Sample records for endoscope locating device

  1. New devices and techniques for endoscopic closure of gastrointestinal perforations

    PubMed Central

    Li, Yue; Wu, Jian-Hua; Meng, Yan; Zhang, Qiang; Gong, Wei; Liu, Si-De

    2016-01-01

    Gastrointestinal perforations, which need to be managed quickly, are associated with high morbidity and mortality. Treatments used to close these perforations range from surgery to endoscopic therapy. Nowadays, with the development of new devices and techniques, endoscopic therapy is becoming more popular. However, there are different indications and clinical efficacies between different methods, because of the diverse properties of endoscopic devices and techniques. Successful management also depends on other factors, such as the precise location of the perforation, its size and the length of time between the occurrence and diagnosis. In this study, we performed a comprehensive review of various devices and introduced the different techniques that are considered effective to treat gastrointestinal perforations. In addition, we focused on the different methods used to achieve successful closure, based on the literature and our clinical experiences. PMID:27672268

  2. Optical instrument for measurement of vaginal coating thickness by drug delivery formulations

    NASA Astrophysics Data System (ADS)

    Henderson, Marcus H.; Peters, Jennifer J.; Walmer, David K.; Couchman, Grace M.; Katz, David F.

    2005-03-01

    An optical device has been developed for imaging the human vaginal epithelial surfaces, and quantitatively measuring distributions of coating thickness of drug delivery formulations—such as gels—applied for prophylaxis, contraception or therapy. The device consists of a rigid endoscope contained within a 27-mm-diam hollow, polished-transparent polycarbonate tube (150mm long) with a hemispherical cap. Illumination is from a xenon arc. The device is inserted into, and remains stationary within the vagina. A custom gearing mechanism moves the endoscope relative to the tube, so that it views epithelial surfaces immediately apposing its outer surface (i.e., 150mm long by 360° azimuthal angle). Thus, with the tube fixed relative to the vagina, the endoscope sites local regions at distinct and measurable locations that span the vaginal epithelium. The returning light path is split between a video camera and photomultiplier. Excitation and emission filters in the light path enable measurement of fluorescence of the sited region. Thus, the instrument captures video images simultaneously with photometric measurement of fluorescence of each video field [˜10mm diameter; formulations are labeled with 0.1%w/w United States Pharmacoepia (USP) injectable sodium fluorescein]. Position, time and fluorescence measurements are continuously displayed (on video) and recorded (to a computer database). The photomultiplier output is digitized to quantify fluorescence of the endoscope field of view. Quantification of the thickness of formulation coating of a surface sited by the device is achieved due to the linear relationship between thickness and fluorescence intensity for biologically relevant thin layers (of the order of 0.5mm). Summary measures of coating have been developed, focusing upon extent, location and uniformity. The device has begun to be applied in human studies of model formulations for prophylaxis against infection with HIV and other sexually transmitted pathogens.

  3. Endoscopic management of foreign bodies in the upper-GI tract: experience with 1088 cases in China.

    PubMed

    Li, Zhao-Shen; Sun, Zhen-Xing; Zou, Duo-Wu; Xu, Guo-Ming; Wu, Ren-Pei; Liao, Zhuan

    2006-10-01

    Reports on endoscopic management of ingested foreign bodies of the upper-GI tract in China are scarce. To report our experience and outcome in the management of ingestion of foreign bodies in Chinese patients. Between January 1980 and January 2005, a total of 1088 patients (685 men and 403 women; age range, 1 day to 96 years old) with suspected foreign bodies were admitted to our endoscopy center. All patients underwent endoscopic procedure after admission. Demographic and endoscopic data, including age, sex, and referral sources of patients, types, number and location of foreign bodies, associated upper-GI diseases, endoscopic methods, and accessory devices for removal of foreign bodies were collected and analyzed. A total of 1090 foreign bodies were found in 988 (90.8%) patients. The types of foreign bodies varied greatly: mainly food boluses, coins, fish bones, dental prostheses, or chicken bones. The foreign bodies were located in the pharynx (n = 12), the esophagus (n = 577), the stomach (n = 441), the duodenum (n = 50), and the surgical anastomosis (n = 10). The associated GI diseases (n = 88) included esophageal carcinoma (33.0%), stricture (23.9%), diverticulum (15.9%), postgastrectomy (11.4%), hiatal hernia (10.2%), and achalasia (5.7%). A rat-tooth forceps and a snare were the most frequently used accessory devices. The success rate for foreign-body removal was 94.1% (930/988). Ingestion of foreign bodies is a common clinic problem in China. Endoscopy procedures are frequently performed, and a high proportion of patients with foreign bodies require endoscopic intervention.

  4. Navigation technique for MR-endoscope system using a wireless accelerometer-based remote control device.

    PubMed

    Kumamoto, Etsuko; Takahashi, Akihiro; Matsuoka, Yuichiro; Morita, Yoshinori; Kutsumi, Hiromu; Azuma, Takeshi; Kuroda, Kagayaki

    2013-01-01

    The MR-endoscope system can perform magnetic resonance (MR) imaging during endoscopy and show the images obtained by using endoscope and MR. The MR-endoscope system can acquire a high-spatial resolution MR image with an intraluminal radiofrequency (RF) coil, and the navigation system shows the scope's location and orientation inside the human body and indicates MR images with a scope view. In order to conveniently perform an endoscopy and MR procedure, the design of the user interface is very important because it provides useful information. In this study, we propose a navigation system using a wireless accelerometer-based controller with Bluetooth technology and a navigation technique to set the intraluminal RF coil using the navigation system. The feasibility of using this wireless controller in the MR shield room was validated via phantom examinations of the influence on MR procedures and navigation accuracy. In vitro examinations using an isolated porcine stomach demonstrated the effectiveness of the navigation technique using a wireless remote-control device.

  5. Tips for safety in endoscopic submucosal dissection for colorectal tumors

    PubMed Central

    Naito, Yuji; Murakami, Takaaki; Hirose, Ryohei; Ogiso, Kiyoshi; Inada, Yutaka; Abdul Rani, Rafiz; Kishimoto, Mitsuo; Nakanishi, Masayoshi; Itoh, Yoshito

    2017-01-01

    In Japan, endoscopic submucosal dissection (ESD) becomes one of standard therapies for large colorectal tumors. Recently, the efficacy of ESD has been reported all over the world. However, it is still difficult even for Japanese experts in some situations. Right-sided location, large tumor size, high degree of fibrosis, difficult manipulation is related with the difficulty. However, improvements on ESD devices, suitable strategies, and increase of operators’ experiences enable us to solve these problems. In this chapter, we introduce recent topics about various difficult factors of colorectal ESD and the tips such as strategy, devices, injection, and traction method [Pocket-creation method (PCM) etc.]. PMID:28616400

  6. Optical instrument for measurement of vaginal coating thickness by drug delivery formulations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Henderson, Marcus H.; Peters, Jennifer J.; Walmer, David K.

    2005-03-01

    An optical device has been developed for imaging the human vaginal epithelial surfaces, and quantitatively measuring distributions of coating thickness of drug delivery formulations - such as gels - applied for prophylaxis, contraception or therapy. The device consists of a rigid endoscope contained within a 27-mm-diam hollow, polished-transparent polycarbonate tube (150 mm long) with a hemispherical cap. Illumination is from a xenon arc. The device is inserted into, and remains stationary within the vagina. A custom gearing mechanism moves the endoscope relative to the tube, so that it views epithelial surfaces immediately apposing its outer surface (i.e., 150 mm longmore » by 360 deg. azimuthal angle). Thus, with the tube fixed relative to the vagina, the endoscope sites local regions at distinct and measurable locations that span the vaginal epithelium. The returning light path is split between a video camera and photomultiplier. Excitation and emission filters in the light path enable measurement of fluorescence of the sited region. Thus, the instrument captures video images simultaneously with photometric measurement of fluorescence of each video field [{approx}10 mm diameter; formulations are labeled with 0.1% w/w United States Pharmacoepia (USP) injectable sodium fluorescein]. Position, time and fluorescence measurements are continuously displayed (on video) and recorded (to a computer database). The photomultiplier output is digitized to quantify fluorescence of the endoscope field of view. Quantification of the thickness of formulation coating of a surface sited by the device is achieved due to the linear relationship between thickness and fluorescence intensity for biologically relevant thin layers (of the order of 0.5 mm). Summary measures of coating have been developed, focusing upon extent, location and uniformity. The device has begun to be applied in human studies of model formulations for prophylaxis against infection with HIV and other sexually transmitted pathogens.« less

  7. Biplane reconstruction and visualization of virtual endoscopic and fluoroscopic views for interventional device navigation

    NASA Astrophysics Data System (ADS)

    Wagner, Martin G.; Strother, Charles M.; Schafer, Sebastian; Mistretta, Charles A.

    2016-03-01

    Biplane fluoroscopic imaging is an important tool for minimally invasive procedures for the treatment of cerebrovascular diseases. However, finding a good working angle for the C-arms of the angiography system as well as navigating based on the 2D projection images can be a difficult task. The purpose of this work is to propose a novel 4D reconstruction algorithm for interventional devices from biplane fluoroscopy images and to propose new techniques for a better visualization of the results. The proposed reconstruction methods binarizes the fluoroscopic images using a dedicated noise reduction algorithm for curvilinear structures and a global thresholding approach. A topology preserving thinning algorithm is then applied and a path search algorithm minimizing the curvature of the device is used to extract the 2D device centerlines. Finally, the 3D device path is reconstructed using epipolar geometry. The point correspondences are determined by a monotonic mapping function that minimizes the reconstruction error. The three dimensional reconstruction of the device path allows the rendering of virtual fluoroscopy images from arbitrary angles as well as 3D visualizations like virtual endoscopic views or glass pipe renderings, where the vessel wall is rendered with a semi-transparent material. This work also proposes a combination of different visualization techniques in order to increase the usability and spatial orientation for the user. A combination of synchronized endoscopic and glass pipe views is proposed, where the virtual endoscopic camera position is determined based on the device tip location as well as the previous camera position using a Kalman filter in order to create a smooth path. Additionally, vessel centerlines are displayed and the path to the target is highlighted. Finally, the virtual endoscopic camera position is also visualized in the glass pipe view to further improve the spatial orientation. The proposed techniques could considerably improve the workflow of minimally invasive procedures for the treatment of cerebrovascular diseases.

  8. Endoscopic Management of Peri-Pancreatic Fluid Collections.

    PubMed

    Yip, Hon Chi; Teoh, Anthony Yuen Bun

    2017-09-15

    In the past decade, there has been a progressive paradigm shift in the management of peri-pancreatic fluid collections after acute pancreatitis. Refinements in the definitions of fluid collections from the updated Atlanta classification have enabled better communication amongst physicians in an effort to formulate optimal treatments. Endoscopic ultrasound (EUS)-guided drainage of pancreatic pseudocysts has emerged as the procedure of choice over surgical cystogastrostomy. The approach provides similar success rates with low complications and better quality of life compared with surgery. However, an endoscopic "step up" approach in the management of pancreatic walled-off necrosis has also been advocated. Both endoscopic and percutaneous drainage routes may be used depending on the anatomical location of the collections. New-generation large diameter EUS-specific stent systems have also recently been described. The device allows precise and effective drainage of the collections and permits endoscopic necrosectomy through the stents.

  9. 21 CFR 882.1480 - Neurological endoscope.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Neurological endoscope. 882.1480 Section 882.1480...) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Diagnostic Devices § 882.1480 Neurological endoscope. (a) Identification. A neurological endoscope is an instrument with a light source used to view the inside of the...

  10. 21 CFR 882.1480 - Neurological endoscope.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Neurological endoscope. 882.1480 Section 882.1480...) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Diagnostic Devices § 882.1480 Neurological endoscope. (a) Identification. A neurological endoscope is an instrument with a light source used to view the inside of the...

  11. Endoscope field of view measurement.

    PubMed

    Wang, Quanzeng; Khanicheh, Azadeh; Leiner, Dennis; Shafer, David; Zobel, Jurgen

    2017-03-01

    The current International Organization for Standardization (ISO) standard (ISO 8600-3: 1997 including Amendment 1: 2003) for determining endoscope field of view (FOV) does not accurately characterize some novel endoscopic technologies such as endoscopes with a close focus distance and capsule endoscopes. We evaluated the endoscope FOV measurement method (the FOV WS method) in the current ISO 8600-3 standard and proposed a new method (the FOV EP method). We compared the two methods by measuring the FOV of 18 models of endoscopes (one device for each model) from seven key international manufacturers. We also estimated the device to device variation of two models of colonoscopes by measuring several hundreds of devices. Our results showed that the FOV EP method was more accurate than the FOV WS method, and could be used for all endoscopes. We also found that the labelled FOV values of many commercial endoscopes are significantly overstated. Our study can help endoscope users understand endoscope FOV and identify a proper method for FOV measurement. This paper can be used as a reference to revise the current endoscope FOV measurement standard.

  12. Endoscope field of view measurement

    PubMed Central

    Wang, Quanzeng; Khanicheh, Azadeh; Leiner, Dennis; Shafer, David; Zobel, Jurgen

    2017-01-01

    The current International Organization for Standardization (ISO) standard (ISO 8600-3: 1997 including Amendment 1: 2003) for determining endoscope field of view (FOV) does not accurately characterize some novel endoscopic technologies such as endoscopes with a close focus distance and capsule endoscopes. We evaluated the endoscope FOV measurement method (the FOVWS method) in the current ISO 8600-3 standard and proposed a new method (the FOVEP method). We compared the two methods by measuring the FOV of 18 models of endoscopes (one device for each model) from seven key international manufacturers. We also estimated the device to device variation of two models of colonoscopes by measuring several hundreds of devices. Our results showed that the FOVEP method was more accurate than the FOVWS method, and could be used for all endoscopes. We also found that the labelled FOV values of many commercial endoscopes are significantly overstated. Our study can help endoscope users understand endoscope FOV and identify a proper method for FOV measurement. This paper can be used as a reference to revise the current endoscope FOV measurement standard. PMID:28663840

  13. An automatic detection method for the boiler pipe header based on real-time image acquisition

    NASA Astrophysics Data System (ADS)

    Long, Yi; Liu, YunLong; Qin, Yongliang; Yang, XiangWei; Li, DengKe; Shen, DingJie

    2017-06-01

    Generally, an endoscope is used to test the inner part of the thermal power plants boiler pipe header. However, since the endoscope hose manual operation, the length and angle of the inserted probe cannot be controlled. Additionally, it has a big blind spot observation subject to the length of the endoscope wire. To solve these problems, an automatic detection method for the boiler pipe header based on real-time image acquisition and simulation comparison techniques was proposed. The magnetic crawler with permanent magnet wheel could carry the real-time image acquisition device to complete the crawling work and collect the real-time scene image. According to the obtained location by using the positioning auxiliary device, the position of the real-time detection image in a virtual 3-D model was calibrated. Through comparing of the real-time detection images and the computer simulation images, the defects or foreign matter fall into could be accurately positioning, so as to repair and clean up conveniently.

  14. Endoscopic Devices for Obesity.

    PubMed

    Sampath, Kartik; Dinani, Amreen M; Rothstein, Richard I

    2016-06-01

    The obesity epidemic, recognized by the World Health Organization in 1997, refers to the rising incidence of obesity worldwide. Lifestyle modification and pharmacotherapy are often ineffective long-term solutions; bariatric surgery remains the gold standard for long-term obesity weight loss. Despite the reported benefits, it has been estimated that only 1% of obese patients will undergo surgery. Endoscopic treatment for obesity represents a potential cost-effective, accessible, minimally invasive procedure that can function as a bridge or alternative intervention to bariatric surgery. We review the current endoscopic bariatric devices including space occupying devices, endoscopic gastroplasty, aspiration technology, post-bariatric surgery endoscopic revision, and obesity-related NOTES procedures. Given the diverse devices already FDA approved and in development, we discuss the future directions of endoscopic therapies for obesity.

  15. Shape memory alloy-based biopsy device for active locomotive intestinal capsule endoscope.

    PubMed

    Le, Viet Ha; Hernando, Leon-Rodriguez; Lee, Cheong; Choi, Hyunchul; Jin, Zhen; Nguyen, Kim Tien; Go, Gwangjun; Ko, Seong-Young; Park, Jong-Oh; Park, Sukho

    2015-03-01

    Recently, capsule endoscopes have been used for diagnosis in digestive organs. However, because a capsule endoscope does not have a locomotive function, its use has been limited to small tubular digestive organs, such as small intestine and esophagus. To address this problem, researchers have begun studying an active locomotive intestine capsule endoscope as a medical instrument for the whole gastrointestinal tract. We have developed a capsule endoscope with a small permanent magnet that is actuated by an electromagnetic actuation system, allowing active and flexible movement in the patient's gut environment. In addition, researchers have noted the need for a biopsy function in capsule endoscope for the definitive diagnosis of digestive diseases. Therefore, this paper proposes a novel robotic biopsy device for active locomotive intestine capsule endoscope. The proposed biopsy device has a sharp blade connected with a shape memory alloy actuator. The biopsy device measuring 12 mm in diameter and 3 mm in length was integrated into our capsule endoscope prototype, where the device's sharp blade was activated and exposed by the shape memory alloy actuator. Then the electromagnetic actuation system generated a specific motion of the capsule endoscope to extract the tissue sample from the intestines. The final biopsy sample tissue had a volume of about 6 mm(3), which is a sufficient amount for a histological analysis. Consequently, we proposed the working principle of the biopsy device and conducted an in-vitro biopsy test to verify the feasibility of the biopsy device integrated into the capsule endoscope prototype using the electro-magnetic actuation system. © IMechE 2015.

  16. The Regulatory Perspectives on Endoscopic Devices for Obesity.

    PubMed

    Marrone, April K; Antonino, Mark J; Silverstein, Joshua S; Betz, Martha W; Venkataraman-Rao, Priya; Golding, Martin; Cordray, Diane; Cooper, Jeffrey W

    2017-04-01

    The recent increase in US Food and Drug Administration-approved weight-loss devices has diversified obesity treatment options. The regulatory pathways for endoscopically placed weight-loss devices and considerations for clinical trials are discussed, including the benefit-risk paradigm intended to aid in weight-loss-device trial development. Also discussed is the benefit-risk analysis of recently approved endoscopic devices. A strategic priority of the FDA Center for Devices and Radiological Health is to increase the use of patient input in decision making. Thus, we consider how endoscopic weight-loss devices with profiles similar to those that have been approved may be viewed in a patient preference study. Published by Elsevier Inc.

  17. A non-invasive navigation system for retargeting gastroscopic lesions.

    PubMed

    Liu, Jiquan; Wang, Bin; Hu, Weiling; Zong, Yun; Si, Jianmin; Duan, Huilong

    2014-01-01

    Biopsy is a traditional endoscopic surveillance of premalignant gastric lesions, and endoscopic tattooing is used for marking the biopsy's location. However, the tattooing has several disadvantages. For example, the procedure is an invasive operation and may not be durable due to the diffusion. Moreover, it is procedurally cumbersome with an associated risk of technical failure. In this study, a computer aided endoscopic navigation system (CAEN system) was developed for a non-invasive biopsy procedure. The CAEN system consists of a new, designed six degree of freedom (6-DOF) tracking endoscope device and a computer simulated work station. During the procedure, the endoscopist uses the tip of the tracking endoscope to touch the lesion. Then, the lesion's location is recorded in the work station, which then guides the endoscopist in retargeting the lesions in the follow-ups. The clinical experimental results demonstrate that the accuracy at the angularis is 5.2 ± 2.8 mm, at the antral lesser curvature is 7.2 ± 2.0 mm, at the antral greater curvature is 6.3 ± 3.1 mm, at the antral posterior wall is 8.2 ± 1.6 mm, and at the antral anterior wall is 7.9 ± 1.3 mm. The mean accuracy is 7.5 mm, and the P-value is 0.023, which is likely suitable for clinical practice. Furthermore, the proposed CAEN system requires less procedural time than the tattooing.

  18. Non-Exposure, Device-Assisted Endoscopic Full-thickness Resection.

    PubMed

    Bauder, Markus; Schmidt, Arthur; Caca, Karel

    2016-04-01

    Recent developments have expanded the frontier of interventional endoscopy toward more extended resections following surgical principles. This article presents two new device-assisted techniques for endoscopic full-thickness resection in the upper and lower gastrointestinal tract. Both methods are nonexposure techniques avoiding exposure of gastrointestinal contents to the peritoneal cavity by a "close first-cut later" principle. The full-thickness resection device is a novel over-the-scope device designed for clip-assisted full-thickness resection of colorectal lesions. Endoscopic full-thickness resection of gastric subepithelial tumors can be performed after placing transmural sutures underneath the tumor with a suturing device originally designed for endoscopic antireflux therapy. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. Endoscopic techniques and management of foreign body ingestion and food bolus impaction in the upper gastrointestinal tract: a retrospective analysis of 139 cases.

    PubMed

    Katsinelos, Panagiotis; Kountouras, Jannis; Paroutoglou, George; Zavos, Christos; Mimidis, Kostas; Chatzimavroudis, Grigoris

    2006-10-01

    Ingested foreign bodies and food bolus impaction are frequently seen in endoscopic practice. Successful foreign body and food bolus removal may depend on the method used, the choice of device, and the experience level of the endoscopist, although few papers report experience and outcome of tertiary centers. To investigate the effectiveness of our protocol designed for removal of ingested foreign bodies and food boluses. We retrospectively reviewed all patients with a diagnosis of foreign body ingestion and food bolus impaction from 1994 to 2005 identified by computer search. Patients were excluded if medical record was incomplete. The analysis included 171 patients. Foreign bodies and impacted food boluses were found in 77 and 62 patients, respectively. In 32 cases (23%), the foreign bodies passed spontaneously through the gastrointestinal tract. The overall success rate for endoscopic management was obtained in 137 patients (98.6%). Surgical removal of a foreign body was required in only 2 cases (1.4%). According to the type and location of the foreign object and food bolus we used Dormia baskets, retrieval forceps, polypectomy snares, and all sizes of Roth net. No complications relating to the endoscopic procedure were observed; 50 patients (35.2%) had an underlying esophageal disease. Endoscopic removal of upper gastrointestinal tract foreign bodies and food bolus impaction is efficacious and safe. Especially the Roth net is the best device for safe retrieval of food boluses and button disc batteries.

  20. Review of Pure Endoscopic Full-Thickness Resection of the Upper Gastrointestinal Tract

    PubMed Central

    Mori, Hirohito; Kobara, Hideki; Nishiyama, Noriko; Fujihara, Shintaro; Masaki, Tsutomu

    2015-01-01

    Natural-orifice transluminal endoscopic surgery (NOTES) using flexible endoscopy has attracted attention as a minimally invasive surgical method that does not cause an operative wound on the body surface. However, minimizing the number of devices involved in endoscopic, compared to laparoscopic, surgeries has remained a challenge, causing endoscopic surgeries to gradually be phased out of use. If a flexible endoscopic full-thickness suturing device and a counter-traction device were developed to expand the surgical field for gastrointestinal-tract collapse, then endoscopic full-thickness resection using NOTES, which is seen as an extension of endoscopic submucosal dissection for full-thickness excision of tumors involving the gastrointestinal-tract wall, might become an extremely minimally invasive surgical method that could be used to resect only full-thickness lesions approached by the shortest distance via the mouth. It is expected that gastroenterological endoscopists will use this surgery if device development is advanced. This extremely minimally invasive surgery would have an immeasurable impact with regard to mitigating the burden on patients and reducing healthcare costs. Development of a new surgical method using a multipurpose flexible endoscope is therefore considered a socially urgent issue. PMID:26343069

  1. Video-based measurements for wireless capsule endoscope tracking

    NASA Astrophysics Data System (ADS)

    Spyrou, Evaggelos; Iakovidis, Dimitris K.

    2014-01-01

    The wireless capsule endoscope is a swallowable medical device equipped with a miniature camera enabling the visual examination of the gastrointestinal (GI) tract. It wirelessly transmits thousands of images to an external video recording system, while its location and orientation are being tracked approximately by external sensor arrays. In this paper we investigate a video-based approach to tracking the capsule endoscope without requiring any external equipment. The proposed method involves extraction of speeded up robust features from video frames, registration of consecutive frames based on the random sample consensus algorithm, and estimation of the displacement and rotation of interest points within these frames. The results obtained by the application of this method on wireless capsule endoscopy videos indicate its effectiveness and improved performance over the state of the art. The findings of this research pave the way for a cost-effective localization and travel distance measurement of capsule endoscopes in the GI tract, which could contribute in the planning of more accurate surgical interventions.

  2. 21 CFR 876.1500 - Endoscope and accessories.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... within this generic type of device include cleaning accessories for endoscopes, photographic accessories for endoscopes, nonpowered anoscopes, binolcular attachments for endoscopes, pocket battery boxes... endoscope, smoke removal tube, rechargeable battery box, pocket battery box, bite block for endoscope, and...

  3. 21 CFR 876.1500 - Endoscope and accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... within this generic type of device include cleaning accessories for endoscopes, photographic accessories for endoscopes, nonpowered anoscopes, binolcular attachments for endoscopes, pocket battery boxes... endoscope, smoke removal tube, rechargeable battery box, pocket battery box, bite block for endoscope, and...

  4. 21 CFR 876.1500 - Endoscope and accessories.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... within this generic type of device include cleaning accessories for endoscopes, photographic accessories for endoscopes, nonpowered anoscopes, binolcular attachments for endoscopes, pocket battery boxes... endoscope, smoke removal tube, rechargeable battery box, pocket battery box, bite block for endoscope, and...

  5. 21 CFR 876.1500 - Endoscope and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... within this generic type of device include cleaning accessories for endoscopes, photographic accessories for endoscopes, nonpowered anoscopes, binolcular attachments for endoscopes, pocket battery boxes... endoscope, smoke removal tube, rechargeable battery box, pocket battery box, bite block for endoscope, and...

  6. 21 CFR 876.1500 - Endoscope and accessories.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... within this generic type of device include cleaning accessories for endoscopes, photographic accessories for endoscopes, nonpowered anoscopes, binolcular attachments for endoscopes, pocket battery boxes... endoscope, smoke removal tube, rechargeable battery box, pocket battery box, bite block for endoscope, and...

  7. Risk factors for complications associated with upper gastrointestinal foreign bodies

    PubMed Central

    Hong, Kyong Hee; Kim, Yoon Jae; Kim, Jae Hak; Chun, Song Wook; Kim, Hee Man; Cho, Jae Hee

    2015-01-01

    AIM: To investigate predictive risk factors associated with complications in the endoscopic removal of foreign bodies from the upper gastrointestinal tract. METHODS: We retrospectively reviewed the medical records of 194 patients with a diagnosis of foreign body impaction in the upper gastrointestinal tract, confirmed by endoscopy, at two university hospital in South Korea. Patient demographic data, including age, gender, intention to ingestion, symptoms at admission, and comorbidities, were collected. Clinical features of the foreign bodies, such as type, size, sharpness of edges, number, and location, were analyzed. Endoscopic data those were analyzed included duration of foreign body impaction, duration of endoscopic performance, endoscopic device, days of hospitalization, complication rate, 30-d mortality rate, and the number of operations related to foreign body removal. RESULTS: The types of upper gastrointestinal foreign bodies included fish bones, drugs, shells, meat, metal, and animal bones. The locations of impacted foreign bodies were the upper esophagus (57.2%), mid esophagus (28.4%), stomach (10.8%), and lower esophagus (3.6%). The median size of the foreign bodies was 26.2 ± 16.7 mm. Among 194 patients, endoscopic removal was achieved in 189, and complications developed in 51 patients (26.9%). Significant complications associated with foreign body impaction and removal included deep lacerations with minor bleeding (n = 31, 16%), ulcer (n = 11, 5.7%), perforation (n = 3, 1.5%), and abscess (n = 1, 0.5%). Four patients underwent operations because of incomplete endoscopic foreign body extraction. In multivariate analyses, risk factors for endoscopic complications and failure were sharpness (HR = 2.48, 95%CI: 1.07-5.72; P = 0.034) and a greater than 12-h duration of impaction (HR = 2.42, 95%CI: 1.12-5.25, P = 0.025). CONCLUSION: In cases of longer than 12 h since foreign body ingestion or sharp-pointed objects, rapid endoscopic intervention should be provided in patients with ingested foreign bodies. PMID:26185385

  8. Integrated pressure and temperature sensor with high immunity against external disturbance for flexible endoscope operation

    NASA Astrophysics Data System (ADS)

    Maeda, Yusaku; Maeda, Kohei; Kobara, Hideki; Mori, Hirohito; Takao, Hidekuni

    2017-04-01

    In this study, an integrated pressure and temperature sensor device for a flexible endoscope with long-term stability in in vivo environments was developed and demonstrated. The sensor, which is embedded in the thin wall of the disposable endoscope hood, is intended for use in endoscopic surgery. The device surface is coated with a Cr layer to prevent photoelectronic generation induced by the strong light of the endoscope. The integrated temperature sensor allows compensation for the effect of the temperature drift on a pressure signal. The fabricated device pressure resolution is 0.4 mmHg; the corresponding pressure error is 3.2 mmHg. The packaged device was used in a surgical simulation in an animal experiment. Pressure and temperature monitoring was achieved even in a pH 1 acid solution. The device enables intraluminal pressure and temperature measurements of the stomach, which facilitate the maintenance of internal stomach conditions. The applicability of the sensor was successfully demonstrated in animal experiments.

  9. Accessory Devices Frequently Used for Endoscopic Submucosal Dissection

    PubMed Central

    Choi, Hyuk Soon; Chun, Hoon Jai

    2017-01-01

    Endoscopic submucosal dissection (ESD) is increasingly being considered an essential component of treatment for early gastrointestinal cancers and subepithelial tumors. The ESD technique owes its popularity to the development of sophisticated instruments used for ESD. With an increase in the number of ESD procedures performed, there is rapid development in the number and types of endoscopic accessory devices used for such procedures. Despite the large numbers of new devices developed and marketed, the use of ESD instruments and accessory devices is largely determined by individual preferences and experiences. Accessory devices frequently used during ESD are important tools for ESD techniques. Each instrument possesses characteristic advantages and disadvantages associated with its use, and no one instrument is superior in all respects to others. In this article, we review the characteristics of endoscopic electrical knives, cap and hood, and hemostatic devices commonly used in ESD. PMID:28609818

  10. Endoscopic placement of the small-bowel video capsule by using a capsule endoscope delivery device.

    PubMed

    Holden, Jeremy P; Dureja, Parul; Pfau, Patrick R; Schwartz, Darren C; Reichelderfer, Mark; Judd, Robert H; Danko, Istvan; Iyer, Lalitha V; Gopal, Deepak V

    2007-05-01

    Capsule endoscopy performed via the traditional peroral route is technically challenging in patients with dysphagia, gastroparesis, and/or abnormal upper-GI (UGI) anatomy. To describe the indications and outcomes of cases in which the AdvanCE capsule endoscope delivery device, which has recently been cleared by the Food and Drug Administration, was used. Retrospective, descriptive, case series. Tertiary care, university hospital. We report a case series of 16 consecutive patients in whom the AdvanCE delivery device was used. The study period was May 2005 through July 2006. Endoscopic delivery of the video capsule to the proximal small bowel by using the AdvanCE delivery device. Indications, technique, and completeness of small bowel imaging in patients who underwent endoscopic video capsule delivery. The AdvanCE delivery device was used in 16 patients ranging in age from 3 to 74 years. The primary indications for endoscopic delivery included inability to swallow the capsule (10), altered UGI anatomy (4), and gastroparesis (2). Of the 4 patients with altered UGI anatomy, 3 had dual intestinal loop anatomy (ie, Bilroth-II procedure, Whipple surgery, Roux-en-Y gastric bypass) and 1 had a failed Nissen fundoplication. In all cases, the capsule was easily deployed without complication, and complete small intestinal imaging was achieved. Small patient size. Endoscopic placement of the Given PillCam by use of the AdvanCE delivery device was safe and easily performed in patients for whom capsule endoscopy would otherwise have been contraindicated or technically challenging.

  11. Emergency treatment of esophageal varix incarceration in the endoscope and ligation device during endoscopic variceal rubber band ligation

    PubMed Central

    Zhao, Hong; Cheng, Jilin; Xu, Yahong; Lu, Cuili; Huang, Shaoping; Fan, Zhenyu; Shi, Yuxin

    2014-01-01

    Sclerotherapy and endoscopic esophageal variceal ligation (EVL) are commonly used to treat and prevent variceal bleeding. As of today, there has been no report on an unexpected incarceration of a varix hooked on with the bands from the endoscopic EVL device. We recently experienced this emergency while using the 7-band ring endoscopic EVL device (Boston Scientific Corp., Boston, MA) for prophylaxis of variceal bleeding. In this case, the varix body itself was accidently incarcerated in the crevice of the esophageal endoscope after highly negative pressure of absorption was applied on the endoscope. In this situation, using force to take out the gastroscope was not an option as it would tear the vein and cause massive hemorrhage. We were managed to ligate the varix with rubber bands while releasing the incarceration. We observed that ligation of the varix at the same position using all seven ligation bands resulted in disappearance of the targeted varix. The surrounding esophageal mucosa became smooth after the treatment. PMID:25550983

  12. Prospective, randomized comparison of 3 different hemoclips for the treatment of acute upper GI hemorrhage in an established experimental setting.

    PubMed

    Kato, Masayuki; Jung, Yunho; Gromski, Mark A; Chuttani, Ram; Matthes, Kai

    2012-01-01

    Recently, endoscopic clip application devices have undergone redesign and improvements to optimize their clinical use and effectiveness. Initially designed for the treatment of bleeding nonvariceal lesions, these devices are also increasingly used for the closure of perforations, fistulas, and anastomotic leaks. Several clinical studies, both randomized and nonrandomized, have used endoscopic hemoclips for hemostasis. However, no comparative studies have yet been reported in the literature comparing the latest endoscopic clip devices for usability and effectiveness for hemostasis of acute upper GI hemorrhage. We aimed to compare the usability and efficacy of 3 different types of endoscopic clip application devices in an established experimental setting by using a porcine ex-vivo simulator of upper GI hemorrhage. Randomized, controlled, ex-vivo study. Academic medical center. Spurting vessels were created within ex-vivo porcine stomachs as published in prior studies. The vessels were attached to a pressure transducer to record the pressure of the circulating blood replacement. Before the initiation of bleeding, each vessel was randomized to 1 of 3 endoscopic clipping devices: 2 different commonly used hemoclips deployed through the working channel and 1 novel clip deployed via an over-the-scope applications device. Two investigators treated 45 bleeding sites (15 bleeding sites for each device at various randomized locations in the stomach: fundus, body, and antrum). Usability was measured via the endpoints of procedure time and quantity of clips required to achieve hemostasis. Efficacy was measured via the endpoint of pressure increase (Δp) from baseline to after treatment. All of the 45 hemostasis treatments were carried out successfully. The mean procedure times were significantly different among the hemoclips, with the clip deployed in an over-the-scope fashion requiring significantly less time to attain hemostasis compared with the other 2 clips. For number of clips needed to attain hemostasis, the clip deployed in an over-the-scope fashion was significantly superior to the others. There were also significant differences among the changes in pressure (Δp ± SD) among the different hemoclips tested. Ex-vivo study. In this prospective, randomized ex-vivo study, we observed significant differences in the usability (time to achieve hemostasis and number of clips required) and the efficacy (change in pressure achieved by the hemoclips) among the 3 clips. The clip applied in the over-the-scope fashion was superior to the other 2 tested clips with regard to time to achieve hemostasis and number of clips required. Copyright © 2012 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  13. 21 CFR 876.4300 - Endoscopic electrosurgical unit and accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... accessories is a device used to perform electrosurgical procedures through an endoscope. This generic type of device includes the electrosurgical generator, patient plate, electric biopsy forceps, electrode...

  14. Fiber-optic fluorescence imaging

    PubMed Central

    Flusberg, Benjamin A; Cocker, Eric D; Piyawattanametha, Wibool; Jung, Juergen C; Cheung, Eunice L M; Schnitzer, Mark J

    2010-01-01

    Optical fibers guide light between separate locations and enable new types of fluorescence imaging. Fiber-optic fluorescence imaging systems include portable handheld microscopes, flexible endoscopes well suited for imaging within hollow tissue cavities and microendoscopes that allow minimally invasive high-resolution imaging deep within tissue. A challenge in the creation of such devices is the design and integration of miniaturized optical and mechanical components. Until recently, fiber-based fluorescence imaging was mainly limited to epifluorescence and scanning confocal modalities. Two new classes of photonic crystal fiber facilitate ultrashort pulse delivery for fiber-optic two-photon fluorescence imaging. An upcoming generation of fluorescence imaging devices will be based on microfabricated device components. PMID:16299479

  15. A multiport MR-compatible neuroendoscope: spanning the gap between rigid and flexible scopes

    PubMed Central

    Manjila, Sunil; Mencattelli, Margherita; Rosa, Benoit; Price, Karl; Fagogenis, Georgios; Dupont, Pierre E.

    2017-01-01

    OBJECTIVE Rigid endoscopes enable minimally invasive access to the ventricular system; however, the operative field is limited to the instrument tip, necessitating rotation of the entire instrument and causing consequent tissue compression while reaching around corners. Although flexible endoscopes offer tip steerability to address this limitation, they are more difficult to control and provide fewer and smaller working channels. A middle ground between these instruments—a rigid endoscope that possesses multiple instrument ports (for example, one at the tip and one on the side)—is proposed in this article, and a prototype device is evaluated in the context of a third ventricular colloid cyst resection combined with septostomy. METHODS A prototype neuroendoscope was designed and fabricated to include 2 optical ports, one located at the instrument tip and one located laterally. Each optical port includes its own complementary metal-oxide semiconductor (CMOS) chip camera, light-emitting diode (LED) illumination, and working channels. The tip port incorporates a clear silicone optical window that provides 2 additional features. First, for enhanced safety during tool insertion, instruments can be initially seen inside the window before they extend from the scope tip. Second, the compliant tip can be pressed against tissue to enable visualization even in a blood-filled field. These capabilities were tested in fresh porcine brains. The image quality of the multiport endoscope was evaluated using test targets positioned at clinically relevant distances from each imaging port, comparing it with those of clinical rigid and flexible neuroendoscopes. Human cadaver testing was used to demonstrate third ventricular colloid cyst phantom resection through the tip port and a septostomy performed through the lateral port. To extend its utility in the treatment of periventricular tumors using MR-guided laser therapy, the device was designed to be MR compatible. Its functionality and compatibility inside a 3-T clinical scanner were also tested in a brain from a freshly euthanized female pig. RESULTS Testing in porcine brains confirmed the multiport endoscope’s ability to visualize tissue in a blood-filled field and to operate inside a 3-T MRI scanner. Cadaver testing confirmed the device’s utility in operating through both of its ports and performing combined third ventricular colloid cyst resection and septostomy with an endoscope rotation of less than 5°. CONCLUSIONS The proposed design provides freedom in selecting both the number and orientation of imaging and instrument ports, which can be customized for each ventricular pathological entity. The lightweight, easily manipulated device can provide added steerability while reducing the potential for the serious brain distortion that happens with rigid endoscope navigation. This capability would be particularly valuable in treating hydrocephalus, both primary and secondary (due to tumors, cysts, and so forth). Magnetic resonance compatibility can aid in endoscope-assisted ventricular aqueductal plasty and stenting, the management of multiloculated complex hydrocephalus, and postinflammatory hydrocephalus in which scarring obscures the ventricular anatomy. PMID:27581309

  16. TU-AB-202-12: A Novel Method to Map Endoscopic Video to CT for Treatment Planning and Toxicity Analysis in Radiation Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ingram, W; Yang, J; Beadle, B

    Purpose: Endoscopic examinations are routine procedures for head-and-neck cancer patients. Our goal is to develop a method to map the recorded video to CT, providing valuable information for radiotherapy treatment planning and toxicity analysis. Methods: We map video frames to CT via virtual endoscopic images rendered at the real endoscope’s CT-space coordinates. We developed two complementary methods to find these coordinates by maximizing real-to-virtual image similarity:(1)Endoscope Tracking: moves the virtual endoscope frame-by-frame until the desired frame is reached. Utilizes prior knowledge of endoscope coordinates, but sensitive to local optima. (2)Location Search: moves the virtual endoscope along possible paths through themore » volume to find the desired frame. More robust, but more computationally expensive. We tested these methods on clay phantoms with embedded markers for point mapping and protruding bolus material for contour mapping, and we assessed them qualitatively on three patient exams. For mapped points we calculated 3D-distance errors, and for mapped contours we calculated mean absolute distances (MAD) from CT contours. Results: In phantoms, Endoscope Tracking had average point error=0.66±0.50cm and average bolus MAD=0.74±0.37cm for the first 80% of each video. After that the virtual endoscope got lost, increasing these values to 4.73±1.69cm and 4.06±0.30cm. Location Search had point error=0.49±0.44cm and MAD=0.53±0.28cm. Point errors were larger where the endoscope viewed the surface at shallow angles<10 degrees (1.38±0.62cm and 1.22±0.69cm for Endoscope Tracking and Location Search, respectively). In patients, Endoscope Tracking did not make it past the nasal cavity. However, Location Search found coordinates near the correct location for 70% of test frames. Its performance was best near the epiglottis and in the nasal cavity. Conclusion: Location Search is a robust and accurate technique to map endoscopic video to CT. Endoscope Tracking is sensitive to erratic camera motion and local optima, but could be used in conjunction with anchor points found using Location Search.« less

  17. Development of innovative techniques for the endoscopic implantation and securing of a novel, wireless, miniature gastrostimulator (with videos)

    PubMed Central

    Deb, Sanchali; Tang, Shou-jiang; Abell, Thomas L.; McLawhorn, Tyler; Huang, Wen-Ding; Lahr, Christopher; To, S.D. Filip; Easter, Julie; Chiao, J.-C.

    2016-01-01

    Background Gastric stimulation via high-frequency, low-energy pulses can provide an effective treatment for gastric dysmotility; however, the current commercially available device requires surgical implantation for long-term stimulation and is powered by a nonrechargeable battery. Objective To test and describe endoscopic implantation techniques and testing of stimulation of a novel, wireless, batteryless, gastric electrical stimulation (GES) device. Design Endoscopic gastric implantation techniques were implemented, and in vivo gastric signals were recorded and measured in a non-survival swine model (n = 2; 50-kg animals). Intervention Five novel endoscopic gastric implantation techniques and stimulation of a novel, wireless, batteryless, GES device were tested on a non-survival swine model. Main Outcome Measurements Feasibility of 5 new endoscopic gastric implantation techniques of the novel, miniature, batteryless, wireless GES device while recording and measurement of in vivo gastric signals. Results All 5 of the novel endoscopic techniques permitted insertion and securing of the miniaturized gastrostimulator. By the help of these methods and miniaturization of the gastrostimulator, successful GES could be provided without any surgery. The metallic clip attachment was restricted to the mucosal surface, whereas the prototype tacks, prototype spring coils, percutaneous endoscopic gastrostomy wires/T-tag fasteners, and submucosal pocket endoscopic implantation methods attach the stimulator near transmurally or transmurally to the stomach. They allow more secure device attachment with optimal stimulation depth. Limitations Non-survival pig studies. Conclusion These 5 techniques have the potential to augment the utility of GES as a treatment alternative, to provide an important prototype for other dysmotility treatment paradigms, and to yield insights for new technological interfaces between non-invasiveness and surgery. PMID:22726478

  18. Use of a real-time viewer for endoscopic deployment of capsule endoscope in the pediatric population.

    PubMed

    Bass, Lee M; Misiewicz, Lawrence

    2012-11-01

    Wireless capsule endoscopy (WCE) is an increasingly used procedure for visualization of the small intestine. One challenge in pediatric WCE is the placement of the capsule in a population unable to swallow it for a variety of reasons. Here we present a novel use of the real-time (RT) viewer in the endoscopic deployment of the capsule endoscope. We performed a retrospective chart review on all WCE completed at the Children's Memorial Hospital from February 2010 to May 2011. Following a diagnostic upper endoscopy, the RT viewer was attached to the capsule recorder and image was noted before insertion. The endoscope and AdvanCE capsule delivery device were slowly advanced into duodenum while maintaining visualization on the RT viewer. A total of 17 patients who underwent a WCE with endoscopic placement were identified. They ranged in ages from 2 to 19 years. Thirteen patients required endoscopic placement because of the inability to swallow the capsule, whereas 4 were placed during a scheduled procedure to take advantage of sedation and airway protection. All of the 17 patients had successful deployment of the capsule into the duodenal lumen. In each case, the endoscopist was able to confirm capsule location in duodenum during scope withdrawal. There was no evidence of iatrogenic trauma or bleeding in any patient. There were 5 incomplete studies, a completion rate consistent with that described in the literature. The use of the RT viewer for endoscopic deployment of WCE is an effective technique to improve visualization of capsule placement in the pediatric population.

  19. Understanding nonlinear vibration behaviours in high-power ultrasonic surgical devices

    PubMed Central

    Mathieson, Andrew; Cardoni, Andrea; Cerisola, Niccolò; Lucas, Margaret

    2015-01-01

    Ultrasonic surgical devices are increasingly used in oral, craniofacial and maxillofacial surgery to cut mineralized tissue, offering the surgeon high accuracy with minimal risk to nerve and vessel tissue. Power ultrasonic devices operate in resonance, requiring their length to be a half-wavelength or multiple-half-wavelength. For bone surgery, devices based on a half-wavelength have seen considerable success, but longer multiple-half-wavelength endoscopic devices have recently been proposed to widen the range of surgeries. To provide context for these developments, some examples of surgical procedures and the associated designs of ultrasonic cutting tips are presented. However, multiple-half-wavelength components, typical of endoscopic devices, have greater potential to exhibit nonlinear dynamic behaviours that have a highly detrimental effect on device performance. Through experimental characterization of the dynamic behaviour of endoscopic devices, it is demonstrated how geometrical features influence nonlinear dynamic responses. Period doubling, a known route to chaotic behaviour, is shown to be significantly influenced by the cutting tip shape, whereas the cutting tip has only a limited effect on Duffing-like responses, particularly the shape of the hysteresis curve, which is important for device stability. These findings underpin design, aiming to pave the way for a new generation of ultrasonic endoscopic surgical devices. PMID:27547081

  20. Towards standardized assessment of endoscope optical performance: geometric distortion

    NASA Astrophysics Data System (ADS)

    Wang, Quanzeng; Desai, Viraj N.; Ngo, Ying Z.; Cheng, Wei-Chung; Pfefer, Joshua

    2013-12-01

    Technological advances in endoscopes, such as capsule, ultrathin and disposable devices, promise significant improvements in safety, clinical effectiveness and patient acceptance. Unfortunately, the industry lacks test methods for preclinical evaluation of key optical performance characteristics (OPCs) of endoscopic devices that are quantitative, objective and well-validated. As a result, it is difficult for researchers and developers to compare image quality and evaluate equivalence to, or improvement upon, prior technologies. While endoscope OPCs include resolution, field of view, and depth of field, among others, our focus in this paper is geometric image distortion. We reviewed specific test methods for distortion and then developed an objective, quantitative test method based on well-defined experimental and data processing steps to evaluate radial distortion in the full field of view of an endoscopic imaging system. Our measurements and analyses showed that a second-degree polynomial equation could well describe the radial distortion curve of a traditional endoscope. The distortion evaluation method was effective for correcting the image and can be used to explain other widely accepted evaluation methods such as picture height distortion. Development of consensus standards based on promising test methods for image quality assessment, such as the method studied here, will facilitate clinical implementation of innovative endoscopic devices.

  1. endoscope-i: an innovation in mobile endoscopic technology transforming the delivery of patient care in otolaryngology.

    PubMed

    Mistry, N; Coulson, C; George, A

    2017-11-01

    Digital and mobile device technology in healthcare is a growing market. The introduction of the endoscope-i, the world's first endoscopic mobile imaging system, allows the acquisition of high definition images of the ear, nose and throat (ENT). The system combines the e-i Pro camera app with a bespoke engineered endoscope-i adaptor which fits securely onto the iPhone or iPod touch. Endoscopic examination forms a salient aspect of the ENT work-up. The endoscope-i therefore provides a mobile and compact alternative to the existing bulky endoscopic systems currently in use which often restrict the clinician to the clinic setting. Areas covered: This article gives a detailed overview of the endoscope-i system together with its applications. A review and comparison of alternative devices on the market offering smartphone adapted endoscopic viewing systems is also presented. Expert commentary: The endoscope-i fulfils unmet needs by providing a compact, highly portable, simple to use endoscopic viewing system which is cost-effective and which makes use of smartphone technology most clinicians have in their pocket. The system allows real-time feedback to the patient and has the potential to transform the way that healthcare is delivered in ENT as well as having applications further afield.

  2. Endoscopic submucosal tunnel dissection of upper gastrointestinal submucosal tumors: A comparative study of hook knife vs hybrid knife.

    PubMed

    Zhou, Jie-Qiong; Tang, Xiao-Wei; Ren, Yu-Tang; Wei, Zheng-Jie; Huang, Si-Lin; Gao, Qiao-Ping; Zhang, Xiao-Feng; Yang, Jian-Feng; Gong, Wei; Jiang, Bo

    2017-03-14

    To compare the efficacy and safety of a hook knife (HO) with a hybrid knife (HK) during endoscopic submucosal tunnel dissection (ESTD) procedure. Between August 2012 and December 2015, the ESTD procedure was performed for 83 upper GI submucosal lesions, which originated from the muscularis propria layer identified by upper endoscopy and endoscopic ultrasonography. Of these, 34 lesions were treated by a HO, whereas 49 lesions were treated by a HK. Data regarding age, gender, presenting symptoms, tumor location and size, procedure time, complications, en bloc resection rate and others were analyzed and compared between the two groups. There were no significant differences in the age, gender, presenting symptoms and tumor location between the two groups. ESTD was successfully completed in all the patients, and no case was converted to laparoscopy. The mean procedure time was significantly shorter in the HK group than in the HO group (41.3 ± 20.3 min vs 57.2 ± 28.0 min, P = 0.004). The mean frequency of device exchange was 1.4 ± 0.6 in the HK group and significantly less than 3.3 ± 0.6 in the HO group ( P < 0.001). The differences in tumor size and histopathological diagnoses were not significant between the two groups ( P = 0.813, P = 0.363, respectively). Both groups had an equal en bloc resection rate and complete resection rate. Additionally, the complication rate was similar between the two groups ( P = 0.901). During the follow-up, no recurrence occurred in either group. We demonstrate for the first time that HO and HK do not differ in efficacy or safety, but HK reduces the frequency of device exchange and procedure time.

  3. Supportive techniques and devices for endoscopic submucosal dissection of gastric cancer.

    PubMed

    Sakurazawa, Nobuyuki; Kato, Shunji; Fujita, Itsuo; Kanazawa, Yoshikazu; Onodera, Hiroyuki; Uchida, Eiji

    2012-06-16

    The indications for endoscopic treatment have expanded in recent years, and relatively intestinal-type mucosal stomach carcinomas with a low potential for metastasis are now often resected en bloc by endoscopic submucosal dissection (ESD), even if they measure over 20 mm in size. However, ESD requires complex maneuvers, which entails a long operation time, and is often accompanied by complications such as bleeding and perforation. Many technical developments have been implemented to overcome these complications. The scope, cutting device, hemostasis device, and other supportive devices have been improved. However, even with these innovations, ESD remains a potentially complex procedure. One of the major difficulties is poor visualization of the submucosal layer resulting from the poor countertraction afforded during submucosal dissection. Recently, countertraction devices have been developed. In this paper, we introduce countertraction techniques and devices mainly for gastric cancer.

  4. Endoscopic therapy for weight loss: Gastroplasty, duodenal sleeves, intragastric balloons, and aspiration

    PubMed Central

    Kumar, Nitin

    2015-01-01

    A new paradigm in the treatment of obesity and metabolic disease is developing. The global obesity epidemic continues to expand despite the availability of diet and lifestyle counseling, pharmacologic therapy, and weight loss surgery. Endoscopic procedures have the potential to bridge the gap between medical therapy and surgery. Current primary endoscopic bariatric therapies can be classified as restrictive, bypass, space-occupying, or aspiration therapy. Restrictive procedures include the USGI Primary Obesity Surgery Endolumenal procedure, endoscopic sleeve gastroplasty using Apollo OverStitch, TransOral GAstroplasty, gastric volume reduction using the ACE stapler, and insertion of the TERIS restrictive device. Intestinal bypass has been reported using the EndoBarrier duodenal-jejunal bypass liner. A number of space-occupying devices have been studied or are in use, including intragastric balloons (Orbera, Reshape Duo, Heliosphere BAG, Obalon), Transpyloric Shuttle, and SatiSphere. The AspireAssist aspiration system has demonstrated efficacy. Finally, endoscopic revision of gastric bypass to address weight regain has been studied using Apollo OverStitch, the USGI Incisionless Operating Platform Revision Obesity Surgery Endolumenal procedure, Stomaphyx, and endoscopic sclerotherapy. Endoscopic therapies for weight loss are potentially reversible, repeatable, less invasive, and lower cost than various medical and surgical alternatives. Given the variety of devices under development, in clinical trials, and currently in use, patients will have multiple endoscopic options with greater efficacy than medical therapy, and with lower invasiveness and greater accessibility than surgery. PMID:26240686

  5. Endoscopic therapy for weight loss: Gastroplasty, duodenal sleeves, intragastric balloons, and aspiration.

    PubMed

    Kumar, Nitin

    2015-07-25

    A new paradigm in the treatment of obesity and metabolic disease is developing. The global obesity epidemic continues to expand despite the availability of diet and lifestyle counseling, pharmacologic therapy, and weight loss surgery. Endoscopic procedures have the potential to bridge the gap between medical therapy and surgery. Current primary endoscopic bariatric therapies can be classified as restrictive, bypass, space-occupying, or aspiration therapy. Restrictive procedures include the USGI Primary Obesity Surgery Endolumenal procedure, endoscopic sleeve gastroplasty using Apollo OverStitch, TransOral GAstroplasty, gastric volume reduction using the ACE stapler, and insertion of the TERIS restrictive device. Intestinal bypass has been reported using the EndoBarrier duodenal-jejunal bypass liner. A number of space-occupying devices have been studied or are in use, including intragastric balloons (Orbera, Reshape Duo, Heliosphere BAG, Obalon), Transpyloric Shuttle, and SatiSphere. The AspireAssist aspiration system has demonstrated efficacy. Finally, endoscopic revision of gastric bypass to address weight regain has been studied using Apollo OverStitch, the USGI Incisionless Operating Platform Revision Obesity Surgery Endolumenal procedure, Stomaphyx, and endoscopic sclerotherapy. Endoscopic therapies for weight loss are potentially reversible, repeatable, less invasive, and lower cost than various medical and surgical alternatives. Given the variety of devices under development, in clinical trials, and currently in use, patients will have multiple endoscopic options with greater efficacy than medical therapy, and with lower invasiveness and greater accessibility than surgery.

  6. Trial of a novel endoscopic tattooing biopsy forceps on animal model

    PubMed Central

    Si, Jian-Min; Sun, Lei-Min; Fan, Yu-Jing; Wang, Liang-Jing

    2005-01-01

    AIM: To tattoo gastric mucosa with a novel medical device which could be used to monitor and follow-up gastric mucosal lesions. METHODS: Combining endoscopic biopsy with sclerotherapy injection, we designed a new device that could perform biopsy and injection simultaneously. We performed endoscopies on a pig by using a novel endoscope tattoo biopsy forceps for 15 mo. At the same time, we used two-step method combining sclerotherapy injection needle with endoscopic biopsy. The acuity, inflammation and duration of endoscopy were compared between two methods. RESULTS: Compared with the old two-step method, although the inflammation induced by our new device was similar, the duration of procedure was markedly decreased and the acuity of tattooing was better than the old two-step method. All characteristics of the novel device complied with national safety guidelines. Follow-up gastroscopy after 15 mo showed the stained site with injection of 1:100 0.5 mL of India ink was still markedly visible with little inflammatory reaction. CONCLUSION: Endoscopic tattooing biopsy forceps can be widely used in monitoring precancerous lesions. Its safety and effectiveness has been established in animals. PMID:15793881

  7. 21 CFR 876.4300 - Endoscopic electrosurgical unit and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... Endoscopic electrosurgical unit and accessories. (a) Identification. An endoscopic electrosurgical unit and... device includes the electrosurgical generator, patient plate, electric biopsy forceps, electrode, flexible snare, electrosurgical alarm system, electrosurgical power supply unit, electrical clamp, self...

  8. A STERILIZATION STANDARD FOR ENDOSCOPES AND OTHER DIFFICULT TO CLEAN MEDICAL DEVICES

    EPA Science Inventory

    An array of difficult to clean devices are used for diagnostic and surgical procedures involving various degrees of invasiveness. These range from prophylaxis angles used for cleaning and polishing teeth to flexible fiberoptic endoscopes for surgical procedures that penetrate the...

  9. Haptic device for colonoscopy training simulator.

    PubMed

    Kwon, Jun Yong; Woo, Hyun Soo; Lee, Doo Yong

    2005-01-01

    A new 2-DOF haptic device for colonoscopy training simulator employing flexible endoscopes, is developed. The user operates the device in translational and roll directions. The developed folding guides of the device keep the endoscope tube straight. This helps transmit large decoupled forces of the colonoscopy simulation to the user. The device also includes a mechanism to detect jiggling motion of the scopes to allow users to practice this important skill of the colonoscopy. The device includes PD controller to compensate the inertia and friction effects. This provides the users with better transparent sensation of the simulation.

  10. Analysis of Preoperative Airway Examination with the CMOS Video Rhino-laryngoscope.

    PubMed

    Tsukamoto, Masanori; Hitosugi, Takashi; Yokoyama, Takeshi

    2017-05-01

    Endoscopy is one of the most useful clinical techniques in difficult airway management Comparing with the fibroptic endoscope, this compact device is easy to operate and can provide the clear image. In this study, we investigated its usefulness in the preoperative examination of endoscopy. Patients undergoing oral maxillofacial surgery were enrolled in this study. We performed preoperative airway examination by electronic endoscope (The CMOS video rhino-laryngoscope, KARL STORZ Endoscopy Japan, Tokyo). The system is composed of a videoendoscope, a compact video processor and a video recorder. In addition, the endoscope has a small color charge coupled device (CMOS) chip built into the tip of the endoscope. The outer diameter of the tip of this scope is 3.7 mm. In this study, electronic endoscope was used for preoperative airway examination in 7 patients. The preoperative airway examination with electronic endoscope was performed successfully in all the patients except one patient The patient had the symptoms such as nausea and vomiting at the examination. We could perform preoperative airway examination with excellent visualization and convenient recording of video sequence images with the CMOS video rhino-laryngoscope. It might be a especially useful device for the patients of difficult airways.

  11. Isocentric Navigation of Percutaneous Endoscopic Transforaminal Discectomy at the L5/S1 Level in Difficult Puncture Cases: A Technical Note.

    PubMed

    Fan, Guoxin; Wang, Teng; Hu, Shuo; Guan, Xiaofei; Gu, Xin; He, Shisheng

    2017-05-01

    Accurate puncture during percutaneous transforaminal endoscopic discectomy at the L5/S1 level in cases with high iliac crest and narrow foramen were difficult, even though the difficulties of foraminoplasty could be overcome by advanced instruments like reamers. The report aimed to describe an isocentric navigation technique with a definite pathway in difficult puncture cases at the L5/S1 level. Technical note. Difficult punctures were defined as over 10 punctures of the needle before obtaining an ideal puncture location by senior surgeons with experience of over 500 percutaneous endoscopic transforaminal discectomy (PETD) cases. A total of 124 punctures were recorded in 11 difficult puncture cases at the L5/S1 level. A definite pathway was created by an isocentric navigation theory, which was based on a surface locator and an arch-guided device. The surface locator was used to rapidly and accurately identify the puncture target with the recognition of the surrounding rods under fluoroscopy. The arch-guided device can ensure that the puncture target always remains at the center of a virtual sphere. We recorded the puncture times, fluoroscopy exposure times, radiation exposure time, operative time, visual analog scale (VAS) score, Japanese Orthopeadic Association (JOA) score, and patient satisfaction. The average puncture times were significantly reduced to 1.27 with the arch-guided device compared with conventional puncture methods (P < 0.05). The average operative time was 90.09 ± 11.00 minutes and the fluoroscopy times were 53.36 ± 5.85. The radiation exposure time was 50.91 ± 5.20 seconds. VAS score of leg and back pain, as well as JOA score, were all significantly improved after surgery (P < 0.05). The excellent and good rate of satisfaction was 90.91%. No major complications, including cerebral fluid leakage, surgical infection, and postoperative nerve root injury, were recorded in this small sample. This was a small-sample study with a short follow-up. The novel isocentric navigation technique with a definite pathway is practical and effective in reducing puncture times among difficult puncture cases at the L5/S1 level, which may contribute to the capacity of PETD at the L5/S1 level.

  12. Endoscopic submucosal dissection for removal of superficial gastrointestinal neoplasms: A technical review

    PubMed Central

    Matsui, Noriaki; Akahoshi, Kazuya; Nakamura, Kazuhiko; Ihara, Eikichi; Kita, Hiroto

    2012-01-01

    Endoscopic submucosal dissection (ESD) is now the most common endoscopic treatment in Japan for intramucosal gastrointestinal neoplasms (non-metastatic). ESD is an invasive endoscopic surgical procedure, requiring extensive knowledge, skill, and specialized equipment. ESD starts with evaluation of the lesion, as accurate assessment of the depth and margin of the lesion is essential. The devices and strategies used in ESD vary, depending on the nature of the lesion. Prior to the procedure, the operator must be knowledgeable about the treatment strategy(ies), the device(s) to use, the electrocautery machine settings, the substances to inject, and other aspects. In addition, the operator must be able to manage complications, should they arise, including immediate recognition of the complication(s) and its treatment. Finally, in case the ESD treatment is not successful, the operator should be prepared to apply alternative treatments. Thus, adequate knowledge and training are essential to successfully perform ESD. PMID:22523613

  13. Recent Development of Techniques and Devices in Colorectal Endoscopic Submucosal Dissection

    PubMed Central

    Mizutani, Hiroya; Ono, Satoshi; Ohki, Daisuke; Takeuchi, Chihiro; Yakabi, Seiichi; Kataoka, Yosuke; Saito, Itaru; Sakaguchi, Yoshiki; Minatsuki, Chihiro; Tsuji, Yosuke; Niimi, Keiko; Kodashima, Shinya; Yamamichi, Nobutake; Fujishiro, Mitsuhiro; Koike, Kazuhiko

    2017-01-01

    Colorectal endoscopic submucosal dissection (ESD) is now a well-established endoscopic treatment for early-stage colorectal neoplasms, especially in Asian countries, including Japan. Despite the spread of colorectal ESD, there are still situations in which achieving successful submucosal dissection is difficult. Various novel techniques and devices have been developed to overcome these difficulties, and past reports have shown that some of these strategies can be applied to colorectal ESD. We review several recent developments in the field. The techniques reviewed include the pocket creation method and traction methods and the devices reviewed include the overtube with balloon and electrosurgical knives with water-jet function. These improved techniques and devices can facilitate safer, more reliable ESDs and expand its applicability and acceptability all over the world. PMID:29207854

  14. Role of endoscopic retrograde cholangiopancreatography in the management of benign biliary strictures: What’s new?

    PubMed Central

    Ferreira, Rosa; Loureiro, Rui; Nunes, Nuno; Santos, António Alberto; Maio, Rui; Cravo, Marília; Duarte, Maria Antónia

    2016-01-01

    Benign biliary strictures comprise a heterogeneous group of diseases. The most common strictures amenable to endoscopic treatment are post-cholecystectomy, post-liver transplantation, related to primary sclerosing cholangitis and to chronic pancreatitis. Endoscopic treatment of benign biliary strictures is widely used as first line therapy, since it is effective, safe, noninvasive and repeatable. Endoscopic techniques currently used are dilation, multiple plastic stents insertion and fully covered self-expandable metal stents. The main indication for dilation alone is primary sclerosing cholangitis related strictures. In the vast majority of the remaining cases, temporary placement of multiple plastic stents with/without dilation is considered the treatment of choice. Although this approach is effective, it requires multiple endoscopic sessions due to the short duration of stent patency. Fully covered self-expandable metal stents appear as a good alternative to plastic stents, since they have an increased radial diameter, longer stent patency, easier insertion technique and similar efficacy. Recent advances in endoscopic technique and various devices have allowed successful treatment in most cases. The development of novel endoscopic techniques and devices is still ongoing. PMID:26962404

  15. Prevention of stone migration with the Accordion during endoscopic ureteral lithotripsy.

    PubMed

    Pagnani, Christopher J; El Akkad, Magdy; Bagley, Demetrius H

    2012-05-01

    Endoscopic lithotripsy is often prolonged secondary to the retrograde migration of calculous fragments. Various balloons, baskets, and other devices have been used to prevent this migration. Our purpose is to analyze the effect of the Accordion(®) on stone migration and overall efficiency during lithotripsy. We prospectively evaluated 21 patients with a total of 23 distal ureteral stones. Patients underwent lithotripsy using an endoscopic impact lithotriptor. The Accordion was randomly used in 11 of these 21 patients. Data were collected regarding stone migration, stone size, stone ablation, ureteral clearing, and lengths of time for various stages of each procedure. Patients who were treated with the Accordion device experienced significantly less retrograde migration during fragmentation (P=0.0064). When stone volume was taken into account (but not on a per stone basis), ablation and ureteral clearing were also expedited, and fewer lithotripter "hits" and basket "sweeps" were needed. The Accordion device is effective in preventing the migration of stone fragments during endoscopic ureteral lithotripsy. Our data suggest that this device may also increase efficiency of the fragmentation and clearance of ureteral calculi.

  16. Smartphone-Based Endoscope System for Advanced Point-of-Care Diagnostics: Feasibility Study

    PubMed Central

    Bae, Jung Kweon; Vavilin, Andrey; You, Joon S; Kim, Hyeongeun; Ryu, Seon Young; Jang, Jeong Hun

    2017-01-01

    Background Endoscopic technique is often applied for the diagnosis of diseases affecting internal organs and image-guidance of surgical procedures. Although the endoscope has become an indispensable tool in the clinic, its utility has been limited to medical offices or operating rooms because of the large size of its ancillary devices. In addition, the basic design and imaging capability of the system have remained relatively unchanged for decades. Objective The objective of this study was to develop a smartphone-based endoscope system capable of advanced endoscopic functionalities in a compact size and at an affordable cost and to demonstrate its feasibility of point-of-care through human subject imaging. Methods We developed and designed to set up a smartphone-based endoscope system, incorporating a portable light source, relay-lens, custom adapter, and homebuilt Android app. We attached three different types of existing rigid or flexible endoscopic probes to our system and captured the endoscopic images using the homebuilt app. Both smartphone-based endoscope system and commercialized clinical endoscope system were utilized to compare the imaging quality and performance. Connecting the head-mounted display (HMD) wirelessly, the smartphone-based endoscope system could superimpose an endoscopic image to real-world view. Results A total of 15 volunteers who were accepted into our study were captured using our smartphone-based endoscope system, as well as the commercialized clinical endoscope system. It was found that the imaging performance of our device had acceptable quality compared with that of the conventional endoscope system in the clinical setting. In addition, images captured from the HMD used in the smartphone-based endoscope system improved eye-hand coordination between the manipulating site and the smartphone screen, which in turn reduced spatial disorientation. Conclusions The performance of our endoscope system was evaluated against a commercial system in routine otolaryngology examinations. We also demonstrated and evaluated the feasibility of conducting endoscopic procedures through a custom HMD. PMID:28751302

  17. Gastric full-thickness suturing during EMR and for treatment of gastric-wall defects (with video).

    PubMed

    von Renteln, Daniel; Schmidt, Arthur; Riecken, Bettina; Caca, Karel

    2008-04-01

    The endoscopic full-thickness Plicator device was initially developed to provide an endoscopic treatment option for patients with GERD. Because the endoscopic full-thickness Plicator enables rapid and easy placement of transmural sutures, comparable with surgical sutures, we used the Plicator device for endoscopic treatment or prevention of GI-wall defects. To describe the outcomes and complications of endoscopic full-thickness suturing during EMR and for the treatment of gastric-wall defects. A report of 4 cases treated with the endoscopic full-thickness suturing between June 2006 and April 2007. A large tertiary-referral center. Four subjects received endoscopic full-thickness suturing. The subjects were women, with a mean age of 67 years. Of the 4 subjects, 3 received endoscopic full-thickness suturing during or after an EMR. One subject received endoscopic full-thickness suturing for treatment of a fistula. Primary outcome measurements were clinical procedural success and procedure-related adverse events. The mean time for endoscopic full-thickness suturing was 15 minutes. In all cases, GI-wall patency was restored or ensured, and no procedure-related complications occurred. All subjects responded well to endoscopic full-thickness suturing. The resection of one GI stromal tumor was incomplete. Because of the Plicator's 60F distal-end diameter, endoscopic full-thickness suturing could only be performed with the patient under midazolam and propofol sedation. The durable Plicator suture might compromise the endoscopic follow-up after EMR. The endoscopic full-thickness Plicator permits rapid and easy placement of transmural sutures and seems to be a safe and effective alternative to surgical intervention to restore GI-wall defects or to ensure GI-wall patency during EMR procedures.

  18. Endoscopic management of foreign bodies in the upper gastrointestinal tract: An analysis of 846 cases in China

    PubMed Central

    Yuan, Fangfang; Tang, Xiaowei; Gong, Wei; Su, Lei; Zhang, Yali

    2018-01-01

    Foreign body ingestion is a relatively common occurrence, which may lead to morbidity and mortality. The aim of the present study was to report the experience of management of upper gastrointestinal foreign bodies by endoscopy in a large center. All patients who presented at the Department of Gastroenterology at Nanfang Hospital (Guangzhou, China) with complaints regarding upper gastrointestinal (GI) foreign body ingestion from December 1987 to December 2013. Hospital medical charts and endoscopic records were examined to evaluate etiology, treatment, and outcomes for these patients. A total of 846 patients were enrolled in the present study, from which foreign bodies were detected in 737 (87.1%) patients via X-ray or endoscopy. The objects most frequently ingested were bones (n=395, 53.6%). The detected foreign bodies were predominantly located in the cervical esophagus (n=325, 44.1%). Endoscopic foreign body extraction was successful in 92.5% of cases, whereas surgery was required in 6 patients. The most frequently used endoscopic accessory devices were retrieval forceps (n=480, 65.1%). The complication rate was 6.9%, including mucosal laceration (n=10) and others, all of which were managed conservatively. Associated GI diseases were reported in 74 (10.0%) patients, including postesophagectomy (n=34) and others. In conclusion, the endoscopic procedure was safe and effective for the removal of foreign bodies from the upper gastrointestinal tract, with a high success rate and low complication rate. PMID:29434711

  19. Endoscopic full-thickness resection: Current status

    PubMed Central

    Schmidt, Arthur; Meier, Benjamin; Caca, Karel

    2015-01-01

    Conventional endoscopic resection techniques such as endoscopic mucosal resection or endoscopic submucosal dissection are powerful tools for treatment of gastrointestinal neoplasms. However, those techniques are restricted to superficial layers of the gastrointestinal wall. Endoscopic full-thickness resection (EFTR) is an evolving technique, which is just about to enter clinical routine. It is not only a powerful tool for diagnostic tissue acquisition but also has the potential to spare surgical therapy in selected patients. This review will give an overview about current EFTR techniques and devices. PMID:26309354

  20. Endoscopic full-thickness resection: Current status.

    PubMed

    Schmidt, Arthur; Meier, Benjamin; Caca, Karel

    2015-08-21

    Conventional endoscopic resection techniques such as endoscopic mucosal resection or endoscopic submucosal dissection are powerful tools for treatment of gastrointestinal neoplasms. However, those techniques are restricted to superficial layers of the gastrointestinal wall. Endoscopic full-thickness resection (EFTR) is an evolving technique, which is just about to enter clinical routine. It is not only a powerful tool for diagnostic tissue acquisition but also has the potential to spare surgical therapy in selected patients. This review will give an overview about current EFTR techniques and devices.

  1. [Design of Adjustable Magnetic Field Generating Device in the Capsule Endoscope Tracking System].

    PubMed

    Ruan, Chao; Guo, Xudong; Yang, Fei

    2015-08-01

    The capsule endoscope swallowed from the mouth into the digestive system can capture the images of important gastrointestinal tract regions. It can compensate for the blind spot of traditional endoscopic techniques. It enables inspection of the digestive system without discomfort or need for sedation. However, currently available clinical capsule endoscope has some limitations such as the diagnostic information being not able to correspond to the orientation in the body, since the doctor is unable to control the capsule motion and orientation. To solve the problem, it is significant to track the position and orientation of the capsule in the human body. This study presents an AC excitation wireless tracking method in the capsule endoscope, and the sensor embedded in the capsule can measure the magnetic field generated by excitation coil. And then the position and orientation of the capsule can be obtained by solving a magnetic field inverse problem. Since the magnetic field decays with distance dramatically, the dynamic range of the received signal spans three orders of magnitude, we designed an adjustable alternating magnetic field generating device. The device can adjust the strength of the alternating magnetic field automatically through the feedback signal from the sensor. The prototype experiment showed that the adjustable magnetic field generating device was feasible. It could realize the automatic adjustment of the magnetic field strength successfully, and improve the tracking accuracy.

  2. Endoscopic full-thickness resection of gastric subepithelial tumors: a single-center series.

    PubMed

    Schmidt, Arthur; Bauder, Markus; Riecken, Bettina; von Renteln, Daniel; Muehleisen, Helmut; Caca, Karel

    2015-02-01

    Endoscopic full-thickness resection of gastric subepithelial tumors with a full-thickness suturing device has been described as feasible in two small case series. The aim of this study was to evaluate the efficacy, safety, and clinical outcome of this resection technique. After 31 patients underwent endoscopic full-thickness resection, the data were analyzed retrospectively. Before snare resection, 1 to 3 full-thickness sutures were placed underneath each tumor with a device originally designed for endoscopic anti-reflux therapy. All tumors were resected successfully. Bleeding occurred in 12 patients (38.7 %); endoscopic hemostasis could be achieved in all cases. Perforation occurred in 3 patients (9.6 %), and all perforations could be managed endoscopically. Complete resection was histologically confirmed in 28 of 31 patients (90.3 %). Mean follow-up was 213 days (range, 1 - 1737), and no tumor recurrences were observed. Endoscopic full-thickness resection of gastric subepithelial tumors with the suturing technique described above is feasible and effective. After the resection of gastrointestinal stromal tumors (GISTs), we did not observe any recurrences during follow-up, indicating that endoscopic full-thickness resection may be an alternative to surgical resection for selected patients. © Georg Thieme Verlag KG Stuttgart · New York.

  3. Risk of transmission of carbapenem-resistant Enterobacteriaceae and related “superbugs” during gastrointestinal endoscopy

    PubMed Central

    Muscarella, Lawrence F

    2014-01-01

    To evaluate the risk of transmission of carbapenem-resistant Enterobacteriaceae (CRE) and their related superbugs during gastrointestinal (GI) endoscopy. Reports of outbreaks linked to GI endoscopes contaminated with different types of infectious agents, including CRE and their related superbugs, were reviewed. Published during the past 30 years, both prior to and since CRE’s emergence, these reports were obtained by searching the peer-reviewed medical literature (via the United States National Library of Medicine’s “MEDLINE” database); the Food and Drug Administration’s Manufacturer and User Facility Device Experience database, or “MAUDE”; and the Internet (via Google’s search engine). This review focused on an outbreak of CRE in 2013 following the GI endoscopic procedure known as endoscopic retrograde cholangiopancreatography, or ERCP, performed at “Hospital X” located in the suburbs of Chicago (IL; United States). Part of the largest outbreak of CRE in United States history, the infection and colonization of 10 and 28 of this hospital’s patients, respectively, received considerable media attention and was also investigated by the Centers for Disease Control and Prevention (CDC), which published a report about this outbreak in Morbidity and Mortality Weekly Report (MMWR), in 2014. This report, along with the results of an independent inspection of Hospital X’s infection control practices following this CRE outbreak, were also reviewed. While this article focuses primarily on the prevention of transmissions of CRE and their related superbugs in the GI endoscopic setting, some of its discussion and recommendations may also apply to other healthcare settings, to other types of flexible endoscopes, and to other types of transmissible infectious agents. This review found that GI endoscopy is an important risk factor for the transmission of CRE and their related superbugs, having been recently associated with patient morbidity and mortality following ERCP. The CDC reported in MMWR that the type of GI endoscope, known as an ERCP endoscope, that Hospital X used to perform ERCP in 2013 on the 38 patients who became infected or colonized with CRE might be particularly challenging to clean and disinfect, because of the complexity of its physical design. If performed in strict accordance with the endoscope manufacturer’s labeling, supplemented as needed with professional organizations’ published guidelines, however, current practices for reprocessing GI endoscopes, which include high-level disinfection, are reportedly adequate for the prevention of transmission of CRE and their related superbugs. Several recommendations are provided to prevent CRE transmissions in the healthcare setting. CRE transmissions are not limited to contaminated GI endoscopes and also have been linked to other reusable flexible endoscopic instrumentation, including bronchoscopes and cystoscopes. In conclusion, contaminated GI endoscopes, particularly those used during ERCP, have been causally linked to outbreaks of CRE and their related superbugs, with associated patient morbidity and mortality. Thorough reprocessing of these complex reusable instruments is necessary to prevent disease transmission and ensure patient safety during GI endoscopy. Enhanced training and monitoring of reprocessing staffers to verify the proper cleaning and brushing of GI endoscopes, especially the area around, behind and near the forceps elevator located at the distal end of the ERCP endoscope, are recommended. If the ERCP endoscope features a narrow and exposed channel that houses a wire connecting the GI endoscope’s control head to this forceps elevator, then this channel’s complete reprocessing, including its flushing with a detergent using a procedure validated for effectiveness, is also emphasized. PMID:25324917

  4. Wireless Acoustic-Surface Actuators for Miniaturized Endoscopes.

    PubMed

    Qiu, Tian; Adams, Fabian; Palagi, Stefano; Melde, Kai; Mark, Andrew; Wetterauer, Ulrich; Miernik, Arkadiusz; Fischer, Peer

    2017-12-13

    Endoscopy enables minimally invasive procedures in many medical fields, such as urology. However, current endoscopes are normally cable-driven, which limits their dexterity and makes them hard to miniaturize. Indeed, current urological endoscopes have an outer diameter of about 3 mm and still only possess one bending degree-of-freedom. In this article, we report a novel wireless actuation mechanism that increases the dexterity and that permits the miniaturization of a urological endoscope. The novel actuator consists of thin active surfaces that can be readily attached to any device and are wirelessly powered by ultrasound. The surfaces consist of two-dimensional arrays of microbubbles, which oscillate under ultrasound excitation and thereby generate an acoustic streaming force. Bubbles of different sizes are addressed by their unique resonance frequency, thus multiple degrees-of-freedom can readily be incorporated. Two active miniaturized devices (with a side length of around 1 mm) are demonstrated: a miniaturized mechanical arm that realizes two degrees-of-freedom, and a flexible endoscope prototype equipped with a camera at the tip. With the flexible endoscope, an active endoscopic examination is successfully performed in a rabbit bladder. The results show the potential medical applicability of surface actuators wirelessly powered by ultrasound penetrating through biological tissues.

  5. Wireless Acoustic-Surface Actuators for Miniaturized Endoscopes

    PubMed Central

    2017-01-01

    Endoscopy enables minimally invasive procedures in many medical fields, such as urology. However, current endoscopes are normally cable-driven, which limits their dexterity and makes them hard to miniaturize. Indeed, current urological endoscopes have an outer diameter of about 3 mm and still only possess one bending degree-of-freedom. In this article, we report a novel wireless actuation mechanism that increases the dexterity and that permits the miniaturization of a urological endoscope. The novel actuator consists of thin active surfaces that can be readily attached to any device and are wirelessly powered by ultrasound. The surfaces consist of two-dimensional arrays of microbubbles, which oscillate under ultrasound excitation and thereby generate an acoustic streaming force. Bubbles of different sizes are addressed by their unique resonance frequency, thus multiple degrees-of-freedom can readily be incorporated. Two active miniaturized devices (with a side length of around 1 mm) are demonstrated: a miniaturized mechanical arm that realizes two degrees-of-freedom, and a flexible endoscope prototype equipped with a camera at the tip. With the flexible endoscope, an active endoscopic examination is successfully performed in a rabbit bladder. The results show the potential medical applicability of surface actuators wirelessly powered by ultrasound penetrating through biological tissues. PMID:29148713

  6. Miniature Wireless BioSensor for Remote Endoscopic Monitoring

    NASA Astrophysics Data System (ADS)

    Nemiroski, Alex; Brown, Keith; Issadore, David; Westervelt, Robert; Thompson, Chris; Obstein, Keith; Laine, Michael

    2009-03-01

    We have built a miniature wireless biosensor with fluorescence detection capability that explores the miniaturization limit for a self-powered sensor device assembled from the latest off-the-shelf technology. The device is intended as a remote medical sensor to be inserted endoscopically and remainin a patient's gastrointestinal tract for a period of weeks, recording and transmitting data as necessary. A sensing network may be formed by using multiple such devices within the patient, routing information to an external receiver that communicates through existing mobilephone networks to relay data remotely. By using a monolithic IC chip with integrated processor, memory, and 2.4 GHz radio,combined with a photonic sensor and miniature battery, we have developed a fully functional computing device in a form factorcompliantwith insertion through the narrowest endoscopic channels (less than 3mm x 3mm x 20mm). We envision similar devices with various types of sensors to be used in many different areas of the human body.

  7. Catheter guided by optical coherence domain reflectometry

    DOEpatents

    Everett, Matthew; Colston, Billy W.; Da Silva, Luiz B.; Matthews, Dennis

    2002-01-01

    A guidance and viewing system based on multiplexed optical coherence domain reflectometry is incorporated into a catheter, endoscope, or other medical device to measure the location, thickness, and structure of the arterial walls or other intra-cavity regions at discrete points on the medical device during minimally invasive medical procedures. The information will be used both to guide the device through the body and to evaluate the tissue through which the device is being passed. Multiple optical fibers are situated along the circumference of the device. Light from the distal end of each fiber is directed onto the interior cavity walls via small diameter optics (such as gradient index lenses and mirrored corner cubes). Both forward viewing and side viewing fibers can be included. The light reflected or scattered from the cavity walls is then collected by the fibers and multiplexed at the proximal end to the sample arm of an optical low coherence reflectometer. The system may also be implemented in a nonmedical inspection device.

  8. Implemented a wireless communication system for VGA capsule endoscope.

    PubMed

    Moon, Yeon-Kwan; Lee, Jyung Hyun; Park, Hee-Joon; Cho, Jin-Ho; Choi, Hyun-Chul

    2014-01-01

    Recently, several medical devices that use wireless communication are under development. In this paper, the small size frequency shift keying (FSK) transmitter and a monofilar antenna for the capsule endoscope, enabling the medical device to transmit VGA-size images of the intestine. To verify the functionality of the proposed wireless communication system, computer simulations and animal experiments were performed with the implemented capsule endoscope that includes the proposed wireless communication system. Several fundamental experiments are carried out using the implemented transmitter and antenna, and animal in-vivo experiments were performed to verify VGA image transmission.

  9. Use of an Amplatzer Device for Endoscopic Closure of a Large Bronchopleural Fistula following Lobectomy for a Stage I Squamous Cell Carcinoma.

    PubMed

    Ottevaere, A; Slabbynck, H; Vermeersch, P; Rogiers, P; Galdermans, D; De Droogh, E; Bedert, L

    2013-01-01

    Bronchopleural fistulas can occur as a rare but severe complication after pulmonary resection. Established guidelines for the proper treatment of patients with bronchopleural fistulas do not exist. Apart from attempts to close the fistula, emphasis is placed on preventive measures, early treatment with antibiotics, drainage of the empyema and aggressive nutritional and rehabilitative support. For inoperable patients, endoscopic procedures are the only therapeutic option. Unfortunately, large (>8 mm) or central bronchopleural fistulas are usually not suitable for such endoscopic management. Recently, some groups have published a few case reports about a novel technique for the endobronchial closure of bronchopleural fistulas, using an Amplatzer device, originally designed for transcatheter closure of cardiac septal defects. We applied the same technique as a life-saving treatment in a ventilated patient who was considered inoperable due to a high oxygen need. The operation was successful. The patient could be weaned from ventilation and was eventually discharged from the hospital to a rehabilitation facility several weeks after the insertion of the device. Until now, endoscopic techniques have only been useful for the treatment of small, peripheral, bronchopleural fistulas and even then only as a bridge to surgery in high-risk surgical patients. In this case report, we demonstrate that the use of an Amplatzer device can expand the importance of endoscopic techniques in the treatment of bronchopleural fistulas. An Amplatzer device, for endobronchial closure, can indeed be administered for large and central bronchopleural fistulas. Moreover, it can be considered as a definite alternative to surgery in inoperable patients.

  10. Endoscopic removal of over-the-scope clips: Clinical experience with a bipolar cutting device

    PubMed Central

    Meier, Benjamin; Caca, Karel; Schmidt, Arthur

    2016-01-01

    Background Over-the-scope clips (OTSCs) are increasingly used for the closure of perforations/fistulae, hemostasis and endoscopic full-thickness resection (FTRD system). When OTSC-associated complications occur or re-therapy at the OTSC site is needed, OTSC removal may be indicated. An experimental study in an animal model and a case series have shown good results for OTSC removal with a bipolar cutting device. We present a larger clinical study using this device. Methods Data of all consecutive patients with indication for OTSC removal were collected and analyzed retrospectively. OTSCs were cut at two opposing sites using a bipolar grasping device to apply short direct current impulses. OTSC fragments were extracted with a standard forceps and a cap at the tip of the endoscope to avoid tissue damage. Results Between December 2012 and February 2016 a total of 42 OTSC removals in the upper (n = 25) and lower (n = 17) gastrointestinal tract have been performed at our department. Overall technical success, defined as cutting the OTSC at two opposing sites and extraction of both fragments, was achieved in 92.9% (39/42) of all cases. Successful fragmentation of the OTSC was achieved in 97.6% (41/42). Minor bleedings were rare and could be managed endoscopically in all cases. There were no perforations and no major or delayed bleedings. Conclusion Endoscopic OTSC removal with a bipolar cutting device is feasible, effective and safe. This technique can be applied in the upper and lower gastrointestinal tract. PMID:28588877

  11. Usefulness of a Flexible Port for Natural Orifice Transluminal Endoscopic Surgery by the Transrectal and Transvaginal Routes

    PubMed Central

    Ohdaira, Takeshi; Ikeda, Keiichi; Tajiri, Hisao; Yasuda, Yoshikazu; Hashizume, Makoto

    2010-01-01

    We developed a flexible port for NOTES which allows the use of conventional forceps for laparoscope-assisted surgery without change. The port is not affected by the location of the through hole in the gastrointestinal tract or vagina which elicits a problem in conventional NOTES, and its length can be adjusted during surgery by cutting the port itself. The port is made of polymer resin with a low friction coefficient. Furthermore, the port walls have a square wave structure which contributes to (1) the prevention of devices, for example, endoscope, from getting stuck at the time of insertion and retrieval, (2) the prevention of port slippage in the surgical opening for port insertion, (3) the prevention of unexpected port removal, (4) the prevention of port bore deformation, and (5) the improvement of port flexibility in the longitudinal direction. We validated the insertion and retrieval capacities of commercially available forceps for laparoscope-assisted surgery and power devices. Furthermore, we used the flexible port to conduct cholecystectomy and partial gastrectomy. We could confirm that the selection of the flexible port diameter according to the device type allowed the smooth insertion and retrieval of the device and that the port produced no air leakage. We affirmed that it is possible to conduct surgery by the cross or parallel method similarly to single port surgery. We considered that the flexible port has a potential of becoming a revolutionary port in NOTES. PMID:20508827

  12. Confocal Light Absorption and Scattering Spectroscopic (CLASS) imaging: From cancer detection to sub-cellular function

    NASA Astrophysics Data System (ADS)

    Qiu, Le

    Light scattering spectroscopy (LSS), an optical technique that relates the spectroscopic properties of light elastically scattered by small particles to their size, refractive index and shape, has been recently successfully employed for sensing morphological and biochemical properties of epithelial tissues and cells in vivo. LSS does not require exogenous markers, is non-invasive, and, due to its multispectral nature, can sense biological structures well beyond the diffraction limit. All that makes LSS be a very good candidate to be used both in clinical medicine for in vivo detection of disease and in cell biology to monitor cell function on the organelle scale. Recently we developed two LSS-based imaging modalities: clinical Polarized LSS (PLSS) Endoscopic Technique for locating early pre-cancerous changes in GI tract and Confocal Light Absorption and Scattering Spectroscopic (CLASS) Microscopy for studying cells in vivo without exogenous markers. One important application of the clinical PLSS endoscopic instrument, a noncontact scanning imaging device compatible with the standard clinical endoscopes and capable of detecting dysplastic changes, is to serve as a guide for biopsy in Barrett's esophagus (BE). The instrument detects parallel and perpendicular components of the polarized light, backscattered from epithelial tissues, and determines characteristics of epithelial nuclei from the residual spectra. It also can find tissue oxygenation, hemoglobin content and other properties from the diffuse light component. By rapidly scanning esophagus the PLSS endoscopic instrument makes sure the entire BE portion is scanned and examined for the presence of dysplasia. CLASS microscopy, on the other hand, combines principles of light scattering spectroscopy (LSS) with confocal microscopy. Its main purpose is to image cells on organelle scale in vivo without the use of exogenous labels which may affect the cell function. The confocal geometry selects specific region and images are obtained by scanning the confocal volume across the sample. The new beam scanning CLASS microscope is a significant improvement over the previous proof-of-principle device. With this new device we have already performed experiments to monitor morphological changes in cells during apoptosis, differentiated fetal from maternal nucleated red blood cells, and detected plasmon scattering spectra of single gold nanorod.

  13. High-level disinfection of gastrointestinal endoscope reprocessing

    PubMed Central

    Chiu, King-Wah; Lu, Lung-Sheng; Chiou, Shue-Shian

    2015-01-01

    High level disinfection (HLD) of the gastrointestinal (GI) endoscope is not simply a slogan, but rather is a form of experimental monitoring-based medicine. By definition, GI endoscopy is a semicritical medical device. Hence, such medical devices require major quality assurance for disinfection. And because many of these items are temperature sensitive, low-temperature chemical methods, such as liquid chemical germicide, must be used rather than steam sterilization. In summarizing guidelines for infection prevention and control for GI endoscopy, there are three important steps that must be highlighted: manual washing, HLD with automated endoscope reprocessor, and drying. Strict adherence to current guidelines is required because compared to any other medical device, the GI endoscope is associated with more outbreaks linked to inadequate cleaning or disinfecting during HLD. Both experimental evaluation on the surveillance bacterial cultures and in-use clinical results have shown that, the monitoring of the stringent processes to prevent and control infection is an essential component of the broader strategy to ensure the delivery of safe endoscopy services, because endoscope reprocessing is a multistep procedure involving numerous factors that can interfere with its efficacy. Based on our years of experience in the surveillance of culture monitoring of endoscopic reprocessing, we aim in this study to carefully describe what details require attention in the GI endoscopy disinfection and to share our experience so that patients can be provided with high quality and safe medical practices. Quality management encompasses all aspects of pre- and post-procedural care including the efficiency of the endoscopy unit and reprocessing area, as well as the endoscopic procedure itself. PMID:25699232

  14. Transvaginal endoscopic partial gastrectomy in porcine models: the role of an extra endoscope for gastric control.

    PubMed

    Nakajima, Kiyokazu; Takahashi, Tsuyoshi; Souma, Yoshihito; Shinzaki, Shinichiro; Yamada, Takuya; Yoshio, Toshiyuki; Nishida, Toshirou

    2008-12-01

    Transvaginal natural orifice translumenal endoscopic surgery (NOTES) gastrectomy is technically challenging, because wide perigastric dissection under appropriate tissue triangulation is unfeasible with current endoscopic instruments alone. The aim of this study was to investigate the feasibility of transvaginal NOTES gastrectomy with the use of an extra endoscope as a retracting device of the stomach. This acute in vivo feasibility study was performed under the approval of the Institutional Animal Care and Use Committee (IACUC). Four female 40-kg pigs received general anesthesia and underwent transvaginal endoscopic partial gastrectomy. Under laparoscopic guidance, the uterus was fixed anteriorly and transvaginal access was established in a standard fashion. The perigastric ligaments were dissected with needle knife/insulation-tipped electrosurgical knife (IT) via transvaginally placed double-channel endoscope. This step was assisted with the second, CO(2)-insufflating endoscope advanced in the stomach (i.e., so-called endoscopic gastric control). A linear stapling device with a flexible shaft was then passed transvaginally, and the anterior gastric wall was partially resected. The specimen was isolated and retrieved through the vagina. Concluding endoscopy was carried out to confirm the absence of mucosal damage due to endoscopic gastric control. This was further confirmed at necropsy immediately after sacrifice. All animals underwent successful transvaginal NOTES gastrectomy. Endoscopic gastric control greatly facilitated perigastric dissection by providing appropriate tissue countertraction on the ligaments. Use of transabdominal (laparoscopic) graspers was thus minimized. There were no intraoperative complications directly related to use of the primary (transvaginal) endoscope or the additional (gastric) endoscope. Distention of downstream bowel after gastric insufflation was minimal with CO(2). No major injuries were noted on gastric mucosa at postmortem investigations. Transvaginal NOTES partial gastrectomy is feasible in porcine models. Use of an extra endoscope to retract the stomach is effective to minimize transabdominal assistance. Further studies on human subjects are necessary to establish this as a safe and attractive ancillary technique in NOTES.

  15. Significant Improvement of Puncture Accuracy and Fluoroscopy Reduction in Percutaneous Transforaminal Endoscopic Discectomy With Novel Lumbar Location System: Preliminary Report of Prospective Hello Study.

    PubMed

    Fan, Guoxin; Guan, Xiaofei; Zhang, Hailong; Wu, Xinbo; Gu, Xin; Gu, Guangfei; Fan, Yunshan; He, Shisheng

    2015-12-01

    Prospective nonrandomized control study.The study aimed to investigate the implication of the HE's Lumbar LOcation (HELLO) system in improving the puncture accuracy and reducing fluoroscopy in percutaneous transforaminal endoscopic discectomy (PTED).Percutaneous transforaminal endoscopic discectomy is one of the most popular minimally invasive spine surgeries that heavily depend on repeated fluoroscopy. Increased fluoroscopy will induce higher radiation exposure to surgeons and patients. Accurate puncture in PTED can be achieved by accurate preoperative location and definite trajectory.The HELLO system mainly consists of self-made surface locator and puncture-assisted device. The surface locator was used to identify the exact puncture target and the puncture-assisted device was used to optimize the puncture trajectory. Patients who had single L4/5 or L5/S1 lumbar intervertebral disc herniation and underwent PTED were included the study. Patients receiving the HELLO system were assigned in Group A, and those taking conventional method were assigned in Group B. Study primary endpoint was puncture times and fluoroscopic times, and the secondary endpoint was location time and operation time.A total of 62 patients who received PTED were included in this study. The average age was 45.35 ± 8.70 years in Group A and 46.61 ± 7.84 years in Group B (P = 0.552). There were no significant differences in gender, body mass index, conservative time, and surgical segment between the 2 groups (P > 0.05). The puncture times were 1.19 ± 0.48 in Group A and 6.03 ± 1.87 in Group B (P < 0.001). The fluoroscopic times were 14.03 ± 2.54 in Group A and 25.19 ± 4.28 in Group B (P < 0.001). The preoperative location time was 4.67 ± 1.41 minutes in Group A and 6.98 ± 0.94 minutes in Group B (P < 0.001). The operation time was 79.42 ± 10.15 minutes in Group A and 89.65 ± 14.06 minutes in Group B (P = 0.002). The hospital stay was 2.77 ± 0.95 days in Group A and 2.87 ± 1.02 days in Group B (P = 0.702). There were no significant differences in the complication rate between the 2 groups (P = 0.386).The highlight of HELLO system is accurate preoperative location and definite trajectory. This preliminary report indicated that the HELLO system significantly improves the puncture accuracy of PTED and reduces the fluoroscopic times, preoperative location time, as well as operation time. (ChiCTR-ICR-15006730).

  16. Novel use of an ultrasonic bone-cutting device for endoscopic-assisted craniosynostosis surgery.

    PubMed

    Chaichana, Kaisorn L; Jallo, George I; Dorafshar, Amir H; Ahn, Edward S

    2013-07-01

    Endoscopic-assisted craniosynostosis surgery is associated with less blood loss and shorter operative times as compared to open surgery. However, in infants who have low circulating blood volumes, the endoscopic approach is still associated with significant blood loss. A major source of blood loss is the bone that is cut during surgery. We discuss the novel use of an ultrasonic bone-cutting device for craniosynostosis surgery, which decreases bone bleeding. This device, which has primarily only been used for spine and skull base surgery, may help reduce blood loss in these infants. All patients with single suture craniosynostosis who were operated on with the use of an ultrasonic bone-cutting device were identified. The information retrospectively recorded from patient charts included patient age, suture involved, blood loss, operative times, complications, preoperative hemoglobin, postoperative hemoglobin, length of hospital stay, and follow-up times. Thirteen patients (12 males, 1 female) underwent surgery with an ultrasonic bone-cutting device during the reviewed period. The average age (±standard deviation) of the patients was 11.8 (±1.6) weeks. Four patients had metopic synostosis and nine patients had sagittal synostosis. The average surgery time was 84 (±13) min. The median (interquartile range) blood loss was 20 (10-70) cc. No patients required blood transfusions. Three patients had dural tears. We demonstrate the novel use of an ultrasonic bone-cutting device for endoscopic-assisted craniosynostosis surgery. This device limited blood loss while maintaining short operative times for infants with low circulating blood volumes.

  17. Image-guided intervention in the human bile duct using scanning fiber endoscope system

    NASA Astrophysics Data System (ADS)

    Seibel, Eric J.; Jo, Javier A.; Melville, C. David; Johnston, Richard S.; Naumann, Christopher R.; Saunders, Michael D.

    2012-01-01

    Bile duct cancers are increasing in frequency while being difficult to diagnose. Currently available endoscopic imaging devices used in the biliary tree are low resolution with poor image quality, leading to inadequate evaluation of indeterminate biliary strictures. However, a new ultrathin and flexible cholangioscope system has been successfully demonstrated in a human subject. This mini-cholangioscope system uses a scanning fiber endoscope (SFE) as a forward-imaging guidewire, dimensions of 1.2-mm diameter and 3-m length. Full color video (500-line resolution at 30Hz) is the standard SFE imaging mode using spiral scanning of red, green, and blue laser light at low power. Image-guided operation of the biopsy forceps was demonstrated in healthy human bile ducts with and without saline flushing. The laser-based video imaging can be switched to various modes to enhance tissue markers of disease, such as widefield fluorescence and enhanced spectral imaging. In parallel work, biochemical discrimination of tissue health in pig bile duct has been accomplished using fiberoptic delivery of pulsed UV illumination and time-resolved autofluorescence spectroscopic measurements. Implementation of time-resolved fluorescence spectroscopy for biochemical assessment of the bile duct wall is being done through a secondary endoscopic channel. Preliminary results indicate that adequate SNR levels (> 30 dB) can be achieved through a 50 micron fiber, which could serve as an optical biopsy probe. The SFE is an ideal mini-cholangioscope for integration of both tissue and molecular specific image contrast in the future. This will provide the physician with unprecedented abilities to target biopsy locations and perform endoscopically-guided therapies.

  18. Real-time ultrasound-guided endoscopic surgery for putaminal hemorrhage.

    PubMed

    Sadahiro, Hirokazu; Nomura, Sadahiro; Goto, Hisaharu; Sugimoto, Kazutaka; Inamura, Akinori; Fujiyama, Yuichi; Yamane, Akiko; Oku, Takayuki; Shinoyama, Mizuya; Suzuki, Michiyasu

    2015-11-01

    Endoscopic surgery plays a significant role in the treatment of intracerebral hemorrhage. However, the residual hematoma cannot be measured intraoperatively from the endoscopic view, and it is difficult to determine the precise location of the endoscope within the hematoma cavity. The authors attempted to develop real-time ultrasound-guided endoscopic surgery using a bur-hole-type probe. From November 2012 to March 2014, patients with hypertensive putaminal hemorrhage who underwent endoscopic hematoma removal were enrolled in this study. Real-time ultrasound guidance was performed with a bur-hole-type probe that was advanced via a second bur hole, which was placed in the temporal region. Ultrasound was used to guide insertion of the endoscope sheath as well as to provide information regarding the location of the hematoma during surgical evacuation. Finally, the cavity was irrigated with artificial cerebrospinal fluid and was observed as a low-echoic space, which facilitated detection of residual hematoma. Ten patients with putaminal hemorrhage>30 cm3 were included in this study. Their mean age (±SD) was 60.9±8.6 years, and the mean preoperative hematoma volume was 65.2±37.1 cm3. The mean percentage of hematoma that was evacuated was 96%±3%. None of the patients exhibited rebleeding after surgery. This navigation method was effective in demonstrating both the real-time location of the endoscope and real-time viewing of the residual hematoma. Use of ultrasound guidance minimized the occurrence of brain injury due to hematoma evacuation.

  19. Experimental application of pulsed laser-induced water jet for endoscopic submucosal dissection: mechanical investigation and preliminary experiment in swine.

    PubMed

    Sato, Chiaki; Nakano, Toru; Nakagawa, Atsuhiro; Yamada, Masato; Yamamoto, Hiroaki; Kamei, Takashi; Miyata, Go; Sato, Akira; Fujishima, Fumiyoshi; Nakai, Masaaki; Niinomi, Mitsuo; Takayama, Kazuyoshi; Tominaga, Teiji; Satomi, Susumu

    2013-05-01

    A current drawback of endoscopic submucosal dissection (ESD) for early-stage gastrointestinal tumors is the lack of instruments that can safely assist with this procedure. We have developed a pulsed jet device that can be incorporated into a gastrointestinal endoscope. Here, we investigated the mechanical profile of the pulsed jet device and demonstrated the usefulness of this instrument in esophageal ESD in swine. The device comprises a 5-Fr catheter, a 14-mm long stainless steel tube for generating the pulsed water jet, a nozzle and an optical quartz fiber. The pulsed water jet was generated at pulse rates of 3 Hz by irradiating the physiological saline (4°C) within the stainless steel tube with an holmium-doped yttrium-aluminum-garnet (Ho:YAG) laser at 1.1 J/pulse. Mechanical characteristics were evaluated using a force meter. The device was used only for the part of submucosal dissection in the swine ESD model. Tissues removed using the pulsed jet device and a conventional electrocautery device, and the esophagus, were histologically examined to assess thermal damage. The peak impact force was observed at a stand-off distance of 40 mm (1.1 J/pulse). ESD using the pulsed jet device was successful, as the tissue specimens showed precise dissection of the submucosal layer. The extent of thermal injury was significantly lower in the dissected bed using the pulsed jet device. The results showed that the present endoscopic pulsed jet system is a useful alternative for a safe ESD with minimum tissue injury. © 2012 The Authors. Digestive Endoscopy © 2012 Japan Gastroenterological Endoscopy Society.

  20. Endoscopic management of pancreatic pseudocysts at atypical locations.

    PubMed

    Bhasin, Deepak Kumar; Rana, Surinder Singh; Nanda, Mohit; Chandail, Vijant Singh; Masoodi, Ibrahim; Kang, Mandeep; Kalra, Navin; Sinha, Saroj Kant; Nagi, Birinder; Singh, Kartar

    2010-05-01

    There is paucity of data on endoscopic management of pseudocysts at atypical locations. We evaluated the efficacy of endoscopic transpapillary nasopancreatic drain (NPD) placement in the management of pseudocysts of pancreas at atypical locations. Eleven patients with pseudocysts at atypical locations were treated with attempted endoscopic transpapillary nasopancreatic drainage. On endoscopic retrograde pancreatography (ERP), a 5-F NPD was placed across/near the site of duct disruption. Three patients each had mediastinal, intrahepatic, and intra/perisplenic pseudocysts and one patient each had renal and pelvic pseudocyst. Nine patients had chronic pancreatitis whereas two patients had acute pancreatitis. The size of the pseudocysts ranged from 2 to 15 cm. On ERP, the site of ductal disruption was in the body of pancreas in five patients (45.4%), and tail of pancreas in six patients (54.6%). All the patients had partial disruption of pancreatic duct. The NPD was successfully placed across the disruption in 10 of the 11 patients (90.9%) and pseudocysts resolved in 4-8 weeks. One of the patients developed fever, 5 days after the procedure, which was successfully treated by intravenous antibiotics. In another patient, NPD became blocked 12 days after the procedure and was successfully opened by aspiration. The NPD slipped out in one of the patient with splenic pseudocyst and was replaced with a stent. There was no recurrence of symptoms or pseudocysts during follow-up of 3-70 months. Pancreatic pseudocysts at atypical locations with ductal communication and partial ductal disruption that is bridged by NPD can also be effectively treated with endoscopic transpapillary NPD placement.

  1. Endoscopic repair of an injured internal carotid artery utilizing femoral endovascular closure devices.

    PubMed

    Van Rompaey, Jason; Bowers, Greg; Radhakrishnan, Jay; Panizza, Benedict; Solares, C Arturo

    2014-06-01

    Injury to the internal carotid artery is a feared complication of endoscopic endonasal surgery of the skull base. Such an event, although rare, is associated with high morbidity and mortality. Even if bleeding is controlled, permanent neurological defects frequently persist. Many techniques have been developed to manage internal carotid artery rupture with varying degrees of success. The purpose of this study was to explore endoscopic management of arterial damage with endovascular closure devices used for a femoral arteriotomy. The ability to remotely suture a damaged artery permits the possible adaptation of this technology in managing endoscopic arterial complications. Technical note. After the creation of an endoscopic endonasal corridor in a cadaveric specimen, an arteriotomy was created at the cavernous portion of the internal carotid artery. The Angio-Seal, StarClose, and MynxGrip vascular closure devices were utilized under endoscopic guidance to repair the arteriotomy. Angiography was then done on a cadaver sutured with the StarClose. Both the Angio-Seal and StarClose were deployed quickly and appeared to provide sufficient closure of the arteriotomy. The Angio-Seal required the use of a guidewire and was longer to deploy when compared with the StarClose. The StarClose deployment was quick and facile. The MynxGrip also deployed without difficulty. The Angio-Seal and StarClose systems were both successfully deployed utilizing an endoscopic endonasal approach. The MynxGrip was the easiest to deploy and has the greatest potential to be of benefit in this application. Further studies with hemodynamic models are required to properly assess the appropriateness in this setting. NA. © 2014 The American Laryngological, Rhinological and Otological Society, Inc.

  2. [Current Status of Endoscopic Resection of Early Gastric Cancer in Korea].

    PubMed

    Jung, Hwoon Yong

    2017-09-25

    Endoscopic resection (Endoscopic mucosal resection [EMR] and endoscopic submucosal dissection [ESD]) is already established as a first-line treatment modality for selected early gastric cancer (EGC). In Korea, the number of endoscopic resection of EGC was explosively increased because of a National Cancer Screening Program and development of devices and techniques. There were many reports on the short-term and long-term outcomes after endoscopic resection in patients with EGC. Long-term outcome in terms of recurrence and death is excellent in both absolute and selected expanded criteria. Furthermore, endoscopic resection might be positioned as primary treatment modality replacing surgical gastrectomy. To obtain these results, selection of patients, perfect en bloc procedure, thorough pathological examination of resected specimen, accurate interpretation of whole process of endoscopic resection, and rational strategy for follow-up is necessary.

  3. The larynx ruler to measure height and profile of vocal folds: a proof of concept.

    PubMed

    Desuter, Gauthier; Mertens, Benjamin; Delchambre, Alain; van Lith-Bijl, Julie; van Benthem, Peter Paul; Sjögren, Elisabeth

    2017-01-01

    Glottic leakage during phonation is a direct consequence of unilateral vocal fold (VF) paralysis. This air leakage can be in the horizontal plane and in the vertical plane. Presently, there is no easily applicable medical device allowing noninvasive, office-based measurement of the relative vertical position of the VFs. The larynx ruler (LR) is a laser-based measuring device that could meet the previously stated need, using a flexible endoscope. This study represents a proof of concept regarding the use of the LR in assessing VF relative positions in the vertical plane. One fresh male human cadaver larynx, free of neurologic and anatomic disease, was explored with the LR system through the operative channel of a flexible gastroenterology video-endoscope. The tip of the video-endoscope was located in the laryngeal vestibule. The right crico-arytenoid joint was posteriorly disarticulated. Tilting of the VF was obtained by pulling or pushing the arytenoid cartilage with a mosquito forceps fixed to the stump of the previously sectioned superior tip of the posterior crico-arytenoid muscle allowing anterior and posterior tilting of the arytenoid cartilage in order to induce an elevation or a depression of the VF process. Ten "push" and ten "pull" sessions were performed. The distance from the tip of the video-endoscope to each illuminated pixel of the laser beam was recorded. The level difference between the left and right VFs was measured for each recording. Data provided by the LR were consistently in accordance with the movements applied on the VFs. The accuracy of 0.2 mm of the LR is compatible with the envisioned applications for the human larynx. The LR system represents a feasible technique to evaluate respective vertical position of VFs in the human larynx. Technical limitations were identified that will require improvements before experimental use on human beings.

  4. Biliary and pancreatic stenting: Devices and insertion techniques in therapeutic endoscopic retrograde cholangiopancreatography and endoscopic ultrasonography

    PubMed Central

    Mangiavillano, Benedetto; Pagano, Nico; Baron, Todd H; Arena, Monica; Iabichino, Giuseppe; Consolo, Pierluigi; Opocher, Enrico; Luigiano, Carmelo

    2016-01-01

    Stents are tubular devices made of plastic or metal. Endoscopic stenting is the most common treatment for obstruction of the common bile duct or of the main pancreatic duct, but also employed for the treatment of bilio-pancreatic leakages, for preventing post- endoscopic retrograde cholangiopancreatography pancreatitis and to drain the gallbladder and pancreatic fluid collections. Recent progresses in techniques of stent insertion and metal stent design are represented by new, fully-covered lumen apposing metal stents. These stents are specifically designed for transmural drainage, with a saddle-shape design and bilateral flanges, to provide lumen-to-lumen anchoring, reducing the risk of migration and leakage. This review is an update of the technique of stent insertion and metal stent deployment, of the most recent data available on stent types and characteristics and the new applications for biliopancreatic stents. PMID:26862364

  5. Experimental evaluation of an automated endoscope reprocessor with in situ generation of peracetic acid for disinfection of semicritical devices.

    PubMed

    Sattar, Syed A; Kibbee, Richard J; Tetro, Jason A; Rook, Tony A

    2006-11-01

    To evaluate the effectiveness of a high-level disinfection solution generated inside an endoscope processing system for decontaminating external and internal surfaces of experimentally contaminated heat-sensitive medical devices. The American Society for Testing and Materials Simulated-Use Test protocol (E1837-02), which incorporates a soil load in each inoculum, was used to evaluate the efficacy of the system when processing 4 common types of endoscopes contaminated separately with 5 types of nosocomial pathogens: Pseudomonas aeruginosa (ATCC 15442), spores of Clostridium difficile (ATCC 9689), a glutaraldehyde-resistant strain of Mycobacterium chelonae, a vancomycin-resistant strain of Enterococcus faecalis, and a methicillin-resistant strain of Staphylococcus aureus. Rinse solution samples from channels and from surfaces of the processed endoscopes were tested for any microbicidal residues. For all organisms tested, the baseline level of contamination of the endoscopes ranged from 5 log(10) to greater than 7 log(10) at each external surface site and internal channel. All tests showed reductions in viability of the test organisms to undetectable levels. All rinse solution samples from external and internal sites of the endoscopes proved to be free of any residual microbicidal activity. The endoscope reprocessor, with its processor-generated high-level disinfection solution, successfully reduced the numbers of selected, clinically relevant pathogens to undetectable levels both in the channels and on the outside surfaces of the 4 representative endoscopes tested in this study.

  6. An ingested mobile phone in the stomach may not be amenable to safe endoscopic removal using current therapeutic devices: A case report.

    PubMed

    Obinwa, Obinna; Cooper, David; O'Riordan, James M

    2016-01-01

    This case report is intended to inform clinicians, endoscopists, policy makers and industry of our experience in the management of a rare case of mobile phone ingestion. A 29-year-old prisoner presented to the Emergency Department with vomiting, ten hours after he claimed to have swallowed a mobile phone. Clinical examination was unremarkable. Both initial and repeat abdominal radiographs eight hours later confirmed that the foreign body remained in situ in the stomach and had not progressed along the gastrointestinal tract. Based on these findings, upper endoscopy was performed under general anaesthesia. The object could not be aligned correctly to accommodate endoscopic removal using current retrieval devices. Following unsuccessful endoscopy, an upper midline laparotomy was performed and the phone was delivered through an anterior gastrotomy, away from the pylorus. The patient made an uneventful recovery and underwent psychological counselling prior to discharge. In this case report, the use of endoscopy in the management when a conservative approach fails is questioned. Can the current endoscopic retrieval devices be improved to limit the need for surgical interventions in future cases? An ingested mobile phone in the stomach may not be amenable for removal using the current endoscopic retrieval devices. Improvements in overtubes or additional modifications of existing retrieval devices to ensure adequate alignment for removal without injuring the oesophagus are needed. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  7. A new rapid test for fecal calprotectin predicts endoscopic remission and postoperative recurrence in Crohn's disease.

    PubMed

    Lobatón, Triana; López-García, Alicia; Rodríguez-Moranta, Francisco; Ruiz, Alexandra; Rodríguez, Lorena; Guardiola, Jordi

    2013-12-01

    Fecal calprotectin (FC), as determined by the enzyme-linked immunoassay (ELISA) test, has been proposed as a promising biomarker of endoscopic activity in Crohn's disease (CD). However data on its accuracy in predicting endoscopic remission according to location and postoperative recurrence (POR) is scarce. Our objective was to evaluate the ability of FC determined by a new quantitative point-of-care test (FC-QPOCT) to predict endoscopic remission and POR in CD patients. FC was determined simultaneously by an enzyme-linked immunoassay test (FC-ELISA) and a FC-QPOCT in CD patients undergoing colonoscopy. Clinical disease activity was assessed according to the Crohn's Disease Activity Index (CDAI). Endoscopic results were assessed according to the Crohn's Disease Endoscopic Activity Index of Severity (CDEIS) and postoperative recurrence according to the Rutgeerts' score. A total of 115 ileocolonoscopies were performed (29 on patients with ileocolonic resection). FC levels correlated more closely with the CDEIS than leucocytes, platelets or CRP. The prediction of "endoscopic remission" (CDEIS<3), using FC-QPOCT (cut-off 272 μg/g) and FC-ELISA (cut-off 274 μg/g) presented an AUC of 0.933 and 0.935 respectively. FC-QPOCT results correlated better with endoscopic activity in the ileocolonic location (Pearson's correlation, r=0.879; P<0.001), than the colonic (r=0.725; P<0.001) or the ileal location (r=0.437; P=0.016). Median FC-QPOCT levels discriminated Rutgeerts' score i0-i1 from i2-i4 (98 (range 30-306) μg/g vs. 234.5 (range 100-612) μg/g respectively, P=0.012). FC determined by rapid quantitative test predicts "endoscopic remission" and endoscopic postoperative recurrence in CD patients. Copyright © 2013 European Crohn's and Colitis Organisation. Published by Elsevier B.V. All rights reserved.

  8. Smartphone adapters for flexible Nasolaryngoscopy: a systematic review.

    PubMed

    Quimby, A E; Kohlert, S; Caulley, L; Bromwich, M

    2018-05-08

    Flexible nasolaryngoscopy is an essential component of the otolaryngological physical exam. Historically, the ability to create and share video recordings of these endoscopic exams has been limited by poor mobility of fixed endoscopy towers. The advent of smartphone endoscope adapters has allowed physicians to create and share video recordings of endoscopy in a wide variety of locations that would not have previously been feasible. This paper sought to review the literature on the effect of smartphone endoscope adapters on patient care, patient satisfaction, and resident learning. This systematic review was conducted according to PRISMA guidelines. A systematic literature search was performed for all relevant English language studies (1946-2017) using Ovid MEDLINE, PubMed, and EMBASE. The study protocol was registered with the PROSPERO database. A total of 91 abstracts were identified and screened by two independent reviewers. Based on inclusion and exclusion criteria, three studies were selected and subjected to full-text extraction as well as quality assessment. These studies demonstrated high diagnostic accuracy and quality of smartphone adapter-recorded videos, and a benefit of these devices on resident education. Due to the heterogeneity of included studies' methods and measures, a meta-analysis was not possible, so a qualitative synthesis of the literature results was performed. Despite a paucity of data on the subject, the present study provided a comprehensive review of the literature, and suggested overall high diagnostic accuracy, quality, and enhancement of resident education with the use of smartphone endoscope adapters for flexible nasolaryngoscopy. CRD42018086714.

  9. Flexible Ultrathin Endoscope Integrated with Irrigation Suction Apparatus for Assisting Microneurosurgery.

    PubMed

    Otani, Naoki; Morimoto, Yuji; Fujii, Kazuya; Toyooka, Terushige; Wada, Kojiro; Mori, Kentaro

    2017-12-01

    Endoscopy can observe the anatomical components in a deeply located and/or hidden area during neurosurgical procedures under the operating microscope. We have newly developed a flexible ultrathin endoscope integrated with irrigation suction apparatus (FUEISA) to visualize deeply located and/or hidden areas for assisting microneurosurgery. The present study investigated the usefulness of the FUEISA system for direct clipping surgery of cerebral aneurysms. Twenty-one patients underwent microneurosurgery assisted with the FUEISA system for direct clipping of cerebral aneurysms. The flexible ultrathin endoscope (outer diameter 0.75mm) consists of an image guide (6000 dpi) and a light guide, integrated with the irrigation suction apparatus. This endoscopic system was inserted before and after clipping to observe the anatomical conditions surrounding the lesions. In all cases, handling and operation of the FUEISA was technically successful during the surgical procedure. The ultrathin endoscope was adequately integrated with the irrigation suction apparatus in all cases. General anatomy visualization including the lenticulostriate arteries, medial striate arteries, and/or internal carotid artery perforators was possible, and the correct clip positioning and vessel conditions were easily checked. The endoscope revealed that the clip had been positioned incorrectly in one case. No complications associated with the endoscopic system occurred. The FUEISA system can be applied with safe manipulation, which was remarkably useful for confirmation of the presence of perforators and cranial nerves behind the lesions, particularly anatomical components located in deep and/or hidden areas during clipping of cerebral aneurysms. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Applications of optical fibers and miniature photonic elements in medical diagnostics

    NASA Astrophysics Data System (ADS)

    Blaszczak, Urszula; Gilewski, Marian; Gryko, Lukasz; Zajac, Andrzej; Kukwa, Andrzej; Kukwa, Wojciech

    2014-05-01

    Construction of endoscopes which are known for decades, in particular in small devices with the diameter of few millimetres, are based on the application of fibre optic imaging bundles or bundles of fibers in the illumination systems (usually with a halogen source). Cameras - CCD and CMOS - with the sensor size of less than 5 mm emerging commercially and high power LED solutions allow to design and construct modern endoscopes characterized by many innovative properties. These constructions offer higher resolution. They are also relatively cheaper especially in the context of the integration of the majority of the functions on a single chip. Mentioned features of the CMOS sensors reduce the cycle of introducing the newly developed instruments to the market. The paper includes a description of the concept of the endoscope with a miniature camera built on the basis of CMOS detector manufactured by Omni Vision. The set of LEDs located at the operator side works as the illuminating system. Fibre optic system and the lens of the camera are used in shaping the beam illuminating the observed tissue. Furthermore, to broaden the range of applications of the endoscope, the illuminator allows to control the spectral characteristics of emitted light. The paper presents the analysis of the basic parameters of the light-and-optical system of the endoscope. The possibility of adjusting the magnifications of the lens, the field of view of the camera and its spatial resolution is discussed. Special attention was drawn to the issues related to the selection of the light sources used for the illumination in terms of energy efficiency and the possibility of providing adjusting the colour of the emitted light in order to improve the quality of the image obtained by the camera.

  11. A technical review of flexible endoscopic multitasking platforms.

    PubMed

    Yeung, Baldwin Po Man; Gourlay, Terence

    2012-01-01

    Further development of advanced therapeutic endoscopic techniques and natural orifice translumenal endoscopic surgery (NOTES) requires a powerful flexible endoscopic multitasking platform. Medline search was performed to identify literature relating to flexible endoscopic multitasking platform from year 2004-2011 using keywords: Flexible endoscopic multitasking platform, NOTES, Instrumentation, Endoscopic robotic surgery, and specific names of various endoscopic multitasking platforms. Key articles from articles references were reviewed. Flexible multitasking platforms can be classified as either mechanical or robotic. Purely mechanical systems include the dual channel endoscope (DCE) (Olympus), R-Scope (Olympus), the EndoSamurai (Olympus), the ANUBIScope (Karl-Storz), Incisionless Operating Platform (IOP) (USGI), and DDES system (Boston Scientific). Robotic systems include the MASTER system (Nanyang University, Singapore) and the Viacath (Hansen Medical). The DCE, the R-Scope, the EndoSamurai and the ANUBIScope have integrated visual function and instrument manipulation function. The IOP and DDES systems rely on the conventional flexible endoscope for visualization, and instrument manipulation is integrated through the use of a flexible, often lockable, multichannel access device. The advantage of the access device concept is that it allows optics and instrument dissociation. Due to the anatomical constrains of the pharynx, systems are designed to have a diameter of less than 20 mm. All systems are controlled by traction cable system actuated either by hand or by robotic machinery. In a flexible system, this method of actuation inevitably leads to significant hysteresis. This problem will be accentuated with a long endoscope such as that required in performing colonic procedures. Systems often require multiple operators. To date, the DCE, the R-Scope, the IOP, and the Viacath system have data published relating to their application in human. Alternative forms of instrument actuation, camera control and master console ergonomics should be explored to improve instrument precision, sphere of action, size and minimize assistance required. Copyright © 2012 Surgical Associates Ltd. Published by Elsevier Ltd. All rights reserved.

  12. [Endoscopic full-thickness resection].

    PubMed

    Meier, B; Schmidt, A; Caca, K

    2016-08-01

    Conventional endoscopic resection techniques such as endoscopic mucosal resection (EMR) or endoscopic submucosal dissection (ESD) are powerful tools for the treatment of gastrointestinal (GI) neoplasms. However, those techniques are limited to the superficial layers of the GI wall (mucosa and submucosa). Lesions without lifting sign (usually arising from deeper layers) or lesions in difficult anatomic positions (appendix, diverticulum) are difficult - if not impossible - to resect using conventional techniques, due to the increased risk of complications. For larger lesions (>2 cm), ESD appears to be superior to the conventional techniques because of the en bloc resection, but the procedure is technically challenging, time consuming, and associated with complications even in experienced hands. Since the development of the over-the-scope clips (OTSC), complications like bleeding or perforation can be endoscopically better managed. In recent years, different endoscopic full-thickness resection techniques came to the focus of interventional endoscopy. Since September 2014, the full-thickness resection device (FTRD) has the CE marking in Europe for full-thickness resection in the lower GI tract. Technically the device is based on the OTSC system and combines OTSC application and snare polypectomy in one step. This study shows all full-thickness resection techniques currently available, but clearly focuses on the experience with the FTRD in the lower GI tract.

  13. Endosonography guided management of pancreatic fluid collections

    PubMed Central

    Vilmann, Andreas S; Menachery, John; Tang, Shou-Jiang; Srinivasan, Indu; Vilmann, Peter

    2015-01-01

    The revised Atlanta classification of acute pancreatitis was adopted by international consensus, and is based on actual local and systemic determinants of disease severity. The local determinant is pancreatic necrosis (sterile or infected), and the systemic determinant is organ failure. Local complications of pancreatitis can include acute peri-pancreatic fluid collection, acute necrotic collection, pseudocyst formation, and walled-off necrosis. Interventional endoscopic ultrasound (EUS) has been increasing utilized in managing these local complications. After performing a PubMed search, the authors manually applied pre-defined inclusion criteria or a filter to identify publications relevant to EUS and pancreatic collections (PFCs). The authors then reviewed the utility, efficacy, and risks associated with using therapeutic EUS and involved EUS devices in treating PFCs. Due to the development and regulatory approval of improved and novel endoscopic devices specifically designed for transmural drainage of fluid and necrotic debris (access and patency devices), the authors predict continuing evolution in the management of PFCs. We believe that EUS will become an indispensable part of procedures used to diagnose PFCs and perform image-guided interventions. After draining a PFC, the amount of tissue necrosis is the most important predictor of a successful outcome. Hence, it seems logical to classify these collections based on their percentage of necrotic component or debris present when viewed by imaging methods or EUS. Finally, the authors propose an algorithm for managing fluid collections based on their size, location, associated symptoms, internal echogenic patterns, and content. PMID:26557008

  14. Design of wormlike automated robotic endoscope: dynamic interaction between endoscopic balloon and surrounding tissues.

    PubMed

    Poon, Carmen C Y; Leung, Billy; Chan, Cecilia K W; Lau, James Y W; Chiu, Philip W Y

    2016-02-01

    The current design of capsule endoscope is limited by the inability to control the motion within gastrointestinal tract. The rising incidence of gastrointestinal cancers urged improvement in the method of screening endoscopy. This preclinical study aimed to design and develop a novel locomotive module for capsule endoscope. We investigated the feasibility and physical properties of this newly designed caterpillar-like capsule endoscope with a view to enhancing screening endoscopy. This study consisted of preclinical design and experimental testing on the feasibility of automated locomotion for a prototype caterpillar endoscope. The movement was examined first in the PVC tube and then in porcine intestine. The image captured was transmitted to handheld device to confirm the control of movement. The balloon pressure and volume as well as the contact force between the balloon and surroundings were measured when the balloon was inflated inside (1) a hard PVC tube, (2) a soft PVC tube, (3) muscular sites of porcine colons and (4) less muscular sites of porcine colons. The prototype caterpillar endoscope was able to move inward and backward within the PVC tubing and porcine intestine. Images were able to be captured from the capsule endoscope attached and being observed with a handheld device. Using the onset of a contact force as indication of the buildup of the gripping force between the balloon and the lumen walls, it is concluded from the results of this study that the rate of change in balloon pressure and volume is two good estimators to optimize the inflation of the balloon. The results of this study will facilitate further refinement in the design of caterpillar robotic endoscope to move inside the GI tract.

  15. A Large Multicenter Experience With Endoscopic Suturing for Management of Gastrointestinal Defects and Stent Anchorage in 122 Patients: A Retrospective Review.

    PubMed

    Sharaiha, Reem Z; Kumta, Nikhil A; DeFilippis, Ersilia M; Dimaio, Christopher J; Gonzalez, Susana; Gonda, Tamas; Rogart, Jason; Siddiqui, Ali; Berg, Paul S; Samuels, Paul; Miller, Larry; Khashab, Mouen A; Saxena, Payal; Gaidhane, Monica R; Tyberg, Amy; Teixeira, Julio; Widmer, Jessica; Kedia, Prashant; Loren, David; Kahaleh, Michel; Sethi, Amrita

    2016-01-01

    To describe a multicenter experience using an endoscopic suturing device for management of gastrointestinal (GI) defects and stent anchorage. Endoscopic closure of GI defects including perforations, fistulas, and anastomotic leaks as well as stent anchorage has improved with technological advances. An endoscopic suturing device (OverStitch; Apollo Endosurgery Inc.) has been used. Retrospective study of consecutive patients who underwent endoscopic suturing for management of GI defects and/or stent anchorage were enrolled between March 2012 and January 2014 at multiple academic medical centers. Data regarding demographic information and outcomes including long-term success were collected. One hundred and twenty-two patients (mean age, 52.6 y; 64.2% females) underwent endoscopic suturing at 8 centers for stent anchorage (n=47; 38.5%), fistulas (n=40; 32.7%), leaks (n=15; 12.3%), and perforations (n=20; 16.4%). A total of 44.2% underwent prior therapy and 97.5% achieved technical success. Immediate clinical success was achieved in 79.5%. Long-term clinical success was noted in 78.8% with mean follow-up of 68 days. Clinical success was 91.4% in stent anchorage, 93% in perforations, 80% in fistulas, but only 27% in anastomotic leak closure. Endoscopic suturing for management of GI defects and stent anchoring is safe and efficacious. Stent migration after stent anchoring was reduced compared with published data. Long-term success without further intervention was achieved in the majority of patients. The role of endoscopic suturing for repair of anastomotic leaks remains unclear given limited success in this retrospective study.

  16. Supracerebellar Infratentorial Endoscopic and Endoscopic-Assisted Approaches to Pineal Lesions: Technical Report and Review of the Literature.

    PubMed

    Snyder, Rita; Felbaum, Daniel R; Jean, Walter C; Anaizi, Amjad

    2017-06-09

    The pineal gland has a deep central location, making it a surgeon's no man's land. Surgical pathology within this territory presents a unique challenge and an opportunity for employment of various surgical techniques. In modern times, the microsurgical technique has been competing with the endoscope for achieving superior surgical results. We describe two cases utilizing a purely endoscopic and an endoscopic-assisted supracerebellar infratentorial approach in accessing lesions of the pineal gland. We also discuss our early learning experience with these approaches.

  17. Supracerebellar Infratentorial Endoscopic and Endoscopic-Assisted Approaches to Pineal Lesions: Technical Report and Review of the Literature

    PubMed Central

    Felbaum, Daniel R; Jean, Walter C; Anaizi, Amjad

    2017-01-01

    The pineal gland has a deep central location, making it a surgeon’s no man’s land. Surgical pathology within this territory presents a unique challenge and an opportunity for employment of various surgical techniques. In modern times, the microsurgical technique has been competing with the endoscope for achieving superior surgical results. We describe two cases utilizing a purely endoscopic and an endoscopic-assisted supracerebellar infratentorial approach in accessing lesions of the pineal gland. We also discuss our early learning experience with these approaches. PMID:28690962

  18. Advanced endoscopic imaging to improve adenoma detection

    PubMed Central

    Neumann, Helmut; Nägel, Andreas; Buda, Andrea

    2015-01-01

    Advanced endoscopic imaging is revolutionizing our way on how to diagnose and treat colorectal lesions. Within recent years a variety of modern endoscopic imaging techniques was introduced to improve adenoma detection rates. Those include high-definition imaging, dye-less chromoendoscopy techniques and novel, highly flexible endoscopes, some of them equipped with balloons or multiple lenses in order to improve adenoma detection rates. In this review we will focus on the newest developments in the field of colonoscopic imaging to improve adenoma detection rates. Described techniques include high-definition imaging, optical chromoendoscopy techniques, virtual chromoendoscopy techniques, the Third Eye Retroscope and other retroviewing devices, the G-EYE endoscope and the Full Spectrum Endoscopy-system. PMID:25789092

  19. [The use of intraoperative Doppler ultrasound in endoscopic transsphenoidal surgery].

    PubMed

    Sharipov, O I; Kutin, M A; Kalinin, P L; Fomichev, D V; Lukshin, V A; Kurnosov, A B

    2016-01-01

    Doppler ultrasound (DUS) has been widely used in neurosurgical practice to diagnose various cerebrovascular diseases. This technique is used in transsphenoidal surgery to identify the localization of intracranial arteries when making an approach or during tumor resection. To identify the cavernous segment of the internal carotid artery (ICA) and/or basilar artery during endoscopic transsphenoidal surgery, we used a combined device on the basis of a click line curette («Karl Storz») and a 16 MHz Doppler probe (Lassamed). The technique was used in 51 patients during both standard transsphenoidal surgery (23 cases) and transsphenoidal tumor resection through an extended approach (28 cases). Doppler ultrasound was used in different situations: to determine a trajectory of the endonasal transsphenoidal approach in the absence of the normal anatomical landmarks (16 cases), to define the limits of safe resection of a tumor located in the laterosellar region (7), and to implement an extended transsphenoidal endoscopic approach (28). Intraoperative Doppler ultrasound enabled identification of the cavernous segment of the internal carotid artery in 45 cases and the basilar artery in 2 cases; a blood vessel was not found in 4 cases. Injury to the cavernous segment of the internal carotid artery was observed only in 1 case. The use of the described combined device in transsphenoidal surgery turned Doppler ultrasound into an important and useful technique for visualization of the ICA within the tumor stroma as well as in the case of the changed skull base anatomy. Its use facilitates manipulations in a deep and narrow wound and enables inspection of the entire surface of the operative field in various planes, thereby surgery becomes safer due to the possibility of maximum investigation of the operative field.

  20. Transmission of Infection by Flexible Gastrointestinal Endoscopy and Bronchoscopy

    PubMed Central

    Peters, Frans T. M.; van der Mei, Henny C.; Degener, John E.

    2013-01-01

    SUMMARY Flexible endoscopy is a widely used diagnostic and therapeutic procedure. Contaminated endoscopes are the medical devices frequently associated with outbreaks of health care-associated infections. Accurate reprocessing of flexible endoscopes involves cleaning and high-level disinfection followed by rinsing and drying before storage. Most contemporary flexible endoscopes cannot be heat sterilized and are designed with multiple channels, which are difficult to clean and disinfect. The ability of bacteria to form biofilms on the inner channel surfaces can contribute to failure of the decontamination process. Implementation of microbiological surveillance of endoscope reprocessing is appropriate to detect early colonization and biofilm formation in the endoscope and to prevent contamination and infection in patients after endoscopic procedures. This review presents an overview of the infections and cross-contaminations related to flexible gastrointestinal endoscopy and bronchoscopy and illustrates the impact of biofilm on endoscope reprocessing and postendoscopic infection. PMID:23554415

  1. Endoscopic ultrasound and endoscopic retrograde cholangiopancreatography: Can they be successfully combined?

    PubMed

    Gornals, Joan B; Esteban, José Miguel; Guarner-Argente, Carlos; Marra-Lopez, Carlos; Repiso, Alejandro; Sendino, Oriol; Loras, Carme

    2016-11-01

    Endoscopic ultrasound (EUS) and endoscopic retrograde cholangiopancreatography (ERCP) have much in common, including their main indications (biliopancreatic disorders), powerful therapeutic capacities and a steep learning curve. Over the years they have evolved from novel diagnostic procedures to interventional therapeutic techniques, but along different paths (different scopes or devices and endoscopists specializing exclusively in one or the other technique). However, EUS has gradually developed into a therapeutic technique that requires skills in the use of ERCP devices and stents, leading some ERCP specialists to explore the therapeutic potential of EUS. The corresponding literature, which has grown exponentially, includes recent experiments on combining the two techniques, which have gradually come to be used in routine care in a number of centers, with positive technical, clinical and financial outcomes. We review EUS and ERCP as individual or combined procedures for managing biliopancreatic disorders. Copyright © 2016 Elsevier España, S.L.U. y AEEH y AEG. All rights reserved.

  2. [Natural orifice trans-luminal endoscopic surgery (notes)--a new era in general surgery].

    PubMed

    Elazary, Ram; Horgan, Santiago; Talamini, Mark A; Rivkind, Avraham I; Mintz, Yoav

    2008-10-01

    Four years ago, a new surgical technique was presented, the natural orifice trans-luminal endoscopic surgery (NOTES). This technique provides an incisionless operation. The surgical devices are inserted into the peritoneal cavity through the gastrointestinal or the urogenital tracts. Today, a cholecystectomy can be performed using an advanced endoscope inserted through the stomach or the vagina. The advantages of NOTES are: reduced post operative pain, no hernias, no surgical wounds infections and better cosmetic results. The disadvantages are: difficulties in achieving safe enterotomy closure or a leak proof anastomosis, it necessitates performing more operations compared to open or laparoscopic operations in order to obtain the skills for performing these operations, and difficulties of acquiring satisfactory endoscopic vision due to lack of advanced technology. Several NOTES operations have already been performed in humans. However, many other surgical procedures were tested in laboratory animals. Development and improvement of surgical devices may promote this surgical modality in the future.

  3. Endoscopic therapy for early gastric cancer: Standard techniques and recent advances in ESD

    PubMed Central

    Kume, Keiichiro

    2014-01-01

    The technique of endoscopic submucosal dissection (ESD) is now a well-known endoscopic therapy for early gastric cancer. ESD was introduced to resect large specimens of early gastric cancer in a single piece. ESD can provide precision of histologic diagnosis and can also reduce the recurrence rate. However, the drawback of ESD is its technical difficulty, and, consequently, it is associated with a high rate of complications, the need for advanced endoscopic techniques, and a lengthy procedure time. Various advances in the devices and techniques used for ESD have contributed to overcoming these drawbacks. PMID:24914364

  4. Proof-of-concept of a laser mounted endoscope for touch-less navigated procedures

    PubMed Central

    Kral, Florian; Gueler, Oezguer; Perwoeg, Martina; Bardosi, Zoltan; Puschban, Elisabeth J; Riechelmann, Herbert; Freysinger, Wolfgang

    2013-01-01

    Background and Objectives During navigated procedures a tracked pointing device is used to define target structures in the patient to visualize its position in a registered radiologic data set. When working with endoscopes in minimal invasive procedures, the target region is often difficult to reach and changing instruments is disturbing in a challenging, crucial moment of the procedure. We developed a device for touch less navigation during navigated endoscopic procedures. Materials and Methods A laser beam is delivered to the tip of a tracked endoscope angled to its axis. Thereby the position of the laser spot in the video-endoscopic images changes according to the distance between the tip of the endoscope and the target structure. A mathematical function is defined by a calibration process and is used to calculate the distance between the tip of the endoscope and the target. The tracked tip of the endoscope and the calculated distance is used to visualize the laser spot in the registered radiologic data set. Results In comparison to the tracked instrument, the touch less target definition with the laser spot yielded in an over and above error of 0.12 mm. The overall application error in this experimental setup with a plastic head was 0.61 ± 0.97 mm (95% CI −1.3 to +2.5 mm). Conclusion Integrating a laser in an endoscope and then calculating the distance to a target structure by image processing of the video endoscopic images is accurate. This technology eliminates the need for tracked probes intraoperatively and therefore allows navigation to be integrated seamlessly in clinical routine. However, it is an additional chain link in the sequence of computer-assisted surgery thus influencing the application error. Lasers Surg. Med. 45:377–382, 2013. © 2013 Wiley Periodicals, Inc. PMID:23737122

  5. Endoscopes and robots for tight surgical spaces: use of precurved elastic elements to enhance curvature

    NASA Astrophysics Data System (ADS)

    Remirez, Andria A.; Webster, Robert J.

    2016-03-01

    Many applications in medicine require flexible surgical manipulators and endoscopes capable of reaching tight curvatures. The maximum curvature these devices can achieve is often restricted either by a strain limit, or by a maximum actuation force that the device's components can tolerate without risking mechanical failure. In this paper we propose the use of precurvature to "bias" the workspace of the device in one direction. Combined with axial shaft rotation, biasing increases the size of the device's workspace, enabling it to reach tighter curvatures than a comparable device without biasing can achieve, while still being able to fully straighten. To illustrate this effect, we describe several example prototype devices which use flexible nitinol strips that can be pushed and pulled to generate bending. We provide a statics model that relates the manipulator curvature to actuation force, and validate it experimentally.

  6. Efficiency optimization of wireless power transmission systems for active capsule endoscopes.

    PubMed

    Zhiwei, Jia; Guozheng, Yan; Jiangpingping; Zhiwu, Wang; Hua, Liu

    2011-10-01

    Multipurpose active capsule endoscopes have drawn considerable attention in recent years, but these devices continue to suffer from energy limitations. A wireless power supply system is regarded as a practical way to overcome the power shortage problem in such devices. This paper focuses on the efficiency optimization of a wireless energy supply system with size and safety constraints. A mathematical programming model in which these constraints are considered is proposed for transmission efficiency, optimal frequency and current, and overall system effectiveness. To verify the feasibility of the proposed method, we use a wireless active capsule endoscope as an illustrative example. The achieved efficiency can be regarded as an index for evaluating the system, and the proposed approach can be used to direct the design of transmitting and receiving coils.

  7. [Liver Abscess Secondary to Perforation after Duodenal Endoscopic Resection].

    PubMed

    Choi, Seung Ho; Kim, Su Jin; Kang, Dae Hwan; Kim, Hyung Wook; Choi, Cheol Woong; Kim, Tae Un; Lee, Jeong Seok; Ko, Ji Hwan

    2018-05-25

    Duodenal perforation is a complication of endoscopic mucosal resection. Liver abscess secondary to iatrogenic perforation is extremely rare. A 43-year-old female visited the hospital to remove a sub-epithelial tumor on the duodenal bulb. After endoscopic mucosal resection with band ligation, duodenal perforation occurred. Endoscopic closure was performed successfully using a clipping device to manage duodenal perforation. After 4 weeks, the patient visited our outpatient clinic due to abdominal pain and fever. Abdominal computed tomography showed liver abscess that involved segment three. Liver abscess was resolved with a 10-week antibiotic treatment. To the best of our knowledge, no case of liver abscess secondary to duodenal perforation by endoscopic resection was reported to date in Korea. Here, we report a case of liver abscess caused by a duodenal perforation after endoscopic mucosal resection.

  8. Study of urological devices coated with fullerene-like nanoparticles.

    PubMed

    Goldbart, Ohad; Elianov, Olga; Shumalinsky, Dmitry; Lobik, Leonid; Cytron, Shmuel; Rosentsveig, Rita; Wagner, H Daniel; Tenne, Reshef

    2013-09-21

    Insertion of endoscopes and other medical devices into the human body are ubiquitous, especially among aged males. The applied force for the insertion/extraction of the device from the urethra must overcome endoscope-surface-human-tissue interactions. In daily practice a gel is applied on the endoscope surface, in order to facilitate its entry into the urethra, providing also for local anesthesia. In the present work, a new solid-state lubricant has been added to the gel, in order to reduce the metal-urethra interaction and alleviate the potential damage to the epithelial tissue. For that purpose, a urethra model was designed and fabricated, which allowed a quantitative assessment of the applied force for extraction of the endoscope from a soft polymer-based ring. It is shown that the addition of MoS2 nanoparticles with fullerene-like structure (IF-MoS2) and in particular rhenium-doped nanoparticles (Re:IF-MoS2) to Esracain gel applied on the metal-lead reduced the friction substantially. The Re:IF-MoS2 showed better results than the undoped fullerene-like nanoparticles and both performed better than the gel alone. The mechanism of friction reduction is attributed to fullerenes' ability to roll and act as a separator between the active parts of the model.

  9. Study of urological devices coated with fullerene-like nanoparticles

    NASA Astrophysics Data System (ADS)

    Goldbart, Ohad; Elianov, Olga; Shumalinsky, Dmitry; Lobik, Leonid; Cytron, Shmuel; Rosentsveig, Rita; Wagner, H. Daniel; Tenne, Reshef

    2013-08-01

    Insertion of endoscopes and other medical devices into the human body are ubiquitous, especially among aged males. The applied force for the insertion/extraction of the device from the urethra must overcome endoscope-surface-human-tissue interactions. In daily practice a gel is applied on the endoscope surface, in order to facilitate its entry into the urethra, providing also for local anesthesia. In the present work, a new solid-state lubricant has been added to the gel, in order to reduce the metal-urethra interaction and alleviate the potential damage to the epithelial tissue. For that purpose, a urethra model was designed and fabricated, which allowed a quantitative assessment of the applied force for extraction of the endoscope from a soft polymer-based ring. It is shown that the addition of MoS2 nanoparticles with fullerene-like structure (IF-MoS2) and in particular rhenium-doped nanoparticles (Re:IF-MoS2) to Esracain gel applied on the metal-lead reduced the friction substantially. The Re:IF-MoS2 showed better results than the undoped fullerene-like nanoparticles and both performed better than the gel alone. The mechanism of friction reduction is attributed to fullerenes' ability to roll and act as a separator between the active parts of the model.

  10. Review of diagnostic and therapeutic endoscopic retrograde cholangiopancreatography using several endoscopic methods in patients with surgically altered gastrointestinal anatomy

    PubMed Central

    Shimatani, Masaaki; Takaoka, Makoto; Tokuhara, Mitsuo; Miyoshi, Hideaki; Ikeura, Tsukasa; Okazaki, Kazuichi

    2015-01-01

    The endoscopic approach for biliary diseases in patients with surgically altered gastrointestinal anatomy (SAGA) had been generally deemed impractical. However, it was radically made feasible by the introduction of double balloon endoscopy (DBE) that was originally developed for diagnosis and treatments for small-bowel diseases. Followed by the subsequent development of single-balloon endoscopy (SBE) and spiral endoscopy (SE), interventions using several endoscopes for biliary disease in patients with SAGA widely gained an acceptance as a new modality. Many studies have been made on this new technique. Yet, some problems are to be solved. For instance, the mutual unavailability among devices due to different working lengths and channels, and unestablished standardization of procedural techniques can be raised. Additionally, in an attempt to standardize endoscopic procedures, it is important to evaluate biliary cannulating methods by case with existence of papilla or not. A full comprehension of the features of respective scope types is also required. However there are not many papers written as a review. In our manuscript, we would like to evaluate and make a review of the present status of diagnostic and therapeutic endoscopic retrograde cholangiopancreatography applying DBE, SBE and SE for biliary diseases in patients with SAGA for establishment of these modalities as a new technology and further improvement of the scopes and devices. PMID:26078830

  11. Location, location, location: does early cancer in Barrett's esophagus have a preference?

    PubMed

    Enestvedt, Brintha K; Lugo, Ricardo; Guarner-Argente, Carlos; Shah, Pari; Falk, Gary W; Furth, Emma; Ginsberg, Gregory G

    2013-09-01

    Early cancer (high-grade dysplasia [HGD] and intramucosal carcinoma [ImCa]) associated with Barrett's esophagus (BE) may have a circumferential spatial predilection. To describe the esophageal circumferential location of early cancer in BE. Retrospective study, single tertiary referral center. One hundred nineteen patients were referred for endoscopic eradication therapy for early cancer associated with BE. Endoscopic images and reports and pathology were reviewed. Circumferential location designation of early cancer in BE by using a clock-face orientation. One hundred nineteen of 131 patients referred for endoscopic eradication therapy had a location designation for their advanced histology (91.9%). There were a total of 57 patients (47.9%) with HGD and 62 patients (52.1%) with ImCa. There was a significantly higher rate of early cancer (HGD or ImCa) in the right hemisphere (12 to 6 o'clock location) compared with the left hemisphere (84.9% vs 15.1%, P < .0001). The highest percentage of early cancer was found in the 12 to 3 o'clock quadrant (64.7%); 71.9% of HGD and 58.1% of ImCa lesions were located in the 12 to 3 o'clock quadrant. Retrospective design, single center. Early cancer associated with BE is far more commonly found in the right hemisphere of the esophagus (12 to 6 o'clock) with the highest rate in the 12 to 3 o'clock quadrant. These findings support enhanced scrutiny of the right hemisphere of the esophagus during surveillance and endoscopic treatment of patients with BE. Copyright © 2013 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  12. Endoscopic neurosurgery "around the corner" with a rigid endoscope. Technical note.

    PubMed

    Hopf, N J

    1999-03-01

    Endoscopically "working around the corner" is presently restricted to the use of flexible endoscopes or an endoscope-assisted microneurosurgical (EAM) technique. In order to overcome the limitations of these solutions, endoscopic equipment and techniques were developed for "working around the corner" with rigid endoscopes. A steering insert with a 5 French working channel is capable of steering instruments around the corner by actively bending the guiding track and consecutively the instrument. A special fixation device enables strict axial rotation of the endoscope in the operating field. Endoscopic procedures "around the corner", including aqueductal stenting, pellucidotomy, third ventriculostomy and biopsy were performed in human cadavers. Special features of the used pediatric neuroendoscope system, i.e., reliable fixation, axial rotation, and controlled steering of instruments, increase the safety and reduce the surgical traumatization in selected cases, such as obstructive hydrocephalus due to a mass lesion in the posterior third ventricle, since endoscopic third ventriculostomy and biopsy can be performed through the same burr hole trephination. Limitations of this technique are given by the size of the foramen of Monro and the height of the third ventricle as well as by the bending angle of the instruments (40-50 degrees).

  13. Clinical outcomes of endoscopic submucosa dissection for high-grade dysplasia from endoscopic forceps biopsy.

    PubMed

    Ryu, Dae Gon; Choi, Cheol Woong; Kang, Dae Hwan; Kim, Hyung Wook; Park, Su Bum; Kim, Su Jin; Nam, Hyeong Seok

    2017-07-01

    Although the Vienna Classification recommends endoscopic resection for gastric high-grade dysplasia (HGD), many resected lesions are diagnosed as gastric cancer after endoscopic resection. This study aims to evaluate the clinical outcomes of gastric HGD identified by endoscopic forceps biopsy (EFB) after endoscopic submucosal dissection (ESD) and factors associated with discrepant results. From December 2008 to July 2015, a total of 427 lesions diagnosed as initial HGD by EFB were enrolled. The rate of early gastric cancer (EGC) and factors predicting diagnosis upgrade were analyzed retrospectively. Tumors ranged between 2 and 65 mm in size (median 12.59). En bloc and complete resection rates were 97.4 and 95.3%, respectively. The diagnostic discrepancy rate was 76.3%. Upgrade and downgrade rates of pathological diagnoses were 66.5 and 9.8%, respectively. Central depression (OR 4.151), nodular surface (OR 5.582), surface redness (OR 2.926), lesion location (upper third of the stomach) (OR 3.894), and tumor size ≥10 mm (OR 2.287) were significantly associated with EGC. Nodular surface (OR 2.746), submucosal fibrosis (OR 3.958), lesion location (upper third of the stomach) (OR 6.652), and tumor size ≥10 mm (OR 4.935) significantly predicted invasive submucosal cancer. Central depression, nodular surface, surface redness, lesion location, large tumor size, and submucosal fibrosis were associated with EGC or submucosal cancer. Caution must be used in treating lesions with these features with ESD.

  14. Endoscopic management of hilar biliary strictures

    PubMed Central

    Singh, Rajiv Ranjan; Singh, Virendra

    2015-01-01

    Hilar biliary strictures are caused by various benign and malignant conditions. It is difficult to differentiate benign and malignant strictures. Postcholecystectomy benign biliary strictures are frequently encountered. Endoscopic management of these strictures is challenging. An endoscopic method has been advocated that involves placement of increasing number of stents at regular intervals to resolve the stricture. Malignant hilar strictures are mostly unresectable at the time of diagnosis and only palliation is possible.Endoscopic palliation is preferred over surgery or radiological intervention. Magnetic resonance cholangiopancreaticography is quite important in the management of these strictures. Metal stents are superior to plastic stents. The opinion is divided over the issue of unilateral or bilateral stenting.Minimal contrast or no contrast technique has been advocated during endoscopic retrograde cholangiopancreatography of these patients. The role of intraluminal brachytherapy, intraductal ablation devices, photodynamic therapy, and endoscopic ultrasound still remains to be defined. PMID:26191345

  15. Flexible endoscopes: structure and function. The suction and biopsy channel.

    PubMed

    Holland, P

    2001-01-01

    Flexible endoscopes are complex medical instruments that are easily damaged. To maintain the flexible endoscope in optimum working condition, the user must have a thorough understanding of the structure and function of the instrument. This is the second in a series of articles presenting an in-depth look at the care and handling of the flexible endoscope. The first article discussed the air and water system. This article will focus specifically on the suction and biopsy channel system. The flexible endoscope is constructed of several systems that operate simultaneously to produce a highly technical, yet effective diagnostic and therapeutic medical device. These systems include the air and water system, the suction or operating channel system, the mechanical system, the endoscopic retrograde cholangiopancreatography (ERCP) elevator system, the optical system, and the electrical system. A review of the internal and external structure of the flexible endoscope and the functions of the channel system, including infection control issues, potential problems and evaluation, and prevention of minor problems to avoid expensive repairs, will be addressed.

  16. Frontal burr hole approach for neuroendoscopic resection of craniopharyngioma with the NICO Myriad device: report of two cases.

    PubMed

    Moore, Reilin J; Scherer, Andrea; Fulkerson, Daniel H

    2017-04-01

    Craniopharyngiomas are challenging tumors to resect due to their deep location and proximity to vital structures. The perceived benefit of gross total resection may be tempered by the possibility of permanent disability. Minimally invasive techniques may reduce surgical morbidity while still allowing effective resection. The authors describe their initial experience with a neuroendoscopic transcortical, transventricular approach to two craniopharyngiomas. The surgeries were performed through a right frontal burr hole using the NICO Myriad, a side-cutting, aspiration device that fits through the working channel of a standard neuroendoscope. The imaging and medical records of two children (a 5-year-old male and a 9-year-old female) undergoing endoscopic resection of a craniopharyngioma with this technique were reviewed. Outcomes, results, and complications were noted. A gross total resection was achieved in both patients. The operative time was 180 and 143 min, respectively. The estimated blood loss was 20 and 50 cm 3 , respectively. Both patients required a cerebrospinal fluid shunt. There were no surgical complications. The NICO Myriad is an effective tool that allows a safe minimally invasive endoscopic resection of craniopharyngiomas in patients with amenable anatomy. Surgeons with experience in neuroendoscopy may be able to achieve a gross total resection of these challenging tumors through a minimally invasive burr hole approach.

  17. Enhanced differential evolution to combine optical mouse sensor with image structural patches for robust endoscopic navigation.

    PubMed

    Luo, Xiongbiao; Jayarathne, Uditha L; McLeod, A Jonathan; Mori, Kensaku

    2014-01-01

    Endoscopic navigation generally integrates different modalities of sensory information in order to continuously locate an endoscope relative to suspicious tissues in the body during interventions. Current electromagnetic tracking techniques for endoscopic navigation have limited accuracy due to tissue deformation and magnetic field distortion. To avoid these limitations and improve the endoscopic localization accuracy, this paper proposes a new endoscopic navigation framework that uses an optical mouse sensor to measure the endoscope movements along its viewing direction. We then enhance the differential evolution algorithm by modifying its mutation operation. Based on the enhanced differential evolution method, these movement measurements and image structural patches in endoscopic videos are fused to accurately determine the endoscope position. An evaluation on a dynamic phantom demonstrated that our method provides a more accurate navigation framework. Compared to state-of-the-art methods, it improved the navigation accuracy from 2.4 to 1.6 mm and reduced the processing time from 2.8 to 0.9 seconds.

  18. Evaluation of a novel flexible snake robot for endoluminal surgery.

    PubMed

    Patel, Nisha; Seneci, Carlo A; Shang, Jianzhong; Leibrandt, Konrad; Yang, Guang-Zhong; Darzi, Ara; Teare, Julian

    2015-11-01

    Endoluminal therapeutic procedures such as endoscopic submucosal dissection are increasingly attractive given the shift in surgical paradigm towards minimally invasive surgery. This novel three-channel articulated robot was developed to overcome the limitations of the flexible endoscope which poses a number of challenges to endoluminal surgery. The device enables enhanced movement in a restricted workspace, with improved range of motion and with the accuracy required for endoluminal surgery. To evaluate a novel flexible robot for therapeutic endoluminal surgery. Bench-top studies. Research laboratory. Targeting and navigation tasks of the robot were performed to explore the range of motion and retroflexion capabilities. Complex endoluminal tasks such as endoscopic mucosal resection were also simulated. Successful completion, accuracy and time to perform the bench-top tasks were the main outcome measures. The robot ranges of movement, retroflexion and navigation capabilities were demonstrated. The device showed significantly greater accuracy of targeting in a retroflexed position compared to a conventional endoscope. Bench-top study and small study sample. We were able to demonstrate a number of simulated endoscopy tasks such as navigation, targeting, snaring and retroflexion. The improved accuracy of targeting whilst in a difficult configuration is extremely promising and may facilitate endoluminal surgery which has been notoriously challenging with a conventional endoscope.

  19. 21 CFR 884.4150 - Bipolar endoscopic coagulator-cutter and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Bipolar endoscopic coagulator-cutter and accessories. 884.4150 Section 884.4150 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND... watts, and (D) For devices with ammeters: continue electrode activation for 5 seconds after the visual...

  20. Minimally invasive removal of a recurrent lumbar herniated nucleus pulposus by the small incised microendoscopic discectomy interlaminar approach.

    PubMed

    Koga, S; Sairyo, K; Shibuya, I; Kanamori, Y; Kosugi, T; Matsumoto, H; Kitagawa, Y; Sumita, T; Dezawa, A

    2012-02-01

    In this report, we introduce two cases of recurrent herniated nucleus pulposus (HNP) at L5-S1 that were successfully removed using the small incised microendoscopic discectomy (sMED) technique, proposed by Dezawa and Sairyo in 2011. sMED was performed via the interlaminar approach with a percutaneous endoscope. The patients had previously underdone microendoscopic discectomy for HNP. For the recurrent HNP, the sMED interlaminar approach was selected because the HNP occurred at the level of L5-S1; the percutaneous endoscopic transforaminal approach was not possible for anatomical reasons. To perform sMED via the interlaminar approach, we employed new, specially made devices to enable us to use this technique. In conclusion, sMED is the most minimally invasive approach available for HNP, and its limitations have been gradually eliminated with the introduction specially made devices. In the near future, percutaneous endoscopic surgery could be the gold standard for minimally invasive disc surgery. © 2012 Japan Society for Endoscopic Surgery, Asia Endosurgery Task Force and Blackwell Publishing Asia Pty Ltd.

  1. Optical design of a dual wave band catadioptric endoscope for the Joint European Torus

    NASA Astrophysics Data System (ADS)

    Greco, Vincenzo; Maddaluno, Giorgio

    2004-02-01

    In this paper we describe the optical design of a catadioptric endoscope for the Joint European Torus (JET). The JET is the flagship experiment in the European nuclear fusion research programme. It is a large tokamak (Russian acronym for "toroidal magnetic chamber") system located at Culham (UK). At the centre of this machine there is a toroidal (ring - shaped) vacuum vessel where the plasma is confined by magnetic fields. The endoscope explores in two wave bands (4.2 μm - 4.4 μm and 0.6 μm - 0.7 μm) an entire cross section of the vacuum vessel. It then creates for each wave band an image onto a separate area image sensor, located 5500 mm away from the plasma behind a concrete shield. The endoscope performs two different functions namely: infrared thermography on plasma facing components and in vessel inspection.

  2. 5-ALA/PpIX fluorescence detection of gastrointestinal neoplasia

    NASA Astrophysics Data System (ADS)

    Borisova, Ekaterina G.; Vladimirov, Borislav; Terziev, Ivan; Ivanova, Radina; Avramov, Latchezar

    2009-07-01

    In the recent study delta-ALA/PpIX is used as fluorescent marker for dysplasia and tumor detection in esophagus, stomach and colon. ALA is administered per os six to eight (depending on the lesion location) hours before measurements at dose 20mg/kg weight. High-power light-emitting diode at 405 nm is used as an excitation source. Special opto-mechanical device is built for the LED to use the light guide of standard video-endoscopic system. Through endoscopic instrumental channel a fiber is applied to return information about fluorescence to microspectrometer. The fluorescence detected from tumor sites has very complex spectral origins. It consists of autofluorescence, fluorescence from exogenous fluorophores and re-absorption from the chromophores accumulated in the tissue investigated. Spectral features observed during endoscopic investigations could be distinct as the next regions: 450-630 nm region, where tissue autofluorescence is observed; 630-710 nm region, where fluorescence of PpIX is clearly pronounced; 530-580 nm region, where minima in the autofluorescence signal are observed, related to re-absorption of oxy-hemoglobin in this spectral area. Endogenous and exogenous fluorescence spectra are used to develop simple but effective algorithm, based on dimensionless ratio of the signals at 560 and 635 nm, for differentiation of normal/abnormal gastrointestinal tissues. Very good correlation between fluorescence signals and histology examination of the lesions investigated is achieved.

  3. Duodenal endoscopic full-thickness resection (with video).

    PubMed

    Schmidt, Arthur; Meier, Benjamin; Cahyadi, Oscar; Caca, Karel

    2015-10-01

    Endoscopic resection of duodenal non-lifting adenomas and subepithelial tumors is challenging and harbors a significant risk of adverse events. We report on a novel technique for duodenal endoscopic full-thickness resection (EFTR) by using an over-the-scope device. Data of 4 consecutive patients who underwent duodenal EFTR were analyzed retrospectively. Main outcome measures were technical success, R0 resection, histologic confirmation of full-thickness resection, and adverse events. Resections were done with a novel, over-the-scope device (full-thickness resection device, FTRD). Four patients (median age 60 years) with non-lifting adenomas (2 patients) or subepithelial tumors (2 patients) underwent EFTR in the duodenum. All lesions could be resected successfully. Mean procedure time was 67.5 minutes (range 50-85 minutes). Minor bleeding was observed in 2 cases; blood transfusions were not required. There was no immediate or delayed perforation. Mean diameter of the resection specimen was 28.3 mm (range 22-40 mm). Histology confirmed complete (R0) full-thickness resection in 3 of 4 cases. To date, 2-month endoscopic follow-up has been obtained in 3 patients. In all cases, the over-the-scope clip was still in place and could be removed without adverse events; recurrences were not observed. EFTR in the duodenum with the FTRD is a promising technique that has the potential to spare surgical resections. Modifications of the device should be made to facilitate introduction by mouth. Prospective studies are needed to further evaluate efficacy and safety for duodenal resections. Copyright © 2015 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  4. Towards non-contact photo-acoustic endoscopy using speckle pattern analysis

    NASA Astrophysics Data System (ADS)

    Lengenfelder, Benjamin; Mehari, Fanuel; Tang, Yuqi; Klämpfl, Florian; Zalevsky, Zeev; Schmidt, Michael

    2017-03-01

    Photoacoustic Tomography combines the advantages of optical and acoustic imaging as it makes use of the high optical contrast of tissue and the high resolution of ultrasound. Furthermore, high penetration depths in tissue in the order of several centimeters can be achieved by the combination of these modalities. Extensive research is being done in the field of miniaturization of photoacoustic devices, as photoacoustic imaging could be of significant benefits for the physician during endoscopic interventions. All the existing miniature systems are based on contact transducers for signal detection that are placed at the distal end of an endoscopic device. This makes the manufacturing process difficult and impedance matching to the inspected surface a requirement. The requirement for contact limits the view of the physician during the intervention. Consequently, a fiber based non-contact optical sensing technique would be highly beneficial for the development of miniaturized photoacoustic endoscopic devices. This work demonstrates the feasibility of surface displacement detection using remote speckle-sensing using a high speed camera and an imaging fiber bundle that is used in commercially available video endoscopes. The feasibility of displacement sensing is demonstrated by analysis of phantom vibrations which are induced by loudspeaker membrane oscillations. Since the usability of the remote speckle-sensing for photo-acoustic signal detection was already demonstrated, the fiber bundle approach demonstrates the potential for non-contact photoacoustic detections during endoscopy.

  5. Wireless Power Transfer to Millimeter-Sized Gastrointestinal Electronics Validated in a Swine Model.

    PubMed

    Abid, Abubakar; O'Brien, Jonathan M; Bensel, Taylor; Cleveland, Cody; Booth, Lucas; Smith, Brian R; Langer, Robert; Traverso, Giovanni

    2017-04-27

    Electronic devices placed in the gastrointestinal (GI) tract for prolonged periods have the potential to transform clinical evaluation and treatment. One challenge to the deployment of such gastroresident electronics is the difficulty in powering millimeter-sized electronics devices without using batteries, which compromise biocompatibility and long-term residence. We examined the feasibility of leveraging mid-field wireless powering to transfer power from outside of the body to electronics at various locations along the GI tract. Using simulations and ex vivo measurements, we designed mid-field antennas capable of operating efficiently in tissue at 1.2 GHz. These antennas were then characterized in vivo in five anesthetized pigs, by placing one antenna outside the body, and the other antenna inside the body endoscopically, at the esophagus, stomach, and colon. Across the animals tested, mean transmission efficiencies of -41.2, -36.1, and -34.6 dB were achieved in vivo while coupling power from outside the body to the esophagus, stomach, and colon, respectively. This corresponds to power levels of 37.5 μW, 123 μW and 173 μW received by antennas in the respective locations, while keeping radiation exposure levels below safety thresholds. These power levels are sufficient to wirelessly power a range of medical devices from outside of the body.

  6. Wireless Power Transfer to Millimeter-Sized Gastrointestinal Electronics Validated in a Swine Model

    NASA Astrophysics Data System (ADS)

    Abid, Abubakar; O'Brien, Jonathan M.; Bensel, Taylor; Cleveland, Cody; Booth, Lucas; Smith, Brian R.; Langer, Robert; Traverso, Giovanni

    2017-04-01

    Electronic devices placed in the gastrointestinal (GI) tract for prolonged periods have the potential to transform clinical evaluation and treatment. One challenge to the deployment of such gastroresident electronics is the difficulty in powering millimeter-sized electronics devices without using batteries, which compromise biocompatibility and long-term residence. We examined the feasibility of leveraging mid-field wireless powering to transfer power from outside of the body to electronics at various locations along the GI tract. Using simulations and ex vivo measurements, we designed mid-field antennas capable of operating efficiently in tissue at 1.2 GHz. These antennas were then characterized in vivo in five anesthetized pigs, by placing one antenna outside the body, and the other antenna inside the body endoscopically, at the esophagus, stomach, and colon. Across the animals tested, mean transmission efficiencies of -41.2, -36.1, and -34.6 dB were achieved in vivo while coupling power from outside the body to the esophagus, stomach, and colon, respectively. This corresponds to power levels of 37.5 μW, 123 μW and 173 μW received by antennas in the respective locations, while keeping radiation exposure levels below safety thresholds. These power levels are sufficient to wirelessly power a range of medical devices from outside of the body.

  7. Clinical relevance of aberrant polypoid nodule scar after endoscopic submucosal dissection

    PubMed Central

    Arantes, Vitor; Uedo, Noriya; Pedrosa, Moises Salgado; Tomita, Yasuhiko

    2016-01-01

    AIM To describe a series of patients with aberrant polypoid nodule scar developed after gastric endoscopic submucosal dissection (ESD), and to discuss its pathogenesis and clinical management. METHODS We reviewed retrospectively the endoscopic database of two academic institutions located in Brazil and Japan and searched for all patients that underwent ESD to manage gastric neoplasms from 2003 to 2015. The criteria for admission in the study were: (1) successful en bloc ESD procedure with R0 and curative resection confirmed histologically; (2) postoperative endoscopic examination with identification of a polypoid nodule scar (PNS) at ESD scar; (3) biopsies of the PNS with hyperplastic or regenerative tissue, reviewed by two independent experienced gastrointestinal pathologists, one from each Institution. Data were examined for patient demographics, Helicobacter pylori status, precise neoplastic lesion location in the stomach, tumor size, histopathological assessment of the ESD specimen, and postoperative information including medical management, endoscopic and histological findings, and clinical outcome. RESULTS A total of 14 patients (10 men/4 women) fulfilled the inclusion criteria and were enrolled in this study. One center contributed with 8 cases out of 60 patients (13.3%) from 2008 to 2015. The second center contributed with 6 cases (1.7%) out of 343 patients from 2003 to 2015. Postoperative endoscopic follow-up revealed similar findings in all patients: A protruded polypoid appearing nodule situated in the center of the ESD scar surrounded by convergence of folds. Biopsies samples were taken from PNS, and histological assessment revealed in all cases regenerative and hyperplastic tissue, without recurrent tumor or dysplasia. Primary neoplastic lesions were located in the antrum in 13 patients and in the angle in one patient. PNS did not develop in any patient after ESD undertaken for tumors located in the corpus, fundus or cardia. All patients have been followed systematically on an annual basis and no malignant recurrence in the ESD scar has been identified (mean follow-up period: 45 mo). CONCLUSION PNS may occur after ESD for antral lesions and endoscopically look concerning, especially for the patient or the family doctor. However, as long as curative R0 resection was successfully achieved and histology demonstrates only regenerative and hyperplastic tissue, PNS should be viewed as a benign alteration that does not require any type of intervention, other than endoscopic surveillance. PMID:27668074

  8. Evaluation of Ignition and Burn Risk Associated with Contemporary Fiberoptic and Distal Sensor Endoscopic Technology.

    PubMed

    Spradling, Kyle; Uribe, Brittany; Okhunov, Zhamshid; Hofmann, Martin; Del Junco, Michael; Hwang, Christina; Gruber, Caden; Youssef, Ramy F; Landman, Jaime

    2015-09-01

    To evaluate the ignition and burn risk associated with contemporary fiberoptic and distal sensor endoscopic technologies. We used new and used SCB Xenon 300 light sources to illuminate a 4.8 mm fiberoptic cable, 10 mm laparoscope, 5 mm laparoscope, rigid cystoscope, semirigid ureteroscope, flexible cystoscope, flexible fiberoptic ureteroscope, distal sensor cystoscope, and a distal sensor ureteroscope (Karl Storz, Inc., Tuttlingen, Germany). We measured peak temperatures at the distal end of each device. We then evaluated each device on a flat and folded surgical drape to establish ignition risk. Finally, we evaluated the effects of all devices on human cadaver skin covered by surgical drape. Peak temperatures recorded for each device ranged from 26.9°C (flexible fiberoptic ureteroscope) to 194.5°C (fiberoptic cable). Drape ignition was noted when the fiberoptic cable was placed against a fold of drape. Contact with the fiberoptic cable, 10 mm laparoscope, 5 mm laparoscope, and distal sensor cystoscope resulted in cadaver skin damage. Cadaver skin damage occurred despite little or no visible change to the surgical drape. Rigid and flexible fiberoptic cystoscopes and flexible fiberoptic ureteroscopes had no effect on surgical drapes or cadaver skin. Fiberoptic light cables and some endoscopic devices have the potential to cause thermal injury and drape ignition. Thermal injury may occur without visible damage to drapes. Surgeons should remain vigilant regarding the risks associated with these devices and take necessary safety precautions to prevent patient injury.

  9. Robotics and systems technology for advanced endoscopic procedures: experiences in general surgery.

    PubMed

    Schurr, M O; Arezzo, A; Buess, G F

    1999-11-01

    The advent of endoscopic techniques changed surgery in many regards. This paper intends to describe an overview about technologies to facilitate endoscopic surgery. The systems described have been developed for the use in general surgery, but an easy application also in the field of cardiac surgery seems realistic. The introduction of system technology and robotic technology enables today to design a highly ergonomic solo-surgery platform. To relief the surgeon from fatigue we developed a new chair dedicated to the functional needs of endoscopic surgery. The foot pedals for high frequency, suction and irrigation are integrated into the basis of the chair. The chair is driven by electric motors controlled with an additional foot pedal joystick to achieve the desired position in the OR. A major enhancement for endoscopic technology is the introduction of robotic technology to design assisting devices for solo-surgery and manipulators for microsurgical instrumentation. A further step in the employment of robotic technology is the design of 'master-slave manipulators' to provide the surgeon with additional degrees of freedom of instrumentation. In 1996 a first prototype of an endoscopic manipulator system. named ARTEMIS, could be used in experimental applications. The system consists of a user station (master) and an instrument station (slave). The surgeon sits at a console which integrates endoscopic monitors, communication facilities and two master devices to control the two slave arms which are mounted to the operating table. Clinical use of the system, however, will require further development in the area of slave mechanics and the control system. Finally the implementation of telecommunication technology in combination with robotic instruments will open new frontiers, such as teleconsulting, teleassistance and telemanipulation.

  10. Endoscopic graduated multiangle, multicorridor resection of juvenile nasopharyngeal angiofibroma: an individualized, tailored, multicorridor skull base approach.

    PubMed

    Liu, James K; Husain, Qasim; Kanumuri, Vivek; Khan, Mohemmed N; Mendelson, Zachary S; Eloy, Jean Anderson

    2016-05-01

    OBJECT Juvenile nasopharyngeal angiofibromas (JNAs) are formidable tumors because of their hypervascularity and difficult location in the skull base. Traditional transfacial procedures do not always afford optimal visualization and illumination, resulting in significant morbidity and poor cosmesis. The advent of endoscopic procedures has allowed for resection of JNAs with greater surgical freedom and decreased incidence of facial deformity and scarring. METHODS This report describes a graduated multiangle, multicorridor, endoscopic approach to JNAs that is illustrated in 4 patients, each with a different tumor location and extent. Four different surgical corridors in varying combinations were used to resect JNAs, based on tumor size and location, including an ipsilateral endonasal approach (uninostril); a contralateral, transseptal approach (binostril); a sublabial, transmaxillary Caldwell-Luc approach; and an orbitozygomatic, extradural, transcavernous, infratemporal fossa approach (transcranial). One patient underwent resection via an ipsilateral endonasal uninostril approach (Corridor 1) only. One patient underwent a binostril approach that included an additional contralateral transseptal approach (Corridors 1 and 2). One patient underwent a binostril approach with an additional sublabial Caldwell-Luc approach for lateral extension in the infratemporal fossa (Corridors 1-3). One patient underwent a combined transcranial and endoscopic endonasal/sublabial Caldwell-Luc approach (Corridors 1-4) for an extensive JNA involving both the lateral infratemporal fossa and cavernous sinus. RESULTS A graduated multiangle, multicorridor approach was used in a stepwise fashion to allow for maximal surgical exposure and maneuverability for resection of JNAs. Gross-total resection was achieved in all 4 patients. One patient had a postoperative CSF leak that was successfully repaired endoscopically. One patient had a delayed local recurrence that was successfully resected endoscopically. There were no vascular complications. CONCLUSIONS An individualized, multiangle, multicorridor approach allows for safe and effective surgical customization of access for resection of JNAs depending on the size and exact location of the tumor. Combining the endoscopic endonasal approach with a transcranial approach via an orbitozygomatic, extradural, transcavernous approach may be considered in giant extensive JNAs that have intracranial extension and intimate involvement of the cavernous sinus.

  11. Predictive factors for outcomes of patients undergoing endoscopic therapy for bile leak after hepatobiliary surgery.

    PubMed

    Yabe, Shuntaro; Kato, Hironari; Mizukawa, Sho; Akimoto, Yutaka; Uchida, Daisuke; Seki, Hiroyuki; Tomoda, Takeshi; Matsumoto, Kazuyuki; Yamamoto, Naoki; Horiguchi, Shigeru; Tsutsumi, Koichiro; Okada, Hiroyuki

    2017-05-01

    Endoscopic procedures are used as first-line treatment for bile leak after hepatobiliary surgery. Advances have been made in endoscopic techniques and devices, but few reports have described the effectiveness of endoscopic procedures and the management principles based on severity of bile leak. We evaluated the effectiveness of an endoscopic procedure for the treatment of bile leak after hepatobiliary surgery. Fifty-eight patients underwent an endoscopic procedure for suspected bile leak after hepatobiliary surgery; the presence of bile leak on endoscopic retrograde cholangiopancreatography (ERCP) was evaluated retrospectively. Two groups were created based on bile leak severity at ERCP. We defined success as follows: technical, successful placement of the plastic stent at the intended bile duct; clinical, improvement in symptoms of bile leak; and eventual, disappearance of bile leak at ERCP. We evaluated several factors that influenced the success of the endoscopic procedure and the differences between bile leak severity. Success rates were as follows: technical, 90%; clinical, 79%; and eventual, 71%. Median interval between first endoscopic procedure and achievement of eventual success was 135 days (IQR, 86-257 days). Bile leak severity was the only independent factor associated with eventual success (P = 0.01). Endoscopic therapy is safe and effective for postoperative bile leak. Bile leak severity is the most important factor influencing successful endoscopic therapy. © 2016 Japan Gastroenterological Endoscopy Society.

  12. Removal of foreign bodies in the upper gastrointestinal tract in adults: European Society of Gastrointestinal Endoscopy (ESGE) Clinical Guideline.

    PubMed

    Birk, Michael; Bauerfeind, Peter; Deprez, Pierre H; Häfner, Michael; Hartmann, Dirk; Hassan, Cesare; Hucl, Tomas; Lesur, Gilles; Aabakken, Lars; Meining, Alexander

    2016-05-01

    This Guideline is an official statement of the European Society of Gastrointestinal Endoscopy (ESGE). It addresses the removal of foreign bodies in the upper gastrointestinal tract in adults. Recommendations Nonendoscopic measures 1 ESGE recommends diagnostic evaluation based on the patient's history and symptoms. ESGE recommends a physical examination focused on the patient's general condition and to assess signs of any complications (strong recommendation, low quality evidence). 2 ESGE does not recommend radiological evaluation for patients with nonbony food bolus impaction without complications. We recommend plain radiography to assess the presence, location, size, configuration, and number of ingested foreign bodies if ingestion of radiopaque objects is suspected or type of object is unknown (strong recommendation, low quality evidence). 3 ESGE recommends computed tomography (CT) scan in all patients with suspected perforation or other complication that may require surgery (strong recommendation, low quality evidence). 4 ESGE does not recommend barium swallow, because of the risk of aspiration and worsening of the endoscopic visualization (strong recommendation, low quality evidence). 5 ESGE recommends clinical observation without the need for endoscopic removal for management of asymptomatic patients with ingestion of blunt and small objects (except batteries and magnets). If feasible, outpatient management is appropriate (strong recommendation, low quality evidence). 6 ESGE recommends close observation in asymptomatic individuals who have concealed packets of drugs by swallowing ("body packing"). We recommend against endoscopic retrieval. We recommend surgical referral in cases of suspected packet rupture, failure of packets to progress, or intestinal obstruction (strong recommendation, low quality evidence). Endoscopic measures 7 ESGE recommends emergent (preferably within 2 hours, but at the latest within 6 hours) therapeutic esophagogastroduodenoscopy for foreign bodies inducing complete esophageal obstruction, and for sharp-pointed objects or batteries in the esophagus. We recommend urgent (within 24 hours) therapeutic esophagogastroduodenoscopy for other esophageal foreign bodies without complete obstruction (strong recommendation, low quality evidence). 8 ESGE suggests treatment of food bolus impaction in the esophagus by gently pushing the bolus into the stomach. If this procedure is not successful, retrieval should be considered (weak recommendation, low quality evidence). The effectiveness of medical treatment of esophageal food bolus impaction is debated. It is therefore recommended, that medical treatment should not delay endoscopy (strong recommendation, low quality evidence). 9 In cases of food bolus impaction, ESGE recommends a diagnostic work-up for potential underlying disease, including histological evaluation, in addition to therapeutic endoscopy (strong recommendation, low quality evidence). 10 ESGE recommends urgent (within 24 hours) therapeutic esophagogastroduodenoscopy for foreign bodies in the stomach such as sharp-pointed objects, magnets, batteries and large/long objects. We suggest nonurgent (within 72 hours) therapeutic esophagogastroduodenoscopy for medium-sized blunt foreign bodies in the stomach (strong recommendation, low quality evidence). 11 ESGE recommends the use of a protective device in order to avoid esophagogastric/pharyngeal damage and aspiration during endoscopic extraction of sharp-pointed foreign bodies. Endotracheal intubation should be considered in the case of high risk of aspiration (strong recommendation, low quality evidence). 12 ESGE suggests the use of suitable extraction devices according to the type and location of the ingested foreign body (weak recommendation, low quality evidence). 13 After successful and uncomplicated endoscopic removal of ingested foreign bodies, ESGE suggests that the patient may be discharged. If foreign bodies are not or cannot be removed, a case-by-case approach depending on the size and type of the foreign body is suggested (weak recommendation, low quality evidence). © Georg Thieme Verlag KG Stuttgart · New York.

  13. Decontamination of minimally invasive surgical endoscopes and accessories.

    PubMed

    Ayliffe, G

    2000-08-01

    (1) Infections following invasive endoscopy are rare and are usually of endogenous origin. Nevertheless, infections do occur due to inadequate cleaning and disinfection and the use of contaminated rinse water and processing equipment. (2) Rigid and flexible operative endoscopes and accessories should be thoroughly cleaned and preferably sterilized using properly validated processes. (3) Heat tolerant operative endoscopes and accessories should be sterilized using a vacuum assisted steam sterilizer. Use autoclavable instrument trays or containers to protect equipment during transit and processing. Small bench top sterilizers without vacuum assisted air removal are unsuitable for packaged and lumened devices. (4) Heat sensitive rigid and flexible endoscopes and accessories should preferably be sterilized using ethylene oxide, low temperature steam and formaldehyde (rigid only) or gas plasma (if appropriate). (5) If there are insufficient instruments or time to sterilize invasive endoscopes, or if no suitable method is available locally, they may be disinfected by immersion in 2% glutaraldehyde or a suitable alternative. An immersion time of at least 10 min should be adopted for glutaraldehyde. This is sufficient to inactivate most vegetative bacteria and viruses including HIV and hepatitis B virus (HBV). Longer contact times of 20 min or more may be necessary if a mycobacterial infection is known or suspected. At least 3 h immersion in glutaraldehyde is required to kill spores. (6) Glutaraldehyde is irritant and sensitizing to the skin, eyes and respiratory tract. Measures must be taken to ensure glutaraldehyde is used in a safe manner, i.e., total containment and/or extraction of harmful vapour and the provision of suitable personal protective equipment, i.e., gloves, apron and eye protection if splashing could occur. Health surveillance of staff is recommended and should include a pre-employment enquiry regarding asthma, skin and mucosal sensitivity problems and lung function testing by spirometry. (7) Possible alternative disinfectants to glutaraldehyde include peracetic acid (0.2-0.35%), chlorine dioxide (700-1100 ppm) and superoxidized water. These are very effective, killing vegetative bacteria, including mycobacteria, and viruses in 5 min and bacterial spores in 10 min. An endorsement of compatibility with endoscopes, accessories and processing equipment is required from both the solution/device manufacturer and the endoscope manufacturer. Other important considerations are stability, cost and safety from the user and environmental standpoints. (8) Cleaning and disinfection or sterilization should be undertaken by trained staff in a dedicated area, e.g., SSD or TSSU. A suitable training programme is described. (9) If endoscopes are processed by immersion in disinfectants, harmful residues must be removed by thorough rinsing. Sterile or bacteria free water is essential for rinsing all invasive endoscopes and accessories to prevent recontamination. (10) If an automated washer disinfector is used it must be effective, non-damaging, reliable, easy to use and its performance regularly monitored. (11) If used, washer disinfectors and other processing equipment should be disinfected on a regular basis, i.e., between patients or at the start of each session. This will prevent biofilm formation and recontamination of instruments during rinsing. Disinfection should include the water treatment system, if present. (12) To comply with the Medical Devices Directive, manufacturers are obliged to provide full details on how to decontaminate the reusable devices they supply. This should include details of compatibility with heat, pressure, moisture, processing chemicals and ultrasonics. (13) The Infection Control Team should always be involved in the formulation and implementation of decontamination policies. Wherever possible, the national good practice guidelines produced by the Medical Devices Agency and/or professional societies shoul

  14. Current trends and pitfalls in endoscopic treatment of urolithiasis.

    PubMed

    Inoue, Takaaki; Okada, Shinsuke; Hamamoto, Shuzo; Yoshida, Takashi; Matsuda, Tadashi

    2018-02-01

    Current development of endoscopic technology, lithotripters, and stone-retrieval devices has expanded the indications for retrograde and antegrade endoscopic therapy in the management of urolithiasis. This technology has also resulted in minimally invasive therapy. As surgeons' experience of endourological procedures with the newer instruments has become integrated, the surgical technique and indications for urolithiasis have also changed in the past few years. The present review provides an overview of endourological procedures for upper urinary tract stones and the key points related to surgical techniques. © 2017 The Japanese Urological Association.

  15. Controversy about Management of Hydrocephalus - Shunt vs. Endoscopic Third Ventriculostomy.

    PubMed

    Kumar, Vikas; Bodeliwala, Shaam; Singh, Daljit

    2017-08-01

    The best management of hydrocephalus is still controversial in the twenty-first century. Shunt treatment for hydrocephalus is the most common procedure performed in neurosurgical practice and is associated with the highest complications rate. But during the last 2 decades, the treatment of hydrocephalus has improved with better shunt devices available today, increased facilities for investigations and newer approaches like endoscopic third ventriculostomy. The recent advances in development of better endoscopes have provided the patient and treating doctor with an option for an alternative surgery for treatment of hydrocephalus.

  16. Sterilization, high-level disinfection, and environmental cleaning.

    PubMed

    Rutala, William A; Weber, David J

    2011-03-01

    Failure to perform proper disinfection and sterilization of medical devices may lead to introduction of pathogens, resulting in infection. New techniques have been developed for achieving high-level disinfection and adequate environmental cleanliness. This article examines new technologies for sterilization and high-level disinfection of critical and semicritical items, respectively, and because semicritical items carry the greatest risk of infection, the authors discuss reprocessing semicritical items such as endoscopes and automated endoscope reprocessors, endocavitary probes, prostate biopsy probes, tonometers, laryngoscopes, and infrared coagulation devices. In addition, current issues and practices associated with environmental cleaning are reviewed. Copyright © 2011. Published by Elsevier Inc.

  17. Thoracoscopic pulmonary resection in two cases using an endoscopic linear stapler and loop ligature.

    PubMed

    Yoshida, K; Fujikawa, T; Nishida, Y; Kushida, N; Okabe, N

    1993-01-01

    Recent advances in rigid endoscopic imaging capabilities, light sources, and instrumentation have dramatically expanded the potential role of laparoscopic and thoracoscopic surgery. Moreover, the recent introduction of an endoscopic linear stapling device and loop ligature has made thoracoscopic pulmonary resection possible. We present herein two cases of peripheral pulmonary lesions which were resected thoracoscopically. Case 1 was a 19-year-old man with a history of recurrent pneumothorax due to a left apical bulla who underwent thoracoscopic lung resection using a new stapling device, and Case 2 was a 46-year-old man with a small pulmonary lesion on the left basal segment (S8) who underwent thoracoscopic lung resection using loop ligature. Postoperatively, there was no evidence of air leak in either patient and both were discharged 6 days after surgery. The technical procedures for thoracoscopic lung resection and the clinical courses of both patients are described in this paper.

  18. Establishment of a biophysical model to optimize endoscopic targeting of magnetic nanoparticles for cancer treatment.

    PubMed

    Roeth, Anjali A; Slabu, Ioana; Baumann, Martin; Alizai, Patrick H; Schmeding, Maximilian; Guentherodt, Gernot; Schmitz-Rode, Thomas; Neumann, Ulf P

    2017-01-01

    Superparamagnetic iron oxide nanoparticles (SPION) may be used for local tumor treatment by coupling them to a drug and accumulating them locally with magnetic field traps, that is, a combination of permanent magnets and coils. Thereafter, an alternating magnetic field generates heat which may be used to release the thermosensitively bound drug and for hyperthermia. Until today, only superficial tumors can be treated with this method. Our aim was to transfer this method into an endoscopic setting to also reach the majority of tumors located inside the body. To find the ideal endoscopic magnetic field trap, which accumulates the most SPION, we first developed a biophysical model considering anatomical as well as physical conditions. Entities of choice were esophageal and prostate cancer. The magnetic susceptibilities of different porcine and rat tissues were measured with a superconducting quantum interference device. All tissues showed diamagnetic behavior. The evaluation of clinical data (computed tomography scan, endosonography, surgical reports, pathological evaluation) of patients gave insight into the topographical relationship between the tumor and its surroundings. Both were used to establish the biophysical model of the tumors and their surroundings, closely mirroring the clinical situation, in which we could virtually design, place and evaluate different electromagnetic coil configurations to find optimized magnetic field traps for each tumor entity. By simulation, we could show that the efficiency of the magnetic field traps can be enhanced by 38-fold for prostate and 8-fold for esophageal cancer. Therefore, our approach of endoscopic targeting is an improvement of the magnetic drug-targeting setups for SPION tumor therapy as it holds the possibility of reaching tumors inside the body in a minimal-invasive way. Future animal experiments must prove these findings in vivo.

  19. Intracorporeal lithotripsy. Update on technology.

    PubMed

    Zheng, W; Denstedt, J D

    2000-05-01

    The number and variety of devices currently available for endoscopic lithotripsy reflect the reality that no single device is ideal in all situations. Although the search for the universal lithotriptor continues, the urologist must consider several factors if faced with the decision of which device to purchase. Perhaps foremost among these factors is the clinical situation with which one commonly deals. For example, although the smaller, flexible probes such as EHL or laser demonstrate considerable utility if used ureteroscopically, the larger stone burden associated with today's percutaneous nephrolithotripsy population often is treated more efficiently with one of the mechanical devices employing a larger, rigid probe, such as ultrasound or the Lithoclast. Similarly, the type and size of endoscopic equipment at one's disposal have a significant impact on which device to purchase or use. There are physical constraints affecting which device may or may not be used, rigid versus flexible endoscope, working channel caliber, and offset versus end-on-port. The skill and experience of the surgeon is also a factor of obvious importance, particularly if one is using a modality with a relatively narrow margin of safety such as EHL. Likewise, the training and experience of nursing personnel is a factor, especially regarding the use of lasers, which require certified personnel who are well versed in laser safety. Finally, in today's environment one must carefully evaluate cost in terms of not only initial capital outlay but also ongoing charges for disposable and maintenance items. Thus, the decision of which device to purchase is complex and requires careful evaluation of all of the previously noted variables. Likewise, if one is fortunate enough to have more than one device available, the decision of which lithotriptor to employ requires a similar decision based on sound surgical judgment.

  20. Analysis of the color rendition of flexible endoscopes

    NASA Astrophysics Data System (ADS)

    Murphy, Edward M.; Hegarty, Francis J.; McMahon, Barry P.; Boyle, Gerard

    2003-03-01

    Endoscopes are imaging devices routinely used for the diagnosis of disease within the human digestive tract. Light is transmitted into the body cavity via incoherent fibreoptic bundles and is controlled by a light feedback system. Fibreoptic endoscopes use coherent fibreoptic bundles to provide the clinician with an image. It is also possible to couple fibreoptic endoscopes to a clip-on video camera. Video endoscopes consist of a small CCD camera, which is inserted into gastrointestinal tract, and associated image processor to convert the signal to analogue RGB video signals. Images from both types of endoscope are displayed on standard video monitors. Diagnosis is dependent upon being able to determine changes in the structure and colour of tissues and biological fluids, and therefore is dependent upon the ability of the endoscope to reproduce the colour of these tissues and fluids with fidelity. This study investigates the colour reproduction of flexible optical and video endoscopes. Fibreoptic and video endoscopes alter image colour characteristics in different ways. The colour rendition of fibreoptic endoscopes was assessed by coupling them to a video camera and applying video colorimetric techniques. These techniques were then used on video endoscopes to assess how the colour rendition of video endoscopes compared with that of optical endoscopes. In both cases results were obtained at fixed illumination settings. Video endoscopes were then assessed with varying levels of illumination. Initial results show that at constant luminance endoscopy systems introduce non-linear shifts in colour. Techniques for examining how this colour shift varies with illumination intensity were developed and both methodology and results will be presented. We conclude that more rigorous quality assurance is required to reduce colour error and are developing calibration procedures applicable to medical endoscopes.

  1. New developments in endoscopic treatment of chronic pancreatitis.

    PubMed

    Didden, P; Bruno, M; Poley, J W

    2012-12-01

    The aim of endoscopic therapy of chronic pancreatitis (CP) is to treat pain by draining the pancreatic duct or managing loco-regional complications. Recent decennia were characterized by continuous improvement of endoscopic techniques and devices, resulting in a better clinical outcome. Novel developments now also provide the opportunity to endoscopically treat refractory CP-related complications. Especially suboptimal surgical candidates could potentially benefit from these new developments, consequently avoiding invasive surgery. The use of fully covered self-expandable metal stents (SEMS) has been explored in pancreatic and CP-related biliary duct strictures, resistant to conventional treatment with plastic endoprotheses. Furthermore, endosonography-guided transmural drainage of the main pancreatic duct via duct-gastrostomy is an alternative treatment option in selected cases. Pancreatic pseudocysts represent an excellent indication for endoscopic therapy with some recent case series demonstrating effective drainage with the use of a fully covered SEMS. Although results of these new endoscopic developments are promising, high quality randomized trials are required to determine their definite role in the management of chronic pancreatitis.

  2. Endoscopic techniques in aesthetic plastic surgery.

    PubMed

    McCain, L A; Jones, G

    1995-01-01

    There has been an explosive interest in endoscopic techniques by plastic surgeons over the past two years. Procedures such as facial rejuvenation, breast augmentation and abdominoplasty are being performed with endoscopic assistance. Endoscopic operations require a complex setup with components such as video camera, light sources, cables and hard instruments. The Hopkins Rod Lens system consists of optical fibers for illumination, an objective lens, an image retrieval system, a series of rods and lenses, and an eyepiece for image collection. Good illumination of the body cavity is essential for endoscopic procedures. Placement of the video camera on the eyepiece of the endoscope gives a clear, brightly illuminated large image on the monitor. The video monitor provides the surgical team with the endoscopic image. It is important to become familiar with the equipment before actually doing cases. Several options exist for staff education. In the operating room the endoscopic cart needs to be positioned to allow a clear unrestricted view of the video monitor by the surgeon and the operating team. Fogging of the endoscope may be prevented during induction by using FREDD (a fog reduction/elimination device) or a warm bath. The camera needs to be white balanced. During the procedure, the nurse monitors the level of dissection and assesses for clogging of the suction.

  3. Quantitative ENT endoscopy: the future in the new millennium

    NASA Astrophysics Data System (ADS)

    Mueller, Andreas; Schubert, Mario

    1999-06-01

    In Otorhinolaryngology the endoscopic appraisal of luminal dimensions of the nose, the throat, the larynx and the trachea is a daily problem. Those concerned with endoscopy know, that endoscopes distort dimensions of examined anatomical structures. To draw conclusions on luminal dimensions from the endoscopic pictures additional measuring devices are required. We developed a new method of measuring luminal dimensions in rigid or flexible endoscopy. For this a laser beam directed radially marks the anatomical lumen of interest in the videoendoscopic vision. The laser ring becomes deformed according to the form of the cavity explored. By keeping the distance defined between the laser ring and the top of the endoscope, the endoscopic video image can be measured. A piece of software developed by us calculates from the pictures the cross sectional area as well as the extension of benign or malign stenosis of the cavity explored. The result of the endoscopic measuring procedure can be visualized 3D on a PC-monitor. We are going to demonstrate the result of our clinical experience in different otorhinolaryngological diseases with the new endoscopic measuring kit in comparison to standard endoscopy. A further perspective is the endoscopic measuring kit in comparison to standard endoscopy. A further perspective is the endoscopic assisted manufacturing (EAM) of anatomical adapted stents, tubes and cannules.

  4. Capsule endoscope localization based on computer vision technique.

    PubMed

    Liu, Li; Hu, Chao; Cai, Wentao; Meng, Max Q H

    2009-01-01

    To build a new type of wireless capsule endoscope with interactive gastrointestinal tract examination, a localization and orientation system is needed for tracking 3D location and 3D orientation of the capsule movement. The magnetic localization and orientation method produces only 5 DOF, but misses the information of rotation angle along capsule's main axis. In this paper, we presented a complementary orientation approach for the capsule endoscope, and the 3D rotation can be determined by applying computer vision technique on the captured endoscopic images. The experimental results show that the complementary orientation method has good accuracy and high feasibility.

  5. Current status of device-assisted enteroscopy: Technical matters, indication, limits and complications

    PubMed Central

    Riccioni, Maria Elena; Urgesi, Riccardo; Cianci, Rossella; Bizzotto, Alessandra; Galasso, Domenico; Costamagna, Guido

    2012-01-01

    Enteroscopy, defined as direct visualization of the small bowel with the use of a fiberoptic or capsule endoscopy, has progressed considerably over the past several years. The need for endoscopic access to improve diagnosis and treatment of small bowel disease has led to the development of novel technologies one of which is non-invasive, the video capsule, and a type of invasive technique, the device-assisted enteroscopy. In particular, the device-assisted enteroscopy consists then of three different types of instruments all able to allow, in skilled hands, to display partially or throughout its extension (if necessary) the small intestine. Newer devices, double balloon, single balloon and spiral endoscopy, are just entering clinical use. The aim of this article is to review recent advances in small bowel enteroscopy, focusing on indications, modifications to improve imaging and techniques, pitfalls, and clinical applications of the new instruments. With new technologies, the trials and tribulations of learning new endoscopic skills and determining their role in the diagnosis and treatment of small bowel disease come. Identification of small bowel lesions has dramatically improved. Studies are underway to determine the best strategy to apply new enteroscopy technologies for the diagnosis and management of small bowel disease, particularly obscure bleeding. Vascular malformations such as angiectasis and small bowel neoplasms as adenocarcinoma or gastrointestinal stromal tumors. Complete enteroscopy of the small bowel is now possible. However, because of the length of the small bowel, endoscopic examination and therapeutic maneuvers require significant skill, radiological assistance, the use of deep sedation with the assistance of the anesthetist. Prospective randomized studies are needed to guide diagnostic testing and therapy with these new endoscopic techniques. PMID:23189216

  6. [Prognostic factors of mortality in the malignant biliary obstruction unresectable after the insertion of an endoscopic stent].

    PubMed

    Hernández Guerrero, Angélica; Sánchez del Monte, Julio; Sobrino Cossío, Sergio; Alonso Lárraga, Octavio; Delgado de la Cruz, Lourdes; Frías Mendívil, M Mauricio; Frías Mendívil, C Mauricio

    2006-01-01

    To determine the factors prognostics of early mortality in the malignant billary estenosis after the endoscopic derivation. The surgical, percutaneous or endoscopic derivation is the alternative of palliative treatment in the biliary obstruction unresectable. The factors prognostic the early mortality after surgical derivation are: hemoglobin < 10 g/dL, serum bilirubin > 10 mg/dL and serum albumin < 2.5 g/dL; for the percutaneous derivation they are the sanguineous urea more of 4.3 mmol/L and hemoglobin < 10.9 g/dL; whereas in the single endoscopic derivation type 3 of Bismuth and the infectious complications after the endoscopic colangiography and the absence of the clinical success were factors prognoses of early mortality. Descriptive and retrospective analysis of 97 cases with malignant biliary obstruction. The factors were evaluated prognoses of early mortality. Univariated and bivaried analysis and of survival by the method of Kaplan-Meier was made curved. 97 cases were included that presented/displayed unresectable disease and had a biochemical control subsequent to the drainage. They were 58 women and 39 men. More frequent symptoms: ictericia, pain and prurito. 61 cases of distal obstruction and 36 with proximal obstruction. Twenty deaths (25.9%) happened within the 30 later days to the treatment. The bilirubin > 14 mg/dL and the proximal location were like predicting of early mortality. The obstruction biliary more frequent is located in choledocho distal and is of pancreatic origin. The main factors associated to early mortality are: the bilirubin > of 14 mg/dL and the proximal location reason why is important the suitable selection of patient candidates to endoscopic derivation. The survival is better in the distal obstruction.

  7. Fluorescence endoscopic video system

    NASA Astrophysics Data System (ADS)

    Papayan, G. V.; Kang, Uk

    2006-10-01

    This paper describes a fluorescence endoscopic video system intended for the diagnosis of diseases of the internal organs. The system operates on the basis of two-channel recording of the video fluxes from a fluorescence channel and a reflected-light channel by means of a high-sensitivity monochrome television camera and a color camera, respectively. Examples are given of the application of the device in gastroenterology.

  8. Surgical evaluation of a novel tethered robotic capsule endoscope using micro-patterned treads.

    PubMed

    Sliker, Levin J; Kern, Madalyn D; Schoen, Jonathan A; Rentschler, Mark E

    2012-10-01

    The state-of-the-art technology for gastrointestinal (GI) tract exploration is a capsule endoscope (CE). Capsule endoscopes are pill-sized devices that provide visual feedback of the GI tract as they move passively through the patient. These passive devices could benefit from a mobility system enabling maneuverability and controllability. Potential benefits of a tethered robotic capsule endoscope (tRCE) include faster travel speeds, reaction force generation for biopsy, and decreased capsule retention. In this work, a tethered CE is developed with an active locomotion system for mobility within a collapsed lumen. Micro-patterned polydimethylsiloxane (PDMS) treads are implemented onto a custom capsule housing as a mobility method. The tRCE housing contains a direct current (DC) motor and gear train to drive the treads, a video camera for visual feedback, and two light sources (infrared and visible) for illumination. The device was placed within the insufflated abdomen of a live anesthetized pig to evaluate mobility performance on a planar tissue surface, as well as within the cecum to evaluate mobility performance in a collapsed lumen. The tRCE was capable of forward and reverse mobility for both planar and collapsed lumen tissue environments. Also, using an onboard visual system, the tRCE was capable of demonstrating visual feedback within an insufflated, anesthetized porcine abdomen. Proof-of-concept in vivo tRCE mobility using micro-patterned PDMS treads was shown. This suggests that a similar method could be implemented in future smaller, faster, and untethered RCEs.

  9. Extended Endoscopic Endonasal Resection of a Suprasellar and Third Ventricular Retrochiasmatic Craniopharyngioma with a Narrow Pituitary Gland-Optic Chiasm Interval: Techniques to Optimize Resection.

    PubMed

    Kenning, Tyler J; Pinheiro-Neto, Carlos D

    2018-04-01

    The extended endoscopic endonasal approach can be utilized to surgically treat pathology within the suprasellar space. This relies on a sufficient corridor and interval between the superior aspect of the pituitary gland and the optic chiasm. Tumors located in the retrochiasmatic space and within the third ventricle, however, may not have a widened interval through which to work. With mass effect on the superior and posterior aspect of the optic chiasm, the corridor between the chiasm and the pituitary gland might even be further narrowed. This may negate the possibility of utilizing the endoscopic endonasal approach for the management of pathology in this location. We present a case of a retrochiasmatic craniopharyngioma with a narrow resection corridor that was treated with the extended endoscopic approach and we review techniques to potentially overcome this limitation. The link to the video can be found at: https://youtu.be/ogRZj-aBqeQ .

  10. Totally endoscopic implant to effect a gastric bypass: 12-month safety and efficacy outcomes.

    PubMed

    Sandler, Bryan J; Biertho, Laurent; Anvari, Mehran; Rumbaut, Roberto; Morales-Garza, Luis Alonso; Torres-Barrera, Gustavo; Marceau, Simon; Hong, Dennis; Smith, C Daniel; Horgan, Santiago

    2018-04-20

    Only a small percentage of candidates for bariatric surgery ever undergo a procedure for weight loss. Devices duplicating key effects of bariatric surgeries with removable, fully trans-oral implants could extend their benefits to patients unwilling to undergo anatomy-altering abdominal surgeries. Thirty-two obese subjects (mean BMI: 42.3) were enrolled in a prospective, multicenter, single-arm, feasibility trial of the first fully trans-oral endoscopic gastrointestinal bypass device. The device is a cuff attached to the distal esophagus by transmural anchors and connected to a 120-cm sleeve diverting undigested nutrients to the jejunum. Bodyweight, vital signs, adverse events, medications, HbA1c, fasting glucose, and lipids were collected at baseline and follow-up visits. Device status was endoscopically assessed every 6 months. The fully trans-oral procedure was successful in all subjects without intraoperative adverse events or postoperative infections. Twenty-eight of 32 subjects (88%) remained implanted with continuing follow-up beyond their 12-month visit. At 12 months, the 32 subjects had lost an average of 44.8% of excess body weight, 17.6% of total body weight, 20.8 kg, and 7.5 BMI points. Weight loss depended on capture of ingesta by the esophageal cuff, with 18 of 32 subjects without visible gaps around their cuffs at the 6 month endoscopy having significantly greater EWL (53.6 vs. 33.4% in the remaining subjects, p < 0.002). Mean HbA1c and fasting glucose declined by 1.1% points and 29 mg/dL in type 2 diabetic subjects, 80% of whom had remission of their diabetes at 12 months. This study demonstrates the feasibility, safety, and efficacy of a fully trans-oral gastrointestinal bypass implant. This purely endoscopic device may provide a valuable addition to the armamentarium of treatment available for the management of morbid obesity.

  11. Arthroscopically assisted reduction of acute acromioclavicular joint dislocation using a single double-button device: Medium-term clinical and radiological outcomes.

    PubMed

    Issa, S-P; Payan, C; Le Hanneur, M; Loriaut, P; Boyer, P

    2018-02-01

    Double-button devices for endoscopic management of acute acromioclavicular joint dislocation (ACJD) provide satisfactory short-term functional and radiological results. However, little exists in the literature regarding the long- and medium-term results of these implants, especially regarding the evolution of the acromioclavicular joint (ACJ). Satisfactory and steady long- and medium-term outcomes can be achieved in patients with acute ACJD undergoing endoscopically assisted ACJ repair using a single double-button device. A retrospective single-center study was conducted in patients with acute Rockwood III and IV ACJD treated endoscopically with a single double-button device from October 2008 to October 2010, allowing a minimum 5-year follow-up. Functional evaluation used Constant and Quick-DASH scores. Clinical evidence of dislocation recurrence was combined with bilateral Zanca views to assess coracoclavicular distance. Acromioclavicular osteoarthritis was evaluated on the Paxinos test and Zanca views. Nineteen of the 25 operated patients were seen at a mean 76.9±8.5 months' follow-up. Mean age was 34.4±8.3 years. Mean Constant and Quick-DASH scores were 96.2±5.1 and 0.9±1.6 points, respectively. Four patients had a recurrence of their initial dislocation, 3 of whom had positive Paxinos test, whereas the 15 patients without recurrence had a negative test (p=0.004). Five patients had radiological evidence of ACJ osteoarthritis: all 4 patients with recurrence and 1 without (p=0.001). Long- and medium-term radioclinical outcome of endoscopically assisted management of acute ACJD using a single double-button device seems to be satisfactory and steady over time. Recurrence of the initial dislocation appears to be related to onset of degenerative ACJ arthropathy. Therapeutic type IV-Retrospective case series. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  12. Dynamic focus-tracking MEMS scanning micromirror with low actuation voltages for endoscopic imaging.

    PubMed

    Strathman, Matthew; Liu, Yunbo; Li, Xingde; Lin, Lih Y

    2013-10-07

    We demonstrate a 3-D scanning micromirror device that combines 2-D beam scanning with focus control in the same device using micro-electro-mechanical-systems (MEMS) technology. 2-D beam scanning is achieved with a biaxial gimbal structure and focus control is obtained with a deformable mirror membrane surface. The micromirror with 800 micrometer diameter is designed to be sufficiently compact and efficient so that it can be incorporated into an endoscopic imaging probe in the future. The design, fabrication and characterization of the device are described in this paper. Using the focus-tracking MEMS scanning mirror, we achieved an optical scanning range of >16 degrees with <40 V actuation voltage at resonance and a tunable focal length between infinity and 25 mm with <100V applied bias.

  13. Method for radiometric calibration of an endoscope's camera and light source

    NASA Astrophysics Data System (ADS)

    Rai, Lav; Higgins, William E.

    2008-03-01

    An endoscope is a commonly used instrument for performing minimally invasive visual examination of the tissues inside the body. A physician uses the endoscopic video images to identify tissue abnormalities. The images, however, are highly dependent on the optical properties of the endoscope and its orientation and location with respect to the tissue structure. The analysis of endoscopic video images is, therefore, purely subjective. Studies suggest that the fusion of endoscopic video images (providing color and texture information) with virtual endoscopic views (providing structural information) can be useful for assessing various pathologies for several applications: (1) surgical simulation, training, and pedagogy; (2) the creation of a database for pathologies; and (3) the building of patient-specific models. Such fusion requires both geometric and radiometric alignment of endoscopic video images in the texture space. Inconsistent estimates of texture/color of the tissue surface result in seams when multiple endoscopic video images are combined together. This paper (1) identifies the endoscope-dependent variables to be calibrated for objective and consistent estimation of surface texture/color and (2) presents an integrated set of methods to measure them. Results show that the calibration method can be successfully used to estimate objective color/texture values for simple planar scenes, whereas uncalibrated endoscopes performed very poorly for the same tests.

  14. Superbugs on Duodenoscopes: the Challenge of Cleaning and Disinfection of Reusable Devices

    PubMed Central

    McDonnell, Gerald

    2015-01-01

    Inadequate flexible endoscope reprocessing has been associated with infection outbreaks, most recently caused by carbapenem-resistant Enterobacteriaceae. Lapses in essential device reprocessing steps such as cleaning, disinfection/sterilization, and storage have been reported, but some outbreaks have occurred despite claimed adherence to established guidelines. Recommended changes in these guidelines include the use of sterilization instead of high-level disinfection or the use of routine microbial culturing to monitor efficacy of reprocessing. This review describes the current standards for endoscope reprocessing, associated outbreaks, and the complexities associated with both microbiological culture and sterilization approaches to mitigating the risk of infection associated with endoscopy. PMID:26202125

  15. Feasibility study of Tethered Capsule Endomicroscopy (TCE) deployment in the small intestine (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Otuya, David O.; Verma, Yogesh; Dong, Jing; Gora, Michalina J.; Tearney, Guillermo J.

    2017-02-01

    Environmental enteric dysfunction (EED) is a poorly understood disease of the small intestine that causes nutrient malabsorption in children, predominantly from low and middle income countries. The clinical importance of EED is neurological and growth stunting that remains as the child grows into adulthood. Tethered capsule endomicroscopy (TCE) has the potential to improve the understanding of EED and could be used to determine the effectiveness of EED interventions. TCE in the adult esophagus and the duodenum has been demonstrated for Barrett`s esophagus and celiac disease diagnosis, respectively. While adult subjects can independently swallow these capsules, it is likely that infants will not, and, as a result, new strategies for introducing these devices in young children aged 0.5-2 years need to be investigated. Our first approach will be to introduce the TCE devices in infants under the aid of endoscopic guidance. To determine the most effective method, we have tested endoscopic approaches for introducing TCE devices into the small intestine of living swine. These methods will be compared and contrasted to discuss the most effective means for endoscopic tethered capsule introduction into the small intestine.

  16. Laparoscopic-endoscopic cooperative surgery is a safe and effective treatment for superficial nonampullary duodenal tumors.

    PubMed

    Kyuno, Daisuke; Ohno, Keisuke; Katsuki, Shinichi; Fujita, Tomoki; Konno, Ai; Murakami, Takeshi; Waga, Eriko; Takanashi, Kunihiro; Kitaoka, Keisuke; Komatsu, Yuya; Sasaki, Kazuaki; Hirata, Koichi

    2015-11-01

    The use of endoscopic submucosal dissection (ESD) for duodenal neoplasms has increased in recent years, but delayed perforation and bleeding are also known to frequently occur. We present two cases in which duodenal adenoma was successfully treated with laparoscopic-endoscopic cooperative surgery. ESD was combined with laparoscopic seromuscular sutures. The lesions in both cases were located in the second portion of the duodenum. The patients requested resection of the lesion, and we performed laparoscopic-endoscopic cooperative surgery. After the laparoscopic surgeon mobilized the duodenum, the endoscopic surgeon performed ESD for the duodenal tumor without perforation. The laparoscopic surgeon sutured the duodenal wall in the seromuscular layer to strengthen the ulcer bed after ESD. Histopathological studies confirmed that the surgical margins were tumor-free in both cases. The patients were discharged with no complications. This unique laparoscopic-endoscopic cooperative procedure is a safe and effective method for resecting superficial nonampullary duodenal tumors. © 2015 Japan Society for Endoscopic Surgery, Asia Endosurgery Task Force and Wiley Publishing Asia Pty Ltd.

  17. Electrokinetically pumped high pressure sprays

    DOEpatents

    Schoeniger, Joseph S [Oakland, CA; Paul, Phillip H [Livermore, CA; Schoeniger, Luke [Pittsford, NY

    2005-11-01

    An electrokinetic pump capable of producing high pressure is combined with a nozzle having a submicron orifice to provide a high pressure spray device. Because of its small size, the device can be contained within medical devices such as an endoscope for delivering biological materials such as DNA, chemo therapeutic agents, or vaccines to tissues and cells.

  18. Electrokinetically pumped high pressure sprays

    DOEpatents

    Schoeniger, Joseph S.; Paul, Phillip H.; Schoeniger, Luke

    2002-01-01

    An electrokinetic pump capable of producing high pressure is combined with a nozzle having a submicron orifice to provide a high pressure spray device. Because of its small size, the device can be contained within medical devices such as an endoscope for delivering biological materials such as DNA, chemo therapeutic agents, or vaccines to tissues and cells.

  19. Endoscopic submucosal dissection using flexknife.

    PubMed

    Kodashima, Shinya; Fujishiro, Mitsuhiro; Yahagi, Naohisa; Kakushima, Naomi; Omata, Masao

    2006-01-01

    Although the standard treatment for early-stage gastrointestinal tumors is still surgical resection, endoscopic resection has been accepted for some of these lesions, especially in Japan. However, the indication was limited until recently to achieve en bloc resection and prevent local recurrence. To overcome the disadvantage of endoscopic resection with conventional endoscopic mucosal resection (EMR), several investigators, including us, have developed a new endoscopic resection technique: endoscopic submucosal dissection (ESD). ESD is a remarkable technique that enables to remove the lesions en bloc regardless of size, shape, coexisting ulcer, and location. Nowadays, several knives are available for ESD, such as the needle knife, insulation-tipped (IT) knife, Hookknife, triangle-tipped (TT) knife, and Flexknife. Each of them has some merits and demerits, and the ways to use the knives are different. We summarize here how to use the Flexknife, which we made ourselves in cooperation with the Olympus Company, and how we use the technique in our hospital.

  20. On localizing a capsule endoscope using magnetic sensors.

    PubMed

    Moussakhani, Babak; Ramstad, Tor; Flåm, John T; Balasingham, Ilangko

    2012-01-01

    In this work, localizing a capsule endoscope within the gastrointestinal tract is addressed. It is assumed that the capsule is equipped with a magnet, and that a magnetic sensor network measures the flux from this magnet. We assume no prior knowledge on the source location, and that the measurements collected by the sensors are corrupted by thermal Gaussian noise only. Under these assumptions, we focus on determining the Cramer-Rao Lower Bound (CRLB) for the location of the endoscope. Thus, we are not studying specific estimators, but rather the theoretical performance of an optimal one. It is demonstrated that the CRLB is a function of the distance and angle between the sensor network and the magnet. By studying the CRLB with respect to different sensor array constellations, we are able to indicate favorable constellations.

  1. Total radiated power, infrared output, and heat generation by cold light sources at the distal end of endoscopes and fiber optic bundle of light cables.

    PubMed

    Hensman, C; Hanna, G B; Drew, T; Moseley, H; Cuschieri, A

    1998-04-01

    Skin burns and ignition of drapes have been reported with the use of cold light sources. The aim of the study was to document the temperature generated by cold light sources and to correlate this with the total radiated power and infrared output. The temperature, total radiated power, and infrared output were measured as a function of time at the end of the endoscope (which is inserted into the operative field) and the end of the fiber optic bundle of the light cable (which connects the cable to the light port of the endoscope) using halogen and xenon light sources. The highest temperature recorded at the end of the endoscope was 95 degrees C. The temperature measured at the optical fiber location of the endoscope was higher than at its lens surface (p < 0.0001). At the end of the fiber optic bundle of light cables, the temperature reached 225 degrees C within 15 s. The temperature recorded at the optical fiber location of all endoscopes and light cables studied rose significantly over a period of 10 min to reach its maximum (p <0.0001) and then leveled off for the duration of the study (30 min). The infrared output accounted only for 10% of the total radiated power. High temperatures are reached by 10 min at the end of fiber optic bundle of light cables and endoscopes with both halogen and xenon light sources. This heat generation is largely due to the radiated power in the visible light spectrum.

  2. Advances in endoscopic management of biliary complications after living donor liver transplantation: Comprehensive review of the literature

    PubMed Central

    Shin, Milljae; Joh, Jae-Won

    2016-01-01

    Apart from noticeable improvements in surgical techniques and immunosuppressive agents, biliary complications remain the major causes of morbidity and mortality after living donor liver transplantation (LDLT). Bile leakage and stricture are the predominant complications. The reported incidence of biliary complications is 15%-40%, and these are known to occur more frequently in living donors than in deceased donors. Despite the absence of a confirmed therapeutic algorithm, many approaches have been used for treatment, including surgical, endoscopic, and percutaneous transhepatic techniques. In recent years, nonsurgical approaches have largely replaced reoperation. Among these, the endoscopic approach is currently the preferred initial treatment for patients who undergo duct-to-duct biliary reconstruction. Previously, endoscopic management was achieved most optimally through balloon dilatation and single or multiple stents placement. Recently, there have been significant developments in endoscopic devices, such as novel biliary stents, as well as advances in endoscopic technologies, including deep enteroscopy, the rendezvous technique, magnetic compression anastomosis, and direct cholangioscopy. These developments have resulted in almost all patients being managed by the endoscopic approach. Multiple recent publications suggest superior long-term results, with overall success rates ranging from 58% to 75%. This article summarizes the advances in endoscopic management of patients with biliary complications after LDLT. PMID:27468208

  3. A wireless narrowband imaging chip for capsule endoscope.

    PubMed

    Lan-Rong Dung; Yin-Yi Wu

    2010-12-01

    This paper presents a dual-mode capsule gastrointestinal endoscope device. An endoscope combined with a narrowband image (NBI), has been shown to be a superior diagnostic tool for early stage tissue neoplasms detection. Nevertheless, a wireless capsule endoscope with the narrowband imaging technology has not been presented in the market up to now. The narrowband image acquisition and power dissipation reduction are the main challenges of NBI capsule endoscope. In this paper, we present the first narrowband imaging capsule endoscope that can assist clinical doctors to effectively diagnose early gastrointestinal cancers, profited from our dedicated dual-mode complementary metal-oxide semiconductor (CMOS) sensor. The dedicated dual-mode CMOS sensor can offer white-light and narrowband images. Implementation results show that the proposed 512 × 512 CMOS sensor consumes only 2 mA at a 3-V power supply. The average current of the NBI capsule with an 8-Mb/s RF transmitter is nearly 7 ~ 8 mA that can continuously work for 6 ~ 8 h with two 1.5-V 80-mAh button batteries while the frame rate is 2 fps. Experimental results on backside mucosa of a human tongue and pig's small intestine showed that the wireless NBI capsule endoscope can significantly improve the image quality, compared with a commercial-of-the-shelf capsule endoscope for gastrointestinal tract diagnosis.

  4. Automated processing of endoscopic surgical instruments.

    PubMed

    Roth, K; Sieber, J P; Schrimm, H; Heeg, P; Buess, G

    1994-10-01

    This paper deals with the requirements for automated processing of endoscopic surgical instruments. After a brief analysis of the current problems, solutions are discussed. Test-procedures have been developed to validate the automated processing, so that the cleaning results are guaranteed and reproducable. Also a device for testing and cleaning was designed together with Netzsch Newamatic and PCI, called TC-MIC, to automate processing and reduce manual work.

  5. Development of Bariatric and Metabolic Endoscopy

    PubMed Central

    Li, Shi-Han; Wang, Yong-Jun; Zhang, Shu-Tian

    2018-01-01

    Objective: With the evolution of society and changes in human lifestyle, obesity is becoming increasingly prevalent worldwide, and obesity-related comorbidities such as diabetes, hyperlipidemia, hypertension, and coronary heart disease are more common. As a result, new devices and methods for bariatric and metabolic endoscopy are being developed for clinical use, offering new options for patients. This review discussed the progress in bariatric and metabolic endoscopy. Data Sources: This review was based on data in articles published in the PubMed database up to September 2017, with the following keywords: “obesity”, “endoscopy”, “weight loss”, and “metabolism”. Study Selection: Original articles about various endoscopic methods of weight loss and other reviews of bariatric and metabolic endoscopy were included and analyzed. Results: The technology of bariatric and metabolic endoscopy has advanced rapidly in recent years. The intragastric balloon (IGB), with its comparatively long period of development, is the most mature and widely used instrument. Multiple new endoscopic devices have been created in recent years, with different targets to achieve weight loss. Despite the proliferation of new devices, the lack of clinical data results in a shortage of clinical experience and instruction in the use of this new equipment. Conclusions: Bariatric and metabolic endoscopy would help obese people lose weight or prepare for bariatric surgery and hopefully alleviate some of the complications of bariatric procedures. Adequate studies and data are still needed for the new endoscopic devices. PMID:29271386

  6. Endoscopic ultrasound-guided biliary drainage

    PubMed Central

    Chavalitdhamrong, Disaya; Draganov, Peter V

    2012-01-01

    Endoscopic ultrasound (EUS)-guided biliary drainage has emerged as a minimally invasive alternative to percutaneous and surgical interventions for patients with biliary obstruction who had failed endoscopic retrograde cholangiopancreatography (ERCP). EUS-guided biliary drainage has become feasible due to the development of large channel curvilinear therapeutic echo-endoscopes and the use of real-time ultrasound and fluoroscopy imaging in addition to standard ERCP devices and techniques. EUS-guided biliary drainage is an attractive option because of its minimally invasive, single step procedure which provides internal biliary decompression. Multiple investigators have reported high success and low complication rates. Unfortunately, high quality prospective data are still lacking. We provide detailed review of the use of EUS for biliary drainage from the perspective of practicing endoscopists with specific focus on the technical aspects of the procedure. PMID:22363114

  7. Endoscopic OCT for in-vivo imaging of precancer and cancer states of human mucosa

    NASA Astrophysics Data System (ADS)

    Sergeev, Alexander M.; Gelikonov, Valentin M.; Gelikonov, Grigory V.; Feldchtein, Felix I.; Kuranov, Roman V.; Gladkova, Natalia D.; Shakhova, Natalia M.; Kuznetzova, Irina N.; Snopova, Ludmila; Denisenko, Arkady; Almasov, Valentin

    1998-01-01

    First results of endoscopic applications of optical coherence tomography for in vivo studies of human mucosa in gastrointestinal and genital tracts are presented. A novel endoscopic OCT system has ben created that is based on the integration of a sampling arm of an all-optical-fiber interferometer into standard endoscopic devices using their biopsy channel to transmit low-coherence radiation to investigated tissue. We have studied mucous membranes of esophagus, stomach and uterine cervix as typical localization for carcinomatous processes. Images of tumor tissues versus healthy tissues have been recorded and analyzed. Violations of well-defined stratified healthy mucosa structure in cancerous tissue is distinctly seen by EOCT, thus making this technique promising for early diagnosis of tumors and precise guiding of excisional biopsy.

  8. Wireless Power Transfer to Millimeter-Sized Gastrointestinal Electronics Validated in a Swine Model

    PubMed Central

    Abid, Abubakar; O’Brien, Jonathan M.; Bensel, Taylor; Cleveland, Cody; Booth, Lucas; Smith, Brian R.; Langer, Robert; Traverso, Giovanni

    2017-01-01

    Electronic devices placed in the gastrointestinal (GI) tract for prolonged periods have the potential to transform clinical evaluation and treatment. One challenge to the deployment of such gastroresident electronics is the difficulty in powering millimeter-sized electronics devices without using batteries, which compromise biocompatibility and long-term residence. We examined the feasibility of leveraging mid-field wireless powering to transfer power from outside of the body to electronics at various locations along the GI tract. Using simulations and ex vivo measurements, we designed mid-field antennas capable of operating efficiently in tissue at 1.2 GHz. These antennas were then characterized in vivo in five anesthetized pigs, by placing one antenna outside the body, and the other antenna inside the body endoscopically, at the esophagus, stomach, and colon. Across the animals tested, mean transmission efficiencies of −41.2, −36.1, and −34.6 dB were achieved in vivo while coupling power from outside the body to the esophagus, stomach, and colon, respectively. This corresponds to power levels of 37.5 μW, 123 μW and 173 μW received by antennas in the respective locations, while keeping radiation exposure levels below safety thresholds. These power levels are sufficient to wirelessly power a range of medical devices from outside of the body. PMID:28447624

  9. Initial design of a novel suction enteroscope for endoscopic locomotion in the small bowel (with video).

    PubMed

    Wagh, Mihir S; Montane, Roberto

    2012-02-01

    The upper GI tract and the colon are readily accessible endoscopically, but the small intestine is relatively difficult to evaluate. To demonstrate the feasibility of using suction as a means of locomotion and to assess the initial design of a suction enteroscope. Feasibility study. Animal laboratory. Various prototype suction devices designed in our laboratory were tested in swine small intestine in a force test station. For in vivo experiments in live anesthetized animals, two suction devices (1 fixed tip and 1 movable tip) were attached to the outside of the endoscope. By creating suction in the fixed tip, the endoscope was anchored while the movable tip was advanced. Suction was then applied to the extended tip to attach it to the distal bowel. Suction on the fixed tip was then released and the movable tip with suction pulled back, resulting in advancement of the endoscope. These steps were sequentially repeated. Intestinal segments were sent for pathologic assessment after testing. Force generated ranged from 0.278 to 4.74 N with 64.3 to 88 kPa vacuum pressure. A linear relationship was seen between the pull force and vacuum pressures and tip surface area. During in vivo experiments, the endoscope was advanced in 25-cm segmental increments with sequential suction-and-release maneuvers. No significant bowel trauma was seen on pathology and necropsy. The enteroscopy system requires further refinement. A novel suction enteroscope was designed and tested. Suction tip characteristics played a critical role impacting the functionality of this enteroscopy system. Copyright © 2012 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  10. Endoscopic Findings and Clinical Outcomes in Ventricular Assist Device Recipients with Gastrointestinal Bleeding

    PubMed Central

    Elmunzer, B. Joseph; Padhya, Kunjali T.; Lewis, Jason J.; Rangnekar, Amol S.; Saini, Sameer D.; Eswaran, Shanti L.; Scheiman, James M.; Pagani, Francis D.; Haft, Jonathan W.; Waljee, Akbar K.

    2015-01-01

    Background Gastrointestinal bleeding (GIB) is an important clinical problem in recipients of ventricular assist devices (VAD), although data pertaining to the endoscopic evaluation and management of this complication are limited in the medical literature. Aims We sought to identify the most common endoscopic findings in VAD recipients with GIB, and to better define the diagnostic and therapeutic utility of endosopy for this patient population. Methods Twenty-six subjects with VAD and overt GIB were retrospectively identified. Clinical and endoscopic data were abstracted for each subject on to standardized forms in duplicate and independent fashion. Raw data and descriptive statistics were reported. Results Non-peptic vascular lesions were the most common cause of GIB. A definitive cause of bleeding was identified by endoscopy in almost 60% of subjects. Endoscopic hemostasis was achieved in 14/15 patients in whom bleeding did not stop spontaneously. Rebleeding occurred in 50% of subjects and was successfully retreated or stopped spontaneously in all cases. Colonoscopy did not establish a definitive diagnosis or deliver hemostatic therapy in any case. Conclusions Vascular malformations account for the overwhelming majority of bleeding lesions in VAD patients with GIB. Endoscopy seems to be a safe and effective tool for diagnosing, risk stratifying, and treating this patient population, although multiple endoscopies may be necessary before therapeutic success, and the incidence of rebleeding is high. A prospective multi-center registry is necessary to establish evidence-based management algorithms for VAD recipients with GIB. PMID:21792619

  11. Endoscopic cystoventriculostomy and ventriculocysternostomy using a recently developed 2.0-micron fiber-guided high-power diode-pumped solid state laser in children with hydrocephalus

    NASA Astrophysics Data System (ADS)

    Ludwig, Hans C.; Kruschat, Thomas; Knobloch, Torsten; Rostasy, Kevin; Buchfelder, Michael

    2005-04-01

    Preterm infants have a high incidence of post hemorrhagic or post infectious hydrocephalus often associated with ventricular or arachnoic cysts which carry a high risk of entrapment of cerebrospinal fluid (CSF). In these cases fenestration and opening of windows within the separating membranes are neurosurgical options. Although Nd:YAG- and diode-lasers have already been used in neuroendoscopic procedures, neurosurgeons avoid the use of high energy lasers in proximity to vital structures because of potential side effects. We have used a recently developed diode pumped solid state (DPSS) laser emitting light at a wavelength of 2.0 μm (Revolix TM LISA laser products, Katlenburg, Germany), which can be delivered through silica fibres towards endoscopic targets. From July 2002 until June 2004 fourteen endoscopic procedures in 12 consecutive patients (age 3 months to 12 years old) were performed. Most children suffered from complex post hemorrhagic and post infectious hydrocephalus, in whom ventriculoperitoneal shunt devices failed to restore a CSF equilibrium due to entrapment of CSF pathways by the cysts. We used two different endoscopes, a 6 mm Neuroendoscope (Braun Aesculap, Melsungen, Germany; a 4 mm miniature Neuroscope (Storz, Tuttlingen, Germany). The endoscopes were connected to a standard camera and TV monitor, the laser energy was introduced through a 365 μm core diameter bare ended silica fibre (PercuFib, LISA laser products, Katlenburg, Germany) through the endoscope"s working channel. The continuous wave laser was operated at power levels from 5 to 15 Watt in continuous and chopped mode. The frequency of the laser in chopped mode was varied between 5 and 20 Hz. All patients tolerated the procedure well. No immediate or long term side effects were noted. In 3 patients with cystic compression of the 4th ventricle, insertion of a shunt device could be avoided. The authors conclude that the use of the new RevolixTM laser enables safe and effective procedures in neuroendoscopy.

  12. Robotics in endoscopy.

    PubMed

    Klibansky, David; Rothstein, Richard I

    2012-09-01

    The increasing complexity of intralumenal and emerging translumenal endoscopic procedures has created an opportunity to apply robotics in endoscopy. Computer-assisted or direct-drive robotic technology allows the triangulation of flexible tools through telemanipulation. The creation of new flexible operative platforms, along with other emerging technology such as nanobots and steerable capsules, can be transformational for endoscopic procedures. In this review, we cover some background information on the use of robotics in surgery and endoscopy, and review the emerging literature on platforms, capsules, and mini-robotic units. The development of techniques in advanced intralumenal endoscopy (endoscopic mucosal resection and endoscopic submucosal dissection) and translumenal endoscopic procedures (NOTES) has generated a number of novel platforms, flexible tools, and devices that can apply robotic principles to endoscopy. The development of a fully flexible endoscopic surgical toolkit will enable increasingly advanced procedures to be performed through natural orifices. The application of platforms and new flexible tools to the areas of advanced endoscopy and NOTES heralds the opportunity to employ useful robotic technology. Following the examples of the utility of robotics from the field of laparoscopic surgery, we can anticipate the emerging role of robotic technology in endoscopy.

  13. The Combination Therapy of Dissolution Using Carbonated Liquid and Endoscopic Procedure for Bezoars: Pragmatical and Clinical Review

    PubMed Central

    Ogawa, Kohei; Mizuno, Ken-ichi; Shinagawa, Yoko; Kobayashi, Yuji; Abe, Hiroyuki; Watanabe, Yukari; Takahashi, Shunsaku; Hayashi, Kazunao; Yokoyama, Junji; Takeuchi, Manabu; Yamagiwa, Satoshi; Sato, Yuichi; Terai, Shuji

    2016-01-01

    Bezoars are relatively rare foreign bodies of gastrointestinal tract and often cause ileus and ulcerative lesions in the stomach and subsequent bleeding and perforation due to their size and stiffness. Therefore, the removal of bezoars is essential and recent development of devices, the endoscopic removal procedure, is often applied. However, due to their stiffness, simple endoscopic removal failed in not a few cases, and surgical removal has also been used. Recently, the efficacy of a combination therapy of endoscopic procedure and dissolution using carbonated liquid has been reported. To develop the safe and effective removal procedure, we carefully reviewed a total of 55 reported cases in this study including our 3 additional cases, successfully treated with dissolution with endoscopic fragmentation. In summary, the data showed the efficiency in the combination therapy, treating the larger size of bezoar and reducing the length of hospital stay. To the best of our knowledge, this is the largest pragmatical and clinical review for the combination therapy of dissolution and endoscopic treatment for bezoars. This review should help physicians to manage bezoars more efficiently. PMID:27642293

  14. Dynamic focus-tracking MEMS scanning micromirror with low actuation voltages for endoscopic imaging

    PubMed Central

    Strathman, Matthew; Liu, Yunbo; Li, Xingde; Lin, Lih Y.

    2013-01-01

    We demonstrate a 3-D scanning micromirror device that combines 2-D beam scanning with focus control in the same device using micro-electro-mechanical-systems (MEMS) technology. 2-D beam scanning is achieved with a biaxial gimbal structure and focus control is obtained with a deformable mirror membrane surface. The micromirror with 800 micrometer diameter is designed to be sufficiently compact and efficient so that it can be incorporated into an endoscopic imaging probe in the future. The design, fabrication and characterization of the device are described in this paper. Using the focus-tracking MEMS scanning mirror, we achieved an optical scanning range of >16 degrees with <40 V actuation voltage at resonance and a tunable focal length between infinity and 25 mm with <100V applied bias. PMID:24104304

  15. Endoscopic Management of Foreign Bodies in the Upper Gastrointestinal Tract of Adults

    PubMed Central

    Yao, Chih-Chien; Wu, I-Ting; Lu, Lung-Sheng; Lin, Sheng-Chieh; Liang, Chih-Ming; Kuo, Yuan-Hung; Yang, Shih-Cheng; Wu, Cheng-Kun; Wang, Hsing-Ming; Kuo, Chung-Huang; Chiou, Shue-Shian; Wu, Keng-Liang; Chiu, Yi-Chun; Chuah, Seng-Kee; Tai, Wei-Chen

    2015-01-01

    Background. Foreign object ingestion and food bolus impaction are a common clinical problem. We report our clinical experiences in endoscopic management for adults, foreign body ingestion, and food bolus impaction. Method. A retrospective chart review study was conducted on adult patients with foreign body ingestion and food bolus impaction between January 2011 and November 2014. Patients with incomplete medical records were excluded. Results. A total of 198 patients (226 incidents) were included in the study (male/female: 1.54/1; age 57 ± 16 years). Among them, 168 foreign bodies were found successfully (74.3%). 75.6% of the foreign bodies were located in the esophagus. Food bolus impaction was most common (41.6%). 93.5% of foreign bodies in current study cohort were successfully extracted and 5 patients required surgical interventions. Comparisons between symptomatic and asymptomatic patients revealed that locations of foreign bodies in the pharynx and esophagus were the significant relevant factors (P < 0.001). Shorter time taken to initiate endoscopic interventions increased detection rate (289.75 ± 465.94 versus 471.06 ± 659.93 minutes, P = 0.028). Conclusion. Endoscopic management is a safe and highly effective procedure in extracting foreign body ingestion and food bolus impaction. Prompt endoscopic interventions can increase the chance of successful foreign bodies' detection. PMID:26258140

  16. Endoscopic Management of Foreign Bodies in the Upper Gastrointestinal Tract of Adults.

    PubMed

    Yao, Chih-Chien; Wu, I-Ting; Lu, Lung-Sheng; Lin, Sheng-Chieh; Liang, Chih-Ming; Kuo, Yuan-Hung; Yang, Shih-Cheng; Wu, Cheng-Kun; Wang, Hsing-Ming; Kuo, Chung-Huang; Chiou, Shue-Shian; Wu, Keng-Liang; Chiu, Yi-Chun; Chuah, Seng-Kee; Tai, Wei-Chen

    2015-01-01

    Foreign object ingestion and food bolus impaction are a common clinical problem. We report our clinical experiences in endoscopic management for adults, foreign body ingestion, and food bolus impaction. A retrospective chart review study was conducted on adult patients with foreign body ingestion and food bolus impaction between January 2011 and November 2014. Patients with incomplete medical records were excluded. A total of 198 patients (226 incidents) were included in the study (male/female: 1.54/1; age 57 ± 16 years). Among them, 168 foreign bodies were found successfully (74.3%). 75.6% of the foreign bodies were located in the esophagus. Food bolus impaction was most common (41.6%). 93.5% of foreign bodies in current study cohort were successfully extracted and 5 patients required surgical interventions. Comparisons between symptomatic and asymptomatic patients revealed that locations of foreign bodies in the pharynx and esophagus were the significant relevant factors (P < 0.001). Shorter time taken to initiate endoscopic interventions increased detection rate (289.75 ± 465.94 versus 471.06 ± 659.93 minutes, P = 0.028). Endoscopic management is a safe and highly effective procedure in extracting foreign body ingestion and food bolus impaction. Prompt endoscopic interventions can increase the chance of successful foreign bodies' detection.

  17. Effects of geared motor characteristics on tactile perception of tissue stiffness.

    PubMed

    Longnion, J; Rosen, J; Sinanan, M; Hannaford, B

    2001-01-01

    Endoscopic haptic surgical devices have shown promise in addressing the loss of tactile sensation associated with minimally invasive surgery. However, these devices must be capable of generating forces and torques similar to those applied on the tissue with a standard endoscopic tool. Geared motors are a possible solution for actuation; however, they possess mechanical characteristics that could potentially interfere with tactile perception of tissue qualities. The aim of the current research was to determine how the characteristics of a geared motor suitable for a haptic surgical device affect a user's perception of stiffness. The experiment involved six blindfolded subjects who were asked to discriminate the stiffness of six distinct silicone rubber samples whose mechanical properties are similar to those of soft tissue. Using a novel testing device whose dimensions approximated those of an endoscopic grasper, each subject palpated 30 permutations of sample pairs for each of three types of mechanical loads; the motor (friction and inertia), a flywheel (with the same inertia as motor), and a control (no significant mechanical interference). One factor ANOVA of the error scores and palpation time showed that no significant difference existed among error scores, but mean palpation time for the control was significantly less than for the other two methods. These results indicated that the mechanical characteristics of a geared motor chosen for application in a haptic surgical device did not interfere with the subjects' perception of the silicone samples' stiffness, but these characteristics may significantly affect the energy expenditure and time required for tissue palpation. Therefore, before geared motors can be considered for use in haptic surgical devices, consideration should be given to factors such as palpation speed and fatigue.

  18. Light distributor for endoscopic photochemotherapy of tumors.

    PubMed

    Lenz, P

    1987-10-15

    This device is fixed to the extremity of an optical fiber and permits light to spread over tumors situated inside hollow organs accessible by endoscopes. Compared to currently used diffusing tips, light distributors have several advantages, in particular precise matching of the irradiated area to the target area, high transmission efficiency, high power density favoring therapeutically relevant hyperthermia, and great mechanical resistance. The clinical usefulness of light distributors has been demonstrated.

  19. Results from the commissioning of a multi-modal endoscope for ultrasound and time of flight PET

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bugalho, Ricardo

    2015-07-01

    The EndoTOFPET-US collaboration has developed a multi-modal imaging system combining Ultrasound with Time-of-Flight Positron Emission Tomography into an endoscopic imaging device. The objective of the project is to obtain a coincidence time resolution of about 200 ps FWHM and to achieve about 1 mm spatial resolution of the PET system, while integrating all the components in a very compact detector suitable for endoscopic use. This scanner aims to be exploited for diagnostic and surgical oncology, as well as being instrumental in the clinical test of new biomarkers especially targeted for prostate and pancreatic cancer. (authors)

  20. Superbugs on Duodenoscopes: the Challenge of Cleaning and Disinfection of Reusable Devices.

    PubMed

    Humphries, Romney M; McDonnell, Gerald

    2015-10-01

    Inadequate flexible endoscope reprocessing has been associated with infection outbreaks, most recently caused by carbapenem-resistant Enterobacteriaceae. Lapses in essential device reprocessing steps such as cleaning, disinfection/sterilization, and storage have been reported, but some outbreaks have occurred despite claimed adherence to established guidelines. Recommended changes in these guidelines include the use of sterilization instead of high-level disinfection or the use of routine microbial culturing to monitor efficacy of reprocessing. This review describes the current standards for endoscope reprocessing, associated outbreaks, and the complexities associated with both microbiological culture and sterilization approaches to mitigating the risk of infection associated with endoscopy. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  1. Technical feasibility of patient-friendly screening and treatment of digestive disease by remote control robotic capsule endoscopes via the internet.

    PubMed

    Ohta, Hidetoshi; Kawashima, Makoto

    2014-01-01

    A few types of steerable capsule endoscopes have been proposed but disappointingly their systems were not applicable to common endoscopic treatment or pathological diagnosis. This study validates the possibility of treatment and biopsy by using an internet-linked (wireless control via the internet) robotic capsule endoscope (iRoboCap). iRoboCap consisted of three parts: an imaging unit, a movement control unit and a therapeutic tool unit. Two types of iRoboCaps were designed, one was a submarine type (iRoboCap-S) and the other was an amphibious type (iRoboCap-A). They were remotely and wirelessly steered by a portable tablet device using Bluetooth and via the internet. The success rates of biopsy or clipping were evaluated in a phantom. Although the two prototypes have various problems that need improving, we hope that our robotic and wireless innovations have opened the door to new endoscopic procedures and will pioneer various new applications in medicine.

  2. Intestinal biomechanics simulator for robotic capsule endoscope validation.

    PubMed

    Slawinski, Piotr R; Oleynikov, Dmitry; Terry, Benjamin S

    2015-01-01

    This work describes the development and validation of a novel device which simulates important forces experienced by Robotic Capsule Endoscopes (RCE) in vivo in the small intestine. The purpose of the device is to expedite and lower the cost of RCE development. Currently, there is no accurate in vitro test method nor apparatus to validate new RCE designs; therefore, RCEs are tested in vivo at a cost of ∼$1400 per swine test. The authors have developed an in vitro RCE testing device which generates two peristaltic waves to accurately simulate the two biomechanical actions of the human small intestine that are most relevant to RCE locomotion: traction force and contact force. The device was successfully calibrated to match human physiological ranges for traction force (4-40 gf), contact force (80-500 gf) and peristaltic wave propagation speed (0.08-2 cm s(-1)) for a common RCE capsule geometry of 3.5 cm length and 1.5 cm diameter.

  3. Automatic localization of endoscope in intraoperative CT image: A simple approach to augmented reality guidance in laparoscopic surgery.

    PubMed

    Bernhardt, Sylvain; Nicolau, Stéphane A; Agnus, Vincent; Soler, Luc; Doignon, Christophe; Marescaux, Jacques

    2016-05-01

    The use of augmented reality in minimally invasive surgery has been the subject of much research for more than a decade. The endoscopic view of the surgical scene is typically augmented with a 3D model extracted from a preoperative acquisition. However, the organs of interest often present major changes in shape and location because of the pneumoperitoneum and patient displacement. There have been numerous attempts to compensate for this distortion between the pre- and intraoperative states. Some have attempted to recover the visible surface of the organ through image analysis and register it to the preoperative data, but this has proven insufficiently robust and may be problematic with large organs. A second approach is to introduce an intraoperative 3D imaging system as a transition. Hybrid operating rooms are becoming more and more popular, so this seems to be a viable solution, but current techniques require yet another external and constraining piece of apparatus such as an optical tracking system to determine the relationship between the intraoperative images and the endoscopic view. In this article, we propose a new approach to automatically register the reconstruction from an intraoperative CT acquisition with the static endoscopic view, by locating the endoscope tip in the volume data. We first describe our method to localize the endoscope orientation in the intraoperative image using standard image processing algorithms. Secondly, we highlight that the axis of the endoscope needs a specific calibration process to ensure proper registration accuracy. In the last section, we present quantitative and qualitative results proving the feasibility and the clinical potential of our approach. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Comparison of endoscope- versus microscope-assisted resection of deep-seated intracranial lesions using a minimally invasive port retractor system.

    PubMed

    Hong, Christopher S; Prevedello, Daniel M; Elder, J Bradley

    2016-03-01

    Tubular brain retractors may improve access to deep-seated brain lesions while potentially reducing the risks of collateral neurological injury associated with standard microsurgical approaches. Here, microscope-assisted resection of lesions using tubular retractors is assessed to determine if it is superior to endoscope-assisted surgery due to the technological advancements associated with modern tubular ports and surgical microscopes. Following institutional approval of the tubular port, data obtained from the initial 20 patients to undergo transportal resection of deep-seated brain lesions were analyzed in this study. The pathological entities of the resected tissues included metastatic tumors (8 patients), glioma (7), meningioma (1), neurocytoma (1), radiation necrosis (1), primitive neuroectodermal tumor (1), and hemangioblastoma (1). Surgery incorporated endoscopic (5 patients) or microscopic (15) assistance. The locations included the basal ganglia (11 patients), cerebellum (4), frontal lobe (2), temporal lobe (2), and parietal lobe (1). Cases were reviewed for neurological outcomes, extent of resection (EOR), and complications. Technical data for the port, surgical microscope, and endoscope were analyzed. EOR was considered total in 14 (70%), near total (> 95%) in 4 (20%), and subtotal (< 90%) in 2 (10%) of 20 patients. Incomplete resection was associated with the basal ganglia location (p < 0.05) and use of the endoscope (p < 0.002). Four of 5 (80%) endoscope-assisted cases were near-total (2) or subtotal (2) resection. Histopathological diagnosis, presenting neurological symptoms, and demographics were not associated with EOR. Complication rates were low and similar between groups. Initial experience with tubular retractors favors use of the microscope rather than the endoscope due to a wider and 3D field of view. Improved microscope optics and tubular retractor design allows for binocular vision with improved lighting for the resection of deep-seated brain lesions.

  5. Endoscopic removal of over-the-scope clips using a novel cutting device: a retrospective case series.

    PubMed

    Schmidt, Arthur; Riecken, Bettina; Damm, Michael; Cahyadi, Oscar; Bauder, Markus; Caca, Karel

    2014-09-01

    Over-the-scope clips (OTSCs; Ovesco Endoscopy, Tübingen, Germany) are extensively used for treatment of gastrointestinal perforations, leakages, fistulas, and bleeding. In this report, a new method of removing OTSCs using a prototype bipolar cutting device is described. A total of 11 patients underwent endoscopic removal of an OTSC. The OTSC was cut at two opposing sites by a prototype device (DC ClipCutter; Ovesco Endoscopy). The remaining clip fragments were extracted using a standard forceps. Mean procedure time was 47 minutes (range 35 - 75 minutes). Cutting of the OTSC at two opposing sites was successful in all cases (100 %). Complete retrieval of all clip fragments was possible in 10 patients (91 %). The overall success rate for cutting and complete removal of the clip was 91 %. No major complications were observed. Removal of OTSCs with the prototype device was feasible and effective. The device may be valuable for OTSC removal in emergency as well as elective indications. © Georg Thieme Verlag KG Stuttgart · New York.

  6. Combined Endoscopic and Laparoscopic Management of Postcholecystectomy Mirizzi Syndrome from a Remnant Cystic Duct Stone: Case Report and Review of the Literature

    PubMed Central

    Amin, Arpit; Zhurov, Yuriy; Ibrahim, George; Maffei, Anthony; Giannone, Jonathan; Cerabona, Thomas; Kaul, Ashutosh

    2016-01-01

    Mirizzi syndrome has been defined in the literature as common bile duct obstruction resulting from calculi within Hartmann's pouch or cystic duct. We present a case of a 78-year-old female, who developed postcholecystectomy Mirizzi syndrome from a remnant cystic duct stone. Diagnosis of postcholecystectomy Mirizzi syndrome was made on endoscopic retrograde cholangiography (ERCP) performed postoperatively. The patient was treated with a novel strategy by combining advanced endoscopic and laparoscopic techniques in three stages as follows: Stage 1 (initial presentation): endoscopic sphincterotomy with common bile duct stent placement; Stage 2 (6 weeks after Stage 1): laparoscopic ultrasonography to locate the remnant cystic duct calculi followed by laparoscopic retrieval of the calculi and intracorporeal closure of cystic duct stump; Stage 3 (6 weeks after Stage 2): endoscopic removal of common bile duct stent along with performance of completion endoscopic retrograde cholangiogram. In addition, we have performed an extensive review of the various endoscopic and laparoscopic management techniques described in the literature for the treatment of postcholecystectomy syndrome occurring from retained cystic duct stones. PMID:27047698

  7. Combined Endoscopic and Laparoscopic Management of Postcholecystectomy Mirizzi Syndrome from a Remnant Cystic Duct Stone: Case Report and Review of the Literature.

    PubMed

    Amin, Arpit; Zhurov, Yuriy; Ibrahim, George; Maffei, Anthony; Giannone, Jonathan; Cerabona, Thomas; Kaul, Ashutosh

    2016-01-01

    Mirizzi syndrome has been defined in the literature as common bile duct obstruction resulting from calculi within Hartmann's pouch or cystic duct. We present a case of a 78-year-old female, who developed postcholecystectomy Mirizzi syndrome from a remnant cystic duct stone. Diagnosis of postcholecystectomy Mirizzi syndrome was made on endoscopic retrograde cholangiography (ERCP) performed postoperatively. The patient was treated with a novel strategy by combining advanced endoscopic and laparoscopic techniques in three stages as follows: Stage 1 (initial presentation): endoscopic sphincterotomy with common bile duct stent placement; Stage 2 (6 weeks after Stage 1): laparoscopic ultrasonography to locate the remnant cystic duct calculi followed by laparoscopic retrieval of the calculi and intracorporeal closure of cystic duct stump; Stage 3 (6 weeks after Stage 2): endoscopic removal of common bile duct stent along with performance of completion endoscopic retrograde cholangiogram. In addition, we have performed an extensive review of the various endoscopic and laparoscopic management techniques described in the literature for the treatment of postcholecystectomy syndrome occurring from retained cystic duct stones.

  8. In vivo endoscopic OCT imaging of precancer and cancer states of human mucosa

    NASA Astrophysics Data System (ADS)

    Sergeev, Alexander M.; Gelikonov, V. M.; Gelikonov, G. V.; Feldchtein, Felix I.; Kuranov, R. V.; Gladkova, N. D.; Shakhova, N. M.; Snopova, L. B.; Shakhov, A. V.; Kuznetzova, I. A.; Denisenko, A. N.; Pochinko, V. V.; Chumakov, Yu P.; Streltzova, O. S.

    1997-12-01

    First results of endoscopic applications of optical coherence tomography for in vivo studies of human mucosa in respiratory, gastrointestinal, urinary and genital tracts are presented. A novel endoscopic OCT (EOCT) system has been created that is based on the integration of a sampling arm of an all-optical-fiber interferometer into standard endoscopic devices using their biopsy channel to transmit low-coherence radiation to investigated tissue. We have studied mucous membranes of esophagus, larynx, stomach, urinary bladder, uterine cervix and body as typical localization for carcinomatous processes. Images of tumor tissues versus healthy tissues have been recorded and analyzed. Violations of well-defined stratified healthy mucosa structure in cancered tissue are distinctly seen by EOCT, thus making this technique promising for early diagnosis of tumors and precise guiding of excisional biopsy.

  9. Integrated endoscopic OCT system and in-vivo images of human internal organs

    NASA Astrophysics Data System (ADS)

    Sergeev, Alexander M.; Gelikonov, Valentin M.; Gelikonov, Grigory V.; Feldchtein, Felix I.; Kuranov, Roman V.; Gladkova, Natalia D.; Shakhova, Natalia M.; Snopova, Ludmila; Shakhov, Andrei; Kuznetzova, Irina N.; Denisenko, Arkady; Pochinko, Vitaly; Chumakov, Yuri; Almasov, Valentin

    1998-04-01

    First results of endoscopic applications of optical coherence tomography (OCT) for in vivo studies of human mucosa in respiratory, gastrointestinal, urinary and genital tracts are presented. A novel endoscopic OCT (EOCT) system has been created that is based on the integration of a sampling arm of an all-optical-fiber interferometer into standard endoscopic devices using their biopsy channel to transmit low-coherence radiation to investigated tissue. We have studied mucous membranes of esophagus, larynx, stomach, urinary bladder, uterine cervix and endometrium as typical localization for carcinomatous processes. Images of tumor tissues versus healthy tissues have been recorded and analyzed. Violations of well-defined stratified healthy mucosa structure in cancered tissue is distinctly seen by EOCT, thus making this technique promising for early diagnosis of tumors and precise guiding of excisional biopsy.

  10. Real-time endoscopic image orientation correction system using an accelerometer and gyrosensor.

    PubMed

    Lee, Hyung-Chul; Jung, Chul-Woo; Kim, Hee Chan

    2017-01-01

    The discrepancy between spatial orientations of an endoscopic image and a physician's working environment can make it difficult to interpret endoscopic images. In this study, we developed and evaluated a device that corrects the endoscopic image orientation using an accelerometer and gyrosensor. The acceleration of gravity and angular velocity were retrieved from the accelerometer and gyrosensor attached to the handle of the endoscope. The rotational angle of the endoscope handle was calculated using a Kalman filter with transmission delay compensation. Technical evaluation of the orientation correction system was performed using a camera by comparing the optical rotational angle from the captured image with the rotational angle calculated from the sensor outputs. For the clinical utility test, fifteen anesthesiology residents performed a video endoscopic examination of an airway model with and without using the orientation correction system. The participants reported numbers written on papers placed at the left main, right main, and right upper bronchi of the airway model. The correctness and the total time it took participants to report the numbers were recorded. During the technical evaluation, errors in the calculated rotational angle were less than 5 degrees. In the clinical utility test, there was a significant time reduction when using the orientation correction system compared with not using the system (median, 52 vs. 76 seconds; P = .012). In this study, we developed a real-time endoscopic image orientation correction system, which significantly improved physician performance during a video endoscopic exam.

  11. Posterior Percutaneous Endoscopic Cervical Foraminotomy and Diskectomy With Unilateral Biportal Endoscopy.

    PubMed

    Park, Jae Hyun; Jun, Su Gi; Jung, Je Tae; Lee, Sang Jin

    2017-09-01

    This report describes a new, minimally invasive procedure, posterior percutaneous endoscopic cervical diskectomy, performed with a unilateral biportal endoscopic approach. The procedure is used to treat cervical foraminal soft disk protrusion. This report also describes the short-term results with this procedure. In 2015, 14 patients underwent this new, minimally invasive procedure. The technique was applied with a standard arthroscopy device and conventional spine instruments. The Neck Disability Index and visual analog scale scores for the neck and upper arm were evaluated, and 13 consecutive patients were included in the analysis. Mean follow-up was 14.8 months (range, 12-18 months). The Neck Disability Index decreased from 27.0±2.5 to 6.8±1.4 at the last follow-up (P<.05). Visual analog scale scores for the neck and upper arm also decreased significantly (neck, 6.2±0.8 to 2.4±0.9; upper arm, 7.0±1.1 to 2.2±0.6). Posterior percutaneous endoscopic cervical diskectomy with a uniportal endoscope provides a clear operative field because of continuous endoscopic saline irrigation and requires only a short hospitalization and no postoperative rehabilitation. Posterior percutaneous endoscopic cervical diskectomy with a unilateral biportal endoscopic approach also can be performed efficiently because of the wide field of visualization and familiar surgical field. Thus, posterior percutaneous endoscopic cervical diskectomy with the unilateral biportal endoscopic approach may be an alternative procedure for cervical foraminal soft disk protrusion. [Orthopedics. 2017; 40(5):e779-e783.]. Copyright 2017, SLACK Incorporated.

  12. Hot biopsy forceps vs. endoscopic ultrasonography in determining the depth of gastric epithelial neoplasia: a simple novel method to decide whether or not to perform endoscopic submucosal dissection.

    PubMed

    Huikai, Li; Enqiang, Linghu

    2013-01-01

    It is of vital importance to determine the depth of lesions to be treated by endoscopic submucosal dissection. This study aimed to compare the accuracy of using hot biopsy forceps method with endoscopic ultrasonography for determination of the depth of gastric epithelial neoplasia. Hot biopsy forceps method and/or endoscopic ultrasonography were used to determine the depth of lesions in 27 patients. With hot biopsy forceps method, we assumed a lesion completely lifted up by a hot biopsy forceps to be confined to the mucosal layer, and one partly lifted up to be located beyond the mucosal layer. The accuracy of hot biopsy forceps method and endoscopic ultrasonography in determining the depth of lesions were compared. Of the 27 patients, 25 underwent endoscopic submucosal dissection and 2 underwent surgery. The total accuracy of hot biopsy forceps method in determining the depth of lesions was 92.6% and that of endoscopic ultrasonography was 81.8%. Overestimation of hot biopsy forceps method and endoscopic ultrasonography were 3.7% vs. 13.6%, respectively. The sensitivity and the specificity of hot biopsy forceps method were 95.5% and 80.0% and those of EUS were 83.3% and 75.0%. Hot biopsy forceps method has a trend towards higher accuracy and lower overestimation than endoscopic ultrasonography.

  13. Calibration procedures of the Tore-Supra infrared endoscopes

    NASA Astrophysics Data System (ADS)

    Desgranges, C.; Jouve, M.; Balorin, C.; Reichle, R.; Firdaouss, M.; Lipa, M.; Chantant, M.; Gardarein, J. L.; Saille, A.; Loarer, T.

    2018-01-01

    Five endoscopes equipped with infrared cameras working in the medium infrared range (3-5 μm) are installed on the controlled thermonuclear fusion research device Tore-Supra. These endoscopes aim at monitoring the plasma facing components surface temperature to prevent their overheating. Signals delivered by infrared cameras through endoscopes are analysed and used on the one hand through a real time feedback control loop acting on the heating systems of the plasma to decrease plasma facing components surface temperatures when necessary, on the other hand for physics studies such as determination of the incoming heat flux . To ensure these two roles a very accurate knowledge of the absolute surface temperatures is mandatory. Consequently the infrared endoscopes must be calibrated through a very careful procedure. This means determining their transmission coefficients which is a delicate operation. Methods to calibrate infrared endoscopes during the shutdown period of the Tore-Supra machine will be presented. As they do not allow determining the possible transmittances evolution during operation an in-situ method is presented. It permits the validation of the calibration performed in laboratory as well as the monitoring of their evolution during machine operation. This is possible by the use of the endoscope shutter and a dedicated plasma scenario developed to heat it. Possible improvements of this method are briefly evoked.

  14. Investigation of in-body path loss in different human subjects for localization of capsule endoscope.

    PubMed

    Ara, Perzila; Cheng, Shaokoon; Heimlich, Michael; Dutkiewicz, Eryk

    2015-01-01

    Recent developments in capsule endoscopy have highlighted the need for accurate techniques to estimate the location of a capsule endoscope. A highly accurate location estimation of a capsule endoscope in the gastrointestinal (GI) tract in the range of several millimeters is a challenging task. This is mainly because the radio-frequency signals encounter high loss and a highly dynamic channel propagation environment. Therefore, an accurate path-loss model is required for the development of accurate localization algorithms. This paper presents an in-body path-loss model for the human abdomen region at 2.4 GHz frequency. To develop the path-loss model, electromagnetic simulations using the Finite-Difference Time-Domain (FDTD) method were carried out on two different anatomical human models. A mathematical expression for the path-loss model was proposed based on analysis of the measured loss at different capsule locations inside the small intestine. The proposed path-loss model is a good approximation to model in-body RF propagation, since the real measurements are quite infeasible for the capsule endoscopy subject.

  15. Development of the local magnification method for quantitative evaluation of endoscope geometric distortion

    NASA Astrophysics Data System (ADS)

    Wang, Quanzeng; Cheng, Wei-Chung; Suresh, Nitin; Hua, Hong

    2016-05-01

    With improved diagnostic capabilities and complex optical designs, endoscopic technologies are advancing. As one of the several important optical performance characteristics, geometric distortion can negatively affect size estimation and feature identification related diagnosis. Therefore, a quantitative and simple distortion evaluation method is imperative for both the endoscopic industry and the medical device regulatory agent. However, no such method is available yet. While the image correction techniques are rather mature, they heavily depend on computational power to process multidimensional image data based on complex mathematical model, i.e., difficult to understand. Some commonly used distortion evaluation methods, such as the picture height distortion (DPH) or radial distortion (DRAD), are either too simple to accurately describe the distortion or subject to the error of deriving a reference image. We developed the basic local magnification (ML) method to evaluate endoscope distortion. Based on the method, we also developed ways to calculate DPH and DRAD. The method overcomes the aforementioned limitations, has clear physical meaning in the whole field of view, and can facilitate lesion size estimation during diagnosis. Most importantly, the method can facilitate endoscopic technology to market and potentially be adopted in an international endoscope standard.

  16. Transnasal endoscopic resection of a nasopharyngeal pleomorphic adenoma: a rare case report.

    PubMed

    Martínez-Capoccioni, Gabriel; Martín-Martín, Carlos; Espinosa-Restrepo, Federico

    2012-08-01

    Pleomorphic adenoma (PA) is the most common benign tumor of the major and minor salivary glands, but rarely found in the nasopharynx. A PA originating from the left lateral wall of the nasopharynx was found in a 52-year-old female who presented with nasal obstruction, left-side otalgia, aural fullness, tinnitus and subjective hearing loss. It was successfully removed by transnasal endoscopic surgery (TES) and navigator system assessed our location, due to the proximity of critical anatomic structures such as the left internal carotid. We believe that the TES for primary and recurrent nasopharyngeal benign tumors is feasible and safe in properly selected patients, due to superior functional and cosmetic results and a low complication rate. Tumor characteristics and location should be taken into account when selecting cases for the right procedure for this lesions; transnasal endoscopic surgery is safe and preferable, carrying less potential morbidity compared to open procedures.

  17. Surgical risk factors for recurrence of inverted papilloma.

    PubMed

    Healy, David Y; Chhabra, Nipun; Metson, Ralph; Holbrook, Eric H; Gray, Stacey T

    2016-04-01

    To identify variations in surgical technique that impact the recurrence of inverted papilloma following endoscopic excision. Retrospective cohort. Data from 127 consecutive patients who underwent endoscopic excision of inverted papilloma and oncocytic papilloma at a tertiary care medical center from 1998 to 2011 were reviewed. Patient demographics, comorbidities, tumor stage, and intraoperative details, including tumor location and management of the base, were evaluated to identify factors associated with tumor recurrence. Recurrence of papilloma occurred in 16 patients (12.6%). Mean time to recurrence was 31.0 months (range, 5.2-110.0 months). Mucosal stripping alone was associated with a recurrence rate of 52.2% (12/23 patients), compared to 4.9% (3/61 patients) when the tumor base was drilled, 4.7% (1/21 patients) when it was cauterized, and 0.0% (0/22 patients) when it was completely excised (P = .001). Increased recurrence rate was associated with tumors located in the maxillary sinus (P = .03), as well as the performance of endoscopic medial maxillectomy (P = .001) and external frontal approaches (P = .02). Drilling, cauterizing, or completely excising the bone underlying the tumor base during endoscopic resection reduces the recurrence rate of inverted and oncocytic papilloma, when compared to mucosal stripping alone. Surgeons who perform endoscopic resection of these tumors should consider utilization of these techniques when possible. 4. © 2015 The American Laryngological, Rhinological and Otological Society, Inc.

  18. Effectiveness of a reusable low-cost balloon trocar dissection device in the creation of preperitoneal space during endoscopic surgery. An experimental study in swine.

    PubMed

    Nácul, Miguel Prestes; Cavazzola, Leandro Totti; Loureiro, Marcelo de Paula; Bonin, Eduardo Aimoré; Ferreira, Paulo Roberto Walter

    2015-09-01

    To evaluate a new, low-cost, reusable balloon trocar device for dissection of the preperitoneal space during endoscopic surgery. Twenty swine (weight: 15-37 kg) were randomized to two groups, according to whether the preperitoneal space was created with a new balloon device manufactured by Bhio-Supply (group B) or with the commercially available OMSPDB 1000® balloon device manufactured by Covidien (group C). Quality and size of the created preperitoneal space, identification of anatomic structures, balloon dissection time, total procedure time, balloon resistance and internal pressure after insufflation with 300 mL of ambient air, balloon-related complications, and procedure cost were assessed. No significant differences in dissection time, total procedure time, or size of the created preperitoneal space were found between the groups. Balloons in group B had a significantly higher internal pressure compared to balloons in group C. None of the balloons ruptured during the experiment. Three animals in group C had balloon-related peritoneal lacerations. Despite a higher individual device cost, group B had a lower procedure cost over the entire experiment. The new balloon device is not inferior to the commercially available device in terms of the safety and effectiveness for creating a preperitoneal space in swine.

  19. A novel semi-automatic snake robot for natural orifice transluminal endoscopic surgery: preclinical tests in animal and human cadaver models (with video).

    PubMed

    Son, Jaebum; Cho, Chang Nho; Kim, Kwang Gi; Chang, Tae Young; Jung, Hyunchul; Kim, Sung Chun; Kim, Min-Tae; Yang, Nari; Kim, Tae-Yun; Sohn, Dae Kyung

    2015-06-01

    Natural orifice transluminal endoscopic surgery (NOTES) is an emerging surgical technique. We aimed to design, create, and evaluate a new semi-automatic snake robot for NOTES. The snake robot employs the characteristics of both a manual endoscope and a multi-segment snake robot. This robot is inserted and retracted manually, like a classical endoscope, while its shape is controlled using embedded robot technology. The feasibility of a prototype robot for NOTES was evaluated in animals and human cadavers. The transverse stiffness and maneuverability of the snake robot appeared satisfactory. It could be advanced through the anus as far as the peritoneal cavity without any injury to adjacent organs. Preclinical tests showed that the device could navigate the peritoneal cavity. The snake robot has advantages of high transverse force and intuitive control. This new robot may be clinically superior to conventional tools for transanal NOTES.

  20. Airway Management During Upper GI Endoscopic Procedures: State of the Art Review.

    PubMed

    Goudra, Basavana; Singh, Preet Mohinder

    2017-01-01

    With the growing popularity of propofol mediated deep sedation for upper gastrointestinal (GI) endoscopic procedures, challenges are being felt and appreciated. Research suggests that management of the airway is anything but routine in this setting. Although many studies and meta-analyses have demonstrated the safety of propofol sedation administered by registered nurses under the supervision of gastroenterologists (likely related to the lighter degrees of sedation than those provided by anesthesia providers and is under medicolegal controversy in the United States), there is no agreement on the optimum airway management for procedures such as endoscopic retrograde cholangiopancreatography. Failure to rescue an airway at an appropriate time has led to disastrous consequences. Inability to evaluate and appreciate the risk factors for aspiration can ruin the day for both the patient and the health care providers. This review apprises the reader of various aspects of airway management relevant to the practice of sedation during upper GI endoscopy. New devices and modification of existing devices are discussed in detail. Recognizing the fact that appropriate monitoring is important for timely recognition and management of potential airway disasters, these issues are explored thoroughly.

  1. Endonasal Suturing of Nasoseptal Flap to Nasopharyngeal Fascia Using the V-Loc™ Wound Closure Device: 2-Dimensional Operative Video.

    PubMed

    Zwagerman, Nathan T; Geltzeiler, Mathew N; Wang, Eric W; Fernandez-Miranda, Juan C; Snyderman, Carl H; Gardner, Paul A

    2018-05-30

    We present a case of cerebrospinal fluid (CSF) leak after endoscopic endonasal resection of a large clival chordoma in an obese patient. The leak was at the lower reconstruction at the craniocervical junction and had failed repositioning. Using the V-Loc™ wound closure device (Covidien, New Haven, Connecticut) to suture the nasoseptal flap to the nasopharyngeal fascia, a water-tight seal was created and, along with a lumbar drain, the patient healed successfully.CSF leak after an endoscopic endonasal approach (EEA) to intradural pathologies remains one of the more common complications.1-4 Various closure techniques have been developed5-8 with success in mitigating this risk, but all have their limitations and rely on multiple layers including vascularized flaps like the nasoseptal flap.9-11 Endonasal suturing of graft materials offers the advantage of creating a water-tight seal. We present the use of the V-Loc™ wound closure device (Covidien) to successfully seal a postoperative CSF leak. The absorbable V-Loc™ wound closure device does not require the surgeon to tie knots, which is the most challenging step in a deep, 2-dimensional corridor. The suture is barbed and is anchored by threading the needle through a prefabricated loop at the end of the suture which locks in place. Each throw of the suture through tissue maintains the suture line as the barbs catch the tissue and prevent retraction. After successful closure, the needle can simply be cut off.The V-Loc™ wound closure device (Covidien) is a safe and effective adjunct to reconstruction after endoscopic endonasal skull base surgery as it provides an option for graft/flap suturing.A written release from the patient whose name or likeness is submitted as part of this Work is on file.

  2. Development and validation of an algorithm to complete colonoscopy using standard endoscopes in patients with prior incomplete colonoscopy

    PubMed Central

    Rogers, Melinda C.; Gawron, Andrew; Grande, David; Keswani, Rajesh N.

    2017-01-01

    Background and study aims  Incomplete colonoscopy may occur as a result of colon angulation (adhesions or diverticulosis), endoscope looping, or both. Specialty endoscopes/devices have been shown to successfully complete prior incomplete colonoscopies, but may not be widely available. Radiographic or other image-based evaluations have been shown to be effective but may miss small or flat lesions, and colonoscopy is often still indicated if a large lesion is identified. The purpose of this study was to develop and validate an algorithm to determine the optimum endoscope to ensure completion of the examination in patients with prior incomplete colonoscopy. Patients and methods  This was a prospective cohort study of 175 patients with prior incomplete colonoscopy who were referred to a single endoscopist at a single academic medical center over a 3-year period from 2012 through 2015. Colonoscopy outcomes from the initial 50 patients were used to develop an algorithm to determine the optimal standard endoscope and technique to achieve cecal intubation. The algorithm was validated on the subsequent 125 patients. Results  The overall repeat colonoscopy success rate using a standard endoscope was 94 %. The initial standard endoscope specified by the algorithm was used and completed the colonoscopy in 90 % of patients. Conclusions  This study identifies an effective strategy for completing colonoscopy in patients with prior incomplete examination, using widely available standard endoscopes and an algorithm based on patient characteristics and reasons for prior incomplete colonoscopy. PMID:28924595

  3. Endoscopic endonasal approaches for the management of skull base meningiomas. Selection criteria and clinical outcomes.

    PubMed

    Todeschini, Alexandre B; Otto, Bradley A; Carrau, Ricardo L; Prevedello, Daniel M

    2018-05-28

    Meningiomas are the most common primary intracranial tumor, arising from different locations, including the skull base. Despite advances in adjuvant treatments, surgical resection remains the main and best treatment for meningiomas. New surgical strategies, such as the endoscopic endonasal approach, have greatly contributed in achieving maximum and total safe resection, preserving the patient's neurological function. Based on the senior authors large experience and a review of the current literature, we have compiled this chapter. We review the surgical technique used at our institution and the most relevant aspects of patient selection when considering resecting a skull base meningioma using the the EEA. Further consideration is given to some skull base meningiomas arising from specific locations with some case examples. The EEA is not an ideal approach for every skull base meningioma. Careful evaluation of the surrounding neurovascular structures surrounding the tumor is imperative to select the appropriate surgical corridor for a safe resection. Nevertheless, for appropriately selected cases, the endoscopic technique is a very valuable tool with some evidences of being superior to the microscopic transcranial approach. A dual-trained surgeon, in both endoscopic and transcranial approaches, is the best alternative to achieve the best patient outcome.

  4. Does stereo-endoscopy improve neurosurgical targeting in 3rd ventriculostomy?

    NASA Astrophysics Data System (ADS)

    Abhari, Kamyar; de Ribaupierre, Sandrine; Peters, Terry; Eagleson, Roy

    2011-03-01

    Endoscopic third ventriculostomy is a minimally invasive surgical technique to treat hydrocephalus; a condition where patients suffer from excessive amounts of cerebrospinal fluid (CSF) in the ventricular system of their brain. This technique involves using a monocular endoscope to locate the third ventricle, where a hole can be made to drain excessive fluid. Since a monocular endoscope provides only a 2D view, it is difficult to make this perforation due to the lack of monocular cues and depth perception. In a previous study, we had investigated the use of a stereo-endoscope to allow neurosurgeons to locate and avoid hazardous areas on the surface of the third ventricle. In this paper, we extend our previous study by developing a new methodology to evaluate the targeting performance in piercing the hole in the membrane. We consider the accuracy of this surgical task and derive an index of performance for a task which does not have a well-defined position or width of target. Our performance metric is sensitive and can distinguish between experts and novices. We make use of this metric to demonstrate an objective learning curve on this task for each subject.

  5. [Experience of Fusion image guided system in endonasal endoscopic surgery].

    PubMed

    Wen, Jingying; Zhen, Hongtao; Shi, Lili; Cao, Pingping; Cui, Yonghua

    2015-08-01

    To review endonasal endoscopic surgeries aided by Fusion image guided system, and to explore the application value of Fusion image guided system in endonasal endoscopic surgeries. Retrospective research. Sixty cases of endonasal endoscopic surgeries aided by Fusion image guided system were analysed including chronic rhinosinusitis with polyp (n = 10), fungus sinusitis (n = 5), endoscopic optic nerve decompression (n = 16), inverted papilloma of the paranasal sinus (n = 9), ossifying fibroma of sphenoid bone (n = 1), malignance of the paranasal sinus (n = 9), cerebrospinal fluid leak (n = 5), hemangioma of orbital apex (n = 2) and orbital reconstruction (n = 3). Sixty cases of endonasal endoscopic surgeries completed successfully without any complications. Fusion image guided system can help to identify the ostium of paranasal sinus, lamina papyracea and skull base. Fused CT-CTA images, or fused MR-MRA images can help to localize the optic nerve or internal carotid arteiy . Fused CT-MR images can help to detect the range of the tumor. It spent (7.13 ± 1.358) minutes for image guided system to do preoperative preparation and the surgical navigation accuracy reached less than 1mm after proficient. There was no device localization problem because of block or head set loosed. Fusion image guided system make endonasal endoscopic surgery to be a true microinvasive and exact surgery. It spends less preoperative preparation time, has high surgical navigation accuracy, improves the surgical safety and reduces the surgical complications.

  6. Multiband mucosectomy for advanced dysplastic lesions in the upper digestive tract

    PubMed Central

    Espinel, Jesús; Pinedo, Eugenia; Ojeda, Vanesa; del Rio, Maria Guerra

    2015-01-01

    Endoscopic resection (ER) is at present an accepted treatment for superficial gastrointestinal neoplasia. ER provides similar efficacy to surgery; however, it is minimally invasive and less expensive. Endoscopic mucosal resection (EMR) is superior to biopsy for diagnosing advanced dysplasia and can change the diagnostic grade and the management. Several EMR techniques have been described that are alternatively used dependent upon the endoscopist personal experience, the anatomic conditions and the endoscopic appearance of the lesion to be resected. The literature suggests that EMR offers comparable outcomes to surgery for selected indications. EMR techniques using a cap fitted endoscope and EMR using a ligation device [multiband mucosectomy (MBM)] are the most frequently use. MBM technique does not require submucosal injection as with the endoscopic resection-cap technique, multiple resections can be performed with the same snare, pre-looping the endoscopic resection-snare in the ridge of the cap is not necessary, MBM does not require withdrawal of the endoscope between resections and up to six consecutive resections can be performed. This reduces the time and cost required for the procedure, while also reducing patient discomfort. Despite the increasing popularity of MBM, data on the safety and efficacy of this technique in upper gastrointestinal lesions with advanced dysplasia, defined as those lesions that have high-grade dysplasia or early cancer, is limited. PMID:25901216

  7. Clinical performance of dental fiberscope image guided system for endodontic treatment.

    PubMed

    Yamazaki, Yasushi; Ogawa, Takumi; Shigeta, Yuko; Ikawa, Tomoko; Kasama, Shintaro; Hattori, Asaki; Suzuki, Naoki; Yamamoto, Takatsugu; Ozawa, Toshiko; Arai, Takashi

    2011-01-01

    We developed a dental fiberscope that can be navigated. As a result we are able to better grasp the device position relative to the teeth, aiming at the lesion more precisely. However, the device position and the precise target setting were difficult to consistently ascertain. The aim of this study is to navigate the position of tip of the dental fiberscope fiber in the root canal with our navigation system. A 3D tooth model was made from the raw dental CT data. In addition, the optical position of the measurement device, OPTOTRAK system was used for registration of the 3D model and actual teeth position and to chase the scope movement. We developed exclusive software to unify information. We were subsequently able to precisely indicate the relation of the position between the device and the teeth on the 3D model in the monitor. This allowed us to aim at the lesion more precisely, as the revised endoscopic image matched the 3D model. The application of this endoscopic navigation system could increase the success rate for root canal treatments with recalcitrant lesion.

  8. Stereo Imaging Miniature Endoscope with Single Imaging Chip and Conjugated Multi-Bandpass Filters

    NASA Technical Reports Server (NTRS)

    Shahinian, Hrayr Karnig (Inventor); Bae, Youngsam (Inventor); White, Victor E. (Inventor); Shcheglov, Kirill V. (Inventor); Manohara, Harish M. (Inventor); Kowalczyk, Robert S. (Inventor)

    2018-01-01

    A dual objective endoscope for insertion into a cavity of a body for providing a stereoscopic image of a region of interest inside of the body including an imaging device at the distal end for obtaining optical images of the region of interest (ROI), and processing the optical images for forming video signals for wired and/or wireless transmission and display of 3D images on a rendering device. The imaging device includes a focal plane detector array (FPA) for obtaining the optical images of the ROI, and processing circuits behind the FPA. The processing circuits convert the optical images into the video signals. The imaging device includes right and left pupil for receiving a right and left images through a right and left conjugated multi-band pass filters. Illuminators illuminate the ROI through a multi-band pass filter having three right and three left pass bands that are matched to the right and left conjugated multi-band pass filters. A full color image is collected after three or six sequential illuminations with the red, green and blue lights.

  9. Endoscopic gastric reduction with an endoluminal suturing device: a multicenter prospective trial with 1-year follow-up.

    PubMed

    Huberty, Vincent; Machytka, Evzen; Boškoski, Ivo; Barea, Marie; Costamagna, Guido; Deviere, Jacques

    2018-06-15

     Obesity is the pandemic disease of this century. Surgery is the only effective treatment but cannot be offered to every patient. Endoscopic sutured gastroplasty is a minimally invasive technique that may potentially fill the gap between surgery and behavioral therapy. In this study, we prospectively investigated the efficacy and safety of a novel suturing device.  After a pre-bariatric multidisciplinary work-up, class 1 and 2 obese patients were included. Using a simple triangulation platform, transmural sutures with serosa-to-serosa apposition were performed in the gastric cavity. Patients were followed according to the same routines as those performed for bariatric procedures.  Between November 2015 and December 2016, 51 patients were included across three European Centers. Mean body mass index at baseline was 35.1 kg/m 2 (SD 3.0). Excess weight loss and total body weight loss at 1 year were 29 % (SD 28) and 7.4 % (SD 7), respectively, for the whole cohort (45 patients). At follow-up gastroscopy, 88 % of sutures were still in place (30 patients). No severe adverse events were observed.  Endoscopic sutured gastroplasty using this novel device is safe and achieved weight loss results in line with criteria expected for these endoluminal techniques. Further prospective studies vs. placebo or nutritional support are needed. © Georg Thieme Verlag KG Stuttgart · New York.

  10. Endoscopic device for functional imaging of the retina

    NASA Astrophysics Data System (ADS)

    Barriga, Simon; Lohani, Sweyta; Martell, Bret; Soliz, Peter; Ts'o, Dan

    2011-03-01

    Non-invasive imaging of retinal function based on the recording of spatially distributed reflectance changes evoked by visual stimuli has to-date been performed primarily using modified commercial fundus cameras. We have constructed a prototype retinal functional imager, using a commercial endoscope (Storz) for the frontend optics, and a low-cost back-end that includes the needed dichroic beam splitter to separate the stimulus path from the imaging path. This device has been tested to demonstrate its performance for the delivery of adequate near infrared (NIR) illumination, intensity of the visual stimulus and reflectance return in the imaging path. The current device was found to be capable of imaging reflectance changes of 0.1%, similar to that observable using the modified commercial fundus camera approach. The visual stimulus (a 505nm spot of 0.5secs) was used with an interrogation illumination of 780nm, and a sequence of imaged captured. At each pixel, the imaged signal was subtracted and normalized by the baseline reflectance, so that the measurement was ΔR/R. The typical retinal activity signal observed had a ΔR/R of 0.3-1.0%. The noise levels were measured when no stimulus was applied and found to vary between +/- 0.05%. Functional imaging has been suggested as a means to provide objective information on retina function that may be a preclinical indicator of ocular diseases, such as age-related macular degeneration (AMD), glaucoma, and diabetic retinopathy. The endoscopic approach promises to yield a significantly more economical retinal functional imaging device that would be clinically important.

  11. Safety and feasibility of an endoluminal-suturing device for endoscopic gastric reduction (with video).

    PubMed

    Huberty, Vincent; Ibrahim, Mostafa; Hiernaux, Martin; Chau, Alexandre; Dugardeyn, Sonia; Devière, Jacques

    2017-04-01

    Obesity is a major pandemic disease. Surgical therapy is highly effective, but its availability will likely be overwhelmed by the burden of the disease. Endoscopic technologies that could reproduce some of the clinical effects of surgery may become part of the treatment armamentarium. A simple transoral restrictive procedure could play a role in first-line surgical management. We evaluated the safety and feasibility of transmural suturing using a simple triangulation platform for gastric volume reduction through the creation of multiple double plicatures. Between May and July 2015, 11 obese (body mass index 34.6 ± 2.1 kg/m 2 ) patients (mean age, 36 ± 10 years) underwent gastroplasty through transmural endoscopic sutures (performed using a triangulation platform and an endoscopic stitcher). The median duration of the procedure was 2.00 hours (range, 1.15-3.15 hours) and dramatically decreased after the first 5 cases. No severe adverse events were observed. Mean (standard deviation) weight loss and percentage of excess weight loss were 5.8 kg (2.7%) and 21% (9%) at 1 month (n = 11), 8.8 kg (4.9%) and 33% (22%) at 3 months (n = 10), and 10.9 kg (7.3%) and 41% (33%) at 6 months (n = 10). Transoral endoscopic gastroplasty performed using a simple triangulation platform and a dedicated suturing device appears to be safe and effective at mid-term follow-up in creating gastric restriction and inducing weight loss in this first-in-humans experience. (Clinical trials registration number: NCT02534662.). Copyright © 2017 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  12. Development of a Haptic Interface for Natural Orifice Translumenal Endoscopic Surgery Simulation

    PubMed Central

    Dargar, Saurabh; Sankaranarayanan, Ganesh

    2016-01-01

    Natural orifice translumenal endoscopic surgery (NOTES) is a minimally invasive procedure, which utilizes the body’s natural orifices to gain access to the peritoneal cavity. The NOTES procedure is designed to minimize external scarring and patient trauma, however flexible endoscopy based pure NOTES procedures require critical scope handling skills. The delicate nature of the NOTES procedure requires extensive training, thus to improve access to training while reducing risk to patients we have designed and developed the VTEST©, a virtual reality NOTES simulator. As part of the simulator, a novel decoupled 2-DOF haptic device was developed to provide realistic force feedback to the user in training. A series of experiments were performed to determine the behavioral characteristics of the device. The device was found capable of rendering up to 5.62N and 0.190Nm of continuous force and torque in the translational and rotational DOF, respectively. The device possesses 18.1Hz and 5.7Hz of force bandwidth in the translational and rotational DOF, respectively. A feedforward friction compensator was also successfully implemented to minimize the negative impact of friction during the interaction with the device. In this work we have presented the detailed development and evaluation of the haptic device for the VTEST©. PMID:27008674

  13. Endoscopic low coherence interferometry in upper airways

    NASA Astrophysics Data System (ADS)

    Delacrétaz, Yves; Boss, Daniel; Lang, Florian; Depeursinge, Christian

    2009-07-01

    We introduce Endoscopic Low Coherence Interferometry to obtain topology of upper airways through commonly used rigid endoscopes. Quantitative dimensioning of upper airways pathologies is crucial to provide maximum health recovery chances, for example in order to choose the correct stent to treat endoluminal obstructing pathologies. Our device is fully compatible with procedures used in day-to-day examinations and can potentially be brought to bedside. Besides this, the approach described here can be almost straightforwardly adapted to other endoscopy-related field of interest, such as gastroscopy and arthroscopy. The principle of the method is first exposed, then filtering procedure used to extract the depth information is described. Finally, demonstration of the method ability to operate on biological samples is assessed through measurements on ex-vivo pork bronchi.

  14. Endoscopic stent suture fixation for prevention of esophageal stent migration during prolonged dilatation for achalasia treatment.

    PubMed

    Rieder, E; Asari, R; Paireder, M; Lenglinger, J; Schoppmann, S F

    2017-04-01

    The aim of this study is to compare endoscopic stent suture fixation with endoscopic clip attachment or the use of partially covered stents (PCS) regarding their capability to prevent stent migration during prolonged dilatation in achalasia. Large-diameter self-expanding metal stents (30 mm × 80 mm) were placed across the gastroesophageal junction in 11 patients with achalasia. Stent removal was scheduled after 4 to 7 days. To prevent stent dislocation, endoscopic clip attachment, endoscopic stent suture fixation, or PCS were used. The Eckardt score was evaluated before and 6 months after prolonged dilatation. After endoscopic stent suture fixation, no (0/4) sutured stent migrated. When endoscopic clips were used, 80% (4/5) clipped stents migrated (p = 0.02). Of two PCS (n = 2), one migrated and one became embedded leading to difficult stent removal. Technical adverse events were not seen in endoscopic stent suture fixation but were significantly correlated with the use of clips or PCS (r = 0.828, p = 0.02). Overall, 72% of patients were in remission regarding their achalasia symptoms 6 months after prolonged dilatation. Endoscopic suture fixation of esophageal stents but not clip attachment appears to be the best method of preventing early migration of esophageal stents placed at difficult locations such as at the naive gastroesophageal junction. © The Authors 2017. Published by Oxford University Press on behalf of International Society for Diseases of the Esophagus. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  15. Evaluation of a novel multi-articulated endoscope: proof of concept through a virtual simulation.

    PubMed

    Karvonen, Tuukka; Muranishi, Yusuke; Yamamoto, Goshiro; Kuroda, Tomohiro; Sato, Toshihiko

    2017-07-01

    In endoscopic surgery such as video-assisted thoracoscopic surgery and laparoscopic surgery, providing the surgeon a good view of the target is important. Rigid endoscope has for years been the go-to tool for this purpose, but it has certain limitations like the inability to work around obstacles. To improve on current tools, a novel multi-articulated endoscope (MAE) is currently under development. To investigate its feasibility and possible value, we performed a user test using virtual prototype of the MAE with the intent to show that it outperforms the conventional endoscope while bringing minimal additional burden to the operator. To evaluate the prototype, we built a virtual model of the MAE and a rigid oblique-viewing endoscope. Through a comparative user study we evaluate the ability of each device to visualize certain targets placed inside the virtual chest cavity by the angle between the visual axis of the scope and the normal of the plane of the target, while accounting for the usability of each endoscope by recording the time taken for each task. In addition, we collected a questionnaire from each participant to obtain feedback. The angles obtained using the MAE were smaller on average ([Formula: see text]), indicating that better visualization can be achieved through the proposed method. A nonsignificant difference in mean time taken for each task in favor of the rigid endoscope was also found ([Formula: see text]). We have demonstrated that better visualization for endoscopic surgery can be achieved through our novel MAE. The scope may bring about a paradigm shift in the field of minimally invasive surgery by providing more freedom in viewpoint selection, enabling surgeons to perform more elaborate procedures in minimally invasive settings.

  16. Magnetically-driven medical robots: An analytical magnetic model for endoscopic capsules design

    NASA Astrophysics Data System (ADS)

    Li, Jing; Barjuei, Erfan Shojaei; Ciuti, Gastone; Hao, Yang; Zhang, Peisen; Menciassi, Arianna; Huang, Qiang; Dario, Paolo

    2018-04-01

    Magnetic-based approaches are highly promising to provide innovative solutions for the design of medical devices for diagnostic and therapeutic procedures, such as in the endoluminal districts. Due to the intrinsic magnetic properties (no current needed) and the high strength-to-size ratio compared with electromagnetic solutions, permanent magnets are usually embedded in medical devices. In this paper, a set of analytical formulas have been derived to model the magnetic forces and torques which are exerted by an arbitrary external magnetic field on a permanent magnetic source embedded in a medical robot. In particular, the authors modelled cylindrical permanent magnets as general solution often used and embedded in magnetically-driven medical devices. The analytical model can be applied to axially and diametrically magnetized, solid and annular cylindrical permanent magnets in the absence of the severe calculation complexity. Using a cylindrical permanent magnet as a selected solution, the model has been applied to a robotic endoscopic capsule as a pilot study in the design of magnetically-driven robots.

  17. 21 CFR 884.4100 - Endoscopic electrocautery and accessories.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... coagulate fallopian tube tissue with a probe heated by low-voltage energy. This generic type of device may include the following accessories: electrical generators, probes, and electrical cables. (b...

  18. 21 CFR 884.4100 - Endoscopic electrocautery and accessories.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... coagulate fallopian tube tissue with a probe heated by low-voltage energy. This generic type of device may include the following accessories: electrical generators, probes, and electrical cables. (b...

  19. 21 CFR 884.4100 - Endoscopic electrocautery and accessories.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... coagulate fallopian tube tissue with a probe heated by low-voltage energy. This generic type of device may include the following accessories: electrical generators, probes, and electrical cables. (b...

  20. 21 CFR 884.4100 - Endoscopic electrocautery and accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... coagulate fallopian tube tissue with a probe heated by low-voltage energy. This generic type of device may include the following accessories: electrical generators, probes, and electrical cables. (b...

  1. Treatment Using the SpyGlass Digital System in a Patient with Hepatolithiasis after a Whipple Procedure.

    PubMed

    Harima, Hirofumi; Hamabe, Kouichi; Hisano, Fusako; Matsuzaki, Yuko; Itoh, Tadahiko; Sanuki, Kazutoshi; Sakaida, Isao

    2018-05-23

    An 89-year-old man was referred to our hospital for treatment of hepatolithiasis causing recurrent cholangitis. He had undergone a prior Whipple procedure. Computed tomography demonstrated left-sided hepatolithiasis. First, we conducted peroral direct cholangioscopy (PDCS) using an ultraslim endoscope. Although PDCS was successfully conducted, it was unsuccessful in removing all the stones. The stones located in the B2 segment were difficult to remove because the endoscope could not be inserted deeply into this segment due to the small size of the intrahepatic bile duct. Next, we substituted the endoscope with an upper gastrointestinal endoscope. After positioning the endoscope, the SpyGlass digital system (SPY-DS) was successfully inserted deep into the B2 segment. Upon visualizing the residual stones, we conducted SPY-DS-guided electrohydraulic lithotripsy. The stones were disintegrated and completely removed. In cases of PDCS failure, a treatment strategy using the SPY-DS can be considered for patients with hepatolithiasis after a Whipple procedure.

  2. A pilot study on using chlorine dioxide gas for disinfection of gastrointestinal endoscopes* #

    PubMed Central

    Yi, Ying; Hao, Li-mei; Ma, Shu-ren; Wu, Jin-hui; Wang, Tao; Lin, Song; Zhang, Zong-xing; Qi, Jian-cheng

    2016-01-01

    Objectives: This pilot study of employing chlorine dioxide (CD) gas to disinfect gastrointestinal endoscopes was conducted to meet the expectations of many endoscopy units in China for a high-efficiency and low-cost disinfectant. Methods: An experimental prototype with an active circulation mode was designed to use CD gas to disinfect gastrointestinal endoscopes. One type of testing device composed of polytetrafluoroethylene (PTFE) tubes (2 m long, inner diameter 1 mm) and bacterial carrier containers was used to simulate the channel of the endoscope. PTFE bacterial carriers inoculated with Bacillus atrophaeus with or without organic burden were used to evaluate the sporicidal activity of CD gas. Factors including exposure dosage, relative humidity (RH), and flow rate (FR) influencing the disinfection effect of CD gas were investigated. Moreover, an autoptic disinfecting test on eight real gastrointestinal endoscopes after clinical use was performed using the experimental prototype. Results: RH, exposure dosage, organic burden, and the FR through the channel significantly (P<0.05) affected the disinfection efficacy of CD gas for a long and narrow lumen. The log reduction increased as FR decreased. Treatment with 4 mg/L CD gas for 30 min at 0.8 L/min FR and 75% RH, resulted in complete inactivation of spores. Furthermore, all eight endoscopes with a maximum colony-forming unit of 915 were completely disinfected. The cost was only 3 CNY (0.46 USD) for each endoscope. Conclusions: The methods and results reported in this study could provide a basis for further studies on using CD gas for the disinfection of endoscopes. PMID:27381729

  3. Flexible Vesiculovasoscopy Using a Microoptical System in a Human Cadaver Model: An Experimental Approach for Atraumatic Endoscopy of the Seminal Tract.

    PubMed

    Schlager, Daniel; Maas, Moritz; Hein, Simon; Adams, Fabian; Schoenthaler, Martin; Wetterauer, Ulrich; Diemer, Thorsten; Weidner, Wolfgang; Miernik, Arkadiusz

    2016-08-01

    The most common pathologies of the seminal tract are persistent hematospermia, seminal vesicle stones, and seminal duct obstruction. Endoscopic diagnostic work-up of the seminal tract is impeded by complex anatomy and lack of technical equipment. To date, there is no standardized endoscopic approach. The purpose of this study was to investigate the applicability and feasibility of a flexible microoptical device for atraumatic endoscopy of the seminal tract in a male human cadaver. The transurethral endoscopic examination was performed on a male cadaver. No premortal interventions or diseases of the genitourinary tract had been reported. The seminal orifice was identified via cystoscopy and accessed by the Seldinger technique using a hydrophilic guidewire and ureteral catheter. Retrograde endoscopic inspection of the distal seminal tract was performed using a miniaturized flexible endoscope. An antegrade endoscopic inspection of the seminal tract was carried out via high scrotal access to the vas deferens. Structures of the seminal tract, such as the ejaculatory duct, seminal vesicles, and distal portion of the ductus deferentes, were visualized using the miniaturized endoscope. Image quality allowed identification of anatomical structures and characterization of tissue properties. The technical limitations we observed involved the system's maneuverability. Initial results of this novel endoscopic approach to the seminal tract using a flexible microoptical system are encouraging. However, considerable anatomical limitations of the targeted organs necessitate further refinements of the technical equipment. This approach might improve diagnostics and treatment of genitourinary diseases. Future surgical techniques may include intraseminal laser therapy or endoocclusion to monitor fertility in men.

  4. Optic for an endoscope/borescope having high resolution and narrow field of view

    DOEpatents

    Stone, Gary F.; Trebes, James E.

    2003-10-28

    An optic having optimized high spatial resolution, minimal nonlinear magnification distortion while at the same time having a limited chromatic focal shift or chromatic aberrations. The optic located at the distal end of an endoscopic inspection tool permits a high resolution, narrow field of view image for medical diagnostic applications, compared to conventional optics for endoscopic instruments which provide a wide field of view, low resolution image. The image coverage is over a narrow (<20 degrees) field of view with very low optical distortion (<5% pin cushion or barrel distortion. The optic is also optimized for best color correction as well as to aid medical diagnostics.

  5. Biopsy using a magnetic capsule endoscope carrying, releasing, and retrieving untethered microgrippers.

    PubMed

    Yim, Sehyuk; Gultepe, Evin; Gracias, David H; Sitti, Metin

    2014-02-01

    This paper proposes a new wireless biopsy method where a magnetically actuated untethered soft capsule endoscope carries and releases a large number of thermo-sensitive, untethered microgrippers (μ-grippers) at a desired location inside the stomach and retrieves them after they self-fold and grab tissue samples. We describe the working principles and analytical models for the μ-gripper release and retrieval mechanisms, and evaluate the proposed biopsy method in ex vivo experiments. This hierarchical approach combining the advanced navigation skills of centimeter-scaled untethered magnetic capsule endoscopes with highly parallel, autonomous, submillimeter scale tissue sampling μ-grippers offers a multifunctional strategy for gastrointestinal capsule biopsy.

  6. Nonampullary duodenal adenoma: Current understanding of its diagnosis, pathogenesis, and clinical management

    PubMed Central

    Lim, Chul-Hyun; Cho, Young-Seok

    2016-01-01

    Nonampullary duodenal adenomas are relatively common in familial adenomatous polyposis (FAP), but nonampullary sporadic duodenal adenomas (SDAs) are rare. Emerging evidence shows that duodenal adenomas, regardless of their anatomic location and whether they are sporadic or FAP-related, share morphologic and molecular features with colorectal adenomas. The available data suggest that duodenal adenomas develop to duodenal adenocarcinomas via similar mechanisms. The optimal approach for management of duodenal adenomas remains to be determined. The techniques for endoscopic resection of duodenal adenoma include snare polypectomy, endoscopic mucosal resection (EMR), endoscopic submucosal dissection (ESD), and argon plasma coagulation ablation. EMR may facilitate removal of large duodenal polyps. Although several studies have reported cases of successful ESD for duodenal adenomas, the procedure is technically difficult to perform safely because of the anatomical properties of the duodenum. Although current clinical practice recommends endoscopic resection of all large duodenal adenomas in patients with FAP, endoscopic treatment is usually insufficient to guarantee a polyp-free duodenum. Surgery is indicated for FAP patients with severe polyposis or nonampullary SDAs or FAP-related polyps not amenable to endoscopic resection. Further studies are needed to develop newer endoscopic techniques to guide diagnostic and therapeutic decisions for future management of nonampullary duodenal adenomas. PMID:26811631

  7. Endoscopic management of gastrointestinal perforations, leaks and fistulas

    PubMed Central

    Rogalski, Pawel; Daniluk, Jaroslaw; Baniukiewicz, Andrzej; Wroblewski, Eugeniusz; Dabrowski, Andrzej

    2015-01-01

    Gastrointestinal perforations, leaks and fistulas may be serious and life-threatening. The increasing number of endoscopic procedures with a high risk of perforation and the increasing incidence of leakage associated with bariatric operations call for a minimally invasive treatment for these complications. The therapeutic approach can vary greatly depending on the size, location, and timing of gastrointestinal wall defect recognition. Some asymptomatic patients can be treated conservatively, while patients with septic symptoms or cardio-pulmonary insufficiency may require intensive care and urgent surgical treatment. However, most gastrointestinal wall defects can be satisfactorily treated by endoscopy. Although the initial endoscopic closure rates of chronic fistulas is very high, the long-term results of these treatments remain a clinical problem. The efficacy of endoscopic therapy depends on several factors and the best mode of treatment will depend on a precise localization of the site, the extent of the leak and the endoscopic appearance of the lesion. Many endoscopic tools for effective closure of gastrointestinal wall defects are currently available. In this review, we summarized the basic principles of the management of acute iatrogenic perforations, as well as of postoperative leaks and chronic fistulas of the gastrointestinal tract. We also described the effectiveness of various endoscopic methods based on current research and our experience. PMID:26457014

  8. 21 CFR 884.4150 - Bipolar endoscopic coagulator-cutter and accessories.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... high frequency electrical current through tissue between two electrical contacts of a probe. This generic type of device may include the following accessories: an electrical generator, probes, and...

  9. 21 CFR 884.4150 - Bipolar endoscopic coagulator-cutter and accessories.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... high frequency electrical current through tissue between two electrical contacts of a probe. This generic type of device may include the following accessories: an electrical generator, probes, and...

  10. 21 CFR 884.4150 - Bipolar endoscopic coagulator-cutter and accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... high frequency electrical current through tissue between two electrical contacts of a probe. This generic type of device may include the following accessories: an electrical generator, probes, and...

  11. 21 CFR 884.4150 - Bipolar endoscopic coagulator-cutter and accessories.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... high frequency electrical current through tissue between two electrical contacts of a probe. This generic type of device may include the following accessories: an electrical generator, probes, and...

  12. Lower Learning Difficulty and Fluoroscopy Reduction of Transforaminal Percutaneous Endoscopic Lumbar Discectomy with an Accurate Preoperative Location Method.

    PubMed

    Fan, Guoxin; Gu, Xin; Liu, Yifan; Wu, Xinbo; Zhang, Hailong; Gu, Guangfei; Guan, Xiaofei; He, Shisheng

    2016-01-01

    Transforaminal percutaneous endoscopic lumbar discectomy (tPELD) poses great challenges for junior surgeons. Beginners often require repeated attempts using fluoroscopy causing more punctures, which may significantly undermine their confidence and increase the radiation exposure to medical staff and patients. Moreover, the impact of an accurate location on the learning curve of tPELD has not been defined. The study aimed to investigate the impact of an accurate preoperative location method on learning difficulty and fluoroscopy time of tPELD. Retrospective evaluation. Patients receiving tPELD by one surgeon with a novel accurate preoperative location method were regarded as Group A, and those receiving tPELD by another surgeon with a conventional fluoroscopy method were regarded as Group B. From January 2012 to August 2014, we retrospectively reviewed the first 80 tPELD cases conducted by 2 junior surgeons. The operation time, fluoroscopy times, preoperative location time, and puncture-channel time were thoroughly analyzed. The operation time of the first 20 patients were 99.75 ± 10.38 minutes in Group A and 115.7 ± 16.46 minutes in Group B, while the operation time of all 80 patients was 88.36 ± 11.56 minutes in Group A and 98.26 ± 14.90 minutes in Group B. Significant differences were detected in operation time between the 2 groups, both for the first 20 patients and total 80 patients (P < 0.05). The fluoroscopy times were 26.78 ± 4.17 in Group A and 33.98 ± 2.69 in Group B (P < 0.001). The preoperative location time was 3.43 ± 0.61 minutes in Group A and 5.59 ± 1.46 minutes in Group B (P < 0.001). The puncture-channel time was 27.20 ± 4.49 minutes in Group A and 34.64 ± 8.35 minutes in Group B (P < 0.001). There was a moderate correlation between preoperative location time and puncture-channel time (r = 0.408, P < 0.001), and a moderate correlation between preoperative location time and fluoroscopy times (r = 0.441, P < 0.001). Mild correlations were also observed between preoperative location time and operation time (r = 0.270, P = 0.001). There were no significant differences in preoperative back visual analogue scale (VAS) score, postoperative back VAS, preoperative leg VAS, postoperative leg VAS, preoperative Japanese Orthopaedic Association (JOA) score, postoperative JOA, preoperative Oswestry disability score (ODI), or postoperative ODI (P > 0.05). However, significant differences were all detected between preoperative abovementioned scores and postoperative scores (P < 0.05). Moreover, there was no significant differences in Macnab satisfaction between the 2 groups (P = 0.179). There were 2 patients with recurrence in Group A and 3 patients in Group B. Twelve patients with postoperative disc remnants were identified in Group A and 9 patients in Group B. No significant difference was identified between the 2 groups (P = 0.718). The preoperative lumbar location method is just a tiny step in tPELD, junior surgeons still need to focus on their subjective feelings during punctures and accumulating their experience in endoscopic discectomy. The accurate preoperative location method lowered the learning difficulty and reduced the fluoroscopy time of tPELD, which was also associated with lower preoperative location time and puncture-channel time. Key words: Learning difficulty, fluoroscopy reduction, transforamimal percutaneous endoscopic lumbar discectomy, preoperative locationLearning difficulty, fluoroscopy reduction, transforamimal percutaneous endoscopic lumbar discectomy, preoperative location.

  13. A Clinical Wide-Field Fluorescence Endoscopic Device for Molecular Imaging Demonstrating Cathepsin Protease Activity in Colon Cancer.

    PubMed

    Sensarn, Steven; Zavaleta, Cristina L; Segal, Ehud; Rogalla, Stephan; Lee, Wansik; Gambhir, Sanjiv S; Bogyo, Matthew; Contag, Christopher H

    2016-12-01

    Early and effective detection of cancers of the gastrointestinal tract will require novel molecular probes and advances in instrumentation that can reveal functional changes in dysplastic and malignant tissues. Here, we describe adaptation of a wide-field clinical fiberscope to perform wide-field fluorescence imaging while preserving its white-light capability for the purpose of providing wide-field fluorescence imaging capability to point-of-care microscopes. We developed and used a fluorescent fiberscope to detect signals from a quenched probe, BMV109, that becomes fluorescent when cleaved by, and covalently bound to, active cathepsin proteases. Cathepsins are expressed in inflammation- and tumor-associated macrophages as well as directly from tumor cells and are a promising target for cancer imaging. The fiberscope has a 1-mm outer diameter enabling validation via endoscopic exams in mice, and therefore we evaluated topically applied BMV109 for the ability to detect colon polyps in an azoxymethane-induced colon tumor model in mice. This wide-field endoscopic imaging device revealed consistent and clear fluorescence signals from BMV109 that specifically localized to the polypoid regions as opposed to the normal adjacent colon tissue (p < 0.004) in the murine colon carcinoma model. The sensitivity of detection of BMV109 with the fluorescence fiberscope suggested utility of these tools for early detection at hard-to-reach sites. The fiberscope was designed to be used in conjunction with miniature, endoscope-compatible fluorescence microscopes for dual wide-field and microscopic cancer detection.

  14. Determination of optimal ultrasound planes for the initialisation of image registration during endoscopic ultrasound-guided procedures.

    PubMed

    Bonmati, Ester; Hu, Yipeng; Gibson, Eli; Uribarri, Laura; Keane, Geri; Gurusami, Kurinchi; Davidson, Brian; Pereira, Stephen P; Clarkson, Matthew J; Barratt, Dean C

    2018-06-01

    Navigation of endoscopic ultrasound (EUS)-guided procedures of the upper gastrointestinal (GI) system can be technically challenging due to the small fields-of-view of ultrasound and optical devices, as well as the anatomical variability and limited number of orienting landmarks during navigation. Co-registration of an EUS device and a pre-procedure 3D image can enhance the ability to navigate. However, the fidelity of this contextual information depends on the accuracy of registration. The purpose of this study was to develop and test the feasibility of a simulation-based planning method for pre-selecting patient-specific EUS-visible anatomical landmark locations to maximise the accuracy and robustness of a feature-based multimodality registration method. A registration approach was adopted in which landmarks are registered to anatomical structures segmented from the pre-procedure volume. The predicted target registration errors (TREs) of EUS-CT registration were estimated using simulated visible anatomical landmarks and a Monte Carlo simulation of landmark localisation error. The optimal planes were selected based on the 90th percentile of TREs, which provide a robust and more accurate EUS-CT registration initialisation. The method was evaluated by comparing the accuracy and robustness of registrations initialised using optimised planes versus non-optimised planes using manually segmented CT images and simulated ([Formula: see text]) or retrospective clinical ([Formula: see text]) EUS landmarks. The results show a lower 90th percentile TRE when registration is initialised using the optimised planes compared with a non-optimised initialisation approach (p value [Formula: see text]). The proposed simulation-based method to find optimised EUS planes and landmarks for EUS-guided procedures may have the potential to improve registration accuracy. Further work will investigate applying the technique in a clinical setting.

  15. Endoscopic-assisted resection of a pedunculated uterine leiomyoma with maximal tissue preservation in a cow and a mare.

    PubMed

    Schneeweiss, Wilfried; Krump, Lea; Metcalfe, Lucy; Ryan, Eoin; Beltman, Marijke; Jahns, Hanne; David, Florent

    2015-02-01

    To report successful minimally invasive treatment of a uterine leiomyoma in a cow and a mare. Clinical report. Limousine cow (n = 1), Thoroughbred mare (n = 1). A 10-year-old cow and an 18-year-old mare were presented for difficulties in breeding and infertility, respectively. Examination of the reproductive tract revealed the presence of a large mass attached to the uterine wall via a wide and short peduncle in both cases. The mass expanded into the uterine lumen in the mare and into the abdomen in the cow. Both masses were removed using a minimally invasive endoscopic approach and a vessel-sealing and dividing device. Minimally invasive surgical resection of a subserosal and a submucosal leiomyoma with maximal sparing of uterine tissue resulted in a short convalescence period and apparent return to breeding function in a cow and a mare. Use of a vessel-sealing and dividing device provided excellent hemostasis and decreased tissue handling. Leiomyoma with short, wide, and thick peduncles were treated successfully in a cow and a mare with minimally invasive endoscopic approaches aiming at maximal uterine tissue preservation. © Copyright 2014 by The American College of Veterinary Surgeons.

  16. Development of terahertz endoscopic system for cancer detection

    NASA Astrophysics Data System (ADS)

    Doradla, Pallavi; Alavi, Karim; Joseph, Cecil S.; Giles, Robert H.

    2016-02-01

    Terahertz (THz) imaging is emerging as a robust platform for a myriad of applications in the fields of security, health, astronomy and material science. The terahertz regime with wavelengths spanning from microns to millimeters is a potentially safe and noninvasive medical imaging modality for detecting cancers. Endoscopic imaging systems provide high flexibility in examining the interior surfaces of an organ or tissue. Researchers have been working on the development of THz endoscopes with photoconductive antennas, which necessarily operate under high voltage, and require at least two channels to measure the reflected signal from the specimen. This manuscript provides the design and imperative steps involved in the development of a single-channel terahertz endoscopic system. The continuous-wave terahertz imaging system utilizes a single flexible terahertz waveguide channel to transmit and collect the back reflected intrinsic terahertz signal from the sample and is capable of operation in both transmission and reflection modalities. To determine the feasibility of using a terahertz endoscope for cancer detection, the co- and cross-polarized terahertz remittance from human colonic tissue specimens were collected at 584 GHz frequency. The two dimensional terahertz images obtained using polarization specific detection exhibited intrinsic contrast between cancerous and normal regions of fresh colorectal tissue. The level of contrast observed using endoscopic imaging correlates well with the contrast levels observed in the free space ex vivo terahertz reflectance studies of human colonic tissue. The prototype device developed in this study represents a significant step towards clinical endoscopic application of THz technology for in vivo colon cancer screening.

  17. [Current status of extracorporeal shock wave lithotripsy in urinary lithiasis.

    PubMed

    Pereira-Arias, Jose Gregorio; Gamarra-Quintanilla, Mikel; Urdaneta-Salegui, Luis Felipe; Mora-Christian, Jorge Alberto; Sánchez-Vazquez, Andrea; Astobieta-Odriozola, Ander; Ibarluzea-González, Gaspar

    2017-03-01

    Over the last decade, urinary lithiasis' prevalence has dramatically increased due to diet and lifestyle changes, growing 10.6% and 7.1% in men and women respectively. Extracorporeal shock wave lithotripsy has lost relevance in current practice due to endoscopic device development and unpredictability of results. Instrument miniaturization is leading to an increase of the percutaneous approach of increasingly smaller stones, while most flexible ureteroscopes durability and digitalization has allowed urologists to address larger stones. So that, decision algorithm is now impossible to define, but what is clear is that ESWL has declined worldwide. Can it disappear as a urinary lithiasis treatment modality? If we don't improve appropriate candidate selection and optimize disintegration efficiency, guidelines are going to replace the more "boring" ESWL by popular and more attractive endoscopes. Shock wave technology has evolved in the last two decades, however lithotripsy fundamental principle has not changed. ESWL has passed the test of time and centers dedicated to stone treatment should have a lithotripter in order to offer an appropriate balance in different options for different clinical situations. New developments will be focused on improvements in location (in-line navigation systems; Vision track system) and automatic ultrasound location on a robotic arm; monitoring and stone fixation, implementation of different focal sizes with new acoustic lenses, multitask working stations that allow endourological approach, coupling control (avoiding microbubbles) and low cost devices for different applications. On the other hand, optimizing outcomes by: slower pulse rates, ramping strategies and patient selection with soft stones, short stone-skin distance, low BMI and favorable collecting system anatomy, allow us to achieve better outcomes in shock wave treatments. SWL still represents a unique non invasive method of stone disease treatment with no anesthesia and low complication rates; and a high proportion of stones could still be treated with shock waves and remains among patient's first options. This update objective has been to review the evolution, identify shock wave new developments and clarify their impact on our daily practice in urinary stones treatment.

  18. Safety of capsule endoscopy using human body communication in patients with cardiac devices.

    PubMed

    Chung, Joo Won; Hwang, Hye Jin; Chung, Moon Jae; Park, Jeong Youp; Pak, Hui-Nam; Song, Si Young

    2012-06-01

    The MiroCam (IntroMedic, Ltd., Seoul, Korea) is a small-bowel capsule endoscope that uses human body communication to transmit data. The potential interactions between cardiac devices and the capsule endoscope are causes for concern, but no data are available for this matter. This clinical study was designed to evaluate the potential influence of the MiroCam capsules on cardiac devices. Patients with cardiac pacemakers or implantable cardiac defibrillators referred for evaluation of small bowel disease were prospectively enrolled in this study. Before capsule endoscopy, a cardiologist checked baseline electrocardiograms and functions of the cardiac devices. Cardiac rhythms were continuously monitored by 24-h telemetry during capsule endoscopy in the hospital. After completion of procedures, functions of the cardiac devices were checked again for interference. Images from the capsule endoscopy were reviewed and analyzed for technical problems. Six patients, three with pacemakers and three with implantable cardiac defibrillators, were included in the study. We identified no disturbances in the cardiac devices and no arrhythmias detected on telemetry monitoring during capsule endoscopy. No significant changes in the programmed parameters of the cardiac devices were noted after capsule endoscopy. There were no imaging disturbances from the cardiac devices on capsule endoscopy. Capsule endoscopy using human body communication to transmit data was safely performed in patients with cardiac pacemakers or implantable cardiac defibrillators. Images from the capsule endoscopy were not affected by cardiac devices. A further large-scale study is required to confirm the safety of capsule endoscopy with various types of cardiac devices.

  19. Clinical study using novel endoscopic system for measuring size of gastrointestinal lesion

    PubMed Central

    Oka, Kiyoshi; Seki, Takeshi; Akatsu, Tomohiro; Wakabayashi, Takao; Inui, Kazuo; Yoshino, Junji

    2014-01-01

    AIM: To verify the performance of a lesion size measurement system through a clinical study. METHODS: Our proposed system, which consists of a conventional endoscope, an optical device, an optical probe, and a personal computer, generates a grid scale to measure the lesion size from an endoscopic image. The width of the grid scale is constantly adjusted according to the distance between the tip of the endoscope and lesion because the lesion size on an endoscopic image changes according to the distance. The shape of the grid scale was corrected to match the distortion of the endoscopic image. The distance was calculated using the amount of laser light reflected from the lesion through an optical probe inserted into the instrument channel of the endoscope. The endoscopist can thus measure the lesion size without contact by comparing the lesion with the size of the grid scale on the endoscopic image. (1) A basic test was performed to verify the relationship between the measurement error eM and the tilt angle of the endoscope; and (2) The sizes of three colon polyps were measured using our system during endoscopy. These sizes were immediately measured by scale after their removal. RESULTS: There was no error at α = 0°. In addition, the values of eM (mean ± SD) were 0.24 ± 0.11 mm (α = 10°), 0.90 ± 0.58 mm (α = 20°) and 2.31 ± 1.41 mm (α = 30°). According to these results, our system has been confirmed to measure accurately when the tilt angle is less than 20°. The measurement error was approximately 1 mm in the clinical study. Therefore, it was concluded that our proposed measurement system was also effective in clinical examinations. CONCLUSION: By combining simple optical equipment with a conventional endoscope, a quick and accurate system for measuring lesion size was established. PMID:24744595

  20. Development of a virtual reality training system for endoscope-assisted submandibular gland removal.

    PubMed

    Miki, Takehiro; Iwai, Toshinori; Kotani, Kazunori; Dang, Jianwu; Sawada, Hideyuki; Miyake, Minoru

    2016-11-01

    Endoscope-assisted surgery has widely been adopted as a basic surgical procedure, with various training systems using virtual reality developed for this procedure. In the present study, a basic training system comprising virtual reality for the removal of submandibular glands under endoscope assistance was developed. The efficacy of the training system was verified in novice oral surgeons. A virtual reality training system was developed using existing haptic devices. Virtual reality models were constructed from computed tomography data to ensure anatomical accuracy. Novice oral surgeons were trained using the developed virtual reality training system. The developed virtual reality training system included models of the submandibular gland and surrounding connective tissues and blood vessels entering the submandibular gland. Cutting or abrasion of the connective tissue and manipulations, such as elevation of blood vessels, were reproduced by the virtual reality system. A training program using the developed system was devised. Novice oral surgeons were trained in accordance with the devised training program. Our virtual reality training system for endoscope-assisted removal of the submandibular gland is effective in the training of novice oral surgeons in endoscope-assisted surgery. Copyright © 2016 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  1. Weight loss endoscopy: Development, applications, and current status

    PubMed Central

    Kumar, Nitin

    2016-01-01

    Obesity and its comorbidities - including diabetes and obstructive sleep apnea - have taken a large and increasing toll on the United States and the rest of the world. The availability of commercial, clinical, and operative therapies for weight management have not been effective at a societal level. Endoscopic bariatric therapy is gaining acceptance as more effective than diet and lifestyle measures, and less invasive than bariatric surgery. Various endoscopic therapies are analogues of the restrictive or bypass components of bariatric surgery, utilizing gastric remodeling or intestinal anastomosis to achieve proven weight loss and metabolic benefits. Others, such as aspiration therapy, employ novel mechanisms of action. Intragastric balloons have recently been approved by the United States Food and Drug Administration, and a number of other technologies have completed large multicenter trials (such as AspireAssist aspiration therapy and Primary Obesity Surgery Endolumenal). Endoscopic sleeve gastroplasty and transoral outlet reduction for endoscopic revision of gastric bypass have proven safe and effective in a number of studies. As devices are approved for use, data will continue to accumulate for safety, effectiveness, and cost effectiveness. Bariatric endoscopists should be prepared to appropriately target and apply various endoscopic bariatric therapies in the context of a comprehensive long-term weight management program. PMID:27610017

  2. Past, present and future of Barrett's oesophagus.

    PubMed

    Tan, W K; di Pietro, M; Fitzgerald, R C

    2017-07-01

    Barrett's oesophagus is a condition which predisposes towards development of oesophageal adenocarcinoma, a highly lethal tumour which has been increasing in incidence in the Western world over the past three decades. There have been tremendous advances in the field of Barrett's oesophagus, not only in diagnostic modalities, but also in therapeutic strategies available to treat this premalignant disease. In this review, we discuss the past, present and future of Barrett's oesophagus. We describe the historical and new evolving diagnostic criteria of Barrett's oesophagus, while also comparing and contrasting the British Society of Gastroenterology guidelines, American College of Gastroenterology guidelines and International Benign Barrett's and CAncer Taskforce (BOBCAT) for Barrett's oesophagus. Advances in endoscopic modalities such as confocal and volumetric laser endomicroscopy, and a non-endoscopic sampling device, the Cytosponge, are described which could aid in identification of Barrett's oesophagus. With regards to therapy we review the evidence for the utility of endoscopic mucosal resection and radiofrequency ablation when coupled with better characterization of dysplasia. These endoscopic advances have transformed the management of Barrett's oesophagus from a primarily surgical disease into an endoscopically managed condition. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  3. Experience in colon sparing surgery in North America: advanced endoscopic approaches for complex colorectal lesions.

    PubMed

    Gorgun, Emre; Benlice, Cigdem; Abbas, Maher A; Steele, Scott

    2018-07-01

    Need for colon sparing interventions for premalignant lesions not amenable to conventional endoscopic excision has stimulated interest in advanced endoscopic approaches. The aim of this study was to report a single institution's experience with these techniques. A retrospective review was conducted of a prospectively collected database of all patients referred between 2011 and 2015 for colorectal resection of benign appearing deemed endoscopically unresectable by conventional endoscopic techniques. Patients were counseled for endoscopic submucosal dissection (ESD) with possible combined endoscopic-laparoscopic surgery (CELS) or alternatively colorectal resection if unable to resect endoscopically or suspicion for cancer. Lesion characteristic, resection rate, complications, and outcomes were evaluated. 110 patients were analyzed [mean age 64 years, female gender 55 (50%), median body mass index 29.4 kg/m 2 ]. Indications for interventions were large polyp median endoscopic size 3 cm (range 1.5-6.5) and/or difficult location [cecum (34.9%), ascending colon (22.7%), transverse colon (14.5%), hepatic flexure (11.8%), descending colon (6.3%), sigmoid colon (3.6%), rectum (3.6%), and splenic flexure (2.6%)]. Lesion morphology was sessile (N = 98, 93%) and pedunculated (N = 12, 7%). Successful endoscopic resection rate was 88.2% (N = 97): ESD in 69 patients and CELS in 28 patients. Complication rate was 11.8% (13/110) [delayed bleeding (N = 4), perforation (N = 3), organ-space surgical site infection (SSI) (N = 2), superficial SSI (N = 1), and postoperative ileus (N = 3)]. Out of 110 patients, 13 patients (11.8%) required colectomy for technical failure (7 patients) or carcinoma (6 patients). During a median follow-up of 16 months (range 6-41 months), 2 patients had adenoma recurrence. Advanced endoscopic surgery appears to be a safe and effective alternative to colectomy for patients with complex premalignant lesions deemed unresectable with conventional endoscopic techniques.

  4. One-step endosonography-guided drainage of a pancreatic pseudocyst: a new technique of stent delivery through the echo endoscope.

    PubMed

    Vilmann, P; Hancke, S; Pless, T; Schell-Hincke, J D; Henriksen, F W

    1998-10-01

    We report here the first case of a one-step endosonography(EUS)-guided pseudocyst drainage. A prototype large channel curved array echo endoscope (Pentax FG-38 UX) and a prototype delivery system for placement of an endoprosthesis was used for the procedure. The delivery system (GIP MedicinTechnik GmbH/Medi-Globe Corporation) consists of a handle part with a piston, a metal ring sheath, a plastic catheter with a diathermy needle and a double pigtail endoprosthesis (8.5 Fr). When mounted on the endoscope the endoprosthesis can be advanced out of the distal end of the endoscope. The introduction of the stent as well as the stent release can be monitored entirely by ultrasound. The procedure was tested in a 76-year-old woman with a pseudocyst measuring 60 mm in diameter located in the tail of the pancreas. The procedure was well tolerated by the patient, and there were no procedural complications. The advantage of a large channel echo endoscope and our new prototype delivery system is that the endoprosthesis can be inserted in to a pancreatic cyst guided exclusively by EUS without exchange of endoscopes, catheters or guide wires. Further studies are warranted.

  5. Endoscopic ultrasound guided drainage of pancreatic fluid collections: Assessment of the procedure, technical details and review of the literature

    PubMed Central

    Puri, Rajesh; Thandassery, Ragesh Babu; Alfadda, Abdulrahman A; Kaabi, Saad Al

    2015-01-01

    Endoscopic ultrasound (EUS) guided drainage of pancreatic fluid collections (PFC) has become increasingly popular and become first line management option in many centers. Use of therapeutic echoendoscopes has greatly increased the applicability of EUS guided transmural drainage. Drainage is indicated in symptomatic PFCs, PFC related infection, bleed, luminal obstruction, fistulization and biliary obstruction. EUS guided transmural drainage of PFCs is preferred in patients with non bulging lesions, portal hypertension, bleeding tendency and in those whom conventional drainage has failed. In the present decade significant progress has been made in minimally invasive endoscopic techniques. There are newer stent designs, access devices and techniques for more efficient drainage of PFCs. In this review, we discuss the EUS guided drainage of PFCs in acute pancreatitis. PMID:25901214

  6. Laparoscopic-assisted percutaneous endoscopic gastrostomy: insertion of a skin-level device using a tear-away sheath

    PubMed Central

    Livingston, Michael H.; Pepe, Daniel; Jones, Sarah; Bütter, Andreana; Merritt, Neil H.

    2015-01-01

    Background This study describes our experience with the placement of a skin-level gastrostomy device (MIC-KEY) in a single procedure. Methods We identified infants, children and young adults who underwent laparoscopic-assisted percutaneous endoscopic gastrostomy (LAPEG) tube insertion between October 2009 and June 2013. The steps of this procedure include upper endoscopy, single-port laparoscopy, gastropexy via percutaneous T-fasteners and placement of a skin-level gastrostomy device (MIC-KEY) using a “push” technique with a tear-away sheath. Results We included 92 patients in our study. Mean age was 3.7 years (range 3 wk–5 yr), and mean weight was 11.2 (range 2.8–54) kg. Median procedural time was 20 (range 12–76) minutes. Total median duration for the most recent 25 procedures was lower than that of the first 25 (62 v. 79 min, p = 0.004). There were no intraoperative complications or conversions to open surgery. Postoperative complications were observed in 6 (6.5%) patients. Three retained T-fasteners were assessed endoscopically (n = 1) or removed via local excision (n = 2). Two patients experienced early dislodged feeding tubes that were replaced via interventional radiology (n = 1) or repeat LAPEG (n = 1). There was also 1 intra-abdominal fluid collection that was drained percutaneously but ultimately required a laparotomy and washout. There were no major complications in the most recent 50 procedures. Conclusion Our results suggest that LAPEG is a safe, minimally invasive procedure for infants, children and young adults. This approach allows for immediate use of a skin-level gastrostomy device without the need for postoperative tube exchanges. PMID:26204365

  7. Design of a modified endoscope illuminator for spectral imaging of colorectal tissues

    NASA Astrophysics Data System (ADS)

    Browning, Craig M.; Mayes, Samuel; Rich, Thomas C.; Leavesley, Silas J.

    2017-02-01

    The gold standard for locating colonic polyps is a white light endoscope in a colonoscopy, however, polyps smaller than 5 mm can be easily missed. Modified procedures such as narrow band imaging have shown only marginal increases in detection rates. Spectral imaging is a potential solution to improve the sensitivity and specificity of colonoscopies by providing the ability to distinguish molecular fluorescence differences in tissues. The goal of this work is to implement a spectral endoscopic light source to acquire spectral image data of colorectal tissues. A beta-version endoscope light source was developed, by retrofitting a white light endoscope light source (Olympus, CLK-4) with 16 narrow band LEDs. This redesigned, beta-prototype uses high-power LEDs with a minimum output of 500 mW to provide sufficient spectral output (0.5 mW) through the endoscope. A mounting apparatus was designed to provide sufficient heat dissipation. Here, we report recent results of our tests to characterize the intensity output through the light source and endoscope to determine the flat spectral output for imaging and intensity losses through the endoscope. We also report preliminary spectral imaging data from transverse pig colon that demonstrates the ability to result in working practical spectral data. Preliminary results of this revised prototype spectral endoscope system demonstrate that there is sufficient power to allow the imaging process to continue and potentially determine spectral differences in cancerous and normal tissue from imaging ex vivo pairs. Future work will focus on building a spectral library for the colorectal region and refining the user interface the system for in vivo use.

  8. 21 CFR 884.1660 - Transcervical endoscope (amnioscope) and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... visualize the fetus or amniotic fluid and to sample fetal blood or amniotic fluid. This generic type of device may include obturators, instruments used through an operating channel, light sources and cables...

  9. Electrocautery device does not provide adequate pulmonary vessel sealing in transumbilical anatomic pulmonary lobectomy.

    PubMed

    Liu, Hung-Ping; Chu, Yen; Wu, Yi-Cheng; Hsieh, Ming-Ju; Liu, Chieng-Ying; Chen, Tzu-Ping; Chao, Yin-Kai; Wu, Ching-Yang; Yeh, Chi-Ju; Ko, Po-Jen; Liu, Yun-Hen

    2016-05-01

    Safe pulmonary vessel sealing device plays a crucial role in anatomic lung resection. In 2014, we reported high rates of massive bleeding complications during transumbilical lobectomy in a canine model due to difficulty in managing the pulmonary vessel with an endostapler. In this animal survival series, we aimed to evaluate the outcome of pulmonary vessel sealing with an electrocautery device to simplify the transumbilical thoracic surgery. Under general anesthesia, a 3-cm longitudinal incision was made over the umbilicus. Under video guidance, a bronchoscope was inserted through the incision for exploration. The diaphragmatic wound was created with an electrocautery knife and used as the entrance into the thoracic cavity. Using the transumbilical technique, anatomic lobectomy was performed with electrosurgical devices and endoscopic vascular staplers in 15 canines. Transumbilical endoscopic anatomic lobectomy was successfully completed in 12 of the 15 animals. Intraoperative bleeding developed in three animals during pulmonary hilum dissection, where one animal was killed due to hemodynamic instability and the other two animals required thoracotomy to complete the operation. There were five delayed bleeding and surgical mortality cases caused by inadequate vessel sealing by electrosurgical devices. Postmortem examination confirmed correct transumbilical lobectomy in the twelve animals that survived the operations. Transumbilical anatomic lobectomy is technically feasible in a canine model; however, the electrosurgical devices were not effective in sealing the pulmonary vessel in the current canine model.

  10. Microarthroscopy System With Image Processing Technology Developed for Minimally Invasive Surgery

    NASA Technical Reports Server (NTRS)

    Steele, Gynelle C.

    2001-01-01

    In a joint effort, NASA, Micro Medical Devices, and the Cleveland Clinic have developed a microarthroscopy system with digital image processing. This system consists of a disposable endoscope the size of a needle that is aimed at expanding the use of minimally invasive surgery on the knee, ankle, and other small joints. This device not only allows surgeons to make smaller incisions (by improving the clarity and brightness of images), but it gives them a better view of the injured area to make more accurate diagnoses. Because of its small size, the endoscope helps reduce physical trauma and speeds patient recovery. The faster recovery rate also makes the system cost effective for patients. The digital image processing software used with the device was originally developed by the NASA Glenn Research Center to conduct computer simulations of satellite positioning in space. It was later modified to reflect lessons learned in enhancing photographic images in support of the Center's microgravity program. Glenn's Photovoltaic Branch and Graphics and Visualization Lab (G-VIS) computer programmers and software developers enhanced and speed up graphic imaging for this application. Mary Vickerman at Glenn developed algorithms that enabled Micro Medical Devices to eliminate interference and improve the images.

  11. Neuro-endoscopic management of intraventricular neurocysticercosis (NCC).

    PubMed

    Husain, M; Jha, D K; Rastogi, M; Husain, N; Gupta, R K

    2007-01-01

    Various approaches including endoscopy have been used for the treatment of intraventricular and cisternal NCC. We present our technique of Neuro-endoscopic management of intraventricular NCC. Twenty-one cases, 13 females and 8 males (age range 12-50 years; mean, 25.7 years), of intraventricular NCC [lateral (n = 6), third (n = 6), fourth (n = 10) ventricles including a patient with both lateral and third ventricular cysts] producing obstructive hydrocephalus formed the group of study. Gaab Universal Endoscope System along with 4 mm 0 degrees and 30 degrees rigid telescopes were used through a frontal burr-hole for removal of intraventricular including intra-fourth ventricular (n = 10) NCC. Endoscopic third ventriculostomy (ETV) was done for internal cerebrospinal fluid (CSF) diversion. Average follow up was 18 months. Complete (n = 18) or partial (n = 2) removal of NCC was done in 20 patients, while a cyst located at foramen of Monro slipped and migrated to occipital or temporal horn in 1 patient. Thirty-degree 4-mm rigid telescope provided excellent image quality with ability to address even intra-fourth ventricular NCC through the dilated aqueduct using a curved tip catheter. No patient required further surgery for their hydrocephalus. There was no operative complication and post-operative ventriculitis was not seen in any case despite partial removal of NCC. Neuro-endoscopic surgery is an effective treatment modality for patients with intraventricular NCC. It effectively restores CSF flow and is capable of removing cysts completely or partially from accessible locations causing mass effect. Partial removal or rupture of the cyst does not affect the clinical outcome of the patients.

  12. Successful Emergency Endoscopic Treatment of Gastric Outlet Obstruction due to Gastric Bezoar with Gastric Pneumatosis

    PubMed Central

    Honda, Hirokazu; Ikeya, Takashi; Kashiwagi, Erika; Okada, Shuichi; Fukuda, Katsuyuki

    2017-01-01

    Gastric bezoars are rare and are usually found incidentally. They can sometimes cause severe complications, including gastric outlet obstruction (GOO) or gastric pneumatosis (GP). In cases of bezoars with GP, the optimal treatment strategy has not yet been defined. We report the case of an 89-year-old man with a history of type 2 diabetes mellitus and hypertension who presented to our emergency room with a 2-day history of upper abdominal pain, nausea, and vomiting. Physical examination revealed no rebound tenderness or guarding, and laboratory values revealed no elevation of the serum lactate level. A computed tomography scan of the abdomen showed a dilated stomach with significant fluid collection, GOO, and GP due to a 42 × 40 mm mass composed of fat and air densities. Emergency esophagogastroduodenoscopy revealed two gastric bezoars, one of which was incarcerated in the pyloric region. We used various endoscopic devices to successfully break and remove the bezoars. We used endoscopic forceps and a water jet followed by an endoscopic snare to cut the bezoars into several pieces and remove them with an endoscopic net. Follow-up endoscopy confirmed that the gastric bezoar had been completely removed. As seen in this case, endoscopic treatment may be a safe and viable option for the extraction of gastric bezoars presenting with GOO and GP. PMID:29430223

  13. Successful Emergency Endoscopic Treatment of Gastric Outlet Obstruction due to Gastric Bezoar with Gastric Pneumatosis.

    PubMed

    Honda, Hirokazu; Ikeya, Takashi; Kashiwagi, Erika; Okada, Shuichi; Fukuda, Katsuyuki

    2017-01-01

    Gastric bezoars are rare and are usually found incidentally. They can sometimes cause severe complications, including gastric outlet obstruction (GOO) or gastric pneumatosis (GP). In cases of bezoars with GP, the optimal treatment strategy has not yet been defined. We report the case of an 89-year-old man with a history of type 2 diabetes mellitus and hypertension who presented to our emergency room with a 2-day history of upper abdominal pain, nausea, and vomiting. Physical examination revealed no rebound tenderness or guarding, and laboratory values revealed no elevation of the serum lactate level. A computed tomography scan of the abdomen showed a dilated stomach with significant fluid collection, GOO, and GP due to a 42 × 40 mm mass composed of fat and air densities. Emergency esophagogastroduodenoscopy revealed two gastric bezoars, one of which was incarcerated in the pyloric region. We used various endoscopic devices to successfully break and remove the bezoars. We used endoscopic forceps and a water jet followed by an endoscopic snare to cut the bezoars into several pieces and remove them with an endoscopic net. Follow-up endoscopy confirmed that the gastric bezoar had been completely removed. As seen in this case, endoscopic treatment may be a safe and viable option for the extraction of gastric bezoars presenting with GOO and GP.

  14. NOViSE: a virtual natural orifice transluminal endoscopic surgery simulator.

    PubMed

    Korzeniowski, Przemyslaw; Barrow, Alastair; Sodergren, Mikael H; Hald, Niels; Bello, Fernando

    2016-12-01

    Natural orifice transluminal endoscopic surgery (NOTES) is a novel technique in minimally invasive surgery whereby a flexible endoscope is inserted via a natural orifice to gain access to the abdominal cavity, leaving no external scars. This innovative use of flexible endoscopy creates many new challenges and is associated with a steep learning curve for clinicians. We developed NOViSE-the first force-feedback-enabled virtual reality simulator for NOTES training supporting a flexible endoscope. The haptic device is custom-built, and the behaviour of the virtual flexible endoscope is based on an established theoretical framework-the Cosserat theory of elastic rods. We present the application of NOViSE to the simulation of a hybrid trans-gastric cholecystectomy procedure. Preliminary results of face, content and construct validation have previously shown that NOViSE delivers the required level of realism for training of endoscopic manipulation skills specific to NOTES. VR simulation of NOTES procedures can contribute to surgical training and improve the educational experience without putting patients at risk, raising ethical issues or requiring expensive animal or cadaver facilities. In the context of an experimental technique, NOViSE could potentially facilitate NOTES development and contribute to its wider use by keeping practitioners up to date with this novel surgical technique. NOViSE is a first prototype, and the initial results indicate that it provides promising foundations for further development.

  15. Endoscopic sleeve gastroplasty (the Apollo method): a new approach to obesity management.

    PubMed

    López-Nava Breviere, Gontrand; Bautista-Castaño, Inmaculada; Fernández-Corbelle, Juan Pedro; Trell, Marta

    2016-04-01

    Many obese patients cannot lose weight or reject conventional obesity management. Endoscopic sleeve gastroplasty (the Apollo method) is a pioneering coadjuvant, interventionist technique for the integral management of obesity. The goals of this study were to report safety and efficacy results obtained at 6 months in patients undergoing endoscopic sleeve gastroplasty. A prospective study was performed in 55 patients (13 males, 42 females) who were subjected to the Apollo technique; mean age was 43.5 years (range 25-60) and mean BMI was 37.7 kg/m2 (range 30-48). All received multidisciplinary follow-up for weight loss. Weight changes and presence of complications were assessed. Through the endoscope a triangular pattern suture is performed consisting of approximately 3-6 transmural (mucosa to serosa) stitches, using a cinch device to bring them nearer and form a plication. A total of 6-8 plications are used to provide a tubular or sleeve-shaped restriction to the gastric cavity. No major complications developed and patients were discharged at 24 hours following the procedure. Endoscopic and radiographic follow-up at 6 months post-procedure showed a well preserved tubular form to the stomach. After 6 months patients had lost 18.9 kg and 55.3% of excess weight. Endoscopic sleeve gastroplasty, together with dietary and psycho-behavioral changes, is a safe, effective technique in the coadjuvant management of obese patients.

  16. Reprocessing anesthesia instruments and devices.

    PubMed

    Ball, K

    2000-02-01

    Reprocessing anesthesia instruments and devices can often present a challenge for anesthesia providers because anesthesia devices have become more complex, cross-contamination with disease-forming pathogens can occur, and the importance of appropriate reprocessing may not be fully understood. Based on accepted practice recommendations, regulations, and research, reprocessing must be performed by skilled individuals who understand asepsis, cleaning, disinfection, and sterilization principles. This article describes the art of reprocessing and includes highlighted information on recommended practices, Spaulding's classifications, personal protective attire, precleaning, leak testing of flexible endoscopes, device disassembly, cleaning supplies and solutions, cleaning methods, rinsing, reassembly of the device, inspection, disinfection, and sterilization.

  17. Endoscopic full-thickness resection in the colorectum with a novel over-the-scope device: first experience.

    PubMed

    Schmidt, Arthur; Bauerfeind, Peter; Gubler, Christoph; Damm, Michael; Bauder, Markus; Caca, Karel

    2015-08-01

    Endoscopic full-thickness resection (EFTR) in the lower gastrointestinal tract may be a valuable therapeutic and diagnostic approach for a variety of indications. Although feasibility of EFTR has been demonstrated, there is a lack of safe and effective endoscopic devices for routine use. The aim of this study was to investigate the efficacy and safety of a novel over-the-scope device for colorectal EFTR. Between July 2012 and July 2014, 25 patients underwent EFTR at two tertiary referral centers. All resections were performed using the full-thickness resection device (FTRD; Ovesco Endoscopy, Tübingen, Germany). Data were collected retrospectively. Indications for EFTR were: recurrent or incompletely resected adenoma with nonlifting sign (n = 11), untreated adenoma and nonlifting sign (n = 2), adenoma involving the appendix (n = 5), flat adenoma in a patient with coagulopathy (n = 1), diagnostic re-resection after incomplete resection of a T1 carcinoma (n = 2), adenoma involving a diverticulum (n = 1), submucosal tumor (n = 2), and diagnostic resection in a patient with suspected Hirschsprung's disease (n = 1). In one patient, the lesion could not be reached because of a sigmoid stenosis. In the other patients, resection of the lesion was macroscopically complete and en bloc in 20/24 patients (83.3 %). The mean diameter of the resection specimen was 24 mm (range 12 - 40 mm). The R0 resection rate was 75.0 % (18/24), and full-thickness resection was histologically confirmed in 87.5 %. No perforations or major bleeding were observed during or after resection. Two patients developed postpolypectomy syndrome, which was managed with antibiotic therapy. Full-thickness resection in the lower gastrointestinal tract with the novel FTRD was feasible and effective. Prospective studies are needed to further evaluate the device and technique. © Georg Thieme Verlag KG Stuttgart · New York.

  18. Endoscopic cystoventriculostomy and ventriculo-cysternostomy using a 2.0 micron fiber guided cw laser in children with hydrocephalus

    NASA Astrophysics Data System (ADS)

    Ludwig, Hans C.; Kruschat, Thomas; Knobloch, Torsten; Rostasy, Kevin M.; Teichmann, Heinrich O.; Buchfelder, Michael

    2005-08-01

    Preterm infants have a high incidence of post hemorrhagic or post infectious hydrocephalus often associated with ventricular or arachnoic cysts which carry a high risk of entrapment of cerebrospinal fluid (CSF). In these cases fenestration and opening of windows within the separating membranes are neurosurgical options. In occlusive hydrocephalus caused by aquaeductal stenosis 3rd ventriculostomy is the primary choice of the operative procedures. Although Nd:YAG and diode lasers have already been used in neuroendoscopic procedures, neurosurgeons avoid the use of high energy lasers in proximity to vital structures because of potential side effects. We have used a recently developed diode pumped solid state (DPSS) laser emitting light at a wavelength of 2.0 micron (Revolix TM LISA laser products, Katlenburg, Germany), which can be delivered through silica fibres towards endoscopic targets. From July 2002 until May 2005 22 endoscopic procedures in 20 consecutive patients (age 3 months to 12 years old) were performed. Most children suffered from complex post hemorrhagic and post infectious hydrocephalus, in whom ventriculoperitoneal shunt devices failed to restore a CSF equilibrium due to entrapment of CSF pathways by the cysts. We used two different endoscopes, a 6 mm Neuroendoscope (Braun Aesculap, Melsungen, Germany) and a 4 mm miniature Neuroscope (Storz, Tuttlingen, Germany). The endoscopes were connected to a standard camera and TV monitor, the laser energy was introduced through a 365 micron core diameter bare ended silica fibre (PercuFib, LISA laser products, Katlenburg, Germany) through the endoscope's working channel. The continuous wave laser was operated at power levels from 5 to 15 Watt in continuous and chopped mode. The frequency of the laser in chopped mode was varied between 5 and 20 Hz. All patients tolerated the procedure well. No immediate or long term side effects were noted. In 3 patients with cystic compression of the 4th ventricle, insertion of a shunt device could be avoided. All 3rd ventriculostomies were sufficient for therapy of hydrocephalus, postoperatively MRI scans showed a bright flow void signal. The authors conclude that the use of the new Revolix laser enables safe and effective procedures in neuroendoscopy.

  19. Biopsy using a Magnetic Capsule Endoscope Carrying, Releasing, and Retrieving Untethered Microgrippers

    PubMed Central

    Yim, Sehyuk; Gultepe, Evin; Gracias, David H.

    2014-01-01

    This paper proposes a new wireless biopsy method where a magnetically actuated untethered soft capsule endoscope carries and releases a large number of thermo-sensitive, untethered microgrippers (μ-grippers) at a desired location inside the stomach and retrieves them after they self-fold and grab tissue samples. We describe the working principles and analytical models for the μ-gripper release and retrieval mechanisms, and evaluate the proposed biopsy method in ex vivo experiments. This hierarchical approach combining the advanced navigation skills of centimeter-scaled untethered magnetic capsule endoscopes with highly parallel, autonomous, submillimeter scale tissue sampling μ-grippers offers a multifunctional strategy for gastrointestinal capsule biopsy. PMID:24108454

  20. 21 CFR 884.4160 - Unipolar endoscopic coagulator-cutter and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... temperatures by directing a high frequency electrical current through the tissue between an energized probe and... generator, probes and electrical cables, and a patient grounding plate. This generic type of device does not...

  1. 21 CFR 884.4160 - Unipolar endoscopic coagulator-cutter and accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... temperatures by directing a high frequency electrical current through the tissue between an energized probe and... generator, probes and electrical cables, and a patient grounding plate. This generic type of device does not...

  2. 21 CFR 884.4160 - Unipolar endoscopic coagulator-cutter and accessories.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... temperatures by directing a high frequency electrical current through the tissue between an energized probe and... generator, probes and electrical cables, and a patient grounding plate. This generic type of device does not...

  3. 21 CFR 884.4160 - Unipolar endoscopic coagulator-cutter and accessories.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... temperatures by directing a high frequency electrical current through the tissue between an energized probe and... generator, probes and electrical cables, and a patient grounding plate. This generic type of device does not...

  4. 21 CFR 884.4160 - Unipolar endoscopic coagulator-cutter and accessories.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... temperatures by directing a high frequency electrical current through the tissue between an energized probe and... generator, probes and electrical cables, and a patient grounding plate. This generic type of device does not...

  5. Predictive factors suggesting an underestimation of gastric lesions initially diagnosed as adenomas by forceps biopsy.

    PubMed

    Ko, Sung Jun; Yang, Min A; Yun, So Hee; Park, Moon Sik; Han, Shang Hoon; Cho, Jin Woong

    2016-03-01

    The endoscopic forceps biopsy of gastric lesion may provide inadequate specimens for a correct diagnosis of the entire lesion. Therefore, a histologic discrepancy may exist between specimens obtained by forceps biopsy and by endoscopic resection. The aim of this study was to evaluate the endoscopic characteristics of an underestimation in gastric carcinomas initially diagnosed as adenomas by forceps biopsy. We retrospectively reviewed 431 lesions diagnosed as gastric adenomas by forceps biopsy and resected by endoscopic submucosal dissection (ESD) between January 2008 and December 2011. The endoscopic findings were reviewed for location, size, gross appearance, ulceration, and surface color. We compared these variables between the adenoma group and the carcinoma group, as defined by the post-resection pathological findings. The mean patient age was 65.63±9.30 years in the adenoma group and 64.75±10.30 years in the carcinoma group. The mean size of the lesion was 21.04±8.65 mm in the adenoma group and 22.06±7.46 mm in the carcinoma group. In the multivariate analysis, high-grade dysplasia from endoscopic forceps biopsy and red discoloration were significant variables associated with carcinoma in post-resection histology. Gastric adenomatous lesions with endoscopic characteristics of surface redness and high-grade dysplasia on forceps biopsy should be resected completely by ESD because of the high possibility of an underestimation after ESD.

  6. Laser-supported diaphanoscopy: an innovative technique for locating gastric stromal tumors in gastroscopic-laparoscopic rendezvous: a case series.

    PubMed

    Patrzyk, M; Schreiber, A; Heidecke, C D; Glitsch, A

    2009-12-01

    Development of an innovative method of endoscopic laser-supported diaphanoscopy, for precise demonstration of the location of gastrointestinal stromal tumors (GISTs) at laparoscopy is described. The equipment consists of a light transmission cable with an anchoring system for the gastric mucosa, a connecting system for the light source, and the laser light source itself. During surgery, transillumination by laser is used to show the shape of the tumor. The resection margins are then marked by electric coagulation. Ten patients have been successfully treated using this technique in laparoscopic-endoscopic rendezvous procedures. Average time of surgery was 123 minutes. The time for marking the shape of the tumor averaged 16 minutes. Depending on tumor location and size, 4-7 marks were used, and resection margins were 4-15 mm. This new and effective technique facilitates precise locating of gastric GISTs leading to exact and tissue-sparing transmural laparoscopic resections. Georg Thieme Verlag KG Stuttgart New York.

  7. Stray energy transfer during endoscopy.

    PubMed

    Jones, Edward L; Madani, Amin; Overbey, Douglas M; Kiourti, Asimina; Bojja-Venkatakrishnan, Satheesh; Mikami, Dean J; Hazey, Jeffrey W; Arcomano, Todd R; Robinson, Thomas N

    2017-10-01

    Endoscopy is the standard tool for the evaluation and treatment of gastrointestinal disorders. While the risk of complication is low, the use of energy devices can increase complications by 100-fold. The mechanism of increased injury and presence of stray energy is unknown. The purpose of the study was to determine if stray energy transfer occurs during endoscopy and if so, to define strategies to minimize the risk of energy complications. A gastroscope was introduced into the stomach of an anesthetized pig. A monopolar generator delivered energy for 5 s to a snare without contacting tissue or the endoscope itself. The endoscope tip orientation, energy device type, power level, energy mode, and generator type were varied to mimic in vivo use. The primary outcome (stray current) was quantified as the change in tissue temperature (°C) from baseline at the tissue closest to the tip of the endoscope. Data were reported as mean ± standard deviation. Using the 60 W coag mode while changing the orientation of the endoscope tip, tissue temperature increased by 12.1 ± 3.5 °C nearest the camera lens (p < 0.001 vs. all others), 2.1 ± 0.8 °C nearest the light lens, and 1.7 ± 0.4 °C nearest the working channel. Measuring temperature at the camera lens, reducing power to 30 W (9.5 ± 0.8 °C) and 15 W (8.0 ± 0.8 °C) decreased stray energy transfer (p = 0.04 and p = 0.002, respectively) as did utilizing the low-voltage cut mode (6.6 ± 0.5 °C, p < 0.001). An impedance-monitoring generator significantly decreased the energy transfer compared to a standard generator (1.5 ± 3.5 °C vs. 9.5 ± 0.8 °C, p < 0.001). Stray energy is transferred within the endoscope during the activation of common energy devices. This could result in post-polypectomy syndrome, bleeding, or perforation outside of the endoscopist's view. Decreasing the power, utilizing low-voltage modes and/or an impedance-monitoring generator can decrease the risk of complication.

  8. A Clinical Wide-Field Fluorescence Endoscopic Device for Molecular Imaging Demonstrating Cathepsin Protease Activity in Colon Cancer

    PubMed Central

    Sensarn, Steven; Zavaleta, Cristina L.; Segal, Ehud; Rogalla, Stephan; Lee, Wansik; Gambhir, Sanjiv S.; Bogyo, Matthew; Contag, Christopher H.

    2017-01-01

    Purpose Early and effective detection of cancers of the gastrointestinal tract will require novel molecular probes and advances in instrumentation that can reveal functional changes in dysplastic and malignant tissues. Here, we describe adaptation of a wide-field clinical fiberscope to perform wide-field fluorescence imaging while preserving its white-light capability for the purpose of providing wide-field fluorescence imaging capability to point-of-care microscopes. Procedures We developed and used a fluorescent fiberscope to detect signals from a quenched probe, BMV109, that becomes fluorescent when cleaved by, and covalently bound to, active cathepsin proteases. Cathepsins are expressed in inflammation- and tumor-associated macrophages as well as directly from tumor cells and are a promising target for cancer imaging. The fiberscope has a 1-mm outer diameter enabling validation via endoscopic exams in mice, and therefore we evaluated topically applied BMV109 for the ability to detect colon polyps in an azoxymethane-induced colon tumor model in mice. Results This wide-field endoscopic imaging device revealed consistent and clear fluorescence signals from BMV109 that specifically localized to the polypoid regions as opposed to the normal adjacent colon tissue (p < 0.004) in the murine colon carcinoma model. Conclusions The sensitivity of detection of BMV109 with the fluorescence fiberscope suggested utility of these tools for early detection at hard-to-reach sites. The fiberscope was designed to be used in conjunction with miniature, endoscope-compatible fluorescence microscopes for dual wide-field and microscopic cancer detection. PMID:27154508

  9. Endoscopic endonasal transsphenoidal surgery using the iArmS operation support robot: initial experience in 43 patients.

    PubMed

    Ogiwara, Toshihiro; Goto, Tetsuya; Nagm, Alhusain; Hongo, Kazuhiro

    2017-05-01

    Objective The intelligent arm-support system, iArmS, which follows the surgeon's arm and automatically fixes it at an adequate position, was developed as an operation support robot. iArmS was designed to support the surgeon's forearm to prevent hand trembling and to alleviate fatigue during surgery with a microscope. In this study, the authors report on application of this robotic device to endoscopic endonasal transsphenoidal surgery (ETSS) and evaluate their initial experiences. Methods The study population consisted of 43 patients: 29 with pituitary adenoma, 3 with meningioma, 3 with Rathke's cleft cyst, 2 with craniopharyngioma, 2 with chordoma, and 4 with other conditions. All patients underwent surgery via the endonasal transsphenoidal approach using a rigid endoscope. During the nasal and sphenoid phases, iArmS was used to support the surgeon's nondominant arm, which held the endoscope. The details of the iArmS and clinical results were collected. Results iArmS followed the surgeon's arm movement automatically. It reduced the surgeon's fatigue and stabilized the surgeon's hand during ETSS. Shaking of the video image decreased due to the steadying of the surgeon's scope-holding hand with iArmS. There were no complications related to use of the device. Conclusions The intelligent armrest, iArmS, seems to be safe and effective during ETSS. iArmS is helpful for improving the precision and safety not only for microscopic neurosurgery, but also for ETSS. Ongoing advances in robotics ensure the continued evolution of neurosurgery.

  10. Management and endoscopic techniques for digestive foreign body and food bolus impaction.

    PubMed

    Chauvin, Armelle; Viala, Jerome; Marteau, Philippe; Hermann, Philippe; Dray, Xavier

    2013-07-01

    Ingested foreign bodies, food bolus impaction, migration or retention of medical devices are frequent, in children as well as in adults. Most of these foreign bodies will naturally pass through the gastro-intestinal tract. Complications are rare but sometimes severe (oesophageal perforations are the most frequent and most feared). We aimed to review the literature on therapeutic management of digestive foreign bodies and food bolus impaction, with special focus on endoscopic indications, material, timing and techniques for removal. The role of the gastroenterologist is to recognise specific situations and to plan endoscopic removal in a timely manner with the most adequate conditions and extraction tools. Risk factors and underlying pathology, for example eosinophilic esophagitis, must be investigated and if necessary treated. Copyright © 2012 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  11. Fully wireless pressure sensor based on endoscopy images

    NASA Astrophysics Data System (ADS)

    Maeda, Yusaku; Mori, Hirohito; Nakagawa, Tomoaki; Takao, Hidekuni

    2018-04-01

    In this paper, the result of developing a fully wireless pressure sensor based on endoscopy images for an endoscopic surgery is reported for the first time. The sensor device has structural color with a nm-scale narrow gap, and the gap is changed by air pressure. The structural color of the sensor is acquired from camera images. Pressure detection can be realized with existing endoscope configurations only. The inner air pressure of the human body should be measured under flexible-endoscope operation using the sensor. Air pressure monitoring, has two important purposes. The first is to quantitatively measure tumor size under a constant air pressure for treatment selection. The second purpose is to prevent the endangerment of a patient due to over transmission of air. The developed sensor was evaluated, and the detection principle based on only endoscopy images has been successfully demonstrated.

  12. Scanning fiber endoscopy with highly flexible, 1-mm catheterscopes for wide-field, full-color imaging

    PubMed Central

    Lee, Cameron M.; Engelbrecht, Christoph J.; Soper, Timothy D.; Helmchen, Fritjof; Seibel, Eric J.

    2011-01-01

    In modern endoscopy, wide field of view and full color are considered necessary for navigating inside the body, inspecting tissue for disease and guiding interventions such as biopsy or surgery. Current flexible endoscope technologies suffer from reduced resolution when device diameter shrinks. Endoscopic procedures today using coherent fiber bundle technology, on the scale of 1 mm, are performed with such poor image quality that the clinician’s vision meets the criteria for legal blindness. Here, we review a new and versatile scanning fiber imaging technology and describe its implementation for ultrathin and flexible endoscopy. This scanning fiber endoscope (SFE) or catheterscope enables high quality, laser-based, video imaging for ultrathin clinical applications while also providing new options for in vivo biological research of subsurface tissue and high resolution fluorescence imaging. PMID:20336702

  13. The Spatial Predilection for Early Esophageal Squamous Cell Neoplasia: A "Hot Zone" for Endoscopic Screening and Surveillance.

    PubMed

    Wang, Wen-Lun; Chang, I-Wei; Chen, Chien-Chuan; Chang, Chi-Yang; Lin, Jaw-Town; Mo, Lein-Ray; Wang, Hsiu-Po; Lee, Ching-Tai

    2016-04-01

    Early esophageal squamous cell neoplasias (ESCNs) are easily missed with conventional white-light endoscopy. This study aimed to assess whether early ESCNs have a spatial predilection and the patterns of recurrence after endoscopic treatment. We analyzed the circumferential and longitudinal location of early ESCNs, as well as their correlations with exposure to carcinogens in a cohort of 162 subjects with 248 early ESCNs; 219 of which were identified by screening and 29 by surveillance endoscopy. The circumferential location was identified using a clock-face orientation, and the longitudinal location was identified according to the distance from the incisor. The most common circumferential and longitudinal distributions of the early ESCNs were found in the 6 to 9 o'clock quadrant (38.5%) and at 26 to 30 cm from the incisor (41.3%), respectively. A total of 163 lesions (75%) were located in the lower hemisphere arc, and 149 (68.4%) were located at 26 to 35 cm from the incisor. One hundred eleven (51%) early ESCNs were centered within the "hot zone" (i.e., lower hemisphere arc of the esophagus at 26 to 35 cm from the incisor), which comprised 20% of the esophageal area. Exposure to alcohol, betel nut, or cigarette was risk factors for the development of early ESCNs in the lower hemisphere. After complete endoscopic treatment, the mean annual incidence of metachronous tumors was 10%. In addition, 43% of the metachronous recurrent neoplasias developed within the "hot zone." Cox regression analysis revealed that the index tumor within the hot zone (hazard ratio [HR]: 3.19; 95% confidence interval [CI]: 1.17-8.68; P = 0.02) and the presence of numerous Lugol-voiding lesions in the esophageal background mucosa were independent predictors for metachronous recurrence (HR: 4.61; 95% CI: 1.36-15.56; P = 0.01). We identified a hot zone that may be used to enhance the detection of early ESCNs during endoscopic screening and surveillance, especially in areas that lack resources and have a high prevalence of ESCNs.

  14. Brain surgery

    MedlinePlus

    Craniotomy; Surgery - brain; Neurosurgery; Craniectomy; Stereotactic craniotomy; Stereotactic brain biopsy; Endoscopic craniotomy ... cut depends on where the problem in the brain is located. The surgeon creates a hole in ...

  15. Evaluation of the microbicidal efficacy of Steris System I for digestive endoscopes using GERMANDE and ASTM validation protocols.

    PubMed

    Duc, D L; Ribiollet, A; Dode, X; Ducel, G; Marchetti, B; Calop, J

    2001-06-01

    In the light of more and more invasive procedures being carried out in digestive endoscopy using sterile devices, it appears necessary to put in place a process of endoscope reprocessing capable of ensuring the complete elimination of micro-organisms contaminating the device. We undertook a study of the microbial efficacy of STERIS SYSTEM 1 (SS1) which purports to achieve this objective. The channels of a gastroscope and a colonoscope were contaminated with suspensions of Pseudomonas aeruginosa, Aspergillus niger and Bacillus subtilis spores. Two procedures were then followed: (1) manual washing only, and (2) treatment in SS1 without prewashing. Recoveries of organisms were made from each channel according to a standard methodology to discover any survivors. Contamination controls we re assessed to measure the logarithmic reduction between the initial contamination and that recovered from the channels. Six cycles per micro-organisms, per type of endoscope, and per type of procedure were carried out. From an initial contamination leve l of 10(6) micro-organisms per endoscope, no micro-organisms were recovered in 35 of the 36 cycles with the SS1. In one cycle with the colonoscope, three B. subtilis organisms were recovered from the channels. Washing only gave microbial reductions which varied according to the micro-organism tested. The maximum reduction with washing alone was by a factor of 10(3 +/- 0.1)for B. subtilis and the minimum reduction factor was 10(3 +/- 0.3)for P. aeruginosa. Considering the results obtained with SS1 without prewashing and the efficacy obtained from washing only, the washing step offers an additional antimicrobial assurance reduction factor of between 10 and 103.1. This study shows that SS1, integrated into an overall reprocessing procedure for digestive endoscopes, is capable of delivering the complete elimination of contaminating micro-organisms in a reduced time and eliminates the toxic risk of reprocessing associated with aldehyde based disinfectants. Copyright 2001 The Hospital Infection Society.

  16. Natural orifice transgastric endoscopic wedge hepatic resection in an experimental model using an intuitively controlled master and slave transluminal endoscopic robot (MASTER).

    PubMed

    Phee, S J; Ho, K Y; Lomanto, D; Low, S C; Huynh, V A; Kencana, A P; Yang, K; Sun, Z L; Chung, S C Sydney

    2010-09-01

    The lack of triangulation of standard endoscopic devices limits the degree of freedom for surgical maneuvers during natural orifice transluminal endoscopic surgery (NOTES). This study explored the feasibility of adapting an intuitively controlled master and slave transluminal endoscopic robot (MASTER) the authors developed to facilitate wedge hepatic resection in NOTES. The MASTER consists of a master controller, a telesurgical workstation, and a slave manipulator that holds two end-effectors: a grasper, and a monopolar electrocautery hook. The master controller is attached to the wrist and fingers of the operator and connected to the manipulator by electrical and wire cables. Movements of the operator are detected and converted into control signals driving the slave manipulator via a tendon-sheath power transmission mechanism allowing nine degrees of freedom. Using this system, wedge hepatic resection was performed through the transgastric route on two female pigs under general anesthesia. Entry into the peritoneal cavity was via a 10-mm incision made on the anterior wall of the stomach by the electrocautery hook. Wedge hepatic resection was performed using the robotic grasper and hook. Hemostasis was achieved with the electrocautery hook. After the procedure, the resected liver tissue was retrieved through the mouth using the grasper. Using the MASTER, transgastric wedge hepatic resection was successfully performed on two pigs with no laparoscopic assistance. The entire procedure took 9.4 min (range, 8.5-10.2 min), with 7.1 min (range, 6-8.2 min) spent on excision of the liver tissue. The robotics-controlled device was able to grasp, retract, and excise the liver specimen successfully in the desired plane. This study demonstrated for the first time that the MASTER could effectively mitigate the technical constraints normally encountered in NOTES procedures. With it, the triangulation of surgical tools and the manipulation of tissue became easy, and wedge hepatic resection could be accomplished successfully without the need for assistance using laparoscopic instruments.

  17. A Real-Time Clinical Endoscopic System for Intraluminal, Multiplexed Imaging of Surface-Enhanced Raman Scattering Nanoparticles

    PubMed Central

    Garai, Ellis; Loewke, Nathan O.; Rogalla, Stephan; Mandella, Michael J.; Felt, Stephen A.; Friedland, Shai; Liu, Jonathan T. C.; Gambhir, Sanjiv S.; Contag, Christopher H.

    2015-01-01

    The detection of biomarker-targeting surface-enhanced Raman scattering (SERS) nanoparticles (NPs) in the human gastrointestinal tract has the potential to improve early cancer detection; however, a clinically relevant device with rapid Raman-imaging capability has not been described. Here we report the design and in vivo demonstration of a miniature, non-contact, opto-electro-mechanical Raman device as an accessory to clinical endoscopes that can provide multiplexed molecular data via a panel of SERS NPs. This device enables rapid circumferential scanning of topologically complex luminal surfaces of hollow organs (e.g., colon and esophagus) and produces quantitative images of the relative concentrations of SERS NPs that are present. Human and swine studies have demonstrated the speed and simplicity of this technique. This approach also offers unparalleled multiplexing capabilities by simultaneously detecting the unique spectral fingerprints of multiple SERS NPs. Therefore, this new screening strategy has the potential to improve diagnosis and to guide therapy by enabling sensitive quantitative molecular detection of small and otherwise hard-to-detect lesions in the context of white-light endoscopy. PMID:25923788

  18. Endoscopic Endonasal Management of Craniopharyngioma.

    PubMed

    Zacharia, Brad E; Amine, Muhamad; Anand, Vijay; Schwartz, Theodore H

    2016-02-01

    Craniopharyngioma is a rare clinical entity that poses a significant management challenge given their location and propensity to recur. As part of a minimally disruptive treatment paradigm, the expanded endonasal approach has the potential to improve rates of resection, improve postoperative visual recovery, and minimize surgical morbidity. This article updates the otolaryngologic community on the basic principles and techniques regarding the incorporation of the endoscopic, endonasal approach in the management paradigm of craniopharyngioma. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. [Simplified identification and filter device of carbon dioxide].

    PubMed

    Mei, Xue-qin; Zhang, Yi-ping

    2009-11-01

    This paper presents the design and implementation ways of a simplified device to identify and filter carbon dioxide. The gas went through the test interface which had wet litmus paper before entering the abdominal cavity. Carbon dioxide dissolving in water turned acidic, making litmus paper change color to identify carbon dioxide, in order to avoid malpractice by connecting the wrong gas when making Endoscopic surgery.

  20. Loop-anchor purse-string closure of gastrotomy in NOTES(R) procedures: survival studies in a porcine model.

    PubMed

    Romanelli, John R; Desilets, David J; Chapman, Christopher N; Surti, Vihar C; Lovewell, Carolanne; Earle, David B

    2010-12-01

    Transgastric NOTES(®) procedures remain without a simple method to close the gastrotomy. In four survival swine studies, we have tested a novel gastric closure device: the loop-anchor purse-string (LAPS) closure system. In four anesthetized pigs, an endoscopic gastrotomy was performed. Four loop anchors were arrayed in a 2-cm square pattern around the gastrotomy. The endoscope was passed into the abdominal cavity, and the gastrotomy was cinched closed. Procedure times ranged from 50-180 minutes. Three pigs survived 14 days. One animal was sacrificed early due to signs of sepsis. Another animal developed fevers and was treated with antibiotics. At necropsy, there were no abscesses, including in the septic animal. Histologic examination revealed evidence of healing in all animals. The LAPS system holds promise with early success in an animal model. Future human studies are needed to determine viability as a human visceral closure device.

  1. Upper Nasopharyngeal Corridor for Transnasal Endoscopic Drainage of Petroclival Cholesterol Granulomas: Alternative Access in Conchal Sphenoid Patients.

    PubMed

    Turan, Nefize; Baum, Griffin R; Holland, Christopher M; Ahmad, Faiz U; Henriquez, Oswaldo A; Pradilla, Gustavo

    2016-03-01

    Background Cholesterol granulomas arising at the petrous apex can be treated via traditional open surgical, endoscopic, and endoscopic-assisted approaches. Endoscopic approaches require access to the sphenoid sinus, which is technically challenging in patients with conchal sphenoidal anatomy. Clinical Presentation A 55-year-old woman presented with intermittent headaches and tinnitus. Formal audiometry demonstrated moderately severe bilateral hearing loss. CT of the temporal bones and sella revealed a well-demarcated expansile lytic mass. MRI of the face, orbit, and neck showed a right petrous apex mass measuring 22 × 18 × 19 mm that was hyperintense on T1- and T2-weighted images without enhancement, consistent with a cholesterol granuloma. The patient had a conchal sphenoidal anatomy. Operative Technique Herein, we present an illustrative case of a low-lying petroclival cholesterol granuloma in a patient with conchal sphenoidal anatomy to describe an alternative high nasopharyngeal corridor for endoscopic transnasal transclival access. Postoperative Course Postoperatively, the patient's symptoms recovered and no complications occurred. Follow-up imaging demonstrated a patent drainage tract without evidence of recurrence. Conclusion In patients with a conchal sphenoid sinus, endoscopic transnasal transclival access can be gained using a high nasopharyngeal approach. This corridor facilitates safe access to these lesions and others in this location.

  2. Design and performance of optical endoscopes for the early detection of cancer

    NASA Astrophysics Data System (ADS)

    Keenan, Maureen Molly

    Cancer is a multistage, heterogeneous disease that develops through a series of genetic mutations. Early stage cancer is most responsive to treatment but can be the hardest to detect due to its small size, lack of definitive symptoms and potential location deep in the body. Whole body imaging methods, MRI/CT/PET, lack the necessary resolution to detect cellular level abnormalities. Optical methods, which have sufficient resolution, can be miniaturized into endoscopes, which are necessary to overcome limited penetration of light into tissue. By combining optical coherence tomography (OCT) and fluorescence imaging methods it is possible to create endoscopes sensitive to molecular and structural changes. I applied a dual-modality 2mm diameter rigid endoscope to the study of the natural history of colon cancer in a mouse model, and later applied this knowledge to the design and characterization of a 0.8 mm dual-modality flexible probe for use in human fallopian tubes. By using this endoscope, which is introduced through the natural orifice and is compatible with existing hysteroscopes, high-risk women could be screened in a procedure at a similar level of invasiveness as a colonoscopy. Therefore, the endoscope fills this gap in clinical care for women at high-risk for ovarian cancer.

  3. Percutaneous Endoscopic Removal of a Lumbar Epidural Angiolipoma via Interlaminar Approach: A Technical Report.

    PubMed

    Ying, Guang-Yu; Yao, Ying; Shen, Fang; Ren, Yu-Cheng; Chen, Chien-Min; Zhu, Yong-Jian

    2017-03-01

    Although percutaneous endoscopic technique has been routinely used in the treatment of disk herniation, there are few reports on its application in the management of intraspinal tumors. We present a case report of lumbar epidural angiolipoma that was totally removed by percutaneous endoscopic technique. A 63-year-old man presented with a 4-month history of progressively worsening low back pain. No abnormal neurologic finding was noted on physical examination, and magnetic resonance imaging demonstrated a dorsally located L2-3 epidural lesion, suggestive of a noninfiltrating angiolipoma. During the operation, an 8-mm skin incision was made, and a dilator was bluntly inserted toward the interlaminar space, followed by insertion of a working cannula onto the ligamentum flavum and placement of the endoscope. The interlaminar space was enlarged by resection of part of the lower rim of the right L2 vertebral laminae, and the right side of the interlaminar ligamentum flavum was removed to expose the tumor. The tumor was totally removed piecemeal under endoscopic guidance, and pathologic examination confirmed the diagnosis of angiolipoma. This report supports the application of percutaneous endoscopic technique in the surgical resection of noninfiltrating extradural lumbar angiolipoma. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. High-density collagen patch prevents stricture after endoscopic circumferential submucosal dissection of the esophagus: a porcine model.

    PubMed

    Aoki, Shigehisa; Sakata, Yasuhisa; Shimoda, Ryo; Takezawa, Toshiaki; Oshikata-Miyazaki, Ayumi; Kimura, Hiromi; Yamamoto, Mihoko; Iwakiri, Ryuichi; Fujimoto, Kazuma; Toda, Shuji

    2017-05-01

    Extensive excision of the esophageal mucosa by endoscopic submucosal dissection (ESD) frequently evokes a luminal stricture. This study aimed to determine the efficacy of a high-density collagen patch for the prevention of esophageal stricture in extensive ESD. Six pigs underwent circumferential esophageal ESD under general anesthesia. In 3 pigs, artificial ulcers were covered by 2 collagen patches. The other 3 pigs underwent circumferential ESD only. The 2 collagen patches were settled onto the ulcer surface using a general endoscope and instruments. The collagen patch-treated group showed significantly better patency rates on both the oral and anal sides of the wound area compared with the control group at day 14. The mucosal re-epithelization ratio was significantly promoted, and the extent of mucosal inflammation and fibrosis was significantly decreased with the collagen patch treatment in the wound area. The frequency of cells positive α-smooth muscle actin was significantly reduced in the collagen patch-treated group compared with the control group. We have established a high-density collagen device that can reduce the esophageal stricture associated with extensive ESD. This easy-to-handle device would be useful during superficial esophageal cancer treatment by ESD. Copyright © 2017 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  5. Ultrahigh speed en face OCT capsule for endoscopic imaging

    PubMed Central

    Liang, Kaicheng; Traverso, Giovanni; Lee, Hsiang-Chieh; Ahsen, Osman Oguz; Wang, Zhao; Potsaid, Benjamin; Giacomelli, Michael; Jayaraman, Vijaysekhar; Barman, Ross; Cable, Alex; Mashimo, Hiroshi; Langer, Robert; Fujimoto, James G.

    2015-01-01

    Depth resolved and en face OCT visualization in vivo may have important clinical applications in endoscopy. We demonstrate a high speed, two-dimensional (2D) distal scanning capsule with a micromotor for fast rotary scanning and a pneumatic actuator for precision longitudinal scanning. Longitudinal position measurement and image registration were performed by optical tracking of the pneumatic scanner. The 2D scanning device enables high resolution imaging over a small field of view and is suitable for OCT as well as other scanning microscopies. Large field of view imaging for screening or surveillance applications can also be achieved by proximally pulling back or advancing the capsule while scanning the distal high-speed micromotor. Circumferential en face OCT was demonstrated in living swine at 250 Hz frame rate and 1 MHz A-scan rate using a MEMS tunable VCSEL light source at 1300 nm. Cross-sectional and en face OCT views of the upper and lower gastrointestinal tract were generated with precision distal pneumatic longitudinal actuation as well as proximal manual longitudinal actuation. These devices could enable clinical studies either as an adjunct to endoscopy, attached to an endoscope, or as a swallowed tethered capsule for non-endoscopic imaging without sedation. The combination of ultrahigh speed imaging and distal scanning capsule technology could enable both screening and surveillance applications. PMID:25909001

  6. Ultrahigh speed en face OCT capsule for endoscopic imaging.

    PubMed

    Liang, Kaicheng; Traverso, Giovanni; Lee, Hsiang-Chieh; Ahsen, Osman Oguz; Wang, Zhao; Potsaid, Benjamin; Giacomelli, Michael; Jayaraman, Vijaysekhar; Barman, Ross; Cable, Alex; Mashimo, Hiroshi; Langer, Robert; Fujimoto, James G

    2015-04-01

    Depth resolved and en face OCT visualization in vivo may have important clinical applications in endoscopy. We demonstrate a high speed, two-dimensional (2D) distal scanning capsule with a micromotor for fast rotary scanning and a pneumatic actuator for precision longitudinal scanning. Longitudinal position measurement and image registration were performed by optical tracking of the pneumatic scanner. The 2D scanning device enables high resolution imaging over a small field of view and is suitable for OCT as well as other scanning microscopies. Large field of view imaging for screening or surveillance applications can also be achieved by proximally pulling back or advancing the capsule while scanning the distal high-speed micromotor. Circumferential en face OCT was demonstrated in living swine at 250 Hz frame rate and 1 MHz A-scan rate using a MEMS tunable VCSEL light source at 1300 nm. Cross-sectional and en face OCT views of the upper and lower gastrointestinal tract were generated with precision distal pneumatic longitudinal actuation as well as proximal manual longitudinal actuation. These devices could enable clinical studies either as an adjunct to endoscopy, attached to an endoscope, or as a swallowed tethered capsule for non-endoscopic imaging without sedation. The combination of ultrahigh speed imaging and distal scanning capsule technology could enable both screening and surveillance applications.

  7. Endoscopic ultrasound for the characterization and staging of rectal cancer. Current state of the method. Technological advances and perspectives.

    PubMed

    Gersak, Mariana M; Badea, Radu; Graur, Florin; Hajja, Nadim Al; Furcea, Luminita; Dudea, Sorin M

    2015-06-01

    Endoscopic ultrasound is the most accurate type of examination for the assessment of rectal tumors. Over the years, the method has advanced from gray-scale examination to intravenous contrast media administration and to different types of elastography. The multimodal approach of tumors (transrectal, transvaginal) is adapted to each case. 3D ultrasound is useful for spatial representation and precise measurement of tumor formations, using CT/MR image reconstruction; color elastography is useful for tumor characterization and staging; endoscopic ultrasound using intravenous contrast agents can help study the amount of contrast agent targeted at the level of the tumor formations and contrast wash-in/wash-out time, based on the curves displayed on the device. The transvaginal approach often allows better visualization of the tumor than the transrectal approach. Performing the procedure with the rectal ampulla distended with contrast agent may be seen as an optimization of the examination methodology. All these aspects are additional methods for gray-scale endoscopic ultrasound, capable of increasing diagnostic accuracy. This paper aims at reviewing the progress of transrectal and transvaginal ultrasound, generically called endoscopic ultrasound, for rectal tumor diagnosis and staging, with emphasis on the current state of the method and its development trends.

  8. Coblation assisted transnasal endoscopic resection of nasopharyngeal cyst: 10 years experience and outcomes

    PubMed Central

    Wang, Qinying; Chen, Haihong; Wang, Shenqing

    2015-01-01

    Objectives: To determine the outcomes of coblation assisted transnasal endoscopic resection of nasopharyngeal cyst. Method: Retrospective chart review outcomes in 12 patients who underwent endoscopic resect cysts of the nasopharynx at our department between 2001 and 2010. Twelve patient, aged 28 to 71 years, with cysts of the nasopharynx. The outcome variables of complications and the rate of recurrence were analyzed, respectively. Results: In 12 cases, retention cysts in 2 cases, branchial cyst in 1 case, adenoid middle fossa cyst infection in 6 cases, Tornwaldt’s cyst in 3 cases. The use of the coblation device was associated with a significant decrease in blood loss. There were no postoperative complications, and the overall follow-up period was 2-7 years and shows no signs of recurrence. Conclusions: We describe transnasal endoscopic procedures to resect cysts of the nasopharynx. We found that radiofrequency coblation is a useful and safe tool associated with minimal blood loss in the resection of these cysts. In our experience, it has been a highly successful, safe, and effective procedure. PMID:26131108

  9. The role of endoscopic intervention in the management of inflammatory pancreatic fluid collections.

    PubMed

    Parihar, Vikrant; Ridgway, Paul F; Conlon, Kevin C; Huggett, Matthew; Ryan, Barbara M

    2017-04-01

    Pancreatic fluid collections (PFCs) are a frequent complication of pancreatitis, or less commonly, pancreatic trauma or surgery. The revised Atlanta Classification categorizes PFCs as acute or chronic, with further subclassification of acute collections into acute peripancreatic collections and acute necrotic collections and of chronic fluid collections into pseudocysts and walled-off pancreatic necrosis. Acute PFCs are generally only subjected to an intervention when they are infected and not responding to antibiotics and are not managed endoscopically. Chronic PFCs, both pseudocysts and walled-off pancreatic necrosis, require intervention only when symptomatic or enlarging over time. Endoscopic ultrasound-guided drainage has become the mainstay of management for chronic PFCs that require intervention. Developments in medical devices over the past few years have significantly simplified and shortened the duration of the procedure itself, but the optimum choice of stent in different clinical scenarios remains to be defined, as does the place of endoscopic necrosectomy. To optimize outcomes, these patients should undergo a careful preprocedure workup and discussion in a multidisciplinary environment and procedures should be carried out in high-volume pancreatic units.

  10. Gastric Bezoar Treatment by Endoscopic Fragmentation in Combination with Pepsi-Cola® Administration

    PubMed Central

    Iwamuro, Masaya; Yunoki, Naoko; Tomoda, Jun; Nakamura, Kazuhiro; Okada, Hiroyuki; Yamamoto, Kazuhide

    2015-01-01

    Patient: Male, 86 Final Diagnosis: Gastric bezoar Symptoms: — Medication: Cola Clinical Procedure: Endoscopic fragmentation after gastric lavage with Pepsi-Cola Specialty: Gastroenterology and Hepatology Objective: Unusual setting of medical care Background: Although bezoar dissolution by Coca-Cola® has been described in case reports and case series, to the best of our knowledge, the usefulness of other cola products such as Pepsi-Cola® has never been reported in the English literature. Case Report: An 86-year-old Taiwanese man was diagnosed with a gastric bezoar. Endoscopic fragmentation with a polypectomy snare was attempted twice but failed to remove the bezoar. Subsequently, 500 mL of Pepsi NEX Zero® was administered daily for 4 days via nasogastric tube. The bezoar was softened and successfully fragmented by the polypectomy snare and needle-knife devices on the third attempt. Conclusions: This report presents the first case of a gastric bezoar successfully treated by endoscopic fragmentation in combination with Pepsi-Cola® administration, suggesting the possible utility of cola beverages in bezoar treatment, regardless of product brands. PMID:26164451

  11. Identifying DNA Methylation Biomarkers for Non-Endoscopic Detection of Barrett’s Esophagus

    PubMed Central

    Moinova, Helen R.; LaFramboise, Thomas; Lutterbaugh, James D.; Chandar, Apoorva Krishna; Dumot, John; Faulx, Ashley; Brock, Wendy; De la Cruz Cabrera, Omar; Guda, Kishore; Barnholtz-Sloan, Jill S.; Iyer, Prasad G.; Canto, Marcia I.; Wang, Jean S.; Shaheen, Nicholas J.; Thota, Prashanti N.; Willis, Joseph E.; Chak, Amitabh; Markowitz, Sanford D.

    2018-01-01

    We report a biomarker-based non-endoscopic method for detecting Barrett’s esophagus (BE), based on detecting methylated DNAs retrieved via a swallowable balloon-based esophageal sampling device. BE is the precursor of, and a major recognized risk factor for, developing esophageal adenocarcinoma (EAC). Endoscopy, the current standard for BE detection, is not cost-effective for population screening. We performed genome-wide screening to ascertain regions targeted for recurrent aberrant cytosine methylation in BE, identifying high-frequency methylation within the CCNA1 locus. We tested CCNA1 DNA methylation as a BE biomarker in cytology brushings of the distal esophagus from 173 individuals with or without BE. CCNA1 DNA methylation demonstrated an area under the curve (AUC)=0.95 for discriminating BE-related metaplasia and neoplasia cases versus normal individuals, performing identically to methylation of VIM DNA, an established BE biomarker. When combined, the resulting two biomarker panel was 95% sensitive and 91% specific. These results were replicated in an independent validation cohort of 149 individuals, who were assayed using the same cutoff values for test positivity established in the training population. To progress toward non-endoscopic esophageal screening, we engineered a well-tolerated, swallowable, encapsulated balloon device able to selectively sample the distal esophagus within 5 minutes. In balloon samples from 86 individuals, tests of CCNA1 plus VIM DNA methylation detected BE metaplasia with 90.3% sensitivity and 91.7% specificity. Combining the balloon sampling device with molecular assays of CCNA1 plus VIM DNA methylation enables an efficient, well-tolerated, sensitive, and specific method of screening at-risk populations for BE. PMID:29343623

  12. Long-term outcomes and risk factors of biliary stent dysfunction after endoscopic double stenting for malignant biliary and duodenal obstructions.

    PubMed

    Matsumoto, Kazuyuki; Kato, Hironari; Tsutsumi, Koichiro; Mizukawa, Sho; Yabe, Syuntaro; Seki, Hiroyuki; Akimoto, Yutaka; Uchida, Daisuke; Tomoda, Takeshi; Yamamoto, Naoki; Horiguchi, Shigeru; Kuwaki, Kenji; Okada, Hiroyuki

    2017-07-01

    Few reports describe the endoscopic double-stenting procedure for malignant biliary and duodenal obstructions. We evaluated the clinical outcomes from double stenting, and analyzed the risk factors for biliary stent dysfunction following double stenting. Eighty-one patients who underwent endoscopic double stenting for malignant biliary and duodenal obstructions were retrospectively analyzed. We determined the stent dysfunction rate and the biliary stent dysfunction risk factors, and analyzed the endoscopic reintervention results. Overall survival time and survival time following double stenting were 365 (38-1673) days and 73 (20-954) days, respectively. After double stenting, the 3-month and 6-month duodenal stent dysfunction rates were 14% and 41%, respectively. Reintervention technical success rate was 100% (10/10), and mean gastric outlet obstruction scoring system scores improved from 0.7 to 2.4 points (P < 0.001). The 3-month and 6-month biliary stent dysfunction rates were 26% and 41%, respectively. The reintervention technical and clinical success rates were 95% (20/21) and 81% (17/21), respectively. Risk factors for biliary stent dysfunction following double stenting were events associated with duodenal stent dysfunction (odds ratio [OR], 11.1; 95% confidence interval [CI], 2.09-87.4; P = 0.0044) and the biliary stent end's location (OR, 6.93; 95% CI, 1.37-40.2; P = 0.0019). Some patients had stent dysfunction irrespective of the survival period after double stenting. Endoscopic reintervention was technically feasible and clinically effective even after double stenting. Duodenal stent dysfunction and biliary stent end's location were risk factors for biliary stent dysfunction. © 2017 Japan Gastroenterological Endoscopy Society.

  13. [Sialoendoscopy-assisted sialolithectomy for large parotid stones].

    PubMed

    Zhao, Jian; Zhang, Lei; Liu, Deng-gao; Zhang, Zu-yan; Yu, Guang-yan

    2014-02-18

    To explore the clinical application of endoscope-assisted operative retrieval of large parotid stones as a minimally invasive alternative. From January 2010 to April 2013, 6 patients (male: 5, female: 1, age from 30-62 years, and median age: 49.5 years)suffering from recurred swelling of parotid gland due to sialoliths were treated by endoscope-assisted parotid surgery in Peking University School and Hospital of Stomatology. All of the patients underwent clinical, ultrasonographic and cone-beam CT (CBCT) examinations to get the detailed information of the number, location and size of stones, which was recorded in the medical records. endoscope-assisted parotid surgery was performed under general anesthesia in all the 6 cases after the failure of basket or forcep retrieval firstly. During the operation, sialoendoscope was used to locate the stone exactly and then the calculus was exposed through a pre-auricular approach and released by incising the duct. The postoperative complications were recorded and observed during the follow-up periods. Preoperative radiological examinations showed that all of the sialoliths were near the hilum of parotid gland ducts in the 6 cases, which were 5-9 mm in diameter. All of the stones were removed successfully by endoscope-assisted operative retrieval. The incisions healed smoothly in all the 6 cases. There were no cases of facial nerve weakness, infection or salivary fistula. After a mean follow-up of 19 months (ranging from 6-36 months), 5 patients remained asymptomatic and 1 patient had mild obstructed or infective symptoms. The final results were satisfied. It is suggested that endoscope-assisted operative retrieval is a viable minimally invasive alternative to remove the large or recalcitrant parotid stones with a high successful rate and low complications.

  14. Instrumentation For The Surgical Application Of The Nd:YAG Laser

    NASA Astrophysics Data System (ADS)

    Frank, F.; Bailer, P.; Beck, O.; Bowering, R.; Hofstetter, A.

    1984-03-01

    The Nd:YAG laser has become a coagulation instrument, which has found acceptance in interdisciplinary surgery. The main contributors are its highly efficient coagulation capability in interaction with tissue and the fact that the Nd:YAG laser beam can be transmitted by means of a simple quartz-glass fiber. Appropriate systems and instruments for transmission and operation have been developed for the various applications in neurosurgery, pulmology, gastroenterology, urology, gynaecology and dermatology. Operation methods in open and endoscopic surgery under use of several hand held devices and flexible as well as rigid endoscopes are being demonstrated by clinical examples of application.

  15. Outcome of stenting in biliary and pancreatic benign and malignant diseases: A comprehensive review

    PubMed Central

    Mangiavillano, Benedetto; Pagano, Nico; Baron, Todd H; Luigiano, Carmelo

    2015-01-01

    Endoscopic stenting has become a widely method for the management of various malignant and benign pancreatico-biliary disorders. Biliary and pancreatic stents are devices made of plastic or metal used primarily to establish patency of an obstructed bile or pancreatic duct and may also be used to treat biliary or pancreatic leaks, pancreatic fluid collections and to prevent post-endoscopic retrograde cholangiopancreatography pancreatitis. In this review, relevant literature search and expert opinions have been used to evaluate the outcome of stenting in biliary and pancreatic benign and malignant diseases. PMID:26290631

  16. Development of Endoscopic Diagnosis and Treatment for Chronic Unilateral Hematuria: 35 Years Experience.

    PubMed

    Tanimoto, Ryuta; Kumon, Hiromi; Bagley, Demetrius H

    2017-04-01

    Chronic unilateral hematuria (CUH) is also called lateralizing essential hematuria, benign essential hematuria, and benign lateralizing hematuria, which was defined as intermittent or continuous gross hematuria that cannot be diagnosed with standard radiology and hematology studies, together with unilateral bloody efflux by cystoscopy. CUH is rare, but sometimes confused with malignancy or life-threatening hemorrhage. Therefore, it can cause considerable anxiety to not only patients but also urologists. For this study, we summarized articles about endoscopic diagnosis and treatment of CUH, and discussed the development of endourology for CUH. We searched articles related to CUH that were indexed in the PubMed database and published in English. Key terms used were "unilateral," "lateralizing," "chronic," "benign," and "idiopathic" hematuria. We found 15 pertinent articles reporting CUH. Endoscopically, CUH can be classified into three categories: discrete lesion, diffuse lesion, or no (unidentified) lesion. Currently, endoscopic techniques for CUH are similar to the techniques for upper tract urothelial carcinoma, using semi-rigid and flexible ureteroscopes with diathermy fulguration or laser ablation for treatment. The overall success rate of endoscopic treatment for CUH, defined as resolution of gross hematuria after treatment, was 93% (190/205). The recurrence rate, defined as recurrent gross hematuria after treatment, was 10% (19/189). Advancements in endoscopic devices and techniques have enabled more accurate and less invasive diagnosis and treatment of CUH. Once CUH is defined, flexible ureteroscopy is the diagnostic and therapeutic technique of choice.

  17. Cooperative laparoscopic endoscopic and hybrid laparoscopic surgery for upper gastrointestinal tumors: Current status

    PubMed Central

    Ntourakis, Dimitrios; Mavrogenis, Georgios

    2015-01-01

    AIM: To investigate the cooperative laparoscopic and endoscopic techniques used for the resection of upper gastrointestinal tumors. METHODS: A systematic research of the literature was performed in PubMed for English and French language articles about laparoscopic and endoscopic cooperative, combined, hybrid and rendezvous techniques. Only original studies using these techniques for the resection of early gastric cancer, benign tumors and gastrointestinal stromal tumors of the stomach and the duodenum were included. By excluding case series of less than 10 patients, 25 studies were identified. The study design, number of cases, tumor pathology size and location, the operative technique name, the endoscopy team and surgical team role, operative time, type of closure of visceral wall defect, blood loss, complications and length of hospital stay of these studies were evaluated. Additionally all cooperative techniques found were classified and are presented in a systematic approach. RESULTS: The studies identified were case series and retrospective cohort studies. A total of 706 patients were operated on with a cooperative technique. The tumors resected were only gastrointestinal stromal tumors (GIST) in 4 studies, GIST and various benign submucosal tumors in 22 studies, early gastric cancer (pT1a and pT1b) in 6 studies and early duodenal cancer in 1 study. There was important heterogeneity between the studies. The operative techniques identified were: laparoscopic assisted endoscopic resection, endoscopic assisted wedge resection, endoscopic assisted transgastric and intragastric surgery, laparoscopic endoscopic cooperative surgery (LECS), laparoscopic assisted endoscopic full thickness resection (LAEFR), clean non exposure technique and non-exposed endoscopic wall-inversion surgery (NEWS). Each technique is illustrated with the roles of the endoscopic and laparoscopic teams; the indications, characteristics and short term results are described. CONCLUSION: Along with the traditional cooperative techniques, new procedures like LECS, LAEFR and NEWS hold great promise for the future of minimally invasive oncologic procedures. PMID:26604655

  18. "TuNa-saving" endoscopic medial maxillectomy: a surgical technique for maxillary inverted papilloma.

    PubMed

    Pagella, Fabio; Pusateri, Alessandro; Matti, Elina; Avato, Irene; Zaccari, Dario; Emanuelli, Enzo; Volo, Tiziana; Cazzador, Diego; Citraro, Leonardo; Ricci, Giampiero; Tomacelli, Giovanni Leo

    2017-07-01

    The maxillary sinus is the most common site of sinonasal inverted papilloma. Endoscopic sinus surgery, in particular endoscopic medial maxillectomy, is currently the gold standard for treatment of maxillary sinus papilloma. Although a common technique, complications such as stenosis of the lacrimal pathway and consequent development of epiphora are still possible. To avoid these problems, we propose a modification of this surgical technique that preserves the head of the inferior turbinate and the nasolacrimal duct. A retrospective analysis was performed on patients treated for maxillary inverted papilloma in three tertiary medical centres between 2006 and 2014. Pedicle-oriented endoscopic surgery principles were applied and, in select cases where the tumour pedicle was located on the anterior wall, a modified endoscopic medial maxillectomy was carried out as described in this paper. From 2006 to 2014 a total of 84 patients were treated. A standard endoscopic medial maxillectomy was performed in 55 patients (65.4%), while the remaining 29 (34.6%) had a modified technique performed. Three recurrences (3/84; 3.6%) were observed after a minimum follow-up of 24 months. A new surgical approach for select cases of maxillary sinus inverted papilloma is proposed in this paper. In this technique, the endoscopic medial maxillectomy was performed while preserving the head of the inferior turbinate and the nasolacrimal duct ("TuNa-saving"). This technique allowed for good visualization of the maxillary sinus, good oncological control and a reduction in the rate of complications.

  19. Mobile locally operated detachable end-effector manipulator for endoscopic surgery.

    PubMed

    Kawai, Toshikazu; Shin, Myongyu; Nishizawa, Yuji; Horise, Yuki; Nishikawa, Atsushi; Nakamura, Tatsuo

    2015-02-01

    Local surgery is safer than remote surgery because emergencies can be more easily addressed. Although many locally operated surgical robots and devices have been developed, none can safely grasp organs and provide traction. A new manipulator with a detachable commercial forceps was developed that can act as a third arm for a surgeon situated in a sterile area near the patient. This mechanism can be disassembled into compact parts that enable mobile use. A mobile locally operated detachable end-effector manipulator (LODEM) was developed and tested. This device uses crank-slider and cable-rod mechanisms to achieve 5 degrees of freedom and an acting force of more than 5 N. The total mass is less than 15 kg. The positional accuracy and speed of the prototype device were evaluated while performing simulated in vivo surgery. The accuracy of the mobile LODEM was 0.4 mm, sufficient for handling organs. The manipulator could be assembled and disassembled in 8 min, making it highly mobile. The manipulator could successfully handle the target organs with the required level of dexterity during an in vivo laparoscopic surgical procedure. A mobile LODEM was designed that allows minimally invasive robotically assisted endoscopic surgery by a surgeon working near the patient. This device is highly promising for robotic surgery applications.

  20. Lymphovascular invasion in more than one-quarter of small rectal neuroendocrine tumors

    PubMed Central

    Kwon, Mi Jung; Kang, Ho Suk; Soh, Jae Seung; Lim, Hyun; Kim, Jong Hyeok; Park, Choong Kee; Park, Hye-Rim; Nam, Eun Sook

    2016-01-01

    AIM To identify the frequency, clinicopathological risk factors, and prognostic significance of lymphovascular invasion (LVI) in endoscopically resected small rectal neuroendocrine tumors (NETs). METHODS Between June 2005 and December 2015, 104 cases of endoscopically resected small (≤ 1 cm) rectal NET specimens at Hallym University Sacred Heart Hospital in Korea were retrospectively evaluated. We compared the detected rate of LVI in small rectal NET specimens by two methods: hematoxylin and eosin (H&E) and ancillary immunohistochemical staining (D2-40 and Elastica van Gieson); in addition, LVI detection rate difference between endoscopic procedures were also evaluated. Patient characteristics, prognosis and endoscopic resection results were reviewed by medical charts. RESULTS We observed LVI rates of 25.0% and 27.9% through H&E and ancillary immunohistochemical staining. The concordance rate between H&E and ancillary studies was 81.7% for detection of LVI, which showed statistically strong agreement between two methods (κ = 0.531, P < 0.001). Two endoscopic methods were studied, including endoscopic submucosal resection with a ligation device and endoscopic submucosal dissection, and no statistically significant difference in the LVI detection rate was detected between the two (26.3% and 26.8%, P = 0.955). LVI was associated with large tumor size (> 5 mm, P = 0.007), tumor grade 2 (P = 0.006). Among those factors, tumor grade 2 was the only independent predictive factor for the presence of LVI (HR = 4.195, 95%CI: 1.321-12.692, P = 0.015). No recurrence was observed over 28.8 mo regardless of the presence of LVI. CONCLUSION LVI may be present in a high percentage of small rectal NETs, which may not be associated with short-term prognosis. PMID:27895428

  1. Feasibility and Diagnostic Yield of Endoscopic Ultrasonography-Guided Fine Needle Biopsy With a New Core Biopsy Needle Device in Patients With Gastric Subepithelial Tumors

    PubMed Central

    Lee, Minju; Min, Byung-Hoon; Lee, Hyuk; Ahn, Sangjeong; Lee, Jun Haeng; Rhee, Poong-Lyul; Kim, Jae J.; Sohn, Tae Sung; Kim, Sung; Kim, Kyoung-Mee

    2015-01-01

    Abstract As treatment decisions for patients with gastric subepithelial tumors (SETs) largely depend on the histopathologic diagnosis, noninvasive and effective tissue acquisition methods are definitely required for proper management of gastric SETs. Recently, a new endoscopic ultrasonography-guided fine needle biopsy (EUS-FNB) device with ProCore reverse bevel technology was developed. We aimed to elucidate the feasibility and diagnostic yield of EUS-FNB with this new core biopsy needle device in patients with gastric SETs. A prospectively maintained database was retrospectively reviewed to identify consecutive patients who underwent EUS-FNB with a 22-gauge ProCore needle for gastric SETs 2 cm or larger. The main outcome measurement was the diagnostic yield of EUS-FNB. Procedure results were categorized into diagnostic, suggestive, or nondiagnostic. Of the 43 patients, needle punctures were successful in all cases irrespective of tumor location. EUS-FNB procedure results were diagnostic in 86.0%, suggestive in 4.7%, and nondiagnostic in 9.3% of cases, respectively. The diagnostic yield was the highest in fundus (100.0%), followed by body (89.5%), cardia (83.3%), and antrum (50.0%). All 18 patients with cardiac SET were finally diagnosed to have leiomyoma, and 16 patients with diagnostic or suggestive results avoided surgery. A heterogeneous echo pattern on EUS was found in 33.3% of cases with nondiagnostic or suggestive results and in 5.4% with diagnostic results. In multivariate analysis, no independent predictor of unsuccessful EUS-FNB with nondiagnostic or suggestive results was identified. Agreement between EUS-FNB and surgical pathology was 100% with respect to the diagnosis of gastrointestinal stromal tumor. However, there was a significant discrepancy in mitotic counts observed between the EUS-FNB and surgical specimens in patients with gastrointestinal stromal tumor. There were no significant procedure-related adverse events during and after the procedures. EUS-FNB with a 22G ProCore needle is a technically feasible, safe, and effective procedure for pathologic diagnosis of gastric SETs. This procedure can help refine surgical indications and facilitate a proper treatment decisions for gastric SETs, especially in the cardia. PMID:26448008

  2. Gastric Bezoar Treatment by Endoscopic Fragmentation in Combination with Pepsi-Cola® Administration.

    PubMed

    Iwamuro, Masaya; Yunoki, Naoko; Tomoda, Jun; Nakamura, Kazuhiro; Okada, Hiroyuki; Yamamoto, Kazuhide

    2015-07-10

    Although bezoar dissolution by Coca-Cola® has been described in case reports and case series, to the best of our knowledge, the usefulness of other cola products such as Pepsi-Cola® has never been reported in the English literature. An 86-year-old Taiwanese man was diagnosed with a gastric bezoar. Endoscopic fragmentation with a polypectomy snare was attempted twice but failed to remove the bezoar. Subsequently, 500 mL of Pepsi NEX Zero® was administered daily for 4 days via nasogastric tube. The bezoar was softened and successfully fragmented by the polypectomy snare and needle-knife devices on the third attempt. This report presents the first case of a gastric bezoar successfully treated by endoscopic fragmentation in combination with Pepsi-Cola® administration, suggesting the possible utility of cola beverages in bezoar treatment, regardless of product brands.

  3. Continuing use of antithrombotic medications for patients with bleeding gastroduodenal ulcer requiring endoscopic hemostasis: a case-control study.

    PubMed

    Kawasaki, Keisuke; Nakamura, Shotaro; Kurahara, Koichi; Nagasue, Tomohiro; Yanai, Shunichi; Harada, Akira; Yaita, Hiroki; Fuchigami, Tadahiko; Matsumoto, Takayuki

    2017-09-01

    The aim of this study was to compare clinical characteristics and outcomes of bleeding gastroduodenal ulcer between patients taking antithrombotic medications and those not taking antithrombotic medications. We performed a case-control study of 346 patients with endoscopically verified bleeding gastroduodenal ulcer, which included 173 cases taking antithrombotic medications throughout peri-bleeding period and 173 age- and sex-matched controls not taking antithrombotic medications. The cases showed less frequent Helicobacter pylori (H. pylori) infections (45.1% versus 60.7%, p = .005), more frequent duodenal location (31.8% versus 19.1%, p = .009), and more frequent rebleeding (13.9% versus 5.8%, p = .02) than the controls. Multivariate analysis revealed that duodenal location (odds ratio [OR] 3.01, 95% confidence interval [CI] 1.37-6.65) and use of antithrombotic medications (OR 2.47, 95% CI 1.13-5.77) were independent factors for rebleeding. However, there were no differences in clinical outcomes, including final successful endoscopic hemostasis, need for surgical intervention, and mortality between cases and controls. Thromboembolic events did not occur in any cases and controls during the periendoscopic period. Low prevalence of H. pylori infection, frequent duodenal location, and high rebleeding rate are characteristics of patients with bleeding gastroduodenal ulcer under antithrombotic medications. Continuation of antithrombotic medications can be accepted for bleeding gastroduodenal ulcer.

  4. Leiomyosarcoma of the stomach treated by endoscopic submucosal dissection.

    PubMed

    Sato, Takao; Akahoshi, Kazuya; Tomoeda, Naru; Kinoshita, Norikatsu; Kubokawa, Masaru; Yodoe, Kentaro; Hiraki, Yuka; Oya, Masafumi; Yamamoto, Hidetaka; Ihara, Eikichi

    2018-03-02

    There have been no reports of primary leiomyosarcoma of the stomach treated by endoscopic submucosal dissection (ESD). We report an extremely rare case of gastric leiomyosarcoma that was successfully treated by ESD. An asymptomatic 74-year-old female underwent esophagogastroduodenoscopy for screening in December 2013. A centrally depressed submucosal tumor 10 mm in diameter was detected at the posterior wall of the upper gastric body. Follow-up esophagogastroduodenoscopy conducted 5 months later showed that the tumor diameter had increased to 15 mm. Endoscopic ultrasound revealed a hypoechoic mass located in the second to the middle of the third layer. Endoscopic ultrasound-guided fine-needle aspiration demonstrated a myogenic tumor. The tumor was completely resected by ESD without complications. Immunohistopathological diagnosis of the resected specimen was gastric leiomyosarcoma derived from the muscularis mucosae, with negative lateral and vertical margins. No local recurrence or metastasis has been detected at 36 months after ESD. This is the first report of gastric leiomyosarcoma treated by ESD in the English language literature.

  5. Endoscopic modified medial maxillectomy for treatment of inverted papilloma originating from the maxillary sinus.

    PubMed

    Erbek, Selim S; Koycu, Alper; Buyuklu, Fuat

    2015-05-01

    Endoscopic approaches have become an alternative to external approaches in the treatment of sinonasal inverted papillomas (IPs) in recent years. The aim of this study was to analyze the outcomes of endoscopic modified medial maxillectomy preserving the nasolacrimal duct and the inferior turbinate in selected IP cases. Medical charts of patients diagnosed with IP originating from the maxillary sinus between July 2008 and August 2013 were reviewed. Eight patients who had undergone endoscopic modified medial maxillectomy were included in the study. Attachment of IP was located on the medial wall of the maxillary sinus in all cases. The nasolacrimal duct was preserved in all of the patients. The inferior turbinate was completely preserved in 5 patients, and the anterior part of the inferior turbinate was preserved in 3 patients. The mean follow-up period of the patients was 30.8 months (12-60  mo). None of the patients had recurrence or major complications. The postoperative complaints were minor hemorrhagic discharge and crusting for the first few weeks. Endoscopic modified medial maxillectomy preserving the nasolacrimal duct and the inferior turbinate provides good surgical and functional outcomes in selected IP cases.

  6. Endoscopic probe optics for spectrally encoded confocal microscopy.

    PubMed

    Kang, Dongkyun; Carruth, Robert W; Kim, Minkyu; Schlachter, Simon C; Shishkov, Milen; Woods, Kevin; Tabatabaei, Nima; Wu, Tao; Tearney, Guillermo J

    2013-01-01

    Spectrally encoded confocal microscopy (SECM) is a form of reflectance confocal microscopy that can achieve high imaging speeds using relatively simple probe optics. Previously, the feasibility of conducting large-area SECM imaging of the esophagus in bench top setups has been demonstrated. Challenges remain, however, in translating SECM into a clinically-useable device; the tissue imaging performance should be improved, and the probe size needs to be significantly reduced so that it can fit into luminal organs of interest. In this paper, we report the development of new SECM endoscopic probe optics that addresses these challenges. A custom water-immersion aspheric singlet (NA = 0.5) was developed and used as the objective lens. The water-immersion condition was used to reduce the spherical aberrations and specular reflection from the tissue surface, which enables cellular imaging of the tissue deep below the surface. A custom collimation lens and a small-size grating were used along with the custom aspheric singlet to reduce the probe size. A dual-clad fiber was used to provide both the single- and multi- mode detection modes. The SECM probe optics was made to be 5.85 mm in diameter and 30 mm in length, which is small enough for safe and comfortable endoscopic imaging of the gastrointestinal tract. The lateral resolution was 1.8 and 2.3 µm for the single- and multi- mode detection modes, respectively, and the axial resolution 11 and 17 µm. SECM images of the swine esophageal tissue demonstrated the capability of this device to enable the visualization of characteristic cellular structural features, including basal cell nuclei and papillae, down to the imaging depth of 260 µm. These results suggest that the new SECM endoscopic probe optics will be useful for imaging large areas of the esophagus at the cellular scale in vivo.

  7. Endoscope system with plasma flushing and coaxial round jet nozzle for off-pump cardiac surgery.

    PubMed

    Horiuchi, Tetsuya; Masamune, Ken; Iwase, Yuki; Ymashita, Hiromasa; Tsukihara, Hiroyuki; Motomura, Noboru; Ohta, Yuji; Dohi, Takeyoshi

    2011-07-01

    To develop a new endoscope for performing simple surgical tasks inside the blood-filled cardiac atrium/chamber, that is, "off-pump" cardiac surgeries. We developed the endoscope system with plasma flushing and coaxial round jet nozzle. The "plasma flushing" system was invented to observe the interior of the blood-filled heart by displacing blood cells in front of the endoscope tip. However, some areas could not be observed with simple flushing of the liquid because the flushed liquid mixed with blood. Further, a large amount of liquid had to be flushed, which posed a risk of cardiac damage caused by excess volume. Therefore, to safely capture high-resolution images of the interior of the heart, an endoscope with a coaxial round jet nozzle through which plasma is flushed has been developed. And to reduce the volume of flushed liquid, the synchronization system of heartbeat and the endoscope system with plasma flushing has been developed. We conducted an in vivo experiment to determine whether we could observe intracardiac tissues in swine without the use of a heart-lung machine. As a result, we successfully observed intracardiac tissues without using a heart-lung machine. By using a coaxial nozzle, we could even observe the tricuspid valve. Moreover, we were able to save up to 30% of the flushed liquid by replacing the original system with a synchronization system. And we evaluated the performance of the endoscope with the coaxial round jet nozzle by conducting fluid analysis and an in vitro experiment. We successfully observed intracardiac tissues without using a heart-lung machine. By using a coaxial nozzle, we could even observe the tricuspid valve. And by replacing an original system to a synchronization system, we were able to save up to 30% of the flushed liquid. As a follow-up study, we plan to create a surgical flexible device for valve disease that can grasp, staple, and repair cardiac valves by endoscopic visualization.

  8. Association of clinical signs with endoscopic findings in horses with nasopharyngeal cicatrix syndrome: 118 cases (2003-2008).

    PubMed

    Norman, Tracy E; Chaffin, M Keith; Bisset, Wesley T; Thompson, James A

    2012-03-15

    To characterize the associations between clinical signs of nasopharyngeal cicatrix syndrome (NCS) and endoscopic findings in horses. Retrospective, case-control study. 239 horses (118 case horses and 121 control horses). Medical records of horses that had an endoscopic evaluation of the upper airway performed between January 2003 and December 2008 were reviewed. Clinical signs and the appearance and anatomic locations of lesions identified during endoscopic evaluation were reviewed and recorded for each horse. The associations between clinical signs and endoscopic findings were evaluated by the use of a prospective logistic model that used a Bayesian method for inference and was implemented by a Markov chain Monte Carlo method. Nasal discharge was associated with acute inflammation of the pharynx and larynx. Exercise intolerance was associated with circumferential pharyngeal lesions. Respiratory noise was associated with chronic scarring of the pharynx, a combination of pharyngeal and laryngeal scarring, and circumferential scarring of the pharynx. Respiratory distress was associated with acute inflammation of all portions of the airway, especially when there was preexisting scarring and narrowing of the airway by ≥ 50%. Cough did not have any significant association with NCS, compared with results in control horses. Associations between the endoscopic appearance of NCS lesions and relevant clinical signs will help practitioners identify horses with NCS and allow them to select appropriate treatment.

  9. Endoscopic management of congenital esophageal stenosis.

    PubMed

    Romeo, Erminia; Foschia, Francesca; de Angelis, Paola; Caldaro, Tamara; Federici di Abriola, Giovanni; Gambitta, Rosaalba; Buoni, Simona; Torroni, Filippo; Pardi, Valerio; Dall'oglio, Luigi

    2011-05-01

    Congenital esophageal stenosis (CES) is a rare malformation. Endoscopic dilations represent a therapeutic option. This study retrospectively evaluated the efficacy and safety of a conservative treatment of CES. Patients diagnosed with CES since 1980 by a barium study or endoscopy were reviewed. Endoscopic ultrasonography (Olympus UM-3R-20-MHz radial miniprobe, Olympus Corporation, Tokyo, Japan), available from 2001, allowed for the differential diagnosis of tracheobronchial remnants (TBR) and fibromuscular hypertrophy (FMH) CES. All children underwent conservative treatment by endoscopic dilations (hydrostatic and Savary). Forty-seven patients (20 men) had CES. Fifteen were associated with esophageal atresia; and 8, with Down syndrome. Mean age at the diagnosis was 28.3 months (range, 1 day to 146 months). Symptoms were solid food refusal, regurgitation, vomiting, and dysphagia. Congenital esophageal stenosis was located in the distal esophagus. Endoscopic ultrasonography demonstrated TBR and FMH in 6 patients. One hundred forty-eight dilations in 47 patients were performed. The stenosis healed in 45 (95.7%). Complications were 5 (10.6%) esophageal perforations, hydrostatic (3/32, or 9.3%), and Savary (2/116, or 1.7%). At follow-up, 1 patient with FMH CES and 1 patient with TBR CES required operation for persistent dysphagia. The conservative treatment yielded positive outcomes in CES. Endoscopic ultrasonography allows for a correct diagnosis of TBR/FMH CES. A surgical approach should be reserved for CES not responsive to dilations. Copyright © 2011 Elsevier Inc. All rights reserved.

  10. Geometric estimation of intestinal contraction for motion tracking of video capsule endoscope

    NASA Astrophysics Data System (ADS)

    Mi, Liang; Bao, Guanqun; Pahlavan, Kaveh

    2014-03-01

    Wireless video capsule endoscope (VCE) provides a noninvasive method to examine the entire gastrointestinal (GI) tract, especially small intestine, where other endoscopic instruments can barely reach. VCE is able to continuously provide clear pictures in short fixed intervals, and as such researchers have attempted to use image processing methods to track the video capsule in order to locate the abnormalities inside the GI tract. To correctly estimate the speed of the motion of the endoscope capsule, the radius of the intestinal track must be known a priori. Physiological factors such as intestinal contraction, however, dynamically change the radius of the small intestine, which could bring large errors in speed estimation. In this paper, we are aiming to estimate the radius of the contracted intestinal track. First a geometric model is presented for estimating the radius of small intestine based on the black hole on endoscopic images. To validate our proposed model, a 3-dimentional virtual testbed that emulates the intestinal contraction is then introduced in details. After measuring the size of the black holes on the test images, we used our model to esimate the radius of the contracted intestinal track. Comparision between analytical results and the emulation model parameters has verified that our proposed method could preciously estimate the radius of the contracted small intestine based on endoscopic images.

  11. Unusual Association Between Spontaneous Lateral Sphenoid Encephalocele and Chiari Malformation Type I: Endoscopic Repair Through a Transpterygoid Approach.

    PubMed

    Starnoni, Daniele; Daniel, Roy Thomas; George, Mercy; Messerer, Mahmoud

    2017-01-01

    Spontaneous meningoencephaloceles of the lateral sphenoid sinus are rare entities, and their peculiar location represents a surgical challenge due to the importance of a wide exposure and skull base reconstruction. They are thought to arise from the congenital base defect of the lateral sphenoid or in some cases have been postulated to represent a rare manifestation of altered cerebrospinal fluid (CSF) dynamics. We report the first case in the literature of a Chiari malformation type I (CMI) and a lateral sphenoid encephalocele, revising the theoretic etiology and surgical technique of endoscopic repair. A 50-year-old woman with a surgical history of symptomatic CMI presented with episodes of spontaneous CSF rhinorrhea. Radiologic investigations revealed a left mesial temporal encephalocele herniating into the lateral recess of the sphenoid sinus and radiologic features of altered CSF dynamics, which may have played an etiologic role. An endoscopic transpterygoid excision of the encephalocele and multilayer skull base repair were performed. The association of spontaneous lateral sphenoid encephaloceles with CMI is distinctly unusual. Predisposing factors and disruption of CSF dynamics may play a major role in the development of these rare complications in patients with CMI. Because of their distinct location, transethmoid or transpterygoid endoscopic approaches represent an excellent surgical technique to treat these lesions thanks to their wide and direct visualization of the entire skull base defect following the encephalocele excision, allowing an adequate multilayer repair and lateral sphenoid recess occlusion. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Feasibility of pure EFTR using an innovative new endoscopic suturing device: the Double-arm-bar Suturing System (with video).

    PubMed

    Mori, Hirohito; Kobara, Hideki; Fujihara, Shintaro; Nishiyama, Noriko; Rafiq, Kazi; Oryu, Makoto; Fujiwara, Masao; Suzuki, Yasuyuki; Masaki, Tsutomu

    2014-02-01

    Endoscopic full-thickness resection (EFTR) requires a reliable full-thickness suturing device and an endoscopic counter-traction device to prevent the collapse of the digestive tract. The present study aimed to assess the reliability of newly developed flexible endoscopy suturing devices and the feasibility of pure EFTR. A total of 30 EFTRs were performed and allocated to three groups (N = 10 for each group). The full-thickness sutures were placed using over-the-scope clips (OTSCs), hand-sewn sutures, or the Double-arm-bar Suturing System (DBSS). Air leak tests were conducted in the three groups. The times required for the placement of one OTSC suture and single-stitch simple interrupted sutures (hand-sewn and DBSS sutures, respectively) were also compared. All 30 full-thickness sutures were completely and successfully placed. Regarding the air leak tests, the Mann-Whitney U test showed significant differences between OTSC and hand-sewn sutures (p = 0.003). There was also a significant difference between OTSC and DBSS sutures (p = 0.023). There was no significant difference between hand-sewn and DBSS sutures (p = 0.542). A significant difference was found in the suture time for single-stitch simple interrupted sutures among the OTSC, hand-sewn, and DBSS sutures. The Mann-Whitney U test revealed a significant difference between OTSC and hand-sewn sutures (p = 0.0001). There was no significant difference between OTSC and DBSS sutures (p = 0.533), while a significant difference was found between hand-sewn and DBSS sutures (p = 0.0001). Pure EFTR is feasible if the mechanical counter traction system is used to expand a small operative field and DBSS is used to make full-thickness sutures. The high safety of full-thickness resection and full-thickness suturing allows for clinical applications of this method.

  13. Esophageal stent fixation with endoscopic suturing device improves clinical outcomes and reduces complications in patients with locally advanced esophageal cancer prior to neoadjuvant therapy: a large multicenter experience.

    PubMed

    Yang, Juliana; Siddiqui, Ali A; Kowalski, Thomas E; Loren, David E; Khalid, Ammara; Soomro, Ayesha; Mazhar, Syed M; Rosé, Julian; Isby, Laura; Kahaleh, Michel; Kalra, Ankush; Sarkisian, Alex M; Kumta, Nikhil A; Nieto, Jose; Sharaiha, Reem Z

    2017-03-01

    Endoscopic placement of fully covered self-expanding metal stents (FCSEMS) to treat malignant dysphagia in patients with esophageal cancer significantly improves dysphagia; however, these stents have a high migration rate. To determine whether FCSEMS fixation using an endoscopic suturing device treated malignant dysphagia and prevented stent migration in patients with locally advanced esophageal cancer receiving neoadjuvant therapy when compared to patients with FCSEMS placement alone. A review of patients with locally advanced esophageal cancer who underwent FCSEMS placement at 3 centers was performed. Patients were divided into two groups: Group A (n = 26) was composed of patients who underwent FCSEMS placement with suture placement, and Group B (n = 67) was composed of patients with FCSEMS placement alone. There were no significant differences between Groups A and B in demographics, and tumor characteristics. The technical success rate for stent placement was 100 %. There was no difference between Groups A and B in the median stent diameter and stent lengths. Mean dysphagia score obtained at 1 week after stent placement had improved significantly from baseline (2.4 and 1, respectively, p < 0.001). Patients had a median follow-up of 4 months. Immediate adverse events were mild chest discomfort in 4 patients in Group A and 2 patients in Group B (p = 0.05), and significant acid reflux in 3 patient in Group A compared to 2 patients in Group B (p = 0.1). The stent migration rate was significantly lower in Group A compared to compared to Group B (7.7 vs 26.9 %, respectively, p = 0.004). There was a delayed perforation in 1 patient and 1 death due to aspiration pneumonia in Group B. Fixation of esophageal FCSEMSs by using an endoscopic suturing device in patients receiving neoadjuvant therapy was shown to be feasible, safe, and relatively effective at preventing stent migration compared to those who had stent placed alone.

  14. Minimally Invasive Surgical Device for Precise Application of Bioadhesives to Prevent iPPROM.

    PubMed

    Devaud, Yannick Robert; Züger, Silvia; Zimmermann, Roland; Ehrbar, Martin; Ochsenbein-Kölble, Nicole

    2018-06-19

    The benefits of endoscopic fetal surgery are deteriorated by the high risk of iatrogenic preterm prelabor rupture of fetal membranes (iPPROM). While previous studies have reported good sealing candidates to prevent membrane rupture, the delivery of these materials to the location of membrane puncture remains unsolved. We describe an approach to apply sealing materials onto the amnion through the fetoscopy port. We developed a device composed of an umbrella-shaped polyester coated nitinol mesh and an applicator. The spontaneously unfolding umbrella is pushed through the port, pulled against the amnion, and glued onto the amnion defect site. We tested the adhesion strength of multiple glues and tested the feasibility and reproducibility of this fetal membrane sealing approach in an ex vivo model. The umbrella unfolded and was well positioned in all tests (n = 18). When applied via the fetoscopy port, umbrellas were successfully glued onto the fetal membrane, and all of them completely covered the defect (n = 5). The mean time needed for the whole procedure was 3 min. This study is a proof of concept presenting a potential future solution for the precise local application of bioadhesives for the prevention of iPPROM. © 2018 S. Karger AG, Basel.

  15. Endoscopic Sinus Surgery

    MedlinePlus

    ... and pituitary gland for neurosurgeons, or to the orbits (eye sockets) for certain ophthalmology procedures. Each individual ... that the sinuses are located next to the orbits (eye sockets) and directly beneath the bottom of ...

  16. Efficacy of Precut Endoscopic Mucosal Resection for Treatment of Rectal Neuroendocrine Tumors

    PubMed Central

    So, Hoonsub; Yoo, Su Hyun; Han, Seungbong; Kim, Gwang-un; Seo, Myeongsook; Hwang, Sung Wook; Yang, Dong-Hoon; Byeon, Jeong-Sik

    2017-01-01

    Background/Aims Endoscopic resection is the first-line treatment for rectal neuroendocrine tumors (NETs) measuring <1 cm and those between 1 and 2 cm in size. However, conventional endoscopic resection cannot achieve complete resection in all cases. We aimed to analyze clinical outcomes of precut endoscopic mucosal resection (EMR-P) used for the management of rectal NET. Methods EMR-P was used to treat rectal NET in 72 patients at a single tertiary center between 2011 and 2015. Both, circumferential precutting and EMR were performed with the same snare device in all patients. Demographics, procedural details, and histopathological features were reviewed for all cases. Results Mean size of the tumor measured endoscopically was 6.8±2.8 mm. En bloc and complete resection was achieved in 71 (98.6%) and 67 patients (93.1%), respectively. The mean time required for resection was 9.0±5.6 min. Immediate and delayed bleeding developed in six (8.3%) and 4 patients (5.6%), respectively. Immediate bleeding observed during EMR-P was associated with the risk of delayed bleeding. Conclusions Both, the en bloc and complete resection rates of EMR-P in the treatment of rectal NETs using the same snare for precutting and EMR were noted to be high. The procedure was short and safe. EMR-P may be a good treatment choice for the management of rectal NETs. PMID:29020763

  17. Improving patient and user safety during endoscopic investigation of the pancreatic and biliary ducts

    NASA Astrophysics Data System (ADS)

    Chandler, John E.; Melville, C. David; Lee, Cameron M.; Saunders, Michael D.; Burkhardt, Matthew R.; Seibel, Eric J.

    2011-03-01

    Endoscopic investigation of the main pancreatic duct and biliary ducts is called endoscopic retrograde cholangiopancreatography (ERCP), and carries a risk of pancreatitis for the patient. During ERCP, a metal guidewire is inserted into the pancreatobiliary duct from a side-viewing large endoscope within the duodenum. To verify correct placement of the ERCP guidewire, an injection of radiopaque dye is required for fluoroscopic imaging, which exposes the patient and clinical team to x-ray radiation. A safer and more effective means to access the pancreatobiliary system can use direct optical imaging, although the endoscope diameter and stiffness will be significantly larger than a guidewire's. To quantify this invasiveness before human testing, a synthetic force-sensing pancreas was fabricated and attached to an ERCP training model. The invasiveness of a new, 1.7-mm diameter, steerable scanning fiber endoscope (SFE) was compared to the standard ERCP guidewire of 0.89-mm (0.035") diameter that is not steerable. Although twice as large and significantly stiffer than the ERCP guidewire, the SFE generated lower or significantly less average force during insertion at all 4 sensor locations (P<0.05) within the main pancreatic duct. Therefore, the addition of steering and forward visualization at the tip of the endoscope reduced the invasiveness of the in vitro ERCP procedure. Since fluoroscopy is not required, risks associated with dye injection and x-ray exposure can be eliminated when using direct optical visualization. Finally, the SFE provides wide-field high resolution imaging for image-guided interventions, laser-based fluorescence biomarker imaging, and spot spectral analysis for future optical biopsy.

  18. Large beam deflection using cascaded prism array

    NASA Astrophysics Data System (ADS)

    Wang, Wei-Chih; Tsui, Chi-Leung

    2012-04-01

    Endoscopes have been utilize in the medical field to observe the internals of the human body to assist the diagnosis of diseases, such as breathing disorders, internal bleeding, stomach ulcers, and urinary tract infections. Endoscopy is also utilized in the procedure of biopsy for the diagnosis of cancer. Conventional endoscopes suffer from the compromise between overall size and image quality due to the required size of the sensor for acceptable image quality. To overcome the size constraint while maintaining the capture image quality, we propose an electro-optic beam steering device based on thermal-plastic polymer, which has a small foot-print (~5mmx5mm), and can be easily fabricated using conventional hot-embossing and micro-fabrication techniques. The proposed device can be implemented as an imaging device inside endoscopes to allow reduction in the overall system size. In our previous work, a single prism design has been used to amplify the deflection generated by the index change of the thermal-plastic polymer when a voltage is applied; it yields a result of 5.6° deflection. To further amplify the deflection, a new design utilizing a cascading three-prism array has been implemented and a deflection angle to 29.2° is observed. The new design amplifies the beam deflection, while keeping the advantage of simple fabrication made possible by thermal-plastic polymer. Also, a photo-resist based collimator lens array has been added to reduce and provide collimation of the beam for high quality imaging purposes. The collimator is able to collimate the exiting beam at 4 μm diameter for up to 25mm, which potentially allows high resolution image capturing.

  19. Advanced methods for controlling untethered magnetic devices using rotating magnetic fields

    NASA Astrophysics Data System (ADS)

    Mahoney, Arthur W., Jr.

    This dissertation presents results documenting advancements on the control of untethered magnetic devices, such as magnetic "microrobots" and magnetically actuated capsule endoscopes, motivated by problems in minimally invasive medicine. This dissertation focuses on applying rotating magnetic fields for magnetic manipulation. The contributions include advancements in the way that helical microswimmers (devices that mimic the propulsion of bacterial flagella) are controlled in the presence of gravitational forces, advancements in ways that groups of untethered magnetic devices can be differentiated and semi-independently controlled, advancements in the way that untethered magnetic device can be controlled with a single rotating permanent magnet, and an improved understanding in the nature of the magnetic force applied to an untethered device by a rotating magnet.

  20. Transforaminal Endoscopic Decompression for Foot Drop Twelve Years After Lumbar Total Disc Replacment: Technical Note.

    PubMed

    Telfeian, Albert E; Oyelese, Adetokunbo; Fridley, Jared; Gokaslan, Ziya L

    2018-05-19

    Lumbar total disc replacement (LTDR) is considered for the treatment of lumbar degenerative disc disease with the hope that by preserving motion the long-term fusion complication of adjacent segment disease can be avoided. The complications of LTDR can be divided into approach-related and long-term complications. Very little has been described about the complications and treatment for complications more than 10 years after the device has been implanted. Here we describe a tranforaminal endoscopic discectomy procedure for a patient presenting with foot drop twelve years after a L5-S1 total disc replacement. Copyright © 2018. Published by Elsevier Inc.

  1. In vivo imaging in the oral cavity by endoscopic optical coherence tomography.

    PubMed

    Walther, Julia; Schnabel, Christian; Tetschke, Florian; Rosenauer, Tobias; Golde, Jonas; Ebert, Nadja; Baumann, Michael; Hannig, Christian; Koch, Edmund

    2018-03-01

    The common way to diagnose hard and soft tissue irregularities in the oral cavity is initially the visual inspection by an experienced dentist followed by further medical examinations, such as radiological imaging and/or histopathological investigation. For the diagnosis of oral hard and soft tissues, the detection of early transformations is mostly hampered by poor visual access, low specificity of the diagnosis techniques, and/or limited feasibility of frequent screenings. Therefore, optical noninvasive diagnosis of oral tissue is promising to improve the accuracy of oral screening. Considering this demand, a rigid handheld endoscopic scanner was developed for optical coherence tomography (OCT). The novelty is the usage of a commercially near-infrared endoscope with fitting optics in combination with an established spectral-domain OCT system of our workgroup. By reaching a high spatial resolution, in vivo images of anterior and especially posterior dental and mucosal tissues were obtained from the oral cavity of two volunteers. The convincing image quality of the endoscopic OCT device is particularly obvious for the imaging of different regions of the human soft palate with highly scattering fibrous layer and capillary network within the lamina propria. (2018) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).

  2. Averaged subtracted polarization imaging for endoscopic diagnostics of surface microstructures on translucent mucosae

    NASA Astrophysics Data System (ADS)

    Kanamori, Katsuhiro

    2016-07-01

    An endoscopic image processing technique for enhancing the appearance of microstructures on translucent mucosae is described. This technique employs two pairs of co- and cross-polarization images under two different linearly polarized lights, from which the averaged subtracted polarization image (AVSPI) is calculated. Experiments were then conducted using an acrylic phantom and excised porcine stomach tissue using a manual experimental setup with ring-type lighting, two rotating polarizers, and a color camera; better results were achieved with the proposed method than with conventional color intensity image processing. An objective evaluation method that uses texture analysis was developed and used to evaluate the enhanced microstructure images. This paper introduces two types of online, rigid-type, polarimetric endoscopic implementations using a polarized ring-shaped LED and a polarimetric camera. The first type uses a beam-splitter-type color polarimetric camera, and the second uses a single-chip monochrome polarimetric camera. Microstructures on the mucosa surface were enhanced robustly with these online endoscopes regardless of the difference in the extinction ratio of each device. These results show that polarimetric endoscopy using AVSPI is both effective and practical for hardware implementation.

  3. Measurement of motion detection of wireless capsule endoscope inside large intestine.

    PubMed

    Zhou, Mingda; Bao, Guanqun; Pahlavan, Kaveh

    2014-01-01

    Wireless Capsule Endoscope (WCE) provides a noninvasive way to inspect the entire Gastrointestinal (GI) tract, including large intestine, where intestinal diseases most likely occur. As a critical component of capsule endoscopic examination, physicians need to know the precise position of the endoscopic capsule in order to identify the position of detected intestinal diseases. Knowing how the capsule moves inside the large intestine would greatly complement the existing wireless localization systems by providing the motion information. Since the most recently released WCE can take up to 6 frames per second, it's possible to estimate the movement of the capsule by processing the successive image sequence. In this paper, a computer vision based approach without utilizing any external device is proposed to estimate the motion of WCE inside the large intestine. The proposed approach estimate the displacement and rotation of the capsule by calculating entropy and mutual information between frames using Fibonacci method. The obtained results of this approach show its stability and better performance over other existing approaches of motion measurements. Meanwhile, findings of this paper lay a foundation for motion pattern of WCEs inside the large intestine, which will benefit other medical applications.

  4. Colonoscopic full-thickness resection using an over-the-scope device: a prospective multicentre study in various indications.

    PubMed

    Schmidt, Arthur; Beyna, Torsten; Schumacher, Brigitte; Meining, Alexander; Richter-Schrag, Hans-Juergen; Messmann, Helmut; Neuhaus, Horst; Albers, David; Birk, Michael; Thimme, Robert; Probst, Andreas; Faehndrich, Martin; Frieling, Thomas; Goetz, Martin; Riecken, Bettina; Caca, Karel

    2017-08-10

    Endoscopic full-thickness resection (EFTR) is a novel treatment of colorectal lesions not amenable to conventional endoscopic resection. The aim of this prospective multicentre study was to assess the efficacy and safety of the full-thickness resection device. 181 patients were recruited in 9 centres with the indication of difficult adenomas (non-lifting and/or at difficult locations), early cancers and subepithelial tumours (SET). Primary endpoint was complete en bloc and R0 resection. EFTR was technically successful in 89.5%, R0 resection rate was 76.9%. In 127 patients with difficult adenomas and benign histology, R0 resection rate was 77.7%. In 14 cases, lesions harboured unsuspected cancer, another 15 lesions were primarily known as cancers. Of these 29 cases, R0 resection was achieved in 72.4%; 8 further cases had deep submucosal infiltration >1000 µm. Therefore, curative resection could only be achieved in 13/29 (44.8%). In the subgroup with SET (n=23), R0 resection rate was 87.0%. In general, R0 resection rate was higher with lesions ≤2 cm vs >2 cm (81.2% vs 58.1%, p=0.0038). Adverse event rate was 9.9% with a 2.2% rate of emergency surgery. Three-month follow-up was available from 154 cases and recurrent/residual tumour was evident in 15.3%. EFTR has a reasonable technical efficacy especially in lesions ≤2 cm with acceptable complication rates. Curative resection rate for early cancers was too low to recommend its primary use in this indication. Further comparative studies have to show the clinical value and long-term outcome of EFTR in benign colorectal lesions. NCT02362126; Results. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  5. Management of chronic pancreatitis complicated with a bleeding pseudoaneurysm.

    PubMed

    Chiang, Kun-Chun; Chen, Tsung-Hsing; Hsu, Jun-Te

    2014-11-21

    Chronic pancreatitis is an ongoing disease characterized by persistent inflammation of pancreatic tissues. With disease progression, patients with chronic pancreatitis may develop troublesome complications in addition to exocrine and endocrine pancreatic functional loss. Among them, a pseudoaneurysm, mainly induced by digestive enzyme erosion of vessels in proximity to the pancreas, is a rare and life-threatening complication if bleeding of the pseudoaneurysm occurs. At present, no prospective randomized trials have investigated the therapeutic strategy for this rare but critical situation. The role of arterial embolization, the timing of surgical intervention and even surgical procedures are still controversial. In this review, we suggest that dynamic abdominal computed tomography and angiography should be performed first to localize the bleeders and to evaluate the associated complications such as pseudocyst formation, followed by arterial embolization to stop the bleeding and to achieve early stabilization of the patient's condition. With advances and improvements in endoscopic devices and techniques, therapeutic endoscopy for pancreatic pseudocysts is technically feasible, safe and effective. Surgical intervention is recommended for a bleeding pseudoaneurysm in patients with chronic pancreatitis who are in an unstable condition, for those in whom arterial embolization of the bleeding pseudoaneurysm fails, and when endoscopic management of the pseudocyst is unsuccessful. If a bleeding pseudoaneurysm is located over the tail of the pancreas, resection is a preferential procedure, whereas if the lesion is situated over the head or body of the pancreas, relatively conservative surgical procedures are recommended.

  6. Endoscopic partial medial maxillectomy with mucosal flap for maxillary sinus mucoceles.

    PubMed

    Durr, Megan L; Goldberg, Andrew N

    2014-01-01

    To describe a technique of endoscopic medial maxillectomy with mucosal flap for postoperative maxillary sinus mucoceles and to present a case series of subjects who underwent this procedure. This case series includes four subjects with postoperative maxillary sinus mucoceles who underwent resection via endoscopic partial medial maxillectomy with a mucosal flap. We will discuss the clinical presentation, imaging characteristics, operative details, and outcomes. Four subjects are included in this study. The average age at the time of medial maxillectomy was 52 years (range 35-65 years). Three subjects (75%) were female. One subject (25%) had bilateral postoperative maxillary sinus mucoceles. Two subjects (50%) had unilateral right sided mucoceles, and the remaining subject had a unilateral left sided mucocele. All subjects had a history of multiple sinus procedures for chronic sinusitis including Caldwell-Luc procedures ipsilateral to the postoperative mucocele. All subjects underwent endoscopic medial maxillectomy without complication and were symptom free at the last follow up appointment, average 24 months (range 3-71 months) after medial maxillectomy. For postoperative maxillary sinus mucoceles in locations that are difficult to access via the middle meatus antrostomy, we recommend endoscopic medial maxillectomy with mucosal flap. Our preliminary experience with four subjects demonstrates complete resolution of symptoms after this procedure. Copyright © 2014 Elsevier Inc. All rights reserved.

  7. Expanded Endonasal Endoscopic Approach for Resection of an Infrasellar Craniopharyngioma.

    PubMed

    Abou-Al-Shaar, Hussam; Blitz, Ari M; Rodriguez, Fausto J; Ishii, Masaru; Gallia, Gary L

    2016-11-01

    Craniopharyngiomas are uncommon benign locally aggressive epithelial tumors mostly located in the sellar and suprasellar regions. An infrasellar origin of these tumors is rare. The authors report a 22-year-old male patient with a purely infrasellar adamantinomatous craniopharyngioma centered in the nasopharynx with extension into the posterior nasal septum, sphenoid sinus, and clivus. Gross total resection was achieved using an expanded endonasal endoscopic transethmoidal, transsphenoidal, transpterygoid, and transclival approach. Follow-up at one year demonstrated no evidence of disease recurrence. Infrasellar craniopharyngioma should be included in the differential diagnosis of sinonasal masses even in the absence of sellar extension. Expanded endonasal endoscopic approaches provide excellent access to and visualization of such lesions and may obviate the need for postoperative radiotherapy when gross total resection is achieved. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Retrospective analysis of management of ingested foreign bodies and food impactions in emergency endoscopic setting in adults.

    PubMed

    Geraci, Girolamo; Sciume', Carmelo; Di Carlo, Giovanni; Picciurro, Antonino; Modica, Giuseppe

    2016-11-04

    Ingestion of foreign bodies and food impaction represent the second most common endoscopic emergency after bleeding. The aim of this paper is to report the management and the outcomes in 67 patients admitted for suspected ingestion of foreign body between December 2012 and December 2014. This retrospective study was conducted at Palermo University Hospitals, Italy, over a 2-year period. We reviewed patients' database (age, sex, type of foreign body and its anatomical location, treatments, and outcomes as complications, success rates, and mortalities). Foreign bodies were found in all of our 67 patients. Almost all were found in the stomach and lower esophagus (77 %). The types of foreign body were very different, but they were chiefly meat boluses, fishbones or cartilages, button battery and dental prostheses. In all patients it was possible to endoscopically remove the foreign body. Complications related to the endoscopic procedure were unfrequent (about 7 %) and have been treated conservatively. 5.9 % of patients had previous esophageal or laryngeal surgery, and 8.9 % had an underlying esophageal disease, such as a narrowing, dismotility or achalasia. Our experience with foreign bodies and food impaction emphasizes the importance of endoscopic approach and removal, simple and secure when performed by experienced hands and under conscious sedation in most cases. High success rates, lower incidence of minor complications, reduction of the need of surgery and reduced hospitalization time are the strengths of the endoscopic approach.

  9. Oesophageal foreign bodies in dogs: factors affecting success of endoscopic retrieval.

    PubMed

    Juvet, Florence; Pinilla, Manuel; Shiel, Robert E; Mooney, Carmel T

    2010-03-01

    Oesophageal foreign bodies are common in dogs. Endoscopic removal is a viable treatment option but few studies have assessed the clinical and radiographic features that would be useful in decision-making and prognosis.Dogs (n = 44) with oesophageal foreign bodies presented to the University Veterinary Hospital were assessed. Terriers and West Highland White Terriers were significantly overrepresented (p < 0.0001) and in those breeds the foreign body was significantly (p < 0.0001) more likely to be located caudal to the heart base. The majority (88.6%) of foreign bodies were bones or bone fragments.Group 1 (n = 30) included animals where endoscopic removal was successful and Group 2 (n = 14) animals where it was unsuccessful or not attempted because of evidence of oesophageal rupture. There was no statistically significant difference in age, sex, body weight, type, location and size of foreign body, recovery rate, short-term complications and long-term outcome between the two groups. Duration of signs prior to presentation and time to spontaneous oral feeding were significantly longer (p < 0.01 in each case) in Group 2 (five days and 120 hours, respectively) compared to Group 1 (2 days and 24 hours, respectively). Mortality was 11.1%. Long-term follow-up of 29 dogs suggested oesophageal stricture formation manageable by feeding alone in seven (24.1%) cases.Terriers appear predisposed to oesophageal foreign bodies. Success of endoscopic removal is adversely affected by duration of signs prior to presentation. Surgical removal negatively influences time to recovery. Stricture formation appears to be a relatively common complication and alternate measures for its prevention should be sought.

  10. Oesophageal foreign bodies in dogs: factors affecting success of endoscopic retrieval

    PubMed Central

    2010-01-01

    Oesophageal foreign bodies are common in dogs. Endoscopic removal is a viable treatment option but few studies have assessed the clinical and radiographic features that would be useful in decision-making and prognosis. Dogs (n = 44) with oesophageal foreign bodies presented to the University Veterinary Hospital were assessed. Terriers and West Highland White Terriers were significantly overrepresented (p < 0.0001) and in those breeds the foreign body was significantly (p < 0.0001) more likely to be located caudal to the heart base. The majority (88.6%) of foreign bodies were bones or bone fragments. Group 1 (n = 30) included animals where endoscopic removal was successful and Group 2 (n = 14) animals where it was unsuccessful or not attempted because of evidence of oesophageal rupture. There was no statistically significant difference in age, sex, body weight, type, location and size of foreign body, recovery rate, short-term complications and long-term outcome between the two groups. Duration of signs prior to presentation and time to spontaneous oral feeding were significantly longer (p < 0.01 in each case) in Group 2 (five days and 120 hours, respectively) compared to Group 1 (2 days and 24 hours, respectively). Mortality was 11.1%. Long-term follow-up of 29 dogs suggested oesophageal stricture formation manageable by feeding alone in seven (24.1%) cases. Terriers appear predisposed to oesophageal foreign bodies. Success of endoscopic removal is adversely affected by duration of signs prior to presentation. Surgical removal negatively influences time to recovery. Stricture formation appears to be a relatively common complication and alternate measures for its prevention should be sought. PMID:21851744

  11. Location of colorectal cancer: colonoscopy versus surgery. Yield of colonoscopy in predicting actual location.

    PubMed

    Blum-Guzman, Juan Pablo; Wanderley de Melo, Silvio

    2017-07-01

     Recent studies suggest that differences in biological characteristics and risk factors across cancer site within the colon and rectum may translate to differences in survival. It can be challenging at times to determine the precise anatomical location of a lesion with a luminal view during colonoscopy. The aim of this study is to determine if there is a significant difference between the location of colorectal cancers described by gastroenterologists in colonoscopies and the actual anatomical location noted on operative and pathology reports after colon surgery.  A single-center retrospective analysis of colonoscopies of patient with reported colonic masses from January 2005 to April 2014 (n = 380) was carried. Assessed data included demography, operative and pathology reports. Findings were compared: between the location of colorectal cancers described by gastroenterologists in colonoscopies and the actual anatomical location noted on operative reports or pathology samples.  We identified 380 colonic masses, 158 were confirmed adenocarcinomas. Of these 123 underwent surgical resection, 27 had to be excluded since no specific location was reported on their operative or pathology report. An absolute difference between endoscopic and surgical location was found in 32 cases (33 %). Of these, 22 (23 %) differed by 1 colonic segment, 8 (8 %) differed by 2 colonic segments and 2 (2 %) differed by 3 colonic segments.  There is a significant difference between the location of colorectal cancers reported by gastroenterologists during endoscopy and the actual anatomical location noted on operative or pathology reports after colon surgery. Endoscopic tattooing should be used when faced with any luminal lesions of interest.

  12. Cancer emerging from the recurrence of sessile serrated adenoma/polyp resected endoscopically 5 years ago.

    PubMed

    Chino, A; Nagayama, S; Ishikawa, H; Morishige, K; Kishihara, T; Arai, M; Sugiura, Y; Motoi, N; Yamamoto, N; Tamegai, Y; Igarashi, M

    2016-01-01

    Since the serrated neoplastic pathway has been regarded as an important pathway of colorectal carcinogenesis, few reports have been published on clinical cases of cancer derived from sessile serrated adenoma/polyp, especially on recurrence after resected sessile serrated adenoma/polyp. An elderly woman underwent endoscopic mucosal resection of a flat elevated lesion, 30 mm in diameter, in the ascending colon; the histopathological diagnosis at that time was a hyperplastic polyp, now known as sessile serrated adenoma/polyp. Five years later, cancer due to the malignant transformation of the sessile serrated adenoma/polyp was detected at the same site. The endoscopic diagnosis was a deep invasive carcinoma with a remnant sessile serrated adenoma/polyp component. The carcinoma was surgically removed, and the pathological diagnosis was an adenocarcinoma with sessile serrated adenoma/polyp, which invaded the muscularis propria. The surgically removed lesion did not have a B-RAF mutation in either the sessile serrated adenoma/polyp or the carcinoma; moreover, the initial endoscopically resected lesion also did not have a B-RAF mutation. Immunohistochemistry confirmed negative MLH1 protein expression in only the cancer cells. Lynch syndrome was not detected on genomic examination. The lesion was considered to be a cancer derived from sessile serrated adenoma/polyp recurrence after endoscopic resection, because both the surgically and endoscopically resected lesions were detected at the same location and had similar pathological characteristics, with a serrated structure and low-grade atypia. Furthermore, both lesions had a rare diagnosis of a sessile serrated adenoma/polyp without B-RAF mutation. This report highlights the need for the follow-up colonoscopy after endoscopic resection and rethinking our resection procedures to improve treatment. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  13. Endoscopic-assisted resection of peripheral osteoma using piezosurgery.

    PubMed

    Ochiai, Shigeki; Kuroyanagi, Norio; Sakuma, Hidenori; Sakuma, Hidenobu; Miyachi, Hitoshi; Shimozato, Kazuo

    2013-01-01

    Endoscopic-assisted surgery has gained widespread popularity as a minimally invasive procedure, particularly in the field of maxillofacial surgery. Because the surgical field around the mandibular angle is extremely narrow, the surrounding tissues may get caught in sharp rotary cutting instruments. In piezosurgery, bone tissues are selectively cut. This technique has various applications because minimal damage is caused by the rotary cutting instruments when they briefly come in contact with soft tissues. We report the case of a 33-year-old man who underwent resection of an osteoma in the region of the mandibular angle region via an intraoral approach. During surgery, the complete surgical field was within the view of the endoscope, thereby enabling the surgeon to easily resection the osteoma with the piezosurgery device. Considering that piezosurgery limits the extent of surgical invasion, this is an excellent low-risk technique that can be used in the field of maxillofacial surgery. Copyright © 2013 Elsevier Inc. All rights reserved.

  14. A CMOS One-chip Wireless Camera with Digital Image Transmission Function for Capsule Endoscopes

    NASA Astrophysics Data System (ADS)

    Itoh, Shinya; Kawahito, Shoji; Terakawa, Susumu

    This paper presents the design and implementation of a one-chip camera device for capsule endoscopes. This experimental chip integrates functional circuits required for capsule endoscopes and digital image transmission function. The integrated functional blocks include an image array, a timing generator, a clock generator, a voltage regulator, a 10b cyclic A/D converter, and a BPSK modulator. It can be operated autonomously with 3 pins (VDD, GND, and DATAOUT). A prototype image sensor chip which has 320x240 effective pixels was fabricated using 0.25μm CMOS image sensor process and the autonomous imaging was demonstrated. The chip size is 4.84mmx4.34mm. With a 2.0 V power supply, the analog part consumes 950μW and the total power consumption at 2 frames per second (fps) is 2.6mW. Error-free image transmission over a distance of 48cm at 2.5Mbps corresponding to 2fps has been succeeded with inductive coupling.

  15. Effectiveness of Intraventricular Endoscopic Lamina Terminalis Fenestration in Comparison with Standard ETV: Systematic Review of Literature.

    PubMed

    Giussani, Carlo; Guida, Lelio; Trezza, Andrea; Sganzerla, Erik Pietro

    2017-07-01

    Endoscopic third ventriculostomy is a consolidated technique for the treatment of hydrocephalus. Despite its effectiveness and feasibility, several technical limitations about its use in certain situations have been described. Lamina terminalis-endoscopic third ventriculostomy (LT-ETV) has been proposed as an alternative technique. Authors systematically reviewed the literature in order to define the effectiveness and limits in comparison with standard ETV. This systematic review followed the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) statement. It has also been registered with the PROSPERO International Prospective Register of Systematic Reviews (CRD42016041596). MEDLINE, Web of Knowledge, and EMBASE were independently searched. Seven studies were found to be eligible. A case of ours was added to the series, totaling 41 patients (mean patient age ± SD was 21.6 ± 20.7 years). Endoscopic findings leading surgeons to perform LT-ETV were abnormal ventricular anatomy (24, 57%), inadequate/insufficient interpeduncular subarachnoid space (11, 26%), a combination of both (5, 12%), and intraoperatory, unsatisfactory third ventricle floor fenestration (2, 5%). Most common pathologies were neurocysticercosis (12, 28.57%), aqueductal stenosis (8, 19%), tuberculous meningitis (4, 9.52%), and medulloblastoma (3, 7.14%). A flexible endoscope was the most used device (36 procedures, 86%), while not determining a statistical relevant diminution of complications in comparison with a rigid endoscope (P = 1.0). An overall success rate of 69% was registered, increasing to 89% if just the first year of follow-up was considered. LT-ETV can be considered a successful technical option when standard ETV cannot be performed, although more complex cerebrovascular anatomy is involved. Therefore we suggest that lateral terminalis fenestration is a valid technical option in experienced hands. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Systems workplace for endoscopic surgery.

    PubMed

    Irion, K M; Novak, P

    2000-01-01

    With the advent of minimally invasive surgery (MIS) a decade ago, the requirements for operating rooms (OR) and their equipment have been increased. Compared with conventional open surgery, the new endoscopic techniques require additional tools. Television systems, for video-assisted image acquisition and visualisation, including cameras, monitors and light systems, as well as insufflators, pumps, high-frequency units, lasers and motorised therapy units, are nowadays usually made available on carts during endoscopic surgery. In conjunction with a set of endoscopic instruments, these high-tech units allow new operating techniques to be performed. The benefit for patients has become clear in recent years; however, the technical complexity of OR has also increased considerably. To minimise this problem for the OR personnel, the MIS concept 'OR1' (Operating Room 1) was developed and implemented. OR1 is a fully functional and integrated multi-speciality surgical suite for MIS. The centrepieces of the OR1 are the Storz Communication Bus (SCB) and the advanced image and data archiving system (Aida) from Karl Storz, Tuttlingen, Germany. Both components allow monitoring, access and networking of the MIS equipment and other OR facilities, as well as the acquisition, storage and display of image, patient and equipment data during the endoscopic procedure. A central user interface allows efficient, simplified operation and online clinical images. Due to the system integration, the handling of complex equipment is considerably simplified, logistical procedures in the OR are improved, procedure times are shorter and, particularly noteworthy, operative risk can be reduced through simplified device operation.

  17. MEMS-based non-rotatory circumferential scanning optical probe for endoscopic optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Xu, Yingshun; Singh, Janak; Siang, Teo Hui; Ramakrishna, Kotlanka; Premchandran, C. S.; Sheng, Chen Wei; Kuan, Chuah Tong; Chen, Nanguang; Olivo, Malini C.; Sheppard, Colin J. R.

    2007-07-01

    In this paper, we present a non-rotatory circumferential scanning optical probe integrated with a MEMS scanner for in vivo endoscopic optical coherence tomography (OCT). OCT is an emerging optical imaging technique that allows high resolution cross-sectional imaging of tissue microstructure. To extend its usage to endoscopic applications, a miniaturized optical probe based on Microelectromechanical Systems (MEMS) fabrication techniques is currently desired. A 3D electrothermally actuated micromirror realized using micromachining single crystal silicon (SCS) process highlights its very large angular deflection, about 45 degree, with low driving voltage for safety consideration. The micromirror is integrated with a GRIN lens into a waterproof package which is compatible with requirements for minimally invasive endoscopic procedures. To implement circumferential scanning substantially for diagnosis on certain pathological conditions, such as Barret's esophagus, the micromirror is mounted on 90 degree to optical axis of GRIN lens. 4 Bimorph actuators that are connected to the mirror on one end via supporting beams and springs are selected in this micromirror design. When actuators of the micromirror are driven by 4 channels of sinusoidal waveforms with 90 degree phase differences, beam focused by a GRIN is redirected out of the endoscope by 45 degree tilting mirror plate and achieve circumferential scanning pattern. This novel driving method making full use of very large angular deflection capability of our micromirror is totally different from previously developed or developing micromotor-like rotatory MEMS device for circumferential scanning.

  18. Cecal intubation rates in different eras of endoscopic technological development.

    PubMed

    Matyja, Maciej; Pasternak, Artur; Szura, Mirosław; Pędziwiatr, Michał; Major, Piotr; Rembiasz, Kazimierz

    2018-03-01

    Colonoscopy plays a critical role in colorectal cancer (CRC) screening and has been widely regarded as the gold standard. Cecal intubation rate (CIR) is one of the well-defined quality indicators used to assess colonoscopy. To assess the impact of new technologies on the quality of colonoscopy by assessing completion rates. This was a dual-center study at the 2 nd Department of Surgery at Jagiellonian University Medical College and at the Specialist Center "Medicina" in Krakow, Poland. The CIR and cecal intubation time (CIT) in three different eras of technological advancement were determined. The study enrolled 27 463 patients who underwent colonoscopy as part of a national CRC screening program. The patients were divided into three groups: group I - 3408 patients examined between 2000 and 2003 (optical endoscopes); group II - 10 405 patients examined between 2004 and 2008 (standard electronic endoscopes); and group III - 13 650 patients examined between 2009 and 2014 (modern endoscopes). There were statistically significant differences in the CIR between successive eras. The CIR in group I (2000-2003) was 69.75%, in group II (2004-2008) was 92.32%, and in group III (2009-2014) was 95.17%. The mean CIT was significantly reduced in group III. Our study shows that the technological innovation of novel endoscopy devices has a great influence on the effectiveness of the CRC screening program. The new era of endoscopic technological development has the potential to reduce examination-related patient discomfort, obviate the need for sedation and increase diagnostic yields.

  19. Technological advances in robotic-assisted laparoscopic surgery.

    PubMed

    Tan, Gerald Y; Goel, Raj K; Kaouk, Jihad H; Tewari, Ashutosh K

    2009-05-01

    In this article, the authors describe the evolution of urologic robotic systems and the current state-of-the-art features and existing limitations of the da Vinci S HD System (Intuitive Surgical, Inc.). They then review promising innovations in scaling down the footprint of robotic platforms, the early experience with mobile miniaturized in vivo robots, advances in endoscopic navigation systems using augmented reality technologies and tracking devices, the emergence of technologies for robotic natural orifice transluminal endoscopic surgery and single-port surgery, advances in flexible robotics and haptics, the development of new virtual reality simulator training platforms compatible with the existing da Vinci system, and recent experiences with remote robotic surgery and telestration.

  20. Fluorescent Endoscopy of Tumors in Upper Part of Gastrointestinal Tract

    NASA Astrophysics Data System (ADS)

    Borisova, E.; Vladimirov, B.; Angelov, I.; Avramov, L.

    2007-04-01

    In the recent study delta-aminolevulinic acid/Protoporphyrin IX (5-ALA/PpIX) is used as fluorescent marker for dysplasia and tumor detection in esophagus and stomach. The 5-ALA is administered per os six hours before measurements at dose 20mg/kg weight. High-power light-emitting diode at 405 nm is used as an excitation source. Special opto-mechanical device is built for LED to use the light guide of standard video-endoscopic system (Olimpus Corp.). Through endoscopic instrumental channel a fiber is applied to return information about fluorescence to microspectrometer (USB4000, OceanOptics Inc.). Very good correlation between fluorescence signals and histology examination of the lesions investigated is achieved.

  1. [Laparoscopic Local Resection for a Gastric GIST with Ulcer Locating Near to the Esophagogastric Junction - A Case Report].

    PubMed

    Tanaka, Yoshihiro; Kosuga, Toshiyuki; Komatsu, Shuhei; Okamoto, Kazuma; Shoda, Katsutoshi; Arita, Tomohiro; Konishi, Hirotaka; Morimura, Ryo; Murayama, Yasutoshi; Shiozaki, Atsushi; Kuriu, Yoshiaki; Ikoma, Hisashi; Nakanishi, Masayoshi; Fujiwara, Hitoshi; Otsuji, Eigo

    2017-11-01

    A 39-year-old woman visited our hospital because of epigastric pain. Gastrointestinal endoscopy revealed a gastric submucosal tumor, 30mm in size, with ulcer locating near to the esophagogastric junction, and it was diagnosed with GIST by the endoscopic ultrasonography-guided fine needle aspiration. Then, she underwent laparoscopic surgery for the removal of gastric GIST. After peeling around the upper stomach, the local resection of the stomach was performed with linear staplers in the minor axis direction under the vision of the endoscope and laparoscope. Histopathological examinations confirmed that the tumor was GIST with an intermediate risk, and all surgical margins were free of GIST cells. Local resection with the laparoscopy endoscopy cooperative surgery(LECS)technique is a very useful way of the removal of gastric GISTs locating near to the esophagogastric junction in terms of the remnant gastric functions. Meanwhile, because the standard LECS requires the opening of the gastric lumen, there remains concerns about the intraperitoneal tumor dissemination for the gastric GIST with ulcer. We herein reported a case of laparoscopic local resection for a gastric GIST with ulcer locating near to the esophagogastric junction without gastric opening.

  2. 21 CFR 876.4890 - Urological table and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ..., stirrups, and belts used to support a patient in a suitable position for endoscopic procedures of the lower...) Class II (special controls) for the electrically powered urological table and accessories. The device is... § 876.9. (2) Class I for the manually powered table and accessories, and for stirrups for electrically...

  3. Monitoring of biofilm formation on different material surfaces of medical devices using hyperspectral imaging method

    NASA Astrophysics Data System (ADS)

    Kim, Do-Hyun; Kim, Moon S.; Hwang, Jeeseong

    2012-03-01

    Contamination of the inner surface of indwelling (implanted) medical devices by microbial biofilm is a serious problem. Some microbial bacteria such as Escherichia coli form biofilms that lead to potentially lifethreatening infections. Other types of medical devices such as bronchoscopes and duodenoscopes account for the highest number of reported endoscopic infections where microbial biofilm is one of the major causes for these infections. We applied a hyperspectral imaging method to detect biofilm contamination on the surface of several common materials used for medical devices. Such materials include stainless steel, titanium, and stainless-steeltitanium alloy. Potential uses of hyperspectral imaging technique to monitor biofilm attachment to different material surfaces are discussed.

  4. Techniques for development of safety-related software for surgical robots.

    PubMed

    Varley, P

    1999-12-01

    Regulatory bodies require evidence that software controlling potentially hazardous devices is developed to good manufacturing practices. Effective techniques used in other industries assume long timescales and high staffing levels and can be unsuitable for use without adaptation in developing electronic healthcare devices. This paper discusses a set of techniques used in practice to develop software for a particular innovative medical product, an endoscopic camera manipulator. These techniques include identification of potential hazards and tracing their mitigating factors through the project lifecycle.

  5. Endoscopic Ultrasound-guided drainage of an abdominal fluid collection following Whipple’s resection

    PubMed Central

    Jah, Asif; Jamieson, Neville; Huguet, Emmanuel; Griffiths, William; Carroll, Nicholas; Praseedom, Raaj

    2008-01-01

    Percutaneous aspiration and drainage of post-operative abdominal fluid collections is a well established standard technique. However, some fluid collections are not amenable to percutaneous drainage either due to location or the presence of surrounding visceral structures. Endoscopic Ultrasound (EUS) has been widely used for the drainage of pancreatitis-related abdominal fluid collections. However, there are no reports on the use of this technique in the post-operative setting. We report a case where the EUS-guided technique was used to drain a percutaneously inaccessible post-operative collection which had developed after Whipple’s resection. PMID:19058316

  6. Effective weight loss management with endoscopic gastric plication using StomaphyX device: is it achievable?

    PubMed

    Ong'uti, Sharon K; Ortega, Gezzer; Onwugbufor, Michael T; Ivey, Gabriel D; Fullum, Terrence M; Tran, Daniel D

    2013-01-01

    Despite the effectiveness of Roux-en-Y gastric bypass (RYGB) in promoting excess weight loss, 40% of the patients regain weight. Endoscopic gastric plication (EGP) using the StomaphyX device can serve as a less-invasive procedure for promoting the loss of regained weight. Our objective was to evaluate the effectiveness of the StomaphyX device in sustaining ongoing weight loss in patients who have regained weight after RYGB at the Division of Minimally Invasive and Bariatric Surgery, Howard University Hospital. We performed a retrospective chart review of patients undergoing EGP using the StomaphyX device from April 2008 to May 2010. The patient demographics and clinical information were assessed. Effective weight loss and the proportion of weight lost after EGP relative to the weight regained after achieving the lowest weight following RYGB was calculated. A total of 27 patients underwent EGP using the StomaphyX device; of these, most were women (n = 25, 93%) and black (n = 14, 52%), followed by white (n = 11, 42%), and Hispanic (n = 1, 4%). The median interval between RYGB and EGP was 6 years, with an interquartile range of 5-8 years. After the EGP procedure, the median effective weight loss was 37% (interquartile range 24-61%). Of the 27 patients, 18 had ≥6 months of follow-up after EGP. Eleven patients had achieved their lowest weight at 1-3 months, 7 at 6 months, and 3 at 12 months. Of the 18 patients, 13 (72%) experienced an increase in weight after achieving their lowest weight after EGP. The use of the StomaphyX device achieved the maximum effective weight loss during the 1-6-month period after EGP. Copyright © 2013 American Society for Metabolic and Bariatric Surgery. Published by Elsevier Inc. All rights reserved.

  7. Endoscopic optical coherence tomography for imaging the tympanic membrane

    NASA Astrophysics Data System (ADS)

    Burkhardt, Anke; Walther, Julia; Cimalla, Peter; Bornitz, Matthias; Koch, Edmund

    2011-06-01

    Optical coherence tomography (OCT) is an imaging modality that enables micrometer-scale contactless subsurface imaging of biological tissue. Endoscopy, as another imaging method, has the potential of imaging tubular organs and cavities and therefore has opened up several application areas not accessible before. The combination of OCT and endoscopy uses the advantages of both methods and consequently allows additional imaging of structures beneath surfaces inside cavities. Currently, visual investigations on the surface of the human tympanic membrane are possible but only with expert eyes. up to now, visual imaging of the outer ear up to the tympanic membrane can be carried out by an otoscope, an operating microscope or an endoscope. In contrast to these devices, endoscopy has the advantage of imaging the whole tympanic membrane with one view. The intention of this research is the development of an endoscopic optical coherence tomography (EOCT) device for imaging the tympanic membrane depth-resolved and structures behind it. Detection of fluids in the middle ear, which function as an indicator for otitis media, could help to avoid the application of antibiotics. It is possible to detect a congeries of fluids with the otoscope but the ambition is to the early detection by OCT. The developed scanner head allows imaging in working distances in the range from zero up to 5 mm with a field of view of 2 mm. In the next step, the scanner head should be improved to increase the working distance and the field of view.

  8. A 3D scanning laser endoscope architecture utilizing a circular piezoelectric membrane

    NASA Astrophysics Data System (ADS)

    Khayatzadeh, Ramin; Çivitci, Fehmi; Ferhanoğlu, Onur

    2017-12-01

    A piezo-scanning fiber endoscopic device architecture is proposed for 3D imaging or ablation. The endoscopic device consists of a piezoelectric membrane that is placed perpendicular to the optical axis, a fiber optic cable that extends out from and actuated by the piezoelectric membrane, and one or multiple lenses for beam delivery and collection. Unlike its counterparts that utilize piezoelectric cylinders for fiber actuation, the proposed architecture offers quasi-static actuation in the axial direction along with resonant actuation in the lateral directions forming a 3D scanning pattern, allowing adjustment of the focus plane. The actuation of the four-quadrant piezoelectric membrane involves driving of two orthogonal electrodes with AC signals for lateral scanning, while simultaneously driving all electrodes for axial scanning and focus adjustment. We have characterized piezoelectric membranes (5 -15mm diameter) with varying sizes to monitor axial displacement behavior with respect to applied DC voltage. We also demonstrate simultaneous lateral and axial actuation on a resolution target, and observe the change of lateral resolution on a selected plane through performing 1D cross-sectional images, as an indicator of focal shift through axial actuation. Based on experimental results, we identify the optical and geometrical parameters for optimal 3D imaging of tissue samples. Our findings reveal that a simple piezoelectric membrane, having comparable dimensions and drive voltage requirement with off-the-shelf MEMS scanner chips, offers tissue epithelial imaging with sub-cellular resolution.

  9. A novel device for endoscopic submucosal dissection, the Fork knife

    PubMed Central

    Kim, Hyun Gun; Cho, Joo Young; Bok, Gene Hyun; Cho, Won Young; Kim, Wan Jung; Hong, Su Jin; Ko, Bong Min; Kim, Jin Oh; Lee, Joon Seong; Lee, Moon Sung; Shim, Chan Sup

    2008-01-01

    AIM: To introduce and evaluate the efficacy and technical aspects of endoscopic submucosal dissection (ESD) using a novel device, the Fork knife. METHODS: From March 2004 to April 2008, ESD was performed on 265 gastric lesions using a Fork knife (Endo FS®) (group A) and on 72 gastric lesions using a Flexknife (group B) at a single tertiary referral center. We retrospectively compared the endoscopic characteristics of the tumors, pathological findings, and sizes of the resected specimens. We also compared the en bloc resection rate, complete resection rate, complications, and procedure time between the two groups. RESULTS: The mean size of the resected specimens was 4.27 ± 1.26 cm in group A and 4.29 ± 1.48 cm in group B. The en bloc resection rate was 95.8% (254/265 lesions) in group A and 93.1% (67/72) in group B. Complete ESD without tumor cell invasion of the resected margin was obtained in 81.1% (215/265) of group A and in 73.6% (53/72) of group B. The perforation rate was 0.8% (2/265) in group A and 1.4% (1/72) in group B. The mean procedure time was 59.63 ± 56.12 min in group A and 76.65 ± 70.75 min in group B (P < 0.05). CONCLUSION: The Fork knife (Endo FS®) is useful for clinical practice and has the advantage of reducing the procedure time. PMID:19034979

  10. Prevention of multidrug-resistant infections from contaminated duodenoscopes: Position Statement of the European Society of Gastrointestinal Endoscopy (ESGE) and European Society of Gastroenterology Nurses and Associates (ESGENA).

    PubMed

    Beilenhoff, Ulrike; Biering, Holger; Blum, Reinhard; Brljak, Jadranka; Cimbro, Monica; Dumonceau, Jean-Marc; Hassan, Cesare; Jung, Michael; Neumann, Christiane; Pietsch, Michael; Pineau, Lionel; Ponchon, Thierry; Rejchrt, Stanislav; Rey, Jean-François; Schmidt, Verona; Tillett, Jayne; van Hooft, Jeanin

    2017-11-01

    Patients should be informed about the benefits and risks of endoscopic retrograde cholangiopancreatography (ERCP)Only specially trained and competent personnel should carry out endoscope reprocessing.Manufacturers of duodenoscopes should provide detailed instructions on how to use and reprocess their equipment.In the case of modifications to their equipment, manufacturers should provide updated instructions for use.Detailed reprocessing protocols based on the manufacturer's instructions for use should clearly lay out the different reprocessing steps necessary for each endoscope model.Appropriate cleaning equipment should be used for duodenoscopes in compliance with the manufacturer's instructions for use. Only purpose-designed, endoscope type-specific, single-use cleaning brushes should be used, to ensure optimal cleaning. As soon as the endoscope is withdrawn from the patient, bedside cleaning should be performed, followed by leak testing, thorough manual cleaning steps, and automated reprocessing, in order to: · Remove debris from external and internal surfaces;. · Prevent any drying of body fluids, blood, or debris;. · Prevent any formation of biofilms.. In addition to the leak test, visual inspection of the distal end as well as regular maintenance of duodenoscopes should be performed according to the manufacturer's instructions for use, in order to detect any damage at an early stage.The entire reprocessing procedure in endoscope washer-disinfectors (EWDs) should be validated according to the European and International Standard, EN ISO 15883. Routine technical tests of EWDs should be performed according to the validation reports.Microbiological surveillance of a proportion of the department's endoscopes should be performed every 3 months, with the requirement that all endoscopes used in the unit are tested at least once a year.In the case of suspected endoscopy-related infection, the relevant device (e. g., endoscope, EWD) should be taken out of service until adequate corrective actions have been taken. Outbreaks should be managed by a multidisciplinary team, including endoscopy, hygiene, and microbiology experts, manufacturers, and regulatory bodies, according to national standards and/or laws. In the case of suspected multidrug-resistant organism (MDRO) outbreaks, close cooperation between the endoscopy unit and the clinical health provider is essential (including infection control departments and hospital hygienists). © Georg Thieme Verlag KG Stuttgart · New York.

  11. Primary tracheobronchial tumors in children.

    PubMed

    Varela, Patricio; Pio, Luca; Torre, Michele

    2016-06-01

    Primary tracheobronchial tumors are rare lesions that can be benign or malignant, with different location along the airway tree. Symptoms may include wheezing, chronic pneumonia, asthma, chest pain, recurrent cough, atelectasis, haemoptysis, and weight loss. Due to the heterogeneity of symptoms, diagnosis can be difficult and the airway involvement can lead progressively to a bronchial or tracheal obstruction. Due to the rarity of primary tracheobronchial tumors in children, there are not any oncological guidelines on pre-operative work-up, treatment, and follow-up. Only few reports and multicentric studies are reported. In most cases, surgical resection seems to be the treatment of choice. Brachytherapy, endoscopic treatment, and chemotherapy are rarely described. In this article we present an overview on these rare tumors, including pathological aspects, clinical presentation, imaging assessment, and endoscopic or open surgical treatments. We discuss different surgical approaches, according with tumor location. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Ingestible wireless capsules for enhanced diagnostic inspection of gastrointestinal tract

    NASA Astrophysics Data System (ADS)

    Rasouli, Mahdi; Kencana, Andy Prima; Huynh, Van An; Ting, Eng Kiat; Lai, Joshua Chong Yue; Wong, Kai Juan; Tan, Su Lim; Phee, Soo Jay

    2011-03-01

    Wireless capsule endoscopy has become a common procedure for diagnostic inspection of gastrointestinal tract. This method offers a less-invasive alternative to traditional endoscopy by eliminating uncomfortable procedures of the traditional endoscopy. Moreover, it provides the opportunity for exploring inaccessible areas of the small intestine. Current capsule endoscopes, however, move by peristalsis and are not capable of detailed and on-demand inspection of desired locations. Here, we propose and develop two wireless endoscopes with maneuverable vision systems to enhance diagnosis of gastrointestinal disorders. The vision systems in these capsules are equipped with mechanical actuators to adjust the position of the camera. This may help to cover larger areas of the digestive tract and investigate desired locations. The preliminary experimental results showed that the developed platform could successfully communicate with the external control unit via human body and adjust the position of camera to limited degrees.

  13. Endoscopic Endonasal Approach in Skull Base Chondrosarcoma Associated with Maffucci Syndrome: Case Series and Literature Review.

    PubMed

    Beer-Furlan, André; Balsalobre, Leonardo; Vellutini, Eduardo A S; Stamm, Aldo C

    2016-01-01

    Maffucci syndrome is a nonhereditary disorder in which patients develop multiple enchondromas and cutaneous, visceral, or soft tissue hemangiomas. The potential malignant progression of enchondroma into a secondary chondrosarcoma is a well-known fact. Nevertheless, chondrosarcoma located at the skull base in patients with Maffuci syndrome is a very rare condition, with only 18 cases reported in the literature. We report 2 other cases successfully treated through an expanded endoscopic endonasal approach and discuss the condition based on the literature review. Skull base chondrosarcoma associated with Maffucci syndrome is a rare condition. The disease cannot be cured, therefore surgical treatment should be performed in symptomatic patients aiming for maximal tumor resection with function preservation. The endoscopic endonasal approach is a safe and reliable alternative for the management of these tumors. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Expanded Endoscopic Transnasal Approach to the Chordoid Glioma of the Third Ventricle : The First Case Ever Reported.

    PubMed

    Zeinalizadeh, Mehdi; Sadrehosseini, Seyed Mousa; Tayebi Meybodi, Keyvan; Sharifabadi, Ali Heidari

    2016-11-01

    Chordoid glioma of the third ventricle is a rare and challenging tumor to surgery because of its unique anatomical location and its close juxtaposition to the neurovascular structures and hypothalamus. The authors report a case of chordoid glioma of the third ventricle in a 43-year-old woman, who presented with headache and somnolence. The tumor was approached by endoscopic transnasal technique with a favorable result. Histopathologic examination disclosed a neoplastic tissue composed of eosinophilic epithelioid cells, mucinous, periodic acid Schiff-diastase positive, extracellular matrix, and scattered lymphoplasmacytic infiltrates. The best treatment option remains controversial. Customarily, the surgical route to remove chordoid glioma is transcranial; however, the undersurface of the optic chiasm and optic nerves preclude an adequate surgical visualization. In contrast, an expanded endoscopic transnasal approach provides a direct midline corridor to this region without any brain retraction.

  15. Medical and Endoscopic Management of Gastric Varices

    PubMed Central

    Al-Osaimi, Abdullah M. S.; Caldwell, Stephen H.

    2011-01-01

    In the past 20 years, our understanding of the pathophysiology and management options among patients with gastric varices (GV) has changed significantly. GV are the most common cause of upper gastrointestinal bleeding in patients with portal hypertension after esophageal varices (EV) and generally have more severe bleeding than EV. In the United States, the majority of GV patients have underlying portal hypertension rather than splenic vein thrombosis. The widely used classifications are the Sarin Endoscopic Classification and the Japanese Vascular Classifications. The former is based on the endoscopic appearance and location of the varices, while the Japanese classification is based on the underlying vascular anatomy. In this article, the authors address the current concepts of classification, epidemiology, pathophysiology, and emerging management options of gastric varices. They describe the stepwise approach to patients with gastric varices, including the different available modalities, and the pearls, pitfalls, and stop-gap measures useful in managing patients with gastric variceal bleed. PMID:22942544

  16. The Role of Therapeutic Endoscopy in Patients With Cirrhosis-Related Causes of Gastrointestinal Bleeding.

    PubMed

    Kezer, Camille A; Gupta, Neil

    2018-06-09

    This article aims to review current therapeutic endoscopic treatments available for the management of gastrointestinal bleeding related to cirrhosis. Endoscopic band ligation is an effective treatment for primary prophylaxis, acute bleeding, and secondary prophylaxis of esophageal varices as well as for acute bleeding and secondary prophylaxis of select gastric varices. Sclerotherapy is a treatment option for acute bleeding and secondary prophylaxis of esophageal varices when band ligation is technically difficult. Cyanoacrylate glue injection is an effective treatment for acute bleeding of gastric and ectopic varices. Argon plasma coagulation is first-line and radiofrequency ablation is second-line treatment for chronic bleeding secondary to gastric antral vascular ectasia. There are a variety of endoscopic treatment modalities for cirrhosis-related gastrointestinal bleeding, and the appropriate therapy depends on the location of the bleed, history or presence of acute bleeding, and risk factors for intervention-related adverse events.

  17. Endoscopic removal of a tablespoon lodged within the duodenum

    PubMed Central

    Watanabe, Takashi; Aoyagi, Kunihiko; Tomioka, Yoshitaka; Ishibashi, Hideki; Sakisaka, Shotaro

    2015-01-01

    Here we report the case of a 34-year-old man who underwent endoscopic removal of a tablespoon from the stomach that was lodged within the duodenum. Removal required the use of a two-channel upper endoscope and polypectomy snares. Using the double-snare technique, the spoon was grasped at the proximal and distal parts of the handle. The double-snare was first pulled unsuccessfully and then pulled with simultaneous manual abdominal compression of the bulbus from the body surface. Compression was gently applied towards the stomach. As a result, the head of the spoon prolapsed from the bulbus, and was easily retracted from the stomach without any complications. In cases of foreign body lodging within the duodenum, the manual abdominal compression technique may help clinicians pull out the object and avoid surgery. The usefulness of manual compression is dependent on the foreign body’s sharpness and the location. PMID:25945026

  18. Correlation Between Findings of Multislice Helical Computed Tomography (CT), Endoscopic Examinations, Endovascular Procedures, and Surgery in Patients with Symptoms of Acute Gastrointestinal Bleeding.

    PubMed

    Konecki, Dariusz; Grabowska-Derlatka, Laretta; Pacho, Ryszard; Rowiński, Olgierd

    2017-01-01

    Endoscopic methods (gastroscopy and colonoscopy) are considered fundamental for the diagnosis of gastrointestinal bleeding. In recent years, multidetector computed tomography (MDCT) has also gained importance in diagnosing gastrointestinal bleeding, particularly in hemodynamically unstable patients and in cases with suspected lower gastrointestinal tract bleeding. CT can detect both the source and the cause of active gastrointestinal bleeding, thereby expediting treatment initiation. The study group consisted of 16 patients with clinical symptoms of gastrointestinal bleeding in whom features of active bleeding were observed on CT. In all patients, bleeding was verified by means of other methods such as endoscopic examinations, endovascular procedures, or surgery. The bleeding source was identified on CT in all 16 patients. In 14 cases (87.5%), bleeding was confirmed by other methods. CT is an efficient, fast, and readily available tool for detecting the location of acute gastrointestinal bleeding.

  19. Variable-focus side-firing endoscopic device

    NASA Astrophysics Data System (ADS)

    Lemberg, Vladimir G.; Black, Michael

    1996-05-01

    Conventional side-firing fiber technology exhibits performance limitations and utilizes expensive single-use only devices which often require multiple fibers for laser prostatectomy. Another limitation of existing side-firing fiber technology is its inability to focus the beam to create incisions for urologic applications such as laser TURP (transurethral resectional prostatectomy), tumor necrosis, lithotripsy, genital warts, and photodynamic therapy. Newly introduced variable-focus side-firing endoscopic device utilizes either one or two lenses and a mirror, onto a single cylinder of molded glass. The laser beam exits the optical fiber, passes through the lens, strikes the cylindrical mirror, and traverses the cylindrical surface. Depending on the design, the laser beam is reflected at the angles ranging from 30 degrees to 120 degrees out of the cylindrical lens. A second lens can be formed onto the side of the cylindrical surface at the beam's exit point. Another advantage of the innovative side-firing device is its capability to provide versatile matching to multiple laser wavelengths from 360 nm to 2.5 microns, and achieve power densities great enough to perform vaporization, incision and coagulation of tissue. Precise focusing of the laser beam results in reduced tissue necrosis of surrounding the treatment area as well as in decreased laser radiation back-scattering. Surgeons can very the focus by adjusting the distance from the tip to the target area. The variable focus side-firing device provides a focused beam at the range of 1.0 to 1.5 mm, for incision. Outside this range, it produces a defocused beam for coagulation.

  20. Methodological proposal for validation of the disinfecting efficacy of an automated flexible endoscope reprocessor

    PubMed Central

    Graziano, Kazuko Uchikawa; Pereira, Marta Elisa Auler; Koda, Elaine

    2016-01-01

    ABSTRACT Objective: to elaborate and apply a method to assess the efficacy of automated flexible endoscope reprocessors at a time when there is not an official method or trained laboratories to comply with the requirements described in specific standards for this type of health product in Brazil. Method: the present methodological study was developed based on the following theoretical references: International Organization for Standardization (ISO) standard ISO 15883-4/2008 and Brazilian Health Surveillance Agency (Agência Nacional de Vigilância Sanitária - ANVISA) Collegiate Board Resolution (Resolução de Diretoria Colegiada - RDC) no. 35/2010 and 15/2012. The proposed method was applied to a commercially available device using a high-level 0.2% peracetic acid-based disinfectant. Results: the proposed method of assessment was found to be robust when the recommendations made in the relevant legislation were incorporated with some adjustments to ensure their feasibility. Application of the proposed method provided evidence of the efficacy of the tested equipment for the high-level disinfection of endoscopes. Conclusion: the proposed method may serve as a reference for the assessment of flexible endoscope reprocessors, thereby providing solid ground for the purchase of this category of health products. PMID:27508915

  1. Local resection of the stomach for gastric cancer.

    PubMed

    Kinami, Shinichi; Funaki, Hiroshi; Fujita, Hideto; Nakano, Yasuharu; Ueda, Nobuhiko; Kosaka, Takeo

    2017-06-01

    The local resection of the stomach is an ideal method for preventing postoperative symptoms. There are various procedures for performing local resection, such as the laparoscopic lesion lifting method, non-touch lesion lifting method, endoscopic full-thickness resection, and laparoscopic endoscopic cooperative surgery. After the invention and widespread use of endoscopic submucosal dissection, local resection has become outdated as a curative surgical technique for gastric cancer. Nevertheless, local resection of the stomach in the treatment of gastric cancer in now expected to make a comeback with the clinical use of sentinel node navigation surgery. However, there are many issues associated with local resection for gastric cancer, other than the normal indications. These include gastric deformation, functional impairment, ensuring a safe surgical margin, the possibility of inducing peritoneal dissemination, and the associated increase in the risk of metachronous gastric cancer. In view of these issues, there is a tendency to regard local resection as an investigative treatment, to be applied only in carefully selected cases. The ideal model for local resection of the stomach for gastric cancer would be a combination of endoscopic full-thickness resection of the stomach using an ESD device and hand sutured closure using a laparoscope or a surgical robot, for achieving both oncological safety and preserved functions.

  2. Value of focal applied energy quotient in treatment of ureteral lithiasis with shock waves.

    PubMed

    Arrabal-Polo, Miguel Angel; Arrabal-Martin, Miguel; Palao-Yago, Francisco; Mijan-Ortiz, Jose Luis; Zuluaga-Gomez, Armando

    2012-08-01

    The treatment of ureteral lithiasis by extracorporeal shock wave lithotripsy (ESWL) is progressively being abandoned owing to advances in endoscopic lithotripsy. The purpose of this paper is to analyze the causes as to why ESWL is less effective-with a measurable parameter: focal applied energy quotient (FAEQ) that allows us to apply an improvement project in ESWL results for ureteral lithiasis. A prospective observational cohort study with 3-year follow-up and enrollment period was done with three groups of cases. In Group A, 83 cases of ureteral lithiasis were treated by endoscopic lithotripsy using Holmiun:YAG laser. In Group B, 81 cases of ureteral lithiasis were treated by ESWL using Doli-S device (EMSE 220F-XXP). In Group C, 65 cases of ureteral lithiasis were treated by ESWL using Doli-S device (EMSE 220F-XXP) (FAEQ >10). Statistical study and calculation of RR, NNT, Chi-square test, Fisher's exact test, and Student's t test were done. Efficiency quotient (EQ) and focal applied energy quotient [FAEQ = (radioscopy seconds/number of shock waves) × ESWL session J] were analyzed. From the results, the success rate of the treatment using Holmium:YAG laser lithotripsy and ESWL is found to be 94 and 48%, respectively, with a statistically significant difference (p < 0.001). Success rate of endoscopic laser lithotripsy for lumbar ureteral stones was 82% versus 57% of ESWL (p = 0.611). In Group B, FAEQ was 8.12. In Group C, success rate was 93.84% with FAEQ of 10.64%. When we compare results from endoscopic lithotripsy with Holmium:YAG laser in Group B with results from ESWL with FAEQ >10, we do not observe absolute benefit choosing one or the other. In conclusion, the application of ESWL with FAEQ >10, that is, improving radiologic focalization of the calculus and increasing the number of Joules/SW, makes possible a treatment as safe and equally efficient as Holmium:YAG laser lithotripsy in ureteral lithiasis less than 13 mm.

  3. Hybrid Microscopic-Endoscopic Surgery for Craniopharyngioma in Neurosurgical Suite: Technical Notes.

    PubMed

    Ichikawa, Tomotsugu; Otani, Yoshihiro; Ishida, Joji; Fujii, Kentaro; Kurozumi, Kazuhiko; Ono, Shigeki; Date, Isao

    2016-01-01

    The best chance of curing craniopharyngioma is achieved by microsurgical total resection; however, its location adjacent to critical structures hinders complete resection without neurologic deterioration. Unrecognized residual tumor within microscopic blind spots might result in tumor recurrences. To improve outcomes, new techniques are necessary to visualize tissue within these blind spots. We examined the success of hybrid microscopic-endoscopic neurosurgery for craniopharyngioma in a neurosurgical suite. Four children with craniopharyngiomas underwent microscopic resection. When the neurosurgeon was confident that most of the visible tumor was removed but was suspicious of residual tumor within the blind spot, he or she used an integrated endoscope-holder system to inspect and remove any residual tumor. Two ceiling monitors were mounted side by side in front of the surgeon to display both microscopic and endoscopic views and to view both monitors simultaneously. Surgery was performed in all patients via the frontobasal interhemispheric approach. Residual tumors were observed in the sella (2 patients), on the ventral surface of the chiasm and optic nerve (1 patient), and in the third ventricle (1 patient) and were resected to achieve total resection. Postoperatively, visual function was improved in 2 patients and none exhibited deterioration related to the surgery. Simultaneous microscopic and endoscopic observation with the use of dual monitors in a neurosurgical suite was ergonomically optimal for the surgeon to perform microsurgical procedures and to avoid traumatizing surrounding vessels or neural tissues. Hybrid microscopic-endoscopic neurosurgery may contribute to safe, less-invasive, and maximal resection to achieve better prognosis in children with craniopharyngioma. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. Risk factors for under-diagnosis of gastric intraepithelial neoplasia and early gastric carcinoma in endoscopic forceps biopsy in comparison with endoscopic submucosal dissection in Chinese patients.

    PubMed

    Xu, Guifang; Zhang, Weijie; Lv, Ying; Zhang, Bin; Sun, Qi; Ling, Tingsheng; Zhang, Xiaoqi; Zhou, Zhihua; Wang, Lei; Huang, Qin; Zou, Xiaoping

    2016-07-01

    Differences in pathologic diagnosis between endoscopic forceps biopsy (EFB) and endoscopic submucosal dissection (ESD) for gastric intraepithelial neoplasia (GIN) and early gastric carcinoma (EGC) in Chinese patients remain unknown. The aim of the study was to investigate risk factors for under-diagnosed pathology in initial EFB, compared to final ESD. We reviewed endoscopic and histopathologic findings for tumor location, size, macroscopic pattern, nodularity, erythema, erosion, GIN (low and high grade), and EGC diagnosed with the WHO criteria. Differences in those features between EFB and ESD were compared and risk factors for under-diagnosis by EFB were analyzed. Although concordant in most (74.9 %) cases between EFBs and ESDs, pathological diagnoses in 57 (25.1 %) cases were upgraded in ESDs. Compared to the concordant group, the lesion size ≥2 cm, and depressed and excavated patterns were significantly more frequent in the upgraded group. Further multivariate regression analysis demonstrated the depressed pattern and lesion size ≥2 cm as independent risk factors for upgraded pathology with the odds ratio of 5.778 (95 % confidence interval 2.893-11.542) and 2.535 (95 % confidence interval 1.257-5.111), respectively. Lesion size ≥2.0 cm and the depressed pattern at initial EFB were independent risk factors for pathologic upgrade to advanced diseases in ESD. Therefore, these endoscopic characteristics should be considered together with the initial EFB diagnosis to guide the optimal clinical management of patients with GIN and EGC.

  5. Use of adenosine triphosphate to audit reprocessing of flexible endoscopes with an elevator mechanism.

    PubMed

    Quan, Erik; Mahmood, Rizwan; Naik, Amar; Sargon, Peter; Shastri, Nikhil; Venu, Mukund; Parada, Jorge P; Gupta, Neil

    2018-05-21

    There have been reported outbreaks of carbapenem-resistant Enterobacteriaceae infections linked to endoscopes with elevator mechanisms. Adenosine triphosphate (ATP) testing has been used as a marker for bioburden and monitoring manual cleaning for flexible endoscopes with and without an elevator mechanism. The objective of this study was to determine whether routine ATP testing could identify areas of improvement in cleaning of endoscopes with an elevator mechanism. ATP testing after manual cleaning of TJF-Q180V duodenoscopes and GF-UCT180 linear echoendoscopes (Olympus America Inc, Center Valley, PA) was implemented. Samples were tested from the distal end, the elevator mechanism, and water flushed through the lumen of the biopsy channel. Data were recorded and compared by time point, test point, and reprocessing technician. Overall failure rate was 6.99% (295 out of 4,219). The highest percentage of failed ATP tests (17.05%) was reported in the first quarter of routine testing, with an overall decrease in rates over time. The elevator mechanism and working channel lumen had higher failure rates than the distal end. Quality of manual cleaning between reprocessing technicians showed variation. ATP testing is effective in identifying residual organic material and improving quality of manual cleaning of endoscopes with an elevator mechanism. Cleaning efficacy is influenced by reprocessing technicians and location tested on the endoscope. Close attention to the working channel and elevator mechanism during manual cleaning is warranted. Copyright © 2018 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  6. Safe and successful endoscopic initial treatment and long-term eradication of gastric varices by endoscopic ultrasound-guided Histoacryl (N-butyl-2-cyanoacrylate) injection.

    PubMed

    Gubler, Christoph; Bauerfeind, Peter

    2014-09-01

    Optimal endoscopic treatment of gastric varices is still not standardized nowadays. Actively bleeding varices may prohibit a successful endoscopic injection therapy of Histoacryl® (N-butyl-2-cyanoacrylate). Since 2006, we have treated gastric varices by standardized endoscopic ultrasound (EUS) guided Histoacryl injection therapy without severe adverse events. We present a large single-center cohort over 7 years with a standardized EUS-guided sclerotherapy of all patients with gastric varices. Application was controlled by fluoroscopy to immediately detect any glue embolization. Only perforating veins located within the gastric wall were treated. In the follow up, we repeated this treatment until varices were eradicated. Utmost patients (36 of 40) were treated during or within 24 h of active bleeding. About 32.5% of patients were treated while visible bleeding. Histoacryl injection was always technically successful and only two patients suffered a minor complication. Acute bleeding was stopped in all patients. About 15% (6 of 40) of patients needed an alternative rescue treatment in the longer course. Three patients got a transjugular portosystemic shunt and another three underwent an orthotopic liver transplantation. Mean long-term survival of 60 months was excellent. Active bleeding of gastric varices can be treated successfully without the necessity of gastric rinsing with EUS-guided injection of Histoacryl.

  7. Splash M-knife versus Flush Knife BT in the technical outcomes of endoscopic submucosal dissection for early gastric cancer: a propensity score matching analysis.

    PubMed

    Esaki, Mitsuru; Suzuki, Sho; Hayashi, Yasuyo; Yokoyama, Azusa; Abe, Shuichi; Hosokawa, Taizo; Ogino, Haruei; Akiho, Hirotada; Ihara, Eikichi; Ogawa, Yoshihiro

    2018-02-27

    Endoscopic submucosal dissection (ESD) is a standard treatment for early gastric cancer. A new multi-functional ESD device was developed to achieve complete ESD with a single device. A metal plate attached to its distal sheath achieves better hemostasis during the procedure than the other needle-knife device, Flush Knife BT®, that has been conventionally used. The aim of this study was to compare the technical outcomes of ESD for early gastric cancer using the Splash M-Knife® with those using the Flush Knife BT. We conducted a retrospective review of the case records of 149 patients with early gastric cancer treated with ESD using the needle-type ESD knives between January 2012 and August 2016 at Kitakyushu Municipal Medical Center. Lesions treated with ESD using the Splash M-knife (ESD-M) and the Flush Knife BT (ESD-F) were compared. Multivariate analyses and propensity score matching were used to compensate for the differences in age, gender, underlying disease, antithrombotic drug use, lesion location, lesion position, macroscopic type, tumor size, presence of ulceration, operator level and types of electrosurgical unit used. The primary endpoint was the requirement to use hemostatic forceps in the two groups. The secondary endpoints of procedure time, en bloc and complete resection rates, and adverse events rates were evaluated for the two groups. There were 73 patients in the ESD-M group, and 76 patients in the ESD-F group. Propensity score matching analysis created 45 matched pairs. Adjusted comparisons between the two groups showed a significantly lower usage rate of hemostatic forceps in the ESD-M group than in the ESD-F group (6.7% vs 84.4%, p < 0.001). Treatment outcomes showed an en bloc resection rate of 100% in both groups; complete resection rate of 95.6% vs 100%, p = 0.49; median procedure time of 74.0 min vs 71.0 min, p = 0.90; post-procedure bleeding of 2.2% vs 2.2%, p = 1, in the ESD-M and ESD-F groups, respectively. There were no perforations in either group. ESD-M appeared to reduce the usage of hemostatic forceps during ESD for early gastric cancer without increasing the adverse effects. Thus, it may contribute to a reduction in the total ESD cost.

  8. Control devices and steering strategies in pathway surgery.

    PubMed

    Fan, Chunman; Jelínek, Filip; Dodou, Dimitra; Breedveld, Paul

    2015-02-01

    For pathway surgery, that is, minimally invasive procedures carried out transluminally or through instrument-created pathways, handheld maneuverable instruments are being developed. As the accompanying control interfaces of such instruments have not been optimized for intuitive manipulation, we investigated the effect of control mode (1DoF or 2DoF), and control device (joystick or handgrip) on human performance in a navigation task. The experiments were conducted using the Endo-PaC (Endoscopic-Path Controller), a simulator that emulates the shaft and handle of a maneuverable instrument, combined with custom-developed software animating pathway surgical scenarios. Participants were asked to guide a virtual instrument without collisions toward a target located at the end of a virtual curved tunnel. The performance was assessed in terms of task completion time, path length traveled by the virtual instrument, motion smoothness, collision metrics, subjective workload, and personal preference. The results indicate that 2DoF control leads to faster task completion and fewer collisions with the tunnel wall combined with a strong subjective preference compared with 1DoF control. Handgrip control appeared to be more intuitive to master than joystick control. However, the participants experienced greater physical demand and had longer path lengths with handgrip than joystick control. Copyright © 2015 Elsevier Inc. All rights reserved.

  9. 21 CFR 884.1560 - Fetal blood sampler.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Fetal blood sampler. 884.1560 Section 884.1560... § 884.1560 Fetal blood sampler. (a) Identification. A fetal blood sampler is a device used to obtain fetal blood transcervically through an endoscope by puncturing the fetal skin with a short blade and...

  10. 21 CFR 884.1560 - Fetal blood sampler.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Fetal blood sampler. 884.1560 Section 884.1560... § 884.1560 Fetal blood sampler. (a) Identification. A fetal blood sampler is a device used to obtain fetal blood transcervically through an endoscope by puncturing the fetal skin with a short blade and...

  11. 21 CFR 884.1560 - Fetal blood sampler.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Fetal blood sampler. 884.1560 Section 884.1560... § 884.1560 Fetal blood sampler. (a) Identification. A fetal blood sampler is a device used to obtain fetal blood transcervically through an endoscope by puncturing the fetal skin with a short blade and...

  12. 21 CFR 884.1560 - Fetal blood sampler.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Fetal blood sampler. 884.1560 Section 884.1560... § 884.1560 Fetal blood sampler. (a) Identification. A fetal blood sampler is a device used to obtain fetal blood transcervically through an endoscope by puncturing the fetal skin with a short blade and...

  13. 21 CFR 884.1560 - Fetal blood sampler.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Fetal blood sampler. 884.1560 Section 884.1560... § 884.1560 Fetal blood sampler. (a) Identification. A fetal blood sampler is a device used to obtain fetal blood transcervically through an endoscope by puncturing the fetal skin with a short blade and...

  14. Application of radiofrequency energy in surgical and interventional procedures: are there interactions with ICDs?

    PubMed

    Fiek, Michael; Dorwarth, Uwe; Durchlaub, Ilka; Janko, Sabine; Von Bary, Christian; Steinbeck, Gerhard; Hoffmann, Ellen

    2004-03-01

    During surgical and interventional procedures, interference may occur between ICDs and electrical cautery or with the application of RF energy. This may lead to the false induction of ICD therapies or could even result in device malfunction, which represents a potential perioperative hazard for the patient. This study analyzed the intraoperative interactions in 45 consecutive ICD patients in reference to different surgical and interventional procedures. A total of 33 surgical operations (general surgery [n = 14], urologic [n = 5], abdominal [n = 10], gynecological [n = 2], thoracic [n = 1], neurosurgical [n = 1]) and 12 interventional therapies (RF catheter ablation [n = 10], endoscopic papillotomy [n = 2]) were performed. The ICD devices were all located in left pectoral position and consisted of 25 single and 20 dual chamber defibrillators. During the procedure, tachyarrhythmia detection (VF 296 +/- 20 ms, VT 376 +/- 49 ms) of the devices was maintained active (monitoring mode), only ICD therapies were inactivated. The indifferent electrode of the electrical cauter/RF generator was placed in standard positions (right/left mid-femoral position [n = 27/8], thoracic spine area [n = 10]). After the procedure, the ICD memory was checked for detections and for changes in the programming. There was no oversensing, reprogramming, or damage of any defibrillator caused by RF energy. Despite the lack of undesired interactions, ICDs should be inactivated preoperatively to assure maximum patient safety. However, should inactivation not be possible, or the achievement uncertain, electromagnetic interference is highly unlikely.

  15. Towards real time 2D to 3D registration for ultrasound-guided endoscopic and laparoscopic procedures.

    PubMed

    San José Estépar, Raúl; Westin, Carl-Fredrik; Vosburgh, Kirby G

    2009-11-01

    A method to register endoscopic and laparoscopic ultrasound (US) images in real time with pre-operative computed tomography (CT) data sets has been developed with the goal of improving diagnosis, biopsy guidance, and surgical interventions in the abdomen. The technique, which has the potential to operate in real time, is based on a new phase correlation technique: LEPART, which specifies the location of a plane in the CT data which best corresponds to the US image. Validation of the method was carried out using an US phantom with cyst regions and with retrospective analysis of data sets from animal model experiments. The phantom validation study shows that local translation displacements can be recovered for each US frame with a root mean squared error of 1.56 +/- 0.78 mm in less than 5 sec, using non-optimized algorithm implementations. A new method for multimodality (preoperative CT and intraoperative US endoscopic images) registration to guide endoscopic interventions was developed and found to be efficient using clinically realistic datasets. The algorithm is inherently capable of being implemented in a parallel computing system so that full real time operation appears likely.

  16. A novel endoscopic fluorescent band ligation method for tumor localization.

    PubMed

    Hyun, Jong Hee; Kim, Seok-Ki; Kim, Kwang Gi; Kim, Hong Rae; Lee, Hyun Min; Park, Sunup; Kim, Sung Chun; Choi, Yongdoo; Sohn, Dae Kyung

    2016-10-01

    Accurate tumor localization is essential for minimally invasive surgery. This study describes the development of a novel endoscopic fluorescent band ligation method for the rapid and accurate identification of tumor sites during surgery. The method utilized a fluorescent rubber band, made of indocyanine green (ICG) and a liquid rubber solution mixture, as well as a near-infrared fluorescence laparoscopic system with a dual light source using a high-powered light-emitting diode (LED) and a 785-nm laser diode. The fluorescent rubber bands were endoscopically placed on the mucosae of porcine stomachs and colons. During subsequent conventional laparoscopic stomach and colon surgery, the fluorescent bands were assayed using the near-infrared fluorescence laparoscopy system. The locations of the fluorescent clips were clearly identified on the fluorescence images in real time. The system was able to distinguish the two or three bands marked on the mucosal surfaces of the stomach and colon. Resection margins around the fluorescent bands were sufficient in the resected specimens obtained during stomach and colon surgery. These novel endoscopic fluorescent bands could be rapidly and accurately localized during stomach and colon surgery. Use of these bands may make possible the excision of exact target sites during minimally invasive gastrointestinal surgery.

  17. Preoperative Navigated Transcranial Magnetic Stimulation and Tractography to Guide Endoscopic Cystoventriculostomy: A Technical Note and Case Report.

    PubMed

    Hendrix, Philipp; Senger, Sebastian; Griessenauer, Christoph J; Simgen, Andreas; Linsler, Stefan; Oertel, Joachim

    2018-01-01

    To report a technique for endoscopic cystoventriculostomy guided by preoperative navigated transcranial magnetic stimulation (nTMS) and tractography in a patient with a large speech eloquent arachnoid cyst. A 74-year old woman presented with a seizure and subsequent persistent anomic aphasia from a progressive left-sided parietal arachnoid cyst. An endoscopic cystoventriculostomy and endoscope-assisted ventricle catheter placement were performed. Surgery was guided by preoperative nTMS and tractography to avoid eloquent language, motor, and visual pathways. Preoperative nTMS motor and language mapping were used to guide tractography of motor and language white matter tracts. The ideal locations of entry point and cystoventriculostomy as well as trajectory for stent-placement were determined preoperatively with a pseudo-3-dimensional model visualizing eloquent language, motor, and visual cortical and subcortical information. The early postoperative course was uneventful. At her 3-month follow-up visit, her language impairments had completely recovered. Additionally, magnetic resonance imaging demonstrated complete collapse of the arachnoid cyst. The combination of nTMS and tractography supports the identification of a safe trajectory for cystoventriculostomy in eloquent arachnoid cysts. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. A reliable and safe gastrotomy closure technique assessed in a porcine survival model pilot study: success of the Queen's closure.

    PubMed

    Hookey, L C; Bielawska, B; Samis, A; Jalink, D; Ellis, R; Khokhotva, V; Hurlbut, D; Mercer, D

    2009-06-01

    The evolution of NOTES to clinical implementation has been hampered by lack of a reliable, safe, and easy-to-implement technique for closure of the opening created in accessing the peritoneum. The Queen's closure uses a combination of endoscopic clips and loop devices to seal such defects in the stomach wall. This study aimed to assess the Queen's closure in a porcine survival model. Five 30-kg pigs underwent endoscopic transgastric surgery with exploration of the peritoneum. The endoscope was then withdrawn back into the stomach and the closure performed. The animals were recovered, monitored closely, and underwent endoscopy 1 week after surgery. They were then euthanized at 2 (n = 2) and 3 (n = 3) weeks after surgery with subsequent necropsy. The mean procedure time (from intubation of the esophagus to withdrawal of the endoscope) was 79 minutes (range 45-105 minutes) with a mean time of exploration of the peritoneum of 14 minutes (range 8-25 minutes). All animals recovered well with no apparent pain, distress, or signs of infection. Endoscopic examination 1 week after surgery revealed all the closures to be intact and only identifiable by a small ulcer. At necropsy, the gastrotomy site was identifiable only by minor serosal adhesions. Histological study demonstrated full-thickness closure with minimal inflammation. The Queen's closure is a reliable and safe technique that provides full-thickness gastrotomy closure without any observed complications. The technique has proven to be transferable knowledge that holds promise for clinical implementation.

  19. Cecal intubation rates in different eras of endoscopic technological development

    PubMed Central

    Pasternak, Artur; Szura, Mirosław; Pędziwiatr, Michał; Major, Piotr; Rembiasz, Kazimierz

    2018-01-01

    Introduction Colonoscopy plays a critical role in colorectal cancer (CRC) screening and has been widely regarded as the gold standard. Cecal intubation rate (CIR) is one of the well-defined quality indicators used to assess colonoscopy. Aim To assess the impact of new technologies on the quality of colonoscopy by assessing completion rates. Material and methods This was a dual-center study at the 2nd Department of Surgery at Jagiellonian University Medical College and at the Specialist Center “Medicina” in Krakow, Poland. The CIR and cecal intubation time (CIT) in three different eras of technological advancement were determined. The study enrolled 27 463 patients who underwent colonoscopy as part of a national CRC screening program. The patients were divided into three groups: group I – 3408 patients examined between 2000 and 2003 (optical endoscopes); group II – 10 405 patients examined between 2004 and 2008 (standard electronic endoscopes); and group III – 13 650 patients examined between 2009 and 2014 (modern endoscopes). Results There were statistically significant differences in the CIR between successive eras. The CIR in group I (2000–2003) was 69.75%, in group II (2004–2008) was 92.32%, and in group III (2009–2014) was 95.17%. The mean CIT was significantly reduced in group III. Conclusions Our study shows that the technological innovation of novel endoscopy devices has a great influence on the effectiveness of the CRC screening program. The new era of endoscopic technological development has the potential to reduce examination-related patient discomfort, obviate the need for sedation and increase diagnostic yields. PMID:29643961

  20. A wireless power transmission system for an active capsule endoscope for colon inspection.

    PubMed

    Jia, Zhiwei; Yan, Guozheng; Shi, Yu; Zhu, Bingquan

    2012-07-01

    Multipurpose active capsule endoscopes (ACE) have drawn considerable attention in recent years, but these devices continue to suffer from energy limitations. In order to deliver stable and sufficient energy safely, a wireless power transmission system based on inductive coupling is presented. The system consists of a double-layer solenoid pair primary coil outside and a multiple secondary coils inside the body. At least 500 mW usable power can be transmitted under the worst geometrical conditions and the safety restraints in a volume of Φ13 × 13 mm. The wireless power transmission system is integrated to an ACE and applied in animal experiments. The designed wireless power transmission is proved to be feasible and potentially safe in a future application.

  1. Effective palliation for advanced esophageal cancer using intralumenal irradiation.

    PubMed

    Makarewicz, R; Czechowicz, W; Kabacińska, R

    1996-01-01

    Palliative treatment by intracavitary irradiation alone has been used in 15 patients with advanced carcinoma of the esophagus. Most of them had already failed other palliative modalities including external irradiation, chemoradiotherapy, laserotherapy and dilatation. Intracavitary irradiation was carried out with a microSelectron HDR afterloading device and usually 22.5 Gy was given in three fractions repeated weekly. Up to three month after treatment, complete endoscopic regression was seen in 1 patient, partial endoscopic regression in 8 patients, no response in one and progressive disease in 5 patients. The median survival time is 6.2 months. There were not severe complications. We conclude that high dose rate intracavitary irradiation is a useful palliative modality in patients with advanced or recurrent esophageal cancer.

  2. Optical coherence tomography in the diagnosis of dysplasia and adenocarcinoma in Barret's esophagus

    NASA Astrophysics Data System (ADS)

    Gladkova, N. D.; Zagaynova, E. V.; Zuccaro, G.; Kareta, M. V.; Feldchtein, F. I.; Balalaeva, I. V.; Balandina, E. B.

    2007-02-01

    Statistical analysis of endoscopic optical coherence tomography (EOCT) surveillance of 78 patients with Barrett's esophagus (BE) is presented in this study. The sensitivity of OCT device in retrospective open detection of early malignancy (including high grade dysplasia and intramucosal adenocarcinoma (IMAC)) was 75%, specificity 82%, diagnostic accuracy - 80%, positive predictive value- 60%, negative predictive value- 87%. In the open recognition of IMAC sensitivity was 81% and specificity were 85% each. Results of a blind recognition with the same material were similar: sensitivity - 77%, specificity 85%, diagnostic accuracy - 82%, positive predictive value- 70%, negative predictive value- 87%. As the endoscopic detection of early malignancy is problematic, OCT holds great promise in enhancing the diagnostic capability of clinical GI endoscopy.

  3. A Look from the Inside

    NASA Technical Reports Server (NTRS)

    2004-01-01

    NASA's Hubble Space Telescope has given the world amazing images of the distant stars, planets, and galaxies. The cutting-edge imaging technology that enhances the Hubble images also extends its benefits to life here on Earth, from deciphering previously unreadable portions of the Dead Sea Scrolls to improving digital mammographies for advanced cancer detection. This imaging technology is now helping physicians to perform micro-invasive arthroscopic surgery, which is the visual examination of an interior joint such as the knee. In 1997, NASA's Glenn Research Center signed a Space Act Agreement with Micro Medical Devices, Inc. (MMD), a medical device engineering company that licenses miniature surgical devices. At that time, MMD was in the process of developing a new micro-endoscope. This tool enables surgeons to view what is happening inside the body on a screen, eliminating the need for a more invasive diagnostic procedure. The images from the micro-endoscope needed to be extremely clear, a challenge with the tool s small size. The images also needed to be viewed in real time to allow surgeons to see what was happening in the body at that very moment. MMD established Clear Image Technology, LLC, of Elyria, Ohio, to commercialize the miniature endoscope. Clear Image Technology then partnered with Arthrotek, Inc., a sports medicine subsidiary of Biomet, Inc., to introduce the tool to the commercial market as the InnerVue[TM] Diagnostic Scope System. The InnerVue system is designed for use in a diagnostic environment, such as an office or outpatient service, to evaluate conditions within a joint. While the InnerVue scope is primarily being applied to the knee and shoulder, other small joints such as the wrist, elbow, and ankle are being investigated. A physician can use the system alone or in conjunction with magnetic resonance imaging (MRI) to determine the next treatment step for each patient. The procedure can be more accurate than MRI, particularly with diagnosing cartilage and articular surface damage and assessing arthritis severity.

  4. MOEMS optical delay line for optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Choudhary, Om P.; Chouksey, S.; Sen, P. K.; Sen, P.; Solanki, J.; Andrews, J. T.

    2014-09-01

    Micro-Opto-Electro-Mechanical optical coherence tomography, a lab-on-chip for biomedical applications is designed, studied, fabricated and characterized. To fabricate the device standard PolyMUMPS processes is adopted. We report the utilization of electro-optic modulator for a fast scanning optical delay line for time domain optical coherence tomography. Design optimization are performed using Tanner EDA while simulations are performed using COMSOL. The paper summarizes various results and fabrication methodology adopted. The success of the device promises a future hand-held or endoscopic optical coherence tomography for biomedical applications.

  5. A systematic review of biodegradable biliary stents: promising biocompatibility without stent removal.

    PubMed

    Siiki, Antti; Sand, Juhani; Laukkarinen, Johanna

    2018-05-18

    Biodegradable self-expanding stents are an emerging alternative to standard biliary stents as the development of endoscopic insertion devices advances. The aim was to systematically review the existing literature on biodegradable biliary stents. In-vivo studies on the use of biodegradable stents in the biliary duct were systematically reviewed from 1990 to 2017. Despite extensive research on the biocompatibility of stents, the experience so far on their clinical use is limited. A few favorable reports have recently been presented on endoscopically and percutaneously inserted self-expanding biodegradable polydioxanone stents in benign biliary strictures. Another potential indication appears to be postcholecystectomy leak of the cystic duct. The main benefit of biodegradable stents is that stent removal can be avoided. The biocompatibility of the current biodegradable stent materials, most prominently polydioxanone, is well documented. In the few studies currently available, biodegradable stents are reported to be feasible and safe, also in humans. The initial results of the endoscopic use of these stents in benign biliary stricture management and for treating postcholecystectomy bile leaks are promising. Further controlled studies on long-term clinical results and cost-effectiveness are needed.

  6. Recent advances in endovascular techniques for management of acute nonvariceal upper gastrointestinal bleeding

    PubMed Central

    Loffroy, Romaric F; Abualsaud, Basem A; Lin, Ming D; Rao, Pramod P

    2011-01-01

    Over the past two decades, transcatheter arterial embolization has become the first-line therapy for the management of upper gastrointestinal bleeding that is refractory to endoscopic hemostasis. Advances in catheter-based techniques and newer embolic agents, as well as recognition of the effectiveness of minimally invasive treatment options, have expanded the role of interventional radiology in the management of hemorrhage for a variety of indications, such as peptic ulcer bleeding, malignant disease, hemorrhagic Dieulafoy lesions and iatrogenic or trauma bleeding. Transcatheter interventions include the following: selective embolization of the feeding artery, sandwich coil occlusion of the gastroduodenal artery, blind or empiric embolization of the supposed bleeding vessel based on endoscopic findings and coil pseudoaneurysm or aneurysm embolization by three-dimensional sac packing with preservation of the parent artery. Transcatheter embolization is a fast, safe and effective, minimally invasive alternative to surgery when endoscopic treatment fails to control bleeding from the upper gastrointestinal tract. This article reviews the various transcatheter endovascular techniques and devices that are used in a variety of clinical scenarios for the management of hemorrhagic gastrointestinal emergencies. PMID:21860697

  7. Therapeutic aspects of endoscopic ultrasound

    NASA Astrophysics Data System (ADS)

    Woodward, Timothy A.

    1999-06-01

    Endoscopic ultrasound (EUS) is a technology that had been used primarily as a passive imaging modality. Recent advances have enabled us to move beyond the use of EUS solely as a staging tool to an interventional device. Current studies suggest that interventional applications of EUS will allow for minimally invasive assessment and therapies in a cost-effective manner. Endoscopic ultrasound with fine needle aspiration (EUS-FNA) has been demonstrated to be a technically feasible, relatively safe method of obtaining cytologic specimens. The clinical utility of EUS- FNA appears to be greatest in the diagnosis and staging of pancreatic cancer and in the nodal staging of gastrointestinal and pulmonary malignancies. In addition, EUS-FNA has demonstrated utility in the sampling pleural and ascitic fluid not generally appreciated or assessable to standard interventions. Interventional applications of EUS include EUS-guided pseudocyst drainage, EUS-guided injection of botulinum toxin in the treatment of achalasia, and EUS- guided celiac plexus neurolysis in the treatment of pancreatic cancer pain. Finally, EUS-guided fine-needle installation is being evaluated, in conjunction with recent bimolecular treatment modalities, as a delivery system in the treatment of certain gastrointestinal tumors.

  8. Stenosis of esophago-jejuno anastomosis after gastric surgery.

    PubMed

    Fukagawa, Takeo; Gotoda, Takuji; Oda, Ichiro; Deguchi, Yasunori; Saka, Makoto; Morita, Shinji; Katai, Hitoshi

    2010-08-01

    Stenosis of esophago-jejuno anastomosis is one of the postoperative complications of gastric surgery. This complication usually manifests with the symptom of dysphagia and is treated by endoscopic dilatation. No large-scale studies have been conducted to determine the incidence of this complication after surgery. The data of a total of 1478 consecutive patients who underwent total, proximal, or completion gastrectomy, including esophago-jejuno anastomosis, between 2000 and 2008 were analyzed retrospectively with a view to determining the incidence of anastomotic stenosis. Sixty patients (4.1%) developed stenosis of the esophago-jejuno anastomosis which needed to be treated by endoscopic balloon dilatation. The average interval between the surgery and detection of stenosis was 67.4 days (median = 58.0). Multivariate analysis identified female gender, proximal gastrectomy, use of a narrow-sized stapler, and the choice of the stapling device as significant factors influencing the risk of development of anastomotic stenosis. Esophago-jejuno anastomotic stenosis appears to be a common late postoperative complication after gastric surgery. Endoscopic examination and treatment yielded favorable outcomes in patients complaining of dysphagia after gastric surgery.

  9. Accuracy of endoscopic ultrasonography for diagnosing ulcerative early gastric cancers

    PubMed Central

    Park, Jin-Seok; Kim, Hyungkil; Bang, Byongwook; Kwon, Kyesook; Shin, Youngwoon

    2016-01-01

    Abstract Although endoscopic ultrasonography (EUS) is the first-choice imaging modality for predicting the invasion depth of early gastric cancer (EGC), the prediction accuracy of EUS is significantly decreased when EGC is combined with ulceration. The aim of present study was to compare the accuracy of EUS and conventional endoscopy (CE) for determining the depth of EGC. In addition, the various clinic-pathologic factors affecting the diagnostic accuracy of EUS, with a particular focus on endoscopic ulcer shapes, were evaluated. We retrospectively reviewed data from 236 consecutive patients with ulcerative EGC. All patients underwent EUS for estimating tumor invasion depth, followed by either curative surgery or endoscopic treatment. The diagnostic accuracy of EUS and CE was evaluated by comparing the final histologic result of resected specimen. The correlation between accuracy of EUS and characteristics of EGC (tumor size, histology, location in stomach, tumor invasion depth, and endoscopic ulcer shapes) was analyzed. Endoscopic ulcer shapes were classified into 3 groups: definite ulcer, superficial ulcer, and ill-defined ulcer. The overall accuracy of EUS and CE for predicting the invasion depth in ulcerative EGC was 68.6% and 55.5%, respectively. Of the 236 patients, 36 patients were classified as definite ulcers, 98 were superficial ulcers, and 102 were ill-defined ulcers, In univariate analysis, EUS accuracy was associated with invasion depth (P = 0.023), tumor size (P = 0.034), and endoscopic ulcer shapes (P = 0.001). In multivariate analysis, there is a significant association between superficial ulcer in CE and EUS accuracy (odds ratio: 2.977; 95% confidence interval: 1.255–7.064; P = 0.013). The accuracy of EUS for determining tumor invasion depth in ulcerative EGC was superior to that of CE. In addition, ulcer shape was an important factor that affected EUS accuracy. PMID:27472672

  10. Locoregional mitomycin C injection for esophageal stricture after endoscopic submucosal dissection.

    PubMed

    Machida, H; Tominaga, K; Minamino, H; Sugimori, S; Okazaki, H; Yamagami, H; Tanigawa, T; Watanabe, K; Watanabe, T; Fujiwara, Y; Arakawa, T

    2012-06-01

    This prospective study aimed to evaluate the feasibility and safety of locoregional mitomycin C (MMC) injection to treat refractory esophageal strictures after endoscopic submucosal dissection (ESD) for superficial esophageal carcinoma. Patients with dysphagia and strictures that were refractory to repeated endoscopic balloon dilation (EBD) were eligible. After EBD, MMC was injected into the dilated site. Between June 2009 and August 2010, five patients were recruited. The treatment was performed once in two patients and twice in three patients with recurrent dysphagia or restenosis. In all patients, passing a standard endoscope through the site was easy and the dysphagia grade improved (grade 3→1 in 3 patients, grade 4→2 in 2 patients). No serious complications were noted. During the observation period of 4.8 months, neither recurrent dysphagia nor re-stricture appeared in any of the patients. The combination of locoregional MMC injections and EBD is feasible and safe for the treatment of esophageal strictures after ESD.Recently, endoscopic submucosal dissection (ESD) has been developed and accepted as a new endoscopic treatment for gastrointestinal tumors. ESD is a promising treatment for superficial esophageal carcinoma (SEC), and it has a reliable en bloc resection rate. However, the application of ESD for widespread lesions is challenging because of the high risk of the development of severe strictures, which lead to a low quality of life after ESD. Although endoscopic balloon dilation (EBD) is effective for benign strictures, it needs to be performed frequently until the dysphagia disappears 1. Mitomycin C (MMC), which is a chemotherapeutic agent derived from some Streptomyces species 2, reduces scar formation when topically applied to a surgical lesion. MMC has been applied to treat strictures in a variety of anatomical locations, including a variety of organs 3. The aim of this study was to prospectively evaluate both the feasibility and the safety of locoregional MMC injection therapy in patients with refractory esophageal strictures after ESD for SEC. © Georg Thieme Verlag KG Stuttgart · New York.

  11. Transforaminal Endoscopic Decompression for a Giant Epidural Gas-Containing Pseudocyst: A Case Report and Literature Review.

    PubMed

    Zhu, Bin; Jiang, Liang; Liu, Xiao Guang

    2017-03-01

    The isolated epidural gas-containing pseudocyst is an uncommon pathogenic factor for severe pain of the lower limb as a result of nerve root compression. After reviewing these rare cases reported in the literature, we found that the name, pathogenesis, and treatment strategy of this pathology remained controversial. The most common treatment is conservative treatment or percutaneous aspiration which might result inpoor pain relief and high recurrence rates. Moreover, the patient who received open surgery had good clinical outcome; however, he or she might experience a significant soft tissue injury.In this study, we report the first case of a patient who had a giant epidural gas-containing pseudocyst and received percutaneous endoscopic surgery. This 57-year-old man had been complaining of severe radicular pain in his right ankle for one year. According to computed tomography (CT) and magnetic resonance imaging (MRI) prior to the surgery, the results showed an isolated epidural gas-containing pseudocyst was located in the right lateral recess of S1. At the last follow-up period, postoperative CT scan showed the gas-contained pseudocyst was completely resected and this patient was free from the pain.Due to the great advances in endoscopic techniques and equipment, it is easier to perform lumbar surgery through the endoscope. With this first case of percutaneous endoscopic treatment for the symptomatic epidural gas-containing pseudocyst reported in this study, we believe that this surgical method provides an option to treat this rare condition because it provides sufficient decompression, has a low recurrence rate, and is minimally invasive. Key words: Endoscopic surgery, pseudocyst, epidural gas, intraspinal gas, radiulopathy.

  12. Preoperative endoscopic titanium clip placement facilitates intraoperative localization of early-stage esophageal cancer or severe dysplasia.

    PubMed

    Tan, Lei; Feng, Juan; Zhao, Qin; Chen, Ping; Yang, Guotao

    2017-08-02

    Accurate intraoperative localization of esophageal lesions is essential for successful surgical resection. We tested whether preoperative endoscopic placement of titanium clips could facilitate intraoperative localization of early-stage esophageal cancer or severe dysplasia. A prospective randomized clinical trial was performed between May 2012 and July 2014. All enrolled patients received preoperative endoscopy and esophageal endoscopic ultrasound, as well as pathological study on the biopsy specimen, to confirm early stage esophageal cancer or severe dysplasia. One day before the surgical operation, patients in the experimental group received the preoperative endoscopic titanium labeling of esophageal lesions. Then, during the surgical operation, palpitation of titanium clips was used to localize the lesions in these patients. In patients in the control group, palpitation of nodules or esophageal wall mucosal thickening, together with the consideration of the results from preoperative endoscopic and ultrasound studies, was applied to estimate the location of the esophageal lesions. Study outcomes included the proportions of patients having successful intraoperative pre-resection lesion localization, post-esophagectomy lesion visualization, negative upper surgical margin, change of surgical approaches, and positive postoperative pathological diagnosis. A total of 27 patients were enrolled into the study, with 14 in the experimental group and 13 in the control group. Compared to the patients in the control group, a higher proportion of patients in the experimental group had statistically significant successful intraoperative esophageal lesion localization (100 versus 15.3% in the experimental versus control group). Preoperative endoscopic titanium clip placement could facilitate intraoperative localization of early-stage esophageal cancer or severe dysplasia. Current study was registered in Chinese Clinical Trial Registry and World Health Organization International Clinical Trials Registry Platform, ChiCTR-INR-17010949 . Registered 22 March 2017, retrospectively registered.

  13. Feasibility of Obtaining Quantitative 3-Dimensional Information Using Conventional Endoscope: A Pilot Study

    PubMed Central

    Hyun, Jong Jin; Keum, Bora; Seo, Yeon Seok; Kim, Yong Sik; Jeen, Yoon Tae; Lee, Hong Sik; Um, Soon Ho; Kim, Chang Duck; Ryu, Ho Sang; Lim, Jong-Wook; Woo, Dong-Gi; Kim, Young-Joong; Lim, Myo-Taeg

    2012-01-01

    Background/Aims Three-dimensional (3D) imaging is gaining popularity and has been partly adopted in laparoscopic surgery or robotic surgery but has not been applied to gastrointestinal endoscopy. As a first step, we conducted an experiment to evaluate whether images obtained by conventional gastrointestinal endoscopy could be used to acquire quantitative 3D information. Methods Two endoscopes (GIF-H260) were used in a Borrmann type I tumor model made of clay. The endoscopes were calibrated by correcting the barrel distortion and perspective distortion. Obtained images were converted to gray-level image, and the characteristics of the images were obtained by edge detection. Finally, data on 3D parameters were measured by using epipolar geometry, two view geometry, and pinhole camera model. Results The focal length (f) of endoscope at 30 mm was 258.49 pixels. Two endoscopes were fixed at predetermined distance, 12 mm (d12). After matching and calculating disparity (v2-v1), which was 106 pixels, the calculated length between the camera and object (L) was 29.26 mm. The height of the object projected onto the image (h) was then applied to the pinhole camera model, and the result of H (height and width) was 38.21 mm and 41.72 mm, respectively. Measurements were conducted from 2 different locations. The measurement errors ranged from 2.98% to 7.00% with the current Borrmann type I tumor model. Conclusions It was feasible to obtain parameters necessary for 3D analysis and to apply the data to epipolar geometry with conventional gastrointestinal endoscope to calculate the size of an object. PMID:22977798

  14. Malory-Weis syndrome based on own experience - diagnostics and modern principles of management.

    PubMed

    Cybułka, Bartosz

    2016-03-01

    Every gastrointestinal bleeding is an immediate threat to life, requiring close supervision in a hospital setting and making it mandatory to perform verification and endoscopic intervention. In some cases of a dynamic course, in order to make up deficiencies, it is necessary to use blood and blood products. One of the causes of bleeding located proximally to the ligament of Treitz is damage to the mucous membrane and deeper layers of the gastroesophageal junction, called Mallory-Weiss syndrome. The aim of the study was retrospective analysis of a selected group of patients with symptomatic upper gastrointestinal bleeding in the course of Mallory-Weiss syndrome, identification of typical characteristics of this disease entity in the studied population as well as demonstration of the effectiveness of endoscopic treatment using argon plasma coagulation (APC). The analysis included 2120 gastroscopy results, with 111 (5.24%) examinations conducted due to symptomatic gastrointestinal bleeding. In the studied group, endoscopic diagnosis of Mallory-Weiss syndrome was made in 22 patients (1.04%). The studied disease entity was the cause of upper gastrointestinal bleeding in 19.82% of cases. Although this condition is usually characterised by a mild and self-limiting course, 59.09% of patients in the studied group required therapeutic endoscopic intervention due to active bleeding. In 54.55%, argon plasma coagulation was successfully used to control the source of bleeding. Early gastroscopy, which remains both a diagnostic and therapeutic intervention, guarantees effective control of the clinical course of Mallory-Weiss syndrome. Endoscopic argon plasma coagulation is an effective way to treat bleeding, used in endoscopic monotherapy or in combination with other procedures.

  15. Evaluation of an endoscopically assisted gastropexy technique in dogs.

    PubMed

    Dujowich, Mauricio; Reimer, S Brent

    2008-04-01

    To evaluate the use of endoscopy in conjunction with a gastropexy technique in dogs as a potential means to aid prevention of gastric dilatation-volvulus. 12 healthy adult medium- and large-breed dogs. 12 adult research dogs that had no abnormal physical examination findings each underwent an endoscopically assisted gastropexy procedure. On completion of the procedure, the dogs were euthanized and exploratory laparotomies were performed to evaluate the surgical site. Data recorded included anatomic location of the gastropexy, gastropexy length, and duration of procedure as well as any complications. Mean+/-SD gastropexy length was 3.3+/-0.25 cm, and mean duration of surgery was 18+/-7 minutes. In each dog, the stomach was located in its normal anatomic position and all gastropexies were sutured to the abdominal wall at the level of the pyloric antrum. The only complications during the procedure were needle bending and breakage at the time of stay suture placement. On the basis of these findings, it appears that endoscopically assisted gastropexy is a simple, fast, safe, and reliable method of performing a prophylactic gastropexy in dogs when undertaken by a person who is skilled in endoscopy. Such a procedure maximizes the benefits of decreased morbidity and shorter duration of anesthesia associated with minimally invasive surgery. Further clinical studies are warranted to evaluate the long-term efficacy of this procedure in dogs at risk for development of gastric dilatation-volvulus.

  16. Direct endoscopic video registration for sinus surgery

    NASA Astrophysics Data System (ADS)

    Mirota, Daniel; Taylor, Russell H.; Ishii, Masaru; Hager, Gregory D.

    2009-02-01

    Advances in computer vision have made possible robust 3D reconstruction of monocular endoscopic video. These reconstructions accurately represent the visible anatomy and, once registered to pre-operative CT data, enable a navigation system to track directly through video eliminating the need for an external tracking system. Video registration provides the means for a direct interface between an endoscope and a navigation system and allows a shorter chain of rigid-body transformations to be used to solve the patient/navigation-system registration. To solve this registration step we propose a new 3D-3D registration algorithm based on Trimmed Iterative Closest Point (TrICP)1 and the z-buffer algorithm.2 The algorithm takes as input a 3D point cloud of relative scale with the origin at the camera center, an isosurface from the CT, and an initial guess of the scale and location. Our algorithm utilizes only the visible polygons of the isosurface from the current camera location during each iteration to minimize the search area of the target region and robustly reject outliers of the reconstruction. We present example registrations in the sinus passage applicable to both sinus surgery and transnasal surgery. To evaluate our algorithm's performance we compare it to registration via Optotrak and present closest distance point to surface error. We show our algorithm has a mean closest distance error of .2268mm.

  17. Endoscopic Features of Mucous Cap Polyps: A Way to Predict Serrated Polyps.

    PubMed

    Moy, Brian T; Forouhar, Faripour; Kuo, Chia-Ling; Devers, Thomas J

    2018-04-27

    The aims of the study were to identify whether a mucous-cap predicts the presence of serrated polyps, and to determine whether additional endoscopic findings predict the presence of a sessile serrated adenomas/polyp (SSA/P). We analyzed 147 mucous-capped polyps with corresponding histology, during 2011-2014. Eight endoscopic features (presence of borders, elevation, rim of debris, location in the colon, size ≥10 mm, varicose vessels, nodularity, and alteration in mucosal folds) of mucous-capped polyps were examined to see if they can predict SSA/Ps. A total of 86% (n=126) of mucous-capped polyps were from the right sided serrated pathway (right-sided hyperplastic [n=83], SSA/Ps [n=43], traditional serrated adenoma [n=1]), 10% (n=15) were left-sided hyperplastic polyps, and 3% (n=5) were from the adenoma-carcinoma sequence. The presence of a mucous cap combined with varicose vessels was the only significant predictor for SSA/Ps. The other seven characteristics were not found to be statistically significant for SSA/Ps, although location in the colon and the presence of nodularity trended towards significance. Our study suggests that mucous-capped polyps have high predictability for being a part of the serrated pathway. Gastroenterologists should be alert for a mucous-capped polyp with varicose veins, as these lesions have a higher risk of SSA/P.

  18. Microsurgical and Endoscopic Anatomy for Intradural Temporal Bone Drilling and Applications of the Electromagnetic Navigation System: Various Extensions of the Retrosigmoid Approach.

    PubMed

    Matsushima, Ken; Komune, Noritaka; Matsuo, Satoshi; Kohno, Michihiro

    2017-07-01

    The use of the retrosigmoid approach has recently been expanded by several modifications, including the suprameatal, transmeatal, suprajugular, and inframeatal extensions. Intradural temporal bone drilling without damaging vital structures inside or beside the bone, such as the internal carotid artery and jugular bulb, is a key step for these extensions. This study aimed to examine the microsurgical and endoscopic anatomy of the extensions of the retrosigmoid approach and to evaluate the clinical feasibility of an electromagnetic navigation system during intradural temporal bone drilling. Five temporal bones and 8 cadaveric cerebellopontine angles were examined to clarify the anatomy of retrosigmoid intradural temporal bone drilling. Twenty additional cerebellopontine angles were dissected in a clinical setting with an electromagnetic navigation system while measuring the target registration errors at 8 surgical landmarks on and inside the temporal bone. Retrosigmoid intradural temporal bone drilling expanded the surgical exposure to allow access to the petroclival and parasellar regions (suprameatal), internal acoustic meatus (transmeatal), upper jugular foramen (suprajugular), and petrous apex (inframeatal). The electromagnetic navigation continuously guided the drilling without line of sight limitation, and its small devices were easily manipulated in the deep and narrow surgical field in the posterior fossa. Mean target registration error was less than 0.50 mm during these procedures. The combination of endoscopic and microsurgical techniques aids in achieving optimal exposure for retrosigmoid intradural temporal bone drilling. The electromagnetic navigation system had clear advantages with acceptable accuracy including the usability of small devices without line of sight limitation. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Clinical and histologic studies of olfactory outcomes after nasoseptal flap harvesting.

    PubMed

    Kim, Sang-Wook; Park, Kyung Bum; Khalmuratova, Roza; Lee, Hong-Kyoung; Jeon, Sea-Yuong; Kim, Dae Woo

    2013-07-01

    Since the introduction of an endonasal endoscopic approach in transsphenoidal pituitary surgery, reports of perioperative olfactory changes have presented conflicting results. We examined the incidence of olfactory loss in cases of endoscopic transsphenoidal pituitary surgery with skull base repair using the nasoseptal flap (NSF) and the effects of monopolar electrocautery commonly used in designing the NSF. Case-control study. Fifteen patients who underwent endoscopic transsphenoidal pituitary surgery with skull base reconstruction using the NSF were divided into cold knife (n = 8) and electrocautery (n = 7) groups according to the device used in the superior incision of the NSF. Patients were followed regularly to monitor the need for dressing or adhesiolysis around the olfactory cleft. All subjects received olfactory tests before and 6 months after surgery. Septal mucosa specimens obtained during posterior septectomy were incised with different devices, and the degree of mucosal damage was evaluated. One patient in the electrocautery group demonstrated olfactory dysfunction postoperatively, but the other 14 patients showed no decrease in olfaction. In histologic analyses, 55.8% and 76.9% of the mucosal surface showed total epithelial loss when the mucosa was cut with cutting- and coagulation-mode electrocautery, respectively. In contrast, only 20% of the mucosal surface exhibited total epithelial loss when the mucosa was cut with a cold knife (P < .01). Olfactory impairment is not common after use of the NSF. Use of the cold knife in making superior incision may reduce tissue damage with better olfactory outcomes. Copyright © 2013 The American Laryngological, Rhinological and Otological Society, Inc.

  20. Virtual reality training for endoscopic surgery: voluntary or obligatory?

    PubMed

    van Dongen, K W; van der Wal, W A; Rinkes, I H M Borel; Schijven, M P; Broeders, I A M J

    2008-03-01

    Virtual reality (VR) simulators have been developed to train basic endoscopic surgical skills outside of the operating room. An important issue is how to create optimal conditions for integration of these types of simulators into the surgical training curriculum. The willingness of surgical residents to train these skills on a voluntary basis was surveyed. Twenty-one surgical residents were given unrestricted access to a VR simulator for a period of four months. After this period, a competitive element was introduced to enhance individual training time spent on the simulator. The overall end-scores for individual residents were announced periodically to the full surgical department, and the winner was awarded a prize. In the first four months of study, only two of the 21 residents (10%) trained on the simulator, for a total time span of 163 minutes. After introducing the competitive element the number of trainees increased to seven residents (33%). The amount of training time spent on the simulator increased to 738 minutes. Free unlimited access to a VR simulator for training basic endoscopic skills, without any form of obligation or assessment, did not motivate surgical residents to use the simulator. Introducing a competitive element for enhancing training time had only a marginal effect. The acquisition of expensive devices to train basic psychomotor skills for endoscopic surgery is probably only effective when it is an integrated and mandatory part of the surgical curriculum.

  1. Endoscopic closure of an iatrogenic rupture of upper esophagus (Lannier’s triangle) with the use of endoclips – case report and review of the literature

    PubMed Central

    Mantzoukis, Konstantinos; Papadimitriou, Kassiani; Kouvelis, Ioannis; Theocharidou, Athina; Zebekakis, Pantelis; Vital, Victor; Nikolaidis, Pavlos; Germanidis, Georgios

    2011-01-01

    We present a case report regarding a 74-year-old male with iatrogenic esophageal perforation, after an attempt to remove a food bolus impaction at Lannier’s triangle (proximal esophagus). The perforation was treated endoscopically (flexible EGD) by clip application in two sessions, with excellent outcome. Esophageal perforations occur rarely, usually following a medical procedure. The clinical manifestations are often insidious with potentially catastrophic complications. Although the majority of cases have been treated conservatively and/or operatively over the years, there is a rising tendency for non-operative endoscopic interventions due to the high morbidity and mortality rates seen even in specialized units. For this reason self-expandable stents, endoclips, tissue sealants and suturing devices have been used. A high degree of clinical suspicion is essential for successful management of esophageal perforations, as is early decision to intervene and respect for basic surgical principles such as prevention and limitation of extraesophageal contamination, prevention of reflux of gastric contents and restoration of gastrointestinal tract integrity. The published reports on the use of endoclips for repairing perforations of the proximal esophagus are rare. To our knowledge, this is the first case report regarding the endoscopic application of endoclips for the successful closure of an iatrogenic perforation at Lannier’s triangle. PMID:24714287

  2. Diagnostic and therapeutic direct peroral cholangioscopy using an intraductal anchoring balloon

    PubMed Central

    Parsi, Mansour A; Stevens, Tyler; Vargo, John J

    2012-01-01

    AIM: To report our experience using a recently introduced anchoring balloon for diagnostic and therapeutic direct peroral cholangioscopy (DPOC). METHODS: Consecutive patients referred for diagnostic or therapeutic peroral cholangioscopy were evaluated in a prospective cohort study. The patients underwent DPOC using an intraductal anchoring balloon, which was recently introduced to allow consistent access to the biliary tree with an ultraslim upper endoscope. The device was later voluntarily withdrawn from the market by the manufacturer. RESULTS: Fourteen patients underwent DPOC using the anchoring balloon. Biliary access with an ultraslim upper endoscope was accomplished in all 14 patients. In 12 (86%) patients, ductal access required sphincteroplasty with a 10-mm dilating balloon. Intraductal placement of the ultraslim upper endoscope allowed satisfactory visualization of the biliary mucosa to the level of the confluence of the right and left hepatic ducts in 13 of 14 patients (93%). Therapeutic interventions by DPOC were successfully completed in all five attempted cases (intraductal biopsy in one and DPOC guided laser lithotripsy in four). Adverse events occurred in a patient on immunosuppressive therapy who developed an intrahepatic biloma at the site of the anchoring balloon. This required hospitalization and antibiotics. Repeat endoscopic retrograde cholangiopancreatography 8 wk after the index procedure showed resolution of the biloma. CONCLUSION: Use of this anchoring balloon allowed consistent access to the biliary tree for performance of diagnostic and therapeutic DPOC distal to the biliary bifurcation. PMID:22912549

  3. Diagnostic and therapeutic direct peroral cholangioscopy using an intraductal anchoring balloon.

    PubMed

    Parsi, Mansour A; Stevens, Tyler; Vargo, John J

    2012-08-14

    To report our experience using a recently introduced anchoring balloon for diagnostic and therapeutic direct peroral cholangioscopy (DPOC). Consecutive patients referred for diagnostic or therapeutic peroral cholangioscopy were evaluated in a prospective cohort study. The patients underwent DPOC using an intraductal anchoring balloon, which was recently introduced to allow consistent access to the biliary tree with an ultraslim upper endoscope. The device was later voluntarily withdrawn from the market by the manufacturer. Fourteen patients underwent DPOC using the anchoring balloon. Biliary access with an ultraslim upper endoscope was accomplished in all 14 patients. In 12 (86%) patients, ductal access required sphincteroplasty with a 10-mm dilating balloon. Intraductal placement of the ultraslim upper endoscope allowed satisfactory visualization of the biliary mucosa to the level of the confluence of the right and left hepatic ducts in 13 of 14 patients (93%). Therapeutic interventions by DPOC were successfully completed in all five attempted cases (intraductal biopsy in one and DPOC guided laser lithotripsy in four). Adverse events occurred in a patient on immunosuppressive therapy who developed an intrahepatic biloma at the site of the anchoring balloon. This required hospitalization and antibiotics. Repeat endoscopic retrograde cholangiopancreatography 8 wk after the index procedure showed resolution of the biloma. Use of this anchoring balloon allowed consistent access to the biliary tree for performance of diagnostic and therapeutic DPOC distal to the biliary bifurcation.

  4. New endoscopic "scissors" to treat Zenker's diverticulum (with video).

    PubMed

    Ramchandani, Mohan; Nageshwar Reddy, D

    2013-10-01

    Zenker's diverticulum (ZD) is a rare disorder but is associated with significant morbidity. Cricopharyngeal (CP) myotomy is the mainstay of treatment, and various flexible endoscopic techniques have been used for division of the septum. However, there is a constant need for improvement in accessories. To evaluate the safety and effectiveness of a new electrocautery endoscopic scissor for CP myotomy in patients with symptomatic ZD. Observational human study. Tertiary-care hospital. This study involved 3 patients with symptomatic ZD. Flexible endoscopic CP myotomy was performed by using a novel scissors-type grasping device. CP myotomy involved 4 steps: (1) opening of the forceps, (2) grasping the muscle fiber, (3) closure of the forceps with application of gentle traction, and (4) dissection of muscle fibers by using cutting current. Intraprocedural bleeding was controlled with the same instrument by grasping vessels and applying coagulation current. Overall feasibility and performance, procedure time to achieve complete CP myotomy. CP myotomy was successfully performed in all patients. Mean procedure time was 10.6 minutes. There were no major adverse events. Minor intraprocedure bleeding occurred in 1 patient. Single arm, limited number of patients. The new instrument has potential advantages in comparison with standard instruments used for CP myotomy. The advantages of this new technique are better control of cutting and hemostatic abilities. Copyright © 2013 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  5. Systematic review of giant gastric lipomas reported since 1980 and report of two new cases in a review of 117110 esophagogastroduodenoscopies

    PubMed Central

    Cappell, Mitchell S; Stevens, Charlton E; Amin, Mitual

    2017-01-01

    AIM To systematically review the syndrome of giant gastric lipomas, report 2 new illustrative cases. METHODS Literature systematically reviewed using PubMed for publications since 1980 with following medical subject heading/keywords: (“giant lipoma”) AND (“gastric”) OR [(“lipoma”) and (“gastric”) and (“bleeding”)]. Two authors independently reviewed literature, and decided by consensus which articles to incorporate. Computerized review of pathology/endoscopy records at William Beaumont Hospitals, Royal Oak and Troy, Michigan, January 2005-December 2015, revealed 2 giant gastric lipomas among 117110 consecutive esophagogastroduodenoscopies (EGDs), which were thoroughly reviewed, including re-review of original endoscopic photographs, radiologic images, and pathologic slides. RESULTS Giant gastric lipomas are extremely rare: 32 cases reported since 1980, and 2 diagnosed among 117110 consecutive EGDs. Average patient age = 54.5 ± 17.0 years old (males = 22, females = 10). Maximal lipoma dimension averaged 7.9 cm ± 4.1 cm. Ulcerated mass occurred in 21 patients. Lipoma locations: antrum-17, body-and-antrum-4, antrum-intussuscepting-into-small-intestine-3, body-2, fundus-1, and unspecified-5. Intramural locations included submucosal-22, subserosal-2, and unspecified-8. Presentations included: acute upper gastrointestinal (UGI) bleeding-19, abdominal pain-5, nausea/vomiting-5, and asymptomatic-3. Symptoms among patients with UGI bleeding included: weakness/fatigue-6, abdominal pain-4, nausea/vomiting-4, early-satiety-3, dizziness-2, and other-1. Their hemoglobin on admission averaged 7.5 g/dL ± 2.8 g/dL. Patients with GI bleeding had significantly more frequently ulcers than other patients. EGD was extremely helpful diagnostically (n = 31 patients), based on characteristic endoscopic findings, including yellowish hue, well-demarcated margins, smooth overlying mucosa, and endoscopic cushion, tenting, or naked-fat signs. However, endoscopic mucosal biopsies were mostly non-diagnostic (11 of 12 non-diagnostic). Twenty (95%) of 21 abdominal CTs demonstrated characteristic findings of lipomas, including: well-circumscribed, submucosal, and homogeneous mass with attenuation of fat. Endoscopic-ultrasound showed characteristic findings in 4 (80%) of 5 cases: hyperechoic, well-localized, mass in gastric-wall-layer-3. Transabdominal ultrasound and UGI series were generally less helpful. All 32 patients underwent successful therapy without major complications or mortality, including: laparotomy and full-thickness gastric wall resection of tumor using various surgical reconstructions-26; laparotomy-and-enucleation-2; laparoscopic-transgastric-resection-2; endoscopic-mucosal-resection-1, and other-1. Two new illustrative patients are reported who presented with severe UGI bleeding from giant, ulcerated, gastric lipomas. CONCLUSION This systematic review may help standardize the endoscopic and radiologic evaluation and therapy of patients with this syndrome. PMID:28852321

  6. Intraoperative endoscopic ultrasound guidance for laparoscopic excision of invisible symptomatic deep intramural myomas.

    PubMed

    Urman, Bulent; Boza, Aysen; Ata, Baris; Aksu, Sertan; Arslan, Tonguc; Taskiran, Cagatay

    2018-01-01

    The aim of this study was to evaluate the feasibility of intraoperative endoscopic ultrasound guidance for excision of symptomatic deep intramural myomas that are not otherwise visible at laparoscopy. Seventeen patients with symptomatic deep intramural myomas who underwent laparoscopic myomectomy with intraoperative endoscopic ultrasound guidance were followed up and reported. All myomas were removed successfully. The endometrium was breached in one patient. All patients were relieved of their symptoms and three patients presenting with infertility conceived. There were no short- or long-term complications associated with the procedure. One patient who had multiple myomas necessitated intravenous iron treatment prior to discharge. Laparoscopic removal of small symptomatic deep intramural myomas is facilitated by the use of intraoperative endoscopic ultrasound that enables exact localisation and correct placement of the serosal incision. Impact statement What is already known on this subject: When the myoma is symptomatic, compressing the endometrium, does not show serosal protrusion and is not amenable to hysteroscopic resection, laparoscopic surgery may become challenging. What do the results of this study add: The use of intraoperative endoscopic ultrasound under these circumstances may facilitate the procedure by accurate identification of the myoma and correct placement of the serosal incision. What are the implications of these findings for clinical practice and/or further research: Intraoperative ultrasound should be more oftenly used to accurately locate deep intramural myomas to the end of making laparoscopy feasible and possibly decreasing recurrence by facilitating removal of otherwise unidentifiable disease.

  7. Percutaneous endoscopic holmium laser lithotripsy for management of complicated biliary calculi.

    PubMed

    Healy, Kelly; Chamsuddin, Abbas; Spivey, James; Martin, Louis; Nieh, Peter; Ogan, Kenneth

    2009-01-01

    Advances in endoscopic techniques have transformed the management of urolithiasis. We sought to evaluate the role of such urological interventions for the treatment of complex biliary calculi. We conducted a retrospective review of all patients (n=9) undergoing percutaneous holmium laser lithotripsy for complicated biliary calculi over a 4-year period (12/2003 to 12/2007). All previously failed standard techniques include ERCP with sphincterotomy (n=6), PTHC (n=7), or both of these. Access to the biliary system was obtained via an existing percutaneous transhepatic catheter or T-tube tracts. Endoscopic holmium laser lithotripsy was performed via a flexible cystoscope or ureteroscope. Stone clearance was confirmed intra- and post-operatively. A percutaneous transhepatic drain was left indwelling for follow-up imaging. Mean patient age was 65.6 years (range, 38 to 92). Total stone burden ranged from 1.7 cm to 5 cm. All 9 patients had stones located in the CBD, with 2 patients also having additional stones within the hepatic ducts. All 9 patients (100%) were visually stone-free after one endoscopic procedure. No major perioperative complications occurred. Mean length of stay was 2.4 days. At a mean radiological follow-up of 5.4 months (range, 0.5 to 21), no stone recurrence was noted. Percutaneous endoscopic holmium laser lithotripsy is a minimally invasive alternative to open salvage surgery for complex biliary calculi refractory to standard approaches. This treatment is both safe and efficacious. Success depends on a multidisciplinary approach.

  8. Percutaneous Endoscopic Holmium Laser Lithotripsy for Management of Complicated Biliary Calculi

    PubMed Central

    Healy, Kelly; Chamsuddin, Abbas; Spivey, James; Martin, Louis; Nieh, Peter

    2009-01-01

    Background and Objectives: Advances in endoscopic techniques have transformed the management of urolithiasis. We sought to evaluate the role of such urological interventions for the treatment of complex biliary calculi. Methods: We conducted a retrospective review of all patients (n=9) undergoing percutaneous holmium laser lithotripsy for complicated biliary calculi over a 4-year period (12/2003 to 12/2007). All previously failed standard techniques include ERCP with sphincterotomy (n=6), PTHC (n=7), or both of these. Access to the biliary system was obtained via an existing percutaneous transhepatic catheter or T-tube tracts. Endoscopic holmium laser lithotripsy was performed via a flexible cystoscope or ureteroscope. Stone clearance was confirmed intra- and postoperatively. A percutaneous transhepatic drain was left indwelling for follow-up imaging. Results: Mean patient age was 65.6 years (range, 38 to 92). Total stone burden ranged from 1.7 cm to 5 cm. All 9 patients had stones located in the CBD, with 2 patients also having additional stones within the hepatic ducts. All 9 patients (100%) were visually stone-free after one endoscopic procedure. No major perioperative complications occurred. Mean length of stay was 2.4 days. At a mean radiological follow-up of 5.4 months (range, 0.5 to 21), no stone recurrence was noted. Conclusions: Percutaneous endoscopic holmium laser lithotripsy is a minimally invasive alternative to open salvage surgery for complex biliary calculi refractory to standard approaches. This treatment is both safe and efficacious. Success depends on a multidisciplinary approach. PMID:19660213

  9. A specific role of endoscopic ultrasonography for therapeutic decision-making in patients with gastric cardia cancer.

    PubMed

    Park, Chan Hyuk; Park, Jun Chul; Chung, Hyunsoo; Shin, Sung Kwan; Lee, Sang Kil; Lee, Yong Chan

    2016-10-01

    The role of endoscopic ultrasonography (EUS) in gastric cardia cancer should be further evaluated because the accuracy of EUS depends on tumor location. We aimed to identify a specific role of EUS for therapeutic decision-making in patients with gastric cardia cancer. Initial EUS examinations for treatment-naïve gastric cancer that were followed by endoscopic resection or surgery were included in the study. Lesions were classified as cardiac and non-cardiac cancer according to tumor location. The diagnostic performance of EUS in predicting invasion depth was compared between the two groups. The overall accuracy of EUS in predicting invasion depth did not differ between the cardiac and non-cardiac cancer groups (44.4 vs. 52.3 %, P = 0.259). The underestimation rate was higher in the cardiac cancer group than in the non-cardiac cancer group (37.0 vs. 18.5 %, P = 0.001). When the depth of invasion was predicted to be deeper than the mucosa (submucosal or deeper) by EUS, the positive predictive value was 82.1 [95 % confidence interval (CI), 66.5-92.5 %] and 62.9 % (95 % CI, 60.5-66.9 %) in the cardiac and non-cardiac cancer groups, respectively (P = 0.015). In multivariable analysis, tumor location in the cardia was found to be an independent factor for the underestimation of invasion depth [odds ratio (95 % CI) = 2.242 (1.156-4.349)]. The underestimation rate in predicting invasion depth was significantly higher for cardiac cancers than for non-cardiac cancers. Therefore, selection of the treatment method for gastric cardia cancer via EUS should be done carefully.

  10. Transnasal endoscopic approach with powered instrumentation for treating squamous papilloma in the nasopharyngeal surface of the soft palate.

    PubMed

    Lee, J-H; Lee, Y-O; Lee, C-H; Cho, K-S

    2013-05-01

    To demonstrate a safe and effective method for complete resection of squamous papilloma in the nasopharyngeal surface of the soft palate. This technique was used on a patient in whom the papilloma had twice recurred following uvulopalatopharyngoplasty. Case report and review of the relevant literature. The patient reported in this paper had recurrent squamous papilloma in the nasopharyngeal surface of the soft palate following uvulopalatopharyngoplasty. He also suffered from nasal regurgitation when drinking water. This lesion, which was difficult to access, was successfully treated via a transnasal endoscopic approach using powered instrumentation. This case report highlights a novel approach for the complete removal of a recurrent papilloma in a relatively inaccessible location. Compared with a transoral approach such as uvulopalatopharyngoplasty, the transnasal endoscopic approach using powered instrumentation could provide a safer, faster, easier and less invasive means of treating squamous papilloma in the nasopharyngeal surface of the soft palate, especially for a lesion that recurs following a transoral approach.

  11. Correlation Between Findings of Multislice Helical Computed Tomography (CT), Endoscopic Examinations, Endovascular Procedures, and Surgery in Patients with Symptoms of Acute Gastrointestinal Bleeding

    PubMed Central

    Konecki, Dariusz; Pacho, Ryszard; Rowiński, Olgierd

    2017-01-01

    Summary Background Endoscopic methods (gastroscopy and colonoscopy) are considered fundamental for the diagnosis of gastrointestinal bleeding. In recent years, multidetector computed tomography (MDCT) has also gained importance in diagnosing gastrointestinal bleeding, particularly in hemodynamically unstable patients and in cases with suspected lower gastrointestinal tract bleeding. CT can detect both the source and the cause of active gastrointestinal bleeding, thereby expediting treatment initiation. Material/Methods The study group consisted of 16 patients with clinical symptoms of gastrointestinal bleeding in whom features of active bleeding were observed on CT. In all patients, bleeding was verified by means of other methods such as endoscopic examinations, endovascular procedures, or surgery. Results The bleeding source was identified on CT in all 16 patients. In 14 cases (87.5%), bleeding was confirmed by other methods. Conclusions CT is an efficient, fast, and readily available tool for detecting the location of acute gastrointestinal bleeding. PMID:29662594

  12. Management of the colonic volvulus in 2016.

    PubMed

    Perrot, L; Fohlen, A; Alves, A; Lubrano, J

    2016-06-01

    Colonic volvulus is the third leading cause of colonic obstruction worldwide, occurring at two principal locations: the sigmoid colon and cecum. In Western countries, sigmoid volvulus preferentially affects elderly men whereas cecal volvulus affects younger women. Some risk factors, such as chronic constipation, high-fiber diet, frequent use of laxatives, personal past history of laparotomy and anatomic predispositions, are common to both locations. Clinical symptomatology is non-specific, including a combination of abdominal pain, gaseous distention, and bowel obstruction. Abdominopelvic computerized tomography is currently the gold standard examination, allowing positive diagnosis as well as detection of complications. Specific management depends on the location, patient comorbidities and colonic wall viability, but treatment is an emergency in every case. If clinical or radiological signs of gravity are present, emergency surgery is mandatory, but is associated with high morbidity and mortality rates. For sigmoid volvulus without criteria of gravity, the ideal strategy is an endoscopic detorsion procedure followed, within 2 to 5 days, by surgery that includes a sigmoid colectomy with primary anastomosis. Exclusively endoscopic therapy must be reserved for patients who are at excessive risk for surgical intervention. In cecal volvulus, endoscopy has no role and surgery is the rule. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  13. Superficially located enlarged lymphoid follicles characterise nodular gastritis.

    PubMed

    Okamura, Takuma; Sakai, Yasuhiro; Hoshino, Hitomi; Iwaya, Yugo; Tanaka, Eiji; Kobayashi, Motohiro

    2015-01-01

    Nodular gastritis is a form of chronic Helicobacter pylori gastritis affecting the gastric antrum and characterised endoscopically by the presence of small nodular lesions resembling gooseflesh. It is generally accepted that hyperplasia of lymphoid follicles histologically characterises nodular gastritis; however, quantitative analysis in support of this hypothesis has not been reported. Our goal was to determine whether nodular gastritis is characterised by lymphoid follicle hyperplasia.The number, size, and location of lymphoid follicles in nodular gastritis were determined and those properties compared to samples of atrophic gastritis. The percentages of high endothelial venule (HEV)-like vessels were also evaluated.The number of lymphoid follicles was comparable between nodular and atrophic gastritis; however, follicle size in nodular gastritis was significantly greater than that seen in atrophic gastritis. Moreover, lymphoid follicles in nodular gastritis were positioned more superficially than were those in atrophic gastritis. The percentage of MECA-79 HEV-like vessels was greater in areas with gooseflesh-like lesions in nodular versus atrophic gastritis.Superficially located hyperplastic lymphoid follicles characterise nodular gastritis, and these follicles correspond to gooseflesh-like nodular lesions observed endoscopically. These observations suggest that MECA-79 HEV-like vessels could play at least a partial role in the pathogenesis of nodular gastritis.

  14. Lung cancer. Surgical approaches and incisions.

    PubMed

    Dewey, T M; Mack, M J

    2000-11-01

    With the emphasis of current surgical practice being increasingly focused on reducing the invasiveness of procedures, new techniques and concepts are changing the approach to thoracic surgery. Robotics offers the benefits of scaled motion, tremor filtration, and remote telemanipulation. It may be theoretically possible to introduce the concept of telementoring into thoracic surgery. By coupling two consoles, it would be possible for a senior surgeon to guide a junior surgeon through an endoscopic procedure in which the clinicians were in different locations. The use of telepresence surgery would also enable surgeons to perform or assist in operations taking place in remote locations. Robotics has the potential to increase the applicability of endoscopic surgery to an increasing number of patients with technically complex thoracic problems. Given that this technology is in its infancy, it remains too early in the process to determine if robotics will be a significant "value-added" element of cardiothoracic surgery; however, the possibilities continue to be limited only by imagination and ingenuity.

  15. Review of emerging surgical robotic technology.

    PubMed

    Peters, Brian S; Armijo, Priscila R; Krause, Crystal; Choudhury, Songita A; Oleynikov, Dmitry

    2018-04-01

    The use of laparoscopic and robotic procedures has increased in general surgery. Minimally invasive robotic surgery has made tremendous progress in a relatively short period of time, realizing improvements for both the patient and surgeon. This has led to an increase in the use and development of robotic devices and platforms for general surgery. The purpose of this review is to explore current and emerging surgical robotic technologies in a growing and dynamic environment of research and development. This review explores medical and surgical robotic endoscopic surgery and peripheral technologies currently available or in development. The devices discussed here are specific to general surgery, including laparoscopy, colonoscopy, esophagogastroduodenoscopy, and thoracoscopy. Benefits and limitations of each technology were identified and applicable future directions were described. A number of FDA-approved devices and platforms for robotic surgery were reviewed, including the da Vinci Surgical System, Sensei X Robotic Catheter System, FreeHand 1.2, invendoscopy E200 system, Flex® Robotic System, Senhance, ARES, the Single-Port Instrument Delivery Extended Research (SPIDER), and the NeoGuide Colonoscope. Additionally, platforms were reviewed which have not yet obtained FDA approval including MiroSurge, ViaCath System, SPORT™ Surgical System, SurgiBot, Versius Robotic System, Master and Slave Transluminal Endoscopic Robot, Verb Surgical, Miniature In Vivo Robot, and the Einstein Surgical Robot. The use and demand for robotic medical and surgical platforms is increasing and new technologies are continually being developed. New technologies are increasingly implemented to improve on the capabilities of previously established systems. Future studies are needed to further evaluate the strengths and weaknesses of each robotic surgical device and platform in the operating suite.

  16. Head-mounted display for use in functional endoscopic sinus surgery

    NASA Astrophysics Data System (ADS)

    Wong, Brian J.; Lee, Jon P.; Dugan, F. Markoe; MacArthur, Carol J.

    1995-05-01

    Since the introduction of functional endoscopic sinus surgery (FESS), the procedure has undergone rapid change with evolution keeping pace with technological advances. The advent of low cost charge coupled device 9CCD) cameras revolutionized the practice and instruction of FESS. Video-based FESS has allowed for documentation of the surgical procedure as well as interactive instruction during surgery. Presently, the technical requirements of video-based FESS include the addition of one or more television monitors positioned strategically in the operating room. Thought video monitors have greatly enhanced surgical endoscopy by re- involving nurses and assistants in the actual mechanics of surgery, video monitors require the operating surgeon to be focused on the screen instead of the patient. In this study, we describe the use of a new low-cost liquid crystal display (LCD) based device that functions as a monitor but is mounted on the head on a visor (PT-O1, O1 Products, Westlake Village, CA). This study illustrates the application of these HMD devices to FESS operations. The same surgeon performed the operation in each patient. In one nasal fossa, surgery was performed using conventional video FESS methods. The contralateral side was operated on while wearing the head mounted video display. The device had adequate resolution for the purposes of FESS. No adverse effects were noted intraoperatively. The results on the patients ipsalateral and contralateral sides were similar. The visor did eliminated significant torsion of the surgeon's neck during the operation, while at the same time permitted simultaneous viewing of both the patient and the intranasal surgical field.

  17. Endoscopic laser Doppler flowmetry in the experiment and in the bleeding gastric and duodenal ulcer clinic

    NASA Astrophysics Data System (ADS)

    Kapralov, S. V.; Shapkin, Y. G.; Lychagov, V. V.; Tuchin, V. V.

    2007-05-01

    One of the most complex problems of emergency surgery is the choice of surgical tactics to deal with bleeding peptic ulcer. Endoscopic hemostasis is prescribed to patients with continuing bleedings and prerelapse syndrome. But till nowdays the objective verification of the prerelapse condition had not been worked out. What is more there are no objective criteria to judge the effectiveness of the carried endohemostasis. The aim of the study was to work out a new objective diagnostic method of pre-recurrence syndrome that can be able to make prognosis for possible gastroduodenal ulcer bleeding recurrence more precise. Laser Doppler flowmetry was the method of studies the regional perfusion. The device used in this work was made at the Optics and Biophysics Department of Saratov State University.

  18. Endoscopic closure of persistent gastrocutaneous fistulae, after percutaneous endoscopic gastrostomy (PEG) tube placement, using the over-the-scope-clip system

    PubMed Central

    Changela, Kinesh; Culliford, Andrea; Duddempudi, Sushil; Krishnaiah, Mahesh; Anand, Sury

    2015-01-01

    Objectives: The Over-The-Scope-Clip (OTSC) has had an evolving role in endoscopic closure of gastrointestinal wall defects, in hemostasis of primary or postinterventional bleeding, and approximation of postbariatric surgery defects. Rapid and effective closure of gastrocutaneous (GC) fistulae using this device has been recently described in the literature. The aim of this study was to evaluate the technical feasibility, efficacy and safety of OTSC as an effective tool in the management of persistent GC fistulae secondary to a complication of percutaneous endoscopic gastrostomy (PEG) tube placement. Method: In this multicenter prospective observational study, we describe our experience with OTSC in the closure of persistent GC fistulas secondary to PEG tube placement. Patients with GC fistulas were sequentially enrolled with a mean age of 84 years. Primary treatment outcome was the immediate successful closure of GC fistula and resolution of leak. Secondary outcome was no recurrence of the fistula and leaks on follow up. Results: A total of 10 patients were enrolled over the study period. Mean age was 84.4 ± 8.75 years. The primary treatment outcome was achieved in all the patients undergoing this intervention. Secondary outcome was observed in 9/10 (90%) subjects. No procedural complications were reported. Larger fistulae (>2.5 cm) and those with significant fibrosis were more difficult to close with the OTSC system. The mean follow-up time after OTSC application was 43.7 ± 20.57 days. A limitation of this study was that there was no control group. Conclusions: OTSC application is a safe and effective endoscopic approach for the closure of persistent GC fistulae secondary to a complication of PEG tube placement. PMID:26136836

  19. Endoscopic closure of persistent gastrocutaneous fistulae, after percutaneous endoscopic gastrostomy (PEG) tube placement, using the over-the-scope-clip system.

    PubMed

    Singhal, Shashideep; Changela, Kinesh; Culliford, Andrea; Duddempudi, Sushil; Krishnaiah, Mahesh; Anand, Sury

    2015-07-01

    The Over-The-Scope-Clip (OTSC) has had an evolving role in endoscopic closure of gastrointestinal wall defects, in hemostasis of primary or postinterventional bleeding, and approximation of postbariatric surgery defects. Rapid and effective closure of gastrocutaneous (GC) fistulae using this device has been recently described in the literature. The aim of this study was to evaluate the technical feasibility, efficacy and safety of OTSC as an effective tool in the management of persistent GC fistulae secondary to a complication of percutaneous endoscopic gastrostomy (PEG) tube placement. In this multicenter prospective observational study, we describe our experience with OTSC in the closure of persistent GC fistulas secondary to PEG tube placement. Patients with GC fistulas were sequentially enrolled with a mean age of 84 years. Primary treatment outcome was the immediate successful closure of GC fistula and resolution of leak. Secondary outcome was no recurrence of the fistula and leaks on follow up. A total of 10 patients were enrolled over the study period. Mean age was 84.4 ± 8.75 years. The primary treatment outcome was achieved in all the patients undergoing this intervention. Secondary outcome was observed in 9/10 (90%) subjects. No procedural complications were reported. Larger fistulae (>2.5 cm) and those with significant fibrosis were more difficult to close with the OTSC system. The mean follow-up time after OTSC application was 43.7 ± 20.57 days. A limitation of this study was that there was no control group. OTSC application is a safe and effective endoscopic approach for the closure of persistent GC fistulae secondary to a complication of PEG tube placement.

  20. Validation of adenosine triphosphate to audit manual cleaning of flexible endoscope channels.

    PubMed

    Alfa, Michelle J; Fatima, Iram; Olson, Nancy

    2013-03-01

    Compliance with cleaning of flexible endoscope channels cannot be verified using visual inspection. Adenosine triphosphate (ATP) has been suggested as a possible rapid cleaning monitor for flexible endoscope channels. There have not been published validation studies to specify the level of ATP that indicates inadequate cleaning has been achieved. The objective of this study was to validate the Clean-Trace (3M Inc, St. Paul, MN) ATP water test method for monitoring manual cleaning of flexible endoscopes. This was a simulated use study using a duodenoscope as the test device. Artificial test soil containing 10(6) colony-forming units of Pseudomonas aeruginosa and Enterococcus faecalis was used to perfuse all channels. The flush sample method for the suction-biopsy (L1) or air-water channel (L2) using 40 and 20 mLs sterile reverse osmosis water, respectively, was validated. Residuals of ATP, protein, hemoglobin, and bioburden were quantitated from channel samples taken from uncleaned, partially cleaned, and fully cleaned duodenoscopes. The benchmarks for clean were as follows: <6.4 μg/cm(2) protein, <2.2 μg/cm(2) hemoglobin, and <4-log10 colony-forming units/cm(2) bioburden. The average ATP in clean channel samples was 27.7 RLUs and 154 RLUs for L1 and L2, respectively (<200 RLUs for all channels). The average protein, hemoglobin, and bioburden benchmarks were achieved if <200 RLUs were detected. If the channel sample was >200 RLUs, the residual organic and bioburden levels would exceed the acceptable benchmarks. Our data validated that flexible endoscopes that have complete manual cleaning will have <200 RLUs by the Clean-Trace ATP test. Copyright © 2013 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

  1. A new endoscopic technique for suspension of esophageal prosthesis for refractory caustic esophageal strictures.

    PubMed

    Ancona, E; Guido, E; Cutrone, C; Bocus, P; Rampado, S; Vecchiato, M; Salvador, R; Donach, M; Battaglia, G

    2008-01-01

    There is no clear consensus concerning the best endoscopic treatment of benign refractory esophageal strictures due to caustic ingestion. Different procedures are currently used: frequent multiple dilations, retrievable self-expanding stent, nasogastric intubation and surgery. We describe a new technique to fix a suspended esophageal silicone prosthesis to the neck in benign esophageal strictures; this permits us to avoid the frequent risk of migration of the expandable metallic or plastic stents. Under general anesthesia a rigid esophagoscope was placed in the patient's hypopharynx. Using transillumination from the optical device, the patient's neck was pierced with a needle. A n.0 monofilament surgical wire was pushed into the needle, grasped by a standard foreign body forceps through the esophagoscope and pulled out of the mouth (as in percutaneous endoscopic gastrostomy procedure). After tying the proximal end of the silicone prosthesis with the wire, it was placed through the strictures under endoscopic view. This procedure was successfully utilized in four patients suffering from benign refractory esophageal strictures due to caustic ingestion. The prosthesis and its suspension from the neck were well-tolerated until removal (mean duration 4 months). A postoperative transitory myositis was diagnosed in only one patient. One of the most frequent complications of esophageal prostheses in refractory esophageal strictures due to caustic ingestion is distal migration. Different solutions were proposed. For example the suspension of a wire coming from the nose and then fixed behind the ear. This solution is not considered optimal because of patient complaints and moreover the aesthetic aspect is compromised. The procedure we utilized in four patients utilized the setting of a silicone tube hanging from the neck in a way similar to that of endoscopic pharyngostomy. This solution is a valid alternative both for quality of life and for functional results.

  2. Electrocautery vs non-electrocautery dilation catheters in endoscopic ultrasonography-guided pancreatic fluid collection drainage

    PubMed Central

    Kitamura, Katsuya; Yamamiya, Akira; Ishii, Yu; Nomoto, Tomohiro; Honma, Tadashi; Yoshida, Hitoshi

    2016-01-01

    AIM: To investigate the safety and utility of an electrocautery dilation catheter for endoscopic ultrasonography (EUS)-guided pancreatic fluid collection drainage. METHODS: A single-center, exploratory, retrospective study was conducted between August 2010 and August 2014. This study was approved by the Medical Ethics Committee of our institution. Informed, written consent was obtained from each patient prior to the procedure. The subjects included 28 consecutive patients who underwent EUS-guided transmural drainage (EUS-TD) for symptomatic pancreatic and peripancreatic fluid collections (PFCs) by fine needle aspiration using a 19-gauge needle. These patients were retrospectively divided into two groups based on the use of an electrocautery dilation catheter as a fistula dilation device; 15 patients were treated with an electrocautery dilation catheter (electrocautery group), and 13 patients were treated with a non-electrocautery dilation catheter (non-electrocautery group). We evaluated the technical and clinical successes and the adverse events associated with EUS-TD for the treatment of PFCs between the two groups. RESULTS: There were no significant differences in age, sex, type, location and diameter of PFCs between the groups. Thirteen patients (87%) in the electrocautery group and 10 patients (77%) in the non-electrocautery group presented with infected PFCs. The technical success rates of EUS-TD for the treatment of PFCs were 100% (15/15) and 100% (13/13) for the electrocautery and the non-electrocautery groups, respectively. The clinical success rates of EUS-TD for the treatment of PFCs were 67% (10/15) and 69% (9/13) for the electrocautery and the non-electrocautery groups, respectively (P = 0.794). The procedure time of EUS-TD for the treatment of PFCs in the electrocautery group was significantly shorter than that of the non-electrocautery group (mean ± SD: 30 ± 12 min vs 52 ± 20 min, P < 0.001). Adverse events associated with EUS-TD for the treatment of PFCs occurred in 0 patients and 1 patient for the electrocautery and the non-electrocautery groups, respectively (P = 0.942). CONCLUSION: EUS-TD using an electrocautery dilation catheter as a fistula dilation device for the treatment of symptomatic PFCs appears safe and contributes to a shorter procedure time. PMID:27433292

  3. Management of foreign body ingestion and food bolus impaction in children: a retrospective analysis of 675 cases.

    PubMed

    Antoniou, Dimitris; Christopoulos-Geroulanos, George

    2011-01-01

    Although foreign body ingestion is a common problem in children, there are no clear guidelines regarding the management of ingested foreign bodies. The aim of this study was to evaluate the effectiveness of our protocol in the work-up and management of children with ingested foreign bodies. Between September 2002 and August 2010, a total of 675 children with suspected foreign body ingestion were seen in the emergency department. At initial presentation, the majority of foreign bodies were located in the stomach (n=392, 58.1%) followed by the small intestine (n=221, 32.7%) and esophagus (n=62, 9.2%). Based on our protocol, 84 (12.4%) patients were admitted at initial presentation, and 5 after a 48-hour observation period at home; 61 (9%) required prompt endoscopic removal. Sixty-eight (10.1%) patients returned for endoscopic removal after a four-week observation period, and 3 (0.4%) patients underwent delayed surgery due to complications. The overall success rate of endoscopic retrieval was 96.1%. There were no major complications. The majority of ingested foreign bodies will pass spontaneously and most children can be safely observed at home. Selective endoscopic intervention is the preferable method for the removal of ingested foreign bodies in pediatric patients.

  4. Colonoscopic findings and management of patients with outbreak typhoid fever presenting with lower gastrointestinal bleeding.

    PubMed

    Shaikhani, Mohammad A R; Husein, Hiwa A B; Karbuli, Taha A; Mohamed, Mohamed Abdulrahman

    2013-09-01

    Lower gastrointestinal bleeding (LGIB) along with intestinal perforation is a well-known complication of typhoid fever. Reports of colonoscopic appearance and intervention of typhoid perforation involve only few cases. This series reports the colonoscopic findings and the role of colonoscopic hemostatic interventions in controlling the bleeding ileocolonic lesions. During the typhoid fever outbreak in Sulaymaniyah City in Iraqi Kurdistan Region, we received 52 patients with LGIB manifesting as fresh bleeding per rectum or melena. We performed total colonoscopy with ileal intubation for all cases. The findings were recorded and endoscopic hemostatic intervention with adrenaline-saline injection and argon plasma coagulation was applied to actively bleeding lesion. These patients were young, 11-30 years of age, with female preponderance. Blood culture was positive in 50 %. Colonoscopic findings were mostly located in the ileocecal region, although other areas of the colon were involved in many cases. Twenty-four percent of the cases required endoscopic hemostatic intervention by adrenaline injection with argon plasma coagulation which was effective in all patients except one who died in spite of surgical intervention in addition of endoscopic hemostasis. Dual endoscopic hemostatic intervention can be a safe and effective management option for patients with LGIB due to typhoid fever.

  5. Miniaturized camera system for an endoscopic capsule for examination of the colonic mucosa

    NASA Astrophysics Data System (ADS)

    Wippermann, Frank; Müller, Martin; Wäny, Martin; Voltz, Stephan

    2014-09-01

    Todaýs standard procedure for the examination of the colon uses a digital endoscope located at the tip of a tube encasing wires for camera read out, fibers for illumination, and mechanical structures for steering and navigation. On the other hand, there are swallowable capsules incorporating a miniaturized camera which are more cost effective, disposable, and less unpleasant for the patient during examination but cannot be navigated along the path through the colon. We report on the development of a miniaturized endoscopic camera as part of a completely wireless capsule which can be safely and accurately navigated and controlled from the outside using an electromagnet. The endoscope is based on a global shutter CMOS-imager with 640x640 pixels and a pixel size of 3.6μm featuring through silicon vias. Hence, the required electronic connectivity is done at its back side using a ball grid array enabling smallest lateral dimensions. The layout of the f/5-objective with 100° diagonal field of view aims for low production cost and employs polymeric lenses produced by injection molding. Due to the need of at least one-time autoclaving, high temperature resistant polymers were selected. Optical and mechanical design considerations are given along with experimental data obtained from realized demonstrators.

  6. Reality named endoscopic ultrasound biliary drainage

    PubMed Central

    Guedes, Hugo Gonçalo; Lopes, Roberto Iglesias; de Oliveira, Joel Fernandez; Artifon, Everson Luiz de Almeida

    2015-01-01

    Endoscopic ultrasound (EUS) is used for diagnosis and evaluation of many diseases of the gastrointestinal (GI) tract. In the past, it was used to guide a cholangiography, but nowadays it emerges as a powerful therapeutic tool in biliary drainage. The aims of this review are: outline the rationale for endoscopic ultrasound-guided biliary drainage (EGBD); detail the procedural technique; evaluate the clinical outcomes and limitations of the method; and provide recommendations for the practicing clinician. In cases of failed endoscopic retrograde cholangiopancreatography (ERCP), patients are usually referred for either percutaneous transhepatic biliary drainage (PTBD) or surgical bypass. Both these procedures have high rates of undesirable complications. EGBD is an attractive alternative to PTBD or surgery when ERCP fails. EGBD can be performed at two locations: transhepatic or extrahepatic, and the stent can be inserted in an antegrade or retrograde fashion. The drainage route can be transluminal, duodenal or transpapillary, which, again, can be antegrade or retrograde [rendezvous (EUS-RV)]. Complications of all techniques combined include pneumoperitoneum, bleeding, bile leak/peritonitis and cholangitis. We recommend EGBD when bile duct access is not possible because of failed cannulation, altered upper GI tract anatomy, gastric outlet obstruction, a distorted ampulla or a periampullary diverticulum, as a minimally invasive alternative to surgery or radiology. PMID:26504507

  7. Endoscopic ultrasound-guided fine-needle aspiration needles: which one and in what situation?

    PubMed

    Karadsheh, Zeid; Al-Haddad, Mohammad

    2014-01-01

    Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) is increasingly used as a diagnostic and therapeutic tool for pancreatic and other gastrointestinal disorders. Several factors affect the outcome of EUS-FNA, one of which is needle size. The decision to use a specific needle depends on factors including location, consistency, and type of the lesion; presence of onsite cytopathologist; and need for additional tissue procurement for histology. This review provides a balanced perspective on the use of different needle sizes available, highlighting the differences among them and potential niche applications of each to maximize diagnostic yield of EUS-FNA. Copyright © 2014 Elsevier Inc. All rights reserved.

  8. [Sachse internal urethrotomy: endoscopic treatment of urethral strictures].

    PubMed

    Pfalzgraf, D; Häcker, A

    2013-05-01

    The most commonly used treatment modality for urethral strictures is the direct visual internal urethrotomy (DVUI) method according to Sachse. It is an effective short-term treatment, but the long-term success rate is low. A number of factors influence the outcome of DVUI including stricture location, spongiofibrosis and previous endoscopic stricture treatment. Multiple urethrotomy has a negative impact on the success rate of subsequent urethroplasty. A thorough preoperative diagnostic work-up including combined retrograde urethrogram/voiding cystourethrogram (RUG/VCUG) and urethrocystoscopy is, therefore, mandatory to allow for patient counselling regarding the risk of stricture recurrence and other treatment options. After a failed primary DVUI, subsequent urethrotomy cannot be expected to be curative.

  9. Topical Drug Delivery for Chronic Rhinosinusitis

    PubMed Central

    Liang, Jonathan; Lane, Andrew P.

    2013-01-01

    Chronic rhinosinusitis is a multifactorial disorder that may be heterogeneous in presentation and clinical course. While the introduction of endoscopic sinus surgery revolutionized surgical management and has led to significantly improved patient outcomes, medical therapy remains the foundation of long-term care of chronic rhinosinusitis, particularly in surgically recalcitrant cases. A variety of devices and pharmaceutical agents have been developed to apply topical medical therapy to the sinuses, taking advantage of the access provided by endoscopic surgery. The goal of topical therapy is to address the inflammation, infection, and mucociliary dysfunction that underlies the disease. Major factors that impact success include the patient’s sinus anatomy and the dynamics of the delivery device. Despite a growing number of topical treatment options, the evidence-based literature to support their use is limited. In this article, we comprehensively review current delivery methods and the available topical agents. We also discuss biotechnological advances that promise enhanced delivery in the future, and evolving pharmacotherapeutical compounds that may be added to rhinologist’s armamentarium. A complete understand of topical drug delivery is increasingly essential to the management of chronic rhinosinusitis when traditional forms of medical therapy and surgery have failed. PMID:23525506

  10. Natural orifice translumenal endoscopic surgery: Progress in humans since white paper

    PubMed Central

    Santos, Byron F; Hungness, Eric S

    2011-01-01

    Since the first description of the concept of natural orifice translumenal endoscopic surgery (NOTES), a substantial number of clinical NOTES reports have appeared in the literature. This editorial reviews the available human data addressing research questions originally proposed by the white paper, including determining the optimal method of access for NOTES, developing safe methods of lumenal closure, suturing and anastomotic devices, advanced multitasking platforms, addressing the risk of infection, managing complications, addressing challenges with visualization, and training for NOTES procedures. An analysis of the literature reveals that so far transvaginal access and closure appear to be the most feasible techniques for NOTES, with a limited, but growing transgastric, transrectal, and transesophageal NOTES experience in humans. The theoretically increased risk of infection as a result of NOTES procedures has not been substantiated in transvaginal and transgastric procedures so far. Development of suturing and anastomotic devices and advanced platforms for NOTES has progressed slowly, with limited clinical data on their use so far. Data on the optimal management and incidence of intraoperative complications remain sparse, although possible factors contributing to complications are discussed. Finally, this editorial discusses the likely direction of future NOTES development and its possible role in clinical practice. PMID:21483624

  11. Dual-modality smartphone endoscope for cervical pre-cancer detection (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Hong, Xiangqian; Yu, Bing

    2017-02-01

    Early detection is the key to the prevention of cervical cancer. There is an urgent need for a portable, affordable, and easy-to-use device for cervical pre-cancer detection, especially in low-resource settings. We have developed a dual-modality fiber-optic endoscope system (SmartME) that integrates high-resolution fluorescence imaging (FLI) and quantitative diffuse reflectance spectroscopy (DRS) onto a smartphone platform. The SmartME consists of a smartphone, a miniature fiber-optic endoscope, a phone attachment containing imaging optics, and a smartphone application (app). FLI is obtained by painting the tissue with a contrast agent (e.g., proflavine), illuminating the tissue and collecting its fluorescence images through an imaging bundle that is coupled to the phone camera. DRS is achieved by using a white LED, attaching additional source and detection fibers to the imaging bundle, and converting the phone camera into a spectrometer. The app collects images/spectra and transmits them to a remote server for analysis to extract the tissue parameters, including nuclear-to-cytoplasm ratio (calculated from FLI), concentrations of oxyhemoglobin (HbO2) and deoxyhemoglobin (Hb) as well as scattering (measured by DRS). These parameters can be used to detect cervical dysplasia. Our preliminary studies have demonstrated that the SmartME can clearly visualize the nuclei in living cells and in vivo biological samples, with a high spatial resolution of 3.1μm. The device can also measure tissue absorption and scattering properties with comparable accuracy to those of a benchtop DRS system. The SmartME has great potential to provide a compact, affordable, and `smart' solution for early detection of neoplastic changes in cervix.

  12. Surgical management of juvenile nasopharyngeal angiofibroma: analysis of 162 cases from 1995 to 2012.

    PubMed

    Huang, Yang; Liu, Zhuofu; Wang, Jingjing; Sun, Xicai; Yang, Lei; Wang, Dehui

    2014-08-01

    The purpose of this study was to report on a series of 162 patients presenting with juvenile nasopharyngeal angiofibroma in a single academic hospital during the past 17 years, in an effort to compare outcomes between open and transnasal endoscopic approach, and to define an ideal treatment strategy. Patients who received either open or endoscopic surgery with a minimum follow-up of 6 months were selected. Local control and complications were compared between groups. Retrospectively, clinical data, surgical reports, pre- and postoperative images, and follow-up information were reviewed and analyzed. All patients were male subjects from 8 to 41 years old. Ninety-six patients were treated by transpalatal or transmaxillary approach, and the remaining 66 patients were treated using transnasal endoscopic approach with/without labiogingival incision. When compared to the open surgery group, the endoscopic surgery group showed a lower median intraoperative blood loss (800 vs. 1100 mL, P = .017) and a lower number of postoperative complications (one vs. 10). In addition, recurrence statistically correlated with Radkowski's classification and patient age. Transnasal endoscopic approach can be successfully used for Radkowski's stages I-IIb tumors and selective IIc-IIIb lesions, allowing for less blood loss, fewer postoperative complications, and a lower percentage of recurrence in comparison to open surgery. The management of recurrent tumor is complex, should be individually tailored, and should take into account tumor location, patient age, complications of treatment, and the possibility of spontaneous involution, to better define treatment strategy. © 2014 The American Laryngological, Rhinological and Otological Society, Inc.

  13. [Endonasal micro-endoscopic resection of sinonasal inverted papilloma].

    PubMed

    Minovi, A; Kollert, M; Draf, W; Bockmühl, U

    2006-06-01

    The goal of this study was to assess the potentials and limitations of endonasal micro-endoscopic surgery in the treatment of sinonasal inverted papilloma (IP) and to demonstrate long-term results. From 1989 to 2005, 64 patients underwent resection of IP via an endonasal approach using either the endoscope or microscope. Charts were reviewed retrospectively for presenting symptoms, radiological and intraoperative data. All patients were followed by endoscopic and MRI control during a period of up to 174 months, median follow-up was 78 months. Our study group consisted of 26 male and 38 female patients with an average age of 54.3 years. The majority of the patients (67 %) complained of unilateral nasal obstruction. 52 patients (81 %) were referred for primary surgery. In 12 cases (19 %) recurrent tumors were operated. According to the Krouse classification for IP the tumors were staged as T1 = 11 (17 %) cases, T2 = 37 (58 %) and T3 = 14 (22 %). In two patients a squamous cell carcinoma was associated with an IP ( = T4 stage). Most tumors were localized within the nasal cavity (72 %) or the anterior ethmoid (62 %). In 10 patients an infiltration of the bony skull base was present. During the follow-up period 6 patients developed recurrencies corresponding to an overall recurrence rate of 9.4 %. The advances in endonasal micro-endoscopic surgery allow both safe and effective removal of IP with low morbidity, and therefore it should be the approach of the first choice. The osteoplastic approach combined with endonasal surgery is suitable in far lateral located IP. Close follow-up is mandatory to ensure the surgical success.

  14. Spontaneous CSF-leaks and meningoencephaloceles in sphenoid sinus by persisting Sternberg's canal.

    PubMed

    Tomazic, Peter Valentin; Stammberger, Heinz

    2009-12-01

    Cerebrospinal fluid (CSF) leaks and meningoencephaloceles of the lateral recess of sphenoid sinuses are rare findings. A congenital bony defect in the lateral wall of sphenoid sinus called Sternberg's canal could be the origin of these lesions. Their endoscopic transnasal management is challenging though less traumatic than transcranial approaches. The aim of this study was to define Sternberg's canal as a potential source for these rare lesions and to describe their endoscopic endonasal management. In a retrospective analysis clinical charts of 27 patients with CSF-leaks and / or meningoencephaloceles operated between March 2002 and October 2008 at the University ENT-hospital Graz have been reviewed. All patients were treated by an endoscopic endonasal approach. Five patients (4 female / 1 male) were identified with spontaneous CSF-leaks from sphenoid sinus and meningoencephaloceles. In all five cases, Sternberg's canal was the site of leakage, with the bony and dural defects always located laterally between the maxillary and Vidian nerves. Mean age was 51.2 years and mean body mass index (BMI) was 31.9 kg/m2. All patients were operated using a multilayer closure technique. Two patients had recurrences after 12 days and 7 months, respectively, managed by endoscopic revision surgery resulting in a 100% closure rate after one revision (mean follow-up: 6.5 months). Persisting Sternberg's canal can be the source of spontaneous CSF-leaks and meningoencephaloceles in the lateral recess of sphenoid sinus especially when associated with extensive pneumatisation. Endoscopic management is technically challenging, nevertheless its advantages are a good view of the surgical field while being less traumatic than transcranial approaches.

  15. Feasibility of telementoring between Baltimore (USA) and Rome (Italy): the first five cases.

    PubMed

    Micali, S; Virgili, G; Vannozzi, E; Grassi, N; Jarrett, T W; Bauer, J J; Vespasiani, G; Kavoussi, L R

    2000-08-01

    Telemedicine is the use of telecommunication technology to deliver healthcare. Telementoring has been developed to allow a surgeon at a remote site to offer guidance and assistance to a less-experienced surgeon. We report on our experience during laparoscopic urologic procedures with mentoring between Rome, Italy, and Baltimore, USA. Over a period of 3 months, two laparoscopic left spermatic vein ligations, one retroperitoneal renal biopsy, one laparoscopic nephrectomy, and one percutaneous access to the kidney were telementored. Transperitoneal laparoscopic cases were performed with the use of AESOP, a robotic for remote manipulation of the endoscopic camera. A second robot, PAKY, was used to perform radiologically guided needle orientation and insertion for percutaneous renal access. In addition to controlling the robotic devices, the system provided real-time video display for either the laparoscope or an externally mounted camera located in the operating room, full duplex audio, telestration over live video, and access to electrocautery for tissue cutting or hemostasis. All procedures were accomplished with an uneventful postoperative course. One technical failure occurred because the robotic device was not properly positioned on the operating table. The round-trip delay of image transmission was less than 1 second. International telementoring is a feasible technique that can enhance surgeon education and decrease the likelihood of complications attributable to inexperience with new operative techniques.

  16. Interest of submucosal dissection knife for endoscopic treatment of Zenker's diverticulum.

    PubMed

    Laquière, A; Grandval, P; Arpurt, J P; Boulant, J; Belon, S; Aboukheir, S; Laugier, R; Penaranda, G; Curel, L; Boustière, C

    2015-09-01

    Dual-Knife(®) (Olympus) and Hydride-Knife(®) are new needle knives frequently used for submucosal dissection because of their safety and precision. In this study we aimed to evaluate the efficacy and safety of such devices in the diverticulopexy by flexible endoscopy. From February 2009 to March 2013, 42 patients (25 men), mean age 74.5, with symptomatic Zenker's diverticulum, were included in a non-randomized prospective multicenter study. The symptoms described by all patients include dysphagia, regurgitation and/or swallowing disorders. The diverticulopexy was performed with the Dual-Knife(®) or Hydrid-Knife(®), after septum exposure with the diverticuloscope, and terminated with distal tip clips positioning. All complications were noted. Patients' symptoms were regularly assessed during follow-up visits or telephone interviews. The first endoscopy treatment was successful for all patients. Thirty-seven patients (88%) had symptoms improvement after the first treatment. The recurrence rate was 14% (6 patients); a second endoscopic treatment was required 12 months on average after the first treatment, with 100% efficiency. Mid-term (16 months) efficiency was 91.67% after 1 to 3 endoscopic treatments. A total of 55 procedures were performed without perforation or significant bleeding and 3 patients underwent surgery. In multivariate analysis, the diverticulum size and the type of dissection knife were not risks factors for recurrence. Endoscopic diverticuloscope-assisted diverticulotomy with submucosal dissection knives is a safe and effective alternative treatment for patients with a symptomatic Zenker's diverticulum measuring between 2 and 10 cm.

  17. Ultra-minimally invasive local immune cell therapy and regenerative therapy by multi-piercing surgery for abdominal solid tumor: therapeutic simulation by natural orifice translumenal endoscopic surgery-assisted needlescopic surgery using 3-mm diameter robots.

    PubMed

    Ohdaira, Takeshi; Tsutsumi, Norifumi; Xu, Hao; Mori, Megumu; Uemura, Munenori; Ieiri, Satoshi; Hashizume, Makoto

    2011-07-01

    We have invented multi-piercing surgery (MPS) which could potentially solve the triangular formation loss and device clashing which occur in single-port surgery (SPS), as well as restricted visual field, organ damage by needle-type instruments, and impaired removal of a resected organ from the body which occur in needlescopic surgery (NS). MPS is natural orifice translumenal endoscopic surgery (NOTES)-assisted NS. We used 3-mm diameter robots as needle-type instruments for MPS to examine the possibility of local immune cell therapy and regenerative therapy using stem cells for pancreatic cancer. In MPS using two robots, the therapeutic cell suspension was injected into a target region of pancreas in two pigs. Both retention of a capsule of liquid cell suspension and invasive level were evaluated. Triangular formation could be ensured. The use of small-diameter robots allowed (1) the surgical separation of the pancreas and the retroperitoneum, and (2) the formation of the capsule containing the immune cell and stem cell suspension. The endoscope for NOTES provided a clear visual field and also assisted the removal of a resected organ from the body. The visual field of the endoscope could be oriented well by using an electromagnetic navigation system. MPS using small-diameter robots could potentially solve the issues inherent in SPS and NS and could allow minimally invasive local immune cell and stem cell therapy.

  18. WEO position statement on hygiene in digestive endoscopy: Focus on endoscopy units in Asia and the Middle East.

    PubMed

    Murdani, Abdullah; Kumar, Ajay; Chiu, Han-Mo; Goh, Khean-Lee; Jang, Byung Ik; Khor, Christopher J L; Lau, James; Mostafa, Ibrahim; Ramchandani, Mohan; Ratanalert, Siriporn; Tajiri, Hisao; Yuen, Minghwa; Zhang, Shu Tian; Duforest-Rey, Dianelle; Rey, Jean-Francois

    2017-01-01

    The aim of this position statement is to reinforce the key points of hygiene in digestive endoscopy. The present article details the minimum hygiene requirements for reprocessing of endoscopes and endoscopic devices, regardless of the reprocessing method (automated washer-disinfector or manual cleaning) and the endoscopy setting (endoscopy suite, operating room, elective or emergency procedures). These minimum requirements are mandatory for patient safety. Both advanced diagnostic and therapeutic endoscopies should be carried out in an environment that is safe for patients and staff. Particular attention is given to contaminants. Procedural errors in decontamination, defective equipment, and failure to follow disinfection guidelines are major factors contributing to transmission of infection during endoscopy. Other important risk factors include inadequate cleaning, use of older endoscopes with surface and working channel irregularities, and contamination of water bottles or irrigating solutions. Infections by multidrug-resistant organisms have become an increasing problem in health-care systems worldwide. Since 2010, outbreaks of multidrug-resistant bacteria associated with endoscopic retrograde cholangiopancreatography have been reported from the USA, France, Germany, and The Netherlands. In many endoscopy units in Asia and the Middle East, reprocessing procedures have lagged behind those of Western countries for cultural reasons or lack of financial resources. This inconsistency in standards is now being addressed, and the World Endoscopy Organization has prepared this position statement to highlight key points for quality assurance in any endoscopy unit in any country. © 2016 Japan Gastroenterological Endoscopy Society.

  19. Novel computer-based endoscopic camera

    NASA Astrophysics Data System (ADS)

    Rabinovitz, R.; Hai, N.; Abraham, Martin D.; Adler, Doron; Nissani, M.; Fridental, Ron; Vitsnudel, Ilia

    1995-05-01

    We have introduced a computer-based endoscopic camera which includes (a) unique real-time digital image processing to optimize image visualization by reducing over exposed glared areas and brightening dark areas, and by accentuating sharpness and fine structures, and (b) patient data documentation and management. The image processing is based on i Sight's iSP1000TM digital video processor chip and Adaptive SensitivityTM patented scheme for capturing and displaying images with wide dynamic range of light, taking into account local neighborhood image conditions and global image statistics. It provides the medical user with the ability to view images under difficult lighting conditions, without losing details `in the dark' or in completely saturated areas. The patient data documentation and management allows storage of images (approximately 1 MB per image for a full 24 bit color image) to any storage device installed into the camera, or to an external host media via network. The patient data which is included with every image described essential information on the patient and procedure. The operator can assign custom data descriptors, and can search for the stored image/data by typing any image descriptor. The camera optics has extended zoom range of f equals 20 - 45 mm allowing control of the diameter of the field which is displayed on the monitor such that the complete field of view of the endoscope can be displayed on all the area of the screen. All these features provide versatile endoscopic camera with excellent image quality and documentation capabilities.

  20. Ligation-assisted endoscopic submucosal resection with apical mucosal incision to treat gastric subepithelial tumors originating from the muscularis propria.

    PubMed

    Zhang, Dingguo; Lin, Qiuling; Shi, Ruiyue; Wang, Lisheng; Yao, Jun; Tian, Yanhui

    2018-06-18

     This study aimed to evaluate the clinical efficacy, safety, and feasibility of performing endoscopic submucosal resection with a ligation device (ESMR-L) after apical mucosal incision (AMI) for the treatment of gastric subepithelial tumors originating from the muscularis propria (SET-MPs).  14 patients with gastric SET-MPs were treated by ESMR-L with AMI between December 2016 and May 2017. The complete resection rate, operation duration, and postoperative complications were collected. All patients were followed for 2 - 6 months.  The complete resection rate was 100 %, the mean tumor size was 10.71 ± 3.45 mm (7 - 18 mm), and the median operative time was 18.5 minutes. Perforation occurred in four patients, with all lesions being completely repaired endoscopically. No delayed bleeding or peritoneal signs were observed. No residual lesions or recurrence were found during the follow-up period.  AMI with ESMR-L appears to be an efficient and simple method for the histological diagnosis of gastric SET-MPs, but it carries a high perforation rate and cannot guarantee cure. © Georg Thieme Verlag KG Stuttgart · New York.

  1. Comparison of endoscopic-assisted and temporary keratoprosthesis-assisted vitrectomy in combat ocular trauma: experience at a tertiary eye center in Turkey.

    PubMed

    Ayyildiz, Onder; Hakan Durukan, Ali

    2018-01-01

    Objective This study was performed to compare the functional and anatomical results of endoscopic-assisted and temporary keratoprosthesis (TKP)-assisted vitrectomy in patients with combat ocular trauma (COT). Methods The medical records of 14 severely injured eyes of 12 patients who underwent endoscopy or TKP implantation in combination with vitreoretinal surgery from 2007 to 2015 were retrospectively evaluated. The patients' ocular history and functional and anatomic anterior and posterior segment results were analyzed. Results Eight eyes (57%) underwent TKP-assisted vitrectomy and six eyes (43%) underwent endoscopic vitrectomy. The most common cause of COT was detonation of improvised explosive devices (72%), and the most common type of injury was an intraocular foreign body (50%). The median time from trauma to surgery and the median surgical time were significantly shorter in the endoscopy than TKP group. The postoperative functional and anatomical results were not significantly different between the two groups. Conclusions TKP-assisted vitrectomy should be performed in eyes requiring extensive bimanual surgery. In such cases, a corneal graft must be preserved for the TKP at the end of the surgery. Endoscopy shortens the surgical time and can reduce the complication rate.

  2. Contrast limiting factors of optical fiber bundles for flexible endoscopy

    NASA Astrophysics Data System (ADS)

    Ortega-Quijano, N.; Arce-Diego, J. L.; Fanjul-Vélez, F.

    2008-11-01

    Medical endoscopy constitutes a basic device for the development of minimally invasive procedures for a wide range of medical applications, involving diagnosis, treatment and surgery, as well as biopsy sampling. Its minimally invasive nature results in no surgery, or only small incisions, which involves a minimal hospitalization time. The medical relevance of endoscopes relies on the fact that they are one of the most effective means of early stages of cancer diagnosis, with the subsequent improvement in the patient's quality of life. Flexible endoscopy by means of coherent optical fiber bundles shows both flexibility and a high active area. However, the parallel arrangement of the fibers within the bundle produces interference phenomena between them, which results in optical crosstalk. As a consequence, there is a power exchange between contiguous fibers, producing a worsening in the contrast of the image. In this work, this quality limiting factor is deeply studied. We quantitatively analyze crosstalk, performing several studies that show the limitations imposed to the endoscopic system. Finally, we propose some solutions by an analytical method to accurately determine the appropriate optical fibers for each particular design. The method is also applied to endoscopic OCT.

  3. Plastic Biliary Stent Migration During Multiple Stents Placement and Successful Endoscopic Removal Using Intra-Stent Balloon Inflation Technique: A Case Report and Literature Review.

    PubMed

    Calcara, Calcedonio; Broglia, Laura; Comi, Giovanni; Balzarini, Marco

    2016-02-05

    Late migration of a plastic biliary stent after endoscopic placement is a well known complication, but there is little information regarding migration of a plastic stent during multiple stents placement. A white man was hospitalized for severe jaundice due to neoplastic hilar stenosis. Surgical eligibility appeared unclear on admission and endoscopy was carried out, but the first stent migrated proximally at the time of second stent insertion. After failed attempts with various devices, the migrated stent was removed successfully through cannulation with a dilation balloon. The migration of a plastic biliary stent during multiple stents placement is a possible complication. In this context, extraction can be very complicated. In our patient, cannulation of a stent with a dilation balloon was the only effective method.

  4. Using typical endoscopic features to diagnose esophageal squamous papilloma.

    PubMed

    Wong, Ming-Wun; Bair, Ming-Joug; Shih, Shou-Chuan; Chu, Cheng-Hsin; Wang, Horng-Yuan; Wang, Tsang-En; Chang, Chen-Wang; Chen, Ming-Jen

    2016-02-21

    To better understand some of the superficial tiny lesions that are recognized as squamous papilloma of the esophagus (SPE) and receive a different pathological diagnosis. All consecutive patients with esophageal polypoid lesions detected by routine endoscopy at our Endoscopy Centre between October 2009 and June 2014 were retrospectively analysed. We enrolled patients with SPE or other superficial lesions to investigate four key endoscopic appearances (whitish color, exophytic growth, wart-like shape, and surface vessels) and used narrow band imaging (NBI) to distinguish their differences. These series endoscopic images of each patient were retrospectively reviewed by three experienced endoscopists with no prior access to the images. All lesion specimens obtained by forceps biopsy were fixed in formalin and processed for pathological examination. The following data were collected from patient medical records: gender, age, indications for esophagogastroduodenoscopy, and endoscopic characteristics including lesion location, number, color, size, surface morphology, surrounding mucosa, and surface vessels under NBI. Clinicopathological features were also compared. During the study period, 41 esophageal polypoid lesions from 5698 endoscopic examinations were identified retrospectively. These included 24 patients with pathologically confirmed SPE, 11 patients with squamous hyperplasia, three patients with glycogenic acanthosis, two patients with ectopic sebaceous glands, and one patient with a xanthoma. In the χ (2) test, exophytic growth (P = 0.003), a wart-like shape (P < 0.001), and crossing surface vessels under NBI (P = 0.001) were more frequently observed in SPE than in other lesion types. By contrast, there was no significant difference regarding the appearance of a whitish color between SPE and other lesion types (P = 0.872). The most sensitive characteristic was wart-like projections (81.3%) and the most specific was exophytic growth (87.5%). Promising positive predictive values of 84.2%, 80.8%, and 82.6% were noted for exophytic growth, wart-like projections, and surface vessel crossing on NBI, respectively. The use of three key typical endoscopic appearances--exophytic growth, a wart-like shape, and vessel crossing on the lesion surface under NBI--has a promising positive predictive value of 88.2%. This diagnostic triad is useful for the endoscopic diagnosis of SPE.

  5. Using typical endoscopic features to diagnose esophageal squamous papilloma

    PubMed Central

    Wong, Ming-Wun; Bair, Ming-Joug; Shih, Shou-Chuan; Chu, Cheng-Hsin; Wang, Horng-Yuan; Wang, Tsang-En; Chang, Chen-Wang; Chen, Ming-Jen

    2016-01-01

    AIM: To better understand some of the superficial tiny lesions that are recognized as squamous papilloma of the esophagus (SPE) and receive a different pathological diagnosis. METHODS: All consecutive patients with esophageal polypoid lesions detected by routine endoscopy at our Endoscopy Centre between October 2009 and June 2014 were retrospectively analysed. We enrolled patients with SPE or other superficial lesions to investigate four key endoscopic appearances (whitish color, exophytic growth, wart-like shape, and surface vessels) and used narrow band imaging (NBI) to distinguish their differences. These series endoscopic images of each patient were retrospectively reviewed by three experienced endoscopists with no prior access to the images. All lesion specimens obtained by forceps biopsy were fixed in formalin and processed for pathological examination. The following data were collected from patient medical records: gender, age, indications for esophagogastroduodenoscopy, and endoscopic characteristics including lesion location, number, color, size, surface morphology, surrounding mucosa, and surface vessels under NBI. Clinicopathological features were also compared. RESULTS: During the study period, 41 esophageal polypoid lesions from 5698 endoscopic examinations were identified retrospectively. These included 24 patients with pathologically confirmed SPE, 11 patients with squamous hyperplasia, three patients with glycogenic acanthosis, two patients with ectopic sebaceous glands, and one patient with a xanthoma. In the χ2 test, exophytic growth (P = 0.003), a wart-like shape (P < 0.001), and crossing surface vessels under NBI (P = 0.001) were more frequently observed in SPE than in other lesion types. By contrast, there was no significant difference regarding the appearance of a whitish color between SPE and other lesion types (P = 0.872). The most sensitive characteristic was wart-like projections (81.3%) and the most specific was exophytic growth (87.5%). Promising positive predictive values of 84.2%, 80.8%, and 82.6% were noted for exophytic growth, wart-like projections, and surface vessel crossing on NBI, respectively. CONCLUSION: The use of three key typical endoscopic appearances - exophytic growth, a wart-like shape, and vessel crossing on the lesion surface under NBI - has a promising positive predictive value of 88.2%. This diagnostic triad is useful for the endoscopic diagnosis of SPE. PMID:26900297

  6. Design of embedded endoscopic ultrasonic imaging system

    NASA Astrophysics Data System (ADS)

    Li, Ming; Zhou, Hao; Wen, Shijie; Chen, Xiodong; Yu, Daoyin

    2008-12-01

    Endoscopic ultrasonic imaging system is an important component in the endoscopic ultrasonography system (EUS). Through the ultrasonic probe, the characteristics of the fault histology features of digestive organs is detected by EUS, and then received by the reception circuit which making up of amplifying, gain compensation, filtering and A/D converter circuit, in the form of ultrasonic echo. Endoscopic ultrasonic imaging system is the back-end processing system of the EUS, with the function of receiving digital ultrasonic echo modulated by the digestive tract wall from the reception circuit, acquiring and showing the fault histology features in the form of image and characteristic data after digital signal processing, such as demodulation, etc. Traditional endoscopic ultrasonic imaging systems are mainly based on image acquisition and processing chips, which connecting to personal computer with USB2.0 circuit, with the faults of expensive, complicated structure, poor portability, and difficult to popularize. To against the shortcomings above, this paper presents the methods of digital signal acquisition and processing specially based on embedded technology with the core hardware structure of ARM and FPGA for substituting the traditional design with USB2.0 and personal computer. With built-in FIFO and dual-buffer, FPGA implement the ping-pong operation of data storage, simultaneously transferring the image data into ARM through the EBI bus by DMA function, which is controlled by ARM to carry out the purpose of high-speed transmission. The ARM system is being chosen to implement the responsibility of image display every time DMA transmission over and actualizing system control with the drivers and applications running on the embedded operating system Windows CE, which could provide a stable, safe and reliable running platform for the embedded device software. Profiting from the excellent graphical user interface (GUI) and good performance of Windows CE, we can not only clearly show 511×511 pixels ultrasonic echo images through application program, but also provide a simple and friendly operating interface with mouse and touch screen which is more convenient than the traditional endoscopic ultrasonic imaging system. Including core and peripheral circuits of FPGA and ARM, power network circuit and LCD display circuit, we designed the whole embedded system, achieving the desired purpose by implementing ultrasonic image display properly after the experimental verification, solving the problem of hugeness and complexity of the traditional endoscopic ultrasonic imaging system.

  7. 21 CFR 864.5260 - Automated cell-locating device.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Automated cell-locating device. 864.5260 Section... § 864.5260 Automated cell-locating device. (a) Identification. An automated cell-locating device is a device used to locate blood cells on a peripheral blood smear, allowing the operator to identify and...

  8. 21 CFR 864.5260 - Automated cell-locating device.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Automated cell-locating device. 864.5260 Section... § 864.5260 Automated cell-locating device. (a) Identification. An automated cell-locating device is a device used to locate blood cells on a peripheral blood smear, allowing the operator to identify and...

  9. 21 CFR 864.5260 - Automated cell-locating device.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Automated cell-locating device. 864.5260 Section... § 864.5260 Automated cell-locating device. (a) Identification. An automated cell-locating device is a device used to locate blood cells on a peripheral blood smear, allowing the operator to identify and...

  10. 21 CFR 864.5260 - Automated cell-locating device.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Automated cell-locating device. 864.5260 Section... § 864.5260 Automated cell-locating device. (a) Identification. An automated cell-locating device is a device used to locate blood cells on a peripheral blood smear, allowing the operator to identify and...

  11. 21 CFR 864.5260 - Automated cell-locating device.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Automated cell-locating device. 864.5260 Section... § 864.5260 Automated cell-locating device. (a) Identification. An automated cell-locating device is a device used to locate blood cells on a peripheral blood smear, allowing the operator to identify and...

  12. An automated spring-loaded needle for endoscopic ultrasound-guided abdominal paracentesis in cancer patients

    PubMed Central

    Suzuki, Rei; Irisawa, Atsushi; Bhutani, Manoop S; Hikichi, Takuto; Takagi, Tadayuki; Shibukawa, Goro; Sato, Ai; Sato, Masaki; Ikeda, Tsunehiko; Watanabe, Ko; Nakamura, Jun; Annangi, Srinadh; Tasaki, Kazuhiro; Obara, Katsutoshi; Ohira, Hiromasa

    2014-01-01

    AIM: To evaluate the feasibility of using an automated spring-loaded needle device for endoscopic ultrasound (EUS)-guided abdominal paracentesis (EUS-P) to see if this would make it easier to puncture the mobile and lax gastric wall for EUS-P. METHODS: The EUS database and electronic medical records at Fukushima Medical University Hospital were searched from January 2001 to April 2011. Patients with a history of cancer and who underwent EUS-P using an automated spring-loaded needle device with a 22-gauge puncture needle were included. The needle was passed through the instrument channel and advanced through the gastrointestinal wall under EUS guidance into the echo-free space in the abdominal cavity and ascitic fluid was collected. The confirmed diagnosis of malignant ascites included positive cytology and results from careful clinical observation for at least 6 mo in patients with negative cytology. The technical success rate, cytology results and complications were evaluated. RESULTS: We found 11 patients who underwent EUS-P with an automated spring-loaded needle device. In 4 cases, ascites was revealed only with EUS but not in other imaging modalities. EUS-P was done in 7 other cases because there was minimal ascitic fluid and no safe window for percutaneous abdominal aspiration. Ascitic fluid was obtained in all cases by EUS-P. The average amount aspirated was 14.1 mL (range 0.5-38 mL) and that was sent for cytological exam. The etiology of ascitic fluid was benign in 5 patients and malignant in 6. In all cases, ascitic fluid was obtained with the first needle pass. No procedure-related adverse effects occurred. CONCLUSION: EUS-P with an automated spring-loaded needle device is a feasible and safe method for ascites evaluation. PMID:24567793

  13. Performance of Single-Use FlexorVue vs Reusable BoaVision Ureteroscope for Visualization of Calices and Stone Extraction in an Artificial Kidney Model.

    PubMed

    Schlager, Daniel; Hein, Simon; Obaid, Moaaz Abdulghani; Wilhelm, Konrad; Miernik, Arkadiusz; Schoenthaler, Martin

    2017-11-01

    To evaluate and compare Flexor ® Vue™, a semidisposable endoscopic deflection system with disposable ureteral sheath and reusable visualization source, and a nondisposable fiber optic ureteroscope in a standard in vitro setting. FlexorVue and a reusable fiber optic flexible ureteroscope were each tested in an artificial kidney model. The experimental setup included the visualization of colored pearls and the extraction of calculi with two different extraction devices (NCircle ® and NGage ® ). The procedures were performed by six experienced surgeons. Visualization time, access to calices, successful stone retraction, and time required were recorded. In addition, the surgeons' workload and subjective performance were determined according to the National Aeronautics and Space Administration-task load index (NASA-TLX). We referred to the Likert scale to assess maneuverability, handling, and image quality. Nearly all calices (99%) were correctly identified using the reusable scope, indicating full kidney access, whereas 74% of the calices were visualized using FlexorVue, of which 81% were correctly identified. Access to the lower poles of the kidney model was significantly less likely with the disposable device, and time to completion was significantly longer (755 s vs 153 s, p < 0.001). The stone clearance success rate with the disposable device was 23% using the NGage and 13% using the NCircle basket. Overall NASA-TLX scores were significantly higher using FlexorVue. The conventional reusable device also demonstrated superior maneuverability, handling, and image quality. FlexorVue offers a semidisposable deflecting endoscopic system allowing basic ureteroscopic and cystoscopic procedures. For its use as an addition or replacement for current reusable scopes, it requires substantial technical improvements.

  14. [Critical assessment of a new endoscopic anatomic concept for the so-called cardia in the sense of the notions of Parmenides and Martin Heidegger].

    PubMed

    Riegler, M; Asari, R; Cosentini, E P; Wrba, F; Schoppmann, S F

    2014-04-01

    Current endoscopic anatomy interposes the gastric cardia between the tubular oesophagus and the proximal stomach. In contrast to that, recent evidence unfolds a different view. Using "PubMed" and "Scopus" searches, we examined if the novel understanding regarding the cardia goes in line with the concept of unfolding, as described by Heidegger based on the ancient didactic poetry of Parmenides. What has been taken as gastric cardia in fact represents reflux-damaged, dilated, columnar lined oesophagus (CLO): dilated distal oesophagus (DDO). Due to its macroscopic gastric appearance it cannot be discriminated from the stomach by endoscopy. Differentiation between DDE and proximal stomach requires the histopathology of measured multi-level biopsies obtained from the DDO and the proximal stomach. Cardaic, onxytocardiac mucosa and intestinal metaplasia (IM; Barrett's oesophagus) define CLO and thus the oesophageal location, while oxyntic mucosa (OM) of the proximal stomach verifies a gastric biopsy location. Endoscopically visible CLO and DDO define the morphological manifestation of reflux: the squamo-oxyntic gap (SOG). Biopsies obtained from the level of the diaphragmatic impressions allow differentiation between an enlarged hiatus with normal anatomic content (CLO; oesophagus) vs. hernia with abnormal content (OM; stomach). Non-dysplastic Barrett's oesophagus exists in 10 %-17 % of asymptomatic and in 20 %-100 % (with increasing CLO length) of reflux symptom-positive individuals (annual cancer risk: 0.2 %-0.7 %). These data justify biopsy of an endoscopically normal appearing squamocolumnar junction for the exclusion of Barrett's oesophagus and cancer risk. In the absence of contraindications, cancer risk-based therapy of dysplastic Barrett's oesophagus includes radiofrequency ablation (RFA) ± endoscopic resection. The perception of the cardia as reflux damaged DDO mirrors the concept of unfolding, as described by the interpretation of the didactic poem of Parmenides by Heidegger. Our data recommend to omit the term "cardia" and allocate morphology either to the oesophagus (CLO, DDO) or to the proximal stomach or indicate that allocation is impossible (i. e.. tumour-induced). Future studies will have to test the value of this novel concept for diagnosis, treatment of gastro-oesophageal reflux disease and cancer prevention. © Georg Thieme Verlag KG Stuttgart · New York.

  15. Relationship between stent characteristics and treatment outcomes in endoscopic transmural drainage of uncomplicated pancreatic pseudocysts.

    PubMed

    Bang, Ji Young; Wilcox, C Mel; Trevino, Jessica M; Ramesh, Jayapal; Hasan, Muhammad; Hawes, Robert H; Varadarajulu, Shyam

    2014-10-01

    Transmural stents are placed at endoscopy to drain pancreatic fluid collections. This study evaluated the relationship between stent placement and treatment outcomes in patients undergoing endoscopic transmural drainage of uncomplicated pancreatic pseudocysts. This is a retrospective study of all patients who underwent endoscopic drainage of uncomplicated pancreatic pseudocysts over a 10-year period. After dilating the transmural tracts in the range of 8-15 mm, single or multiple, 7 or 10Fr double-pigtail plastic stents were deployed. The main outcome measure was to evaluate the relationship between stent characteristics and the number of endoscopic interventions required to achieve resolution of the pancreatic pseudocyst (treatment success). Of 122 patients, 45 (36.9%) had 10Fr stents of which 30 patients (66.7%) had more than one stent; the remaining 77 (63.1%) patients had 7Fr stents of which 56 (72.7%) had more than one stent. The overall treatment success was 94.3%. Treatment was successful in 102 patients (83.6%) with one intervention; 13 patients (10.7%) required re-intervention for successful drainage and 7 patients (5.7%) failed endoscopic treatment. There was no significant difference in the number of interventions required for treatment success between patients with 7 or 10Fr stents (one intervention required in 87.7 vs. 90.5%, respectively; p = 0.766) and between patients with 1 or >1 stent (one intervention required in 88.9 vs. 88.6%, respectively; p = 0.999). On multiple logistic regression analysis, the stent size (OR 1.54; 95% CI 0.23-10.4) and number (OR 1.15; 95% CI 0.25-5.25) were not associated with the number of interventions required for treatment success when adjusted for pseudocyst size, location, drainage modality, the presence or absence of pancreatic duct stent and luminal compression. There appears to be no relationship between the number of interventions required for treatment success and stent characteristics in patients undergoing endoscopic transmural drainage of uncomplicated pancreatic pseudocysts.

  16. Outcomes after endoscopic port surgery for spontaneous intracerebral hematomas.

    PubMed

    Ochalski, Pawel; Chivukula, Srinivas; Shin, Samuel; Prevedello, Daniel; Engh, Johnathan

    2014-05-01

    Spontaneous intracerebral hemorrhages (ICHs) cause significant morbidity and mortality. Traditional open surgical management strategies offer limited benefit except for the most superficial hemorrhages in select patients. Recent reports suggest that endoscopic approaches may improve outcomes, particularly for deep subcortical hemorrhages. However, the management of these patients remains controversial. We reviewed our experience using endoscopic port surgery to identify characteristics that may predict acceptable outcomes. We completed a retrospective chart and imaging review of patients who underwent endoscopic port surgery for evacuation of spontaneous ICH at a single center. Data were gathered regarding patient demographics, hemorrhage locations, operative findings, and clinical outcomes. From 2007 to 2011, 18 patients underwent evacuation of spontaneous intracerebral hematomas using an endoscopic port. The mean age in years was 62 years (range, 43-84 years). Six of 18 patients (33%) died before discharge, and 2 others (11%) died after at least 1 month of survival. Of 12 initial survivors, all were discharged to a rehabilitation or nursing facility. Complete hematoma evacuation was achieved in 7 of 18 patients, with the remaining 11 having a partial evacuation. The patients who died (n = 6) before discharge were statistically more likely to have a left-sided hemorrhage, partial evacuation, or older age than the survivors; death at least 1  month after evacuation was additionally associated with greater preoperative hematoma volumes. Our series demonstrates that endoscopic port surgery for acute intracerebral hematoma evacuation has the ability to achieve significant decompression of large and deep-seated hematomas. Patient age, extent of evacuation, laterality, and preoperative hematoma volume appear to influence patient outcome. Most overall outcomes remain poor. Future studies are necessary to determine if surgical evacuation is in fact superior to best medical treatment and if so, to validate, refute, or further identify characteristics that define surgical candidates. Georg Thieme Verlag KG Stuttgart · New York.

  17. Open Approaches to the Anterior Skull Base in Children: Review of the Literature.

    PubMed

    Wasserzug, Oshri; DeRowe, Ari; Ringel, Barak; Fishman, Gadi; Fliss, Dan M

    2018-02-01

    Introduction  Skull base lesions in children and adolescents are rare, and comprise only 5.6% of all skull base surgery. Anterior skull base lesions dominate, averaging slightly more than 50% of the cases. Until recently, surgery of the anterior skull base was dominated by open procedures and endoscopic skull base surgery was reserved for benign pathologies. Endoscopic skull base surgery is gradually gaining popularity. In spite of that, open skull base surgery is still considered the "gold standard" for the treatment of anterior skull base lesions, and it is the preferred approach in selected cases. Objective  This article reviews current concepts and open approaches to the anterior skull base in children in the era of endoscopic surgery. Materials and Methods  Comprehensive literature review. Results  Extensive intracranial-intradural invasion, extensive orbital invasion, encasement of the optic nerve or the internal carotid artery, lateral supraorbital dural involvement and involvement of the anterior table of the frontal sinus or lateral portion of the frontal sinus precludes endoscopic surgery, and mandates open skull base surgery. The open approaches which are used most frequently for surgical resection of anterior skull base tumors are the transfacial/transmaxillary, subcranial, and subfrontal approaches. Reconstruction of anterior skull base defects is discussed in a separate article in this supplement. Discussion  Although endoscopic skull base surgery in children is gaining popularity in developed countries, in many cases open surgery is still required. In addition, in developing countries, which accounts for more than 80% of the world's population, limited access to expensive equipment precludes the use of endoscopic surgery. Several open surgical approaches are still employed to resect anterior skull base lesions in the pediatric population. With this large armamentarium of surgical approaches, tailoring the most suitable approach to a specific lesion in regard to its nature, location, and extent is of utmost importance.

  18. Robotic transanal endoscopic microsurgery: technical details for the lateral approach.

    PubMed

    Buchs, Nicolas C; Pugin, François; Volonte, Francesco; Hagen, Monika E; Morel, Philippe; Ris, Frederic

    2013-10-01

    Transanal endoscopic microsurgery is a minimally invasive approach reserved for the resection of selected rectal tumors. However, this approach is technically demanding. Although robotic technology may overcome the limitations of this approach, the system can be difficult to dock, especially in the lithotomy position. The study aim is thus to report the technical details of robotic transanal endoscopic microsurgery with the use of a lateral approach. This study is a prospective evaluation of robotic transanal endoscopic microsurgery in a single tertiary institution, under a protocol approved by our local ethics committee. Patients underwent a routine mechanical bowel preparation and were placed in the left or right lateral position according to the tumor location. A circular anal dilatator was used together with the glove port technique. The robotic system was then docked over the hip. A 30° optic and 2 articulated instruments were used with an additional assistant trocar. The tumor excision was realized with an atraumatic grasper and an articulated cautery hook, and the defect was closed with barbed continuous stiches in each case. The primary outcome was the safety and feasibility of the procedure. Three patients underwent a robotic transanal endoscopic microsurgery with the use of the lateral approach. Mean operative time was 110 minutes, including 20 minutes for the docking of the robot. There was 1 intraoperative complication (a pneumoperitoneum without intraabdominal lesion) and no postoperative complications. Mean hospital stay was 3 days. Margins were negative in all the cases. The study was limited by the small number of patients. Robotic transanal endoscopic microsurgery with use of the lateral approach is feasible and may facilitate the local resection of small lesions of the mid and lower rectum. It might assume an important place in sphincter-preserving surgery, especially for selected and early rectal cancer (see Video, Supplemental Digital Content 1, http://links.lww.com/DCR/A114).

  19. Combined endoscopy, aspiration, and biopsy analysis for identifying infectious colitis in patients with ileocecal ulcers.

    PubMed

    Nagata, Naoyoshi; Shimbo, Takuro; Sekine, Katsunori; Tanaka, Shouhei; Niikura, Ryota; Mezaki, Kazuhisa; Morino, Eriko; Yazaki, Hirohisa; Igari, Toru; Ohmagari, Norio; Akiyama, Junichi; Oka, Shinichi; Uemura, Naomi

    2013-06-01

    The ileocecal area is commonly involved in infection and inflammatory colonic diseases, but differential diagnosis can be difficult. We identified definitive endoscopic findings and a sample collection method for diagnosing infectious colitis. In a retrospective study, we analyzed data on 128 patients with ileocecal ulcer who underwent colonoscopy from 2007-2011 at the National Center for Global Health and Medicine in Tokyo, Japan. We collected information on location, size, number, and distinctive endoscopic findings and estimated diagnostic odds ratios (ORs). The sensitivities of microscopy, culture, polymerase chain reaction, and histologic methods in identifying patients with infection were compared with those of standard stool, endoscopic aspirated intestinal fluid, or biopsy analyses. Of the 128 patients, 100 had infections, and 28 had Crohn's disease, Behçet's disease, or other inflammatory diseases. Predictive endoscopic findings were as follows: for amebiasis of the cecum (OR, 17.8), with exudates (OR, 13.9) and round-shaped ulcer (OR, 5.77); for tuberculosis (TB) with transverse-shaped ulcer (OR, 175), scar (OR, 34.6), linear-shaped ulcer (OR, 23.9), or ≥10 mm (OR, 14.0); for cytomegalovirus with round-shaped ulcer (OR, 4.09); and for Campylobacter with cecal valve lesion (OR, 58.3) or ≥10 mm (OR, 10.4). The sensitivity of endoscopic sample collection was significantly higher than that of standard stool sample collection for the diagnosis of amebiasis, TB, non-TB mycobacteria, and other bacteria (P < .05). The methods that detected infection with the highest levels of sensitivity were biopsy with histology for amebiasis, biopsy with culture for TB, biopsy with polymerase chain reaction for cytomegalovirus, and aspiration of intestinal fluid with culture for Campylobacter. Combining results from endoscopic analysis with appropriate sample collection and pathogen detection methods enables infectious colitis to be differentiated from other noninfectious colonic diseases. Copyright © 2013 AGA Institute. Published by Elsevier Inc. All rights reserved.

  20. SU-C-18A-02: Image-Based Camera Tracking: Towards Registration of Endoscopic Video to CT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ingram, S; Rao, A; Wendt, R

    Purpose: Endoscopic examinations are routinely performed on head and neck and esophageal cancer patients. However, these images are underutilized for radiation therapy because there is currently no way to register them to a CT of the patient. The purpose of this work is to develop a method to track the motion of an endoscope within a structure using images from standard clinical equipment. This method will be incorporated into a broader endoscopy/CT registration framework. Methods: We developed a software algorithm to track the motion of an endoscope within an arbitrary structure. We computed frame-to-frame rotation and translation of the cameramore » by tracking surface points across the video sequence and utilizing two-camera epipolar geometry. The resulting 3D camera path was used to recover the surrounding structure via triangulation methods. We tested this algorithm on a rigid cylindrical phantom with a pattern spray-painted on the inside. We did not constrain the motion of the endoscope while recording, and we did not constrain our measurements using the known structure of the phantom. Results: Our software algorithm can successfully track the general motion of the endoscope as it moves through the phantom. However, our preliminary data do not show a high degree of accuracy in the triangulation of 3D point locations. More rigorous data will be presented at the annual meeting. Conclusion: Image-based camera tracking is a promising method for endoscopy/CT image registration, and it requires only standard clinical equipment. It is one of two major components needed to achieve endoscopy/CT registration, the second of which is tying the camera path to absolute patient geometry. In addition to this second component, future work will focus on validating our camera tracking algorithm in the presence of clinical imaging features such as patient motion, erratic camera motion, and dynamic scene illumination.« less

  1. Do you have what it takes for challenging endoscopic submucosal dissection cases?

    PubMed Central

    Kim, Kyoung-Oh; Kim, Sung Jung; Kim, Tae Hyeon; Park, Jong-Jae

    2011-01-01

    Endoscopic submucosal dissection (ESD) is a widely accepted treatment for early gastric cancer (EGC), especially in Korea and Japan. The criteria for the therapeutic use of ESD for EGC have been expanded recently. However, attention should be drawn to the technical feasibility of the ESD treatment which depends on a lesion’s location, size or fibrosis level, or operator’s experience. In the case of a lesion with a high level of difficulty, a more experienced operator is required. Thus, the treatment for a lesion with a high level of difficulty should be performed according to the degree of the operator’s experience. In this paper, the authors describe the ESD procedure for lesions with a high level of difficulty. PMID:21987603

  2. [Intestinal volvulus caused by the ingestion of magnet balls: unexpected risk in children].

    PubMed

    Kubačková, D; Nosek, J; Třeška, V; Vacek, V; Pizingerová, K

    2015-05-01

    The occurrence of swallowed foreign bodies in the digestive system is a common problem in children with the highest incidence in children aged six months to five years. Most swallowed objects leave the human body per vias naturales while 10-20% of swallowed foreign bodies need to be removed with an endoscope. Serious and life-threatening situations are caused by the ingestion of foreign bodies in about 1% of all cases. The authors present a case of a two-year-old girl diagnosed with acute abdomen for which she was operated on. A small bowel volvulus and several intestinal fistulas were found intraoperatively. The cause of this finding was the ingestion of magnetic balls and a swallowed metal body drawn to them by magnetic force. If more than one magnetic body is ingested, it is necessary to admit the patient to hospital and to remove these foreign bodies using an endoscope. The position of the magnets which is not changing in a location inaccessible for an endoscope during 2448 hours is an indication for urgent operation.

  3. Treatment of a unicameral bone cyst of calcaneus with endoscopic curettage and percutaneous filling with corticocancellous allograft.

    PubMed

    Yildirim, Cengiz; Mahiroğullari, Mahir; Kuşkucu, Mesih; Akmaz, Ibrahim; Keklikci, Kenan

    2010-01-01

    The surgical procedures for unicameral solitary calcaneal bone cysts have ranged from simple curettage and grafting to subperiosteal resection with internal fixation and grafting. In this article, an endoscopically assisted technique is proposed for the curettage of a simple calcaneal cyst that takes advantage of direct visualization of the cyst wall and contents and permits accurate assessment of the extent of the lesion. After curettage, percutaneous filling of the defect with corticocancellous allograft makes the technique a complete, minimally invasive surgical approach for this condition. The technique uses 2 lateral portals, one for viewing and the other for manipulation, both of which are created under fluoroscopic control. Once the cyst has been located, the 30 degrees arthroscope is used to evacuate fluid, after which more solid cyst contents are fragmented and removed. Thereafter, curettage of the inner surface of the cavernous cyst wall is performed. Finally, complete packing of the previously cystic cavity with crushed corticocancellous allograft is performed under endoscopic visualization and confirmed radiographically. Copyright 2010 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  4. Non-exposed endoscopic wall-inversion surgery for gastrointestinal stromal tumor

    PubMed Central

    Mitsui, Takashi; Aikou, Susumu; Niimi, Keiko; Fujishiro, Mitsuhiro; Seto, Yasuyuki

    2018-01-01

    Laparoscopic and endoscopic cooperative surgery (LECS) is an accepted method of laparoscopic wedge resection, which is minimally invasive, for gastrointestinal stromal tumors (GISTs). We established a type of LECS achieving a full-thickness resection, non-exposed endoscopic wall-inversion surgery (NEWS), in an effort to prevent exposure of the peritoneal cavity to gastric intraluminal contents. We employed this surgical technique in 28 gastric GIST patients. We failed to complete NEWS in the initial two patients and in one patient with a large tumor (40 mm × 35 mm), but otherwise carried out the procedure successfully. Although a learning effect is speculated to occur, based on a decreasing trend in the operation time, the median operation time was 184 minutes showing that NEWS is still a time-consuming method. No significant differences were recognized in tumor size or location, except near the esophagogastric junction (EGJ), nor in the cross-sectional circumference. NEWS is feasible and appears to be a good option, especially for small GISTs with mucosal ulceration rendering full-thickness enucleation by opening of the gastric wall unfeasible. PMID:29682624

  5. Inter and intra-observer concordance for the diagnosis of portal hypertension gastropathy.

    PubMed

    Casas, Meritxell; Vergara, Mercedes; Brullet, Enric; Junquera, Félix; Martínez-Bauer, Eva; Miquel, Mireia; Sánchez-Delgado, Jordi; Dalmau, Blai; Campo, Rafael; Calvet, Xavier

    2018-03-01

    At present there is no fully accepted endoscopic classification for the assessment of the severity of portal hypertensive gastropathy (PHG). Few studies have evaluated inter and intra-observer concordance or the degree of concordance between different endoscopic classifications. To evaluate inter and intra-observer agreement for the presence of portal hypertensive gastropathy and enteropathy using different endoscopic classifications. Patients with liver cirrhosis were included into the study. Enteroscopy was performed under sedation. The location of lesions and their severity was recorded. Images were videotaped and subsequently evaluated independently by three different endoscopists, one of whom was the initial endoscopist. The agreement between observations was assessed using the kappa index. Seventy-four patients (mean age 63.2 years, 53 males and 21 females) were included. The agreement between the three endoscopists regarding the presence or absence of PHG using the Tanoue and McCormack classifications was very low (kappa scores = 0.16 and 0.27, respectively). The current classifications of portal hypertensive gastropathy have a very low degree of intra and inter-observer agreement for the diagnosis and assessment of gastropathy severity.

  6. Antigravity ESD - double-balloon-assisted underwater with traction hybrid technique.

    PubMed

    Sharma, Sam K; Hiratsuka, Takahiro; Hara, Hisashi; Milsom, Jeffrey W

    2018-06-01

     Complex colorectal polyps or those positioned in difficult anatomic locations are an endoscopic therapeutic challenge. Underwater endoscopic submucosal dissection (UESD) is a potential technical solution to facilitate efficient polyp removal. In addition, endoscopic tissue retraction has been confined to limited methods of varying efficacy and complexity. The aim of this study was to evaluate the efficiency of a unique UESD technique for removing complex polyps using double-balloon-assisted retraction (R).  Using fresh ex-vivo porcine rectum, 4-cm polyps were created using electrosurgery and positioned at "6 o'clock" within an established ESD model. Six resections were performed in each group. Underwater techniques were facilitated using a novel double-balloon platform (Dilumen, Lumendi, Westport, Connecticut, United States).  UESD-R had a significantly shorter total procedural time than cap-assisted ESD and UESD alone (24 vs. 58 vs. 56 mins). UESD-R produced a dissection time on average of 5 minutes, attributed to the retraction provided. There was also a subjective significant reduction in electrosurgical smoke with the underwater techniques contributing to improved visualization.  Here we report the first ex-vivo experience of a unique double-balloon endoscopic platform optimized for UESD with tissue traction capability. UESD-R removed complex lesions in significantly shorter time than conventional means. The combined benefits of UESD and retraction appeared to be additive when tackling complex polyps and should be studied further.

  7. Effect of Incremental Endoscopic Maxillectomy on Surgical Exposure of the Pterygopalatine and Infratemporal Fossae.

    PubMed

    Upadhyay, Smita; Dolci, Ricardo L L; Buohliqah, Lamia; Fiore, Mariano E; Ditzel Filho, Leo F S; Prevedello, Daniel M; Otto, Bradley A; Carrau, Ricardo L

    2016-02-01

    Objective Access to the pterygopalatine and infratemporal fossae presents a significant surgical challenge, owing to their deep-seated location and complex neurovascular anatomy. This study elucidates the benefits of incremental medial maxillectomies to access this region. We compared access to the medial aspect of the infratemporal fossa provided by medial maxillectomy, anteriorly extended medial maxillectomy, endoscopic Denker approach (i.e., Sturmann-Canfield approach), contralateral transseptal approach, and the sublabial anterior maxillotomy (SAM). Methods We studied 10 cadaveric specimens (20 sides) dissecting the pterygopalatine and infratemporal fossae bilaterally. Radius of access was calculated using a navigation probe aligned with the endoscopic line of sight. Area of exposure was calculated as the area removed from the posterior wall of maxillary sinus. Surgical freedom was calculated by computing the working area at the proximal end of the instrument with the distal end fixed at a target. Results The endoscopic Denker approach offered a superior area of exposure (8.46 ± 1.56 cm(2)) and superior surgical freedom. Degree of lateral access with the SAM approach was similar to that of the Denker. Conclusion Our study suggests that an anterior extension of the medial maxillectomy or a cross-court approach increases both the area of exposure and surgical freedom. Further increases can be seen upon progression to a Denker approach.

  8. Effect of Incremental Endoscopic Maxillectomy on Surgical Exposure of the Pterygopalatine and Infratemporal Fossae

    PubMed Central

    Upadhyay, Smita; Dolci, Ricardo L. L.; Buohliqah, Lamia; Fiore, Mariano E.; Filho, Leo F.S. Ditzel; Prevedello, Daniel M.; Otto, Bradley A.; Carrau, Ricardo L.

    2015-01-01

    Objective Access to the pterygopalatine and infratemporal fossae presents a significant surgical challenge, owing to their deep-seated location and complex neurovascular anatomy. This study elucidates the benefits of incremental medial maxillectomies to access this region. We compared access to the medial aspect of the infratemporal fossa provided by medial maxillectomy, anteriorly extended medial maxillectomy, endoscopic Denker approach (i.e., Sturmann-Canfield approach), contralateral transseptal approach, and the sublabial anterior maxillotomy (SAM). Methods We studied 10 cadaveric specimens (20 sides) dissecting the pterygopalatine and infratemporal fossae bilaterally. Radius of access was calculated using a navigation probe aligned with the endoscopic line of sight. Area of exposure was calculated as the area removed from the posterior wall of maxillary sinus. Surgical freedom was calculated by computing the working area at the proximal end of the instrument with the distal end fixed at a target. Results The endoscopic Denker approach offered a superior area of exposure (8.46 ± 1.56 cm2) and superior surgical freedom. Degree of lateral access with the SAM approach was similar to that of the Denker. Conclusion Our study suggests that an anterior extension of the medial maxillectomy or a cross-court approach increases both the area of exposure and surgical freedom. Further increases can be seen upon progression to a Denker approach. PMID:26949591

  9. Assessment of test methods for evaluating effectiveness of cleaning flexible endoscopes.

    PubMed

    Washburn, Rebecca E; Pietsch, Jennifer J

    2018-06-01

    Strict adherence to each step of reprocessing is imperative to removing potentially infectious agents. Multiple methods for verifying proper reprocessing exist; however, each presents challenges and limitations, and best practice within the industry has not been established. Our goal was to evaluate endoscope cleaning verification tests with particular interest in the evaluation of the manual cleaning step. The results of the cleaning verification tests were compared with microbial culturing to see if a positive cleaning verification test would be predictive of microbial growth. This study was conducted at 2 high-volume endoscopy units within a multisite health care system. Each of the 90 endoscopes were tested for adenosine triphosphate, protein, microbial growth via agar plate, and rapid gram-negative culture via assay. The endoscopes were tested in 3 locations: the instrument channel, control knob, and elevator mechanism. This analysis showed substantial level of agreement between protein detection postmanual cleaning and protein detection post-high-level disinfection at the control head for scopes sampled sequentially. This study suggests that if protein is detected postmanual cleaning, there is a significant likelihood that protein will also be detected post-high-level disinfection. It also infers that a cleaning verification test is not predictive of microbial growth. Copyright © 2018 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  10. Emergency endoscopic needle-knife precut papillotomy in acute severe cholangitis resulting from impacted common bile duct stones at duodenal papilla.

    PubMed

    Zheng, Mingwei; Liu, Xufeng; Li, Ning; Li, Wei-Zhi

    2018-03-01

    To evaluate the efficacy and safety of emergency endoscopic needle-knife precut papillotomy in acute severe cholangitis resulting from impacted common bile duct stones at duodenal papilla. Between January 2010 and January 2015, 118 cases of acute severe cholangitis with impacted common bile duct stones at the native papilla underwent emergency endoscopic retrograde cholangiopancreatography (ERCP) and early needle-knife precut papillotomy in a tertiary referral center. Precut techniques were performed according to the different locations of stones in the duodenal papilla. Clinical data about therapy and recovery of the 118 patients were recorded and analyzed. One hundred and eighteen patients underwent emergency ERCP within 24 h after hospitalization, with a total success rate of 100%. The mean operating time was 6.4 ± 4.1 min. Postoperative acute physiology and chronic health evaluation (APACHE) II scores, white blood cell count and liver function improved significantly. The complication rate was 4.2% (5/118); two with hemorrhage and three with acute pancreatitis. There was no procedure-related mortality. Emergency endoscopic needle-knife precut papillotomy is effective and safe for acute severe cholangitis resulting from impacted common bile duct stones at the duodenal papilla. Copyright © 2017 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  11. Endoscopy-guided balloon dilation of benign anastomotic strictures after radical gastrectomy for gastric cancer.

    PubMed

    Lee, Hyun Jik; Park, Wan; Lee, Hyuk; Lee, Keun Ho; Park, Jun Chul; Shin, Sung Kwan; Lee, Sang Kil; Lee, Yong Chan; Noh, Sung Hoon

    2014-07-01

    The aim of this study was to evaluate the outcome of endoscopic dilation for benign anastomotic stricture after radical gastrectomy in gastric cancer patients. Gastric cancer patients who underwent endoscopic balloon dilation for benign anastomosis stricture after radical gastrectomy during a 6-year period were reviewed retrospectively. Twenty-one patients developed benign strictures at the site of anastomosis. The majority of strictures occurred within 1 year after surgery (95.2%). The median duration to stenosis after surgery was 1.70 months (range, 0.17 to 23.97 months). The success rate of the first endoscopic dilation was 61.9%. Between the restenosis group (n=8) and the no restenosis group (n=13), there were no significant differences in the body mass index (22.82 kg/m(2) vs 22.46 kg/m(2)), interval to symptom onset (73.9 days vs 109.3 days), interval to treatment (84.6 days vs 115.6 days), maximal balloon diameter (14.12 mm vs 15.62 mm), number of balloon dilation sessions (1.75 vs 1.31), location of gastric cancer or type of surgery. One patient required surgery because of stricture refractory to repeated dilation. Endoscopic dilation is a highly effective treatment for benign anastomotic strictures after radical gastrectomy for gastric cancer and should be considered a primary intervention prior to proceeding with surgical revision.

  12. Accuracy of colonoscopy in localizing colonic cancer.

    PubMed

    Stanciu, C; Trifan, Anca; Khder, Saad Alla

    2007-01-01

    It is important to establish the precise localization of colonic cancer preoperatively; while colonoscopy is regarded as the diagnostic gold standard for colorectal cancer, its ability to localize the tumor is less reliable. To define the accuracy of colonoscopy in identifying the location of colonic cancer. All of the patients who had a colorectal cancer diagnosed by colonoscopy at the Institute of Gastroenterology and Hepatology, Iaşi and subsequently received a surgical intervention at three teaching hospitals in Iaşi, between January 2001 and December 2005, were included in this study. Endoscopic records and operative notes were carefully reviewed, and tumor localization was recorded. There were 161 patients (89 men, 72 women, aged 61.3 +/- 12.8 years) who underwent conventional surgery for colon cancer detected by colonoscopy during the study period. Twenty-two patients (13.66%) had erroneous colonoscopic localization of the tumors. The overall accuracy of preoperative colonoscopic localization was 87.58%. Colonoscopy is an accurate, reliable method for locating colon cancer, although additional techniques (i.e., endoscopic tattooing) should be performed at least for small lesions.

  13. 21 CFR 886.4400 - Electronic metal locator.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Electronic metal locator. 886.4400 Section 886...) MEDICAL DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4400 Electronic metal locator. (a) Identification. An electronic metal locator is an AC-powered device with probes intended to locate metallic...

  14. 21 CFR 886.4400 - Electronic metal locator.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Electronic metal locator. 886.4400 Section 886...) MEDICAL DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4400 Electronic metal locator. (a) Identification. An electronic metal locator is an AC-powered device with probes intended to locate metallic...

  15. 21 CFR 886.4400 - Electronic metal locator.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Electronic metal locator. 886.4400 Section 886...) MEDICAL DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4400 Electronic metal locator. (a) Identification. An electronic metal locator is an AC-powered device with probes intended to locate metallic...

  16. 21 CFR 886.4400 - Electronic metal locator.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Electronic metal locator. 886.4400 Section 886...) MEDICAL DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4400 Electronic metal locator. (a) Identification. An electronic metal locator is an AC-powered device with probes intended to locate metallic...

  17. 21 CFR 886.4400 - Electronic metal locator.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Electronic metal locator. 886.4400 Section 886...) MEDICAL DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4400 Electronic metal locator. (a) Identification. An electronic metal locator is an AC-powered device with probes intended to locate metallic...

  18. High pressure jet injection of viscous solutions for endoscopic submucosal dissection (ESD): first clinical experience.

    PubMed

    Pioche, Mathieu; Lépilliez, Vincent; Déprez, Pierre; Giovannini, Marc; Caillol, Fabrice; Piessevaux, Hubert; Rivory, Jérôme; Guillaud, Olivier; Ciocîrlan, Mihai; Salmon, Damien; Lienhart, Isabelle; Lafon, Cyril; Saurin, Jean-Christophe; Ponchon, Thierry

    2015-08-01

    Long lasting elevation is a key factor during endoscopic submucosal dissection (ESD) and can be obtained by water jet injection of saline solution or by viscous macromolecular solutions. In a previous animal study, we assessed the Nestis Enki II system to combine jet injection and viscous solutions. In the present work, we used this combination in humans in different sites of the digestive tract. We retrospectively report all of the consecutive ESD procedures performed with jet injection of viscous solutions in four centers. Information was collected about the lesion, the procedure, the histological result, and the outcomes for the patient. In total, 45 resections were completed by six operators: five experts and one beginner with only one previous experience in human ESD. Lesions were located in the esophagus (10), the stomach (11), the duodenum (1), the colon (1) and the rectum (22). Average maximal lesion diameter was 4.8 cm (SD 2.4, range 2 - 11 cm), average lesion surface area was 19.8 cm(2) (SD 17.7, range 2.2 - 72 cm(2)), and average duration of procedure was 79.9 min (SD 50.3 min, range 19 - 225 min). ESD could be conducted while the endoscope was retroflexed at its maximum in 26 cases. Four adverse events were observed: two diminutive perforations and two delayed bleeding occurrences treated conservatively. The R0 resection rate was 91.1 %. The catheter was obstructed in six occurrences of bleeding. Endoscopic submucosal dissection using high pressure injection of viscous macromolecular solutions is safe and effective in different parts of the digestive tract. It does not impede working with the endoscope in the maximal retroflexed position.

  19. Stent induced gastric wall erosion and endoscopic retrieval of nonadjustable gastric band: a new technique.

    PubMed

    Wilson, Todd D; Miller, Nathan; Brown, Nicholas; Snyder, Brad E; Wilson, Erik B

    2013-05-01

    In gastrointestinal surgery, specifically in bariatric surgery, there are many types of fixed bands used for restriction and there are a multitude reasons that might eventually be an impetus for the removal of those bands. Bands consisting of Marlex or non silastic materials can be extremely difficult to remove. Intraoperative complications removing fixed bands include the difficulty in locating the band, inability to remove all of the band, and damage to surrounding structures including gastrotomies. Removal of eroded bands endoscopically may pose less risk. Potentially, forced erosion may be an easier modality than surgery, allowing revision without having to deal with the actual band at the time of definitive revision surgery. A retrospective case series developed from a university single institution bariatric practice setting was utilized. Endpoints for the study include success of band removal, complications, length of time the stent was present, and the type of stent. A total of 15 consecutive cases utilizing endoscopic stenting to actively induce fixed gastric band erosion for subsequent endoscopic removal were reviewed. There was an 87 % success rate in complete band removal with partial removal of the remaining bands that resolved the patient's symptoms. A complication rate of 27 % was recorded among the 15 patients, consisting of pain and/or nausea and vomiting. The mean time period of the placement of the stent prior to removal or attempted removal was 16.3 days. Endoscopic forced erosion of fixed gastric bands is feasible, safe, and may offer an advantage over laparoscopic removal. This technique is especially applicable for gastric obstruction from fixed bands, prior to large and definitive revision surgeries, or anticipated hostile anatomy that might preclude an abdominal operation altogether.

  20. Massive Atenolol, Lisinopril, and Chlorthalidone Overdose Treated with Endoscopic Decontamination, Hemodialysis, Impella Percutaneous Left Ventricular Assist Device, and ECMO.

    PubMed

    Heise, C William; Beutler, David; Bosak, Adam; Orme, Geoffrey; Loli, Akil; Graeme, Kimberlie

    2015-03-01

    Overdose of cardiovascular medications is increasingly associated with morbidity and mortality. We present a case of substantial atenolol, chlorthalidone, and lisinopril overdose treated by multiple modalities with an excellent outcome. Aggressive medical intervention did not provide sufficient hemodynamic stability in this patient with refractory cardiogenic and distributive shock. Impella® percutaneous left ventricular assist device and extracorporeal membrane oxygenation provided support while the effects of the overdose subsided. We present concentrations demonstrating removal of atenolol with continuous venovenous hemodiafiltration. This is the first report of esophagogastroduo denoscopy decontamination of this overdose with a large pill fragment burden.

  1. Colonoscopic Removal of an Intrauterine Device That Had Perforated the Rectosigmoid Colon

    PubMed Central

    Huh, Jin Myeong; Kim, Ki Seok; Cho, Yong Seok; Lee, Jae Uk; Baek, Seong Deuk; Moon, Sin Kil

    2018-01-01

    The intrauterine device (IUD) is a widely used contraceptive method. One of the most serious and rare complications of using an IUD is colon perforation. We report a case of colonoscopic removal of an IUD that had perforated into the rectosigmoid colon in a 42-year-old woman who presented with no symptoms. Colonoscopy showed that the IUD had penetrated into rectosigmoid colon wall and that an arm of the IUD was embedded in the colon wall. We were able to remove the IUD easily by using colonoscopy. The endoscopic approach may be considered the first choice therapy for selected patients. PMID:29742863

  2. Moving mobile: using an open-sourced framework to enable a web-based health application on touch devices.

    PubMed

    Lindsay, Joseph; McLean, J Allen; Bains, Amrita; Ying, Tom; Kuo, M H

    2013-01-01

    Computer devices using touch-enabled technology are becoming more prevalent today. The application of a touch screen high definition surgical monitor could allow not only high definition video from an endoscopic camera to be displayed, but also the display and interaction with relevant patient and health related data. However, this technology has not been quickly embraced by all health care organizations. Although traditional keyboard or mouse-based software programs may function flawlessly on a touch-based device, many are not practical due to the usage of small buttons, fonts and very complex menu systems. This paper describes an approach taken to overcome these problems. A real case study was used to demonstrate the novelty and efficiency of the proposed method.

  3. Neurostimulation of the Gastrointestinal Tract: Review of Recent Developments

    PubMed Central

    Abell, Thomas L.; Chen, Jiande; Emmanuel, Anton; Jolley, Christopher; Sarela, Abeezar I.; Törnblom, Hans

    2015-01-01

    Neurostimulation is one manifestation of neuromodulation of the gastrointestinal (GI) tract. This manuscript reviews the history of neurostimulation of the GI tract with emphasis on current methods of stimulation. Upper GI disorders can be modulated with both temporary (placed endoscopically or surgically) or permanent (placed surgically) gastric electrical stimulation (GES) devices. The current gastrointestinal (GI) neurostimulation of stomach (GES) devices have been used in both children and adults and some patients have been followed in excess of 15 years with good long-term results. Similar GES devices have also been used for a variety of lower GI disorders, including constipation and fecal incontinence, for a number of years. Based on these recent developments, the future uses of neurostimulation in the GI tract are discussed with an emphasis on new applications and innovations. PMID:25581846

  4. Possibilities and limitations of current stereo-endoscopy.

    PubMed

    Mueller-Richter, U D A; Limberger, A; Weber, P; Ruprecht, K W; Spitzer, W; Schilling, M

    2004-06-01

    Stereo-endoscopy has become a commonly used technology. In many comparative studies striking advantages of stereo-endoscopy over two-dimensional presentation could not be proven. To show the potential and fields for further improvement of this technology is the aim of this article. The physiological basis of three-dimensional vision limitations of current stereo-endoscopes is discussed and fields for further research are indicated. New developments in spatial picture acquisition and spatial picture presentation are discussed. Current limitations of stereo-endoscopy that prevent a better ranking in comparative studies with two-dimensional presentation are mainly based on insufficient picture acquisition. Devices for three-dimensional picture presentation are at a more advanced developmental stage than devices for three-dimensional picture acquisition. Further research should emphasize the development of new devices for three-dimensional picture acquisition.

  5. Image-guided biopsy in the esophagus through comprehensive optical frequency domain imaging and laser marking: a study in living swine.

    PubMed

    Suter, Melissa J; Jillella, Priyanka A; Vakoc, Benjamin J; Halpern, Elkan F; Mino-Kenudson, Mari; Lauwers, Gregory Y; Bouma, Brett E; Nishioka, Norman S; Tearney, Guillermo J

    2010-02-01

    Random biopsy esophageal surveillance can be subject to sampling errors, resulting in diagnostic uncertainty. Optical frequency domain imaging (OFDI) is a high-speed, 3-dimensional endoscopic microscopy technique. When deployed through a balloon-centering catheter, OFDI can automatically image the entire distal esophagus (6.0 cm length) in approximately 2 minutes. To test a new platform for guided biopsy that allows the operator to select target regions of interest on an OFDI dataset, and then use a laser to mark the esophagus at corresponding locations. The specific goals include determining the optimal laser parameters, testing the accuracy of the laser marking process, evaluating the endoscopic visibility of the laser marks, and assessing the amount of mucosal damage produced by the laser. Experimental study conducted in 5 swine in vivo. Massachusetts General Hospital. Success rate, including endoscopic visibility of laser marks and accuracy of the laser marking process for selected target sites, and extent of the thermal damage caused by the laser marks. All of the laser-induced marks were visible by endoscopy. Target locations were correctly marked with a success rate of 97.07% (95% confidence interval, 89.8%-99.7%). Thermal damage was limited to the superficial layers of the mucosa and was observed to partially heal within 2 days. An animal study with artificially placed targets to simulate pathology. The study demonstrates that laser marking of esophageal sites identified in comprehensive OFDI datasets is feasible and can be performed with sufficient accuracy, precision, and visibility to guide biopsy in vivo.

  6. New laser soldering-based closures: a promising method in natural orifice transluminal endoscopic surgery.

    PubMed

    Bogni, Serge; Ortner, Maria-Anna; Vajtai, Istvan; Jost, Christian; Reinert, Michael; Dallemagne, Bernard; Frenz, Martin

    2012-07-01

    Complete closure of gastrotomy is the linchpin of safe natural orifice transgastric endoscopic surgery. To evaluate feasibility and efficacy of a new method of gastrotomy closure by using a sutureless laser tissue-soldering (LTS) technique in an ex vivo porcine stomach. In vitro experiment. Experimental laboratory. Histological analysis and internal and external liquid pressure with and without hydrochloric acid exposure were determined comparing gastrotomy closure with LTS and with hand-sewn surgical sutures. Comparison of LTS and hand-sewn surgical gastrotomy closure. The primary outcome parameter was the internal leak pressure. Secondary parameters were the difference between internal and external leak pressures, the impact of an acid environment on the device, histological changes, and feasibility of endoscopic placement. The internal liquid leak pressure after LTS was almost twice as high as after hand-sewn surgical closure (416 ± 53 mm Hg vs 229 ± 99 mm Hg; P = .01). The internal leak pressure (416 ± 53 mm Hg) after LTS was higher than the external leak pressure (154 ± 46 mm Hg; P < .0001). An acidic environment did not affect leak pressure after LTS. Endoscopic LTS closure was feasible in all experiments. Histopathology revealed only slight alterations beneath the soldering plug. In vitro experiments. Leak pressure after LTS closure of gastrotomy is higher than after hand-sewn surgical closure. LTS is a promising technique for closure of gastrotomies and iatrogenic perforations. Further experiments, in particular survival studies, are mandatory. Copyright © 2012 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  7. Deformation Cycling of a Ti - Ni Alloy with Superelasticity Effect Applied in Cardiology

    NASA Astrophysics Data System (ADS)

    Kaputkin, D. E.; Morozova, T. V.

    2014-07-01

    The study concerns the effect of the conditions and of the force of loading experienced by an implanted device from a Ti - Ni alloy during its transfer to the working zone, for example, in endoscopic implantation into the coronary sinus of the greater vena cava of heart. It is shown that preliminary deformation cycling (10 - 15 cycles) stabilizes the set of mechanical properties of the alloy.

  8. Wireless fluorescence capsule for endoscopy using single photon-based detection

    NASA Astrophysics Data System (ADS)

    Al-Rawhani, Mohammed A.; Beeley, James; Cumming, David R. S.

    2015-12-01

    Fluorescence Imaging (FI) is a powerful technique in biological science and clinical medicine. Current FI devices that are used either for in-vivo or in-vitro studies are expensive, bulky and consume substantial power, confining the technique to laboratories and hospital examination rooms. Here we present a miniaturised wireless fluorescence endoscope capsule with low power consumption that will pave the way for future FI systems and applications. With enhanced sensitivity compared to existing technology we have demonstrated that the capsule can be successfully used to image tissue autofluorescence and targeted fluorescence via fluorophore labelling of tissues. The capsule incorporates a state-of-the-art complementary metal oxide semiconductor single photon avalanche detector imaging array, miniaturised optical isolation, wireless technology and low power design. When in use the capsule consumes only 30.9 mW, and deploys very low-level 468 nm illumination. The device has the potential to replace highly power-hungry intrusive optical fibre based endoscopes and to extend the range of clinical examination below the duodenum. To demonstrate the performance of our capsule, we imaged fluorescence phantoms incorporating principal tissue fluorophores (flavins) and absorbers (haemoglobin). We also demonstrated the utility of marker identification by imaging a 20 μM fluorescein isothiocyanate (FITC) labelling solution on mammalian tissue.

  9. The role of endoscopic therapy in obesity management: intragastric balloons and aspiration therapy.

    PubMed

    Kumar, Nitin; Sullivan, Shelby; Thompson, Christopher C

    2017-01-01

    Weight management is increasingly incorporating endoscopic bariatric therapy (EBT). As the global burden of obesity and its comorbidities has increased, it is evident that novel therapeutic approaches will be necessary to address the obesity epidemic. EBTs offer greater efficacy than diet and lifestyle modification and lower invasiveness than bariatric surgery. The US Food and Drug Administration has approved two intragastric balloons and aspiration therapy for the treatment of obesity: Apollo Orbera is indicated for the treatment of Class I and Class II obesity, Re Shape Integrated Dual Balloon system is indicated for the same range with a comorbidity, and Aspire Bariatrics AspireAssist is approved for patients with a body mass index of 35-55 kg/m 2 . These devices have proven safe and effective in clinical trials and are gaining commercial acceptance in the USA; the Orbera has been used extensively outside the USA for over 20 years. These devices will need to be delivered in the context of a multidisciplinary weight loss program, integrating comprehensive care of obesity. Patient selection is important, and ensuring appropriate patient expectations and understanding of alternatives such as pharmacologic therapy and surgery is essential. With several EBTs on the horizon, patients with obesity will have an even broader array of safe and effective options for weight management in the future.

  10. Wireless powering for a self-propelled and steerable endoscopic capsule for stomach inspection.

    PubMed

    Carta, R; Tortora, G; Thoné, J; Lenaerts, B; Valdastri, P; Menciassi, A; Dario, P; Puers, R

    2009-12-15

    This paper describes the integration of an active locomotion module in a wirelessly powered endoscopic capsule. The device is a submersible capsule optimized to operate in a fluid environment in a liquid-distended stomach. A 3D inductive link is used to supply up to 400mW to the embedded electronics and a set of 4 radio-controlled motor propellers. The design takes advantage of a ferrite-core in the receiving coil-set. This approach significantly improves the coupling with the external field source with respect to earlier work by the group. It doubles the power that can be received with a coreless coil-set under identical external conditions. The upper limit of the received power was achieved complying with the strict regulations for safe exposure of biological tissue to variable magnetic fields. The wireless transferred power was proven to be sufficient to achieve the speed of 7cm/s in any directions. An optimized locomotion strategy was defined which limits the power consumption by running only 2 motors at a time. A user interface and a joystick controller allow to fully drive the capsule in an intuitive manner. The device functionalities were successfully tested in a dry and a wet environment in a laboratory set-up.

  11. Gastrointestinal Bleeding Following LVAD Placement from Top to Bottom.

    PubMed

    Cushing, Kelly; Kushnir, Vladimir

    2016-06-01

    Left ventricular assist devices (LVADs) are an increasingly prevalent form of mechanical support for patients with end-stage heart failure. These devices can be implanted both as a bridge to transplant and as definitive/destination therapy. Gastrointestinal (GI) bleeding is one of the most common and recalcitrant long-term complications following LVAD implantation, with an incidence approaching 30 %. This review will discuss what is known about the pathophysiology of GI bleeding in LVADs and the currently available options for medical and/or endoscopic management. The pathophysiology of bleeding is multifactorial, with hemodynamic alterations, acquired von Willebrand factor deficiency, and coagulopathy being most often implicated. The majority of bleeding events in this population result from angioectasias and gastroduodenal erosive disease. While these bleeding events are significant and often require transfusion therapy, they are rarely life threatening. Endoscopy remains the standard of care with upper endoscopy offering the highest diagnostic yield in these patients. However, the effectiveness of endoscopic hemostasis in this population is not well established. A small number of studies have evaluated medical therapy and alterations in LVAD settings as a means of preventing or treating bleeding with variable results. In summary, GI bleeding with LVADs is a common occurrence and will continue to be as more LVADs are being performed for destination therapy.

  12. Endoscopic submucosal dissection for esophageal squamous cell neoplasms.

    PubMed

    Fujishiro, Mitsuhiro; Kodashima, Shinya; Goto, Osamu; Ono, Satoshi; Niimi, Keiko; Yamamichi, Nobutake; Oka, Masashi; Ichinose, Masao; Omata, Masao

    2009-04-01

    Endoscopic submucosal dissection (ESD) has gradually gained acceptance as one of the standard treatments for early esophageal cancer, as well as for early gastric cancer in Japan, but standardization of the knowledge is still incomplete. The final goal to perform ESD is not to resect the lesion in an en bloc fashion, but to save the patient from esophageal cancer-related death. Thus, the indications should be considered based on the entire patient, not just the target lesion itself, and pre-, peri- and postoperative management of the patient is also very important, as well as technical aspects of ESD. In terms of the techniques of ESD, owing to refinement of the procedural strategy, invention of the devices, and the learning curve, acceptable safety and favorable middle-term efficacy have been obtained. We believe that ESD will become a standard treatment for early esophageal cancer not only in Japan but also worldwide in the near future.

  13. Advances in endoscopic balloon therapy for weight loss and its limitations

    PubMed Central

    Vyas, Dinesh; Deshpande, Kaivalya; Pandya, Yagnik

    2017-01-01

    The field of medical and surgical weight loss is undergoing an explosion of new techniques and devices. A lot of these are geared towards endoscopic approaches rather than the conventional and more invasive laparoscopic or open approach. One such recent advance is the introduction of intrgastric balloons. In this article, we discuss the recently Food and Drug Administration approved following balloons for weight loss: the Orbera™ Intragastric Balloon System (Apollo Endosurgery Inc, Austin, TX, United States), the ReShape® Integrated Dual Balloon System (ReShape Medical, Inc., San Clemente, CA, United States), and the Obalon (Obalon® Therapeutics, Inc.). The individual features of each of these balloons, the method of introduction and removal, and the expected weight loss and possible complications are discussed. This review of the various balloons highlights the innovation in the field of weight loss. PMID:29209122

  14. Natural orifice translumenal endoscopic surgery (NOTES): emerging trends and specifications for a virtual simulator.

    PubMed

    Schwaitzberg, Steven D; Dorozhkin, Denis; Sankaranarayanan, Ganesh; Matthes, Kai; Jones, Daniel B; De, Suvranu

    2016-01-01

    A virtual translumenal endoscopic surgical trainer (VTEST) is being developed to accelerate the development of natural orifice translumenal endoscopic surgery (NOTES) procedures and devices in a safe and risk-free environment. For a rapidly developing field such as NOTES, a needs analysis must be conducted regularly to discover emerging research trends and areas of potential high impact for a virtual simulator. This paper presents a survey-based study which follows a similar study conducted by this group in 2011 (Sankaranarayanan et al. in Surg Endosc 27:1607-1616, 2013). A 32-point questionnaire was distributed at the 2012 Natural Orifice Surgery Consortium for Assessment and Research annual meeting. These data were subsequently augmented by an identical online survey, targeted at the members of the American Society for Gastrointestinal Endoscopy and the Society of American Gastrointestinal and Endoscopic Surgeons, and analyzed. Twenty-eight NOTES experts participated in the 2012 study. Cholecystectomy (CE) procedure remained the most commonly performed NOTES technique, with 18 positive responses (64%). In contrast to 2011, the popularity of the NOTES appendectomy (AE) was significantly lower, with only 2 (7%) instances (CE vs. AE, p < 0.001), while the number of peroral endoscopic myotomy (POEM, PE) cases had increased significantly, with 11 (39%) positive responses, respectively (PE vs. AE, p = 0.013). Strong preference toward hybrid rather than pure NOTES techniques (82 vs. 11%, p < 0.001) was also expressed. Other responses were similar to those in the 2011 study, with the VTEST™ utility in developing and testing new techniques and instruments ranked particularly high. Based on the results of this study, a decision was made to focus exclusively on the transvaginal hybrid NOTES cholecystectomy procedure, including both rigid and flexible scope techniques. The importance of developing a virtual NOTES simulator was reaffirmed, with POEM identified as a promising candidate for future simulator development.

  15. Endoscopic Sleeve Gastroplasty (ESG) Is a Reproducible and Effective Endoscopic Bariatric Therapy Suitable for Widespread Clinical Adoption: a Large, International Multicenter Study.

    PubMed

    Sartoretto, Adrian; Sui, Zhixian; Hill, Christine; Dunlap, Margo; Rivera, Angielyn R; Khashab, Mouen A; Kalloo, Anthony N; Fayad, Lea; Cheskin, Lawrence J; Marinos, George; Wilson, Erik; Kumbhari, Vivek

    2018-02-15

    Endoscopic sleeve gastroplasty (ESG), an incisionless endoscopic bariatric procedure, has shown impressive results in case series. This study examines the reproducibility, efficacy, and safety in three centers across two countries, and identifies key determinants for procedural success. Patients who underwent ESG between February 2016 and May 2017 at one of three centers (Australia and USA) were retrospectively analyzed. All procedures were performed on an outpatient basis using the Apollo OverStitch device (Apollo Endosurgery, Austin, TX). Primary outcomes included absolute weight loss (ΔWeight, kg), change in body mass index (∆BMI, in kg/m 2 ), total body weight loss (TBWL, %), excess weight loss (EWL, in %), and immediate and delayed adverse events. In total, 112 consecutive patients (male 31%, age 45.1 ± 11.7 years, baseline BMI 37.9 ± 6.7 kg/m 2 ) underwent ESG. At 1, 3, and 6 months, Δweight was 9.0 ± 4.6 kg (TBWL 8.4 ± 4.1%), 12.9 ± 6.4 kg (TBWL 11.9 ± 4.5%), and 16.4 ± 10.7 kg (TBWL 14.9 ± 6.1%), respectively. The proportion of patients who attained greater than 10% TBWL and 25% EWL was 62.2 and 78.0% at 3 months post-ESG and 81.0 and 86.5% at 6 months post-ESG. Weight loss was similar between the three centers. Multivariable analysis showed that male sex, greater baseline body weight, and lack of prior endoscopic bariatric therapy were predictors of greater Δweight at 6 months. Three (2.7%) severe adverse events were observed. ESG is an effective, reproducible, and safe weight loss therapy that is suitable for widespread clinical adoption.

  16. Endoscopic-modified medial maxillectomy and its limitation for a solitary fibrous tumor of the lacrimal sac and nasolacrimal duct.

    PubMed

    Moriyama, Munehito; Kodama, Satoru; Hirano, Takashi; Suzuki, Masashi

    2017-06-01

    Solitary fibrous tumor (SFT) is an uncommon neoplasm that usually arises from the pleura. Recently, SFTs have been reported in the head and neck region located in subsites such as the orbit. SFTs of the lacrimal sac are extremely rare, with only six cases reported in the English literature. We describe a SFT arising from the right lacrimal sac and extending along the nasolacrimal duct into the nasal cavity. Although, the tumor could not be removed by endoscopic-modified medial maxillectomy (EMMM) alone, combined approach with EMMM and a small external incision achieved the complete removal of the tumor. The patient has remained disease-free 24 months after surgery. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  17. Real-time endoscopic guidance using near-infrared fluorescent light for thoracic surgery

    NASA Astrophysics Data System (ADS)

    Venugopal, Vivek; Stockdale, Alan; Neacsu, Florin; Kettenring, Frank; Frangioni, John V.; Gangadharan, Sidharta P.; Gioux, Sylvain

    2013-03-01

    Lung cancer is the leading cause of cancer death in the United States, accounting for 28% of all cancer deaths. Standard of care for potentially curable lung cancer involves preoperative radiographic or invasive staging, followed by surgical resection. With recent adjuvant chemotherapy and radiation studies showing a survival advantage in nodepositive patients, it is crucial to accurately stage these patients surgically in order to identify those who may benefit. However, lymphadenectomy in lung cancer is currently performed without guidance, mainly due to the lack of tools permitting real-time, intraoperative identification of lymph nodes. In this study we report the design and validation of a novel, clinically compatible near-infrared (NIR) fluorescence thoracoscope for real-time intraoperative guidance during lymphadenectomy. A novel, NIR-compatible, clinical rigid endoscope has been designed and fabricated, and coupled to a custom source and a dual channel camera to provide simultaneous color and NIR fluorescence information to the surgeon. The device has been successfully used in conjunction with a safe, FDA-approved fluorescent tracer to detect and resect mediastinal lymph nodes during thoracic surgery on Yorkshire pigs. Taken together, this study lays the foundation for the clinical translation of endoscopic NIR fluorescence intraoperative guidance and has the potential to profoundly impact the management of lung cancer patients.

  18. Endoscopic add-on stiffness probe for real-time soft surface characterisation in MIS.

    PubMed

    Faragasso, A; Stilli, A; Bimbo, J; Noh, Y; Liu, H; Nanayakkara, T; Dasgupta, P; Wurdemann, H A; Althoefer, K

    2014-01-01

    This paper explores a novel stiffness sensor which is mounted on the tip of a laparoscopic camera. The proposed device is able to compute stiffness when interacting with soft surfaces. The sensor can be used in Minimally Invasive Surgery, for instance, to localise tumor tissue which commonly has a higher stiffness when compared to healthy tissue. The purely mechanical sensor structure utilizes the functionality of an endoscopic camera to the maximum by visually analyzing the behavior of trackers within the field of view. Two pairs of spheres (used as easily identifiable features in the camera images) are connected to two springs with known but different spring constants. Four individual indenters attached to the spheres are used to palpate the surface. During palpation, the spheres move linearly towards the objective lens (i.e. the distance between lens and spheres is changing) resulting in variations of their diameters in the camera images. Relating the measured diameters to the different spring constants, a developed mathematical model is able to determine the surface stiffness in real-time. Tests were performed using a surgical endoscope to palpate silicon phantoms presenting different stiffness. Results show that the accuracy of the sensing system developed increases with the softness of the examined tissue.

  19. High-sensitivity, real-time, ratiometric imaging of surface-enhanced Raman scattering nanoparticles with a clinically translatable Raman endoscope device.

    PubMed

    Garai, Ellis; Sensarn, Steven; Zavaleta, Cristina L; Van de Sompel, Dominique; Loewke, Nathan O; Mandella, Michael J; Gambhir, Sanjiv S; Contag, Christopher H

    2013-09-01

    Topical application and quantification of targeted, surface-enhanced Raman scattering (SERS) nanoparticles offer a new technique that has the potential for early detection of epithelial cancers of hollow organs. Although less toxic than intravenous delivery, the additional washing required to remove unbound nanoparticles cannot necessarily eliminate nonspecific pooling. Therefore, we developed a real-time, ratiometric imaging technique to determine the relative concentrations of at least two spectrally unique nanoparticle types, where one serves as a nontargeted control. This approach improves the specific detection of bound, targeted nanoparticles by adjusting for working distance and for any nonspecific accumulation following washing. We engineered hardware and software to acquire SERS signals and ratios in real time and display them via a graphical user interface. We report quantitative, ratiometric imaging with nanoparticles at pM and sub-pM concentrations and at varying working distances, up to 50 mm. Additionally, we discuss optimization of a Raman endoscope by evaluating the effects of lens material and fiber coating on background noise, and theoretically modeling and simulating collection efficiency at various working distances. This work will enable the development of a clinically translatable, noncontact Raman endoscope capable of rapidly scanning large, topographically complex tissue surfaces for small and otherwise hard to detect lesions.

  20. Nonsurgical treatment of actively bleeding internal hemorrhoids with a novel endoscopic device (with video).

    PubMed

    Kantsevoy, Sergey V; Bitner, Marianne

    2013-10-01

    Internal hemorrhoids often present with bleeding, prolapse, and other symptoms. Currently used nonsurgical treatment modalities have limited effectiveness and usually require several treatment sessions. To evaluate effectiveness and safety of a novel endoscopic device for nonsurgical treatment of internal hemorrhoids. Retrospective study. Single center. This study involved 23 patients with actively bleeding internal hemorrhoids. The HET Bipolar System is a modified anoscope, with a treatment window, light source, and tissue temperature monitor. The device is inserted into the rectum under direct observation. The tissue carrying superior hemorrhoidal branches and the apex of the internal hemorrhoid is positioned inside the treatment window, clamped with incorporated tissue forceps, and treated with bipolar energy to ligate hemorrhoidal feeding vessels. Rate of hemorrhoidal bleeding after the treatment. The mean age of the patients was 64.3 ± 9.9 years (range 44-79 years). Eleven patients (47.8%) had grade I hemorrhoids and 12 patients (52.2%) had grade II hemorrhoids. In 18 patients (78.3%), treatment with the HET System was performed with the patient under conscious sedation. Five patients (21.7%) were treated without sedation. All patients tolerated treatment without complaints. The average follow-up period was 11.2 ± 4.7 months. No bleeding or prolapse occurred after the procedure in any of the treated patients. Retrospective study. The newly developed HET System is easy to use, safe, and highly effective in eliminating bleeding in grade I and II internal hemorrhoids and prolapse in grade II internal hemorrhoids. Copyright © 2013 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

Top