DOE Office of Scientific and Technical Information (OSTI.GOV)
Craciunescu, Teddy, E-mail: teddy.craciunescu@jet.uk; Tiseanu, Ion; Zoita, Vasile
The Joint European Torus (JET) neutron profile monitor ensures 2D coverage of the gamma and neutron emissive region that enables tomographic reconstruction. Due to the availability of only two projection angles and to the coarse sampling, tomographic inversion is a limited data set problem. Several techniques have been developed for tomographic reconstruction of the 2-D gamma and neutron emissivity on JET, but the problem of evaluating the errors associated with the reconstructed emissivity profile is still open. The reconstruction technique based on the maximum likelihood principle, that proved already to be a powerful tool for JET tomography, has been usedmore » to develop a method for the numerical evaluation of the statistical properties of the uncertainties in gamma and neutron emissivity reconstructions. The image covariance calculation takes into account the additional techniques introduced in the reconstruction process for tackling with the limited data set (projection resampling, smoothness regularization depending on magnetic field). The method has been validated by numerically simulations and applied to JET data. Different sources of artefacts that may significantly influence the quality of reconstructions and the accuracy of variance calculation have been identified.« less
NASA Astrophysics Data System (ADS)
Tornai, Martin P.; Bowsher, James E.; Archer, Caryl N.; Peter, Jörg; Jaszczak, Ronald J.; MacDonald, Lawrence R.; Patt, Bradley E.; Iwanczyk, Jan S.
2003-01-01
A novel tomographic gantry was designed, built and initially evaluated for single photon emission imaging of metabolically active lesions in the pendant breast and near chest wall. Initial emission imaging measurements with breast lesions of various uptake ratios are presented. Methods: A prototype tomograph was constructed utilizing a compact gamma camera having a field-of-view of <13×13 cm 2 with arrays of 2×2×6 mm 3 quantized NaI(Tl) scintillators coupled to position sensitive PMTs. The camera was mounted on a radially oriented support with 6 cm variable radius-of-rotation. This unit is further mounted on a goniometric cradle providing polar motion, and in turn mounted on an azimuthal rotation stage capable of indefinite vertical axis-of-rotation about the central rotation axis (RA). Initial measurements with isotopic Tc-99 m (140 keV) to evaluate the system include acquisitions with various polar tilt angles about the RA. Tomographic measurements were made of a frequency and resolution cold-rod phantom filled with aqueous Tc-99 m. Tomographic and planar measurements of 0.6 and 1.0 cm diameter fillable spheres in an available ˜950 ml hemi-ellipsoidal (uncompressed) breast phantom attached to a life-size anthropomorphic torso phantom with lesion:breast-and-body:cardiac-and-liver activity concentration ratios of 11:1:19 were compared. Various photopeak energy windows from 10-30% widths were obtained, along with a 35% scatter window below a 15% photopeak window from the list mode data. Projections with all photopeak window and camera tilt conditions were reconstructed with an ordered subsets expectation maximization (OSEM) algorithm capable of reconstructing arbitrary tomographic orbits. Results: As iteration number increased for the tomographically measured data at all polar angles, contrasts increased while signal-to-noise ratios (SNRs) decreased in the expected way with OSEM reconstruction. The rollover between contrast improvement and SNR degradation of the lesion occurred at two to three iterations. The reconstructed tomographic data yielded SNRs with or without scatter correction that were >9 times better than the planar scans. There was up to a factor of ˜2.5 increase in total primary and scatter contamination in the photopeak window with increasing tilt angle from 15° to 45°, consistent with more direct line-of-sight of myocardial and liver activity with increased camera polar angle. Conclusion: This new, ultra-compact, dedicated tomographic imaging system has the potential of providing valuable, fully 3D functional information about small, otherwise indeterminate breast lesions as an adjunct to diagnostic mammography.
Yoon, Seo Yeon; Kim, Je-Kyung; An, Young-Sil; Kim, Yong Wook
2015-01-01
Aphasia is one of the most common neurologic deficits occurring after stroke. Although the speech-language therapy is a mainstream option for poststroke aphasia, pharmacotherapy is recently being tried to modulate different neurotransmitter systems. However, the efficacy of those treatments is still controversial. We present a case of a 53-year-old female patient with Wernicke aphasia, after the old infarction in the territory of left middle cerebral artery for 8 years and the recent infarction in the right middle cerebral artery for 4 months. On the initial evaluation, the Aphasia Quotient in Korean version of the Western Aphasia Battery was 25.6 of 100. Baseline brain F-18 fluorodeoxyglucose positron emission tomographic images demonstrated a decreased cerebral metabolism in the left temporoparietal area and right temporal lobe. Donepezil hydrochloride, a reversible acetylcholinesterase inhibitor, was orally administered 5 mg/d for 6 weeks after the initial evaluation and was increased to 10 mg/d for the following 6 weeks. After the donepezil treatment, the patient showed improvement in language function, scoring 51.0 of 100 on Aphasia Quotient. A subtraction analysis of the brain F-18 fluorodeoxyglucose positron emission tomographic images after donepezil medication demonstrated increased uptake in both middle temporal gyri, extended to the occipital area and the left cerebellum. Thus, we suggest that donepezil can be an effective therapeutic choice for the treatment of Wernicke aphasia.
SSULI/SSUSI UV Tomographic Images of Large-Scale Plasma Structuring
NASA Astrophysics Data System (ADS)
Hei, M. A.; Budzien, S. A.; Dymond, K.; Paxton, L. J.; Schaefer, R. K.; Groves, K. M.
2015-12-01
We present a new technique that creates tomographic reconstructions of atmospheric ultraviolet emission based on data from the Special Sensor Ultraviolet Limb Imager (SSULI) and the Special Sensor Ultraviolet Spectrographic Imager (SSUSI), both flown on the Defense Meteorological Satellite Program (DMSP) Block 5D3 series satellites. Until now, the data from these two instruments have been used independently of each other. The new algorithm combines SSULI/SSUSI measurements of 135.6 nm emission using the tomographic technique; the resultant data product - whole-orbit reconstructions of atmospheric volume emission within the satellite orbital plane - is substantially improved over the original data sets. Tests using simulated atmospheric emission verify that the algorithm performs well in a variety of situations, including daytime, nighttime, and even in the challenging terminator regions. A comparison with ALTAIR radar data validates that the volume emission reconstructions can be inverted to yield maps of electron density. The algorithm incorporates several innovative new features, including the use of both SSULI and SSUSI data to create tomographic reconstructions, the use of an inversion algorithm (Richardson-Lucy; RL) that explicitly accounts for the Poisson statistics inherent in optical measurements, and a pseudo-diffusion based regularization scheme implemented between iterations of the RL code. The algorithm also explicitly accounts for extinction due to absorption by molecular oxygen.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ceglio, N.M.; George, E.V.; Brooks, K.M.
The first successful demonstration of high resolution, tomographic imaging of a laboratory plasma using coded imaging techniques is reported. ZPCI has been used to image the x-ray emission from laser compressed DT filled microballoons. The zone plate camera viewed an x-ray spectral window extending from below 2 keV to above 6 keV. It exhibited a resolution approximately 8 ..mu..m, a magnification factor approximately 13, and subtended a radiation collection solid angle at the target approximately 10/sup -2/ sr. X-ray images using ZPCI were compared with those taken using a grazing incidence reflection x-ray microscope. The agreement was excellent. In addition,more » the zone plate camera produced tomographic images. The nominal tomographic resolution was approximately 75 ..mu..m. This allowed three dimensional viewing of target emission from a single shot in planar ''slices''. In addition to its tomographic capability, the great advantage of the coded imaging technique lies in its applicability to hard (greater than 10 keV) x-ray and charged particle imaging. Experiments involving coded imaging of the suprathermal x-ray and high energy alpha particle emission from laser compressed microballoon targets are discussed.« less
Tomographic inversion of satellite photometry. II
NASA Technical Reports Server (NTRS)
Solomon, S. C.; Hays, P. B.; Abreu, V. J.
1985-01-01
A method for combining nadir observations of emission features in the upper atmosphere with the result of a tomographic inversion of limb brightness measurements is presented. Simulated and actual results are provided, and error sensitivity is investigated.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bielecki, J.; Scholz, M.; Drozdowicz, K.
A method of tomographic reconstruction of the neutron emissivity in the poloidal cross section of the Joint European Torus (JET, Culham, UK) tokamak was developed. Due to very limited data set (two projection angles, 19 lines of sight only) provided by the neutron emission profile monitor (KN3 neutron camera), the reconstruction is an ill-posed inverse problem. The aim of this work consists in making a contribution to the development of reliable plasma tomography reconstruction methods that could be routinely used at JET tokamak. The proposed method is based on Phillips-Tikhonov regularization and incorporates a priori knowledge of the shape ofmore » normalized neutron emissivity profile. For the purpose of the optimal selection of the regularization parameters, the shape of normalized neutron emissivity profile is approximated by the shape of normalized electron density profile measured by LIDAR or high resolution Thomson scattering JET diagnostics. In contrast with some previously developed methods of ill-posed plasma tomography reconstruction problem, the developed algorithms do not include any post-processing of the obtained solution and the physical constrains on the solution are imposed during the regularization process. The accuracy of the method is at first evaluated by several tests with synthetic data based on various plasma neutron emissivity models (phantoms). Then, the method is applied to the neutron emissivity reconstruction for JET D plasma discharge #85100. It is demonstrated that this method shows good performance and reliability and it can be routinely used for plasma neutron emissivity reconstruction on JET.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pablant, N. A.; Bell, R. E.; Bitter, M.
2014-11-15
Accurate tomographic inversion is important for diagnostic systems on stellarators and tokamaks which rely on measurements of line integrated emission spectra. A tomographic inversion technique based on spline optimization with enforcement of constraints is described that can produce unique and physically relevant inversions even in situations with noisy or incomplete input data. This inversion technique is routinely used in the analysis of data from the x-ray imaging crystal spectrometer (XICS) installed at the Large Helical Device. The XICS diagnostic records a 1D image of line integrated emission spectra from impurities in the plasma. Through the use of Doppler spectroscopy andmore » tomographic inversion, XICS can provide profile measurements of the local emissivity, temperature, and plasma flow. Tomographic inversion requires the assumption that these measured quantities are flux surface functions, and that a known plasma equilibrium reconstruction is available. In the case of low signal levels or partial spatial coverage of the plasma cross-section, standard inversion techniques utilizing matrix inversion and linear-regularization often cannot produce unique and physically relevant solutions. The addition of physical constraints, such as parameter ranges, derivative directions, and boundary conditions, allow for unique solutions to be reliably found. The constrained inversion technique described here utilizes a modified Levenberg-Marquardt optimization scheme, which introduces a condition avoidance mechanism by selective reduction of search directions. The constrained inversion technique also allows for the addition of more complicated parameter dependencies, for example, geometrical dependence of the emissivity due to asymmetries in the plasma density arising from fast rotation. The accuracy of this constrained inversion technique is discussed, with an emphasis on its applicability to systems with limited plasma coverage.« less
Pablant, N. A.; Bell, R. E.; Bitter, M.; ...
2014-08-08
Accurate tomographic inversion is important for diagnostic systems on stellarators and tokamaks which rely on measurements of line integrated emission spectra. A tomographic inversion technique based on spline optimization with enforcement of constraints is described that can produce unique and physically relevant inversions even in situations with noisy or incomplete input data. This inversion technique is routinely used in the analysis of data from the x-ray imaging crystal spectrometer (XICS) installed at LHD. The XICS diagnostic records a 1D image of line integrated emission spectra from impurities in the plasma. Through the use of Doppler spectroscopy and tomographic inversion, XICSmore » can provide pro file measurements of the local emissivity, temperature and plasma flow. Tomographic inversion requires the assumption that these measured quantities are flux surface functions, and that a known plasma equilibrium reconstruction is available. In the case of low signal levels or partial spatial coverage of the plasma cross-section, standard inversion techniques utilizing matrix inversion and linear-regularization often cannot produce unique and physically relevant solutions. The addition of physical constraints, such as parameter ranges, derivative directions, and boundary conditions, allow for unique solutions to be reliably found. The constrained inversion technique described here utilizes a modifi ed Levenberg-Marquardt optimization scheme, which introduces a condition avoidance mechanism by selective reduction of search directions. The constrained inversion technique also allows for the addition of more complicated parameter dependencies, for example geometrical dependence of the emissivity due to asymmetries in the plasma density arising from fast rotation. The accuracy of this constrained inversion technique is discussed, with an emphasis on its applicability to systems with limited plasma coverage.« less
Tomographic Image Compression Using Multidimensional Transforms.
ERIC Educational Resources Information Center
Villasenor, John D.
1994-01-01
Describes a method for compressing tomographic images obtained using Positron Emission Tomography (PET) and Magnetic Resonance (MR) by applying transform compression using all available dimensions. This takes maximum advantage of redundancy of the data, allowing significant increases in compression efficiency and performance. (13 references) (KRN)
NASA Technical Reports Server (NTRS)
Mcdade, Ian C.
1991-01-01
Techniques were developed for recovering two-dimensional distributions of auroral volume emission rates from rocket photometer measurements made in a tomographic spin scan mode. These tomographic inversion procedures are based upon an algebraic reconstruction technique (ART) and utilize two different iterative relaxation techniques for solving the problems associated with noise in the observational data. One of the inversion algorithms is based upon a least squares method and the other on a maximum probability approach. The performance of the inversion algorithms, and the limitations of the rocket tomography technique, were critically assessed using various factors such as (1) statistical and non-statistical noise in the observational data, (2) rocket penetration of the auroral form, (3) background sources of emission, (4) smearing due to the photometer field of view, and (5) temporal variations in the auroral form. These tests show that the inversion procedures may be successfully applied to rocket observations made in medium intensity aurora with standard rocket photometer instruments. The inversion procedures have been used to recover two-dimensional distributions of auroral emission rates and ionization rates from an existing set of N2+3914A rocket photometer measurements which were made in a tomographic spin scan mode during the ARIES auroral campaign. The two-dimensional distributions of the 3914A volume emission rates recoverd from the inversion of the rocket data compare very well with the distributions that were inferred from ground-based measurements using triangulation-tomography techniques and the N2 ionization rates derived from the rocket tomography results are in very good agreement with the in situ particle measurements that were made during the flight. Three pre-prints describing the tomographic inversion techniques and the tomographic analysis of the ARIES rocket data are included as appendices.
Singh, Parmanand; Emami, Hamed; Subramanian, Sharath; Maurovich-Horvat, Pal; Marincheva-Savcheva, Gergana; Medina, Hector M; Abdelbaky, Amr; Alon, Achilles; Shankar, Sudha S; Rudd, James H F; Fayad, Zahi A; Hoffmann, Udo; Tawakol, Ahmed
2016-12-01
Nonobstructive coronary plaques manifesting high-risk morphology (HRM) associate with an increased risk of adverse clinical cardiovascular events. We sought to test the hypothesis that statins have a greater anti-inflammatory effect within coronary plaques containing HRM. In this prospective multicenter study, 55 subjects with or at high risk for atherosclerosis underwent 18 F-fluorodeoxyglucose positron emission tomographic/computed tomographic imaging at baseline and after 12 weeks of treatment with atorvastatin. Coronary arterial inflammation ( 18 F-fluorodeoxyglucose uptake, expressed as target-to-background ratio) was assessed in the left main coronary artery (LMCA). While blinded to the PET findings, contrast-enhanced computed tomographic angiography was performed to characterize the presence of HRM (defined as noncalcified or partially calcified plaques) in the LMCA. Arterial inflammation (target-to-background ratio) was higher in LMCA segments with HRM than those without HRM (mean±SEM: 1.95±0.43 versus 1.67±0.32 for LMCA with versus without HRM, respectively; P=0.04). Moreover, atorvastatin treatment for 12 weeks reduced target-to-background ratio more in LMCA segments with HRM than those without HRM (12 week-baseline Δtarget-to-background ratio [95% confidence interval]: -0.18 [-0.35 to -0.004] versus 0.09 [-0.06 to 0.26]; P=0.02). Furthermore, this relationship between coronary plaque morphology and change in LMCA inflammatory activity remained significant after adjusting for baseline low-density lipoprotein and statin dose (β=-0.27; P=0.038). In this first study to evaluate the impact of statins on coronary inflammation, we observed that the anti-inflammatory impact of statins is substantially greater within coronary plaques that contain HRM features. These findings suggest an additional mechanism by which statins disproportionately benefit individuals with more advanced atherosclerotic disease. URL: http://www.clinicaltrials.gov. Unique identifier: NCT00703261. © 2016 The Authors.
A 3D tomographic reconstruction method to analyze Jupiter's electron-belt emission observations
NASA Astrophysics Data System (ADS)
Santos-Costa, Daniel; Girard, Julien; Tasse, Cyril; Zarka, Philippe; Kita, Hajime; Tsuchiya, Fuminori; Misawa, Hiroaki; Clark, George; Bagenal, Fran; Imai, Masafumi; Becker, Heidi N.; Janssen, Michael A.; Bolton, Scott J.; Levin, Steve M.; Connerney, John E. P.
2017-04-01
Multi-dimensional reconstruction techniques of Jupiter's synchrotron radiation from radio-interferometric observations were first developed by Sault et al. [Astron. Astrophys., 324, 1190-1196, 1997]. The tomographic-like technique introduced 20 years ago had permitted the first 3-dimensional mapping of the brightness distribution around the planet. This technique has demonstrated the advantage to be weakly dependent on planetary field models. It also does not require any knowledge on the energy and spatial distributions of the radiating electrons. On the downside, it is assumed that the volume emissivity of any punctual point source around the planet is isotropic. This assumption becomes incorrect when mapping the brightness distribution for non-equatorial point sources or any point sources from Juno's perspective. In this paper, we present our modeling effort to bypass the isotropy issue. Our approach is to use radio-interferometric observations and determine the 3-D brightness distribution in a cylindrical coordinate system. For each set (z, r), we constrain the longitudinal distribution with a Fourier series and the anisotropy is addressed with a simple periodic function when possible. We develop this new method over a wide range of frequencies using past VLA and LOFAR observations of Jupiter. We plan to test this reconstruction method with observations of Jupiter that are currently being carried out with LOFAR and GMRT in support to the Juno mission. We describe how this new 3D tomographic reconstruction method provides new model constraints on the energy and spatial distributions of Jupiter's ultra-relativistic electrons close to the planet and be used to interpret Juno MWR observations of Jupiter's electron-belt emission and assist in evaluating the background noise from the radiation environment in the atmospheric measurements.
Cardiac metastases of Ewing sarcoma detected by 18F-FDG PET/CT.
Coccia, Paola; Ruggiero, Antonio; Rufini, Vittoria; Maurizi, Palma; Attinà, Giorgio; Marano, Riccardo; Natale, Luigi; Leccisotti, Lucia; Calcagni, Maria L; Riccardi, Riccardo
2012-04-01
Positron emission tomography (PET) is widely used in the diagnostic evaluation and staging of different malignant tumors. The role of PET/computed tomographic scan in detecting distant metastases in the workup of Ewing sarcoma in children or young adults is less well defined. We report a case of a boy affected by a metastatic Ewing sarcoma with cardiac asymptomatic metastasis detected by F-FDG PET/computed tomography.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jacobsson-Svard, Staffan; Smith, Leon E.; White, Timothy
The potential for gamma emission tomography (GET) to detect partial defects within a spent nuclear fuel assembly has been assessed within the IAEA Support Program project JNT 1955, phase I, which was completed and reported to the IAEA in October 2016. Two safeguards verification objectives were identified in the project; (1) independent determination of the number of active pins that are present in a measured assembly, in the absence of a priori information about the assembly; and (2) quantitative assessment of pin-by-pin properties, for example the activity of key isotopes or pin attributes such as cooling time and relative burnup,more » under the assumption that basic fuel parameters (e.g., assembly type and nominal fuel composition) are known. The efficacy of GET to meet these two verification objectives was evaluated across a range of fuel types, burnups and cooling times, while targeting a total interrogation time of less than 60 minutes. The evaluations were founded on a modelling and analysis framework applied to existing and emerging GET instrument designs. Monte Carlo models of different fuel types were used to produce simulated tomographer responses to large populations of “virtual” fuel assemblies. The simulated instrument response data were then processed using a variety of tomographic-reconstruction and image-processing methods, and scoring metrics were defined and used to evaluate the performance of the methods.This paper describes the analysis framework and metrics used to predict tomographer performance. It also presents the design of a “universal” GET (UGET) instrument intended to support the full range of verification scenarios envisioned by the IAEA. Finally, it gives examples of the expected partial-defect detection capabilities for some fuels and diversion scenarios, and it provides a comparison of predicted performance for the notional UGET design and an optimized variant of an existing IAEA instrument.« less
New Possibilities of Positron-Emission Tomography
NASA Astrophysics Data System (ADS)
Volobuev, A. N.
2018-01-01
The reasons for the emergence of the angular distribution of photons generated as a result of annihilation of an electron and a positron in a positron-emission tomograph are investigated. It is shown that the angular distribution of the radiation intensity (i.e., the probability of photon emission at different angles) is a consequence of the Doppler effect in the center-of-mass reference system of the electron and the positron. In the reference frame attached to the electron, the angular distribution of the number of emitted photons does not exists but is replaced by the Doppler shift of the frequency of photons. The results obtained in this study make it possible to extend the potentialities of the positron-emission tomograph in the diagnostics of diseases and to obtain additional mechanical characteristics of human tissues, such as density and viscosity.
Positron Emission Tomography: Principles, Technology, and Recent Developments
NASA Astrophysics Data System (ADS)
Ziegler, Sibylle I.
2005-04-01
Positron emission tomography (PET) is a nuclear medical imaging technique for quantitative measurement of physiologic parameters in vivo (an overview of principles and applications can be found in [P.E. Valk, et al., eds. Positron Emission Tomography. Basic Science and Clinical Practice. 2003, Springer: Heidelberg]), based on the detection of small amounts of posi-tron-emitter-labelled biologic molecules. Various radiotracers are available for neuro-logical, cardiological, and oncological applications in the clinic and in research proto-cols. This overview describes the basic principles, technology, and recent develop-ments in PET, followed by a section on the development of a tomograph with ava-lanche photodiodes dedicated for small animal imaging as an example of efforts in the domain of high resolution tomographs.
Data analysis in emission tomography using emission-count posteriors
NASA Astrophysics Data System (ADS)
Sitek, Arkadiusz
2012-11-01
A novel approach to the analysis of emission tomography data using the posterior probability of the number of emissions per voxel (emission count) conditioned on acquired tomographic data is explored. The posterior is derived from the prior and the Poisson likelihood of the emission-count data by marginalizing voxel activities. Based on emission-count posteriors, examples of Bayesian analysis including estimation and classification tasks in emission tomography are provided. The application of the method to computer simulations of 2D tomography is demonstrated. In particular, the minimum-mean-square-error point estimator of the emission count is demonstrated. The process of finding this estimator can be considered as a tomographic image reconstruction technique since the estimates of the number of emissions per voxel divided by voxel sensitivities and acquisition time are the estimates of the voxel activities. As an example of a classification task, a hypothesis stating that some region of interest (ROI) emitted at least or at most r-times the number of events in some other ROI is tested. The ROIs are specified by the user. The analysis described in this work provides new quantitative statistical measures that can be used in decision making in diagnostic imaging using emission tomography.
Classification of JET Neutron and Gamma Emissivity Profiles
NASA Astrophysics Data System (ADS)
Craciunescu, T.; Murari, A.; Kiptily, V.; Vega, J.; Contributors, JET
2016-05-01
In thermonuclear plasmas, emission tomography uses integrated measurements along lines of sight (LOS) to determine the two-dimensional (2-D) spatial distribution of the volume emission intensity. Due to the availability of only a limited number views and to the coarse sampling of the LOS, the tomographic inversion is a limited data set problem. Several techniques have been developed for tomographic reconstruction of the 2-D gamma and neutron emissivity on JET. In specific experimental conditions the availability of LOSs is restricted to a single view. In this case an explicit reconstruction of the emissivity profile is no longer possible. However, machine learning classification methods can be used in order to derive the type of the distribution. In the present approach the classification is developed using the theory of belief functions which provide the support to fuse the results of independent clustering and supervised classification. The method allows to represent the uncertainty of the results provided by different independent techniques, to combine them and to manage possible conflicts.
Representation of photon limited data in emission tomography using origin ensembles
NASA Astrophysics Data System (ADS)
Sitek, A.
2008-06-01
Representation and reconstruction of data obtained by emission tomography scanners are challenging due to high noise levels in the data. Typically, images obtained using tomographic measurements are represented using grids. In this work, we define images as sets of origins of events detected during tomographic measurements; we call these origin ensembles (OEs). A state in the ensemble is characterized by a vector of 3N parameters Y, where the parameters are the coordinates of origins of detected events in a three-dimensional space and N is the number of detected events. The 3N-dimensional probability density function (PDF) for that ensemble is derived, and we present an algorithm for OE image estimation from tomographic measurements. A displayable image (e.g. grid based image) is derived from the OE formulation by calculating ensemble expectations based on the PDF using the Markov chain Monte Carlo method. The approach was applied to computer-simulated 3D list-mode positron emission tomography data. The reconstruction errors for a 10 000 000 event acquisition for simulated ranged from 0.1 to 34.8%, depending on object size and sampling density. The method was also applied to experimental data and the results of the OE method were consistent with those obtained by a standard maximum-likelihood approach. The method is a new approach to representation and reconstruction of data obtained by photon-limited emission tomography measurements.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kramar, M.; Lin, H.; Tomczyk, S., E-mail: kramar@cua.edu, E-mail: lin@ifa.hawaii.edu, E-mail: tomczyk@ucar.edu
We present the first direct “observation” of the global-scale, 3D coronal magnetic fields of Carrington Rotation (CR) Cycle 2112 using vector tomographic inversion techniques. The vector tomographic inversion uses measurements of the Fe xiii 10747 Å Hanle effect polarization signals by the Coronal Multichannel Polarimeter (CoMP) and 3D coronal density and temperature derived from scalar tomographic inversion of Solar Terrestrial Relations Observatory (STEREO)/Extreme Ultraviolet Imager (EUVI) coronal emission lines (CELs) intensity images as inputs to derive a coronal magnetic field model that best reproduces the observed polarization signals. While independent verifications of the vector tomography results cannot be performed, wemore » compared the tomography inverted coronal magnetic fields with those constructed by magnetohydrodynamic (MHD) simulations based on observed photospheric magnetic fields of CR 2112 and 2113. We found that the MHD model for CR 2112 is qualitatively consistent with the tomography inverted result for most of the reconstruction domain except for several regions. Particularly, for one of the most noticeable regions, we found that the MHD simulation for CR 2113 predicted a model that more closely resembles the vector tomography inverted magnetic fields. In another case, our tomographic reconstruction predicted an open magnetic field at a region where a coronal hole can be seen directly from a STEREO-B/EUVI image. We discuss the utilities and limitations of the tomographic inversion technique, and present ideas for future developments.« less
System Performance Simulations of the RatCAP Awake Rat Brain Scanner
NASA Astrophysics Data System (ADS)
Shokouhi, S.; Vaska, P.; Schlyer, D. J.; Stoll, S. P.; Villanueva, A.; Kriplani, A.; Woody, C. L.
2005-10-01
The capability to create high quality images from data acquired by the Rat Conscious Animal PET tomograph (RatCAP) has been evaluated using modified versions of the PET Monte Carlo code Simulation System for Emission Tomography (SimSET). The proposed tomograph consists of lutetium oxyorthosilicate (LSO) crystals arranged in 12 4 /spl times/ 8 blocks. The effects of the RatCAPs small ring diameter (/spl sim/40 mm) and its block detector geometry on image quality for small animal studies have been investigated. Since the field of view will be almost as large as the ring diameter, radial elongation artifacts due to parallax error are expected to degrade the spatial resolution and thus the image quality at the edge of the field of view. In addition to Monte Carlo simulations, some preliminary results of experimentally acquired images in both two-dimensional (2-D) and 3-D modes are presented.
Recent Developments in Positron Emission Tomography (PET) Instrumentation
DOE R&D Accomplishments Database
Derenzo, S. E.; Budinger, T. F.
1986-04-01
This paper presents recent detector developments and perspectives for positron emission tomography (PET) instrumentation used for medical research, as well as the physical processes in positron annihilation, photon scattering and detection, tomograph design considerations, and the potentials for new advances in detectors.
The Tomographic Ionized-Carbon Mapping Experiment (TIME) CII Imaging Spectrometer
NASA Astrophysics Data System (ADS)
Staniszewski, Z.; Bock, J. J.; Bradford, C. M.; Brevik, J.; Cooray, A.; Gong, Y.; Hailey-Dunsheath, S.; O'Brient, R.; Santos, M.; Shirokoff, E.; Silva, M.; Zemcov, M.
2014-09-01
The Tomographic Ionized-Carbon Mapping Experiment (TIME) and TIME-Pilot are proposed imaging spectrometers to measure reionization and large scale structure at redshifts 5-9. We seek to exploit the 158 restframe emission of [CII], which becomes measurable at 200-300 GHz at reionization redshifts. Here we describe the scientific motivation, give an overview of the proposed instrument, and highlight key technological developments underway to enable these measurements.
The auroral 6300 A emission - Observations and modeling
NASA Technical Reports Server (NTRS)
Solomon, Stanley C.; Hays, Paul B.; Abreu, Vincent J.
1988-01-01
A tomographic inversion is used to analyze measurements of the auroral atomic oxygen emission line at 6300 A made by the atmosphere explorer visible airglow experiment. A comparison is made between emission altitude profiles and the results from an electron transport and chemical reaction model. Measurements of the energetic electron flux, neutral composition, ion composition, and electron density are incorporated in the model.
5D-intravital tomography as a novel tool for non-invasive in-vivo analysis of human skin
NASA Astrophysics Data System (ADS)
König, Karsten; Weinigel, Martin; Breunig, Hans G.; Gregory, Axel; Fischer, Peter; Kellner-Höfer, Marcel; Bückle, Rainer; Schwarz, Martin; Riemann, Iris; Stracke, Frank; Huck, Volker; Gorzelanny, Christian; Schneider, Stefan W.
2010-02-01
Some years ago, CE-marked clinical multiphoton systems for 3D imaging of human skin with subcellular resolution have been launched. These tomographs provide optical biopsies with submicron resolution based on two-photon excited autofluorescence (NAD(P)H, flavoproteins, keratin, elastin, melanin, porphyrins) and second harmonic generation by collagen. The 3D tomograph was now transferred into a 5D imaging system by the additional detection of the emission spectrum and the fluorescence lifetime based on spatially and spectrally resolved time-resolved single photon counting. The novel 5D intravital tomograph (5D-IVT) was employed for the early detection of atopic dermatitis and the analysis of treatment effects.
Yamatsuji, Tomoki; Ishida, Naomasa; Takaoka, Munenori; Hayashi, Jiro; Yoshida, Kazuhiro; Shigemitsu, Kaori; Urakami, Atsushi; Haisa, Minoru; Naomoto, Yoshio
2017-01-01
Of 129 esophagectomies at our institute from June 2010 to March 2015, we experienced three preoperative positron emission tomography-computed tomographic (PET/CT) false positives. Bone metastasis was originally suspected in 2 cases, but they were later found to be bone metastasis negative after a preoperative bone biopsy and clinical course observation. The other cases suspected of mediastinal lymph node metastasis were diagnosed as inflammatory lymphadenopathy by a pathological examination of the removed lymph nodes. Conducting a PET/CT is useful when diagnosing esophageal cancer metastasis, but we need to be aware of the possibility of false positives. Therapeutic decisions should be made based on appropriate and accurate diagnoses, with pathological diagnosis actively introduced if necessary. PMID:28469502
Imaging of turbulent structures and tomographic reconstruction of TORPEX plasma emissivity
NASA Astrophysics Data System (ADS)
Iraji, D.; Furno, I.; Fasoli, A.; Theiler, C.
2010-12-01
In the TORPEX [A. Fasoli et al., Phys. Plasmas 13, 055902 (2006)], a simple magnetized plasma device, low frequency electrostatic fluctuations associated with interchange waves, are routinely measured by means of extensive sets of Langmuir probes. To complement the electrostatic probe measurements of plasma turbulence and study of plasma structures smaller than the spatial resolution of probes array, a nonperturbative direct imaging system has been developed on TORPEX, including a fast framing Photron-APX-RS camera and an image intensifier unit. From the line-integrated camera images, we compute the poloidal emissivity profile of the plasma by applying a tomographic reconstruction technique using a pixel method and solving an overdetermined set of equations by singular value decomposition. This allows comparing statistical, spectral, and spatial properties of visible light radiation with electrostatic fluctuations. The shape and position of the time-averaged reconstructed plasma emissivity are observed to be similar to those of the ion saturation current profile. In the core plasma, excluding the electron cyclotron and upper hybrid resonant layers, the mean value of the plasma emissivity is observed to vary with (Te)α(ne)β, in which α =0.25-0.7 and β =0.8-1.4, in agreement with collisional radiative model. The tomographic reconstruction is applied to the fast camera movie acquired with 50 kframes/s rate and 2 μs of exposure time to obtain the temporal evolutions of the emissivity fluctuations. Conditional average sampling is also applied to visualize and measure sizes of structures associated with the interchange mode. The ω-time and the two-dimensional k-space Fourier analysis of the reconstructed emissivity fluctuations show the same interchange mode that is detected in the ω and k spectra of the ion saturation current fluctuations measured by probes. Small scale turbulent plasma structures can be detected and tracked in the reconstructed emissivity movies with the spatial resolution down to 2 cm, well beyond the spatial resolution of the probe array.
1987-01-01
BLOOD FLOW CHANGE Steven E. Petersen, Peter T. Fox, Michael I. Posner, Marcus Raichle McDonnell Center for Studies of Higher Brain Function...Single Words Using Positron Emission Tomographic Measurements of Cerebral Blood Flow Change *= ’I PERSONAL AUTHOR(S) * Petersen, Steven E. 13a. TYPE OF...CHANGE Steven E. Petersen, Peter T. Fox, Michael I. Posner, Marcus E. Raichle INTRODUCTION Language is an essential characteristic of the human
Counts, Sarah J; Kim, Anthony W
2017-08-01
Modalities to detect and characterize lung cancer are generally divided into those that are invasive [endobronchial ultrasound (EBUS), esophageal ultrasound (EUS), and electromagnetic navigational bronchoscopy (ENMB)] versus noninvasive [chest radiography (CXR), computed tomography (CT), positron emission tomography (PET), and magnetic resonance imaging (MRI)]. This chapter describes these modalities, the literature supporting their use, and delineates what tests to use to best evaluate the patient with lung cancer. Copyright © 2017 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Yatsishina, E. B.; Kovalchuk, M. V.; Loshak, M. D.; Vasilyev, S. V.; Vasilieva, O. A.; Dyuzheva, O. P.; Pojidaev, V. M.; Ushakov, V. L.
2018-05-01
Nine ancient Egyptian mummies (dated preliminarily to the period from the 1st mill. BCE to the first centuries CE) from the collection of the State Pushkin Museum of Fine Arts have been studied at the National Research Centre "Kurchatov Institute" (NRC KI) on the base of the complex of NBICS technologies. Tomographic scanning is performed using a magneto-resonance tomograph (3 T) and a hybrid positron emission tomography/computed tomography (PET-CT) scanner. Three-dimensional reconstructions of mummies and their anthropological measurements are carried out. Some medical conclusions are drawn based on the tomographic data. In addition, the embalming composition and tissue of one of the mummies are preliminarily analyzed.
Concurrent Ultrasonic Tomography and Acoustic Emission in Solid Materials
NASA Astrophysics Data System (ADS)
Chow, Thomas M.
A series of experiments were performed to detect stress induced changes in the elastic properties of various solid materials. A technique was developed where these changes were monitored concurrently by two methods, ultrasonic tomography and acoustic emission monitoring. This thesis discusses some experiments in which acoustic emission (AE) and ultrasonic tomography were performed on various samples of solid materials including rocks, concrete, metals, and fibre reinforced composites. Three separate techniques were used to induce stress in these samples. Disk shaped samples were subject to stress via diametral loading using an indirect tensile test geometry. Cylindrical samples of rocks and concrete were subject to hydraulic fracture tests, and rectangular samples of fibre reinforced composite were subject to direct tensile loading. The majority of the samples were elastically anisotropic. Full waveform acoustic emission and tomographic data were collected while these samples were under load to give information concerning changes in the structure of the material as it was undergoing stress change and/or failure. Analysis of this data indicates that AE and tomographic techniques mutually compliment each other to give a view of the stress induced elastic changes in the tested samples.
NASA Astrophysics Data System (ADS)
Dymond, K.; Nicholas, A. C.; Budzien, S. A.; Stephan, A. W.; Coker, C.; Hei, M. A.; Groves, K. M.
2015-12-01
The Special Sensor Ultraviolet Limb Imager (SSULI) instruments are ultraviolet limb scanning sensors flying on the Defense Meteorological Satellite Program (DMSP) satellites. The SSULIs observe the 80-170 nanometer wavelength range covering emissions at 91 and 136 nm, which are produced by radiative recombination of the ionosphere. We invert these emissions tomographically using newly developed algorithms that include optical depth effects due to pure absorption and resonant scattering. We present the details of our approach including how the optimal altitude and along-track sampling were determined and the newly developed approach we are using for regularizing the SSULI tomographic inversions. Finally, we conclude with validations of the SSULI inversions against ALTAIR incoherent scatter radar measurements and demonstrate excellent agreement between the measurements.
NASA Astrophysics Data System (ADS)
Rathore, Kavita; Bhattacharjee, Sudeep; Munshi, Prabhat
2017-06-01
A tomographic method based on the Fourier transform is used for characterizing a microwave plasma in a multicusp (MC), in order to obtain 2D distribution of plasma emissions, plasma (electron) density (Ne) and temperature (Te). The microwave plasma in the MC is characterized as a function of microwave power, gas pressure, and axial distance. The experimentally obtained 2D emission profiles show that the plasma emissions are generated in a circular ring shape. There are usually two bright rings, one at the plasma core and another near the boundary. The experimental results are validated using a numerical code that solves Maxwell's equations inside a waveguide filled with a plasma in a magnetic field, with collisions included. It is inferred that the dark and bright circular ring patterns are a result of superposition of Bessel modes (TE11 and TE21) of the wave electric field inside the plasma filled MC, which are in reasonable agreement with the plasma emission profiles. The tomographically obtained Ne and Te profiles indicate higher densities in the plasma core (˜1010 cm-3) and enhanced electron temperature in the ECR region (˜13 eV), which are in agreement with earlier results using a Langmuir probe and optical emission spectroscopy (OES) diagnostics.
Functional-Lesion Investigation of Developmental Stuttering with Positron Emission Tomography.
ERIC Educational Resources Information Center
Ingham, Roger J.; And Others
1996-01-01
Analysis of use of positron emission tomographic measurements of resting-state regional cerebral blood flow in 29 men, 10 of whom stuttered, did not support the idea that developmental stuttering is associated with abnormalities of blood flow at rest. Findings did suggest an essentially normal functional brain terrain with a small number of minor…
Imaging of turbulent structures and tomographic reconstruction of TORPEX plasma emissivity
DOE Office of Scientific and Technical Information (OSTI.GOV)
Iraji, D.; Furno, I.; Fasoli, A.
In the TORPEX [A. Fasoli et al., Phys. Plasmas 13, 055902 (2006)], a simple magnetized plasma device, low frequency electrostatic fluctuations associated with interchange waves, are routinely measured by means of extensive sets of Langmuir probes. To complement the electrostatic probe measurements of plasma turbulence and study of plasma structures smaller than the spatial resolution of probes array, a nonperturbative direct imaging system has been developed on TORPEX, including a fast framing Photron-APX-RS camera and an image intensifier unit. From the line-integrated camera images, we compute the poloidal emissivity profile of the plasma by applying a tomographic reconstruction technique usingmore » a pixel method and solving an overdetermined set of equations by singular value decomposition. This allows comparing statistical, spectral, and spatial properties of visible light radiation with electrostatic fluctuations. The shape and position of the time-averaged reconstructed plasma emissivity are observed to be similar to those of the ion saturation current profile. In the core plasma, excluding the electron cyclotron and upper hybrid resonant layers, the mean value of the plasma emissivity is observed to vary with (T{sub e}){sup {alpha}}(n{sub e}){sup {beta}}, in which {alpha}=0.25-0.7 and {beta}=0.8-1.4, in agreement with collisional radiative model. The tomographic reconstruction is applied to the fast camera movie acquired with 50 kframes/s rate and 2 {mu}s of exposure time to obtain the temporal evolutions of the emissivity fluctuations. Conditional average sampling is also applied to visualize and measure sizes of structures associated with the interchange mode. The {omega}-time and the two-dimensional k-space Fourier analysis of the reconstructed emissivity fluctuations show the same interchange mode that is detected in the {omega} and k spectra of the ion saturation current fluctuations measured by probes. Small scale turbulent plasma structures can be detected and tracked in the reconstructed emissivity movies with the spatial resolution down to 2 cm, well beyond the spatial resolution of the probe array.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rathore, Kavita, E-mail: kavira@iitk.ac.in, E-mail: pmunshi@iitk.ac.in, E-mail: sudeepb@iitk.ac.in; Munshi, Prabhat, E-mail: kavira@iitk.ac.in, E-mail: pmunshi@iitk.ac.in, E-mail: sudeepb@iitk.ac.in; Bhattacharjee, Sudeep, E-mail: kavira@iitk.ac.in, E-mail: pmunshi@iitk.ac.in, E-mail: sudeepb@iitk.ac.in
A new non-invasive diagnostic system is developed for Microwave Induced Plasma (MIP) to reconstruct tomographic images of a 2D emission profile. A compact MIP system has wide application in industry as well as research application such as thrusters for space propulsion, high current ion beams, and creation of negative ions for heating of fusion plasma. Emission profile depends on two crucial parameters, namely, the electron temperature and density (over the entire spatial extent) of the plasma system. Emission tomography provides basic understanding of plasmas and it is very useful to monitor internal structure of plasma phenomena without disturbing its actualmore » processes. This paper presents development of a compact, modular, and versatile Optical Emission Tomography (OET) tool for a cylindrical, magnetically confined MIP system. It has eight slit-hole cameras and each consisting of a complementary metal–oxide–semiconductor linear image sensor for light detection. The optical noise is reduced by using aspheric lens and interference band-pass filters in each camera. The entire cylindrical plasma can be scanned with automated sliding ring mechanism arranged in fan-beam data collection geometry. The design of the camera includes a unique possibility to incorporate different filters to get the particular wavelength light from the plasma. This OET system includes selected band-pass filters for particular argon emission 750 nm, 772 nm, and 811 nm lines and hydrogen emission H{sub α} (656 nm) and H{sub β} (486 nm) lines. Convolution back projection algorithm is used to obtain the tomographic images of plasma emission line. The paper mainly focuses on (a) design of OET system in detail and (b) study of emission profile for 750 nm argon emission lines to validate the system design.« less
Overview of the Benzene and Other Toxics Exposure (BEE-TEX) Field Study.
Olaguer, Eduardo P
2015-01-01
The Benzene and other Toxics Exposure (BEE-TEX) field study was an experimental campaign designed to demonstrate novel methods for measuring ambient concentrations of hazardous air pollutants (HAPs) in real time and to attribute these concentrations to quantified releases from specific emission points in industrial facilities while operating outside facility fence lines. BEE-TEX was conducted in February 2015 at three neighboring communities in the Houston Ship Channel of Texas, where a large number of petrochemical facilities are concentrated. The novel technologies deployed during BEE-TEX included: (1) tomographic remote sensing based on differential optical absorption spectroscopy; (2) real-time broadcasting of ambient air monitoring data over the World Wide Web; (3) real-time source attribution and quantification of HAP emissions based on either tomographic or mobile measurement platforms; and (4) the use of cultured human lung cells in vitro as portable indicators of HAP exposure.
Overview of the Benzene and Other Toxics Exposure (BEE-TEX) Field Study
Olaguer, Eduardo P.
2015-01-01
The Benzene and other Toxics Exposure (BEE-TEX) field study was an experimental campaign designed to demonstrate novel methods for measuring ambient concentrations of hazardous air pollutants (HAPs) in real time and to attribute these concentrations to quantified releases from specific emission points in industrial facilities while operating outside facility fence lines. BEE-TEX was conducted in February 2015 at three neighboring communities in the Houston Ship Channel of Texas, where a large number of petrochemical facilities are concentrated. The novel technologies deployed during BEE-TEX included: (1) tomographic remote sensing based on differential optical absorption spectroscopy; (2) real-time broadcasting of ambient air monitoring data over the World Wide Web; (3) real-time source attribution and quantification of HAP emissions based on either tomographic or mobile measurement platforms; and (4) the use of cultured human lung cells in vitro as portable indicators of HAP exposure. PMID:26549972
Feasibility of hydrogen density estimation from tomographic sensing of Lyman alpha emission
NASA Astrophysics Data System (ADS)
Waldrop, L.; Kamalabadi, F.; Ren, D.
2015-12-01
In this work, we describe the scientific motivation, basic principles, and feasibility of a new approach to the estimation of neutral hydrogen (H) density in the terrestrial exosphere based on the 3-D tomographic sensing of optically thin H emission at 121.6 nm (Lyman alpha). In contrast to existing techniques, Lyman alpha tomography allows for model-independent reconstruction of the underlying H distribution in support of investigations regarding the origin and time-dependent evolution of exospheric structure. We quantitatively describe the trade-off space between the measurement sampling rate, viewing geometry, and the spatial and temporal resolution of the reconstruction that is supported by the data. We demonstrate that this approach is feasible from either earth-orbiting satellites such as the stereoscopic NASA TWINS mission or from a CubeSat platform along a trans-exosphere trajectory such as that enabled by the upcoming Exploration Mission 1 launch.
Ultrasoft x-ray imaging system for the National Spherical Torus Experiment
NASA Astrophysics Data System (ADS)
Stutman, D.; Finkenthal, M.; Soukhanovskii, V.; May, M. J.; Moos, H. W.; Kaita, R.
1999-01-01
A spectrally resolved ultrasoft x-ray imaging system, consisting of arrays of high resolution (<2 Å) and throughput (⩾tens of kHz) miniature monochromators, and based on multilayer mirrors and absolute photodiodes, is being designed for the National Spherical Torus Experiment. Initially, three poloidal arrays of diodes filtered for C 1s-np emission will be implemented for fast tomographic imaging of the colder start-up plasmas. Later on, mirrors tuned to the C Lyα emission will be added in order to enable the arrays to "see" the periphery through the hot core and to study magnetohydrodynamic activity and impurity transport in this region. We also discuss possible core diagnostics, based on tomographic imaging of the Lyα emission from the plume of recombined, low Z impurity ions left by neutral beams or fueling pellets. The arrays can also be used for radiated power measurements and to map the distribution of high Z impurities injected for transport studies. The performance of the proposed system is illustrated with results from test channels on the CDX-U spherical torus at Princeton Plasma Physics Laboratory.
Photoacoustic imaging of fluorophores using pump-probe excitation
Märk, Julia; Schmitt, Franz-Josef; Theiss, Christoph; Dortay, Hakan; Friedrich, Thomas; Laufer, Jan
2015-01-01
A pump-probe technique for the detection of fluorophores in tomographic PA images is introduced. It is based on inducing stimulated emission in fluorescent molecules, which in turn modulates the amount of thermalized energy, and hence the PA signal amplitude. A theoretical model of the PA signal generation in fluorophores is presented and experimentally validated on cuvette measurements made in solutions of Rhodamine 6G, a fluorophore of known optical and molecular properties. The application of this technique to deep tissue tomographic PA imaging is demonstrated by determining the spatial distribution of a near-infrared fluorophore in a tissue phantom. PMID:26203378
DOE Office of Scientific and Technical Information (OSTI.GOV)
Laughlin, J.S.; Benua, R.S.; Tilbury, R.S.
1978-09-30
Progress is reported on biomedical studies using cyclotron-produced /sup 18/F, /sup 15/O, /sup 11/C, /sup 13/N, /sup 52/Fe, /sup 38/K, /sup 206/Bi, /sup 73/Se, /sup 53/Co, and /sup 43/K. The following research projects are described: tumor detection and diagnosis; neurological studies; radiopharmaceutical development; /sup 38/K as an indicator of blood flow to the myocardium; dosimetry for internally deposited isotopes in animals and man; cyclotron development; positron tomographic imaging with the TOKIM System; and review of positron emission transaxial tomograph instruments. (HLW)
Tomographic capabilities of the new GEM based SXR diagnostic of WEST
NASA Astrophysics Data System (ADS)
Jardin, A.; Mazon, D.; O'Mullane, M.; Mlynar, J.; Loffelmann, V.; Imrisek, M.; Chernyshova, M.; Czarski, T.; Kasprowicz, G.; Wojenski, A.; Bourdelle, C.; Malard, P.
2016-07-01
The tokamak WEST (Tungsten Environment in Steady-State Tokamak) will start operating by the end of 2016 as a test bed for the ITER divertor components in long pulse operation. In this context, radiative cooling of heavy impurities like tungsten (W) in the Soft X-ray (SXR) range [0.1 keV; 20 keV] is a critical issue for the plasma core performances. Thus reliable tools are required to monitor the local impurity density and avoid W accumulation. The WEST SXR diagnostic will be equipped with two new GEM (Gas Electron Multiplier) based poloidal cameras allowing to perform 2D tomographic reconstructions in tunable energy bands. In this paper tomographic capabilities of the Minimum Fisher Information (MFI) algorithm developed for Tore Supra and upgraded for WEST are investigated, in particular through a set of emissivity phantoms and the standard WEST scenario including reconstruction errors, influence of noise as well as computational time.
Brain activation during human male ejaculation revisited.
Georgiadis, Janniko R; Reinders, A A T Simone; Van der Graaf, Ferdinand H C E; Paans, Anne M J; Kortekaas, Rudie
2007-04-16
In a prior [O]-H2O positron emission tomographic study we reported brain regions involved in human male ejaculation. Here, we used another, more recently acquired data set to evaluate the methodological approach of this previous study, and discovered that part of the reported activation pattern was not related to ejaculation. With a new analysis of these ejaculation data, we now demonstrate ejaculation-related activations in the deep cerebellar nuclei (dentate nucleus), anterior vermis, pons, and ventrolateral thalamus, and, most importantly, ejaculation-related deactivations throughout the prefrontal cortex. This revision offers a new and more accurate insight into the brain regions involved in human male ejaculation.
Lithographed spectrometers for tomographic line mapping of the Epoch of Reionization
NASA Astrophysics Data System (ADS)
O'Brient, R.; Bock, J. J.; Bradford, C. M.; Crites, A.; Duan, R.; Hailey-Dunsheath, S.; Hunacek, J.; LeDuc, R.; Shirokoff, E.; Staniszewski, Z.; Turner, A.; Zemcov, M.
2014-08-01
The Tomographic Ionized carbon Mapping Experiment (TIME) is a multi-phased experiment that will topographically map [CII] emission from the Epoch of Reionization. We are developing lithographed spectrometers that couple to TES bolometers in anticipation of the second generation instrument. Our design intentionally mirrors many features of the parallel SuperSpec project, inductively coupling power from a trunk-line microstrip onto half-wave resonators. The resonators couple to a rat-race hybrids that feeds TES bolometers. Our 25 channel prototype shows spectrally positioned lines roughly matching design with a receiver optical efficiency of 15-20%, a level that is dominated by loss in components outside the spectrometer.
Tomographic imaging of OH laser-induced fluorescence in laminar and turbulent jet flames
NASA Astrophysics Data System (ADS)
Li, Tao; Pareja, Jhon; Fuest, Frederik; Schütte, Manuel; Zhou, Yihui; Dreizler, Andreas; Böhm, Benjamin
2018-01-01
In this paper a new approach for 3D flame structure diagnostics using tomographic laser-induced fluorescence (Tomo-LIF) of the OH radical was evaluated. The approach combined volumetric illumination with a multi-camera detection system of eight views. Single-shot measurements were performed in a methane/air premixed laminar flame and in a non-premixed turbulent methane jet flame. 3D OH fluorescence distributions in the flames were reconstructed using the simultaneous multiplicative algebraic reconstruction technique. The tomographic measurements were compared and validated against results of OH-PLIF in the laminar flame. The effects of the experimental setup of the detection system and the size of the volumetric illumination on the quality of the tomographic reconstructions were evaluated. Results revealed that the Tomo-LIF is suitable for volumetric reconstruction of flame structures with acceptable spatial resolution and uncertainty. It was found that the number of views and their angular orientation have a strong influence on the quality and accuracy of the tomographic reconstruction while the illumination volume thickness influences mainly the spatial resolution.
Dynamic Positron Emission Tomography [PET] in Man Using Small Bismuth Germanate Crystals
DOE R&D Accomplishments Database
Derenzo, S. E.; Budinger, T. F.; Huesman, R. H.; Cahoon, J. L.
1982-04-01
Primary considerations for the design of positron emission tomographs for medical studies in humans are the need for high imaging sensitivity, whole organ coverage, good spatial resolution, high maximum data rates, adequate spatial sampling with minimum mechanical motion, shielding against out of plane activity, pulse height discrimination against scattered photons, and timing discrimination against accidental coincidences. We discuss the choice of detectors, sampling motion, shielding, and electronics to meet these objectives.
Quantification of Methane Source Locations and Emissions in AN Urban Setting
NASA Astrophysics Data System (ADS)
Crosson, E.; Richardson, S.; Tan, S. M.; Whetstone, J.; Bova, T.; Prasad, K. R.; Davis, K. J.; Phillips, N. G.; Turnbull, J. C.; Shepson, P. B.; Cambaliza, M. L.
2011-12-01
The regulation of methane emissions from urban sources such as landfills and waste-water treatment facilities is currently a highly debated topic in the US and in Europe. This interest is fueled, in part, by recent measurements indicating that urban emissions are a significant source of Methane (CH4) and in fact may be substantially higher than current inventory estimates(1). As a result, developing methods for locating and quantifying emissions from urban methane sources is of great interest to industries such as landfill and wastewater treatment facility owners, watchdog groups, and the governmental agencies seeking to evaluate or enforce regulations. In an attempt to identify major methane source locations and emissions in Boston, Indianapolis, and the Bay Area, systematic measurements of CH4 concentrations and meteorology data were made at street level using a vehicle mounted cavity ringdown analyzer. A number of discrete sources were detected at concentration levels in excess of 15 times background levels. Using Gaussian plume models as well as tomographic techniques, methane source locations and emission rates will be presented. In addition, flux chamber measurements of discrete sources such as those found in natural gas leaks will also be presented. (1) Wunch, D., P.O. Wennberg, G.C. Toon, G. Keppel-Aleks, and Y.G. Yavin, Emissions of Greenhouse Gases from a North American Megacity, Geophysical Research Letters, Vol. 36, L15810, doi:10.1029/2009GL)39825, 2009.
Tomographic inversion of satellite photometry
NASA Technical Reports Server (NTRS)
Solomon, S. C.; Hays, P. B.; Abreu, V. J.
1984-01-01
An inversion algorithm capable of reconstructing the volume emission rate of thermospheric airglow features from satellite photometry has been developed. The accuracy and resolution of this technique are investigated using simulated data, and the inversions of several sets of observations taken by the Visible Airglow Experiment are presented.
ERIC Educational Resources Information Center
Damasio, Antonio R., Damasio, Hanna
1992-01-01
Discusses the advances made in understanding the brain structures responsible for language. Presents findings made using magnetic resonance imaging (MRI) and positron emission tomographic (PET) scans to study brain activity. These findings map the structures in the brain that manipulate concepts and those that turn concepts into words. (MCO)
21 CFR 212.1 - What are the meanings of the technical terms used in these regulations?
Code of Federal Regulations, 2014 CFR
2014-04-01
..., numbers, or symbols from which the complete history of the production, processing, packing, holding, and... is used for providing dual photon positron emission tomographic diagnostic images. The definition.... Production means the manufacturing, compounding, processing, packaging, labeling, reprocessing, repacking...
21 CFR 212.1 - What are the meanings of the technical terms used in these regulations?
Code of Federal Regulations, 2012 CFR
2012-04-01
..., numbers, or symbols from which the complete history of the production, processing, packing, holding, and... is used for providing dual photon positron emission tomographic diagnostic images. The definition.... Production means the manufacturing, compounding, processing, packaging, labeling, reprocessing, repacking...
21 CFR 212.1 - What are the meanings of the technical terms used in these regulations?
Code of Federal Regulations, 2013 CFR
2013-04-01
..., numbers, or symbols from which the complete history of the production, processing, packing, holding, and... is used for providing dual photon positron emission tomographic diagnostic images. The definition.... Production means the manufacturing, compounding, processing, packaging, labeling, reprocessing, repacking...
Normal-pressure hydrocephalus and the saga of the treatable dementias
DOE Office of Scientific and Technical Information (OSTI.GOV)
Friedland, R.P.
1989-11-10
A case study of a 74-year-old woman is presented which illustrates the difficulty of understanding dementing illnesses. A diagnosis of normal-pressure hydrocephalus (NPH) was made because of the development of abnormal gait, with urinary incontinence and severe, diffuse, white matter lesions on the MRI scan. Computed tomographic, MRI scans and positron emission tomographic images of glucose use are presented. The treatable dementias are a large, multifaceted group of illnesses, of which NPH is one. The author proposes a new term for this disorder commonly known as NPH because the problem with the term normal-pressure hydrocephalus is that the cerebrospinal fluidmore » pressure is not always normal in the disease.« less
Single-photon tomographic determination of regional cerebral blood flow in epilepsy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bonte, F.J.; Devous, M.D. Sr.; Stokely, E.M.
Using a single-photon emission computed tomographic scanner (SPECT) the authors determined regional cerebral blood flow (rCBF) with inhaled xenon-133, a noninvasive procedure. Studies were performed in 40 normal individuals, and these were compared with rCBF determinations in 51 patients with seizure disorders. Although positive results were obtained in 15 of 16 patients with mass lesions, the group of principal interest comprised 25 patients suffering from ''temporal lobe'' epilepsy. Only one of these had a positive x-ray computed tomogram, but 16 had positive findings on rCBF study. These findings included increased local blood flow in the ictal state and reduced flowmore » interictally.« less
Initial evaluation of discrete orthogonal basis reconstruction of ECT images
DOE Office of Scientific and Technical Information (OSTI.GOV)
Moody, E.B.; Donohue, K.D.
1996-12-31
Discrete orthogonal basis restoration (DOBR) is a linear, non-iterative, and robust method for solving inverse problems for systems characterized by shift-variant transfer functions. This simulation study evaluates the feasibility of using DOBR for reconstructing emission computed tomographic (ECT) images. The imaging system model uses typical SPECT parameters and incorporates the effects of attenuation, spatially-variant PSF, and Poisson noise in the projection process. Sample reconstructions and statistical error analyses for a class of digital phantoms compare the DOBR performance for Hartley and Walsh basis functions. Test results confirm that DOBR with either basis set produces images with good statistical properties. Nomore » problems were encountered with reconstruction instability. The flexibility of the DOBR method and its consistent performance warrants further investigation of DOBR as a means of ECT image reconstruction.« less
Clinical applications with the HIDAC positron camera
NASA Astrophysics Data System (ADS)
Frey, P.; Schaller, G.; Christin, A.; Townsend, D.; Tochon-Danguy, H.; Wensveen, M.; Donath, A.
1988-06-01
A high density avalanche chamber (HIDAC) positron camera has been used for positron emission tomographic (PET) imaging in three different human studies, including patients presenting with: (I) thyroid diseases (124 cases); (II) clinically suspected malignant tumours of the pharynx or larynx (ENT) region (23 cases); and (III) clinically suspected primary malignant and metastatic tumours of the liver (9 cases, 19 PET scans). The positron emitting radiopharmaceuticals used for the three studies were Na 124I (4.2 d half-life) for the thyroid, 55Co-bleomycin (17.5 h half-life) for the ENT-region and 68Ga-colloid (68 min half-life) for the liver. Tomographic imaging was performed: (I) 24 h after oral Na 124I administration to the thyroid patients, (II) 18 h after intraveneous administration of 55Co-bleomycin to the ENT patients and (III) 20 min following the intraveneous injection of 68Ga-colloid to the liver tumour patients. Three different imaging protocols were used with the HIDAC positron camera to perform appropriate tomographic imaging in each patient study. Promising results were obtained in all three studies, particularly in tomographic thyroid imaging, where a significant clinical contribution is made possible for diagnosis and therapy planning by the PET technique. In the other two PET studies encouraging results were obtained for the detection and precise localisation of malignant tumour disease including an estimate of the functional liver volume based on the reticulo-endothelial-system (RES) of the liver, obtained in vivo, and the three-dimensional display of liver PET data using shaded graphics techniques. The clinical significance of the overall results obtained in both the ENT and the liver PET study, however, is still uncertain and the respective role of PET as a new imaging modality in these applications is not yet clearly established. To appreciate the clinical impact made by PET in liver and ENT malignant tumour staging needs further investigation, and more detailed data on a larger number of clinical and experimental PET scans will be necessary for definitive evaluation. Nevertheless, the HIDAC positron camera may be used for clinical PET imaging in well-defined patient cases, particularly in situations where both high spatial resolution is desired in the reconstructed image of the examined pathological condition and at the same time "static" PET imaging may be adequate, as is the case in thyroid-, ENT- and liver tomographic imaging using the HIDAC positron camera.
Templin, Christian; Zweigerdt, Robert; Schwanke, Kristin; Olmer, Ruth; Ghadri, Jelena-Rima; Emmert, Maximilian Y; Müller, Ennio; Küest, Silke M; Cohrs, Susan; Schibli, Roger; Kronen, Peter; Hilbe, Monika; Reinisch, Andreas; Strunk, Dirk; Haverich, Axel; Hoerstrup, Simon; Lüscher, Thomas F; Kaufmann, Philipp A; Landmesser, Ulf; Martin, Ulrich
2012-07-24
Evaluation of novel cellular therapies in large-animal models and patients is currently hampered by the lack of imaging approaches that allow for long-term monitoring of viable transplanted cells. In this study, sodium iodide symporter (NIS) transgene imaging was evaluated as an approach to follow in vivo survival, engraftment, and distribution of human-induced pluripotent stem cell (hiPSC) derivatives in a pig model of myocardial infarction. Transgenic hiPSC lines stably expressing a fluorescent reporter and NIS (NIS(pos)-hiPSCs) were established. Iodide uptake, efflux, and viability of NIS(pos)-hiPSCs were assessed in vitro. Ten (±2) days after induction of myocardial infarction by transient occlusion of the left anterior descending artery, catheter-based intramyocardial injection of NIS(pos)-hiPSCs guided by 3-dimensional NOGA mapping was performed. Dual-isotope single photon emission computed tomographic/computed tomographic imaging was applied with the use of (123)I to follow donor cell survival and distribution and with the use of (99m)TC-tetrofosmin for perfusion imaging. In vitro, iodide uptake in NIS(pos)-hiPSCs was increased 100-fold above that of nontransgenic controls. In vivo, viable NIS(pos)-hiPSCs could be visualized for up to 15 weeks. Immunohistochemistry demonstrated that hiPSC-derived endothelial cells contributed to vascularization. Up to 12 to 15 weeks after transplantation, no teratomas were detected. This study describes for the first time the feasibility of repeated long-term in vivo imaging of viability and tissue distribution of cellular grafts in large animals. Moreover, this is the first report demonstrating vascular differentiation and long-term engraftment of hiPSCs in a large-animal model of myocardial infarction. NIS(pos)-hiPSCs represent a valuable tool to monitor and improve current cellular treatment strategies in clinically relevant animal models.
NASA Astrophysics Data System (ADS)
Olaguer, Eduardo P.; Stutz, Jochen; Erickson, Matthew H.; Hurlock, Stephen C.; Cheung, Ross; Tsai, Catalina; Colosimo, Santo F.; Festa, James; Wijesinghe, Asanga; Neish, Bradley S.
2017-02-01
During the Benzene and other Toxics Exposure (BEE-TEX) study, a remote sensing network based on long path Differential Optical Absorption Spectroscopy (DOAS) was set up in the Manchester neighborhood beside the Ship Channel of Houston, Texas in order to perform Computer Aided Tomography (CAT) scans of hazardous air pollutants. On 18-19 February 2015, the CAT scan network detected large nocturnal plumes of toluene and xylenes most likely associated with railcar loading and unloading operations at Ship Channel petrochemical facilities. The presence of such plumes during railcar operations was confirmed by a mobile laboratory equipped with a Proton Transfer Reaction-Mass Spectrometer (PTR-MS), which measured transient peaks of toluene and C2-benzenes of 50 ppb and 57 ppb respectively around 4 a.m. LST on 19 February 2015. Plume reconstruction and source attribution were performed using the 4D variational data assimilation technique and a 3D micro-scale forward and adjoint air quality model based on both tomographic and PTR-MS data. Inverse model estimates of fugitive emissions associated with railcar transfer emissions ranged from 2.0 to 8.2 kg/hr for toluene and from 2.2 to 3.5 kg/hr for xylenes in the early morning of 19 February 2015.
NASA Astrophysics Data System (ADS)
Craciunescu, Teddy; Peluso, Emmanuele; Murari, Andrea; Gelfusa, Michela; JET Contributors
2018-05-01
The total emission of radiation is a crucial quantity to calculate the power balances and to understand the physics of any Tokamak. Bolometric systems are the main tool to measure this important physical quantity through quite sophisticated tomographic inversion methods. On the Joint European Torus, the coverage of the bolometric diagnostic, due to the availability of basically only two projection angles, is quite limited, rendering the inversion a very ill-posed mathematical problem. A new approach, based on the maximum likelihood, has therefore been developed and implemented to alleviate one of the major weaknesses of traditional tomographic techniques: the difficulty to determine routinely the confidence intervals in the results. The method has been validated by numerical simulations with phantoms to assess the quality of the results and to optimise the configuration of the parameters for the main types of emissivity encountered experimentally. The typical levels of statistical errors, which may significantly influence the quality of the reconstructions, have been identified. The systematic tests with phantoms indicate that the errors in the reconstructions are quite limited and their effect on the total radiated power remains well below 10%. A comparison with other approaches to the inversion and to the regularization has also been performed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nakajima, K.; Bunko, H.; Tada, A.
1984-01-01
Phase analysis has been applied to Wolff-Parkinson-White syndrome (WPW) to detect the site of accessory conduction pathway (ACP); however, there was a limitation to estimate the precise location of ACP by planar phase analysis. In this study, the authors applied phase analysis to gated blood pool tomography. Twelve patients with WPW who underwent epicardial mapping and surgical division of ACP were studied by both of gated emission computed tomography (GECT) and routine gated blood pool study (GBPS). The GBPS was performed with Tc-99m red blood cells in multiple projections; modified left anterior oblique, right anterior oblique and/or left lateral views.more » In GECT, short axial, horizontal and vertical long axial blood pool images were reconstructed. Phase analysis was performed using fundamental frequency of the Fourier transform in both GECT and GBPS images, and abnormal initial contractions on both the planar and tomographic phase analysis were compared with the location of surgically confirmed ACPs. In planar phase analysis, abnormal initial phase was identified in 7 out of 12 (58%) patients, while in tomographic phase analysis, the localization of ACP was predicted in 11 out of 12 (92%) patients. Tomographic phase analysis is superior to planar phase images in 8 out of 12 patients to estimate the location of ACP. Phase analysis by GECT can avoid overlap of blood pool in cardiac chambers and has advantage to identify the propagation of phase three-dimensionally. Tomographic phase analysis is a good adjunctive method for patients with WPW to estimate the site of ACP.« less
J-PET: A New Technology for the Whole-body PET Imaging
NASA Astrophysics Data System (ADS)
Niedźwiecki, S.; Białas, P.; Curceanu, C.; Czerwiński, E.; Dulski, K.; Gajos, A.; Głowacz, B.; Gorgol, M.; Hiesmayr, B. C.; Jasińska, B.; Kapłon, Ł.; Kisielewska-Kamińska, D.; Korcyl, G.; Kowalski, P.; Kozik, T.; Krawczyk, N.; Krzemień, W.; Kubicz, E.; Mohammed, M.; Pawlik-Niedźwiecka, M.; Pałka, M.; Raczyński, L.; Rudy, Z.; Sharma, N. G.; Sharma, S.; Shopa, R. Y.; Silarski, M.; Skurzok, M.; Wieczorek, A.; Wiślicki, W.; Zgardzińska, B.; Zieliński, M.; Moskal, P.
The Jagiellonian Positron Emission Tomograph (J-PET) is the first PET built from plastic scintillators. J-PET prototype consists of 192 detection modules arranged axially in three layers forming a cylindrical diagnostic chamber with the inner diameter of 85 cm and the axial field-of-view of 50 cm. An axial arrangement of long strips of plastic scintillators, their small light attenuation, superior timing properties, and relative ease of the increase of the axial field-of-view opens promising perspectives for the cost effective construction of the whole-body PET scanner, as well as construction of MR and CT compatible PET inserts. Present status of the development of the J-PET tomograph will be presented and discussed.
Kotasidis, F A; Mehranian, A; Zaidi, H
2016-05-07
Kinetic parameter estimation in dynamic PET suffers from reduced accuracy and precision when parametric maps are estimated using kinetic modelling following image reconstruction of the dynamic data. Direct approaches to parameter estimation attempt to directly estimate the kinetic parameters from the measured dynamic data within a unified framework. Such image reconstruction methods have been shown to generate parametric maps of improved precision and accuracy in dynamic PET. However, due to the interleaving between the tomographic and kinetic modelling steps, any tomographic or kinetic modelling errors in certain regions or frames, tend to spatially or temporally propagate. This results in biased kinetic parameters and thus limits the benefits of such direct methods. Kinetic modelling errors originate from the inability to construct a common single kinetic model for the entire field-of-view, and such errors in erroneously modelled regions could spatially propagate. Adaptive models have been used within 4D image reconstruction to mitigate the problem, though they are complex and difficult to optimize. Tomographic errors in dynamic imaging on the other hand, can originate from involuntary patient motion between dynamic frames, as well as from emission/transmission mismatch. Motion correction schemes can be used, however, if residual errors exist or motion correction is not included in the study protocol, errors in the affected dynamic frames could potentially propagate either temporally, to other frames during the kinetic modelling step or spatially, during the tomographic step. In this work, we demonstrate a new strategy to minimize such error propagation in direct 4D image reconstruction, focusing on the tomographic step rather than the kinetic modelling step, by incorporating time-of-flight (TOF) within a direct 4D reconstruction framework. Using ever improving TOF resolutions (580 ps, 440 ps, 300 ps and 160 ps), we demonstrate that direct 4D TOF image reconstruction can substantially prevent kinetic parameter error propagation either from erroneous kinetic modelling, inter-frame motion or emission/transmission mismatch. Furthermore, we demonstrate the benefits of TOF in parameter estimation when conventional post-reconstruction (3D) methods are used and compare the potential improvements to direct 4D methods. Further improvements could possibly be achieved in the future by combining TOF direct 4D image reconstruction with adaptive kinetic models and inter-frame motion correction schemes.
NASA Astrophysics Data System (ADS)
Kotasidis, F. A.; Mehranian, A.; Zaidi, H.
2016-05-01
Kinetic parameter estimation in dynamic PET suffers from reduced accuracy and precision when parametric maps are estimated using kinetic modelling following image reconstruction of the dynamic data. Direct approaches to parameter estimation attempt to directly estimate the kinetic parameters from the measured dynamic data within a unified framework. Such image reconstruction methods have been shown to generate parametric maps of improved precision and accuracy in dynamic PET. However, due to the interleaving between the tomographic and kinetic modelling steps, any tomographic or kinetic modelling errors in certain regions or frames, tend to spatially or temporally propagate. This results in biased kinetic parameters and thus limits the benefits of such direct methods. Kinetic modelling errors originate from the inability to construct a common single kinetic model for the entire field-of-view, and such errors in erroneously modelled regions could spatially propagate. Adaptive models have been used within 4D image reconstruction to mitigate the problem, though they are complex and difficult to optimize. Tomographic errors in dynamic imaging on the other hand, can originate from involuntary patient motion between dynamic frames, as well as from emission/transmission mismatch. Motion correction schemes can be used, however, if residual errors exist or motion correction is not included in the study protocol, errors in the affected dynamic frames could potentially propagate either temporally, to other frames during the kinetic modelling step or spatially, during the tomographic step. In this work, we demonstrate a new strategy to minimize such error propagation in direct 4D image reconstruction, focusing on the tomographic step rather than the kinetic modelling step, by incorporating time-of-flight (TOF) within a direct 4D reconstruction framework. Using ever improving TOF resolutions (580 ps, 440 ps, 300 ps and 160 ps), we demonstrate that direct 4D TOF image reconstruction can substantially prevent kinetic parameter error propagation either from erroneous kinetic modelling, inter-frame motion or emission/transmission mismatch. Furthermore, we demonstrate the benefits of TOF in parameter estimation when conventional post-reconstruction (3D) methods are used and compare the potential improvements to direct 4D methods. Further improvements could possibly be achieved in the future by combining TOF direct 4D image reconstruction with adaptive kinetic models and inter-frame motion correction schemes.
Evaluation of positron emission tomography as a method to visualize subsurface microbial processes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kinsella K.; Schlyer D.; Kinsella, K.
2012-01-18
Positron emission tomography (PET) provides spatiotemporal monitoring in a nondestructive manner and has higher sensitivity and resolution relative to other tomographic methods. Therefore, this technology was evaluated for its application to monitor in situ subsurface bacterial activity. To date, however, it has not been used to monitor or image soil microbial processes. In this study, PET imaging was applied as a 'proof-of-principle' method to assess the feasibility of visualizing a radiotracer labeled subsurface bacterial strain (Rahnella sp. Y9602), previously isolated from uranium contaminated soils and shown to promote uranium phosphate precipitation. Soil columns packed with acid-purified simulated mineral soils weremore » seeded with 2-deoxy-2-[{sup 18}F]fluoro-d-glucose ({sup 18}FDG) labeled Rahnella sp. Y9602. The applicability of [{sup 18}F]fluoride ion as a tracer for measuring hydraulic conductivity and {sup 18}FDG as a tracer to identify subsurface metabolically active bacteria was successful in our soil column studies. Our findings indicate that positron-emitting isotopes can be utilized for studies aimed at elucidating subsurface microbiology and geochemical processes important in contaminant remediation.« less
Single photon emission tomography using 99mTc-HM-PAO in the investigation of dementia.
Neary, D; Snowden, J S; Shields, R A; Burjan, A W; Northen, B; MacDermott, N; Prescott, M C; Testa, H J
1987-01-01
Single photon emission tomographic imaging of the brain using 99mTc HM-PAO was carried out in patients with a clinical diagnosis of Alzheimer's disease, non-Alzheimer frontal-lobe dementia, and progressive supranuclear palsy. Independent assessment of reductions in uptake revealed posterior hemisphere abnormalities in the majority of the Alzheimer group, and selective anterior hemisphere abnormalities in both other groups. The findings were consistent with observed patterns of mental impairment. The imaging technique has potential value in the differential diagnosis of primary cerebral atrophy. Images PMID:3499484
DOE Office of Scientific and Technical Information (OSTI.GOV)
Potchen, E.J.; Harris, G.I.; Gift, D.A. Reinhard, D.K.
Results are reported of the final phase of the study effort generally titled Evaluative Studies in Nuclear Medicine Research. The previous work is reviewed and extended to an assessment providing perspectives on medical applications of positron emission tomographic (PET) systems, their technological context, and the related economic and marketing environment. Methodologies developed and used in earlier phases of the study were continued, but specifically extended to include solicitation of opinion from commercial organizations deemed to be potential developers, manufacturers and marketers of PET systems. Several factors which influence the demand for clinical uses of PET are evaluated and discussed. Themore » recent Federal funding of applied research with PET systems is found to be a necessary and encouraging event toward a determination that PET either is a powerful research tool limited to research, or whether it also presents major clinical utility. A comprehensive, updated bibliography of current literature related to the development, applications and economic considerations of PET technology is appended.« less
Brain Correlates of Stuttering and Syllable Production: Gender Comparison and Replication.
ERIC Educational Resources Information Center
Ingham, Roger J.; Fox, Peter T.; Ingham, Janis C.; Xiong, Jinhu; Zamarripa, Frank; Hardies, L. Jean; Lancaster, Jack L.
2004-01-01
This article reports a gender replication study of the P. T. Fox et a. (2000) performance correlation analysis of neural systems that distinguish between normal and stuttered speech in adult males. Positron-emission tomographic (PET) images of cerebral blood flow (CBF) were correlated with speech behavior scores obtained during PET imaging for 10…
Multiphoton tomography of intratissue tattoo nanoparticles
NASA Astrophysics Data System (ADS)
König, Karsten
2012-02-01
Most of today's intratissue tattoo pigments are unknown nanoparticles. So far, there was no real control of their use due to the absence of regulations. Some of the tattoo pigments contain carcinogenic amines e.g. azo pigment Red 22. Nowadays, the European Union starts to control the administration of tattoo pigments. There is an interest to obtain information on the intratissue distribution, their interaction with living cells and the extracellular matrix, and the mechanisms behind laser tattoo removal. Multiphoton tomographs are novel biosafety and imaging tools that can provide such information non-invasively and without further labeling. When using the spectral FLIM module, spatially-resolved emission spectra, excitation spectra, and fluorescence lifetimes can pr provided. Multiphoton tomographs are used by all major cosmetic comapanies to test the biosafety of sunscreen nanoparticles.
Murder, insanity, and medical expert witnesses.
Ciccone, J R
1992-06-01
Recent advances in the ability to study brain anatomy and function and attempts to link these findings with human behavior have captured the attention of the legal system. This had led to the increasing use of the "neurological defense" to support a plea of not guilty by reason of insanity. This article explores the history of the insanity defense and explores the role of the medical expert witnesses in integrating clinical and laboratory findings, eg, computed tomographic scans, magnetic resonance scans, and single-photon emission computed tomographic scans. Three cases involving murder and brain dysfunction are discussed: the first case involves a subarachnoid hemorrhage resulting in visual perceptual and memory impairment; the second case, a diagnosis of Alzheimer's disease; and the third case, the controverted diagnosis of complex partial seizures in a serial killer.
Three-dimensional Image Reconstruction in J-PET Using Filtered Back-projection Method
NASA Astrophysics Data System (ADS)
Shopa, R. Y.; Klimaszewski, K.; Kowalski, P.; Krzemień, W.; Raczyński, L.; Wiślicki, W.; Białas, P.; Curceanu, C.; Czerwiński, E.; Dulski, K.; Gajos, A.; Głowacz, B.; Gorgol, M.; Hiesmayr, B.; Jasińska, B.; Kisielewska-Kamińska, D.; Korcyl, G.; Kozik, T.; Krawczyk, N.; Kubicz, E.; Mohammed, M.; Pawlik-Niedźwiecka, M.; Niedźwiecki, S.; Pałka, M.; Rudy, Z.; Sharma, N. G.; Sharma, S.; Silarski, M.; Skurzok, M.; Wieczorek, A.; Zgardzińska, B.; Zieliński, M.; Moskal, P.
We present a method and preliminary results of the image reconstruction in the Jagiellonian PET tomograph. Using GATE (Geant4 Application for Tomographic Emission), interactions of the 511 keV photons with a cylindrical detector were generated. Pairs of such photons, flying back-to-back, originate from e+e- annihilations inside a 1-mm spherical source. Spatial and temporal coordinates of hits were smeared using experimental resolutions of the detector. We incorporated the algorithm of the 3D Filtered Back Projection, implemented in the STIR and TomoPy software packages, which differ in approximation methods. Consistent results for the Point Spread Functions of ~5/7,mm and ~9/20, mm were obtained, using STIR, for transverse and longitudinal directions, respectively, with no time of flight information included.
Huang, Chih-Hao; Brunsvold, Michael A
2006-01-01
Maxillary sinusitis may develop from the extension of periodontal disease. In this case, reconstructed three-dimensional images from multidetector spiral computed tomographs were helpful in evaluating periodontal bony defects and their relationship with the maxillary sinus. A 42-year-old woman in good general health presented with a chronic deep periodontal pocket on the palatal and interproximal aspects of tooth #14. Probing depths of the tooth ranged from 2 to 9 mm, and it exhibited a Class 1 mobility. Radiographs revealed a close relationship between the root apex and the maxillary sinus. The patient's periodontal diagnosis was localized severe chronic periodontitis. Treatment of the tooth consisted of cause-related therapy, surgical exploration, and bone grafting. A very deep circumferential bony defect at the palatal root of tooth #14 was noted during surgery. After the operation, the wound healed without incidence, but 10 days later, a maxillary sinusitis and periapical abscess developed. To control the infection, an evaluation of sinus and alveolus using computed tomographs was performed, systemic antibiotics were prescribed, and endodontic treatment was initiated. Two weeks after surgical treatment, the infection was relieved with the help of antibiotics and endodontic treatment. Bilateral bony communications between the maxillary sinus and periodontal bony defect of maxillary first molars were shown on three-dimensional computed tomographs. The digitally reconstructed images added valuable information for evaluating the periodontal defects. Three-dimensional images from spiral computed tomographs (CT) aided in evaluating and treating the close relationship between maxillary sinus disease and adjacent periodontal defects.
Clark, Paige B; Soo, Victoria; Kraas, Jonathan; Shen, Perry; Levine, Edward A
2006-03-01
Evaluation of newly diagnosed patients with melanoma for metastasis is requisite to treatment planning. The reported diagnostic yield of whole-body conventional radiological imaging in initial staging of patients with melanoma is low. However, the diagnostic yield of positron emission tomography (PET) for distant metastases is unclear. There is no utility of PET as part of a routine metastatic survey in patients with T2 to T4 melanoma. Retrospective review of a cohort study between December 1998 and July 2004. University hospital tertiary care center. There were 64 patients with T2 to T4 melanomas who underwent PET for detection of occult metastases at our institution. All patients underwent surgical excision of the primary lesion and sentinel lymph node dissection. Data included were pathologic findings of the primary lesion and sentinel lymph nodes, laboratory data, and radiological reports. None of the patients had clinically suspected regional or distant metastases prior to PET. The diagnostic yield of PET was evaluated through retrospective analysis. Positive scans were then correlated for accuracy with follow-up imaging, biopsy, and clinical information when available. Positron emission tomography did not reveal occult distant metastases in any of the patients. Positron emission tomographic scans showed no abnormalities in 94% of these patients. In 2 patients (3%), false-positive findings were reported on PET (muscular activity and intranodal melanocytic nevocellular inclusion). Further, PET was not useful in predicting regional lymph node metastases. Nineteen of 64 patients had positive sentinel lymph nodes, and only 2 (11%) were identified on PET. Overall, PET did not change clinical management in any of the patients. This study suggests no utility for PET in the detection of occult metastases in patients at initial diagnosis of melanoma. Omission of PET imaging from preoperative evaluations for patients with melanoma is recommended.
A flexible, small positron emission tomography prototype for resource-limited laboratories
NASA Astrophysics Data System (ADS)
Miranda-Menchaca, A.; Martínez-Dávalos, A.; Murrieta-Rodríguez, T.; Alva-Sánchez, H.; Rodríguez-Villafuerte, M.
2015-05-01
Modern small-animal PET scanners typically consist of a large number of detectors along with complex electronics to provide tomographic images for research in the preclinical sciences that use animal models. These systems can be expensive, especially for resource-limited educational and academic institutions in developing countries. In this work we show that a small-animal PET scanner can be built with a relatively reduced budget while, at the same time, achieving relatively high performance. The prototype consists of four detector modules each composed of LYSO pixelated crystal arrays (individual crystal elements of dimensions 1 × 1 × 10 mm3) coupled to position-sensitive photomultiplier tubes. Tomographic images are obtained by rotating the subject to complete enough projections for image reconstruction. Image quality was evaluated for different reconstruction algorithms including filtered back-projection and iterative reconstruction with maximum likelihood-expectation maximization and maximum a posteriori methods. The system matrix was computed both with geometric considerations and by Monte Carlo simulations. Prior to image reconstruction, Fourier data rebinning was used to increase the number of lines of response used. The system was evaluated for energy resolution at 511 keV (best 18.2%), system sensitivity (0.24%), spatial resolution (best 0.87 mm), scatter fraction (4.8%) and noise equivalent count-rate. The system can be scaled-up to include up to 8 detector modules, increasing detection efficiency, and its price may be reduced as newer solid state detectors become available replacing the traditional photomultiplier tubes. Prototypes like this may prove to be very valuable for educational, training, preclinical and other biological research purposes.
Regional brain hematocrit in stroke by single photon emission computed tomography imaging
DOE Office of Scientific and Technical Information (OSTI.GOV)
Loutfi, I.; Frackowiak, R.S.; Myers, M.J.
1987-01-01
Nineteen studies on 18 subjects were performed by single photon emission computed tomography (SPECT) of the head after the successive intravenous administration of a plasma label (/sup 99m/Tc-human serum albumin (HSA)) and /sup 99m/Tc-labeled autologous red blood cells (RBC). Two sets of cerebral tomographic sections were generated: for cerebral /sup 99m/Tc-HSA alone and for combined /sup 99m/Tc-HSA and /sup 99m/Tc-RBC. By relating counts in regions of interest from the cerebral tomograms to counts from blood samples obtained during each tomographic acquisition, regional cerebral haematocrit (Hct) was calculated by the application of a simple formula. Results show 1) lower cerebral Hctmore » than venous Hct (ratio of HCT brain/Hct venous 0.65-0.90) in all subjects, and 2) comparison between right and left hemisphere Hct in 3/3 normal subjects, 6/6 patients with transient ischaemic attacks and 3/8 patients with stroke showed no significant difference. However, in 3/8 patients with stroke (most recent strokes) significant differences were found, the higher Hct value corresponding to the affected side.« less
Optical coherence tomography using images of hair structure and dyes penetrating into the hair.
Tsugita, Tetsuya; Iwai, Toshiaki
2014-11-01
Hair dyes are commonly evaluated by the appearance of the hair after dyeing. However, this approach cannot simultaneously assess how deep the dye has penetrated into hair. For simultaneous assessment of the appearance and the interior of hair, we developed a visible-range red, green, and blue (RGB) (three primary colors)-optical coherence tomography (OCT) using an RGB LED light source. We then evaluated a phantom model based on the assumption that the sample's absorbability in the vertical direction affects the tomographic imaging. Consistent with theory, our device showed higher resolution than conventional OCT with far-red light. In the experiment on the phantom model, we confirmed that the tomographic imaging is affected by absorbability unique to the sample. Furthermore, we verified that permeability can be estimated from this tomographic image. We also identified for the first time the relationship between penetration of the dye into hair and characteristics of wavelength by tomographic imaging of dyed hair. We successfully simultaneously assessed the appearance of dyed hair and inward penetration of the dye without preparing hair sections. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
NASA Astrophysics Data System (ADS)
Moskal, P.; Alfs, D.; Bednarski, T.; Białas, P.; Curceanu, C.; Czerwiński, E.; Dulski, K.; Gajos, A.; Głowacz, B.; Gupta-Sharma, N.; Gorgol, M.; Hiesmayr, B. C.; Jasińska, B.; Kamińska, D.; Khreptak, O.; Korcyl, G.; Kowalski, P.; Krzemień, W.; Krawczyk, N.; Kubicz, E.; Mohammed, M.; Niedźwiecki, Sz.; Pawlik-Niedńwiecka, M.; Raczyński, L.; Rudy, Z.; Silarski, M.; Smyrski, J.; Wieczorek, A.; Wiślicki, W.; Zgardzińska, B.; Zieliński, M.
2016-11-01
Discrete symmetries such as parity (P), charge-conjugation (C) and time reversal (T) are of fundamental importance in physics and cosmology. Breaking of charge conjugation symmetry (C) and its combination with parity (CP) constitute necessary conditions for the existence of the asymmetry between matter and antimatter in the observed Universe. The presently known sources of discrete symmetries violations can account for only a tiny fraction of the excess of matter over antimatter. So far CP and T symmetries violations were observed only for systems involving quarks and they were never reported for the purely leptonic objects. In this article we describe briefly an experimental proposal for the test of discrete symmetries in the decays of positronium atom which is made exclusively of leptons. The experiments are conducted by means of the Jagiellonian Positron Emission Tomograph (J-PET) which is constructed from strips of plastic scintillators enabling registration of photons from the positronium annihilation. J-PET tomograph together with the positronium target system enable to measure expectation values for the discrete symmetries odd operators constructed from (i) spin vector of the ortho-positronium atom, (ii) momentum vectors of photons originating from the decay of positronium, and (iii) linear polarization direction of annihilation photons. Linearly polarized positronium will be produced in the highly porous aerogel or polymer targets, exploiting longitudinally polarized positrons emitted by the sodium 22Na isotope. Information about the polarization vector of orthopositronium will be available on the event by event basis and will be reconstructed from the known position of the positron source and the reconstructed position of the orthopositronium annihilation. In 2016 the first tests and calibration runs are planned, and the data collection with high statistics will commence in the year 2017.
Nishimura, T; Uehara, T; Shimonagata, T; Nagata, S; Haze, K
1994-01-01
This study was undertaken to evaluate the relationships, between myocardial perfusion and metabolism. Simultaneous beta-methyl-p(123I)iodophenylpentadecanoic acid (123I-BMIPP) and thallium 201 myocardial single-photon emission computed tomography (SPECT) were performed in 25 patients with myocardial infarction (group A) and 16 patients with hypertrophic cardiomyopathy (group B). The severity scores of 123I-BMIPP and 201Tl myocardial SPECT images were evaluated semiquantitatively by segmental analysis. In Group A, dissociations between thallium- and 123I-BMIPP-imaged defects were frequently observed in patients with successful reperfusion compared with those with no reperfusion and those with reinfarction. In four patients with successful reperfusion, repeated 123I-BMIPP and 201Tl myocardial SPECT showed gradual improvement of the 123I-BMIPP severity score compared with the thallium severity score. In group B, dissociations between thallium- and 123I-BMIPP-imaged defects were also demonstrated in hypertrophic myocardium. In addition, nonhypertrophic myocardium also had decreased 123I-BMIPP uptake. In groups A and B, 123I-BMIPP severity scores correlated well with left ventricular function compared with thallium severity scores. These findings indicate that 123I-BMIPP is a suitable agent for the assessment of functional integrity, because left ventricular wall motion is energy dependent and 123I-BMIPP may reflect an aspect of myocardial energy production. This agent may be useful for the early detection and patient management of various heart diseases as an alternative to positron emission tomographic study.
HFSB-seeding for large-scale tomographic PIV in wind tunnels
NASA Astrophysics Data System (ADS)
Caridi, Giuseppe Carlo Alp; Ragni, Daniele; Sciacchitano, Andrea; Scarano, Fulvio
2016-12-01
A new system for large-scale tomographic particle image velocimetry in low-speed wind tunnels is presented. The system relies upon the use of sub-millimetre helium-filled soap bubbles as flow tracers, which scatter light with intensity several orders of magnitude higher than micron-sized droplets. With respect to a single bubble generator, the system increases the rate of bubbles emission by means of transient accumulation and rapid release. The governing parameters of the system are identified and discussed, namely the bubbles production rate, the accumulation and release times, the size of the bubble injector and its location with respect to the wind tunnel contraction. The relations between the above parameters, the resulting spatial concentration of tracers and measurement of dynamic spatial range are obtained and discussed. Large-scale experiments are carried out in a large low-speed wind tunnel with 2.85 × 2.85 m2 test section, where a vertical axis wind turbine of 1 m diameter is operated. Time-resolved tomographic PIV measurements are taken over a measurement volume of 40 × 20 × 15 cm3, allowing the quantitative analysis of the tip-vortex structure and dynamical evolution.
Siontis, George CM; Mavridis, Dimitris; Greenwood, John P; Coles, Bernadette; Nikolakopoulou, Adriani; Jüni, Peter; Salanti, Georgia
2018-01-01
Abstract Objective To evaluate differences in downstream testing, coronary revascularisation, and clinical outcomes following non-invasive diagnostic modalities used to detect coronary artery disease. Design Systematic review and network meta-analysis. Data sources Medline, Medline in process, Embase, Cochrane Library for clinical trials, PubMed, Web of Science, SCOPUS, WHO International Clinical Trials Registry Platform, and Clinicaltrials.gov. Eligibility criteria for selecting studies Diagnostic randomised controlled trials comparing non-invasive diagnostic modalities in patients presenting with symptoms suggestive of low risk acute coronary syndrome or stable coronary artery disease. Data synthesis A random effects network meta-analysis synthesised available evidence from trials evaluating the effect of non-invasive diagnostic modalities on downstream testing and patient oriented outcomes in patients with suspected coronary artery disease. Modalities included exercise electrocardiograms, stress echocardiography, single photon emission computed tomography-myocardial perfusion imaging, real time myocardial contrast echocardiography, coronary computed tomographic angiography, and cardiovascular magnetic resonance. Unpublished outcome data were obtained from 11 trials. Results 18 trials of patients with low risk acute coronary syndrome (n=11 329) and 12 trials of those with suspected stable coronary artery disease (n=22 062) were included. Among patients with low risk acute coronary syndrome, stress echocardiography, cardiovascular magnetic resonance, and exercise electrocardiograms resulted in fewer invasive referrals for coronary angiography than coronary computed tomographic angiography (odds ratio 0.28 (95% confidence interval 0.14 to 0.57), 0.32 (0.15 to 0.71), and 0.53 (0.28 to 1.00), respectively). There was no effect on the subsequent risk of myocardial infarction, but estimates were imprecise. Heterogeneity and inconsistency were low. In patients with suspected stable coronary artery disease, an initial diagnostic strategy of stress echocardiography or single photon emission computed tomography-myocardial perfusion imaging resulted in fewer downstream tests than coronary computed tomographic angiography (0.24 (0.08 to 0.74) and 0.57 (0.37 to 0.87), respectively). However, exercise electrocardiograms yielded the highest downstream testing rate. Estimates for death and myocardial infarction were imprecise without clear discrimination between strategies. Conclusions For patients with low risk acute coronary syndrome, an initial diagnostic strategy of stress echocardiography or cardiovascular magnetic resonance is associated with fewer referrals for invasive coronary angiography and revascularisation procedures than non-invasive anatomical testing, without apparent impact on the future risk of myocardial infarction. For suspected stable coronary artery disease, there was no clear discrimination between diagnostic strategies regarding the subsequent need for invasive coronary angiography, and differences in the risk of myocardial infarction cannot be ruled out. Systematic review registration PROSPERO registry no CRD42016049442. PMID:29467161
NASA Astrophysics Data System (ADS)
Flynn, Brendan P.; D'Souza, Alisha V.; Kanick, Stephen C.; Maytin, Edward; Hasan, Tayyaba; Pogue, Brian W.
2013-03-01
Aminolevulinic acid (ALA)-induced Protoporphyrin IX (PpIX)-based photodynamic therapy (PDT) is an effective treatment for skin cancers including basal cell carcinoma (BCC). Topically applied ALA promotes PpIX production preferentially in tumors, and many strategies have been developed to increase PpIX distribution and PDT treatment efficacy at depths > 1mm is not fully understood. While surface imaging techniques provide useful diagnosis, dosimetry, and efficacy information for superficial tumors, these methods cannot interrogate deeper tumors to provide in situ insight into spatial PpIX distributions. We have developed an ultrasound-guided, white-light-informed, tomographics spectroscopy system for the spatial measurement of subsurface PpIX. Detailed imaging system specifications, methodology, and optical-phantom-based characterization will be presented separately. Here we evaluate preliminary in vivo results using both full tomographic reconstruction and by plotting individual tomographic source-detector pair data against US images.
NASA Astrophysics Data System (ADS)
Staton, Robert J.
Of the various types of imaging modalities used in pediatric radiology, fluoroscopy and computed tomography (CT) have the highest associated radiation dose. While these examinations are commonly used for pediatric patients, little data exists on the magnitude of the organ and effective dose values for these procedures. Calculation of these dose values is necessary because of children's increased sensitivity to radiation and their long life expectancy for which to express radiation's latent effects. In this study, a newborn tomographic phantom has been implemented in a radiation transport code to evaluate organ and effective doses for newborn patients in commonly performed fluoroscopy and CT examinations. Organ doses were evaluated for voiding cystourethrogram (VCUG) fluoroscopy studies of infant patients. Time-sequence analysis was performed for videotaped VCUG studies of five different patients. Organ dose values were then estimated for each patient through Monte Carlo (MC) simulations. The effective dose values of the VCUG examination for five patients ranged from 0.6 mSv to 3.2 mSv, with a mean of 1.8 +/- 0.9 mSv. Organ doses were also assessed for infant upper gastrointestinal (UGI) fluoroscopy exams. The effective dose values of the UGI examinations for five patients ranged from 1.05 mSv to 5.92 mSv, with a mean of 2.90 +/- 1.97 mSv. MC simulations of helical multislice CT (MSCT) exams were also completed using, the newborn tomographic phantom and a stylized newborn phantom. The helical path of the source, beam shaping filter, beam profile, patient table, were all included in the MC simulations of the helical MSCT scanner. Organ doses and effective doses and their dependence on scan parameters were evaluated for newborn patients. For all CT scans, the effective dose was found to range approximately 1-13 mSv, with the largest values occurring for CAP scans. Tube current modulation strategies to reduce patient dose were also evaluated for newborn patients. Overall, utilization of the newborn tomographic phantom in MC simulations has shown the need for and usefulness of pediatric tomographic phantoms. The newborn tomographic model has shown more versatility and realistic anatomical modeling when compared to the existing stylized newborn phantom. This work has provided important organ dose data for infant patients in common examinations in pediatric radiology.
Scarmeas, Nikolaos; Zarahn, Eric; Anderson, Karen E.; Honig, Lawrence S.; Park, Aileen; Hilton, John; Flynn, Joseph; Sackeim, Harold A.; Stern, Yaakov
2011-01-01
Background Cognitive reserve (CR) is the ability of an individual to cope with advancing brain pathological abnormalities so that he or she remains free of symptoms. Epidemiological data and evidence from positron emission tomography suggest that it may be mediated through education or IQ. Objective To investigate CR-mediated differential brain activation in Alzheimer disease (AD) subjects compared with healthy elderly persons. Participants Using radioactive water positron emission tomography, we scanned 12 AD patients and 17 healthy elderly persons while performing a serial recognition memory task for nonverbalizable shapes under 2 conditions: low demand, in which one shape was presented in each study trial, and titrated demand, in which the study list length was adjusted so that each subject recognized shapes at approximately 75% accuracy. Positron emission tomographic scan acquisition included the encoding and recognition phases. A CR factor score that summarized years of education, National Adult Reading Test estimated IQ, and Wechsler Adult Intelligence Scale–Revised vocabulary subtest score (explaining 71% of the total variance) was used as an index of CR. Voxel-wise, multiple regression analyses were performed with the “activation” difference (titrated demand–low demand) as the dependent variables and the CR factor score as the independent one. Brain regions where regression slopes differed between the 2 groups were identified. Results The slopes were significantly more positive for the AD patients in the left precentral gyrus and in the left hippocampus and significantly more negative in the right fusiform, right middle occipital, left superior occipital, and left middle temporal gyri. Conclusion Brain regions where systematic relationships (slopes) between subjects’ education-IQ and brain activation differ as a function of disease status may mediate the differential ability to cope with (ie, delay or modify) clinical manifestations of AD. PMID:14732623
Right ventricular sarcoidosis: is it time for updated diagnostic criteria?
Vakil, Kairav; Minami, Elina; Fishbein, Daniel P
2014-04-01
A 55-year-old woman with a history of complete heart block, atrial flutter, and progressive right ventricular failure was referred to our tertiary care center to be evaluated for cardiac transplantation. The patient's clinical course included worsening right ventricular dysfunction for 3 years before the current evaluation. Our clinical findings raised concerns about arrhythmogenic right ventricular cardiomyopathy. Noninvasive imaging, including a positron emission tomographic scan, did not reveal obvious myocardial pathologic conditions. Given the end-stage nature of the patient's right ventricular failure and her dependence on inotropic agents, she underwent urgent listing and subsequent heart transplantation. Pathologic examination of the explanted heart revealed isolated right ventricular sarcoidosis with replacement fibrosis. Biopsy samples of the cardiac allograft 6 months after transplantation showed no recurrence of sarcoidosis. This atypical presentation of isolated cardiac sarcoidosis posed a considerable diagnostic challenge. In addition to discussing the patient's case, we review the relevant medical literature and discuss the need for updated differential diagnostic criteria for end-stage right ventricular failure that mimics arrhythmogenic right ventricular cardiomyopathy.
Design and evaluation of radiotracers for determination of regional cerebral blood flow with PET
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lambrecht, R.M.; Duncan, C.C.; Shiue, C.Y.
The tracer kinetics of 4-Fluoro(/sup 18/F)-, 4-Bromo(/sup 82/Br)- and 4-Iodo(/sup 125/I)-antipyrine and /sup 15/O-water were compared in a cat or baboon animal model. First-pass cerebral extraction and clearance with alterations in PaCO/sub 2/ were measured for whole brain. The Renkin/Crone model was used to evaluate brain capillary permeability-surface area product for 4-/sup 18/FAP in cats. Positron-emission-tomographic measurements required development of an instrument and technique for control of the arterial concentration of the radiotracer as a ramp function, so that tracer concentration changes due to radioactive decay or altered physiological processes could be accurately described with PET. Pharmacokinetic and tissue-distribution studiesmore » in cats were used to determine dosimetry for 4-/sup 18/FAP. 4-Bromoantipyrine labeled with /sup 78/Br (t = 6.5 m) is suggested as a tracer for determination of rCBF with PET.« less
Schmidt, Sergio L; Schmidt, Juliana J; Tolentino, Julio C; Ferreira, Carlos G; de Almeida, Sergio A; Alvarenga, Regina P; Simoes, Eunice N; Schmidt, Guilherme J; Canedo, Nathalie H S; Chimelli, Leila
2016-07-20
Limbic encephalitis was originally described as a rare clinical neuropathological entity involving seizures and neuropsychological disturbances. In this report, we describe cerebral patterns visualized by positron emission tomography in a patient with limbic encephalitis and cholangiocarcinoma. To our knowledge, there is no other description in the literature of cerebral positron emission tomography findings in the setting of limbic encephalitis and subsequent diagnosis of cholangiocarcinoma. We describe a case of a 77-year-old Caucasian man who exhibited persistent cognitive changes 2 years before his death. A cerebral scan obtained at that time by 2-deoxy-2-[fluorine-18]fluoro- D -glucose integrated with computed tomography-positron emission tomography showed low radiotracer uptake in the frontal and temporal lobes. Cerebrospinal fluid analysis indicated the presence of voltage-gated potassium channel antibodies. Three months before the patient's death, a lymph node biopsy indicated a cholangiocarcinoma, and a new cerebral scan obtained by 2-deoxy-2-[fluorine-18]fluoro-D-glucose integrated with computed tomography-positron emission tomography showed an increment in the severity of metabolic deficit in the frontal and parietal lobes, as well as hypometabolism involving the temporal lobes. Two months before the patient's death, cerebral metastases were detected on a contrast-enhanced computed tomographic scan. Postmortem examination revealed a cholangiocarcinoma with multiple metastases including the lungs and lymph nodes. The patient's brain weighed 1300 g, and mild cortical atrophy, ex vacuo dilation of the ventricles, and mild focal thickening of the cerebellar leptomeninges, which were infiltrated by neoplastic epithelial cells, were observed. These findings support the need for continued vigilance in malignancy surveillance in patients with limbic encephalitis and early cerebral positron emission tomographic scan abnormalities. The difficulty in early diagnosis of small tumors, such as a cholangiocarcinoma, is discussed in the context of the clinical utility of early cerebral hypometabolism detected by 2-deoxy-2-[fluorine-18]fluoro-D-glucose integrated with computed tomography-positron emission tomography in patients with rapidly progressive dementia.
In vivo evaluation of (64)Cu-labeled magnetic nanoparticles as a dual-modality PET/MR imaging agent.
Glaus, Charles; Rossin, Raffaella; Welch, Michael J; Bao, Gang
2010-04-21
A novel nanoparticle-based dual-modality positron emission tomograph/magnetic resonance imaging (PET/MRI) contrast agent was developed. The probe consisted of a superparamagnetic iron oxide (SPIO) core coated with PEGylated phospholipids. The chelator 1,4,7,10-tetraazacyclo-dodecane-1,4,7,10-tetraacetic acid (DOTA) was conjugated to PEG termini to allow labeling with positron-emitting (64)Cu. Radiolabeling with (64)Cu at high yield and high purity was readily achieved. The (64)Cu-SPIO probes produced strong MR and PET signals and were stable in mouse serum for 24 h at 37 degrees C. Biodistribution and in vivo PET/CT imaging studies of the probes showed a circulation half-life of 143 min and high initial blood retention with moderate liver uptake, making them an attractive contrast agent for disease studies.
NASA Astrophysics Data System (ADS)
Munoz Burgos, J. M.; Brooks, N. H.; Fenstermacher, M. E.; Meyer, W. H.; Unterberg, E. A.; Schmitz, O.; Loch, S. D.; Balance, C. P.
2011-10-01
We apply new atomic modeling techniques to helium and deuterium for diagnostics in the divertor and scrape-off layer regions. Analysis of tomographically inverted images is useful for validating detachment prediction models and power balances in the divertor. We apply tomographic image inversion from fast tangential cameras of helium and Dα emission at the divertor in order to obtain 2D profiles of Te, Ne, and ND (neutral ion density profiles). The accuracy of the atomic models for He I will be cross-checked against Thomson scattering measurements of Te and Ne. This work summarizes several current developments and applications of atomic modeling into diagnostic at the DIII-D tokamak. Supported in part by the US DOE under DE-AC05-06OR23100, DE-FC02-04ER54698, DE-AC52-07NA27344, and DE-AC05-00OR22725.
NASA Technical Reports Server (NTRS)
Ter-Pogossian, M. M.; Hoffman, E. J.; Weiss, E. S.; Coleman, R. E.; Phelps, M. E.; Welch, M. J.; Sobel, B. E.
1975-01-01
A positron emission transverse tomograph device was developed which provides transaxial sectional images of the distribution of positron-emitting radionuclides in the heart. The images provide a quantitative three-dimensional map of the distribution of activity unencumbered by the superimposition of activity originating from regions overlying and underlying the plane of interest. PETT is used primarily with the cyclotron-produced radionuclides oxygen-15, nitrogen-13 and carbon-11. Because of the participation of these atoms in metabolism, they can be used to label metabolic substrates and intermediary molecules incorporated in myocardial metabolism.
Quantitative evaluation of the memory bias effect in ROC studies with PET/CT
NASA Astrophysics Data System (ADS)
Kallergi, Maria; Pianou, Nicoletta; Georgakopoulos, Alexandros; Kafiri, Georgia; Pavlou, Spiros; Chatziioannou, Sofia
2012-02-01
PURPOSE. The purpose of the study was to evaluate the memory bias effect in ROC experiments with tomographic data and, specifically, in the evaluation of two different PET/CT protocols for the detection and diagnosis of recurrent thyroid cancer. MATERIALS AND METHODS. Two readers participated in an ROC experiment that evaluated tomographic images from 43 patients followed up for thyroid cancer recurrence. Readers evaluated first whole body PET/CT scans of the patients and then a combination of whole body and high-resolution head and neck scans of the same patients. The second set was read twice. Once within 48 hours of the first set and the second time at least a month later. The detection and diagnostic performances of the readers in the three reading sessions were assessed with the DBMMRMC and LABMRMC software using the area under the ROC curve as a performance index. Performances were also evaluated by comparing the number and the size of the detected abnormal foci among the three readings. RESULTS. There was no performance difference between first and second treatments. There were statistically significant differences between first and third, and second and third treatments showing that memory can seriously affect the outcome of ROC studies. CONCLUSION. Despite the fact that tomographic data involve numerous image slices per patient, the memory bias effect is present and substantial and should be carefully eliminated from analogous ROC experiments.
Optimization of tomographic reconstruction workflows on geographically distributed resources
Bicer, Tekin; Gursoy, Doga; Kettimuthu, Rajkumar; ...
2016-01-01
New technological advancements in synchrotron light sources enable data acquisitions at unprecedented levels. This emergent trend affects not only the size of the generated data but also the need for larger computational resources. Although beamline scientists and users have access to local computational resources, these are typically limited and can result in extended execution times. Applications that are based on iterative processing as in tomographic reconstruction methods require high-performance compute clusters for timely analysis of data. Here, time-sensitive analysis and processing of Advanced Photon Source data on geographically distributed resources are focused on. Two main challenges are considered: (i) modelingmore » of the performance of tomographic reconstruction workflows and (ii) transparent execution of these workflows on distributed resources. For the former, three main stages are considered: (i) data transfer between storage and computational resources, (i) wait/queue time of reconstruction jobs at compute resources, and (iii) computation of reconstruction tasks. These performance models allow evaluation and estimation of the execution time of any given iterative tomographic reconstruction workflow that runs on geographically distributed resources. For the latter challenge, a workflow management system is built, which can automate the execution of workflows and minimize the user interaction with the underlying infrastructure. The system utilizes Globus to perform secure and efficient data transfer operations. The proposed models and the workflow management system are evaluated by using three high-performance computing and two storage resources, all of which are geographically distributed. Workflows were created with different computational requirements using two compute-intensive tomographic reconstruction algorithms. Experimental evaluation shows that the proposed models and system can be used for selecting the optimum resources, which in turn can provide up to 3.13× speedup (on experimented resources). Furthermore, the error rates of the models range between 2.1 and 23.3% (considering workflow execution times), where the accuracy of the model estimations increases with higher computational demands in reconstruction tasks.« less
Optimization of tomographic reconstruction workflows on geographically distributed resources
Bicer, Tekin; Gürsoy, Doǧa; Kettimuthu, Rajkumar; De Carlo, Francesco; Foster, Ian T.
2016-01-01
New technological advancements in synchrotron light sources enable data acquisitions at unprecedented levels. This emergent trend affects not only the size of the generated data but also the need for larger computational resources. Although beamline scientists and users have access to local computational resources, these are typically limited and can result in extended execution times. Applications that are based on iterative processing as in tomographic reconstruction methods require high-performance compute clusters for timely analysis of data. Here, time-sensitive analysis and processing of Advanced Photon Source data on geographically distributed resources are focused on. Two main challenges are considered: (i) modeling of the performance of tomographic reconstruction workflows and (ii) transparent execution of these workflows on distributed resources. For the former, three main stages are considered: (i) data transfer between storage and computational resources, (i) wait/queue time of reconstruction jobs at compute resources, and (iii) computation of reconstruction tasks. These performance models allow evaluation and estimation of the execution time of any given iterative tomographic reconstruction workflow that runs on geographically distributed resources. For the latter challenge, a workflow management system is built, which can automate the execution of workflows and minimize the user interaction with the underlying infrastructure. The system utilizes Globus to perform secure and efficient data transfer operations. The proposed models and the workflow management system are evaluated by using three high-performance computing and two storage resources, all of which are geographically distributed. Workflows were created with different computational requirements using two compute-intensive tomographic reconstruction algorithms. Experimental evaluation shows that the proposed models and system can be used for selecting the optimum resources, which in turn can provide up to 3.13× speedup (on experimented resources). Moreover, the error rates of the models range between 2.1 and 23.3% (considering workflow execution times), where the accuracy of the model estimations increases with higher computational demands in reconstruction tasks. PMID:27359149
Optimization of tomographic reconstruction workflows on geographically distributed resources
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bicer, Tekin; Gursoy, Doga; Kettimuthu, Rajkumar
New technological advancements in synchrotron light sources enable data acquisitions at unprecedented levels. This emergent trend affects not only the size of the generated data but also the need for larger computational resources. Although beamline scientists and users have access to local computational resources, these are typically limited and can result in extended execution times. Applications that are based on iterative processing as in tomographic reconstruction methods require high-performance compute clusters for timely analysis of data. Here, time-sensitive analysis and processing of Advanced Photon Source data on geographically distributed resources are focused on. Two main challenges are considered: (i) modelingmore » of the performance of tomographic reconstruction workflows and (ii) transparent execution of these workflows on distributed resources. For the former, three main stages are considered: (i) data transfer between storage and computational resources, (i) wait/queue time of reconstruction jobs at compute resources, and (iii) computation of reconstruction tasks. These performance models allow evaluation and estimation of the execution time of any given iterative tomographic reconstruction workflow that runs on geographically distributed resources. For the latter challenge, a workflow management system is built, which can automate the execution of workflows and minimize the user interaction with the underlying infrastructure. The system utilizes Globus to perform secure and efficient data transfer operations. The proposed models and the workflow management system are evaluated by using three high-performance computing and two storage resources, all of which are geographically distributed. Workflows were created with different computational requirements using two compute-intensive tomographic reconstruction algorithms. Experimental evaluation shows that the proposed models and system can be used for selecting the optimum resources, which in turn can provide up to 3.13× speedup (on experimented resources). Furthermore, the error rates of the models range between 2.1 and 23.3% (considering workflow execution times), where the accuracy of the model estimations increases with higher computational demands in reconstruction tasks.« less
Min, James K; Shaw, Leslee J; Berman, Daniel S; Gilmore, Amanda; Kang, Ning
2008-09-15
Multidetector coronary computed tomographic angiography (CCTA) demonstrates high accuracy for the detection and exclusion of coronary artery disease (CAD) and predicts adverse prognosis. To date, opportunity costs relating the clinical and economic outcomes of CCTA compared with other methods of diagnosing CAD, such as myocardial perfusion single-photon emission computed tomography (SPECT), remain unknown. An observational, multicenter, patient-level analysis of patients without known CAD who underwent CCTA or SPECT was performed. Patients who underwent CCTA (n = 1,938) were matched to those who underwent SPECT (n = 7,752) on 8 demographic and clinical characteristics and 2 summary measures of cardiac medications and co-morbidities and were evaluated for 9-month expenditures and clinical outcomes. Adjusted total health care and CAD expenditures were 27% (p <0.001) and 33% (p <0.001) lower, respectively, for patients who underwent CCTA compared with those who underwent SPECT, by an average of $467 (95% confidence interval $99 to $984) for CAD expenditures per patient. Despite lower total health care expenditures for CCTA, no differences were observed for rates of adverse cardiovascular events, including CAD hospitalizations (4.2% vs 4.1%, p = NS), CAD outpatient visits (17.4% vs 13.3%, p = NS), myocardial infarction (0.4% vs 0.6%, p = NS), and new-onset angina (3.0% vs 3.5%, p = NS). Patients without known CAD who underwent CCTA, compared with matched patients who underwent SPECT, incurred lower overall health care and CAD expenditures while experiencing similarly low rates of CAD hospitalization, outpatient visits, myocardial infarction, and angina. In conclusion, these data suggest that CCTA may be a cost-efficient alternative to SPECT for the initial coronary evaluation of patients without known CAD.
Ionospheric-thermospheric UV tomography: 2. Comparison with incoherent scatter radar measurements
NASA Astrophysics Data System (ADS)
Dymond, K. F.; Nicholas, A. C.; Budzien, S. A.; Stephan, A. W.; Coker, C.; Hei, M. A.; Groves, K. M.
2017-03-01
The Special Sensor Ultraviolet Limb Imager (SSULI) instruments are ultraviolet limb scanning sensors that fly on the Defense Meteorological Satellite Program F16-F19 satellites. The SSULIs cover the 80-170 nm wavelength range which contains emissions at 91 and 136 nm, which are produced by radiative recombination of the ionosphere. We invert the 91.1 nm emission tomographically using a newly developed algorithm that includes optical depth effects due to pure absorption and resonant scattering. We present the details of our approach including how the optimal altitude and along-track sampling were determined and the newly developed approach we are using for regularizing the SSULI tomographic inversions. Finally, we conclude with validations of the SSULI inversions against Advanced Research Project Agency Long-range Tracking and Identification Radar (ALTAIR) incoherent scatter radar measurements and demonstrate excellent agreement between the measurements. As part of this study, we include the effects of pure absorption by O2, N2, and O in the inversions and find that best agreement between the ALTAIR and SSULI measurements is obtained when only O2 and O are included, but the agreement degrades when N2 absorption is included. This suggests that the absorption cross section of N2 needs to be reinvestigated near 91.1 nm wavelengths.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Choong, W. -S.; Abu-Nimeh, F.; Moses, W. W.
Here, we present a 16-channel front-end readout board for the OpenPET electronics system. A major task in developing a nuclear medical imaging system, such as a positron emission computed tomograph (PET) or a single-photon emission computed tomograph (SPECT), is the electronics system. While there are a wide variety of detector and camera design concepts, the relatively simple nature of the acquired data allows for a common set of electronics requirements that can be met by a flexible, scalable, and high-performance OpenPET electronics system. The analog signals from the different types of detectors used in medical imaging share similar characteristics, whichmore » allows for a common analog signal processing. The OpenPET electronics processes the analog signals with Detector Boards. Here we report on the development of a 16-channel Detector Board. Each signal is digitized by a continuously sampled analog-to-digital converter (ADC), which is processed by a field programmable gate array (FPGA) to extract pulse height information. A leading edge discriminator creates a timing edge that is "time stamped" by a time-to-digital converter (TDC) implemented inside the FPGA. In conclusion, this digital information from each channel is sent to an FPGA that services 16 analog channels, and then information from multiple channels is processed by this FPGA to perform logic for crystal lookup, DOI calculation, calibration, etc.« less
Data-processing strategies for nano-tomography with elemental specification
NASA Astrophysics Data System (ADS)
Liu, Yijin; Cats, Korneel H.; Nelson Weker, Johanna; Andrews, Joy C.; Weckhuysen, Bert M.; Pianetta, Piero
2013-10-01
Combining the energy tunability provided by synchrotron X-ray sources with transmission X-ray microscopy, the morphology of materials can be resolved in 3D at spatial resolution down to 30 nm with elemental/chemical specification. In order to study the energy dependence of the absorption coefficient over the investigated volume, the tomographic reconstruction and image registration (before and/or after the tomographic reconstruction) are critical. We show in this paper the comparison of two different data processing strategies and conclude that the signal to noise ratio (S/N) in the final result can be improved via performing tomographic reconstruction prior to the evaluation of energy dependence. Our result echoes the dose fractionation theorem, and is particularly helpful when the element of interest has low concentration.
Vanderperren, K; Bergman, H J; Spoormakers, T J P; Pille, F; Duchateau, L; Puchalski, S M; Saunders, J H
2014-07-01
Lysis of the axial aspect of equine proximal sesamoid bones (PSBs) is a rare condition reported to have septic or traumatic origins. Limited information exists regarding imaging of nonseptic axial osteitis of a PSB. To report the clinical, radiographic, ultrasonographic, computed tomographic and intra-arterial contrast-enhanced computed tomographic abnormalities in horses with axial nonseptic osteitis of a PSB. Retrospective clinical study. Eighteen horses diagnosed with nonseptic osteitis of the axial border of a PSB between 2007 and 2012 were reviewed retrospectively. Case details, clinical examination, radiographic, ultrasonographic, computed tomographic and intra-arterial/intra-articular contrast-enhanced computed tomographic features were recorded, when available. Radiographic, ultrasonographic and computed tomographic evaluations of the fetlock region had been performed on 18, 15 and 9 horses, respectively. The effect of the degree of lysis on the grade and duration of lameness was determined. All horses had chronic unilateral lameness, 4 with forelimb and 14 with hindlimb signs. On radiographs, lysis was identified in both PSBs in 14 horses, one PSB in 3 horses and in one horse no lysis was identified. The degree of osteolysis was variable. Ultrasonography identified variably sized irregularities of the bone surface and alteration in echogenicity of the palmar/plantar ligament (PL). All horses undergoing computed tomographic examination (n = 9) had biaxial lysis. The lesions were significantly longer and deeper on computed tomographic images compared with radiographic images. Intra-arterial contrast-enhanced computed tomography may reveal moderate to marked contrast enhancement of the PL. There was no significant effect of the degree of lysis on the grade and duration of lameness. Lesions of nonseptic axial osteitis of a PSB can be identified using a combination of radiography and ultrasonography. Computed tomography provides additional information regarding the extent of the pathology. © 2013 EVJ Ltd.
Tafti, Bashir Akhavan; Berenji, Gholam R; Santiago, Silverio; Barack, Bruce M
2012-11-01
Computed tomographic pulmonary angiography has become the diagnostic procedure of choice in patients suspected of having a pulmonary embolus. However, intrapulmonary shunting of blood in a variety of pathologic conditions can cause suboptimal opacification of the pulmonary arterial circulation and result in a suboptimal or even nondiagnostic study. Radiologists should be aware of these conditions and be familiar with positioning techniques to minimize such shunting. We report a patient suspected of having pulmonary embolism, in whom a preexisting unilateral arteriovenous malformation prevented adequate evaluation of the pulmonary circulation. Positioning the patient in the contralateral decubitus position significantly enhanced image quality.
Koukourakis, G; Maravelis, G; Koukouraki, S; Padelakos, P; Kouloulias, V
2009-01-01
The concept of emission and transmission tomography was introduced by David Kuhl and Roy Edwards in the late 1950s. Their work later led to the design and construction of several tomographic instruments at the University of Pennsylvania. Tomographic imaging techniques were further developed by Michel Ter-Pogossian, Michael E. Phelps and others at the Washington University School of Medicine. Positron emission tomography (PET) is a nuclear medicine imaging technique which produces a 3-dimensional image or map of functional processes in the body. The system detects pairs of gamma rays emitted indirectly by a positron-emitting radionuclide (tracer), which is introduced into the body on a biologically active molecule. Images of tracer concentration in 3-dimensional space within the body are then reconstructed by computer analysis. In modern scanners, this reconstruction is often accomplished with the aid of a CT X-ray scan performed on the patient during the same session, in the same machine. If the biologically active molecule chosen for PET is 18F-fluorodeoxyglucose (FDG), an analogue of glucose, the concentrations of tracer imaged give tissue metabolic activity in terms of regional glucose uptake. Although use of this tracer results in the most common type of PET scan, other tracer molecules are used in PET to image the tissue concentration of many other types of molecules of interest. The main role of this article was to analyse the available types of radiopharmaceuticals used in PET-CT along with the principles of its clinical and technical considerations.
GATE - Geant4 Application for Tomographic Emission: a simulation toolkit for PET and SPECT
Jan, S.; Santin, G.; Strul, D.; Staelens, S.; Assié, K.; Autret, D.; Avner, S.; Barbier, R.; Bardiès, M.; Bloomfield, P. M.; Brasse, D.; Breton, V.; Bruyndonckx, P.; Buvat, I.; Chatziioannou, A. F.; Choi, Y.; Chung, Y. H.; Comtat, C.; Donnarieix, D.; Ferrer, L.; Glick, S. J.; Groiselle, C. J.; Guez, D.; Honore, P.-F.; Kerhoas-Cavata, S.; Kirov, A. S.; Kohli, V.; Koole, M.; Krieguer, M.; van der Laan, D. J.; Lamare, F.; Largeron, G.; Lartizien, C.; Lazaro, D.; Maas, M. C.; Maigne, L.; Mayet, F.; Melot, F.; Merheb, C.; Pennacchio, E.; Perez, J.; Pietrzyk, U.; Rannou, F. R.; Rey, M.; Schaart, D. R.; Schmidtlein, C. R.; Simon, L.; Song, T. Y.; Vieira, J.-M.; Visvikis, D.; Van de Walle, R.; Wieërs, E.; Morel, C.
2012-01-01
Monte Carlo simulation is an essential tool in emission tomography that can assist in the design of new medical imaging devices, the optimization of acquisition protocols, and the development or assessment of image reconstruction algorithms and correction techniques. GATE, the Geant4 Application for Tomographic Emission, encapsulates the Geant4 libraries to achieve a modular, versatile, scripted simulation toolkit adapted to the field of nuclear medicine. In particular, GATE allows the description of time-dependent phenomena such as source or detector movement, and source decay kinetics. This feature makes it possible to simulate time curves under realistic acquisition conditions and to test dynamic reconstruction algorithms. This paper gives a detailed description of the design and development of GATE by the OpenGATE collaboration, whose continuing objective is to improve, document, and validate GATE by simulating commercially available imaging systems for PET and SPECT. Large effort is also invested in the ability and the flexibility to model novel detection systems or systems still under design. A public release of GATE licensed under the GNU Lesser General Public License can be downloaded at the address http://www-lphe.ep.ch/GATE/. Two benchmarks developed for PET and SPECT to test the installation of GATE and to serve as a tutorial for the users are presented. Extensive validation of the GATE simulation platform has been started, comparing simulations and measurements on commercially available acquisition systems. References to those results are listed. The future prospects toward the gridification of GATE and its extension to other domains such as dosimetry are also discussed. PMID:15552416
Computer tomographic evaluation of digestive tract non-Hodgkin lymphomas.
Lupescu, Ioana G; Grasu, Mugur; Goldis, Gheorghe; Popa, Gelu; Gheorghe, Cristian; Vasilescu, Catalin; Moicean, Andreea; Herlea, Vlad; Georgescu, Serban A
2007-09-01
Computer Tomographic (CT) study is crucial for defining distribution, characteristics and staging of primary gastrointestinal lymphomas. The presence of multifocal sites, the wall thickening with diffuse infiltration of the affected gastrointestinal (GI) segment in association with regional adenopathies, permit the orientation of the CT diagnosis for primary GI lymphomas. The gold standard for diagnosis remains, in all cases of digestive tract non-Hodgkin lymphomas (NHL), the histological examination, which allows a tissue diagnosis, performed preferably by transmural biopsy.
NASA Astrophysics Data System (ADS)
Gu, Z.; Bao, Q.; Taschereau, R.; Wang, H.; Bai, B.; Chatziioannou, A. F.
2014-06-01
Small animal positron emission tomography (PET) systems are often designed by employing close geometry configurations. Due to the different characteristics caused by geometrical factors, these tomographs require data acquisition protocols that differ from those optimized for conventional large diameter ring systems. In this work we optimized the energy window for data acquisitions with PETbox4, a 50 mm detector separation (box-like geometry) pre-clinical PET scanner, using the Geant4 Application for Tomographic Emission (GATE). The fractions of different types of events were estimated using a voxelized phantom including a mouse as well as its supporting chamber, mimicking a realistic mouse imaging environment. Separate code was developed to extract additional information about the gamma interactions for more accurate event type classification. Three types of detector backscatter events were identified in addition to the trues, phantom scatters and randoms. The energy window was optimized based on the noise equivalent count rate (NECR) and scatter fraction (SF) with lower-level discriminators (LLD) corresponding to energies from 150 keV to 450 keV. The results were validated based on the calculated image uniformity, spillover ratio (SOR) and recovery coefficient (RC) from physical measurements using the National Electrical Manufacturers Association (NEMA) NU-4 image quality phantom. These results indicate that when PETbox4 is operated with a more narrow energy window (350-650 keV), detector backscatter rejection is unnecessary. For the NEMA NU-4 image quality phantom, the SOR for the water chamber decreases by about 45% from 15.1% to 8.3%, and the SOR for the air chamber decreases by 31% from 12.0% to 8.3% at the LLDs of 150 and 350 keV, without obvious change in uniformity, further supporting the simulation based optimization. The optimization described in this work is not limited to PETbox4, but also applicable or helpful to other small inner diameter geometry scanners.
Detection of isolated cerebrovascular beta-amyloid with Pittsburgh compound B.
Greenberg, Steven M; Grabowski, Thomas; Gurol, M Edip; Skehan, Maureen E; Nandigam, R N Kaveer; Becker, John A; Garcia-Alloza, Monica; Prada, Claudia; Frosch, Matthew P; Rosand, Jonathan; Viswanathan, Anand; Smith, Eric E; Johnson, Keith A
2008-11-01
Imaging of cerebrovascular beta-amyloid (cerebral amyloid angiopathy) is complicated by the nearly universal overlap of this pathology with Alzheimer's pathology. We performed positron emission tomographic imaging with Pittsburgh Compound B on 42-year-old man with early manifestations of Iowa-type hereditary cerebral amyloid angiopathy, a form of the disorder with little or no plaque deposits of fibrillar beta-amyloid. The results demonstrated increased Pittsburgh Compound B retention selectively in occipital cortex, sparing regions typically labeled in Alzheimer's disease. These results offer compelling evidence that Pittsburgh Compound B positron emission tomography can noninvasively detect isolated cerebral amyloid angiopathy before overt signs of tissue damage such as hemorrhage or white matter lesions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hammeschlag, S.B.; Hughes, S.; O'Reilly, G.V.
Orbital blow-out fractures were experimentally created in eight human cadavers. Each orbit underwent conventional radiographic studies, complex motion tomography, and computed tomographic examinations. A comparison of the three modalities was made. Anatomical correlation was obtained by dissecting the orbits. The significance of medial-wall fractures and enophthalmos is discussed. Limitation of inferior rectus muscle mobility is thought to be a result of muscle kinking associated with orbital fat-pad prolapse at the fracture site, rather than muscle incarceration. Blow-out fractures should be evaluated by computed tomographic computer reformations in the oblique sagittal plane.
Evaluation of a Multicore-Optimized Implementation for Tomographic Reconstruction
Agulleiro, Jose-Ignacio; Fernández, José Jesús
2012-01-01
Tomography allows elucidation of the three-dimensional structure of an object from a set of projection images. In life sciences, electron microscope tomography is providing invaluable information about the cell structure at a resolution of a few nanometres. Here, large images are required to combine wide fields of view with high resolution requirements. The computational complexity of the algorithms along with the large image size then turns tomographic reconstruction into a computationally demanding problem. Traditionally, high-performance computing techniques have been applied to cope with such demands on supercomputers, distributed systems and computer clusters. In the last few years, the trend has turned towards graphics processing units (GPUs). Here we present a detailed description and a thorough evaluation of an alternative approach that relies on exploitation of the power available in modern multicore computers. The combination of single-core code optimization, vector processing, multithreading and efficient disk I/O operations succeeds in providing fast tomographic reconstructions on standard computers. The approach turns out to be competitive with the fastest GPU-based solutions thus far. PMID:23139768
Pressure estimation from single-snapshot tomographic PIV in a turbulent boundary layer
NASA Astrophysics Data System (ADS)
Schneiders, Jan F. G.; Pröbsting, Stefan; Dwight, Richard P.; van Oudheusden, Bas W.; Scarano, Fulvio
2016-04-01
A method is proposed to determine the instantaneous pressure field from a single tomographic PIV velocity snapshot and is applied to a flat-plate turbulent boundary layer. The main concept behind the single-snapshot pressure evaluation method is to approximate the flow acceleration using the vorticity transport equation. The vorticity field calculated from the measured instantaneous velocity is advanced over a single integration time step using the vortex-in-cell (VIC) technique to update the vorticity field, after which the temporal derivative and material derivative of velocity are evaluated. The pressure in the measurement volume is subsequently evaluated by solving a Poisson equation. The procedure is validated considering data from a turbulent boundary layer experiment, obtained with time-resolved tomographic PIV at 10 kHz, where an independent surface pressure fluctuation measurement is made by a microphone. The cross-correlation coefficient of the surface pressure fluctuations calculated by the single-snapshot pressure method with respect to the microphone measurements is calculated and compared to that obtained using time-resolved pressure-from-PIV, which is regarded as benchmark. The single-snapshot procedure returns a cross-correlation comparable to the best result obtained by time-resolved PIV, which uses a nine-point time kernel. When the kernel of the time-resolved approach is reduced to three measurements, the single-snapshot method yields approximately 30 % higher correlation. Use of the method should be cautioned when the contributions to fluctuating pressure from outside the measurement volume are significant. The study illustrates the potential for simplifying the hardware configurations (e.g. high-speed PIV or dual PIV) required to determine instantaneous pressure from tomographic PIV.
A front-end readout Detector Board for the OpenPET electronics system
NASA Astrophysics Data System (ADS)
Choong, W.-S.; Abu-Nimeh, F.; Moses, W. W.; Peng, Q.; Vu, C. Q.; Wu, J.-Y.
2015-08-01
We present a 16-channel front-end readout board for the OpenPET electronics system. A major task in developing a nuclear medical imaging system, such as a positron emission computed tomograph (PET) or a single-photon emission computed tomograph (SPECT), is the electronics system. While there are a wide variety of detector and camera design concepts, the relatively simple nature of the acquired data allows for a common set of electronics requirements that can be met by a flexible, scalable, and high-performance OpenPET electronics system. The analog signals from the different types of detectors used in medical imaging share similar characteristics, which allows for a common analog signal processing. The OpenPET electronics processes the analog signals with Detector Boards. Here we report on the development of a 16-channel Detector Board. Each signal is digitized by a continuously sampled analog-to-digital converter (ADC), which is processed by a field programmable gate array (FPGA) to extract pulse height information. A leading edge discriminator creates a timing edge that is ``time stamped'' by a time-to-digital converter (TDC) implemented inside the FPGA . This digital information from each channel is sent to an FPGA that services 16 analog channels, and then information from multiple channels is processed by this FPGA to perform logic for crystal lookup, DOI calculation, calibration, etc.
Soh, Shui-Boon; Pham, Alan; O'Hehir, Robyn E; Cherk, Martin; Topliss, Duncan J
2013-09-01
A 42-year-old woman presented with a rapidly enlarging right-sided thyroid mass and underwent hemithyroidectomy. Riedel's thyroiditis was only diagnosed upon surgical decompression of the right carotid artery 2 years later. She became more symptomatic as Riedel's thyroiditis progressed, and mediastinal fibrosclerosis developed over the next 12 months. Oral prednisolone failed to improve her condition, and she was commenced on tamoxifen. Despite initial improvement, her symptoms recurred 2 years later, mainly arising from compression of the trachea and esophagus at the thoracic inlet. Fluorodeoxyglucose positron emission tomographic scan showed locally advanced active invasive fibrosclerosis in the neck and mediastinum. An elevated activin-A level of 218 pg/mL was consistent with active inflammation. IgG subtypes (including IgG4) were normal. Two courses of iv methylprednisolone were given but only produced transient improvement. Subsequently, the patient received 3 doses of i.v. rituximab at monthly intervals and had prompt sustained symptomatic improvement. Activin-A level decreased to 122 pg/mL 10 months after rituximab therapy. Fluorodeoxyglucose positron emission tomographic scan 6 weeks after therapy showed reduction in inflammation. A further scan at 10 months demonstrated ongoing response to rituximab. This is a case of refractory Riedel's thyroiditis with symptomatic, biochemical, and radiological improvement that has persisted 14 months after rituximab. The likelihood and duration of response to rituximab in Riedel's thyroiditis requires further study.
A front-end readout Detector Board for the OpenPET electronics system
Choong, W. -S.; Abu-Nimeh, F.; Moses, W. W.; ...
2015-08-12
Here, we present a 16-channel front-end readout board for the OpenPET electronics system. A major task in developing a nuclear medical imaging system, such as a positron emission computed tomograph (PET) or a single-photon emission computed tomograph (SPECT), is the electronics system. While there are a wide variety of detector and camera design concepts, the relatively simple nature of the acquired data allows for a common set of electronics requirements that can be met by a flexible, scalable, and high-performance OpenPET electronics system. The analog signals from the different types of detectors used in medical imaging share similar characteristics, whichmore » allows for a common analog signal processing. The OpenPET electronics processes the analog signals with Detector Boards. Here we report on the development of a 16-channel Detector Board. Each signal is digitized by a continuously sampled analog-to-digital converter (ADC), which is processed by a field programmable gate array (FPGA) to extract pulse height information. A leading edge discriminator creates a timing edge that is "time stamped" by a time-to-digital converter (TDC) implemented inside the FPGA. In conclusion, this digital information from each channel is sent to an FPGA that services 16 analog channels, and then information from multiple channels is processed by this FPGA to perform logic for crystal lookup, DOI calculation, calibration, etc.« less
Giacomelli, L; Conroy, S; Gorini, G; Horton, L; Murari, A; Popovichev, S; Syme, D B
2014-02-01
The Joint European Torus (JET, Culham, UK) is the largest tokamak in the world devoted to nuclear fusion experiments of magnetic confined Deuterium (D)/Deuterium-Tritium (DT) plasmas. Neutrons produced in these plasmas are measured using various types of neutron detectors and spectrometers. Two of these instruments on JET make use of organic liquid scintillator detectors. The neutron emission profile monitor implements 19 liquid scintillation counters to detect the 2.45 MeV neutron emission from D plasmas. A new compact neutron spectrometer is operational at JET since 2010 to measure the neutron energy spectra from both D and DT plasmas. Liquid scintillation detectors are sensitive to both neutron and gamma radiation but give light responses of different decay time such that pulse shape discrimination techniques can be applied to identify the neutron contribution of interest from the data. The most common technique consists of integrating the radiation pulse shapes within different ranges of their rising and/or trailing edges. In this article, a step forward in this type of analysis is presented. The method applies a tomographic analysis of the 3-dimensional neutron and gamma pulse shape and pulse height distribution data obtained from liquid scintillation detectors such that n/γ discrimination can be improved to lower energies and additional information can be gained on neutron contributions to the gamma events and vice versa.
Estimating crustal heterogeneity from double-difference tomography
Got, J.-L.; Monteiller, V.; Virieux, J.; Okubo, P.
2006-01-01
Seismic velocity parameters in limited, but heterogeneous volumes can be inferred using a double-difference tomographic algorithm, but to obtain meaningful results accuracy must be maintained at every step of the computation. MONTEILLER et al. (2005) have devised a double-difference tomographic algorithm that takes full advantage of the accuracy of cross-spectral time-delays of large correlated event sets. This algorithm performs an accurate computation of theoretical travel-time delays in heterogeneous media and applies a suitable inversion scheme based on optimization theory. When applied to Kilauea Volcano, in Hawaii, the double-difference tomography approach shows significant and coherent changes to the velocity model in the well-resolved volumes beneath the Kilauea caldera and the upper east rift. In this paper, we first compare the results obtained using MONTEILLER et al.'s algorithm with those obtained using the classic travel-time tomographic approach. Then, we evaluated the effect of using data series of different accuracies, such as handpicked arrival-time differences ("picking differences"), on the results produced by double-difference tomographic algorithms. We show that picking differences have a non-Gaussian probability density function (pdf). Using a hyperbolic secant pdf instead of a Gaussian pdf allows improvement of the double-difference tomographic result when using picking difference data. We completed our study by investigating the use of spatially discontinuous time-delay data. ?? Birkha??user Verlag, Basel, 2006.
Prabhakar, Attiguppe R; Yavagal, Chandrashekar; Dixit, Kratika; Naik, Saraswathi V
2016-01-01
Primary root canals are considered to be most challenging due to their complex anatomy. "Wave one" and "one shape" are single-file systems with reciprocating and rotary motion respectively. The aim of this study was to evaluate and compare dentin thickness, centering ability, canal transportation, and instrumentation time of wave one and one shape files in primary root canals using a cone beam computed tomographic (CBCT) analysis. This is an experimental, in vitro study comparing the two groups. A total of 24 extracted human primary teeth with minimum 7 mm root length were included in the study. Cone beam computed tomographic images were taken before and after the instrumentation for each group. Dentin thickness, centering ability, canal transportation, and instrumentation times were evaluated for each group. A significant difference was found in instrumentation time and canal transportation measures between the two groups. Wave one showed less canal transportation as compared with one shape, and the mean instrumentation time of wave one was significantly less than one shape. Reciprocating single-file systems was found to be faster with much less procedural errors and can hence be recommended for shaping the root canals of primary teeth. How to cite this article: Prabhakar AR, Yavagal C, Dixit K, Naik SV. Reciprocating vs Rotary Instrumentation in Pediatric Endodontics: Cone Beam Computed Tomographic Analysis of Deciduous Root Canals using Two Single-File Systems. Int J Clin Pediatr Dent 2016;9(1):45-49.
Trace: a high-throughput tomographic reconstruction engine for large-scale datasets.
Bicer, Tekin; Gürsoy, Doğa; Andrade, Vincent De; Kettimuthu, Rajkumar; Scullin, William; Carlo, Francesco De; Foster, Ian T
2017-01-01
Modern synchrotron light sources and detectors produce data at such scale and complexity that large-scale computation is required to unleash their full power. One of the widely used imaging techniques that generates data at tens of gigabytes per second is computed tomography (CT). Although CT experiments result in rapid data generation, the analysis and reconstruction of the collected data may require hours or even days of computation time with a medium-sized workstation, which hinders the scientific progress that relies on the results of analysis. We present Trace, a data-intensive computing engine that we have developed to enable high-performance implementation of iterative tomographic reconstruction algorithms for parallel computers. Trace provides fine-grained reconstruction of tomography datasets using both (thread-level) shared memory and (process-level) distributed memory parallelization. Trace utilizes a special data structure called replicated reconstruction object to maximize application performance. We also present the optimizations that we apply to the replicated reconstruction objects and evaluate them using tomography datasets collected at the Advanced Photon Source. Our experimental evaluations show that our optimizations and parallelization techniques can provide 158× speedup using 32 compute nodes (384 cores) over a single-core configuration and decrease the end-to-end processing time of a large sinogram (with 4501 × 1 × 22,400 dimensions) from 12.5 h to <5 min per iteration. The proposed tomographic reconstruction engine can efficiently process large-scale tomographic data using many compute nodes and minimize reconstruction times.
Water vapour tomography using GPS phase observations: Results from the ESCOMPTE experiment
NASA Astrophysics Data System (ADS)
Nilsson, T.; Gradinarsky, L.; Elgered, G.
2007-10-01
Global Positioning System (GPS) tomography is a technique for estimating the 3-D structure of the atmospheric water vapour using data from a dense local network of GPS receivers. Several current methods utilize estimates of slant wet delays between the GPS satellites and the receivers on the ground, which are difficult to obtain with millimetre accuracy from the GPS observations. We present results of applying a new tomographic method to GPS data from the Expériance sur site pour contraindre les modèles de pollution atmosphérique et de transport d'emissions (ESCOMPTE) experiment in southern France. This method does not rely on any slant wet delay estimates, instead it uses the GPS phase observations directly. We show that the estimated wet refractivity profiles estimated by this method is on the same accuracy level or better compared to other tomographic methods. The results are in agreement with earlier simulations, for example the profile information is limited above 4 km.
SU-C-209-07: Phantoms for Digital Breast Tomosynthesis Imaging System Evaluation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jacobson, D; Liu, Y
2016-06-15
Purpose: Digital Breast Tomosynthesis (DBT) is gaining importance in breast imaging. There is a need for phantoms that can be used for image evaluation and comparison. Existing commercially available phantoms for DBT are expensive and may lack clinically relevant test objects. The purpose of this study is to develop phantoms for DBT evaluation. Methods Four phantoms have been designed and constructed to assess the image quality (IQ) of two DBT systems. The first contains a spiral of 0.3 mm SiC beads in gelatin to measure the tomographic slice thickness profile and uniformity of coverage in a series of tomographic planes.more » The second contains simulated tumors inclined with respect to the phantom base to assess tomographic image quality. The third has a tilted array of discs with varying contrast and diameter. This phantom was imaged alone and in a stack of TE slabs giving 2 to 10 cm thickness. The fourth has a dual wedge of glandular and adipose simulating materials. One wedge contains discs with varying diameter and thickness; the other supports a mass with six simulated spicules of varying size and a cluster of simulated calcifications. The simulated glandular tissue material varies between 35 and 100% of the total thickness (5.5 cm). Results: All phantoms were scanned successfully. The best IQ comparison was achieved with the dual wedge phantom as demonstrated by the spiculated mass and calcifications. Images were evaluated by two radiologists and one physicist. The projection images and corresponding set of tomographic planes were comparable and the synthesized projection images were inferior to the projection images for both systems. Conclusion: Four phantoms were designed, constructed and imaged on two DBT systems. They successfully demonstrated performance differences between two systems, and between true and synthesized projection images. Future work will incorporate these designs into a single phantom.« less
Pressure spectra from single-snapshot tomographic PIV
NASA Astrophysics Data System (ADS)
Schneiders, Jan F. G.; Avallone, Francesco; Pröbsting, Stefan; Ragni, Daniele; Scarano, Fulvio
2018-03-01
The power spectral density and coherence of temporal pressure fluctuations are obtained from low-repetition-rate tomographic PIV measurements. This is achieved by extension of recent single-snapshot pressure evaluation techniques based upon the Taylor's hypothesis (TH) of frozen turbulence and vortex-in-cell (VIC) simulation. Finite time marching of the measured instantaneous velocity fields is performed using TH and VIC. Pressure is calculated from the resulting velocity time series. Because of the theoretical limitations, the finite time marching can be performed until the measured flow structures are convected out of the measurement volume. This provides a lower limit of resolvable frequency range. An upper limit is given by the spatial resolution of the measurements. Finite time-marching approaches are applied to low-repetition-rate tomographic PIV data of the flow past a straight trailing edge at 10 m/s. Reference results of the power spectral density and coherence are obtained from surface pressure transducers. In addition, the results are compared to state-of-the-art experimental data obtained from time-resolved tomographic PIV performed at 10 kHz. The time-resolved approach suffers from low spatial resolution and limited maximum acquisition frequency because of hardware limitations. Additionally, these approaches strongly depend upon the time kernel length chosen for pressure evaluation. On the other hand, the finite time-marching approaches make use of low-repetition-rate tomographic PIV measurements that offer higher spatial resolution. Consequently, increased accuracy of the power spectral density and coherence of pressure fluctuations are obtained in the high-frequency range, in comparison to the time-resolved measurements. The approaches based on TH and VIC are found to perform similarly in the high-frequency range. At lower frequencies, TH is found to underestimate coherence and intensity of the pressure fluctuations in comparison to time-resolved PIV and the microphone reference data. The VIC-based approach, on the other hand, returns results on the order of the reference.
Dental optical tomography with upconversion nanoparticles—a feasibility study
Long, Feixiao; Intes, Xavier
2017-01-01
Abstract. Upconversion nanoparticles (UCNPs) have the unique ability to emit multiple colors upon excitation by near-infrared (NIR) light. Herein, we investigate the potential use of UCNPs as contrast agents for dental optical tomography, with a focus on monitoring the status of fillings after dental restoration. The potential of performing tomographic imaging using UCNP emission of visible or NIR light is established. This in silico and ex vivo study paves the way toward employing UCNPs as theranostic agents for dental applications. PMID:28586852
1983-02-23
Annihilation Techniques SONIA MIIAN S., R. ZANA , J.CH. ABBE, and G. DUPLATRE - xxviii P-80 Study of Microemulsion Systems by Positron Annihilation...California, Berkeley CA 94720, U.S.A. Primary considerations for the design of positron emission tomographs for medical studies in humans are high...imaging system for medical applications is to produce an image in as short as time as possible which represents as accurately Ias possible the
Commissioning of the J-PET Detector for Studies of Decays of Positronium Atoms
NASA Astrophysics Data System (ADS)
Czerwiński, E.; Dulski, K.; Białas, P.; Curceanu, C.; Gajos, A.; Głowacz, B.; Gorgol, M.; Hiesmayr, B. C.; Jasińska, B.; Kisielewska, D.; Korcyl, G.; Kowalski, P.; Kozik, T.; Krawczyk, N.; Krzemień, W.; Kubicz, E.; Mohammed, M.; Niedźwiecki, Sz.; Pałka, M.; Pawlik-Niedźwiecka, M.; Raczyński, L.; Rudy, Z.; Sharma, N. G.; Sharma, S.; Shopa, R. Y.; Silarski, M.; Skurzok, M.; Wieczorek, A.; Wiślicki, W.; Zgardzińska, B.; Zieliński, M.; Moskal, P.
The Jagiellonian Positron Emission Tomograph (J-PET) is a detector for medical imaging of the whole human body as well as for physics studies involving detection of electron-positron annihilation into photons. J-PET has high angular and time resolution and allows for measurement of spin of the positronium and the momenta and polarization vectors of annihilation quanta. In this article, we present the potential of the J-PET system for background rejection in the decays of positronium atoms.
Dental optical tomography with upconversion nanoparticles—a feasibility study
NASA Astrophysics Data System (ADS)
Long, Feixiao; Intes, Xavier
2017-06-01
Upconversion nanoparticles (UCNPs) have the unique ability to emit multiple colors upon excitation by near-infrared (NIR) light. Herein, we investigate the potential use of UCNPs as contrast agents for dental optical tomography, with a focus on monitoring the status of fillings after dental restoration. The potential of performing tomographic imaging using UCNP emission of visible or NIR light is established. This in silico and ex vivo study paves the way toward employing UCNPs as theranostic agents for dental applications.
Dental optical tomography with upconversion nanoparticles-a feasibility study.
Long, Feixiao; Intes, Xavier
2017-06-01
Upconversion nanoparticles (UCNPs) have the unique ability to emit multiple colors upon excitation by near-infrared (NIR) light. Herein, we investigate the potential use of UCNPs as contrast agents for dental optical tomography, with a focus on monitoring the status of fillings after dental restoration. The potential of performing tomographic imaging using UCNP emission of visible or NIR light is established. This in silico and ex vivo study paves the way toward employing UCNPs as theranostic agents for dental applications.
Image intensifier-based volume tomographic angiography imaging system: system evaluation
NASA Astrophysics Data System (ADS)
Ning, Ruola; Wang, Xiaohui; Shen, Jianjun; Conover, David L.
1995-05-01
An image intensifier-based rotational volume tomographic angiography imaging system has been constructed. The system consists of an x-ray tube and an image intensifier that are separately mounted on a gantry. This system uses an image intensifier coupled to a TV camera as a two-dimensional detector so that a set of two-dimensional projections can be acquired for a direct three-dimensional reconstruction (3D). This system has been evaluated with two phantoms: a vascular phantom and a monkey head cadaver. One hundred eighty projections of each phantom were acquired with the system. A set of three-dimensional images were directly reconstructed from the projection data. The experimental results indicate that good imaging quality can be obtained with this system.
Simulated Biomass Retrieval from the Spaceborne Tomographic SAOCOM-CS Mission at L-Band
NASA Astrophysics Data System (ADS)
Blomberg, Erik; Soja, Maciej J.; Ferro-Famil, Laurent; Ulander, Lars M. H.; Tebaldini, Stefano
2016-08-01
This paper presents an evaluation of above-ground biomass (ABG) retrieval in boreal forests using simulated tomographic synthetic-aperture radar (SAR) data corresponding to the future SAOCOM-CS (L-band 1.275 GHz) mission. Using forest and radar data from the BioSAR 2008 campaign at the Krycklan test site in northern Sweden the expected performance of SAOCOM-CS is evaluated and compared with the E-SAR airborne L- band SAR (1.300 GHz). It is found that SAOCOM-CS data produce retrievals on par with those obtained with E-SAR, with retrievals having a relative RMSE of 30% or less. This holds true even if the acquisitions are limited to a single polarization, with HH results shown as an example.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pearlberg, J.L.; Sandler, M.A.; Kvale, P.
1985-03-01
Laser therapy is a new modality for treatment of airway lesions. The authors examined 18 patients prior to laser photoresection of tracheobronchial lesions. Thirteen had cancers involving the distal trachea, carina, and/or proximal bronchi; five had benign lesions of the middle or proximal trachea. Each patient was examined by conventional linear tomography (CLT) and computed tomography (CT). CT was valuable in patients who had lesions of the distal trachea, carina, and/or proximal bronchi. Its particular usefulness, and its advantage relative to CLT, consisted in its ability to delineate vascular structures adjacent to the planned area of photoresection. Neither CLT normore » CT was helpful in evaluation of benign lesions of the proximal trachea.« less
IDIOS: An innovative index for evaluating dental imaging-based osteoporosis screening indices.
Barngkgei, Imad; Halboub, Esam; Almashraqi, Abeer Abdulkareem; Khattab, Razan; Al Haffar, Iyad
2016-09-01
The goal of this study was to develop a new index as an objective reference for evaluating current and newly developed indices used for osteoporosis screening based on dental images. Its name; IDIOS, stands for Index of Dental-imaging Indices of Osteoporosis Screening. A comprehensive PubMed search was conducted to retrieve studies on dental imaging-based indices for osteoporosis screening. The results of the eligible studies, along with other relevant criteria, were used to develop IDIOS, which has scores ranging from 0 (0%) to 15 (100%). The indices presented in the studies we included were then evaluated using IDIOS. The 104 studies that were included utilized 24, 4, and 9 indices derived from panoramic, periapical, and computed tomographic/cone-beam computed tomographic techniques, respectively. The IDIOS scores for these indices ranged from 0 (0%) to 11.75 (78.32%). IDIOS is a valuable reference index that facilitates the evaluation of other dental imaging-based osteoporosis screening indices. Furthermore, IDIOS can be utilized to evaluate the accuracy of newly developed indices.
NASA Astrophysics Data System (ADS)
Dudak, J.; Zemlicka, J.; Krejci, F.; Karch, J.; Patzelt, M.; Zach, P.; Sykora, V.; Mrzilkova, J.
2016-03-01
X-ray microradiography and microtomography are imaging techniques with increasing applicability in the field of biomedical and preclinical research. Application of hybrid pixel detector Timepix enables to obtain very high contrast of low attenuating materials such as soft biological tissue. However X-ray imaging of ex-vivo soft tissue samples is a difficult task due to its structural instability. Ex-vivo biological tissue is prone to fast drying-out which is connected with undesired changes of sample size and shape producing later on artefacts within the tomographic reconstruction. In this work we present the optimization of our Timepix equipped micro-CT system aiming to maintain soft tissue sample in stable condition. Thanks to the suggested approach higher contrast of tomographic reconstructions can be achieved while also large samples that require detector scanning can be easily measured.
Hybrid Gama Emission Tomography (HGET): FY16 Annual Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Miller, Erin A.; Smith, Leon E.; Wittman, Richard S.
2017-02-01
Current International Atomic Energy Agency (IAEA) methodologies for the verification of fresh low-enriched uranium (LEU) and mixed oxide (MOX) fuel assemblies are volume-averaging methods that lack sensitivity to individual pins. Further, as fresh fuel assemblies become more and more complex (e.g., heavy gadolinium loading, high degrees of axial and radial variation in fissile concentration), the accuracy of current IAEA instruments degrades and measurement time increases. Particularly in light of the fact that no special tooling is required to remove individual pins from modern fuel assemblies, the IAEA needs new capabilities for the verification of unirradiated (i.e., fresh LEU and MOX)more » assemblies to ensure that fissile material has not been diverted. Passive gamma emission tomography has demonstrated potential to provide pin-level verification of spent fuel, but gamma-ray emission rates from unirradiated fuel emissions are significantly lower, precluding purely passive tomography methods. The work presented here introduces the concept of Hybrid Gamma Emission Tomography (HGET) for verification of unirradiated fuels, in which a neutron source is used to actively interrogate the fuel assembly and the resulting gamma-ray emissions are imaged using tomographic methods to provide pin-level verification of fissile material concentration.« less
Cho, Iksung; Al'Aref, Subhi J; Berger, Adam; Ó Hartaigh, Bríain; Gransar, Heidi; Valenti, Valentina; Lin, Fay Y; Achenbach, Stephan; Berman, Daniel S; Budoff, Matthew J; Callister, Tracy Q; Al-Mallah, Mouaz H; Cademartiri, Filippo; Chinnaiyan, Kavitha; Chow, Benjamin J W; DeLago, Augustin; Villines, Todd C; Hadamitzky, Martin; Hausleiter, Joerg; Leipsic, Jonathon; Shaw, Leslee J; Kaufmann, Philipp A; Feuchtner, Gudrun; Kim, Yong-Jin; Maffei, Erica; Raff, Gilbert; Pontone, Gianluca; Andreini, Daniele; Marques, Hugo; Rubinshtein, Ronen; Chang, Hyuk-Jae; Min, James K
2018-03-14
The long-term prognostic benefit of coronary computed tomographic angiography (CCTA) findings of coronary artery disease (CAD) in asymptomatic populations is unknown. From the prospective multicentre international CONFIRM long-term study, we evaluated asymptomatic subjects without known CAD who underwent both coronary artery calcium scoring (CACS) and CCTA (n = 1226). Coronary computed tomographic angiography findings included the severity of coronary artery stenosis, plaque composition, and coronary segment location. Using the C-statistic and likelihood ratio tests, we evaluated the incremental prognostic utility of CCTA findings over a base model that included a panel of traditional risk factors (RFs) as well as CACS to predict long-term all-cause mortality. During a mean follow-up of 5.9 ± 1.2 years, 78 deaths occurred. Compared with the traditional RF alone (C-statistic 0.64), CCTA findings including coronary stenosis severity, plaque composition, and coronary segment location demonstrated improved incremental prognostic utility beyond traditional RF alone (C-statistics range 0.71-0.73, all P < 0.05; incremental χ2 range 20.7-25.5, all P < 0.001). However, no added prognostic benefit was offered by CCTA findings when added to a base model containing both traditional RF and CACS (C-statistics P > 0.05, for all). Coronary computed tomographic angiography improved prognostication of 6-year all-cause mortality beyond a set of conventional RF alone, although, no further incremental value was offered by CCTA when CCTA findings were added to a model incorporating RF and CACS.
Prabhakar, Attiguppe R; Yavagal, Chandrashekar; Naik, Saraswathi V
2016-01-01
ABSTRACT Background: Primary root canals are considered to be most challenging due to their complex anatomy. "Wave one" and "one shape" are single-file systems with reciprocating and rotary motion respectively. The aim of this study was to evaluate and compare dentin thickness, centering ability, canal transportation, and instrumentation time of wave one and one shape files in primary root canals using a cone beam computed tomographic (CBCT) analysis. Study design: This is an experimental, in vitro study comparing the two groups. Materials and methods: A total of 24 extracted human primary teeth with minimum 7 mm root length were included in the study. Cone beam computed tomographic images were taken before and after the instrumentation for each group. Dentin thickness, centering ability, canal transportation, and instrumentation times were evaluated for each group. Results: A significant difference was found in instrumentation time and canal transportation measures between the two groups. Wave one showed less canal transportation as compared with one shape, and the mean instrumentation time of wave one was significantly less than one shape. Conclusion: Reciprocating single-file systems was found to be faster with much less procedural errors and can hence be recommended for shaping the root canals of primary teeth. How to cite this article: Prabhakar AR, Yavagal C, Dixit K, Naik SV. Reciprocating vs Rotary Instrumentation in Pediatric Endodontics: Cone Beam Computed Tomographic Analysis of Deciduous Root Canals using Two Single-File Systems. Int J Clin Pediatr Dent 2016;9(1):45-49. PMID:27274155
Harjula, A; Järvinen, A; Mattila, S; Porkka, L
1985-01-01
Single photon emission computerized tomography (SPECT) was performed thrice in ten patients undergoing open-heart surgery--preoperatively and 2 and 12 weeks postoperatively. The operations were done for ischemic heart disease (5), aortic valvular stenosis (2), aortic valvular insufficiency (1), leaking mitral prosthetic valve (1) and combined aortic and mitral valvular stenosis and insufficiency (1). The healing process in the longitudinally divided sternum was evaluated from the SPECT study. Four conventional static images in two dimensions were registered in anteroposterior, posteroanterior and left and right lateral projections. A tomographic study was done. Quantitative analyses were performed. The ratio of the sternal counts to the counts from a thoracic vertebra was calculated for use as a reference. The activity ratios showed a similar pattern in six cases, with initial increases and at 12 weeks slight decrease compared with the preoperative values. In two cases the activity was still increasing after 12 postoperative weeks. One patient, with sternotomy also one year previously, showed only slightly increased activity. The activity at the areas of the sternal wires was increased in six cases. The study thus revealed differing patterns of isotope uptake, although recovery was uneventful in all patients. The differences may reflect the possibility that the operative course and the preoperative clinical status can influence the healing mechanisms.
Preliminary results of a prototype C-shaped PET designed for an in-beam PET system
NASA Astrophysics Data System (ADS)
Kim, Hyun-Il; Chung, Yong Hyun; Lee, Kisung; Kim, Kyeong Min; Kim, Yongkwon; Joung, Jinhun
2016-06-01
Positron emission tomography (PET) can be utilized in particle beam therapy to verify the dose distribution of the target volume as well as the accuracy of the treatment. We present an in-beam PET scanner that can be integrated into a particle beam therapy system. The proposed PET scanner consisted of 14 detector modules arranged in a C-shape to avoid blockage of the particle beam line by the detector modules. Each detector module was composed of a 9×9 array of 4.0 mm×4.0 mm×20.0 mm LYSO crystals optically coupled to four 29-mm-diameter PMTs using the photomultiplier-quadrant-sharing (PQS) technique. In this study, a Geant4 Application for Tomographic Emission (GATE) simulation study was conducted to design a C-shaped PET scanner and then experimental evaluation of the proposed design was performed. The spatial resolution and sensitivity were measured according to NEMA NU2-2007 standards and were 6.1 mm and 5.61 cps/kBq, respectively, which is in good agreement with our simulation, with an error rate of 12.0%. Taken together, our results demonstrate the feasibility of the proposed C-shaped in-beam PET system, which we expect will be useful for measuring dose distribution in particle therapy.
New method to analyze internal disruptions with tomographic reconstructions
NASA Astrophysics Data System (ADS)
Tanzi, C. P.; de Blank, H. J.
1997-03-01
Sawtooth crashes have been investigated on the Rijnhuizen Tokamak Project (RTP) [N. J. Lopes Cardozo et al., Proceedings of the 14th International Conference on Plasma Physics and Controlled Nuclear Fusion Research, Würzburg, 1992 (International Atomic Energy Agency, Vienna, 1993), Vol. 1, p. 271]. Internal disruptions in tokamak plasmas often exhibit an m=1 poloidal mode structure prior to the collapse which can be clearly identified by means of multicamera soft x-ray diagnostics. In this paper tomographic reconstructions of such m=1 modes are analyzed with a new method, based on magnetohydrodynamic (MHD) invariants computed from the two-dimensional emissivity profiles, which quantifies the amount of profile flattening not only after the crash but also during the precursor oscillations. The results are interpreted by comparing them with two models which simulate the measurements of the m=1 redistribution of soft x-ray emissivity prior to the sawtooth crash. One model is based on the magnetic reconnection model of Kadomtsev. The other involves ideal MHD motion only. In cases where differences in magnetic topology between the two models cannot be seen in the tomograms, the analysis of profile flattening has an advantage. The analysis shows that in RTP the clearly observed m=1 displacement of some sawteeth requires the presence of convective ideal MHD motion, whereas other precursors are consistent with magnetic reconnection of up to 75% of the magnetic flux within the q=1 surface. The possibility of ideal interchange combined with enhanced cross-field transport is not excluded.
Moosavi Tayebi, Rohollah; Wirza, Rahmita; Sulaiman, Puteri S B; Dimon, Mohd Zamrin; Khalid, Fatimah; Al-Surmi, Aqeel; Mazaheri, Samaneh
2015-04-22
Computerized tomographic angiography (3D data representing the coronary arteries) and X-ray angiography (2D X-ray image sequences providing information about coronary arteries and their stenosis) are standard and popular assessment tools utilized for medical diagnosis of coronary artery diseases. At present, the results of both modalities are individually analyzed by specialists and it is difficult for them to mentally connect the details of these two techniques. The aim of this work is to assist medical diagnosis by providing specialists with the relationship between computerized tomographic angiography and X-ray angiography. In this study, coronary arteries from two modalities are registered in order to create a 3D reconstruction of the stenosis position. The proposed method starts with coronary artery segmentation and labeling for both modalities. Then, stenosis and relevant labeled artery in X-ray angiography image are marked by a specialist. Proper control points for the marked artery in both modalities are automatically detected and normalized. Then, a geometrical transformation function is computed using these control points. Finally, this function is utilized to register the marked artery from the X-ray angiography image on the computerized tomographic angiography and get the 3D position of the stenosis lesion. The result is a 3D informative model consisting of stenosis and coronary arteries' information from the X-ray angiography and computerized tomographic angiography modalities. The results of the proposed method for coronary artery segmentation, labeling and 3D reconstruction are evaluated and validated on the dataset containing both modalities. The advantage of this method is to aid specialists to determine a visual relationship between the correspondent coronary arteries from two modalities and also set up a connection between stenosis points from an X-ray angiography along with their 3D positions on the coronary arteries from computerized tomographic angiography. Moreover, another benefit of this work is that the medical acquisition standards remain unchanged, which means that no calibration in the acquisition devices is required. It can be applied on most computerized tomographic angiography and angiography devices.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hou, Z; Terry, N; Hubbard, S S
2013-02-12
In this study, we evaluate the possibility of monitoring soil moisture variation using tomographic ground penetrating radar travel time data through Bayesian inversion, which is integrated with entropy memory function and pilot point concepts, as well as efficient sampling approaches. It is critical to accurately estimate soil moisture content and variations in vadose zone studies. Many studies have illustrated the promise and value of GPR tomographic data for estimating soil moisture and associated changes, however, challenges still exist in the inversion of GPR tomographic data in a manner that quantifies input and predictive uncertainty, incorporates multiple data types, handles non-uniquenessmore » and nonlinearity, and honors time-lapse tomograms collected in a series. To address these challenges, we develop a minimum relative entropy (MRE)-Bayesian based inverse modeling framework that non-subjectively defines prior probabilities, incorporates information from multiple sources, and quantifies uncertainty. The framework enables us to estimate dielectric permittivity at pilot point locations distributed within the tomogram, as well as the spatial correlation range. In the inversion framework, MRE is first used to derive prior probability distribution functions (pdfs) of dielectric permittivity based on prior information obtained from a straight-ray GPR inversion. The probability distributions are then sampled using a Quasi-Monte Carlo (QMC) approach, and the sample sets provide inputs to a sequential Gaussian simulation (SGSim) algorithm that constructs a highly resolved permittivity/velocity field for evaluation with a curved-ray GPR forward model. The likelihood functions are computed as a function of misfits, and posterior pdfs are constructed using a Gaussian kernel. Inversion of subsequent time-lapse datasets combines the Bayesian estimates from the previous inversion (as a memory function) with new data. The memory function and pilot point design takes advantage of the spatial-temporal correlation of the state variables. We first apply the inversion framework to a static synthetic example and then to a time-lapse GPR tomographic dataset collected during a dynamic experiment conducted at the Hanford Site in Richland, WA. We demonstrate that the MRE-Bayesian inversion enables us to merge various data types, quantify uncertainty, evaluate nonlinear models, and produce more detailed and better resolved estimates than straight-ray based inversion; therefore, it has the potential to improve estimates of inter-wellbore dielectric permittivity and soil moisture content and to monitor their temporal dynamics more accurately.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hou, Zhangshuan; Terry, Neil C.; Hubbard, Susan S.
2013-02-22
In this study, we evaluate the possibility of monitoring soil moisture variation using tomographic ground penetrating radar travel time data through Bayesian inversion, which is integrated with entropy memory function and pilot point concepts, as well as efficient sampling approaches. It is critical to accurately estimate soil moisture content and variations in vadose zone studies. Many studies have illustrated the promise and value of GPR tomographic data for estimating soil moisture and associated changes, however, challenges still exist in the inversion of GPR tomographic data in a manner that quantifies input and predictive uncertainty, incorporates multiple data types, handles non-uniquenessmore » and nonlinearity, and honors time-lapse tomograms collected in a series. To address these challenges, we develop a minimum relative entropy (MRE)-Bayesian based inverse modeling framework that non-subjectively defines prior probabilities, incorporates information from multiple sources, and quantifies uncertainty. The framework enables us to estimate dielectric permittivity at pilot point locations distributed within the tomogram, as well as the spatial correlation range. In the inversion framework, MRE is first used to derive prior probability density functions (pdfs) of dielectric permittivity based on prior information obtained from a straight-ray GPR inversion. The probability distributions are then sampled using a Quasi-Monte Carlo (QMC) approach, and the sample sets provide inputs to a sequential Gaussian simulation (SGSIM) algorithm that constructs a highly resolved permittivity/velocity field for evaluation with a curved-ray GPR forward model. The likelihood functions are computed as a function of misfits, and posterior pdfs are constructed using a Gaussian kernel. Inversion of subsequent time-lapse datasets combines the Bayesian estimates from the previous inversion (as a memory function) with new data. The memory function and pilot point design takes advantage of the spatial-temporal correlation of the state variables. We first apply the inversion framework to a static synthetic example and then to a time-lapse GPR tomographic dataset collected during a dynamic experiment conducted at the Hanford Site in Richland, WA. We demonstrate that the MRE-Bayesian inversion enables us to merge various data types, quantify uncertainty, evaluate nonlinear models, and produce more detailed and better resolved estimates than straight-ray based inversion; therefore, it has the potential to improve estimates of inter-wellbore dielectric permittivity and soil moisture content and to monitor their temporal dynamics more accurately.« less
Wavelet compression of noisy tomographic images
NASA Astrophysics Data System (ADS)
Kappeler, Christian; Mueller, Stefan P.
1995-09-01
3D data acquisition is increasingly used in positron emission tomography (PET) to collect a larger fraction of the emitted radiation. A major practical difficulty with data storage and transmission in 3D-PET is the large size of the data sets. A typical dynamic study contains about 200 Mbyte of data. PET images inherently have a high level of photon noise and therefore usually are evaluated after being processed by a smoothing filter. In this work we examined lossy compression schemes under the postulate not induce image modifications exceeding those resulting from low pass filtering. The standard we will refer to is the Hanning filter. Resolution and inhomogeneity serve as figures of merit for quantification of image quality. The images to be compressed are transformed to a wavelet representation using Daubechies12 wavelets and compressed after filtering by thresholding. We do not include further compression by quantization and coding here. Achievable compression factors at this level of processing are thirty to fifty.
Validation of a Monte Carlo simulation of the Inveon PET scanner using GATE
NASA Astrophysics Data System (ADS)
Lu, Lijun; Zhang, Houjin; Bian, Zhaoying; Ma, Jianhua; Feng, Qiangjin; Chen, Wufan
2016-08-01
The purpose of this study is to validate the application of GATE (Geant4 Application for Tomographic Emission) Monte Carlo simulation toolkit in order to model the performance characteristics of Siemens Inveon small animal PET system. The simulation results were validated against experimental/published data in accordance with the NEMA NU-4 2008 protocol for standardized evaluation of spatial resolution, sensitivity, scatter fraction (SF) and noise equivalent counting rate (NECR) of a preclinical PET system. An agreement of less than 18% was obtained between the radial, tangential and axial spatial resolutions of the simulated and experimental results. The simulated peak NECR of mouse-size phantom agreed with the experimental result, while for the rat-size phantom simulated value was higher than experimental result. The simulated and experimental SFs of mouse- and rat- size phantom both reached an agreement of less than 2%. It has been shown the feasibility of our GATE model to accurately simulate, within certain limits, all major performance characteristics of Inveon PET system.
Simulation of Medical Imaging Systems: Emission and Transmission Tomography
NASA Astrophysics Data System (ADS)
Harrison, Robert L.
Simulation is an important tool in medical imaging research. In patient scans the true underlying anatomy and physiology is unknown. We have no way of knowing in a given scan how various factors are confounding the data: statistical noise; biological variability; patient motion; scattered radiation, dead time, and other data contaminants. Simulation allows us to isolate a single factor of interest, for instance when researchers perform multiple simulations of the same imaging situation to determine the effect of statistical noise or biological variability. Simulations are also increasingly used as a design optimization tool for tomographic scanners. This article gives an overview of the mechanics of emission and transmission tomography simulation, reviews some of the publicly available simulation tools, and discusses trade-offs between the accuracy and efficiency of simulations.
NASA Astrophysics Data System (ADS)
Liu, Shuangquan; Zhang, Bin; Wang, Xin; Li, Lin; Chen, Yan; Liu, Xin; Liu, Fei; Shan, Baoci; Bai, Jing
2011-02-01
A dual-modality imaging system for simultaneous fluorescence molecular tomography (FMT) and positron emission tomography (PET) of small animals has been developed. The system consists of a noncontact 360°-projection FMT module and a flat panel detector pair based PET module, which are mounted orthogonally for the sake of eliminating cross interference. The FMT images and PET data are simultaneously acquired by employing dynamic sampling mode. Phantom experiments, in which the localization and range of radioactive and fluorescence probes are exactly indicated, have been carried out to verify the feasibility of the system. An experimental tumor-bearing mouse is also scanned using the dual-modality simultaneous imaging system, the preliminary fluorescence tomographic images and PET images demonstrate the in vivo performance of the presented dual-modality system.
Dulski, Kamil; Niedźwiecki, Szymon; Alfs, Dominika; Białas, Piotr; Curceanu, Catalina; Czerwiński, Eryk; Danel, Andrzej; Gajos, Aleksander; Głowacz, Bartosz; Gorgol, Marek; Hiesmayr, Beatrix; Jasińska, Bożena; Kacprzak, Krzysztof; Kamińska, Daria; Kapłon, Łukasz; Kochanowski, Andrzej; Korcyl, Grzegorz; Kowalski, Paweł; Kozik, Tomasz; Krzemień, Wojciech; Kubicz, Ewelina; Kucharek, Mateusz; Mohammed, Muhsin; Pawlik-Niedźwiecka, Monika; Pałka, Marek; Raczyński, Lech; Rudy, Zbigniew; Rundel, Oleksandr; Sharma, Neha G.; Silarski, Michał; Uchacz, Tomasz; Wiślicki, Wojciech; Zgardzińska, Bożena; Zieliński, Marcin; Moskal, Paweł
2017-01-01
A novel plastic scintillator is developed for the application in the digital positron emission tomography (PET). The novelty of the concept lies in application of the 2-(4-styrylphenyl)benzoxazole as a wavelength shifter. The substance has not been used as scintillator dopant before. A dopant shifts the scintillation spectrum towards longer wavelengths making it more suitable for applications in scintillators of long strips geometry and light detection with digital silicon photomultipliers. These features open perspectives for the construction of the cost-effective and MRI-compatible PET scanner with the large field of view. In this article we present the synthesis method and characterize performance of the elaborated scintillator by determining its light emission spectrum, light emission efficiency, rising and decay time of the scintillation pulses and resulting timing resolution when applied in the positron emission tomography. The optimal concentration of the novel wavelength shifter was established by maximizing the light output and it was found to be 0.05 ‰ for cuboidal scintillator with dimensions of 14 mm x 14 mm x 20 mm. PMID:29176834
NASA Astrophysics Data System (ADS)
Salas-García, Irene; Fanjul-Vélez, Félix; Arce-Diego, José Luis
2012-03-01
The development of Photodynamic Therapy (PDT) predictive models has become a valuable tool for an optimal treatment planning, monitoring and dosimetry adjustment. A few attempts have achieved a quite complete characterization of the complex photochemical and photophysical processes involved, even taking into account superficial fluorescence in the target tissue. The present work is devoted to the application of a predictive PDT model to obtain fluorescence tomography information during PDT when applied to a skin disease. The model takes into account the optical radiation distribution, a non-homogeneous topical photosensitizer distribution, the time dependent photochemical interaction and the photosensitizer fluorescence emission. The results show the spatial evolution of the photosensitizer fluorescence emission and the amount of singlet oxygen produced during PDT. The depth dependent photosensitizer fluorescence emission obtained is essential to estimate the spatial photosensitizer concentration and its degradation due to photobleaching. As a consequence the proposed approach could be used to predict the photosensitizer fluorescence tomographic measurements during PDT. The singlet oxygen prediction could also be employed as a valuable tool to predict the short term treatment outcome.
Wieczorek, Anna; Dulski, Kamil; Niedźwiecki, Szymon; Alfs, Dominika; Białas, Piotr; Curceanu, Catalina; Czerwiński, Eryk; Danel, Andrzej; Gajos, Aleksander; Głowacz, Bartosz; Gorgol, Marek; Hiesmayr, Beatrix; Jasińska, Bożena; Kacprzak, Krzysztof; Kamińska, Daria; Kapłon, Łukasz; Kochanowski, Andrzej; Korcyl, Grzegorz; Kowalski, Paweł; Kozik, Tomasz; Krzemień, Wojciech; Kubicz, Ewelina; Kucharek, Mateusz; Mohammed, Muhsin; Pawlik-Niedźwiecka, Monika; Pałka, Marek; Raczyński, Lech; Rudy, Zbigniew; Rundel, Oleksandr; Sharma, Neha G; Silarski, Michał; Uchacz, Tomasz; Wiślicki, Wojciech; Zgardzińska, Bożena; Zieliński, Marcin; Moskal, Paweł
2017-01-01
A novel plastic scintillator is developed for the application in the digital positron emission tomography (PET). The novelty of the concept lies in application of the 2-(4-styrylphenyl)benzoxazole as a wavelength shifter. The substance has not been used as scintillator dopant before. A dopant shifts the scintillation spectrum towards longer wavelengths making it more suitable for applications in scintillators of long strips geometry and light detection with digital silicon photomultipliers. These features open perspectives for the construction of the cost-effective and MRI-compatible PET scanner with the large field of view. In this article we present the synthesis method and characterize performance of the elaborated scintillator by determining its light emission spectrum, light emission efficiency, rising and decay time of the scintillation pulses and resulting timing resolution when applied in the positron emission tomography. The optimal concentration of the novel wavelength shifter was established by maximizing the light output and it was found to be 0.05 ‰ for cuboidal scintillator with dimensions of 14 mm x 14 mm x 20 mm.
Optimization-Based Approach for Joint X-Ray Fluorescence and Transmission Tomographic Inversion
DOE Office of Scientific and Technical Information (OSTI.GOV)
Di, Zichao; Leyffer, Sven; Wild, Stefan M.
2016-01-01
Fluorescence tomographic reconstruction, based on the detection of photons coming from fluorescent emission, can be used for revealing the internal elemental composition of a sample. On the other hand, conventional X-ray transmission tomography can be used for reconstructing the spatial distribution of the absorption coefficient inside a sample. In this work, we integrate both X-ray fluorescence and X-ray transmission data modalities and formulate a nonlinear optimization-based approach for reconstruction of the elemental composition of a given object. This model provides a simultaneous reconstruction of both the quantitative spatial distribution of all elements and the absorption effect in the sample. Mathematicallymore » speaking, we show that compared with the single-modality inversion (i.e., the X-ray transmission or fluorescence alone), the joint inversion provides a better-posed problem, which implies a better recovery. Therefore, the challenges in X-ray fluorescence tomography arising mainly from the effects of self-absorption in the sample are partially mitigated. The use of this technique is demonstrated on the reconstruction of several synthetic samples.« less
J-PET detector system for studies of the electron-positron annihilations
NASA Astrophysics Data System (ADS)
Pawlik-Niedźwiecka, M.; Khreptak, O.; Gajos, A.; Wieczorek, A.; Alfs, D.; Bednarski, T.; Białas, P.; Curceanu, C.; Czerwiński, E.; Dulski, K.; Głowacz, B.; Gupta-Sharma, N.; Gorgol, M.; Hiesmayr, B. C.; Jasińska, B.; Kamińska, D.; Korcyl, G.; Kowalski, P.; Krzmień, W.; Krawczyk, N.; Kubicz, E.; Mohammed, M.; Niedźwiecki, Sz.; Raczyński, L.; Rudy, Z.; Silarski, M.; Wiślicki, W.; Zgardzińska, B.; Zieliński, M.; Moskal, P.
2016-11-01
Jagiellonian Positron Emission Tomograph (J-PET) has been recently constructed at the Jagiellonian University as a prototype of a cost-effective scanner for the metabolic imaging of the whole human body. J-PET detector is optimized for the measurement of momentum and polarization of photons from the electron-positron annihilations. It is built out of strips of plastic scintillators, forming three cylindrical layers. As detector of gamma quanta it will be used for studies of discrete symmetries and multiparticle entanglement of photons originating from the decays of ortho-positronium atoms.
Angelis, G I; Reader, A J; Markiewicz, P J; Kotasidis, F A; Lionheart, W R; Matthews, J C
2013-08-07
Recent studies have demonstrated the benefits of a resolution model within iterative reconstruction algorithms in an attempt to account for effects that degrade the spatial resolution of the reconstructed images. However, these algorithms suffer from slower convergence rates, compared to algorithms where no resolution model is used, due to the additional need to solve an image deconvolution problem. In this paper, a recently proposed algorithm, which decouples the tomographic and image deconvolution problems within an image-based expectation maximization (EM) framework, was evaluated. This separation is convenient, because more computational effort can be placed on the image deconvolution problem and therefore accelerate convergence. Since the computational cost of solving the image deconvolution problem is relatively small, multiple image-based EM iterations do not significantly increase the overall reconstruction time. The proposed algorithm was evaluated using 2D simulations, as well as measured 3D data acquired on the high-resolution research tomograph. Results showed that bias reduction can be accelerated by interleaving multiple iterations of the image-based EM algorithm solving the resolution model problem, with a single EM iteration solving the tomographic problem. Significant improvements were observed particularly for voxels that were located on the boundaries between regions of high contrast within the object being imaged and for small regions of interest, where resolution recovery is usually more challenging. Minor differences were observed using the proposed nested algorithm, compared to the single iteration normally performed, when an optimal number of iterations are performed for each algorithm. However, using the proposed nested approach convergence is significantly accelerated enabling reconstruction using far fewer tomographic iterations (up to 70% fewer iterations for small regions). Nevertheless, the optimal number of nested image-based EM iterations is hard to be defined and it should be selected according to the given application.
Keles, Papatya; Yuce, Ihsan; Keles, Sait; Kantarci, Mecit
2016-06-01
The aim of this study was to define the different courses and percentages of hepatic artery that were detected during preoperative evaluation of living liver donors by multidetector computed tomographic angiography (MDCTA). We evaluated 150 donors before hepatic transplantation. All of the donors were evaluated by multislice CT scan with 256 detectors. For each patient, arterial, portal and venous phase images were obtained. The hepatic arterial variations were evaluated by the same radiologist according to Michels' classification. Common hepatic arterial anatomy (type I) was observed in 95 donors (63.3%). Other arterial variations were determined in the remaining 55 donors (36.6%). The second common variation was type XI which did not match with the description of Michels' classification variation in 15 donors (10%). The remaining variations described in Michels' classification were seen at lower rates. Type VII or X variation was not seen. MDCTA is a useful method to identify the blood supply of the liver before the liver transplantations, and surgeons can make their plan on the basis of CT data.
IDIOS: An innovative index for evaluating dental imaging-based osteoporosis screening indices
Halboub, Esam; Almashraqi, Abeer Abdulkareem; Khattab, Razan; Al Haffar, Iyad
2016-01-01
Purpose The goal of this study was to develop a new index as an objective reference for evaluating current and newly developed indices used for osteoporosis screening based on dental images. Its name; IDIOS, stands for Index of Dental-imaging Indices of Osteoporosis Screening. Materials and Methods A comprehensive PubMed search was conducted to retrieve studies on dental imaging-based indices for osteoporosis screening. The results of the eligible studies, along with other relevant criteria, were used to develop IDIOS, which has scores ranging from 0 (0%) to 15 (100%). The indices presented in the studies we included were then evaluated using IDIOS. Results The 104 studies that were included utilized 24, 4, and 9 indices derived from panoramic, periapical, and computed tomographic/cone-beam computed tomographic techniques, respectively. The IDIOS scores for these indices ranged from 0 (0%) to 11.75 (78.32%). Conclusion IDIOS is a valuable reference index that facilitates the evaluation of other dental imaging-based osteoporosis screening indices. Furthermore, IDIOS can be utilized to evaluate the accuracy of newly developed indices. PMID:27672615
Trace: a high-throughput tomographic reconstruction engine for large-scale datasets
Bicer, Tekin; Gursoy, Doga; Andrade, Vincent De; ...
2017-01-28
Here, synchrotron light source and detector technologies enable scientists to perform advanced experiments. These scientific instruments and experiments produce data at such scale and complexity that large-scale computation is required to unleash their full power. One of the widely used data acquisition technique at light sources is Computed Tomography, which can generate tens of GB/s depending on x-ray range. A large-scale tomographic dataset, such as mouse brain, may require hours of computation time with a medium size workstation. In this paper, we present Trace, a data-intensive computing middleware we developed for implementation and parallelization of iterative tomographic reconstruction algorithms. Tracemore » provides fine-grained reconstruction of tomography datasets using both (thread level) shared memory and (process level) distributed memory parallelization. Trace utilizes a special data structure called replicated reconstruction object to maximize application performance. We also present the optimizations we have done on the replicated reconstruction objects and evaluate them using a shale and a mouse brain sinogram. Our experimental evaluations show that the applied optimizations and parallelization techniques can provide 158x speedup (using 32 compute nodes) over single core configuration, which decreases the reconstruction time of a sinogram (with 4501 projections and 22400 detector resolution) from 12.5 hours to less than 5 minutes per iteration.« less
Widmer, W R; Buckwalter, K A; Fessler, J F; Hill, M A; VanSickle, D C; Ivancevich, S
2000-01-01
Radiographic evaluation of navicular syndrome is problematic because of its inconsistent correlation with clinical signs. Scintigraphy often yields false positive and false negative results and diagnostic ultrasound is of limited value. Therefore, we assessed the use of computed tomography and magnetic resonance imaging in a horse with clinical and radiographic signs of navicular syndrome. Cadaver specimens were examined with spiral computed tomographic and high-field magnetic resonance scanners and images were correlated with pathologic findings. Radiographic changes consisted of bony remodeling, which included altered synovial fossae, increased medullary opacity, cyst formation and shape change. These osseous changes were more striking and more numerous on computed tomographic and magnetic resonance images. They were most clearly defined with computed tomography. Many osseous changes seen with computed tomography and magnetic resonance imaging were not radiographically evident. Histologically confirmed soft tissue alterations of the deep digital flexor tendon, impar ligament and marrow were identified with magnetic resonance imaging, but not with conventional radiography. Because of their multiplanar capability and tomographic nature, computed tomography and magnetic resonance imaging surpass conventional radiography for navicular imaging, facilitating earlier, more accurate diagnosis. Current advances in imaging technology should make these imaging modalities available to equine practitioners in the future.
Trace: a high-throughput tomographic reconstruction engine for large-scale datasets
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bicer, Tekin; Gursoy, Doga; Andrade, Vincent De
Here, synchrotron light source and detector technologies enable scientists to perform advanced experiments. These scientific instruments and experiments produce data at such scale and complexity that large-scale computation is required to unleash their full power. One of the widely used data acquisition technique at light sources is Computed Tomography, which can generate tens of GB/s depending on x-ray range. A large-scale tomographic dataset, such as mouse brain, may require hours of computation time with a medium size workstation. In this paper, we present Trace, a data-intensive computing middleware we developed for implementation and parallelization of iterative tomographic reconstruction algorithms. Tracemore » provides fine-grained reconstruction of tomography datasets using both (thread level) shared memory and (process level) distributed memory parallelization. Trace utilizes a special data structure called replicated reconstruction object to maximize application performance. We also present the optimizations we have done on the replicated reconstruction objects and evaluate them using a shale and a mouse brain sinogram. Our experimental evaluations show that the applied optimizations and parallelization techniques can provide 158x speedup (using 32 compute nodes) over single core configuration, which decreases the reconstruction time of a sinogram (with 4501 projections and 22400 detector resolution) from 12.5 hours to less than 5 minutes per iteration.« less
Longo, Maurizio; Andreis, Maria Elena; Pettinato, Cinzia; Ravasio, Giuliano; Rabbogliatti, Vanessa; De Zani, Donatella; Di Giancamillo, Mauro; Zani, Davide Danilo
2016-03-29
The aim of the work is the application of a bolus tracking technique for tomographic evaluation of the uretero-vesicular junction in dogs. Ten adult dogs (8-14 years) with variable body weight (2,8-32 kg) were enrolled in the prospective study. The patients were placed in sternal recumbency with a 10° elevated pelvis and the visualization of the uretero-vesicular junction was obtained with the bolus tracking technique after intravenous administration of non-ionic contrast medium. In the post-contrast late phase a region of interest was placed within the lumen of the distal ureters and the density values were monitored before starting the helical scan. The uretero-vesicular junction was clearly visible in 100% of patients with the visualization of the endoluminal ureteral contrast enhancement and bladder washout. At the end of the tomographic study an evaluation of the dose records was performed and compared to human exposures reported in literature for the pelvic region. The effective dose estimated for each patient (37,5-138 mSv) proved to be elevated, when compared to those reported in human patients. The bolus tracking technique could be applied for the visualization of the uretero-vesicular junction in non-pathological patients, placing the region of interest in the distal ureters. The high effective doses recorded in our study support the need of specific thresholds for veterinary patients, pointing out the attention for paediatric patient's exposure also in veterinary imaging.
Evaluation of effective dose with chest digital tomosynthesis system using Monte Carlo simulation
NASA Astrophysics Data System (ADS)
Kim, Dohyeon; Jo, Byungdu; Lee, Youngjin; Park, Su-Jin; Lee, Dong-Hoon; Kim, Hee-Joung
2015-03-01
Chest digital tomosynthesis (CDT) system has recently been introduced and studied. This system offers the potential to be a substantial improvement over conventional chest radiography for the lung nodule detection and reduces the radiation dose with limited angles. PC-based Monte Carlo program (PCXMC) simulation toolkit (STUK, Helsinki, Finland) is widely used to evaluate radiation dose in CDT system. However, this toolkit has two significant limits. Although PCXMC is not possible to describe a model for every individual patient and does not describe the accurate X-ray beam spectrum, Geant4 Application for Tomographic Emission (GATE) simulation describes the various size of phantom for individual patient and proper X-ray spectrum. However, few studies have been conducted to evaluate effective dose in CDT system with the Monte Carlo simulation toolkit using GATE. The purpose of this study was to evaluate effective dose in virtual infant chest phantom of posterior-anterior (PA) view in CDT system using GATE simulation. We obtained the effective dose at different tube angles by applying dose actor function in GATE simulation which was commonly used to obtain the medical radiation dosimetry. The results indicated that GATE simulation was useful to estimate distribution of absorbed dose. Consequently, we obtained the acceptable distribution of effective dose at each projection. These results indicated that GATE simulation can be alternative method of calculating effective dose in CDT applications.
Enhanced Combined Tomography and Biomechanics Data for Distinguishing Forme Fruste Keratoconus.
Luz, Allan; Lopes, Bernardo; Hallahan, Katie M; Valbon, Bruno; Ramos, Isaac; Faria-Correia, Fernando; Schor, Paulo; Dupps, William J; Ambrósio, Renato
2016-07-01
To evaluate the performance of the Ocular Response Analyzer (ORA) (Reichert Ophthalmic Instruments, Depew, NY) variables and Pentacam HR (Oculus Optikgeräte GmbH, Wetzlar, Germany) tomographic parameters in differentiating forme fruste keratoconus (FFKC) from normal corneas, and to assess a combined biomechanical and tomographic parameter to improve outcomes. Seventy-six eyes of 76 normal patients and 21 eyes of 21 patients with FFKC were included in the study. Fifteen variables were derived from exported ORA signals to characterize putative indicators of biomechanical behavior and 37 ORA waveform parameters were tested. Sixteen tomographic parameters from Pentacam HR were tested. Logistic regression was used to produce a combined biomechanical and tomography linear model. Differences between groups were assessed by the Mann-Whitney U test. The area under the receiver operating characteristics curve (AUROC) was used to compare diagnostic performance. No statistically significant differences were found in age, thinnest point, central corneal thickness, and maximum keratometry between groups. Twenty-one parameters showed significant differences between the FFKC and control groups. Among the ORA waveform measurements, the best parameters were those related to the area under the first peak, p1area1 (AUROC, 0.717 ± 0.065). Among the investigator ORA variables, a measure incorporating the pressure-deformation relationship of the entire response cycle was the best predictor (hysteresis loop area, AUROC, 0.688 ± 0.068). Among tomographic parameters, Belin/Ambrósio display showed the highest predictive value (AUROC, 0.91 ± 0.057). A combination of parameters showed the best result (AUROC, 0.953 ± 0.024) outperforming individual parameters. Tomographic and biomechanical parameters demonstrated the ability to differentiate FFKC from normal eyes. A combination of both types of information further improved predictive value. [J Refract Surg. 2016;32(7):479-485.]. Copyright 2016, SLACK Incorporated.
Acoustic emission characterization of microcracking in laboratory-scale hydraulic fracturing tests
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hampton, Jesse; Gutierrez, Marte; Matzar, Luis
Understanding microcracking near coalesced fracture generation is critically important for hydrocarbon and geothermal reservoir characterization as well as damage evaluation in civil engineering structures. Dense and sometimes random microcracking near coalesced fracture formation alters the mechanical properties of the nearby virgin material. Individual microcrack characterization is also significant in quantifying the material changes near the fracture faces (i.e. damage). Acoustic emission (AE) monitoring and analysis provide unique information regarding the microcracking process temporally, and information concerning the source characterization of individual microcracks can be extracted. In this context, laboratory hydraulic fracture tests were carried out while monitoring the AEs frommore » several piezoelectric transducers. In-depth post-processing of the AE event data was performed for the purpose of understanding the individual source mechanisms. Several source characterization techniques including moment tensor inversion, event parametric analysis, and volumetric deformation analysis were adopted. Post-test fracture characterization through coring, slicing and micro-computed tomographic imaging was performed to determine the coalesced fracture location and structure. Distinct differences in fracture characteristics were found spatially in relation to the openhole injection interval. Individual microcrack AE analysis showed substantial energy reduction emanating spatially from the injection interval. Lastly, it was quantitatively observed that the recorded AE signals provided sufficient information to generalize the damage radiating spatially away from the injection wellbore.« less
Characterization of the LBNL PEM Camera
NASA Astrophysics Data System (ADS)
Wang, G.-C.; Huber, J. S.; Moses, W. W.; Qi, J.; Choong, W.-S.
2006-06-01
We present the tomographic images and performance measurements of the LBNL positron emission mammography (PEM) camera, a specially designed positron emission tomography (PET) camera that utilizes PET detector modules with depth of interaction measurement capability to achieve both high sensitivity and high resolution for breast cancer detection. The camera currently consists of 24 detector modules positioned as four detector banks to cover a rectangular patient port that is 8.2/spl times/6 cm/sup 2/ with a 5 cm axial extent. Each LBNL PEM detector module consists of 64 3/spl times/3/spl times/30 mm/sup 3/ LSO crystals coupled to a single photomultiplier tube (PMT) and an 8/spl times/8 silicon photodiode array (PD). The PMT provides accurate timing, the PD identifies the crystal of interaction, the sum of the PD and PMT signals (PD+PMT) provides the total energy, and the PD/(PD+PMT) ratio determines the depth of interaction. The performance of the camera has been evaluated by imaging various phantoms. The full-width-at-half-maximum (FWHM) spatial resolution changes slightly from 1.9 mm to 2.1 mm when measured at the center and corner of the field of the view, respectively, using a 6 ns coincidence timing window and a 300-750 keV energy window. With the same setup, the peak sensitivity of the camera is 1.83 kcps//spl mu/Ci.
Acoustic emission characterization of microcracking in laboratory-scale hydraulic fracturing tests
Hampton, Jesse; Gutierrez, Marte; Matzar, Luis; ...
2018-06-11
Understanding microcracking near coalesced fracture generation is critically important for hydrocarbon and geothermal reservoir characterization as well as damage evaluation in civil engineering structures. Dense and sometimes random microcracking near coalesced fracture formation alters the mechanical properties of the nearby virgin material. Individual microcrack characterization is also significant in quantifying the material changes near the fracture faces (i.e. damage). Acoustic emission (AE) monitoring and analysis provide unique information regarding the microcracking process temporally, and information concerning the source characterization of individual microcracks can be extracted. In this context, laboratory hydraulic fracture tests were carried out while monitoring the AEs frommore » several piezoelectric transducers. In-depth post-processing of the AE event data was performed for the purpose of understanding the individual source mechanisms. Several source characterization techniques including moment tensor inversion, event parametric analysis, and volumetric deformation analysis were adopted. Post-test fracture characterization through coring, slicing and micro-computed tomographic imaging was performed to determine the coalesced fracture location and structure. Distinct differences in fracture characteristics were found spatially in relation to the openhole injection interval. Individual microcrack AE analysis showed substantial energy reduction emanating spatially from the injection interval. Lastly, it was quantitatively observed that the recorded AE signals provided sufficient information to generalize the damage radiating spatially away from the injection wellbore.« less
Effects of lithium on brain glucose metabolism in healthy men.
Kohno, Tomoya; Shiga, Tohru; Toyomaki, Atsuhito; Kusumi, Ichiro; Matsuyama, Tetsuaki; Inoue, Tetsuya; Katoh, Chietsugu; Koyama, Tsukasa; Tamaki, Nagara
2007-12-01
Lithium is clinically available for the treatment of mood disorders. However, it has remained unclear how lithium acts on the brain to produce its effects. The aim of this study was to evaluate the effects of chronic lithium on human brain activity using positron emission tomography and clarify the correlation between brain activity changes and cognitive functional changes as induced by chronic lithium administration. A total of 20 healthy male subjects (mean age, 32 +/- 6 years) underwent positron emission tomographic scans with F-fluorodeoxyglucose and a battery of neuropsychological tests at baseline condition and after 4 weeks of lithium administration. Brain metabolic data were analyzed using statistical parametric mapping. Lithium increased relative regional cerebral glucose metabolism (rCMRglc) in the bilateral dorsomedial frontal cortices including the anterior cingulate gyrus and decreased rCMRglc in the right cerebellum and left lingual gyrus/cuneus. There was no difference in any of the variables of cognitive functions between the baseline condition and after chronic lithium administration. There was no correlation between rCMRglc changes in any of the brain regions and individual variable changes in any of the neuropsychological tests. The results suggest that the effects of chronic lithium are associated with increased activity in the bilateral dorsomedial frontal cortices including the anterior cingulate gyrus and decreased activity in the right cerebellum and left lingual gyrus/cuneus.
Delso, Gaspar; Khalighi, Mohammed; Ter Voert, Edwin; Barbosa, Felipe; Sekine, Tetsuro; Hüllner, Martin; Veit-Haibach, Patrick
2017-01-01
Purpose To evaluate the magnitude and anatomic extent of the artifacts introduced on positron emission tomographic (PET)/magnetic resonance (MR) images by respiratory state mismatch in the attenuation map. Materials and Methods The method was tested on 14 patients referred for an oncologic examination who underwent PET/MR imaging. The acquisition included standard PET and MR series for each patient, and an additional attenuation correction series was acquired by using breath hold. PET data were reconstructed with and without time-of-flight (TOF) information, first by using the standard free-breathing attenuation map and then again by using the additional breath-hold map. Two-tailed paired t testing and linear regression with 0 intercept was performed on TOF versus non-TOF and free-breathing versus breath-hold data for all detected lesions. Results Fluorodeoxyglucose-avid lesions were found in eight of the 14 patients included in the study. The uptake differences (maximum standardized uptake values) between PET reconstructions with free-breathing versus breath-hold attenuation ranged, for non-TOF reconstructions, from -18% to 26%. The corresponding TOF reconstructions yielded differences from -15% to 18%. Conclusion TOF information was shown to reduce the artifacts caused at PET/MR by respiratory mismatch between emission and attenuation data. © RSNA, 2016 Online supplemental material is available for this article.
Häggström, Ida; Beattie, Bradley J; Schmidtlein, C Ross
2016-06-01
To develop and evaluate a fast and simple tool called dpetstep (Dynamic PET Simulator of Tracers via Emission Projection), for dynamic PET simulations as an alternative to Monte Carlo (MC), useful for educational purposes and evaluation of the effects of the clinical environment, postprocessing choices, etc., on dynamic and parametric images. The tool was developed in matlab using both new and previously reported modules of petstep (PET Simulator of Tracers via Emission Projection). Time activity curves are generated for each voxel of the input parametric image, whereby effects of imaging system blurring, counting noise, scatters, randoms, and attenuation are simulated for each frame. Each frame is then reconstructed into images according to the user specified method, settings, and corrections. Reconstructed images were compared to MC data, and simple Gaussian noised time activity curves (GAUSS). dpetstep was 8000 times faster than MC. Dynamic images from dpetstep had a root mean square error that was within 4% on average of that of MC images, whereas the GAUSS images were within 11%. The average bias in dpetstep and MC images was the same, while GAUSS differed by 3% points. Noise profiles in dpetstep images conformed well to MC images, confirmed visually by scatter plot histograms, and statistically by tumor region of interest histogram comparisons that showed no significant differences (p < 0.01). Compared to GAUSS, dpetstep images and noise properties agreed better with MC. The authors have developed a fast and easy one-stop solution for simulations of dynamic PET and parametric images, and demonstrated that it generates both images and subsequent parametric images with very similar noise properties to those of MC images, in a fraction of the time. They believe dpetstep to be very useful for generating fast, simple, and realistic results, however since it uses simple scatter and random models it may not be suitable for studies investigating these phenomena. dpetstep can be downloaded free of cost from https://github.com/CRossSchmidtlein/dPETSTEP.
Chen, Lih-Shyang; Hsu, Ta-Wen; Chang, Shu-Han; Lin, Chih-Wen; Chen, Yu-Ruei; Hsieh, Chin-Chiang; Han, Shu-Chen; Chang, Ku-Yaw; Hou, Chun-Ju
2017-01-01
Objective: In traditional surface rendering (SR) computed tomographic endoscopy, only the shape of endoluminal lesion is depicted without gray-level information unless the volume rendering technique is used. However, volume rendering technique is relatively slow and complex in terms of computation time and parameter setting. We use computed tomographic colonography (CTC) images as examples and report a new visualization technique by three-dimensional gray level mapping (GM) to better identify and differentiate endoluminal lesions. Methods: There are 33 various endoluminal cases from 30 patients evaluated in this clinical study. These cases were segmented using gray-level threshold. The marching cube algorithm was used to detect isosurfaces in volumetric data sets. GM is applied using the surface gray level of CTC. Radiologists conducted the clinical evaluation of the SR and GM images. The Wilcoxon signed-rank test was used for data analysis. Results: Clinical evaluation confirms GM is significantly superior to SR in terms of gray-level pattern and spatial shape presentation of endoluminal cases (p < 0.01) and improves the confidence of identification and clinical classification of endoluminal lesions significantly (p < 0.01). The specificity and diagnostic accuracy of GM is significantly better than those of SR in diagnostic performance evaluation (p < 0.01). Conclusion: GM can reduce confusion in three-dimensional CTC and well correlate CTC with sectional images by the location as well as gray-level value. Hence, GM increases identification and differentiation of endoluminal lesions, and facilitates diagnostic process. Advances in knowledge: GM significantly improves the traditional SR method by providing reliable gray-level information for the surface points and is helpful in identification and differentiation of endoluminal lesions according to their shape and density. PMID:27925483
Results of the National CT Colonography Trial: Questions and Answers
Learn the results of the National Computerized Tomographic Colonography (CTC) clinical trial, which evaluated how well CTC identifies participants with at least one significantly large polyp using colonoscopy as the gold (or reference) standard.
Optical tomographic detection of rheumatoid arthritis with computer-aided classification schemes
NASA Astrophysics Data System (ADS)
Klose, Christian D.; Klose, Alexander D.; Netz, Uwe; Beuthan, Jürgen; Hielscher, Andreas H.
2009-02-01
A recent research study has shown that combining multiple parameters, drawn from optical tomographic images, leads to better classification results to identifying human finger joints that are affected or not affected by rheumatic arthritis RA. Building up on the research findings of the previous study, this article presents an advanced computer-aided classification approach for interpreting optical image data to detect RA in finger joints. Additional data are used including, for example, maximum and minimum values of the absorption coefficient as well as their ratios and image variances. Classification performances obtained by the proposed method were evaluated in terms of sensitivity, specificity, Youden index and area under the curve AUC. Results were compared to different benchmarks ("gold standard"): magnet resonance, ultrasound and clinical evaluation. Maximum accuracies (AUC=0.88) were reached when combining minimum/maximum-ratios and image variances and using ultrasound as gold standard.
Can macrocirculation changes predict nonhealing diabetic foot ulcers?
Lee, Ye-Na; Kim, Hyon-Surk; Kang, Jeong-A; Han, Seung-Kyu
2014-01-01
Transcutaneous partial oxygen tension (TcpO2) is considered the gold standard for assessment of tissue oxygenation, which is an essential factor for wound healing. The purpose of this study was to evaluate the association between macrocirculation and TcpO2 in persons with diabetes mellitus. Ninety-eight patients with diabetic foot ulcers participated in the study (61 men and 37 women). The subjects had a mean age of 66.6 years (range, 30-83 years) and were treated at the Diabetic Wound Center of Korea University Guro Hospital, Seoul, Republic of Korea. Macrocirculation was evaluated using 2 techniques: computed tomographic angiography and Doppler ultrasound. Macrocirculation scores were based on the patency of the two tibial arteries in 98 patients. Computed tomographic angiography and Doppler ultrasound scores (0-4 points) were given according to intraluminal filling defects and arterial pulse waveform of each vessel, respectively. Tissue oxygenation was measured by TcpO2. Macrocirculation scores were statistically analyzed as a function of the TcpO2. Statistical analysis revealed no significant linear trend between the macrocirculation status and TcpO2. Biavariate analysis using the Fisher exact test, Mantel-Haenszel tests, and McNemar-Bowker tests also found no significant relationship between macrocirculation and TcpO2. Computed tomographic angiography and Doppler ultrasound are not sufficiently reliable substitutes for TcpO2 measurements in regard to determining the optimal treatment for diabetic patients.
NASA Astrophysics Data System (ADS)
Seidel, Anne; Wagner, Steven; Dreizler, Andreas; Ebert, Volker
2014-05-01
One of the most intricate effects in climate modelling is the role of permafrost thawing during the global warming process. Soil that has formerly never totally lost its ice cover now emits climate gases due to melting processes[1]. For a better prediction of climate development and possible feedback mechanisms, insights into physical procedures (like e.g. gas emission from underground reservoirs) are required[2]. Therefore, a long-term quantification of greenhouse gas concentrations (and further on fluxes) is necessary and the related structures that are responsible for emission need to be identified. In particular the spatial heterogeneity of soils caused by soil internal structures (e.g. soil composition changes or surface cracks) or by surface modifications (e.g. by plant growth) generate considerable complexities and difficulties for local measurements, for example with soil chambers. For such situations, which often cannot be avoided, a spatially resolved 2D-measurement to identify and quantify the gas emission from the structured soil would be needed, to better understand the influence of the soil sub-structures on the emission behavior. Thus we designed a spatially scanning laser absorption spectrometer setup to determine a 2D-gas concentration map in the soil-air boundary layer. The setup is designed to cover the surfaces in the range of square meters in a horizontal plane above the soil to be investigated. Existing field instruments for gas concentration or flux measurements are based on point-wise measurements, so structure identification is very tedious or even impossible. For this reason, we have developed a tomographic in-situ instrument based on TDLAS ('tunable diode laser absorption spectroscopy') that delivers absolute gas concentration distributions of areas with 0.8m × 0.8m size, without any need for reference measurements with a calibration gas. It is a simple and robust device based on a combination of scanning mirrors and reflecting foils, so that only very little optical alignment is necessary in the field. The measurement rate for a complete 2D field is presently up to 2.5 Hz. The measurement field size is currently limited only by laboratory conditions and could be extended easily to the range of several meters, as previous tests have confirmed[3]. A fast laser tuning rate of more than 5 kHz leads to high measurement path density, and overall more than 70% of a square shaped field area is covered. With this instrument, measurements of H2O- and CH4 - concentration distributions have taken place so far. We are going to discuss the instrument setup and the spectroscopic performance and present numerical studies concerning the tomographic reconstruction quality as well as first 2D reconstructions in the laboratory. The applicability to 2D CO2 detection and the improvement of frame rate and reconstruction quality using faster laser tuning will be discussed. [1] K. M. Walter Anthony, P. Anthony, G. Grosse, and J. Chanton, 'Geologic methane seeps along boundaries of Arctic permafrost thaw and melting glaciers,' Nat. Geosci., vol. 5, no. 6, pp. 419-426, May 2012. [2] B. Elberling, A. Michelsen, C. Schädel, E. A. G. Schuur, H. H. Christiansen, L. Tamstorf, M. P. Berg, and C. Sigsgaard, 'Long-term CO2 production following permafrost thaw,' Nat. Clim. Chang., vol. 3, no. 10, pp. 890-894, 2013. [3] A. Seidel, S. Wagner, and V. Ebert, 'TDLAS-based open-path laser hygrometer using simple reflective foils as scattering targets,' Appl. Phys. B, vol. 109, no. 3, pp. 497-504, Oct. 2012.
NASA Astrophysics Data System (ADS)
Santos-Costa, D.; Bolton, S. J.; Adumitroaie, V.; Janssen, M.; Levin, S.; Sault, R. J.; De Pater, I.; Tao, C.
2015-12-01
The Juno spacecraft will go into polar orbit after it arrives at Jupiter in mid-2016. Between November 2016 and March 2017, six MicroWave Radiometers will collect information on Jupiter's atmosphere and electron belt. Here we present simulations of MWR observations of the electron belt synchrotron emission, and discuss the features and dynamical behavior of this emission when observations are carried out from inside the radiation zone. We first present our computation method. We combine a three-dimensional tomographic reconstruction method of Earth-based observations and a theoretical model of Jupiter's electron belt to constrain the calculations of the volume emissivity of the synchrotron radiation for any frequency, location in the Jovian inner magnetosphere (radial distance < 4 Rj), and observational direction. Values of the computed emissivity are incorporated into a synchrotron simulator to predict Juno MWR measurements (full sky maps and temperatures) at any time of the mission. Samples of simulated MWR observations are presented and examined for different segments of Juno trajectory. We also present results of our ongoing investigation of the radiation zone distribution around the planet and the sources of variation on different time-scales. We show that a better understanding of the spatial distribution and variability of the electron belt is key to realistically forecast Juno MWR measurements.
Prospective radiographic followup after en bloc ligation of the renal hilum.
White, Wesley M; Klein, Frederick A; Gash, Judson; Waters, W Bedford
2007-11-01
We determined the risk of arteriovenous fistula after en bloc ligation of the renal hilum. A prospective evaluation of all patients who underwent en bloc ligation of the renal hilum during nephrectomy for malignant disease was performed. Pertinent operative data were recorded and patients were followed for clinical evidence of arteriovenous fistula formation, including hypertension, abdominal bruit and new onset congestive heart failure. Patients with at least 12 months of followup underwent computerized tomographic arteriography to assess arteriovenous fistula formation. A total of 94 patients underwent en bloc renal hilar ligation during open (43) and laparoscopic (51) nephrectomy using a 45 mm titanium endovascular stapler. Of this cohort 11 patients were lost to followup and 3 died of disease. The remaining 80 patients were followed an average of 35.2 months with no clinical evidence of arteriovenous fistula formation. Specifically there was no statistically significant difference in preoperative and postoperative blood pressure (p = 0.18 and 0.62, respectively), no evidence of abdominal bruit on examination and no new onset congestive heart failure. A total of 32 had increased serum creatinine and, therefore, they were excluded from followup computerized tomographic arteriography. Eight patients had a followup of less than 1 year and they were not yet eligible for evaluation. In the 40 patients who underwent computerized tomographic arteriography no fistulas were noted. Based on clinical followup and prospective radiographic evaluation there appears to be a low risk of arteriovenous fistula formation after en bloc ligation of the renal hilum using a titanium endovascular stapler.
Intravascular lymphomatosis presenting as acute hemispheric dysfunction.
Hwang, Woo Sub; Jung, Chul Won; Ko, Young Hye; Seo, Sang Won; Na, Duk L
2012-11-01
Intravascular lymphomatosis (IVL) is known to affect both hemispheres of the brain and manifests clinically as seizures or dementia. To our knowledge, there have been no cases in which acute hemispheric dysfunction is manifested in IVL. We present a 54-year-old man who showed steroid responsive acute hemispheric dysfunction. A technetium 99m-ethyl cysteinate dimer single-photon emission computed tomographic scan of the brain revealed hypoperfusion in the right hemisphere. The bone marrow biopsy specimen confirmed malignant lymphoid cells in vessels, which suggested IVL. Our case signifies the diversity of clinical manifestations in IVL. Copyright © 2012. Published by Elsevier Inc.
A new art code for tomographic interferometry
NASA Technical Reports Server (NTRS)
Tan, H.; Modarress, D.
1987-01-01
A new algebraic reconstruction technique (ART) code based on the iterative refinement method of least squares solution for tomographic reconstruction is presented. Accuracy and the convergence of the technique is evaluated through the application of numerically generated interferometric data. It was found that, in general, the accuracy of the results was superior to other reported techniques. The iterative method unconditionally converged to a solution for which the residual was minimum. The effects of increased data were studied. The inversion error was found to be a function of the input data error only. The convergence rate, on the other hand, was affected by all three parameters. Finally, the technique was applied to experimental data, and the results are reported.
Banzato, T; Selleri, P; Veladiano, I A; Zotti, A
2013-12-01
Contrast-enhanced computed tomographic studies of the coelomic cavity in four green iguanas, four black and white tegus and four bearded dragons were performed using a conventional CT scanner. Anatomical reference cross sections were obtained from four green iguana, four black and white tegu and six bearded dragon cadavers; the specimens were stored in a -20°C freezer for 24 h then sliced into 5-mm intervals. The frozen sections were cleaned with water and photographed on both sides. The individual anatomical structures were identified by means of the available literature; these were labelled first on the anatomical images and then matched to the corresponding computed tomography images. The results provide an atlas of the normal cross-sectional and computed tomographic anatomy of the coelomic cavity in the green iguana, the black and white tegu and the bearded dragon, which is useful in the interpretation of any imaging modality. © 2013 Blackwell Verlag GmbH.
Towards Omni-Tomography—Grand Fusion of Multiple Modalities for Simultaneous Interior Tomography
Wang, Ge; Zhang, Jie; Gao, Hao; Weir, Victor; Yu, Hengyong; Cong, Wenxiang; Xu, Xiaochen; Shen, Haiou; Bennett, James; Furth, Mark; Wang, Yue; Vannier, Michael
2012-01-01
We recently elevated interior tomography from its origin in computed tomography (CT) to a general tomographic principle, and proved its validity for other tomographic modalities including SPECT, MRI, and others. Here we propose “omni-tomography”, a novel concept for the grand fusion of multiple tomographic modalities for simultaneous data acquisition in a region of interest (ROI). Omni-tomography can be instrumental when physiological processes under investigation are multi-dimensional, multi-scale, multi-temporal and multi-parametric. Both preclinical and clinical studies now depend on in vivo tomography, often requiring separate evaluations by different imaging modalities. Over the past decade, two approaches have been used for multimodality fusion: Software based image registration and hybrid scanners such as PET-CT, PET-MRI, and SPECT-CT among others. While there are intrinsic limitations with both approaches, the main obstacle to the seamless fusion of multiple imaging modalities has been the bulkiness of each individual imager and the conflict of their physical (especially spatial) requirements. To address this challenge, omni-tomography is now unveiled as an emerging direction for biomedical imaging and systems biomedicine. PMID:22768108
Design and initial performance of PlanTIS: a high-resolution positron emission tomograph for plants
NASA Astrophysics Data System (ADS)
Beer, S.; Streun, M.; Hombach, T.; Buehler, J.; Jahnke, S.; Khodaverdi, M.; Larue, H.; Minwuyelet, S.; Parl, C.; Roeb, G.; Schurr, U.; Ziemons, K.
2010-02-01
Positron emitters such as 11C, 13N and 18F and their labelled compounds are widely used in clinical diagnosis and animal studies, but can also be used to study metabolic and physiological functions in plants dynamically and in vivo. A very particular tracer molecule is 11CO2 since it can be applied to a leaf as a gas. We have developed a Plant Tomographic Imaging System (PlanTIS), a high-resolution PET scanner for plant studies. Detectors, front-end electronics and data acquisition architecture of the scanner are based on the ClearPET™ system. The detectors consist of LSO and LuYAP crystals in phoswich configuration which are coupled to position-sensitive photomultiplier tubes. Signals are continuously sampled by free running ADCs, and data are stored in a list mode format. The detectors are arranged in a horizontal plane to allow the plants to be measured in the natural upright position. Two groups of four detector modules stand face-to-face and rotate around the field-of-view. This special system geometry requires dedicated image reconstruction and normalization procedures. We present the initial performance of the detector system and first phantom and plant measurements.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lassen, N.A.; Henriksen, L.; Holm, S.
1983-01-01
Tomographic maps of local cerebral blood flow (CBF) were obtained with xenon-133 and with isopropyl-amphetamine-iodine-123 (IMP) in 11 subjects: one normal, two tumor cases, and eight cerebrovascular cases. A highly sensitive four-face, rapidly rotating, single-photon emission tomograph was used. The Xe-133 flow maps are essentially based on the average Xe-133 concentration over the initial 2 min during and after an inhalation of the inert gas lasting 1 min. These maps agreed very well with the early IMP maps obtained over the initial 10 min following an i.v. bolus injection. The subsequent IMP tomograms showed a slight decrease in contrast amountingmore » to appr. five percentage points in the CBF ratio between diseased and contralateral areas. It is concluded that Xe-133 is more practical: low cost, available on a 7-day basis, easily repeatable, quantifiable without the need for arterial sampling, and with low radiation exposure to patient and personnel. On the other hand, IMP gives an image of slightly higher resolution. It also introduces a new class of iodinated brain-seeking compounds allowing, perhaps, imaging of other functions more important than mere blood flow.« less
Design and initial performance of PlanTIS: a high-resolution positron emission tomograph for plants.
Beer, S; Streun, M; Hombach, T; Buehler, J; Jahnke, S; Khodaverdi, M; Larue, H; Minwuyelet, S; Parl, C; Roeb, G; Schurr, U; Ziemons, K
2010-02-07
Positron emitters such as (11)C, (13)N and (18)F and their labelled compounds are widely used in clinical diagnosis and animal studies, but can also be used to study metabolic and physiological functions in plants dynamically and in vivo. A very particular tracer molecule is (11)CO(2) since it can be applied to a leaf as a gas. We have developed a Plant Tomographic Imaging System (PlanTIS), a high-resolution PET scanner for plant studies. Detectors, front-end electronics and data acquisition architecture of the scanner are based on the ClearPET system. The detectors consist of LSO and LuYAP crystals in phoswich configuration which are coupled to position-sensitive photomultiplier tubes. Signals are continuously sampled by free running ADCs, and data are stored in a list mode format. The detectors are arranged in a horizontal plane to allow the plants to be measured in the natural upright position. Two groups of four detector modules stand face-to-face and rotate around the field-of-view. This special system geometry requires dedicated image reconstruction and normalization procedures. We present the initial performance of the detector system and first phantom and plant measurements.
Cerebral blood flow tomography with xenon-133
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lassen, N.A.
1985-10-01
Cerebral blood flow (CBF) can be measured tomographically by inhalation of Xenon-/sup 133/. The calculation is based on taking a sequence of tomograms during the wash-in and wash-out phase of the tracer. Due to the dynamic nature of the process, a highly sensitive and fast moving single photon emission computed tomograph (SPECT) is required. Two brain-dedicated SPECT systems designed for this purpose are mentioned, and the method is described with special reference to the limitations inherent in the soft energy of the 133Xe primary photons. CBF tomography can be used for a multitude of clinical and investigative purposes. This articlemore » discusses in particular its use for the selection of patients with carotid occlusion for extracranial/intracranial bypass surgery, for detection of severe arterial spasm after aneurysm bleeding, and for detection of low flow areas during severe migraine attacks. The use of other tracers for CBF tomography using SPECT is summarized with emphasis on the /sup 99m/Tc chelates that freely pass the intact blood-brain barrier. The highly sensitive brain-dedicated SPECT systems described are a prerequisite for achieving high resolution tomograms with such tracers.« less
Tomographic reconstruction of tokamak plasma light emission using wavelet-vaguelette decomposition
NASA Astrophysics Data System (ADS)
Schneider, Kai; Nguyen van Yen, Romain; Fedorczak, Nicolas; Brochard, Frederic; Bonhomme, Gerard; Farge, Marie; Monier-Garbet, Pascale
2012-10-01
Images acquired by cameras installed in tokamaks are difficult to interpret because the three-dimensional structure of the plasma is flattened in a non-trivial way. Nevertheless, taking advantage of the slow variation of the fluctuations along magnetic field lines, the optical transformation may be approximated by a generalized Abel transform, for which we proposed in Nguyen van yen et al., Nucl. Fus., 52 (2012) 013005, an inversion technique based on the wavelet-vaguelette decomposition. After validation of the new method using an academic test case and numerical data obtained with the Tokam 2D code, we present an application to an experimental movie obtained in the tokamak Tore Supra. A comparison with a classical regularization technique for ill-posed inverse problems, the singular value decomposition, allows us to assess the efficiency. The superiority of the wavelet-vaguelette technique is reflected in preserving local features, such as blobs and fronts, in the denoised emissivity map.
NASA Astrophysics Data System (ADS)
Nguyen van yen, R.; Fedorczak, N.; Brochard, F.; Bonhomme, G.; Schneider, K.; Farge, M.; Monier-Garbet, P.
2012-01-01
Images acquired by cameras installed in tokamaks are difficult to interpret because the three-dimensional structure of the plasma is flattened in a non-trivial way. Nevertheless, taking advantage of the slow variation of the fluctuations along magnetic field lines, the optical transformation may be approximated by a generalized Abel transform, for which we propose an inversion technique based on the wavelet-vaguelette decomposition. After validation of the new method using an academic test case and numerical data obtained with the Tokam 2D code, we present an application to an experimental movie obtained in the tokamak Tore Supra. A comparison with a classical regularization technique for ill-posed inverse problems, the singular value decomposition, allows us to assess the efficiency. The superiority of the wavelet-vaguelette technique is reflected in preserving local features, such as blobs and fronts, in the denoised emissivity map.
Compact conscious animal positron emission tomography scanner
Schyler, David J.; O'Connor, Paul; Woody, Craig; Junnarkar, Sachin Shrirang; Radeka, Veljko; Vaska, Paul; Pratte, Jean-Francois; Volkow, Nora
2006-10-24
A method of serially transferring annihilation information in a compact positron emission tomography (PET) scanner includes generating a time signal for an event, generating an address signal representing a detecting channel, generating a detector channel signal including the time and address signals, and generating a composite signal including the channel signal and similarly generated signals. The composite signal includes events from detectors in a block and is serially output. An apparatus that serially transfers annihilation information from a block includes time signal generators for detectors in a block and an address and channel signal generator. The PET scanner includes a ring tomograph that mounts onto a portion of an animal, which includes opposing block pairs. Each of the blocks in a block pair includes a scintillator layer, detection array, front-end array, and a serial encoder. The serial encoder includes time signal generators and an address signal and channel signal generator.
Two-dimensional AXUV-based radiated power density diagnostics on NSTX-Ua)
NASA Astrophysics Data System (ADS)
Faust, I.; Delgado-Aparicio, L.; Bell, R. E.; Tritz, K.; Diallo, A.; Gerhardt, S. P.; LeBlanc, B.; Kozub, T. A.; Parker, R. R.; Stratton, B. C.
2014-11-01
A new set of radiated-power-density diagnostics for the National Spherical Torus Experiment Upgrade (NSTX-U) tokamak have been designed to measure the two-dimensional poloidal structure of the total photon emissivity profile in order to perform power balance, impurity transport, and magnetohydrodynamic studies. Multiple AXUV-diode based pinhole cameras will be installed in the same toroidal angle at various poloidal locations. The local emissivity will be obtained from several types of tomographic reconstructions. The layout and response expected for the new radially viewing poloidal arrays will be shown for different impurity concentrations to characterize the diagnostic sensitivity. The radiated power profile inverted from the array data will also be used for estimates of power losses during transitions from various divertor configurations in NSTX-U. The effect of in-out and top/bottom asymmetries in the core radiation from high-Z impurities will be addressed.
Two-dimensional AXUV-based radiated power density diagnostics on NSTX-U.
Faust, I; Delgado-Aparicio, L; Bell, R E; Tritz, K; Diallo, A; Gerhardt, S P; LeBlanc, B; Kozub, T A; Parker, R R; Stratton, B C
2014-11-01
A new set of radiated-power-density diagnostics for the National Spherical Torus Experiment Upgrade (NSTX-U) tokamak have been designed to measure the two-dimensional poloidal structure of the total photon emissivity profile in order to perform power balance, impurity transport, and magnetohydrodynamic studies. Multiple AXUV-diode based pinhole cameras will be installed in the same toroidal angle at various poloidal locations. The local emissivity will be obtained from several types of tomographic reconstructions. The layout and response expected for the new radially viewing poloidal arrays will be shown for different impurity concentrations to characterize the diagnostic sensitivity. The radiated power profile inverted from the array data will also be used for estimates of power losses during transitions from various divertor configurations in NSTX-U. The effect of in-out and top/bottom asymmetries in the core radiation from high-Z impurities will be addressed.
SXR measurement and W transport survey using GEM tomographic system on WEST
NASA Astrophysics Data System (ADS)
Mazon, D.; Jardin, A.; Malard, P.; Chernyshova, M.; Coston, C.; Malard, P.; O'Mullane, M.; Czarski, T.; Malinowski, K.; Faisse, F.; Ferlay, F.; Verger, J. M.; Bec, A.; Larroque, S.; Kasprowicz, G.; Wojenski, A.; Pozniak, K.
2017-11-01
Measuring Soft X-Ray (SXR) radiation (0.1-20 keV) of fusion plasmas is a standard way of accessing valuable information on particle transport. Since heavy impurities like tungsten (W) could degrade plasma core performances and cause radiative collapses, it is necessary to develop new diagnostics to be able to monitor the impurity distribution in harsh fusion environments like ITER. A gaseous detector with energy discrimination would be a very good candidate for this purpose. The design and implementation of a new SXR diagnostic developed for the WEST project, based on a triple Gas Electron Multiplier (GEM) detector is presented. This detector works in photon counting mode and presents energy discrimination capabilities. The SXR system is composed of two 1D cameras (vertical and horizontal views respectively), located in the same poloidal cross-section to allow for tomographic reconstruction. An array (20 cm × 2 cm) consists of up to 128 detectors in front of a beryllium pinhole (equipped with a 1 mm diameter diaphragm) inserted at about 50 cm depth inside a cooled thimble in order to retrieve a wide plasma view. Acquisition of low energy spectrum is insured by a helium buffer installed between the pinhole and the detector. Complementary cooling systems (water) are used to maintain a constant temperature (25oC) inside the thimble. Finally a real-time automatic extraction system has been developed to protect the diagnostic during baking phases or any overheating unwanted events. Preliminary simulations of plasma emissivity and W distribution have been performed for WEST using a recently developed synthetic diagnostic coupled to a tomographic algorithm based on the minimum Fisher information (MFI) inversion method. First GEM acquisitions are presented as well as estimation of transport effect in presence of ICRH on W density reconstruction capabilities of the GEM.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stratton, J.R.; Ritchie, J.L.
Aspirin plus dipyridamole reduces platelet accumulation on short-term Dacron vascular grafts in man. To determine whether drug inhibition of platelet deposition is sustained on older grafts, we studied 18 men aged 41 to 87 years who had Dacron aortic bifurcation grafts in place a mean of 43.4 months (range 9.8 to 121.0) before and during short-term therapy with aspirin (325 mg tid) plus dipyridamole (75 mg tid). During both the baseline and drug studies, indium-111 (/sup 111/In) platelet deposition was quantitated by two techniques, standard planar imaging performed at 24, 48, and 72 hr after injection of platelets and singlemore » photon emission computed tomographic imaging performed at 24 and 72 hr after injection. All analyses were performed in a blinded fashion. On both the planar and tomographic images, platelet accumulation on the graft was quantitated by a graft/blood ratio that compared activity in the graft to simultaneously collected whole blood /sup 111/In platelet activity. Aspirin plus dipyridamole reduced the tomographic graft/blood ratio at 24 hr (20.6 +/- 3.5 vs 17.3 +/- 2.5) (+/-SEM) and at 72 hr (29.0 +/- 4.8 vs 25.0 +/- 4.1) after injection of platelets (p = .02). Dacron vascular grafts. Similarly, the planar graft/blood ratio was reduced at 24 hr (2.7 +/- 0.5 vs 2.4 +/- 0.5), 48 hr (3.7 +/- 0.9 vs 3.1 +/- 0.7), and 72 hr (4.0 +/- 0.9 vs 3.6 +/- 0.8) (p = .04). We conclude that aspirin (325 mg tid) plus dipyridamole (75 mg tid) reduces platelet accumulation on long-term Dacron vascular grafts.« less
Tomographic diagnostics of nonthermal plasmas
NASA Astrophysics Data System (ADS)
Denisova, Natalia
2009-10-01
In the previous work [1], we discussed a ``technology'' of tomographic method and relations between the tomographic diagnostics in thermal (equilibrium) and nonthermal (nonequilibrium) plasma sources. The conclusion has been made that tomographic reconstruction in thermal plasma sources is the standard procedure at present, which can provide much useful information on the plasma structure and its evolution in time, while the tomographic reconstruction of nonthermal plasma has a great potential at making a contribution to understanding the fundamental problem of substance behavior in strongly nonequilibrium conditions. Using medical terminology, one could say, that tomographic diagnostics of the equilibrium plasma sources studies their ``anatomic'' structure, while reconstruction of the nonequilibrium plasma is similar to the ``physiological'' examination: it is directed to study the physical mechanisms and processes. The present work is focused on nonthermal plasma research. The tomographic diagnostics is directed to study spatial structures formed in the gas discharge plasmas under the influence of electrical and gravitational fields. The ways of plasma ``self-organization'' in changing and extreme conditions are analyzed. The analysis has been made using some examples from our practical tomographic diagnostics of nonthermal plasma sources, such as low-pressure capacitive and inductive discharges. [0pt] [1] Denisova N. Plasma diagnostics using computed tomography method // IEEE Trans. Plasma Sci. 2009 37 4 502.
Electrical Impedance Tomography Technology (EITT) Project
NASA Technical Reports Server (NTRS)
Oliva-Buisson, Yvette J.
2014-01-01
Development of a portable, lightweight device providing two-dimensional tomographic imaging of the human body using impedance mapping. This technology can be developed to evaluate health risks and provide appropriate medical care on the ISS, during space travel and on the ground.
Extranodal manifestations of lymphoma on [18F]FDG-PET/CT: a pictorial essay
Kashyap, Raghava; Manohar, Kuruva; Harisankar, Chidambaram Natrajan Balasubramanian; Bhattacharya, Anish; Singh, Baljinder; Malhotra, Pankaj; Varma, Subhash
2011-01-01
Abstract Lymphoma is the seventh most common type of malignancy in both sexes. It is a neoplastic proliferation of lymphoid cells at various stages of differentiation and affects lymph nodes with infiltration into the bone marrow, spleen and thymus. However, extra nodal involvement is frequently seen in many cases. With the development of dedicated positron emission tomography (PET) scanners with fused computed tomographic (CT) systems in the same gantry, [18F]fluorodeoxyglucose (FDG)-PET/CT has become a major tool in the evaluation of lymphomas and it is inimitable in certain situations such as assessment of response to therapy. Extranodal lymphoma can present with diverse manifestations and sometimes mimics other organ-related pathologies. Knowledge of the protean manifestations of extranodal lymphoma is required to accurately detect the disease and differentiate it from the various physiologic and benign causes of FDG uptake in various organs. We present a case series of extranodal involvement of histologically proven cases of lymphomas detected on FDG-PET/CT at our institute to demonstrate the challenges in interpretation of extranodal lymphoma. PMID:22123338
Experimental evaluation of analyte excitation mechanisms in the inductively coupled plasma
NASA Astrophysics Data System (ADS)
Lehn, Scott A.; Hieftje, Gary M.
2003-10-01
The inductively coupled plasma (ICP) is a justifiably popular source for atomic emission spectrometry. However, despite its popularity, the ICP is still only partially understood. Even the mechanisms of analyte excitation remain unclear; some energy levels are quite clearly populated by charge transfer while others might be populated by electron-ion recombination, by electron impact, or by Penning processes. Distinguishing among these alternatives is possible by means of a steady-state kinetics approach that examines correlations between the emission of a selected atom, ion, or level and the local number densities of species assumed to produce the excitation. In an earlier investigation, strong correlations were found between either calcium atom or ion emission and selected combinations of calcium atom or ion number densities and electron number densities in the plasma. However, all radially resolved data employed in the earlier study were produced from Abel inversion and from measurements that were crude by today's standards. Now, by means of tomographic imaging, laser-saturated atomic fluorescence, and Thomson and Rayleigh scattering, it is possible to measure the required radially resolved data without Abel inversion and with far greater fidelity. The correlations previously studied for calcium have been investigated with these more reliable data. Ion-electron recombination, either radiative or with argon as a third body, was determined to be the most likely excitation mechanism for calcium atom, while electron impact appeared to be the most important process to produce excite-state calcium ions. These results were consistent with the previous study. However, the present study suggests that collisional deactivation, rather than radiative decay, is the most likely mode of returning both calcium atoms and ions to the ground state.
DOE Office of Scientific and Technical Information (OSTI.GOV)
McPherson, D.W.; Luo, H.; Knapp, F.F. Jr.
1994-06-01
Alterations in the density of acetylcholinergic muscarinic receptors (m-AChR) have been observed in various dementias. This has spurred interest in the development of radiohalogenated ligands which can be used for the non-invasive in vivo detection of m-AChR by nuclear medicine techniques. We have developed a new ligand 1-azabicyclo[2.2.2]oct-3-yl ({alpha}-hydroxy-{alpha}-(1-iodo-1-propen-3-yl)-{alpha}-phenylacetate (IQNP,12) which demonstrates high affinity for the muscarinic receptor. When labeled with radioiodine it has been shown to be selective and specific for m-ACHR. Initial studies on the separation and in vivo evaluation of the various isomers of IQNP have shown that the stereochemistry of the chiral centers and the configurationmore » around the double bond play an important role in m-AChR subtype specificity. In vivo evaluation of these stereoisomers demonstrate that E-(R,R)-IQNP has a high affinity for the M{sub 1} muscarinic subtype while Z-(R,R)-IQNP demonstrate a high affinity for M{sub 1} and M{sub 2} receptor subtypes. These data demonstrate IQNP (12) has potential for use in the non-evasive in vivo detection of m-AChR by single photon emission computed tomography (SPECT). A brominated analogue, ``BrQNP,`` in which the iodine has been replaced by a bromine atom, has also been prepared and was shown to block the in vivo uptake of IQNP in the brain and heart and therefore has potential for positron emission tomographic (PET) studies of m-AChR.« less
Mizukawa, N; Hino, A; Imahori, Y; Tenjin, H; Yano, I; Yoshino, E; Hirakawa, K; Yamashita, M; Oki, F; Nakahashi, H
1989-03-01
Blood flow and glucose metabolism of the tumors and perifocal edematous tissues were evaluated using positron emission tomography (PET). Thirty-one brain tumor cases were investigated 12 non glial tumors (9 meningiomas and 3 metastatic tumors) and 19 gliomas (these were classified in 5 astrocytomas, 7 anaplastic astrocytomas and 7 glioblastomas, according to the malignancy). The diagnosis were confirmed pathologically in 30 cases. Cerebral blood flow (CBF), cerebral metabolic rate for oxygen (CMRO2), oxygen extraction fraction (OEF) and cerebral blood volume (CBV) were measured by O-15 labeled gases inhalation methods. Cerebral metabolic rate for glucose (CMFglu) were measured by F-18 Deoxyglucose intravenous injection method and calculated by Hutchins's formula. The rate constant (ks) and lumped constant (LC) used in this study were the same as those published by Phelps et al. in 1979. The blood flow and glucose metabolic rates of tumors were measured by the same methods. The results were as follows: 1) Meningiomas showed very high blood flow and blood volume with a wide range. The OEF and metabolic rate for glucose (MRglu) values were very low. 2) Metastatic tumors showed the low values of blood flow, metabolic rate for oxygen (MRO2) and OEF. 3) The blood flow and MRglu values on gliomas were varied with no significant differences between the three subgroups. On the other hands, as the malignancy of the glioma increased, a statistically significant increase in blood volume and a decrease in OEF were noted. 4) The OEF values from the various types of tumors studied were significantly lower than those obtained from the normal tissue.(ABSTRACT TRUNCATED AT 250 WORDS)
Tomographic image of a seismically active volcano: Mammoth Mountain, California
Dawson, Phillip B.; Chouet, Bernard A.; Pitt, Andrew M.
2016-01-01
High-resolution tomographic P wave, S wave, and VP/VS velocity structure models are derived for Mammoth Mountain, California, using phase data from the Northern California Seismic Network and a temporary deployment of broadband seismometers. An anomalous volume (5.1 × 109 to 5.9 × 1010m3) of low P and low S wave velocities is imaged beneath Mammoth Mountain, extending from near the surface to a depth of ∼2 km below sea level. We infer that the reduction in seismic wave velocities is due to the presence of CO2 distributed in oblate spheroid pores with mean aspect ratio α = 1.6 × 10−3 to 7.9 × 10−3 (crack-like pores) and mean gas volume fraction ϕ = 8.1 × 10−4 to 3.4 × 10−3. The pore density parameter κ = 3ϕ/(4πα) = na3=0.11, where n is the number of pores per cubic meter and a is the mean pore equatorial radius. The total mass of CO2 is estimated to be 4.6 × 109 to 1.9 × 1011 kg. The local geological structure indicates that the CO2 contained in the pores is delivered to the surface through fractures controlled by faults and remnant foliation of the bedrock beneath Mammoth Mountain. The total volume of CO2 contained in the reservoir suggests that given an emission rate of 500 tons day−1, the reservoir could supply the emission of CO2 for ∼25–1040 years before depletion. Continued supply of CO2 from an underlying magmatic system would significantly prolong the existence of the reservoir.
Tomographic Image of a Seismically Active Volcano: Mammoth Mountain, California
NASA Astrophysics Data System (ADS)
Dawson, P. B.; Chouet, B. A.; Pitt, A. M.
2015-12-01
High-resolution tomographic P wave, S wave, and VP /VS velocity structure models are derived for Mammoth Mountain, California using phase data from the Northern California Seismic Network and a temporary deployment of broadband seismometers. An anomalous volume (˜50 km3) of low P and low S wave velocities is imaged beneath Mammoth Mountain, extending from near the surface to a depth of ˜2 km below sea level. We infer that the reduction in seismic wave velocities is primarily due to the presence of CO2 distributed in oblate-spheroid pores with mean aspect ratio α ˜8 x 10-4 (crack-like pores) and gas volume fraction φ ˜4 x 10-4. The pore density parameter κ = 3φ / (4πα) = na3 = 0.12, where n is the number of pores per cubic meter and a is the mean pore equatorial radius. The total mass of CO2 is estimated to range up to ˜1.6 x 1010 kg if the pores exclusively contain CO2, although he presence of an aqueous phase may lower this estimate by up to one order of magnitude. The local geological structure indicates that the CO2 contained in the pores is delivered to the surface through fractures controlled by faults and remnant foliation of the bedrock beneath Mammoth Mountain. The total volume of CO2 contained in the reservoir suggests that given an emission rate of 5 x 105 kg day-1, the reservoir could supply the emission of CO2 for ˜8 to ˜90 years before depletion. Continued supply of CO2 from an underlying magmatic system would significantly prolong the existence of the reservoir.
Tomographic image of a seismically active volcano: Mammoth Mountain, California
NASA Astrophysics Data System (ADS)
Dawson, Phillip; Chouet, Bernard; Pitt, Andrew
2016-01-01
High-resolution tomographic P wave, S wave, and VP/VS velocity structure models are derived for Mammoth Mountain, California, using phase data from the Northern California Seismic Network and a temporary deployment of broadband seismometers. An anomalous volume (5.1 × 109 to 5.9 × 1010m3) of low P and low S wave velocities is imaged beneath Mammoth Mountain, extending from near the surface to a depth of ˜2 km below sea level. We infer that the reduction in seismic wave velocities is due to the presence of CO2 distributed in oblate spheroid pores with mean aspect ratio α = 1.6 × 10-3 to 7.9 × 10-3 (crack-like pores) and mean gas volume fraction ϕ = 8.1 × 10-4 to 3.4 × 10-3. The pore density parameter κ = 3ϕ/(4πα) = na3=0.11, where n is the number of pores per cubic meter and a is the mean pore equatorial radius. The total mass of CO2 is estimated to be 4.6 × 109 to 1.9 × 1011 kg. The local geological structure indicates that the CO2 contained in the pores is delivered to the surface through fractures controlled by faults and remnant foliation of the bedrock beneath Mammoth Mountain. The total volume of CO2 contained in the reservoir suggests that given an emission rate of 500 tons day-1, the reservoir could supply the emission of CO2 for ˜25-1040 years before depletion. Continued supply of CO2 from an underlying magmatic system would significantly prolong the existence of the reservoir.
NASA Astrophysics Data System (ADS)
Camera, S.; Fornasa, M.; Fornengo, N.; Regis, M.
2015-06-01
We recently proposed to cross-correlate the diffuse extragalactic γ-ray background with the gravitational lensing signal of cosmic shear. This represents a novel and promising strategy to search for annihilating or decaying particle dark matter (DM) candidates. In the present work, we demonstrate the potential of a tomographic-spectral approach: measuring the cross-correlation in separate bins of redshift and energy significantly improves the sensitivity to a DM signal. Indeed, the technique proposed here takes advantage of the different scaling of the astrophysical and DM components with redshift and, simultaneously of their different energy spectra and different angular extensions. The sensitivity to a particle DM signal is extremely promising even when the DM-induced emission is quite faint. We first quantify the prospects of detecting DM by cross-correlating the Fermi Large Area Telescope (LAT) diffuse γ-ray background with the cosmic shear expected from the Dark Energy Survey. Under the hypothesis of a significant subhalo boost, such a measurement can deliver a 5σ detection of DM, if the DM particle is lighter than 300 GeV and has a thermal annihilation rate. We then forecast the capability of the European Space Agency Euclid satellite (whose launch is planned for 2020), in combination with an hypothetical future γ-ray detector with slightly improved specifications compared to current telescopes. We predict that the cross-correlation of their data will allow a measurement of the DM mass with an uncertainty of a factor of 1.5-2, even for moderate subhalo boosts, for DM masses up to few hundreds of GeV and thermal annihilation rates.
Occult fractures of the knee: tomographic evaluation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Apple, J.S.; Martinez, S.; Allen, N.B.
1983-08-01
Seven adults with painful effusions of the knee were examined for occult fractures using pluridirectional tomograph in the coronal and lateral planes. Six patients (ages 50 to 82 years) were osteopenic and gave histories ranging from none to mild trauma; one 26-year-old man was not osteopenic and had severe trauma. In all cases, routine radiographs were interpreted as negative, but tomography demonstrated a fracture. Five fractures were subchondral. Bone scans in 2 patients were positive. The authors conclude that osteopenic patients with a painful effusion of the knee should be considered to have an occult fracture. While bone scans maymore » be helpful, tomography is recommended as the procedure of choice to define the location and extent of the fracture.« less
NASA Astrophysics Data System (ADS)
Wagner, L.
2007-12-01
There have been a number of recent papers (i.e. Lee (2003), James et al. (2004), Hacker and Abers (2004), Schutt and Lesher (2006)) which calculate predicted velocities for xenolith compositions at mantle pressures and temperatures. It is tempting, therefore, to attempt to go the other way ... to use tomographically determined absolute velocities to constrain mantle composition. However, in order to do this, it is vital that one is able to accurately constrain not only the polarity of the determined velocity deviations (i.e. fast vs slow) but also how much faster, how much slower relative to the starting model, if absolute velocities are to be so closely analyzed. While much attention has been given to issues concerning spatial resolution in seismic tomography (i.e. what areas are fast, what areas are slow), little attention has been directed at the issue of amplitude resolution (how fast, how slow). Velocity deviation amplitudes in seismic tomography are heavily influenced by the amount of regularization used and the number of iterations performed. Determining these two parameters is a difficult and little discussed problem. I explore the effect of these two parameters on the amplitudes obtained from the tomographic inversion of the Chile Argentina Geophysical Experiment (CHARGE) dataset, and attempt to determine a reasonable solution space for the low Vp, high Vs, low Vp/Vs anomaly found above the flat slab in central Chile. I then compare this solution space to the range in experimentally determined velocities for peridotite end-members to evaluate our ability to constrain composition using tomographically determined seismic velocities. I find that in general, it will be difficult to constrain the compositions of normal mantle peridotites using tomographically determined velocities, but that in the unusual case of the anomaly above the flat slab, the observed velocity structure still has an anomalously high S wave velocity and low Vp/Vs ratio that is most consistent with enstatite, but inconsistent with the predicted velocities of known mantle xenoliths.
Sousa, Thiago Oliveira; Haiter-Neto, Francisco; Nascimento, Eduarda Helena Leandro; Peroni, Leonardo Vieira; Freitas, Deborah Queiroz; Hassan, Bassam
2017-07-01
The aim of this study was to assess the diagnostic accuracy of periapical radiography (PR) and cone-beam computed tomographic (CBCT) imaging in the detection of the root canal configuration (RCC) of human premolars. PR and CBCT imaging of 114 extracted human premolars were evaluated by 2 oral radiologists. RCC was recorded according to Vertucci's classification. Micro-computed tomographic imaging served as the gold standard to determine RCC. Accuracy, sensitivity, specificity, and predictive values were calculated. The Friedman test compared both PR and CBCT imaging with the gold standard. CBCT imaging showed higher values for all diagnostic tests compared with PR. Accuracy was 0.55 and 0.89 for PR and CBCT imaging, respectively. There was no difference between CBCT imaging and the gold standard, whereas PR differed from both CBCT and micro-computed tomographic imaging (P < .0001). CBCT imaging was more accurate than PR for evaluating different types of RCC individually. Canal configuration types III, VII, and "other" were poorly identified on CBCT imaging with a detection accuracy of 50%, 0%, and 43%, respectively. With PR, all canal configurations except type I were poorly visible. PR presented low performance in the detection of RCC in premolars, whereas CBCT imaging showed no difference compared with the gold standard. Canals with complex configurations were less identifiable using both imaging methods, especially PR. Copyright © 2017 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Cappellozza, José Antonio Zuega; Guedes, Fabio Pinto; Nary, Hugo; Capelozza, Leopoldino; Cardoso, Mauricio de Almeida
2015-01-01
Introduction: Cone-Beam Computed Tomography (CBCT) is essential for tridimensional planning of orthognathic surgery, as it allows visualization and evaluation of bone structures and mineralized tissues. Tomographic slices allow evaluation of tooth inclination and individualization of movement performed during preoperative decompensation. The aim of this paper was to assess maxillary and mandibular incisors inclination pre and post orthodontic decompensation in skeletal Class III malocclusion. Methods: The study was conducted on six individuals with skeletal Class III malocclusion, surgically treated, who had Cone-Beam Computed Tomographic scans obtained before and after orthodontic decompensation. On multiplanar reconstruction view, tomographic slices (axial, coronal and sagittal) were obtained on the long axis of each incisor. The sagittal slice was used for measurement taking, whereas the references used to assess tooth inclination were the long axis of maxillary teeth in relation to the palatal plane and the long axis of mandibular teeth in relation to the mandibular plane. Results: There was significant variation in the inclination of incisors before and after orthodontic decompensation. This change was of greater magnitude in the mandibular arch, evidencing that natural compensation is more effective in this arch, thereby requiring more intensive decompensation. Conclusion: When routinely performed, the protocols of decompensation treatment in surgical individuals often result in intensive movements, which should be reevaluated, since the extent of movement predisposes to reduction in bone attachment levels and root length. PMID:26560818
Tomographic Imaging of a Forested Area By Airborne Multi-Baseline P-Band SAR.
Frey, Othmar; Morsdorf, Felix; Meier, Erich
2008-09-24
In recent years, various attempts have been undertaken to obtain information about the structure of forested areas from multi-baseline synthetic aperture radar data. Tomographic processing of such data has been demonstrated for airborne L-band data but the quality of the focused tomographic images is limited by several factors. In particular, the common Fourierbased focusing methods are susceptible to irregular and sparse sampling, two problems, that are unavoidable in case of multi-pass, multi-baseline SAR data acquired by an airborne system. In this paper, a tomographic focusing method based on the time-domain back-projection algorithm is proposed, which maintains the geometric relationship between the original sensor positions and the imaged target and is therefore able to cope with irregular sampling without introducing any approximations with respect to the geometry. The tomographic focusing quality is assessed by analysing the impulse response of simulated point targets and an in-scene corner reflector. And, in particular, several tomographic slices of a volume representing a forested area are given. The respective P-band tomographic data set consisting of eleven flight tracks has been acquired by the airborne E-SAR sensor of the German Aerospace Center (DLR).
DOT National Transportation Integrated Search
2001-06-01
Accurately evaluating the condition of a bridge deck over time and using this information to choose appropriate maintenance techniques has become critical for the efficient allocation of resources to bridge deck maintenance. Tomographic imaging of su...
Wang, Ningli; Wang, Bingsong; Zhai, Gaoshou; Lei, Kun; Wang, Lan; Congdon, Nathan
2007-05-01
To describe and evaluate a new method for measuring anterior chamber volume (ACV). Observational case series. The authors measured ACV using the anterior chamber (AC) optical coherence tomographer (OCT) and applied image-processing software developed by them. Repeatability was evaluated. The ACV was measured in patient groups with normal ACs, shallow ACs, and deep ACs. The volume difference before and after laser peripheral iridotomy (LPI) was analyzed for the shallow and deep groups. Coefficients of repeatability for intraoperator, interoperator, and interimage measurements were 0.406%, 0.958%, and 0.851%, respectively. The limits of agreement for intraoperator and interoperator measurement were -0.911 microl to 1.343 microl and -7.875 microl to -2.463 microl, respectively. There were significant ACV differences in normal, shallow, and deep AC eyes (P < .001) and before and after LPI in shallow AC (P < .001) and deep AC (P = .008) eyes. The ACV values obtained by this method were repeatable and in accord with clinical observation.
Offodile, Anaeze C; Chatterjee, Abhishek; Vallejo, Sergio; Fisher, Carla S; Tchou, Julia C; Guo, Lifei
2015-04-01
Computed tomographic angiography is a diagnostic tool increasingly used for preoperative vascular mapping in abdomen-based perforator flap breast reconstruction. This study compared the use of computed tomographic angiography and the conventional practice of Doppler ultrasonography only in postmastectomy reconstruction using a cost-utility model. Following a comprehensive literature review, a decision analytic model was created using the three most clinically relevant health outcomes in free autologous breast reconstruction with computed tomographic angiography versus Doppler ultrasonography only. Cost and utility estimates for each health outcome were used to derive the quality-adjusted life-years and incremental cost-utility ratio. One-way sensitivity analysis was performed to scrutinize the robustness of the authors' results. Six studies and 782 patients were identified. Cost-utility analysis revealed a baseline cost savings of $3179, a gain in quality-adjusted life-years of 0.25. This yielded an incremental cost-utility ratio of -$12,716, implying a dominant choice favoring preoperative computed tomographic angiography. Sensitivity analysis revealed that computed tomographic angiography was costlier when the operative time difference between the two techniques was less than 21.3 minutes. However, the clinical advantage of computed tomographic angiography over Doppler ultrasonography only showed that computed tomographic angiography would still remain the cost-effective option even if it offered no additional operating time advantage. The authors' results show that computed tomographic angiography is a cost-effective technology for identifying lower abdominal perforators for autologous breast reconstruction. Although the perfect study would be a randomized controlled trial of the two approaches with true cost accrual, the authors' results represent the best available evidence.
Subpercent-Scale Control of 3D Low Modes of Targets Imploded in Direct-Drive Configuration on OMEGA
NASA Astrophysics Data System (ADS)
Michel, D. T.; Igumenshchev, I. V.; Davis, A. K.; Edgell, D. H.; Froula, D. H.; Jacobs-Perkins, D. W.; Goncharov, V. N.; Regan, S. P.; Shvydky, A.; Campbell, E. M.
2018-03-01
Multiple self-emission x-ray images are used to measure tomographically target modes 1, 2, and 3 up to the end of the target acceleration in direct-drive implosions on OMEGA. Results show that the modes consist of two components: the first varies linearly with the laser beam-energy balance and the second is static and results from physical effects including beam mistiming, mispointing, and uncertainty in beam energies. This is used to reduce the target low modes of low-adiabat implosions from 2.2% to 0.8% by adjusting the beam-energy balance to compensate these static modes.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hill, K. W.; Bitter, M. L.; Scott, S. D.
2009-03-24
A new spatially resolving x-ray crystal spectrometer capable of measuring continuous spatial profiles of high resolution spectra (λ/dλ > 6000) of He-like and H-like Ar Kα lines with good spatial (~1 cm) and temporal (~10 ms) resolutions has been installed on the Alcator C-Mod tokamak. Two spherically bent crystals image the spectra onto four two-dimensional Pilatus II pixel detectors. Tomographic inversion enables inference of local line emissivity, ion temperature (Ti), and toroidal plasma rotation velocity (vφ) from the line Doppler widths and shifts. The data analysis techniqu
Multi-pinhole SPECT Imaging with Silicon Strip Detectors
Peterson, Todd E.; Shokouhi, Sepideh; Furenlid, Lars R.; Wilson, Donald W.
2010-01-01
Silicon double-sided strip detectors offer outstanding instrinsic spatial resolution with reasonable detection efficiency for iodine-125 emissions. This spatial resolution allows for multiple-pinhole imaging at low magnification, minimizing the problem of multiplexing. We have conducted imaging studies using a prototype system that utilizes a detector of 300-micrometer thickness and 50-micrometer strip pitch together with a 23-pinhole collimator. These studies include an investigation of the synthetic-collimator imaging approach, which combines multiple-pinhole projections acquired at multiple magnifications to obtain tomographic reconstructions from limited-angle data using the ML-EM algorithm. Sub-millimeter spatial resolution was obtained, demonstrating the basic validity of this approach. PMID:20953300
Gonzalo, Irene T Gaw; Itti, Emmanuel; Mlikotic, Anton; Pham, Le H; Cesar, Romeo B; Meignan, Michel; Mishkin, Fred S
2003-01-01
To evaluate the feasibility of using [(18)F]fluorodeoxyglucose ((18)FDG) triple-head coincidence imaging as a potential cost-effective alternative to positron emission tomography in the setting of suspected recurrence of papillary thyroid carcinoma. We retrospectively studied 10 patients with suspected recurrence of papillary carcinoma of the thyroid, who underwent (18)FDG coincidence imaging,(131)I scanning, and a reference anatomic scan (computed tomography, magnetic resonance imaging, or both) within 1 year in most cases. The (131)I scan detected the recurrence in five patients (62.5%) and failed to reveal recurrent cancer in three patients (37.5%); in contrast,(18)FDG imaging detected the recurrence in eight patients (100%) and was true negative in two patients in whom the scans were performed more than 1 year after effective therapy for the recurrence. The sensitivity of detection was unrelated to lesion size. The (18)FDG imaging results led to additional radiotherapy in all (131)I-negative patients, two of whom had high thyroglobulin levels and one of whom had a low thyroglobulin concentration but the presence of antithy-roglobulin antibodies. We conclude that (18)FDG triple-head coincidence imaging is useful for routine management of patients with thyroid cancer who have no abnormalities detected on (131)I scans but have high serum thyroglobulin levels. This technique, however, may not be as sensitive as a dedicated positron emission tomographic device, particularly for the assessment of small tumors.
Hernigou, P; Germany, W
1998-09-01
Within an anatomical and a clinical study, the authors employed computerized tomographic scans to evaluate the risks of anterior surrounding tissues injuries during screw insertion. CT scans of 20 patients suffering from cardiac disease were reviewed retrospectively. Scans through the thoracic and lumbar spine were obtained using 6 mm slice thickness. These examinations were performed with intravenous contrast medium. Measurements of vessel diameters and distance of the soft tissues situated directly anterior to the spine were done. A retrospective study of 61 pedicle screws implanted for spine fractures evaluated the penetration of the anterior vertebral cordex with X rays and CT scans. Computerized tomographic scans of the thoracic and lumbar spine of the 20 patients in the control group confirmed proximity of the posterior mediastinal structures to the anterior vertebral cortex. Many structures of the posterior mediastinum were within five millimeters of the anterior vertebral cortex and thus were at risk: aorta, azygos vein, vena cava, parietal pleura and lungs. The theoretical risk of unrecognized screw penetrations evaluated on geometric shape of the anterior vertebral body is as high as 21 per cent when screw position is only seen with an antero posterior and a lateral X Ray. In the other group, computerized tomographic scans showed that 30 per cent of the implanted screws were outside the boundaries of the anterior thoracic spine. Two orthogonal incidences do not enable determination of whether the extremity of the screw is slightly outside the anterior cortex of the vertebral body. However the geometric shape of the anterior vertebral body enables peroperative definition of a safety zone on two orthogonal incidences. Even if a breach of a few millimeters of the anterior cortical boundaries of the vertebral body may not initially damage the adjacent soft-tissue structures, chronic irritation may result in late damages of these structures. The use of metallic markers and the respect of a safe vertebral zone on X Rays could guide the choice of the appropriate screw length.
Surface Wave Tomography with Spatially Varying Smoothing Based on Continuous Model Regionalization
NASA Astrophysics Data System (ADS)
Liu, Chuanming; Yao, Huajian
2017-03-01
Surface wave tomography based on continuous regionalization of model parameters is widely used to invert for 2-D phase or group velocity maps. An inevitable problem is that the distribution of ray paths is far from homogeneous due to the spatially uneven distribution of stations and seismic events, which often affects the spatial resolution of the tomographic model. We present an improved tomographic method with a spatially varying smoothing scheme that is based on the continuous regionalization approach. The smoothness of the inverted model is constrained by the Gaussian a priori model covariance function with spatially varying correlation lengths based on ray path density. In addition, a two-step inversion procedure is used to suppress the effects of data outliers on tomographic models. Both synthetic and real data are used to evaluate this newly developed tomographic algorithm. In the synthetic tests, when the contrived model has different scales of anomalies but with uneven ray path distribution, we compare the performance of our spatially varying smoothing method with the traditional inversion method, and show that the new method is capable of improving the recovery in regions of dense ray sampling. For real data applications, the resulting phase velocity maps of Rayleigh waves in SE Tibet produced using the spatially varying smoothing method show similar features to the results with the traditional method. However, the new results contain more detailed structures and appears to better resolve the amplitude of anomalies. From both synthetic and real data tests we demonstrate that our new approach is useful to achieve spatially varying resolution when used in regions with heterogeneous ray path distribution.
Tomographic Reconstruction from a Few Views: A Multi-Marginal Optimal Transport Approach
DOE Office of Scientific and Technical Information (OSTI.GOV)
Abraham, I., E-mail: isabelle.abraham@cea.fr; Abraham, R., E-mail: romain.abraham@univ-orleans.fr; Bergounioux, M., E-mail: maitine.bergounioux@univ-orleans.fr
2017-02-15
In this article, we focus on tomographic reconstruction. The problem is to determine the shape of the interior interface using a tomographic approach while very few X-ray radiographs are performed. We use a multi-marginal optimal transport approach. Preliminary numerical results are presented.
A novel optical detector concept for dedicated and multi-modality in vivo small animal imaging
NASA Astrophysics Data System (ADS)
Peter, Jörg; Schulz, Ralf B.; Unholtz, Daniel; Semmler, Wolfhard
2007-07-01
An optical detector suitable for inclusion in tomographic arrangements for non-contact in vivo bioluminescence and fluorescence imaging applications is proposed. It consists of a microlens array (MLA) intended for field-of-view definition, a large-field complementary metal-oxide-semiconductor (CMOS) chip for light detection, a septum mask for cross-talk suppression, and an exchangeable filter to block excitation light. Prototype detector units with sensitive areas of 2.5 cm x 5 cm each were assembled. The CMOS sensor constitutes a 512 x 1024 photodiode matrix at 48 μm pixel pitch. Refractive MLAs with plano-convex lenses of 480 μm in diameter and pitch were selected resulting in a 55 x 105 lens matrix. The CMOS sensor is aligned on the focal plane of the MLA at 2.15mm distance. To separate individual microlens images an opaque multi-bore septum mask of 2.1mm in thickness and bore diameters of 400 μm at 480 μm pitch, aligned with the lens pattern, is placed between MLA and CMOS. Intrinsic spatial detector resolution and sensitivity was evaluated experimentally as a function of detector-object distance. Due to its small overall dimensions such detectors can be favorably packed for tomographic imaging (optical diffusion tomography, ODT) yielding complete 2 π field-of-view coverage. We also present a design study of a device intended to simultaneously image positron labeled substrates (positron emission tomography, PET) and optical molecular probes in small animals such as mice and rats. It consists of a cylindrical allocation of optical detector units which form an inner detector ring while PET detector blocks are mounted in radial extension, those gaining complementary information in a single, intrinsically coregistered experimental data acquisition study. Finally, in a second design study we propose a method for integrated optical and magnetic resonance imaging (MRI) which yields in vivo functional/molecular information that is intrinsically registered with the anatomy of the image object.
Lionberger, David R; Weise, Jennifer; Ho, David M; Haddad, John L
2008-06-01
Forty-six primary total knee arthroplasties were performed using either an electromagnetic (EM) or infrared (IR) navigation system. In this IRB-approved study, patients were evaluated clinically and for accuracy using spiral computed tomographic imaging and 36-in standing radiographs. Although EM navigation was subject to metal interference, it was not as drastic as line-of-sight interference with IR navigation. Mechanical alignment was ideal in 92.9% of EM and 90.0% of IR cases based on spiral computed tomographic imaging and 100% of EM and 95% of IR cases based on x-ray. Individual measurements of component varus/valgus and sagittal measurements showed EM to be equivalent to IR, with both systems producing subdegree accuracy in 95% of the readings.
Preliminary studies of a simultaneous PET/MRI scanner based on the RatCAP small animal tomograph
NASA Astrophysics Data System (ADS)
Woody, C.; Schlyer, D.; Vaska, P.; Tomasi, D.; Solis-Najera, S.; Rooney, W.; Pratte, J.-F.; Junnarkar, S.; Stoll, S.; Master, Z.; Purschke, M.; Park, S.-J.; Southekal, S.; Kriplani, A.; Krishnamoorthy, S.; Maramraju, S.; O'Connor, P.; Radeka, V.
2007-02-01
We are developing a scanner that will allow simultaneous acquisition of high resolution anatomical data using magnetic resonance imaging (MRI) and quantitative physiological data using positron emission tomography (PET). The approach is based on the technology used for the RatCAP conscious small animal PET tomograph which utilizes block detectors consisting of pixelated arrays of LSO crystals read out with matching arrays of avalanche photodiodes and a custom-designed ASIC. The version of this detector used for simultaneous PET/MRI imaging will be constructed out of all nonmagnetic materials and will be situated inside the MRI field. We have demonstrated that the PET detector and its electronics can be operated inside the MRI, and have obtained MRI images with various detector components located inside the MRI field. The MRI images show minimal distortion in this configuration even where some components still contain traces of certain magnetic materials. We plan to improve on the image quality in the future using completely non-magnetic components and by tuning the MRI pulse sequences. The combined result will be a highly compact, low mass PET scanner that can operate inside an MRI magnet without distorting the MRI image, and can be retrofitted into existing MRI instruments.
Progress In The Development Of A Tomographic SPECT System For Online Dosimetry In BNCT
NASA Astrophysics Data System (ADS)
Minsky, D. M.; Valda, A.; Kreiner, A. J.; Burlon, A. A.; Green, S.; Wojnecki, C.; Ghani, Z.
2010-08-01
In boron neutron capture therapy (BNCT) the delivered dose to the patient depends both on the neutron beam characteristics and on the 10B body distribution which, in turn, is governed by the tumor specificity of the 10B drug-carrier. BNCT dosimetry is a complex matter due to the several interactions that neutrons can undergo with the different nuclei present in tissue. However the boron capture reaction 10B(n,α)7Li accounts for about 80 % of the total dose in a tumor with 40 ppm in 10B concentration. Present dosimetric methods are indirect, based on drug biodistribution statistical data and subjected to inter and intra-patient variability. In order to overcome the consequences of the concomitant high dosimetric uncertainties, we propose a SPECT (Single Photon Emission Tomography) approach based on the detection of the prompt gamma-ray (478 keV) emitted in 94 % of the cases from 7Li. For this purpose we designed, built and tested a prototype based on LaBr3(Ce) scintillators. Measurements on a head and tumor phantom were performed in the accelerator-based BNCT facility of the University of Birmingham (UK). They result in the first tomographic image of the 10B capture distribution obtained in a BNCT facility.
Rozen, Warren M; Chubb, Daniel; Ashton, Mark W; Webster, Howard R
2012-05-01
The use of advanced imaging technologies such as computed tomographic angiography (CTA) has opened the door to the analysis of microvascular anatomy not previously demonstrable with prior imaging techniques. While CTA has been used to evaluate the vascular anatomy of donor body regions in the planning of harvest of tissue for free flap transfer, the use of CTA to evaluate tissues after tissue transplantation has not been demonstrated. The current study aimed to explore whether vascular anatomy was able to highlight CTA within transferred flaps. The arterial and venous anatomy of a transferred deep inferior epigastric artery (DIEA) perforator (DIEP) flap was explored postoperatively with the use of CTA. Intra-flap vasculature was mapped and recorded qualitatively. Postoperative CTA is able to highlight the vascular pedicle of a transferred free flap, highlight the course of individual perforators supplying the flap, and map the zones of lesser perfusion by the source pedicle. The current study has demonstrated that CTA may be of value in identifying vascular anatomy within transferred tissue, as a guide to evaluate flap perfusion and planning further surgery involving the flap. © Springer-Verlag 2011
Lew, Henry L; Lee, Eun Ha; Miyoshi, Yasushi; Chang, Douglas G; Date, Elaine S; Jerger, James F
2004-03-01
Because of the violent nature of traumatic brain injury, traumatic brain injury patients are susceptible to various types of trauma involving the auditory system. We report a case of a 55-yr-old man who presented with communication problems after traumatic brain injury. Initial results from behavioral audiometry and Weber/Rinne tests were not reliable because of poor cooperation. He was transferred to our service for inpatient rehabilitation, where review of the initial head computed tomographic scan showed only left temporal bone fracture. Brainstem auditory-evoked potential was then performed to evaluate his hearing function. The results showed bilateral absence of auditory-evoked responses, which strongly suggested bilateral deafness. This finding led to a follow-up computed tomographic scan, with focus on bilateral temporal bones. A subtle transverse fracture of the right temporal bone was then detected, in addition to the left temporal bone fracture previously identified. Like children with hearing impairment, traumatic brain injury patients may not be able to verbalize their auditory deficits in a timely manner. If hearing loss is suspected in a patient who is unable to participate in traditional behavioral audiometric testing, brainstem auditory-evoked potential may be an option for evaluating hearing dysfunction.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Häggström, Ida, E-mail: haeggsti@mskcc.org; Beattie, Bradley J.; Schmidtlein, C. Ross
2016-06-15
Purpose: To develop and evaluate a fast and simple tool called dPETSTEP (Dynamic PET Simulator of Tracers via Emission Projection), for dynamic PET simulations as an alternative to Monte Carlo (MC), useful for educational purposes and evaluation of the effects of the clinical environment, postprocessing choices, etc., on dynamic and parametric images. Methods: The tool was developed in MATLAB using both new and previously reported modules of PETSTEP (PET Simulator of Tracers via Emission Projection). Time activity curves are generated for each voxel of the input parametric image, whereby effects of imaging system blurring, counting noise, scatters, randoms, and attenuationmore » are simulated for each frame. Each frame is then reconstructed into images according to the user specified method, settings, and corrections. Reconstructed images were compared to MC data, and simple Gaussian noised time activity curves (GAUSS). Results: dPETSTEP was 8000 times faster than MC. Dynamic images from dPETSTEP had a root mean square error that was within 4% on average of that of MC images, whereas the GAUSS images were within 11%. The average bias in dPETSTEP and MC images was the same, while GAUSS differed by 3% points. Noise profiles in dPETSTEP images conformed well to MC images, confirmed visually by scatter plot histograms, and statistically by tumor region of interest histogram comparisons that showed no significant differences (p < 0.01). Compared to GAUSS, dPETSTEP images and noise properties agreed better with MC. Conclusions: The authors have developed a fast and easy one-stop solution for simulations of dynamic PET and parametric images, and demonstrated that it generates both images and subsequent parametric images with very similar noise properties to those of MC images, in a fraction of the time. They believe dPETSTEP to be very useful for generating fast, simple, and realistic results, however since it uses simple scatter and random models it may not be suitable for studies investigating these phenomena. dPETSTEP can be downloaded free of cost from https://github.com/CRossSchmidtlein/dPETSTEP.« less
System and method for generating motion corrected tomographic images
Gleason, Shaun S [Knoxville, TN; Goddard, Jr., James S.
2012-05-01
A method and related system for generating motion corrected tomographic images includes the steps of illuminating a region of interest (ROI) to be imaged being part of an unrestrained live subject and having at least three spaced apart optical markers thereon. Simultaneous images are acquired from a first and a second camera of the markers from different angles. Motion data comprising 3D position and orientation of the markers relative to an initial reference position is then calculated. Motion corrected tomographic data obtained from the ROI using the motion data is then obtained, where motion corrected tomographic images obtained therefrom.
Optical tomographic memories: algorithms for the efficient information readout
NASA Astrophysics Data System (ADS)
Pantelic, Dejan V.
1990-07-01
Tomographic alogithms are modified in order to reconstruct the inf ormation previously stored by focusing laser radiation in a volume of photosensitive media. Apriori information about the position of bits of inf ormation is used. 1. THE PRINCIPLES OF TOMOGRAPHIC MEMORIES Tomographic principles can be used to store and reconstruct the inf ormation artificially stored in a bulk of a photosensitive media 1 The information is stored by changing some characteristics of a memory material (e. g. refractive index). Radiation from the two independent light sources (e. g. lasers) is f ocused inside the memory material. In this way the intensity of the light is above the threshold only in the localized point where the light rays intersect. By scanning the material the information can be stored in binary or nary format. When the information is stored it can be read by tomographic methods. However the situation is quite different from the classical tomographic problem. Here a lot of apriori information is present regarding the p0- sitions of the bits of information profile representing single bit and a mode of operation (binary or n-ary). 2. ALGORITHMS FOR THE READOUT OF THE TOMOGRAPHIC MEMORIES Apriori information enables efficient reconstruction of the memory contents. In this paper a few methods for the information readout together with the simulation results will be presented. Special attention will be given to the noise considerations. Two different
Crotty, Dominic J; Brady, Samuel L; Jackson, D'Vone C; Toncheva, Greta I; Anderson, Colin E; Yoshizumi, Terry T; Tornai, Martin P
2011-06-01
A dual modality SPECT-CT prototype system dedicated to uncompressed breast imaging (mammotomography) has been developed. The computed tomography subsystem incorporates an ultrathick K-edge filtration technique producing a quasi-monochromatic x-ray cone beam that optimizes the dose efficiency of the system for lesion imaging in an uncompressed breast. Here, the absorbed dose in various geometric phantoms and in an uncompressed and pendant cadaveric breast using a normal tomographic cone beam imaging protocol is characterized using both thermoluminescent dosimeter (TLD) measurements and ionization chamber-calibrated radiochromic film. Initially, two geometric phantoms and an anthropomorphic breast phantom are filled in turn with oil and water to simulate the dose to objects that mimic various breast shapes having effective density bounds of 100% fatty and glandular breast compositions, respectively. Ultimately, an excised human cadaver breast is tomographically scanned using the normal tomographic imaging protocol, and the dose to the breast tissue is evaluated and compared to the earlier phantom-based measurements. Measured trends in dose distribution across all breast geometric and anthropomorphic phantom volumes indicate lower doses in the medial breast and more proximal to the chest wall, with consequently higher doses near the lateral peripheries and nipple regions. Measured doses to the oil-filled phantoms are consistently lower across all volume shapes due to the reduced mass energy-absorption coefficient of oil relative to water. The mean measured dose to the breast cadaver, composed of adipose and glandular tissues, was measured to be 4.2 mGy compared to a mean whole-breast dose of 3.8 and 4.5 mGy for the oil- and water-filled anthropomorphic breast phantoms, respectively. Assuming rotational symmetry due to the tomographic acquisition exposures, these results characterize the 3D dose distributions in an uncompressed human breast tissue volume for this dedicated breast imaging device and illustrate advantages of using the novel ultrathick K-edge filtered beam to minimize the dose to the breast during fully-3D imaging.
Crotty, Dominic J.; Brady, Samuel L.; Jackson, D’Vone C.; Toncheva, Greta I.; Anderson, Colin E.; Yoshizumi, Terry T.; Tornai, Martin P.
2011-01-01
Purpose: A dual modality SPECT-CT prototype system dedicated to uncompressed breast imaging (mammotomography) has been developed. The computed tomography subsystem incorporates an ultrathick K-edge filtration technique producing a quasi-monochromatic x-ray cone beam that optimizes the dose efficiency of the system for lesion imaging in an uncompressed breast. Here, the absorbed dose in various geometric phantoms and in an uncompressed and pendant cadaveric breast using a normal tomographic cone beam imaging protocol is characterized using both thermoluminescent dosimeter (TLD) measurements and ionization chamber-calibrated radiochromic film. Methods: Initially, two geometric phantoms and an anthropomorphic breast phantom are filled in turn with oil and water to simulate the dose to objects that mimic various breast shapes having effective density bounds of 100% fatty and glandular breast compositions, respectively. Ultimately, an excised human cadaver breast is tomographically scanned using the normal tomographic imaging protocol, and the dose to the breast tissue is evaluated and compared to the earlier phantom-based measurements. Results: Measured trends in dose distribution across all breast geometric and anthropomorphic phantom volumes indicate lower doses in the medial breast and more proximal to the chest wall, with consequently higher doses near the lateral peripheries and nipple regions. Measured doses to the oil-filled phantoms are consistently lower across all volume shapes due to the reduced mass energy-absorption coefficient of oil relative to water. The mean measured dose to the breast cadaver, composed of adipose and glandular tissues, was measured to be 4.2 mGy compared to a mean whole-breast dose of 3.8 and 4.5 mGy for the oil- and water-filled anthropomorphic breast phantoms, respectively. Conclusions: Assuming rotational symmetry due to the tomographic acquisition exposures, these results characterize the 3D dose distributions in an uncompressed human breast tissue volume for this dedicated breast imaging device and illustrate advantages of using the novel ultrathick K-edge filtered beam to minimize the dose to the breast during fully-3D imaging. PMID:21815398
Extreme ultraviolet diagnostic upgrades for kink mode control on the HBT-EP tokamak
NASA Astrophysics Data System (ADS)
Levesque, J. P.; Brooks, J. W.; Desanto, S.; Mauel, M. E.; Navratil, G. A.; Page, J. W.; Hansen, C. J.; Delgado-Aparicio, L.
2016-10-01
Optical diagnostics can provide non-invasive measurements of tokamak equilibria and the internal characteristics of MHD mode activity. We present research plans and ongoing progress on upgrading extreme ultraviolet (EUV) diagnostics in the HBT-EP tokamak. Four sets of 16 poloidal views will allow tomographic reconstruction of plasma emissivity and internal kink mode structure. Emission characteristics of naturally-occurring m/n = 2/1, 3/2, and 3/1 tearing and kink modes will be compared with expectations from a synthetic diagnostic. Coupling between internal and external modes leading up to disruptions is studied. The internal plasma response to external magnetic perturbations is investigated, and compared with magnetic response measurements. Correlation between internal emissivity and external magnetic measurements provides a global picture of long-wavelength MHD instabilities. Measurements are input to HBT-EP's GPU-based feedback system, allowing active feedback for kink modes using only optical sensors and both magnetic and edge current actuators. A separate two-color, 16-chord tangential system will be installed next year to allow reconstruction of temperature profiles and their fluctuations versus time. Supported by U.S. DOE Grant DE-FG02-86ER53222.
DOE R&D Accomplishments Database
Phelps, M. E.; Hoffman, E. J.; Huang, S. C.; Schelbert, H. R.; Kuhl, D. E.
1978-01-01
Emission computed tomography can provide a quantitative in vivo measurement of regional tissue radionuclide tracer concentrations. This facility when combined with physiologic models and radioactively labeled physiologic tracers that behave in a predictable manner allow measurement of a wide variety of physiologic variables. This integrated technique has been referred to as Physiologic Tomography (PT). PT requires labeled compounds which trace physiologic processes in a known and predictable manner, and physiologic models which are appropriately formulated and validated to derive physiologic variables from ECT data. In order to effectively achieve this goal, PT requires an ECT system that is capable of performing truly quantitative or analytical measurements of tissue tracer concentrations and which has been well characterized in terms of spatial resolution, sensitivity and signal to noise ratios in the tomographic image. This paper illustrates the capabilities of emission computed tomography and provides examples of physiologic tomography for the regional measurement of cerebral and myocardial metabolic rate for glucose, regional measurement of cerebral blood volume, gated cardiac blood pools and capillary perfusion in brain and heart. Studies on patients with stroke and myocardial ischemia are also presented.
GATE Monte Carlo simulation of GE Discovery 600 and a uniformity phantom
NASA Astrophysics Data System (ADS)
Sheen, Heesoon; Im, Ki Chun; Choi, Yong; Shin, Hanback; Han, Youngyih; Chung, Kwangzoo; Cho, Junsang; Ahn, Sang Hee
2014-12-01
GATE (Geant4 Application Tomography Emission) Monte Carlo simulations have been successful in the application of emission tomography for precise modeling of various physical processes. Most previous studies on Monte Carlo simulations have only involved performance assessments using virtual phantoms. Although that allows the performance of simulated positron emission tomography (PET) to be evaluated, it does not reflect the reality of practical conditions. This restriction causes substantial drawbacks in GATE simulations of real situations. To overcome the described limitation and to provide a method to enable simulation research relevant to clinically important issues, we conducted a GATE simulation using real data from a scanner rather than a virtual phantom and evaluated the scanner is performance. For that purpose, the system and the geometry of a commercial GE PET/ CT (computed tomography) scanner, BGO-based Discovery 600 (D600), was developed for the first time. The performance of the modeled PET system was evaluated by using the National Electrical Manufacturers Association NEMA NU 2-2007 protocols and results were compared with those of the reference data. The sensitivity, scatter fraction, noise-equivalent count rate (NECR), and resolution were estimated by using the protocol of the NEMA NU2-2007. Sensitivities were 9.01 cps/kBq at 0 cm and 9.43 cps/kBq at 10 cm. Scatter fractions were 39.5%. The NECR peak was 89.7 kcps @ 14.7 kBq/cc. Resolutions were 4.8 mm in the transaxial plane and 5.9 mm in the axial plane at 1 cm, and 6.2 mm in the transaxial plane and 6.4 mm in the axial plane at 10 cm. The resolutions exceeded the limited value provided by the manufacturer. The uniformity phantom was simulated using the CT and the PET data. The output data in a ROOT format were converted and then reconstructed by using the C program and STIR (Software for Tomographic Image Reconstruction). The reconstructed images of the simulated uniformity phantom data had comparable quality even though improvement in the quality is still required. In conclusion, we have demonstrated a successful simulation of a PET system by using scanned data. In future studies, the parameters that alter the imaging conditions, such as patient movement and physiological change, need to be studied.
Development of an oximeter for neurology
NASA Astrophysics Data System (ADS)
Aleinik, A.; Serikbekova, Z.; Zhukova, N.; Zhukova, I.; Nikitina, M.
2016-06-01
Cerebral desaturation can occur during surgery manipulation, whereas other parameters vary insignificantly. Prolonged intervals of cerebral anoxia can cause serious damage to the nervous system. Commonly used method for measurement of cerebral blood flow uses invasive catheters. Other techniques include single photon emission computed tomography (SPECT), positron emission tomography (PET), magnetic resonance imaging (MRI). Tomographic methods frequently use isotope administration, that may result in anaphylactic reactions to contrast media and associated nerve diseases. Moreover, the high cost and the need for continuous monitoring make it difficult to apply these techniques in clinical practice. Cerebral oximetry is a method for measuring oxygen saturation using infrared spectrometry. Moreover reflection pulse oximetry can detect sudden changes in sympathetic tone. For this purpose the reflectance pulse oximeter for use in neurology is developed. Reflectance oximeter has a definite advantage as it can be used to measure oxygen saturation in any part of the body. Preliminary results indicate that the device has a good resolution and high reliability. Modern applied schematics have improved device characteristics compared with existing ones.
NASA Astrophysics Data System (ADS)
Thorek, Daniel L. J.; Ulmert, David; Diop, Ndeye-Fatou M.; Lupu, Mihaela E.; Doran, Michael G.; Huang, Ruimin; Abou, Diane S.; Larson, Steven M.; Grimm, Jan
2014-01-01
The invasion status of tumour-draining lymph nodes (LNs) is a critical indicator of cancer stage and is important for treatment planning. Clinicians currently use planar scintigraphy and single-photon emission computed tomography (SPECT) with 99mTc-radiocolloid to guide biopsy and resection of LNs. However, emerging multimodality approaches such as positron emission tomography combined with magnetic resonance imaging (PET/MRI) detect sites of disease with higher sensitivity and accuracy. Here we present a multimodal nanoparticle, 89Zr-ferumoxytol, for the enhanced detection of LNs with PET/MRI. For genuine translational potential, we leverage a clinical iron oxide formulation, altered with minimal modification for radiolabelling. Axillary drainage in naive mice and from healthy and tumour-bearing prostates was investigated. We demonstrate that 89Zr-ferumoxytol can be used for high-resolution tomographic studies of lymphatic drainage in preclinical disease models. This nanoparticle platform has significant translational potential to improve preoperative planning for nodal resection and tumour staging.
Mazon, D; Vezinet, D; Pacella, D; Moreau, D; Gabelieri, L; Romano, A; Malard, P; Mlynar, J; Masset, R; Lotte, P
2012-06-01
This paper is focused on the soft x-ray (SXR) tomography system setup at Tore Supra (DTOMOX) and the recent developments made to automatically get precise information about plasma features from inverted data. The first part describes the main aspects of the tomographic inversion optimization process. Several observations are made using this new tool and a set of shape factors is defined to help characterizing the emissivity field in a real-time perspective. The second part presents a detailed off-line analysis comparing the positions of the magnetic axis obtained from a magnetic equilibrium solver, and the maximum of the reconstructed emissivity field for ohmic and heated pulses. A systematic discrepancy of about 5 cm is found in both cases and it is shown that this discrepancy increases during sawtooth crashes. Finally, evidence of radially localized tungsten accumulation with an in-out asymmetry during a lower hybrid current drive pulse is provided to illustrate the DTOMOX capabilities for a precise observation of local phenomena.
Akoglu, Haldun; Akoglu, Ebru Unal; Evman, Serdar; Akoglu, Tayfun; Denizbasi, Arzu; Guneysel, Ozlem; Onur, Ozge; Onur, Ender
2012-10-01
Small pneumothoraces (PXs), which are not initially recognized with a chest x-ray film and diagnosed by a thoracic computed tomography (CT), are described as occult PX (OCPX). The objective of this study was to evaluate cervival spine (C-spine) and abdominal CT (ACT) for diagnosing OCPX and overt PX (OVPX). All patients with blunt trauma who presented consecutively to the emergency department during a 26-months period were included. Among all the chest CTs (CCTs) (6,155 patients) conducted during that period, 254 scans were confirmed to have a true PX. The findings in their C-spine CT and ACT were compared with the findings in CCTs. Among these patients, 254 had a diagnosis of PX confirmed with CCT. OCPXs were identified on the chest computed tomographic scan of 128 patients (70.3%), whereas OVPXs were evident in 54 patients (29.7%). Computed tomographic imaging of the C-spine was performed in 74% of patients with OCPX and 66.7% of patients with OVPX trauma. Only 45 (35.2%) cases of OCPX and 42 (77.8%) cases of OVPX were detected by C-spine CT. ACT was performed in almost all patients, and 121 (95.3%) of 127 of these correctly identified an existing OCPX. Sensitivity of C-spine CT and ACT was 35.1% and 96.5%, respectively; specificity was 100% and 100%, respectively. Almost all OCPXs, regardless of intrathoracic location, could be detected by ACT or by combining C-spine and abdominal computed tomographic screening for patients. If the junction of the first and second vertebra is used as the caudad extent, C-spine CT does not have sufficient power to diagnose more than a third of the cases. Diagnostic study, level III.
Rodriguez-Lorenzo, Andres; Audolfsson, Thorir; Wong, Corrine; Cheng, Angela; Arbique, Gary; Nowinski, Daniel; Rozen, Shai
2015-10-01
The aim of this study was to evaluate the contribution of a single unilateral facial vein in the venous outflow of total-face allograft using three-dimensional computed tomographic imaging techniques to further elucidate the mechanisms of venous complications following total-face transplant. Full-face soft-tissue flaps were harvested from fresh adult human cadavers. A single facial vein was identified and injected distally to the submandibular gland with a radiopaque contrast (barium sulfate/gelatin mixture) in every specimen. Following vascular injections, three-dimensional computed tomographic venographies of the faces were performed. Images were viewed using TeraRecon Software (Teracon, Inc., San Mateo, CA, USA) allowing analysis of the venous anatomy and perfusion in different facial subunits by observing radiopaque filling venous patterns. Three-dimensional computed tomographic venographies demonstrated a venous network with different degrees of perfusion in subunits of the face in relation to the facial vein injection side: 100% of ipsilateral and contralateral forehead units, 100% of ipsilateral and 75% of contralateral periorbital units, 100% of ipsilateral and 25% of contralateral cheek units, 100% of ipsilateral and 75% of contralateral nose units, 100% of ipsilateral and 75% of contralateral upper lip units, 100% of ipsilateral and 25% of contralateral lower lip units, and 50% of ipsilateral and 25% of contralateral chin units. Venographies of the full-face grafts revealed better perfusion in the ipsilateral hemifaces from the facial vein in comparison with the contralateral hemifaces. Reduced perfusion was observed mostly in the contralateral cheek unit and contralateral lower face including the lower lip and chin units. Copyright © 2015 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Hei, Matthew A.; Budzien, Scott A.; Dymond, Kenneth F.; Nicholas, Andrew C.; Paxton, Larry J.; Schaefer, Robert K.; Groves, Keith M.
2017-07-01
We present the Volume Emission Rate Tomography (VERT) technique for inverting satellite-based, multisensor limb and nadir measurements of atmospheric ultraviolet emission to create whole-orbit reconstructions of atmospheric volume emission rate. The VERT approach is more general than previous ionospheric tomography methods because it can reconstruct the volume emission rate field irrespective of the particular excitation mechanisms (e.g., radiative recombination, photoelectron impact excitation, and energetic particle precipitation in auroras); physical models are then applied to interpret the airglow. The technique was developed and tested using data from the Special Sensor Ultraviolet Limb Imager and Special Sensor Ultraviolet Spectrographic Imager instruments aboard the Defense Meteorological Satellite Program F-18 spacecraft and planned for use with upcoming remote sensing missions. The technique incorporates several features to optimize the tomographic solutions, such as the use of a nonnegative algorithm (Richardson-Lucy, RL) that explicitly accounts for the Poisson statistics inherent in optical measurements, capability to include extinction effects due to resonant scattering and absorption of the photons from the lines of sight, a pseudodiffusion-based regularization scheme implemented between iterations of the RL code to produce smoother solutions, and the capability to estimate error bars on the solutions. Tests using simulated atmospheric emissions verify that the technique performs well in a variety of situations, including daytime, nighttime, and even in the challenging terminator regions. Lastly, we consider ionospheric nightglow and validate reconstructions of the nighttime electron density against Advanced Research Project Agency (ARPA) Long-range Tracking and Identification Radar (ALTAIR) incoherent scatter radar data.
A phase1 study of stereotactic gene delivery of AAV2-NGF for Alzheimer's disease.
Rafii, Michael S; Baumann, Tiffany L; Bakay, Roy A E; Ostrove, Jeffrey M; Siffert, Joao; Fleisher, Adam S; Herzog, Christopher D; Barba, David; Pay, Mary; Salmon, David P; Chu, Yaping; Kordower, Jeffrey H; Bishop, Kathie; Keator, David; Potkin, Steven; Bartus, Raymond T
2014-09-01
Nerve growth factor (NGF) is an endogenous neurotrophic-factor protein with the potential to restore function and to protect degenerating cholinergic neurons in Alzheimer's disease (AD), but safe and effective delivery has proved unsuccessful. Gene transfer, combined with stereotactic surgery, offers a potential means to solve the long-standing delivery obstacles. An open-label clinical trial evaluated the safety and tolerability, and initial efficacy of three ascending doses of the genetically engineered gene-therapy vector adeno-associated virus serotype 2 delivering NGF (AAV2-NGF [CERE-110]). Ten subjects with AD received bilateral AAV2-NGF stereotactically into the nucleus basalis of Meynert. AAV2-NGF was safe and well-tolerated for 2 years. Positron emission tomographic imaging and neuropsychological testing showed no evidence of accelerated decline. Brain autopsy tissue confirmed long-term, targeted, gene-mediated NGF expression and bioactivity. This trial provides important evidence that bilateral stereotactic administration of AAV2-NGF to the nucleus basalis of Meynert is feasible, well-tolerated, and able to produce long-term, biologically active NGF expression, supporting the initiation of an ongoing multicenter, double-blind, sham-surgery-controlled trial. Copyright © 2014 The Alzheimer's Association. Published by Elsevier Inc. All rights reserved.
Characterization of an In-Beam PET Prototype for Proton Therapy With Different Target Compositions
NASA Astrophysics Data System (ADS)
Attanasi, Francesca; Belcari, Nicola; Moehrs, Sascha; Rosso, Valeria; Vecchio, Sara; Cirrone, G. A. Pablo; Cuttone, Giacomo; Lojacono, Piero; Romano, Francesco; Lanconelli, Nico; Del Guerra, Alberto
2010-06-01
At the University of Pisa, the DoPET (Dosimetry with a Positron Emission Tomograph) project has focused on the development and characterization of an ad hoc, scalable, dual-head PET prototype for in-beam treatment planning verification of the proton therapy. In this paper we report the first results obtained with our current prototype, consisting of two opposing lutetium yttrium orthosilicate (LYSO) detectors, each one covering an area of 4.5 × 4.5 cm2. We measured the β+-activation induced by 62 MeV proton beams at Catana facility (LNS, Catania, Italy) in several plastic phantoms. Experiments were performed to evaluate the possibility to extract accurate phantom geometrical information from the reconstructed PET images. The PET prototype proved its capability of locating small air cavities in homogeneous PMMA phantoms with a submillimetric accuracy and of distinguishing materials with different 16O and 12C content by back mapping phantom geometry through the separation of the isotope contributions. This could be very useful in the clinical practice as a tool to highlight anatomical or physiological organ variations among different treatment sessions and to discriminate different tissue types, thus providing feedbacks for the accuracy of dose deposition.
NASA Astrophysics Data System (ADS)
Hoi, Jennifer W.; Kim, Hyun K.; Khalil, Michael A.; Fong, Christopher J.; Marone, Alessandro; Shrikhande, Gautam; Hielscher, Andreas H.
2015-03-01
Dynamic optical tomographic imaging has shown promise in diagnosing and monitoring peripheral arterial disease (PAD), which affects 8 to 12 million in the United States. PAD is the narrowing of the arteries that supply blood to the lower extremities. Prolonged reduced blood flow to the foot leads to ulcers and gangrene, which makes placement of optical fibers for contact-based optical tomography systems difficult and cumbersome. Since many diabetic PAD patients have foot wounds, a non-contact interface is highly desirable. We present a novel non-contact dynamic continuous-wave optical tomographic imaging system that images the vasculature in the foot for evaluating PAD. The system images at up to 1Hz by delivering 2 wavelengths of light to the top of the foot at up to 20 source positions through collimated source fibers. Transmitted light is collected with an electron multiplying charge couple device (EMCCD) camera. We demonstrate that the system can resolve absorbers at various locations in a phantom study and show the system's first clinical 3D images of total hemoglobin changes in the foot during venous occlusion at the thigh. Our initial results indicate that this system is effective in capturing the vascular dynamics within the foot and can be used to diagnose and monitor treatment of PAD in diabetic patients.
Computer-aided interpretation approach for optical tomographic images
NASA Astrophysics Data System (ADS)
Klose, Christian D.; Klose, Alexander D.; Netz, Uwe J.; Scheel, Alexander K.; Beuthan, Jürgen; Hielscher, Andreas H.
2010-11-01
A computer-aided interpretation approach is proposed to detect rheumatic arthritis (RA) in human finger joints using optical tomographic images. The image interpretation method employs a classification algorithm that makes use of a so-called self-organizing mapping scheme to classify fingers as either affected or unaffected by RA. Unlike in previous studies, this allows for combining multiple image features, such as minimum and maximum values of the absorption coefficient for identifying affected and not affected joints. Classification performances obtained by the proposed method were evaluated in terms of sensitivity, specificity, Youden index, and mutual information. Different methods (i.e., clinical diagnostics, ultrasound imaging, magnet resonance imaging, and inspection of optical tomographic images), were used to produce ground truth benchmarks to determine the performance of image interpretations. Using data from 100 finger joints, findings suggest that some parameter combinations lead to higher sensitivities, while others to higher specificities when compared to single parameter classifications employed in previous studies. Maximum performances are reached when combining the minimum/maximum ratio of the absorption coefficient and image variance. In this case, sensitivities and specificities over 0.9 can be achieved. These values are much higher than values obtained when only single parameter classifications were used, where sensitivities and specificities remained well below 0.8.
The economic potential of CT scanners for hardwood sawmills
Donald G. Hodges; Walter C. Anderson; Charles W. McMillin
1990-01-01
Research has demonstrated that a knowledge of internal log defects prior to sawing could improve lumber value yields significantly. This study evaluated the potential economic returns from investments in computerized tomographic (CT) scanners to detect internal defects in hardwood logs at southern sawmills. The results indicate that such investments would be profitable...
USDA-ARS?s Scientific Manuscript database
There is growing use of hybrid catfish (Ictalurus punctatus ' X Ictalurus furcatus ') in commercial aquaculture to utilize hybrid vigour to improve production A conjoined twin specimen found during the course of production studies by the United States Department of Agriculture Catfish Genetic Resear...
Sun, Zhipeng; Fu, Kaiyuan; Zhang, Zuyan; Zhao, Yanping; Ma, Xuchen
2012-05-01
The aim of this study was to primarily investigate the usefulness of computerized tomographic (CT) fistulography in the diagnosis and management of branchial cleft fistulae and sinuses. Fifteen patients with confirmed branchial fistulae or sinuses who had undergone CT fistulography were included. The diagnoses were confirmed by clinical, radiologic, or histopathologic examinations. The internal openings, distribution, and neighboring relationship of the lesions presented by CT fistulography were analyzed to evaluate the usefulness in comparison with x-ray fistulography. Nine patients were diagnosed with first branchial fistulae or sinuses, 2 with second branchial fistulae, and 4 with third or fourth branchial fistulae. The presence and location of the lesions could be seen on x-ray fistulography. The distribution of the lesions, internal openings, and neighboring relationship with parotid gland, carotid sheath, and submandibular gland could be clearly demonstrated on CT cross-sectional or volume-rendering images. CT fistulography could provide valuable information and benefit surgical planning by demonstrating the courses of branchial anomalies in detail. Copyright © 2012 Elsevier Inc. All rights reserved.
Long-term efficacy of biomodeled polymethyl methacrylate implants for orbitofacial defects.
Groth, Michael J; Bhatnagar, Aparna; Clearihue, William J; Goldberg, Robert A; Douglas, Raymond S
2006-01-01
To report the long-term efficacy of custom polymethyl methacrylate implants using high-resolution computed tomographic modeling in the reconstruction of complex orbitofacial defects secondary to trauma. Nine patients with complex orbitofacial bone defects after trauma were evaluated for this retrospective, nonrandomized, noncomparative study. All the patients underwent reconstruction using custom, heat-cured polymethyl methacrylate implants. Patients were followed up postoperatively and evaluated for complications. Nine consecutive patients (5 men and 4 women) aged 28 to 63 years who underwent surgical reconstruction using prefabricated, heat-cured polymethyl methacrylate implants were included in the study. The interval between injury and presentation ranged from 1 month to 40 years. There were no significant complications, including infection, extrusion, or displacement of the implant. In all of the patients, wound healing was uneventful, with antibiotic drugs administered perioperatively. Mean follow-up was 4.3 years from the first visit (range, 6 months to 10 years). Computed tomographic biomodeled, prefabricated, heat-cured polymethyl methacrylate implants are well tolerated in the long term. Their advantages include customized design, long-term biocompatibility, and excellent aesthetic results.
Inspiratory and expiratory computed tomographic volumetry for lung volume reduction surgery.
Morimura, Yuki; Chen, Fengshi; Sonobe, Makoto; Date, Hiroshi
2013-06-01
Three-dimensional (3D) computed tomographic (CT) volumetry has been introduced into the field of thoracic surgery, and a combination of inspiratory and expiratory 3D-CT volumetry provides useful data on regional pulmonary function as well as the volume of individual lung lobes. We report herein a case of a 62-year-old man with severe emphysema who had undergone lung volume reduction surgery (LVRS) to assess this technique as a tool for the evaluation of regional lung function and volume before and after LVRS. His postoperative pulmonary function was maintained in good condition despite a gradual slight decrease 2 years after LVRS. This trend was also confirmed by a combination of inspiratory and expiratory 3D-CT volumetry. We confirm that a combination of inspiratory and expiratory 3D-CT volumetry might be effective for the preoperative assessment of LVRS in order to determine the amount of lung tissue to be resected as well as for postoperative evaluation. This novel technique could, therefore, be used more widely to assess local lung function.
Inspiratory and expiratory computed tomographic volumetry for lung volume reduction surgery
Morimura, Yuki; Chen, Fengshi; Sonobe, Makoto; Date, Hiroshi
2013-01-01
Three-dimensional (3D) computed tomographic (CT) volumetry has been introduced into the field of thoracic surgery, and a combination of inspiratory and expiratory 3D-CT volumetry provides useful data on regional pulmonary function as well as the volume of individual lung lobes. We report herein a case of a 62-year-old man with severe emphysema who had undergone lung volume reduction surgery (LVRS) to assess this technique as a tool for the evaluation of regional lung function and volume before and after LVRS. His postoperative pulmonary function was maintained in good condition despite a gradual slight decrease 2 years after LVRS. This trend was also confirmed by a combination of inspiratory and expiratory 3D-CT volumetry. We confirm that a combination of inspiratory and expiratory 3D-CT volumetry might be effective for the preoperative assessment of LVRS in order to determine the amount of lung tissue to be resected as well as for postoperative evaluation. This novel technique could, therefore, be used more widely to assess local lung function. PMID:23460599
NASA Astrophysics Data System (ADS)
Menendez, H. M.; Thurber, C. H.
2011-12-01
Eastern California's Long Valley Caldera (LVC) and the Mono-Inyo Crater volcanic systems have been active for the past ~3.6 million years. Long Valley is known to produce very large silicic eruptions, the last of which resulted in the formation of a 17 km by 32 km wide, east-west trending caldera. Relatively recent unrest began between 1978-1980 with five ML ≥ 5.7 non-double-couple (NDC) earthquakes and associated aftershock swarms. Similar shallow seismic swarms have continued south of the resurgent dome and beneath Mammoth Mountain, surrounding sites of increased CO2 gas emissions. Nearly two decades of increased volcanic activity led to the 1997 installation of a temporary three-component array of 69 seismometers. This network, deployed by the Durham University, the USGS, and Duke University, recorded over 4,000 high-frequency events from May to September. A local tomographic inversion of 283 events surrounding Mammoth Mountain yielded a velocity structure with low Vp and Vp/Vs anomalies at 2-3 km bsl beneath the resurgent dome and Casa Diablo hot springs. These anomalies were interpreted to be CO2 reservoirs (Foulger et al., 2003). Several teleseismic and regional tomography studies have also imaged low Vp anomalies beneath the caldera at ~5-15 km depth, interpreted to be the underlying magma reservoir (Dawson et al., 1990; Weiland et al., 1995; Thurber et al., 2009). This study aims to improve the resolution of the LVC regional velocity model by performing tomographic inversions using the local events from 1997 in conjunction with regional events recorded by the Northern California Seismic Network (NCSN) between 1980 and 2010 and available refraction data. Initial tomographic inversions reveal a low velocity zone at ~2 to 6 km depth beneath the caldera. This structure may simply represent the caldera fill. Further iterations and the incorporation of teleseismic data may better resolve the overall shape and size of the underlying magma reservoir.
Advanced Ionospheric Sensing using GROUP-C and LITES aboard the ISS
NASA Astrophysics Data System (ADS)
Budzien, S. A.; Stephan, A. W.; Chakrabarti, S.; Finn, S. C.; Cook, T.; Powell, S. P.; O'Hanlon, B.; Bishop, R. L.
2015-12-01
The GPS Radio Occultation and Ultraviolet Photometer Co-located (GROUP-C) and Limb-imaging Ionospheric and Thermospheric Extreme-ultraviolet Spectrograph (LITES) experiments are manifested for flight aboard the International Space Station (ISS) in 2016 as part of the Space Test Program Houston #5 payload. The two experiments provide technical development and risk-reduction for future DoD space weather sensors suitable for ionospheric specification, space situational awareness, and data products for global ionosphere assimilative models. In addition, the combined instrument complement of these two experiments offers a unique opportunity to study structures of the nighttime ionosphere. GROUP-C includes an advanced GPS receiver providing ionospheric electron density profiles and scintillation measurements and a high-sensitivity far-ultraviolet photometer measuring horizontal ionospheric gradients. LITES is an imaging spectrograph that spans 60-140 nm and will obtain high-cadence limb profiles of the ionosphere and thermosphere from 150-350 km altitude. In the nighttime ionosphere, recombination of O+ and electrons produces optically thin emissions at 91.1 and 135.6 nm that can be used to tomographically reconstruct the two-dimensional plasma distribution in the orbital plane below ISS altitudes. Ionospheric irregularities, such as plasma bubbles and blobs, are transient features of the low and middle latitude ionosphere with important implications for operational systems. Irregularity structures have been studied primarily using ground-based systems, though some spaced-based remote and in-situ sensing has been performed. An ionospheric observatory aboard the ISS would provide new capability to study low- and mid-latitude ionospheric structures on a global scale. By combining for the first time high-sensitivity in-track photometry, vertical ionospheric airglow spectrographic imagery, and recent advancements in UV tomography, high-fidelity tomographic reconstruction of nighttime structures can be performed from the ISS. We discuss the tomographic approach, simulated reconstructions, and value added by including complementary ground-based observations. Acknowledgements: This work is supported by NRL Work Unit 76-1C09-05.
New developments in multimodal clinical multiphoton tomography
NASA Astrophysics Data System (ADS)
König, Karsten
2011-03-01
80 years ago, the PhD student Maria Goeppert predicted in her thesis in Goettingen, Germany, two-photon effects. It took 30 years to prove her theory, and another three decades to realize the first two-photon microscope. With the beginning of this millennium, first clinical multiphoton tomographs started operation in research institutions, hospitals, and in the cosmetic industry. The multiphoton tomograph MPTflexTM with its miniaturized flexible scan head became the Prism-Award 2010 winner in the category Life Sciences. Multiphoton tomographs with its superior submicron spatial resolution can be upgraded to 5D imaging tools by adding spectral time-correlated single photon counting units. Furthermore, multimodal hybrid tomographs provide chemical fingerprinting and fast wide-field imaging. The world's first clinical CARS studies have been performed with a hybrid multimodal multiphoton tomograph in spring 2010. In particular, nonfluorescent lipids and water as well as mitochondrial fluorescent NAD(P)H, fluorescent elastin, keratin, and melanin as well as SHG-active collagen have been imaged in patients with dermatological disorders. Further multimodal approaches include the combination of multiphoton tomographs with low-resolution imaging tools such as ultrasound, optoacoustic, OCT, and dermoscopy systems. Multiphoton tomographs are currently employed in Australia, Japan, the US, and in several European countries for early diagnosis of skin cancer (malignant melanoma), optimization of treatment strategies (wound healing, dermatitis), and cosmetic research including long-term biosafety tests of ZnO sunscreen nanoparticles and the measurement of the stimulated biosynthesis of collagen by anti-ageing products.
Rose, Michael; Rubal, Bernard; Hulten, Edward; Slim, Jennifer N; Steel, Kevin; Furgerson, James L; Villines, Todd C
2014-01-01
Background: The correlation between normal cardiac chamber linear dimensions measured during retrospective coronary computed tomographic angiography as compared to transthoracic echocardiography using the American Society of Echocardiography guidelines is not well established. Methods: We performed a review from January 2005 to July 2011 to identify subjects with retrospective electrocardiogram-gated coronary computed tomographic angiography scans for chest pain and transthoracic echocardiography with normal cardiac structures performed within 90 days. Dimensions were manually calculated in both imaging modalities in accordance with the American Society of Echocardiography published guidelines. Left ventricular ejection fraction was calculated on echocardiography manually using the Simpson’s formula and by coronary computed tomographic angiography using the end-systolic and end-diastolic volumes. Results: We reviewed 532 studies, rejected 412 and had 120 cases for review with a median time between studies of 7 days (interquartile range (IQR25,75) = 0–22 days) with no correlation between the measurements made by coronary computed tomographic angiography and transthoracic echocardiography using Bland–Altman analysis. We generated coronary computed tomographic angiography cardiac dimension reference ranges for both genders for our population. Conclusion: Our findings represent a step towards generating cardiac chamber dimensions’ reference ranges for coronary computed tomographic angiography as compared to transthoracic echocardiography in patients with normal cardiac morphology and function using the American Society of Echocardiography guideline measurements that are commonly used by cardiologists. PMID:26770706
Elmaleh, D R; Fischman, A J; Tawakol, A; Zhu, A; Shoup, T M; Hoffmann, U; Brownell, A-L; Zamecnik, P C
2006-10-24
Diadenosine-5',5'''-P(1),P(4)-tetraphosphate (Ap(4)A) and its analog P(2),P(3)-monochloromethylene diadenosine-5',5'''-P(1),P(4)-tetraphosphate (AppCHClppA) are competitive inhibitors of adenosine diphosphate-induced platelet aggregation, which plays a central role in arterial thrombosis and plaque formation. In this study, we evaluate the imaging capabilities of positron-emission tomography (PET) with P(2),P(3)-[(18)F]monofluoromethylene diadenosine-5',5'''-P(1),P(4)-tetraphosphate ([(18)F]AppCHFppA) to detect atherosclerotic lesions in male New Zealand White rabbits. Three to six months after balloon injury to the aorta, the rabbits were injected with [(18)F]AppCHFppA, and microPET imaging showed rapid accumulation of this radiopharmaceutical in the atherosclerotic abdominal aorta, with lesions clearly visible 30 min after injection. Computed tomographic images were coregistered with PET images to improve delineation of aortoiliac tracer activity. Plaque macrophage density, quantified by immunostaining with RAM11 against rabbit macrophages, correlated with PET measurements of [(18)F]AppCHFppA uptake (r = 0.87, P < 0.0001), whereas smooth-muscle cell density, quantified by immunostaining with 1A4 against smooth muscle actin, did not. Biodistribution studies of [(18)F]AppCHFppA in normal rats indicated typical adenosine dinucleotide behavior with insignificant myocardial uptake and fast kidney clearance. The accumulation of [(18)F]AppCHFppA in macrophage-rich atherosclerotic plaques can be quantified noninvasively with PET. Hence, [(18)F]AppCHFppA holds promise for the noninvasive characterization of vascular inflammation.
Motion compensation using origin ensembles in awake small animal positron emission tomography
NASA Astrophysics Data System (ADS)
Gillam, John E.; Angelis, Georgios I.; Kyme, Andre Z.; Meikle, Steven R.
2017-02-01
In emission tomographic imaging, the stochastic origin ensembles algorithm provides unique information regarding the detected counts given the measured data. Precision in both voxel and region-wise parameters may be determined for a single data set based on the posterior distribution of the count density allowing uncertainty estimates to be allocated to quantitative measures. Uncertainty estimates are of particular importance in awake animal neurological and behavioral studies for which head motion, unique for each acquired data set, perturbs the measured data. Motion compensation can be conducted when rigid head pose is measured during the scan. However, errors in pose measurements used for compensation can degrade the data and hence quantitative outcomes. In this investigation motion compensation and detector resolution models were incorporated into the basic origin ensembles algorithm and an efficient approach to computation was developed. The approach was validated against maximum liklihood—expectation maximisation and tested using simulated data. The resultant algorithm was then used to analyse quantitative uncertainty in regional activity estimates arising from changes in pose measurement precision. Finally, the posterior covariance acquired from a single data set was used to describe correlations between regions of interest providing information about pose measurement precision that may be useful in system analysis and design. The investigation demonstrates the use of origin ensembles as a powerful framework for evaluating statistical uncertainty of voxel and regional estimates. While in this investigation rigid motion was considered in the context of awake animal PET, the extension to arbitrary motion may provide clinical utility where respiratory or cardiac motion perturb the measured data.
NASA Astrophysics Data System (ADS)
Lester, R.; Zhai, Y.; Corr, C.; Howard, J.
2016-02-01
This paper describes a coherence imaging system designed for spectroscopic Doppler measurements of ion light in a low-temperature (T e < 10 eV) helicon-produced argon plasma. Observation of the very small Doppler broadening of the Ar II 488 nm emission line requires very high spectral resolution, or equivalently, very large interferometric optical path delay (comparable with the coherence length of the emission line). For these polarization interferometers, this can only be achieved using large thicknesses (100 mm) of birefringent crystal. This poses special design challenges including the application of field-widening techniques and the development of passive thermal stabilization of the optical phase offset. We discuss the measurement principles and the optical design of these systems and present measurements of the line-integrated emissivity, and ion flow and ion temperatures along with tomographic reconstructions of the local values, for a cylindrical low temperature helicon discharge in a linear magnetized device with downstream magnetic mirror. Key results reveal a hollow edge-peaked temperature profile (central temperature ∼0.1 eV) and sheared rigid-body rotational flows and axial flows which are comparable with the ion thermal speed. The emission line brightness, ion temperature and azimuthal ion flows are all found to increase with increased mirror magnetic field strength.
Wiley, Clayton A.; Lopresti, Brian J.; Venneti, Sriram; Price, Julie; Klunk, William E.; DeKosky, Steven T.; Mathis, Chester A.
2009-01-01
Background Alzheimer disease (AD) is defined neuropathologically by the presence of neurofibrillary tangles and plaques associated with tau and β-amyloid protein deposition. The colocalization of microglia and β-amyloid plaques has been widely reported in pathological examination of AD and suggests that neuroinflammation may play a role in pathogenesis and/or progression. Because postmortem histopathological analyses are limited to single end-stage assessment, the time course and nature of this relationship are not well understood. Objective To image microglial activation and β-amyloid deposition in the brains of subjects with and without AD. Design, Setting, and Participants Using two carbon 11 ([11C])–labeled positron emission tomographic imaging agents, Pittsburgh Compound B (PiB) and (R)-PK11195, we examined the relationship between amyloid deposition and microglial activation in different stages of AD using 5 control subjects, 6 subjects diagnosed with mild cognitive impairment, and 6 patients with mild to moderate AD. Results Consistent with prior reports, subjects with a clinical diagnosis of probable AD showed significantly greater levels of [11C]PiB retention than control subjects, whereas patients with mild cognitive impairment spanned a range from control-like to AD-like levels of [11C]PiB retention. Additionally, 2 asymptomatic control subjects also exhibited evidence of elevated PiB retention in regions associated with the early emergence of plaques in AD and may represent prodromal cases of AD. We observed no differences in brain [11C](R)-PK11195 retention when subjects were grouped by clinical diagnosis or the presence or absence of β-amyloid pathological findings as indicated by analyses of [11C]PiB retention. Conclusions These findings suggest that either microglial activation is limited to later stages of severe AD or [11C](R)-PK11195 is too insensitive to detect the level of microglial activation associated with mild to moderate AD. PMID:19139300
NASA Astrophysics Data System (ADS)
Akolkar, A.; Petrasch, J.; Finck, S.; Rahmatian, N.
2018-02-01
An inverse analysis of the phosphor layer of a commercially available, conformally coated, white LED is done based on tomographic and spectrometric measurements. The aim is to determine the radiative transfer coefficients of the phosphor layer from the measurements of the finished device, with minimal assumptions regarding the composition of the phosphor layer. These results can be used for subsequent opto-thermal modelling and optimization of the device. For this purpose, multiple integrating sphere and gonioradiometric measurements are done to obtain statistical bounds on spectral radiometric values and angular color distributions for ten LEDs belonging to the same color bin of the product series. Tomographic measurements of the LED package are used to generate a tetrahedral grid of the 3D LED geometry. A radiative transfer model using Monte Carlo Ray Tracing in the tetrahedral grid is developed. Using a two-wavelength model consisting of a blue emission wavelength and a yellow, Stokes-shifted re-emission wavelength, the angular color distribution of the LED is simulated over wide ranges of the absorption and scattering coefficients of the phosphor layer, for the blue and yellow wavelengths. Using a two-step, iterative space search, combinations of the radiative transfer coefficients are obtained for which the simulations are consistent with the integrating sphere and gonioradiometric measurements. The results show an inverse relationship between the scattering and absorption coefficients of the phosphor layer for blue light. Scattering of yellow light acts as a distribution and loss mechanism for yellow light and affects the shape of the angular color distribution significantly, especially at larger viewing angles. The spread of feasible coefficients indicates that measured optical behavior of the LEDs may be reproduced using a range of combinations of radiative coefficients. Given that coefficients predicted by the Mie theory usually must be corrected in order to reproduce experimental results, these results indicate that a more complete model of radiative transfer in phosphor layers is required.
NASA Astrophysics Data System (ADS)
Fourmaux, Sylvain; Kieffer, Jean-Claude; Krol, Andrzej
2017-03-01
We are developing ultrahigh spatial resolution (FWHM < 2 μm) high-brilliance x-ray source for rapid in vivo tomographic microvasculature imaging micro-CT angiography (μCTA) in small animal models using optimized contrast agent. It exploits Laser Wakefield Accelerator (LWFA) betatron x-ray emission phenomenon. Ultrashort high-intensity laser pulse interacting with a supersonic gas jet produces an ion cavity ("bubble") in the plasma in the wake of the laser pulse. Electrons that are injected into this bubble gain energy, perform wiggler-like oscillations and generate burst of incoherent x-rays with characteristic duration time comparable to the laser pulse duration, continuous synchrotron-like spectral distribution that might extend to hundreds keV, very high brilliance, very small focal spot and highly directional emission in the cone-beam geometry. Such LWFA betatron x-ray source created in our lab produced 1021 -1023 photonsṡ shot-1ṡmrad-2ṡmm-2/0.1%bw with mean critical energy in the12-30 keV range. X-ray source size for a single laser shot was FWHM=1.7 μm x-ray beam divergence 20-30 mrad, and effective focal spot size for multiple shots FWHM= 2 μm. Projection images of simple phantoms and complex biological objects including insects and mice were obtained in single laser shots. We conclude that ultrahigh spatial resolution μCTA (FWHM 2 μm) requiring thousands of projection images could be accomplished using LWFA betatron x-ray radiation in approximately 40 s with our existing 220 TW laser and sub seconds with next generation of ultrafast lasers and x-ray detectors, as opposed to several hours required using conventional microfocal x-ray tubes. Thus, sub second ultrahigh resolution in vivo microtomographic microvasculature imaging (in both absorption and phase contrast mode) in small animal models of cancer and vascular diseases will be feasible with LWFA betatron x-ray source.
Bühler, M; Fürst, A; Lewis, F I; Kummer, M; Ohlerth, S
2014-07-01
Computed tomographic (CT) studies evaluating the relevance of individual CT features of apical infection in maxillary cheek teeth are lacking. To study the prevalence and relationship of single CT features in horses with and without clinical evidence of apical infection in maxillary cheek teeth. Retrospective case-control study. Multislice CT scans of the head of 49 horses were evaluated retrospectively. Changes of the infundibulum, pulp, root, lamina dura, periodontal space and alveolar bone in maxillary cheek teeth were recorded. Single CT changes were much more prevalent in the 28 horses with clinical signs. However, infundibular changes and a nondetectable lamina dura were also common in the 21 horses without clinical evidence of apical infection. Computed tomographic abnormalities of the pulp, root, periapical bone and periodontal space and the presence of a tooth fracture were significantly related. Infundibular changes were not associated with other CT signs of apical infection. Although nondetectable lamina dura was the most frequent CT change in all teeth in both studied groups, it was most commonly a solitary feature in otherwise normal teeth. Apical infections, defined as ≥3 CT changes, occurred mainly in the 108/208, 109/209 and 110/210 (Triadan numbers) and were found only in horses with clinical evidence of apical infection, except in one horse without clinical signs that had one affected root. Combined CT changes of the pulp, root, lamina dura, periapical bone and periodontal space and the presence of a tooth fracture appear to be reliable features to diagnose apical infection in maxillary cheek teeth. As a solitary feature, a nondetectable lamina dura should be interpreted cautiously and may even be considered normal due to its minor thickness and/or too low resolution of the imaging modality. © 2013 EVJ Ltd.
NASA Astrophysics Data System (ADS)
Edjlali, Ehsan; Bérubé-Lauzière, Yves
2018-01-01
We present the first Lq -Lp optimization scheme for fluorescence tomographic imaging. This is then applied to small animal imaging. Fluorescence tomography is an ill-posed, and in full generality, a nonlinear problem that seeks to image the 3D concentration distribution of a fluorescent agent inside a biological tissue. Standard candidates for regularization to deal with the ill-posedness of the image reconstruction problem include L1 and L2 regularization. In this work, a general Lq -Lp regularization framework (Lq discrepancy function - Lp regularization term) is introduced for fluorescence tomographic imaging. A method to calculate the gradient for this general framework is developed which allows evaluating the performance of different cost functions/regularization schemes in solving the fluorescence tomographic problem. The simplified spherical harmonics approximation is used to accurately model light propagation inside the tissue. Furthermore, a multigrid mesh is utilized to decrease the dimension of the inverse problem and reduce the computational cost of the solution. The inverse problem is solved iteratively using an lm-BFGS quasi-Newton optimization method. The simulations are performed under different scenarios of noisy measurements. These are carried out on the Digimouse numerical mouse model with the kidney being the target organ. The evaluation of the reconstructed images is performed both qualitatively and quantitatively using several metrics including QR, RMSE, CNR, and TVE under rigorous conditions. The best reconstruction results under different scenarios are obtained with an L1.5 -L1 scheme with premature termination of the optimization process. This is in contrast to approaches commonly found in the literature relying on L2 -L2 schemes.
NASA Astrophysics Data System (ADS)
Yuan, Fusong; Lv, Peijun; Yang, Huifang; Wang, Yong; Sun, Yuchun
2015-07-01
Objectives: Based on the pixel gray value measurements, establish a beam-hardening artifacts index of the cone-beam CT tomographic image, and preliminarily evaluate its applicability. Methods: The 5mm-diameter metal ball and resin ball were fixed on the light-cured resin base plate respectively, while four vitro molars were fixed above and below the ball, on the left and right respectively, which have 10mm distance with the metal ball. Then, cone beam CT was used to scan the fixed base plate twice. The same layer tomographic images were selected from the two data and imported into the Photoshop software. The circle boundary was built through the determination of the center and radius of the circle, according to the artifact-free images section. Grayscale measurement tools were used to measure the internal boundary gray value G0, gray value G1 and G2 of 1mm and 20mm artifacts outside the circular boundary, the length L1 of the arc with artifacts in the circular boundary, the circumference L2. Hardening artifacts index was set A = (G1 / G0) * 0.5 + (G2 / G1) * 0.4 + (L2 / L1) * 0.1. Then, the A values of metal and resin materials were calculated respectively. Results: The A value of cobalt-chromium alloy material is 1, and resin material is 0. Conclusion: The A value reflects comprehensively the three factors of hardening artifacts influencing normal oral tissue image sharpness of cone beam CT. The three factors include relative gray value, the decay rate and range of artifacts.
Nakanishi, Rine; Baskaran, Lohendran; Gransar, Heidi; Budoff, Matthew J; Achenbach, Stephan; Al-Mallah, Mouaz; Cademartiri, Filippo; Callister, Tracy Q; Chang, Hyuk-Jae; Chinnaiyan, Kavitha; Chow, Benjamin J W; DeLago, Augustin; Hadamitzky, Martin; Hausleiter, Joerg; Cury, Ricardo; Feuchtner, Gudrun; Kim, Yong-Jin; Leipsic, Jonathon; Kaufmann, Philipp A; Maffei, Erica; Raff, Gilbert; Shaw, Leslee J; Villines, Todd C; Dunning, Allison; Marques, Hugo; Pontone, Gianluca; Andreini, Daniele; Rubinshtein, Ronen; Bax, Jeroen; Jones, Erica; Hindoyan, Niree; Gomez, Millie; Lin, Fay Y; Min, James K; Berman, Daniel S
2017-08-01
Hypertension is an atherosclerosis factor and is associated with cardiovascular risk. We investigated the relationship between hypertension and the presence, extent, and severity of coronary atherosclerosis in coronary computed tomographic angiography and cardiac events risk. Of 17 181 patients enrolled in the CONFIRM registry (Coronary CT Angiography Evaluation for Clinical Outcomes: An International Multicenter Registry) who underwent ≥64-detector row coronary computed tomographic angiography, we identified 14 803 patients without known coronary artery disease. Of these, 1434 hypertensive patients were matched to 1434 patients without hypertension. Major adverse cardiac events risk of hypertension and non-hypertensive patients was evaluated with Cox proportional hazards models. The prognostic associations between hypertension and no-hypertension with increasing degree of coronary stenosis severity (nonobstructive or obstructive ≥50%) and extent of coronary artery disease (segment involvement score of 1-5, >5) was also assessed. Hypertension patients less commonly had no coronary atherosclerosis and more commonly had nonobstructive and 1-, 2-, and 3-vessel disease than the no-hypertension group. During a mean follow-up of 5.2±1.2 years, 180 patients experienced cardiac events, with 104 (2.0%) occurring in the hypertension group and 76 (1.5%) occurring in the no-hypertension group (hazard ratios, 1.4; 95% confidence intervals, 1.0-1.9). Compared with no-hypertension patients without coronary atherosclerosis, hypertension patients with no coronary atherosclerosis and obstructive coronary disease tended to have higher risk of cardiac events. Similar trends were observed with respect to extent of coronary artery disease. Compared with no-hypertension patients, hypertensive patients have increased presence, extent, and severity of coronary atherosclerosis and tend to have an increase in major adverse cardiac events. © 2017 American Heart Association, Inc.
Computed Tomographic Morphometry of the Internal Anatomy of Mandibular Second Primary Molars.
Kurthukoti, Ameet J; Sharma, Pranjal; Swamy, Dinesh Francis; Shashidara, R; Swamy, Elaine Barretto
2015-01-01
Need for the study: The most important procedure for a successful endodontic treatment is the cleaning and shaping of the canal system. Understanding the internal anatomy of teeth provides valuable information to the clinician that would help him achieve higher clinical success during endodontic therapy. To evaluate by computed tomography-the internal anatomy of mandibular second primary molars with respect to the number of canals, cross-sectional shape of canals, cross-sectional area of canals and the root dentin thickness. A total of 31 mandibular second primary molars were subjected to computed-tomographic evaluation in the transverse plane, after mounting them in a prefabricated template. The images, thus, obtained were analyzed using De-winter Bio-wizard® software. All the samples demonstrated two canals in the mesial root, while majority of the samples (65.48%) demonstrated two canals in the distal root. The cross-sectional images of the mesial canals demonstrated a round shape, while the distal canals demonstrated an irregular shape. The root dentin thickness was highly reduced on the distal aspect of mesial and mesial aspect of distal canals. The mandibular second primary molars demonstrated wide variation and complexities in their internal anatomy. A thorough understanding of the complexity of the root canal system is essential for understanding the principles and problems of shaping and cleaning, determining the apical limits and dimensions of canal preparations, and for performing successful endodontic procedures. How to cite this article: Kurthukoti AJ, Sharma P, Swamy DF, Shashidara R, Swamy EB. Computed Tomographic Morphometry of the Internal Anatomy of Mandibular Second Primary Molars. Int J Clin Pediatr Dent 2015;8(3):202-207.
Computed Tomographic Morphometry of the Internal Anatomy of Mandibular Second Primary Molars
Sharma, Pranjal; Swamy, Dinesh Francis; Shashidara, R; Swamy, Elaine Barretto
2015-01-01
ABSTRACT Need for the study: The most important procedure for a successful endodontic treatment is the cleaning and shaping of the canal system. Understanding the internal anatomy of teeth provides valuable information to the clinician that would help him achieve higher clinical success during endodontic therapy. Aims: To evaluate by computed tomography—the internal anatomy of mandibular second primary molars with respect to the number of canals, cross-sectional shape of canals, cross-sectional area of canals and the root dentin thickness. Materials and methods: A total of 31 mandibular second primary molars were subjected to computed-tomographic evaluation in the transverse plane, after mounting them in a prefabricated template. The images, thus, obtained were analyzed using De-winter Bio-wizard® software. Results: All the samples demonstrated two canals in the mesial root, while majority of the samples (65.48%) demonstrated two canals in the distal root. The cross-sectional images of the mesial canals demonstrated a round shape, while the distal canals demonstrated an irregular shape. The root dentin thickness was highly reduced on the distal aspect of mesial and mesial aspect of distal canals. Conclusion: The mandibular second primary molars demonstrated wide variation and complexities in their internal anatomy. A thorough understanding of the complexity of the root canal system is essential for understanding the principles and problems of shaping and cleaning, determining the apical limits and dimensions of canal preparations, and for performing successful endodontic procedures. How to cite this article: Kurthukoti AJ, Sharma P, Swamy DF, Shashidara R, Swamy EB. Computed Tomographic Morphometry of the Internal Anatomy of Mandibular Second Primary Molars. Int J Clin Pediatr Dent 2015;8(3):202-207. PMID:26628855
NASA Astrophysics Data System (ADS)
Thampi, Smitha V.; Yamamoto, Mamoru
2010-03-01
A chain of newly designed GNU (GNU is not UNIX) Radio Beacon Receivers (GRBR) has recently been established over Japan, primarily for tomographic imaging of the ionosphere over this region. Receivers installed at Shionomisaki (33.45°N, 135.8°E), Shigaraki (34.8°N, 136.1°E), and Fukui (36°N, 136°E) continuously track low earth orbiting satellites (LEOS), mainly OSCAR, Cosmos, and FORMOSAT-3/COSMIC, to obtain simultaneous total electron content (TEC) data from these three locations, which are then used for the tomographic reconstruction of ionospheric electron densities. This is the first GRBR network established for TEC observations, and the first beacon-based tomographic imaging in Japanese longitudes. The first tomographic images revealed the temporal evolution with all of the major features in the ionospheric electron density distribution over Japan. A comparison of the tomographically reconstructed electron densities with the ƒ o F 2 data from Kokubunji (35°N, 139°E) revealed that there was good agreement between the datasets. These first results show the potential of GRBR and its network for making continuous, unattended ionospheric TEC measurements and for tomographic imaging of the ionosphere.
Kim, Jung-Sun; Ha, Jinyong; Kim, Byeong-Keuk; Shin, Dong-Ho; Ko, Young-Guk; Choi, Donghoon; Jang, Yangsoo; Hong, Myeong-Ki
2014-06-01
This study sought to evaluate the relationship between post-stent strut apposition and follow-up strut coverage using contour plot optical coherence tomographic analysis. Tracking the fate of interested regions of struts at different time points has not been investigated. Post-intervention and 6-month follow-up optical coherence tomographic evaluations were performed in 82 patients treated with biolimus- (n = 37) or sirolimus-eluting stents (n = 45). Post-stent apposition was classified as embedded, apposed, or malapposed. For volumetric stent evaluation, the post-intervention strut-artery distance and the neointimal thickness at follow-up were measured as a function of the circumferential arc length and longitudinal stent length. Computer-generated contour plots of the strut-artery distance and neointimal thickness were compared. The percentages of embedded and malapposed struts after intervention were 1.8% (Interquartile range [IQR]: 0.6% to 6.2%) and 2.3% (IQR: 0.5% to 5.2%), respectively. The percentages of uncovered and malapposed struts at 6 months were 16.0% (IQR: 7.4% to 33.3%) and 0% (IQR: 0% to 0.7%), respectively. The percentage of uncovered struts at 6 months varied significantly with post-stent strut apposition (0% [IQR: 0% to 11.4%] in embedded, 16.3% [IQR: 8.1% to 31.3%] in apposed, and 26.8% [IQR: 0% to 56.3%] in malapposed, p < 0.001 for all pairwise comparisons). In lesions without tissue prolapse, embedded struts were all covered (100% covered struts) compared with those with tissue prolapse (76.8% covered, p < 0.001). The optical coherence tomography-guided optimization of stent strut apposition enhances strut coverage at follow-up. This comprehensive method for evaluating strut apposition may provide more useful information to understanding the serial changes in strut coverage. (Neointimal Coverage After Implantation of Biolimus Eluting Stent With Biodegradable Polymer: Optical Coherence Tomographic Assessment According to the Treatment of Dyslipidemia and Hypertension and the Types of Implanted Drug-Eluting Stents; NCT01502904). Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Boxx, I.; Carter, C. D.; Meier, W.
2014-08-01
Tomographic particle image velocimetry (tomographic-PIV) is a recently developed measurement technique used to acquire volumetric velocity field data in liquid and gaseous flows. The technique relies on line-of-sight reconstruction of the rays between a 3D particle distribution and a multi-camera imaging system. In a turbulent flame, however, index-of-refraction variations resulting from local heat-release may inhibit reconstruction and thereby render the technique infeasible. The objective of this study was to test the efficacy of tomographic-PIV in a turbulent flame. An additional goal was to determine the feasibility of acquiring usable tomographic-PIV measurements in a turbulent flame at multi-kHz acquisition rates with current-generation laser and camera technology. To this end, a setup consisting of four complementary metal oxide semiconductor cameras and a dual-cavity Nd:YAG laser was implemented to test the technique in a lifted turbulent jet flame. While the cameras were capable of kHz-rate image acquisition, the laser operated at a pulse repetition rate of only 10 Hz. However, use of this laser allowed exploration of the required pulse energy and thus power for a kHz-rate system. The imaged region was 29 × 28 × 2.7 mm in size. The tomographic reconstruction of the 3D particle distributions was accomplished using the multiplicative algebraic reconstruction technique. The results indicate that volumetric velocimetry via tomographic-PIV is feasible with pulse energies of 25 mJ, which is within the capability of current-generation kHz-rate diode-pumped solid-state lasers.
Large-scale tomographic particle image velocimetry using helium-filled soap bubbles
NASA Astrophysics Data System (ADS)
Kühn, Matthias; Ehrenfried, Klaus; Bosbach, Johannes; Wagner, Claus
2011-04-01
To measure large-scale flow structures in air, a tomographic particle image velocimetry (tomographic PIV) system for measurement volumes of the order of one cubic metre is developed, which employs helium-filled soap bubbles (HFSBs) as tracer particles. The technique has several specific characteristics compared to most conventional tomographic PIV systems, which are usually applied to small measurement volumes. One of them is spot lights on the HFSB tracers, which slightly change their position, when the direction of observation is altered. Further issues are the large particle to voxel ratio and the short focal length of the used camera lenses, which result in a noticeable variation of the magnification factor in volume depth direction. Taking the specific characteristics of the HFSBs into account, the feasibility of our large-scale tomographic PIV system is demonstrated by showing that the calibration errors can be reduced down to 0.1 pixels as required. Further, an accurate and fast implementation of the multiplicative algebraic reconstruction technique, which calculates the weighting coefficients when needed instead of storing them, is discussed. The tomographic PIV system is applied to measure forced convection in a convection cell at a Reynolds number of 530 based on the inlet channel height and the mean inlet velocity. The size of the measurement volume and the interrogation volumes amount to 750 mm × 450 mm × 165 mm and 48 mm × 48 mm × 24 mm, respectively. Validation of the tomographic PIV technique employing HFSBs is further provided by comparing profiles of the mean velocity and of the root mean square velocity fluctuations to respective planar PIV data.
Progress In The Development Of A Tomographic SPECT System For Online Dosimetry In BNCT
DOE Office of Scientific and Technical Information (OSTI.GOV)
Minsky, D. M.; Kreiner, A. J.; ECyT, UNSAM, M. de Irigoyen 3100
2010-08-04
In boron neutron capture therapy (BNCT) the delivered dose to the patient depends both on the neutron beam characteristics and on the {sup 10}B body distribution which, in turn, is governed by the tumor specificity of the {sup 10}B drug-carrier. BNCT dosimetry is a complex matter due to the several interactions that neutrons can undergo with the different nuclei present in tissue. However the boron capture reaction {sup 10}B(n,{alpha}){sup 7}Li accounts for about 80 % of the total dose in a tumor with 40 ppm in {sup 10}B concentration. Present dosimetric methods are indirect, based on drug biodistribution statistical datamore » and subjected to inter and intra-patient variability. In order to overcome the consequences of the concomitant high dosimetric uncertainties, we propose a SPECT (Single Photon Emission Tomography) approach based on the detection of the prompt gamma-ray (478 keV) emitted in 94 % of the cases from {sup 7}Li. For this purpose we designed, built and tested a prototype based on LaBr{sub 3}(Ce) scintillators. Measurements on a head and tumor phantom were performed in the accelerator-based BNCT facility of the University of Birmingham (UK). They result in the first tomographic image of the 10B capture distribution obtained in a BNCT facility.« less
Tomographic digital subtraction angiography for lung perfusion estimation in rodents.
Badea, Cristian T; Hedlund, Laurence W; De Lin, Ming; Mackel, Julie S Boslego; Samei, Ehsan; Johnson, G Allan
2007-05-01
In vivo measurements of perfusion present a challenge to existing small animal imaging techniques such as magnetic resonance microscopy, micro computed tomography, micro positron emission tomography, and microSPECT, due to combined requirements for high spatial and temporal resolution. We demonstrate the use of tomographic digital subtraction angiography (TDSA) for estimation of perfusion in small animals. TDSA augments conventional digital subtraction angiography (DSA) by providing three-dimensional spatial information using tomosynthesis algorithms. TDSA is based on the novel paradigm that the same time density curves can be reproduced in a number of consecutive injections of microL volumes of contrast at a series of different angles of rotation. The capabilities of TDSA are established in studies on lung perfusion in rats. Using an imaging system developed in-house, we acquired data for four-dimensional (4D) imaging with temporal resolution of 140 ms, in-plane spatial resolution of 100 microm, and slice thickness on the order of millimeters. Based on a structured experimental approach, we optimized TDSA imaging providing a good trade-off between slice thickness, the number of injections, contrast to noise, and immunity to artifacts. Both DSA and TDSA images were used to create parametric maps of perfusion. TDSA imaging has potential application in a number of areas where functional perfusion measurements in 4D can provide valuable insight into animal models of disease and response to therapeutics.
Performance Evaluation and Initial Clinical Test of the Positron Emission Mammography System (PEMi)
NASA Astrophysics Data System (ADS)
Li, Lin; Gu, Xiao-Yue; Li, Dao-Wu; Huang, Xian-Chao; Chai, Pei; Feng, Bao-Tong; Wang, Pei-Lin; Yun, Ming-Kai; Dai, Dong; Zhang, Zhi-Ming; Yin, Peng-Fei; Xu, Wen-Gui; Wei, Long
2015-10-01
A new polygon positron emission mammography imaging system (PEMi) was developed in 2009 by the Institute of High Energy Physics, Chinese Academy of Sciences. PEMi is constructed in a polygon structure with lutetium yttrium orthosilicate crystal arrays mounted on a position-sensitive photomultiplier. The system consists of 64 blocks and each block is arranged in 16 ×16 crystal arrays with a pixel size of 1.9 ×1.9 ×15 mm. The diameter of the detector ring is 166 mm, and the axial length is 128 mm. The transaxial field of view of PEMi is 110 mm. The goal of the initial study was to test PEMi's performance and the clinical imaging ability with a small group of selected subjects. The detectors have a measured intrinsic spatial resolution averaging 1.67 mm. The axial and tangential resolution remained under 2.5-mm full width at half maximum within the central 5-cm diameter of the field of view. The hot rods with a diameter of 1.7 mm can be clearly identified, and the structure of the region containing 1.35-mm diameter rods can also be observed. Using a 6-ns coincidence timing window and a 360 660-keV energy window, the peak sensitivity of the tomograph is 6.88%. The noise-equivalent count rate peak is 110 766 cps for a breast-like cylindrical phantom of 100 mm in diameter at an activity concentration of 0.03 MBq/cc. The recovery coefficients ranged from 0.21 to 0.85 for rods between 1 mm and 5 mm in the image-quality phantom. The reconstructed image resolution achieved an improvement compared with whole-body positron emission tomography (PET), which might reduce the lower threshold on detectable lesion size. Example patient images demonstrate that PEMi is clinically feasible. And more detailed structure information was obtained with PEMi than with the whole-body PET imaging.
USDA-ARS?s Scientific Manuscript database
Canola oil-carnauba wax oleogels were evaluated as a replacement for shortening in a baked cake system. The use of oleogels produced cake batters with a lower pseudoplastic property and also contributed to their viscous nature. The shortening replacement with oleogels at up to 50% was effective in m...
NASA Astrophysics Data System (ADS)
He, Chuansong; Santosh, M.
2018-05-01
The Tianshan orogenic belt, Junggar terrane and Altai terrane are located at the southwestern part of the Central Asian Orogenic Belt (CAOB). Here, we investigate the velocity structure beneath the Xinjiang region in NW China, which includes the Tarim terrane, Tianshan orogenic belt, Junggar terrane and Altai terrane with a view to evaluate the mantle dynamics based on teleseismic data recorded by 103 seismic stations. Our tomographic results show both high and low velocity perturbations beneath the Tianshan orogenic belt. We suggest that the high velocity perturbations beneath this orogenic belt might represent the northward subducted lithosphere of the Tarim Basin and the southward subducted lithosphere of the Junggar Basin. The low velocity structure beneath the Tianshan orogenic belt might represent asthenosphere upwelling that triggered the extensive magmatism which contributed to rebuilding of the Tianshan orogenic belt.
A tomographic technique for aerodynamics at transonic speeds
NASA Technical Reports Server (NTRS)
Lee, G.
1985-01-01
Computer aided tomography (CAT) provides a means of noninvasively measuring the air density distribution around an aerodynamic model. This technique is global in that a large portion of the flow field can be measured. A test of the applicability of CAT to transonic velocities was studied. A hemispherical-nose cylinder afterbody model was tested at a Mach number of 0.8 with a new laser holographic interferometer at the 2- by 2-Foot Transonic Wind Tunnel. Holograms of the flow field were taken and were reconstructed into interferograms. The fringe distribution (a measure of the local densities) was digitized for subsequent data reduction. A computer program based on the Fourier-transform technique was developed to convert the fringe distribution into three-dimensional densities around the model. Theoretical aerodynamic densities were calculated for evaluating and assessing the accuracy of the data obtained from the tomographic method.
Miller, Nathaniel; Lizarralde, Daniel
2016-01-01
Effects of serpentine-filled fault zones on seismic wave propagation in the upper mantle at the outer rise of subduction zones are evaluated using acoustic wave propagation models. Modeled wave speeds depend on azimuth, with slowest speeds in the fault-normal direction. Propagation is fastest along faults, but, for fault widths on the order of the seismic wavelength, apparent wave speeds in this direction depend on frequency. For the 5–12 Hz Pn arrivals used in tomographic studies, joint-parallel wavefronts are slowed by joints. This delay can account for the slowing seen in tomographic images of the outer rise upper mantle. At the Middle America Trench, confining serpentine to fault zones, as opposed to a uniform distribution, reduces estimates of bulk upper mantle hydration from ~3.5 wt % to as low as 0.33 wt % H2O.
3D electron tomography of pretreated biomass informs atomic modeling of cellulose microfibrils.
Ciesielski, Peter N; Matthews, James F; Tucker, Melvin P; Beckham, Gregg T; Crowley, Michael F; Himmel, Michael E; Donohoe, Bryon S
2013-09-24
Fundamental insights into the macromolecular architecture of plant cell walls will elucidate new structure-property relationships and facilitate optimization of catalytic processes that produce fuels and chemicals from biomass. Here we introduce computational methodology to extract nanoscale geometry of cellulose microfibrils within thermochemically treated biomass directly from electron tomographic data sets. We quantitatively compare the cell wall nanostructure in corn stover following two leading pretreatment strategies: dilute acid with iron sulfate co-catalyst and ammonia fiber expansion (AFEX). Computational analysis of the tomographic data is used to extract mathematical descriptions for longitudinal axes of cellulose microfibrils from which we calculate their nanoscale curvature. These nanostructural measurements are used to inform the construction of atomistic models that exhibit features of cellulose within real, process-relevant biomass. By computational evaluation of these atomic models, we propose relationships between the crystal structure of cellulose Iβ and the nanoscale geometry of cellulose microfibrils.
Condylar repositioning using centric relation bite in bimaxillary surgery
Lee, Chang-Youn; Jang, Chang-Su; Kim, Ju-Won; Kim, Jwa-Young
2013-01-01
Objective The purpose of this study was to evaluate displacement of the mandibular condyle after orthognathic surgery using a condylar-repositioning device. Methods The patient group comprised 20 adults who underwent bimaxillary surgery between August 2008 and July 2011. The degree of condylar displacement was measured by pre- and postoperative tomographic analysis using centric relation bite and a wire during surgery. A survey assessing temporomandibular joint (TMJ) sound, pain, and locking was performed. The 20 tomographs and surveys were analyzed using the Wilcoxon signed-rank test and McNemar's test, respectively. Results No significant changes were observed in the anterior, superior, or posterior joint space of the TMJ (p > 0.05). In addition, no significant change was observed in TMJ sound (p > 0.05). However, TMJ pain and locking both decreased significantly after surgery (p < 0.05). Conclusions Due to its simplicity, this method may be feasible and useful for repositioning condyles. PMID:23671832
TOMOGRAPHIC MORPHOLOGICAL STUDY OF THE CRANIUM AND ITS CORRELATION WITH CRANIAL HALO USE IN ADULTS
ALMEIDA, TIAGO FERREIRA DE; CHARAFEDDINE, HOMAR TOLEDO; ARAÚJO, FERNANDO FLORES DE; CRISTANTE, ALEXANDRE FOGAÇA; MARCON, RAPHAEL MARTUS; LETAIF, OLAVO BIRAGHI
2017-01-01
ABSTRACT Objective: To evaluate using tomographic study the thickness of the cranial board at the insertions points of the cranial halo pins in adults Methods: This is a retrospective, cross-sectional, descriptive analysis of Computed Tomography (CT) scans of adult patients' crania. The study included adults between 20 and 50 years without cranial abnormalities. We excluded any exam with cranial abnormalities Results: We analyzed 50 CT scans, including 27 men and 23 women, at the original insertion points and alternative points (1 and 2 cm above the frontal and parietal bones). The average values were 7.4333 mm in the frontal bone and 6.0290 mm in the parietal bone Conclusion: There was no statistically significant difference between the classical and alternative points, making room for alternative fixings and safer introduction of the pins, if necessary.Level of Evidence II, Retrospective Study. PMID:28642643
DOE Office of Scientific and Technical Information (OSTI.GOV)
PELT, DANIEL
2017-04-21
Small Python package to compute tomographic reconstructions using a reconstruction method published in: Pelt, D.M., & De Andrade, V. (2017). Improved tomographic reconstruction of large-scale real-world data by filter optimization. Advanced Structural and Chemical Imaging 2: 17; and Pelt, D. M., & Batenburg, K. J. (2015). Accurately approximating algebraic tomographic reconstruction by filtered backprojection. In Proceedings of The 13th International Meeting on Fully Three-Dimensional Image Reconstruction in Radiology and Nuclear Medicine (pp. 158-161).
Simulation results of a veto counter for the ClearPEM
NASA Astrophysics Data System (ADS)
Trummer, J.; Auffray, E.; Lecoq, P.
2009-04-01
The Crystal Clear Collaboration (CCC) has built a prototype of a novel positron emission tomograph dedicated to functional breast imaging, the ClearPEM. The ClearPEM uses the common radio pharmaceutical FDG for imaging cancer. As FDG is a rather non-specific radio tracer, it accumulates not only in cancer cells but in all cells with a high energy consumption, such as the heart and liver. This fact poses a problem especially in breast imaging, where the vicinity of the heart and other organs to the breast leads to a high background noise level in the scanner. In this work, a veto counter to reduce the background is described. Different configurations and their effectiveness were studied using the GATE simulation package.
NASA Astrophysics Data System (ADS)
Huh, C.; Bolch, W. E.
2003-10-01
Two classes of anatomic models currently exist for use in both radiation protection and radiation dose reconstruction: stylized mathematical models and tomographic voxel models. The former utilize 3D surface equations to represent internal organ structure and external body shape, while the latter are based on segmented CT or MR images of a single individual. While tomographic models are clearly more anthropomorphic than stylized models, a given model's characterization as being anthropometric is dependent upon the reference human to which the model is compared. In the present study, data on total body mass, standing/sitting heights and body mass index are collected and reviewed for the US population covering the time interval from 1971 to 2000. These same anthropometric parameters are then assembled for the ORNL series of stylized models, the GSF series of tomographic models (Golem, Helga, Donna, etc), the adult male Zubal tomographic model and the UF newborn tomographic model. The stylized ORNL models of the adult male and female are found to be fairly representative of present-day average US males and females, respectively, in terms of both standing and sitting heights for ages between 20 and 60-80 years. While the ORNL adult male model provides a reasonably close match to the total body mass of the average US 21-year-old male (within ~5%), present-day 40-year-old males have an average total body mass that is ~16% higher. For radiation protection purposes, the use of the larger 73.7 kg adult ORNL stylized hermaphrodite model provides a much closer representation of average present-day US females at ages ranging from 20 to 70 years. In terms of the adult tomographic models from the GSF series, only Donna (40-year-old F) closely matches her age-matched US counterpart in terms of average body mass. Regarding standing heights, the better matches to US age-correlated averages belong to Irene (32-year-old F) for the females and Golem (38-year-old M) for the males. Both Helga (27-year-old F) and Donna, however, provide good matches to average US sitting heights for adult females, while Golem and Otoko (male of unknown age) yield sitting heights that are slightly below US adult male averages. Finally, Helga is seen as the only GSF tomographic female model that yields a body mass index in line with her average US female counterpart at age 26. In terms of dose reconstruction activities, however, all current tomographic voxel models are valuable assets in attempting to cover the broad distribution of individual anthropometric parameters representative of the current US population. It is highly recommended that similar attempts to create a broad library of tomographic models be initiated in the United States and elsewhere to complement and extend the limited number of tomographic models presently available for these efforts.
Noninvasive imaging analysis of biological tissue associated with laser thermal injury.
Chang, Cheng-Jen; Yu, De-Yi; Hsiao, Yen-Chang; Ho, Kuang-Hua
2017-04-01
The purpose of our study is to use a noninvasive tomographic imaging technique with high spatial resolution to characterize and monitor biological tissue responses associated with laser thermal injury. Optical doppler tomography (ODT) combines laser doppler flowmetry (LDF) with optical coherence tomography (OCT) to obtain high resolution tomographic velocity and structural images of static and moving constituents in highly scattering biological tissues. A SurgiLase XJ150 carbon dioxide (CO 2 ) laser using a continuous mode of 3 watts (W) was used to create first, second or third degree burns on anesthetized Sprague-Dawley rats. Additional parameters for laser thermal injury were assessed as well. The rationale for using ODT in the evaluation of laser thermal injury offers a means of constructing a high resolution tomographic image of the structure and perfusion of laser damaged skin. In the velocity images, the blood flow is coded at 1300 μm/s and 0 velocity, 1000 μm/s and 0 velocity, 700 μm/s and 0 velocity adjacent to the first, second, and third degree injuries, respectively. ODT produces exceptional spatial resolution while having a non-invasive way of measurement, therefore, ODT is an accurate measuring method for high-resolution fluid flow velocity and structural images for biological tissue with laser thermal injury. Copyright © 2017 Chang Gung University. Published by Elsevier B.V. All rights reserved.
Extreme ultraviolet and Soft X-ray diagnostic upgrade on the HBT-EP tokamak: Progress and Results
NASA Astrophysics Data System (ADS)
Desanto, S.; Levesque, J. P.; Battey, A.; Brooks, J. W.; Mauel, M. E.; Navratil, G. A.; Hansen, C. J.
2017-10-01
In order to understand internal MHD mode structure in a tokamak plasma, it is helpful to understand temperature and density fluctuations within that plasma. In the HBT-EP tokamak, the plasma emits bremsstrahlung radiation in the extreme ultraviolet (EUV) and soft x-ray (SXR) regimes, and the emitted power is primarily related to electron density and temperature. This radiation is detected by photodiode arrays located at several different angular positions near the plasma's edge, each array making several views through a poloidal slice of plasma. From these measurements a 2-d emissivity profile of that slice can be reconstructed with tomographic algorithms. This profile cannot directly tell us whether the emissivity is due to electron density, temperature, line emission, or charge recombination; however, when combined with information from other diagnostics, it can provide strong evidence of the type of internal mode or modes depending on the temporal-spatial context. We present ongoing progress and results on the installation of a new system that will eventually consist of four arrays of 16 views each and a separate two-color, 16-chord tangential system, which will provide an improved understanding of the internal structure of HBT-EP plasmas. Supported by U.S. DOE Grant DE-FG02-86ER5322.
Anthropomorphic thorax phantom for cardio-respiratory motion simulation in tomographic imaging
NASA Astrophysics Data System (ADS)
Bolwin, Konstantin; Czekalla, Björn; Frohwein, Lynn J.; Büther, Florian; Schäfers, Klaus P.
2018-02-01
Patient motion during medical imaging using techniques such as computed tomography (CT), magnetic resonance imaging (MRI), positron emission tomography (PET), or single emission computed tomography (SPECT) is well known to degrade images, leading to blurring effects or severe artifacts. Motion correction methods try to overcome these degrading effects. However, they need to be validated under realistic conditions. In this work, a sophisticated anthropomorphic thorax phantom is presented that combines several aspects of a simulator for cardio-respiratory motion. The phantom allows us to simulate various types of cardio-respiratory motions inside a human-like thorax, including features such as inflatable lungs, beating left ventricular myocardium, respiration-induced motion of the left ventricle, moving lung lesions, and moving coronary artery plaques. The phantom is constructed to be MR-compatible. This means that we can not only perform studies in PET, SPECT and CT, but also inside an MRI system. The technical features of the anthropomorphic thorax phantom Wilhelm are presented with regard to simulating motion effects in hybrid emission tomography and radiotherapy. This is supplemented by a study on the detectability of small coronary plaque lesions in PET/CT under the influence of cardio-respiratory motion, and a study on the accuracy of left ventricular blood volumes.
A comparison of newborn stylized and tomographic models for dose assessment in paediatric radiology
NASA Astrophysics Data System (ADS)
Staton, R. J.; Pazik, F. D.; Nipper, J. C.; Williams, J. L.; Bolch, W. E.
2003-04-01
Establishment of organ doses from diagnostic and interventional examinations is a key component to quantifying the radiation risks from medical exposures and for formulating corresponding dose-reduction strategies. Radiation transport models of human anatomy provide a convenient method for simulating radiological examinations. At present, two classes of models exist: stylized mathematical models and tomographic voxel models. In the present study, organ dose comparisons are made for projection radiographs of both a stylized and a tomographic model of the newborn patient. Sixteen separate radiographs were simulated for each model at x-ray technique factors typical of newborn examinations: chest, abdomen, thorax and head views in the AP, PA, left LAT and right LAT projection orientation. For AP and PA radiographs of the torso (chest, abdomen and thorax views), the effective dose assessed for the tomographic model exceeds that for the stylized model with per cent differences ranging from 19% (AP abdominal view) to 43% AP chest view. In contrast, the effective dose for the stylized model exceeds that for the tomographic model for all eight lateral views including those of the head, with per cent differences ranging from 9% (LLAT chest view) to 51% (RLAT thorax view). While organ positioning differences do exist between the models, a major factor contributing to differences in effective dose is the models' exterior trunk shape. In the tomographic model, a more elliptical shape is seen thus providing for less tissue shielding for internal organs in the AP and PA directions, with corresponding increased tissue shielding in the lateral directions. This observation is opposite of that seen in comparisons of stylized and tomographic models of the adult.
Montz, R; Perez-Castejón, M J; Jurado, J A; Martín-Comín, J; Esplugues, E; Salgado, L; Ventosa, A; Cantinho, G; Sá, E P; Fonseca, A T; Vieira, M R
1996-06-01
Technetium-99m tetrofosmin (Myoview) has unique properties for myocardial perfusion imaging very early after injection of the tracer. We used a very short same-day rest/stress protocol, to be performed within 2 h and evaluated its diagnostic accuracy. The study included 144 patients from seven Spanish and four Portuguese centres with a diagnosis of uncomplicated coronary artery disease (CAD); 78 patients (54%) had no history of prior myocardial infarction. Patients were injected with =300 MBq 99mTc-tetrofosmin at rest and =900 MBq approximately 1 h later at peak exercise. Single-photon emission tomographic (SPET) acquisitions were initiated within 5-30 min post injection. The results were compared with those of coronary angiography (CA). The data of 142 patients were completely evaluable (two with non-evaluable images were excluded). The quality of rest images was excellent or good in 86%, regionally problematic in 7%, poor but well interpretable in 5% and non-evaluable in 2%. The overall sensitivity for the detection of CAD was 93%, the specificity 38% and the accuracy 85%. The localization of defects by SPET in relation to the perfusion territories of stenosed vessels (>/=50%) was achieved with a sensitivity of 64% for the left anterior descending artery, 49% for the left circumflex artery and 86% for the right coronary artery, and an accuracy of 71%, 72% and 73% respectively. Concordance of SPET and CA was 62% for single-vessel disease and 68% for multivessel disease. In conclusion, this Spanish-Portuguese multicentre clinical trial confirmed, in a considerable number of patients who underwent coronary angiography, the feasibility of 99mTc tetrofosmin (Myoview) rest/stress myocardial SPET using a very short protocol (2 h).
NASA Astrophysics Data System (ADS)
Rahman, Tasneem; Tahtali, Murat; Pickering, Mark R.
2014-09-01
The purpose of this study is to derive optimized parameters for a detector module employing an off-the-shelf X-ray camera and a pinhole array collimator applicable for a range of different SPECT systems. Monte Carlo simulations using the Geant4 application for tomographic emission (GATE) were performed to estimate the performance of the pinhole array collimators and were compared to that of low energy high resolution (LEHR) parallel-hole collimator in a four head SPECT system. A detector module was simulated to have 48 mm by 48 mm active area along with 1mm, 1.6mm and 2 mm pinhole aperture sizes at 0.48 mm pitch on a tungsten plate. Perpendicular lead septa were employed to verify overlapping and non-overlapping projections against a proper acceptance angle without lead septa. A uniform shape cylindrical water phantom was used to evaluate the performance of the proposed four head SPECT system of the pinhole array detector module. For each head, 100 pinhole configurations were evaluated based on sensitivity and detection efficiency for 140 keV γ-rays, and compared to LEHR parallel-hole collimator. SPECT images were reconstructed based on filtered back projection (FBP) algorithm where neither scatter nor attenuation corrections were performed. A better reconstruction algorithm development for this specific system is in progress. Nevertheless, activity distribution was well visualized using the backprojection algorithm. In this study, we have evaluated several quantitative and comparative analyses for a pinhole array imaging system providing high detection efficiency and better system sensitivity over a large FOV, comparing to the conventional four head SPECT system. The proposed detector module is expected to provide improved performance in various SPECT imaging.
2017-07-31
Report: High-Energy, High-Pulse-Rate Light Sources for Enhanced Time -Resolved Tomographic PIV of Unsteady & Turbulent Flows The views, opinions and/or...reporting burden for this collection of information is estimated to average 1 hour per response, including the time for reviewing instructions, searching...High-Energy, High-Pulse-Rate Light Sources for Enhanced Time -Resolved Tomographic PIV of Unsteady & Turbulent Flows Report Term: 0-Other Email
Gupta, Rajiv; Jones, Stephen E; Mooyaart, Eline A Q; Pomerantz, Stuart R
2006-06-01
The development of multidetector row computed tomography (MDCT) now permits visualization of the entire vascular tree that is relevant for the management of stroke within 15 seconds. Advances in MDCT have brought computed tomography angiography (CTA) to the frontline in evaluation of stroke. CTA is a rapid and noninvasive modality for evaluating the neurovasculature. This article describes the role of CTA in the management of stroke. Fundamentals of contrast delivery, common pathologic findings, artifacts, and pitfalls in CTA interpretation are discussed.
Image processing pipeline for synchrotron-radiation-based tomographic microscopy.
Hintermüller, C; Marone, F; Isenegger, A; Stampanoni, M
2010-07-01
With synchrotron-radiation-based tomographic microscopy, three-dimensional structures down to the micrometer level can be visualized. Tomographic data sets typically consist of 1000 to 1500 projections of 1024 x 1024 to 2048 x 2048 pixels and are acquired in 5-15 min. A processing pipeline has been developed to handle this large amount of data efficiently and to reconstruct the tomographic volume within a few minutes after the end of a scan. Just a few seconds after the raw data have been acquired, a selection of reconstructed slices is accessible through a web interface for preview and to fine tune the reconstruction parameters. The same interface allows initiation and control of the reconstruction process on the computer cluster. By integrating all programs and tools, required for tomographic reconstruction into the pipeline, the necessary user interaction is reduced to a minimum. The modularity of the pipeline allows functionality for new scan protocols to be added, such as an extended field of view, or new physical signals such as phase-contrast or dark-field imaging etc.
Optimal joule heating of the subsurface
Berryman, James G.; Daily, William D.
1994-01-01
A method for simultaneously heating the subsurface and imaging the effects of the heating. This method combines the use of tomographic imaging (electrical resistance tomography or ERT) to image electrical resistivity distribution underground, with joule heating by electrical currents injected in the ground. A potential distribution is established on a series of buried electrodes resulting in energy deposition underground which is a function of the resistivity and injection current density. Measurement of the voltages and currents also permits a tomographic reconstruction of the resistivity distribution. Using this tomographic information, the current injection pattern on the driving electrodes can be adjusted to change the current density distribution and thus optimize the heating. As the heating changes conditions, the applied current pattern can be repeatedly adjusted (based on updated resistivity tomographs) to affect real time control of the heating.
GPS tomographic experiment on water vapour dynamics in the troposphere over Lisbon
NASA Astrophysics Data System (ADS)
Benevides, Pedro; Catalao, Joao; Miranda, Pedro
2015-04-01
Quantification of the water vapour variability on the atmosphere remains a difficult task, affecting the weather prediction. Coarse water vapour resolution measurements in space and time affect the numerical weather prediction solution models causing artifacts in the prediction of severe weather phenomena. The GNSS atmospheric processing has been developed in the past years providing integrated water vapour estimates comparable with the meteorological sensor measurements, with studies registering 1 to 2 kg/m2 bias, but lack a vertical determination of the atmospheric processes. The GNSS tomography in the troposphere is one of the most promising techniques for sensing the three-dimensional water vapour state of the atmosphere. The determination of the integrated water vapour profile by means of the widely accepted GNSS meteorology techniques, allows the reconstruction of several slant path delay rays in the satellite line of view, providing an opportunity to sense the troposphere at tree-dimensions plus time. The tomographic system can estimate an image solution of the water vapour but impositions have to be introduced to the system of equations inversion because of the non-optimal GNSS observation geometry. Application of this technique on atmospheric processes like large convective precipitation or mesoscale water vapour circulation have been able to describe its local dynamic vertical variation. A 3D tomographic experiment was developed over an area of 60x60 km2 around Lisbon (Portugal). The GNSS network available composed by 9 receivers was used for an experiment of densification of the permanent network using 8 temporarily installed GPS receivers (totalling 17 stations). This study was performed during several weeks in July 2013, where a radiosonde campaign was also held in order to validate the tomographic inversion solution. 2D integrated water vapour maps directly obtained from the GNSS processing were also evaluated and local coastal breeze circulation patterns were identified. Preliminary results show good agreement between radiosonde vertical profiles of water vapour and the correspondent grid columnar profile of the tomographic solution. This study aims for a preliminary characterization of the 3D water vapour field over this region, investigating its potential for monitor small scale air circulation on coastal areas like sea breeze meteorological phenomenon. This study was funded by the Portuguese Science Foundation FCT, under project SMOG PTDC/CTE-ATM/119922/2010 and PhD grant SFRH/BD/80288/2011.
Gaina, Carmen; Medvedev, Sergei; Torsvik, Trond H; Koulakov, Ivan; Werner, Stephanie C
Knowledge about the Arctic tectonic structure has changed in the last decade as a large number of new datasets have been collected and systematized. Here, we review the most updated, publicly available Circum-Arctic digital compilations of magnetic and gravity data together with new models of the Arctic's crust. Available tomographic models have also been scrutinized and evaluated for their potential to reveal the deeper structure of the Arctic region. Although the age and opening mechanisms of the Amerasia Basin are still difficult to establish in detail, interpreted subducted slabs that reside in the High Arctic's lower mantle point to one or two episodes of subduction that consumed crust of possibly Late Cretaceous-Jurassic age. The origin of major igneous activity during the Cretaceous in the central Arctic (the Alpha-Mendeleev Ridge) and in the proximity of rifted margins (the so-called High Arctic Large Igneous Province-HALIP) is still debated. Models of global plate circuits and the connection with the deep mantle are used here to re-evaluate a possible link between Arctic volcanism and mantle plumes.
Pathan, Faraz; Hecht, Harvey; Narula, Jagat; Marwick, Thomas H
2018-04-01
Evaluation of the left atrium and left atrial appendage for the presence of thrombus prior to cardioversion and pulmonary vein isolation, and of the entire heart for embolic sources in the setting of cryptogenic stroke, has long been standard medical care. Guidelines have uniformly recommended transesophageal echocardiography (TEE) to accomplish these goals. In recent years, computed tomographic angiography has demonstrated diagnostic accuracy similar to that of TEE for the detection of thrombus. Analysis of the pertinent data and relative merits of the 2 technologies leads to the conclusions that: 1) both modalities have some unique, nonoverlapping capabilities that may dictate their use in specific situations; 2) computed tomographic angiography is a reasonable alternative to TEE when the primary aim is to exclude left atrial and left atrial appendage thrombus and in patients in whom the risks associated with TEE outweigh the benefits; and 3) both options should be discussed with the patient in the setting of shared decision making. Copyright © 2018 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Conjugate-gradient preconditioning methods for shift-variant PET image reconstruction.
Fessler, J A; Booth, S D
1999-01-01
Gradient-based iterative methods often converge slowly for tomographic image reconstruction and image restoration problems, but can be accelerated by suitable preconditioners. Diagonal preconditioners offer some improvement in convergence rate, but do not incorporate the structure of the Hessian matrices in imaging problems. Circulant preconditioners can provide remarkable acceleration for inverse problems that are approximately shift-invariant, i.e., for those with approximately block-Toeplitz or block-circulant Hessians. However, in applications with nonuniform noise variance, such as arises from Poisson statistics in emission tomography and in quantum-limited optical imaging, the Hessian of the weighted least-squares objective function is quite shift-variant, and circulant preconditioners perform poorly. Additional shift-variance is caused by edge-preserving regularization methods based on nonquadratic penalty functions. This paper describes new preconditioners that approximate more accurately the Hessian matrices of shift-variant imaging problems. Compared to diagonal or circulant preconditioning, the new preconditioners lead to significantly faster convergence rates for the unconstrained conjugate-gradient (CG) iteration. We also propose a new efficient method for the line-search step required by CG methods. Applications to positron emission tomography (PET) illustrate the method.
NASA Astrophysics Data System (ADS)
Bai, Bing
2012-03-01
There has been a lot of work on total variation (TV) regularized tomographic image reconstruction recently. Many of them use gradient-based optimization algorithms with a differentiable approximation of the TV functional. In this paper we apply TV regularization in Positron Emission Tomography (PET) image reconstruction. We reconstruct the PET image in a Bayesian framework, using Poisson noise model and TV prior functional. The original optimization problem is transformed to an equivalent problem with inequality constraints by adding auxiliary variables. Then we use an interior point method with logarithmic barrier functions to solve the constrained optimization problem. In this method, a series of points approaching the solution from inside the feasible region are found by solving a sequence of subproblems characterized by an increasing positive parameter. We use preconditioned conjugate gradient (PCG) algorithm to solve the subproblems directly. The nonnegativity constraint is enforced by bend line search. The exact expression of the TV functional is used in our calculations. Simulation results show that the algorithm converges fast and the convergence is insensitive to the values of the regularization and reconstruction parameters.
Kubo, N
1995-04-01
To improve the quality of single-photon emission computed tomographic (SPECT) images, a restoration filter has been developed. This filter was designed according to practical "least squares filter" theory. It is necessary to know the object power spectrum and the noise power spectrum. The power spectrum is estimated from the power spectrum of a projection, when the high-frequency power spectrum of a projection is adequately approximated as a polynomial exponential expression. A study of the restoration with the filter based on a projection power spectrum was conducted, and compared with that of the "Butterworth" filtering method (cut-off frequency of 0.15 cycles/pixel), and "Wiener" filtering (signal-to-noise power spectrum ratio was a constant). Normalized mean-squared errors (NMSE) of the phantom, two line sources located in a 99mTc filled cylinder, were used. NMSE of the "Butterworth" filter, "Wiener" filter, and filtering based on a power spectrum were 0.77, 0.83, and 0.76 respectively. Clinically, brain SPECT images utilizing this new restoration filter improved the contrast. Thus, this filter may be useful in diagnosis of SPECT images.
Tomographic imaging of subducted lithosphere below northwest Pacific island arcs
Van Der Hilst, R.; Engdahl, R.; Spakman, W.; Nolet, G.
1991-01-01
The seismic tomography problem does not have a unique solution, and published tomographic images have been equivocal with regard to the deep structure of subducting slabs. An improved tomographic method, using a more realistic background Earth model and surf ace-reflected as well as direct seismic phases, shows that slabs beneath the Japan and Izu Bonin island arcs are deflected at the boundary between upper and lower mantle, whereas those beneath the northern Kuril and Mariana arcs sink into the lower mantle.
Business aspects of cardiovascular computed tomography: tackling the challenges.
Bateman, Timothy M
2008-01-01
The purpose of this article is to provide a comprehensive understanding of the business issues surrounding provision of dedicated cardiovascular computed tomographic imaging. Some of the challenges include high up-front costs, current low utilization relative to scanner capability, and inadequate payments. Cardiovascular computed tomographic imaging is a valuable clinical modality that should be offered by cardiovascular centers-of-excellence. With careful consideration of the business aspects, moderate-to-large size cardiology programs should be able to implement an economically viable cardiovascular computed tomographic service.
NASA Astrophysics Data System (ADS)
Karagiannis, Georgios
2017-03-01
This work led to a new method named 3D spectracoustic tomographic mapping imaging. The current and the future work is related to the fabrication of a combined acoustic microscopy transducer and infrared illumination probe permitting the simultaneous acquisition of the spectroscopic and the tomographic information. This probe provides with the capability of high fidelity and precision registered information from the combined modalities named spectracoustic information.
2016-04-28
Single- shot , volumetrically illuminated, three- dimensional, tomographic laser-induced- fluorescence imaging in a gaseous free jet Benjamin R. Halls...us.af.mil Abstract: Single- shot , tomographic imaging of the three-dimensional concentration field is demonstrated in a turbulent gaseous free jet in co-flow...2001). 6. K. M. Tacina and W. J. A. Dahm, “Effects of heat release on turbulent shear flows, Part 1. A general equivalence principle for non-buoyant
Zhang, T; Godavarthi, C; Chaumet, P C; Maire, G; Giovannini, H; Talneau, A; Prada, C; Sentenac, A; Belkebir, K
2015-02-15
Tomographic diffractive microscopy is a marker-free optical digital imaging technique in which three-dimensional samples are reconstructed from a set of holograms recorded under different angles of incidence. We show experimentally that, by processing the holograms with singular value decomposition, it is possible to image objects in a noisy background that are invisible with classical wide-field microscopy and conventional tomographic reconstruction procedure. The targets can be further characterized with a selective quantitative inversion.
Limited-angle tomography for analyzer-based phase-contrast X-ray imaging
Majidi, Keivan; Wernick, Miles N; Li, Jun; Muehleman, Carol; Brankov, Jovan G
2014-01-01
Multiple-Image Radiography (MIR) is an analyzer-based phase-contrast X-ray imaging method (ABI), which is emerging as a potential alternative to conventional radiography. MIR simultaneously generates three planar parametric images containing information about scattering, refraction and attenuation properties of the object. The MIR planar images are linear tomographic projections of the corresponding object properties, which allows reconstruction of volumetric images using computed tomography (CT) methods. However, when acquiring a full range of linear projections around the tissue of interest is not feasible or the scanning time is limited, limited-angle tomography techniques can be used to reconstruct these volumetric images near the central plane, which is the plane that contains the pivot point of the tomographic movement. In this work, we use computer simulations to explore the applicability of limited-angle tomography to MIR. We also investigate the accuracy of reconstructions as a function of number of tomographic angles for a fixed total radiation exposure. We use this function to find an optimal range of angles over which data should be acquired for limited-angle tomography MIR (LAT-MIR). Next, we apply the LAT-MIR technique to experimentally acquired MIR projections obtained in a cadaveric human thumb study. We compare the reconstructed slices near the central plane to the same slices reconstructed by CT-MIR using the full angular view around the object. Finally, we perform a task-based evaluation of LAT-MIR performance for different numbers of angular views, and use template matching to detect cartilage in the refraction image near the central plane. We use the signal-to-noise ratio of this test as the detectability metric to investigate an optimum range of tomographic angles for detecting soft tissues in LAT-MIR. Both results show that there is an optimum range of angular view for data acquisition where LAT-MIR yields the best performance, comparable to CT-MIR only if one considers volumetric images near the central plane and not the whole volume. PMID:24898008
Limited-angle tomography for analyzer-based phase-contrast x-ray imaging
NASA Astrophysics Data System (ADS)
Majidi, Keivan; Wernick, Miles N.; Li, Jun; Muehleman, Carol; Brankov, Jovan G.
2014-07-01
Multiple-image radiography (MIR) is an analyzer-based phase-contrast x-ray imaging method, which is emerging as a potential alternative to conventional radiography. MIR simultaneously generates three planar parametric images containing information about scattering, refraction and attenuation properties of the object. The MIR planar images are linear tomographic projections of the corresponding object properties, which allows reconstruction of volumetric images using computed tomography (CT) methods. However, when acquiring a full range of linear projections around the tissue of interest is not feasible or the scanning time is limited, limited-angle tomography techniques can be used to reconstruct these volumetric images near the central plane, which is the plane that contains the pivot point of the tomographic movement. In this work, we use computer simulations to explore the applicability of limited-angle tomography to MIR. We also investigate the accuracy of reconstructions as a function of number of tomographic angles for a fixed total radiation exposure. We use this function to find an optimal range of angles over which data should be acquired for limited-angle tomography MIR (LAT-MIR). Next, we apply the LAT-MIR technique to experimentally acquired MIR projections obtained in a cadaveric human thumb study. We compare the reconstructed slices near the central plane to the same slices reconstructed by CT-MIR using the full angular view around the object. Finally, we perform a task-based evaluation of LAT-MIR performance for different numbers of angular views, and use template matching to detect cartilage in the refraction image near the central plane. We use the signal-to-noise ratio of this test as the detectability metric to investigate an optimum range of tomographic angles for detecting soft tissues in LAT-MIR. Both results show that there is an optimum range of angular view for data acquisition where LAT-MIR yields the best performance, comparable to CT-MIR only if one considers volumetric images near the central plane and not the whole volume.
Punwani, Shonit; Taylor, Stuart A; Bainbridge, Alan; Prakash, Vineet; Bandula, Steven; De Vita, Enrico; Olsen, Oystein E; Hain, Sharon F; Stevens, Nicola; Daw, Stephen; Shankar, Ananth; Bomanji, Jamshed B; Humphries, Paul D
2010-04-01
To compare the diagnostic performance of rapid whole-body anatomic magnetic resonance (MR) staging of pediatric and adolescent lymphoma to an enhanced positron emission tomographic (PET)/computed tomographic (CT) reference standard. Ethical permission was given by the University College London Hospital ethics committee, and informed written consent was obtained from all participants and/or parents or guardians. Thirty-one subjects (age range, 7.3-18.0 years; 18 male, 11 female) with histologically proved lymphoma were prospectively recruited. Pretreatment staging was performed with whole-body short inversion time inversion-recovery (STIR) half-Fourier rapid acquisition with relaxation enhancement (RARE) MR imaging, fluorine 18 fluorodeoxyglucose PET/CT, and contrast agent-enhanced chest CT. Twenty-six subjects had posttreatment PET/CT and compromised our final cohort. Eleven nodal and 11 extranodal sites per patient were assessed on MR imaging by two radiologists in consensus, with a nodal short-axis threshold of >1 cm and predefined extranodal positivity criteria. The same sites were independantly evaluated by two nuclear medicine physicians on PET/CT images. Disease positivity was defined as a maximum standardized uptake value >2.5 or nodal size >1 cm. An unblinded expert panel reevaluated the imaging findings, removing perceptual errors, and derived an enhanced PET/CT reference standard (taking into account chest CT and 3-month follow-up imaging) against which the reported and intrinsic performance of MR imaging was assessed by using the kappa statistic. There was very good agreement between MR imaging and the enhanced PET/CT reference standard for nodal and extranodal staging (kappa = 0.96 and 0.86, respectively) which improved following elimination of perceptual errors (kappa = 0.97 and 0.91, respectively). The sensitivity and specificity of MR imaging (following removal of perceptual error) were 98% and 99%, respectively, for nodal disease and 91% and 99%, respectively, for extranodal disease. Whole-body STIR half-Fourier RARE MR imaging of pediatric and adolescent lymphoma can accurately depict nodal and extranodal disease and may provide an alternative nonionizing imaging method for anatomic disease assessment at initial staging. RSNA, 2010
Elmaleh, D. R.; Fischman, A. J.; Tawakol, A.; Zhu, A.; Shoup, T. M.; Hoffmann, U.; Brownell, A.-L.; Zamecnik, P. C.
2006-01-01
Diadenosine-5′,5‴-P1,P4-tetraphosphate (Ap4A) and its analog P2,P3-monochloromethylene diadenosine-5′,5‴-P1,P4-tetraphosphate (AppCHClppA) are competitive inhibitors of adenosine diphosphate-induced platelet aggregation, which plays a central role in arterial thrombosis and plaque formation. In this study, we evaluate the imaging capabilities of positron-emission tomography (PET) with P2,P3-[18F]monofluoromethylene diadenosine-5′,5‴-P1,P4-tetraphosphate ([18F]AppCHFppA) to detect atherosclerotic lesions in male New Zealand White rabbits. Three to six months after balloon injury to the aorta, the rabbits were injected with [18F]AppCHFppA, and microPET imaging showed rapid accumulation of this radiopharmaceutical in the atherosclerotic abdominal aorta, with lesions clearly visible 30 min after injection. Computed tomographic images were coregistered with PET images to improve delineation of aortoiliac tracer activity. Plaque macrophage density, quantified by immunostaining with RAM11 against rabbit macrophages, correlated with PET measurements of [18F]AppCHFppA uptake (r = 0.87, P < 0.0001), whereas smooth-muscle cell density, quantified by immunostaining with 1A4 against smooth muscle actin, did not. Biodistribution studies of [18F]AppCHFppA in normal rats indicated typical adenosine dinucleotide behavior with insignificant myocardial uptake and fast kidney clearance. The accumulation of [18F]AppCHFppA in macrophage-rich atherosclerotic plaques can be quantified noninvasively with PET. Hence, [18F]AppCHFppA holds promise for the noninvasive characterization of vascular inflammation. PMID:17038498
Paine, Nicola J; Bacon, Simon L; Pelletier, Roxanne; Arsenault, André; Diodati, Jean G; Lavoie, Kim L
2016-02-01
Women diagnosed with coronary artery disease (CAD) typically experience worse outcomes relative to men, possibly through diagnosis and treatment delays. Reasons for these delays may be influenced by mood and anxiety disorders, which are more prevalent in women and have symptoms (eg, palpitations and fatigue) that may be confounded with CAD. Our study examined sex differences in the association between mood and anxiety disorders and myocardial ischemia in patients with and without a CAD history presenting for exercise stress tests. A total of 2342 patients (women n=760) completed a single photon emission computed tomographic exercise stress test (standard Bruce Protocol) and underwent a psychiatric interview (The Primary Care Evaluation of Mental Disorders) to assess mood and anxiety disorders. Ischemia was assessed using single photon emission computed tomography, with odds ratio used to calculate the effect of sex and mood/anxiety on the presence of ischemia during stress testing by CAD history in a stratified analyses, adjusted for relevant covariates. There was a sex by anxiety interaction with ischemia in those without a CAD history (P=0.015): women with anxiety were more likely to exhibit ischemia during exercise than women without anxiety (odds ratio, 1.75; 95% confidence interval, 1.05-2.89). No significant effects were observed for men nor mood. Women with anxiety and no CAD history had higher rates of ischemia than women without anxiety. Results suggest that anxiety symptoms, many of which overlap with those of CAD, might mask CAD symptoms among women (but not men) and contribute to referral and diagnostic delays. Further research is needed to confirm this hypothesis. © 2016 American Heart Association, Inc.
Optimal joule heating of the subsurface
Berryman, J.G.; Daily, W.D.
1994-07-05
A method for simultaneously heating the subsurface and imaging the effects of the heating is disclosed. This method combines the use of tomographic imaging (electrical resistance tomography or ERT) to image electrical resistivity distribution underground, with joule heating by electrical currents injected in the ground. A potential distribution is established on a series of buried electrodes resulting in energy deposition underground which is a function of the resistivity and injection current density. Measurement of the voltages and currents also permits a tomographic reconstruction of the resistivity distribution. Using this tomographic information, the current injection pattern on the driving electrodes can be adjusted to change the current density distribution and thus optimize the heating. As the heating changes conditions, the applied current pattern can be repeatedly adjusted (based on updated resistivity tomographs) to affect real time control of the heating.
Wang, Dengjiang; Zhang, Weifang; Wang, Xiangyu; Sun, Bo
2016-01-01
This study presents a novel monitoring method for hole-edge corrosion damage in plate structures based on Lamb wave tomographic imaging techniques. An experimental procedure with a cross-hole layout using 16 piezoelectric transducers (PZTs) was designed. The A0 mode of the Lamb wave was selected, which is sensitive to thickness-loss damage. The iterative algebraic reconstruction technique (ART) method was used to locate and quantify the corrosion damage at the edge of the hole. Hydrofluoric acid with a concentration of 20% was used to corrode the specimen artificially. To estimate the effectiveness of the proposed method, the real corrosion damage was compared with the predicted corrosion damage based on the tomographic method. The results show that the Lamb-wave-based tomographic method can be used to monitor the hole-edge corrosion damage accurately. PMID:28774041
Transmyocardial revascularization on canine with Ho:YAG laser - an experimental study
NASA Astrophysics Data System (ADS)
Bao, Xiaoqing; Zhu, Jing; Zhang, Hui-Guo
2005-07-01
Background and Objective: To evaluate the efficiency of transmyocardial revascularization with Ho:YAG laser and find out adequate physical parameters of the laser. Materials and Methods: 10 dogs were studied. All the samples were divided into two groups: the laser group (5 dogs) and the control group (5 dogs). Acute myocardial ischemia was induced in all the samples, and transmyocardial laser revascularization (TMLR) was only done in the laser group. We compared the difference of improvement in myocardial perfusion between the two groups with single photon emission computed tomograph (SPECT) and observed the patency of the laser channels and heat injures in the tissue adjacent to the channels with light- and electro-scope. Results: After 4 weeks, the recovery of myocardial perfusion was significantly faster in the laser group than in the control group through SPECT (P<0.05). Most of the laser channels drilled with Ho:YAG laser were filled with fibrin. There were amount of microvessels and erythrocytes inside and around the channels. Only slight heat injures were seen in the tissue adjacent to the channels. Only 20-30 watts were needed in TMLR. Conclusions: Transmyocardial revascularization with Ho:YAG laser limits infarct expansion and reduces myocardial ischemia efficiently. TMLR with Ho:YAG laser can become a new technique to treat ischemic heart disease.
NASA Astrophysics Data System (ADS)
Faber, Tracy L.; Garcia, Ernest V.; Lalush, David S.; Segars, W. Paul; Tsui, Benjamin M.
2001-05-01
The spline-based Mathematical Cardiac Torso (MCAT) phantom is a realistic software simulation designed to simulate single photon emission computed tomographic (SPECT) data. It incorporates a heart model of known size and shape; thus, it is invaluable for measuring accuracy of acquisition, reconstruction, and post-processing routines. New functionality has been added by replacing the standard heart model with left ventricular (LV) epicaridal and endocardial surface points detected from actual patient SPECT perfusion studies. LV surfaces detected from standard post-processing quantitation programs are converted through interpolation in space and time into new B-spline models. Perfusion abnormalities are added to the model based on results of standard perfusion quantification. The new LV is translated and rotated to fit within existing atria and right ventricular models, which are scaled based on the size of the LV. Simulations were created for five different patients with myocardial infractions who had undergone SPECT perfusion imaging. Shape, size, and motion of the resulting activity map were compared visually to the original SPECT images. In all cases, size, shape and motion of simulated LVs matched well with the original images. Thus, realistic simulations with known physiologic and functional parameters can be created for evaluating efficacy of processing algorithms.
CO 2 Mineral Sequestration in Naturally Porous Basalt
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xiong, Wei; Wells, Rachel K.; Horner, Jake A.
2018-02-27
Continental flood basalts are extensive geologic features currently being evaluated as reservoirs that are suitable for long-term storage of carbon emissions. Favorable attributes of these formations for containment of injected carbon dioxide (CO2) include high mineral trapping capacity, unique structural features, and enormous volumes. We experimentally investigated mineral carbonation in whole core samples retrieved from the Grand Ronde basalt, the same formation into which ~1000 t of CO2 was recently injected in an eastern Washington pilot-scale demonstration. The rate and extent of carbonate mineral formation at 100 °C and 100 bar were tracked via time-resolved sampling of bench-scale experiments. Basaltmore » cores were recovered from the reactor after 6, 20, and 40 weeks, and three-dimensional X-ray tomographic imaging of these cores detected carbonate mineral formation in the fracture network within 20 weeks. Under these conditions, a carbon mineral trapping rate of 1.24 ± 0.52 kg of CO2/m3 of basalt per year was estimated, which is orders of magnitude faster than rates for deep sandstone reservoirs. On the basis of these calculations and under certain assumptions, available pore space within the Grand Ronde basalt formation would completely carbonate in ~40 years, resulting in solid mineral trapping of ~47 kg of CO2/m3 of basalt.« less
Yamakami, Shoji; Toyama, Junji; Okamoto, Mitsuhiro; Matsushita, Toyoaki; Murakami, Yoshimasa; Ogata, Masaki; Ito, Shigenori; Fukutomi, Tatsuya; Okayama, Naotsuka; Itoh, Makoto
2003-11-01
This study evaluates the usefullness of intravenous electron beam computed tomographic angiography (EBA) for the detection of coronary artery bypass graft patency in 43 patients (33 men and 10 women, mean age, 65 years) who had coronary artery bypass graft surgery. EBA was performed a few days before selective bypass graft angiography (SGA). Forty axial cross-sections of angiographic images of the heart were acquired consecutively by an electrocardiographic trigger signal at 40% of the RR interval, which corresponds to the end-systolic phase. EBA data were reconstructed as a three-dimensional shaded surface display of the heart and bypass grafts. Detectability of the patency of bypass gratis was evaluated, taking selective angiographic images of the bypass grafts as a gold standard. One hundred and nine grafts (96%) out of 114 grafts were subjected to evaluation: 37 grafts were left internal mammary artery grafts (LIMA), 7 were right internal mammary artery grafts (RIMA), 6 were gastroepiploic artery grafts (GEA), 7 were free gastroepiploic artery grafts with venous drainage (free-GEA), 7 were radial artery grafts (RAG), and 45 were saphenous vein gratis (SVG). The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of EBA were 98%, 100%, 100%, 91%, and 98%, respectively. EBA sampled at the end-systolic period was determined to be useful for the detection of coronary artery bypass graft patency and occlusion.
Rojas-Serrano, Jorge; Herrera-Bringas, Denisse; Pérez-Román, Diana I; Pérez-Dorame, Renzo; Mateos-Toledo, Heidegger; Mejía, Mayra
2017-07-01
Interstitial lung disease (ILD) is a severe rheumatoid arthritis (RA) manifestation. The worst survival has been associated with usual interstitial pneumonia (UIP) definitive pattern in high-resolution chest tomography (HRCT) scans. Moreover, the use of methotrexate in RA-ILD is controversial. Our aim was to evaluate prognostic factors including methotrexate in an RA-ILD cohort and their association with survival. RA-ILD patients referred for medical evaluation and treatment at a single center were included. At the baseline, pulmonary function tests were carried out and a HRCT was obtained. A radiologist evaluated the ILD tomographic pattern and the extent of lung disease. Patients were considered as receiving methotrexate therapy if this drug was specifically prescribed for the treatment of RA-ILD at the beginning of follow up. Seventy-eight patients were included. UIP definite pattern in HRCT was not associated to worse survival. Variables associated with mortality reflected the severity of lung disease. Treatment with methotrexate was associated with survival (HR 0.13, 95% CI 0.02-0.64); older patients had worse prognosis (HR 1.04, 95% CI 1.003-1.09). After adjusting for confounding variables, methotrexate was strongly associated with survival. Methotrexate treatment during follow up was associated with survival. The severity of lung disease and not the tomographic pattern is associated with mortality; older patients had worse prognosis.
Atwood, Robert C.; Bodey, Andrew J.; Price, Stephen W. T.; Basham, Mark; Drakopoulos, Michael
2015-01-01
Tomographic datasets collected at synchrotrons are becoming very large and complex, and, therefore, need to be managed efficiently. Raw images may have high pixel counts, and each pixel can be multidimensional and associated with additional data such as those derived from spectroscopy. In time-resolved studies, hundreds of tomographic datasets can be collected in sequence, yielding terabytes of data. Users of tomographic beamlines are drawn from various scientific disciplines, and many are keen to use tomographic reconstruction software that does not require a deep understanding of reconstruction principles. We have developed Savu, a reconstruction pipeline that enables users to rapidly reconstruct data to consistently create high-quality results. Savu is designed to work in an ‘orthogonal’ fashion, meaning that data can be converted between projection and sinogram space throughout the processing workflow as required. The Savu pipeline is modular and allows processing strategies to be optimized for users' purposes. In addition to the reconstruction algorithms themselves, it can include modules for identification of experimental problems, artefact correction, general image processing and data quality assessment. Savu is open source, open licensed and ‘facility-independent’: it can run on standard cluster infrastructure at any institution. PMID:25939626
Realistic prediction of individual facial emotion expressions for craniofacial surgery simulations
NASA Astrophysics Data System (ADS)
Gladilin, Evgeny; Zachow, Stefan; Deuflhard, Peter; Hege, Hans-Christian
2003-05-01
In addition to the static soft tissue prediction, the estimation of individual facial emotion expressions is an important criterion for the evaluation of the carniofacial surgery planning. In this paper, we present an approach for the estimation of individual facial emotion expressions on the basis of geometrical models of human anatomy derived from tomographic data and the finite element modeling of facial tissue biomechanics.
NASA Astrophysics Data System (ADS)
McGarry, Meghan B.
An innovative new soft x-ray (SXR) diagnostic has been developed for the Madison Symmetric Torus that provides measurements of tomographic emissivity and electron temperature (Te) via the double-foil technique. Two measurements of electron temperature from SXR emission are available, one from the ratio of the emissivities through thin and thick filters as mapped onto magnetic flux surfaces, and the other directly from the ratio of two foils sharing a single line-of-sight. The SXR measurements have been benchmarked against Thomson Scattering electron temperature during high current, improved confinement discharges, and show excellent agreement. The SXR diagnostic has been used to investigate the source of emissive structures seen during high-current improved confinement discharges. Although the emissivity structures are correlated to the magnetic configuration of the discharges, direct-brightness Te measurements do not typically show a clear Te structure, indicating a general upper limit of ˜ 15--20% on any possible localized increase in Te. In most shots, the flux-surface reconstructed Te shows no indication of Te structure. However, in one discharge with a very large tearing mode amplitude (15 Gauss), measurements and modeling indicate that the structure has a localized increase of 20-180 eV in Te. The structure cannot be explained by a localized enhancement of electron density. A second case study with a multiple-helicity magnetic spectrum indicates that a ring of enhanced SXR emission at 0.4 normalized radius is caused by an impurity accumulation of up to 58% that of the core region. For the first time, the SXR diagnostic has also been combined with Al11+ impurity measurements to normalize the aluminum contribution to the SXR emission spectrum and demonstrate that the filter thicknesses used for the diagnostic do not pass aluminum line radiation. The new SXR Te and tomography diagnostic will continue to provide insight into the relationship between magnetic structures and electron temperature in improved confinement plasmas.
NASA Astrophysics Data System (ADS)
Petit, C.; Le Louarn, M.; Fusco, T.; Madec, P.-Y.
2011-09-01
Various tomographic control solutions have been proposed during the last decades to ensure efficient or even optimal closed-loop correction to tomographic Adaptive Optics (AO) concepts such as Laser Tomographic AO (LTAO), Multi-Conjugate AO (MCAO). The optimal solution, based on Linear Quadratic Gaussian (LQG) approach, as well as suboptimal but efficient solutions such as Pseudo-Open Loop Control (POLC) require multiple Matrix Vector Multiplications (MVM). Disregarding their respective performance, these efficient control solutions thus exhibit strong increase of on-line complexity and their implementation may become difficult in demanding cases. Among them, two cases are of particular interest. First, the system Real-Time Computer architecture and implementation is derived from past or present solutions and does not support multiple MVM. This is the case of the AO Facility which RTC architecture is derived from the SPARTA platform and inherits its simple MVM architecture, which does not fit with LTAO control solutions for instance. Second, considering future systems such as Extremely Large Telescopes, the number of degrees of freedom is twenty to one hundred times bigger than present systems. In these conditions, tomographic control solutions can hardly be used in their standard form and optimized implementation shall be considered. Single MVM tomographic control solutions represent a potential solution, and straightforward solutions such as Virtual Deformable Mirrors have been already proposed for LTAO but with tuning issues. We investigate in this paper the possibility to derive from tomographic control solutions, such as POLC or LQG, simplified control solutions ensuring simple MVM architecture and that could be thus implemented on nowadays systems or future complex systems. We theoretically derive various solutions and analyze their respective performance on various systems thanks to numerical simulation. We discuss the optimization of their performance and stability issues with respect to classic control solutions. We finally discuss off-line computation and implementation constraints.
On the V-Line Radon Transform and Its Imaging Applications
Morvidone, M.; Nguyen, M. K.; Truong, T. T.; Zaidi, H.
2010-01-01
Radon transforms defined on smooth curves are well known and extensively studied in the literature. In this paper, we consider a Radon transform defined on a discontinuous curve formed by a pair of half-lines forming the vertical letter V. If the classical two-dimensional Radon transform has served as a work horse for tomographic transmission and/or emission imaging, we show that this V-line Radon transform is the backbone of scattered radiation imaging in two dimensions. We establish its analytic inverse formula as well as a corresponding filtered back projection reconstruction procedure. These theoretical results allow the reconstruction of two-dimensional images from Compton scattered radiation collected on a one-dimensional collimated camera. We illustrate the working principles of this imaging modality by presenting numerical simulation results. PMID:20706545
F-18 fluorodeoxyglucose: Its potential in differentiating between stress fracture and neoplasia
DOE Office of Scientific and Technical Information (OSTI.GOV)
Paul, R.; Ahonen, A.; Virtama, P.
1989-12-01
F-18 fluorodeoxyglucose (FDG) accumulates into regions of enhanced glucose uptake and metabolism such as the brain, heart, and malignant tumors. The clinical usefulness of this positron-emitting radiopharmaceutical is illustrated in a case where the clinical picture and CT indicated a malignant bone lesion in the clavicle. Histologically a stress fracture was found secondary to chronic strain on the clavicle. On follow-up the lesion's course was benign. Planar imaging with F-18 FDG was performed twice during follow-up, and on both occasions there was no accumulation of radioactivity over the suspicious area, indicating normal glucose consumption. This case demonstrates the differential diagnosticmore » potential of F-18 FDG and shows that clinically useful information may be obtained without a position emission tomograph.« less
Hill, K W; Bitter, M L; Scott, S D; Ince-Cushman, A; Reinke, M; Rice, J E; Beiersdorfer, P; Gu, M-F; Lee, S G; Broennimann, Ch; Eikenberry, E F
2008-10-01
A new spatially resolving x-ray crystal spectrometer capable of measuring continuous spatial profiles of high resolution spectra (lambda/d lambda>6000) of He-like and H-like Ar K alpha lines with good spatial (approximately 1 cm) and temporal (approximately 10 ms) resolutions has been installed on the Alcator C-Mod tokamak. Two spherically bent crystals image the spectra onto four two-dimensional Pilatus II pixel detectors. Tomographic inversion enables inference of local line emissivity, ion temperature (T(i)), and toroidal plasma rotation velocity (upsilon(phi)) from the line Doppler widths and shifts. The data analysis techniques, T(i) and upsilon(phi) profiles, analysis of fusion-neutron background, and predictions of performance on other tokamaks, including ITER, will be presented.
Assessing the resolution-dependent utility of tomograms for geostatistics
Day-Lewis, F. D.; Lane, J.W.
2004-01-01
Geophysical tomograms are used increasingly as auxiliary data for geostatistical modeling of aquifer and reservoir properties. The correlation between tomographic estimates and hydrogeologic properties is commonly based on laboratory measurements, co-located measurements at boreholes, or petrophysical models. The inferred correlation is assumed uniform throughout the interwell region; however, tomographic resolution varies spatially due to acquisition geometry, regularization, data error, and the physics underlying the geophysical measurements. Blurring and inversion artifacts are expected in regions traversed by few or only low-angle raypaths. In the context of radar traveltime tomography, we derive analytical models for (1) the variance of tomographic estimates, (2) the spatially variable correlation with a hydrologic parameter of interest, and (3) the spatial covariance of tomographic estimates. Synthetic examples demonstrate that tomograms of qualitative value may have limited utility for geostatistics; moreover, the imprint of regularization may preclude inference of meaningful spatial statistics from tomograms.
Computed Tomography Angiography in Microsurgery: Indications, Clinical Utility, and Pitfalls
Lee, Gordon K.; Fox, Paige M.; Riboh, Jonathan; Hsu, Charles; Saber, Sepideh; Rubin, Geoffrey D.; Chang, James
2013-01-01
Objective: Computed tomographic angiography (CTA) can be used to obtain 3-dimensional vascular images and soft-tissue definition. The goal of this study was to evaluate the reliability, usefulness, and pitfalls of CTA in preoperative planning of microvascular reconstructive surgery. Methods: A retrospective review of patients who obtained preoperative CTA in preparation for planned microvascular reconstruction was performed over a 5-year period (2001–2005). The influence of CTA on the original operative plan was assessed for each patient, and CTA results were correlated to the operative findings. Results: Computed tomographic angiography was performed on 94 patients in preparation for microvascular reconstruction. In 48 patients (51%), vascular abnormalities were noted on CTA. Intraoperative findings correlated with CTA results in 97% of cases. In 42 patients (45%), abnormal CTA findings influenced the original operative plan, such as the choice of vessels, side of harvest, or nature of the reconstruction (local flap instead of free tissue transfer). Technical difficulties in performing CTA were encountered in 5 patients (5%) in whom interference from external fixation devices was the main cause. Conclusions: This large study of CTA obtained for preoperative planning of reconstructive microsurgery at both donor and recipient sites study demonstrates that CTA is safe and highly accurate. Computed tomographic angiography can alter the surgeon's reconstructive plan when abnormalities are noted preoperatively and consequently improve results by decreasing vascular complication rates. The use of CTA should be considered for cases of microsurgical reconstruction where the vascular anatomy may be questionable. PMID:24023972
Evaluation of a 3D point cloud tetrahedral tomographic reconstruction method
Pereira, N F; Sitek, A
2011-01-01
Tomographic reconstruction on an irregular grid may be superior to reconstruction on a regular grid. This is achieved through an appropriate choice of the image space model, the selection of an optimal set of points and the use of any available prior information during the reconstruction process. Accordingly, a number of reconstruction-related parameters must be optimized for best performance. In this work, a 3D point cloud tetrahedral mesh reconstruction method is evaluated for quantitative tasks. A linear image model is employed to obtain the reconstruction system matrix and five point generation strategies are studied. The evaluation is performed using the recovery coefficient, as well as voxel- and template-based estimates of bias and variance measures, computed over specific regions in the reconstructed image. A similar analysis is performed for regular grid reconstructions that use voxel basis functions. The maximum likelihood expectation maximization reconstruction algorithm is used. For the tetrahedral reconstructions, of the five point generation methods that are evaluated, three use image priors. For evaluation purposes, an object consisting of overlapping spheres with varying activity is simulated. The exact parallel projection data of this object are obtained analytically using a parallel projector, and multiple Poisson noise realizations of these exact data are generated and reconstructed using the different point generation strategies. The unconstrained nature of point placement in some of the irregular mesh-based reconstruction strategies has superior activity recovery for small, low-contrast image regions. The results show that, with an appropriately generated set of mesh points, the irregular grid reconstruction methods can out-perform reconstructions on a regular grid for mathematical phantoms, in terms of the performance measures evaluated. PMID:20736496
Evaluation of a 3D point cloud tetrahedral tomographic reconstruction method
NASA Astrophysics Data System (ADS)
Pereira, N. F.; Sitek, A.
2010-09-01
Tomographic reconstruction on an irregular grid may be superior to reconstruction on a regular grid. This is achieved through an appropriate choice of the image space model, the selection of an optimal set of points and the use of any available prior information during the reconstruction process. Accordingly, a number of reconstruction-related parameters must be optimized for best performance. In this work, a 3D point cloud tetrahedral mesh reconstruction method is evaluated for quantitative tasks. A linear image model is employed to obtain the reconstruction system matrix and five point generation strategies are studied. The evaluation is performed using the recovery coefficient, as well as voxel- and template-based estimates of bias and variance measures, computed over specific regions in the reconstructed image. A similar analysis is performed for regular grid reconstructions that use voxel basis functions. The maximum likelihood expectation maximization reconstruction algorithm is used. For the tetrahedral reconstructions, of the five point generation methods that are evaluated, three use image priors. For evaluation purposes, an object consisting of overlapping spheres with varying activity is simulated. The exact parallel projection data of this object are obtained analytically using a parallel projector, and multiple Poisson noise realizations of these exact data are generated and reconstructed using the different point generation strategies. The unconstrained nature of point placement in some of the irregular mesh-based reconstruction strategies has superior activity recovery for small, low-contrast image regions. The results show that, with an appropriately generated set of mesh points, the irregular grid reconstruction methods can out-perform reconstructions on a regular grid for mathematical phantoms, in terms of the performance measures evaluated.
NASA Astrophysics Data System (ADS)
Silva, B. Marta; Zaroubi, Saleem; Kooistra, Robin; Cooray, Asantha
2018-04-01
The H α line emission is an important probe for a number of fundamental quantities in galaxies, including their number density, star formation rate (SFR), and overall gas content. A new generation of low-resolution intensity mapping (IM) probes, e.g. SPHEREx and CDIM, will observe galaxies in H α emission over a large fraction of the sky from the local Universe till a redshift of z ˜ 6 - 10, respectively. This will also be the target line for observations by the high-resolution Euclid and WFIRST instruments in the z ˜ 0.7-2 redshift range. In this paper, we estimate the intensity and power spectra of the H α line in the z ˜ 0-5 redshift range using observed line luminosity functions (LFs), when possible, and simulations, otherwise. We estimate the significance of our predictions by accounting for the modelling uncertainties (e.g. SFR, extinction, etc.) and observational contamination. We find that IM surveys can make a statistical detection of the full H α emission between z ˜ 0.8 and 5. Moreover, we find that the high-frequency resolution and the sensitivity of the planned CDIM surveys allow for the separation of H α emission from several interloping lines. We explore ways to use the combination of these line intensities to probe galaxy properties. As expected, our study indicates that galaxy surveys will only detect bright galaxies that contribute up to a few per cent of the overall H α intensity. However, these surveys will provide important constraints on the high end of the H α LF and put strong constraints on the active galactic nucleus LF.
NASA Astrophysics Data System (ADS)
Kostencka, Julianna; Kozacki, Tomasz; Hennelly, Bryan; Sheridan, John T.
2017-06-01
Holographic tomography (HT) allows noninvasive, quantitative, 3D imaging of transparent microobjects, such as living biological cells and fiber optics elements. The technique is based on acquisition of multiple scattered fields for various sample perspectives using digital holographic microscopy. Then, the captured data is processed with one of the tomographic reconstruction algorithms, which enables 3D reconstruction of refractive index distribution. In our recent works we addressed the issue of spatially variant accuracy of the HT reconstructions, which results from the insufficient model of diffraction that is applied in the widely-used tomographic reconstruction algorithms basing on the Rytov approximation. In the present study, we continue investigating the spatially variant properties of the HT imaging, however, we are now focusing on the limited spatial size of holograms as a source of this problem. Using the Wigner distribution representation and the Ewald sphere approach, we show that the limited size of the holograms results in a decreased quality of tomographic imaging in off-center regions of the HT reconstructions. This is because the finite detector extent becomes a limiting aperture that prohibits acquisition of full information about diffracted fields coming from the out-of-focus structures of a sample. The incompleteness of the data results in an effective truncation of the tomographic transfer function for the out-of-center regions of the tomographic image. In this paper, the described effect is quantitatively characterized for three types of the tomographic systems: the configuration with 1) object rotation, 2) scanning of the illumination direction, 3) the hybrid HT solution combing both previous approaches.
Intensity-enhanced MART for tomographic PIV
NASA Astrophysics Data System (ADS)
Wang, HongPing; Gao, Qi; Wei, RunJie; Wang, JinJun
2016-05-01
A novel technique to shrink the elongated particles and suppress the ghost particles in particle reconstruction of tomographic particle image velocimetry is presented. This method, named as intensity-enhanced multiplicative algebraic reconstruction technique (IntE-MART), utilizes an inverse diffusion function and an intensity suppressing factor to improve the quality of particle reconstruction and consequently the precision of velocimetry. A numerical assessment about vortex ring motion with and without image noise is performed to evaluate the new algorithm in terms of reconstruction, particle elongation and velocimetry. The simulation is performed at seven different seeding densities. The comparison of spatial filter MART and IntE-MART on the probability density function of particle peak intensity suggests that one of the local minima of the distribution can be used to separate the ghosts and actual particles. Thus, ghost removal based on IntE-MART is also introduced. To verify the application of IntE-MART, a real plate turbulent boundary layer experiment is performed. The result indicates that ghost reduction can increase the accuracy of RMS of velocity field.
do Nascimento, Felipe Barjud Pereira; dos Santos, Glaucia Aparecida Bento; Melo, Nelson Almeida d'Ávila; Damasceno, Eduarda Bittencourt; Mauad, Thais
2015-09-01
Postmortem computerized tomographic angiography (PMCTA) has been increasingly used in forensic medicine to detect and locate the source of bleeding in cases of fatal acute hemorrhage. In this paper, we report a case of postoperative complication in a patient with a giant juvenile nasopharyngeal angiofibroma in which the source of bleeding was detected by PMCTA. A case description and evaluations of the pre- and postoperative exams, postmortem CT angiogram, and conventional autopsy results are provided. The source of bleeding was identified by postmortem CT angiography but not by conventional autopsy. The established protocol, injecting contrast medium into the femoral artery, was effective in identifying the source of bleeding. Postoperative bleeding is a rare and frequently fatal complication of juvenile nasopharyngeal angiofibroma. As a complement to conventional autopsy, postmortem angiography is a valuable tool for the detection of lethal acute hemorrhagic foci, and establishing a routine procedure for PMCTA may improve its efficiency.
Kim, Joo Young; Lim, Jeongtaek; Lee, JaeHwan; Hwang, Hong-Sik; Lee, Suyong
2017-02-01
Canola oil-carnauba wax oleogels were evaluated as a replacement for shortening in a baked cake system. The use of oleogels produced cake batters with a lower pseudoplastic property and also contributed to their viscous nature. The shortening replacement with oleogels at up to 50% was effective in maintaining the ability to hold air cells into the cake batters. The volume of cakes had an overall tendency to decrease with increasing shortening replacement with oleogels, leading to increased cake firmness. The tomographic analysis demonstrated that the total porosity and fragmentation index were reduced in the oleogel cakes, showing a more connected solid structure. The levels of saturated fatty acids in the cakes containing oleogels were significantly reduced to 13.3%, compared to the control with shortening (74.2%). As a result, the use of oleogels for shortening up to 25% produced cakes with lower levels of saturated fatty acids without quality loss. © 2016 Institute of Food Technologists®.
Umphlet, R C; Johnson, A L; Eurell, J C; Losonsky, J
1988-01-01
Partial rostral hemimandibulectomy was performed in 10 adult dogs. The temporomandibular joints (TMJs) were examined radiographically and tomographically before surgery, and mandibular stability was evaluated before and immediately after surgery. Radiographic, tomographic, and hemimandibular mobility assessments were made again at months 3 and 6. The TMJs were examined grossly and histologically in five dogs euthanatized at month 3 and in five dogs euthanatized at month 6. Statistically significant hemimandibular instability (p less than 0.05) persisted in all subjects throughout the study. The radiographic appearance of the joints remained unaltered; however, space asymmetry was identified in postoperative tomograms of three dogs at month 3 and four dogs at month 6. The TMJs were grossly normal at necropsy. Histologically, there were degenerative changes in articular cartilage and subchondral bone in all of the joints. The authors conclude that partial rostral hemimandibulectomy causes TMJ degeneration, as a consequence of hemimandibular instability or abnormal loading, or both.
Resting-state functional connectivity assessed with two diffuse optical tomographic systems.
Niu, Haijing; Khadka, Sabin; Tian, Fenghua; Lin, Zi-Jing; Lu, Chunming; Zhu, Chaozhe; Liu, Hanli
2011-04-01
Functional near-infrared spectroscopy (fNIRS) is recently utilized as a new approach to assess resting-state functional connectivity (RSFC) in the human brain. For any new technique or new methodology, it is necessary to be able to replicate similar experiments using different instruments in order to establish its liability and reproducibility. We apply two different diffuse optical tomographic (DOT) systems (i.e., DYNOT and CW5), with various probe arrangements to evaluate RSFC in the sensorimotor cortex by utilizing a previously published experimental protocol and seed-based correlation analysis. Our results exhibit similar spatial patterns and strengths in RSFC between the bilateral motor cortexes. The consistent observations are obtained from both DYNOT and CW5 systems, and are also in good agreement with the previous fNIRS study. Overall, we demonstrate that the fNIRS-based RSFC is reproducible by various DOT imaging systems among different research groups, enhancing the confidence of neuroscience researchers and clinicians to utilize fNIRS for future applications.
Phase decomposition and ordering in Ni-11.3 at.% Ti studied with atom probe tomography.
Al-Kassab, T; Kompatscher, M; Kirchheim, R; Kostorz, G; Schönfeld, B
2014-09-01
The decomposition behavior of Ni-rich Ni-Ti was reassessed using Tomographic Atom Probe (TAP) and Laser Assisted Wide Angle Tomographic Atom Probe. Single crystalline specimens of Ni-11.3 at.% Ti were investigated, the states selected from the decomposition path were the metastable γ″ and γ' states introduced on the basis of small-angle neutron scattering (SANS) and the two-phase model for evaluation. The composition values of the precipitates in these states could not be confirmed by APT data as the interface of the ordered precipitates may not be neglected. The present results rather suggest to apply a three-phase model for the interpretation of SANS measurements, in which the width of the interface remains nearly unchanged and the L12 structure close to 3:1 stoichiometry is maintained in the core of the precipitates from the γ″ to the γ' state. Copyright © 2014 Elsevier Ltd. All rights reserved.
Alves, Heitor C; Treurniet, Kilian M; Dutra, Bruna G; Jansen, Ivo G H; Boers, Anna M M; Santos, Emilie M M; Berkhemer, Olvert A; Dippel, Diederik W J; van der Lugt, Aad; van Zwam, Wim H; van Oostenbrugge, Robert J; Lingsma, Hester F; Roos, Yvo B W E M; Yoo, Albert J; Marquering, Henk A; Majoie, Charles B L M
2018-02-01
Thrombus characteristics and collateral score are associated with functional outcome in patients with acute ischemic stroke. It has been suggested that they affect each other. The aim of this study is to evaluate the association between clot burden score, thrombus perviousness, and collateral score and to determine whether collateral score influences the association of thrombus characteristics with functional outcome. Patients with baseline thin-slice noncontrast computed tomography and computed tomographic angiography images from the MR CLEAN trial (Multicenter Randomized Clinical Trial of Endovascular Treatment of Acute Ischemic Stroke in the Netherlands) were included (n=195). Collateral score and clot burden scores were determined on baseline computed tomographic angiography. Thrombus attenuation increase was determined by comparing thrombus density on noncontrast computed tomography and computed tomographic angiography using a semiautomated method. The association of collateral score with clot burden score and thrombus attenuation increase was evaluated with linear regression. Mediation and effect modification analyses were used to assess the influence of collateral score on the association of clot burden score and thrombus attenuation increase with functional outcome. A higher clot burden score (B=0.063; 95% confidence interval, 0.008-0.118) and a higher thrombus attenuation increase (B=0.014; 95% confidence interval, 0.003-0.026) were associated with higher collateral score. Collateral score mediated the association of clot burden score with functional outcome. The association between thrombus attenuation increase and functional outcome was modified by the collateral score, and this association was stronger in patients with moderate and good collaterals. Patients with lower thrombus burden and higher thrombus perviousness scores had higher collateral score. The positive effect of thrombus perviousness on clinical outcome was only present in patients with moderate and high collateral scores. URL: http://www.trialregister.nl. Unique identifier: NTR1804 and URL: http://www.controlled-trials.com Unique identifier: ISRCTN10888758. © 2018 The Authors.
Lin, Hsiu-Hsia; Chuang, Ya-Fang; Weng, Jing-Ling; Lo, Lun-Jou
2015-01-01
Background Three-dimensional computed tomographic imaging has become popular in clinical evaluation, treatment planning, surgical simulation, and outcome assessment for maxillofacial intervention. The purposes of this study were to investigate whether there is any correlation among landmark-based horizontal reference planes and to validate the reproducibility and reliability of landmark identification. Materials and Methods Preoperative and postoperative cone-beam computed tomographic images of patients who had undergone orthognathic surgery were collected. Landmark-oriented reference planes including the Frankfort horizontal plane (FHP) and the lateral semicircular canal plane (LSP) were established. Four FHPs were defined by selecting 3 points from the orbitale, porion, or midpoint of paired points. The LSP passed through both the lateral semicircular canal points and nasion. The distances between the maxillary or mandibular teeth and the reference planes were measured, and the differences between the 2 sides were calculated and compared. The precision in locating the landmarks was evaluated by performing repeated tests, and the intraobserver reproducibility and interobserver reliability were assessed. Results A total of 30 patients with facial deformity and malocclusion—10 patients with facial symmetry, 10 patients with facial asymmetry, and 10 patients with cleft lip and palate—were recruited. Comparing the differences among the 5 reference planes showed no statistically significant difference among all patient groups. Regarding intraobserver reproducibility, the mean differences in the 3 coordinates varied from 0 to 0.35 mm, with correlation coefficients between 0.96 and 1.0, showing high correlation between repeated tests. Regarding interobserver reliability, the mean differences among the 3 coordinates varied from 0 to 0.47 mm, with correlation coefficients between 0.88 and 1.0, exhibiting high correlation between the different examiners. Conclusions The 5 horizontal reference planes were reliable and comparable for 3D craniomaxillofacial analysis. These reference planes were useful in standardizing the orientation of 3D skull models. PMID:25668209
Lin, Hsiu-Hsia; Chuang, Ya-Fang; Weng, Jing-Ling; Lo, Lun-Jou
2015-01-01
Three-dimensional computed tomographic imaging has become popular in clinical evaluation, treatment planning, surgical simulation, and outcome assessment for maxillofacial intervention. The purposes of this study were to investigate whether there is any correlation among landmark-based horizontal reference planes and to validate the reproducibility and reliability of landmark identification. Preoperative and postoperative cone-beam computed tomographic images of patients who had undergone orthognathic surgery were collected. Landmark-oriented reference planes including the Frankfort horizontal plane (FHP) and the lateral semicircular canal plane (LSP) were established. Four FHPs were defined by selecting 3 points from the orbitale, porion, or midpoint of paired points. The LSP passed through both the lateral semicircular canal points and nasion. The distances between the maxillary or mandibular teeth and the reference planes were measured, and the differences between the 2 sides were calculated and compared. The precision in locating the landmarks was evaluated by performing repeated tests, and the intraobserver reproducibility and interobserver reliability were assessed. A total of 30 patients with facial deformity and malocclusion--10 patients with facial symmetry, 10 patients with facial asymmetry, and 10 patients with cleft lip and palate--were recruited. Comparing the differences among the 5 reference planes showed no statistically significant difference among all patient groups. Regarding intraobserver reproducibility, the mean differences in the 3 coordinates varied from 0 to 0.35 mm, with correlation coefficients between 0.96 and 1.0, showing high correlation between repeated tests. Regarding interobserver reliability, the mean differences among the 3 coordinates varied from 0 to 0.47 mm, with correlation coefficients between 0.88 and 1.0, exhibiting high correlation between the different examiners. The 5 horizontal reference planes were reliable and comparable for 3D craniomaxillofacial analysis. These reference planes were useful in standardizing the orientation of 3D skull models.
Ichikawa, Makoto; Sato, Yuichi; Komatsu, Sei; Hirayama, Atsushi; Kodama, Kazuhisa; Saito, Satoshi
2007-06-01
Anomalous right coronary arteries (RCA) arising from the left sinus of Valsalva may cause myocardial ischemia. We evaluated morphological features of anomalous RCA by using multislice computed tomography (MSCT) in relation to myocardial ischemia provoked by myocardial perfusion single-photon emission computed tomography. MSCT was performed in a total of 3, 212 patients by using an Aquillion 16 and a Light Speed Ultra. Retrospective ECG-gated image reconstruction was performed. Volume rendering, axial and curved multiplanar reformatted images were analyzed for the determination of the origin and course of the RCA, the take-off angle of the RCA from the aorta, and size of the RCA orifice. Furthermore, virtual angioscopic images were also used for the evaluation of the RCA orifice structure. Anomalous origins of the RCA were found in 15 patients. In 13 patients, the RCA arose from the left sinus of Valsalva, and in 2 patients it arose from the left main coronary artery as a single coronary artery. The RCA coursed anteriorly between the ascending aorta and pulmonary artery in 14 patients, whereas it had a retroaortic course in 1 patient. Acute angle take-off (<30 degrees ) of the RCA from the aorta and the left main coronary artery was observed in 8 patients, intramural course of the RCA within the aortic wall was observed in 6 patients and a small RCA orifice was observed in 4 patients. Exercise-induced myocardial ischemia was present in 5 patients. Coursing between the aorta and pulmonary artery, acute angle take-off and intramural course were thought to be major causes of exercise-induced ischemia in patients with anomalous origins of the RCA.
Performance evaluation of neuro-PET using silicon photomultipliers
NASA Astrophysics Data System (ADS)
Jung, Jiwoong; Choi, Yong; Jung, Jin Ho; Kim, Sangsu; Im, Ki Chun
2016-05-01
Recently, we have developed the second prototype Silicon photomultiplier (SiPM) based positron emission tomography (PET) scanner for human brain imaging. The PET system was comprised of detector block which consisted of 4×4 SiPMs and 4×4 Lutetium Yttrium Orthosilicate arrays, charge signal transmission method, high density position decoder circuit and FPGA-embedded ADC boards. The purpose of this study was to evaluate the performance of the newly developed neuro-PET system. The energy resolution, timing resolution, spatial resolution, sensitivity, stability of the photo-peak position and count rate performance were measured. Tomographic image of 3D Hoffman brain phantom was also acquired to evaluate imaging capability of the neuro-PET. The average energy and timing resolutions measured for 511 keV gamma rays were 17±0.1% and 3±0.3 ns, respectively. Spatial resolution and sensitivity at the center of field of view (FOV) were 3.1 mm and 0.8%, respectively. The average scatter fraction was 0.4 with an energy window of 350-650 keV. The maximum true count rate and maximum NECR were measured as 43.3 kcps and 6.5 kcps at an activity concentration of 16.7 kBq/ml and 5.5 kBq/ml, respectively. Long-term stability results show that there was no significant change in the photo-peak position, energy resolution and count rate for 60 days. Phantom imaging studies were performed and they demonstrated the feasibility for high quality brain imaging. The performance tests and imaging results indicate that the newly developed PET is useful for brain imaging studies, if the axial FOV is extended to improve the system sensitivity.
NASA Astrophysics Data System (ADS)
Kosch, Michael; Bristow, Bill; Gustavsson, Bjorn; Heinselman, Craig; Hughes, John; Isham, Brett; Mutiso, Charles; Nielsen, Kim; Pedersen, Todd; Wang, Weiyuan; Wong, Alfred
We report results from a unique experiment performed at the HIPAS ionospheric modification facility in Alaska. High power radio waves at 2.85 MHz, which corresponds to the second electron gyroharmonic at 240 km altitude, were transmitted into the nighttime ionosphere. Diagnostics included optical equipment at HIPAS and HAARP, 288 km to the south-east, the PFISR radar at Poker Flat, 32 km to the north-west, and the Kodiak SuperDARN radar, 856 km to the south-west. Camera observations of the stimulated optical emissions at 557.7 nm (O1S, threshold 4.2 eV) and 630 nm (O1D, threshold 2 eV) were made, allowing tomographic reconstruction of the volume emission. The first observations of pump-induced 732 nm (O+, threshold 18.6 eV) emissions are reported. Kodiak radar backscatter, which is a proxy for upper-hybrid resonance, shows strong production of striations without a minimum on the second gyroharmonic, confirming previous results. PFISR analysis shows clear evidence of electron temperature enhancements, consistent with previous EISCAT results, maximizing when the pump frequency matches the second gyroharmonic and when double resonance occurs, i.e. the upper-hybrid resonance frequency matches the second gyroharmonic. This is consistent with the optical observations. From the above data, we are able to infer the efficiency of different groups of electron-accelerating mechanisms.
TOmographic Remote Observer of Ionospheric Disturbances
2007-11-15
ionosphere . The proposed spacecraft was an evolutionary design from the USUSat, Combat Sentinel, and USUSat II programs whose histories are shown in...Figure 1. The primary science instrument, TOROID for TOmographic Remote Observer of Ionospheric Disturbances, is a photometer for measuring the
Acoustic representation of tomographic data
NASA Astrophysics Data System (ADS)
Wampler, Cheryl; Zahrt, John D.; Hotchkiss, Robert S.; Zahrt, Rebecca; Kust, Mark
1993-04-01
Tomographic data and tomographic reconstructions are naturally periodic in the angle of rotation of the turntable and the polar angel of the coordinates in the object, respectively. Similarly, acoustic waves are periodic and have amplitude and wavelength as free parameters that can be fit to another representation. Work has been in progress for some time in bringing the acoustic senses to bear on large data sets rather than just the visual sense. We will provide several different acoustic representations of both raw data and density maps. Rather than graphical portrayal of the data and reconstructions, you will be presented various 'tone poems.'
Optical tomograph optimized for tumor detection inside highly absorbent organs
NASA Astrophysics Data System (ADS)
Boutet, Jérôme; Koenig, Anne; Hervé, Lionel; Berger, Michel; Dinten, Jean-Marc; Josserand, Véronique; Coll, Jean-Luc
2011-05-01
This paper presents a tomograph for small animal fluorescence imaging. The compact and cost-effective system described in this article was designed to address the problem of tumor detection inside highly absorbent heterogeneous organs, such as lungs. To validate the tomograph's ability to detect cancerous nodules inside lungs, in vivo tumor growth was studied on seven cancerous mice bearing murine mammary tumors marked with Alexa Fluor 700. They were successively imaged 10, 12, and 14 days after the primary tumor implantation. The fluorescence maps were compared over this time period. As expected, the reconstructed fluorescence increases with the tumor growth stage.
Lamb wave tomographic imaging system for aircraft structural health assessment
NASA Astrophysics Data System (ADS)
Schwarz, Willi G.; Read, Michael E.; Kremer, Matthew J.; Hinders, Mark K.; Smith, Barry T.
1999-01-01
A tomographic imaging system using ultrasonic Lamb waves for the nondestructive inspection of aircraft components such as wings and fuselage is being developed. The computer-based system provides large-area inspection capability by electronically scanning an array of transducers that can be easily attached to flat and curved surface without moving parts. Images of the inspected area are produced in near real time employing a tomographic reconstruction method adapted from seismological applications. Changes in material properties caused by structural flaws such as disbonds, corrosion, and fatigue cracks can be effectively detected and characterized utilizing this fast NDE technique.
Sodankylä ionospheric tomography dataset 2003-2014
NASA Astrophysics Data System (ADS)
Norberg, J.; Roininen, L.; Kero, A.; Raita, T.; Ulich, T.; Markkanen, M.; Juusola, L.; Kauristie, K.
2015-12-01
Sodankylä Geophysical Observatory has been operating a tomographic receiver network and collecting the produced data since 2003. The collected dataset consists of phase difference curves measured from Russian COSMOS dual-frequency (150/400 MHz) low-Earth-orbit satellite signals, and tomographic electron density reconstructions obtained from these measurements. In this study vertical total electron content (VTEC) values are integrated from the reconstructed electron densities to make a qualitative and quantitative analysis to validate the long-term performance of the tomographic system. During the observation period, 2003-2014, there were three-to-five operational stations at the Fenno-Scandinavian sector. Altogether the analysis consists of around 66 000 overflights, but to ensure the quality of the reconstructions, the examination is limited to cases with descending (north to south) overflights and maximum elevation over 60°. These constraints limit the number of overflights to around 10 000. Based on this dataset, one solar cycle of ionospheric vertical total electron content estimates is constructed. The measurements are compared against International Reference Ionosphere IRI-2012 model, F10.7 solar flux index and sunspot number data. Qualitatively the tomographic VTEC estimate corresponds to reference data very well, but the IRI-2012 model are on average 40 % higher of that of the tomographic results.
Computerized tomographic determination of spinal bone mineral content
NASA Technical Reports Server (NTRS)
Cann, C. E.; Genant, H. K.
1980-01-01
The aims of the study were three-fold: to determine the magnitude of vertebral cancellous mineral loss in normal subjects during bedrest, to compare this loss with calcium balance and mineral loss in peripheral bones, and to use the vertebral measurements as an evaluative criterion for the C12MDP treatment and compare it with other methods. The methods used are described and the results from 14 subjects are presented.
Computed tomographic identification of calcified optic nerve drusen
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ramirez, H.; Blatt, E.S.; Hibri, N.S.
1983-07-01
Four cases of optic disk drusen were accurately diagnosed with orbital computed tomography (CT). The radiologist should be aware of the characteristic CT finding of discrete calcification within an otherwise normal optic disk. This benign process is easily differentiated from lesions such as calcific neoplastic processes of the posterior globe. CT identification of optic disk drusen is essential in the evaluation of visual field defects, migraine-like headaches, and pseudopapilledema.
Repplinger, Michael D; Nagle, Scott K; Harringa, John B; Broman, Aimee T; Lindholm, Christopher R; François, Christopher J; Grist, Thomas M; Reeder, Scott B; Schiebler, Mark L
2018-05-10
To compare patient outcomes following magnetic resonance angiography (MRA) versus computed tomographic angiography (CTA) ordered for suspected pulmonary embolism (PE). In this IRB-approved, single-center, retrospective, case-control study, we reviewed the medical records of all patients evaluated for PE with MRA during a 5-year period along with age- and sex-matched controls evaluated with CTA. Only the first instance of PE evaluation during the study period was included. After application of our exclusion criteria to both study arms, the analysis included 1173 subjects. The primary endpoint was major adverse PE-related event (MAPE), which we defined as major bleeding, venous thromboembolism, or death during the 6 months following the index imaging test (MRA or CTA), obtained through medical record review. Logistic regression, chi-square test for independence, and Fisher's exact test were used with a p < 0.05 threshold. The overall 6-month MAPE rate following MRA (5.4%) was lower than following CTA (13.6%, p < 0.01). Amongst outpatients, the MAPE rate was lower for MRA (3.7%) than for CTA (8.0%, p = 0.01). Accounting for age, sex, referral source, BMI, and Wells' score, patients were less likely to suffer MAPE than those who underwent CTA, with an odds ratio of 0.44 [0.24, 0.80]. Technical success rate did not differ significantly between MRA (92.6%) and CTA (90.5%) groups (p = 0.41). Within the inherent limitations of a retrospective case-controlled analysis, we observed that the rate of MAPE was lower (more favorable) for patients following pulmonary MRA for the primary evaluation of suspected PE than following CTA.
Abe, Masanori; Fukazawa, Ryuji; Ogawa, Shunichi; Watanabe, Makoto; Fukushima, Yoshimitsu; Kiriyama, Tomonari; Hayashi, Hiromitsu; Itoh, Yasuhiko
2016-01-01
The coronary arterial lesions of Kawasaki disease are mainly dilative lesions, aneurysms, and stenotic lesions formed before, after, and between aneurysms; these lesions develop in multiple branches resulting in complex coronary hemodynamics. Diagnosis of myocardial ischemia and infarction and evaluation of the culprit coronary arteries and regions is critical to evaluating the treatment and prognosis of patients. This study used hybrid imaging, in which multidetector computed tomographic (CT) images for coronary CT angiography (CCTA) and stress myocardial perfusion single-photon emission CT (SPECT) images were fused. We investigated the diagnosis of blood vessels and regions responsible for myocardial ischemia and infarction in patients with complex coronary arterial lesions; in addition, we evaluated myocardial lesions that developed directly under giant coronary artery aneurysms. The subjects were 17 patients with Kawasaki disease with multiple coronary arterial lesions (median age, 18.0 years; 16 male). Both CCTA using 64-row CT and adenosine-loading myocardial SPECT were performed. Three branches, the right coronary artery (RCA), left anterior descending branch (LAD), and left circumflex branch, were evaluated with the conventional side-by-side interpretation, in which the images were lined up for diagnosis, and hybrid imaging, in which the CCTA and SPECT images were fused with computer processing. In addition, the myocardial lesions directly under giant coronary artery aneurysms were investigated with fusion imaging. Images sufficient for evaluation were acquired in all 17 patients. In the RCA, coronary arterial lesions were detected with CCTA in 16 patients. The evaluations were consistent between the side-by-side and fusion interpretation in 14 patients, and the blood vessel responsible for the myocardial ischemic region was identified in 2 patients. In the left circumflex branch, coronary arterial lesions were confirmed with 3-dimensional CT in 5 patients, and the the culprit coronary arteries for myocardial ischemia/infarction were confirmed with the fusion interpretation but not with the side-by-side interpretation. In the LAD, coronary arterial lesions were present in all patients, and the diagnosis was made with the fusion interpretation in 10 patients. In the LAD, small-range infarct lesions were detected directly under the giant coronary artery aneurysm in 8 patients, but were not confirmed with the side-by-side interpretation. Fusion imaging was capable of accurately evaluating myocardial ischemia/infarction as cardiovascular sequelae of Kawasaki disease and confirming the culprit coronary arteries. In addition, analysis of fusion images confirmed that small-range infarct lesions were concomitantly present directly under giant coronary artery aneurysms in the anterior descending coronary artery.
Van Laere, Koen; Vanhee, Annelies; Verschueren, Jolien; De Coster, Liesbeth; Driesen, An; Dupont, Patrick; Robberecht, Wim; Van Damme, Philip
2014-05-01
Amyotrophic lateral sclerosis (ALS) is a neurodegenerative disorder primarily affecting the motor system, with extramotor involvement to a variable extent. Biomarkers for early differential diagnosis and prognosis are needed. An autosomal dominant hexanucleotide (GGGGCC) expansion in the noncoding region of the chromosome 9 open reading frame 72 (C9orf72) gene is the most frequent genetic cause of ALS, but its metabolic pattern has not been studied systematically. To evaluate the use of 18fluorodeoxyglucose-positron-emission tomography as a marker of ALS pathology and investigate whether a specific metabolic signature is present in patients with C9orf72 mutations. In total, 81 patients with a suspected diagnosis of ALS at University Hospital Leuven were prospectively investigated. All underwent detailed neurological examination and electrodiagnostic and genetic testing for the major known genetic causes of ALS (C9orf72, SOD1, TARDBP, and FUS). A diagnosis of ALS was made in 70 of 81 patients. Of these, 11 were C9orf72 positive and 59 were C9orf72 negative. In 7 patients, the diagnosis of primary lateral sclerosis was made; 4 patients had progressive muscular atrophy. A screened healthy control population was used for comparison. Positron-emission tomographic data were spatially normalized and analyzed using a predefined volume of interest and a voxel-based analysis (SPM8). Discriminant analysis was done both volume of interest based and voxel based using a support vector machine approach. Compared with control participants, 18fluorodeoxyglucose-positron-emission tomography showed perirolandic and variable prefrontal hypometabolism in most patients. Patients with primary lateral sclerosis showed a similar pattern. Patients with C9orf72-positive ALS had discrete relative hypometabolism in the thalamus and posterior cingulate compared with those with C9orf72-negative ALS. A posteriori-corrected discriminant analysis was able to correctly classify 95% of ALS cases and 71% of primary lateral sclerosis cases. Prefrontal hypometabolism was associated with reduced clinical functioning (ALS Functional Rating Scale). Extensive hypometabolism in the prefrontal or anterior temporal areas was present in 10% of patients and associated with significantly shorter survival as an independent factor (n = 63, P < .001). Patients who were C9orf72 positive did not differ in survival compared with those who were C9orf72 negative. 18Fluorodeoxyglucose-positron-emission tomography is a useful early diagnostic and prognostic marker for ALS. Amyotrophic lateral sclerosis that is positive for C9orf72 is characterized by only mild cerebral metabolic differences that show no prognostic difference.
The Mathematics of Four or More N-Localizers for Stereotactic Neurosurgery.
Brown, Russell A
2015-10-13
The mathematics that were originally developed for the N-localizer apply to three N-localizers that produce three sets of fiducials in a tomographic image. Some applications of the N-localizer use four N-localizers that produce four sets of fiducials; however, the mathematics that apply to three sets of fiducials do not apply to four sets of fiducials. This article presents mathematics that apply to four or more sets of fiducials that all lie within one planar tomographic image. In addition, these mathematics are extended to apply to four or more fiducials that do not all lie within one planar tomographic image, as may be the case with magnetic resonance (MR) imaging where a volume is imaged instead of a series of planar tomographic images. Whether applied to a planar image or a volume image, the mathematics of four or more N-localizers provide a statistical measure of the quality of the image data that may be influenced by factors, such as the nonlinear distortion of MR images.
TomoBank: a tomographic data repository for computational x-ray science
De Carlo, Francesco; Gürsoy, Doğa; Ching, Daniel J.; ...
2018-02-08
There is a widening gap between the fast advancement of computational methods for tomographic reconstruction and their successful implementation in production software at various synchrotron facilities. This is due in part to the lack of readily available instrument datasets and phantoms representative of real materials for validation and comparison of new numerical methods. Recent advancements in detector technology made sub-second and multi-energy tomographic data collection possible [1], but also increased the demand to develop new reconstruction methods able to handle in-situ [2] and dynamic systems [3] that can be quickly incorporated in beamline production software [4]. The X-ray Tomography Datamore » Bank, tomoBank, provides a repository of experimental and simulated datasets with the aim to foster collaboration among computational scientists, beamline scientists, and experimentalists and to accelerate the development and implementation of tomographic reconstruction methods for synchrotron facility production software by providing easy access to challenging dataset and their descriptors.« less
High-resolution multimodal clinical multiphoton tomography of skin
NASA Astrophysics Data System (ADS)
König, Karsten
2011-03-01
This review focuses on multimodal multiphoton tomography based on near infrared femtosecond lasers. Clinical multiphoton tomographs for 3D high-resolution in vivo imaging have been placed into the market several years ago. The second generation of this Prism-Award winning High-Tech skin imaging tool (MPTflex) was introduced in 2010. The same year, the world's first clinical CARS studies have been performed with a hybrid multimodal multiphoton tomograph. In particular, non-fluorescent lipids and water as well as mitochondrial fluorescent NAD(P)H, fluorescent elastin, keratin, and melanin as well as SHG-active collagen has been imaged with submicron resolution in patients suffering from psoriasis. Further multimodal approaches include the combination of multiphoton tomographs with low-resolution wide-field systems such as ultrasound, optoacoustical, OCT, and dermoscopy systems. Multiphoton tomographs are currently employed in Australia, Japan, the US, and in several European countries for early diagnosis of skin cancer, optimization of treatment strategies, and cosmetic research including long-term testing of sunscreen nanoparticles as well as anti-aging products.
Nuclear medicine in clinical neurology: an update
DOE Office of Scientific and Technical Information (OSTI.GOV)
Oldendorf, W.H.
1981-01-01
Isotope scanning using technetium 99m pertechnetate has fallen into disuse since the advent of x-ray computerized tomography. Regional brain blood flow studies have been pursued on a research basis. Increased regional blood flow during focal seizure activity has been demonstrated and is of use in localizing such foci. Cisternography as a predictive tool in normal pressure hydrocephalus is falling into disuse. Positron tomographic scanning is a potent research tool that can demonstrate both regional glycolysis and blood flow. Unfortunately, it is extremely expensive and complex to apply in a clinical setting. With support from the National Institutes of Health, sevenmore » extramural centers have been funded to develop positron tomographic capabilities, and they will greatly advance our knowledge of stroke pathophysiology, seizure disorders, brain tumors, and various degenerative diseases. Nuclear magnetic resonance imaging is a potentially valuable tool since it creates tomographic images representing the distribution of brain water. No tissue ionization is produced, and images comparable to second-generation computerized tomographic scans are already being produced in humans.« less
Mudgil, Shikha P; Wise, Scott W; Hopper, Kenneth D; Kasales, Claudia J; Mauger, David; Fornadley, John A
2002-02-01
The correlation between facial and/or head pain in patients clinically suspected of having sinusitis and actual localized findings on sinus computed tomographic (CT) imaging are poorly understood. To prospectively evaluate the relationship of paranasal sinus pain symptoms with CT imaging. Two hundred consecutive patients referred by otolaryngologists and internists for CT of the paranasal sinuses participated by completing a questionnaire immediately before undergoing CT. Three radiologists blinded to the patients' responses scored the degree of air/fluid level, mucosal thickening, bony reaction, and mucus retention cysts using a graded scale of severity (0 to 3 points). The osteomeatal complexes and nasolacrimal ducts were also evaluated for patency. Bivariate analysis was performed to evaluate the relationship between patients' localized symptoms and CT findings in the respective sinus. One hundred sixty-three patients (82%) reported having some form of facial pain or headache. The right temple/forehead was the most frequently reported region of maximal pain. On CT imaging the maxillary sinus was the most frequently involved sinus. Bivariate analysis failed to show any relationship between patient symptoms and findings on CT. Patients with a normal CT reported a mean 5.88 sites of facial or head pain versus 5.45 sites for patients with an abnormal CT. Patient-based responses of sinonasal pain symptoms fail to correlate with findings in the respective sinuses. CT should therefore be reserved for delineating the anatomy and degree of sinus disease before surgical intervention.
Wery, M F; Nada, R M; van der Meulen, J J; Wolvius, E B; Ongkosuwito, E M
2015-03-01
There is little anteroposterior growth of the midface in patients with syndromic craniosynostosis who are followed up over time without intervention. A Le Fort III with distraction osteogenesis can be done to correct this. This is a controlled way in which to achieve appreciable stable advancement of the midface without the need for bone grafting, but the vector of the movement is not always predictable. The purpose of this study was to evaluate the 3-dimensional effect of Le Fort III distraction osteogenesis with an external frame. Ten patients (aged 7-19 years) who had the procedure were included in the study. The le Fort III procedure and the placement of the external frame were followed by an activation period and then a 3-month retention period. Computed tomographic (CT) images taken before and after operation were converted and loaded into 3-dimensional image rendering software and compared with the aid of a paired sample t test and a colour-coded qualitative analysis. Comparison of the CT data before and after distraction indicated that the amount of midface advancement was significant. Le Fort III distraction osteogenesis is an effective way to advance the midface. However, the movement during osteogenesis is not always exactly in the intended direction, and a secondary operation is often necessary. Three-dimensional evaluation over a longer period of time is necessary. Copyright © 2015 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.
Tomographic findings of acute pulmonary toxoplasmosis in immunocompetent patients.
de Souza Giassi, Karina; Costa, Andre Nathan; Apanavicius, Andre; Teixeira, Fernando Bin; Fernandes, Caio Julio Cesar; Helito, Alfredo Salim; Kairalla, Ronaldo Adib
2014-11-25
Toxoplasmosis is one of the most common human zoonosis, and is generally benign in most of the individuals. Pulmonary involvement is common in immunocompromised subjects, but very rare in immunocompetents and there are scarce reports of tomographic findings in the literature. The aim of the study is to describe three immunocompetent patients diagnosed with acute pulmonary toxoplasmosis and their respective thoracic tomographic findings. Acute toxoplasmosis was diagnosed according to the results of serological tests suggestive of recent primary infection and the absence of an alternative etiology. From 2009 to 2013, three patients were diagnosed with acute respiratory failure secondary to acute toxoplasmosis. The patients were two female and one male, and were 38, 56 and 36 years old. Similarly they presented a two-week febrile illness and progressive dyspnea before admission. Laboratory tests demonstrated lymphocytosis, slight changes in liver enzymes and high inflammatory markers. Tomographic findings were bilateral smooth septal and peribronchovascular thickening (100%), ground-glass opacities (100%), atelectasis (33%), random nodules (33%), lymph node enlargement (33%) and pleural effusion (66%). All the patients improved their symptoms after treatment, and complete resolution of tomographic findings were found in the followup. These cases provide a unique description of the presentation and evolution of pulmonary tomographic manifestations of toxoplasmosis in immunocompetent patients. Toxoplasma pneumonia manifests with fever, dyspnea and a non-productive cough that may result in respiratory failure. In animal models, changes were described as interstitial pneumonitis with focal infiltrates of neutrophils that can finally evolve into a pattern of diffuse alveolar damage with focal necrosis. The tomographic findings are characterized as ground glass opacities, smooth septal and marked peribronchovascular thickening; and may mimic pulmonary congestion, lymphangitis, atypical pneumonia and pneumocystosis. This is the largest series of CT findings of acute toxoplasmosis in immunocompetent hosts, and the diagnosis should be considered as patients that present with acute respiratory failure in the context of a subacute febrile illness with bilateral and diffuse interstitial infiltrates with marked peribronchovascular thickening. If promptly treated, pulmonary toxoplasmosis can result in complete clinical and radiological recovery in immunocompetent hosts.
Verbal fluency and positron emission tomographic mapping of regional cerebral glucose metabolism.
Boivin, M J; Giordani, B; Berent, S; Amato, D A; Lehtinen, S; Koeppe, R A; Buchtel, H A; Foster, N L; Kuhl, D E
1992-06-01
Impairment in verbal fluency (VF) has been a consistently reported clinical feature of focal cerebral deficits in frontal and temporal regions. More recent behavioral activation studies with healthy control subjects using positron emission tomography (PET), however, have noted a negative correlation between performance on verbal fluency tasks and regional cortical activity. To see if this negative relationship extends to steady-state non-activation PET measures, thirty-three healthy adults were given a VF task within a day of their 18F-2-fluoro-2-deoxy-D-glucose PET scan. VF was found to correlate positively with left temporal cortical region metabolic activity but to correlate negatively with right and left frontal activity. VF was not correlated significantly with right temporal cortical metabolic activity. Some previous studies with normals using behavioral activation paradigms and PET have reported negative correlations between metabolic activity and cognitive performance similar to that reported here. An explanation for the disparate relationships that were observed between frontal and temporal brain areas and VF might be found in the mediation of different task demands by these separate locations, i.e., task planning and/or initiation by frontal regions and verbal memory by the left temporal area.
NASA Astrophysics Data System (ADS)
Rahman, Tasneem; Tahtali, Murat; Pickering, Mark R.
2015-03-01
Radiolabeled tracer distribution imaging of gamma rays using pinhole collimation is considered promising for small animal imaging. The recent availability of various radiolabeled tracers has enhanced the field of diagnostic study and is simultaneously creating demand for high resolution imaging devices. This paper presents analyses to represent the optimized parameters of a high performance pinhole array detector module using two different characteristics phantoms. Monte Carlo simulations using the Geant4 application for tomographic emission (GATE) were executed to assess the performance of a four head SPECT system incorporated with pinhole array collimators. The system is based on a pixelated array of NaI(Tl) crystals coupled to an array of position sensitive photomultiplier tubes (PSPMTs). The detector module was simulated to have 48 mm by 48 mm active area along with different pinhole apertures on a tungsten plate. The performance of this system has been evaluated using a uniform shape cylindrical water phantom along with NEMA NU-4 image quality (IQ) phantom filled with 99mTc labeled radiotracers. SPECT images were reconstructed where activity distribution is expected to be well visualized. This system offers the combination of an excellent intrinsic spatial resolution, good sensitivity and signal-to-noise ratio along with high detection efficiency over an energy range between 20-160 keV. Increasing number of heads in a stationary system configuration offers increased sensitivity at a spatial resolution similar to that obtained with the current SPECT system design with four heads.
Derenzo, Stephen E.; Budinger, Thomas F.
1984-01-01
In brief, the invention is a tomograph modified to be in a clamshell configuration so that the ring or rings may be moved to multiple sampling positions. The tomograph includes an array of detectors arranged in successive adjacent relative locations along a closed curve in a first position in a selected plane, and means for securing the detectors in the relative locations in a first sampling position. The securing means is movable in the plane in two sections and pivotable at one p The U.S. Government has rights in this invention pursuant to Contract No. W-7405-ENG-48 between the U.S. Department of Energy and the University of California.
Center-of-Mass Tomography and Wigner Function for Multimode Photon States
NASA Astrophysics Data System (ADS)
Dudinets, Ivan V.; Man'ko, Vladimir I.
2018-06-01
Tomographic probability representation of multimode electromagnetic field states in the scheme of center-of-mass tomography is reviewed. Both connection of the field state Wigner function and observable Weyl symbols with the center-of-mass tomograms as well as connection of the Grönewold kernel with the center-of-mass tomographic kernel determining the noncommutative product of the tomograms are obtained. The dual center-of-mass tomogram of the photon states are constructed and the dual tomographic kernel is obtained. The models of other generalized center-of-mass tomographies are discussed. Example of two-mode even and odd Schrödinger cat states is presented in details.
Statistical reconstruction for cosmic ray muon tomography.
Schultz, Larry J; Blanpied, Gary S; Borozdin, Konstantin N; Fraser, Andrew M; Hengartner, Nicolas W; Klimenko, Alexei V; Morris, Christopher L; Orum, Chris; Sossong, Michael J
2007-08-01
Highly penetrating cosmic ray muons constantly shower the earth at a rate of about 1 muon per cm2 per minute. We have developed a technique which exploits the multiple Coulomb scattering of these particles to perform nondestructive inspection without the use of artificial radiation. In prior work [1]-[3], we have described heuristic methods for processing muon data to create reconstructed images. In this paper, we present a maximum likelihood/expectation maximization tomographic reconstruction algorithm designed for the technique. This algorithm borrows much from techniques used in medical imaging, particularly emission tomography, but the statistics of muon scattering dictates differences. We describe the statistical model for multiple scattering, derive the reconstruction algorithm, and present simulated examples. We also propose methods to improve the robustness of the algorithm to experimental errors and events departing from the statistical model.
Takabayashi, Takeshi; Mochizuki, Toshiaki; Otani, Norio; Nishiyama, Kei; Ishimatsu, Shinichi
2014-12-01
The prevalence of anisakiasis is rare in the United States and Europe compared with that in Japan, with few reports of its presentation in the emergency department (ED). This study describes the clinical, hematologic, computed tomographic (CT) characteristics, and treatment in gastric and small intestinal anisakiasis patients in the ED. We retrospectively reviewed the data of 83 consecutive anisakiasis presentations in our ED between 2003 and 2012. Gastric anisakiasis was endoscopically diagnosed with the Anisakis polypide. Small intestinal anisakiasis was diagnosed based on both hematologic (Anisakis antibody) and CT findings. Of the 83 cases, 39 had gastric anisakiasis and 44 had small intestinal anisakiasis based on our diagnostic criteria. Although all patients had abdominal pain, the gastric anisakiasis group developed symptoms significantly earlier (peaking within 6 hours) than the small intestinal anisakiasis group (peaking within 48 hours), and fewer patients with gastric anisakiasis needed admission therapy (5% vs 57%, P<.01). All patients in the gastric and 40 (91%) in the small intestinal anisakiasis group had a history of raw seafood ingestion. Computed tomographic findings revealed edematous wall thickening in all patients, and ascites and phlegmon of the mesenteric fat were more frequently observed in the small intestinal anisakiasis group. In the ED, early and accurate diagnosis of anisakiasis is important to treat and explain to the patient, and diagnosis can be facilitated by a history of raw seafood ingestion, evaluation of the time-to-symptom development, and classic CT findings. Copyright © 2014 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Bruns, S.; Stipp, S. L. S.; Sørensen, H. O.
2017-07-01
X-ray micro- and nanotomography has evolved into a quantitative analysis tool rather than a mere qualitative visualization technique for the study of porous natural materials. Tomographic reconstructions are subject to noise that has to be handled by image filters prior to quantitative analysis. Typically, denoising filters are designed to handle random noise, such as Gaussian or Poisson noise. In tomographic reconstructions, noise has been projected from Radon space to Euclidean space, i.e. post reconstruction noise cannot be expected to be random but to be correlated. Reconstruction artefacts, such as streak or ring artefacts, aggravate the filtering process so algorithms performing well with random noise are not guaranteed to provide satisfactory results for X-ray tomography reconstructions. With sufficient image resolution, the crystalline origin of most geomaterials results in tomography images of objects that are untextured. We developed a denoising framework for these kinds of samples that combines a noise level estimate with iterative nonlocal means denoising. This allows splitting the denoising task into several weak denoising subtasks where the later filtering steps provide a controlled level of texture removal. We describe a hands-on explanation for the use of this iterative denoising approach and the validity and quality of the image enhancement filter was evaluated in a benchmarking experiment with noise footprints of a varying level of correlation and residual artefacts. They were extracted from real tomography reconstructions. We found that our denoising solutions were superior to other denoising algorithms, over a broad range of contrast-to-noise ratios on artificial piecewise constant signals.
Nyquist, Jonathan E.; Toran, Laura; Fang, Allison C.; Ryan, Robert J.; Rosenberry, Donald O.
2010-01-01
Characterization of the hyporheic zone is of critical importance for understanding stream ecology, contaminant transport, and groundwater‐surface water interaction. A salt water tracer test was used to probe the hyporheic zone of a recently re‐engineered portion of Crabby Creek, a stream located near Philadelphia, PA. The tracer solution was tracked through a 13.5 meter segment of the stream using both a network of 25 wells sampled every 5–15 minutes and time‐lapse electrical resistivity tomographs collected every 11 minutes for six hours, with additional tomographs collected every 100 minutes for an additional 16 hours. The comparison of tracer monitoring methods is of keen interest because tracer tests are one of the few techniques available for characterizing this dynamic zone, and logistically it is far easier to collect resistivity tomographs than to install and monitor a dense network of wells. Our results show that resistivity monitoring captured the essential shape of the breakthrough curve and may indicate portions of the stream where the tracer lingered in the hyporheic zone. Time‐lapse resistivity measurements, however, represent time averages over the period required to collect a tomographic data set, and spatial averages over a volume larger than captured by a well sample. Smoothing by the resistivity data inversion algorithm further blurs the resulting tomograph; consequently resistivity monitoring underestimates the degree of fine‐scale heterogeneity in the hyporheic zone.
Rapid tomographic reconstruction based on machine learning for time-resolved combustion diagnostics
NASA Astrophysics Data System (ADS)
Yu, Tao; Cai, Weiwei; Liu, Yingzheng
2018-04-01
Optical tomography has attracted surged research efforts recently due to the progress in both the imaging concepts and the sensor and laser technologies. The high spatial and temporal resolutions achievable by these methods provide unprecedented opportunity for diagnosis of complicated turbulent combustion. However, due to the high data throughput and the inefficiency of the prevailing iterative methods, the tomographic reconstructions which are typically conducted off-line are computationally formidable. In this work, we propose an efficient inversion method based on a machine learning algorithm, which can extract useful information from the previous reconstructions and build efficient neural networks to serve as a surrogate model to rapidly predict the reconstructions. Extreme learning machine is cited here as an example for demonstrative purpose simply due to its ease of implementation, fast learning speed, and good generalization performance. Extensive numerical studies were performed, and the results show that the new method can dramatically reduce the computational time compared with the classical iterative methods. This technique is expected to be an alternative to existing methods when sufficient training data are available. Although this work is discussed under the context of tomographic absorption spectroscopy, we expect it to be useful also to other high speed tomographic modalities such as volumetric laser-induced fluorescence and tomographic laser-induced incandescence which have been demonstrated for combustion diagnostics.
Rapid tomographic reconstruction based on machine learning for time-resolved combustion diagnostics.
Yu, Tao; Cai, Weiwei; Liu, Yingzheng
2018-04-01
Optical tomography has attracted surged research efforts recently due to the progress in both the imaging concepts and the sensor and laser technologies. The high spatial and temporal resolutions achievable by these methods provide unprecedented opportunity for diagnosis of complicated turbulent combustion. However, due to the high data throughput and the inefficiency of the prevailing iterative methods, the tomographic reconstructions which are typically conducted off-line are computationally formidable. In this work, we propose an efficient inversion method based on a machine learning algorithm, which can extract useful information from the previous reconstructions and build efficient neural networks to serve as a surrogate model to rapidly predict the reconstructions. Extreme learning machine is cited here as an example for demonstrative purpose simply due to its ease of implementation, fast learning speed, and good generalization performance. Extensive numerical studies were performed, and the results show that the new method can dramatically reduce the computational time compared with the classical iterative methods. This technique is expected to be an alternative to existing methods when sufficient training data are available. Although this work is discussed under the context of tomographic absorption spectroscopy, we expect it to be useful also to other high speed tomographic modalities such as volumetric laser-induced fluorescence and tomographic laser-induced incandescence which have been demonstrated for combustion diagnostics.
Field-portable lensfree tomographic microscope†
Isikman, Serhan O.; Bishara, Waheb; Sikora, Uzair; Yaglidere, Oguzhan; Yeah, John; Ozcan, Aydogan
2011-01-01
We present a field-portable lensfree tomographic microscope, which can achieve sectional imaging of a large volume (~20 mm3) on a chip with an axial resolution of <7 μm. In this compact tomographic imaging platform (weighing only ~110 grams), 24 light-emitting diodes (LEDs) that are each butt-coupled to a fibre-optic waveguide are controlled through a cost-effective micro-processor to sequentially illuminate the sample from different angles to record lensfree holograms of the sample that is placed on the top of a digital sensor array. In order to generate pixel super-resolved (SR) lensfree holograms and hence digitally improve the achievable lateral resolution, multiple sub-pixel shifted holograms are recorded at each illumination angle by electromagnetically actuating the fibre-optic waveguides using compact coils and magnets. These SR projection holograms obtained over an angular range of ~50° are rapidly reconstructed to yield projection images of the sample, which can then be back-projected to compute tomograms of the objects on the sensor-chip. The performance of this compact and light-weight lensfree tomographic microscope is validated by imaging micro-beads of different dimensions as well as a Hymenolepis nana egg, which is an infectious parasitic flatworm. Achieving a decent three-dimensional spatial resolution, this field-portable on-chip optical tomographic microscope might provide a useful toolset for telemedicine and high-throughput imaging applications in resource-poor settings. PMID:21573311
Compressive sensing reconstruction of 3D wet refractivity based on GNSS and InSAR observations
NASA Astrophysics Data System (ADS)
Heublein, Marion; Alshawaf, Fadwa; Erdnüß, Bastian; Zhu, Xiao Xiang; Hinz, Stefan
2018-06-01
In this work, the reconstruction quality of an approach for neutrospheric water vapor tomography based on Slant Wet Delays (SWDs) obtained from Global Navigation Satellite Systems (GNSS) and Interferometric Synthetic Aperture Radar (InSAR) is investigated. The novelties of this approach are (1) the use of both absolute GNSS and absolute InSAR SWDs for tomography and (2) the solution of the tomographic system by means of compressive sensing (CS). The tomographic reconstruction is performed based on (i) a synthetic SWD dataset generated using wet refractivity information from the Weather Research and Forecasting (WRF) model and (ii) a real dataset using GNSS and InSAR SWDs. Thus, the validation of the achieved results focuses (i) on a comparison of the refractivity estimates with the input WRF refractivities and (ii) on radiosonde profiles. In case of the synthetic dataset, the results show that the CS approach yields a more accurate and more precise solution than least squares (LSQ). In addition, the benefit of adding synthetic InSAR SWDs into the tomographic system is analyzed. When applying CS, adding synthetic InSAR SWDs into the tomographic system improves the solution both in magnitude and in scattering. When solving the tomographic system by means of LSQ, no clear behavior is observed. In case of the real dataset, the estimated refractivities of both methodologies show a consistent behavior although the LSQ and CS solution strategies differ.
NASA Astrophysics Data System (ADS)
Hart, V. P.; Taylor, M. J.; Doyle, T. E.; Zhao, Y.; Pautet, P.-D.; Carruth, B. L.; Rusch, D. W.; Russell, J. M.
2018-01-01
This research presents the first application of tomographic techniques for investigating gravity wave structures in polar mesospheric clouds (PMCs) imaged by the Cloud Imaging and Particle Size instrument on the NASA AIM satellite. Albedo data comprising consecutive PMC scenes were used to tomographically reconstruct a 3-D layer using the Partially Constrained Algebraic Reconstruction Technique algorithm and a previously developed "fanning" technique. For this pilot study, a large region (760 × 148 km) of the PMC layer (altitude 83 km) was sampled with a 2 km horizontal resolution, and an intensity weighted centroid technique was developed to create novel 2-D surface maps, characterizing the individual gravity waves as well as their altitude variability. Spectral analysis of seven selected wave events observed during the Northern Hemisphere 2007 PMC season exhibited dominant horizontal wavelengths of 60-90 km, consistent with previous studies. These tomographic analyses have enabled a broad range of new investigations. For example, a clear spatial anticorrelation was observed between the PMC albedo and wave-induced altitude changes, with higher-albedo structures aligning well with wave troughs, while low-intensity regions aligned with wave crests. This result appears to be consistent with current theories of PMC development in the mesopause region. This new tomographic imaging technique also provides valuable wave amplitude information enabling further mesospheric gravity wave investigations, including quantitative analysis of their hemispheric and interannual characteristics and variations.
GPS water vapour tomography: preliminary results from the ESCOMPTE field experiment
NASA Astrophysics Data System (ADS)
Champollion, C.; Masson, F.; Bouin, M.-N.; Walpersdorf, A.; Doerflinger, E.; Bock, O.; Van Baelen, J.
2005-03-01
Water vapour plays a major role in atmospheric processes but remains difficult to quantify due to its high variability in time and space and the sparse set of available measurements. The GPS has proved its capacity to measure the integrated water vapour at zenith with the same accuracy as other methods. Recent studies show that it is possible to quantify the integrated water vapour in the line of sight of the GPS satellite. These observations can be used to study the 3D heterogeneity of the troposphere using tomographic techniques. We develop three-dimensional tomographic software to model the three-dimensional distribution of the tropospheric water vapour from GPS data. First, the tomographic software is validated by simulations based on the realistic ESCOMPTE GPS network configuration. Without a priori information, the absolute value of water vapour is less resolved as opposed to relative horizontal variations. During the ESCOMPTE field experiment, a dense network of 17 dual frequency GPS receivers was operated for 2 weeks within a 20×20-km area around Marseille (southern France). The network extends from sea level to the top of the Etoile chain (˜700 m high). Optimal results have been obtained with time windows of 30-min intervals and input data evaluation every 15 min. The optimal grid for the ESCOMTE geometrical configuration has a horizontal step size of 0.05°×0.05° and 500 m vertical step size. Second, we have compared the results of real data inversions with independent observations. Three inversions have been compared to three successive radiosonde launches and shown to be consistent. A good resolution compared to the a priori information is obtained up to heights of 3000 m. A humidity spike at 4000-m altitude remains unresolved. The reason is probably that the signal is spread homogeneously over the whole network and that such a feature is not resolvable by tomographic techniques. The results of our pure GPS inversion show a correlation with meteorological phenomena. Our measurements could be related to the land-sea breeze. Undoubtedly, tomography has some interesting potential for the water vapour cycle studies at small temporal and spatial scales.
Banzato, Tommaso; Selleri, Paolo; Veladiano, Irene A; Martin, Andrea; Zanetti, Emanuele; Zotti, Alessandro
2012-05-11
Radiology and computed tomography are the most commonly available diagnostic tools for the diagnosis of pathologies affecting the head and skull in veterinary practice. Nevertheless, accurate interpretation of radiographic and CT studies requires a thorough knowledge of the gross and the cross-sectional anatomy. Despite the increasing success of reptiles as pets, only a few reports over their normal imaging features are currently available. The aim of this study is to describe the normal cadaveric, radiographic and computed tomographic features of the heads of the green iguana, tegu and bearded dragon. 6 adult green iguanas, 4 tegus, 3 bearded dragons, and, the adult cadavers of: 4 green iguana, 4 tegu, 4 bearded dragon were included in the study. 2 cadavers were dissected following a stratigraphic approach and 2 cadavers were cross-sectioned for each species. These latter specimens were stored in a freezer (-20°C) until completely frozen. Transversal sections at 5 mm intervals were obtained by means of an electric band-saw. Each section was cleaned and photographed on both sides. Radiographs of the head of each subject were obtained. Pre- and post- contrast computed tomographic studies of the head were performed on all the live animals. CT images were displayed in both bone and soft tissue windows. Individual anatomic structures were first recognised and labelled on the anatomic images and then matched on radiographs and CT images. Radiographic and CT images of the skull provided good detail of the bony structures in all species. In CT contrast medium injection enabled good detail of the soft tissues to be obtained in the iguana whereas only the eye was clearly distinguishable from the remaining soft tissues in both the tegu and the bearded dragon. The results provide an atlas of the normal anatomical and in vivo radiographic and computed tomographic features of the heads of lizards, and this may be useful in interpreting any imaging modality involving these species.
2012-01-01
Background Radiology and computed tomography are the most commonly available diagnostic tools for the diagnosis of pathologies affecting the head and skull in veterinary practice. Nevertheless, accurate interpretation of radiographic and CT studies requires a thorough knowledge of the gross and the cross-sectional anatomy. Despite the increasing success of reptiles as pets, only a few reports over their normal imaging features are currently available. The aim of this study is to describe the normal cadaveric, radiographic and computed tomographic features of the heads of the green iguana, tegu and bearded dragon. Results 6 adult green iguanas, 4 tegus, 3 bearded dragons, and, the adult cadavers of : 4 green iguana, 4 tegu, 4 bearded dragon were included in the study. 2 cadavers were dissected following a stratigraphic approach and 2 cadavers were cross-sectioned for each species. These latter specimens were stored in a freezer (−20°C) until completely frozen. Transversal sections at 5 mm intervals were obtained by means of an electric band-saw. Each section was cleaned and photographed on both sides. Radiographs of the head of each subject were obtained. Pre- and post- contrast computed tomographic studies of the head were performed on all the live animals. CT images were displayed in both bone and soft tissue windows. Individual anatomic structures were first recognised and labelled on the anatomic images and then matched on radiographs and CT images. Radiographic and CT images of the skull provided good detail of the bony structures in all species. In CT contrast medium injection enabled good detail of the soft tissues to be obtained in the iguana whereas only the eye was clearly distinguishable from the remaining soft tissues in both the tegu and the bearded dragon. Conclusions The results provide an atlas of the normal anatomical and in vivo radiographic and computed tomographic features of the heads of lizards, and this may be useful in interpreting any imaging modality involving these species. PMID:22578088
Comparison of computed tomography and complex motion tomography in the evaluation of cholesteatoma
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shaffer, K.A.
1984-08-01
High-resolution axial and coronal computed tomographic (CT) scans were compared with coronal and sagittal complex motion tomograms in patients with suspected middle ear cholesteatomas. Information on CT scans equaled or exceeded that on conventional complex motion tomograms in 16 of 17 patients, and in 11 it provided additional information. Soft-tissue resolution was superior with CT. In 14 patients who underwent surgery, CT provided information that was valuable to the surgeon. On the basis of this study, high-resolution CT is recommended as the preferred method for evaluating most patients with cholesteatomas of the temporal bone.
Radial reflection diffraction tomography
Lehman, Sean K.
2012-12-18
A wave-based tomographic imaging method and apparatus based upon one or more rotating radially outward oriented transmitting and receiving elements have been developed for non-destructive evaluation. At successive angular locations at a fixed radius, a predetermined transmitting element can launch a primary field and one or more predetermined receiving elements can collect the backscattered field in a "pitch/catch" operation. A Hilbert space inverse wave (HSIW) algorithm can construct images of the received scattered energy waves using operating modes chosen for a particular application. Applications include, improved intravascular imaging, bore hole tomography, and non-destructive evaluation (NDE) of parts having existing access holes.
Radial Reflection diffraction tomorgraphy
Lehman, Sean K
2013-11-19
A wave-based tomographic imaging method and apparatus based upon one or more rotating radially outward oriented transmitting and receiving elements have been developed for non-destructive evaluation. At successive angular locations at a fixed radius, a predetermined transmitting element can launch a primary field and one or more predetermined receiving elements can collect the backscattered field in a "pitch/catch" operation. A Hilbert space inverse wave (HSIW) algorithm can construct images of the received scattered energy waves using operating modes chosen for a particular application. Applications include, improved intravascular imaging, bore hole tomography, and non-destructive evaluation (NDE) of parts having existing access holes.
A prototype PET/SPECT/X-rays scanner dedicated for whole body small animal studies.
Rouchota, Maritina; Georgiou, Maria; Fysikopoulos, Eleftherios; Fragogeorgi, Eirini; Mikropoulos, Konstantinos; Papadimitroulas, Panagiotis; Kagadis, George; Loudos, George
2017-01-01
To present a prototype tri-modal imaging system, consisting of a single photon emission computed tomography (SPET), a positron emission tomography (PET), and a computed tomography (CT) subsystem, evaluated in planar mode. The subsystems are mounted on a rotating gantry, so as to be able to allow tomographic imaging in the future. The system, designed and constructed by our group, allows whole body mouse imaging of competent performance and is currently, to the best of our knowledge, unequaled in a national and regional level. The SPET camera is based on two Position Sensitive Photomultiplier Tubes (PSPMT), coupled to a pixilated Sodium Iodide activated with Thallium (NaI(Tl)) scintillator, having an active area of 5x10cm 2 . The dual head PET camera is also based on two pairs of PSPMT, coupled to pixelated berillium germanium oxide (BGO) scintillators, having an active area of 5x10cm 2 . The X-rays system consists of a micro focus X-rays tube and a complementary metal-oxide-semiconductor (CMOS) detector, having an active area of 12x12cm 2 . The scintigraphic mode has a spatial resolution of 1.88mm full width at half maximum (FWHM) and a sensitivity of 107.5cpm/0.037MBq at the collimator surface. The coincidence PET mode has an average spatial resolution of 3.5mm (FWHM) and a peak sensitivity of 29.9cpm/0.037MBq. The X-rays spatial resolution is 3.5lp/mm and the contrast discrimination function value is lower than 2%. A compact tri-modal system was successfully built and evaluated for planar mode operation. The system has an efficient performance, allowing accurate and informative anatomical and functional imaging, as well as semi-quantitative results. Compared to other available systems, it provides a moderate but comparable performance, at a fraction of the cost and complexity. It is fully open, scalable and its main purpose is to support groups on a national and regional level and provide an open technological platform to study different detector components and acquisition strategies.
Tomographic reflection modelling of quasi-periodic oscillations in the black hole binary H 1743-322
NASA Astrophysics Data System (ADS)
Ingram, Adam; van der Klis, Michiel; Middleton, Matthew; Altamirano, Diego; Uttley, Phil
2017-01-01
Accreting stellar mass black holes (BHs) routinely exhibit Type-C quasi-periodic oscillations (QPOs). These are often interpreted as Lense-Thirring precession of the inner accretion flow, a relativistic effect whereby the spin of the BH distorts the surrounding space-time, inducing nodal precession. The best evidence for the precession model is the recent discovery, using a long joint XMM-Newton and NuSTAR observation of H 1743-322, that the centroid energy of the iron florescence line changes systematically with QPO phase. This was interpreted as the inner flow illuminating different azimuths of the accretion disc as it precesses, giving rise to a blueshifted/redshifted iron line when the approaching/receding disc material is illuminated. Here, we develop a physical model for this interpretation, including a self-consistent reflection continuum, and fit this to the same H 1743-322 data. We use an analytic function to parametrize the asymmetric illumination pattern on the disc surface that would result from inner flow precession, and find that the data are well described if two bright patches rotate about the disc surface. This model is preferred to alternatives considering an oscillating disc ionization parameter, disc inner radius and radial emissivity profile. We find that the reflection fraction varies with QPO phase (3.5σ), adding to the now formidable body of evidence that Type-C QPOs are a geometric effect. This is the first example of tomographic QPO modelling, initiating a powerful new technique that utilizes QPOs in order to map the dynamics of accreting material close to the BH.
Hyperspectral and multispectral bioluminescence optical tomography for small animal imaging.
Chaudhari, Abhijit J; Darvas, Felix; Bading, James R; Moats, Rex A; Conti, Peter S; Smith, Desmond J; Cherry, Simon R; Leahy, Richard M
2005-12-07
For bioluminescence imaging studies in small animals, it is important to be able to accurately localize the three-dimensional (3D) distribution of the underlying bioluminescent source. The spectrum of light produced by the source that escapes the subject varies with the depth of the emission source because of the wavelength-dependence of the optical properties of tissue. Consequently, multispectral or hyperspectral data acquisition should help in the 3D localization of deep sources. In this paper, we describe a framework for fully 3D bioluminescence tomographic image acquisition and reconstruction that exploits spectral information. We describe regularized tomographic reconstruction techniques that use semi-infinite slab or FEM-based diffusion approximations of photon transport through turbid media. Singular value decomposition analysis was used for data dimensionality reduction and to illustrate the advantage of using hyperspectral rather than achromatic data. Simulation studies in an atlas-mouse geometry indicated that sub-millimeter resolution may be attainable given accurate knowledge of the optical properties of the animal. A fixed arrangement of mirrors and a single CCD camera were used for simultaneous acquisition of multispectral imaging data over most of the surface of the animal. Phantom studies conducted using this system demonstrated our ability to accurately localize deep point-like sources and show that a resolution of 1.5 to 2.2 mm for depths up to 6 mm can be achieved. We also include an in vivo study of a mouse with a brain tumour expressing firefly luciferase. Co-registration of the reconstructed 3D bioluminescent image with magnetic resonance images indicated good anatomical localization of the tumour.
Iskandrian, A S; Powers, J; Cave, V; Wasserleben, V; Cassell, D; Heo, J
1995-01-01
This study examined the ability of dynamic 123I-labeled iodophenylpentadecanoic acid (IPPA) imaging to detect myocardial viability in patients with left ventricular (LV) dysfunction caused by coronary artery disease. Serial 180-degree single-photon emission computed tomographic (SPECT) images (five sets, 8 minutes each) were obtained starting 4 minutes after injection of 2 to 6 mCi 123I at rest in 21 patients with LV dysfunction (ejection fraction [EF] 34% +/- 11%). The segmental uptake was compared with that of rest-redistribution 201Tl images (20 segments/study). The number of perfusion defects (reversible and fixed) was similar by IPPA and thallium (11 +/- 5 vs 10 +/- 5 segments/patient; difference not significant). There was agreement between IPPA and thallium for presence or absence (kappa = 0.78 +/- 0.03) and nature (reversible, mild fixed, or severe fixed) of perfusion defects (kappa = 0.54 +/- 0.04). However, there were more reversible IPPA defects than reversible thallium defects (7 +/- 4 vs 3 +/- 4 segments/patient; p = 0.001). In 14 patients the EF (by gated pool imaging) improved after coronary revascularization from 33% +/- 11% to 39% +/- 12% (p = 0.002). The number of reversible IPPA defects was greater in the seven patients who had improvement in EF than in the patients without such improvement (10 +/- 4 vs 5 +/- 4 segments/patient; p = 0.075). 123I-labeled IPPA SPECT imaging is a promising new technique for assessment of viability. Reversible defects predict recovery of LV dysfunction after coronary revascularization.
Application Of Iterative Reconstruction Techniques To Conventional Circular Tomography
NASA Astrophysics Data System (ADS)
Ghosh Roy, D. N.; Kruger, R. A.; Yih, B. C.; Del Rio, S. P.; Power, R. L.
1985-06-01
Two "point-by-point" iteration procedures, namely, Iterative Least Square Technique (ILST) and Simultaneous Iterative Reconstructive Technique (SIRT) were applied to classical circular tomographic reconstruction. The technique of tomosynthetic DSA was used in forming the tomographic images. Reconstructions of a dog's renal and neck anatomy are presented.
21 CFR 892.1740 - Tomographic x-ray system.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Tomographic x-ray system. 892.1740 Section 892.1740 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED.... This generic type of device may include signal analysis and display equipment, patient and equipment...
21 CFR 892.1740 - Tomographic x-ray system.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Tomographic x-ray system. 892.1740 Section 892.1740 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED.... This generic type of device may include signal analysis and display equipment, patient and equipment...
21 CFR 892.1740 - Tomographic x-ray system.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Tomographic x-ray system. 892.1740 Section 892.1740 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED.... This generic type of device may include signal analysis and display equipment, patient and equipment...
21 CFR 892.1740 - Tomographic x-ray system.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Tomographic x-ray system. 892.1740 Section 892.1740 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED.... This generic type of device may include signal analysis and display equipment, patient and equipment...
21 CFR 892.1740 - Tomographic x-ray system.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Tomographic x-ray system. 892.1740 Section 892.1740 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED.... This generic type of device may include signal analysis and display equipment, patient and equipment...
ECAT: A New Computerized Tomographic Imaging System for Position-Emitting Radiopharmaceuticals
DOE R&D Accomplishments Database
Phelps, M. E.; Hoffman, E. J.; Huang, S. C.; Kuhl, D. E.
1977-01-01
The ECAT was designed and developed as a complete computerized positron radionuclide imaging system capable of providing high contrast, high resolution, quantitative images in 2 dimensional and tomographic formats. Flexibility, in its various image mode options, allows it to be used for a wide variety of imaging problems.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Smith, G.S.; Dewey, S.L.; Logan, J.
1994-05-01
Our previous studies have shown that the interaction between serotonin and dopamine can be measured with C-11 raclopride and PET in the baboon brain. A series of studies was undertaken to extend dim findings to the normal human brain. PET studies were conducted in male control subjects (n=8) using the CTI 931 tomograph. Two C-11 raclopride scans were performed, prior to and 180 minutes following administration of the selective serotonin releasing agent, fenfluramine (60mg/PO). The neuroendocrine response to fenfluramine challenge is commonly used in psychiatric research as an index of serotonin activity. The C-11 raclopride data were analyzed with themore » distribution volume method. For the group of subjects, an increase was observed in the striatum to cerebellum ratio (specific to non-specific binding ratio), in excess of the test-retest variability of the ligand. Variability in response was observed across subjects. These results are consistent with our previous findings in the baboon that citalopram administration increased C-11 raclopride binding, consistent with a decrease in endogenous dopamine. In vivo microdialysis studies in freely moving rats confirmed that citalopram produces a time-dependent decrease in extracellular dopamine levels, consistent with the PET results. In vivo PET studies of the serotonin-dopamine interaction are relevant to the evaluation of etiologic and therapeutic mechanisms in schizophrenia and affective disorder.« less
Dienel, Gerald A; Behar, Kevin L; Rothman, Douglas L
2017-12-01
Ceftriaxone stimulates astrocytic uptake of the excitatory neurotransmitter glutamate, and it is used to treat glutamatergic excitotoxicity that becomes manifest during many brain diseases. Ceftriaxone-stimulated glutamate transport was reported to drive signals underlying [ 18 F]fluorodeoxyglucose-positron emission tomographic ([ 18 F]FDG-PET) metabolic images of brain glucose utilization and interpreted as supportive of the notion of lactate shuttling from astrocytes to neurons. This study draws attention to critical roles of astrocytes in the energetics and imaging of brain activity, but the results are provocative because (1) the method does not have cellular resolution or provide information about downstream pathways of glucose metabolism, (2) neuronal and astrocytic [ 18 F]FDG uptake were not separately measured, and (3) strong evidence against lactate shuttling was not discussed. Evaluation of potential metabolic responses to ceftriaxone suggests lack of astrocytic specificity and significant contributions by pre- and postsynaptic neuronal compartments. Indeed, astrocytic glycolysis may not make a strong contribution to the [ 18 F]FDG-PET signal because partial or complete oxidation of one glutamate molecule on its uptake generates enough ATP to fuel uptake of 3 to 10 more glutamate molecules, diminishing reliance on glycolysis. The influence of ceftriaxone on energetics of glutamate-glutamine cycling must be determined in astrocytes and neurons to elucidate its roles in excitotoxicity treatment.
Borri Voltattorni, Carla; Bertoldi, Mariarita; Bianconi, Silvia; Deng, Wei-ping; Wong, Kelli; Kim, InHo; Herbert, Brian; Kirk, Kenneth L
2002-07-05
We have determined the kinetic parameters for Dopa decarboxylase (DDC) of three ring-fluorinated analogs of 3,4-dihydroxyphenylalanine (Dopa). The rank order of catalytic efficiency of decarboxylation (k(cat)/K(m)) is Dopa>6-F-Dopa>2-F-Dopa>5-F-Dopa. This rank is consistent with previous in vivo and in vitro studies which indicate that, of the fluorinated analogs, 6-F-Dopa has pharmacokinetics that are most suited for positron emission tomographic (PET) evaluation of dopamine function. The effectiveness of PET as a diagnostic tool, the convenient half-life of (18)F (110 min) and the favorable pharmacokinetics of 6-[(18)F]FDOPA have combined to make this an extremely valuable reagent to study dopaminergic activity. The reactions of the related fluorinated DOPS analogs show that, while 6-F-threo-3,4-(dihydroxyphenyl)serine (DOPS) is decarboxylated at approximately the same rate as the non-fluorinated substrate, 2-F-threo-DOPS is not converted into the corresponding amine. In both cases a Pictet-Spengler condensation with the pyridoxal 5(')-phosphate (PLP) cofactor occurs to produce tetrahydroisoquinolines. Condensation of fluorinated catecholamines and catechol amino acids with endogenous aldehydes will be investigated as an approach to study possible mechanisms of L-Dopa-linked neurotoxicity. (c) 2002 Elsevier Science (USA).
Effect of whole brain radiation on local cerebral glucose utilization in the rat.
d'Avella, D; Cicciarello, R; Albiero, F; Mesiti, M; Gagliardi, M E; Russi, E; d'Aquino, A; Princi, P; d'Aquino, S
1991-04-01
We assessed, by means of the [14C]-2-deoxy-D-glucose autoradiography method, the effect of whole-brain x-radiation on local cerebral glucose utilization in the rat brain. Animals were exposed to conventional fractionation (200 +/- 4 cGy/day, 5 days/week; total dose, 4000 cGy). Metabolic experiments were made 2 to 3 weeks after completion of the radiation exposure. In comparison with control and sham-irradiated animals, cerebral metabolic activity was diffusely decreased after irradiation. Statistically significant decreases in metabolic activity were observed in 13 of 27 brain regions studied. In general, the brain areas with the highest basal metabolic rates showed the greatest percentage of decrease in glucose utilization. The concept that radiation suppresses glucose utilization before any morphological change takes place in the cell structures was the basis of this study. Metabolic alterations after irradiation may explain the syndrome of early delayed deterioration observed in humans after whole-brain radiotherapy. These studies have applications to observations made with the [18F]-fluorodeoxyglucose method in conjunction with positron emission tomographic scans in patients receiving radiation therapy for intracranial malignancies. The data reported here also have potential clinical implications for the evaluation of a risk/benefit ratio for radiotherapy in patients with benign neurosurgical diseases or children undergoing prophylactic treatment of the central nervous system.
Uncertainty loops in travel-time tomography from nonlinear wave physics.
Galetti, Erica; Curtis, Andrew; Meles, Giovanni Angelo; Baptie, Brian
2015-04-10
Estimating image uncertainty is fundamental to guiding the interpretation of geoscientific tomographic maps. We reveal novel uncertainty topologies (loops) which indicate that while the speeds of both low- and high-velocity anomalies may be well constrained, their locations tend to remain uncertain. The effect is widespread: loops dominate around a third of United Kingdom Love wave tomographic uncertainties, changing the nature of interpretation of the observed anomalies. Loops exist due to 2nd and higher order aspects of wave physics; hence, although such structures must exist in many tomographic studies in the physical sciences and medicine, they are unobservable using standard linearized methods. Higher order methods might fruitfully be adopted.
Tomographic diffractive microscopy with a wavefront sensor.
Ruan, Y; Bon, P; Mudry, E; Maire, G; Chaumet, P C; Giovannini, H; Belkebir, K; Talneau, A; Wattellier, B; Monneret, S; Sentenac, A
2012-05-15
Tomographic diffractive microscopy is a recent imaging technique that reconstructs quantitatively the three-dimensional permittivity map of a sample with a resolution better than that of conventional wide-field microscopy. Its main drawbacks lie in the complexity of the setup and in the slowness of the image recording as both the amplitude and the phase of the field scattered by the sample need to be measured for hundreds of successive illumination angles. In this Letter, we show that, using a wavefront sensor, tomographic diffractive microscopy can be implemented easily on a conventional microscope. Moreover, the number of illuminations can be dramatically decreased if a constrained reconstruction algorithm is used to recover the sample map of permittivity.
NASA Technical Reports Server (NTRS)
Yin, L. I.; Trombka, J. I.; Bielefeld, M. J.; Seltzer, S. M.
1984-01-01
The results of two computer simulations demonstrate the feasibility of using the nonoverlapping redundant array (NORA) to form three-dimensional images of objects with X-rays. Pinholes admit the X-rays to nonoverlapping points on a detector. The object is reconstructed in the analog mode by optical correlation and in the digital mode by tomographic computations. Trials were run with a stick-figure pyramid and extended objects with out-of-focus backgrounds. Substitution of spherical optical lenses for the pinholes increased the light transmission sufficiently that objects could be easily viewed in a dark room. Out-of-focus aberrations in tomographic reconstruction could be eliminated using Chang's (1976) algorithm.
Tomographic phase microscopy: principles and applications in bioimaging [Invited
Jin, Di; Zhou, Renjie; Yaqoob, Zahid; So, Peter T. C.
2017-01-01
Tomographic phase microscopy (TPM) is an emerging optical microscopic technique for bioimaging. TPM uses digital holographic measurements of complex scattered fields to reconstruct three-dimensional refractive index (RI) maps of cells with diffraction-limited resolution by solving inverse scattering problems. In this paper, we review the developments of TPM from the fundamental physics to its applications in bioimaging. We first provide a comprehensive description of the tomographic reconstruction physical models used in TPM. The RI map reconstruction algorithms and various regularization methods are discussed. Selected TPM applications for cellular imaging, particularly in hematology, are reviewed. Finally, we examine the limitations of current TPM systems, propose future solutions, and envision promising directions in biomedical research. PMID:29386746
Johnson, Jeremy J; Garwe, Tabitha; Raines, Alexander R; Thurman, Joseph B; Carter, Sandra; Bender, Jeffrey S; Albrecht, Roxie M
2013-03-01
Diagnostic laparoscopy (DL) has decreased the rate of nontherapeutic laparotomy for patients suffering from penetrating injuries. We evaluated whether DL similarly lowers the rate of nontherapeutic laparotomy for patients with blunt injuries. All patients undergoing DL over a 10-year period (ie, 2001-2010) in a single level 1 trauma center were classified by the mechanism of injury. Demographic and perioperative data were compared using the Student t and Fisher exact tests. There were 131 patients included, 22 of whom sustained blunt injuries. Patients suffering from blunt injuries were more severely injured (Injury Severity Score 18.0 vs 7.3, P = .0001). The most common indication for DL after blunt injury was a computed tomographic scan concerning for bowel injury (59.1%). The rate of nontherapeutic laparotomy for patients sustaining penetrating vs blunt injury was 1.8% and nil, respectively. DL, when coupled with computed tomographic findings, is an effective tool for the initial management of patients with blunt injuries. Copyright © 2013 Elsevier Inc. All rights reserved.
Gynecologic electrical impedance tomograph
NASA Astrophysics Data System (ADS)
Korjenevsky, A.; Cherepenin, V.; Trokhanova, O.; Tuykin, T.
2010-04-01
Electrical impedance tomography extends to the new and new areas of the medical diagnostics: lungs, breast, prostate, etc. The feedback from the doctors who use our breast EIT diagnostic system has induced us to develop the 3D electrical impedance imaging device for diagnostics of the cervix of the uterus - gynecologic impedance tomograph (GIT). The device uses the same measuring approach as the breast imaging system: 2D flat array of the electrodes arranged on the probe with handle is placed against the body. Each of the 32 electrodes of the array is connected in turn to the current source while the rest electrodes acquire the potentials on the surface. The current flows through the electrode of the array and returns through the remote electrode placed on the patient's limb. The voltages are measured relative to another remote electrode. The 3D backprojection along equipotential surfaces is used to reconstruct conductivity distribution up to approximately 1 cm in depth. Small number of electrodes enables us to implement real time imaging with a few frames per sec. rate. The device is under initial testing and evaluation of the imaging capabilities and suitability of usage.
Nguyen, Tung; Cevidanes, Lucia; Cornelis, Marie A.; Heymann, Gavin; de Paula, Leonardo K.; De Clerck, Hugo
2013-01-01
Introduction Bone-anchored maxillary protraction has been shown to be an effective treatment modality for the correction of Class III malocclusions. The purpose of this study was to evaluate 3-dimensional changes in the maxilla, the surrounding hard and soft tissues, and the circummaxillary sutures after bone-anchored maxillary protraction treatment. Methods Twenty-five consecutive skeletal Class III patients between the ages of 9 and 13 years (mean, 11.10 ± 1.1 years) were treated with Class III intermaxillary elastics and bilateral miniplates (2 in the infrazygomatic crests of the maxilla and 2 in the anterior mandible). Cone-beam computed tomographs were taken before initial loading and 1 year out. Three-dimensional models were generated from the tomographs, registered on the anterior cranial base, superimposed, and analyzed by using color maps. Results The maxilla showed a mean forward displacement of 3.7 mm, and the zygomas and the maxillary incisors came forward 3.7 and 4.3 mm, respectively. Conclusions This treatment approach produced significant orthopedic changes in the maxilla and the zygomas in growing Class III patients. PMID:22133943
Left main coronary artery stenosis: severity evaluation and implications for management.
Habibi, Susan E; Shah, Rahman; Berzingi, Chalak O; Melchior, Ryan; Sumption, Kevin F; Jovin, Ion S
2017-03-01
The significant stenosis of the left main coronary artery is associated with poor outcomes and is considered a strong indication for revascularization. However, deciding whether the stenosis is significant can sometimes be challenging, especially when the degree of stenosis is intermediate, and can necessitate additional tests and imaging modalities. Areas covered: We did a literature search using keywords like 'left main', 'imaging', 'intravascular ultrasound', 'fractional flow reserve', 'computed tomographic angiography' and 'magnetic resonance imaging'. The most commonly used methods for better characterizing intermediate left main coronary stenoses are intravascular ultrasound and fractional flow reserve, while optical coherence tomography is the newer technique that provides better images, but for which not as much data is available. The noninvasive techniques are coronary computed tomographic angiography and, to a lesser degree, coronary magnetic resonance imaging. Expert commentary: Accurately determining the severity of left main coronary stenosis can mean the difference between a major intervention and conservative therapy. The reviewed newer imaging modalities give us greater confidence that patients with left main stenosis are assigned to the right treatment modality.
Methods to mitigate data truncation artifacts in multi-contrast tomosynthesis image reconstructions
NASA Astrophysics Data System (ADS)
Garrett, John; Ge, Yongshuai; Li, Ke; Chen, Guang-Hong
2015-03-01
Differential phase contrast imaging is a promising new image modality that utilizes the refraction rather than the absorption of x-rays to image an object. A Talbot-Lau interferometer may be used to permit differential phase contrast imaging with a conventional medical x-ray source and detector. However, the current size of the gratings fabricated for these interferometers are often relatively small. As a result, data truncation image artifacts are often observed in a tomographic acquisition and reconstruction. When data are truncated in x-ray absorption imaging, the methods have been introduced to mitigate the truncation artifacts. However, the same strategy to mitigate absorption truncation artifacts may not be appropriate for differential phase contrast or dark field tomographic imaging. In this work, several new methods to mitigate data truncation artifacts in a multi-contrast imaging system have been proposed and evaluated for tomosynthesis data acquisitions. The proposed methods were validated using experimental data acquired for a bovine udder as well as several cadaver breast specimens using a benchtop system at our facility.
Mittleman, D M; Hunsche, S; Boivin, L; Nuss, M C
1997-06-15
We demonstrate tomographic T-ray imaging, using the timing information present in terahertz (THz) pulses in a reflection geometry. THz pulses are reflected from refractive-index discontinuities inside an object, and the time delays of these pulses are used to determine the positions of the discontinuities along the propagation direction. In this fashion a tomographic image can be constructed.
Computed tomographic findings of cerebral fat embolism following multiple bone fractures.
Law, Huong Ling; Wong, Siong Lung; Tan, Suzet
2013-02-01
Fat embolism to the lungs and brain is an uncommon complication following fractures. Few reports with descriptions of computed tomographic (CT) findings of emboli to the brain or cerebral fat embolism are available. We report a case of cerebral fat embolism following multiple skeletal fractures and present its CT findings here.
Quantum-tomographic cryptography with a semiconductor single-photon source
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kaszlikowski, D.; Yang, L.J.; Yong, L.S.
2005-09-15
We analyze the security of so-called quantum-tomographic cryptography with the source producing entangled photons via an experimental scheme proposed by Fattal et al. [Phys. Rev. Lett. 92, 37903 (2004)]. We determine the range of the experimental parameters for which the protocol is secure against the most general incoherent attacks.
Current developments in clinical multiphoton tomography
NASA Astrophysics Data System (ADS)
König, Karsten; Weinigel, Martin; Breunig, Hans Georg; Gregory, Axel; Fischer, Peter; Kellner-Höfer, Marcel; Bückle, Rainer
2010-02-01
Two-photon microscopy has been introduced in 1990 [1]. 13 years later, CE-marked clinical multiphoton systems for 3D imaging of human skin with subcellular resolution have been launched by the JenLab company with the tomograph DermaInspectTM. In 2010, the second generation of clinical multiphoton tomographs was introduced. The novel mobile multiphoton tomograph MPTflexTM, equipped with a flexible articulated optical arm, provides an increased flexibility and accessibility especially for clinical and cosmetical examinations. The multiphoton excitation of fluorescent biomolecules like NAD(P)H, flavins, porphyrins, elastin, and melanin as well as the second harmonic generation of collagen is induced by picojoule femtosecond laser pulses from an tunable turn-key near infrared laser system. The ability for rapid highquality image acquisition, the user-friendly operation of the system, and the compact and flexible design qualifies this system to be used for melanoma detection, diagnostics of dermatological disorders, cosmetic research, and skin aging measurements as well as in situ drug monitoring and animal research. So far, more than 1,000 patients and volunteers have been investigated with the multiphoton tomographs in Europe, Asia, and Australia.
Tomography and the Herglotz-Wiechert inverse formulation
NASA Astrophysics Data System (ADS)
Nowack, Robert L.
1990-04-01
In this paper, linearized tomography and the Herglotz-Wiechert inverse formulation are compared. Tomographic inversions for 2-D or 3-D velocity structure use line integrals along rays and can be written in terms of Radon transforms. For radially concentric structures, Radon transforms are shown to reduce to Abel transforms. Therefore, for straight ray paths, the Abel transform of travel-time is a tomographic algorithm specialized to a one-dimensional radially concentric medium. The Herglotz-Wiechert formulation uses seismic travel-time data to invert for one-dimensional earth structure and is derived using exact ray trajectories by applying an Abel transform. This is of historical interest since it would imply that a specialized tomographic-like algorithm has been used in seismology since the early part of the century (see Herglotz, 1907; Wiechert, 1910). Numerical examples are performed comparing the Herglotz-Wiechert algorithm and linearized tomography along straight rays. Since the Herglotz-Wiechert algorithm is applicable under specific conditions, (the absence of low velocity zones) to non-straight ray paths, the association with tomography may prove to be useful in assessing the uniqueness of tomographic results generalized to curved ray geometries.
A detailed comparison of single-camera light-field PIV and tomographic PIV
NASA Astrophysics Data System (ADS)
Shi, Shengxian; Ding, Junfei; Atkinson, Callum; Soria, Julio; New, T. H.
2018-03-01
This paper conducts a comprehensive study between the single-camera light-field particle image velocimetry (LF-PIV) and the multi-camera tomographic particle image velocimetry (Tomo-PIV). Simulation studies were first performed using synthetic light-field and tomographic particle images, which extensively examine the difference between these two techniques by varying key parameters such as pixel to microlens ratio (PMR), light-field camera Tomo-camera pixel ratio (LTPR), particle seeding density and tomographic camera number. Simulation results indicate that the single LF-PIV can achieve accuracy consistent with that of multi-camera Tomo-PIV, but requires the use of overall greater number of pixels. Experimental studies were then conducted by simultaneously measuring low-speed jet flow with single-camera LF-PIV and four-camera Tomo-PIV systems. Experiments confirm that given a sufficiently high pixel resolution, a single-camera LF-PIV system can indeed deliver volumetric velocity field measurements for an equivalent field of view with a spatial resolution commensurate with those of multi-camera Tomo-PIV system, enabling accurate 3D measurements in applications where optical access is limited.
Diaz, Alejandro A; Estépar, Raul San José; Washko, George R
2016-01-01
Computed tomographic measures of central airway morphology have been used in clinical, epidemiologic, and genetic investigation as an inference of the presence and severity of small-airway disease in smokers. Although several association studies have brought us to believe that these computed tomographic measures reflect airway remodeling, a careful review of such data and more recent evidence may reveal underappreciated complexity to these measures and limitations that prompt us to question that belief. This Perspective offers a review of seminal papers and alternative explanations of their data in the light of more recent evidence. The relationships between airway morphology and lung function are observed in subjects who never smoked, implying that native airway structure indeed contributes to lung function; computed tomographic measures of central airways such as wall area, lumen area, and total bronchial area are smaller in smokers with chronic obstructive pulmonary disease versus those without chronic obstructive pulmonary disease; and the airways are smaller as disease severity increases. The observations suggest that (1) native airway morphology likely contributes to the relationships between computed tomographic measures of airways and lung function; and (2) the presence of smaller airways in those with chronic obstructive pulmonary disease versus those without chronic obstructive pulmonary disease as well as their decrease with disease severity suggests that smokers with chronic obstructive pulmonary disease may simply have smaller airways to begin with, which put them at greater risk for the development of smoking-related disease.
Hierarchical multimodal tomographic x-ray imaging at a superbend
NASA Astrophysics Data System (ADS)
Stampanoni, M.; Marone, F.; Mikuljan, G.; Jefimovs, K.; Trtik, P.; Vila-Comamala, J.; David, C.; Abela, R.
2008-08-01
Over the last decade, synchrotron-based X-ray tomographic microscopy has established itself as a fundamental tool for non-invasive, quantitative investigations of a broad variety of samples, with application ranging from space research and materials science to biology and medicine. Thanks to the brilliance of modern third generation sources, voxel sizes in the micrometer range are routinely achieved by the major X-ray microtomography devices around the world, while the isotropic 100 nm barrier is reached and trespassed only by few instruments. The beamline for TOmographic Microscopy and Coherent rAdiology experiments (TOMCAT) of the Swiss Light Source at the Paul Scherrer Institut, operates a multimodal endstation which offers tomographic capabilities in the micrometer range in absorption contrast - of course - as well as phase contrast imaging. Recently, the beamline has been equipped with a full field, hard X-rays microscope with a theoretical pixel size down to 30 nm and a field of view of 50 microns. The nanoscope performs well at X-ray energies between 8 and 12 keV, selected from the white beam of a 2.9 T superbend by a [Ru/C]100 fixed exit multilayer monochromator. In this work we illustrate the experimental setup dedicated to the nanoscope, in particular the ad-hoc designed X-ray optics needed to produce a homogeneous, square illumination of the sample imaging plane as well as the magnifying zone plate. Tomographic reconstructions at 60 nm voxel size will be shown and discussed.
Field-portable lensfree tomographic microscope.
Isikman, Serhan O; Bishara, Waheb; Sikora, Uzair; Yaglidere, Oguzhan; Yeah, John; Ozcan, Aydogan
2011-07-07
We present a field-portable lensfree tomographic microscope, which can achieve sectional imaging of a large volume (∼20 mm(3)) on a chip with an axial resolution of <7 μm. In this compact tomographic imaging platform (weighing only ∼110 grams), 24 light-emitting diodes (LEDs) that are each butt-coupled to a fibre-optic waveguide are controlled through a cost-effective micro-processor to sequentially illuminate the sample from different angles to record lensfree holograms of the sample that is placed on the top of a digital sensor array. In order to generate pixel super-resolved (SR) lensfree holograms and hence digitally improve the achievable lateral resolution, multiple sub-pixel shifted holograms are recorded at each illumination angle by electromagnetically actuating the fibre-optic waveguides using compact coils and magnets. These SR projection holograms obtained over an angular range of ±50° are rapidly reconstructed to yield projection images of the sample, which can then be back-projected to compute tomograms of the objects on the sensor-chip. The performance of this compact and light-weight lensfree tomographic microscope is validated by imaging micro-beads of different dimensions as well as a Hymenolepis nana egg, which is an infectious parasitic flatworm. Achieving a decent three-dimensional spatial resolution, this field-portable on-chip optical tomographic microscope might provide a useful toolset for telemedicine and high-throughput imaging applications in resource-poor settings. This journal is © The Royal Society of Chemistry 2011
Relative arrival-time upper-mantle tomography and the elusive background mean
NASA Astrophysics Data System (ADS)
Bastow, Ian D.
2012-08-01
The interpretation of seismic tomographic images of upper-mantle seismic wave speed structure is often a matter of considerable debate because the observations can usually be explained by a range of hypotheses, including variable temperature, composition, anisotropy, and the presence of partial melt. An additional problem, often overlooked in tomographic studies using relative as opposed to absolute arrival-times, is the issue of the resulting velocity model's zero mean. In shield areas, for example, relative arrival-time analysis strips off a background mean velocity structure that is markedly fast compared to the global average. Conversely, in active areas, the background mean is often markedly slow compared to the global average. Appreciation of this issue is vital when interpreting seismic tomographic images: 'high' and 'low' velocity anomalies should not necessarily be interpreted, respectively, as 'fast' and 'slow' compared to 'normal mantle'. This issue has been discussed in the seismological literature in detail over the years, yet subsequent tomography studies have still fallen into the trap of mis-interpreting their velocity models. I highlight here some recent examples of this and provide a simple strategy to address the problem using constraints from a recent global tomographic model, and insights from catalogues of absolute traveltime anomalies. Consultation of such absolute measures of seismic wave speed should be routine during regional tomographic studies, if only for the benefit of the broader Earth Science community, who readily follow the red = hot and slow, blue = cold and fast rule of thumb when interpreting the images for themselves.
Downscaling Smooth Tomographic Models: Separating Intrinsic and Apparent Anisotropy
NASA Astrophysics Data System (ADS)
Bodin, Thomas; Capdeville, Yann; Romanowicz, Barbara
2016-04-01
In recent years, a number of tomographic models based on full waveform inversion have been published. Due to computational constraints, the fitted waveforms are low pass filtered, which results in an inability to map features smaller than half the shortest wavelength. However, these tomographic images are not a simple spatial average of the true model, but rather an effective, apparent, or equivalent model that provides a similar 'long-wave' data fit. For example, it can be shown that a series of horizontal isotropic layers will be seen by a 'long wave' as a smooth anisotropic medium. In this way, the observed anisotropy in tomographic models is a combination of intrinsic anisotropy produced by lattice-preferred orientation (LPO) of minerals, and apparent anisotropy resulting from the incapacity of mapping discontinuities. Interpretations of observed anisotropy (e.g. in terms of mantle flow) requires therefore the separation of its intrinsic and apparent components. The "up-scaling" relations that link elastic properties of a rapidly varying medium to elastic properties of the effective medium as seen by long waves are strongly non-linear and their inverse highly non-unique. That is, a smooth homogenized effective model is equivalent to a large number of models with discontinuities. In the 1D case, Capdeville et al (GJI, 2013) recently showed that a tomographic model which results from the inversion of low pass filtered waveforms is an homogenized model, i.e. the same as the model computed by upscaling the true model. Here we propose a stochastic method to sample the ensemble of layered models equivalent to a given tomographic profile. We use a transdimensional formulation where the number of layers is variable. Furthermore, each layer may be either isotropic (1 parameter) or intrinsically anisotropic (2 parameters). The parsimonious character of the Bayesian inversion gives preference to models with the least number of parameters (i.e. least number of layers, and maximum number of isotropic layers). The non-uniqueness of the problem can be addressed by adding high frequency data such as receiver functions, able to map first order discontinuities. We show with synthetic tests that this method enables us to distinguish between intrinsic and apparent anisotropy in tomographic models, as layers with intrinsic anisotropy are only present when required by the data. A real data example is presented based on the latest global model produced at Berkeley.
Lane, John I; Witte, Robert J; Driscoll, Colin L W; Shallop, Jon K; Beatty, Charles W; Primak, Andrew N
2007-08-01
To use the improved resolution available with 64-slice multidetector computed tomography (MDCT) in vivo to localize the cochlear implant electrode array within the basal turn. Sixty-four-slice MDCT examinations of the temporal bones were retrospectively reviewed in 17 patients. Twenty-three implants were evaluated. Tertiary referral facility. All patients with previous cochlear implantation evaluated at our center between January 2004 and March 2006 were offered a computed tomographic examination as part of the study. In addition, preoperative computed tomographic examinations in patients being evaluated for a second bilateral device were included. Sixty-four-slice MDCT examination of the temporal bones. Localization of the electrode array within the basal turn from multiplanar reconstructions of the cochlea. Twenty-three implants were imaged in 17 patients. We were able to localize the electrode array within the scala tympani within the basal turn in 10 implants. In 3 implants, the electrode array was localized to the scala vestibuli. Migration of the electrode array from scala tympani to scala vestibuli was observed in three implants. Of the 7 implants in which localization of the electrode array was indeterminate, all had disease entities that obscured the definition of the normal cochlear anatomy. Sixty-four-slice MDCT with multiplanar reconstructions of the postoperative cochlea after cochlear implantation allows for accurate localization of the electrode array within the basal turn where normal cochlear anatomy is not obscured by the underlying disease process. Correlating the position of the electrode in the basal turn with surgical technique and implant design could be helpful in improving outcomes.
Martin, Raul
2018-01-01
Current corneal assessment technologies make the process of corneal evaluation extremely fast and simple and several devices and technologies allow to explore and to manage patients. The purpose of this special issue is to present and also to update in the evaluation of cornea and ocular surface and this second part, reviews a description of the corneal topography and tomography techniques, providing updated information of the clinical recommendations of these techniques in eye care practice. Placido-based topographers started an exciting anterior corneal surface analysis that allows the development of current corneal tomographers that provide a full three-dimensional reconstruction of the cornea including elevation, curvature, and pachymetry data of anterior and posterior corneal surfaces. Although, there is not an accepted reference standard technology for corneal topography description and it is not possible to determine which device produces the most accurate topographic measurements, placido-based topographers are a valuable technology to be used in primary eye care and corneal tomograhers expanding the possibilities to explore cornea and anterior eye facilitating diagnosis and follow-up in several situations, raising patient follow-up, and improving the knowledge regarding to the corneal anatomy. Main disadvantages of placido-based topographers include the absence of information about the posterior corneal surface and limited corneal surface coverage without data from the para-central and/or peripheral corneal surface. However, corneal tomographers show repeatable anterior and posterior corneal surfaces measurements, providing full corneal thickness data improving cornea, and anterior surface assessment. However, differences between devices suggest that they are not interchangeable in clinical practice. PMID:29480244
Martin, Raul
2018-03-01
Current corneal assessment technologies make the process of corneal evaluation extremely fast and simple and several devices and technologies allow to explore and to manage patients. The purpose of this special issue is to present and also to update in the evaluation of cornea and ocular surface and this second part, reviews a description of the corneal topography and tomography techniques, providing updated information of the clinical recommendations of these techniques in eye care practice. Placido-based topographers started an exciting anterior corneal surface analysis that allows the development of current corneal tomographers that provide a full three-dimensional reconstruction of the cornea including elevation, curvature, and pachymetry data of anterior and posterior corneal surfaces. Although, there is not an accepted reference standard technology for corneal topography description and it is not possible to determine which device produces the most accurate topographic measurements, placido-based topographers are a valuable technology to be used in primary eye care and corneal tomograhers expanding the possibilities to explore cornea and anterior eye facilitating diagnosis and follow-up in several situations, raising patient follow-up, and improving the knowledge regarding to the corneal anatomy. Main disadvantages of placido-based topographers include the absence of information about the posterior corneal surface and limited corneal surface coverage without data from the para-central and/or peripheral corneal surface. However, corneal tomographers show repeatable anterior and posterior corneal surfaces measurements, providing full corneal thickness data improving cornea, and anterior surface assessment. However, differences between devices suggest that they are not interchangeable in clinical practice.
Xu, Rende; Li, Chenguang; Qian, Juying; Ge, Junbo
2015-11-01
Invasive fractional flow reserve (FFR) is the gold standard for the determination of physiologic stenosis severity and the need for revascularization. FFR computed from standard acquired coronary computed tomographic angiography datasets (FFRCT) is an emerging technology which allows calculation of FFR using resting image data from coronary computed tomographic angiography (CCTA). However, the diagnostic accuracy of FFRCT in the evaluation of lesion-specific myocardial ischemia remains to be confirmed, especially in patients with intermediate coronary stenosis. We performed an integrated analysis of data from 3 prospective, international, and multicenter trials, which assessed the diagnostic performance of FFRCT using invasive FFR as a reference standard. Three studies evaluating 609 patients and 1050 vessels were included. The total calculated sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of FFRCT were 82.8%, 77.7%, 60.8%, 91.6%, and 79.2%, respectively, for the per-vessel analysis, and 89.4%, 70.5%, 69.7%, 89.7%, and 78.7%, respectively, for the per-patient analysis. Compared with CCTA alone, FFRCT demonstrated significantly improved accuracy (P < 0.001) in detecting lesion-specific ischemia. In patients with intermediate coronary stenosis, FFRCT remained both highly sensitive and specific with respect to the diagnosis of ischemia. In conclusion, FFRCT appears to be a reliable noninvasive alternative to invasive FFR, as it demonstrates high accuracy in the determination of anatomy and lesion-specific ischemia, which justifies the performance of additional randomized controlled trials to evaluate both the clinical benefits and the cost-effectiveness of FFRCT-guided coronary revascularization.
Rostami, Abdolrazagh; Geissbühler, Urs; Schellenberger, Frank; Zanolari, Patrik
2014-01-06
Tooth root problems and periodontal diseases are common in South American camelids (SAC). The objective was to evaluate and optimize the imaging technique for dental radiography in SAC and to describe the radiographic and computed tomographic (CT) anatomy of normal teeth at different ages. In this study, the heads of 20 healthy SAC slaughtered for meat production or euthanized for reasons not related to dental problems included 7 female and 10 male llamas and 3 male alpacas. Using a standardized protocol, radiographs and CT scans of the 20 specimen were performed. The most useful radiographic projections for mandibular and maxillary cheek teeth evaluation turned out to be lateral30°ventral-laterodorsal and lateral30°dorsal-lateroventral with slight separation of the dental arcades respectively. Digital radiographic and CT appearance of the mandibular and maxillary teeth were described from the beginning of mineralization till maturity. In addition the normal range of the CT radio density of different cheek teeth and different dental tissues were measured. Hounsfield units of different dental tissues of SAC turned out to be similar to equids. Deviation, shortening and partial destruction of the distal tooth root of mandibular 09's and 10's and of maxillary 09's was observed and the existence of a common pulp chamber in younger teeth was revealed. The present study provides information about the dental imaging morphology in clinically healthy SAC. This basic information provides fundamental knowledge for evaluating images and planning treatments in clinically affected animals.
2014-01-01
Background Tooth root problems and periodontal diseases are common in South American camelids (SAC). The objective was to evaluate and optimize the imaging technique for dental radiography in SAC and to describe the radiographic and computed tomographic (CT) anatomy of normal teeth at different ages. In this study, the heads of 20 healthy SAC slaughtered for meat production or euthanized for reasons not related to dental problems included 7 female and 10 male llamas and 3 male alpacas. Using a standardized protocol, radiographs and CT scans of the 20 specimen were performed. Results The most useful radiographic projections for mandibular and maxillary cheek teeth evaluation turned out to be lateral30°ventral - laterodorsal and lateral30°dorsal - lateroventral with slight separation of the dental arcades respectively. Digital radiographic and CT appearance of the mandibular and maxillary teeth were described from the beginning of mineralization till maturity. In addition the normal range of the CT radio density of different cheek teeth and different dental tissues were measured. Hounsfield units of different dental tissues of SAC turned out to be similar to equids. Deviation, shortening and partial destruction of the distal tooth root of mandibular 09′s and 10′s and of maxillary 09′s was observed and the existence of a common pulp chamber in younger teeth was revealed. Conclusions The present study provides information about the dental imaging morphology in clinically healthy SAC. This basic information provides fundamental knowledge for evaluating images and planning treatments in clinically affected animals. PMID:24393365
Battaglia, Salvatore; Maiolo, Vincenzo; Savastio, Gabriella; Zompatori, Maurizio; Contedini, Federico; Antoniazzi, Elisa; Cipriani, Riccardo; Marchetti, Claudio; Tarsitano, Achille
2017-10-01
Mandibular reconstruction performed after virtual planning has become more common during recent years. The gold standard for extensive mandibular reconstruction is of course a fibular free flap. In designing an osteomyocutaneous fibula flap, poor planning, aberrant anatomy and/or inadequate perforator vessels are the most frequent causes of complications and may force the surgeon to modify the flap design, explore the contralateral leg or harvest an additional microvascular flap. The goal of our study was to pre-operatively evaluate the vascular anatomy of the fibula and localize the cutaneous perforator vessels, so to create the fibular cutting guide based on the position of the cutaneous perforator and safely harvest the reconstructive flap. Twenty consecutive patients who were candidates for mandibular reconstruction using a fibular microvascular free flap were enrolled in this study between January 2016 and August 2016. The patients were preoperatively assessed with a Computed Tomographic scan of head and neck and with a Computed Tomographic Angiography (CTA) scan of the lower limbs to evaluate the vascular anatomy of the fibula. Virtual planning was carried out for all patients. The fibular cutting guide was based on the position of the perforator cutaneous vessels, which were used to harvest the cutaneous part of the flap. Preoperative CT measurements were performed in order to identify the cutaneous perforators on the patients' skin. Intraoperative checking was performed to evaluate the accuracy of the perforators' position and the reproducibility of the virtual planning. In 5 patients out of 20 (25%), anatomical anomalies were discovered, without clinical evidence. The perforator vessels were localized in all patients. The average difference between the CTA and the intraoperative perforator localization was 1 mm (range 0-2 mm). Fibular cutting guide was positioned and fitted the anatomy of the patients in all treated patients. This allowed us to perform the planned segmentation of the fibula, obtaining the correct number of segments. In all cases, flap insetting was carried out and skin paddle was positioned as preoperatively planned. Neither donor site complications nor flap complications occurred. Preoperative evaluation of the legs using CTA, in patients who undergo an osteomyocutaneous fibular free flap for mandibular reconstruction, is a valuable approach to reduce altered-anatomy related complications and to improve the accuracy and outcomes of the reconstruction, especially in reconstructions of complex defects. In these cases, a soft tissue-based cutting guide can be planned based on the perforator vessels of the skin paddle, minimizing the harvesting risks of vascular lesions. Further studies and longer follow-ups are needed to evaluate the long-term outcomes and advantages of this procedure. Copyright © 2017 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
System for plotting subsoil structure and method therefor
NASA Technical Reports Server (NTRS)
Narasimhan, K. Y.; Nathan, R.; Parthasarathy, S. P. (Inventor)
1980-01-01
Data for use in producing a tomograph of subsoil structure between boreholes is derived by pacing spaced geophones in one borehole, on the Earth surface if desired, and by producing a sequence of shots at spaced apart locations in the other borehole. The signals, detected by each of the geophones from the various shots, are processed either on a time of arrival basis, or on the basis of signal amplitude, to provide information of the characteristics of a large number of incremental areas between the boreholes. Such information is useable to produce a tomograph of the subsoil structure between the boreholes. By processing signals of relatively high frequencies, e.g., up to 100 Hz, and by closely spacing the geophones, a high resolution tomograph can be produced.
Robust statistical reconstruction for charged particle tomography
Schultz, Larry Joe; Klimenko, Alexei Vasilievich; Fraser, Andrew Mcleod; Morris, Christopher; Orum, John Christopher; Borozdin, Konstantin N; Sossong, Michael James; Hengartner, Nicolas W
2013-10-08
Systems and methods for charged particle detection including statistical reconstruction of object volume scattering density profiles from charged particle tomographic data to determine the probability distribution of charged particle scattering using a statistical multiple scattering model and determine a substantially maximum likelihood estimate of object volume scattering density using expectation maximization (ML/EM) algorithm to reconstruct the object volume scattering density. The presence of and/or type of object occupying the volume of interest can be identified from the reconstructed volume scattering density profile. The charged particle tomographic data can be cosmic ray muon tomographic data from a muon tracker for scanning packages, containers, vehicles or cargo. The method can be implemented using a computer program which is executable on a computer.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Groth, M; Ellis, R; Brooks, N
A video camera system is described that measures the spatial distribution of visible line emission emitted from the main scrape-off layer (SOL) of plasmas in the DIII-D tokamak. A wide-angle lens installed on an equatorial port and an in-vessel mirror which intercepts part of the lens view provide simultaneous tangential views of the SOL on the low-field and high-field sides of the plasma's equatorial plane. Tomographic reconstruction techniques are used to calculate the 2-D poloidal profiles from the raw data, and 1-D poloidal profiles simulating chordal views of other optical diagnostics from the 2-D profiles. The 2-D profiles can bemore » compared with SOL plasma simulations; the 1-D profiles with measurements from spectroscopic diagnostics. Sample results are presented which elucidate carbon transport in plasmas with toroidally uniform injection of methane and argon transport in disruption mitigation experiments with massive gas jet injection.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Seo, Dongcheol; Peterson, B. J.; Lee, Seung Hun
The resistive bolometers have been successfully installed in the midplane of L-port in Korea Superconducting Tokamak Advanced Research (KSTAR) device. The spatial and temporal resolutions, 4.5 cm and {approx}1 kHz, respectively, enable us to measure the radial profile of the total radiated power from magnetically confined plasma at a high temperature through radiation and neutral particles. The radiated power was measured at all shots. Even at low plasma current, the bolometer signal was detectable. The electron cyclotron resonance heating (ECH) has been used in tokamak for ECH assisted start-up and plasma control by local heating and current drive. The detectorsmore » of resistive bolometer, near the antenna of ECH, are affected by electron cyclotron wave. The tomographic reconstruction, using the Phillips-Tikhonov regularization method, will be carried out for a major radial profile of the radiation emissivity of the circular cross-section plasma.« less
In vivo biodistribution of ginkgolide B, a constituent of Ginkgo biloba, visualized by MicroPET.
Suehiro, Makiko; Simpson, Norman R; Underwood, Mark D; Castrillon, John; Nakanishi, Koji; van Heertum, Ronald
2005-07-01
The in vivo dynamic behavior of ginkgolide B (GB), a terpene lactone constituent of the Ginkgo biloba extracts, in the living animal was visualized by positron emission tomographic (PET) imaging using a GB analogue labeled with the positron emitter (18)F. The in vivo imaging studies, combined with ex vivo dissection experiments, reveal that GB exists in 2 forms in the body: the original GB with its lactone rings closed and a second form with one of the rings open. The original GB in plasma is taken up rapidly by various organs including the liver, the intestine and possibly the stomach. Consequently, in plasma, the proportion of the ionized form of GB increases dramatically with time. Thereafter the ratio between the 2 forms appears to shift slowly towards equilibrium. The results suggest that more attention needs to be focused on in vivo dynamics between the 2 forms of GB.
Caliyurt, Okan; Vardar, Erdal; Tuglu, Cengiz
2004-01-01
We report a case of Cotard's syndrome associated with psychotic symptoms. A 27-year-old man was admitted to hospital with the diagnosis of schizophreniform disorder. His presenting symptoms, which had started 1 month before hospital admission, were somatic delusions of gastrointestinal and cardiovascular malfunction and the absence of a stomach, which resulted in a decrease in weight from 75 kg to 63 kg in 1 month. Cranial computed tomographic images showed dilatation of the lateral and third ventricles, whereas magnetic resonance imaging revealed central atrophy and lateral ventricle dilatation. Single- photon emission computed tomography demonstrated left temporal, left frontal and left parietal hypoperfusion. The patient did not respond to antipsychotic therapies, but he was successfully treated with electroconvulsive therapy. This report emphasizes that Cotard's syndrome may be accompanied by lesions of the left hemisphere and that electroconvulsive therapy could be the first-line therapy in such patients with psychotic disorder. PMID:15069468
Arenberg, Douglas
2011-02-01
This review focuses on aspects of bronchioloalveolar carcinoma (BAC) in which it differs importantly from other forms of non-small-cell lung cancer. BAC is a form of adenocarcinoma with unique clinical, radiological, and epidemiological features. With the notable exception of a lower likelihood of a positive positron-emission tomographic (PET) scan in BAC, staging, diagnosis, and treatment are largely the same as for other histological subtypes of lung cancer. However, additional treatment options exist that are equivalent, if not more effective, for many patients with BAC. The diagnosis of BAC should be reserved for those tumors meeting the 1999/2004 criteria set forth by the World Health Organization. Revised nomenclature proposed by an expert consensus panel may change how this disease is viewed. Additional clinical trials are needed on patients with BAC, employing strict definitions and enrollment criteria to allow the results to be applied to appropriate patient populations. © Thieme Medical Publishers.
In vivo fluorescence lifetime tomography of a FRET probe expressed in mouse
McGinty, James; Stuckey, Daniel W.; Soloviev, Vadim Y.; Laine, Romain; Wylezinska-Arridge, Marzena; Wells, Dominic J.; Arridge, Simon R.; French, Paul M. W.; Hajnal, Joseph V.; Sardini, Alessandro
2011-01-01
Förster resonance energy transfer (FRET) is a powerful biological tool for reading out cell signaling processes. In vivo use of FRET is challenging because of the scattering properties of bulk tissue. By combining diffuse fluorescence tomography with fluorescence lifetime imaging (FLIM), implemented using wide-field time-gated detection of fluorescence excited by ultrashort laser pulses in a tomographic imaging system and applying inverse scattering algorithms, we can reconstruct the three dimensional spatial localization of fluorescence quantum efficiency and lifetime. We demonstrate in vivo spatial mapping of FRET between genetically expressed fluorescent proteins in live mice read out using FLIM. Following transfection by electroporation, mouse hind leg muscles were imaged in vivo and the emission of free donor (eGFP) in the presence of free acceptor (mCherry) could be clearly distinguished from the fluorescence of the donor when directly linked to the acceptor in a tandem (eGFP-mCherry) FRET construct. PMID:21750768
Lockwood, Alan H; Weissenborn, Karin; Bokemeyer, Martin; Tietge, U; Burchert, Wolfgang
2002-03-01
Many cirrhotics have abnormal neuropsychological test scores. To define the anatomical-physiological basis for encephalopathy in nonalcoholic cirrhotics, we performed resting-state fluorodeoxyglucose positron emission tomographic scans and administered a neuropsychological test battery to 18 patients and 10 controls. Statistical parametric mapping correlated changes in regional glucose metabolism with performance on the individual tests and a composite battery score. In patients without overt encephalopathy, poor performance correlated with reductions in metabolism in the anterior cingulate. In all patients, poor performance on the battery was positively correlated (p < 0.001) with glucose metabolism in bifrontal and biparietal regions of the cerebral cortex and negatively correlated with metabolism in hippocampal, lingual, and fusiform gyri and the posterior putamen. Similar patterns of abnormal metabolism were found when comparing the patients to 10 controls. Metabolic abnormalities in the anterior attention system and association cortices mediating executive and integrative function form the pathophysiological basis for mild hepatic encephalopathy.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kuhl, D.E.; Phelps, M.E.; Engel, J. Jr.
1980-01-01
The ECAT Positron Tomograph was used to scan normal control subjects, stroke patients at various times during recovery, and patients with partial epilepsy during EEG monitoring. /sup 18/F-fluorodeoxyglucose (/sup 18/FDG) and /sup 13/N-Ammonia (/sup 13/NH/sub 3/) were used as indicators of abnormalities in local cerebral glucose utilization (LCMR/sub glc/) and relative perfusion, respectively. Hypometabolism, due to deactivation or minimal damage, was demonstrated with the /sup 18/FDG scan in deep structures and broad zones of cerebral cortex which appeared normal on x-ray CT (XCT) and /sup 99m/Tc pertechnetate scans. In patients with partial epilepsy, who had unilateral or focal electrical abnormalities,more » interictal /sup 18/FDG scan patterns clearly showed localized regions of decreased (20 to 50%) LCMR/sub glc/, which correlated anatomically with the eventual EEG localization.« less
Coronal Polarization of Pseudostreamers and the Solar Polar Field Reversal
NASA Technical Reports Server (NTRS)
Rachmeler, L. A.; Guennou, C.; Seaton, D. B.; Gibson, S. E.; Auchere, F.
2016-01-01
The reversal of the solar polar magnetic field is notoriously hard to pin down due to the extreme viewing angle of the pole. In Cycle 24, the southern polar field reversal can be pinpointed with high accuracy due to a large-scale pseudostreamer that formed over the pole and persisted for approximately a year. We tracked the size and shape of this structure with multiple observations and analysis techniques including PROBA2/SWAP EUV images, AIA EUV images, CoMP polarization data, and 3D tomographic reconstructions. We find that the heliospheric field reversed polarity in February 2014, whereas in the photosphere, the last vestiges of the previous polar field polarity remained until March 2015. We present here the evolution of the structure and describe its identification in the Fe XII 1074nm coronal emission line, sensitive to the Hanle effect in the corona.
Filpo-Perez, Carolina; Bramante, Clovis Monteiro; Villas-Boas, Marcelo Haas; Húngaro Duarte, Marco Antonio; Versiani, Marco Aurélio; Ordinola-Zapata, Ronald
2015-02-01
The aim of this study was to evaluate the morphologic aspects of the root canal anatomy of the distal root of a mandibular first molar using micro-computed tomographic analysis. One-hundred distal roots of mandibular first molars were scanned using a micro-computed tomographic device at an isotropic resolution of 19.6 μm. The percentage frequency distribution of the morphologic configuration of the root canal was performed according to the Vertucci classification system. Two-dimensional parameters (area, perimeter, roundness, aspect ratio, and major and minor diameters) and the cross-sectional shape of the root canal were analyzed in the apical third at every 1-mm interval from the main apical foramen in roots presenting Vertucci types I and II configurations (n = 79). Data were statistically compared using the Kruskal-Wallis and Dunn tests with a significance level set at 5%. Seventy-six percent of the distal roots had a single root canal. Two, three, and four canals were found in 13%, 8%, and 3% of the sample, respectively. In 13 specimens, the configuration of the root canal did not fit into Vertucci's classification. Overall, 2-dimensional parameter values significantly increased at the 3-mm level (P < .05). The prevalence of oval canals was higher at the 1-mm level and decreased at the 5-mm level in which long oval and flattened canals were more prevalent. The distal roots of the mandibular first molars showed a high prevalence of single root canals. The prevalence of long oval and flattened canals increased in the coronal direction. In 13% of the samples, canal configurations that were not included in Vertucci's configuration system were found. Copyright © 2015 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Hecht, Harvey S; Narula, Jagat; Fearon, William F
2016-07-08
Invasive fractional flow reserve (FFR) is now the gold standard for intervention. Noninvasive functional imaging analyses derived from coronary computed tomographic angiography (CTA) offer alternatives for evaluating lesion-specific ischemia. CT-FFR, CT myocardial perfusion imaging, and transluminal attenuation gradient/corrected contrast opacification have been studied using invasive FFR as the gold standard. CT-FFR has demonstrated significant improvement in specificity and positive predictive value compared with CTA alone for predicting FFR of ≤0.80, as well as decreasing the frequency of nonobstructive invasive coronary angiography. High-risk plaque characteristics have also been strongly implicated in abnormal FFR. Myocardial computed tomographic perfusion is an alternative method with promising results; it involves more radiation and contrast. Transluminal attenuation gradient/corrected contrast opacification is more controversial and may be more related to vessel diameter than stenosis. Important considerations remain: (1) improvement of CTA quality to decrease unevaluable studies, (2) is the diagnostic accuracy of CT-FFR sufficient? (3) can CT-FFR guide intervention without invasive FFR confirmation? (4) what are the long-term outcomes of CT-FFR-guided treatment and how do they compare with other functional imaging-guided paradigms? (5) what degree of stenosis on CTA warrants CT-FFR? (6) how should high-risk plaque be incorporated into treatment decisions? (7) how will CT-FFR influence other functional imaging test utilization, and what will be the effect on the practice of cardiology? (8) will a workstation-based CT-FFR be mandatory? Rapid progress to date suggests that CTA-based lesion-specific ischemia will be the gatekeeper to the cardiac catheterization laboratory and will transform the world of intervention. © 2016 American Heart Association, Inc.
MicroCT with energy-resolved photon-counting detectors
Wang, X; Meier, D; Mikkelsen, S; Maehlum, G E; Wagenaar, D J; Tsui, BMW; Patt, B E; Frey, E C
2011-01-01
The goal of this paper was to investigate the benefits that could be realistically achieved on a microCT imaging system with an energy-resolved photon-counting x-ray detector. To this end, we built and evaluated a prototype microCT system based on such a detector. The detector is based on cadmium telluride (CdTe) radiation sensors and application-specific integrated circuit (ASIC) readouts. Each detector pixel can simultaneously count x-ray photons above six energy thresholds, providing the capability for energy-selective x-ray imaging. We tested the spectroscopic performance of the system using polychromatic x-ray radiation and various filtering materials with Kabsorption edges. Tomographic images were then acquired of a cylindrical PMMA phantom containing holes filled with various materials. Results were also compared with those acquired using an intensity-integrating x-ray detector and single-energy (i.e. non-energy-selective) CT. This paper describes the functionality and performance of the system, and presents preliminary spectroscopic and tomographic results. The spectroscopic experiments showed that the energy-resolved photon-counting detector was capable of measuring energy spectra from polychromatic sources like a standard x-ray tube, and resolving absorption edges present in the energy range used for imaging. However, the spectral quality was degraded by spectral distortions resulting from degrading factors, including finite energy resolution and charge sharing. We developed a simple charge-sharing model to reproduce these distortions. The tomographic experiments showed that the availability of multiple energy thresholds in the photon-counting detector allowed us to simultaneously measure target-to-background contrasts in different energy ranges. Compared with single-energy CT with an integrating detector, this feature was especially useful to improve differentiation of materials with different attenuation coefficient energy dependences. PMID:21464527
On the use of helium-filled soap bubbles for large-scale tomographic PIV in wind tunnel experiments
NASA Astrophysics Data System (ADS)
Scarano, Fulvio; Ghaemi, Sina; Caridi, Giuseppe Carlo Alp; Bosbach, Johannes; Dierksheide, Uwe; Sciacchitano, Andrea
2015-02-01
The flow-tracing fidelity of sub-millimetre diameter helium-filled soap bubbles (HFSB) for low-speed aerodynamics is studied. The main interest of using HFSB in relation to micron-size droplets is the large amount of scattered light, enabling larger-scale three-dimensional experiments by tomographic PIV. The assessment of aerodynamic behaviour closely follows the method proposed in the early work of Kerho and Bragg (Exp Fluids 50:929-948, 1994) who evaluated the tracer trajectories around the stagnation region at the leading edge of an airfoil. The conclusions of the latter investigation differ from the present work, which concludes sub-millimetre HFSB do represent a valid alternative for quantitative velocimetry in wind tunnel aerodynamic experiments. The flow stagnating ahead of a circular cylinder of 25 mm diameter is considered at speeds up to 30 m/s. The tracers are injected in the free-stream and high-speed PIV, and PTV are used to obtain the velocity field distribution. A qualitative assessment based on streamlines is followed by acceleration and slip velocity measurements using PIV experiments with fog droplets as a term of reference. The tracing fidelity is controlled by the flow rates of helium, liquid soap and air in HFSB production. A characteristic time response, defined as the ratio of slip velocity and the fluid acceleration, is obtained. The feasibility of performing time-resolved tomographic PIV measurements over large volumes in aerodynamic wind tunnels is also studied. The flow past a 5-cm-diameter cylinder is measured over a volume of 20 × 20 × 12 cm3 at a rate of 2 kHz. The achieved seeding density of <0.01 ppp enables resolving the Kármán vortices, whereas turbulent sub-structures cannot be captured.
Bayram, H Melike; Bayram, Emre; Ocak, Mert; Uygun, Ahmet Demirhan; Celik, Hakan Hamdi
2017-07-01
The aim of the present study was to evaluate the frequency of dentinal microcracks observed after root canal preparation with ProTaper Universal (PTU; Dentsply Tulsa Dental Specialties, Tulsa, OK), ProTaper Gold (PTG; Dentsply Tulsa Dental Specialties), Self-Adjusting File (SAF; ReDent Nova, Ra'anana, Israel), and XP-endo Shaper (XP; FKG Dentaire, La Chaux-de-Fonds, Switzerland) instruments using micro-computed tomographic (CT) analysis. Forty extracted human mandibular premolars having single-canal and straight root were randomly assigned to 4 experimental groups (n = 10) according to the different nickel-titanium systems used for root canal preparation: PTU, PTG, SAF, and XP. In the SAF and XP groups, the canals were first prepared with a K-file until #25 at the working length, and then the SAF or XP files were used. The specimens were scanned using high-resolution micro-computed tomographic imaging before and after root canal preparation. Afterward, preoperative and postoperative cross-sectional images of the teeth were screened to identify the presence of dentinal defects. For each group, the number of microcracks was determined as a percentage rate. The McNemar test was used to determine significant differences before and after instrumentation. The level of significance was set at P ≤ .05. The PTU system significantly increased the percentage rate of microcracks compared with preoperative specimens (P < .05). No new dentinal microcracks were observed in the PTG, SAF, or XP groups. Root canal preparations with the PTG, SAF, and XP systems did not induce the formation of new dentinal microcracks on straight root canals of mandibular premolars. Copyright © 2017 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Finite frequency shear wave splitting tomography: a model space search approach
NASA Astrophysics Data System (ADS)
Mondal, P.; Long, M. D.
2017-12-01
Observations of seismic anisotropy provide key constraints on past and present mantle deformation. A common method for upper mantle anisotropy is to measure shear wave splitting parameters (delay time and fast direction). However, the interpretation is not straightforward, because splitting measurements represent an integration of structure along the ray path. A tomographic approach that allows for localization of anisotropy is desirable; however, tomographic inversion for anisotropic structure is a daunting task, since 21 parameters are needed to describe general anisotropy. Such a large parameter space does not allow a straightforward application of tomographic inversion. Building on previous work on finite frequency shear wave splitting tomography, this study aims to develop a framework for SKS splitting tomography with a new parameterization of anisotropy and a model space search approach. We reparameterize the full elastic tensor, reducing the number of parameters to three (a measure of strength based on symmetry considerations for olivine, plus the dip and azimuth of the fast symmetry axis). We compute Born-approximation finite frequency sensitivity kernels relating model perturbations to splitting intensity observations. The strong dependence of the sensitivity kernels on the starting anisotropic model, and thus the strong non-linearity of the inverse problem, makes a linearized inversion infeasible. Therefore, we implement a Markov Chain Monte Carlo technique in the inversion procedure. We have performed tests with synthetic data sets to evaluate computational costs and infer the resolving power of our algorithm for synthetic models with multiple anisotropic layers. Our technique can resolve anisotropic parameters on length scales of ˜50 km for realistic station and event configurations for dense broadband experiments. We are proceeding towards applications to real data sets, with an initial focus on the High Lava Plains of Oregon.
4D x-ray phase contrast tomography for repeatable motion of biological samples
NASA Astrophysics Data System (ADS)
Hoshino, Masato; Uesugi, Kentaro; Yagi, Naoto
2016-09-01
X-ray phase contrast tomography based on a grating interferometer was applied to fast and dynamic measurements of biological samples. To achieve this, the scanning procedure in the tomographic scan was improved. A triangle-shaped voltage signal from a waveform generator to a Piezo stage was used for the fast phase stepping in the grating interferometer. In addition, an optical fiber coupled x-ray scientific CMOS camera was used to achieve fast and highly efficient image acquisitions. These optimizations made it possible to perform an x-ray phase contrast tomographic measurement within an 8 min scan with density resolution of 2.4 mg/cm3. A maximum volume size of 13 × 13 × 6 mm3 was obtained with a single tomographic measurement with a voxel size of 6.5 μm. The scanning procedure using the triangle wave was applied to four-dimensional measurements in which highly sensitive three-dimensional x-ray imaging and a time-resolved dynamic measurement of biological samples were combined. A fresh tendon in the tail of a rat was measured under a uniaxial stretching and releasing condition. To maintain the freshness of the sample during four-dimensional phase contrast tomography, the temperature of the bathing liquid of the sample was kept below 10° using a simple cooling system. The time-resolved deformation of the tendon and each fascicle was measured with a temporal resolution of 5.7 Hz. Evaluations of cross-sectional area size, length of the axis, and mass density in the fascicle during a stretching process provided a basis for quantitative analysis of the deformation of tendon fascicle.
4D x-ray phase contrast tomography for repeatable motion of biological samples.
Hoshino, Masato; Uesugi, Kentaro; Yagi, Naoto
2016-09-01
X-ray phase contrast tomography based on a grating interferometer was applied to fast and dynamic measurements of biological samples. To achieve this, the scanning procedure in the tomographic scan was improved. A triangle-shaped voltage signal from a waveform generator to a Piezo stage was used for the fast phase stepping in the grating interferometer. In addition, an optical fiber coupled x-ray scientific CMOS camera was used to achieve fast and highly efficient image acquisitions. These optimizations made it possible to perform an x-ray phase contrast tomographic measurement within an 8 min scan with density resolution of 2.4 mg/cm 3 . A maximum volume size of 13 × 13 × 6 mm 3 was obtained with a single tomographic measurement with a voxel size of 6.5 μm. The scanning procedure using the triangle wave was applied to four-dimensional measurements in which highly sensitive three-dimensional x-ray imaging and a time-resolved dynamic measurement of biological samples were combined. A fresh tendon in the tail of a rat was measured under a uniaxial stretching and releasing condition. To maintain the freshness of the sample during four-dimensional phase contrast tomography, the temperature of the bathing liquid of the sample was kept below 10° using a simple cooling system. The time-resolved deformation of the tendon and each fascicle was measured with a temporal resolution of 5.7 Hz. Evaluations of cross-sectional area size, length of the axis, and mass density in the fascicle during a stretching process provided a basis for quantitative analysis of the deformation of tendon fascicle.
Anolik, Rachel A; Allori, Alexander C; Pourtaheri, Navid; Rogers, Gary F; Marcus, Jeffrey R
2016-05-01
The purpose of this study was to evaluate the utility of a previously validated interfrontal angle for classification of severity of metopic synostosis and as an aid to operative decision-making. An expert panel was asked to study 30 cases ranging from minor to severe metopic synostosis. Based on computed tomographic images of the skull and clinical photographs, they classified the severity of trigonocephaly (1 = normal, 2 = mild, 3 = moderate, and 4 = severe) and management (0 = nonoperative and 1 = operative). The severity scores and management reported by experts were then pooled and matched with the interfrontal angle computed from each respective computed tomographic scan. A threshold was identified at which most experts agree on operative management. Expert severity scores were higher for more acute interfrontal angles. There was a high concordance at the extremes of classifications, severe (4) and normal (1) (p < 0.0001); however, between interfrontal angles of 114.3 and 136.1 degrees, there exists a "gray zone," with severe discordance in expert rankings. An operative threshold of 118.2 degrees was identified, with the interfrontal angle able to predict the expert panel's decision to proceed with surgery 87.6 percent of the time. The interfrontal angle has been previously validated as a simple, accurate, and reproducible means for diagnosing trigonocephaly, but must be obtained from computed tomographic data. In this article, the authors demonstrate that the interfrontal angle can be used to further characterize the severity of trigonocephaly. It also correlated with expert decision-making for operative versus nonoperative management. This tool may be used as an adjunct to clinical decision-making when the decision to proceed with surgery may not be straightforward. Diagnostic, V.
MicroCT with energy-resolved photon-counting detectors.
Wang, X; Meier, D; Mikkelsen, S; Maehlum, G E; Wagenaar, D J; Tsui, B M W; Patt, B E; Frey, E C
2011-05-07
The goal of this paper was to investigate the benefits that could be realistically achieved on a microCT imaging system with an energy-resolved photon-counting x-ray detector. To this end, we built and evaluated a prototype microCT system based on such a detector. The detector is based on cadmium telluride (CdTe) radiation sensors and application-specific integrated circuit (ASIC) readouts. Each detector pixel can simultaneously count x-ray photons above six energy thresholds, providing the capability for energy-selective x-ray imaging. We tested the spectroscopic performance of the system using polychromatic x-ray radiation and various filtering materials with K-absorption edges. Tomographic images were then acquired of a cylindrical PMMA phantom containing holes filled with various materials. Results were also compared with those acquired using an intensity-integrating x-ray detector and single-energy (i.e. non-energy-selective) CT. This paper describes the functionality and performance of the system, and presents preliminary spectroscopic and tomographic results. The spectroscopic experiments showed that the energy-resolved photon-counting detector was capable of measuring energy spectra from polychromatic sources like a standard x-ray tube, and resolving absorption edges present in the energy range used for imaging. However, the spectral quality was degraded by spectral distortions resulting from degrading factors, including finite energy resolution and charge sharing. We developed a simple charge-sharing model to reproduce these distortions. The tomographic experiments showed that the availability of multiple energy thresholds in the photon-counting detector allowed us to simultaneously measure target-to-background contrasts in different energy ranges. Compared with single-energy CT with an integrating detector, this feature was especially useful to improve differentiation of materials with different attenuation coefficient energy dependences.
NASA Astrophysics Data System (ADS)
Riffel, Katharina; Sebastian, Donner; Shaiganfar, Reza; Wagner, Thomas; Dörner, Steffen
2016-04-01
The MAX DOAS-Method (Multi-AXis Differential Optical Absorption Spectroscopy) is used to analyze different trace gases (e.g. NO2, SO2, HCHO) at the same time and to determine the trace gas vertical column density (vertically integrated concentration). In summer 2015 we performed car-MAX-DOAS measurements in Romania during the AROMAT2 campaign. We encircled Bucharest at different weather situations and different times of the day. Afterwards the total NOx emissions were derived from the mobile MAX-DOAS observations in combination with wind data. In Germany we performed the same measurement procedure in fall/ winter/ spring 2015 /2016 by encircling the cities Mainz and Frankfurt. For the setting we mounted two MAX-DOAS instruments with different viewing directions (forward and backward) on the roof of a car. One instrument is a commercial mini MAX-DOAS that is built by the German company Hoffmann Messtechnik. The second one was built at the MPI in Mainz. This so-called Tube MAX-DOAS uses an AVANTES spectrometer with better optical characteristics than Hoffmann's mini MAX-DOAS. The advantage of two instruments working at the same time is (besides redundancy) that localized emission plumes can be measured from different directions at different locations. Thus, especially for emission plumes from power plants, tomographic methods can be applied to derive information about the plume altitude. Car-MAX-DOAS observations can cover large areas at a short time with reasonable resolution (depending on the speed of the car and the instruments integration time). Thus these measurements are well suited to validate satellites observations. This work will show the first AROMAT2 results of NOx emissions derived in Romania and in the Rhein-Main region, which is one of the most polluted area in Germany.
A multiresolution inversion for imaging the ionosphere
NASA Astrophysics Data System (ADS)
Yin, Ping; Zheng, Ya-Nan; Mitchell, Cathryn N.; Li, Bo
2017-06-01
Ionospheric tomography has been widely employed in imaging the large-scale ionospheric structures at both quiet and storm times. However, the tomographic algorithms to date have not been very effective in imaging of medium- and small-scale ionospheric structures due to limitations of uneven ground-based data distributions and the algorithm itself. Further, the effect of the density and quantity of Global Navigation Satellite Systems data that could help improve the tomographic results for the certain algorithm remains unclear in much of the literature. In this paper, a new multipass tomographic algorithm is proposed to conduct the inversion using intensive ground GPS observation data and is demonstrated over the U.S. West Coast during the period of 16-18 March 2015 which includes an ionospheric storm period. The characteristics of the multipass inversion algorithm are analyzed by comparing tomographic results with independent ionosonde data and Center for Orbit Determination in Europe total electron content estimates. Then, several ground data sets with different data distributions are grouped from the same data source in order to investigate the impact of the density of ground stations on ionospheric tomography results. Finally, it is concluded that the multipass inversion approach offers an improvement. The ground data density can affect tomographic results but only offers improvements up to a density of around one receiver every 150 to 200 km. When only GPS satellites are tracked there is no clear advantage in increasing the density of receivers beyond this level, although this may change if multiple constellations are monitored from each receiving station in the future.
Computed tomographic contrast tenography of the digital flexor tendon sheath of the equine hindlimb.
Agass, Rachel; Dixon, Jonathon; Fraser, Barny
2018-05-01
Pre-surgical investigation of digital flexor tendon sheath pathology remains challenging with current standard imaging techniques. The aim of this prospective, anatomical, pilot study was to describe the anatomy of the equine hind limb digital flexor tendon sheath using a combination of computed tomography (CT) and computed tomographic contrast tenography in clinically normal cadaver limbs. Ten pairs of hind limbs with no external abnormalities were examined from the level of the tarsometatarsal joint distally. Limbs initially underwent non-contrast CT examination using 120 kVp, 300 mAs, and 1.5 mm slice thickness. Sixty millilitres of ioversol iodinated contrast media and saline (final concentration 100 mg/ml) were injected using a basilar sesamoidean approach. The computed tomographic contrast tenography examination was then repeated, before dissection of the specimens to compare gross and imaging findings. The combined CT and computed tomographic contrast tenography examinations provided excellent anatomical detail of intra-thecal structures. The borders of the superficial and deep digital flexor tendons, and the manica flexoria were consistently identifiable in all limbs. Detailed anatomy including that of the mesotenons, two of which are previously undescribed, and the plantar annular ligament were also consistently identifiable. Dissection of all 10 pairs of limbs revealed there to be no pathology, in accordance with the imaging findings. In conclusion, the combination of CT and computed tomographic contrast tenography may be useful adjunctive diagnostic techniques to define digital flexor tendon sheath pathology prior to surgical exploration in horses. © 2017 American College of Veterinary Radiology.
Sóvágó, Judit; Farde, Lars; Halldin, Christer; Langer, Oliver; Laszlovszky, István; Kiss, Béla; Gulyás, Balázs
2004-10-01
The dopamine-D3 receptor is of special interest due to its postulated role in the pathophysiology and treatment of schizophrenia and Parkinson's Disease. Increasing evidences support the assumption that the D3 receptors are occupied to a high degree by dopamine at physiological conditions. Research on the functional role of the D3 receptors in brain has however been hampered by the lack of D3 selective ligands. In the present Positron Emission Tomography (PET) study the binding of the novel, putative dopamine-D3 receptor ligand, [11C]RGH-1756 was characterized in the cynomolgus monkey brain. [11C]RGH-1756 was rather homogenously distributed in brain and the regional binding potential (BP) values ranged between 0.17 and 0.48. Pretreatment with unlabelled RGH-1756 decreased radioligand binding to the level of the cerebellum in most brain areas. The regional BP values were lower after intravenous injection of a higher mass of RGH-1756, indicating saturable binding of [11C]RGH-1756. The D2/D3 antagonist raclopride partly inhibited the binding of [11C]RGH-1756 in several brain areas, including the striatum, mesencephalon and neocortex, whereas the 5HT(1A) antagonist WAY-100635 had no evident effect on [11C]RGH-1756 binding. Despite the promising binding characteristics of RGH-1756 in vitro the present PET-study indicates that [11C]RGH-1756 provides a low signal for specific binding to the D3 receptor in vivo. One explanation is that the favorable binding characteristics of RGH-1756 in vitro are not manifested in vivo. Alternatively, the results may support the hypothesis that the dopamine-D3 receptors are indeed occupied to a high extent by dopamine in vivo and thus not available for radioligand binding.
Pietzsch, J; Bergmann, R; Wuest, F; Pawelke, B; Hultsch, C; van den Hoff, J
2005-12-01
The human organism is exposed to numerous processes that generate reactive oxygen species (ROS). ROS may directly or indirectly cause oxidative modification and damage of proteins. Protein oxidation is regarded as a crucial event in the pathogenesis of various diseases ranging from rheumatoid arthritis to Alzheimer's disease and atherosclerosis. As a representative example, oxidation of low density lipoprotein (LDL) is regarded as a crucial event in atherogenesis. Data concerning the role of circulating oxidized LDL (oxLDL) in the development and outcome of diseases are scarce. One reason for this is the shortage of methods for direct assessment of the metabolic fate of circulating oxLDL in vivo. We present an improved methodology based on the radiolabelling of apoB-100 of native LDL (nLDL) and oxLDL, respectively, with the positron emitter fluorine-18 ((18)F) by conjugation with N-succinimidyl-4-[(18)F]fluorobenzoate ([(18)F]SFB). Radiolabelling of both nLDL and oxLDL using [(18)F]SFB causes neither additional oxidative structural modifications of LDL lipids and proteins nor alteration of their biological activity and functionality, respectively, in vitro. The method was further evaluated with respect to the radiopharmacological properties of both [(18)F]fluorobenzoylated nLDL and oxLDL by biodistribution studies in male Wistar rats. The metabolic fate of [(18)F]fluorobenzoylated nLDL and oxLDL in rats in vivo was further delineated by dynamic positron emission tomography (PET) using a dedicated small animal tomograph (spatial resolution of 2 mm). From this study we conclude that the use of [(18)F]FB-labelled LDL particles is an attractive alternative to, e.g., LDL iodination methods, and is of value to characterize and to discriminate the kinetics and the metabolic fate of nLDL and oxLDL in small animals in vivo.
Vallabhajosula, Shankar
2007-11-01
Molecular imaging is the visualization, characterization, and measurement of biological processes at the molecular and cellular levels in a living system. At present, positron emission tomography/computed tomography (PET/CT) is one the most rapidly growing areas of medical imaging, with many applications in the clinical management of patients with cancer. Although [(18)F]fluorodeoxyglucose (FDG)-PET/CT imaging provides high specificity and sensitivity in several kinds of cancer and has many applications, it is important to recognize that FDG is not a "specific" radiotracer for imaging malignant disease. Highly "tumor-specific" and "tumor cell signal-specific" PET radiopharmaceuticals are essential to meet the growing demand of radioisotope-based molecular imaging technology. In the last 15 years, many alternative PET tracers have been proposed and evaluated in preclinical and clinical studies to characterize the tumor biology more appropriately. The potential clinical utility of several (18)F-labeled radiotracers (eg, fluoride, FDOPA, FLT, FMISO, FES, and FCH) is being reviewed by several investigators in this issue. An overview of design and development of (18)F-labeled PET radiopharmaceuticals, radiochemistry, and mechanism(s) of tumor cell uptake and localization of radiotracers are presented here. The approval of clinical indications for FDG-PET in the year 2000 by the Food and Drug Administration, based on a review of literature, was a major breakthrough to the rapid incorporation of PET into nuclear medicine practice, particularly in oncology. Approval of a radiopharmaceutical typically involves submission of a "New Drug Application" by a manufacturer or a company clearly documenting 2 major aspects of the drug: (1) manufacturing of PET drug using current good manufacturing practices and (2) the safety and effectiveness of a drug with specific indications. The potential routine clinical utility of (18)F-labeled PET radiopharmaceuticals depends also on regulatory compliance in addition to documentation of potential safety and efficacy by various investigators.
NASA Astrophysics Data System (ADS)
Alessio, R.; Nogueira, L. P.; Salata, C.; Mantuano, A.; Almeida, A. P.; Braz, D.; de Almeida, C. E.; Tromba, G.; Barroso, R. C.
2015-11-01
Microporosities play important biologic and mechanical roles on health. One of the side effects caused by some chemotherapy drugs is the induction of amenorrhea, temporary or not, in premenopausal women, with a consequent decrease in estrogen production, which can lead to cortical bone changes. In the present work, the femur diaphysis of rats treated with chemotherapy drugs were evaluated by 3D morphometric parameters using synchrotron radiation microtomography. Control animals were also evaluated for comparison. The 3D tomographic images were obtained at the SYRMEP (SYnchrotron Radiation for MEdical Physics) beamline at the ELETTRA Synchrotron Laboratory in Trieste, Italy. Results showed significant differences in morphometric parameters measured from the 3D images of femur diaphysis of rats.
Sparsity Aware Adaptive Radar Sensor Imaging in Complex Scattering Environments
2015-06-15
while meeting the requirement on the peak to average power ratio. Third, we study impact of waveform encoding on nonlinear electromagnetic tomographic...Enyue Lu. Time Domain Electromagnetic Tomography Using Propagation and Backpropagation Method, IEEE International Conference on Image Processing...Received Paper 3.00 4.00 Yuanwei Jin, Chengdon Dong, Enyue Lu. Waveform Encoding for Nonlinear Electromagnetic Tomographic Imaging, IEEE Global
An Analysis for Capital Expenditure Decisions at a Naval Regional Medical Center.
1981-12-01
Service Equipment Review Committee 1. Portable defibrilator Computed tomographic scanner and cardioscope 2. ECG cart Automated blood cell counter 3. Gas...system sterilizer Gas system sterilizer 4. Automated blood cell Portable defibrilator and counter cardioscope 5. Computed tomographic ECG cart scanner...dictating and automated typing) systems. e. Filing equipment f. Automatic data processing equipment including data communications equipment. g
Analysis of 21-cm tomographic data
NASA Astrophysics Data System (ADS)
Mellema, Garrelt; Giri, Sambit; Ghara, Raghuna
2018-05-01
The future SKA1-Low radio telescope will be powerful enough to produce tomographic images of the 21-cm signal from the Epoch of Reionization. Here we address how to identify ionized regions in such data sets, taking into account the resolution and noise levels associated with SKA1-Low. We describe three methods of which one, superpixel oversegmentation, consistently performs best.
1986-03-10
and P. Frangos , "Inverse Scattering for Dielectric Media", Annual OSA Meeting, Wash. D.C., Oct. 1985. Invited Presentations 1. N. Farhat, "Tomographic...Optical Computing", DARPA Briefing, ~~April 1985. ... -7--.. , 1% If .% P . .% .% *-. 7777~14e 7-7. K-7 77 Theses 0 P.V. Frangos , "The Electromagnetic
Volume Segmentation and Ghost Particles
NASA Astrophysics Data System (ADS)
Ziskin, Isaac; Adrian, Ronald
2011-11-01
Volume Segmentation Tomographic PIV (VS-TPIV) is a type of tomographic PIV in which images of particles in a relatively thick volume are segmented into images on a set of much thinner volumes that may be approximated as planes, as in 2D planar PIV. The planes of images can be analysed by standard mono-PIV, and the volume of flow vectors can be recreated by assembling the planes of vectors. The interrogation process is similar to a Holographic PIV analysis, except that the planes of image data are extracted from two-dimensional camera images of the volume of particles instead of three-dimensional holographic images. Like the tomographic PIV method using the MART algorithm, Volume Segmentation requires at least two cameras and works best with three or four. Unlike the MART method, Volume Segmentation does not require reconstruction of individual particle images one pixel at a time and it does not require an iterative process, so it operates much faster. As in all tomographic reconstruction strategies, ambiguities known as ghost particles are produced in the segmentation process. The effect of these ghost particles on the PIV measurement is discussed. This research was supported by Contract 79419-001-09, Los Alamos National Laboratory.
Creating three-dimensional tooth models from tomographic images.
Lima da Silva, Isaac Newton; Barbosa, Gustavo Frainer; Soares, Rodrigo Borowski Grecco; Beltrao, Maria Cecilia Gomes; Spohr, Ana Maria; Mota, Eduardo Golcalves; Oshima, Hugo Mitsuo Silva; Burnett, Luiz Henrique
2008-01-01
The use of Finite Element Analysis (FEA) is becoming very frequent in Dentistry. However, most of the three-dimensional models presented by the literature for teeth are limited in terms of geometry. Discrepancy in shape and dimensions can cause wrong results to occur. Sharp cusps and faceted contour can produce stress concentrations, which are incoherent with the reality. The aim of this study was the processing of tomographic images in order to develop an advanced three-dimensional reconstruction of the anatomy of a molar tooth and the integration of the resulting solid with commercially available CAD/CAE software. Computed tomographic images were obtained from 0.5 mm thick slices of mandibular molar and transferred to commercial cad software. Once the point cloud data have been generated, the work on these points started to get to the solid model of the tooth with Pro/Engineer software. The obtained tooth model showed very accurate shape and dimensions, as it was obtained from real tooth data with error of 0.0 to -0.8 mm. The methodology presented was efficient for creating a biomodel of a tooth from tomographic images that realistically represented its anatomy.
Experimental demonstration of laser tomographic adaptive optics on a 30-meter telescope at 800 nm
NASA Astrophysics Data System (ADS)
Ammons, S., Mark; Johnson, Luke; Kupke, Renate; Gavel, Donald T.; Max, Claire E.
2010-07-01
A critical goal in the next decade is to develop techniques that will extend Adaptive Optics correction to visible wavelengths on Extremely Large Telescopes (ELTs). We demonstrate in the laboratory the highly accurate atmospheric tomography necessary to defeat the cone effect on ELTs, an essential milestone on the path to this capability. We simulate a high-order Laser Tomographic AO System for a 30-meter telescope with the LTAO/MOAO testbed at UCSC. Eight Sodium Laser Guide Stars (LGSs) are sensed by 99x99 Shack-Hartmann wavefront sensors over 75". The AO system is diffraction-limited at a science wavelength of 800 nm (S ~ 6-9%) over a field of regard of 20" diameter. Openloop WFS systematic error is observed to be proportional to the total input atmospheric disturbance and is nearly the dominant error budget term (81 nm RMS), exceeded only by tomographic wavefront estimation error (92 nm RMS). The total residual wavefront error for this experiment is comparable to that expected for wide-field tomographic adaptive optics systems of similar wavefront sensor order and LGS constellation geometry planned for Extremely Large Telescopes.
Kubo, S; Nakata, H; Sugauchi, Y; Yokota, N; Yoshimine, T
2000-05-01
The preoperative localization of superficial intracranial lesions is often necessary for accurate burr hole placement or craniotomy siting. It is not always easy, however, to localize the lesions over the scalp working only from computed tomographic images. We developed a simple method for such localization using a laser pointer during the preoperative computed tomographic examination. The angle of incidence, extending from a point on the scalp to the center of the computed tomographic image, is measured by the software included with the scanner. In the gantry, at the same angle as on the image, a laser is beamed from a handmade projector onto the patient's scalp toward the center of the gantry. The point illuminated on the patient's head corresponds to that on the image. The device and the method are described in detail herein. We applied this technique to mark the area for the craniotomy before surgery in five patients with superficial brain tumors. At the time of surgery, it was confirmed that the tumors were circumscribed precisely. The technique is easy to perform and useful in the preoperative planning for a craniotomy. In addition, the device is easily constructed and inexpensive.
TomoBank: a tomographic data repository for computational x-ray science
NASA Astrophysics Data System (ADS)
De Carlo, Francesco; Gürsoy, Doğa; Ching, Daniel J.; Joost Batenburg, K.; Ludwig, Wolfgang; Mancini, Lucia; Marone, Federica; Mokso, Rajmund; Pelt, Daniël M.; Sijbers, Jan; Rivers, Mark
2018-03-01
There is a widening gap between the fast advancement of computational methods for tomographic reconstruction and their successful implementation in production software at various synchrotron facilities. This is due in part to the lack of readily available instrument datasets and phantoms representative of real materials for validation and comparison of new numerical methods. Recent advancements in detector technology have made sub-second and multi-energy tomographic data collection possible (Gibbs et al 2015 Sci. Rep. 5 11824), but have also increased the demand to develop new reconstruction methods able to handle in situ (Pelt and Batenburg 2013 IEEE Trans. Image Process. 22 5238-51) and dynamic systems (Mohan et al 2015 IEEE Trans. Comput. Imaging 1 96-111) that can be quickly incorporated in beamline production software (Gürsoy et al 2014 J. Synchrotron Radiat. 21 1188-93). The x-ray tomography data bank, tomoBank, provides a repository of experimental and simulated datasets with the aim to foster collaboration among computational scientists, beamline scientists, and experimentalists and to accelerate the development and implementation of tomographic reconstruction methods for synchrotron facility production software by providing easy access to challenging datasets and their descriptors.
Tomographic imaging using poissonian detector data
Aspelmeier, Timo; Ebel, Gernot; Hoeschen, Christoph
2013-10-15
An image reconstruction method for reconstructing a tomographic image (f.sub.j) of a region of investigation within an object (1), comprises the steps of providing detector data (y.sub.i) comprising Poisson random values measured at an i-th of a plurality of different positions, e.g. i=(k,l) with pixel index k on a detector device and angular index l referring to both the angular position (.alpha..sub.l) and the rotation radius (r.sub.l) of the detector device (10) relative to the object (1), providing a predetermined system matrix A.sub.ij assigning a j-th voxel of the object (1) to the i-th detector data (y.sub.i), and reconstructing the tomographic image (f.sub.j) based on the detector data (y.sub.i), said reconstructing step including a procedure of minimizing a functional F(f) depending on the detector data (y.sub.i) and the system matrix A.sub.ij and additionally including a sparse or compressive representation of the object (1) in an orthobasis T, wherein the tomographic image (f.sub.j) represents the global minimum of the functional F(f). Furthermore, an imaging method and an imaging device using the image reconstruction method are described.
Dosimetry in small-animal CT using Monte Carlo simulations
NASA Astrophysics Data System (ADS)
Lee, C.-L.; Park, S.-J.; Jeon, P.-H.; Jo, B.-D.; Kim, H.-J.
2016-01-01
Small-animal computed tomography (micro-CT) imaging devices are increasingly being used in biological research. While investigators are mainly interested in high-contrast, low-noise, and high-resolution anatomical images, relatively large radiation doses are required, and there is also growing concern over the radiological risk from preclinical experiments. This study was conducted to determine the radiation dose in a mouse model for dosimetric estimates using the GEANT4 application for tomographic emission simulations (GATE) and to extend its techniques to various small-animal CT applications. Radiation dose simulations were performed with the same parameters as those for the measured micro-CT data, using the MOBY phantom, a pencil ion chamber and an electrometer with a CT detector. For physical validation of radiation dose, absorbed dose of brain and liver in mouse were evaluated to compare simulated results with physically measured data using thermoluminescent dosimeters (TLDs). The mean difference between simulated and measured data was less than 2.9% at 50 kVp X-ray source. The absorbed doses of 37 brain tissues and major organs of the mouse were evaluated according to kVp changes. The absorbed dose over all of the measurements in the brain (37 types of tissues) consistently increased and ranged from 42.4 to 104.0 mGy. Among the brain tissues, the absorbed dose of the hypothalamus (157.8-414.30 mGy) was the highest for the beams at 50-80 kVp, and that of the corpus callosum (11.2-26.6 mGy) was the lowest. These results can be used as a dosimetric database to control mouse doses and preclinical targeted radiotherapy experiments. In addition, to accurately calculate the mouse-absorbed dose, the X-ray spectrum, detector alignment, and uncertainty in the elemental composition of the simulated materials must be accurately modeled.
LITES and GROUP-C Mission Update: Ionosphere and Thermosphere Sensing from the ISS
NASA Astrophysics Data System (ADS)
Stephan, A. W.; Budzien, S. A.; Chakrabarti, S.; Hysell, D. L.; Powell, S. P.; Finn, S. C.; Cook, T.; Bishop, R. L.
2016-12-01
The Limb-imaging Ionospheric and Thermospheric Extreme-ultraviolet Spectrograph (LITES) and GPS Radio Occultation and Ultraviolet Photometer Co-located (GROUP-C) experiments are scheduled for launch to the International Space Station (ISS) in November 2016 as part of the Space Test Program Houston #5 payload (STP-H5). The two experiments provide technical development and risk-reduction for future space weather sensors suitable for ionospheric specification, space situational awareness, and data products for global ionosphere assimilative models. The combined instrument suite of these experiments offers a unique capability to study spatial and temporal variability of the thermosphere and ionosphere using multi-sensor and tomographic approaches. LITES is an imaging spectrograph that spans 60-140 nm and continuously acquires limb profiles of the ionosphere and thermosphere from 150-350 km altitude. GROUP-C includes a high-sensitivity far-ultraviolet photometer measuring horizontal ionospheric gradients and an advanced GPS receiver providing ionospheric electron density profiles and scintillation measurements. High-cadence limb images and nadir photometry from GROUP-C/LITES are combined to tomographically reconstruct high-fidelity two-dimensional volume emission rates within the ISS orbital plane. The GPS occultation receiver provides independent measurements to calibrate and validate advanced daytime ionospheric algorithms and nighttime tomography. The vantage from the ISS on the lower portion of the thermosphere and ionosphere will yield measurements complementary to the NASA GOLD and ICON missions which are expected to fly during the STP-H5 mission. We present a mission status update and available early orbit observations, and the opportunities for using these new data to help address questions regarding the complex and dynamic features of the low and middle latitude ionosphere-thermosphere system that have important implications for operational systems.
Post-processing methods of rendering and visualizing 3-D reconstructed tomographic images
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wong, S.T.C.
The purpose of this presentation is to discuss the computer processing techniques of tomographic images, after they have been generated by imaging scanners, for volume visualization. Volume visualization is concerned with the representation, manipulation, and rendering of volumetric data. Since the first digital images were produced from computed tomography (CT) scanners in the mid 1970s, applications of visualization in medicine have expanded dramatically. Today, three-dimensional (3D) medical visualization has expanded from using CT data, the first inherently digital source of 3D medical data, to using data from various medical imaging modalities, including magnetic resonance scanners, positron emission scanners, digital ultrasound,more » electronic and confocal microscopy, and other medical imaging modalities. We have advanced from rendering anatomy to aid diagnosis and visualize complex anatomic structures to planning and assisting surgery and radiation treatment. New, more accurate and cost-effective procedures for clinical services and biomedical research have become possible by integrating computer graphics technology with medical images. This trend is particularly noticeable in current market-driven health care environment. For example, interventional imaging, image-guided surgery, and stereotactic and visualization techniques are now stemming into surgical practice. In this presentation, we discuss only computer-display-based approaches of volumetric medical visualization. That is, we assume that the display device available is two-dimensional (2D) in nature and all analysis of multidimensional image data is to be carried out via the 2D screen of the device. There are technologies such as holography and virtual reality that do provide a {open_quotes}true 3D screen{close_quotes}. To confine the scope, this presentation will not discuss such approaches.« less
Wu, Abraham J; Bosch, Walter R; Chang, Daniel T; Hong, Theodore S; Jabbour, Salma K; Kleinberg, Lawrence R; Mamon, Harvey J; Thomas, Charles R; Goodman, Karyn A
2015-07-15
Current guidelines for esophageal cancer contouring are derived from traditional 2-dimensional fields based on bony landmarks, and they do not provide sufficient anatomic detail to ensure consistent contouring for more conformal radiation therapy techniques such as intensity modulated radiation therapy (IMRT). Therefore, we convened an expert panel with the specific aim to derive contouring guidelines and generate an atlas for the clinical target volume (CTV) in esophageal or gastroesophageal junction (GEJ) cancer. Eight expert academically based gastrointestinal radiation oncologists participated. Three sample cases were chosen: a GEJ cancer, a distal esophageal cancer, and a mid-upper esophageal cancer. Uniform computed tomographic (CT) simulation datasets and accompanying diagnostic positron emission tomographic/CT images were distributed to each expert, and the expert was instructed to generate gross tumor volume (GTV) and CTV contours for each case. All contours were aggregated and subjected to quantitative analysis to assess the degree of concordance between experts and to generate draft consensus contours. The panel then refined these contours to generate the contouring atlas. The κ statistics indicated substantial agreement between panelists for each of the 3 test cases. A consensus CTV atlas was generated for the 3 test cases, each representing common anatomic presentations of esophageal cancer. The panel agreed on guidelines and principles to facilitate the generalizability of the atlas to individual cases. This expert panel successfully reached agreement on contouring guidelines for esophageal and GEJ IMRT and generated a reference CTV atlas. This atlas will serve as a reference for IMRT contours for clinical practice and prospective trial design. Subsequent patterns of failure analyses of clinical datasets using these guidelines may require modification in the future. Copyright © 2015 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wu, Abraham J., E-mail: wua@mskcc.org; Bosch, Walter R.; Chang, Daniel T.
Purpose/Objective(s): Current guidelines for esophageal cancer contouring are derived from traditional 2-dimensional fields based on bony landmarks, and they do not provide sufficient anatomic detail to ensure consistent contouring for more conformal radiation therapy techniques such as intensity modulated radiation therapy (IMRT). Therefore, we convened an expert panel with the specific aim to derive contouring guidelines and generate an atlas for the clinical target volume (CTV) in esophageal or gastroesophageal junction (GEJ) cancer. Methods and Materials: Eight expert academically based gastrointestinal radiation oncologists participated. Three sample cases were chosen: a GEJ cancer, a distal esophageal cancer, and a mid-upper esophagealmore » cancer. Uniform computed tomographic (CT) simulation datasets and accompanying diagnostic positron emission tomographic/CT images were distributed to each expert, and the expert was instructed to generate gross tumor volume (GTV) and CTV contours for each case. All contours were aggregated and subjected to quantitative analysis to assess the degree of concordance between experts and to generate draft consensus contours. The panel then refined these contours to generate the contouring atlas. Results: The κ statistics indicated substantial agreement between panelists for each of the 3 test cases. A consensus CTV atlas was generated for the 3 test cases, each representing common anatomic presentations of esophageal cancer. The panel agreed on guidelines and principles to facilitate the generalizability of the atlas to individual cases. Conclusions: This expert panel successfully reached agreement on contouring guidelines for esophageal and GEJ IMRT and generated a reference CTV atlas. This atlas will serve as a reference for IMRT contours for clinical practice and prospective trial design. Subsequent patterns of failure analyses of clinical datasets using these guidelines may require modification in the future.« less
Critical examination of the uniformity requirements for single-photon emission computed tomography.
O'Connor, M K; Vermeersch, C
1991-01-01
It is generally recognized that single-photon emission computed tomography (SPECT) imposes very stringent requirements on gamma camera uniformity to prevent the occurrence of ring artifacts. The purpose of this study was to examine the relationship between nonuniformities in the planar data and the magnitude of the consequential ring artifacts in the transaxial data, and how the perception of these artifacts is influenced by factors such as reconstruction matrix size, reconstruction filter, and image noise. The study indicates that the relationship between ring artifact magnitude and image noise is essentially independent of the acquisition or reconstruction matrix sizes, but is strongly dependent upon the type of smoothing filter applied during the reconstruction process. Furthermore, the degree to which a ring artifact can be perceived above image noise is dependent on the size and location of the nonuniformity in the planar data, with small nonuniformities (1-2 pixels wide) close to the center of rotation being less perceptible than those further out (8-20 pixels). Small defects or nonuniformities close to the center of rotation are thought to cause the greatest potential corruption to tomographic data. The study indicates that such may not be the case. Hence the uniformity requirements for SPECT may be less demanding than was previously thought.
Schneider, Florian R; Mann, Alexander B; Konorov, Igor; Delso, Gaspar; Paul, Stephan; Ziegler, Sibylle I
2012-06-01
A one-day laboratory course on positron emission tomography (PET) for the education of physics students and PhD students in medical physics has been set up. In the course, the physical background and the principles of a PET scanner are introduced. Course attendees set the system in operation, calibrate it using a (22)Na point source and reconstruct different source geometries filled with (18)F. The PET scanner features an individual channel read-out of 96 lutetium oxyorthosilicate (LSO) scintillator crystals coupled to avalanche photodiodes (APD). The analog data of each APD are digitized by fast sampling analog to digital converters (SADC) and processed within field programmable gate arrays (FPGA) to extract amplitudes and time stamps. All SADCs are continuously sampling with a precise rate of 80MHz, which is synchronous for the whole system. The data is transmitted via USB to a Linux PC, where further processing and the image reconstruction are performed. The course attendees get an insight into detector techniques, modern read-out electronics, data acquisition and PET image reconstruction. In addition, a short introduction to some common software applications used in particle and high energy physics is part of the course. Copyright © 2011. Published by Elsevier GmbH.
Measuring the Epoch of Reionization using [CII] Intensity Mapping with TIME-Pilot
NASA Astrophysics Data System (ADS)
Crites, Abigail; Bock, James; Bradford, Matt; Bumble, Bruce; Chang, Tzu-Ching; Cheng, Yun-Ting; Cooray, Asantha R.; Hailey-Dunsheath, Steve; Hunacek, Jonathon; Li, Chao-Te; O'Brient, Roger; Shirokoff, Erik; Staniszewski, Zachary; Shiu, Corwin; Uzgil, Bade; Zemcov, Michael B.; Sun, Guochao
2017-01-01
TIME-Pilot (the Tomographic Ionized carbon Intensity Mapping Experiment) is a new instrument designed to probe the epoch of reionization (EoR) by measuring the 158 um ionized carbon emission line [CII] from redshift 5 - 9. TIME-Pilot will also probe the molecular gas content of the universe during the epoch spanning the peak of star formation (z ~ 1 -3) by making an intensity mapping measurement of the CO transitions in the TIME-Pilot band (CO(3-2), CO(4-3), CO(5-4), and CO(6-5)). I will describe the instrument we are building which is an R of ~100 spectrometer sensitive to the 200-300 GHz radiation. The camera is designed to measure the line emission from galaxies using an intensity mapping technique. This instrument will allow us to detect the [CII] clustering fluctuations from faint galaxies during EoR and compare these measurements to predicted [CII] amplitudes from current models. The CO measurements will allow us to constrain models for galaxies at lower redshift. The [CII] intensity mapping measurements that will be made with TIME-Pilot and detailed measurements made with future more sensitive mm-wavelength spectrometers are complimentary to 21-cm measurements of the EoR and complimentary to direct detections of high redshift galaxies with HST, ALMA, and, in the future, JWST.
Image quality phantom and parameters for high spatial resolution small-animal SPECT
NASA Astrophysics Data System (ADS)
Visser, Eric P.; Harteveld, Anita A.; Meeuwis, Antoi P. W.; Disselhorst, Jonathan A.; Beekman, Freek J.; Oyen, Wim J. G.; Boerman, Otto C.
2011-10-01
At present, generally accepted standards to characterize small-animal single photon emission tomographs (SPECT) do not exist. Whereas for small-animal positron emission tomography (PET), the NEMA NU 4-2008 guidelines are available, such standards are still lacking for small-animal SPECT. More specifically, a dedicated image quality (IQ) phantom and corresponding IQ parameters are absent. The structures of the existing PET IQ phantom are too large to fully characterize the sub-millimeter spatial resolution of modern multi-pinhole SPECT scanners, and its diameter will not fit into all scanners when operating in high spatial resolution mode. We therefore designed and constructed an adapted IQ phantom with smaller internal structures and external diameter, and a facility to guarantee complete filling of the smallest rods. The associated IQ parameters were adapted from NEMA NU 4. An additional parameter, effective whole-body sensitivity, was defined since this was considered relevant in view of the variable size of the field of view and the use of multiple bed positions as encountered in modern small-animal SPECT scanners. The usefulness of the phantom was demonstrated for 99mTc in a USPECT-II scanner operated in whole-body scanning mode using a multi-pinhole mouse collimator with 0.6 mm pinhole diameter.
NASA Astrophysics Data System (ADS)
Pablico-Lansigan, Michele H.; Situ, Shu F.; Samia, Anna Cristina S.
2013-05-01
Magnetic particle imaging (MPI) is an emerging biomedical imaging technology that allows the direct quantitative mapping of the spatial distribution of superparamagnetic iron oxide nanoparticles. MPI's increased sensitivity and short image acquisition times foster the creation of tomographic images with high temporal and spatial resolution. The contrast and sensitivity of MPI is envisioned to transcend those of other medical imaging modalities presently used, such as magnetic resonance imaging (MRI), X-ray scans, ultrasound, computed tomography (CT), positron emission tomography (PET) and single photon emission computed tomography (SPECT). In this review, we present an overview of the recent advances in the rapidly developing field of MPI. We begin with a basic introduction of the fundamentals of MPI, followed by some highlights over the past decade of the evolution of strategies and approaches used to improve this new imaging technique. We also examine the optimization of iron oxide nanoparticle tracers used for imaging, underscoring the importance of size homogeneity and surface engineering. Finally, we present some future research directions for MPI, emphasizing the novel and exciting opportunities that it offers as an important tool for real-time in vivo monitoring. All these opportunities and capabilities that MPI presents are now seen as potential breakthrough innovations in timely disease diagnosis, implant monitoring, and image-guided therapeutics.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Giacomelli, L.; Department of Physics, Università degli Studi di Milano-Bicocca, Milano; Conroy, S.
The Joint European Torus (JET, Culham, UK) is the largest tokamak in the world devoted to nuclear fusion experiments of magnetic confined Deuterium (D)/Deuterium-Tritium (DT) plasmas. Neutrons produced in these plasmas are measured using various types of neutron detectors and spectrometers. Two of these instruments on JET make use of organic liquid scintillator detectors. The neutron emission profile monitor implements 19 liquid scintillation counters to detect the 2.45 MeV neutron emission from D plasmas. A new compact neutron spectrometer is operational at JET since 2010 to measure the neutron energy spectra from both D and DT plasmas. Liquid scintillation detectorsmore » are sensitive to both neutron and gamma radiation but give light responses of different decay time such that pulse shape discrimination techniques can be applied to identify the neutron contribution of interest from the data. The most common technique consists of integrating the radiation pulse shapes within different ranges of their rising and/or trailing edges. In this article, a step forward in this type of analysis is presented. The method applies a tomographic analysis of the 3-dimensional neutron and gamma pulse shape and pulse height distribution data obtained from liquid scintillation detectors such that n/γ discrimination can be improved to lower energies and additional information can be gained on neutron contributions to the gamma events and vice versa.« less
NASA Astrophysics Data System (ADS)
Raczyński, L.; Moskal, P.; Kowalski, P.; Wiślicki, W.; Bednarski, T.; Białas, P.; Czerwiński, E.; Kapłon, Ł.; Kochanowski, A.; Korcyl, G.; Kowal, J.; Kozik, T.; Krzemień, W.; Kubicz, E.; Molenda, M.; Moskal, I.; Niedźwiecki, Sz.; Pałka, M.; Pawlik-Niedźwiecka, M.; Rudy, Z.; Salabura, P.; Sharma, N. G.; Silarski, M.; Słomski, A.; Smyrski, J.; Strzelecki, A.; Wieczorek, A.; Zieliński, M.; Zoń, N.
2014-11-01
Currently inorganic scintillator detectors are used in all commercial Time of Flight Positron Emission Tomograph (TOF-PET) devices. The J-PET collaboration investigates a possibility of construction of a PET scanner from plastic scintillators which would allow for single bed imaging of the whole human body. This paper describes a novel method of hit-position reconstruction based on sampled signals and an example of an application of the method for a single module with a 30 cm long plastic strip, read out on both ends by Hamamatsu R4998 photomultipliers. The sampling scheme to generate a vector with samples of a PET event waveform with respect to four user-defined amplitudes is introduced. The experimental setup provides irradiation of a chosen position in the plastic scintillator strip with an annihilation gamma quanta of energy 511 keV. The statistical test for a multivariate normal (MVN) distribution of measured vectors at a given position is developed, and it is shown that signals sampled at four thresholds in a voltage domain are approximately normally distributed variables. With the presented method of a vector analysis made out of waveform samples acquired with four thresholds, we obtain a spatial resolution of about 1 cm and a timing resolution of about 80 ps (σ).
Dual-Modality PET/Ultrasound imaging of the Prostate
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huber, Jennifer S.; Moses, William W.; Pouliot, Jean
2005-11-11
Functional imaging with positron emission tomography (PET)will detect malignant tumors in the prostate and/or prostate bed, as well as possibly help determine tumor ''aggressiveness''. However, the relative uptake in a prostate tumor can be so great that few other anatomical landmarks are visible in a PET image. Ultrasound imaging with a transrectal probe provides anatomical detail in the prostate region that can be co-registered with the sensitive functional information from the PET imaging. Imaging the prostate with both PET and transrectal ultrasound (TRUS) will help determine the location of any cancer within the prostate region. This dual-modality imaging should helpmore » provide better detection and treatment of prostate cancer. LBNL has built a high performance positron emission tomograph optimized to image the prostate.Compared to a standard whole-body PET camera, our prostate-optimized PET camera has the same sensitivity and resolution, less backgrounds and lower cost. We plan to develop the hardware and software tools needed for a validated dual PET/TRUS prostate imaging system. We also plan to develop dual prostate imaging with PET and external transabdominal ultrasound, in case the TRUS system is too uncomfortable for some patients. We present the design and intended clinical uses for these dual imaging systems.« less
Numerical study on simultaneous emission and transmission tomography in the MRI framework
NASA Astrophysics Data System (ADS)
Gjesteby, Lars; Cong, Wenxiang; Wang, Ge
2017-09-01
Multi-modality imaging methods are instrumental for advanced diagnosis and therapy. Specifically, a hybrid system that combines computed tomography (CT), nuclear imaging, and magnetic resonance imaging (MRI) will be a Holy Grail of medical imaging, delivering complementary structural/morphological, functional, and molecular information for precision medicine. A novel imaging method was recently demonstrated that takes advantage of radiotracer polarization to combine MRI principles with nuclear imaging. This approach allows the concentration of a polarized Υ-ray emitting radioisotope to be imaged with MRI resolution potentially outperforming the standard nuclear imaging mode at a sensitivity significantly higher than that of MRI. In our work, we propose to acquire MRI-modulated nuclear data for simultaneous image reconstruction of both emission and transmission parameters, suggesting the potential for simultaneous CT-SPECT-MRI. The synchronized diverse datasets allow excellent spatiotemporal registration and unique insight into physiological and pathological features. Here we describe the methodology involving the system design with emphasis on the formulation for tomographic images, even when significant radiotracer signals are limited to a region of interest (ROI). Initial numerical results demonstrate the feasibility of our approach for reconstructing concentration and attenuation images through a head phantom with various radio-labeled ROIs. Additional considerations regarding the radioisotope characteristics are also discussed.
Single photon emission computed tomography-guided Cerenkov luminescence tomography
NASA Astrophysics Data System (ADS)
Hu, Zhenhua; Chen, Xueli; Liang, Jimin; Qu, Xiaochao; Chen, Duofang; Yang, Weidong; Wang, Jing; Cao, Feng; Tian, Jie
2012-07-01
Cerenkov luminescence tomography (CLT) has become a valuable tool for preclinical imaging because of its ability of reconstructing the three-dimensional distribution and activity of the radiopharmaceuticals. However, it is still far from a mature technology and suffers from relatively low spatial resolution due to the ill-posed inverse problem for the tomographic reconstruction. In this paper, we presented a single photon emission computed tomography (SPECT)-guided reconstruction method for CLT, in which a priori information of the permissible source region (PSR) from SPECT imaging results was incorporated to effectively reduce the ill-posedness of the inverse reconstruction problem. The performance of the method was first validated with the experimental reconstruction of an adult athymic nude mouse implanted with a Na131I radioactive source and an adult athymic nude mouse received an intravenous tail injection of Na131I. A tissue-mimic phantom based experiment was then conducted to illustrate the ability of the proposed method in resolving double sources. Compared with the traditional PSR strategy in which the PSR was determined by the surface flux distribution, the proposed method obtained much more accurate and encouraging localization and resolution results. Preliminary results showed that the proposed SPECT-guided reconstruction method was insensitive to the regularization methods and ignored the heterogeneity of tissues which can avoid the segmentation procedure of the organs.
Using artificial neural networks (ANN) for open-loop tomography
NASA Astrophysics Data System (ADS)
Osborn, James; De Cos Juez, Francisco Javier; Guzman, Dani; Butterley, Timothy; Myers, Richard; Guesalaga, Andres; Laine, Jesus
2011-09-01
The next generation of adaptive optics (AO) systems require tomographic techniques in order to correct for atmospheric turbulence along lines of sight separated from the guide stars. Multi-object adaptive optics (MOAO) is one such technique. Here, we present a method which uses an artificial neural network (ANN) to reconstruct the target phase given off-axis references sources. This method does not require any input of the turbulence profile and is therefore less susceptible to changing conditions than some existing methods. We compare our ANN method with a standard least squares type matrix multiplication method (MVM) in simulation and find that the tomographic error is similar to the MVM method. In changing conditions the tomographic error increases for MVM but remains constant with the ANN model and no large matrix inversions are required.
NASA Astrophysics Data System (ADS)
Massambone de Oliveira, Rafael; Salomão Helou, Elias; Fontoura Costa, Eduardo
2016-11-01
We present a method for non-smooth convex minimization which is based on subgradient directions and string-averaging techniques. In this approach, the set of available data is split into sequences (strings) and a given iterate is processed independently along each string, possibly in parallel, by an incremental subgradient method (ISM). The end-points of all strings are averaged to form the next iterate. The method is useful to solve sparse and large-scale non-smooth convex optimization problems, such as those arising in tomographic imaging. A convergence analysis is provided under realistic, standard conditions. Numerical tests are performed in a tomographic image reconstruction application, showing good performance for the convergence speed when measured as the decrease ratio of the objective function, in comparison to classical ISM.
Vemmer, T; Steinbüchel, C; Bertram, J; Eschner, W; Kögler, A; Luig, H
1997-03-01
The purpose of this study was to determine whether data acquisition in the list mode and iterative tomographic reconstruction would render feasible cardiac phase-synchronized thallium-201 single-photon emission tomography (SPET) of the myocardium under routine conditions without modifications in tracer dose, acquisition time, or number of steps of the a gamma camera. Seventy non-selected patients underwent 201T1 SPET imaging according to a routine protocol (74 MBq/2 mCi 201T1, 180 degrees rotation of the gamma camera, 32 steps, 30 min). Gamma camera data, ECG, and a time signal were recorded in list mode. The cardiac cycle was divided into eight phases, the end-diastolic phase encompassing the QRS complex, and the end-systolic phase the T wave. Both phase- and non-phase-synchronized tomograms based on the same list mode data were reconstructed iteratively. Phase-synchronized and non-synchronized images were compared. Patients were divided into two groups depending on whether or not coronary artery disease had been definitely diagnosed prior to SPET imaging. The numbers of patients in both groups demonstrating defects visible on the phase-synchronized but not on the non-synchronized images were compared. It was found that both postexercise and redistribution phase tomograms were suited for interpretation. The changes from end-diastolic to end-systolic images allowed a comparative assessment of regional wall motility and tracer uptake. End-diastolic tomograms provided the best definition of defects. Additional defects not apparent on non-synchronized images were visible in 40 patients, six of whom did not show any defect on the non-synchronized images. Of 42 patients in whom coronary artery disease had been definitely diagnosed, 19 had additional defects not visible on the non-synchronized images, in comparison to 21 of 28 in whom coronary artery disease was suspected (P < 0.02; chi 2). It is concluded that cardiac phase-synchronized 201T1 SPET of the myocardium was made feasible by list mode data acquisition and iterative reconstruction. The additional findings on the phase-synchronized tomograms, not visible on the non-synchronized ones, represented genuine defects. Cardiac phase-synchronized 201T1 SPET is advantageous in allowing simultaneous assessment of regional wall motion and tracer uptake, and in visualizing smaller defects.
NASA Astrophysics Data System (ADS)
Lanusse, F.; Rassat, A.; Starck, J.-L.
2015-06-01
Context. Upcoming spectroscopic galaxy surveys are extremely promising to help in addressing the major challenges of cosmology, in particular in understanding the nature of the dark universe. The strength of these surveys, naturally described in spherical geometry, comes from their unprecedented depth and width, but an optimal extraction of their three-dimensional information is of utmost importance to best constrain the properties of the dark universe. Aims: Although there is theoretical motivation and novel tools to explore these surveys using the 3D spherical Fourier-Bessel (SFB) power spectrum of galaxy number counts Cℓ(k,k'), most survey optimisations and forecasts are based on the tomographic spherical harmonics power spectrum C(ij)_ℓ. The goal of this paper is to perform a new investigation of the information that can be extracted from these two analyses in the context of planned stage IV wide-field galaxy surveys. Methods: We compared tomographic and 3D SFB techniques by comparing the forecast cosmological parameter constraints obtained from a Fisher analysis. The comparison was made possible by careful and coherent treatment of non-linear scales in the two analyses, which makes this study the first to compare 3D SFB and tomographic constraints on an equal footing. Nuisance parameters related to a scale- and redshift-dependent galaxy bias were also included in the computation of the 3D SFB and tomographic power spectra for the first time. Results: Tomographic and 3D SFB methods can recover similar constraints in the absence of systematics. This requires choosing an optimal number of redshift bins for the tomographic analysis, which we computed to be N = 26 for zmed ≃ 0.4, N = 30 for zmed ≃ 1.0, and N = 42 for zmed ≃ 1.7. When marginalising over nuisance parameters related to the galaxy bias, the forecast 3D SFB constraints are less affected by this source of systematics than the tomographic constraints. In addition, the rate of increase of the figure of merit as a function of median redshift is higher for the 3D SFB method than for the 2D tomographic method. Conclusions: Constraints from the 3D SFB analysis are less sensitive to unavoidable systematics stemming from a redshift- and scale-dependent galaxy bias. Even for surveys that are optimised with tomography in mind, a 3D SFB analysis is more powerful. In addition, for survey optimisation, the figure of merit for the 3D SFB method increases more rapidly with redshift, especially at higher redshifts, suggesting that the 3D SFB method should be preferred for designing and analysing future wide-field spectroscopic surveys. CosmicPy, the Python package developed for this paper, is freely available at https://cosmicpy.github.io. Appendices are available in electronic form at http://www.aanda.org
NASA Astrophysics Data System (ADS)
Youssof, Mohammad; Yuan, Xiaohui; Tilmann, Frederik; Heit, Benjamin; Weber, Michael; Jokat, Wilfried; Geissler, Wolfram; Laske, Gabi; Eken, Tuna; Lushetile, Bufelo
2015-04-01
We present a 3D high-resolution seismic model of the southwestern Africa region from teleseismic tomographic inversion of the P- and S- wave data recorded by the amphibious WALPASS network. We used 40 temporary stations in southwestern Africa with records for a period of 2 years (the OBS operated for 1 year), between November 2010 and November 2012. The array covers a surface area of approximately 600 by 1200 km and is located at the intersection of the Walvis Ridge, the continental margin of northern Namibia, and extends into the Congo craton. Major questions that need to be understood are related to the impact of asthenosphere-lithosphere interaction, (plume-related features), on the continental areas and the evolution of the continent-ocean transition that followed the break-up of Gondwana. This process is supposed to leave its imprint as distinct seismic signature in the upper mantle. Utilizing 3D sensitivity kernels, we invert traveltime residuals to image velocity perturbations in the upper mantle down to 1000 km depth. To test the robustness of our tomographic image we employed various resolution tests which allow us to evaluate the extent of smearing effects and help defining the optimum inversion parameters (i.e., damping and smoothness) used during the regularization of inversion process. Resolution assessment procedure includes also a detailed investigation of the effect of the crustal corrections on the final images, which strongly influenced the resolution for the mantle structures. We present detailed tomographic images of the oceanic and continental lithosphere beneath the study area. The fast lithospheric keel of the Congo Craton reaches a depth of ~250 km. Relatively low velocity perturbations have been imaged within the orogenic Damara Belt down to a depth of ~150 km, probably related to surficial suture zones and the presence of fertile material. A shallower depth extent of the lithospheric plate of ~100 km was observed beneath the ocean, consistent with plate-cooling models. In addition to tomographic images, the seismic anisotropy measurements within the upper mantle inferred from teleseismic shear waves indicate a predominant NE-SW orientation for most of the land stations. Current results indicate no evidence for a consistent signature of fossil plume.
40 CFR 60.1740 - What is my schedule for evaluating continuous emission monitoring systems?
Code of Federal Regulations, 2011 CFR
2011-07-01
... continuous emission monitoring systems? 60.1740 Section 60.1740 Protection of Environment ENVIRONMENTAL... evaluating continuous emission monitoring systems? (a) Conduct annual evaluations of your continuous emission monitoring systems no more than 13 months after the previous evaluation was conducted. (b) Evaluate your...
40 CFR 62.15195 - What is my schedule for evaluating continuous emission monitoring systems?
Code of Federal Regulations, 2010 CFR
2010-07-01
... continuous emission monitoring systems? 62.15195 Section 62.15195 Protection of Environment ENVIRONMENTAL... evaluating continuous emission monitoring systems? (a) Conduct annual evaluations of your continuous emission monitoring systems no more than 13 months after the previous evaluation was conducted. (b) Evaluate your...
40 CFR 62.15195 - What is my schedule for evaluating continuous emission monitoring systems?
Code of Federal Regulations, 2011 CFR
2011-07-01
... continuous emission monitoring systems? 62.15195 Section 62.15195 Protection of Environment ENVIRONMENTAL... evaluating continuous emission monitoring systems? (a) Conduct annual evaluations of your continuous emission monitoring systems no more than 13 months after the previous evaluation was conducted. (b) Evaluate your...
Fan, Qiyong; Nanduri, Akshay; Yang, Jaewon; Yamamoto, Tokihiro; Loo, Billy; Graves, Edward; Zhu, Lei; Mazin, Samuel
2013-01-01
Purpose: Emission guided radiation therapy (EGRT) is a new modality that uses PET emissions in real-time for direct tumor tracking during radiation delivery. Radiation beamlets are delivered along positron emission tomography (PET) lines of response (LORs) by a fast rotating ring therapy unit consisting of a linear accelerator (Linac) and PET detectors. The feasibility of tumor tracking and a primitive modulation method to compensate for attenuation have been demonstrated using a 4D digital phantom in our prior work. However, the essential capability of achieving dose modulation as in conventional intensity modulated radiation therapy (IMRT) treatments remains absent. In this work, the authors develop a planning scheme for EGRT to accomplish sophisticated intensity modulation based on an IMRT plan while preserving tumor tracking. Methods: The planning scheme utilizes a precomputed LOR response probability distribution to achieve desired IMRT planning modulation with effects of inhomogeneous attenuation and nonuniform background activity distribution accounted for. Evaluation studies are performed on a 4D digital patient with a simulated lung tumor and a clinical patient who has a moving breast cancer metastasis in the lung. The Linac dose delivery is simulated using a voxel-based Monte Carlo algorithm. The IMRT plan is optimized for a planning target volume (PTV) that encompasses the tumor motion using the MOSEK package and a Pinnacle3™ workstation (Philips Healthcare, Fitchburg, WI) for digital and clinical patients, respectively. To obtain the emission data for both patients, the Geant4 application for tomographic emission (GATE) package and a commercial PET scanner are used. As a comparison, 3D and helical IMRT treatments covering the same PTV based on the same IMRT plan are simulated. Results: 3D and helical IMRT treatments show similar dose distribution. In the digital patient case, compared with the 3D IMRT treatment, EGRT achieves a 15.1% relative increase in dose to 95% of the gross tumor volume (GTV) and a 31.8% increase to 50% of the GTV. In the patient case, EGRT yields a 15.2% relative increase in dose to 95% of the GTV and a 20.7% increase to 50% of the GTV. The organs at risk (OARs) doses are kept similar or lower for EGRT in both cases. Tumor tracking is observed in the presence of planning modulation in all EGRT treatments. Conclusions: As compared to conventional IMRT treatments, the proposed EGRT planning scheme allows an escalated target dose while keeping dose to the OARs within the same planning limits. With the capabilities of incorporating planning modulation and accurate tumor tracking, EGRT has the potential to greatly improve targeting in radiation therapy and enable a practical and effective implementation of 4D radiation therapy for planning and delivery. PMID:23927305
Tomographic Image Reconstruction Using an Interpolation Method for Tree Decay Detection
Hailin Feng; Guanghui Li; Sheng Fu; Xiping Wang
2014-01-01
Stress wave velocity has been traditionally regarded as an indicator of the extent of damage inside wood. This paper aimed to detect internal decay of urban trees through reconstructing tomographic image of the cross section of a tree trunk. A grid model covering the cross section area of a tree trunk was defined with some assumptions. Stress wave data were processed...
Banzato, Tommaso; Russo, Elisa; Di Toma, Anna; Palmisano, Giuseppe; Zotti, Alessandro
2011-12-01
To evaluate the radiographic, computed tomographic (CT), and cadaveric anatomy of the head of boa constrictors. 4 Boa constrictor imperator cadavers. Cadavers weighed 3.4 to 5.6 kg and had a body length ranging from 189 to 221 cm. Radiographic and CT images were obtained with a high-detail screen-film combination, and conventional CT was performed with a slice thickness of 1.5 mm. Radiographic images were obtained in ventrodorsal, dorsoventral, and left and right laterolateral recumbency; CT images were obtained with the animals positioned in ventral recumbency directly laying on a plastic support. At the end of the radiographic and CT imaging session, 2 heads were sectioned following a stratigraphic approach; the other 2, carefully maintained in the same position on the plastic support, were moved into a freezer (-20°C) until completely frozen and then sectioned into 3-mm slices, respecting the imaging protocol. The frozen sections were cleaned and then photographed on each side. Anatomic structures were identified and labeled on gross anatomic images and on the corresponding CT or radiographic image with the aid of available literature. Radiographic and CT images provided high detail for visualization of bony structures; soft tissues were not easily identified on radiographic and CT images. Results provide an atlas of stratigraphic and cross-sectional gross anatomy and radiographic and CT anatomy of the heads of boa constrictors that might be useful in the interpretation of any imaging modality in this species.
Ho, Allen L; Lin, Ning; Frerichs, Kai U; Du, Rose
2015-09-01
As diagnosis and treatment of unruptured intracranial aneurysms continues to increase, management principles remain largely based on size. This is despite mounting evidence that aneurysm location and other morphologic variables could play a role in predicting overall risk of rupture. Morphological parameters can be divided into 3 main groups, those that are intrinsic to the aneurysm, those that are extrinsic to the aneurysm, and those that involve both the aneurysm and surrounding vasculature (transitional). We present an evaluation of intrinsic, transitional, and extrinsic factors and their association with ruptured aneurysms. Using preoperative computed tomographic angiography, we generated 3-dimensional models of aneurysms and their surrounding vasculature with Slicer software. Using univariate and multivariate analyses, we examined the association of intrinsic, transitional, and extrinsic aspects of aneurysm morphology with rupture. Between 2005 and 2013, 227 cerebral aneurysms in 4 locations were evaluated/treated at a single institution, and computed tomographic angiographies of 218 patients (97 unruptured and 130 ruptured) were analyzed. Ruptured aneurysms analyzed were associated with clinical factors of absence of multiple aneurysms and history of no prior rupture, and morphologic factors of greater aspect ratio. On multivariate analysis, aneurysm rupture remained associated with history of no prior rupture, greater flow angle, greater daughter-daughter vessel angle, and smaller parent-daughter vessel angle. By studying the morphology of aneurysms and their surrounding vasculature, we identified several parameters associated with ruptured aneurysms that include intrinsic, transitional, and extrinsic factors of cerebral aneurysms and their surrounding vasculature.
Detection of Apical Root Cracks Using Spectral Domain and Swept-source Optical Coherence Tomography.
de Oliveira, Bruna Paloma; Câmara, Andréa Cruz; Duarte, Daniel Amancio; Gomes, Anderson Stevens Leonidas; Heck, Richard John; Antonino, Antonio Celso Dantas; Aguiar, Carlos Menezes
2017-07-01
This study aimed to evaluate the ability of 2 optical coherence tomographic (OCT) systems to detect apical dentinal microcracks. Twenty extracted human single-rooted mandibular incisors were selected. After root canal preparation with an R40 Reciproc file (VDW, Munich, Germany), the specimens presenting apical microcracks were identified using micro-computed tomographic (micro-CT) scanning as the gold standard. Then, the apical portions of the roots were imaged with spectral domain OCT (SD-OCT) and swept-source OCT systems, and the resulting images were blindly evaluated by 3 independent examiners to detect microcracks. The diagnostic performance of each OCT device was calculated, and statistical analysis was performed. Based on the micro-CT images, 12 (60%) roots presented dentinal microcracks in the apical region. The images generated by the OCT systems were able to show microcrack lines at the same location as the corresponding micro-CT cross sections. Although the diagnostic performance of the SD-OCT device was superior, there were no statistically significant differences between the 2 OCT devices (P > .05). Interexaminer agreement was substantial to almost perfect for the SD-OCT system and moderate to almost perfect for the swept-source OCT system, whereas intraexaminer agreement was substantial to almost perfect for both OCT devices. The detection ability verified for both OCT systems renders them promising tools for the diagnosis of apical microcracks. Copyright © 2017 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Martin, Ralph J; Santiago, Bartolo
2015-09-01
Left ventricular (LV) function parameters have major diagnostic and prognostic importance in heart disease. Measurement of ventricular function with tomographic (SPECT) radionuclide ventriculography (MUGA) decreases camera time, improves contrast resolution, accuracy of interpretation and the overall reliability of the study as compared to planar MUGA. The relationship between these techniques is well established particularly with LV ejection fraction (LVEF), while there is limited data comparing the diastolic function parameters. Our goal was to validate the LV function parameters in our Hispanic population. Studies from 44 patients, available from 2009-2010, were retrospectively evaluated. LVEF showed a good correlation between the techniques (r=0.94) with an average difference of 3.8%. In terms of categorizing the results as normal or abnormal, this remained unchanged in 95% of the cases (p=0.035). For the peak filling rate, there was a moderate correlation between the techniques (r=0.71), whereas the diagnosis remained unchanged in 89% of cases (p=0.0004). Time to peak filling values only demonstrated a weak correlation (r=0.22). Nevertheless, the diagnosis remained the same in 68% of the cases (p=0.089). Systolic function results in our study were well below the 7-10% difference reported in the literature. Only a weak to moderate correlation was observed with the diastolic function parameters. Comparison with echocardiogram (not available) may be of benefit to evaluate which of these techniques results in more accurate diastolic function parameters.
Rakhmatia, Yunia Dwi; Ayukawa, Yasunori; Furuhashi, Akihiro; Koyano, Kiyoshi
2014-01-01
The objective of this study was to evaluate the optimal thickness and porosity of novel titanium mesh membranes to enhance bone augmentation, prevent soft tissue ingrowth, and prevent membrane exposure. Six types of novel titanium meshes with different thicknesses and pore sizes, along with three commercially available membranes, were used to cover surgically created calvarial defects in 6-week-old Sprague-Dawley rats. The animals were killed after 4 or 8 weeks. Microcomputed tomographic analyses were performed to analyze the three-dimensional bone volume and bone mineral density. Soft tissue ingrowth was also evaluated histologically and histomorphometrically. The novel titanium membranes used in this study were as effective at augmenting bone in the rat calvarial defect model as the commercially available membranes. The greatest bone volume was observed on 100-μm-thick membranes with larger pores, although these membranes promoted growth of bone with lower mineral density. Soft tissue ingrowth when 100-μm membranes were used was increased at 4 weeks but decreased again by 8 weeks to a level not statistically significantly different from other membranes. Membrane thickness affects the total amount of new bone formation, and membrane porosity is an essential factor for guided bone regeneration, especially during the initial healing period, although the final bone volume obtained is essentially the same. Newly developed titanium mesh membranes of 100 μm in thickness and with large pores appear to be optimal for guided bone regeneration.
Sporns, Peter B; Schwake, Michael; Schmidt, Rene; Kemmling, André; Minnerup, Jens; Schwindt, Wolfram; Cnyrim, Christian; Zoubi, Tarek; Heindel, Walter; Niederstadt, Thomas; Hanning, Uta
2017-01-01
Significant early hematoma growth in patients with intracerebral hemorrhage is an independent predictor of poor functional outcome. Recently, the novel blend sign (BS) has been introduced as a new imaging sign for predicting hematoma growth in noncontrast computed tomography. Another parameter predicting increasing hematoma size is the well-established spot sign (SS) visible in computed tomographic angiography. We, therefore, aimed to clarify the association between established SS and novel BS and their values predicting a secondary neurological deterioration. Retrospective study inclusion criteria were (1) spontaneous intracerebral hemorrhage confirmed on noncontrast computed tomography and (2) noncontrast computed tomography and computed tomographic angiography performed on admission within 6 hours after onset of symptoms. We defined a binary outcome (secondary neurological deterioration versus no secondary deterioration). As secondary neurological deterioration, we defined (1) early hemicraniectomy under standardized criteria or (2) secondary decrease of Glasgow Coma Scale of >3 points, both within the first 48 hours after symptom onset. Of 182 patients with spontaneous intracerebral hemorrhage, 37 (20.3%) presented with BS and 39 (21.4%) with SS. Of the 81 patients with secondary deterioration, 31 (38.3%) had BS and SS on admission. Multivariable logistic regression analysis identified hematoma volume (odds ratio, 1.07 per mL; P≤0.001), intraventricular hemorrhage (odds ratio, 3.08; P=0.008), and the presence of BS (odds ratio, 11.47; P≤0.001) as independent predictors of neurological deterioration. The BS, which is obtainable in noncontrast computed tomography, shows a high correlation with the computed tomographic angiography SS and is a reliable predictor of secondary neurological deterioration after spontaneous intracerebral hemorrhage. © 2016 American Heart Association, Inc.
NASA Astrophysics Data System (ADS)
Moeck, Jonas P.; Bourgouin, Jean-François; Durox, Daniel; Schuller, Thierry; Candel, Sébastien
2013-04-01
Swirl flows with vortex breakdown are widely used in industrial combustion systems for flame stabilization. This type of flow is known to sustain a hydrodynamic instability with a rotating helical structure, one common manifestation of it being the precessing vortex core. The role of this unsteady flow mode in combustion is not well understood, and its interaction with combustion instabilities and flame stabilization remains unclear. It is therefore important to assess the structure of the perturbation in the flame that is induced by this helical mode. Based on principles of tomographic reconstruction, a method is presented to determine the 3-D distribution of the heat release rate perturbation associated with the helical mode. Since this flow instability is rotating, a phase-resolved sequence of projection images of light emitted from the flame is identical to the Radon transform of the light intensity distribution in the combustor volume and thus can be used for tomographic reconstruction. This is achieved with one stationary camera only, a vast reduction in experimental and hardware requirements compared to a multi-camera setup or camera repositioning, which is typically required for tomographic reconstruction. Different approaches to extract the coherent part of the oscillation from the images are discussed. Two novel tomographic reconstruction algorithms specifically tailored to the structure of the heat release rate perturbations related to the helical mode are derived. The reconstruction techniques are first applied to an artificial field to illustrate the accuracy. High-speed imaging data acquired in a turbulent swirl-stabilized combustor setup with strong helical mode oscillations are then used to reconstruct the 3-D structure of the associated perturbation in the flame.
Li, Qiao; Gao, Xinyi; Yao, Zhenwei; Feng, Xiaoyuan; He, Huijin; Xue, Jing; Gao, Peiyi; Yang, Lumeng; Cheng, Xin; Chen, Weijian; Yang, Yunjun
2017-09-01
Permeability surface (PS) on computed tomographic perfusion reflects blood-brain barrier permeability and is related to hemorrhagic transformation (HT). HT of deep middle cerebral artery (MCA) territory can occur after recanalization of proximal large-vessel occlusion. We aimed to determine the relationship between HT and PS of deep MCA territory. We retrospectively reviewed 70 consecutive acute ischemic stroke patients presenting with occlusion of the distal internal carotid artery or M1 segment of the MCA. All patients underwent computed tomographic perfusion within 6 hours after symptom onset. Computed tomographic perfusion data were postprocessed to generate maps of different perfusion parameters. Risk factors were identified for increased deep MCA territory PS. Receiver operating characteristic curve analysis was performed to calculate the optimal PS threshold to predict HT of deep MCA territory. Increased PS was associated with HT of deep MCA territory. After adjustments for age, sex, onset time to computed tomographic perfusion, and baseline National Institutes of Health Stroke Scale, poor collateral status (odds ratio, 7.8; 95% confidence interval, 1.67-37.14; P =0.009) and proximal MCA-M1 occlusion (odds ratio, 4.12; 95% confidence interval, 1.03-16.52; P =0.045) were independently associated with increased deep MCA territory PS. Relative PS most accurately predicted HT of deep MCA territory (area under curve, 0.94; optimal threshold, 2.89). Increased PS can predict HT of deep MCA territory after recanalization therapy for cerebral proximal large-vessel occlusion. Proximal MCA-M1 complete occlusion and distal internal carotid artery occlusion in conjunction with poor collaterals elevate deep MCA territory PS. © 2017 American Heart Association, Inc.
High-Resolution CT and Angiographic Evaluation of NexStent Wall Adaptation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nemes, Balazs, E-mail: nembal@freemail.hu; Lukacs, Levente; Balazs, Gyoergy
2009-05-15
Carotid stenting is a minimally invasive treatment for extracranial carotid artery stenosis. Stent design may affect technical success and complications in a certain subgroup of patients. We examined the wall adaptability of a new closed-cell carotid stent (NexStent), which has a unique rolled sheet design. Forty-one patients had 42 carotid arteries treated with angioplasty and stenting for internal carotid artery stenosis. The mean patient age was 65 {+-} 10 years. All patients underwent high-resolution computed tomographic angiography after the stent implantation. Data analysis included pre- and postprocedural stenosis, procedure complications, plaque calcification, and stent apposition. We reviewed the angiographic andmore » computed tomographic images for plaque coverage and stent expansion. All procedures were technically successful. Mean stenosis was reduced from 84 {+-} 8% before the procedure to 15.7 {+-} 7% after stenting. Two patients experienced transient ischemic attack; one patient had bradycardia and hypotension. Stent induced kinking was observed in one case. Good plaque coverage and proper overlapping of the rolled sheet was achieved in all cases. There was weak correlation between the residual stenosis and the amount of calcification. The stent provides adequate expansion and adaptation to the tapering anatomy of the bifurcation.« less
Multislice spiral CT simulator for dynamic cardiopulmonary studies
NASA Astrophysics Data System (ADS)
De Francesco, Silvia; Ferreira da Silva, Augusto M.
2002-04-01
We've developed a Multi-slice Spiral CT Simulator modeling the acquisition process of a real tomograph over a 4-dimensional phantom (4D MCAT) of the human thorax. The simulator allows us to visually characterize artifacts due to insufficient temporal sampling and a priori evaluate the quality of the images obtained in cardio-pulmonary studies (both with single-/multi-slice and ECG gated acquisition processes). The simulating environment allows both for conventional and spiral scanning modes and includes a model of noise in the acquisition process. In case of spiral scanning, reconstruction facilities include longitudinal interpolation methods (360LI and 180LI both for single and multi-slice). Then, the reconstruction of the section is performed through FBP. The reconstructed images/volumes are affected by distortion due to insufficient temporal sampling of the moving object. The developed simulating environment allows us to investigate the nature of the distortion characterizing it qualitatively and quantitatively (using, for example, Herman's measures). Much of our work is focused on the determination of adequate temporal sampling and sinogram regularization techniques. At the moment, the simulator model is limited to the case of multi-slice tomograph, being planned as a next step of development the extension to cone beam or area detectors.
Evaluation Experiment of Ultrasound Computed Tomography for the Abdominal Sound Speed Imaging
NASA Astrophysics Data System (ADS)
Nogami, Keisuke; Yamada, Akira
2007-07-01
Abdominal sound speed tomographic imaging using through-transmission travel time data on the body surface was investigated. To this end, a hundred kHz range low-frequency wave was used to reduce the wave attenuation within an inner body medium. A method was investigated for the reconstruction of the image with the smallest possible number of path data around the abdominal surface. Specifically, the data from a strong scattering spinal cord should be avoided. To fulfill the requirement, the smoothed path algebraic reconstruction technique was introduced. The validity of this method was examined both on the numerically synthesized data and the experimentally measured data for the phantom specimen and actual human subject. It was shown that an abdominal tomographic sound speed image could be successfully obtained by preparing only 32 transducer locations at the circumference around the abdominal surface and their combination of less than 100 number of observation path data as well as by avoiding the data intersecting the spinal cord. In addition, fat regions were extracted having a sound speed lower than the threshold value to demonstrate the possibility of this method for metabolic syndrome diagnosis.
NASA Astrophysics Data System (ADS)
Xuan, Li; He, Bin; Hu, Li-Fa; Li, Da-Yu; Xu, Huan-Yu; Zhang, Xing-Yun; Wang, Shao-Xin; Wang, Yu-Kun; Yang, Cheng-Liang; Cao, Zhao-Liang; Mu, Quan-Quan; Lu, Xing-Hai
2016-09-01
Multi-conjugation adaptive optics (MCAOs) have been investigated and used in the large aperture optical telescopes for high-resolution imaging with large field of view (FOV). The atmospheric tomographic phase reconstruction and projection of three-dimensional turbulence volume onto wavefront correctors, such as deformable mirrors (DMs) or liquid crystal wavefront correctors (LCWCs), is a very important step in the data processing of an MCAO’s controller. In this paper, a method according to the wavefront reconstruction performance of MCAO is presented to evaluate the optimized configuration of multi laser guide stars (LGSs) and the reasonable conjugation heights of LCWCs. Analytical formulations are derived for the different configurations and are used to generate optimized parameters for MCAO. Several examples are given to demonstrate our LGSs configuration optimization method. Compared with traditional methods, our method has minimum wavefront tomographic error, which will be helpful to get higher imaging resolution at large FOV in MCAO. Project supported by the National Natural Science Foundation of China (Grant Nos. 11174274, 11174279, 61205021, 11204299, 61475152, and 61405194) and the State Key Laboratory of Applied Optics, Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences.
Clinical studies of pigmented lesions in human skin by using a multiphoton tomograph
NASA Astrophysics Data System (ADS)
Balu, Mihaela; Kelly, Kristen M.; Zachary, Christopher B.; Harris, Ronald M.; Krasieva, Tatiana B.; König, Karsten; Tromberg, Bruce J.
2013-02-01
In vivo imaging of pigmented lesions in human skin was performed with a clinical multiphoton microscopy (MPM)-based tomograph (MPTflex, JenLab, Germany). Two-photon excited fluorescence was used for visualizing endogenous fluorophores such as NADH/FAD, keratin, melanin in the epidermal cells and elastin fibers in the dermis. Collagen fibers were imaged by second harmonic generation. Our study involved in vivo imaging of benign melanocytic nevi, atypical nevi and melanoma. The goal of this preliminary study was to identify in vivo the characteristic features and their frequency in pigmented lesions at different stages (benign, atypical and malignant) and to evaluate the ability of in vivo MPM to distinguish atypical nevi from melanoma. Comparison with histopathology was performed for the biopsied lesions. Benign melanocytic nevi were characterized by the presence of nevus cell nests at the epidermal-dermal junction. In atypical nevi, features such as lentiginous hyperplasia, acanthosis and architectural disorder were imaged. Cytological atypia was present in all the melanoma lesions imaged, showing the strongest correlation with malignancy. The MPM images demonstrated very good correlation with corresponding histological images, suggesting that MPM could be a promising tool for in vivo non-invasive pigmented lesion diagnosis, particularly distinguishing atypical nevi from melanoma.
NASA Astrophysics Data System (ADS)
Sun, G.; Moncelsi, L.; Viero, M. P.; Silva, M. B.; Bock, J.; Bradford, C. M.; Chang, T.-C.; Cheng, Y.-T.; Cooray, A. R.; Crites, A.; Hailey-Dunsheath, S.; Uzgil, B.; Hunacek, J. R.; Zemcov, M.
2018-04-01
Intensity mapping provides a unique means to probe the epoch of reionization (EoR), when the neutral intergalactic medium was ionized by energetic photons emitted from the first galaxies. The [C II] 158 μm fine-structure line is typically one of the brightest emission lines of star-forming galaxies and thus a promising tracer of the global EoR star formation activity. However, [C II] intensity maps at 6 ≲ z ≲ 8 are contaminated by interloping CO rotational line emission (3 ≤ J upp ≤ 6) from lower-redshift galaxies. Here we present a strategy to remove the foreground contamination in upcoming [C II] intensity mapping experiments, guided by a model of CO emission from foreground galaxies. The model is based on empirical measurements of the mean and scatter of the total infrared luminosities of galaxies at z < 3 and with stellar masses {M}* > {10}8 {M}ȯ selected in the K-band from the COSMOS/UltraVISTA survey, which can be converted to CO line strengths. For a mock field of the Tomographic Ionized-carbon Mapping Experiment, we find that masking out the “voxels” (spectral–spatial elements) containing foreground galaxies identified using an optimized CO flux threshold results in a z-dependent criterion {m}{{K}}AB}≲ 22 (or {M}* ≳ {10}9 {M}ȯ ) at z < 1 and makes a [C II]/COtot power ratio of ≳10 at k = 0.1 h/Mpc achievable, at the cost of a moderate ≲8% loss of total survey volume.
NASA Astrophysics Data System (ADS)
Di Pietra, V.; Donadio, E.; Picchi, D.; Sambuelli, L.; Spanò, A.
2017-02-01
The paper presents the workflow and the results of an ultrasonic 3D investigation and a 3D survey application aimed at the assessment of the internal integrity of an ancient sculpture. The work aimed at highlighting the ability of methods devoted to the 3D geometry acquisition of small objects when applied to diagnosis performed by geophysical investigation. In particular, two methods widely applied for small objects modelling are considered and compared, the digital Photogrammetry with the Structure from Motion (SFM) technique and hand-held 3D scanners. The study concludes with the aim to enhance the final graphical representation of the tomographic results and to subject the obtained results to a quantitative analysis. The survey is applied to the Egyptian naophorous statue of Amenmes and Reshpu, which dates to the reign of Ramses II (1279-1213 BC) or later and is now preserved in the Civic Archaeological Museum in Bologna. In order to evaluate the internal persistency of fractures and visible damages, a 3D Ultrasonic Tomographic Imaging (UTI) test has been performed and a multi-sensor survey (image and range based) was conducted, in order to evaluate the locations of the source and receiver points as accurate as possible The presented test allowed to evaluate the material characteristics, its porosity and degradation state, which particularly affect the lower part of the statue. More in general, the project demonstrated how solution coming from the field of 3D modelling of Cultural Heritage allow the application of 3D ultrasonic tomography also on objects with complex shapes, in addition to the improved representation of the obtained results.
Chow, Benjamin J W; Freeman, Michael R; Bowen, James M; Levin, Leslie; Hopkins, Robert B; Provost, Yves; Tarride, Jean-Eric; Dennie, Carole; Cohen, Eric A; Marcuzzi, Dan; Iwanochko, Robert; Moody, Alan R; Paul, Narinder; Parker, John D; O'Reilly, Daria J; Xie, Feng; Goeree, Ron
2011-06-13
Computed tomographic coronary angiography (CTCA) has gained clinical acceptance for the detection of obstructive coronary artery disease. Although single-center studies have demonstrated excellent accuracy, multicenter studies have yielded variable results. The true diagnostic accuracy of CTCA in the "real world" remains uncertain. We conducted a field evaluation comparing multidetector CTCA with invasive CA (ICA) to understand CTCA's diagnostic accuracy in a real-world setting. A multicenter cohort study of patients awaiting ICA was conducted between September 2006 and June 2009. All patients had either a low or an intermediate pretest probability for coronary artery disease and underwent CTCA and ICA within 10 days. The results of CTCA and ICA were interpreted visually by local expert observers who were blinded to all clinical data and imaging results. Using a patient-based analysis (diameter stenosis ≥50%) of 169 patients, the sensitivity, specificity, positive predictive value, and negative predictive value were 81.3% (95% confidence interval [CI], 71.0%-89.1%), 93.3% (95% CI, 85.9%-97.5%), 91.6% (95% CI, 82.5%-96.8%), and 84.7% (95% CI, 76.0%-91.2%), respectively; the area under receiver operating characteristic curve was 0.873. The diagnostic accuracy varied across centers (P < .001), with a sensitivity, specificity, positive predictive value, and negative predictive value ranging from 50.0% to 93.2%, 92.0% to 100%, 84.6% to 100%, and 42.9% to 94.7%, respectively. Compared with ICA, CTCA appears to have good accuracy; however, there was variability in diagnostic accuracy across centers. Factors affecting institutional variability need to be better understood before CTCA is universally adopted. Additional real-world evaluations are needed to fully understand the impact of CTCA on clinical care. clinicaltrials.gov Identifier: NCT00371891.
Bornstein, Michael M; Bingisser, Andreas C; Reichart, Peter A; Sendi, Pedram; Bosshardt, Dieter D; von Arx, Thomas
2015-06-01
The aim of this study was to evaluate the concordance of 2- and 3-dimensional radiography and histopathology in the diagnosis of periapical lesions. Patients were consecutively enrolled in this study provided that preoperative periapical radiography (PR) and cone-beam computed tomographic imaging of the tooth to be treated with apical surgery were performed. The periapical lesional tissue was histologically analyzed by 2 blinded examiners. The final histologic diagnosis was compared with the radiographic assessments of 4 blinded observers. The initial study material included 62 teeth in the same number of patients. Four lesions had to be excluded during processing, resulting in a final number of 58 evaluated cases (31 women and 27 men, mean age = 55 years). The final histologic diagnosis of the periapical lesions included 55 granulomas (94.8%) and 3 cysts (5.2%). Histologic analysis of the tissue samples from the apical lesions exhibited an almost perfect agreement between the 2 experienced investigators with an overall agreement of 94.83% (kappa = 0.8011). Radiographic assessment overestimated cysts by 28.4% (cone-beam computed tomographic imaging) and 20.7% (periapical radiography), respectively. Comparing the correlation of the radiographic diagnosis of 4 observers with the final histologic diagnosis, 2-dimensional (kappa = 0.104) and 3-dimensional imaging (kappa = 0.111) provided only minimum agreement. To establish a final diagnosis of an apical radiolucency, the tissue specimen should be evaluated histologically and specified as a granuloma (with/without epithelium) or a cyst. Analysis of 2-dimensional and 3-dimensional radiographic images alike results only in a tentative diagnosis that should be confirmed with biopsy. Copyright © 2015 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Metric on the space of quantum states from relative entropy. Tomographic reconstruction
NASA Astrophysics Data System (ADS)
Man'ko, Vladimir I.; Marmo, Giuseppe; Ventriglia, Franco; Vitale, Patrizia
2017-08-01
In the framework of quantum information geometry, we derive, from quantum relative Tsallis entropy, a family of quantum metrics on the space of full rank, N level quantum states, by means of a suitably defined coordinate free differential calculus. The cases N=2, N=3 are discussed in detail and notable limits are analyzed. The radial limit procedure has been used to recover quantum metrics for lower rank states, such as pure states. By using the tomographic picture of quantum mechanics we have obtained the Fisher-Rao metric for the space of quantum tomograms and derived a reconstruction formula of the quantum metric of density states out of the tomographic one. A new inequality obtained for probabilities of three spin-1/2 projections in three perpendicular directions is proposed to be checked in experiments with superconducting circuits.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Herholz, K.; Pietrzyk, U.; Wienhard, K.
1989-09-01
In 20 patients with ischemic cerebrovascular disease, classic migraine, or angiomas, we compared paired dynamic positron emission tomographic measurements of regional cerebral blood flow using both ({sup 15}O)water and ({sup 18}F)fluoromethane as tracers. Cerebral blood flow was also determined according to the autoradiographic technique with a bolus injection of ({sup 15}O)water. There were reasonable overall correlations between dynamic ({sup 15}O)water and ({sup 18}F)fluoromethane values for cerebral blood flow (r = 0.82) and between dynamic and autoradiographic ({sup 15}O)water values for cerebral blood flow (r = 0.83). We found a close correspondence between abnormal pathologic findings and visually evaluated cerebral bloodmore » flow tomograms obtained with the two tracers. On average, dynamic ({sup 15}O)water cerebral blood flow was 6% lower than that measured with ({sup 18}F)fluoromethane. There also was a general trend toward a greater underestimation with ({sup 15}O)water in high-flow areas, particularly in hyperemic areas, probably due to incomplete first-pass extraction of ({sup 15}O)water. Underestimation was not detected in low-flow areas or in the cerebellum. Absolute cerebral blood flow values were less closely correlated between tracers and techniques than cerebral blood flow patterns. The variability of the relation between absolute flow values was probably caused by confounding effects of the variation in the circulatory delay time. The autoradiographic technique was most sensitive to this type error.« less
Huang, P J; Chieng, P U; Lee, Y T; Chiang, F T; Tseng, Y Z; Liau, C S; Tseng, C D; Su, C T; Lien, W P
1992-11-01
Exercise thallium-201 imaging using single-photon emission computed tomography (SPECT) was evaluated in 154 patients with angiographically documented coronary artery disease (CAD) and in 25 normal subjects. Of the 154 patients with CAD, 134 (87%) had abnormal thallium images. By contrast, only 77 (50%) patients had ischemic ST-segment depression (p < 0.001). Among 25 normal subjects, 20 had normal exercise SPECT images. The specificity of exercise SPECT imaging (80% or 20/25) in excluding patients with CAD was not significantly higher than that of exercise electrocardiography (76% or 19/25). For the detection of individual vessel involvement by analysis of territories of perfusion abnormalities, the sensitivity and specificity of exercise SPECT were 72% and 96% for the left anterior descending, 78% and 85% for the right coronary, and 47% and 98% for the left circumflex artery. Ninety (group 1) of the 154 patients with CAD achieved adequate exercise end points (ischemic ST-segment depression or > 85% of maximal predicted heart rate) and 64 (group 2) did not. Exercise SPECT showed significantly more perfusion abnormalities in group 1 than in group 2 (96% vs 75%, p < 0.001). We conclude that: (1) exercise SPECT thallium imaging is more sensitive than exercise electrocardiography for detecting patients with CAD; (2) the sensitivity of the test is affected by the level of exercise; and (3) it is valuable in the identification of individual vessel involvement.
NASA Astrophysics Data System (ADS)
Ihsani, Alvin; Farncombe, Troy
2016-02-01
The modelling of the projection operator in tomographic imaging is of critical importance especially when working with algebraic methods of image reconstruction. This paper proposes a distance-driven projection method which is targeted to single-pinhole single-photon emission computed tomograghy (SPECT) imaging since it accounts for the finite size of the pinhole, and the possible tilting of the detector surface in addition to other collimator-specific factors such as geometric sensitivity. The accuracy and execution time of the proposed method is evaluated by comparing to a ray-driven approach where the pinhole is sub-sampled with various sampling schemes. A point-source phantom whose projections were generated using OpenGATE was first used to compare the resolution of reconstructed images with each method using the full width at half maximum (FWHM). Furthermore, a high-activity Mini Deluxe Phantom (Data Spectrum Corp., Durham, NC, USA) SPECT resolution phantom was scanned using a Gamma Medica X-SPECT system and the signal-to-noise ratio (SNR) and structural similarity of reconstructed images was compared at various projection counts. Based on the reconstructed point-source phantom, the proposed distance-driven approach results in a lower FWHM than the ray-driven approach even when using a smaller detector resolution. Furthermore, based on the Mini Deluxe Phantom, it is shown that the distance-driven approach has consistently higher SNR and structural similarity compared to the ray-driven approach as the counts in measured projections deteriorates.
40 CFR 60.1250 - What is my schedule for evaluating continuous emission monitoring systems?
Code of Federal Regulations, 2011 CFR
2011-07-01
... continuous emission monitoring systems? 60.1250 Section 60.1250 Protection of Environment ENVIRONMENTAL... Continuous Emission Monitoring § 60.1250 What is my schedule for evaluating continuous emission monitoring systems? (a) Conduct annual evaluations of your continuous emission monitoring systems no more than 13...
An evaluation of the effectiveness of adaptive histogram equalization for contrast enhancement.
Zimmerman, J B; Pizer, S M; Staab, E V; Perry, J R; McCartney, W; Brenton, B C
1988-01-01
Adaptive histogram equalization (AHE) and intensity windowing have been compared using psychophysical observer studies. Experienced radiologists were shown clinical CT (computerized tomographic) images of the chest. Into some of the images, appropriate artificial lesions were introduced; the physicians were then shown the images processed with both AHE and intensity windowing. They were asked to assess the probability that a given image contained the artificial lesion, and their accuracy was measured. The results of these experiments show that for this particular diagnostic task, there was no significant difference in the ability of the two methods to depict luminance contrast; thus, further evaluation of AHE using controlled clinical trials is indicated.
Tomographic Validation of the AWSoM Model of the Inner Corona During Solar Minima
NASA Astrophysics Data System (ADS)
Manchester, W.; Vásquez, A. M.; Lloveras, D. G.; Mac Cormack, C.; Nuevo, F.; Lopez-Fuentes, M.; Frazin, R. A.; van der Holst, B.; Landi, E.; Gombosi, T. I.
2017-12-01
Continuous improvement of MHD three-dimensional (3D) models of the global solar corona, such as the Alfven Wave Solar Model (AWSoM) of the Space Weather Modeling Framework (SWMF), requires testing their ability to reproduce observational constraints at a global scale. To that end, solar rotational tomography based on EUV image time-series can be used to reconstruct the 3D distribution of the electron density and temperature in the inner solar corona (r < 1.25 Rsun). The tomographic results, combined with a global coronal magnetic model, can further provide constraints on the energy input flux required at the coronal base to maintain stable structures. In this work, tomographic reconstructions are used to validate steady-state 3D MHD simulations of the inner corona using the latest version of the AWSoM model. We perform the study for selected rotations representative of solar minimum conditions, when the global structure of the corona is more axisymmetric. We analyse in particular the ability of the MHD simulation to match the tomographic results across the boundary region between the equatorial streamer belt and the surrounding coronal holes. The region is of particular interest as the plasma flow from that zone is thought to be related to the origin of the slow component of the solar wind.
Isaacson, Brandon; Kutz, Joe Walter; Mendelsohn, Dianne; Roland, Peter S
2009-04-01
To demonstrate the use of computed tomographic (CT) venography in selecting a surgical approach for cholesterol granulomas. Retrospective case review. Tertiary referral center. Three patients presented with symptomatic petrous apex cholesterol granulomas with extensive bone erosion involving the jugular fossa. Computed tomographic venography was performed on each patient before selecting a surgical approach for drainage. Localization of the jugular bulb in relation to the petrous carotid artery and basal turn of the cochlea was ascertained in each subject. Three patients with large symptomatic cholesterol granulomas were identified. Conventional CT demonstrated extensive bone erosion involving the jugular fossa in each patient. The location of the jugular bulb and its proximity to the petrous carotid artery and basal turn of the cochlea could not be determined with conventional temporal bone CT and magnetic resonance imaging. Computed tomographic venography provided the exact location of the jugular bulb in all 3 patients. The favorable position of the jugular bulb in all 3 cases permitted drainage of these lesions using an infracochlear approach. Computed tomographic venography provided invaluable information in 3 patients with large symptomatic cholesterol granulomas. All 3 patients were previously thought to be unsuitable candidates for an infracochlear or infralabyrinthine approach because of the unknown location of the jugular bulb.
Sodankylä ionospheric tomography data set 2003-2014
NASA Astrophysics Data System (ADS)
Norberg, Johannes; Roininen, Lassi; Kero, Antti; Raita, Tero; Ulich, Thomas; Markkanen, Markku; Juusola, Liisa; Kauristie, Kirsti
2016-07-01
Sodankylä Geophysical Observatory has been operating a receiver network for ionospheric tomography and collecting the produced data since 2003. The collected data set consists of phase difference curves measured from COSMOS navigation satellites from the Russian Parus network (Wood and Perry, 1980) and tomographic electron density reconstructions obtained from these measurements. In this study vertical total electron content (VTEC) values are integrated from the reconstructed electron densities to make a qualitative and quantitative analysis to validate the long-term performance of the tomographic system. During the observation period, 2003-2014, there were three to five operational stations at the Fennoscandia sector. Altogether the analysis consists of around 66 000 overflights, but to ensure the quality of the reconstructions, the examination is limited to cases with descending (north to south) overflights and maximum elevation over 60°. These constraints limit the number of overflights to around 10 000. Based on this data set, one solar cycle of ionospheric VTEC estimates is constructed. The measurements are compared against the International Reference Ionosphere (IRI)-2012 model, F10.7 solar flux index and sunspot number data. Qualitatively the tomographic VTEC estimate corresponds to reference data very well, but the IRI-2012 model results are on average 40 % higher than that of the tomographic results.
Multiphoton tomography to detect chemo- and biohazards
NASA Astrophysics Data System (ADS)
König, Karsten
2015-03-01
In vivo high-resolution multiphoton/CARS tomography provides optical biopsies with 300 nm lateral resolution with chemical fingerprints. Thousands of volunteers and patients have been investigated for early cancer diagnosis, evaluation of anti-ageing cosmetic products, and changes of cellular metabolism by UV exposure and decreased oxygen supply. The skin as the outermost and largest organ is also the major target of CB agents. Current UV-based sensors are useful for bio-aerosol sensing but not for evaluating exposed in vivo skin. Here we evaluate the use of 4D multiphoton/CARS tomographs based on near infrared femtosecond laser radiation, time-correlated single photon counting (FLIM) and white light generation by photonic crystal fibers to detect bio- and chemohazards in human in vivo skin using twophoton fluorescence, SHG, and Raman signals.
Siegal-Willott, Jessica L; Henrikson, Todd; Carpenter, James W; Andrews, Gordon A
2005-09-01
A 6-yr-old female leopard (Panthera pardus) was evaluated for a history of chronic obstipation of 4-mo duration. Radiographic, ultrasonographic, and computed tomographic evaluation revealed an intrapelvic mass that was compressing the distal colon. Because of the difficulties of postsurgical management of this animal, the owner requested euthanasia. On postmortem examination, a mass measuring 3 times 5 times 10 cm was found arising from the body of the uterus. Histopathologic evaluation of the mass revealed a leiomyoma of the uterus. This case report documents the presence of a uterine tumor in a large felid that resulted in constipation and obstipation. Additionally, the value and limitations of the imaging modalities used to provide diagnostic, prognostic, and treatment options are discussed.
Evaluating measurements of carbon dioxide emissions using a precision source--A natural gas burner.
Bryant, Rodney; Bundy, Matthew; Zong, Ruowen
2015-07-01
A natural gas burner has been used as a precise and accurate source for generating large quantities of carbon dioxide (CO2) to evaluate emissions measurements at near-industrial scale. Two methods for determining carbon dioxide emissions from stationary sources are considered here: predicting emissions based on fuel consumption measurements-predicted emissions measurements, and direct measurement of emissions quantities in the flue gas-direct emissions measurements. Uncertainty for the predicted emissions measurement was estimated at less than 1%. Uncertainty estimates for the direct emissions measurement of carbon dioxide were on the order of ±4%. The relative difference between the direct emissions measurements and the predicted emissions measurements was within the range of the measurement uncertainty, therefore demonstrating good agreement. The study demonstrates how independent methods are used to validate source emissions measurements, while also demonstrating how a fire research facility can be used as a precision test-bed to evaluate and improve carbon dioxide emissions measurements from stationary sources. Fossil-fuel-consuming stationary sources such as electric power plants and industrial facilities account for more than half of the CO2 emissions in the United States. Therefore, accurate emissions measurements from these sources are critical for evaluating efforts to reduce greenhouse gas emissions. This study demonstrates how a surrogate for a stationary source, a fire research facility, can be used to evaluate the accuracy of measurements of CO2 emissions.
Code of Federal Regulations, 2011 CFR
2011-07-01
... appendix F requirements to evaluate continuous emission monitoring systems? 60.1245 Section 60.1245... appendix F requirements to evaluate continuous emission monitoring systems? Yes, the accuracy tests for your sulfur dioxide continuous emission monitoring system require you to also evaluate your oxygen (or...