Sample records for emission screening test

  1. Outcomes of transient evoked otoacoustic emission testing in 6-year-old school children: a comparison with pure tone screening and tympanometry.

    PubMed

    Driscoll, C; Kei, J; McPherson, B

    2001-01-01

    (1) To establish test performance measures for Transient Evoked Otoacoustic Emission testing of 6-year-old children in a school setting; (2) To investigate whether Transient Evoked Otoacoustic Emission testing provides a more accurate and effective alternative to a pure tone screening plus tympanometry protocol. Pure tone screening, tympanometry and transient evoked otoacoustic emission data were collected from 940 subjects (1880 ears), with a mean age of 6.2 years. Subjects were tested in non-sound-treated rooms within 22 schools. Receiver operating characteristics curves along with specificity, sensitivity, accuracy and efficiency values were determined for a variety of transient evoked otoacoustic emission/pure tone screening/tympanometry comparisons. The Transient Evoked Otoacoustic Emission failure rate for the group was 20.3%. The failure rate for pure tone screening was found to be 8.9%, whilst 18.6% of subjects failed a protocol consisting of combined pure tone screening and tympanometry results. In essence, findings from the comparison of overall Transient Evoked Otoacoustic Emission pass/fail with overall pure tone screening pass/fail suggested that use of a modified Rhode Island Hearing Assessment Project criterion would result in a very high probability that a child with a pass result has normal hearing (true negative). However, the hit rate was only moderate. Selection of a signal-to-noise ratio (SNR) criterion set at > or =1 dB appeared to provide the best test performance measures for the range of SNR values investigated. Test performance measures generally declined when tympanometry results were included, with the exception of lower false alarm rates and higher positive predictive values. The exclusion of low frequency data from the Transient Evoked Otoacoustic Emission SNR versus pure tone screening analysis resulted in improved performance measures. The present study poses several implications for the clinical implementation of Transient Evoked Otoacoustic Emission screening for entry level school children. Transient Evoked Otoacoustic Emission pass/fail criteria will require revision. The findings of the current investigation offer support to the possible replacement of pure tone screening with Transient Evoked Otoacoustic Emission testing for 6-year-old children. However, they do not suggest the replacement of the pure tone screening plus tympanometry battery.

  2. 40 CFR 80.62 - Vehicle test procedures to place vehicles in emitter group sub-fleets.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... following test procedures must be used to screen candidate vehicles for their exhaust THC emissions to place... vehicles may be tested for their exhaust THC emissions using the Federal test procedure as detailed in 40... emitter groups. (b) Alternatively, candidate vehicles may be screened for their exhaust THC emissions with...

  3. 40 CFR 80.62 - Vehicle test procedures to place vehicles in emitter group sub-fleets.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... following test procedures must be used to screen candidate vehicles for their exhaust THC emissions to place... vehicles may be tested for their exhaust THC emissions using the Federal test procedure as detailed in 40... emitter groups. (b) Alternatively, candidate vehicles may be screened for their exhaust THC emissions with...

  4. 40 CFR 80.62 - Vehicle test procedures to place vehicles in emitter group sub-fleets.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... following test procedures must be used to screen candidate vehicles for their exhaust THC emissions to place... vehicles may be tested for their exhaust THC emissions using the Federal test procedure as detailed in 40... emitter groups. (b) Alternatively, candidate vehicles may be screened for their exhaust THC emissions with...

  5. 40 CFR 80.62 - Vehicle test procedures to place vehicles in emitter group sub-fleets.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... following test procedures must be used to screen candidate vehicles for their exhaust THC emissions to place... vehicles may be tested for their exhaust THC emissions using the Federal test procedure as detailed in 40... emitter groups. (b) Alternatively, candidate vehicles may be screened for their exhaust THC emissions with...

  6. 40 CFR 80.62 - Vehicle test procedures to place vehicles in emitter group sub-fleets.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... following test procedures must be used to screen candidate vehicles for their exhaust THC emissions to place... vehicles may be tested for their exhaust THC emissions using the Federal test procedure as detailed in 40... emitter groups. (b) Alternatively, candidate vehicles may be screened for their exhaust THC emissions with...

  7. The use of transient evoked otoacoustic emissions as a hearing screen following grommet insertion.

    PubMed

    Dale, O T; McCann, L J; Thio, D; Wells, S C; Drysdale, A J

    2011-07-01

    This study aimed to evaluate the sensitivity of transient evoked otoacoustic emission testing as a screening tool for hearing loss in children, after grommet insertion. A prospective study was conducted of 48 children (91 ears) aged three to 16 years who had undergone grommet insertion for glue ear. At post-operative review, pure tone audiometry was performed followed by transient evoked otoacoustic emission testing. Outcomes for both tests, in each ear, were compared. The pure tone audiometry threshold was ≤ 20 dB in 85 ears (93.4 per cent), 25 dB in two ears (2.2 per cent) and ≥ 30 dB in four ears (4.4 per cent). Transient evoked otoacoustic emissions were detected in 69 ears (75.8 per cent). The sensitivity of transient evoked otoacoustic emission testing for detecting hearing loss was 100 per cent for ≥ 30 dB loss but only 66.7 per cent for ≥ 25 dB loss. Transient evoked otoacoustic emission testing offers a sensitive means of detecting hearing loss of ≥ 30 dB following grommet insertion in children. However, the use of such testing as a screening tool may miss some cases of mild hearing loss.

  8. [Systematic screening of deafness at a maternity ward using evoked otoacoustic emissions: practical aspects and parental attitudes].

    PubMed

    Moulin, A; Ferber-Viart, C; Berland, M; Dubreuil, C; Duclaux, R

    2001-09-01

    Evaluation of the feasibility and parental attitudes towards a hearing screening programme using evoked otoacoustic emissions, implemented in a maternity ward in France. A hearing screening test using transiently evoked otoacoustic emissions (TEOAE) was proposed to each baby, and an anonymous questionnaire was given to parents to assess their attitudes towards the screening procedure. Although the refusal of the test reached 16% (mainly during the first two weeks of the program), more than 92% of parents judged the test as being useful, and 65% wished it to be systematically done. However, nearly 35% of parents admitted to have a low level anxiety about being unnecessarily worried by the test results. One hundred and twenty-four babies were screened. Fifty three per cent of the tests have been performed in less than ten minutes, with an average of 12.2 minutes. This duration does not include delays due to programme and babies management. False positive rate (uni or bilateral fail) was 10.5% at the first stage. Repeating the test before discharge decreased the false positive rate to 6.5%. Although limited in time, this study shows that a systematic hearing screening programme using TEOAE is possible and should be done in France. False positive rate was below 7%, and the test was considered as useful by more than 90% of parents, although knowledge about deafness in childhood and its consequences were clearly insufficient.

  9. Contralateral ear occlusion for improving the reliability of otoacoustic emission screening tests.

    PubMed

    Papsin, Emily; Harrison, Adrienne L; Carraro, Mattia; Harrison, Robert V

    2014-01-01

    Newborn hearing screening is an established healthcare standard in many countries and testing is feasible using otoacoustic emission (OAE) recording. It is well documented that OAEs can be suppressed by acoustic stimulation of the ear contralateral to the test ear. In clinical otoacoustic emission testing carried out in a sound attenuating booth, ambient noise levels are low such that the efferent system is not activated. However in newborn hearing screening, OAEs are often recorded in hospital or clinic environments, where ambient noise levels can be 60-70 dB SPL. Thus, results in the test ear can be influenced by ambient noise stimulating the opposite ear. Surprisingly, in hearing screening protocols there are no recommendations for avoiding contralateral suppression, that is, protecting the opposite ear from noise by blocking the ear canal. In the present study we have compared transient evoked and distortion product OAEs measured with and without contralateral ear plugging, in environmental settings with ambient noise levels <25 dB SPL, 45 dB SPL, and 55 dB SPL. We found out that without contralateral ear occlusion, ambient noise levels above 55 dB SPL can significantly attenuate OAE signals. We strongly suggest contralateral ear occlusion in OAE based hearing screening in noisy environments.

  10. Efficacy of Distortion Product Oto-Acoustic Emission (OAE)/Auditory Brainstem Evoked Response (ABR) Protocols in Universal Neonatal Hearing Screening and Detecting Hearing Loss in Children <2 Years of Age.

    PubMed

    Mishra, Girish; Sharma, Yojana; Mehta, Kanishk; Patel, Gunjan

    2013-04-01

    Deafness is commonest curable childhood handicap. Most remedies and programmes don't address this issue at childhood level leading to detrimental impact on development of newborns. Aims and objectives are (A) screen all newborns for deafness and detect prevalence of deafness in children less than 2 years of age. and (B) assess efficacy of multi-staged OAE/ABR protocol for hearing screening. Non-randomized, prospective study from August 2008 to August 2011. All infants underwent a series of oto-acoustic emission (OAE) and final confirmatory auditory brainstem evoked response (ABR) audiometry. Finally, out of 1,101 children, 1,069 children passed the test while 12 children had impaired hearing after final testing, confirmed by ABR. Positive predictive value of OAE after multiple test increased to 100 %. OAE-ABR test series is effective in screening neonates and multiple tests reduce economic burden. High risk screening will miss nearly 50 % deaf children, thus universal screening is indispensable in picking early deafness.

  11. Testing of household products and materials for emission of toluene diisocyanate.

    PubMed

    Kelly, T J; Myers, J D; Holdren, M W

    1999-06-01

    Polyurethane products were subjected to chamber testing to determine their emission rates of 2,4- and 2,6-toluene diisocyanate (TDI). The polyurethane (PU) products included carpet padding, furniture cushions, sheet foam, varnishes, and sealants, as well as a commercially-applied water sealant product for concrete that contained up to 4 percent TDI by weight. The PU products were screened in a 9-L glass chamber, under elevated temperature and chamber loading conditions, using both a time-integrated sampling and analysis method specific for TDI and a continuous but non-specific real-time monitor for isocyanates. None of the products normally found in residences showed a positive response in the screening tests, indicating that TDI emissions and consequently toxic effects from such products are negligible. However, the commercially-applied water sealant gave a positive response in the screening test. Further testing of that product at realistic temperatures showed initial TDI emission rates of about 300,000 micrograms/m2/hr, with emissions lasting only one hour or less. At 21 and 27 degrees C, about 1 percent and 5 percent, respectively, of the TDI content of the product was released to the air. The emitted TDI was predominantly the 2,6-isomer, although the TDI originally present in the product was predominantly the 2,4-isomer.

  12. Arc Jet Screening Tests Of Phase 1 Orbiter Tile Repair Materials and Uncoated RSI High Temperature Emittance Measurements

    NASA Technical Reports Server (NTRS)

    DelPapa, Steven V.

    2005-01-01

    Arc jet tests of candidate tile repair materials and baseline Orbiter uncoated reusable surface insulation (RSI) were performed in the Johnson Space Center's (JSC) Atmospheric Reentry Materials and Structures Evaluation Facility (ARMSEF) from June 23, 2003, through August 19, 2003. These tests were performed to screen candidate tile repair materials by verifying the high temperature performance and determining the thermal stability. In addition, tests to determine the surface emissivity at high temperatures and the geometric shrinkage of bare RSI were performed. In addition, tests were performed to determine the surface emissivity at high temperatures and the geometric shrinkage of uncoated RSI.

  13. [Incidence of hypoacusia secondary to hyperbilirubinaemia in a universal neonatal auditory screening programme based on otoacoustic emissions and evoked auditory potentials].

    PubMed

    Núñez-Batalla, Faustino; Carro-Fernández, Pilar; Antuña-León, María Eva; González-Trelles, Teresa

    2008-03-01

    Hyperbilirubinaemia is a neonatal risk factor that has been proved to be associated with sensorineural hearing loss. A high concentration of unconjugated bilirubin place newborn children at risk of suffering toxic effects, including hypoacusia. Review of the newborn screening results with a diagnosis of pathological hyperbilirubinaemia as part of a hearing-loss early detection protocol in the general population based on otoemissions and evoked potentials. Retrospective study of 21 590 newborn children screened between 2002 and 2006. The selection criteria for defining pathological hyperbilirubinaemia were bilirubin concentrations in excess of 14 mg/dL in pre-term infants and 20 mg/dL in full-term babies. The Universal Neonatal Hearing Screening Programme is a two-phase protocol in which all children are initially subjected to a transient otoacoustic emissions test (TOAE). Children presenting risk factors associated with auditory neuropathy were always given brainstem auditory evoked potentials (BAEP). The patients identified as having severe hyperbilirubinaemia in the neonatal period numbered 109 (0.5 %) and 96 of these (88.07 %) passed the otoacoustic emissions test at the first attempt and 13 (11.93 %) did not; 11 of the 13 children in whom the otoacoustic emissions test was repeated passed it successfully. The 2 children who failed to pass the otoacoustic emissions test has normal BAEP results; 3 (2.75 %) of the newborn infants who passed the TOAE test did not pass the BAEP. Hyperbilirubinaemia values previously considered safe may harm the hearing system and give rise to isolated problems in auditory processing without being associated with other signs of classical kernicterus. Our results show that hyperbilirubinaemia-related auditory neuropathy reveals changes over time in the audiometric outcomes.

  14. Transient evoked oto-acoustic emission screening in newborns in Bogotá, Colombia: a retrospective study.

    PubMed

    Rojas, Jorge A; Bernal, Jaime E; García, Mary A; Zarante, Ignacio; Ramírez, Natalia; Bernal, Constanza; Gelvez, Nancy; Tamayo, Marta L

    2014-10-01

    The aim of this study was to investigate the characteristics and performance of transient evoked oto-acoustic emission (TEOAE) hearing screening in newborns in Colombia, and analyze all possible variables and factors affecting the results. An observational, descriptive and retrospective study with bivariate analysis was performed. The study population consisted of 56,822 newborns evaluated at the private institution, PREGEN. TEOAE testing was carried out as a pediatric hearing screening test from December 2003 to March 2012. The database from PREGEN was revised, and the protocol for evaluation included the same screening test performed twice. Demographic characteristics were recorded and the newborn's background was evaluated. Basic statistics of the qualitative and quantitative variables, and statistical analysis were obtained using the chi-square test. Of the 56,822 records examined, 0.28% were classed as abnormal, which corresponded to a prevalence of 1 in 350. In the screened newborns, 0.08% had a major abnormality or other clinical condition diagnosed, and 0.29% reported a family history of hearing loss. A prevalence of 6.7 in 10,000 was obtained for microtia, which is similar to the 6.4 in 10,000 previously reported in Colombia (database of the Latin-American Collaborative Study of Congenital Malformations - ECLAMC). Statistical analysis demonstrated an association between presenting with a major anomaly and a higher frequency of abnormal results on both TEOAE tests. Newborns in Colombia do not currently undergo screening for the early detection of hearing impairment. The results from this study suggest TEOAE screening tests, when performed twice, are able to detect hearing abnormalities in newborns. This highlights the need to improve the long-term evaluation and monitoring of patients in Colombia through diagnostic tests, and to provide tests that are both sensitive and specific. Furthermore, the use of TEOAE screening is justified by the favorable cost: benefit ratio demonstrated in many countries worldwide. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  15. [Perinatal factors affecting the detection of otoacoustic emissions in vaginally delivered, healthy newborns, during the first 48 hours of life].

    PubMed

    Sequi-Canet, José M; Sala-Langa, María J; Collar Del Castillo, José I

    2014-01-01

    Most hospitals perform neonatal hearing screening because it is a very useful procedure. Otoacoustic emissions are an ideal technique for this screening. We analyse the possible influence on screening results of some perinatal factors. We collected retrospective data from 8,239 healthy newborns delivered vaginally at the maternity ward of our hospital. We compared multiple perinatal factors vs the results of otoacoustic emissions performed within the first 48 h of life, before discharge. A total of 6.4% of newborns had an abnormal response and failed the screening. Univariate and multivariate analysis showed a significant (P<.0001) positive relationship between breastfeeding and normal otoacoustic emissions (OR: 0.65). Another, less significant factor was female gender. The remaining variables, including origin, education or employment status of the mother, maternal smoking, dystocic delivery, presentation, need for resuscitation, preterm labour (34-36 weeks), weight, length and frequent maternal pathology, such as streptococcus detection, hypothyroidism, hypertension or diabetes, were not significant. Breastfeeding was the most important factor related to a normal response in otoacoustic emissions. It may improve final results and reduce the number of neonates who need to be rescheduled for a repeated test, as well as the associated anxiety and the possibility of losing patients during follow-up. These are major problems in neonatal hearing screening. Copyright © 2013 Elsevier España, S.L. All rights reserved.

  16. Effects of background noise on recording of portable transient-evoked otoacoustic emission in newborn hearing screening.

    PubMed

    Salina, Husain; Abdullah, Asma; Mukari, Siti Zamratol Mai-sarah; Azmi, Mohd Tamil

    2010-04-01

    Transient-evoked otoacoustic emission (TEOAE) is a well-established screening tool for universal newborn hearing screening. The aims of this study are to measure the effects of background noise on recording of TEOAE and the duration required to complete the test at various noise levels. This study is a prospective study from June 2006 until May 2007. The study population were newborns from postnatal wards who were delivered at term pregnancy. Newborns who were more than 8-h old and passed a hearing screening testing using screening auditory brainstem response (SABRe) were further tested with TEOAE in four different test environments [isolation room in the ward during non-peak hour (E1), isolation room in the ward during peak hour (E2), maternal bedside in the ward during non-peak hour (E3) and maternal bedside in the ward during peak hour (E4)]. This study showed that test environment significantly influenced the time required to complete testing in both ears with F [534.23] = 0.945; P < 0.001 on the right ear and F [636.54] = 0.954; P < 0.001 on the left. Our study revealed that TEOAE testing was efficient in defining the presence of normal hearing in our postnatal wards at maternal bedside during non-peak hour with a specificity of 96.8%. Our study concludes that background noise levels for acceptable and accurate TEOAE recording in newborns should not exceed 65 dB A. In addition, when using TEOAE assessment in noisy environments, the time taken to obtain accurate results will greatly increase.

  17. Could the Use of Acoustic Reflexes Prior to Administering Distortion Product Otoacoustic Emissions (DPOAEs) Affect the Results of DPOAEs?

    PubMed

    Garrette, Rachel; Jones, Alisha L; Wilson, Martha W

    2018-05-15

    The purpose of this study is to investigate whether acoustic reflex threshold testing before administration of distortion product otoacoustic emissions can affect the results of the distortion product otoacoustic emissions testing using an automated protocol. Fifteen young adults with normal hearing ranging in age from 19 to 25 years participated in the study. All participants had clear external ear canals and normal Jerger Type A tympanograms and had passed a hearing screening. Testing was performed using the Interacoustics Titan acoustic reflex threshold and distortion product otoacoustic emissions protocol. Participants underwent baseline distortion product otoacoustic emissions. A paired-samples t test was conducted for both the right and left ears to assess within-group differences between baseline distortion product otoacoustic emissions and repeated distortion product otoacoustic emissions measures. No significant differences were found in distortion product otoacoustic emission measures following administration of acoustic reflexes. The use of a protocol when using an automated system that includes both acoustic reflexes and distortion product otoacoustic emissions is important. Overall, presentation of acoustic reflexes prior to measuring distortion product otoacoustic emission did not affect distortion product otoacoustic emission results; therefore, test sequence can be modified as needed.

  18. Power reflectance testing in newborns and infants.

    PubMed

    Lima, Ticianna Garambone de Cerqueira; Becker, Helena Maria Gonçalves; Becker, Celso Gonçalves; Ferreira, Daniele Barreto da Cunha; Resende, Camilo Brandão de; Guimarães, Roberto Eustáquio Santos

    2015-01-01

    Auditory screening in newborns allows for detection of hearing problems early in life. However, middle ear diseases can make the diagnosis more difficult. To evaluate the power reflectance test as an indicator of the middle ear disease and to compare it to tympanometry. Case study evaluating 105 newborns and infants who participated in the audiology screening in 2013. The following exams were performed: transient otoacoustic emissions, power reflectance, and tympanometry. In the optoacoustic emission evaluation, approximately 95% of the subjects passed the test. The specificity of power reflectance in all frequencies studied ranged from 75.3% to 95.9%, and that of tympanometry at 1000Hz ranged from 83% to 87.2%; there was agreement among these exams. The outcome of power reflectance tests at 2000Hz and 3000Hz showed a correlation with tympanometry and otoacoustic emissions, and these were the most appropriate frequencies to determine middle ear disease through power reflectance measurement. It was also observed that values of power reflectance above reference levels suggested the presence of fluid in the middle ear, and thus a conductive hearing loss. Copyright © 2015 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  19. Acoustic emission as a screening tool for ceramic matrix composites

    NASA Astrophysics Data System (ADS)

    Ojard, Greg; Goberman, Dan; Holowczak, John

    2017-02-01

    Ceramic matrix composites are composite materials with ceramic fibers in a high temperature matrix of ceramic or glass-ceramic. This emerging class of materials is viewed as enabling for efficiency improvements in many energy conversion systems. The key controlling property of ceramic matrix composites is a relatively weak interface between the matrix and the fiber that aids crack deflection and fiber pullout resulting in greatly increased toughness over monolithic ceramics. United Technologies Research Center has been investigating glass-ceramic composite systems as a tool to understand processing effects on material performance related to the performance of the weak interface. Changes in the interface have been shown to affect the mechanical performance observed in flexural testing and subsequent microstructural investigations have confirmed the performance (or lack thereof) of the interface coating. Recently, the addition of acoustic emission testing during flexural testing has aided the understanding of the characteristics of the interface and its performance. The acoustic emission onset stress changes with strength and toughness and this could be a quality tool in screening the material before further development and use. The results of testing and analysis will be shown and additional material from other ceramic matrix composite systems may be included to show trends.

  20. Proposal for a screening test to evaluate the fate of organic micropollutants in activated sludge.

    PubMed

    Salvetti, Roberta; Vismara, Renato; Dal Ben, Ilaria; Gorla, Elena; Romele, Laura

    2011-04-01

    The concentrations of organic micropollutants are usually low in wastewaters (order of magnitude of mg L(-1)). However, their emission standards, especially in the case of carcinogenic and bioaccumulating substances, are often much lower (order of magnitude of microg L(-1)). Since these substances, in some cases, can be adsorbable or volatile, their removal via volatilization, biodegradation or sludge adsorption in a wastewater treatment plant (WWTP) becomes a significant feature to include in the usual design process, in order to verify the emission standards in gas and sludge too. In this study a simple screening batch test for the evaluation of the fate of organic micropollutants in water, air and sludge is presented. The test is set up by means of simple laboratory instruments and simulates an activated sludge tank process. In this study the results obtained for four substances with different chemical properties (i.e. toluene, benz(a)anthracene, phenol and benzene) are presented. The screening test proposed can be a useful tool to assess in about one month the fate of organic micropollutants in an activated sludge tank of a WWTP. Moreover, the test can constitute a useful support in the use of mathematical models, since it allows the verification of model results and the calibration of the reactions involved in the removal process.

  1. Design and Development of an Electrostatic Screen Battery for Emission Control (ESBEC)

    PubMed Central

    Han, Taewon; Mainelis, Gediminas

    2017-01-01

    Current diesel particulate filters (DPFs) can effectively capture the exhaust particles, but they add to engine backpressure and accumulate particles during their operation, which results in the need to regenerate the DPFs by burning off the collected particles periodically. This regeneration results in aerosol emissions, especially in the 10–30 nanometer size range and contributes to ultrafine particle pollution. In this research, we designed and developed a prototype of a novel diesel exhaust control device: the Electrostatic Screen Battery for Emissions Control (ESBEC). The device features high particle collection efficiency without adding to the exhaust backpressure and without the need for thermal regeneration of the collected particles. The ESBEC consists of a series of metal mesh screens coated with a superhydrophobic substance and an integrated carbon fiber ionizer to charge the incoming particles. Multiple pairs of screens (e.g., 5 pairs) are arranged in a battery, in which one screen of each pair is supplied with high voltage, and the other is grounded, producing electrostatic field produced across the screens. The application of a superhydrophobic coating onto the screens allows easy removal of the collected particles using liquid without the need for thermal regeneration. The current prototypes of the device were tested with fluorescent polystyrene latex (PSL) particles of 0.2 and 1.2 μm in size and at 25 and 105 L/min sampling flow rates. The average collection efficiency was ~87% for 0.2 μm and ~95% for 1.2 μm PSL particles. In addition, the ESBEC was tested with actual diesel exhaust particles; here its performance was verified by visually inspecting deposition of particles on an after-filter with the device ON and OFF. In the next stages of this work, the ESBEC will be challenged with diesel exhaust at different mass concentrations and for different collection time periods. PMID:28983124

  2. Design and Development of an Electrostatic Screen Battery for Emission Control (ESBEC).

    PubMed

    Han, Taewon; Mainelis, Gediminas

    2017-05-01

    Current diesel particulate filters (DPFs) can effectively capture the exhaust particles, but they add to engine backpressure and accumulate particles during their operation, which results in the need to regenerate the DPFs by burning off the collected particles periodically. This regeneration results in aerosol emissions, especially in the 10-30 nanometer size range and contributes to ultrafine particle pollution. In this research, we designed and developed a prototype of a novel diesel exhaust control device: the Electrostatic Screen Battery for Emissions Control (ESBEC). The device features high particle collection efficiency without adding to the exhaust backpressure and without the need for thermal regeneration of the collected particles. The ESBEC consists of a series of metal mesh screens coated with a superhydrophobic substance and an integrated carbon fiber ionizer to charge the incoming particles. Multiple pairs of screens (e.g., 5 pairs) are arranged in a battery, in which one screen of each pair is supplied with high voltage, and the other is grounded, producing electrostatic field produced across the screens. The application of a superhydrophobic coating onto the screens allows easy removal of the collected particles using liquid without the need for thermal regeneration. The current prototypes of the device were tested with fluorescent polystyrene latex (PSL) particles of 0.2 and 1.2 μm in size and at 25 and 105 L/min sampling flow rates. The average collection efficiency was ~87% for 0.2 μm and ~95% for 1.2 μm PSL particles. In addition, the ESBEC was tested with actual diesel exhaust particles; here its performance was verified by visually inspecting deposition of particles on an after-filter with the device ON and OFF. In the next stages of this work, the ESBEC will be challenged with diesel exhaust at different mass concentrations and for different collection time periods.

  3. Ga-68-DOTATOC: Feasibility of high throughput screening by small animal PET using a clinical high-resolution PET/CT scanner

    NASA Astrophysics Data System (ADS)

    Hofmann, Michael; Weitzel, Thilo; Krause, Thomas

    2006-12-01

    As radio peptide tracers have been developed in recent years for the high sensitive detection of neuroendocrine tumors, still the broad application of other peptides to breast and prostate cancer is missing. A rapid screening of new peptides can, in theory, be based on in vivo screening in animals by PET/CT. To test this hypothesis and to asses the minimum screening time needed per animal, we used the application of Ga-68-DOTATOC PET/CT in rats as test system. The Ga-68-DOTATOC yields in a hot spot imaging with minimal background. To delineate liver and spleen, we performed PET/CT of 10 animals on a SIEMENS Biograph 16 LSO HIGHREZ after intravenous injection of 1.5 MBq Ga-68-DOTATOC per animal. Animals were mounted in an '18 slot' holding device and scanned for a single-bed position. The emission times for the PET scan was varied from 1 to 20 min. The images were assessed first for "PET only" and afterwards in PET/CT fusion mode. The detection of the two organs was good at emission times down to 1 min in PET/CT fusion mode. In the "PET only" scans, the liver was clearly to be identified down to 1 min emission in all animals. But the spleen could only be delineated only by 1 min of emission in the PET/CT-fusion mode. In conclusion the screening of "hot spot" enriching peptides is feasible. "PET only" is in terms of delineation of small organs by far inferior to PET/CT fusion. If animal tumors are above a diameter of 10 mm small, animal PET/CT using clinical high resolution scanners will enable rapid screening. Even the determination of bio-distributions becomes feasible by using list mode tools. The time for the whole survey of 18 animals including anesthesia, preparation and mounting was approximately 20 min. By use of several holding devices mounted simultaneously, a survey time of less than 1 h for 180 animals can be expected.

  4. Automatic classification of transiently evoked otoacoustic emissions using an artificial neural network.

    PubMed

    Buller, G; Lutman, M E

    1998-08-01

    The increasing use of transiently evoked otoacoustic emissions (TEOAE) in large neonatal hearing screening programmes makes a standardized method of response classification desirable. Until now methods have been either subjective or based on arbitrary response characteristics. This study takes an expert system approach to standardize the subjective judgements of an experienced scorer. The method that is developed comprises three stages. First, it transforms TEOAEs from waveforms in the time domain into a simplified parameter set. Second, the parameter set is classified by an artificial neural network that has been taught on a large database TEOAE waveforms and corresponding expert scores. Third, additional fuzzy logic rules automatically detect probable artefacts in the waveforms and synchronized spontaneous emission components. In this way, the knowledge of the experienced scorer is encapsulated in the expert system software and thereafter can be accessed by non-experts. Teaching and evaluation of the neural network was based on TEOAEs from a database totalling 2190 neonatal hearing screening tests. The database was divided into learning and test groups with 820 and 1370 waveforms respectively. From each recorded waveform a set of 12 parameters was calculated, representing signal static and dynamic properties. The artifical network was taught with parameter sets of only the learning groups. Reproduction of the human scorer classification by the neural net in the learning group showed a sensitivity for detecting screen fails of 99.3% (299 from 301 failed results on subjective scoring) and a specificity for detecting screen passes of 81.1% (421 of 519 pass results). To quantify the post hoc performance of the net (generalization), the test group was then presented to the network input. Sensitivity was 99.4% (474 from 477) and specificity was 87.3% (780 from 893). To check the efficiency of the classification method, a second learning group was selected out of the previous test group, and the previous learning group was used as the test group. Repeating learning and test procedures yielded 99.3% sensitivity and 80.7% specificity for reproduction, and 99.4% sensitivity and 86.7% specificity for generalization. In all respects, performance was better than for a previously optimized method based simply on cross-correlation between replicate non-linear waveforms. It is concluded that classification methods based on neural networks show promise for application to large neonatal screening programmes utilizing TEOAEs.

  5. Hearing screening in children with skeletal dysplasia.

    PubMed

    Tunkel, David E; Kerbavaz, Richard; Smith, Beth; Rose-Hardison, Danielle; Alade, Yewande; Hoover-Fong, Julie

    2011-12-01

    To determine the prevalence of hearing loss and abnormal tympanometry in children with skeletal dysplasia. Clinical screening program. National convention of the Little People of America. Convenience sample of volunteers aged 18 years or younger with skeletal dysplasias. Hearing screening with behavioral testing and/or otoacoustic emissions, otoscopy, and tympanometry. A failed hearing screen was defined as hearing 35 dB HL (hearing level) or greater at 1 or more tested frequencies or by a "fail" otoacoustic emissions response. Types B and C tympanograms were considered abnormal. A total of 58 children (aged ≤18 years) with skeletal dysplasia enrolled, and 56 completed hearing screening. Forty-one children had normal hearing (71%); 9 failed in 1 ear (16%); and 6 failed in both ears (10%). Forty-four children had achondroplasia, and 31 had normal hearing in both ears (71%); 8 failed hearing screening in 1 ear (18%), and 3 in both ears (7%). Tympanometry was performed in 45 children, with normal tympanograms found in 21 (47%), bilateral abnormal tympanograms in 15 (33%), and unilateral abnormal tympanograms in 9 (20%). Fourteen children with achondroplasia had normal tympanograms (42%); 11 had bilateral abnormal tympanograms (33%); and 8 had unilateral abnormal tympanograms (24%). For those children without functioning tympanostomy tubes, there was a 9.5 times greater odds of hearing loss if there was abnormal tympanometry (P = .03). Hearing loss and middle-ear disease are both highly prevalent in children with skeletal dysplasias. Abnormal tympanometry is highly associated with the presence of hearing loss, as expected in children with eustachian tube dysfunction. Hearing screening with medical intervention is recommended for these children.

  6. Transient Evoked and Distortion Product Otoacoustic Emissions in a Group of Neonates

    PubMed Central

    Silva, Giovanna Cesar; Delecrode, Camila Ribas; Kemp, Adriana Tahara; Martins, Fabiana; Cardoso, Ana Claudia Vieira

    2015-01-01

    Introduction The most commonly used method in neonatal hearing screening programs is transient evoked otoacoustic emissions in the first stage of the process. There are few studies comparing transient evoked otoacoustic emissions with distortion product, but some authors have investigated the issue. Objective To correlate the results of transient evoked and distortion product otoacoustic emissions in a Brazilian maternity hospital. Methods This is a cross-sectional, comparative, and prospective study. The study included 579 newborns, ranging from 6 to 54 days of age, born in a low-risk maternity hospital and assessed for hearing loss. All neonates underwent hearing screening by transient evoked and distortion product otoacoustic emissions. The results were analyzed using the Spearman correlation test to relate the two procedures. Results The pass index on transient evoked otoacoustic emissions was 95% and on distortion product otoacoustic emissions was 91%. The comparison of the two procedures showed that 91% of neonates passed on both procedures, 4.5% passed only on transient evoked otoacoustic emissions, 0.5% passed only on distortion product otoacoustic emissions, and 4% failed on both procedures. The inferential analysis showed a significant strong positive relationship between the two procedures. Conclusion The failure rate was higher in distortion product otoacoustic emissions when compared with transient evoked; however, there was correlation between the results of the procedures. PMID:26157501

  7. Risk factors for hearing loss in infants under universal hearing screening program in Northern Thailand

    PubMed Central

    Poonual, Watcharapol; Navacharoen, Niramon; Kangsanarak, Jaran; Namwongprom, Sirianong

    2016-01-01

    Objective To define the risk factors for hearing loss in infants (aged 3 months) under universal hearing screening program. Materials and methods A total of 3,120 infants (aged 3 months) who underwent hearing screening using a universal hearing screening program using automated otoacoustic emission test between November 1, 2010 and May 31, 2012 in Uttaradit Hospital, Buddhachinaraj Hospital, and Sawanpracharuk Hospital (tertiary hospitals) located in Northern Thailand were included in this prospective cohort study. Results Of the 3,120 infants, 135 (4.3%) were confirmed to have hearing loss with the conventional otoacoustic emission test. Five of these 135 infants (3.7%) with hearing loss showed test results consistent with auditory brainstem responses. From the univariable analysis, there were eleven potential risk factors associated with hearing deterioration. On multivariable analysis, the risk factors independently associated with hearing loss at 3 months were birth weight 1,500–2,500 g (risk ratio [RR] 1.6, 95% confidence interval [CI] 1.1–2.6), APGAR score <6 at 5 minutes (RR 2.2, 95% CI 1.1–4.4), craniofacial anomalies (RR 2.5, 95% CI 1.6–4.2), sepsis (RR 1.8, 95% CI 1.0–3.2), and ototoxic exposure (RR 4.1, 95% CI 1.9–8.6). Conclusion This study concluded that low birth weight, APGAR score <6 at 5 minutes, craniofacial anomalies, sepsis, and ototoxic exposure are the risk factors for bilateral hearing loss in infants (aged 3 months) and proper tests should be performed to identify these risk factors. As an outcome, under the present circumstances, it is suggested that infirmary/physicians/general practitioners/health action centers/polyclinics should carry out universal hearing screening in all infants before 36 weeks. The public health policy of Thailand regarding a universal hearing screening program is important for the prevention of disability and to enhance people’s quality of life. PMID:26766912

  8. Experimental clean combustor program, phase 1. [aircraft exhaust/gas analysis - gas turbine engines

    NASA Technical Reports Server (NTRS)

    Roberts, R.; Peduzzi, A.; Vitti, G. E.

    1975-01-01

    A program of screening three low emission combustors for conventional takeoff and landing, by testing and analyzing thirty-two configurations is presented. Configurations were tested that met the emission goals at idle operating conditions for carbon monoxide and for unburned hydrocarbons (emission index values of 20 and 4, respectively). Configurations were also tested that met a smoke number goal of 15 at sea-level take-off conditions. None of the configurations met the goal for oxides of nitrogen emissions at sea-level take-off conditions. The best configurations demonstrated oxide of nitrogen emission levels that were approximately 61 percent lower than those produced by the JT9D-7 engine, but these levels were still approximately 24 percent above the goal of an emission index level of 10. Additional combustor performance characteristics, including lean blowout, exit temperature pattern factor and radial profile, pressure loss, altitude stability, and altitude relight characteristics were documented. The results indicate the need for significant improvement in the altitude stability and relight characteristics. In addition to the basic program for current aircraft engine combustors, seventeen combustor configurations were evaluated for advanced supersonic technology applications. The configurations were tested at cruise conditions, and a conceptual design was evolved.

  9. Evaluation of volatile organic emissions from hazardous waste incinerators.

    PubMed Central

    Sedman, R M; Esparza, J R

    1991-01-01

    Conventional methods of risk assessment typically employed to evaluate the impact of hazardous waste incinerators on public health must rely on somewhat speculative emissions estimates or on complicated and expensive sampling and analytical methods. The limited amount of toxicological information concerning many of the compounds detected in stack emissions also complicates the evaluation of the public health impacts of these facilities. An alternative approach aimed at evaluating the public health impacts associated with volatile organic stack emissions is presented that relies on a screening criterion to evaluate total stack hydrocarbon emissions. If the concentration of hydrocarbons in ambient air is below the screening criterion, volatile emissions from the incinerator are judged not to pose a significant threat to public health. Both the screening criterion and a conventional method of risk assessment were employed to evaluate the emissions from 20 incinerators. Use of the screening criterion always yielded a substantially greater estimate of risk than that derived by the conventional method. Since the use of the screening criterion always yielded estimates of risk that were greater than that determined by conventional methods and measuring total hydrocarbon emissions is a relatively simple analytical procedure, the use of the screening criterion would appear to facilitate the evaluation of operating hazardous waste incinerators. PMID:1954928

  10. Screening for hearing loss in the elderly using distortion product otoacoustic emissions, pure tones, and a self-assessment tool.

    PubMed

    Jupiter, Tina

    2009-12-01

    To determine whether distortion product otoacoustic emissions (DPOAEs) could be used as a hearing screening tool with elderly individuals living independently, and to compare the utility of different screening protocols: (a) 3 pure-tone screening protocols consisting of 30 dB HL at 1, 2, and 3 kHz; 40 dB HL at 1, 2, and 3 kHz; or 40 dB HL at 1 and 2 kHz; (b) the Hearing Handicap Inventory for the Elderly-Screening version (HHIE-S); (c) pure tones at 40 dB HL at 1 and 2 kHz plus the HHIE-S; and (d) DPOAEs. A total of 106 elderly individuals age 65-91 years were screened using the above protocols. Pass/fail results showed that most individuals failed at 30 dB HL, followed by DPOAEs, the 40-dB HL protocols, the HHIE-S alone, and the combined pure-tone/HHIE-S protocol. All screening results were associated except the HHIE-S and 30 dB HL and the HHIE-S and DPOAEs. A McNemar analysis revealed that the differences between the correlated pass/fail results were significant except for the HHIE-S and 40 dB at 1 and 2 kHz. DPOAEs can be used to screen the elderly, with the advantage that individuals do not have to voluntarily respond to the test.

  11. Evidence for a Right-Ear Advantage in Newborn Hearing Screening Results.

    PubMed

    Ari-Even Roth, Daphne; Hildesheimer, Minka; Roziner, Ilan; Henkin, Yael

    2016-12-06

    The aim of the present study was to investigate the effect of ear asymmetry, order of testing, and gender on transient-evoked otoacoustic emission (TEOAE) pass rates and response levels in newborn hearing screening. The screening results of 879 newborns, of whom 387 (study group) passed screening successfully in only one ear in the first TEOAE screening, but passed screening successfully in both ears thereafter, and 492 (control group) who passed screening successfully in both ears in the first TEOAE, were retrospectively examined for pass rates and TEOAE characteristics. Results indicated a right-ear advantage, as manifested by significantly higher pass rates in the right ear (61% and 39% for right and left ears, respectively) in the study group, and in 1.75 dB greater TEOAE response amplitudes in the control group. The right-ear advantage was enhanced when the first tested ear was the right ear (76%). When the left ear was tested first, pass rates were comparable in both ears. The right-ear advantage in pass rates was similar in females versus males, but manifested in 1.5 dB higher response amplitudes in females compared with males, regardless of the tested ear and order of testing in both study and control groups. The study provides further evidence for the functional lateralization of the auditory system at the cochlear level already apparent soon after birth in both males and females. While order of testing plays a significant role in the asymmetry in pass rates, the innate right-ear advantage seems to be a more dominant contributor. © The Author(s) 2016.

  12. Evidence for a Right-Ear Advantage in Newborn Hearing Screening Results

    PubMed Central

    Hildesheimer, Minka; Roziner, Ilan; Henkin, Yael

    2016-01-01

    The aim of the present study was to investigate the effect of ear asymmetry, order of testing, and gender on transient-evoked otoacoustic emission (TEOAE) pass rates and response levels in newborn hearing screening. The screening results of 879 newborns, of whom 387 (study group) passed screening successfully in only one ear in the first TEOAE screening, but passed screening successfully in both ears thereafter, and 492 (control group) who passed screening successfully in both ears in the first TEOAE, were retrospectively examined for pass rates and TEOAE characteristics. Results indicated a right-ear advantage, as manifested by significantly higher pass rates in the right ear (61% and 39% for right and left ears, respectively) in the study group, and in 1.75 dB greater TEOAE response amplitudes in the control group. The right-ear advantage was enhanced when the first tested ear was the right ear (76%). When the left ear was tested first, pass rates were comparable in both ears. The right-ear advantage in pass rates was similar in females versus males, but manifested in 1.5 dB higher response amplitudes in females compared with males, regardless of the tested ear and order of testing in both study and control groups. The study provides further evidence for the functional lateralization of the auditory system at the cochlear level already apparent soon after birth in both males and females. While order of testing plays a significant role in the asymmetry in pass rates, the innate right-ear advantage seems to be a more dominant contributor. PMID:27927982

  13. The importance of retesting the hearing screening as an indicator of the real early hearing disorder.

    PubMed

    Silva, Daniela Polo Camargo da; Lopez, Priscila Suman; Ribeiro, Georgea Espíndola; Luna, Marcos Otávio de Mesquita; Lyra, João César; Montovani, Jair Cortez

    2015-01-01

    Early diagnosis of hearing loss minimizes its impact on child development. We studied factors that influence the effectiveness of screening programs. To investigate the relationship between gender, weight at birth, gestational age, risk factors for hearing loss, venue for newborn hearing screening and "pass" and "fail" results in the retest. Prospective cohort study was carried out in a tertiary referral hospital. The screening was performed in 565 newborns through transient evoked otoacoustic emissions in three admission units before hospital discharge and retest in the outpatient clinic. Gender, weight at birth, gestational age, presence of risk indicators for hearing loss and venue for newborn hearing screening were considered. Full-term infants comprised 86% of the cases, preterm 14%, and risk factors for hearing loss were identified in 11%. Considering the 165 newborns retested, only the venue for screening, Intermediate Care Unit, was related to "fail" result in the retest. Gender, weight at birth, gestational age and presence of risk factors for hearing loss were not related to "pass" and/or "fail" results in the retest. The screening performed in intermediate care units increases the chance of continued "fail" result in the Transient Otoacoustic Evoked Emissions test. Copyright © 2015 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  14. 40 CFR Appendix III to Part 266 - Tier II Emission Rate Screening Limits for Free Chlorine and Hydrogen Chloride

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 28 2013-07-01 2013-07-01 false Tier II Emission Rate Screening Limits for Free Chlorine and Hydrogen Chloride III Appendix III to Part 266 Protection of Environment... to Part 266—Tier II Emission Rate Screening Limits for Free Chlorine and Hydrogen Chloride Terrain...

  15. 40 CFR Appendix III to Part 266 - Tier II Emission Rate Screening Limits for Free Chlorine and Hydrogen Chloride

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 27 2014-07-01 2014-07-01 false Tier II Emission Rate Screening Limits for Free Chlorine and Hydrogen Chloride III Appendix III to Part 266 Protection of Environment... to Part 266—Tier II Emission Rate Screening Limits for Free Chlorine and Hydrogen Chloride Terrain...

  16. 40 CFR Appendix III to Part 266 - Tier II Emission Rate Screening Limits for Free Chlorine and Hydrogen Chloride

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 27 2011-07-01 2011-07-01 false Tier II Emission Rate Screening Limits for Free Chlorine and Hydrogen Chloride III Appendix III to Part 266 Protection of Environment... to Part 266—Tier II Emission Rate Screening Limits for Free Chlorine and Hydrogen Chloride Terrain...

  17. 40 CFR Appendix III to Part 266 - Tier II Emission Rate Screening Limits for Free Chlorine and Hydrogen Chloride

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 26 2010-07-01 2010-07-01 false Tier II Emission Rate Screening Limits for Free Chlorine and Hydrogen Chloride III Appendix III to Part 266 Protection of Environment... to Part 266—Tier II Emission Rate Screening Limits for Free Chlorine and Hydrogen Chloride Terrain...

  18. 40 CFR Appendix III to Part 266 - Tier II Emission Rate Screening Limits for Free Chlorine and Hydrogen Chloride

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 28 2012-07-01 2012-07-01 false Tier II Emission Rate Screening Limits for Free Chlorine and Hydrogen Chloride III Appendix III to Part 266 Protection of Environment... to Part 266—Tier II Emission Rate Screening Limits for Free Chlorine and Hydrogen Chloride Terrain...

  19. Economic evaluation of long-term impacts of universal newborn hearing screening.

    PubMed

    Chiou, Shu-Ti; Lung, Hou-Ling; Chen, Li-Sheng; Yen, Amy Ming-Fang; Fann, Jean Ching-Yuan; Chiu, Sherry Yueh-Hsia; Chen, Hsiu-Hsi

    2017-01-01

    Little is known about the long-term efficacious and economic impacts of universal newborn hearing screening (UNHS). An analytical Markov decision model was framed with two screening strategies: UNHS with transient evoked otoacoustic emission (TEOAE) test and automatic acoustic brainstem response (aABR) test against no screening. By estimating intervention and long-term costs on treatment and productivity losses and the utility of life years determined by the status of hearing loss, we computed base-case estimates of the incremental cost-utility ratios (ICURs). The scattered plot of ICUR and acceptability curve was used to assess the economic results of aABR versus TEOAE or both versus no screening. A hypothetical cohort of 200,000 Taiwanese newborns. TEOAE and aABR dominated over no screening strategy (ICUR = $-4800.89 and $-4111.23, indicating less cost and more utility). Given $20,000 of willingness to pay (WTP), the probability of being cost-effective of aABR against TEOAE was up to 90%. UNHS for hearing loss with aABR is the most economic option and supported by economically evidence-based evaluation from societal perspective.

  20. The experimental clean combustor program: Description and status to November 1975

    NASA Technical Reports Server (NTRS)

    Niedzwiecki, R. W.

    1975-01-01

    The generation of technology was studied for the development of advanced commercial CTOL aircraft engines with lower exhaust emissions than current aircraft. The program is in three phases. Phase 1, already completed, consisted of screening tests of low pollution combustor concepts. Phase 2, currently in progress, consists of test rig refinement of the most promising combustor concepts. Phase 2 test results are reported. Phase 3, also currently in progress, consists of incorporating and evaluating the best combustors as part of a complete engine. Engine test plans and pollution sampling techniques are described in this report. Program pollution goals, specified at engine idle and take-off conditions, are idle emission index value of 20 and 4 for carbon monoxide (CO) and total unburned hydrocarbons (THC), respectively, and at take-off are an oxides of nitrogen (NOx) emission index level of 10 and a smoke number of 15. Pollution data were obtained at all engine operating conditions. Results are presented in terms of emission index and also in terms of the Environmental Protection Agency's 1979 Standards Parameter.

  1. Pollution reduction technology program for small jet aircraft engines: Class T1

    NASA Technical Reports Server (NTRS)

    Bruce, T. W.; Davis, F. G.; Mongia, H. C.

    1977-01-01

    Small jet aircraft engines (EPA class T1, turbojet and turbofan engines of less than 35.6 kN thrust) were evaluated with the objective of attaining emissions reduction consistent with performance constraints. Configurations employing the technological advances were screened and developed through full scale rig testing. The most promising approaches in full-scale engine testing were evaluated.

  2. A novel emissive projection display (EPD) on transparent phosphor screen

    NASA Astrophysics Data System (ADS)

    Cheng, Botao; Sun, Leonard; Yu, Ge; Sun, Ted X.

    2017-03-01

    A new paradigm of digital projection is on the horizon, based on innovative emissive screen that are made fully transparent. It can be readily applied and convert any surface to a high image quality emissive digital display, without affecting the surface appearance. For example, it can convert any glass window or windshield to completely see-through display, with unlimited field of view and viewing angles. It also enables a scalable and economic projection display on a pitch-black emissive screen with black level and image contrast that rivals other emissive displays such as plasma display or OLED.

  3. Amplitude changes in otoacoustic emissions after exposure to industrial noise.

    PubMed

    Baradarnfar, Mohammad Hossein; Karamifar, Kayvan; Mehrparvar, Amir Houshang; Mollasadeghi, Abolfazl; Gharavi, Marjan; Karimi, Ghasem; Vahidy, Mohammad Reza; Baradarnfar, Amin; Mostaghaci, Mehrdad

    2012-01-01

    Noise-induced hearing loss (NIHL) is a frequent problem in industrial settings, especially where a high noise level is present. It is permanent, and irreversible, but preventable. Routine audiometry (an objective and time consuming) test is used for NIHL screening. Otoacoustic emissions (OAEs) are recently proposed as a more sensitive test for early diagnosis of NIHL. In this study, we aimed to compare the results of pure tone audiometry (PTA) with OAE in the diagnosis of NIHL. In a cross-sectional study on 120 workers (in three groups: Not exposed to noise, exposed to noise without NIHL and exposed to noise with NIHL), we compared the results of PTA and OAE. OAE can detect some changes in the function of hearing system in subjects exposed to noise, and these changes are apparently prior to hearing loss, which is diagnosed by PTA. OAE is a more sensitive method for the early diagnosis of cochlear damage than PTA, and can be performed in industrial settings for NIHL screening.

  4. Targeting regional pediatric congenital hearing loss using a spatial scan statistic.

    PubMed

    Bush, Matthew L; Christian, Warren Jay; Bianchi, Kristin; Lester, Cathy; Schoenberg, Nancy

    2015-01-01

    Congenital hearing loss is a common problem, and timely identification and intervention are paramount for language development. Patients from rural regions may have many barriers to timely diagnosis and intervention. The purpose of this study was to examine the spatial and hospital-based distribution of failed infant hearing screening testing and pediatric congenital hearing loss throughout Kentucky. Data on live births and audiological reporting of infant hearing loss results in Kentucky from 2009 to 2011 were analyzed. The authors used spatial scan statistics to identify high-rate clusters of failed newborn screening tests and permanent congenital hearing loss (PCHL), based on the total number of live births per county. The authors conducted further analyses on PCHL and failed newborn hearing screening tests, based on birth hospital data and method of screening. The authors observed four statistically significant (p < 0.05) high-rate clusters with failed newborn hearing screenings in Kentucky, including two in the Appalachian region. Hospitals using two-stage otoacoustic emission testing demonstrated higher rates of failed screening (p = 0.009) than those using two-stage automated auditory brainstem response testing. A significant cluster of high rate of PCHL was observed in Western Kentucky. Five of the 54 birthing hospitals were found to have higher relative risk of PCHL, and two of those hospitals are located in a very rural region of Western Kentucky within the cluster. This spatial analysis in children in Kentucky has identified specific regions throughout the state with high rates of congenital hearing loss and failed newborn hearing screening tests. Further investigation regarding causative factors is warranted. This method of analysis can be useful in the setting of hearing health disparities to focus efforts on regions facing high incidence of congenital hearing loss.

  5. Colorado SIP: 5 CCR 1001-13, Reg 11, Motor Vehicle Emissions Inspection Program—Part A, General Provisions, Area of Applicability, Schedules for Obtaining Certification of Emissions Control, Definitions, Exemptions, and Clean Screening/Remote Sensing

    EPA Pesticide Factsheets

    Colorado SIP: 5 CCR 1001-13, Reg 11, Motor Vehicle Emissions Inspection Program—Part A, General Provisions, Area of Applicability, Schedules for Obtaining Certification of Emissions Control, Definitions, Exemptions, and Clean Screening/Remote Sensing

  6. Lessons learned in preparing method 29 filters for compliance testing audits.

    PubMed

    Martz, R F; McCartney, J E; Bursey, J T; Riley, C E

    2000-01-01

    Companies conducting compliance testing are required to analyze audit samples at the time they collect and analyze the stack samples if audit samples are available. Eastern Research Group (ERG) provides technical support to the EPA's Emission Measurements Center's Stationary Source Audit Program (SSAP) for developing, preparing, and distributing performance evaluation samples and audit materials. These audit samples are requested via the regulatory Agency and include spiked audit materials for EPA Method 29-Metals Emissions from Stationary Sources, as well as other methods. To provide appropriate audit materials to federal, state, tribal, and local governments, as well as agencies performing environmental activities and conducting emission compliance tests, ERG has recently performed testing of blank filter materials and preparation of spiked filters for EPA Method 29. For sampling stationary sources using an EPA Method 29 sampling train, the use of filters without organic binders containing less than 1.3 microg/in.2 of each of the metals to be measured is required. Risk Assessment testing imposes even stricter requirements for clean filter background levels. Three vendor sources of quartz fiber filters were evaluated for background contamination to ensure that audit samples would be prepared using filters with the lowest metal background levels. A procedure was developed to test new filters, and a cleaning procedure was evaluated to see if a greater level of cleanliness could be achieved using an acid rinse with new filters. Background levels for filters supplied by different vendors and within lots of filters from the same vendor showed a wide variation, confirmed through contact with several analytical laboratories that frequently perform EPA Method 29 analyses. It has been necessary to repeat more than one compliance test because of suspect metals background contamination levels. An acid cleaning step produced improvement in contamination level, but the difference was not significant for most of the Method 29 target metals. As a result of our studies, we conclude: Filters for Method 29 testing should be purchased in lots as large as possible. Testing firms should pre-screen new boxes and/or new lots of filters used for Method 29 testing. Random analysis of three filters (top, middle, bottom of the box) from a new box of vendor filters before allowing them to be used in field tests is a prudent approach. A box of filters from a given vendor should be screened, and filters from this screened box should be used both for testing and as field blanks in each test scenario to provide the level of quality assurance required for stationary source testing.

  7. DC partial discharge/environmental test screening of space TWTS

    NASA Astrophysics Data System (ADS)

    Hai, F.; Paschen, K. W.

    Direct-current partial discharge/environmental tests are being conducted on traveling wave tubes (TWTs) designated for long-term space operation to screen out tubes with high voltage defects. Two types of TWTs with different external high-voltage insulation are being examined: (1) TWTs with polymeric potting, and (2) TWTs with ceramic feedthroughs. Detection of high voltage defects in the form of cracks and seprations in potted systems is enhanced by combining dc partial discharge testing with environmental (temperature and pressure) testing. These defects are usually caused by high stresses in the potting produced during temperature excursions by the difference in thermal expansion between the potting material and the confining ceramic-metal structure. Tests of all-ceramic-insulated TWTs indicate that the high voltage problem is internal to the vacuum envelope and requires both leakage and discharge measurements for diagnosis. This problem appears to be field emission from contaminated surfaces.

  8. Does the New European Driving Cycle (NEDC) really fail to capture the NOX emissions of diesel cars in Europe?

    PubMed

    Degraeuwe, Bart; Weiss, Martin

    2017-03-01

    Tests with Portable Emissions Measurement Systems (PEMS) have demonstrated that diesel cars emit several times more NO X on the road than during certification on the New European Driving Cycle (NEDC). Policy makers and scientists have attributed the discrepancy to the unrealistically low dynamics and the narrow temperature range of NEDC testing. Although widely accepted, this assumption was never been put under scientific scrutiny. Here, we demonstrate that the narrow NEDC test conditions explain only a small part of the elevated on-road NO X emissions of diesel cars. For seven Euro 4-6 diesel cars, we filter from on-road driving those events that match the NEDC conditions in instantaneous speed, acceleration, CO 2 emissions, and ambient temperature. The resulting on-road NO X emissions exceed by 206% (median) those measured on the NEDC, whereas the NO X emissions of all unfiltered on-road measurements exceed the NEDC emissions by 266% (median). Moreover, when applying the same filtering of on-road data to two other driving cycles (WLTP and CADC), the resulting on-road NO X emissions exceed by only 13% (median) those measured over the respective cycles. This result demonstrates that our filtering method is accurate and robust. If neither the low dynamics nor the limited temperature range of NEDC testing can explain the elevated NO X emissions of diesel cars, emissions control strategies used during NEDC testing must be inactive or modulated on the road, even if vehicles are driven under certification-like conditions. This points to defeat strategies that warrant further investigations by type-approval authorities and, in turn, limitations in the enforcement of the European vehicle emissions legislation by EU Member States. We suggest applying our method as a simple yet effective tool to screen and select vehicles for in-depth analysis by the competent certification authorities. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  9. ADAPTATION OF THE ADVANCED STATISTICAL TRAJECTORY REGIONAL AIR POLLUTION (ASTRAP) MODEL TO THE EPA VAX COMPUTER - MODIFICATIONS AND TESTING

    EPA Science Inventory

    The Advanced Statistical Trajectory Regional Air Pollution (ASTRAP) model simulates long-term transport and deposition of oxides of and nitrogen. t is a potential screening tool for assessing long-term effects on regional visibility from sulfur emission sources. owever, a rigorou...

  10. Identification of neonatal hearing impairment: evaluation of transient evoked otoacoustic emission, distortion product otoacoustic emission, and auditory brain stem response test performance.

    PubMed

    Norton, S J; Gorga, M P; Widen, J E; Folsom, R C; Sininger, Y; Cone-Wesson, B; Vohr, B R; Mascher, K; Fletcher, K

    2000-10-01

    The purpose of this study was to compare the performance of transient evoked otoacoustic emissions (TEOAEs), distortion product otoacoustic emissions (DPOAEs), and auditory brain stem responses (ABRs) as tools for identification of neonatal hearing impairment. A total of 4911 infants including 4478 graduates of neonatal intensive care units, 353 well babies with one or more risk factors for hearing loss (Joint Committee on Infant Hearing, 1994) and 80 well babies without risk factor who did not pass one or more neonatal test were targeted as the potential subject pool on which test performance would be assessed. During the neonatal period, they were evaluated using TEOAEs in response to an 80 dB pSPL click, DPOAE responses to two stimulus conditions (L1 = L2 = 75 dB SPL and L1 = 65 dB SPL L2 = 50 dB SPL), and ABR elicited by a 30 dB nHL click. In an effort to describe test performance, these "at-risk" infants were asked to return for behavioral audiologic assessments, using visual reinforcement audiometry (VRA) at 8 to 12 mo corrected age, regardless of neonatal test results. Sixty-four percent of these subjects returned and reliable VRA data were obtained on 95.6% of these returnees. This approach is in contrast to previous studies in which, by necessity, efforts were made to follow only those infants who "failed" the neonatal screening tests. The accuracy of the neonatal measures in predicting hearing status at 8 to 12 mo corrected age was determined. Only those infants who provided reliable, monaural VRA test results were included in the analysis. Separate analyses were performed without regard to intercurrent events (i.e., events between the neonatal and VRA tests that could cause their results to disagree), and then after accounting for the possible influence of intercurrent events such as otitis media and late-onset or progressive hearing loss. Low refer rates were achieved for the stopping criteria used in the present study, especially when a protocol similar to the one recommended in the National Institutes of Health (1993) Consensus Conference Report was followed. These analyses, however, do not completely describe test performance because they did not compare neonatal screening test results with a gold standard test of hearing. Test performance, as measured by the area under a relative operating characteristic curve, were similar for all three neonatal tests when neonatal test results were compared with VRA data obtained at 8 to 12 mo corrected age. However, ABRs were more successful at determining auditory status at 1 kHz, compared with the otoacoustic emission (OAE) tests. Performance was more similar across all three tests when they were used to identify hearing loss at 2 and 4 kHz. No test performed perfectly. Using either the two- or three-frequency pure-tone average (PTA), with a fixed false alarm rate of 20%, hit rates for the neonatal tests, in general, exceeded 80% when hearing impairment was defined as behavioral thresholds > or =30 dB HL. All three tests performed similarly when a two-frequency (2 and 4 kHz) PTA was used as the gold standard; OAE test performance decreased when a three-frequency PTA (adding 1 kHz) was used as the gold standard definition. For both PTA and all three neonatal screening measures, however, hit rate increased as the magnitude of hearing loss increased. Singly, all three neonatal hearing screening tests resulted in low refer rates, especially if referrals for follow-up were made only for the cases in which stopping criteria were not met in both ears. Following a protocol similar to that recommended in the National Institutes of Health (1993) Consensus Conference report resulted in refer rates that were less than 4%. TEOAEs at 80 dB pSPL, DPOAE at L1 = 65, L2 = 50 dB SPL and ABR at 30 dB nHL measured during the neonatal period, and as implemented in the current study, performed similarly at predicting behavioral hearing status at 8 to 12

  11. Preliminary Results of Field Emission Cathode Tests

    NASA Technical Reports Server (NTRS)

    Sovey, James S.; Kovaleski, Scott D.

    2001-01-01

    Preliminary screening tests of field emission cathodes such as chemical vapor deposited (CVD) diamond, textured pyrolytic graphite, and textured copper were conducted at background pressures typical of electric thruster test facilities to assess cathode performance and stability. Very low power electric thrusters which provide tens to hundreds micronewtons of thrust may need field emission neutralizers that have a capability of tens to hundreds of microamperes. From current voltage characteristics, it was found that the CVD diamond and textured metals cathodes clearly satisfied the Fowler-Nordheim emission relation. The CVD diamond and a textured copper cathode had average current densities of 270 and 380 mA/sq cm, respectively, at the beginning-of-life. After a few hours of operation the cathode emission currents degraded by 40 to 75% at background pressures in the 10(exp -5) Pa to 10(exp -4) Pa range. The textured pyrolytic graphite had a modest current density at beginning-of-life of 84 mA/sq cm, but this cathode was the most stable of all. Extended testing of the most promising cathodes is warranted to determine if current degradation is a burn-in effect or whether it is a long-term degradation process. Preliminary experiments with ferroelectric emission cathodes, which are ceramics with spontaneous electric polarization, were conducted. Peak current densities of 30 to 120 mA/sq cm were obtained for pulse durations of about 500 ns in the 10(exp -4) Pa pressure range.

  12. Screening effect in matrix graphene / SiC planar field emmiters

    NASA Astrophysics Data System (ADS)

    Jityaev, I. L.; Svetlichnyi, A. M.; Kolomiytsev, A. S.; Ageev, O. A.

    2017-11-01

    The paper describes simulation of matrix field emission nanostructures on the basis of graphene on a semi-insulating silicon carbide. The planar spike-type field emission cathodes were measured. The electric field distribution in an interelectrode gap of the emission structure was obtained. The models take into account the distance between cathode tops. Screening effect condition was detected in planar field emission structure and a way of eliminating was proposed.

  13. Experimental clean combustor program, phase 1

    NASA Technical Reports Server (NTRS)

    Bahr, D. W.; Gleason, C. C.

    1975-01-01

    Full annular versions of advanced combustor designs, sized to fit within the CF6-50 engine, were defined, manufactured, and tested at high pressure conditions. Configurations were screened, and significant reductions in CO, HC, and NOx emissions levels were achieved with two of these advanced combustor design concepts. Emissions and performance data at a typical AST cruise condition were also obtained along with combustor noise data as a part of an addendum to the basic program. The two promising combustor design approaches evolved in these efforts were the Double Annular Combustor and the Radial/Axial Combustor. With versions of these two basic combustor designs, CO and HC emissions levels at or near the target levels were obtained. Although the low target NOx emissions level was not obtained with these two advanced combustor designs, significant reductions were relative to the NOx levels of current technology combustors. Smoke emission levels below the target value were obtained.

  14. A SCREENING LEVEL RISK ASSESSMENT OF THE INDIRECT IMPACTS FROM THE COLUMBUS WASTE TO ENERGY FACILITY IN COLUMBUS, OHIO

    EPA Science Inventory

    Testing for emissions of dioxins from the stack of the Columbus, Ohio Waste to Energy (WTE) municipal solid waste combustion facility in 1992 implied that dioxin concentrations in stack gas averaged 328 ng TEQ/m3. The incinerator had been in operation since the early 1980s. In ...

  15. Screening organic chemicals in commerce for emissions in the context of environmental and human exposure.

    PubMed

    Breivik, Knut; Arnot, Jon A; Brown, Trevor N; McLachlan, Michael S; Wania, Frank

    2012-08-01

    Quantitative knowledge of organic chemical release into the environment is essential to understand and predict human exposure as well as to develop rational control strategies for any substances of concern. While significant efforts have been invested to characterize and screen organic chemicals for hazardous properties, relatively less effort has been directed toward estimating emissions and hence also risks. Here, a rapid throughput method to estimate emissions of discrete organic chemicals in commerce has been developed, applied and evaluated to support screening studies aimed at ranking and identifying chemicals of potential concern. The method builds upon information in the European Union Technical Guidance Document and utilizes information on quantities in commerce (production and/or import rates), chemical function (use patterns) and physical-chemical properties to estimate emissions to air, soil and water within the OECD for five stages of the chemical life-cycle. The method is applied to 16,029 discrete substances (identified by CAS numbers) from five national and international high production volume lists. As access to consistent input data remains fragmented or even impossible, particular attention is given to estimating, evaluating and discussing uncertainties in the resulting emission scenarios. The uncertainty for individual substances typically spans 3 to 4 orders of magnitude for this initial tier screening method. Information on uncertainties in emissions is useful as any screening or categorization methods which solely rely on threshold values are at risk of leading to a significant number of either false positives or false negatives. A limited evaluation of the screening method's estimates for a sub-set of about 100 substances, compared against independent and more detailed emission scenarios presented in various European Risk Assessment Reports, highlights that up-to-date and accurate information on quantities in commerce as well as a detailed breakdown on chemical function are critically needed for developing more realistic emission scenarios.

  16. Novel diesel exhaust filters for underground mining vehicles

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bickel, K.L.; Taubert, T.R.

    1995-12-31

    The U.S. Bureau of Mines (USBM) pioneered the development of disposable filters for reducing diesel particulate emissions from permissible mining machines. The USBM is now evaluating filter media that can withstand the high exhaust temperatures on nonpermissible machines. The goal of the evaluation is to find an inexpensive medium that can be cleaned or disposed of after use, and will reduce particulate emissions by 50 % or more. This report summarizes the results from screening tests of a lava rock and woven fiberglass filter media. The lava rock media exhibited low collection efficiencies, but with very low increases in exhaustmore » back pressure. Preliminary results indicate a collection efficiency exceeding 80 % for the woven fiber media. Testing of both media is continuing.« less

  17. In use performance of catalytic converters on properly maintained high mileage vehicles

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sabourin, M.A.; Larson, R.E.; Donahue, K.S.

    1986-01-01

    A test program to evaluate the performance of catalytic converters from fifty-six 1981 and 1982 model year high mileage properly maintained in-use vehicles (from 21 engine families) was performed by the Certification Division of the Office of Mobile Sources (EPA). The program is called the Catalyst Change Program. All program vehicles were screened for proper maintenance and for mileages that ranged from 35,000 to 60,000 miles. Among vehicles belonging to 21 high sales volume and high technology engine and emission control system designs tested, poor catalyst performance was determined to be a significant contributor to emissions failure of properly-maintained vehiclesmore » at or near their warranted useful life mileage.« less

  18. Field Emission Enhancement and the Field-Screening Effect Reduction using Carbon Nanopipettes as Cold Cathodes

    NASA Astrophysics Data System (ADS)

    Safir, Abdelilah; Mudd, David; Yazdanpanah, Mehdi; Dobrokhotov, Vladimir; Sumanasekera, Gamini; Cohn, Robert

    2008-03-01

    In this work, we report a recent experimental study of high emission current densities exceeding 10mA/cm^2 and breakdown electric field lower than 5Volts/μm from novel cold cathodes such as conical shaped carbon nanopipettes (CNP). CNP were grown by CVD on Pt wire and have apex as sharp as 10nm with length between 3-6μm. The emission experiments were conducted under vacuum in a scanning electron microscope for individual CNP and in a dedicated chamber for bulk samples. CNP's conical bases and low density contribute significantly to the reduction of the screening effect and to the field emission enhancement. The experimental value for the field enhancement factor, γ, was about 867. Comparing emission results taken from CNP and aligned multiwall carbon nanotubes (MWNT) show that the ratio between γCNP and γMWNT is ˜1.6 which contributes to the reduction of screening effect. The emission from multilayers of graphene was also studied. High emission current (20μA) demonstrates promising emission properties of graphene.

  19. Polish universal neonatal hearing screening program-4-year experience (2003-2006).

    PubMed

    Szyfter, Witold; Wróbel, Maciej; Radziszewska-Konopka, Marzanna; Szyfter-Harris, Joanna; Karlik, Michał

    2008-12-01

    The aim of this paper is to share our experience and observations in running the Universal Neonatal Hearing Screening Program on a national level, present results and indicate some problems that have arisen during these 4 years. Polish Universal Neonatal Hearing Screening Program started back in 2002 in all neonatal units in Poland. Implemented testing methods consisted of test of transient evoked otoacoustic emission (TEOAE) performed in all new born children in their first 2-3 days of life and auditory brainstem response testing (ABR) conducted on children, who did not meet the TEOAE pass criteria. Additional questionnaire registered information on ototoxic drugs and family history of hearing impairment in every newborn. Diagnosed children were further referred for treatment and rehabilitation. After 4 years of running the program (between 2003 and 2006) a total number of 1,392,427 children were screened for hearing impairment, what stands for 96.3% of all delivered babies, registered in Poland. The screening program enabled to identify and refer for further treatment 2485 children with various types of hearing loss, 312 with profound (0.02% of population) and 145 with severe sensorineural hearing loss (0.11% of population). Our results indicate the accuracy of newborn hearing screening which remain an issue. Although improvement is needed in both intervention systems and diagnostic follow-up of hospitals, the Polish Universal Neonatal Hearing Program fully has achieved the main goal, the identification and treatment of hearing impaired children.

  20. Cancer screening with whole-body PET/CT for healthy asymptomatic people in Japan: re-evaluation of its test validity and radiation exposure.

    PubMed

    Ghotbi, Nader; Iwanaga, Masako; Ohtsuru, Akira; Ogawa, Yoji; Yamashita, Shunichi

    2007-01-01

    The use of Positron Emission Tomography (PET) or PET/CT for voluntary cancer screening of asymptomatic individuals is becoming common in Japan, though the utility of such screening is still controversial. This study estimated the general test validity and effective radiation dose for PET/CT cancer screening of healthy Japanese people by evaluating four standard indices (sensitivity, specificity, positive/negative predictive values), and predictive values with including prevalence for published literature and simulation-based Japanese data. CT and FDG-related dosage data were gathered from the literature and then extrapolated to the scan parameters at a model PET center. We estimated that the positive predictive value was only 3.3% in the use of PET/CT for voluntary cancer screening of asymptomatic Japanese individuals aged 50-59 years old, whose average cancer prevalence was 0.5%. The total effective radiation dose of a single whole-body PET/CT scan was estimated to be 6.34 to 9.48 mSv for the average Japanese individual, at 60 kg body weight. With PET/CT cancer screening in Japan, many healthy volunteers screened as false positive are exposed to at least 6.34 mSv without getting any real benefit. More evaluation concerning the justification of applying PET/CT for healthy people is necessary.

  1. Gravitational radiation from compact binary systems in screened modified gravity

    NASA Astrophysics Data System (ADS)

    Zhang, Xing; Liu, Tan; Zhao, Wen

    2017-05-01

    Screened modified gravity (SMG) is a kind of scalar-tensor theory with screening mechanisms, which can suppress the fifth force in dense regions and allow theories to evade the solar system and laboratory tests. In this paper, we investigate how the screening mechanisms in SMG affect the gravitational radiation damping effects, calculate in detail the rate of the energy loss due to the emission of tensor and scalar gravitational radiations, and derive their contributions to the change in the orbital period of the binary system. We find that the scalar radiation depends on the screened parameters and the propagation speed of scalar waves, and the scalar dipole radiation dominates the orbital decay of the binary system. For strongly self-gravitating bodies, all effects of scalar sector are strongly suppressed by the screening mechanisms in SMG. By comparing our results to observations of binary system PSR J 1738 +0333 , we place the stringent constraints on the screening mechanisms in SMG. As an application of these results, we focus on three specific models of SMG (chameleon, symmetron, and dilaton), and derive the constraints on the model parameters, respectively.

  2. Prevalence and referral rates in neonatal hearing screening program using two step hearing screening protocol in Chennai - A prospective study.

    PubMed

    Vignesh, S S; Jaya, V; Sasireka, B I; Sarathy, Kamala; Vanthana, M

    2015-10-01

    To estimate the prevalence and referral rates in well born and high risk babies using two step hearing screening protocol with Distortion Product Otoacoustic Emissions (DPOAE) and Automated Auditory Brainstem Response (AABR). A prospective study was carried out on 1405 neonates (983 well born babies and 422 high risk babies) who were screened during May 2013 to January 2015 at Institute of Obstetrics and Gynecology, Madras Medical College, Chennai. All neonates were screened using two step screening protocol. They were initially tested with DPOAE. Referred babies in DPOAE were screened with AABR subsequently. Among 1405 (100%) neonates 983 (69.96%) were well born babies and 422 (30.03%) were high risk babies. Total referral rate in DPOAE was found to be 311 (22.13%) among which 195 (13.87%) were well born babies and 116 (8.25%) were high risk babies. Out of 311 babies 31 (2.20%) babies were referred in AABR screening. In 31 babies referred in AABR 11(0.78%) were from well born group and 20 (1.42%) were from the high risk group. Further diagnostic evaluation of these babies, 2 (0.14%) were confirmed to have hearing loss. This study reveals, the prevalence of congenital hearing loss in our population is 1.42 per 1000 babies. Using two step protocol especially AABR along with DPOAE at the initial level of testing significantly reduces referral rates in new born screening programs. Also AABR decreases the false positive responses hence increasing the efficiency of screening program. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  3. Analytical screening of low emissions, high performance duct burners for supersonic cruise aircraft engines

    NASA Technical Reports Server (NTRS)

    Lohmann, R. A.; Riecke, G. T.

    1977-01-01

    An analytical screening study was conducted to identify duct burner concepts capable of providing low emissions and high performance in advanced supersonic engines. Duct burner configurations ranging from current augmenter technology to advanced concepts such as premix-prevaporized burners were defined. Aerothermal and mechanical design studies provided the basis for screening these configurations using the criteria of emissions, performance, engine compatibility, cost, weight and relative risk. Technology levels derived from recently defined experimental low emissions main burners are required to achieve both low emissions and high performance goals. A configuration based on the Vorbix (Vortex burning and mixing) combustor concept was analytically determined to meet the performance goals and is consistent with the fan duct envelope of a variable cycle engine. The duct burner configuration has a moderate risk level compatible with the schedule of anticipated experimental programs.

  4. High performance field emission of silicon carbide nanowires and their applications in flexible field emission displays

    NASA Astrophysics Data System (ADS)

    Cui, Yunkang; Chen, Jing; Di, Yunsong; Zhang, Xiaobing; Lei, Wei

    2017-12-01

    In this paper, a facile method to fabricate the flexible field emission devices (FEDs) based on SiC nanostructure emitters by a thermal evaporation method has been demonstrated. The composition characteristics of SiC nanowires was characterized by X-ray diffraction (XRD), selected area electron diffraction (SAED) and energy dispersive X-ray spectrometer (EDX), while the morphology was revealed by field emission scanning electron microscopy (SEM) and high resolution transmission electron microscopy (HRTEM). The results showed that the SiC nanowires grew along the [111] direction with the diameter of ˜110 nm and length of˜30 μm. The flexible FEDs have been fabricated by transferring and screen-printing the SiC nanowires onto the flexible substrates exhibited excellent field emission properties, such as the low turn-on field (˜0.95 V/μm) and threshold field (˜3.26 V/μm), and the high field enhancement factor (β=4670). It is worth noting the current density degradation can be controlled lower than 2% per hour during the stability tests. In addition, the flexible FEDs based on SiC nanowire emitters exhibit uniform bright emission modes under bending test conditions. As a result, this strategy is very useful for its potential application in the commercial flexible FEDs.

  5. Emission factor development for the malt beverage, wine, and distilled spirits industries

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lapp, T.; Shrager, B.; Safriet, D.

    Midwest Research Institute is currently developing emission factors for inclusion in AP-42 Chapter 9, Food and Agricultural Industries. Three of the sections cover the production of malt beverages, wine, and distilled spirits. The malt beverage segment focuses on the development of ethanol emission factors for filling operations, which were recently identified as the large source of brewery ethanol emissions. The discussion includes a description of the production process and emissions factors for breweries, a history of emission factories for breweries, a description of emission testing conducted at two large breweries, and a presentation of some of the emission factors formore » malt beverage production. The wine industry segment focuses on emissions from the fermentation stage for red and white wines, the pomace screen and pomace press for red wines, and bottling of white wine. Emission factors are presented for ethanol emissions from each of these sources as well as other VOC emissions from the fermentation process. A discussion of the wine production process is presented. A discussion of the emission sources and available emission factors is presented for the distilled spirits industry segment. Factors are presented for the fermentation and aging stages. A process description is presented for the production of Bourbon whisky.« less

  6. Validity of "sputtering and re-condensation" model in active screen cage plasma nitriding process

    NASA Astrophysics Data System (ADS)

    Saeed, A.; Khan, A. W.; Jan, F.; Abrar, M.; Khalid, M.; Zakaullah, M.

    2013-05-01

    The validity of "sputtering and re-condensation" model in active screen plasma nitriding for nitrogen mass transfer mechanism is investigated. The dominant species including NH, Fe-I, N2+, N-I and N2 along with Hα and Hβ lines are observed in the optical emission spectroscopy (OES) analysis. Active screen cage and dc plasma nitriding of AISI 316 stainless steel as function of treatment time is also investigated. The structure and phases composition of the nitrided layer is studied by X-ray diffraction (XRD). Surface morphology is studied by scanning electron microscopy (SEM) and hardness profile is obtained by Vicker's microhardness tester. Increasing trend in microhardness is observed in both cases but the increase in active screen plasma nitriding is about 3 times greater than that achieved by dc plasma nitriding. On the basis of metallurgical and OES observations the use of "sputtering and re-condensation" model in active screen plasma nitriding is tested.

  7. Hazard assessment of exhaust emissions - The next generation of fast and reliable tools for in vitro screening

    NASA Astrophysics Data System (ADS)

    Rothen-Rutishauser, B.

    2017-12-01

    Hazard assessment of exhaust emissions - The next generation of fast and reliable tools for in vitro screening Barbara Rothen-Rutishauser Adolphe Merkle Institute, University of Fribourg, Switzerland; barbara.rothen@unifr.ch Pollution by vehicles is a major problem for the environment due to the various components in the exhaust gasses that are emitted into the atmosphere. A large number of epidemiological studies demonstrate the profound impact of vehicle emissions upon human health [1-3]. Such studies however, are unable to attribute a given subset of emissions to a certain adverse effect, which renders decision making difficult. Standardized protocols for exhaust toxicity assessment are lacking and it relies in many aspects on epidemiological and in vivo studies (animals), which are very time and cost-intensive and suffer from considerable ethical issues. An overview about the current state of research and clinical aspects in the field, as well as about the development of sophisticated in vitro approaches mimicking the inhalation of airborne particles / exhaust for the toxicological testing of engine emissions will be provided. Data will be presented that show that the combination of an air-liquid exposure system and 3D lung-cell culture model offers an adequate tool for fast and reliable investigations of complete exhaust toxicity as well as the effects of particulate fraction [4,5]. This approach yields important results for novel and improved emission technologies in the early stages of product development. [1] Donaldson et al. Part Fibre Toxicol 2005, 2: 10. [2] Ghio et al. J Toxicol Environ Health B Crit Rev 2012, 15: 1-21. [3] Peters et al. Res Rep Health Eff Inst 2009, 5-77. [4] Bisig et al. Emiss Control Sci Technol 2015, 1: 237-246. [5] Steiner et al. Atmos Environ 2013, 81: 380-388.

  8. Computer-aided screening system for cervical precancerous cells based on field emission scanning electron microscopy and energy dispersive x-ray images and spectra

    NASA Astrophysics Data System (ADS)

    Jusman, Yessi; Ng, Siew-Cheok; Hasikin, Khairunnisa; Kurnia, Rahmadi; Osman, Noor Azuan Bin Abu; Teoh, Kean Hooi

    2016-10-01

    The capability of field emission scanning electron microscopy and energy dispersive x-ray spectroscopy (FE-SEM/EDX) to scan material structures at the microlevel and characterize the material with its elemental properties has inspired this research, which has developed an FE-SEM/EDX-based cervical cancer screening system. The developed computer-aided screening system consisted of two parts, which were the automatic features of extraction and classification. For the automatic features extraction algorithm, the image and spectra of cervical cells features extraction algorithm for extracting the discriminant features of FE-SEM/EDX data was introduced. The system automatically extracted two types of features based on FE-SEM/EDX images and FE-SEM/EDX spectra. Textural features were extracted from the FE-SEM/EDX image using a gray level co-occurrence matrix technique, while the FE-SEM/EDX spectra features were calculated based on peak heights and corrected area under the peaks using an algorithm. A discriminant analysis technique was employed to predict the cervical precancerous stage into three classes: normal, low-grade intraepithelial squamous lesion (LSIL), and high-grade intraepithelial squamous lesion (HSIL). The capability of the developed screening system was tested using 700 FE-SEM/EDX spectra (300 normal, 200 LSIL, and 200 HSIL cases). The accuracy, sensitivity, and specificity performances were 98.2%, 99.0%, and 98.0%, respectively.

  9. A test protocol for assessing the hearing status of students with special needs.

    PubMed

    Chen, Hsiao-Chuan; Wang, Nan-Mai; Chiu, Wen-Chen; Liu, Shu-Yu; Chang, Yi-Ping; Lin, Pei-Yu; Chung, King

    2014-10-01

    Individuals with disabilities are often reported to have a high prevalence of undetected hearing disorders/loss, but there is no standardized hearing test protocol for this population. The purposes of this study were (1) to examine the hearing status of students with special needs in Taiwan, and (2) to investigate the use of an on-site hearing test protocol that would adequately detect hearing problems in this population and reduce unnecessary referrals for off-site follow-up services. A total of 238 students enrolled in two schools for special education and one habilitation center participated in the study. Most students had intellectual disabilities and some also had additional syndromes or disorders. A hearing screening protocol including otoscopy, tympanometry, and distortion product otoacoustic emissions was administered to examine students' outer, middle, and inner ear functions, respectively. Pure tone tests were then administered as an on-site follow-up for those who failed or could not be tested using the screening protocol. Only 32.4% of students passed. When administered alone, the referral rate of otoscopy, tympanometry, and otoacoustic emissions were 38.7%, 46.0%, and 48.5%, respectively. The integration of these subtests revealed 52.1% of students needed follow-up services, 11.8% could not be tested, 2.5% had documented hearing loss, and 1.3% needed to be monitored because of negative middle ear pressure. The inclusion of pure tone audiometry increased the passing rate by 9.9% and provided information on hearing sensitivity for an additional 8.6% of students. Hearing assessments and regular hearing screening should be provided as an integral part of health care services for individuals with special needs because of high occurrences of excessive cerumen, middle ear dysfunction, and sensorineural hearing loss. The training of care-givers and teachers of students with special needs is encouraged so that they can help identify hearing problems and reduce the negative impact of hearing disorders and hearing loss. The screening protocol needs to include subtests that examine the status of different parts of their auditory system. The addition of pure tone audiometry as an on-site follow-up tool reduced the rate of off-site referrals and provided more information on hearing sensitivity. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  10. PERSONAL COMPUTER MONITORS: A SCREENING EVALUATION OF VOLATILE ORGANIC EMISSIONS FROM EXISTING PRINTED CIRCUIT BOARD LAMINATES AND POTENTIAL POLLUTION PREVENTION ALTERNATIVES

    EPA Science Inventory

    The report gives results of a screening evaluation of volatile organic emissions from printed circuit board laminates and potential pollution prevention alternatives. In the evaluation, printed circuit board laminates, without circuitry, commonly found in personal computer (PC) m...

  11. Pollution reduction technology program for small jet aircraft engines, phase 1

    NASA Technical Reports Server (NTRS)

    Bruce, T. W.; Davis, F. G.; Kuhn, T. E.; Mongia, H. C.

    1977-01-01

    A series of combustor pressure rig screening tests was conducted on three combustor concepts applied to the TFE731-2 turbofan engine combustion system for the purpose of evaluating their relative emissions reduction potential consistent with prescribed performance, durability, and envelope contraints. The three concepts and their modifications represented increasing potential for reducing emission levels with the penalty of increased hardware complexity and operational risk. Concept 1 entailed advanced modifications to the present production TFE731-2 combustion system. Concept 2 was based on the incorporation of an axial air-assisted airblast fuel injection system. Concept 3 was a staged premix/prevaporizing combustion system. Significant emissions reductions were achieved in all three concepts, consistent with acceptable combustion system performance. Concepts 2 and 3 were identified as having the greatest achievable emissions reduction potential, and were selected to undergo refinement to prepare for ultimate incorporation within an engine.

  12. Development of aircraft lavatory compartments with improved fire resistance characteristics. Phase 4: Sandwich panel decorative ink development

    NASA Technical Reports Server (NTRS)

    Jayarajan, A.; Johnson, G. A.; Korver, G. L.; Anderson, R. A.

    1983-01-01

    Five chemically different resin systems with improved fire resistance properties were studied for a possible screenprinting ink application. Fire resistance is hereby defined as the cured ink possessing improvements in flammability, smoke emission, and thermal stability. The developed ink is for application to polyvinyl fluoride film. Only clear inks without pigments were considered. Five formulations were evaluated compared with KC4900 clear acrylic ink, which was used as a baseline. The tests used in the screening evaluation included viscosity, smoke and toxic gas emission, limiting oxygen index (LOI), and polyvinyl fluoride film (PVF) printability. A chlorofluorocarbon resin (FPC461) was selected for optimization studies. The parameters for optimization included screenprinting process performance, quality of coating, and flammability of screenprinted 0.051-mm (0.002-in.) white Tedlar. The quality of the screenprinted coating on Tedlar is dependent on viscosity, curing time, adhesion to polyvinyl fluoride film, drying time (both inscreen and as an applied film), and silk screen mesh material and porosity.

  13. Breast Cancer Treatment in the Era of Molecular Imaging

    PubMed Central

    Edelhauser, Gundula; Funovics, Martin

    2008-01-01

    Summary Molecular imaging employs molecularly targeted probes to visualize and often quantify distinct disease-specific markers and pathways. Modalities like intravital confocal or multiphoton microscopy, near-infrared fluorescence combined with endoscopy, surface reflectance imaging, or fluorescence-mediated tomography, and radionuclide imaging with positron emission tomography (PET) and single-photon emission computed tomography (SPECT) are increasingly used for small animal high-throughput screening, drug development and testing, and monitoring gene therapy experiments. In the clinical treatment of breast cancer, PET and SPECT as well as magnetic resonance-based molecular imaging are already established for the staging of distant disease and intrathoracic nodal status, for patient selection regarding receptor-directed treatments, and to gain early information about treatment efficacy. In the near future, reporter gene imaging during gene therapy and further spatial and qualitative characterization of the disease can become clinically possible with radionuclide and optical methods. Ultimately, it may be expected that every level of breast cancer treatment will be affected by molecular imaging, including screening. PMID:21048912

  14. The NASA broad-specification fuels combustion technology program: An assessment of phase 1 test results

    NASA Technical Reports Server (NTRS)

    Fear, J. S.

    1983-01-01

    An assessment is made of the results of Phase 1 screening testing of current and advanced combustion system concepts using several broadened-properties fuels. The severity of each of several fuels-properties effects on combustor performance or liner life is discussed, as well as design techniques with the potential to offset these adverse effects. The selection of concepts to be pursued in Phase 2 refinement testing is described. This selection takes into account the relative costs and complexities of the concepts, the current outlook on pollutant emissions control, and practical operational problems.

  15. Correlated terahertz acoustic and electromagnetic emission in dynamically screened InGaN/GaN quantum wells

    NASA Astrophysics Data System (ADS)

    van Capel, P. J. S.; Turchinovich, D.; Porte, H. P.; Lahmann, S.; Rossow, U.; Hangleiter, A.; Dijkhuis, J. I.

    2011-08-01

    We investigate acoustic and electromagnetic emission from optically excited strained piezoelectric In0.2Ga0.8N/GaN multiple quantum wells (MQWs), using optical pump-probe spectroscopy, time-resolved Brillouin scattering, and THz emission spectroscopy. A direct comparison of detected acoustic signals and THz electromagnetic radiation signals demonstrates that transient strain generation in InGaN/GaN MQWs is correlated with electromagnetic THz generation, and both types of emission find their origin in ultrafast dynamical screening of the built-in piezoelectric field in the MQWs. The measured spectral intensity of the detected Brillouin signal corresponds to a maximum strain amplitude of generated acoustic pulses of 2%. This value coincides with the static lattice-mismatch-induced strain in In0.2Ga0.8N/GaN, demonstrating the total release of static strain in MQWs via impulsive THz acoustic emission. This confirms the ultrafast dynamical screening mechanism in MQWs as a highly efficient method for impulsive strain generation.

  16. Fire resistant films for aircraft applications

    NASA Technical Reports Server (NTRS)

    Kourtides, D. A.

    1983-01-01

    Alternative sandwich panel decorative films were investigated as replacements for the polyvinyl fluoride currently used in aircraft interiors. Candidate films were studied for flammability, smoke emission, toxic gas emission, flame spread, and suitability as a printing surface for the decorative acrylic ink system. Several of the candidate films tested were flame modified polyvinyl fluoride, polyvinylidene fluoride, polyimide, polyamide, polysulfone, polyphenylsulfone, polyethersulfone, polybenzimidazole, polycarbonate, polyparabanic acid, polyphosphazene, polyetheretherketon, and polyester. The films were evaluated as pure films only, films silk-screened with an acrylic ink, and films adhered to a phenolic fiberglass substrate. Films which exhibited the highest fire resistant properties included PEEK polyetheretherketon, Aramid polyamide, and ISO-BPE polyester.

  17. A screening level risk assessment of the indirect impacts from the Columbus Waste to Energy facility in Columbus, Ohio

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lorber, M.; Cleverly, D.; Schaum, J.

    1996-12-31

    Testing for emissions of dioxins from the stack of the Columbus, Ohio Waste to Energy (WTE) municipal solid waste combustion facility in 1992 implied that dioxin emissions could approach 1,000 grams of dioxin toxic equivalents (TEQs) per year. The incinerator has been in operation since the early 1980s. Several varying activities to further evaluate or curtail emissions were conducted by local, state and federal agencies in 1994. Also in that year, US EPA`s Region 5 issued an emergency order under Section 7003 of RCRA requiring the facility to install maximum Achievable Control Technology (MACT). As part of their justification formore » this emergency order, Region 5 used a screening level risk assessment of potential indirect impacts. This paper describes this assessment. The exposure setting is a hypothetical dairy farm where individuals on the farm obtain their beef, milk, and vegetables from home sources. A 70-year exposure scenario is considered, which includes 45 years of facility operation at the pre- and post-MACT emission rates, followed by 25 years of impact due to residual soil concentrations. Soil dermal contact, inhalation, and breast milk exposures were also considered for this assessment. The source term, or dioxin loadings to this setting, were derived from air dispersion modeling of emissions from the Columbus WTE. A key finding of the assessment was that exposures to dioxin in beef and milk dominated the estimated risks, with excess cancer risk form these two pathways estimated at 2.8 {times} 10{sup {minus}4}. A second key finding was that over 90% of a lifetime of impact from these two pathways, and the inhalation and vegetable ingestion pathways, has already occurred due to pre-MACT emissions.« less

  18. Cognition and screening for hearing loss in nursing home residents.

    PubMed

    Jupiter, Tina

    2012-10-01

    To compare hearing screening results using pure tones and distortion product otoacoustic emissions (DPOAEs) with nursing home residents who have dementia and explore the relationship of hearing impairment and cognitive function using the Mini- Mental Status Evaluation (MMSE). A correlational design was implemented to evaluate residents in a large inner city nursing home. One hundred one nursing home residents 65-108 years. DPOAEs and pure tone screenings were conducted at 30 dB HL and 40 dB HL at 1, 2, and 3 kHz. Pure tone thresholds at 1, 2, and 3 kHz were obtained. The MMSE was administered to all participants. Results showed that all residents failed the DPOAE screen, 97.1% failed at 30 dB HL, and 90.0% failed at 40 dB HL. Kendall's tau, phi correlation, linear by linear association, and χ(2) results indicated no significant relationship for any of the screening protocols and cognitive status other than a significant finding with left ear screening at 40 dB HL. Logistic regression analysis indicated that individuals who passed the screen had better MMSE scores. Results of the t test and Mann-Whitney U test revealed a significant difference in cognitive function for residents with a mild hearing loss compared with those with a more significant hearing loss. For screening nursing home residents, 40 dB HL screening level or DPOAEs can be used. The significant finding that residents with greater than a mild hearing loss have poorer cognitive function reinforces the importance of identifying residents with a hearing loss and providing rehabilitation and follow-up. Copyright © 2012 American Medical Directors Association, Inc. Published by Elsevier Inc. All rights reserved.

  19. Development of Multiwell-Plate Methods Using Pure Cultures of Methanogens To Identify New Inhibitors for Suppressing Ruminant Methane Emissions.

    PubMed

    Weimar, M R; Cheung, J; Dey, D; McSweeney, C; Morrison, M; Kobayashi, Y; Whitman, W B; Carbone, V; Schofield, L R; Ronimus, R S; Cook, G M

    2017-08-01

    Hydrogenotrophic methanogens typically require strictly anaerobic culturing conditions in glass tubes with overpressures of H 2 and CO 2 that are both time-consuming and costly. To increase the throughput for screening chemical compound libraries, 96-well microtiter plate methods for the growth of a marine (environmental) methanogen Methanococcus maripaludis strain S2 and the rumen methanogen Methanobrevibacter species AbM4 were developed. A number of key parameters (inoculum size, reducing agents for medium preparation, assay duration, inhibitor solvents, and culture volume) were optimized to achieve robust and reproducible growth in a high-throughput microtiter plate format. The method was validated using published methanogen inhibitors and statistically assessed for sensitivity and reproducibility. The Sigma-Aldrich LOPAC library containing 1,280 pharmacologically active compounds and an in-house natural product library (120 compounds) were screened against M. maripaludis as a proof of utility. This screen identified a number of bioactive compounds, and MIC values were confirmed for some of them against M. maripaludis and M. AbM4. The developed method provides a significant increase in throughput for screening compound libraries and can now be used to screen larger compound libraries to discover novel methanogen-specific inhibitors for the mitigation of ruminant methane emissions. IMPORTANCE Methane emissions from ruminants are a significant contributor to global greenhouse gas emissions, and new technologies are required to control emissions in the agriculture technology (agritech) sector. The discovery of small-molecule inhibitors of methanogens using high-throughput phenotypic (growth) screening against compound libraries (synthetic and natural products) is an attractive avenue. However, phenotypic inhibitor screening is currently hindered by our inability to grow methanogens in a high-throughput format. We have developed, optimized, and validated a high-throughput 96-well microtiter plate assay for growing environmental and rumen methanogens. Using this platform, we identified several new inhibitors of methanogen growth, demonstrating the utility of this approach to fast track the development of methanogen-specific inhibitors for controlling ruminant methane emissions. Copyright © 2017 American Society for Microbiology.

  20. New-type planar field emission display with superaligned carbon nanotube yarn emitter.

    PubMed

    Liu, Peng; Wei, Yang; Liu, Kai; Liu, Liang; Jiang, Kaili; Fan, Shoushan

    2012-05-09

    With the superaligned carbon nanotube yarn as emitter, we have fabricated a 16 × 16 pixel field emission display prototype by adopting screen printing and laser cutting technologies. A planar diode field emission structure has been adopted. A very sharp carbon nanotube yarn tip emitter can be formed by laser cutting. Low voltage phosphor was coated on the anode electrodes also by screen printing. With a specially designed circuit, we have demonstrated the dynamic character display with the field emission display prototype. The emitter material and fabrication technologies in this paper are both easy to scale up to large areas.

  1. Rapid methodology to screen flame retardants in upholstered furniture for compliance with new California labeling law (SB 1019).

    PubMed

    Petreas, Myrto; Gill, Ranjit; Takaku-Pugh, Sayaka; Lytle, Eric; Parry, Emily; Wang, Miaomiao; Quinn, John; Park, June-Soo

    2016-06-01

    In response to concerns regarding the widespread use of flame retardants, the California Legislature passed a law (SB1019) requiring labels on furniture products to indicate whether they do or do not contain flame retardants. To support the enforcement of the new law, our laboratory developed a step-wise, screening approach to test for brominated (BFR) and phosphorus-based flame retardants (OPFRs) in several types of furniture components (foam, fabric, batting, plumage, etc.). We used X-Ray Fluorescence (XRF) to screen for the presence of Br (and other elements) and Inductively Coupled Plasma - Optical Emission Spectrometry (ICP-OES) to identify and measure the concentration of P (and other elements). The same samples were also extracted by dichloromethane using sonication and analyzed by a single injection into a Gas Chromatograph - Tandem Mass Spectrometer to obtain concentrations of specific BFRs and OPFRs. Our approach showed excellent screening potential for Br and Sb by XRF and for P by ICP-OES, with both tests having predictive values of a negative equal to 1. To explore and screen for flame retardants in products not included in our current list of target chemicals, we used Liquid Chromatography/Time-of-Flight Mass Spectrometry operated with electrospray ionization, to identify additional flame retardants to be incorporated in quantitative methods. We are making all our methodologies public to facilitate simple and low cost methods that can help manufacturers and suppliers have their products tested and correctly labeled, ultimately benefitting the consumer. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. [Audiological characteristics of young children with otitis media with effusion].

    PubMed

    Wang, Qiu-ju; Shi, Wei; Lan, Lan; Wang, Da-yong; Zhang, Ya-mei

    2008-12-01

    To characterize the audiological features in the infants with otitis media with effusion (OME) and to investigate the utility of variety of objective audiometry methods in diagnosis and intervention on OME. Fifty six infants (40 males and 16 females) were investigated, who were referred to our clinic at the General Hospital of Chinese People's Liberation Army by the other hospitals from December 2004 to June 2007 when the infants were diagnosed or highly suspected of OME. The ages at the initial diagnosis ranged from 42 days to three years, with an average of five months. The infants, after receiving the conventional otolaryngological exams, were subjected to the tests of auditory brainstem response (ABR), otoacoustic emission (OAE), tympanometry (226 Hz and 1000 Hz) and behaviors audiometry. Among 56 affected infants, 87 ears were diagnosed with OME, of which 31 infants were affected bilateral and 25 with monaural. For the 49 infants who received hearing screening at birth, 36 infants were referred at the initial screening. For the 52 infants who received repeated screening, all subjects were referred. Six infants without receiving hearing screening came to clinic when their parents observed their kids' hearing impairment. Among the 52 cases (104 ears) who received tympanometry test, 20 subjects (28 ears) showed B or C type tympanometry curve. Thirty-nine cases (78 ears) were given tympanometry test at 1000 Hz, of which 38 cases (55 ears) showed abnormal hearing. Among 56 infants (112 ears) with ABR test, 49 subjects (74 ears) exhibited prolonged ABR type I curve. All 56 infants (112 ears) received OAE test, of which 55 subjects (81 ears) were referred. Four infants (8 ears) accepted the behavior test and all of them showed A-B Gap. The combined tympanometry test at both 226 Hz and 1000 Hz, ABR latency or threshold test, infant's behavior test and OAE, used jointly, enable characterizing better OME in infants, thus helping early diagnosis of this hearing disorder.

  3. Otoacoustic emissions in the general adult population of Nord-Trøndelag, Norway: III. Relationships with pure-tone hearing thresholds.

    PubMed

    Engdahl, Bo; Tambs, Kristian; Borchgrevink, Hans M; Hoffman, Howard J

    2005-01-01

    This study aims to describe the association between otoacoustic emissions (OAEs) and pure-tone hearing thresholds (PTTs) in an unscreened adult population (N =6415), to determine the efficiency by which TEOAEs and DPOAEs can identify ears with elevated PTTs, and to investigate whether a combination of DPOAE and TEOAE responses improves this performance. Associations were examined by linear regression analysis and ANOVA. Test performance was assessed by receiver operator characteristic (ROC) curves. The relation between OAEs and PTTs appeared curvilinear with a moderate degree of non-linearity. Combining DPOAEs and TEOAEs improved performance. Test performance depended on the cut-off thresholds defining elevated PTTs with optimal values between 25 and 45 dB HL, depending on frequency and type of OAE measure. The unique constitution of the present large sample, which reflects the general adult population, makes these results applicable to population-based studies and screening programs.

  4. Assessment of a landfill methane emission screening method using an unmanned aerial vehicle mounted thermal infrared camera - A field study.

    PubMed

    Fjelsted, L; Christensen, A G; Larsen, J E; Kjeldsen, P; Scheutz, C

    2018-05-28

    An unmanned aerial vehicle (UAV)-mounted thermal infrared (TIR) camera's ability to delineate landfill gas (LFG) emission hotspots was evaluated in a field test at two Danish landfills (Hedeland landfill and Audebo landfill). At both sites, a test area of 100 m 2 was established and divided into about 100 measuring points. The relationship between LFG emissions and soil surface temperatures were investigated through four to five measuring campaigns, in order to cover different atmospheric conditions along with increasing, decreasing and stable barometric pressure. For each measuring campaign, a TIR image of the test area was obtained followed by the measurement of methane (CH 4 ) and carbon dioxide (CO 2 ) emissions at each measuring point, using a static flux chamber. At the same time, soil temperatures measured on the surface, at 5 cm and 10 cm depths, were registered. At the Hedeland landfill, no relationship was found between LFG emissions and surface temperatures. In addition, CH 4 emissions were very limited, on average 0.92-4.52 g CH 4  m -2  d -1 , and only measureable on the two days with decreasing barometric pressure. TIR images from Hedeland did not show any significant temperature differences in the test area. At the Audebo landfill, an area with slightly higher surface temperatures was found in the TIR images, and the same pattern with slightly higher temperatures was found at a depth of 10 cm. The main LFG emissions were found in the area with the higher surface temperatures. LFG emissions at Audebo were influenced significantly by changes in barometric pressure, and the average CH 4 emissions varied between 111 g m -2  d -1 and 314 g m -2  d -1 , depending on whether the barometric pressure gradient had increased or decreased, respectively. The temperature differences observed in the TIR images from both landfills were limited to between 0.7 °C and 1.2 °C. The minimum observable CH 4 emission for the TIR camera to identify an emission hotspot was 150 g CH 4  m -2  d -1 from an area of more than 1 m 2 . Copyright © 2018 Elsevier Ltd. All rights reserved.

  5. Methods of editing cloud and atmospheric layer affected pixels from satellite data

    NASA Technical Reports Server (NTRS)

    Nixon, P. R. (Principal Investigator); Wiegand, C. L.; Richardson, A. J.; Johnson, M. P.; Goodier, B. G.

    1981-01-01

    The location and migration of cloud, land and water features were examined in spectral space (reflective VIS vs. emissive IR). Daytime HCMM data showed two distinct types of cloud affected pixels in the south Texas test area. High altitude cirrus and/or cirrostratus and "subvisible cirrus" (SCi) reflected the same or only slightly more than land features. In the emissive band, the digital counts ranged from 1 to over 75 and overlapped land features. Pixels consisting of cumulus clouds, or of mixed cumulus and landscape, clustered in a different area of spectral space than the high altitude cloud pixels. Cumulus affected pixels were more reflective than land and water pixels. In August the high altitude clouds and SCi were more emissive than similar clouds were in July. Four-channel TIROS-N data were examined with the objective of developing a multispectral screening technique for removing SCi contaminated data.

  6. VOLATILE ORGANIC COMPOUNDS FROM VEGETATION IN SOUTHERN YUNNAN PROVINCE, CHINA: EMISSION RATES AND SOME POTENTIAL REGIONAL IMPLICATIONS

    EPA Science Inventory

    Little information is currently available regarding emissions of biogenic volatile organic compounds (BVOCs) in southern Asia. To address the need for BVOC emission estimates in regional atmospheric chemistry simulations, 95 common plant species were screened for emissions of BVO...

  7. Increasing sensitivity of methane emission measurements in rice through deployment of ‘closed chambers’ at nighttime

    PubMed Central

    Wassmann, Reiner; Alberto, Ma. Carmelita; Tirol-Padre, Agnes; Hoang, Nghia Trong; Romasanta, Ryan; Centeno, Caesar Arloo; Sander, Bjoern Ole

    2018-01-01

    This study comprises field experiments on methane emissions from rice fields conducted with an Eddy-Covariance (EC) system as well as test runs for a modified closed chamber approach based on measurements at nighttime. The EC data set covers 4 cropping seasons with highly resolved emission rates (raw data in 10 Hz frequency have been aggregated to 30-min records). The diel patterns were very pronounced in the two dry seasons with peak emissions at early afternoon and low emissions at nighttime. These diel patterns were observed at all growing stages of the dry seasons. In the two wet seasons, the diel patterns were only visible during the vegetative stages while emission rates during reproductive and ripening stages remained within a fairly steady range and did not show any diel patterns. In totality, however, the data set revealed a very strong linear relationship between nocturnal emissions (12-h periods) and the full 24-h periods resulting in an R2-value of 0.8419 for all data points. In the second experiment, we conducted test runs for chamber measurements at nighttime with much longer deployment times (6 h) as compared to measurements at daylight (typically for 30 min). Conducting chamber measurements at nighttime excluded drastic changes of temperatures and CO2 concentrations. The data also shows that increases in CH4 concentrations remained on linear trajectory over a 6h period at night. While end CH4 concentrations were consistently >3.5 ppm, this long-term enclosure represents a very robust approach to quantify emissions as compared to assessing short-term concentration increases over time near the analytical detection limit. Finally, we have discussed the potential applications of this new approach that would allow emission measurements even when conventional (daytime) measurements will not be suitable. Nighttime chamber measurements offer an alternative to conventional (daytime) measurements if either (i) baseline emissions are at a very low level, (ii) differences of tested crop treatments or varieties are very small or (iii) the objective is to screen a large number of rice varieties for taking advantage of progress in genome sequencing. PMID:29390000

  8. Secondary Organic Aerosol Production from Gasoline Vehicle Exhaust: Effects of Engine Technology, Cold Start, and Emission Certification Standard.

    PubMed

    Zhao, Yunliang; Lambe, Andrew T; Saleh, Rawad; Saliba, Georges; Robinson, Allen L

    2018-02-06

    Secondary organic aerosol (SOA) formation from dilute exhaust from 16 gasoline vehicles was investigated using a potential aerosol mass (PAM) oxidation flow reactor during chassis dynamometer testing using the cold-start unified cycle (UC). Ten vehicles were equipped with gasoline direct injection engines (GDI vehicles) and six with port fuel injection engines (PFI vehicles) certified to a wide range of emissions standards. We measured similar SOA production from GDI and PFI vehicles certified to the same emissions standard; less SOA production from vehicles certified to stricter emissions standards; and, after accounting for differences in gas-particle partitioning, similar effective SOA yields across different engine technologies and certification standards. Therefore the ongoing, dramatic shift from PFI to GDI vehicles in the United States should not alter the contribution of gasoline vehicles to ambient SOA and the natural replacement of older vehicles with newer ones certified to stricter emissions standards should reduce atmospheric SOA levels. Compared to hot operations, cold-start exhaust had lower effective SOA yields, but still contributed more SOA overall because of substantially higher organic gas emissions. We demonstrate that the PAM reactor can be used as a screening tool for vehicle SOA production by carefully accounting for the effects of the large variations in emission rates.

  9. Measurement environments and testing

    NASA Astrophysics Data System (ADS)

    Marvin, A. C.

    1991-06-01

    The various methods used to assess both the emission (interference generation) performance of electronic equipment and the immunity of electronic equipment to external electromagnetic interference are described. The measurement methods attempt to simulate realistic operating conditions for the equipment being tested, yet at the same time they must be repeatable and practical to operate. This has led to the development of a variety of test methods, each of which has its limitations. Concentration is on the most common measurement methods such as open-field test sites, screened enclosures and transverse electromagnetic (TEM) cells. The physical justification for the methods, their limitations, and measurement precision are described. Ways of relating similar measurements made by different methods are discussed, and some thoughts on future measurement improvements are presented.

  10. Hearing loss among high-risk newborns admitted to a tertiary Neonatal Intensive Care Unit.

    PubMed

    Khairy, May Ahmed; Abuelhamed, Walaa Alsharany; Ahmed, Radwa Sayed; El Fouly, Hedayet El Sayed; Elhawary, Ismail Mohamed

    2018-07-01

    The aim of this work is to identify the most significant risk factors for hearing impairment in high risk neonates hospitalized at our Neonatal Intensive Care Unit (NICU) and to assess the sensitivity of hearing screening tests. This study involved 260 neonates admitted to a tertiary NICU; they were classified into two groups; 150 preterm and 110 full terms with risk factors for hearing loss. The hearing screening tests performed were transient evoked otoacoustic emissions (TEOAEs) and the automated auditory brainstem response (AABR). Forty-eight preterm neonates (32%) and 30 full term neonates (27.3%) had pathological AABR. In preterm group, mechanical ventilation more than five days, sepsis, usage of aminoglycosides, loop diuretics, vancomycin alone or in combination with aminoglycosides and prolonged duration of admission were considered risk factors of hearing affection whereas in full term group mechanical ventilation more than five days was the risk factor of hearing affection (p<.05). The prevalence of hearing loss is highest among high risk neonates and TEOAE and AABR were found to be reliable screening tools. Use of ototoxic drugs and mechanical ventilation for more than five days were significant risk factors for hearing loss in our study population.

  11. The hearing system in newborns from the Upper Silesia. Assessment of TEOAE depending on selected parameters of delivery disorders.

    PubMed

    Namyslowski, G; Morawski, K; Urbaniec, N; Lisowska, G; Trybalska, G; Bazowska, G; Oslislo, A

    2001-01-01

    Transient evoked otoacoustic emission (TEOAE) is an accepted test for screening of the cochlea function in newborns. In this study 300 newborns was tested using TEOAE, as well as analysing such parameters as birth weight, Apgar scale, bilirubinaemia. The study indicated the tendency of TEOAE to decrease in newborns with low birth weight and low Apgar scores. Hyperbilirubinaemia seems to have an influence on cochlea function monitored by TEOAE, especially if there were simultaneously low Apgar scores. A similar tendency, although slightly stronger, was observed in the preterm newborn group. TEOAE seems to be a good method of recording the negative influence on the cochlea activity such factors as low birth weight and asphyxia. Hyperbilirubinaemia with asphyxia acts upon the cochlea similarly. All these tendencies were observed more strongly in the preterm newborn group. It is concluded that TEOAE analysis demonstrated its utility as a screening test assessing the hearing state in newborns, additionally the associations of cochlea activity was found with a few parameters of delivery disorders.

  12. Junction-based field emission structure for field emission display

    DOEpatents

    Dinh, Long N.; Balooch, Mehdi; McLean, II, William; Schildbach, Marcus A.

    2002-01-01

    A junction-based field emission display, wherein the junctions are formed by depositing a semiconducting or dielectric, low work function, negative electron affinity (NEA) silicon-based compound film (SBCF) onto a metal or n-type semiconductor substrate. The SBCF can be doped to become a p-type semiconductor. A small forward bias voltage is applied across the junction so that electron transport is from the substrate into the SBCF region. Upon entering into this NEA region, many electrons are released into the vacuum level above the SBCF surface and accelerated toward a positively biased phosphor screen anode, hence lighting up the phosphor screen for display. To turn off, simply switch off the applied potential across the SBCF/substrate. May be used for field emission flat panel displays.

  13. High-alcohol microemulsion fuel performance in a diesel engine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    West, B.H.; Compere, A.L.; Griffith, W.L.

    1990-01-01

    Incidence of methanol use in diesel engines is increasing rapidly due to the potential to reduce both diesel particulate emissions and petroleum consumption. Because simple alcohols and conventional diesel fuel are normally immiscible, most tests to date have used neat to near-neat alcohol, or blends incorporating surfactants or other alcohols. Alcohol's poor ignition quality usually necssitates the use of often expensive cetane enhancers, full-time glow plugs, or spark assist. Reported herein are results of screening tests of clear microemulsion and micellar fuels which contain 10 to 65% C{sub 1}--C{sub 4} alcohol. Ignition performance and NO emissions were measured for clear,more » stable fuel blends containing alcohols, diesel fuel and additives such as alkyl nitrates, acrylic acids, and several vegetable oil derivatives. Using a diesel engine calibrated with reference fuels, cetane numbers for fifty four blends were estimated. The apparent cetane numbers ranged from around 20 to above 50 with the majority between 30 and 45. Emissions of nitric oxide were measured for a few select fuels and were found to be 10 to 20% lower than No. 2 diesel fuel. 36 refs., 87 figs., 8 tabs.« less

  14. [Diagnostic work-up of pulmonary nodules : Management of pulmonary nodules detected with low‑dose CT screening].

    PubMed

    Wormanns, D

    2016-09-01

    Pulmonary nodules are the most frequent pathological finding in low-dose computed tomography (CT) scanning for early detection of lung cancer. Early stages of lung cancer are often manifested as pulmonary nodules; however, the very commonly occurring small nodules are predominantly benign. These benign nodules are responsible for the high percentage of false positive test results in screening studies. Appropriate diagnostic algorithms are necessary to reduce false positive screening results and to improve the specificity of lung cancer screening. Such algorithms are based on some of the basic principles comprehensively described in this article. Firstly, the diameter of nodules allows a differentiation between large (>8 mm) probably malignant and small (<8 mm) probably benign nodules. Secondly, some morphological features of pulmonary nodules in CT can prove their benign nature. Thirdly, growth of small nodules is the best non-invasive predictor of malignancy and is utilized as a trigger for further diagnostic work-up. Non-invasive testing using positron emission tomography (PET) and contrast enhancement as well as invasive diagnostic tests (e.g. various procedures for cytological and histological diagnostics) are briefly described in this article. Different nodule morphology using CT (e.g. solid and semisolid nodules) is associated with different biological behavior and different algorithms for follow-up are required. Currently, no obligatory algorithm is available in German-speaking countries for the management of pulmonary nodules, which reflects the current state of knowledge. The main features of some international and American recommendations are briefly presented in this article from which conclusions for the daily clinical use are derived.

  15. Leaf level emissions of volatile organic compounds (VOC) from some Amazonian and Mediterranean plants

    NASA Astrophysics Data System (ADS)

    Bracho-Nunez, A.; Knothe, , N. M.; Welter, S.; Staudt, M.; Costa, W. R.; Liberato, M. A. R.; Piedade, M. T. F.; Kesselmeier, J.

    2013-09-01

    Emission inventories defining regional and global biogenic volatile organic compounds (VOC) emission strengths are needed to determine the impact of VOC on atmospheric chemistry (oxidative capacity) and physics (secondary organic aerosol formation and effects). The aim of this work was to contribute with measurements of tree species from the poorly described tropical vegetation in direct comparison with the quite well-investigated, highly heterogeneous emissions from Mediterranean vegetation. VOC emission from sixteen plant species from the Mediterranean area were compared with twelve plant species from different environments of the Amazon basin by an emission screening at leaf level using branch enclosures. Analysis of the volatile organics was performed online by a proton-transfer-reaction mass spectrometer (PTR-MS) and offline by collection on adsorbent tubes and subsequent gas chromatographic analysis. Isoprene was the most dominant compound emitted followed by monoterpenes, methanol and acetone. The average loss rates of VOC carbon in relation to the net CO2 assimilation were found below 4% and indicating normal unstressed plant behavior. Most of the Mediterranean species emitted a large variety of monoterpenes, whereas only five tropical species were identified as monoterpene emitters exhibiting a quite conservative emission pattern (α-pinene < limonene < sabinene < ß-pinene). Mediterranean plants showed additional emissions of sesquiterpenes. In the case of Amazonian plants no sesquiterpenes were detected. However, missing of sesquiterpenes may also be due to a lack of sensitivity of the measuring systems. Furthermore, our screening activities cover only 1% of tree species of such tropical areas as estimated based on recent biodiversity reports. Methanol emissions, an indicator of growth, were found to be common in most of the tropical and Mediterranean species. A few species from both ecosystems showed acetone emissions. The observed heterogeneous emissions, including reactive VOC species which are not easily detected by flux measurements, give reason to perform more screening at leaf level and, whenever possible, within the forests under ambient conditions.

  16. Silver Nanoscale Hexagonal Column Chips for Detecting Cell-free DNA and Circulating Nucleosomes in Cancer Patients.

    PubMed

    Ito, Hiroaki; Hasegawa, Katsuyuki; Hasegawa, Yuuki; Nishimaki, Tadashi; Hosomichi, Kazuyoshi; Kimura, Satoshi; Ohba, Motoi; Yao, Hiroshi; Onimaru, Manabu; Inoue, Ituro; Inoue, Haruhiro

    2015-05-21

    Blood tests, which are commonly used for cancer screening, generally have low sensitivity. Here, we developed a novel rapid and simple method to generate silver nanoscale hexagonal columns (NHCs) for use in surface-enhanced Raman scattering (SERS). We reported that the intensity of SERS spectra of clinical serum samples obtained from gastrointestinal cancer patients is was significantly higher than that of SERS spectra of clinical serum samples obtained from non-cancer patients. We estimated the combined constituents on silver NHCs by using a field emission-type scanning electron microscope, Raman microscopes, and a 3D laser scanning confocal microscope. We obtained the Raman scattering spectra of samples of physically fractured cells and clinical serum. No spectra were obtained for chemically lysed cultured cells and DNA, RNA, and protein extracted from cultured cells. We believe that our method, which uses SERS with silver NHCs to detect circulating nucleosomes bound by methylated cell-free DNA, may be successfully implemented in blood tests for cancer screening.

  17. Screening level risk assessment model for chemical fate and effects in the environment.

    PubMed

    Arnot, Jon A; Mackay, Don; Webster, Eva; Southwood, Jeanette M

    2006-04-01

    A screening level risk assessment model is developed and described to assess and prioritize chemicals by estimating environmental fate and transport, bioaccumulation, and exposure to humans and wildlife for a unit emission rate. The most sensitive risk endpoint is identified and a critical emission rate is then calculated as a result of that endpoint being reached. Finally, this estimated critical emission rate is compared with the estimated actual emission rate as a risk assessment factor. This "back-tracking" process avoids the use of highly uncertain emission rate data as model input. The application of the model is demonstrated in detail for three diverse chemicals and in less detail for a group of 70 chemicals drawn from the Canadian Domestic Substances List. The simple Level II and the more complex Level III fate calculations are used to "bin" substances into categories of similar probable risk. The essential role of the model is to synthesize information on chemical and environmental properties within a consistent mass balance framework to yield an overall estimate of screening level risk with respect to the defined endpoint. The approach may be useful to identify and prioritize those chemicals of commerce that are of greatest potential concern and require more comprehensive modeling and monitoring evaluations in actual regional environments and food webs.

  18. Optical photon transport in powdered-phosphor scintillators. Part II. Calculation of single-scattering transport parameters

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Poludniowski, Gavin G.; Evans, Philip M.

    2013-04-15

    Purpose: Monte Carlo methods based on the Boltzmann transport equation (BTE) have previously been used to model light transport in powdered-phosphor scintillator screens. Physically motivated guesses or, alternatively, the complexities of Mie theory have been used by some authors to provide the necessary inputs of transport parameters. The purpose of Part II of this work is to: (i) validate predictions of modulation transform function (MTF) using the BTE and calculated values of transport parameters, against experimental data published for two Gd{sub 2}O{sub 2}S:Tb screens; (ii) investigate the impact of size-distribution and emission spectrum on Mie predictions of transport parameters; (iii)more » suggest simpler and novel geometrical optics-based models for these parameters and compare to the predictions of Mie theory. A computer code package called phsphr is made available that allows the MTF predictions for the screens modeled to be reproduced and novel screens to be simulated. Methods: The transport parameters of interest are the scattering efficiency (Q{sub sct}), absorption efficiency (Q{sub abs}), and the scatter anisotropy (g). Calculations of these parameters are made using the analytic method of Mie theory, for spherical grains of radii 0.1-5.0 {mu}m. The sensitivity of the transport parameters to emission wavelength is investigated using an emission spectrum representative of that of Gd{sub 2}O{sub 2}S:Tb. The impact of a grain-size distribution in the screen on the parameters is investigated using a Gaussian size-distribution ({sigma}= 1%, 5%, or 10% of mean radius). Two simple and novel alternative models to Mie theory are suggested: a geometrical optics and diffraction model (GODM) and an extension of this (GODM+). Comparisons to measured MTF are made for two commercial screens: Lanex Fast Back and Lanex Fast Front (Eastman Kodak Company, Inc.). Results: The Mie theory predictions of transport parameters were shown to be highly sensitive to both grain size and emission wavelength. For a phosphor screen structure with a distribution in grain sizes and a spectrum of emission, only the average trend of Mie theory is likely to be important. This average behavior is well predicted by the more sophisticated of the geometrical optics models (GODM+) and in approximate agreement for the simplest (GODM). The root-mean-square differences obtained between predicted MTF and experimental measurements, using all three models (GODM, GODM+, Mie), were within 0.03 for both Lanex screens in all cases. This is excellent agreement in view of the uncertainties in screen composition and optical properties. Conclusions: If Mie theory is used for calculating transport parameters for light scattering and absorption in powdered-phosphor screens, care should be taken to average out the fine-structure in the parameter predictions. However, for visible emission wavelengths ({lambda} < 1.0 {mu}m) and grain radii (a > 0.5 {mu}m), geometrical optics models for transport parameters are an alternative to Mie theory. These geometrical optics models are simpler and lead to no substantial loss in accuracy.« less

  19. NC-TEST: noncontact thermal emissions screening technique for drug and alcohol detection

    NASA Astrophysics Data System (ADS)

    Prokoski, Francine J.

    1997-01-01

    Drug abuse is highly correlated with criminal behavior. The typical drug-using criminal commits hundreds of crimes per year. The crime rate cannot be significantly reduced without a reduction in the percentage of the population abusing drugs and alcohol. Accurate and timely estimation of that percentage is important for policy decisions concerning crime control, public health measures, allocation of intervention resources for prevention and treatment, projections of criminal justice needs, and the evaluation of policy effectiveness. Such estimation is particularly difficult because self reporting is unreliable; and physical testing has to date required blood or urine analysis which is expensive and invasive, with the result that too few people are tested. MIKOS Ltd. has developed a non-contact, passive technique with the potential for automatic, real- time screening for drug and alcohol use. The system utilizes thermal radiation which is spontaneously and continuously emitted by the human body. Facial thermal patterns and changes in patterns are correlated with standardized effects of specific drugs and alcohol. A portable system incorporating the collection and analysis technique can be used episodically to collect data for estimating drug and alcohol use by general unknown populations such as crowds at airports, or it can be used for repetitive routine screening of specific known groups such as airline pilots, military personnel, school children, or persons on probation or parole.

  20. APPLICATION OF POLLUTION PREVENTION TECHNIQUES TO REDUCE INDOOR AIR EMISSIONS FROM ENGINEERED WOOD PRODUCTS

    EPA Science Inventory

    The report gives results of an investigation of pollution prevention options to reduce indoor emissions from a type of finished engineered wood. Emissions were screened from four types of finished engineered wood: oak-veneered particleboard coated and cured with a heat-curable, a...

  1. Results of an early hearing detection program.

    PubMed

    Borkoski Barreiro, Silvia A; Falcón González, Juan C; Bueno Yanes, Jorge; Pérez Bermúdez, José L; López Cano, Zoraida; Ramos Macías, Ángel

    2013-01-01

    Neonatal hearing loss is a public health problem that meets the requirements for submission to universal screening. Our objective was to analyse the results of the early hearing detection and intervention program implemented at our centre between January 2007 and December 2010. We studied 26,717 newborns during the period mentioned, using transient otoacoustic emissions (TOAEs) for the screening. The diagnostic phase was carried out at the hearing loss department. In our area, there were 27,935 births between January 2007 and December 2010. The screening was performed on 26,717 children. Of these, 24,173 had positive TOAEs, 1,040 had no TOAEs and 1,504 presented TOAEs in 1 ear with absence of TOAEs in the contralateral ear. Risk factors associated with hearing loss were found in 4,674 infants. In a second phase of the program, TOAEs were given to 5,156 children, of whom 4,626 had positive otoacoustic emissions in both ears, 323 had no TOAEs in 1 ear and 207 failed this second phase. Of all children studied, 3.8% were referred to auditory brainstem response (ABR) testing and 26 children entered the cochlear implant program. The program reached coverage of 95.64%. The early hearing detection and intervention program at our hospital is suitable for our environment, reaching 95.64% of coverage. We consider the relationship between effectiveness and efficiency to be positive. Copyright © 2012 Elsevier España, S.L. All rights reserved.

  2. DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    The objective of Task I is to prepare and evaluate catalysts and to develop efficient reactor systems for the selective conversion of hydrogen-lean synthesis gas to alcohol fuel extenders and octane enhancers. In Task 1, during this reporting period, we encountered and solved a problem in the analysis of the reaction products containing a small amount of heavy components. Subsequently, we continued with the major thrusts of the program. We analyzed the results from our preliminary studies on the packed-bed membrane reactor using the BASF methanol synthesis catalyst. We developed a quantitative model to describe the performance of the reactor.more » The effect of varying permeances and the effect of catalyst aging are being incorporated into the model. Secondly, we resumed our more- detailed parametric studies on selected non-sulfide Mo-based catalysts. Finally, we continue with the analysis of data from the kinetic study of a sulfided carbon-supported potassium-doped molybdenum-cobalt catalyst in the Rotoberty reactor. We have completed catalyst screening at UCC. The complete characterization of selected catalysts has been started. In Task 2, the fuel blends of alcohol and unleaded test gas 96 (UTG 96) have been made and tests have been completed. The testing includes knock resistance tests and emissions tests. Emissions tests were conducted when the engine was optimized for the particular blend being tested (i.e. where the engine produced the most power when running on the blend in question). The data shows that the presence of alcohol in the fuel increases the fuel`s ability to resist knock. Because of this, when the engine was optimized for use with alcohol blends, the engine produced more power and lower emission rates.« less

  3. [Newborn hearing screening program: association between hearing loss and risk factors].

    PubMed

    Pereira, Priscila Karla Santana; Martins, Adriana de Souza; Vieira, Márcia Ribeiro; Azevedo, Marisa Frasson de

    2007-01-01

    Hearing loss in newborns. To verify the prevalence of auditory alterations in newborns of Hospital São Paulo (hospital), observing if there are any correlations with the following variables: birth weight, gestational age, relation weight/gestational age and risk factors for hearing loss. A retrospective analysis of the hospital records of 1696 newborns; 648 records of preterm infants and 1048 records of infants born at term. All of the infants had been submitted to an auditory evaluation consisting of: Transient Otoacoustic Emissions, investigation of the cochleal-palpebral reflexes and acoustic imittance tests, identifying the type and level of hearing loss. Sensorineural hearing loss was identified in .82% of the infants who were born at term and in 3.1% of the preterm infants -- with a statistically significant difference. Conductive hearing loss was the most frequent type of hearing loss in both groups, occurring in 14.6% of the term infants and in 16.3% of the preterm infants. Alteration of the central auditory system was considered as a possible diagnosis for 5.8% of the preterm infants and for 3.3% of the term infants. For the group of infants who were born at term, a significant correlation was observed between failure in the hearing screening test and the presence of risk factors such as family history and presence of a syndrome -- the child who presented a syndrome had 37 times more chances of failing in the hearing screening test and seven times more chances of failing in the right ear when there was a family history for hearing loss. The lower the gestational age (< 30 weeks) and birth weight (< 1500 g), the higher the chances of failing in the hearing screening test (3 times more). Hearing loss had a higher occurrence in preterm infants who remained in the ICU. Gestational age and birth weight were important variables related to the possibility of failure in the hearing screening test. A correlation was observed between the presence of a syndrome and sensorineural hearing loss in infants who were born at term.

  4. Emissions of Ultrafine Particles and Volatile Organic Compounds from Commercially Available Desktop Three-Dimensional Printers with Multiple Filaments.

    PubMed

    Azimi, Parham; Zhao, Dan; Pouzet, Claire; Crain, Neil E; Stephens, Brent

    2016-02-02

    Previous research has shown that desktop 3D printers can emit large numbers of ultrafine particles (UFPs, particles less than 100 nm) and some hazardous volatile organic compounds (VOCs) during printing, although very few filament and 3D printer combinations have been tested to date. Here we quantify emissions of UFPs and speciated VOCs from five commercially available filament extrusion desktop 3D printers utilizing up to nine different filaments by controlled experiments in a test chamber. Median estimates of time-varying UFP emission rates ranged from ∼10(8) to ∼10(11) min(-1) across all tested combinations, varying primarily by filament material and, to a lesser extent, bed temperature. The individual VOCs emitted in the largest quantities included caprolactam from nylon-based and imitation wood and brick filaments (ranging from ∼2 to ∼180 μg/min), styrene from acrylonitrile butadiene styrene (ABS) and high-impact polystyrene (HIPS) filaments (ranging from ∼10 to ∼110 μg/min), and lactide from polylactic acid (PLA) filaments (ranging from ∼4 to ∼5 μg/min). Results from a screening analysis of potential exposure to these products in a typical small office environment suggest caution should be used when operating many of the printer and filament combinations in poorly ventilated spaces or without the aid of combined gas and particle filtration systems.

  5. Charge transfer optical absorption and fluorescence emission of 4-(9-acridyl)julolidine from long-range-corrected time dependent density functional theory in polarizable continuum approach.

    PubMed

    Kityk, A V

    2014-07-15

    A long-range-corrected time-dependent density functional theory (LC-TDDFT) in combination with polarizable continuum model (PCM) have been applied to study charge transfer (CT) optical absorption and fluorescence emission energies basing on parameterized LC-BLYP xc-potential. The molecule of 4-(9-acridyl)julolidine selected for this study represents typical CT donor-acceptor dye with strongly solvent dependent optical absorption and fluorescence emission spectra. The result of calculations are compared with experimental spectra reported in the literature to derive an optimal value of the model screening parameter ω. The first absorption band appears to be quite well predictable within DFT/TDDFT/PCM with the screening parameter ω to be solvent independent (ω ≈ 0.245 Bohr(-1)) whereas the fluorescence emission exhibits a strong dependence on the range separation with ω-value varying on a rising solvent polarity from about 0.225 to 0.151 Bohr(-1). Dipolar properties of the initial state participating in the electronic transition have crucial impact on the effective screening. Copyright © 2014 Elsevier B.V. All rights reserved.

  6. [Evaluation of otoacoustic emissions in relation to brainstem evoked auditory potentials in children].

    PubMed

    Rado-Triveño, Julia; Alen-Ayca, Jaime

    2016-01-01

    To determine the validity of the use of acoustic otoacoustic emissions in comparison with the evoked potentials Auditory brainstem examination (PEATC), a study was carried out with 96 children between 0 and 4 years of age that went to Instituto Nacional de Rehabilitación in Lima, Peru. The results show a cut-off point corresponding to 1 in (+): 17.67 in right ear and 16.72 in left ear, and LR (-): 0.25 in ear right and 0.24 in left ear; ROC curve with area under the right ear curve of 0.830 (p<0.001) was obtained and in left ear of 0.829 (p<0.001). According to the results of LR (+) the sensitivity is 76% in the right ear and 65% In the left ear that coincides with the conformation of the ROC curve. In conclusion, acoustic emissions would not represent an alternative sufficiently discriminatory alternative as a screening test in this population.

  7. School Locations and Traffic Emissions — Environmental (In)Justice Findings Using a New Screening Method

    PubMed Central

    Gaffron, Philine; Niemeier, Deb

    2015-01-01

    It has been shown that the location of schools near heavily trafficked roads can have detrimental effects on the health of children attending those schools. It is therefore desirable to screen both existing school locations and potential new school sites to assess either the need for remedial measures or suitability for the intended use. Current screening tools and public guidance on school siting are either too coarse in their spatial resolution for assessing individual sites or are highly resource intensive in their execution (e.g., through dispersion modeling). We propose a new method to help bridge the gap between these two approaches. Using this method, we also examine the public K-12 schools in the Sacramento Area Council of Governments Region, California (USA) from an environmental justice perspective. We find that PM2.5 emissions from road traffic affecting a school site are significantly positively correlated with the following metrics: percent share of Black, Hispanic and multi-ethnic students, percent share of students eligible for subsidized meals. The emissions metric correlates negatively with the schools’ Academic Performance Index, the share of White students and average parental education levels. Our PM2.5 metric also correlates with the traffic related, census tract level screening indicators from the California Communities Environmental Health Screening Tool and the tool’s tract level rate of asthma related emergency department visits. PMID:25679341

  8. Luminescent screen composition and apparatus

    NASA Technical Reports Server (NTRS)

    Hilborn, E. H.

    1970-01-01

    Ultraviolet light projects photographically produced images on a screen composed of a mixture of linear and nonlinear phosphors whose spectral emissions are different. This allows the display of polychromatic luminescent images, which gives better discrimination of the objects being viewed.

  9. Nanoparticle-density-dependent field emission of surface-decorated SiC nanowires

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dong, Qizheng; School of Materials and Chemical Engineering, Ningbo University of Technology, Ningbo City 315016; State Key Lab of New Fine Ceramics and Fine Processing, Tsinghua University, Beijing City 100084

    2016-08-22

    Increasing the electron emission site density of nanostructured emitters with limited field screening effects is one of the key issues for improving the field emission (FE) properties. In this work, we reported the Au-nanoparticles-density-dependent field emission behaviors of surface-decorated SiC nanowires. The Au nanoparticles (AuNPs) decorated around the surface of the SiC nanowires were achieved via an ion sputtering technique, by which the densities of the isolated AuNPs could be adjusted by controlling the fixed sputtering times. The measured FE characteristics demonstrated that the turn-on fields of the SiC nanowires were tuned to be of 2.06, 1.14, and 3.35 V/μm withmore » the increase of the decorated AuNPs densities, suggesting that a suitable decorated AuNPs density could render the SiC nanowires with totally excellent FE performances by increasing the emission sites and limiting the field screening effects.« less

  10. The use of a microreactor for rapid screening of the reaction conditions and investigation of the photoluminescence mechanism of carbon dots.

    PubMed

    Lu, Yue; Zhang, Ling; Lin, Hengwei

    2014-04-07

    A microreactor is applied and reported, for the first time, in the field of research of carbon dots (CDs), including rapid screening of the reaction conditions and investigation of the photoluminescence (PL) mechanism. Various carbonaceous precursors and solvents were selected and hundreds of reaction conditions were screened (ca. 15 min on average per condition). Through analyzing the screened conditions, tunable PL emission maxima, from about 330 to 550 nm with respectable PL quantum yields, were achieved. Moreover, the relationship between different developmental stages of the CDs and the PL properties was explored by using the microreactor. The PL emission was observed to be independent of the composition, carbonization extent, and morphology/size of the CDs. This study unambiguously presents that a microreactor could serve as a promising tool for the research of CDs. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Hearing Screening Follow-Up: Completing the Process to Identify Hearing Health Needs

    ERIC Educational Resources Information Center

    Eiserman, William; Shisler, Lenore; Hoffman, Jeff

    2015-01-01

    Hearing is at the heart of language development and school readiness; increasing numbers of Early Head Start programs have come to rely on otoacoustic emissions (OAE) technology to screen all infants and toddlers for hearing loss. Successful identification of hearing health needs is dependent not only on an appropriate screening method, but also…

  12. Laser-emission imaging of nuclear biomarkers for high-contrast cancer screening and immunodiagnosis

    PubMed Central

    Chen, Yu-Cheng; Tan, Xiaotian; Sun, Qihan; Chen, Qiushu; Wang, Wenjie; Fan, Xudong

    2017-01-01

    Detection of nuclear biomarkers such as nucleic acids and nuclear proteins is critical for early-stage cancer diagnosis and prognosis. Conventional methods relying on morphological assessment of cell nuclei in histopathology slides may be subjective, whereas colorimetric immunohistochemical and fluorescence-based imaging are limited by strong light absorption, broad-emission bands and low contrast. Here, we describe the development and use of a scanning laser-emission-based microscope that maps lasing emissions from nuclear biomarkers in human tissues. 41 tissue samples from 35 patients labelled with site-specific and biomarker-specific antibody-conjugated dyes were sandwiched in a Fabry-Pérot microcavity while an excitation laser beam built a laser-emission image. We observed multiple sub-cellular lasing emissions from cancer cell nuclei, with a threshold of tens of μJ/mm2, sub-micron resolution (<700 nm), and a lasing band in the few-nanometre range. Different lasing thresholds of nuclei in cancer and normal tissues enabled the identification and multiplexed detection of nuclear proteomic biomarkers, with a high sensitivity for early-stage cancer diagnosis. Laser-emission-based cancer screening and immunodiagnosis might find use in precision medicine and facilitate research in cell biology. PMID:29204310

  13. Screening analysis and selection of emission reduction concepts for intermittent combustion aircraft engines

    NASA Technical Reports Server (NTRS)

    Rezy, B. J.; Meyers, J. E.; Tucker, J. R.; Stuckas, S. J.

    1976-01-01

    An analysis was conducted to screen, evaluate, and select three engine exhaust emission reduction concepts from a group of 14 candidate alternatives. A comprehensive literature search was conducted to survey the emission reduction technology state-of-the-art and establish contact with firms working on intermittent combustion engine development and pollution reduction problems. Concept development, advantages, disadvantages, and expected emission reduction responses are stated. A set of cost effectiveness criteria was developed, appraised for relative importance, and traded off against each concept so that its merit could be determined. A decision model was used to aid the evaluators in managing the criteria, making consistent judgements, calculating merit scores, and ranking the concepts. An Improved Fuel Injection System, Improved Cooling Combustion Chamber, and a Variable Timing Ignition System were recommended to NASA for approval and further concept development. An alternate concept, Air Injection, was also recommended.

  14. Readiness for Implementation of Lung Cancer Screening. A National Survey of Veterans Affairs Pulmonologists.

    PubMed

    Tukey, Melissa H; Clark, Jack A; Bolton, Rendelle; Kelley, Michael J; Slatore, Christopher G; Au, David H; Wiener, Renda Soylemez

    2016-10-01

    To mitigate the potential harms of screening, professional societies recommend that lung cancer screening be conducted in multidisciplinary programs with the capacity to provide comprehensive care, from screening through pulmonary nodule evaluation to treatment of screen-detected cancers. The degree to which this standard can be met at the national level is unknown. To assess the readiness of clinical facilities in a national healthcare system for implementation of comprehensive lung cancer screening programs, as compared with the ideal described in policy recommendations. This was a cross-sectional, self-administered survey of staff pulmonologists in pulmonary outpatient clinics in Veterans Health Administration facilities. The facility-level response rate was 84.1% (106 of 126 facilities with pulmonary clinics); 88.7% of facilities showed favorable provider perceptions of the evidence for lung cancer screening, and 73.6% of facilities had a favorable provider-perceived local context for screening implementation. All elements of the policy-recommended infrastructure for comprehensive screening programs were present in 36 of 106 facilities (34.0%); the most common deficiencies were the lack of on-site positron emission tomography scanners or radiation oncology services. Overall, 26.5% of Veterans Health Administration facilities were ideally prepared for lung cancer screening implementation (44.1% if the policy recommendations for on-site positron emission tomography scanners and radiation oncology services were waived). Many facilities may be less than ideally positioned for the implementation of comprehensive lung cancer screening programs. To ensure safe, effective screening, hospitals may need to invest resources or coordinate care with facilities that can offer comprehensive care for screening through downstream evaluation and treatment of screen-detected cancers.

  15. Investigation of soot and carbon formation in small gas turbine combustors

    NASA Technical Reports Server (NTRS)

    Rosfjord, T. J.

    1982-01-01

    An investigation of hardware configurations which attempt to minimize carbon and soot-production without sacrificing performance in small gas turbine combustors was conducted. Four fuel injectors, employing either airblast atomization, pressure atomization, or fuel vaporization techniques were combined with nozzle air swirlers and injector sheaths. Eight configurations were screened at sea-level takeoff and idle test conditions. Selected configurations were focused upon in an attempt to quantify the influence of combustor pressure, inlet temperature, primary zone operation, and combustor loading on soot and carbon formation. Cycle tests were also performed. It was found that smoke emission levels depended on the combustor fluid mechanics, the atomization quality of the injector and the fuel hydrogen content.

  16. Real-world volatile organic compound emission rates from seated adults and children for use in indoor air studies.

    PubMed

    Stönner, C; Edtbauer, A; Williams, J

    2018-01-01

    Human beings emit many volatile organic compounds (VOCs) of both endogenous (internally produced) and exogenous (external source) origin. Here we present real-world emission rates of volatile organic compounds from cinema audiences (50-230 people) as a function of time in multiple screenings of three films. The cinema location and film selection allowed high-frequency measurement of human-emitted VOCs within a room flushed at a known rate so that emissions rates could be calculated for both adults and children. Gas-phase emission rates are analyzed as a function of time of day, variability during the film, and age of viewer. The average emission rates of CO 2 , acetone, and isoprene were lower (by a factor of ~1.2-1.4) for children under twelve compared to adults while for acetaldehyde emission rates were equivalent. Molecules influenced by exogenous sources such as decamethylcyclopentasiloxanes and methanol tended to decrease over the course of day and then rise for late evening screenings. These results represent average emission rates of people under real-world conditions and can be used in indoor air quality assessments and building design. Averaging over a large number of people generates emission rates that are less susceptible to individual behaviors. © 2017 The Authors. Indoor Air published by John Wiley & Sons Ltd.

  17. Cervical cancer screening: A never-ending developing program

    PubMed Central

    Comparetto, Ciro; Borruto, Franco

    2015-01-01

    With the term “oncological screening”, we define the overall performances made to detect early onset of tumors. These tests are conducted on a population that does not have any signs or symptoms related to a neoplasm. The whole population above a certain age, only one sex, only subjects with a high risk of developing cancer due to genetic, professional, discretionary reasons may be involved. Screening campaigns should be associated, when risk factors that can be avoided are known, with campaigns for the prevention of cancer by means of suitable behavior. The goal of cancer screening cannot however be limited to the diagnosis of a greater number of neoplasms. Screening will be useful only if it leads to a reduction in overall mortality or at least in mortality related to the tumor. Screening should then allow the diagnosis of the disease at a stage when there is a possibility of healing, possibility that is instead difficult when the disease is diagnosed at the appearance of signs or symptoms. This is the reason why not all campaigns of cancer screening have the same effectiveness. In Italy, every year there are about 150000 deaths due to cancer. Some of these tumors can be cured with a very high percentage of success if diagnosed in time. Cervical cancer can be diagnosed with non-invasive tests. The screening test used all over the world is Papanicolaou (Pap) test. This test may be carried out over the entire healthy population potentially exposed to the risk of contracting cancer. Public health has begun the screening campaigns in the hope of saving many of the approximately 270000 new cases of cancer reported each year. Screening is done following protocols that guarantee quality at the national level: these protocols are subject to change over time to reflect new realities or to correct any errors in the system. A simplified sketch of a possible route of cancer screening is as follows: (1) after selecting the target population, for example all women between 25 and 64 years (in the case of monitoring of cervical cancer), an invitation letter with the date and time of the appointment, planned according to the acceptance capacity of the hospital, is sent to all individuals; (2) an examination, which depending on the individual and the type of cancer to be monitored, for example, can be a Pap smear, is performed and the patient can go home; (3) once available the results of examinations, if negative, they shall be communicated to the person concerned that will be notified by mail and will be recalled for a second test at a few years of distance, in the case of non-negativity, instead, the patient is contacted by telephone and informed of the need to carry out further examinations: it is said that the patient is in the “phase two” of the screening pathway; (4) in phase two, reached by only a small portion of the interested parties (usually less than 3%-5%), more in-depth tests are carried out, which, depending on the individual and the type of cancer, can be: cytological and colposcopic examinations, the removal of a fragment of tissue (biopsy) and subsequent histological examination, additional tests such as ultrasound, radiography, or others such as computerized tomography, magnetic resonance imaging, positron emission tomography, etc., in case of negativity, the concerned person will be called for new control tests at a a few years of distance, in case of non-negativity, it will be proposed instead an oncologic therapeutic plan and/or surgery to treat the diagnosed tumor; and (5) once the treatment plan is completed, the individual enters the follow-up protocol, which is monitored over time to see if the tumor has been completely removed or if instead it is still developing. Cervical cancer is undoubtedly the most successful example of a cancer screening campaign. Paradoxically, its effectiveness is one of the strongest reasons to criticize the usefulness of vaccination against human papillomavirus (HPV) in countries where the screening service with Pap test is organized in an efficient manner. Cervical cancer screening protocols are directed to sexually active women aged 25-64 years: they provide the Pap test performed by examining under a microscope or by staining with a specific “thin prep” the material taken from the cervix with a small spatula and a brush. It is recommended to repeat the test every two or three years. It is important to emphasize that women vaccinated against HPV must continue the screening with Pap test. Although some screening programs (e.g., Pap smears) have had remarkable success in reducing mortality from a specific cancer, any kind of screening is free from inherent limitations. The screening methods are in fact applied to large parts of the apparently healthy population. In particular, the limits for certain cancers may be as obvious as to prohibit the introduction of an organized screening program. Potential limitations of organized screenings are basically of two types: organizational and medical. The limits of organizational type relate to the ability of a program to recruit the whole target population. Although well organized, a screening program will hardly be able to exceed a coverage of 70%-80% of the target population, and in fact the results of the current programs are often much smaller. The limits of medical type are represented by the possibility of reducing the overall mortality, or specific mortality, using a specific screening campaign. PMID:26244153

  18. Fumigation of Alcohol in a Light Duty Automotive Diesel Engine

    NASA Technical Reports Server (NTRS)

    Broukhiyan, E. M. H.; Lestz, S. S.

    1981-01-01

    A light-duty automotive Diesel engine was fumigated with methanol in amounts up to 35% and 50% of the total fuel energy respectively in order to determine the effect of alcohol fumigation on engine performance at various operating conditons. Engine fuel efficiency, emissions, smoke, and the occurrence of severe knock were the parameters used to evaluate performance. Raw exhaust particulate and its soluble organic extract were screened for biological activity using the Ames Salmonella typhimurium assay. Results are given for a test matrix made up of twelve steady-state operating conditions. For all conditions except the 1/4 rack (light load) condition, modest thermal efficiency gains were noted upon ethanol fumigation. Methanol showed the same increase at 3/4 and full rack (high load) conditions. However, engine roughness or the occurrence of severe knock limited the maximum amount of alcohol that could be fumigated. Brake specific nitrogen oxide concentrations were found to decrease for all ethanol conditions tested. Oxides of nitrogen emissions, on a volume basis, decreased for all alcohol conditions tested. Based on the limited particulate data analyzed, it appears that ethanol fumigation, like methanol fumigation, while lowering the mass of particulated emitted, does enhance the biological activity of that particulate.

  19. Systematic Review of Life Cycle Greenhouse Gas Emissions from Geothermal Electricity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eberle, Annika; Heath, Garvin A.; Carpenter Petri, Alberta C.

    The primary goal of this work was to assess the magnitude and variability of published life cycle greenhouse gas (GHG) emission estimates for three types of geothermal electricity generation technologies: enhanced geothermal systems (EGS) binary, hydrothermal (HT) flash, and HT binary. These technologies were chosen to align the results of this report with technologies modeled in National Renewable Energy Laboratory's (NREL's) Regional Energy Deployment Systems (ReEDs) model. Although we did gather and screen life cycle assessment (LCA) literature on hybrid systems, dry steam, and two geothermal heating technologies, we did not analyze published GHG emission estimates for these technologies. Inmore » our systematic literature review of the LCA literature, we screened studies in two stages based on a variety of criteria adapted from NREL's Life Cycle Assessment (LCA) Harmonization study (Heath and Mann 2012). Of the more than 180 geothermal studies identified, only 29 successfully passed both screening stages and only 26 of these included estimates of life cycle GHG emissions. We found that the median estimate of life cycle GHG emissions (in grams of carbon dioxide equivalent per kilowatt-hour generated [g CO2eq/kWh]) reported by these studies are 32.0, 47.0, and 11.3 for EGS binary, HT flash, and HT binary, respectively (Figure ES-1). We also found that the total life cycle GHG emissions are dominated by different stages of the life cycle for different technologies. For example, the GHG emissions from HT flash plants are dominated by the operations phase owing to the flash cycle being open loop whereby carbon dioxide entrained in the geothermal fluids is released to the atmosphere. This is in contrast to binary plants (using either EGS or HT resources), whose GHG emissions predominantly originate in the construction phase, owing to its closed-loop process design. Finally, by comparing this review's literature-derived range of HT flash GHG emissions to data from currently operating geothermal plants, we found that emissions from operational plants exhibit more variability and the median of emissions from operational plants is twice the median of operational emissions reported by LCAs. Further investigation is warranted to better understand the cause of differences between published LCAs and estimates from operational plants and to develop LCA analytical approaches that can yield estimates closer to actual emissions.« less

  20. Carbon nanotube emitters and field emission triode

    NASA Astrophysics Data System (ADS)

    Fan, Zhiqin; Zhang, Binglin; Yao, Ning; Zhang, Lan; Ma, Huizhong; Deng, Jicai

    2006-05-01

    Based on our study on field emission from multi-walled carbon nanotubes (MWNTs), we experimentally manufactured field emission display (FED) triode with a MWNTs cold cathode, and demonstrated an excellent performance of MWNTs as field emitters. The measured luminance of the phosphor screens was 1.8*10^(3) cd/m2 for green light. The emission is stable with a fluctuation of only 1.5% at an average current of 260 'mu'A.

  1. Comparison of a new digital KM screen test with conventional Hess and Lees screen tests in the mapping of ocular deviations.

    PubMed

    Thorisdottir, Rannveig Linda; Sundgren, Johanna; Sheikh, Rafi; Blohmé, Jonas; Hammar, Björn; Kjellström, Sten; Malmsjö, Malin

    2018-05-28

    To evaluate the digital KM screen computerized ocular motility test and to compare it with conventional nondigital techniques using the Hess and Lees screens. Patients with known ocular deviations and a visual acuity of at least 20/100 underwent testing using the digital KM screen and the Hess and Lees screen tests. The examination duration, the subjectively perceived difficulty, and the patient's method of choice were compared for the three tests. The accuracy of test results was compared using Bland-Altman plots between testing methods. A total of 19 patients were included. Examination with the digital KM screen test was less time-consuming than tests with the Hess and Lees screens (P < 0.001 and P = 0.003, resp., compared with the digital KM screen). Patients found the test with the digital KM screen easier to perform than the Lees screen test (P = 0.009) but of similar difficulty to the Hess screen test (P = 0.203). The majority of the patients (83%) preferred the digital KM screen test to both of the other screen methods (P = 0.008). Bland-Altman plots showed that the results obtained with all three tests were similar. The digital KM screen is accurate and time saving and provides similar results to Lees and Hess screen testing. It also has the advantage of a digital data analysis and registration. Copyright © 2018 American Association for Pediatric Ophthalmology and Strabismus. Published by Elsevier Inc. All rights reserved.

  2. Performance of two hearing screening protocols in NICU in Shanghai.

    PubMed

    Xu, Zheng-Min; Cheng, Wen-Xia; Yang, Xiao-Lin

    2011-10-01

    To study the sensitivity and specificity of targeted neonatal hearing screening for the single-session distortion product otoacoustic emissions (DPOAE) technique and the combined DPOAE/automated auditory brain-stem response (AABR) technique. 3000 high-risk newborns were studied at Children's Hospital of Fudan University. They were required to take two different screening procedures separately. The first procedure consisted of DPOAE alone and the second consisted of DPOAE combined with the AABR. Based upon the etiology in high-risk babies, they were divided into four groups. In group I there were 670 very-low-birth-weight (VLBW) newborns (1340 ears), and in group II there were 890 preterm babies (1780 ears). 850 babies (1700 ears) suffered from hyperbilirubinemia in group III, whereas 790 babies (1580 ears) with asphyxia were in group IV. The babies in groups II, III, and IV came from the neonatal intensive-care unit (NICU) of our hospital. The study protocols consisted of the DPOAE alone and DPOAE combined with AABR hearing screening at an age of less than 1 month, and a diagnostic stage at the age of 2 months. With single-session DPOAE screening, the referral rate (8% of the NICU babies), the false-positive rate (4.96%) and the false-negative rate (0.8%) were higher. The different etiologies in NICU babies had significantly different referral rates (F-test, p<0.01). A 4.46% referral rate of hyperbilirubinemi babies was much lower. The combined DPOAE/AABR screening technique revealed a referral rate of 5.03%, a false-positive rate of 2% and a false-negative rate of 0.06%. The false-positive rate was well below the suggested 3% of the American Academy of Pediatric. Comparisons of the referral rate, false-positive rate and false-negative rate of two hearing screening protocols (DPOAE alone and combined DPOAE/AABR) revealed significant differences (t-test, p<0.05, p<0.01, p<0.01). 91 infants (3.03% of the NICU babies) who failed the combined DPOAE/AABR screening were confirmed on hearing impairment. Of 22 babies who passed DPOAE screening but failed the AABR screening had a severe to profound hearing loss based on classic ABR. These patients (24% of the NICU babies with hearing losses) with hyperbilirubinemia and asphyxia problems at newborn stage were diagnosed as auditory neuropathy based on evaluations of DPOAE screening passed, abnormal ABR and absent middle-ear muscle reflexes (MMR). Our study demonstrates the use of a combination of DPOAE and AABR testing ensures high sensitivity and acceptable specificity, and predict the AN profile in NICU babies. Our efforts identified 22 NICU babies with auditory neuropathy who hopefully will benefit from early remediation of their hearing deficit. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  3. Field emission characteristics of a small number of carbon fiber emitters

    NASA Astrophysics Data System (ADS)

    Tang, Wilkin W.; Shiffler, Donald A.; Harris, John R.; Jensen, Kevin L.; Golby, Ken; LaCour, Matthew; Knowles, Tim

    2016-09-01

    This paper reports an experiment that studies the emission characteristics of small number of field emitters. The experiment consists of nine carbon fibers in a square configuration. Experimental results show that the emission characteristics depend strongly on the separation between each emitter, providing evidence of the electric field screening effects. Our results indicate that as the separation between the emitters decreases, the emission current for a given voltage also decreases. The authors compare the experimental results to four carbon fiber emitters in a linear and square configurations as well as to two carbon fiber emitters in a paired array. Voltage-current traces show that the turn-on voltage is always larger for the nine carbon fiber emitters as compared to the two and four emitters in linear configurations, and approximately identical to the four emitters in a square configuration. The observations and analysis reported here, based on Fowler-Nordheim field emission theory, suggest the electric field screening effect depends critically on the number of emitters, the separation between them, and their overall geometric configuration.

  4. A comparison of a mini-PEMS and a 1065 compliant PEMS for on-road gaseous and particulate emissions from a light duty diesel truck.

    PubMed

    Yang, Jiacheng; Durbin, Thomas D; Jiang, Yu; Tange, Takeshi; Karavalakis, Georgios; Cocker, David R; Johnson, Kent C

    2018-05-31

    The primary goal of this study was to compare emissions measurements between a 1065 compliant PEMS, and the NTK Compact Emissions Meter (NCEM) capable of measuring NOx, PM, and solid PN. Both units were equipped on a light-duty diesel truck and tested over local, highway, and downtown driving routes. The results indicate that the NOx measurements for the NCEM were within approximately ±10% of those the 1065 compliant PEMS, which suggests that the NCEM could be used as a screening tool for NOx emissions. The NCEM showed larger differences for PM emissions on an absolute level, but this was at PM levels well below the 1 mg/mi level. The NCEM differences ranged from -2% to +26% if the comparisons are based on a percentage of the 1.0 mg/mi standard. Larger differences were also seen for PN emissions, with the NCEM measuring higher PN emissions, which can primarily be attributed to a zero current offset that we observed for the NCEM, which has been subsequently improved in the latest generation of the NCEM system. The comparisons between the 1065 compliant PEMS and the NCEM suggest that there could be applications for the NCEM or other mini-PEMS for applications such as identification of potential issues by regulatory agencies, manufacturer evaluation and validation of emissions under in-use conditions, and potential use in inspection and maintenance (I/M) programs, especially for heavy-duty vehicles. Copyright © 2017. Published by Elsevier B.V.

  5. Colon cancer screening

    MedlinePlus

    Screening for colon cancer; Colonoscopy - screening; Sigmoidoscopy - screening; Virtual colonoscopy - screening; Fecal immunochemical test; Stool DNA test; sDNA test; Colorectal cancer - screening; Rectal ...

  6. Electroantennographic Bioassay as a Screening Tool for Host Plant Volatiles

    PubMed Central

    Beck, John J.; Light, Douglas M.; Gee, Wai S.

    2012-01-01

    Plant volatiles play an important role in plant-insect interactions. Herbivorous insects use plant volatiles, known as kairomones, to locate their host plant.1,2 When a host plant is an important agronomic commodity feeding damage by insect pests can inflict serious economic losses to growers. Accordingly, kairomones can be used as attractants to lure or confuse these insects and, thus, offer an environmentally friendly alternative to pesticides for insect control.3 Unfortunately, plants can emit a vast number volatiles with varying compositions and ratios of emissions dependent upon the phenology of the commodity or the time of day. This makes identification of biologically active components or blends of volatile components an arduous process. To help identify the bioactive components of host plant volatile emissions we employ the laboratory-based screening bioassay electroantennography (EAG). EAG is an effective tool to evaluate and record electrophysiologically the olfactory responses of an insect via their antennal receptors. The EAG screening process can help reduce the number of volatiles tested to identify promising bioactive components. However, EAG bioassays only provide information about activation of receptors. It does not provide information about the type of insect behavior the compound elicits; which could be as an attractant, repellent or other type of behavioral response. Volatiles eliciting a significant response by EAG, relative to an appropriate positive control, are typically taken on to further testing of behavioral responses of the insect pest. The experimental design presented will detail the methodology employed to screen almond-based host plant volatiles4,5 by measurement of the electrophysiological antennal responses of an adult insect pest navel orangeworm (Amyelois transitella) to single components and simple blends of components via EAG bioassay. The method utilizes two excised antennae placed across a "fork" electrode holder. The protocol demonstrated here presents a rapid, high-throughput standardized method for screening volatiles. Each volatile is at a set, constant amount as to standardize the stimulus level and thus allow antennal responses to be indicative of the relative chemoreceptivity. The negative control helps eliminate the electrophysiological response to both residual solvent and mechanical force of the puff. The positive control (in this instance acetophenone) is a single compound that has elicited a consistent response from male and female navel orangeworm (NOW) moth. An additional semiochemical standard that provides consistent response and is used for bioassay studies with the male NOW moth is (Z,Z)-11,13-hexdecadienal, an aldehyde component from the female-produced sex pheromone.6-8 PMID:22588282

  7. Otoacoustic Emissions in Rural Nicaragua: Cost Analysis and Implications for Newborn Hearing Screening.

    PubMed

    Wong, Lye-Yeng; Espinoza, Francisca; Alvarez, Karen Mojica; Molter, Dave; Saunders, James E

    2017-05-01

    Objective (1) Determine the incidence and risk factors for congenital hearing loss. (2) Perform cost analysis of screening programs. Study Design Proportionally distributed cross-sectional survey. Setting Jinotega, Nicaragua. Subjects and Methods Otoacoustic emissions (OAEs) were used to screen 640 infants <6 months of age from neonatal intensive care unit, institutional, and home birth settings. Data on 15 risk factors were analyzed. Cost of 4 implementation strategies was studied: universal screening, screening at the regional health center (RHC), targeted screening, and screening at the RHC plus targeted screening. Cost-effectiveness analysis over 10 years was based on disability-adjusted life year estimates, with the World Health Organization standard of cost-effectiveness ratio (CER) / gross domestic product (GDP) <3, with GDP set at $4884.15. Results Thirty-eight infants failed the initial OAE (5.94%). In terms of births, 325 (50.8%) were in the RHC, 69 (10.8%) in the neonatal intensive care unit, and 29 (4.5%) at home. Family history and birth defect were significant in univariate analysis; birth defect was significant in multivariate analysis. Cost-effectiveness analysis demonstrated that OAE screening is cost-effective without treatment (CER/GDP = 0.06-2.00) and with treatment (CER/GDP = 0.58-2.52). Conclusions Our rate of OAE failures was comparable to those of developed countries and lower than hearing loss rates noted among Nicaraguan schoolchildren, suggesting acquired or progressive etiology in the latter. Birth defects and familial hearing loss correlated with OAE failure. OAE screening of infants is feasible and cost-effective in rural Nicaragua, although highly influenced by estimated hearing loss severity in identified infants and the high travel costs incurred in a targeted screening strategy.

  8. Assimilation of Feng-Yun-3B satellite microwave humidity sounder data over land

    NASA Astrophysics Data System (ADS)

    Chen, Keyi; Bormann, Niels; English, Stephen; Zhu, Jiang

    2018-03-01

    The ECMWF has been assimilating Feng-Yun-3B (FY-3B) satellite microwave humidity sounder (MWHS) data over ocean in an operational forecasting system since 24 September 2014. It is more difficult, however, to assimilate microwave observations over land and sea ice than over the open ocean due to higher uncertainties in land surface temperature, surface emissivity and less effective cloud screening. We compare approaches in which the emissivity is retrieved dynamically from MWHS channel 1 [150 GHz (vertical polarization)] with the use of an evolving emissivity atlas from 89 GHz observations from the MWHS onboard NOAA and EUMETSAT satellites. The assimilation of the additional data over land improves the fit of short-range forecasts to other observations, notably ATMS (Advanced Technology Microwave Sounder) humidity channels, and the forecast impacts are mainly neutral to slightly positive over the first five days. The forecast impacts are better in boreal summer and the Southern Hemisphere. These results suggest that the techniques tested allow for effective assimilation of MWHS/FY-3B data over land.

  9. Sensing Properties of Multiwalled Carbon Nanotubes Grown in MW Plasma Torch: Electronic and Electrochemical Behavior, Gas Sensing, Field Emission, IR Absorption

    PubMed Central

    Majzlíková, Petra; Sedláček, Jiří; Prášek, Jan; Pekárek, Jan; Svatoš, Vojtěch; Bannov, Alexander G.; Jašek, Ondřej; Synek, Petr; Eliáš, Marek; Zajíčková, Lenka; Hubálek, Jaromír

    2015-01-01

    Vertically aligned multi-walled carbon nanotubes (VA-MWCNTs) with an average diameter below 80 nm and a thickness of the uniform VA-MWCNT layer of about 16 μm were grown in microwave plasma torch and tested for selected functional properties. IR absorption important for a construction of bolometers was studied by Fourier transform infrared spectroscopy. Basic electrochemical characterization was performed by cyclic voltammetry. Comparing the obtained results with the standard or MWCNT‐modified screen-printed electrodes, the prepared VA-MWCNT electrodes indicated their high potential for the construction of electrochemical sensors. Resistive CNT gas sensor revealed a good sensitivity to ammonia taking into account room temperature operation. Field emission detected from CNTs was suitable for the pressure sensing application based on the measurement of emission current in the diode structure with bending diaphragm. The advantages of microwave plasma torch growth of CNTs, i.e., fast processing and versatility of the process, can be therefore fully exploited for the integration of surface-bound grown CNTs into various sensing structures. PMID:25629702

  10. An analysis of the costs of implementing the National Newborn Hearing Screening Programme in England.

    PubMed

    Uus, K; Bamford, J; Taylor, R

    2006-01-01

    The primary aim of this analysis was to prospectively assess the full economic costs associated with implementing Newborn Hearing Screening Programme (NHSP) based on a two-stage screen, transient evoked otoacoustic emissions followed, if there is no clear response, by automated auditory brainstem response. Economic data were also collected from the Infant Distraction Test Screening (IDTS) service performed by health visitors at around eight months of age, which was being phased out. A comparison of costs and outcomes associated with NHSP and IDTS was conducted. 20 NHSP sites were invited to provide detailed cost data on NHSP implementation and 14 of these sites were selected to provide costs on the IDTS service that was being supplanted. There was marked variability in the costs. Given the higher yield of NHSP sites, the average cost per case detected across NHSP sites (31,410 pounds/case) was approximately half that of IDTS sites (69,919 pounds/case). Including family costs, the average total cost per case of NHSP (34,826 pounds/case) was almost a quarter of IDTS (117,942 pounds/case). Family costs and cost per case associated with NHSP are considerably less than that with IDTS. These findings support the policy of implementation of NHSP and the phasing out of the IDTS.

  11. From Roentgen to magnetic resonance imaging: the history of medical imaging.

    PubMed

    Scatliff, James H; Morris, Peter J

    2014-01-01

    Medical imaging has advanced in remarkable ways since the discovery of x-rays 120 years ago. Today's radiologists can image the human body in intricate detail using computed tomography, magnetic resonance imaging, positron emission tomography, ultrasound, and various other modalities. Such technology allows for improved screening, diagnosis, and monitoring of disease, but it also comes with risks. Many imaging modalities expose patients to ionizing radiation, which potentially increases their risk of developing cancer in the future, and imaging may also be associated with possible allergic reactions or risks related to the use of intravenous contrast agents. In addition, the financial costs of imaging are taxing our health care system, and incidental findings can trigger anxiety and further testing. This issue of the NCMJ addresses the pros and cons of medical imaging and discusses in detail the following uses of medical imaging: screening for breast cancer with mammography, screening for osteoporosis and monitoring of bone mineral density with dual-energy x-ray absorptiometry, screening for congenital hip dysplasia in infants with ultrasound, and evaluation of various heart conditions with cardiac imaging. Together, these articles show the challenges that must be met as we seek to harness the power of today's imaging technologies, as well as the potential benefits that can be achieved when these hurdles are overcome.

  12. Analysis of otoacoustic emissions in neonates at term and preterm.

    PubMed

    Cavalcante, Juliana Maria Soares; Isaac, Myriam de Lima

    2013-01-01

    The transient evoked otoacoustic emissions (TEOAEs) have been widely used in neonatal hearing screening. To compare the TEOAEs in newborns at term and preterm vis-à-vis the following variables: ear side, gender, frequency spectrum and gestational age. By means of a cross-sectional cohort of 66 newborns up to the 28th day of life (41 newborns at term and 25 premature babies), we recorded TEOAEs. All the individuals did not have risk indicators for hearing loss. There was a signal/noise ratio improvement with frequency increase. No differences were observed between genders and between the ears, but there were differences among the children born at term and preterm in the frequency bands at 3 kHz and 4 kHz. The TEOAEs test is important for assessing the peripheral auditory system of newborns at term and preterm, making it possible to have responses regardless of gender and gestational age.

  13. Validation of a noninvasive test routinely used in otology for the diagnosis of cerebrospinal fluid shunt malfunction in patients with normal pressure hydrocephalus.

    PubMed

    Sakka, Laurent; Chomicki, Alexandre; Gabrillargues, Jean; Khalil, Toufic; Chazal, Jean; Avan, Paul

    2016-02-01

    Ventriculoperitoneal shunting is the first-line treatment for normal pressure hydrocephalus. Noninvasive auditory tests based on recorded otoacoustic emissions were assessed, as currently used for universal neonatal hearing screenings, for the diagnosis of cerebrospinal fluid shunt malfunction. The test was designed based on previous works, which demonstrated that an intracranial pressure change induces a proportional, characteristic, otoacoustic-emission phase shift. Forty-four patients with normal pressure hydrocephalus (23 idiopathic and 21 secondary cases) were included in this prospective observational study. The male:female sex ratio was 1.44, the age range was 21-87 years (mean age 64.3 years), and the range of the follow-up period was 1-3 years (mean 20 months). Patients were implanted with a Sophy SU8 adjustable-pressure valve as the ventriculoperitoneal shunt. The phase shifts of otoacoustic emissions in response to body tilt were measured preoperatively, immediately postoperatively, and at 3-6 months, 7-15 months, 16-24 months, and more than 24 months postoperatively. Three groups were enrolled: Group 1, 19 patients who required no valve opening-pressure adjustment; Group 2, 18 patients who required valve opening-pressure adjustments; and Group 3, 7 patients who required valve replacement. In Group 1, phase shift, which was positive before surgery, became steadily negative after surgery and during the follow-up. In Group 2, phase shift, which was positive before surgery, became negative immediately after surgery and increasingly negative after a decrease in the valve-opening pressure. In Group 3, phase shift was positive in 6 cases and slightly negative in 1 case before revision, but after revision phase shift became significantly negative in all cases. Otoacoustic emissions noninvasively reflect cerebrospinal fluid shunt function and are impacted by valve-opening pressure adjustments. Otoacoustic emissions consistently diagnosed shunt malfunction and predicted the need for surgical revision. The authors' diagnostic test, which can be repeated without risk or discomfort by an unskilled operator, may address the crucial need of detecting valve dysfunction in patients with poor clinical outcome after shunt surgery.

  14. Measurement of the secondary electron emission from CVD diamond films using phosphor screen detectors

    NASA Astrophysics Data System (ADS)

    Vaz, R.; May, P. W.; Fox, N. A.; Harwood, C. J.; Chatterjee, V.; Smith, J. A.; Horsfield, C. J.; Lapington, J. S.; Osbourne, S.

    2015-03-01

    Diamond-based photomultipliers have the potential to provide a significant improvement over existing devices due to diamond's high secondary electron yield and narrow energy distribution of secondary electrons which improves energy resolution creating extremely fast response times. In this paper we describe an experimental apparatus designed to study secondary electron emission from diamond membranes only 400 nm thick, observed in reflection and transmission configurations. The setup consists of a system of calibrated P22 green phosphor screens acting as radiation converters which are used in combination with photomultiplier tubes to acquire secondary emission yield data from the diamond samples. The superior signal voltage sampling of the phosphor screen setup compared with traditional Faraday Cup detection allows the variation in the secondary electron yield across the sample to be visualised, allowing spatial distributions to be obtained. Preliminary reflection and transmission yield data are presented as a function of primary electron energy for selected CVD diamond films and membranes. Reflection data were also obtained from the same sample set using a Faraday Cup detector setup. In general, the curves for secondary electron yield versus primary energy for both measurement setups were comparable. On average a 15-20% lower signal was recorded on our setup compared to the Faraday Cup, which was attributed to the lower photoluminescent efficiency of the P22 phosphor screens when operated at sub-kilovolt bias voltages.

  15. The photo-oxidation of automobile emissions: measurements of the transformation products and their mutagenic activity

    NASA Astrophysics Data System (ADS)

    Kleindienst, Tadeusz E.; Smith, David F.; Hudgens, Edward E.; Snow, Richard F.; Perry, Erica; Claxton, Larry D.; Bufalini, Joseph J.; Black, Francis M.; Cupitt, Larry T.

    Dilute mixtures of automobile emissions (comprising 50% exhaust and 50% surrogate evaporative emissions) were irradiated in a 22.7 m 3 smog chamber and tested for mutagenic activity by using a variant of the Ames test. The exhaust was taken from a single vehicle, a 1977 Ford Mustang equipped with a catalytic converter. Irradiated and nonirradiated gas-phase emissions were used in exposures of the bacteria, Salmonella typhimurium, strains TA100 and TA98. A single set of vehicular operating conditions was used to perform multiple exposures. The mutagenic activities of extracts from the particulate phase were also measured with the standard plate incorporation assay. (In most experiments only direct-acting mutagenic compounds were measured.) The gas-phase data for TA100 and TA98 showed increased activity for the irradiated emissions when compared to the nonirradiated mixture, which exhibited negligible activity with respect to the control values. The particulate phase for both the irradiated and nonirradiated mixtures showed negligible activity when results were compared to the control values for both strains. However, the experimental conditions limited the amount of extractable mass which could be collected in the particulate phase. The measured activities from the gas phase and particulate phase were converted to the number of revertants per cubic meter of effluent (i.e. the mutagenic density) to compare the contributions of each of these phases to the total mutagenic activity for each strain. Under the experimental conditions of this study, the mutagenic density of the gas-phase component of the irradiated mixture contributed approximately two orders of magnitude more of the total TA100 activity than did the particulate phase. For TA98 the gas-phase component contributed approximately one order of magnitude more. However, caution must be exercised in extrapolating these results to urban atmospheres heavily impacted by automotive emissions, because the bacterial mutagenicity assay was used as a screening method, and additional assays using mammalian systems have not yet been conducted. In addition, only limited number of conditions were able to be tested. The significance and limitations of the results are discussed.

  16. Arrays of Bundles of Carbon Nanotubes as Field Emitters

    NASA Technical Reports Server (NTRS)

    Manohara, Harish; Bronkowski, Michael

    2007-01-01

    Experiments have shown that with suitable choices of critical dimensions, planar arrays of bundles of carbon nanotubes (see figure) can serve as high-current-density field emitter (cold-cathode) electron sources. Whereas some hot-cathode electron sources must be operated at supply potentials of thousands of volts, these cold-cathode sources generate comparable current densities when operated at tens of volts. Consequently, arrays of bundles of carbon nanotubes might prove useful as cold-cathode sources in miniature, lightweight electron-beam devices (e.g., nanoklystrons) soon to be developed. Prior to the experiments, all reported efforts to develop carbon-nanotube-based field-emission sources had yielded low current densities from a few hundred microamperes to a few hundred milliamperes per square centimeter. An electrostatic screening effect, in which taller nanotubes screen the shorter ones from participating in field emission, was conjectured to be what restricts the emission of electrons to such low levels. It was further conjectured that the screening effect could be reduced and thus emission levels increased by increasing the spacing between nanotubes to at least by a factor of one to two times the height of the nanotubes. While this change might increase the emission from individual nanotubes, it would decrease the number of nanotubes per unit area and thereby reduce the total possible emission current. Therefore, to maximize the area-averaged current density, it would be necessary to find an optimum combination of nanotube spacing and nanotube height. The present concept of using an array of bundles of nanotubes arises partly from the concept of optimizing the spacing and height of field emitters. It also arises partly from the idea that single nanotubes may have short lifetimes as field emitters, whereas bundles of nanotubes could afford redundancy so that the loss of a single nanotube would not significantly reduce the overall field emission.

  17. Deriving fuel-based emission factor thresholds to interpret heavy-duty vehicle roadside plume measurements.

    PubMed

    Quiros, David C; Smith, Jeremy D; Ham, Walter A; Robertson, William H; Huai, Tao; Ayala, Alberto; Hu, Shaohua

    2018-04-13

    Remote sensing devices have been used for decades to measure gaseous emissions from individual vehicles at the roadside. Systems have also been developed that entrain diluted exhaust and can also measure particulate matter (PM) emissions. In 2015, the California Air Resources Board (CARB) reported that 8% of in-field diesel particulate filters (DPF) on heavy-duty (HD) vehicles were malfunctioning and emitted about 70% of total diesel PM emissions from the DPF-equipped fleet. A new high-emitter problem in the heavy-duty vehicle fleet had emerged. Roadside exhaust plume measurements reflect a snapshot of real-world operation, typically lasting several seconds. In order to relate roadside plume measurements to laboratory emission tests, we analyzed carbon dioxide (CO 2 ), oxides of nitrogen (NO X ), and PM emissions collected from four HD vehicles during several driving cycles on a chassis dynamometer. We examined the fuel-based emission factors corresponding to possible exceedances of emission standards as a function of vehicle power. Our analysis suggests that a typical HD vehicle will exceed the model year (MY) 2010 emission standards (of 0.2 g NO X /bhp-hr and 0.01 g PM/bhp-hr) by three times when fuel-based emission factors are 9.3 g NO X /kg fuel and 0.11 g PM/kg using the roadside plume measurement approach. Reported limits correspond to 99% confidence levels, which were calculated using the detection uncertainty of emissions analyzers, accuracy of vehicle power calculations, and actual emissions variability of fixed operational parameters. The PM threshold was determined for acceleration events between 0.47 and 1.4 mph/sec only, and the NO X threshold was derived from measurements where aftertreatment temperature was above 200°C. Anticipating a growing interest in real-world driving emissions, widespread implementation of roadside exhaust plume measurements as a compliment to in-use vehicle programs may benefit from expanding this analysis to a larger sample of in-use HD vehicles. Implications Regulatory agencies, civil society, and the public at large have a growing interest in vehicle emission compliance in the real world. Leveraging roadside plume measurements to identify vehicles with malfunctioning emission control systems is emerging as a viable new and useful method to assess in-use performance. This work proposes fuel-based emission factor thresholds for PM and NOx that signify exceedances of emission standards on a work-specific basis by analyzing real-time emissions in the laboratory. These thresholds could be used to pre-screen vehicles before roadside enforcement inspection or other inquiry, enhance and further develop emission inventories, and potentially develop new requirements for heavy-duty inspection and maintenance (I/M) programs, including but not limited to identifying vehicles for further testing.

  18. DEVELOPMENT OF THE METAL FINISHING FACILITY RISK SCREENING TOOL (MFFRST)

    EPA Science Inventory

    Recently the US EPA completed the development of the first version of the Metal Finishing Facility Risk Screening Tool (MFFRST) and has made this product available to the general public. MFFRST calculates the air emissions from a metal plating line and determines the risk to bot...

  19. Solar UV irradiation-induced production of N2O from plant surfaces - low emissions rates but all over the world.

    NASA Astrophysics Data System (ADS)

    Mikkelsen, T. N.; Bruhn, D.; Ambus, P.

    2016-12-01

    Nitrous oxide (N2O) is an important long-lived greenhouse gas and precursor of stratospheric ozone depleting mono-nitrogen oxides. The atmospheric concentration of N2O is persistently increasing; however, large uncertainties are associated with the distinct source strengths. Here we investigate for the first time N2O emission from terrestrial vegetation in response to natural solar ultra violet radiation. We conducted field site measurements to investigate N2O atmosphere exchange from grass vegetation exposed to solar irradiance with and without UV-screening. Further laboratory tests were conducted with a range of species to study the controls and possible loci of UV-induced N2O emission from plants. Plants released N2O in response to natural sunlight at rates of c. 20-50 nmol m-2 h-1, mostly due to the UV component. The emission rate is temperature dependent with a rather high activation energy indicative for an abiotic process. The prevailing zone for the N2O formation appears to be at the very surface of leaves. However, only c. 26% of the UV-induced N2O appears to originate from plant-N. Further, the process is dependent on atmospheric oxygen concentration. Our work demonstrates that ecosystem emission of the important greenhouse gas, N2O, may be up to c. 30% higher than hitherto assumed.

  20. Assessment of risks of EMI for personal medical electronic devices (PMEDs) from emissions of millimeter-wave security screening systems

    NASA Astrophysics Data System (ADS)

    Witters, Donald; Bassen, Howard; Guag, Joshua; Addissie, Bisrat; LaSorte, Nickolas; Rafai, Hazem

    2013-06-01

    This paper describes research and testing of a representative group of high priority body worn and implantable personal medical electronic devices (PMEDs) for exposure to millimeter wave (MMW) advanced imaging technology (AIT) security systems used at airports. The sample PMEDs included in this study were implantable cardiac pacemakers, ICDs, neurostimulators and insulin pumps. These PMEDs are designed and tested for susceptibility to electromagnetic interference (EMI) under the present standards for medical device electromagnetic compatibility (EMC). However, the present standards for medical equipment do not address exposure to the much higher frequency fields that are emitted by MMW security systems. Initial AIT emissions measurements were performed to assess the PMED and passenger exposures. Testing protocols were developed and testing methods were tailored to the type of PMED. In addition, a novel exposure simulation system was developed to allow controlled EMC testing without the need of the MMW AIT system. Methodology, test results, and analysis are presented, along with an assessment of the human exposure and risks for PMED users. The results on this study reveal no effects on the medical devices from the exposure to the MMW security system. Furthermore, the human exposure measurements and analysis showed levels well below applicable standard, and the risks for PMED users and others we assessed to be very low. These findings apply to the types of PMEDs used in the study though these findings might suggest that the risks for other, similar PMEDs would likely be similar.

  1. Automobile gross emitter screening with remote sensing data using objective-oriented neural network.

    PubMed

    Chen, Ho-Wen; Yang, Hsi-Hsien; Wang, Yu-Sheng

    2009-11-01

    One of the costs of Taiwan's massive economic development has been severe air pollution problems in many parts of the island. Since vehicle emissions are the major source of air pollution in most of Taiwan's urban areas, Taiwan's government has implemented policies to rectify the degrading air quality, especially in areas with high population density. To reduce vehicle pollution emissions an on-road remote sensing and monitoring system is used to check the exhaust emissions from gasoline engine automobiles. By identifying individual vehicles with excessive emissions for follow-up inspection and testing, air quality in the urban environment is expected to improve greatly. Because remote sensing is capable of measuring a large number of moving vehicles in a short period, it has been considered as an assessment technique in place of the stationary emission-sampling techniques. However, inherent measurement uncertainty of remote sensing instrumentation, compounded by the indeterminacy of monitoring site selection, plus the vagaries of weather, causes large errors in pollution discrimination and limits the application of the remote sensing. Many governments are still waiting for a novel data analysis methodology to clamp down on heavily emitting vehicles by using remote sensing data. This paper proposes an artificial neural network (ANN), with vehicle attributes embedded, that can be trained by genetic algorithm (GA) based on different strategies to predict vehicle emission violation. Results show that the accuracy of predicting emission violation is as high as 92%. False determinations tend to occur for vehicles aged 7-13 years, peaking at 10 years of age.

  2. A pilot study to determine medical laser generated air contaminant emission rates for a simulated surgical procedure.

    PubMed

    Lippert, Julia F; Lacey, Steven E; Lopez, Ramon; Franke, John; Conroy, Lorraine; Breskey, John; Esmen, Nurtan; Liu, Li

    2014-01-01

    The U.S. Occupational Safety and Health Administration (OSHA) estimates that half a million health-care workers are exposed to laser surgical smoke each year. The purpose of this study was to establish a methodology to (1) estimate emission rates of laser-generated air contaminants (LGACs) using an emission chamber, and to (2) perform a screening study to differentiate the effects of three laser operational parameters. An emission chamber was designed, fabricated, and assessed for performance to estimate the emission rates of gases and particles associated with LGACs during a simulated surgical procedure. Two medical lasers (Holmium Yttrium Aluminum Garnet [Ho:YAG] and carbon dioxide [CO2]) were set to a range of plausible medical laser operational parameters in a simulated surgery to pyrolyze porcine skin generating plume in the emission chamber. Power, pulse repetition frequency (PRF), and beam diameter were evaluated to determine the effect of each operational parameter on emission rate using a fractional factorial design. The plume was sampled for particulate matter and seven gas phase combustion byproduct contaminants (benzene, ethylbenzene, toluene, formaldehyde, hydrogen cyanide, carbon dioxide, and carbon monoxide): the gas phase emission results are presented here. Most of the measured concentrations of gas phase contaminants were below their limit of detection (LOD), but detectable measurements enabled us to determine laser operation parameter influence on CO2 emissions. Confined to the experimental conditions of this screening study, results indicated that beam diameter was statistically significantly influential and power was marginally statistically significant to emission rates of CO2 when using the Ho:YAG laser but not with the carbon dioxide laser; PRF was not influential vis-a-vis emission rates of these gas phase contaminants.

  3. Utilizing vegetative environmental buffers to mitigate ammonia and particulate matter emissions from poultry houses

    USDA-ARS?s Scientific Manuscript database

    Vegetative Environmental Buffers (VEBs) are vegetation designed as a visual screen, which usually consist of trees, shrubs, grass and other potential plants. VEBs are placed around the poultry houses for the purpose of minimizing the air pollutant emissions. The expansion of the poultry industry due...

  4. BIOGENIC VOLATILE ORGANIC COMPOUND EMISSIONS FROM A LOWLAND TROPICAL WET FOREST IN COSTA RICA

    EPA Science Inventory

    Twenty common plant species were screened for emissions of biogenic volatile organic compounds (BVOCS) at a lowland tropical wet forest site in Costa Rica. Ten of the species. examined emitted substantial quantities of isoprene. These species accounted for 35-50% of the total bas...

  5. DETERMINING THE "MARGIN OF INCREMENTAL EXPOSURE": AN APPROACH TO ASSESSING NON-CANCER HEALTH EFFECTS OF DIOXINS

    EPA Science Inventory

    U.S. Environmental Protection Agency (EPA) guidance issued in April 1994 for performing screening level risk analyses of emissions from facilities that burn hazardous waste does not address the evaluation of non-cancer health effects from dioxin emissions. Historically, EPA has ...

  6. Effects of anaerobic digestion and aerobic treatment on gaseous emissions from dairy manure storages

    USDA-ARS?s Scientific Manuscript database

    Effects of anaerobic digestion and aerobic treatment on the reduction of gaseous emissions from dairy manure storages were evaluated in this study. Screened dairy manure containing 3.5% volatile solids (VS) was either anaerobically digested or aerobically treated prior to storage in air-tight vessel...

  7. Cancer Screening Test Use - United States, 2015.

    PubMed

    White, Arica; Thompson, Trevor D; White, Mary C; Sabatino, Susan A; de Moor, Janet; Doria-Rose, Paul V; Geiger, Ann M; Richardson, Lisa C

    2017-03-03

    Healthy People 2020 (HP2020) includes objectives to increase screening for breast, cervical, and colorectal cancer (1) as recommended by the U.S. Preventive Services Task Force (USPSTF).* Progress toward meeting these objectives is monitored by measuring cancer screening test use against national targets using data from the National Health Interview Survey (NHIS) (1). Analysis of 2015 NHIS data indicated that screening test use remains substantially below HP2020 targets for selected cancer screening tests. Although colorectal cancer screening test use increased from 2000 to 2015, no improvements in test use were observed for breast and cervical cancer screening. Disparities exist in screening test use by race/ethnicity, socioeconomic status, and health care access indicators. Increased measures to implement evidence-based interventions and conduct targeted outreach are needed if the HP2020 targets for cancer screening are to be achieved and the disparities in screening test use are to be reduced.

  8. Remote sensing of on-road vehicle emissions: Mechanism, applications and a case study from Hong Kong

    NASA Astrophysics Data System (ADS)

    Huang, Yuhan; Organ, Bruce; Zhou, John L.; Surawski, Nic C.; Hong, Guang; Chan, Edward F. C.; Yam, Yat Shing

    2018-06-01

    Vehicle emissions are a major contributor to air pollution in cities and have serious health impacts to their inhabitants. On-road remote sensing is an effective and economic tool to monitor and control vehicle emissions. In this review, the mechanism, accuracy, advantages and limitations of remote sensing were introduced. Then the applications and major findings of remote sensing were critically reviewed. It was revealed that the emission distribution of on-road vehicles was highly skewed so that the dirtiest 10% vehicles accounted for over half of the total fleet emissions. Such findings highlighted the importance and effectiveness of using remote sensing for in situ identification of high-emitting vehicles for further inspection and maintenance programs. However, the accuracy and number of vehicles affected by screening programs were greatly dependent on the screening criteria. Remote sensing studies showed that the emissions of gasoline and diesel vehicles were significantly reduced in recent years, with the exception of NOx emissions of diesel vehicles in spite of greatly tightened automotive emission regulations. Thirdly, the experience and issues of using remote sensing for identifying high-emitting vehicles in Hong Kong (where remote sensing is a legislative instrument for enforcement purposes) were reported. That was followed by the first time ever identification and discussion of the issue of frequent false detection of diesel high-emitters using remote sensing. Finally, the challenges and future research directions of on-road remote sensing were elaborated.

  9. Quantifying Pollutant Emissions from Office Equipment Phase IReport

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maddalena, R.L.; Destaillats, H.; Hodgson, A.T.

    2006-12-01

    Although office equipment has been a focal point for governmental efforts to promote energy efficiency through programs such as Energy Star, little is known about the relationship between office equipment use and indoor air quality. This report provides results of the first phase (Phase I) of a study in which the primary objective is to measure emissions of organic pollutants and particulate matter from a selected set of office equipment typically used in residential and office environments. The specific aims of the overall research effort are: (1) use screening-level measurements to identify and quantify the concentrations of air pollutants ofmore » interest emitted by major categories of distributed office equipment in a controlled environment; (2) quantify the emissions of air pollutants from generally representative, individual machines within each of the major categories in a controlled chamber environment using well defined protocols; (3) characterize the effects of ageing and use on emissions for individual machines spanning several categories; (4) evaluate the importance of operational factors that can be manipulated to reduce pollutant emissions from office machines; and (5) explore the potential relationship between energy consumption and pollutant emissions for machines performing equivalent tasks. The study includes desktop computers (CPU units), computer monitors, and three categories of desktop printing devices. The printer categories are: (1) printers and multipurpose devices using color inkjet technology; (2) low- to medium output printers and multipurpose devices employing monochrome or color laser technology; and (3) high-output monochrome and color laser printers. The literature review and screening level experiments in Phase 1 were designed to identify substances of toxicological significance for more detailed study. In addition, these screening level measurements indicate the potential relative importance of different categories of office equipment with respect to human exposures. The more detailed studies of the next phase of research (Phase II) are meant to characterize changes in emissions with time and may identify factors that can be modified to reduce emissions. These measurements may identify 'win-win' situations in which low energy consumption machines have lower pollutant emissions. This information will be used to compare machines to determine if some are substantially better than their peers with respect to their emissions of pollutants.« less

  10. [Results from ten years newborn hearing screening in a secondary hospital].

    PubMed

    Sequi Canet, José Miguel; Sala Langa, Maria José; Collar Del Castillo, José Ignacio

    2016-10-01

    A critical analysis is performed on the results of a newborn hearing screening program in a regional hospital. Screening results from 14,247 newborns in our maternity ward from 2002 to 2013. Two step recordings of bilateral otoacoustic emissions (initial and repeat, if failed, at about one month of life). Assessment by clinical brainstem responses. The first step was performed on 14,015 newborns (98.3% of the total) reaching the screening objective. The first step pass figures were 93.7%, which implies a good pass rate with a few patients to repeat. The second step is also good because it has a pass rate of 88.9% of newborns examined (only 0.63% of initial group needed brainstem responses assessment), but 10.6% were lost to follow up, and that is a major problem. In newborns, scheduled for brainstem responses, the loss to follow-up is worse, with a figure of 29.5%, despite the high accuracy of this test given that 69.4% of those assessed showed hearing loss. This figure represents a 0.31% of the initial group, and is a similar to that published for congenital hearing loss. Including patients that were lost to follow up this figure could be greater. Newborn hearing screening is useful but needs stronger control to avoid the follow up loss. In order to achieve this, it is crucial to have a good database and a screening coordinator. Copyright © 2015 Asociación Española de Pediatría. Publicado por Elsevier España, S.L.U. All rights reserved.

  11. Bringing the Polluters Back In: Environmental Inequality and the Organization of Chemical Production

    PubMed Central

    Grant, Don; Trautner, Mary Nell; Downey, Liam; Thiebaud, Lisa

    2011-01-01

    Environmental justice scholars have suggested that because chemical plants and other hazardous facilities emit more pollutants where they face the least resistance, disadvantaged communities face a special health risk. In trying to determine whether race or income has the bigger impact on a neighborhood’s exposure to pollution, however, scholars tend to overlook the facilities themselves and the effect of their characteristics on emissions. In particular, how do the characteristics of facilities and their surrounding communities jointly shape pollution outcomes? We propose a new line of environmental justice research that focuses on facilities and how their features combine with communities’ features to create dangerous emissions. Using novel fuzzy-set analysis techniques and the EPA’s newly developed Risk-Screening Environmental Indicators, we test the influence of facility and community factors on chemical plants’ health-threatening emissions. Contrary to the idea that community characteristics have singular, linear effects, findings show that facility and community factors combine in a variety of ways to produce risky emissions. We speculate that as chemical firms experiment with different ways of producing goods and externalizing pollution costs, new “recipes of risk” are likely to emerge. The question, then, will no longer be whether race or income matters most, but in which of these recipes do they matter and how. PMID:21921966

  12. A Smartphone App to Screen for HIV-Related Neurocognitive Impairment.

    PubMed

    Robbins, Reuben N; Brown, Henry; Ehlers, Andries; Joska, John A; Thomas, Kevin G F; Burgess, Rhonda; Byrd, Desiree; Morgello, Susan

    2014-02-01

    Neurocognitive Impairment (NCI) is one of the most common complications of HIV-infection, and has serious medical and functional consequences. However, screening for it is not routine and NCI often goes undiagnosed. Screening for NCI in HIV disease faces numerous challenges, such as limited screening tests, the need for specialized equipment and apparatuses, and highly trained personnel to administer, score and interpret screening tests. To address these challenges, we developed a novel smartphone-based screening tool, NeuroScreen , to detect HIV-related NCI that includes an easy-to-use graphical user interface with ten highly automated neuropsychological tests. To examine NeuroScreen's : 1) acceptability among patients and different potential users; 2) test construct and criterion validity; and 3) sensitivity and specificity to detect NCI. Fifty HIV+ individuals were administered a gold-standard neuropsychological test battery, designed to detect HIV-related NCI, and NeuroScreen . HIV+ test participants and eight potential provider-users of NeuroScreen were asked about its acceptability. There was a high level of acceptability of NeuroScreen by patients and potential provider-users. Moderate to high correlations between individual NeuroScreen tests and paper-and-pencil tests assessing the same cognitive domains were observed. NeuroScreen also demonstrated high sensitivity to detect NCI. NeuroScreen, a highly automated, easy-to-use smartphone-based screening test to detect NCI among HIV patients and usable by a range of healthcare personnel could help make routine screening for HIV-related NCI feasible. While NeuroScreen demonstrated robust psychometric properties and acceptability, further testing with larger and less neurocognitively impaired samples is warranted.

  13. Leaching of organic contaminants from storage of reclaimed asphalt pavement.

    PubMed

    Norin, Malin; Strömvall, A M

    2004-03-01

    Recycling of asphalt has been promoted by rapid increases in both the use and price of petroleum-based bitumen. Semi-volatile organic compounds in leachates from reclaimed asphalt pavement, measured in field samples and in laboratory column test, were analysed through a GC/MS screen-test methodology. Sixteen PAH (polyaromatic hydrocarbons) were also analysed in leachates from the column study. The highest concentrations of semi-volatile compounds, approximately 400 microg l(-1), were measured in field samples from the scarified stockpile. Naphthalene, butylated hydroxytoluene (BHT) and dibutyl phthalate (DBP) were the most dominant of the identified semi-volatiles. The occurrence of these compounds in urban groundwater, also indicate high emission rates and persistent structures of the compounds, making them potentially hazardous. Car exhausts, rubber tires and the asphalt material itself are all probable emission sources, determined from the organic contaminants released from the stockpiles. The major leaching mechanism indicated was dissolution of organic contaminants from the surface of the asphalt gravels. In the laboratory column test, the release of high-molecular weight and more toxic PAH was higher in the leachates after two years than at the commencement of storage. The concentrations of semi-volatiles in leachates, were also several times lower than those from the field stockpile. These results demonstrate the need to follow up laboratory column test with real field measurements.

  14. Preparation of a YAG:Ce phosphor glass by screen-printing technology and its application in LED packaging.

    PubMed

    Yang, Liang; Chen, Mingxiang; Lv, Zhicheng; Wang, Simin; Liu, Xiaogang; Liu, Sheng

    2013-07-01

    A simple and practical method for preparing phosphor glass is proposed. Phosphor distribution and element analysis are investigated by optical microscope and field emission scanning electron microscope (FE-SEM). The phosphor particles dispersed in the matrix are vividly observed, and their distributions are uniform. Spectrum distribution and color coordinates dependent on the thickness of the screen-printed phosphor layer coupled with a blue light emitting diode (LED) chip are studied. The luminous efficacy of the 75 μm printed phosphor-layer phosphor glass packaged white LED is 81.24 lm/W at 350 mA. This study opens up many possibilities for applications using the phosphor glass on a selected chip in which emission is well absorbed by all phosphors. The screen-printing technique also offers possibilities for the design and engineering of complex phosphor layers on glass substrates. Phosphor screen-printing technology allows the realization of high stability and thermal conductivity for the phosphor layer. This phosphor glass method provides many possibilities for LED packing, including thin-film flip chip and remote phosphor technology.

  15. How to report and interpret screening test properties: guidelines for driving researchers.

    PubMed

    Weaver, Bruce; Walter, Stephen D; Bédard, Michel

    2014-01-01

    One important goal of driving research is the development of a short but valid office-based screening test for fitness to drive of aging drivers. Several candidate tests have been proposed already, and no doubt others will be proposed in the future. It might seem obvious that authors advocating for the adoption of a particular screening test or procedure should report sensitivity, specificity, and other common screening test properties. Unfortunately, driving researchers have frequently failed to report any screening test properties. Others have reported screening test properties but have made basic mistakes such as calculating predictive values of positive and negative tests but reporting them incorrectly as sensitivity and specificity. These omissions and errors suggest that some driving researchers may be unaware of the importance of accurately reporting test properties when proposing a screening procedure and that others may need a refresher on how to calculate and interpret the most common screening test properties. Many good learning resources for screening and diagnostic tests are available, but most of them are intended for students and researchers in medicine, epidemiology, or public health. We hope that this tutorial in a prominent transportation journal will help lead to improved reporting and interpretation of screening test properties in articles that assess the usefulness of potential screening tools for fitness to drive.

  16. Fuel Flexible Gas Turbine Combustor Flametube Facility Upgraded

    NASA Technical Reports Server (NTRS)

    Little, James E.; Nemets, Steve A.; Tornabene, Robert T.; Smith, Timothy D.; Frankenfeld, Bruce J.

    2004-01-01

    In fiscal year 2003, test cell 23 of the Research Combustion Laboratory (RCL 23) at the NASA Glenn Research Center was upgraded with the addition of gaseous hydrogen as a working propellant and the addition of a 450-psig air-supply system. Test flexibility was further enhanced by upgrades to the facility control systems. RCL 23 can now test with gaseous hydrogen flow rates up to 0.05 lbm/sec and jet fuel flow rates up to 0.62 lbm/sec. Research airflow rates up to 3 lbm/sec are possible with the 450-psig supply system over a range of inlet temperatures. Nonvitiated, heated air is supplied from a shell and tube heat exchanger. The maximum nonvitiated facility air temperature is 1100 F at 1.5 lbm/sec. Research-section exhaust temperatures are limited to 3200 F because of material and cooling capacity limits. A variety of support systems are available depending on the research hardware configuration. Test section ignition can be provided via either a hydrogen air torch system or an electronic spark system. Emissions measurements are obtained with either pneumatically or electromechanically actuated gas sample probes, and the electromechanical system allows for radial measurements at a user-specified axial location for measurement of emissions profiles. Gas analysis data can be obtained for a variety of species, including carbon monoxide (CO), carbon dioxide (CO2), nitrogen oxides (NO and NOx), oxygen (O2), unburnt hydrocarbons, and unburnt hydrogen. Facility control is accomplished with a programmable logic control system. Facility operations have been upgraded to a system based on graphical user interface control screens. A data system is available for real-time acquisition and monitoring of both measurements in engineering units and performance calculations. The upgrades have made RCL 23 a highly flexible facility for research into low emissions gas turbine combustor concepts, and the flame tube configuration inherently allows for a variety of fuel nozzle configurations to be tested in a cost-effective manner. RCL 23 is poised to be a leading facility for developing modern low-emission fuel nozzles for use with jet fuel and alternative fuels.

  17. Combinatorial fabrication and screening of organic light-emitting device arrays

    NASA Astrophysics Data System (ADS)

    Shinar, Joseph; Shinar, Ruth; Zhou, Zhaoqun

    2007-11-01

    The combinatorial fabrication and screening of 2-dimensional (2-d) small molecular UV-violet organic light-emitting device (OLED) arrays, 1-d blue-to-red arrays, 1-d intense white OLED libraries, 1-d arrays to study Förster energy transfer in guest-host OLEDs, and 2-d arrays to study exciplex emission from OLEDs is described. The results demonstrate the power of combinatorial approaches for screening OLED materials and configurations, and for studying their basic properties.

  18. Screening of trace elements in hair of the female population with different types of cancers in Wielkopolska region of Poland.

    PubMed

    Czerny, Bogusław; Krupka, Krzysztof; Ożarowski, Marcin; Seremak-Mrozikiewicz, Agnieszka

    2014-01-01

    Cancer constitutes a major health problem worldwide. Thus, search for reliable and practical markers of the disease process remains the key issue of the diagnostic process. The study aims at linking the trace element status of an organism, assessed by hair analysis, with the occurrence of cancer diseases. Hair samples were collected from 299 patients with cancer diseases confirmed by a histopathological test and from 100 controls. Cancer patients were divided into three groups, depending on cancer type: hormone-dependent cancer, cancer of the alimentary tract, and cancer with high glycolytic activity. Mineral element analysis of hair was performed using an atomic emission spectrophotometer with inductively coupled plasma (ICP-OES) and inductively coupled plasma mass spectrometry (ICP-MS). Statistically significantly lower concentrations of selenium, zinc, copper, germanium and boron, iron, and magnesium were observed in the three groups of cancer patients. Disturbance in the axis glucose-insulin and changes in concentrations of heavy metals and toxic elements were also noted. It seems safe to conclude that our results confirmed usefulness of hair element analysis in screening tests for the assessment of the biomarker of various cancer diseases in a female population.

  19. Alternative Fuel Research in Fischer-Tropsch Synthesis

    NASA Technical Reports Server (NTRS)

    Surgenor, Angela D.; Klettlinger, Jennifer L.; Yen, Chia H.; Nakley, Leah M.

    2011-01-01

    NASA Glenn Research Center has recently constructed an Alternative Fuels Laboratory which is solely being used to perform Fischer-Tropsch (F-T) reactor studies, novel catalyst development and thermal stability experiments. Facility systems have demonstrated reliability and consistency for continuous and safe operations in Fischer-Tropsch synthesis. The purpose of this test facility is to conduct bench scale Fischer-Tropsch (F-T) catalyst screening experiments while focusing on reducing energy inputs, reducing CO2 emissions and increasing product yields within the F-T process. Fischer-Tropsch synthesis is considered a gas to liquid process which reacts syn-gas (a gaseous mixture of hydrogen and carbon monoxide), over the surface of a catalyst material which is then converted into liquids of various hydrocarbon chain length and product distributions1. These hydrocarbons can then be further processed into higher quality liquid fuels such as gasoline and diesel. The experiments performed in this laboratory will enable the investigation of F-T reaction kinetics to focus on newly formulated catalysts, improved process conditions and enhanced catalyst activation methods. Currently the facility has the capability of performing three simultaneous reactor screening tests, along with a fourth fixed-bed reactor used solely for cobalt catalyst activation.

  20. To Screen or Not to Screen? The Benefits and Harms of Screening Tests

    MedlinePlus

    ... issue To Screen or Not to Screen? The Benefits and Harms of Screening Tests En español Send ... test, talk with your doctor about the possible benefits and harms to help you decide what’s best ...

  1. Evaluating the Environmental Impacts of a Nano-Enhanced Field Emission Display Using Life Cycle Assessment: A Screening-Level Study

    EPA Science Inventory

    Carbon nanotube (CNT) field emission displays (FEDs) are currently in the product development stage and are expected to be commercialized in the near future because they offer image quality and viewing angles comparable to a cathode ray tube (CRT) while using a thinner structure,...

  2. 40 CFR 63.420 - Applicability.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...-CE)+0.17 (TE)+0.08(TES)+0.038(TI)+8.5×10-6(C)+KQ]+0.04(OE) where: ET = emissions screening factor for... efficiency limitation on potential to emit for the vapor processing system used to control emissions from... of external floating roof gasoline storage vessels with only primary seals; TES = total number of...

  3. 40 CFR 63.420 - Applicability.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...-CE)+0.17 (TE)+0.08(TES)+0.038(TI)+8.5×10-6(C)+KQ]+0.04(OE) where: ET = emissions screening factor for... efficiency limitation on potential to emit for the vapor processing system used to control emissions from... of external floating roof gasoline storage vessels with only primary seals; TES = total number of...

  4. 40 CFR 63.420 - Applicability.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...-CE)+0.17 (TE)+0.08(TES)+0.038(TI)+8.5×10-6(C)+KQ]+0.04(OE) where: ET = emissions screening factor for... efficiency limitation on potential to emit for the vapor processing system used to control emissions from... of external floating roof gasoline storage vessels with only primary seals; TES = total number of...

  5. 40 CFR 63.420 - Applicability.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...-CE)+0.17 (TE)+0.08(TES)+0.038(TI)+8.5×10-6(C)+KQ]+0.04(OE) where: ET = emissions screening factor for... efficiency limitation on potential to emit for the vapor processing system used to control emissions from... of external floating roof gasoline storage vessels with only primary seals; TES = total number of...

  6. 40 CFR 63.420 - Applicability.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...)(1-CE)+0.17 (TE)+0.08(TES)+0.038(TI)+8.5×10-6(C)+KQ]+0.04(OE) where: ET = emissions screening factor... efficiency limitation on potential to emit for the vapor processing system used to control emissions from... of external floating roof gasoline storage vessels with only primary seals; TES = total number of...

  7. Reactive trace gas emissions from stressed plants: a poorly characterized major source of atmospheric volatiles

    NASA Astrophysics Data System (ADS)

    Niinemets, Ülo

    2017-04-01

    Vegetation constitutes the greatest source of reactive volatile organic compounds in the atmosphere. The current emission estimates primarily rely on constitutive emissions that are present only in some plant species. However, all plant species can be induced to emit reactive volatiles by different abiotic and biotic stresses, but the stress-dependent emissions have been largely neglected in emission measurements and models. This presentation provides an overview of systematic screening of stress-dependent volatile emissions from a broad range of structurally and physiologically divergent plant species from temperate to tropical ecosystems. Ozone, heat, drought and wounding stress were the abiotic stresses considered in the screening, while biotic stress included herbivory, chemical elicitors simulating herbivory and fungal infections. The data suggest that any moderate to severe stress leads to significant emissions of a rich blend of volatiles, including methanol, green leaf volatiles (the lipoxygenase pathway volatiles, dominated by C6 aldehydes, alcohols and derivatives), different mono- and sesquiterpenes and benzenoids. The release of volatiles occurs in stress severity-dependent manner, although the emission responses are often non-linear with more severe stresses resulting in disproportionately greater emissions. Stress volatile release is induced in both non-constitutive and constitutive volatile emitters, whereas the rate of constitutive volatile emissions in constitutive emitters is often reduced under environmental and biotic stresses. Given that plants in natural conditions often experience stress, this analysis suggests that global volatile emissions have been significantly underestimated. Furthermore, in globally changing hotter climates, the frequency and severity of both abiotic and biotic stresses is expected to increase. Thus, the stress-induced volatile emissions are predicted to play a dominant role in plant-atmosphere interactions in near future. Quantitative models that link stress severity, plant volatile emissions and climatic feedbacks are currently being developed, and this presentation argues that incorporating stress-dependent feedbacks in Earth system models in inevitable to simulate future climates.

  8. A Smartphone App to Screen for HIV-Related Neurocognitive Impairment

    PubMed Central

    Robbins, Reuben N.; Brown, Henry; Ehlers, Andries; Joska, John A.; Thomas, Kevin G.F.; Burgess, Rhonda; Byrd, Desiree; Morgello, Susan

    2014-01-01

    Background Neurocognitive Impairment (NCI) is one of the most common complications of HIV-infection, and has serious medical and functional consequences. However, screening for it is not routine and NCI often goes undiagnosed. Screening for NCI in HIV disease faces numerous challenges, such as limited screening tests, the need for specialized equipment and apparatuses, and highly trained personnel to administer, score and interpret screening tests. To address these challenges, we developed a novel smartphone-based screening tool, NeuroScreen, to detect HIV-related NCI that includes an easy-to-use graphical user interface with ten highly automated neuropsychological tests. Aims To examine NeuroScreen’s: 1) acceptability among patients and different potential users; 2) test construct and criterion validity; and 3) sensitivity and specificity to detect NCI. Methods Fifty HIV+ individuals were administered a gold-standard neuropsychological test battery, designed to detect HIV-related NCI, and NeuroScreen. HIV+ test participants and eight potential provider-users of NeuroScreen were asked about its acceptability. Results There was a high level of acceptability of NeuroScreen by patients and potential provider-users. Moderate to high correlations between individual NeuroScreen tests and paper-and-pencil tests assessing the same cognitive domains were observed. NeuroScreen also demonstrated high sensitivity to detect NCI. Conclusion NeuroScreen, a highly automated, easy-to-use smartphone-based screening test to detect NCI among HIV patients and usable by a range of healthcare personnel could help make routine screening for HIV-related NCI feasible. While NeuroScreen demonstrated robust psychometric properties and acceptability, further testing with larger and less neurocognitively impaired samples is warranted. PMID:24860624

  9. Quantum cascade laser-based screening portal for the detection of explosive precursors

    NASA Astrophysics Data System (ADS)

    Lindley, Ruth; Normand, Erwan; Howieson, Iain; McCulloch, Michael; Black, Paul; Lewis, Colin; Foulger, Brian

    2007-10-01

    In recent years, quantum cascade lasers (QCL) have been proven in robust, high-performance gas analyzers designed for continuous emission monitoring (CEM) in harsh environments. In 2006, Cascade Technologies reported progress towards adapting its patented technology for homeland security applications by publishing initial results on explosive compound detection. This paper presents the performance and results from a QCL-based people screening portal developed during the past year and aimed at the detection of precursors used in the make up of improvised explosive devices (IED). System tests have been carried out on a large number of potential interferents, together with target precursor materials, reinforcing original assumptions that compound fingerprinting can be effectively demonstrated using this technique. Results have shown that an extremely high degree of specificity can be achieved with a sub-second response time. Furthermore, it has been shown that unambiguous precursor signature recognition can be extended to compound mixtures associated with the intermediate stages in the make up of IEDs, whilst maintaining interferent immunity. The portal sensitivity was configured for parts per billion (ppb) detection level thresholds, but is currently being reconfigured for sub-ppb detection. In summary, the results obtained from the QCL based portal indicate that development of a low cost detection system, with enhanced features such as low false positive and high throughput screening of individuals or items, is possible. Development and testing was carried out with the support of the UK government.

  10. A pilot study of indoor air quality in screen golf courses.

    PubMed

    Goung, Sun-Ju Nam; Yang, Jinho; Kim, Yoon Shin; Lee, Cheol Min

    2015-05-01

    The aims of this study were to provide basic data for determining policies on air quality for multi-user facilities, including the legal enrollment of the indoor air quality regulation as designated by the Ministry of Environment, and to establish control plans. To this end, concentrations of ten pollutants (PM10, carbon monoxide (CO), carbon dioxide (CO2), nitrogen dioxide (NO2), formaldehyde (HCHO), total volatile organic compounds (TVOCs), radon (Rn), oxone (O3), total bacteria counts (TBC), and asbestos) in addition to nicotine, a smoking index material used to determine the impact of smoking on the air quality, were investigated in indoor game rooms and lobbies of 64 screen golf courses. The average concentration of none of the ten pollutants in the game rooms and lobbies of screen golf courses was found to exceed the limit set by the law. There were, however, pollutant concentrations exceeding limits in some screen golf courses, in order to establish a control plan for the indoor air quality of screen golf courses, a study on the emission sources of each pollutant was conducted. The major emission sources were found to be facility users' activities such as smoking and the use of combustion appliances, building materials, and finishing materials.

  11. 40 CFR 61.13 - Emission tests and waiver of emission tests.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 8 2010-07-01 2010-07-01 false Emission tests and waiver of emission tests. 61.13 Section 61.13 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS General Provisions § 61.13 Emission tests and waiver of emission tests....

  12. Prostate Cancer Screening

    MedlinePlus

    ... decrease the risk of dying from cancer. Scientists study screening tests to find those with the fewest risks and ... or routine screening test for prostate cancer. Screening tests for prostate cancer are under study, and there are screening clinical trials taking place ...

  13. Pollution reduction technology program for turboprop engines

    NASA Technical Reports Server (NTRS)

    Tomlinson, J. G.

    1977-01-01

    The reduction of CO, HC, and smoke emissions while maintaining acceptable NO(x) emissions without affecting fuel consumption, durability, maintainability, and safety was accomplished. Component combustor concept screening directed toward the demonstration of advanced combustor technology required to meet the EPA exhaust emissions standards for class P2 turboprop engines was covered. The combustion system for the Allison 501-D22A engine was used, and three combustor design concepts - reverse flow, prechamber, and staged fuel were evaluated.

  14. A Comparison of Parallel and Integrated Models for Implementation of Routine HIV Screening in a Large, Urban Emergency Department.

    PubMed

    Hankin, Abigail; Freiman, Heather; Copeland, Brittney; Travis, Natasha; Shah, Bijal

    2016-01-01

    This study compared two approaches for implementation of non-targeted HIV screening in the emergency department (ED): (1) designated HIV counselors screening in parallel with ED care and (2) nurse-based screening integrated into patient triage. A retrospective analysis was performed to compare parallel and integrated screening models using data from the first 12 months of each program. Data for the parallel screening model were extracted from information collected by HIV test counselors and the electronic medical record (EMR). Integrated screening model data were extracted from the EMR and supplemented by data collected by HIV social workers during patient interaction. For both programs, data included demographics, HIV test offer, test acceptance or declination, and test result. A Z-test between two proportions was performed to compare screening frequencies and results. During the first 12 months of parallel screening, approximately 120,000 visits were made to the ED, with 3,816 (3%) HIV tests administered and 65 (2%) new diagnoses of HIV infection. During the first 12 months of integrated screening, 111,738 patients were triaged in the ED, with 16,329 (15%) patients tested and 190 (1%) new diagnoses. Integrated screening resulted in an increased frequency of HIV screening compared with parallel screening (0.15 tests per ED patient visit vs. 0.03 tests per ED patient visit, p<0.001) and an increase in the absolute number of new diagnoses (190 vs. 65), representing a slight decrease in the proportion of new diagnoses (1% vs. 2%, p=0.007). Non-targeted, integrated HIV screening, with test offer and order by ED nurses during patient triage, is feasible and resulted in an increased frequency of HIV screening and a threefold increase in the absolute number of newly identified HIV-positive patients.

  15. Risks of Prostate Cancer Screening

    MedlinePlus

    ... decrease the risk of dying from cancer. Scientists study screening tests to find those with the fewest risks and ... or routine screening test for prostate cancer. Screening tests for prostate cancer are under study, and there are screening clinical trials taking place ...

  16. Leaf level emissions of volatile organic compounds (VOC) from some Amazonian and Mediterranean plants

    NASA Astrophysics Data System (ADS)

    Bracho-Nunez, A.; Knothe, N. M.; Welter, S.; Staudt, M.; Costa, W. R.; Liberato, M. A. R.; Piedade, M. T. F.; Kesselmeier, J.

    2012-11-01

    As volatile organic compounds (VOCs) significantly affect atmospheric chemistry (oxidative capacity) and physics (secondary organic aerosol formation and effects), emission inventories defining regional and global biogenic VOC emission strengths are important. The aim of this work was to achieve a description of VOC emissions from poorly described tropical vegetation to be compared with the quite well investigated and highly heterogeneous emissions from Mediterranean vegetation. For this task, common plant species of both ecosystems were investigated. Sixteen plant species from the Mediterranean area, which is known for its special diversity in VOC emitting plant species, were chosen. In contrast, little information is currently available regarding emissions of VOCs from tropical tree species at the leaf level. Twelve plant species from different environments of the Amazon basin, i.e. Terra firme, Várzea and Igapó, were screened for emission of VOCs at leaf level with a branch enclosure system. Analysis of the volatile organics was performed online by a proton-transfer-reaction mass spectrometer (PTR-MS) and offline by collection on adsorbent tubes and subsequent gas chromatographic analysis. Isoprene was quantitatively the most dominant compound emitted followed by monoterpenes, methanol and acetone. Most of the Mediterranean species emitted a variety of monoterpenes, whereas only five tropical species were monoterpene emitters exhibiting a quite conservative emission pattern (α-pinene > limonene > sabinene > β-pinene). Mediterranean plants showed additional emissions of sesquiterpenes, whereas in the case of plants from the Amazon region no sesquiterpenes were detected probably due to a lack of sensitivity in the measuring systems. On the other hand methanol emissions, an indicator of growth, were common in most of the tropical and Mediterranean species. A few species from both ecosystems showed acetone emissions. The observed heterogeneous emissions including reactive VOC species which are not easily detected by flux measurements, give reason to perform more screening at leaf level and, whenever possible, within the forests under ambient conditions.

  17. Breast, prostate, and thyroid cancer screening tests and overdiagnosis.

    PubMed

    Jung, Minsoo

    The purpose of this study was to examine overdiagnosis and overtreatment related to cancer screening and to review relevant reports and studies. A comprehensive search of peer-reviewed and gray literature was conducted for relevant studies published between January 2000 and December 2015 reporting breast, prostate, and thyroid cancer screening tests and overdiagnosis. This study revealed no dichotomy on where screening would lower risk or cause overdiagnosis and overtreatment. Many screening tests did both, that is, at population level, there were both benefit (decreased disease-specific mortality) and harm (overdiagnosis and overtreatment). Therefore, we need to consider a balanced argument with citations for the potential benefits of screening along with the harms associated with screening. Although the benefits and harms can only be tested through randomized trials, important data from cohort studies, diagnostic accuracy studies, and modeling work can help define the extent of benefits and harms in the population. The health care cycle that prompt patients to undergo periodic screening tests is self-reinforcing. In most developed countries, screening test recommendations encourage periodic testing. Therefore, patients are continuing their screening. It is necessary for patients to become wise consumers of screening tests and make decisions with their physicians regarding further testing and treatments. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. Estimating the Impacts of Direct Load Control Programs Using GridPIQ, a Web-Based Screening Tool

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pal, Seemita; Thayer, Brandon L.; Barrett, Emily L.

    In direct load control (DLC) programs, utilities can curtail the demand of participating loads to contractually agreed-upon levels during periods of critical peak load, thereby reducing stress on the system, generation cost, and required transmission and generation capacity. Participating customers receive financial incentives. The impacts of implementing DLC programs extend well beyond peak shaving. There may be a shift of load proportional to the interrupted load to the times before or after a DLC event, and different load shifts have different consequences. Tools that can quantify the impacts of such programs on load curves, peak demand, emissions, and fossil fuelmore » costs are currently lacking. The Grid Project Impact Quantification (GridPIQ) screening tool includes a Direct Load Control module, which takes into account project-specific inputs as well as the larger system context in order to quantify the impacts of a given DLC program. This allows users (utilities, researchers, etc.) to test and compare different program specifications and their impacts.« less

  19. Cancer Screening: How Do Screening Tests Become Standard Tests?

    MedlinePlus

    ... more groups. The people in one group (the control group ) may be given a standard screening test (if one exists) or no screening test. The ... for the human papillomavirus (HPV) and those who test negative for HPV. The ... Case-control studies Case-control studies are like cohort studies ...

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    M. L. Abbott; K. N. Keck; R. E. Schindler

    This screening level risk assessment evaluates potential adverse human health and ecological impacts resulting from continued operations of the calciner at the New Waste Calcining Facility (NWCF) at the Idaho Nuclear Technology and Engineering Center (INTEC), Idaho National Engineering and Environmental Laboratory (INEEL). The assessment was conducted in accordance with the Environmental Protection Agency (EPA) report, Guidance for Performing Screening Level Risk Analyses at Combustion Facilities Burning Hazardous Waste. This screening guidance is intended to give a conservative estimate of the potential risks to determine whether a more refined assessment is warranted. The NWCF uses a fluidized-bed combustor to solidifymore » (calcine) liquid radioactive mixed waste from the INTEC Tank Farm facility. Calciner off volatilized metal species, trace organic compounds, and low-levels of radionuclides. Conservative stack emission rates were calculated based on maximum waste solution feed samples, conservative assumptions for off gas partitioning of metals and organics, stack gas sampling for mercury, and conservative measurements of contaminant removal (decontamination factors) in the off gas treatment system. Stack emissions were modeled using the ISC3 air dispersion model to predict maximum particulate and vapor air concentrations and ground deposition rates. Results demonstrate that NWCF emissions calculated from best-available process knowledge would result in maximum onsite and offsite health and ecological impacts that are less then EPA-established criteria for operation of a combustion facility.« less

  1. Improving compliance to colorectal cancer screening using blood and stool based tests in patients refusing screening colonoscopy in Germany.

    PubMed

    Adler, Andreas; Geiger, Sebastian; Keil, Anne; Bias, Harald; Schatz, Philipp; deVos, Theo; Dhein, Jens; Zimmermann, Mathias; Tauber, Rudolf; Wiedenmann, Bertram

    2014-10-17

    Despite strong recommendations for colorectal cancer (CRC) screening, participation rates are low. Understanding factors that affect screening choices is essential to developing future screening strategies. Therefore, this study assessed patient willingness to use non-invasive stool or blood based screening tests after refusing colonoscopy. Participants were recruited during regular consultations. Demographic, health, psychological and socioeconomic factors were recorded. All subjects were advised to undergo screening by colonoscopy. Subjects who refused colonoscopy were offered a choice of non-invasive tests. Subjects who selected stool testing received a collection kit and instructions; subjects who selected plasma testing had a blood draw during the office visit. Stool samples were tested with the Hb/Hp Complex Elisa test, and blood samples were tested with the Epi proColon® 2.0 test. Patients who were positive for either were advised to have a diagnostic colonoscopy. 63 of 172 subjects were compliant to screening colonoscopy (37%). 106 of the 109 subjects who refused colonoscopy accepted an alternative non-invasive method (97%). 90 selected the Septin9 blood test (83%), 16 selected a stool test (15%) and 3 refused any test (3%). Reasons for blood test preference included convenience of an office draw, overall convenience and less time consuming procedure. 97% of subjects refusing colonoscopy accepted a non-invasive screening test of which 83% chose the Septin9 blood test. The observation that participation can be increased by offering non-invasive tests, and that a blood test is the preferred option should be validated in a prospective trial in the screening setting.

  2. Hearing impairment in premature newborns—Analysis based on the national hearing screening database in Poland

    PubMed Central

    Greczka, Grazyna; Dabrowski, Piotr; Szyfter-Harris, Joanna; Mazela, Jan

    2017-01-01

    Objectives The incidence of sensorineural hearing loss is between 1 and 3 per 1000 in healthy neonates and 2–4 per 100 in high-risk infants. The national universal neonatal hearing screening carried out in Poland since 2002 enables selection of infants with suspicion and/or risk factors of hearing loss. In this study, we assessed the incidence and risk factors of hearing impairment in infants ≤33 weeks’ gestational age (wga). Methods We analyzed the database of the Polish Universal Newborns Hearing Screening Program from 2010 to 2013. The study group involved 11438 infants born before 33 wga, the control group—1487730 infants. Screening was performed by means of transient evoked otoacoustic emissions. The risk factors of hearing loss were recorded. Infants who failed the screening test and/or had risk factors were referred for further audiological evaluation. Results Hearing deficit was diagnosed in 11% of infants ≤25 wga, 5% at 26–27 wga, 3.46% at 28 wga and 2–3% at 29–32 wga. In the control group the incidence of hearing deficit was 0.2% (2.87% with risk factors). The most important risk factors were craniofacial malformations, very low birth weight, low Apgar score and mechanical ventilation. Hearing screening was positive in 22.42% newborns ≤28 wga and 10% at 29–32 wga and in the control group. Conclusions Hearing impairment is a severe consequence of prematurity. Its prevalence is inversely related to the maturity of the baby. Premature infants have many concomitant risk factors which influence the occurrence of hearing deficit. PMID:28910311

  3. Adherence to multiple cancer screening tests among women living in Appalachia Ohio

    PubMed Central

    Katz, Mira L.; Reiter, Paul L.; Young, Gregory S.; Pennell, Michael L.; Tatum, Cathy M.; Paskett, Electra D.

    2015-01-01

    Background There is a lack of information about the correlates of completing all three cancer screening tests among women living in Appalachia. Methods Cross-sectional telephone interviews were conducted (April-September 2013) among women (n=637) ages 51-75 from 12 Appalachia Ohio counties. Outcomes of within screening guidelines were verified by medical record. Multivariable logistic regression models identified correlates of being within guidelines for all three cancer screening tests. Results Screening rates were: mammography (32.1%), Pap test (36.1%), and a colorectal cancer test (30.1%). Only 8.6% of women were within guidelines for all tests. Having had a check-up in the past two years and having received a screening recommendation were significantly related to being within guidelines for all three tests (p<0.01). Participants with higher annual household incomes ($60,000+; OR=3.53, 95% CI: 1.49, 8.33) and conditions requiring regular medical visits (OR=3.16, 95% CI: 1.29, 7.74) were more likely to be within guidelines for all three screening tests. Conclusion Less than 10% of women had completed screening within guidelines for all three screening tests. Regular contact with the healthcare system and higher incomes were significant predictors of being within guidelines. Impact Within guidelines rates for the three recommended cancer screening tests is low among women in Appalachia Ohio. This finding illustrates the need for innovative interventions to improve rates of multiple cancer screening tests. PMID:26282630

  4. Incorporating DNA Sequencing into Current Prenatal Screening Practice for Down's Syndrome

    PubMed Central

    Wald, Nicholas J.; Bestwick, Jonathan P.

    2013-01-01

    Background Prenatal screening for Down's syndrome is performed using biochemical and ultrasound markers measured in early pregnancy such as the Integrated test using first and second trimester markers. Recently, DNA sequencing methods have been introduced on free DNA in maternal plasma, yielding a high screening performance. These methods are expensive and there is a test failure rate. We determined the screening performance of merging the Integrated test with the newer DNA techniques in a protocol that substantially reduces the cost compared with universal DNA testing and still achieves high screening performance with no test failures. Methods Published data were used to model screening performance of a protocol in which all women receive the first stage of the Integrated test at about 11 weeks of pregnancy. On the basis of this higher risk women have reflex DNA testing and lower risk women as well as those with a failed DNA test complete the Integrated test at about 15 weeks. Results The overall detection rate was 95% with a 0.1% false-positive rate if 20% of women were selected to receive DNA testing. If all women had DNA testing the detection rate would be 3 to 4 percentage points higher with a false-positive rate 30 times greater if women with failed tests were treated as positive and offered a diagnostic amniocentesis, or 3 times greater if they had a second trimester screening test (Quadruple test) and treated as positive only if this were positive. The cost per women screened would be about one-fifth, compared with universal DNA testing, if the DNA test were 20 times the cost of the Integrated test. Conclusion The proposed screening protocol achieves a high screening performance without programme test failures and at a substantially lower cost than offering all women DNA testing. PMID:23527014

  5. Is maternal plasma DNA testing impacting serum-based screening for aneuploidy in the United States?

    PubMed

    Palomaki, Glenn E; Ashwood, Edward R; Best, Robert G; Lambert-Messerlian, Geralyn; Knight, George J

    2015-11-01

    We sought to determine whether tests for fetal aneuploidy based on next-generation sequencing of cell-free DNA in maternal circulation have had an impact on routine serum-based screening in the general pregnant population. We compared results from laboratory surveys in 2011 and 2014 that reported types of prenatal serum screening tests and numbers of tests performed. Testing records from two prenatal serum screening laboratories examined temporal trends in the proportion of screened women 35 years of age and older from 2008 (or 2009) to 2014. The 82 laboratory survey results available for comparison showed that 1.7 million women were screened in 2014, a 5% increase over 2011. In the two screening laboratories, the proportion of screened women age 35 and older increased for several years but then experienced reductions of 8 and 18% by mid-2014 when compared with the highest rates observed. As of 2014, maternal plasma DNA testing appears to have had only a minor impact on serum screening rates in the United States. Ongoing surveillance has the potential to determine if, and when, DNA testing begins to replace serum testing as a primary screen for Down syndrome in the United States.

  6. Testing and screening for chlamydia in general practice: a cross-sectional analysis.

    PubMed

    Thomson, Allison; Morgan, Simon; Henderson, Kim; Tapley, Amanda; Spike, Neil; Scott, John; van Driel, Mieke; Magin, Parker

    2014-12-01

    Chlamydia screening is widely advocated. General practice registrars are an important stage of clinical behaviour development. This study aimed to determine rates of, and factors associated with, registrars' chlamydia testing including asymptomatic screening. A cross-sectional analysis of data from Registrars Clinical Encounters in Training (ReCEnT), a cohort study of registrars' consultations. Registrars record details of 60 consecutive consultations in each GP-term of training. Outcome factors were chlamydia testing, asymptomatic screening and doctor-initiated screening. Testing occurred in 2.5% of 29,112 consultations (398 registrars) and in 5.8% of patients aged 15-25. Asymptomatic screening comprised 47.5% of chlamydia tests, and 55.6% of screening tests were doctor-initiated. Chlamydia testing was associated with female gender of doctor and patient, younger patient age, and patients new to doctor or practice. Asymptomatic screening was associated with practices where patients incur no fees, and in patients new to doctor or practice. Screening of female patients was more often doctor-initiated. GP registrars screen for chlamydia disproportionately in younger females and new patients. Our findings highlight potential opportunities to improve uptake of screening for chlamydia, including targeted education and training for registrars, campaigns targeting male patients, and addressing financial barriers to accessing screening services. © 2014 Public Health Association of Australia.

  7. The effect of presenting information about invasive follow-up testing on individuals' noninvasive colorectal cancer screening participation decision: results from a discrete choice experiment.

    PubMed

    Benning, Tim M; Dellaert, Benedict G C; Severens, Johan L; Dirksen, Carmen D

    2014-07-01

    Many national colorectal cancer screening campaigns have a similar structure. First, individuals are invited to take a noninvasive screening test, and, second, in the case of a positive screening test result, they are advised to undergo a more invasive follow-up test. The objective of this study was to investigate how much individuals' participation decision in noninvasive screening is affected by the presence or absence of detailed information about invasive follow-up testing and how this effect varies over screening tests. We used a labeled discrete choice experiment of three noninvasive colorectal cancer screening types with two versions that did or did not present respondents with detailed information about the possible invasive follow-up test (i.e., colonoscopy) and its procedure. We used data from 631 Dutch respondents aged 55 to 75 years. Each respondent received only one of the two versions (N = 310 for the invasive follow-up test information specification version, and N = 321 for the no-information specification version). Mixed logit model results show that detailed information about the invasive follow-up test negatively affects screening participation decisions. This effect can be explained mainly by a decrease in choice shares for the most preferred screening test (a combined stool and blood sample test). Choice share simulations based on the discrete choice experiment indicated that presenting invasive follow-up test information decreases screening participation by 4.79%. Detailed information about the invasive follow-up test has a negative effect on individuals' screening participation decisions in noninvasive colorectal cancer screening campaigns. This result poses new challenges for policymakers who aim not only to increase uptake but also to provide full disclosure to potential screening participants. Copyright © 2014 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  8. Abnormal Cervical Cancer Screening Test Results

    MedlinePlus

    ... FAQ187 GYNECOLOGIC PROBLEMS Abnormal Cervical Cancer Screening Test Results • What is cervical cancer screening? • What causes abnormal cervical cancer screening test results? • What is the difference between the terms cervical ...

  9. Recommendations for a step‐wise comparative approach to the evaluation of new screening tests for colorectal cancer

    PubMed Central

    Senore, Carlo; Mandel, Jack S.; Allison, James E.; Atkin, Wendy S.; Benamouzig, Robert; Bossuyt, Patrick M. M.; Silva, Mahinda De; Guittet, Lydia; Halloran, Stephen P.; Haug, Ulrike; Hoff, Geir; Itzkowitz, Steven H.; Leja, Marcis; Levin, Bernard; Meijer, Gerrit A.; O'Morain, Colm A.; Parry, Susan; Rabeneck, Linda; Rozen, Paul; Saito, Hiroshi; Schoen, Robert E.; Seaman, Helen E.; Steele, Robert J. C.; Sung, Joseph J. Y.; Winawer, Sidney J.

    2016-01-01

    BACKGROUND New screening tests for colorectal cancer continue to emerge, but the evidence needed to justify their adoption in screening programs remains uncertain. METHODS A review of the literature and a consensus approach by experts was undertaken to provide practical guidance on how to compare new screening tests with proven screening tests. RESULTS Findings and recommendations from the review included the following: Adoption of a new screening test requires evidence of effectiveness relative to a proven comparator test. Clinical accuracy supported by programmatic population evaluation in the screening context on an intention‐to‐screen basis, including acceptability, is essential. Cancer‐specific mortality is not essential as an endpoint provided that the mortality benefit of the comparator has been demonstrated and that the biologic basis of detection is similar. Effectiveness of the guaiac‐based fecal occult blood test provides the minimum standard to be achieved by a new test. A 4‐phase evaluation is recommended. An initial retrospective evaluation in cancer cases and controls (Phase 1) is followed by a prospective evaluation of performance across the continuum of neoplastic lesions (Phase 2). Phase 3 follows the demonstration of adequate accuracy in these 2 prescreening phases and addresses programmatic outcomes at 1 screening round on an intention‐to‐screen basis. Phase 4 involves more comprehensive evaluation of ongoing screening over multiple rounds. Key information is provided from the following parameters: the test positivity rate in a screening population, the true‐positive and false‐positive rates, and the number needed to colonoscope to detect a target lesion. CONCLUSIONS New screening tests can be evaluated efficiently by this stepwise comparative approach. Cancer 2016;122:826–39. © 2016 The Authors. Cancer published by Wiley Periodicals, Inc. on behalf of American Cancer Society. PMID:26828588

  10. Recommendations for a step-wise comparative approach to the evaluation of new screening tests for colorectal cancer.

    PubMed

    Young, Graeme P; Senore, Carlo; Mandel, Jack S; Allison, James E; Atkin, Wendy S; Benamouzig, Robert; Bossuyt, Patrick M M; Silva, Mahinda De; Guittet, Lydia; Halloran, Stephen P; Haug, Ulrike; Hoff, Geir; Itzkowitz, Steven H; Leja, Marcis; Levin, Bernard; Meijer, Gerrit A; O'Morain, Colm A; Parry, Susan; Rabeneck, Linda; Rozen, Paul; Saito, Hiroshi; Schoen, Robert E; Seaman, Helen E; Steele, Robert J C; Sung, Joseph J Y; Winawer, Sidney J

    2016-03-15

    New screening tests for colorectal cancer continue to emerge, but the evidence needed to justify their adoption in screening programs remains uncertain. A review of the literature and a consensus approach by experts was undertaken to provide practical guidance on how to compare new screening tests with proven screening tests. Findings and recommendations from the review included the following: Adoption of a new screening test requires evidence of effectiveness relative to a proven comparator test. Clinical accuracy supported by programmatic population evaluation in the screening context on an intention-to-screen basis, including acceptability, is essential. Cancer-specific mortality is not essential as an endpoint provided that the mortality benefit of the comparator has been demonstrated and that the biologic basis of detection is similar. Effectiveness of the guaiac-based fecal occult blood test provides the minimum standard to be achieved by a new test. A 4-phase evaluation is recommended. An initial retrospective evaluation in cancer cases and controls (Phase 1) is followed by a prospective evaluation of performance across the continuum of neoplastic lesions (Phase 2). Phase 3 follows the demonstration of adequate accuracy in these 2 prescreening phases and addresses programmatic outcomes at 1 screening round on an intention-to-screen basis. Phase 4 involves more comprehensive evaluation of ongoing screening over multiple rounds. Key information is provided from the following parameters: the test positivity rate in a screening population, the true-positive and false-positive rates, and the number needed to colonoscope to detect a target lesion. New screening tests can be evaluated efficiently by this stepwise comparative approach. © 2016 The Authors. Cancer published by Wiley Periodicals, Inc. on behalf of American Cancer Society.

  11. Study of Lamb Waves for Non-Destructive Testing Behind Screens

    NASA Astrophysics Data System (ADS)

    Kauffmann, P.; Ploix, M.-A.; Chaix, J.-F.; Gueudré, C.; Corneloup, G.; Baqué, F. AF(; )

    2018-01-01

    The inspection and control of sodium-cooled fast reactors (SFR) is a major issue for the nuclear industry. Ultrasonic solutions are under study because of the opacity of liquid sodium. In this paper, the use of leaky Lamb waves is considered for non-destructive testing (NDT) on parallel and immersed structures assimilated as plates. The first phase of our approach involved studying the propagation properties of leaky Lamb waves. Equations that model the propagation of Lamb waves in an immersed plate were solved numerically. The phase velocity can be experimentally measured using a two dimensional Fourier transform. The group velocity can be experimentally measured using a short-time Fourier transform technique. Attenuation of leaky Lamb waves is mostly due to the re-emission of energy into the surrounding fluid, and it can be measured by these two techniques.

  12. Discovery and ramifications of incidental Magnéli phase generation and release from industrial coal-burning.

    PubMed

    Yang, Yi; Chen, Bo; Hower, James; Schindler, Michael; Winkler, Christopher; Brandt, Jessica; Di Giulio, Richard; Ge, Jianping; Liu, Min; Fu, Yuhao; Zhang, Lijun; Chen, Yuru; Priya, Shashank; Hochella, Michael F

    2017-08-08

    Coal, as one of the most economic and abundant energy sources, remains the leading fuel for producing electricity worldwide. Yet, burning coal produces more global warming CO 2 relative to all other fossil fuels, and it is a major contributor to atmospheric particulate matter known to have a deleterious respiratory and cardiovascular impact in humans, especially in China and India. Here we have discovered that burning coal also produces large quantities of otherwise rare Magnéli phases (Ti x O 2x-1 with 4 ≤ x ≤ 9) from TiO 2 minerals naturally present in coal. This provides a new tracer for tracking solid-state emissions worldwide from industrial coal-burning. In its first toxicity testing, we have also shown that nanoscale Magnéli phases have potential toxicity pathways that are not photoactive like TiO 2 phases, but instead seem to be biologically active without photostimulation. In the future, these phases should be thoroughly tested for their toxicity in the human lung.Solid-state emissions from coal burning remain an environmental concern. Here, the authors have found that TiO2 minerals present in coal are converted into titanium suboxides during burning, and initial biotoxicity screening suggests that further testing is needed to look into human lung consequences.

  13. Optical probing of quantum Hall effect of composite fermions and of the liquid-insulator transition

    NASA Astrophysics Data System (ADS)

    Rossella, F.; Bellani, V.; Dionigi, F.; Amado, M.; Diez, E.; Kowalik, K.; Biasiol, G.; Sorba, L.

    2011-12-01

    In the photoluminescence spectra of a two-dimensional electron gas in the fractional quantum Hall regime we observe the states at filling factors ν = 4/5, 5/7, 4/11 and 3/8 as clear minima in the intensity or area emission peak. The first three states are described as interacting composite fermions in fractional quantum Hall regime. The minimum in the intensity at ν = 3/8, which is not explained within this picture, can be an evidence of a suppression of the screening of the Coulomb interaction among the effective quasi-particles involved in this intriguing state. The magnetic field energy dispersion at very low temperatures is also discussed. At low field the emission follows a Landau dispersion with a screened magneto-Coulomb contribution. At intermediate fields the hidden symmetry manifests. At high field above ν = 1/3 the electrons correlate into an insulating phase, and the optical emission behaviour at the liquid-insulator transition is coherent with a charge ordering driven by Coulomb correlations.

  14. Acoustic Reflex Testing in Neonatal Hearing Screening and Subsequent Audiological Evaluation.

    PubMed

    Jacob-Corteletti, Lilian Cássia Bórnia; Araújo, Eliene Silva; Duarte, Josilene Luciene; Zucki, Fernanda; Alvarenga, Kátia de Freitas

    2018-06-18

    The aims of the study were to examine the acoustic reflex screening and threshold in healthy neonates and those at risk of hearing loss and to determine the effect of birth weight and gestational age on acoustic stapedial reflex (ASR). We assessed 18 healthy neonates (Group I) and 16 with at least 1 risk factor for hearing loss (Group II); all of them passed the transient evoked otoacoustic emission test that assessed neonatal hearing. The test battery included an acoustic reflex screening with activators of 0.5, 1, 2, and 4 kHz and broadband noise and an acoustic reflex threshold test with all of them, except for the broadband noise activator. In the evaluated neonates, the main risk factors were the gestational age at birth and a low birth weight; hence, these were further analyzed. The lower the gestational age at birth and birth weight, the less likely that an acoustic reflex would be elicited by pure-tone activators. This effect was significant at the frequencies of 0.5, 1, and 2 kHz for gestational age at birth and at the frequencies of 1 and 2 kHz for birth weight. When the broadband noise stimulus was used, a response was elicited in all neonates in both groups. When the pure-tone stimulus was used, the Group II showed the highest acoustic reflex thresholds and the highest percentage of cases with an absent ASR. The ASR threshold varied from 50 to 100 dB HL in both groups. Group II presented higher mean ASR thresholds than Group I, this difference being significant at frequencies of 1, 2, and 4 kHz. Birth weight and gestational age at birth were related to the elicitation of the acoustic reflex. Neonates with these risk factors for hearing impairment were less likely to exhibit the acoustic reflex and had higher thresholds.

  15. 42 CFR 410.17 - Cardiovascular disease screening tests.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 2 2011-10-01 2011-10-01 false Cardiovascular disease screening tests. 410.17... § 410.17 Cardiovascular disease screening tests. (a) Definition. For purposes of this subpart, the... Part B covers cardiovascular disease screening tests when ordered by the physician who is treating the...

  16. 42 CFR 410.17 - Cardiovascular disease screening tests.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 2 2012-10-01 2012-10-01 false Cardiovascular disease screening tests. 410.17... § 410.17 Cardiovascular disease screening tests. (a) Definition. For purposes of this subpart, the... Part B covers cardiovascular disease screening tests when ordered by the physician who is treating the...

  17. 42 CFR 410.17 - Cardiovascular disease screening tests.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 2 2013-10-01 2013-10-01 false Cardiovascular disease screening tests. 410.17... § 410.17 Cardiovascular disease screening tests. (a) Definition. For purposes of this subpart, the... Part B covers cardiovascular disease screening tests when ordered by the physician who is treating the...

  18. 42 CFR 410.17 - Cardiovascular disease screening tests.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 2 2014-10-01 2014-10-01 false Cardiovascular disease screening tests. 410.17... § 410.17 Cardiovascular disease screening tests. (a) Definition. For purposes of this subpart, the... Part B covers cardiovascular disease screening tests when ordered by the physician who is treating the...

  19. 42 CFR 410.17 - Cardiovascular disease screening tests.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 2 2010-10-01 2010-10-01 false Cardiovascular disease screening tests. 410.17... § 410.17 Cardiovascular disease screening tests. (a) Definition. For purposes of this subpart, the... Part B covers cardiovascular disease screening tests when ordered by the physician who is treating the...

  20. Uptake of prenatal diagnostic testing and the effectiveness of prenatal screening for Down syndrome.

    PubMed

    Jaques, Alice M; Collins, Veronica R; Muggli, Evelyne E; Amor, David J; Francis, Ivan; Sheffield, Leslie J; Halliday, Jane L

    2010-06-01

    To map prenatal screening and diagnostic testing pathways in Victorian pregnant women during 2003 to 2004; measure the impact of prenatal diagnostic testing uptake on the effectiveness of prenatal screening for Down syndrome; and assess factors influencing uptake of diagnostic testing following screening. State-wide data collections of prenatal screening and diagnostic tests were linked to all Victorian births and pregnancy terminations for birth defects. Overall, 52% of women had a prenatal test (65 692/126 305); screening (44.9%), diagnostic testing (3.9%), or both (3.2%). Uptake of diagnostic testing was 71.4% (2390/3349) after an increased risk screen result, and 2.5% (1381/54 286) after a low risk result. Variation in uptake of diagnostic testing reduced the effectiveness of the screening program by 11.2%: from 87.4% (sensitivity - 125/143) to 76.2% (prenatal diagnoses of Down syndrome - 109/143). In both the increased and low risk groups, uptake was influenced by absolute numerical risk, as well as by the change in numerical risk from a priori risk. This comprehensive follow-up demonstrates clearly that numerical risk is being used to aid in decision making about confirmatory diagnostic testing. Collectively, these fundamental individual decisions will impact on the overall effectiveness of screening programmes for Down syndrome.

  1. Early Adoption of a Multitarget Stool DNA Test for Colorectal Cancer Screening.

    PubMed

    Finney Rutten, Lila J; Jacobson, Robert M; Wilson, Patrick M; Jacobson, Debra J; Fan, Chun; Kisiel, John B; Sweetser, Seth; Tulledge-Scheitel, Sidna M; St Sauver, Jennifer L

    2017-05-01

    To characterize early adoption of a novel multitarget stool DNA (MT-sDNA) screening test for colorectal cancer (CRC) screening and to test the hypothesis that adoption differs by demographic characteristics and prior CRC screening behavior and proceeds predictably over time. We used the Rochester Epidemiology Project research infrastructure to assess the use of the MT-sDNA screening test in adults aged 50 to 75 years living in Olmsted County, Minnesota, in 2014 and identified 27,147 individuals eligible or due for screening colonoscopy from November 1, 2014, through November 30, 2015. We used electronic Current Procedure Terminology and Health Care Common Procedure codes to evaluate early adoption of the MT-sDNA screening test in this population and to test whether early adoption varies by age, sex, race, and prior CRC screening behavior. Overall, 2193 (8.1%) and 974 (3.6%) individuals were screened by colonoscopy and MT-sDNA, respectively. Age, sex, race, and prior CRC screening behavior were significantly and independently associated with MT-sDNA screening use compared with colonoscopy use after adjustment for all other variables (P<.05 for all). The rates of adoption of MT-sDNA screening increased over time and were highest in those aged 50 to 54 years, women, whites, and those who had a history of screening. The use of the MT-sDNA screening test varied predictably by insurance coverage. The rates of colonoscopy decreased over time, whereas overall CRC screening rates remained steady. The results of the present study are generally consistent with predictions derived from prior research and the diffusion of innovation framework, pointing to increasing use of the new screening test over time and early adoption by younger patients, women, whites, and those with prior CRC screening. Copyright © 2017 Mayo Foundation for Medical Education and Research. Published by Elsevier Inc. All rights reserved.

  2. Neuroblastoma Screening

    MedlinePlus

    ... including physical and emotional problems. False-negative test results can occur. Screening test results may appear to ... even if there are symptoms. False-positive test results can occur. Screening test results may appear to ...

  3. Acoustic emission studies of posterior stabilized and cruciate retaining knee arthroplasties.

    PubMed

    Schwarzkopf, Ran; Kummer, Frederick J; Jaffe, William L

    2011-09-01

    Different acoustic frequencies have been used to diagnose progression of osteoarthritis, gross pathology, and wear in knee prostheses. It is possible that detailed analysis of higher frequencies could detect and quantify the smaller geometric changes (asperities) that develop in articular prosthetic wear. In this study we evaluated the feasibility of using ultrasonic emission to determine total knee arthroplasty (TKA) type and time from implantation using a simple, handheld measurement system. We examined the ultrasound emission generated by similar designs of posterior stabilized (PS) and cruciate retaining (CR) total knee prostheses and native knees of 58 patients and 10 controls. The subjects were asked to sit, rise, sit again, and take five steps while recording the acoustic data from both knees. Acoustic emission analysis examined frequency distributions and power spectrums of the recorded signals, and their relations to prosthesis type and time from implantation. We screened 44 CR and 48 PS TKAs, as well as 24 native knees. Analysis of this data suggested a possibility of differentiating between type of implants, and a relation to time since implantation. Our data suggest that we might be able to assess the status and time from implantation of a TKA by acoustic emission signals. Further in vitro analysis of the relationship of wear to ultrasonic emission data are needed for accurate quantification of arthroplasty wear. A simple, in-office screening tool for TKA patients could indicate which patients require closer follow-up and monitoring due to risk of potential problems.

  4. Early Adoption of a Multi-target Stool DNA Test for Colorectal Cancer Screening

    PubMed Central

    Finney Rutten, Lila J.; Jacobson, Robert M.; Wilson, Patrick M.; Jacobson, Debra J.; Fan, Chun; Kisiel, John B.; Sweetser, Seth R.; Tulledge-Scheitel, Sidna M.; St. Sauver, Jennifer L.

    2017-01-01

    Objective To characterize early adoption of a novelmulti-target stool deoxyribonucleic acid (MTsDNA) screening test for colorectal cancer (CRC) and test the hypothesis that adoption differs by demographic characteristics, prior CRC screening behavior, and proceeds predictably over time. Patients and Methods We used the Rochester Epidemiology Project infrastructure to assess MTsDNA screening test use among adults aged 50–75 years, and identified 27,147 individuals eligible/due for screening colonoscopy from November 1, 2014 through November 30, 2015, and living in Olmsted County, Minnesota in2014. We used electronic Current Procedure Terminology and Health Care Common Procedure codes to evaluate early adoption of MTsDNA screening test in this population and to test whether early adoption varies by age, sex, race, and prior screening behavior. Results Overall, 2,193 (8.1%) and 974 (3.6%) of individuals were screened by colonoscopy and MT-sDNA, respectively. Age, sex, race, and prior screening were significantly and independently associated with MT-sDNA screening use compared to colonoscopy use after adjustment for all other variables. Rates of adoption of MTsDNA screening increased over time and were highest among those aged 50–54 years, females, whites, and had a prior history of screening. MT-sDNA screening use varied predictably by insurance coverage. Rates of colonoscopy decreased over time, while overall CRC screening rates remained steady. Conclusion Our results are generally consistent with predictions derived from prior research and Diffusion of Innovation framework, pointing to increasing use of the new screening test over time, and early adoption by younger patients, females, whites and those with prior CRC screening. PMID:28473037

  5. Potential Biases Introduced by Conflating Screening and Diagnostic Testing in Colorectal Cancer Screening Surveillance

    PubMed Central

    Becker, Elizabeth A.; Griffith, Derek M.; West, Brady T.; Janz, Nancy K.; Resnicow, Ken; Morris, Arden M.

    2015-01-01

    Background Screening and post-symptomatic diagnostic testing are often conflated in cancer screening surveillance research. We examined the error in estimated colorectal cancer (CRC) screening prevalence due to the conflation of screening and diagnostic testing. Methods Using data from the 2008 National Health Interview Survey, we compared weighted prevalence estimates of the use of all testing (screening and diagnostic) and screening in at-risk adults, and calculated the overestimation of screening prevalence across socio-demographic groups. Results The population screening prevalence was overestimated by 23.3%, and the level of overestimation varied widely across socio-demographic groups (median 22.6%, mean 24.8%). The highest levels of overestimation were in non-Hispanic White females (27.4%), adults ages 50–54 (32.0%), and those with the highest socioeconomic vulnerability (low educational attainment (31.3%), low poverty ratio (32.5%), no usual source of health care (54.4%) and not insured (51.6%)) (all p-values < 0.001). Conclusions When the impetus for testing was not included, CRC screening prevalence was overestimated, and patterns of overestimation often aligned with social and economic vulnerability. These results are of concern to researchers who utilize survey data from the Behavioral Risk Factor Surveillance System (BRFSS) to assess cancer screening behaviors, as it is currently not designed to distinguish diagnostic testing from screening. Impact Surveillance research in cancer screening that does not consider the impetus for testing risks measurement error of screening prevalence, impeding progress toward improving population health. Ultimately, in order to craft relevant screening benchmarks and interventions, we must look beyond ‘what’ and ‘when’ and include ‘why.’ PMID:26491056

  6. Scanned-probe field-emission studies of vertically aligned carbon nanofibers

    NASA Astrophysics Data System (ADS)

    Merkulov, Vladimir I.; Lowndes, Douglas H.; Baylor, Larry R.

    2001-02-01

    Field emission properties of dense and sparse "forests" of randomly placed, vertically aligned carbon nanofibers (VACNFs) were studied using a scanned probe with a small tip diameter of ˜1 μm. The probe was scanned in directions perpendicular and parallel to the sample plane, which allowed for measuring not only the emission turn-on field at fixed locations but also the emission site density over large surface areas. The results show that dense forests of VACNFs are not good field emitters as they require high extracting (turn-on) fields. This is attributed to the screening of the local electric field by the neighboring VACNFs. In contrast, sparse forests of VACNFs exhibit moderate-to-low turn-on fields as well as high emission site and current densities, and long emission lifetime, which makes them very promising for various field emission applications.

  7. Skin Cancer Screening

    MedlinePlus

    ... may have serious side effects . False-negative test results can occur. Screening test results may appear to ... even if there are symptoms. False-positive test results can occur. Screening test results may appear to ...

  8. Glucose screening tests during pregnancy

    MedlinePlus

    Oral glucose tolerance test - pregnancy; OGTT - pregnancy; Glucose challenge test - pregnancy; Gestational diabetes - glucose screening ... first step, you will have a glucose screening test: You DO NOT need to prepare or change ...

  9. Cognitive Screening Tests Versus Comprehensive Neuropsychological Test Batteries: A National Academy of Neuropsychology Education Paper†.

    PubMed

    Roebuck-Spencer, Tresa M; Glen, Tannahill; Puente, Antonio E; Denney, Robert L; Ruff, Ronald M; Hostetter, Gayle; Bianchini, Kevin J

    2017-06-01

    The American Medical Association Current Procedural Panel developed a new billing code making behavioral health screening a reimbursable healthcare service. The use of computerized testing as a means for cognitive screening and brief cognitive testing is increasing at a rapid rate. The purpose of this education paper is to provide information to clinicians, healthcare administrators, and policy developers about the purpose, strengths, and limitations of cognitive screening tests versus comprehensive neuropsychological evaluations. Screening tests are generally brief and narrow in scope, they can be administered during a routine clinical visit, and they can be helpful for identifying individuals in need of more comprehensive assessment. Some screening tests can also be helpful for monitoring treatment outcomes. Comprehensive neuropsychological assessments are multidimensional in nature and used for purposes such as identifying primary and secondary diagnoses, determining the nature  and severity of a person's cognitive difficulties, determining functional limitations, and planning treatment and rehabilitation. Cognitive screening tests are expected to play an increasingly important role in identifying individuals with cognitive impairment and in determining which individuals should be referred for further neuropsychological assessment. However, limitations of existing cognitive screening tests are present and cognitive screening tests should not be used as a replacement for comprehensive neuropsychological testing. © The Author 2017. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  10. Screening tests for aphasia in patients with stroke: a systematic review.

    PubMed

    El Hachioui, Hanane; Visch-Brink, Evy G; de Lau, Lonneke M L; van de Sandt-Koenderman, Mieke W M E; Nouwens, Femke; Koudstaal, Peter J; Dippel, Diederik W J

    2017-02-01

    Aphasia has a large impact on the quality of life and adds significantly to the costs of stroke care. Early recognition of aphasia in stroke patients is important for prognostication and well-timed treatment planning. We aimed to identify available screening tests for differentiating between aphasic and non-aphasic stroke patients, and to evaluate test accuracy, reliability, and feasibility. We searched PubMed, EMbase, Web of Science, and PsycINFO for published studies on screening tests aimed at assessing aphasia in stroke patients. The reference lists of the selected articles were scanned, and several experts were contacted to detect additional references. Of each screening test, we estimated the sensitivity, specificity, likelihood ratio of a positive test, likelihood ratio of a negative test, and diagnostic odds ratio (DOR), and rated the degree of bias of the validation method. We included ten studies evaluating eight screening tests. There was a large variation across studies regarding sample size, patient characteristics, and reference tests used for validation. Many papers failed to report on the consecutiveness of patient inclusion, time between aphasia onset and administration of the screening test, and blinding. Of the three studies that were rated as having an intermediate or low risk of bias, the DOR was highest for the Language Screening Test and ScreeLing. Several screening tools for aphasia in stroke are available, but many tests have not been verified properly. Methodologically sound validation studies of aphasia screening tests are needed to determine their usefulness in clinical practice.

  11. 42 CFR 410.37 - Colorectal cancer screening tests: Conditions for and limitations on coverage.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 2 2010-10-01 2010-10-01 false Colorectal cancer screening tests: Conditions for...) BENEFITS Medical and Other Health Services § 410.37 Colorectal cancer screening tests: Conditions for and...) Colorectal cancer screening tests means any of the following procedures furnished to an individual for the...

  12. 42 CFR 410.37 - Colorectal cancer screening tests: Conditions for and limitations on coverage.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 2 2011-10-01 2011-10-01 false Colorectal cancer screening tests: Conditions for...) BENEFITS Medical and Other Health Services § 410.37 Colorectal cancer screening tests: Conditions for and...) Colorectal cancer screening tests means any of the following procedures furnished to an individual for the...

  13. 42 CFR 410.37 - Colorectal cancer screening tests: Conditions for and limitations on coverage.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 2 2013-10-01 2013-10-01 false Colorectal cancer screening tests: Conditions for...) BENEFITS Medical and Other Health Services § 410.37 Colorectal cancer screening tests: Conditions for and...) Colorectal cancer screening tests means any of the following procedures furnished to an individual for the...

  14. 42 CFR 410.37 - Colorectal cancer screening tests: Conditions for and limitations on coverage.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 2 2012-10-01 2012-10-01 false Colorectal cancer screening tests: Conditions for...) BENEFITS Medical and Other Health Services § 410.37 Colorectal cancer screening tests: Conditions for and...) Colorectal cancer screening tests means any of the following procedures furnished to an individual for the...

  15. 42 CFR 410.37 - Colorectal cancer screening tests: Conditions for and limitations on coverage.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 2 2014-10-01 2014-10-01 false Colorectal cancer screening tests: Conditions for...) BENEFITS Medical and Other Health Services § 410.37 Colorectal cancer screening tests: Conditions for and...) Colorectal cancer screening tests means any of the following procedures furnished to an individual for the...

  16. Pap Testing Stages of Adoption among Cambodian Immigrants

    PubMed Central

    Taylor, Victoria M.; Jackson, J. Carey; Yasui, Yutaka; Schwartz, Stephen M.; Kuniyuki, Alan; Fischer, Meredith; Tu, Shin-Ping

    2006-01-01

    Purpose We examined levels of Pap testing and factors associated with screening participation among Cambodian refugees. Methods A community-based, in-person survey was conducted in Seattle during late 1997 and early 1998. Interviews were completed by 413 women; the estimated response rate was 73%. We classified respondents into four Pap testing stages of adoption: precontemplation/contemplation (never screened), relapse (ever screened but did not plan to be screened in the future), action (ever screened and planned to be screened in the future), and maintenance (recently screened and planned to be screened in the future). Bivariate and multivariate techniques were used to examine various factors. Findings About one-quarter (24%) of the respondents has never been screened, and a further 22% had been screened but did not plan to obtain Pap tests in the future. Fifteen percent were in the action stage and 39% were in the maintenance stage. The following factors were independently associated with cervical cancer screening stages: previous physician recommendation; younger age; beliefs about Pap testing for post-menopausal women, screening for sexually inactive women, and regular checkups; provider ethnicity; prenatal care in the US; and problems finding interpreters. Conclusions Our findings confirm low Pap testing rates among Cambodian immigrants, and suggest that targeted interventions should be multifaceted. PMID:11567513

  17. 40 CFR 799.9355 - TSCA reproduction/developmental toxicity screening test.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... toxicity screening test. 799.9355 Section 799.9355 Protection of Environment ENVIRONMENTAL PROTECTION... AND MIXTURE TESTING REQUIREMENTS Health Effects Test Guidelines § 799.9355 TSCA reproduction/developmental toxicity screening test. (a) Scope—(1) Applicability. This section is intended to meet testing...

  18. 40 CFR 799.9355 - TSCA reproduction/developmental toxicity screening test.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... toxicity screening test. 799.9355 Section 799.9355 Protection of Environment ENVIRONMENTAL PROTECTION... AND MIXTURE TESTING REQUIREMENTS Health Effects Test Guidelines § 799.9355 TSCA reproduction/developmental toxicity screening test. (a) Scope—(1) Applicability. This section is intended to meet testing...

  19. Ultraweak photon emission and proteomics analyses in soybean under abiotic stress.

    PubMed

    Komatsu, Setsuko; Kamal, Abu Hena Mostafa; Makino, Takahiro; Hossain, Zahed

    2014-07-01

    Biophotons are ultraweak photon emissions that are closely related to various biological activities and processes. In mammals, biophoton emissions originate from oxidative bursts in immunocytes during immunological responses. Biophotons emitted from plant organs provide novel information about the physiological state of plant under in vivo condition. In this review, the principles and recent advances in the measurement of biophoton emissions in plants are described. Furthermore, examples of biophoton emission and proteomics in soybean under abiotic stress are reviewed and discussed. Finally, this review suggests that the application of proteomics should provide a better interpretation of plant response to biophoton emission and allow the identification of genes that will allow the screening of crops able to produce maximal yields, even in stressful environments. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. HPV primary cervical screening in England: Women's awareness and attitudes.

    PubMed

    Patel, Hersha; Moss, Esther L; Sherman, Susan M

    2018-03-09

    Primary human papillomavirus (HPV) cervical screening is due to be implemented in England within the next 2 years; however, the acceptability of HPV testing as the primary screening test is unclear. This study explores women's awareness and attitudes toward HPV testing/screening. Qualitative interviews (semistructured and focus group) were conducted with 46 women (aged 25-65 years) from community and secondary care settings. Data were analyzed by using the inductive-framework method. Women were unaware that cervical screening currently includes HPV testing and lacked HPV-related knowledge. Emotions of shock, fear, and anxiety were reported upon receiving a positive HPV result. For women in long-term relationships, the realization that HPV is a sexually transmitted infection was seen as a barrier to primary HPV testing. Knowledge that HPV testing is a screening test to prevent cervical cancer did not change their attitudes. Women debated the need for continued screening following a negative result. Women feared judgment by the community if they participated with primary HPV screening because they were being tested for a sexually transmitted infection, with the possible attendant perception that they had adopted a high-risk lifestyle in comparison to nonattenders. The acceptability of HPV testing may be a limiting factor in encouraging participation with screening in the future. Copyright © 2018 John Wiley & Sons, Ltd.

  1. Evaluation of 25-Percent ATJ Fuel Blends in the John Deere 4045HF 280 Engine

    DTIC Science & Technology

    2014-08-01

    25% ATJ Blend ........ 26 Figure 16 . THC Emissions, Pre-Test, Ambient Temperature ...................................................... 28 Figure...17 . THC Emissions, Pre-Test, Desert Temperature ......................................................... 28 Figure 18 . NOx Emissions, Pre-Test...Emissions, Pre-Test, Desert Temperature (Scaled) ............................................. 32 Figure 23 . THC Emissions, Post-Test, Ambient

  2. Risks of Skin Cancer Screening

    MedlinePlus

    ... may have serious side effects . False-negative test results can occur. Screening test results may appear to ... even if there are symptoms. False-positive test results can occur. Screening test results may appear to ...

  3. N2O emission from plant surfaces - light stimulated and a global phenomenon.

    NASA Astrophysics Data System (ADS)

    Mikkelsen, Teis; Bruhn, Dan; Ambus, Per

    2017-04-01

    Nitrous oxide (N2O) is an important long-lived greenhouse gas and precursor of stratospheric ozone depleting mono-nitrogen oxides. The atmospheric concentration of N2O is persistently increasing; however, large uncertainties are associated with the distinct source strengths. Here we investigate for the first time N2O emission from terrestrial vegetation in response to natural solar ultra violet radiation. We conducted field site measurements to investigate N2O atmosphere exchange from grass vegetation exposed to solar irradiance with and without UV-screening. Further laboratory tests were conducted with a range of species to study the controls and possible loci of UV-induced N2O emission from plants. Plants released N2O in response to natural sunlight at rates of c. 20-50 nmol m-2 h-1, mostly due to the UV component. The emission rate is temperature dependent with a rather high activation energy indicative for an abiotic process. The prevailing zone for the N2O formation appears to be at the very surface of leaves. However, only c. 26% of the UV-induced N2O appears to originate from plant-N. Further, the process is dependent on atmospheric oxygen concentration. Our work demonstrates that ecosystem emission of the important greenhouse gas, N2O, may be up to c. 30% higher than hitherto assumed. Literature: Mikkelsen TN, Bruhn D & Ambus P. (2016). Solar UV Irradiation-Induced Production of Greenhouse Gases from Plant Surfaces: From Leaf to Earth. Progress in Botany, DOI 10.1007/124_2016_10. Bruhn D, Albert KR, Mikkelsen TN & Ambus P. (2014). UV-induced N2O emission from plants. Atmospheric Environment 99, 206-214.

  4. Immunomagnetic Nano-Screening Chip for Circulating Tumor Cells Detection in Blood

    NASA Astrophysics Data System (ADS)

    Horton, A. P.; Lane, N.; Tam, J.; Sokolov, K.; Garner, H. R.; Uhr, J. W.; Zhang, X. J.

    2010-03-01

    We present a novel method towards diagnose cancer at an early stage via a blood test. Early diagnosis is high on the future agenda of oncologists because of significant evidence that it will result in a higher cure rate. Capture of circulating tumor cells (CTCs) which are known to escape from carcinomas at an early stage offers such an opportunity. We design, fabricate and optimize the nanomagnetic-screening chip that captures the CTCs in microfluid, and further integrate the nano-chip with the new multispectral imaging system so that it can quantify different tumor markers and automate the entire instrument. Specifically, hybrid plasmonic (Fe2O3-core Au shell) nanoparticles, conjugated a collection of antibodies especially chosen to target breast cancer CTCs, with high magnetic susceptibility will be used for effective immunomagnetic CTC isolation. Greatly increased sensitivity over previous attempts is demonstrated by decreasing the length scale for interactions between the magnetic-nanoparticle-tagged CTCs and the isolative magnetic field, while increasing the effective cross-sectional area over which this interaction takes place. The screening chip is integrated with a novel hyperspectral microscopic imaging (HMI) platform capable of recording the entire emission spectra in a single pass evaluation. The combined system will precisely quantify up to 10 tumor markers on CTCs.

  5. 21 CFR 1270.21 - Determination of donor suitability for human tissue intended for transplantation.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 2 (e.g., FDA licensed screening test for anti-HIV-2); (3) Hepatitis B (e.g., FDA licensed screening test for HBsAg); and (4) Hepatitis C (e.g., FDA licensed screening test for anti-HCV). (b) In the case... been tested and found negative using FDA licensed screening tests for HIV-1, HIV-2, hepatitis B, and...

  6. 40 CFR 1060.510 - How do I test EPA Low-Emission Fuel Lines for permeation emissions?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 33 2011-07-01 2011-07-01 false How do I test EPA Low-Emission Fuel... NONROAD AND STATIONARY EQUIPMENT Test Procedures § 1060.510 How do I test EPA Low-Emission Fuel Lines for permeation emissions? For EPA Low-Emission Fuel Lines, measure emissions according to SAE J2260, which is...

  7. 40 CFR 1060.510 - How do I test EPA Low-Emission Fuel Lines for permeation emissions?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 34 2012-07-01 2012-07-01 false How do I test EPA Low-Emission Fuel... NONROAD AND STATIONARY EQUIPMENT Test Procedures § 1060.510 How do I test EPA Low-Emission Fuel Lines for permeation emissions? For EPA Low-Emission Fuel Lines, measure emissions according to SAE J2260, which is...

  8. 40 CFR 1060.510 - How do I test EPA Low-Emission Fuel Lines for permeation emissions?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 34 2013-07-01 2013-07-01 false How do I test EPA Low-Emission Fuel... NONROAD AND STATIONARY EQUIPMENT Test Procedures § 1060.510 How do I test EPA Low-Emission Fuel Lines for permeation emissions? For EPA Low-Emission Fuel Lines, measure emissions according to SAE J2260, which is...

  9. 40 CFR 1060.510 - How do I test EPA Low-Emission Fuel Lines for permeation emissions?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 33 2014-07-01 2014-07-01 false How do I test EPA Low-Emission Fuel... NONROAD AND STATIONARY EQUIPMENT Test Procedures § 1060.510 How do I test EPA Low-Emission Fuel Lines for permeation emissions? For EPA Low-Emission Fuel Lines, measure emissions according to SAE J2260, which is...

  10. 40 CFR 1060.510 - How do I test EPA Low-Emission Fuel Lines for permeation emissions?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 32 2010-07-01 2010-07-01 false How do I test EPA Low-Emission Fuel... NONROAD AND STATIONARY EQUIPMENT Test Procedures § 1060.510 How do I test EPA Low-Emission Fuel Lines for permeation emissions? For EPA Low-Emission Fuel Lines, measure emissions according to SAE J2260, which is...

  11. A low-cost method for visible fluorescence imaging.

    PubMed

    Tarver, Crissy L; Pusey, Marc

    2017-12-01

    A wide variety of crystallization solutions are screened to establish conditions that promote the growth of a diffraction-quality crystal. Screening these conditions requires the assessment of many crystallization plates for the presence of crystals. Automated systems for screening and imaging are very expensive. A simple approach to imaging trace fluorescently labeled protein crystals in crystallization plates has been devised, and can be implemented at a cost as low as $50. The proteins β-lactoglobulin B, trypsin and purified concanavalin A (ConA) were trace fluorescently labeled using three different fluorescent probes: Cascade Yellow (CY), Carboxyrhodamine 6G (CR) and Pacific Blue (PB). A crystallization screening plate was set up using β-lactoglobulin B labeled with CR, trypsin labeled with CY, ConA labeled with each probe, and a mixture consisting of 50% PB-labeled ConA and 50% CR-labeled ConA. The wells of these plates were imaged using a commercially available macro-imaging lens attachment for smart devices that have a camera. Several types of macro lens attachments were tested with smartphones and tablets. Images with the highest quality were obtained with an iPhone 6S and an AUKEY Ora 10× macro lens. Depending upon the fluorescent probe employed and its Stokes shift, a light-emitting diode or a laser diode was used for excitation. An emission filter was used for the imaging of protein crystals labeled with CR and crystals with two-color fluorescence. This approach can also be used with microscopy systems commonly used to observe crystallization plates.

  12. The determination of aluminum, copper, iron, and lead in glycol formulations by atomic absorption spectroscopy

    NASA Technical Reports Server (NTRS)

    1977-01-01

    Initial screening tests and the results obtained in developing procedures to determine Al, Cu, Fe, and Pb in glycol formulations are described. Atomic absorption completion was selected for Cu, Fe and Pb, and after comparison with emission spectroscopy, was selected for Al also. Before completion, carbon, iron, and lead are extracted with diethyl dithio carbamate (DDC) into methyl isobutyl ketone (MIBK). Aluminum was also extracted into MIBK using 8-hydroxyquinoline as a chelating agent. As little as 0.02 mg/l carbon and 0.06 mg/l lead or iron may be determined in glycol formulations. As little as 0.3 mg/l aluminum may be determined.

  13. Impact of state-specific Medicaid reimbursement and eligibility policies on receipt of cancer screening.

    PubMed

    Halpern, Michael T; Romaire, Melissa A; Haber, Susan G; Tangka, Florence K; Sabatino, Susan A; Howard, David H

    2014-10-01

    Although state Medicaid programs cover cancer screening, Medicaid beneficiaries are less likely to be screened for cancer and are more likely to present with tumors of an advanced stage than are those with other insurance. The current study was performed to determine whether state Medicaid eligibility and reimbursement policies affect the receipt of breast, cervical, and colon cancer screening among Medicaid beneficiaries. Cross-sectional regression analyses of 2007 Medicaid data from 46 states and the District of Columbia were performed to examine associations between state-specific Medicaid reimbursement/eligibility policies and receipt of cancer screening. The study sample included individuals aged 21 years to 64 years who were enrolled in fee-for-service Medicaid for at least 4 months. Subsamples eligible for each screening test were: Papanicolaou test among 2,136,511 patients, mammography among 792,470 patients, colonoscopy among 769,729 patients, and fecal occult blood test among 753,868 patients. State-specific Medicaid variables included median screening test reimbursement, income/financial asset eligibility requirements, physician copayments, and frequency of eligibility renewal. Increases in screening test reimbursement demonstrated mixed associations (positive and negative) with the likelihood of receiving screening tests among Medicaid beneficiaries. In contrast, increased reimbursements for office visits were found to be positively associated with the odds of receiving all screening tests examined, including colonoscopy (odds ratio [OR], 1.07; 95% confidence interval [95% CI], 1.06-1.08), fecal occult blood test (OR, 1.09; 95% CI, 1.08-1.10), Papanicolaou test (OR, 1.02; 95% CI, 1.02-1.03), and mammography (OR, 1.02; 95% CI, 1.02-1.03). Effects of other state-specific Medicaid policies varied across the screening tests examined. Increased reimbursement for office visits was consistently associated with an increased likelihood of being screened for cancer, and may be an important policy tool for increasing screening among this vulnerable population. © 2014 American Cancer Society.

  14. Screening for Syphilis: Updated Evidence Report and Systematic Review for the US Preventive Services Task Force.

    PubMed

    Cantor, Amy G; Pappas, Miranda; Daeges, Monica; Nelson, Heidi D

    2016-06-07

    Screening for syphilis infection is currently recommended for high-risk individuals, including those with previous syphilis infection, an infected sexual partner, HIV infection, or more than 4 sex partners in the preceding year. To update a 2004 systematic review of studies of syphilis screening effectiveness, test accuracy, and screening harms in nonpregnant adults and adolescents. Cochrane Central Register of Controlled Trials and Cochrane Database of Systematic Reviews through October 2015 and Ovid MEDLINE (January 2004 to October 2015), with updated search through March 2016. English-language trials and observational studies of screening effectiveness, test accuracy, and screening harms in nonpregnant adults and adolescents. One investigator abstracted data, a second checked data for accuracy, and 2 investigators independently assessed study quality using predefined criteria. Transmission of disease, including HIV; complications of syphilis; diagnostic accuracy; and harms of screening. No evidence was identified regarding the effectiveness of screening on clinical outcomes or the effectiveness of risk assessment instruments; the harms of screening; or the effectiveness of screening in average-risk, nonpregnant adolescents or adults or high-risk individuals other than men who have sex with men (MSM) or men who are HIV positive. Four non-US studies indicated higher rates of syphilis detection with screening every 3 months vs 6 or 12 months for early syphilis in HIV-positive men or MSM. For example, there was an increased proportion of asymptomatic, higher-risk MSM in Australia (n = 6789 consultations) receiving a diagnosis of early syphilis when tested every 3 months vs annually (53% vs 16%, P = .001), but no difference among low-risk MSM. Treponemal and nontreponemal tests were accurate in asymptomatic individuals (sensitivity >85%, specificity >91%) in 3 studies but required confirmatory testing. Reverse sequence testing with an initial automated treponemal test yielded more false reactive test results than with rapid plasma reagin in 2 studies, one with a low-prevalence US population (0.6% vs 0.0%, P = .03) and another in a higher-prevalence Canadian population (0.26% vs 0.13%). Screening HIV-positive men or MSM for syphilis every 3 months is associated with improved syphilis detection. Treponemal or nontreponemal tests are accurate screening tests but require confirmation. Research is needed on the effect of screening on clinical outcomes; effective screening strategies, including reverse sequence screening, in various patient populations; and harms of screening.

  15. Screening for coronary heart disease risk factors in retail pharmacies in Sheffield, 1992.

    PubMed Central

    Allison, C; Page, H; George, S

    1994-01-01

    OBJECTIVE--To investigate the current and likely future provision of screening services for risk factors for coronary heart disease in retail pharmacies in Sheffield. DESIGN--This was a questionnaire survey asking about screening tests currently offered, price charged per test, likely future provision of screening tests, the action respondents would take upon finding an abnormal test result, whether the pharmacy was owner-run, franchised, or part of a commercial chain, and inviting open comments from respondents. SETTING--All retail pharmacy premises on the Sheffield Family Health Services Authority list. RESULTS--Seventy seven responses were obtained to 102 questionnaires distributed. Only nine of these currently offered any screening test other than pregnancy testing, although 37 indicated that they might offer tests in the future. Thirty nine were not offering screening and had no plans to do so. Pharmacies offering or likely to offer screening tests were mainly owner-run. All pharmacists who replied to the question asking about their action upon finding abnormal result (33) reported that they would advise the patient to see a doctor. The most frequent comments made by pharmacists were about the commercial viability of screening in pharmacies and the lack of space available to ensure patient privacy and confidentiality during screening. CONCLUSIONS--Screening in retail pharmacies would probably be a commercial failure unless doctors were able to contract for screening services from pharmacies. Evidence from this study and others, however, leads us to question the desirability of this option. PMID:8189175

  16. Hydroxychloroquine screening practice patterns within a large multispecialty ophthalmic practice.

    PubMed

    Au, Adrian; Parikh, Vishal; Modi, Yasha S; Ehlers, Justis P; Schachat, Andrew P; Singh, Rishi P

    2015-09-01

    To determine provider compliance with hydroxychloroquine screening following the revised recommendations published in 2011 by the American Academy of Ophthalmology. Evaluation of adherence to a screening protocol. Subjects were identified with hydroxychloroquine as a medication by electronic query at a large multispecialty ophthalmic practice. Patients were excluded if patients: (1) were screened by an outside physician; (2) lacked recorded height, weight, start date, or dosing; or (3) took hydroxychloroquine for malaria prophylaxis. Screening tests were stratified by ophthalmic subspecialty. Guidelines define proper screening as 1 subjective test-Humphrey visual field (HVF), and 1 objective test-spectral-domain optical coherence tomography (SD OCT), fundus autofluorescence (FAF), or multifocal electroretinography (mfERG). Adherence to guidelines was determined by categorizing practices as: (1) "appropriate"-consistent with guidelines; (2) "underscreened"-insufficient testing; or (3) "inappropriate"-no testing. The study comprised 756 patients with a mean age of 56 years undergoing 1294 screening visits. Twenty-one patients received initial screenings outside the institution. Most common screening tests employed included SD OCT (56.6%), 10-2 HVF (55.0%), and Amsler grid (40.0%). Of the 735 initial screenings, 341 (46.4%) were appropriately screened, 204 (27.8%) underscreened, and 190 (25.9%) inappropriately screened. Of those who presented solely for screening (560), 307 (54.8%) were appropriately screened, 144 (25.7%) underscreened, and 109 (19.5%) inappropriately screened. Of patients presenting for hydroxychloroquine screening, 54.8% of patients received appropriate evaluation, indicating lack of adherence to guidelines. Overall, SD OCT and 10-2 HVF were the preferred screening modalities, with FAF and mfERG less frequently ordered. Copyright © 2015 Elsevier Inc. All rights reserved.

  17. 42 CFR 410.39 - Prostate cancer screening tests: Conditions for and limitations on coverage.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 2 2010-10-01 2010-10-01 false Prostate cancer screening tests: Conditions for and... Medical and Other Health Services § 410.39 Prostate cancer screening tests: Conditions for and limitations... cancer screening tests means any of the following procedures furnished to an individual for the purpose...

  18. 21 CFR 862.1055 - Newborn screening test system for amino acids, free carnitine, and acylcarnitines using tandem...

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Newborn screening test system for amino acids... screening test system for amino acids, free carnitine, and acylcarnitines using tandem mass spectrometry. (a) Identification. A newborn screening test system for amino acids, free carnitine, and acylcarnitines using tandem...

  19. 21 CFR 862.1055 - Newborn screening test system for amino acids, free carnitine, and acylcarnitines using tandem...

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Newborn screening test system for amino acids... screening test system for amino acids, free carnitine, and acylcarnitines using tandem mass spectrometry. (a) Identification. A newborn screening test system for amino acids, free carnitine, and acylcarnitines using tandem...

  20. 42 CFR 410.39 - Prostate cancer screening tests: Conditions for and limitations on coverage.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 2 2011-10-01 2011-10-01 false Prostate cancer screening tests: Conditions for and... Medical and Other Health Services § 410.39 Prostate cancer screening tests: Conditions for and limitations... cancer screening tests means any of the following procedures furnished to an individual for the purpose...

  1. 42 CFR 410.39 - Prostate cancer screening tests: Conditions for and limitations on coverage.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 2 2012-10-01 2012-10-01 false Prostate cancer screening tests: Conditions for and... Medical and Other Health Services § 410.39 Prostate cancer screening tests: Conditions for and limitations... cancer screening tests means any of the following procedures furnished to an individual for the purpose...

  2. 42 CFR 410.39 - Prostate cancer screening tests: Conditions for and limitations on coverage.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 2 2013-10-01 2013-10-01 false Prostate cancer screening tests: Conditions for and... Medical and Other Health Services § 410.39 Prostate cancer screening tests: Conditions for and limitations... cancer screening tests means any of the following procedures furnished to an individual for the purpose...

  3. 42 CFR 410.39 - Prostate cancer screening tests: Conditions for and limitations on coverage.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 2 2014-10-01 2014-10-01 false Prostate cancer screening tests: Conditions for and... Medical and Other Health Services § 410.39 Prostate cancer screening tests: Conditions for and limitations... cancer screening tests means any of the following procedures furnished to an individual for the purpose...

  4. The relative importance of patient-reported barriers to colorectal cancer screening.

    PubMed

    Jones, Resa M; Woolf, Steven H; Cunningham, Tina D; Johnson, Robert E; Krist, Alex H; Rothemich, Stephen F; Vernon, Sally W

    2010-05-01

    Colorectal cancer (CRC) screening rates are suboptimal. The most important barriers identified by patients are poorly understood. A comprehensive assessment of barriers to all recommended modalities is needed. In 2007, a questionnaire was mailed to 6100 patients, aged 50-75 years, from 12 family medicine practices in the Virginia Ambulatory Care Outcomes Research Network. People aged 65-75 years and African Americans were oversampled. Patients were asked to rate 19-21 barriers to each of four recommended tests. In 2008, responses were coded on a 5-point scale; higher scores reflected stronger barrier endorsement. The response rate was 55% (n=3357). Approximately 40% of respondents were aged >/=65 years, 30% were African-American, and 73% were adherent to screening. A clinician's failure to suggest screening and not knowing testing was necessary received the highest mean scores as barriers. Financial concerns and misconceptions were also cited. Barrier scores differed depending on whether respondents were never screened, overdue for screening, or adherent to guidelines. The top five barriers for each modality included test-specific barriers (e.g., handling stool, bowel preparation), which often outranked generic barriers to screening. Not knowing testing was necessary was a top barrier for all tests but colonoscopy. Although physician advice and awareness of the need for screening are important, barriers to screening are not homogenous across tests, and test-specific barriers warrant consideration in designing strategies to improve screening rates. Barrier scores differ by screening status, highlighting the need to address prior screening experience. Evidence that patients are more familiar with colonoscopy than with other modalities suggests an opportunity to improve screening rates by educating patients about alternative tests. 2010 American Journal of Preventive Medicine. Published by Elsevier Inc. All rights reserved.

  5. Cumulative Incidence of False-Positive Results in Repeated, Multimodal Cancer Screening

    PubMed Central

    Croswell, Jennifer Miller; Kramer, Barnett S.; Kreimer, Aimee R.; Prorok, Phil C.; Xu, Jian-Lun; Baker, Stuart G.; Fagerstrom, Richard; Riley, Thomas L.; Clapp, Jonathan D.; Berg, Christine D.; Gohagan, John K.; Andriole, Gerald L.; Chia, David; Church, Timothy R.; Crawford, E. David; Fouad, Mona N.; Gelmann, Edward P.; Lamerato, Lois; Reding, Douglas J.; Schoen, Robert E.

    2009-01-01

    PURPOSE Multiple cancer screening tests have been advocated for the general population; however, clinicians and patients are not always well-informed of screening burdens. We sought to determine the cumulative risk of a false-positive screening result and the resulting risk of a diagnostic procedure for an individual participating in a multimodal cancer screening program. METHODS Data were analyzed from the intervention arm of the ongoing Prostate, Lung, Colorectal, and Ovarian (PLCO) Cancer Screening Trial, a randomized controlled trial to determine the effects of prostate, lung, colorectal, and ovarian cancer screening on disease-specific mortality. The 68,436 participants, aged 55 to 74 years, were randomized to screening or usual care. Women received serial serum tests to detect cancer antigen 125 (CA-125), transvaginal sonograms, posteroanterior-view chest radiographs, and flexible sigmoidoscopies. Men received serial chest radiographs, flexible sigmoidoscopies, digital rectal examinations, and serum prostate-specific antigen tests. Fourteen screening examinations for each sex were possible during the 3-year screening period. RESULTS After 14 tests, the cumulative risk of having at least 1 false-positive screening test is 60.4% (95% CI, 59.8%–61.0%) for men, and 48.8% (95% CI, 48.1%–49.4%) for women. The cumulative risk after 14 tests of undergoing an invasive diagnostic procedure prompted by a false-positive test is 28.5% (CI, 27.8%–29.3%) for men and 22.1% (95% CI, 21.4%–22.7%) for women. CONCLUSIONS For an individual in a multimodal cancer screening trial, the risk of a false-positive finding is about 50% or greater by the 14th test. Physicians should educate patients about the likelihood of false positives and resulting diagnostic interventions when counseling about cancer screening. PMID:19433838

  6. Diffusion-controlled reference material for VOC emissions testing: proof of concept.

    PubMed

    Cox, S S; Liu, Z; Little, J C; Howard-Reed, C; Nabinger, S J; Persily, A

    2010-10-01

    Because of concerns about indoor air quality, there is growing awareness of the need to reduce the rate at which indoor materials and products emit volatile organic compounds (VOCs). To meet consumer demand for low emitting products, manufacturers are increasingly submitting materials to independent laboratories for emissions testing. However, the same product tested by different laboratories can result in very different emissions profiles because of a general lack of test validation procedures. There is a need for a reference material that can be used as a known emissions source and that will have the same emission rate when tested by different laboratories under the same conditions. A reference material was created by loading toluene into a polymethyl pentene film. A fundamental emissions model was used to predict the toluene emissions profile. Measured VOC emissions profiles using small-chamber emissions tests compared reasonably well to the emissions profile predicted using the emissions model, demonstrating the feasibility of the proposed approach to create a diffusion-controlled reference material. To calibrate emissions test chambers and improve the reproducibility of VOC emission measurements among different laboratories, a reference material has been created using a polymer film loaded with a representative VOC. Initial results show that the film's VOC emission profile measured in a conventional test chamber compares well to predictions based on independently determined material/chemical properties and a fundamental emissions model. The use of such reference materials has the potential to build consensus and confidence in emissions testing as well as 'level the playing field' for product testing laboratories and manufacturers.

  7. 40 CFR 61.67 - Emission tests.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 9 2014-07-01 2014-07-01 false Emission tests. 61.67 Section 61.67... Emission tests. (a) Unless a waiver of emission testing is obtained under § 61.13, the owner or operator of a source to which this subpart applies shall test emissions from the source, (1) Within 90 days of...

  8. 40 CFR 61.67 - Emission tests.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 9 2013-07-01 2013-07-01 false Emission tests. 61.67 Section 61.67... Emission tests. (a) Unless a waiver of emission testing is obtained under § 61.13, the owner or operator of a source to which this subpart applies shall test emissions from the source, (1) Within 90 days of...

  9. Chlorophyll fluorescence emission as a reporter on cold tolerance in Arabidopsis thaliana accessions

    PubMed Central

    Mishra, Anamika; Höermiller, Imke I; Heyer, Arnd G; Nedbal, Ladislav

    2011-01-01

    Non-invasive, high-throughput screening methods are valuable tools in breeding for abiotic stress tolerance in plants. Optical signals such as chlorophyll fluorescence emission can be instrumental in developing new screening techniques. In order to examine the potential of chlorophyll fluorescence to reveal plant tolerance to low temperatures, we used a collection of nine Arabidopsis thaliana accessions and compared their fluorescence features with cold tolerance quantified by the well established electrolyte leakage method on detached leaves. We found that, during progressive cooling, the minimal chlorophyll fluorescence emission rose strongly and that this rise was highly dependent on the cold tolerance of the accessions. Maximum quantum yield of PSII photochemistry and steady state fluorescence normalized to minimal fluorescence were also highly correlated to the cold tolerance measured by the electrolyte leakage method. In order to further increase the capacity of the fluorescence detection to reveal the low temperature tolerance, we applied combinatorial imaging that employs plant classification based on multiple fluorescence features. We found that this method, by including the resolving power of several fluorescence features, can be well employed to detect cold tolerance already at mild sub-zero temperatures. Therefore, there is no need to freeze the screened plants to the largely damaging temperatures of around −15°C. This, together with the method's easy applicability, represents a major advantage of the fluorescence technique over the conventional electrolyte leakage method. PMID:21427532

  10. NASA Flexible Screen Propellant Management Device (PMD) Demonstration With Cryogenic Liquid

    NASA Technical Reports Server (NTRS)

    Wollen, Mark; Bakke, Victor; Baker, James

    2012-01-01

    While evaluating various options for liquid methane and liquid oxygen propellant management for lunar missions, Innovative Engineering Solutions (IES) conceived the flexible screen device as a potential simple alternative to conventional propellant management devices (PMD). An apparatus was designed and fabricated to test flexible screen devices in liquid nitrogen. After resolution of a number of issues (discussed in detail in the paper), a fine mesh screen (325 by 2300 wires per inch) spring return assembly was successfully tested. No significant degradation in the screen bubble point was observed either due to the screen stretching process or due to cyclic fatigue during testing. An estimated 30 to 50 deflection cycles, and approximately 3 to 5 thermal cycles, were performed on the final screen specimen, prior to and between formally recorded testing. These cycles included some "abusive" pressure cycling, where gas or liquid was driven through the screen at rates that produced differential pressures across the screen of several times the bubble point pressure. No obvious performance degradation or other changes were observed over the duration of testing. In summary, it is felt by the author that these simple tests validated the feasibility of the flexible screen PMD concept for use with cryogenic propellants.

  11. 42 CFR 411.15 - Particular services excluded from coverage.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... aneurysms (AAA), cardiovascular disease screening tests, diabetes screening tests, a screening... conditions and limitation specified in § 410.19 of this chapter. (13) In the case of cardiovascular disease screening tests for the early detection of cardiovascular disease or abnormalities associated with an...

  12. Colorectal Cancer Screening: Preferences, Past Behavior, and Future Intentions.

    PubMed

    Mansfield, Carol; Ekwueme, Donatus U; Tangka, Florence K L; Brown, Derek S; Smith, Judith Lee; Guy, Gery P; Li, Chunyu; Hauber, Brett

    2018-05-09

    Screening rates for colorectal cancer are below the Healthy People 2020 goal. There are several colorectal cancer screening tests that differ in terms of accuracy, recommended frequency, and administration. In this article, we compare how a set of personal characteristics correlates with preferences for colorectal cancer screening test attributes, past colorectal cancer screening behavior, and future colorectal cancer screening intentions. We conducted a discrete-choice experiment survey to assess relative preferences for attributes of colorectal cancer screening tests among adults aged 50-75 years in USA. We used a latent class logit model to identify classes of preferences and calculated willingness to pay for changes in test attributes. A set of personal characteristics were included in the latent class analysis and analyses of self-reported past screening behavior and self-assessed likelihood of future colorectal cancer screening. Latent class analysis identified three types of respondents. Class 1 valued test accuracy, class 2 valued removing polyps and avoiding discomfort, and class 3 valued cost. Having had a prior colonoscopy and a higher income were predictors of the likelihood of future screening and membership in classes 1 and 2. Health insurance and a self-reported higher risk of developing colorectal cancer were associated with prior screening and higher future screening intentions, but not class membership. We identified distinct classes of preferences focusing on different test features and personal characteristics associated with reported behavior and intentions. Healthcare providers should engage in a careful assessment of patient preferences when recommending colorectal cancer test options to encourage colorectal cancer screening uptake.

  13. Validation of the Lollipop Test: A Diagnostic Screening Test of School Readiness.

    ERIC Educational Resources Information Center

    Chew, Alex L.; Morris, John D.

    1984-01-01

    The validity of the Lollipop Test: A Diagnostic Screening Test of School Readiness was examined using the Metropolitan Readiness Test (MRT), Level I, Form Q, as the criterion. Appreciable concurrent validity was found across test batteries. Implications for school readiness screening are discussed. (Author/BS)

  14. A Quantitative Model for the Prediction of Sooting Tendency from Molecular Structure

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    St. John, Peter C.; Kairys, Paul; Das, Dhrubajyoti D.

    Particulate matter emissions negatively affect public health and global climate, yet newer fuel-efficient gasoline direct injection engines tend to produce more soot than their port-fuel injection counterparts. Fortunately, the search for sustainable biomass-based fuel blendstocks provides an opportunity to develop fuels that suppress soot formation in more efficient engine designs. However, as emissions tests are experimentally cumbersome and the search space for potential bioblendstocks is vast, new techniques are needed to estimate the sooting tendency of a diverse range of compounds. In this study, we develop a quantitative structure-activity relationship (QSAR) model of sooting tendency based on the experimental yieldmore » sooting index (YSI), which ranks molecules on a scale from n-hexane, 0, to benzene, 100. The model includes a rigorously defined applicability domain, and the predictive performance is checked using both internal and external validation. Model predictions for compounds in the external test set had a median absolute error of ~3 YSI units. An investigation of compounds that are poorly predicted by the model lends new insight into the complex mechanisms governing soot formation. Predictive models of soot formation can therefore be expected to play an increasingly important role in the screening and development of next-generation biofuels.« less

  15. A Quantitative Model for the Prediction of Sooting Tendency from Molecular Structure

    DOE PAGES

    St. John, Peter C.; Kairys, Paul; Das, Dhrubajyoti D.; ...

    2017-07-24

    Particulate matter emissions negatively affect public health and global climate, yet newer fuel-efficient gasoline direct injection engines tend to produce more soot than their port-fuel injection counterparts. Fortunately, the search for sustainable biomass-based fuel blendstocks provides an opportunity to develop fuels that suppress soot formation in more efficient engine designs. However, as emissions tests are experimentally cumbersome and the search space for potential bioblendstocks is vast, new techniques are needed to estimate the sooting tendency of a diverse range of compounds. In this study, we develop a quantitative structure-activity relationship (QSAR) model of sooting tendency based on the experimental yieldmore » sooting index (YSI), which ranks molecules on a scale from n-hexane, 0, to benzene, 100. The model includes a rigorously defined applicability domain, and the predictive performance is checked using both internal and external validation. Model predictions for compounds in the external test set had a median absolute error of ~3 YSI units. An investigation of compounds that are poorly predicted by the model lends new insight into the complex mechanisms governing soot formation. Predictive models of soot formation can therefore be expected to play an increasingly important role in the screening and development of next-generation biofuels.« less

  16. Development and verification of a model for estimating the screening utility in the detection of PCBs in transformer oil.

    PubMed

    Terakado, Shingo; Glass, Thomas R; Sasaki, Kazuhiro; Ohmura, Naoya

    2014-01-01

    A simple new model for estimating the screening performance (false positive and false negative rates) of a given test for a specific sample population is presented. The model is shown to give good results on a test population, and is used to estimate the performance on a sampled population. Using the model developed in conjunction with regulatory requirements and the relative costs of the confirmatory and screening tests allows evaluation of the screening test's utility in terms of cost savings. Testers can use the methods developed to estimate the utility of a screening program using available screening tests with their own sample populations.

  17. Rapid biochemical screening for Salmonella, Shigella, Yersinia, and Aeromonas isolates from stool specimens.

    PubMed Central

    De Ryck, R; Struelens, M J; Serruys, E

    1994-01-01

    Four screens for the rapid (4 to 6 h) biochemical detection of pathogens from enteric isolation media are described. The Salmonella screen consisted of Kligler iron agar (KIA), motility-indole-urea-tryptophan-deamination semisolid medium (MIU-TDA), and the o-nitrophenyl-beta-D-galactopyranoside (ONPG) test; the Shigella screen consisted of KIA, MIU-TDA, the ONPG test, and the lysine decarboxylation-indole test; the Yersinia screen consisted of a rhamnose broth; the Aeromonas screen consisted of a xylose agar plate. When tested on 2,102 fresh isolates and 71 stock strains, the screens correctly detected 212 enteric pathogens (sensitivity, 100%), with a specificity of 98.1%. PMID:8077408

  18. Cancer Screening Overview (PDQ®)—Patient Version

    Cancer.gov

    Cancer screening means looking for cancer before symptoms appear, when cancer may be easier to treat. Screening tests can help reduce the risk of dying from some cancers, but all tests have potential risks, too. Learn more about cancer screening and available tests in this expert-reviewed summary.

  19. Screening strategies for atrial fibrillation: a systematic review and cost-effectiveness analysis.

    PubMed

    Welton, Nicky J; McAleenan, Alexandra; Thom, Howard Hz; Davies, Philippa; Hollingworth, Will; Higgins, Julian Pt; Okoli, George; Sterne, Jonathan Ac; Feder, Gene; Eaton, Diane; Hingorani, Aroon; Fawsitt, Christopher; Lobban, Trudie; Bryden, Peter; Richards, Alison; Sofat, Reecha

    2017-05-01

    Atrial fibrillation (AF) is a common cardiac arrhythmia that increases the risk of thromboembolic events. Anticoagulation therapy to prevent AF-related stroke has been shown to be cost-effective. A national screening programme for AF may prevent AF-related events, but would involve a substantial investment of NHS resources. To conduct a systematic review of the diagnostic test accuracy (DTA) of screening tests for AF, update a systematic review of comparative studies evaluating screening strategies for AF, develop an economic model to compare the cost-effectiveness of different screening strategies and review observational studies of AF screening to provide inputs to the model. Systematic review, meta-analysis and cost-effectiveness analysis. Primary care. Adults. Screening strategies, defined by screening test, age at initial and final screens, screening interval and format of screening {systematic opportunistic screening [individuals offered screening if they consult with their general practitioner (GP)] or systematic population screening (when all eligible individuals are invited to screening)}. Sensitivity, specificity and diagnostic odds ratios; the odds ratio of detecting new AF cases compared with no screening; and the mean incremental net benefit compared with no screening. Two reviewers screened the search results, extracted data and assessed the risk of bias. A DTA meta-analysis was perfomed, and a decision tree and Markov model was used to evaluate the cost-effectiveness of the screening strategies. Diagnostic test accuracy depended on the screening test and how it was interpreted. In general, the screening tests identified in our review had high sensitivity (> 0.9). Systematic population and systematic opportunistic screening strategies were found to be similarly effective, with an estimated 170 individuals needed to be screened to detect one additional AF case compared with no screening. Systematic opportunistic screening was more likely to be cost-effective than systematic population screening, as long as the uptake of opportunistic screening observed in randomised controlled trials translates to practice. Modified blood pressure monitors, photoplethysmography or nurse pulse palpation were more likely to be cost-effective than other screening tests. A screening strategy with an initial screening age of 65 years and repeated screens every 5 years until age 80 years was likely to be cost-effective, provided that compliance with treatment does not decline with increasing age. A national screening programme for AF is likely to represent a cost-effective use of resources. Systematic opportunistic screening is more likely to be cost-effective than systematic population screening. Nurse pulse palpation or modified blood pressure monitors would be appropriate screening tests, with confirmation by diagnostic 12-lead electrocardiography interpreted by a trained GP, with referral to a specialist in the case of an unclear diagnosis. Implementation strategies to operationalise uptake of systematic opportunistic screening in primary care should accompany any screening recommendations. Many inputs for the economic model relied on a single trial [the Screening for Atrial Fibrillation in the Elderly (SAFE) study] and DTA results were based on a few studies at high risk of bias/of low applicability. Comparative studies measuring long-term outcomes of screening strategies and DTA studies for new, emerging technologies and to replicate the results for photoplethysmography and GP interpretation of 12-lead electrocardiography in a screening population. This study is registered as PROSPERO CRD42014013739. The National Institute for Health Research Health Technology Assessment programme.

  20. 21 CFR 1270.21 - Determination of donor suitability for human tissue intended for transplantation.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... virus, Type 1 (e.g., FDA licensed screening test for anti-HIV-1); (2) Human immunodeficiency virus, Type 2 (e.g., FDA licensed screening test for anti-HIV-2); (3) Hepatitis B (e.g., FDA licensed screening... been tested and found negative using FDA licensed screening tests for HIV-1, HIV-2, hepatitis B, and...

  1. 21 CFR 1270.21 - Determination of donor suitability for human tissue intended for transplantation.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... virus, Type 1 (e.g., FDA licensed screening test for anti-HIV-1); (2) Human immunodeficiency virus, Type 2 (e.g., FDA licensed screening test for anti-HIV-2); (3) Hepatitis B (e.g., FDA licensed screening... been tested and found negative using FDA licensed screening tests for HIV-1, HIV-2, hepatitis B, and...

  2. 21 CFR 1270.21 - Determination of donor suitability for human tissue intended for transplantation.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... virus, Type 1 (e.g., FDA licensed screening test for anti-HIV-1); (2) Human immunodeficiency virus, Type 2 (e.g., FDA licensed screening test for anti-HIV-2); (3) Hepatitis B (e.g., FDA licensed screening... been tested and found negative using FDA licensed screening tests for HIV-1, HIV-2, hepatitis B, and...

  3. 21 CFR 1270.21 - Determination of donor suitability for human tissue intended for transplantation.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... virus, Type 1 (e.g., FDA licensed screening test for anti-HIV-1); (2) Human immunodeficiency virus, Type 2 (e.g., FDA licensed screening test for anti-HIV-2); (3) Hepatitis B (e.g., FDA licensed screening... been tested and found negative using FDA licensed screening tests for HIV-1, HIV-2, hepatitis B, and...

  4. Test equality between two binary screening tests with a confirmatory procedure restricted on screen positives.

    PubMed

    Lui, Kung-Jong; Chang, Kuang-Chao

    2015-01-01

    In studies of screening accuracy, we may commonly encounter the data in which a confirmatory procedure is administered to only those subjects with screen positives for ethical concerns. We focus our discussion on simultaneously testing equality of sensitivity and specificity between two binary screening tests when only subjects with screen positives receive the confirmatory procedure. We develop four asymptotic test procedures and one exact test procedure. We derive sample size calculation formula for a desired power of detecting a difference at a given nominal [Formula: see text]-level. We employ Monte Carlo simulation to evaluate the performance of these test procedures and the accuracy of the sample size calculation formula developed here in a variety of situations. Finally, we use the data obtained from a study of the prostate-specific-antigen test and digital rectal examination test on 949 Black men to illustrate the practical use of these test procedures and the sample size calculation formula.

  5. Endometrial Cancer Screening

    MedlinePlus

    ... decrease the risk of dying from cancer. Scientists study screening tests to find those with the fewest risks and ... recovery. There is no standard or routine screening test for endometrial cancer. Screening for endometrial cancer is under study and there are screening clinical trials taking place ...

  6. Esophageal Cancer Screening

    MedlinePlus

    ... decrease the risk of dying from cancer. Scientists study screening tests to find those with the fewest risks and ... stage . There is no standard or routine screening test for esophageal cancer. Screening for esophageal cancer is under study with screening clinical trials taking place in many ...

  7. Colorectal Cancer Screening: Recommendations for Physicians and Patients from the U.S. Multi-Society Task Force on Colorectal Cancer.

    PubMed

    Rex, Douglas K; Boland, C Richard; Dominitz, Jason A; Giardiello, Francis M; Johnson, David A; Kaltenbach, Tonya; Levin, Theodore R; Lieberman, David; Robertson, Douglas J

    2017-07-01

    This document updates the colorectal cancer (CRC) screening recommendations of the U.S. Multi-Society Task Force of Colorectal Cancer (MSTF), which represents the American College of Gastroenterology, the American Gastroenterological Association, and The American Society for Gastrointestinal Endoscopy. CRC screening tests are ranked in 3 tiers based on performance features, costs, and practical considerations. The first-tier tests are colonoscopy every 10 years and annual fecal immunochemical test (FIT). Colonoscopy and FIT are recommended as the cornerstones of screening regardless of how screening is offered. Thus, in a sequential approach based on colonoscopy offered first, FIT should be offered to patients who decline colonoscopy. Colonoscopy and FIT are recommended as tests of choice when multiple options are presented as alternatives. A risk-stratified approach is also appropriate, with FIT screening in populations with an estimated low prevalence of advanced neoplasia and colonoscopy screening in high prevalence populations. The second-tier tests include CT colonography every 5 years, the FIT-fecal DNA test every 3 years, and flexible sigmoidoscopy every 5 to 10 years. These tests are appropriate screening tests, but each has disadvantages relative to the tier 1 tests. Because of limited evidence and current obstacles to use, capsule colonoscopy every 5 years is a third-tier test. We suggest that the Septin9 serum assay (Epigenomics, Seattle, Wash) not be used for screening. Screening should begin at age 50 years in average-risk persons, except in African Americans in whom limited evidence supports screening at 45 years. CRC incidence is rising in persons under age 50, and thorough diagnostic evaluation of young persons with suspected colorectal bleeding is recommended. Discontinuation of screening should be considered when persons up to date with screening, who have prior negative screening (particularly colonoscopy), reach age 75 or have <10 years of life expectancy. Persons without prior screening should be considered for screening up to age 85, depending on age and comorbidities. Persons with a family history of CRC or a documented advanced adenoma in a first-degree relative age <60 years or 2 first-degree relatives with these findings at any age are recommended to undergo screening by colonoscopy every 5 years, beginning 10 years before the age at diagnosis of the youngest affected relative or age 40, whichever is earlier. Persons with a single first-degree relative diagnosed at ≥60 years with CRC or an advanced adenoma can be offered average-risk screening options beginning at age 40 years.

  8. Screening for diabetes and prediabetes should be cost-saving in patients at high risk.

    PubMed

    Chatterjee, Ranee; Narayan, K M Venkat; Lipscomb, Joseph; Jackson, Sandra L; Long, Qi; Zhu, Ming; Phillips, Lawrence S

    2013-07-01

    Although screening for diabetes and prediabetes is recommended, it is not clear how best or whom to screen. We therefore compared the economics of screening according to baseline risk. Five screening tests were performed in 1,573 adults without known diabetes--random plasma/capillary glucose, plasma/capillary glucose 1 h after 50-g oral glucose (any time, without previous fast, plasma glucose 1 h after a 50-g oral glucose challenge [GCTpl]/capillary glucose 1 h after a 50-g oral glucose challenge [GCTcap]), and A1C--and a definitive 75-g oral glucose tolerance test. Costs of screening included the following: costs of testing (screen plus oral glucose tolerance test, if screen is positive); costs for false-negative results; and costs of treatment of true-positive results with metformin, all over the course of 3 years. We compared costs for no screening, screening everyone for diabetes or high-risk prediabetes, and screening those with risk factors based on age, BMI, blood pressure, waist circumference, lipids, or family history of diabetes. Compared with no screening, cost-savings would be obtained largely from screening those at higher risk, including those with BMI >35 kg/m(2), systolic blood pressure ≥130 mmHg, or age >55 years, with differences of up to -46% of health system costs for screening for diabetes and -21% for screening for dysglycemia110, respectively (all P < 0.01). GCTpl would be the least expensive screening test for most high-risk groups for this population over the course of 3 years. From a health economics perspective, screening for diabetes and high-risk prediabetes should target patients at higher risk, particularly those with BMI >35 kg/m(2), systolic blood pressure ≥130 mmHg, or age >55 years, for whom screening can be most cost-saving. GCTpl is generally the least expensive test in high-risk groups and should be considered for routine use as an opportunistic screen in these groups.

  9. The effects and outcomes of electrolyte disturbances and asphyxia on newborns hearing

    PubMed Central

    Liang, Chun; Hong, Qi; Jiang, Tao-Tao; Gao, Yan; Yao, Xiao-Fang; Luo, Xiao-Xing; Zhuo, Xiu-Hui; Shinn, Jennifer B.; Jones, Raleigh O.; Zhao, Hong-Bo; Lu, Guang-Jin

    2013-01-01

    Objective To determine the effect of electrolyte disturbances (ED) and asphyxia on infant hearing and hearing outcomes. Study Design We conducted newborn hearing screening with transient evoked otoacoustic emission (TEOAE) test on a large scale (>5,000 infants). The effects of ED and asphyxia on infant hearing and hearing outcomes were evaluated. Result The pass rate of TEOAE test was significantly reduced in preterm infants with ED (83.1%, multiple logistic regression analysis: P<0.01) but not in full-term infants with ED (93.6%, P=0.41). However, there was no significant reduction in the pass rate in infants with asphyxia (P=0.85). We further found that hypocalcaemia significantly reduced the pass rate of TEOAE test (86.8%, P<0.01). In the follow-up recheck at 3 months of age, the pass rate remained low (44.4%, P<0.01). Conclusion ED is a high-risk factor for preterm infant hearing. Hypocalcaemia can produce more significant impairment with a low recovery rate. PMID:23648318

  10. Estimation of methane emission from California natural gas industry.

    PubMed

    Kuo, Jeff; Hicks, Travis C; Drake, Brian; Chan, Tat Fu

    2015-07-01

    Energy generation and consumption are the main contributors to greenhouse gases emissions in California. Natural gas is one of the primary sources of energy in California. A study was recently conducted to develop current, reliable, and California-specific source emission factors (EFs) that could be used to establish a more accurate methane emission inventory for the California natural gas industry. Twenty-five natural gas facilities were surveyed; the surveyed equipment included wellheads (172), separators (131), dehydrators (17), piping segments (145), compressors (66), pneumatic devices (374), metering and regulating (M&R) stations (19), hatches (34), pumps (2), and customer meters (12). In total, 92,157 components were screened, including flanges (10,101), manual valves (10,765), open-ended lines (384), pressure relief valves (358), regulators (930), seals (146), threaded connections (57,061), and welded connections (12,274). Screening values (SVs) were measured using portable monitoring instruments, and Hi-Flow samplers were then used to quantify fugitive emission rates. For a given SV range, the measured leak rates might span several orders of magnitude. The correlation equations between the leak rates and SVs were derived. All the component leakage rate histograms appeared to have the same trend, with the majority of leakage rates<0.02 cubic feet per minute (cfm). Using the cumulative distribution function, the geometric mean was found to be a better indicator than the arithmetic mean, as the mean for each group of leakage rates found. For most component types, the pegged EFs for SVs of ≥10,000 ppmV and of ≥50,000 ppmV are relatively similar. The component-level average EFs derived in this study are often smaller than the corresponding ones in the 1996 U.S. Environmental Protection Agency/Gas Research Institute (EPA/GRI) study. Twenty-five natural gas facilities in California were surveyed to develop current, reliable, and California-specific source emission factors (EFs) for the natural gas industry. Screening values were measured by using portable monitoring instruments, and Hi-Flow samplers were then used to quantify fugitive emission rates. The component-level average EFs derived in this study are often smaller than the corresponding ones in the 1996 EPA/GRI study. The smaller EF values from this study might be partially attributable to the employment of the leak detection and repair program by most, if not all, of the facilities surveyed.

  11. Accuracy and Cost-Effectiveness of Cervical Cancer Screening by High-Risk HPV DNA Testing of Self-Collected Vaginal Samples

    PubMed Central

    Balasubramanian, Akhila; Kulasingam, Shalini L.; Baer, Atar; Hughes, James P.; Myers, Evan R.; Mao, Constance; Kiviat, Nancy B.; Koutsky, Laura A.

    2010-01-01

    Objective Estimate the accuracy and cost-effectiveness of cervical cancer screening strategies based on high-risk HPV DNA testing of self-collected vaginal samples. Materials and Methods A subset of 1,665 women (18-50 years of age) participating in a cervical cancer screening study were screened by liquid-based cytology and by high-risk HPV DNA testing of both self-collected vaginal swab samples and clinician-collected cervical samples. Women with positive/abnormal screening test results and a subset of women with negative screening test results were triaged to colposcopy. Based on individual and combined test results, five screening strategies were defined. Estimates of sensitivity and specificity for cervical intraepithelial neoplasia grade 2 or worse were calculated and a Markov model was used to estimate the incremental cost-effectiveness ratios (ICERs) for each strategy. Results Compared to cytology-based screening, high-risk HPV DNA testing of self-collected vaginal samples was more sensitive (68%, 95%CI=58%-78% versus 85%, 95%CI=76%-94%) but less specific (89%, 95%CI=86%-91% versus 73%, 95%CI=67%-79%). A strategy of high-risk HPV DNA testing of self-collected vaginal samples followed by cytology triage of HPV positive women, was comparably sensitive (75%, 95%CI=64%-86%) and specific (88%, 95%CI=85%-92%) to cytology-based screening. In-home self-collection for high-risk HPV DNA detection followed by in-clinic cytology triage had a slightly lower lifetime cost and a slightly higher quality-adjusted life expectancy than did cytology-based screening (ICER of triennial screening compared to no screening was $9,871/QALY and $12,878/QALY, respectively). Conclusions Triennial screening by high-risk HPV DNA testing of in-home, self-collected vaginal samples followed by in-clinic cytology triage was cost-effective. PMID:20592553

  12. Emission measurement of diesel vehicles in Hong Kong through on-road remote sensing: Performance review and identification of high-emitters.

    PubMed

    Huang, Yuhan; Organ, Bruce; Zhou, John L; Surawski, Nic C; Hong, Guang; Chan, Edward F C; Yam, Yat Shing

    2018-06-01

    A two-year remote sensing measurement program was carried out in Hong Kong to obtain a large dataset of on-road diesel vehicle emissions. Analysis was performed to evaluate the effect of vehicle manufacture year (1949-2015) and engine size (0.4-20 L) on the emission rates and high-emitters. The results showed that CO emission rates of larger engine size vehicles were higher than those of small vehicles during the study period, while HC and NO were higher before manufacture year 2006 and then became similar levels between manufacture years 2006 and 2015. CO, HC and NO of all vehicles showed an unexpectedly increasing trend during 1998-2004, in particular ≥6001 cc vehicles. However, they all decreased steadily in the last decade (2005-2015), except for NO of ≥6001 cc vehicles during 2013-2015. The distributions of CO and HC emission rates were highly skewed as the dirtiest 10% vehicles emitted much higher emissions than all the other vehicles. Moreover, this skewness became more significant for larger engine size or newer vehicles. The results indicated that remote sensing technology would be very effective to screen the CO and HC high-emitters and thus control the on-road vehicle emissions, but less effective for controlling NO emissions. No clear correlation was observed between the manufacture year and percentage of high-emitters for ≤3000 cc vehicles. However, the percentage of high-emitters decreased with newer manufacture year for larger vehicles. In addition, high-emitters of different pollutants were relatively independent, in particular NO emissions, indicating that high-emitter screening criteria should be defined on a CO-or-HC-or-NO basis, rather than a CO-and-HC-and-NO basis. Copyright © 2018 Elsevier Ltd. All rights reserved.

  13. 40 CFR 86.1360-2007 - Supplemental emission test; test cycle and procedures.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 19 2010-07-01 2010-07-01 false Supplemental emission test; test cycle... ENGINES (CONTINUED) Emission Regulations for New Otto-Cycle and Diesel Heavy-Duty Engines; Gaseous and Particulate Exhaust Test Procedures § 86.1360-2007 Supplemental emission test; test cycle and procedures. The...

  14. Hepatitis C virus testing in adults living with HIV: a need for improved screening efforts.

    PubMed

    Yehia, Baligh R; Herati, Ramin S; Fleishman, John A; Gallant, Joel E; Agwu, Allison L; Berry, Stephen A; Korthuis, P Todd; Moore, Richard D; Metlay, Joshua P; Gebo, Kelly A

    2014-01-01

    Guidelines recommend hepatitis C virus (HCV) screening for all people living with HIV (PLWH). Understanding HCV testing practices may improve compliance with guidelines and can help identify areas for future intervention. We evaluated HCV screening and unnecessary repeat HCV testing in 8,590 PLWH initiating care at 12 U.S. HIV clinics between 2006 and 2010, with follow-up through 2011. Multivariable logistic regression examined the association between patient factors and the outcomes: HCV screening (≥1 HCV antibody tests during the study period) and unnecessary repeat HCV testing (≥1 HCV antibody tests in patients with a prior positive test result). Overall, 82% of patients were screened for HCV, 18% of those screened were HCV antibody-positive, and 40% of HCV antibody-positive patients had unnecessary repeat HCV testing. The likelihood of being screened for HCV increased as the number of outpatient visits rose (adjusted odds ratio 1.02, 95% confidence interval 1.01-1.03). Compared to men who have sex with men (MSM), patients with injection drug use (IDU) were less likely to be screened for HCV (0.63, 0.52-0.78); while individuals with Medicaid were more likely to be screened than those with private insurance (1.30, 1.04-1.62). Patients with heterosexual (1.78, 1.20-2.65) and IDU (1.58, 1.06-2.34) risk compared to MSM, and those with higher numbers of outpatient (1.03, 1.01-1.04) and inpatient (1.09, 1.01-1.19) visits were at greatest risk of unnecessary HCV testing. Additional efforts to improve compliance with HCV testing guidelines are needed. Leveraging health information technology may increase HCV screening and reduce unnecessary testing.

  15. The cost of implementation of the Clinical Laboratory Improvement Amendments of 1988--the example of pediatric office-based cholesterol screening.

    PubMed

    Tershakovec, A M; Brannon, S D; Bennett, M J; Shannon, B M

    1995-08-01

    To measure the additional costs of office-based laboratory testing due to the implementation of the Clinical Laboratory Improvement Amendments of 1988 (CLIA '88), using cholesterol screening for children as an example. Four- to ten-year-old children who received their well child care at one of seven participating pediatric practices were screened for hypercholesterolemia. The average number of analyses per day and days per month were derived from the volume of testing completed by the practices. Nurses and technicians time in the screening process were measured and personnel costs were calculated based on salary and fringe benefit rates. Costs of supplies, analyzing control samples, instrument calibration, and instrument depreciation were included. Costs estimates of screening were then completed. CLIA '88 implementation costs were derived from appropriate proficiency testing and laboratory inspection programs. In six practices completing a low volume of testing, 2807 children (5 to 6 children per week) were screened during the observation period, while 414 (about 25 children per week) were screened in one high-volume practice implementing universal screening over a 4-month period. For the six low-volume practices, the cost of screening was $10.60 per child. This decreased to $5.47 for the high-volume practice. Estimated costs of CLIA '88 implementation, including additional proficiency testing and laboratory inspection, added $3.20 per test for the low-volume practices, and $0.71 per test for the high-volume testing. Implementation of CLIA adds significantly to the cost of office-based chemistry laboratory screening. Despite these additional expenses, the cost of testing is still within a reasonable charge for laboratory testing, and is highly sensitive to the volume of tests completed.

  16. Environmental and risk screening for prioritizing pollution prevention opportunities in the U.S. printed wiring board manufacturing industry.

    PubMed

    Lam, Carl W; Lim, Seong-Rin; Schoenung, Julie M

    2011-05-15

    Modern manufacturing of printed wiring boards (PWBs) involves extensive use of various hazardous chemicals in different manufacturing steps such as board preparation, circuit design transfer, etching and plating processes. Two complementary environmental screening methods developed by the U.S. EPA, namely: (i) the Tool for the Reduction and Assessment of Chemical and Other Environmental Impacts (TRACI) and (ii) Risk-Screening Environmental Indicators (RSEI), are used to quantify geographic and chemical environmental impacts in the U.S. PWB manufacturing industry based on Toxics Release Inventory (TRI) data. Although the release weight percentages of industrial chemicals such as methanol, glycol ethers and dimethylformamide comprise the larger fraction of reported air and water emissions, results indicate that lead, copper and their compounds' releases correspond to the highest environmental impact from toxicity potentials and risk-screening scores. Combining these results with further knowledge of PWB manufacturing, select alternative chemical processes and materials for pollution prevention are discussed. Examples of effective pollution prevention options in the PWB industry include spent etchant recovery technologies, and process and material substitutions. In addition, geographic assessment of environmental burden highlights states where promotion of pollution prevention strategies and emissions regulations can have the greatest effect to curb the PWB industry's toxic release impacts. Copyright © 2011 Elsevier B.V. All rights reserved.

  17. First-trimester contingent screening for trisomies 21, 18 and 13 by biomarkers and maternal blood cell-free DNA testing.

    PubMed

    Nicolaides, K H; Syngelaki, A; Poon, L C; Gil, M M; Wright, D

    2014-01-01

    To examine potential performance of screening for trisomies by cell-free (cf) DNA testing in maternal blood contingent on results of first-line testing by combinations of fetal translucency thickness (NT), fetal heart rate (FHR), ductus venosus pulsatility index (DV PIV), and serum-free β-human chorionic gonadotropin (β-hCG), pregnancy-associated plasma protein-A (PAPP-A), placental growth factor (PLGF) and α-fetoprotein (AFP). Performance was estimated for firstly, screening by cfDNA in all pregnancies and secondly, cfDNA testing contingent on results of first-line testing by combinations of ultrasound and biochemical markers. In first-line screening by cfDNA testing, the detection rate for trisomy 21 and trisomies 18 or 13 would be 99 and 96%, respectively, after invasive testing in 1% of the population. In contingent screening, a detection rate of 98% for trisomy 21 and 96% for trisomy 18 or 13, at an invasive testing rate of 0.7%, can be achieved by carrying out cfDNA testing in about 35, 20 and 11% of cases identified by first-line screening with the combined test alone (age, NT, FHR, β-hCG, PAPP-A), the combined test plus PLGF and AFP and the combined test plus PLGF, AFP and DV PIV, respectively. Effective first-trimester screening for trisomies can be achieved by contingent screening incorporating biomarkers and cfDNA testing. © 2013 S. Karger AG, Basel.

  18. Age-specific performance of careHPV versus Papanicolaou and visual inspection of cervix with acetic acid testing in a primary cervical cancer screening.

    PubMed

    Labani, Satyanarayana; Asthana, Smita

    2016-01-01

    Human papillomavirus (HPV) is recommended as a primary screening tool for cervical screening. Assessment of age-specific performance of newer HPV careHPV DNA testing is important as risk of cervical intraepithelial neoplasia (CIN) varies at different ages. We aim to evaluate careHPV in comparison to Papanicolaou (Pap) test and visual inspection of the cervix with acetic acid (VIA) cervical screening tests for the detection of high-grade CIN. The cross sectional study was conducted in a rural population of North India. Ever-married women 30-59 years of age were invited for screening by careHPV (self-collected vaginal and physician-collected cervical samples), Pap test and VIA. Associations for trend in age for detecting histological-confirmed CINII+ and CINIII+ for each screening test were evaluated. Age-specific association with each screening test was evaluated. Of a total of 7761 women invited, 5032 were screened and analysis was performed on 4658 with all screen test results. No significant (p>0.05) association of age for any screening test in the detection of CINII+ or CINIII+ was observed. For the older age group, cervical HPV (CHPV) showed high sensitivity and specificity for CINII+ detection. Specificity of CHPV or vaginal HPV (VHPV) was equal or higher than Pap in all age groups. Cervical screening options of CHPV or VHPV, or Pap, performed equally in the younger age group while CHPV might be an option for all ages in the detection of high-grade CIN. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  19. Investigation on the Plasma-Induced Emission Properties of Large Area Carbon Nanotube Array Cathodes with Different Morphologies

    PubMed Central

    2011-01-01

    Large area well-aligned carbon nanotube (CNT) arrays with different morphologies were synthesized by using a chemical vapor deposition. The plasma-induced emission properties of CNT array cathodes with different morphologies were investigated. The ratio of CNT height to CNT-to-CNT distance has considerable effects on their plasma-induced emission properties. As the ratio increases, emission currents of CNT array cathodes decrease due to screening effects. Under the pulse electric field of about 6 V/μm, high-intensity electron beams of 170–180 A/cm2 were emitted from the surface plasma. The production mechanism of the high-intensity electron beams emitted from the CNT arrays was plasma-induced emission. Moreover, the distribution of the electron beams was in situ characterized by the light emission from the surface plasma. PMID:27502662

  20. Investigation on the Plasma-Induced Emission Properties of Large Area Carbon Nanotube Array Cathodes with Different Morphologies.

    PubMed

    Liao, Qingliang; Qin, Zi; Zhang, Zheng; Qi, Junjie; Zhang, Yue; Huang, Yunhua; Liu, Liang

    2011-12-01

    Large area well-aligned carbon nanotube (CNT) arrays with different morphologies were synthesized by using a chemical vapor deposition. The plasma-induced emission properties of CNT array cathodes with different morphologies were investigated. The ratio of CNT height to CNT-to-CNT distance has considerable effects on their plasma-induced emission properties. As the ratio increases, emission currents of CNT array cathodes decrease due to screening effects. Under the pulse electric field of about 6 V/μm, high-intensity electron beams of 170-180 A/cm(2) were emitted from the surface plasma. The production mechanism of the high-intensity electron beams emitted from the CNT arrays was plasma-induced emission. Moreover, the distribution of the electron beams was in situ characterized by the light emission from the surface plasma.

  1. Risks of Esophageal Cancer Screening

    MedlinePlus

    ... decrease the risk of dying from cancer. Scientists study screening tests to find those with the fewest risks and ... stage . There is no standard or routine screening test for esophageal cancer. Screening for esophageal cancer is under study with screening clinical trials taking place in many ...

  2. Risks of Endometrial Cancer Screening

    MedlinePlus

    ... decrease the risk of dying from cancer. Scientists study screening tests to find those with the fewest risks and ... recovery. There is no standard or routine screening test for endometrial cancer. Screening for endometrial cancer is under study and there are screening clinical trials taking place ...

  3. Screening with Papanicolaou tests in Alberta

    PubMed Central

    Symonds, Christopher J.; Chen, Wenxin; Rose, Marianne Sarah; Cooke, Lara J.

    2018-01-01

    Abstract Objective To describe the prevalence and geographic distribution of cervical cancer screening, as well as the age groups of those undergoing screening, in Alberta, and to determine if screening practices conform to current guidelines and follow Choosing Wisely Canada recommendations. Design Descriptive study using data from the Alberta Ministry of Health Analytics and Performance Reporting Branch. Setting Alberta. Participants Women who had 1 or more Papanicolaou tests between 2011 and 2013. Main outcome measures Number of women aged 15 to 20 and those aged 70 and older who had 1 or more Pap tests in a 3-year period; year-to-year trends in screening rates for women in these 2 age groups; trends in screening rates in various geographic regions (ie, cities and zones) in Alberta; and the discipline of clinicians who ordered the Pap tests. Results Between 2011 and 2013, 805 632 women in the province of Alberta had 1 or more Pap tests for cervical cancer screening. Overall, 25 511 (17.5%) women aged 15 to 20 and 16 818 (10.3%) aged 70 and older were screened contrary to most existing guidelines. Screening rates varied markedly in different geographic regions of the province. Most Pap tests were ordered by family physicians or general practitioners. Conclusion Within the geographic regions of Alberta, provincial, national, and international guidelines for screening with Pap tests are inconsistently followed. This strongly echoes the need for clinicians and patients to consider the Choosing Wisely Canada recommendations and current guidelines for cervical cancer screening. PMID:29358254

  4. EPA Webinar on the Energy Efficiency/Renewable Energy Manual

    EPA Pesticide Factsheets

    existing EPA EE/RE SIP guidance, policies and programs in the jurisdiction, electric energy system, roles and responsibilities of key state energy-related organizations, emission benefits, screening analysis

  5. Node-pore sensing enables label-free surface-marker profiling of single cells.

    PubMed

    Balakrishnan, Karthik R; Whang, Jeremy C; Hwang, Richard; Hack, James H; Godley, Lucy A; Sohn, Lydia L

    2015-03-03

    Flow cytometry is a ubiquitous, multiparametric method for characterizing cellular populations. However, this method can grow increasingly complex with the number of proteins that need to be screened simultaneously: spectral emission overlap of fluorophores and the subsequent need for compensation, lengthy sample preparation, and multiple control tests that need to be performed separately must all be considered. These factors lead to increased costs, and consequently, flow cytometry is performed in core facilities with a dedicated technician operating the instrument. Here, we describe a low-cost, label-free microfluidic method that can determine the phenotypic profiles of single cells. Our method employs Node-Pore Sensing to measure the transit times of cells as they interact with a series of different antibodies, each corresponding to a specific cell-surface antigen, that have been functionalized in a single microfluidic channel. We demonstrate the capabilities of our method not only by screening two acute promyelocytic leukemia human cells lines (NB4 and AP-1060) for myeloid antigens, CD13, CD14, CD15, and CD33, simultaneously, but also by distinguishing a mixture of cells of similar size—AP-1060 and NALM-1—based on surface markers CD13 and HLA-DR. Furthermore, we show that our method can screen complex subpopulations in clinical samples: we successfully identified the blast population in primary human bone marrow samples from patients with acute myeloid leukemia and screened these cells for CD13, CD34, and HLA-DR. We show that our label-free method is an affordable, highly sensitive, and user-friendly technology that has the potential to transform cellular screening at the benchside.

  6. Hearing loss screening tool (COBRA score) for newborns in primary care setting

    PubMed Central

    Poonual, Watcharapol; Navacharoen, Niramon; Kangsanarak, Jaran; Namwongprom, Sirianong

    2017-01-01

    Purpose To develop and evaluate a simple screening tool to assess hearing loss in newborns. A derived score was compared with the standard clinical practice tool. Methods This cohort study was designed to screen the hearing of newborns using transiently evoked otoacoustic emission and auditory brain stem response, and to determine the risk factors associated with hearing loss of newborns in 3 tertiary hospitals in Northern Thailand. Data were prospectively collected from November 1, 2010 to May 31, 2012. To develop the risk score, clinical-risk indicators were measured by Poisson risk regression. The regression coefficients were transformed into item scores dividing each regression-coefficient with the smallest coefficient in the model, rounding the number to its nearest integer, and adding up to a total score. Results Five clinical risk factors (Craniofacial anomaly, Ototoxicity, Birth weight, family history [Relative] of congenital sensorineural hearing loss, and Apgar score) were included in our COBRA score. The screening tool detected, by area under the receiver operating characteristic curve, more than 80% of existing hearing loss. The positive-likelihood ratio of hearing loss in patients with scores of 4, 6, and 8 were 25.21 (95% confidence interval [CI], 14.69–43.26), 58.52 (95% CI, 36.26–94.44), and 51.56 (95% CI, 33.74–78.82), respectively. This result was similar to the standard tool (The Joint Committee on Infant Hearing) of 26.72 (95% CI, 20.59–34.66). Conclusion A simple screening tool of five predictors provides good prediction indices for newborn hearing loss, which may motivate parents to bring children for further appropriate testing and investigations. PMID:29234358

  7. Additional mailing phase for FIT after a medical offer phase: The best way to improve compliance with colorectal cancer screening in France.

    PubMed

    Piette, Christine; Durand, Gérard; Bretagne, Jean-François; Faivre, Jean

    2017-03-01

    Compliance with colorectal cancer screening is critical to its effectiveness. The organisation of the mass screening programme in France has recently been modified with no evaluation of the consequences. To evaluate the impact of the way the screening test is delivered on compliance. During the first six months of the screening campaign (Ille-Vilaine, Brittany), general practitioners were asked to propose a faecal immunochemical test (FIT), OC-Sensor, to individuals at average risk for colorectal cancer (n=152,097). A subset of non-participants in the medical phase (n=13,071) was randomly chosen to receive a reminder that included the screening test or a simple postal reminder without the screening test. Compliance was 31% if the screening test was proposed during a medical consultation. In non-participants during the medical phase, it was 45% in those receiving both a reminder and the screening test and 28% amongst those receiving a simple reminder. An estimated overall participation rate of 54% can be expected if non-participants in the medical phase are sent a reminder together with the screening test. In France, a compliance rate above the minimum uptake rate of 45% recommended by European Union experts can be achieved if the FIT is mailed to non-participants after the medical free-offer phase. Copyright © 2016. Published by Elsevier Ltd.

  8. Measurements of reciprocity law failure in green-sensitive X-ray films.

    PubMed

    Arnold, B A; Eisenberg, H; Bjärngard, B E

    1978-02-01

    Reciprocity law failure was measured for four brands of medical x-ray films exposed with intensifying screens. Three of the films are green light-sensitized for use in combination with green light-emitting rare-earth screens. These films showed larger reciprocity failure effects than one conventional blue-sensitive film, Dupont Cronex-2. Development conditions had a small effect on reciprocity failure. As part of the investigation, a detector was constructed with a response that accurately monitors the light emission from the double screen-cassette combination over a wide range of x-ray photon energies.

  9. Prediction of permanent hearing loss in high-risk preterm infants at term age.

    PubMed

    Valkama, A M; Laitakari, K T; Tolonen, E U; Väyrynen, M R; Vainionpää, L K; Koivisto, M E

    2000-06-01

    The aim of this series was to assess hearing screenings; auditory brainstem responses (ABR), transient evoked otoacoustic emissions (TEOAE) and free field auditory responses (FF) for the prediction of permanent bilateral hearing loss in high-risk preterm infants at term post-conceptional age. A total of 51 preterm infants (gestational age < 34 weeks, birth weight < 1500 g) underwent examinations at term and hearing, speech and neurological development were followed up until a corrected age of 18 months. Significant hearing defects were verified by broader ABR examinations under sedation and by clinical ward observation including responsiveness to sounds and enhancement of hearing using an amplification device. Seven bilateral fails in ABR were found, together with nine bilateral fails in TEOAE and four fails in FF screening at term age. Six preterm infants were later confirmed to have a significant permanent bilateral hearing loss, four of whom had also cerebral palsy. Bilateral failure in ABR screening predicted hearing loss with a sensitivity of 100% and a specificity of 98%, TEOAE with a sensitivity of 50% and a specificity of 84% and in the FF examination at the levels of 50% and 98%, respectively. Transient evoked otoacoustic emissions alone seem not to be so applicable to the neonatal screening of hearing in high-risk preterm infants as shown earlier in full-term infants, possibly because a hearing defect may be due to retrocochlear damage. Consequently, auditory brainstem response screening seems to be more suitable for very low birth weight preterm infants.

  10. Abnormal ovarian cancer screening test result: women's informational, psychological and practical needs.

    PubMed

    Ryan, Patricia Y; Graves, Kristi D; Pavlik, Edward J; Andrykowski, Michael A

    2007-01-01

    Considerable effort has been devoted to the identification of cost-effective approaches to screening for ovarian cancer (OC). Transvaginal ultrasound (TVS) is one such screening approach. Approximately 5-7% of routine TVS screening tests yield abnormal results. Some women experience significant distress after receipt of an abnormal TVS screening test. Four focus groups provided in-depth, qualitative data regarding the informational, psychological, and practical needs of women after the receipt of an abnormal TVS result. Through question and content analytic procedures, we identified four themes: anticipation, emotional response, role of the screening technician, and impact of prior cancer experiences. Results provide initial guidance toward development of interventions to promote adaptive responses after receipt of an abnormal cancer screening test result.

  11. 40 CFR 86.427-78 - Emission tests.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 18 2010-07-01 2010-07-01 false Emission tests. 86.427-78 Section 86...) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES Emission Regulations for 1978 and Later New Motorcycles, General Provisions § 86.427-78 Emission tests. (a)(1) Each test vehicle shall be...

  12. Screening for Bladder and Other Urothelial Cancers

    MedlinePlus

    ... decrease the risk of dying from cancer. Scientists study screening tests to find those with the fewest risks and ... recovery . There is no standard or routine screening test for bladder cancer. Screening for bladder cancer is under study and there are screening clinical trials taking place ...

  13. An Alternative to Impedance Screening: Unoccluded Frontal Bone Conduction Screening.

    ERIC Educational Resources Information Center

    Square, Regina; And Others

    1985-01-01

    A bone conduction hearing screening test using frontal bone oscillator placement was compared with pure-tone air-conduction screening and impedance audiometry with 114 preschoolers. Unoccluded frontal bone conduction testing produced screening results not significantly different from results obtained by impedance audiometry. (CL)!

  14. Use of clinical movement screening tests to predict injury in sport

    PubMed Central

    Chimera, Nicole J; Warren, Meghan

    2016-01-01

    Clinical movement screening tests are gaining popularity as a means to determine injury risk and to implement training programs to prevent sport injury. While these screens are being used readily in the clinical field, it is only recently that some of these have started to gain attention from a research perspective. This limits applicability and poses questions to the validity, and in some cases the reliability, of the clinical movement tests as they relate to injury prediction, intervention, and prevention. This editorial will review the following clinical movement screening tests: Functional Movement Screen™, Star Excursion Balance Test, Y Balance Test, Drop Jump Screening Test, Landing Error Scoring System, and the Tuck Jump Analysis in regards to test administration, reliability, validity, factors that affect test performance, intervention programs, and usefulness for injury prediction. It is important to review the aforementioned factors for each of these clinical screening tests as this may help clinicians interpret the current body of literature. While each of these screening tests were developed by clinicians based on what appears to be clinical practice, this paper brings to light that this is a need for collaboration between clinicians and researchers to ensure validity of clinically meaningful tests so that they are used appropriately in future clinical practice. Further, this editorial may help to identify where the research is lacking and, thus, drive future research questions in regards to applicability and appropriateness of clinical movement screening tools. PMID:27114928

  15. Understanding type 2 diabetes mellitus screening practices among primary care physicians: a qualitative chart-stimulated recall study.

    PubMed

    Hafez, Dina; Nelson, Daniel B; Martin, Evan G; Cohen, Alicia J; Northway, Rebecca; Kullgren, Jeffrey T

    2017-04-04

    Early diagnosis and treatment of prediabetes and type 2 diabetes mellitus (T2DM) can prevent future health problems, yet many individuals with these conditions are undiagnosed. This could be due, in part, to primary care physicians' (PCP) screening practices, about which little is known. The objectives of this study were to identify factors that influence PCPs' decisions to screen patients for T2DM and to characterize their interpretation and communication of screening test results to patients. We conducted semi-structured chart-stimulated recall interviews with 20 University of Michigan Health System (UMHS) primary care physicians. PCPs were asked about their recent decisions to screen or not screen 134 purposively sampled non-diabetic patients who met American Diabetes Association criteria for screening for T2DM. Interviews were audio-recorded, transcribed, and analyzed using qualitative directed content analysis. Data on patient demographic characteristics and comorbidities were abstracted from the electronic health record. The most common reasons PCPs gave for not screening 63 patients for T2DM were knowledge of a previously normal screening test (49%) and a visit for reasons other than a health maintenance examination (48%). The most common reasons PCPs gave for screening 71 patients for T2DM were knowledge of a previously abnormal screening test (49%), and patients' weight (42%) and age (38%). PCPs correctly interpreted 89% of screening test results and communicated 95% of test results to patients. Among 24 patients found to have prediabetes, PCPs usually (58%) recommended weight loss and increased physical activity but never recommended participation in a Diabetes Prevention Program or use of metformin. Previous screening test results, visit types, and patients' weight and age influenced PCPs' decisions to screen for T2DM. When patients were screened, test results were generally correctly interpreted and consistently communicated. Recommendations to patients with prediabetes could better reflect evidence-based strategies to prevent T2DM.

  16. Testing a Spanish-language colorectal cancer screening decision aid in Latinos with limited English proficiency: results from a pre-post trial and four month follow-up survey.

    PubMed

    Reuland, Daniel S; Ko, Linda K; Fernandez, Alicia; Braswell, Laura C; Pignone, Michael

    2012-06-12

    Compared with non-Latinos, Latinos in the US have low rates of colorectal cancer (CRC) screening and low rates of knowledge regarding CRC screening tests and guidelines. Spanish speaking Latinos have particularly low CRC screening rates and screening knowledge. Our purpose was twofold: (1) to evaluate the effect of a computer-based, Spanish-language CRC screening decision aid on screening knowledge, intent to obtain screening, and screening self-efficacy in a community sample of Latinos with limited English proficiency (LEP); and (2) to survey these decision aid viewers at four months to determine their rates of CRC discussions with a health care provider as well as their rates of screening test completion. We recruited 50-75 year old Latinos with LEP who were not current with CRC. Participants screening viewed a 14 minute multimedia decision aid that addresses CRC screening rationale, recommendations, and options. We conducted an uncontrolled (pre-post) study in which we assessed screening knowledge, self-efficacy, and intent at baseline and immediately after decision aid viewing. We also conducted a follow-up telephone survey of participants at four months to examine rates of patient-provider screening discussions and test completion. Among n = 80 participants, knowledge scores increased from 20% (before) to 72% (after) decision aid viewing (absolute difference [95%CI]: 52% [46, 59]). The proportion with high screening self-efficacy increased from 67% to 92% (25% [13, 37]); the proportion with high screening intent increased from 63% to 95% (32% [21, 44]). We reached 68 (85%) of 80 participants eligible for the follow-up survey. Of these 36 (53%) reported discussing screening with a provider and 13 (19%) completed a test. Viewing a Spanish-language decision aid increased CRC screening knowledge, self-efficacy, and intent among Latinos with LEP. Decision aid viewing appeared to promote both CRC screening discussions with health care providers and test completion. The decision aid may be an effective tool for promoting CRC screening and reducing screening disparities in this population.

  17. Health Screening

    MedlinePlus

    Screenings are tests that look for diseases before you have symptoms. Screening tests can find diseases early, when they're easier ... Overweight and obesity Prostate cancer in men Which tests you need depends on your age, your sex, ...

  18. Colorectal Cancer Screening

    MedlinePlus

    ... blood test Sigmoidoscopy Colonoscopy Virtual colonoscopy DNA stool test Studies have shown that screening for colorectal cancer using ... decrease the risk of dying from cancer. Scientists study screening tests to find those with the fewest risks and ...

  19. What Screening Tests Are There?

    MedlinePlus

    ... Women” Stay Informed Cancer Home What Screening Tests Are There? Language: English (US) Español (Spanish) Recommend on ... Screening means testing for a disease when there are no symptoms or history of that disease. Doctors ...

  20. HPV testing for cervical cancer screening appears more cost-effective than Papanicolau cytology in Mexico.

    PubMed

    Flores, Yvonne N; Bishai, David M; Lorincz, Attila; Shah, Keerti V; Lazcano-Ponce, Eduardo; Hernández, Mauricio; Granados-García, Víctor; Pérez, Ruth; Salmerón, Jorge

    2011-02-01

    To determine the incremental costs and effects of different HPV testing strategies, when compared to Papanicolau cytology (Pap), for cervical cancer screening in Mexico. A cost-effectiveness analysis (CEA) examined the specific costs and health outcomes associated with (1) no screening; (2) only the Pap test; (3) only self-administered HPV; (4) only clinician administered HPV; and (5) clinician administered HPV plus the Pap test. The costs of self- and clinician-HPV testing, as well as with the Pap test, were identified and quantified. Costs were reported in 2008 US dollars. The health outcome associated with these screening strategies was defined as the number of high-grade cervical intraepithelial neoplasia or cervical cancer cases detected. This CEA was performed using the perspective of the Mexican Institute of Social Security (IMSS) in Morelos, Mexico. Screening women between the ages of 30-80 for cervical cancer using clinical-HPV testing or the combination of clinical-HPV testing, and the Pap is always more cost-effective than using the Pap test alone. This CEA indicates that HPV testing could be a cost-effective screening alternative for a large health delivery organization such as IMSS. These results may help policy-makers implement HPV testing as part of the IMSS cervical cancer screening program.

  1. HPV testing for cervical cancer screening appears more cost-effective than Papanicolau cytology in Mexico

    PubMed Central

    Bishai, David M.; Lőrincz, Attila; Shah, Keerti V.; Lazcano-Ponce, Eduardo; Hernández, Mauricio; Granados-García, Víctor; Pérez, Ruth; Salmerón, Jorge

    2010-01-01

    Objective To determine the incremental costs and effects of different HPV testing strategies, when compared to Papanicolau cytology (Pap), for cervical cancer screening in Mexico. Methods A cost-effectiveness analysis (CEA) examined the specific costs and health outcomes associated with (1) no screening; (2) only the Pap test; (3) only self-administered HPV; (4) only clinician administered HPV; and (5) clinician administered HPV plus the Pap test. The costs of self- and clinician-HPV testing, as well as with the Pap test, were identified and quantified. Costs were reported in 2008 US dollars. The health outcome associated with these screening strategies was defined as the number of high-grade cervical intraepithelial neoplasia or cervical cancer cases detected. This CEA was performed using the perspective of the Mexican Institute of Social Security (IMSS) in Morelos, Mexico. Results Screening women between the ages of 30–80 for cervical cancer using clinical-HPV testing or the combination of clinical-HPV testing, and the Pap is always more cost-effective than using the Pap test alone. Conclusions This CEA indicates that HPV testing could be a cost-effective screening alternative for a large health delivery organization such as IMSS. These results may help policy-makers implement HPV testing as part of the IMSS cervical cancer screening program. PMID:21170578

  2. Mercury ion thruster research, 1978

    NASA Technical Reports Server (NTRS)

    Wilbur, P. J.

    1978-01-01

    The effects of 8 cm thruster main and neutralizer cathode operating conditions on cathode orifice plate temperatures were studied. The effects of cathode operating conditions on insert temperature profiles and keeper voltages are presented for three different types of inserts. The bulk of the emission current is generally observed to come from the downstream end of the insert rather than from the cathode orifice plate. Results of a test in which the screen grid plasma sheath of a thruster was probed as the beam current was varied are shown. Grid performance obtained with a grid machined from glass ceramic is discussed. The effects of copper and nitrogen impurities on the sputtering rates of thruster materials are measured experimentally and a model describing the rate of nitrogen chemisorption on materials in either the beam or the discharge chamber is presented. The results of optimization of a radial field thruster design are presented. Performance of this device is shown to be comparable to that of a divergent field thruster and efficient operation with the screen grid biased to floating potential, where its susceptibility to sputter erosion damage is reduced, is demonstrated.

  3. Biomarkers in the Diagnosis and Prognosis of Alzheimer's Disease.

    PubMed

    Schaffer, Cole; Sarad, Nakia; DeCrumpe, Ashton; Goswami, Disha; Herrmann, Sara; Morales, Jose; Patel, Parth; Osborne, Jim

    2015-10-01

    Alzheimer's disease (AD) is a neurodegenerative disease that inhibits cognitive functions and has no cure. This report reviews the current diagnostic standards for AD with an emphasis on early diagnosis using the cerebrospinal fluid (CSF) biomarkers amyloid-beta, t-tau, and p-tau and fluorodeoxyglucose positron emission tomography imaging. Abnormal levels of these CSF biomarkers and decreased cerebral uptake of glucose have recently been used in the early diagnosis of AD in experimental studies. These promising biomarkers can be measured using immunoassays performed in singleplex or multiplex formats. Although presently, there are no Food and Drug Administration-approved in vitro diagnostics (IVDs) for early detection of AD, a multiplex immunoassay measuring a panel of promising AD biomarkers in CSF may be a likely IVD candidate for the clinical AD diagnostic market. Specifically, the INNO-BIA AlzBio3 immunoassay kit, performed using bead arrays on the xMAP Luminex analyzer, allows simultaneous quantification of amyloid-beta, t-tau, and p-tau biomarkers. AD biomarkers can also be screened using enzyme-linked immunosorbent assays that are offered as laboratory-developed tests. © 2014 Society for Laboratory Automation and Screening.

  4. ROC and Loss Function Analysis in Sequential Testing

    ERIC Educational Resources Information Center

    Muijtjens, Arno M. M.; Van Luijk, Scheltus J.; Van Der Vleuten, Cees P. M.

    2006-01-01

    Sequential testing is applied to reduce costs in SP-based tests (OSCEs). Initially, all candidates take a screening test consisting of a part of the OSCE. Candidates who fail the screen sit the complete test, whereas those who pass the screen are qualified as a pass of the complete test. The procedure may result in a reduction of testing…

  5. Implementation and process evaluation of a workplace colorectal cancer screening program in eastern Washington.

    PubMed

    Hannon, Peggy A; Vu, Thuy; Ogdon, Sara; Fleury, Emily M; Yette, Emily; Wittenberg, Reva; Celedonia, Megan; Bowen, Deborah J

    2013-03-01

    Colorectal cancer screening is a life-saving intervention, but screening rates are low. The authors implemented and evaluated the Spokane Colorectal Cancer Screening Program-a novel worksite intervention to promote colorectal cancer screening that used a combination of evidence-based strategies recommended by the Guide to Community Preventive Services, as well as additional strategies. Over a period of approximately 3 months, participating worksites held one or more physician-led seminars about colorectal cancer screening for employees. They also distributed free fecal immunochemical tests at the worksite to employees 50 years and older, and they provided test results to employees and their primary care physician. The authors measured attendance at seminars, test kits taken and returned, employee awareness of the program, and colorectal cancer screening rates in participating and comparison worksites. It is estimated that 9% of eligible employees received kits at the worksite, and 4% were screened with these kits. The Spokane Colorectal Cancer Screening Program was a promising pilot test of an innovative worksite screening program that successfully translated evidence-based strategies into practical use in a brief period of time, and it merits a larger study to be able to test its effects more rigorously.

  6. Calculation of the X-Ray emission K and L 2,3 bands of metallic magnesium and aluminum with allowance for multielectron effects

    NASA Astrophysics Data System (ADS)

    Ovcharenko, R. E.; Tupitsyn, I. I.; Savinov, E. P.; Voloshina, E. N.; Dedkov, Yu. S.; Shulakov, A. S.

    2014-01-01

    A procedure is proposed to calculate the shape of the characteristic X-ray emission bands of metals with allowance for multielectron effects. The effects of the dynamic screening of a core vacancy by conduction electrons and the Auger effect in the valence band are taken into account. The dynamic screening of a core vacancy, which is known to be called the MND (Mahan-Nozeieres-De Dominics) effect, is taken into account by an ab initio band calculation of crystals using the PAW (projected augmented waves) method. The Auger effect is taken into account by a semiempirical method using the approximation of a quadratic dependence of the level width in the valence band on the difference between the level energy and the Fermi energy. The proposed calculation procedure is used to describe the X-ray emission K and L 2,3 bands of metallic magnesium and aluminum crystals. The calculated spectra agree well with the experimental bands both near the Fermi level and in the low-energy part of the spectra in all cases.

  7. A new continuous fluorometric assay for acetylcholinesterase activity and inhibitor screening with emissive core-shell silica particles containing tetraphenylethylene fluorophore.

    PubMed

    Shen, Xiang; Liang, Fuxin; Zhang, Guanxin; Zhang, Deqing

    2012-05-07

    Emissive core-shell silica particles with tetraphenylethylene moieties were prepared and characterized. Fluorescence quenching was observed for the silica particles upon addition of compound 2 (Dabcyl-ACh). This was attributed to the electrostatic interaction between the silica particles and 2 and the resulting photoinduced energy transfer between them. After incubation with AChE, the fluorescence intensity started to increase. The fluorescence enhancement became more significant when the concentration of AChE was higher. The reaction kinetic parameters for AChE were successfully estimated with the silica particles and 2. These results reveal that the ensemble of the silica particles and 2 can be utilized for AChE assay. Moreover, the fluorescence spectra of the ensemble of the silica particles and 2 containing AChE were also measured after further addition of either neostigmine or tacrine which are typical inhibitors of AChE. The results manifest that the ensemble of the emissive silica particles and 2 is also useful for screening the inhibitors of AChE.

  8. LETTER TO THE EDITOR: Green emission and bandgap narrowing due to two-photon excitation in thin film CdS formed by spray pyrolysis

    NASA Astrophysics Data System (ADS)

    Ullrich, B.; Schroeder, R.

    2001-08-01

    Thin (10 µm) film CdS on Pyrex® formed by spray pyrolysis is excited below the gap at 804 nm with 200 fs laser pulses at room temperature. Excitation intensities up to 250 GW cm-2 evoke green bandgap emission due to two-photon transitions. This two-photon photoluminescence does not show a red emission contribution in contrast to the single-photon excited emission, which is dominated by broad emission in the red spectral range. It is demonstrated that two-photon excitation causes photo-induced bandgap narrowing due to Debye screening. At 250 GW cm-2 bandgap narrowing of 47 meV is observed, which corresponds to an excited electron density of 1.6×1018 cm-3.

  9. 40 CFR 86.427-78 - Emission tests.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 19 2012-07-01 2012-07-01 false Emission tests. 86.427-78 Section 86... Later New Motorcycles, General Provisions § 86.427-78 Emission tests. (a)(1) Each test vehicle shall be driven with all emission control systems installed and operating for the following total test distances...

  10. 40 CFR 86.427-78 - Emission tests.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 19 2014-07-01 2014-07-01 false Emission tests. 86.427-78 Section 86... Later New Motorcycles, General Provisions § 86.427-78 Emission tests. (a)(1) Each test vehicle shall be driven with all emission control systems installed and operating for the following total test distances...

  11. 40 CFR 86.427-78 - Emission tests.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 19 2013-07-01 2013-07-01 false Emission tests. 86.427-78 Section 86... Later New Motorcycles, General Provisions § 86.427-78 Emission tests. (a)(1) Each test vehicle shall be driven with all emission control systems installed and operating for the following total test distances...

  12. The Clock Drawing Test versus Mini-mental Status Examination as a Screening Tool for Dementia: A Clinical Comparison

    PubMed Central

    Palsetia, Delnaz; Rao, G. Prasad; Tiwari, Sarvada C.; Lodha, Pragya; De Sousa, Avinash

    2018-01-01

    There is a growing incidence of dementia patients in the community, and with this growth, there is need for rapid, valid, and easily administrable tests for the screening of dementia and mild cognitive impairment in the community. This review looks at the two most commonly used tests in dementia screening, namely, the clock drawing test (CDT) and the mini-mental status examination (MMSE). Both these tests have been used in dementia screening over the past three decades and have been the subject of scrutiny of various studies, reviews, and meta-analysis. Both these tests are analyzed on their ability to assess dementia and screen for it in the community, general practice and general hospital settings. The methods of administration and scoring of each test are discussed, and their advantages and disadvantages are explained. There is also a direct comparison made between the MMSE and CDT in dementia screening. Future research needs with these tests are also elucidated. PMID:29403122

  13. Validity of screening tests for Sjögren's syndrome in ambulatory patients with chronic diseases.

    PubMed

    Sánchez-Guerrero, Jorge; Pérez-Dosal, Marcia R; Celis-Aguilar, Erika; Cárdenas-Velázquez, Francisco; Soto-Rojas, Armando E; Avila-Casado, Carmen

    2006-05-01

    To determine the validity of screening tests for Sjogren's syndrome (SS) in ambulatory patients with chronic diseases. Three hundred randomly selected patients from the rheumatology and internal medicine clinics of a tertiary care center were assessed for SS according to the American-European Consensus Group criteria. During the screening phase, an interview, the European questionnaire for sicca symptoms, Schirmer-I test, and the wafer test were carried out in all patients. Patients with positive screening had confirmatory tests including fluorescein staining test, nonstimulated whole salivary flow, and autoantibody testing. Confirmatory tests were also done in 13 patients with negative screening. During the last phase, lip biopsy was proposed to patients who met preestablished criteria. Women made up 79% of the study population. Mean age of subjects was 42.8+/-15.7 years. Two hundred twenty patients (73%) had positive screening. The distribution of positive test results was: xerophthalmia 118 (39%), xerostomia 103 (34%), Schirmer-I test 101 (34%), and wafer test 187 (62%) patients. Forty (13%) patients met criteria for SS. All screening tests were useful for identifying patients with SS; however, the model composed of at least one positive response to the European questionnaire (EQ1), Schirmer-I test, and wafer test showed the best performance. Use of the European questionnaire, Schirmer-I test, and wafer test in parallel was useful for identifying patients with SS among ambulatory patients with chronic diseases.

  14. Cost-Effectiveness of Cervical Cancer Screening With Human Papillomavirus DNA Testing and HPV-16,18 Vaccination

    PubMed Central

    Goldhaber-Fiebert, Jeremy D.; Stout, Natasha K.; Salomon, Joshua A.; Kuntz, Karen M.; Goldie, Sue J.

    2011-01-01

    Background The availability of human papillomavirus (HPV) DNA testing and vaccination against HPV types 16 and 18 (HPV-16,18) motivates questions about the cost-effectiveness of cervical cancer prevention in the United States for unvaccinated older women and for girls eligible for vaccination. Methods An empirically calibrated model was used to assess the quality-adjusted life years (QALYs), lifetime costs, and incremental cost-effectiveness ratios (2004 US dollars per QALY) of screening, vaccination of preadolescent girls, and vaccination combined with screening. Screening varied by initiation age (18, 21, or 25 years), interval (every 1, 2, 3, or 5 years), and test (HPV DNA testing of cervical specimens or cytologic evaluation of cervical cells with a Pap test). Testing strategies included: 1) cytology followed by HPV DNA testing for equivocal cytologic results (cytology with HPV test triage); 2) HPV DNA testing followed by cytology for positive HPV DNA results (HPV test with cytology triage); and 3) combined HPV DNA testing and cytology. Strategies were permitted to switch once at age 25, 30, or 35 years. Results For unvaccinated women, triennial cytology with HPV test triage, beginning by age 21 years and switching to HPV testing with cytology triage at age 30 years, cost $78 000 per QALY compared with the next best strategy. For girls vaccinated before age 12 years, this same strategy, beginning at age 25 years and switching at age 35 years, cost $41 000 per QALY with screening every 5 years and $188 000 per QALY screening triennially, each compared with the next best strategy. These strategies were more effective and cost-effective than screening women of all ages with cytology alone or cytology with HPV triage annually or biennially. Conclusions For both vaccinated and unvaccinated women, age-based screening by use of HPV DNA testing as a triage test for equivocal results in younger women and as a primary screening test in older women is expected to be more cost-effective than current screening recommendations. PMID:18314477

  15. Tests Screening Reading Difficulty in Malayalam among Upper Primary School Boys

    ERIC Educational Resources Information Center

    Gafoor, K. Abdul

    2014-01-01

    Design of a screening test for identifying reading difficult students in Malayalam and validation thereof among boys is made to help schools proactively intervene with such students. A battery of tests developed based on extant literature on screening tests, reviewed difficulties in reading Malayalam, and discrimination power of the draft tests is…

  16. Risks of Colorectal Cancer Screening

    MedlinePlus

    ... blood test Sigmoidoscopy Colonoscopy Virtual colonoscopy DNA stool test Studies have shown that screening for colorectal cancer using ... decrease the risk of dying from cancer. Scientists study screening tests to find those with the fewest risks and ...

  17. A Pilot Study of Children's Blood Lead Levels in Mount Isa, Queensland.

    PubMed

    Green, Donna; Sullivan, Marianne; Cooper, Nathan; Dean, Annika; Marquez, Cielo

    2017-12-13

    Mount Isa, Queensland, is one of three Australian cities with significant lead emissions due to nonferrous mining and smelting. Unlike the two other cities with lead mines or smelters, Mount Isa currently has no system of annual, systematic, community-wide blood lead level testing; and testing rates among Indigenous children are low. In previous screenings, this group of children has been shown to have higher average blood lead levels than non-Indigenous children. The first aim of this study was to assess whether parents and children would participate in less invasive, rapid point-of-care capillary testing. The second aim was to measure blood lead levels among a range of children that roughly reflected the percentage of the Indigenous/non-Indigenous population. This pilot study is based on a convenience sample of children between the ages of 12 and 83 months who were recruited to participate by staff at a Children and Family Centre. Over three half-days, 30 children were tested using capillary blood samples and the LeadCare II Point-of-Care testing system. Rapid point-of-care capillary testing was well tolerated by the children. Of 30 children tested, 40% ( n = 12) had blood lead levels ≥5 µg/dL and 10% had levels ≥10 µg/dL. The highest blood lead level measured was 17.3 µg/dL. The percentage of children with blood lead levels ≥5 µg/dL was higher among Indigenous children compared to non-Indigenous (64.2% compared to 18.8%) as was the geometric mean level (6.5 (95% CI, 4.7, 9.2) versus 2.4 (95% CI, 1.8, 3.1)), a statistically significant difference. Though based on a small convenience sample, this study identified 12 children (40%) of the sample with blood lead levels ≥5 µg/dL. Due to historical and ongoing heavy metal emissions from mining and smelting in Mount Isa, we recommend a multi-component program of universal blood lead level testing, culturally appropriate follow-up and intervention for children who are identified with blood lead levels ≥5 µg/dL. We further recommend focused outreach and assistance to the Indigenous community, and further control of emissions and remediation of existing environmental lead contamination in children's play and residential areas.

  18. Colorectal Cancer Screening: Recommendations for Physicians and Patients From the U.S. Multi-Society Task Force on Colorectal Cancer.

    PubMed

    Rex, Douglas K; Boland, C Richard; Dominitz, Jason A; Giardiello, Francis M; Johnson, David A; Kaltenbach, Tonya; Levin, Theodore R; Lieberman, David; Robertson, Douglas J

    2017-07-01

    This document updates the colorectal cancer (CRC) screening recommendations of the U.S. Multi-Society Task Force of Colorectal Cancer (MSTF), which represents the American College of Gastroenterology, the American Gastroenterological Association, and The American Society for Gastrointestinal Endoscopy. CRC screening tests are ranked in 3 tiers based on performance features, costs, and practical considerations. The first-tier tests are colonoscopy every 10 years and annual fecal immunochemical test (FIT). Colonoscopy and FIT are recommended as the cornerstones of screening regardless of how screening is offered. Thus, in a sequential approach based on colonoscopy offered first, FIT should be offered to patients who decline colonoscopy. Colonoscopy and FIT are recommended as tests of choice when multiple options are presented as alternatives. A risk-stratified approach is also appropriate, with FIT screening in populations with an estimated low prevalence of advanced neoplasia and colonoscopy screening in high prevalence populations. The second-tier tests include CT colonography every 5 years, the FIT-fecal DNA test every 3 years, and flexible sigmoidoscopy every 5 to 10 years. These tests are appropriate screening tests, but each has disadvantages relative to the tier 1 tests. Because of limited evidence and current obstacles to use, capsule colonoscopy every 5 years is a third-tier test. We suggest that the Septin9 serum assay (Epigenomics, Seattle, Wash) not be used for screening. Screening should begin at age 50 years in average-risk persons, except in African Americans in whom limited evidence supports screening at 45 years. CRC incidence is rising in persons under age 50, and thorough diagnostic evaluation of young persons with suspected colorectal bleeding is recommended. Discontinuation of screening should be considered when persons up to date with screening, who have prior negative screening (particularly colonoscopy), reach age 75 or have <10 years of life expectancy. Persons without prior screening should be considered for screening up to age 85, depending on age and comorbidities. Persons with a family history of CRC or a documented advanced adenoma in a first-degree relative age <60 years or 2 first-degree relatives with these findings at any age are recommended to undergo screening by colonoscopy every 5 years, beginning 10 years before the age at diagnosis of the youngest affected relative or age 40, whichever is earlier. Persons with a single first-degree relative diagnosed at ≥60 years with CRC or an advanced adenoma can be offered average-risk screening options beginning at age 40 years. Copyright © 2017 AGA Institute, American College of Gastroenterology, and the American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  19. Zagreb Amblyopia Preschool Screening Study: near and distance visual acuity testing increase the diagnostic accuracy of screening for amblyopia.

    PubMed

    Bušić, Mladen; Bjeloš, Mirjana; Petrovečki, Mladen; Kuzmanović Elabjer, Biljana; Bosnar, Damir; Ramić, Senad; Miletić, Daliborka; Andrijašević, Lidija; Kondža Krstonijević, Edita; Jakovljević, Vid; Bišćan Tvrdi, Ana; Predović, Jurica; Kokot, Antonio; Bišćan, Filip; Kovačević Ljubić, Mirna; Motušić Aras, Ranka

    2016-02-01

    To present and evaluate a new screening protocol for amblyopia in preschool children. Zagreb Amblyopia Preschool Screening (ZAPS) study protocol performed screening for amblyopia by near and distance visual acuity (VA) testing of 15 648 children aged 48-54 months attending kindergartens in the City of Zagreb County between September 2011 and June 2014 using Lea Symbols in lines test. If VA in either eye was >0.1 logMAR, the child was re-tested, if failed at re-test, the child was referred to comprehensive eye examination at the Eye Clinic. 78.04% of children passed the screening test. Estimated prevalence of amblyopia was 8.08%. Testability, sensitivity, and specificity of the ZAPS study protocol were 99.19%, 100.00%, and 96.68% respectively. The ZAPS study used the most discriminative VA test with optotypes in line as they do not underestimate amblyopia. The estimated prevalence of amblyopia was considerably higher than reported elsewhere. To the best of our knowledge, the ZAPS study protocol reached the highest sensitivity and specificity when evaluating diagnostic accuracy of VA tests for screening. The pass level defined at ≤0.1 logMAR for 4-year-old children, using Lea Symbols in lines missed no amblyopia cases, advocating that both near and distance VA testing should be performed when screening for amblyopia.

  20. Zagreb Amblyopia Preschool Screening Study: near and distance visual acuity testing increase the diagnostic accuracy of screening for amblyopia

    PubMed Central

    Bušić, Mladen; Bjeloš, Mirjana; Petrovečki, Mladen; Kuzmanović Elabjer, Biljana; Bosnar, Damir; Ramić, Senad; Miletić, Daliborka; Andrijašević, Lidija; Kondža Krstonijević, Edita; Jakovljević, Vid; Bišćan Tvrdi, Ana; Predović, Jurica; Kokot, Antonio; Bišćan, Filip; Kovačević Ljubić, Mirna; Motušić Aras, Ranka

    2016-01-01

    Aim To present and evaluate a new screening protocol for amblyopia in preschool children. Methods Zagreb Amblyopia Preschool Screening (ZAPS) study protocol performed screening for amblyopia by near and distance visual acuity (VA) testing of 15 648 children aged 48-54 months attending kindergartens in the City of Zagreb County between September 2011 and June 2014 using Lea Symbols in lines test. If VA in either eye was >0.1 logMAR, the child was re-tested, if failed at re-test, the child was referred to comprehensive eye examination at the Eye Clinic. Results 78.04% of children passed the screening test. Estimated prevalence of amblyopia was 8.08%. Testability, sensitivity, and specificity of the ZAPS study protocol were 99.19%, 100.00%, and 96.68% respectively. Conclusion The ZAPS study used the most discriminative VA test with optotypes in lines as they do not underestimate amblyopia. The estimated prevalence of amblyopia was considerably higher than reported elsewhere. To the best of our knowledge, the ZAPS study protocol reached the highest sensitivity and specificity when evaluating diagnostic accuracy of VA tests for screening. The pass level defined at ≤0.1 logMAR for 4-year-old children, using Lea Symbols in lines missed no amblyopia cases, advocating that both near and distance VA testing should be performed when screening for amblyopia. PMID:26935612

  1. Clinicians' perceptions of the benefits and harms of prostate and colorectal cancer screening.

    PubMed

    Elstad, Emily A; Sutkowi-Hemstreet, Anne; Sheridan, Stacey L; Vu, Maihan; Harris, Russell; Reyna, Valerie F; Rini, Christine; Earp, Jo Anne; Brewer, Noel T

    2015-05-01

    Clinicians' perceptions of screening benefits and harms influence their recommendations, which in turn shape patients' screening decisions. We sought to understand clinicians' perceptions of the benefits and harms of cancer screening by comparing 2 screening tests that differ in their balance of potential benefits to harms: colonoscopy, which results in net benefit for many adults, and prostate-specific antigen (PSA) testing, which may do more harm than good. In this cross-sectional study, 126 clinicians at 24 family/internal medicine practices completed surveys in which they listed and rated the magnitude of colonoscopy and PSA testing benefits and harms for a hypothetical 70-year-old male patient and then estimated the likelihood that these tests would cause harm and lengthen the life of 100 similar men in the next 10 years. We tested the hypothesis that the availability heuristic would explain the association of screening test to perceived likelihood of benefit/harm and a competing hypothesis that clinicians' gist of screening tests as good or bad would mediate this association. Clinicians perceived PSA testing to have a greater likelihood of harm and a lower likelihood of lengthening life relative to colonoscopy. Consistent with our gist hypothesis, these associations were mediated by clinicians' gist of screening (balance of perceived benefits to perceived harms). Generalizability beyond academic clinicians remains to be established. Targeting clinicians' gist of screening, for example through graphical displays that allow clinicians to make gist-based relative magnitude comparisons, may influence their risk perception and possibly reduce overrecommendation of screening. © The Author(s) 2015.

  2. A framework provided an outline toward the proper evaluation of potential screening strategies.

    PubMed

    Adriaensen, Wim J; Matheï, Cathy; Buntinx, Frank J; Arbyn, Marc

    2013-06-01

    Screening tests are often introduced into clinical practice without proper evaluation, despite the increasing awareness that screening is a double-edged sword that can lead to either net benefits or harms. Our objective was to develop a comprehensive framework for the evaluation of new screening strategies. Elaborating on the existing concepts proposed by experts, a stepwise framework is proposed to evaluate whether a potential screening test can be introduced as a screening strategy into clinical practice. The principle of screening strategy evaluation is illustrated for cervical cancer, which is a template for screening because of the existence of an easily detectable and treatable precursor lesion. The evaluation procedure consists of six consecutive steps. In steps 1-4, the technical accuracy, place of the test in the screening pathway, diagnostic accuracy, and longitudinal sensitivity and specificity of the screening test are assessed. In steps 5 and 6, the impact of the screening strategy on the patient and population levels, respectively, is evaluated. The framework incorporates a harm and benefit trade-off and cost-effectiveness analysis. Our framework provides an outline toward the proper evaluation of potential screening strategies before considering implementation. Copyright © 2013 Elsevier Inc. All rights reserved.

  3. Knowledge and practice of iranians toward colorectal cancer, and barriers to screening.

    PubMed

    Salimzadeh, Hamideh; Delavari, Alireza; Montazeri, Ali; Mirzazadeh, Ali

    2012-01-01

    Colorectal cancer (CRC) is the third most common malignancy in Iran. Limited data are available on knowledge and barriers in regard to CRC and screening tests in Iran. The aim of the study was to characterize knowledge, practice, and barriers toward CRC and its screening tests among an Iranian at-risk population. This cross-sectional study was conducted with participation of 200 individuals of both genders aged 50 years or older in a teaching hospital in Tehran, Iran. Data were collected via face-to-face interviews. A questionnaire containing demographics; knowledge about CRC and screening tests; screening practice; and reasons for not being screened was administered. The reliability alpha for knowledge items was 0.52. The age of the participants ranged from 50 to 83 years (mean 60.13). Overall, 11% of the respondents reported prior screening by either fecal occult blood test (6.5%) or colonoscopy (4.5%). The majority of individuals had poor knowledge although respondents with prior screening obtained slightly higher score in comparison with nonparticipants in screening (26.74 vs. 23.24; P<0.05). Four commonly cited reasons for not having CRC tests were "doctor did not recommend the test," "did not think it was needed," "never think of the test," and "no symptoms/problems" which were reported by 29%, 26%, 20%, and 17% of the participants, respectively. It is necessary to design appropriate educational interventions to increase the general population's knowledge about CRC and screening before implementing preventive programs in Iran.

  4. PM4 crystalline silica emission factors and ambient concentrations at aggregate-producing sources in California.

    PubMed

    Richards, John R; Brozell, Todd T; Rea, Charles; Boraston, Geoff; Hayden, John

    2009-11-01

    The California Construction and Industrial Minerals Association and the National Stone, Sand, & Gravel Association have sponsored tests at three sand and gravel plants in California to compile crystalline silica emission factors for particulate matter (PM) of aerodynamic diameter of 4 microm or less (PM4) and ambient concentration data. This information is needed by industrial facilities to evaluate compliance with the Chronic Reference Exposure Level (REL) for ambient crystalline silica adopted in 2005 by the California Office of Environmental Health Hazard Assessment. The REL applies to PM4 respirable PM. Air Control Techniques, P.C. sampled for PM4 crystalline silica using a conventional sampler for PM of aerodynamic diameter of 2.5 microm or less (PM2.5), which met the requirements of 40 Code of Federal Regulations Part 50, Appendix L. The sample flow rate was adjusted to modify the 50% cut size to 4 microm instead of 2.5 microm. The filter was also changed to allow for crystalline silica analyses using National Institute for Occupational Safety and Health (NIOSH) Method 7500. The particle size-capture efficiency curve for the modified Appendix L instrument closely matched the performance curve of NIOSH Method 0600 for PM4 crystalline silica and provided a minimum detection limit well below the levels attainable with NIOSH Method 0600. The results of the tests indicate that PM4 crystalline silica emissions range from 0.000006 to 0.000110 lb/t for screening operations, tertiary crushers, and conveyor transfer points. The PM4 crystalline silica emission factors were proportional to the crystalline silica content of the material handled in the process equipment. Measured ambient concentrations ranged from 0 (below detectable limit) to 2.8 microg/m3. All values measured above 2 microg/m3 were at locations upwind of the facilities being tested. The ambient PM4 crystalline silica concentrations measured during this study were below the California REL of 3 microg/m3. The measured ambient concentrations in the PM4 size range are consistent with previously published ambient crystalline silica data applicable to the PM2.5 and PM of aerodynamic diameter of 10 microm or less (PM10) size ranges.

  5. Cervical Cancer Screening in Low-Resource Settings: A Cost-Effectiveness Framework for Valuing Tradeoffs between Test Performance and Program Coverage

    PubMed Central

    Campos, Nicole G.; Castle, Philip E.; Wright, Thomas C.; Kim, Jane J.

    2016-01-01

    As cervical cancer screening programs are implemented in low-resource settings, protocols are needed to maximize health benefits under operational constraints. Our objective was to develop a framework for examining health and economic tradeoffs between screening test sensitivity, population coverage, and follow-up of screen-positive women, to help decision makers identify where program investments yield the greatest value. As an illustrative example, we used an individual-based Monte Carlo simulation model of the natural history of human papillomavirus (HPV) and cervical cancer calibrated to epidemiologic data from Uganda. We assumed once in a lifetime screening at age 35 with two-visit HPV DNA testing or one-visit visual inspection with acetic acid (VIA). We assessed the health and economic tradeoffs that arise between 1) test sensitivity and screening coverage; 2) test sensitivity and loss to follow-up (LTFU) of screen-positive women; and 3) test sensitivity, screening coverage, and LTFU simultaneously. The decline in health benefits associated with sacrificing HPV DNA test sensitivity by 20% (e.g., shifting from provider- to self-collection of specimens) could be offset by gains in coverage if coverage increased by at least 20%. When LTFU was 10%, two-visit HPV DNA testing with 80-90% sensitivity was more effective and more cost-effective than one-visit VIA with 40% sensitivity, and yielded greater health benefits than VIA even as VIA sensitivity increased to 60% and HPV test sensitivity declined to 70%. As LTFU increased, two-visit HPV DNA testing became more costly and less effective than one-visit VIA. Setting-specific data on achievable test sensitivity, coverage, follow-up rates, and programmatic costs are needed to guide programmatic decision making for cervical cancer screening. PMID:25943074

  6. Comparisons between vehicular emissions from real-world in-use testing and EPA moves estimation.

    DOT National Transportation Integrated Search

    2012-07-01

    "This research study developed a methodology to perform mandatory dynamometer vehicular emissions tests : on real roads, performed on-road emissions tests, and compared the test results to the estimates using the : current EPA emissions estimation mo...

  7. Comparing the field and laboratory emission cell (FLEC) with traditional emissions testing chambers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Roache, N.F.; Guo, Z.; Fortmann, R.

    1996-12-31

    A series of tests was designed to evaluate the performance of the field and laboratory emission cell (FLEC) as applied to the testing of emissions from two indoor coating materials, floor wax and latex paint. These tests included validation of the repeatability of the test method, evaluation of the effect of different air velocities on source emissions, and a comparison of FLEC versus small chamber characterization of emissions. The FLEC exhibited good repeatability in characterization of emissions when applied to both sources under identical conditions. Tests with different air velocities showed significant effects on the emissions from latex paint, yetmore » little effect on emissions from the floor wax. Comparisons of data from the FLEC and small chamber show good correlation for measurements involving floor wax, but less favorable results for emissions from latex paint. The procedures and findings are discussed; conclusions are limited and include emphasis on the need for additional study and development of a standard method.« less

  8. A comparative review of developmental screening tests.

    PubMed

    Glascoe, F P; Martin, E D; Humphrey, S

    1990-10-01

    Public Law 99-457 amends the Education of the Handicapped Act to include services for children from birth through 3 years. Inasmuch as detection and referral of children with developmental delays continues to reside largely with pediatricians and other health care professionals, developmental screening, using standardized tests, is increasingly important. To help physicians select from the array of instruments, 19 different screening tests were administered by a pediatrician and rated by a panel of pediatricians and a special educator. While the panel found few tests that fit within the time constraints of pediatric practice, several tests approached standards for educational and psychologic tests. These included the Battelle Developmental Inventory Screening Test, Infant Monitoring System, Developmental Indicators for Assessment of Learning-Revised, Screening Children for Related Early Educational Needs, and the Developmental Profile II.

  9. Real-time Stack Monitoring at the BaTek Medical Isotope Production Facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McIntyre, Justin I.; Agusbudiman, A.; Cameron, Ian M.

    2016-04-01

    Radioxenon emissions from radiopharmaceutical production are a major source of background concentrations affecting the radioxenon detection systems of the International Monitoring System (IMS). Collection of real-time emissions data from production facilities makes it possible to screen out some medical isotope signatures from the IMS radioxenon data sets. This paper describes an effort to obtain and analyze real-time stack emissions data with the design, construction and installation of a small stack monitoring system developed by a joint CTBTO-IDC, BATAN, and PNNL team at the BaTek medical isotope production facility near Jakarta, Indonesia.

  10. 40 CFR 1060.235 - What emission testing must I perform for my application for a certificate of conformity?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 34 2013-07-01 2013-07-01 false What emission testing must I perform... emission testing must I perform for my application for a certificate of conformity? This section describes the emission testing you must perform to show compliance with the emission standards in subpart B of...

  11. 40 CFR 1060.235 - What emission testing must I perform for my application for a certificate of conformity?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 33 2014-07-01 2014-07-01 false What emission testing must I perform... emission testing must I perform for my application for a certificate of conformity? This section describes the emission testing you must perform to show compliance with the emission standards in subpart B of...

  12. 40 CFR 1060.235 - What emission testing must I perform for my application for a certificate of conformity?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 32 2010-07-01 2010-07-01 false What emission testing must I perform... emission testing must I perform for my application for a certificate of conformity? This section describes the emission testing you must perform to show compliance with the emission standards in subpart B of...

  13. 40 CFR 1060.235 - What emission testing must I perform for my application for a certificate of conformity?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 34 2012-07-01 2012-07-01 false What emission testing must I perform... emission testing must I perform for my application for a certificate of conformity? This section describes the emission testing you must perform to show compliance with the emission standards in subpart B of...

  14. 40 CFR 1060.235 - What emission testing must I perform for my application for a certificate of conformity?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 33 2011-07-01 2011-07-01 false What emission testing must I perform... emission testing must I perform for my application for a certificate of conformity? This section describes the emission testing you must perform to show compliance with the emission standards in subpart B of...

  15. A model for routine hospital-wide HIV screening: lessons learned and public health implications.

    PubMed

    Maxwell, Celia J; Sitapati, Amy M; Abdus-Salaam, Sayyida S; Scott, Victor; Martin, Marsha; Holt-Brockenbrough, Maya E; Retland, Nicole L

    2010-12-01

    Approximately 232700 (21%) of Americans are unaware of their HIV-seropositive status; this represents a potential for virus transmission. Revised recommendations from the Centers for Disease Control for HIV screening promote routine screening in the health care setting. We describe the implementation of a hospital-wide routine HIV screening program in the District of Columbia. Rapid HIV testing was conducted at Howard University Hospital on consenting patients at least 18 years of age using the OraSure OraQuick Advance Rapid HIV-1/2 Antibody Test. The study population includes Howard University Hospital patients who were offered HIV screening over a 12-month period at no cost. Screened patients received immediate test results and, for those patients found to be preliminarily reactive, confirmatory testing and linkage to care were offered. Of the 12836 patients who were offered testing, 7528 (58.6%) consented. Preliminary reactive test results were identified in 176 patients (2.3%). Overall, 45.5% were confirmed, of which 82.5% were confirmed positive. Screening protocol changes have led to 100% confirmation since implementation. Hospital-wide routine HIV screening is feasible and can be implemented effectively and efficiently. The HIV screening campaign instituted at Howard University Hospital identified a substantial number of HIV-positive individuals and provided critical connection to follow-up testing, counseling, and disease management services.

  16. Impact of screening colonoscopy on outcomes in colorectal cancer.

    PubMed

    Matsuda, Takahisa; Ono, Akiko; Kakugawa, Yasuo; Matsumoto, Minori; Saito, Yutaka

    2015-10-01

    Colorectal cancer is one of the most common cancers in both men and women worldwide and a good candidate for screening programs. There are two modalities of colorectal cancer screening: (i) population-based screening and (ii) opportunistic screening. The first one is based on organized, well-coordinated, monitored and established programs with a systematic invitation covering the entire target population. In contrast, opportunistic screening tests are offered to people who are being examined for other reasons. Recently, a variety of colorectal cancer screening tests have become available; each country should make a choice, based on national demographics and resources, on the screening method to be used. Fecal occult blood test, especially the fecal immunochemical test, would be the best modality for decreasing colorectal cancer mortality through population-based screening. In contrast, if the aim includes the early detection of colorectal cancer and adenomas, endoscopic methods are more appropriate. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  17. A questionnaire study of cervical cancer screening beliefs and practices of Chinese and Caucasian mother-daughter pairs living in Canada.

    PubMed

    Chang, Sabrina C H; Woo, Jane S T; Gorzalka, Boris B; Brotto, Lori A

    2010-03-01

    Papanicolaou (Pap) testing rates among Chinese women remain low compared with their Caucasian counterparts despite extensive efforts to raise awareness of the importance of regular screening. We examined three potential predictors of Pap testing behaviour in Chinese women: acculturation, cervical cancer screening belief accuracy, and intergenerational transmission. Caucasian (n = 78) and Chinese (n = 93) female university students and their mothers completed questionnaires concerning acculturation, Pap testing beliefs, and behaviours. Ethnic group comparisons revealed that Chinese daughters and mothers had lower Pap testing rates and less accurate beliefs regarding cervical cancer screening. Among women who had had at least one Pap test, there was no ethnic difference in the proportion of women who adhered to the recommended screening frequency. Among the Chinese women, lower heritage acculturation was correlated with higher cancer screening belief accuracy in both the daughters and their mothers. Maternal Pap testing behaviour was predicted by level of cancer screening belief accuracy, whereas daughters' Pap testing behaviour was predicted by previous experience of sexual intercourse and heritage acculturation. No intergenerational transmission of Pap testing beliefs or behaviours was found. The accuracy of cancer screening beliefs, level of acculturation and experience of sexual intercourse may be predictors of Pap testing behaviour in Chinese women. Contrary to our prediction, we found no support for intergenerational transmission, suggesting that Pap testing beliefs and behaviours of Chinese women are independent of the beliefs and behaviours of their mothers.

  18. Early Pregnancy Diabetes Screening and Diagnosis: Prevalence, Rates of Abnormal Test Results, and Associated Factors.

    PubMed

    Mission, John F; Catov, Janet; Deihl, Tiffany E; Feghali, Maisa; Scifres, Christina

    2017-11-01

    To evaluate the prevalence of early diabetes screening in pregnancy, rates of abnormal diabetes test results before 24 weeks of gestation, and factors associated with early diabetes screening. This was a retrospective cohort study of all singleton deliveries from 2012 to 2014 among diverse clinical practices at a large academic medical center. We assessed rates of early (less than 24 weeks of gestation) and routine (at or beyond 24 weeks of gestation) diabetes screening, with abnormal test results defined using the Carpenter-Coustan criteria, a 50-g glucose challenge test result greater than 200 mg/dL, or a hemoglobin A1C level greater than 6.5%. Univariate and multivariate analyses were used to evaluate clinical and demographic determinants of screening and diagnosis. Overall, 1,420 of 11,331 (12.5%) women underwent early screening. Increasing body mass index (BMI) category, race, public insurance, history of gestational diabetes mellitus, a family history of diabetes, and chronic hypertension were associated with early screening. Early screening rates rose with increasing BMI category, but only 268 of 551 (48.6%) of women with class III obesity underwent early screening. Among those screened early, 2.0% of normal-weight women, 4.0% of overweight women, 4.2% of class I obese women, 3.8% of class II obese women, and 9.0% of class III obese women had abnormal early test results (P<.001). Early diabetes screening is used inconsistently, and many women with risk factors do not undergo early screening. A significant proportion of women with class III obesity will test positive for gestational diabetes mellitus before 24 weeks of gestation, and studies are urgently needed to assess the effect of early diabetes screening and diagnosis on perinatal outcomes in high-risk women.

  19. [Comparison of screening performance between primary high-risk HPV screening and high-risk HPV screening plus liquid-based cytology cotesting in diagnosis of cervical precancerous or cancerous lesions].

    PubMed

    Zhao, X L; Remila, Rezhake; Hu, S Y; Zhang, L; Xu, X Q; Chen, F; Pan, Q J; Zhang, X; Zhao, F H

    2018-05-06

    Objective: To evaluate and compare the screening performance of primary high-risk HPV(HR-HPV) screening and HR-HPV screening plus liquid-based cytology (LBC) cotesting in diagnosis of cervical cancer and precancerous lesions (CIN2+). Methods: We pooled 17 population-based cross-sectional studies which were conducted across China from 1999 to 2008. After obtaining informed consent, all women received liquid-based cytology(LBC)testing, HR-HPV DNA testing. Totally 28 777 women with complete LBC, HPV and biopsy results were included in the final analysis. Screening performance of primary HR-HPV DNA screening and HPV screening plus LBC co-testing in diagnosis of CIN2+ were calculated and compared among different age groups. Results: Among the whole population, the detection rates of primary HR-HPV screening and HR-HPV screening plus LBC co-testing are 3.05% (879 CIN2+) and 3.13%(900 CIN2+), respectively. The sensitivity were 96.4% and 98.7% (χ(2)=19.00, P< 0.001), and the specificity were 86.2% and 78.8% (χ(2)=2 067.00, P< 0.001), respectively. Areas under the receiver operating characteristic (ROC) curve (AUC) showed that the primary HR-HPV screening performed better than co-testing (AUC were 0.913 and 0.888; Z= 6.16, P< 0.001). Compared with primary HR-HPV screening, co-testing showed significantly higher colposcopy referral rates (16.5% and 23.6%, respectively, χ(2)=132.00, P< 0.001) and the number of colposcopy examination for detecting per CIN2+ (5.4 and 7.6, respectively).In the group aged 25-29, the colposcopy referral rates was 8.7 (10.9%(199 cases) vs 1.3%(23 cases)) times as much as the detection rate of primary HR-HPV screening in diagnosis of CIN2+, and was 12.5 (15.7%(288 cases) vs 1.3%(23 cases)) times as much as the detection rate of HR-HPV screening plus cytology contesting. Conclusion: Compared with primary HR-HPV screening, HR-HPV screening plus cytology co-testing does not show better results in the screening performance for CIN2+ detection, and the cost-effectiveness is not good enough, especially in younger age group.

  20. Multimodal lung cancer screening using the ITALUNG biomarker panel and low dose computed tomography. Results of the ITALUNG biomarker study.

    PubMed

    Carozzi, Francesca Maria; Bisanzi, Simonetta; Carrozzi, Laura; Falaschi, Fabio; Lopes Pegna, Andrea; Mascalchi, Mario; Picozzi, Giulia; Peluso, Marco; Sani, Cristina; Greco, Luana; Ocello, Cristina; Paci, Eugenio

    2017-07-01

    Asymptomatic high-risk subjects, randomized in the intervention arm of the ITALUNG trial (1,406 screened for lung cancer), were enrolled for the ITALUNG biomarker study (n = 1,356), in which samples of blood and sputum were analyzed for plasma DNA quantification (cut off 5 ng/ml), loss of heterozygosity and microsatellite instability. The ITALUNG biomarker panel (IBP) was considered positive if at least one of the two biomarkers included in the panel was positive. Subjects with and without lung cancer diagnosis at the end of the screening cycle with LDCT (n = 517) were evaluated. Out of 18 baseline screen detected lung cancer cases, 17 were IBP positive (94%). Repeat screen-detected lung cancer cases were 18 and 12 of them positive at baseline IBP test (66%). Interval cancer cases (2-years) and biomarker tests after a suspect Non Calcific Nodule follow-up were investigated. The single test versus multimodal screening measures of accuracy were compared in a simulation within the screened ITALUNG intervention arm, considering screen-detected and interval cancer cases. Sensitivity was 90% at baseline screening. Specificity was 71 and 61% for LDCT and IBP as baseline single test, and improved at 89% with multimodal, combined screening. The positive predictive value was 4.3% for LDCT at baseline and 10.6% for multimodal screening. Multimodal screening could improve the screening efficiency at baseline and strategies for future implementation are discussed. If IBP was used as primary screening test, the LDCT burden might decrease of about 60%. © 2017 UICC.

  1. Detection and identification of occult HBV in blood donors in Taiwan using a commercial, multiplex, multi-dye nucleic acid amplification technology screening test.

    PubMed

    Lin, K T; Chang, C L; Tsai, M H; Lin, K S; Saldanha, J; Hung, C M

    2014-02-01

    The ability of a new generation commercial, multiplex, multi-dye test from Roche, the cobas TaqScreen MPX test, version 2.0, to detect and identify occult HBV infections was evaluated using routine donor samples from Kaohsiung Blood Bank, Taiwan. A total of 5973 samples were tested by nucleic acid amplification technology (NAT); 5898 in pools of six, 66 in pools of less than six and nine samples individually. NAT-reactive samples were retested with alternative NAT tests, and follow-up samples from the donors were tested individually by NAT and for all the HBV serological markers. Eight NAT-only-reactive donors were identified, and follow-up samples were obtained from six of the donors. The results indicated that all eight donors had an occult HBV infection with viral loads <12 IU/ml. The cobas(®) TaqScreen MPX test, version 2.0, has an advantage over the current Roche blood screening test, the cobas TaqScreen MPX test, for screening donations in countries with a high prevalence of occult HBV infections since the uncertainty associated with identifying samples with very low viremia is removed by the ability of the test to identify the viral target in samples that are reactive with the cobas TaqScreen MPX test, version 2.0. © 2013 International Society of Blood Transfusion.

  2. 40 CFR 1042.240 - Demonstrating compliance with exhaust emission standards.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... emissions at the low-hour test point. For example, if you use aftertreatment technology that controls... have test results showing official emission results and deteriorated emission levels at or below these standards. This also applies for all test points for emission-data engines within the family used to...

  3. 40 CFR 1042.240 - Demonstrating compliance with exhaust emission standards.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... emissions at the low-hour test point. For example, if you use aftertreatment technology that controls... have test results showing official emission results and deteriorated emission levels at or below these standards. This also applies for all test points for emission-data engines within the family used to...

  4. 40 CFR 1042.240 - Demonstrating compliance with exhaust emission standards.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... emissions at the low-hour test point. For example, if you use aftertreatment technology that controls... have test results showing official emission results and deteriorated emission levels at or below these standards. This also applies for all test points for emission-data engines within the family used to...

  5. 40 CFR 1042.240 - Demonstrating compliance with exhaust emission standards.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... emissions at the low-hour test point. For example, if you use aftertreatment technology that controls... have test results showing official emission results and deteriorated emission levels at or below these standards. This also applies for all test points for emission-data engines within the family used to...

  6. 40 CFR 1042.240 - Demonstrating compliance with exhaust emission standards.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... emissions at the low-hour test point. For example, if you use aftertreatment technology that controls... have test results showing official emission results and deteriorated emission levels at or below these standards. This also applies for all test points for emission-data engines within the family used to...

  7. 40 CFR 86.1824-08 - Durability demonstration procedures for evaporative emissions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... for evaporative emissions. Eligible small-volume manufacturers or small-volume test groups may...-based measurements except the bleed emission test. The standard for bleed emissions applies for the full... manufacturer must conduct at least one evaporative emission test at each of the five different mileage points...

  8. Physiologic Screening Test for Eating Disorders/Disordered Eating Among Female Collegiate Athletes.

    PubMed

    Black, David R.; Larkin, Laurie J.S.; Coster, Daniel C.; Leverenz, Larry J.; Abood, Doris A.

    2003-12-01

    OBJECTIVE: To develop and evaluate a physiologic screening test specifically designed for collegiate female athletes engaged in athletic competition or highly athletic performances in order to detect eating disorders/disordered eating. No such physiologically based test currently exists. METHODS: Subjects included 148 (84.5%) of 175 volunteer, National Collegiate Athletic Association Division I (n = 92), club (n = 15), and dance team (n = 41) athletes 18 to 25 years old who attended a large, Midwestern university. Participants completed 4 tests: 2 normed for the general population (Eating Disorders Inventory-2 and Bulimia Test-Revised); a new physiologic test, developed and pilot tested by the investigators, called the Physiologic Screening Test; and the Eating Disorder Exam 12.0D, a structured, validated, diagnostic interview used for criterion validity. RESULTS: The 18-item Physiologic Screening Test produced the highest sensitivity (87%) and specificity (78%) and was superior to the Eating Disorders Inventory-2 (sensitivity = 62%, specificity = 74%) and Bulimia Test-Revised (sensitivity = 27%, specificity = 99%). A substantial number (n = 51, 35%) of athletes were classified as eating disordered/disordered eating. CONCLUSIONS: The Physiologic Screening Test should be considered for screening athletes for eating disorders/disordered eating. The Physiologic Screening Test seems to be a viable alternative to existing tests because it is specifically designed for female athletes, it is brief (4 measurements and 14 items), and validity is enhanced and response bias is lessened because the purpose is less obvious, especially when included as part of a mandatory preparticipation examination.

  9. Providing detailed information about latent tuberculosis and compliance with the PPD test among healthcare workers in Israel: a randomized controlled study.

    PubMed

    Taubman, Danielle; Titler, Nava; Edelstein, Hana; Elias, Mazen; Saliba, Walid

    2013-12-01

    The compliance of screening for latent tuberculosis (TB) with the tuberculin purified protein derivative (PPD) test is very low among healthcare workers (HCWs) in Israel. This randomized controlled study uses the Health Belief Model (HBM) as a conceptual framework to examine whether providing more information about latent TB and the PPD test increases the response rate for PPD screening among HCWs. All candidate HCWs for latent TB screening were randomly allocated to one of the following two invitations to perform the PPD test: regular letter (control group, n=97), and a letter with information about latent TB and the PPD test (intervention group, n=196). 293 HCWs were included (185 nurses, and 108 physicians). Overall, 36 (12.3%) HCWs were compliant with the PPD test screening. Compliance with PPD testing in the intervention group was not statistically different from the control group, RR 0.87 (95% CI, 0.46-1.65). Compliance for latent TB screening is low among HCWs in northeastern Israel. Providing detailed information about latent TB was not associated with increased test compliance. Understanding existing disparities in screening rates and potential barriers to latent TB screening among HCWs is important in order to move forward and successfully increase screening rates. Copyright © 2013 Ministry of Health, Saudi Arabia. Published by Elsevier Ltd. All rights reserved.

  10. 40 CFR Appendix A to Subpart D of... - Tables

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... fitted for the test kW PB Total barometric pressure (average of the pre-test and post-test values) kPa...) CONTROL OF EMISSIONS FROM MARINE SPARK-IGNITION ENGINES Emission Test Equipment Provisions Pt. 91, Subpt... Term Unit AYM Final weighted emission test results g/kW-hr C3 H8 Propane CB Concentration of emission...

  11. 40 CFR Appendix A to Subpart D of... - Tables

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... fitted for the test kW PB Total barometric pressure (average of the pre-test and post-test values) kPa...) CONTROL OF EMISSIONS FROM MARINE SPARK-IGNITION ENGINES Emission Test Equipment Provisions Pt. 91, Subpt... Term Unit AYM Final weighted emission test results g/kW-hr C3 H8 Propane CB Concentration of emission...

  12. 40 CFR Appendix A to Subpart D of... - Tables

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... fitted for the test kW PB Total barometric pressure (average of the pre-test and post-test values) kPa...) CONTROL OF EMISSIONS FROM MARINE SPARK-IGNITION ENGINES Emission Test Equipment Provisions Pt. 91, Subpt... Term Unit AYM Final weighted emission test results g/kW-hr C3 H8 Propane CB Concentration of emission...

  13. 40 CFR Appendix A to Subpart D of... - Tables

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... fitted for the test kW PB Total barometric pressure (average of the pre-test and post-test values) kPa...) CONTROL OF EMISSIONS FROM MARINE SPARK-IGNITION ENGINES Emission Test Equipment Provisions Pt. 91, Subpt... Term Unit AYM Final weighted emission test results g/kW-hr C3 H8 Propane CB Concentration of emission...

  14. 40 CFR Appendix A to Subpart D of... - Tables

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... fitted for the test kW PB Total barometric pressure (average of the pre-test and post-test values) kPa...) CONTROL OF EMISSIONS FROM MARINE SPARK-IGNITION ENGINES Emission Test Equipment Provisions Pt. 91, Subpt... Term Unit AYM Final weighted emission test results g/kW-hr C3 H8 Propane CB Concentration of emission...

  15. Rapid mix concepts for low emission combustors in gas turbine engines

    NASA Technical Reports Server (NTRS)

    Talpallikar, Milind V.; Smith, Clifford E.; Lai, Ming-Chia

    1990-01-01

    NASA LeRC has identified the Rich burn/Quick mix/Lean burn (RQL) combustor as a potential gas turbine combustor concept to reduce NOx emissions in High Speed Civil Transport (HSCT) aircraft. To demonstrate reduced NOx levels, NASA LeRC soon will test a flametube version of an RQL combustor. The critical technology needed for the RQL combustor is a method of quickly mixing combustion air with rich burn gases. Two concepts were proposed to enhance jet mixing in a circular cross-section: the Asymmetric Jet Penetration (AJP) concept; and the Lobed Mixer (LM) concept. In Phase 1, two preliminary configurations of the AJP concept were compared with a conventional 12-jet radial-inflow slot design. The configurations were screened using an advanced 3-D Computational Fluid Dynamics (CFD) code named REFLEQS. Both non-reacting and reacting analyses were performed. For an objective comparison, the conventional design was optimized by parametric variation of the jet-to-mainstream momentum flux (J) ratio. The optimum J was then employed in the AJP simulations. Results showed that the three-jet AJP configuration was superior in overall mixedness compared to the conventional design. However, in regards to NOx emissions, the AJP configuration was inferior. The higher emission level for AJP was caused by a single hot spot located in the wake of the central jet as it entered the combustor. Ways of maintaining good mixedness while eliminating the hot spot were identified for Phase 2 study. Overall, Phase 1 showed the viability of using CFD analyses to evaluate quick-mix concepts. A high probability exists that advancing mixing concepts will reduce NOx emissions in RQL combustors, and should be explored in Phase 2, by parallel numerical and experimental work.

  16. Case-control studies of the efficacy of cancer screening: overcoming bias from nonrandom patterns of screening.

    PubMed

    Weiss, Noel S; Dhillon, Preet K; Etzioni, Ruth

    2004-07-01

    A case-control study of the efficacy of cancer screening, like any other case-control study, must deal with potential confounding. There are 2 categories of confounding variables that pose special problems for studies of screening: (1) age and calendar time resulting from different temporal distributions of screening between cases and controls irrespective of whether the screening test leads to a reduction in mortality; and (2) the administration of other screening tests for the cancer in question when it is not clear whether the result of the other test had a bearing on the decision to order the test under study. We describe circumstances in which confounding from these sources can be dealt with satisfactorily by means of restriction or adjustment, and other circumstances in which it cannot. Copyright 2004 Lippincott Williams and Wilkins

  17. Esophageal Cancer Screening (PDQ®)—Patient Version

    Cancer.gov

    Esophageal cancer screening is not currently considered to be a routine part of cancer screening. Not all screening tests are helpful, and many have risks. Learn more about esophageal cancer risk factors and tests to detect it in this expert-reviewed summary.

  18. Colorectal Cancer Screening (PDQ®)—Health Professional Version

    Cancer.gov

    Colorectal cancer (CRC) screening reduces CRC mortality; some screening modalities also reduce CRC incidence. Get detailed information about CRC screening tests (e.g., fecal occult blood test, sigmoidoscopy, colonoscopy, stool DNA) including potential benefits and harms in this clinician summary.

  19. Oral Cancer Screening

    MedlinePlus

    ... decrease the risk of dying from cancer. Scientists study screening tests to find those with the fewest risks and ... website . There is no standard or routine screening test for oral cavity, pharyngeal, and laryngeal cancer. No studies have shown that screening for oral cavity , pharyngeal , ...

  20. Controversies in colorectal cancer screening.

    PubMed

    Pox, Christian P

    2014-01-01

    Colorectal cancer (CRC) is one of the most common cancers worldwide and a good candidate for screening programmes. However, there is controversy concerning which of the available screening tests should be used. There is general agreement that screening for CRC in the asymptomatic population should begin at the age of 50. Several different screening methods are available which can be separated into those that mainly detect cancers: faecal occult blood tests [guaiac (FOBT) and immunochemical (FIT)], genetic stool tests, blood tests and the M2-pyruvate kinase (M2-PK) test. Methods that detect cancers and polyps are colonoscopy, sigmoidoscopy, CT-colonography (CT-C) and colon capsule endoscopy. The only tests for which a reduction in CRC mortality compared to no screening have been proven in randomized trials are FOBT and sigmoidoscopy. Several trials suggest that FIT are superior to FOBT in terms of detection rates of cancers and advanced adenomas and possibly compliance. There is indirect evidence suggesting efficacy of colonoscopy as a screening test. The role of CT-C is controversial. There is data suggesting a good sensitivity for neoplasia >9 mm with a lower sensitivity for smaller neoplasia. However, radiation exposure is considered a major limitation in some countries. Unresolved questions include the lesion cut-off for referral to colonoscopy and work-up of extracolonic findings. For other methods, like genetic stool testing using newer markers, blood tests, capsule endoscopy and M2-PK, there is currently insufficient data on screening of the asymptomatic population. Key Messages: Colorectal screening is recommended and should be performed in the form of an organized programme. If detection of early-stage cancers is the aim of a screening programme, FIT seem to be superior to FOBT. If detection and removal of adenomas is the aim of a screening programme, endoscopic methods seem to be good alternatives. Sigmoidoscopy is easier to perform but will likely only have an effect on distal cancers. Colonoscopy is more invasive but enables inspection of the whole colon. The role of CT-C, capsule endoscopy, genetic stool tests, blood tests and M2-PK is currently unknown. © 2014 S. Karger AG, Basel.

  1. [New guidelines in regard to cervical cancer screening].

    PubMed

    Vargas-Hernández, Víctor Manuel; Acosta-Altamirano, Gustavo; Moreno-Eutimio, Mario Adán; Vargas-Aguilar, Víctor Manuel

    2014-01-01

    Cancer screening programs have been successful in reducing the incidence and mortality due to cervical cancer. For more than a decade, the human papillomavirus test has been recommended as part of these programs, however, Pap tests is not currently recommended for women 65 years of age who participated adequately in screening programs, continuing with these screening programs is not needed. Screening programs will be different in special populations at greatest risk where tests are frequently needed or use of alternative methods.

  2. Use of screening tests to assess cancer risk and to estimate the risk of adult T-cell leukemia/lymphoma.

    PubMed Central

    Yanagawa, T; Tokudome, S

    1990-01-01

    We developed methods to assess the cancer risks by screening tests. These methods estimate the size of the high risk group adjusted for the characteristics of screening tests and estimate the incidence rates of cancer among the high risk group adjusted for the characteristics of the tests. A method was also developed for selecting the cut-off point of a screening test. Finally, the methods were applied to estimate the risk of the adult T-cell leukemia/lymphoma. PMID:2269244

  3. Screening for gonorrhoea using samples collected through the English National Chlamydia Screening Programme and risk of false positives: a national survey of Local Authorities

    PubMed Central

    Field, Nigel; Kennedy, Iain; Folkard, Kate; Duffell, Stephen; Town, Katy; Ison, Catherine A; Hughes, Gwenda

    2014-01-01

    Objectives To investigate use of dual tests for Chlamydia trachomatis and Neisseria gonorrhoeae on samples collected through the National Chlamydia Screening Programme (NCSP) in England. Design and setting During May–July 2013, we delivered an online survey to commissioners of sexual health services in the 152 upper-tier English Local Authorities (LAs) who were responsible for commissioning chlamydia screening in people aged 15–24 years. Main outcome measures (1) The proportion of English LAs using dual tests on samples collected by the NCSP; (2) The estimated number of gonorrhoea tests and false positives from samples collected by the NCSP, calculated using national surveillance data on the number of chlamydia tests performed, assuming the gonorrhoea prevalence to range between 0.1% and 1%, and test sensitivity and specificity of 99.5%. Results 64% (98/152) of LAs responded to this national survey; over half (53% (52/98)) reported currently using dual tests in community settings. There was no significant difference between LAs using and not using dual tests by chlamydia positivity, chlamydia diagnosis rate or population screening coverage. Although positive gonorrhoea results were confirmed with supplementary tests in 93% (38/41) of LAs, this occurred after patients were notified about the initial positive result in 63% (26/41). Approximately 450–4500 confirmed gonorrhoea diagnoses and 2300 false-positive screens might occur through use of dual tests on NCSP samples each year. Under reasonable assumptions, the positive predictive value of the screening test is 17–67%. Conclusions Over half of English LAs already commission dual tests for samples collected by the NCSP. Gonorrhoea screening has been introduced alongside chlamydia screening in many low prevalence settings without a national evidence review or change of policy. We question the public health benefit here, and suggest that robust testing algorithms and clinical management pathways, together with rigorous evaluation, be implemented wherever dual tests are deployed. PMID:25324326

  4. Factors Accounting for a Missed Diagnosis of Cystic Fibrosis After Newborn Screening

    PubMed Central

    Rock, Michael J.; Levy, Hara; Zaleski, Christina; Farrell, Philip M.

    2015-01-01

    Summary Newborn screening is a public health policy program involving the centralized testing laboratory, infant and their family, primary care provider, and subspecialist for confirmatory testing and follow-up of abnormal results. Cystic fibrosis (CF) newborn screening has now been enacted in all 50 states and the District of Columbia and throughout many countries in the world. Although CF neonatal screening will identify the vast majority of infants with CF, there are many factors in the newborn screening system that can lead to a missed diagnosis of CF. To inform clinicians, this article summarizes the CF newborn screening system and highlights 14 factors that can account for a missed diagnosis of CF. Care providers should maintain a high suspicion for CF if there are compatible symptoms, regardless of the results of the newborn screening test. These factors in newborn screening programs leading to a missed diagnosis of CF present opportunities for quality improvement in specimen collection, laboratory analysis of immunoreactive tryspinogen (IRT) and CF mutation testing, communication, and sweat testing. PMID:22081556

  5. Valuing experience factors in the provision of Chlamydia screening: an application to women attending the family planning clinic.

    PubMed

    Watson, Verity; Ryan, Mandy; Watson, Emma

    2009-06-01

    To examine women's preferences for characteristics of chlamydia screening. Chlamydia trachomatis is the most common curable sexually transmitted disease. To design effective screening programs, it is important to fully capture the benefits of screening to patients. Thus, the value of experience factors must be considered alongside health outcomes. A self-complete discrete choice experiment questionnaire was administered to women attending a family planning clinic. Chlamydia screening was described by five characteristics: location of screening; type of screening test; cost of screening test; risk of developing pelvic inflammatory disease if chlamydia is untreated; and support provided when receiving results. One hundred twenty-six women completed the questionnaire. Respondents valued characteristics of the care experience. Screening was valued at 15 pound; less invasive screening tests increase willingness to pay by 7 pound, and more invasive tests reduce willingness to pay by 3.50 pound. The most preferred screening location was the family planning clinic, valued at 5 pound. The support of a trained health-care professional when receiving results was valued at 4 pound. Respondents under 25 years and those in a casual relationship were less likely to be screened. Women valued experience factors in the provision of chlamydia screening. To correctly value these screening programs and to predict uptake, cost-effectiveness studies should take such values into account. Failure to do this may result in incorrect policy recommendations.

  6. Screening health care workers with interferon-γ release assay versus tuberculin skin test: impact on costs and adherence to testing (the SWITCH study).

    PubMed

    Wrighton-Smith, Peter; Sneed, Laurie; Humphrey, Frances; Tao, Xuguang; Bernacki, Edward

    2012-07-01

    To determine the price point at which an interferon-γ release assay (IGRA) is less costly than a tuberculin skin test (TST) for health care employee tuberculosis screening. A multidecision tree-based cost model incorporating inputs gathered from time-motion studies and parallel testing by IGRA and TST was conducted in a subset of our employees. Administering a TST testing program costs $73.20 per person screened, $90.80 per new hire, and $63.42 per annual screen. Use of an IGRA for employee health testing is cost saving at an IGRA test cost of $54.83 or less per test and resulted in higher completion rates because of the elimination of the need for a second visit to interpret the TST. Using an IGRA for employee health screening can be an institutional cost saving and results in higher compliance rates.

  7. Screening photoswitching properties of synthesized BODIPY-based fluorophores for multispectral superresolution microscopy (MSSRM) (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Bittel, Amy M.; Saldivar, Isaac S.; Nan, Xiaolin; Gibbs, Summer L.

    2016-02-01

    Single-molecule localization microscopy (SMLM) utilizes photoswitchable fluorophores to detect biological entities with 10-20 nm resolution. Multispectral superresolution microscopy (MSSRM) extends SMLM functionality by improving its spectral resolution up to 5 fold facilitating imaging of multicomponent cellular structures or signaling pathways. Current commercial fluorophores are not ideal for MSSRM as they are not designed to photoswitch and do not adequately cover the visible and far-red spectral regions required for MSSRM imaging. To obtain optimal MSSRM spatial and spectral resolution, fluorophores with narrow emission spectra and controllable photoswitching properties are necessary. Herein, a library of BODIPY-based fluorophores was synthesized and characterized to create optimal photoswitchable fluorophores for MSSRM. BODIPY was chosen as the core structure as it is photostable, has high quantum yield, and controllable photoswitching. The BODIPY core was modified through the addition of various aromatic moieties, resulting in a spectrally diverse library. Photoswitching properties were characterized using a novel polyvinyl alcohol (PVA) based film methodology to isolate single molecules. The PVA film methodology enabled photoswitching assessment without the need for protein conjugation, greatly improving screening efficiency of the BODIPY library. Additionally, image buffer conditions were optimized for the BODIPY-based fluorophores through systematic testing of oxygen scavenger systems, redox components, and additives. Through screening the photoswitching properties of BODIPY-based compounds in PVA films with optimized imaging buffer we identified novel fluorophores well suited for SMLM and MSSRM.

  8. Does Assessing Eye Alignment along with Refractive Error or Visual Acuity Increase Sensitivity for Detection of Strabismus in Preschool Vision Screening?

    PubMed Central

    2007-01-01

    Purpose Preschool vision screenings often include refractive error or visual acuity (VA) testing to detect amblyopia, as well as alignment testing to detect strabismus. The purpose of this study was to determine the effect of combining screening for eye alignment with screening for refractive error or reduced VA on sensitivity for detection of strabismus, with specificity set at 90% and 94%. Methods Over 3 years, 4040 preschool children were screened in the Vision in Preschoolers (VIP) Study, with different screening tests administered each year. Examinations were performed to identify children with strabismus. The best screening tests for detecting children with any targeted condition were noncycloplegic retinoscopy (NCR), Retinomax autorefractor (Right Manufacturing, Virginia Beach, VA), SureSight Vision Screener (Welch-Allyn, Inc., Skaneateles, NY), and Lea Symbols (Precision Vision, LaSalle, IL and Good-Lite Co., Elgin, IL) and HOTV optotypes VA tests. Analyses were conducted with these tests of refractive error or VA paired with the best tests for detecting strabismus (unilateral cover testing, Random Dot “E” [RDE] and Stereo Smile Test II [Stereo Optical, Inc., Chicago, IL]; and MTI PhotoScreener [PhotoScreener, Inc., Palm Beach, FL]). The change in sensitivity that resulted from combining a test of eye alignment with a test of refractive error or VA was determined with specificity set at 90% and 94%. Results Among the 4040 children, 157 were identified as having strabismus. For screening tests conducted by eye care professionals, the addition of a unilateral cover test to a test of refraction generally resulted in a statistically significant increase (range, 15%–25%) in detection of strabismus. For screening tests administered by trained lay screeners, the addition of Stereo Smile II to SureSight resulted in a statistically significant increase (21%) in sensitivity for detection of strabismus. Conclusions The most efficient and low-cost ways to achieve a statistically significant increase in sensitivity for detection of strabismus were by combining the unilateral cover test with the autorefractor (Retinomax) administered by eye care professionals and by combining Stereo Smile II with SureSight administered by trained lay screeners. The decision of whether to include a test of alignment should be based on the screening program’s goals (e.g., targeted visual conditions) and resources. PMID:17591881

  9. Electron emission from chemical vapor deposited diamond and amorphous carbon films observed with a simple field emission device

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Feng, Z.; Brown, I.G.; Ager, J.W. III

    Electron emission from chemical vapor deposited (CVD) diamond and amorphous carbon (a-C) films was observed with a simple field emission device (FED). Both diamond and a-C films were prepared with microwave plasma-enhanced CVD techniques. Electron emission in the field strength range +10 to {minus}10 MVm{sup {minus}1} was studied, and the field emission source was confirmed by a diode characteristic of the {ital I}-{ital V} curve, a straight line in the Fowler--Nordheim (F-N) plot, and direct observation of light emission from a fluorescent screen. The turn-on field strength was {similar_to}5 MVm{sup {minus}1}, which was similar for both kinds of carbon films.more » The highest current density for diamond films, observed at a field strength of 10 MVm{sup {minus}1}, was {similar_to}15 {mu}A cm{sup {minus}2}. Diamond films yielded a higher emission current than a-C films. The reasons for the observed field emission are discussed.« less

  10. Colorectal cancer screening: An updated review of the available options.

    PubMed

    Issa, Iyad A; Noureddine, Malak

    2017-07-28

    Colorectal cancer (CRC) is a significant cause of morbidity and mortality worldwide. However, colon cancer incidence and mortality is declining over the past decade owing to adoption of effective screening programs. Nevertheless, in some parts of the world, CRC incidence and mortality remain on the rise, likely due to factors including "westernized" diet, lifestyle, and lack of health-care infrastructure and resources. Participation and adherence to different national screening programs remain obstacles limiting the achievement of screening goals. Different modalities are available ranging from stool based tests to radiology and endoscopy with varying sensitivity and specificity. However, the availability of these tests is limited to areas with high economic resources. Recently, FDA approved a blood-based test (Epi procolon ® ) for CRC screening. This blood based test may serve to increase the participation and adherence rates. Hence, leading to increase in colon cancer detection and prevention. This article will discuss various CRC screening tests with a particular focus on the data regarding the new approved blood test. Finally, we will propose an algorithm for a simple cost-effective CRC screening program.

  11. Colorectal cancer screening: An updated review of the available options

    PubMed Central

    Issa, Iyad A; Noureddine, Malak

    2017-01-01

    Colorectal cancer (CRC) is a significant cause of morbidity and mortality worldwide. However, colon cancer incidence and mortality is declining over the past decade owing to adoption of effective screening programs. Nevertheless, in some parts of the world, CRC incidence and mortality remain on the rise, likely due to factors including “westernized” diet, lifestyle, and lack of health-care infrastructure and resources. Participation and adherence to different national screening programs remain obstacles limiting the achievement of screening goals. Different modalities are available ranging from stool based tests to radiology and endoscopy with varying sensitivity and specificity. However, the availability of these tests is limited to areas with high economic resources. Recently, FDA approved a blood-based test (Epi procolon®) for CRC screening. This blood based test may serve to increase the participation and adherence rates. Hence, leading to increase in colon cancer detection and prevention. This article will discuss various CRC screening tests with a particular focus on the data regarding the new approved blood test. Finally, we will propose an algorithm for a simple cost-effective CRC screening program. PMID:28811705

  12. Screening and Biosensor-Based Approaches for Lung Cancer Detection

    PubMed Central

    Wang, Lulu

    2017-01-01

    Early diagnosis of lung cancer helps to reduce the cancer death rate significantly. Over the years, investigators worldwide have extensively investigated many screening modalities for lung cancer detection, including computerized tomography, chest X-ray, positron emission tomography, sputum cytology, magnetic resonance imaging and biopsy. However, these techniques are not suitable for patients with other pathologies. Developing a rapid and sensitive technique for early diagnosis of lung cancer is urgently needed. Biosensor-based techniques have been recently recommended as a rapid and cost-effective tool for early diagnosis of lung tumor markers. This paper reviews the recent development in screening and biosensor-based techniques for early lung cancer detection. PMID:29065541

  13. Estimating the positive predictive value of opportunistic population testing for gonorrhoea as part of the English Chlamydia Screening Programme.

    PubMed

    Fowler, T; Edeghere, O; Inglis, N; Bradshaw, S

    2013-03-01

    Advances in technology have raised the possibility of including gonorrhoea testing as part of chlamydia screening. In England this is recommended only where the positive predictive value (PPV) of the test is ≥90%. This study assessed the PPV for gonorrhoea testing using routine testing data. Routine data (including gonorrhoea testing) from the Greater Manchester Chlamydia Screening Programme (GMCSP) in 2009/2010, were used to estimate the PPV for gonorrhoea testing. Of those screened, 0.3% (59/18044) of men and 0.4% (174/41873) of women tested positive for gonorrhoea. The PPV was 82.3% in women and 73.6% in men, in those who also tested positive for chlamydia. For women and men testing negative for chlamydia the PPV for a positive gonorrhoea test was incalculable. The low PPV observed in most groups suggests that where population testing for gonorrhoea occurs there is a need for further confirmatory testing of positive results before treatment decisions are made. Clinicians should be aware of screening test result limitations in this context.

  14. The cost-effectiveness of screening for colorectal cancer.

    PubMed

    Telford, Jennifer J; Levy, Adrian R; Sambrook, Jennifer C; Zou, Denise; Enns, Robert A

    2010-09-07

    Published decision analyses show that screening for colorectal cancer is cost-effective. However, because of the number of tests available, the optimal screening strategy in Canada is unknown. We estimated the incremental cost-effectiveness of 10 strategies for colorectal cancer screening, as well as no screening, incorporating quality of life, noncompliance and data on the costs and benefits of chemotherapy. We used a probabilistic Markov model to estimate the costs and quality-adjusted life expectancy of 50-year-old average-risk Canadians without screening and with screening by each test. We populated the model with data from the published literature. We calculated costs from the perspective of a third-party payer, with inflation to 2007 Canadian dollars. Of the 10 strategies considered, we focused on three tests currently being used for population screening in some Canadian provinces: low-sensitivity guaiac fecal occult blood test, performed annually; fecal immunochemical test, performed annually; and colonoscopy, performed every 10 years. These strategies reduced the incidence of colorectal cancer by 44%, 65% and 81%, and mortality by 55%, 74% and 83%, respectively, compared with no screening. These strategies generated incremental cost-effectiveness ratios of $9159, $611 and $6133 per quality-adjusted life year, respectively. The findings were robust to probabilistic sensitivity analysis. Colonoscopy every 10 years yielded the greatest net health benefit. Screening for colorectal cancer is cost-effective over conventional levels of willingness to pay. Annual high-sensitivity fecal occult blood testing, such as a fecal immunochemical test, or colonoscopy every 10 years offer the best value for the money in Canada.

  15. Who attends a UK diabetes screening programme? Findings from the ADDITION-Cambridge study.

    PubMed

    Sargeant, L A; Simmons, R K; Barling, R S; Butler, R; Williams, K M; Prevost, A T; Kinmonth, A L; Wareham, N J; Griffin, S J

    2010-09-01

    One of the factors influencing the cost-effectiveness of population screening for Type 2 diabetes may be uptake. We examined attendance and practice- and individual-level factors influencing uptake at each stage of a diabetes screening programme in general practice. A stepwise screening programme was undertaken among 135, 825 people aged 40-69 years without known diabetes in 49 general practices in East England. The programme included a score based on routinely available data (age, sex, body mass index and prescribed medication) to identify those at high risk, who were offered random capillary blood glucose (RBG) and glycosylated haemoglobin tests. Those screening positive were offered fasting capillary blood glucose (FBG) and confirmatory oral glucose tolerance tests (OGTT). There were 33 539 high-risk individuals invited for a RBG screening test; 24 654 (74%) attended. Ninety-four per cent attended the follow-up FBG test and 82% the diagnostic OGTT. Seventy per cent of individuals completed the screening programme. Practices with higher general practitioner staff complements and those located in more deprived areas had lower uptake for RBG and FBG tests. Male sex and a higher body mass index were associated with lower attendance for RBG testing. Older age, prescription of antihypertensive medication and a higher risk score were associated with higher attendance for FBG and RBG tests. High attendance rates can be achieved by targeted stepwise screening of individuals assessed as high risk by data routinely available in general practice. Different strategies may be required to increase initial attendance, ensure completion of the screening programme, and reduce the risk that screening increases health inequalities.

  16. Screening options for Down syndrome: how women choose in real clinical setting.

    PubMed

    Lo, T K; Lai, F K; Leung, W C; Lau, W L; Ng, L S; Wong, W C; Tam, S S; Yee, Y C; Choi, H; Lam, H S W; Sham, A S Y; Tang, L C H; Chin, R K H

    2009-09-01

    To study pregnant women's preference among various screening options for Down syndrome (DS) in routine clinical setting, and its potential association with women's demographic characteristics. Women aged 35 years and older carrying singleton pregnancy were offered a variety of screening tests for DS before 14 weeks of gestation. Their preference was confirmed by the test they actually underwent. The association between women's choice of test and a number of demographic characteristics was studied using multinomial regression. Among 1967 eligible women, 619 opted for first-trimester screening test (FTS), 924 for partial integrated test (PIT), and 424 for full integrated test (FIT). Nulliparous women and working mothers were more likely to choose FTS and FIT. Women with history of subfertility were more likely to choose FIT. Women with family history of chromosomal abnormalities were more likely to choose FTS. The choice of screening test could be predicted for 49.9% of women using four demographic characteristics. Among older women of predominantly Chinese ethnicity, integrated test is a favorite alternative to FTS. Their choice of DS screening test can be predicted by their obstetric and socioeconomic characteristics. Many women show willingness to pay for a test with a lower false-positive rate.

  17. 10 CFR 26.131 - Cutoff levels for validity screening and initial validity tests.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Cutoff levels for validity screening and initial validity tests. 26.131 Section 26.131 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Licensee Testing Facilities § 26.131 Cutoff levels for validity screening and initial validity tests. (a) Each...

  18. 10 CFR 26.131 - Cutoff levels for validity screening and initial validity tests.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 1 2011-01-01 2011-01-01 false Cutoff levels for validity screening and initial validity tests. 26.131 Section 26.131 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Licensee Testing Facilities § 26.131 Cutoff levels for validity screening and initial validity tests. (a) Each...

  19. Cross-Validation of the Computerized Adaptive Screening Test (CAST).

    ERIC Educational Resources Information Center

    Pliske, Rebecca M.; And Others

    The Computerized Adaptive Screening Test (CAST) was developed to provide an estimate at recruiting stations of prospects' Armed Forces Qualification Test (AFQT) scores. The CAST was designed to replace the paper-and-pencil Enlistment Screening Test (EST). The initial validation study of CAST indicated that CAST predicts AFQT at least as accurately…

  20. Impact of single particle oscillations on screening of a test charge

    NASA Astrophysics Data System (ADS)

    Ramazanov, Tlekkabul S.; Moldabekov, Zhandos A.; Gabdullin, Maratbek T.

    2018-06-01

    Screening of a test charge by electrons oscillating in an external alternating electrical (laser) field is analyzed. It is shown that single particle oscillations lead to the creation of an oscillatory pattern of the test charge's potential at large distances. Analysis has been done by considering and neglecting the contribution of ions on the screening. Impact of the quantum diffraction (non-locality) and of the collisional damping on the test charge's potential is considered. It is shown that electrons are unable to provide screening of the test charge if the frequency of the induced single particle oscillations larger than the electron-plasma frequency. In the opposite case of low frequencies, the potential of the test charge changes its sign if the screening by ions is neglected.

  1. Liver (Hepatocellular) Cancer Screening (PDQ®)—Patient Version

    Cancer.gov

    Liver (hepatocellular) cancer screening is not currently recommended as a routine part of cancer screening. Not all screening tests are helpful, and many have risks. Learn more about liver cancer and the tests used to detect it in this expert-reviewed summary.

  2. Characterizing sampling and quality screening biases in infrared and microwave limb sounding

    NASA Astrophysics Data System (ADS)

    Millán, Luis F.; Livesey, Nathaniel J.; Santee, Michelle L.; von Clarmann, Thomas

    2018-03-01

    This study investigates orbital sampling biases and evaluates the additional impact caused by data quality screening for the Michelson Interferometer for Passive Atmospheric Sounding (MIPAS) and the Aura Microwave Limb Sounder (MLS). MIPAS acts as a proxy for typical infrared limb emission sounders, while MLS acts as a proxy for microwave limb sounders. These biases were calculated for temperature and several trace gases by interpolating model fields to real sampling patterns and, additionally, screening those locations as directed by their corresponding quality criteria. Both instruments have dense uniform sampling patterns typical of limb emission sounders, producing almost identical sampling biases. However, there is a substantial difference between the number of locations discarded. MIPAS, as a mid-infrared instrument, is very sensitive to clouds, and measurements affected by them are thus rejected from the analysis. For example, in the tropics, the MIPAS yield is strongly affected by clouds, while MLS is mostly unaffected. The results show that upper-tropospheric sampling biases in zonally averaged data, for both instruments, can be up to 10 to 30 %, depending on the species, and up to 3 K for temperature. For MIPAS, the sampling reduction due to quality screening worsens the biases, leading to values as large as 30 to 100 % for the trace gases and expanding the 3 K bias region for temperature. This type of sampling bias is largely induced by the geophysical origins of the screening (e.g. clouds). Further, analysis of long-term time series reveals that these additional quality screening biases may affect the ability to accurately detect upper-tropospheric long-term changes using such data. In contrast, MLS data quality screening removes sufficiently few points that no additional bias is introduced, although its penetration is limited to the upper troposphere, while MIPAS may cover well into the mid-troposphere in cloud-free scenarios. We emphasize that the results of this study refer only to the representativeness of the respective data, not to their intrinsic quality.

  3. National Air Toxics Assessment

    EPA Pesticide Factsheets

    NATA is an ongoing comprehensive evaluation of air toxics in the U.S. As a screening tool, it helps air agencies prioritize pollutants, emission sources and locations of interest for further study to gain a better understanding of risks.

  4. Caspase-1 Specific Light-Up Probe with Aggregation-Induced Emission Characteristics for Inhibitor Screening of Coumarin-Originated Natural Products.

    PubMed

    Lin, Hao; Yang, Haitao; Huang, Shuai; Wang, Fujia; Wang, Dong-Mei; Liu, Bin; Tang, Yi-Da; Zhang, Chong-Jing

    2018-04-18

    Caspase-1 is a key player in pyroptosis and inflammation. Caspase-1 inhibition is found to be beneficial to various diseases. Coumarin-originated natural products have an anti-inflammation function, but their direct inhibition effect to caspase-1 remains unexplored. To evaluate their interactions, the widely used commercial coumarin-based probe (Ac-YVAD-AMC) is not suitable, as the background signal from coumarin-originated natural products could interfere with the screening results. Therefore, fluorescent probes using a large Stokes shift could help solve this problem. In this work, we chose the fluorophore of tetraphenylethylene-thiophene (TPETH) with aggregation-induced emission characteristics and a large Stokes shift of about 200 nm to develop a molecular probe. Bioconjugation between TPETH and hydrophilic peptides (DDYVADC) through a thiol-ene reaction generated a light-up probe, C1-P3. The probe has little background signal in aqueous media and exerts a fluorescent turn-on effect in the presence of caspase-1. Moreover, when evaluating the inhibition potency of coumarin-originated natural products, the new probe could generate a true and objective result but not for the commercial probe (Ac-YVAD-AMC), which is evidenced by HPLC analysis. The quick light-up response and accurate screening results make C1-P3 very useful in fundamental study and inhibitior screening toward caspase-1.

  5. Results of a 2000 hour wear test of the NEXIS ion engine

    NASA Technical Reports Server (NTRS)

    Snyder, John Steven; Goebel, Dan M.; Polk, James E.; Schneider, Analyn C; Sengupta, Anita

    2005-01-01

    The Nuclear Electric Xenon Ion System (NEXIS) ion thruster was developed for potential outer planet robotic missions under NASA's Prometheus program. This engine was designed to operate at power levels ranging from 16 to over 20 kWe at specific impulses of 6000 to 7500 s for burn times of up to 10 years, satisfying the requirements of nuclear electric propulsion systems such as that on the proposed Prometheus 1 mission to explore the icy moons of Jupiter. State-of-the-art performance and life assessment tools were used to design the thruster. Following the successful performance validation of a Laboratory Model thruster, Development Model hardware was fabricated and subjected to vibration and wear testing. The results of a 2000-hour wear test are reported herein. Thruster performance achieved the target requirements and was steady for the duration of the test. Ion optics performance was similarly stable. Discharge loss increases of 6 eV/ion were observed in the first 500 hours of the test and were attributed to primary electron energy decreases due to cathode insert conditioning. Relatively high recycle rates were observed and were identified to be high-voltage-to-ground arcs in the back of the thruster caused by wire insulation outgassing and electron penetration through the plasma screen. Field emission of electrons between the accelerator and screen grids was observed and attributed to evolution of field emitter sites at accelerator grid aperture edges caused by ion bombardment. Preliminary modeling and analysis indicates that the NEXIS engine can meet mission performance requirements over the required lifetime. Finally, successful validation of the NEXIS design methodology, design tools, and technologies with the results of the wear test and companion performance and vibration tests presents significant applicability of the NEXIS development effort to missions of near-term as well as long-term interest for NASA.

  6. On-road emissions of light-duty vehicles in europe.

    PubMed

    Weiss, Martin; Bonnel, Pierre; Hummel, Rudolf; Provenza, Alessio; Manfredi, Urbano

    2011-10-01

    For obtaining type approval in the European Union, light-duty vehicles have to comply with emission limits during standardized laboratory emissions testing. Although emission limits have become more stringent in past decades, light-duty vehicles remain an important source of nitrogen oxides and carbon monoxide emissions in Europe. Furthermore, persisting air quality problems in many urban areas suggest that laboratory emissions testing may not accurately capture the on-road emissions of light-duty vehicles. To address this issue, we conduct the first comprehensive on-road emissions test of light-duty vehicles with state-of-the-art Portable Emission Measurement Systems. We find that nitrogen oxides emissions of gasoline vehicles as well as carbon monoxide and total hydrocarbon emissions of both diesel and gasoline vehicles generally remain below the respective emission limits. By contrast, nitrogen oxides emissions of diesel vehicles (0.93 ± 0.39 grams per kilometer [g/km]), including modern Euro 5 diesel vehicles (0.62 ± 0.19 g/km), exceed emission limits by 320 ± 90%. On-road carbon dioxide emissions surpass laboratory emission levels by 21 ± 9%, suggesting that the current laboratory emissions testing fails to accurately capture the on-road emissions of light-duty vehicles. Our findings provide the empirical foundation for the European Commission to establish a complementary emissions test procedure for light-duty vehicles. This procedure could be implemented together with more stringent Euro 6 emission limits in 2014. The envisaged measures should improve urban air quality and provide incentive for innovation in the automotive industry.

  7. An experience of qualified preventive screening: shiraz smart screening software.

    PubMed

    Islami Parkoohi, Parisa; Zare, Hashem; Abdollahifard, Gholamreza

    2015-01-01

    Computerized preventive screening software is a cost effective intervention tool to address non-communicable chronic diseases. Shiraz Smart Screening Software (SSSS) was developed as an innovative tool for qualified screening. It allows simultaneous smart screening of several high-burden chronic diseases and supports reminder notification functionality. The extent in which SSSS affects screening quality is also described. Following software development, preventive screening and annual health examinations of 261 school staff (Medical School of Shiraz, Iran) was carried out in a software-assisted manner. To evaluate the quality of the software-assisted screening, we used quasi-experimental study design and determined coverage, irregular attendance and inappropriateness proportions in relation with the manual and software-assisted screening as well as the corresponding number of requested tests. In manual screening method, 27% of employees were covered (with 94% irregular attendance) while by software-assisted screening, the coverage proportion was 79% (attendance status will clear after the specified time). The frequency of inappropriate screening test requests, before the software implementation, was 41.37% for fasting plasma glucose, 41.37% for lipid profile, 0.84% for occult blood, 0.19% for flexible sigmoidoscopy/colonoscopy, 35.29% for Pap smear, 19.20% for mammography and 11.2% for prostate specific antigen. All of the above were corrected by the software application. In total, 366 manual screening and 334 software-assisted screening tests were requested. SSSS is an innovative tool to improve the quality of preventive screening plans in terms of increased screening coverage, reduction in inappropriateness and the total number of requested tests.

  8. Trade-off between benefit and harm is crucial in health screening recommendations. Part II: evidence summaries.

    PubMed

    Silvestre, Maria Asuncion A; Dans, Leonila F; Dans, Antonio L

    2011-03-01

    Evidence on the effectiveness of health screening strategies may be direct (i.e., studies on screening vs. no screening) or indirect (i.e., studies that separately evaluate the screening test[s], the confirmatory test, or the treatment). Critical trade-offs in the balance between harm and benefit for many screening strategies mandate that advocates of health screening adhere to the ethical precepts of nonmaleficence, autonomy, confidentiality, and equity. In our first article, we pointed out five prerequisites to justifying a health screening program: (1) the burden of illness should be high, (2) the screening and confirmatory tests should be accurate, (3) early treatment (or prevention) must be more effective than late treatment, (4) the tests and the treatment(s) must be safe, and (5) the cost of the screening strategy must be commensurate with the potential benefit. As can be gleaned from these criteria, recommendations on screening must be tailored to specific populations. Recommendations in one country, no matter how authoritative, cannot be generalized to apply to all other countries. Although accuracy, effectiveness, and safety data may be global (criteria 2-4), burden of illness and efficiency (criteria 1 and 5) will always vary from country to country. Rather than review various national guidelines, in this last article of our two-part series, we present evidence summaries to illustrate health screening. Our examples were selected to address special issues related to four situations-screening for cancer, risk factors for disease, genetic disorders, and infectious diseases. Copyright © 2011 Elsevier Inc. All rights reserved.

  9. 40 CFR 1060.525 - How do I test fuel systems for diurnal emissions?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 33 2014-07-01 2014-07-01 false How do I test fuel systems for diurnal... EQUIPMENT Test Procedures § 1060.525 How do I test fuel systems for diurnal emissions? Use the procedures of... emissions from the measured diurnal emissions if the fuel tank is preconditioned with diurnal test fuel as...

  10. 40 CFR 1060.525 - How do I test fuel systems for diurnal emissions?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 34 2012-07-01 2012-07-01 false How do I test fuel systems for diurnal... EQUIPMENT Test Procedures § 1060.525 How do I test fuel systems for diurnal emissions? Use the procedures of... emissions from the measured diurnal emissions if the fuel tank is preconditioned with diurnal test fuel as...

  11. 40 CFR 1060.525 - How do I test fuel systems for diurnal emissions?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 34 2013-07-01 2013-07-01 false How do I test fuel systems for diurnal... EQUIPMENT Test Procedures § 1060.525 How do I test fuel systems for diurnal emissions? Use the procedures of... emissions from the measured diurnal emissions if the fuel tank is preconditioned with diurnal test fuel as...

  12. The impact of age, sex and socioeconomic deprivation on outcomes in a colorectal cancer screening programme.

    PubMed

    Mansouri, David; McMillan, Donald C; Grant, Yasmin; Crighton, Emilia M; Horgan, Paul G

    2013-01-01

    Population-based colorectal cancer screening has been shown to reduce cancer specific mortality and is used across the UK. Despite evidence that older age, male sex and deprivation are associated with an increased incidence of colorectal cancer, uptake of bowel cancer screening varies across demographic groups. The aim of this study was to assess the impact of age, sex and deprivation on outcomes throughout the screening process. A prospectively maintained database, encompassing the first screening round of a faecal occult blood test screening programme in a single geographical area, was analysed. Overall, 395,096 individuals were invited to screening, 204,139 (52%) participated and 6079 (3%) tested positive. Of the positive tests, 4625 (76%) attended for colonoscopy and cancer was detected in 396 individuals (9%). Lower uptake of screening was associated with younger age, male sex and deprivation (all p<0.001). Only deprivation was associated with failure to proceed to colonoscopy following a positive test (p<0.001). Despite higher positivity rates in those that were more deprived (p<0.001), the likelihood of detecting cancer in those attending for colonoscopy was lower (8% most deprived vs 10% least deprived, p = 0.003). Individuals who are deprived are less likely to participate in screening, less likely to undergo colonoscopy and less likely to have cancer identified as a result of a positive test. Therefore, this study suggests that strategies aimed at improving participation of deprived individuals in colorectal cancer screening should be directed at all stages of the screening process and not just uptake of the test.

  13. Interval cancers in a guaiac-based colorectal cancer screening programme: Consequences on sensitivity.

    PubMed

    Blom, Johannes; Törnberg, Sven

    2017-09-01

    Objective To evaluate interval cancers in the population-based colorectal cancer screening programme of Stockholm/Gotland, Sweden. Methods From 2008, individuals aged 60-69 were invited to colorectal cancer screening using biennial guaiac-based faecal occult blood test (Hemoccult®). Interval cancers, defined as colorectal cancer among participants not diagnosed by the screening programme but registered in the Swedish cancer register, were evaluated by cross-checking the screening histories for all cancers in the region 2008-2012. Results Of 203,848 individuals from nine different birth cohorts who participated (∼60%), 4530 (2.2%) tested positive. All invited individuals were followed up for 24 months after invitation. The cancer register reported 557 colorectal cancer, 219 (39.3%) screen-detected cancers and 338 (60.7%) interval cancers, generating both test- and episode sensitivities of approximately 40% and an interval cancer-rate of 17.1/10,000 tests. Among individuals with positive tests without colorectal cancer diagnosed at work-up colonoscopy, 37 interval cancers (10.9%) occurred. There was statistically significant lower sensitivity in women, ranging 22.4-32.2%, compared with 43.2-52.0% in men. Age-group and tumour location were not strongly correlated to screen-detected cancer rates. The programme sensitivity increased by year (20.3-25.0%), with successively more colorectal cancers diagnosed within the expanding programme (11.6-16.2%). Conclusion Interval cancer is a quality indicator of a screening programme. As the interval cancer-rate determined in a well-organized population-based screening programme was actually higher than the screen-detected cancer rate, a change to a more sensitive screening test is indicated. The lower screen-detected cancers among women, and compliance and quality of work-up colonoscopies also need attention.

  14. Toxicology screen

    MedlinePlus

    ... Analgesics - screen; Antidepressants - screen; Narcotics - screen; Phenothiazines - screen; Drug abuse screen; Blood alcohol test ... poisoning) Complicated alcohol abstinence (delirium tremens) Delirium ... Fetal alcohol syndrome Intentional overdose Seizures Stroke ...

  15. Point-Counterpoint: Cervical Cancer Screening Should Be Done by Primary Human Papillomavirus Testing with Genotyping and Reflex Cytology for Women over the Age of 25 Years

    PubMed Central

    Zhao, Chengquan

    2015-01-01

    Screening for cervical cancer with cytology testing has been very effective in reducing cervical cancer in the United States. For decades, the approach was an annual Pap test. In 2000, the Hybrid Capture 2 human papillomavirus (HPV) test was approved by the U.S. Food and Drug Administration (FDA) for screening women who have atypical squamous cells of underdetermined significance (ASCUS) detected by Pap test to determine the need for colposcopy. In 2003, the FDA approved expanding the use of the test to include screening performed in conjunction with a Pap test for women over the age of 30 years, referred to as “cotesting.” Cotesting allows women to extend the testing interval to 3 years if both tests have negative results. In April of 2014, the FDA approved the use of an HPV test (the cobas HPV test) for primary cervical cancer screening for women over the age of 25 years, without the need for a concomitant Pap test. The approval recommended either colposcopy or a Pap test for patients with specific high-risk HPV types detected by the HPV test. This was based on the results of the ATHENA trial, which included more than 40,000 women. Reaction to this decision has been mixed. Supporters point to the fact that the primary-screening algorithm found more disease (cervical intraepithelial neoplasia 3 or worse [CIN3+]) and also found it earlier than did cytology or cotesting. Moreover, the positive predictive value and positive-likelihood ratio of the primary-screening algorithm were higher than those of cytology. Opponents of the decision prefer cotesting, as this approach detects more disease than the HPV test alone. In addition, the performance of this new algorithm has not been assessed in routine clinical use. Professional organizations will need to develop guidelines that incorporate this testing algorithm. In this Point-Counterpoint, Dr. Stoler explains why he favors the primary-screening algorithm, while Drs. Austin and Zhao explain why they prefer the cotesting approach to screening for cervical cancer. PMID:25948606

  16. Colorectal cancer prevention: adherence patterns and correlates of tests done for screening purposes within United States populations.

    PubMed

    Ata, Ashar; Elzey, Jared D; Insaf, Tabassum Z; Grau, Ana M; Stain, Steven C; Ahmed, Nasar U

    2006-01-01

    Studies exploring CRC testing prevalence and correlates within US populations have provided limited and sometimes conflicting information. The most recent national-level reports have described US usage of CRC tests but none have considered only those tests done specifically for screening reasons as an outcome variable. Using the NHIS 2000 sample of >or=50 year-old, we assessed screening behavior using an outcome variable accounting for (1) any combination of recommended tests (2) done within their respective time guidelines, and (3) specifically for screening purposes. Only 25.8% (95% CI: 24.9-26.7%) of the population reported getting a test done for screening purposes within the recommended time. Most (>85%) of the FOBTs and only about 60% of endoscopies were done for screening. Among those who had an endoscopy within the recommended time, Blacks were more likely than Whites to report screening as the purpose of the test. Hispanics had the lowest test usage irrespective of test time, reason or type. Hispanics were 50% (p<0.001) less likely to be adherent, and Blacks approximately 22% (p<0.01) less likely to be adherent, than Whites. After multivariate adjustment, differences between Whites and Blacks disappeared; Hispanics remained less likely. Increasing education predicted higher adherence among Whites but only undergraduate completion did so among Blacks. Male gender predicted adherence only among Blacks and insurance only among Hispanics. Preventive screening for CRC is lower than estimates from previous studies. Future studies should consider accounting for test purpose. Our findings need confirmation through studies based on objective data.

  17. Newborn screening for citrin deficiency and carnitine uptake defect using second-tier molecular tests.

    PubMed

    Wang, Li-Yun; Chen, Nien-I; Chen, Pin-Wen; Chiang, Shu-Chuan; Hwu, Wuh-Liang; Lee, Ni-Chung; Chien, Yin-Hsiu

    2013-02-10

    Tandem mass spectrometry (MS/MS) analysis is a powerful tool for newborn screening, and many rare inborn errors of metabolism are currently screened using MS/MS. However, the sensitivity of MS/MS screening for several inborn errors, including citrin deficiency (screened by citrulline level) and carnitine uptake defect (CUD, screened by free carnitine level), is not satisfactory. This study was conducted to determine whether a second-tier molecular test could improve the sensitivity of citrin deficiency and CUD detection without increasing the false-positive rate. Three mutations in the SLC25A13 gene (for citrin deficiency) and one mutation in the SLC22A5 gene (for CUD) were analyzed in newborns who demonstrated an inconclusive primary screening result (with levels between the screening and diagnostic cutoffs). The results revealed that 314 of 46 699 newborns received a second-tier test for citrin deficiency, and two patients were identified; 206 of 30 237 newborns received a second-tier testing for CUD, and one patient was identified. No patients were identified using the diagnostic cutoffs. Although the incidences for citrin deficiency (1:23 350) and CUD (1:30 000) detected by screening are still lower than the incidences calculated from the mutation carrier rates, the second-tier molecular test increases the sensitivity of newborn screening for citrin deficiency and CUD without increasing the false-positive rate. Utilizing a molecular second-tier test for citrin deficiency and carnitine transporter deficiency is feasible.

  18. Pre-screening Discussions and Prostate-Specific Antigen Testing for Prostate Cancer Screening

    PubMed Central

    Li, Jun; Zhao, Guixiang; Hall, Ingrid J.

    2015-01-01

    Introduction For many men, the net benefit of prostate cancer screening with prostate-specific antigen (PSA) tests may be small. Many major medical organizations have issued recommendations for prostate cancer screening, stressing the need for shared decision making before ordering a test. The purpose of this study is to better understand associations between discussions about benefits and harms of PSA testing and uptake of the test among men aged ≥40 years. Methods Associations between pre-screening discussions and PSA testing were examined using self-reported data from the 2012 Behavioral Risk Factor Surveillance System. Unadjusted prevalence of PSA testing was estimated and AORs were calculated using logistic regression in 2014. Results The multivariate analysis showed that men who had ever discussed advantages of PSA testing only or discussed both advantages and disadvantages were more likely, respectively, to report having had a test within the past year than men who had no discussions (p<0.001). In addition, men who had only discussed the disadvantages of PSA testing with their healthcare providers were more likely (AOR=2.75, 95% CI=2.00, 3.79) to report getting tested than men who had no discussions. Conclusions Discussions of the benefits or harms of PSA testing are positively associated with increased uptake of the test. Given the conflicting recommendations for prostate cancer screening and increasing importance of shared decision making, this study points to the need for understanding how pre-screening discussions are being conducted in clinical practice and the role played by patients’ values and preferences in decisions about PSA testing. PMID:25997905

  19. Pre-screening Discussions and Prostate-Specific Antigen Testing for Prostate Cancer Screening.

    PubMed

    Li, Jun; Zhao, Guixiang; Hall, Ingrid J

    2015-08-01

    For many men, the net benefit of prostate cancer screening with prostate-specific antigen (PSA) tests may be small. Many major medical organizations have issued recommendations for prostate cancer screening, stressing the need for shared decision making before ordering a test. The purpose of this study is to better understand associations between discussions about benefits and harms of PSA testing and uptake of the test among men aged ≥40 years. Associations between pre-screening discussions and PSA testing were examined using self-reported data from the 2012 Behavioral Risk Factor Surveillance System. Unadjusted prevalence of PSA testing was estimated and AORs were calculated using logistic regression in 2014. The multivariate analysis showed that men who had ever discussed advantages of PSA testing only or discussed both advantages and disadvantages were more likely, respectively, to report having had a test within the past year than men who had no discussions (p<0.001). In addition, men who had only discussed the disadvantages of PSA testing with their healthcare providers were more likely (AOR=2.75, 95% CI=2.00, 3.79) to report getting tested than men who had no discussions. Discussions of the benefits or harms of PSA testing are positively associated with increased uptake of the test. Given the conflicting recommendations for prostate cancer screening and increasing importance of shared decision making, this study points to the need for understanding how pre-screening discussions are being conducted in clinical practice and the role played by patients' values and preferences in decisions about PSA testing. Published by Elsevier Inc.

  20. Test, episode, and programme sensitivities of screening for colorectal cancer as a public health policy in Finland: experimental design.

    PubMed

    Malila, Nea; Oivanen, Tiina; Malminiemi, Outi; Hakama, Matti

    2008-11-20

    To report the sensitivities of the faecal occult blood test, screening episode, and screening programme for colorectal cancer and the benefits of applying a randomised design at the implementation phase of a new public health policy. Experimental design incorporated in public health evaluation using randomisation at individual level in the target population. 161 of the 431 Finnish municipalities in 2004-6. 106 000 adults randomised to screening or control arms. In total, 52 998 adults aged 60-64 in the screening arm received faecal occult blood test kits. Test, episode, and programme sensitivities estimated by the incidence method and corrected for selective attendance and overdiagnosis. The response for screening was high overall (70.8%), and significantly better in women (78.1%) than in men (63.3%). The incidence of cancer in the controls was somewhat higher in men than in women (103 v 93 per 100 000 person years), which was not true for interval cancers (42 v 49 per 100 000 person years). The sensitivity of the faecal occult blood test was 54.6%. Only a few interval cancers were detected among those with positive test results, hence the episode sensitivity of 51.3% was close to the test sensitivity. At the population level the sensitivity of the programme was 37.5%. Although relatively low, the sensitivity of screening for colorectal cancer with the faecal occult blood test in Finland was adequate. An experimental design is a prerequisite for evaluation of such a screening programme because the effectiveness of preventing deaths is likely to be small and results may otherwise remain inconclusive. Thus, screening for colorectal cancer using any primary test modality should be launched in a public health programme with randomisation of the target population at the implementation phase.

  1. Small-area variation in screening for cancer, glucose and cholesterol in Ontario: a cross-sectional study.

    PubMed

    Fernandes, Kimberly A; Sutradhar, Rinku; Borkhoff, Cornelia M; Baxter, Nancy; Lofters, Aisha; Rabeneck, Linda; Tinmouth, Jill; Paszat, Lawrence

    2015-01-01

    Screening for cervical, breast and colon cancers, and elevations of cholesterol and glucose, reduces premature cause-specific mortality from these cancers and circulatory diseases. Despite primary care reforms and incentives, and promotion of cancer-screening programs among individuals, participation is suboptimal. We aimed to examine participation as of Dec. 31, 2011, by factors of deprivation, demographics and primary care at the small-area level. From health care administrative databases, we identified people eligible for each screening test, and their participation, in each dissemination area (referred to as small areas, n = 18 950) in Ontario. We calculated rates for each test among small areas (overall and stratified by demographic, socioeconomic and primary care descriptors) and stratified by sex for all tests combined. We loaded all data into a geographic information system. Funnel plots were generated showing the percentage of eligible people who completed screening for all tests by small area, stratified by sex. Overall and stratified screening prevalence ratios were calculated among small areas. Among small areas, the mean and SD for participation in all tests combined was 31.6% (SD 11.0%) for women and 41.2% (SD 12.0%) for men. Screening prevalence among small areas, for each test and for all tests combined, overall and stratified by sex, declined with decreasing percentage with high school completion, decreasing socioeconomic quintile, and decreasing percentage with an identifiable primary care physician. Our results show that the rate of participation in all eligible screening tests among small areas is much lower than the rate of participation in any one particular test. This finding has implications for the design and implementation of strategies to improve rates of screening.

  2. Cost and Efficacy Assessment of an Alternative Medication Compliance Urine Drug Testing Strategy.

    PubMed

    Doyle, Kelly; Strathmann, Frederick G

    2017-02-01

    This study investigates the frequency at which quantitative results provide additional clinical benefit compared to qualitative results alone. A comparison between alternative urine drug screens and conventional screens including the assessment of cost-to-payer differences, accuracy of prescription compliance or polypharmacy/substance abuse was also included. In a reference laboratory evaluation of urine specimens from across the United States, 213 urine specimens with provided prescription medication information (302 prescriptions) were analyzed by two testing algorithms: 1) conventional immunoassay screen with subsequent reflexive testing of positive results by quantitative mass spectrometry; and 2) a combined immunoassay/qualitative mass-spectrometry screen that substantially reduced the need for subsequent testing. The qualitative screen was superior to immunoassay with reflex to mass spectrometry in confirming compliance per prescription (226/302 vs 205/302), and identifying non-prescription abuse (97 vs 71). Pharmaceutical impurities and inconsistent drug metabolite patterns were detected in only 3.8% of specimens, suggesting that quantitative results have limited benefit. The percentage difference between the conventional testing algorithm and the alternative screen was projected to be 55%, and a 2-year evaluation of test utilization as a measure of test order volume follows an exponential trend for alternative screen test orders over conventional immunoassay screens that require subsequent confirmation testing. Alternative, qualitative urine drug screens provide a less expensive, faster, and more comprehensive evaluation of patient medication compliance and drug abuse. The vast majority of results were interpretable with qualitative results alone indicating a reduced need to automatically reflex to quantitation or provide quantitation for the majority of patients. This strategy highlights a successful approach using an alternative strategy for both the laboratory and physician to align clinical needs while being mindful of costs.

  3. Systems of support to increase colorectal cancer screening and follow-up rates (SOS): design, challenges, and baseline characteristics of trial participants.

    PubMed

    Green, Beverly B; Wang, C Y; Horner, Kathryn; Catz, Sheryl; Meenan, Richard T; Vernon, Sally W; Carrell, David; Chubak, Jessica; Ko, Cynthia; Laing, Sharon; Bogart, Andy

    2010-11-01

    Screening decreases colorectal cancer (CRC) morbidity and mortality, yet remains underutilized. Screening breakdowns arise from lack of uptake and failure to follow-up after a positive screening test. Systems of support to increase colorectal cancer screening and follow-up (SOS) is a randomized trial designed to increase: (1) CRC screening and (2) follow-up of positive screening tests. The Chronic Care Model and the Preventive Health Model inform study design. The setting is a large nonprofit healthcare organization. In part-1 study, patients age 50-75 due for CRC screening are randomized to one of 4 study conditions. Arm 1 receives usual care. Arm 2 receives automated support (mailed information about screening choices and fecal occult blood tests (FOBT)). Arm 3 receives automated and assisted support (a medical assistant telephone call). Arm 4 receives automated, assisted, and care management support (a registered nurse provides behavioral activation and coordination of care). In part-2, study patients with a positive FOBT or adenomas on flexible sigmoidoscopy are randomized to receive either usual care or nurse care management. Primary outcomes are: 1) the proportion with CRC screening, 2) the proportion with a complete diagnostic evaluation after a positive screening test. We sent recruitment letters to 15,414 patients and 4675 were randomized. Randomly assigned treatment groups were similar in age, sex, race, education, self-reported health, and CRC screening history. We will determine the effectiveness and cost effectiveness of stepped increases in systems of support to increase CRC screening and follow-up after a positive screening test over 2years. Copyright © 2010 Elsevier Inc. All rights reserved.

  4. 40 CFR 86.1439 - Certification Short Test emission test procedures-EPA.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 20 2013-07-01 2013-07-01 false Certification Short Test emission test procedures-EPA. 86.1439 Section 86.1439 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES (CONTINUED) Emission Regulations for New...

  5. 40 CFR 86.1360-2007 - Supplemental emission test; test cycle and procedures.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 20 2012-07-01 2012-07-01 false Supplemental emission test; test cycle and procedures. 86.1360-2007 Section 86.1360-2007 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES (CONTINUED) Emission Regulations...

  6. 40 CFR 86.1439 - Certification Short Test emission test procedures-EPA.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 20 2012-07-01 2012-07-01 false Certification Short Test emission test procedures-EPA. 86.1439 Section 86.1439 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES (CONTINUED) Emission Regulations for New...

  7. 40 CFR 86.1360-2007 - Supplemental emission test; test cycle and procedures.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 20 2013-07-01 2013-07-01 false Supplemental emission test; test cycle and procedures. 86.1360-2007 Section 86.1360-2007 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES (CONTINUED) Emission Regulations...

  8. Disability and Preventive Cancer Screening: Results from the 2001 California Health Interview Survey

    PubMed Central

    Ramirez, Anthony; Farmer, Gail C.; Grant, David; Papachristou, Theodora

    2005-01-01

    Objective. We sought to evaluate preventive cancer screening compliance among adults with disability in California. Methods. We used data from the 2001 California Health Interview Survey to compare disabled and nondisabled adults for differences in preventive cancer screening behaviors. Compliance rates for cancer screening tests (mammography, Papanicolaou test, prostate-specific antigen, sigmoidoscopy/colonoscopy, and fecal occult blood test) between the 2 subpopulations were evaluated. Results. Women with disabilities were 17% (Papanicolaou tests) and 13% (mammograms) more likely than women without disabilities to report noncompliance with cancer screening guidelines. Interactions between disability and reports of a doctor recommendation on cervical cancer screening were significant; women with disabilities had a lower likelihood of receiving a recommendation. Men with disabilities were 19% less likely than men without disabilities to report a prostate-specific antigen test within the last 3 years. Conclusions.secondary to structural and/or clinical factors underpinning the differences found. PMID:16195509

  9. Assessing Auditory Processing Abilities in Typically Developing School-Aged Children.

    PubMed

    McDermott, Erin E; Smart, Jennifer L; Boiano, Julie A; Bragg, Lisa E; Colon, Tiffany N; Hanson, Elizabeth M; Emanuel, Diana C; Kelly, Andrea S

    2016-02-01

    Large discrepancies exist in the literature regarding definition, diagnostic criteria, and appropriate assessment for auditory processing disorder (APD). Therefore, a battery of tests with normative data is needed. The purpose of this study is to collect normative data on a variety of tests for APD on children aged 7-12 yr, and to examine effects of outside factors on test performance. Children aged 7-12 yr with normal hearing, speech and language abilities, cognition, and attention were recruited for participation in this normative data collection. One hundred and forty-seven children were recruited using flyers and word of mouth. Of the participants recruited, 137 children qualified for the study. Participants attended schools located in areas that varied in terms of socioeconomic status, and resided in six different states. Audiological testing included a hearing screening (15 dB HL from 250 to 8000 Hz), word recognition testing, tympanometry, ipsilateral and contralateral reflexes, and transient-evoked otoacoustic emissions. The language, nonverbal IQ, phonological processing, and attention skills of each participant were screened using the Clinical Evaluation of Language Fundamentals-4 Screener, Test of Nonverbal Intelligence, Comprehensive Test of Phonological Processing, and Integrated Visual and Auditory-Continuous Performance Test, respectively. The behavioral APD battery included the following tests: Dichotic Digits Test, Frequency Pattern Test, Duration Pattern Test, Random Gap Detection Test, Compressed and Reverberated Words Test, Auditory Figure Ground (signal-to-noise ratio of +8 and +0), and Listening in Spatialized Noise-Sentences Test. Mean scores and standard deviations of each test were calculated, and analysis of variance tests were used to determine effects of factors such as gender, handedness, and birth history on each test. Normative data tables for the test battery were created for the following age groups: 7- and 8-yr-olds (n = 49), 9- and 10-yr-olds (n = 40), and 11- and 12-yr-olds (n = 48). No significant effects were seen for gender or handedness on any of the measures. The data collected in this study are appropriate for use in clinical diagnosis of APD. Use of a low-linguistically loaded core battery with the addition of more language-based tests, when language abilities are known, can provide a well-rounded picture of a child's auditory processing abilities. Screening for language, phonological processing, attention, and cognitive level can provide more information regarding a diagnosis of APD, determine appropriateness of the test battery for the individual child, and may assist with making recommendations or referrals. It is important to use a multidisciplinary approach in the diagnosis and treatment of APD due to the high likelihood of comorbidity with other language, learning, or attention deficits. Although children with other diagnoses may be tested for APD, it is important to establish previously made diagnoses before testing to aid in appropriate test selection and recommendations. American Academy of Audiology.

  10. Implications of false-positive results for future cancer screenings.

    PubMed

    Taksler, Glen B; Keating, Nancy L; Rothberg, Michael B

    2018-06-01

    False-positive cancer screening results may affect a patient's willingness to obtain future screening. The authors conducted logistic regression analysis of 450,484 person-years of electronic medical records (2006-2015) in 92,405 individuals aged 50 to 75 years. Exposures were false-positive breast, prostate, or colorectal cancer screening test results (repeat breast imaging or negative breast biopsy ≤3 months after screening mammography, repeat prostate-specific antigen [PSA] test ≤3 months after PSA test result ≥4.0 ng/mL or negative prostate biopsy ≤3 months after any PSA result, or negative colonoscopy [without biopsy/polypectomy] ≤6 months after a positive fecal occult blood test). Outcomes were up-to-date status with breast or colorectal cancer screening. Covariates included prior screening history, clinical information (eg, family history, obesity, and smoking status), comorbidity, and demographics. Women were more likely to be up to date with breast cancer screening if they previously had false-positive mammography findings (adjusted odds ratio [AOR], 1.43 [95% confidence interval, 1.34-1.51] without breast biopsy and AOR, 2.02 [95% confidence interval, 1.56-2.62] with breast biopsy; both P<.001). The same women were more likely to be up to date with colorectal cancer screening (AOR range, 1.25-1.47 depending on breast biopsy; both P<.001). Men who previously had false-positive PSA testing were more likely to be up to date with colorectal cancer screening (AOR, 1.22 [P = .039] without prostate imaging/biopsy and AOR, 1.60 [P = .028] with imaging/biopsy). Results were stronger for individuals with more false-positive results (all P≤.005). However, women with previous false-positive colorectal cancer fecal occult blood test screening results were found to be less likely to be up to date with breast cancer screening (AOR, 0.73; P<.001). Patients who previously had a false-positive breast or prostate cancer screening test were more likely to engage in future screening. Cancer 2018;124:2390-8. © 2018 American Cancer Society. © 2018 American Cancer Society.

  11. 40 CFR 89.119 - Emission tests.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 21 2013-07-01 2013-07-01 false Emission tests. 89.119 Section 89.119... Provisions § 89.119 Emission tests. (a) Manufacturer testing. (1) Upon completion of service accumulation, the manufacturer must test each test engine using the specified test procedures, except as provided in...

  12. 40 CFR 89.119 - Emission tests.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 20 2014-07-01 2013-07-01 true Emission tests. 89.119 Section 89.119... Provisions § 89.119 Emission tests. (a) Manufacturer testing. (1) Upon completion of service accumulation, the manufacturer must test each test engine using the specified test procedures, except as provided in...

  13. Evaluation of Five Chromogenic Agar Media and the Rosco Rapid Carb Screen Kit for Detection and Confirmation of Carbapenemase Production in Gram-Negative Bacilli

    PubMed Central

    Gilmour, Matthew W.; DeGagne, Pat; Nichol, Kim; Karlowsky, James A.

    2014-01-01

    An efficient workflow to screen for and confirm the presence of carbapenemase-producing Gram-negative bacilli was developed by evaluating five chromogenic screening agar media and two confirmatory assays, the Rapid Carb screen test (Rosco Diagnostica A/S, Taastrup, Denmark) and the modified Hodge test. A panel of 150 isolates was used, including 49 carbapenemase-producing isolates representing a variety of β-lactamase enzyme classes. An evaluation of analytical performance, assay cost, and turnaround time indicated that the preferred workflow (screening test followed by confirmatory testing) was the chromID Carba agar medium (bioMérieux, Marcy l'Étoile, France), followed by the Rapid Carb screen test, yielding a combined sensitivity of 89.8% and a specificity of 100%. As an optional component of the workflow, a determination of carbapenemase gene class via molecular means could be performed subsequent to confirmatory testing. PMID:25355764

  14. Hog Charm II tetracycline test screening results compared with a liquid chromatography tandem mass spectrometry 10-μg/kg method.

    PubMed

    Salter, Robert; Holmes, Steven; Legg, David; Coble, Joel; George, Bruce

    2012-02-01

    Pork tissue samples that tested positive and negative by the Charm II tetracycline test screening method in the slaughter plant laboratory were tested with the modified AOAC International liquid chromatography tandem mass spectrometry (LC-MS-MS) method 995.09 to determine the predictive value of the screening method at detecting total tetracyclines at 10 μg/kg of tissue, in compliance with Russian import regulations. There were 218 presumptive-positive tetracycline samples of 4,195 randomly tested hogs. Of these screening test positive samples, 83% (182) were positive, >10 μg/kg by LC-MS-MS; 12.8% (28) were false violative, greater than limit of detection (LOD) but <10 μg/kg; and 4.2% (8) were not detected at the LC-MS-MS LOD. The 36 false-violative and not-detected samples represent 1% of the total samples screened. Twenty-seven of 30 randomly selected tetracycline screening negative samples tested below the LC-MS-MS LOD, and 3 samples tested <3 μg/kg chlortetracycline. Results indicate that the Charm II tetracycline test is effective at predicting hogs containing >10 μg/kg total tetracyclines in compliance with Russian import regulations.

  15. Assessing patients' attitudes to opt-out HIV rapid screening in community dental clinics: a cross-sectional Canadian experience.

    PubMed

    Brondani, Mario; Chang, Steve; Donnelly, Leeann

    2016-05-10

    As a public health initiative, provided-initiated HIV screening test in dental settings has long been available in the U.S.; it was only in 2011 that such setting was used in Canada. The objective of this paper was to assess patients' response to, and attitudes towards, an opt-out rapid HIV screening test in a dental setting in Vancouver, Canada. A cross-sectional evaluation design using a self-complete survey questionnaire on self-perceived values and benefits of an opt-out rapid HIV screening was employed. An anonymous 10-item questionnaire was developed to explore reasons for accepting or declining the HIV rapid screening test, and barriers and facilitators for the HIV screening in dental settings. Eligible participants were male and female older than 19 years attending community dental clinics and who were offered the HIV screening test between June 2010 and February 2015. From the 1552 age-eligible patients, 519 completed the survey and 155 (10 %) accepted the HIV screening due to its convenience, and/or free cost, and/or instant results. From the 458 respondents who did not accept the screening, 362 (79 %) were between the ages of 25 and 45 years; 246 (53.7 %) had identifiable risk factors for contracting HIV; and 189 (41.3 %) reported having been tested within the last 3 months. Those tested in less than 3 months had 3.5 times higher odds to decline the HIV screening compared to those who have been tested between 3 months and 1 year. Convenience, cost-free and readily available results are factors influencing rapid HIV screening uptake. Although dental settings remain an alternative venue for HIV screening from the patients' perspectives, dental hygiene settings might offer a better option.

  16. Screening for Colorectal Cancer: US Preventive Services Task Force Recommendation Statement.

    PubMed

    Bibbins-Domingo, Kirsten; Grossman, David C; Curry, Susan J; Davidson, Karina W; Epling, John W; García, Francisco A R; Gillman, Matthew W; Harper, Diane M; Kemper, Alex R; Krist, Alex H; Kurth, Ann E; Landefeld, C Seth; Mangione, Carol M; Owens, Douglas K; Phillips, William R; Phipps, Maureen G; Pignone, Michael P; Siu, Albert L

    2016-06-21

    Colorectal cancer is the second leading cause of cancer death in the United States. In 2016, an estimated 134,000 persons will be diagnosed with the disease, and about 49,000 will die from it. Colorectal cancer is most frequently diagnosed among adults aged 65 to 74 years; the median age at death from colorectal cancer is 68 years. To update the 2008 US Preventive Services Task Force (USPSTF) recommendation on screening for colorectal cancer. The USPSTF reviewed the evidence on the effectiveness of screening with colonoscopy, flexible sigmoidoscopy, computed tomography colonography, the guaiac-based fecal occult blood test, the fecal immunochemical test, the multitargeted stool DNA test, and the methylated SEPT9 DNA test in reducing the incidence of and mortality from colorectal cancer or all-cause mortality; the harms of these screening tests; and the test performance characteristics of these tests for detecting adenomatous polyps, advanced adenomas based on size, or both, as well as colorectal cancer. The USPSTF also commissioned a comparative modeling study to provide information on optimal starting and stopping ages and screening intervals across the different available screening methods. The USPSTF concludes with high certainty that screening for colorectal cancer in average-risk, asymptomatic adults aged 50 to 75 years is of substantial net benefit. Multiple screening strategies are available to choose from, with different levels of evidence to support their effectiveness, as well as unique advantages and limitations, although there are no empirical data to demonstrate that any of the reviewed strategies provide a greater net benefit. Screening for colorectal cancer is a substantially underused preventive health strategy in the United States. The USPSTF recommends screening for colorectal cancer starting at age 50 years and continuing until age 75 years (A recommendation). The decision to screen for colorectal cancer in adults aged 76 to 85 years should be an individual one, taking into account the patient's overall health and prior screening history (C recommendation).

  17. 40 CFR 51.358 - Test equipment.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 2 2014-07-01 2014-07-01 false Test equipment. 51.358 Section 51.358....358 Test equipment. Computerized emission test systems are required for performing an official emissions test on subject vehicles. (a) Performance features of computerized emission test systems. The...

  18. 40 CFR 86.1829-01 - Durability and emission testing requirements; waivers.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... manufacturer's engineering evaluation of appropriate high-altitude emission testing, all light-duty vehicles... tests, development tests, or other appropriate information and good engineering judgment. (B) In lieu of... emission tests, development tests, or other appropriate information and good engineering judgment. (C) A...

  19. 40 CFR 51.358 - Test equipment.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 2 2010-07-01 2010-07-01 false Test equipment. 51.358 Section 51.358....358 Test equipment. Computerized emission test systems are required for performing an official emissions test on subject vehicles. (a) Performance features of computerized emission test systems. The...

  20. Plasma Septin9 versus fecal immunochemical testing for colorectal cancer screening: a prospective multicenter study.

    PubMed

    Johnson, David A; Barclay, Robert L; Mergener, Klaus; Weiss, Gunter; König, Thomas; Beck, Jürgen; Potter, Nicholas T

    2014-01-01

    Screening improves outcomes related to colorectal cancer (CRC); however, suboptimal participation for available screening tests limits the full benefits of screening. Non-invasive screening using a blood based assay may potentially help reach the unscreened population. To compare the performance of a new Septin9 DNA methylation based blood test with a fecal immunochemical test (FIT) for CRC screening. In this trial, fecal and blood samples were obtained from enrolled patients. To compare test sensitivity for CRC, patients with screening identified colorectal cancer (n = 102) were enrolled and provided samples prior to surgery. To compare test specificity patients were enrolled prospectively (n = 199) and provided samples prior to bowel preparation for screening colonoscopy. Plasma and fecal samples were analyzed using the Epi proColon and OC Fit-Check tests respectively. For all samples, sensitivity for CRC detection was 73.3% (95% CI 63.9-80.9%) and 68.0% (95% CI 58.2-76.5%) for Septin9 and FIT, respectively. Specificity of the Epi proColon test was 81.5% (95% CI 75.5-86.3%) compared with 97.4% (95% CI 94.1-98.9%) for FIT. For paired samples, the sensitivity of the Epi proColon test (72.2% -95% CI 62.5-80.1%) was shown to be statistically non-inferior to FIT (68.0%-95% CI 58.2-76.5%). When test results for Epi proColon and FIT were combined, CRC detection was 88.7% at a specificity of 78.8%. At a sensitivity of 72%, the Epi proColon test is non- inferior to FIT for CRC detection, although at a lower specificity. With negative predictive values of 99.8%, both methods are identical in confirming the absence of CRC. ClinicalTrials.gov NCT01580540.

  1. Enhancing HIV Testing and Treatment among Men Who Have Sex with Men in China: A Pilot Model with Two-Rapid Tests, Single Blood Draw Session, and Intensified Case Management in Six Cities in 2013.

    PubMed

    Zhang, Dapeng; Lu, Hongyan; Zhuang, Minghua; Wu, Guohui; Yan, Hongjing; Xu, Jun; Wei, Xiaoli; Li, Chengmei; Meng, Sining; Fu, Xiaojing; Qi, Jinlei; Wang, Peng; Luo, Mei; Dai, Min; Yip, Ray; Sun, Jiangping; Wu, Zunyou

    2016-01-01

    To explore models to improve HIV testing, linkage to care and treatment among men who have sex with men (MSM) in cooperation with community-based organizations (CBOs) in China. We introduced a new model for HIV testing services targeting MSM in six cities in 2013.These models introduced provision of rapid HIV testing by CBO staff and streamlined processes for HIV screening, confirmation of initial reactive screening results, and linkage to care among diagnosed people. We monitored attrition along each step of the continuum of care from screening to treatment and compared program performance between 2012 and 2013. According to the providers of two rapid tests (HIV screening), four different services delivery models were examined in 2013: Model A = first screen at CDC, second at CDC (Model A = CDC+CDC), Model B = first and second screens at CBOs (Model B = CBO+CBO), Model C = first screen at CBO, second at Hospital (Model C = CBO+Hosp), and Model D = first screen at CBO, second at CDC (Model D = CBO+CDC). Logistic regressions were performed to assess advantages of different screening models of case finding and case management. Compared to 2012, the number of HIV screening tests performed for MSM increased 35.8% in 2013 (72,577 in 2013 vs. 53,455 in 2012). We observed a 5.6% increase in proportion of cases screened reactive receiving HIV confirmatory tests (93.9% in 2013 vs. 89.2% in 2012, χ2 = 48.52, p<0.001) and 65% reduction in loss to CD4 cell count tests (15% in 2013 vs. 43% in 2012, χ2 = 628.85, p<0.001). Regarding linkage to care and treatment, the 2013 pilot showed that the Model D had the highest rate of loss between screening reactive and confirmatory test among the four models, with 18.1% fewer receiving a second screening test and a further 5.9% loss among those receiving HIV confirmatory tests. The Model B and the Model C showed lower losses (0.8% and 1.3%) for newly diagnosed HIV positives receiving CD4 cell count tests, and higher rates of HIV positives referred to designated ART hospitals (88.0% and 93.3%) than the Model A and Model D (4.6% and 5.7% for CD4 cell count test, and 68.9% and 64.4% for referring to designated ART hospitals). The proportion of cases where the screening test was reactive that were commenced on ART was highest in Model C; 52.8% of cases commenced on ART compared to 38.9%, 34.2% and 21.1% in Models A, B and D respectively. Using Model A as a reference group, the multivariate logistic regression results also showed the advantages of Models B, C and D, which increased CD4 cell count test, referral to designated ART hospitals and initiation of ART, when controlling for program city and other factors. This study has demonstrated that involvement of CBOs in HIV rapid testing provision, streamlining testing and care procedures and early hospital case management can improve testing, linkage to, and retention in care and treatment among MSM in China.

  2. Development of an Attitudes Measure for Prenatal Screening in Diverse Populations

    ERIC Educational Resources Information Center

    Posner, S. F.; Learman, L. A.; Gates, E. A.; Washington, A. E.; Kuppermann, M.

    2004-01-01

    Background: Prenatal screening for chromosomal abnormalities is routinely offered to all pregnant women who present for care by their 20th gestational week. Not all women, however, choose to undergo one of these tests, and choice of which test(s) to undergo also vary. The reasons for variation in screening test behavior have not been fully…

  3. Performance Characteristics of the Reverse Syphilis Screening Algorithm in a Population With a Moderately High Prevalence of Syphilis.

    PubMed

    Rourk, Angela R; Nolte, Frederick S; Litwin, Christine M

    2016-11-01

    With the recent introduction of automated treponemal tests, a new reverse syphilis algorithm has been proposed and now used by many clinical laboratories. We analyzed the impact of instituting the reverse screening syphilis algorithm in a laboratory that serves a geographic area with a moderately high prevalence of syphilis infection. Serum samples sent for syphilis testing were tested using a treponemal enzyme immunoassay (EIA) as the screening assay. EIA reactive samples were tested by rapid plasma reagin (RPR) and titered to end point if reactive. RPR nonreactive samples were analyzed by the Treponema pallidum particle agglutination test (TP-PA). Pertinent medical records were reviewed for false-reactive screens and samples with evidence of past syphilis infection. Among 10,060 patients tested, 502 (5%) were reactive on the initial EIA screen. The RPR was reactive in 150 (1.5%). TP-PA testing determined that 103 (1.0%) were falsely reactive on initial EIA screen. The reverse screening algorithm, however, identified 242 (2.4%) with evidence of latent, secondary, or past syphilis, 21 of whom had no or unknown prior treatment with antibiotics. Despite a 1.0% false-reactive rate, the reverse syphilis algorithm detected 21 patients with possible latent syphilis that may have gone undetected by traditional syphilis screening. © American Society for Clinical Pathology, 2016. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  4. An audit of the cervical cancer screening histories of 246 women with carcinoma.

    PubMed

    Duggan, Máire A; Nation, Jill

    2012-07-01

    Women with cervical carcinoma and residing in the Calgary Health Region between 1996 and 2001 were audited to characterize factors in the opportunistic cervical cancer screening pathway contributing to screening failures. The cohort consisted of 246 women. Information on their Pap tests and colposcopic/gynecologic examinations was obtained from the files of Calgary Laboratory Services and their colposcopic/cancer center treatment charts. Screening failure factors were defined, and frequencies were calculated. Screening failure factors were as follows: (1) 41 (16.7%) were not screened, that is, no Pap test screening; (2) 29 (11.8%) were underscreened, that is, no Pap test within 12 months of diagnosis; (3) 28 (13.7%) were undersampled, that is, the Pap test result was negative; (4) 34 (13.8%) had no referral for a colposcopy/gynecology examination, and/or it was delayed for more than 3 months; (5) 18 (13.2%) had delayed referral for examination of an atypical glandular cell-high-grade squamous intraepithelial lesion and higher Pap test for more than 3 months; and (6) 73 (55.3%) were underdiagnosed, that is, the diagnosis in colposcopy examination was less than malignant. Underreported Pap tests and delayed Pap test reporting could not be fully investigated, but limited evidence suggested that underreporting contributed to some failures. Factors other than recruitment to cytological screening need targeted improvement if the region's cervical cancer prevention program is to be more effective.

  5. How to improve colon cancer screening rates

    PubMed Central

    Alberti, Luiz Ronaldo; Garcia, Diego Paim Carvalho; Coelho, Debora Lucciola; De Lima, David Correa Alves; Petroianu, Andy

    2015-01-01

    Colorectal carcinoma is a common cause of death throughout the world and may be prevented by routine control, which can detect precancerous neoplasms and early cancers before they undergo malignant transformation or metastasis. Three strategies may improve colon cancer screening rates: convince the population about the importance of undergoing a screening test; achieve higher efficacy in standard screening tests and make them more available to the community and develop new more sensitive and efficacious screening methods and make them available as routine tests. In this light, the present study seeks to review these three means through which to increase colon cancer screening rates. PMID:26688708

  6. Screening for colorectal cancer.

    PubMed

    He, Jin; Efron, Jonathan E

    2011-01-01

    March is national colorectal cancer awareness month. It is estimated that as many as 60% of colorectal cancer deaths could be prevented if all men and women aged 50 years or older were screened routinely. In 2000, Katie Couric's televised colonoscopy led to a 20% increase in screening colonoscopies across America, a stunning rise called the "Katie Couric Effect". This event demonstrated how celebrity endorsement affects health behavior. Currently, discussion is ongoing about the optimal strategy for CRC screening, particularly the costs of screening colonoscopy. The current CRC screening guidelines are summarized in Table 2. Debates over the optimum CRC screening test continue in the face of evidence that 22 million Americans aged 50 to 75 years are not screened for CRC by any modality and 25,000 of those lives may have been saved if they had been screened for CRC. It is clear that improving screening rates and reducing disparities in underscreened communities and population subgroups could further reduce colorectal cancer morbidity and mortality. National Institutes of Health consensus identified the following priority areas to enhance the use and quality of colorectal cancer screening: Eliminate financial barriers to colorectal cancer screening and appropriate follow-up of positive results of colorectal cancer screening. Develop systems to ensure the high quality of colorectal cancer screening programs. Conduct studies to determine the comparative effectiveness of the various colorectal cancer screening methods in usual practice settings. Encouraging population adherence to screening tests and allowing patients to select the tests they prefer may do more good (as long as they choose something) than whatever procedure is chosen by the medical profession as the preferred test.

  7. 40 CFR 80.49 - Fuels to be used in augmenting the complex emission model through vehicle testing.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... complex emission model through vehicle testing. 80.49 Section 80.49 Protection of Environment... Reformulated Gasoline § 80.49 Fuels to be used in augmenting the complex emission model through vehicle testing... augmenting the complex emission model with a parameter not currently included in the complex emission model...

  8. 40 CFR 80.49 - Fuels to be used in augmenting the complex emission model through vehicle testing.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... complex emission model through vehicle testing. 80.49 Section 80.49 Protection of Environment... Reformulated Gasoline § 80.49 Fuels to be used in augmenting the complex emission model through vehicle testing... augmenting the complex emission model with a parameter not currently included in the complex emission model...

  9. 40 CFR 80.49 - Fuels to be used in augmenting the complex emission model through vehicle testing.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... complex emission model through vehicle testing. 80.49 Section 80.49 Protection of Environment... Reformulated Gasoline § 80.49 Fuels to be used in augmenting the complex emission model through vehicle testing... augmenting the complex emission model with a parameter not currently included in the complex emission model...

  10. 40 CFR 80.49 - Fuels to be used in augmenting the complex emission model through vehicle testing.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... complex emission model through vehicle testing. 80.49 Section 80.49 Protection of Environment... Reformulated Gasoline § 80.49 Fuels to be used in augmenting the complex emission model through vehicle testing... augmenting the complex emission model with a parameter not currently included in the complex emission model...

  11. Colorectal Cancer Screening in Average Risk Populations: Evidence Summary.

    PubMed

    Tinmouth, Jill; Vella, Emily T; Baxter, Nancy N; Dubé, Catherine; Gould, Michael; Hey, Amanda; Ismaila, Nofisat; McCurdy, Bronwen R; Paszat, Lawrence

    2016-01-01

    Introduction. The objectives of this systematic review were to evaluate the evidence for different CRC screening tests and to determine the most appropriate ages of initiation and cessation for CRC screening and the most appropriate screening intervals for selected CRC screening tests in people at average risk for CRC. Methods. Electronic databases were searched for studies that addressed the research objectives. Meta-analyses were conducted with clinically homogenous trials. A working group reviewed the evidence to develop conclusions. Results. Thirty RCTs and 29 observational studies were included. Flexible sigmoidoscopy (FS) prevented CRC and led to the largest reduction in CRC mortality with a smaller but significant reduction in CRC mortality with the use of guaiac fecal occult blood tests (gFOBTs). There was insufficient or low quality evidence to support the use of other screening tests, including colonoscopy, as well as changing the ages of initiation and cessation for CRC screening with gFOBTs in Ontario. Either annual or biennial screening using gFOBT reduces CRC-related mortality. Conclusion. The evidentiary base supports the use of FS or FOBT (either annual or biennial) to screen patients at average risk for CRC. This work will guide the development of the provincial CRC screening program.

  12. Evolution of cervical cancer screening and prevention in United States and Canada: Implications for public health practitioners and clinicians☆,☆☆

    PubMed Central

    Saraiya, M.; Steben, M.; Watson, M.; Markowitz, L.

    2015-01-01

    Objective Declines in cervical cancer incidence and mortality in Canada and in the United States have been widely attributed to the introduction of the Papanicolaou (Pap) test. This article reviews changes in screening and introduction of HPV vaccination. Method Sentinel events in cervical cancer screening and primary prevention through HPV vaccination in the US and Canada are described. Results Despite commonalities, cervical cancer screening and prevention differ between the two countries. Canada has a combination of opportunistic and organized programs at the provincial and territorial level, while the US has opportunistic screening and vaccination systems. In the US, the HPV test along with the Pap test (co-testing) is part of national recommendations for routine cervical cancer screening for women age 30 and older. Co-testing is not being considered anywhere in Canada, but primary HPV testing is currently recommended (but not implemented) in one province in Canada. Conclusion Many prevention strategies are available for cervical cancer. Continued public health efforts should focus on increasing vaccine coverage in the target age groups and cervical cancer screening for women at appropriate intervals. Ongoing evaluation will be needed to ensure appropriate use of health resources, as vaccinated women become eligible for screening. PMID:23402963

  13. Screening for diabetes in optometry practices: acceptability to users.

    PubMed

    Howse, Jennifer H; Jones, Steve; Hungin, A Pali S

    2011-07-01

    Diabetes is a leading cause of blindness in the working age population. While optometrists have an established role in screening people with known diabetes for eye disease, their role in screening for diabetes has not been evaluated. For diabetes screening in optometry practices to be successful it must be acceptable to both optometrists and to the public. The purpose of this study was to determine acceptability to people attending optometry practices of using random capillary blood glucose (rCBG) tests to detect raised blood glucose levels in optometry practices. A screening service offering people with risk factors or symptoms of diabetes rCBG tests was piloted in five high street opticians' practices in North East England. One thousand and two people used the screening service during a 20 week period. Each was given a questionnaire to complete and return following a rCBG test. Nine hundred and thirty-nine questionnaires were returned (return rate 93.7%). The mean age of participants was 54.5 years, 63.3% were female and 75.0% had not been screened for diabetes previously. 99.1% agreed or strongly agreed that the location was convenient for them and 98.0% would recommend others to use the screening service. 83.8% of the participants would not have gone elsewhere to have any tests done and 148 (16.2%) responded that they would have sought a test elsewhere; 14.2% at the GP, 0.8% at a pharmacy and 0.5% elsewhere. Only 3.2% reported that the test procedure was uncomfortable.   To those attending opticians' practices, screening using rCBG tests is acceptable in terms of convenience and test comfort, and they would recommend the test to others. Screening in optometry practices provides an opportunity to identify people at risk of diabetes in a hitherto unutilised setting. Ophthalmic & Physiological Optics © 2011 The College of Optometrists.

  14. A Screening Test for Wilson's Disease and its Application to Psychiatric Patients

    PubMed Central

    Cox, Diane Wilson

    1967-01-01

    Varied modes of onset make the early diagnosis of Wilson's disease difficult. A deficiency of serum ceruloplasmin, usually characteristic of the disease, was used as the basis for a screening test. Simple test materials and provision for handling about 50 plasma samples simultaneously made this test feasible for large-scale screening. The screening test was applied to 336 persons hospitalized for psychiatric disorders, to detect patients with Wilson's disease before the classical symptoms appeared. Two patients with ceruloplasmin levels below the normal limits were detected but did not have Wilson's disease. Further application of the screening test to relatives of patients known to have Wilson's disease and to individuals with any symptoms of the disease (hepatic disease, extrapyramidal dysfunction, psychiatric disorders, behaviour problems in children) would aid in early diagnosis and more effective treatment. ImagesFig. 1 PMID:6017170

  15. Interventions to increase recommendation and delivery of screening for breast, cervical, and colorectal cancers by healthcare providers systematic reviews of provider assessment and feedback and provider incentives.

    PubMed

    Sabatino, Susan A; Habarta, Nancy; Baron, Roy C; Coates, Ralph J; Rimer, Barbara K; Kerner, Jon; Coughlin, Steven S; Kalra, Geetika P; Chattopadhyay, Sajal

    2008-07-01

    Most major medical organizations recommend routine screening for breast, cervical, and colorectal cancers. Screening can lead to early detection of these cancers, resulting in reduced mortality. Yet not all people who should be screened are screened, either regularly or, in some cases, ever. This report presents results of systematic reviews of effectiveness, applicability, economic efficiency, barriers to implementation, and other harms or benefits of two provider-directed intervention approaches to increase screening for breast, cervical, and colorectal cancers. These approaches, provider assessment and feedback, and provider incentives encourage providers to deliver screening services at appropriate intervals. Evidence in these reviews indicates that provider assessment and feedback interventions can effectively increase screening by mammography, Pap test, and fecal occult blood test. Health plans, healthcare systems, and cancer control coalitions should consider such evidence-based findings when implementing interventions to increase screening use. Evidence was insufficient to determine the effectiveness of provider incentives in increasing use of any of these tests. Specific areas for further research are suggested in this report, including the need for additional research to determine whether provider incentives are effective in increasing use of any of these screening tests, and whether assessment and feedback interventions are effective in increasing other tests for colorectal cancer (i.e., flexible sigmoidoscopy, colonoscopy, or double-contrast barium enema).

  16. Contributions and Limitations of National Cervical Cancer Screening Program in Korea: A Retrospective Observational Study.

    PubMed

    Lee, Jung Hyun; Kim, Hyeongsu; Choi, Heejung; Jeong, Hyoseon; Ko, Young; Shim, Seung-Hyuk; Lee, Eunjoo; Chae, Su Hyun

    2018-03-01

    The purpose of this study was to evaluate the contributions and limitations of the cervical cancer screening test with accuracy in Korea. This was a retrospective observational study. The study population consisted of all participants who underwent cervical cancer screening test from 2009 to 2014. The data were obtained from National Health Information Database (NHID) which represents medical use records of most Koreans. As the indices for contributions and limitations of the screening test, crude detection rate, incidence rate of interval cancer, sensitivity, specificity, and positive predictive value were used. The crude detection rate of screening test per 100,000 participants increased from 100.7 in 2009 to 102.1 in 2014. The incidence rate of interval cancer per 100,000 negatives decreased from 13.0 in 2009 to 10.2 in 2014. The sensitivities of screening test were 88.7% in 2009 and 91.2% in 2014, and the specificities were 98.5% in 2009 and 97.7% in 2014. The positive predictive value of screening decreased from 6.2% in 2009 to 4.3% in 2014. The Korean national cervical cancer screening program has improved in accuracy and has contributed to detection of early stage of cervical cancer over the years. Along with efforts to promote participation in cancer screening programs, quality control over the screening program should be enhanced. Copyright © 2018. Published by Elsevier B.V.

  17. The clinical utility of HPV DNA testing in cervical cancer screening strategies.

    PubMed

    Bhatla, Neerja; Moda, Nidhi

    2009-09-01

    Cervical cancer continues to be the commonest cause of death among women in developing countries, largely due to the failure to the inability to sustain effective cytology-based screening programs. While this burden may come down following implementation of the human papillomavirus (HPV) vaccine, screening will still be required. HPV DNA testing is a promising new technology for cervical cancer prevention and is the most reproducible of all cervical cancer screening tests. Presently, the two assays most widely used for the detection of genital types are the polymerase chain reaction (PCR) and Hybrid Capture 2 assays (hc2). Rapid, affordable tests are expected to be available soon. HPV DNA testing can be used in a variety of clinical scenarios that include primary screening in women older than 30 yr; as an adjunctive test to cytology; in the triage of women with an equivocal cytologic report, e.g., ASC-US; or for follow-up post-treatment for cervical intraepithelial neoplasia (CIN). HPV DNA testing can also be performed on self-collected samples, which allows screening in remote areas and also in women who refuse gynecologic examination.

  18. 40 CFR 1066.430 - Performing emission tests.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 34 2012-07-01 2012-07-01 false Performing emission tests. 1066.430... CONTROLS VEHICLE-TESTING PROCEDURES Vehicle Preparation and Running a Test § 1066.430 Performing emission tests. The overall test consists of prescribed sequences of fueling, parking, and driving at specified...

  19. 40 CFR 1066.430 - Performing emission tests.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 34 2013-07-01 2013-07-01 false Performing emission tests. 1066.430... CONTROLS VEHICLE-TESTING PROCEDURES Vehicle Preparation and Running a Test § 1066.430 Performing emission tests. The overall test consists of prescribed sequences of fueling, parking, and driving at specified...

  20. XENOENDOCRINE DISRUPTERS-TIERED SCREENING AND TESTING: FILLING KEY DATA GAPS

    EPA Science Inventory

    ABSTRACT
    The US Environmental Protection Agency (EPA) is developing a screening and testing program for endocrine disrupting chemicals (EDCs). High priority chemicals would be evaluated in the Tier 1 Screening (T1S) battery. Chemicals positive in T1S would then be tested...

  1. A fast microchannel plate-scintillator detector for velocity map imaging and imaging mass spectrometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Winter, B.; King, S. J.; Vallance, C., E-mail: claire.vallance@chem.ox.ac.uk

    2014-02-15

    The time resolution achievable using standard position-sensitive ion detectors, consisting of a chevron pair of microchannel plates coupled to a phosphor screen, is primarily limited by the emission lifetime of the phosphor, around 70 ns for the most commonly used P47 phosphor. We demonstrate that poly-para-phenylene laser dyes may be employed extremely effectively as scintillators, exhibiting higher brightness and much shorter decay lifetimes than P47. We provide an extensive characterisation of the properties of such scintillators, with a particular emphasis on applications in velocity-map imaging and microscope-mode imaging mass spectrometry. The most promising of the new scintillators exhibits an electron-to-photonmore » conversion efficiency double that of P47, with an emission lifetime an order of magnitude shorter. The new scintillator screens are vacuum stable and show no signs of signal degradation even over longer periods of operation.« less

  2. First imagery generated by near-field real-time aperture synthesis passive millimetre wave imagers at 94 GHz and 183 GHz

    NASA Astrophysics Data System (ADS)

    Salmon, Neil A.; Mason, Ian; Wilkinson, Peter; Taylor, Chris; Scicluna, Peter

    2010-10-01

    The first passive millimetre wave (PMMW) imagery is presented from two proof-of-concept aperture synthesis demonstrators, developed to investigate the use of aperture synthesis for personnel security screening and all weather flying at 94 GHz, and satellite based earth observation at 183 GHz [1]. Emission from point noise sources and discharge tubes are used to examine the coherence on system baselines and to measure the point spread functions, making comparisons with theory. Image quality is examined using near field aperture synthesis and G-matrix calibration imaging algorithms. The radiometric sensitivity is measured using the emission from absorbers at elevated temperatures acting as extended sources and compared with theory. Capabilities of the latest Field Programmable Gate Arrays (FPGA) technologies for aperture synthesis PMMW imaging in all-weather and security screening applications are examined.

  3. Optical properties of flexible fluorescent films prepared by screen printing technology

    NASA Astrophysics Data System (ADS)

    Chen, Yan; Ke, Taiyan; Chen, Shuijin; He, Xin; Zhang, Mei; Li, Dong; Deng, Jinfeng; Zeng, Qingguang

    2018-05-01

    In this work, we prepared a fluorescent film comprised phosphors and silicone on flexible polyethylene terephthalate (PET) substrate using a screen printing technology. The effects of mesh number and weight ratio of phosphors to silicone on the optical properties of the flexible films were investigated. The results indicate that the emission intensity of the film increase as the mesh decreased from 400 to 200, but the film surface gradually becomes uneven. The fluorescent film with high emission intensity and smooth surface can be obtained when the weight ratio of phosphor to gel is 2:1, and mesh number is 300. The luminous efficiency of the fabricated LEDs combined the fluorescent films with 460 nm Ga(In)N chip module can reach 75 lm/W. The investigation indicates that the approach can be applied in the remote fluorescent film conversion and decreases the requirements of the particle size and the dispersion state of fluorescent materials.

  4. X-ray emission from high temperature plasmas

    NASA Technical Reports Server (NTRS)

    Harries, W. L.

    1974-01-01

    X-rays from a 25-hJ plasma focus apparatus were observed with pinhole cameras. The cameras consist of 0.4 mm diameter pinholes in 2 cm thick lead housing enclosing an X-ray intensifying screen at the image plane. Pictures recorded through thin aluminum foils or plastic sheets for X-ray energies sub gamma smaller than 15 keV show distributed X-ray emissions from the focussed plasma and from the anode surface. However, when thick absorbers are used, radial filamentary structure in the X-ray emission from the anode surface is revealed. Occasionally larger structures are observed in addition to the filaments. Possible mechanisms for the filamentary structure are discussed.

  5. Evaluation of a standard test method for screening fuels in soils

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sorini, S.S.; Schabron, J.F.

    1996-12-31

    A new screening method for fuel contamination in soils was recently developed as American Society for Testing and Materials (ASTM) Method D-5831-95, Standard Test Method for Screening Fuels in Soils. This method uses low-toxicity chemicals and can be sued to screen organic- rich soils, as well as being fast, easy, and inexpensive to perform. Fuels containing aromatic compounds, such as diesel fuel and gasoline, as well as other aromatic-containing hydrocarbon materials, such as motor oil, crude oil, and cola oil, can be determined. The screening method for fuels in soils was evaluated by conducting a Collaborative study on the method.more » In the Collaborative study, a sand and an organic soil spiked with various concentrations of diesel fuel were tested. Data from the Collaborative study were used to determine the reproducibility (between participants) and repeatability (within participants) precision of the method for screening the test materials. The Collaborative study data also provide information on the performance of portable field equipment (patent pending) versus laboratory equipment for performing the screening method and a comparison of diesel concentration values determined using the screening method versus a laboratory method.« less

  6. Evaluation of bus emissions generated near bus stops

    NASA Astrophysics Data System (ADS)

    Yu, Qian; Li, Tiezhu

    2014-03-01

    The purpose of this research is to demonstrate a methodology for quantification of bus emissions generated near bus stops based on the real-world on-road emissions data collected by the Portable Emission Measurement System (PEMS). Data collection was carried out on an urban diesel bus throughout a bus line under normal operation condition on four work days. Stop influence zone is defined as the area in which the normal bus driving is interrupted by bus stops. The second-by-second data were screened out within the stop influence zone. And the bus running state near a stop was classified into three driving modes, deceleration, idling, and acceleration. Then emission characteristics were analyzed for each mode. Under the idling condition, the emission rates (g s-1) were not constant all the time. The NOX emission rate decreased in the first 4-6 s while the corresponding emission rates of CO2, CO, NOX, and HC increased in the last 4 s of idling. Besides, the influence of bus stop characteristics on emissions was investigated using statistical methods. Platform type, length and location of bus stops showed significant effects on the length of the stop influence zone. However, there were no significant effects on distance-based emission factors.

  7. Prevalence of auditory changes in newborns in a teaching hospital

    PubMed Central

    Guimarães, Valeriana de Castro; Barbosa, Maria Alves

    2012-01-01

    Summary Introduction: The precocious diagnosis and the intervention in the deafness are of basic importance in the infantile development. The loss auditory and more prevalent than other joined riots to the birth. Objective: Esteem the prevalence of auditory alterations in just-born in a hospital school. Method: Prospective transversal study that evaluated 226 just-been born, been born in a public hospital, between May of 2008 the May of 2009. Results: Of the 226 screened, 46 (20.4%) had presented absence of emissions, having been directed for the second emission. Of the 26 (56.5%) children who had appeared in the retest, 8 (30.8%) had remained with absence and had been directed to the Otolaryngologist. Five (55.5%) had appeared and had been examined by the doctor. Of these, 3 (75.0%) had presented normal otoscopy, being directed for evaluation of the Evoked Potential Auditory of Brainstem (PEATE). Of the total of studied children, 198 (87.6%) had had presence of emissions in one of the tests and, 2 (0.9%) with deafness diagnosis. Conclusion: The prevalence of auditory alterations in the studied population was of 0,9%. The study it offers given excellent epidemiologists and it presents the first report on the subject, supplying resulted preliminary future implantation and development of a program of neonatal auditory selection. PMID:25991933

  8. Quantification of emissions from knapsack sprayers: 'the weight method

    NASA Astrophysics Data System (ADS)

    Garcia-Santos, Glenda; Binder, Claudia R.

    2010-05-01

    Misuse of pesticides kill or seriously sicken thousands of people every year and poison the natural environment. Investigations of occupational and environmental risk have received considerable interest over the last decades. And yet, lack of staff and analytical equipments as well the costs of chemical analyses make difficult, if not impossible, the control of the pesticide contamination and residues in humans, air, water, and soils in developing countries. To assess emissions of pesticides (transport and deposition) during spray application and the risk for the human health and the environment, tracers can be useful tools. Uranine was used to quantify drift airborne and later deposition on the neighbouring field and clothes of the applicator after spraying with a knapsack sprayer in one of the biggest areas of potato production in Colombia. Keeping the same setup the amount of wet drift was measured by difference in the weight of high absorbent papers used to collect the tracer. Surprisingly this weight method (Weight-HAP) was able to explain 71% of the drift variance measured with the tracer. Therefore the weight method is presented as a suitable rapid low cost screening tool, complementary to toxicological tests, to assess air pollution, occupational and environmental exposure generated by the emissions from knapsack sprayers during pesticide application. This technique might be important in places were there is lack of analytical instruments.

  9. 76 FR 49473 - Petition to Maximize Practical Utility of List 1 Chemicals Screened Through EPA's Endocrine...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-10

    ... Utility of List 1 Chemicals Screened Through EPA's Endocrine Disruptor Screening Program; Notice of... to the test orders issued under the Endocrine Disruptor Screening Program. DATES: Comments must be... testing of chemical substances for potential endocrine effects. Potentially affected entities, identified...

  10. Cervical Cancer Screening Among Adult Women in China, 2010

    PubMed Central

    Wang, Baohua; He, Minfu; Chao, Ann; Engelgau, Michael M.; Saraiya, Mona; Wang, Limin

    2015-01-01

    Introduction. Cervical cancer is one of the most commonly diagnosed cancers among women in China. The World Health Organization (WHO) recommends routine screening for cervical cancer, and the WHO Global Monitoring Framework suggests that every nation monitors cervical cancer screening. However, little information is available on cervical cancer screening behavior among women in China. Methods. We used data from the 2010 China Chronic Disease and Risk Factor Surveillance System that included 51,989 women aged 18 years and older. We report the proportion of women who reported ever having had a Papanicolaou (Pap) test, stratified by sociodemographic characteristics and geographic region. Multivariable logistic regression modeling was performed to adjust for potential confounders. Results. Overall, 21% of 51,989 women reported having ever had a Pap test. The highest proportion was reported among women aged 30–39 years (30.1%, 95% confidence interval, 26.8%–33.4%). In all geographic regions, women in rural areas were consistently less likely than women in urban areas to report having had a Pap test. Among women who reported ever having a Pap test, 82% reported having the most recent test in the past 3 years. Factors associated with reporting ever having a test were being aged 30–49 years, higher education, being married, and having urban health insurance. Conclusion. Our results indicate that screening programs need to be strengthened along with a more intense focus on specific demographic groups. National cervical cancer screening guidelines and comprehensive implementation strategies are needed to make screening services available and accessible to all women. Implications for Practice: This study is the largest nationwide and population-based assessment of self-reported history of Pap test for cervical cancer screening in China. This article describes cervical cancer screening behavior among women and examines key demographic and geographic factors. Only one fifth of Chinese women reported having ever had a Pap test for cervical cancer screening. The results highlight the urgent need to develop national cervical cancer screening guidelines and strategies that make screening services widely available, accessible, and acceptable to all women, especially to those who reside in rural areas and those with no health insurance. PMID:25956407

  11. A hybrid method for provincial scale energy-related carbon emission allocation in China.

    PubMed

    Bai, Hongtao; Zhang, Yingxuan; Wang, Huizhi; Huang, Yanying; Xu, He

    2014-01-01

    Achievement of carbon emission reduction targets proposed by national governments relies on provincial/state allocations. In this study, a hybrid method for provincial energy-related carbon emissions allocation in China was developed to provide a good balance between production- and consumption-based approaches. In this method, provincial energy-related carbon emissions are decomposed into direct emissions of local activities other than thermal power generation and indirect emissions as a result of electricity consumption. Based on the carbon reduction efficiency principle, the responsibility for embodied emissions of provincial product transactions is assigned entirely to the production area. The responsibility for carbon generation during the production of thermal power is borne by the electricity consumption area, which ensures that different regions with resource endowments have rational development space. Empirical studies were conducted to examine the hybrid method and three indices, per capita GDP, resource endowment index and the proportion of energy-intensive industries, were screened to preliminarily interpret the differences among China's regional carbon emissions. Uncertainty analysis and a discussion of this method are also provided herein.

  12. Universal Versus Targeted Screening for Lynch Syndrome: Comparing Ascertainment and Costs Based on Clinical Experience.

    PubMed

    Erten, Mujde Z; Fernandez, Luca P; Ng, Hank K; McKinnon, Wendy C; Heald, Brandie; Koliba, Christopher J; Greenblatt, Marc S

    2016-10-01

    Strategies to screen colorectal cancers (CRCs) for Lynch syndrome are evolving rapidly; the optimal strategy remains uncertain. We compared targeted versus universal screening of CRCs for Lynch syndrome. In 2010-2011, we employed targeted screening (age < 60 and/or Bethesda criteria). From 2012 to 2014, we screened all CRCs. Immunohistochemistry for the four mismatch repair proteins was done in all cases, followed by other diagnostic studies as indicated. We modeled the diagnostic costs of detecting Lynch syndrome and estimated the 5-year costs of preventing CRC by colonoscopy screening, using a system dynamics model. Using targeted screening, 51/175 (29 %) cancers fit criteria and were tested by immunohistochemistry; 15/51 (29 %, or 8.6 % of all CRCs) showed suspicious loss of ≥1 mismatch repair protein. Germline mismatch repair gene mutations were found in 4/4 cases sequenced (11 suspected cases did not have germline testing). Using universal screening, 17/292 (5.8 %) screened cancers had abnormal immunohistochemistry suspicious for Lynch syndrome. Germline mismatch repair mutations were found in only 3/10 cases sequenced (7 suspected cases did not have germline testing). The mean cost to identify Lynch syndrome probands was ~$23,333/case for targeted screening and ~$175,916/case for universal screening at our institution. Estimated costs to identify and screen probands and relatives were: targeted, $9798/case and universal, $38,452/case. In real-world Lynch syndrome management, incomplete clinical follow-up was the major barrier to do genetic testing. Targeted screening costs 2- to 7.5-fold less than universal and rarely misses Lynch syndrome cases. Future changes in testing costs will likely change the optimal algorithm.

  13. 40 CFR 51.358 - Test equipment.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... vehicle description, including license plate number, vehicle identification number, and odometer reading... emissions test on subject vehicles. (a) Performance features of computerized emission test systems. The...) Emission test equipment shall be capable of testing all subject vehicles and shall be updated from time to...

  14. 40 CFR 51.358 - Test equipment.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... vehicle description, including license plate number, vehicle identification number, and odometer reading... emissions test on subject vehicles. (a) Performance features of computerized emission test systems. The...) Emission test equipment shall be capable of testing all subject vehicles and shall be updated from time to...

  15. 40 CFR 51.358 - Test equipment.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... vehicle description, including license plate number, vehicle identification number, and odometer reading... emissions test on subject vehicles. (a) Performance features of computerized emission test systems. The...) Emission test equipment shall be capable of testing all subject vehicles and shall be updated from time to...

  16. Study designs for determining and comparing sensitivities of disease screening tests.

    PubMed

    Prorok, Philip C; Kramer, Barnett S; Miller, Anthony B

    2015-12-01

    To investigate the capability of various study designs to determine the sensitivity of a disease screening test. Quantities that can be calculated from these designs were derived and examined for their relationship to true sensitivity (the ability to detect unrecognized disease that would surface clinically in the absence of screening) and overdiagnosis. To examine the sensitivity of one test, the single cohort design, in which all participants receive the test, is particularly weak, providing only an upper bound on the true sensitivity, and yields no information about overdiagnosis. A randomized design, with one control arm and participants tested in the other, that includes sufficient post-screening follow-up, allows calculation of bounds on, and an approximation to, true sensitivity and also determination of overdiagnosis. Without follow-up, bounds on the true sensitivity can be calculated. To compare two tests, the single cohort paired design in which all participants receive both tests is precarious. The three arm randomized design with post screening follow-up is preferred, yielding an approximation to the true sensitivity, bounds on the true sensitivity, and the extent of overdiagnosis of each test. Without post screening follow-up, bounds on the true sensitivities can be calculated. When an unscreened control arm is not possible, the two-arm randomized design is recommended. Individual test sensitivities cannot be determined, but with sufficient post-screening follow-up, an order relationship can be established, as can the difference in overdiagnosis between the two tests. © The Author(s) 2015.

  17. Which BRCA genetic testing programs are ready for implementation in health care? A systematic review of economic evaluations.

    PubMed

    D'Andrea, Elvira; Marzuillo, Carolina; De Vito, Corrado; Di Marco, Marco; Pitini, Erica; Vacchio, Maria Rosaria; Villari, Paolo

    2016-12-01

    There is considerable evidence regarding the efficacy and effectiveness of BRCA genetic testing programs, but whether they represent good use of financial resources is not clear. Therefore, we aimed to identify the main health-care programs for BRCA testing and to evaluate their cost-effectiveness. We performed a systematic review of full economic evaluations of health-care programs involving BRCA testing. Nine economic evaluations were included, and four main categories of BRCA testing programs were identified: (i) population-based genetic screening of individuals without cancer, either comprehensive or targeted based on ancestry; (ii) family history (FH)-based genetic screening, i.e., testing individuals without cancer but with FH suggestive of BRCA mutation; (iii) familial mutation (FM)-based genetic screening, i.e., testing individuals without cancer but with known familial BRCA mutation; and (iv) cancer-based genetic screening, i.e., testing individuals with BRCA-related cancers. Currently BRCA1/2 population-based screening represents good value for the money among Ashkenazi Jews only. FH-based screening is potentially very cost-effective, although further studies that include costs of identifying high-risk women are needed. There is no evidence of cost-effectiveness for BRCA screening of all newly diagnosed cases of breast/ovarian cancers followed by cascade testing of relatives, but programs that include tools for identifying affected women at higher risk for inherited forms are promising. Cost-effectiveness is highly sensitive to the cost of BRCA1/2 testing.Genet Med 18 12, 1171-1180.

  18. Estimating Full IM240 Emissions from Partial Test Results: Evidence from Arizona.

    PubMed

    Ando, Amy W; Harrington, Winston; McConnell, Virginia

    1999-10-01

    The expense and inconvenience of enhanced-vehicle-emissions testing using the full 240-second dynamometer test has led states to search for ways to shorten the test process. In fact, all states that currently use the IM240 allow some type of fast-pass, usually as early in the test as second 31, and Arizona has allowed vehicles to fast-fail after second 93. While these shorter tests save states millions of dollars in inspection lanes and driver costs, there is a loss of information since test results are no longer comparable across vehicles. This paper presents a methodology for estimating full 240-second results from partial-test results for three pollutants: HC, CO, and NO x . If states can convert all tests to consistent IM240 readings, they will be able to better characterize fleet emissions and to evaluate the impact of inspection and maintenance and other programs on emissions over time. Using a random sample of vehicles in Arizona which received full 240-second tests, we use regression analysis to estimate the relationship between emissions at second 240 and emissions at earlier seconds in the test. We examine the influence of other variables such as age, model-year group, and the pollution level itself on this relationship. We also use the estimated coefficients in several applications. First, we try to shed light on the frequent assertion that the results of the dynamometer test provide guidance for vehicle repair of failing vehicles. Using a probit analysis, we find that the probability that a failing vehicle will pass the test on the first retest is greater the longer the test has progressed. Second, we test the accuracy of our estimates for forecasting fleet emissions from partial-test emissions results in Arizona. We find forecasted fleet average emissions to be very close to the actual fleet averages for light-duty vehicles, but not quite as good for trucks, particularly when NO x emissions are forecast.

  19. Optimization of PSA screening policies: a comparison of the patient and societal perspectives.

    PubMed

    Zhang, Jingyu; Denton, Brian T; Balasubramanian, Hari; Shah, Nilay D; Inman, Brant A

    2012-01-01

    To estimate the benefit of PSA-based screening for prostate cancer from the patient and societal perspectives. A partially observable Markov decision process model was used to optimize PSA screening decisions. Age-specific prostate cancer incidence rates and the mortality rates from prostate cancer and competing causes were considered. The model trades off the potential benefit of early detection with the cost of screening and loss of patient quality of life due to screening and treatment. PSA testing and biopsy decisions are made based on the patient's probability of having prostate cancer. Probabilities are inferred based on the patient's complete PSA history using Bayesian updating. The results of all PSA tests and biopsies done in Olmsted County, Minnesota, from 1993 to 2005 (11,872 men and 50,589 PSA test results). Patients' perspective: to maximize expected quality-adjusted life years (QALYs); societal perspective: to maximize the expected monetary value based on societal willingness to pay for QALYs and the cost of PSA testing, prostate biopsies, and treatment. From the patient perspective, the optimal policy recommends stopping PSA testing and biopsy at age 76. From the societal perspective, the stopping age is 71. The expected incremental benefit of optimal screening over the traditional guideline of annual PSA screening with threshold 4.0 ng/mL for biopsy is estimated to be 0.165 QALYs per person from the patient perspective and 0.161 QALYs per person from the societal perspective. PSA screening based on traditional guidelines is found to be worse than no screening at all. PSA testing done with traditional guidelines underperforms and therefore underestimates the potential benefit of screening. Optimal screening guidelines differ significantly depending on the perspective of the decision maker.

  20. 40 CFR 86.1835-01 - Confirmatory certification testing.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... emission standard; (ii) The test exhibits high emission levels determined by exceeding a percentage of the...) Testing by the Administrator. (1) The Administrator may require that any one or more of the test vehicles... conducting emissions tests. The Administrator may specify that such testing be conducted at the manufacturer...

  1. Development and validation of the assessment of health literacy in breast and cervical cancer screening.

    PubMed

    Han, Hae-Ra; Huh, Boyun; Kim, Miyong T; Kim, Jiyun; Nguyen, Tam

    2014-01-01

    For many people limited health literacy is a major barrier to effective preventive health behavior such as cancer screening, yet a comprehensive health literacy measure that is specific to breast and cervical cancer screening is not readily available. The purpose of this article is to describe the development and testing of a new instrument to measure health literacy in the context of breast and cervical cancer screening, the Assessment of Health Literacy in Cancer Screening (AHL-C). The AHL-C is based on Baker's conceptualization of health literacy and modeled from the two most popular health literacy tests, the Rapid Estimate of Adult Literacy in Medicine and the Test of Functional Health Literacy in Adults. The AHL-C consists of four subscales; print literacy, numeracy, comprehension, and familiarity. We used baseline data from 560 Korean American immigrant women who participated in a community-based randomized trial designed to test the effect of a health literacy-focused intervention to promote breast and cervical cancer screening. Rigorous psychometric testing supports that the AHL-C is reliable, valid, and significantly correlated with theoretically selected variables. Future research is needed to test the utility of the AHL-C in predicting cancer screening outcomes.

  2. Changes in screening behaviors and attitudes toward screening from pre-test genetic counseling to post-disclosure in Lynch syndrome families

    PubMed Central

    Burton-Chase, Allison M.; Hovick, Shelly R.; Peterson, Susan K.; Marani, Salma K.; Vernon, Sally W.; Amos, Christopher I.; Frazier, Marsha L.; Lynch, Patrick M.; Gritz, Ellen R.

    2013-01-01

    Purpose This study examined colonoscopy adherence and attitudes towards colorectal cancer (CRC) screening in individuals who underwent Lynch syndrome genetic counseling and testing. Methods We evaluated changes in colonoscopy adherence and CRC screening attitudes in 78 cancer-unaffected relatives of Lynch syndrome mutation carriers before pre-test genetic counseling (baseline) and at 6 and 12 months post-disclosure of test results (52 mutation-negative, 26 mutation-positive). Results While both groups were similar at baseline, at 12 months post-disclosure, a greater number of mutation-positive individuals had had a colonoscopy compared with mutation-negative individuals. From baseline to 12 months post-disclosure, the mutation-positive group demonstrated an increase in mean scores on measures of colonoscopy commitment, self-efficacy, and perceived benefits of CRC screening, and a decrease in mean scores for perceived barriers to CRC screening. Mean scores on colonoscopy commitment decreased from baseline to 6 months in the mutation-negative group. Conclusion Adherence to risk-appropriate guidelines for CRC surveillance improved after genetic counseling and testing for Lynch syndrome. Mutation-positive individuals reported increasingly positive attitudes toward CRC screening after receiving genetic test results, potentially reinforcing longer term colonoscopy adherence. PMID:23414081

  3. Comparison of cytology, HPV DNA testing and HPV 16/18 genotyping alone or combined targeting to the more balanced methodology for cervical cancer screening.

    PubMed

    Chatzistamatiou, Kimon; Moysiadis, Theodoros; Moschaki, Viktoria; Panteleris, Nikolaos; Agorastos, Theodoros

    2016-07-01

    The objective of the present study was to identify the most effective cervical cancer screening algorithm incorporating different combinations of cytology, HPV testing and genotyping. Women 25-55years old recruited for the "HERMES" (HEllenic Real life Multicentric cErvical Screening) study were screened in terms of cytology and high-risk (hr) HPV testing with HPV 16/18 genotyping. Women positive for cytology or/and hrHPV were referred for colposcopy, biopsy and treatment. Ten screening algorithms based on different combinations of cytology, HPV testing and HPV 16/18 genotyping were investigated in terms of diagnostic accuracy. Three clusters of algorithms were formed according to the balance between effectiveness and harm caused by screening. The cluster showing the best balance included two algorithms based on co-testing and two based on HPV primary screening with HPV 16/18 genotyping. Among these, hrHPV testing with HPV 16/18 genotyping and reflex cytology (atypical squamous cells of undetermined significance - ASCUS threshold) presented the optimal combination of sensitivity (82.9%) and specificity relative to cytology alone (0.99) with 1.26 false positive rate relative to cytology alone. HPV testing with HPV 16/18 genotyping, referring HPV 16/18 positive women directly to colposcopy, and hrHPV (non 16/18) positive women to reflex cytology (ASCUS threshold), as a triage method to colposcopy, reflects the best equilibrium between screening effectiveness and harm. Algorithms, based on cytology as initial screening method, on co-testing or HPV primary without genotyping, and on HPV primary with genotyping but without cytology triage, are not supported according to the present analysis. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. Point-of-care urine tests for smoking status and isoniazid treatment monitoring in adult patients.

    PubMed

    Nicolau, Ioana; Tian, Lulu; Menzies, Dick; Ostiguy, Gaston; Pai, Madhukar

    2012-01-01

    Poor adherence to isoniazid (INH) preventive therapy (IPT) is an impediment to effective control of latent tuberculosis (TB) infection. TB patients who smoke are at higher risk of latent TB infection, active disease, and TB mortality, and may have lower adherence to their TB medications. The objective of our study was to validate IsoScreen and SmokeScreen (GFC Diagnostics, UK), two point-of-care tests for monitoring INH intake and determining smoking status. The tests could be used together in the same individual to help identify patients with a high-risk profile and provide a tailored treatment plan that includes medication management, adherence interventions, and smoking cessation programs. 200 adult outpatients attending the TB and/or the smoking cessation clinic were recruited at the Montreal Chest Institute. Sensitivity and specificity were measured for each test against the corresponding composite reference standard. Test reliability was measured using kappa statistic for intra-rater and inter-rater agreement. Univariate and multivariate logistic regression models were used to explore possible covariates that might be related to false-positive and false-negative test results. IsoScreen had a sensitivity of 93.2% (95% confidence interval [CI] 80.3, 98.2) and specificity of 98.7% (94.8, 99.8). IsoScreen had intra-rater agreement (kappa) of 0.75 (0.48, 0.94) and inter-rater agreement of 0.61 (0.27, 0.90). SmokeScreen had a sensitivity of 69.2% (56.4, 79.8), specificity of 81.6% (73.0, 88.0), intra-rater agreement of 0.77 (0.56, 0.94), and inter-rater agreement of 0.66 (0.42, 0.88). False-positive SmokeScreen tests were strongly associated with INH treatment. IsoScreen had high validity and reliability, whereas SmokeScreen had modest validity and reliability. SmokeScreen tests did not perform well in a population receiving INH due to the association between INH treatment and false-positive SmokeScreen test results. Development of the next generation SmokeScreen assay should account for this potential interference.

  5. Point-of-Care Urine Tests for Smoking Status and Isoniazid Treatment Monitoring in Adult Patients

    PubMed Central

    Nicolau, Ioana; Tian, Lulu; Menzies, Dick; Ostiguy, Gaston; Pai, Madhukar

    2012-01-01

    Background Poor adherence to isoniazid (INH) preventive therapy (IPT) is an impediment to effective control of latent tuberculosis (TB) infection. TB patients who smoke are at higher risk of latent TB infection, active disease, and TB mortality, and may have lower adherence to their TB medications. The objective of our study was to validate IsoScreen and SmokeScreen (GFC Diagnostics, UK), two point-of-care tests for monitoring INH intake and determining smoking status. The tests could be used together in the same individual to help identify patients with a high-risk profile and provide a tailored treatment plan that includes medication management, adherence interventions, and smoking cessation programs. Methodology/Principal Findings 200 adult outpatients attending the TB and/or the smoking cessation clinic were recruited at the Montreal Chest Institute. Sensitivity and specificity were measured for each test against the corresponding composite reference standard. Test reliability was measured using kappa statistic for intra-rater and inter-rater agreement. Univariate and multivariate logistic regression models were used to explore possible covariates that might be related to false-positive and false-negative test results. IsoScreen had a sensitivity of 93.2% (95% confidence interval [CI] 80.3, 98.2) and specificity of 98.7% (94.8, 99.8). IsoScreen had intra-rater agreement (kappa) of 0.75 (0.48, 0.94) and inter-rater agreement of 0.61 (0.27, 0.90). SmokeScreen had a sensitivity of 69.2% (56.4, 79.8), specificity of 81.6% (73.0, 88.0), intra-rater agreement of 0.77 (0.56, 0.94), and inter-rater agreement of 0.66 (0.42, 0.88). False-positive SmokeScreen tests were strongly associated with INH treatment. Conclusions IsoScreen had high validity and reliability, whereas SmokeScreen had modest validity and reliability. SmokeScreen tests did not perform well in a population receiving INH due to the association between INH treatment and false-positive SmokeScreen test results. Development of the next generation SmokeScreen assay should account for this potential interference. PMID:23029310

  6. 77 FR 4544 - CPSC Symposium on Phthalates Screening and Testing Methods

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-30

    ... Screening and Testing Methods AGENCY: Consumer Product Safety Commission. ACTION: Notice. SUMMARY: The... symposium on phthalates screening and testing methods. The symposium will be held at the CPSC's National... submit comments, identified by Docket No. CPSC-2012-0008, by any of the following methods: Electronic...

  7. XENOENDOCRINE DISRUPTERS-TIERED SCREENING AND TESTING: FILLING KEY DATA GAPS

    EPA Science Inventory

    The US Environmental Protection Agency (EPA) is developing a screening and testing program for endocrine disrupting chemicals (EDCs). High priority chemicals would be evaluated in the Tier 1 Screening (T1S) battery. Chemicals positive in T1S would then be tested (Tier 2). T1S...

  8. Population Screening for Colorectal Cancer Means Getting FIT: The Past, Present, and Future of Colorectal Cancer Screening Using the Fecal Immunochemical Test for Hemoglobin (FIT)

    PubMed Central

    Fraser, Callum G.; Halloran, Stephen P.; Young, Graeme P.

    2014-01-01

    Fecal immunochemical tests for hemoglobin (FIT) are changing the manner in which colorectal cancer (CRC) is screened. Although these tests are being performed worldwide, why is this test different from its predecessors? What evidence supports its adoption? How can this evidence best be used? This review addresses these questions and provides an understanding of FIT theory and practices to expedite international efforts to implement the use of FIT in CRC screening. PMID:24672652

  9. Fecal occult blood testing beliefs and practices of U.S. primary care physicians: serious deviations from evidence-based recommendations.

    PubMed

    Nadel, Marion R; Berkowitz, Zahava; Klabunde, Carrie N; Smith, Robert A; Coughlin, Steven S; White, Mary C

    2010-08-01

    Fecal occult blood testing (FOBT) is an important option for colorectal cancer screening that should be available in order to achieve high population screening coverage. However, results from a national survey of clinical practice in 1999-2000 indicated that many primary care physicians used inadequate methods to implement FOBT screening and follow-up. To determine whether methods to screen for fecal occult blood have improved, including the use of newer more sensitive stool tests. Cross-sectional national survey of primary care physicians. Participants consisted of 1,134 primary care physicians who reported ordering or performing FOBT in the 2006-2007 National Survey of Primary Care Physicians' Recommendations and Practices for Cancer Screening. Self-reported data on details of FOBT implementation and follow-up of positive results. Most physicians report using standard guaiac tests; higher sensitivity guaiac tests and immunochemical tests were reported by only 22.0% and 8.9%, respectively. In-office testing, that is, testing of a single specimen collected during a digital rectal examination in the office, is still widely used although inappropriate for screening: 24.9% of physicians report using only in-office tests and another 52.9% report using both in-office and home tests. Recommendations improved for follow-up after a positive test: fewer physicians recommend repeating the FOBT (17.8%) or using tests other than colonoscopy for the diagnostic work-up (6.6%). Only 44.3% of physicians who use home tests have reminder systems to ensure test completion and return. Many physicians continue to use inappropriate methods to screen for fecal occult blood. Intensified efforts to inform physicians of recommended technique and promote the use of tracking systems are needed.

  10. Infrared non-destructive evaluation method and apparatus

    DOEpatents

    Baleine, Erwan; Erwan, James F; Lee, Ching-Pang; Stinelli, Stephanie

    2014-10-21

    A method of nondestructive evaluation and related system. The method includes arranging a test piece (14) having an internal passage (18) and an external surface (15) and a thermal calibrator (12) within a field of view (42) of an infrared sensor (44); generating a flow (16) of fluid characterized by a fluid temperature; exposing the test piece internal passage (18) and the thermal calibrator (12) to fluid from the flow (16); capturing infrared emission information of the test piece external surface (15) and of the thermal calibrator (12) simultaneously using the infrared sensor (44), wherein the test piece infrared emission information includes emission intensity information, and wherein the thermal calibrator infrared emission information includes a reference emission intensity associated with the fluid temperature; and normalizing the test piece emission intensity information against the reference emission intensity.

  11. Interpretation of Errors Made by Mandarin-Speaking Children on the Preschool Language Scales--5th Edition Screening Test

    ERIC Educational Resources Information Center

    Ren, Yonggang; Rattanasone, Nan Xu; Wyver, Shirley; Hinton, Amber; Demuth, Katherine

    2016-01-01

    We investigated typical errors made by Mandarin-speaking children when measured by the Preschool Language Scales-fifth edition, Screening Test (PLS-5 Screening Test). The intention was to provide preliminary data for the development of a guideline for early childhood educators and psychologists who use the test with Mandarin-speaking children.…

  12. On the response of Y 3Al 5O 12: Ce (YAG: Ce) powder scintillating screens to medical imaging X-rays

    NASA Astrophysics Data System (ADS)

    Kandarakis, I.; Cavouras, D.; Sianoudis, I.; Nikolopoulos, D.; Episkopakis, A.; Linardatos, D.; Margetis, D.; Nirgianaki, E.; Roussou, M.; Melissaropoulos, P.; Kalivas, N.; Kalatzis, I.; Kourkoutas, K.; Dimitropoulos, N.; Louizi, A.; Nomicos, C.; Panayiotakis, G.

    2005-02-01

    The aim of this study was to examine Y 3Al 5O 12:Ce (also known as YAG:Ce) powder scintillator under X-ray imaging conditions. This material shows a very fast scintillation decay time and it has never been used in X-ray medical imaging. In the present study various scintillator layers (screens) with coating thickness ranging from 13 to 166 mg/cm 2 were prepared in our laboratory by sedimentation of Y 3Al 5O 12: Ce powder. Optical emission spectra and light emission efficiency (spectrum area over X-ray exposure) of the layers were measured under X-ray excitation using X-ray tube voltages (80-120 kVp) often employed in general medical radiography and fluoroscopy. Spectral compatibility with various optical photon detectors (photodiodes, photocathodes, charge coupled devices, films) and intrinsic conversion efficiency values were determined using emission spectrum data. In addition, parameters related to X-ray detection, energy absorption efficiency and K-fluorescence characteristic emission were calculated. A theoretical model describing radiation and light transfer through scattering media was used to fit experimental data. Intrinsic conversion efficiency (η≈0.03-0.05) and light attenuation coefficients (σ≈26.5 cm/g) were derived through this fitting. Y 3Al 5O 12:Ce showed peak emission in the wavelength range 530-550 nm. The light emission efficiency was found to be maximum for the 107 mg/cm 2 layer. Due to its "green" emission spectrum, Y 3Al 5O 12:Ce showed excellent compatibility (of the order of 0.9) with the sensitivity of many currently used photodetectors. Taking into account its very fast response Y 3Al 5O 12:Ce could be considered for application in X-ray imaging especially in various digital detectors.

  13. Nanometer-scale monitoring of quantum-confined Stark effect and emission efficiency droop in multiple GaN/AlN quantum disks in nanowires

    NASA Astrophysics Data System (ADS)

    Zagonel, L. F.; Tizei, L. H. G.; Vitiello, G. Z.; Jacopin, G.; Rigutti, L.; Tchernycheva, M.; Julien, F. H.; Songmuang, R.; Ostasevicius, T.; de la Peña, F.; Ducati, C.; Midgley, P. A.; Kociak, M.

    2016-05-01

    We report on a detailed study of the intensity dependent optical properties of individual GaN/AlN quantum disks (QDisks) embedded into GaN nanowires (NW). The structural and optical properties of the QDisks were probed by high spatial resolution cathodoluminescence (CL) in a scanning transmission electron microscope (STEM). By exciting the QDisks with a nanometric electron beam at currents spanning over three orders of magnitude, strong nonlinearities (energy shifts) in the light emission are observed. In particular, we find that the amount of energy shift depends on the emission rate and on the QDisk morphology (size, position along the NW and shell thickness). For thick QDisks (>4 nm), the QDisk emission energy is observed to blueshift with the increase of the emission intensity. This is interpreted as a consequence of the increase of carriers density excited by the incident electron beam inside the QDisks, which screens the internal electric field and thus reduces the quantum confined Stark effect (QCSE) present in these QDisks. For thinner QDisks (<3 nm ), the blueshift is almost absent in agreement with the negligible QCSE at such sizes. For QDisks of intermediate sizes there exists a current threshold above which the energy shifts, marking the transition from unscreened to partially screened QCSE. From the threshold value we estimate the lifetime in the unscreened regime. These observations suggest that, counterintuitively, electrons of high energy can behave ultimately as single electron-hole pair generators. In addition, when we increase the current from 1 to 10 pA the light emission efficiency drops by more than one order of magnitude. This reduction of the emission efficiency is a manifestation of the "efficiency droop" as observed in nitride-based 2D light emitting diodes, a phenomenon tentatively attributed to the Auger effect.

  14. [Primary care screening of problems in the elderly and a proposal for a screening protocol with a multidimensional approach].

    PubMed

    Lino, Valéria Teresa Saraiva; Portela, Margareth Crisóstomo; Camacho, Luiz Antonio Bastos; Rodrigues, Nadia Cristina Pinheiro; Andrade, Monica Kramer de Noronha; O'Dwyer, Gisele

    2016-07-21

    The objectives were to examine psychometric properties of a screening test for the elderly and to propose a protocol for use in primary care. The method consisted of four stages: (1) inter-evaluator reliability for performance tests and self-assessment questions for eight functions; (2) sensitivity and specificity of questions on depression and social support; (3) meeting of experts to select instrumental activities of daily living (IADL); and (4) elaboration of the protocol. Screening lasted 16 minutes. Inter-evaluator reliability was excellent for performance tests but poor for questions. Depression and social support showed satisfactory sensitivity and specificity (0.74/0.77 and 0.77/0.96). Four IADL were selected by more than 55% of the experts. Following the results, a screening protocol was elaborated that prioritized the use of performance tests, maintaining questions on mood, social support, and IADL. The study suggests better reproducibility of performance tests when compared to questions. For mood and social support, the questions may provide a first screening stage. The proposed protocol allows rapid screening of problems.

  15. Vehicle and Fuel Emissions Testing

    EPA Pesticide Factsheets

    EPA's National Vehicle and Fuel Emissions Laboratory's primary responsibilities include: evaluating emission control technology; testing vehicles, engines and fuels; and determining compliance with federal emissions and fuel economy standards.

  16. Screening for gonorrhoea using samples collected through the English national chlamydia screening programme and risk of false positives: a national survey of local authorities.

    PubMed

    Field, Nigel; Kennedy, Iain; Folkard, Kate; Duffell, Stephen; Town, Katy; Ison, Catherine A; Hughes, Gwenda

    2014-10-16

    To investigate use of dual tests for Chlamydia trachomatis and Neisseria gonorrhoeae on samples collected through the National Chlamydia Screening Programme (NCSP) in England. During May-July 2013, we delivered an online survey to commissioners of sexual health services in the 152 upper-tier English Local Authorities (LAs) who were responsible for commissioning chlamydia screening in people aged 15-24 years. (1) The proportion of English LAs using dual tests on samples collected by the NCSP; (2) The estimated number of gonorrhoea tests and false positives from samples collected by the NCSP, calculated using national surveillance data on the number of chlamydia tests performed, assuming the gonorrhoea prevalence to range between 0.1% and 1%, and test sensitivity and specificity of 99.5%. 64% (98/152) of LAs responded to this national survey; over half (53% (52/98)) reported currently using dual tests in community settings. There was no significant difference between LAs using and not using dual tests by chlamydia positivity, chlamydia diagnosis rate or population screening coverage. Although positive gonorrhoea results were confirmed with supplementary tests in 93% (38/41) of LAs, this occurred after patients were notified about the initial positive result in 63% (26/41). Approximately 450-4500 confirmed gonorrhoea diagnoses and 2300 false-positive screens might occur through use of dual tests on NCSP samples each year. Under reasonable assumptions, the positive predictive value of the screening test is 17-67%. Over half of English LAs already commission dual tests for samples collected by the NCSP. Gonorrhoea screening has been introduced alongside chlamydia screening in many low prevalence settings without a national evidence review or change of policy. We question the public health benefit here, and suggest that robust testing algorithms and clinical management pathways, together with rigorous evaluation, be implemented wherever dual tests are deployed. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  17. 40 CFR 63.344 - Performance test requirements and test methods.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... blanket type fume suppressants are used to control chromium emissions from a hard chromium electroplating... National Emission Standards for Chromium Emissions From Hard and Decorative Chromium Electroplating and Chromium Anodizing Tanks § 63.344 Performance test requirements and test methods. (a) Performance test...

  18. 40 CFR 63.344 - Performance test requirements and test methods.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... blanket type fume suppressants are used to control chromium emissions from a hard chromium electroplating... National Emission Standards for Chromium Emissions From Hard and Decorative Chromium Electroplating and Chromium Anodizing Tanks § 63.344 Performance test requirements and test methods. (a) Performance test...

  19. 40 CFR 63.344 - Performance test requirements and test methods.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... blanket type fume suppressants are used to control chromium emissions from a hard chromium electroplating... National Emission Standards for Chromium Emissions From Hard and Decorative Chromium Electroplating and Chromium Anodizing Tanks § 63.344 Performance test requirements and test methods. (a) Performance test...

  20. 40 CFR 61.123 - Emission testing.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS National Emission Standards for Radionuclide Emissions From Elemental Phosphorus Plants § 61.123 Emission testing. (a) Each owner or operator of an elemental phosphorus...

  1. Trade-offs in Cervical Cancer Prevention: Balancing Benefits and Risks

    PubMed Central

    Stout, Natasha K.; Goldhaber-Fiebert, Jeremy D.; Ortendahl, Jesse D.; Goldie, Sue J.

    2009-01-01

    Background New screening and vaccination technologies will provide women with more options for cervical cancer prevention. Because the risk of cervical cancer diminishes with effective routine screening, women may wish to consider additional attributes, such as the likelihood of false-positive results and diagnostic procedures for mild abnormalities likely to resolve without intervention in their screening choices. Methods We used an empirically calibrated simulation model of cervical cancer in the United States to assess the benefits and potential risks associated with prevention strategies differing by primary screening test, triage test for abnormal results (cytologic testing, human papillomavirus [HPV] DNA test), and screening frequency. Outcomes included colposcopy referrals, cervical intraepithelial neoplasia (CIN) types 1 and 2 or 3, lifetime cancer risk, and quality-adjusted life expectancy. Results Across strategies, colposcopy referrals and diagnostic workups varied 3-fold, although diagnostic rates of CIN 2 or 3 were similar and 95% of positive screening test results were for mild abnormalities likely to resolve on their own. For a representative group of a thousand 20-year-old women undergoing triennial screening for 10 years, we expect 1038 colposcopy referrals (7 CIN 2 or 3 diagnoses) from combined cytologic and HPV DNA testing and fewer than 200 referrals (6–7 CIN 2 or 3 diagnoses) for strategies that use triage testing. Similarly, for a thousand 40-year-old women, combined cytologic and HPV DNA testing led to 489 referrals (9 CIN 2 or 3), whereas alternative strategies resulted in fewer than 150 referrals (7–8 CIN 2 or 3). Using cytologic testing followed by triage testing in younger women minimizes both diagnostic workups and positive HPV test results, whereas in older women diagnostic workups are minimized with HPV DNA testing followed by cytologic triage testing. Conclusions Clinically relevant information highlighting trade-offs among cervical cancer prevention strategies allows for inclusion of personal preferences into women’s decision making about screening and provides additional dimensions to the construction of clinical guidelines. PMID:18809815

  2. Eliciting population preferences for mass colorectal cancer screening organization.

    PubMed

    Nayaradou, Maximilien; Berchi, Célia; Dejardin, Olivier; Launoy, Guy

    2010-01-01

    The implementation of mass colorectal cancer (CRC) screening is a public health priority. Population participation is fundamental for the success of CRC screening as for any cancer screening program. The preferences of the population may influence their likelihood of participation. The authors sought to elicit population preferences for CRC screening test characteristics to improve the design of CRC screening campaigns. A discrete choice experiment was used. Questionnaires were compiled with a set of pairs of hypothetical CRC screening scenarios. The survey was conducted by mail from June 2006 to October 2006 on a representative sample of 2000 inhabitants, aged 50 to 74 years from the northwest of France, who were randomly selected from electoral lists. Questionnaires were sent to 2000 individuals, each of whom made 3 or 4 discrete choices between hypothetical tests that differed in 7 attributes: how screening is offered, process, sensitivity, rate of unnecessary colonoscopy, expected mortality reduction, method of screening test result transmission, and cost. Complete responses were received from 656 individuals (32.8%). The attributes that influenced population preferences included expected mortality reduction, sensitivity, cost, and process. Participants from high social classes were particularly influenced by sensitivity. The results demonstrate that the discrete choice experiment provides information on patient preferences for CRC screening: improving screening program effectiveness, for instance, by improving test sensitivity (the most valued attribute) would increase satisfaction among the general population with regard to CRC screening programs. Additional studies are required to study how patient preferences actually affect adherence to regular screening programs.

  3. Results of a 2000 Hour Wear Tof the NEXIS Ion Engine

    NASA Technical Reports Server (NTRS)

    Snyder, John Steven; Goebel, Dan M.; Polk, James E.; Schneider, Analyn C; Sengupta, Anita

    2005-01-01

    The Nuclear Electric Xenon Ion System (NEXIS) ion thruster was developed for potential outer planet robotic missions under NASA's Prometheus program. This engine was designed to operate at power levels ranging from 16 to over 20 kWe at specific impulses of 6000 to 7500 s for burn times of up to 10 years, satisfying the requirements of nuclear electric propulsion systems such as that on the proposed Prometheus 1 mission to explore the icy moons of Jupiter. State-of-the-art performance and life assessment tools were used to design the thruster. Following the successful performance validation of a Laboratory Model thruster, Development Model hardware was fabricated and subjected to vibration and wear testing. The results of a 2000-hour wear test are reported herein. Thruster performance achieved the target requirements and was steady for the duration of the test. Ion optics performance was similarly stable. Discharge loss increases of 6 eV/ion were observed in the first 500 hours of the test and were attributed to primary electron energy decreases due to cathode insert conditioning. Relatively high recycle rates were observed and were identified to be high-voltage-to-ground arcs in the back of the thruster caused by wire insulation outgassing and electron penetration through the plasma screen. Field emission of electrons between the accelerator and screen grids was observed and attributed to evolution of field emitter sites at accelerator grid aperture edges caused by ion bombardment. Preliminary modeling and analysis indicates that the NEXIS engine can meet mission performance requirements over the required lifetime. Finally, successful validation of the NEXIS design methodology, design tools, and technologies with the results of the wear test and companion performance and vibration tests presents significant applicability of the NEXIS development effort to missions of near-term as well as long-term interest for NASA.

  4. Routine bacterial screening of apheresis platelets on Day 4 using a rapid test: a 4-year single-center experience.

    PubMed

    Dunbar, Nancy M; Kreuter, Justin D; Marx-Wood, Cynthia R; Dumont, Larry J; Szczepiorkowski, Zbigniew M

    2013-10-01

    The platelet (PLT) Pan Genera Detection test (PGD) is a rapid bacterial detection system used to screen PLTs for bacterial contamination. We report a single center 46-month experience with secondary screening of apheresis PLTs by PGD testing. Existing testing records of apheresis PLTs screened by PGD from July 2008 to April 2012 were reviewed. All PLT units were initially screened by routine postcollection culture methods. Secondary screening using PGD was performed for indated PLTs on PLT storage Day 4 and for outdated PLTs on Day 8. A total of 8535 apheresis PLTs were available in inventory during the study period. Of these, 5030 (58.9%) were dispensed and transfused before PGD testing and 3505 (41.1%) underwent PGD testing on Day 4. Twenty-five units tested on Day 4 were PGD initial reactive (0.71%). All were confirmed to be false positive by repeat PGD testing in triplicate (n=20) or by confirmatory culture (n=5). An additional 364 units that were PGD nonreactive on Day 4 were approved for transfusion on Day 6 or Day 7 due to urgent clinical need. A total of 371 outdated units underwent repeat PGD testing before discard on Day 8; all were nonreactive. Secondary PGD testing of culture-screened apheresis PLTs results in low yield in a medium-sized transfusion service. Use of PGD testing on Day 4 may allow for extension of the apheresis PLT shelf life to Day 7 for hospitals that face supply constraints. © 2013 American Association of Blood Banks.

  5. Uptake of community-based, self-collected HPV testing vs. visual inspection with acetic acid for cervical cancer screening in Kampala, Uganda: preliminary results of a randomised controlled trial.

    PubMed

    Moses, Erin; Pedersen, Heather N; Mitchell, Sheona M; Sekikubo, Musa; Mwesigwa, David; Singer, Joel; Biryabarema, Christine; Byamugisha, Josaphat K; Money, Deborah M; Ogilvie, Gina S

    2015-10-01

    To compare two cervical cancer screening methods: community-based self-collection of high-risk human papillomavirus (HR-HPV) testing and visual inspection with acetic acid (VIA). Pilot randomised controlled trial of 500 women aged 30-65 in the community of Kisenyi, Uganda. Women randomised to self-collection-based HR-HPV testing provided a cervico-vaginal swab for HR-HPV, and results were provided by phone after laboratory testing. Women who tested HPV positive were referred for VIA at the local health unit. Women randomised to VIA underwent screening at the local health unit, where women who tested positive with VIA were provided cryotherapy at time of screening, as per local standard of care. Women were referred for colposcopy when indicated. Outcome measures were uptake of screening, HR-HPV prevalence, VIA result and treatment rates. In the HR-HPV arm, 248 of 250 (p < 0.01) women provided samples, while in the VIA arm, 121 of 250 (48.4%) women attended screening. Among the 73 of 248 HR-HPV-positive women, 45.2% (N = 33) attended VIA screening for follow-up, 21.2% (N = 7) of whom screened positive; five received treatment and two were missing clinical follow-up records. Of the 121 women in the VIA arm who attended screening, 13.2% (N = 16) screened positive; seven received cryotherapy, three refused treatment, five were referred to colposcopy; and one woman had suspected cervical cancer and received treatment after confirmatory testing. This pilot study demonstrated trial feasibility and willingness of the women to participate and be randomised successfully into the two arms. Self-collection-based cervical cancer screening had a higher uptake than VIA. © 2015 John Wiley & Sons Ltd.

  6. Screening men for prostate and colorectal cancer in the United States: does practice reflect the evidence?

    PubMed

    Sirovich, Brenda E; Schwartz, Lisa M; Woloshin, Steven

    2003-03-19

    The debate about the efficacy of prostate-specific antigen (PSA) screening for prostate cancer has received substantial attention in the medical literature and the media, but the extent to which men are actually screened is unknown. If practice were evidence-based, PSA screening would be less common among men than colorectal cancer screening, a preventive service of broad acceptance and proven efficacy. To compare the prevalences of PSA and colorectal cancer screening among US men. The 2001 Behavioral Risk Factor Surveillance System, an annual population-based telephone survey of US adults conducted by the Centers for Disease Control and Prevention, was used to gather data on a representative sample of men aged 40 years or older from all 50 states and the District of Columbia (n = 49 315). Proportions of men ever screened and up to date on screening for prostate cancer (with PSA testing) and colorectal cancer (with fecal occult blood testing, flexible sigmoidoscopy, or colonoscopy). Overall, men are more likely to report having ever been screened for prostate cancer than for colorectal cancer; 75% of those aged 50 years or older have had a PSA test vs 63% for any colorectal cancer test (risk ratio [RR], 1.20; 95% confidence interval [CI], 1.18-1.21). Up-to-date PSA screening is also more common than colorectal cancer screening for men of all ages. Among men aged 50 to 69 years (those for whom there is the greatest consensus in favor of screening), 54% reported an up-to-date PSA screen, while 45% reported up-to-date testing for colorectal cancer (RR, 1.19; 95% CI, 1.16-1.21). In state-level analyses of this age group, men were significantly more likely to be up to date on prostate cancer screening compared with colorectal cancer screening in 27 states, while up-to-date colorectal cancer screening was more common in only 1 state. Among men in the United States, prostate cancer screening is more common than colorectal cancer screening. Physicians should ensure that men who choose to be screened for cancer are aware of the known mortality benefit of colorectal cancer screening and the uncertain benefits of screening for prostate cancer.

  7. Nano Catalysts for Diesel Engine Emission Remediation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Narula, Chaitanya Kumar; Yang, Xiaofan; Debusk, Melanie Moses

    2012-06-01

    The objective of this project was to develop durable zeolite nanocatalysts with broader operating temperature windows to treat diesel engine emissions to enable diesel engine based equipment and vehicles to meet future regulatory requirements. A second objective was to improve hydrothermal durability of zeolite catalysts to at least 675 C. The results presented in this report show that we have successfully achieved both objectives. Since it is accepted that the first step in NO{sub x} conversion under SCR (selective catalytic reduction) conditions involves NO oxidation to NO{sub 2}, we reasoned that catalyst modification that can enhance NO oxidation at low-temperaturesmore » should facilitate NO{sub x} reduction at low temperatures. Considering that Cu-ZSM-5 is a more efficient catalyst than Fe-ZSM-5 at low-temperature, we chose to modify Cu-ZSM-5. It is important to point out that the poor low-temperature efficiency of Fe-ZSM-5 has been shown to be due to selective absorption of NH{sub 3} at low-temperatures rather than poor NO oxidation activity. In view of this, we also reasoned that an increased electron density on copper in Cu-ZSM-5 would inhibit any bonding with NH{sub 3} at low-temperatures. In addition to modified Cu-ZSM-5, we synthesized a series of new heterobimetallic zeolites, by incorporating a secondary metal cation M (Sc{sup 3+}, Fe{sup 3+}, In{sup 3+}, and La{sup 3+}) in Cu exchanged ZSM-5, zeolite-beta, and SSZ-13 zeolites under carefully controlled experimental conditions. Characterization by diffuse-reflectance ultra-violet-visible spectroscopy (UV-Vis), X-ray powder diffraction (XRD), extended X-ray absorption fine structure spectroscopy (EXAFS) and electron paramagnetic resonance spectroscopy (EPR) does not permit conclusive structural determination but supports the proposal that M{sup 3+} has been incorporated in the vicinity of Cu(II). The protocols for degreening catalysts, testing under various operating conditions, and accelerated aging conditions were provided by our collaborators at John Deere Power Systems. Among various zeolites reported here, CuFe-SSZ-13 offers the best NO{sub x} conversion activity in 150-650 C range and is hydrothermally stable when tested under accelerated aging conditions. It is important to note that Cu-SSZ-13 is now a commercial catalyst for NO{sub x} treatment on diesel passenger vehicles. Thus, our catalyst performs better than the commercial catalyst under fast SCR conditions. We initially focused on fast SCR tests to enable us to screen catalysts rapidly. Only the catalysts that exhibit high NO{sub x} conversion at low temperatures are selected for screening under varying NO{sub 2}:NO{sub x} ratio. The detailed tests of CuFe-SSZ-13 show that CuFe-SSZ-13 is more effective than commercial Cu-SSZ-13 even at NO{sub 2}:NO{sub x} ratio of 0.1. The mechanistic studies, employing stop-flow diffuse reflectance FTIR spectroscopy (DRIFTS), suggest that high concentration of NO{sup +}, generated by heterobimetallic zeolites, is probably responsible for their superior low temperature NO{sub x} activity. The results described in this report clearly show that we have successfully completed the first step in a new emission treatment catalyst which is synthesis and laboratory testing employing simulated exhaust. The next step in the catalyst development is engine testing. Efforts are in progress to obtain follow-on funding to carry out scale-up and engine testing to facilitate commercialization of this technology.« less

  8. Computerized reminders for five preventive screening tests: generation of patient-specific letters incorporating physician preferences.

    PubMed Central

    Murphy, D. J.; Gross, R.; Buchanan, J.

    2000-01-01

    Compliance with preventive screening tests is inadequate in the United States. We describe a computer based system for generating reminder letters to patients who may have missed their indicated screening tests because they do not visit a provider regularly or missed their tests despite the fact that they do visit a provider. We started with national recommendations and generated a local consensus for test indications. We then used this set of indications and our electronic record to determine test deficiencies in our pilot pool of 3073 patients. The computer generated customized reminder letters targeting several tests. Physicians chose any patients who should not receive letters. The response rate for fecal occult blood (FOB) testing was 33% compared with an 18% historical compliance rate within the same community. FOB reminders generated improved test compliance. Test execution must be considered when commencing a program of screening test reminders. PMID:11079954

  9. 40 CFR 1065.530 - Emission test sequence.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... temperature continuously to verify that it remains within the pre-test temperature range as specified in... 40 Protection of Environment 34 2013-07-01 2013-07-01 false Emission test sequence. 1065.530... CONTROLS ENGINE-TESTING PROCEDURES Performing an Emission Test Over Specified Duty Cycles § 1065.530...

  10. 40 CFR 1065.530 - Emission test sequence.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... temperature continuously to verify that it remains within the pre-test temperature range as specified in... 40 Protection of Environment 34 2012-07-01 2012-07-01 false Emission test sequence. 1065.530... CONTROLS ENGINE-TESTING PROCEDURES Performing an Emission Test Over Specified Duty Cycles § 1065.530...

  11. 40 CFR 1065.530 - Emission test sequence.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... temperature continuously to verify that it remains within the pre-test temperature range as specified in... 40 Protection of Environment 33 2014-07-01 2014-07-01 false Emission test sequence. 1065.530... CONTROLS ENGINE-TESTING PROCEDURES Performing an Emission Test Over Specified Duty Cycles § 1065.530...

  12. POHCS AND PICS SCREENING PROTOCOL

    EPA Science Inventory

    The report describes risk-driven analysis strategies and a tiered survey approach of analyses that should be useful for building data bases related to other waste combustion processes. NOTE: The need to characterize hazardous waste incinerator emissions for multiple organic compo...

  13. Screening markers for chronic atrophic gastritis in Chiapas, Mexico.

    PubMed

    Ley, C; Mohar, A; Guarner, J; Herrera-Goepfert, R; Figueroa, L S; Halperin, D; Parsonnet, J

    2001-02-01

    Intestinal-type gastric adenocarcinomas usually are preceded by chronic atrophic gastritis. Studies of gastric cancer prevention often rely on identification of this condition. In a clinical trial, we sought to determine the best serological screening method for chronic atrophic gastritis and compared our findings to the published literature. Test characteristics of potential screening tests (antibodies to Helicobacter pyloni or CagA, elevated gastrin, low pepsinogen, increased age) alone or in combination were examined among consecutive subjects enrolled in a study of H. pylori and preneoplastic gastric lesions in Chiapas, Mexico; 70% had chronic atrophic gastritis. English-language articles concerning screening for chronic atrophic gastritis were also reviewed. Sensitivity for chronic atrophic gastritis was highest for antibodies to H. pylori (92%) or CagA, or gastrin levels >25 ng/l (both 83%). Specificity, however, was low for these tests (18, 41, and 22%, respectively). Pepsinogen levels were highly specific but insensitive markers of chronic atrophic gastritis (for pepsinogen I <25 microg/l, sensitivity was 6% and specificity was 100%; for pepsinogen I:pepsinogen II ratio <2.5, sensitivity was 14% and specificity was 96%). Combinations of markers did not improve test characteristics. Screening test characteristics from the literature varied widely and did not consistently identify a good screening strategy. In this study, CagA antibodies alone had the best combination of test characteristics for chronic atrophic gastritis screening. However, no screening test was both highly sensitive and highly specific for chronic atrophic gastritis.

  14. Colorectal Cancer Screening Programme in Spain: Results of Key Performance Indicators After Five Rounds (2000-2012).

    PubMed

    Binefa, Gemma; Garcia, Montse; Milà, Núria; Fernández, Esteve; Rodríguez-Moranta, Francisco; Gonzalo, Núria; Benito, Llúcia; Clopés, Ana; Guardiola, Jordi; Moreno, Víctor

    2016-01-20

    Effective quality assurance is essential in any screening programme. This article provides a unique insight into key quality indicators of five rounds of the first population-based colorectal cancer screening programme implemented in Spain (2000-2012), providing the results according to the type of screening (prevalent or first screen and incident or subsequent screen) and test (guaiac or immunochemical). The total crude participation rate increased from 17.2% (11,011) in the first round to 35.9% (22,988) in the last one. Rescreening rate was very high (88.6% in the fifth round). Positivity rate was superior with the faecal immunochemical test (6.2%) than with the guaiac-based test (0.7%) (p < 0.0001) and detection rates were also better with the immunochemical test. The most significant rise in detection rate was observed for high risk adenoma in men (45.5 per 1,000 screened). Most cancers were diagnosed at an early stage (61.4%) and there was a statistically significant difference between those detected in first or subsequent screening (52.6% and 70.0% respectively; p = 0.024). The availability of these results substantially improves data comparisons and the exchange of experience between screening programmes.

  15. Testing the tests--an empirical evaluation of screening tests for the detection of cognitive impairment in aviators.

    PubMed

    Stokes, A F; Banich, M T; Elledge, V C

    1991-08-01

    The FAA has expressed concern that flight safety could be compromised by undetected cognitive impairment in pilots due to conditions such as substance abuse, mental illness, and neuropsychological problems. Interest has been shown in the possibility of adding a brief "mini-mental exam," or a simple automated test-battery to the standard flight medical to screen for such conditions. The research reported here involved the empirical evaluation of two "mini-mental exams," two paper-and-pencil test batteries, and a prototype version of an automated screening battery. Sensitivity, specificity, and positive predictive value were calculated for each sub-task in a discriminant study of 54 pilots and 62 individuals from a heterogeneous clinical population. Results suggest that the "mini-mental exams" are poor candidates for a screening test. The automated battery showed the best discrimination performance, in part because of the incorporation of dual-task tests of divided attention performance. These tests appear to be particularly sensitive to otherwise difficult-to-detect cognitive impairments of a mild or subtle nature. The use of an automated battery of tests as a screening instrument does appear to be feasible in principle, but the practical success of a screening program is heavily dependent upon the actual prevalence of cognitive impairment in the medical applicant population.

  16. Many-body formulation of carriers capture time in quantum dots applicable in device simulation codes

    NASA Astrophysics Data System (ADS)

    Vallone, Marco

    2010-03-01

    We present an application of Green's functions formalism to calculate in a simplified but rigorous way electrons and holes capture time in quantum dots in closed form as function of carrier density, levels confinement potential, and temperature. Carrier-carrier (Auger) scattering and single LO-phonon emission are both addressed accounting for dynamic effects of the potential screening in the single plasmon pole approximation of the dielectric function. Regarding the LO-phonons interaction, the formulation evidences the role of the dynamic screening from wetting-layer carriers in comparison with its static limit, describes the interplay between screening and Fermi band filling, and offers simple expressions for capture time, suitable for modeling implementation.

  17. Structure of the screening layer near a plane isolated body in the deep vacuum. Part 2. Monoenergetic isotropic flow

    NASA Astrophysics Data System (ADS)

    Gunko, Yuri F.; Gunko, Natalia A.

    2018-05-01

    In this paper we consider the problem of determining the structure of the electric field near the surface of a flat insulated body under conditions of a deep vacuum. It is assumed that the emitted particles are electrons leaving the body surface under the influence of ionizing radiation whose velocities distribution near the surface is isotropic. It is estimated the thickness of the screening layer under conditions of stationary emission from a flat surface. The solutio of the problem of determining a stationary self-consistent electric field near the surface is found in a simple analytical form. The thickness of the screening layer is calculated from this formula.

  18. Bias in estimating accuracy of a binary screening test with differential disease verification

    PubMed Central

    Brinton, John T.; Ringham, Brandy M.; Glueck, Deborah H.

    2011-01-01

    SUMMARY Sensitivity, specificity, positive and negative predictive value are typically used to quantify the accuracy of a binary screening test. In some studies it may not be ethical or feasible to obtain definitive disease ascertainment for all subjects using a gold standard test. When a gold standard test cannot be used an imperfect reference test that is less than 100% sensitive and specific may be used instead. In breast cancer screening, for example, follow-up for cancer diagnosis is used as an imperfect reference test for women where it is not possible to obtain gold standard results. This incomplete ascertainment of true disease, or differential disease verification, can result in biased estimates of accuracy. In this paper, we derive the apparent accuracy values for studies subject to differential verification. We determine how the bias is affected by the accuracy of the imperfect reference test, the percent who receive the imperfect reference standard test not receiving the gold standard, the prevalence of the disease, and the correlation between the results for the screening test and the imperfect reference test. It is shown that designs with differential disease verification can yield biased estimates of accuracy. Estimates of sensitivity in cancer screening trials may be substantially biased. However, careful design decisions, including selection of the imperfect reference test, can help to minimize bias. A hypothetical breast cancer screening study is used to illustrate the problem. PMID:21495059

  19. Missed connections: Unintended consequences of updated cervical cancer screening guidelines on screening rates for sexually transmitted infections.

    PubMed

    Bogler, Tali; Farber, Allison; Stall, Nathan; Wijayasinghe, Sheila; Slater, Morgan; Guiang, Charlie; Glazier, Richard H

    2015-10-01

    To examine the effects of the updated 2012 cervical cancer screening guidelines on the rates of sexually transmitted infection (STI) screening in primary care. Retrospective chart review. Five academic family practice units at St Michael's Hospital in Toronto, Ont. Female patients, aged 19 to 25, who had at least 1 visit with a physician at 1 of the 5 academic family practice units during a 12-month period before (May 1, 2011, to April 30, 2012) or after (November 1, 2012, to October 31, 2013) the release of the updated guidelines. Number of women who received Papanicolaou tests or underwent STI screening; rates of STI screening performed during a Pap test or a periodic health examination; screening rates for HIV, syphilis, and hepatitis C; and the methods used for STI screening before and after the release of the updated guidelines. Results Before the release of the 2012 guidelines, 42 of 100 women had Pap tests and 40 of 100 women underwent STI screening. After the release of the guidelines, 17 of 100 women had Pap tests and 20 of 100 women received STI screening. Female patients were less likely to undergo STI screening under the 2012 guidelines compared with the 2005 guidelines (odds ratio 0.38, 95% CI 0.19 to 0.74; P = .003). Implementation of the 2012 cervical cancer screening guidelines was associated with lower rates of STI screening in the primary care setting. Primary care physicians should screen at-risk women for STIs at any clinically appropriate encounter and consider using noninvasive self-sampling methods.

  20. Screening for cognitive impairment in the elderly.

    PubMed Central

    Bush, C.; Kozak, J.; Elmslie, T.

    1997-01-01

    OBJECTIVE: To evaluate the extent and type of screening for cognitive impairment primary care physicians use for their elderly patients, to identify perceived barriers to screening, and to explore whether physicians would be willing to use the clock drawing test as a cognitive screening tool. DESIGN: Mailed questionnaire. SETTING: Primary care practices in the Ottawa-Carleton region. PARTICIPANTS: Family physicians and general practitioners culled from the Yellow Pages and Canadian Medical Directory; 368 of 568 questionnaires were returned for a response rate of 70%. Six respondents had fewer than 30 patients weekly and two responded too late to be included in the analysis; 360 cases were included in the analysis. MAIN OUTCOME MEASURES: Responses to 10 questions on cognitive screening and five on demographics and the nature of respondents' practices. RESULTS: About 80% of respondents reported doing at least one mental status examination during the past year. Only 24% routinely screened patients, although 82% believed screening was needed. Major barriers to cognitive screening were lack of time, risk of offending patients, and possible negative consequences of follow up. Clock drawing was perceived as an acceptable method of screening, if it were proven effective. CONCLUSIONS: Most primary care physicians believe cognitive screening is needed, but few routinely screen their elderly patients. Lack of time is the most important perceived barrier to screening. Primary care physicians are receptive to using the clock drawing test, and, because it is not time-consuming, are less likely to consider lack of time a barrier to testing. The clock test might help bridge the gap between perceived need for screening and actual screening. PMID:9356757

Top