, J.; Okubo, P.
2006-01-01
Seismic velocity parameters in limited, but heterogeneous volumes can be inferred using a double-difference tomographic algorithm, but to obtain meaningful results accuracy must be maintained at every step of the computation. MONTEILLER et al. (2005) have devised a double-difference tomographic algorithm that takes full advantage of the accuracy of cross-spectral time-delays of large correlated event sets. This algorithm performs an accurate computation of theoretical travel-time delays in heterogeneous media and applies a suitable inversion scheme based on optimization theory. When applied to Kilauea Volcano, in Hawaii, the double-difference tomography approach shows significant and coherent changes to the velocity model in the well-resolved volumes beneath the Kilauea caldera and the upper east rift. In this paper, we first compare the results obtained using MONTEILLER et al.'s algorithm with those obtained using the classic travel-time tomographic approach. Then, we evaluated the effect of using data series of different accuracies, such as handpicked arrival-time differences ("picking differences"), on the results produced by double-difference tomographic algorithms. We show that picking differences have a non-Gaussian probability density function (pdf). Using a hyperbolic secant pdf instead of a Gaussian pdf allows improvement of the double-difference tomographic result when using picking difference data. We completed our study by investigating the use of spatially discontinuous time-delay data. ?? Birkha??user Verlag, Basel, 2006.
Interlaced X-ray diffraction computed tomography
Vamvakeros, Antonios; Jacques, Simon D. M.; Di Michiel, Marco; Senecal, Pierre; Middelkoop, Vesna; Cernik, Robert J.; Beale, Andrew M.
2016-01-01
An X-ray diffraction computed tomography data-collection strategy that allows, post experiment, a choice between temporal and spatial resolution is reported. This strategy enables time-resolved studies on comparatively short timescales, or alternatively allows for improved spatial resolution if the system under study, or components within it, appear to be unchanging. The application of the method for studying an Mn–Na–W/SiO2 fixed-bed reactor in situ is demonstrated. Additionally, the opportunities to improve the data-collection strategy further, enabling post-collection tuning between statistical, temporal and spatial resolutions, are discussed. In principle, the interlaced scanning approach can also be applied to other pencil-beam tomographic techniques, like X-ray fluorescence computed tomography, X-ray absorption fine structure computed tomography, pair distribution function computed tomography and tomographic scanning transmission X-ray microscopy. PMID:27047305
TomoEED: Fast Edge-Enhancing Denoising of Tomographic Volumes.
Moreno, J J; Martínez-Sánchez, A; Martínez, J A; Garzón, E M; Fernández, J J
2018-05-29
TomoEED is an optimized software tool for fast feature-preserving noise filtering of large 3D tomographic volumes on CPUs and GPUs. The tool is based on the anisotropic nonlinear diffusion method. It has been developed with special emphasis in the reduction of the computational demands by using different strategies, from the algorithmic to the high performance computing perspectives. TomoEED manages to filter large volumes in a matter of minutes in standard computers. TomoEED has been developed in C. It is available for Linux platforms at http://www.cnb.csic.es/%7ejjfernandez/tomoeed. gmartin@ual.es, JJ.Fernandez@csic.es. Supplementary data are available at Bioinformatics online.
Cho, Iksung; Al'Aref, Subhi J; Berger, Adam; Ó Hartaigh, Bríain; Gransar, Heidi; Valenti, Valentina; Lin, Fay Y; Achenbach, Stephan; Berman, Daniel S; Budoff, Matthew J; Callister, Tracy Q; Al-Mallah, Mouaz H; Cademartiri, Filippo; Chinnaiyan, Kavitha; Chow, Benjamin J W; DeLago, Augustin; Villines, Todd C; Hadamitzky, Martin; Hausleiter, Joerg; Leipsic, Jonathon; Shaw, Leslee J; Kaufmann, Philipp A; Feuchtner, Gudrun; Kim, Yong-Jin; Maffei, Erica; Raff, Gilbert; Pontone, Gianluca; Andreini, Daniele; Marques, Hugo; Rubinshtein, Ronen; Chang, Hyuk-Jae; Min, James K
2018-03-14
The long-term prognostic benefit of coronary computed tomographic angiography (CCTA) findings of coronary artery disease (CAD) in asymptomatic populations is unknown. From the prospective multicentre international CONFIRM long-term study, we evaluated asymptomatic subjects without known CAD who underwent both coronary artery calcium scoring (CACS) and CCTA (n = 1226). Coronary computed tomographic angiography findings included the severity of coronary artery stenosis, plaque composition, and coronary segment location. Using the C-statistic and likelihood ratio tests, we evaluated the incremental prognostic utility of CCTA findings over a base model that included a panel of traditional risk factors (RFs) as well as CACS to predict long-term all-cause mortality. During a mean follow-up of 5.9 ± 1.2 years, 78 deaths occurred. Compared with the traditional RF alone (C-statistic 0.64), CCTA findings including coronary stenosis severity, plaque composition, and coronary segment location demonstrated improved incremental prognostic utility beyond traditional RF alone (C-statistics range 0.71-0.73, all P < 0.05; incremental χ2 range 20.7-25.5, all P < 0.001). However, no added prognostic benefit was offered by CCTA findings when added to a base model containing both traditional RF and CACS (C-statistics P > 0.05, for all). Coronary computed tomographic angiography improved prognostication of 6-year all-cause mortality beyond a set of conventional RF alone, although, no further incremental value was offered by CCTA when CCTA findings were added to a model incorporating RF and CACS.
Huang, Chih-Hao; Brunsvold, Michael A
2006-01-01
Maxillary sinusitis may develop from the extension of periodontal disease. In this case, reconstructed three-dimensional images from multidetector spiral computed tomographs were helpful in evaluating periodontal bony defects and their relationship with the maxillary sinus. A 42-year-old woman in good general health presented with a chronic deep periodontal pocket on the palatal and interproximal aspects of tooth #14. Probing depths of the tooth ranged from 2 to 9 mm, and it exhibited a Class 1 mobility. Radiographs revealed a close relationship between the root apex and the maxillary sinus. The patient's periodontal diagnosis was localized severe chronic periodontitis. Treatment of the tooth consisted of cause-related therapy, surgical exploration, and bone grafting. A very deep circumferential bony defect at the palatal root of tooth #14 was noted during surgery. After the operation, the wound healed without incidence, but 10 days later, a maxillary sinusitis and periapical abscess developed. To control the infection, an evaluation of sinus and alveolus using computed tomographs was performed, systemic antibiotics were prescribed, and endodontic treatment was initiated. Two weeks after surgical treatment, the infection was relieved with the help of antibiotics and endodontic treatment. Bilateral bony communications between the maxillary sinus and periodontal bony defect of maxillary first molars were shown on three-dimensional computed tomographs. The digitally reconstructed images added valuable information for evaluating the periodontal defects. Three-dimensional images from spiral computed tomographs (CT) aided in evaluating and treating the close relationship between maxillary sinus disease and adjacent periodontal defects.
Prabhakar, Attiguppe R; Yavagal, Chandrashekar; Naik, Saraswathi V
2016-01-01
ABSTRACT Background: Primary root canals are considered to be most challenging due to their complex anatomy. "Wave one" and "one shape" are single-file systems with reciprocating and rotary motion respectively. The aim of this study was to evaluate and compare dentin thickness, centering ability, canal transportation, and instrumentation time of wave one and one shape files in primary root canals using a cone beam computed tomographic (CBCT) analysis. Study design: This is an experimental, in vitro study comparing the two groups. Materials and methods: A total of 24 extracted human primary teeth with minimum 7 mm root length were included in the study. Cone beam computed tomographic images were taken before and after the instrumentation for each group. Dentin thickness, centering ability, canal transportation, and instrumentation times were evaluated for each group. Results: A significant difference was found in instrumentation time and canal transportation measures between the two groups. Wave one showed less canal transportation as compared with one shape, and the mean instrumentation time of wave one was significantly less than one shape. Conclusion: Reciprocating single-file systems was found to be faster with much less procedural errors and can hence be recommended for shaping the root canals of primary teeth. How to cite this article: Prabhakar AR, Yavagal C, Dixit K, Naik SV. Reciprocating vs Rotary Instrumentation in Pediatric Endodontics: Cone Beam Computed Tomographic Analysis of Deciduous Root Canals using Two Single-File Systems. Int J Clin Pediatr Dent 2016;9(1):45-49. PMID:27274155
DOE Office of Scientific and Technical Information (OSTI.GOV)
De Carlo, Francesco; Gürsoy, Doğa; Ching, Daniel J.
There is a widening gap between the fast advancement of computational methods for tomographic reconstruction and their successful implementation in production software at various synchrotron facilities. This is due in part to the lack of readily available instrument datasets and phantoms representative of real materials for validation and comparison of new numerical methods. Recent advancements in detector technology made sub-second and multi-energy tomographic data collection possible [1], but also increased the demand to develop new reconstruction methods able to handle in-situ [2] and dynamic systems [3] that can be quickly incorporated in beamline production software [4]. The X-ray Tomography Datamore » Bank, tomoBank, provides a repository of experimental and simulated datasets with the aim to foster collaboration among computational scientists, beamline scientists, and experimentalists and to accelerate the development and implementation of tomographic reconstruction methods for synchrotron facility production software by providing easy access to challenging dataset and their descriptors.« less
A maximum entropy reconstruction technique for tomographic particle image velocimetry
NASA Astrophysics Data System (ADS)
Bilsky, A. V.; Lozhkin, V. A.; Markovich, D. M.; Tokarev, M. P.
2013-04-01
This paper studies a novel approach for reducing tomographic PIV computational complexity. The proposed approach is an algebraic reconstruction technique, termed MENT (maximum entropy). This technique computes the three-dimensional light intensity distribution several times faster than SMART, using at least ten times less memory. Additionally, the reconstruction quality remains nearly the same as with SMART. This paper presents the theoretical computation performance comparison for MENT, SMART and MART, followed by validation using synthetic particle images. Both the theoretical assessment and validation of synthetic images demonstrate significant computational time reduction. The data processing accuracy of MENT was compared to that of SMART in a slot jet experiment. A comparison of the average velocity profiles shows a high level of agreement between the results obtained with MENT and those obtained with SMART.
Virtual endoscopic imaging of the spine.
Kotani, Toshiaki; Nagaya, Shigeyuki; Sonoda, Masaru; Akazawa, Tsutomu; Lumawig, Jose Miguel T; Nemoto, Tetsuharu; Koshi, Takana; Kamiya, Koshiro; Hirosawa, Naoya; Minami, Shohei
2012-05-20
Prospective trial of virtual endoscopy in spinal surgery. To investigate the utility of virtual endoscopy of the spine in conjunction with spinal surgery. Several studies have described clinical applications of virtual endoscopy to visualize the inside of the bronchi, paranasal sinus, stomach, small intestine, pancreatic duct, and bile duct, but, to date, no study has described the use of virtual endoscopy in the spine. Virtual endoscopy is a realistic 3-dimensional intraluminal simulation of tubular structures that is generated by postprocessing of computed tomographic data sets. Five patients with spinal disease were selected: 2 patients with degenerative disease, 2 patients with spinal deformity, and 1 patient with spinal injury. Virtual endoscopy software allows an observer to explore the spinal canal with a mouse, using multislice computed tomographic data. Our study found that virtual endoscopy of the spine has advantages compared with standard imaging methods because surgeons can noninvasively explore the spinal canal in all directions. Virtual endoscopy of the spine may be useful to surgeons for diagnosis, preoperative planning, and postoperative assessment by obviating the need to mentally construct a 3-dimensional picture of the spinal canal from 2-dimensional computed tomographic scans.
Lamb wave tomographic imaging system for aircraft structural health assessment
NASA Astrophysics Data System (ADS)
Schwarz, Willi G.; Read, Michael E.; Kremer, Matthew J.; Hinders, Mark K.; Smith, Barry T.
1999-01-01
A tomographic imaging system using ultrasonic Lamb waves for the nondestructive inspection of aircraft components such as wings and fuselage is being developed. The computer-based system provides large-area inspection capability by electronically scanning an array of transducers that can be easily attached to flat and curved surface without moving parts. Images of the inspected area are produced in near real time employing a tomographic reconstruction method adapted from seismological applications. Changes in material properties caused by structural flaws such as disbonds, corrosion, and fatigue cracks can be effectively detected and characterized utilizing this fast NDE technique.
Yoon, Seo Yeon; Kim, Je-Kyung; An, Young-Sil; Kim, Yong Wook
2015-01-01
Aphasia is one of the most common neurologic deficits occurring after stroke. Although the speech-language therapy is a mainstream option for poststroke aphasia, pharmacotherapy is recently being tried to modulate different neurotransmitter systems. However, the efficacy of those treatments is still controversial. We present a case of a 53-year-old female patient with Wernicke aphasia, after the old infarction in the territory of left middle cerebral artery for 8 years and the recent infarction in the right middle cerebral artery for 4 months. On the initial evaluation, the Aphasia Quotient in Korean version of the Western Aphasia Battery was 25.6 of 100. Baseline brain F-18 fluorodeoxyglucose positron emission tomographic images demonstrated a decreased cerebral metabolism in the left temporoparietal area and right temporal lobe. Donepezil hydrochloride, a reversible acetylcholinesterase inhibitor, was orally administered 5 mg/d for 6 weeks after the initial evaluation and was increased to 10 mg/d for the following 6 weeks. After the donepezil treatment, the patient showed improvement in language function, scoring 51.0 of 100 on Aphasia Quotient. A subtraction analysis of the brain F-18 fluorodeoxyglucose positron emission tomographic images after donepezil medication demonstrated increased uptake in both middle temporal gyri, extended to the occipital area and the left cerebellum. Thus, we suggest that donepezil can be an effective therapeutic choice for the treatment of Wernicke aphasia.
1986-03-10
and P. Frangos , "Inverse Scattering for Dielectric Media", Annual OSA Meeting, Wash. D.C., Oct. 1985. Invited Presentations 1. N. Farhat, "Tomographic...Optical Computing", DARPA Briefing, ~~April 1985. ... -7--.. , 1% If .% P . .% .% *-. 7777~14e 7-7. K-7 77 Theses 0 P.V. Frangos , "The Electromagnetic
Critical examination of the uniformity requirements for single-photon emission computed tomography.
O'Connor, M K; Vermeersch, C
1991-01-01
It is generally recognized that single-photon emission computed tomography (SPECT) imposes very stringent requirements on gamma camera uniformity to prevent the occurrence of ring artifacts. The purpose of this study was to examine the relationship between nonuniformities in the planar data and the magnitude of the consequential ring artifacts in the transaxial data, and how the perception of these artifacts is influenced by factors such as reconstruction matrix size, reconstruction filter, and image noise. The study indicates that the relationship between ring artifact magnitude and image noise is essentially independent of the acquisition or reconstruction matrix sizes, but is strongly dependent upon the type of smoothing filter applied during the reconstruction process. Furthermore, the degree to which a ring artifact can be perceived above image noise is dependent on the size and location of the nonuniformity in the planar data, with small nonuniformities (1-2 pixels wide) close to the center of rotation being less perceptible than those further out (8-20 pixels). Small defects or nonuniformities close to the center of rotation are thought to cause the greatest potential corruption to tomographic data. The study indicates that such may not be the case. Hence the uniformity requirements for SPECT may be less demanding than was previously thought.
NASA Astrophysics Data System (ADS)
Pablico-Lansigan, Michele H.; Situ, Shu F.; Samia, Anna Cristina S.
2013-05-01
Magnetic particle imaging (MPI) is an emerging biomedical imaging technology that allows the direct quantitative mapping of the spatial distribution of superparamagnetic iron oxide nanoparticles. MPI's increased sensitivity and short image acquisition times foster the creation of tomographic images with high temporal and spatial resolution. The contrast and sensitivity of MPI is envisioned to transcend those of other medical imaging modalities presently used, such as magnetic resonance imaging (MRI), X-ray scans, ultrasound, computed tomography (CT), positron emission tomography (PET) and single photon emission computed tomography (SPECT). In this review, we present an overview of the recent advances in the rapidly developing field of MPI. We begin with a basic introduction of the fundamentals of MPI, followed by some highlights over the past decade of the evolution of strategies and approaches used to improve this new imaging technique. We also examine the optimization of iron oxide nanoparticle tracers used for imaging, underscoring the importance of size homogeneity and surface engineering. Finally, we present some future research directions for MPI, emphasizing the novel and exciting opportunities that it offers as an important tool for real-time in vivo monitoring. All these opportunities and capabilities that MPI presents are now seen as potential breakthrough innovations in timely disease diagnosis, implant monitoring, and image-guided therapeutics.
Single photon emission computed tomography-guided Cerenkov luminescence tomography
NASA Astrophysics Data System (ADS)
Hu, Zhenhua; Chen, Xueli; Liang, Jimin; Qu, Xiaochao; Chen, Duofang; Yang, Weidong; Wang, Jing; Cao, Feng; Tian, Jie
2012-07-01
Cerenkov luminescence tomography (CLT) has become a valuable tool for preclinical imaging because of its ability of reconstructing the three-dimensional distribution and activity of the radiopharmaceuticals. However, it is still far from a mature technology and suffers from relatively low spatial resolution due to the ill-posed inverse problem for the tomographic reconstruction. In this paper, we presented a single photon emission computed tomography (SPECT)-guided reconstruction method for CLT, in which a priori information of the permissible source region (PSR) from SPECT imaging results was incorporated to effectively reduce the ill-posedness of the inverse reconstruction problem. The performance of the method was first validated with the experimental reconstruction of an adult athymic nude mouse implanted with a Na131I radioactive source and an adult athymic nude mouse received an intravenous tail injection of Na131I. A tissue-mimic phantom based experiment was then conducted to illustrate the ability of the proposed method in resolving double sources. Compared with the traditional PSR strategy in which the PSR was determined by the surface flux distribution, the proposed method obtained much more accurate and encouraging localization and resolution results. Preliminary results showed that the proposed SPECT-guided reconstruction method was insensitive to the regularization methods and ignored the heterogeneity of tissues which can avoid the segmentation procedure of the organs.
Nishimura, T; Uehara, T; Shimonagata, T; Nagata, S; Haze, K
1994-01-01
This study was undertaken to evaluate the relationships, between myocardial perfusion and metabolism. Simultaneous beta-methyl-p(123I)iodophenylpentadecanoic acid (123I-BMIPP) and thallium 201 myocardial single-photon emission computed tomography (SPECT) were performed in 25 patients with myocardial infarction (group A) and 16 patients with hypertrophic cardiomyopathy (group B). The severity scores of 123I-BMIPP and 201Tl myocardial SPECT images were evaluated semiquantitatively by segmental analysis. In Group A, dissociations between thallium- and 123I-BMIPP-imaged defects were frequently observed in patients with successful reperfusion compared with those with no reperfusion and those with reinfarction. In four patients with successful reperfusion, repeated 123I-BMIPP and 201Tl myocardial SPECT showed gradual improvement of the 123I-BMIPP severity score compared with the thallium severity score. In group B, dissociations between thallium- and 123I-BMIPP-imaged defects were also demonstrated in hypertrophic myocardium. In addition, nonhypertrophic myocardium also had decreased 123I-BMIPP uptake. In groups A and B, 123I-BMIPP severity scores correlated well with left ventricular function compared with thallium severity scores. These findings indicate that 123I-BMIPP is a suitable agent for the assessment of functional integrity, because left ventricular wall motion is energy dependent and 123I-BMIPP may reflect an aspect of myocardial energy production. This agent may be useful for the early detection and patient management of various heart diseases as an alternative to positron emission tomographic study.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rathore, Kavita, E-mail: kavira@iitk.ac.in, E-mail: pmunshi@iitk.ac.in, E-mail: sudeepb@iitk.ac.in; Munshi, Prabhat, E-mail: kavira@iitk.ac.in, E-mail: pmunshi@iitk.ac.in, E-mail: sudeepb@iitk.ac.in; Bhattacharjee, Sudeep, E-mail: kavira@iitk.ac.in, E-mail: pmunshi@iitk.ac.in, E-mail: sudeepb@iitk.ac.in
A new non-invasive diagnostic system is developed for Microwave Induced Plasma (MIP) to reconstruct tomographic images of a 2D emission profile. A compact MIP system has wide application in industry as well as research application such as thrusters for space propulsion, high current ion beams, and creation of negative ions for heating of fusion plasma. Emission profile depends on two crucial parameters, namely, the electron temperature and density (over the entire spatial extent) of the plasma system. Emission tomography provides basic understanding of plasmas and it is very useful to monitor internal structure of plasma phenomena without disturbing its actualmore » processes. This paper presents development of a compact, modular, and versatile Optical Emission Tomography (OET) tool for a cylindrical, magnetically confined MIP system. It has eight slit-hole cameras and each consisting of a complementary metal–oxide–semiconductor linear image sensor for light detection. The optical noise is reduced by using aspheric lens and interference band-pass filters in each camera. The entire cylindrical plasma can be scanned with automated sliding ring mechanism arranged in fan-beam data collection geometry. The design of the camera includes a unique possibility to incorporate different filters to get the particular wavelength light from the plasma. This OET system includes selected band-pass filters for particular argon emission 750 nm, 772 nm, and 811 nm lines and hydrogen emission H{sub α} (656 nm) and H{sub β} (486 nm) lines. Convolution back projection algorithm is used to obtain the tomographic images of plasma emission line. The paper mainly focuses on (a) design of OET system in detail and (b) study of emission profile for 750 nm argon emission lines to validate the system design.« less
Kokosi, Maria; Lo, Pechin; Kim, Hyun J.; Ravenel, James G.; Meyer, Cristopher; Goldin, Jonathan; Lee, Hye-Seung; Strange, Charlie; McCormack, Francis X.
2016-01-01
Rationale: The Multicenter International Lymphangioleiomyomatosis Efficacy and Safety of Sirolimus (MILES) trial demonstrated that sirolimus stabilized lung function and improved measures of functional performance and quality of life in patients with lymphangioleiomyomatosis. The physiologic mechanisms of these beneficial actions of sirolimus are incompletely understood. Objectives: To prospectively determine the longitudinal computed tomographic lung imaging correlates of lung function change in MILES patients treated with placebo or sirolimus. Methods: We determined the baseline to 12-month change in computed tomographic image–derived lung volumes and the volume of the lung occupied by cysts in the 31 MILES participants (17 in sirolimus group, 14 in placebo group) with baseline and 12-month scans. Measurements and Main Results: There was a trend toward an increase in median expiratory cyst volume percentage in the placebo group and a reduction in the sirolimus group (+2.68% vs. +0.97%, respectively; P = 0.10). The computed tomographic image–derived residual volume and the ratio of residual volume to total lung capacity increased more in the placebo group than in the sirolimus group (+214.4 ml vs. +2.9 ml [P = 0.054] and +0.05 ml vs. −0.01 ml [P = 0.0498], respectively). A Markov transition chain analysis of respiratory cycle cyst volume changes revealed greater dynamic variation in the sirolimus group than in the placebo group at the 12-month time point. Conclusions: Collectively, these data suggest that sirolimus attenuates progressive gas trapping in lymphangioleiomyomatosis, consistent with a beneficial effect of the drug on airflow obstruction. We speculate that a reduction in lymphangioleiomyomatosis cell burden around small airways and cyst walls alleviates progressive airflow limitation and facilitates cyst emptying. PMID:26799509
Argula, Rahul G; Kokosi, Maria; Lo, Pechin; Kim, Hyun J; Ravenel, James G; Meyer, Cristopher; Goldin, Jonathan; Lee, Hye-Seung; Strange, Charlie; McCormack, Francis X
2016-03-01
The Multicenter International Lymphangioleiomyomatosis Efficacy and Safety of Sirolimus (MILES) trial demonstrated that sirolimus stabilized lung function and improved measures of functional performance and quality of life in patients with lymphangioleiomyomatosis. The physiologic mechanisms of these beneficial actions of sirolimus are incompletely understood. To prospectively determine the longitudinal computed tomographic lung imaging correlates of lung function change in MILES patients treated with placebo or sirolimus. We determined the baseline to 12-month change in computed tomographic image-derived lung volumes and the volume of the lung occupied by cysts in the 31 MILES participants (17 in sirolimus group, 14 in placebo group) with baseline and 12-month scans. There was a trend toward an increase in median expiratory cyst volume percentage in the placebo group and a reduction in the sirolimus group (+2.68% vs. +0.97%, respectively; P = 0.10). The computed tomographic image-derived residual volume and the ratio of residual volume to total lung capacity increased more in the placebo group than in the sirolimus group (+214.4 ml vs. +2.9 ml [P = 0.054] and +0.05 ml vs. -0.01 ml [P = 0.0498], respectively). A Markov transition chain analysis of respiratory cycle cyst volume changes revealed greater dynamic variation in the sirolimus group than in the placebo group at the 12-month time point. Collectively, these data suggest that sirolimus attenuates progressive gas trapping in lymphangioleiomyomatosis, consistent with a beneficial effect of the drug on airflow obstruction. We speculate that a reduction in lymphangioleiomyomatosis cell burden around small airways and cyst walls alleviates progressive airflow limitation and facilitates cyst emptying.
The Use of Chest Computed Tomographic Angiography in Blunt Trauma Pediatric Population.
Hasadia, Rabea; DuBose, Joseph; Peleg, Kobi; Stephenson, Jacob; Givon, Adi; Kessel, Boris
2018-02-05
Blunt chest trauma in children is common. Although rare, associated major thoracic vascular injuries (TVIs) are lethal potential sequelae of these mechanisms. The preferred study for definitive diagnosis of TVI in stable patients is computed tomographic angiography imaging of the chest. This imaging modality is, however, associated with high doses of ionizing radiation that represent significant carcinogenic risk for pediatric patients. The aim of the present investigation was to define the incidence of TVI among blunt pediatric trauma patients in an effort to better elucidate the usefulness of computed tomographic angiography use in this population. A retrospective cohort study was conducted including all blunt pediatric (age < 14 y) trauma victims registered in Israeli National Trauma Registry maintained by Gertner Institute for Epidemiology and Health Policy Research between the years 1997 and 2015. Data collected included age, sex, mechanism of injury, Glasgow Coma Scale, Injury Severity Score, and incidence of chest named vessel injuries. Statistical analysis was performed using SAS statistical software version 9.2 (SAS Institute Inc, Cary, NC). Among 433,325 blunt trauma victims, 119,821patients were younger than 14 years. Twelve (0.0001%, 12/119821) of these children were diagnosed with TVI. The most common mechanism in this group was pedestrian hit by a car. Mortality was 41.7% (5/12). Thoracic vascular injury is exceptionally rare among pediatric blunt trauma victims but does contribute to the high morbidity and mortality seen with blunt chest trauma. Computed tomographic angiography, with its associated radiation exposure risk, should not be used as a standard tool after trauma in injured children. Clinical protocols are needed in this population to minimize radiation risk while allowing prompt identification of life-threatening injuries.
Rodriguez-Lorenzo, Andres; Audolfsson, Thorir; Wong, Corrine; Cheng, Angela; Arbique, Gary; Nowinski, Daniel; Rozen, Shai
2015-10-01
The aim of this study was to evaluate the contribution of a single unilateral facial vein in the venous outflow of total-face allograft using three-dimensional computed tomographic imaging techniques to further elucidate the mechanisms of venous complications following total-face transplant. Full-face soft-tissue flaps were harvested from fresh adult human cadavers. A single facial vein was identified and injected distally to the submandibular gland with a radiopaque contrast (barium sulfate/gelatin mixture) in every specimen. Following vascular injections, three-dimensional computed tomographic venographies of the faces were performed. Images were viewed using TeraRecon Software (Teracon, Inc., San Mateo, CA, USA) allowing analysis of the venous anatomy and perfusion in different facial subunits by observing radiopaque filling venous patterns. Three-dimensional computed tomographic venographies demonstrated a venous network with different degrees of perfusion in subunits of the face in relation to the facial vein injection side: 100% of ipsilateral and contralateral forehead units, 100% of ipsilateral and 75% of contralateral periorbital units, 100% of ipsilateral and 25% of contralateral cheek units, 100% of ipsilateral and 75% of contralateral nose units, 100% of ipsilateral and 75% of contralateral upper lip units, 100% of ipsilateral and 25% of contralateral lower lip units, and 50% of ipsilateral and 25% of contralateral chin units. Venographies of the full-face grafts revealed better perfusion in the ipsilateral hemifaces from the facial vein in comparison with the contralateral hemifaces. Reduced perfusion was observed mostly in the contralateral cheek unit and contralateral lower face including the lower lip and chin units. Copyright © 2015 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Hopper, Richard A; Sandercoe, Gavin; Woo, Albert; Watts, Robyn; Kelley, Patrick; Ettinger, Russell E; Saltzman, Babette
2010-11-01
Le Fort III distraction requires generation of bone in the pterygomaxillary region. The authors performed retrospective digital analysis on temporal fine-cut computed tomographic images to quantify both radiographic evidence of pterygomaxillary region bone formation and relative maxillary stability. Fifteen patients with syndromic midface hypoplasia were included in the study. The average age of the patients was 8.7 years; 11 had either Crouzon or Apert syndrome. The average displacement of the maxilla during distraction was 16.2 mm (range, 7 to 31 mm). Digital analysis was performed on fine-cut computed tomographic scans before surgery, at device removal, and at annual follow-up. Seven patients also had mid-consolidation computed tomographic scans. Relative maxillary stability and density of radiographic bone in the pterygomaxillary region were calculated between each scan. There was no evidence of clinically significant maxillary relapse, rotation, or growth between the end of consolidation and 1-year follow-up, other than a relatively small 2-mm subnasal maxillary vertical growth. There was an average radiographic ossification of 0.5 mm/mm advancement at the time of device removal, with a 25th percentile value of 0.3 mm/mm. The time during consolidation that each patient reached the 25th percentile of pterygomaxillary region bone density observed in this series of clinically stable advancements ranged from 1.3 to 9.8 weeks (average, 3.7 weeks). There was high variability in the amount of bone formed in the pterygomaxillary region associated with clinical stability of the advanced Le Fort III segment. These data suggest that a subsection of patients generate the minimal amount of pterygomaxillary region bone formation associated with advancement stability as early as 4 weeks into consolidation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stratton, J.R.; Ritchie, J.L.
Aspirin plus dipyridamole reduces platelet accumulation on short-term Dacron vascular grafts in man. To determine whether drug inhibition of platelet deposition is sustained on older grafts, we studied 18 men aged 41 to 87 years who had Dacron aortic bifurcation grafts in place a mean of 43.4 months (range 9.8 to 121.0) before and during short-term therapy with aspirin (325 mg tid) plus dipyridamole (75 mg tid). During both the baseline and drug studies, indium-111 (/sup 111/In) platelet deposition was quantitated by two techniques, standard planar imaging performed at 24, 48, and 72 hr after injection of platelets and singlemore » photon emission computed tomographic imaging performed at 24 and 72 hr after injection. All analyses were performed in a blinded fashion. On both the planar and tomographic images, platelet accumulation on the graft was quantitated by a graft/blood ratio that compared activity in the graft to simultaneously collected whole blood /sup 111/In platelet activity. Aspirin plus dipyridamole reduced the tomographic graft/blood ratio at 24 hr (20.6 +/- 3.5 vs 17.3 +/- 2.5) (+/-SEM) and at 72 hr (29.0 +/- 4.8 vs 25.0 +/- 4.1) after injection of platelets (p = .02). Dacron vascular grafts. Similarly, the planar graft/blood ratio was reduced at 24 hr (2.7 +/- 0.5 vs 2.4 +/- 0.5), 48 hr (3.7 +/- 0.9 vs 3.1 +/- 0.7), and 72 hr (4.0 +/- 0.9 vs 3.6 +/- 0.8) (p = .04). We conclude that aspirin (325 mg tid) plus dipyridamole (75 mg tid) reduces platelet accumulation on long-term Dacron vascular grafts.« less
Overview of the Benzene and Other Toxics Exposure (BEE-TEX) Field Study.
Olaguer, Eduardo P
2015-01-01
The Benzene and other Toxics Exposure (BEE-TEX) field study was an experimental campaign designed to demonstrate novel methods for measuring ambient concentrations of hazardous air pollutants (HAPs) in real time and to attribute these concentrations to quantified releases from specific emission points in industrial facilities while operating outside facility fence lines. BEE-TEX was conducted in February 2015 at three neighboring communities in the Houston Ship Channel of Texas, where a large number of petrochemical facilities are concentrated. The novel technologies deployed during BEE-TEX included: (1) tomographic remote sensing based on differential optical absorption spectroscopy; (2) real-time broadcasting of ambient air monitoring data over the World Wide Web; (3) real-time source attribution and quantification of HAP emissions based on either tomographic or mobile measurement platforms; and (4) the use of cultured human lung cells in vitro as portable indicators of HAP exposure.
Overview of the Benzene and Other Toxics Exposure (BEE-TEX) Field Study
Olaguer, Eduardo P.
2015-01-01
The Benzene and other Toxics Exposure (BEE-TEX) field study was an experimental campaign designed to demonstrate novel methods for measuring ambient concentrations of hazardous air pollutants (HAPs) in real time and to attribute these concentrations to quantified releases from specific emission points in industrial facilities while operating outside facility fence lines. BEE-TEX was conducted in February 2015 at three neighboring communities in the Houston Ship Channel of Texas, where a large number of petrochemical facilities are concentrated. The novel technologies deployed during BEE-TEX included: (1) tomographic remote sensing based on differential optical absorption spectroscopy; (2) real-time broadcasting of ambient air monitoring data over the World Wide Web; (3) real-time source attribution and quantification of HAP emissions based on either tomographic or mobile measurement platforms; and (4) the use of cultured human lung cells in vitro as portable indicators of HAP exposure. PMID:26549972
Feasibility of hydrogen density estimation from tomographic sensing of Lyman alpha emission
NASA Astrophysics Data System (ADS)
Waldrop, L.; Kamalabadi, F.; Ren, D.
2015-12-01
In this work, we describe the scientific motivation, basic principles, and feasibility of a new approach to the estimation of neutral hydrogen (H) density in the terrestrial exosphere based on the 3-D tomographic sensing of optically thin H emission at 121.6 nm (Lyman alpha). In contrast to existing techniques, Lyman alpha tomography allows for model-independent reconstruction of the underlying H distribution in support of investigations regarding the origin and time-dependent evolution of exospheric structure. We quantitatively describe the trade-off space between the measurement sampling rate, viewing geometry, and the spatial and temporal resolution of the reconstruction that is supported by the data. We demonstrate that this approach is feasible from either earth-orbiting satellites such as the stereoscopic NASA TWINS mission or from a CubeSat platform along a trans-exosphere trajectory such as that enabled by the upcoming Exploration Mission 1 launch.
Ultrasoft x-ray imaging system for the National Spherical Torus Experiment
NASA Astrophysics Data System (ADS)
Stutman, D.; Finkenthal, M.; Soukhanovskii, V.; May, M. J.; Moos, H. W.; Kaita, R.
1999-01-01
A spectrally resolved ultrasoft x-ray imaging system, consisting of arrays of high resolution (<2 Å) and throughput (⩾tens of kHz) miniature monochromators, and based on multilayer mirrors and absolute photodiodes, is being designed for the National Spherical Torus Experiment. Initially, three poloidal arrays of diodes filtered for C 1s-np emission will be implemented for fast tomographic imaging of the colder start-up plasmas. Later on, mirrors tuned to the C Lyα emission will be added in order to enable the arrays to "see" the periphery through the hot core and to study magnetohydrodynamic activity and impurity transport in this region. We also discuss possible core diagnostics, based on tomographic imaging of the Lyα emission from the plume of recombined, low Z impurity ions left by neutral beams or fueling pellets. The arrays can also be used for radiated power measurements and to map the distribution of high Z impurities injected for transport studies. The performance of the proposed system is illustrated with results from test channels on the CDX-U spherical torus at Princeton Plasma Physics Laboratory.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bielecki, J.; Scholz, M.; Drozdowicz, K.
A method of tomographic reconstruction of the neutron emissivity in the poloidal cross section of the Joint European Torus (JET, Culham, UK) tokamak was developed. Due to very limited data set (two projection angles, 19 lines of sight only) provided by the neutron emission profile monitor (KN3 neutron camera), the reconstruction is an ill-posed inverse problem. The aim of this work consists in making a contribution to the development of reliable plasma tomography reconstruction methods that could be routinely used at JET tokamak. The proposed method is based on Phillips-Tikhonov regularization and incorporates a priori knowledge of the shape ofmore » normalized neutron emissivity profile. For the purpose of the optimal selection of the regularization parameters, the shape of normalized neutron emissivity profile is approximated by the shape of normalized electron density profile measured by LIDAR or high resolution Thomson scattering JET diagnostics. In contrast with some previously developed methods of ill-posed plasma tomography reconstruction problem, the developed algorithms do not include any post-processing of the obtained solution and the physical constrains on the solution are imposed during the regularization process. The accuracy of the method is at first evaluated by several tests with synthetic data based on various plasma neutron emissivity models (phantoms). Then, the method is applied to the neutron emissivity reconstruction for JET D plasma discharge #85100. It is demonstrated that this method shows good performance and reliability and it can be routinely used for plasma neutron emissivity reconstruction on JET.« less
Time-Dependent Computed Tomographic Perfusion Thresholds for Patients With Acute Ischemic Stroke.
d'Esterre, Christopher D; Boesen, Mari E; Ahn, Seong Hwan; Pordeli, Pooneh; Najm, Mohamed; Minhas, Priyanka; Davari, Paniz; Fainardi, Enrico; Rubiera, Marta; Khaw, Alexander V; Zini, Andrea; Frayne, Richard; Hill, Michael D; Demchuk, Andrew M; Sajobi, Tolulope T; Forkert, Nils D; Goyal, Mayank; Lee, Ting Y; Menon, Bijoy K
2015-12-01
Among patients with acute ischemic stroke, we determine computed tomographic perfusion (CTP) thresholds associated with follow-up infarction at different stroke onset-to-CTP and CTP-to-reperfusion times. Acute ischemic stroke patients with occlusion on computed tomographic angiography were acutely imaged with CTP. Noncontrast computed tomography and magnectic resonance diffusion-weighted imaging between 24 and 48 hours were used to delineate follow-up infarction. Reperfusion was assessed on conventional angiogram or 4-hour repeat computed tomographic angiography. Tmax, cerebral blood flow, and cerebral blood volume derived from delay-insensitive CTP postprocessing were analyzed using receiver-operator characteristic curves to derive optimal thresholds for combined patient data (pooled analysis) and individual patients (patient-level analysis) based on time from stroke onset-to-CTP and CTP-to-reperfusion. One-way ANOVA and locally weighted scatterplot smoothing regression was used to test whether the derived optimal CTP thresholds were different by time. One hundred and thirty-two patients were included. Tmax thresholds of >16.2 and >15.8 s and absolute cerebral blood flow thresholds of <8.9 and <7.4 mL·min(-1)·100 g(-1) were associated with infarct if reperfused <90 min from CTP with onset <180 min. The discriminative ability of cerebral blood volume was modest. No statistically significant relationship was noted between stroke onset-to-CTP time and the optimal CTP thresholds for all parameters based on discrete or continuous time analysis (P>0.05). A statistically significant relationship existed between CTP-to-reperfusion time and the optimal thresholds for cerebral blood flow (P<0.001; r=0.59 and 0.77 for gray and white matter, respectively) and Tmax (P<0.001; r=-0.68 and -0.60 for gray and white matter, respectively) parameters. Optimal CTP thresholds associated with follow-up infarction depend on time from imaging to reperfusion. © 2015 American Heart Association, Inc.
Pineal region tumors: computed tomographic-pathologic spectrum
DOE Office of Scientific and Technical Information (OSTI.GOV)
Futrell, N.N.; Osborn, A.G.; Cheson. B.D.
While several computed tomographic (CT) studies of posterior third ventricular neoplasms have included descriptions of pineal tumors, few reports have concentrated on these uncommon lesions. Some authors have asserted that the CT appearance of many pineal tumors is virtually pathognomonic. A series of nine biopsy-proved pineal gland and eight other presumed tumors is presented that illustrates their remarkable heterogeneity in both histopathologic and CT appearance. These tumors included germinomas, teratocarcinomas, hamartomas, and other varieties. They had variable margination, attentuation, calcification, and suprasellar extension. Germinomas have the best response to radiation therapy. Biopsy of pineal region tumors is now feasible andmore » is recommended for treatment planning.« less
Normal cord in infants and children examined with computed tomographic metrizamide myelography.
Resjö, I M; Harwood-Nash, D C; Fitz, C R; Chuang, S
1979-03-01
Computed tomographic metrizamide myelography (CTMM) was performed on 25 infants and children and 2 adults with normal spinal cords. Both the cord and the cauda equina were precisely outlined. The most detailed information was obtained with a small window setting, with the image subsequently magnified and color-reversed. Hounsfield-unit measurements alone were inaccurate. Advantages of CTMM include: high accuracy in demonstrating the intrathecal contents of the spine; less need for general anesthesia; and the need for a smaller amount of water-soluble contrast material than in conventional myelography. In selected cases of intraspinal abnormality in children, CTMM is recommended.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nakagawa, Motoo, E-mail: lmloltlolol@gmail.com; Ogino, Hiroyuki; Shimohira, Masashi
2009-05-15
A case of acute necrotizing pancreatitis due to Mycoplasma pneumoniae infection was treated in an 8-year-old girl. She experienced acute pancreatitis during treatment for M. pneumoniae. Contrast-enhanced computed tomographic scan revealed necrotizing pancreatitis. The computed tomographic severity index was 8 points (grade E). A protease inhibitor, ulinastatin, was provided via intravenous infusion but was ineffective. Continuous regional arterial infusion therapy was provided with gabexate mesilate (FOY-007, a protease inhibitor) and meropenem trihydrate, and the pancreatitis improved. This case suggests that infusion therapy is safe and useful in treating necrotizing pancreatitis in children.
Tafti, Bashir Akhavan; Berenji, Gholam R; Santiago, Silverio; Barack, Bruce M
2012-11-01
Computed tomographic pulmonary angiography has become the diagnostic procedure of choice in patients suspected of having a pulmonary embolus. However, intrapulmonary shunting of blood in a variety of pathologic conditions can cause suboptimal opacification of the pulmonary arterial circulation and result in a suboptimal or even nondiagnostic study. Radiologists should be aware of these conditions and be familiar with positioning techniques to minimize such shunting. We report a patient suspected of having pulmonary embolism, in whom a preexisting unilateral arteriovenous malformation prevented adequate evaluation of the pulmonary circulation. Positioning the patient in the contralateral decubitus position significantly enhanced image quality.
Lumbar artery perforators: an anatomical study based on computed tomographic angiography imaging.
Sommeling, Casper Emile; Colebunders, Britt; Pardon, Heleen E; Stillaert, Filip B; Blondeel, Phillip N; van Landuyt, Koenraad
2017-08-01
The free lumbar artery perforator flap has recently been introduced as a potentially valuable option for autologous breast reconstruction in a subset of patients. Up to date, few anatomical studies, exploring the lumbar region as a donor site for perforator- based flaps, have been conducted. An anatomical study of the position of the dominant lumbar artery perforator was performed, using the preoperative computed tomographic angiography images of 24 autologous breast reconstruction patients. In total, 61 dominant perforators were determined, 28 on the left and 33 on the right side. A radiologist defined the position of the perforator as coordinates in an xy-grid. Dominant perforators were shown to originate from the lumbar arteries at the level of lumbar vertebrae three or four. Remarkably, approximately 85% of these lumbar artery perforators enter the skin at 7-10 cm lateral from the midline (mean left 8.6 cm, right 8.2 cm). This study concludes a rather constant position of the dominant perforator. Therefore, preoperative-computed tomographic angiography is not always essential to find this perforator and Doppler ultrasound could be considered as an alternative, thereby carefully assessing all advantages and disadvantages inherent to either of these imaging methods.
Yin, Ningbei; Wu, Jiajun; Chen, Bo; Song, Tao; Ma, Hengyuan; Zhao, Zhenmin; Wang, Yongqian; Li, Haidong; Wu, Di
2015-03-01
Plastic surgeons have attempted various ways to rebuild the aesthetic subunits of the upper lip in patients with cleft lip with less than perfect results in most cases. We propose that repairing the 3 muscle tension line groups in the nasolabial complex will have improved aesthetic results. Micro-computed tomographic scans were performed on the nasolabial tissues of 5 normal aborted fetuses and used to construct a 3-dimensional model to study the nasolabial muscle complex structure. The micro-computed tomographic (CT) scans showed the close relationship and interaction between the muscle fibers of nasalis, pars peripheralis, levator labii superioris, and pars marginalis. Based on the 2-dimensional images obtained from the micro-computed tomographic scans, we suggest the concept of nasolabial muscle complex and muscle tension line group theory: there is a close relationship among the alar part of the nasalis, depressor septi muscle, orbicularis oris muscle, and levator labii superioris alaeque nasi. The tension line groups are 3 tension line structures in the nasolabial muscle complex that interlock with each other at the intersections and maintain the specific shape and aesthetics of the lip and nose.
Chen, Min-jie; Yang, Chi; Qiu, Ya-ting; Zhou, Qin; Huang, Dong; Shi, Hui-min
2014-09-01
The objectives of this study were to introduce the classification of osteochondroma of the mandibular condyle based on computed tomographic images and to present our treatment experiences. From January 2002 and December 2012, a total of 61 patients with condylar osteochondroma were treated in our division. Both clinical and radiologic aspects were reviewed. The average follow-up period was 24.3 months with a range of 6 to 120 months. Two types of condylar osteochondroma were presented: type 1 (protruding expansion) in 50 patients (82.0%) and type 2 (globular expansion) in 11 patients (18.0%). Type 1 condylar osteochondroma presented 5 forms: anterior/anteromedial (58%), posterior/posteromedial (6%), medial (16%), lateral (6%), and gigantic (14%). Local resection was performed on patients with type 1 condylar osteochondroma. Subtotal condylectomy/total condylectomy using costochondral graft reconstruction with/without orthognathic surgeries was performed on patients with type 2 condylar osteochondroma. During the follow-up period, tumor reformation, condyle absorption, and new deformity were not detected. The patients almost reattained facial symmetry. Preoperative classification based on computed tomographic images will help surgeons to choose the suitable surgical procedure to treat the condylar osteochondroma.
Photoacoustic imaging of fluorophores using pump-probe excitation
Märk, Julia; Schmitt, Franz-Josef; Theiss, Christoph; Dortay, Hakan; Friedrich, Thomas; Laufer, Jan
2015-01-01
A pump-probe technique for the detection of fluorophores in tomographic PA images is introduced. It is based on inducing stimulated emission in fluorescent molecules, which in turn modulates the amount of thermalized energy, and hence the PA signal amplitude. A theoretical model of the PA signal generation in fluorophores is presented and experimentally validated on cuvette measurements made in solutions of Rhodamine 6G, a fluorophore of known optical and molecular properties. The application of this technique to deep tissue tomographic PA imaging is demonstrated by determining the spatial distribution of a near-infrared fluorophore in a tissue phantom. PMID:26203378
DOE Office of Scientific and Technical Information (OSTI.GOV)
Laughlin, J.S.; Benua, R.S.; Tilbury, R.S.
1978-09-30
Progress is reported on biomedical studies using cyclotron-produced /sup 18/F, /sup 15/O, /sup 11/C, /sup 13/N, /sup 52/Fe, /sup 38/K, /sup 206/Bi, /sup 73/Se, /sup 53/Co, and /sup 43/K. The following research projects are described: tumor detection and diagnosis; neurological studies; radiopharmaceutical development; /sup 38/K as an indicator of blood flow to the myocardium; dosimetry for internally deposited isotopes in animals and man; cyclotron development; positron tomographic imaging with the TOKIM System; and review of positron emission transaxial tomograph instruments. (HLW)
3D Printing of Plant Golgi Stacks from Their Electron Tomographic Models.
Mai, Keith Ka Ki; Kang, Madison J; Kang, Byung-Ho
2017-01-01
Three-dimensional (3D) printing is an effective tool for preparing tangible 3D models from computer visualizations to assist in scientific research and education. With the recent popularization of 3D printing processes, it is now possible for individual laboratories to convert their scientific data into a physical form suitable for presentation or teaching purposes. Electron tomography is an electron microscopy method by which 3D structures of subcellular organelles or macromolecular complexes are determined at nanometer-level resolutions. Electron tomography analyses have revealed the convoluted membrane architectures of Golgi stacks, chloroplasts, and mitochondria. But the intricacy of their 3D organizations is difficult to grasp from tomographic models illustrated on computer screens. Despite the rapid development of 3D printing technologies, production of organelle models based on experimental data with 3D printing has rarely been documented. In this chapter, we present a simple guide to creating 3D prints of electron tomographic models of plant Golgi stacks using the two most accessible 3D printing technologies.
Image processing pipeline for synchrotron-radiation-based tomographic microscopy.
Hintermüller, C; Marone, F; Isenegger, A; Stampanoni, M
2010-07-01
With synchrotron-radiation-based tomographic microscopy, three-dimensional structures down to the micrometer level can be visualized. Tomographic data sets typically consist of 1000 to 1500 projections of 1024 x 1024 to 2048 x 2048 pixels and are acquired in 5-15 min. A processing pipeline has been developed to handle this large amount of data efficiently and to reconstruct the tomographic volume within a few minutes after the end of a scan. Just a few seconds after the raw data have been acquired, a selection of reconstructed slices is accessible through a web interface for preview and to fine tune the reconstruction parameters. The same interface allows initiation and control of the reconstruction process on the computer cluster. By integrating all programs and tools, required for tomographic reconstruction into the pipeline, the necessary user interaction is reduced to a minimum. The modularity of the pipeline allows functionality for new scan protocols to be added, such as an extended field of view, or new physical signals such as phase-contrast or dark-field imaging etc.
Browsing Software of the Visible Korean Data Used for Teaching Sectional Anatomy
ERIC Educational Resources Information Center
Shin, Dong Sun; Chung, Min Suk; Park, Hyo Seok; Park, Jin Seo; Hwang, Sung Bae
2011-01-01
The interpretation of computed tomographs (CTs) and magnetic resonance images (MRIs) to diagnose clinical conditions requires basic knowledge of sectional anatomy. Sectional anatomy has traditionally been taught using sectioned cadavers, atlases, and/or computer software. The computer software commonly used for this subject is practical and…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pettersson, H.; Harwood-Nash, D.C.; Fitz, C.R.
1982-01-01
A retrospective examination was performed to assess the accuracy of metrizamide myelography (MM) and computed tomographic metrizamide myelography (CTMM) in scoliosis. Of 81 consecutive scoliotic children studied by myelography, 30 had only MM while the remaining 51 had CTMM immediately afterward. CTMM added esential diagnostic information in 13 cases of dysraphism and 4 cases, both methods gave the same imformation. The outhors conclude that in patients with severe scoliosis, dysraphism, and scoliosis with localized neurological disturbances, CTMM should always be added to MM or be the only examination; while in idiopathic scoliosis with vague neurological disturbances a survey of themore » entire spine is essential, preferably with MM.« less
Hariharavel, V. P.; Kumar, A. Ashok; Ganesh, C.; Aravindhan, R.
2014-01-01
Anatomic and internal morphology of a root canal system is more complex and differs for each individual tooth of which mandibular premolars have earned the reputation for having aberrant anatomy. The occurrence of three canals with three separate foramina in mandibular second premolars is very rare. A wider knowledge on both clinical and radiological anatomy especially spiral computed tomographic is absolutely essential for the success of endodontic treatment. These teeth may require skillful and special root canal special shaping and obturating techniques. This paper reports an unusual case of a mandibular second premolar with atypical canal pattern that was successfully treated endodontically. PMID:25101187
Initial evaluation of discrete orthogonal basis reconstruction of ECT images
DOE Office of Scientific and Technical Information (OSTI.GOV)
Moody, E.B.; Donohue, K.D.
1996-12-31
Discrete orthogonal basis restoration (DOBR) is a linear, non-iterative, and robust method for solving inverse problems for systems characterized by shift-variant transfer functions. This simulation study evaluates the feasibility of using DOBR for reconstructing emission computed tomographic (ECT) images. The imaging system model uses typical SPECT parameters and incorporates the effects of attenuation, spatially-variant PSF, and Poisson noise in the projection process. Sample reconstructions and statistical error analyses for a class of digital phantoms compare the DOBR performance for Hartley and Walsh basis functions. Test results confirm that DOBR with either basis set produces images with good statistical properties. Nomore » problems were encountered with reconstruction instability. The flexibility of the DOBR method and its consistent performance warrants further investigation of DOBR as a means of ECT image reconstruction.« less
Lithographed spectrometers for tomographic line mapping of the Epoch of Reionization
NASA Astrophysics Data System (ADS)
O'Brient, R.; Bock, J. J.; Bradford, C. M.; Crites, A.; Duan, R.; Hailey-Dunsheath, S.; Hunacek, J.; LeDuc, R.; Shirokoff, E.; Staniszewski, Z.; Turner, A.; Zemcov, M.
2014-08-01
The Tomographic Ionized carbon Mapping Experiment (TIME) is a multi-phased experiment that will topographically map [CII] emission from the Epoch of Reionization. We are developing lithographed spectrometers that couple to TES bolometers in anticipation of the second generation instrument. Our design intentionally mirrors many features of the parallel SuperSpec project, inductively coupling power from a trunk-line microstrip onto half-wave resonators. The resonators couple to a rat-race hybrids that feeds TES bolometers. Our 25 channel prototype shows spectrally positioned lines roughly matching design with a receiver optical efficiency of 15-20%, a level that is dominated by loss in components outside the spectrometer.
Dynamic Positron Emission Tomography [PET] in Man Using Small Bismuth Germanate Crystals
DOE R&D Accomplishments Database
Derenzo, S. E.; Budinger, T. F.; Huesman, R. H.; Cahoon, J. L.
1982-04-01
Primary considerations for the design of positron emission tomographs for medical studies in humans are the need for high imaging sensitivity, whole organ coverage, good spatial resolution, high maximum data rates, adequate spatial sampling with minimum mechanical motion, shielding against out of plane activity, pulse height discrimination against scattered photons, and timing discrimination against accidental coincidences. We discuss the choice of detectors, sampling motion, shielding, and electronics to meet these objectives.
A 3D tomographic reconstruction method to analyze Jupiter's electron-belt emission observations
NASA Astrophysics Data System (ADS)
Santos-Costa, Daniel; Girard, Julien; Tasse, Cyril; Zarka, Philippe; Kita, Hajime; Tsuchiya, Fuminori; Misawa, Hiroaki; Clark, George; Bagenal, Fran; Imai, Masafumi; Becker, Heidi N.; Janssen, Michael A.; Bolton, Scott J.; Levin, Steve M.; Connerney, John E. P.
2017-04-01
Multi-dimensional reconstruction techniques of Jupiter's synchrotron radiation from radio-interferometric observations were first developed by Sault et al. [Astron. Astrophys., 324, 1190-1196, 1997]. The tomographic-like technique introduced 20 years ago had permitted the first 3-dimensional mapping of the brightness distribution around the planet. This technique has demonstrated the advantage to be weakly dependent on planetary field models. It also does not require any knowledge on the energy and spatial distributions of the radiating electrons. On the downside, it is assumed that the volume emissivity of any punctual point source around the planet is isotropic. This assumption becomes incorrect when mapping the brightness distribution for non-equatorial point sources or any point sources from Juno's perspective. In this paper, we present our modeling effort to bypass the isotropy issue. Our approach is to use radio-interferometric observations and determine the 3-D brightness distribution in a cylindrical coordinate system. For each set (z, r), we constrain the longitudinal distribution with a Fourier series and the anisotropy is addressed with a simple periodic function when possible. We develop this new method over a wide range of frequencies using past VLA and LOFAR observations of Jupiter. We plan to test this reconstruction method with observations of Jupiter that are currently being carried out with LOFAR and GMRT in support to the Juno mission. We describe how this new 3D tomographic reconstruction method provides new model constraints on the energy and spatial distributions of Jupiter's ultra-relativistic electrons close to the planet and be used to interpret Juno MWR observations of Jupiter's electron-belt emission and assist in evaluating the background noise from the radiation environment in the atmospheric measurements.
A Method for Identifying Contours in Processing Digital Images from Computer Tomograph
NASA Astrophysics Data System (ADS)
Roşu, Şerban; Pater, Flavius; Costea, Dan; Munteanu, Mihnea; Roşu, Doina; Fratila, Mihaela
2011-09-01
The first step in digital processing of two-dimensional computed tomography images is to identify the contour of component elements. This paper deals with the collective work of specialists in medicine and applied mathematics in computer science on elaborating new algorithms and methods in medical 2D and 3D imagery.
Tomographic digital subtraction angiography for lung perfusion estimation in rodents.
Badea, Cristian T; Hedlund, Laurence W; De Lin, Ming; Mackel, Julie S Boslego; Samei, Ehsan; Johnson, G Allan
2007-05-01
In vivo measurements of perfusion present a challenge to existing small animal imaging techniques such as magnetic resonance microscopy, micro computed tomography, micro positron emission tomography, and microSPECT, due to combined requirements for high spatial and temporal resolution. We demonstrate the use of tomographic digital subtraction angiography (TDSA) for estimation of perfusion in small animals. TDSA augments conventional digital subtraction angiography (DSA) by providing three-dimensional spatial information using tomosynthesis algorithms. TDSA is based on the novel paradigm that the same time density curves can be reproduced in a number of consecutive injections of microL volumes of contrast at a series of different angles of rotation. The capabilities of TDSA are established in studies on lung perfusion in rats. Using an imaging system developed in-house, we acquired data for four-dimensional (4D) imaging with temporal resolution of 140 ms, in-plane spatial resolution of 100 microm, and slice thickness on the order of millimeters. Based on a structured experimental approach, we optimized TDSA imaging providing a good trade-off between slice thickness, the number of injections, contrast to noise, and immunity to artifacts. Both DSA and TDSA images were used to create parametric maps of perfusion. TDSA imaging has potential application in a number of areas where functional perfusion measurements in 4D can provide valuable insight into animal models of disease and response to therapeutics.
Leblond, Guillaume; Gaitero, Luis; Moens, Noel M M; Zur Linden, Alex; James, Fiona M K; Monteith, Gabrielle J; Runciman, John
2017-11-01
Objectives Ventral atlantoaxial stabilization techniques are challenging surgical procedures in dogs. Available surgical guidelines are based upon subjective anatomical landmarks, and limited radiographic and computed tomographic data. The aims of this study were (1) to provide detailed anatomical descriptions of atlantoaxial optimal safe implantation corridors to generate objective recommendations for optimal implant placements and (2) to compare anatomical data obtained in non-affected Toy breed dogs, affected Toy breed dogs suffering from atlantoaxial instability and non-affected Beagle dogs. Methods Anatomical data were collected from a prospectively recruited population of 27 dogs using a previously validated method of optimal safe implantation corridor analysis using computed tomographic images. Results Optimal implant positions and three-dimensional numerical data were generated successfully in all cases. Anatomical landmarks could be used to generate objective definitions of optimal insertion points which were applicable across all three groups. Overall the geometrical distribution of all implant sites was similar in all three groups with a few exceptions. Clinical Significance This study provides extensive anatomical data available to facilitate surgical planning of implant placement for atlantoaxial stabilization. Our data suggest that non-affected Toy breed dogs and non-affected Beagle dogs constitute reasonable research models to study atlantoaxial stabilization constructs. Schattauer GmbH Stuttgart.
Carotid-bulb atypical fibromuscular dysplasia in young Afro-Caribbean patients with stroke.
Joux, Julien; Chausson, Nicolas; Jeannin, Séverine; Saint-Vil, Martine; Mejdoubi, Mehdi; Hennequin, Jean-Luc; Deschamps, Lydia; Smadja, Didier; Olindo, Stéphane
2014-12-01
An atypical form of fibromuscular dysplasia located in the internal carotid-bulb (CaFMD) is thought to be uncommon and is poorly described as a cause of ischemic stroke in the young. This study aimed to obtain a better description of CaFMD in Afro-Caribbean population, who could be particularly affected by it. This study included consecutive patients <55 years consulting at Fort-de-France University Hospital Stroke Center (Martinique, FWI) found to have CaFMD as the only cause after a comprehensive work-up. CaFMD was diagnosed when computed tomographic angiography showed a bulbar spur without calcification. Twenty-five patients with stroke and CaFMD were identified. Computed tomographic angiography showed 2 CaFMD patterns: a thin (n=15) or thick (n=10) spur. Three patients initial computed tomographic angiography images showed a mural thrombus overlying the CaFMD. CaFMD was surgically removed from 7 of 25 and 20 of 25 patients who received antiplatelet therapy; after mean follow-up of 25.3±19.5 months, their respective recurrence rates were 0% and 30%. CaFMD could be a common condition in young Afro-Caribbeans with carotid-territory ischemic stroke. Recurrences were frequent under antiplatelet treatment, while surgical CaFMD removal seemed more effective. © 2014 American Heart Association, Inc.
Effect of chronic right ventricular apical pacing on left ventricular function.
O'Keefe, James H; Abuissa, Hussam; Jones, Philip G; Thompson, Randall C; Bateman, Timothy M; McGhie, A Iain; Ramza, Brian M; Steinhaus, David M
2005-03-15
The determinants of change in left ventricular (LV) ejection fraction (EF) over time in patients with impaired LV function at baseline have not been clearly established. Using a nuclear database to assess changes in LV function over time, we included patients with a baseline LVEF of 25% to 40% on a gated single-photon emission computed tomographic study at rest and only if second-gated photon emission computed tomography performed approximately 18 months after the initial study showed an improvement in LVEF at rest of > or =10 points or a decrease in LVEF at rest of > or =7 points. In all, 148 patients qualified for the EF increase group and 59 patients for the EF decrease group. LVEF on average increased from 33 +/- 4% to 51 +/- 8% in the EF increase group and decreased from 35 +/- 4% to 25 +/- 5% in the EF decrease group. The strongest multivariable predictor of improvement of LVEF was beta-blocker therapy (odds ratio 3.9, p = 0.002). The strongest independent predictor of LVEF decrease was the presence of a permanent right ventricular apical pacemaker (odds ratio 6.6, p = 0.002). Thus, this study identified beta-blocker therapy as the major independent predictor for improvement in LVEF of > or =10 points, whereas a permanent pacemaker (right ventricular apical pacing) was the strongest predictor of a LVEF decrease of > or =7 points.
NASA Astrophysics Data System (ADS)
Lanen, Theo A.; Watt, David W.
1995-10-01
Singular value decomposition has served as a diagnostic tool in optical computed tomography by using its capability to provide insight into the condition of ill-posed inverse problems. Various tomographic geometries are compared to one another through the singular value spectrum of their weight matrices. The number of significant singular values in the singular value spectrum of a weight matrix is a quantitative measure of the condition of the system of linear equations defined by a tomographic geometery. The analysis involves variation of the following five parameters, characterizing a tomographic geometry: 1) the spatial resolution of the reconstruction domain, 2) the number of views, 3) the number of projection rays per view, 4) the total observation angle spanned by the views, and 5) the selected basis function. Five local basis functions are considered: the square pulse, the triangle, the cubic B-spline, the Hanning window, and the Gaussian distribution. Also items like the presence of noise in the views, the coding accuracy of the weight matrix, as well as the accuracy of the accuracy of the singular value decomposition procedure itself are assessed.
Tomographic inversion of satellite photometry
NASA Technical Reports Server (NTRS)
Solomon, S. C.; Hays, P. B.; Abreu, V. J.
1984-01-01
An inversion algorithm capable of reconstructing the volume emission rate of thermospheric airglow features from satellite photometry has been developed. The accuracy and resolution of this technique are investigated using simulated data, and the inversions of several sets of observations taken by the Visible Airglow Experiment are presented.
ERIC Educational Resources Information Center
Damasio, Antonio R., Damasio, Hanna
1992-01-01
Discusses the advances made in understanding the brain structures responsible for language. Presents findings made using magnetic resonance imaging (MRI) and positron emission tomographic (PET) scans to study brain activity. These findings map the structures in the brain that manipulate concepts and those that turn concepts into words. (MCO)
Banzato, Tommaso; Selleri, Paolo; Veladiano, Irene A; Martin, Andrea; Zanetti, Emanuele; Zotti, Alessandro
2012-05-11
Radiology and computed tomography are the most commonly available diagnostic tools for the diagnosis of pathologies affecting the head and skull in veterinary practice. Nevertheless, accurate interpretation of radiographic and CT studies requires a thorough knowledge of the gross and the cross-sectional anatomy. Despite the increasing success of reptiles as pets, only a few reports over their normal imaging features are currently available. The aim of this study is to describe the normal cadaveric, radiographic and computed tomographic features of the heads of the green iguana, tegu and bearded dragon. 6 adult green iguanas, 4 tegus, 3 bearded dragons, and, the adult cadavers of: 4 green iguana, 4 tegu, 4 bearded dragon were included in the study. 2 cadavers were dissected following a stratigraphic approach and 2 cadavers were cross-sectioned for each species. These latter specimens were stored in a freezer (-20°C) until completely frozen. Transversal sections at 5 mm intervals were obtained by means of an electric band-saw. Each section was cleaned and photographed on both sides. Radiographs of the head of each subject were obtained. Pre- and post- contrast computed tomographic studies of the head were performed on all the live animals. CT images were displayed in both bone and soft tissue windows. Individual anatomic structures were first recognised and labelled on the anatomic images and then matched on radiographs and CT images. Radiographic and CT images of the skull provided good detail of the bony structures in all species. In CT contrast medium injection enabled good detail of the soft tissues to be obtained in the iguana whereas only the eye was clearly distinguishable from the remaining soft tissues in both the tegu and the bearded dragon. The results provide an atlas of the normal anatomical and in vivo radiographic and computed tomographic features of the heads of lizards, and this may be useful in interpreting any imaging modality involving these species.
2012-01-01
Background Radiology and computed tomography are the most commonly available diagnostic tools for the diagnosis of pathologies affecting the head and skull in veterinary practice. Nevertheless, accurate interpretation of radiographic and CT studies requires a thorough knowledge of the gross and the cross-sectional anatomy. Despite the increasing success of reptiles as pets, only a few reports over their normal imaging features are currently available. The aim of this study is to describe the normal cadaveric, radiographic and computed tomographic features of the heads of the green iguana, tegu and bearded dragon. Results 6 adult green iguanas, 4 tegus, 3 bearded dragons, and, the adult cadavers of : 4 green iguana, 4 tegu, 4 bearded dragon were included in the study. 2 cadavers were dissected following a stratigraphic approach and 2 cadavers were cross-sectioned for each species. These latter specimens were stored in a freezer (−20°C) until completely frozen. Transversal sections at 5 mm intervals were obtained by means of an electric band-saw. Each section was cleaned and photographed on both sides. Radiographs of the head of each subject were obtained. Pre- and post- contrast computed tomographic studies of the head were performed on all the live animals. CT images were displayed in both bone and soft tissue windows. Individual anatomic structures were first recognised and labelled on the anatomic images and then matched on radiographs and CT images. Radiographic and CT images of the skull provided good detail of the bony structures in all species. In CT contrast medium injection enabled good detail of the soft tissues to be obtained in the iguana whereas only the eye was clearly distinguishable from the remaining soft tissues in both the tegu and the bearded dragon. Conclusions The results provide an atlas of the normal anatomical and in vivo radiographic and computed tomographic features of the heads of lizards, and this may be useful in interpreting any imaging modality involving these species. PMID:22578088
Sousa, Thiago Oliveira; Haiter-Neto, Francisco; Nascimento, Eduarda Helena Leandro; Peroni, Leonardo Vieira; Freitas, Deborah Queiroz; Hassan, Bassam
2017-07-01
The aim of this study was to assess the diagnostic accuracy of periapical radiography (PR) and cone-beam computed tomographic (CBCT) imaging in the detection of the root canal configuration (RCC) of human premolars. PR and CBCT imaging of 114 extracted human premolars were evaluated by 2 oral radiologists. RCC was recorded according to Vertucci's classification. Micro-computed tomographic imaging served as the gold standard to determine RCC. Accuracy, sensitivity, specificity, and predictive values were calculated. The Friedman test compared both PR and CBCT imaging with the gold standard. CBCT imaging showed higher values for all diagnostic tests compared with PR. Accuracy was 0.55 and 0.89 for PR and CBCT imaging, respectively. There was no difference between CBCT imaging and the gold standard, whereas PR differed from both CBCT and micro-computed tomographic imaging (P < .0001). CBCT imaging was more accurate than PR for evaluating different types of RCC individually. Canal configuration types III, VII, and "other" were poorly identified on CBCT imaging with a detection accuracy of 50%, 0%, and 43%, respectively. With PR, all canal configurations except type I were poorly visible. PR presented low performance in the detection of RCC in premolars, whereas CBCT imaging showed no difference compared with the gold standard. Canals with complex configurations were less identifiable using both imaging methods, especially PR. Copyright © 2017 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Computed Tomography Angiography in Microsurgery: Indications, Clinical Utility, and Pitfalls
Lee, Gordon K.; Fox, Paige M.; Riboh, Jonathan; Hsu, Charles; Saber, Sepideh; Rubin, Geoffrey D.; Chang, James
2013-01-01
Objective: Computed tomographic angiography (CTA) can be used to obtain 3-dimensional vascular images and soft-tissue definition. The goal of this study was to evaluate the reliability, usefulness, and pitfalls of CTA in preoperative planning of microvascular reconstructive surgery. Methods: A retrospective review of patients who obtained preoperative CTA in preparation for planned microvascular reconstruction was performed over a 5-year period (2001–2005). The influence of CTA on the original operative plan was assessed for each patient, and CTA results were correlated to the operative findings. Results: Computed tomographic angiography was performed on 94 patients in preparation for microvascular reconstruction. In 48 patients (51%), vascular abnormalities were noted on CTA. Intraoperative findings correlated with CTA results in 97% of cases. In 42 patients (45%), abnormal CTA findings influenced the original operative plan, such as the choice of vessels, side of harvest, or nature of the reconstruction (local flap instead of free tissue transfer). Technical difficulties in performing CTA were encountered in 5 patients (5%) in whom interference from external fixation devices was the main cause. Conclusions: This large study of CTA obtained for preoperative planning of reconstructive microsurgery at both donor and recipient sites study demonstrates that CTA is safe and highly accurate. Computed tomographic angiography can alter the surgeon's reconstructive plan when abnormalities are noted preoperatively and consequently improve results by decreasing vascular complication rates. The use of CTA should be considered for cases of microsurgical reconstruction where the vascular anatomy may be questionable. PMID:24023972
A PC-controlled microwave tomographic scanner for breast imaging
NASA Astrophysics Data System (ADS)
Padhi, Shantanu; Howard, John; Fhager, A.; Bengtsson, Sebastian
2011-01-01
This article presents the design and development of a personal computer based controller for a microwave tomographic system for breast cancer detection. The system uses motorized, dual-polarized antennas and a custom-made GUI interface to control stepper motors, a wideband vector network analyzer (VNA) and to coordinate data acquisition and archival in a local MDSPlus database. Both copolar and cross-polar scattered field components can be measured directly. Experimental results are presented to validate the various functionalities of the scanner.
3D electron tomography of pretreated biomass informs atomic modeling of cellulose microfibrils.
Ciesielski, Peter N; Matthews, James F; Tucker, Melvin P; Beckham, Gregg T; Crowley, Michael F; Himmel, Michael E; Donohoe, Bryon S
2013-09-24
Fundamental insights into the macromolecular architecture of plant cell walls will elucidate new structure-property relationships and facilitate optimization of catalytic processes that produce fuels and chemicals from biomass. Here we introduce computational methodology to extract nanoscale geometry of cellulose microfibrils within thermochemically treated biomass directly from electron tomographic data sets. We quantitatively compare the cell wall nanostructure in corn stover following two leading pretreatment strategies: dilute acid with iron sulfate co-catalyst and ammonia fiber expansion (AFEX). Computational analysis of the tomographic data is used to extract mathematical descriptions for longitudinal axes of cellulose microfibrils from which we calculate their nanoscale curvature. These nanostructural measurements are used to inform the construction of atomistic models that exhibit features of cellulose within real, process-relevant biomass. By computational evaluation of these atomic models, we propose relationships between the crystal structure of cellulose Iβ and the nanoscale geometry of cellulose microfibrils.
NASA Astrophysics Data System (ADS)
de Oliveira, José Martins, Jr.; Mangini, F. Salvador; Carvalho Vila, Marta Maria Duarte; ViníciusChaud, Marco
2013-05-01
This work presents an alternative and non-conventional technique for evaluatingof physic-chemical properties of pharmaceutical dosage forms, i.e. we used computed tomography (CT) technique as a nondestructive technique to visualize internal structures of pharmaceuticals dosage forms and to conduct static and dynamical studies. The studies were conducted involving static and dynamic situations through the use of tomographic images, generated by the scanner at University of Sorocaba - Uniso. We have shown that through the use of tomographic images it is possible to conduct studies of porosity, densities, analysis of morphological parameters and performing studies of dissolution. Our results are in agreement with the literature, showing that CT is a powerful tool for use in the pharmaceutical sciences.
Polf, Holly D; Smith, Shasta; Simpson, Katharine M; Rochat, Mark C
2015-01-01
To report diagnosis and treatment of urinary incontinence in a female Huacaya alpaca. Clinical case report. Female intact Huacaya alpaca (n = 1) METHODS: Computed tomographic (CT) excretory urography and vaginourethrography were performed to diagnose the cause of urinary incontinence. Bilateral ectopic ureters and left hydronephrosis and hydroureter were diagnosed. Left nephroureterectomy and right ureteroneocystostomy were performed with subsequent resolution of clinical signs. Pyelonephritis was identified by culture of the resected left kidney. CT excretory urography was helpful in the diagnosis of bilateral ectopic ureters in an alpaca and provided information for surgical planning. Surgical repair by ureteroneocystostomy and unilateral nephroureterectomy was successful in resolving clinical signs. © Copyright 2014 by The American College of Veterinary Surgeons.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pearlberg, J.L.; Sandler, M.A.; Kvale, P.
1985-03-01
Laser therapy is a new modality for treatment of airway lesions. The authors examined 18 patients prior to laser photoresection of tracheobronchial lesions. Thirteen had cancers involving the distal trachea, carina, and/or proximal bronchi; five had benign lesions of the middle or proximal trachea. Each patient was examined by conventional linear tomography (CLT) and computed tomography (CT). CT was valuable in patients who had lesions of the distal trachea, carina, and/or proximal bronchi. Its particular usefulness, and its advantage relative to CLT, consisted in its ability to delineate vascular structures adjacent to the planned area of photoresection. Neither CLT normore » CT was helpful in evaluation of benign lesions of the proximal trachea.« less
21 CFR 212.1 - What are the meanings of the technical terms used in these regulations?
Code of Federal Regulations, 2014 CFR
2014-04-01
..., numbers, or symbols from which the complete history of the production, processing, packing, holding, and... is used for providing dual photon positron emission tomographic diagnostic images. The definition.... Production means the manufacturing, compounding, processing, packaging, labeling, reprocessing, repacking...
21 CFR 212.1 - What are the meanings of the technical terms used in these regulations?
Code of Federal Regulations, 2012 CFR
2012-04-01
..., numbers, or symbols from which the complete history of the production, processing, packing, holding, and... is used for providing dual photon positron emission tomographic diagnostic images. The definition.... Production means the manufacturing, compounding, processing, packaging, labeling, reprocessing, repacking...
21 CFR 212.1 - What are the meanings of the technical terms used in these regulations?
Code of Federal Regulations, 2013 CFR
2013-04-01
..., numbers, or symbols from which the complete history of the production, processing, packing, holding, and... is used for providing dual photon positron emission tomographic diagnostic images. The definition.... Production means the manufacturing, compounding, processing, packaging, labeling, reprocessing, repacking...
NASA Astrophysics Data System (ADS)
Postpischl, L.; Morelli, A.; Danecek, P.
2009-04-01
Formats used to represent (and distribute) tomographic earth models differ considerably and are rarely self-consistent. In fact, each earth scientist, or research group, uses specific conventions to encode the various parameterizations used to describe, e.g., seismic wave speed or density in three dimensions, and complete information is often found in related documents or publications (if available at all) only. As a consequence, use of various tomographic models from different authors requires considerable effort, is more cumbersome than it should be and prevents widespread exchange and circulation within the community. We propose a format, based on modern web standards, able to represent different (grid-based) model parameterizations within the same simple text-based environment, easy to write, to parse, and to visualise. The aim is the creation of self-describing data-structures, both human and machine readable, that are automatically recognised by general-purpose software agents, and easily imported in the scientific programming environment. We think that the adoption of such a representation as a standard for the exchange and distribution of earth models can greatly ease their usage and enhance their circulation, both among fellow seismologists and among a broader non-specialist community. The proposed solution uses semantic web technologies, fully fitting the current trends in data accessibility. It is based on Json (JavaScript Object Notation), a plain-text, human-readable lightweight computer data interchange format, which adopts a hierarchical name-value model for representing simple data structures and associative arrays (called objects). Our implementation allows integration of large datasets with metadata (authors, affiliations, bibliographic references, units of measure etc.) into a single resource. It is equally suited to represent other geo-referenced volumetric quantities — beyond tomographic models — as well as (structured and unstructured) computational meshes. This approach can exploit the capabilities of the web browser as a computing platform: a series of in-page quick tools for comparative analysis between models will be presented, as well as visualisation techniques for tomographic layers in Google Maps and Google Earth. We are working on tools for conversion into common scientific format like netCDF, to allow easy visualisation in GEON-IDV or gmt.
Downscaling Smooth Tomographic Models: Separating Intrinsic and Apparent Anisotropy
NASA Astrophysics Data System (ADS)
Bodin, Thomas; Capdeville, Yann; Romanowicz, Barbara
2016-04-01
In recent years, a number of tomographic models based on full waveform inversion have been published. Due to computational constraints, the fitted waveforms are low pass filtered, which results in an inability to map features smaller than half the shortest wavelength. However, these tomographic images are not a simple spatial average of the true model, but rather an effective, apparent, or equivalent model that provides a similar 'long-wave' data fit. For example, it can be shown that a series of horizontal isotropic layers will be seen by a 'long wave' as a smooth anisotropic medium. In this way, the observed anisotropy in tomographic models is a combination of intrinsic anisotropy produced by lattice-preferred orientation (LPO) of minerals, and apparent anisotropy resulting from the incapacity of mapping discontinuities. Interpretations of observed anisotropy (e.g. in terms of mantle flow) requires therefore the separation of its intrinsic and apparent components. The "up-scaling" relations that link elastic properties of a rapidly varying medium to elastic properties of the effective medium as seen by long waves are strongly non-linear and their inverse highly non-unique. That is, a smooth homogenized effective model is equivalent to a large number of models with discontinuities. In the 1D case, Capdeville et al (GJI, 2013) recently showed that a tomographic model which results from the inversion of low pass filtered waveforms is an homogenized model, i.e. the same as the model computed by upscaling the true model. Here we propose a stochastic method to sample the ensemble of layered models equivalent to a given tomographic profile. We use a transdimensional formulation where the number of layers is variable. Furthermore, each layer may be either isotropic (1 parameter) or intrinsically anisotropic (2 parameters). The parsimonious character of the Bayesian inversion gives preference to models with the least number of parameters (i.e. least number of layers, and maximum number of isotropic layers). The non-uniqueness of the problem can be addressed by adding high frequency data such as receiver functions, able to map first order discontinuities. We show with synthetic tests that this method enables us to distinguish between intrinsic and apparent anisotropy in tomographic models, as layers with intrinsic anisotropy are only present when required by the data. A real data example is presented based on the latest global model produced at Berkeley.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kuhl, D.E.; Phelps, M.E.; Engel, J. Jr.
1980-01-01
The ECAT Positron Tomograph was used to scan normal control subjects, stroke patients at various times during recovery, and patients with partial epilepsy during EEG monitoring. /sup 18/F-fluorodeoxyglucose (/sup 18/FDG) and /sup 13/N-Ammonia (/sup 13/NH/sub 3/) were used as indicators of abnormalities in local cerebral glucose utilization (LCMR/sub glc/) and relative perfusion, respectively. Hypometabolism, due to deactivation or minimal damage, was demonstrated with the /sup 18/FDG scan in deep structures and broad zones of cerebral cortex which appeared normal on x-ray CT (XCT) and /sup 99m/Tc pertechnetate scans. In patients with partial epilepsy, who had unilateral or focal electrical abnormalities,more » interictal /sup 18/FDG scan patterns clearly showed localized regions of decreased (20 to 50%) LCMR/sub glc/, which correlated anatomically with the eventual EEG localization.« less
A fast multi-resolution approach to tomographic PIV
NASA Astrophysics Data System (ADS)
Discetti, Stefano; Astarita, Tommaso
2012-03-01
Tomographic particle image velocimetry (Tomo-PIV) is a recently developed three-component, three-dimensional anemometric non-intrusive measurement technique, based on an optical tomographic reconstruction applied to simultaneously recorded images of the distribution of light intensity scattered by seeding particles immersed into the flow. Nowadays, the reconstruction process is carried out mainly by iterative algebraic reconstruction techniques, well suited to handle the problem of limited number of views, but computationally intensive and memory demanding. The adoption of the multiplicative algebraic reconstruction technique (MART) has become more and more accepted. In the present work, a novel multi-resolution approach is proposed, relying on the adoption of a coarser grid in the first step of the reconstruction to obtain a fast estimation of a reliable and accurate first guess. A performance assessment, carried out on three-dimensional computer-generated distributions of particles, shows a substantial acceleration of the reconstruction process for all the tested seeding densities with respect to the standard method based on 5 MART iterations; a relevant reduction in the memory storage is also achieved. Furthermore, a slight accuracy improvement is noticed. A modified version, improved by a multiplicative line of sight estimation of the first guess on the compressed configuration, is also tested, exhibiting a further remarkable decrease in both memory storage and computational effort, mostly at the lowest tested seeding densities, while retaining the same performances in terms of accuracy.
Aging of the midface bony elements: a three-dimensional computed tomographic study.
Shaw, Robert B; Kahn, David M
2007-02-01
The face loses volume as the soft-tissue structures age. In this study, the authors demonstrate how specific bony aspects of the face change with age in both men and women and what impact this may have on the techniques used in facial cosmetic surgery. Facial bone computed tomographic scans were obtained from 60 Caucasian patients (30 women and 30 men). The authors' study population consisted of 10 male and 10 female subjects in each of three age categories. Each computed tomographic scan underwent three-dimensional reconstruction with volume rendering, and the following measurements were obtained: glabellar angle (maximal prominence of glabella to nasofrontal suture), pyriform angle (nasal bone to lateral inferior pyriform aperture), and maxillary angle (superior to inferior maxilla at the articulation of the inferior maxillary wing and alveolar arch). The pyriform aperture area was also obtained. The t test was used to identify any trends between age groups. The glabellar and maxillary angle in both the male and female subjects showed a significant decrease with increasing age. The pyriform angle did not show a significant change between age groups for either sex. There was a significant increase in pyriform aperture area from the young to the middle age group for both sexes. These results suggest that the bony elements of the midface change dramatically with age and, coupled with soft-tissue changes, lead to the appearance of the aged face.
Rapid prototyping in aortic surgery.
Bangeas, Petros; Voulalas, Grigorios; Ktenidis, Kiriakos
2016-04-01
3D printing provides the sequential addition of material layers and, thus, the opportunity to print parts and components made of different materials with variable mechanical and physical properties. It helps us create 3D anatomical models for the better planning of surgical procedures when needed, since it can reveal any complex anatomical feature. Images of abdominal aortic aneurysms received by computed tomographic angiography were converted into 3D images using a Google SketchUp free software and saved in stereolithography format. Using a 3D printer (Makerbot), a model made of polylactic acid material (thermoplastic filament) was printed. A 3D model of an abdominal aorta aneurysm was created in 138 min, while the model was a precise copy of the aorta visualized in the computed tomographic images. The total cost (including the initial cost of the printer) reached 1303.00 euros. 3D imaging and modelling using different materials can be very useful in cases when anatomical difficulties are recognized through the computed tomographic images and a tactile approach is demanded preoperatively. In this way, major complications during abdominal aorta aneurysm management can be predicted and prevented. Furthermore, the model can be used as a mould; the development of new, more biocompatible, less antigenic and individualized can become a challenge in the future. © The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Can macrocirculation changes predict nonhealing diabetic foot ulcers?
Lee, Ye-Na; Kim, Hyon-Surk; Kang, Jeong-A; Han, Seung-Kyu
2014-01-01
Transcutaneous partial oxygen tension (TcpO2) is considered the gold standard for assessment of tissue oxygenation, which is an essential factor for wound healing. The purpose of this study was to evaluate the association between macrocirculation and TcpO2 in persons with diabetes mellitus. Ninety-eight patients with diabetic foot ulcers participated in the study (61 men and 37 women). The subjects had a mean age of 66.6 years (range, 30-83 years) and were treated at the Diabetic Wound Center of Korea University Guro Hospital, Seoul, Republic of Korea. Macrocirculation was evaluated using 2 techniques: computed tomographic angiography and Doppler ultrasound. Macrocirculation scores were based on the patency of the two tibial arteries in 98 patients. Computed tomographic angiography and Doppler ultrasound scores (0-4 points) were given according to intraluminal filling defects and arterial pulse waveform of each vessel, respectively. Tissue oxygenation was measured by TcpO2. Macrocirculation scores were statistically analyzed as a function of the TcpO2. Statistical analysis revealed no significant linear trend between the macrocirculation status and TcpO2. Biavariate analysis using the Fisher exact test, Mantel-Haenszel tests, and McNemar-Bowker tests also found no significant relationship between macrocirculation and TcpO2. Computed tomographic angiography and Doppler ultrasound are not sufficiently reliable substitutes for TcpO2 measurements in regard to determining the optimal treatment for diabetic patients.
Shin, M S; Zorn, G L; Ho, K J
1988-04-01
Computed tomographic (CT) findings of a rare case of triple-barreled aortic dissection was described. CT demonstrated the extent of dissection, a communication between two channels, and three lumens separated by the intimal flap and a thin undetached tunica media, resembling a Mercedes-Benz mark.
Lau, S F; Wolschrijn, C F; Hazewinkel, H A W; Siebelt, M; Voorhout, G
2013-09-01
Medial coronoid disease (MCD) encompasses lesions of the entire medial coronoid process (MCP), both of the articular cartilage and the subchondral bone. To detect the earliest signs of MCD, radiography and computed tomography were used to monitor the development of MCD in 14 Labrador retrievers, from 6 to 7 weeks of age until euthanasia. The definitive diagnosis of MCD was based on necropsy and micro-computed tomography findings. The frequency of MCD in the dogs studied was 50%. Radiographic findings did not provide evidence of MCD, ulnar subtrochlear sclerosis or blunting of the cranial edge of the MCP. Computed tomography was more sensitive (30.8%) than radiography (0%) in detecting early MCD, with the earliest signs detectable at 14 weeks of age. A combination of the necropsy and micro-computed tomography findings of the MCP showed that MCD was manifested as a lesion of only the subchondral bone in dogs <18 weeks of age. In all dogs (affected and unaffected), there was close contact between the base of the MCP and the proximal radial head in the congruent joints. Computed tomography and micro-computed tomography findings indicated that the lesions of MCD probably originated at the base of the MCP. Copyright © 2013 Elsevier Ltd. All rights reserved.
Computed tomographic and cross-sectional anatomy of the normal pacu (Colossoma macroponum).
Carr, Alaina; Weber, E P Scott; Murphy, Chris J; Zwingenberger, Alison
2014-03-01
The purpose of this study was to compare and define the normal cross-sectional gross and computed tomographic (CT) anatomy for a species of boney fish to better gain insight into the use of advanced diagnostic imaging for future clinical cases. The pacu (Colossoma macropomum) was used because of its widespread presence in the aquarium trade, its relatively large body size, and its importance in the research and aquaculture settings. Transverse 0.6-mm CT images of three cadaver fish were obtained and compared to corresponding frozen cross sections of the fish. Relevant anatomic structures were identified and labeled at each level; the Hounsfield unit density of major organs was established. The images presented good anatomic detail and provide a reference for future research and clinical investigation.
Lionberger, David R; Weise, Jennifer; Ho, David M; Haddad, John L
2008-06-01
Forty-six primary total knee arthroplasties were performed using either an electromagnetic (EM) or infrared (IR) navigation system. In this IRB-approved study, patients were evaluated clinically and for accuracy using spiral computed tomographic imaging and 36-in standing radiographs. Although EM navigation was subject to metal interference, it was not as drastic as line-of-sight interference with IR navigation. Mechanical alignment was ideal in 92.9% of EM and 90.0% of IR cases based on spiral computed tomographic imaging and 100% of EM and 95% of IR cases based on x-ray. Individual measurements of component varus/valgus and sagittal measurements showed EM to be equivalent to IR, with both systems producing subdegree accuracy in 95% of the readings.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tait, Paul; Waheed, Umeer; Bell, Suzanne, E-mail: drsuzy29@hotmail.co
2009-07-15
The insertion of a chest drain catheter for the management of a pneumothorax in an 82-year-old woman resulted in the unusual complication of liver penetration. The position of the drain was assessed by contrast-enhanced computed tomographic scan. Because the patient was hemodynamically stable and no damage to major vessels was seen on computed tomographic scan, the patient was treated in a nonoperative manner. A procedure was performed under controlled conditions using techniques used during transhepatic liver biopsies but with the addition of a balloon catheter. Embolization of the liver track was performed during chest drain removal. The drain was successfullymore » removed without the complication of bleeding in a patient unsuitable for a general anesthetic.« less
Chow, Kathleen Ella; Krockenberger, Mark; Collins, David
2016-01-01
A 15-year-old female spayed domestic long-haired cat was referred for trismus, hypersalivation, and bilateral ocular discharge. On examination, the cat showed pain on palpation of the left zygomatic arch, palpable crepitus of the frontal region, and limited retropulsion of both globes. A contrast-enhanced sinonasal computed tomographic study was performed, showing facial distortion and extensive osteolysis of the skull, extending beyond the confines of the sinonasal and paranasal cavities. Additionally, soft tissue and fluid accumulation were observed in the nasal cavities and paranasal sinuses. Postmortem biopsy samples acquired from the calvarium yielded a histologic diagnosis of sinonasal adenosquamous carcinoma, a rare and particularly aggressive neoplasm previously only reported in the esophagus of one cat. © 2015 American College of Veterinary Radiology.
NASA Astrophysics Data System (ADS)
Craciunescu, Teddy; Peluso, Emmanuele; Murari, Andrea; Gelfusa, Michela; JET Contributors
2018-05-01
The total emission of radiation is a crucial quantity to calculate the power balances and to understand the physics of any Tokamak. Bolometric systems are the main tool to measure this important physical quantity through quite sophisticated tomographic inversion methods. On the Joint European Torus, the coverage of the bolometric diagnostic, due to the availability of basically only two projection angles, is quite limited, rendering the inversion a very ill-posed mathematical problem. A new approach, based on the maximum likelihood, has therefore been developed and implemented to alleviate one of the major weaknesses of traditional tomographic techniques: the difficulty to determine routinely the confidence intervals in the results. The method has been validated by numerical simulations with phantoms to assess the quality of the results and to optimise the configuration of the parameters for the main types of emissivity encountered experimentally. The typical levels of statistical errors, which may significantly influence the quality of the reconstructions, have been identified. The systematic tests with phantoms indicate that the errors in the reconstructions are quite limited and their effect on the total radiated power remains well below 10%. A comparison with other approaches to the inversion and to the regularization has also been performed.
Efficient volumetric estimation from plenoptic data
NASA Astrophysics Data System (ADS)
Anglin, Paul; Reeves, Stanley J.; Thurow, Brian S.
2013-03-01
The commercial release of the Lytro camera, and greater availability of plenoptic imaging systems in general, have given the image processing community cost-effective tools for light-field imaging. While this data is most commonly used to generate planar images at arbitrary focal depths, reconstruction of volumetric fields is also possible. Similarly, deconvolution is a technique that is conventionally used in planar image reconstruction, or deblurring, algorithms. However, when leveraged with the ability of a light-field camera to quickly reproduce multiple focal planes within an imaged volume, deconvolution offers a computationally efficient method of volumetric reconstruction. Related research has shown than light-field imaging systems in conjunction with tomographic reconstruction techniques are also capable of estimating the imaged volume and have been successfully applied to particle image velocimetry (PIV). However, while tomographic volumetric estimation through algorithms such as multiplicative algebraic reconstruction techniques (MART) have proven to be highly accurate, they are computationally intensive. In this paper, the reconstruction problem is shown to be solvable by deconvolution. Deconvolution offers significant improvement in computational efficiency through the use of fast Fourier transforms (FFTs) when compared to other tomographic methods. This work describes a deconvolution algorithm designed to reconstruct a 3-D particle field from simulated plenoptic data. A 3-D extension of existing 2-D FFT-based refocusing techniques is presented to further improve efficiency when computing object focal stacks and system point spread functions (PSF). Reconstruction artifacts are identified; their underlying source and methods of mitigation are explored where possible, and reconstructions of simulated particle fields are provided.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ballard, Sanford; Hipp, James R.; Begnaud, Michael L.
The task of monitoring the Earth for nuclear explosions relies heavily on seismic data to detect, locate, and characterize suspected nuclear tests. In this study, motivated by the need to locate suspected explosions as accurately and precisely as possible, we developed a tomographic model of the compressional wave slowness in the Earth’s mantle with primary focus on the accuracy and precision of travel-time predictions for P and Pn ray paths through the model. Path-dependent travel-time prediction uncertainties are obtained by computing the full 3D model covariance matrix and then integrating slowness variance and covariance along ray paths from source tomore » receiver. Path-dependent travel-time prediction uncertainties reflect the amount of seismic data that was used in tomography with very low values for paths represented by abundant data in the tomographic data set and very high values for paths through portions of the model that were poorly sampled by the tomography data set. The pattern of travel-time prediction uncertainty is a direct result of the off-diagonal terms of the model covariance matrix and underscores the importance of incorporating the full model covariance matrix in the determination of travel-time prediction uncertainty. In addition, the computed pattern of uncertainty differs significantly from that of 1D distance-dependent travel-time uncertainties computed using traditional methods, which are only appropriate for use with travel times computed through 1D velocity models.« less
Ballard, Sanford; Hipp, James R.; Begnaud, Michael L.; ...
2016-10-11
The task of monitoring the Earth for nuclear explosions relies heavily on seismic data to detect, locate, and characterize suspected nuclear tests. In this study, motivated by the need to locate suspected explosions as accurately and precisely as possible, we developed a tomographic model of the compressional wave slowness in the Earth’s mantle with primary focus on the accuracy and precision of travel-time predictions for P and Pn ray paths through the model. Path-dependent travel-time prediction uncertainties are obtained by computing the full 3D model covariance matrix and then integrating slowness variance and covariance along ray paths from source tomore » receiver. Path-dependent travel-time prediction uncertainties reflect the amount of seismic data that was used in tomography with very low values for paths represented by abundant data in the tomographic data set and very high values for paths through portions of the model that were poorly sampled by the tomography data set. The pattern of travel-time prediction uncertainty is a direct result of the off-diagonal terms of the model covariance matrix and underscores the importance of incorporating the full model covariance matrix in the determination of travel-time prediction uncertainty. In addition, the computed pattern of uncertainty differs significantly from that of 1D distance-dependent travel-time uncertainties computed using traditional methods, which are only appropriate for use with travel times computed through 1D velocity models.« less
Toward regional-scale adjoint tomography in the deep earth
NASA Astrophysics Data System (ADS)
Masson, Y.; Romanowicz, B. A.
2013-12-01
Thanks to the development of efficient numerical computation methods, such as the Spectral Element Method (SEM) and to the increasing power of computer clusters, it is now possible to obtain regional-scale images of the Earth's interior using adjoint-tomography (e.g. Tape, C., et al., 2009). As for now, these tomographic models are limited to the upper layers of the earth, i.e., they provide us with high-resolution images of the crust and the upper part of the mantle. Given the gigantic amount of calculation it represents, obtaing similar models at the global scale (i.e. images of the entire Earth) seems out of reach at the moment. Furthermore, it's likely that the first generation of such global adjoint tomographic models will have a resolution significantly smaller than the current regional models. In order to image regions of interests in the deep Earth, such as plumes, slabs or large low shear velocity provinces (LLSVPs), while keeping the computation tractable, we are developing new tools that will allow us to perform regional-scale adjoint-tomography at arbitrary depths. In a recent study (Masson et al., 2013), we showed that a numerical equivalent of the time reversal mirrors used in experimental acoustics permits to confine the wave propagation computations (i.e. using SEM simulations) inside the region to be imaged. With this ability to limit wave propagation modeling inside a region of interest, obtaining the adjoint sensitivity kernels needed for tomographic imaging is only two steps further. First, the local wavefield modeling needs to be coupled with field extrapolation techniques in order to obtain synthetic seismograms at the surface of the earth. These seismograms will account for the 3D structure inside the region of interest in a quasi-exact manner. We will present preliminary results where the field-extrapolation is performed using Green's function computed in a 1D Earth model thanks to the Direct Solution Method (DSM). Once synthetic seismograms can be obtained, it is possible to evaluate the misfit between observed and computed seismograms. The second step will then be to extrapolate the misfit function back into the SEM region in order to compute local adjoint sensitivity kernels. When available, these kernels will allow us to perform regional-scale adjoint tomography at arbitrary locations inside the earth. Masson Y., Cupillard P., Capdeville Y., & Romanowicz B., 2013. On the numerical implementation of time-reversal mirrors for tomographic imaging, Journal of Geophysical Research (under review). Tape, C., et al. (2009). "Adjoint tomography of the southern California crust." Science 325(5943): 988-992.
Tomographic assessment of the spine in children with spondylocostal dysotosis syndrome.
Kaissi, Ali Al; Klaushofer, Klaus; Grill, Franz
2010-01-01
The aim of this study was to perform a detailed tomographic analysis of the skull base, craniocervical junction, and the entire spine in seven patients with spondylocostal dysostosis syndrome. Detailed scanning images have been organized in accordance with the most prominent clinical pathology. The reasons behind plagiocephaly, torticollis, short immobile neck, scoliosis and rigid back have been detected. Radiographic documentation was insufficient modality. Detailed computed tomography scans provided excellent delineation of the osseous abnormality pattern in our patients. This article throws light on the most serious osseous manifestations of spondylocostal dysostosissyndrome.
2012-01-01
Background In pigs, diseases of the respiratory tract like pleuropneumonia due to Actinobacillus pleuropneumoniae (App) infection have led to high economic losses for decades. Further research on disease pathogenesis, pathogen-host-interactions and new prophylactic and therapeutic approaches are needed. In most studies, a large number of experimental animals are required to assess lung alterations at different stages of the disease. In order to reduce the required number of animals but nevertheless gather information on the nature and extent of lung alterations in living pigs, a computed tomographic scoring system for quantifying gross pathological findings was developed. In this study, five healthy pigs served as control animals while 24 pigs were infected with App, the causative agent of pleuropneumonia in pigs, in an established model for respiratory tract disease. Results Computed tomographic (CT) findings during the course of App challenge were verified by radiological imaging, clinical, serological, gross pathology and histological examinations. Findings from clinical examinations and both CT and radiological imaging, were recorded on day 7 and day 21 after challenge. Clinical signs after experimental App challenge were indicative of acute to chronic disease. Lung CT findings of infected pigs comprised ground-glass opacities and consolidation. On day 7 and 21 the clinical scores significantly correlated with the scores of both imaging techniques. At day 21, significant correlations were found between clinical scores, CT scores and lung lesion scores. In 19 out of 22 challenged pigs the determined disease grades (not affected, slightly affected, moderately affected, severely affected) from CT and gross pathological examination were in accordance. Disease classification by radiography and gross pathology agreed in 11 out of 24 pigs. Conclusions High-resolution, high-contrast CT examination with no overlapping of organs is superior to radiography in the assessment of pneumonic lung lesions after App challenge. The new CT scoring system allows for quantification of gross pathological lung alterations in living pigs. However, computed tomographic findings are not informative of the etiology of respiratory disease. PMID:22546414
[Multispiral computed tomographic semiotics of laryngeal cancer].
Vasil'ev, P V; Iudin, A L; Sdvizhkov, A M; Kozhanov, L G
2007-01-01
Multispiral computed tomography (MSCT) with intravenous bolus contrasting is a currently available method for radiodiagnosis of laryngeal cancer. MSCT is of much higher informative value in estimating the extent of a tumorous lesion than the traditional radiodiagnostic techniques: linear tomography, lateral X-ray study, roentgenoscopy and roentgenography of the laryngopharynx and esophagus with barium meal.
Soil structure characterized using computed tomographic images
Zhanqi Cheng; Stephen H. Anderson; Clark J. Gantzer; J. W. Van Sambeek
2003-01-01
Fractal analysis of soil structure is a relatively new method for quantifying the effects of management systems on soil properties and quality. The objective of this work was to explore several methods of studying images to describe and quantify structure of soils under forest management. This research uses computed tomography and a topological method called Multiple...
NASA Astrophysics Data System (ADS)
Cha, Don J.; Cha, Soyoung S.
1995-09-01
A computational tomographic technique, termed the variable grid method (VGM), has been developed for improving interferometric reconstruction of flow fields under ill-posed data conditions of restricted scanning and incomplete projection. The technique is based on natural pixel decomposition, that is, division of a field into variable grid elements. The performances of two algorithms, that is, original and revised versions, are compared to investigate the effects of the data redundancy criteria and seed element forming schemes. Tests of the VGMs are conducted through computer simulation of experiments and reconstruction of fields with a limited view angel of 90 degree(s). The temperature fields at two horizontal sections of a thermal plume of two interacting isothermal cubes, produced by a finite numerical code, are analyzed as test fields. The computer simulation demonstrates the superiority of the revised VGM to either the conventional fixed grid method or the original VGM. Both the maximum and average reconstruction errors are reduced appreciably. The reconstruction shows substantial improvement in the regions with dense scanning by probing rays. These regions are usually of interest in engineering applications.
J-PET: A New Technology for the Whole-body PET Imaging
NASA Astrophysics Data System (ADS)
Niedźwiecki, S.; Białas, P.; Curceanu, C.; Czerwiński, E.; Dulski, K.; Gajos, A.; Głowacz, B.; Gorgol, M.; Hiesmayr, B. C.; Jasińska, B.; Kapłon, Ł.; Kisielewska-Kamińska, D.; Korcyl, G.; Kowalski, P.; Kozik, T.; Krawczyk, N.; Krzemień, W.; Kubicz, E.; Mohammed, M.; Pawlik-Niedźwiecka, M.; Pałka, M.; Raczyński, L.; Rudy, Z.; Sharma, N. G.; Sharma, S.; Shopa, R. Y.; Silarski, M.; Skurzok, M.; Wieczorek, A.; Wiślicki, W.; Zgardzińska, B.; Zieliński, M.; Moskal, P.
The Jagiellonian Positron Emission Tomograph (J-PET) is the first PET built from plastic scintillators. J-PET prototype consists of 192 detection modules arranged axially in three layers forming a cylindrical diagnostic chamber with the inner diameter of 85 cm and the axial field-of-view of 50 cm. An axial arrangement of long strips of plastic scintillators, their small light attenuation, superior timing properties, and relative ease of the increase of the axial field-of-view opens promising perspectives for the cost effective construction of the whole-body PET scanner, as well as construction of MR and CT compatible PET inserts. Present status of the development of the J-PET tomograph will be presented and discussed.
Kotasidis, F A; Mehranian, A; Zaidi, H
2016-05-07
Kinetic parameter estimation in dynamic PET suffers from reduced accuracy and precision when parametric maps are estimated using kinetic modelling following image reconstruction of the dynamic data. Direct approaches to parameter estimation attempt to directly estimate the kinetic parameters from the measured dynamic data within a unified framework. Such image reconstruction methods have been shown to generate parametric maps of improved precision and accuracy in dynamic PET. However, due to the interleaving between the tomographic and kinetic modelling steps, any tomographic or kinetic modelling errors in certain regions or frames, tend to spatially or temporally propagate. This results in biased kinetic parameters and thus limits the benefits of such direct methods. Kinetic modelling errors originate from the inability to construct a common single kinetic model for the entire field-of-view, and such errors in erroneously modelled regions could spatially propagate. Adaptive models have been used within 4D image reconstruction to mitigate the problem, though they are complex and difficult to optimize. Tomographic errors in dynamic imaging on the other hand, can originate from involuntary patient motion between dynamic frames, as well as from emission/transmission mismatch. Motion correction schemes can be used, however, if residual errors exist or motion correction is not included in the study protocol, errors in the affected dynamic frames could potentially propagate either temporally, to other frames during the kinetic modelling step or spatially, during the tomographic step. In this work, we demonstrate a new strategy to minimize such error propagation in direct 4D image reconstruction, focusing on the tomographic step rather than the kinetic modelling step, by incorporating time-of-flight (TOF) within a direct 4D reconstruction framework. Using ever improving TOF resolutions (580 ps, 440 ps, 300 ps and 160 ps), we demonstrate that direct 4D TOF image reconstruction can substantially prevent kinetic parameter error propagation either from erroneous kinetic modelling, inter-frame motion or emission/transmission mismatch. Furthermore, we demonstrate the benefits of TOF in parameter estimation when conventional post-reconstruction (3D) methods are used and compare the potential improvements to direct 4D methods. Further improvements could possibly be achieved in the future by combining TOF direct 4D image reconstruction with adaptive kinetic models and inter-frame motion correction schemes.
NASA Astrophysics Data System (ADS)
Kotasidis, F. A.; Mehranian, A.; Zaidi, H.
2016-05-01
Kinetic parameter estimation in dynamic PET suffers from reduced accuracy and precision when parametric maps are estimated using kinetic modelling following image reconstruction of the dynamic data. Direct approaches to parameter estimation attempt to directly estimate the kinetic parameters from the measured dynamic data within a unified framework. Such image reconstruction methods have been shown to generate parametric maps of improved precision and accuracy in dynamic PET. However, due to the interleaving between the tomographic and kinetic modelling steps, any tomographic or kinetic modelling errors in certain regions or frames, tend to spatially or temporally propagate. This results in biased kinetic parameters and thus limits the benefits of such direct methods. Kinetic modelling errors originate from the inability to construct a common single kinetic model for the entire field-of-view, and such errors in erroneously modelled regions could spatially propagate. Adaptive models have been used within 4D image reconstruction to mitigate the problem, though they are complex and difficult to optimize. Tomographic errors in dynamic imaging on the other hand, can originate from involuntary patient motion between dynamic frames, as well as from emission/transmission mismatch. Motion correction schemes can be used, however, if residual errors exist or motion correction is not included in the study protocol, errors in the affected dynamic frames could potentially propagate either temporally, to other frames during the kinetic modelling step or spatially, during the tomographic step. In this work, we demonstrate a new strategy to minimize such error propagation in direct 4D image reconstruction, focusing on the tomographic step rather than the kinetic modelling step, by incorporating time-of-flight (TOF) within a direct 4D reconstruction framework. Using ever improving TOF resolutions (580 ps, 440 ps, 300 ps and 160 ps), we demonstrate that direct 4D TOF image reconstruction can substantially prevent kinetic parameter error propagation either from erroneous kinetic modelling, inter-frame motion or emission/transmission mismatch. Furthermore, we demonstrate the benefits of TOF in parameter estimation when conventional post-reconstruction (3D) methods are used and compare the potential improvements to direct 4D methods. Further improvements could possibly be achieved in the future by combining TOF direct 4D image reconstruction with adaptive kinetic models and inter-frame motion correction schemes.
Iliac screw fixation using computer-assisted computer tomographic image guidance: technical note.
Shin, John H; Hoh, Daniel J; Kalfas, Iain H
2012-03-01
Iliac screw fixation is a powerful tool used by spine surgeons to achieve fusion across the lumbosacral junction for a number of indications, including deformity, tumor, and pseudarthrosis. Complications associated with screw placement are related to blind trajectory selection and excessive soft tissue dissection. To describe the technique of iliac screw fixation using computed tomographic (CT)-based image guidance. Intraoperative registration and verification of anatomic landmarks are performed with the use of a preoperatively acquired CT of the lumbosacral spine. With the navigation probe, the ideal starting point for screw placement is selected while visualizing the intended trajectory and target on a computer screen. Once the starting point is selected and marked with a burr, a drill guide is docked within this point and the navigation probe re-inserted, confirming the trajectory. The probe is then removed and the high-speed drill reinserted within the drill guide. Drilling is performed to a depth measured on the computer screen and a screw is placed. Confirmation of accurate placement of iliac screws can be performed with standard radiographs. CT-guided navigation allows for 3-dimensional visualization of the pelvis and minimizes complications associated with soft-tissue dissection and breach of the ilium during screw placement.
Cantekin, Kenan; Sekerci, Ahmet Ercan; Buyuk, Suleyman Kutalmis
2013-12-01
Computed tomography (CT) is capable of providing accurate and measurable 3-dimensional images of the third molar. The aims of this study were to analyze the development of the mandibular third molar and its relation to chronological age and to create new reference data for a group of Turkish participants aged 9 to 25 years on the basis of cone-beam CT images. All data were obtained from the patients' records including medical, social, and dental anamnesis and cone-beam CT images of 752 patients. Linear regression analysis was performed to obtain regression formulas for dental age calculation with chronological age and to determine the coefficient of determination (r) for each sex. Statistical analysis showed a strong correlation between age and third-molar development for the males (r2 = 0.80) and the females (r2 = 0.78). Computed tomographic images are clinically useful for accurate and reliable estimation of dental ages of children and youth.
Casey, M B; Pearson, G R; Perkins, J D; Tremaine, W H
2015-09-01
The most prevalent type of equine dental pulpitis due to apical infection is not associated with coronal fractures or periodontal disease. The pathogenesis of this type of pulpitis is not fully understood. Computed tomography (CT) is increasingly used to investigate equine dental disorders. However, gross, tomographic and histopathological changes in equine dental pulpitis have not been compared previously. To compare gross, CT and histological appearances of sectioned mandibular cheek teeth extracted from horses with clinical signs of pulpitis without coronal fractures or periodontal disease. To contribute to understanding the pathogenesis of equine dental pulpitis. Descriptive study using diseased and healthy teeth. Mandibular cheek teeth extracted from horses with clinical signs of pulpitis (cases), and from cadavers with no history of dental disease (controls), were compared using CT in the transverse plane at 1 mm intervals. Teeth were then sectioned transversely, photographed and processed for histopathological examination. Tomographs were compared with corresponding gross and histological sections. Cement, dentine and bone had similar ranges of attenuation (550-2000 Hounsfield Units, HU) in tomographs but could be differentiated from pulp (-400 to 500 HU) and enamel (> 2500 HU). Twelve discrete dental lesions were identified grossly, 10 of which were characterised histologically. Reactive and reparative dentinogenesis and extensive pulpar mineralisation, previously undescribed, were identified. Pulpar oedema, neutrophilic inflammation, cement and enamel defects, and reactive cemental deposition were also observed. The CT and pathological findings corresponded well where there was mineralised tissue deposited, defects in mineralised tissue, or food material in the pulpar area. Pulpar and dentinal necrosis and cement destruction, evident grossly and histologically, did not correspond to CT changes. Computed tomography is useful for identifying deposition and defects of mineralised material but less useful for identifying inflammation and tissue destruction. The equine dentine-pulp complex responds to insult with reactive and reparative changes. © 2014 EVJ Ltd.
Computed tomographic features of canine nonparenchymal hemangiosarcoma.
Fukuda, Shoko; Kobayashi, Tetsuya; Robertson, Ian D; Oshima, Fukiko; Fukazawa, Eri; Nakano, Yuko; Ono, Shin; Thrall, Donald E
2014-01-01
The purpose of this retrospective study was to describe pre- and postcontrast computed tomographic (CT) characteristics of confirmed nonparenchymal hemangiosarcoma in a group of dogs. Medical records were searched during the period of July 2003 and October 2011 and dogs with histologically confirmed nonparenchymal hemangiosarcoma and pre- and postcontrast CT images were recruited. Two observers recorded a consensus opinion for the following CT characteristics for each dog: largest transverse tumor diameter, number of masses, general tumor shape, character of the tumor margin, precontrast appearance, presence of dystrophic calcification, presence of postcontrast enhancement, pattern of postcontrast enhancement, presence of regional lymphadenopathy, and presence of associated cavitary fluid. A total of 17 dogs met inclusion criteria. Tumors were located in the nasal cavity, muscle, mandible, mesentery, subcutaneous tissue, and retroperitoneal space. Computed tomographic features of nonparenchymal hemangiosarcoma were similar to those of other soft tissue sarcomas, with most tumors being heterogeneous in precontrast images, invasive into adjacent tissue, and heterogeneously contrast enhancing. One unexpected finding was the presence of intense foci of contrast enhancement in 13 of the 17 tumors (76%). This appearance, which is not typical of other soft tissue sarcomas, was consistent with contrast medium residing in vascular channels. Findings indicated that there were no unique distinguishing CT characteristics for nonparenchymal hemangiosarcoma in dogs; however, the presence of highly attenuating foci of contrast enhancement may warrant further investigation in prospective diagnostic sensitivity and treatment outcome studies. © 2014 American College of Veterinary Radiology.
de Almeida, Bernardo Corrêa; Ormiga, Fabíola; de Araújo, Marcos César Pimenta; Lopes, Ricardo Tadeu; Lima, Inayá Corrêa Barbosa; dos Santos, Bernardo Camargo; Gusman, Heloisa
2015-12-01
The aim of this study was to make a 3-dimensional comparison of the canal transportation and changes in apical geometry using micro-computed tomographic imaging after canal preparation with K3 (SybronEndo, Orange, CA) and K3XF (SybronEndo) file systems. Twenty-eight mandibular molars were randomly divided into 2 groups according to the rotary system used in instrumentation: K3 or K3XF. The specimens were scanned by micro-computed tomographic imaging before and after instrumentation. Images before and after instrumentation from each group were compared with regard to canal volume, surface area, and structure model index (SMI) (paired t test, P < .05). After instrumentation, the canals from each group were compared regarding the changes in volume, surface area, SMI, and canal transportation in the last 4 apical mm (t test, P < .05). Instrumentation with the 2 rotary systems significantly changed the canal volume, surface area, and SMI (P < .05). There were no significant differences between instrument types concerning these parameters (P > .05). There were no significant differences between the 2 groups with regard to canal transportation in the last 4 apical mm (P > .05). Both rotary systems showed adequate canal preparations with reduced values of canal transportation. Heat treatment did not influence changes in root canal geometry in the apical region. Copyright © 2015 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Hwang, Jeong-Hwa; Misumi, Shigeki; Sahin, Hakan; Brown, Kevin K; Newell, John D; Lynch, David A
2009-01-01
To compare the computed tomographic (CT) features of idiopathic fibrosing interstitial pneumonia with those of pulmonary fibrosis related to collagen vascular disease (CVD). We reviewed the CT scans of 177 patients with diffuse interstitial pulmonary fibrosis, of which 97 had idiopathic fibrosing interstitial pneumonia and 80 had CVD. The CT images were systematically scored for the presence and extent of pulmonary and extrapulmonary abnormalities. Computed tomographic diagnosis of usual interstitial pneumonia (UIP) or nonspecific interstitial pneumonia (NSIP) was assigned. A CT pattern of UIP was identified in 59 (60.8%) of patients with idiopathic fibrosing interstitial pneumonia compared with 15 (18.7%) of those patients with CVD; conversely, the CT diagnosis of NSIP was made in 51 (64%) of patients with CVD compared with 36 (37%) of patients with idiopathic disease (P < 0.01). In 113 patients who had lung biopsy, the CT diagnoses of UIP and NSIP were concordant with the histologic diagnoses in 36 of 50 patients and 34 of 41 patients, respectively. Pleural effusions, esophageal dilation, and pericardial abnormalities were more frequent in patients with CVD than in patients with idiopathic fibrosing interstitial pneumonia. Compared with patients with CVD, those patients with an idiopathic fibrosing interstitial pneumonia showed a higher prevalence of a UIP pattern and lower prevalence of an NSIP pattern as determined by CT. Identification of coexisting extrapulmonary abnormalities on CT can support a diagnosis of CVD.
Cappellozza, José Antonio Zuega; Guedes, Fabio Pinto; Nary, Hugo; Capelozza, Leopoldino; Cardoso, Mauricio de Almeida
2015-01-01
Introduction: Cone-Beam Computed Tomography (CBCT) is essential for tridimensional planning of orthognathic surgery, as it allows visualization and evaluation of bone structures and mineralized tissues. Tomographic slices allow evaluation of tooth inclination and individualization of movement performed during preoperative decompensation. The aim of this paper was to assess maxillary and mandibular incisors inclination pre and post orthodontic decompensation in skeletal Class III malocclusion. Methods: The study was conducted on six individuals with skeletal Class III malocclusion, surgically treated, who had Cone-Beam Computed Tomographic scans obtained before and after orthodontic decompensation. On multiplanar reconstruction view, tomographic slices (axial, coronal and sagittal) were obtained on the long axis of each incisor. The sagittal slice was used for measurement taking, whereas the references used to assess tooth inclination were the long axis of maxillary teeth in relation to the palatal plane and the long axis of mandibular teeth in relation to the mandibular plane. Results: There was significant variation in the inclination of incisors before and after orthodontic decompensation. This change was of greater magnitude in the mandibular arch, evidencing that natural compensation is more effective in this arch, thereby requiring more intensive decompensation. Conclusion: When routinely performed, the protocols of decompensation treatment in surgical individuals often result in intensive movements, which should be reevaluated, since the extent of movement predisposes to reduction in bone attachment levels and root length. PMID:26560818
Chhabra, Lovely; Sareen, Pooja; Gandagule, Amit; Spodick, David H
2012-03-01
Verticalization of the frontal P vector in patients older than 45 years is virtually diagnostic of pulmonary emphysema (sensitivity, 96%; specificity, 87%). We investigated the correlation of P vector and the computed tomographic visual score of emphysema (VSE) in patients with established diagnosis of chronic obstructive pulmonary disease/emphysema. High-resolution computed tomographic scans of 26 patients with emphysema (age, >45 years) were reviewed to assess the type and extent of emphysema using the subjective visual scoring. Electrocardiograms were independently reviewed to determine the frontal P vector. The P vector and VSE were compared for statistical correlation. Both P vector and VSE were also directly compared with the forced expiratory volume at 1 second. The VSE and the orientation of the P vector (ÂP) had an overall significant positive correlation (r = +0.68; P = .0001) in all patients, but the correlation was very strong in patients with predominant lower-lobe emphysema (r = +0.88; P = .0004). Forced expiratory volume at 1 second and ÂP had almost a linear inverse correlation in predominant lower-lobe emphysema (r = -0.92; P < .0001). Orientation of the P vector positively correlates with visually scored emphysema. Both ÂP and VSE are strong reflectors of qualitative lung function in patients with predominant lower-lobe emphysema. A combination of more vertical ÂP and predominant lower-lobe emphysema reflects severe obstructive lung dysfunction. Copyright © 2012 Elsevier Inc. All rights reserved.
Codner, E C; Lurus, A G; Miller, J B; Gavin, P R; Gallina, A; Barbee, D D
1993-04-01
Computed tomography was evaluated as a noninvasive technique for the diagnosis of chronic nasal disease in dogs. Computed tomographic images, radiographs, and histopathologic findings were compared in 11 dogs with chronic nasal disease. Definitive diagnosis was made following traumatic nasal flush, exploratory surgery, or necropsy. The study included 8 dogs with intranasal tumors, 2 dogs with bacterial rhinitis (Pasteurella sp), and 1 dog with mycotic rhinitis (Aspergillus sp). Computed tomography was superior to radiography in defining the extent of the disease process and in differentiating infectious rhinitis from nasal neoplasms. It defined lesions in the palate, nasopharyngeal meatus, maxillary sinus, caudal ethmoturbinates, and periorbital tissues that were difficult to demonstrate by use of conventional radiography. Tumors appeared as space-occupying lesions that obliterated the turbinates, caused deviation of the nasal septum, and eroded bone. Rhinitis appeared as a cavitating lesion that spared the paranasal sinuses, thickened and distorted the turbinates, and widened the meatus. Although morphologically distinct on computed tomographic images, infectious rhinitis and nasal neoplasms could not be differentiated by attenuation measurements or degree of contrast enhancement. Computed tomography appeared to be a reliable, noninvasive technique for the diagnosis of chronic nasal disease in dogs, and a promising alternative to diagnostic techniques currently in use.
Field-portable lensfree tomographic microscope†
Isikman, Serhan O.; Bishara, Waheb; Sikora, Uzair; Yaglidere, Oguzhan; Yeah, John; Ozcan, Aydogan
2011-01-01
We present a field-portable lensfree tomographic microscope, which can achieve sectional imaging of a large volume (~20 mm3) on a chip with an axial resolution of <7 μm. In this compact tomographic imaging platform (weighing only ~110 grams), 24 light-emitting diodes (LEDs) that are each butt-coupled to a fibre-optic waveguide are controlled through a cost-effective micro-processor to sequentially illuminate the sample from different angles to record lensfree holograms of the sample that is placed on the top of a digital sensor array. In order to generate pixel super-resolved (SR) lensfree holograms and hence digitally improve the achievable lateral resolution, multiple sub-pixel shifted holograms are recorded at each illumination angle by electromagnetically actuating the fibre-optic waveguides using compact coils and magnets. These SR projection holograms obtained over an angular range of ~50° are rapidly reconstructed to yield projection images of the sample, which can then be back-projected to compute tomograms of the objects on the sensor-chip. The performance of this compact and light-weight lensfree tomographic microscope is validated by imaging micro-beads of different dimensions as well as a Hymenolepis nana egg, which is an infectious parasitic flatworm. Achieving a decent three-dimensional spatial resolution, this field-portable on-chip optical tomographic microscope might provide a useful toolset for telemedicine and high-throughput imaging applications in resource-poor settings. PMID:21573311
Single photon emission tomography using 99mTc-HM-PAO in the investigation of dementia.
Neary, D; Snowden, J S; Shields, R A; Burjan, A W; Northen, B; MacDermott, N; Prescott, M C; Testa, H J
1987-01-01
Single photon emission tomographic imaging of the brain using 99mTc HM-PAO was carried out in patients with a clinical diagnosis of Alzheimer's disease, non-Alzheimer frontal-lobe dementia, and progressive supranuclear palsy. Independent assessment of reductions in uptake revealed posterior hemisphere abnormalities in the majority of the Alzheimer group, and selective anterior hemisphere abnormalities in both other groups. The findings were consistent with observed patterns of mental impairment. The imaging technique has potential value in the differential diagnosis of primary cerebral atrophy. Images PMID:3499484
Imaging open-path Fourier transform infrared spectrometer for 3D cloud profiling
NASA Astrophysics Data System (ADS)
Rentz Dupuis, Julia; Mansur, David J.; Vaillancourt, Robert; Carlson, David; Evans, Thomas; Schundler, Elizabeth; Todd, Lori; Mottus, Kathleen
2010-04-01
OPTRA has developed an imaging open-path Fourier transform infrared (I-OP-FTIR) spectrometer for 3D profiling of chemical and biological agent simulant plumes released into test ranges and chambers. An array of I-OP-FTIR instruments positioned around the perimeter of the test site, in concert with advanced spectroscopic algorithms, enables real time tomographic reconstruction of the plume. The approach is intended as a referee measurement for test ranges and chambers. This Small Business Technology Transfer (STTR) effort combines the instrumentation and spectroscopic capabilities of OPTRA, Inc. with the computed tomographic expertise of the University of North Carolina, Chapel Hill. In this paper, we summarize the design and build and detail system characterization and test of a prototype I-OP-FTIR instrument. System characterization includes radiometric performance and spectral resolution. Results from a series of tomographic reconstructions of sulfur hexafluoride plumes in a laboratory setting are also presented.
Imaging open-path Fourier transform infrared spectrometer for 3D cloud profiling
NASA Astrophysics Data System (ADS)
Rentz Dupuis, Julia; Mansur, David J.; Engel, James R.; Vaillancourt, Robert; Todd, Lori; Mottus, Kathleen
2008-04-01
OPTRA and University of North Carolina are developing an imaging open-path Fourier transform infrared (I-OP-FTIR) spectrometer for 3D profiling of chemical and biological agent simulant plumes released into test ranges and chambers. An array of I-OP-FTIR instruments positioned around the perimeter of the test site, in concert with advanced spectroscopic algorithms, enables real time tomographic reconstruction of the plume. The approach will be considered as a candidate referee measurement for test ranges and chambers. This Small Business Technology Transfer (STTR) effort combines the instrumentation and spectroscopic capabilities of OPTRA, Inc. with the computed tomographic expertise of the University of North Carolina, Chapel Hill. In this paper, we summarize progress to date and overall system performance projections based on the instrument, spectroscopy, and tomographic reconstruction accuracy. We then present a preliminary optical design of the I-OP-FTIR.
Song, G Y; Lockhart, M E; Smith, J K; Burns, J R; Kenney, P J
2005-01-01
Unenhanced helical computed tomography has played an increasingly important role in the management of urinary tract stones, guiding diagnosis and control of calculus disease. We report computed tomographic and radiographic appearances of a renal calculus composed of pseudoephedrine and guaifenesin in a patient who abused over-the-counter allergy medication.
Concurrent EEG And NIRS Tomographic Imaging Based on Wearable Electro-Optodes
2014-04-13
Interfaces ( BCIs ), and other systems in the same computational framework. Figure 11 below shows...Improving Brain-‐Computer Interfaces Using Independent Component Analysis, In: Towards Future BCIs , 2012
Chen, Lih-Shyang; Hsu, Ta-Wen; Chang, Shu-Han; Lin, Chih-Wen; Chen, Yu-Ruei; Hsieh, Chin-Chiang; Han, Shu-Chen; Chang, Ku-Yaw; Hou, Chun-Ju
2017-01-01
Objective: In traditional surface rendering (SR) computed tomographic endoscopy, only the shape of endoluminal lesion is depicted without gray-level information unless the volume rendering technique is used. However, volume rendering technique is relatively slow and complex in terms of computation time and parameter setting. We use computed tomographic colonography (CTC) images as examples and report a new visualization technique by three-dimensional gray level mapping (GM) to better identify and differentiate endoluminal lesions. Methods: There are 33 various endoluminal cases from 30 patients evaluated in this clinical study. These cases were segmented using gray-level threshold. The marching cube algorithm was used to detect isosurfaces in volumetric data sets. GM is applied using the surface gray level of CTC. Radiologists conducted the clinical evaluation of the SR and GM images. The Wilcoxon signed-rank test was used for data analysis. Results: Clinical evaluation confirms GM is significantly superior to SR in terms of gray-level pattern and spatial shape presentation of endoluminal cases (p < 0.01) and improves the confidence of identification and clinical classification of endoluminal lesions significantly (p < 0.01). The specificity and diagnostic accuracy of GM is significantly better than those of SR in diagnostic performance evaluation (p < 0.01). Conclusion: GM can reduce confusion in three-dimensional CTC and well correlate CTC with sectional images by the location as well as gray-level value. Hence, GM increases identification and differentiation of endoluminal lesions, and facilitates diagnostic process. Advances in knowledge: GM significantly improves the traditional SR method by providing reliable gray-level information for the surface points and is helpful in identification and differentiation of endoluminal lesions according to their shape and density. PMID:27925483
Computed Tomographic Morphometry of the Internal Anatomy of Mandibular Second Primary Molars.
Kurthukoti, Ameet J; Sharma, Pranjal; Swamy, Dinesh Francis; Shashidara, R; Swamy, Elaine Barretto
2015-01-01
Need for the study: The most important procedure for a successful endodontic treatment is the cleaning and shaping of the canal system. Understanding the internal anatomy of teeth provides valuable information to the clinician that would help him achieve higher clinical success during endodontic therapy. To evaluate by computed tomography-the internal anatomy of mandibular second primary molars with respect to the number of canals, cross-sectional shape of canals, cross-sectional area of canals and the root dentin thickness. A total of 31 mandibular second primary molars were subjected to computed-tomographic evaluation in the transverse plane, after mounting them in a prefabricated template. The images, thus, obtained were analyzed using De-winter Bio-wizard® software. All the samples demonstrated two canals in the mesial root, while majority of the samples (65.48%) demonstrated two canals in the distal root. The cross-sectional images of the mesial canals demonstrated a round shape, while the distal canals demonstrated an irregular shape. The root dentin thickness was highly reduced on the distal aspect of mesial and mesial aspect of distal canals. The mandibular second primary molars demonstrated wide variation and complexities in their internal anatomy. A thorough understanding of the complexity of the root canal system is essential for understanding the principles and problems of shaping and cleaning, determining the apical limits and dimensions of canal preparations, and for performing successful endodontic procedures. How to cite this article: Kurthukoti AJ, Sharma P, Swamy DF, Shashidara R, Swamy EB. Computed Tomographic Morphometry of the Internal Anatomy of Mandibular Second Primary Molars. Int J Clin Pediatr Dent 2015;8(3):202-207.
Anolik, Rachel A; Allori, Alexander C; Pourtaheri, Navid; Rogers, Gary F; Marcus, Jeffrey R
2016-05-01
The purpose of this study was to evaluate the utility of a previously validated interfrontal angle for classification of severity of metopic synostosis and as an aid to operative decision-making. An expert panel was asked to study 30 cases ranging from minor to severe metopic synostosis. Based on computed tomographic images of the skull and clinical photographs, they classified the severity of trigonocephaly (1 = normal, 2 = mild, 3 = moderate, and 4 = severe) and management (0 = nonoperative and 1 = operative). The severity scores and management reported by experts were then pooled and matched with the interfrontal angle computed from each respective computed tomographic scan. A threshold was identified at which most experts agree on operative management. Expert severity scores were higher for more acute interfrontal angles. There was a high concordance at the extremes of classifications, severe (4) and normal (1) (p < 0.0001); however, between interfrontal angles of 114.3 and 136.1 degrees, there exists a "gray zone," with severe discordance in expert rankings. An operative threshold of 118.2 degrees was identified, with the interfrontal angle able to predict the expert panel's decision to proceed with surgery 87.6 percent of the time. The interfrontal angle has been previously validated as a simple, accurate, and reproducible means for diagnosing trigonocephaly, but must be obtained from computed tomographic data. In this article, the authors demonstrate that the interfrontal angle can be used to further characterize the severity of trigonocephaly. It also correlated with expert decision-making for operative versus nonoperative management. This tool may be used as an adjunct to clinical decision-making when the decision to proceed with surgery may not be straightforward. Diagnostic, V.
Computed Tomographic Morphometry of the Internal Anatomy of Mandibular Second Primary Molars
Sharma, Pranjal; Swamy, Dinesh Francis; Shashidara, R; Swamy, Elaine Barretto
2015-01-01
ABSTRACT Need for the study: The most important procedure for a successful endodontic treatment is the cleaning and shaping of the canal system. Understanding the internal anatomy of teeth provides valuable information to the clinician that would help him achieve higher clinical success during endodontic therapy. Aims: To evaluate by computed tomography—the internal anatomy of mandibular second primary molars with respect to the number of canals, cross-sectional shape of canals, cross-sectional area of canals and the root dentin thickness. Materials and methods: A total of 31 mandibular second primary molars were subjected to computed-tomographic evaluation in the transverse plane, after mounting them in a prefabricated template. The images, thus, obtained were analyzed using De-winter Bio-wizard® software. Results: All the samples demonstrated two canals in the mesial root, while majority of the samples (65.48%) demonstrated two canals in the distal root. The cross-sectional images of the mesial canals demonstrated a round shape, while the distal canals demonstrated an irregular shape. The root dentin thickness was highly reduced on the distal aspect of mesial and mesial aspect of distal canals. Conclusion: The mandibular second primary molars demonstrated wide variation and complexities in their internal anatomy. A thorough understanding of the complexity of the root canal system is essential for understanding the principles and problems of shaping and cleaning, determining the apical limits and dimensions of canal preparations, and for performing successful endodontic procedures. How to cite this article: Kurthukoti AJ, Sharma P, Swamy DF, Shashidara R, Swamy EB. Computed Tomographic Morphometry of the Internal Anatomy of Mandibular Second Primary Molars. Int J Clin Pediatr Dent 2015;8(3):202-207. PMID:26628855
Brain Correlates of Stuttering and Syllable Production: Gender Comparison and Replication.
ERIC Educational Resources Information Center
Ingham, Roger J.; Fox, Peter T.; Ingham, Janis C.; Xiong, Jinhu; Zamarripa, Frank; Hardies, L. Jean; Lancaster, Jack L.
2004-01-01
This article reports a gender replication study of the P. T. Fox et a. (2000) performance correlation analysis of neural systems that distinguish between normal and stuttered speech in adult males. Positron-emission tomographic (PET) images of cerebral blood flow (CBF) were correlated with speech behavior scores obtained during PET imaging for 10…
Tomographic assessment of the spine in children with spondylocostal dysotosis syndrome
Kaissi, Ali Al; Klaushofer, Klaus; Grill, Franz
2010-01-01
OBJECTIVE: The aim of this study was to perform a detailed tomographic analysis of the skull base, craniocervical junction, and the entire spine in seven patients with spondylocostal dysostosis syndrome. METHOD: Detailed scanning images have been organized in accordance with the most prominent clinical pathology. The reasons behind plagiocephaly, torticollis, short immobile neck, scoliosis and rigid back have been detected. Radiographic documentation was insufficient modality. RESULTS: Detailed computed tomography scans provided excellent delineation of the osseous abnormality pattern in our patients. CONCLUSION: This article throws light on the most serious osseous manifestations of spondylocostal dysostosis syndrome. PMID:21120293
Types of traumatic brain injury and regional cerebral blood flow assessed by 99mTc-HMPAO SPECT.
Yamakami, I; Yamaura, A; Isobe, K
1993-01-01
To investigate the relationship between focal and diffuse traumatic brain injury (TBI) and regional cerebral blood flow (rCBF), rCBF changes in the first 24 hours post-trauma were studied in 12 severe head trauma patients using single photon emission computed tomography (SPECT) with 99mtechnetium-hexamethyl propyleneamine oxime. Patients were classified as focal or diffuse TBI based on x-ray computed tomographic (X-CT) findings and neurological signs. In six patients with focal damage, SPECT demonstrated 1) perfusion defect (focal severe ischemia) in the brain region larger than the brain contusion by X-CT, 2) hypoperfusion (focal CBF reduction) in the brain region without abnormality by X-CT, and 3) localized hyperperfusion (focal CBF increase) in the surgically decompressed brain after decompressive craniectomy. Focal damage may be associated with a heterogeneous CBF change by causing various focal CBF derangements. In six patients with diffuse damage, SPECT revealed hypoperfusion in only one patient. Diffuse damage may be associated with a homogeneous CBF change by rarely causing focal CBF derangements. The type of TBI, focal or diffuse, determines the type of CBF change, heterogeneous or homogeneous, in the acute severe head trauma patient.
Jini service to reconstruct tomographic data
NASA Astrophysics Data System (ADS)
Knoll, Peter; Mirzaei, S.; Koriska, K.; Koehn, H.
2002-06-01
A number of imaging systems rely on the reconstruction of a 3- dimensional model from its projections through the process of computed tomography (CT). In medical imaging, for example magnetic resonance imaging (MRI), positron emission tomography (PET), and Single Computer Tomography (SPECT) acquire two-dimensional projections of a three dimensional projections of a three dimensional object. In order to calculate the 3-dimensional representation of the object, i.e. its voxel distribution, several reconstruction algorithms have been developed. Currently, mainly two reconstruct use: the filtered back projection(FBP) and iterative methods. Although the quality of iterative reconstructed SPECT slices is better than that of FBP slices, such iterative algorithms are rarely used for clinical routine studies because of their low availability and increased reconstruction time. We used Jini and a self-developed iterative reconstructions algorithm to design and implement a Jini reconstruction service. With this service, the physician selects the patient study from a database and a Jini client automatically discovers the registered Jini reconstruction services in the department's Intranet. After downloading the proxy object the this Jini service, the SPECT acquisition data are reconstructed. The resulting transaxial slices are visualized using a Jini slice viewer, which can be used for various imaging modalities.
NASA Astrophysics Data System (ADS)
La Riviere, P. J.; Pan, X.; Penney, B. C.
1998-06-01
Scintimammography, a nuclear-medicine imaging technique that relies on the preferential uptake of Tc-99m-sestamibi and other radionuclides in breast malignancies, has the potential to provide differentiation of mammographically suspicious lesions, as well as outright detection of malignancies in women with radiographically dense breasts. In this work we use the ideal-observer framework to quantify the detectability of a 1-cm lesion using three different imaging geometries: the planar technique that is the current clinical standard, conventional single-photon emission computed tomography (SPECT), in which the scintillation cameras rotate around the entire torso, and dedicated breast SPECT, in which the cameras rotate around the breast alone. We also introduce an adaptive smoothing technique for the processing of planar images and of sinograms that exploits Fourier transforms to achieve effective multidimensional smoothing at a reasonable computational cost. For the detection of a 1-cm lesion with a clinically typical 6:1 tumor-background ratio, we find ideal-observer signal-to-noise ratios (SNR) that suggest that the dedicated breast SPECT geometry is the most effective of the three, and that the adaptive, two-dimensional smoothing technique should enhance lesion detectability in the tomographic reconstructions.
MIMO nonlinear ultrasonic tomography by propagation and backpropagation method.
Dong, Chengdong; Jin, Yuanwei
2013-03-01
This paper develops a fast ultrasonic tomographic imaging method in a multiple-input multiple-output (MIMO) configuration using the propagation and backpropagation (PBP) method. By this method, ultrasonic excitation signals from multiple sources are transmitted simultaneously to probe the objects immersed in the medium. The scattering signals are recorded by multiple receivers. Utilizing the nonlinear ultrasonic wave propagation equation and the received time domain scattered signals, the objects are to be reconstructed iteratively in three steps. First, the propagation step calculates the predicted acoustic potential data at the receivers using an initial guess. Second, the difference signal between the predicted value and the measured data is calculated. Third, the backpropagation step computes updated acoustical potential data by backpropagating the difference signal to the same medium computationally. Unlike the conventional PBP method for tomographic imaging where each source takes turns to excite the acoustical field until all the sources are used, the developed MIMO-PBP method achieves faster image reconstruction by utilizing multiple source simultaneous excitation. Furthermore, we develop an orthogonal waveform signaling method using a waveform delay scheme to reduce the impact of speckle patterns in the reconstructed images. By numerical experiments we demonstrate that the proposed MIMO-PBP tomographic imaging method results in faster convergence and achieves superior imaging quality.
Computer-aided interpretation approach for optical tomographic images
NASA Astrophysics Data System (ADS)
Klose, Christian D.; Klose, Alexander D.; Netz, Uwe J.; Scheel, Alexander K.; Beuthan, Jürgen; Hielscher, Andreas H.
2010-11-01
A computer-aided interpretation approach is proposed to detect rheumatic arthritis (RA) in human finger joints using optical tomographic images. The image interpretation method employs a classification algorithm that makes use of a so-called self-organizing mapping scheme to classify fingers as either affected or unaffected by RA. Unlike in previous studies, this allows for combining multiple image features, such as minimum and maximum values of the absorption coefficient for identifying affected and not affected joints. Classification performances obtained by the proposed method were evaluated in terms of sensitivity, specificity, Youden index, and mutual information. Different methods (i.e., clinical diagnostics, ultrasound imaging, magnet resonance imaging, and inspection of optical tomographic images), were used to produce ground truth benchmarks to determine the performance of image interpretations. Using data from 100 finger joints, findings suggest that some parameter combinations lead to higher sensitivities, while others to higher specificities when compared to single parameter classifications employed in previous studies. Maximum performances are reached when combining the minimum/maximum ratio of the absorption coefficient and image variance. In this case, sensitivities and specificities over 0.9 can be achieved. These values are much higher than values obtained when only single parameter classifications were used, where sensitivities and specificities remained well below 0.8.
NASA Astrophysics Data System (ADS)
Staton, Robert J.
Of the various types of imaging modalities used in pediatric radiology, fluoroscopy and computed tomography (CT) have the highest associated radiation dose. While these examinations are commonly used for pediatric patients, little data exists on the magnitude of the organ and effective dose values for these procedures. Calculation of these dose values is necessary because of children's increased sensitivity to radiation and their long life expectancy for which to express radiation's latent effects. In this study, a newborn tomographic phantom has been implemented in a radiation transport code to evaluate organ and effective doses for newborn patients in commonly performed fluoroscopy and CT examinations. Organ doses were evaluated for voiding cystourethrogram (VCUG) fluoroscopy studies of infant patients. Time-sequence analysis was performed for videotaped VCUG studies of five different patients. Organ dose values were then estimated for each patient through Monte Carlo (MC) simulations. The effective dose values of the VCUG examination for five patients ranged from 0.6 mSv to 3.2 mSv, with a mean of 1.8 +/- 0.9 mSv. Organ doses were also assessed for infant upper gastrointestinal (UGI) fluoroscopy exams. The effective dose values of the UGI examinations for five patients ranged from 1.05 mSv to 5.92 mSv, with a mean of 2.90 +/- 1.97 mSv. MC simulations of helical multislice CT (MSCT) exams were also completed using, the newborn tomographic phantom and a stylized newborn phantom. The helical path of the source, beam shaping filter, beam profile, patient table, were all included in the MC simulations of the helical MSCT scanner. Organ doses and effective doses and their dependence on scan parameters were evaluated for newborn patients. For all CT scans, the effective dose was found to range approximately 1-13 mSv, with the largest values occurring for CAP scans. Tube current modulation strategies to reduce patient dose were also evaluated for newborn patients. Overall, utilization of the newborn tomographic phantom in MC simulations has shown the need for and usefulness of pediatric tomographic phantoms. The newborn tomographic model has shown more versatility and realistic anatomical modeling when compared to the existing stylized newborn phantom. This work has provided important organ dose data for infant patients in common examinations in pediatric radiology.
Multiphoton tomography of intratissue tattoo nanoparticles
NASA Astrophysics Data System (ADS)
König, Karsten
2012-02-01
Most of today's intratissue tattoo pigments are unknown nanoparticles. So far, there was no real control of their use due to the absence of regulations. Some of the tattoo pigments contain carcinogenic amines e.g. azo pigment Red 22. Nowadays, the European Union starts to control the administration of tattoo pigments. There is an interest to obtain information on the intratissue distribution, their interaction with living cells and the extracellular matrix, and the mechanisms behind laser tattoo removal. Multiphoton tomographs are novel biosafety and imaging tools that can provide such information non-invasively and without further labeling. When using the spectral FLIM module, spatially-resolved emission spectra, excitation spectra, and fluorescence lifetimes can pr provided. Multiphoton tomographs are used by all major cosmetic comapanies to test the biosafety of sunscreen nanoparticles.
Three-dimensional Image Reconstruction in J-PET Using Filtered Back-projection Method
NASA Astrophysics Data System (ADS)
Shopa, R. Y.; Klimaszewski, K.; Kowalski, P.; Krzemień, W.; Raczyński, L.; Wiślicki, W.; Białas, P.; Curceanu, C.; Czerwiński, E.; Dulski, K.; Gajos, A.; Głowacz, B.; Gorgol, M.; Hiesmayr, B.; Jasińska, B.; Kisielewska-Kamińska, D.; Korcyl, G.; Kozik, T.; Krawczyk, N.; Kubicz, E.; Mohammed, M.; Pawlik-Niedźwiecka, M.; Niedźwiecki, S.; Pałka, M.; Rudy, Z.; Sharma, N. G.; Sharma, S.; Silarski, M.; Skurzok, M.; Wieczorek, A.; Zgardzińska, B.; Zieliński, M.; Moskal, P.
We present a method and preliminary results of the image reconstruction in the Jagiellonian PET tomograph. Using GATE (Geant4 Application for Tomographic Emission), interactions of the 511 keV photons with a cylindrical detector were generated. Pairs of such photons, flying back-to-back, originate from e+e- annihilations inside a 1-mm spherical source. Spatial and temporal coordinates of hits were smeared using experimental resolutions of the detector. We incorporated the algorithm of the 3D Filtered Back Projection, implemented in the STIR and TomoPy software packages, which differ in approximation methods. Consistent results for the Point Spread Functions of ~5/7,mm and ~9/20, mm were obtained, using STIR, for transverse and longitudinal directions, respectively, with no time of flight information included.
Creating three-dimensional tooth models from tomographic images.
Lima da Silva, Isaac Newton; Barbosa, Gustavo Frainer; Soares, Rodrigo Borowski Grecco; Beltrao, Maria Cecilia Gomes; Spohr, Ana Maria; Mota, Eduardo Golcalves; Oshima, Hugo Mitsuo Silva; Burnett, Luiz Henrique
2008-01-01
The use of Finite Element Analysis (FEA) is becoming very frequent in Dentistry. However, most of the three-dimensional models presented by the literature for teeth are limited in terms of geometry. Discrepancy in shape and dimensions can cause wrong results to occur. Sharp cusps and faceted contour can produce stress concentrations, which are incoherent with the reality. The aim of this study was the processing of tomographic images in order to develop an advanced three-dimensional reconstruction of the anatomy of a molar tooth and the integration of the resulting solid with commercially available CAD/CAE software. Computed tomographic images were obtained from 0.5 mm thick slices of mandibular molar and transferred to commercial cad software. Once the point cloud data have been generated, the work on these points started to get to the solid model of the tooth with Pro/Engineer software. The obtained tooth model showed very accurate shape and dimensions, as it was obtained from real tooth data with error of 0.0 to -0.8 mm. The methodology presented was efficient for creating a biomodel of a tooth from tomographic images that realistically represented its anatomy.
Dugernier, Jonathan; Hesse, Michel; Jumetz, Thibaud; Bialais, Emilie; Roeseler, Jean; Depoortere, Virginie; Michotte, Jean-Bernard; Wittebole, Xavier; Ehrmann, Stephan; Laterre, Pierre-François; Jamar, François; Reychler, Gregory
2017-10-01
High-flow nasal cannula use is developing in ICUs. The aim of this study was to compare aerosol efficiency by using two nebulizers through a high-flow nasal cannula: the most commonly used jet nebulizer (JN) and a more efficient vibrating-mesh nebulizer (VN). Aerosol delivery of diethylenetriaminepentaacetic acid labeled with technetium-99m (4 mCi/4 mL) to the lungs by using a VN (Aerogen Solo ® ; Aerogen Ltd., Galway, Ireland) and a constant-output JN (Opti-Mist Plus Nebulizer ® ; ConvaTec, Bridgewater, NJ) through a high-flow nasal cannula (Optiflow ® ; Fisher & Paykel, New Zealand) was compared in six healthy subjects. Flow rate was set at 30 L/min through the heated humidified circuit. Pulmonary and extrapulmonary deposition was measured by single-photon emission computed tomography combined with a low-dose computed tomographic scan and by planar scintigraphy. Lung deposition was only 3.6 (2.1-4.4) and 1 (0.7-2)% of the nominal dose with the VN and the JN, respectively (p < 0.05). The JN showed higher retained doses than the VN. However, both nebulizers were associated with substantial deposition in the single limb circuit, the humidification chamber, and the nasal cannula [58.2 (51.6-61.6)% of the nominal dose with the VN versus 19.2 (15.8-22.9)% of the nominal dose with the JN, p < 0.05] and in the upper respiratory tract [17.6 (13.4-27.9)% of the nominal dose with the VN and 8.6 (6.0-11.0)% of the nominal dose with the JN, p < 0.05], especially in the nasal cavity. In the specific conditions of the study, pulmonary drug delivery through the high-flow nasal cannula is about 1%-4% of the initial amount of drugs placed in the nebulizer, despite the higher efficiency of the VN as compared with the JN.
Computerized tomography using video recorded fluoroscopic images
NASA Technical Reports Server (NTRS)
Kak, A. C.; Jakowatz, C. V., Jr.; Baily, N. A.; Keller, R. A.
1975-01-01
A computerized tomographic imaging system is examined which employs video-recorded fluoroscopic images as input data. By hooking the video recorder to a digital computer through a suitable interface, such a system permits very rapid construction of tomograms.
Diffractive Optical Elements for Spectral Imaging
NASA Technical Reports Server (NTRS)
Wilson, D.; Maker, P.; Muller, R.; Mourolis, P.; Descour, M.; Volin, C.; Dereniak, E.
2000-01-01
Diffractive optical elements fabricated on flat and non-flat substrates frequently act as dispersive elements in imaging spectrometers. We describe the design and electron-beam fabrication of blazed and computer-generated-hologram gratings for slit and tomographic imaging spectrometer.
Diffractive Optical Elements for Spectral Imaging
NASA Technical Reports Server (NTRS)
Wilson, D.; Maker, P.; Muller, R.; Maker, P.; Mouroulis, P.; Descour, M.; Volin, C.; Dereniak, E.
2000-01-01
Diffractive optical elements fabricated on flat and non-flat substrates frequently act as dispersive elements in imaging spectrometers. We describe the design and electron-beam fabrication of blazed and computer-generated-hologram gratings for slit and tomographic imaging spectrometers.
Conservative orthodontic treatment of mandibular bilateral condyle fracture.
Gašpar, Goran; Brakus, Ivan; Kovačić, Ivan
2014-09-01
Maxillofacial trauma is rare in children younger than the age of 5 years (range 0.6%-1.2%), and they can require different clinical treatment strategies compared with fractures in the adult population because of concerns regarding mandibular growth and development of dentition. A 5-year-old girl with a history of falling from a bicycle 7 hours earlier was referred to the department of oral and maxillofacial surgery. Multislice computed tomographic examination demonstrated a bilateral fracture of the mandibular condyle neck associated with minimal fracture of the alveolar ridge of the maxilla. The multislice computed tomographic scan also demonstrated dislocation on the right condyle neck and, on the left side, a medial inclination of approximately 45 degrees associated with greenstick fracture of the right parasymphysis region. In this particular case, orthodontic rubber elastics in combination with fixed orthodontic brackets provided good results in the treatment of bilateral condyle neck fractures associated with greenstick fracture of parasymphysis.
A tomographic technique for aerodynamics at transonic speeds
NASA Technical Reports Server (NTRS)
Lee, G.
1985-01-01
Computer aided tomography (CAT) provides a means of noninvasively measuring the air density distribution around an aerodynamic model. This technique is global in that a large portion of the flow field can be measured. A test of the applicability of CAT to transonic velocities was studied. A hemispherical-nose cylinder afterbody model was tested at a Mach number of 0.8 with a new laser holographic interferometer at the 2- by 2-Foot Transonic Wind Tunnel. Holograms of the flow field were taken and were reconstructed into interferograms. The fringe distribution (a measure of the local densities) was digitized for subsequent data reduction. A computer program based on the Fourier-transform technique was developed to convert the fringe distribution into three-dimensional densities around the model. Theoretical aerodynamic densities were calculated for evaluating and assessing the accuracy of the data obtained from the tomographic method.
Gadolinium-enhanced computed tomographic angiography: current status.
Rosioreanu, Alex; Alberico, Ronald A; Litwin, Alan; Hon, Man; Grossman, Zachary D; Katz, Douglas S
2005-01-01
This article reviews the research to date, as well as our clinical experience from two institutions, on gadolinium-enhanced computed tomographic angiography (gCTA) for imaging the body. gCTA may be an appropriate examination for the small percentage of patients who would benefit from noninvasive vascular imaging, but who have contraindications to both iodinated contrast and magnetic resonance imaging. gCTA is more expensive than CTA with iodinated contrast, due to the dose of gadolinium administered, and gCTA has limitations compared with CTA with iodinated contrast, in that parenchymal organs are not optimally enhanced at doses of 0.5 mmol/kg or lower. However, in our experience, gCTA has been a very useful problem-solving examination in carefully selected patients. With the advent of 16-64 detector CT, in combination with bolus tracking, we believe that the overall dose of gadolinium needed for diagnostic CTA examinations, while relatively high, can be safely administered.
Thompson, Randall C; Allam, Adel H; Zink, Albert; Wann, L Samuel; Lombardi, Guido P; Cox, Samantha L; Frohlich, Bruno; Sutherland, M Linda; Sutherland, James D; Frohlich, Thomas C; King, Samantha I; Miyamoto, Michael I; Monge, Janet M; Valladolid, Clide M; El-Halim Nur El-Din, Abd; Narula, Jagat; Thompson, Adam M; Finch, Caleb E; Thomas, Gregory S
2014-06-01
Although atherosclerosis is widely thought to be a disease of modernity, computed tomographic evidence of atherosclerosis has been found in the bodies of a large number of mummies. This article reviews the findings of atherosclerotic calcifications in the remains of ancient people-humans who lived across a very wide span of human history and over most of the inhabited globe. These people had a wide range of diets and lifestyles and traditional modern risk factors do not thoroughly explain the presence and easy detectability of this disease. Nontraditional risk factors such as the inhalation of cooking fire smoke and chronic infection or inflammation might have been important atherogenic factors in ancient times. Study of the genetic and environmental risk factors for atherosclerosis in ancient people may offer insights into this common modern disease. Copyright © 2014 World Heart Federation (Geneva). Published by Elsevier B.V. All rights reserved.
Optical tomographic detection of rheumatoid arthritis with computer-aided classification schemes
NASA Astrophysics Data System (ADS)
Klose, Christian D.; Klose, Alexander D.; Netz, Uwe; Beuthan, Jürgen; Hielscher, Andreas H.
2009-02-01
A recent research study has shown that combining multiple parameters, drawn from optical tomographic images, leads to better classification results to identifying human finger joints that are affected or not affected by rheumatic arthritis RA. Building up on the research findings of the previous study, this article presents an advanced computer-aided classification approach for interpreting optical image data to detect RA in finger joints. Additional data are used including, for example, maximum and minimum values of the absorption coefficient as well as their ratios and image variances. Classification performances obtained by the proposed method were evaluated in terms of sensitivity, specificity, Youden index and area under the curve AUC. Results were compared to different benchmarks ("gold standard"): magnet resonance, ultrasound and clinical evaluation. Maximum accuracies (AUC=0.88) were reached when combining minimum/maximum-ratios and image variances and using ultrasound as gold standard.
Alves, Heitor C; Treurniet, Kilian M; Dutra, Bruna G; Jansen, Ivo G H; Boers, Anna M M; Santos, Emilie M M; Berkhemer, Olvert A; Dippel, Diederik W J; van der Lugt, Aad; van Zwam, Wim H; van Oostenbrugge, Robert J; Lingsma, Hester F; Roos, Yvo B W E M; Yoo, Albert J; Marquering, Henk A; Majoie, Charles B L M
2018-02-01
Thrombus characteristics and collateral score are associated with functional outcome in patients with acute ischemic stroke. It has been suggested that they affect each other. The aim of this study is to evaluate the association between clot burden score, thrombus perviousness, and collateral score and to determine whether collateral score influences the association of thrombus characteristics with functional outcome. Patients with baseline thin-slice noncontrast computed tomography and computed tomographic angiography images from the MR CLEAN trial (Multicenter Randomized Clinical Trial of Endovascular Treatment of Acute Ischemic Stroke in the Netherlands) were included (n=195). Collateral score and clot burden scores were determined on baseline computed tomographic angiography. Thrombus attenuation increase was determined by comparing thrombus density on noncontrast computed tomography and computed tomographic angiography using a semiautomated method. The association of collateral score with clot burden score and thrombus attenuation increase was evaluated with linear regression. Mediation and effect modification analyses were used to assess the influence of collateral score on the association of clot burden score and thrombus attenuation increase with functional outcome. A higher clot burden score (B=0.063; 95% confidence interval, 0.008-0.118) and a higher thrombus attenuation increase (B=0.014; 95% confidence interval, 0.003-0.026) were associated with higher collateral score. Collateral score mediated the association of clot burden score with functional outcome. The association between thrombus attenuation increase and functional outcome was modified by the collateral score, and this association was stronger in patients with moderate and good collaterals. Patients with lower thrombus burden and higher thrombus perviousness scores had higher collateral score. The positive effect of thrombus perviousness on clinical outcome was only present in patients with moderate and high collateral scores. URL: http://www.trialregister.nl. Unique identifier: NTR1804 and URL: http://www.controlled-trials.com Unique identifier: ISRCTN10888758. © 2018 The Authors.
Angelis, G I; Reader, A J; Markiewicz, P J; Kotasidis, F A; Lionheart, W R; Matthews, J C
2013-08-07
Recent studies have demonstrated the benefits of a resolution model within iterative reconstruction algorithms in an attempt to account for effects that degrade the spatial resolution of the reconstructed images. However, these algorithms suffer from slower convergence rates, compared to algorithms where no resolution model is used, due to the additional need to solve an image deconvolution problem. In this paper, a recently proposed algorithm, which decouples the tomographic and image deconvolution problems within an image-based expectation maximization (EM) framework, was evaluated. This separation is convenient, because more computational effort can be placed on the image deconvolution problem and therefore accelerate convergence. Since the computational cost of solving the image deconvolution problem is relatively small, multiple image-based EM iterations do not significantly increase the overall reconstruction time. The proposed algorithm was evaluated using 2D simulations, as well as measured 3D data acquired on the high-resolution research tomograph. Results showed that bias reduction can be accelerated by interleaving multiple iterations of the image-based EM algorithm solving the resolution model problem, with a single EM iteration solving the tomographic problem. Significant improvements were observed particularly for voxels that were located on the boundaries between regions of high contrast within the object being imaged and for small regions of interest, where resolution recovery is usually more challenging. Minor differences were observed using the proposed nested algorithm, compared to the single iteration normally performed, when an optimal number of iterations are performed for each algorithm. However, using the proposed nested approach convergence is significantly accelerated enabling reconstruction using far fewer tomographic iterations (up to 70% fewer iterations for small regions). Nevertheless, the optimal number of nested image-based EM iterations is hard to be defined and it should be selected according to the given application.
NASA Astrophysics Data System (ADS)
Lanusse, F.; Rassat, A.; Starck, J.-L.
2015-06-01
Context. Upcoming spectroscopic galaxy surveys are extremely promising to help in addressing the major challenges of cosmology, in particular in understanding the nature of the dark universe. The strength of these surveys, naturally described in spherical geometry, comes from their unprecedented depth and width, but an optimal extraction of their three-dimensional information is of utmost importance to best constrain the properties of the dark universe. Aims: Although there is theoretical motivation and novel tools to explore these surveys using the 3D spherical Fourier-Bessel (SFB) power spectrum of galaxy number counts Cℓ(k,k'), most survey optimisations and forecasts are based on the tomographic spherical harmonics power spectrum C(ij)_ℓ. The goal of this paper is to perform a new investigation of the information that can be extracted from these two analyses in the context of planned stage IV wide-field galaxy surveys. Methods: We compared tomographic and 3D SFB techniques by comparing the forecast cosmological parameter constraints obtained from a Fisher analysis. The comparison was made possible by careful and coherent treatment of non-linear scales in the two analyses, which makes this study the first to compare 3D SFB and tomographic constraints on an equal footing. Nuisance parameters related to a scale- and redshift-dependent galaxy bias were also included in the computation of the 3D SFB and tomographic power spectra for the first time. Results: Tomographic and 3D SFB methods can recover similar constraints in the absence of systematics. This requires choosing an optimal number of redshift bins for the tomographic analysis, which we computed to be N = 26 for zmed ≃ 0.4, N = 30 for zmed ≃ 1.0, and N = 42 for zmed ≃ 1.7. When marginalising over nuisance parameters related to the galaxy bias, the forecast 3D SFB constraints are less affected by this source of systematics than the tomographic constraints. In addition, the rate of increase of the figure of merit as a function of median redshift is higher for the 3D SFB method than for the 2D tomographic method. Conclusions: Constraints from the 3D SFB analysis are less sensitive to unavoidable systematics stemming from a redshift- and scale-dependent galaxy bias. Even for surveys that are optimised with tomography in mind, a 3D SFB analysis is more powerful. In addition, for survey optimisation, the figure of merit for the 3D SFB method increases more rapidly with redshift, especially at higher redshifts, suggesting that the 3D SFB method should be preferred for designing and analysing future wide-field spectroscopic surveys. CosmicPy, the Python package developed for this paper, is freely available at https://cosmicpy.github.io. Appendices are available in electronic form at http://www.aanda.org
Berlanda, Michele; Zotti, Alessandro; Brandazza, Giada; Poser, Helen; Calò, Pietro; Bernardini, Marco
2011-01-01
Magnetic resonance and computed tomography features of 4 cases of canine congenital vertebral anomalies (CVAs) are discussed. Two of the cases represent unusual presentations for such anomalies that commonly affect screw-tail or toy breeds. Moreover, the combination of CVAs and a congenital peritoneo-pericardial diaphragmatic hernia has never before been imaged. PMID:22654139
[Prostatic abscess. Contribution of the x-ray computed tomography. Apropos of a case].
Husain, A; Touzard, D
1988-01-01
We reported a case of prostatic abscess due to staphylococeus aureus developed in a chronic alcoholic patient. The clinical symptoms and signs were largely masked by prior antibiotic therapy. Computed axial tomographic scanning of the pelvis made the diagnosis and demonstrated the resolution of the prostatic abscess following antibiotic therapy and spontaneous rupture to the urethra.
Fang, Jing-Jing; Liu, Jia-Kuang; Wu, Tzu-Chieh; Lee, Jing-Wei; Kuo, Tai-Hong
2013-05-01
Computer-aided design has gained increasing popularity in clinical practice, and the advent of rapid prototyping technology has further enhanced the quality and predictability of surgical outcomes. It provides target guides for complex bony reconstruction during surgery. Therefore, surgeons can efficiently and precisely target fracture restorations. Based on three-dimensional models generated from a computed tomographic scan, precise preoperative planning simulation on a computer is possible. Combining the interdisciplinary knowledge of surgeons and engineers, this study proposes a novel surgical guidance method that incorporates a built-in occlusal wafer that serves as the positioning reference.Two patients with complex facial deformity suffering from severe facial asymmetry problems were recruited. In vitro facial reconstruction was first rehearsed on physical models, where a customized surgical guide incorporating a built-in occlusal stent as the positioning reference was designed to implement the surgery plan. This study is intended to present the authors' preliminary experience in a complex facial reconstruction procedure. It suggests that in regions with less information, where intraoperative computed tomographic scans or navigation systems are not available, our approach could be an effective, expedient, straightforward aid to enhance surgical outcome in a complex facial repair.
New Severity Indices for Quantifying Single-suture Metopic Craniosynostosis
Ruiz-Correa, Salvador; Starr, Jacqueline R.; Lin, H. Jill; Kapp-Simon, Kathleen A.; Sze, Raymond W.; Ellenbogen, Richard G.; Speltz, Matthew L.; Cunningham, Michael L.
2012-01-01
OBJECTIVE To describe novel severity indices with which to quantify severity of trigonocephaly malformation in children diagnosed with isolated metopic synostosis. METHODS Computed tomographic scans of the cranium were obtained from 38 infants diagnosed with isolated metopic synostosis and 53 age-matched control patients. Volumetric reformations of the cranium were used to trace two-dimensional planes defined by the cranium-base plane and well-defined brain landmarks. For each patient, novel trigonocephaly severity indices (TSI) were computed from outline cranium shapes on each of these planes. The metopic severity index based on measurements of interlandmark distances was also computed and a receiver operating characteristic analysis used to compare the accuracy of classification based on TSIs versus that based on the metopic severity index. RESULTS The proposed TSIs are a sensitive measure of trigonocephaly malformation that can provide a classification accuracy of 96% with a specificity of 95%, in contrast with 82% of the metopic severity index at the same specificity level. CONCLUSIONS We completed exploratory analysis of outline-based severity measurements computed from computed tomographic image planes of the cranium. These TSIs enable quantitative analysis of cranium features in isolated metopic synostosis that may not be accurately detected by analytic tools derived from a sparse set of traditional interlandmark and semilandmark distances. PMID:18797362
A flexible, small positron emission tomography prototype for resource-limited laboratories
NASA Astrophysics Data System (ADS)
Miranda-Menchaca, A.; Martínez-Dávalos, A.; Murrieta-Rodríguez, T.; Alva-Sánchez, H.; Rodríguez-Villafuerte, M.
2015-05-01
Modern small-animal PET scanners typically consist of a large number of detectors along with complex electronics to provide tomographic images for research in the preclinical sciences that use animal models. These systems can be expensive, especially for resource-limited educational and academic institutions in developing countries. In this work we show that a small-animal PET scanner can be built with a relatively reduced budget while, at the same time, achieving relatively high performance. The prototype consists of four detector modules each composed of LYSO pixelated crystal arrays (individual crystal elements of dimensions 1 × 1 × 10 mm3) coupled to position-sensitive photomultiplier tubes. Tomographic images are obtained by rotating the subject to complete enough projections for image reconstruction. Image quality was evaluated for different reconstruction algorithms including filtered back-projection and iterative reconstruction with maximum likelihood-expectation maximization and maximum a posteriori methods. The system matrix was computed both with geometric considerations and by Monte Carlo simulations. Prior to image reconstruction, Fourier data rebinning was used to increase the number of lines of response used. The system was evaluated for energy resolution at 511 keV (best 18.2%), system sensitivity (0.24%), spatial resolution (best 0.87 mm), scatter fraction (4.8%) and noise equivalent count-rate. The system can be scaled-up to include up to 8 detector modules, increasing detection efficiency, and its price may be reduced as newer solid state detectors become available replacing the traditional photomultiplier tubes. Prototypes like this may prove to be very valuable for educational, training, preclinical and other biological research purposes.
Iskandrian, A S; Powers, J; Cave, V; Wasserleben, V; Cassell, D; Heo, J
1995-01-01
This study examined the ability of dynamic 123I-labeled iodophenylpentadecanoic acid (IPPA) imaging to detect myocardial viability in patients with left ventricular (LV) dysfunction caused by coronary artery disease. Serial 180-degree single-photon emission computed tomographic (SPECT) images (five sets, 8 minutes each) were obtained starting 4 minutes after injection of 2 to 6 mCi 123I at rest in 21 patients with LV dysfunction (ejection fraction [EF] 34% +/- 11%). The segmental uptake was compared with that of rest-redistribution 201Tl images (20 segments/study). The number of perfusion defects (reversible and fixed) was similar by IPPA and thallium (11 +/- 5 vs 10 +/- 5 segments/patient; difference not significant). There was agreement between IPPA and thallium for presence or absence (kappa = 0.78 +/- 0.03) and nature (reversible, mild fixed, or severe fixed) of perfusion defects (kappa = 0.54 +/- 0.04). However, there were more reversible IPPA defects than reversible thallium defects (7 +/- 4 vs 3 +/- 4 segments/patient; p = 0.001). In 14 patients the EF (by gated pool imaging) improved after coronary revascularization from 33% +/- 11% to 39% +/- 12% (p = 0.002). The number of reversible IPPA defects was greater in the seven patients who had improvement in EF than in the patients without such improvement (10 +/- 4 vs 5 +/- 4 segments/patient; p = 0.075). 123I-labeled IPPA SPECT imaging is a promising new technique for assessment of viability. Reversible defects predict recovery of LV dysfunction after coronary revascularization.
Takabayashi, Takeshi; Mochizuki, Toshiaki; Otani, Norio; Nishiyama, Kei; Ishimatsu, Shinichi
2014-12-01
The prevalence of anisakiasis is rare in the United States and Europe compared with that in Japan, with few reports of its presentation in the emergency department (ED). This study describes the clinical, hematologic, computed tomographic (CT) characteristics, and treatment in gastric and small intestinal anisakiasis patients in the ED. We retrospectively reviewed the data of 83 consecutive anisakiasis presentations in our ED between 2003 and 2012. Gastric anisakiasis was endoscopically diagnosed with the Anisakis polypide. Small intestinal anisakiasis was diagnosed based on both hematologic (Anisakis antibody) and CT findings. Of the 83 cases, 39 had gastric anisakiasis and 44 had small intestinal anisakiasis based on our diagnostic criteria. Although all patients had abdominal pain, the gastric anisakiasis group developed symptoms significantly earlier (peaking within 6 hours) than the small intestinal anisakiasis group (peaking within 48 hours), and fewer patients with gastric anisakiasis needed admission therapy (5% vs 57%, P<.01). All patients in the gastric and 40 (91%) in the small intestinal anisakiasis group had a history of raw seafood ingestion. Computed tomographic findings revealed edematous wall thickening in all patients, and ascites and phlegmon of the mesenteric fat were more frequently observed in the small intestinal anisakiasis group. In the ED, early and accurate diagnosis of anisakiasis is important to treat and explain to the patient, and diagnosis can be facilitated by a history of raw seafood ingestion, evaluation of the time-to-symptom development, and classic CT findings. Copyright © 2014 Elsevier Inc. All rights reserved.
Numerical study on simultaneous emission and transmission tomography in the MRI framework
NASA Astrophysics Data System (ADS)
Gjesteby, Lars; Cong, Wenxiang; Wang, Ge
2017-09-01
Multi-modality imaging methods are instrumental for advanced diagnosis and therapy. Specifically, a hybrid system that combines computed tomography (CT), nuclear imaging, and magnetic resonance imaging (MRI) will be a Holy Grail of medical imaging, delivering complementary structural/morphological, functional, and molecular information for precision medicine. A novel imaging method was recently demonstrated that takes advantage of radiotracer polarization to combine MRI principles with nuclear imaging. This approach allows the concentration of a polarized Υ-ray emitting radioisotope to be imaged with MRI resolution potentially outperforming the standard nuclear imaging mode at a sensitivity significantly higher than that of MRI. In our work, we propose to acquire MRI-modulated nuclear data for simultaneous image reconstruction of both emission and transmission parameters, suggesting the potential for simultaneous CT-SPECT-MRI. The synchronized diverse datasets allow excellent spatiotemporal registration and unique insight into physiological and pathological features. Here we describe the methodology involving the system design with emphasis on the formulation for tomographic images, even when significant radiotracer signals are limited to a region of interest (ROI). Initial numerical results demonstrate the feasibility of our approach for reconstructing concentration and attenuation images through a head phantom with various radio-labeled ROIs. Additional considerations regarding the radioisotope characteristics are also discussed.
Advantages of semiconductor CZT for medical imaging
NASA Astrophysics Data System (ADS)
Wagenaar, Douglas J.; Parnham, Kevin; Sundal, Bjorn; Maehlum, Gunnar; Chowdhury, Samir; Meier, Dirk; Vandehei, Thor; Szawlowski, Marek; Patt, Bradley E.
2007-09-01
Cadmium zinc telluride (CdZnTe, or CZT) is a room-temperature semiconductor radiation detector that has been developed in recent years for a variety of applications. CZT has been investigated for many potential uses in medical imaging, especially in the field of single photon emission computed tomography (SPECT). CZT can also be used in positron emission tomography (PET) as well as photon-counting and integration-mode x-ray radiography and computed tomography (CT). The principal advantages of CZT are 1) direct conversion of x-ray or gamma-ray energy into electron-hole pairs; 2) energy resolution; 3) high spatial resolution and hence high space-bandwidth product; 4) room temperature operation, stable performance, high density, and small volume; 5) depth-of-interaction (DOI) available through signal processing. These advantages will be described in detail with examples from our own CZT systems. The ability to operate at room temperature, combined with DOI and very small pixels, make the use of multiple, stationary CZT "mini-gamma cameras" a realistic alternative to today's large Anger-type cameras that require motion to obtain tomographic sampling. The compatibility of CZT with Magnetic Resonance Imaging (MRI)-fields is demonstrated for a new type of multi-modality medical imaging, namely SPECT/MRI. For pre-clinical (i.e., laboratory animal) imaging, the advantages of CZT lie in spatial and energy resolution, small volume, automated quality control, and the potential for DOI for parallax removal in pinhole imaging. For clinical imaging, the imaging of radiographically dense breasts with CZT enables scatter rejection and hence improved contrast. Examples of clinical breast images with a dual-head CZT system are shown.
Field-portable lensfree tomographic microscope.
Isikman, Serhan O; Bishara, Waheb; Sikora, Uzair; Yaglidere, Oguzhan; Yeah, John; Ozcan, Aydogan
2011-07-07
We present a field-portable lensfree tomographic microscope, which can achieve sectional imaging of a large volume (∼20 mm(3)) on a chip with an axial resolution of <7 μm. In this compact tomographic imaging platform (weighing only ∼110 grams), 24 light-emitting diodes (LEDs) that are each butt-coupled to a fibre-optic waveguide are controlled through a cost-effective micro-processor to sequentially illuminate the sample from different angles to record lensfree holograms of the sample that is placed on the top of a digital sensor array. In order to generate pixel super-resolved (SR) lensfree holograms and hence digitally improve the achievable lateral resolution, multiple sub-pixel shifted holograms are recorded at each illumination angle by electromagnetically actuating the fibre-optic waveguides using compact coils and magnets. These SR projection holograms obtained over an angular range of ±50° are rapidly reconstructed to yield projection images of the sample, which can then be back-projected to compute tomograms of the objects on the sensor-chip. The performance of this compact and light-weight lensfree tomographic microscope is validated by imaging micro-beads of different dimensions as well as a Hymenolepis nana egg, which is an infectious parasitic flatworm. Achieving a decent three-dimensional spatial resolution, this field-portable on-chip optical tomographic microscope might provide a useful toolset for telemedicine and high-throughput imaging applications in resource-poor settings. This journal is © The Royal Society of Chemistry 2011
DOE Office of Scientific and Technical Information (OSTI.GOV)
Potchen, E.J.; Harris, G.I.; Gift, D.A. Reinhard, D.K.
Results are reported of the final phase of the study effort generally titled Evaluative Studies in Nuclear Medicine Research. The previous work is reviewed and extended to an assessment providing perspectives on medical applications of positron emission tomographic (PET) systems, their technological context, and the related economic and marketing environment. Methodologies developed and used in earlier phases of the study were continued, but specifically extended to include solicitation of opinion from commercial organizations deemed to be potential developers, manufacturers and marketers of PET systems. Several factors which influence the demand for clinical uses of PET are evaluated and discussed. Themore » recent Federal funding of applied research with PET systems is found to be a necessary and encouraging event toward a determination that PET either is a powerful research tool limited to research, or whether it also presents major clinical utility. A comprehensive, updated bibliography of current literature related to the development, applications and economic considerations of PET technology is appended.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Silverman, I.E.; Zeit, R.M.; Von Feldt, J.M.
1994-05-01
Systemic Lupus Erythematosis (SLE) commonly causes significant neuropsychiatric disorders. The purpose of this study was to review the brain SPECT studies of SLE patients with clinical evidence of CNS involvement and determine whether there is a correlation between the findings on SPECT images and the clinical manifestations of this serious phase of the disease. We enrolled 19 SLE patients and 12 normal controls in this study. The level of each patient`s disease activity was determined by the SLE Disease Activity Index (SLEDAI), an established method of scoring disease severity which is heavily weighted toward neuropsychiatric symptomatology, for 15 of themore » 19 SLE patients. The SLEDAI was calculated within a 10 day window of the date when the SPECT scan was obtained. SPECT scans were performed 30 minutes following the intravenous administration of 99mTc-HMPAO. Results are discussed.« less
Dushaw, Brian D; Sagen, Hanne
2017-12-01
Ocean acoustic tomography depends on a suitable reference ocean environment with which to set the basic parameters of the inverse problem. Some inverse problems may require a reference ocean that includes the small-scale variations from internal waves, small mesoscale, or spice. Tomographic inversions that employ data of stable shadow zone arrivals, such as those that have been observed in the North Pacific and Canary Basin, are an example. Estimating temperature from the unique acoustic data that have been obtained in Fram Strait is another example. The addition of small-scale variability to augment a smooth reference ocean is essential to understanding the acoustic forward problem in these cases. Rather than a hindrance, the stochastic influences of the small scale can be exploited to obtain accurate inverse estimates. Inverse solutions are readily obtained, and they give computed arrival patterns that matched the observations. The approach is not ad hoc, but universal, and it has allowed inverse estimates for ocean temperature variations in Fram Strait to be readily computed on several acoustic paths for which tomographic data were obtained.
Steady shape analysis of tomographic pumping tests for characterization of aquifer heterogeneities
Bohling, Geoffrey C.; Zhan, Xiaoyong; Butler, James J.; Zheng, Li
2002-01-01
Hydraulic tomography, a procedure involving the performance of a suite of pumping tests in a tomographic format, provides information about variations in hydraulic conductivity at a level of detail not obtainable with traditional well tests. However, analysis of transient data from such a suite of pumping tests represents a substantial computational burden. Although steady state responses can be analyzed to reduce this computational burden significantly, the time required to reach steady state will often be too long for practical applications of the tomography concept. In addition, uncertainty regarding the mechanisms driving the system to steady state can propagate to adversely impact the resulting hydraulic conductivity estimates. These disadvantages of a steady state analysis can be overcome by exploiting the simplifications possible under the steady shape flow regime. At steady shape conditions, drawdown varies with time but the hydraulic gradient does not. Thus transient data can be analyzed with the computational efficiency of a steady state model. In this study, we demonstrate the value of the steady shape concept for inversion of hydraulic tomography data and investigate its robustness with respect to improperly specified boundary conditions.
NASA Astrophysics Data System (ADS)
Moskal, P.; Alfs, D.; Bednarski, T.; Białas, P.; Curceanu, C.; Czerwiński, E.; Dulski, K.; Gajos, A.; Głowacz, B.; Gupta-Sharma, N.; Gorgol, M.; Hiesmayr, B. C.; Jasińska, B.; Kamińska, D.; Khreptak, O.; Korcyl, G.; Kowalski, P.; Krzemień, W.; Krawczyk, N.; Kubicz, E.; Mohammed, M.; Niedźwiecki, Sz.; Pawlik-Niedńwiecka, M.; Raczyński, L.; Rudy, Z.; Silarski, M.; Smyrski, J.; Wieczorek, A.; Wiślicki, W.; Zgardzińska, B.; Zieliński, M.
2016-11-01
Discrete symmetries such as parity (P), charge-conjugation (C) and time reversal (T) are of fundamental importance in physics and cosmology. Breaking of charge conjugation symmetry (C) and its combination with parity (CP) constitute necessary conditions for the existence of the asymmetry between matter and antimatter in the observed Universe. The presently known sources of discrete symmetries violations can account for only a tiny fraction of the excess of matter over antimatter. So far CP and T symmetries violations were observed only for systems involving quarks and they were never reported for the purely leptonic objects. In this article we describe briefly an experimental proposal for the test of discrete symmetries in the decays of positronium atom which is made exclusively of leptons. The experiments are conducted by means of the Jagiellonian Positron Emission Tomograph (J-PET) which is constructed from strips of plastic scintillators enabling registration of photons from the positronium annihilation. J-PET tomograph together with the positronium target system enable to measure expectation values for the discrete symmetries odd operators constructed from (i) spin vector of the ortho-positronium atom, (ii) momentum vectors of photons originating from the decay of positronium, and (iii) linear polarization direction of annihilation photons. Linearly polarized positronium will be produced in the highly porous aerogel or polymer targets, exploiting longitudinally polarized positrons emitted by the sodium 22Na isotope. Information about the polarization vector of orthopositronium will be available on the event by event basis and will be reconstructed from the known position of the positron source and the reconstructed position of the orthopositronium annihilation. In 2016 the first tests and calibration runs are planned, and the data collection with high statistics will commence in the year 2017.
HFSB-seeding for large-scale tomographic PIV in wind tunnels
NASA Astrophysics Data System (ADS)
Caridi, Giuseppe Carlo Alp; Ragni, Daniele; Sciacchitano, Andrea; Scarano, Fulvio
2016-12-01
A new system for large-scale tomographic particle image velocimetry in low-speed wind tunnels is presented. The system relies upon the use of sub-millimetre helium-filled soap bubbles as flow tracers, which scatter light with intensity several orders of magnitude higher than micron-sized droplets. With respect to a single bubble generator, the system increases the rate of bubbles emission by means of transient accumulation and rapid release. The governing parameters of the system are identified and discussed, namely the bubbles production rate, the accumulation and release times, the size of the bubble injector and its location with respect to the wind tunnel contraction. The relations between the above parameters, the resulting spatial concentration of tracers and measurement of dynamic spatial range are obtained and discussed. Large-scale experiments are carried out in a large low-speed wind tunnel with 2.85 × 2.85 m2 test section, where a vertical axis wind turbine of 1 m diameter is operated. Time-resolved tomographic PIV measurements are taken over a measurement volume of 40 × 20 × 15 cm3, allowing the quantitative analysis of the tip-vortex structure and dynamical evolution.
Imaging open-path Fourier transform infrared spectrometer for 3D cloud profiling
NASA Astrophysics Data System (ADS)
Rentz Dupuis, Julia; Mansur, David J.; Vaillancourt, Robert; Carlson, David; Evans, Thomas; Schundler, Elizabeth; Todd, Lori; Mottus, Kathleen
2009-05-01
OPTRA is developing an imaging open-path Fourier transform infrared (I-OP-FTIR) spectrometer for 3D profiling of chemical and biological agent simulant plumes released into test ranges and chambers. An array of I-OP-FTIR instruments positioned around the perimeter of the test site, in concert with advanced spectroscopic algorithms, enables real time tomographic reconstruction of the plume. The approach is intended as a referee measurement for test ranges and chambers. This Small Business Technology Transfer (STTR) effort combines the instrumentation and spectroscopic capabilities of OPTRA, Inc. with the computed tomographic expertise of the University of North Carolina, Chapel Hill.
DOE R&D Accomplishments Database
Hansche, B. D.
1983-01-01
Computed tomography (CT) is a relatively new radiographic technique which has become widely used in the medical field, where it is better known as computerized axial tomographic (CAT) scanning. This technique is also being adopted by the industrial radiographic community, although the greater range of densities, variation in samples sizes, plus possible requirement for finer resolution make it difficult to duplicate the excellent results that the medical scanners have achieved.
Including Short Period Constraints In the Construction of Full Waveform Tomographic Models
NASA Astrophysics Data System (ADS)
Roy, C.; Calo, M.; Bodin, T.; Romanowicz, B. A.
2015-12-01
Thanks to the introduction of the Spectral Element Method (SEM) in seismology, which allows accurate computation of the seismic wavefield in complex media, the resolution of regional and global tomographic models has improved in recent years. However, due to computational costs, only long period waveforms are considered, and only long wavelength structure can be constrained. Thus, the resulting 3D models are smooth, and only represent a small volumetric perturbation around a smooth reference model that does not include upper-mantle discontinuities (e.g. MLD, LAB). Extending the computations to shorter periods, necessary for the resolution of smaller scale features, is computationally challenging. In order to overcome these limitations and to account for layered structure in the upper mantle in our full waveform tomography, we include information provided by short period seismic observables (receiver functions and surface wave dispersion), sensitive to sharp boundaries and anisotropic structure respectively. In a first step, receiver functions and dispersion curves are used to generate a number of 1D radially anisotropic shear velocity profiles using a trans-dimensional Markov-chain Monte Carlo (MCMC) algorithm. These 1D profiles include both isotropic and anisotropic discontinuities in the upper mantle (above 300 km depth) beneath selected stationsand are then used to build a 3D starting model for the full waveform tomographic inversion. This model is built after 1) interpolation between the available 1D profiles, and 2) homogeneization of the layered 1D models to obtain an equivalent smooth 3D starting model in the period range of interest for waveform inversion. The waveforms used in the inversion are collected for paths contained in the region of study and filtered at periods longer than 40s. We use the spectral element code "RegSEM" (Cupillard et al., 2012) for forward computations and a quasi-Newton inversion approach in which kernels are computed using normal mode perturbation theory. We present here the first reults of such an approach after successive iterations of a full waveform tomography of the North American continent.
Development of the two Korean adult tomographic computational phantoms for organ dosimetry
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, Choonsik; Lee, Choonik; Park, Sang-Hyun
2006-02-15
Following the previously developed Korean tomographic phantom, KORMAN, two additional whole-body tomographic phantoms of Korean adult males were developed from magnetic resonance (MR) and computed tomography (CT) images, respectively. Two healthy male volunteers, whose body dimensions were fairly representative of the average Korean adult male, were recruited and scanned for phantom development. Contiguous whole body MR images were obtained from one subject exclusive of the arms, while whole-body CT images were acquired from the second individual. A total of 29 organs and tissues and 19 skeletal sites were segmented via image manipulation techniques such as gray-level thresholding, region growing, andmore » manual drawing, in which each of segmented image slice was subsequently reviewed by an experienced radiologist for anatomical accuracy. The resulting phantoms, the MR-based KTMAN-1 (Korean Typical MAN-1) and the CT-based KTMAN-2 (Korean Typical MAN-2), consist of 300x150x344 voxels with a voxel resolution of 2x2x5 mm{sup 3} for both phantoms. Masses of segmented organs and tissues were calculated as the product of a nominal reference density, the prevoxel volume, and the cumulative number of voxels defining each organs or tissue. These organs masses were then compared with those of both the Asian and the ICRP reference adult male. Organ masses within both KTMAN-1 and KTMAN-2 showed differences within 40% of Asian and ICRP reference values, with the exception of the skin, gall bladder, and pancreas which displayed larger differences. The resulting three-dimensional binary file was ported to the Monte Carlo code MCNPX2.4 to calculate organ doses following external irradiation for illustrative purposes. Colon, lung, liver, and stomach absorbed doses, as well as the effective dose, for idealized photon irradiation geometries (anterior-posterior and right lateral) were determined, and then compared with data from two other tomographic phantoms (Asian and Caucasian), and stylized ORNL phantom. The armless KTMAN-1 can be applied to dosimetry for computed tomography or lateral x-ray examination, while the whole body KTMAN-2 can be used for radiation protection dosimetry.« less
Tucker, Melissa D.; Sellon, Rance K.; Tucker, Russell L.; Wills, Tamara B.; Simonsen, Andrea; Maggi, Ricardo G.; Breitschwerdt, Edward B.
2014-01-01
This report describes a 2-year-old collie dog with pulmonary nodules, visualized by computed tomographic (CT) scan, with evidence of Bartonella henselae bacteremia and pyogranulomatous lymphadenitis. Clinical signs resolved with antimicrobial therapy. PMID:25320386
Procedures for Geometric Data Reduction in Solid Log Modelling
Luis G. Occeña; Wenzhen Chen; Daniel L. Schmoldt
1995-01-01
One of the difficulties in solid log modelling is working with huge data sets, such as those that come from computed axial tomographic imaging. Algorithmic procedures are described in this paper that have successfully reduced data without sacrificing modelling integrity.
Gupta, Rajiv; Jones, Stephen E; Mooyaart, Eline A Q; Pomerantz, Stuart R
2006-06-01
The development of multidetector row computed tomography (MDCT) now permits visualization of the entire vascular tree that is relevant for the management of stroke within 15 seconds. Advances in MDCT have brought computed tomography angiography (CTA) to the frontline in evaluation of stroke. CTA is a rapid and noninvasive modality for evaluating the neurovasculature. This article describes the role of CTA in the management of stroke. Fundamentals of contrast delivery, common pathologic findings, artifacts, and pitfalls in CTA interpretation are discussed.
Corkscrew basilar artery as an incidental finding on neuroimaging.
Moser, Franklin G; Sarnat, Harvey B; Maya, Marcel M; Menkes, John H
2007-11-01
We report on an incidental finding of a markedly tortuous basilar artery in a 6-year-old child. The child underwent a computed tomography scan for minor head trauma, and a basilar artery abnormality was discovered, i.e., a markedly tortuous basilar artery without any other congenital anomalies or syndromes. After an exhaustive workup including computed tomography, magnetic resonance imaging, magnetic resonance angiography, computed tomographic angiography, and genetic tests for associated genetic syndromes, no intervention was deemed necessary. The embryonic etiology and clinical implications are discussed.
Scarmeas, Nikolaos; Zarahn, Eric; Anderson, Karen E.; Honig, Lawrence S.; Park, Aileen; Hilton, John; Flynn, Joseph; Sackeim, Harold A.; Stern, Yaakov
2011-01-01
Background Cognitive reserve (CR) is the ability of an individual to cope with advancing brain pathological abnormalities so that he or she remains free of symptoms. Epidemiological data and evidence from positron emission tomography suggest that it may be mediated through education or IQ. Objective To investigate CR-mediated differential brain activation in Alzheimer disease (AD) subjects compared with healthy elderly persons. Participants Using radioactive water positron emission tomography, we scanned 12 AD patients and 17 healthy elderly persons while performing a serial recognition memory task for nonverbalizable shapes under 2 conditions: low demand, in which one shape was presented in each study trial, and titrated demand, in which the study list length was adjusted so that each subject recognized shapes at approximately 75% accuracy. Positron emission tomographic scan acquisition included the encoding and recognition phases. A CR factor score that summarized years of education, National Adult Reading Test estimated IQ, and Wechsler Adult Intelligence Scale–Revised vocabulary subtest score (explaining 71% of the total variance) was used as an index of CR. Voxel-wise, multiple regression analyses were performed with the “activation” difference (titrated demand–low demand) as the dependent variables and the CR factor score as the independent one. Brain regions where regression slopes differed between the 2 groups were identified. Results The slopes were significantly more positive for the AD patients in the left precentral gyrus and in the left hippocampus and significantly more negative in the right fusiform, right middle occipital, left superior occipital, and left middle temporal gyri. Conclusion Brain regions where systematic relationships (slopes) between subjects’ education-IQ and brain activation differ as a function of disease status may mediate the differential ability to cope with (ie, delay or modify) clinical manifestations of AD. PMID:14732623
NASA Astrophysics Data System (ADS)
Agafonov, M. I.; Karitskaya, E. A.; Sharova, O. I.; Bochkarev, N. G.; Zharikov, S. V.; Butenko, G. Z.; Bondar', A. V.; Bubukin, I. T.
2018-03-01
This is the second paper in a series dedicated to studies of the X-ray binary Cyg X-1 in the HeII λ 4686 Å line using 3D Doppler tomography. A detailed analysis of the tomogram constructed has made it possible for the first time to obtain information about the motions of gaseous flows including all three velocity components. The observations were obtained in June 2007 at the Terskol Branch of the Institute of Astronomy (Russia) and the National Astronomical Observatory of Mexico. The correctness of the tomographic results and their discussion is analyzed. The results are compared with a 2D Doppler tomogram reconstruction. Model-atmosphere computations of HeII λ 4686 Å line profiles are used to estimate the influence of absorption features of the Osupergiant on the emission structure in the tomogram. The correctness of the 3D solutions is confirmed by the good agreement between the original sequence of spectral data and a control data set computed using the constructed 3D Doppler tomogram. Tomograms constructed using the data of each of the two observatories are compared. The results of the reconstruction for inclinations of the system of 40° and 45° essentially coincide. The maximum absorption (corresponding to the O supergiant) and emission structural features in the 3D tomogram are located in its central ( V x , V y ) section, where the velocity component perpendicular to the orbital plane V z is zero. The emission is generated mainly in the outer part of the accretion structure, close to the supergiant. A gaseous stream from the Lagrangian point L1 with its motion close to the orbital plane can be distinguished. Its maximum velocity reaches 800 km/s. The identification of an emission structure with V z 300 km/s and with V x , V y in the velocity interval corresponding to the donor star was unexpected. Its presence may indicate, for example, an outflow of matter from a magnetic pole of the supergiant.
Filpo-Perez, Carolina; Bramante, Clovis Monteiro; Villas-Boas, Marcelo Haas; Húngaro Duarte, Marco Antonio; Versiani, Marco Aurélio; Ordinola-Zapata, Ronald
2015-02-01
The aim of this study was to evaluate the morphologic aspects of the root canal anatomy of the distal root of a mandibular first molar using micro-computed tomographic analysis. One-hundred distal roots of mandibular first molars were scanned using a micro-computed tomographic device at an isotropic resolution of 19.6 μm. The percentage frequency distribution of the morphologic configuration of the root canal was performed according to the Vertucci classification system. Two-dimensional parameters (area, perimeter, roundness, aspect ratio, and major and minor diameters) and the cross-sectional shape of the root canal were analyzed in the apical third at every 1-mm interval from the main apical foramen in roots presenting Vertucci types I and II configurations (n = 79). Data were statistically compared using the Kruskal-Wallis and Dunn tests with a significance level set at 5%. Seventy-six percent of the distal roots had a single root canal. Two, three, and four canals were found in 13%, 8%, and 3% of the sample, respectively. In 13 specimens, the configuration of the root canal did not fit into Vertucci's classification. Overall, 2-dimensional parameter values significantly increased at the 3-mm level (P < .05). The prevalence of oval canals was higher at the 1-mm level and decreased at the 5-mm level in which long oval and flattened canals were more prevalent. The distal roots of the mandibular first molars showed a high prevalence of single root canals. The prevalence of long oval and flattened canals increased in the coronal direction. In 13% of the samples, canal configurations that were not included in Vertucci's configuration system were found. Copyright © 2015 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Bühler, M; Fürst, A; Lewis, F I; Kummer, M; Ohlerth, S
2014-07-01
Computed tomographic (CT) studies evaluating the relevance of individual CT features of apical infection in maxillary cheek teeth are lacking. To study the prevalence and relationship of single CT features in horses with and without clinical evidence of apical infection in maxillary cheek teeth. Retrospective case-control study. Multislice CT scans of the head of 49 horses were evaluated retrospectively. Changes of the infundibulum, pulp, root, lamina dura, periodontal space and alveolar bone in maxillary cheek teeth were recorded. Single CT changes were much more prevalent in the 28 horses with clinical signs. However, infundibular changes and a nondetectable lamina dura were also common in the 21 horses without clinical evidence of apical infection. Computed tomographic abnormalities of the pulp, root, periapical bone and periodontal space and the presence of a tooth fracture were significantly related. Infundibular changes were not associated with other CT signs of apical infection. Although nondetectable lamina dura was the most frequent CT change in all teeth in both studied groups, it was most commonly a solitary feature in otherwise normal teeth. Apical infections, defined as ≥3 CT changes, occurred mainly in the 108/208, 109/209 and 110/210 (Triadan numbers) and were found only in horses with clinical evidence of apical infection, except in one horse without clinical signs that had one affected root. Combined CT changes of the pulp, root, lamina dura, periapical bone and periodontal space and the presence of a tooth fracture appear to be reliable features to diagnose apical infection in maxillary cheek teeth. As a solitary feature, a nondetectable lamina dura should be interpreted cautiously and may even be considered normal due to its minor thickness and/or too low resolution of the imaging modality. © 2013 EVJ Ltd.
de Oliveira, Bruna Paloma; Câmara, Andréa Cruz; Duarte, Daniel Amancio; Heck, Richard John; Antonino, Antonio Celso Dantas; Aguiar, Carlos Menezes
2017-07-01
This study aimed to compare apical microcrack formation after root canal shaping by hand, rotary, and reciprocating files at different working lengths using micro-computed tomographic analysis. Sixty mandibular incisors were randomly divided into 6 experimental groups (n = 10) according to the systems and working lengths used for the root canal preparation: ProTaper Universal for Hand Use (Dentsply Maillefer, Ballaigues, Switzerland), HyFlex CM (Coltene-Whaledent, Allstetten, Switzerland), and Reciproc (VDW, Munich, Germany) files working at the apical foramen (AF) and 1 mm short of the AF (AF - 1 mm). The teeth were imaged with micro-computed tomographic scanning at an isotropic resolution of 14 μm before and after root canal preparation, and the cross-sectional images generated were assessed to detect microcracks in the apical portion of the roots. Overall, 17 (28.3%) specimens presented microcracks before instrumentation. Apical microcracks were present in 1 (ProTaper Universal for Hand Use), 3 (Hyflex CM), and 2 (Reciproc) specimens when the instrumentation terminated at the AF. When instrumentation was terminated at AF - 1 mm, apical microcracks were detected in 3 (ProTaper Universal for Hand Use) and 4 (Hyflex CM and Reciproc) specimens. All these microcracks detected after root canal preparation were already present before instrumentation, and no new apical microcrack was visualized. For all groups, the number of slices presenting microcracks after root canal preparation was the same as before canal preparation. Root canal shaping with ProTaper Universal for Hand Use, HyFlex CM, and Reciproc systems, regardless of the working length, did not produce apical microcracks. Copyright © 2017 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Hecht, Harvey S; Narula, Jagat; Fearon, William F
2016-07-08
Invasive fractional flow reserve (FFR) is now the gold standard for intervention. Noninvasive functional imaging analyses derived from coronary computed tomographic angiography (CTA) offer alternatives for evaluating lesion-specific ischemia. CT-FFR, CT myocardial perfusion imaging, and transluminal attenuation gradient/corrected contrast opacification have been studied using invasive FFR as the gold standard. CT-FFR has demonstrated significant improvement in specificity and positive predictive value compared with CTA alone for predicting FFR of ≤0.80, as well as decreasing the frequency of nonobstructive invasive coronary angiography. High-risk plaque characteristics have also been strongly implicated in abnormal FFR. Myocardial computed tomographic perfusion is an alternative method with promising results; it involves more radiation and contrast. Transluminal attenuation gradient/corrected contrast opacification is more controversial and may be more related to vessel diameter than stenosis. Important considerations remain: (1) improvement of CTA quality to decrease unevaluable studies, (2) is the diagnostic accuracy of CT-FFR sufficient? (3) can CT-FFR guide intervention without invasive FFR confirmation? (4) what are the long-term outcomes of CT-FFR-guided treatment and how do they compare with other functional imaging-guided paradigms? (5) what degree of stenosis on CTA warrants CT-FFR? (6) how should high-risk plaque be incorporated into treatment decisions? (7) how will CT-FFR influence other functional imaging test utilization, and what will be the effect on the practice of cardiology? (8) will a workstation-based CT-FFR be mandatory? Rapid progress to date suggests that CTA-based lesion-specific ischemia will be the gatekeeper to the cardiac catheterization laboratory and will transform the world of intervention. © 2016 American Heart Association, Inc.
Bayram, H Melike; Bayram, Emre; Ocak, Mert; Uygun, Ahmet Demirhan; Celik, Hakan Hamdi
2017-07-01
The aim of the present study was to evaluate the frequency of dentinal microcracks observed after root canal preparation with ProTaper Universal (PTU; Dentsply Tulsa Dental Specialties, Tulsa, OK), ProTaper Gold (PTG; Dentsply Tulsa Dental Specialties), Self-Adjusting File (SAF; ReDent Nova, Ra'anana, Israel), and XP-endo Shaper (XP; FKG Dentaire, La Chaux-de-Fonds, Switzerland) instruments using micro-computed tomographic (CT) analysis. Forty extracted human mandibular premolars having single-canal and straight root were randomly assigned to 4 experimental groups (n = 10) according to the different nickel-titanium systems used for root canal preparation: PTU, PTG, SAF, and XP. In the SAF and XP groups, the canals were first prepared with a K-file until #25 at the working length, and then the SAF or XP files were used. The specimens were scanned using high-resolution micro-computed tomographic imaging before and after root canal preparation. Afterward, preoperative and postoperative cross-sectional images of the teeth were screened to identify the presence of dentinal defects. For each group, the number of microcracks was determined as a percentage rate. The McNemar test was used to determine significant differences before and after instrumentation. The level of significance was set at P ≤ .05. The PTU system significantly increased the percentage rate of microcracks compared with preoperative specimens (P < .05). No new dentinal microcracks were observed in the PTG, SAF, or XP groups. Root canal preparations with the PTG, SAF, and XP systems did not induce the formation of new dentinal microcracks on straight root canals of mandibular premolars. Copyright © 2017 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Nakanishi, Rine; Baskaran, Lohendran; Gransar, Heidi; Budoff, Matthew J; Achenbach, Stephan; Al-Mallah, Mouaz; Cademartiri, Filippo; Callister, Tracy Q; Chang, Hyuk-Jae; Chinnaiyan, Kavitha; Chow, Benjamin J W; DeLago, Augustin; Hadamitzky, Martin; Hausleiter, Joerg; Cury, Ricardo; Feuchtner, Gudrun; Kim, Yong-Jin; Leipsic, Jonathon; Kaufmann, Philipp A; Maffei, Erica; Raff, Gilbert; Shaw, Leslee J; Villines, Todd C; Dunning, Allison; Marques, Hugo; Pontone, Gianluca; Andreini, Daniele; Rubinshtein, Ronen; Bax, Jeroen; Jones, Erica; Hindoyan, Niree; Gomez, Millie; Lin, Fay Y; Min, James K; Berman, Daniel S
2017-08-01
Hypertension is an atherosclerosis factor and is associated with cardiovascular risk. We investigated the relationship between hypertension and the presence, extent, and severity of coronary atherosclerosis in coronary computed tomographic angiography and cardiac events risk. Of 17 181 patients enrolled in the CONFIRM registry (Coronary CT Angiography Evaluation for Clinical Outcomes: An International Multicenter Registry) who underwent ≥64-detector row coronary computed tomographic angiography, we identified 14 803 patients without known coronary artery disease. Of these, 1434 hypertensive patients were matched to 1434 patients without hypertension. Major adverse cardiac events risk of hypertension and non-hypertensive patients was evaluated with Cox proportional hazards models. The prognostic associations between hypertension and no-hypertension with increasing degree of coronary stenosis severity (nonobstructive or obstructive ≥50%) and extent of coronary artery disease (segment involvement score of 1-5, >5) was also assessed. Hypertension patients less commonly had no coronary atherosclerosis and more commonly had nonobstructive and 1-, 2-, and 3-vessel disease than the no-hypertension group. During a mean follow-up of 5.2±1.2 years, 180 patients experienced cardiac events, with 104 (2.0%) occurring in the hypertension group and 76 (1.5%) occurring in the no-hypertension group (hazard ratios, 1.4; 95% confidence intervals, 1.0-1.9). Compared with no-hypertension patients without coronary atherosclerosis, hypertension patients with no coronary atherosclerosis and obstructive coronary disease tended to have higher risk of cardiac events. Similar trends were observed with respect to extent of coronary artery disease. Compared with no-hypertension patients, hypertensive patients have increased presence, extent, and severity of coronary atherosclerosis and tend to have an increase in major adverse cardiac events. © 2017 American Heart Association, Inc.
The Collaborative Seismic Earth Model Project
NASA Astrophysics Data System (ADS)
Fichtner, A.; van Herwaarden, D. P.; Afanasiev, M.
2017-12-01
We present the first generation of the Collaborative Seismic Earth Model (CSEM). This effort is intended to address grand challenges in tomography that currently inhibit imaging the Earth's interior across the seismically accessible scales: [1] For decades to come, computational resources will remain insufficient for the exploitation of the full observable seismic bandwidth. [2] With the man power of individual research groups, only small fractions of available waveform data can be incorporated into seismic tomographies. [3] The limited incorporation of prior knowledge on 3D structure leads to slow progress and inefficient use of resources. The CSEM is a multi-scale model of global 3D Earth structure that evolves continuously through successive regional refinements. Taking the current state of the CSEM as initial model, these refinements are contributed by external collaborators, and used to advance the CSEM to the next state. This mode of operation allows the CSEM to [1] harness the distributed man and computing power of the community, [2] to make consistent use of prior knowledge, and [3] to combine different tomographic techniques, needed to cover the seismic data bandwidth. Furthermore, the CSEM has the potential to serve as a unified and accessible representation of tomographic Earth models. Generation 1 comprises around 15 regional tomographic refinements, computed with full-waveform inversion. These include continental-scale mantle models of North America, Australasia, Europe and the South Atlantic, as well as detailed regional models of the crust beneath the Iberian Peninsula and western Turkey. A global-scale full-waveform inversion ensures that regional refinements are consistent with whole-Earth structure. This first generation will serve as the basis for further automation and methodological improvements concerning validation and uncertainty quantification.
Solving large tomographic linear systems: size reduction and error estimation
NASA Astrophysics Data System (ADS)
Voronin, Sergey; Mikesell, Dylan; Slezak, Inna; Nolet, Guust
2014-10-01
We present a new approach to reduce a sparse, linear system of equations associated with tomographic inverse problems. We begin by making a modification to the commonly used compressed sparse-row format, whereby our format is tailored to the sparse structure of finite-frequency (volume) sensitivity kernels in seismic tomography. Next, we cluster the sparse matrix rows to divide a large matrix into smaller subsets representing ray paths that are geographically close. Singular value decomposition of each subset allows us to project the data onto a subspace associated with the largest eigenvalues of the subset. After projection we reject those data that have a signal-to-noise ratio (SNR) below a chosen threshold. Clustering in this way assures that the sparse nature of the system is minimally affected by the projection. Moreover, our approach allows for a precise estimation of the noise affecting the data while also giving us the ability to identify outliers. We illustrate the method by reducing large matrices computed for global tomographic systems with cross-correlation body wave delays, as well as with surface wave phase velocity anomalies. For a massive matrix computed for 3.7 million Rayleigh wave phase velocity measurements, imposing a threshold of 1 for the SNR, we condensed the matrix size from 1103 to 63 Gbyte. For a global data set of multiple-frequency P wave delays from 60 well-distributed deep earthquakes we obtain a reduction to 5.9 per cent. This type of reduction allows one to avoid loss of information due to underparametrizing models. Alternatively, if data have to be rejected to fit the system into computer memory, it assures that the most important data are preserved.
Linear Optimization and Image Reconstruction
1994-06-01
final example is again a novel one. We formulate the problem of computer assisted tomographic ( CAT ) image reconstruction as a linear optimization...possibility that a patient, Fred, suffers from a brain tumor. Further, the physician opts to make use of the CAT (Computer Aided Tomography) scan device...and examine the inside of Fred’s head without exploratory surgery. The CAT scan machine works by projecting a finite number of X-rays of known
A Detailed Study of Sonar Tomographic Imaging
2013-08-01
BPA ) to form an object image. As the data is collected radially about the axis of rotation, one computation method computes an inverse Fourier...images are not quite as sharp. It is concluded UNCLASSIFIED iii DSTO–RR–0394 UNCLASSIFIED that polar BPA processing requires an appropriate choice of...attenuation factor to reduce the effect of the specular reflections, while for the 2DIFT BPA approach the degrading effect from these reflections is
Computed tomographic identification of calcified optic nerve drusen
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ramirez, H.; Blatt, E.S.; Hibri, N.S.
1983-07-01
Four cases of optic disk drusen were accurately diagnosed with orbital computed tomography (CT). The radiologist should be aware of the characteristic CT finding of discrete calcification within an otherwise normal optic disk. This benign process is easily differentiated from lesions such as calcific neoplastic processes of the posterior globe. CT identification of optic disk drusen is essential in the evaluation of visual field defects, migraine-like headaches, and pseudopapilledema.
Summers, Ronald M; Baecher, Nicolai; Yao, Jianhua; Liu, Jiamin; Pickhardt, Perry J; Choi, J Richard; Hill, Suvimol
2011-01-01
To show the feasibility of calculating the bone mineral density (BMD) from computed tomographic colonography (CTC) scans using fully automated software. Automated BMD measurement software was developed that measures the BMD of the first and second lumbar vertebrae on computed tomography and calculates the mean of the 2 values to provide a per patient BMD estimate. The software was validated in a reference population of 17 consecutive women who underwent quantitative computed tomography and in a population of 475 women from a consecutive series of asymptomatic patients enrolled in a CTC screening trial conducted at 3 medical centers. The mean (SD) BMD was 133.6 (34.6) mg/mL (95% confidence interval, 130.5-136.7; n = 475). In women aged 42 to 60 years (n = 316) and 61 to 79 years (n = 159), the mean (SD) BMDs were 143.1 (33.5) and 114.7 (28.3) mg/mL, respectively (P < 0.0001). Fully automated BMD measurements were reproducible for a given patient with 95% limits of agreement of -9.79 to 8.46 mg/mL for the mean difference between paired assessments on supine and prone CTC. Osteoporosis screening can be performed simultaneously with screening for colorectal polyps.
Moosavi Tayebi, Rohollah; Wirza, Rahmita; Sulaiman, Puteri S B; Dimon, Mohd Zamrin; Khalid, Fatimah; Al-Surmi, Aqeel; Mazaheri, Samaneh
2015-04-22
Computerized tomographic angiography (3D data representing the coronary arteries) and X-ray angiography (2D X-ray image sequences providing information about coronary arteries and their stenosis) are standard and popular assessment tools utilized for medical diagnosis of coronary artery diseases. At present, the results of both modalities are individually analyzed by specialists and it is difficult for them to mentally connect the details of these two techniques. The aim of this work is to assist medical diagnosis by providing specialists with the relationship between computerized tomographic angiography and X-ray angiography. In this study, coronary arteries from two modalities are registered in order to create a 3D reconstruction of the stenosis position. The proposed method starts with coronary artery segmentation and labeling for both modalities. Then, stenosis and relevant labeled artery in X-ray angiography image are marked by a specialist. Proper control points for the marked artery in both modalities are automatically detected and normalized. Then, a geometrical transformation function is computed using these control points. Finally, this function is utilized to register the marked artery from the X-ray angiography image on the computerized tomographic angiography and get the 3D position of the stenosis lesion. The result is a 3D informative model consisting of stenosis and coronary arteries' information from the X-ray angiography and computerized tomographic angiography modalities. The results of the proposed method for coronary artery segmentation, labeling and 3D reconstruction are evaluated and validated on the dataset containing both modalities. The advantage of this method is to aid specialists to determine a visual relationship between the correspondent coronary arteries from two modalities and also set up a connection between stenosis points from an X-ray angiography along with their 3D positions on the coronary arteries from computerized tomographic angiography. Moreover, another benefit of this work is that the medical acquisition standards remain unchanged, which means that no calibration in the acquisition devices is required. It can be applied on most computerized tomographic angiography and angiography devices.
Mouden, Mohamed; Rijkee, Karlijn S; Schreuder, Nanno; Timmer, Jorik R; Jager, Pieter L
2015-02-01
Proton-pump inhibitors (PPIs) induce potentially interfering stomach wall activity in single-photon emission computed tomography myocardial perfusion imaging (SPECT-MPI) with technetium-99m ((99m)Tc)-sestamibi. However, no data are available for (99m)Tc-tetrofosmin. We assessed the influence of prolonged (>2 weeks) PPI use on the stomach wall uptake of (99m)Tc-tetrofosmin in patients referred for stress MPI with a cadmium-zinc-telluride-based SPECT camera and its relation with dyspepsia symptoms. Consecutive patients (n=127) underwent a 1-day adenosine stress-first SPECT-MPI with (99m)Tc-tetrofosmin, of whom 54 (43%) patients had been on PPIs for more than 2 weeks. Stomach wall activity was identified on stress SPECT using computed tomographic attenuation maps and was scored using a four-point grading scale into clinically relevant (scores 2 or 3) or nonrelevant (scores 0 or 1).Patients on PPIs had stomach wall uptake more frequently as compared with patients not using PPIs (22 vs. 7%, P=0.017). Dyspepsia was similar in both groups. Prolonged use of PPIs is associated with stomach wall uptake of (99m)Tc-tetrofosmin in stress cadmium-zinc-telluride-SPECT images. Gastric symptoms were not associated with stomach wall uptake.
High resolution x-ray CMT: Reconstruction methods
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brown, J.K.
This paper qualitatively discusses the primary characteristics of methods for reconstructing tomographic images from a set of projections. These reconstruction methods can be categorized as either {open_quotes}analytic{close_quotes} or {open_quotes}iterative{close_quotes} techniques. Analytic algorithms are derived from the formal inversion of equations describing the imaging process, while iterative algorithms incorporate a model of the imaging process and provide a mechanism to iteratively improve image estimates. Analytic reconstruction algorithms are typically computationally more efficient than iterative methods; however, analytic algorithms are available for a relatively limited set of imaging geometries and situations. Thus, the framework of iterative reconstruction methods is better suited formore » high accuracy, tomographic reconstruction codes.« less
X-ray tomographic image magnification process, system and apparatus therefor
Kinney, J.H.; Bonse, U.K.; Johnson, Q.C.; Nichols, M.C.; Saroyan, R.A.; Massey, W.N.; Nusshardt, R.
1993-09-14
A computerized three-dimensional x-ray tomographic microscopy system is disclosed, comprising: (a) source means for providing a source of parallel x-ray beams, (b) staging means for staging and sequentially rotating a sample to be positioned in the path of the (c) x-ray image magnifier means positioned in the path of the beams downstream from the sample, (d) detecting means for detecting the beams after being passed through and magnified by the image magnifier means, and (e) computing means for analyzing values received from the detecting means, and converting the values into three-dimensional representations. Also disclosed is a process for magnifying an x-ray image, and apparatus therefor. 25 figures.
X-ray tomographic image magnification process, system and apparatus therefor
Kinney, John H.; Bonse, Ulrich K.; Johnson, Quintin C.; Nichols, Monte C.; Saroyan, Ralph A.; Massey, Warren N.; Nusshardt, Rudolph
1993-01-01
A computerized three-dimensional x-ray tomographic microscopy system is disclosed, comprising: a) source means for providing a source of parallel x-ray beams, b) staging means for staging and sequentially rotating a sample to be positioned in the path of the c) x-ray image magnifier means positioned in the path of the beams downstream from the sample, d) detecting means for detecting the beams after being passed through and magnified by the image magnifier means, and e) computing means for analyzing values received from the detecting means, and converting the values into three-dimensional representations. Also disclosed is a process for magnifying an x-ray image, and apparatus therefor.
Childhood Psychosis and Computed Tomographic Brain Scan Findings.
ERIC Educational Resources Information Center
Gillberg, Christopher; Svendsen, Pal
1983-01-01
Computerized tomography (CT) of the brain was used to examine 27 infantile autistic children, 9 children with other kinds of childhood psychoses, 23 children with mental retardation, and 16 normal children. Gross abnormalities were seen in 26 percent of the autism cases. (Author/SEW)
Lee, Jun Ho; Choi, Hui-Chul; Kim, Chulho; Sohn, Jong Hee; Kim, Heung Cheol
2014-01-01
Necrotizing fasciitis is a soft tissue infection that is characterized by extensive necrosis of the subcutaneous fat, neurovascular structures, and fascia. Cerebral infarction after facial necrotizing fasciitis has been rarely reported. A 61-year-old woman with diabetes was admitted with painful swelling of her right cheek. One day later, she was stuporous and quadriplegic. A computed tomographic scan of her face revealed right facial infection in the periorbital soft tissue, parotid, buccal muscle, and maxillary sinusitis. A computed tomographic scan of the brain revealed cerebral infarction in the right hemisphere, left frontal area, and both cerebellum. Four days later, she died from cerebral edema and septic shock. Involvement of the cerebral vasculature, such as the carotid or vertebral artery by necrotizing fasciitis, can cause cerebral infarction. Facial necrotizing fasciitis should be treated early with surgical treatment and the appropriate antibiotic therapy. Copyright © 2014 National Stroke Association. Published by Elsevier Inc. All rights reserved.
Hecht, Harvey S; Bhatti, Tandeep
2009-01-01
Coronary computed tomographic angiography (CCTA) is not indicated in the setting of acute myocardial infarction in the emergency department (ED). Nonetheless, acute coronary syndromes may have atypical presentations, and CCTA may be inadvertently performed in this setting. This study was designed to determine the frequency and characteristics of CCTA imaging of unsuspected acute myocardial infarction in the ED. All CCTAs performed in the ED at Lenox Hill Hospital were reviewed for clinical indications and subsequent course; patients with documented acute myocardial infarction were identified. Of the 500 CCTAs performed on ED patients in the Lenox Hill laboratory, 5 patients (1%) were imaged during the initial phase of an unsuspected acute myocardial infarction; in all cases the CCTAs were key to the diagnosis. The imaging characteristics were (1) total or subtotal occlusion and (2) transmural hypodensity in the infarct area. Although acute myocardial infarction on CCTA in ED patients is an infrequent event, proper and prompt recognition is critical for appropriate patient care, particularly as applications to the ED increase.
IDIOS: An innovative index for evaluating dental imaging-based osteoporosis screening indices.
Barngkgei, Imad; Halboub, Esam; Almashraqi, Abeer Abdulkareem; Khattab, Razan; Al Haffar, Iyad
2016-09-01
The goal of this study was to develop a new index as an objective reference for evaluating current and newly developed indices used for osteoporosis screening based on dental images. Its name; IDIOS, stands for Index of Dental-imaging Indices of Osteoporosis Screening. A comprehensive PubMed search was conducted to retrieve studies on dental imaging-based indices for osteoporosis screening. The results of the eligible studies, along with other relevant criteria, were used to develop IDIOS, which has scores ranging from 0 (0%) to 15 (100%). The indices presented in the studies we included were then evaluated using IDIOS. The 104 studies that were included utilized 24, 4, and 9 indices derived from panoramic, periapical, and computed tomographic/cone-beam computed tomographic techniques, respectively. The IDIOS scores for these indices ranged from 0 (0%) to 11.75 (78.32%). IDIOS is a valuable reference index that facilitates the evaluation of other dental imaging-based osteoporosis screening indices. Furthermore, IDIOS can be utilized to evaluate the accuracy of newly developed indices.
System Performance Simulations of the RatCAP Awake Rat Brain Scanner
NASA Astrophysics Data System (ADS)
Shokouhi, S.; Vaska, P.; Schlyer, D. J.; Stoll, S. P.; Villanueva, A.; Kriplani, A.; Woody, C. L.
2005-10-01
The capability to create high quality images from data acquired by the Rat Conscious Animal PET tomograph (RatCAP) has been evaluated using modified versions of the PET Monte Carlo code Simulation System for Emission Tomography (SimSET). The proposed tomograph consists of lutetium oxyorthosilicate (LSO) crystals arranged in 12 4 /spl times/ 8 blocks. The effects of the RatCAPs small ring diameter (/spl sim/40 mm) and its block detector geometry on image quality for small animal studies have been investigated. Since the field of view will be almost as large as the ring diameter, radial elongation artifacts due to parallax error are expected to degrade the spatial resolution and thus the image quality at the edge of the field of view. In addition to Monte Carlo simulations, some preliminary results of experimentally acquired images in both two-dimensional (2-D) and 3-D modes are presented.
NASA Astrophysics Data System (ADS)
Munoz Burgos, J. M.; Brooks, N. H.; Fenstermacher, M. E.; Meyer, W. H.; Unterberg, E. A.; Schmitz, O.; Loch, S. D.; Balance, C. P.
2011-10-01
We apply new atomic modeling techniques to helium and deuterium for diagnostics in the divertor and scrape-off layer regions. Analysis of tomographically inverted images is useful for validating detachment prediction models and power balances in the divertor. We apply tomographic image inversion from fast tangential cameras of helium and Dα emission at the divertor in order to obtain 2D profiles of Te, Ne, and ND (neutral ion density profiles). The accuracy of the atomic models for He I will be cross-checked against Thomson scattering measurements of Te and Ne. This work summarizes several current developments and applications of atomic modeling into diagnostic at the DIII-D tokamak. Supported in part by the US DOE under DE-AC05-06OR23100, DE-FC02-04ER54698, DE-AC52-07NA27344, and DE-AC05-00OR22725.
NASA Technical Reports Server (NTRS)
Ter-Pogossian, M. M.; Hoffman, E. J.; Weiss, E. S.; Coleman, R. E.; Phelps, M. E.; Welch, M. J.; Sobel, B. E.
1975-01-01
A positron emission transverse tomograph device was developed which provides transaxial sectional images of the distribution of positron-emitting radionuclides in the heart. The images provide a quantitative three-dimensional map of the distribution of activity unencumbered by the superimposition of activity originating from regions overlying and underlying the plane of interest. PETT is used primarily with the cyclotron-produced radionuclides oxygen-15, nitrogen-13 and carbon-11. Because of the participation of these atoms in metabolism, they can be used to label metabolic substrates and intermediary molecules incorporated in myocardial metabolism.
Ionospheric-thermospheric UV tomography: 2. Comparison with incoherent scatter radar measurements
NASA Astrophysics Data System (ADS)
Dymond, K. F.; Nicholas, A. C.; Budzien, S. A.; Stephan, A. W.; Coker, C.; Hei, M. A.; Groves, K. M.
2017-03-01
The Special Sensor Ultraviolet Limb Imager (SSULI) instruments are ultraviolet limb scanning sensors that fly on the Defense Meteorological Satellite Program F16-F19 satellites. The SSULIs cover the 80-170 nm wavelength range which contains emissions at 91 and 136 nm, which are produced by radiative recombination of the ionosphere. We invert the 91.1 nm emission tomographically using a newly developed algorithm that includes optical depth effects due to pure absorption and resonant scattering. We present the details of our approach including how the optimal altitude and along-track sampling were determined and the newly developed approach we are using for regularizing the SSULI tomographic inversions. Finally, we conclude with validations of the SSULI inversions against Advanced Research Project Agency Long-range Tracking and Identification Radar (ALTAIR) incoherent scatter radar measurements and demonstrate excellent agreement between the measurements. As part of this study, we include the effects of pure absorption by O2, N2, and O in the inversions and find that best agreement between the ALTAIR and SSULI measurements is obtained when only O2 and O are included, but the agreement degrades when N2 absorption is included. This suggests that the absorption cross section of N2 needs to be reinvestigated near 91.1 nm wavelengths.
Wu, Abraham J; Bosch, Walter R; Chang, Daniel T; Hong, Theodore S; Jabbour, Salma K; Kleinberg, Lawrence R; Mamon, Harvey J; Thomas, Charles R; Goodman, Karyn A
2015-07-15
Current guidelines for esophageal cancer contouring are derived from traditional 2-dimensional fields based on bony landmarks, and they do not provide sufficient anatomic detail to ensure consistent contouring for more conformal radiation therapy techniques such as intensity modulated radiation therapy (IMRT). Therefore, we convened an expert panel with the specific aim to derive contouring guidelines and generate an atlas for the clinical target volume (CTV) in esophageal or gastroesophageal junction (GEJ) cancer. Eight expert academically based gastrointestinal radiation oncologists participated. Three sample cases were chosen: a GEJ cancer, a distal esophageal cancer, and a mid-upper esophageal cancer. Uniform computed tomographic (CT) simulation datasets and accompanying diagnostic positron emission tomographic/CT images were distributed to each expert, and the expert was instructed to generate gross tumor volume (GTV) and CTV contours for each case. All contours were aggregated and subjected to quantitative analysis to assess the degree of concordance between experts and to generate draft consensus contours. The panel then refined these contours to generate the contouring atlas. The κ statistics indicated substantial agreement between panelists for each of the 3 test cases. A consensus CTV atlas was generated for the 3 test cases, each representing common anatomic presentations of esophageal cancer. The panel agreed on guidelines and principles to facilitate the generalizability of the atlas to individual cases. This expert panel successfully reached agreement on contouring guidelines for esophageal and GEJ IMRT and generated a reference CTV atlas. This atlas will serve as a reference for IMRT contours for clinical practice and prospective trial design. Subsequent patterns of failure analyses of clinical datasets using these guidelines may require modification in the future. Copyright © 2015 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wu, Abraham J., E-mail: wua@mskcc.org; Bosch, Walter R.; Chang, Daniel T.
Purpose/Objective(s): Current guidelines for esophageal cancer contouring are derived from traditional 2-dimensional fields based on bony landmarks, and they do not provide sufficient anatomic detail to ensure consistent contouring for more conformal radiation therapy techniques such as intensity modulated radiation therapy (IMRT). Therefore, we convened an expert panel with the specific aim to derive contouring guidelines and generate an atlas for the clinical target volume (CTV) in esophageal or gastroesophageal junction (GEJ) cancer. Methods and Materials: Eight expert academically based gastrointestinal radiation oncologists participated. Three sample cases were chosen: a GEJ cancer, a distal esophageal cancer, and a mid-upper esophagealmore » cancer. Uniform computed tomographic (CT) simulation datasets and accompanying diagnostic positron emission tomographic/CT images were distributed to each expert, and the expert was instructed to generate gross tumor volume (GTV) and CTV contours for each case. All contours were aggregated and subjected to quantitative analysis to assess the degree of concordance between experts and to generate draft consensus contours. The panel then refined these contours to generate the contouring atlas. Results: The κ statistics indicated substantial agreement between panelists for each of the 3 test cases. A consensus CTV atlas was generated for the 3 test cases, each representing common anatomic presentations of esophageal cancer. The panel agreed on guidelines and principles to facilitate the generalizability of the atlas to individual cases. Conclusions: This expert panel successfully reached agreement on contouring guidelines for esophageal and GEJ IMRT and generated a reference CTV atlas. This atlas will serve as a reference for IMRT contours for clinical practice and prospective trial design. Subsequent patterns of failure analyses of clinical datasets using these guidelines may require modification in the future.« less
Wang, Shijun; McKenna, Matthew T; Nguyen, Tan B; Burns, Joseph E; Petrick, Nicholas; Sahiner, Berkman; Summers, Ronald M
2012-05-01
In this paper, we present development and testing results for a novel colonic polyp classification method for use as part of a computed tomographic colonography (CTC) computer-aided detection (CAD) system. Inspired by the interpretative methodology of radiologists using 3-D fly-through mode in CTC reading, we have developed an algorithm which utilizes sequences of images (referred to here as videos) for classification of CAD marks. For each CAD mark, we created a video composed of a series of intraluminal, volume-rendered images visualizing the detection from multiple viewpoints. We then framed the video classification question as a multiple-instance learning (MIL) problem. Since a positive (negative) bag may contain negative (positive) instances, which in our case depends on the viewing angles and camera distance to the target, we developed a novel MIL paradigm to accommodate this class of problems. We solved the new MIL problem by maximizing a L2-norm soft margin using semidefinite programming, which can optimize relevant parameters automatically. We tested our method by analyzing a CTC data set obtained from 50 patients from three medical centers. Our proposed method showed significantly better performance compared with several traditional MIL methods.
Launch of the I13-2 data beamline at the Diamond Light Source synchrotron
NASA Astrophysics Data System (ADS)
Bodey, A. J.; Rau, C.
2017-06-01
Users of the Diamond-Manchester Imaging Branchline I13-2 commonly spend many months analysing the large volumes of tomographic data generated in a single beamtime. This is due to the difficulties inherent in performing complicated, computationally-expensive analyses on large datasets with workstations of limited computing power. To improve productivity, a ‘data beamline’ was launched in January 2016. Users are scheduled for visits to the data beamline in the same way as for regular beamlines, with bookings made via the User Administration System and provision of financial support for travel and subsistence. Two high-performance graphics workstations were acquired, with sufficient RAM to enable simultaneous analysis of several tomographic volumes. Users are given high priority on Diamond’s central computing cluster for the duration of their visit, and if necessary, archived data are restored to a high-performance disk array. Within the first six months of operation, thirteen user visits were made, lasting an average of 4.5 days each. The I13-2 data beamline was the first to be launched at Diamond Light Source and, to the authors’ knowledge, the first to be formalised in this way at any synchrotron.
Wang, Shijun; McKenna, Matthew T.; Nguyen, Tan B.; Burns, Joseph E.; Petrick, Nicholas; Sahiner, Berkman
2012-01-01
In this paper we present development and testing results for a novel colonic polyp classification method for use as part of a computed tomographic colonography (CTC) computer-aided detection (CAD) system. Inspired by the interpretative methodology of radiologists using 3D fly-through mode in CTC reading, we have developed an algorithm which utilizes sequences of images (referred to here as videos) for classification of CAD marks. For each CAD mark, we created a video composed of a series of intraluminal, volume-rendered images visualizing the detection from multiple viewpoints. We then framed the video classification question as a multiple-instance learning (MIL) problem. Since a positive (negative) bag may contain negative (positive) instances, which in our case depends on the viewing angles and camera distance to the target, we developed a novel MIL paradigm to accommodate this class of problems. We solved the new MIL problem by maximizing a L2-norm soft margin using semidefinite programming, which can optimize relevant parameters automatically. We tested our method by analyzing a CTC data set obtained from 50 patients from three medical centers. Our proposed method showed significantly better performance compared with several traditional MIL methods. PMID:22552333
Shin, Kang-Jae; Gil, Young-Chun; Lee, Shin-Hyo; Kim, Jeong-Nam; Yoo, Ja-Young; Kim, Soon-Heum; Choi, Hyun-Gon; Shin, Hyun Jin; Koh, Ki-Seok; Song, Wu-Chul
2017-01-01
The aim of the present study was to assess normal eyeball protrusion from the orbital rim using two- and three-dimensional images and demonstrate the better suitability of CT images for assessment of exophthalmos. The facial computed tomographic (CT) images of Korean adults were acquired in sagittal and transverse views. The CT images were used in reconstructing three-dimensional volume of faces using computer software. The protrusion distances from orbital rims and the diameters of eyeballs were measured in the two views of the CT image and three-dimensional volume of the face. Relative exophthalmometry was calculated by the difference in protrusion distance between the right and left sides. The eyeball protrusion was 4.9 and 12.5 mm in sagittal and transverse views, respectively. The protrusion distances were 2.9 mm in the three-dimensional volume of face. There were no significant differences between right and left sides in the degree of protrusion, and the difference was within 2 mm in more than 90% of the subjects. The results of the present study will provide reliable criteria for precise diagnosis and postoperative monitoring using CT imaging of diseases such as thyroid-associated ophthalmopathy and orbital tumors.
Temporal sparsity exploiting nonlocal regularization for 4D computed tomography reconstruction
Kazantsev, Daniil; Guo, Enyu; Kaestner, Anders; Lionheart, William R. B.; Bent, Julian; Withers, Philip J.; Lee, Peter D.
2016-01-01
X-ray imaging applications in medical and material sciences are frequently limited by the number of tomographic projections collected. The inversion of the limited projection data is an ill-posed problem and needs regularization. Traditional spatial regularization is not well adapted to the dynamic nature of time-lapse tomography since it discards the redundancy of the temporal information. In this paper, we propose a novel iterative reconstruction algorithm with a nonlocal regularization term to account for time-evolving datasets. The aim of the proposed nonlocal penalty is to collect the maximum relevant information in the spatial and temporal domains. With the proposed sparsity seeking approach in the temporal space, the computational complexity of the classical nonlocal regularizer is substantially reduced (at least by one order of magnitude). The presented reconstruction method can be directly applied to various big data 4D (x, y, z+time) tomographic experiments in many fields. We apply the proposed technique to modelled data and to real dynamic X-ray microtomography (XMT) data of high resolution. Compared to the classical spatio-temporal nonlocal regularization approach, the proposed method delivers reconstructed images of improved resolution and higher contrast while remaining significantly less computationally demanding. PMID:27002902
Pathan, Faraz; Hecht, Harvey; Narula, Jagat; Marwick, Thomas H
2018-04-01
Evaluation of the left atrium and left atrial appendage for the presence of thrombus prior to cardioversion and pulmonary vein isolation, and of the entire heart for embolic sources in the setting of cryptogenic stroke, has long been standard medical care. Guidelines have uniformly recommended transesophageal echocardiography (TEE) to accomplish these goals. In recent years, computed tomographic angiography has demonstrated diagnostic accuracy similar to that of TEE for the detection of thrombus. Analysis of the pertinent data and relative merits of the 2 technologies leads to the conclusions that: 1) both modalities have some unique, nonoverlapping capabilities that may dictate their use in specific situations; 2) computed tomographic angiography is a reasonable alternative to TEE when the primary aim is to exclude left atrial and left atrial appendage thrombus and in patients in whom the risks associated with TEE outweigh the benefits; and 3) both options should be discussed with the patient in the setting of shared decision making. Copyright © 2018 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Paine, Nicola J; Bacon, Simon L; Pelletier, Roxanne; Arsenault, André; Diodati, Jean G; Lavoie, Kim L
2016-02-01
Women diagnosed with coronary artery disease (CAD) typically experience worse outcomes relative to men, possibly through diagnosis and treatment delays. Reasons for these delays may be influenced by mood and anxiety disorders, which are more prevalent in women and have symptoms (eg, palpitations and fatigue) that may be confounded with CAD. Our study examined sex differences in the association between mood and anxiety disorders and myocardial ischemia in patients with and without a CAD history presenting for exercise stress tests. A total of 2342 patients (women n=760) completed a single photon emission computed tomographic exercise stress test (standard Bruce Protocol) and underwent a psychiatric interview (The Primary Care Evaluation of Mental Disorders) to assess mood and anxiety disorders. Ischemia was assessed using single photon emission computed tomography, with odds ratio used to calculate the effect of sex and mood/anxiety on the presence of ischemia during stress testing by CAD history in a stratified analyses, adjusted for relevant covariates. There was a sex by anxiety interaction with ischemia in those without a CAD history (P=0.015): women with anxiety were more likely to exhibit ischemia during exercise than women without anxiety (odds ratio, 1.75; 95% confidence interval, 1.05-2.89). No significant effects were observed for men nor mood. Women with anxiety and no CAD history had higher rates of ischemia than women without anxiety. Results suggest that anxiety symptoms, many of which overlap with those of CAD, might mask CAD symptoms among women (but not men) and contribute to referral and diagnostic delays. Further research is needed to confirm this hypothesis. © 2016 American Heart Association, Inc.
Limited-angle tomography for analyzer-based phase-contrast X-ray imaging
Majidi, Keivan; Wernick, Miles N; Li, Jun; Muehleman, Carol; Brankov, Jovan G
2014-01-01
Multiple-Image Radiography (MIR) is an analyzer-based phase-contrast X-ray imaging method (ABI), which is emerging as a potential alternative to conventional radiography. MIR simultaneously generates three planar parametric images containing information about scattering, refraction and attenuation properties of the object. The MIR planar images are linear tomographic projections of the corresponding object properties, which allows reconstruction of volumetric images using computed tomography (CT) methods. However, when acquiring a full range of linear projections around the tissue of interest is not feasible or the scanning time is limited, limited-angle tomography techniques can be used to reconstruct these volumetric images near the central plane, which is the plane that contains the pivot point of the tomographic movement. In this work, we use computer simulations to explore the applicability of limited-angle tomography to MIR. We also investigate the accuracy of reconstructions as a function of number of tomographic angles for a fixed total radiation exposure. We use this function to find an optimal range of angles over which data should be acquired for limited-angle tomography MIR (LAT-MIR). Next, we apply the LAT-MIR technique to experimentally acquired MIR projections obtained in a cadaveric human thumb study. We compare the reconstructed slices near the central plane to the same slices reconstructed by CT-MIR using the full angular view around the object. Finally, we perform a task-based evaluation of LAT-MIR performance for different numbers of angular views, and use template matching to detect cartilage in the refraction image near the central plane. We use the signal-to-noise ratio of this test as the detectability metric to investigate an optimum range of tomographic angles for detecting soft tissues in LAT-MIR. Both results show that there is an optimum range of angular view for data acquisition where LAT-MIR yields the best performance, comparable to CT-MIR only if one considers volumetric images near the central plane and not the whole volume. PMID:24898008
Limited-angle tomography for analyzer-based phase-contrast x-ray imaging
NASA Astrophysics Data System (ADS)
Majidi, Keivan; Wernick, Miles N.; Li, Jun; Muehleman, Carol; Brankov, Jovan G.
2014-07-01
Multiple-image radiography (MIR) is an analyzer-based phase-contrast x-ray imaging method, which is emerging as a potential alternative to conventional radiography. MIR simultaneously generates three planar parametric images containing information about scattering, refraction and attenuation properties of the object. The MIR planar images are linear tomographic projections of the corresponding object properties, which allows reconstruction of volumetric images using computed tomography (CT) methods. However, when acquiring a full range of linear projections around the tissue of interest is not feasible or the scanning time is limited, limited-angle tomography techniques can be used to reconstruct these volumetric images near the central plane, which is the plane that contains the pivot point of the tomographic movement. In this work, we use computer simulations to explore the applicability of limited-angle tomography to MIR. We also investigate the accuracy of reconstructions as a function of number of tomographic angles for a fixed total radiation exposure. We use this function to find an optimal range of angles over which data should be acquired for limited-angle tomography MIR (LAT-MIR). Next, we apply the LAT-MIR technique to experimentally acquired MIR projections obtained in a cadaveric human thumb study. We compare the reconstructed slices near the central plane to the same slices reconstructed by CT-MIR using the full angular view around the object. Finally, we perform a task-based evaluation of LAT-MIR performance for different numbers of angular views, and use template matching to detect cartilage in the refraction image near the central plane. We use the signal-to-noise ratio of this test as the detectability metric to investigate an optimum range of tomographic angles for detecting soft tissues in LAT-MIR. Both results show that there is an optimum range of angular view for data acquisition where LAT-MIR yields the best performance, comparable to CT-MIR only if one considers volumetric images near the central plane and not the whole volume.
NASA Astrophysics Data System (ADS)
Newman, Kori; Nedimović, Mladen; Delescluse, Matthias; Menke, William; Canales, J. Pablo; Carbotte, Suzanne; Carton, Helene; Mutter, John
2010-05-01
We present traveltime tomographic models along closely spaced (~250 m), strike-parallel profiles that flank the axis of the East Pacific Rise at 9°41' - 9°57' N. The data were collected during a 3D (multi-streamer) multichannel seismic (MCS) survey of the ridge. Four 6-km long hydrophone streamers were towed by the ship along three along-axis sail lines, yielding twelve possible profiles over which to compute tomographic models. Based on the relative location between source-receiver midpoints and targeted subsurface structures, we have chosen to compute models for four of those lines. MCS data provide for a high density of seismic ray paths with which to constrain the model. Potentially, travel times for ~250,000 source-receiver pairs can be picked over the 30 km length of each model. However, such data density does not enhance the model resolution, so, for computational efficiency, the data are decimated so that ~15,000 picks per profile are used. Downward continuation of the shot gathers simulates an experimental geometry in which the sources and receivers are positioned just above the sea floor. This allows the shallowest sampling refracted arrivals to be picked and incorporated into the inversion whereas they would otherwise not be usable with traditional first-arrival travel-time tomographic techniques. Some of the far-offset deep-penetrating 2B refractions cannot be picked on the downward continued gathers due to signal processing artifacts. For this reason, we run a joint inversion by also including 2B traveltime picks from standard shot gathers. Uppermost velocity structure (seismic layer 2A thickness and velocity) is primarily constrained from 1D inversion of the nearest offset (<500 m) source-receiver travel-time picks for each downward continued shot gather. Deeper velocities are then computed in a joint 2D inversion that uses all picks from standard and downward continued shot gathers and incorporates the 1D results into the starting model. The resulting velocity models extend ~1 km into the crust. Preliminary results show thicker layer 2A and faster layer 2A velocities at fourth order ridge segment boundaries. Additionally, layer 2A thickens north of 9° 52' N, which is consistent with earlier investigations of this ridge segment. Slower layer 2B velocities are resolved in the vicinity of documented hydrothermal vent fields. We anticipate that additional analyses of the results will yield further insight into fine scale variations in near-axis mid-ocean ridge structure.
Computed tomography in cases of coccidioidal meningitis, with clinical correlation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shetter, A.G.; Fischer, D.W.; Flom, R.A.
1985-06-01
Cranial computed tomographic (CT) scans of 22 patients with coccidioidal meningitis were reviewed and their clinical course was analyzed. Abnormalities of the ventricular system or the basilar cisterns or both were present in 16 instances. Although it is not a definitive diagnostic tool, the CT scan is helpful in suggesting a diagnosis of coccidioidal meningitis and in predicting the prognosis of patients affected by the disease. 19 references, 4 figures, 2 tables.
Microfocus computed tomography in medicine
NASA Astrophysics Data System (ADS)
Obodovskiy, A. V.
2018-02-01
Recent advances in the field of high-frequency power schemes for X-ray devices allow the creation of high-resolution instruments. At the department of electronic devices and Equipment of the St. Petersburg State Electrotechnical University, a model of a microfocus computer tomograph was developed. Used equipment allows to receive projection data with an increase up to 100 times. A distinctive feature of the device is the possibility of implementing various schemes for obtaining projection data.
Acoustic emission characterization of microcracking in laboratory-scale hydraulic fracturing tests
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hampton, Jesse; Gutierrez, Marte; Matzar, Luis
Understanding microcracking near coalesced fracture generation is critically important for hydrocarbon and geothermal reservoir characterization as well as damage evaluation in civil engineering structures. Dense and sometimes random microcracking near coalesced fracture formation alters the mechanical properties of the nearby virgin material. Individual microcrack characterization is also significant in quantifying the material changes near the fracture faces (i.e. damage). Acoustic emission (AE) monitoring and analysis provide unique information regarding the microcracking process temporally, and information concerning the source characterization of individual microcracks can be extracted. In this context, laboratory hydraulic fracture tests were carried out while monitoring the AEs frommore » several piezoelectric transducers. In-depth post-processing of the AE event data was performed for the purpose of understanding the individual source mechanisms. Several source characterization techniques including moment tensor inversion, event parametric analysis, and volumetric deformation analysis were adopted. Post-test fracture characterization through coring, slicing and micro-computed tomographic imaging was performed to determine the coalesced fracture location and structure. Distinct differences in fracture characteristics were found spatially in relation to the openhole injection interval. Individual microcrack AE analysis showed substantial energy reduction emanating spatially from the injection interval. Lastly, it was quantitatively observed that the recorded AE signals provided sufficient information to generalize the damage radiating spatially away from the injection wellbore.« less
Acoustic emission characterization of microcracking in laboratory-scale hydraulic fracturing tests
Hampton, Jesse; Gutierrez, Marte; Matzar, Luis; ...
2018-06-11
Understanding microcracking near coalesced fracture generation is critically important for hydrocarbon and geothermal reservoir characterization as well as damage evaluation in civil engineering structures. Dense and sometimes random microcracking near coalesced fracture formation alters the mechanical properties of the nearby virgin material. Individual microcrack characterization is also significant in quantifying the material changes near the fracture faces (i.e. damage). Acoustic emission (AE) monitoring and analysis provide unique information regarding the microcracking process temporally, and information concerning the source characterization of individual microcracks can be extracted. In this context, laboratory hydraulic fracture tests were carried out while monitoring the AEs frommore » several piezoelectric transducers. In-depth post-processing of the AE event data was performed for the purpose of understanding the individual source mechanisms. Several source characterization techniques including moment tensor inversion, event parametric analysis, and volumetric deformation analysis were adopted. Post-test fracture characterization through coring, slicing and micro-computed tomographic imaging was performed to determine the coalesced fracture location and structure. Distinct differences in fracture characteristics were found spatially in relation to the openhole injection interval. Individual microcrack AE analysis showed substantial energy reduction emanating spatially from the injection interval. Lastly, it was quantitatively observed that the recorded AE signals provided sufficient information to generalize the damage radiating spatially away from the injection wellbore.« less
GATE - Geant4 Application for Tomographic Emission: a simulation toolkit for PET and SPECT
Jan, S.; Santin, G.; Strul, D.; Staelens, S.; Assié, K.; Autret, D.; Avner, S.; Barbier, R.; Bardiès, M.; Bloomfield, P. M.; Brasse, D.; Breton, V.; Bruyndonckx, P.; Buvat, I.; Chatziioannou, A. F.; Choi, Y.; Chung, Y. H.; Comtat, C.; Donnarieix, D.; Ferrer, L.; Glick, S. J.; Groiselle, C. J.; Guez, D.; Honore, P.-F.; Kerhoas-Cavata, S.; Kirov, A. S.; Kohli, V.; Koole, M.; Krieguer, M.; van der Laan, D. J.; Lamare, F.; Largeron, G.; Lartizien, C.; Lazaro, D.; Maas, M. C.; Maigne, L.; Mayet, F.; Melot, F.; Merheb, C.; Pennacchio, E.; Perez, J.; Pietrzyk, U.; Rannou, F. R.; Rey, M.; Schaart, D. R.; Schmidtlein, C. R.; Simon, L.; Song, T. Y.; Vieira, J.-M.; Visvikis, D.; Van de Walle, R.; Wieërs, E.; Morel, C.
2012-01-01
Monte Carlo simulation is an essential tool in emission tomography that can assist in the design of new medical imaging devices, the optimization of acquisition protocols, and the development or assessment of image reconstruction algorithms and correction techniques. GATE, the Geant4 Application for Tomographic Emission, encapsulates the Geant4 libraries to achieve a modular, versatile, scripted simulation toolkit adapted to the field of nuclear medicine. In particular, GATE allows the description of time-dependent phenomena such as source or detector movement, and source decay kinetics. This feature makes it possible to simulate time curves under realistic acquisition conditions and to test dynamic reconstruction algorithms. This paper gives a detailed description of the design and development of GATE by the OpenGATE collaboration, whose continuing objective is to improve, document, and validate GATE by simulating commercially available imaging systems for PET and SPECT. Large effort is also invested in the ability and the flexibility to model novel detection systems or systems still under design. A public release of GATE licensed under the GNU Lesser General Public License can be downloaded at the address http://www-lphe.ep.ch/GATE/. Two benchmarks developed for PET and SPECT to test the installation of GATE and to serve as a tutorial for the users are presented. Extensive validation of the GATE simulation platform has been started, comparing simulations and measurements on commercially available acquisition systems. References to those results are listed. The future prospects toward the gridification of GATE and its extension to other domains such as dosimetry are also discussed. PMID:15552416
Towards Omni-Tomography—Grand Fusion of Multiple Modalities for Simultaneous Interior Tomography
Wang, Ge; Zhang, Jie; Gao, Hao; Weir, Victor; Yu, Hengyong; Cong, Wenxiang; Xu, Xiaochen; Shen, Haiou; Bennett, James; Furth, Mark; Wang, Yue; Vannier, Michael
2012-01-01
We recently elevated interior tomography from its origin in computed tomography (CT) to a general tomographic principle, and proved its validity for other tomographic modalities including SPECT, MRI, and others. Here we propose “omni-tomography”, a novel concept for the grand fusion of multiple tomographic modalities for simultaneous data acquisition in a region of interest (ROI). Omni-tomography can be instrumental when physiological processes under investigation are multi-dimensional, multi-scale, multi-temporal and multi-parametric. Both preclinical and clinical studies now depend on in vivo tomography, often requiring separate evaluations by different imaging modalities. Over the past decade, two approaches have been used for multimodality fusion: Software based image registration and hybrid scanners such as PET-CT, PET-MRI, and SPECT-CT among others. While there are intrinsic limitations with both approaches, the main obstacle to the seamless fusion of multiple imaging modalities has been the bulkiness of each individual imager and the conflict of their physical (especially spatial) requirements. To address this challenge, omni-tomography is now unveiled as an emerging direction for biomedical imaging and systems biomedicine. PMID:22768108
Drive-by large-region acoustic noise-source mapping via sparse beamforming tomography.
Tuna, Cagdas; Zhao, Shengkui; Nguyen, Thi Ngoc Tho; Jones, Douglas L
2016-10-01
Environmental noise is a risk factor for human physical and mental health, demanding an efficient large-scale noise-monitoring scheme. The current technology, however, involves extensive sound pressure level (SPL) measurements at a dense grid of locations, making it impractical on a city-wide scale. This paper presents an alternative approach using a microphone array mounted on a moving vehicle to generate two-dimensional acoustic tomographic maps that yield the locations and SPLs of the noise-sources sparsely distributed in the neighborhood traveled by the vehicle. The far-field frequency-domain delay-and-sum beamforming output power values computed at multiple locations as the vehicle drives by are used as tomographic measurements. The proposed method is tested with acoustic data collected by driving an electric vehicle with a rooftop-mounted microphone array along a straight road next to a large open field, on which various pre-recorded noise-sources were produced by a loudspeaker at different locations. The accuracy of the tomographic imaging results demonstrates the promise of this approach for rapid, low-cost environmental noise-monitoring.
Pneumorachis caused by metastatic gas gangrene.
Thompson, George R; Crawford, George E
2009-01-01
Pneumorachis has previously been described only after spread from a contiguous site or after a traumatic event. Our patient experienced sepsis due to multiple enteric organisms, and gas was identified within the spinal canal on computed tomographic imaging. We present the 1st case of pneumorachis caused by disseminated infection.
Various origins of the duplicated middle cerebral artery.
Tutar, Nihal Uslu; Töre, Hüseyin Gürkan; Kirbaş, Ismail; Tarhan, Nefise Cağla; Coşkun, Mehmet
2008-10-01
We describe the features of a duplicated middle cerebral artery identified by computed tomographic angiography that originates from a previously undefined origin, ie, from the petrous portion of the internal carotid artery. Recognition of this anomaly is important in patients with a possible aneurysm, which was not present in our patient.
3D spectral imaging with synchrotron Fourier transform infrared spectro-microtomography
Michael C. Martin; Charlotte Dabat-Blondeau; Miriam Unger; Julia Sedlmair; Dilworth Y. Parkinson; Hans A. Bechtel; Barbara Illman; Jonathan M. Castro; Marco Keiluweit; David Buschke; Brenda Ogle; Michael J. Nasse; Carol J. Hirschmugl
2013-01-01
We report Fourier transform infrared spectro-microtomography, a nondestructive three-dimensional imaging approach that reveals the distribution of distinctive chemical compositions throughout an intact biological or materials sample. The method combines mid-infrared absorption contrast with computed tomographic data acquisition and reconstruction to enhance chemical...
Focal fibrocartilaginous dysplasia and tibia vara: a case report.
Cockshott, W P; Martin, R; Friedman, L; Yuen, M
1994-07-01
A 2-year-old black boy with focal fibrocartilaginous dysplasia is described with illustrations of the typical radiographic appearances supplemented by computed tomographic and magnetic resonance images. Since this rare condition is self-correcting, diagnosis is important so that surgical intervention and biopsy can be avoided and conservative management instituted.
Reversible suprasellar pituitary mass secondary to hypothyroidism
DOE Office of Scientific and Technical Information (OSTI.GOV)
Atchison, J.A.; Lee, P.A.; Albright, A.L.
1989-12-08
Sellar enlargement and suprasellar extension of a pituitary mass, demonstrated by magnetic resonance imaging or computed tomographic scanning in three children with primary hypothyroidism, resolved after treatment with levothyroxine sodium. This condition, a logical consequence of the pathogenesis of primary hypothyroidism, must be considered in patients with pituitary and suprasellar masses.
NASA Astrophysics Data System (ADS)
Pöhlitz, Julia; Rücknagel, Jan; Schlüter, Steffen; Vogel, Hans-Jörg
2017-04-01
In recent years there has been an increasing application of conservation tillage techniques where the soil is no longer turned, but only loosened or left completely untilled. Dead plant material remains on the soil surface, which provides environmental and economic benefits such as the conservation of water, preventing soil erosion and saving time during seedbed preparation. There is a variety of conservation tillage systems, e.g. mulch till, no-till and strip tillage, which is a special feature. In strip tillage, the seed bed is divided into a seed zone (strip-till within the seed row: STWS) and a soil management zone (strip-till between the seed row: STBS). However, each tillage application affects physical soil properties and processes. Here, the combined application of classical soil mechanical and computed tomographic methods is used on a Chernozem (texture 0-30 cm: silt loam) to show small-scale structural differences under strip tillage (STWS, STBS) compared to no-till (NT) and mulch till (MT). In addition to the classical soil physical parameters dry bulk density and saturated conductivity (years: 2012, 2014, 2015) at soil depths 2-8 and 12-18 cm, stress-strain tests were carried out to map mechanical behavior. The stress-strain tests were performed for a load range from 5-550 kPa at 12-18 cm depth (year 2015). Mechanical precompression stress was determined on the stress-dry bulk density curves. Further, CT image cross sections and computed tomographic examinations (average pore size, porosity, connectivity, and anisotropy) were used from the same soil samples. For STBS and NT, a significant increase in dry bulk density was observed over the course of time compared to STWS and MT, which was more pronounced at 2-8 cm than at 12-18 cm depth. Despite higher dry bulk density, STBS displayed higher saturated conductivity in contrast to STWS, which can be attributed to higher earthworm abundance. In strip tillage, structural differences were identified. Mechanical precompression stress was significantly higher for STBS (141 kPa) than STWS (38 kPa). In addition, the CT image cross sections and the computed tomographic parameters confirmed the mechanically more stable soil structure observed under STBS with a higher initial average pore size but lower porosity and connectivity values compared to STWS. The reason for this is the lack of tillage. On the other hand, tillage at STWS created a loosened, porous and connective substrate. For all variants, the increasing load application led to progressive homogenization processes of the soil structure. At the same time, as stress application increased in all variants, the increase in dry bulk density led to a decrease in average pore size, porosity, and connectivity, while anisotropy increased. It was possible to confirm that strip tillage combines the advantages of no-till and a deeper conservation primary tillage, since on the one hand MT and STWS and on the other hand STBS and NT showed very similar soil structures. The computed tomographic parameters therefore provide valuable information about the impact of tillage on microscopic pore space attributes that improve our understanding about soil functional behavior at much larger scales.
Advanced Ultrasonic Tomograph of Children's Bones
NASA Astrophysics Data System (ADS)
Lasaygues, Philippe; Lefebvre, Jean-Pierre; Guillermin, Régine; Kaftandjian, Valérie; Berteau, Jean-Philippe; Pithioux, Martine; Petit, Philippe
This study deals with the development of an experimental device for performing ultrasonic computed tomography (UCT) on bone in pediatric degrees. The children's bone tomographs obtained in this study, were based on the use of a multiplexed 2-D ring antenna (1 MHz and 3 MHz) designed for performing electronic and mechanical scanning. Although this approach is known to be a potentially valuable means of imaging objects with similar acoustical impedances, problems arise when quantitative images of more highly contrasted media such as bones are required. Various strategies and various mathematical procedures for modeling the wave propagation based on Born approximations have been developed at our laboratory, which are suitable for use with pediatric cases. Inversions of the experimental data obtained are presented.
Tomographic determination of the power distribution in electron beams
Teruya, Alan T.; Elmer, John W.
1996-01-01
A tomographic technique for determining the power distribution of an electron beam using electron beam profile data acquired from a modified Faraday cup to create an image of the current density in high and low power beams. A refractory metal disk with a number of radially extending slits is placed above a Faraday cup. The beam is swept in a circular pattern so that its path crosses each slit in a perpendicular manner, thus acquiring all the data needed for a reconstruction in one circular sweep. Also, a single computer is used to generate the signals actuating the sweep, to acquire that data, and to do the reconstruction, thus reducing the time and equipment necessary to complete the process.
Tomographic determination of the power distribution in electron beams
Teruya, A.T.; Elmer, J.W.
1996-12-10
A tomographic technique for determining the power distribution of an electron beam using electron beam profile data acquired from a modified Faraday cup to create an image of the current density in high and low power beams is disclosed. A refractory metal disk with a number of radially extending slits is placed above a Faraday cup. The beam is swept in a circular pattern so that its path crosses each slit in a perpendicular manner, thus acquiring all the data needed for a reconstruction in one circular sweep. Also, a single computer is used to generate the signals actuating the sweep, to acquire that data, and to do the reconstruction, thus reducing the time and equipment necessary to complete the process. 4 figs.
Computation in generalised probabilisitic theories
NASA Astrophysics Data System (ADS)
Lee, Ciarán M.; Barrett, Jonathan
2015-08-01
From the general difficulty of simulating quantum systems using classical systems, and in particular the existence of an efficient quantum algorithm for factoring, it is likely that quantum computation is intrinsically more powerful than classical computation. At present, the best upper bound known for the power of quantum computation is that {{BQP}}\\subseteq {{AWPP}}, where {{AWPP}} is a classical complexity class (known to be included in {{PP}}, hence {{PSPACE}}). This work investigates limits on computational power that are imposed by simple physical, or information theoretic, principles. To this end, we define a circuit-based model of computation in a class of operationally-defined theories more general than quantum theory, and ask: what is the minimal set of physical assumptions under which the above inclusions still hold? We show that given only an assumption of tomographic locality (roughly, that multipartite states and transformations can be characterized by local measurements), efficient computations are contained in {{AWPP}}. This inclusion still holds even without assuming a basic notion of causality (where the notion is, roughly, that probabilities for outcomes cannot depend on future measurement choices). Following Aaronson, we extend the computational model by allowing post-selection on measurement outcomes. Aaronson showed that the corresponding quantum complexity class, {{PostBQP}}, is equal to {{PP}}. Given only the assumption of tomographic locality, the inclusion in {{PP}} still holds for post-selected computation in general theories. Hence in a world with post-selection, quantum theory is optimal for computation in the space of all operational theories. We then consider whether one can obtain relativized complexity results for general theories. It is not obvious how to define a sensible notion of a computational oracle in the general framework that reduces to the standard notion in the quantum case. Nevertheless, it is possible to define computation relative to a ‘classical oracle’. Then, we show there exists a classical oracle relative to which efficient computation in any theory satisfying the causality assumption does not include {{NP}}.
Direct integration of the inverse Radon equation for X-ray computed tomography.
Libin, E E; Chakhlov, S V; Trinca, D
2016-11-22
A new mathematical appoach using the inverse Radon equation for restoration of images in problems of linear two-dimensional x-ray tomography is formulated. In this approach, Fourier transformation is not used, and it gives the chance to create the practical computing algorithms having more reliable mathematical substantiation. Results of software implementation show that for especially for low number of projections, the described approach performs better than standard X-ray tomographic reconstruction algorithms.
Extranodal manifestations of lymphoma on [18F]FDG-PET/CT: a pictorial essay
Kashyap, Raghava; Manohar, Kuruva; Harisankar, Chidambaram Natrajan Balasubramanian; Bhattacharya, Anish; Singh, Baljinder; Malhotra, Pankaj; Varma, Subhash
2011-01-01
Abstract Lymphoma is the seventh most common type of malignancy in both sexes. It is a neoplastic proliferation of lymphoid cells at various stages of differentiation and affects lymph nodes with infiltration into the bone marrow, spleen and thymus. However, extra nodal involvement is frequently seen in many cases. With the development of dedicated positron emission tomography (PET) scanners with fused computed tomographic (CT) systems in the same gantry, [18F]fluorodeoxyglucose (FDG)-PET/CT has become a major tool in the evaluation of lymphomas and it is inimitable in certain situations such as assessment of response to therapy. Extranodal lymphoma can present with diverse manifestations and sometimes mimics other organ-related pathologies. Knowledge of the protean manifestations of extranodal lymphoma is required to accurately detect the disease and differentiate it from the various physiologic and benign causes of FDG uptake in various organs. We present a case series of extranodal involvement of histologically proven cases of lymphomas detected on FDG-PET/CT at our institute to demonstrate the challenges in interpretation of extranodal lymphoma. PMID:22123338
Ultrafast X-ray Imaging of Fuel Sprays
NASA Astrophysics Data System (ADS)
Wang, Jin
2007-01-01
Detailed analysis of fuel sprays has been well recognized as an important step for optimizing the operation of internal combustion engines to improve efficiency and reduce emissions. Ultrafast radiographic and tomographic techniques have been developed for probing the fuel distribution close to the nozzles of direct-injection diesel and gasoline injectors. The measurement was made using x-ray absorption of monochromatic synchrotron-generated radiation, allowing quantitative determination of the fuel distribution in this optically impenetrable region with a time resolution on the order of 1 μs. Furthermore, an accurate 3-dimensional fuel-density distribution, in the form of fuel volume fraction, was obtained by the time-resolved computed tomography. These quantitative measurements constitute the most detailed near-nozzle study of a fuel spray to date. With high-energy and high-brilliance x-ray beams available at the Advanced Photon Source, propagation-based phase-enhanced imaging was developed as a unique metrology technique to visualize the interior of an injection nozzle through a 3-mm-thick steel with a 10-μs temporal resolution, which is virtually impossible by any other means.
A restraint-free small animal SPECT imaging system with motion tracking
DOE Office of Scientific and Technical Information (OSTI.GOV)
Weisenberger, A.G.; Gleason, S.S.; Goddard, J.
2005-06-01
We report on an approach toward the development of a high-resolution single photon emission computed tomography (SPECT) system to image the biodistribution of radiolabeled tracers such as Tc-99m and I-125 in unrestrained/unanesthetized mice. An infrared (IR)-based position tracking apparatus has been developed and integrated into a SPECT gantry. The tracking system is designed to measure the spatial position of a mouse's head at a rate of 10-15 frames per second with submillimeter accuracy. The high-resolution, gamma imaging detectors are based on pixellated NaI(Tl) crystal scintillator arrays, position-sensitive photomultiplier tubes, and novel readout circuitry requiring fewer analog-digital converter (ADC) channels whilemore » retaining high spatial resolution. Two SPECT gamma camera detector heads based upon position-sensitive photomultiplier tubes have been built and installed onto the gantry. The IR landmark-based pose measurement and tracking system is under development to provide animal position data during a SPECT scan. The animal position and orientation data acquired by the tracking system will be used for motion correction during the tomographic image reconstruction.« less
Park, Ko Woon; Kim, Seong Hyun; Choi, Seong Ho; Lee, Won Jae
2010-01-01
To evaluate useful computed tomographic features to differentiate nonneoplastic and neoplastic gallbladder polyps 1 cm or bigger. Thirty-one patients with 32 nonneoplastic polyps and 67 patients with 73 neoplastic polyps 1 cm or bigger underwent unenhanced and dual-phase (arterial and portal venous phases) multi-detector row computed tomography. Gallbladder polyps were diagnosed by cholecystectomy. Computed tomographic features including size (
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jacobsson-Svard, Staffan; Smith, Leon E.; White, Timothy
The potential for gamma emission tomography (GET) to detect partial defects within a spent nuclear fuel assembly has been assessed within the IAEA Support Program project JNT 1955, phase I, which was completed and reported to the IAEA in October 2016. Two safeguards verification objectives were identified in the project; (1) independent determination of the number of active pins that are present in a measured assembly, in the absence of a priori information about the assembly; and (2) quantitative assessment of pin-by-pin properties, for example the activity of key isotopes or pin attributes such as cooling time and relative burnup,more » under the assumption that basic fuel parameters (e.g., assembly type and nominal fuel composition) are known. The efficacy of GET to meet these two verification objectives was evaluated across a range of fuel types, burnups and cooling times, while targeting a total interrogation time of less than 60 minutes. The evaluations were founded on a modelling and analysis framework applied to existing and emerging GET instrument designs. Monte Carlo models of different fuel types were used to produce simulated tomographer responses to large populations of “virtual” fuel assemblies. The simulated instrument response data were then processed using a variety of tomographic-reconstruction and image-processing methods, and scoring metrics were defined and used to evaluate the performance of the methods.This paper describes the analysis framework and metrics used to predict tomographer performance. It also presents the design of a “universal” GET (UGET) instrument intended to support the full range of verification scenarios envisioned by the IAEA. Finally, it gives examples of the expected partial-defect detection capabilities for some fuels and diversion scenarios, and it provides a comparison of predicted performance for the notional UGET design and an optimized variant of an existing IAEA instrument.« less
NASA Astrophysics Data System (ADS)
Gu, Z.; Bao, Q.; Taschereau, R.; Wang, H.; Bai, B.; Chatziioannou, A. F.
2014-06-01
Small animal positron emission tomography (PET) systems are often designed by employing close geometry configurations. Due to the different characteristics caused by geometrical factors, these tomographs require data acquisition protocols that differ from those optimized for conventional large diameter ring systems. In this work we optimized the energy window for data acquisitions with PETbox4, a 50 mm detector separation (box-like geometry) pre-clinical PET scanner, using the Geant4 Application for Tomographic Emission (GATE). The fractions of different types of events were estimated using a voxelized phantom including a mouse as well as its supporting chamber, mimicking a realistic mouse imaging environment. Separate code was developed to extract additional information about the gamma interactions for more accurate event type classification. Three types of detector backscatter events were identified in addition to the trues, phantom scatters and randoms. The energy window was optimized based on the noise equivalent count rate (NECR) and scatter fraction (SF) with lower-level discriminators (LLD) corresponding to energies from 150 keV to 450 keV. The results were validated based on the calculated image uniformity, spillover ratio (SOR) and recovery coefficient (RC) from physical measurements using the National Electrical Manufacturers Association (NEMA) NU-4 image quality phantom. These results indicate that when PETbox4 is operated with a more narrow energy window (350-650 keV), detector backscatter rejection is unnecessary. For the NEMA NU-4 image quality phantom, the SOR for the water chamber decreases by about 45% from 15.1% to 8.3%, and the SOR for the air chamber decreases by 31% from 12.0% to 8.3% at the LLDs of 150 and 350 keV, without obvious change in uniformity, further supporting the simulation based optimization. The optimization described in this work is not limited to PETbox4, but also applicable or helpful to other small inner diameter geometry scanners.
Detection of isolated cerebrovascular beta-amyloid with Pittsburgh compound B.
Greenberg, Steven M; Grabowski, Thomas; Gurol, M Edip; Skehan, Maureen E; Nandigam, R N Kaveer; Becker, John A; Garcia-Alloza, Monica; Prada, Claudia; Frosch, Matthew P; Rosand, Jonathan; Viswanathan, Anand; Smith, Eric E; Johnson, Keith A
2008-11-01
Imaging of cerebrovascular beta-amyloid (cerebral amyloid angiopathy) is complicated by the nearly universal overlap of this pathology with Alzheimer's pathology. We performed positron emission tomographic imaging with Pittsburgh Compound B on 42-year-old man with early manifestations of Iowa-type hereditary cerebral amyloid angiopathy, a form of the disorder with little or no plaque deposits of fibrillar beta-amyloid. The results demonstrated increased Pittsburgh Compound B retention selectively in occipital cortex, sparing regions typically labeled in Alzheimer's disease. These results offer compelling evidence that Pittsburgh Compound B positron emission tomography can noninvasively detect isolated cerebral amyloid angiopathy before overt signs of tissue damage such as hemorrhage or white matter lesions.
CT Imaging of Hardwood Logs for Lumber Production
Daniel L. Schmoldt; Pei Li; A. Lynn Abbott
1996-01-01
Hardwood sawmill operators need to improve the conversion of raw material (logs) into lumber. Internal log scanning provides detailed information that can aid log processors in improving lumber recovery. However, scanner data (i.e. tomographic images) need to be analyzed prior to presentation to saw operators. Automatic labeling of computer tomography (CT) images is...
Diagnostic cardiology: Noninvasive imaging techniques
DOE Office of Scientific and Technical Information (OSTI.GOV)
Come, P.C.
1985-01-01
This book contains 23 chapters. Some of the chapter titles are: The chest x-ray and cardiac series; Computed tomographic scanning of the heart, coronary arteries, and great vessels; Digital subtraction angiography in the assessment of cardiovascular disease; Magnetic resonance: technique and cardiac applications; Basics of radiation physics and instrumentation; and Nuclear imaging: the assessment of cardiac performance.
USDA-ARS?s Scientific Manuscript database
There is growing use of hybrid catfish (Ictalurus punctatus ' X Ictalurus furcatus ') in commercial aquaculture to utilize hybrid vigour to improve production A conjoined twin specimen found during the course of production studies by the United States Department of Agriculture Catfish Genetic Resear...
Bridging the Gap between Basic and Clinical Sciences: A Description of a Radiological Anatomy Course
ERIC Educational Resources Information Center
Torres, Anna; Staskiewicz, Grzegorz J.; Lisiecka, Justyna; Pietrzyk, Lukasz; Czekajlo, Michael; Arancibia, Carlos U.; Maciejewski, Ryszard; Torres, Kamil
2016-01-01
A wide variety of medical imaging techniques pervade modern medicine, and the changing portability and performance of tools like ultrasound imaging have brought these medical imaging techniques into the everyday practice of many specialties outside of radiology. However, proper interpretation of ultrasonographic and computed tomographic images…
2013-08-01
variable. Tourniquet and tranexamic acid (TXA) use before CT imaging were also recorded. Admission temperature and systolic blood pressure (SBP) were...Trauma Data Bank. Ann Surg. 2004;240:490Y498. 11. Morrison JJ, Dubose JJ, Rasmussen TE, Midwinter MJ. Military appli- cation of tranexamic acid in
[A Case of Pancreatic Neuroendocrine Tumor with Necrolytic Migratory Erythema].
Hijikawa, Takeshi; Kitade, Hiroaki; Yanagida, Hidesuke; Yamada, Masanori; Yoshioka, Kazuhiko; Shijimaya, Takako; Kiyohara, Takahiro; Uemura, Yoshiko; Kon, Masanori
2017-10-01
A 45-year-old man was admitted because of necrolytic migratory erythema. A computed tomographic scan of the abdomen revealed a 4.5cm mass in the tail of the pancreas. We performed distal pancreatectomy and splenectomy, and a definitive diagnosis of pancreatic neuroendocrine tumor(WHO class grade 2)was made histopathologically.
Misdiagnosis of acute peripheral vestibulopathy in central nervous ischemic infarction.
Braun, Eva Maria; Tomazic, Peter Valentin; Ropposch, Thorsten; Nemetz, Ulrike; Lackner, Andreas; Walch, Christian
2011-12-01
Vertigo is a very common symptom at otorhinolaryngology (ENT), neurological, and emergency units, but often, it is difficult to distinguish between vertigo of peripheral and central origin. We conducted a retrospective analysis of a hospital database, including all patients admitted to the ENT University Hospital Graz after neurological examination, with a diagnosis of peripheral vestibular vertigo and subsequent diagnosis of central nervous infarction as the actual cause for the vertigo. Twelve patients were included in this study. All patients with acute spinning vertigo after a thorough neurological examination and with uneventful computed tomographic scans were referred to our ENT department. Nine of them presented with horizontal nystagmus. Only 1 woman experienced additional hearing loss. The mean diagnostic delay to the definite diagnosis of a central infarction through magnetic resonance imaging was 4 days (SD, 2.3 d). A careful otologic and neurological examination, including the head impulse test and caloric testing, is mandatory. Because ischemic events cannot be diagnosed in computed tomographic scans at an early stage, we strongly recommend to perform cranial magnetic resonance imaging within 48 hours from admission if vertigo has not improved under conservative treatment.
Long-term efficacy of biomodeled polymethyl methacrylate implants for orbitofacial defects.
Groth, Michael J; Bhatnagar, Aparna; Clearihue, William J; Goldberg, Robert A; Douglas, Raymond S
2006-01-01
To report the long-term efficacy of custom polymethyl methacrylate implants using high-resolution computed tomographic modeling in the reconstruction of complex orbitofacial defects secondary to trauma. Nine patients with complex orbitofacial bone defects after trauma were evaluated for this retrospective, nonrandomized, noncomparative study. All the patients underwent reconstruction using custom, heat-cured polymethyl methacrylate implants. Patients were followed up postoperatively and evaluated for complications. Nine consecutive patients (5 men and 4 women) aged 28 to 63 years who underwent surgical reconstruction using prefabricated, heat-cured polymethyl methacrylate implants were included in the study. The interval between injury and presentation ranged from 1 month to 40 years. There were no significant complications, including infection, extrusion, or displacement of the implant. In all of the patients, wound healing was uneventful, with antibiotic drugs administered perioperatively. Mean follow-up was 4.3 years from the first visit (range, 6 months to 10 years). Computed tomographic biomodeled, prefabricated, heat-cured polymethyl methacrylate implants are well tolerated in the long term. Their advantages include customized design, long-term biocompatibility, and excellent aesthetic results.
Johnson, Jeremy J; Garwe, Tabitha; Raines, Alexander R; Thurman, Joseph B; Carter, Sandra; Bender, Jeffrey S; Albrecht, Roxie M
2013-03-01
Diagnostic laparoscopy (DL) has decreased the rate of nontherapeutic laparotomy for patients suffering from penetrating injuries. We evaluated whether DL similarly lowers the rate of nontherapeutic laparotomy for patients with blunt injuries. All patients undergoing DL over a 10-year period (ie, 2001-2010) in a single level 1 trauma center were classified by the mechanism of injury. Demographic and perioperative data were compared using the Student t and Fisher exact tests. There were 131 patients included, 22 of whom sustained blunt injuries. Patients suffering from blunt injuries were more severely injured (Injury Severity Score 18.0 vs 7.3, P = .0001). The most common indication for DL after blunt injury was a computed tomographic scan concerning for bowel injury (59.1%). The rate of nontherapeutic laparotomy for patients sustaining penetrating vs blunt injury was 1.8% and nil, respectively. DL, when coupled with computed tomographic findings, is an effective tool for the initial management of patients with blunt injuries. Copyright © 2013 Elsevier Inc. All rights reserved.
Fisher, Brian M; Cowles, Steven; Matulich, Jennifer R; Evanson, Bradley G; Vega, Diana; Dissanaike, Sharmila
2013-12-01
Guidelines are in place directing the clearance of the cervical spine in patients who are awake, alert, and oriented, but a gold standard has not been recognized for patients who are obtunded. Our study is designed to determine if magnetic resonance imaging (MRI) detects clinically significant injuries not seen on computed tomographic (CT) scans. The trauma registry was used to identify and retrospectively review medical records of blunt trauma patients from January 1, 2005, to March 30, 2012. Only obtunded patients with a CT scan and MRI of the cervical spine were included. The study cohort consisted of 277 patients. In 13 (5%) patients, MRI detected clinically significant cervical spine injuries that were missed by CT scans, and in 7 (3%) these injuries required intervention. The number needed to screen with MRI to prevent 1 missed injury was 21. The findings suggest that the routine use of MRI in clearing the cervical spine in the obtunded blunt trauma patient. Copyright © 2013 Elsevier Inc. All rights reserved.
Keles, Papatya; Yuce, Ihsan; Keles, Sait; Kantarci, Mecit
2016-06-01
The aim of this study was to define the different courses and percentages of hepatic artery that were detected during preoperative evaluation of living liver donors by multidetector computed tomographic angiography (MDCTA). We evaluated 150 donors before hepatic transplantation. All of the donors were evaluated by multislice CT scan with 256 detectors. For each patient, arterial, portal and venous phase images were obtained. The hepatic arterial variations were evaluated by the same radiologist according to Michels' classification. Common hepatic arterial anatomy (type I) was observed in 95 donors (63.3%). Other arterial variations were determined in the remaining 55 donors (36.6%). The second common variation was type XI which did not match with the description of Michels' classification variation in 15 donors (10%). The remaining variations described in Michels' classification were seen at lower rates. Type VII or X variation was not seen. MDCTA is a useful method to identify the blood supply of the liver before the liver transplantations, and surgeons can make their plan on the basis of CT data.
Inflammatory Myofibroblastic Tumor Mimicking Apical Periodontitis.
Adachi, Makoto; Kiho, Kazuki; Sekine, Genta; Ohta, Takahisa; Matsubara, Makoto; Yoshida, Takakazu; Katsumata, Akitoshi; Tanuma, Jun-ichi; Sumitomo, Shinichiro
2015-12-01
Inflammatory myofibroblastic tumors (IMTs) are rare. IMTs of the head and neck occur in all age groups, from neonates to old age, with the highest incidence occurring in childhood and early adulthood. An IMT has been defined as a histologically distinctive lesion of uncertain behavior. This article describes an unusual case of IMT mimicking apical periodontitis in the mandible of a 42-year-old man. At first presentation, the patient showed spontaneous pain and percussion pain at teeth #28 to 30, which continued after initial endodontic treatment. Panoramic radiography revealed a radiolucent lesion at the site. Cone-beam computed tomographic imaging showed osteolytic lesions, suggesting an aggressive neoplasm requiring incisional biopsy. Histopathological examination indicated an IMT. The lesion was removed en bloc under general anesthesia, and the patient manifested no clinical evidence of recurrence for 24 months. Lesions of nonendodontic origin should be included in the differential diagnosis of apical periodontitis. Every available diagnostic tool should be used to confirm the diagnosis. Cone-beam computed tomographic imaging is very helpful for differential diagnosis in IMTs mimicking apical periodontitis. Copyright © 2015 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Bendyk-Szeffer, Maja; Łagocka, Ryta; Trusewicz, Matylda; Lipski, Mariusz; Buczkowska-Radlińska, Jadwiga
2015-02-01
An extensive perforating internal root resorption accompanied by apical periodontitis and odontogenic sinus mucositis was detected on preoperative cone-beam computed tomographic scans in a first maxillary molar. After the chemomechanical debridement of the root canals, calcium hydroxide was placed as a temporary dressing for 7 days. Mineral trioxide aggregate was used to fill the perforation site with the aid of a surgical microscope. At the next visit, the root with the resorption defect was filled with warm vertical compaction of gutta-percha. A control cone-beam computed tomographic scan acquired 6 months after the endodontic treatment revealed complete resolution of the sinus retention cyst. Moreover, the patient's frequent otolaryngologic disturbances ceased. The tooth was functional with satisfactory clinical and radiographic results after 12 months. Based on the results of this case, successful repair of an extensive, perforating internal resorption with mineral trioxide aggregate may lead to complete resolution of apical periodontitis and maxillary sinus retention cyst. Copyright © 2015 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
IDIOS: An innovative index for evaluating dental imaging-based osteoporosis screening indices
Halboub, Esam; Almashraqi, Abeer Abdulkareem; Khattab, Razan; Al Haffar, Iyad
2016-01-01
Purpose The goal of this study was to develop a new index as an objective reference for evaluating current and newly developed indices used for osteoporosis screening based on dental images. Its name; IDIOS, stands for Index of Dental-imaging Indices of Osteoporosis Screening. Materials and Methods A comprehensive PubMed search was conducted to retrieve studies on dental imaging-based indices for osteoporosis screening. The results of the eligible studies, along with other relevant criteria, were used to develop IDIOS, which has scores ranging from 0 (0%) to 15 (100%). The indices presented in the studies we included were then evaluated using IDIOS. Results The 104 studies that were included utilized 24, 4, and 9 indices derived from panoramic, periapical, and computed tomographic/cone-beam computed tomographic techniques, respectively. The IDIOS scores for these indices ranged from 0 (0%) to 11.75 (78.32%). Conclusion IDIOS is a valuable reference index that facilitates the evaluation of other dental imaging-based osteoporosis screening indices. Furthermore, IDIOS can be utilized to evaluate the accuracy of newly developed indices. PMID:27672615
Inspiratory and expiratory computed tomographic volumetry for lung volume reduction surgery.
Morimura, Yuki; Chen, Fengshi; Sonobe, Makoto; Date, Hiroshi
2013-06-01
Three-dimensional (3D) computed tomographic (CT) volumetry has been introduced into the field of thoracic surgery, and a combination of inspiratory and expiratory 3D-CT volumetry provides useful data on regional pulmonary function as well as the volume of individual lung lobes. We report herein a case of a 62-year-old man with severe emphysema who had undergone lung volume reduction surgery (LVRS) to assess this technique as a tool for the evaluation of regional lung function and volume before and after LVRS. His postoperative pulmonary function was maintained in good condition despite a gradual slight decrease 2 years after LVRS. This trend was also confirmed by a combination of inspiratory and expiratory 3D-CT volumetry. We confirm that a combination of inspiratory and expiratory 3D-CT volumetry might be effective for the preoperative assessment of LVRS in order to determine the amount of lung tissue to be resected as well as for postoperative evaluation. This novel technique could, therefore, be used more widely to assess local lung function.
Inspiratory and expiratory computed tomographic volumetry for lung volume reduction surgery
Morimura, Yuki; Chen, Fengshi; Sonobe, Makoto; Date, Hiroshi
2013-01-01
Three-dimensional (3D) computed tomographic (CT) volumetry has been introduced into the field of thoracic surgery, and a combination of inspiratory and expiratory 3D-CT volumetry provides useful data on regional pulmonary function as well as the volume of individual lung lobes. We report herein a case of a 62-year-old man with severe emphysema who had undergone lung volume reduction surgery (LVRS) to assess this technique as a tool for the evaluation of regional lung function and volume before and after LVRS. His postoperative pulmonary function was maintained in good condition despite a gradual slight decrease 2 years after LVRS. This trend was also confirmed by a combination of inspiratory and expiratory 3D-CT volumetry. We confirm that a combination of inspiratory and expiratory 3D-CT volumetry might be effective for the preoperative assessment of LVRS in order to determine the amount of lung tissue to be resected as well as for postoperative evaluation. This novel technique could, therefore, be used more widely to assess local lung function. PMID:23460599
Left main coronary artery stenosis: severity evaluation and implications for management.
Habibi, Susan E; Shah, Rahman; Berzingi, Chalak O; Melchior, Ryan; Sumption, Kevin F; Jovin, Ion S
2017-03-01
The significant stenosis of the left main coronary artery is associated with poor outcomes and is considered a strong indication for revascularization. However, deciding whether the stenosis is significant can sometimes be challenging, especially when the degree of stenosis is intermediate, and can necessitate additional tests and imaging modalities. Areas covered: We did a literature search using keywords like 'left main', 'imaging', 'intravascular ultrasound', 'fractional flow reserve', 'computed tomographic angiography' and 'magnetic resonance imaging'. The most commonly used methods for better characterizing intermediate left main coronary stenoses are intravascular ultrasound and fractional flow reserve, while optical coherence tomography is the newer technique that provides better images, but for which not as much data is available. The noninvasive techniques are coronary computed tomographic angiography and, to a lesser degree, coronary magnetic resonance imaging. Expert commentary: Accurately determining the severity of left main coronary stenosis can mean the difference between a major intervention and conservative therapy. The reviewed newer imaging modalities give us greater confidence that patients with left main stenosis are assigned to the right treatment modality.
Opolski, Maksymilian P; Debski, Artur; Borucki, Bartosz A; Szpak, Marcin; Staruch, Adam D; Kepka, Cezary; Witkowski, Adam
2016-06-01
We report a case of successful computed tomography-guided percutaneous revascularization of a chronically occluded right coronary artery using a wearable, hands-free computer with a head-mounted display worn by interventional cardiologists in the catheterization laboratory. The projection of 3-dimensional computed tomographic reconstructions onto the screen of virtual reality glass allowed the operators to clearly visualize the distal coronary vessel, and verify the direction of the guide wire advancement relative to the course of the occluded vessel segment. This case provides proof of concept that wearable computers can improve operator comfort and procedure efficiency in interventional cardiology. Copyright © 2016 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.
Two methods of Haustral fold detection from computed tomographic virtual colonoscopy images
NASA Astrophysics Data System (ADS)
Chowdhury, Ananda S.; Tan, Sovira; Yao, Jianhua; Linguraru, Marius G.; Summers, Ronald M.
2009-02-01
Virtual colonoscopy (VC) has gained popularity as a new colon diagnostic method over the last decade. VC is a new, less invasive alternative to the usually practiced optical colonoscopy for colorectal polyp and cancer screening, the second major cause of cancer related deaths in industrial nations. Haustral (colonic) folds serve as important landmarks for virtual endoscopic navigation in the existing computer-aided-diagnosis (CAD) system. In this paper, we propose and compare two different methods of haustral fold detection from volumetric computed tomographic virtual colonoscopy images. The colon lumen is segmented from the input using modified region growing and fuzzy connectedness. The first method for fold detection uses a level set that evolves on a mesh representation of the colon surface. The colon surface is obtained from the segmented colon lumen using the Marching Cubes algorithm. The second method for fold detection, based on a combination of heat diffusion and fuzzy c-means algorithm, is employed on the segmented colon volume. Folds obtained on the colon volume using this method are then transferred to the corresponding colon surface. After experimentation with different datasets, results are found to be promising. The results also demonstrate that the first method has a tendency of slight under-segmentation while the second method tends to slightly over-segment the folds.
He, Jian; Gan, Weidong; Liu, Song; Zhou, Kefeng; Zhang, Gutian; Guo, Hongqian; Zhu, Bin
2015-01-01
To investigate the dynamic contrast-enhanced computed tomography (CT) characteristics of renal cell carcinoma associated with Xp11.2 translocation and TFE gene fusion (Xp11.2 RCC) by comparison with clear cell renal cell carcinoma (CCRCC). Dynamic contrast-enhanced CT images and clinical and pathological records of 20 adult patients with Xp11.2 RCC confirmed by TFE3 immunohistochemical and fluorescence in situ hybridization assay were retrospectively analyzed and compared with the findings of 21 contemporary CCRCCs. Renal cell carcinoma associated with Xp11.2 translocation and TFE gene fusions often occurred in young (30.6 ± 8.6 years) patients with hematuria (9/20). They presented as well-defined (17/20) cystic-solid (17/20) mass with hemorrhage (8/20) and circular/rim calcifications (6/20). Dynamic contrast-enhanced CT showed heterogeneous moderate prolonged enhancement. A tumor-to-cortex attenuation ratio in corticomedullary phase less than 0.62 gave a sensitivity of 90.0% and a specificity of 92.9% in differentiating Xp11.2 RCC from CCRCC (area under the receiver operating characteristic curve = 0.957, P < 0.001). Computed tomographic characteristics and dynamic contrast-enhanced patterns and index can differentiate Xp11.2 RCC from CCRCC.
Soh, Shui-Boon; Pham, Alan; O'Hehir, Robyn E; Cherk, Martin; Topliss, Duncan J
2013-09-01
A 42-year-old woman presented with a rapidly enlarging right-sided thyroid mass and underwent hemithyroidectomy. Riedel's thyroiditis was only diagnosed upon surgical decompression of the right carotid artery 2 years later. She became more symptomatic as Riedel's thyroiditis progressed, and mediastinal fibrosclerosis developed over the next 12 months. Oral prednisolone failed to improve her condition, and she was commenced on tamoxifen. Despite initial improvement, her symptoms recurred 2 years later, mainly arising from compression of the trachea and esophagus at the thoracic inlet. Fluorodeoxyglucose positron emission tomographic scan showed locally advanced active invasive fibrosclerosis in the neck and mediastinum. An elevated activin-A level of 218 pg/mL was consistent with active inflammation. IgG subtypes (including IgG4) were normal. Two courses of iv methylprednisolone were given but only produced transient improvement. Subsequently, the patient received 3 doses of i.v. rituximab at monthly intervals and had prompt sustained symptomatic improvement. Activin-A level decreased to 122 pg/mL 10 months after rituximab therapy. Fluorodeoxyglucose positron emission tomographic scan 6 weeks after therapy showed reduction in inflammation. A further scan at 10 months demonstrated ongoing response to rituximab. This is a case of refractory Riedel's thyroiditis with symptomatic, biochemical, and radiological improvement that has persisted 14 months after rituximab. The likelihood and duration of response to rituximab in Riedel's thyroiditis requires further study.
Giacomelli, L; Conroy, S; Gorini, G; Horton, L; Murari, A; Popovichev, S; Syme, D B
2014-02-01
The Joint European Torus (JET, Culham, UK) is the largest tokamak in the world devoted to nuclear fusion experiments of magnetic confined Deuterium (D)/Deuterium-Tritium (DT) plasmas. Neutrons produced in these plasmas are measured using various types of neutron detectors and spectrometers. Two of these instruments on JET make use of organic liquid scintillator detectors. The neutron emission profile monitor implements 19 liquid scintillation counters to detect the 2.45 MeV neutron emission from D plasmas. A new compact neutron spectrometer is operational at JET since 2010 to measure the neutron energy spectra from both D and DT plasmas. Liquid scintillation detectors are sensitive to both neutron and gamma radiation but give light responses of different decay time such that pulse shape discrimination techniques can be applied to identify the neutron contribution of interest from the data. The most common technique consists of integrating the radiation pulse shapes within different ranges of their rising and/or trailing edges. In this article, a step forward in this type of analysis is presented. The method applies a tomographic analysis of the 3-dimensional neutron and gamma pulse shape and pulse height distribution data obtained from liquid scintillation detectors such that n/γ discrimination can be improved to lower energies and additional information can be gained on neutron contributions to the gamma events and vice versa.
Seismic tomography of the southern California crust based on spectral-element and adjoint methods
NASA Astrophysics Data System (ADS)
Tape, Carl; Liu, Qinya; Maggi, Alessia; Tromp, Jeroen
2010-01-01
We iteratively improve a 3-D tomographic model of the southern California crust using numerical simulations of seismic wave propagation based on a spectral-element method (SEM) in combination with an adjoint method. The initial 3-D model is provided by the Southern California Earthquake Center. The data set comprises three-component seismic waveforms (i.e. both body and surface waves), filtered over the period range 2-30 s, from 143 local earthquakes recorded by a network of 203 stations. Time windows for measurements are automatically selected by the FLEXWIN algorithm. The misfit function in the tomographic inversion is based on frequency-dependent multitaper traveltime differences. The gradient of the misfit function and related finite-frequency sensitivity kernels for each earthquake are computed using an adjoint technique. The kernels are combined using a source subspace projection method to compute a model update at each iteration of a gradient-based minimization algorithm. The inversion involved 16 iterations, which required 6800 wavefield simulations. The new crustal model, m16, is described in terms of independent shear (VS) and bulk-sound (VB) wave speed variations. It exhibits strong heterogeneity, including local changes of +/-30 per cent with respect to the initial 3-D model. The model reveals several features that relate to geological observations, such as sedimentary basins, exhumed batholiths, and contrasting lithologies across faults. The quality of the new model is validated by quantifying waveform misfits of full-length seismograms from 91 earthquakes that were not used in the tomographic inversion. The new model provides more accurate synthetic seismograms that will benefit seismic hazard assessment.
Adjoint Tomography of the Southern California Crust (Invited) (Invited)
NASA Astrophysics Data System (ADS)
Tape, C.; Liu, Q.; Maggi, A.; Tromp, J.
2009-12-01
We iteratively improve a three-dimensional tomographic model of the southern California crust using numerical simulations of seismic wave propagation based on a spectral-element method (SEM) in combination with an adjoint method. The initial 3D model is provided by the Southern California Earthquake Center. The dataset comprises three-component seismic waveforms (i.e. both body and surface waves), filtered over the period range 2-30 s, from 143 local earthquakes recorded by a network of 203 stations. Time windows for measurements are automatically selected by the FLEXWIN algorithm. The misfit function in the tomographic inversion is based on frequency-dependent multitaper traveltime differences. The gradient of the misfit function and related finite-frequency sensitivity kernels for each earthquake are computed using an adjoint technique. The kernels are combined using a source subspace projection method to compute a model update at each iteration of a gradient-based minimization algorithm. The inversion involved 16 iterations, which required 6800 wavefield simulations and a total of 0.8 million CPU hours. The new crustal model, m16, is described in terms of independent shear (Vs) and bulk-sound (Vb) wavespeed variations. It exhibits strong heterogeneity, including local changes of ±30% with respect to the initial 3D model. The model reveals several features that relate to geologic observations, such as sedimentary basins, exhumed batholiths, and contrasting lithologies across faults. The quality of the new model is validated by quantifying waveform misfits of full-length seismograms from 91 earthquakes that were not used in the tomographic inversion. The new model provides more accurate synthetic seismograms that will benefit seismic hazard assessment.
2001-10-25
a CT image, each voxel contains an integer number which is the CT value, in Hounsfield units (HU), of the voxel. Therefore, the standard method of...Task Number Work Unit Number Performing Organization Name(s) and Address(es) Department of Electrical and Computer Engineering, University of...34, Journal of Pediatric Surgery, vol 24(7), pp. 708-711, 1989. [4] I. N. Bankman, editor, Handbook of Medical Image Analysis, Academic Press, London, UK
Computed tomographic analysis of deformity and dimensional changes in the eyeball
DOE Office of Scientific and Technical Information (OSTI.GOV)
Osborne, D.R.; Foulks, G.N.
1984-12-01
Computed tomography (CT) was performed in 40 patients with a confirmed ophthalmic diagnosis and a change in the dimensions or configuration of the eyeball. Abnormalities studied included coloboma, microphthalmus, buphthalmos, axial myopia, macrophthalmus, phthisis bulbi, trauma, neoplasm, posterior staphyloma, granuloma, pseudotumor, and surgicalscleral banding for retinal detachment. CT findings could be grouped into three categories depending upon whether the eye was small, large, or normal in size, with the findings in each group allowing distinction of most disease processes.
Computer tomography of flows external to test models
NASA Technical Reports Server (NTRS)
Prikryl, I.; Vest, C. M.
1982-01-01
Computer tomographic techniques for reconstruction of three-dimensional aerodynamic density fields, from interferograms recorded from several different viewing directions were studied. Emphasis is on the case in which an opaque object such as a test model in a wind tunnel obscures significant regions of the interferograms (projection data). A method called the Iterative Convolution Method (ICM), existing methods in which the field is represented by a series expansions, and analysis of real experimental data in the form of aerodynamic interferograms are discussed.
Model studies of laser absorption computed tomography for remote air pollution measurement
NASA Technical Reports Server (NTRS)
Wolfe, D. C., Jr.; Byer, R. L.
1982-01-01
Model studies of the potential of laser absorption-computed tomography are presented which demonstrate the possibility of sensitive remote atmospheric pollutant measurements, over kilometer-sized areas, with two-dimensional resolution, at modest laser source powers. An analysis of this tomographic reconstruction process as a function of measurement SNR, laser power, range, and system geometry, shows that the system is able to yield two-dimensional maps of pollutant concentrations at ranges and resolutions superior to those attainable with existing, direct-detection laser radars.
Advances in target imaging of deep Earth structure
NASA Astrophysics Data System (ADS)
Masson, Y.; Romanowicz, B. A.; Clouzet, P.
2015-12-01
A new generation of global tomographic models (Lekić and Romanowicz, 2011; French et al, 2013, 2014) has emerged with the development of accurate numerical wavefield computations in a 3D earth combined with access to enhanced HPC capabilities. These models have sharpened up mantle images and unveiled relatively small scale structures that were blurred out in previous generation models. Fingerlike structures have been found at the base of the oceanic asthenosphere, and vertically oriented broad low velocity plume conduits extend throughout the lower mantle beneath those major hotspots that are located within the perimeter of the deep mantle large low shear velocity provinces (LLSVPs). While providing new insights into our understanding of mantle dynamics, the detailed morphology of these features, requires further efforts to obtain higher resolution images. The focus of our ongoing effort is to develop advanced tomographic methods to image remote regions of the Earth at fine scales. We have developed an approach in which distant sources (located outside of the target region) are replaced by an equivalent set of local sources located at the border of the computational domain (Masson et al., 2014). A limited number of global simulations in a reference 3D earth model is then required. These simulations are computed prior to the regional inversion, while iterations of the model need to be performed only within the region of interest, potentially allowing us to include shorter periods at limited additional computational cost. Until now, the application was limited to a distribution of receivers inside the target region. This is particularly suitable for studies of upper mantle structure in regions with dense arrays (e.g. see our companion presentation Clouzet et al., this Fall AGU). Here we present our latest development that now can include teleseismic data recorded outside the imaged region. This allows us to perform regional waveform tomography in the situation where neither earthquakes nor seismological stations are present within the region of interest, such as would be desireable for the study of a region in the deep mantle. We present benchmark tests showing how the uncertainties in the reference 3D model employed outside of the target region affects the quality of the regional tomographic images obtained.
Portable imaging system method and apparatus
Freifeld, Barry M.; Kneafsley, Timothy J.; Pruess, Jacob; Tomutsa, Liviu; Reiter, Paul A.; deCastro, Ted M.
2006-07-25
An operator shielded X-ray imaging system has sufficiently low mass (less than 300 kg) and is compact enough to enable portability by reducing operator shielding requirements to a minimum shielded volume. The resultant shielded volume may require a relatively small mass of shielding in addition to the already integrally shielded X-ray source, intensifier, and detector. The system is suitable for portable imaging of well cores at remotely located well drilling sites. The system accommodates either small samples, or small cross-sectioned objects of unlimited length. By rotating samples relative to the imaging device, the information required for computer aided tomographic reconstruction may be obtained. By further translating the samples relative to the imaging system, fully three dimensional (3D) tomographic reconstructions may be obtained of samples having arbitrary length.
Accuracy of Computed Tomographic Perfusion in Diagnosis of Brain Death: A Prospective Cohort Study.
Sawicki, Marcin; Sołek-Pastuszka, Joanna; Chamier-Ciemińska, Katarzyna; Walecka, Anna; Bohatyrewicz, Romuald
2018-05-04
BACKGROUND This study was designed to determine diagnostic accuracy of computed tomographic perfusion (CTP) compared to computed tomographic angiography (CTA) for the diagnosis of brain death (BD). MATERIAL AND METHODS Whole-brain CTP was performed in patients diagnosed with BD and in patients with devastating brain injury with preserved brainstem reflexes. CTA was derived from CTP datasets. Cerebral blood flow (CBF) and volume (CBV) were calculated in all brain regions. CTP findings were interpreted as confirming diagnosis of BD (positive) when CBF and CBV in all ROIs were below 10 mL/100 g/min and 1.0 mL/100 g, respectively. CTA findings were interpreted using a 4-point system. RESULTS Fifty brain-dead patients and 5 controls were included. In brain-dead patients, CTP results revealed CBF 0.00-9.98 mL/100 g/min and CBV 0.00-0.99 mL/100 g, and were thus interpreted as positive in all patients. CTA results suggested 7 negative cases, providing 86% sensitivity. In the non-brain-dead group, CTP results revealed CBF 2.37-37.59 mL/100 g/min and CBV 0.73-2.34 mL/100 g. The difference between values of CBF and CBV in the brain-dead and non-brain-dead groups was statistically significant (p=0.002 for CBF and p=0.001 for CBV). CTP findings in all non-brain-dead patients were interpreted as negative. This resulted in a specificity of 100% (95% CI, 0.31-1.00) for CTP in the diagnosis of BD. In all non-brain-dead patients, CTA revealed preserved intracranial filling and was interpreted as negative. This resulted in a specificity of 100% (95% CI, 0.31-1.00) for CTA in diagnosis of BD. CONCLUSIONS Whole-brain CTP seems to be a highly sensitive and specific method in diagnosis of BD.
Ji, Ming-Liang; Qian, Bang-ping; Qiu, Yong; Wang, Bin; Zhu, Ze-zhang; Yu, Yang; Jiang, Jun
2013-10-15
A computed tomographic study. To investigate the change in aortic length in patients with ankylosing spondylitis (AS) with thoracolumbar kyphosis after closing-opening wedge osteotomy (COWO). Several previous studies reported that COWO can effectively correct severe thoracolumbar kyphosis caused by AS. However, one disadvantage of COWO is elongation of the aorta, which increases the risk of aortic injury. To date, no studies have analyzed the alteration in aortic length in patients with AS undergoing COWO for thoracolumbar kyphosis. A total of 21 consecutive patients with AS with a mean age of 38.9 years undergoing COWO for the correction of thoracolumbar kyphosis were retrospectively studied. Radiographical measurements included global kyphosis, thoracic kyphosis, lumbar lordosis, angle of fusion levels, local kyphosis, and anterior height of the osteotomized vertebra. The computed tomographic scans of the spine were used to measure the aortic diameter (at the site of the osteotomy) and length (the length between the superior endplate of the upper instrumented vertebra and the inferior endplate of L4). The aortic length increased by an average of 2.2 cm postoperatively. Significant changes in global kyphosis, local kyphosis, angle of fusion levels, lumbar lordosis, anterior height of the osteotomized vertebra, and aortic diameter at the site of the osteotomy were observed (P < 0.01). Significant correlation was noted between aortic length and changes in global kyphosis (r = 0.525, P = 0.015), local kyphosis (r = 0.654, P = 0.001), angle of fusion levels (r = 0.634, P = 0.002), and lumbar lordosis (r = 0.538, P = 0.012). Aortic lengthening after COWO for correction of kyphosis was quantitatively confirmed by this study. Spine surgeons should be aware of the potential risk for the development of aortic injury in patients with AS undergoing COWO for the correction of thoracolumbar kyphosis. 4.
Ji, Ming-Liang; Qian, Bang-Ping; Qiu, Yong; Wang, Bin; Mao, Sai-Hu; Zhu, Ze-Zhang; Yu, Yang
2015-12-01
A computed tomographic study. To investigate the change in abdominal morphology in surgically treated patients with ankylosing spondylitis (AS) and thoracolumbar kyphosis. Severe thoracolumbar kyphosis in patients with AS exerts pressure on the abdominal cavity and subsequently causes intra-abdominal complications. Several spinal osteotomy techniques have been widely used to correct AS-related thoracolumbar kyphosis. To date, the changed abdominal morphology in patients with AS undergoing surgical correction of thoracolumbar kyphosis has not been addressed. A total of 29 patients with AS undergoing lumbar pedicle subtraction osteotomy for correction of thoracolumbar kyphosis were retrospectively reviewed. Computed tomographic scans of the spine were used to measure the longitudinal, transverse, and anterior-posterior diameters of the abdominal cavity. Furthermore, the abdominal cavity was considered as an ellipsoid structure, thereby allowing calculation of its volume. Radiographical evaluations included global kyphosis (GK), thoracic kyphosis, lumbar lordosis (LL), and angle of fusion levels (AFL). The longitudinal diameter of abdominal cavity significantly increased (P < 0.01), whereas the transverse and anterior-posterior diameters of the abdominal cavity did not change, postoperatively (P > 0.05). Significant changes in GK, LL, and AFL were observed (P < 0.01). The abdominal cavity volume (ACV) increased by an average of 652 mL. The change in ACV was significantly correlated with the changes in GK (r = 0.453, P = 0.014), LL (r = 0.42, P = 0.023), and AFL (r = 0.388, P = 0.037). The increased ACV after correction of thoracolumbar kyphosis was quantitatively confirmed by this study. Thus, the improvement in digestive function after correction of thoracolumbar kyphosis secondary to AS, which has been previously documented, may be because of an increase in ACV. Moreover, spine surgeons should be aware of the potential risk for the development of abdominal complications caused by the lengthening of longitudinal diameter of the abdominal cavity. 3.
Wave Propagation in Non-Stationary Statistical Mantle Models at the Global Scale
NASA Astrophysics Data System (ADS)
Meschede, M.; Romanowicz, B. A.
2014-12-01
We study the effect of statistically distributed heterogeneities that are smaller than the resolution of current tomographic models on seismic waves that propagate through the Earth's mantle at teleseismic distances. Current global tomographic models are missing small-scale structure as evidenced by the failure of even accurate numerical synthetics to explain enhanced coda in observed body and surface waveforms. One way to characterize small scale heterogeneity is to construct random models and confront observed coda waveforms with predictions from these models. Statistical studies of the coda typically rely on models with simplified isotropic and stationary correlation functions in Cartesian geometries. We show how to construct more complex random models for the mantle that can account for arbitrary non-stationary and anisotropic correlation functions as well as for complex geometries. Although this method is computationally heavy, model characteristics such as translational, cylindrical or spherical symmetries can be used to greatly reduce the complexity such that this method becomes practical. With this approach, we can create 3D models of the full spherical Earth that can be radially anisotropic, i.e. with different horizontal and radial correlation functions, and radially non-stationary, i.e. with radially varying model power and correlation functions. Both of these features are crucial for a statistical description of the mantle in which structure depends to first order on the spherical geometry of the Earth. We combine different random model realizations of S velocity with current global tomographic models that are robust at long wavelengths (e.g. Meschede and Romanowicz, 2014, GJI submitted), and compute the effects of these hybrid models on the wavefield with a spectral element code (SPECFEM3D_GLOBE). We finally analyze the resulting coda waves for our model selection and compare our computations with observations. Based on these observations, we make predictions about the strength of unresolved small-scale structure and extrinsic attenuation.
NASA Astrophysics Data System (ADS)
Chiarabba, C.; Giacomuzzi, G.; Piana Agostinetti, N.
2017-12-01
The San Andreas Fault (SAF) near Parkfield is the best known fault section which exhibit a clear transition in slip behavior from stable to unstable. Intensive monitoring and decades of studies permit to identify details of these processes with a good definition of fault structure and subsurface models. Tomographic models computed so far revealed the existence of large velocity contrasts, yielding physical insight on fault rheology. In this study, we applied a recently developed full non-linear tomography method to compute Vp and Vs models which focus on the section of the fault that exhibit fault slip transition. The new tomographic code allows not to impose a vertical seismic discontinuity at the fault position, as routinely done in linearized codes. Any lateral velocity contrast found is directly dictated by the data themselves and not imposed by subjective choices. The use of the same dataset of previous tomographic studies allows a proper comparison of results. We use a total of 861 earthquakes, 72 blasts and 82 shots and the overall arrival time dataset consists of 43948 P- and 29158 S-wave arrival times, accurately selected to take care of seismic anisotropy. Computed Vp and Vp/Vs models, which by-pass the main problems related to linarized LET algorithms, excellently match independent available constraints and show crustal heterogeneities with a high resolution. The high resolution obtained in the fault surroundings permits to infer lateral changes of Vp and Vp/Vs across the fault (velocity gradient). We observe that stable and unstable sliding sections of the SAF have different velocity gradients, small and negligible in the stable slip segment, but larger than 15 % in the unstable slip segment. Our results suggest that Vp and Vp/Vs gradients across the fault control fault rheology and the attitude of fault slip behavior.
Lüders, Jürgen C; Steinmetz, Michael P; Mayberg, Marc R
2005-01-01
Infectious (mycotic) aneurysms that do not resolve with medical treatment require surgical obliteration, usually requiring sacrifice of the parent artery. In addition, patients with mycotic aneurysms frequently need subsequent cardiac valve repair, which often necessitates anticoagulation. Three cases of awake craniotomy for microsurgical clipping of mycotic aneurysms are presented. Awake minimally invasive craniotomy using frameless stereotactic guidance on the basis of computed tomographic angiography enables temporary occlusion of the parent artery with neurological assessment before obliteration of the aneurysm. A 56-year-old woman presented with progressively worsening mitral valve disease and a history of subacute bacterial endocarditis and subarachnoid hemorrhage 30 years previously. A cerebral angiogram revealed a 4-mm left middle cerebral artery (MCA) angular branch aneurysm, which required obliteration before mitral valve replacement. The second patient, a 64-year-old woman with a history of rheumatic fever, had an 8-mm right distal MCA aneurysm diagnosed in the setting of pulmonary abscess and worsening cardiac function as a result of mitral valve disease. The third patient, a 57-year-old man with a history of fevers, night sweats, and progressive mitral valve disease, had an enlarging left MCA angular branch aneurysm despite the administration of antibiotics. Because of their location on distal MCA branches, none of the aneurysms were amenable to preoperative test balloon occlusion. After undergoing stereotactic computed tomographic angiography with fiducial markers, the patients underwent a minimally invasive awake craniotomy with frameless stereotactic navigation. In all cases, the results of the neurological examination were unchanged during temporary parent artery occlusion and the aneurysms were successfully obliterated. Awake minimally invasive craniotomy for an infectious aneurysm located in eloquent brain enables awake testing before permanent clipping or vessel sacrifice. Combining frameless stereotactic navigation with computed tomographic angiography allowed us to perform the operation quickly through a small craniotomy with minimal exploration.
Lin, Hsiu-Hsia; Chuang, Ya-Fang; Weng, Jing-Ling; Lo, Lun-Jou
2015-01-01
Background Three-dimensional computed tomographic imaging has become popular in clinical evaluation, treatment planning, surgical simulation, and outcome assessment for maxillofacial intervention. The purposes of this study were to investigate whether there is any correlation among landmark-based horizontal reference planes and to validate the reproducibility and reliability of landmark identification. Materials and Methods Preoperative and postoperative cone-beam computed tomographic images of patients who had undergone orthognathic surgery were collected. Landmark-oriented reference planes including the Frankfort horizontal plane (FHP) and the lateral semicircular canal plane (LSP) were established. Four FHPs were defined by selecting 3 points from the orbitale, porion, or midpoint of paired points. The LSP passed through both the lateral semicircular canal points and nasion. The distances between the maxillary or mandibular teeth and the reference planes were measured, and the differences between the 2 sides were calculated and compared. The precision in locating the landmarks was evaluated by performing repeated tests, and the intraobserver reproducibility and interobserver reliability were assessed. Results A total of 30 patients with facial deformity and malocclusion—10 patients with facial symmetry, 10 patients with facial asymmetry, and 10 patients with cleft lip and palate—were recruited. Comparing the differences among the 5 reference planes showed no statistically significant difference among all patient groups. Regarding intraobserver reproducibility, the mean differences in the 3 coordinates varied from 0 to 0.35 mm, with correlation coefficients between 0.96 and 1.0, showing high correlation between repeated tests. Regarding interobserver reliability, the mean differences among the 3 coordinates varied from 0 to 0.47 mm, with correlation coefficients between 0.88 and 1.0, exhibiting high correlation between the different examiners. Conclusions The 5 horizontal reference planes were reliable and comparable for 3D craniomaxillofacial analysis. These reference planes were useful in standardizing the orientation of 3D skull models. PMID:25668209
Lin, Hsiu-Hsia; Chuang, Ya-Fang; Weng, Jing-Ling; Lo, Lun-Jou
2015-01-01
Three-dimensional computed tomographic imaging has become popular in clinical evaluation, treatment planning, surgical simulation, and outcome assessment for maxillofacial intervention. The purposes of this study were to investigate whether there is any correlation among landmark-based horizontal reference planes and to validate the reproducibility and reliability of landmark identification. Preoperative and postoperative cone-beam computed tomographic images of patients who had undergone orthognathic surgery were collected. Landmark-oriented reference planes including the Frankfort horizontal plane (FHP) and the lateral semicircular canal plane (LSP) were established. Four FHPs were defined by selecting 3 points from the orbitale, porion, or midpoint of paired points. The LSP passed through both the lateral semicircular canal points and nasion. The distances between the maxillary or mandibular teeth and the reference planes were measured, and the differences between the 2 sides were calculated and compared. The precision in locating the landmarks was evaluated by performing repeated tests, and the intraobserver reproducibility and interobserver reliability were assessed. A total of 30 patients with facial deformity and malocclusion--10 patients with facial symmetry, 10 patients with facial asymmetry, and 10 patients with cleft lip and palate--were recruited. Comparing the differences among the 5 reference planes showed no statistically significant difference among all patient groups. Regarding intraobserver reproducibility, the mean differences in the 3 coordinates varied from 0 to 0.35 mm, with correlation coefficients between 0.96 and 1.0, showing high correlation between repeated tests. Regarding interobserver reliability, the mean differences among the 3 coordinates varied from 0 to 0.47 mm, with correlation coefficients between 0.88 and 1.0, exhibiting high correlation between the different examiners. The 5 horizontal reference planes were reliable and comparable for 3D craniomaxillofacial analysis. These reference planes were useful in standardizing the orientation of 3D skull models.
Water vapour tomography using GPS phase observations: Results from the ESCOMPTE experiment
NASA Astrophysics Data System (ADS)
Nilsson, T.; Gradinarsky, L.; Elgered, G.
2007-10-01
Global Positioning System (GPS) tomography is a technique for estimating the 3-D structure of the atmospheric water vapour using data from a dense local network of GPS receivers. Several current methods utilize estimates of slant wet delays between the GPS satellites and the receivers on the ground, which are difficult to obtain with millimetre accuracy from the GPS observations. We present results of applying a new tomographic method to GPS data from the Expériance sur site pour contraindre les modèles de pollution atmosphérique et de transport d'emissions (ESCOMPTE) experiment in southern France. This method does not rely on any slant wet delay estimates, instead it uses the GPS phase observations directly. We show that the estimated wet refractivity profiles estimated by this method is on the same accuracy level or better compared to other tomographic methods. The results are in agreement with earlier simulations, for example the profile information is limited above 4 km.
Betts, Aislinn M; McGoldrick, Matthew T; Dethlefs, Christopher R; Piotrowicz, Justin; Van Avermaete, Tony; Maki, Jeff; Gerstler, Steve; Leevy, W M
2017-04-25
Biomedical imaging modalities like computed tomography (CT) and magnetic resonance (MR) provide excellent platforms for collecting three-dimensional data sets of patient or specimen anatomy in clinical or preclinical settings. However, the use of a virtual, on-screen display limits the ability of these tomographic images to fully convey the anatomical information embedded within. One solution is to interface a biomedical imaging data set with 3D printing technology to generate a physical replica. Here we detail a complementary method to visualize tomographic imaging data with a hand-held model: Sub Surface Laser Engraving (SSLE) of crystal glass. SSLE offers several unique benefits including: the facile ability to include anatomical labels, as well as a scale bar; streamlined multipart assembly of complex structures in one medium; high resolution in the X, Y, and Z planes; and semi-transparent shells for visualization of internal anatomical substructures. Here we demonstrate the process of SSLE with CT data sets derived from pre-clinical and clinical sources. This protocol will serve as a powerful and inexpensive new tool with which to visualize complex anatomical structures for scientists and students in a number of educational and research settings.
Computational adaptive optics for broadband optical interferometric tomography of biological tissue.
Adie, Steven G; Graf, Benedikt W; Ahmad, Adeel; Carney, P Scott; Boppart, Stephen A
2012-05-08
Aberrations in optical microscopy reduce image resolution and contrast, and can limit imaging depth when focusing into biological samples. Static correction of aberrations may be achieved through appropriate lens design, but this approach does not offer the flexibility of simultaneously correcting aberrations for all imaging depths, nor the adaptability to correct for sample-specific aberrations for high-quality tomographic optical imaging. Incorporation of adaptive optics (AO) methods have demonstrated considerable improvement in optical image contrast and resolution in noninterferometric microscopy techniques, as well as in optical coherence tomography. Here we present a method to correct aberrations in a tomogram rather than the beam of a broadband optical interferometry system. Based on Fourier optics principles, we correct aberrations of a virtual pupil using Zernike polynomials. When used in conjunction with the computed imaging method interferometric synthetic aperture microscopy, this computational AO enables object reconstruction (within the single scattering limit) with ideal focal-plane resolution at all depths. Tomographic reconstructions of tissue phantoms containing subresolution titanium-dioxide particles and of ex vivo rat lung tissue demonstrate aberration correction in datasets acquired with a highly astigmatic illumination beam. These results also demonstrate that imaging with an aberrated astigmatic beam provides the advantage of a more uniform depth-dependent signal compared to imaging with a standard gaussian beam. With further work, computational AO could enable the replacement of complicated and expensive optical hardware components with algorithms implemented on a standard desktop computer, making high-resolution 3D interferometric tomography accessible to a wider group of users and nonspecialists.
Computer-aided marginal artery detection on computed tomographic colonography
NASA Astrophysics Data System (ADS)
Wei, Zhuoshi; Yao, Jianhua; Wang, Shijun; Liu, Jiamin; Summers, Ronald M.
2012-03-01
Computed tomographic colonography (CTC) is a minimally invasive technique for colonic polyps and cancer screening. The marginal artery of the colon, also known as the marginal artery of Drummond, is the blood vessel that connects the inferior mesenteric artery with the superior mesenteric artery. The marginal artery runs parallel to the colon for its entire length, providing the blood supply to the colon. Detecting the marginal artery may benefit computer-aided detection (CAD) of colonic polyp. It can be used to identify teniae coli based on their anatomic spatial relationship. It can also serve as an alternative marker for colon localization, in case of colon collapse and inability to directly compute the endoluminal centerline. This paper proposes an automatic method for marginal artery detection on CTC. To the best of our knowledge, this is the first work presented for this purpose. Our method includes two stages. The first stage extracts the blood vessels in the abdominal region. The eigenvalue of Hessian matrix is used to detect line-like structures in the images. The second stage is to reduce the false positives in the first step. We used two different masks to exclude the false positive vessel regions. One is a dilated colon mask which is obtained by colon segmentation. The other is an eroded visceral fat mask which is obtained by fat segmentation in the abdominal region. We tested our method on a CTC dataset with 6 cases. Using ratio-of-overlap with manual labeling of the marginal artery as the standard-of-reference, our method yielded true positive, false positive and false negative fractions of 89%, 33%, 11%, respectively.
Sorensen, Mads Solvsten; Mosegaard, Jesper; Trier, Peter
2009-06-01
Existing virtual simulators for middle ear surgery are based on 3-dimensional (3D) models from computed tomographic or magnetic resonance imaging data in which image quality is limited by the lack of detail (maximum, approximately 50 voxels/mm3), natural color, and texture of the source material.Virtual training often requires the purchase of a program, a customized computer, and expensive peripherals dedicated exclusively to this purpose. The Visible Ear freeware library of digital images from a fresh-frozen human temporal bone was segmented, and real-time volume rendered as a 3D model of high-fidelity, true color, and great anatomic detail and realism of the surgically relevant structures. A haptic drilling model was developed for surgical interaction with the 3D model. Realistic visualization in high-fidelity (approximately 125 voxels/mm3) and true color, 2D, or optional anaglyph stereoscopic 3D was achieved on a standard Core 2 Duo personal computer with a GeForce 8,800 GTX graphics card, and surgical interaction was provided through a relatively inexpensive (approximately $2,500) Phantom Omni haptic 3D pointing device. This prototype is published for download (approximately 120 MB) as freeware at http://www.alexandra.dk/ves/index.htm.With increasing personal computer performance, future versions may include enhanced resolution (up to 8,000 voxels/mm3) and realistic interaction with deformable soft tissue components such as skin, tympanic membrane, dura, and cholesteatomas-features some of which are not possible with computed tomographic-/magnetic resonance imaging-based systems.
Castaño-Díez, Daniel
2017-01-01
Dynamo is a package for the processing of tomographic data. As a tool for subtomogram averaging, it includes different alignment and classification strategies. Furthermore, its data-management module allows experiments to be organized in groups of tomograms, while offering specialized three-dimensional tomographic browsers that facilitate visualization, location of regions of interest, modelling and particle extraction in complex geometries. Here, a technical description of the package is presented, focusing on its diverse strategies for optimizing computing performance. Dynamo is built upon mbtools (middle layer toolbox), a general-purpose MATLAB library for object-oriented scientific programming specifically developed to underpin Dynamo but usable as an independent tool. Its structure intertwines a flexible MATLAB codebase with precompiled C++ functions that carry the burden of numerically intensive operations. The package can be delivered as a precompiled standalone ready for execution without a MATLAB license. Multicore parallelization on a single node is directly inherited from the high-level parallelization engine provided for MATLAB, automatically imparting a balanced workload among the threads in computationally intense tasks such as alignment and classification, but also in logistic-oriented tasks such as tomogram binning and particle extraction. Dynamo supports the use of graphical processing units (GPUs), yielding considerable speedup factors both for native Dynamo procedures (such as the numerically intensive subtomogram alignment) and procedures defined by the user through its MATLAB-based GPU library for three-dimensional operations. Cloud-based virtual computing environments supplied with a pre-installed version of Dynamo can be publicly accessed through the Amazon Elastic Compute Cloud (EC2), enabling users to rent GPU computing time on a pay-as-you-go basis, thus avoiding upfront investments in hardware and longterm software maintenance. PMID:28580909
Castaño-Díez, Daniel
2017-06-01
Dynamo is a package for the processing of tomographic data. As a tool for subtomogram averaging, it includes different alignment and classification strategies. Furthermore, its data-management module allows experiments to be organized in groups of tomograms, while offering specialized three-dimensional tomographic browsers that facilitate visualization, location of regions of interest, modelling and particle extraction in complex geometries. Here, a technical description of the package is presented, focusing on its diverse strategies for optimizing computing performance. Dynamo is built upon mbtools (middle layer toolbox), a general-purpose MATLAB library for object-oriented scientific programming specifically developed to underpin Dynamo but usable as an independent tool. Its structure intertwines a flexible MATLAB codebase with precompiled C++ functions that carry the burden of numerically intensive operations. The package can be delivered as a precompiled standalone ready for execution without a MATLAB license. Multicore parallelization on a single node is directly inherited from the high-level parallelization engine provided for MATLAB, automatically imparting a balanced workload among the threads in computationally intense tasks such as alignment and classification, but also in logistic-oriented tasks such as tomogram binning and particle extraction. Dynamo supports the use of graphical processing units (GPUs), yielding considerable speedup factors both for native Dynamo procedures (such as the numerically intensive subtomogram alignment) and procedures defined by the user through its MATLAB-based GPU library for three-dimensional operations. Cloud-based virtual computing environments supplied with a pre-installed version of Dynamo can be publicly accessed through the Amazon Elastic Compute Cloud (EC2), enabling users to rent GPU computing time on a pay-as-you-go basis, thus avoiding upfront investments in hardware and longterm software maintenance.
Colonic polyps: application value of computer-aided detection in computed tomographic colonography.
Zhang, Hui-Mao; Guo, Wei; Liu, Gui-Feng; An, Dong-Hong; Gao, Shuo-Hui; Sun, Li-Bo; Yang, Hai-Shan
2011-02-01
Colonic polyps are frequently encountered in clinics. Computed tomographic colonography (CTC), as a painless and quick detection, has high values in clinics. In this study, we evaluated the application value of computer-aided detection (CAD) in CTC detection of colonic polyps in the Chinese population. CTC was performed with a GE 64-row multidetector computed tomography (MDCT) scanner. Data of 50 CTC patients (39 patients positive for at least one polyp of ≥ 0.5 cm in size and the other 11 patients negative by endoscopic detection) were retrospectively reviewed first without computer-aided detection (CAD) and then with CAD by four radiologists (two were experienced and another two inexperienced) blinded to colonoscopy findings. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of detected colonic polyps, as well as the areas under the ROC curves (Az value) with and without CAD were calculated. CAD increased the overall sensitivity, specificity, positive predictive value, negative predictive value and accuracy of the colonic polyps detected by experienced and inexperienced readers. The sensitivity in detecting small polyps (5 - 9 mm) with CAD in experienced and inexperienced readers increased from 82% and 44% to 93% and 82%, respectively (P > 0.05 and P < 0.001). With the use of CAD, the overall false positive rate and false negative rate for the detection of polyps by experienced and inexperienced readers decreased in different degrees. Among 13 sessile polyps not detected by CAD, two were ≥ 1.0 cm, eleven were 5 - 9 mm in diameter, and nine were flat-shaped lesions. The application of CAD in combination with CTC can increase the ability to detect colonic polyps, particularly for inexperienced readers. However, CAD is of limited value for the detection of flat polyps.
NVIDIA OptiX ray-tracing engine as a new tool for modelling medical imaging systems
NASA Astrophysics Data System (ADS)
Pietrzak, Jakub; Kacperski, Krzysztof; Cieślar, Marek
2015-03-01
The most accurate technique to model the X- and gamma radiation path through a numerically defined object is the Monte Carlo simulation which follows single photons according to their interaction probabilities. A simplified and much faster approach, which just integrates total interaction probabilities along selected paths, is known as ray tracing. Both techniques are used in medical imaging for simulating real imaging systems and as projectors required in iterative tomographic reconstruction algorithms. These approaches are ready for massive parallel implementation e.g. on Graphics Processing Units (GPU), which can greatly accelerate the computation time at a relatively low cost. In this paper we describe the application of the NVIDIA OptiX ray-tracing engine, popular in professional graphics and rendering applications, as a new powerful tool for X- and gamma ray-tracing in medical imaging. It allows the implementation of a variety of physical interactions of rays with pixel-, mesh- or nurbs-based objects, and recording any required quantities, like path integrals, interaction sites, deposited energies, and others. Using the OptiX engine we have implemented a code for rapid Monte Carlo simulations of Single Photon Emission Computed Tomography (SPECT) imaging, as well as the ray-tracing projector, which can be used in reconstruction algorithms. The engine generates efficient, scalable and optimized GPU code, ready to run on multi GPU heterogeneous systems. We have compared the results our simulations with the GATE package. With the OptiX engine the computation time of a Monte Carlo simulation can be reduced from days to minutes.
Which test for CAD should be used in patients with left bundle branch block?
Xu, Bo; Cremer, Paul; Jaber, Wael; Moir, Stuart; Harb, Serge C; Rodriguez, L Leonardo
2018-03-01
Exercise stress electrocardiography is unreliable as a test for obstructive coronary artery disease (CAD) if the patient has left bundle branch block. The authors provide an algorithm for using alternative tests: exercise stress echocardiography, dobutamine echocardiography, computed tomographic (CT) angiography, and nuclear myocardial perfusion imaging. Copyright © 2018 Cleveland Clinic.
High resolution microtomography for density and spatial infomation about wood structures
Barbara Illman; Betsy Dowd
1999-01-01
Microtomography has successfully been used to characterize loss of structural integrity of wood. Tomographic images were generated with the newly developed third generation x-ray computed microtomography (XCMT) instrument at the X27A beamline at the national Synchrotron Light source (NSLS). The beamline is equipped with high-flux x-ray monochromator based on multilayer...
Temerkhanov, F T; Garafutdinov, D M; Arkharov, S L
1997-01-01
The authors analyze the efficacy of repair of atrophied [correction of arthrophic] alveolar processes of the jaws in the projections of the maxillary sinus and inferior alveolar canal with endosseous implants with porous cone-dilating mesostructure made of TN-1P alloy. Prospects for using the new implant design are outlined.
Tomographic Imaging of Water Injection and Withdrawal in PEMFC Gas Diffusion Layers
DOE Office of Scientific and Technical Information (OSTI.GOV)
McGill U; Gostick, J. T.; Gunterman, H. P.
2010-06-25
X-ray computed tomography was used to visualize the water configurations inside gas diffusion layers for various applied capillary pressures, corresponding to both water invasion and withdrawal. A specialized sample holder was developed to allow capillary pressure control on the small-scale samples required. Tests were performed on GDL specimens with and without hydrophobic treatments.
Delayed cerebral development in twins with congenital hyperthyroidism.
Kopelman, A E
1983-09-01
Twins had congenital hyperthyroidism and delayed cerebral development manifested as ventriculomegaly, increased space in the interhemispheric fissure, and an exaggerated gyral pattern on cranial computed tomographic scans. At 3 1/2 years of age, both children had delayed development. Fetal and neonatal hyperthyroidism may interfere with normal brain growth and maturation with both neuranatomic and developmental sequelae.
Dental optical tomography with upconversion nanoparticles—a feasibility study
Long, Feixiao; Intes, Xavier
2017-01-01
Abstract. Upconversion nanoparticles (UCNPs) have the unique ability to emit multiple colors upon excitation by near-infrared (NIR) light. Herein, we investigate the potential use of UCNPs as contrast agents for dental optical tomography, with a focus on monitoring the status of fillings after dental restoration. The potential of performing tomographic imaging using UCNP emission of visible or NIR light is established. This in silico and ex vivo study paves the way toward employing UCNPs as theranostic agents for dental applications. PMID:28586852
1983-02-23
Annihilation Techniques SONIA MIIAN S., R. ZANA , J.CH. ABBE, and G. DUPLATRE - xxviii P-80 Study of Microemulsion Systems by Positron Annihilation...California, Berkeley CA 94720, U.S.A. Primary considerations for the design of positron emission tomographs for medical studies in humans are high...imaging system for medical applications is to produce an image in as short as time as possible which represents as accurately Ias possible the
Commissioning of the J-PET Detector for Studies of Decays of Positronium Atoms
NASA Astrophysics Data System (ADS)
Czerwiński, E.; Dulski, K.; Białas, P.; Curceanu, C.; Gajos, A.; Głowacz, B.; Gorgol, M.; Hiesmayr, B. C.; Jasińska, B.; Kisielewska, D.; Korcyl, G.; Kowalski, P.; Kozik, T.; Krawczyk, N.; Krzemień, W.; Kubicz, E.; Mohammed, M.; Niedźwiecki, Sz.; Pałka, M.; Pawlik-Niedźwiecka, M.; Raczyński, L.; Rudy, Z.; Sharma, N. G.; Sharma, S.; Shopa, R. Y.; Silarski, M.; Skurzok, M.; Wieczorek, A.; Wiślicki, W.; Zgardzińska, B.; Zieliński, M.; Moskal, P.
The Jagiellonian Positron Emission Tomograph (J-PET) is a detector for medical imaging of the whole human body as well as for physics studies involving detection of electron-positron annihilation into photons. J-PET has high angular and time resolution and allows for measurement of spin of the positronium and the momenta and polarization vectors of annihilation quanta. In this article, we present the potential of the J-PET system for background rejection in the decays of positronium atoms.
Dental optical tomography with upconversion nanoparticles—a feasibility study
NASA Astrophysics Data System (ADS)
Long, Feixiao; Intes, Xavier
2017-06-01
Upconversion nanoparticles (UCNPs) have the unique ability to emit multiple colors upon excitation by near-infrared (NIR) light. Herein, we investigate the potential use of UCNPs as contrast agents for dental optical tomography, with a focus on monitoring the status of fillings after dental restoration. The potential of performing tomographic imaging using UCNP emission of visible or NIR light is established. This in silico and ex vivo study paves the way toward employing UCNPs as theranostic agents for dental applications.
Dental optical tomography with upconversion nanoparticles-a feasibility study.
Long, Feixiao; Intes, Xavier
2017-06-01
Upconversion nanoparticles (UCNPs) have the unique ability to emit multiple colors upon excitation by near-infrared (NIR) light. Herein, we investigate the potential use of UCNPs as contrast agents for dental optical tomography, with a focus on monitoring the status of fillings after dental restoration. The potential of performing tomographic imaging using UCNP emission of visible or NIR light is established. This in silico and ex vivo study paves the way toward employing UCNPs as theranostic agents for dental applications.
Gonzalo, Irene T Gaw; Itti, Emmanuel; Mlikotic, Anton; Pham, Le H; Cesar, Romeo B; Meignan, Michel; Mishkin, Fred S
2003-01-01
To evaluate the feasibility of using [(18)F]fluorodeoxyglucose ((18)FDG) triple-head coincidence imaging as a potential cost-effective alternative to positron emission tomography in the setting of suspected recurrence of papillary thyroid carcinoma. We retrospectively studied 10 patients with suspected recurrence of papillary carcinoma of the thyroid, who underwent (18)FDG coincidence imaging,(131)I scanning, and a reference anatomic scan (computed tomography, magnetic resonance imaging, or both) within 1 year in most cases. The (131)I scan detected the recurrence in five patients (62.5%) and failed to reveal recurrent cancer in three patients (37.5%); in contrast,(18)FDG imaging detected the recurrence in eight patients (100%) and was true negative in two patients in whom the scans were performed more than 1 year after effective therapy for the recurrence. The sensitivity of detection was unrelated to lesion size. The (18)FDG imaging results led to additional radiotherapy in all (131)I-negative patients, two of whom had high thyroglobulin levels and one of whom had a low thyroglobulin concentration but the presence of antithy-roglobulin antibodies. We conclude that (18)FDG triple-head coincidence imaging is useful for routine management of patients with thyroid cancer who have no abnormalities detected on (131)I scans but have high serum thyroglobulin levels. This technique, however, may not be as sensitive as a dedicated positron emission tomographic device, particularly for the assessment of small tumors.
Zheleznyak, Alexander; Garbow, Joel R; Neeman, Michal; Lapi, Suzanne E
2015-01-01
The goal of this work was to study the efficacy of the positron emission tomography (PET) tracers 2-deoxy-2-[18F]fluoro-D-glucose ([18F]FDG) and 64Cu-diacetyl-bis(N4-methylthiosemicarbazone) ([64Cu]ATSM) and in monitoring placental and fetal functional response to acute hyperoxia in late-term pregnant mice subjected to experimentally induced chronic hypoxia. E15 mice were maintained at 12% inspired oxygen for 72 hours and then imaged during oxygen inhalation with either [18F]FDG to monitor nutrient transport or 64Cu-ATSM to establish the presence of hypoxia. Computed tomography (CT) with contrast allowed clear visualization of both placentas and fetuses. The average ratio of fetal to placental [18F]FDG uptake was 0.45 ± 0.1 for the hypoxic animals and 0.55 ± 0.1 for the normoxic animals, demonstrating a significant decrease (p = .0002) in placental function in dams exposed to chronic hypoxic conditions. Hypoxic placentas and fetuses retained more 64Cu-ATSM compared to normoxic placentas and fetuses. Herein we report first-in-mouse PET imaging of fetuses employing both tracers [18F]FDG (metabolism) and 64Cu-ATSM (hypoxia). [18F]FDG PET/CT imaging allowed clear visualization of placental-fetal structures and supported quantification of tracer uptake, making this a sensitive tool for monitoring placental function in preclinical rodent models. These measurements illustrate the potentially irreversible damage generated by chronic exposure to hypoxia, which cannot be corrected by acute exposure to hyperoxia.
Box Tomography: An efficient tomographic method for imaging localized structures in the deep Earth
NASA Astrophysics Data System (ADS)
Masson, Yder; Romanowicz, Barbara
2017-04-01
The accurate imaging of localized geological structures inside the deep Earth is key to understand our planet and its history. Since the introduction of the Preliminary Reference Earth Model, many generations of global tomographic models have been developed and give us access to the 3D structure of the Earth's interior. The latest generation of global tomographic models has emerged with the development of accurate numerical wavefield computations in a 3D earth combined with access to enhanced HPC capabilities. These models have sharpened up mantle images and unveiled relatively small scale structures that were blurred out in previous generation models. Fingerlike structures have been found at the base of the oceanic asthenosphere, and vertically oriented broad low velocity plume conduits [1] extend throughout the lower mantle beneath those major hotspots that are located within the perimeter of the deep mantle large low shear velocity provinces (LLSVPs). While providing new insights into our understanding of mantle dynamics, the detailed morphology of these features requires further efforts to obtain higher resolution images. In recent years, we developed a theoretical framework [2][3] for the tomographic imaging of localised geological structures buried inside the Earth, where no seismic sources nor receivers are necessarily present. We call this "box tomography" [4]. The essential difference between box-tomography and standard tomographic methods is that the numerical modeling (i.e. the raytracing in travel time tomography and the wave propagation in waveform tomography or full waveform inversion) is completely confined within the small box-region imaged. Thus, box tomography is a lot more efficient than global tomography (i.e. where we invert for the velocity in the larger volume that encompasses all the sources and receivers), for imaging localised objects. We present 2D and 3D examples showing that box tomography can be employed for imaging structures present within the D'' region at the base of the mantle. Further, we show that box-tomography performs well even in the difficult situation where the velocity distribution in the mantle above the target structure is not known a-priori. REFERENCES [1] French, S. W. and B. Romanowicz (2015) Broad Plumes at the base of the mantle beneath major hotspots, Nature, 525, 95-99 [2] Masson, Y., Cupillard, P., Capdeville, Y., & Romanowicz, B. (2013). On the numerical implementation of time-reversal mirrors for tomographic imaging. Geophysical Journal International, ggt459. [3] Masson, Y., & Romanowicz, B. (2017). Fast computation of synthetic seismograms within a medium containing remote localized perturbations: a numerical solution to the scattering problem. Geophysical Journal International, 208(2), 674-692. [4] Masson, Y., & Romanowicz, B. (2017). Box Tomography: Localised imaging of remote targets buried in an unknown medium, a step forward for understanding key structures in the deep Earth. Geophysical Journal International, (under review).
Hybrid Gama Emission Tomography (HGET): FY16 Annual Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Miller, Erin A.; Smith, Leon E.; Wittman, Richard S.
2017-02-01
Current International Atomic Energy Agency (IAEA) methodologies for the verification of fresh low-enriched uranium (LEU) and mixed oxide (MOX) fuel assemblies are volume-averaging methods that lack sensitivity to individual pins. Further, as fresh fuel assemblies become more and more complex (e.g., heavy gadolinium loading, high degrees of axial and radial variation in fissile concentration), the accuracy of current IAEA instruments degrades and measurement time increases. Particularly in light of the fact that no special tooling is required to remove individual pins from modern fuel assemblies, the IAEA needs new capabilities for the verification of unirradiated (i.e., fresh LEU and MOX)more » assemblies to ensure that fissile material has not been diverted. Passive gamma emission tomography has demonstrated potential to provide pin-level verification of spent fuel, but gamma-ray emission rates from unirradiated fuel emissions are significantly lower, precluding purely passive tomography methods. The work presented here introduces the concept of Hybrid Gamma Emission Tomography (HGET) for verification of unirradiated fuels, in which a neutron source is used to actively interrogate the fuel assembly and the resulting gamma-ray emissions are imaged using tomographic methods to provide pin-level verification of fissile material concentration.« less
X-ray fluorescence tomographic system design and image reconstruction.
Cong, Wenxiang; Shen, Haiou; Cao, Guohua; Liu, Hong; Wang, Ge
2013-01-01
In this paper, we presented a new design of x-ray fluorescence CT imaging system. For detecting fuorescence signals of gold nanoparticles in-vivo, multiple spectroscopic detectors are arranged and rotated orthogonal to an excited region of interest so that a localized scan can be acquired with a maximized efficiency. Excitation filtration was employed to minimize the effects of low-energy x-rays and background scattering for lowering radiation dose to the object. Numerical simulations showed that the radiation dose is less than 300 mGy/second for a complete 30 views tomographic scan; and the sensitivity of 3D fluorescence signal detection is up to 0.2% contrast concentrations of nanoparticles. The x-ray fluorescence computed tomography is an important molecular imaging tool. It can be used directly in samall animal research. It has great translational potential for future clinical applications.
Partially coherent lensfree tomographic microscopy⋄
Isikman, Serhan O.; Bishara, Waheb; Ozcan, Aydogan
2012-01-01
Optical sectioning of biological specimens provides detailed volumetric information regarding their internal structure. To provide a complementary approach to existing three-dimensional (3D) microscopy modalities, we have recently demonstrated lensfree optical tomography that offers high-throughput imaging within a compact and simple platform. In this approach, in-line holograms of objects at different angles of partially coherent illumination are recorded using a digital sensor-array, which enables computing pixel super-resolved tomographic images of the specimen. This imaging modality, which forms the focus of this review, offers micrometer-scale 3D resolution over large imaging volumes of, for example, 10–15 mm3, and can be assembled in light weight and compact architectures. Therefore, lensfree optical tomography might be particularly useful for lab-on-a-chip applications as well as for microscopy needs in resource-limited settings. PMID:22193016
System for tomographic determination of the power distribution in electron beams
Elmer, John W.; Teruya, Alan T.; O'Brien, Dennis W.
1995-01-01
A tomographic technique for measuring the current density distribution in electron beams using electron beam profile data acquired from a modified Faraday cup to create an image of the current density in high and low power beams. The modified Faraday cup includes a narrow slit and is rotated by a stepper motor and can be moved in the x, y and z directions. The beam is swept across the slit perpendicular thereto and controlled by deflection coils, and the slit rotated such that waveforms are taken every few degrees form 0.degree. to 360.degree. and the waveforms are recorded by a digitizing storage oscilloscope. Two-dimensional and three-dimensional images of the current density distribution in the beam can be reconstructed by computer tomography from this information, providing quantitative information about the beam focus and alignment.
System for tomographic determination of the power distribution in electron beams
Elmer, J.W.; Teruya, A.T.; O`Brien, D.W.
1995-11-21
A tomographic technique for measuring the current density distribution in electron beams using electron beam profile data acquired from a modified Faraday cup to create an image of the current density in high and low power beams. The modified Faraday cup includes a narrow slit and is rotated by a stepper motor and can be moved in the x, y and z directions. The beam is swept across the slit perpendicular thereto and controlled by deflection coils, and the slit rotated such that waveforms are taken every few degrees form 0{degree} to 360{degree} and the waveforms are recorded by a digitizing storage oscilloscope. Two-dimensional and three-dimensional images of the current density distribution in the beam can be reconstructed by computer tomography from this information, providing quantitative information about the beam focus and alignment. 12 figs.
Active and Passive Hydrologic Tomographic Surveys:A Revolution in Hydrology (Invited)
NASA Astrophysics Data System (ADS)
Yeh, T. J.
2013-12-01
Mathematical forward or inverse problems of flow through geological media always have unique solutions if necessary conditions are givens. Unique mathematical solutions to forward or inverse modeling of field problems are however always uncertain (an infinite number of possibilities) due to many reasons. They include non-representativeness of the governing equations, inaccurate necessary conditions, multi-scale heterogeneity, scale discrepancies between observation and model, noise and others. Conditional stochastic approaches, which derives the unbiased solution and quantifies the solution uncertainty, are therefore most appropriate for forward and inverse modeling of hydrological processes. Conditioning using non-redundant data sets reduces uncertainty. In this presentation, we explain non-redundant data sets in cross-hole aquifer tests, and demonstrate that active hydraulic tomographic survey (using man-made excitations) is a cost-effective approach to collect the same type but non-redundant data sets for reducing uncertainty in the inverse modeling. We subsequently show that including flux measurements (a piece of non-redundant data set) collected in the same well setup as in hydraulic tomography improves the estimated hydraulic conductivity field. We finally conclude with examples and propositions regarding how to collect and analyze data intelligently by exploiting natural recurrent events (river stage fluctuations, earthquakes, lightning, etc.) as energy sources for basin-scale passive tomographic surveys. The development of information fusion technologies that integrate traditional point measurements and active/passive hydrogeophysical tomographic surveys, as well as advances in sensor, computing, and information technologies may ultimately advance our capability of characterizing groundwater basins to achieve resolution far beyond the feat of current science and technology.
Wavefield simulations of earthquakes in Alaska for tomographic inversion
NASA Astrophysics Data System (ADS)
Silwal, V.; Tape, C.; Casarotti, E.
2017-12-01
We assemble a catalog of moment tensors and a three-dimensional seismic velocity model for mainland Alaska, in preparation for an iterative tomographic inversion using spectral-element and adjoint methods. The catalog contains approximately 200 earthquakes with Mw ≥ 4.0 that generate good long-period (≥6 s) signals for stations at distances up to approximately 500 km. To maximize the fraction of usable stations per earthquake, we divide our model into three subregions for simulations: south-central Alaska, central Alaska, and eastern Alaska. The primary geometrical interfaces in the model are the Moho surface, the basement surface of major sedimentary basins, and the topographic surface. The crustal and upper mantle tomographic model is from Eberhart-Phillips et al. (2006), but modified by removing the uppermost slow layer, then embedding sedimentary basin models for Cook Inlet basin, Susitna basin, and Nenana basin. We compute 3D synthetic seismograms using the spectral-element method. We demonstrate the accuracy of the initial three-dimensional reference model in each subregion by comparing 3D synthetics with observed data for several earthquakes originating in the crust and underlying subducting slab. Full waveform similarity between data and synthetics over the period range 6 s to 30 s provides a basis for an iterative inversion. The target resolution of the crustal structure is 4 km vertically and 20 km laterally. We use surface wave and body wave measurements from local earthquakes to obtain moment tensors that will be used within our tomographic inversion. Local slab events down to 180 km depth, in additional to pervasive crustal seismicity, should enhance resolution.
Xu, Lijun; Liu, Chang; Jing, Wenyang; Cao, Zhang; Xue, Xin; Lin, Yuzhen
2016-01-01
To monitor two-dimensional (2D) distributions of temperature and H2O mole fraction, an on-line tomography system based on tunable diode laser absorption spectroscopy (TDLAS) was developed. To the best of the authors' knowledge, this is the first report on a multi-view TDLAS-based system for simultaneous tomographic visualization of temperature and H2O mole fraction in real time. The system consists of two distributed feedback (DFB) laser diodes, a tomographic sensor, electronic circuits, and a computer. The central frequencies of the two DFB laser diodes are at 7444.36 cm(-1) (1343.3 nm) and 7185.6 cm(-1) (1391.67 nm), respectively. The tomographic sensor is used to generate fan-beam illumination from five views and to produce 60 ray measurements. The electronic circuits not only provide stable temperature and precise current controlling signals for the laser diodes but also can accurately sample the transmitted laser intensities and extract integrated absorbances in real time. Finally, the integrated absorbances are transferred to the computer, in which the 2D distributions of temperature and H2O mole fraction are reconstructed by using a modified Landweber algorithm. In the experiments, the TDLAS-based tomography system was validated by using asymmetric premixed flames with fixed and time-varying equivalent ratios, respectively. The results demonstrate that the system is able to reconstruct the profiles of the 2D distributions of temperature and H2O mole fraction of the flame and effectively capture the dynamics of the combustion process, which exhibits good potential for flame monitoring and on-line combustion diagnosis.
NASA Astrophysics Data System (ADS)
Xu, Lijun; Liu, Chang; Jing, Wenyang; Cao, Zhang; Xue, Xin; Lin, Yuzhen
2016-01-01
To monitor two-dimensional (2D) distributions of temperature and H2O mole fraction, an on-line tomography system based on tunable diode laser absorption spectroscopy (TDLAS) was developed. To the best of the authors' knowledge, this is the first report on a multi-view TDLAS-based system for simultaneous tomographic visualization of temperature and H2O mole fraction in real time. The system consists of two distributed feedback (DFB) laser diodes, a tomographic sensor, electronic circuits, and a computer. The central frequencies of the two DFB laser diodes are at 7444.36 cm-1 (1343.3 nm) and 7185.6 cm-1 (1391.67 nm), respectively. The tomographic sensor is used to generate fan-beam illumination from five views and to produce 60 ray measurements. The electronic circuits not only provide stable temperature and precise current controlling signals for the laser diodes but also can accurately sample the transmitted laser intensities and extract integrated absorbances in real time. Finally, the integrated absorbances are transferred to the computer, in which the 2D distributions of temperature and H2O mole fraction are reconstructed by using a modified Landweber algorithm. In the experiments, the TDLAS-based tomography system was validated by using asymmetric premixed flames with fixed and time-varying equivalent ratios, respectively. The results demonstrate that the system is able to reconstruct the profiles of the 2D distributions of temperature and H2O mole fraction of the flame and effectively capture the dynamics of the combustion process, which exhibits good potential for flame monitoring and on-line combustion diagnosis.
On the estimation of wall pressure coherence using time-resolved tomographic PIV
NASA Astrophysics Data System (ADS)
Pröbsting, Stefan; Scarano, Fulvio; Bernardini, Matteo; Pirozzoli, Sergio
2013-07-01
Three-dimensional time-resolved velocity field measurements are obtained using a high-speed tomographic Particle Image Velocimetry (PIV) system on a fully developed flat plate turbulent boundary layer for the estimation of wall pressure fluctuations. The work focuses on the applicability of tomographic PIV to compute the coherence of pressure fluctuations, with attention to the estimation of the stream and spanwise coherence length. The latter is required for estimations of aeroacoustic noise radiation by boundary layers and trailing edge flows, but is also of interest for vibro-structural problems. The pressure field is obtained by solving the Poisson equation for incompressible flows, where the source terms are provided by time-resolved velocity field measurements. Measured 3D velocity data is compared to results obtained from planar PIV, and a Direct Numerical Simulation (DNS) at similar Reynolds number. An improved method for the estimation of the material based on a least squares estimator of the velocity derivative along a particle trajectory is proposed and applied. Computed surface pressure fluctuations are further verified by means of simultaneous measurements by a pinhole microphone and compared to the DNS results and a semi-empirical model available from literature. The correlation coefficient for the reconstructed pressure time series with respect to pinhole microphone measurements attains approximately 0.5 for the band-pass filtered signal over the range of frequencies resolved by the velocity field measurements. Scaled power spectra of the pressure at a single point compare favorably to the DNS results and those available from literature. Finally, the coherence of surface pressure fluctuations and the resulting span- and streamwise coherence lengths are estimated and compared to semi-empirical models and DNS results.
Finite frequency shear wave splitting tomography: a model space search approach
NASA Astrophysics Data System (ADS)
Mondal, P.; Long, M. D.
2017-12-01
Observations of seismic anisotropy provide key constraints on past and present mantle deformation. A common method for upper mantle anisotropy is to measure shear wave splitting parameters (delay time and fast direction). However, the interpretation is not straightforward, because splitting measurements represent an integration of structure along the ray path. A tomographic approach that allows for localization of anisotropy is desirable; however, tomographic inversion for anisotropic structure is a daunting task, since 21 parameters are needed to describe general anisotropy. Such a large parameter space does not allow a straightforward application of tomographic inversion. Building on previous work on finite frequency shear wave splitting tomography, this study aims to develop a framework for SKS splitting tomography with a new parameterization of anisotropy and a model space search approach. We reparameterize the full elastic tensor, reducing the number of parameters to three (a measure of strength based on symmetry considerations for olivine, plus the dip and azimuth of the fast symmetry axis). We compute Born-approximation finite frequency sensitivity kernels relating model perturbations to splitting intensity observations. The strong dependence of the sensitivity kernels on the starting anisotropic model, and thus the strong non-linearity of the inverse problem, makes a linearized inversion infeasible. Therefore, we implement a Markov Chain Monte Carlo technique in the inversion procedure. We have performed tests with synthetic data sets to evaluate computational costs and infer the resolving power of our algorithm for synthetic models with multiple anisotropic layers. Our technique can resolve anisotropic parameters on length scales of ˜50 km for realistic station and event configurations for dense broadband experiments. We are proceeding towards applications to real data sets, with an initial focus on the High Lava Plains of Oregon.
Bilateral choroidal osteomas associated with fatal systemic illness.
Kline, L B; Skalka, H W; Davidson, J D; Wilmes, F J
1982-02-01
An 11-year-old black boy complained of intermittent occipital headaches with nausea and projectile vomiting. Previous skin and lung biopsy specimens were interpreted as histiocytosis X. Cranial computed tomographic scanning disclosed a mass lesion in the region of the choroid plexus of the left lateral ventricle. This was surgically removed but proved nondiagnostic despite extensive histologic examination. An ophthalmologic evaluation showed discrete, elevated, yellow-white choroidal tumors in both maculas. The ophthalmoscopic appearance, as well as ultrasonography and computed tomography, led to the diagnosis of choroidal osteomas.
Kobayashi, Keisuke; Saeki, Yusuke; Kitazawa, Shinsuke; Kobayashi, Naohiro; Kikuchi, Shinji; Goto, Yukinobu; Sakai, Mitsuaki; Sato, Yukio
2017-11-01
It is important to accurately predict the patient's postoperative pulmonary function. The aim of this study was to compare the accuracy of predictions of the postoperative residual pulmonary function obtained with three-dimensional computed tomographic (3D-CT) volumetry with that of predictions obtained with the conventional segment-counting method. Fifty-three patients scheduled to undergo lung cancer resection, pulmonary function tests, and computed tomography were enrolled in this study. The postoperative residual pulmonary function was predicted based on the segment-counting and 3D-CT volumetry methods. The predicted postoperative values were compared with the results of postoperative pulmonary function tests. Regarding the linear correlation coefficients between the predicted postoperative values and the measured values, those obtained using the 3D-CT volumetry method tended to be higher than those acquired using the segment-counting method. In addition, the variations between the predicted and measured values were smaller with the 3D-CT volumetry method than with the segment-counting method. These results were more obvious in COPD patients than in non-COPD patients. Our findings suggested that the 3D-CT volumetry was able to predict the residual pulmonary function more accurately than the segment-counting method, especially in patients with COPD. This method might lead to the selection of appropriate candidates for surgery among patients with a marginal pulmonary function.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zilkha, A.
Computed tomographic (CT) findings in four patients with isolated blow-out fracture of the medial orbital wall are reported. CT delineated the fracture site and its extent in each case, and clearly demonstrated medial rectus muscle entrapment in two. This was confirmed by surgery. CT was found superior to polytomography and proved to be the best radiologic means for the diagnosis of medial orbital wall fracture and muscle entrapment.
High Energy Computed Tomographic Inspection of Munitions
2016-11-01
this collection of information is estimated to av erage 1 hour per response, including the time for rev iewing instructions, searching existing data... estimate or any other aspect of this collection of information, including suggestions for reducing the burden to Department of Defense, Washington...UNCLASSIFIED i CONTENTS Page System Background 1 Unique Features 3 Scattering Estimating Device 3 Distortion and Geometric Calibration
Primitive neuroectodermal tumour of the kidney: radiologic-pathological correlations.
Chea, Y W; Agrawal, Rashi; Poh, Angeline C C
2008-06-01
A primitive neuroectodermal tumour of the kidney is a rare malignancy. We report the computed tomographic features and the histopathological correlation of such a tumour occurring in a middle-aged man. Although the radiological appearance has significant overlap with other renal tumours, this tumour should be included in the differential diagnosis of a large renal mass in younger patients.
Pseudo tumors of the lung after lung volume reduction surgery.
Oey, Inger F; Jeyapalan, Kanagaratnam; Entwisle, James J; Waller, David A
2004-03-01
We describe 2 patients who underwent lung volume reduction surgery, who postoperatively had computed tomographic scans that showed symptomatic mass lesions suggestive of malignancy and an inhaled foreign body. Investigations excluded these conditions with the remaining likely diagnosis of pseudotumor secondary to buttressing material. These potential sequelae of lung volume reduction surgery should be recognized in follow-up investigations.
High-Resolution CT and Angiographic Evaluation of NexStent Wall Adaptation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nemes, Balazs, E-mail: nembal@freemail.hu; Lukacs, Levente; Balazs, Gyoergy
2009-05-15
Carotid stenting is a minimally invasive treatment for extracranial carotid artery stenosis. Stent design may affect technical success and complications in a certain subgroup of patients. We examined the wall adaptability of a new closed-cell carotid stent (NexStent), which has a unique rolled sheet design. Forty-one patients had 42 carotid arteries treated with angioplasty and stenting for internal carotid artery stenosis. The mean patient age was 65 {+-} 10 years. All patients underwent high-resolution computed tomographic angiography after the stent implantation. Data analysis included pre- and postprocedural stenosis, procedure complications, plaque calcification, and stent apposition. We reviewed the angiographic andmore » computed tomographic images for plaque coverage and stent expansion. All procedures were technically successful. Mean stenosis was reduced from 84 {+-} 8% before the procedure to 15.7 {+-} 7% after stenting. Two patients experienced transient ischemic attack; one patient had bradycardia and hypotension. Stent induced kinking was observed in one case. Good plaque coverage and proper overlapping of the rolled sheet was achieved in all cases. There was weak correlation between the residual stenosis and the amount of calcification. The stent provides adequate expansion and adaptation to the tapering anatomy of the bifurcation.« less
Volume reconstruction optimization for tomo-PIV algorithms applied to experimental data
NASA Astrophysics Data System (ADS)
Martins, Fabio J. W. A.; Foucaut, Jean-Marc; Thomas, Lionel; Azevedo, Luis F. A.; Stanislas, Michel
2015-08-01
Tomographic PIV is a three-component volumetric velocity measurement technique based on the tomographic reconstruction of a particle distribution imaged by multiple camera views. In essence, the performance and accuracy of this technique is highly dependent on the parametric adjustment and the reconstruction algorithm used. Although synthetic data have been widely employed to optimize experiments, the resulting reconstructed volumes might not have optimal quality. The purpose of the present study is to offer quality indicators that can be applied to data samples in order to improve the quality of velocity results obtained by the tomo-PIV technique. The methodology proposed can potentially lead to significantly reduction in the time required to optimize a tomo-PIV reconstruction, also leading to better quality velocity results. Tomo-PIV data provided by a six-camera turbulent boundary-layer experiment were used to optimize the reconstruction algorithms according to this methodology. Velocity statistics measurements obtained by optimized BIMART, SMART and MART algorithms were compared with hot-wire anemometer data and velocity measurement uncertainties were computed. Results indicated that BIMART and SMART algorithms produced reconstructed volumes with equivalent quality as the standard MART with the benefit of reduced computational time.
Pulp Revascularization on Permanent Teeth with Open Apices in a Middle-aged Patient.
Wang, Yu; Zhu, Xiaofei; Zhang, Chengfei
2015-09-01
Pulp revascularization is a promising procedure for the treatment of adolescents' immature permanent teeth with necrotic pulp and/or apical periodontitis. However, the ability to successfully perform pulp revascularization in a middle-aged patient remains unclear. A 39-year-old woman was referred for treatment of teeth #20 and #29 with necrotic pulp, extensive periapical radiolucencies, and incomplete apices. Pulp revascularization procedures were attempted, including root canal debridement, triple antibiotic paste medication, and platelet-rich plasma transplantation to act as a scaffold. Periapical radiographic and cone-beam computed tomographic examinations were used to review the changes in the apical lesions and root apex configuration. The patient remained asymptomatic throughout the 30-month follow-up. Periapical radiographic examination revealed no change in the apical lesions of either tooth at 8 months. The periapical radiolucency disappeared on tooth #20 and significantly decreased on tooth #29 by the 30-month follow-up, findings that were also confirmed by cone-beam computed tomographic imaging. No evidence of root lengthening or thickening was observed. Successful revascularization was achieved in a middle-aged patient's teeth. Copyright © 2015 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Marion, D W; Bouma, G J
1991-12-01
Previous studies using the xenon-133 cerebral blood flow (CBF) method have documented the impairment of CO2 vasoresponsivity after a severe head injury, but only global values can be obtained reliably with this technique. We studied CO2 vasoresponsivity using the stable xenon-enhanced computed tomographic CBF method, which provided information about well-defined cortical regions and deep brain structures not available with the xenon-133 method. In 17 patients with admission Glasgow Coma Scale scores of 8 or less, hemispheric CO2 vasoresponsivity ranged from 1.3 to 8.5% per mm Hg change in partial CO2 pressure. Lobar, cerebellar, basal ganglia, and brain stem CO2 vasoresponsivity frequently varied from the mean global value by more than 25%. In all but one patient, local CO2 vasoresponsivity in one or more of these areas differed from the mean global value by more than 50%. The greatest variability occurred in patients with acute subdural hematomas and diffuse (bihemispheric) injuries. This variability in CO2 vasoresponsivity has important implications for the effective and safe management of intracranial hypertension that frequently accompanies severe head injury.
Coe, Ryan L; Seibel, Eric J
2012-12-01
We present a method for modeling image formation in optical projection tomographic microscopy (OPTM) using high numerical aperture (NA) condensers and objectives. Similar to techniques used in computed tomography, OPTM produces three-dimensional, reconstructed images of single cells from two-dimensional projections. The model is capable of simulating axial scanning of a microscope objective to produce projections, which are reconstructed using filtered backprojection. Simulation of optical scattering in transmission optical microscopy is designed to analyze all aspects of OPTM image formation, such as degree of specimen staining, refractive-index matching, and objective scanning. In this preliminary work, a set of simulations is performed to examine the effect of changing the condenser NA, objective scan range, and complex refractive index on the final reconstruction of a microshell with an outer radius of 1.5 μm and an inner radius of 0.9 μm. The model lays the groundwork for optimizing OPTM imaging parameters and triaging efforts to further improve the overall system design. As the model is expanded in the future, it will be used to simulate a more realistic cell, which could lead to even greater impact.
Rozen, Warren M; Chubb, Daniel; Ashton, Mark W; Webster, Howard R
2012-05-01
The use of advanced imaging technologies such as computed tomographic angiography (CTA) has opened the door to the analysis of microvascular anatomy not previously demonstrable with prior imaging techniques. While CTA has been used to evaluate the vascular anatomy of donor body regions in the planning of harvest of tissue for free flap transfer, the use of CTA to evaluate tissues after tissue transplantation has not been demonstrated. The current study aimed to explore whether vascular anatomy was able to highlight CTA within transferred flaps. The arterial and venous anatomy of a transferred deep inferior epigastric artery (DIEA) perforator (DIEP) flap was explored postoperatively with the use of CTA. Intra-flap vasculature was mapped and recorded qualitatively. Postoperative CTA is able to highlight the vascular pedicle of a transferred free flap, highlight the course of individual perforators supplying the flap, and map the zones of lesser perfusion by the source pedicle. The current study has demonstrated that CTA may be of value in identifying vascular anatomy within transferred tissue, as a guide to evaluate flap perfusion and planning further surgery involving the flap. © Springer-Verlag 2011
Navigation-supported diagnosis of the substantia nigra by matching midbrain sonography and MRI
NASA Astrophysics Data System (ADS)
Salah, Zein; Weise, David; Preim, Bernhard; Classen, Joseph; Rose, Georg
2012-03-01
Transcranial sonography (TCS) is a well-established neuroimaging technique that allows for visualizing several brainstem structures, including the substantia nigra, and helps for the diagnosis and differential diagnosis of various movement disorders, especially in Parkinsonian syndromes. However, proximate brainstem anatomy can hardly be recognized due to the limited image quality of B-scans. In this paper, a visualization system for the diagnosis of the substantia nigra is presented, which utilizes neuronavigated TCS to reconstruct tomographical slices from registered MRI datasets and visualizes them simultaneously with corresponding TCS planes in realtime. To generate MRI tomographical slices, the tracking data of the calibrated ultrasound probe are passed to an optimized slicing algorithm, which computes cross sections at arbitrary positions and orientations from the registered MRI dataset. The extracted MRI cross sections are finally fused with the region of interest from the ultrasound image. The system allows for the computation and visualization of slices at a near real-time rate. Primary tests of the system show an added value to the pure sonographic imaging. The system also allows for reconstructing volumetric (3D) ultrasonic data of the region of interest, and thus contributes to enhancing the diagnostic yield of midbrain sonography.
Lew, Henry L; Lee, Eun Ha; Miyoshi, Yasushi; Chang, Douglas G; Date, Elaine S; Jerger, James F
2004-03-01
Because of the violent nature of traumatic brain injury, traumatic brain injury patients are susceptible to various types of trauma involving the auditory system. We report a case of a 55-yr-old man who presented with communication problems after traumatic brain injury. Initial results from behavioral audiometry and Weber/Rinne tests were not reliable because of poor cooperation. He was transferred to our service for inpatient rehabilitation, where review of the initial head computed tomographic scan showed only left temporal bone fracture. Brainstem auditory-evoked potential was then performed to evaluate his hearing function. The results showed bilateral absence of auditory-evoked responses, which strongly suggested bilateral deafness. This finding led to a follow-up computed tomographic scan, with focus on bilateral temporal bones. A subtle transverse fracture of the right temporal bone was then detected, in addition to the left temporal bone fracture previously identified. Like children with hearing impairment, traumatic brain injury patients may not be able to verbalize their auditory deficits in a timely manner. If hearing loss is suspected in a patient who is unable to participate in traditional behavioral audiometric testing, brainstem auditory-evoked potential may be an option for evaluating hearing dysfunction.
Computed tomography in the evaluation of Crohn disease
DOE Office of Scientific and Technical Information (OSTI.GOV)
Goldberg, H.I.; Gore, R.M.; Margulis, A.R.
1983-02-01
The abdominal and pelvic computed tomographic examinations in 28 patients with Crohn disease were analyzed and correlated with conventional barium studies, sinograms, and surgical findings. Mucosal abnormalities such as aphthous lesions, pseudopolyps, and ulcerations were only imaged by conventional techniques. Computed tomography proved superior in demonstrating the mural, serosal, and mesenteric abnormalities such as bowel wall thickening (82%), fibrofatty proliferation of mesenteric fat (39%), mesenteric abscess (25%), inflammatory reaction of the mesentery (14%), and mesenteric lymphadenopathy (18%). Computed tomography was most useful clinically in defining the nature of mass effects, separation, or displacement of small bowel segments seen on smallmore » bowel series. Although conventional barium studies remain the initial diagnostic procedure in evaluating Crohn disease, computed tomography can be a useful adjunct in resolving difficult clinical and radiologic diagnostic problems.« less
Naeser, M A; Baker, E H; Palumbo, C L; Nicholas, M; Alexander, M P; Samaraweera, R; Prete, M N; Hodge, S M; Weissman, T
1998-11-01
To test whether lesion site patterns in patients with chronic, severe aphasia who have no meaningful spontaneous speech are predictive of outcome following treatment with a nonverbal, icon-based computer-assisted visual communication (C-ViC) program. Retrospective study in which computed tomographic scans performed 3 months after onset of stroke and aphasia test scores obtained before C-ViC therapy were reviewed for patients after receiving C-ViC treatment. A neurology department and speech pathology service of a Department of Veterans Affairs medical center and a university aphasia research center. Seventeen patients with stroke and severe aphasia who began treatment with C-ViC from 3 months to 10 years after onset of stroke. Level of ability to use C-ViC on a personal computer to communicate. All patients with bilateral lesions failed to learn C-ViC. For patients with unilateral left hemisphere lesion sites, statistical analyses accurately discriminated between those who could initiate communication with C-ViC from those who were only able to answer directed questions. The critical lesion areas involved temporal lobe structures (Wernicke cortical area and the subcortical temporal isthmus), supraventricular frontal lobe structures (supplementary motor area or cingulate gyrus 24), and the subcortical medial subcallosal fasciculus, deep to the Broca area. Specific lesion sites were also identified for appropriate candidacy for C-ViC. Lesion site patterns on computed tomographic scans are helpful to define candidacy for C-ViC training, and to predict outcome level. A practical method is presented for clinical application of these lesion site results in combination with aphasia test scores.
Soussan, Michael; Cyrta, Joanna; Pouliquen, Christelle; Chouahnia, Kader; Orlhac, Fanny; Martinod, Emmanuel; Eder, Véronique; Morère, Jean-François; Buvat, Irène
2014-09-01
To study whether volume-based indices of fluorine 18 fluorodeoxyglucose positron emission tomographic (PET)/computed tomographic (CT) imaging is an accurate tool to predict the amount of residual viable tumor after induction chemotherapy in patients with locally advanced non-small cell lung cancer (NSCLC). This study was approved by institutional review board with waivers of informed consent. Twenty-two patients with locally advanced NSCLC underwent surgery after induction chemotherapy. All had pre- and posttreatment FDG PET/CT scans. CT largest diameter, CT volume, maximum standardized uptake value (SUVmax), mean SUV (SUVmean), metabolic tumor volume (TV), and total lesion glycolysis of primary tumor were calculated. Changes in tumor measurements were determined by dividing follow-up by baseline measurement (ratio index). Amounts of residual viable tumor, necrosis, fibrous tissue, inflammatory infiltrate, and Ki-67 proliferative index were estimated on resected tumor. Correlations between imaging indices and histologic parameters were estimated by using Spearman correlation coefficients or Mann-Whitney tests. No baseline or posttreatment indices correlated with percentage of residual viable tumor. TV ratio was the only index that correlated with percentage of residual viable tumor (r = 0.61 [95% confidence interval: 0.24, 0.81]; P = .003). Conversely, SUVmax and SUVmean ratios were only indices correlated with Ki-67 (r = 0.62 [95% confidence interval: 0.24, 0.82]; P = .003; and r = 0.60 [95% confidence interval: 0.21, 0.81]; P = .004, respectively). Total lesion glycolysis ratio was moderately correlated with residual viable tumor (r = 0.53 [95% confidence interval: 0.13, 0.78]; P = .01) and with Ki-67 (r = 0.57 [95% confidence interval: 0.18, 0.80]; P = .006). No ratios were correlated with presence of inflammatory infiltrate or foamy macrophages. TV and total lesion glycolysis ratios were the only indices correlated with residual viable tumor after induction chemotherapy in locally advanced NSCLC.
A cylindrical SPECT camera with de-centralized readout scheme
NASA Astrophysics Data System (ADS)
Habte, F.; Stenström, P.; Rillbert, A.; Bousselham, A.; Bohm, C.; Larsson, S. A.
2001-09-01
An optimized brain single photon emission computed tomograph (SPECT) camera is being designed at Stockholm University and Karolinska Hospital. The design goal is to achieve high sensitivity, high-count rate and high spatial resolution. The sensitivity is achieved by using a cylindrical crystal, which gives a closed geometry with large solid angles. A de-centralized readout scheme where only a local environment around the light excitation is readout supports high-count rates. The high resolution is achieved by using an optimized crystal configuration. A 12 mm crystal plus 12 mm light guide combination gave an intrinsic spatial resolution better than 3.5 mm (140 keV) in a prototype system. Simulations show that a modified configuration can improve this value. A cylindrical configuration with a rotating collimator significantly simplifies the mechanical design of the gantry. The data acquisition and control system uses early digitization and subsequent digital signal processing to extract timing and amplitude information, and monitors the position of the collimator. The readout system consists of 12 or more modules each based on programmable logic and a digital signal processor. The modules send data to a PC file server-reconstruction engine via a Firewire (IEEE-1394) network.
A solitary mixed squamous cell and glandular papilloma of the lung.
Kozu, Yoshiki; Maniwa, Tomohiro; Ohde, Yasuhisa; Nakajima, Takashi
2014-01-01
Mixed squamous cell and glandular papilloma (mixed papilloma) of the lung is exceedingly rare, with only 18 cases reported in the literature. Herein, we report a case of mixed papilloma and its associated immunohistochemical and positron emission tomographic (PET) findings. A 60-year-old Japanese male with a smoking history of 40 pack-years presented with a smooth-edged pulmonary lesion in the right S5 segment on computed tomography (CT). F18-fluorodeoxyglucose (FDG) PET revealed abnormally increased FDG uptake in the mass (maximum standardized uptake value, 3.4). We performed right middle lobectomy and combined partial resection of the S8 segment. The 1.8-cm tumor that filled the enlarged lumen of the B5b was histologically diagnosed as mixed papilloma. Immunohistochemically, the pseudostratified columnar epithelium was positive for cytokeratin (CK) 5/6 and CK7. p40 positivity was predominant in the basal and squamous cells. Thyroid transcription factor-1 and carcinoembryonic antigen were negative on immunostaining. Malignant features were absent. The postoperative course has been uneventful for 3 months after the surgery. No recurrences were reported after the surgical resection of the mixed papilloma. Therefore, surgical resection may be considered the mainstay of curative treatment.
NASA Astrophysics Data System (ADS)
Nazifah, A.; Norhanna, S.; Shah, S. I.; Zakaria, A.
2014-11-01
This study aimed to investigate the effects of material filter technique on Tc-99m spectra and performance parameters of Philip ADAC forte dual head gamma camera. Thickness of material filter was selected on the basis of percentage attenuation of various gamma ray energies by different thicknesses of zinc material. A cylindrical source tank of NEMA single photon emission computed tomography (SPECT) Triple Line Source Phantom filled with water and Tc-99m radionuclide injected was used for spectra, uniformity and sensitivity measurements. Vinyl plastic tube was used as a line source for spatial resolution. Images for uniformity were reconstructed by filtered back projection method. Butterworth filter of order 5 and cut off frequency 0.35 cycles/cm was selected. Chang's attenuation correction method was applied by selecting 0.13/cm linear attenuation coefficient. Count rate was decreased with material filter from the compton region of Tc-99m energy spectrum, also from the photopeak region. Spatial resolution was improved. However, uniformity of tomographic image was equivocal, and system volume sensitivity was reduced by material filter. Material filter improved system's spatial resolution. Therefore, the technique may be used for phantom studies to improve the image quality.
New imaging systems in nuclear medicine. Final report, January 1, 1993--December 31, 1995
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1995-12-31
The aim of this program has been to improve the performance of positron emission tomography (PET) to achieve high resolution with high sensitivity. Towards this aim, the authors have carried out the following studies: (1) explored new techniques for detection of annihilation radiation including new detector materials and system geometries, specific areas that they have studied include--exploration of factors related to resolution and sensitivity of PET instrumentation including geometry, detection materials and coding, and the exploration of technique to improve the image quality by use of depth of interaction and increased sampling; (2) complete much of the final testing ofmore » PCR-II, an analog-coded cylindrical positron tomograph, developed and constructed during the current funding period; (3) developed the design of a positron microtomograph with mm resolution for quantitative studies in small animals, a single slice version of this device has been designed and studied by use of computer simulation; (4) continued and expanded the program of biological studies in animal models. Current studies have included imaging of animal models of Parkinson`s and Huntington`s disease and cancer. These studies have included new radiopharmaceuticals and techniques involving molecular biology.« less
The history of MR imaging as seen through the pages of radiology.
Edelman, Robert R
2014-11-01
The first reports in Radiology pertaining to magnetic resonance (MR) imaging were published in 1980, 7 years after Paul Lauterbur pioneered the first MR images and 9 years after the first human computed tomographic images were obtained. Historical advances in the research and clinical applications of MR imaging very much parallel the remarkable advances in MR imaging technology. These advances can be roughly classified into hardware (eg, magnets, gradients, radiofrequency [RF] coils, RF transmitter and receiver, MR imaging-compatible biopsy devices) and imaging techniques (eg, pulse sequences, parallel imaging, and so forth). Image quality has been dramatically improved with the introduction of high-field-strength superconducting magnets, digital RF systems, and phased-array coils. Hybrid systems, such as MR/positron emission tomography (PET), combine the superb anatomic and functional imaging capabilities of MR imaging with the unsurpassed capability of PET to demonstrate tissue metabolism. Supported by the improvements in hardware, advances in pulse sequence design and image reconstruction techniques have spurred dramatic improvements in imaging speed and the capability for studying tissue function. In this historical review, the history of MR imaging technology and developing research and clinical applications, as seen through the pages of Radiology, will be considered.
Simulation of Medical Imaging Systems: Emission and Transmission Tomography
NASA Astrophysics Data System (ADS)
Harrison, Robert L.
Simulation is an important tool in medical imaging research. In patient scans the true underlying anatomy and physiology is unknown. We have no way of knowing in a given scan how various factors are confounding the data: statistical noise; biological variability; patient motion; scattered radiation, dead time, and other data contaminants. Simulation allows us to isolate a single factor of interest, for instance when researchers perform multiple simulations of the same imaging situation to determine the effect of statistical noise or biological variability. Simulations are also increasingly used as a design optimization tool for tomographic scanners. This article gives an overview of the mechanics of emission and transmission tomography simulation, reviews some of the publicly available simulation tools, and discusses trade-offs between the accuracy and efficiency of simulations.
NASA Astrophysics Data System (ADS)
Liu, Shuangquan; Zhang, Bin; Wang, Xin; Li, Lin; Chen, Yan; Liu, Xin; Liu, Fei; Shan, Baoci; Bai, Jing
2011-02-01
A dual-modality imaging system for simultaneous fluorescence molecular tomography (FMT) and positron emission tomography (PET) of small animals has been developed. The system consists of a noncontact 360°-projection FMT module and a flat panel detector pair based PET module, which are mounted orthogonally for the sake of eliminating cross interference. The FMT images and PET data are simultaneously acquired by employing dynamic sampling mode. Phantom experiments, in which the localization and range of radioactive and fluorescence probes are exactly indicated, have been carried out to verify the feasibility of the system. An experimental tumor-bearing mouse is also scanned using the dual-modality simultaneous imaging system, the preliminary fluorescence tomographic images and PET images demonstrate the in vivo performance of the presented dual-modality system.
Fast tomosynthesis for lung cancer detection using the SBDX geometry
NASA Astrophysics Data System (ADS)
Fahrig, Rebecca; Pineda, Angel R.; Solomon, Edward G.; Leung, Ann N.; Pelc, Norbert J.
2003-06-01
Radiology-based lung-cancer detection is a high-contrast imaging task, consisting of the detection of a small mass of tissue within much lower density lung parenchyma. This imaging task requires removal of confounding image details, fast image acquisition (< 0.1 s for pericardial region), low dose (comparable to a chest x-ray), high resolution (< 0.25 mm in-plane) and patient positioning flexibility. We present an investigation of tomosynthesis, implemented using the Scanning-Beam Digital X-ray System (SBDX), to achieve these goals. We designed an image-based computer model of tomosynthesis using a high-resolution (0.15-mm isotropic voxels), low-noise CT volume image of a lung phantom, numerically added spherical lesions and convolution-based tomographic blurring. Lesion visibility was examined as a function of half-tomographic angle for 2.5 and 4.0 mm diameter lesions. Gaussian distributed noise was added to the projected images. For lesions 2.5 mm and 4.0 mm in diameter, half-tomographic angles of at least 6° and 9° respectively were necessary before visualization of the lesions improved. The addition of noise for a dose equivalent to 1/10 that used for a standard chest radiograph did not significantly impair lesion detection. The results are promising, indicating that lung-cancer detection using a modified SBDX system is possible.
NASA Astrophysics Data System (ADS)
Kazantsev, Daniil; Pickalov, Valery; Nagella, Srikanth; Pasca, Edoardo; Withers, Philip J.
2018-01-01
In the field of computerized tomographic imaging, many novel reconstruction techniques are routinely tested using simplistic numerical phantoms, e.g. the well-known Shepp-Logan phantom. These phantoms cannot sufficiently cover the broad spectrum of applications in CT imaging where, for instance, smooth or piecewise-smooth 3D objects are common. TomoPhantom provides quick access to an external library of modular analytical 2D/3D phantoms with temporal extensions. In TomoPhantom, quite complex phantoms can be built using additive combinations of geometrical objects, such as, Gaussians, parabolas, cones, ellipses, rectangles and volumetric extensions of them. Newly designed phantoms are better suited for benchmarking and testing of different image processing techniques. Specifically, tomographic reconstruction algorithms which employ 2D and 3D scanning geometries, can be rigorously analyzed using the software. TomoPhantom also provides a capability of obtaining analytical tomographic projections which further extends the applicability of software towards more realistic, free from the "inverse crime" testing. All core modules of the package are written in the C-OpenMP language and wrappers for Python and MATLAB are provided to enable easy access. Due to C-based multi-threaded implementation, volumetric phantoms of high spatial resolution can be obtained with computational efficiency.
Dethlefs, Christopher R.; Piotrowicz, Justin; Van Avermaete, Tony; Maki, Jeff; Gerstler, Steve; Leevy, W. M.
2017-01-01
Biomedical imaging modalities like computed tomography (CT) and magnetic resonance (MR) provide excellent platforms for collecting three-dimensional data sets of patient or specimen anatomy in clinical or preclinical settings. However, the use of a virtual, on-screen display limits the ability of these tomographic images to fully convey the anatomical information embedded within. One solution is to interface a biomedical imaging data set with 3D printing technology to generate a physical replica. Here we detail a complementary method to visualize tomographic imaging data with a hand-held model: Sub Surface Laser Engraving (SSLE) of crystal glass. SSLE offers several unique benefits including: the facile ability to include anatomical labels, as well as a scale bar; streamlined multipart assembly of complex structures in one medium; high resolution in the X, Y, and Z planes; and semi-transparent shells for visualization of internal anatomical substructures. Here we demonstrate the process of SSLE with CT data sets derived from pre-clinical and clinical sources. This protocol will serve as a powerful and inexpensive new tool with which to visualize complex anatomical structures for scientists and students in a number of educational and research settings. PMID:28518066
Colorectal cancer screening with virtual colonoscopy
NASA Astrophysics Data System (ADS)
Ge, Yaorong; Vining, David J.; Ahn, David K.; Stelts, David R.
1999-05-01
Early detection and removal of colorectal polyps have been proven to reduce mortality from colorectal carcinoma (CRC), the second leading cause of cancer deaths in the United States. Unfortunately, traditional techniques for CRC examination (i.e., barium enema, sigmoidoscopy, and colonoscopy) are unsuitable for mass screening because of either low accuracy or poor public acceptance, costs, and risks. Virtual colonoscopy (VC) is a minimally invasive alternative that is based on tomographic scanning of the colon. After a patient's bowel is optimally cleansed and distended with gas, a fast tomographic scan, typically helical computed tomography (CT), of the abdomen is performed during a single breath-hold acquisition. Two-dimensional (2D) slices and three-dimensional (3D) rendered views of the colon lumen generated from the tomographic data are then examined for colorectal polyps. Recent clinical studies conducted at several institutions including ours have shown great potential for this technology to be an effective CRC screening tool. In this paper, we describe new methods to improve bowel preparation, colon lumen visualization, colon segmentation, and polyp detection. Our initial results show that VC with the new bowel preparation and imaging protocol is capable of achieving accuracy comparable to conventional colonoscopy and our new algorithms for image analysis contribute to increased accuracy and efficiency in VC examinations.
Contribution of computed tomography to the investigation of La Tene culture iron artefacts
NASA Astrophysics Data System (ADS)
Vopálenský, M.; Sankot, P.; Fořt, M.; Kumpová, I.; Vavřík, D.
2017-07-01
The X-ray tomographic study was realized in addition to the standard X-ray radiography for the purpose of the new conservation work upon the La Tene culture iron artifacts from the collections of the National Museum in Prague. These artifacts are heavily damaged by the corrosion, avoiding thus an effective visual exploration. The work shows that even details, which are shallow compared to the artifact thickness and therefore not detectable in standard radiographic images, can be made visible in 3D models obtained tomografically. The tomographic data acquisition was performed utilizing the unique TORATOM device, equipped with a large area X-ray detector with Gadox scintillator. The tomographic reconstruction revealed insufficiencies in the earlier conservation processes of the La Tene culture swords, as well as so-far unknown details, such as the exact sword shapes and their decoration. These new findings allowed better classifying of the artifacts. Tomography also helped in visualizing details of iron clips that are completely hidden under the rust, making thus the technology of the clip formation clearly observable. With this work, it has been proven that tomography can bear valuable new information compared to the standard X-ray radiography commonly used in the investigation of iron archeological artifacts.
Lane, John I; Witte, Robert J; Driscoll, Colin L W; Shallop, Jon K; Beatty, Charles W; Primak, Andrew N
2007-08-01
To use the improved resolution available with 64-slice multidetector computed tomography (MDCT) in vivo to localize the cochlear implant electrode array within the basal turn. Sixty-four-slice MDCT examinations of the temporal bones were retrospectively reviewed in 17 patients. Twenty-three implants were evaluated. Tertiary referral facility. All patients with previous cochlear implantation evaluated at our center between January 2004 and March 2006 were offered a computed tomographic examination as part of the study. In addition, preoperative computed tomographic examinations in patients being evaluated for a second bilateral device were included. Sixty-four-slice MDCT examination of the temporal bones. Localization of the electrode array within the basal turn from multiplanar reconstructions of the cochlea. Twenty-three implants were imaged in 17 patients. We were able to localize the electrode array within the scala tympani within the basal turn in 10 implants. In 3 implants, the electrode array was localized to the scala vestibuli. Migration of the electrode array from scala tympani to scala vestibuli was observed in three implants. Of the 7 implants in which localization of the electrode array was indeterminate, all had disease entities that obscured the definition of the normal cochlear anatomy. Sixty-four-slice MDCT with multiplanar reconstructions of the postoperative cochlea after cochlear implantation allows for accurate localization of the electrode array within the basal turn where normal cochlear anatomy is not obscured by the underlying disease process. Correlating the position of the electrode in the basal turn with surgical technique and implant design could be helpful in improving outcomes.
Computed tomographic anatomy of the equine foot.
Claerhoudt, S; Bergman, E H J; Saunders, J H
2014-10-01
This study describes a detailed computed tomographic reference of the normal equine foot. Ten forefeet of five adult cadavers, without evidence of orthopaedic disease, were used. Computed tomography (CT) was performed on all feet. Two-millimetre thick transverse slices were obtained, and sagittal and dorsal planes were reformatted. The CT images were matched with the corresponding anatomic slices. The phalanges and the distal sesamoid bone showed excellent detail. The extensor and flexor tendons (including their attachments) could be clearly evaluated. The collateral (sesamoidean) ligaments could be readily located, but were difficult to delineate at their proximal attachment. The distal digital annular ligament could only be distinguished from the deep digital flexor tendon proximal to the distal sesamoid bone, and its proximal attachment could be identified, but not its distal insertion. Small ligaments (impar ligament, chondrosesamoidean, chondrocoronal and chondrocompedal ligaments, axial and abaxial palmar ligaments of the proximal inter-phalangeal joint) were seen with difficulty and not at all slices. The joint capsules could not be delineated from the surrounding soft tissue structures. The lateral and medial proprius palmar digital artery and vein could be visualized occasionally on some slices. The ungular cartilages, corium and hoof wall layering were seen. The nerves, the articular and fibrocartilage of the distal sesamoid bone and the chondroungular ligament could not be assessed. Computed tomography of the equine foot can be of great value when results of radiography and ultrasonography are inconclusive. Images obtained in this study may serve as reference for CT of the equine foot. © 2013 Blackwell Verlag GmbH.
Computer-aided teniae coli detection using height maps from computed tomographic colonography images
NASA Astrophysics Data System (ADS)
Wei, Zhuoshi; Yao, Jianhua; Wang, Shijun; Summers, Ronald M.
2011-03-01
Computed tomographic colonography (CTC) is a minimally invasive technique for colonic polyps and cancer screening. Teniae coli are three bands of longitudinal smooth muscle on the colon surface. They are parallel, equally distributed on the colon wall, and form a triple helix structure from the appendix to the sigmoid colon. Because of their characteristics, teniae coli are important anatomical meaningful landmarks on human colon. This paper proposes a novel method for teniae coli detection on CT colonography. We first unfold the three-dimensional (3D) colon using a reversible projection technique and compute the two-dimensional (2D) height map of the unfolded colon. The height map records the elevation of colon surface relative to the unfolding plane, where haustral folds corresponding to high elevation points and teniae to low elevation points. The teniae coli are detected on the height map and then projected back to the 3D colon. Since teniae are located where the haustral folds meet, we break down the problem by first detecting haustral folds. We apply 2D Gabor filter banks to extract fold features. The maximum response of the filter banks is then selected as the feature image. The fold centers are then identified based on piecewise thresholding on the feature image. Connecting the fold centers yields a path of the folds. Teniae coli are finally extracted as lines running between the fold paths. Experiments were carried out on 7 cases. The proposed method yielded a promising result with an average normalized RMSE of 5.66% and standard deviation of 4.79% of the circumference of the colon.
Wang, Guangli; Zhang, Chengqi; Li, Mingying; Deng, Kai; Li, Wei
2014-01-01
To evaluate the feasibility of multiparameter quantitative measurement lung cancer by Gemstone Spectral Imaging (GSI) high-definition computed tomography. Seventy-seven patients who were found to have a lung mass or a nodule by CT plain scan for the first time received chest contrast CT scan with GSI mode on high-definition computed tomography. The GSI viewer was used to display the spectral curve, iodine-based images, water-based images, and 101 sets of monochromatic images of a selected region of interest from the relative homogeneous area of the mass or nodule. Iodine concentration, water concentration, spectral curve slope, and CT values at 40 keV of the region of interest were measured. Finally, 68 eligible patients were divided into a pneumonia group (n = 24) and a malignant tumor group (n = 44, including squamous carcinoma, n = 29, and adenocarcinoma, n = 15). Significant differences existed in iodine concentration (t = 6.459), spectral curve slope (t = 6.276), and CT values at 40 keV (t = 6.698) between the pneumonia group and the malignant tumor group (P < 0.05), as well as between squamous carcinoma and adenocarcinoma (t = 6.494, 5.634, 6.091, respectively, P < 0.05), whereas water concentrations were found to have no difference between the 2 groups (t = 0.082, P > 0.05) and between the 2 types of malignant tumors (t = 1.234, P > 0.05). High-definition computed tomographic GSI technique might be helpful to differentiate lung cancer from lung benign lesions by providing qualitative and quantitative information.
Xu, Rende; Li, Chenguang; Qian, Juying; Ge, Junbo
2015-11-01
Invasive fractional flow reserve (FFR) is the gold standard for the determination of physiologic stenosis severity and the need for revascularization. FFR computed from standard acquired coronary computed tomographic angiography datasets (FFRCT) is an emerging technology which allows calculation of FFR using resting image data from coronary computed tomographic angiography (CCTA). However, the diagnostic accuracy of FFRCT in the evaluation of lesion-specific myocardial ischemia remains to be confirmed, especially in patients with intermediate coronary stenosis. We performed an integrated analysis of data from 3 prospective, international, and multicenter trials, which assessed the diagnostic performance of FFRCT using invasive FFR as a reference standard. Three studies evaluating 609 patients and 1050 vessels were included. The total calculated sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of FFRCT were 82.8%, 77.7%, 60.8%, 91.6%, and 79.2%, respectively, for the per-vessel analysis, and 89.4%, 70.5%, 69.7%, 89.7%, and 78.7%, respectively, for the per-patient analysis. Compared with CCTA alone, FFRCT demonstrated significantly improved accuracy (P < 0.001) in detecting lesion-specific ischemia. In patients with intermediate coronary stenosis, FFRCT remained both highly sensitive and specific with respect to the diagnosis of ischemia. In conclusion, FFRCT appears to be a reliable noninvasive alternative to invasive FFR, as it demonstrates high accuracy in the determination of anatomy and lesion-specific ischemia, which justifies the performance of additional randomized controlled trials to evaluate both the clinical benefits and the cost-effectiveness of FFRCT-guided coronary revascularization.
Lara-Mendes, Sônia T de O; Barbosa, Camila de Freitas M; Santa-Rosa, Caroline C; Machado, Vinícius C
2018-05-01
The aim of this study was to describe a guided endodontic technique that facilitates access to root canals of molars presenting with pulp calcifications. A 61-year-old woman presented to our service with pain in the upper left molar region. The second and third left molars showed signs of apical periodontitis confirmed by the cone-beam computed tomographic (CBCT) scans brought to us by the patient at the initial appointment. Conventional endodontic treatment was discontinued given the difficulty in locating the root canals. Intraoral scanning and the CBCT scans were used to plan the access to the calcified canals by means of implant planning software. Guides were fabricated through rapid prototyping and allowed for the correct orientation of a cylindrical drill used to provide access through the calcifications. Second to that, the root canals were prepared with reciprocating endodontic instruments and rested for 2 weeks with intracanal medication. Subsequently, canals were packed with gutta-percha cones using the hydraulic compression technique. Permanent restorations of the access cavities were performed. By comparing the tomographic images, the authors observed a drastic reduction of the periapical lesions as well as the absence of pain symptoms after 3 months. This condition was maintained at the 1-year follow-up. The guided endodontic technique in maxillary molars was shown to be a fast, safe, and predictable therapy and can be regarded as an excellent option for the location of calcified root canals, avoiding failures in complex cases. Copyright © 2018 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Romanowicz, Barbara; Yuan, Kaiqing; Masson, Yder; Adourian, Sevan
2017-04-01
We have recently constructed the first global whole mantle radially anisotropic shear wave velocity model based on time domain full waveform inversion and numerical wavefield computations using the Spectral Element Method (French et al., 2013; French and Romanowicz, 2014). This model's most salient features are broad chimney-like low velocity conduits, rooted within the large-low-shear-velocity provinces (LLSVPs) at the base of the mantle, and extending from the core-mantle boundary up through most of the lower mantle, projecting to the earth's surface in the vicinity of major hotspots. The robustness of these features is confirmed through several non-linear synthetic tests, which we present here, including several iterations of inversion using a different starting model than that which served for the published model. The roots of these not-so-classical "plumes" are regions of more pronounced low shear velocity. While the detailed structure is not yet resolvable tomographically, at least two of them contain large (>800 km diameter) ultra-low-velocity zones (ULVZs), one under Hawaii (Cottaar and Romanowicz, 2012) and the other one under Samoa (Thorne et al., 2013). Through 3D numerical forward modelling of Sdiff phases down to 10s period, using data from broadband arrays illuminating the base of the Iceland plume from different directions, we show that such a large ULVZ also exists at the root of this plume, embedded within a taller region of moderately reduced low shear velocity, such as proposed by He et al. (2015). We also show that such a wide, but localized ULVZ is unique in a broad region around the base of the Iceland Plume. Because of the intense computational effort required for forward modelling of trial structures, to first order this ULVZ is represented by a cylindrical structure of diameter 900 km, height 20 km and velocity reduction 20%. To further refine the model, we have developed a technique which we call "tomographic telescope", in which we are able to compute the teleseismic wavefield down to periods of 10s only once, while subsequent iterations require numerical wavefield computations only within the target region, in this case, around the base of the Iceland plume. We describe the method and preliminary results of its implementation.
Dulski, Kamil; Niedźwiecki, Szymon; Alfs, Dominika; Białas, Piotr; Curceanu, Catalina; Czerwiński, Eryk; Danel, Andrzej; Gajos, Aleksander; Głowacz, Bartosz; Gorgol, Marek; Hiesmayr, Beatrix; Jasińska, Bożena; Kacprzak, Krzysztof; Kamińska, Daria; Kapłon, Łukasz; Kochanowski, Andrzej; Korcyl, Grzegorz; Kowalski, Paweł; Kozik, Tomasz; Krzemień, Wojciech; Kubicz, Ewelina; Kucharek, Mateusz; Mohammed, Muhsin; Pawlik-Niedźwiecka, Monika; Pałka, Marek; Raczyński, Lech; Rudy, Zbigniew; Rundel, Oleksandr; Sharma, Neha G.; Silarski, Michał; Uchacz, Tomasz; Wiślicki, Wojciech; Zgardzińska, Bożena; Zieliński, Marcin; Moskal, Paweł
2017-01-01
A novel plastic scintillator is developed for the application in the digital positron emission tomography (PET). The novelty of the concept lies in application of the 2-(4-styrylphenyl)benzoxazole as a wavelength shifter. The substance has not been used as scintillator dopant before. A dopant shifts the scintillation spectrum towards longer wavelengths making it more suitable for applications in scintillators of long strips geometry and light detection with digital silicon photomultipliers. These features open perspectives for the construction of the cost-effective and MRI-compatible PET scanner with the large field of view. In this article we present the synthesis method and characterize performance of the elaborated scintillator by determining its light emission spectrum, light emission efficiency, rising and decay time of the scintillation pulses and resulting timing resolution when applied in the positron emission tomography. The optimal concentration of the novel wavelength shifter was established by maximizing the light output and it was found to be 0.05 ‰ for cuboidal scintillator with dimensions of 14 mm x 14 mm x 20 mm. PMID:29176834
NASA Astrophysics Data System (ADS)
Salas-García, Irene; Fanjul-Vélez, Félix; Arce-Diego, José Luis
2012-03-01
The development of Photodynamic Therapy (PDT) predictive models has become a valuable tool for an optimal treatment planning, monitoring and dosimetry adjustment. A few attempts have achieved a quite complete characterization of the complex photochemical and photophysical processes involved, even taking into account superficial fluorescence in the target tissue. The present work is devoted to the application of a predictive PDT model to obtain fluorescence tomography information during PDT when applied to a skin disease. The model takes into account the optical radiation distribution, a non-homogeneous topical photosensitizer distribution, the time dependent photochemical interaction and the photosensitizer fluorescence emission. The results show the spatial evolution of the photosensitizer fluorescence emission and the amount of singlet oxygen produced during PDT. The depth dependent photosensitizer fluorescence emission obtained is essential to estimate the spatial photosensitizer concentration and its degradation due to photobleaching. As a consequence the proposed approach could be used to predict the photosensitizer fluorescence tomographic measurements during PDT. The singlet oxygen prediction could also be employed as a valuable tool to predict the short term treatment outcome.
Wieczorek, Anna; Dulski, Kamil; Niedźwiecki, Szymon; Alfs, Dominika; Białas, Piotr; Curceanu, Catalina; Czerwiński, Eryk; Danel, Andrzej; Gajos, Aleksander; Głowacz, Bartosz; Gorgol, Marek; Hiesmayr, Beatrix; Jasińska, Bożena; Kacprzak, Krzysztof; Kamińska, Daria; Kapłon, Łukasz; Kochanowski, Andrzej; Korcyl, Grzegorz; Kowalski, Paweł; Kozik, Tomasz; Krzemień, Wojciech; Kubicz, Ewelina; Kucharek, Mateusz; Mohammed, Muhsin; Pawlik-Niedźwiecka, Monika; Pałka, Marek; Raczyński, Lech; Rudy, Zbigniew; Rundel, Oleksandr; Sharma, Neha G; Silarski, Michał; Uchacz, Tomasz; Wiślicki, Wojciech; Zgardzińska, Bożena; Zieliński, Marcin; Moskal, Paweł
2017-01-01
A novel plastic scintillator is developed for the application in the digital positron emission tomography (PET). The novelty of the concept lies in application of the 2-(4-styrylphenyl)benzoxazole as a wavelength shifter. The substance has not been used as scintillator dopant before. A dopant shifts the scintillation spectrum towards longer wavelengths making it more suitable for applications in scintillators of long strips geometry and light detection with digital silicon photomultipliers. These features open perspectives for the construction of the cost-effective and MRI-compatible PET scanner with the large field of view. In this article we present the synthesis method and characterize performance of the elaborated scintillator by determining its light emission spectrum, light emission efficiency, rising and decay time of the scintillation pulses and resulting timing resolution when applied in the positron emission tomography. The optimal concentration of the novel wavelength shifter was established by maximizing the light output and it was found to be 0.05 ‰ for cuboidal scintillator with dimensions of 14 mm x 14 mm x 20 mm.
Clinical applications with the HIDAC positron camera
NASA Astrophysics Data System (ADS)
Frey, P.; Schaller, G.; Christin, A.; Townsend, D.; Tochon-Danguy, H.; Wensveen, M.; Donath, A.
1988-06-01
A high density avalanche chamber (HIDAC) positron camera has been used for positron emission tomographic (PET) imaging in three different human studies, including patients presenting with: (I) thyroid diseases (124 cases); (II) clinically suspected malignant tumours of the pharynx or larynx (ENT) region (23 cases); and (III) clinically suspected primary malignant and metastatic tumours of the liver (9 cases, 19 PET scans). The positron emitting radiopharmaceuticals used for the three studies were Na 124I (4.2 d half-life) for the thyroid, 55Co-bleomycin (17.5 h half-life) for the ENT-region and 68Ga-colloid (68 min half-life) for the liver. Tomographic imaging was performed: (I) 24 h after oral Na 124I administration to the thyroid patients, (II) 18 h after intraveneous administration of 55Co-bleomycin to the ENT patients and (III) 20 min following the intraveneous injection of 68Ga-colloid to the liver tumour patients. Three different imaging protocols were used with the HIDAC positron camera to perform appropriate tomographic imaging in each patient study. Promising results were obtained in all three studies, particularly in tomographic thyroid imaging, where a significant clinical contribution is made possible for diagnosis and therapy planning by the PET technique. In the other two PET studies encouraging results were obtained for the detection and precise localisation of malignant tumour disease including an estimate of the functional liver volume based on the reticulo-endothelial-system (RES) of the liver, obtained in vivo, and the three-dimensional display of liver PET data using shaded graphics techniques. The clinical significance of the overall results obtained in both the ENT and the liver PET study, however, is still uncertain and the respective role of PET as a new imaging modality in these applications is not yet clearly established. To appreciate the clinical impact made by PET in liver and ENT malignant tumour staging needs further investigation, and more detailed data on a larger number of clinical and experimental PET scans will be necessary for definitive evaluation. Nevertheless, the HIDAC positron camera may be used for clinical PET imaging in well-defined patient cases, particularly in situations where both high spatial resolution is desired in the reconstructed image of the examined pathological condition and at the same time "static" PET imaging may be adequate, as is the case in thyroid-, ENT- and liver tomographic imaging using the HIDAC positron camera.
Tomography of the Red Supergiant Star MU Cep
NASA Astrophysics Data System (ADS)
Kravchenko, Kateryna
2018-04-01
We present a tomographic method allowing to recover the velocity field at different optical depths in a stellar atmosphere. It is based on the computation of the contribution function to identify the depth of formation of spectral lines in order to construct numerical masks probing different optical depths. These masks are cross-correlated with observed spectra to extract information about the average shape of lines forming at a given optical depth and to derive the velocity field projected on the line of sight. We applied this method to series of spectra of the red supergiant star mu Cep and derived velocities in different atmospheric layers. The resulting velocity variations reveal complex atmospheric dynamics and indicate that convective cells are present in the atmosphere of the mu Cep. The mu Cep velocities were compared with those obtained by applying the tomographic masks to series of snapshot spectra from 3D radiative-hydrodynamics CO5BOLD simulations.
System for tomographic determination of the power distribution in electron beams
Elmer, J.W.; Teruya, A.T.; O'Brien, D.W.
1995-01-17
A tomographic technique is disclosed for measuring the current density distribution in electron beams using electron beam profile data acquired from a modified Faraday cup to create an image of the current density in high and low power beams. The modified Faraday cup includes a narrow slit and is rotated by a stepper motor and can be moved in the x, y and z directions. The beam is swept across the slit perpendicular thereto and controlled by deflection coils, and the slit rotated such that waveforms are taken every few degrees form 0[degree] to 360[degree] and the waveforms are recorded by a digitizing storage oscilloscope. Two-dimensional and three-dimensional images of the current density distribution in the beam can be reconstructed by computer tomography from this information, providing quantitative information about the beam focus and alignment. 12 figures.
Image-guided therapies for myocardial repair: concepts and practical implementation
Bengel, Frank M.; George, Richard T.; Schuleri, Karl H.; Lardo, Albert C.; Wollert, Kai C.
2013-01-01
Cell- and molecule-based therapeutic strategies to support wound healing and regeneration after myocardial infarction (MI) are under development. These emerging therapies aim at sustained preservation of ventricular function by enhancing tissue repair after myocardial ischaemia and reperfusion. Such therapies will benefit from guidance with regard to timing, regional targeting, suitable candidate selection, and effectiveness monitoring. Such guidance is effectively obtained by non-invasive tomographic imaging. Infarct size, tissue characteristics, muscle mass, and chamber geometry can be determined by magnetic resonance imaging and computed tomography. Radionuclide imaging can be used for the tracking of therapeutic agents and for the interrogation of molecular mechanisms such as inflammation, angiogenesis, and extracellular matrix activation. This review article portrays the hypothesis that an integrated approach with an early implementation of structural and molecular tomographic imaging in the development of novel therapies will provide a framework for achieving the goal of improved tissue repair after MI. PMID:23720377
Tomographic techniques for the study of exceptionally preserved fossils
Sutton, Mark D
2008-01-01
Three-dimensional fossils, especially those preserving soft-part anatomy, are a rich source of palaeontological information; they can, however, be difficult to work with. Imaging of serial planes through an object (tomography) allows study of both the inside and outside of three-dimensional fossils. Tomography may be performed using physical grinding or sawing coupled with photography, through optical techniques of serial focusing, or using a variety of scanning technologies such as neutron tomography, magnetic resonance imaging and most usefully X-ray computed tomography. This latter technique is applicable at a variety of scales, and when combined with a synchrotron X-ray source can produce very high-quality data that may be augmented by phase-contrast information to enhance contrast. Tomographic data can be visualized in several ways, the most effective of which is the production of isosurface-based ‘virtual fossils’ that can be manipulated and dissected interactively. PMID:18426749
TOMOGRAPHIC MORPHOLOGICAL STUDY OF THE CRANIUM AND ITS CORRELATION WITH CRANIAL HALO USE IN ADULTS
ALMEIDA, TIAGO FERREIRA DE; CHARAFEDDINE, HOMAR TOLEDO; ARAÚJO, FERNANDO FLORES DE; CRISTANTE, ALEXANDRE FOGAÇA; MARCON, RAPHAEL MARTUS; LETAIF, OLAVO BIRAGHI
2017-01-01
ABSTRACT Objective: To evaluate using tomographic study the thickness of the cranial board at the insertions points of the cranial halo pins in adults Methods: This is a retrospective, cross-sectional, descriptive analysis of Computed Tomography (CT) scans of adult patients' crania. The study included adults between 20 and 50 years without cranial abnormalities. We excluded any exam with cranial abnormalities Results: We analyzed 50 CT scans, including 27 men and 23 women, at the original insertion points and alternative points (1 and 2 cm above the frontal and parietal bones). The average values were 7.4333 mm in the frontal bone and 6.0290 mm in the parietal bone Conclusion: There was no statistically significant difference between the classical and alternative points, making room for alternative fixings and safer introduction of the pins, if necessary.Level of Evidence II, Retrospective Study. PMID:28642643
NASA Astrophysics Data System (ADS)
Garay, Michael J.; Davis, Anthony B.; Diner, David J.
2016-12-01
We present initial results using computed tomography to reconstruct the three-dimensional structure of an aerosol plume from passive observations made by the Multi-angle Imaging SpectroRadiometer (MISR) instrument on NASA's Terra satellite. MISR views the Earth from nine different angles at four visible and near-infrared wavelengths. Adopting the 672 nm channel, we treat each view as an independent measure of aerosol optical thickness along the line of sight at 1.1 km resolution. A smoke plume over dark water is selected as it provides a more tractable lower boundary condition for the retrieval. A tomographic algorithm is used to reconstruct the horizontal and vertical aerosol extinction field for one along-track slice from the path of all camera rays passing through a regular grid. The results compare well with ground-based lidar observations from a nearby Micropulse Lidar Network site.
Laser-wakefield accelerators as hard x-ray sources for 3D medical imaging of human bone
Cole, J. M.; Wood, J. C.; Lopes, N. C.; Poder, K.; Abel, R. L.; Alatabi, S.; Bryant, J. S. J.; Jin, A.; Kneip, S.; Mecseki, K.; Symes, D. R.; Mangles, S. P. D.; Najmudin, Z.
2015-01-01
A bright μm-sized source of hard synchrotron x-rays (critical energy Ecrit > 30 keV) based on the betatron oscillations of laser wakefield accelerated electrons has been developed. The potential of this source for medical imaging was demonstrated by performing micro-computed tomography of a human femoral trabecular bone sample, allowing full 3D reconstruction to a resolution below 50 μm. The use of a 1 cm long wakefield accelerator means that the length of the beamline (excluding the laser) is dominated by the x-ray imaging distances rather than the electron acceleration distances. The source possesses high peak brightness, which allows each image to be recorded with a single exposure and reduces the time required for a full tomographic scan. These properties make this an interesting laboratory source for many tomographic imaging applications. PMID:26283308
Optimization-Based Approach for Joint X-Ray Fluorescence and Transmission Tomographic Inversion
DOE Office of Scientific and Technical Information (OSTI.GOV)
Di, Zichao; Leyffer, Sven; Wild, Stefan M.
2016-01-01
Fluorescence tomographic reconstruction, based on the detection of photons coming from fluorescent emission, can be used for revealing the internal elemental composition of a sample. On the other hand, conventional X-ray transmission tomography can be used for reconstructing the spatial distribution of the absorption coefficient inside a sample. In this work, we integrate both X-ray fluorescence and X-ray transmission data modalities and formulate a nonlinear optimization-based approach for reconstruction of the elemental composition of a given object. This model provides a simultaneous reconstruction of both the quantitative spatial distribution of all elements and the absorption effect in the sample. Mathematicallymore » speaking, we show that compared with the single-modality inversion (i.e., the X-ray transmission or fluorescence alone), the joint inversion provides a better-posed problem, which implies a better recovery. Therefore, the challenges in X-ray fluorescence tomography arising mainly from the effects of self-absorption in the sample are partially mitigated. The use of this technique is demonstrated on the reconstruction of several synthetic samples.« less
J-PET detector system for studies of the electron-positron annihilations
NASA Astrophysics Data System (ADS)
Pawlik-Niedźwiecka, M.; Khreptak, O.; Gajos, A.; Wieczorek, A.; Alfs, D.; Bednarski, T.; Białas, P.; Curceanu, C.; Czerwiński, E.; Dulski, K.; Głowacz, B.; Gupta-Sharma, N.; Gorgol, M.; Hiesmayr, B. C.; Jasińska, B.; Kamińska, D.; Korcyl, G.; Kowalski, P.; Krzmień, W.; Krawczyk, N.; Kubicz, E.; Mohammed, M.; Niedźwiecki, Sz.; Raczyński, L.; Rudy, Z.; Silarski, M.; Wiślicki, W.; Zgardzińska, B.; Zieliński, M.; Moskal, P.
2016-11-01
Jagiellonian Positron Emission Tomograph (J-PET) has been recently constructed at the Jagiellonian University as a prototype of a cost-effective scanner for the metabolic imaging of the whole human body. J-PET detector is optimized for the measurement of momentum and polarization of photons from the electron-positron annihilations. It is built out of strips of plastic scintillators, forming three cylindrical layers. As detector of gamma quanta it will be used for studies of discrete symmetries and multiparticle entanglement of photons originating from the decays of ortho-positronium atoms.
NASA Technical Reports Server (NTRS)
Alfano, Robert R. (Inventor); Cai, Wei (Inventor)
2007-01-01
A reconstruction technique for reducing computation burden in the 3D image processes, wherein the reconstruction procedure comprises an inverse and a forward model. The inverse model uses a hybrid dual Fourier algorithm that combines a 2D Fourier inversion with a 1D matrix inversion to thereby provide high-speed inverse computations. The inverse algorithm uses a hybrid transfer to provide fast Fourier inversion for data of multiple sources and multiple detectors. The forward model is based on an analytical cumulant solution of a radiative transfer equation. The accurate analytical form of the solution to the radiative transfer equation provides an efficient formalism for fast computation of the forward model.
Reagan, Adrian C; Mallinson, Paul I; O'Connell, Timothy; McLaughlin, Patrick D; Krauss, Bernhard; Munk, Peter L; Nicolaou, Savvas; Ouellette, Hugue A
2014-01-01
Computed tomography (CT) is often used to assess the presence of occult fractures when plain radiographs are equivocal in the acute traumatic setting. While providing increased spatial resolution, conventional computed tomography is limited in the assessment of bone marrow edema, a finding that is readily detectable on magnetic resonance imaging (MRI).Dual-energy CT has recently been shown to demonstrate patterns of bone marrow edema similar to corresponding MRI studies. Dual-energy CT may therefore provide a convenient modality for further characterizing acute bony injury when MRI is not readily available. We report our initial experiences of 4 cases with imaging and clinical correlation.
Spectroscopic micro-tomography of metallic-organic composites by means of photon-counting detectors
NASA Astrophysics Data System (ADS)
Pichotka, M.; Jakubek, J.; Vavrik, D.
2015-12-01
The presumed capabilities of photon counting detectors have aroused major expectations in several fields of research. In the field of nuclear imaging ample benefits over standard detectors are to be expected from photon counting devices. First of all a very high contrast, as has by now been verified in numerous experiments. The spectroscopic capabilities of photon counting detectors further allow material decomposition in computed tomography and therefore inherently adequate beam hardening correction. For these reasons measurement setups featuring standard X-ray tubes combined with photon counting detectors constitute a possible replacement of the much more cost intensive tomographic setups at synchrotron light-sources. The actual application of photon counting detectors in radiographic setups in recent years has been impeded by a number of practical issues, above all by restrictions in the detectors size. Currently two tomographic setups in Czech Republic feature photon counting large-area detectors (LAD) fabricated in Prague. The employed large area hybrid pixel-detector assemblies [1] consisting of 10×10/10×5 Timepix devices have a surface area of 143×143 mm2 / 143×71,5 mm2 respectively, suitable for micro-tomographic applications. In the near future LAD devices featuring the Medipix3 readout chip as well as heavy sensors (CdTe, GaAs) will become available. Data analysis is obtained by a number of in house software tools including iterative multi-energy volume reconstruction.In this paper tomographic analysis of of metallic-organic composites is employed to illustrate the capabilities of our technology. Other than successful material decomposition by spectroscopic tomography we present a method to suppress metal artefacts under certain conditions.
Regional lipiodolized chemotherapy for cholangiocarcinoma associated with oral contraceptives.
McAleer, J. J.; Dickey, W.; Clarke, R.; Johnston, G. W.; Callender, M. E.
1987-01-01
We describe a case of cholangiocarcinoma in a young woman, who presented with cholestatic jaundice following oral contraceptive ingestion. Following diagnostic laparotomy she received intra-arterial 'lipiodolized' chemotherapy. Intravenous mitozantrone was given for 2 years and she is asymptomatic, with computed tomographic evidence of tumour response, 27 months after diagnosis. We suggest that this form of treatment is of value for cholangiocarcinoma. PMID:2821526
Feasibility of RACT for 3D dose measurement and range verification in a water phantom.
Alsanea, Fahed; Moskvin, Vadim; Stantz, Keith M
2015-02-01
The objective of this study is to establish the feasibility of using radiation-induced acoustics to measure the range and Bragg peak dose from a pulsed proton beam. Simulation studies implementing a prototype scanner design based on computed tomographic methods were performed to investigate the sensitivity to proton range and integral dose. Derived from thermodynamic wave equation, the pressure signals generated from the dose deposited from a pulsed proton beam with a 1 cm lateral beam width and a range of 16, 20, and 27 cm in water using Monte Carlo methods were simulated. The resulting dosimetric images were reconstructed implementing a 3D filtered backprojection algorithm and the pressure signals acquired from a 71-transducer array with a cylindrical geometry (30 × 40 cm) rotated over 2π about its central axis. Dependencies on the detector bandwidth and proton beam pulse width were performed, after which, different noise levels were added to the detector signals (using 1 μs pulse width and a 0.5 MHz cutoff frequency/hydrophone) to investigate the statistical and systematic errors in the proton range (at 20 cm) and Bragg peak dose (of 1 cGy). The reconstructed radioacoustic computed tomographic image intensity was shown to be linearly correlated to the dose within the Bragg peak. And, based on noise dependent studies, a detector sensitivity of 38 mPa was necessary to determine the proton range to within 1.0 mm (full-width at half-maximum) (systematic error < 150 μm) for a 1 cGy Bragg peak dose, where the integral dose within the Bragg peak was measured to within 2%. For existing hydrophone detector sensitivities, a Bragg peak dose of 1.6 cGy is possible. This study demonstrates that computed tomographic scanner based on ionizing radiation-induced acoustics can be used to verify dose distribution and proton range with centi-Gray sensitivity. Realizing this technology into the clinic has the potential to significantly impact beam commissioning, treatment verification during particle beam therapy and image guided techniques.
Douglas, Pamela S; Pontone, Gianluca; Hlatky, Mark A; Patel, Manesh R; Norgaard, Bjarne L; Byrne, Robert A; Curzen, Nick; Purcell, Ian; Gutberlet, Matthias; Rioufol, Gilles; Hink, Ulrich; Schuchlenz, Herwig Walter; Feuchtner, Gudrun; Gilard, Martine; Andreini, Daniele; Jensen, Jesper M; Hadamitzky, Martin; Chiswell, Karen; Cyr, Derek; Wilk, Alan; Wang, Furong; Rogers, Campbell; De Bruyne, Bernard
2015-12-14
In symptomatic patients with suspected coronary artery disease (CAD), computed tomographic angiography (CTA) improves patient selection for invasive coronary angiography (ICA) compared with functional testing. The impact of measuring fractional flow reserve by CTA (FFRCT) is unknown. At 11 sites, 584 patients with new onset chest pain were prospectively assigned to receive either usual testing (n = 287) or CTA/FFR(CT) (n = 297). Test interpretation and care decisions were made by the clinical care team. The primary endpoint was the percentage of those with planned ICA in whom no significant obstructive CAD (no stenosis ≥50% by core laboratory quantitative analysis or invasive FFR < 0.80) was found at ICA within 90 days. Secondary endpoints including death, myocardial infarction, and unplanned revascularization were independently and blindly adjudicated. Subjects averaged 61 ± 11 years of age, 40% were female, and the mean pre-test probability of obstructive CAD was 49 ± 17%. Among those with intended ICA (FFR(CT)-guided = 193; usual care = 187), no obstructive CAD was found at ICA in 24 (12%) in the CTA/FFR(CT) arm and 137 (73%) in the usual care arm (risk difference 61%, 95% confidence interval 53-69, P< 0.0001), with similar mean cumulative radiation exposure (9.9 vs. 9.4 mSv, P = 0.20). Invasive coronary angiography was cancelled in 61% after receiving CTA/FFR(CT) results. Among those with intended non-invasive testing, the rates of finding no obstructive CAD at ICA were 13% (CTA/FFR(CT)) and 6% (usual care; P = 0.95). Clinical event rates within 90 days were low in usual care and CTA/FFR(CT) arms. Computed tomographic angiography/fractional flow reserve by CTA was a feasible and safe alternative to ICA and was associated with a significantly lower rate of invasive angiography showing no obstructive CAD. © The Author 2015. Published by Oxford University Press on behalf of the European Society of Cardiology.
Hendel, Michael D; Bryan, Jason A; Barsoum, Wael K; Rodriguez, Eric J; Brems, John J; Evans, Peter J; Iannotti, Joseph P
2012-12-05
Glenoid component malposition for anatomic shoulder replacement may result in complications. The purpose of this study was to define the efficacy of a new surgical method to place the glenoid component. Thirty-one patients were randomized for glenoid component placement with use of either novel three-dimensional computed tomographic scan planning software combined with patient-specific instrumentation (the glenoid positioning system group), or conventional computed tomographic scan, preoperative planning, and surgical technique, utilizing instruments provided by the implant manufacturer (the standard surgical group). The desired position of the component was determined preoperatively. Postoperatively, a computed tomographic scan was used to define and compare the actual implant location with the preoperative plan. In the standard surgical group, the average preoperative glenoid retroversion was -11.3° (range, -39° to 17°). In the glenoid positioning system group, the average glenoid retroversion was -14.8° (range, -27° to 7°). When the standard surgical group was compared with the glenoid positioning system group, patient-specific instrumentation technology significantly decreased (p < 0.05) the average deviation of implant position for inclination and medial-lateral offset. Overall, the average deviation in version was 6.9° in the standard surgical group and 4.3° in the glenoid positioning system group. The average deviation in inclination was 11.6° in the standard surgical group and 2.9° in the glenoid positioning system group. The greatest benefit of patient-specific instrumentation was observed in patients with retroversion in excess of 16°; the average deviation was 10° in the standard surgical group and 1.2° in the glenoid positioning system group (p < 0.001). Preoperative planning and patient-specific instrumentation use resulted in a significant improvement in the selection and use of the optimal type of implant and a significant reduction in the frequency of malpositioned glenoid implants. Novel three-dimensional preoperative planning, coupled with patient and implant-specific instrumentation, allows the surgeon to better define the preoperative pathology, select the optimal implant design and location, and then accurately execute the plan at the time of surgery.
Ichikawa, Makoto; Sato, Yuichi; Komatsu, Sei; Hirayama, Atsushi; Kodama, Kazuhisa; Saito, Satoshi
2007-06-01
Anomalous right coronary arteries (RCA) arising from the left sinus of Valsalva may cause myocardial ischemia. We evaluated morphological features of anomalous RCA by using multislice computed tomography (MSCT) in relation to myocardial ischemia provoked by myocardial perfusion single-photon emission computed tomography. MSCT was performed in a total of 3, 212 patients by using an Aquillion 16 and a Light Speed Ultra. Retrospective ECG-gated image reconstruction was performed. Volume rendering, axial and curved multiplanar reformatted images were analyzed for the determination of the origin and course of the RCA, the take-off angle of the RCA from the aorta, and size of the RCA orifice. Furthermore, virtual angioscopic images were also used for the evaluation of the RCA orifice structure. Anomalous origins of the RCA were found in 15 patients. In 13 patients, the RCA arose from the left sinus of Valsalva, and in 2 patients it arose from the left main coronary artery as a single coronary artery. The RCA coursed anteriorly between the ascending aorta and pulmonary artery in 14 patients, whereas it had a retroaortic course in 1 patient. Acute angle take-off (<30 degrees ) of the RCA from the aorta and the left main coronary artery was observed in 8 patients, intramural course of the RCA within the aortic wall was observed in 6 patients and a small RCA orifice was observed in 4 patients. Exercise-induced myocardial ischemia was present in 5 patients. Coursing between the aorta and pulmonary artery, acute angle take-off and intramural course were thought to be major causes of exercise-induced ischemia in patients with anomalous origins of the RCA.
Positron Emission Tomography - Computed Tomography (PET/CT)
... A-Z Positron Emission Tomography - Computed Tomography (PET/CT) Positron emission tomography (PET) uses small amounts of ... What is Positron Emission Tomography – Computed Tomography (PET/CT) Scanning? Positron emission tomography, also called PET imaging ...
Building a symbolic computer algebra toolbox to compute 2D Fourier transforms in polar coordinates.
Dovlo, Edem; Baddour, Natalie
2015-01-01
The development of a symbolic computer algebra toolbox for the computation of two dimensional (2D) Fourier transforms in polar coordinates is presented. Multidimensional Fourier transforms are widely used in image processing, tomographic reconstructions and in fact any application that requires a multidimensional convolution. By examining a function in the frequency domain, additional information and insights may be obtained. The advantages of our method include: •The implementation of the 2D Fourier transform in polar coordinates within the toolbox via the combination of two significantly simpler transforms.•The modular approach along with the idea of lookup tables implemented help avoid the issue of indeterminate results which may occur when attempting to directly evaluate the transform.•The concept also helps prevent unnecessary computation of already known transforms thereby saving memory and processing time.
Tomographic methods in flow diagnostics
NASA Technical Reports Server (NTRS)
Decker, Arthur J.
1993-01-01
This report presents a viewpoint of tomography that should be well adapted to currently available optical measurement technology as well as the needs of computational and experimental fluid dynamists. The goals in mind are to record data with the fastest optical array sensors; process the data with the fastest parallel processing technology available for small computers; and generate results for both experimental and theoretical data. An in-depth example treats interferometric data as it might be recorded in an aeronautics test facility, but the results are applicable whenever fluid properties are to be measured or applied from projections of those properties. The paper discusses both computed and neural net calibration tomography. The report also contains an overview of key definitions and computational methods, key references, computational problems such as ill-posedness, artifacts, missing data, and some possible and current research topics.
Comparison of computed tomography and complex motion tomography in the evaluation of cholesteatoma
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shaffer, K.A.
1984-08-01
High-resolution axial and coronal computed tomographic (CT) scans were compared with coronal and sagittal complex motion tomograms in patients with suspected middle ear cholesteatomas. Information on CT scans equaled or exceeded that on conventional complex motion tomograms in 16 of 17 patients, and in 11 it provided additional information. Soft-tissue resolution was superior with CT. In 14 patients who underwent surgery, CT provided information that was valuable to the surgeon. On the basis of this study, high-resolution CT is recommended as the preferred method for evaluating most patients with cholesteatomas of the temporal bone.
Advanced imaging in acute stroke management-Part I: Computed tomographic.
Saini, Monica; Butcher, Ken
2009-01-01
Neuroimaging is fundamental to stroke diagnosis and management. Non-contrast computed tomography (NCCT) has been the primary imaging modality utilized for this purpose for almost four decades. Although NCCT does permit identification of intracranial hemorrhage and parenchymal ischemic changes, insights into blood vessel patency and cerebral perfusion are limited. Advances in reperfusion strategies have made identification of potentially salvageable brain tissue a more practical concern. Advances in CT technology now permit identification of acute and chronic arterial lesions, as well as cerebral blood flow deficits. This review outlines principles of advanced CT image acquisition and its utility in acute stroke management.
Meaning of Interior Tomography
Wang, Ge; Yu, Hengyong
2013-01-01
The classic imaging geometry for computed tomography is for collection of un-truncated projections and reconstruction of a global image, with the Fourier transform as the theoretical foundation that is intrinsically non-local. Recently, interior tomography research has led to theoretically exact relationships between localities in the projection and image spaces and practically promising reconstruction algorithms. Initially, interior tomography was developed for x-ray computed tomography. Then, it has been elevated as a general imaging principle. Finally, a novel framework known as “omni-tomography” is being developed for grand fusion of multiple imaging modalities, allowing tomographic synchrony of diversified features. PMID:23912256
Elmaleh, D R; Fischman, A J; Tawakol, A; Zhu, A; Shoup, T M; Hoffmann, U; Brownell, A-L; Zamecnik, P C
2006-10-24
Diadenosine-5',5'''-P(1),P(4)-tetraphosphate (Ap(4)A) and its analog P(2),P(3)-monochloromethylene diadenosine-5',5'''-P(1),P(4)-tetraphosphate (AppCHClppA) are competitive inhibitors of adenosine diphosphate-induced platelet aggregation, which plays a central role in arterial thrombosis and plaque formation. In this study, we evaluate the imaging capabilities of positron-emission tomography (PET) with P(2),P(3)-[(18)F]monofluoromethylene diadenosine-5',5'''-P(1),P(4)-tetraphosphate ([(18)F]AppCHFppA) to detect atherosclerotic lesions in male New Zealand White rabbits. Three to six months after balloon injury to the aorta, the rabbits were injected with [(18)F]AppCHFppA, and microPET imaging showed rapid accumulation of this radiopharmaceutical in the atherosclerotic abdominal aorta, with lesions clearly visible 30 min after injection. Computed tomographic images were coregistered with PET images to improve delineation of aortoiliac tracer activity. Plaque macrophage density, quantified by immunostaining with RAM11 against rabbit macrophages, correlated with PET measurements of [(18)F]AppCHFppA uptake (r = 0.87, P < 0.0001), whereas smooth-muscle cell density, quantified by immunostaining with 1A4 against smooth muscle actin, did not. Biodistribution studies of [(18)F]AppCHFppA in normal rats indicated typical adenosine dinucleotide behavior with insignificant myocardial uptake and fast kidney clearance. The accumulation of [(18)F]AppCHFppA in macrophage-rich atherosclerotic plaques can be quantified noninvasively with PET. Hence, [(18)F]AppCHFppA holds promise for the noninvasive characterization of vascular inflammation.
Motion compensation using origin ensembles in awake small animal positron emission tomography
NASA Astrophysics Data System (ADS)
Gillam, John E.; Angelis, Georgios I.; Kyme, Andre Z.; Meikle, Steven R.
2017-02-01
In emission tomographic imaging, the stochastic origin ensembles algorithm provides unique information regarding the detected counts given the measured data. Precision in both voxel and region-wise parameters may be determined for a single data set based on the posterior distribution of the count density allowing uncertainty estimates to be allocated to quantitative measures. Uncertainty estimates are of particular importance in awake animal neurological and behavioral studies for which head motion, unique for each acquired data set, perturbs the measured data. Motion compensation can be conducted when rigid head pose is measured during the scan. However, errors in pose measurements used for compensation can degrade the data and hence quantitative outcomes. In this investigation motion compensation and detector resolution models were incorporated into the basic origin ensembles algorithm and an efficient approach to computation was developed. The approach was validated against maximum liklihood—expectation maximisation and tested using simulated data. The resultant algorithm was then used to analyse quantitative uncertainty in regional activity estimates arising from changes in pose measurement precision. Finally, the posterior covariance acquired from a single data set was used to describe correlations between regions of interest providing information about pose measurement precision that may be useful in system analysis and design. The investigation demonstrates the use of origin ensembles as a powerful framework for evaluating statistical uncertainty of voxel and regional estimates. While in this investigation rigid motion was considered in the context of awake animal PET, the extension to arbitrary motion may provide clinical utility where respiratory or cardiac motion perturb the measured data.
Thomas, Gregory S; Wann, L Samuel; Allam, Adel H; Thompson, Randall C; Michalik, David E; Sutherland, M Linda; Sutherland, James D; Lombardi, Guido P; Watson, Lucia; Cox, Samantha L; Valladolid, Clide M; Abd El-Maksoud, Gomaa; Al-Tohamy Soliman, Muhammad; Badr, Ibrahem; el-Halim Nur el-Din, Abd; Clarke, Emily M; Thomas, Ian G; Miyamoto, Michael I; Kaplan, Hillard S; Frohlich, Bruno; Narula, Jagat; Stewart, Alexandre F R; Zink, Albert; Finch, Caleb E
2014-06-01
Computed tomographic findings of atherosclerosis in the ancient cultures of Egypt, Peru, the American Southwest and the Aleutian Islands challenge our understanding of the fundamental causes of atherosclerosis. Could these findings be true? Is so, what traditional risk factors might be present in these cultures that could explain this apparent paradox? The recent computed tomographic findings are consistent with multiple autopsy studies dating as far back as 1852 that demonstrate calcific atherosclerosis in ancient Egyptians and Peruvians. A nontraditional cause of atherosclerosis that could explain this burden of atherosclerosis is the microbial and parasitic inflammatory burden likely to be present in ancient cultures inherently lacking modern hygiene and antimicrobials. Patients with chronic systemic inflammatory diseases of today, including systemic lupus erythematosus, rheumatoid arthritis, and human immunodeficiency virus infection, experience premature atherosclerosis and coronary events. Might the chronic inflammatory load of ancient times secondary to infection have resulted in atherosclerosis? Smoke inhalation from the use of open fires for daily cooking and illumination represents another potential cause. Undiscovered risk factors could also have been present, potential causes that technologically cannot currently be measured in our serum or other tissue. A synthesis of these findings suggests that a gene-environmental interplay is causal for atherosclerosis. That is, humans have an inherent genetic susceptibility to atherosclerosis, whereas the speed and severity of its development are secondary to known and potentially unknown environmental factors. Copyright © 2014 World Heart Federation (Geneva). Published by Elsevier B.V. All rights reserved.
Washko, George R; Kinney, Gregory L; Ross, James C; San José Estépar, Raúl; Han, MeiLan K; Dransfield, Mark T; Kim, Victor; Hatabu, Hiroto; Come, Carolyn E; Bowler, Russell P; Silverman, Edwin K; Crapo, James; Lynch, David A; Hokanson, John; Diaz, Alejandro A
2017-04-01
Emphysema is characterized by airspace dilation, inflammation, and irregular deposition of elastin and collagen in the interstitium. Computed tomographic studies have reported that lung mass (LM) may be increased in smokers, a finding attributed to inflammatory and parenchymal remodeling processes observed on histopathology. We sought to examine the epidemiologic and clinical associations of LM in smokers. Baseline epidemiologic, clinical, and computed tomography (CT) data (n = 8156) from smokers enrolled into the COPDGene Study were analyzed. LM was calculated from the CT scan. Changes in lung function at 5 years' follow-up were available from 1623 subjects. Regression analysis was performed to assess for associations of LM with forced expiratory volume in 1 second (FEV 1 ) and FEV 1 decline. Subjects with Global Initiative for Chronic Obstructive Lung Disease (GOLD) 1 chronic obstructive pulmonary disease had greater LM than either smokers with normal lung function or those with GOLD 2-4 chronic obstructive pulmonary disease (P < 0.001 for both comparisons). LM was predictive of the rate of the decline in FEV 1 (decline per 100 g, -4.7 ± 1.7 mL/y, P = 0.006). Our cross-sectional data suggest the presence of a biphasic radiological remodeling process in smokers: the presence of such nonlinearity must be accounted for in longitudinal computed tomographic studies. Baseline LM predicts the decline in lung function. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.
Epicardial adipose tissue as a predictor of coronary artery disease in asymptomatic subjects.
Bachar, Gil N; Dicker, Dror; Kornowski, Ran; Atar, Eli
2012-08-15
This study sought to elucidate the relation between epicardial adipose tissue (EAT) thickness measured by multidetector computed tomography and presence of coronary artery atherosclerosis. Recent studies have suggested that fat disposition in visceral organs and epicardial tissue could serve as a predictor of coronary artery disease (CAD). The sample included 190 asymptomatic subjects with ≥ 1 cardiovascular risk factor who were referred for cardiac computed tomographic angiography. Body mass index, blood pressure, fasting glucose level, and lipid profile were measured. Multidetector computed tomographic results were analyzed for atherosclerosis burden, calcium Agatston score, and EAT thickness: mean EAT values were 3.54 ± 1.59 mm in patients with atherosclerosis and 1.85 ± 1.28 mm in patients without atherosclerosis (p <0.001). On receiver operating characteristic analysis, an EAT value ≥ 2.4 mm predicted the presence of significant (>50% diameter) coronary artery stenosis. There was a significant difference in EAT values between patients with and without metabolic syndrome (2.58 ± 1.63 vs 2.04 ± 1.46 mm, p <0.05) and between patients with a calcium score >400 and <400 (3.38 ± 1.58 vs 2.02 ± 1.42 mm, p <0.0001). In conclusion, asymptomatic patients with CAD have significantly more EAT than patients without CAD. An EAT thickness of 2.4 mm is the optimal cutoff for prediction of presence of significant CAD. Copyright © 2012 Elsevier Inc. All rights reserved.
Quantification of Methane Source Locations and Emissions in AN Urban Setting
NASA Astrophysics Data System (ADS)
Crosson, E.; Richardson, S.; Tan, S. M.; Whetstone, J.; Bova, T.; Prasad, K. R.; Davis, K. J.; Phillips, N. G.; Turnbull, J. C.; Shepson, P. B.; Cambaliza, M. L.
2011-12-01
The regulation of methane emissions from urban sources such as landfills and waste-water treatment facilities is currently a highly debated topic in the US and in Europe. This interest is fueled, in part, by recent measurements indicating that urban emissions are a significant source of Methane (CH4) and in fact may be substantially higher than current inventory estimates(1). As a result, developing methods for locating and quantifying emissions from urban methane sources is of great interest to industries such as landfill and wastewater treatment facility owners, watchdog groups, and the governmental agencies seeking to evaluate or enforce regulations. In an attempt to identify major methane source locations and emissions in Boston, Indianapolis, and the Bay Area, systematic measurements of CH4 concentrations and meteorology data were made at street level using a vehicle mounted cavity ringdown analyzer. A number of discrete sources were detected at concentration levels in excess of 15 times background levels. Using Gaussian plume models as well as tomographic techniques, methane source locations and emission rates will be presented. In addition, flux chamber measurements of discrete sources such as those found in natural gas leaks will also be presented. (1) Wunch, D., P.O. Wennberg, G.C. Toon, G. Keppel-Aleks, and Y.G. Yavin, Emissions of Greenhouse Gases from a North American Megacity, Geophysical Research Letters, Vol. 36, L15810, doi:10.1029/2009GL)39825, 2009.
Brucella pelvic tubo-ovarian abscess mimicking a pelvic malignancy.
Seoud, Muhiedine A F; Kanj, Suha S; Habli, Munira; Araj, George F; Khalil, Ali M
2003-01-01
A 57-y-old woman presented with recurrent abdominal and pelvic pain of 6 months' duration with low-grade fever. A computed tomographic scan indicated an ovarian tumor. Laparotomy revealed a pelvic abscess. Her symptoms resolved following surgery and antibiotic therapy. Pathology revealed an extensive inflammatory process. Tissue culture grew Brucella sp. The diagnosis and management of this previously undescribed pelvic tubo-ovarian abscess present a particular challenge.
Chest CT window settings with multiscale adaptive histogram equalization: pilot study.
Fayad, Laura M; Jin, Yinpeng; Laine, Andrew F; Berkmen, Yahya M; Pearson, Gregory D; Freedman, Benjamin; Van Heertum, Ronald
2002-06-01
Multiscale adaptive histogram equalization (MAHE), a wavelet-based algorithm, was investigated as a method of automatic simultaneous display of the full dynamic contrast range of a computed tomographic image. Interpretation times were significantly lower for MAHE-enhanced images compared with those for conventionally displayed images. Diagnostic accuracy, however, was insufficient in this pilot study to allow recommendation of MAHE as a replacement for conventional window display.
Introduction to Seismic Tomography
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rowe, Charlotte Anne
2017-11-21
Tomography is a method of obtaining an image of a 3d object by observing the behavior of energy transmissions through the object. The image is obtained by Interrogating the object with Energy sources at a variety of Locations and observing the Object’s effects on the energy at a Variety of sensors. Tomography was first Used to build 3-dimensional Scans through Human bodies. These Are called computed Tomographic (ct) scans.
Computed tomographic findings in 44 dogs and 10 cats with grass seed foreign bodies.
Vansteenkiste, D P; Lee, K C L; Lamb, C R
2014-11-01
To supplement recent reports of computed tomographic (CT) findings in dogs and cats with grass seed foreign bodies. Retrospective review of cases that had CT scan and subsequent retrieval of a grass seed during the same period of hospitalisation from a site included in the scan. Records of 44 dogs and 10 cats were reviewed. Most were presented in the months July to December. Median duration of clinical signs was 4 weeks (range 2 days to 2 years). The most frequent clinical signs were soft tissue swelling (30% cases), coughing (28%), sneezing (28%) and discharge (26%). Grass seeds were retrieved from the thorax (35% cases), nasal cavity (31%), ear (7%), other sites in the head and neck (22%), sublumbar muscles (2%) and pelvic limb (2%). The grass seed was visible in CT images in 10 (19%) cases. Secondary lesions were visible in CT images of 52 (96%) cases, including collection of exudate (37%), abscess (24%), enlarged lymph nodes (22%) and pulmonary consolidation (20%). CT images appeared normal in 4% animals. Grass seeds within the respiratory tract are frequently visible in CT images, but in general CT appears to be more useful for localisation of secondary lesions than as a method of definite diagnosis. © 2014 British Small Animal Veterinary Association.
Yang, Tao; Gu, Yongchun; Zhang, Li; Hua, Zequan
2014-03-01
We report a rare case of congenital tri-cavernous hemangiomas of the right buccal region, right accessory parotid gland, and masseter muscle region in an adult. The patient, a 25-year-old woman, complained of 3 masses in her right midcheek. Ultrasonographic and computed tomographic findings showed an irregular-shaped mass (multiple calcifications) with a well-defined margin in the masseter muscle region, an ellipse-shaped mass (multiple calcifications) with a well-defined margin in the right buccal region, and a comma-shaped mass (no calcifications) with a well-defined margin separate from the parotid gland in the right accessory parotid gland region. These iconographic findings suggested that the masses were all hemangiomas separately originating from the parotid gland, accessory parotid gland, and masseter muscle. The masses were completely removed through a standard parotid incision without postoperative facial palsy, skin deformity, and difficulty in secreting saliva. Findings from histologic examination of the tumor revealed multiple, thin-walled, and dilated blood vessels, confirming the diagnosis of cavernous hemangiomas. Ultrasonographic and computed tomographic findings were extremely useful in diagnosing the mass/masses as hemangioma before surgery, clarifying relationships between the mass and adjacent structures, and determining the surgical approach to the mass/masses.
Noninvasive coronary artery angiography using electron beam computed tomography
NASA Astrophysics Data System (ADS)
Rumberger, John A.; Rensing, Benno J.; Reed, Judd E.; Ritman, Erik L.; Sheedy, Patrick F., II
1996-04-01
Electron beam computed tomography (EBCT), also known as ultrafast-CT or cine-CT, uses a unique scanning architecture which allows for multiple high spatial resolution electrocardiographic triggered images of the beating heart. A recent study has demonstrated the feasibility of qualitative comparisons between EBCT derived 3D coronary angiograms and invasive angiography. Stenoses of the proximal portions of the left anterior descending and right coronary arteries were readily identified, but description of atherosclerotic narrowing in the left circumflex artery (and distal epicardial disease) was not possible with any degree of confidence. Although these preliminary studies support the notion that this approach has potential, the images overall were suboptimal for clinical application as an adjunct to invasive angiography. Furthermore, these studies did not examine different methods of EBCT scan acquisition, tomographic slice thicknesses, extent of scan overlap, or other segmentation, thresholding, and interpolation algorithms. Our laboratory has initiated investigation of these aspects and limitations of EBCT coronary angiography. Specific areas of research include defining effects of cardiac orientation; defining the effects of tomographic slice thickness and intensity (gradient) versus positional (shaped based) interpolation; and defining applicability of imaging each of the major epicardial coronary arteries for quantitative definition of vessel size, cross-sectional area, taper, and discrete vessel narrowing.
A synchrotron radiation microtomography system for the analysis of trabecular bone samples.
Salomé, M; Peyrin, F; Cloetens, P; Odet, C; Laval-Jeantet, A M; Baruchel, J; Spanne, P
1999-10-01
X-ray computed microtomography is particularly well suited for studying trabecular bone architecture, which requires three-dimensional (3-D) images with high spatial resolution. For this purpose, we describe a three-dimensional computed microtomography (microCT) system using synchrotron radiation, developed at ESRF. Since synchrotron radiation provides a monochromatic and high photon flux x-ray beam, it allows high resolution and a high signal-to-noise ratio imaging. The principle of the system is based on truly three-dimensional parallel tomographic acquisition. It uses a two-dimensional (2-D) CCD-based detector to record 2-D radiographs of the transmitted beam through the sample under different angles of view. The 3-D tomographic reconstruction, performed by an exact 3-D filtered backprojection algorithm, yields 3-D images with cubic voxels. The spatial resolution of the detector was experimentally measured. For the application to bone investigation, the voxel size was set to 6.65 microm, and the experimental spatial resolution was found to be 11 microm. The reconstructed linear attenuation coefficient was calibrated from hydroxyapatite phantoms. Image processing tools are being developed to extract structural parameters quantifying trabecular bone architecture from the 3-D microCT images. First results on human trabecular bone samples are presented.
McAllister, E; Perez, M; Albrink, M H; Olsen, S M; Rosemurgy, A S
1994-09-01
We devised a protocol to prospectively manage stab wounds to the back with the hypothesis that the triple contrast computed tomographic (CT) scan is an effective means of detecting occult injury in these patients. All wounds to the back in hemodynamically stable adults were locally explored. All patients with muscular fascial penetration underwent triple contrast CT scanning utilizing oral, rectal, and IV contrast. Patients did not undergo surgical exploration if their CT scan was interpreted as negative or if the CT scan demonstrated injuries not requiring surgical intervention. Fifty-three patients were entered into the protocol. The time to complete the triple contrast CT scan ranged from 3 to 6 hours at a cost of $1050 for each scan. In 51 patients (96%), the CT scan either had negative findings (n = 31) or showed injuries not requiring exploration (n = 20). These patients did well with nonsurgical management. Two CT scans documented significant injury and led to surgical exploration and therapeutic celiotomies. Although triple contrast CT scanning was able to detect occult injury in patients with stab wounds to the back it did so at considerable cost and the results rarely altered clinical care. Therefore, its routine use in these patients is not recommended.
Microendoscopic excision of C2 osteoid osteoma: a technical report.
Kulkarni, Arvind G; Dhruv, Abhilash N; Bassi, Anupreet J
2013-09-01
Case report and description of technique. To describe a microendoscopic posterior approach for excision of an osteoid osteoma of C2. Microendoscopic techniques are widely used in the management of degenerative disorders of the spine. This is the first report of their use in the management of an osteoid osteoma via the posterior approach. A 12-year-old-boy presented with left-sided neck pain of 3-month duration. Investigations revealed an osteoid osteoma of C2 lamina-lateral mass complex. The patient underwent a posterior microendoscopic excision using 18-mm diameter METRx system (Medtronic Sofamor Danek, Memphis, TN) of tubular retractors. A postoperative computed tomographic scan was done and preoperative and postoperative visual analogue scale and Neck Disability Index were evaluated. The patient was periodically followed up for 1 year. The postoperative computed tomographic scan revealed complete excision of the tumor. The visual analogue scale score for neck pain improved from 3/5 (preoperative) to 0/5 (postoperative) and Neck Disability Index from 33.33 (preoperative) to 0 (postoperative) at 1-year follow-up. Microendoscopic techniques can be extended to excise lesions of the spine. It is a safe procedure in experienced hands. The advantages are minimal morbidity, minimal postoperative pain and discomfort, less analgesic dependence, and better cosmesis. The authors recommend this technique for accessible lesions involving the spine.
Teymouri, Jessica; Hullar, Timothy E; Holden, Timothy A; Chole, Richard A
2011-08-01
To determine the efficacy of clinical computed tomographic (CT) imaging to verify postoperative electrode array placement in cochlear implant (CI) patients. Nine fresh cadaver heads underwent clinical CT scanning, followed by bilateral CI insertion and postoperative clinical CT scanning. Temporal bones were removed, trimmed, and scanned using micro-CT. Specimens were then dehydrated, embedded in either methyl methacrylate or LR White resin, and sectioned with a diamond wafering saw. Histology sections were examined by 3 blinded observers to determine the position of individual electrodes relative to soft tissue structures within the cochlea. Electrodes were judged to be within the scala tympani, scala vestibuli, or in an intermediate position between scalae. The position of the array could be estimated accurately from clinical CT scans in all specimens using micro-CT and histology as a criterion standard. Verification using micro-CT yielded 97% agreement, and histologic analysis revealed 95% agreement with clinical CT results. A composite, 3-dimensional image derived from a patient's preoperative and postoperative CT images using a clinical scanner accurately estimates the position of the electrode array as determined by micro-CT imaging and histologic analyses. Information obtained using the CT method provides valuable insight into numerous variables of interest to patient performance such as surgical technique, array design, and processor programming and troubleshooting.
Agarwal, Nitin; Biancardi, Alberto M; Patten, Florence W; Reeves, Anthony P; Seibel, Eric J
2014-04-01
Aneuploidy is typically assessed by flow cytometry (FCM) and image cytometry (ICM). We used optical projection tomographic microscopy (OPTM) for assessing cellular DNA content using absorption and fluorescence stains. OPTM combines some of the attributes of both FCM and ICM and generates isometric high-resolution three-dimensional (3-D) images of single cells. Although the depth of field of the microscope objective was in the submicron range, it was extended by scanning the objective's focal plane. The extended depth of field image is similar to a projection in a conventional x-ray computed tomography. These projections were later reconstructed using computed tomography methods to form a 3-D image. We also present an automated method for 3-D nuclear segmentation. Nuclei of chicken, trout, and triploid trout erythrocyte were used to calibrate OPTM. Ratios of integrated optical densities extracted from 50 images of each standard were compared to ratios of DNA indices from FCM. A comparison of mean square errors with thionin, hematoxylin, Feulgen, and SYTOX green was done. Feulgen technique was preferred as it showed highest stoichiometry, least variance, and preserved nuclear morphology in 3-D. The addition of this quantitative biomarker could further strengthen existing classifiers and improve early diagnosis of cancer using 3-D microscopy.
Computed tomographic imaging of stapes implants.
Warren, Frank M; Riggs, Sterling; Wiggins, Richard H
2008-08-01
Computed tomographic (CT) imaging of stapes prostheses is inaccurate. Clinical situations arise in which it would be helpful to determine the depth of penetration of a stapes prosthesis into the vestibule. The accuracy of CT imaging for this purpose has not been defined. This study was aimed to determine the accuracy of CT imaging to predict the depth of intrusion of stapes prostheses into the vestibule. The measurement of stapes prostheses by CT scan was compared with physical measurements in 8 cadaveric temporal bones. The depth of intrusion into the vestibule of the piston was underestimated in specimens with the fluoroplastic piston by a mean of 0.5 mm when compared with the measurements obtained in the temporal bones. The depth of penetration of the stainless steel implant was overestimated by 0.5 mm when compared with that in the temporal bone. The type of implant must be taken into consideration when estimating the depth of penetration into the vestibule using CT scanning because the imaging characteristics of the implanted materials differ. The position of fluoroplastic pistons cannot be accurately measured in the vestibule. Metallic implants are well visualized, and measurements exceeding 2.2 mm increase the suspicion of otolithic impingement. Special reconstructions along the length of the piston may be more accurate in estimating the position of stapes implants.
Cone Beam Computed Tomographic imaging in orthodontics.
Scarfe, W C; Azevedo, B; Toghyani, S; Farman, A G
2017-03-01
Over the last 15 years, cone beam computed tomographic (CBCT) imaging has emerged as an important supplemental radiographic technique for orthodontic diagnosis and treatment planning, especially in situations which require an understanding of the complex anatomic relationships and surrounding structures of the maxillofacial skeleton. CBCT imaging provides unique features and advantages to enhance orthodontic practice over conventional extraoral radiographic imaging. While it is the responsibility of each practitioner to make a decision, in tandem with the patient/family, consensus-derived, evidence-based clinical guidelines are available to assist the clinician in the decision-making process. Specific recommendations provide selection guidance based on variables such as phase of treatment, clinically-assessed treatment difficulty, the presence of dental and/or skeletal modifying conditions, and pathology. CBCT imaging in orthodontics should always be considered wisely as children have conservatively, on average, a three to five times greater radiation risk compared with adults for the same exposure. The purpose of this paper is to provide an understanding of the operation of CBCT equipment as it relates to image quality and dose, highlight the benefits of the technique in orthodontic practice, and provide guidance on appropriate clinical use with respect to radiation dose and relative risk, particularly for the paediatric patient. © 2017 Australian Dental Association.
Diagnostic performance of 64-slice multidetector coronary computed tomographic angiography in women.
Jug, Borut; Gupta, Mohit; Papazian, Jenny; Li, Dong; Tsang, Janet; Bhatia, Harpreet; Karlsberg, Ronald; Budoff, Matthew
2012-12-01
Diagnostic approach to chest pain in women is challenging, but still under-investigated. The purpose of this study was to assess the diagnostic performance of 64-slice multidetector coronary computed tomographic angiography (CCTA) in women with chest pain. We included 606 patients--255 women and 351 men (mean age 61 ± 12 years for both)--who had been referred for a CCTA and an invasive coronary angiography (diagnostic standard) because of chest pain, either as part of clinical work-up in two urban medical centers or as part of the multicenter ACCURACY trial. On a patient-based model, the sensitivity, specificity, and positive predictive value (PPV) and negative predictive value to detect ≥50% and ≥70% stenosis were 98%, 84%, 87%, and 97% and 96%, 83%, 77%, and 97%, respectively, for women and 97%, 83%, 89%, and 95% and 94%, 91%, 90%, and 94%, respectively, for men. There were no statistically significant differences between men and women in diagnostic performance measures except for the PPV of detecting a ≥70% stenosis (P = .007). In women with chest pain, 64-slice multidetector CCTA is at least as sensitive and specific as in men. Our findings suggest that CCTA is a promising diagnostic tool for timely detection and/or exclusion of CAD in symptomatic intermediate-risk female populations.
Evolution of cystic fibrosis lung function in the early years.
Bush, Andrew; Sly, Peter D
2015-11-01
Most treatment of newborn screening-diagnosed cystic fibrosis is not evidence-based; there are very few randomized controlled trials (RCTs). Furthermore, the advent of novel molecular therapies, which could be started at diagnosis, mandates performing RCTs in very young children. However, unless the natural history of early cystic fibrosis lung disease is known, RCTs are impossible. Here, we review the results of two large prospective cohorts of these infants - London Cystic Fibrosis Collaboration (LCFC) (London, UK) and Australian Respiratory Early Surveillance Team for Cystic Fibrosis (AREST-CF) (Australia). Nutritional status remained excellent in both the cohorts. Both cohorts reported abnormal lung function aged at 3 months. AREST-CF, which previously reported rapidly declining preschool lung function, now report good conventional school-age spirometry. LCFC reported improvement between 3 months and 1 year, and stability in the second year. AREST-CF also reported a high prevalence of high resolution computed tomographic abnormalities related to free neutrophil elastase in bronchoalveolar lavage; LCFC reported high resolution computed tomographic changes at 1 year, which were too mild to be scored reproducibly. At least in the first 2 years of life, lung function is not a good end-point for RCTs; routine bronchoalveolar lavage and HRCT cannot be justified. Newborn screening has greatly improved outcomes, but we need better point-of-care biomarkers.
Liisanantti, Janne Henrik; Ala-Kokko, Tero Ilmari
2015-12-01
The present study was conducted to explore the impact of computed tomographic (CT) scanning on the diagnostic discrepancy rate. This single-center, retrospective study reviewed postmortem examination results, clinical diagnoses, and radiologic imaging data for patients admitted to the intensive care unit (ICU) in 2008 to 2013. The Goldman criteria were used to classify diagnostic discrepancies. The data of 577 patients who died during their ICU stay were retrieved. The postmortem examination rate was 42.9% (n=248). Significant diagnostic discrepancies (Goldman I and II) were recorded in 24 cases (9.7%). The postmortem examination rate decreased significantly from the first half (n=143; 51.1%) to the second half (n=105; 35.4%) of the study period (P<.0001). Among those with postmortem examinations, the use of antemortem body CT scans increased significantly from the first half (n=59; 41.3%) to the second half (n=64; 51.0%; P=.002) of the study period. The significant diagnostic discrepancy rate did not change with time (8.4% vs 11.4%, respectively; P=.424). The postmortem examination rate has decreased, whereas antemortem CT scans has increased. Copyright © 2015 Elsevier Inc. All rights reserved.
Computer-aided detection of initial polyp candidates with level set-based adaptive convolution
NASA Astrophysics Data System (ADS)
Zhu, Hongbin; Duan, Chaijie; Liang, Zhengrong
2009-02-01
In order to eliminate or weaken the interference between different topological structures on the colon wall, adaptive and normalized convolution methods were used to compute the first and second order spatial derivatives of computed tomographic colonography images, which is the beginning of various geometric analyses. However, the performance of such methods greatly depends on the single-layer representation of the colon wall, which is called the starting layer (SL) in the following text. In this paper, we introduce a level set-based adaptive convolution (LSAC) method to compute the spatial derivatives, in which the level set method is employed to determine a more reasonable SL. The LSAC was applied to a computer-aided detection (CAD) scheme to detect the initial polyp candidates, and experiments showed that it benefits the CAD scheme in both the detection sensitivity and specificity as compared to our previous work.
Building a symbolic computer algebra toolbox to compute 2D Fourier transforms in polar coordinates
Dovlo, Edem; Baddour, Natalie
2015-01-01
The development of a symbolic computer algebra toolbox for the computation of two dimensional (2D) Fourier transforms in polar coordinates is presented. Multidimensional Fourier transforms are widely used in image processing, tomographic reconstructions and in fact any application that requires a multidimensional convolution. By examining a function in the frequency domain, additional information and insights may be obtained. The advantages of our method include: • The implementation of the 2D Fourier transform in polar coordinates within the toolbox via the combination of two significantly simpler transforms. • The modular approach along with the idea of lookup tables implemented help avoid the issue of indeterminate results which may occur when attempting to directly evaluate the transform. • The concept also helps prevent unnecessary computation of already known transforms thereby saving memory and processing time. PMID:26150988
Computed intraoperative navigation guidance--a preliminary report on a new technique.
Enislidis, G; Wagner, A; Ploder, O; Ewers, R
1997-08-01
To assess the value of a computer-assisted three-dimensional guidance system (Virtual Patient System) in maxillofacial operations. Laboratory and open clinical study. Teaching Hospital, Austria. 6 patients undergoing various procedures including removal of foreign body (n=3) and biopsy, maxillary advancement, and insertion of implants (n=1 each). Storage of computed tomographic (CT) pictures on an optical disc, and imposition of intraoperative video images on to these. The resulting display is shown to the surgeon on a micromonitor in his head-up display for guidance during the operations. To improve orientation during complex or minimally invasive maxillofacial procedures and to make such operations easier and less traumatic. Successful transferral of computed navigation technology into an operation room environment and positive evaluation of the method by the surgeons involved. Computer-assisted three-dimensional guidance systems have the potential for making complex or minimally invasive procedures easier to do, thereby reducing postoperative morbidity.
Seismic imaging: From classical to adjoint tomography
NASA Astrophysics Data System (ADS)
Liu, Q.; Gu, Y. J.
2012-09-01
Seismic tomography has been a vital tool in probing the Earth's internal structure and enhancing our knowledge of dynamical processes in the Earth's crust and mantle. While various tomographic techniques differ in data types utilized (e.g., body vs. surface waves), data sensitivity (ray vs. finite-frequency approximations), and choices of model parameterization and regularization, most global mantle tomographic models agree well at long wavelengths, owing to the presence and typical dimensions of cold subducted oceanic lithospheres and hot, ascending mantle plumes (e.g., in central Pacific and Africa). Structures at relatively small length scales remain controversial, though, as will be discussed in this paper, they are becoming increasingly resolvable with the fast expanding global and regional seismic networks and improved forward modeling and inversion techniques. This review paper aims to provide an overview of classical tomography methods, key debates pertaining to the resolution of mantle tomographic models, as well as to highlight recent theoretical and computational advances in forward-modeling methods that spearheaded the developments in accurate computation of sensitivity kernels and adjoint tomography. The first part of the paper is devoted to traditional traveltime and waveform tomography. While these approaches established a firm foundation for global and regional seismic tomography, data coverage and the use of approximate sensitivity kernels remained as key limiting factors in the resolution of the targeted structures. In comparison to classical tomography, adjoint tomography takes advantage of full 3D numerical simulations in forward modeling and, in many ways, revolutionizes the seismic imaging of heterogeneous structures with strong velocity contrasts. For this reason, this review provides details of the implementation, resolution and potential challenges of adjoint tomography. Further discussions of techniques that are presently popular in seismic array analysis, such as noise correlation functions, receiver functions, inverse scattering imaging, and the adaptation of adjoint tomography to these different datasets highlight the promising future of seismic tomography.
NASA Astrophysics Data System (ADS)
Seidel, Anne; Wagner, Steven; Dreizler, Andreas; Ebert, Volker
2014-05-01
One of the most intricate effects in climate modelling is the role of permafrost thawing during the global warming process. Soil that has formerly never totally lost its ice cover now emits climate gases due to melting processes[1]. For a better prediction of climate development and possible feedback mechanisms, insights into physical procedures (like e.g. gas emission from underground reservoirs) are required[2]. Therefore, a long-term quantification of greenhouse gas concentrations (and further on fluxes) is necessary and the related structures that are responsible for emission need to be identified. In particular the spatial heterogeneity of soils caused by soil internal structures (e.g. soil composition changes or surface cracks) or by surface modifications (e.g. by plant growth) generate considerable complexities and difficulties for local measurements, for example with soil chambers. For such situations, which often cannot be avoided, a spatially resolved 2D-measurement to identify and quantify the gas emission from the structured soil would be needed, to better understand the influence of the soil sub-structures on the emission behavior. Thus we designed a spatially scanning laser absorption spectrometer setup to determine a 2D-gas concentration map in the soil-air boundary layer. The setup is designed to cover the surfaces in the range of square meters in a horizontal plane above the soil to be investigated. Existing field instruments for gas concentration or flux measurements are based on point-wise measurements, so structure identification is very tedious or even impossible. For this reason, we have developed a tomographic in-situ instrument based on TDLAS ('tunable diode laser absorption spectroscopy') that delivers absolute gas concentration distributions of areas with 0.8m × 0.8m size, without any need for reference measurements with a calibration gas. It is a simple and robust device based on a combination of scanning mirrors and reflecting foils, so that only very little optical alignment is necessary in the field. The measurement rate for a complete 2D field is presently up to 2.5 Hz. The measurement field size is currently limited only by laboratory conditions and could be extended easily to the range of several meters, as previous tests have confirmed[3]. A fast laser tuning rate of more than 5 kHz leads to high measurement path density, and overall more than 70% of a square shaped field area is covered. With this instrument, measurements of H2O- and CH4 - concentration distributions have taken place so far. We are going to discuss the instrument setup and the spectroscopic performance and present numerical studies concerning the tomographic reconstruction quality as well as first 2D reconstructions in the laboratory. The applicability to 2D CO2 detection and the improvement of frame rate and reconstruction quality using faster laser tuning will be discussed. [1] K. M. Walter Anthony, P. Anthony, G. Grosse, and J. Chanton, 'Geologic methane seeps along boundaries of Arctic permafrost thaw and melting glaciers,' Nat. Geosci., vol. 5, no. 6, pp. 419-426, May 2012. [2] B. Elberling, A. Michelsen, C. Schädel, E. A. G. Schuur, H. H. Christiansen, L. Tamstorf, M. P. Berg, and C. Sigsgaard, 'Long-term CO2 production following permafrost thaw,' Nat. Clim. Chang., vol. 3, no. 10, pp. 890-894, 2013. [3] A. Seidel, S. Wagner, and V. Ebert, 'TDLAS-based open-path laser hygrometer using simple reflective foils as scattering targets,' Appl. Phys. B, vol. 109, no. 3, pp. 497-504, Oct. 2012.
Abbara, Suhny; Blanke, Philipp; Maroules, Christopher D; Cheezum, Michael; Choi, Andrew D; Han, B Kelly; Marwan, Mohamed; Naoum, Chris; Norgaard, Bjarne L; Rubinshtein, Ronen; Schoenhagen, Paul; Villines, Todd; Leipsic, Jonathon
In response to recent technological advancements in acquisition techniques as well as a growing body of evidence regarding the optimal performance of coronary computed tomography angiography (coronary CTA), the Society of Cardiovascular Computed Tomography Guidelines Committee has produced this update to its previously established 2009 "Guidelines for the Performance of Coronary CTA" (1). The purpose of this document is to provide standards meant to ensure reliable practice methods and quality outcomes based on the best available data in order to improve the diagnostic care of patients. Society of Cardiovascular Computed Tomography Guidelines for the Interpretation is published separately (2). The Society of Cardiovascular Computed Tomography Guidelines Committee ensures compliance with all existing standards for the declaration of conflict of interest by all authors and reviewers for the purpose ofclarity and transparency. Copyright © 2016 Society of Cardiovascular Computed Tomography. All rights reserved.
Florid cemento-osseous dysplasia: A rare case report evaluated with cone-beam computed tomography.
Yildirim, Eren; Bağlar, Serdar; Ciftci, Mehmet Ertugrul; Ozcan, Erdal
2016-01-01
A 29-year-old systemically healthy female patient presented to our department. Cone-beam computed tomographic images showed multiple well-defined sclerotic masses with radiolucent border in both right and left molar regions of the mandible. These sclerotic masses were surrounded by a thin radiolucent border. We diagnosed the present pathology as florid cemento-osseous dysplasia and decided to follow the patient without taking biopsy. For the patient, who did not have any clinical complaints, radiographic followupis recommended twice a year. The responsibility of the dentist is to ensure the follow-up of the diagnosed patients and take necessary measures for preventing the infections.
NASA Astrophysics Data System (ADS)
Zou, C.; Marrow, T. J.; Reinhard, C.; Li, B.; Zhang, C.; Wang, S.
2016-03-01
The pore structure and porosity of a continuous fiber reinforced ceramic matrix composite has been characterized using high-resolution synchrotron X-ray computed tomography (XCT). Segmentation of the reconstructed tomograph images reveals different types of pores within the composite, the inter-fiber bundle open pores displaying a "node-bond" geometry, and the intra-fiber bundle isolated micropores showing a piping shape. The 3D morphology of the pores is resolved and each pore is labeled. The quantitative filtering of the pores measures a total porosity 8.9% for the composite, amid which there is about 7.1~ 9.3% closed micropores.
Assessment of Severity of Ovine Smoke Inhalation Injury by Analysis of Computed Tomographic Scans
2003-09-01
Computerized analysis of three- dimensional reconstructed scans was also performed, based on Hounsfield unit ranges: hyperinflated, 1,000 to 900; normal...the interactive segmentation function of the software. The pulmonary parenchyma was separated into four regions based on the Hounsfield unit (HU...SII) severity. Methods: Twenty anesthetized sheep underwent graded SII: group I, no smoke; group II, 5 smoke units ; group III, 10 units ; and group IV
Pulmonary gangrene as a complication of mucormycosis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zagoria, R.J.; Choplin, R.H.; Karstaedt, N.
1985-06-01
Pulmonary gangrene, a rare complication of pneumonia occurs when vascular thrombosis leads to necrosis of a large portion of lung. The devitalized lung is then sloughed into a cavity, resulting in a characteristic radiographic appearance. The previously reported cases of pulmonary gangrene have been associated with either bacterial or tuberculous pneumonia; the authors describe a case resulting from mucormycosis. In addition to the plain-film findings, the computed tomographic (CT) appearance is described.
Design and initial performance of PlanTIS: a high-resolution positron emission tomograph for plants
NASA Astrophysics Data System (ADS)
Beer, S.; Streun, M.; Hombach, T.; Buehler, J.; Jahnke, S.; Khodaverdi, M.; Larue, H.; Minwuyelet, S.; Parl, C.; Roeb, G.; Schurr, U.; Ziemons, K.
2010-02-01
Positron emitters such as 11C, 13N and 18F and their labelled compounds are widely used in clinical diagnosis and animal studies, but can also be used to study metabolic and physiological functions in plants dynamically and in vivo. A very particular tracer molecule is 11CO2 since it can be applied to a leaf as a gas. We have developed a Plant Tomographic Imaging System (PlanTIS), a high-resolution PET scanner for plant studies. Detectors, front-end electronics and data acquisition architecture of the scanner are based on the ClearPET™ system. The detectors consist of LSO and LuYAP crystals in phoswich configuration which are coupled to position-sensitive photomultiplier tubes. Signals are continuously sampled by free running ADCs, and data are stored in a list mode format. The detectors are arranged in a horizontal plane to allow the plants to be measured in the natural upright position. Two groups of four detector modules stand face-to-face and rotate around the field-of-view. This special system geometry requires dedicated image reconstruction and normalization procedures. We present the initial performance of the detector system and first phantom and plant measurements.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lassen, N.A.; Henriksen, L.; Holm, S.
1983-01-01
Tomographic maps of local cerebral blood flow (CBF) were obtained with xenon-133 and with isopropyl-amphetamine-iodine-123 (IMP) in 11 subjects: one normal, two tumor cases, and eight cerebrovascular cases. A highly sensitive four-face, rapidly rotating, single-photon emission tomograph was used. The Xe-133 flow maps are essentially based on the average Xe-133 concentration over the initial 2 min during and after an inhalation of the inert gas lasting 1 min. These maps agreed very well with the early IMP maps obtained over the initial 10 min following an i.v. bolus injection. The subsequent IMP tomograms showed a slight decrease in contrast amountingmore » to appr. five percentage points in the CBF ratio between diseased and contralateral areas. It is concluded that Xe-133 is more practical: low cost, available on a 7-day basis, easily repeatable, quantifiable without the need for arterial sampling, and with low radiation exposure to patient and personnel. On the other hand, IMP gives an image of slightly higher resolution. It also introduces a new class of iodinated brain-seeking compounds allowing, perhaps, imaging of other functions more important than mere blood flow.« less
Design and initial performance of PlanTIS: a high-resolution positron emission tomograph for plants.
Beer, S; Streun, M; Hombach, T; Buehler, J; Jahnke, S; Khodaverdi, M; Larue, H; Minwuyelet, S; Parl, C; Roeb, G; Schurr, U; Ziemons, K
2010-02-07
Positron emitters such as (11)C, (13)N and (18)F and their labelled compounds are widely used in clinical diagnosis and animal studies, but can also be used to study metabolic and physiological functions in plants dynamically and in vivo. A very particular tracer molecule is (11)CO(2) since it can be applied to a leaf as a gas. We have developed a Plant Tomographic Imaging System (PlanTIS), a high-resolution PET scanner for plant studies. Detectors, front-end electronics and data acquisition architecture of the scanner are based on the ClearPET system. The detectors consist of LSO and LuYAP crystals in phoswich configuration which are coupled to position-sensitive photomultiplier tubes. Signals are continuously sampled by free running ADCs, and data are stored in a list mode format. The detectors are arranged in a horizontal plane to allow the plants to be measured in the natural upright position. Two groups of four detector modules stand face-to-face and rotate around the field-of-view. This special system geometry requires dedicated image reconstruction and normalization procedures. We present the initial performance of the detector system and first phantom and plant measurements.
Transmyocardial revascularization on canine with Ho:YAG laser - an experimental study
NASA Astrophysics Data System (ADS)
Bao, Xiaoqing; Zhu, Jing; Zhang, Hui-Guo
2005-07-01
Background and Objective: To evaluate the efficiency of transmyocardial revascularization with Ho:YAG laser and find out adequate physical parameters of the laser. Materials and Methods: 10 dogs were studied. All the samples were divided into two groups: the laser group (5 dogs) and the control group (5 dogs). Acute myocardial ischemia was induced in all the samples, and transmyocardial laser revascularization (TMLR) was only done in the laser group. We compared the difference of improvement in myocardial perfusion between the two groups with single photon emission computed tomograph (SPECT) and observed the patency of the laser channels and heat injures in the tissue adjacent to the channels with light- and electro-scope. Results: After 4 weeks, the recovery of myocardial perfusion was significantly faster in the laser group than in the control group through SPECT (P<0.05). Most of the laser channels drilled with Ho:YAG laser were filled with fibrin. There were amount of microvessels and erythrocytes inside and around the channels. Only slight heat injures were seen in the tissue adjacent to the channels. Only 20-30 watts were needed in TMLR. Conclusions: Transmyocardial revascularization with Ho:YAG laser limits infarct expansion and reduces myocardial ischemia efficiently. TMLR with Ho:YAG laser can become a new technique to treat ischemic heart disease.
NASA Astrophysics Data System (ADS)
Faber, Tracy L.; Garcia, Ernest V.; Lalush, David S.; Segars, W. Paul; Tsui, Benjamin M.
2001-05-01
The spline-based Mathematical Cardiac Torso (MCAT) phantom is a realistic software simulation designed to simulate single photon emission computed tomographic (SPECT) data. It incorporates a heart model of known size and shape; thus, it is invaluable for measuring accuracy of acquisition, reconstruction, and post-processing routines. New functionality has been added by replacing the standard heart model with left ventricular (LV) epicaridal and endocardial surface points detected from actual patient SPECT perfusion studies. LV surfaces detected from standard post-processing quantitation programs are converted through interpolation in space and time into new B-spline models. Perfusion abnormalities are added to the model based on results of standard perfusion quantification. The new LV is translated and rotated to fit within existing atria and right ventricular models, which are scaled based on the size of the LV. Simulations were created for five different patients with myocardial infractions who had undergone SPECT perfusion imaging. Shape, size, and motion of the resulting activity map were compared visually to the original SPECT images. In all cases, size, shape and motion of simulated LVs matched well with the original images. Thus, realistic simulations with known physiologic and functional parameters can be created for evaluating efficacy of processing algorithms.